Sample records for optical mark reader

  1. Usability of Optical Mark Reader Sheet as an Answering Tool in Testing.

    PubMed

    Booka, Masayuki; Oku, Hidehisa; Scheller, Andreas; Yamaoka, Shintaro

    2017-01-01

    The research result on usability of Optical Mark Reader Sheet (OMRS) being used as the standard answering tool is reported. The use of OMRS significantly requires more answer time than the answer time without OMRS, and the use of assistive devices for OMRS has the possibility to reduce the answer time.

  2. Instruments for Reading Direct-Marked Data-Matrix Symbols

    NASA Technical Reports Server (NTRS)

    Schramm, Harry F.; Corder, Eric L.

    2006-01-01

    Improved optoelectronic instruments (specially configured digital cameras) for reading direct-marked data-matrix symbols on the surfaces of optically reflective objects (including specularly reflective ones) are undergoing development. Data-matrix symbols are two-dimensional binary patterns that are used, like common bar codes, for automated identification of objects. The first data-matrix symbols were checkerboard-like patterns of black-and-white rectangles, typically existing in the forms of paint, ink, or detachable labels. The major advantage of direct marking (the marks are more durable than are painted or printed symbols or detachable labels) is offset by a major disadvantage (the marks generated by some marking methods do not provide sufficient contrast to be readable by optoelectronic instruments designed to read black-and-white data-matrix symbols). Heretofore, elaborate lighting, lensing, and software schemes have been tried in efforts to solve the contrast problem in direct-mark matrix- symbol readers. In comparison with prior readers based on those schemes, the readers now undergoing development are expected to be more effective while costing less. All of the prior direct-mark matrix-symbol readers are designed to be aimed perpendicularly to marked target surfaces, and they tolerate very little angular offset. However, the reader now undergoing development not only tolerates angular offset but depends on angular offset as a means of obtaining the needed contrast, as described below. The prototype reader (see Figure 1) includes an electronic camera in the form of a charge-coupled-device (CCD) image detector equipped with a telecentric lens. It also includes a source of collimated visible light and a source of collimated infrared light for illuminating a target. The visible and infrared illumination complement each other: the visible illumination is more useful for aiming the reader toward a target, while the infrared illumination is more useful for reading symbols on highly reflective surfaces. By use of beam splitters, the visible and infrared collimated lights are introduced along the optical path of the telecentric lens, so that the target is illuminated and viewed from the same direction.

  3. Applications of Optical Scanners in an Academic Center.

    ERIC Educational Resources Information Center

    Molinari, Carol; Tannenbaum, Robert S.

    1995-01-01

    Describes optical scanners, including how the technology works; applications in data management and research; development of instructional materials; and providing community services. Discussion includes the three basic types of optical scanners: optical character recognition (OCR), optical mark readers (OMR), and graphic scanners. A sidebar…

  4. Interfacing Optical Document Scanners: Principles and Practical Considerations.

    ERIC Educational Resources Information Center

    Krus, David J.; Kodimer, Dennis

    1987-01-01

    Handlers for interfacing the ScanTron and 2700 Optical Mark Readers with the IBM AT/XT/PC and Tandy 2000/1000/3000 iAPX 88/186/286 based computers were described. Differences between programing an RS232C serial port using BIOS interrupts and directly addressing the Motorola 8550 ART microprocessor were discussed. (Author/LMO)

  5. Trends in OMR Techniques and Equipment.

    ERIC Educational Resources Information Center

    Ward, Obie; Poulos, Cynthia

    Various aspects of the Optical Mark Reader (OMR) used by the Atlanta Public School System are discussed. First considered are the required features of the OMR scanner. Following this, methods of motivating users to record data accurately are described. Finally, a description of how forms are designed for the convenience of users is provided. (PB)

  6. Desktop system for accounting, audit, and research in A&E.

    PubMed Central

    Taylor, C J; Brain, S G; Bull, F; Crosby, A C; Ferguson, D G

    1997-01-01

    The development of a database for audit, research, and accounting in accident and emergency (A&E) is described. The system uses a desktop computer, an optical scanner, sophisticated optical mark reader software, and workload management data. The system is highly flexible, easy to use, and at a cost of around 16,000 pounds affordable for larger departments wishing to move towards accounting. For smaller departments, it may be an alternative to full computerisation. Images Figure 1 Figure 2 Figure 3 Figure 5 Figure 6 PMID:9132200

  7. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT.

    PubMed

    Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P

    2013-01-01

    The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p < 0.001), part-solid nodules (97% vs 81%, p = 0.0027), and GGO nodules (82% vs 69%, p < 0.001) for all readers (p < 0.001). Respective sensitivities for reader(thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p < 0.001), and 77% (p < 0.001) for solid nodules; 72%, 73% (p = 0.322), and 94% (p < 0.001) for part-solid nodules; and 53%, 58% (p = 0.008), and 79% (p < 0.001) for GGO nodules. For reader(thin), false-positives increased from 0.64 per case to 0.90 with CAD(thin) (p < 0.001) but not for reader(thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.

  8. A Novel Marking Reader for Progressive Addition Lenses Based on Gabor Holography.

    PubMed

    Perucho, Beatriz; Picazo-Bueno, José Angel; Micó, Vicente

    2016-05-01

    Progressive addition lenses (PALs) are marked with permanent engraved marks (PEMs) at standardized locations. Permanent engraved marks are very useful through the manufacturing and mounting processes, act as locator marks to re-ink the removable marks, and contain useful information about the PAL. However, PEMs are often faint and weak, obscured by scratches, partially occluded, and difficult to recognize on tinted lenses or with antireflection or scratch-resistant coatings. The aim of this article is to present a new generation of portable marking reader based on an extremely simplified concept for visualization and identification of PEMs in PALs. Permanent engraved marks on different PALs are visualized using classical Gabor holography as underlying principle. Gabor holography allows phase sample visualization with adjustable magnification and can be implemented in either classical or digital versions. Here, visual Gabor holography is used to provide a magnified defocused image of the PEMs onto a translucent visualization screen where the PEM is clearly identified. Different types of PALs (conventional, personalized, old and scratched, sunglasses, etc.) have been tested to visualize PEMs with the proposed marking reader. The PEMs are visible in every case, and variable magnification factor can be achieved simply moving up and down the PAL in the instrument. In addition, a second illumination wavelength is also tested, showing the applicability of this novel marking reader for different illuminations. A new concept of marking reader ophthalmic instrument has been presented and validated in the laboratory. The configuration involves only a commercial-grade laser diode and a visualization screen for PEM identification. The instrument is portable, economic, and easy to use, and it can be used for identifying patient's current PAL model and for marking removable PALs again or finding test points regardless of the age of the PAL, its scratches, tints, or coatings.

  9. Low-cost and high-speed optical mark reader based on an intelligent line camera

    NASA Astrophysics Data System (ADS)

    Hussmann, Stephan; Chan, Leona; Fung, Celine; Albrecht, Martin

    2003-08-01

    Optical Mark Recognition (OMR) is thoroughly reliable and highly efficient provided that high standards are maintained at both the planning and implementation stages. It is necessary to ensure that OMR forms are designed with due attention to data integrity checks, the best use is made of features built into the OMR, used data integrity is checked before the data is processed and data is validated before it is processed. This paper describes the design and implementation of an OMR prototype system for marking multiple-choice tests automatically. Parameter testing is carried out before the platform and the multiple-choice answer sheet has been designed. Position recognition and position verification methods have been developed and implemented in an intelligent line scan camera. The position recognition process is implemented into a Field Programmable Gate Array (FPGA), whereas the verification process is implemented into a micro-controller. The verified results are then sent to the Graphical User Interface (GUI) for answers checking and statistical analysis. At the end of the paper the proposed OMR system will be compared with commercially available system on the market.

  10. AN OPTICAL CHARACTER RECOGNITION RESEARCH AND DEMONSTRATION PROJECT.

    ERIC Educational Resources Information Center

    1968

    RESEARCH AND DEVELOPMENT OF PROTOTYPE LIBRARY SYSTEMS WHICH UTILIZE OPTICAL CHARACTER RECOGNITION INPUT HAS CENTERED AROUND OPTICAL PAGE READERS AND DOCUMENT READERS. THE STATE-OF-THE-ART OF BOTH THESE OPTICAL SCANNERS IS SUCH THAT BOTH ARE ACCEPTABLE FOR LIBRARY INPUT PREPARATION. A DEMONSTRATION PROJECT UTILIZING THE TWO TYPES OF READERS, SINCE…

  11. Agreement among readers on what is relevant in self-help psychology books.

    PubMed

    Forest, James J; Del Ben, Kevin; Toews, Stuart B

    2003-12-01

    It was hypothesized that text marking in self-help psychology books would indicate that readers agree on which pages and lines contain relevant information. Previously owned copies of two self-help book titles (n=48, n=38), all with marked text, were collected from second-hand book stores and scored for line and page marking. Chi-squares for goodness-of-fit yielded significant differences between observed and chance agreement in marking behavior. Intraclass and KR-20 correlations were significantly different from zero, suggesting that readers agreed on what information was relevant and irrelevant. Actual users of self-help books may have similar standards because of cultural values, social group relations, or common problem experiences.

  12. An affordable optically stimulated luminescent dosimeter reader utilizing multiple excitation wavelengths.

    PubMed

    Kearfott, Kimberlee J; West, W Geoffrey

    2015-10-01

    A lower-cost optically stimulated luminescence (OSL) reader with increased flexibility for pursuing laboratory research into OSL theory and application was designed and constructed. This was achieved by using off-the-shelf optical components and higher-power light emitting diodes. The resulting reader includes more wavelengths of excitation light than current commercial readers, as well as the ability to swap out filters and other components during an experiment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. When transparency is opaque: Effects of diacritic marks and vowel letters on dyslexic Hebrew readers.

    PubMed

    Weiss, Yael; Katzir, Tami; Bitan, Tali

    2016-10-01

    The current study examined the effects of orthographic transparency and familiarity on brain mechanisms involved in word recognition in adult dyslexic Hebrew readers. We compared functional Magnetic Resonance Imaging (fMRI) brain activation in 21 dyslexic readers and 22 typical readers, and examined the effects of diacritic marks that provide transparent but less familiar information and vowel letters that increase orthographic transparency without compromising familiarity. Dyslexic readers demonstrated reduced activation in left supramarginal gyrus (SMG) as compared to typical readers, as well as different patterns of activation within the left inferior frontal gyrus (IFG). Furthermore, in contrast to typical readers, dyslexic readers did not show increased activation for diacritics in left temporo-parietal junction regions, associated with mapping orthography to phonology. Nevertheless, both groups showed the facilitation effect of vowel letters on regions associated with lexical-semantic access. Altogether the results suggest that while typical readers can compensate for the reduced familiarity of pointed words with increased reliance on decoding of smaller units, dyslexic readers do not, and therefore they show a higher cost. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Development of a Handheld Line Information Reader and Generator for Efficient Management of Optical Communication Lines

    PubMed Central

    Lee, Jaeyul; Kwon, Hyungwoo; Song, Jaewon; Jeon, Mansik; Kim, Jeehyun

    2017-01-01

    A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines. PMID:28837058

  15. A Structural Perspective on Readout of Epigenetic Histone and DNA Methylation Marks

    PubMed Central

    Patel, Dinshaw J.

    2016-01-01

    SUMMARY This article outlines the protein modules that target methylated lysine histone marks and 5mC DNA marks, and the molecular principles underlying recognition. The article focuses on the structural basis underlying readout of isolated marks by single reader molecules, as well as multivalent readout of multiple marks by linked reader cassettes at the histone tail and nucleosome level. Additional topics addressed include the role of histone mimics, cross talk between histone marks, technological developments at the genome-wide level, advances using chemical biology approaches, the linkage between histone and DNA methylation, the role for regulatory lncRNAs, and the promise of chromatin-based therapeutic modalities. PMID:26931326

  16. Esophageal-guided biopsy with volumetric laser endomicroscopy and laser cautery marking: a pilot clinical study.

    PubMed

    Suter, Melissa J; Gora, Michalina J; Lauwers, Gregory Y; Arnason, Thomas; Sauk, Jenny; Gallagher, Kevin A; Kava, Lauren; Tan, Khay M; Soomro, Amna R; Gallagher, Timothy P; Gardecki, Joseph A; Bouma, Brett E; Rosenberg, Mireille; Nishioka, Norman S; Tearney, Guillermo J

    2014-06-01

    Biopsy surveillance protocols for the assessment of Barrett's esophagus can be subject to sampling errors, resulting in diagnostic uncertainty. Optical coherence tomography is a cross-sectional imaging technique that can be used to conduct volumetric laser endomicroscopy (VLE) of the entire distal esophagus. We have developed a biopsy guidance platform that places endoscopically visible marks at VLE-determined biopsy sites. The objective of this study was to demonstrate in human participants the safety and feasibility of VLE-guided biopsy in vivo. A pilot feasibility study. Massachusetts General Hospital. A total of 22 participants were enrolled from January 2011 to June 2012 with a prior diagnosis of Barrett's esophagus. Twelve participants were used to optimize the laser marking parameters and the system platform. A total of 30 target sites were selected and marked in real-time by using the VLE-guided biopsy platform in the remaining 10 participants. Volumetric laser endomicroscopy. Endoscopic and VLE visibility, and accuracy of VLE diagnosis of the tissue between the laser cautery marks. There were no adverse events of VLE and laser marking. The optimal laser marking parameters were determined to be 2 seconds at 410 mW, with a mark separation of 6 mm. All marks made with these parameters were visible on endoscopy and VLE. The accuracies for diagnosing tissue in between the laser cautery marks by independent blinded readers for endoscopy were 67% (95% confidence interval [CI], 47%-83%), for VLE intent-to-biopsy images 93% (95% CI, 78%-99%), and for corrected VLE post-marking images 100% when compared with histopathology interpretations. This is a single-center feasibility study with a limited number of patients. Our results demonstrate that VLE-guided biopsy of the esophagus is safe and can be used to guide biopsy site selection based on the acquired volumetric optical coherence tomography imaging data. ( NCT01439633.). Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  17. Esophageal-guided biopsy with volumetric laser endomicroscopy and laser cautery marking: a pilot clinical study

    PubMed Central

    Suter, Melissa J.; Gora, Michalina J.; Lauwers, Gregory Y.; Arnason, Thomas; Sauk, Jenny; Gallagher, Kevin A.; Kava, Lauren; Tan, Khay M.; Soomro, Amna R.; Gallagher, Timothy P.; Gardecki, Joseph A.; Bouma, Brett E.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2018-01-01

    Background Biopsy surveillance protocols for the assessment of Barrett’s esophagus can be subject to sampling errors, resulting in diagnostic uncertainty. Optical coherence tomography is a cross-sectional imaging technique that can be used to conduct volumetric laser endomicroscopy (VLE) of the entire distal esophagus. We have developed a biopsy guidance platform that places endoscopically visible marks at VLE-determined biopsy sites. Objective The objective of this study was to demonstrate in human participants the safety and feasibility of VLE-guided biopsy in vivo. Design A pilot feasibility study. Setting Massachusetts General Hospital. Patients A total of 22 participants were enrolled from January 2011 to June 2012 with a prior diagnosis of Barrett’s esophagus. Twelve participants were used to optimize the laser marking parameters and the system platform. A total of 30 target sites were selected and marked in real-time by using the VLE-guided biopsy platform in the remaining 10 participants. Intervention Volumetric laser endomicroscopy. Main Outcome Measurements Endoscopic and VLE visibility, and accuracy of VLE diagnosis of the tissue between the laser cautery marks. Results There were no adverse events of VLE and laser marking. The optimal laser marking parameters were determined to be 2 seconds at 410 mW, with a mark separation of 6 mm. All marks made with these parameters were visible on endoscopy and VLE. The accuracies for diagnosing tissue in between the laser cautery marks by independent blinded readers for endoscopy were 67% (95% confidence interval [CI], 47%–83%), for VLE intent-to-biopsy images 93% (95% CI, 78%–99%), and for corrected VLE post-marking images 100% when compared with histopathology interpretations. Limitations This is a single-center feasibility study with a limited number of patients. Conclusion Our results demonstrate that VLE-guided biopsy of the esophagus is safe and can be used to guide biopsy site selection based on the acquired volumetric optical coherence tomography imaging data. (Clinical trial registration number: NCT01439633.) PMID:24462171

  18. Appropriating Apocalyptic: Paul Ricoeur's Hermeneutics and the Discourse of Mark 13

    ERIC Educational Resources Information Center

    de Vries, Peter C.

    2010-01-01

    Mark 13 predicts that certain events will occur literally within the generation of Jesus' contemporaries, and today's reader recognizes that some of these events have not taken place. The reader therefore appropriates the text as a false configuration of the world because it describes the world differently from how it is. However, the hermeneutics…

  19. Using Twitter to Teach Reader-Oriented Biblical Interpretation: "Tweading" the Gospel of Mark

    ERIC Educational Resources Information Center

    Williamson, Robert, Jr.

    2013-01-01

    Twitter offers an engaging way to introduce students to reader-oriented interpretation of the Bible. The exercise described here introduces students to the idea that the reader has a role in the production of a text's meaning, which thus varies from reader to reader. Twitter enables us to capture the real-time thoughts of a variety of…

  20. Where to Put the Manicules: A Theory of Expert Reading

    ERIC Educational Resources Information Center

    Horning, Alice S.

    2011-01-01

    Manicules are hand-drawn symbols used by medieval readers to mark important parts of a text. Knowing where to place manicules is one characteristic of an expert reader. A meta-cognitive theory of expert reading helps to account for what readers know that allows them to place manicules appropriately. This theory proposes that expert readers are…

  1. Laser marking on soda-lime glass by laser-induced backside wet etching with two-beam interference

    NASA Astrophysics Data System (ADS)

    Nakazumi, Tomoka; Sato, Tadatake; Narazaki, Aiko; Niino, Hiroyuki

    2016-09-01

    For crack-free marking of glass materials, a beam-scanning laser-induced backside wet etching (LIBWE) process by a beam spot with a fine periodic structure was examined. The fine periodic structure was produced within a beam spot by means of a Mach-Zehnder interferometer incorporated to the optical setup for the beam-scanning LIBWE. A fine structure with a period of 9 µm was observed within the microstructures with a diameter of ca. 40 µm fabricated by a laser shot under double-beam irradiation, and they could be homogeneously fabricated within an area of 800  ×  800 µm. The area filled with the microstructures, including fine periodic structures, could be observed in high contrast under a diffuse, on-axis illumination that was used in commercial QR code readers.

  2. Ultra low-cost, portable smartphone optosensors for mobile point-of-care diagnostics

    NASA Astrophysics Data System (ADS)

    Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei

    2018-02-01

    Smartphone optosensors with integrated optical components make mobile point-of-care (MPoC) diagnostics be done near patients' side. It'll especially have a significant impact on healthcare delivery in rural or remote areas. Current FDA-approved PoC devices achieving clinical level are still at high cost and not affordable in rural hospitals. We present a series of ultra low-cost smartphone optical sensing devices for mobile point-of-care diagnosis. Aiming different targeting analytes and sensing mechanisms, we developed custom required optical components for each smartphone optosensros. These optical devices include spectrum readers, colorimetric readers for microplate, lateral flow device readers, and chemiluminescence readers. By integrating our unique designed optical components into smartphone optosening platform, the anlaytes can be precisely detected. Clinical testing results show the clinical usability of our smartphone optosensors. Ultra low-cost portable smartphone optosensors are affordable for rural/remote doctors.

  3. Breaking off Engagement: Readers' Disengagement as a Function of Reader and Text Characteristics

    ERIC Educational Resources Information Center

    Goedecke, Patricia J.; Dong, Daqi; Shi, Genghu; Feng, Shi; Risko, Evan; Olney, Andrew M.; D'Mello, Sidney K.; Graesser, Arthur C.

    2015-01-01

    Engagement during reading can be measured by the amount of time readers invest in the reading process. It is hypothesized that disengagement is marked by a decrease in time investment as compared with the demands made on the reader by the text. In this study, self-paced reading times for screens of text were predicted by a text complexity score…

  4. Optical benchmarking of security document readers for automated border control

    NASA Astrophysics Data System (ADS)

    Valentín, Kristián.; Wild, Peter; Å tolc, Svorad; Daubner, Franz; Clabian, Markus

    2016-10-01

    Authentication and optical verification of travel documents upon crossing borders is of utmost importance for national security. Understanding the workflow and different approaches to ICAO 9303 travel document scanning in passport readers, as well as highlighting normalization issues and designing new methods to achieve better harmonization across inspection devices are key steps for the development of more effective and efficient next- generation passport inspection. This paper presents a survey of state-of-the-art document inspection systems, showcasing results of a document reader challenge investigating 9 devices with regards to optical characteristics.

  5. Development Of The Drexler Optical-Card Reader/Writer System

    NASA Astrophysics Data System (ADS)

    Pierce, Gerald A.

    1988-06-01

    An optical-card reader/writer optical and electronic breadboard system, developed by SRI International under contract to Drexler Technology, is described. The optical card, which is the same size as a credit card, can contain more than 2 megabytes of digital user data, which may also include preformatted tracking information and preformatted data. The data layout on the card is similar to that on a floppy disk, with each track containing a header and clocking information. The design of this optical reader/writer system for optical cards is explained. Design of the optical card system entails a number of unique issues: To accommodate both laser-recorded and mass-duplicated information, the system must be compatible with preencoded information, which implies a larger-than-normal spot size (5 gm) and a detection system that can read both types of optical patterns. Cost-reduction considerations led to selection of a birefringent protection layer, which dictated a nonstandard optical system. The non-polarization-sensitive optics use an off-axis approach to detection. An LED illumination system makes it possible to read multiple tracks.

  6. A comparison of ROC inferred from FROC and conventional ROC

    NASA Astrophysics Data System (ADS)

    McEntee, Mark F.; Littlefair, Stephen; Pietrzyk, Mariusz W.

    2014-03-01

    This study aims to determine whether receiver operating characteristic (ROC) scores inferred from free-response receiver operating characteristic (FROC) were equivalent to conventional ROC scores for the same readers and cases. Forty-five examining radiologists of the American Board of Radiology independently reviewed 47 PA chest radiographs under at least two conditions. Thirty-seven cases had abnormal findings and 10 cases had normal findings. Half the readers were asked to first locate any visualized lung nodules, mark them and assign a level of confidence [the FROC mark-rating pair] and second give an overall to the entire image on the same scale [the ROC score]. The second half of readers gave the ROC rating first followed by the FROC mark-rating pairs. A normal image was represented with number 1 and malignant lesions with numbers 2-5. A jackknife free-response receiver operating characteristic (JAFROC), and inferred ROC (infROC) was calculated from the mark-rating pairs using JAFROC V4.1 software. ROC based on the overall rating of the image calculated using DBM MRMC software, which was also used to compare infROC and ROC AUCs treating the methods as modalities. Pearson's correlations coefficient and linear regression were used to examine their relationship using SPSS, version 21.0; (SPSS, Chicago, IL). The results of this study showed no significant difference between the ROC and Inferred ROC AUCs (p≤0.25). While Pearson's correlation coefficient was 0.7 (p≤0.01). Inter-reader correlation calculated from Obuchowski- Rockette covariance's ranged from 0.43-0.86 while intra-reader agreement was greater than previously reported ranging from 0.68-0.82.

  7. Assessing operating characteristics of CAD algorithms in the absence of a gold standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.

    2010-04-15

    Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range ofmore » operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.« less

  8. Comparison of reading and listening-reading techniques for administration of PIAT Reading Comprehension subtest: justification for the bypass approach.

    PubMed

    Weinberg, W A; McLean, A; Brumback, R A

    1988-04-01

    The Peabody Individual Achievement Test (PIAT) Reading Comprehension subtest was administered to a group of 23 learning disabled children in Grades 5 through 7 who had been classified by the clinical Lexical Paradigm as good readers or poor readers. Using standardized test administration, 14 poor readers scored substantially below the 9 good readers; however, when the child was allowed to listen and read silently while the test item was read aloud, poor readers showed marked improvement in performance compared to only moderate improvement shown by the good readers. This difference in improvement between the groups was significant and resulted in poor readers achieving performance similar to that of the good readers administered the test in the standard manner.

  9. Inter-method agreement in retinal blood vessels diameter analysis between Dynamic Vessel Analyzer and optical coherence tomography.

    PubMed

    Benatti, Lucia; Corvi, Federico; Tomasso, Livia; Mercuri, Stefano; Querques, Lea; Ricceri, Fulvio; Bandello, Francesco; Querques, Giuseppe

    2017-06-01

    To analyze the inter-methods agreement in arteriovenous ratio (AVR) evaluation between spectral-domain optical coherence tomography (SD-OCT) and Dynamic Vessel Analyzer (DVA). Healthy volunteers underwent DVA and SD-OCT examination. AVR was measured by SD-OCT using the four external lines of the optic nerve head-centered 7-line cube and by DVA using an automated AVR estimation. The mean AVR was calculated, twice, separately by two independent readers for each tool. Twenty-two eyes of 11 healthy subjects (five women and six men, mean age 35) were included. AVR analysis by DVA showed high inter-observer agreement between reader 1 and 2, and high intra-observer agreement for both reader 1 and reader 2. With regard to AVR analysis on SD-OCT, we found high inter-observer agreement between reader 1 and 2, and low intra-observer agreement for reader 2 but high intra-observer agreement for reader 1. Overall, the mean AVR measured on SD-OCT turned out to be significantly higher than mean AVR measured through DVA (reader 1, 0.9023 ± 0.06 vs 0.8036 ± 0.08; p < 0.001, and reader 2, 0.9067 ± 0.06 vs 0.8083 ± 0.05; p= 0.003). No inter-method agreement in AVR could be detected in the present study due to bias in measurements (shift between DVA and SD-OCT). We found significant difference in the two noninvasive methods for AVR measurement, with a tendency for SD-OCT to overestimate retinal vascular caliber in comparison to DVA. This may be useful for achieving greater accuracy in the evaluation of retinal vessel in ocular as well as systemic diseases.

  10. Comparison of Automated Analysis of Cirrus HD-OCT™ Spectral Domain Optical Coherence Tomography with Stereo Photos of the Optic Disc

    PubMed Central

    Sharma, Ashish; Oakley, Jonathan D.; Schiffman, Joyce C.; Budenz, Donald L.; Anderson, Douglas R.

    2010-01-01

    OBJECTIVE To evaluate a new automated analysis of optic disc images obtained by spectral domain optical coherence tomography (SD-OCT). Areas of the optic disc, cup, and neural rim in SD-OCT images were compared with these areas from stereoscopic photographs, to represent the current traditional optic nerve evaluation. The repeatability of measurements by each method was determined and compared. DESIGN Evaluation of diagnostic technology. PARTICIPANTS 119 healthy eyes, 23 eyes with glaucoma, and 7 suspect eyes METHODS Optic disc and cup margins were traced from stereoscopic photographs by three individuals independently. Optic disc margins and rim widths were determined automatically in SD-OCT. A subset of photographs was examined and traced a second time, and duplicate SD-OCT images were also analyzed. MAIN OUTCOME MEASUREMENTS Agreement among photograph readers, between duplicate readings, and between SD-OCT and photographs were quantified by the intraclass correlation coefficient (ICC), by the root mean square (RMS), and the standard deviation (SD) of the differences. RESULTS Optic disc areas tended to be slightly larger when judged in photographs than by SD-OCT, while cup areas were similar. Cup and optic disc areas showed good correlation (0.8) between average photographic reading and SD-OCT, but only fair correlation of rim areas (0.4). The SD-OCT was highly reproducible (ICC of 0.96 to 0.99). Each reader was also consistent with himself on duplicate readings of 21 photographs (ICC 0.80 to 0.88 for rim area, 0.95 to 0.98 for all other measurements), but reproducibility was not as good as SD-OCT. Measurements derived from SD-OCT did not differ from photographic readings more than the readings of photographs by different readers differed from each other. CONCLUSIONS Designation of the cup and optic disc boundaries by an automated analysis of SD-OCT was within the range of variable designations by different readers from color stereoscopic photographs, but use of different landmarks typically made the designation of the optic disc size somewhat smaller in the automated analysis. There was better repeatability among measurements from SD-OCT than from among readers of photographs. The repeatability of automated measurement of SD-OCT images is promising for use both in diagnosis and in monitoring of progression. PMID:21397334

  11. Development of LEDs-based microplate reader for bioanalytical assay measurements

    NASA Astrophysics Data System (ADS)

    Alaruri, Sami D.; Katzlinger, Michael; Schinwald, Bernhard; Kronberger, Georg; Atzler, Joseph

    2013-10-01

    The optical design for an LEDs-based microplate reader that can perform fluorescence intensity (top and bottom), absorbance, luminescence and time-resolved fluorescence measurements is described. The microplate reader is the first microplate reader in the marketplace that incorporates LEDs as excitation light sources. Absorbance measurements over the 0-3.5 optical density range for caffeine solution are presented. Additionally, fluorescence intensity readings collected at 535 and 625 nm from a green and a red RediPlateTM are reported. Furthermore, fluorescence decay lifetime measurements obtained for Eu (europium) and Sm (samarium) standard solutions using 370 nm excitation are presented. The microplate reader detection limits for the fluorescence intensity top, fluorescence intensity bottom, fluorescence polarization and time-resolved fluorescence modes are 1.5 fmol 100 µL-1 fluorescein (384-well plate), 25 fmol 100 µL-1 fluorescein (384-well plate), 5 mP at 10 nM fluorescein (black 384-well plate) and 30 amol 100 µL-1 europium solution (white 384-well plate), respectively.

  12. Compact touchless fingerprint reader based on digital variable-focus liquid lens

    NASA Astrophysics Data System (ADS)

    Tsai, C. W.; Wang, P. J.; Yeh, J. A.

    2014-09-01

    Identity certification in the cyberworld has always been troublesome if critical information and financial transaction must be processed. Biometric identification is the most effective measure to circumvent the identity issues in mobile devices. Due to bulky and pricy optical design, conventional optical fingerprint readers have been discarded for mobile applications. In this paper, a digital variable-focus liquid lens was adopted for capture of a floating finger via fast focusplane scanning. Only putting a finger in front of a camera could fulfill the fingerprint ID process. This prototyped fingerprint reader scans multiple focal planes from 30 mm to 15 mm in 0.2 second. Through multiple images at various focuses, one of the images is chosen for extraction of fingerprint minutiae used for identity certification. In the optical design, a digital liquid lens atop a webcam with a fixed-focus lens module is to fast-scan a floating finger at preset focus planes. The distance, rolling angle and pitching angle of the finger are stored for crucial parameters during the match process of fingerprint minutiae. This innovative compact touchless fingerprint reader could be packed into a minute size of 9.8*9.8*5 (mm) after the optical design and multiple focus-plane scan function are optimized.

  13. Identifying and preserving high-water mark data

    USGS Publications Warehouse

    Koenig, Todd A.; Bruce, Jennifer L.; O'Connor, Jim; McGee, Benton D.; Holmes, Robert R.; Hollins, Ryan; Forbes, Brandon T.; Kohn, Michael S.; Schellekens, Mathew; Martin, Zachary W.; Peppler, Marie C.

    2016-03-08

    High-water marks provide valuable data for understanding recent and historical flood events. The proper collection and recording of high-water mark data from perishable and preserved evidence informs flood assessments, research, and water resource management. Given the high cost of flooding in developed areas, experienced hydrographers, using the best available techniques, can contribute high-quality data toward efforts such as public education of flood risk, flood inundation mapping, flood frequency computations, indirect streamflow measurement, and hazard assessments.This manual presents guidance for skilled high-water mark identification, including marks left behind in natural and man-made environments by tranquil and rapid flowing water. This manual also presents pitfalls and challenges associated with various types of flood evidence that help hydrographers identify the best high-water marks and assess the uncertainty associated with a given mark. Proficient high-water mark data collection contributes to better understanding of the flooding process and reduces risk through greater ability to estimate flood probability.The U.S. Geological Survey, operating the Nation’s premier water data collection network, encourages readers of this manual to familiarize themselves with the art and science of high-water mark collection. The U.S. Geological survey maintains a national database at http://water.usgs.gov/floods/FEV/ that includes high-water mark information for many flood events, and local U.S. Geological Survey Water Science Centers can provide information to interested readers about participation in data collection and flood documentation efforts as volunteers or observers.

  14. CCD imaging technology and the war on crime

    NASA Astrophysics Data System (ADS)

    McNeill, Glenn E.

    1992-08-01

    Linear array based CCD technology has been successfully used in the development of an Automatic Currency Reader/Comparator (ACR/C) system. The ACR/C system is designed to provide a method for tracking US currency in the organized crime and drug trafficking environments where large amounts of cash are involved in illegal transactions and money laundering activities. United States currency notes can be uniquely identified by the combination of the denomination serial number and series year. The ACR/C system processes notes at five notes per second using a custom transport a stationary linear array and optical character recognition (OCR) techniques to make such identifications. In this way large sums of money can be " marked" (using the system to read and store their identifiers) and then circulated within various crime networks. The system can later be used to read and compare confiscated notes to the known sets of identifiers from the " marked" set to document a trail of criminal activities. With the ACR/C law enforcement agencies can efficiently identify currency without actually marking it. This provides an undetectable means for making each note individually traceable and facilitates record keeping for providing evidence in a court of law. In addition when multiple systems are used in conjunction with a central data base the system can be used to track currency geographically. 1.

  15. The interplay of attention economics and computer-aided detection marks in screening mammography

    NASA Astrophysics Data System (ADS)

    Schwartz, Tayler M.; Sridharan, Radhika; Wei, Wei; Lukyanchenko, Olga; Geiser, William; Whitman, Gary J.; Haygood, Tamara Miner

    2016-03-01

    Introduction: According to attention economists, overabundant information leads to decreased attention for individual pieces of information. Computer-aided detection (CAD) alerts radiologists to findings potentially associated with breast cancer but is notorious for creating an abundance of false-positive marks. We suspected that increased CAD marks do not lengthen mammogram interpretation time, as radiologists will selectively disregard these marks when present in larger numbers. We explore the relevance of attention economics in mammography by examining how the number of CAD marks affects interpretation time. Methods: We performed a retrospective review of bilateral digital screening mammograms obtained between January 1, 2011 and February 28, 2014, using only weekend interpretations to decrease distractions and the likelihood of trainee participation. We stratified data according to reader and used ANOVA to assess the relationship between number of CAD marks and interpretation time. Results: Ten radiologists, with median experience after residency of 12.5 years (range 6 to 24,) interpreted 1849 mammograms. When accounting for number of images, Breast Imaging Reporting and Data System category, and breast density, increasing numbers of CAD marks was correlated with longer interpretation time only for the three radiologists with the fewest years of experience (median 7 years.) Conclusion: For the 7 most experienced readers, increasing CAD marks did not lengthen interpretation time. We surmise that as CAD marks increase, the attention given to individual marks decreases. Experienced radiologists may rapidly dismiss larger numbers of CAD marks as false-positive, having learned that devoting extra attention to such marks does not improve clinical detection.

  16. Editorial, Forum and Book Review

    NASA Astrophysics Data System (ADS)

    Caulfield, H. J.

    1981-04-01

    In keeping with my desire to make editorial decisions openly and to seek reader response to those decisions, I want to announce a policy on the citation of military classified information in Optical Engineering. The problem, is a vexing one. If the purpose of a paper is to convey the maximum amount of information about a topic, should it trouble your editor that otherwise-useful references are inaccessible to some of the readers? Should he deliber-ately suppress the information that related material is available because some of the readers cannot use that material? Should the editor ban references to an obscure Dutch journal (for example) because some of the readers cannot use that material? Yet, there is something distasteful about citing classified material. Does it make Optical Engineering American and not international? Could it become a Department of Defense outlet for unclassified information? Would it be elitist?

  17. Transformation optics with windows

    NASA Astrophysics Data System (ADS)

    Oxburgh, Stephen; White, Chris D.; Antoniou, Georgios; Orife, Ejovbokoghene; Courtial, Johannes

    2014-09-01

    Identity certification in the cyberworld has always been troublesome if critical information and financial transaction must be processed. Biometric identification is the most effective measure to circumvent the identity issues in mobile devices. Due to bulky and pricy optical design, conventional optical fingerprint readers have been discarded for mobile applications. In this paper, a digital variable-focus liquid lens was adopted for capture of a floating finger via fast focusplane scanning. Only putting a finger in front of a camera could fulfill the fingerprint ID process. This prototyped fingerprint reader scans multiple focal planes from 30 mm to 15 mm in 0.2 second. Through multiple images at various focuses, one of the images is chosen for extraction of fingerprint minutiae used for identity certification. In the optical design, a digital liquid lens atop a webcam with a fixed-focus lens module is to fast-scan a floating finger at preset focus planes. The distance, rolling angle and pitching angle of the finger are stored for crucial parameters during the match process of fingerprint minutiae. This innovative compact touchless fingerprint reader could be packed into a minute size of 9.8*9.8*5 (mm) after the optical design and multiple focus-plane scan function are optimized.

  18. Analytical validation of an ultra low-cost mobile phone microplate reader for infectious disease testing.

    PubMed

    Wang, Li-Ju; Naudé, Nicole; Demissie, Misganaw; Crivaro, Anne; Kamoun, Malek; Wang, Ping; Li, Lei

    2018-07-01

    Most mobile health (mHealth) diagnostic devices for laboratory tests only analyze one sample at a time, which is not suitable for large volume serology testing, especially in low-resource settings with shortage of health professionals. In this study, we developed an ultra-low-cost clinically-accurate mobile phone microplate reader (mReader), and clinically validated this optical device for 12 infectious disease tests. The mReader optically reads 96 samples on a microplate at one time. 771 de-identified patient samples were tested for 12 serology assays for bacterial/viral infections. The mReader and the clinical instrument blindly read and analyzed all tests in parallel. The analytical accuracy and the diagnostic performance of the mReader were evaluated across the clinical reportable categories by comparison with clinical laboratorial testing results. The mReader exhibited 97.59-99.90% analytical accuracy and <5% coefficient of variation (CV). The positive percent agreement (PPA) in all 12 tests achieved 100%, negative percent agreement (NPA) was higher than 83% except for one test (42.86%), and overall percent agreement (OPA) ranged 89.33-100%. We envision the mReader can benefit underserved areas/populations and low-resource settings in rural clinics/hospitals at a low cost (~$50 USD) with clinical-level analytical quality. It has the potential to improve health access, speed up healthcare delivery, and reduce health disparities and education disparities by providing access to a low-cost spectrophotometer. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. How To Write with Style. Power of the Printed Word.

    ERIC Educational Resources Information Center

    Vonnegut, Kurt

    Elements of a writer's style reveal to readers what sort of a person it is with whom they are spending time. These revelations are important because they are a mark of respect for readers. To develop style, follow these guidelines. Find a subject to care about and which others should care about. It is this caring which will be the most seductive…

  20. Efficacy of identifying stocked crappies in a Tennessee reservoir through oxytetracycline marking

    USGS Publications Warehouse

    Isermann, D.A.; Bettoli, P.W.; Sammons, S.M.

    1999-01-01

    Oxytetracycline (OTC) immersion was used to identify black-nosed crappies, a morphological variation of black crappie Pomoxis nigromaculatus, stocked into Normandy Reservoir, Tennessee, during fall 1997. The technique effectively marked 97% of the treated fish. Analysis of one otolith per fish by one reader successfully identified 98% of marked and unmarked fish in a blind test. Marks were formed before annulus formation and were not obscured by annulus-related autofluorescence, suggesting that OTC can be effectively used late in the year (October and November) in Tennessee.

  1. The Adoption of Mark-Up Tools in an Interactive e-Textbook Reader

    ERIC Educational Resources Information Center

    Van Horne, Sam; Russell, Jae-eun; Schuh, Kathy L.

    2016-01-01

    Researchers have more often examined whether students prefer using an e-textbook over a paper textbook or whether e-textbooks provide a better resource for learning than paper textbooks, but students' adoption of mark-up tools has remained relatively unexamined. Drawing on the concept of Innovation Diffusion Theory, we used educational data mining…

  2. Shaping epigenetic memory via genomic bookmarking.

    PubMed

    Michieletto, Davide; Chiang, Michael; Colì, Davide; Papantonis, Argyris; Orlandini, Enzo; Cook, Peter R; Marenduzzo, Davide

    2018-01-09

    Reconciling the stability of epigenetic patterns with the rapid turnover of histone modifications and their adaptability to external stimuli is an outstanding challenge. Here, we propose a new biophysical mechanism that can establish and maintain robust yet plastic epigenetic domains via genomic bookmarking (GBM). We model chromatin as a recolourable polymer whose segments bear non-permanent histone marks (or colours) which can be modified by 'writer' proteins. The three-dimensional chromatin organisation is mediated by protein bridges, or 'readers', such as Polycomb Repressive Complexes and Transcription Factors. The coupling between readers and writers drives spreading of biochemical marks and sustains the memory of local chromatin states across replication and mitosis. In contrast, GBM-targeted perturbations destabilise the epigenetic patterns. Strikingly, we demonstrate that GBM alone can explain the full distribution of Polycomb marks in a whole Drosophila chromosome. We finally suggest that our model provides a starting point for an understanding of the biophysics of cellular differentiation and reprogramming. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  3. Roadway Marking Optics for Autonomous Vehicle Guidance and Other Machine Vision Applications

    NASA Astrophysics Data System (ADS)

    Konopka, Anthony T.

    This work determines optimal planar geometric light source and optical imager configurations and electromagnetic wavelengths for maximizing the reflected signal intensity when using machine vision technology to image roadway markings with embedded spherical glass beads. It is found through a first set of experiments that roadway marking samples exhibiting little or no bead rolling effects are uniformly reflective with respect to the azimuthal angle of observation when measured for retroreflectivity within industry standard 30-meter geometry. A second set of experiments indicate that white roadway markings exhibit higher reflectivity throughout the visible spectrum than yellow roadway markings. A roadway marking optical model capable of being used to determine optimal geometric light source and optical imager configurations for maximizing the reflected signal intensities of roadway marking targets is constructed and simulated using optical engineering software. It is found through a third set of experiments that high signal intensities can be measured when the polar angles of the light source and optical imager along a plane normal to a roadway marking are equal, with the maximum signal intensity being measured when the polar angles of both the light source and optical imager are 90°.

  4. Reading between the lines: Societal norms in Sierra Leonean readers

    NASA Astrophysics Data System (ADS)

    Brams, Patricia

    1980-12-01

    A content analysis of primary school readers of Sierra Leone revealed that the particular modern and traditional normative aspirations expressed in the National Development Plan for 1974/75-1978/79 were also generally reflected in the children's readers. Compared to the 1964 readers, the first indigenous readers developed circa 1977 contained markedly greater emphasis on traditional norms, though modernity norms continued to dominate, and substantially less emphasis on Efficacy (a central aspect of modernity) and on Non-parochial Affiliation. This closely corresponded with the intent of the National Plan to continue on a modernizing course employing the traditional norms of Manual Labor and Social Cohesion in a grassroots effort to develop the agricultural sector, with nationalism in a less important role. Apart from lesser emphasis on Efficacy and underemphasis on the Value of Education which were discordant with national goals, the 1977 readers seem to provide children and teachers with a fairly accurate image of the national ethos. This may help to account for the generally positive relationship that has been found between schooling and economic development.

  5. Computer-aided detection of pulmonary embolism at CT pulmonary angiography: can it improve performance of inexperienced readers?

    PubMed

    Blackmon, Kevin N; Florin, Charles; Bogoni, Luca; McCain, Joshua W; Koonce, James D; Lee, Heon; Bastarrika, Gorka; Thilo, Christian; Costello, Philip; Salganicoff, Marcos; Joseph Schoepf, U

    2011-06-01

    To evaluate the effect of a computer-aided detection (CAD) algorithm on the performance of novice readers for detection of pulmonary embolism (PE) at CT pulmonary angiography (CTPA). We included CTPA examinations of 79 patients (50 female, 52 ± 18 years). Studies were evaluated by two independent inexperienced readers who marked all vessels containing PE. After 3 months all studies were reevaluated by the same two readers, this time aided by CAD prototype. A consensus read by three expert radiologists served as the reference standard. Statistical analysis used χ(2) and McNemar testing. Expert consensus revealed 119 PEs in 32 studies. For PE detection, the sensitivity of CAD alone was 78%. Inexperienced readers' initial interpretations had an average per-PE sensitivity of 50%, which improved to 71% (p < 0.001) with CAD as a second reader. False positives increased from 0.18 to 0.25 per study (p = 0.03). Per-study, the readers initially detected 27/32 positive studies (84%); with CAD this number increased to 29.5 studies (92%; p = 0.125). Our results suggest that CAD significantly improves the sensitivity of PE detection for inexperienced readers with a small but appreciable increase in the rate of false positives.

  6. Reader interactome of epigenetic histone marks in birds.

    PubMed

    Bluhm, Alina; Casas-Vila, Nuria; Scheibe, Marion; Butter, Falk

    2016-02-01

    Lysine methylation is part of the posttranscriptional histone code employed to recruit modification specific readers to chromatin. Unbiased, quantitative mass spectrometry approaches combined with peptide pull-downs have been used to study histone methylation-dependent binders in mammalian cells. Here, we extend the study to birds by investigating the interaction partners for H3K4me3, H3K9me3, H3K27me3 and H3K36me3 in chicken (Gallus gallus) and zebra finch (Taeniopygia guttata) using label-free quantitative proteomics. In general, we find very strong overlap in interaction partners for the trimethyl marks in birds compared to mammals, underscoring the known conserved function of these modifications. In agreement with their epigenetic role, we find binding of PHF2 and members of the TFIID, SAGA, SET1 and NURF complex to the activation mark H3K4me3. Our data furthermore supports the existence of a LID complex in vertebrates recruited to the H3K4me3 mark. The repressive marks are bound by the HP1 proteins and the EED subunit of the PRC2 complex as well as by WIZ. Like reported in the previous mammalian screens, we found ZNF462, ZNF828 and POGZ enriched at H3K9me3. However, we noted some unexpected differences. N-PAC (also known as GLYR1), an H3K36me3 interactor in mammals, is reproducible not enriched at this modification in our screen in birds. This initial finding suggests that despite strong conservation of the histone tail sequence, a few species-specific differences in epigenetic readers may have evolved between birds and mammals. All MS data have been deposited in the ProteomeXchange with identifier PXD002282 (http://proteomecentral.proteomexchange.org/dataset/PXD002282). © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Automatic neutron dosimetry system based on fluorescent nuclear track detector technology.

    PubMed

    Akselrod, M S; Fomenko, V V; Bartz, J A; Haslett, T L

    2014-10-01

    For the first time, the authors are describing an automatic fluorescent nuclear track detector (FNTD) reader for neutron dosimetry. FNTD is a luminescent integrating type of detector made of aluminium oxide crystals that does not require electronics or batteries during irradiation. Non-destructive optical readout of the detector is performed using a confocal laser scanning fluorescence imaging with near-diffraction limited resolution. The fully automatic table-top reader allows one to load up to 216 detectors on a tray, read their engraved IDs using a CCD camera and optical character recognition, scan and process simultaneously two types of images in fluorescent and reflected laser light contrast to eliminate false-positive tracks related to surface and volume crystal imperfections. The FNTD dosimetry system allows one to measure neutron doses from 0.1 mSv to 20 Sv and covers neutron energies from thermal to 20 MeV. The reader is characterised by a robust, compact optical design, fast data processing electronics and user-friendly software. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Infrared optical manufacturing trends

    NASA Astrophysics Data System (ADS)

    Myers, Jennifer L.; Alexay, Christopher C.

    2005-10-01

    This paper attempts to inform and educate readers to some of the more recent changes in infrared material pricing and availability along with the impact of optical manufacturing trends and the means by which optical designers, manufacturers and product end-users are using to avoid or eliminate the pitfalls these changes may create.

  9. High-throughput measurements of the optical redox ratio using a commercial microplate reader.

    PubMed

    Cannon, Taylor M; Shah, Amy T; Walsh, Alex J; Skala, Melissa C

    2015-01-01

    There is a need for accurate, high-throughput, functional measures to gauge the efficacy of potential drugs in living cells. As an early marker of drug response in cells, cellular metabolism provides an attractive platform for high-throughput drug testing. Optical techniques can noninvasively monitor NADH and FAD, two autofluorescent metabolic coenzymes. The autofluorescent redox ratio, defined as the autofluorescence intensity of NADH divided by that of FAD, quantifies relative rates of cellular glycolysis and oxidative phosphorylation. However, current microscopy methods for redox ratio quantification are time-intensive and low-throughput, limiting their practicality in drug screening. Alternatively, high-throughput commercial microplate readers quickly measure fluorescence intensities for hundreds of wells. This study found that a commercial microplate reader can differentiate the receptor status of breast cancer cell lines (p < 0.05) based on redox ratio measurements without extrinsic contrast agents. Furthermore, microplate reader redox ratio measurements resolve response (p < 0.05) and lack of response (p > 0.05) in cell lines that are responsive and nonresponsive, respectively, to the breast cancer drug trastuzumab. These studies indicate that the microplate readers can be used to measure the redox ratio in a high-throughput manner and are sensitive enough to detect differences in cellular metabolism that are consistent with microscopy results.

  10. Evaluating Mobile Device Ownership and Usage in the U.S. Army: Implications for Army Training

    DTIC Science & Technology

    2014-07-01

    any of the following mobile devices? MARK ALL THAT APPLY? iPhone iPad (or other tablet PC) iPhone Touch Android smartphone Blackberry E-Reader (e.g...THAT APPLY? iPhone iPad (or other tablet PC) iPhone Touch Android smartphone Blackberry E-Reader (e.g., Kindle, Nook) None of the above 5...age groups owned more iPhones than Android or Blackberrys . These trends changed as age increased. Upper- middle-aged Soldiers owned a mix of

  11. Variable Distance Angular Symbology Reader

    NASA Technical Reports Server (NTRS)

    Schramm, Harry F., Jr. (Inventor); Corder, Eric L. (Inventor)

    2006-01-01

    A variable distance angular symbology, reader utilizes at least one light source to direct light through a beam splitter and onto a target. A target may be angled relative to the impinging light beam up to and maybe even greater than 45deg. A reflected beam from the target passes through the beam splitter and is preferably directed 90deg relative to the light source through a telecentric lens to a scanner which records an image of the target such as a direct part marking code.

  12. Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography.

    PubMed

    Tay, Elton Lik Tong; Yong, Vernon Khet Yau; Lim, Boon Ang; Sia, Stelson; Wong, Elizabeth Poh Ying; Yip, Leonard Wei Leon

    2015-01-01

    To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography (AS-OCT), as well as gonioscopy and spectral domain OCT (SD-OCT). A secondary objective was to quantify inter-observer agreements of AS-OCT and SD-OCT assessments. Seventeen consecutive subjects (33 eyes) were recruited from the study hospital's Glaucoma clinic. Gonioscopy was performed by a glaucomatologist masked to OCT results. OCT images were read independently by 2 other glaucomatologists masked to gonioscopy findings as well as each other's analyses of OCT images. Totally 84.8% and 45.5% of scleral spurs were visualized in AS-OCT and SD-OCT images respectively (P<0.01). The agreement for angle closure between AS-OCT and gonioscopy was fair at k=0.31 (95% confidence interval, CI: 0.03-0.59) and k=0.35 (95% CI: 0.07-0.63) for reader 1 and 2 respectively. The agreement for angle closure between SD-OCT and gonioscopy was fair at k=0.21 (95% CI: 0.07-0.49) and slight at k=0.17 (95% CI: 0.08-0.42) for reader 1 and 2 respectively. The inter-reader agreement for angle closure in AS-OCT images was moderate at 0.51 (95% CI: 0.13-0.88). The inter-reader agreement for angle closure in SD-OCT images was slight at 0.18 (95% CI: 0.08-0.45). Significant proportion of scleral spurs were not visualised with SD-OCT imaging resulting in weaker inter-reader agreements. Identifying other angle landmarks in SD-OCT images will allow more consistent angle closure assessments. Gonioscopy and OCT imaging do not always agree in angle closure assessments but have their own advantages, and should be used together and not exclusively.

  13. ATAD2 is an epigenetic reader of newly synthesized histone marks during DNA replication.

    PubMed

    Koo, Seong Joo; Fernández-Montalván, Amaury E; Badock, Volker; Ott, Christopher J; Holton, Simon J; von Ahsen, Oliver; Toedling, Joern; Vittori, Sarah; Bradner, James E; Gorjánácz, Mátyás

    2016-10-25

    ATAD2 (ATPase family AAA domain-containing protein 2) is a chromatin regulator harboring an AAA+ ATPase domain and a bromodomain, previously proposed to function as an oncogenic transcription co-factor. Here we suggest that ATAD2 is also required for DNA replication. ATAD2 is co-expressed with genes involved in DNA replication in various cancer types and predominantly expressed in S phase cells where it localized on nascent chromatin (replication sites). Our extensive biochemical and cellular analyses revealed that ATAD2 is recruited to replication sites through a direct interaction with di-acetylated histone H4 at K5 and K12, indicative of newly synthesized histones during replication-coupled chromatin reassembly. Similar to ATAD2-depletion, ectopic expression of ATAD2 mutants that are deficient in binding to these di-acetylation marks resulted in reduced DNA replication and impaired loading of PCNA onto chromatin, suggesting relevance of ATAD2 in DNA replication. Taken together, our data show a novel function of ATAD2 in cancer and for the first time identify a reader of newly synthesized histone di-acetylation-marks during replication.

  14. Histone demethylase KDM5A is regulated by its reader domain through a positive-feedback mechanism

    NASA Astrophysics Data System (ADS)

    Torres, Idelisse Ortiz; Kuchenbecker, Kristopher M.; Nnadi, Chimno I.; Fletterick, Robert J.; Kelly, Mark J. S.; Fujimori, Danica Galonić

    2015-02-01

    The retinoblastoma binding protein KDM5A removes methyl marks from lysine 4 of histone H3 (H3K4). Misregulation of KDM5A contributes to the pathogenesis of lung and gastric cancers. In addition to its catalytic jumonji C domain, KDM5A contains three PHD reader domains, commonly recognized as chromatin recruitment modules. It is unknown whether any of these domains in KDM5A have functions beyond recruitment and whether they regulate the catalytic activity of the demethylase. Here using biochemical and nuclear magnetic resonance (NMR)-based structural studies, we show that the PHD1 preferentially recognizes unmethylated H3K4 histone tail, product of KDM5A-mediated demethylation of tri-methylated H3K4 (H3K4me3). Binding of unmodified H3 peptide to the PHD1 stimulates catalytic domain-mediated removal of methyl marks from H3K4me3 peptide and nucleosome substrates. This positive-feedback mechanism—enabled by the functional coupling between a reader and a catalytic domain in KDM5A—suggests a model for the spread of demethylation on chromatin.

  15. Performance of an optical identification and interrogation system

    NASA Astrophysics Data System (ADS)

    Venugopalan, A.; Ghosh, A. K.; Verma, P.; Cheng, S.

    2008-04-01

    A free space optics based identification and interrogation system has been designed. The applications of the proposed system lie primarily in areas which require a secure means of mutual identification and information exchange between optical readers and tags. Conventional RFIDs raise issues regarding security threats, electromagnetic interference and health safety. The security of RF-ID chips is low due to the wide spatial spread of radio waves. Malicious nodes can read data being transmitted on the network, if they are in the receiving range. The proposed system provides an alternative which utilizes the narrow paraxial beams of lasers and an RSA-based authentication scheme. These provide enhanced security to communication between a tag and the base station or reader. The optical reader can also perform remote identification and the tag can be read from a far off distance, given line of sight. The free space optical identification and interrogation system can be used for inventory management, security systems at airports, port security, communication with high security systems, etc. to name a few. The proposed system was implemented with low-cost, off-the-shelf components and its performance in terms of throughput and bit error rate has been measured and analyzed. The range of operation with a bit-error-rate lower than 10-9 was measured to be about 4.5 m. The security of the system is based on the strengths of the RSA encryption scheme implemented using more than 1024 bits.

  16. Developmental Trajectories for Children With Dyslexia and Low IQ Poor Readers

    PubMed Central

    2016-01-01

    Reading difficulties are found in children with both high and low IQ and it is now clear that both groups exhibit difficulties in phonological processing. Here, we apply the developmental trajectories approach, a new methodology developed for studying language and cognitive impairments in developmental disorders, to both poor reader groups. The trajectory methodology enables identification of atypical versus delayed development in datasets gathered using group matching designs. Regarding the cognitive predictors of reading, which here are phonological awareness, phonological short-term memory (PSTM) and rapid automatized naming (RAN), the method showed that trajectories for the two groups diverged markedly. Children with dyslexia showed atypical development in phonological awareness, while low IQ poor readers showed developmental delay. Low IQ poor readers showed atypical PSTM and RAN development, but children with dyslexia showed developmental delay. These divergent trajectories may have important ramifications for supporting each type of poor reader, although all poor readers showed weakness in all areas. Regarding auditory processing, the developmental trajectories were very similar for the two poor reader groups. However, children with dyslexia demonstrated developmental delay for auditory discrimination of Duration, while the low IQ children showed atypical development on this measure. The data show that, regardless of IQ, poor readers have developmental trajectories that differ from typically developing children. The trajectories approach enables differences in trajectory classification to be identified across poor reader group, as well as specifying the individual nature of these trajectories. PMID:27110928

  17. Microfluidic point-of-care diagnostics for resource-poor environments

    NASA Astrophysics Data System (ADS)

    Laksanasopin, Tassaneewan; Chin, Curtis D.; Moore, Hannah; Wang, Jennifer; Cheung, Yuk Kee; Sia, Samuel K.

    2009-05-01

    Point-of-care (POC) diagnostics have tremendous potential to improve human health in remote and resource-poor settings. However, the design criteria for diagnostic tests appropriate in settings with limited infrastructure are unique and challenging. Here we present a custom optical reader which quantifies silver absorbance from heterogeneous immunoassays. The reader is simple and low-cost and suited for POC diagnostics.

  18. Reflections on 35 years with Applied Optics: outgoing editorial.

    PubMed

    Mait, Joseph N

    2014-10-20

    Applied Optics' Editor-in-Chief, Joseph N. Mait reflects on his experience as a reader, author, reviewer and eventual editor of the journal. Dr. Mait also introduces the incoming Editor-in-Chief, Ronald G. Driggers and acknowledges outgoing Division Editor, T.-C. Poon.

  19. A comparison of conventional capture versus PIT reader techniques for estimating survival and capture probabilities of big brown bats (Eptesicus fuscus)

    USGS Publications Warehouse

    Ellison, L.E.; O'Shea, T.J.; Neubaum, D.J.; Neubaum, M.A.; Pearce, R.D.; Bowen, R.A.

    2007-01-01

    We compared conventional capture (primarily mist nets and harp traps) and passive integrated transponder (PIT) tagging techniques for estimating capture and survival probabilities of big brown bats (Eptesicus fuscus) roosting in buildings in Fort Collins, Colorado. A total of 987 female adult and juvenile bats were captured and marked by subdermal injection of PIT tags during the summers of 2001-2005 at five maternity colonies in buildings. Openings to roosts were equipped with PIT hoop-style readers, and exit and entry of bats were passively monitored on a daily basis throughout the summers of 2002-2005. PIT readers 'recaptured' adult and juvenile females more often than conventional capture events at each roost. Estimates of annual capture probabilities for all five colonies were on average twice as high when estimated from PIT reader data (P?? = 0.93-1.00) than when derived from conventional techniques (P?? = 0.26-0.66), and as a consequence annual survival estimates were more precisely estimated when using PIT reader encounters. Short-term, daily capture estimates were also higher using PIT readers than conventional captures. We discuss the advantages and limitations of using PIT tags and passive encounters with hoop readers vs. conventional capture techniques for estimating these vital parameters in big brown bats. ?? Museum and Institute of Zoology PAS.

  20. Investigating the causes of wrap-up effects: evidence from eye movements and E-Z Reader.

    PubMed

    Warren, Tessa; White, Sarah J; Reichle, Erik D

    2009-04-01

    Wrap-up effects in reading have traditionally been thought to reflect increased processing associated with intra- and inter-clause integration (Just, M. A. & Carpenter, P. A. (1980). A theory of reading: From eye fixations to comprehension. Psychological Review,87(4), 329-354; Rayner, K., Kambe, G., & Duffy, S. A. (2000). The effect of clause wrap-up on eye movements during reading. The Quarterly Journal of Experimental Psychology,53A(4), 1061-1080; cf. Hirotani, M., Frazier, L., & Rayner, K. (2006). Punctuation and intonation effects on clause and sentence wrap-up: Evidence from eye movements. Journal of Memory and Language,54, 425-443). We report an eye-tracking experiment with a strong manipulation of integrative complexity at a critical word that was either sentence-final, ended a comma-marked clause, or was not comma-marked. Although both complexity and punctuation had reliable effects, they did not interact in any eye-movement measure. These results as well as simulations using the E-Z Reader model of eye-movement control (Reichle, E. D., Warren, T., & McConnell, K. (2009). Using E-Z Reader to model the effects of higher-level language processing on eye movements during reading. Psychonomic Bulletin & Review,16(1), 1-20) suggest that traditional accounts of clause wrap-up are incomplete.

  1. Pavement marking visibility requirements during wet night conditions.

    DOT National Transportation Integrated Search

    2006-01-01

    This study investigated the performance of pavement markings in wet night conditions. Typically, performance will decrease in wet conditions. The degradation is a result of flooding of the marking optics and a change in the optical media, thereby red...

  2. Deep infiltrating endometriosis: Should rectal and vaginal opacification be systematically used in MR imaging?

    PubMed

    Uyttenhove, F; Langlois, C; Collinet, P; Rubod, C; Verpillat, P; Bigot, J; Kerdraon, O; Faye, N

    2016-06-01

    To evaluate the interest of rectal and vaginal filling in vaginal and recto-sigmoid endometriosis with MR imaging. To compare the results between a senior and a junior radiologist review. Sixty-seven patients with clinically suspected deep infiltrating endometriosis were included in our MRI protocol consisting of repeated T2-weigthed sequences (axial and sagittal) before and after rectal and vaginal marking with ultrasonography gel. Vaginal and recto-sigmoid endometriosis lesions were analyzed before and after opacification. The inter-reader agreement between senior and junior scores was studied. Concerning vaginal and muscularis and beyond colonic involvement, no significant difference (P=0.32) was observed and the inter-reader agreement was excellent (K=0.96 and 0.97 respectively). Concerning serosa colonic lesions, a significant difference was observed (P=0.01) and the inter-reader agreement was poor (K=0). Rectal and vaginal filling in endometriosis staging with MRI is not necessary no matter the reader experiment. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. A Combinatorial Platform for the Optimization of Peptidomimetic Methyl-Lysine Reader Antagonists

    NASA Astrophysics Data System (ADS)

    Barnash, Kimberly D.

    Post-translational modification of histone N-terminal tails mediates chromatin compaction and, consequently, DNA replication, transcription, and repair. While numerous post-translational modifications decorate histone tails, lysine methylation is an abundant mark important for both gene activation and repression. Methyl-lysine (Kme) readers function through binding mono-, di-, or trimethyl-lysine. Chemical intervention of Kme readers faces numerous challenges due to the broad surface-groove interactions between readers and their cognate histone peptides; yet, the increasing interest in understanding chromatin-modifying complexes suggests tractable lead compounds for Kme readers are critical for elucidating the mechanisms of chromatin dysregulation in disease states and validating the druggability of these domains and complexes. The successful discovery of a peptide-derived chemical probe, UNC3866, for the Polycomb repressive complex 1 (PRC1) chromodomain Kme readers has proven the potential for selective peptidomimetic inhibition of reader function. Unfortunately, the systematic modification of peptides-to-peptidomimetics is a costly and inefficient strategy for target-class hit discovery against Kme readers. Through the exploration of biased chemical space via combinatorial on-bead libraries, we have developed two concurrent methodologies for Kme reader chemical probe discovery. We employ biased peptide combinatorial libraries as a hit discovery strategy with subsequent optimization via iterative targeted libraries. Peptide-to-peptidomimetic optimization through targeted library design was applied based on structure-guided library design around the interaction of the endogenous peptide ligand with three target Kme readers. Efforts targeting the WD40 reader EED led to the discovery of the 3-mer peptidomimetic ligand UNC5115 while combinatorial repurposing of UNC3866 for off-target chromodomains resulted in the discovery of UNC4991, a CDYL/2-selective ligand, and UNC4848, a MPP8 and CDYL/2 ligand. Ultimately, our efforts demonstrate the generalizability of a peptidomimetic combinatorial platform for the optimization of Kme reader ligands in a target class manner.

  4. 1990 censuses to increase use of automation.

    PubMed

    Ward, S E

    1988-12-01

    This article summarizes information from selected reports presented at the 12th Population Census Conference. Ward reports that plans for the 1990 census in many countries of Asia and the Pacific call for increased use of automation, with applications ranging from the use of computer-generated maps of enumeration areas and optical mark readers for data processing to desktop publishing and electronic mail for disseminating the results. Recent advances in automation offer opportunities for improved accuracy and speed of census operations while reducing the need for clerical personnel. Most of the technologies discussed at the 12th Population Census are designed to make the planning, editing, processing, analysis, and publication of census data more reliable and efficient. However, technology alone cannot overcome high rates of illiteracy that preclude having respondents complete the census forms themselves. But it enables even China, India, Indonesia and Pakistan - the countries with huge population and limited financial resources - to make significant improvements in their forthcoming censuses.

  5. Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography

    PubMed Central

    Tay, Elton Lik Tong; Yong, Vernon Khet Yau; Lim, Boon Ang; Sia, Stelson; Wong, Elizabeth Poh Ying; Yip, Leonard Wei Leon

    2015-01-01

    AIM To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography (AS-OCT), as well as gonioscopy and spectral domain OCT (SD-OCT). A secondary objective was to quantify inter-observer agreements of AS-OCT and SD-OCT assessments. METHODS Seventeen consecutive subjects (33 eyes) were recruited from the study hospital's Glaucoma clinic. Gonioscopy was performed by a glaucomatologist masked to OCT results. OCT images were read independently by 2 other glaucomatologists masked to gonioscopy findings as well as each other's analyses of OCT images. RESULTS Totally 84.8% and 45.5% of scleral spurs were visualized in AS-OCT and SD-OCT images respectively (P<0.01). The agreement for angle closure between AS-OCT and gonioscopy was fair at k=0.31 (95% confidence interval, CI: 0.03-0.59) and k=0.35 (95% CI: 0.07-0.63) for reader 1 and 2 respectively. The agreement for angle closure between SD-OCT and gonioscopy was fair at k=0.21 (95% CI: 0.07-0.49) and slight at k=0.17 (95% CI: 0.08-0.42) for reader 1 and 2 respectively. The inter-reader agreement for angle closure in AS-OCT images was moderate at 0.51 (95% CI: 0.13-0.88). The inter-reader agreement for angle closure in SD-OCT images was slight at 0.18 (95% CI: 0.08-0.45). CONCLUSION Significant proportion of scleral spurs were not visualised with SD-OCT imaging resulting in weaker inter-reader agreements. Identifying other angle landmarks in SD-OCT images will allow more consistent angle closure assessments. Gonioscopy and OCT imaging do not always agree in angle closure assessments but have their own advantages, and should be used together and not exclusively. PMID:25938053

  6. Front lighted optical tooling method and apparatus

    DOEpatents

    Stone, W.J.

    1983-06-30

    An optical tooling method and apparatus uses a front lighted shadowgraphic technique to enhance visual contrast of reflected light. The apparatus includes an optical assembly including a fiducial mark, such as cross hairs, reflecting polarized light with a first polarization, a polarizing element backing the fiducial mark and a reflective surface backing the polarizing element for reflecting polarized light bypassing the fiducial mark and traveling through the polarizing element. The light reflected by the reflecting surface is directed through a second pass of the polarizing element toward the frontal direction with a polarization differing from the polarization of the light reflected by the fiducial mark. When used as a tooling target, the optical assembly may be mounted directly to a reference surface or may be secured in a mounting, such as a magnetic mounting. The optical assembly may also be mounted in a plane defining structure and used as a spherometer in conjunction with an optical depth measuring instrument.

  7. Effects of time-temperature profiles on glow curves of germanium-doped optical fibre

    NASA Astrophysics Data System (ADS)

    Lam, S. E.; Alawiah, A.; Bradley, D. A.; Mohd Noor, N.

    2017-08-01

    The Germanium (Ge) doped silica optical fibres have demonstrated the great potential to be developed as a thermoluminescent (TL) dosimeter that can be used in various applications in radiotherapy, diagnostic radiology, UV dosimetry system and food irradiation industry. Different time-temperature profile (TTP) parameters of the TL reader have been employed by many researchers in various of TL studies. Nevertheless, none of those studies adequately addressed the effects of the reader's preheat temperature and heating rate on the kinetic parameters of the TL glow curve specifically, the Ge-doped silica optical fibres. This research addresses the issue of TTP parameters with special attention to the determination of the kinetic parameters of the glow curve. The glow curve responses were explored and the kinetic parameters were analyzed by the WinGCF software, to show the effect of the preheat temperature and heating rate of the reader on Ge-doped fibre irradiated with 18 Gy of 6 MV photons radiation. The effect of TTP parameters was discussed and compared against the commercial fibre and tailored made fibre of 6 mol% Ge-doped of flat and cylindrical shape. The deconvolution of glow peaks and the kinetic parameters were obtained by the WinGCF software. This enables to fit accurately (1.5%

  8. WE-E-217A-02: Methodologies for Evaluation of Standalone CAD System Performance.

    PubMed

    Sahiner, B

    2012-06-01

    Standalone performance evaluation of a CAD system provides information about the abnormality detection or classification performance of the computerized system alone. Although the performance of the reader with CAD is the final step in CAD system assessment, standalone performance evaluation is an important component for several reasons: First, standalone evaluation informs the reader about the performance level of the CAD system and may have an impact on how the reader uses the system. Second, it provides essential information to the system designer for algorithm optimization during system development. Third, standalone evaluation can provide a detailed description of algorithm performance (e.g., on subgroups of the population) because a larger data set with more samples from different subgroups can be included in standalone studies compared to reader studies. Proper standalone evaluation of a CAD system involves a number of key components, some of which are shared with the assessment of reader performance with CAD. These include (1) selection of a test data set that allows performance assessment with little or no bias and acceptable uncertainty; (2) a reference standard that indicates disease status as well as the location and extent of disease; (3) a clearly defined method for labeling each CAD mark as a true-positive or false-positive; and (4) a properly selected set of metrics to summarize the accuracy of the computer marks and their corresponding scores. In this lecture, we will discuss various approaches for the key components of standalone CAD performance evaluation listed above, and present some of the recommendations and opinions from the AAPM CAD subcommittee on these issues. Learning Objectives 1. Identify basic components and metrics in the assessment of standalone CAD systems 2. Understand how each component may affect the assessed performance 3. Learn about AAPM CAD subcommittee's opinions and recommendations on factors and metrics related to the evaluation of standalone CAD system performance. © 2012 American Association of Physicists in Medicine.

  9. EDITORIAL: Changes to the journal Changes to the journal

    NASA Astrophysics Data System (ADS)

    Zheludev, Nikolay I.

    2010-01-01

    It is a privilege to be Editor-in-Chief of Journal of Optics at this exciting time when the use of light spearheads the development of new technologies in telecommunications, green energy, manufacturing, medicine and defence, just to mention a few. These technological advances, seen by many as the next photonic technological revolution, are underpinned by fundamental and applied research in the following key directions: Nanophotonics and plasmonics Metamaterials and structured photonic materials Nonlinear and ultrafast optics Photonics at the life science interface Information and communication optics Integrated optics systems and devices Material processing with light Propagation, diffraction and scattering This is where Journal of Optics focuses its attention. This editorial marks the first issue of the journal published under the abbreviated name (shortened from Journal of Optics A: Pure and Applied Optics). The name change is just one of a series of changes introduced in the last year, along with the 8 subject sections listed above and the appointment of Section Editors. With the name change, we will also update the look of the journal by introducing colour cover images which will feature some of the most exciting research in the journal. We have retained many of the journal's original selling points: we are found in thousands of libraries around the world, and will continue our policy of free web access to all papers for 30 days after publication, ensuring broad and unrestricted dissemination of your research results. We will also continue our strong and well respected special issue and topical review programmes and we are always grateful to receive new suggestions for special issues or review articles. Along with the Editorial Board, I would like to thank the authors, referees and readers who have contributed to the success of Journal of Optics. The increasing quality and visibility of the journal, as demonstrated by the dramatic increase in its impact factor in recent years, make it a prime destination for research papers across the field of optics. So, if you're not already part of our community, we hope you'll join us soon by submitting your next research paper to Journal of Optics.

  10. Epigenetic drugs that do not target enzyme activity.

    PubMed

    Owen, Dafydd R; Trzupek, John D

    2014-06-01

    While the installation and removal of epigenetic post-translational modifications or ‘marks’ on both DNA and histone proteins are the tangible outcome of enzymatically catalyzed processes, the role of the epigenetic reader proteins looks, at first, less obvious. As they do not catalyze a chemical transformation or process as such, their role is not enzymatic. However, this does not preclude them from being potential targets for drug discovery as their function is clearly correlated to transcriptional activity and as a class of proteins, they appear to have binding sites of sufficient definition and size to be inhibited by small molecules. This suggests that this third class of epigenetic proteins that are involved in the interpretation of post-translational marks (as opposed to the creation or deletion of marks) may represent attractive targets for drug discovery efforts. This review mainly summarizes selected publications, patent literature and company disclosures on these non-enzymatic epigenetic reader proteins from 2009 to the present. © 2014 Elsevier Ltd . All rights reserved.

  11. An automated wide-field time-gated optically sectioning fluorescence lifetime imaging multiwell plate reader for high-content analysis of protein-protein interactions

    NASA Astrophysics Data System (ADS)

    Alibhai, Dominic; Kumar, Sunil; Kelly, Douglas; Warren, Sean; Alexandrov, Yuriy; Munro, Ian; McGinty, James; Talbot, Clifford; Murray, Edward J.; Stuhmeier, Frank; Neil, Mark A. A.; Dunsby, Chris; French, Paul M. W.

    2011-03-01

    We describe an optically-sectioned FLIM multiwell plate reader that combines Nipkow microscopy with wide-field time-gated FLIM, and its application to high content analysis of FRET. The system acquires sectioned FLIM images in <10 s/well, requiring only ~11 minutes to read a 96 well plate of live cells expressing fluorescent protein. It has been applied to study the formation of immature HIV virus like particles (VLPs) in live cells by monitoring Gag-Gag protein interactions using FLIM FRET of HIV-1 Gag transfected with CFP or YFP. VLP formation results in FRET between closely packed Gag proteins, as confirmed by our FLIM analysis that includes automatic image segmentation.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hao; Lunt, Barry M.; Gates, Richard J.

    A novel write-once-read-many (WORM) optical stack on Mylar tape is proposed as a replacement for magnetic tape for archival data storage. This optical tape contains a cosputtered bismuth–tellurium–selenium (BTS) alloy as the write layer sandwiched between thin, protective films of reactively sputtered carbon. The composition and thickness of the BTS layer were confirmed by Rutherford Backscattering (RBS) and atomic force microscopy (AFM), respectively. The C/BTS/C stack on Mylar was written to/marked by 532 nm laser pulses. Under the same conditions, control Mylar films without the optical stack were unaffected. Marks, which showed craters/movement of the write material, were characterized bymore » optical microscopy and AFM. The threshold laser powers for making marks on C/BTS/C stacks with different thicknesses were explored. Higher quality marks were made with a 60× objective compared to a 40× objective in our marking apparatus. Finally, the laser writing process was simulated with COMSOL.« less

  13. Optical Air Flow Measurements in Flight

    NASA Technical Reports Server (NTRS)

    Bogue, Rodney K.; Jentink, Henk W.

    2004-01-01

    This document has been written to assist the flight-test engineer and researcher in using optical flow measurements in flight applications. The emphasis is on describing tradeoffs in system design to provide desired measurement performance as currently understood. Optical system components are discussed with examples that illustrate the issues. The document concludes with descriptions of optical measurement systems designed for a variety of applications including aeronautics research, airspeed measurement, and turbulence hazard detection. Theoretical discussion is minimized, but numerous references are provided to supply ample opportunity for the reader to understand the theoretical underpinning of optical concepts.

  14. The effect of word length and other sublexical, lexical, and semantic variables on developmental reading deficits.

    PubMed

    De Luca, Maria; Barca, Laura; Burani, Cristina; Zoccolotti, Pierluigi

    2008-12-01

    To examine the effect of word length and several sublexical, and lexico-semantic variables on the reading of Italian children with a developmental reading deficit. Previous studies indicated the role of word length in transparent orthographies. However, several factors that may interact with word length were not controlled for. Seventeen impaired and 34 skilled sixth-grade readers were presented words of different lengths, matched for initial phoneme, bigram frequency, word frequency, age of acquisition, and imageability. Participants were asked to read aloud, as quickly and as accurately as possible. Reaction times at the onset of pronunciation and mispronunciations were recorded. Impaired readers' reaction times indicated a marked effect of word length; in skilled readers, there was no length effect for short words but, rather, a monotonic increase from 6-letter words on. Regression analyses confirmed the role of word length and indicated the influence of word frequency (similar in impaired and skilled readers). No other variables predicted reading latencies. Word length differentially influenced word recognition in impaired versus skilled readers, irrespective of the action of (potentially interfering) sublexical, lexical, and semantic variables. It is proposed that the locus of the length effect is at a perceptual level of analysis. The independent influence of word frequency on the reading performance of both groups of participants indicates the sparing of lexical activation in impaired readers.

  15. Nano-optical information storage induced by the nonlinear saturable absorption effect

    NASA Astrophysics Data System (ADS)

    Wei, Jingsong; Liu, Shuang; Geng, Yongyou; Wang, Yang; Li, Xiaoyi; Wu, Yiqun; Dun, Aihuan

    2011-08-01

    Nano-optical information storage is very important in meeting information technology requirements. However, obtaining nanometric optical information recording marks by the traditional optical method is difficult due to diffraction limit restrictions. In the current work, the nonlinear saturable absorption effect is used to generate a subwavelength optical spot and to induce nano-optical information recording and readout. Experimental results indicate that information marks below 100 nm are successfully recorded and read out by a high-density digital versatile disk dynamic testing system with a laser wavelength of 405 nm and a numerical aperture of 0.65. The minimum marks of 60 nm are realized, which is only about 1/12 of the diffraction-limited theoretical focusing spot. This physical scheme is very useful in promoting the development of optical information storage in the nanoscale field.

  16. Up-to-date state of storage techniques used for large numerical data files

    NASA Technical Reports Server (NTRS)

    Chlouba, V.

    1975-01-01

    Methods for data storage and output in data banks and memory files are discussed along with a survey of equipment available for this. Topics discussed include magnetic tapes, magnetic disks, Terabit magnetic tape memory, Unicon 690 laser memory, IBM 1360 photostore, microfilm recording equipment, holographic recording, film readers, optical character readers, digital data storage techniques, and photographic recording. The individual types of equipment are summarized in tables giving the basic technical parameters.

  17. Literature and Lives: A Response-Based, Cultural Studies Approach to Teaching English.

    ERIC Educational Resources Information Center

    Carey-Webb, Allen

    Telling stories from secondary and college English classrooms, this book explores the new possibilities for teaching and learning generated by bringing together reader-response and cultural-studies approaches. The book connects William Shakespeare, Charles Dickens, Mark Twain, and other canonical figures to multicultural writers, popular culture,…

  18. Turning Points: Ideas in Books Affecting American Education.

    ERIC Educational Resources Information Center

    Parker, Franklin

    Ideas in ten books which marked turning points in American educational directions are analyzed. William H. McGuffey's "Readers" (1836-44) set the moral and inspirational tone that still exists in American education, though now lessened and mainly in small-town America. "Medical Education in the United States and Canada"…

  19. Lexical Stress Assignment in Italian Developmental Dyslexia

    ERIC Educational Resources Information Center

    Paizi, Despina; Zoccolotti, Pierluigi; Burani, Cristina

    2011-01-01

    Stress assignment to Italian polysyllabic words is unpredictable, because stress is neither marked nor predicted by rule. Stress assignment, especially to low frequency words, has been reported to be a function of stress dominance and stress neighbourhood. Two experiments investigate stress assignment in sixth-grade, skilled and dyslexic, readers.…

  20. Racism and "Huckleberry Finn": Censorship, Dialogue, and Change.

    ERIC Educational Resources Information Center

    Carey-Webb, Allen

    1993-01-01

    Details some of the current critical arguments concerning Mark Twain's depiction of the runaway slave Jim in the novel "Huckleberry Finn." Describes classroom experiences teaching the novel and how a reader's cultural background influences reactions to it. Provides principles and caveats for teaching the novel. Lists works about slavery…

  1. Front lighted optical tooling method and apparatus

    DOEpatents

    Stone, William J.

    1985-06-18

    An optical tooling method and apparatus uses a front lighted shadowgraphic technique to enhance visual contrast of reflected light. The apparatus includes an optical assembly including a fiducial mark, such as cross hairs, reflecting polarized light with a first polarization, a polarizing element backing the fiducial mark and a reflective surface backing the polarizing element for reflecting polarized light bypassing the fiducial mark and traveling through the polarizing element. The light reflected by the reflecting surface is directed through a second pass of the polarizing element toward the frontal direction with a polarization differing from the polarization of the light reflected by the fiducial mark. When used as a tooling target, the optical assembly may be mounted directly to a reference surface or may be secured in a mounting, such as a magnetic mounting. The optical assembly may also be mounted in a plane defining structure and used as a spherometer in conjunction with an optical depth measuring instrument. A method of measuring a radius of curvature of an unknown surface includes positioning the spherometer on a surface between the surface and a depth measuring optical instrument. As the spherometer is frontally illuminated, the distance from the depth measuring instrument to the fiducial mark and the underlying surface are alternately measured and the difference in these measurements is used as the sagittal height to calculate a radius of curvature.

  2. Fabrication and optimisation of a fused filament 3D-printed microfluidic platform

    NASA Astrophysics Data System (ADS)

    Tothill, A. M.; Partridge, M.; James, S. W.; Tatam, R. P.

    2017-03-01

    A 3D-printed microfluidic device was designed and manufactured using a low cost (2000) consumer grade fusion deposition modelling (FDM) 3D printer. FDM printers are not typically used, or are capable, of producing the fine detailed structures required for microfluidic fabrication. However, in this work, the optical transparency of the device was improved through manufacture optimisation to such a point that optical colorimetric assays can be performed in a 50 µl device. A colorimetric enzymatic cascade assay was optimised using glucose oxidase and horseradish peroxidase for the oxidative coupling of aminoantipyrine and chromotropic acid to produce a blue quinoneimine dye with a broad absorbance peaking at 590 nm for the quantification of glucose in solution. For comparison the assay was run in standard 96 well plates with a commercial plate reader. The results show the accurate and reproducible quantification of 0-10 mM glucose solution using a 3D-printed microfluidic optical device with performance comparable to that of a plate reader assay.

  3. Artificial fingerprint recognition by using optical coherence tomography with autocorrelation analysis.

    PubMed

    Cheng, Yezeng; Larin, Kirill V

    2006-12-20

    Fingerprint recognition is one of the most widely used methods of biometrics. This method relies on the surface topography of a finger and, thus, is potentially vulnerable for spoofing by artificial dummies with embedded fingerprints. In this study, we applied the optical coherence tomography (OCT) technique to distinguish artificial materials commonly used for spoofing fingerprint scanning systems from the real skin. Several artificial fingerprint dummies made from household cement and liquid silicone rubber were prepared and tested using a commercial fingerprint reader and an OCT system. While the artificial fingerprints easily spoofed the commercial fingerprint reader, OCT images revealed the presence of them at all times. We also demonstrated that an autocorrelation analysis of the OCT images could be potentially used in automatic recognition systems.

  4. Artificial fingerprint recognition by using optical coherence tomography with autocorrelation analysis

    NASA Astrophysics Data System (ADS)

    Cheng, Yezeng; Larin, Kirill V.

    2006-12-01

    Fingerprint recognition is one of the most widely used methods of biometrics. This method relies on the surface topography of a finger and, thus, is potentially vulnerable for spoofing by artificial dummies with embedded fingerprints. In this study, we applied the optical coherence tomography (OCT) technique to distinguish artificial materials commonly used for spoofing fingerprint scanning systems from the real skin. Several artificial fingerprint dummies made from household cement and liquid silicone rubber were prepared and tested using a commercial fingerprint reader and an OCT system. While the artificial fingerprints easily spoofed the commercial fingerprint reader, OCT images revealed the presence of them at all times. We also demonstrated that an autocorrelation analysis of the OCT images could be potentially used in automatic recognition systems.

  5. Thousand-fold fluorescent signal amplification for mHealth diagnostics

    PubMed Central

    Balsam, Joshua; Rasooly, Reuven; Bruck, Hugh Alan; Rasooly, Avraham

    2013-01-01

    The low sensitivity of Mobile Health (mHealth) optical detectors, such as those found on mobile phones, is a limiting factor for many mHealth clinical applications. To improve sensitivity, we have combined two approaches for optical signal amplification: (1) a computational approach based on an image stacking algorithm to decrease the image noise and enhance weak signals, and (2) an optical signal amplifier utilizing a capillary tube array. These approaches were used in a detection system which includes a multi-wavelength LEDs capable of exciting many fluorophores in multiple wavelengths, a mobile phone or a webcam as a detector, and capillary tube array configured with 36 capillary tubes for signal enhancement. The capillary array enables a ~100X increase in signal sensitivity for fluorescein, reducing the limit of detection (LOD) for mobile phones and webcams from 1000 nM to 10 nM. Computational image stacking enables another ~10X increase in signal sensitivity, further reducing the LOD for webcam from 10 nM to 1 nM. To demonstrate the feasibility of the device for the detection of disease-related biomarkers, Adenovirus DNA labeled with SYBR Green or fluorescein was analyzed by both our capillary array and a commercial plate reader. The LOD for the capillary array was 5ug/mL, and that of the plate reader was 1 ug/mL. Similar results were obtained using DNA stained with fluorescein. The combination of the two signal amplification approaches enables a ~1000X increase in LOD for the webcam platform. This brings it into the range of a conventional plate reader while using a smaller sample volume (10ul) than the plate reader requires (100 ul). This suggests that such a device could be suitable for biosensing applications where up to 10 fold smaller sample sizes are needed. The simple optical configuration for mHealth described in this paper employing the combined capillary and image processing signal amplification is capable of measuring weak fluorescent signals without the need of dedicated laboratories. It has the potential to be used to increase sensitivity of other optically based mHealth technologies, and may increase mHealth’s clinical utility, especially for telemedicine and for resource-poor settings and global health applications. PMID:23928092

  6. Thousand-fold fluorescent signal amplification for mHealth diagnostics.

    PubMed

    Balsam, Joshua; Rasooly, Reuven; Bruck, Hugh Alan; Rasooly, Avraham

    2014-01-15

    The low sensitivity of Mobile Health (mHealth) optical detectors, such as those found on mobile phones, is a limiting factor for many mHealth clinical applications. To improve sensitivity, we have combined two approaches for optical signal amplification: (1) a computational approach based on an image stacking algorithm to decrease the image noise and enhance weak signals, and (2) an optical signal amplifier utilizing a capillary tube array. These approaches were used in a detection system which includes multi-wavelength LEDs capable of exciting many fluorophores in multiple wavelengths, a mobile phone or a webcam as a detector, and capillary tube array configured with 36 capillary tubes for signal enhancement. The capillary array enables a ~100× increase in signal sensitivity for fluorescein, reducing the limit of detection (LOD) for mobile phones and webcams from 1000 nM to 10nM. Computational image stacking enables another ~10× increase in signal sensitivity, further reducing the LOD for webcam from 10nM to 1 nM. To demonstrate the feasibility of the device for the detection of disease-related biomarkers, adenovirus DNA labeled with SYBR green or fluorescein was analyzed by both our capillary array and a commercial plate reader. The LOD for the capillary array was 5 ug/mL, and that of the plate reader was 1 ug/mL. Similar results were obtained using DNA stained with fluorescein. The combination of the two signal amplification approaches enables a ~1000× increase in LOD for the webcam platform. This brings it into the range of a conventional plate reader while using a smaller sample volume (10 ul) than the plate reader requires (100 ul). This suggests that such a device could be suitable for biosensing applications where up to 10 fold smaller sample sizes are needed. The simple optical configuration for mHealth described in this paper employing the combined capillary and image processing signal amplification is capable of measuring weak fluorescent signals without the need of dedicated laboratories. It has the potential to be used to increase sensitivity of other optically based mHealth technologies, and may increase mHealth's clinical utility, especially for telemedicine and for resource-poor settings and global health applications. Published by Elsevier B.V.

  7. Diagnostic accuracy of mammography readers and their memory performance have no correlation with each other.

    PubMed

    Kok, P; Pitman, A G; Cawson, J N; Gledhill, S; Kremer, S; Lawson, J; Mehta, K; Mercuri, V; Shnier, D; Taft, R; Zentner, L

    2010-08-01

    The study aims to determine if any association exists between visual memory performance and diagnostic accuracy performance in a group of radiologist mammogram readers. One hundred proven mammograms (23 with cancers) were grouped into 5 sets of 20 cases, with sets being of equal difficulty. Pairs of sets were presented in 5 reads (40 cases per read, order random) to a panel of 8 radiologist readers (either present or past screening readers, with experience range from <1 year to >20 years). The readers were asked to either 'clear' or 'call back' cases depending on need for further workup, and at post-baseline reads to indicate whether each case was 'new' or 'old' (i.e. remembered from prior read). Two sets were presented only at baseline (40 cases per reader), and were used to calculate the reader's false recollection rate. Three sets were repeated post-baseline once or twice (100 cases per reader). Reading conditions were standardised. Memory performance differed markedly between readers. The number of correctly remembered cases (of 100 'old' cases) had a median of 10.5 and range of 0-58. The observed number of false recollections (of 40 'totally new' cases) had a median of 2 and range of 0-17. Diagnostic performance measures were mean (range): sensitivity 0.68 (0.54-0.81); specificity 0.82 (0.74-0.91); positive predictive value (PPV) 0.55 (0.50-0.65); negative predictive value (NPV) 0.89 (0.86-0.93) and accuracy 0.78 (0.76-0.83). Confidence intervals (CIs; 95%) for each reader overlapped for all the diagnostic parameters, indicating a lack of statistically significant difference between the readers at the 5% level. The most sensitive and the most specific reader showed a trend away from each other on sensitivity, specificity, NPV and PPV; their accuracies were 0.76 and 0.82, respectively, and their accuracy 95% CIs overlapped considerably. Correlation analysis by reader showed no association between observed memory performance and any of the diagnostic accuracy measures in our group of readers. In particular, there was no correlation between diagnostic accuracy and memory performance. There was no association between visual memory performance and diagnostic accuracy as a screening mammographer in our group of eight representative readers. Whether a radiologist has a good or a bad visual memory for cases, and in particular mammograms, should not impact on his or her performance as a radiologist and mammogram reader.

  8. 3-D Index Distribution for Generalized Optical Measurement

    DTIC Science & Technology

    2016-12-01

    AFRL-RY-WP-TR-2016-0179 3-D INDEX DISTRIBUTION FOR GENERALIZED OPTICAL MEASUREMENT Mark Neifeld University of Arizona...DISTRIBUTION FOR GENERALIZED OPTICAL MEASUREMENT 5a. CONTRACT NUMBER FA8650-14-1-7408 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 69199E Mark...Clearance Date7 December 2016.Report contains color. 14. ABSTRACT Optical measurement is central to a wide range of military and commercial applications

  9. Optical Issues in Measuring Strabismus

    PubMed Central

    Irsch, Kristina

    2015-01-01

    Potential errors and complications during examination and treatment of strabismic patients can be reduced by recognition of certain optical issues. This articles reviews basic as well as guiding principles of prism optics and optics of the eye to equip the reader with the necessary know-how to avoid pitfalls that are commonly encountered when using prisms to measure ocular deviations (e.g., during cover testing), and when observing the corneal light reflex to estimate ocular deviations (e.g., during Hirschberg or Krimsky testing in patients who do not allow for cover testing using prisms). PMID:26180462

  10. Optical Issues in Measuring Strabismus.

    PubMed

    Irsch, Kristina

    2015-01-01

    Potential errors and complications during examination and treatment of strabismic patients can be reduced by recognition of certain optical issues. This articles reviews basic as well as guiding principles of prism optics and optics of the eye to equip the reader with the necessary know-how to avoid pitfalls that are commonly encountered when using prisms to measure ocular deviations (e.g., during cover testing), and when observing the corneal light reflex to estimate ocular deviations (e.g., during Hirschberg or Krimsky testing in patients who do not allow for cover testing using prisms).

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarez, P; Gonzalez, S; McDonald, L

    Purpose: Analysis of the performance of the microSTARii reader for optically stimulated luminescence dosimeters (OSLD) used by the IROC Houston Quality Assurance Center (IROC HQAC) for external audits compare to the characteristics of the Microstar reader. Methods: The IROC HQAC uses the Microstar reader for the OSLD program for verification of output of photon, electron and proton beams. The calculation of dose from the OSLD system is based on a group of factors defined at time of the commissioning of a batch of detectors. Factors like system sensitivity (SS), depletion (KD), element correction factor (ECF), linearity (KL), energy correction (KE).more » The new microSTARii unit presents many hardware and software upgrades that were considered useful for this program. Based on these changes many factors, that were considered reader dependent, were revised in order to analyze the effect of the new reading process. The SS, KD, ECF and KL were evaluated and compared with data defined based on reading done on Microstar reader. Results: The SS is reader specific and specified at 100 cGy dose level. This value is define per reading session and monitored over time. The KD factor was found to be different because of reading procedure are different. The ECF values changed for a group of nano dots compare to values defined based on reading done on the Microstar reader. The KL was defined for the reader. Conclusion: The new microSTARii reader presents new features that improve the efficiency of the OSLD program at the IROC HQAC. New characterization is needed before final implementation is done to match the requirements of the existing OSLD system defined for the Microstar reader. Changes in uncertainty of the results has not been analized.« less

  12. The Compensatory Effectiveness of Optical Character Recognition/Speech Synthesis on Reading Comprehension of Postsecondary Students with Learning Disabilities.

    ERIC Educational Resources Information Center

    Higgins, Eleanor L.; Raskind, Marshall H.

    1997-01-01

    Thirty-seven college students with learning disabilities were given a reading comprehension task under the following conditions: (1) using an optical character recognition/speech synthesis system; (2) having the text read aloud by a human reader; or (3) reading silently without assistance. Findings indicated that the greater the disability, the…

  13. Mobile Phone Ratiometric Imaging Enables Highly Sensitive Fluorescence Lateral Flow Immunoassays without External Optical Filters.

    PubMed

    Shah, Kamal G; Singh, Vidhi; Kauffman, Peter C; Abe, Koji; Yager, Paul

    2018-05-14

    Paper-based diagnostic tests based on the lateral flow immunoassay concept promise low-cost, point-of-care detection of infectious diseases, but such assays suffer from poor limits of detection. One factor that contributes to poor analytical performance is a reliance on low-contrast chromophoric optical labels such as gold nanoparticles. Previous attempts to improve the sensitivity of paper-based diagnostics include replacing chromophoric labels with enzymes, fluorophores, or phosphors at the expense of increased fluidic complexity or the need for device readers with costly optoelectronics. Several groups, including our own, have proposed mobile phones as suitable point-of-care readers due to their low cost, ease of use, and ubiquity. However, extant mobile phone fluorescence readers require costly optical filters and were typically validated with only one camera sensor module, which is inappropriate for potential point-of-care use. In response, we propose to couple low-cost ultraviolet light-emitting diodes with long Stokes-shift quantum dots to enable ratiometric mobile phone fluorescence measurements without optical filters. Ratiometric imaging with unmodified smartphone cameras improves the contrast and attenuates the impact of excitation intensity variability by 15×. Practical application was shown with a lateral flow immunoassay for influenza A with nucleoproteins spiked into simulated nasal matrix. Limits of detection of 1.5 and 2.6 fmol were attained on two mobile phones, which are comparable to a gel imager (1.9 fmol), 10× better than imaging gold nanoparticles on a scanner (18 fmol), and >2 orders of magnitude better than gold nanoparticle-labeled assays imaged with mobile phones. Use of the proposed filter-free mobile phone imaging scheme is a first step toward enabling a new generation of highly sensitive, point-of-care fluorescence assays.

  14. Integrated optical sensing of dissolved oxygen in microtiter plates: a novel tool for microbial cultivation.

    PubMed

    John, Gernot T; Klimant, Ingo; Wittmann, Christoph; Heinzle, Elmar

    2003-03-30

    Microtiter plates with integrated optical sensing of dissolved oxygen were developed by immobilization of two fluorophores at the bottom of 96-well polystyrene microtiter plates. The oxygen-sensitive fluorophore responded to dissolved oxygen concentration, whereas the oxygen-insensitive one served as an internal reference. The sensor measured dissolved oxygen accurately in optically well-defined media. Oxygen transfer coefficients, k(L)a, were determined by a dynamic method in a commercial microtiter plate reader with an integrated shaker. For this purpose, the dissolved oxygen was initially depleted by the addition of sodium dithionite and, by oxygen transfer from air, it increased again after complete oxidation of dithionite. k(L)a values in one commercial reader were about 10 to 40 h(-1). k(L)a values were inversely proportional to the filling volume and increased with increasing shaking intensity. Dissolved oxygen was monitored during cultivation of Corynebacterium glutamicum in another reader that allowed much higher shaking intensity. Growth rates determined from optical density measurement were identical to those observed in shaking flasks and in a stirred fermentor. Oxygen uptake rates measured in the stirred fermentor and dissolved oxygen concentrations measured during cultivation in the microtiter plate were used to estimate k(L)a values in a 96-well microtiter plate. The resulting values were about 130 h(-1), which is in the lower range of typical stirred fermentors. The resulting maximum oxygen transfer rate was 26 mM h(-1). Simulations showed that the errors caused by the intermittent measurement method were insignificant under the prevailing conditions. Copyright 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 81: 829-836, 2003.

  15. 'Shaped like a Question Mark': Found Poetry from Herbert Blau's "The Audience"

    ERIC Educational Resources Information Center

    Prendergast, Monica

    2004-01-01

    Performance theorist Herbert Blau's "The Audience" (Baltimore and London, Johns Hopkins Press, 1990) is an important yet neglected theoretical text on theatre audience. Deconstructive, dense and allusive in nature, Blau's text creates a real challenge for his reader. This paper presents a study of "The Audience" employing what I am calling…

  16. "A Nation at Risk" at 25

    ERIC Educational Resources Information Center

    Borek, Jennifer

    2008-01-01

    To introduce this special section marking the 25th anniversary of the publication of "A Nation at Risk," the author contemplates the document's lasting impact and refreshes readers' memories about the problems it defined and the recommendations it offered. In April of 1983, "A Nation at Risk: The Imperative for Educational Reform" was unveiled.…

  17. Transfer of Perceptual Expertise: The Case of Simplified and Traditional Chinese Character Recognition

    ERIC Educational Resources Information Center

    Liu, Tianyin; Chuk, Tin Yim; Yeh, Su-Ling; Hsiao, Janet H.

    2016-01-01

    Expertise in Chinese character recognition is marked by reduced holistic processing (HP), which depends mainly on writing rather than reading experience. Here we show that, while simplified and traditional Chinese readers demonstrated a similar level of HP when processing characters shared between the simplified and traditional scripts, simplified…

  18. The Wright Stuff: Examining the Centennial of Flight

    ERIC Educational Resources Information Center

    Groce, Robin D.; Groce, Eric C.; Stooksberry, Lisa M.

    2004-01-01

    Several new books detailing various aspects of the lives and accomplishments of Wilbur and Orville Wright were written to mark the centennial of their famous 1902 entry into manned flight. This article describes eight books that are appropriate for early- to intermediate-level readers: (1) "Touching the Sky. The Flying Adventures of Wilbur and…

  19. CT Colonography with Computer-aided Detection: Recognizing the Causes of False-Positive Reader Results

    PubMed Central

    Dachman, Abraham H.; Wroblewski, Kristen; Vannier, Michael W.; Horne, John M.

    2014-01-01

    Computed tomography (CT) colonography is a screening modality used to detect colonic polyps before they progress to colorectal cancer. Computer-aided detection (CAD) is designed to decrease errors of detection by finding and displaying polyp candidates for evaluation by the reader. CT colonography CAD false-positive results are common and have numerous causes. The relative frequency of CAD false-positive results and their effect on reader performance on the basis of a 19-reader, 100-case trial shows that the vast majority of CAD false-positive results were dismissed by readers. Many CAD false-positive results are easily disregarded, including those that result from coarse mucosa, reconstruction, peristalsis, motion, streak artifacts, diverticulum, rectal tubes, and lipomas. CAD false-positive results caused by haustral folds, extracolonic candidates, diminutive lesions (<6 mm), anal papillae, internal hemorrhoids, varices, extrinsic compression, and flexural pseudotumors are almost always recognized and disregarded. The ileocecal valve and tagged stool are common sources of CAD false-positive results associated with reader false-positive results. Nondismissable CAD soft-tissue polyp candidates larger than 6 mm are another common cause of reader false-positive results that may lead to further evaluation with follow-up CT colonography or optical colonoscopy. Strategies for correctly evaluating CAD polyp candidates are important to avoid pitfalls from common sources of CAD false-positive results. ©RSNA, 2014 PMID:25384290

  20. Pattern recognition technique

    NASA Technical Reports Server (NTRS)

    Hong, J. P.

    1971-01-01

    Technique operates regardless of pattern rotation, translation or magnification and successfully detects out-of-register patterns. It improves accuracy and reduces cost of various optical character recognition devices and page readers and provides data input to computer.

  1. Novel versatile smart phone based Microplate readers for on-site diagnoses.

    PubMed

    Fu, Qiangqiang; Wu, Ze; Li, Xiuqing; Yao, Cuize; Yu, Shiting; Xiao, Wei; Tang, Yong

    2016-07-15

    Microplate readers are important diagnostic instruments, used intensively for various readout test kits (biochemical analysis kits and ELISA kits). However, due to their expensive and non-portability, commercial microplate readers are unavailable for home testing, community and rural hospitals, especially in developing countries. In this study, to provide a field-portable, cost-effective and versatile diagnostic tool, we reported a novel smart phone based microplate reader. The basic principle of this devise relies on a smart phone's optical sensor that measures transmitted light intensities of liquid samples. To prove the validity of these devises, developed smart phone based microplate readers were applied to readout results of various analytical targets. These targets included analanine aminotransferase (ALT; limit of detection (LOD) was 17.54 U/L), alkaline phosphatase (AKP; LOD was 15.56 U/L), creatinine (LOD was 1.35μM), bovine serum albumin (BSA; LOD was 0.0041mg/mL), prostate specific antigen (PSA; LOD was 0.76pg/mL), and ractopamine (Rac; LOD was 0.31ng/mL). The developed smart phone based microplate readers are versatile, portable, and inexpensive; they are unique because of their ability to perform under circumstances where resources and expertize are limited. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. WE-E-18A-04: Precision In-Vivo Dosimetry Using Optically Stimulated Luminescence Dosimeters and a Pulsed-Stimulating Dose Reader

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Q; Herrick, A; Hoke, S

    Purpose: A new readout technology based on pulsed optically stimulating luminescence is introduced (microSTARii, Landauer, Inc, Glenwood, IL60425). This investigation searches for approaches that maximizes the dosimetry accuracy in clinical applications. Methods: The sensitivity of each optically stimulated luminescence dosimeter (OSLD) was initially characterized by exposing it to a given radiation beam. After readout, the luminescence signal stored in the OSLD was erased by exposing its sensing area to a 21W white LED light for 24 hours. A set of OSLDs with consistent sensitivities was selected to calibrate the dose reader. Higher order nonlinear curves were also derived from themore » calibration readings. OSLDs with cumulative doses below 15 Gy were reused. Before an in-vivo dosimetry, the OSLD luminescence signal was erased with the white LED light. Results: For a set of 68 manufacturer-screened OSLDs, the measured sensitivities vary in a range of 17.3%. A sub-set of the OSLDs with sensitivities within ±1% was selected for the reader calibration. Three OSLDs in a group were exposed to a given radiation. Nine groups were exposed to radiation doses ranging from 0 to 13 Gy. Additional verifications demonstrated that the reader uncertainty is about 3%. With an external calibration function derived by fitting the OSLD readings to a 3rd-order polynomial, the dosimetry uncertainty dropped to 0.5%. The dose-luminescence response curves of individual OSLDs were characterized. All curves converge within 1% after the sensitivity correction. With all uncertainties considered, the systematic uncertainty is about 2%. Additional tests emulating in-vivo dosimetry by exposing the OSLDs under different radiation sources confirmed the claim. Conclusion: The sensitivity of individual OSLD should be characterized initially. A 3rd-order polynomial function is a more accurate representation of the dose-luminescence response curve. The dosimetry uncertainty specified by the manufacturer is 4%. Following the proposed approach, it can be controlled to 2%.« less

  3. Improved cancer detection in automated breast ultrasound by radiologists using Computer Aided Detection.

    PubMed

    van Zelst, J C M; Tan, T; Platel, B; de Jong, M; Steenbakkers, A; Mourits, M; Grivegnee, A; Borelli, C; Karssemeijer, N; Mann, R M

    2017-04-01

    To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n=40) with >1year of follow up, benign (n=30) lesions that were either biopsied or remained stable, and malignant lesions (n=20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p=0.001). Sensitivity of all readers improved (range 5.2-10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4-5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. History of optical theory of reflecting telescopes and implications for future projects

    NASA Astrophysics Data System (ADS)

    Wilson, Raymond N.

    1997-03-01

    This contribution, The History of Optical Theory of Reflecting Telescopes and Implications for Future Projects, is a shortened form of the Karl Schwarzschild lecture given in Bochum in September 1993. Some material has been added from an invited paper given in Padua in December 1992. For a full account, with figures and tables, the reader is referred to these two papers.

  5. Item Unique Identification (IUID) Marking for a Littoral Combat Ship (LCS) Class Mission Module (MM) at the Mission Package Support Facility (MPSF): Implementation Analysis and Development of Optimal Marking Procedures

    DTIC Science & Technology

    2010-06-01

    scanners, readers, or imagers. These types of ADCS devices use two slightly different technologies. Laser scanners use a photodiode to measure the...structure of a ship, but the LCS utilizes modular mission packages that can be removed and replaced when the threat , environment, or mission changes...would need to support a wide array of business applications and users (Clarion, 2009). The DoD’s solution to this deficiency is called IUID. IUID is a

  6. Motor Controller

    NASA Technical Reports Server (NTRS)

    1988-01-01

    M.H. Marks Enterprises' Power Factor Controller (PFC) matches voltage with motor's actual need. Plugged into a motor, PFC continuously determines motor load by sensing shifts between voltage and current flow. When it senses a light load, it cuts voltage to the minimum needed. It offers potential energy savings ranging from eight percent up to 65 percent depending on the application. Myles Marks started out with the notion of writing an article for Popular Electronics magazine at the same time offering to furnish kits to readers interested in assembling PFC's. Within two weeks from publication he had orders for 500 kits and orders are still coming three years later.

  7. Demonstration of Holographic Read-Only-Memory Mastering, Replication, and Playback with a Compact Reader

    NASA Astrophysics Data System (ADS)

    Chuang, Ernest; Sissom, Brad; Harris, Rod; Malang, Keith; Bergman, Chris; Hill, Adrian; Bell, Bernard; Curtis, Kevin

    2008-07-01

    Development prototype systems for holographic read-only-memory (ROM) are demonstrated, capable of high density recording at 406.7 nm wavelength with 0.71 numerical aperture optics. A phase-conjugate Fourier transform lens is developed for improved capacity and tolerances and incorporated into a fully functional compact reader about 1 cm in height. The capacity target for the first generation is 4 Gbytes in a 42×35 mm2 media card. Two-step mastering, replication, and playback are demonstrated for digital audio stored in 125 holograms.

  8. The College Curriculum: A Reader. Adolescent Cultures, School, and Society. Volume 62

    ERIC Educational Resources Information Center

    DeVitis, Joseph L., Ed.

    2013-01-01

    Mark Van Doren, the noted literary scholar, once remarked, "The college is meaningless without a curriculum, but it is more so when it has one that is meaningless." Many current critics of undergraduate curricula in America assent to the crucial need for programmatic renewal in our colleges and universities. They bemoan the cookie-cutter…

  9. PORFIDO on the NEMO Phase 2 tower

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ciaffoni, Orlando; Cordelli, Marco; Habel, Roberto

    We have designed and built an underwater measurement system, PORFIDO (Physical Oceanography by RFID Outreach) to gather oceanographic data from the Optical Modules of a neutrino telescope with a minimum of disturbance to the main installation. PORFIDO is composed of a sensor glued to the outside of an Optical Module, in contact with seawater, and of a reader placed inside the sphere, facing the sensor. Data are transmitted to the reader through the glass by RFID and to shore in real time for periods of years. The sensor gathers power from the radio frequency, thus eliminating the need for batteriesmore » or connectors through the glass. We have deployed four PORFIDO probes measuring temperatures with the NEMO-KM3Net-Italy Phase 2 tower in april 2013. The four probes are operative and are transmitting temperature data from 3500 m depth.« less

  10. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    PubMed

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests that the reader is usable among and can benefit a wide group of potential users, including in POC contexts. Generally, the methodology of this study demonstrates the importance of testing these types of systems with potential users and exemplifies how iterative design processes can be employed by multidisciplinary research teams to produce compelling technological solutions. ©Jess Hohenstein, Dakota O'Dell, Elizabeth L Murnane, Zhengda Lu, David Erickson, Geri Gay. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 21.11.2017.

  11. All over the map: An interobserver agreement study of tumor location based on the PI-RADSv2 sector map.

    PubMed

    Greer, Matthew D; Shih, Joanna H; Barrett, Tristan; Bednarova, Sandra; Kabakus, Ismail; Law, Yan Mee; Shebel, Haytham; Merino, Maria J; Wood, Bradford J; Pinto, Peter A; Choyke, Peter L; Turkbey, Baris

    2018-01-17

    Prostate imaging reporting and data system version 2 (PI-RADSv2) recommends a sector map for reporting findings of prostate cancer mulitparametric MRI (mpMRI). Anecdotally, radiologists may demonstrate inconsistent reproducibility with this map. To evaluate interobserver agreement in defining prostate tumor location on mpMRI using the PI-RADSv2 sector map. Retrospective. Thirty consecutive patients who underwent mpMRI between October, 2013 and March, 2015 and who subsequently underwent prostatectomy with whole-mount processing. 3T mpMRI with T 2 W, diffusion-weighted imaging (DWI) (apparent diffusion coefficient [ADC] and b-2000), dynamic contrast-enhanced (DCE). Six radiologists (two high, two intermediate, and two low experience) from six institutions participated. Readers were blinded to lesion location and detected up to four lesions as per PI-RADSv2 guidelines. Readers marked the long-axis of lesions, saved screen-shots of each lesion, and then marked the lesion location on the PI-RADSv2 sector map. Whole-mount prostatectomy specimens registered to the MRI served as ground truth. Index lesions were defined as the highest grade lesion or largest lesion if grades were equivalent. Agreement was calculated for the exact, overlap, and proportion of agreement. Readers detected an average of 1.9 lesions per patient (range 1.6-2.3). 96.3% (335/348) of all lesions for all readers were scored PI-RADS ≥3. Readers defined a median of 2 (range 1-18) sectors per lesion. Agreement for detecting index lesions by screen shots was 83.7% (76.1%-89.9%) vs. 71.0% (63.1-78.3%) overlap agreement on the PI-RADS sector map (P < 0.001). Exact agreement for defining sectors of detected index lesions was only 21.2% (95% confidence interval [CI]: 14.4-27.7%) and rose to 49.0% (42.4-55.3%) when overlap was considered. Agreement on defining the same level of disease (ie, apex, mid, base) was 61.4% (95% CI 50.2-71.8%). Readers are highly likely to detect the same index lesion on mpMRI, but exhibit poor reproducibility when attempting to define tumor location on the PI-RADSv2 sector map. The poor agreement of the PI-RADSv2 sector map raises concerns its utility in clinical practice. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  12. Wet night visibility of pavement markings.

    DOT National Transportation Integrated Search

    2004-01-01

    This report describes an investigation into the performance of pavement markings in wet night conditions. The performance of a typical pavement marking will degrade when it gets wet. This is a result of the flooding of the marking optics, thereby red...

  13. Book Reviews

    NASA Astrophysics Data System (ADS)

    Horner, Joseph L.

    1987-04-01

    Progress in the fields of integrated optics and fiber optics is continuing at a rapid pace. Recognizing this trend, the goal of the author is to provide an introductory textbook on time-harmonic electromagnetic theory, with an emphasis on optical rather than microwave technologies. The book is appropriate for an upper-level undergraduate or graduate course. Each chapter includes examples of problems. The book focuses on several areas of prime importance to intergrated optics. These include dielectric waveguide analysis, couple-mode thoery, Bragg scattering, and prism coupling There is very little coverage of active components such as electro-optic modulators and switches. The author assumes the reader has a working knowledge of vector calculus and is familiar with Maxwell's equations.

  14. Laser-assisted marking for toric intraocular lens alignment.

    PubMed

    Dick, H Burkhard; Schultz, Tim

    2016-01-01

    We describe a technique of 3-dimensional spectral-domain optical coherence tomography-controlled laser-assisted corneal marking for toric intraocular lens implantation. To facilitate accurate alignment, the technique creates 2 perpendicular intrastromal incisions (width 0.75 mm) using an image-guided femtosecond laser. This was performed in a case series comprising 10 eyes of 10 patients. No posterior corneal perforation or epithelial alterations occurred. The incisions were plainly visible under the operating microscope, and no optical phenomena were reported 6 weeks after surgery. Laser-assisted marking can be performed safely and has the potential to enable precise axis marking. Dr. Dick is a paid consultant to Abbott Medical Optics, Inc. Dr. Schultz has no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Myelin Oligodendrocyte Glycoprotein-IgG-positive Recurrent Bilateral Optic Papillitis with Serous Retinal Detachment: A Case Report.

    PubMed

    Kon, Tomoya; Hikichi, Hiroki; Ueno, Tatsuya; Suzuki, Chieko; Nunomura, Jinichi; Kaneko, Kimihiko; Takahashi, Toshiyuki; Nakashima, Ichiro; Tomiyama, Masahiko

    2018-05-18

    Autoantibodies against myelin oligodendrocyte glycoprotein (MOG-IgG) have been detected in inflammatory demyelinating central nervous system diseases. A 30-year-old woman had blurred vision, marked optic nerve disc swelling, serous retinal detachment at the macular on optic coherence tomography, and MOG-IgG seropositivity. The patient was thought to have optic papillitis associated with MOG-IgG. Her symptoms rapidly improved after high-dose methylprednisolone therapy. We hypothesize that serous retinal detachment was secondary, arising from optic papillitis. This is the first report of the concurrence of optic papillitis with MOG-IgG and serous retinal detachment. MOG-IgG should be tested in patients with marked optic disc swelling.

  16. Formation of bulk refractive index structures

    DOEpatents

    Potter, Jr., Barrett George; Potter, Kelly Simmons; Wheeler, David R.; Jamison, Gregory M.

    2003-07-15

    A method of making a stacked three-dimensional refractive index structure in photosensitive materials using photo-patterning where first determined is the wavelength at which a photosensitive material film exhibits a change in refractive index upon exposure to optical radiation, a portion of the surfaces of the photosensitive material film is optically irradiated, the film is marked to produce a registry mark. Multiple films are produced and aligned using the registry marks to form a stacked three-dimensional refractive index structure.

  17. Coma measurement by use of an alternating phase-shifting mask mark with a specific phase width

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qiu Zicheng; Wang Xiangzhao; Yuan Qiongyan

    2009-01-10

    The correlation between the coma sensitivity of the alternating phase-shifting mask (Alt-PSM) mark and the mark's structure is studied based on the Hopkins theory of partially coherent imaging and positive resist optical lithography (PROLITH) simulation. It is found that an optimized Alt-PSM mark with its phase width being two-thirds its pitch has a higher sensitivity to coma than Alt-PSM marks with the same pitch and the different phase widths. The pitch of the Alt-PSM mark is also optimized by PROLITH simulation, and the structure of p=1.92{lambda}/NA and pw=2p/3 proves to be with the highest sensitivity. The optimized Alt-PSM mark ismore » used as a measurement mark to retrieve coma aberration from the projection optics in lithographic tools. In comparison with an ordinary Alt-PSM mark with its phase width being a half its pitch, the measurement accuracies of Z7 and Z14 apparently increase.« less

  18. Are We "Lucky" for the First Amendment? A Brief History of Students' Right to Read

    ERIC Educational Resources Information Center

    Kelsey, Marie

    2007-01-01

    Winter 2007 marked an episode of high anxiety in the library science profession, when the latest Newbery winner, "The Higher Power of Lucky," triggered discussion about words and their suitability for young readers. It seems that the entire world now knows that the word "scrotum" appears on the first page of the book. School…

  19. Using Torey Hayden's Teacher Stories to Teach Relationship Skills in Special Education Teacher Preparation

    ERIC Educational Resources Information Center

    Hoffman, Elin Meyers; Marlowe, Michael J.; Scharf, Kate Hoffman; Disney, Gayle H.; Macer, Alison; Poling, Daniel; Queen, Amber

    2015-01-01

    Torey Hayden's teacher stories are first-person accounts of being a teacher in classrooms for students with emotional and behavioral disorders. Hayden's books offer readers a real-world look at the joys and challenges of teaching children whose lives are marked by emotional and behavioral disorders, child abuse and trauma, anger and defeat.…

  20. Why AI

    PubMed Central

    Blum, Bruce I.

    1984-01-01

    This is a personal essay. It marks a point in my thinking. The point was chosen by the demands of a schedule; the conclusions, therefore, do not represent a position of resolution in my intellectual odyssey. Indeed, I assume that the SCAMC meeting will mature my views and that (if useful) this paper will be rewritten. Nevertheless, I believe my observations will be of interest to the reader.

  1. Welcome to My House: African American and European American Students' Responses to Virginia Hamilton's "House of Dies Drear."

    ERIC Educational Resources Information Center

    Spears-Bunton, Linda A.

    1990-01-01

    Addresses the relationship between reader response and culture. Presents portraits of a teacher and her Black students and White students as they studied a series of African American literary texts, including Virginia Hamilton's "House of Dies Drear" (1968). The reading of this text marked a turning point for the teacher and students.…

  2. Readers Not Wanted: Student Writers Fight to Keep Their Work off the Web

    ERIC Educational Resources Information Center

    Foster, Andrea L.

    2008-01-01

    Mark Brazaitis worries that his university may sabotage the literary careers of his students. As director of the creative-writing program at West Virginia University, Mr. Brazaitis oversees the training of about 30 graduate students, who hope to become published authors. At the end of their three years in the program, they hand in their magnum…

  3. Action Research: Applying a Bilingual Parallel Corpus Collocational Concordancer to Taiwanese Medical School EFL Academic Writing

    ERIC Educational Resources Information Center

    Reynolds, Barry Lee

    2016-01-01

    Lack of knowledge in the conventional usage of collocations in one's respective field of expertise cause Taiwanese students to produce academic writing that is markedly different than more competent writing. This is because Taiwanese students are first and foremost English as a Foreign language (EFL) readers and may have difficulties picking up on…

  4. Gender Representation in Different Languages and Grammatical Marking on Pronouns: When Beauticians, Musicians, and Mechanics Remain Men

    ERIC Educational Resources Information Center

    Garnham, Alan; Gabriel, Ute; Sarrasin, Oriane; Gygax, Pascal; Oakhill, Jane

    2012-01-01

    Gygax, Gabriel, Sarrasin, Oakhill, and Garnham (2008) showed that readers form a mental representation of gender that is based on grammatical gender in French and German (i.e., masculine supposedly interpretable as a generic form) but is based on stereotypical information in English. In this study, a modification of their stimulus material was…

  5. Comparability Study of Armed Services Vocational Aptitude Battery Scores from Answer Sheet and Answer Card Administration. Final Report.

    ERIC Educational Resources Information Center

    Valentine, Lonnie D., Jr.; Cowan, Douglas K.

    Armed Services Vocational Aptitude Battery (ASVAB) Form 2 was standardized for Digitek answer sheets. In September 1973, the Digitek scoring facility at Randolph AFB will be inadequate to handle anticipated scoring load. Consequently, ASVAB answer forms have been redesigned for processing via a Hewlett-Packard mark-sense reader from IBM card size…

  6. The Centre Is Not in the Middle: Evidence from Line and Word Bisection

    ERIC Educational Resources Information Center

    Arduino, Lisa S.; Previtali, Paola; Girelli, Luisa

    2010-01-01

    English and German readers have been shown to mark a position to the left of the true centre as the subjective midpoint in word bisection. This effect resembles a well-known phenomenon observed with the bisection of solid lines (pseudoneglect), although this behavioural similarity does not imply a common origin. The purpose of the present study…

  7. We the People: Guidelines to Taking Part in Democracy.

    ERIC Educational Resources Information Center

    Vig, Amanda; And Others

    This booklet deals with three ways in which to be an active citizen in a democracy: voting, communicating with elected officials, and volunteering. Words about citizenship that may be new to the reader are in bold print and underlined; a word box at the top of the page provides the meaning of specially marked words on that page. Part 1 on voting…

  8. Arginine methylation-dependent reader-writer interplay governs growth control by E2F-1

    PubMed Central

    Zheng, Shunsheng; Moehlenbrink, Jutta; Lu, Yi-Chien; Zalmas, Lykourgos-Panagiotis; Sagum, Cari A.; Carr, Simon; McGouran, Joanna F.; Alexander, Leila; Fedorov, Oleg; Munro, Shonagh; Kessler, Benedikt; Bedford, Mark T.; Yu, Qiang; La Thangue, Nicholas B.

    2014-01-01

    Summary The mechanisms that underlie and dictate the different biological outcomes of E2F-1 activity have yet to be elucidated. We describe the residue-specific methylation of E2F-1 by the asymmetric dimethylating protein arginine methyltransferase (PRMT) 1 and symmetric dimethylating PRMT5, and relate the marks to different functional consequences of E2F-1 activity. Methylation by PRMT1 hinders methylation by PRMT5, which augments E2F-1-dependent apoptosis, whereas PRMT5-dependent methylation favours proliferation by antagonising methylation by PRMT1. The ability of E2F-1 to prompt apoptosis in DNA damaged cells coincides with enhanced PRMT1 methylation. In contrast, cyclin A binding to E2F-1 impedes PRMT1 methylation and augments PRMT5 methylation, thus ensuring that E2F-1 is locked into its cell cycle progression mode. The Tudor domain protein p100-TSN reads the symmetric methylation mark, and binding of p100-TSN down-regulates E2F-1 apoptotic activity. Our results define an exquisite level of precision in the reader-writer interplay that governs the biological outcome of E2F-1 activity. PMID:24076217

  9. Wet night visibility of pavement markings : executive summary.

    DOT National Transportation Integrated Search

    2004-01-01

    This executive summary describes an investigation into the performance of pavement markings in wet night conditions. The performance of a typical pavement marking will degrade when it gets wet. This is a result of the flooding of the marking optics, ...

  10. QR code based noise-free optical encryption and decryption of a gray scale image

    NASA Astrophysics Data System (ADS)

    Jiao, Shuming; Zou, Wenbin; Li, Xia

    2017-03-01

    In optical encryption systems, speckle noise is one major challenge in obtaining high quality decrypted images. This problem can be addressed by employing a QR code based noise-free scheme. Previous works have been conducted for optically encrypting a few characters or a short expression employing QR codes. This paper proposes a practical scheme for optically encrypting and decrypting a gray-scale image based on QR codes for the first time. The proposed scheme is compatible with common QR code generators and readers. Numerical simulation results reveal the proposed method can encrypt and decrypt an input image correctly.

  11. Electro-optic and acousto-optic scanning and deflection

    NASA Astrophysics Data System (ADS)

    Gottlieb, M.; Ireland, C. L. M.; Ley, J. M.

    This book attempts to cover sufficient electro- and acousto-optic theory for the reader to understand and appreciate the design and application of solid state optical deflectors. It is also hoped that for the more experienced engineer the book will serve as a useful reference book covering the most important work in this field of engineering. The theory of the electro-optic effect is considered along with the properties and selection of electro-optic materials, the principles of electro-optic deflectors, electro-optic deflector designs, and applications for electro-optic deflectors. Attention is given to EM wave propagation in a crystal, the linear electro-optic effect, the quadratic electro-optic effect in crystals and in liquids, electro-optic ceramics in the (Pb,La)(Zr,Ti)O3 system, and digital and analog light deflectors. Aspects related to acousto-optic deflectors are discussed, taking into account acousto-optic interactions, materials for acousto-optic scanning, acoustic techniques, scanning systems, and acousto-optic light diffraction in thin films.

  12. A practical three-dimensional dosimetry system for radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo Pengyi; Adamovics, John; Oldham, Mark

    2006-10-15

    There is a pressing need for a practical three-dimensional (3D) dosimetry system, convenient for clinical use, and with the accuracy and resolution to enable comprehensive verification of the complex dose distributions typical of modern radiation therapy. Here we introduce a dosimetry system that can achieve this challenge, consisting of a radiochromic dosimeter (PRESAGE trade mark sign ) and a commercial optical computed tomography (CT) scanning system (OCTOPUS trade mark sign ). PRESAGE trade mark sign is a transparent material with compelling properties for dosimetry, including insensitivity of the dose response to atmospheric exposure, a solid texture negating the need formore » an external container (reducing edge effects), and amenability to accurate optical CT scanning due to radiochromic optical contrast as opposed to light-scattering contrast. An evaluation of the performance and viability of the PRESAGE trade mark sign /OCTOPUS, combination for routine clinical 3D dosimetry is presented. The performance of the two components (scanner and dosimeter) was investigated separately prior to full system test. The optical CT scanner has a spatial resolution of {<=}1 mm, geometric accuracy within 1 mm, and high reconstruction linearity (with a R{sup 2} value of 0.9979 and a standard error of estimation of {approx}1%) relative to independent measurement. The overall performance of the PRESAGE trade mark sign /OCTOPUS system was evaluated with respect to a simple known 3D dose distribution, by comparison with GAFCHROMIC[reg] EBT film and the calculated dose from a commissioned planning system. The 'measured' dose distribution in a cylindrical PRESAGE trade mark sign dosimeter (16 cm diameter and 11 cm height) was determined by optical-CT, using a filtered backprojection reconstruction algorithm. A three-way Gamma map comparison (4% dose difference and 4 mm distance to agreement), between the PRESAGE trade mark sign , EBT and calculated dose distributions, showed full agreement in measurable region of PRESAGE trade mark sign dosimeter ({approx}90% of radius). The EBT and PRESAGE trade mark sign distributions agreed more closely with each other than with the calculated plan, consistent with penumbral blurring in the planning data which was acquired with an ion chamber. In summary, our results support the conclusion that the PRESAGE trade mark sign optical-CT combination represents a significant step forward in 3D dosimetry, and provides a robust, clinically effective and viable high-resolution relative 3D dosimetry system for radiation therapy.« less

  13. Histone deacetylase inhibition modulates histone acetylation at gene promoter regions and affects genome-wide gene transcription in Schistosoma mansoni

    PubMed Central

    Anderson, Letícia; Gomes, Monete Rajão; daSilva, Lucas Ferreira; Pereira, Adriana da Silva Andrade; Mourão, Marina M.; Romier, Christophe; Pierce, Raymond

    2017-01-01

    Background Schistosomiasis is a parasitic disease infecting hundreds of millions of people worldwide. Treatment depends on a single drug, praziquantel, which kills the Schistosoma spp. parasite only at the adult stage. HDAC inhibitors (HDACi) such as Trichostatin A (TSA) induce parasite mortality in vitro (schistosomula and adult worms), however the downstream effects of histone hyperacetylation on the parasite are not known. Methodology/Principal findings TSA treatment of adult worms in vitro increased histone acetylation at H3K9ac and H3K14ac, which are transcription activation marks, not affecting the unrelated transcription repression mark H3K27me3. We investigated the effect of TSA HDACi on schistosomula gene expression at three different time points, finding a marked genome-wide change in the transcriptome profile. Gene transcription activity was correlated with changes on the chromatin acetylation mark at gene promoter regions. Moreover, combining expression data with ChIP-Seq public data for schistosomula, we found that differentially expressed genes having the H3K4me3 mark at their promoter region in general showed transcription activation upon HDACi treatment, compared with those without the mark, which showed transcription down-regulation. Affected genes are enriched for DNA replication processes, most of them being up-regulated. Twenty out of 22 genes encoding proteins involved in reducing reactive oxygen species accumulation were down-regulated. Dozens of genes encoding proteins with histone reader motifs were changed, including SmEED from the PRC2 complex. We targeted SmEZH2 methyltransferase PRC2 component with a new EZH2 inhibitor (GSK343) and showed a synergistic effect with TSA, significantly increasing schistosomula mortality. Conclusions/Significance Genome-wide gene expression analyses have identified important pathways and cellular functions that were affected and may explain the schistosomicidal effect of TSA HDACi. The change in expression of dozens of histone reader genes involved in regulation of the epigenetic program in S. mansoni can be used as a starting point to look for possible novel schistosomicidal targets. PMID:28406899

  14. Identification of a small-molecule ligand of the epigenetic reader protein Spindlin1 via a versatile screening platform

    PubMed Central

    Wagner, Tobias; Greschik, Holger; Burgahn, Teresa; Schmidtkunz, Karin; Schott, Anne-Kathrin; McMillan, Joel; Baranauskienė, Lina; Xiong, Yan; Fedorov, Oleg; Jin, Jian; Oppermann, Udo; Matulis, Daumantas; Schüle, Roland; Jung, Manfred

    2016-01-01

    Epigenetic modifications of histone tails play an essential role in the regulation of eukaryotic transcription. Writer and eraser enzymes establish and maintain the epigenetic code by creating or removing posttranslational marks. Specific binding proteins, called readers, recognize the modifications and mediate epigenetic signalling. Here, we present a versatile assay platform for the investigation of the interaction between methyl lysine readers and their ligands. This can be utilized for the screening of small-molecule inhibitors of such protein–protein interactions and the detailed characterization of the inhibition. Our platform is constructed in a modular way consisting of orthogonal in vitro binding assays for ligand screening and verification of initial hits and biophysical, label-free techniques for further kinetic characterization of confirmed ligands. A stability assay for the investigation of target engagement in a cellular context complements the platform. We applied the complete evaluation chain to the Tudor domain containing protein Spindlin1 and established the in vitro test systems for the double Tudor domain of the histone demethylase JMJD2C. We finally conducted an exploratory screen for inhibitors of the interaction between Spindlin1 and H3K4me3 and identified A366 as the first nanomolar small-molecule ligand of a Tudor domain containing methyl lysine reader. PMID:26893353

  15. Controlling reactive oxygen species in skin at their source to reduce skin aging.

    PubMed

    Kern, Dale G; Draelos, Zoe D; Meadows, Christiaan; James Morré, D; Morré, Dorothy M

    2010-01-01

    Activity of an age-related, superoxide-forming, cell-surface oxidase (arNOX) comparing dermis, epidermis, serum, and saliva from female and male subjects ages 28-72 years measured spectrophotometrically using reduction of ferricytochrome c correlated with oxidative skin damage as estimated from autofluoresence of skin using an Advanced Glycation End products Reader (AGE-Reader; DiagnOptics B.V., Netherlands). By reducing arNOX activity in skin with arNOX-inhibitory ingredients (NuSkin's ageLOC technology), skin appearance was improved through decreased protein cross-linking and an accelerated increase in collagen.

  16. Does media coverage influence public attitudes towards welfare recipients? The impact of the 2011 English riots.

    PubMed

    Reeves, Aaron; de Vries, Robert

    2016-06-01

    Following the shooting of Mark Duggan by police on 4 August 2011, there were riots in many large cities in the UK. As the rioting was widely perceived to be perpetrated by the urban poor, links were quickly made with Britain's welfare policies. In this paper, we examine whether the riots, and the subsequent media coverage, influenced attitudes toward welfare recipients. Using the British Social Attitudes survey, we use multivariate difference-in-differences regression models to compare attitudes toward welfare recipients among those interviewed before (pre-intervention: i.e. prior to 6 August) and after (post-intervention: 10 August-10 September) the riots occurred (N = 3,311). We use variation in exposure to the media coverage to test theories of media persuasion in the context of attitudes toward welfare recipients. Before the riots, there were no significant differences between newspaper readers and non-readers in their attitudes towards welfare recipients. However, after the riots, attitudes diverged. Newspaper readers became more likely than non-readers to believe that those on welfare did not really deserve help, that the unemployed could find a job if they wanted to and that those on the dole were being dishonest in claiming benefits. Although the divergence was clearest between right-leaning newspaper and non-newspaper readers, we do not a find statistically significant difference between right- and left-leaning newspapers. These results suggest that media coverage of the riots influenced attitudes towards welfare recipients; specifically, newspaper coverage of the riots increased the likelihood that readers of the print media expressed negative attitudes towards welfare recipients when compared with the rest of the population. © London School of Economics and Political Science 2016.

  17. Principles for new optical techniques in medical diagnostics for mHealth applications

    NASA Astrophysics Data System (ADS)

    Balsam, Joshua Michael

    Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.

  18. Computer-aided detection of colorectal polyps: can it improve sensitivity of less-experienced readers? Preliminary findings.

    PubMed

    Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael

    2007-10-01

    To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.

  19. Programmable 10 MHz optical fiducial system for hydrodiagnostic cameras

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huen, T.

    1987-07-01

    A solid state light control system was designed and fabricated for use with hydrodiagnostic streak cameras of the electro-optic type. With its use, the film containing the streak images will have on it two time scales simultaneously exposed with the signal. This allows timing and cross timing. The latter is achieved with exposure modulation marking onto the time tick marks. The purpose of using two time scales will be discussed. The design is based on a microcomputer, resulting in a compact and easy to use instrument. The light source is a small red light emitting diode. Time marking can bemore » programmed in steps of 0.1 microseconds, with a range of 255 steps. The time accuracy is based on a precision 100 MHz quartz crystal, giving a divided down 10 MHz system frequency. The light is guided by two small 100 micron diameter optical fibers, which facilitates light coupling onto the input slit of an electro-optic streak camera. Three distinct groups of exposure modulation of the time tick marks can be independently set anywhere onto the streak duration. This system has been successfully used in Fabry-Perot laser velocimeters for over four years in our Laboratory. The microcomputer control section is also being used in providing optical fids to mechanical rotor cameras.« less

  20. Organizational Self-Awareness in the Key to Knowledge Superiority

    DTIC Science & Technology

    2015-12-01

    needs is physiological, safety, love/belonging, esteem , and self -actualization (Maslow 1943; Simons, Irwin and Drinnien 1987). The major...43 initiative itself is minimal once the decision is made by them to proceed. The stronger impacts are in their esteem and self -actualization needs... SELF -AWARENESS IS THE KEY TO KNOWLEDGE SUPERIORITY by Ricardo Rivera December 2015 Thesis Advisor: Mark E. Nissen Second Reader: Walter

  1. A Swiss Manufacturer Sees the Industrial Revolution in England*

    PubMed Central

    Buess, Heinrich

    1962-01-01

    I have recently come across the diaries of Johann Conrad Fischer. These diaries span six decades and cover the years of social, economic, and technological upheaval which marked the industrial revolution in England. The reader is given a picture of these years through the eyes of a Swiss manufacturer with a good perception of history, and his notes are of some value to historians. PMID:13874462

  2. [P.A.M. Dirac and antimatter applied to medicine].

    PubMed

    Kulenović, Fahrudin; Vobornik, Slavenka; Dalagija, Faruk

    2003-01-01

    Regarding to the hundredth anniversary of P. Dirac birth, it was made review on life and work of this genius in the history of physics and science generally. His ingenious scientific work, that significantly marked contemporary time, was presented in the simplest way with aim to approach more number of readers. Special accent was put on application of Dirac's ideas about antiparticles in medical practice.

  3. Orthographic Transparency Enhances Morphological Segmentation in Children Reading Hebrew Words.

    PubMed

    Haddad, Laurice; Weiss, Yael; Katzir, Tami; Bitan, Tali

    2017-01-01

    Morphological processing of derived words develops simultaneously with reading acquisition. However, the reader's engagement in morphological segmentation may depend on the language morphological richness and orthographic transparency, and the readers' reading skills. The current study tested the common idea that morphological segmentation is enhanced in non-transparent orthographies to compensate for the absence of phonological information. Hebrew's rich morphology and the dual version of the Hebrew script (with and without diacritic marks) provides an opportunity to study the interaction of orthographic transparency and morphological segmentation on the development of reading skills in a within-language design. Hebrew speaking 2nd ( N = 27) and 5th ( N = 29) grade children read aloud 96 noun words. Half of the words were simple mono-morphemic words and half were bi-morphemic derivations composed of a productive root and a morphemic pattern. In each list half of the words were presented in the transparent version of the script (with diacritic marks), and half in the non-transparent version (without diacritic marks). Our results show that in both groups, derived bi-morphemic words were identified more accurately than mono-morphemic words, but only for the transparent, pointed, script. For the un-pointed script the reverse was found, namely, that bi-morphemic words were read less accurately than mono-morphemic words, especially in second grade. Second grade children also read mono-morphemic words faster than bi-morphemic words. Finally, correlations with a standardized measure of morphological awareness were found only for second grade children, and only in bi-morphemic words. These results, showing greater morphological effects in second grade compared to fifth grade children suggest that for children raised in a language with a rich morphology, common and easily segmented morphemic units may be more beneficial for younger compared to older readers. Moreover, in contrast to the common hypothesis, our results show that morphemic segmentation does not compensate for the missing phonological information in a non-transparent orthography, but rather that morphological segmentation is most beneficial in the highly transparent script. These results are consistent with the idea that morphological and phonological segmentation processes occur simultaneously and do not constitute alternative pathways to visual word recognition.

  4. [Deep learning and neuronal networks in ophthalmology : Applications in the field of optical coherence tomography].

    PubMed

    Treder, M; Eter, N

    2018-04-19

    Deep learning is increasingly becoming the focus of various imaging methods in medicine. Due to the large number of different imaging modalities, ophthalmology is particularly suitable for this field of application. This article gives a general overview on the topic of deep learning and its current applications in the field of optical coherence tomography. For the benefit of the reader it focuses on the clinical rather than the technical aspects.

  5. Scanners, optical character readers, Cyrillic alphabet and Russian translations

    NASA Technical Reports Server (NTRS)

    Johnson, Gordon G.

    1995-01-01

    The writing of code for capture, in a uniform format, of bit maps of words and characters from scanner PICT files is presented. The coding of Dynamic Pattern Matched for the identification of the characters, words and sentences in preparation for translation is discussed.

  6. Integrated optics implementation of a fiber optic rotation sensor - Analysis and development. [for Mariner Mark II planetary explorer

    NASA Technical Reports Server (NTRS)

    Bartman, R. K.; Youmans, B. R.; Nerheim, N. M.

    1987-01-01

    The Jet Propulsion Laboratory is developing a fiber optic rotation sensor (FORS) for use on the Mariner Mark II series of planetary explorer craft and in other space applications. FORS is a closed-loop phase-nulling device and embodies a number of interesting innovations. Chief among these are the incorporation of the device's couplers, phase modulators, and polarizer on a single lithium niobate (LinbO3) integrate optics chip and a novel means of reading out angular position and rotation rate based on optical beat detection. Various aspects of the FORS design and operation are described and discussed. Particular attention is paid to analyzing errors attributable to polarizer imperfection and the so-called residual Michelson effect.

  7. 77 FR 53830 - Retirement of FASTforward

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-04

    ... States Postal Service, Domestic Mail Manual (DMM[supreg]) 602.5.0 to terminate the use of FASTforward...-address system, was developed in 1996 to enable Multi-Line Optical Character Reader (MLOCR) users a means... the following changes to Mailing Standards of the United States Postal Service, Domestic Mail Manual...

  8. Fundamental concepts of integrated and fiber optic sensors

    NASA Technical Reports Server (NTRS)

    Tuma, Margaret L.

    1995-01-01

    This chapter discusses fiber optic and integrated optic sensor concepts. Unfortunately, there is no standard method to categorize these sensor concepts. Here, fiber optic and integrated optic sensor concepts will be categorized by the primary modulation technique. These modulation techniques have been classified as: intensity, phase, wavelength, polarization, and time/frequency modulation. All modulate the output light with respect to changes in the physical or chemical property to be measured. Each primary modulation technique is then divided into fiber optic and integrated optic sections which are treated independently. For each sensor concept, possible sensor applications are discussed. The sensors and references discussed are not exhaustive, but sufficient to give the reader an overview of sensor concepts developed to date. Sensor multiplexing techniques such as wavelength division, time division, and frequency division will not be discussed as they are beyond the scope of this report.

  9. The News Media Industry

    DTIC Science & Technology

    2003-06-05

    into “infotainment,” with an emphasis on trivia and news of the lives of celebrities. As a result, the American public is, as media critic Mark...presented by multiple outlets is often recycled . For example, a reader of Newsweek may see a similar, if not identical, story in its sibling...teleprompter. News and entertainment have morphed into “infotainment,” with an emphasis on trivia and the lives of celebrities. Unfortunately

  10. Jitter model and signal processing techniques for pulse width modulation optical recording

    NASA Technical Reports Server (NTRS)

    Liu, Max M.-K.

    1991-01-01

    A jitter model and signal processing techniques are discussed for data recovery in Pulse Width Modulation (PWM) optical recording. In PWM, information is stored through modulating sizes of sequential marks alternating in magnetic polarization or in material structure. Jitter, defined as the deviation from the original mark size in the time domain, will result in error detection if it is excessively large. A new approach is taken in data recovery by first using a high speed counter clock to convert time marks to amplitude marks, and signal processing techniques are used to minimize jitter according to the jitter model. The signal processing techniques include motor speed and intersymbol interference equalization, differential and additive detection, and differential and additive modulation.

  11. Add-Ons: The Ultimate Guide to Peripherals for the Blind Computer User.

    ERIC Educational Resources Information Center

    Croft, Diane L., Ed.

    Detailed product information on peripherals for the blind computer user is provided and applications, availability, reliability, price, and selection considerations are described. Chapters address the following topics and product categories: (1) scanners (optical character readers, Kurzweil Reading Machine); (2) a buyer's guide to modems; (3)…

  12. Thermoluminescence characteristics of flat optical fiber in radiation dosimetry under different electron irradiation conditions

    NASA Astrophysics Data System (ADS)

    Alawiah, A.; Intan, A. M.; Bauk, S.; Abdul-Rashid, H. A.; Yusoff, Z.; Mokhtar, M. R.; Wan Abdullah, W. S.; Mat Sharif, K. A.; Mahdiraji, G. A.; Mahamd Adikan, F. R.; Tamchek, N.; Noor, N. M.; Bradley, D. A.

    2013-05-01

    Thermoluminescence (TL) flat optical fibers (FF) have been proposed as radiation sensor in medical dosimetry for both diagnostic and radiotherapy applications. A flat optical fiber with nominal dimensions of (3.226 × 3.417 × 0.980) mm3 contains pure silica SiO2 was selected for this research. The FF was annealed at 400°C for 1 h before irradiated. Kinetic parameters and dosimetric glow curve of TL response were studied in FF with respect to electron irradiation of 6 MeV, 15 MeV and 21 MeV using linear accelerator (LINAC) in the dose range of 2.0-10.0 Gy. The TL response was read using a TLD reader Harshaw Model 3500. The Time-Temperature-Profile (TTP) of the reader used includes; initial preheat temperature of 80°C, maximum readout temperature is 400°C and the heating rate of 30°Cs-1. The proposed FF shows excellent linear radiation response behavior within the clinical relevant dose range for all of these energies, good reproducibility, independence of radiation energy, independence of dose rate and exhibits a very low thermal fading. From these results, the proposed FF can be used as radiation dosimeter and favorably compares with the widely used of LiF:MgTi dosimeter in medical radiotherapy application.

  13. Mass-marking of otoliths of lake trout sac fry by temperature manipulation

    USGS Publications Warehouse

    Bergstedt, Roger A.; Eshenroder, Randy L.; Bowen, Charles; Seelye, James G.; Locke, Jeffrey C.

    1990-01-01

    The otoliths of 676,000 sac fry of lake trout Salvelinus namaycush in 1986, and of 1,100,000 in 1987, were marked by daily manipulation of water temperature. The fish were stocked into Lake Huron in the spring. Otolith marks consisted of groups of daily growth rings accentuated into recognizable patterns by steadily raising and lowering the temperature about 10 degrees C (from a base of 1-4 degrees C) over 14 h. In 1987, groups of marked and control fish were held for 6 months. The otoliths were removed from samples of the fish, embedded in epoxy, thin sectioned by grinding in the sagittal plane, etched, and viewed by using a combination of a compound microscope (400-1000x) and a video enhancement system. One or more readable otolith sections were obtained from 39 of a sample of 40 fish. Three independent readers examined 41 otoliths for marks and correctly classified the otoliths, with accuracies of 85, 98, and 100%, as being from marked or unmarked fish. The exact number of rings in a recognizable pattern sometimes differed from the number of temperature cycles to which the fish were exposed. Counts of daily rings within groups of six rings varied less than counts within groups of rings.

  14. Mass-marking of otoliths of lake trout sac fry by temperature manipulation

    USGS Publications Warehouse

    Bergstedt, R.A.; Eshenroder, R.L.; Bowen, C. II; Seelye, J.G.; Locke, J.C.; Parker, N.C.; Giorgi, A.E.; Heidenger, R.C.; Jester, D. B.; Prince, E.D.; Winans, G.A.

    1990-01-01

    The otoliths of 676,000 sac fry of lake trout Salvelinus namaycush in 1986, and of 1,100,000 in 1987, were marked by daily manipulation of water temperature. The fish were stocked into Lake Huron in the spring. Otolith marks consisted of groups of daily growth rings accentuated into recognizable patterns by steadily raising and lowering the temperature about IOA?C (from a base of 1-4A?C) over 14h. In 1987, groups of marked and control fish were held for 6 months. The otoliths were removed from samples of the fish, embedded in epoxy, thin-sectioned by grinding in the sagittal plane, etched, and viewed by using a combination of a compound microscope (400-1000x) and a video enhancement system. One or more readable otolith sections were obtained from 39 of a sample of 40 fish. Three independent readers examined 41 otoliths for marks and correctly classified the otoliths, with accuracies of 85, 98,and 100%, as being from marked or unmarked fish. The exact number of rings in a recognizable pattern sometimes differed from the number of temperature cycles to which the fish were exposed. Counts of daily rings within groups of six rings varied less than counts within groups of three rings.

  15. Relevance, textual unity, and politeness in writing about science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreml, N.M.P.

    1992-01-01

    The question of whether there are social implications of linguistic choices in unifying a text is investigated empirically by this study which accounts for the interpretation of implicatures in conversation and written texts. It considers Relevance Theory (Sperber and Wilson 1988, Blakemore 1987, Blass 1990) to be the explanation of the unity of the text, as opposed to semantic theories of cohesion (Halliday and Hasan 1976) or pragmatic theories of coherence (van Dijk 1977). This study presents a model of three types of textual unifiers: overt (referring specifically to the text), embedded (referring to intra- and extra-textual information), and inferencemore » (not referring to the text at all). It hypothesizes that different genres are characterized by the predominance of different types of textual unifiers, and that readers will prefer those texts that rely on inferential unifiers which emphasize the reader's ability to participate in creating the meaning of the text. Eighteen texts of 275 words each are selected from three genres: scientific magazines, introductory science textbooks, and essays on science. The texts are found to vary significantly by genre in the type of textual unifier used. An Overtness Index expresses the ratio of the marked forms: science textbooks have more Overt unifiers (such as connective phrases) and thus a high Overtness Index; essays rely more on Inference unifiers (not represented by words) and thus have a low Overtness Index. The texts are submitted to 188 readers, and a significantly high number of all types of readers prefer the texts with the lower Overtness Indices-the essays. Thus a low Overtness Index is one feature of texts preferred by readers, supporting the hypotheses that genres of texts vary in the type of unifier used and that readers prefer texts that allow them to participate in constructing the meaning of the text.« less

  16. Pattern visual evoked potentials in eyes with disc swelling due to cat scratch disease-associated neuroretinitis.

    PubMed

    Chai, Yuzhu; Yamamoto, Shuichi; Hirayama, Atsuko; Yotsukura, Jiro; Yamazaki, Hiroko

    2005-01-01

    To evaluate optic nerve function by pattern visual evoked potentials (VEPs) in eyes with optic disc swelling due to neuroretinitis associated with cat scratch disease (CSD). Four eyes of four patients with marked optic disc swelling resembling optic neuritis but diagnosed serologically as CSD received systemic steroid treatment. VEPs elicited by black and white checkerboard stimuli created on a TV monitor were recorded before the treatment. The visual acuity (VA) in the affected eyes was decreased to 20/50 in two eyes and finger counting in two eyes at their initial visits. Ophthalmoscopic examination revealed neuroretinitis characterized by severe optic disc swelling, chorioretinal exudates, and macular edema in all eyes. Anti-Bartonella henselae serum antibody was markedly elevated in all patients confirming the diagnosis of CSD. The P100 of the transient VEPs was only mildly reduced without a delay in the implicit times in three eyes and only slightly delayed in the other eye. The steady-state VEPs were mildly reduced in two eyes and phase-reversed in other two eyes. The VA fully recovered after systemic steroid treatment in all patients. Although all examined patients showed marked swelling of the optic disc and visual decrease, the pattern VEPs were not affected as severely as in idiopathic optic neuritis. However, the degree of change of the pattern VEPs varied among patients.

  17. Non-localization and localization ROC analyses using clinically based scoring

    NASA Astrophysics Data System (ADS)

    Paquerault, Sophie; Samuelson, Frank W.; Myers, Kyle J.; Smith, Robert C.

    2009-02-01

    We are investigating the potential for differences in study conclusions when assessing the estimated impact of a computer-aided detection (CAD) system on readers' performance. The data utilized in this investigation were derived from a multi-reader multi-case observer study involving one hundred mammographic background images to which fixed-size and fixed-intensity Gaussian signals were added, generating a low- and high-intensity signal sets. The study setting allowed CAD assessment in two situations: when CAD sensitivity was 1) superior or 2) lower than the average reader. Seven readers were asked to review each set in the unaided and CAD-aided reading modes, mark and rate their findings. Using this data, we studied the effect on study conclusion of three clinically-based receiver operating characteristic (ROC) scoring definitions. These scoring definitions included both location-specific and non-location-specific rules. The results showed agreement in the estimated impact of CAD on the overall reader performance. In the study setting where CAD sensitivity is superior to the average reader, the mean difference in AUC between the CAD-aided read and unaided read was 0.049 (95%CIs: -0.027; 0.130) for the image scoring definition that is based on non-location-specific rules, and 0.104 (95%CIs: 0.036; 0.174) and 0.090 (95%CIs: 0.031; 0.155) for image scoring definitions that are based on location-specific rules. The increases in AUC were statistically significant for the location-specific scoring definitions. It was further observed that the variance on these estimates was reduced when using the location-specific scoring definitions compared to that using a non-location-specific scoring definition. In the study setting where CAD sensitivity is equivalent or lower than the average reader, the mean differences in AUC are slightly above 0.01 for all image scoring definitions. These increases in AUC were not statistical significant for any of the image scoring definitions. The results on the variance analysis differed from those observed in the other study setting. This investigation furthers our understanding of the relationships between non-localization-specific and localization-specific ROC assessment methodologies and their relevance to clinical practice.

  18. Delay or deficit? Spelling processes in children with specific language impairment.

    PubMed

    Larkin, Rebecca F; Williams, Gareth J; Blaggan, Samarita

    2013-01-01

    Few studies have explored the phonological, morphological and orthographic spellings skills of children with specific language impairment (SLI) simultaneously. Fifteen children with SLI (mean age=113.07 months, SD=8.61) completed language and spelling tasks alongside chronological-age controls and spelling-age controls. While the children with SLI showed a deficit in phonological spelling, they performed comparably to spelling-age controls on morphological spelling skills, and there were no differences between the three groups in producing orthographically legal spellings. The results also highlighted the potential importance of adequate non-word repetition skills in relation to effective spelling skills, and demonstrated that not all children with spoken language impairments show marked spelling difficulties. Findings are discussed in relation to theory, educational assessment and practice. As a result of this activity, readers will describe components of spoken language that predict children's morphological and phonological spelling performance. As a result of this activity, readers will describe how the spelling skills of children with SLI compare to age-matched and spelling age-matched control children. Readers will be able to interpret the variability in spelling performance seen in children with SLI. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid.

    PubMed

    Wang, Yijia; Zeinhom, Mohamed M A; Yang, Mingming; Sun, Rongrong; Wang, Shengfu; Smith, Jordan N; Timchalk, Charles; Li, Lei; Lin, Yuehe; Du, Dan

    2017-09-05

    Onsite rapid detection of herbicides and herbicide residuals in environmental and biological specimens are important for agriculture, environmental concerns, food safety, and health care. The traditional method for herbicide detection requires expensive laboratory equipment and a long turnaround time. In this work, we developed a single-stripe microliter plate smartphone-based colorimetric device for rapid and low-cost in-field tests. This portable smartphone platform is capable of screening eight samples in a single-stripe microplate. The device combined the advantages of small size (50 × 100 × 160 mm 3 ) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and rhodamine B, for the red and green channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for detection of the herbicide 2,4-dichlorophenoxyacetic acid in the range of 1 to 80 ppb. Spiked samples of tap water, rat serum, plasma, and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all of the spiked samples using the microplate reader and from 93.7% to 106.9% for all of the samples using the smartphone device. This work validated that the smartphone optical-sensing platform is comparable to the commercial microplate reader; it is eligible for onsite, rapid, and low-cost detection of herbicides for environmental evaluation and biological monitoring.

  20. A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yijia; Zeinhom, Mohamed M. A.; Yang, Mingming

    Onsite rapid detection of herbicide and herbicide residuals in environmental and biological specimens is important for agriculture, environment, food safety, and health care. Traditional method for herbicide detection requires expensive laboratory equipment and a long turn-round time. In this work, we developed a single-stripe microliter plate smartphone colorimetric device for rapid and low-cost in-field test. This portable smartphone platform is capable of screening 8 samples in a microplate single-stripe. The device combined the advantages of small size (50×100×160 mm3) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and Rhodamine B,more » for green and red channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for an herbicide, 2,4-Dichlorophenoxyacetic acid detection in the range of 1 ppb to 80 ppb. Spiked samples of tap water, rat serum, plasma and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all spiked samples using the microplate reader and from 93.7% to 106.9% using the smartphone device. This work validated that the smartphone optical sensing platform is comparable to the commercial microplate reader, it is eligible for onsite rapid and low-cost detection of herbicide for environmental evaluation and biological monitoring.« less

  1. Scattering effects of machined optical surfaces

    NASA Astrophysics Data System (ADS)

    Thompson, Anita Kotha

    1998-09-01

    Optical fabrication is one of the most labor-intensive industries in existence. Lensmakers use pitch to affix glass blanks to metal chucks that hold the glass as they grind it with tools that have not changed much in fifty years. Recent demands placed on traditional optical fabrication processes in terms of surface accuracy, smoothnesses, and cost effectiveness has resulted in the exploitation of precision machining technology to develop a new generation of computer numerically controlled (CNC) optical fabrication equipment. This new kind of precision machining process is called deterministic microgrinding. The most conspicuous feature of optical surfaces manufactured by the precision machining processes (such as single-point diamond turning or deterministic microgrinding) is the presence of residual cutting tool marks. These residual tool marks exhibit a highly structured topography of periodic azimuthal or radial deterministic marks in addition to random microroughness. These distinct topographic features give rise to surface scattering effects that can significantly degrade optical performance. In this dissertation project we investigate the scattering behavior of machined optical surfaces and their imaging characteristics. In particular, we will characterize the residual optical fabrication errors and relate the resulting scattering behavior to the tool and machine parameters in order to evaluate and improve the deterministic microgrinding process. Other desired information derived from the investigation of scattering behavior is the optical fabrication tolerances necessary to satisfy specific image quality requirements. Optical fabrication tolerances are a major cost driver for any precision optical manufacturing technology. The derivation and control of the optical fabrication tolerances necessary for different applications and operating wavelength regimes will play a unique and central role in establishing deterministic microgrinding as a preferred and a cost-effective optical fabrication process. Other well understood optical fabrication processes will also be reviewed and a performance comparison with the conventional grinding and polishing technique will be made to determine any inherent advantages in the optical quality of surfaces produced by other techniques.

  2. The interplay of post-translational modification and gene therapy.

    PubMed

    Osamor, Victor Chukwudi; Chinedu, Shalom N; Azuh, Dominic E; Iweala, Emeka Joshua; Ogunlana, Olubanke Olujoke

    2016-01-01

    Several proteins interact either to activate or repress the expression of other genes during transcription. Based on the impact of these activities, the proteins can be classified into readers, modifier writers, and modifier erasers depending on whether histone marks are read, added, or removed, respectively, from a specific amino acid. Transcription is controlled by dynamic epigenetic marks with serious health implications in certain complex diseases, whose understanding may be useful in gene therapy. This work highlights traditional and current advances in post-translational modifications with relevance to gene therapy delivery. We report that enhanced understanding of epigenetic machinery provides clues to functional implication of certain genes/gene products and may facilitate transition toward revision of our clinical treatment procedure with effective fortification of gene therapy delivery.

  3. Optical system for object detection and delineation in space

    NASA Astrophysics Data System (ADS)

    Handelman, Amir; Shwartz, Shoam; Donitza, Liad; Chaplanov, Loran

    2018-01-01

    Object recognition and delineation is an important task in many environments, such as in crime scenes and operating rooms. Marking evidence or surgical tools and attracting the attention of the surrounding staff to the marked objects can affect people's lives. We present an optical system comprising a camera, computer, and small laser projector that can detect and delineate objects in the environment. To prove the optical system's concept, we show that it can operate in a hypothetical crime scene in which a pistol is present and automatically recognize and segment it by various computer-vision algorithms. Based on such segmentation, the laser projector illuminates the actual boundaries of the pistol and thus allows the persons in the scene to comfortably locate and measure the pistol without holding any intermediator device, such as an augmented reality handheld device, glasses, or screens. Using additional optical devices, such as diffraction grating and a cylinder lens, the pistol size can be estimated. The exact location of the pistol in space remains static, even after its removal. Our optical system can be fixed or dynamically moved, making it suitable for various applications that require marking of objects in space.

  4. Enhanced magneto-optical imaging of internal stresses in the removed surface layer

    NASA Astrophysics Data System (ADS)

    Agalidi, Yuriy; Kozhukhar, Pavlo; Levyi, Sergii; Turbin, Dmitriy

    2015-10-01

    The paper describes a software method of reconstructing the state of the removed surface layer by visualising internal stresses in the underlying layers of the sample. Such a problem typically needs to be solved as part of forensic investigation that aims to reveal original marking of a sample with removed surface layer. For example, one may be interested in serial numbers of weapons or vehicles that had the surface layer of metal removed from the number plate. Experimental results of studying gradient internal stress fields in ferromagnetic sample using the NDI method of magneto-optical imaging (MOI) are presented. Numerical modelling results of internal stresses enclosed in the surface marking region are analysed and compared to the experimental results of magneto-optical imaging (MOI). MOI correction algorithm intended for reconstructing internal stress fields in the removed surface layer by extracting stresses retained by the underlying layers is described. Limiting ratios between parameters of a marking font are defined for the considered correction algorithm. Enhanced recognition properties for hidden stresses left by marking symbols are experimentally verified and confirmed.

  5. How to Get from Cupertino to Boca Raton.

    ERIC Educational Resources Information Center

    Troxel, Duane K.; Chiavacci, Jim

    1985-01-01

    Describes seven methods to transfer data from Apple computer disks to IBM computer disks and vice versa: print out data and retype; use a commercial software package, optical-character reader, homemade cable, or modem to pass or transfer data directly; pay commercial data-transfer service; or store files on mainframe and download. (MBR)

  6. Disposable cartridge biosensor platform for portable diagnostics

    NASA Astrophysics Data System (ADS)

    Yaras, Yusuf S.; Cakmak, Onur; Gunduz, Ali B.; Saglam, Gokhan; Olcer, Selim; Mostafazadeh, Aref; Baris, Ibrahim; Civitci, Fehmi; Yaralioglu, Goksen G.; Urey, Hakan

    2017-03-01

    We developed two types of cantilever-based biosensors for portable diagnostics applications. One sensor is based on MEMS cantilever chip mounted in a microfluidic channel and the other sensor is based on a movable optical fiber placed across a microfluidic channel. Both types of sensors were aimed at direct mechanical measurement of coagulation time in a disposable cartridge using plasma or whole blood samples. There are several similarities and also some important differences between the MEMS based and the optical fiber based solutions. The aim of this paper is to provide a comparison between the two solutions and the results. For both types of sensors, actuation of the cantilever or the moving fiber is achieved using an electro coil and the readout is optical. Since both the actuation and sensing are remote, no electrical connections are required for the cartridge. Therefore it is possible to build low cost disposable cartridges. The reader unit for the cartridge contains light sources, photodetectors, the electro coil, a heater, analog electronics, and a microprocessor. The reader unit has different optical interfaces for the cartridges that have MEMS cantilevers and moving fibers. MEMS based platform has better sensitivity but optomechanical alignment is a challenge and measurements with whole blood were not possible due to high scattering of light by the red blood cells. Fiber sensor based platform has relaxed optomechanical tolerances, ease of manufacturing, and it allows measurements in whole blood. Both sensors were tested using control plasma samples for activated-Partial-Thromboplastin-Time (aPTT) measurements. Control plasma test results matched with the manufacturer's datasheet. Optical fiber based system was tested for aPTT tests with human whole blood samples and the proposed platform provided repeatable test results making the system method of choice for portable diagnostics.

  7. A Pipeline for 3D Digital Optical Phenotyping Plant Root System Architecture

    NASA Astrophysics Data System (ADS)

    Davis, T. W.; Shaw, N. M.; Schneider, D. J.; Shaff, J. E.; Larson, B. G.; Craft, E. J.; Liu, Z.; Kochian, L. V.; Piñeros, M. A.

    2017-12-01

    This work presents a new pipeline for digital optical phenotyping the root system architecture of agricultural crops. The pipeline begins with a 3D root-system imaging apparatus for hydroponically grown crop lines of interest. The apparatus acts as a self-containing dark room, which includes an imaging tank, motorized rotating bearing and digital camera. The pipeline continues with the Plant Root Imaging and Data Acquisition (PRIDA) software, which is responsible for image capturing and storage. Once root images have been captured, image post-processing is performed using the Plant Root Imaging Analysis (PRIA) command-line tool, which extracts root pixels from color images. Following the pre-processing binarization of digital root images, 3D trait characterization is performed using the next-generation RootReader3D software. RootReader3D measures global root system architecture traits, such as total root system volume and length, total number of roots, and maximum rooting depth and width. While designed to work together, the four stages of the phenotyping pipeline are modular and stand-alone, which provides flexibility and adaptability for various research endeavors.

  8. Editorial

    NASA Astrophysics Data System (ADS)

    Gaskill, Jack D.

    1988-02-01

    After a year in which United States presidential candidates, supreme court nominees, and television evangelists offered confession after confession, I have begun to feel that by not confessing something, have not fulfilled my duties as Editor of Optical Engineering. As a result, even if it does rule out any future political aspirations I might have, I have decided that I must confess a shameful deed: I allowed myself to be "bought." That's right! In return for certain favors, I authorized the publication of a paper that otherwise might never have scattered any optical radiation to the eyes of the reader.

  9. Breast screening: the use of consensus opinion for all recalls.

    PubMed

    Matcham, N J; Ridley, N T F; Taylor, S J; Cook, J-L; Scolding, J

    2004-06-01

    The quality of a breast-screening programme is measured not only by it's cancer detection rates (sensitivity), but also by it's recall rates and positive predictive values (specificity). False positive screens, which lead to assessments with benign outcomes, can cause psychological and physical morbidity in previously well women. In 1999 the Wiltshire breast-screening programme adopted a novel recall strategy whereby all films marked for recall are subject to consensus opinion--even women "recalled" by both original readers may be returned to routine screening. Since 1999 our recall rates have fallen from above to below the national averages (prevalent 7.2% and incident 3.0% in 2001/02). Specificity has increased over the same period such that approximately one in seven women assessed will be diagnosed with cancer. The consensus meetings provide a forum for teaching and are very popular with our film readers, who all report reduced levels of stress. Copyright 2003 Elsevier Ltd.

  10. Reading and Hearing The Womans Booke in Early Modern England

    PubMed Central

    Richards, Jennifer

    2015-01-01

    Summary This essay takes seriously Thomas Raynalde’s advice in The Womans Booke that women might read this work aloud. The evidence I use to sketch the scene of reading includes Raynalde’s advice to readers in his long prologue, and also the kind of reading practice that his own writing represents. But I also go outside the text, considering what we know about the experience of listening to a book, and emphasizing the link between this practice and rhetorical education. I also examine the evidence left behind by two male readers: William Ward, who marked his copy of the 1565 edition privately, and Edward Poeton of Petworth, who represented instead a semipublic or shared reading: the evaluation of The Womans Booke and other books of generation by a Midwife and her Deputy in a fictional dialogue “The Midwives Deputie” (ca. 1630s). PMID:26521668

  11. 48 CFR 252.225-7039 - Contractors performing private security functions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., Tagging, Labeling, and Marking of Government-Furnished Property, and physically marked in accordance with... countermeasures (other than the discharge of a weapon, including laser optical distracters, acoustic hailing...

  12. 48 CFR 252.225-7039 - Contractors performing private security functions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., Tagging, Labeling, and Marking of Government-Furnished Property, and physically marked in accordance with... countermeasures (other than the discharge of a weapon, including laser optical distracters, acoustic hailing...

  13. High-throughput and automated diagnosis of antimicrobial resistance using a cost-effective cellphone-based micro-plate reader

    NASA Astrophysics Data System (ADS)

    Feng, Steve; Tseng, Derek; di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-12-01

    Routine antimicrobial susceptibility testing (AST) can prevent deaths due to bacteria and reduce the spread of multi-drug-resistance, but cannot be regularly performed in resource-limited-settings due to technological challenges, high-costs, and lack of trained professionals. We demonstrate an automated and cost-effective cellphone-based 96-well microtiter-plate (MTP) reader, capable of performing AST without the need for trained diagnosticians. Our system includes a 3D-printed smartphone attachment that holds and illuminates the MTP using a light-emitting-diode array. An inexpensive optical fiber-array enables the capture of the transmitted light of each well through the smartphone camera. A custom-designed application sends the captured image to a server to automatically determine well-turbidity, with results returned to the smartphone in ~1 minute. We tested this mobile-reader using MTPs prepared with 17 antibiotics targeting Gram-negative bacteria on clinical isolates of Klebsiella pneumoniae, containing highly-resistant antimicrobial profiles. Using 78 patient isolate test-plates, we demonstrated that our mobile-reader meets the FDA-defined AST criteria, with a well-turbidity detection accuracy of 98.21%, minimum-inhibitory-concentration accuracy of 95.12%, and a drug-susceptibility interpretation accuracy of 99.23%, with no very major errors. This mobile-reader could eliminate the need for trained diagnosticians to perform AST, reduce the cost-barrier for routine testing, and assist in spatio-temporal tracking of bacterial resistance.

  14. Optic disc segmentation: level set methods and blood vessels inpainting

    NASA Astrophysics Data System (ADS)

    Almazroa, A.; Sun, Weiwei; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-03-01

    Segmenting the optic disc (OD) is an important and essential step in creating a frame of reference for diagnosing optic nerve head (ONH) pathology such as glaucoma. Therefore, a reliable OD segmentation technique is necessary for automatic screening of ONH abnormalities. The main contribution of this paper is in presenting a novel OD segmentation algorithm based on applying a level set method on a localized OD image. To prevent the blood vessels from interfering with the level set process, an inpainting technique is applied. The algorithm is evaluated using a new retinal fundus image dataset called RIGA (Retinal Images for Glaucoma Analysis). In the case of low quality images, a double level set is applied in which the first level set is considered to be a localization for the OD. Five hundred and fifty images are used to test the algorithm accuracy as well as its agreement with manual markings by six ophthalmologists. The accuracy of the algorithm in marking the optic disc area and centroid is 83.9%, and the best agreement is observed between the results of the algorithm and manual markings in 379 images.

  15. A portable optical reader and wall projector towards enumeration of bio-conjugated beads or cells

    PubMed Central

    McArdle, Niamh A.; Kendlin, Jane L.; O’Connell, Triona M.; Ducrée, Jens

    2017-01-01

    Measurement of the height of a packed column of cells or beads, which can be direclty related to the number of cells or beads present in a chamber, is an important step in a number of diagnostic assays. For example, haematocrit measurements may rapidly identify anemia or polycthemia. Recently, user-friendly and cost-efficient Lab-on-a-Chip devices have been developed towards isolating and counting cell sub-populations for diagnostic purposes. In this work, we present a low-cost optical module for estimating the filling level of packed magnetic beads within a Lab-on-a-Chip device. The module is compatible with a previously introduced, disposable microfluidic chip for rapid determination of CD4+ cell counts. The device is a simple optical microscope module is manufactured by 3D printing. An objective lens directly interrogates the height of packed beads which are efficiently isolated on the finger-actuated chip. Optionally, an inexpensive, battery-powered Light Emitting Diode may project a shadow of the microfluidic chip at approximately 50-fold magnification onto a nearby surface. The reader is calibrated with the filling levels of known concentrations of paramagnetic beads within the finger actuated chip. Results in direct and projector mode are compared to measurements from a conventional, inverted white-light microscope. All three read-out methods indicate a maximum variation of 6.5% between methods. PMID:29267367

  16. Shaping epigenetic memory via genomic bookmarking

    PubMed Central

    Chiang, Michael; Colì, Davide; Papantonis, Argyris; Orlandini, Enzo; Cook, Peter R

    2018-01-01

    Abstract Reconciling the stability of epigenetic patterns with the rapid turnover of histone modifications and their adaptability to external stimuli is an outstanding challenge. Here, we propose a new biophysical mechanism that can establish and maintain robust yet plastic epigenetic domains via genomic bookmarking (GBM). We model chromatin as a recolourable polymer whose segments bear non-permanent histone marks (or colours) which can be modified by ‘writer’ proteins. The three-dimensional chromatin organisation is mediated by protein bridges, or ‘readers’, such as Polycomb Repressive Complexes and Transcription Factors. The coupling between readers and writers drives spreading of biochemical marks and sustains the memory of local chromatin states across replication and mitosis. In contrast, GBM-targeted perturbations destabilise the epigenetic patterns. Strikingly, we demonstrate that GBM alone can explain the full distribution of Polycomb marks in a whole Drosophila chromosome. We finally suggest that our model provides a starting point for an understanding of the biophysics of cellular differentiation and reprogramming. PMID:29190361

  17. Differences between genders in colorectal morphology on CT colonography using a quantitative approach: a pilot study.

    PubMed

    Weber, Charles N; Poff, Jason A; Lev-Toaff, Anna S; Levine, Marc S; Zafar, Hanna M

    To explore quantitative differences between genders in morphologic colonic metrics and determine metric reproducibility. Quantitative colonic metrics from 20 male and 20 female CTC datasets were evaluated twice by two readers; all exams were performed after incomplete optical colonoscopy. Intra-/inter-reader reliability was measured with intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). Women had overall decreased colonic volume, increased tortuosity and compactness and lower sigmoid apex height on CTC compared to men (p<0.0001,all). Quantitative measurements in colonic metrics were highly reproducible (ICC=0.9989 and 0.9970; CCC=0.9945). Quantitative morphologic differences between genders can be reproducibility measured. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Response to the comment on ``Design and analysis of wide-field-of-view polarization imaging spectrometer''

    NASA Astrophysics Data System (ADS)

    Zhang, Chunmin; Mu, Tingkui

    2011-04-01

    Herein, we sincerely make an apology to readers for our misguidance. We have made a mistake on the analysis of the optical path difference produced by the Savart polariscope which resulted in the improper design of a wide-field-of-view Savart polariscope. The correct statements are presented.

  19. Using Technology To Combat Truancy. Number 10 in a Series of CTC Trust Publications.

    ERIC Educational Resources Information Center

    Haigh, Gerald

    The 14 City Technology Colleges (CTCs) opened so far in Great Britain are achieving an average attendance rate of between 90 percent and 97 percent. This high level of attendance has been assisted by the use of electronic registration (role taking) devices, including smart cards, portable computers, and optical readers. This report compares…

  20. An active UHF RFID localization system for fawn saving

    NASA Astrophysics Data System (ADS)

    Eberhardt, M.; Lehner, M.; Ascher, A.; Allwang, M.; Biebl, E. M.

    2015-11-01

    We present a localization concept for active UHF RFID transponders which enables mowing machine drivers to detect and localize marked fawns. The whole system design and experimental results with transponders located near the ground in random orientations in a meadow area are shown. The communication flow between reader and transponders is realized as a dynamic master-slave concept. Multiple marked fawns will be localized by processing detected transponders sequentially. With an eight-channel-receiver with integrated calibration method one can estimate the direction-of-arrival by measuring the phases of the transponder signals up to a range of 50 m in all directions. For further troubleshooting array manifolds have been measured. An additional hand-held receiver with a two-channel receiver allows a guided approaching search without endangering the fawn by the mowing machine.

  1. Vacuum Arc Vapor Deposition Method and Apparatus for Applying Identification Symbols to Substrates

    NASA Technical Reports Server (NTRS)

    Schramm, Harry F. (Inventor); Roxby, Donald L. (Inventor); Weeks, Jack L. (Inventor)

    2002-01-01

    An apparatus for applying permanent markings onto products using a Vacuum Arc Vapor Deposition (VAVD) marker by accelerating atoms or molecules from a vaporization source onto a substrate to form human and/or machine-readable part identification marking that can be detected optically or via a sensing device like x-ray, thermal imaging, ultrasound, magneto-optic, micro-power impulse radar, capacitance, or other similar sensing means. The apparatus includes a housing with a nozzle having a marking end. A chamber having an electrode, a vacuum port and a charge is located within the housing. The charge is activated by the electrode in a vacuum environment and deposited onto a substrate at the marking end of the nozzle. The apparatus may be a hand-held device or be disconnected from the handle and mounted to a robot or fixed station.

  2. Comparison of the three optical platforms for measurement of cellular respiration.

    PubMed

    Kondrashina, Alina V; Ogurtsov, Vladimir I; Papkovsky, Dmitri B

    2015-01-01

    We compared three optical platforms for measurement of cellular respiration: absolute oxygen consumption rates (OCRs) in hermetically sealed microcuvettes, relative OCRs measured in a 96-well plate with oil seal, and steady-state oxygenation of cells in an open 96-well plate. Using mouse embryonic fibroblasts cell line, the phosphorescent intracellular O2 probe MitoXpress-Intra, and time-resolved fluorescence reader, we determined algorithms for conversion of relative OCRs and cell oxygenation into absolute OCRs, thereby allowing simple high-throughput measurement of absolute OCR values. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Optically stimulated luminescence in Cu+ doped lithium orthophosphate

    NASA Astrophysics Data System (ADS)

    Barve, R. A.; Patil, R. R.; Moharil, S. V.; Bhatt, B. C.; Kulkarni, M. S.

    2015-02-01

    Optically stimulated luminescence (OSL) in Cu+ doped Li3PO4 synthesized by co-precipitation technique using different phosphorus precursors was studied. Changes in the luminescent properties were observed with change in the phosphorus precursors. All the synthesized phosphors showed intense fading but the OSL sensitivity was comparable to that of the commercially available Al2O3:C (Landauer Inc.). In general, BSL (blue stimulated luminescence) decay was very fast but the GSL (green stimulated luminescence) decay was comparable to that of Al2O3:C phosphor. Phosphors with fast decay, good sensitivity and intense fading are suitable for real-time dosimetry. Therefore, Cu-doped Li3PO4 could be developed for real-time dosimetry using a fiber optic based OSL reader system.

  4. Spinning angle optical calibration apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beer, S.K.; Pratt, H.R.

    1991-02-26

    This patent describes an optical calibration apparatus provided for calibrating and reproducing spinning angles in cross-polarization, nuclear magnetic resonance spectroscopy. An illuminated magnifying apparatus enables optical setting an accurate reproducing of spinning magic angles in cross-polarization, nuclear magnetic resonance spectroscopy experiments. A reference mark scribed on an edge of a spinning angle test sample holder is illuminated by a light source and viewed through a magnifying scope. When the magic angle of a sample material used as a standard is attained by varying the angular position of the sample holder, the coordinate position of the reference mark relative to amore » graduation or graduations on a reticle in the magnifying scope is noted.« less

  5. Converting Optically Scanned Regular or Irregular Tables to a Standardised Markup Format to Be Accessible to Vision-Impaired

    ERIC Educational Resources Information Center

    Nazemi, Azadeh; Murray, Iain; Fernaando, Chandrika; McMeekin, David A.

    2016-01-01

    Documents use tables to communicate multidimensional information clearly, summarise and present data in an easy-to-interpret way. Tabular information in scanned PDF due to its nature without further processing is not accessible for vision-impaired people who use assistive technology such as screen readers. The lack of access to table contents…

  6. Optical Communications: A Compendium of Signal Formats, Receiver Architectures, Analysis Mathematics, and Performance Characteristics

    DTIC Science & Technology

    2005-09-09

    the properties that Ps 2 = (2N,) M = 2 (147) Ps4 = 0-(l-Ps 2 ) 2 M =4 . (148) Interestingly, the bit-error probability from Gray-coded 4PSK is the...comparisons will motivate the reader to invent efficient systems that can achieve the theoretical possibilities. 61 REFERENCES [1] Ban, M., Kurokawa, K

  7. Role of tool marks inside spherical mitigation pit fabricated by micro-milling on repairing quality of damaged KH2PO4 crystal

    PubMed Central

    Chen, Ming-Jun; Cheng, Jian; Yuan, Xiao-Dong; Liao, Wei; Wang, Hai-Jun; Wang, Jing-He; Xiao, Yong; Li, Ming-Quan

    2015-01-01

    Repairing initial slight damage site into stable structures by engineering techniques is the leading strategy to mitigate the damage growth on large-size components used in laser-driven fusion facilities. For KH2PO4 crystals, serving as frequency converter and optoelectronic switch-Pockels cell, micro-milling has been proven the most promising method to fabricate these stable structures. However, tool marks inside repairing pit would be unavoidably introduced due to the wearing of milling cutter in actual repairing process. Here we quantitatively investigate the effect of tool marks on repairing quality of damaged crystal components by simulating its induced light intensification and testing the laser-induced damage threshold. We found that due to the formation of focusing hot spots and interference ripples, the light intensity is strongly enhanced with the presence of tool marks, especially for those on rear surfaces. Besides, the negative effect of tool marks is mark density dependent and multiple tool marks would aggravate the light intensification. Laser damage tests verified the role of tool marks as weak points, reducing the repairing quality. This work offers new criterion to comprehensively evaluate the quality of repaired optical surfaces to alleviate the bottleneck issue of low laser damage threshold for optical components in laser-driven fusion facilities. PMID:26399624

  8. Optical Encoding Technology for Viral Screening Panels Final Report CRADA No TC02132.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenhoff, R.; Haushalter, R.

    This was a collaborative effort between Lawrence Livermore National Security, LLC, Lawrence Livermore National Laboratory (LLNL) and Parallel Synthesis Technologies, Inc. (PSTI), to develop Optical Encoding Technology for Viral Screening Panels. The goal for this effort was to prepare a portable bead reader system that would enable the development of viral and bacterial screening panels which could be used for the detection of any desired set of bacteria or viruses in any location. The main objective was to determine if the combination of a bead-based, PCR suspension array technology, formulated from Parallume encoded beads and PSTI’s multiplex assay reader systemmore » (MARS), could provide advantages in terms of the number of simultaneously measured samples, portability, ruggedness, ease of use, accuracy, precision or cost as compared to the Luminexbased system developed at LLNL. The project underwent several no cost extensions however the overall goal of demonstrating the utility of this new system was achieved. As a result of the project a significant change to the type of bead PSTI used for the suspension system was implemented allowing better performance than the commercial Luminex system.« less

  9. Ultra Compact Optical Pickup with Integrated Optical System

    NASA Astrophysics Data System (ADS)

    Nakata, Hideki; Nagata, Takayuki; Tomita, Hironori

    2006-08-01

    Smaller and thinner optical pickups are needed for portable audio-visual (AV) products and notebook personal computers (PCs). We have newly developed an ultra compact recordable optical pickup for Mini Disc (MD) that measures less than 4 mm from the disc surface to the bottom of the optical pickup, making the optical system markedly compact. We have integrated all the optical components into an objective lens actuator moving unit, while fully satisfying recording and playback performance requirements. In this paper, we propose an ultra compact optical pickup applicable to portable MD recorders.

  10. H4K20me0 marks post-replicative chromatin and recruits the TONSL₋MMS22L DNA repair complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saredi, Giulia; Huang, Hongda; Hammond, Colin M.

    Here, we report that after DNA replication, chromosomal processes including DNA repair and transcription take place in the context of sister chromatids. While cell cycle regulation can guide these processes globally, mechanisms to distinguish pre- and post-replicative states locally remain unknown. In this paper we reveal that new histones incorporated during DNA replication provide a signature of post-replicative chromatin, read by the human TONSL–MMS22L 1, 2, 3, 4 homologous recombination complex. We identify the TONSL ankyrin repeat domain (ARD) as a reader of histone H4 tails unmethylated at K20 (H4K20me0), which are specific to new histones incorporated during DNA replicationmore » and mark post-replicative chromatin until the G2/M phase of the cell cycle. Accordingly, TONSL–MMS22L binds new histones H3–H4 both before and after incorporation into nucleosomes, remaining on replicated chromatin until late G2/M. H4K20me0 recognition is required for TONSL–MMS22L binding to chromatin and accumulation at challenged replication forks and DNA lesions. Consequently, TONSL ARD mutants are toxic, compromising genome stability, cell viability and resistance to replication stress. Finally, together, these data reveal a histone-reader-based mechanism for recognizing the post-replicative state, offering a new angle to understand DNA repair with the potential for targeted cancer therapy.« less

  11. Image-guided biopsy in the esophagus through comprehensive optical frequency domain imaging and laser marking: a study in living swine.

    PubMed

    Suter, Melissa J; Jillella, Priyanka A; Vakoc, Benjamin J; Halpern, Elkan F; Mino-Kenudson, Mari; Lauwers, Gregory Y; Bouma, Brett E; Nishioka, Norman S; Tearney, Guillermo J

    2010-02-01

    Random biopsy esophageal surveillance can be subject to sampling errors, resulting in diagnostic uncertainty. Optical frequency domain imaging (OFDI) is a high-speed, 3-dimensional endoscopic microscopy technique. When deployed through a balloon-centering catheter, OFDI can automatically image the entire distal esophagus (6.0 cm length) in approximately 2 minutes. To test a new platform for guided biopsy that allows the operator to select target regions of interest on an OFDI dataset, and then use a laser to mark the esophagus at corresponding locations. The specific goals include determining the optimal laser parameters, testing the accuracy of the laser marking process, evaluating the endoscopic visibility of the laser marks, and assessing the amount of mucosal damage produced by the laser. Experimental study conducted in 5 swine in vivo. Massachusetts General Hospital. Success rate, including endoscopic visibility of laser marks and accuracy of the laser marking process for selected target sites, and extent of the thermal damage caused by the laser marks. All of the laser-induced marks were visible by endoscopy. Target locations were correctly marked with a success rate of 97.07% (95% confidence interval, 89.8%-99.7%). Thermal damage was limited to the superficial layers of the mucosa and was observed to partially heal within 2 days. An animal study with artificially placed targets to simulate pathology. The study demonstrates that laser marking of esophageal sites identified in comprehensive OFDI datasets is feasible and can be performed with sufficient accuracy, precision, and visibility to guide biopsy in vivo.

  12. Smooth Optical Self-similar Emission of Gamma-Ray Bursts

    NASA Astrophysics Data System (ADS)

    Lipunov, Vladimir; Simakov, Sergey; Gorbovskoy, Evgeny; Vlasenko, Daniil

    2017-08-01

    We offer a new type of calibration for gamma-ray bursts (GRB), in which some class of GRB can be marked and share a common behavior. We name this behavior Smooth Optical Self-similar Emission (SOS-similar Emission) and identify this subclasses of GRBs with optical light curves described by a universal scaling function.

  13. DOC II 32-bit digital optical computer: optoelectronic hardware and software

    NASA Astrophysics Data System (ADS)

    Stone, Richard V.; Zeise, Frederick F.; Guilfoyle, Peter S.

    1991-12-01

    This paper describes current electronic hardware subsystems and software code which support OptiComp's 32-bit general purpose digital optical computer (DOC II). The reader is referred to earlier papers presented in this section for a thorough discussion of theory and application regarding DOC II. The primary optoelectronic subsystems include the drive electronics for the multichannel acousto-optic modulators, the avalanche photodiode amplifier, as well as threshold circuitry, and the memory subsystems. This device utilizes a single optical Boolean vector matrix multiplier and its VME based host controller interface in performing various higher level primitives. OptiComp Corporation wishes to acknowledge the financial support of the Office of Naval Research, the National Aeronautics and Space Administration, the Rome Air Development Center, and the Strategic Defense Initiative Office for the funding of this program under contracts N00014-87-C-0077, N00014-89-C-0266 and N00014-89-C- 0225.

  14. Fiber Optic Feed

    DTIC Science & Technology

    1990-11-06

    Naval Research Laboratory IIK Washington, DC,20375 5000 NRL Memorandum Report 6741 0 N Fiber Optic Feed DENZIL STILWELL, MARK PARENT AND LEw GOLDBERG...SUBTITLE S. FUNDING NUMBERS Fiber Optic Feed 53-0611-A0 6. AUTHOR(S) P. D. Stilwell, M. G. Parent, L. Goldberg 7. PERFORMING ORGANIZATION NAME(S) AND...DISTRIBUTION CODE Approved for public release; distribution unlimited. 13. ABSTRACT (Maximum 200 words) This report details a Fiber Optic Feeding

  15. Base-Level Management of Laser Radiation Protection Program

    DTIC Science & Technology

    1992-02-01

    safety eyewear . special considerations for medical lasers and optical fibers, and summary evaluations of common Air Force laser systems... optical density of 2. Laser safety eyewear should have the optical density clearly marked for ail wavelengths for which the eyewear provides protection. c...density of protective eyewear . The optical density required for laser safety eyewear is dependent on the irradiance or radiant exposure-of the

  16. 20 years of graduate optics education at the University of New Mexico

    NASA Astrophysics Data System (ADS)

    Osiński, Marek; Jungling, Kenneth C.; Sheik-Bahae, Mansoor; Prasad, Sudhakar; McIver, John K.; Guenther, Arthur H.

    2003-10-01

    The year 2003 marks the 20th anniversary of introducing interdisciplinary graduate optics education at the University of New Mexico. The Ph.D. program in Optical Sciences has produced over 75 graduates. A new M.S. program in Optical Science and Engineering, introduced in Fall 2002, is rapidly gaining popularity. This paper reviews both programs, focusing on their unique features.

  17. Embodied Cognition and Empathy in Miguel de Cervantes's El celoso extremeño.

    PubMed

    Carrera, Elena

    2014-03-01

    This article examines the portrayal of cognitive experience in the published version of Miguel de Cervantes's short story El celoso extremeño (1613), drawing both on recent studies of empathy and current debates about the inseparability of cognition and emotion. It considers how cognitive experience is marked by particular bodily sensations and shaped by internal representations (i.e., mental images) that are closely tied to emotions such as fear, jealousy, joy, and sorrow. Paying particular attention to the ways in which the narrative underscores the characters' limited sensory experiences and their defective understanding of each other's positions, the article argues that this provides the reader with the opportunity to simulate mentally his or her own challenging situations, faulty judgments, and injudicious actions. While being invited to use his or her imagination and judgment to enjoy being placed in a position of greater power and knowledge than the characters, Cervantes's reader is also encouraged to consider the possibility of not knowing and to accept the limits of empathy.

  18. Rethinking m6A Readers, Writers, and Erasers

    PubMed Central

    Meyer, Kate D.; Jaffrey, Samie R.

    2018-01-01

    In recent years, m6A has emerged as an abundant and dynamically regulated modification throughout the transcriptome. Recent technological advances have enabled the transcriptome-wide identification of m6A residues, which in turn has provided important insights into the biology and regulation of this pervasive regulatory mark. Also central to our current understanding of m6A are the discovery and characterization of m6A readers, writers, and erasers. Over the last few years, studies into the function of these proteins have led to important discoveries about the regulation and function of m6A. However, during this time our understanding of these proteins has also evolved considerably, sometimes leading to the reversal of early conceptions regarding the reading, writing and erasing of m6A. In this review, we summarize recent advances in m6A research, and we highlight how these new findings have reshaped our understanding of how m6A is regulated in the transcriptome. PMID:28759256

  19. Castles in the Air: The Einstein-De Sitter Debate, 1916-1918

    NASA Astrophysics Data System (ADS)

    Midwinter, Charles; Janssen, Michel

    2011-03-01

    The Einstein De Sitter debate marked the birth of modern cosmology and the infamous cosmological constant. For Einstein, the controversy was essentially a philosophical one. Einstein's insistence on a static Universe and Mach's Principle guided him in the construction of his own cosmological model, and compelled him to criticize De Sitter's. For De Sitter, the debate began as idle conjecture. Before long, however, he began to wonder if the "spacious castles" he and Einstein had constructed might actually represent physical reality. We plan to write a volume that reproduces the documents relevant to the debate. Our commentary will retrace and explain the arguments of the historical players, complete with calculations. For the first time readers will be able to follow the arguments of Einstein and De Sitter in a detailed exploration of the first two relativistic cosmological models. Readers will see how Einstein's flawed criticisms of De Sitter were supported by Herman Weyl, and finally how Felix Klein settled the whole matter with a coordinate transformation.

  20. FILM FORMAT AND FIDUCIAL MARKS OF THE 20$sub 4$ BUBBLE CHAMBER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, E.L.

    1962-12-31

    A description is given of the 20-in. bubble chamber film format. The film format consists of: chamber image; Arabic picture number; binary data box; Arabic view number; and the Hough-Powell road fiducial marks. The fiducial marks and their relation to the chamber optical constants are discussed. The constants are based on the standard measuring fiducials a and d. (P.C.H.)

  1. Active control of residual tool marks for freeform optics functionalization by novel biaxial servo assisted fly cutting.

    PubMed

    Zhu, Zhiwei; To, Suet; Zhang, Shaojian

    2015-09-01

    The inherent residual tool marks (RTM) with particular patterns highly affect optical functions of the generated freeform optics in fast tool servo or slow tool servo (FTS/STS) diamond turning. In the present study, a novel biaxial servo assisted fly cutting (BSFC) method is developed for flexible control of the RTM to be a functional micro/nanotexture in freeform optics generation, which is generally hard to achieve in FTS/STS diamond turning. In the BSFC system, biaxial servo motions along the z-axis and side-feeding directions are mainly adopted for primary surface generation and RTM control, respectively. Active control of the RTM from the two aspects, namely, undesired effect elimination or effective functionalization, are experimentally demonstrated by fabricating a typical F-theta freeform surface with scattering homogenization and two functional microstructures with imposition of secondary phase gratings integrating both reflective and diffractive functions.

  2. Ventana{trade mark, serif} power train features and performance

    NASA Astrophysics Data System (ADS)

    Mohedano, R.; Benitez, P.; Zamora, P.; Miñano, J. C.; Mendes, J.; Cvetkovic, A.; Vilaplana, J.; Hernandez, M.; Chaves, J.; Biot, G.

    2013-09-01

    Most CPV systems are based on Fresnel lenses. Among these, LPI-patented Fresnel-Köhler (FK) concentrator outstands owing to performance and practical reasons. The Ventana{trade mark, serif} power train is the first off-the-shelf commercial product based on the FK and comprises both the primary (POE) lenses (a 36-units 1×1 m2 acrylic panel) and glass (or silica glass) secondary optics (SOE). This high concentration optical train (Cg=1,024×, ˜250mm optical depth) fits with 5×5 mm2 (at least) solar cells. The optical train is the fruit of a 1-year development that has included design, modeling, prototyping and characterization, and through the process we had the opportunity to find out how well the actual performance correlates with models, but also learned practical aspects of a CPV system of this kind, some of which have very positive impact on system performance and reliability.

  3. Direct Age Determination of a Subtropical Freshwater Crayfish (Redclaw, Cherax quadricarinatus) Using Ossicular Growth Marks

    PubMed Central

    Leland, Jesse C.; Bucher, Daniel J.; Coughran, Jason

    2015-01-01

    Recent studies have reported that crustacean age determination is possible. We applied a direct ageing method (i.e. transverse cross sectioning of gastric ossicles) to a subtropical freshwater crayfish (Cherax quadricarinatus) sourced from an aquaculture population. Growth mark periodicity and the potential for chronological depositions were investigated by staining C. quadricarinatus with calcein and examining their ossicles a year later. Pterocardiac ossicles were superior to other ageing structures (i.e. other ossicles and eyestalks) and produced repeatable between-reader counts (87% were corroborated and 13% varied by ±1). C. quadricarinatus size-at-age data (for an aquaculture population) was described by a von Bertalanffy growth equation (L ∞ = 32 mm occipital carapace length; K = 0.64; t 0 = –0.18; R2 = 0.81). Ossicular growth marks did not correspond to moult history. The calcein stain was retained over an annual cycle comprising multiple moults, demonstrating that pterocardiac ossicles retain chronological information. The maximum age (3+) corroborated other indirectly-obtained longevity estimates for C. quadricarinatus. Multiple lines of evidence indicate that the growth marks in C. quadricarinatus ossicles are probably deposited annually during winter. The ability to extract age information from subtropical decapods provides substantial opportunities for advancing fisheries and conservation research globally, but further research is needed to provide a definitive validation and elucidate the mechanism governing the accrual of ossicular growth marks. PMID:26309228

  4. Effects of inorganic ions on leachability of wood preserving N'N-hydroxynapthalimide (NHA).

    Treesearch

    S. Nami Kartal; Ben F. Dorau; Stan T. Lebow; Frederick III Green

    2004-01-01

    Southern yellow pine sapwood stakes and blocks were treated with the sodium salt of the calcium-precipitating compound N’N-hydroxynapthalimide (NHA) and leach tested for 2 weeks using the American Wood-Preservers’ Association (AWPA) standard. Leacheates were measured for NHA using a microplate optical density ultraviolet reader, and leach rates were estimated for tap...

  5. Microscopy and Image Analysis.

    PubMed

    McNamara, George; Difilippantonio, Michael; Ried, Thomas; Bieber, Frederick R

    2017-07-11

    This unit provides an overview of light microscopy, including objectives, light sources, filters, film, and color photography for fluorescence microscopy and fluorescence in situ hybridization (FISH). We believe there are excellent opportunities for cytogeneticists, pathologists, and other biomedical readers, to take advantage of specimen optical clearing techniques and expansion microscopy-we briefly point to these new opportunities. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  6. Protection of data carriers using secure optical codes

    NASA Astrophysics Data System (ADS)

    Peters, John A.; Schilling, Andreas; Staub, René; Tompkin, Wayne R.

    2006-02-01

    Smartcard technologies, combined with biometric-enabled access control systems, are required for many high-security government ID card programs. However, recent field trials with some of the most secure biometric systems have indicated that smartcards are still vulnerable to well equipped and highly motivated counterfeiters. In this paper, we present the Kinegram Secure Memory Technology which not only provides a first-level visual verification procedure, but also reinforces the existing chip-based security measures. This security concept involves the use of securely-coded data (stored in an optically variable device) which communicates with the encoded hashed information stored in the chip memory via a smartcard reader device.

  7. An integrated skin marking tool for use with optical coherence tomography (OCT)

    NASA Astrophysics Data System (ADS)

    Patalay, Rakesh; Craythorne, Emma; Mallipeddi, Raj; Coleman, Andrew

    2017-02-01

    Optical coherence tomography (OCT) has been shown to provide clinically valuable images that can aid in the assessment of the pre-surgical margin in basal cell carcinoma (BCC). The accuracy and speed with which these images can be used to help delineate margins in the clinic are currently constrained by the need to suspend imaging whilst a pen is used to mark the skin. This constraint has been circumvented here by the design of a trigger-activated ink-loaded nib integrated with the OCT probe. The adapted OCT probe enables a mark to be placed on the skin precisely where a region of interest can be seen in the OCT images, accurately and reproducibly. The adapted probe is described and a comparison of its performance and early experience of its clinical use are reported here. Initial results indicate that the integrated skin marking probe makes margin delineation under OCT image-guidance faster, more accurate and more clinically acceptable.

  8. Ametropia, retinal anatomy, and OCT abnormality patterns in glaucoma. 2. Impacts of optic nerve head parameters

    NASA Astrophysics Data System (ADS)

    Baniasadi, Neda; Wang, Mengyu; Wang, Hui; Jin, Qingying; Elze, Tobias

    2017-12-01

    Clinicians use retinal nerve fiber layer thickness (RNFLT) measured by optical coherence tomography (OCT) as an adjunct to glaucoma diagnosis. Ametropia is accompanied by changes to the optic nerve head (ONH), which may affect how OCT machines mark RNFLT measurements as abnormal. These changes in abnormality patterns may bias glaucoma diagnosis. Here, we investigate the relationship between OCT abnormality patterns and the following ONH-related and ametropia-associated parameters on 421 eyes of glaucoma patients: optic disc tilt and torsion, central retinal vessel trunk location (CRVTL), and nasal and temporal retinal curvature adjacent to ONH, quantified as nasal/temporal slopes of the inner limiting membrane. We applied multivariate logistic regression with abnormality marks as regressands to 40,401 locations of the peripapillary region and generated spatial maps of locations of false positive/negative abnormality marks independent of glaucoma severity. Effects of torsion and temporal slope were negligible. The effect of tilt could be explained by covariation with ametropia. For CRVTL/nasal slope, abnormality pattern shifts at 7.2%/23.5% of the peripapillary region were detected, respectively, independent of glaucoma severity and ametropia. Therefore, CRVTL and nasal curvature should be included in OCT RNFLT norms. Our spatial location maps may aid clinicians to improve diagnostic accuracy.

  9. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging.

    PubMed

    Sogani, Julie; Morris, Elizabeth A; Kaplan, Jennifer B; D'Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S; Jochelson, Maxine S

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA, 2016.

  10. Laser Scanning Reader For Automated Data Entry Operations

    NASA Astrophysics Data System (ADS)

    Cheng, Charles C. K.

    1980-02-01

    The use of the Universal Product Code (UPC) in conjunction with the laser-scanner-equipped electronic checkout system has made it technologically possible for supermarket stores to operate more efficiently and accurately. At present, more than 90% of the packages in grocery stores have been marked by the manufacturer with laser-scannable UPC symbols and the installation of laser scanning systems is expected to expand into all major chain stores. Areas to be discussed are: system design features, laser-scanning pattern generation, signal-processing logical considerations, UPC characteristics and encodation.

  11. Image-Guided Biopsy in the Esophagus through Comprehensive Optical Frequency Domain Imaging and Laser Marking: A Study in Living Swine

    PubMed Central

    Suter, Melissa J.; Jillella, Priyanka A.; Vakoc, Benjamin J.; Halpern, Elkan F.; Mino-Kenudson, Mari; Lauwers, Gregory Y.; Bouma, Brett E.; Nishioka, Norman S.; Tearney, Guillermo J.

    2010-01-01

    Background Random biopsy esophageal surveillance can be subject to sampling errors, resulting in diagnostic uncertainty. Optical frequency domain imaging (OFDI) is a high-speed, three-dimensional endoscopic microscopy technique. When deployed through a balloon-centering catheter, OFDI can automatically image the entire distal esophagus (6.0 cm length) in approximately 2 minutes. Objective To test a new platform for guided biopsy that allows the operator to select target regions of interest on an OFDI dataset, and then use a laser to mark the esophagus at corresponding locations. The specific goals include determining the optimal laser parameters, testing the accuracy of the laser marking process, evaluating the endoscopic visibility of the laser marks, and assessing the amount of mucosal damage produced by the laser. Design Experimental study conducted in five swine in vivo. Setting Massachusetts General Hospital. Main Outcome Measurements Success rate, including endoscopic visibility of laser marks and accuracy of the laser marking process for selected target sites, and extent of the thermal damage caused by the laser marks. Results All of the laser-induced marks were visible by endoscopy. Target locations were correctly marked with a success rate of 97.07% (95% CI, 89.8%-99.7%). Thermal damage was limited to the superficial layers of the mucosa and was observed to partially heal within 2 days. Limitations An animal study with artificially placed targets to simulate pathology. Conclusions The study demonstrates that laser marking of esophageal sites identified in comprehensive OFDI datasets is feasible and can be performed with sufficient accuracy, precision, and visibility to guide biopsy in vivo. PMID:19879573

  12. Application of a liquid crystal spatial light modulator to laser marking.

    PubMed

    Parry, Jonathan P; Beck, Rainer J; Shephard, Jonathan D; Hand, Duncan P

    2011-04-20

    Laser marking is demonstrated using a nanosecond (ns) pulse duration laser in combination with a liquid crystal spatial light modulator to generate two-dimensional patterns directly onto thin films and bulk metal surfaces. Previous demonstrations of laser marking with such devices have been limited to low average power lasers. Application in the ns regime enables more complex, larger scale marks to be generated with more widely available and industrially proven laser systems. The dynamic nature of the device is utilized to improve mark quality by reducing the impact of the inherently speckled intensity distribution across the generated image and reduce thermal effects in the marked surface. © 2011 Optical Society of America

  13. Readout signals calculated for near-field optical pickups with land and groove recording.

    PubMed

    Saito, K; Kishima, K; Ichimura, I

    2000-08-10

    Optical disk readout signals with a solid immersion lens (SIL) and the land-groove recording technique are calculated by use of a simplified vector-diffraction theory. In this method the full vector-diffraction theory is applied to calculate the diffracted light from the initial state of the disk, and the light scattered from the recorded marks is regarded as a perturbation. Using this method, we confirmed that the land-groove recording technique is effective as a means of cross-talk reduction even when the numerical aperture is more than 1. However, the top surface of the disk under the SIL must be flat, or the readout signal from marks recorded on a groove decays when the optical depth of the groove is greater than lambda/8.

  14. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries.

    PubMed

    Pilavaki, Evdokia; Demosthenous, Andreas

    2017-11-20

    Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.

  15. Optical and physical requirements for fluid particles marking trailing vortices from aircraft

    NASA Technical Reports Server (NTRS)

    Back, L. H.

    1976-01-01

    A theoretical study of the optical and physical requirements of marking trailing vortices that emanate from aircraft wings was carried out by considering particulate light-scattering properties, ability of particles to follow trailing vortices, and survival time of particles to vortex dissipation. Liquid droplets undergoing evaporation and molecular dispersion were investigated. Droplets should have lifetimes of about 300 sec. Droplet size should be about 1 micron to maximize light scattering with the minimum mass of liquid required. Droplets of this small size would spiral outward very slowly and essentially remain in the vortex cores. Nontoxic hygroscopic liquids, having an affinity for moisture in the air, have been identified. These liquids have relatively low vapor pressures of order 10 to the -5 mm Hg that would insure droplet persistence long enough to mark trailing vortices.

  16. Initial Evaluations of Mainstream Personality Tests for Use with Visually Impaired Adults in Vocational Assessment and Guidance.

    ERIC Educational Resources Information Center

    Reid, Juliet

    2000-01-01

    This article reviews the Eysenck Personality Questionnaire-Revised (EPQ-R adult and EPQ-R short form), the 16PF5, and the Myers-Briggs Type Indicator for use with adults with visual impairments. Results found only the EPQ-R short form can be used by participants using low vision aids, closed-circuit television, or an optical character reader.…

  17. Application of Optical Disc Databases and Related Technology to Public Access Settings

    DTIC Science & Technology

    1992-03-01

    users to download and retain data. A Video Graphics Adapter (VGA) monitor was included. No printer was provided. 2. CD-ROM Product Computer Select, a...download facilities, without printer support, satisfy user needs? 38 A secondary, but significant, objective was avoidance of unnecessary Reader...design of User Log sheets and mitigated against attachment of a printer to the workstation. F. DATA COLLECTION This section describes the methodology

  18. Optically stimulated luminescence (OSL) dosimetry in medicine.

    PubMed

    Yukihara, E G; McKeever, S W S

    2008-10-21

    This paper reviews fundamental and practical aspects of optically stimulated luminescence (OSL) dosimetry pertaining to applications in medicine, having particularly in mind new researchers and medical physicists interested in gaining familiarity with the field. A basic phenomenological model for OSL is presented and the key processes affecting the outcome of an OSL measurement are discussed. Practical aspects discussed include stimulation modalities (continuous-wave OSL, pulsed OSL and linear modulation OSL), basic experimental setup, available OSL readers, optical fiber systems and basic properties of available OSL dosimeters. Finally, results from the recent literature on applications of OSL in radiotherapy, radiodiagnostics and heavy charged particle dosimetry are discussed in light of the theoretical and practical framework presented in this review. Open questions and future challenges in OSL dosimetry are highlighted as a guide to the research needed to further advance the field.

  19. Fabrication of long linear arrays of plastic optical fibers with squared ends for the use of code mark printing lithography

    NASA Astrophysics Data System (ADS)

    Horiuchi, Toshiyuki; Watanabe, Jun; Suzuki, Yuta; Iwasaki, Jun-ya

    2017-05-01

    Two dimensional code marks are often used for the production management. In particular, in the production lines of liquid-crystal-display panels and others, data on fabrication processes such as production number and process conditions are written on each substrate or device in detail, and they are used for quality managements. For this reason, lithography system specialized in code mark printing is developed. However, conventional systems using lamp projection exposure or laser scan exposure are very expensive. Therefore, development of a low-cost exposure system using light emitting diodes (LEDs) and optical fibers with squared ends arrayed in a matrix is strongly expected. In the past research, feasibility of such a new exposure system was demonstrated using a handmade system equipped with 100 LEDs with a central wavelength of 405 nm, a 10×10 matrix of optical fibers with 1 mm square ends, and a 10X projection lens. Based on these progresses, a new method for fabricating large-scale arrays of finer fibers with squared ends was developed in this paper. At most 40 plastic optical fibers were arranged in a linear gap of an arraying instrument, and simultaneously squared by heating them on a hotplate at 120°C for 7 min. Fiber sizes were homogeneous within 496+/-4 μm. In addition, average light leak was improved from 34.4 to 21.3% by adopting the new method in place of conventional one by one squaring method. Square matrix arrays necessary for printing code marks will be obtained by piling the newly fabricated linear arrays up.

  20. Laser-induced phase transitions of Ge2Sb2Te5 thin films used in optical and electronic data storage and in thermal lithography.

    PubMed

    Chu, Cheng Hung; Shiue, Chiun Da; Cheng, Hsuen Wei; Tseng, Ming Lun; Chiang, Hai-Pang; Mansuripur, Masud; Tsai, Din Ping

    2010-08-16

    Amorphous thin films of Ge(2)Sb(2)Te(5), sputter-deposited on a ZnS-SiO(2) dielectric layer, are investigated for the purpose of understanding the structural phase-transitions that occur under the influence of tightly-focused laser beams. Selective chemical etching of recorded marks in conjunction with optical, atomic force, and electron microscopy as well as local electron diffraction analysis are used to discern the complex structural features created under a broad range of laser powers and pulse durations. Clarifying the nature of phase transitions associated with laser-recorded marks in chalcogenide Ge(2)Sb(2)Te(5) thin films provides useful information for reversible optical and electronic data storage, as well as for phase-change (thermal) lithography.

  1. Spinning angle optical calibration apparatus

    DOEpatents

    Beer, Stephen K.; Pratt, II, Harold R.

    1991-01-01

    An optical calibration apparatus is provided for calibrating and reproducing spinning angles in cross-polarization, nuclear magnetic resonance spectroscopy. An illuminated magnifying apparatus enables optical setting an accurate reproducing of spinning "magic angles" in cross-polarization, nuclear magnetic resonance spectroscopy experiments. A reference mark scribed on an edge of a spinning angle test sample holder is illuminated by a light source and viewed through a magnifying scope. When the "magic angle" of a sample material used as a standard is attained by varying the angular position of the sample holder, the coordinate position of the reference mark relative to a graduation or graduations on a reticle in the magnifying scope is noted. Thereafter, the spinning "magic angle" of a test material having similar nuclear properties to the standard is attained by returning the sample holder back to the originally noted coordinate position.

  2. Optical coherence tomography and low-frequency mechanics: A moderated discussion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freeman, Dennis M.; Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts; Ruggero, Mario A.

    2015-12-31

    The following is an edited transcript of a recorded discussion session on the topics of “Optical Coherence Tomography” and “Low-Frequency Mechanics”. The discussion, moderated by the authors, took place at the 12{sup th} International Workshop on the Mechanics of Hearing held at Cape Sounio, Greece, in June 2014. All participants knew that the session was being recorded. In view of both the spontaneous nature of the discussion and the editing, however, this transcript may not represent the considered or final views of the participants, and may not represent a consensus of experts in the field. The reader is advised tomore » consult additional independent publications.« less

  3. Dipolar and spinor bosonic systems

    NASA Astrophysics Data System (ADS)

    Yukalov, V. I.

    2018-05-01

    The main properties and methods of describing dipolar and spinor atomic systems, composed of bosonic atoms or molecules, are reviewed. The general approach for the correct treatment of Bose-condensed atomic systems with nonlocal interaction potentials is explained. The approach is applied to Bose-condensed systems with dipolar interaction potentials. The properties of systems with spinor interaction potentials are described. Trapped atoms and atoms in optical lattices are considered. Effective spin Hamiltonians for atoms in optical lattices are derived. The possibility of spintronics with cold atom is emphasized. The present review differs from the previous review articles by concentrating on a thorough presentation of basic theoretical points, helping the reader to better follow mathematical details and to make clearer physical conclusions.

  4. Development of a measuring system of contact force during braille reading using an optical 6-axis force sensor.

    PubMed

    Watanabe, T; Oouchi, S; Yamaguchi, T; Shimojo, M; Shimada, S

    2006-01-01

    A system with an optical 6-axis force sensor was developed to measure contact force during braille reading. In using this system, we encountered two problems. One is a variability of output values depending on the contact point. This was solved by using two transformation techniques. The other is that subjects read braille in a different manner from the usual. We compared two manners of braille reading, one-handed vs two-handed, and found a small reduction in reading speed. Using this system, we collected data from four braille readers and quantitatively showed more minute contact force trajectories than those in earlier studies.

  5. Malthusian Parameters as Estimators of the Fitness of Microbes: A Cautionary Tale about the Low Side of High Throughput.

    PubMed

    Concepción-Acevedo, Jeniffer; Weiss, Howard N; Chaudhry, Waqas Nasir; Levin, Bruce R

    2015-01-01

    The maximum exponential growth rate, the Malthusian parameter (MP), is commonly used as a measure of fitness in experimental studies of adaptive evolution and of the effects of antibiotic resistance and other genes on the fitness of planktonic microbes. Thanks to automated, multi-well optical density plate readers and computers, with little hands-on effort investigators can readily obtain hundreds of estimates of MPs in less than a day. Here we compare estimates of the relative fitness of antibiotic susceptible and resistant strains of E. coli, Pseudomonas aeruginosa and Staphylococcus aureus based on MP data obtained with automated multi-well plate readers with the results from pairwise competition experiments. This leads us to question the reliability of estimates of MP obtained with these high throughput devices and the utility of these estimates of the maximum growth rates to detect fitness differences.

  6. Preserving Simplecticity in the Numerical Integration of Linear Beam Optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, Christopher K.

    2017-07-01

    Presented are mathematical tools and methods for the development of numerical integration techniques that preserve the symplectic condition inherent to mechanics. The intended audience is for beam physicists with backgrounds in numerical modeling and simulation with particular attention to beam optics applications. The paper focuses on Lie methods that are inherently symplectic regardless of the integration accuracy order. Section 2 provides the mathematically tools used in the sequel and necessary for the reader to extend the covered techniques. Section 3 places those tools in the context of charged-particle beam optics; in particular linear beam optics is presented in terms ofmore » a Lie algebraic matrix representation. Section 4 presents numerical stepping techniques with particular emphasis on a third-order leapfrog method. Section 5 discusses the modeling of field imperfections with particular attention to the fringe fields of quadrupole focusing magnets. The direct computation of a third order transfer matrix for a fringe field is shown.« less

  7. Virtual Tool Mark Generation for Efficient Striation Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekstrand, Laura; Zhang, Song; Grieve, Taylor

    2014-02-16

    This study introduces a tool mark analysis approach based upon 3D scans of screwdriver tip and marked plate surfaces at the micrometer scale from an optical microscope. An open-source 3D graphics software package is utilized to simulate the marking process as the projection of the tip's geometry in the direction of tool travel. The edge of this projection becomes a virtual tool mark that is compared to cross-sections of the marked plate geometry using the statistical likelihood algorithm introduced by Chumbley et al. In a study with both sides of six screwdriver tips and 34 corresponding marks, the method distinguishedmore » known matches from known nonmatches with zero false-positive matches and two false-negative matches. For matches, it could predict the correct marking angle within ±5–10°. Individual comparisons could be made in seconds on a desktop computer, suggesting that the method could save time for examiners.« less

  8. Printable Silicon Nanomembranes for Solar-Powered, Bi-Directional Phased-Array-Antenna Communication System on Flexible Substrates

    DTIC Science & Technology

    2013-04-01

    Identification (RFID), Large Area Flexible Displays, Electronic Paper, Bio - Sensors , Large Area Conformal and Flexible Antennas, Smart and Interactive Textiles...Lepeshkin, R. W. Boyd, C. Chase, and J. E. Fajardo, “An environmental sensor based on an integrated optical whispering gallery mode disk resonator ...Ubiquitous Sensor Networks (USN), Vehicle Clickers Readers, Real Time Locating Systems, Lighting, Photovoltaics etc. FA9550-11-C-0014 STTR Phase II

  9. Embodied Cognition and Empathy in Miguel de Cervantes’s El celoso extremeño

    PubMed Central

    Carrera, Elena

    2016-01-01

    This article examines the portrayal of cognitive experience in the published version of Miguel de Cervantes’s short story El celoso extremeño (1613), drawing both on recent studies of empathy and current debates about the inseparability of cognition and emotion. It considers how cognitive experience is marked by particular bodily sensations and shaped by internal representations (i.e., mental images) that are closely tied to emotions such as fear, jealousy, joy, and sorrow. Paying particular attention to the ways in which the narrative underscores the characters’ limited sensory experiences and their defective understanding of each other’s positions, the article argues that this provides the reader with the opportunity to simulate mentally his or her own challenging situations, faulty judgments, and injudicious actions. While being invited to use his or her imagination and judgment to enjoy being placed in a position of greater power and knowledge than the characters, Cervantes’s reader is also encouraged to consider the possibility of not knowing and to accept the limits of empathy. PMID:27807389

  10. Processing Elided Verb Phrases with Flawed Antecedents: the Recycling Hypothesis

    PubMed Central

    Arregui, Ana; Clifton, Charles; Frazier, Lyn; Moulton, Keir

    2006-01-01

    Traditional syntactic accounts of verb phrase ellipsis (e.g. “Jason laughed. Sam did [ ] too.”) categorize as ungrammatical many sentences that language users find acceptable (they “undergenerate”); semantic accounts overgenerate. We propose that a processing theory, together with a syntactic account, does a better job of describing and explaining the data on verb phrase-ellipsis. Five acceptability judgment experiments supported a “VP recycling hypothesis,” which claims that when a syntactically-matching antecedent is not available, the listener/reader creates one using the materials at hand. Experiments 1 and 2 used verb phrase ellipsis sentences with antecedents ranging from perfect (a verb phrase in matrix verb phrase position) to impossible (a verb phrase containing only a deverbal word). Experiments 3 and 4 contrasted antecedents in verbal versus nominal gerund subjects. Experiment 5 explored the possibility that speakers are particularly likely to go beyond the grammar and produce elided constituents without perfect matching antecedents when the antecedent needed is less marked than the antecedent actually produced. This experiment contrasted active (unmarked) and passive antecedents to show that readers seem to honor such a tendency. PMID:17710192

  11. The Contemporary Setting for Water Management in the West: An Overview

    NASA Astrophysics Data System (ADS)

    Cummings, Ronald G.

    1985-11-01

    The socioeconomic, legal, and institutional settings for water resources management and use in the United States have undergone dramatic changes over recent years. The resulting confusion and uncertainties in terms of the structure of water rights, the prerogatives of sovereign states, and the limitations of state-federal interfaces provide the raison d'être for the collection of papers in this special section of Water Resources Research. This special issue is intended to serve several purposes: to inform, to provoke, and to invite. Thus many readers may find new and informative Tarlock's [this issue] overview of the evolution of groundwater law from English Common Law to laws based on notions of "reasonable use" and "sharing"; of particular importance is the readers appreciation of the changes and uncertainties in water law associated with the 1982 decision in Sporhase and in the later El Paso case. These cases, marking an end of the "immunity theory" wherein states were immune, in cases involving resources use, from challenges under the Commerce Clause, give rise to Tarlock's concern with the question, Might current conditions give rise to federal control of groundwater?

  12. [Book review] The history of ornithology in Virginia

    USGS Publications Warehouse

    Robbins, C.S.

    2005-01-01

    Virginia is arguably the birthplace of ornithology in North America. Captain John Smith and naturalist Mark Catesby were among the early describers of Virginia's common birds. David Johnston's book, however, begins by taking the reader back to the Tertiary period, some 65 million years ago, with Storrs Olson's description of fossils from tidewater Virginia. John Guilday, studying bone deposits in mountain caves, identified 80 species of birds, including Rock Ptarmigan and Spruce Grouse, from a time when Virginia's climate differed greatly from that of today. Archaeological studies and accounts of aboriginals in the 17th century complete Chapter 1.

  13. EDITORIAL: Letter from the Editor

    NASA Astrophysics Data System (ADS)

    Hauptmann, Peter

    2008-01-01

    Dear authors and reviewers of articles for Measurement Science and Technology, I would like to thank all those who have published papers with us in 2007, and special thanks go to those of you who have kindly reviewed articles for the journal this year. I would also like to take this opportunity to update you on some of the developments on the journal. As many of you are no doubt aware, our latest impact factor (a measure of the average number of times recent papers are referred to by others) has risen to 1.228. This is often taken as an indication of the quality and relevance of recently published research, and although as readers we develop our own instinct for journals of high quality, it is gratifying as an Editor to see the data from an independent organization agreeing with my own assessment. The popularity of the journal amongst authors and readers has prompted us to introduce a new subject classification for articles, to make it easier for readers to find articles of interest. The eight subject categories are: Measurement theory and practical developments (e.g. precision measurements, metrology, new measurement principles, signal processing techniques, theory of measurement, calibration); Sensors and sensing systems (based on physical, chemical or biological principles; micro- and nano-scale systems; sensors for physical, chemical and biological quantities); Optical and laser based techniques (e.g. fibre optics, interferometry, etc); Fluid mechanics measurements (e.g. fluid flow, velocimetry, particle sizing, etc); Imaging techniques (e.g. tomography, microscopy, holography, THz, etc); Spectroscopy (e.g. optical, acoustic, dielectric, MS, NMR, ESR, IR, UV-VIS, fluorescence, PCS, x-ray, etc); New and improved techniques for materials evaluation (e.g. non-destructive testing and evaluation, structural measurements); Novel instrumentation. We kindly ask you to assign your paper to a category when you send it to the journal. In order to maintain our rapid publication times (currently authors can expect a decision 53 days after submitting their article, and once accepted, articles are published in an average of 40 days), we are adopting an article numbering scheme. This will enable us to continue to publish articles as soon as they are ready, and to classify them according to subject and type. Details can be found on our website at www.iop.org/journals/mst. Another change will be to the names of some of our articles. Design Notes will now be called Technical Design Notes to clarify that these are short descriptive articles giving readers a practical and useful 'how to' guide to a new piece of equipment or a technique. Review Articles will change their name to Topical Reviews to reflect the fact that these provide a review of a topic of current interest. As part of our ongoing initiative to give our authors' work the highest visibility, all articles are freely available online for 30 days from the date of publication, allowing all researchers to read and view the latest research as soon as it is published, and this year there have been many interesting articles to read! As regular readers are aware, Measurement Science and Technology publishes special issues and features, which highlight an area of current interest. Last year's topics included inverse problems in engineering, nanoscale metrology, microwave moisture measurements, metrology for high energy physics experiments and accelerometers, and optical fibre sensors among others. Remember to set up a free e-mail alert so you can be e-mailed as soon as articles in your field are published! There simply remains for me to say thank you again for your contribution to Measurement Science and Technology, and I wish you all the best for a successful 2008!

  14. Optic Nerve Head Biomechanics in Aging and Disease

    PubMed Central

    Downs, J. Crawford

    2015-01-01

    This nontechnical review is focused upon educating the reader on optic nerve head biomechanics in both aging and disease along two main themes: what is known about how mechanical forces and the resulting deformations are distributed in the posterior pole and ONH (biomechanics) and what is known about how the living system responds to those deformations (mechanobiology). We focus on how ONH responds to IOP elevations as a structural system, insofar as the acute mechanical response of the lamina cribrosa is confounded with the responses of the peripapillary sclera, prelaminar neural tissues, and retrolaminar optic nerve. We discuss the biomechanical basis for IOP-driven changes in connective tissues, blood flow, and cellular responses. We use glaucoma as the primary framework to present the important aspects of ONH biomechanics in aging and disease, as ONH biomechanics, aging, and the posterior pole extracellular matrix (ECM) are thought to be centrally involved in glaucoma susceptibility, onset and progression. PMID:25819451

  15. Quantification of dsDNA using the Hitachi F-7000 Fluorescence Spectrophotometer and PicoGreen dye.

    PubMed

    Moreno, Luis A; Cox, Kendra L

    2010-11-05

    Quantification of DNA, especially in small concentrations, is an important task with a wide range of biological applications including standard molecular biology assays such as synthesis and purification of DNA, diagnostic applications such as quantification of DNA amplification products, and detection of DNA molecules in drug preparations. During this video we will demonstrate the capability of the Hitachi F-7000 Fluorescence Spectrophotometer equipped with a Micro Plate Reader accessory to perform dsDNA quantification using Molecular Probes Quant-it PicoGreen dye reagent kit. The F-7000 Fluorescence Spectrophotometer offers high sensitivity and high speed measurements. It is a highly flexible system capable of measuring fluorescence, luminescence, and phosphorescence. Several measuring modes are available, including wavelength scan, time scan, photometry and 3-D scan measurement. The spectrophotometer has sensitivity in the range of 50 picomoles of fluorescein when using a 300 μL sample volume in the microplate, and is capable of measuring scan speeds of 60,000 nm/minute. It also has a wide dynamic range of up to 5 orders of magnitude which allows for the use of calibration curves over a wide range of concentrations. The optical system uses all reflective optics for maximum energy and sensitivity. The standard wavelength range is 200 to 750 nm, and can be extended to 900 nm when using one of the optional near infrared photomultipliers. The system allows optional temperature control for the plate reader from 5 to 60 degrees Celsius using an optional external temperature controlled liquid circulator. The microplate reader allows for the use of 96 well microplates, and the measuring speed for 96 wells is less than 60 seconds when using the kinetics mode. Software controls for the F-7000 and Microplate Reader are also highly flexible. Samples may be set in either column or row formats, and any combination of wells may be chosen for sample measurements. This allows for optimal utilization of the microplate. Additionally, the software allows importing micro plate sample configurations created in Excel and saved in comma separated values, or "csv" format. Microplate measuring configurations can be saved and recalled by the software for convenience and increased productivity. Data results can be output to a standard report, to Excel, or to an optional Report Generator Program.

  16. Quantification of dsDNA using the Hitachi F-7000 Fluorescence Spectrophotometer and PicoGreen Dye

    PubMed Central

    Moreno, Luis A.; Cox, Kendra L.

    2010-01-01

    Quantification of DNA, especially in small concentrations, is an important task with a wide range of biological applications including standard molecular biology assays such as synthesis and purification of DNA, diagnostic applications such as quantification of DNA amplification products, and detection of DNA molecules in drug preparations. During this video we will demonstrate the capability of the Hitachi F-7000 Fluorescence Spectrophotometer equipped with a Micro Plate Reader accessory to perform dsDNA quantification using Molecular Probes Quant-it PicoGreen dye reagent kit. The F-7000 Fluorescence Spectrophotometer offers high sensitivity and high speed measurements. It is a highly flexible system capable of measuring fluorescence, luminescence, and phosphorescence. Several measuring modes are available, including wavelength scan, time scan, photometry and 3-D scan measurement. The spectrophotometer has sensitivity in the range of 50 picomoles of fluorescein when using a 300 μL sample volume in the microplate, and is capable of measuring scan speeds of 60,000 nm/minute. It also has a wide dynamic range of up to 5 orders of magnitude which allows for the use of calibration curves over a wide range of concentrations. The optical system uses all reflective optics for maximum energy and sensitivity. The standard wavelength range is 200 to 750 nm, and can be extended to 900 nm when using one of the optional near infrared photomultipliers. The system allows optional temperature control for the plate reader from 5 to 60 degrees Celsius using an optional external temperature controlled liquid circulator. The microplate reader allows for the use of 96 well microplates, and the measuring speed for 96 wells is less than 60 seconds when using the kinetics mode. Software controls for the F-7000 and Microplate Reader are also highly flexible. Samples may be set in either column or row formats, and any combination of wells may be chosen for sample measurements. This allows for optimal utilization of the microplate. Additionally, the software allows importing micro plate sample configurations created in Excel and saved in comma separated values, or "csv" format. Microplate measuring configurations can be saved and recalled by the software for convenience and increased productivity. Data results can be output to a standard report, to Excel, or to an optional Report Generator Program. PMID:21189464

  17. Method and apparatus for ultra-high-sensitivity, incremental and absolute optical encoding

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B. (Inventor)

    1999-01-01

    An absolute optical linear or rotary encoder which encodes the motion of an object (3) with increased resolution and encoding range and decreased sensitivity to damage to the scale includes a scale (5), which moves with the object and is illuminated by a light source (11). The scale carries a pattern (9) which is imaged by a microscope optical system (13) on a CCD array (17) in a camera head (15). The pattern includes both fiducial markings (31) which are identical for each period of the pattern and code areas (33) which include binary codings of numbers identifying the individual periods of the pattern. The image of the pattern formed on the CCD array is analyzed by an image processor (23) to locate the fiducial marking, decode the information encoded in the code area, and thereby determine the position of the object.

  18. Pre-polishing on a CNC platform with bound abrasive contour tools

    NASA Astrophysics Data System (ADS)

    Schoeffer, Adrienne E.

    2003-05-01

    Deterministic micorgrinding (DMG) of optical glasses and ceramics is the commercial manufacturing process of choice to shape glass surfaces prior to final finishing. This process employs rigid bound matrix diamond tooling resulting in surface roughness values of 3-51.tm peak to valley and 100-400nm rms, as well as mid-spatial frequency tool marks that require subsequent removal in secondary finishing steps. The ability to pre-polish optical surfaces within the grinding platform would reduce final finishing process times. Bound abrasive contour wheels containing cerium oxide, alumina or zirconia abrasives were constructed with an epoxy matrix. The effects of abrasive type, composition, and erosion promoters were examined for tool hardness (Shore D), and tested with commercial optical glasses in an OptiproTM CNC grinding platform. Metrology protocols were developed to examine tool wear and subsequent surface roughness. Work is directed to demonstrating effective material removal, improved surface roughness and cutter mark removal.

  19. Prepolishing on a CNC platform with bound abrasive contour tools

    NASA Astrophysics Data System (ADS)

    Schoeffler, Adrienne E.; Gregg, Leslie L.; Schoen, John M.; Fess, Edward M.; Hakiel, Michael; Jacobs, Stephen D.

    2003-05-01

    Deterministic microgrinding (DMG) of optical glasses and ceramics is the commercial manufacturing process of choice to shape glass surfaces prior to final finishing. This process employs rigid bound matrix diamond tooling resulting in surface roughness values of 3-5μm peak to valley and 100-400nm rms, as well as mid-spatial frequency tool marks that require subsequent removal in secondary finishing steps. The ability to pre-polish optical surfaces within the grinding platform would reduce final finishing process times. Bound abrasive contour wheels containing cerium oxide, alumina or zirconia abrasives were constructed with an epoxy matrix. The effects of abrasive type, composition, and erosion promoters were examined for tool hardness (Shore D), and tested with commercial optical glasses in an Optipro CNC grinding platform. Metrology protocols were developed to examine tool wear and subsequent surface roughness. Work is directed to demonstrating effective material removal, improved surface roughness and cutter mark removal.

  20. Spinning angle optical calibration apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beer, S.K.; Pratt, H.R. II.

    1989-09-12

    An optical calibration apparatus is provided for calibrating and reproducing spinning angles in cross-polarization, nuclear magnetic resonance spectroscopy. An illuminated magnifying apparatus enables optical setting and accurate reproducing of spinning magic angles in cross-polarization, nuclear magnetic resonance spectroscopy experiments. A reference mark scribed on an edge of a spinning angle test sample holder is illuminated by a light source and viewed through a magnifying scope. When the magic angle of a sample material used as a standard is attained by varying the angular position of the sample holder, the coordinate position of the reference mark relative to a graduation ormore » graduations on a reticle in the magnifying scope is noted. Thereafter, the spinning magic angle of a test material having similar nuclear properties to the standard is attained by returning the sample holder back to the originally noted coordinate position. 2 figs.« less

  1. Microplate-reader method for the rapid analysis of copper in natural waters with chemiluminescence detection.

    PubMed

    Durand, Axel; Chase, Zanna; Remenyi, Tomas; Quéroué, Fabien

    2012-01-01

    We have developed a method for the determination of copper in natural waters at nanomolar levels. The use of a microplate-reader minimizes sample processing time (~25 s per sample), reagent consumption (~120 μL per sample), and sample volume (~700 μL). Copper is detected by chemiluminescence. This technique is based on the formation of a complex between copper and 1,10-phenanthroline and the subsequent emission of light during the oxidation of the complex by hydrogen peroxide. Samples are acidified to pH 1.7 and then introduced directly into a 24-well plate. Reagents are added during data acquisition via two reagent injectors. When trace metal clean protocols are employed, the reproducibility is generally less than 7% on blanks and the detection limit is 0.7 nM for seawater and 0.4 nM for freshwater. More than 100 samples per hour can be analyzed with this technique, which is simple, robust, and amenable to at-sea analysis. Seawater samples from Storm Bay in Tasmania illustrate the utility of the method for environmental science. Indeed other trace metals for which optical detection methods exist (e.g., chemiluminescence, fluorescence, and absorbance) could be adapted to the microplate-reader.

  2. The use of hippocampal volumetric measurements to improve diagnostic accuracy in pediatric patients with mesial temporal sclerosis.

    PubMed

    Guzmán Pérez-Carrillo, Gloria J; Owen, Christopher; Schwetye, Katherine E; McFarlane, Spencer; Vellimana, Ananth K; Mar, Soe; Miller-Thomas, Michelle M; Shimony, Joshua S; Smyth, Matthew D; Benzinger, Tammie L S

    2017-06-01

    OBJECTIVE Many patients with medically intractable epilepsy have mesial temporal sclerosis (MTS), which significantly affects their quality of life. The surgical excision of MTS lesions can result in marked improvement or even complete resolution of the epileptic episodes. Reliable radiological diagnosis of MTS is a clinical challenge. The purpose of this study was to evaluate the utility of volumetric mapping of the hippocampi for the identification of MTS in a case-controlled series of pediatric patients who underwent resection for medically refractory epilepsy, using pathology as a gold standard. METHODS A cohort of 57 pediatric patients who underwent resection for medically intractable epilepsy between 2005 and 2015 was evaluated. On pathological investigation, this group included 24 patients with MTS and 33 patients with non-MTS findings. Retrospective quantitative volumetric measurements of the hippocampi were acquired for 37 of these 57 patients. Two neuroradiologists with more than 10 years of experience who were blinded to the patients' MTS status performed the retrospective review of MR images. To produce the volumetric data, MR scans were parcellated and segmented using the FreeSurfer software suite. Hippocampal regions of interest were compared against an age-weighted local regression curve generated with data from the pediatric normal cohort. Standard deviations and percentiles of specific subjects were calculated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined for the original clinical read and the expert readers. Receiver operating characteristic curves were generated for the methods of classification to compare results from the readers with the authors' results, and an optimal threshold was determined. From that threshold the sensitivity, specificity, PPV, and NPV were calculated for the volumetric analysis. RESULTS With the use of quantitative volumetry, a sensitivity of 72%, a specificity of 95%, a PPV of 93%, an NPV of 78%, and an area under the curve of 0.84 were obtained using a percentage difference of normalized hippocampal volume. The resulting specificity (95%) and PPV (93%) are superior to the original clinical read and to Reader A and Reader B's findings (range for specificity 74%-86% and for PPV 64%-71%). The sensitivity (72%) and NPV (78%) are comparable to Reader A's findings (73% and 81%, respectively) and are better than those of the original clinical read and of Reader B (sensitivity 45% and 63% and NPV 71% and 70%, respectively). CONCLUSIONS Volumetric measurement of the hippocampi outperforms expert readers in specificity and PPV, and it demonstrates comparable to superior sensitivity and NPV. Volumetric measurements can complement anatomical imaging for the identification of MTS, much like a computer-aided detection tool would. The implementation of this approach in the daily clinical workflow could significantly improve diagnostic accuracy.

  3. EDITORIAL: Metrologia

    NASA Astrophysics Data System (ADS)

    Blackburn, D. A.

    1991-01-01

    Visually, this issue of Metrologia differs markedly from those of recent years. The cover is changed and the layout of articles is not quite what it was before. Older readers, however, may notice that the colour of our new cover is that used for the original eleven volumes published in the period 1965-1975. The choice is deliberate: this combination of innovation with a respect for older forms characterizes the way Metrologia will operate under its new publisher the Bureau International des Poids et Mesures. In discussion of the new Metrologia, one decision was firm: our underlying editorial policy remains fixed. Metrologia will remain a primary vehicle through which the metrological community communicates progress in fundamental scientific measurements, reports original experiments and techniques, reviews work in specialist fields and disseminates the decisions of the Comité International des Poids et Mesures. This year, we plan six issues. Four will be regular research issues, one, appearing mid-Summer, will record the proceedings of the meeting held in Davos, Switzerland 20-22 September 1990 on "New Developments and Advances in Optical Radiometry III" and another, towards the end of the year, will review progress in Nanometrology. If successful, the pattern will be repeated, the intention being that the research issues continue Metrologia's historical line of interest, the conference issues expose the journal to new authors and the review issues realize a long-standing, but largely inactive, objective of editorial policy, the provision of retrospective evaluations of important topics and the assessment of likely developments in selected aspects of metrology.

  4. Optic disc segmentation for glaucoma screening system using fundus images.

    PubMed

    Almazroa, Ahmed; Sun, Weiwei; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-01-01

    Segmenting the optic disc (OD) is an important and essential step in creating a frame of reference for diagnosing optic nerve head pathologies such as glaucoma. Therefore, a reliable OD segmentation technique is necessary for automatic screening of optic nerve head abnormalities. The main contribution of this paper is in presenting a novel OD segmentation algorithm based on applying a level set method on a localized OD image. To prevent the blood vessels from interfering with the level set process, an inpainting technique was applied. As well an important contribution was to involve the variations in opinions among the ophthalmologists in detecting the disc boundaries and diagnosing the glaucoma. Most of the previous studies were trained and tested based on only one opinion, which can be assumed to be biased for the ophthalmologist. In addition, the accuracy was calculated based on the number of images that coincided with the ophthalmologists' agreed-upon images, and not only on the overlapping images as in previous studies. The ultimate goal of this project is to develop an automated image processing system for glaucoma screening. The disc algorithm is evaluated using a new retinal fundus image dataset called RIGA (retinal images for glaucoma analysis). In the case of low-quality images, a double level set was applied, in which the first level set was considered to be localization for the OD. Five hundred and fifty images are used to test the algorithm accuracy as well as the agreement among the manual markings of six ophthalmologists. The accuracy of the algorithm in marking the optic disc area and centroid was 83.9%, and the best agreement was observed between the results of the algorithm and manual markings in 379 images.

  5. Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam.

    PubMed

    Balsam, Joshua; Bruck, Hugh Alan; Kostov, Yordan; Rasooly, Avraham

    2012-01-01

    Optical technologies are important for biological analysis. Current biomedical optical analyses rely on high-cost, high-sensitivity optical detectors such as photomultipliers, avalanched photodiodes or cooled CCD cameras. In contrast, Webcams, mobile phones and other popular consumer electronics use lower-sensitivity, lower-cost optical components such as photodiodes or CMOS sensors. In order for consumer electronics devices, such as webcams, to be useful for biomedical analysis, they must have increased sensitivity. We combined two strategies to increase the sensitivity of CMOS-based fluorescence detector. We captured hundreds of low sensitivity images using a Webcam in video mode, instead of a single image typically used in cooled CCD devices.We then used a computational approach consisting of an image stacking algorithm to remove the noise by combining all of the images into a single image. While video mode is widely used for dynamic scene imaging (e.g. movies or time-lapse photography), it is not used to capture a single static image, which removes noise and increases sensitivity by more than thirty fold. The portable, battery-operated Webcam-based fluorometer system developed here consists of five modules: (1) a low cost CMOS Webcam to monitor light emission, (2) a plate to perform assays, (3) filters and multi-wavelength LED illuminator for fluorophore excitation, (4) a portable computer to acquire and analyze images, and (5) image stacking software for image enhancement. The samples consisted of various concentrations of fluorescein, ranging from 30 μM to 1000 μM, in a 36-well miniature plate. In the single frame mode, the fluorometer's limit-of-detection (LOD) for fluorescein is ∼1000 μM, which is relatively insensitive. However, when used in video mode combined with image stacking enhancement, the LOD is dramatically reduced to 30 μM, sensitivity which is similar to that of state-of-the-art ELISA plate photomultiplier-based readers. Numerous medical diagnostics assays rely on optical and fluorescence readers. Our novel combination of detection technologies, which is new to biodetection may enable the development of new low cost optical detectors based on an inexpensive Webcam (<$10). It has the potential to form the basis for high sensitivity, low cost medical diagnostics in resource-poor settings.

  6. Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam

    PubMed Central

    Balsam, Joshua; Bruck, Hugh Alan; Kostov, Yordan; Rasooly, Avraham

    2013-01-01

    Optical technologies are important for biological analysis. Current biomedical optical analyses rely on high-cost, high-sensitivity optical detectors such as photomultipliers, avalanched photodiodes or cooled CCD cameras. In contrast, Webcams, mobile phones and other popular consumer electronics use lower-sensitivity, lower-cost optical components such as photodiodes or CMOS sensors. In order for consumer electronics devices, such as webcams, to be useful for biomedical analysis, they must have increased sensitivity. We combined two strategies to increase the sensitivity of CMOS-based fluorescence detector. We captured hundreds of low sensitivity images using a Webcam in video mode, instead of a single image typically used in cooled CCD devices.We then used a computational approach consisting of an image stacking algorithm to remove the noise by combining all of the images into a single image. While video mode is widely used for dynamic scene imaging (e.g. movies or time-lapse photography), it is not used to capture a single static image, which removes noise and increases sensitivity by more than thirty fold. The portable, battery-operated Webcam-based fluorometer system developed here consists of five modules: (1) a low cost CMOS Webcam to monitor light emission, (2) a plate to perform assays, (3) filters and multi-wavelength LED illuminator for fluorophore excitation, (4) a portable computer to acquire and analyze images, and (5) image stacking software for image enhancement. The samples consisted of various concentrations of fluorescein, ranging from 30 μM to 1000 μM, in a 36-well miniature plate. In the single frame mode, the fluorometer's limit-of-detection (LOD) for fluorescein is ∼1000 μM, which is relatively insensitive. However, when used in video mode combined with image stacking enhancement, the LOD is dramatically reduced to 30 μM, sensitivity which is similar to that of state-of-the-art ELISA plate photomultiplier-based readers. Numerous medical diagnostics assays rely on optical and fluorescence readers. Our novel combination of detection technologies, which is new to biodetection may enable the development of new low cost optical detectors based on an inexpensive Webcam (<$10). It has the potential to form the basis for high sensitivity, low cost medical diagnostics in resource-poor settings. PMID:23990697

  7. Miniaturised wireless smart tag for optical chemical analysis applications.

    PubMed

    Steinberg, Matthew D; Kassal, Petar; Tkalčec, Biserka; Murković Steinberg, Ivana

    2014-01-01

    A novel miniaturised photometer has been developed as an ultra-portable and mobile analytical chemical instrument. The low-cost photometer presents a paradigm shift in mobile chemical sensor instrumentation because it is built around a contactless smart card format. The photometer tag is based on the radio-frequency identification (RFID) smart card system, which provides short-range wireless data and power transfer between the photometer and a proximal reader, and which allows the reader to also energise the photometer by near field electromagnetic induction. RFID is set to become a key enabling technology of the Internet-of-Things (IoT), hence devices such as the photometer described here will enable numerous mobile, wearable and vanguard chemical sensing applications in the emerging connected world. In the work presented here, we demonstrate the characterisation of a low-power RFID wireless sensor tag with an LED/photodiode-based photometric input. The performance of the wireless photometer has been tested through two different model analytical applications. The first is photometry in solution, where colour intensity as a function of dye concentration was measured. The second is an ion-selective optode system in which potassium ion concentrations were determined by using previously well characterised bulk optode membranes. The analytical performance of the wireless photometer smart tag is clearly demonstrated by these optical absorption-based analytical experiments, with excellent data agreement to a reference laboratory instrument. © 2013 Elsevier B.V. All rights reserved.

  8. [Cognitive disorders in patients with chronic mercury intoxication].

    PubMed

    Katamanova, E V; Shevchenko, O I; Lakhman, O L; Denisova, I A

    2014-01-01

    To assess severity of cognitive disorders in chronic mercury intoxication, the authors performed claster and discrimination analysis of neuropsychologic and neurophysiologic research data from workers exposed to mercury during long length of service, from patients with early and marked stages of chronic mercurial intoxication. Cognitive disorders in chronic mercurial intoxication have three severity degrees, in the light degree disorders patients demonstrate lower amplitude of cognitive evoked potentials, poor long-term memory and associative thinking. Moderate cognitive disorders are characterized by decreased visual, long-term memory, concentration of attention, poor optic and spatial gnosis. Marked cognitive disorders with chronic mercurial intoxication present with more decreased long-term, short-term, picturesque memory, poor intellect, optic and spatial gnosis and associative thinking.

  9. Galaxy And Mass Assembly (GAMA): the signatures of galaxy interactions as viewed from small scale galaxy clustering

    NASA Astrophysics Data System (ADS)

    Gunawardhana, M. L. P.; Norberg, P.; Zehavi, I.; Farrow, D. J.; Loveday, J.; Hopkins, A. M.; Davies, L. J. M.; Wang, L.; Alpaslan, M.; Bland-Hawthorn, J.; Brough, S.; Holwerda, B. W.; Owers, M. S.; Wright, A. H.

    2018-06-01

    Statistical studies of galaxy-galaxy interactions often utilise net change in physical properties of progenitors as a function of the separation between their nuclei to trace both the strength and the observable timescale of their interaction. In this study, we use two-point auto, cross and mark correlation functions to investigate the extent to which small-scale clustering properties of star forming galaxies can be used to gain physical insight into galaxy-galaxy interactions between galaxies of similar optical brightness and stellar mass. The Hα star formers, drawn from the highly spatially complete Galaxy And Mass Assembly (GAMA) survey, show an increase in clustering on small separations. Moreover, the clustering strength shows a strong dependence on optical brightness and stellar mass, where (1) the clustering amplitude of optically brighter galaxies at a given separation is larger than that of optically fainter systems, (2) the small scale clustering properties (e.g. the strength, the scale at which the signal relative to the fiducial power law plateaus) of star forming galaxies appear to differ as a function of increasing optical brightness of galaxies. According to cross and mark correlation analyses, the former result is largely driven by the increased dust content in optically bright star forming galaxies. The latter could be interpreted as evidence of a correlation between interaction-scale and optical brightness of galaxies, where physical evidence of interactions between optically bright star formers, likely hosted within relatively massive halos, persist over larger separations than those between optically faint star formers.

  10. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance.

    PubMed

    Guggenberger, Roman; Ulbrich, Erika J; Dietrich, Tobias J; Scholz, Rosemarie; Kaelin, Pascal; Köhler, Christoph; Elsässer, Thilo; Le Corroller, Thomas; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav

    2017-02-01

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between к = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. • FPCT shoulder arthrography is feasible with fluoroscopy and CT in one workflow. • A 5-s FPCT protocol applies a lower radiation dose than MDCT. • A 20-s FPCT protocol is moderately sensitive for cartilage and tendon pathology.

  11. Airborne-Fiber Optics Manufacturing Technology, Aircraft Installation Processes.

    DTIC Science & Technology

    1980-08-19

    but the impact is minor. With simpler equipment and techniques there may be a J’ 1 -, long- term savings potential. Overall costs and benefits of...4/72 1 * lh427 ,. . . ... .. - - . .. . 4.0 ASSEMBLY OF FIBER OPTIC CABLES AND HARNESSES 4.1 CABLE IDENTIFICATION (Marking) 4.1.1 Physically identify...FIBER OPTICS MANUFACTURING TECHNOLOGY Aircraft Installation Processes G Kosmos ~ ~ 19 August 1980 I 2 Final Report: May 1978 - June 1980 . 1 Prepared for

  12. Demonstrations of Optical Spectra with a Video Camera

    ERIC Educational Resources Information Center

    Kraftmakher, Yaakov

    2012-01-01

    The use of a video camera may markedly improve demonstrations of optical spectra. First, the output electrical signal from the camera, which provides full information about a picture to be transmitted, can be used for observing the radiant power spectrum on the screen of a common oscilloscope. Second, increasing the magnification by the camera…

  13. Contrast-enhanced 3-dimensional SPACE versus MP-RAGE for the detection of brain metastases: considerations with a 32-channel head coil.

    PubMed

    Reichert, Miriam; Morelli, John N; Runge, Val M; Tao, Ai; von Ritschl, Ruediger; von Ritschl, Andreas; Padua, Abraham; Dix, James E; Marra, Michael J; Schoenberg, Stefan O; Attenberger, Ulrike I

    2013-01-01

    The aim of this study was to compare the detection of brain metastases at 3 T using a 32-channel head coil with 2 different 3-dimensional (3D) contrast-enhanced sequences, a T1-weighted fast spin-echo-based (SPACE; sampling perfection with application-optimized contrasts using different flip angle evolutions) sequence and a conventional magnetization-prepared rapid gradient-echo (MP-RAGE) sequence. Seventeen patients with 161 brain metastases were examined prospectively using both SPACE and MP-RAGE sequences on a 3-T magnetic resonance system. Eight healthy volunteers were similarly examined for determination of signal-to-noise ratio (SNR) values. Parameters were adjusted to equalize acquisition times between the sequences (3 minutes and 30 seconds). The order in which sequences were performed was randomized. Two blinded board-certified neuroradiologists evaluated the number of detectable metastatic lesions with each sequence relative to a criterion standard reading conducted at the Gamma Knife facility by a neuroradiologist with access to all clinical and imaging data. In the volunteer assessment with SPACE and MP-RAGE, SNR (10.3 ± 0.8 vs 7.7 ± 0.7) and contrast-to-noise ratio (0.8 ± 0.2 vs 0.5 ± 0.1) were statistically significantly greater with the SPACE sequence (P < 0.05). Overall, lesion detection was markedly improved with the SPACE sequence (99.1% of lesions for reader 1 and 96.3% of lesions for reader 2) compared with the MP-RAGE sequence (73.6% of lesions for reader 1 and 68.5% of lesions for reader 2; P < 0.01). A 3D T1-weighted fast spin echo sequence (SPACE) improves detection of metastatic lesions relative to 3D T1-weighted gradient-echo-based scan (MP-RAGE) imaging when implemented with a 32-channel head coil at identical scan acquisition times (3 minutes and 30 seconds).

  14. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging

    PubMed Central

    Morris, Elizabeth A.; Kaplan, Jennifer B.; D’Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S.

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material–enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board–approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%–76%) and MR imaging (69%–76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55–0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA, 2016 PMID:27379544

  15. Towards in vivo laser coagulation and concurrent optical coherence tomography through double-clad fiber devices

    NASA Astrophysics Data System (ADS)

    Beaudette, Kathy; Lo, William; Villiger, Martin; Shishkov, Milen; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline

    2016-03-01

    There is a strong clinical need for an optical coherence tomography (OCT) system capable of delivering concurrent coagulation light enabling image-guided dynamic laser marking for targeted collection of biopsies, as opposed to a random sampling, to reduce false-negative findings. Here, we present a system based on double-clad fiber (DCF) capable of delivering pulsed laser light through the inner cladding while performing OCT through the core. A previously clinically validated commercial OCT system (NVisionVLE, Ninepoint Medical) was adapted to enable in vivo esophageal image-guided dynamic laser marking. An optimized DCF coupler was implemented into the system to couple both modalities into the DCF. A DCF-based rotary joint was used to couple light to the spinning DCF-based catheter for helical scanning. DCF-based OCT catheters, providing a beam waist diameter of 62μm at a working distance of 9.3mm, for use with a 17-mm diameter balloon sheath, were used for ex vivo imaging of a swine esophagus. Imaging results using the DCF-based clinical system show an image quality comparable with a conventional system with minimal crosstalk-induced artifacts. To further optimize DCF catheter optical design in order to achieve single-pulse marking, a Zemax model of the DCF output and its validation are presented.

  16. Protein and DNA Modifications: Evolutionary Imprints of Bacterial Biochemical Diversification and Geochemistry on the Provenance of Eukaryotic Epigenetics

    PubMed Central

    Aravind, L.; Burroughs, A. Maxwell; Zhang, Dapeng; Iyer, Lakshminarayan M.

    2014-01-01

    Epigenetic information, which plays a major role in eukaryotic biology, is transmitted by covalent modifications of nuclear proteins (e.g., histones) and DNA, along with poorly understood processes involving cytoplasmic/secreted proteins and RNAs. The origin of eukaryotes was accompanied by emergence of a highly developed biochemical apparatus for encoding, resetting, and reading covalent epigenetic marks in proteins such as histones and tubulins. The provenance of this apparatus remained unclear until recently. Developments in comparative genomics show that key components of eukaryotic epigenetics emerged as part of the extensive biochemical innovation of secondary metabolism and intergenomic/interorganismal conflict systems in prokaryotes, particularly bacteria. These supplied not only enzymatic components for encoding and removing epigenetic modifications, but also readers of some of these marks. Diversification of these prokaryotic systems and subsequently eukaryotic epigenetics appear to have been considerably influenced by the great oxygenation event in the Earth’s history. PMID:24984775

  17. Protein and DNA modifications: evolutionary imprints of bacterial biochemical diversification and geochemistry on the provenance of eukaryotic epigenetics.

    PubMed

    Aravind, L; Burroughs, A Maxwell; Zhang, Dapeng; Iyer, Lakshminarayan M

    2014-07-01

    Epigenetic information, which plays a major role in eukaryotic biology, is transmitted by covalent modifications of nuclear proteins (e.g., histones) and DNA, along with poorly understood processes involving cytoplasmic/secreted proteins and RNAs. The origin of eukaryotes was accompanied by emergence of a highly developed biochemical apparatus for encoding, resetting, and reading covalent epigenetic marks in proteins such as histones and tubulins. The provenance of this apparatus remained unclear until recently. Developments in comparative genomics show that key components of eukaryotic epigenetics emerged as part of the extensive biochemical innovation of secondary metabolism and intergenomic/interorganismal conflict systems in prokaryotes, particularly bacteria. These supplied not only enzymatic components for encoding and removing epigenetic modifications, but also readers of some of these marks. Diversification of these prokaryotic systems and subsequently eukaryotic epigenetics appear to have been considerably influenced by the great oxygenation event in the Earth's history. Copyright © 2014 Cold Spring Harbor Laboratory Press; all rights reserved.

  18. Development and Application of Advanced Ophthalmic Imaging Technology to Enhance Military Ocular Health Capabilities

    DTIC Science & Technology

    2008-04-01

    V. X. D. Yang, M. L. Gordon, A. Mok, Y. Zhao, Z. Chen, R. Cobbold , B. Wilson, and I. Vitkin, " Improve.d pha<e. re;olve.d optical Doppler tomography... marked according to visualmea~urement (b), rutd the result of the moving circular window filtering. In this case, the location of the mininttun...botmdaries are marked on the OCT image; (g). The ODT image for the same OCT scan; (h). Magnified \\<iew of the region marked in (_ll,). where. the

  19. Lightweight ZERODUR: Validation of Mirror Performance and Mirror Modeling Predictions

    NASA Technical Reports Server (NTRS)

    Hull, Tony; Stahl, H. Philip; Westerhoff, Thomas; Valente, Martin; Brooks, Thomas; Eng, Ron

    2017-01-01

    Upcoming spaceborne missions, both moderate and large in scale, require extreme dimensional stability while relying both upon established lightweight mirror materials, and also upon accurate modeling methods to predict performance under varying boundary conditions. We describe tests, recently performed at NASA's XRCF chambers and laboratories in Huntsville Alabama, during which a 1.2 m diameter, f/1.2988% lightweighted SCHOTT lightweighted ZERODUR(TradeMark) mirror was tested for thermal stability under static loads in steps down to 230K. Test results are compared to model predictions, based upon recently published data on ZERODUR(TradeMark). In addition to monitoring the mirror surface for thermal perturbations in XRCF Thermal Vacuum tests, static load gravity deformations have been measured and compared to model predictions. Also the Modal Response(dynamic disturbance) was measured and compared to model. We will discuss the fabrication approach and optomechanical design of the ZERODUR(TradeMark) mirror substrate by SCHOTT, its optical preparation for test by Arizona Optical Systems (AOS). Summarize the outcome of NASA's XRCF tests and model validations

  20. Firefly: an optical lithographic system for the fabrication of holographic security labels

    NASA Astrophysics Data System (ADS)

    Calderón, Jorge; Rincón, Oscar; Amézquita, Ricardo; Pulido, Iván.; Amézquita, Sebastián.; Bernal, Andrés.; Romero, Luis; Agudelo, Viviana

    2016-03-01

    This paper introduces Firefly, an optical lithography origination system that has been developed to produce holographic masters of high quality. This mask-less lithography system has a resolution of 418 nm half-pitch, and generates holographic masters with the optical characteristics required for security applications of level 1 (visual verification), level 2 (pocket reader verification) and level 3 (forensic verification). The holographic master constitutes the main core of the manufacturing process of security holographic labels used for the authentication of products and documents worldwide. Additionally, the Firefly is equipped with a software tool that allows for the hologram design from graphic formats stored in bitmaps. The software is capable of generating and configuring basic optical effects such as animation and color, as well as effects of high complexity such as Fresnel lenses, engraves and encrypted images, among others. The Firefly technology gathers together optical lithography, digital image processing and the most advanced control systems, making possible a competitive equipment that challenges the best technologies in the industry of holographic generation around the world. In this paper, a general description of the origination system is provided as well as some examples of its capabilities.

  1. Walter Thompson Welford 31 August 1916 - 18 September 1990.

    PubMed

    Barnett, Michael; Smith, Robin

    2004-01-01

    Walter Thompson Welford (Walter Weinstein until 1957), born in London, left Hackney Technical Institute at the age of 16 years to become a technician at the London Hospital and later at Oxford University Biochemistry Department. In 1942, after obtaining a first-class honours external degree in mathematics from London University by private study, he returned to London to work at Adam Hilger Ltd. He moved to Imperial College, London, as a research assistant in 1947, became a lecturer in 1951, a senior lecturer in 1959, Reader in 1964 and Professor of Physics in 1973. He was elected a Fellow of The Royal Society in 1980. After formal retirement in 1983 he continued to be research active at Imperial College and the University of Chicago until his death from throat cancer in 1990.Walter's scientific work was in the craft of optical instrumentation, in which he became an internationally recognized master. His contributions ranged from basic aberration theory to the design, construction and testing of a vast ranger of optical instrumentation. His research fields were principally lens aberrations, optical microscopy, bubble chamber optics, laser speckle, non-imaging optics, diffraction gratings and diffraction lenses. Many will also remember him as a kindly and inspiring educator.

  2. Optical coherence tomography angiography in glaucoma care.

    PubMed

    Chansangpetch, Sunee; Lin, Shan C

    2018-05-14

    Rapid improvements in optical coherence tomography (OCT) technology have allowed for enhancement of both image resolution and scanning speed, and the development of vascular assessment modality. Optical coherence tomography angiography (OCTA) is the non-invasive in vivo imaging of the vasculature located within the retina and optic nerve head area. The principle of OCTA is to use the variations in OCT signals caused by moving particles as the contrast mechanism for imaging of flow. Several algorithms which aim to maximize the contrast signal and minimize the noise have been developed including the phase-based techniques, intensity-based techniques (e.g., split-spectrum amplitude decorrelation angiography (SSADA)), and complex-based techniques (e.g., optical microangiography (OMAG)). With its reliable technique, high image resolution, and current availability, OCTA has been widely used in the assessment of posterior segment diseases including glaucoma in which ocular perfusion dysfunction has been proposed as a pathophysiological mechanism. This review will provide the reader with information on the principle techniques of OCTA; the current literature on OCTA reproducibility; its applications to glaucoma detection and monitoring of progression; and the role of OCTA in the assessment of the vascular component in glaucoma pathogenesis.

  3. Reproducibility of the Carpet View system: a novel technical solution for display and off line analysis of OCT images.

    PubMed

    Gabriele, Alex; Marco, Valeria; Gatto, Laura; Paoletti, Giulia; Di Vito, Luca; Castriota, Fausto; Romagnoli, Enrico; Ricciardi, Andrea; Prati, Francesco

    2014-10-01

    The optical coherence tomography (OCT) evaluation of the stent anatomy requires the inspection of sequential cross section (CS). However stent coils cannot be appreciated in the conventional format as the OCT CS simply display stent struts, that are poorly representative of the stent architecture. The aim of the present study was to validate a new software (Carpet View), which unfolds the stented segment, reconstructing it as an open structure and displaying the stent meshwork. 21 patients were studied with frequency domain OCT after the deployment of different stents: seven bio-absorbable scaffolds (Dream), seven bare metal stent (Vision/Multilink8), seven drug eluting stent (Cre8). Conventional CS reconstructions were post-processed with the Carpet View software and analyzed by the same reader twice (intra-observer variability) and by two different readers (inter-observer variability). A small average difference in the number of all struts was obtained with the two methods (conventional vs carpet view reconstruction). Using the carpet view, high intra-observer and inter-observer correlations were found for the number of struts obtained in each coil. The Pearson correlation values were 0.98 (p = 0.0001) and 0.96 (p = 0.0001) respectively. The same number of coils was found when analyses were repeated by the same reader or by a different reader whilst mild differences in the count of stent junctions were reported. The Carpet View can be used to address the stent geometry with high reproducibility. This approach enables the matching of the same stent portion during serial time points and promises to improve the stent assessment.

  4. Smartphone, tablet computer and e-reader use by people with vision impairment.

    PubMed

    Crossland, Michael D; Silva, Rui S; Macedo, Antonio F

    2014-09-01

    Consumer electronic devices such as smartphones, tablet computers, and e-book readers have become far more widely used in recent years. Many of these devices contain accessibility features such as large print and speech. Anecdotal experience suggests people with vision impairment frequently make use of these systems. Here we survey people with self-identified vision impairment to determine their use of this equipment. An internet-based survey was advertised to people with vision impairment by word of mouth, social media, and online. Respondents were asked demographic information, what devices they owned, what they used these devices for, and what accessibility features they used. One hundred and thirty-two complete responses were received. Twenty-six percent of the sample reported that they had no vision and the remainder reported they had low vision. One hundred and seven people (81%) reported using a smartphone. Those with no vision were as likely to use a smartphone or tablet as those with low vision. Speech was found useful by 59% of smartphone users. Fifty-one percent of smartphone owners used the camera and screen as a magnifier. Forty-eight percent of the sample used a tablet computer, and 17% used an e-book reader. The most frequently cited reason for not using these devices included cost and lack of interest. Smartphones, tablet computers, and e-book readers can be used by people with vision impairment. Speech is used by people with low vision as well as those with no vision. Many of our (self-selected) group used their smartphone camera and screen as a magnifier, and others used the camera flash as a spotlight. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  5. Development of a personal dosimetry system based on optically stimulated luminescence of alpha-Al2O3:C for mixed radiation fields.

    PubMed

    Lee, S Y; Lee, K J

    2001-04-01

    To develop a personal optically stimulated luminescence (OSL) dosimetry system for mixed radiation fields using alpha-Al2O3:C, a discriminating badge filter system was designed by taking advantage of its optically stimulable properties and energy dependencies. This was done by designing a multi-element badge system for powder layered alpha-Al2O3:C material and an optical reader system based on high-intensity blue light-emitting diode (LED). The design of the multielement OSL dosimeter badge system developed allows the measurement of a personal dose equivalent value Hp(d) in mixed radiation fields of beta and gamma. Dosimetric properties of the personal OSL dosimeter badge system investigated here were the dose response, energy response and multi-readability. Based on the computational simulations and experiments of the proposed dosimeter design, it was demonstrated that a multi-element dosimeter system with an OSL technology based on alpha-Al2O3:C is suitable to obtain personal dose equivalent information in mixed radiation fields.

  6. Druggability of methyl-lysine binding sites

    NASA Astrophysics Data System (ADS)

    Santiago, C.; Nguyen, K.; Schapira, M.

    2011-12-01

    Structural modules that specifically recognize—or read—methylated or acetylated lysine residues on histone peptides are important components of chromatin-mediated signaling and epigenetic regulation of gene expression. Deregulation of epigenetic mechanisms is associated with disease conditions, and antagonists of acetyl-lysine binding bromodomains are efficacious in animal models of cancer and inflammation, but little is known regarding the druggability of methyl-lysine binding modules. We conducted a systematic structural analysis of readers of methyl marks and derived a predictive druggability landscape of methyl-lysine binding modules. We show that these target classes are generally less druggable than bromodomains, but that some proteins stand as notable exceptions.

  7. Optical aptasensors for quantitative detection of small biomolecules: a review.

    PubMed

    Feng, Chunjing; Dai, Shuang; Wang, Lei

    2014-09-15

    Aptasensors are aptamer-based biosensors with excellent recognition capability towards a wide range of targets. Specially, there have been ever-growing interests in the development of aptasensors for the detection of small molecules. This phenomenon is contributed to two reasons. On one hand, small biomolecules play an important role in living organisms with many kinds of biological function, such as antiarrhythmic effect and vasodilator activity of adenosine. On the other hand, the concentration of small molecules can be an indicator for disease diagnosis, for example, the concentration of ATP is closely associated with cell injury and cell viability. As a potential analysis tool in the construction of aptasensors, optical analysis has attracted much more interest of researchers due to its high sensitivity, quick response and simple operation. Besides, it promises the promotion of aptasensors in performance toward a new level. Review the development of optical aptasensors for small biomolecules will give readers an overall understanding of its progress and provide some theoretical guidelines for its future development. Hence, we give a mini-review on the advance of optical aptasensors for small biomolecules. This review focuses on recent achievements in the design of various optical aptasensors for small biomolecules, containing fluorescence aptasensors, colorimetric aptasensors, chemiluminescence aptasensors and other optical aptasensors. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Wavefront holoscopy: application of digital in-line holography for the inspection of engraved marks in progressive addition lenses.

    PubMed

    Perucho, Beatriz; Micó, Vicente

    2014-01-01

    Progressive addition lenses (PALs) are engraved with permanent marks at standardized locations in order to guarantee correct centering and alignment throughout the manufacturing and mounting processes. Out of the production line, engraved marks provide useful information about the PAL as well as act as locator marks to re-ink again the removable marks. Even though those marks should be visible by simple visual inspection with the naked eye, engraving marks are often faint and weak, obscured by scratches, and partially occluded and difficult to recognize on tinted or antireflection-coated lenses. Here, we present an extremely simple optical device (named as wavefront holoscope) for visualization and characterization of permanent marks in PAL based on digital in-line holography. Essentially, a point source of coherent light illuminates the engraved mark placed just before a CCD camera that records a classical Gabor in-line hologram. The recorded hologram is then digitally processed to provide a set of high-contrast images of the engraved marks. Experimental results are presented showing the applicability of the proposed method as a new ophthalmic instrument for visualization and characterization of engraved marks in PALs.

  9. High-bandwidth generation of duobinary and alternate-mark-inversion modulation formats using SOA-based signal processing.

    PubMed

    Dailey, James M; Power, Mark J; Webb, Roderick P; Manning, Robert J

    2011-12-19

    We report on the novel all-optical generation of duobinary (DB) and alternate-mark-inversion (AMI) modulation formats at 42.6 Gb/s from an input on-off keyed signal. The modulation converter consists of two semiconductor optical amplifier (SOA)-based Mach-Zehnder interferometer gates. A detailed SOA model numerically confirms the operational principles and experimental data shows successful AMI and DB conversion at 42.6 Gb/s. We also predict that the operational bandwidth can be extended beyond 40 Gb/s by utilizing a new pattern-effect suppression scheme, and demonstrate dramatic reductions in patterning up to 160 Gb/s. We show an increasing trade-off between pattern-effect reduction and mean output power with increasing bitrate.

  10. Impact of anatomical parameters on optical coherence tomography retinal nerve fiber layer thickness abnormality patterns

    NASA Astrophysics Data System (ADS)

    Baniasadi, Neda; Wang, Mengyu; Wang, Hui; Jin, Qingying; Mahd, Mufeed; Elze, Tobias

    2017-02-01

    Purpose: To evaluate the effects of four anatomical parameters (angle between superior and inferior temporal retinal arteries [inter-artery angle, IAA], optic disc [OD] rotation, retinal curvature, and central retinal vessel trunk entry point location [CRVTL]) on retinal nerve fiber layer thickness (RNFLT) abnormality marks by OCT machines. Methods: Cirrus OCT circumpapillary RNFLT measurements and Humphrey visual fields (HVF 24-2) of 421 patients from a large glaucoma clinic were included. Ellipses were fitted to the OD borders. Ellipse rotation relative to the vertical axis defined OD rotation. CRVTL was manually marked on the horizontal axis of the ellipse on the OCT fundus image. IAA was calculated between manually marked retinal artery locations at the 1.73mm radius around OD. Retinal curvature was determined by the inner limiting membrane on the horizontal B-scan closest to the OD center. For each location on the circumpapillary scanning area, logistic regression was used to determine if each of the four parameters had a significant impact on RNFLT abnormality marks independent of disease severity. The results are presented on spatial maps of the entire scanning area. Results: Variations in IAA significantly influenced abnormality marks on 38.8% of the total scanning area, followed by CRVTL (19.2%) and retinal curvature (18.7%). The effect of OD rotation was negligible (<1%). Conclusions: A natural variation in IAA, retinal curvature, and CRVTL can affect OCT abnormality ratings, which may bias clinical diagnosis. Our spatial maps may help OCT manufacturers to introduce location specific norms to ensure that abnormality marks indicate ocular disease instead of variations in eye anatomy.

  11. Enhacement of intrafield overlay using a design based metrology system

    NASA Astrophysics Data System (ADS)

    Jo, Gyoyeon; Ji, Sunkeun; Kim, Shinyoung; Kang, Hyunwoo; Park, Minwoo; Kim, Sangwoo; Kim, Jungchan; Park, Chanha; Yang, Hyunjo; Maruyama, Kotaro; Park, Byungjun

    2016-03-01

    As the scales of the semiconductor devices continue to shrink, accurate measurement and control of the overlay have been emphasized for securing more overlay margin. Conventional overlay analysis methods are based on the optical measurement of the overlay mark. However, the overlay data obtained from these optical methods cannot represent the exact misregistration between two layers at the circuit level. The overlay mismatch may arise from the size or pitch difference between the overlay mark and the real pattern. Pattern distortion, caused by CMP or etching, could be a source of the overlay mismatch as well. Another issue is the overlay variation in the real circuit pattern which varies depending on its location. The optical overlay measurement methods, such as IBO and DBO that use overlay mark on the scribeline, are not capable of defining the exact overlay values of the real circuit. Therefore, the overlay values of the real circuit need to be extracted to integrate the semiconductor device properly. The circuit level overlay measurement using CDSEM is time-consuming in extracting enough data to indicate overall trend of the chip. However DBM tool is able to derive sufficient data to display overlay tendency of the real circuit region with high repeatability. An E-beam based DBM(Design Based Metrology) tool can be an alternative overlay measurement method. In this paper, we are going to certify that the overlay values extracted from optical measurement cannot represent the circuit level overlay values. We will also demonstrate the possibility to correct misregistration between two layers using the overlay data obtained from the DBM system.

  12. Explorers of the Southern Sky: A History of Australian Astronomy

    NASA Astrophysics Data System (ADS)

    Haynes, Raymond; Haynes, Roslynn D.; Malin, David; McGee, Richard

    1996-06-01

    This well-illustrated volume is the most comprehensive account of Australian astronomy to date. It is both an indispensable reference book on the history of astronomy in Australia, and a highly readable study of a scientific discipline in the context of emerging nationhood. It covers not only the science, but the individuals involved and the social and economic climate in which they worked. Starting from the ancient Aboriginal beliefs about the Sky World - the earliest known astronomy, anywhere in the world - we are led through to the most exciting high-tech current and projected research being carried out at Australia's world-class national astronomy facilities, and by groups in Australian universities. All branches of astronomy are covered - optical, infrared, X-ray, gamma-ray, microwave, gravitational wave and theoretical - including the contribution of amateur astronomers. The non-technical language, many illustrations, and explanatory figures, ensure that this guide will appeal to a wide range of readers - including professional astronomers, historians of science, students, amateur astronomers and general readers.

  13. EDITORIAL: Squeeze transformation and optics after Einstein

    NASA Astrophysics Data System (ADS)

    Kim, Young S.; Man'ko, Margarita A.; Planat, Michel

    2005-12-01

    With this special issue, Journal of Optics B: Quantum and Semiclassical Optics contributes to the celebration of the World Year of Physics held in recognition of five brilliant papers written by Albert Einstein in 1905. There is no need to explain to the readers of this journal the content and importance of these papers, which are cornerstones of modern physics. The 51 contributions in this special issue represent current trends in quantum optics —100 years after the concept of light quanta was introduced. At first glance, in his famous papers of 1905, Einstein treated quite independent subjects—special relativity, the nature and statistical properties of light, electrodynamics of moving bodies and Brownian motion. We now know that all these phenomena are deeply related, and these relations are clearly shown in many papers in this issue. Most of the papers are based on the talks and poster contributions from participants of the 9th International Conference on Squeezed States and Uncertainty Relations (ICSSUR'05), which took place in Besançon, France, 2-6 May, 2005. This was the continuation of a series of meetings, originating with the first workshops organized by Professor Y S Kim at the University of Maryland, College Park, USA, in 1991 and by Professor V I Man'ko at the Lebedev Physical Institute, Moscow in 1992. One of the main topics of ICSSUR'05 and this special issue is the theory and applications of squeezed states and their generalizations. At first glance, one could think that this subject has no relation to Einstein's papers. However, this is not true: the theory of squeezed states is deeply related to special relativity, as far as it is based on the representations of the Lorentz group (see the paper by Kim Y S and Noz M E, S458-S467), which also links the current concepts of entanglement and decoherence with Lorentz-covariance. Besides, studies of the different quantum states of light imply, after all, the study of photon (or photo-electron) statistics and fluctuations of the electromagnetic field, whose importance was first emphasized by Einstein in 1905. The squeezed states can also be considered as a generalization of the concept of coherent states, which turned out to be one of the most important theoretical tools for solving the numerous problems of quantum optics. It seems highly symbolical that the printed version of this special issue will appear in the same month when one of the prominent creators of the theory of coherent states and modern quantum optics—Professor Roy J Glauber—will receive his Nobel Prize in Stockholm. ICSSUR'05 was opened by the invited talk of R J Glauber, `What makes a quantum jump?', and we take great pleasure in congratulating him on this well deserved award. We are sure that all participants of ICSSUR'05 and all readers of this special issue share our feelings. Two other Nobel Prize winners of 2005—Professor J L Hall and Professor T W H\\"ansch—also made great contributions to quantum optics. In particular, in 1986, J L Hall with collaborators, performed the first experiments on the generation of squeezed states by parametric down conversion, having obtained squeezing at the 50% level (Wu L A, Kimble H J, Hall J L and Wu H 1986 Phys. Rev. Lett. 57 2520). Another area, which has attracted the attention of many researchers in the past decade and which is well represented in this special issue, is related to the problems of quantum correlations, entanglement and quantum nonlocality. It is also connected with the name of Einstein due to his famous `EPR' paper of 1935 written together with Podolsky and Rosen. For several decades this was an area of `thought experiments' only, but now this field is becoming a new part of physics, known as `quantum information'. The reader can find several papers which introduce new concepts in this area, such as applications of the Galois algebras and discrete Wigner functions. Solutions of different problems of the interaction between light and matter (which also take their origin in Einstein's paper of 1905), stationary and nonstationary Casimir effect, decoherence, new forms of uncertainty relations and their experimental verification, etc, can also be found in this issue. Many other contributions will be published in another special issue of the International Journal of Modern Physics B entitled `Quantum Information in Modern Optics'. This special issue is also the last issue of Journal of Optics B: Quantum and Semiclassical Optics. For the past 15 years this journal and its predecessors—Quantum Optics and Quantum and Semiclassical Optics—gained great respect among the quantum optics community. Many breakthrough papers were published in its pages during this period (see, for example, Schrade G, Man'ko V I, Schleich W P and Glauber R J 1995 Wigner Functions in the Paul trap Quantum Semiclass. Opt. 7 307). Since 1999, Journal of Optics B: Quantum and Semiclassical Optics has published a special issue for each ICSSUR meeting. This is the fourth issue of this series. We would like to thank Institute of Physics Publishing and the staff of Journal of Optics B: Quantum and Semiclassical Optics for providing the opportunity to pursue this programme, hoping that such a cooperation will continue in the future. We would also like to thank the many colleagues, who served as referees and whose efforts helped immensely in the preparation of this issue at such a high standard. The 10th ICSSUR conference will be organized for 2007 in Bradford, UK, by Professor A Vourdas. We invite readers to join us in two years.

  14. The Role of Histone Protein Modifications and Mutations in Histone Modifiers in Pediatric B-Cell Progenitor Acute Lymphoblastic Leukemia

    PubMed Central

    Janczar, Szymon; Janczar, Karolina; Pastorczak, Agata; Harb, Hani; Paige, Adam J. W.; Zalewska-Szewczyk, Beata; Danilewicz, Marian; Mlynarski, Wojciech

    2017-01-01

    While cancer has been long recognized as a disease of the genome, the importance of epigenetic mechanisms in neoplasia was acknowledged more recently. The most active epigenetic marks are DNA methylation and histone protein modifications and they are involved in basic biological phenomena in every cell. Their role in tumorigenesis is stressed by recent unbiased large-scale studies providing evidence that several epigenetic modifiers are recurrently mutated or frequently dysregulated in multiple cancers. The interest in epigenetic marks is especially due to the fact that they are potentially reversible and thus druggable. In B-cell progenitor acute lymphoblastic leukemia (BCP-ALL) there is a relative paucity of reports on the role of histone protein modifications (acetylation, methylation, phosphorylation) as compared to acute myeloid leukemia, T-cell ALL, or other hematologic cancers, and in this setting chromatin modifications are relatively less well studied and reviewed than DNA methylation. In this paper, we discuss the biomarker associations and evidence for a driver role of dysregulated global and loci-specific histone marks, as well as mutations in epigenetic modifiers in BCP-ALL. Examples of chromatin modifiers recurrently mutated/disrupted in BCP-ALL and associated with disease outcomes include MLL1, CREBBP, NSD2, and SETD2. Altered histone marks and histone modifiers and readers may play a particular role in disease chemoresistance and relapse. We also suggest that epigenetic regulation of B-cell differentiation may have parallel roles in leukemogenesis. PMID:28054944

  15. Overview of Photonic Materials for Application in Space Environments

    NASA Technical Reports Server (NTRS)

    Taylor, E. W.; Osinski, M.; Svimonishvili, Tengiz; Watson, M.; Bunton, P.; Pearson, S. D.; Bilbro, J.

    1999-01-01

    Future space systems will he based on components evolving from the development and refinement of new and existing photonic materials. Optically based sensors, inertial guidance, tracking systems, communications, diagnostics, imaging and high speed optical processing are but a few of the applications expected to widely utilize photonic materials. The response of these materials to space environment effects (SEE) such as spacecraft charging, orbital debris, atomic oxygen, ultraviolet irradiation, temperature and ionizing radiation will be paramount to ensuring successful space applications. The intent of this paper is to, address the latter two environments via a succinct comparison of the known sensitivities of selected photonic materials to the temperature and ionizing radiation conditions found in space and enhanced space environments Delineation of the known temperature and radiation induced responses in LiNbO3, AlGaN, AlGsAs,TeO2, Si:Ge, and several organic polymers are presented. Photonic materials are realizing rapid transition into applications for many proposed space components and systems including: optical interconnects, optical gyros, waveguide and spatial light modulators, light emitting diodes, lasers, optical fibers and fiber optic amplifiers. Changes to material parameters such as electrooptic coefficients, absorption coefficients, polarization, conductivity, coupling coefficients, diffraction efficiencies, and other pertinent material properties examined for thermo-optic and radiation induced effect. Conclusions and recommendations provide the reader with an understanding of the limitations or attributes of material choices for specific applications.

  16. Designing a freeform optic for oblique illumination

    NASA Astrophysics Data System (ADS)

    Uthoff, Ross D.; Ulanch, Rachel N.; Williams, Kaitlyn E.; Ruiz Diaz, Liliana; King, Page; Koshel, R. John

    2017-11-01

    The Functional Freeform Fitting (F4) method is utilized to design a freeform optic for oblique illumination of Mark Rothko's Green on Blue (1956). Shown are preliminary results from an iterative freeform design process; from problem definition and specification development to surface fit, ray tracing results, and optimization. This method is applicable to both point and extended sources of various geometries.

  17. Hybrid Piezoelectric/Fiber-Optic Sensor Sheets

    NASA Technical Reports Server (NTRS)

    Lin, Mark; Qing, Xinlin

    2004-01-01

    Hybrid piezoelectric/fiber-optic (HyPFO) sensor sheets are undergoing development. They are intended for use in nondestructive evaluation and long-term monitoring of the integrity of diverse structures, including aerospace, aeronautical, automotive, and large stationary ones. It is anticipated that the further development and subsequent commercialization of the HyPFO sensor systems will lead to economic benefits in the form of increased safety, reduction of life-cycle costs through real-time structural monitoring, increased structural reliability, reduction of maintenance costs, and increased readiness for service. The concept of a HyPFO sensor sheet is a generalization of the concept of a SMART Layer(TradeMark), which is a patented device that comprises a thin dielectric film containing an embedded network of distributed piezoelectric actuator/sensors. Such a device can be mounted on the surface of a metallic structure or embedded inside a composite-material structure during fabrication of the structure. There is has been substantial interest in incorporating sensors other than piezoelectric ones into SMART Layer(TradeMark) networks: in particular, because of the popularity of the use of fiber-optic sensors for monitoring the "health" of structures in recent years, it was decided to incorporate fiber-optic sensors, giving rise to the concept of HyPFO devices.

  18. Optical diagnostics in the oral cavity: an overview.

    PubMed

    Wilder-Smith, P; Holtzman, J; Epstein, J; Le, A

    2010-11-01

    As the emphasis shifts from damage mitigation to disease prevention or reversal of early disease in the oral cavity, the need for sensitive and accurate detection and diagnostic tools become more important. Many novel and emergent optical diagnostic modalities for the oral cavity are becoming available to clinicians with a variety of desirable attributes including: (i) non-invasiveness, (ii) absence of ionizing radiation, (iii) patient-friendliness, (iv) real-time information (v) repeatability, and (vi) high-resolution surface and subsurface images. In this article, the principles behind optical diagnostic approaches, their feasibility and applicability for imaging soft and hard tissues, and their potential usefulness as a tool in the diagnosis of oral mucosal lesions, dental pathologies, and other dental applications will be reviewed. The clinical applications of light-based imaging technologies in the oral cavity and of their derivative devices will be discussed to provide the reader with a comprehensive understanding of emergent diagnostic modalities. © 2010 John Wiley & Sons A/S.

  19. Optic nerve head biomechanics in aging and disease.

    PubMed

    Downs, J Crawford

    2015-04-01

    This nontechnical review is focused upon educating the reader on optic nerve head biomechanics in both aging and disease along two main themes: what is known about how mechanical forces and the resulting deformations are distributed in the posterior pole and ONH (biomechanics) and what is known about how the living system responds to those deformations (mechanobiology). We focus on how ONH responds to IOP elevations as a structural system, insofar as the acute mechanical response of the lamina cribrosa is confounded with the responses of the peripapillary sclera, prelaminar neural tissues, and retrolaminar optic nerve. We discuss the biomechanical basis for IOP-driven changes in connective tissues, blood flow, and cellular responses. We use glaucoma as the primary framework to present the important aspects of ONH biomechanics in aging and disease, as ONH biomechanics, aging, and the posterior pole extracellular matrix (ECM) are thought to be centrally involved in glaucoma susceptibility, onset and progression. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Gold Nanoparticles in Photonic Crystals Applications: A Review

    PubMed Central

    Venditti, Iole

    2017-01-01

    This review concerns the recently emerged class of composite colloidal photonic crystals (PCs), in which gold nanoparticles (AuNPs) are included in the photonic structure. The use of composites allows achieving a strong modification of the optical properties of photonic crystals by involving the light scattering with electronic excitations of the gold component (surface plasmon resonance, SPR) realizing a combination of absorption bands with the diffraction resonances occurring in the body of the photonic crystals. Considering different preparations of composite plasmonic-photonic crystals, based on 3D-PCs in presence of AuNPs, different resonance phenomena determine the optical response of hybrid crystals leading to a broadly tunable functionality of these crystals. Several chemical methods for fabrication of opals and inverse opals are presented together with preparations of composites plasmonic-photonic crystals: the influence of SPR on the optical properties of PCs is also discussed. Main applications of this new class of composite materials are illustrated with the aim to offer the reader an overview of the recent advances in this field. PMID:28772458

  1. Investigation of organic solvents assisted nano magnesium oxide nanoparticles and their structural, morphological, optical and antimicrobial performance

    NASA Astrophysics Data System (ADS)

    Deepa, B.; Rajendran, V.

    2018-01-01

    Investigation on the structural, morphological, optical studies and antimicrobial performance of organic solvent assisted magnesium oxide (MgO) nanoparticles. Nanoparticles are in 16-18 nm of grain size prepared by sol-gel method. The XRD studies shows as synthesized products are in cubic phase with periclase structurer. The well disperesd spherical morphology were obtained in SEM and TEM. The organic solvent methanol had profound effects on the size of the nano particles. The optical absorption edge energy was present in UV region and the corresponding band gap energy values are 4.5 and 4.9 eV for water with ethanol and methanol mediated MgO sample respectively. The PL emission spectrum has a emission peak at 340 and 353 nm which is due to surface defects. The obtained MgO nanoparticles showed superior antimicrobial activities for the gram positive, gram negative and fungus strains using the ELISA reader at 450 nm.

  2. Gold Nanoparticles in Photonic Crystals Applications: A Review.

    PubMed

    Venditti, Iole

    2017-01-24

    This review concerns the recently emerged class of composite colloidal photonic crystals (PCs), in which gold nanoparticles (AuNPs) are included in the photonic structure. The use of composites allows achieving a strong modification of the optical properties of photonic crystals by involving the light scattering with electronic excitations of the gold component (surface plasmon resonance, SPR) realizing a combination of absorption bands with the diffraction resonances occurring in the body of the photonic crystals. Considering different preparations of composite plasmonic-photonic crystals, based on 3D-PCs in presence of AuNPs, different resonance phenomena determine the optical response of hybrid crystals leading to a broadly tunable functionality of these crystals. Several chemical methods for fabrication of opals and inverse opals are presented together with preparations of composites plasmonic-photonic crystals: the influence of SPR on the optical properties of PCs is also discussed. Main applications of this new class of composite materials are illustrated with the aim to offer the reader an overview of the recent advances in this field.

  3. Enhancing Soundtracks From Old Movies

    NASA Technical Reports Server (NTRS)

    Frazer, Robert E.

    1992-01-01

    Proposed system enhances soundtracks of old movies. Signal on optical soundtrack of film digitized and processed to reduce noise and improve quality; timing signals added, and signal recorded on compact disk. Digital comparator and voltage-controlled oscillator synchronizes speed of film-drive motor and compact disk motor. Frame-coded detector reads binary frame-identifying marks on film. Digital comparator generates error signal if marks on film do not match those on compact disk.

  4. An optical authentication system based on imaging of excitation-selected lanthanide luminescence.

    PubMed

    Carro-Temboury, Miguel R; Arppe, Riikka; Vosch, Tom; Sørensen, Thomas Just

    2018-01-01

    Secure data encryption relies heavily on one-way functions, and copy protection relies on features that are difficult to reproduce. We present an optical authentication system based on lanthanide luminescence from physical one-way functions or physical unclonable functions (PUFs). They cannot be reproduced and thus enable unbreakable encryption. Further, PUFs will prevent counterfeiting if tags with unique PUFs are grafted onto products. We have developed an authentication system that comprises a hardware reader, image analysis, and authentication software and physical keys that we demonstrate as an anticounterfeiting system. The physical keys are PUFs made from random patterns of taggants in polymer films on glass that can be imaged following selected excitation of particular lanthanide(III) ions doped into the individual taggants. This form of excitation-selected imaging ensures that by using at least two lanthanide(III) ion dopants, the random patterns cannot be copied, because the excitation selection will fail when using any other emitter. With the developed reader and software, the random patterns are read and digitized, which allows a digital pattern to be stored. This digital pattern or digital key can be used to authenticate the physical key in anticounterfeiting or to encrypt any message. The PUF key was produced with a staggering nominal encoding capacity of 7 3600 . Although the encoding capacity of the realized authentication system reduces to 6 × 10 104 , it is more than sufficient to completely preclude counterfeiting of products.

  5. Severe optic neuritis in infectious mononucleosis.

    PubMed

    Jones, J; Gardner, W; Newman, T

    1988-04-01

    Because the presentation and clinical features of infectious mononucleosis can be misleading in the elderly, a significant number of infections may go unrecognized. We report an unusual case of infectious mononucleosis in a 61-year-old man in whom marked visual impairment was the presenting complaint and severe optic neuritis was the only prominent finding. Confirmation of the diagnosis was made by serologic testing for Epstein-Barr virus antibody. Recovery of visual function was near complete, but optic atrophy persisted. We reviewed the English literature and collected seven cases of well-documented optic neuritis associated with infectious mononucleosis. A clinical profile of parainfectious optic neuritis is discussed along with the likely pathogenesis for this complication.

  6. Active marks structure optimization for optical-electronic systems of spatial position control of industrial objects

    NASA Astrophysics Data System (ADS)

    Sycheva, Elena A.; Vasilev, Aleksandr S.; Lashmanov, Oleg U.; Korotaev, Valery V.

    2017-06-01

    The article is devoted to the optimization of optoelectronic systems of the spatial position of objects. Probabilistic characteristics of the detection of an active structured mark on a random noisy background are investigated. The developed computer model and the results of the study allow us to estimate the probabilistic characteristics of detection of a complex structured mark on a random gradient background, and estimate the error of spatial coordinates. The results of the study make it possible to improve the accuracy of measuring the coordinates of the object. Based on the research recommendations are given on the choice of parameters of the optimal mark structure for use in opticalelectronic systems for monitoring the spatial position of large-sized structures.

  7. Reading Center Characterization of Central Retinal Vein Occlusion Using Optical Coherence Tomography During the COPERNICUS Trial.

    PubMed

    Decroos, Francis Char; Stinnett, Sandra S; Heydary, Cynthia S; Burns, Russell E; Jaffe, Glenn J

    2013-11-01

    To determine the impact of segmentation error correction and precision of standardized grading of time domain optical coherence tomography (OCT) scans obtained during an interventional study for macular edema secondary to central retinal vein occlusion (CRVO). A reading center team of two readers and a senior reader evaluated 1199 OCT scans. Manual segmentation error correction (SEC) was performed. The frequency of SEC, resulting change in central retinal thickness after SEC, and reproducibility of SEC were quantified. Optical coherence tomography characteristics associated with the need for SECs were determined. Reading center teams graded all scans, and the reproducibility of this evaluation for scan quality at the fovea and cystoid macular edema was determined on 97 scans. Segmentation errors were observed in 360 (30.0%) scans, of which 312 were interpretable. On these 312 scans, the mean machine-generated central subfield thickness (CST) was 507.4 ± 208.5 μm compared to 583.0 ± 266.2 μm after SEC. Segmentation error correction resulted in a mean absolute CST correction of 81.3 ± 162.0 μm from baseline uncorrected CST. Segmentation error correction was highly reproducible (intraclass correlation coefficient [ICC] = 0.99-1.00). Epiretinal membrane (odds ratio [OR] = 2.3, P < 0.0001), subretinal fluid (OR = 2.1, P = 0.0005), and increasing CST (OR = 1.6 per 100-μm increase, P < 0.001) were associated with need for SEC. Reading center teams reproducibly graded scan quality at the fovea (87% agreement, kappa = 0.64, 95% confidence interval [CI] 0.45-0.82) and cystoid macular edema (92% agreement, kappa = 0.84, 95% CI 0.74-0.94). Optical coherence tomography images obtained during an interventional CRVO treatment trial can be reproducibly graded. Segmentation errors can cause clinically meaningful deviation in central retinal thickness measurements; however, these errors can be corrected reproducibly in a reading center setting. Segmentation errors are common on these images, can cause clinically meaningful errors in central retinal thickness measurement, and can be corrected reproducibly in a reading center setting.

  8. [Functional state of vision system under chronic mercury intoxication].

    PubMed

    Iablonskaia, D A; Mishchenko, T S; Lakhman, O L; Rukavishnikov, V S; Malyshev, V V

    2010-01-01

    Examination of chronic mercury intoxication patients in distant (post-contact) period revealed marked vision disorders and inhibited neuro-conductivity--inhibited neuronal structures of retina and optic nerve.

  9. Au doping effects on electrical and optical properties of vanadium dioxides

    NASA Astrophysics Data System (ADS)

    Zhu, YaBin; He, Fan; Na, Jie

    2012-03-01

    Vanadium dioxides were fabricated on normal glass substrates using reactive radio frequency (RF) magnetron sputtering. The oxygen flow volume and annealed temperatures as growth parameters are systematically investigated. The electrical and optical properties of VO2 and Au:VO2 thin films with different growth conditions are discussed. The semiconductor-metal phase transition temperature decreased by ˜10°C for the sample with Au doping compared to the sample without Au doping. However, the optical transmittance of Au:VO2 thin films is much lower than that of bare VO2. These results show that Au doping has a marked effect on the electrical and optical properties.

  10. Fiction: Simulation of Social Worlds.

    PubMed

    Oatley, Keith

    2016-08-01

    Fiction is the simulation of selves in interaction. People who read it improve their understanding of others. This effect is especially marked with literary fiction, which also enables people to change themselves. These effects are due partly to the process of engagement in stories, which includes making inferences and becoming emotionally involved, and partly to the contents of fiction, which include complex characters and circumstances that we might not encounter in daily life. Fiction can be thought of as a form of consciousness of selves and others that can be passed from an author to a reader or spectator, and can be internalized to augment everyday cognition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. ULTOR(Registered TradeMark) Passive Pose and Position Engine For Spacecraft Relative Navigation

    NASA Technical Reports Server (NTRS)

    Hannah, S. Joel

    2008-01-01

    The ULTOR(Registered TradeMark) Passive Pose and Position Engine (P3E) technology, developed by Advanced Optical Systems, Inc (AOS), uses real-time image correlation to provide relative position and pose data for spacecraft guidance, navigation, and control. Potential data sources include a wide variety of sensors, including visible and infrared cameras. ULTOR(Registered TradeMark) P3E has been demonstrated on a number of host processing platforms. NASA is integrating ULTOR(Registerd TradeMark) P3E into its Relative Navigation System (RNS), which is being developed for the upcoming Hubble Space Telescope (HST) Servicing Mission 4 (SM4). During SM4 ULTOR(Registered TradeMark) P3E will perform realtime pose and position measurements during both the approach and departure phases of the mission. This paper describes the RNS implementation of ULTOR(Registered TradeMark) P3E, and presents results from NASA's hardware-in-the-loop simulation testing against the HST mockup.

  12. A Morphological and Morphometric Study of Bite Marks Caused by Mice (Mus Musculus) on Different Baits for Forensic Purposes.

    PubMed

    Toledo, Víctor A; Fonseca, Gabriel M; González, Paula A; Ibarra, Luis; Torres, Francisco J; Sáez, Pedro L

    2017-03-01

    In animal bites, the dental attributes can be fundamental in identifying the marks made by various species on different matrices. Although rodent bite marks have been studied in the context of postmortem interference, little research has used different baits to analyze these marks linking not only specific behavior patterns but also the possibility of structural damage. Twenty mice (Mus musculus) were exposed to different baits to study their bite marks in a controlled model. The known pattern of parallel and multiple grooves has been seen in all baits, but polyvinyl chloride and fiber-optic cable were significantly different between each other and the other baits. Some baits showed patterns of anchorage of the upper incisors and space between the lower incisors when gnawing. This technical note represents a novel model of analysis where veterinarians and/or dentists may be asked to give an opinion on alleged animal bite marks. © 2016 American Academy of Forensic Sciences.

  13. Multiple-stage pure phase encoding with biometric information

    NASA Astrophysics Data System (ADS)

    Chen, Wen

    2018-01-01

    In recent years, many optical systems have been developed for securing information, and optical encryption/encoding has attracted more and more attention due to the marked advantages, such as parallel processing and multiple-dimensional characteristics. In this paper, an optical security method is presented based on pure phase encoding with biometric information. Biometric information (such as fingerprint) is employed as security keys rather than plaintext used in conventional optical security systems, and multiple-stage phase-encoding-based optical systems are designed for generating several phase-only masks with biometric information. Subsequently, the extracted phase-only masks are further used in an optical setup for encoding an input image (i.e., plaintext). Numerical simulations are conducted to illustrate the validity, and the results demonstrate that high flexibility and high security can be achieved.

  14. Optical Storage Technology Subgroup (FIMUG)

    DTIC Science & Technology

    1990-04-01

    SECURITY CLASSICATON O NGRS PAG E NPAGE OMNo. 0704- 01 " I a REPORT SECUR - ,. ASSF o RiSTRICTIVE MARKINGS Unclasified oJU IS M’ 2a SECURITY C,.ASS...USERS 22a. NAME OF RESPONSIBLE INDIVIDUAL i22o TELEPHONE (include Area Code) 22c OFFICE SYMBOL (I 00 Form 1473, JUN 06 Previous e1t3onJ art obSo1te...Mdium May Change Shape of Optical Storage." PC Week. 1988 (21 Jun). "More Volume Buyers Turning Eyes Toward Optical-Storage Market." PC Week. 1988 (25 Jul

  15. Resident Information Management System of Shibuya

    NASA Astrophysics Data System (ADS)

    Kokubo, Shoji

    Inhabitant record image processing system using optical disks and LAN was introduced and has been at fully operational stage since March, 1985 at Shibuya Ward Office. Inhabitant forms which have been filled in by handwriting are recorded on the optical disks and retrieved when necessary so that inhabitant's moving-in and out business can be handled at any branch office, and waiting time for issuance of the inhabitant form is markedly reduced. The optical file system is outlined first, then the system outline at the Ward Office and its operation are described.

  16. Professor Igor Yevseyev: In Memoriam Professor Igor Yevseyev: In Memoriam

    NASA Astrophysics Data System (ADS)

    2012-06-01

    Dear readers and authors, June 3, 2012 will mark five months since Professor Igor Yevseyev, Deputy Editor-in-Chief of both journals Laser Physics and Laser Physics Letters passed away, suddenly and unexpectedly. He was 67. Born in Moscow, he entered one of the world's best schools of physics, Moscow Engineering Physics Institute (MEPhI). With this renowned educational and research institution he bonded an alliance for his entire life, starting as an undergraduate student in the Department of Theoretical Physics and later continued as graduate student, assistant professor, associated professor, and full professor in the same department, a rare accomplishment of a person. All those years he retained the love of his life—the love for physics. He worked tirelessly as a teacher and scholar in this captivating field of knowledge. Professor Yevseyev was one of the founders of the international journal of Laser Physics in 1990, the first academic English language journal published in the former USSR. Later, in 2004, the second journal, Laser Physics Letters was brought to the forum of global laser physics community. The idea behind this new title was Professor Yevseyev's initiative to reach the readers and participants with new pioneering and break-through research results more rapidly. His leadership and indefatigable dedication to the quality of published materials made it possible that this journal reached international recognition in a few short years. Still, in order to attract even more attention of potential contributors and readers, Professor Yevseyev originally proposed to conduct the International Laser Physics Workshop (LPHYS) on the annual basis. Since 1992 the Workshop has been conducted every year, each year in a different country. As in all previous years, Professor Yevseyev was the key organizer of this year's workshop in Calgary, Canada. Sadly, this workshop will take place without him. Editorial Board

  17. Digital tomosynthesis for evaluating metastatic lung nodules: nodule visibility, learning curves, and reading times.

    PubMed

    Lee, Kyung Hee; Goo, Jin Mo; Lee, Sang Min; Park, Chang Min; Bahn, Young Eun; Kim, Hyungjin; Song, Yong Sub; Hwang, Eui Jin

    2015-01-01

    To evaluate nodule visibility, learning curves, and reading times for digital tomosynthesis (DT). We included 80 patients who underwent computed tomography (CT) and DT before pulmonary metastasectomy. One experienced chest radiologist annotated all visible nodules on thin-section CT scans using computer-aided detection software. Two radiologists used CT as the reference standard and retrospectively graded the visibility of nodules on DT. Nodule detection performance was evaluated in four sessions of 20 cases each by six readers. After each session, readers were unblinded to the DT images by revealing the true-positive markings and were instructed to self-analyze their own misreads. Receiver-operating-characteristic curves were determined. Among 414 nodules on CT, 53.3% (221/414) were visible on DT. The main reason for not seeing a nodule on DT was small size (93.3%, ≤ 5 mm). DT revealed a substantial number of malignant nodules (84.1%, 143/170). The proportion of malignant nodules among visible nodules on DT was significantly higher (64.7%, 143/221) than that on CT (41.1%, 170/414) (p < 0.001). Area under the curve (AUC) values at the initial session were > 0.8, and the average detection rate for malignant nodules was 85% (210/246). The inter-session analysis of the AUC showed no significant differences among the readers, and the detection rate for malignant nodules did not differ across sessions. A slight improvement in reading times was observed. Most malignant nodules > 5 mm were visible on DT. As nodule detection performance was high from the initial session, DT may be readily applicable for radiology residents and board-certified radiologists.

  18. Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.

    PubMed

    Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C

    2016-06-01

    The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.

  19. Introduction to optical methods for characterizing liquid crystals at interfaces.

    PubMed

    Miller, Daniel S; Carlton, Rebecca J; Mushenheim, Peter C; Abbott, Nicholas L

    2013-03-12

    This Instructional Review describes methods and underlying principles that can be used to characterize both the orientations assumed spontaneously by liquid crystals (LCs) at interfaces and the strength with which the LCs are held in those orientations (so-called anchoring energies). The application of these methods to several different classes of LC interfaces is described, including solid and aqueous interfaces as well as planar and nonplanar interfaces (such as those that define a LC-in-water emulsion droplet). These methods, which enable fundamental studies of the ordering of LCs at polymeric, chemically functionalized, and biomolecular interfaces, are described in this Instructional Review on a level that can be easily understood by a nonexpert reader such as an undergraduate or graduate student. We focus on optical methods because they are based on instrumentation that is found widely in research and teaching laboratories.

  20. Optical waveguides in lithium niobate: Recent developments and applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bazzan, Marco, E-mail: marco.bazzan@unipd.it; Sada, Cinzia, E-mail: cinzia.sada@unipd.it

    The state of the art of optical waveguide fabrication in lithium niobate is reviewed, with particular emphasis on new technologies and recent applications. The attention is mainly devoted to recently developed fabrication methods, such as femtosecond laser writing, ion implantation, and smart cut waveguides as well as to the realization of waveguides with tailored functionalities, such as photorefractive or domain engineered structures. More exotic systems, such as reconfigurable and photorefractive soliton waveguides, are also considered. Classical techniques, such as Ti in-diffusion and proton exchange, are cited and briefly reviewed as a reference standpoint to highlight the recent developments. In allmore » cases, the application-oriented point of view is preferred, in order to provide the reader with an up-to date panorama of the vast possibilities offered by lithium niobate to integrated photonics.« less

  1. Near-infrared optical imaging of nucleic acid nanocarriers in vivo.

    PubMed

    Rome, Claire; Gravier, Julien; Morille, Marie; Divita, Gilles; Bolcato-Bellemin, Anne-Laure; Josserand, Véronique; Coll, Jean-Luc

    2013-01-01

    Noninvasive, real-time optical imaging methods are well suited to follow the in vivo distribution of nucleic acid nanocarriers, their dissociation, and the resulting gene expression or inhibition. Indeed, most small animal imaging devices perform bioluminescence and fluorescence measurements without moving the animal, allowing a simple, rapid, and cost-effective method of investigation of several parameters at a time, in longitudinal experiments that can last for days or weeks.Here we help the reader in choosing adapted near-infrared (NIR) fluorophores or pairs of fluorophores for Förster resonance energy transfer assays, imaging of reporter genes, as well as nanocarriers for in vivo gene and siRNA delivery. In addition, we present the labeling methods of these macromolecules and of their payload and the protocols to detect them using bioluminescence and NIR fluorescence imaging in mice.

  2. Near-infrared optical imaging of nucleic acid nanocarriers in vivo

    PubMed Central

    Rome, Claire; Gravier, Julien; Morille, Marie; Divita, Gilles; Bolcato-Bellemin, Anne-Laure; Josserand, Véronique; Coll, Jean-Luc

    2013-01-01

    Summary Non-invasive, real time optical imaging methods are particularly well suited for the in vivo follow up of the distribution of nucleic acids nanocarriers, their dissociation and finally the resulting gene expression or inhibition. Indeed, most small animal imaging devices are performing bioluminescence and fluorescence measurements without moving the animal, allowing a simple, rapid and cost effective method of investigation of several parameters at a time, in longitudinal experiments that can last for days or weeks. Here we propose to help the reader choosing adapted near-infrared (NIR) fluorophores or pairs of fluorophores for FRET assays, reporter genes as well as nanocarriers for in vivo gene and siRNA delivery. In addition, we present the labeling methods of these macromolecules, and of their payload and the protocols to detect them using bioluminescence and NIR fluorescence imaging in mice. PMID:23070763

  3. EDITORIAL: Award for Patrick Gill

    NASA Astrophysics Data System (ADS)

    Hauptmann, Peter

    2007-12-01

    On behalf of the journal I would like to congratulate Professor Patrick Gill, a long-serving member of the Editorial Board for Measurement Science and Technology, who has been awarded the prestigious Institute of Physics Young medal and prize for world-leading contributions to optical frequency metrology. He is recognized as the UK leader in the quest for very accurate optical clocks. Professor Gill's work is concerned with the development of cold trapped ion systems as optical frequency standards with potential for future redefinition of the SI second, and the frequency metrology needed to relate optical and microwave standards to high accuracy. Interested readers may wish to read a short review of the wider state-of-the-art development of single cold trapped ion frequency standards, coupled with a more detailed account of results achieved at the National Physical Laboratory, written by Professor Gill and co-workers from NPL: ''Trapped ion optical frequency standards'' by P Gill, G P Barwood, H A Klein, G Huang, S A Webster, P J Blythe, K Hosaka, S N Lea and H S Margolis 2003 Meas. Sci. Technol. 14 (8) 1174-86 He was one of the very early developers of the frequency comb idea, and in 2004 he led an experiment where the femtosecond laser frequency comb measured the prototype optical clock frequency, based on a strontium-ion optical transition, with accuracy close to the capability of the best caesium microwave clocks. Once again I congratulate Professor Gill and wish him every success for his future work.

  4. Sources of noise in magneto-optical readout

    NASA Technical Reports Server (NTRS)

    Mansuripur, M.

    1991-01-01

    The various sources of noise which are often encountered in magneto-optical readout systems are analyzed. Although the focus is on magneto-optics, most sources of noise are common among the various optical recording systems and one can easily adapt the results to other media and systems. A description of the magneto-optical readout system under consideration is given, and the standard methods and the relevant terminology of signal and noise measurement are described. The characteristics of thermal noise, which originates in the electronic circuitry of the readout system, are described. The most fundamental of all sources of noise, the shot noise, is considered, and a detailed account of its statistical properties is given. Shot noise, which is due to random fluctuations in photon arrival times, is an ever-present noise in optical detection. Since the performance of magneto-optical recording devices in use today is approaching the limit imposed by the shot noise, it is important that the reader have a good grasp of this particular source of noise. A model for the laser noise is described, and measurement results which yield numerical values for the strength of the laser power fluctuations are presented. Spatial variations of the disk reflectivity and random depolarization phenomena also contribute to the overall level of noise in readout; these and related issues are treated. Numerical simulation results describing some of the more frequently encountered sources of noise which accompany the recorded waveform itself, namely, jitter noise and signal-amplitude fluctuation noise are presented.

  5. Oxygen Plasma Modification of Poss-Coated Kapton(Registered TradeMark) HN Films

    NASA Technical Reports Server (NTRS)

    Wohl, C. J.; Belcher, M. A.; Ghose, S.; Connell, J. W.

    2008-01-01

    The surface energy of a material depends on both surface composition and topographic features. In an effort to modify the surface topography of Kapton(Registered TradeMark) HN film, organic solutions of a polyhedral oligomeric silsesquioxane, octakis(dimethylsilyloxy)silsesquioxane (POSS), were spray-coated onto the Kapton(Registered TradeMark) HN surface. Prior to POSS application, the Kapton(Registered TradeMark) HN film was activated by exposure to radio frequency (RF)-generated oxygen plasma. After POSS deposition and solvent evaporation, the films were exposed to various durations of RF-generated oxygen plasma to create a topographically rich surface. The modified films were characterized using optical microscopy, attenuated total reflection infrared (ATR-IR) spectroscopy, and high-resolution scanning electron microscopy (HRSEM). The physical properties of the modified films will be presented.

  6. The DCDC2/intron 2 deletion and white matter disorganization: focus on developmental dyslexia.

    PubMed

    Marino, Cecilia; Scifo, Paola; Della Rosa, Pasquale A; Mascheretti, Sara; Facoetti, Andrea; Lorusso, Maria L; Giorda, Roberto; Consonni, Monica; Falini, Andrea; Molteni, Massimo; Gruen, Jeffrey R; Perani, Daniela

    2014-08-01

    The DCDC2 gene is involved in neuronal migration. Heterotopias have been found within the white matter of DCDC2-knockdown rats. A deletion in DCDC2/intron 2 (DCDC2d), which encompasses a regulatory region named 'regulatory element associated with dyslexia 1' (READ1), increases the risk for dyslexia. We hypothesized that DCDC2d can be associated to alterations of the white matter structure in general and in dyslexic brains. Based on a full-factorial analysis of covariance (ANCOVA) model, we investigated voxel-based diffusion tensor imaging (VB-DTI) data of four groups of subjects: dyslexia with/without DCDC2d, and normal readers with/without DCDC2d. We also tested DCDC2d effects upon correlation patterns between fractional anisotropy (FA) and reading scores. We found that FA was reduced in the left arcuate fasciculus and splenium of the corpus callosum in subjects with versus without DCDC2d, irrespective of dyslexia. Subjects with dyslexia and DCDC2d showed reduced FA, mainly in the left hemisphere and in the corpus callosum; their counterpart without DCDC2d showed similar FA alterations. Noteworthy, a conjunction analysis in impaired readers revealed common regions with lower FA mainly in the left hemisphere. When we compared subjects with dyslexia with versus without DCDC2d, we found lower FA in the inferior longitudinal fasciculus and genu of the corpus callosum, bilaterally. Normal readers with versus without DCDC2d had FA increases and decreases in both the right and left hemisphere. The major contribution of our study was to provide evidence relating genes, brain and behaviour. Overall, our findings support the hypothesis that DCDC2d is associated with altered FA. In normal readers, DCDC2-related anatomical patterns may mark some developmental cognitive vulnerability to learning disabilities. In subjects with dyslexia, DCDC2d accounted for both common - mainly located in the left hemisphere - and unique - a more severe and extended pattern - alterations of white matter fibre tracts. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Readout-segmented multi-shot diffusion-weighted MRI of the knee joint in patients with juvenile idiopathic arthritis.

    PubMed

    Sauer, Alexander; Li, Mengxia; Holl-Wieden, Annette; Pabst, Thomas; Neubauer, Henning

    2017-10-12

    Diffusion-weighted MRI has been proposed as a new technique for imaging synovitis without intravenous contrast application. We investigated diagnostic utility of multi-shot readout-segmented diffusion-weighted MRI (multi-shot DWI) for synovial imaging of the knee joint in patients with juvenile idiopathic arthritis (JIA). Thirty-two consecutive patients with confirmed or suspected JIA (21 girls, median age 13 years) underwent routine 1.5 T MRI with contrast-enhanced T1w imaging (contrast-enhanced MRI) and with multi-shot DWI (RESOLVE, b-values 0-50 and 800 s/mm 2 ). Contrast-enhanced MRI, representing the diagnostic standard, and diffusion-weighted images at b = 800 s/mm 2 were separately rated by three independent blinded readers at different levels of expertise for the presence and the degree of synovitis on a modified 5-item Likert scale along with the level of subjective diagnostic confidence. Fourteen (44%) patients had active synovitis and joint effusion, nine (28%) patients showed mild synovial enhancement not qualifying for arthritis and another nine (28%) patients had no synovial signal alterations on contrast-enhanced imaging. Ratings by the 1st reader on contrast-enhanced MRI and on DWI showed substantial agreement (κ = 0.74). Inter-observer-agreement was high for diagnosing, or ruling out, active arthritis of the knee joint on contrast-enhanced MRI and on DWI, showing full agreement between 1st and 2nd reader and disagreement in one case (3%) between 1st and 3rd reader. In contrast, ratings in cases of absent vs. little synovial inflammation were markedly inconsistent on DWI. Diagnostic confidence was lower on DWI, compared to contrast-enhanced imaging. Multi-shot DWI of the knee joint is feasible in routine imaging and reliably diagnoses, or rules out, active arthritis of the knee joint in paediatric patients without the need of gadolinium-based i.v. contrast injection. Possibly due to "T2w shine-through" artifacts, DWI does not reliably differentiate non-inflamed joints from knee joints with mild synovial irritation.

  8. Laser Diode Pumped Solid State Lasers

    DTIC Science & Technology

    1987-01-01

    Report N66001-83-C-0071, 17 April 1986, prepared for NOSC. 4.6 W.T. Welford, R. Winston , "The Option of Nonimaging Concentrators ," Academic Press, 1978...by non-imac optics such as reflective or refractive flux concentrators . Simple considerations regarding the optimum pumping configuration, high marks...reduced if the arrays can stand-off from the Nd:YAG laser. As mentioned before, compound parabolic concentrators or refractive optics cat employed to

  9. All-optical lithography process for contacting nanometer precision donor devices

    NASA Astrophysics Data System (ADS)

    Ward, D. R.; Marshall, M. T.; Campbell, D. M.; Lu, T. M.; Koepke, J. C.; Scrymgeour, D. A.; Bussmann, E.; Misra, S.

    2017-11-01

    We describe an all-optical lithography process that can make electrical contact to nanometer-precision donor devices fabricated in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a patterned device establish the viability of the process.

  10. All-optical lithography process for contacting nanometer precision donor devices

    DOE PAGES

    Ward, Daniel Robert; Marshall, Michael Thomas; Campbell, DeAnna Marie; ...

    2017-11-06

    In this article, we describe an all-optical lithography process that can make electrical contact to nanometer-precision donor devices fabricated in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a patterned device establish the viability of the process.

  11. A Phenomenological Approach to Wear Debris Analysis

    DTIC Science & Technology

    1996-04-01

    Ferrography ; oil analysis; wear debris analysis Introduction: Wear debris analysis is an important subject in maintenance, especially condition...diagnostic ol can be traced to Ferrography developed in the early 1970’s. Westcott and Seifert [1] state e heart and soul of Ferrography , or optical debris...monitoring, as follows. The key to Ferrography or optical examination of wear debris is to find marks or features on wear debris which suggest likely

  12. All-optical lithography process for contacting nanometer precision donor devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, Daniel Robert; Marshall, Michael Thomas; Campbell, DeAnna Marie

    In this article, we describe an all-optical lithography process that can make electrical contact to nanometer-precision donor devices fabricated in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a patterned device establish the viability of the process.

  13. Wildlife contact rates at artificial feeding sites in Texas.

    PubMed

    Campbell, Tyler A; Long, David B; Shriner, Susan A

    2013-06-01

    Given the popularity of feeding white-tailed deer (Odocoileus virginianus) in Texas and the increasing amount of corn that is distributed, more information is needed on the impacts of this activity on non-target wildlife. Our objectives were to report visitation, intra- and interspecific contact, and contact rates of wildlife at artificial feeding sites in Texas. Our study was conducted at three sites in Kleberg and Nueces counties, Texas. We trapped animals from February to April and August to September, 2009 and marked animals with passive integrated transponder (PIT) tags. At each site and season, we placed one feeder system containing a PIT tag reader within 600 m of trap locations. Readers detected PIT tags from a distance of 25 cm. We determined a contact event to occur when two different PIT tags were detected by feeder systems within 5 s. We recorded 62,719 passes by raccoons (Procyon lotor), 103,512 passes by collared peccaries (Pecari tajacu), 2,923 passes by feral swine (Sus scrofa), 1,336 passes by fox squirrels (Sciurus niger), and no passes by opossums (Didelphis virginiana) at feeder systems. For site-season combinations in which contact events occurred, we found intraspecific contact rates (contacts per day) for raccoons, collared peccaries, and feral swine to be 0.81-124.77, 0.69-38.08, and 0.0-0.66, respectively. Throughout our study we distributed ~2,625 kg of whole kernel corn, which resulted in 6,351 contact events between marked wildlife (2.4 contacts per kg of corn). If 136 million kg of corn is distributed in Texas annually, we would expect >5.2 billion unnatural contact events between wildlife would result from this activity each year in Texas. Consequently, we do not believe that it is wise for natural resource managers to maintain artificial feeding sites for white-tailed deer or other wildlife due to pathogen transmission risks.

  14. Radio Frequency Identification (RFID) technology applied to the definition of underwater and subaerial coarse sediment movement

    NASA Astrophysics Data System (ADS)

    Bertoni, Duccio; Sarti, Giovanni; Benelli, Giuliano; Pozzebon, Alessandro; Raguseo, Gianluca

    2010-07-01

    In this paper, Radio Frequency Identification technology has been applied to track both underwater and subaerial displacement of pebbles along an artificial coarse beach at Marina di Pisa, Italy. Several preliminary laboratory tests have been performed to adapt the RFID technique for underwater use, which has been the primary impediment to this promising approach to the study of coarse sediment transport and movement. Tests showed the reliability of low frequencies for this kind of work, since they enable good signal transmission and reception through water. Passive ABS plastic transponders were inserted into about 100 pebbles and released onto the beach in March, 2009. A CORE-125 reader was chosen as the operating antenna to continuously transmit low frequency (125 kHz) signals. An acoustic signal toned whenever a pebble was detected while the unambiguous identification code of the pebble is shown immediately on the screen of a laptop connected to the reader. The positions of the pebbles were recorded with a total station. After two months (May, 2009), 74 marked pebbles were retrieved, 77% of the total. The positions of the retrieved pebbles were also recorded with the total station, thus allowing calculation of the coarse sediment transport tendency. About 60% of the recovered pebbles (44 out of 74) were found on the upper shoreface. The analysis of the marked pebble trajectories revealed a divergent transport movement in the northernmost sector of the beach. This movement was probably triggered by an irregularity of the submerged breakwater fronting the shoreline. The southern sector is characterised by chaotic pathways related to the formation and evolution of beach cusps. This outcome highlights and confirms the importance of a complete definition of the beach system, with no separation between the underwater and the subaerial portion of the shore when it comes to sediment transport and movement. This successful application of RFID technology to the underwater environment provides a chance to broaden understanding of a topic in need of further study.

  15. Wildlife Contact Rates at Artificial Feeding Sites in Texas

    NASA Astrophysics Data System (ADS)

    Campbell, Tyler A.; Long, David B.; Shriner, Susan A.

    2013-06-01

    Given the popularity of feeding white-tailed deer ( Odocoileus virginianus) in Texas and the increasing amount of corn that is distributed, more information is needed on the impacts of this activity on non-target wildlife. Our objectives were to report visitation, intra- and interspecific contact, and contact rates of wildlife at artificial feeding sites in Texas. Our study was conducted at three sites in Kleberg and Nueces counties, Texas. We trapped animals from February to April and August to September, 2009 and marked animals with passive integrated transponder (PIT) tags. At each site and season, we placed one feeder system containing a PIT tag reader within 600 m of trap locations. Readers detected PIT tags from a distance of 25 cm. We determined a contact event to occur when two different PIT tags were detected by feeder systems within 5 s. We recorded 62,719 passes by raccoons ( Procyon lotor), 103,512 passes by collared peccaries ( Pecari tajacu), 2,923 passes by feral swine ( Sus scrofa), 1,336 passes by fox squirrels ( Sciurus niger), and no passes by opossums ( Didelphis virginiana) at feeder systems. For site-season combinations in which contact events occurred, we found intraspecific contact rates (contacts per day) for raccoons, collared peccaries, and feral swine to be 0.81-124.77, 0.69-38.08, and 0.0-0.66, respectively. Throughout our study we distributed ~2,625 kg of whole kernel corn, which resulted in 6,351 contact events between marked wildlife (2.4 contacts per kg of corn). If 136 million kg of corn is distributed in Texas annually, we would expect >5.2 billion unnatural contact events between wildlife would result from this activity each year in Texas. Consequently, we do not believe that it is wise for natural resource managers to maintain artificial feeding sites for white-tailed deer or other wildlife due to pathogen transmission risks.

  16. Fully printed flexible and disposable wireless cyclic voltammetry tag.

    PubMed

    Jung, Younsu; Park, Hyejin; Park, Jin-Ah; Noh, Jinsoo; Choi, Yunchang; Jung, Minhoon; Jung, Kyunghwan; Pyo, Myungho; Chen, Kevin; Javey, Ali; Cho, Gyoujin

    2015-01-29

    A disposable cyclic voltammetry (CV) tag is printed on a plastic film by integrating wireless power transmitter, polarized triangle wave generator, electrochemical cell and signage through a scalable gravure printing method. By proximity of 13.56 MHz RF reader, the printed CV tag generates 320 mHz of triangular sweep wave from +500 mV to -500 mV which enable to scan a printed electrochemical cell in the CV tag. By simply dropping any specimen solution on the electrochemical cell in the CV tag, the presence of solutes in the solution can be detected and shown on the signage of the CV tag in five sec. 10 mM of N,N,N',N'-tetramethyl-p-phenylenediamine (TMPD) was used as a standard solute to prove the working concept of fully printed disposable wireless CV tag. Within five seconds, we can wirelessly diagnose the presence of TMPD in the solution using the CV tag in the proximity of the 13.56 MHz RF reader. This fully printed and wirelessly operated flexible CV tag is the first of its kind and marks the path for the utilization of inexpensive and disposable wireless electrochemical sensor systems for initial diagnose hazardous chemicals and biological molecules to improve public hygiene and health.

  17. Fully printed flexible and disposable wireless cyclic voltammetry tag

    PubMed Central

    Jung, Younsu; Park, Hyejin; Park, Jin-Ah; Noh, Jinsoo; Choi, Yunchang; Jung, Minhoon; Jung, Kyunghwan; Pyo, Myungho; Chen, Kevin; Javey, Ali; Cho, Gyoujin

    2015-01-01

    A disposable cyclic voltammetry (CV) tag is printed on a plastic film by integrating wireless power transmitter, polarized triangle wave generator, electrochemical cell and signage through a scalable gravure printing method. By proximity of 13.56 MHz RF reader, the printed CV tag generates 320 mHz of triangular sweep wave from +500 mV to −500 mV which enable to scan a printed electrochemical cell in the CV tag. By simply dropping any specimen solution on the electrochemical cell in the CV tag, the presence of solutes in the solution can be detected and shown on the signage of the CV tag in five sec. 10 mM of N,N,N′,N′-tetramethyl-p-phenylenediamine (TMPD) was used as a standard solute to prove the working concept of fully printed disposable wireless CV tag. Within five seconds, we can wirelessly diagnose the presence of TMPD in the solution using the CV tag in the proximity of the 13.56 MHz RF reader. This fully printed and wirelessly operated flexible CV tag is the first of its kind and marks the path for the utilization of inexpensive and disposable wireless electrochemical sensor systems for initial diagnose hazardous chemicals and biological molecules to improve public hygiene and health. PMID:25630250

  18. Fully printed flexible and disposable wireless cyclic voltammetry tag

    NASA Astrophysics Data System (ADS)

    Jung, Younsu; Park, Hyejin; Park, Jin-Ah; Noh, Jinsoo; Choi, Yunchang; Jung, Minhoon; Jung, Kyunghwan; Pyo, Myungho; Chen, Kevin; Javey, Ali; Cho, Gyoujin

    2015-01-01

    A disposable cyclic voltammetry (CV) tag is printed on a plastic film by integrating wireless power transmitter, polarized triangle wave generator, electrochemical cell and signage through a scalable gravure printing method. By proximity of 13.56 MHz RF reader, the printed CV tag generates 320 mHz of triangular sweep wave from +500 mV to -500 mV which enable to scan a printed electrochemical cell in the CV tag. By simply dropping any specimen solution on the electrochemical cell in the CV tag, the presence of solutes in the solution can be detected and shown on the signage of the CV tag in five sec. 10 mM of N,N,N',N'-tetramethyl-p-phenylenediamine (TMPD) was used as a standard solute to prove the working concept of fully printed disposable wireless CV tag. Within five seconds, we can wirelessly diagnose the presence of TMPD in the solution using the CV tag in the proximity of the 13.56 MHz RF reader. This fully printed and wirelessly operated flexible CV tag is the first of its kind and marks the path for the utilization of inexpensive and disposable wireless electrochemical sensor systems for initial diagnose hazardous chemicals and biological molecules to improve public hygiene and health.

  19. Abbreviations for device names: a proposed methodology with specific examples.

    PubMed

    Alam, Murad; Dover, Jeffrey S; Alam, Murad; Goldman, Mitchel P; Kaminer, Michael S; Orringer, Jeffrey; Waldorf, Heidi; Alam, Murad; Avram, Mathew; Cohen, Joel L; Draelos, Zoe Diana; Dover, Jeffrey S; Hruza, George; Kilmer, Suzanne; Lawrence, Naomi; Lupo, Mary; Metelitsa, Andrei; Nestor, Mark; Ross, E Victor

    2013-04-01

    Many devices used in dermatology lack generic names. If investigators use commercial device names, they risk the appearance of bias. Alternatively, reliance on ad-hoc names and abbreviations may confuse readers who do not recognize these. To develop a system for assigning abbreviations to denote devices commonly used in dermatology. Secondarily, to use this system to create abbreviations for FDA-approved neurotoxins and prepackaged injectable soft-tissue augmentation materials. The American Society for Dermatologic Surgery convened a Lexicon Task Force in March 2012. One charge of this Task Force was to develop criteria for assigning abbreviations to medical devices. A modified consensus process was used. Abbreviations to denote devices were to be: based on a standardized approach; transparent to the casual reader; markedly brief; and in all cases, different than the commercial names. Three-letter all caps abbreviations, some with subscripts, were assigned to denote each of the approved neurotoxins and fillers. A common system of abbreviations for medical devices in dermatology may avoid the appearance of bias while ensuring effective communication. The proposed system may be expanded to name other devices, and the ensuing abbreviations may be suitable for journal articles, continuing medical education lectures, or other academic or clinical purposes. © 2013 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  20. Optical Dating of Holocene Dune Sands in the Ferris Dune Field, Wyoming

    NASA Astrophysics Data System (ADS)

    Stokes, Stephen; Gaylord, David R.

    1993-05-01

    Optical dating of late Quaternary quartz dune sands from the Clear Creek portion of Ferris dune field, Wyoming, demonstrates the considerable potential of the technique as a chronostratigraphic tool. A sequence of radiocarbon-dated Holocene interdune strata permit optical dating of the intercalated dune sand to be tested; the concordance is good. The optical dates for the aeolian deposits not datable by radiocarbon suggest that aeolian sedimentation at Clear Creek peaked during two relatively short phases at ca. 8500 and 4000 yr B.P. The dates indicate that aeolian accumulation maxima (at least in the Clear Creek area) may not be synchronous with previously defined phases of marked aridity.

  1. An Index-Mismatch Scattering Approach to Optical Limiting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Exarhos, Gregory J.; Ferris, Kim F.; Windisch, Charles F.

    A densely packed bed of alkaline earth fluoride particles percolated by a fluid medium has been investigated as a potential index-matched optical limiter in the spirit of a Christiansen-Shelyubskii filter. Marked optical limiting was observed through this transparent medium under conditions where the focused second-harmonic output of a Q-swtiched Nd: YAG laser was on the order of about 1 J/cm2. An open-aperture Z-scan technique was used to quantify the limiting behavior. In this case, the mechanism of optical limiting is thought to be a nonlinear shift in the fluid index of refraction, resulting in an index mismatch between the disparatemore » phases at high laser fluence.« less

  2. A recent history of science cases for optical interferometry

    NASA Astrophysics Data System (ADS)

    Defrère, Denis; Aerts, Conny; Kishimoto, Makoto; Léna, Pierre

    2018-04-01

    Optical long-baseline interferometry is a unique and powerful technique for astronomical research. Since the 1980's (with I2T, GI2T, Mark I to III, SUSI, ...), optical interferometers have produced an increasing number of scientific papers covering various fields of astrophysics. As current interferometric facilities are reaching their maturity, we take the opportunity in this paper to summarize the conclusions of a few key meetings, workshops, and conferences dedicated to interferometry. We present the most persistent recommendations related to science cases and discuss some key technological developments required to address them. In the era of extremely large telescopes, optical long-baseline interferometers will remain crucial to probe the smallest spatial scales and make breakthrough discoveries.

  3. Multicolor optical polarimetry of reddened stars in the small Magellanic cloud

    NASA Technical Reports Server (NTRS)

    Magalhaes, Antonio M.; Coyne, G. V.; Piirola, Valero; Rodrigues, C. V.

    1989-01-01

    First results of an on-going program to determine the wavelength dependence of the interstellar optical polarization of reddened stars in the Small Magellanic Cloud (SMC) are presented. IUE observations of reddened stars in the SMC (Bouchet et al. 1985) generally show marked differences in the extinction law as compared to both the Galaxy and the Large Megallanic Cloud. The aim here is to determine the wavelength dependence of the optical linear polarization in the direction of several such stars in the SMC in order to further constrain the dust composition and size distribution in that galaxy.

  4. Third-order nonlinear electro-optic measurements in the smectic-? phase

    NASA Astrophysics Data System (ADS)

    Nowicka, Kamila; Bielejewska, Natalia

    2018-02-01

    The chiral smectic subphase with three-layer structure, ?, is now of great interest from the point of view of device technologies such as multistate or symmetric switching. We report that the unique nonlinear electro-optic response can serve as precise mark of the phase transition into three-layer structure. The problem is illustrated with the first and third harmonic electro-optic spectra. Furthermore, the characteristic response of the helical liquid crystal phases correlated with particular collective modes using the Debye-type relaxation method for the well-known prototype liquid crystal material (MHPOBC) are presented.

  5. Measurement of retroreflection by glass beads for road marking

    NASA Astrophysics Data System (ADS)

    Ivanov, L. A.; Kiesewetter, D. V.; Kiselev, N. N.; Malyugin, V. I.; Slugin, V. A.

    2006-04-01

    The parameters of retroreflection of the monolayer of glass beads of the different size and quality in paint for road marking are measured. The new method of simultaneous measurement of the size and coefficient of retroreflection of separate beads is offered. The system of the statistical characteristics of optical quality is introduced. The measurements for different dimensional fractions are carried out. The capability of estimation of influencing of defects of glass beads on retro reflecting properties of the materials is shown.

  6. Assessment of Performance of the Industrial Process of Bulk Vacuum Packaging of Raw Meat with Nondestructive Optical Oxygen Sensing Systems.

    PubMed

    Kelly, Caroline A; Cruz-Romero, Malco; Kerry, Joseph P; Papkovsky, Dmitri P

    2018-05-02

    The commercially-available optical oxygen-sensing system Optech-O₂ Platinum was applied to nondestructively assess the in situ performance of bulk, vacuum-packaged raw beef in three ~300 kg containers. Twenty sensors were attached to the inner surface of the standard bin-contained laminate bag (10 on the front and back sides), such that after filling with meat and sealing under vacuum, the sensors were accessible for optical interrogation with the external reader device. After filling and sealing each bag, the sensors were measured repetitively and nondestructively over a 15-day storage period at 1 °C, thus tracking residual oxygen distribution in the bag and changes during storage. The sensors revealed a number of unidentified meat quality and processing issues, and helped to improve the packaging process by pouring flakes of dry ice into the bag. Sensor utility in mapping the distribution of residual O₂ in sealed bulk containers and optimising and improving the packaging process, including handling and storage of bulk vacuum-packaged meat bins, was evident.

  7. Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in (60)Co beams.

    PubMed

    Mrčela, I; Bokulić, T; Izewska, J; Budanec, M; Fröbe, A; Kusić, Z

    2011-09-21

    A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in repeated irradiations of the same dosimeters it was found to be 3.5%. When OSL dosimeters were optically bleached between exposures, the reproducibility of repeated measurements improved to 1.0%. Dosimeters were calibrated for the entrance dose measurements and a full set of correction factors was determined. A pilot patient study that followed phantom validation testing included more than 100 measured fields with a mean relative difference of the measured entrance dose from the expected dose of 0.8% and the standard deviation of 2.5%. In conclusion, these results demonstrate that OSL dot dosimeters represent a valid alternative to already established in vivo dosimetry systems.

  8. Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in 60Co beams

    NASA Astrophysics Data System (ADS)

    Mrčela, I.; Bokulić, T.; Izewska, J.; Budanec, M.; Fröbe, A.; Kusić, Z.

    2011-09-01

    A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in 60Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in repeated irradiations of the same dosimeters it was found to be 3.5%. When OSL dosimeters were optically bleached between exposures, the reproducibility of repeated measurements improved to 1.0%. Dosimeters were calibrated for the entrance dose measurements and a full set of correction factors was determined. A pilot patient study that followed phantom validation testing included more than 100 measured fields with a mean relative difference of the measured entrance dose from the expected dose of 0.8% and the standard deviation of 2.5%. In conclusion, these results demonstrate that OSL dot dosimeters represent a valid alternative to already established in vivo dosimetry systems.

  9. Three-dimensional radiation dosimetry based on optically-stimulated luminescence

    NASA Astrophysics Data System (ADS)

    Sadel, M.; Høye, E. M.; Skyt, P. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2017-05-01

    A new approach to three-dimensional (3D) dosimetry based on optically-stimulated luminescence (OSL) is presented. By embedding OSL-active particles into a transparent silicone matrix (PDMS), the well-established dosimetric properties of an OSL material are exploited in a 3D-OSL dosimeter. By investigating prototype dosimeters in standard cuvettes in combination with small test samples for OSL readers, it is shown that a sufficient transparency of the 3D-OSL material can be combined with an OSL response giving an estimated >10.000 detected photons in 1 second per 1mm3 voxel of the dosimeter at a dose of 1 Gy. The dose distribution in the 3D-OSL dosimeters can be directly read out optically without the need for subsequent reconstruction by computational inversion algorithms. The dosimeters carry the advantages known from personal-dosimetry use of OSL: the dose distribution following irradiation can be stored with minimal fading for extended periods of time, and dosimeters are reusable as they can be reset, e.g. by an intense (bleaching) light field.

  10. Optical study on the dependence of breast tissue composition and structure on subject anamnesis

    NASA Astrophysics Data System (ADS)

    Taroni, Paola; Quarto, Giovanna; Pifferi, Antonio; Abbate, Francesca; Balestreri, Nicola; Menna, Simona; Cassano, Enrico; Cubeddu, Rinaldo

    2015-07-01

    Time domain multi-wavelength (635 to 1060 nm) optical mammography was performed on 200 subjects to estimate their average breast tissue composition in terms of oxy- and deoxy-hemoglobin, water, lipid and collagen, and structural information, as provided by scattering parameters (amplitude and power). Significant (and often marked) dependence of tissue composition and structure on age, menopausal status, body mass index, and use of oral contraceptives was demonstrated.

  11. Optical Limiting in Photonic Crystal Fibers

    DTIC Science & Technology

    2004-12-01

    Optical Limiting in Photonic Crystal Fibers Mark Bloemer, Michael Scalora , Wayne Davenport, and Evgeni Poliakov(NRC Postdoc) RDECOM, Aviation...Shcherbakov, E. Wintner, M. Scalora , and A. M. Zheltikov, Appl. Opt., in press. 7 21. C. M. de Sterke and J. E. Sipe, Prog. Opt. 33, 203 (1994... Scalora , J..P. Dowling, C.M. Bowden, and M.J. Bloemer, Phys. Rev. Lett. 73, 1368 (1994). 26. M.D. Tocci, M.J. Bloemer, M. Scalora , J.P. Dowling

  12. Optical Docking Aid Containing Fresnel Lenses

    NASA Technical Reports Server (NTRS)

    Pierce, Cole J.

    1995-01-01

    Proposed device provides self-contained visual cues to aid in docking. Similar to devices used to guide pilots in landing on aircraft carriers. Positions and directions of beams of light give observer visual cues of position relative to docking target point. Optical assemblies generate directed, diverging beams of light that, together, mark approach path to docking point. Conceived for use in docking spacecraft at Space Station Freedom, device adapted to numerous industrial docking and alignment applications.

  13. Disc resonator gyroscope fabrication process requiring no bonding alignment

    NASA Technical Reports Server (NTRS)

    Shcheglov, Kirill V. (Inventor)

    2010-01-01

    A method of fabricating a resonant vibratory sensor, such as a disc resonator gyro. A silicon baseplate wafer for a disc resonator gyro is provided with one or more locating marks. The disc resonator gyro is fabricated by bonding a blank resonator wafer, such as an SOI wafer, to the fabricated baseplate, and fabricating the resonator structure according to a pattern based at least in part upon the location of the at least one locating mark of the fabricated baseplate. MEMS-based processing is used for the fabrication processing. In some embodiments, the locating mark is visualized using optical and/or infrared viewing methods. A disc resonator gyroscope manufactured according to these methods is described.

  14. Alternate reading strategies and variable asymmetry of the planum temporale in adult resilient readers.

    PubMed

    Welcome, Suzanne E; Leonard, Christiana M; Chiarello, Christine

    2010-05-01

    Resilient readers are characterized by impaired phonological processing despite skilled text comprehension. We investigated orthographic and semantic processing in resilient readers to examine mechanisms of compensation for poor phonological decoding. Performance on phonological (phoneme deletion, pseudoword reading), orthographic (orthographic choice, orthographic analogy), and semantic (semantic priming, homograph resolution) tasks was compared between resilient, poor and proficient readers. Asymmetry of the planum temporale was investigated in order to determine whether atypical readers showed unusual morphology in this language-relevant region. Resilient readers showed deficits on phonological tasks similar to those shown by poor readers. We obtained no evidence that resilient readers compensate via superior orthographic processing, as they showed neither exceptional orthographic skill nor increased reliance on orthography to guide pronunciation. Resilient readers benefited more than poor or proficient readers from semantic relationships between words and experienced greater difficulty when such relationships were not present. We suggest, therefore, that resilient readers compensate for poor phonological decoding via greater reliance on word meaning relationships. The reading groups did not differ in mean asymmetry of the planum temporale. However, resilient readers showed greater variability in planar asymmetry than proficient readers. Poor readers also showed a trend towards greater variability in planar asymmetry, with more poor readers than proficient readers showing extreme asymmetry. Such increased variability suggests that university students with less reading skill display less well regulated brain anatomy than proficient readers. Copyright 2010 Elsevier Inc. All rights reserved.

  15. Instructional Review: An Introduction to Optical Methods for Characterizing Liquid Crystals at Interfaces

    PubMed Central

    Miller, Daniel S.; Carlton, Rebecca J.; Mushenheim, Peter C.; Abbott, Nicholas L.

    2013-01-01

    This Instructional Review describes methods and underlying principles that can be used to characterize both the orientations assumed spontaneously by liquid crystals (LCs) at interfaces and the strength with which the LCs are held in those orientations (so-called anchoring energies). The application of these methods to several different classes of LC interfaces is described, including solid and aqueous interfaces as well as planar and non-planar interfaces (such as those that define a LC-in-water emulsion droplet). These methods, which enable fundamental studies of the ordering of LCs at polymeric, chemically-functionalized and biomolecular interfaces, are described in this article at a level that can be easily understood by a non-expert reader such as an undergraduate or graduate student. We focus on optical methods because they are based on instrumentation that is found widely in research and teaching laboratories. PMID:23347378

  16. Noncontacting-optical-strain device

    NASA Technical Reports Server (NTRS)

    Silver, R. H.

    1970-01-01

    Noncontacting-strain-measuring gauge and extensometer remotely measures the mechanical displacement along the entire length of a test specimen. Measurement is accomplished by continuous scanning of a reflected light from reflective bench markings or stripes previously affixed to the specimen.

  17. Nationwide Databases in Orthopaedic Surgery Research.

    PubMed

    Bohl, Daniel D; Singh, Kern; Grauer, Jonathan N

    2016-10-01

    The use of nationwide databases to conduct orthopaedic research has expanded markedly in recent years. Nationwide databases offer large sample sizes, sampling of patients who are representative of the country as a whole, and data that enable investigation of trends over time. The most common use of nationwide databases is to study the occurrence of postoperative adverse events. Other uses include the analysis of costs and the investigation of critical hospital metrics, such as length of stay and readmission rates. Although nationwide databases are powerful research tools, readers should be aware of the differences between them and their limitations. These include variations and potential inaccuracies in data collection, imperfections in patient sampling, insufficient postoperative follow-up, and lack of orthopaedic-specific outcomes.

  18. Embedded processor extensions for image processing

    NASA Astrophysics Data System (ADS)

    Thevenin, Mathieu; Paindavoine, Michel; Letellier, Laurent; Heyrman, Barthélémy

    2008-04-01

    The advent of camera phones marks a new phase in embedded camera sales. By late 2009, the total number of camera phones will exceed that of both conventional and digital cameras shipped since the invention of photography. Use in mobile phones of applications like visiophony, matrix code readers and biometrics requires a high degree of component flexibility that image processors (IPs) have not, to date, been able to provide. For all these reasons, programmable processor solutions have become essential. This paper presents several techniques geared to speeding up image processors. It demonstrates that a gain of twice is possible for the complete image acquisition chain and the enhancement pipeline downstream of the video sensor. Such results confirm the potential of these computing systems for supporting future applications.

  19. Reply to Discussion by Zekai Șen on "Modeling karst spring hydrograph recession based on head drop at sinkholes"

    NASA Astrophysics Data System (ADS)

    Field, Malcolm S.; Goldscheider, Nico; Li, Guangquan

    2018-02-01

    We are pleased to learn that the model presented in our paper dealing with the "modeling karst spring hydrograph recession based on head drop at sinkholes," published in the Journal of Hydrology in 2016 (Li et al., 2016), is of interest to readers of this journal. Our study presented a new non-exponential model for assessing spring hydrographs in terms of head drop at flooded sinkholes, as an extension of an earlier model proposed by Li and Field (2014). In both papers, we used two spring hydrographs measured in the St. Marks Karst Watershed in northwest Florida to test the applicability and to verify the validity of our models.

  20. Opening editorial 2016: Changes in scope and structure.

    PubMed

    Kazak, Anne E

    2016-01-01

    This issue of American Psychologist (AP) marks historic changes in the editorial structure and leadership of AP and related shifts in the refinement of the mission of AP and the types of papers AP will publish. As the new editor-in-chief (EIC) of AP, I am enthusiastic about psychology and the many ways that psychological knowledge can improve our lives and the societies in which we live. AP will continue to reflect the whole of psychology and welcomes the input and involvement of individuals from all areas of the field. In this editorial, I offer readers a brief overview of current journal activities and procedures for the flagship journal of the American Psychological Association (APA). (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  1. Mechanism of demyelination after HSV type I intraocular injection in rabbits.

    PubMed

    Narang, H K

    1980-02-01

    Intraocular injection of herpes simplex virus (HSV) type I into the vitreous body of 18-day-old rabbits induced, on the 7th day post-inoculation, neurological signs with marked head jerking and atazia. Examination of semi-serial 1-micrometers thick sections of the whole lengths of right and left optic nerves and chiasma of 4--64 days post-inoculated rabbits revealed a small lesion, restricted to the medial side, which had extended 2--3 mm, during the first 4 days, along the optic nerve. Ahead of the developing lesion marked chromatin changes of neuroglial cells were noticed followed by cuffing of blood vessels, infiltration by macrophages, demyelination and remyelination. The present study indicated that demyelination occurred following the infection of the myelinating cells. It appeared that virus did not become latent and many cells survived the viral attack. Repeated episodies of viral activity caused further damage while repair did not keep pace.

  2. The effect of different bleaching wavelengths on the sensitivity of Al{sub 2}O{sub 3}:C optically stimulated luminescence detectors (OSLDs) exposed to 6 MV photon beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omotayo, Azeez A.; Cygler, Joanna E.; Sawakuchi, Gabriel O.

    2012-09-15

    Purpose: To determine the effect of different bleaching wavelengths on the response of Al{sub 2}O{sub 3}:C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. Methods: In this study the authors used nanoDot OSLDs readout with a MicroStar reader. The authors first characterized the dose-response, fading, and OSL signal loss of OSLDs exposed to doses from 0.5 to 10 Gy. To determine the effect of different bleaching wavelengths on the OSLDs' response, the authors optically treated the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120, andmore » 600 min and (ii) with a long-pass filter for 55, 600, and 2000 min. Changes in the OSLDs' sensitivity were determined for an irradiation-readout-bleaching-readout cycle after irradiations with 1 and 10 Gy dose fractions. Results: The OSLDs presented supralinearity for doses of 2 Gy and above. The signal loss rates for sequential readouts were (0.287 {+-} 0.007)% per readout in the reader's strong-stimulation mode, and (0.019 {+-} 0.002)% and (0.035 {+-} 0.007)% per readout for doses of 0.2 and 10 Gy, respectively, in the reader's weak-stimulation mode. Fading half-life values ranged from (0.98 {+-} 0.14) min to (1.77 {+-} 0.24) min and fading showed dose dependence for the first 10-min interval. For 10 and 55 min bleaching using modes (i) and (ii), the OSL signal increased 14% for an accumulated dose of 7 Gy (1 Gy fractions). For OSLDs exposed to 10 Gy fractions, the OSL signal increased 30% and 25% for bleaching modes (i) and (ii) and accumulated dose of 70 Gy, respectively. For 120 and 600 min bleaching using modes (i) and (ii), the OSL signal increased 2.7% and 1.5% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 14% for bleaching mode (i) (120 min bleaching) and decreased 1.3% for bleaching mode (ii) (600 min bleaching) for an accumulated dose of 70 Gy. For 600 and 2000 min bleaching using modes (i) and (ii), the signal increased 2.3% and 1.8% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 10% for mode (i) (600 min bleaching) and decreased 2.5% for mode (ii) (2000 min bleaching) for an accumulated dose of 70 Gy. Conclusions: The dose-response of nanoDot OSLDs read using the MicroStar reader presented supralinearity for doses of 2 Gy and above. The signal loss as a function of sequential readouts depended on dose. Fading also depended on dose for the first 10-min interval. For dose fractions of 1 and 10 Gy, OSLDs may be reused within 3% and 5% accuracies up to the maximum accumulated dose of 7 and 70 Gy investigated in this study, respectively. These accuracies were obtained after the OSLDs were bleached with a light source with wavelengths above about 495 nm. The authors also concluded that changes in sensitivity of OSLDs depended on bleaching time, accumulated dose, and wavelength spectrum of the bleaching source.« less

  3. Enhancement of image contrast by fluorescence in microtechnology

    NASA Astrophysics Data System (ADS)

    Berndt, Michael; Tutsch, Rainer

    2005-06-01

    New developments in production technology increasingly focus on hybrid microsystems. Especially for systems with movable components, the process step of assembly is mandatory. In general, the accuracy of positioning of the parts has to be better than 1 μm. This makes specialized and automated production equipment necessary, which can lead to a conflict with the aim of flexibility of the range of products. Design for manufacturing is a well known remedy. Assembly aids are common practice today. These features of the workpieces bear no functionality for the end product but considerably ease certain process steps. By standardization of assembly aids generalized production equipment free from product-specific features could be developed. In our contribution, we demonstrate the photogrammetric determination of the positions of workpieces without reference to their exterior shape, using circular fiducial marks of 150 μm in diameter. The surface properties of the workpieces, however, still have an influence on image formation. As an example, the marks may be hidden by local specular reflections. A solution to this problem is to add an exclusive optical property to the fiducial marks to get an image with high contrast against the surface of the workpiece. In biology and medicine samples are stained with fluorescing dyes to enhance the contrast in optical microscopy. In fluorochromes, light of a characteristic wavelength is emitted after the absorption of light with a shorter wavelength. In our experiments we added a fluorochrome to a common photoresist and coated the surface of the workpiece with a thin layer thereof. Using photolithography as a patterning technique we generated fiducial marks with structures down to 25 μm. These marks can be identified by their characteristic emission wavelength under short-wavelength illumination. Only the fiducial marks remain visible in the images and processing these images is straightforward. The generation of fluorescing patterns by photolithography opens new possibilities for testing and process control in many fields of microtechnology.

  4. Clinicopathologic correlation of chorioretinitis sclopetaria.

    PubMed

    Dubovy, S R; Guyton, D L; Green, W R

    1997-01-01

    To report the clinicopathologic features in the eye of a patient who sustained a traumatic chorioretinal rupture from a gunshot wound to the orbit, chorioretinitis sclopetaria, with clinical follow up of more than 20 years. The patient was studied ophthalmoscopically and by fluorescein angiography after the trauma and was seen intermittently thereafter. The eyes were obtained postmortem; sections of the central portion of the right eye, including the macula and optic nerve head, and the inferior cap were examined by light microscopy. Histopathologic study of the right eye showed partial loss of the nerve fiber and ganglion cell layers in the macular area, temporal peripapillary and macular loss of the photoreceptors with hypertrophy and hyperplasia of the retinal pigment epithelium, an epiretinal membrane, and three defects in Bruch's membrane. Inferiorly, there was a 5-mm defect in choroid, Bruch's membrane, and retina. These structures were replaced by a loose and dense fibrous connective tissue. The sclera and a long posterior ciliary nerve remained intact. A thin fibrovascular tissue from the choroid extended into the subretinal space where it was covered by retinal pigment epithelium and thickened basement membrane in the posterior aspect of the inferior lesion. Marked hemiatrophy of the optic nerve was present. The clinicopathologic features of chorioretinitis sclopetaria include direct traumatic chorioretinal rupture followed by marked fibrovascular proliferation with variable replacement of choroid and retina with no retinal detachment. Posteriorly, indirect macular choroidal ruptures with hyperplasia and migration of the retinal pigment epithelium into the retina and choroid, epiretinal membrane formation, loss of photoreceptors, and marked hemiatrophy of the optic nerve were present.

  5. Effect Of Laser CO{sub 2} Parameters In Marking Of Glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khanafi-Benghalem, Nafissa; Boudoukha, Hassina; Benghalem, Kamel

    Currently many techniques of marking are exploited in a great number of sectors, on various materials (cardboard, textile, wood, leather, plastic, metal, ceramics and glass). The printing is done on supports of great or small dimension for all geometrical forms (plane, round, conical and ovalised). We can print colour as much than we wish. The marking technology for the identification of the glass parts knows a remarkable development carried by the new needs for the industrialists using transparent materials such as the optical, chemical, pharmaceutical sectors, the luxury and drink industries or publicity and decoration (neon signs, advertising mirrors). Themore » objective of our work consists particularly in engraving on glass the measurement scales forming a whole of ordered graduation which the goal is to carry out reading systems of measuring apparatus about 1/10 {mu}m of precision. We used as tool for marking the laser CO{sub 2}. Our choice is justified by the flexibility of the laser, the permanent lifespan of the graduations carried out and the guarantee of the facility of reading incidentally the precision and the accuracy of the measuring apparatus. The study parameters of the laser beam are the velocity (400, 600, 800, 1000 m/s.), the power (25, 75 and 80% of 25W) and the numbers pass (one, two and three pass). The optical observations results obtained suggest that the highest and the average power used remain the favourable parameters for the quality of the graduations carried out.« less

  6. Effect Of Laser CO2 Parameters In Marking Of Glass

    NASA Astrophysics Data System (ADS)

    Khanafi-Benghalem, Nafissa; Benghalem, Kamel; Boudoukha, Hassina

    2008-09-01

    Currently many techniques of marking are exploited in a great number of sectors, on various materials (cardboard, textile, wood, leather, plastic, metal, ceramics and glass). The printing is done on supports of great or small dimension for all geometrical forms (plane, round, conical and ovalised). We can print colour as much than we wish. The marking technology for the identification of the glass parts knows a remarkable development carried by the new needs for the industrialists using transparent materials such as the optical, chemical, pharmaceutical sectors, the luxury and drink industries or publicity and decoration (neon signs, advertising mirrors). The objective of our work consists particularly in engraving on glass the measurement scales forming a whole of ordered graduation which the goal is to carry out reading systems of measuring apparatus about 1/10 μm of precision. We used as tool for marking the laser CO2. Our choice is justified by the flexibility of the laser, the permanent lifespan of the graduations carried out and the guarantee of the facility of reading incidentally the precision and the accuracy of the measuring apparatus. The study parameters of the laser beam are the velocity (400, 600, 800, 1000 m/s.), the power (25, 75 and 80% of 25W) and the numbers pass (one, two and three pass). The optical observations results obtained suggest that the highest and the average power used remain the favourable parameters for the quality of the graduations carried out.

  7. Advanced Spatial-Division Multiplexed Measurement Systems Propositions—From Telecommunication to Sensing Applications: A Review

    PubMed Central

    Weng, Yi; Ip, Ezra; Pan, Zhongqi; Wang, Ting

    2016-01-01

    The concepts of spatial-division multiplexing (SDM) technology were first proposed in the telecommunications industry as an indispensable solution to reduce the cost-per-bit of optical fiber transmission. Recently, such spatial channels and modes have been applied in optical sensing applications where the returned echo is analyzed for the collection of essential environmental information. The key advantages of implementing SDM techniques in optical measurement systems include the multi-parameter discriminative capability and accuracy improvement. In this paper, to help readers without a telecommunication background better understand how the SDM-based sensing systems can be incorporated, the crucial components of SDM techniques, such as laser beam shaping, mode generation and conversion, multimode or multicore elements using special fibers and multiplexers are introduced, along with the recent developments in SDM amplifiers, opto-electronic sources and detection units of sensing systems. The examples of SDM-based sensing systems not only include Brillouin optical time-domain reflectometry or Brillouin optical time-domain analysis (BOTDR/BOTDA) using few-mode fibers (FMF) and the multicore fiber (MCF) based integrated fiber Bragg grating (FBG) sensors, but also involve the widely used components with their whole information used in the full multimode constructions, such as the whispering gallery modes for fiber profiling and chemical species measurements, the screw/twisted modes for examining water quality, as well as the optical beam shaping to improve cantilever deflection measurements. Besides, the various applications of SDM sensors, the cost efficiency issue, as well as how these complex mode multiplexing techniques might improve the standard fiber-optic sensor approaches using single-mode fibers (SMF) and photonic crystal fibers (PCF) have also been summarized. Finally, we conclude with a prospective outlook for the opportunities and challenges of SDM technologies in optical sensing industry. PMID:27589754

  8. Advanced Spatial-Division Multiplexed Measurement Systems Propositions-From Telecommunication to Sensing Applications: A Review.

    PubMed

    Weng, Yi; Ip, Ezra; Pan, Zhongqi; Wang, Ting

    2016-08-30

    The concepts of spatial-division multiplexing (SDM) technology were first proposed in the telecommunications industry as an indispensable solution to reduce the cost-per-bit of optical fiber transmission. Recently, such spatial channels and modes have been applied in optical sensing applications where the returned echo is analyzed for the collection of essential environmental information. The key advantages of implementing SDM techniques in optical measurement systems include the multi-parameter discriminative capability and accuracy improvement. In this paper, to help readers without a telecommunication background better understand how the SDM-based sensing systems can be incorporated, the crucial components of SDM techniques, such as laser beam shaping, mode generation and conversion, multimode or multicore elements using special fibers and multiplexers are introduced, along with the recent developments in SDM amplifiers, opto-electronic sources and detection units of sensing systems. The examples of SDM-based sensing systems not only include Brillouin optical time-domain reflectometry or Brillouin optical time-domain analysis (BOTDR/BOTDA) using few-mode fibers (FMF) and the multicore fiber (MCF) based integrated fiber Bragg grating (FBG) sensors, but also involve the widely used components with their whole information used in the full multimode constructions, such as the whispering gallery modes for fiber profiling and chemical species measurements, the screw/twisted modes for examining water quality, as well as the optical beam shaping to improve cantilever deflection measurements. Besides, the various applications of SDM sensors, the cost efficiency issue, as well as how these complex mode multiplexing techniques might improve the standard fiber-optic sensor approaches using single-mode fibers (SMF) and photonic crystal fibers (PCF) have also been summarized. Finally, we conclude with a prospective outlook for the opportunities and challenges of SDM technologies in optical sensing industry.

  9. Reading strategies of fast and slow readers.

    PubMed

    Haberlandt, K F; Graesser, A C; Schneider, N J

    1989-09-01

    In three subject-paced experiments we evaluated reading patterns at the word, line, and sentence level for fast and slow readers. A moving-window method was used to collect word reading times for natural texts. At the word level, reading times of word N were influenced by features of word N-1 for fast readers but not for slow readers. The lag effect exhibited by fast readers indicates that they continue to process a word when it is no longer in view, thus limiting the notion of immediate processing. Contrary to our initial expectation that fast readers would process only a single new argument from a sentence, whereas slow readers would process several new arguments, we found that both reader groups adopted a many-argument strategy. However, fast and slow readers differed in terms of the text units (lines vs. sentences) defining the new-argument effects: Fast readers exhibited greater new-argument effects relative to lines, whereas slow readers exhibited greater new-argument effects relative to sentences. Specifically, slow readers integrated the new arguments primarily at the end of the sentence, whereas fast readers did so at line boundaries. These results are discussed in terms of a buffer-and-integrate model of reading comprehension.

  10. Book Review:

    NASA Astrophysics Data System (ADS)

    Arimondo, Ennio

    2004-07-01

    For many years the Institute of Physics has published books on hot topics based on a collection of reprints from different journals, including some remarks by the editors of each volume. The book on Optical Angular Momentum, edited by L Allen, S M Barnett and M J Padgett, is a recent addition to the series. It reproduces forty four papers originally published in different journals and in a few cases it provides direct access to works not easily accessible to a web navigator. The collection covers nearly a hundred years of progress in physics, starting from an historic 1909 paper by Poynting, and ending with a 2002 paper by Padgett, Barnett and coworkers on the measurement of the orbital angular momentum of a single photon. The field of optical angular momentum has expanded greatly, creating an interdisciplinary attraction for researchers operating in quantum optics, atomic physics, solid state physics, biophysics and quantum information theory. The development of laser optics, especially the control of single mode sources, has made possible the specific design of optical radiation modes with a high degree of control on the light angular momentum. The editors of this book are important figures in the field of angular momentum, having contributed to key progress in the area. L Allen published an historical paper in 1999, he and M J Padgett (together with M Babiker) produced few years ago a long review article which is today still the most complete basic introduction to the angular momentum of light, while S M Barnett has contributed several high quality papers to the progress of this area of physics. The editors' choice provides an excellent overview to all readers, with papers classified into eight different topics, covering the basic principles of the light and spin and orbital angular momentum, the laboratory tools for creating laser beams carrying orbital angular momentum, the optical forces and torques created by laser beams carrying angular momentum on particles and atoms, the rotational frequency shift, the angular momentum in nonlinear optics, and the entanglement of angular momentum. An introductory part contains the historic paper by Poynting mentioned above, and another one by Beth in 1936 where the angular momentum of light was measured through a mechanical detection. It also includes a paper by Allen written in 2002 as a long foreword to a Special Issue of Journal of Optics B: Quantum and Semiclassical Optics where more recent major developments within this field were illustrated. Both experimental and theoretical aspects of orbital angular momentum are covered, the editors themselves having, in fact, contributed to developments in both aspects. A newcomer to the field will immediately realize the most important issues connected to the generation, propagation and application of laser beams with orbital angular momentum. A reader already acquainted with the main features of the topic may skip the first papers of all the sections listed above, and focus his or her attention to those papers devoted to the more recent developments. This is therefore a book to be considered with great attention by a large community. My only, minor, remark on the choice of the papers reproduced within this book is that applications to solid state physics, such as liquid crystals, are not mentioned. The field keeps expanding. For instance, very recently optical beams bearing optical angular momentum have been recognized as potential systems for doing quantum computation. Optical tweezers have defined a revolution in optical manipulation for research in the fields of biology, physical chemistry and soft condensed matter physics. The angular momentum of light also has applications in atom optics. Good textbooks are essential in establishing and expanding any field; they help broaden the interest in the field and ensure that the next generation of physicists can learn it. The present book satisfies those requirements because it provides to graduate students, to newcomers to the field, and also to experienced researchers an easy access to the basic contributions.

  11. 49 CFR Appendix A to Part 221 - Procedures for Approval of Rear End Marking Devices

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... description of the device including the type, luminance description, size of lens, manufacturer and catalog number, lamp manufacturer, lamp type and model number, and any auxiliary optics used. (2) A certification...

  12. 49 CFR Appendix A to Part 221 - Procedures for Approval of Rear End Marking Devices

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... description of the device including the type, luminance description, size of lens, manufacturer and catalog number, lamp manufacturer, lamp type and model number, and any auxiliary optics used. (2) A certification...

  13. Optical legacy of Imperial College London

    NASA Astrophysics Data System (ADS)

    Kidger Webb-Moore, Tina E.

    2016-10-01

    The Industrial Revolution, beginning primarily in the UK, generated an increasing need for highly skilled technical people. Throughout the 19th century, technical instruction increased dramatically and the formation of schools specializing in science and technology grew quickly. In England, there was much motivation in favour of a national prestige center for science and technology centered in London. Central among the motivating forces was Queen Victoria's husband, Prince Albert. Although there were already existing specialist science and technology institutions in major English cities, the growth of superior institutions in other countries within Europe, especially Germany and the Charlottenburg area of Berlin (e.g., the Berlin Technical High School), encouraged important English dignitaries to become more competitive with continental Europe. As a result of this strong continental motivation, several science and technology institutions were built in the south Kensington part of London during the latter half of the 19th century. Imperial College, founded at the start of the 20th century, was a culmination and consolidation of several of these 19th century English institutions. Optical science and technology was an early beneficiary of the founding of Imperial College. This paper will attempt to provide the reader with an understanding of how great was the influence of the optical section of Imperial College in the further development of the world's optical science and technology.

  14. Germanium-doped optical fiber for real-time radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Mizanur Rahman, A. K. M.; Zubair, H. T.; Begum, Mahfuza; Abdul-Rashid, H. A.; Yusoff, Z.; Ung, N. M.; Mat-Sharif, K. A.; Wan Abdullah, W. S.; Amouzad Mahdiraji, Ghafour; Amin, Y. M.; Maah, M. J.; Bradley, D. A.

    2015-11-01

    Over the past three decades growing demand for individualized in vivo dosimetry and subsequent dose verification has led to the pursuit of newer, novel and economically feasible materials for dosimeters. These materials are to facilitate features such as real-time sensing and fast readouts. In this paper, purposely composed SiO2:Ge optical fiber is presented as a suitable candidate for dosimetry. The optical fiber is meant to take advantage of the RL/OSL technique, providing both online remote monitoring of dose rate, and fast readouts for absorbed dose. A laboratory-assembled OSL reader has been used to acquire the RL/OSL response to LINAC irradiations (6 MV photons). The notable RL characteristics observed include constant level of luminescence for the same dose rate (providing better consistency compared to TLD-500), and linearity of response in the radiotherapy range (1 Gy/min to 6 Gy/min). The OSL curve was found to conform to an exponential decay characteristic (illumination with low LED source). The Ge doping resulted in an effective atomic number, Zeff, of 13.5 (within the bone equivalent range). The SiO2:Ge optical fiber sensor, with efficient coupling, can be a viable solution for in vivo dosimetry, besides a broad range of applications.

  15. Laser speckle based digital optical methods in structural mechanics: A review

    NASA Astrophysics Data System (ADS)

    De la Torre, I. Manuel; Hernández Montes, María del Socorro; Flores-Moreno, J. Mauricio; Santoyo, Fernando Mendoza

    2016-12-01

    Laser Speckle Correlation, Electronic Speckle Pattern Interferometry and Digital Holographic interferometry have evolved for decades to become relevant techniques in many fields of today's wide spectrum of knowledge and disciplines. Indeed, with today's advances in optics, photonics, electronics and computing there are many important applications for them and strictly speaking there are an almost infinite number of applications that one can think of, as they are non-contact optical techniques that can be used to measure mechanical parameters ranging from a few microns to hundreds of nanometers. In this review we will explore and discuss some relevant applications in structural mechanics in the fields of materials in engineering, biomedical and art preservation and restoration. This work will take the reader from a succinct historical account on the development of these techniques, followed by a brief theoretical description for each one that will then facilitate the introduction of the results chosen as the key applications, ending the review with the conclusions. From the myriad of papers now available in the web, we will only present those that we believe are the most illustrative applications within three lustrum, 2000 to 2015, all set to give a frame that place these optical techniques as mature technologies with an absolute relevance to conduct metrology in many fields.

  16. Assessment of GeB doped SiO2 optical fiber for the application of remote radiation sensing system

    NASA Astrophysics Data System (ADS)

    Alawiah, A.; Fadhli, M. M.; Bauk, S.; Abdul-Rashid, H. A.; Maah, M. J.

    2013-12-01

    The research and development efforts on the silica (SiO2) optical fiber for application in radiation sensing and other dosimetry field have become quite active. The widely used LiF based dosimeter (TLD) has shown a relatively low reproducibility and there is a time delay in dose assessment which loses its capability as direct real-time dose assessment dosimeters unlike diodes. The macroscopic size of the optical fiber generally does not allow direct in vivo dose sensing in the inner organ for radiotherapy and medical imaging. A flat optical fiber (FF) with nominal dimensions of (0.08 x10 x 10) mm3 of pure silica SiO2 and GeO2 with Boron doped silica fiber SiO2 was selected for this research. The Germanium was used a dopant to enhance the flat optical fiber to reach much higher responsiveness and dose sensitivity in high energy and high dose irradiation. Together with this combination, both TLD dimension and dose assessment issues was hoped to be overcome. The research conducted by comparing the response of pure silica SiO2 flat optical fiber with a GeO2 with Boron doped silica SiO2 flat optical fiber. The FF sample was annealed at 400°C for one hour before irradiated. Kinetic parameters and dosimetric glow curve of TL response and sensitivity were studied with respect to the electron beam of high dose of micro beam irradiation of 1.0 kGy, 5.0 kGy, 10.0 kGy, 50.0 kGy, 100.0 kGy, 500.0 kGy, and 1.0 MGy using Singapore Synchrotron Light Source's (PCIT) beamline. The PCIT operates at 500mA current with real time current range from 90-100mA, dose rate of 3.03 MGy/hour and energy at 8.9KeV. The source to Source Surface Distance (SSD) was at 6.0 cm, with a field size of 20mm × 8mm diameter of a half circle. The TL response was measured using a TLD reader Harshaw Model 3500. The Time-Temperature-Profile (TTP) of the reader was obtained to a preheat temperature of 150 °C for 5 s, the output signal being acquired at a temperature ramprate of 35 °Cs-1, acquisition time of 10 s and a maximum temperature of 400 °C each of the FF samples. All reading was taken under N2 gas flow, suppressing oxidation and potential triboluminescence. The proposed FF shows the excellent TL response for high energy irradiation and good reproducibility and exhibits a very low rate of fading and low variation background signal. From these results, the proposed FF can be used as a radiation dosimeter in remote radiation sensing and favorably compares with the widely used of LiF based dosimeter on common medical radiotherapy application.

  17. Novel label-free biosensing technology for monitoring of aqueous solutions (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kehl, Florian; Bielecki, Robert; Follonier, Stephane; Dorokhin, Denis

    2016-03-01

    Waste water, drinking water and other industrial water sources are more and more/increasingly polluted with a large variety of contaminants, such as pesticides or residuals of pharmaceuticals. These compounds can impact human and animal organisms and lead to serious health issues. Today, in order to analyze the presence and quantity of the abovementioned micropollutants, samples are typically sent to specialized centralized laboratories and their processing may take up to several days. In order to meet the demand for continuous and consistent monitoring of aqueous solutions we propose a novel label-free technology system comprising proprietary chip and reader device designs. The core of the system is constituted by a planar-grated-waveguide (PGW) chip. Label-free biosensors, based on PGWs are sensitive to effective refractive index changes caused by the adsorption of biomolecules (micropollutants) onto the sensor surface or due to refractive index changes of the bulk solution. The presented reader device operates with a novel readout concept based on a scanning MEMS mirror for the angular interrogation of input grating couplers at a high repetition rate. The reader has fully integrated optics, electronics and fluidics and at the same time consumes limited energy (portable, field use ready). In the recent experiments, the effectiveness of the technology has been demonstrated with various liquids and bioassays showing (i) an excellent refractometric sensitivity with a limit of detection towards effective refractive index changes of ▵neff < 2 x 10-7, and (ii) the capability to perform affinity measurements for large (<150 kDa) and small (<250 Da) molecules.

  18. Cellphone-based hand-held microplate reader for point-of-care ELISA testing (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Berg, Brandon; Cortazar, Bingen; Tseng, Derek; Ozkan, Haydar; Feng, Steve; Wei, Qingshan; Chan, Raymond Y.; Burbano, Jordi; Farooqui, Qamar; Lewinski, Michael; Di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-03-01

    Enzyme-linked immunosorbent assay (ELISA) in a microplate format has been a gold standard first-line clinical test for diagnosis of various diseases including infectious diseases. However, this technology requires a relatively large and expensive multi-well scanning spectrophotometer to read and quantify the signal from each well, hindering its implementation in resource-limited-settings. Here, we demonstrate a cost-effective and handheld smartphone-based colorimetric microplate reader for rapid digitization and quantification of immunoserology-related ELISA tests in a conventional 96-well plate format at the point of care (POC). This device consists of a bundle of 96 optical fibers to collect the transmitted light from each well of the microplate and direct all the transmission signals from the wells onto the camera of the mobile-phone. Captured images are then transmitted to a remote server through a custom-designed app, and both quantitative and qualitative diagnostic results are returned back to the user within ~1 minute per 96-well plate by using a machine learning algorithm. We tested this mobile-phone based micro-plate reader in a clinical microbiology lab using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests on 1138 remnant patient samples (roughly 50% training and 50% testing), and achieved an overall accuracy of ~99% or higher for each ELISA test. This handheld and cost-effective platform could be immediately useful for large-scale vaccination monitoring in low-infrastructure settings, and also for other high-throughput disease screening applications at POC.

  19. Thermal effects of laser marking on microstructure and corrosion properties of stainless steel.

    PubMed

    Švantner, M; Kučera, M; Smazalová, E; Houdková, Š; Čerstvý, R

    2016-12-01

    Laser marking is an advanced technique used for modification of surface optical properties. This paper presents research on the influence of laser marking on the corrosion properties of stainless steel. Processes during the laser beam-surface interaction cause structure and color changes and can also be responsible for reduction of corrosion resistance of the surface. Corrosion tests, roughness, microscopic, energy dispersive x-ray, grazing incidence x-ray diffraction, and ferrite content analyses were carried out. It was found that increasing heat input is the most crucial parameter regarding the degradation of corrosion resistance of stainless steel. Other relevant parameters include the pulse length and pulse frequency. The authors found a correlation between laser processing parameters, grazing incidence x-ray measurement, ferrite content, and corrosion resistance of the affected surface. Possibilities and limitations of laser marking of stainless steel in the context of the reduction of its corrosion resistance are discussed.

  20. Aircraft vortex marking program

    NASA Technical Reports Server (NTRS)

    Pompa, M. F.

    1979-01-01

    A simple, reliable device for identifying atmospheric vortices, principally as generated by in-flight aircraft and with emphasis on the use of nonpolluting aerosols for marking by injection into such vortex (-ices) is presented. The refractive index and droplet size were determined from an analysis of aerosol optical and transport properties as the most significant parameters in effecting vortex optimum light scattering (for visual sighting) and visual persistency of at least 300 sec. The analysis also showed that a steam-ejected tetraethylene glycol aerosol with droplet size near 1 micron and refractive index of approximately 1.45 could be a promising candidate for vortex marking. A marking aerosol was successfully generated with the steam-tetraethylene glycol mixture from breadboard system hardware. A compact 25 lb/f thrust (nominal) H2O2 rocket chamber was the key component of the system which produced the required steam by catalytic decomposition of the supplied H2O2.

  1. Decoupled direct tracking control system based on use of a virtual track for multilayer disk with a separate guide layer

    NASA Astrophysics Data System (ADS)

    Tanaka, Yukinobu; Ogata, Takeshi; Imagawa, Seiji

    2015-09-01

    We developed a decoupled direct tracking control system for multilayer optical disk that uses a separate guide layer. Data marks are recorded on a recording layer immediately above the guide layer by using two spatially separated spots with different wavelengths. Accurate data mark recording requires that the relative positions of the corresponding spots on the recording layer and guide layer are maintained. However, a disk tilt can shift their relative positions and cause previously recorded data marks to be overwritten. Additionally, a two-input/two-output control system is susceptible to mutual interference phenomenon between the two outputs, which can destabilize tracking control. A tracking control system based on use of data marks previously recorded as a virtual track has been developed that prevents spot shifting and mutual interference even if the disk tilt reaches 0.7°, thereby preventing overwriting.

  2. Reducing aberration effect of Fourier transform lens by modifying Fourier spectrum of diffractive optical element in beam shaping optical system.

    PubMed

    Zhang, Fang; Zhu, Jing; Song, Qiang; Yue, Weirui; Liu, Jingdan; Wang, Jian; Situ, Guohai; Huang, Huijie

    2015-10-20

    In general, Fourier transform lenses are considered as ideal in the design algorithms of diffractive optical elements (DOEs). However, the inherent aberrations of a real Fourier transform lens disturb the far field pattern. The difference between the generated pattern and the expected design will impact the system performance. Therefore, a method for modifying the Fourier spectrum of DOEs without introducing other optical elements to reduce the aberration effect of the Fourier transform lens is proposed. By applying this method, beam shaping performance is improved markedly for the optical system with a real Fourier transform lens. The experiments carried out with a commercial Fourier transform lens give evidence for this method. The method is capable of reducing the system complexity as well as improving its performance.

  3. Beyond sequencing: optical mapping of DNA in the age of nanotechnology and nanoscopy.

    PubMed

    Levy-Sakin, Michal; Ebenstein, Yuval

    2013-08-01

    Next generation sequencing (NGS) is revolutionizing all fields of biological research but it fails to extract the full range of information associated with genetic material. Optical mapping of DNA grants access to genetic and epigenetic information on individual DNA molecules up to ∼1 Mbp in length. Fluorescent labeling of specific sequence motifs, epigenetic marks and other genomic information on individual DNA molecules generates a high content optical barcode along the DNA. By stretching the DNA to a linear configuration this barcode may be directly visualized by fluorescence microscopy. We discuss the advances of these methods in light of recent developments in nano-fabrication and super-resolution optical imaging (nanoscopy) and review the latest achievements of optical mapping in the context of genomic analysis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Applications of Optical Coherence Tomography in Pediatric Clinical Neuroscience

    PubMed Central

    Avery, Robert A.; Rajjoub, Raneem D.; Trimboli-Heidler, Carmelina; Waldman, Amy T.

    2015-01-01

    For nearly two centuries, the ophthalmoscope has permitted examination of the retina and optic nerve—the only axons directly visualized by the physician. The retinal ganglion cells project their axons, which travel along the innermost retina to form the optic nerve, marking the beginning of the anterior visual pathway. Both the structure and function of the visual pathway are essential components of the neurologic examination as it can be involved in numerous acquired, congenital and genetic central nervous system conditions. The development of optical coherence tomography now permits the pediatric neuroscientist to visualize and quantify the optic nerve and retinal layers with unprecedented resolution. As optical coherence tomography becomes more accessible and integrated into research and clinical care, the pediatric neuroscientist may have the opportunity to utilize and/or interpret results from this device. This review describes the basic technical features of optical coherence tomography and highlights its potential clinical and research applications in pediatric clinical neuroscience including optic nerve swelling, optic neuritis, tumors of the visual pathway, vigabatrin toxicity, nystagmus, and neurodegenerative conditions. PMID:25803824

  5. Applications of optical coherence tomography in pediatric clinical neuroscience.

    PubMed

    Avery, Robert A; Rajjoub, Raneem D; Trimboli-Heidler, Carmelina; Waldman, Amy T

    2015-04-01

    For nearly two centuries, the ophthalmoscope has permitted examination of the retina and optic nerve-the only axons directly visualized by the physician. The retinal ganglion cells project their axons, which travel along the innermost retina to form the optic nerve, marking the beginning of the anterior visual pathway. Both the structure and function of the visual pathway are essential components of the neurologic examination as it can be involved in numerous acquired, congenital and genetic central nervous system conditions. The development of optical coherence tomography now permits the pediatric neuroscientist to visualize and quantify the optic nerve and retinal layers with unprecedented resolution. As optical coherence tomography becomes more accessible and integrated into research and clinical care, the pediatric neuroscientist may have the opportunity to utilize and/or interpret results from this device. This review describes the basic technical features of optical coherence tomography and highlights its potential clinical and research applications in pediatric clinical neuroscience including optic nerve swelling, optic neuritis, tumors of the visual pathway, vigabatrin toxicity, nystagmus, and neurodegenerative conditions. Georg Thieme Verlag KG Stuttgart · New York.

  6. Fiber optic gyroscopes for vehicle navigation systems

    NASA Astrophysics Data System (ADS)

    Kumagai, Tatsuya; Soekawa, Hirokazu; Yuhara, Toshiya; Kajioka, Hiroshi; Oho, Shigeru; Sonobe, Hisao

    1994-03-01

    Fiber optic gyroscopes (FOGs) have been developed for vehicle navigation systems and are used in Toyota Motor Corporation models Mark II, Chaser and Cresta in Japan. Use of FOGs in these systems requires high reliability under a wide range of conditions, especially in a temperature range between -40 and 85 degree(s)C. In addition, a high cost-performance ratio is needed. We have developed optical and electrical systems that are inexpensive and can perform well. They are ready to be mass-produced. FOGs have already been installed in luxury automobiles, and will soon be included in more basic vehicles. We have developed more inexpensive FOGs for this purpose.

  7. Correction of the exciton Bohr radius in monolayer transition metal dichalcogenides

    NASA Astrophysics Data System (ADS)

    Li, Run-Ze; Dong, Xi-Ying; Li, Zhi-Qing; Wang, Zi-Wu

    2018-07-01

    We theoretically investigate the correction of exciton Bohr radius in monolayer transition metal dichalcogenides (TMDCs) on different polar substrates arising from the exciton-optical phonon coupling, in which both the intrinsic longitudinal optical phonon and surface optical phonon modes couple with the exciton are taken into account. We find that the exciton Bohr radius is enlarged markedly due to these coupling. Moreover, it can be changed on a large scale by modulating the polarizability of polar substrate and the internal distance between the monolayer TMDCs and polar substrate. Theoretical result provides a potential explanation for the variation of the exciton Bohr radius in experimental measurement.

  8. Amplitude and intensity spatial interferometry; Proceedings of the Meeting, Tucson, AZ, Feb. 14-16, 1990

    NASA Technical Reports Server (NTRS)

    Breckinridge, Jim B. (Editor)

    1990-01-01

    Attention is given to such topics as ground interferometers, space interferometers, speckle-based and interferometry-based astronomical observations, adaptive and atmospheric optics, speckle techniques, and instrumentation. Particular papers are presented concerning recent progress on the IR Michelson array; the IOTA interferometer project; a space interferometer concept for the detection of extrasolar earth-like planets; IR speckle imaging at Palomar; optical diameters of stars measured with the Mt. Wilson Mark III interferometer; the IR array camera for interferometry with the cophased Multiple Mirror Telescope; optimization techniques appliesd to the bispectrum of one-dimensional IR astronomical speckle data; and adaptive optical iamging for extended objects.

  9. BOOK REVIEW: Infrared Thermal Imaging: Fundamentals, Research and Applications Infrared Thermal Imaging: Fundamentals, Research and Applications

    NASA Astrophysics Data System (ADS)

    Planinsic, Gorazd

    2011-09-01

    Ten years ago, a book with a title like this would be interesting only to a narrow circle of specialists. Thanks to rapid advances in technology, the price of thermal imaging devices has dropped sharply, so they have, almost overnight, become accessible to a wide range of users. As the authors point out in the preface, the growth of this area has led to a paradoxical situation: now there are probably more infrared (IR) cameras sold worldwide than there are people who understand the basic physics behind them and know how to correctly interpret the colourful images that are obtained with these devices. My experience confirms this. When I started using the IR camera during lectures on the didactics of physics, I soon realized that I needed more knowledge, which I later found in this book. A wide range of potential readers and topical areas provides a good motive for writing a book such as this one, but it also represents a major challenge for authors, as compromises in the style of writing and choice of topics are required. The authors of this book have successfully achieved this, and indeed done an excellent job. This book addresses a wide range of readers, from engineers, technicians, and physics and science teachers in schools and universities, to researchers and specialists who are professionally active in the field. As technology in this area has made great progress in recent times, this book is also a valuable guide for those who opt to purchase an infrared camera. Chapters in this book could be divided into three areas: the fundamentals of IR thermal imaging and related physics (two chapters); IR imaging systems and methods (two chapters) and applications, including six chapters on pedagogical applications; IR imaging of buildings and infrastructure, industrial applications, microsystems, selected topics in research and industry, and selected applications from other fields. All chapters contain numerous colour pictures and diagrams, and a rich list of relevant literature. Let's devote a few more words to the section on pedagogical applications. It is the usual perception that the use of IR cameras for educational purposes is limited primarily to help visualize processes in thermodynamics such as heat conduction, evaporation, radiation and convection. In this book the authors show that the range of pedagogical applications of IR cameras is much wider. They describe concrete examples (from the descriptions it is clear that the authors have performed all experiments themselves) from mechanics (friction, inelastic collisions), electromagnetism (eddy currents, thermoelectric effect, analysis of standing waves in the microwave oven), optics (specular and diffuse reflection, wave optics in the IR region) and modern physics (selective absorption in gases). Readers who may want to repeat the experiments will appreciate the colour IR photos that are equipped with temperature scales from which one may learn which settings to use in order to achieve the best visibility of the phenomena to be observed. As said earlier, the decision to write a book for a wide range of readers requires authors to make certain compromises. The inclusion of interpretations and explanations at a basic level will certainly be welcomed by some readers, but due to the limited space some simplifications of this type of content were inevitable. Readers who might be put off by these simplifications should bear in mind that there are few authors who describe specialized topics such as this one and devote so much space to fundamentals. One can only wish that future authors of similar books will try to meet the standards set by this one.

  10. Factors influencing movement probabilities of big brown bats (Eptesicus fuscus) in buildings

    USGS Publications Warehouse

    Ellison, L.E.; O'Shea, T.J.; Neubaum, D.J.; Bowen, R.A.

    2007-01-01

    We investigated movements of female big brown bats (Eptesicus fuscus) roosting in maternity colonies in buildings in Fort Collins, Colorado (USA), during the summers of 2002, 2003, and 2005. This behavior can be of public health concern where bats that may carry diseases (e.g., rabies) move among buildings occupied by people. We used passive integrated transponders (PIT tags) to mark individual bats and hoop PIT readers at emergence points to passively monitor the use of building roosts by marked adult females on a daily basis during the lactation phase of reproduction. Multi-strata models were used to examine movements among roosts in relation to ambient temperatures and ectoparasite loads. Our results suggest that high ambient temperatures influence movements. Numbers of mites (Steatonyssus occidentalis) did not appear to influence movements of female bats among building roosts. In an urban landscape, periods with unusually hot conditions are accompanied by shifting of bats to different buildings or segments of buildings, and this behavior may increase the potential for contact with people in settings where, in comparison to their more regularly used buildings, the bats may be more likely to be of public concern as nuisances or health risks. ?? 2007 by the Ecological Society of America.

  11. ROCView: prototype software for data collection in jackknife alternative free-response receiver operating characteristic analysis

    PubMed Central

    Thompson, J; Hogg, P; Thompson, S; Manning, D; Szczepura, K

    2012-01-01

    ROCView has been developed as an image display and response capture (IDRC) solution to image display and consistent recording of reader responses in relation to the free-response receiver operating characteristic paradigm. A web-based solution to IDRC for observer response studies allows observations to be completed from any location, assuming that display performance and viewing conditions are consistent with the study being completed. The simplistic functionality of the software allows observations to be completed without supervision. ROCView can display images from multiple modalities, in a randomised order if required. Following registration, observers are prompted to begin their image evaluation. All data are recorded via mouse clicks, one to localise (mark) and one to score confidence (rate) using either an ordinal or continuous rating scale. Up to nine “mark-rating” pairs can be made per image. Unmarked images are given a default score of zero. Upon completion of the study, both true-positive and false-positive reports can be downloaded and adapted for analysis. ROCView has the potential to be a useful tool in the assessment of modality performance difference for a range of imaging methods. PMID:22573294

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colbert, C.; Moles, D.R.

    This paper reports that the authors developed for the Air Force the Mark VI Personal Identity Verifier (PIV) for controlling access to a fixed or mobile ICBM site, a computer terminal, or mainframe. The Mark VI records the digitized silhouettes of four fingers of each hand on an AT and T smart card. Like fingerprints, finger shapes, lengths, and widths constitute an unguessable biometric password. A Security Officer enrolls an authorized person who places each hand, in turn, on a backlighted panel. An overhead scanning camera records the right and left hand reference templates on the smart card. The Securitymore » Officer adds to the card: name, personal identification number (PIN), and access restrictions such as permitted days of the week, times of day, and doors. To gain access, cardowner inserts card into a reader slot and places either hand on the panel. Resulting access template is matched to the reference template by three sameness algorithms. The final match score is an average of 12 scores (each of the four fingers, matched for shape, length, and width), expressing the degree of sameness. (A perfect match would score 100.00.) The final match score is compared to a predetermined score (threshold), generating an accept or reject decision.« less

  13. Testing a dual-fluorescence assay to monitor the viability of filamentous cyanobacteria.

    PubMed

    Johnson, Tylor J; Hildreth, Michael B; Gu, Liping; Zhou, Ruanbao; Gibbons, William R

    2015-06-01

    Filamentous cyanobacteria are currently being engineered to produce long-chain organic compounds, including 3rd generation biofuels. Because of their filamentous morphology, standard methods to quantify viability (e.g., plate counts) are not possible. This study investigated a dual-fluorescence assay based upon the LIVE/DEAD® BacLight™ Bacterial Viability Kit to quantify the percent viability of filamentous cyanobacteria using a microplate reader in a high throughput 96-well plate format. The manufacturer's protocol calls for an optical density normalization step to equalize the numbers of viable and non-viable cells used to generate calibration curves. Unfortunately, the isopropanol treatment used to generate non-viable cells released a blue pigment that altered absorbance readings of the non-viable cell solution, resulting in an inaccurate calibration curve. Thus we omitted this optical density normalization step, and carefully divided cell cultures into two equal fractions before the isopropanol treatment. While the resulting calibration curves had relatively high correlation coefficients, their use in various experiments resulted in viability estimates ranging from below 0% to far above 100%. We traced this to the apparent inaccuracy of the propidium iodide (PI) dye that was to stain only non-viable cells. Through further analysis via microplate reader, as well as confocal and wide-field epi-fluorescence microscopy, we observed non-specific binding of PI in viable filamentous cyanobacteria. While PI will not work for filamentous cyanobacteria, it is possible that other fluorochrome dyes could be used to selectively stain non-viable cells. This will be essential in future studies for screening mutants and optimizing photobioreactor system performance for filamentous cyanobacteria. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. An Optically Stimulated Luminescence Uranium Enrichment Monitor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Steven D.; Tanner, Jennifer E.; Simmons, Kevin L.

    The Pacific Northwest National Laboratory (PNNL) has pioneered the use of Optically Stimulated Luminescence (OSL) technology for use in personnel dosimetry and high dose radiation processing dosimetry. PNNL has developed and patented an alumina-based OSL dosimeter that is being used by the majority of medical X-ray and imaging technicians worldwide. PNNL has conceived of using OSL technology to passively measure the level of UF6 enrichment by attaching the prototype OSL monitor to pipes containing UF6 gas within an enrichment facility. The prototype OSL UF6 monitor utilizes a two-element approach with the first element open and unfiltered to measure both themore » low energy and high energy gammas from the UF6, while the second element utilizes a 3-mm thick tungsten filter to eliminate the low energy gammas and pass only the high energy gammas from the UF6. By placing a control monitor in the room away from the UF6 pipes and other ionizing radiation sources, the control readings can be subtracted from the UF6 pipe monitor measurements. The ratio of the shielded to the unshielded net measurements provides a means to estimate the level of uranium enrichment. PNNL has replaced the commercially available MicroStar alumina-based dosimeter elements with a composite of polyethylene plastic, high-Z glass powder, and BaFBr:Eu OSL phosphor powder at various concentrations. The high-Z glass was added in an attempt to raise the average “Z” of the composite dosimeter and increase the response. Additionally, since BaFBr:Eu OSL phosphor is optimally excited and emits light at different wavelengths compared to alumina, the commercially available MicroStar reader was modified for reading BaFBr:Eu in a parallel effort to increase reader sensitivity. PNNL will present the design and performance of our novel OSL uranium enrichment monitor based on a combination of laboratory and UF6 test loop measurements. PNNL will also report on the optimization effort to achieve the highest possible performance from both the OSL enrichment monitor and the new custom OSL reader modified for this application. This project has been supported by the US Department of Energy’s National Nuclear Security Administration’s Office of Dismantlement and Transparency (DOE/NNSA/NA-241).« less

  15. Mark-forming simulations of phase-change land/groove disks

    NASA Astrophysics Data System (ADS)

    Nishi, Yoshiko; Shimano, Takeshi; Kando, Hidehiko

    2000-09-01

    The track pitches of optical discs have become so narrow that it is comparable to the wavelength of laser beam. Finite-difference time-domain (FDTD) simulation, based on vector diffraction analysis, can predict the propagation of light more accurately than scalar analysis, when the size of media texture becomes sub-micron order. The authors applied FDTD simulation to land-and-groove optical disc models, and found out that the effects of 3D geometry is not negligible in analyzing the energy absorption of light inside the land- and-groove multi-layered media. The electromagnetic field in the media does not have the same intensity distribution as the incident beam. Furthermore, the heat conduction inside the media depends on the disc geometry, so the beam spots centered on land and groove makes different effects in heating the recording layers. That is, the spatial and historical profile of temperature requires 3D analysis for both incident light absorption and heat conduction. The difference in temperature profiles is applied to the phase change simulator to see the writing process of the marks in land and groove. We have integrated three simulators: FDTD analysis, heat conduction and phase change simulation. These simulators enabled to evaluate the differences in mark forming process between land and groove.

  16. Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system

    DOE PAGES

    Chumbley, Scott; Zhang, Song; Morris, Max; ...

    2016-11-16

    Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markingsmore » that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.« less

  17. Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chumbley, Scott; Zhang, Song; Morris, Max

    Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markingsmore » that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.« less

  18. Reader performance in visual assessment of breast density using visual analogue scales: Are some readers more predictive of breast cancer?

    NASA Astrophysics Data System (ADS)

    Rayner, Millicent; Harkness, Elaine F.; Foden, Philip; Wilson, Mary; Gadde, Soujanya; Beetles, Ursula; Lim, Yit Y.; Jain, Anil; Bundred, Sally; Barr, Nicky; Evans, D. Gareth; Howell, Anthony; Maxwell, Anthony; Astley, Susan M.

    2018-03-01

    Mammographic breast density is one of the strongest risk factors for breast cancer, and is used in risk prediction and for deciding appropriate imaging strategies. In the Predicting Risk Of Cancer At Screening (PROCAS) study, percent density estimated by two readers on Visual Analogue Scales (VAS) has shown a strong relationship with breast cancer risk when assessed against automated methods. However, this method suffers from reader variability. This study aimed to assess the performance of PROCAS readers using VAS, and to identify those most predictive of breast cancer. We selected the seven readers who had estimated density on over 6,500 women including at least 100 cancer cases, analysing their performance using multivariable logistic regression and Receiver Operator Characteristic (ROC) analysis. All seven readers showed statistically significant odds ratios (OR) for cancer risk according to VAS score after adjusting for classical risk factors. The OR was greatest for reader 18 at 1.026 (95% Cl 1.018-1.034). Adjusted Area Under the ROC Curves (AUCs) were statistically significant for all readers, but greatest for reader 14 at 0.639. Further analysis of the VAS scores for these two readers showed reader 14 had higher sensitivity (78.0% versus 42.2%), whereas reader 18 had higher specificity (78.0% versus 46.0%). Our results demonstrate individual differences when assigning VAS scores; one better identified those with increased risk, whereas another better identified low risk individuals. However, despite their different strengths, both readers showed similar predictive abilities overall. Standardised training for VAS may improve reader variability and consistency of VAS scoring.

  19. Intraoperative neuropathology of glioma recurrence: cell detection and classification

    NASA Astrophysics Data System (ADS)

    Abas, Fazly S.; Gokozan, Hamza N.; Goksel, Behiye; Otero, Jose J.; Gurcan, Metin N.

    2016-03-01

    Intraoperative neuropathology of glioma recurrence represents significant visual challenges to pathologists as they carry significant clinical implications. For example, rendering a diagnosis of recurrent glioma can help the surgeon decide to perform more aggressive resection if surgically appropriate. In addition, the success of recent clinical trials for intraoperative administration of therapies, such as inoculation with oncolytic viruses, may suggest that refinement of the intraoperative diagnosis during neurosurgery is an emerging need for pathologists. Typically, these diagnoses require rapid/STAT processing lasting only 20-30 minutes after receipt from neurosurgery. In this relatively short time frame, only dyes, such as hematoxylin and eosin (H and E), can be implemented. The visual challenge lies in the fact that these patients have undergone chemotherapy and radiation, both of which induce cytological atypia in astrocytes, and pathologists are unable to implement helpful biomarkers in their diagnoses. Therefore, there is a need to help pathologists differentiate between astrocytes that are cytologically atypical due to treatment versus infiltrating, recurrent, neoplastic astrocytes. This study focuses on classification of neoplastic versus non-neoplastic astrocytes with the long term goal of providing a better neuropathological computer-aided consultation via classification of cells into reactive gliosis versus recurrent glioma. We present a method to detect cells in H and E stained digitized slides of intraoperative cytologic preparations. The method uses a combination of the `value' component of the HSV color space and `b*' component of the CIE L*a*b* color space to create an enhanced image that suppresses the background while revealing cells on an image. A composite image is formed based on the morphological closing of the hue-luminance combined image. Geometrical and textural features extracted from Discrete Wavelet Frames and combined to classify cells into neoplastic and non-neoplastic categories. Experimental results show that there is a strong consensus between the proposed method's cell detection markings with those of the pathologist's. Experiments on 48 images from six patients resulted in F1-score as high as 87.48%, 88.08% and 86.12% for Reader 1, Reader 2 and the reader consensus, respectively. Classification results showed that for both readers, binary classification tree and support vector machine performed the best with F1-scores ranging 0.92 to 0.94.

  20. 53BP1 is a reader of the DNA damage-induced H2A Lys15 ubiquitin mark

    PubMed Central

    Fradet-Turcotte, Amélie; Canny, Marella D.; Escribano-Díaz, Cristina; Orthwein, Alexandre; Leung, Charles C.Y.; Huang, Hao; Landry, Marie-Claude; Kitevski-LeBlanc, Julianne; Noordermeer, Sylvie M.; Sicheri, Frank; Durocher, Daniel

    2014-01-01

    53BP1 (TP53BP1) is a chromatin-associated factor that promotes immunoglobulin class switching and DNA double-strand break (DSB) repair by non-homologous end joining. To accomplish its function in DNA repair, 53BP1 accumulates at DSB sites downstream of the RNF168 ubiquitin ligase. How ubiquitin recruits 53BP1 to break sites remains enigmatic since its relocalization involves recognition of H4 Lys20 (H4K20) methylation by its Tudor domain. Here we elucidate how 53BP1 is recruited to the chromatin that flanks DSB sites. We show that 53BP1 recognizes mono-nucleosomes containing dimethylated H4K20 (H4K20me2) and H2A ubiquitylated on Lys15 (H2AK15ub), the latter being a product of RNF168 action on chromatin. 53BP1 binds to nucleosomes minimally as a dimer using its previously characterized methyl-lysine-binding Tudor domain and a C-terminal extension, termed the ubiquitylation-dependent recruitment (UDR) motif, which interacts with the epitope formed by H2AK15ub and its surrounding residues on the H2A tail. 53BP1 is therefore a bivalent histone modification reader that recognizes a histone “code” produced by DSB signaling. PMID:23760478

  1. Electron-beam lithography for micro and nano-optical applications

    NASA Technical Reports Server (NTRS)

    Wilson, Daniel W.; Muller, Richard E.; Echternach, Pierre M.

    2005-01-01

    Direct-write electron-beam lithography has proven to be a powerful technique for fabricating a variety of micro- and nano-optical devices. Binary E-beam lithography is the workhorse technique for fabricating optical devices that require complicated precision nano-scale features. We describe a bi-layer resist system and virtual-mark height measurement for improving the reliability of fabricating binary patterns. Analog E-beam lithography is a newer technique that has found significant application in the fabrication of diffractive optical elements. We describe our techniques for fabricating analog surface-relief profiles in E-beam resist, including some discussion regarding overcoming the problems of resist heating and charging. We also describe a multiple-field-size exposure scheme for suppression of field-stitch induced ghost diffraction orders produced by blazed diffraction gratings on non-flat substrates.

  2. Diffractive micro-optical element with nonpoint response

    NASA Astrophysics Data System (ADS)

    Soifer, Victor A.; Golub, Michael A.

    1993-01-01

    Common-use diffractive lenses have microrelief zones in the form of simple rings that provide only an optical power but do not contain any image information. They have a point-image response under point-source illumination. We must use a more complicated non-point response to focus a light beam into different light marks, letter-type images as well as for optical pattern recognition. The current presentation describes computer generation of diffractive micro- optical elements with complicated curvilinear zones of a regular piecewise-smooth structure and grey-level or staircase phase microrelief. The manufacture of non-point response elements uses the steps of phase-transfer calculation and orthogonal-scan masks generation or lithographic glass etching. Ray-tracing method is shown to be applicable in this task. Several working samples of focusing optical elements generated by computer and photolithography are presented. Using the experimental results we discuss here such applications as laser branding.

  3. Directions for rf-controlled intelligent microvalve

    NASA Astrophysics Data System (ADS)

    Enderling, Stefan; Varadan, Vijay K.; Abbott, Derek

    2001-03-01

    In this paper, we consider the novel concept of a Radio Frequency (RF) controllable microvalve for different medical applications. Wireless communication via a Surface Acoustic Wave Identification-mark (SAW ID-tag) is used to control, drive and locate the microvalve inside the human body. The energy required for these functions is provided by RF pulses, which are transmitted to the valve and back by a reader/transmitter system outside of the body. These RF bursts are converted into Surface Acoustic Waves (SAWs), which propagate along the piezoelectric actuator material of the microvalve. These waves cause deflections, which are employed to open and close the microvalve. We identified five important areas of application of the microvalve in biomedicine: 1) fertility control; 2) artificial venous valves; 3) flow cytometry; 4) drug delivery and 5) DNA mapping.

  4. Oliver Bloodstein: reflections on a career. Interview by Mark Onslow.

    PubMed

    Onslow, Mark

    2007-01-01

    Oliver Bloodstein arrived at the University of Iowa in 1941 to study under Wendell Johnson. There he began an influential career that included a seminal documentation of the development of stuttering, the development of the continuity hypothesis and the anticipatory struggle hypothesis, and the writing of five editions of the influential text "A Handbook on Stuttering." In this interview Dr. Bloodstein reflects on his remarkable and inspiring career, which continues today with his involvement in the preparation of a sixth edition of this text. The reader will: (1) describe the contribution to the field of stuttering made by Dr. Bloodstein; (2) discuss the career influences that led to his achievements; (3) know Dr. Bloodstein's current views on the cause of stuttering; and (4) identify the locations at which he worked during his career.

  5. Regenerative medicine technology applied to gastroenterology: current status and future perspectives.

    PubMed

    Orlando, Giuseppe

    2012-12-21

    This special issue of World Journal of Gastroenterology has been conceived to illustrate to gastroenterology operators the role that regenerative medicine (RM) will have in the progress of gastrointestinal (GI) medicine. RM is a multidisciplinary field aiming to replace, regenerate or repair diseased tissues or organs. The past decade has been marked by numerous ground-breaking achievements that led experts in the field to manufacture functional substitutes of relatively simple organs. This progress is paving the ground for investigations that aims to the bioengineering and regeneration of more complex organs like livers, pancreas and intestine. In this special issue, the reader will be introduced, hand-in-hand, to explore the field of RM and will be educated on the progress, pitfalls and promise of RM technologies as applied to GI medicine.

  6. Microcephalic Osteodysplastic Primordial Dwarfism, Type II: a Clinical Review.

    PubMed

    Bober, Michael B; Jackson, Andrew P

    2017-04-01

    This review will provide an overview of the microcephalic primordial dwarfism (MPD) class of disorders and provide the reader comprehensive clinical review with suggested care guidelines for patients with microcephalic osteodysplastic primordial dwarfism, type II (MOPDII). Over the last 15 years, significant strides have been made in the diagnosis, natural history, and management of MOPDII. MOPDII is the most common and well described form of MPD. The classic features of the MPD group are severe pre- and postnatal growth retardation, with marked microcephaly. In addition to these features, individuals with MOPDII have characteristic facies, skeletal dysplasia, abnormal dentition, and an increased risk for cerebrovascular disease and insulin resistance. Biallelic loss-of-function mutations in the pericentrin gene cause MOPDII, which is inherited in an autosomal recessive manner.

  7. Basic Research of Intrinsic Tamper Indication Markings Defined by Pulsed Laser Irradiation (Quad Chart).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moody, Neville R.

    Objective: We will research how short (ns) and ultrashort (fs) laser pulses interact with the surfaces of various materials to create complex color layers and morphological patterns. Method: We are investigating the site-specific, formation of microcolor features. Also, research includes a fundamental study of the physics underlying periodic ripple formation during femtosecond laser irradiation. Status of effort: Laser induced color markings were demonstrated on an increased number of materials (including metal thin films) and investigated for optical properties and microstructure. Technology that allows for marking curved surfaces (and large areas) has been implemented. We have used electro-magnetic solvers to modelmore » light-solid interactions leading to periodic surface ripple patterns. This includes identifying the roles of surface plasmon polaritons. Goals/Milestones: Research corrosion resistance of oxide color markings (salt spray, fog, polarization tests); Through modeling, investigate effects of multi-source scattering and interference on ripple patterns; Investigate microspectrophotometry for mapping color; and Investigate new methods for laser color marking curved surfaces and large areas.« less

  8. Methods and algorithms for optical coherence tomography-based angiography: a review and comparison

    NASA Astrophysics Data System (ADS)

    Zhang, Anqi; Zhang, Qinqin; Chen, Chieh-Li; Wang, Ruikang K.

    2015-10-01

    Optical coherence tomography (OCT)-based angiography is increasingly becoming a clinically useful and important imaging technique due to its ability to provide volumetric microvascular networks innervating tissue beds in vivo without a need for exogenous contrast agent. Numerous OCT angiography algorithms have recently been proposed for the purpose of contrasting microvascular networks. A general literature review is provided on the recent progress of OCT angiography methods and algorithms. The basic physics and mathematics behind each method together with its contrast mechanism are described. Potential directions for future technical development of OCT based angiography is then briefly discussed. Finally, by the use of clinical data captured from normal and pathological subjects, the imaging performance of vascular networks delivered by the most recently reported algorithms is evaluated and compared, including optical microangiography, speckle variance, phase variance, split-spectrum amplitude decorrelation angiography, and correlation mapping. It is found that the method that utilizes complex OCT signal to contrast retinal blood flow delivers the best performance among all the algorithms in terms of image contrast and vessel connectivity. The purpose of this review is to help readers understand and select appropriate OCT angiography algorithm for use in specific applications.

  9. SENSITIVITY AND SPECIFICITY OF DETECTING POLYPOIDAL CHOROIDAL VASCULOPATHY WITH EN FACE OPTICAL COHERENCE TOMOGRAPHY AND OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    de Carlo, Talisa E; Kokame, Gregg T; Kaneko, Kyle N; Lian, Rebecca; Lai, James C; Wee, Raymond

    2018-03-20

    Determine sensitivity and specificity of polypoidal choroidal vasculopathy (PCV) diagnosis with structural en face optical coherence tomography (OCT) and OCT angiography (OCTA). Retrospective review of the medical records of eyes diagnosed with PCV by indocyanine green angiography with review of diagnostic testing with structural en face OCT and OCTA by a trained reader. Structural en face OCT, cross-sectional OCT angiograms alone, and OCTA in its entirety were reviewed blinded to the findings of indocyanine green angiography and each other to determine if they could demonstrate the PCV complex. Sensitivity and specificity of PCV diagnosis was determined for each imaging technique using indocyanine green angiography as the ground truth. Sensitivity and specificity of structural en face OCT were 30.0% and 85.7%, of OCT angiograms alone were 26.8% and 96.8%, and of the entire OCTA were 43.9% and 87.1%, respectively. Sensitivity and specificity were improved for OCT angiograms and OCTA when looking at images taken within 1 month of PCV diagnosis. Sensitivity of detecting PCV was low using structural en face OCT and OCTA but specificity was high. Indocyanine green angiography remains the gold standard for PCV detection.

  10. Revealing Optical Components

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Optical Vector Analyzer (OVA) 1550 significantly reduces the time and cost of testing sophisticated optical components. The technology grew from the research Luna Technologies' Dr. Mark Froggatt conducted on optical fiber strain measurement while working at Langley Research Center. Dr. Froggatt originally developed the technology for non- destructive evaluation testing at Langley. The new technique can provide 10,000 independent strain measurements while adding less than 10 grams to the weight of the vehicle. The OVA is capable of complete linear characterization of single-mode optical components used in high- bit-rate applications. The device can test most components over their full range in less than 30 seconds, compared to the more than 20 minutes required by other testing methods. The dramatically shortened measurement time results in increased efficiency in final acceptance tests of optical devices, and the comprehensive data produced by the instrument adds considerable value for component consumers. The device eliminates manufacturing bottlenecks, while reducing labor costs and wasted materials during production.

  11. Understanding Reading through the Eyes of Third-Grade Struggling Readers

    ERIC Educational Resources Information Center

    Wiggs, Christine E.

    2012-01-01

    Within the vast research base on struggling readers, very few studies address the nature of struggling readers from their own perspectives; that is, how struggling readers experience reading instruction. The purpose of this qualitative case study research was to gain a deeper understanding of how three third-grade struggling readers viewed…

  12. Defense Automation Resources Management Manual

    DTIC Science & Technology

    1988-09-01

    Electronic Command Signals Programmer, Plugboard Programmers Punch, Card Punch, Paper Tape Reader, Character Reader-Generator, Time Cards Reader...Multiplexor-Shift Register Group Multiplier Panel Control, Plugboard Panel, Interconnection, Digital Computer Panel, Meter-Attenuator, Tape Recorder PC Cards...Perforator, Tape Plug-In Unit Potentiometer, Coefficient, Analog Computer Programmer, Plugboard Punch, Paper Tape Racks Reader, Time Code Reader

  13. Examining Readers' Evaluations of Objectivity and Bias in News Discourse

    ERIC Educational Resources Information Center

    Cramer, Peter; Eisenhart, Christopher

    2014-01-01

    Readers' objectivity and bias evaluations of news texts were investigated in order to better understand the process by which readers make these kinds of judgments and the evidence on which they base them. Readers were primed to evaluate news texts for objectivity and bias, and their selections and metacommentary were analyzed. Readers detected…

  14. Readers' Readings: Applications of Reader-Response Theory.

    ERIC Educational Resources Information Center

    Steiner, Linda

    In the interest of applying reader response theory to journalism this paper posits that readers of newspapers, like readers of literature, take an active role in making meaning from the articles they read, rather than passively accepting news as a finished, static product. Additionally, it proposes that journalism textbooks pay little attention to…

  15. A smartphone client-server teleradiology system for primary diagnosis of acute stroke.

    PubMed

    Mitchell, J Ross; Sharma, Pranshu; Modi, Jayesh; Simpson, Mark; Thomas, Monroe; Hill, Michael D; Goyal, Mayank

    2011-05-06

    Recent advances in the treatment of acute ischemic stroke have made rapid acquisition, visualization, and interpretation of images a key factor for positive patient outcomes. We have developed a new teleradiology system based on a client-server architecture that enables rapid access to interactive advanced 2-D and 3-D visualization on a current generation smartphone device (Apple iPhone or iPod Touch, or an Android phone) without requiring patient image data to be stored on the device. Instead, a server loads and renders the patient images, then transmits a rendered frame to the remote device. Our objective was to determine if a new smartphone client-server teleradiology system is capable of providing accuracies and interpretation times sufficient for diagnosis of acute stroke. This was a retrospective study. We obtained 120 recent consecutive noncontrast computed tomography (NCCT) brain scans and 70 computed tomography angiogram (CTA) head scans from the Calgary Stroke Program database. Scans were read by two neuroradiologists, one on a medical diagnostic workstation and an iPod or iPhone (hereafter referred to as an iOS device) and the other only on an iOS device. NCCT brain scans were evaluated for early signs of infarction, which includes early parenchymal ischemic changes and dense vessel sign, and to exclude acute intraparenchymal hemorrhage and stroke mimics. CTA brain scans were evaluated for any intracranial vessel occlusion. The interpretations made on an iOS device were compared with those made at a workstation. The total interpretation times were recorded for both platforms. Interrater agreement was assessed. True positives, true negatives, false positives, and false negatives were obtained, and sensitivity, specificity, and accuracy of detecting the abnormalities on the iOS device were computed. The sensitivity, specificity, and accuracy of detecting intraparenchymal hemorrhage were 100% using the iOS device with a perfect interrater agreement (kappa=1). The sensitivity, specificity, and accuracy of detecting acute parenchymal ischemic change were 94.1%, 100%, and 98.09% respectively for reader 1 and 97.05%, 100%, and 99.04% for reader 2 with nearly perfect interrater agreement (kappa=.8). The sensitivity, specificity, and accuracy of detecting dense vessel sign were 100%, 95.4%, and 96.19% respectively for reader 1 and 72.2%, 100%, and 95.23% for reader 2 using the iOS device with a good interrater agreement (kappa=.69). The sensitivity, specificity, and accuracy of detecting vessel occlusion on CT angiography scans were 94.4%, 100%, and 98.46% respectively for both readers using the iOS device, with perfect interrater agreement (kappa=1). No significant difference (P<.05) was noted in the interpretation time between the workstation and iOS device. The smartphone client-server teleradiology system appears promising and may have the potential to allow urgent management decisions in acute stroke. However, this study was retrospective, involved relatively few patient studies, and only two readers. Generalizing conclusions about its clinical utility, especially in other diagnostic use cases, should not be made until additional studies are performed. ©J Ross Mitchell, Pranshu Sharma, Jayesh Modi, Mark Simpson, Monroe Thomas, Michael D. Hill, Mayank Goyal.

  16. Neptune and Titan Observed with Keck Telescope Adaptive Optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Max, C.E.; Macintosh, B.A.; Gibbard, S.

    2000-05-05

    The authors report on observations taken during engineering science validation time using the new adaptive optics system at the 10-m Keck II Telescope. They observe Neptune and Titan at near-infrared wavelengths. These objects are ideal for adaptive optics imaging because they are bright and small, yet have many diffraction-limited resolution elements across their disks. In addition Neptune and Titan have prominent physical features, some of which change markedly with time. They have observed infrared-bright storms on Neptune, and very low-albedo surface regions on Titan, Saturn's largest moon, Spatial resolution on Neptune and Titan was 0.05-0.06 and 0.04-0.05 arc sec, respectively.

  17. Use of a scanning optical profilometer for toolmark characterization

    NASA Astrophysics Data System (ADS)

    Chumbley, L. S.; Eisenmann, D. J.; Morris, M.; Zhang, S.; Craft, J.; Fisher, C.; Saxton, A.

    2009-05-01

    An optical profilometer has been used to obtain 3-dimensional data for use in two research projects concerning toolmark quantification and identification. In the first study quantitative comparisons between toolmarks made using data from the optical system proved superior to similar data obtained using a stylus profilometer. In the second study the ability of the instrument to obtain accurate data from two surfaces intersecting at a high angle (approximately 90 degrees) is demonstrated by obtaining measurements from the tip of a flat screwdriver. The data obtained was used to produce a computer generated "virtual tool," which was then employed to create "virtual tool marks." How these experiments were conducted and the results obtained will be presented and discussed.

  18. Bone metastases in castration-resistant prostate cancer: associations between morphologic CT patterns, glycolytic activity, and androgen receptor expression on PET and overall survival.

    PubMed

    Vargas, Hebert Alberto; Wassberg, Cecilia; Fox, Josef J; Wibmer, Andreas; Goldman, Debra A; Kuk, Deborah; Gonen, Mithat; Larson, Steven M; Morris, Michael J; Scher, Howard I; Hricak, Hedvig

    2014-04-01

    To compare the features of bone metastases at computed tomography (CT) to tracer uptake at fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) and fluorine 18 16β-fluoro-5-dihydrotestosterone (FDHT) PET and to determine associations between these imaging features and overall survival in men with castration-resistant prostate cancer. This is a retrospective study of 38 patients with castration-resistant prostate cancer. Two readers independently evaluated CT, FDG PET, and FDHT PET features of bone metastases. Associations between imaging findings and overall survival were determined by using univariate Cox proportional hazards regression. In 38 patients, reader 1 detected 881 lesions and reader 2 detected 867 lesions. Attenuation coefficients at CT correlated inversely with FDG (reader 1: r = -0.3007; P < .001; reader 2: r = -0.3147; P < .001) and FDHT (reader 1: r = -0.2680; P = .001; reader 2: r = -0.3656; P < .001) uptake. The number of lesions on CT scans was significantly associated with overall survival (reader 1: hazard ratio [HR], 1.025; P = .05; reader 2: HR, 1.021; P = .04). The numbers of lesions on FDG and FDHT PET scans were significantly associated with overall survival for reader 1 (HR, 1.051-1.109; P < .001) and reader 2 (HR, 1.026-1.082; P ≤ .009). Patients with higher FDHT uptake (lesion with the highest maximum standardized uptake value) had significantly shorter overall survival (reader 1: HR, 1.078; P = .02; reader 2: HR, 1.092; P = .02). FDG uptake intensity was not associated with overall survival (reader 1, P = .65; reader 2, P = .38). In patients with castration-resistant prostate cancer, numbers of bone lesions on CT, FDG PET, and FDHT PET scans and the intensity of FDHT uptake are significantly associated with overall survival. RSNA, 2013

  19. Bone Metastases in Castration-Resistant Prostate Cancer: Associations between Morphologic CT Patterns, Glycolytic Activity, and Androgen Receptor Expression on PET and Overall Survival

    PubMed Central

    Wassberg, Cecilia; Fox, Josef J.; Wibmer, Andreas; Goldman, Debra A.; Kuk, Deborah; Gonen, Mithat; Larson, Steven M.; Morris, Michael J.; Scher, Howard I.; Hricak, Hedvig

    2014-01-01

    Purpose To compare the features of bone metastases at computed tomography (CT) to tracer uptake at fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) and fluorine 18 16β-fluoro-5-dihydrotestosterone (FDHT) PET and to determine associations between these imaging features and overall survival in men with castration-resistant prostate cancer. Materials and Methods This is a retrospective study of 38 patients with castration-resistant prostate cancer. Two readers independently evaluated CT, FDG PET, and FDHT PET features of bone metastases. Associations between imaging findings and overall survival were determined by using univariate Cox proportional hazards regression. Results In 38 patients, reader 1 detected 881 lesions and reader 2 detected 867 lesions. Attenuation coefficients at CT correlated inversely with FDG (reader 1: r = −0.3007; P < .001; reader 2: r = −0.3147; P < .001) and FDHT (reader 1: r = −0.2680; P = .001; reader 2: r = −0.3656; P < .001) uptake. The number of lesions on CT scans was significantly associated with overall survival (reader 1: hazard ratio [HR], 1.025; P = .05; reader 2: HR, 1.021; P = .04). The numbers of lesions on FDG and FDHT PET scans were significantly associated with overall survival for reader 1 (HR, 1.051–1.109; P < .001) and reader 2 (HR, 1.026–1.082; P ≤ .009). Patients with higher FDHT uptake (lesion with the highest maximum standardized uptake value) had significantly shorter overall survival (reader 1: HR, 1.078; P = .02; reader 2: HR, 1.092; P = .02). FDG uptake intensity was not associated with overall survival (reader 1, P = .65; reader 2, P = .38). Conclusion In patients with castration-resistant prostate cancer, numbers of bone lesions on CT, FDG PET, and FDHT PET scans and the intensity of FDHT uptake are significantly associated with overall survival. © RSNA, 2013 PMID:24475817

  20. Concurrent photolytic degradation of aqueous methylmercury and dissolved organic matter

    USGS Publications Warehouse

    Fleck, Jacob A.; Gill, Gary W.; Bergamaschi, Brian A.; Kraus, Tamara E.C.; Downing, Bryan D.; Alpers, Charles N.

    2014-01-01

    Monomethyl mercury (MeHg) is a potent neurotoxin that threatens ecosystem viability and human health. In aquatic systems, the photolytic degradation of MeHg (photodemethylation) is an important component of the MeHg cycle. Dissolved organic matter (DOM) is also affected by exposure to solar radiation (light exposure) leading to changes in DOM composition that can affect its role in overall mercury (Hg) cycling. This study investigated changes in MeHg concentration, DOM concentration, and the optical signature of DOM caused by light exposure in a controlled field-based experiment using water samples collected from wetlands and rice fields. Filtered water from all sites showed a marked loss in MeHg concentration after light exposure. The rate of photodemethylation was 7.5 × 10-3 m2 mol-1 (s.d. 3.5 × 10-3) across all sites despite marked differences in DOM concentration and composition. Light exposure also caused changes in the optical signature of the DOM despite there being no change in DOM concentration, indicating specific structures within the DOM were affected by light exposure at different rates. MeHg concentrations were related to optical signatures of labile DOM whereas the percent loss of MeHg was related to optical signatures of less labile, humic DOM. Relationships between the loss of MeHg and specific areas of the DOM optical signature indicated that aromatic and quinoid structures within the DOM were the likely contributors to MeHg degradation, perhaps within the sphere of the Hg-DOM bond. Because MeHg photodegradation rates are relatively constant across freshwater habitats with natural Hg–DOM ratios, physical characteristics such as shading and hydrologic residence time largely determine the relative importance of photolytic processes on the MeHg budget in these mixed vegetated and open-water systems.

  1. Concurrent photolytic degradation of aqueous methylmercury and dissolved organic matter.

    PubMed

    Fleck, Jacob A; Gill, Gary; Bergamaschi, Brian A; Kraus, Tamara E C; Downing, Bryan D; Alpers, Charles N

    2014-06-15

    Monomethyl mercury (MeHg) is a potent neurotoxin that threatens ecosystem viability and human health. In aquatic systems, the photolytic degradation of MeHg (photodemethylation) is an important component of the MeHg cycle. Dissolved organic matter (DOM) is also affected by exposure to solar radiation (light exposure) leading to changes in DOM composition that can affect its role in overall mercury (Hg) cycling. This study investigated changes in MeHg concentration, DOM concentration, and the optical signature of DOM caused by light exposure in a controlled field-based experiment using water samples collected from wetlands and rice fields. Filtered water from all sites showed a marked loss in MeHg concentration after light exposure. The rate of photodemethylation was 7.5×10(-3)m(2)mol(-1) (s.d. 3.5×10(-3)) across all sites despite marked differences in DOM concentration and composition. Light exposure also caused changes in the optical signature of the DOM despite there being no change in DOM concentration, indicating specific structures within the DOM were affected by light exposure at different rates. MeHg concentrations were related to optical signatures of labile DOM whereas the percent loss of MeHg was related to optical signatures of less labile, humic DOM. Relationships between the loss of MeHg and specific areas of the DOM optical signature indicated that aromatic and quinoid structures within the DOM were the likely contributors to MeHg degradation, perhaps within the sphere of the Hg-DOM bond. Because MeHg photodegradation rates are relatively constant across freshwater habitats with natural Hg-DOM ratios, physical characteristics such as shading and hydrologic residence time largely determine the relative importance of photolytic processes on the MeHg budget in these mixed vegetated and open-water systems. Published by Elsevier B.V.

  2. Screen printed flexible radiofrequency identification tag for oxygen monitoring.

    PubMed

    Martínez-Olmos, A; Fernández-Salmerón, J; Lopez-Ruiz, N; Rivadeneyra Torres, A; Capitan-Vallvey, L F; Palma, A J

    2013-11-19

    In this work, a radiofrequency identification (RFID) tag with an optical indicator for the measurement of gaseous oxygen is described. It consists of an O2 sensing membrane of PtOEP together with a full electronic system for RFID communication, all printed on a flexible substrate. The membrane is excited by an LED at 385 nm wavelength and the intensity of the luminescence generated is registered by means of a digital color detector. The output data corresponding to the red coordinate of the RGB color space is directly related to the concentration of O2, and it is sent to a microcontroller. The RFID tag is designed and implemented by screen printing on a flexible substrate for the wireless transmission of the measurement to a remote reader. It can operate in both active and passive mode, obtaining the power supply from the electromagnetic waves of the RFID reader or from a small battery, respectively. This system has been fully characterized and calibrated including temperature drifts, showing a high-resolution performance that allows measurement of very low values of oxygen content. Therefore this system is perfectly suitable for its use in modified atmosphere packaging where the oxygen concentration is reduced below 2%. As the reading of the O2 concentration inside the envelope is carried out with an external RFID reader using wireless communication, there is no need for perforations for probes or wires, so the packaging remains completely closed. With the presented device, a limit of detection of 40 ppm and a resolution as low as 0.1 ppm of O2 can be reached with a low power consumption of 3.55 mA.

  3. Cannibalism versus funerary defleshing and disarticulation after a period of decay: comparisons of bone modifications from four prehistoric sites.

    PubMed

    Bello, Silvia M; Wallduck, Rosalind; Dimitrijević, Vesna; Živaljević, Ivana; Stringer, Chris B

    2016-12-01

    Humanly induced modifications on human and non-human bones from four archaeological sites of known funerary rituals (one interpreted as cannibalism and three interpreted as funerary defleshing and disarticulation after a period of decay) were analyzed to ascertain whether macromorphological and micromorphological characteristics of cut marks can be used to distinguish cannibalistic from secondary burial practices. Four collections were analyzed: the Magdalenian assemblage from Gough's Cave (UK) and the Mesolithic-Neolithic bone samples from Lepenski Vir, Padina and Vlasac (Serbia). A total of 647 cut marks (345 on human and 302 on non-human remains) were imaged and measured using an optical surface measurement system, the Alicona InfiniteFocus, housed at the Natural History Museum (London, UK). The frequency of cut marks at Gough's Cave exceeds 65%, while it is below 1% in the Serbian sites, and no human tooth marks and only one case of percussion damage have been observed on the three Serbian collections. The distribution of cut marks on human bones is comparable in the four assemblages. Cannibalized human remains, however, present a uniform cut mark distribution, which can be associated with disarticulation of persistent and labile articulations, and the scalping and filleting of muscles. For secondary burials where modification occurred after a period of decay, disarticulation marks are less common and the disarticulation of labile joints is rare. The micromorphometric analyses of cut marks on human and non-human remains suggest that cut marks produced when cleaning partially decayed bodies are significantly different from cut marks produced during butchery of fresh bodies. A distinction between cannibalism and secondary treatment of human bodies can be made based on frequency, distribution and micromorphometric characteristics of cut marks. © 2016 Wiley Periodicals, Inc.

  4. Wolfram syndrome: a clinicopathologic correlation

    PubMed Central

    Merchant, Saumil N.; Adams, Joe C.; Joseph, Jeffrey T.

    2009-01-01

    Wolfram syndrome or DIDMOAD (diabetes insipidus, diabetes mellitus, optic atrophy and deafness) is a neurodegenerative disorder characterized by diabetes mellitus and optic atrophy as well as diabetes insipidus and deafness in many cases. We report the post-mortem neuropathologic findings of a patient with Wolfram syndrome and correlate them with his clinical presentation. In the hypothalamus, neurons in the paraventricular and supraoptic nuclei were markedly decreased and minimal neurohypophyseal tissue remained in the pituitary. The pontine base and inferior olivary nucleus showed gross shrinkage and neuron loss, while the cerebellum was relatively unaffected. The visual system had moderate to marked loss of retinal ganglion neurons, commensurate loss of myelinated axons in the optic nerve, chiasm and tract, and neuron loss in the lateral geniculate nucleus but preservation of the primary visual cortex. The patient’s inner ear showed loss of the organ of Corti in the basal turn of the cochleae and mild focal atrophy of the stria vascularis. These findings correlated well with the patient’s high-frequency hearing loss. The pathologic findings correlated closely with the patient’s clinical symptoms and further support the concept of Wolfram syndrome as a neurodegenerative disorder. Our findings extend prior neuropathologic reports of Wolfram syndrome by providing contributions to our understanding of eye, inner ear and olivopontine pathology in this disease. PMID:19449020

  5. Optic cup segmentation: type-II fuzzy thresholding approach and blood vessel extraction

    PubMed Central

    Almazroa, Ahmed; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-01-01

    We introduce here a new technique for segmenting optic cup using two-dimensional fundus images. Cup segmentation is the most challenging part of image processing of the optic nerve head due to the complexity of its structure. Using the blood vessels to segment the cup is important. Here, we report on blood vessel extraction using first a top-hat transform and Otsu’s segmentation function to detect the curves in the blood vessels (kinks) which indicate the cup boundary. This was followed by an interval type-II fuzzy entropy procedure. Finally, the Hough transform was applied to approximate the cup boundary. The algorithm was evaluated on 550 fundus images from a large dataset, which contained three different sets of images, where the cup was manually marked by six ophthalmologists. On one side, the accuracy of the algorithm was tested on the three image sets independently. The final cup detection accuracy in terms of area and centroid was calculated to be 78.2% of 441 images. Finally, we compared the algorithm performance with manual markings done by the six ophthalmologists. The agreement was determined between the ophthalmologists as well as the algorithm. The best agreement was between ophthalmologists one, two and five in 398 of 550 images, while the algorithm agreed with them in 356 images. PMID:28515636

  6. Optic cup segmentation: type-II fuzzy thresholding approach and blood vessel extraction.

    PubMed

    Almazroa, Ahmed; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-01-01

    We introduce here a new technique for segmenting optic cup using two-dimensional fundus images. Cup segmentation is the most challenging part of image processing of the optic nerve head due to the complexity of its structure. Using the blood vessels to segment the cup is important. Here, we report on blood vessel extraction using first a top-hat transform and Otsu's segmentation function to detect the curves in the blood vessels (kinks) which indicate the cup boundary. This was followed by an interval type-II fuzzy entropy procedure. Finally, the Hough transform was applied to approximate the cup boundary. The algorithm was evaluated on 550 fundus images from a large dataset, which contained three different sets of images, where the cup was manually marked by six ophthalmologists. On one side, the accuracy of the algorithm was tested on the three image sets independently. The final cup detection accuracy in terms of area and centroid was calculated to be 78.2% of 441 images. Finally, we compared the algorithm performance with manual markings done by the six ophthalmologists. The agreement was determined between the ophthalmologists as well as the algorithm. The best agreement was between ophthalmologists one, two and five in 398 of 550 images, while the algorithm agreed with them in 356 images.

  7. Children and adults both see 'pirates' in 'parties': letter-position effects for developing readers and skilled adult readers.

    PubMed

    Paterson, Kevin B; Read, Josephine; McGowan, Victoria A; Jordan, Timothy R

    2015-03-01

    Developing readers often make anagrammatical errors (e.g. misreading pirates as parties), suggesting they use letter position flexibly during word recognition. However, while it is widely assumed that the occurrence of these errors decreases with increases in reading skill, empirical evidence to support this distinction is lacking. Accordingly, we compared the performance of developing child readers (aged 8-10 years) against the end-state performance of skilled adult readers in a timed naming task, employing anagrams used previously in this area of research. Moreover, to explore the use of letter position by developing readers and skilled adult readers more fully, we used anagrams which, to form another word, required letter transpositions over only interior letter positions, or both interior and exterior letter positions. The patterns of effects across these two anagram types for the two groups of readers were very similar. In particular, both groups showed similarly slowed response times (and developing readers increased errors) for anagrams requiring only interior letter transpositions but not for anagrams that required exterior letter transpositions. This similarity in the naming performance of developing readers and skilled adult readers suggests that the end-state skilled use of letter position is established earlier during reading development than is widely assumed. © 2014 John Wiley & Sons Ltd.

  8. Three Readers, Three Languages, Three Texts: The Strategic Reading of Multilingual and Multiliterate Readers

    ERIC Educational Resources Information Center

    Alsheikh, Negmeldin O.

    2011-01-01

    This case study investigates the metacognitive reading strategies of three advanced proficient trilingual readers whose native language is Hausa. The study examines the reading strategies employed by the three readers in English, French and Hausa. The aim of the study was to compare the reading strategy profiles of trilingual readers through…

  9. Struggling Readers: Assessment and Instruction in Grades K-6. Solving Problems in the Teaching of Literacy.

    ERIC Educational Resources Information Center

    Balajthy, Ernest; Lipa-Wade, Sally

    This book focuses on three distinct types of struggling readers that teachers will instantly recognize from their own classrooms--the "Catch-On Reader," the "Catch-Up Reader," and the "Stalled Reader." The book provides detailed case studies which bring to life the specific problems these students are likely to face…

  10. "True Wizardry": Readers Theatre in the Classroom. PEN 79.

    ERIC Educational Resources Information Center

    Robertson, Marion E.

    This article describes Readers Theater (a form of group storytelling in which two or more readers present a piece of literature by reading aloud from hand-held scripts) and advocates its use in the classroom. The paper's seven sections are as follows: (1) What is Readers Theater; (2) Readers Theater and Its Conventions (discussing scripts,…

  11. NaturalReader: A New Generation Text Reader

    ERIC Educational Resources Information Center

    Flood, Jacqueline

    2007-01-01

    NaturalReader (http://www.naturalreaders.com/) is a new generation text reader, which means that it reads any machine readable text using synthesized speech without having to copy and paste the selected text into the NaturalReader application window. It installs a toolbar directly into all of the Microsoft Office[TM] programs and uses a mini-board…

  12. EDITORIAL: Future developments

    NASA Astrophysics Data System (ADS)

    Lange, Wulf

    2004-02-01

    Some five years ago, Ennio Arimondo become Editor-in-Chief of Journal of Optics B: Quantum and Semiclassical Optics, following a change of title and other substantial changes. During that time he has established the journal as a prime platform for presenting scientific material in the field of quantum and semiclassical optics. By diligently incorporating new topics as they arose in neighbouring fields, he has contributed substantially towards creating permanent growth and has demonstrated the vitality of our branch of optics. It is a pleasure and an honour for me to assume now the role of the Editor-in-Chief and to succeed Ennio under these favourable circumstances. At present I do not see a need, nor even any justification, for fundamental changes in the editorial policy of the journal, and propose to follow the proven tradition of my successful predecessors. The journal has already adopted procedures for driving up the overall quality of published articles and, looking to the future, we expect to continue raising the scientific quality and international standing of the journal, coupled with a controlled growth in the number of pages published. Fortunately, there are no limitations for such qualitative improvements. I will seek to maintain and extend the high standards established by Ennio Arimondo, and before him by Paul Mandel, and to continue providing a high-quality product that attracts the best international authors and offers true value for the reader.

  13. Intravital microscopy: a novel tool to study cell biology in living animals.

    PubMed

    Weigert, Roberto; Sramkova, Monika; Parente, Laura; Amornphimoltham, Panomwat; Masedunskas, Andrius

    2010-05-01

    Intravital microscopy encompasses various optical microscopy techniques aimed at visualizing biological processes in live animals. In the last decade, the development of non-linear optical microscopy resulted in an enormous increase of in vivo studies, which have addressed key biological questions in fields such as neurobiology, immunology and tumor biology. Recently, few studies have shown that subcellular processes can be imaged dynamically in the live animal at a resolution comparable to that achieved in cell cultures, providing new opportunities to study cell biology under physiological conditions. The overall aim of this review is to give the reader a general idea of the potential applications of intravital microscopy with a particular emphasis on subcellular imaging. An overview of some of the most exciting studies in this field will be presented using resolution as a main organizing criterion. Indeed, first we will focus on those studies in which organs were imaged at the tissue level, then on those focusing on single cells imaging, and finally on those imaging subcellular organelles and structures.

  14. A Cool Sport Full of Physics

    NASA Astrophysics Data System (ADS)

    Haché, Alain

    2008-10-01

    Of all sports, ice hockey is possibly the one with the widest array of physics elements in it. The game provides many examples that can bring physics to life in the classroom. Ice hockey (or just "hockey" as many Canadians would say) sees athletes sliding on ice at high speeds and in various ways, shooting and slapping pucks, and colliding against each other. The interaction between the skate blade and the ice is a problem of great physical complexity. The question "Why is ice so slippery?" has puzzled generations of scientists and, surprisingly, clear answers have come relatively recently. There is even some optics involved in hockey: how many sports are watched behind tempered glass (or Plexiglas) windows? The optical and mechanical properties of these materials are worth a physics classroom discussion. In this paper, I will review a few topics discussed at length in my book The Physics of Hockey.1,2 Interested readers may also find additional articles on our website.3

  15. Compton camera imaging and the cone transform: a brief overview

    NASA Astrophysics Data System (ADS)

    Terzioglu, Fatma; Kuchment, Peter; Kunyansky, Leonid

    2018-05-01

    While most of Radon transform applications to imaging involve integrations over smooth sub-manifolds of the ambient space, lately important situations have appeared where the integration surfaces are conical. Three of such applications are single scatter optical tomography, Compton camera medical imaging, and homeland security. In spite of the similar surfaces of integration, the data and the inverse problems associated with these modalities differ significantly. In this article, we present a brief overview of the mathematics arising in Compton camera imaging. In particular, the emphasis is made on the overdetermined data and flexible geometry of the detectors. For the detailed results, as well as other approaches (e.g. smaller-dimensional data or restricted geometry of detectors) the reader is directed to the relevant publications. Only a brief description and some references are provided for the single scatter optical tomography. This work was supported in part by NSF DMS grants 1211463 (the first two authors), 1211521 and 141877 (the third author), as well as a College of Science of Texas A&M University grant.

  16. RFID Reader Antenna with Multi-Linear Polarization Diversity

    NASA Technical Reports Server (NTRS)

    Fink, Patrick; Lin, Greg; Ngo, Phong; Kennedy, Timothy; Rodriguez, Danny; Chu, Andrew; Broyan, James; Schmalholz, Donald

    2018-01-01

    This paper describes an RFID reader antenna that offers reduced polarization loss compared to that typically associated with reader-tag communications involving arbitrary relative orientation of the reader antenna and the tag.

  17. Is a "Phoenician" reading style superior to a "Chinese" reading style? Evidence from fourth graders.

    PubMed

    Bowey, Judith A

    2008-07-01

    This study compared normally achieving fourth-grade "Phoenician" readers, who identify nonwords significantly more accurately than they do exception words, with "Chinese" readers, who show the reverse pattern. Phoenician readers scored lower than Chinese readers on word identification, exception word reading, orthographic choice, spelling, reading comprehension, and verbal ability. When compared with normally achieving children who read nonwords and exception words equally well, Chinese readers scored as well as these children on word identification, regular word reading, orthographic choice, spelling, reading comprehension, phonological sensitivity, and verbal ability and scored better on exception word reading. Chinese readers also used rhyme-based analogies to read nonwords derived from high-frequency exception words just as often as did these children. As predicted, Phoenician and Chinese readers adopted somewhat different strategies in reading ambiguous nonwords constructed by analogy to high-frequency exception words. Phoenician readers were more likely than Chinese readers to read ambiguous monosyllabic nonwords via context-free grapheme-phoneme correspondences and were less likely to read disyllabic nonwords by analogy to high-frequency analogues. Although the Chinese reading style was more common than the Phoenician style in normally achieving fourth graders, there were similar numbers of poor readers with phonological dyslexia (identifying nonwords significantly more accurately than exception words) and surface dyslexia (showing the reverse pattern), although surface dyslexia was more common in the severely disabled readers. However, few of the poor readers showed pure patterns of phonological or surface dyslexia.

  18. Demonstration of Multi- and Single-Reader Sample Size Program for Diagnostic Studies software.

    PubMed

    Hillis, Stephen L; Schartz, Kevin M

    2015-02-01

    The recently released software Multi- and Single-Reader Sample Size Sample Size Program for Diagnostic Studies , written by Kevin Schartz and Stephen Hillis, performs sample size computations for diagnostic reader-performance studies. The program computes the sample size needed to detect a specified difference in a reader performance measure between two modalities, when using the analysis methods initially proposed by Dorfman, Berbaum, and Metz (DBM) and Obuchowski and Rockette (OR), and later unified and improved by Hillis and colleagues. A commonly used reader performance measure is the area under the receiver-operating-characteristic curve. The program can be used with typical common reader-performance measures which can be estimated parametrically or nonparametrically. The program has an easy-to-use step-by-step intuitive interface that walks the user through the entry of the needed information. Features of the software include the following: (1) choice of several study designs; (2) choice of inputs obtained from either OR or DBM analyses; (3) choice of three different inference situations: both readers and cases random, readers fixed and cases random, and readers random and cases fixed; (4) choice of two types of hypotheses: equivalence or noninferiority; (6) choice of two output formats: power for specified case and reader sample sizes, or a listing of case-reader combinations that provide a specified power; (7) choice of single or multi-reader analyses; and (8) functionality in Windows, Mac OS, and Linux.

  19. Electron irradiation response on Ge and Al-doped SiO 2 optical fibres

    NASA Astrophysics Data System (ADS)

    Yaakob, N. H.; Wagiran, H.; Hossain, I.; Ramli, A. T.; Bradley, D. A.; Hashim, S.; Ali, H.

    2011-05-01

    This paper describes the thermoluminescence response, sensitivity, stability and reproducibility of SiO 2 optical fibres with various electron energies and doses. The TL materials that comprise Al- and Ge-doped silica fibres were used in this experiment. The TL results are compared with those of the commercially available TLD-100. The doped SiO 2 optical fibres and TLD-100 are placed in a solid phantom and irradiated with 6, 9 and 12 MeV electron beams at doses ranging from 0.2 to 4.0 Gy using the LINAC at Hospital Sultan Ismail, Johor Bahru, Malaysia. It was found that the commercially available Al- and Ge-doped optical fibres have a linear dose-TL signal relationship. The intensity of TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre.

  20. Engaging Literacy: A Case Study in the Use of e-Reader Devices

    ERIC Educational Resources Information Center

    Lettenmaier, Kris

    2013-01-01

    The purpose of this case study was to determine to what extent e-readers affected struggling readers as a part of reading instruction at the middle school level to improve students' literacy skills of comprehension, fluency, and vocabulary, and to show how e-readers affected engagement and self-efficacy of struggling readers to read and use…

  1. Cognitive Processes in Discourse Comprehension: Passive Processes, Reader-Initiated Processes, and Evolving Mental Representations

    ERIC Educational Resources Information Center

    van den Broek, Paul; Helder, Anne

    2017-01-01

    As readers move through a text, they engage in various types of processes that, if all goes well, result in a mental representation that captures their interpretation of the text. With each new text segment the reader engages in passive and, at times, reader-initiated processes. These processes are strongly influenced by the readers'…

  2. How Do Fluent and Poor Readers' Endurance Differ in Reading?

    ERIC Educational Resources Information Center

    Bastug, Muhammet; Keskin, Hasan Kagan; Akyol, Mustafa

    2017-01-01

    It was observed in this research how endurance status of fluent readers and poor readers changed as the text became longer. 40 students of the primary school 4th-grade, 20 were fluent readers and other 20 were poor readers, participated in the research. A narrative text was utilised in the data collection process. Students' oral readings were…

  3. Laser marking of contrast images for optical read-out systems

    NASA Astrophysics Data System (ADS)

    Yulmetova, O. S.; Tumanova, M. A.

    2017-11-01

    In the present study the formation of contrast images that provide functionality of optical read-out systems is considered. The image contrast is determined by the difference of reflection coefficients of the beryllium surface covered with titanium nitride film (TiN) formed by physical vapor deposition and the image created on it by laser oxidation. Two ways of contrast variation are studied: by regulating both TiN reflection coefficient during vapor deposition and the reflection coefficient of the image obtained with the laser. The test results show the efficiency of the proposed approach.

  4. The Impact of Morphological Awareness on Word Reading and Dictation in Chinese Early Adolescent Readers With and Without Dyslexia.

    PubMed

    Kalindi, Sylvia Chanda; Chung, Kevin Kien Hoa

    2018-01-01

    This study investigated the role of morphological awareness in understanding Chinese word reading and dictation among Chinese-speaking adolescent readers in Hong Kong as well as the cognitive-linguistic profile of early adolescent readers with dyslexia. Fifty-four readers with dyslexia in Grades 5 and 6 were compared with 54 chronological age-matched (CA) typical readers on the following measures of cognitive-linguistic and literacy skills: morphological awareness, phonological awareness, visual-orthographic knowledge, rapid naming, vocabulary knowledge, verbal short-term memory (STM), Chinese word reading, and dictation (or spelling). The results indicated that early adolescent readers with dyslexia performed less well than the typical readers on all cognitive-linguistic and literacy measures except the phonological measures. Both groups' scores showed substantial correlations between morphological awareness and Chinese word reading and dictation. Visual-orthographic knowledge and rapid naming were also associated with dictation in early adolescent readers with and without dyslexia, respectively. Moderated multiple regression analyses further revealed that morphological awareness and rapid naming explained unique variance in word reading and dictation for the readers with dyslexia and typical readers separately after controlling readers' age and group effect. These results highlight the potential importance of morphological awareness and rapid naming in Chinese word reading and writing in Chinese early adolescents' literacy development and impairment.

  5. An Analysis of the Reading Strategies Used by Deaf and Hearing Adults: Similarities and Differences in Phonological Processing and Metacognition

    ERIC Educational Resources Information Center

    Silvestri, Julia A.

    2016-01-01

    This study is a mixed methods analysis of reading processes and language experiences of deaf and hearing readers. The sample includes four groups each with fifteen adults--identified as: deaf/high-achieving readers, deaf/struggling/non-academic readers, hearing/high-achieving readers, and hearing/non-academic readers. The purpose of this study is…

  6. Visual assessment of breast density using Visual Analogue Scales: observer variability, reader attributes and reading time

    NASA Astrophysics Data System (ADS)

    Ang, Teri; Harkness, Elaine F.; Maxwell, Anthony J.; Lim, Yit Y.; Emsley, Richard; Howell, Anthony; Evans, D. Gareth; Astley, Susan; Gadde, Soujanya

    2017-03-01

    Breast density is a strong risk factor for breast cancer and has potential use in breast cancer risk prediction, with subjective methods of density assessment providing a strong relationship with the development of breast cancer. This study aims to assess intra- and inter-observer variability in visual density assessment recorded on Visual Analogue Scales (VAS) among trained readers, and examine whether reader age, gender and experience are associated with assessed density. Eleven readers estimated the breast density of 120 mammograms on two occasions 3 years apart using VAS. Intra- and inter-observer agreement was assessed with Intraclass Correlation Coefficient (ICC) and variation between readers visualised on Bland-Altman plots. The mean scores of all mammograms per reader were used to analyse the effect of reader attributes on assessed density. Excellent intra-observer agreement (ICC>0.80) was found in the majority of the readers. All but one reader had a mean difference of <10 percentage points from the first to the second reading. Inter-observer agreement was excellent for consistency (ICC 0.82) and substantial for absolute agreement (ICC 0.69). However, the 95% limits of agreement for pairwise differences were -6.8 to 15.7 at the narrowest and 0.8 to 62.3 at the widest. No significant association was found between assessed density and reader age, experience or gender, or with reading time. Overall, the readers were consistent in their scores, although some large variations were observed. Reader evaluation and targeted training may alleviate this problem.

  7. The N170 ERP component differs in laterality, distribution, and association with continuous reading measures for deaf and hearing readers.

    PubMed

    Emmorey, Karen; Midgley, Katherine J; Kohen, Casey B; Sehyr, Zed Sevcikova; Holcomb, Phillip J

    2017-11-01

    The temporo-occipitally distributed N170 ERP component is hypothesized to reflect print-tuning in skilled readers. This study investigated whether skilled deaf and hearing readers (matched on reading ability, but not phonological awareness) exhibit similar N170 patterns, given their distinct experiences learning to read. Thirty-two deaf and 32 hearing adults viewed words and symbol strings in a familiarity judgment task. In the N170 epoch (120-240ms) hearing readers produced greater negativity for words than symbols at left hemisphere (LH) temporo-parietal and occipital sites, while deaf readers only showed this asymmetry at occipital sites. Linear mixed effects regression was used to examine the influence of continuous measures of reading, spelling, and phonological skills on the N170 (120-240ms). For deaf readers, better reading ability was associated with a larger N170 over the right hemisphere (RH), but for hearing readers better reading ability was associated with a smaller RH N170. Better spelling ability was related to larger occipital N170s in deaf readers, but this relationship was weak in hearing readers. Better phonological awareness was associated with smaller N170s in the LH for hearing readers, but this association was weaker and in the RH for deaf readers. The results support the phonological mapping hypothesis for a left-lateralized temporo-parietal N170 in hearing readers and indicate that skilled reading is characterized by distinct patterns of neural tuning to print in deaf and hearing adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Deaf Readers’ Response to Syntactic Complexity: Evidence from Self-Paced Reading

    PubMed Central

    Traxler, Matthew J.; Corina, David P.; Morford, Jill P.; Hafer, Sarah; Hoversten, Liv J.

    2013-01-01

    This study was designed to determine the feasibility of using self-paced reading methods to study deaf readers and to assess how deaf readers respond to two syntactic manipulations. Three groups of participants read the test sentences: deaf readers, hearing monolingual English readers, and hearing bilingual readers whose second language was English. In Experiment 1, participants read sentences containing subject relative or object relative clauses. The test sentences contained semantic information that influences on-line processing outcomes (Traxler et al., 2002; 2005). All of the participant groups had greater difficulty processing sentences containing object relative clauses. This difficulty was reduced when helpful semantic cues were present. In Experiment 2, participants read active voice and passive voice sentences. The sentences were processed similarly by all three groups. Comprehension accuracy was higher in hearing readers than in deaf readers. Within deaf readers, native signers read the sentences faster and comprehended them to a higher degree than did non-native signers. These results indicate that self-paced reading is a useful method for studying sentence interpretation among deaf readers. PMID:23868696

  9. An analysis of the reading strategies used by adult and student deaf readers.

    PubMed

    Banner, Alyssa; Wang, Ye

    2011-01-01

    The purpose of this study was to identify and examine effective reading strategies used by adult deaf readers compared with student deaf readers. There were a total of 11 participants: 5 deaf adults ranging from 27 to 36 years and 6 deaf students ranging from 16 to 20 years. Assessment methods included interview and think-aloud procedures in which individuals were interrupted 3 times during the reading of a text to answer questions about their internal cognitive processes. It was found that both student and adult groups had highly skilled readers who demonstrated higher level reading strategies and less skilled readers who demonstrated lower level strategies, and only the highest skilled reader demonstrated both breadth and depth of strategies in all three categories: "constructing meaning," "monitoring and improving comprehension," and "evaluating comprehension." The study contributes evidence toward two identified gaps in the existing body of research: (a) the lack of investigation into the reading strategies utilized by deaf readers in text comprehension and (b) the overemphasis of most research on studying less skilled deaf readers while overlooking highly proficient deaf readers.

  10. Developing Critical Thinking in Undergraduate Courses: A Philosophical Approach.

    ERIC Educational Resources Information Center

    Kalman, Calvin S.

    2002-01-01

    Examines how 20th century philosophers of science have influenced current physics educational research. Examines the introduction of a study of these philosophers in several courses, including the calculus-based introductory physics course on optics and modern physics. Concludes that students seem to have made a marked improvement in their…

  11. (abstract) Cryogenic Telescope Test Facility

    NASA Technical Reports Server (NTRS)

    Luchik, T. S.; Chave, R. G.; Nash, A. E.

    1995-01-01

    An optical test Dewar is being constructed with the unique capability to test mirrors of diameter less than or equal to 1 m, f less than or equal to 6, at temperatures from 300 to 4.2 K with a ZYGO Mark IV interferometer. The design and performance of this facility will be presented.

  12. Optical Properties of Metals.

    DTIC Science & Technology

    1983-07-15

    9. T. Holstein, Phys. Rev. 88, 1427 (1952); Phys. Rev. 96, 535 (1954). 10. A.B. Pippard, Proc. Roy. Soc. A191 , 370 (1947). 11. H.E. Bennett, J.M...process in a dust-free environment. Any dust, particulate matter, residual stains , or water marks will replicate .ust as well as the surface

  13. 77 FR 54935 - Government-Owned Inventions, Available for Licensing.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ...: Systems and Methods for Peak-Seeking Control Polarization-Induced Fading in Fiber-Optic System; NASA Case... FURTHER INFORMATION CONTACT: Mark W. Homer, Patent Counsel, NASA Management Office--JPL, 4800 Oak Grove...; NASA Case No. NPO-47580-1: Energy Harvesting Systems and Methods of Assembling Same; NASA Case No. NPO...

  14. Using Randomized Clinical Trials to Determine the Impact of Reading Intervention on Struggling Adolescent Readers: Reports of Research from Five Nationally Funded Striving Readers Grants

    ERIC Educational Resources Information Center

    Loadman, William; Sprague, Kim; Hamilton, Jennifer; Coffey, Deb; Faddis, Bonnie

    2010-01-01

    In 2005, the U.S. Department of Education awarded eight Striving Readers grants to projects around the country. The goal of Striving Readers is to improve literacy skills and achievement for struggling readers in middle and high school and to increase the research base using randomized clinical research to address improvement in adolescent…

  15. Utility of CT Findings in the Diagnosis of Cecal Volvulus.

    PubMed

    Dane, Bari; Hindman, Nicole; Johnson, Evan; Rosenkrantz, Andrew B

    2017-10-01

    The objective of our study was to assess the utility of CT features in the diagnosis of cecal volvulus. Forty-three patients undergoing CT for cecal volvulus and with surgical or clinical follow-up were included. Two radiologists (11 years and 1 year of experience) evaluated CT examinations for the following: whirl sign, abnormal cecal position, "bird beak" sign, severe cecal distention, mesenteric engorgement, a newly described "central appendix" sign (defined as abnormal appendix position near midline), and overall impression for cecal volvulus. Univariable and multivariable assessments were performed. Patients with CT examinations in which the appendix was not visible were excluded from calculations involving the central appendix sign. Fifty-one percent (n = 22) of patients had cecal volvulus. All CT findings were significantly more common in patients with cecal volvulus (p < 0.01) other than mesenteric engorgement for reader 1 (p = 0.332). Readers 1 and 2 identified the central appendix sign in 92.9% and 92.3% of patients with volvulus versus in 37.5 and 31.1% of patients without volvulus. The whirl sign exhibited a sensitivity for cecal volvulus of 90.9% for reader 1 and 95.5% for reader 2, and a specificity of 61.9% for both readers. Abnormal cecal position exhibited a sensitivity of 90.0% for reader 1 and 100.0% for reader 2 and a specificity of 66.7% and 38.1%. The bird beak sign exhibited a sensitivity of 86.4% for reader 1 and 100.0% for reader 2 and a specificity of 85.7% and 71.4%. Severe cecal distention exhibited a sensitivity of 100.0% for both readers and a specificity of 81.0% and 61.9%. Mesenteric engorgement exhibited a sensitivity of 40.9% for reader 1 and 100.0% for reader 2 and a specificity of 76.2% and 71.4%. The central appendix sign exhibited a sensitivity of 92.9% for reader 1 and 92.3% for reader 2 and a specificity of 62.5% and 68.8%. Overall impression exhibited a sensitivity of 100.0% for both readers and a specificity of 76.2% and 57.1%. At multivariable analysis, the AUC for cecal volvulus ranged from 0.787 to 0.931, and the whirl sign was an independent predictor of volvulus for both readers (p ≤ 0.014); the central appendix sign was also an independent predictor in patients with a visualized appendix for reader 2 (p ≤ 0.001). CT exhibited high diagnostic performance and very high sensitivity for cecal volvulus. The whirl sign was a significant independent predictor of volvulus for both readers.

  16. The Role of Esophageal Hypersensitivity in Functional Esophageal Disorders.

    PubMed

    Farmer, Adam D; Ruffle, James K; Aziz, Qasim

    2017-02-01

    The Rome IV diagnostic criteria delineates 5 functional esophageal disorders which include functional chest pain, functional heartburn, reflux hypersensitivity, globus, and functional dysphagia. These are a heterogenous group of disorders which, despite having characteristic symptom profiles attributable to esophageal pathology, fail to demonstrate any structural, motility or inflammatory abnormalities on standard clinical testing. These disorders are associated with a marked reduction in patient quality of life, not least considerable healthcare resources. Furthermore, the pathophysiology of these disorders is incompletely understood. In this narrative review we provide the reader with an introductory primer to the structure and function of esophageal perception, including nociception that forms the basis of the putative mechanisms that may give rise to symptoms in functional esophageal disorders. We also discuss the provocative techniques and outcome measures by which esophageal hypersensitivity can be established.

  17. MAWRID: A Model of Arabic Word Reading in Development.

    PubMed

    Saiegh-Haddad, Elinor

    2017-07-01

    This article offers a model of Arabic word reading according to which three conspicuous features of the Arabic language and orthography shape the development of word reading in this language: (a) vowelization/vocalization, or the use of diacritical marks to represent short vowels and other features of articulation; (b) morphological structure, namely, the predominance and transparency of derivational morphological structure in the linguistic and orthographic representation of the Arabic word; and (c) diglossia, specifically, the lexical and lexico-phonological distance between the spoken and the standard forms of Arabic words. It is argued that the triangulation of these features governs the acquisition and deployment of reading mechanisms across development. Moreover, the difficulties that readers encounter in their journey from beginning to skilled reading may be better understood if evaluated within these language-specific features of Arabic language and orthography.

  18. Does early reading failure decrease children's reading motivation?

    PubMed

    Morgan, Paul L; Fuchs, Douglas; Compton, Donald L; Cordray, David S; Fuchs, Lynn S

    2008-01-01

    The authors used a pretest-posttest control group design with random assignment to evaluate whether early reading failure decreases children's motivation to practice reading. First, they investigated whether 60 first-grade children would report substantially different levels of interest in reading as a function of their relative success or failure in learning to read. Second, they evaluated whether increasing the word reading ability of 15 at-risk children would lead to gains in their motivation to read. Multivariate analyses of variance suggest marked differences in both motivation and reading practice between skilled and unskilled readers. However, bolstering at-risk children's word reading ability did not yield evidence of a causal relationship between early reading failure and decreased motivation to engage in reading activities. Instead, hierarchical regression analyses indicate a covarying relationship among early reading failure, poor motivation, and avoidance of reading.

  19. Isaac Newton learns Hebrew: Samuel Johnson's Nova cubi Hebræi tabella

    PubMed Central

    Joalland, Michael; Mandelbrote, Scott

    2016-01-01

    This article concerns the earliest evidence for Isaac Newton's use of Hebrew: a manuscript copy by Newton of part of a work intended to provide a reader of the Hebrew alphabet with the ability to identify or memorize more than 1000 words and to begin to master the conjugations of the Hebrew verb. In describing the content of this unpublished manuscript and establishing its source and original author for the first time, we suggest how and when Newton may have initially become acquainted with the language. Finally, basing our discussion in part on an examination of the reading marks that Newton left in the surviving copies of Hebrew grammars and lexicons that he owned, we will argue that his interest in Hebrew was not intended to achieve linguistic proficiency but remained limited to particular theological queries of singular concern.

  20. Regenerative medicine technology applied to gastroenterology: Current status and future perspectives

    PubMed Central

    Orlando, Giuseppe

    2012-01-01

    This special issue of World Journal of Gastroenterology has been conceived to illustrate to gastroenterology operators the role that regenerative medicine (RM) will have in the progress of gastrointestinal (GI) medicine. RM is a multidisciplinary field aiming to replace, regenerate or repair diseased tissues or organs. The past decade has been marked by numerous ground-breaking achievements that led experts in the field to manufacture functional substitutes of relatively simple organs. This progress is paving the ground for investigations that aims to the bioengineering and regeneration of more complex organs like livers, pancreas and intestine. In this special issue, the reader will be introduced, hand-in-hand, to explore the field of RM and will be educated on the progress, pitfalls and promise of RM technologies as applied to GI medicine. PMID:23322983

  1. Securing quality of camera-based biomedical optics

    NASA Astrophysics Data System (ADS)

    Guse, Frank; Kasper, Axel; Zinter, Bob

    2009-02-01

    As sophisticated optical imaging technologies move into clinical applications, manufacturers need to guarantee their products meet required performance criteria over long lifetimes and in very different environmental conditions. A consistent quality management marks critical components features derived from end-users requirements in a top-down approach. Careful risk analysis in the design phase defines the sample sizes for production tests, whereas first article inspection assures the reliability of the production processes. We demonstrate the application of these basic quality principles to camera-based biomedical optics for a variety of examples including molecular diagnostics, dental imaging, ophthalmology and digital radiography, covering a wide range of CCD/CMOS chip sizes and resolutions. Novel concepts in fluorescence detection and structured illumination are also highlighted.

  2. A silicon Brillouin laser

    NASA Astrophysics Data System (ADS)

    Otterstrom, Nils T.; Behunin, Ryan O.; Kittlaus, Eric A.; Wang, Zheng; Rakich, Peter T.

    2018-06-01

    Brillouin laser oscillators offer powerful and flexible dynamics as the basis for mode-locked lasers, microwave oscillators, and optical gyroscopes in a variety of optical systems. However, Brillouin interactions are markedly weak in conventional silicon photonic waveguides, stifling progress toward silicon-based Brillouin lasers. The recent advent of hybrid photonic-phononic waveguides has revealed Brillouin interactions to be one of the strongest and most tailorable nonlinearities in silicon. In this study, we have harnessed these engineered nonlinearities to demonstrate Brillouin lasing in silicon. Moreover, we show that this silicon-based Brillouin laser enters a regime of dynamics in which optical self-oscillation produces phonon linewidth narrowing. Our results provide a platform to develop a range of applications for monolithic integration within silicon photonic circuits.

  3. Reading Proficiency and Adaptability in Orthographic Processing: An Examination of the Effect of Type of Orthography Read on Brain Activity in Regular and Dyslexic Readers

    PubMed Central

    Bar-Kochva, Irit; Breznitz, Zvia

    2014-01-01

    Regular readers were found to adjust the routine of reading to the demands of processing imposed by different orthographies. Dyslexic readers may lack such adaptability in reading. This hypothesis was tested among readers of Hebrew, as Hebrew has two forms of script differing in phonological transparency. Event-related potentials were recorded from 24 regular and 24 dyslexic readers while they carried out a lexical decision task in these two forms of script. The two forms of script elicited distinct amplitudes and latencies at ∼165 ms after target onset, and these effects were larger in regular than in dyslexic readers. These early effects appeared not to be merely a result of the visual difference between the two forms of script (the presence of diacritics). The next effect of form of script was obtained on amplitudes elicited at latencies associated with orthographic-lexical processing and the categorization of stimuli, and these appeared earlier in regular readers (∼340 ms) than in dyslexic readers (∼400 ms). The behavioral measures showed inferior reading skills of dyslexic readers compared to regular readers in reading of both forms of script. Taken together, the results suggest that although dyslexic readers are not indifferent to the type of orthography read, they fail to adjust the routine of reading to the demands of processing imposed by both a transparent and an opaque orthography. PMID:24465844

  4. [Survey among readers of the Tijdschrift voor Psychiatrie].

    PubMed

    Brandt-Dominicus, J C; van Harten, P N

    2006-01-01

    The editorial board has defined the objectives of this journal as follows: to provide its readers with refreshing information, to report the results of scientific research and to build bridges between research and everyday practice. To find out what readers want and whether they support the board's objectives, and to use this information in planning the contents of future issues of the journal. All readers were invited to complete a questionnaire either on paper or via the website. Questionnaires were completed by 255 readers (response rate 5.7%). The average rating on a 5-point Likert scale was 3.8. Thematic issues and issues devoted to book reviews were given a high rating. There seems to be a demandfor evidence-based medicine, the inclusion of scientific results reported in other journals and practice-based articles. No significant differences were found between the views expressed by readers who had previously submitted an article for publication and those who had not, nor between Flemish readers and Dutch readers. The website was not visited very often. The Tijdschrift voor Psychiatrie is greatly appreciated by its readers. They are largely in agreement with the objectives formulated by the editorial board. Thematic issues are highly rated and many subjects are mentioned by the readers for future issues. The low response to the survey can affect its representativity. The editorial board will take readers' wishes into consideration when selecting material for future issues of the journal.

  5. Past tense marking in the spontaneous speech of preschool children who do and do not stutter.

    PubMed

    Bauman, Jessica; Hall, Nancy E; Wagovich, Stacy A; Weber-Fox, Christine M; Ratner, Nan Bernstein

    2012-12-01

    The aim of this study was to identify whether different patterns of errors exist in irregular past-tense verbs in children who stutter (CWS) and children who do not stutter (CWNS). Spontaneous language samples of thirty-one age- and gender-matched pairs of children (total N=62) between the ages of 24 months and 59 months were analyzed. Results indicated that children who do and do not stutter over-regularize irregular past-tense verbs (i.e., saying runned for ran) with comparable frequency. However, two nonsignificant trends which suggest possible intra-group differences were noted. First, irregular past tense verbs represented a greater portion of total verbs for CWS than for CWNS. Second, CWS appeared to double-mark (i.e., say ranned for ran) more often than CWNS. Results are discussed in light of theories about the acquisition of the irregular past-tense and about differences in language skills between CWS and CWNS. After reading this article, the reader will be able to: (a) summarize previous findings about connections between stuttering and language in CWS and CWNS; (b) describe similarities and differences between irregular past-tense verb use and errors in CWS and CWNS; (c) discuss possible connections between the declarative-procedural model and stuttering. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. EDITORIAL: Photorefractive materials and effects for photonics

    NASA Astrophysics Data System (ADS)

    Vlad, V. I.; Fazio, E.; Damzen, M.

    2003-11-01

    This special issue of Journal of Optics A: Pure and Applied Optics is devoted to a mature field of nonlinear optics: photorefractive materials and effects for photonics. Photorefractivity was discovered long time ago by A Ashkin et al in 1966 and since then much work has been performed to characterize the phenomenon and to apply it. Nevertheless, research in this field remain very active and productive, in both basic and applied directions. Some leading groups worldwide present their most up-to-date investigations of photorefractive materials and effects, as well as their applications in photonics. Thus, the papers in this issue report new results in three directions: photorefractive material researches, wave propagation (particularly solitons) through these nonlinear optical materials, and various applications and devices using photorefractive effects. The challenging goal of photorefractive material research is to find sensitive and fast materials for information transmission and processing. P M Johansen studies the fundamental problem of space--charge field formation in photorefractives. V Marinova et al show that light-induced properties of Ru-doped Bi12TiO20 (BTO) crystals has an extended sensitivity in the near infrared region. H A Al-Attar and O Taqatqa introduce a new photorefractive polymer composite for their interesting properties for optical data storage. R Ramos-Garcia et al perform measurements of absorption coefficient and refractive index changes in photorefractive quantum wells of GaAs. A Radoua et al characterize by two-wave mixing the photorefractive Ba0.77Ca0.23TiO3:Rh crystals (BCT) at 1.06 mum, and M K Balakirev et al study the photorefractive effect upon all optical poling of glass. Wave propagation and solitons are intensively studied in photorefractive crystals due to the possibility of obtaining steady-state spatial solitons, dynamic waveguiding and soliton interactions at low laser intensity. W Ramadan et al introduce a new procedure to obtain stationary self-confined beams at non-absorbed wavelengths in Bi12SiO20 (BSO). Two groups, C Weilnau and C Denz and Z Chen et al, investigate photorefractive solitons using partially coherent light beams. Waveguiding and interactions in photorefractive soliton arrays are demonstrated by R Delgado Macuil and M D Iturbe Castillo and by D Träger et al. V Matusevich et al show some aspects of fanning, self-focusing and self-defocusing in a photorefractive BCT crystal. Applications and devices are developing in hologram recording and storage, image processing, interferometry and optical phase conjugation in photorefractive materials. G Berger et al record non-volatile volume holograms in bismuth tellurite crystals. I de Oliveira and J Frejlich perform diffraction efficiency measurement in photorefractive thick volume holograms. Holography with photorefractive multiple quantum well devices is used by C Dunsby et al in high-speed wide-field coherence-gated imaging. A photorefractive fringe-locked running hologram is analysed by M C Barbosa and J Frejlich in three-dimensional space. Detection of small in-plane vibrations using the polarization self-modulation effect in GaP is performed by Y Iida et al. E Weidner et al design an interferometric camera with a wavefront buffer memory using a photorefractive crystal as the active medium. R Nicolaus et al investigate and optimize a pulsed ultraviolet image amplifier within a micro-marking system. C Gu et al apply unconventional photorefractive materials in fibre optic devices. Photorefractive phase conjugate mirrors are used by T Omatsu et al to obtain multi-watt picosecond pulses from a diode-pumped Nd:YVO4 amplifier with a diffraction-limited spatial profile, and V M Petrov et al design optical on-line controllable filters based on photorefractive crystals. We hope that this special issue of Journal of Optics A: Pure and Applied Optics will reflect the intense activity in the field of photorefractivity and will demonstrate to readers some of the actual directions of research in these topics. We express our full appreciation to the authors and we would like to thank the paper reviewers for their important role in the paper selection process. We acknowledge the Publisher, Claire Bedrock, and the technical staff of the journal for their support, dedication and energy, which made feasible this special issue.

  7. Optical Testing and Verification Methods for the James Webb Space Telescope Integrated Science Instrument Module Element

    NASA Technical Reports Server (NTRS)

    Antonille, Scott R.; Miskey, Cherie L.; Ohl, Raymond G.; Rohrbach, Scott O.; Aronstein, David L.; Bartoszyk, Andrew E.; Bowers, Charles W.; Cofie, Emmanuel; Collins, Nicholas R.; Comber, Brian J.; hide

    2016-01-01

    NASA's James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (40K). The JWST Observatory includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) that contains four science instruments (SI) and the fine guider. The SIs are mounted to a composite metering structure. The SI and guider units were integrated to the ISIM structure and optically tested at the NASA Goddard Space Flight Center as a suite using the Optical Telescope Element SIMulator (OSIM). OSIM is a full field, cryogenic JWST telescope simulator. SI performance, including alignment and wave front error, were evaluated using OSIM. We describe test and analysis methods for optical performance verification of the ISIM Element, with an emphasis on the processes used to plan and execute the test. The complexity of ISIM and OSIM drove us to develop a software tool for test planning that allows for configuration control of observations, associated scripts, and management of hardware and software limits and constraints, as well as tools for rapid data evaluation, and flexible re-planning in response to the unexpected. As examples of our test and analysis approach, we discuss how factors such as the ground test thermal environment are compensated in alignment. We describe how these innovative methods for test planning and execution and post-test analysis were instrumental in the verification program for the ISIM element, with enough information to allow the reader to consider these innovations and lessons learned in this successful effort in their future testing for other programs.

  8. Optical testing and verification methods for the James Webb Space Telescope Integrated Science Instrument Module element

    NASA Astrophysics Data System (ADS)

    Antonille, Scott R.; Miskey, Cherie L.; Ohl, Raymond G.; Rohrbach, Scott O.; Aronstein, David L.; Bartoszyk, Andrew E.; Bowers, Charles W.; Cofie, Emmanuel; Collins, Nicholas R.; Comber, Brian J.; Eichhorn, William L.; Glasse, Alistair C.; Gracey, Renee; Hartig, George F.; Howard, Joseph M.; Kelly, Douglas M.; Kimble, Randy A.; Kirk, Jeffrey R.; Kubalak, David A.; Landsman, Wayne B.; Lindler, Don J.; Malumuth, Eliot M.; Maszkiewicz, Michael; Rieke, Marcia J.; Rowlands, Neil; Sabatke, Derek S.; Smith, Corbett T.; Smith, J. Scott; Sullivan, Joseph F.; Telfer, Randal C.; Te Plate, Maurice; Vila, M. Begoña.; Warner, Gerry D.; Wright, David; Wright, Raymond H.; Zhou, Julia; Zielinski, Thomas P.

    2016-09-01

    NASA's James Webb Space Telescope (JWST) is a 6.5m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM), that contains four science instruments (SI) and the Fine Guidance Sensor (FGS). The SIs are mounted to a composite metering structure. The SIs and FGS were integrated to the ISIM structure and optically tested at NASA's Goddard Space Flight Center using the Optical Telescope Element SIMulator (OSIM). OSIM is a full-field, cryogenic JWST telescope simulator. SI performance, including alignment and wavefront error, was evaluated using OSIM. We describe test and analysis methods for optical performance verification of the ISIM Element, with an emphasis on the processes used to plan and execute the test. The complexity of ISIM and OSIM drove us to develop a software tool for test planning that allows for configuration control of observations, implementation of associated scripts, and management of hardware and software limits and constraints, as well as tools for rapid data evaluation, and flexible re-planning in response to the unexpected. As examples of our test and analysis approach, we discuss how factors such as the ground test thermal environment are compensated in alignment. We describe how these innovative methods for test planning and execution and post-test analysis were instrumental in the verification program for the ISIM element, with enough information to allow the reader to consider these innovations and lessons learned in this successful effort in their future testing for other programs.

  9. Evidence for Deficits in the Temporal Attention Span of Poor Readers

    PubMed Central

    Visser, Troy A. W.

    2014-01-01

    Background While poor reading is often associated with phonological deficits, many studies suggest that visual processing might also be impaired. In particular, recent research has indicated that poor readers show impaired spatial visual attention spans in partial and whole report tasks. Given the similarities between competition-based accounts for reduced visual attention span and similar explanations for impairments in sequential object processing, the present work examined whether poor readers show deficits in their “temporal attention span” – that is, their ability to rapidly and accurately process sequences of consecutive target items. Methodology/Principal Findings Poor and normal readers monitored a sequential stream of visual items for two (TT condition) or three (TTT condition) consecutive target digits. Target identification was examined using both unconditional and conditional measures of accuracy in order to gauge the overall likelihood of identifying a target and the likelihood of identifying a target given successful identification of previous items. Compared to normal readers, poor readers showed small but consistent deficits in identification across targets whether unconditional or conditional accuracy was used. Additionally, in the TTT condition, final-target conditional accuracy was poorer than unconditional accuracy, particularly for poor readers, suggesting a substantial cost arising from processing the previous two targets that was not present in normal readers. Conclusions/Significance Mirroring the differences found between poor and normal readers in spatial visual attention span, the present findings suggest two principal differences between the temporal attention spans of poor and normal readers. First, the consistent pattern of reduced performance across targets suggests increased competition amongst items within the same span for poor readers. Second, the steeper decline in final target performance amongst poor readers in the TTT condition suggests a reduction in the extent of their temporal attention span. PMID:24651313

  10. Evidence for deficits in the temporal attention span of poor readers.

    PubMed

    Visser, Troy A W

    2014-01-01

    While poor reading is often associated with phonological deficits, many studies suggest that visual processing might also be impaired. In particular, recent research has indicated that poor readers show impaired spatial visual attention spans in partial and whole report tasks. Given the similarities between competition-based accounts for reduced visual attention span and similar explanations for impairments in sequential object processing, the present work examined whether poor readers show deficits in their "temporal attention span"--that is, their ability to rapidly and accurately process sequences of consecutive target items. Poor and normal readers monitored a sequential stream of visual items for two (TT condition) or three (TTT condition) consecutive target digits. Target identification was examined using both unconditional and conditional measures of accuracy in order to gauge the overall likelihood of identifying a target and the likelihood of identifying a target given successful identification of previous items. Compared to normal readers, poor readers showed small but consistent deficits in identification across targets whether unconditional or conditional accuracy was used. Additionally, in the TTT condition, final-target conditional accuracy was poorer than unconditional accuracy, particularly for poor readers, suggesting a substantial cost arising from processing the previous two targets that was not present in normal readers. Mirroring the differences found between poor and normal readers in spatial visual attention span, the present findings suggest two principal differences between the temporal attention spans of poor and normal readers. First, the consistent pattern of reduced performance across targets suggests increased competition amongst items within the same span for poor readers. Second, the steeper decline in final target performance amongst poor readers in the TTT condition suggests a reduction in the extent of their temporal attention span.

  11. Reliability of semiquantitative assessment of osteophytes and subchondral cysts on tomosynthesis images by radiologists with different levels of expertise.

    PubMed

    Hayashi, Daichi; Xu, Li; Gusenburg, Jeffrey; Roemer, Frank W; Hunter, David J; Li, Ling; Guermazi, Ali

    2014-01-01

    We aimed to assess reliability of the evaluation of osteophytes and subchondral cysts on tomosynthesis images when read by radiologists with different levels of expertise. Forty subjects aged >40 years had both knees evaluated using tomosynthesis. Images were read by an "experienced" reader (musculoskeletal radiologist with prior experience) and an "inexperienced" reader (radiology resident with no prior experience). Readers graded osteophytes from 0 to 3 and noted the presence/absence of subchondral cysts in four locations of the tibiofemoral joint. Twenty knees were randomly selected and re-read. Inter- and intrareader reliabilities were calculated using overall exact percent agreement and weighted κ statistics. Diagnostic performance of the two readers was compared against magnetic resonance imaging readings by an expert reader (professor of musculoskeletal radiology). The experienced reader showed substantial intrareader reliability for graded reading of osteophytes (90%, κ=0.93), osteophyte detection (95%, κ=0.86) and cyst detection (95%, κ=0.83). The inexperienced reader showed perfect intrareader reliability for cyst detection (100%, κ=1.00) but intrareader reliability for graded reading (75%, κ=0.79) and detection (80%, κ=0.61) of osteophytes was lower than the experienced reader. Inter-reader reliability was 61% (κ=0.72) for graded osteophyte reading, 91% (κ=0.82) for osteophyte detection, and 88% (κ=0.66) for cyst detection. Diagnostic performance of the experienced reader was higher than the inexperienced reader regarding osteophyte detection (sensitivity range 0.74-0.95 vs. 0.54-0.75 for all locations) but diagnostic performance was similar for subchondral cysts. Tomosynthesis offers excellent intrareader reliability regardless of the reader experience, but experience is important for detection of osteophytes.

  12. Reliability of semiquantitative assessment of osteophytes and subchondral cysts on tomosynthesis images by radiologists with different levels of expertise

    PubMed Central

    Hayashi, Daichi; Xu, Li; Gusenburg, Jeffrey; Roemer, Frank W.; Hunter, David J.; Li, Ling; Guermazi, Ali

    2014-01-01

    PURPOSE We aimed to assess reliability of the evaluation of osteophytes and subchondral cysts on tomosynthesis images when read by radiologists with different levels of expertise. MATERIALS AND METHODS Forty subjects aged >40 years had both knees evaluated using tomosynthesis. Images were read by an “experienced” reader (musculoskeletal radiologist with prior experience) and an “inexperienced” reader (radiology resident with no prior experience). Readers graded osteophytes from 0 to 3 and noted the presence/absence of subchondral cysts in four locations of the tibiofemoral joint. Twenty knees were randomly selected and re-read. Inter- and intrareader reliabilities were calculated using overall exact percent agreement and weighted κ statistics. Diagnostic performance of the two readers was compared against magnetic resonance imaging readings by an expert reader (professor of musculoskeletal radiology). RESULTS The experienced reader showed substantial intrareader reliability for graded reading of osteophytes (90%, κ=0.93), osteophyte detection (95%, κ=0.86) and cyst detection (95%, κ=0.83). The inexperienced reader showed perfect intrareader reliability for cyst detection (100%, κ=1.00) but intrareader reliability for graded reading (75%, κ=0.79) and detection (80%, κ=0.61) of osteophytes was lower than the experienced reader. Inter-reader reliability was 61% (κ=0.72) for graded osteophyte reading, 91% (κ=0.82) for osteophyte detection, and 88% (κ=0.66) for cyst detection. Diagnostic performance of the experienced reader was higher than the inexperienced reader regarding osteophyte detection (sensitivity range 0.74–0.95 vs. 0.54–0.75 for all locations) but diagnostic performance was similar for subchondral cysts. CONCLUSION Tomosynthesis offers excellent intrareader reliability regardless of the reader experience, but experience is important for detection of osteophytes. PMID:24834489

  13. Optical and electrical properties of heavily indium-doped CdS around the semiconductor-metal phase transition

    NASA Astrophysics Data System (ADS)

    Broser, I.; Broser, R.; Birkicht, E.

    1990-04-01

    Heavily indium-doped CdS crystals are studied by comparing their optical and electrical properties. It is shown that in the near infrared spectral region for highly conducting crystals the correlation of electrical conductivity and optical effects can still be understood in the frame of the classical Drude-Lorentz model. Even for high doping the relaxation time τ and the effective mass m ∗ of the electrons are not markedly different from the room temperature values of "pure" crystals. At photon energies near the band gap, however, optical spectra in transmission, reflectivity, and emission show clearly the existence of band-tails and screening effects. A different situation holds for a highly compensated specimen: They are in a wide temperature region highly isolating, show activated photoconductivity and special structures in the optical spectra near the band gap. Their properties can be explained by assuming a meandering bandbending due to the combined action of donors and acceptors and the assumption of spatially isolated electron and hole droplets [6].

  14. An improved segmentation method for defects inspection on steel roller surface

    NASA Astrophysics Data System (ADS)

    Xu, Jirui; Li, Xuekun; Cao, Yuzhong; Shi, Depeng; Yang, Jun; Jiang, Sheng; Rong, Yiming

    2018-05-01

    In the field of metal rolling, the quality of the steel roller's surface is significant for the final rolling products, e.g. metal sheets or foils. Besides the dimensional accuracy and surface roughness, the optical uniformity of the roller surface is also required for high quality rolling application. The typical optical defects of rollers after finish grinding include speckles, chatter marks, feed traces, and combination of all above. Unlike surface roughness, the optical defects can hardly be characterized by the topography or scanning electrical microscope measurement. Only the inspection by bared eyes of experienced engineers appears to be the effective manner for surface optical defects examination for large steel rollers. In this paper, an on-site machine vision system is designed to add on to the roller grinding machine to capture the surface image, and then an improved optical defects segmentation algorithm is developed based on the active contour model. Finally, experiments are carried out to verify the efficacy of the improved model.

  15. X-ray photonic microsystems for the manipulation of synchrotron light

    DOE PAGES

    Mukhopadhyay, D.; Walko, D. A.; Jung, I. W.; ...

    2015-05-05

    In this study, photonic microsystems played an essential role in the development of integrated photonic devices, thanks to their unique spatiotemporal control and spectral shaping capabilities. Similar capabilities to markedly control and manipulate X-ray radiation are highly desirable but practically impossible due to the massive size of the silicon single-crystal optics currently used. Here we show that micromechanical systems can be used as X-ray optics to create and preserve the spatial, temporal and spectral correlation of the X-rays. We demonstrate that, as X-ray reflective optics they can maintain the wavefront properties with nearly 100% reflectivity, and as a dynamic diffractivemore » optics they can generate nanosecond time windows with over 100-kHz repetition rates. Since X-ray photonic microsystems can be easily incorporated into lab-based and next-generation synchrotron X-ray sources, they bring unprecedented design flexibility for future dynamic and miniature X-ray optics for focusing, wavefront manipulation, multicolour dispersion, and pulse slicing.« less

  16. Different effects of astrocytes and Schwann cells on regenerating retinal axons.

    PubMed

    Campbell, Gregor; Kitching, Juliet; Anderson, Patrick N; Lieberman, A Robert

    2003-11-14

    Following a crush injury of the optic nerve in adult rats, the axons of retinal ganglion cells, stimulated to regenerate by a lens injury and growing within the optic nerve, are associated predominantly with astrocytes: they remain of small diameter (0.1-0.5 microm) and unmyelinated for > or = 2 months after the operation. In contrast, when the optic nerve is cut and a segment of a peripheral nerve is grafted to the ocular stump of the optic nerve, the regenerating retinal axons are associated predominantly with Schwann cells: they are of larger diameter than in the previous experiment and include unmyelinated axons (0.2-2.5 microm) and myelinated axons (mean diameter 2.3 microm). Thus, the grafted peripheral nerve, and presumably its Schwann cells, stimulate enlargement of the regenerating retinal axons leading to partial myelination, whereas the injured optic nerve itself, and presumably its astrocytes, does not. The result points to a marked difference of peripheral (Schwann cells) and central (astrocytes) glia in their effect on regenerating retinal axons.

  17. Non linear optical investigations of silver nanoparticles synthesised by curcumin reduction

    NASA Astrophysics Data System (ADS)

    Dhanya, N. P.

    2017-11-01

    Metal nanoparticles have considerable applications in assorted fields like medicine, biology, photonics, metallurgy etc. Optical applications of Silver nanoparticles are of significant interest among researchers nowadays. In this paper, we report a single step chemical reduction of silver nanoparticles with Curcumin both as a reducing and stabilising agent at room temperature. Structural, plasmonic and non linear optical properties of the prepared nanoparticles are explored using Scanning Electron Microscope, Transmission Electron Microscope, UV absorption spectrometry, Spectroflurometry and Z scan. UV-Vis absorption studies affirm the Surface Plasmon Resonance (SPR) absorption and spectroflurometric studies announce the emission spectrum of the prepared silvernanoparticles at 520 nm. SEM and TEM images uphold the existence of uniform sized, spherical silvernanoparticles. Nonlinear optical studies are accomplished with the open aperture z scan technique in the nanosecond regime. The nonlinearity is in virtue of saturable absorption, two-photon absorption and excited state absorption. The marked nonlinearity and optical limiting of the Curcumin reduced silvernanoparticles enhances its photonic applications.

  18. EST Readers: Some Principles for Their Design and Use.

    ERIC Educational Resources Information Center

    Moore, Christopher J.

    1983-01-01

    The editor of "Heinemann's Science and Technology Readers" responds to questions concerning the objectives and design of the series. The market for technical readers; reader format and difficulty level; illustrations, technical exercises, and the language teacher; and the intended classroom use are discussed. (MSE)

  19. Mapping the reading circuitry for skilled deaf readers: an fMRI study of semantic and phonological processing.

    PubMed

    Emmorey, Karen; Weisberg, Jill; McCullough, Stephen; Petrich, Jennifer A F

    2013-08-01

    We examined word-level reading circuits in skilled deaf readers whose primary language is American Sign Language, and hearing readers matched for reading ability (college level). During fMRI scanning, participants performed a semantic decision (concrete concept?), a phonological decision (two syllables?), and a false-font control task (string underlined?). The groups performed equally well on the semantic task, but hearing readers performed better on the phonological task. Semantic processing engaged similar left frontotemporal language circuits in deaf and hearing readers. However, phonological processing elicited increased neural activity in deaf, relative to hearing readers, in the left precentral gyrus, suggesting greater reliance on articulatory phonological codes, and in bilateral parietal cortex, suggesting increased phonological processing effort. Deaf readers also showed stronger anterior-posterior functional segregation between semantic and phonological processes in left inferior prefrontal cortex. Finally, weaker phonological decoding ability did not alter activation in the visual word form area for deaf readers. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. ANNOUNCEMENT: Greetings from the Editor and Publisher

    NASA Astrophysics Data System (ADS)

    Wäppling, Roger; Williams, Sarah

    2006-01-01

    Physica Scripta is an international physics journal published for the Royal Swedish Academy of Sciences on behalf of the Nordic Science Academies and Physical Societies. This issue marks the beginning of the partnership between the Royal Swedish Academy of Sciences and Institute of Physics Publishing (IOP). We look forward to a fruitful relationship in which Physica Scripta can profit from the international reach of IOP. Authors and readers will benefit from advance publication of articles on the web prior to receiving each month's journal issue. The peer-review system will continue to be managed by Professor Roger Wäppling who will assess each paper before assigning it to an external editor or sending it for refereeing. IOP will receive new article submissions and generate electronic documents suitable for use in the refereeing process. The editorial office in Sweden will then be responsible for these manuscripts up to the final publication decision. Accepted articles will be sent to IOP for copy-editing, typesetting, production and distribution. We aim to provide our authors, referees and readers with an enhanced service for this well-established journal. IOP will maintain and augment Physica Scripta's record in publishing a broad range of high-quality research papers and we will continue to publish Topical Issues as supplements to the regular 12 issues. The popular Comments articles will continue to be published in conjunction with regular papers under this new partnership. We hope that our subscribers will continue to enjoy reading Physica Scripta as a valuable resource for general physics research.

  1. Bone images from dual-energy subtraction chest radiography in the detection of rib fractures.

    PubMed

    Szucs-Farkas, Zsolt; Lautenschlager, Katrin; Flach, Patricia M; Ott, Daniel; Strautz, Tamara; Vock, Peter; Ruder, Thomas D

    2011-08-01

    To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures. In this retrospective study, 39 patients with 204 rib fractures and 24 subjects with no fractures were examined with a single exposure dual-energy subtraction digital radiography system. Three blinded readers first evaluated the non-subtracted posteroanterior and lateral chest radiographs alone, and 3 months later they evaluated the non-subtracted images together with the subtracted posteroanterior bone images. The locations of rib fractures were registered with confidence levels on a 3-grade scale. Image quality was rated on a 5-point scale. Marks by readers were compared with fracture localizations in CT as a standard of reference. The sensivity for fracture detection using both methods was very similar (34.3% with standard CXR and 33.5% with ES-CXR, p=0.92). At the patient level, both sensitivity (71.8%) and specificity (92.9%) with or without ES were identical. Diagnostic confidence was not significantly different (2.61 with CXR and 2.75 with ES-CXR, p=0.063). Image quality with ES was rated higher than that on standard CXR (4.08 vs. 3.74, p<0.001). Despite a better image quality, adding ES bone images to standard radiographs of the chest does not provide better sensitivity or improved diagnostic confidence in the detection of rib fractures. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  2. Crimson Tide: The Harvard Books on Astronomy

    NASA Astrophysics Data System (ADS)

    Lindner, R. P.

    2001-12-01

    The Harvard Books on Astronomy, a series of crimson clad, fully illustrated volumes, cornered, for more than a generation, the market of readers interested in astronomy. A large number of astronomers owe their first serious initiation to the literature of astronomy to these books. Their style, presentation, design, and tone marked a clear departure from the inherited traditions in the field. Each summed up a field, awarded points for merit, and staked out paths for future study. No doubt each of the more mature readers of this abstract has his or her favorite volume, and even his or her own favorite edition of a particular volume. How the volumes evolved and what happened to the series with Harlow Shapley's retirement are not only questions in the history of the book but also form a commentary on the standards of scientific writing for the educated public. For this the major evidence comes from the volumes by Shapley himself, Leo Goldberg and Lawrence Aller, and the Boks. This paper discusses the origins of the series, the purpose of the works, the varying successes of the volumes, and the impact they had on the future astronomical community. In part, this is a contribution to the impact of Harlow Shapley upon the wider field and the role of Harvard in the American astronomical community. It is also a meditation upon the ways of recruitment into the field and forming ways of looking at research problems.

  3. Anterior ischemic optic neuropathy in a patient with Churg-Strauss syndrome.

    PubMed

    Lee, Ji Eun; Lee, Seung Uk; Kim, Soo Young; Jang, Tae Won; Lee, Sang Joon

    2012-12-01

    We describe a patient with Churg-Strauss syndrome who developed unilateral anterior ischemic optic neuropathy. A 54-year-old man with a history of bronchial asthma, allergic rhinitis, and sinusitis presented with sudden decreased visual acuity in his right eye that had begun 2 weeks previously. The visual acuity of his right eye was 20 / 50. Ophthalmoscopic examination revealed a diffusely swollen right optic disc and splinter hemorrhages at its margin. Goldmann perimetry showed central scotomas in the right eye and fluorescein angiography showed remarkable hyperfluorescence of the right optic nerve head. Marked peripheral eosinphilia, extravascular eosinophils in a bronchial biopsy specimen, and an increased sedimentation rate supported the diagnosis of Churg-Strauss syndrome. Therapy with methylprednisolone corrected the laboratory abnormalities, improved clinical features, and preserved vision, except for the right central visual field defect. Early recognition of this systemic disease by ophthalmologists may help in preventing severe ocular complications.

  4. Anterior Ischemic Optic Neuropathy in a Patient with Churg-Strauss Syndrome

    PubMed Central

    Lee, Ji Eun; Lee, Seung Uk; Kim, Soo Young; Jang, Tae Won

    2012-01-01

    We describe a patient with Churg-Strauss syndrome who developed unilateral anterior ischemic optic neuropathy. A 54-year-old man with a history of bronchial asthma, allergic rhinitis, and sinusitis presented with sudden decreased visual acuity in his right eye that had begun 2 weeks previously. The visual acuity of his right eye was 20 / 50. Ophthalmoscopic examination revealed a diffusely swollen right optic disc and splinter hemorrhages at its margin. Goldmann perimetry showed central scotomas in the right eye and fluorescein angiography showed remarkable hyperfluorescence of the right optic nerve head. Marked peripheral eosinphilia, extravascular eosinophils in a bronchial biopsy specimen, and an increased sedimentation rate supported the diagnosis of Churg-Strauss syndrome. Therapy with methylprednisolone corrected the laboratory abnormalities, improved clinical features, and preserved vision, except for the right central visual field defect. Early recognition of this systemic disease by ophthalmologists may help in preventing severe ocular complications. PMID:23204805

  5. Photonic jet: key role of injection for etchings with a shaped optical fiber tip.

    PubMed

    Pierron, Robin; Zelgowski, Julien; Pfeiffer, Pierre; Fontaine, Joël; Lecler, Sylvain

    2017-07-15

    We demonstrate the key role of the laser injection into a multimode fiber to obtain a photonic jet (PJ). PJ, a high concentrated propagating beam with a full width at half-maximum smaller than the diffraction limit, is here generated with a shaped optical fiber tip using a pulsed laser source (1064 nm, 100 ns, 35 kHz). Three optical injection systems of light are compared. For similar etched marks on silicon with diameters around 1 μm, we show that the required ablation energy is minimum when the injected light beam is close to the fundamental mode diameter of the fiber. Thus, we confirm experimentally that to obtain a PJ out of an optical fiber, light injection plays a role as important as that of the tip shape and, therefore, the role of the fundamental mode in the process.

  6. Lightweight helmet-mounted eye movement measurement system

    NASA Technical Reports Server (NTRS)

    Barnes, J. A.

    1978-01-01

    The helmet-mounted eye movement measuring system, weighs 1,530 grams; the weight of the present aviators' helmet in standard form with the visor is 1,545 grams. The optical head is standard NAC Eye-Mark. This optical head was mounted on a magnesium yoke which in turn was attached to a slide cam mounted on the flight helmet. The slide cam allows one to adjust the eye-to-optics system distance quite easily and to secure it so that the system will remain in calibration. The design of the yoke and slide cam is such that the subject can, in an emergency, move the optical head forward and upward to the stowed and locked position atop the helmet. This feature was necessary for flight safety. The television camera that is used in the system is a solid state General Electric TN-2000 with a charged induced device imager used as the vidicon.

  7. Near-infrared spectroscopy of the visual cortex in unilateral optic neuritis.

    PubMed

    Miki, Atsushi; Nakajima, Takashi; Takagi, Mineo; Usui, Tomoaki; Abe, Haruki; Liu, Chia-Shang J; Liu, Grant T

    2005-02-01

    To examine the occipital-lobe activation of patients with optic neuritis using near-infrared spectroscopy. Experimental study. NIRS was performed on five patients with acute unilateral optic neuritis during monocular visual stimulation. As controls, six normal subjects were also tested in the same manner. In the patients with optic neuritis, the changes in the hemoglobin concentrations (oxyhemoglobin, deoxyhemoglobin, and total hemoglobin) in the occipital lobe were found to be markedly reduced when the clinically affected eyes were stimulated compared with the fellow eyes. The response induced by the stimulation of the affected eye was decreased, even when the patient's visual acuity improved to 20/20 in the recovery phase. There was no difference in the concentration changes between the two eyes in the control subjects. NIRS may be useful in detecting visual dysfunction objectively and noninvasively in patients with visual disturbance, especially when used at the bedside.

  8. Optical changes of dentin in the near-IR as a function of mineral content

    NASA Astrophysics Data System (ADS)

    Berg, Rhett A.; Simon, Jacob C.; Fried, Daniel; Darling, Cynthia L.

    2017-02-01

    The optical properties of human dentin can change markedly due to aging, friction from opposing teeth, and acute trauma, resulting in the formation of transparent or sclerotic dentin with increased mineral density. The objective of this study was to determine the optical attenuation coefficient of human dentin tissues with different mineral densities in the near-infrared (NIR) spectral regions from 1300-2200 nm using NIR transillumination and optical coherence tomography (OCT). N=50 dentin samples of varying opacities were obtained by sectioning whole extracted teeth into 150 μm transverse sections at the cemento-enamel junction or the apical root. Transillumination images were acquired with a NIR camera and attenuation measurements were acquired at various NIR wavelengths using a NIR sensitive photodiode. Samples were imaged with transverse microradiography (gold standard) in order to determine the mineral density of each sample.

  9. A Design of a Surgical Site Verification System.

    PubMed

    Shen, Biyu; He, Yan; Chen, Haoyang

    2017-01-01

    Patient security is a significant issue in medical research and clinical practice at present. The Surgical Verification System (Patent Number: ZL 201420079273.5) is designed to recognize and check surgical sites of patients so as to ensure operation security and decrease the risk for practitioners. Composition: (1) Operating Room Server, (2) Label Reader, (3) E-Label, (4) Surgical Site Display, (5) Ward Client, (6) Label Rader-Writer, and (7) Acousto-Optic Alarm. If the Surgical identification, the surgical site, and so on are incorrect, a flashing label control will appear when the alarm rings. You can specify a sound to play for the alarm, a picture to draw, and a message to send. It is a user-friendly system.

  10. Focus on topological physics: from condensed matter to cold atoms and optics

    NASA Astrophysics Data System (ADS)

    Zhai, Hui; Rechtsman, Mikael; Lu, Yuan-Ming; Yang, Kun

    2016-08-01

    The notions of a topological phase and topological order were first introduced in the studies of integer and fractional quantum Hall effects, and further developed in the study of topological insulators and topological superconductors in the past decade. Topological concepts are now widely used in many branches of physics, not only limited to condensed matter systems but also in ultracold atomic systems, photonic materials and trapped ions. Papers published in this focus issue are direct testaments of that, and readers will gain a global view of how topology impacts different branches of contemporary physics. We hope that these pages will inspire new ideas through communication between different fields.

  11. TRIIG - Time-lapse reproduction of images through interactive graphics. [digital processing of quality hard copy

    NASA Technical Reports Server (NTRS)

    Buckner, J. D.; Council, H. W.; Edwards, T. R.

    1974-01-01

    Description of the hardware and software implementing the system of time-lapse reproduction of images through interactive graphics (TRIIG). The system produces a quality hard copy of processed images in a fast and inexpensive manner. This capability allows for optimal development of processing software through the rapid viewing of many image frames in an interactive mode. Three critical optical devices are used to reproduce an image: an Optronics photo reader/writer, the Adage Graphics Terminal, and Polaroid Type 57 high speed film. Typical sources of digitized images are observation satellites, such as ERTS or Mariner, computer coupled electron microscopes for high-magnification studies, or computer coupled X-ray devices for medical research.

  12. [Atypical optic neuritis in systemic lupus erythematosus (SLE)].

    PubMed

    Eckstein, A; Kötter, I; Wilhelm, H

    1995-11-01

    A 67-year-old woman experienced acute unilateral visual loss accompanied by pain with eye movements. There was a marked relative afferent pupillary defect and a nerve fiber bundle defect in the upper half of the visual field. Optic discs were normal. After 4 days vision worsened to motion detection and only a temporal island was left in the visual field. The optic disc margin was blurred. Since thirty years she had been suffering from renal insufficiency. Immunoserologic examination revealed elevated ANA and DS-DNA antibody titers. An optic neuritis in systemic lupus erythematosus was diagnosed, which is called atopic, because of its association to a systemic disease and the old age of the patient. The patient was treated with 100 mg prednisolone/day, slowly tapered. Within 6 weeks visual acuity improved to 0.6 and visual field normalized except for a small nerve fiber bundle defect. Autoimmune optic neuritis often responds to treatment with corticosteroids. Early onset of treatment is important. Immunopathologic examinations are an important diagnostic tool in atopic optic neuritis. Their results may even have consequences for the treatment of the underlying disease.

  13. Systems Level Analysis of Histone H3 Post-translational Modifications (PTMs) Reveals Features of PTM Crosstalk in Chromatin Regulation*

    PubMed Central

    Schwämmle, Veit; Sidoli, Simone; Ruminowicz, Chrystian; Wu, Xudong; Lee, Chung-Fan; Helin, Kristian; Jensen, Ole N.

    2016-01-01

    Histones are abundant chromatin constituents carrying numerous post-translational modifications (PTMs). Such PTMs mediate a variety of biological functions, including recruitment of enzymatic readers, writers and erasers that modulate DNA replication, transcription and repair. Individual histone molecules contain multiple coexisting PTMs, some of which exhibit crosstalk, i.e. coordinated or mutually exclusive activities. Here, we present an integrated experimental and computational systems level molecular characterization of histone PTMs and PTM crosstalk. Using wild type and engineered mouse embryonic stem cells (mESCs) knocked out in components of the Polycomb Repressive Complex 2 (PRC2, Suz12−/−), PRC1 (Ring1A/B−/−) and (Dnmt1/3a/3b−/−) we performed comprehensive PTM analysis of histone H3 tails (50 aa) by utilizing quantitative middle-down proteome analysis by tandem mass spectrometry. We characterized combinatorial PTM features across the four mESC lines and then applied statistical data analysis to predict crosstalk between histone H3 PTMs. We detected an overrepresentation of positive crosstalk (codependent marks) between adjacent mono-methylated and acetylated marks, and negative crosstalk (mutually exclusive marks) among most of the seven characterized di- and tri-methylated lysine residues in the H3 tails. We report novel features of PTM interplay involving hitherto poorly characterized arginine methylation and lysine methylation sites, including H3R2me, H3R8me and H3K37me. Integration of the H3 data with RNAseq data by coabundance clustering analysis of histone PTMs and histone modifying enzymes revealed correlations between PTM and enzyme levels. We conclude that middle-down proteomics is a powerful tool to determine conserved or dynamic interdependencies between histone marks, which paves the way for detailed investigations of the histone code. Histone H3 PTM data is publicly available in the CrossTalkDB repository at http://crosstalkdb.bmb.sdu.dk. PMID:27302890

  14. Promoting an Addiction to Reading

    ERIC Educational Resources Information Center

    Preddy, Leslie B.

    2007-01-01

    The author has identified three kinds of readers: (1) resistive and struggling; (2) apathetic and reluctant; and (3) effective and motivated. The resistive and struggling reader is often the reader who needs help building reading competency and confidence while creating ample opportunity for practice. These readers often respond to relationships…

  15. Long-Term Performance of Readers Trained in Grading Crohn Disease Activity Using MRI.

    PubMed

    Puylaert, Carl A J; Tielbeek, Jeroen A W; Bipat, Shandra; Boellaard, Thierry N; Nio, C Yung; Stoker, Jaap

    2016-12-01

    We aim to evaluate the long-term performance of readers who had participated in previous magnetic resonance imaging (MRI) reader training in grading Crohn disease activity. Fourteen readers (8 women; 12 radiologists, 2 residents; mean age 40; range 31-59), who had participated in a previous MRI reader training, participated in a follow-up evaluation after a mean interval of 29 months (range 25-34 months). Follow-up evaluation comprised 25 MRI cases of suspected or known Crohn disease patients with direct feedback; cases were identical to the evaluation set used in the initial reader training (of which readers were unaware). Grading accuracy, overstaging, and understaging were compared between training and follow-up using a consensus score by two experienced abdominal radiologists as the reference standard. In the follow-up evaluation, overall grading accuracy was 73% (95% confidence interval [CI]: 62%-81%), which was comparable to reader training grading accuracy (72%, 95% CI: 61%-80%) (P = .66). Overstaging decreased significantly from 19% (95% CI: 12%-27%) to 13% (95% CI: 8%-21%) between training and follow-up (P = .03), whereas understaging increased significantly from 9% (95% CI: 4%-21%) to 14% (95% CI: 7%-26%) (P < .01). Readers have consistent long-term accuracy for grading Crohn disease activity after case-based reader training with direct feedback. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Low self-concept in poor readers: prevalence, heterogeneity, and risk.

    PubMed

    McArthur, Genevieve; Castles, Anne; Kohnen, Saskia; Banales, Erin

    2016-01-01

    There is evidence that poor readers are at increased risk for various types of low self-concept-particularly academic self-concept. However, this evidence ignores the heterogeneous nature of poor readers, and hence the likelihood that not all poor readers have low self-concept. The aim of this study was to better understand which types of poor readers have low self-concept. We tested 77 children with poor reading for their age for four types of self-concept, four types of reading, three types of spoken language, and two types of attention. We found that poor readers with poor attention had low academic self-concept, while poor readers with poor spoken language had low general self-concept in addition to low academic self-concept. In contrast, poor readers with typical spoken language and attention did not have low self-concept of any type. We also discovered that academic self-concept was reliably associated with reading and receptive spoken vocabulary, and that general self-concept was reliably associated with spoken vocabulary. These outcomes suggest that poor readers with multiple impairments in reading, language, and attention are at higher risk for low academic and general self-concept, and hence need to be assessed for self-concept in clinical practice. Our results also highlight the need for further investigation into the heterogeneous nature of self-concept in poor readers.

  17. Low self-concept in poor readers: prevalence, heterogeneity, and risk

    PubMed Central

    Castles, Anne; Kohnen, Saskia; Banales, Erin

    2016-01-01

    There is evidence that poor readers are at increased risk for various types of low self-concept—particularly academic self-concept. However, this evidence ignores the heterogeneous nature of poor readers, and hence the likelihood that not all poor readers have low self-concept. The aim of this study was to better understand which types of poor readers have low self-concept. We tested 77 children with poor reading for their age for four types of self-concept, four types of reading, three types of spoken language, and two types of attention. We found that poor readers with poor attention had low academic self-concept, while poor readers with poor spoken language had low general self-concept in addition to low academic self-concept. In contrast, poor readers with typical spoken language and attention did not have low self-concept of any type. We also discovered that academic self-concept was reliably associated with reading and receptive spoken vocabulary, and that general self-concept was reliably associated with spoken vocabulary. These outcomes suggest that poor readers with multiple impairments in reading, language, and attention are at higher risk for low academic and general self-concept, and hence need to be assessed for self-concept in clinical practice. Our results also highlight the need for further investigation into the heterogeneous nature of self-concept in poor readers. PMID:27867764

  18. Skilled deaf readers have an enhanced perceptual span in reading.

    PubMed

    Bélanger, Nathalie N; Slattery, Timothy J; Mayberry, Rachel I; Rayner, Keith

    2012-07-01

    Recent evidence suggests that, compared with hearing people, deaf people have enhanced visual attention to simple stimuli viewed in the parafovea and periphery. Although a large part of reading involves processing the fixated words in foveal vision, readers also utilize information in parafoveal vision to preprocess upcoming words and decide where to look next. In the study reported here, we investigated whether auditory deprivation affects low-level visual processing during reading by comparing the perceptual span of deaf signers who were skilled and less-skilled readers with the perceptual span of skilled hearing readers. Compared with hearing readers, the two groups of deaf readers had a larger perceptual span than would be expected given their reading ability. These results provide the first evidence that deaf readers' enhanced attentional allocation to the parafovea is used during complex cognitive tasks, such as reading.

  19. Parallel versus sequential processing in print and braille reading.

    PubMed

    Veispak, Anneli; Boets, Bart; Ghesquière, Pol

    2012-01-01

    In the current study we investigated word, pseudoword and story reading in Dutch speaking braille and print readers. To examine developmental patterns, these reading skills were assessed in both children and adults. The results reveal that braille readers read less accurately and fast than print readers. While item length has no impact on word reading accuracy and speed in the group of print readers, it has a significant impact on reading accuracy and speed in the group of braille readers, particularly in the younger sample. This suggests that braille readers rely more strongly on an enduring sequential reading strategy. Comparison of the different reading tasks suggests that the advantage in accuracy and speed of reading in adult as compared to young braille readers is achieved through semantic top-down processing. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Topography measurements and applications in ballistics and tool mark identifications*

    PubMed Central

    Vorburger, T V; Song, J; Petraco, N

    2016-01-01

    The application of surface topography measurement methods to the field of firearm and toolmark analysis is fairly new. The field has been boosted by the development of a number of competing optical methods, which has improved the speed and accuracy of surface topography acquisitions. We describe here some of these measurement methods as well as several analytical methods for assessing similarities and differences among pairs of surfaces. We also provide a few examples of research results to identify cartridge cases originating from the same firearm or tool marks produced by the same tool. Physical standards and issues of traceability are also discussed. PMID:27182440

  1. Displacement measurement with nanoscale resolution using a coded micro-mark and digital image correlation

    NASA Astrophysics Data System (ADS)

    Huang, Wei; Ma, Chengfu; Chen, Yuhang

    2014-12-01

    A method for simple and reliable displacement measurement with nanoscale resolution is proposed. The measurement is realized by combining a common optical microscopy imaging of a specially coded nonperiodic microstructure, namely two-dimensional zero-reference mark (2-D ZRM), and subsequent correlation analysis of the obtained image sequence. The autocorrelation peak contrast of the ZRM code is maximized with well-developed artificial intelligence algorithms, which enables robust and accurate displacement determination. To improve the resolution, subpixel image correlation analysis is employed. Finally, we experimentally demonstrate the quasi-static and dynamic displacement characterization ability of a micro 2-D ZRM.

  2. Accurate positioning based on acoustic and optical sensors

    NASA Astrophysics Data System (ADS)

    Cai, Kerong; Deng, Jiahao; Guo, Hualing

    2009-11-01

    Unattended laser target designator (ULTD) was designed to partly take the place of conventional LTDs for accurate positioning and laser marking. Analyzed the precision, accuracy and errors of acoustic sensor array, the requirements of laser generator, and the technology of image analysis and tracking, the major system modules were determined. The target's classification, velocity and position can be measured by sensors, and then coded laser beam will be emitted intelligently to mark the excellent position at the excellent time. The conclusion shows that, ULTD can not only avoid security threats, be deployed massively, and accomplish battle damage assessment (BDA), but also be fit for information-based warfare.

  3. 21 CFR 886.5800 - Ophthalmic bar reader.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar reader. 886.5800 Section 886.5800...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5800 Ophthalmic bar reader. (a) Identification. An ophthalmic bar reader is a device that consists of a magnifying lens intended for use by a...

  4. What Can Readers Read after Graded Readers?

    ERIC Educational Resources Information Center

    McQuillan, Jeff

    2016-01-01

    Nation (2014) concluded that most of the vocabulary one needs to read challenging texts in English can be acquired incidentally through voluminous reading. This study examines possible texts that second language (L2) readers can use to move from controlled-vocabulary materials such as graded readers, which go up through approximately the…

  5. Benefit of the Doubt. Reader Reflections

    ERIC Educational Resources Information Center

    Mathematics Teacher, 2016

    2016-01-01

    The editors of Mathematics Teacher appreciate the interest of readers and value the views of those who write in with comments. The editors ask that name and affiliation including email address be provided at the end of their letters. This September 2016 Reader Reflections, provides reader comments on the following articles: (1) "Innocent…

  6. Moving Readers from Struggling to Proficient

    ERIC Educational Resources Information Center

    Wolter, Deborah

    2017-01-01

    If we want to move children from struggling to read to being proficient readers, we must address the disparate ways that teachers respond to readers with varying abilities. Restorative practices, akin to restorative justice, build relationships, make connections, and foster a reader's sense of ownership and empowerment. What would happen if…

  7. Semantic and Phonological Coding in Poor and Normal Readers.

    ERIC Educational Resources Information Center

    Vellutino, Frank R.; And Others

    1995-01-01

    Using poor and normal readers, three studies evaluated semantic coding and phonological coding deficits as explanations for reading disability. It was concluded that semantic coding deficits are unlikely causes of difficulties in poor readers in early stages but accrue with prolonged reading difficulties in older readers. Phonological coding…

  8. Actual Readers versus Implied Readers: Role Conflicts in Office 97.

    ERIC Educational Resources Information Center

    Shroyer, Roberta

    2000-01-01

    Explains the controversy surrounding the Office Assistant ("Paper-Clip") in Microsoft's Office 97. Discusses why actual readers rejected the default Office Assistant's role as implied writer and rebelled against the reader role implied for them. Notes users resented its intrusive behavior, rejected its implied writer role, and refused to…

  9. Using Readers' Theatre in the Classroom.

    ERIC Educational Resources Information Center

    Annarella, Lorie A.

    Reader's Theatre can be used to combine basic literature and writing instruction with creative arts. Improvisational playmaking by students, using literature in the form of plays, prose, and poetry, forms the basis of Reader's Theatre. Use of Reader's Theatre in the classroom can: (1) foster deeper understanding of character, setting, and plot…

  10. An optical microplate biosensor for the detection of methyl parathion pesticide using a biohybrid of Sphingomonas sp. cells-silica nanoparticles.

    PubMed

    Mishra, Archana; Kumar, Jitendra; Melo, Jose Savio

    2017-01-15

    The previously developed Sphingomonas sp. based optical microplate biosensor for methyl parathion (MP) was good as it detected multiple samples but had poor stability and low sensitivity. The present study aims to overcome these limitations. Silica nanoparticles (Si NP) were thus functionalized with polyethyleneimine (PEI) and the functionalized silica nanoparticles ( f Si NP) were then integrated with Sphingomonas sp. cells. The process was optimized for hydrolysis of MP into p-nitrophenol (PNP). Integration of f Si NP with cells was confirmed by FT-IR analysis. Biohybrid of Sphingomonas sp.- f Si NP was immobilized on the wells of microplate and associated directly with the optical transducer of microplate reader. Immobilized biohybrid of Sphingomonas sp.- f Si NP was characterized using SEM. A detection range of 0.1-1ppm MP was achieved from the linear range of calibration plot. After integration with f Si NP the storage stability of biohybrid was enhanced ten times from 18 to 180 days. This study proves that after interaction of cells with f Si NP, improved the sensitivity and stability of the biosensor. Spiked samples were also analyzed and correlated using this biohybrid based biosensor. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Multilayer Markov Random Field models for change detection in optical remote sensing images

    NASA Astrophysics Data System (ADS)

    Benedek, Csaba; Shadaydeh, Maha; Kato, Zoltan; Szirányi, Tamás; Zerubia, Josiane

    2015-09-01

    In this paper, we give a comparative study on three Multilayer Markov Random Field (MRF) based solutions proposed for change detection in optical remote sensing images, called Multicue MRF, Conditional Mixed Markov model, and Fusion MRF. Our purposes are twofold. On one hand, we highlight the significance of the focused model family and we set them against various state-of-the-art approaches through a thematic analysis and quantitative tests. We discuss the advantages and drawbacks of class comparison vs. direct approaches, usage of training data, various targeted application fields and different ways of Ground Truth generation, meantime informing the Reader in which roles the Multilayer MRFs can be efficiently applied. On the other hand we also emphasize the differences between the three focused models at various levels, considering the model structures, feature extraction, layer interpretation, change concept definition, parameter tuning and performance. We provide qualitative and quantitative comparison results using principally a publicly available change detection database which contains aerial image pairs and Ground Truth change masks. We conclude that the discussed models are competitive against alternative state-of-the-art solutions, if one uses them as pre-processing filters in multitemporal optical image analysis. In addition, they cover together a large range of applications, considering the different usage options of the three approaches.

  12. Three-dimensional imaging of artificial fingerprint by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Larin, Kirill V.; Cheng, Yezeng

    2008-03-01

    Fingerprint recognition is one of the popular used methods of biometrics. However, due to the surface topography limitation, fingerprint recognition scanners are easily been spoofed, e.g. using artificial fingerprint dummies. Thus, biometric fingerprint identification devices need to be more accurate and secure to deal with different fraudulent methods including dummy fingerprints. Previously, we demonstrated that Optical Coherence Tomography (OCT) images revealed the presence of the artificial fingerprints (made from different household materials, such as cement and liquid silicone rubber) at all times, while the artificial fingerprints easily spoofed the commercial fingerprint reader. Also we demonstrated that an analysis of the autocorrelation of the OCT images could be used in automatic recognition systems. Here, we exploited the three-dimensional (3D) imaging of the artificial fingerprint by OCT to generate vivid 3D image for both the artificial fingerprint layer and the real fingerprint layer beneath. With the reconstructed 3D image, it could not only point out whether there exists an artificial material, which is intended to spoof the scanner, above the real finger, but also could provide the hacker's fingerprint. The results of these studies suggested that Optical Coherence Tomography could be a powerful real-time noninvasive method for accurate identification of artificial fingerprints real fingerprints as well.

  13. Livermore time-sharing system. Part I. Octopus. Chapter 5. Card reader/card punch. [Description of card reader and formats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawrence, J.D.

    1970-03-12

    The Control Data 405 card reader, modified by the Control Data 3649 card read controller, is the primary mechanism for transferring information from a deck of punched cards into the CDC 6600 and CDC 7600 computers of the LLL Octopus system. The card reader operates at a maximum rate of 1200 cards per minute. A description of the card reader and its operation is given. A discussion of formates is included. (RWR)

  14. FormScanner: Open-Source Solution for Grading Multiple-Choice Exams

    ERIC Educational Resources Information Center

    Young, Chadwick; Lo, Glenn; Young, Kaisa; Borsetta, Alberto

    2016-01-01

    The multiple-choice exam remains a staple for many introductory physics courses. In the past, people have graded these by hand or even flaming needles. Today, one usually grades the exams with a form scanner that utilizes optical mark recognition (OMR). Several companies provide these scanners and particular forms, such as the eponymous…

  15. Building a Case for Conducting Technology Surveys On-Line.

    ERIC Educational Resources Information Center

    Denton, Jon J.; Strader, Arlen

    A Technology in Texas Public Schools 1998 Survey instrument was integrated into a Web-based response system enabling the instrument to be accessed, completed, submitted, and instantaneously analyzed over the Internet. A mark-sense or optical scan paper version of the instrument was also developed for mail-out distribution to each school district…

  16. Radio stars - A possible link between the Hipparcos optical reference frame and an extra-galactic very long baseline interferometry reference frame

    NASA Technical Reports Server (NTRS)

    Lestrade, J.-F.; Preston, R. A.; Slade, M. A.

    1983-01-01

    The concept of typing the Hipparcos optical and the JPL VLBI frames of reference by means of VLBI measurements of the positions and proper motions of the radio components of some bright stars is considered. The properties of the thermal and non-thermal radio-stars are discussed and 22 candidate stars are selected to achieve this tie. A description is given of the first VLBI attempt to detect these stars on the intercontinental baselines of the Deep Space Network with the Mark II recording system.

  17. Electron Beam/Optical Hybrid Lithography For The Production Of Gallium Arsenide Monolithic Microwave Integrated Circuits (Mimics)

    NASA Astrophysics Data System (ADS)

    Nagarajan, Rao M.; Rask, Steven D.

    1988-06-01

    A hybrid lithography technique is described in which selected levels are fabricated by high resolution direct write electron beam lithography and all other levels are fabricated optically. This technique permits subhalf micron geometries and the site-by-site alignment for each field written by electron beam lithography while still maintaining the high throughput possible with optical lithography. The goal is to improve throughput and reduce overall cost of fabricating MIMIC GaAS chips without compromising device performance. The lithography equipment used for these experiments is the Cambridge Electron beam vector scan system EBMF 6.4 capable of achieving ultra high current densities with a beam of circular cross section and a gaussian intensity profile operated at 20 kev. The optical aligner is a Karl Suss Contact aligner. The flexibility of the Cambridge electron beam system is matched to the less flexible Karl Suss contact aligner. The lithography related factors, such as image placement, exposure and process related analyses, which influence overlay, pattern quality and performance, are discussed. A process chip containing 3.2768mm fields in an eleven by eleven array was used for alignment evaluation on a 3" semi-insulating GaAS wafer. Each test chip contained five optical verniers and four Prometrix registration marks per field along with metal bumps for alignment marks. The process parameters for these chips are identical to those of HEMT/epi-MESFET ohmic contact and gate layer processes. These layers were used to evaluate the overlay accuracy because of their critical alignment and dimensional control requirements. Two cases were examined: (1) Electron beam written gate layers aligned to optically imaged ohmic contact layers and (2) Electron beam written gate layers aligned to electron beam written ohmic contact layers. The effect of substrate charging by the electron beam is also investigated. The resulting peak overlay error accuracies are: (1) Electron beam to optical with t 0.2μm (2 sigma) and (2) Electron beam to electron beam with f 0.lμm (2 sigma). These results suggest that the electron beam/optical hybrid lithography techniques could be used for MIMIC volume production as alignment tolerances required by GaAS chips are met in both cases. These results are discussed in detail.

  18. A Sign Language Screen Reader for Deaf

    NASA Astrophysics Data System (ADS)

    El Ghoul, Oussama; Jemni, Mohamed

    Screen reader technology has appeared first to allow blind and people with reading difficulties to use computer and to access to the digital information. Until now, this technology is exploited mainly to help blind community. During our work with deaf people, we noticed that a screen reader can facilitate the manipulation of computers and the reading of textual information. In this paper, we propose a novel screen reader dedicated to deaf. The output of the reader is a visual translation of the text to sign language. The screen reader is composed by two essential modules: the first one is designed to capture the activities of users (mouse and keyboard events). For this purpose, we adopted Microsoft MSAA application programming interfaces. The second module, which is in classical screen readers a text to speech engine (TTS), is replaced by a novel text to sign (TTSign) engine. This module converts text into sign language animation based on avatar technology.

  19. What are the early indicators of persistent word reading difficulties among Chinese readers in elementary grades?

    PubMed

    Yeung, Pui-Sze; Ho, Connie Suk-Han; Chan, David Wai-Ock; Chung, Kevin Kien-Hoa

    2014-05-01

    To identify the indicators of persistent reading difficulties among Chinese readers in early elementary grades, the performance of three groups of Chinese children with different reading trajectories ('persistent poor word readers', 'improved poor word readers' and 'skilled word readers') in reading-related measures was analysed in a 3-year longitudinal study. The three groups were classified according to their performance in a standardized Chinese word reading test in Grade 1 and Grade 4. Results of analysis of variance and logistic regression on the reading-related measures revealed that rapid naming and syntactic skills were important indicators of early word reading difficulty. Syntactic skills and morphological awareness were possible markers of persistent reading problems. Chinese persistent poor readers did not differ significantly from skilled readers on the measures of phonological skills. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Type Testing of Model 7200 Automatic TLD Reader.

    PubMed

    Malek Mohammadi, M; Hosseini Pooya, S M

    2017-04-20

    The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminescent dosimetry (TLD) reader. The stability of the reader, the effects of light exposure, temperature and fluctuations of primary power supply on TLD read-outs as the main parameters were investigated in this program. Moreover, this study assesses some important criteria of dosimetry system including the non-linearity of response, reusability, after effect and overload that may include significant contribution in the performance of a reader. The results showed that the TLD reader met all requirements of the IEC for the reader tests by a large margin. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Top