Killing rate of colony count by hydrodynamic cavitation due to square multi-orifice plates
NASA Astrophysics Data System (ADS)
Dong, Zhiyong; Zhao, Wenqian
2018-02-01
Currently,in water supply engineering, the conventional technique of disinfection by chlorination is employed to kill pathogenic microorganisms in raw water. However, chlorine reacts with organic compounds in water and generates disinfection byproducts (DBPs), such as trihalomethanes (THMs), haloacetic acids (HAAs) etc. These byproducts are of carcinogenic, teratogenic and mutagenic effects, which seriously threaten human health. Hydrodynamic cavitation is a novel technique of drinking water disinfection without DBPs. Effects of orifice size, orifice number and orifice layout of multi-orifice plate, cavitation number, cavitation time and orifice velocity on killing pathogenic microorganisms by cavitation were investigated experimentally in a self-developed square multi-orifice plate-type hydrodynamic cavitation device. The experimental results showed that cavitation effects increased with decrease in orifice size and increase in orifice number, cavitation time and orifice velocity. Along with lowering in cavitation number, there was an increase in Reynolds shear stress,thus enhancing the killing rate of pathogenic microorganism in raw water. In addition, the killing rate by staggered orifice layout was greater than that by checkerboard-type orifice layout.
Effect of distributor on performance of a continuous fluidized bed dryer
NASA Astrophysics Data System (ADS)
Yogendrasasidhar, D.; Srinivas, G.; Pydi Setty, Y.
2018-03-01
Proper gas distribution is very important in fluidized bed drying in industrial practice. Improper distribution of gas may lead to non-idealities like channeling, short circuiting and accumulation which gives rise to non-uniform quality of dried product. Gas distribution depends on the distributor plate used. Gas distribution mainly depends on orifice diameter, number of orifices and opening area of the distributor plate. Small orifice diameter leads to clogging, and a large orifice diameter gives uneven distribution of gas. The present work involves experimental studies using different distributor plates and simulation studies using ASPEN PLUS steady state simulator. The effect of various parameters such as orifice diameter, number of orifices and the opening area of the distributor plate on the performance of fluidized bed dryer have been studied through simulation and experimentation. Simulations were carried out (i) with increasing air inlet temperature to study the characteristics of solid temperature and moisture in outlet (ii) with increasing orifice diameter and (iii) with increase in number orifices to study the solid outlet temperature profiles. It can be observed from the simulation that, an increase in orifice diameter and number orifices increases solid outlet temperature upto certain condition and then after there is no effect with further increase. Experiments were carried out with increasing opening area (3.4 to 42%) in the form of increasing orifice diameter keeping the number of orifices constant and increasing number of orifices of the distributor plate keeping the orifice diameter constant. It can be seen that the drying rate and solid outlet temperature increase upto certain condition and then after with further increase in the orifice diameter and number of orifices, the change in the drying rate and solid outlet temperature observed is little. The optimum values of orifice diameter and number of orifices from experimentation are found to be 5 mm and 60 (22% opening area).
Reduction of Orifice-Induced Pressure Errors
NASA Technical Reports Server (NTRS)
Plentovich, Elizabeth B.; Gloss, Blair B.; Eves, John W.; Stack, John P.
1987-01-01
Use of porous-plug orifice reduces or eliminates errors, induced by orifice itself, in measuring static pressure on airfoil surface in wind-tunnel experiments. Piece of sintered metal press-fitted into static-pressure orifice so it matches surface contour of model. Porous material reduces orifice-induced pressure error associated with conventional orifice of same or smaller diameter. Also reduces or eliminates additional errors in pressure measurement caused by orifice imperfections. Provides more accurate measurements in regions with very thin boundary layers.
Hollow cathodes for arcjet thrusters
NASA Technical Reports Server (NTRS)
Luebben, Craig R.; Wilbur, Paul J.
1987-01-01
In an attempt to prevent exterior spot emission, hollow cathode bodies and orifice plates were constructed from boron nitride which is an electrical insulator, but the orifice plates melted and/or eroded at high interelectrode pressures. The most suitable hollow cathodes tested included a refractory metal orifice plate in a boron nitride body, with the insert insulated electrically from the orifice plate. In addition, the hollow cathode interior was evacuated to assure a low pressure at the insert surface, thus promoting diffuse electron emission. At high interelectrode pressures, the electrons tended to flow through the orifice plate rather than through the orifice, which could result in overheating of the orifice plate. Using a carefully aligned centerline anode, electron flow through the orifice could be sustained at interelectrode pressures up to 500 torr - but the current flow path still occasionally jumped from the orifice to the orifice plate. Based on these tests, it appears that a hollow cathode would operate most effectively at pressures in the arcjet regime with a refractory, chemically stable, and electrically insulating cathode body and orifice plate.
NASA Technical Reports Server (NTRS)
Montoya, L. C.; Lux, D. P.
1975-01-01
Wing pressure distributions obtained in flight with flush orifice and external tubing orifice installations for Mach numbers from 0.50 to 0.97 are compared. The procedure used to install the external tubing orifice is discussed. The results indicate that external tubing orifice installations can give useful results.
Orifice plate for controlling solids flow, methods of use thereof and articles comprising the same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jukkola, Glen D.; Teigen, Bard C.
Disclosed herein is an orifice plate comprising one or more plates having orifices disposed therein; the orifices being operative to permit the flow of solids from a moving bed heat exchanger to a solids flow control system; where the orifice plate is downstream of a tube bundle of the moving bed heat exchanger and upstream of the solids flow control system and wherein the orifice plate is operative to evenly distribute the flow of solids in the solids flow control system.
Effects of Reynolds number on orifice induced pressure error
NASA Technical Reports Server (NTRS)
Plentovich, E. B.; Gloss, B. B.
1982-01-01
Data previously reported for orifice induced pressure errors are extended to the case of higher Reynolds number flows, and a remedy is presented in the form of a porous metal plug for the orifice. Test orifices with apertures 0.330, 0.660, and 1.321 cm in diam. were fabricated on a flat plate for trials in the NASA Langley wind tunnel at Mach numbers 0.40-0.72. A boundary layer survey rake was also mounted on the flat plate to allow measurement of the total boundary layer pressures at the orifices. At the high Reynolds number flows studied, the orifice induced pressure error was found to be a function of the ratio of the orifice diameter to the boundary layer thickness. The error was effectively eliminated by the insertion of a porous metal disc set flush with the orifice outside surface.
Experimental investigation of hydrodynamic cavitation through orifices of different geometries
NASA Astrophysics Data System (ADS)
Rudolf, Pavel; Kubina, Dávid; Hudec, Martin; Kozák, Jiří; Maršálek, Blahoslav; Maršálková, Eliška; Pochylý, František
Hydrodynamic cavitation in single and multihole orifices was experimentally investigated to assess their hydraulic characteristics: loss coefficients, inception cavitation number, cavitation number for transition to supercavitation. Significant difference for singlehole and multihole orifices was observed in terms of the measured loss coefficient. It is significantly more effective to use multihole orifices, where energy dissipation is much lower.It was found that using scaling factor given by ratio of orifice thickness suggests linear behaviour of both loss coefficient and inception cavitation number. Orifices seem to be convenient choice as flow constriction devices inducing cavitation due to their simplicity.
High Pressure Water Stripping Using Multi-Orifice Nozzles
NASA Technical Reports Server (NTRS)
Hoppe, David
1999-01-01
The use of multi-orifice rotary nozzles greatly increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with its transverse velocity as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Orifices at the outer edge of the nozzle head move at a faster rate than the orifices located near the center. The energy transmitted to the surface from the impact force of the water stream from an outer orifice is therefore spread over a larger area than energy from an inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the total energy transmitted from the outer orifice to compensate for the wider distribution of energy. The total flow rate from the combination of all orifices must be monitored and should be kept below the pump capacity while choosing orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all the orifices in the nozzle head pass through the center section. All orifices contribute to the stripping in the center of the path while only the outer most orifice contributes to the stripping at the edge of the nozzle. Additional orifices contribute to the stripping from the outer edge toward the center section. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation graphically indicates the cumulative affect from each parameter selected. The result from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas while leaving the coating untouched in adjacent sections. The high pressure water stripping system can be set to extremely aggressive conditions allowing stripping of hard to remove adhesives, paint systems, and even cladding and chromate conversion coatings. The energy force can also be reduced to strip coatings from thin aluminum substrates without causing any damage or deterioration to the substrate's surface. High pressure water stripping of aerospace components has thus proven to be an efficient and cost effective method for cleaning and removing coatings.
Study of orifice fabrication technologies for the liquid droplet radiator
NASA Technical Reports Server (NTRS)
Wallace, David B.; Hayes, Donald J.; Bush, J. Michael
1991-01-01
Eleven orifice fabrication technologies potentially applicable for a liquid droplet radiator are discussed. The evaluation is focused on technologies capable of yielding 25-150 microns diameter orifices with trajectory accuracies below 5 milliradians, ultimately in arrays of up to 4000 orifices. An initial analytical screening considering factors such as trajectory accuracy, manufacturability, and hydrodynamics of orifice flow is presented. Based on this screening, four technologies were selected for experimental evaluation. A jet straightness system used to test 50-orifice arrays made by electro-discharge machining (EDM), Fotoceram, and mechanical drilling is discussed. Measurements on orifice diameter control and jet trajectory accuracy are presented and discussed. Trajectory standard deviations are in the 4.6-10.0 milliradian range. Electroforming and EDM appear to have the greatest potential for Liquid Droplet Radiator applications. The direction of a future development effort is discussed.
Gas Generator Feedline Orifice Sizing Methodology: Effects of Unsteadiness and Non-Axisymmetric Flow
NASA Technical Reports Server (NTRS)
Rothermel, Jeffry; West, Jeffrey S.
2011-01-01
Engine LH2 and LO2 gas generator feed assemblies were modeled with computational fluid dynamics (CFD) methods at 100% rated power level, using on-center square- and round-edge orifices. The purpose of the orifices is to regulate the flow of fuel and oxidizer to the gas generator, enabling optimal power supply to the turbine and pump assemblies. The unsteady Reynolds-Averaged Navier-Stokes equations were solved on unstructured grids at second-order spatial and temporal accuracy. The LO2 model was validated against published experimental data and semi-empirical relationships for thin-plate orifices over a range of Reynolds numbers. Predictions for the LO2 square- and round-edge orifices precisely match experiment and semi-empirical formulas, despite complex feedline geometry whereby a portion of the flow from the engine main feedlines travels at a right-angle through a smaller-diameter pipe containing the orifice. Predictions for LH2 square- and round-edge orifice designs match experiment and semi-empirical formulas to varying degrees depending on the semi-empirical formula being evaluated. LO2 mass flow rate through the square-edge orifice is predicted to be 25 percent less than the flow rate budgeted in the original engine balance, which was subsequently modified. LH2 mass flow rate through the square-edge orifice is predicted to be 5 percent greater than the flow rate budgeted in the engine balance. Since CFD predictions for LO2 and LH2 square-edge orifice pressure loss coefficients, K, both agree with published data, the equation for K has been used to define a procedure for orifice sizing.
Optimization of Orifice Geometry for Cross-Flow Mixing in a Cylindrical Duct
NASA Technical Reports Server (NTRS)
Sowa, W. A.; Kroll, J. T.; Samuelsen, G. S.; Holdeman, J. D.
1994-01-01
Mixing of gaseous jets in a cross-flow has significant applications in engineering, one example of which is the dilution zone of a gas turbine combustor. Despite years of study, the design of jet injection in combustors is largely based on practical experience. A series of experiments was undertaken to delineate the optimal mixer orifice geometry. A cross-flow to core-flow momentum-flux ratio of 40 and a mass flow ratio of 2.5 were selected as representative of an advanced design. An experimental test matrix was designed around three variables: the number of orifices, the orifice aspect ratio (long-to-short dimension), and the orifice angle. A regression analysis was performed on the data to arrive at an interpolating equation that predicted the mixing performance of orifice geometry combinations within the range of the test matrix parameters. Results indicate that mixture uniformity is a non-linear function of the number of orifices, the orifice aspect ratio, and the orifice angle. Optimum mixing occurs when the asymptotic mean jet trajectories are in the range of 0.35 less than r/R less than 0.5 (where r = 0 is at the mixer wall) at z/R = 1.0. At the optimum number of orifices, the difference between shallow-angled slots with large aspect ratios and round holes is minimal and either approach will lead to good mixing performance. At the optimum number of orifices, it appears possible to have two local optimums where one corresponds to an aspect ratio of 1.0 and the other to a high aspect ratio.
Drilling Precise Orifices and Slots
NASA Technical Reports Server (NTRS)
Richards, C. W.; Seidler, J. E.
1983-01-01
Reaction control thrustor injector requires precisely machined orifices and slots. Tooling setup consists of rotary table, numerical control system and torque sensitive drill press. Components used to drill oxidizer orifices. Electric discharge machine drills fuel-feed orifices. Device automates production of identical parts so several are completed in less time than previously.
Subsonic tests of an all-flush-pressure-orifice air data system
NASA Technical Reports Server (NTRS)
Larson, T. J.; Siemers, P. M., III
1981-01-01
The use of an all-flush-pressure-orifice array as a subsonic air data system was evaluated in flight and wind tunnel tests. Two orifice configurations were investigated. Both used orifices arranged in a cruciform pattern on the airplane nose. One configuration also used orifices on the sides of the fuselage for a source of static pressure. The all-nose-orifice configuration was similar to the shuttle entry air data system (SEADS). The flight data were obtained with a KC-135A airplane. The wind tunnel data were acquired with a 0.035-scale model of the KC-135A airplane. With proper calibration, several orifices on the vertical centerline of the vehicle's nose were found to be satisfactory for the determination of total pressure and angle of attack. Angle of sideslip could be accurately determined from pressure measurements made on the horizontal centerline of the aircraft. Orifice pairs were also found that provided pressure ratio relationships suitable for the determination of Mach number. The accuracy that can be expected for the air data determined with SEADS during subsonic orbiter flight is indicated.
Effect of mitral orifice shape on intra-ventricular filling fluid dynamics
NASA Astrophysics Data System (ADS)
Okafor, Ikechukwu; Angirish, Yagna; Yoganathan, Ajit; Santhanakrishnan, Arvind
2013-11-01
The natural geometry of the mitral orifice is D-shaped. However, most current designs of prosthetic valves employ O-shaped orifice geometry. The goal of this study was to compare the effect of geometrical modification between the D and O orifice on the intra-ventricular fluid dynamics during diastolic filling. The different mitral orifice geometries were incorporated into an in vitro left heart simulator consisting of a flexible-walled anatomical left ventricle (LV) physical model enclosed in an acrylic housing. Physiological flow rates and pressures were obtained via tuning systemic resistance and compliance elements in the flow loop. A programmable piston pump was used to generate the LV model wall motion. 2D Particle image velocimetry measurements were conducted along multiple longitudinal planes perpendicular to the annulus plane. During peak diastole, the incoming jet width at the LV central plane was smaller for the D-orifice than that of the O-orifice. Further, the core of the vortex ring in the D-orifice was reduced in size compared to that of the O-orifice. The spatiotemporal spreading of the inflow jet as well as the propagation of the vortex ring will be discussed. This study was funded by a grant from the National Heart, Lung and Blood Institute (RO1HL70262).
Effect of slotted exit orifice on performance of plasma synthetic jet actuator
NASA Astrophysics Data System (ADS)
Zong, Haohua; Kotsonis, Marios
2017-03-01
This study experimentally investigates the influence of exit orifice shape on the performance characteristics of a three-electrode plasma synthetic jet actuator. High-speed Schlieren imaging system and phase-locked two-component PIV measurements are used for flowfield characterisation in quiescent conditions. Two actuator configurations with the same exit area but different exit orifice shape (round orifice and slot orifice) are studied. Results indicate a close correspondence between the shapes of the starting vortex ring with the shapes of the respective exit orifices. For the slot orifice, the elongated starting vortex ring gradually expands during propagation, while its ends become warped. A distinct K-H instability structure is observed, inducing continuous oscillation of the high-speed jet. Compared with the jet from the round orifice, the slot jet has a higher entrainment rate of surrounding air, thus resulting in a lower propagation velocity of the jet front. The exit velocity of PSJA within one period initially shows a rapid increase, then persists at a relatively high level (100-130 m/s), and finally drops with some small-scale oscillations. The oscillation amplitude is less than 10 m/s, and the oscillation period is approximately 600 µs. Under conditions of same exit area, orifice shape has little influence on the variation of the exit velocity.
Parametric measurements of the effect of in-duct orifice edge shape on its noise damping performance
NASA Astrophysics Data System (ADS)
Ji, Chenzhen; Zhao, Dan; Han, Nuomin; Li, Jing
2016-12-01
Acoustic liners perforated with thousands of millimeter-size orifices are widely used in aero-engines and gas turbine engines as an effective noise damper. In this work, experimental investigations of the acoustic damping effect of in-duct perforated orifices are performed on a cold-flow pipe. A mean flow (also known as bias flow) is applied and its flow rate is variable. Emphasis is placed on the effect of the orifice edge shape. For this, 16 in-duct orifices with different edge shapes and porosities are designed and manufactured by using 3D printing technology and conventional laser cutting technique. The damping effect of these in-duct orifices is characterized by using power absorption coefficient Δ and reflection coefficient χ from 100 to 1000 Hz. The performances of these orifices are found to be either improved or deteriorated, depending on (1) edge shape, (2) the ratio T/d of orifice thickness to its diameter, (3) the bias flow Mach number, (4) downstream pipe length Ld and (5) porosity η via varying either the number N or surface area Ao of the orifices. In addition, modifying orifice edge does not lead to an increase of power absorption at lower frequency (⩽ 700 Hz). However, as the frequency is increased, the orifice with square (S-type) edge is found to be associated with 10 percent more power absorption. It is interesting to find that T/d over the tested range (≤ 0.5) has little influence on its damping capacity. However, the mean bias flow Mach number Ma and porosity η are shown to play critical roles on determining the noise damping performance of these orifices. Maximum power absorption Δmax is found to occur at Ma ≈ 0.018, while the optimum porosity corresponding to Δmax is approximately 7 percent. The present parametric measurements shed light on the roles of orifice edge shape, porosity and mean flow on its noise damping capacity, and facilitate the design of effective perforated liners.
Porous plug for reducing orifice induced pressure error in airfoils
NASA Technical Reports Server (NTRS)
Plentovich, Elizabeth B. (Inventor); Gloss, Blair B. (Inventor); Eves, John W. (Inventor); Stack, John P. (Inventor)
1988-01-01
A porous plug is provided for the reduction or elimination of positive error caused by the orifice during static pressure measurements of airfoils. The porous plug is press fitted into the orifice, thereby preventing the error caused either by fluid flow turning into the exposed orifice or by the fluid flow stagnating at the downstream edge of the orifice. In addition, the porous plug is made flush with the outer surface of the airfoil, by filing and polishing, to provide a smooth surface which alleviates the error caused by imperfections in the orifice. The porous plug is preferably made of sintered metal, which allows air to pass through the pores, so that the static pressure measurements can be made by remote transducers.
Experimental and numerical modeling of rarefied gas flows through orifices and short tubes
NASA Astrophysics Data System (ADS)
Gimelshein, S. F.; Markelov, G. N.; Lilly, T. C.; Selden, N. P.; Ketsdever, A. D.
2005-05-01
Flow through circular orifices with thickness-to-diameter ratios varying from 0.015 to 1.2 is studied experimentally and numerically with kinetic and continuum approaches. Helium and nitrogen gases are used in the range of Reynolds numbers from 0.02 to over 700. Good agreement between experimental and numerical results is observed for mass flow and thrust corrected for the experimental facility background pressure. For thick-to-thin orifice ratios of mass flow and thrust vs pressure, a minimum is established. The thick orifice propulsion efficiency is much higher than that of a thin orifice. The effects of edge roundness and surface specularity on a thick orifice specific impulse were found to be relatively small.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hiromu Isaka; Masatsugu Tsutsumi; Tadashi Shiraishi
2002-07-01
The authors performed experimental study for the purpose of the following two items from a viewpoint of cavitation erosion of a cylindrical orifice in view of a problem at the letdown orifice in PWR (Pressurized Water Reactor). 1. To get the critical cavitation parameter of the cylindrical orifice to establish the design criteria for prevention of cavitation erosion, and 2. to ascertain the erosion rate in such an eventuality that the cavitation erosion occurs with the orifice made of stainless steel with precipitation hardening (17-4-Cu hardening type stainless steel), so that we confirm the appropriateness of the design criteria. Regardingmore » the 1. item, we carried out the cavitation tests to get the critical cavitation parameters inside and downstream of the orifice. The test results showed that the cavitation parameter at inception is independent of the length or the diameter of the orifice. Moreover, the design criteria of cavitation erosion of cylindrical orifices have been established. Regarding the 2. item, we tested the erosion rate under high-pressure conditions. The cavitation erosion actually occurred in the cylindrical orifice at the tests that was strongly resemble to the erosion occurred at the plant. It will be seldom to reproduce resemble cavitation erosion in a cylindrical orifice with the hard material used at plants. We could establish the criteria for preventing the cavitation erosion from the test results. (authors)« less
2007-06-01
varies as the cavitation number is lowered. The third is supercavitation where the vapor pocket attachment has moved to the orifice exit and beyond but...the flow still acts as attached. For this study only the 90 degree orifice angle configuration experienced supercavitation . For all other angles
NASA Technical Reports Server (NTRS)
Hersch, A. S.; Walker, B.
1979-01-01
A semiempirical fluid mechanical model is derived for the acoustic behavior of thin-walled single orifice Helmholtz resonators in a grazing flow environment. The incident and cavity sound fields are connected in terms of an orifice discharge coefficient whose values are determined experimentally using the two-microphone method. Measurements show that at high grazing flow speeds, acoustical resistance is almost linearly proportional to the grazing flow speed and almost independent of incident sound pressure. The corresponding values of reactance are much smaller and tend towards zero. For thicker-walled orifice plates, resistance and reactance were observed to be less sensitive to grazing flow as the ratio of plate thickness to orifice diameter increased. Loud tones were observed to radiate from a single orifice Helmholtz resonator due to interaction between the grazing flow shear layer and the resonator cavity. Measurements showed that the tones radiated at a Strouhal number equal to 0.26. The effects of grazing flow on the impedance of Helmholtz resonators consisting of clusters of orifices was also studied. In general, both resistance and reaction were found to be virtually independent of orifice relative spacing and number. These findings are valid with and without grazing flow.
Numerical analysis of eccentric orifice plate using ANSYS Fluent software
NASA Astrophysics Data System (ADS)
Zahariea, D.
2016-11-01
In this paper the eccentric orifice plate is qualitative analysed as compared with the classical concentric orifice plate from the point of view of sedimentation tendency of solid particles in the fluid whose flow rate is measured. For this purpose, the numerical streamlines pattern will be compared for both orifice plates. The numerical analysis has been performed using ANSYS Fluent software. The methodology of CFD analysis is presented: creating the 3D solid model, fluid domain extraction, meshing, boundary condition, turbulence model, solving algorithm, convergence criterion, results and validation. Analysing the numerical streamlines, for the concentric orifice plate can be clearly observed two circumferential regions of separated flows, upstream and downstream of the orifice plate. The bottom part of these regions are the place where the solid particles could sediment. On the other hand, for the eccentric orifice plate, the streamlines pattern suggest that no sedimentation will occur because at the bottom area of the pipe there are no separated flows.
Flow visualization in long neck Helmholtz resonators with grazing flow
NASA Technical Reports Server (NTRS)
Baumeister, K. J.; Rice, E. J.
1976-01-01
Both oscillating and steady flows were applied to a single plexiglass resonator cavity with colored dyes injected in both the orifice and grazing flow field to record the motion of the fluid. For oscillatory flow, the instantaneous dye streamlines were similar for both the short and long-neck orifices. The orifice flow blockage appears to be independent of orifice length for a fixed amplitude of flow oscillation and magnitude of the grazing flow. The steady flow dye studies showed that the acoustic and steady flow resistances do not necessarily correspond for long neck orifices.
High Pressure Water Stripping Using Multi-Orifice Nozzles
NASA Technical Reports Server (NTRS)
Hoppe, David T.
1998-01-01
The use of multi-orifice rotary nozzles not only increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with the transverse velocity of the nozzle as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Since orifices at the outer edge of the nozzle head move at a faster rate than the orifice located near the center, the energy impact force of the water stream from the outer orifice is spread over a larger area than the water streams from the inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the energy impact to compensate for its wider force distribution. The total flow rate from the combination of orifices must be monitored and kept below the pump capacity while choosing an orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all orifices in the nozzle head pass through the center section, contributing to the stripping in this area while only the outer most orifice contributes to the stripping in the shell area at the extreme outside edge of the nozzle. From t he outer most shell to the center section, more orifices contribute to the stripping in each progressively reduced diameter shell. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation responds by graphically indicating the cumulative affect from each parameter selected. The results from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas while leaving the coating untouched in adjacent sections. The high pressure water stripping system can be set to extremely aggressive conditions allowing stripping of hard to remove adhesives, paint systems, cladding and chromate conversion coatings. The energy force can be reduced to strip coatings from thin aluminum substrates without causing damage or deterioration to the substrate's surface. High pressure water stripping of aerospace components have thus proven to be an efficient and cost effective method for cleaning and removing coatings.
Shiota, T; Jones, M; Yamada, I; Heinrich, R S; Ishii, M; Sinclair, B; Holcomb, S; Yoganathan, A P; Sahn, D J
1996-02-01
The aim of the present study was to evaluate dynamic changes in aortic regurgitant (AR) orifice area with the use of calibrated electromagnetic (EM) flowmeters and to validate a color Doppler flow convergence (FC) method for evaluating effective AR orifice area and regurgitant volume. In 6 sheep, 8 to 20 weeks after surgically induced AR, 22 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary EM flowmeters balanced against each other. Instantaneous AR orifice areas were determined by dividing these actual AR flow rates by the corresponding continuous wave velocities (over 25 to 40 points during each diastole) matched for each steady state. Echo studies were performed to obtain maximal aliasing distances of the FC in a low range (0.20 to 0.32 m/s) and a high range (0.70 to 0.89 m/s) of aliasing velocities; the corresponding maximal AR flow rates were calculated using the hemispheric flow convergence assumption for the FC isovelocity surface. AR orifice areas were derived by dividing the maximal flow rates by the maximal continuous wave Doppler velocities. AR orifice sizes obtained with the use of EM flowmeters showed little change during diastole. Maximal and time-averaged AR orifice areas during diastole obtained by EM flowmeters ranged from 0.06 to 0.44 cm2 (mean, 0.24 +/- 0.11 cm2) and from 0.05 to 0.43 cm2 (mean, 0.21 +/- 0.06 cm2), respectively. Maximal AR orifice areas by FC using low aliasing velocities overestimated reference EM orifice areas; however, at high AV, FC predicted the reference areas more reliably (0.25 +/- 0.16 cm2, r = .82, difference = 0.04 +/- 0.07 cm2). The product of the maximal orifice area obtained by the FC method using high AV and the velocity time integral of the regurgitant orifice velocity showed good agreement with regurgitant volumes per beat (r = .81, difference = 0.9 +/- 7.9 mL/beat). This study, using strictly quantified AR volume, demonstrated little change in AR orifice size during diastole. When high aliasing velocities are chosen, the FC method can be useful for determining effective AR orifice size and regurgitant volume.
Effects of Orifice-Weir Outlet on Hydrology and Water Quality of a Drained Forested Watershed
Devendra M. Amatya; R. Wayne Skaggs; J.W. Gilliam; J.H. Hughes
2003-01-01
Orifice-weir structures at ditch outlets are proposed to reduce peak drainage rates during high flows and to store water during the growing season in poorly drained managed pine plantations. Two coastal watersheds, one conventionally drained (D1) and another with an orifice-weir outlet (D3), were monitored to examine the effects of this orifice treatment on drainage...
2015-04-01
9 Fig. 8 Resistance of orifice flow plotted vs. flow velocity. Acoustic ohm units are dynes∙s∙cm5; the changing resistance demonstrates the...process of nonlinear flow through the orifice. (The blue single-orifice fit and the red total resistance for a dual orifice configuration were added...piston hearing protection model with level- dependent extensions in cushion visco-elastic elements and leakage flow impedance
Field calibration of orifice meters for natural gas flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ting, V.C.; Shen, J.J.S.
1989-03-01
This paper presents the orifice calibration results for nominal 15.24, 10.16, and 5.08-cm (6,4,2-in.) orifice meters conducted at the Chevron's Sand Hills natural gas flow measurement facility in Crane, Texas. Over 200 test runs were collected in a field environment to study the accuracy of the orifice meters. Data were obtained at beta ratios ranging from 0.12 to 0.74 at the nominal conditions of 4576 kPa and 27{sup 0}C (650 psig and 80{sup 0}F) with a 0.57 specific gravity processed, pipeline quality natural gas. A bank of critical flow nozzles was used as the flow rate proving device to calibratemore » the orifice meters. Orifice discharge coefficients were computed with ANSI/API 2530-1985 (AGA3) and ISO 5167/ASME MFC-3M-1984 equations for every set of data points. With the orifice bore Reynolds numbers ranging from 1 to 9 million, the Sand Hills calibration data bridge the gap between the Ohio State water data at low Reynolds numbers and Chevron's high Reynolds number test data taken at a large test facility in Venice, Louisiana. The test results also successfully demonstrate that orifice meters can be accurately proved with critical flow nozzles under realistic field conditions.« less
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Liscinsky, D. S.; Bain, D. B.
1999-01-01
This paper summarizes experimental and computational results on the mixing of opposed rows of jets with a confined subsonic crossflow in rectangular ducts. The studies from which these results were excerpted investigated flow and geometric variations typical of the complex three-dimensional flowfield in the combustion chambers in gas turbine engines. The principal observation was that the momentum-flux ratio, J, and the orifice spacing, S/H, were the most significant flow and geometric variables. Jet penetration was critical, and penetration decreased as either momentum-flux ratio or orifice spacing decreased. It also appeared that jet penetration remained similar with variations in orifice size, shape, spacing, and momentum-flux ratio when the orifice spacing was inversely proportional to the square-root of the momentum-flux ratio. It was also seen that planar averages must be considered in context with the distributions. Note also that the mass-flow ratios and the orifices investigated were often very large (jet-to-mainstream mass-flow ratio > 1 and the ratio of orifices-area-to-mainstream- cross-sectional-area up to 0.5, respectively), and the axial planes of interest were often just downstream of the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Bock, Hendrik Pieter Jacobus; Alexander, James Pellegrino; El-Refaie, Ayman Mohamed Fawzi
2016-06-21
An apparatus, such as an electrical machine, is provided. The apparatus can include a rotor defining a rotor bore and a conduit disposed in and extending axially along the rotor bore. The conduit can have an annular conduit body defining a plurality of orifices disposed axially along the conduit and extending through the conduit body. The rotor can have an inner wall that at least partially defines the rotor bore. The orifices can extend through the conduit body along respective orifice directions, and the rotor and conduit can be configured to provide a line of sight along the orifice directionmore » from the respective orifices to the inner wall.« less
Compression ignition engine having fuel system for non-sooting combustion and method
Bazyn, Timothy; Gehrke, Christopher
2014-10-28
A direct injection compression ignition internal combustion engine includes a fuel system having a nozzle extending into a cylinder of the engine and a plurality of spray orifices formed in the nozzle. Each of the spray orifices has an inner diameter dimension of about 0.09 mm or less, and define inter-orifice angles between adjacent spray orifice center axes of about 36.degree. or greater such that spray plumes of injected fuel from each of the spray orifices combust within the cylinder according to a non-sooting lifted flame and gas entrainment combustion pattern. Related methodology is also disclosed.
Calibration and use of filter test facility orifice plates
NASA Astrophysics Data System (ADS)
Fain, D. E.; Selby, T. W.
1984-07-01
There are three official DOE filter test facilities. These test facilities are used by the DOE, and others, to test nuclear grade HEPA filters to provide Quality Assurance that the filters meet the required specifications. The filters are tested for both filter efficiency and pressure drop. In the test equipment, standard orifice plates are used to set the specified flow rates for the tests. There has existed a need to calibrate the orifice plates from the three facilities with a common calibration source to assure that the facilities have comparable tests. A project has been undertaken to calibrate these orifice plates. In addition to reporting the results of the calibrations of the orifice plates, the means for using the calibration results will be discussed. A comparison of the orifice discharge coefficients for the orifice plates used at the seven facilities will be given. The pros and cons for the use of mass flow or volume flow rates for testing will be discussed. It is recommended that volume flow rates be used as a more practical and comparable means of testing filters. The rationale for this recommendation will be discussed.
Apparatus for depositing hard coating in a nozzle orifice
Flynn, P.L.; Giammarise, A.W.
1995-02-21
The present invention is directed to a process for coating the interior surfaces of an orifice in a substrate that forms a slurry fuel injection nozzle. In a specific embodiment, the nozzle is part of a fuel injection system for metering a coal-water slurry into a large, medium-speed, multi-cylinder diesel engine. In order to retard erosion of the orifice, the substrate is placed in a chemical vapor deposition (CVD) reaction chamber. A reaction gas is passed into the chamber at a gas temperature below its reaction temperature and is directed through the orifice in the substrate. The gas reaction temperature is a temperature at and above which the reaction gas deposits as a coating, and the reaction gas is of a composition whereby improved resistance to erosion by flow of the particulates in the slurry fuel is imparted by the deposited coating. Only the portion of the substrate in proximity to the orifice to be coated is selectively heated to at least the gas reaction temperature for effecting coating of the orifice`s interior surfaces by the vapor deposited coating formed from the reaction gas. 2 figs.
NASA Technical Reports Server (NTRS)
Larson, T. J.; Siemers, P. M., III
1980-01-01
Wind tunnel pressure measurements were acquired from orifices on a 0.1 scale forebody model of the space shuttle orbiter that were arranged in a preliminary configuration of the shuttle entry air data system (SEADS). Pressures from those and auxiliary orifices were evaluated for their ability to provide air data at subsonic and transonic speeds. The orifices were on the vehicle's nose cap and on the sides of the forebody forward of the cabin. The investigation covered a Mach number range of 0.25 to 1.40 and an angle of attack range from 4 deg. to 18 deg. An air data system consisting of nose cap and forebody fuselage orifices constitutes a complete and accurate air data system at subsonic and transonic speeds. For Mach numbers less than 0.80 orifices confined to the nose cap can be used as a complete and accurate air data system. Air data systems that use only flush pressure orifices can be used to determine basic air data on other aircraft at subsonic and transonic speeds.
Active Control of Liner Impedance by Varying Perforate Orifice Geometry
NASA Technical Reports Server (NTRS)
Ahuji, K. K.; Gaeta, R. J., Jr.
2000-01-01
The present work explored the feasibility of controlling the acoustic impedance of a resonant type acoustic liner. This was accomplished by translating one perforate over another of the same porosity creating a totally new perforate that had an intermediate porosity. This type of adjustable perforate created a variable orifice perforate whose orifices were non-circular. The key objective of the present study was to quantify, the degree of attenuation control that can be achieved by applying such a concept to the buried septum in a two-degree-of-freedom (2DOF) acoustic liner. An additional objective was to examine the adequacy of the existing impedance models to explain the behavior of the unique orifice shapes that result from the proposed silding perforate concept. Different orifice shapes with equivalent area were also examined to determine if highly non-circular orifices had a significant impact on the impedance.
NASA Technical Reports Server (NTRS)
Larson, T. J.; Flechner, S. G.; Siemers, P. M., III
1980-01-01
The results of a wind tunnel investigation on an all flush orifice air data system for use on a KC-135A aircraft are presented. The investigation was performed to determine the applicability of fixed all flush orifice air data systems that use only aircraft surfaces for orifices on the nose of the model (in a configuration similar to that of the shuttle entry air data system) provided the measurements required for the determination of stagnation pressure, angle of attack, and angle of sideslip. For the measurement of static pressure, additional flush orifices in positions on the sides of the fuselage corresponding to those in a standard pitot-static system were required. An acceptable but less accurate system, consisting of orifices only on the nose of the model, is defined and discussed.
A parametric numerical study of mixing in a cylindrical duct
NASA Astrophysics Data System (ADS)
Oechsle, V. L.; Mongia, H. C.; Holderman, J. D.
1992-07-01
The interaction is described of some of the important parameters affecting the mixing process in a quick mixing region of a rich burn/quick mix/lean burn (RQL) combustor. The performance of the quick mixing region is significantly affected by the geometric designs of both the mixing domain and the jet inlet orifices. Several of the important geometric parameters and operating conditions affecting the mixing process were analytically studied. Parameters such as jet-to-mainstream momentum flux ratio (J), mass flow ratio (MR), orifice geometry, orifice orientation, and number of orifices/row (equally spaced around the circumferential direction were analyzed. Three different sets of orifice shapes were studied: (1) square, (2) elongated slots, and (3) equilateral triangles. Based on the analytical results, the best mixing configuration depends significantly on the penetration depth of the jet to prevent the hot mainstream flow from being entrained behind the orifice. The structure in a circular mixing section is highly weighted toward the outer wall and any mixing structure affecting this area significantly affects the overall results. The increase in the number of orifices per row increases the mixing at higher J conditions. Higher slot slant angles and aspect ratios are generally the best mixing configurations at higher momentum flux ratio (J) conditions. However, the square and triangular shaped orifices were more effective mixing configurations at lower J conditions.
Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility
NASA Technical Reports Server (NTRS)
Bozak, Richard F.
2018-01-01
Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.
Nath, Ranjit Kumar; Soni, Dheeraj Kumar
2016-08-01
A 24-year-old female patient presented to us with progressive dyspnea on exertion for last three year. She was not a known case of rheumatic heart disease. Her physical examination showed regular pulse and her blood pressure was 100/76 mm Hg. Cardiac palpation showed grade 3 parasternal heave and auscultation revelled an accentuated first heart sound, loud P2 and mid-diastolic long rumbling murmur at apex and pansystolic murmur of tricuspid regurgitation at lower left sterna border. Chest X-ray showed evidence of grade 3 pulmonary venous congestion. Transthoracic and transesophageal two-dimensional echocardiography revealed a double-orifice mitral valve of complete bridge type at the leaflet level. Both orifice sizes were unequal, with the anterolateral orifice being smaller than its counterpart. There was moderate subvalvular fusion and both commisures were fused. Color doppler examination showed two separate mitral diastolic flows with mean gradients of 22 mm and 20 mm of Hg, respectively. There was no mitral regurgitation and no left atrial or appendage clot was seen by transesophageal echocardiography. Transseptal puncture was done by the modified fluoroscopic method. Posteromedial orifice was crossed with a 24 mm Inoue balloon and dilated using the stepwise dilation technique. Anterolateral orifice was not crossed by Inuoe balloon after multiple attempts. A TYSHAK (NuMAD Canada Inc.) balloon (16 × 40mm) was taken over the wire and inflated successfully across the anterolateral orifice with the help of transthoracic echocardiography guidance. Mean gradient become 9 and 8 mm across the medial and lateral orifice. Patient was discharged in stable condition after two day. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Chandra, Sonal; Salgo, Ivan S; Sugeng, Lissa; Weinert, Lynn; Settlemier, Scott H; Mor-Avi, Victor; Lang, Roberto M
2011-09-01
Mitral effective regurgitant orifice area (EROA) using the flow convergence (FC) method is used to quantify the severity of mitral regurgitation (MR). However, it is challenging and prone to interobserver variability in complex valvular pathology. We hypothesized that real-time three-dimensional (3D) transesophageal echocardiography (RT3D TEE) derived anatomic regurgitant orifice area (AROA) can be a reasonable adjunct, irrespective of valvular geometry. Our goals were to 1) to determine the regurgitant orifice morphology and distance suitable for FC measurement using 3D computational flow dynamics and finite element analysis (FEA), and (2) to measure AROA from RT3D TEE and compare it with 2D FC derived EROA measurements. We studied 61 patients. EROA was calculated from 2D TEE images using the 2D-FC technique, and AROA was obtained from zoomed RT3DE TEE acquisitions using prototype software. 3D computational fluid dynamics by FEA were applied to 3D TEE images to determine the effects of mitral valve (MV) orifice geometry on FC pattern. 3D FEA analysis revealed that a central regurgitant orifice is suitable for FC measurements at an optimal distance from the orifice but complex MV orifice resulting in eccentric jets yielded nonaxisymmetric isovelocity contours close to the orifice where the assumptions underlying FC are problematic. EROA and AROA measurements correlated well (r = 0.81) with a nonsignificant bias. However, in patients with eccentric MR, the bias was larger than in central MR. Intermeasurement variability was higher for the 2D FC technique than for RT3DE-based measurements. With its superior reproducibility, 3D analysis of the AROA is a useful alternative to quantify MR when 2D FC measurements are challenging.
Flow rate of some pharmaceutical diluents through die-orifices relevant to mini-tableting.
Kachrimanis, K; Petrides, M; Malamataris, S
2005-10-13
The effects of cylindrical orifice length and diameter on the flow rate of three commonly used pharmaceutical direct compression diluents (lactose, dibasic calcium phosphate dihydrate and pregelatinised starch) were investigated, besides the powder particle characteristics (particle size, aspect ratio, roundness and convexity) and the packing properties (true, bulk and tapped density). Flow rate was determined for three different sieve fractions through a series of miniature tableting dies of different orifice diameter (0.4, 0.3 and 0.2 cm) and thickness (1.5, 1.0 and 0.5 cm). It was found that flow rate decreased with the increase of the orifice length for the small diameter (0.2 cm) but for the large diameter (0.4 cm) was increased with the orifice length (die thickness). Flow rate changes with the orifice length are attributed to the flow regime (transitional arch formation) and possible alterations in the position of the free flowing zone caused by pressure gradients arising from the flow of self-entrained air, both above the entrance in the die orifice and across it. Modelling by the conventional Jones-Pilpel non-linear equation and by two machine learning algorithms (lazy learning, LL, and feed-forward back-propagation, FBP) was applied and predictive performance of the fitted models was compared. It was found that both FBP and LL algorithms have significantly higher predictive performance than the Jones-Pilpel non-linear equation, because they account both dimensions of the cylindrical die opening (diameter and length). The automatic relevance determination for FBP revealed that orifice length is the third most influential variable after the orifice diameter and particle size, followed by the bulk density, the difference between bulk and tapped densities and the particle convexity.
Granular flow in silos with moving exit
NASA Astrophysics Data System (ADS)
To, Kiwing
2017-11-01
We conducted granular flow experiments of mono-disperse plastic beads falling out of a cylindrical silos through a circular orifice at the bottom. When the diameter of the orifice is about twice that of the beads, no finite flow rate can be sustained because of clogging at the orifice. We constructed a silo with a bottom that can rotate with respect to the wall of the silo. Then one can rotate the bottom of the silo so that the orifice can rotate (or move in a circle if the orifice is off centered) with respect to the beads. In such a silo with rotating bottom, a finite flow rate can be sustained. While the flow rate Q depends on the angular frequency ω of the rotating bottom as well as the distance R of the orifice from the axis of the silo, Q at different ω and R can be collapsed to a single curve when Q when plotted against the product of ω and R. Nankang, Taipei, Taiwan 11529.
Method for gas-metal arc deposition
Buhrmaster, C.L.; Clark, D.E.; Smartt, H.B.
1990-11-13
Method and apparatus for gas-metal arc deposition of metal, metal alloys, and metal matrix composites are disclosed. The apparatus contains an arc chamber for confining a D.C. electrical arc discharge, the arc chamber containing an outlet orifice in fluid communication with a deposition chamber having a deposition opening in alignment with the orifice for depositing metal droplets on a coatable substrate. Metal wire is passed continuously into the arc chamber in alignment with the orifice. Electric arcing between the metal wire anode and the orifice cathode produces droplets of molten metal from the wire which pass through the orifice and into the deposition chamber for coating a substrate exposed at the deposition opening. When producing metal matrix composites, a suspension of particulates in an inert gas enters the deposition chamber via a plurality of feed openings below and around the orifice so that reinforcing particulates join the metal droplets to produce a uniform mixture which then coats the exposed substrate with a uniform metal matrix composite. 1 fig.
Method for gas-metal arc deposition
Buhrmaster, Carol L.; Clark, Denis E.; Smartt, Herschel B.
1990-01-01
Method and apparatus for gas-metal arc deposition of metal, metal alloys, and metal matrix composites. The apparatus contains an arc chamber for confining a D.C. electrical arc discharge, the arc chamber containing an outlet orifice in fluid communication with a deposition chamber having a deposition opening in alignment wiht the orifice for depositing metal droplets on a coatable substrate. Metal wire is passed continuously into the arc chamber in alignment with the orifice. Electric arcing between the metal wire anode and the orifice cathode produces droplets of molten metal from the wire which pass through the orifice and into the deposition chamber for coating a substrate exposed at the deposition opening. When producing metal matrix composites, a suspension of particulates in an inert gas enters the deposition chamber via a plurality of feed openings below and around the orifice so that reinforcing particulates join the metal droplets to produce a uniform mixture which then coats the exposed substrate with a uniform metal matrix composite.
Apparatus for gas-metal arc deposition
Buhrmaster, Carol L.; Clark, Denis E.; Smartt, Herschel B.
1991-01-01
Apparatus for gas-metal arc deposition of metal, metal alloys, and metal matrix composites. The apparatus contains an arc chamber for confining a D.C. electrical arc discharge, the arc chamber containing an outlet orifice in fluid communication with a deposition chamber having a deposition opening in alignment with the orifice for depositing metal droplets on a coatable substrate. Metal wire is passed continuously into the arc chamber in alignment with the orifice. Electric arcing between the metal wire anode and the orifice cathode produces droplets of molten metal from the wire which pass through the orifice and into the deposition chamber for coating a substrate exposed at the deposition opening. When producing metal matrix composites, a suspenion of particulates in an inert gas enters the deposition chamber via a plurality of feed openings below and around the orifice so that reinforcing particulates join the metal droplets to produce a uniform mixture which then coats the exposed substrate with a uniform metal matrix composite.
Experiments in dilution jet mixing effects of multiple rows and non-circular orifices
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Srinivasan, R.; Coleman, E. B.; Meyers, G. D.; White, C. D.
1985-01-01
Experimental and empirical model results are presented that extend previous studies of the mixing of single-sided and opposed rows of jets in a confined duct flow to include effects of non-circular orifices and double rows of jets. Analysis of the mean temperature data obtained in this investigation showed that the effects of orifice shape and double rows are significant only in the region close to the injection plane, provided that the orifices are symmetric with respect to the main flow direction. The penetration and mixing of jets from 45-degree slanted slots is slightly less than that from equivalent-area symmetric orifices. The penetration from 2-dimensional slots is similar to that from equivalent-area closely-spaced rows of holes, but the mixing is slower for the 2-D slots. Calculated mean temperature profiles downstream of jets from non-circular and double rows of orifices, made using an extension developed for a previous empirical model, are shown to be in good agreement with the measured distributions.
Experiments in dilution jet mixing - Effects of multiple rows and non-circular orifices
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Srinivasan, R.; Coleman, E. B.; Meyers, G. D.; White, C. D.
1985-01-01
Experimental and empirical model results are presented that extend previous studies of the mixing of single-sided and opposed rows of jets in a confined duct flow to include effects of non-circular orifices and double rows of jets. Analysis of the mean temperature data obtained in this investigation showed that the effects of orifice shape and double rows are significant only in the region close to the injection plane, provided that the orifices are symmetric with respect to the main flow direction. The penetration and mixing of jets from 45-degree slanted slots is slightly less than that from equivalent-area symmetric orifices. The penetration from two-dimensional slots is similar to that from equivalent-area closely-spaced rows of holes, but the mixing is slower for the 2-D slots. Calculated mean temperature profiles downstream of jets from non-circular and double rows of orifices, made using an extension developed for a previous empirical model, are shown to be in good agreement with the measured distributions.
Displacement of ureteral orifices following anterior colporrhaphy.
Dain, Lena; Auslander, Ron; Lissak, Arie; Lavie, Ofer; Abramov, Yoram
2010-01-01
It is currently unknown whether ureteral orifices maintain their anatomic location after reconstructive pelvic surgeries. We therefore aimed to assess ureteral orifices' location after anterior colporrhaphy. Between August and December 2007, patients undergoing anterior colporrhaphy for advanced cystocele in our institution underwent cystoscopy with intravenous dye injection and placement of ureteral catheters before and after the surgery. Each ureteral orifice location was marked on an X-Y coordinate on the posterior bladder wall before and after surgery. Thirteen women aged 44-80 years were included in the study. Postoperatively, ureteral orifices were noted to migrate 0.65 +/- 0.3 cm caudally (closer to the urethrovesical junction) (p = 0.002) and 0.32 +/- 0.5 cm laterally (p < 0.05). Anterior colporrhaphy is associated with significant caudal and lateral displacement of both ureteral orifices. These findings are of potential importance for pelvic reconstructive surgeons and may facilitate faster cystoscopic evaluation of ureteral patency postoperatively. They may also have implications on the angle of the preferred optical equipment to be used.
Optimization of Orifice Geometry for Cross-Flow Mixing in a Cylindrical Duct
NASA Technical Reports Server (NTRS)
Kroll, J. T.; Sowa, W. A.; Samuelsen, G. S.
1996-01-01
Mixing of gaseous jets in a cross-flow has significant applications in engineering, one example of which is the dilution zone of a gas turbine combustor. Despite years of study, the design of the jet injection in combustors is largely based on practical experience. The emergence of NO(x) regulations for stationary gas turbines and the anticipation of aero-engine regulations requires an improved understanding of jet mixing as new combustor concepts are introduced. For example, the success of the staged combustor to reduce the emission of NO(x) is almost entirely dependent upon the rapid and complete dilution of the rich zone products within the mixing section. It is these mixing challenges to which the present study is directed. A series of experiments was undertaken to delineate the optimal mixer orifice geometry. A cross-flow to core-flow momentum-flux ratio of 40 and a mass flow ratio of 2.5 were selected as representative of a conventional design. An experimental test matrix was designed around three variables: the number of orifices, the orifice length-to- width ratio, and the orifice angle. A regression analysis was performed on the data to arrive at an interpolating equation that predicted the mixing performance of orifice geometry combinations within the range of the test matrix parameters. Results indicate that the best mixing orifice geometry tested involves eight orifices with a long-to-short side aspect ratio of 3.5 at a twenty-three degree inclination from the center-line of the mixing section.
Rajwani, Adil; Shirazi, Masoumeh G; Disney, Patrick J S; Wong, Dennis T L; Teo, Karen S L; Delacroix, Sinny; Chokka, Ramesh G; Young, Glenn D; Worthley, Stephen G
2015-12-01
Predictors of residual leak following percutaneous LAA closure were evaluated. Left atrial appendage (LAA) closure aims to exclude this structure from the circulation, typically using a circular occluder. A noncircular orifice is frequently encountered however, and fibrous remodeling of the LAA in atrial fibrillation may restrict orifice deformation. Noncircularity may thus be implicated in the occurrence of residual leak despite an appropriately oversized device. Pre-procedural multislice computerized tomography was used to quantify LAA orifice eccentricity and irregularity. Univariate predictors of residual leak were identified with respect to the orifice, device, and relevant clinical variables, with the nature of any correlations then further evaluated. Eccentricity and irregularity indexes of the orifice in 31 individuals were correlated with residual leak even where the device was appropriately oversized. An eccentricity index of 0.15 predicted a residual leak with 85% sensitivity and 59% specificity. An irregularity index of 0.05 predicted a significant residual leak ≥3 mm with 100% sensitivity and 86% specificity. Orifice size, device size, degree of device oversize, left atrial volume, and pulmonary artery pressure were not predictors of residual leak. Eccentricity and irregularity of the LAA orifice are implicated in residual leak after percutaneous closure even where there is appropriate device over-size. Irregularity index in particular is a novel predictor of residual leak, supporting a closer consideration of orifice morphology before closure. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Pressure atomizer having multiple orifices and turbulent generation feature
VanBrocklin, Paul G.; Geiger, Gail E.; Moran, Donald James; Fournier, Stephane
2002-01-01
A pressure atomizer includes a silicon plate having a top surface and a bottom surface. A portion of the top surface defines a turbulent chamber. The turbulent chamber is peripherally bounded by the top surface of the plate. The turbulent chamber is recessed a predetermined depth relative to the top surface. The silicon plate further defines at least one flow orifice. Each flow orifice extends from the bottom surface of the silicon plate to intersect with and open into the turbulent chamber. Each flow orifice is in fluid communication with the turbulent chamber.
NASA Technical Reports Server (NTRS)
Holdeman, James D.; Liscinsky, David S.; Bain, Daniel B.
1997-01-01
This paper summarizes experimental and computational results on the mixing of opposed rows of jets with a confined subsonic crossflow in rectangular ducts. The studies from which these results were excerpted investigated flow and geometric variations typical of the complex 3-D flowfield in the combustion chambers in gas turbine engines. The principal observation was that the momentum-flux ratio, J, and the orifice spacing, S/H, were the most significant flow and geometric variables. Jet penetration was critical, and penetration decreased as either momentum-flux ratio or orifice spacing decreased. It also appeared that jet penetration remained similar with variations in orifice size, shape, spacing, and momentum-flux ratio when the orifice spacing was inversely proportional to the square-root of the momentum-flux ratio. It was also seen that planar averages must be considered in context with the distributions. Note also that the mass-flow ratios and the offices investigated were often very large (jet-to-mainstream mass-flow ratio greater than 1 and the ratio of orifices-area-to-mainstream-cross-sectional-area up to 0.5 respectively), and the axial planes of interest were often just downstream of the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations.
Investigation of the sound generation mechanisms for in-duct orifice plates.
Tao, Fuyang; Joseph, Phillip; Zhang, Xin; Stalnov, Oksana; Siercke, Matthias; Scheel, Henning
2017-08-01
Sound generation due to an orifice plate in a hard-walled flow duct which is commonly used in air distribution systems (ADS) and flow meters is investigated. The aim is to provide an understanding of this noise generation mechanism based on measurements of the source pressure distribution over the orifice plate. A simple model based on Curle's acoustic analogy is described that relates the broadband in-duct sound field to the surface pressure cross spectrum on both sides of the orifice plate. This work describes careful measurements of the surface pressure cross spectrum over the orifice plate from which the surface pressure distribution and correlation length is deduced. This information is then used to predict the radiated in-duct sound field. Agreement within 3 dB between the predicted and directly measured sound fields is obtained, providing direct confirmation that the surface pressure fluctuations acting over the orifice plates are the main noise sources. Based on the developed model, the contributions to the sound field from different radial locations of the orifice plate are calculated. The surface pressure is shown to follow a U 3.9 velocity scaling law and the area over which the surface sources are correlated follows a U 1.8 velocity scaling law.
A New Electrospray Aerosol Generator with High Particle Transmission Efficiency
Fu, Huijing; Patel, Anand C.; Holtzman, Michael J.; Chen, Da-Ren
2012-01-01
A new single-capillary electrospray (ES) aerosol generator has been developed for monodisperse particle production with maximal transmission efficiency. The new generator consists of both a spray chamber in a point-to-orifice-plate configuration and a charge reduction chamber that can hold up to 4 Nuclespot ionizers (Model P-2042, NRD Inc.). The 2 chambers are partitioned by an orifice plate. To optimize the particle transmission efficiency of the prototype, a systematic study was performed on the generator by varying the system setup and operation. Two key dimensions of the generator setup, the orifice diameter and the distance from the capillary tip to the orifice plate, were varied. Fluorescence analysis was applied to characterize the loss of ES-generated particles at different locations of the prototype. It was found that particle loss in the generator could be reduced by either increasing the orifice diameter or decreasing the distance between the capillary tip and the orifice plate. Increasing either the total radioactivity of the ionizers or the flowrate of the particle carrier gas also further decreased the particle loss in the system. The maximum particle transmission efficiency of 88.0% was obtained with the spray chamber fully opened to the charge reduction chamber, the capillary tip at the same level as the orifice plate, and 4 bipolar ionizers installed. PMID:22829715
A theoretical study of the acoustic impedance of orifices in the presence of a steady grazing flow
NASA Technical Reports Server (NTRS)
Rice, E. J.
1976-01-01
An analysis of the oscillatory fluid flow in the vicinity of a circular orifice with a steady grazing flow is presented. The study is similar to that of Hersh and Rogers but with the addition of the grazing flow. Starting from the momentum and continuity equations, a considerably simplified system of partial differential equations is developed with the assumption that the flow can be described by an oscillatory motion superimposed upon the known steady flow. The equations are seen to be linear in the region where the grazing flow effects are dominant, and a solution and the resulting orifice impedance are presented for this region. The nonlinearity appears to be unimportant for the usual conditions found in aircraft noise suppressors. Some preliminary conclusions of the study are that orifice resistance is directly proportional to grazing flow velocity (known previously from experimental data) and that the orifice inductive (mass reactance) end correction is not a function of grazing flow. This latter conclusion is contrary to the widely held notion that grazing flow removes the effect of the orifice inductive end correction. This conclusion also implies that the experimentally observed total inductance reduction with grazing flow might be in the flow within the orifice rather than in the end correction.
Distortion Of Pressure Signals In Pneumatic Tubes
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William
1993-01-01
NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.
Process for depositing hard coating in a nozzle orifice
Flynn, P.L.; Giammarise, A.W.
1991-10-29
The present invention is directed to a process for coating the interior surfaces of an orifice in a substrate that forms a slurry fuel injection nozzle. In a specific embodiment, the nozzle is part of a fuel injection system for metering a coal-water slurry into a large, medium-speed, multi-cylinder diesel engine. In order to retard erosion of the orifice, the substrate is placed in a chemical vapor deposition (CVD) reaction chamber. A reaction gas is passed into the chamber at a gas temperature below its reaction temperature and is directed through the orifice in the substrate. The gas reaction temperature is a temperature at and above which the reaction gas deposits as a coating, and the reaction gas is of a composition whereby improved resistance to erosion by flow of the particulates in the slurry fuel is imparted by the deposited coating. Only the portion of the substrate in proximity to the orifice to be coated is selectively heated to at least the gas reaction temperature for effecting coating of the orifice's interior surfaces by the vapor deposited coating formed from the reaction gas. 2 figures.
Apparatus for depositing hard coating in a nozzle orifice
Flynn, Paul L.; Giammarise, Anthony W.
1995-01-01
The present invention is directed to a process for coating the interior surfaces of an orifice in a substrate that forms a slurry fuel injection nozzle. In a specific embodiment, the nozzle is part of a fuel injection system for metering a coal-water slurry into a large, medium-speed, multi-cylinder diesel engine. In order to retard erosion of the orifice, the substrate is placed in a chemical vapor deposition (CVD) reaction chamber. A reaction gas is passed into the chamber at a gas temperature below its reaction temperature and is directed through the orifice in the substrate. The gas reaction temperature is a temperature at and above which the reaction gas deposits as a coating, and the reaction gas is of a composition whereby improved resistance to erosion by flow of the particulates in the slurry fuel is imparted by the deposited coating. Only the portion of the substrate in proximity to the orifice to be coated is selectively heated to at least the gas reaction temperature for effecting coating of the orifice's interior surfaces by the vapor deposited coating formed from the reaction gas.
Apparatus and process for depositing hard coating in a nozzle orifice
Flynn, Paul L.; Giammarise, Anthony W.
1994-01-01
The present invention is directed to a process for coating the interior surfaces of an orifice in a substrate that forms a slurry fuel injection nozzle. In a specific embodiment, the nozzle is part of a fuel injection system for metering a coal-water slurry into a large, medium-speed, multi-cylinder diesel engine. In order to retard erosion of the orifice, the substrate is placed in a chemical vapor deposition (CVD) reaction chamber. A reaction gas is passed into the chamber at a gas temperature below its reaction temperature and is directed through the orifice in the substrate. The gas reaction temperature is a temperature at and above which the reaction gas deposits as a coating, and the reaction gas is of a composition whereby improved resistance to erosion by flow of the particulates in the slurry fuel is imparted by the deposited coating. Only the portion of the substrate in proximity to the orifice to be coated is selectively heated to at least the gas reaction temperature for effecting coating of the orifice's interior surfaces by the vapor deposited coating formed from the reaction gas.
Process for depositing hard coating in a nozzle orifice
Flynn, Paul L.; Giammarise, Anthony W.
1991-01-01
The present invention is directed to a process for coating the interior surfaces of an orifice in a substrate that forms a slurry fuel injection nozzle. In a specific embodiment, the nozzle is part of a fuel injection system for metering a coal-water slurry into a large, medium-speed, multi-cylinder diesel engine. In order to retard erosion of the orifice, the substrate is placed in a chemical vapor deposition (CVD) reaction chamber. A reaction gas is passed into the chamber at a gas temperature below its reaction temperature and is directed through the orifice in the substrate. The gas reaction temperature is a temperature at and above which the reaction gas deposits as a coating, and the reaction gas is of a composition whereby improved resistance toerosion by flow of the particulates in the slurry fuel is imparted by the deposited coating. Only the portion of the substrate in proximity to the orifice to be coated is selectively heated to at least the gas reaction temperature for effecting coating of the orifice's interior surfaces by the vapor deposited coating formed from the reaction gas.
Flow balancing orifice for ITER toroidal field coil
NASA Astrophysics Data System (ADS)
Litvinovich, A. V.; Y Rodin, I.; Kovalchuk, O. A.; Safonov, A. V.; Stepanov, D. B.; Guryeva, T. M.
2017-12-01
Flow balancing orifices (FBOs) are used in in International thermonuclear experimental reactor (ITER) Toroidal Field coil to uniform flow rate of cooling gas in the side double pancakes which have a different conductor length: 99 m and 305 m, respectively. FBOs consist of straight parts, elbows produced from a 316L stainless steel tube 21.34 x 2.11 mm and orifices made from a 316L stainless steel rod. Each of right and left FBOs contains 6 orifices, straight FBOs contain 4 and 6 orifices. Before manufacturing of qualification samples D.V. Efremov Institute of Electrophysical Apparatus (JSC NIIEFA) proposed to ITER a new approach to provide the seamless connection between a tube and a plate therefore the most critical weld between the orifice with 1 mm thickness and the tube removed from the FBOs final design. The proposed orifice diameter is three times less than the minimum requirement of the ISO 5167, therefore it was tasked to define accuracy of calculation flow characteristics at room temperature and compare with the experimental data. In 2015 the qualification samples of flow balancing orifices were produced and tested. The results of experimental data showed that the deviation of calculated data is less than 7%. Based on this result and other tests ITER approved the design of FBOs, which made it possible to start the serial production. In 2016 JSC NIIEFA delivered 50 FBOs to ITER, i.e. 24 left side, 24 right side and 2 straight FBOs. In order to define the quality of FBOs the test facility in JSC NIIEFA was prepared. The helium tightness test at 10-9 m3·Pa/s the pressure up to 3 MPa, flow rate measuring at the various pressure drops, the non-destructive tests of orifices and weld seams (ISO 5817, class B) were conducted. Other tests such as check dimensions and thermo cycling 300 - 80 - 300 K also were carried out for each FBO.
[Fourth branchial cleft deformity with skin orifice: a series of 10 cases].
Huang, S L; Zhang, B; Chen, L S; Liang, L; Luo, X N; Lu, Z M; Zhang, S Y
2016-10-07
Objective: To report rare cases of congenital neck cutaneous sinus with an orifice near the sternoclavicular joint and to investigate their origins and managements. Methods: A total of ten patients with congenital neck cutaneous sinus having an orifice near the sternoclavicular joint treated in the Guangdong General Hospital from January 2010 to June 2015 were retrospectively analyzed. Results: There four boys and six girls, aging from 11 months to 96 months with an average of 33.4 months, and they had a common feature showing a congenital cutaneous sinus with an orifice near sternoclavicular joint. Discharge of pus from the orifice or abscess formation was commonly seen soon after infection. With bacteriological study, staphylococcus aureus was positive in five cases and klebsiella pneumonia in a case. Another orifice of fistula/sinus was not depicted in pyriform with barium swallow X-ray in five cases Ultrasound studies of three cases demonstrated anechoic (i.e., nearly black) and solid-cystic lesion near sternoclavicular joint with posterior acoustic enhancement. Magnetic resonance imaging (MRI) showed isointensity of the lesion on T1 and T2 weighted images with heterogeneous enhancement and a close relationship with sternoclavicular joint. All patients underwent laryngoscopic examination, which showed no orifice of sinus in pyriform at same side. Surgical resection of fistula/sinus was performed in all cases. The lengths of the fistula varied from 5 mm to 22 mm with an average of 11 mm. Postoperative pathological examination showed all specimens were accordance with fistula. No complications were noticed. Recurrence was not observed in the cases by following-up of 6 months to 70 months (median: 33 months). Conclusion: Congenital neck cutaneous sinus with orifice near the sternoclavicular joint maybe a special clinical phenotype of the fourth branchial cleft sinus with skin orifice in cervicothoracic junction. Differential diagnoses between low cervical diseases are required. The curative treatment is a complete excision during inflammatory quiescent period.
Ebacher, G; Besner, M C; Clément, B; Prévost, M
2012-09-01
Intrusion events caused by transient low pressures may result in the contamination of a water distribution system (DS). This work aims at estimating the range of potential intrusion volumes that could result from a real downsurge event caused by a momentary pump shutdown. A model calibrated with transient low pressure recordings was used to simulate total intrusion volumes through leakage orifices and submerged air vacuum valves (AVVs). Four critical factors influencing intrusion volumes were varied: the external head of (untreated) water on leakage orifices, the external head of (untreated) water on submerged air vacuum valves, the leakage rate, and the diameter of AVVs' outlet orifice (represented by a multiplicative factor). Leakage orifices' head and AVVs' orifice head levels were assessed through fieldwork. Two sets of runs were generated as part of two statistically designed experiments. A first set of 81 runs was based on a complete factorial design in which each factor was varied over 3 levels. A second set of 40 runs was based on a latin hypercube design, better suited for experimental runs on a computer model. The simulations were conducted using commercially available transient analysis software. Responses, measured by total intrusion volumes, ranged from 10 to 366 L. A second degree polynomial was used to analyze the total intrusion volumes. Sensitivity analyses of both designs revealed that the relationship between the total intrusion volume and the four contributing factors is not monotonic, with the AVVs' orifice head being the most influential factor. When intrusion through both pathways occurs concurrently, interactions between the intrusion flows through leakage orifices and submerged AVVs influence intrusion volumes. When only intrusion through leakage orifices is considered, the total intrusion volume is more largely influenced by the leakage rate than by the leakage orifices' head. The latter mainly impacts the extent of the area affected by intrusion. Copyright © 2012 Elsevier Ltd. All rights reserved.
Analysis and Design of a Double-Divert Spiral Groove Seal
NASA Technical Reports Server (NTRS)
Zheng, Xiaoqing; Berard, Gerald
2007-01-01
This viewgraph presentation describes the design and analysis of a double spiral groove seal. The contents include: 1) Double Spiral Design Features; 2) Double Spiral Operational Features; 3) Mating Ring/Rotor Assembly; 4) Seal Ring Assembly; 5) Insert Segment Joints; 6) Rotor Assembly Completed Prototype Parts; 7) Seal Assembly Completed Prototype Parts; 8) Finite Element Analysis; 9) Computational Fluid Dynamics (CFD) Analysis; 10) Restrictive Orifice Design; 11) Orifice CFD Model; 12) Orifice Results; 13) Restrictive Orifice; 14) Seal Face Coning; 15) Permanent Magnet Analysis; 16) Magnetic Repulsive Force; 17) Magnetic Repulsive Test Results; 18) Spin Testing; and 19) Testing and Validation.
In-situ control system for atomization
Anderson, I.E.; Figliola, R.S.; Terpstra, R.L.
1995-06-13
Melt atomizing apparatus comprising a melt supply orifice for supplying the melt for atomization and gas supply orifices proximate the melt supply orifice for supplying atomizing gas to atomize the melt as an atomization spray is disclosed. The apparatus includes a sensor, such as an optical and/or audio sensor, for providing atomization spray data, and a control unit responsive to the sensed atomization spray data for controlling at least one of the atomizing gas pressure and an actuator to adjust the relative position of the gas supply orifice and melt supply in a manner to achieve a desired atomization spray. 3 figs.
In-situ control system for atomization
Anderson, Iver E.; Figliola, Richard S.; Terpstra, Robert L.
1995-06-13
Melt atomizing apparatus comprising a melt supply orifice for supplying the melt for atomization and gas supply orifices proximate the melt supply orifice for supplying atomizing gas to atomize the melt as an atomization spray. The apparatus includes a sensor, such as an optical and/or audio sensor, for providing atomization spray data, and a control unit responsive to the sensed atomization spray data for controlling at least one of the atomizing gas pressure and an actuator to adjust the relative position of the gas supply orifice and melt supply in a manner to achieve a desired atomization spray.
Calibrated permeation standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dameron, Arrelaine A.; Reese, Matthew O.; Kempe, Michael D.
2017-11-21
A permeation standard is provided. The permeation standard may include a substrate that is impermeable to an analyte, an orifice disposed in the substrate, and a permeable material filling the orifice. The orifice and the permeable material are configured to provide a predetermined transmission rate of the analyte through the permeation standard. Also provided herein are methods for forming the permeation standard.
Okandan, Murat; Galambos, Paul
2007-11-06
A micromachined spinneret is disclosed which has one or more orifices through which a fiber-forming material can be extruded to form a fiber. Each orifice is surrounded by a concentric annular orifice which allows the fiber to be temporarily or permanently coated with a co-extrudable material. The micromachined spinneret can be formed by a combination of surface and bulk micromachining.
CFD Assessment of Orifice Aspect Ratio and Mass Flow Ratio on Jet Mixing in Rectangular Ducts
NASA Technical Reports Server (NTRS)
Bain, D. B.; Smith, C. E.; Holdeman, J. D.
1994-01-01
Isothermal CFD analysis was performed on axially opposed rows of jets mixing with cross flow in a rectangular duct. Laterally, the jets' centerlines were aligned with each other on the top and bottom walls. The focus of this study was to characterize the effects of orifice aspect ratio and jet-to-mainstream mass flow ratio on jet penetration and mixing. Orifice aspect ratios (L/W) of 4-to-1, 2-to-1, and 1-to-1, along with circular holes, were parametrically analyzed. Likewise, jet-to-mainstream mass flow ratios (MR) of 2.0, 0.5, and 0.25 were systematically investigated. The jet-to-mainstream momentum-flux ratio (J) was maintained at 36 for all cases, and the orifice spacing-to-duct height (S/H) was varied until optimum mixing was attained for each configuration. The numerical results showed that orifice aspect ratio (and likewise orifice blockage) had little effect on jet penetration and mixing. Based on mixing characteristics alone, the 4-to-1 slot was comparable to the circular orifice. The 4-to-1 slot has a smaller jet wake which may be advantageous for reducing emissions. However, the axial length of a 4-to-1 slot may be prohibitively long for practical application, especially for MR of 2.0. The jet-to-mainstream mass flow ratio had a more significant effect on jet penetration and mixing. For a 4-to-1 aspect ratio orifice, the design correlating parameter for optimum mixing (C = (S/H)(sq. root J)) varied from 2.25 for a mass flow ratio of 2.0 to 1.5 for a mass flow ratio of 0.25.
Reduction of Secondary Flow in Inclined Orifice Pulse Tubes by Addition of DC Flow
NASA Astrophysics Data System (ADS)
Shiraishi, M.; Fujisawa, Y.; Murakami, M.; Nanako, A.
2004-06-01
The effect of using a second orifice valve to reduce convective losses caused by gravity-driven convective secondary flow in inclined orifice pulse tube refrigerators was investigated. The second orifice valve was installed between a reservoir and a low-pressure line of a compressor. When the valve was open, an additional DC flow directed to the hot end of the refrigerator was generated to counterbalance the convective secondary flow in the core region by opening the valve. Experimental results indicated that with increasing additional DC flow to an optimum level, the convective secondary flow decreased and the cooling performance improved, although further increase of the DC flow over the level caused the cooling performance to degrade. In summary, the second orifice valve was effective in reducing both the convective losses without affecting the cooling performance at an inclination angle < 70° where convective losses were negligibly small.
Material transport method and apparatus
Ramsey, J. Michael; Ramsey, Roswitha S.
2000-01-01
An electrospray apparatus uses a microchannel formed in a microchip. Fluid is pumped through the channel to an outlet orifice using either hydraulic or electrokinetic means. An electrospray is generated by establishing a sufficient potential difference between the fluid at the outlet orifice and a target electrode spaced from the outlet orifice. Electrokinetic pumping is also utilized to provide additional benefits to microchip devices.
Material transport method and apparatus
Ramsey, J. Michael; Ramsey, Roswitha S.
2001-01-01
An electrospray apparatus uses a microchannel formed in a microchip. Fluid is pumped through the channel to an outlet orifice using either hydraulic or electrokinetic means. An electrospray is generated by establishing a sufficient potential difference between the fluid at the outlet orifice and a target electrode spaced from the outlet orifice. Electrokinetic pumping is also utilized to provide additional benefits to microchip devices.
Feng, Daolun; Zhao, Jie; Liu, Tian
2016-01-01
The discharge of alien ballast water is a well-known, major reason for marine species invasion. Here, circular orifice plate-generated hydrodynamic cavitation was used to inactivate Heterosigma akashiwo in ballast water. In comparison with single- and multihole orifice plates, the conical-hole orifice plate yielded the highest inactivation percentage, 51.12%, and consumed only 6.84% energy (based on a 50% inactivation percentage). Repeating treatment, either using double series-connection or circling inactivation, elevated the inactivation percentage, yet consumed much more energy. The results indicate that conical-hole-generated hydrodynamic cavitation shows great potential as a pre-inactivation method for ballast water treatment.
Velocity field near the jet orifice of a round jet in a crossflow
NASA Technical Reports Server (NTRS)
Fearn, R. L.; Benson, J. P.
1979-01-01
Experimentally determined velocities at selected locations near the jet orifice are presented and analyzed for a round jet in crossflow. Jet-to-crossflow velocity ratios of four and eight were studied experimentally for a round subsonic jet of air exhausting perpendicularly through a flat plate into a subsonic crosswind of the same temperature. Velocity measurements were made in cross sections to the jet plume located from one to four jet diameters from the orifice. Jet centerline and vortex properties are presented and utilized to extend the results of a previous study into the region close to the jet orifice.
NASA Technical Reports Server (NTRS)
Walker, R. E.; Kors, D. L.
1973-01-01
Test data is presented which allows determination of jet penetration and mixing of multiple cold air jets into a ducted subsonic heated mainstream flow. Jet-to-mainstream momentum flux ratios ranged from 6 to 60. Temperature profile data is presented at various duct locations up to 24 orifice diameters downstream of the plane of jet injection. Except for two configurations, all geometries investigated had a single row of constant diameter orifices located transverse to the main flow direction. Orifice size and spacing between orifices were varied. Both of these were found to have a significant effect on jet penetration and mixing. The best mixing of the hot and cold streams was achieved with duct height.
NASA Technical Reports Server (NTRS)
Florschuetz, L. W.; Metzger, D. E.; Truman, C. R.
1981-01-01
Correlations for heat transfer coefficients for jets of circular offices and impinging on a surface parallel to the jet orifice plate are presented. The air, following impingement, is constrained to exit in a single direction along the channel formed by the jet orifice plate and the heat transfer (impingement) surface. The downstream jets are subjected to a crossflow originating from the upstream jets. Impingement surface heat transfer coefficients resolved to one streamwise jet orifice spacing, averaged across the channel span, are correlated with the associated individual spanwise orifice row jet and crossflow velocities, and with the geometric parameters.
Acoustic Absorption Characteristics of an Orifice With a Mean Bias Flow
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Gaeta, R. J., Jr.; DAgostino, M.; Jones, Mike (Technical Monitor)
2000-01-01
The objective of the study reported here was to acquire acoustic and flow data for numerical validation of impedance models that simulate bias flow through perforates. The impedance model is being developed by researchers at High Technology Corporation. This report documents normal incidence impedance measurements a singular circular orifice with mean flow passing through it. All measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube. The mean flow is introduced upstream of the orifice (with the flow and incident sound wave travelling in the same direction) with an anechoic termination downstream of the orifice. Velocity profiles are obtained upstream of the orifice to characterize the inflow boundary conditions. Velocity in the center of the orifice is also obtained. All velocity measurements are made with a hot wire anemometer and subsequent checked with mass flow measurements made concurrently. All impedance measurements are made using the Two-Microphone Method. Although we have left the analysis of the data to the developers of the impedance models that simulate bias flow through perforate, our initial examination indicates that our results follow the trends consistent with published theory on impedance of perforates with a steady bias flow.
Apparatus and process for depositing hard coating in a nozzle orifice
Flynn, P.L.; Giammarise, A.W.
1994-12-20
The present invention is directed to a process for coating the interior surfaces of an orifice in a substrate that forms a slurry fuel injection nozzle. In a specific embodiment, the nozzle is part of a fuel injection system for metering a coal-water slurry into a large, medium-speed, multi-cylinder diesel engine. In order to retard erosion of the orifice, the substrate is placed in a chemical vapor deposition (CVD) reaction chamber. A reaction gas is passed into the chamber at a gas temperature below its reaction temperature and is directed through the orifice in the substrate. The gas reaction temperature is a temperature at and above which the reaction gas deposits as a coating, and the reaction gas is of a composition whereby improved resistance to erosion by flow of the particulates in the slurry fuel is imparted by the deposited coating. Only the portion of the substrate in proximity to the orifice to be coated is selectively heated to at least the gas reaction temperature for effecting coating of the orifice's interior surfaces by the vapor deposited coating formed from the reaction gas. 2 figures.
Experiments and modeling of dilution jet flow fields
NASA Technical Reports Server (NTRS)
Holdeman, James D.
1986-01-01
Experimental and analytical results of the mixing of single, double, and opposed rows of jets with an isothermal or variable-temperature main stream in a straight duct are presented. This study was performed to investigate flow and geometric variations typical of the complex, three-dimensional flow field in the dilution zone of gas-turbine-engine combustion chambers. The principal results, shown experimentally and analytically, were the following: (1) variations in orifice size and spacing can have a significant effect on the temperature profiles; (2) similar distributions can be obtained, independent of orifice diameter, if momentum-flux ratio and orifice spacing are coupled; (3) a first-order approximation of the mixing of jets with a variable-temperature main stream can be obtained by superimposing the main-stream and jets-in-an-isothermal-crossflow profiles; (4) the penetration of jets issuing mixing is slower and is asymmetric with respect to the jet centerplanes, which shift laterally with increasing downstream distance; (5) double rows of jets give temperature distributions similar to those from a single row of equally spaced, equal-area circular holes; (6) for opposed rows of jets, with the orifice centerlines in line, the optimum ratio of orifice spacing to duct height is one-half the optimum value for single-side injection at the same momentum-flux ratiol and (7) for opposed rows of jets, with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is twice the optimum value for single-side injection at the same momentum-flux ratio.
NASA Technical Reports Server (NTRS)
Moore, J. A.
1979-01-01
An eight orifice probe, designed to protect the transducer without the use of a baffle, was compared to a standard orifice-baffle probe in the small shock tube and in the expansion tube under normal run conditions. In both facilities, the response time of eight orifice probe was considerable better than the standard probe design.
Mixing and NOx Emission Calculations of Confined Reacting Jet Flows in Cylindrical and Annular Ducts
NASA Technical Reports Server (NTRS)
Oechsle, Victor L.; Connor, Christopher H.; Holdeman, James D. (Technical Monitor)
2000-01-01
Rapid mixing of cold lateral jets with hot cross-stream flows in confined configurations is of practical interest in gas turbine combustors as it strongly affects combustor exit temperature quality, and gaseous emissions in for example rich-lean combustion. It is therefore important to further improve our fundamental understanding of the important processes of dilution jet mixing especially when the injected jet mass flow rate exceeds that of the cross-stream. The results reported in this report describe some of the main flow characteristics which develop in the mixing process in a cylindrical duct. A three-dimensional computational fluid dynamics (CFD) code has been used to predict the mixing flow field characteristics and NOx emission in a quench section of a rich-burn/quick-mix/lean-burn (RQL) combustor. Sixty configurations have been analyzed in both circular and annular geometries in a fully reacting environment simulating the operating condition of an actual RQL gas turbine combustion liner. The evaluation matrix was constructed by varying the number of orifices per row and orifice shape. Other parameters such as J (momentum-flux ratio), MR (mass flowrate ratio), DR (density ratio), and mixer sector orifice ACd (effective orifice area) were maintained constant throughout the entire study. The results indicate that the mixing flow field can be correlated with the NOx production if they are referenced with the stoichiometric equivalence ratio value and not the equilibrium value. The mixing flowfields in both circular and annular mixers are different. The penetration of equal jets in both annular and circular geometries is vastly different which significantly affects the performance of the mixing section. In the computational results with the circular mixer, most of the NOx formation occurred behind the orifice starting at the orifice wake region. General trends have been observed in the NOx production as the number of orifices is changed and this appears to be common for all hole configurations and mixer types (circular or annular). The performance of any orifice shape (in producing minimum NOx) appears to be acceptable if the number of orifices can be freely varied in order to attain the optimum jet penetration.
Thrust Measurements of an Underexpanded Orifice in the Transitional Regime
NASA Astrophysics Data System (ADS)
Ketsdever, Andrew D.
2003-05-01
The popularity of micropropulsion system development has led to renewed interest in the determination of propulsive properties of orifice flows since micronozzle expansions may suffer high viscous losses at low pressure operation. The mass flow and relative thrust for an under expanded orifice is measured as a function of orifice stagnation pressure from 0.1 to 3.5 Torr. Nitrogen, argon, and helium propellant gases are passed through a 1.0 mm diameter orifice with a wall thickness of 0.015 mm . Near-free molecule, transitional and continuum flow regimes are studied. The relative thrust is determined by a novel thrust stand designed primarily for low operating pressure, micropropulsion systems. It is shown that the thrust indications obtained from the stand are a function of the facility background pressure, and corrections are made to determine the indicated thrust for a zero background pressure with nitrogen as propellant. Highly repeatable (within 1 %) indicated thrust measurements are obtained in the thrust range from 5 to 500 μN.
Wiegand, D.E.
1962-05-01
A hydraulic servo is designed in which a small pressure difference produced at two orifices by an electrically operated flapper arm in a constantly flowing hydraulic loop is hydraulically amplified by two constant flow pumps, two additional orifices, and three unconnected ball pistons. Two of the pistons are of one size and operate against the additional orifices, and the third piston is of a different size and operates between and against the first two pistons. (AEC)
Impact of L/D on 90 Degree Sharp-Edge Orifice Flow with Manifold Passage Cross Flow (Preprint)
2007-04-30
that are observed by measurement as the flow transitions from non-cavitation to cavitation (turbulent flow), supercavitation , and finally separation in...include inception of cavitation, supercavitation , and separation. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...cavitation to cavitation (turbulent flow), supercavitation , and finally separation in sharp-edge 90 degree orifices. This study includes orifice L/D from
Externally Pressurized Journal Gas Bearings
NASA Technical Reports Server (NTRS)
Laub, John H.
1959-01-01
Externally pressurized gas-lubricated bearings with multiple orifice feed are investigated. An analytical treatment is developed for a semi-cylindrical bearing with 9 orifices and for a cylindrical journal bearing with 192 radial and 24 axial orifices. Experiments are described on models of the two bearing configurations with specially designed fixtures which incorporate pneumatic loading and means for determining pressure profiles, gas flow and gap height. The correlation between theory and experiment is satisfactory.
Influence of the tilt angle of Percutaneous Aortic Prosthesis on Velocity and Shear Stress Fields
Gomes, Bruno Alvares de Azevedo; Camargo, Gabriel Cordeiro; dos Santos, Jorge Roberto Lopes; Azevedo, Luis Fernando Alzuguir; Nieckele, Ângela Ourivio; Siqueira-Filho, Aristarco Gonçalves; de Oliveira, Glaucia Maria Moraes
2017-01-01
Background Due to the nature of the percutaneous prosthesis deployment process, a variation in its final position is expected. Prosthetic valve placement will define the spatial location of its effective orifice in relation to the aortic annulus. The blood flow pattern in the ascending aorta is related to the aortic remodeling process, and depends on the spatial location of the effective orifice. The hemodynamic effect of small variations in the angle of inclination of the effective orifice has not been studied in detail. Objective To implement an in vitro simulation to characterize the hydrodynamic blood flow pattern associated with small variations in the effective orifice inclination. Methods A three-dimensional aortic phantom was constructed, reproducing the anatomy of one patient submitted to percutaneous aortic valve implantation. Flow analysis was performed by use of the Particle Image Velocimetry technique. The flow pattern in the ascending aorta was characterized for six flow rate levels. In addition, six angles of inclination of the effective orifice were assessed. Results The effective orifice at the -4º and -2º angles directed the main flow towards the anterior wall of the aortic model, inducing asymmetric and high shear stress in that region. However, the effective orifice at the +3º and +5º angles mimics the physiological pattern, centralizing the main flow and promoting a symmetric distribution of shear stress. Conclusion The measurements performed suggest that small changes in the angle of inclination of the percutaneous prosthesis aid in the generation of a physiological hemodynamic pattern, and can contribute to reduce aortic remodeling. PMID:28793046
ZhaXi, Yingpai; Wang, Wenhui; Zhang, Wangdong; Gao, Qiang; Guo, Minggang; Jia, Shuai
2014-07-01
The structure and distribution of the mucosa-associated lymphoid tissue (MALT) throughout the large intestine of 10 Bactrian camels were comparatively studied by anatomical and histological methods. The results showed that Peyer's patches (PPs) were mainly located on the mucosal surfaces of the entire ileocecal orifice, the beginning of the cecum and the first third of the colon. The shape of PPs gradually changed from "scrotiform" to "faviform" along the large intestine with the scrotiform PP as the major type in the ileocecal orifice. The distribution density also gradually decreased from the ileocecal orifice to the colon. The histological observations further revealed that the MALT in the form of PPs or isolated lymphoid follicles (ILF) and lamina propria lymphocytes was mainly present in the lamina propria and submucosa from the entire ileocecal orifice, where the muscularis mucosa is usually incomplete, to the colonic forepart. In addition, lymphoid tissue was much more abundant in the lamina propria and submucosa of the ileocecal orifice as compared to the cecum and colon. Statistically, the MALT of the ileocecal orifice contained a higher number of lymphoid follicles (37.7/10 mm(2) ) than that of the cecum, colon, or rectum (P < 0.05). The germinal centers of the lymphoid follicles were clearly visible. Together, our data suggest that the ileocecal orifice constitutes the main inductive site for the mucosal immunity in the large intestine of the Bactrian camel; and that scrotiform PPs are likely to the result of long-term adaptation of the Bactrian camel to the harsh living environment. © 2014 Wiley Periodicals, Inc.
Mixing of Multiple Jets With a Confined Subsonic Crossflow
NASA Technical Reports Server (NTRS)
Holdeman, James D.
1998-01-01
Results from a recently completed enhanced mixing program are summarized in the two technical papers. These studies were parts of a High Speed Research (HSR)-supported joint Government/industry/university program that involved, in addition to the NASA Lewis Research Center, researchers at United Technologies Research Center, Allison Engine Company, CFD Research Corporation, and the University of California, Irvine. The studies investigated the mixing of jets injected normal to a confined subsonic mainsteam in both rectangular and cylindrical ducts. Experimental and computational studies were performed in both nonreacting and reacting flows. The orifice geometries and flow conditions were selected as typical of the complex three-dimensional flows in the combustion chambers in low-emission gas turbine engines. The principal conclusion from both the experiments and modeling was that the momentum-flux ratio J and orifice spacing S/H were the most significant flow and geometry variables, respectively. Conserved scalar distributions were similar-independent of reaction, orifice diameter H/d, and shape-when the orifice spacing and the square root of the momentum-flux ratio were inversely proportional. Jet penetration was critical, and penetration decreased as either momentum-flux ratio or orifice spacing decreased. We found that planar averages must be considered in context with the distributions. The mass-flow ratios and the orifices investigated were often very large. The jet-to-mainstream mass-flow ratio was varied from significantly less than 1 to greater than 1. The orifice-area to mainstream-cross-sectional-area was varied from approx. 0 to 0.5, and the axial planes of interest were often just downstream of the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations. As an example of the results, the accompanying figure shows the effects of different rates of mass addition on the opposite walls of a rectangular duct.
Improved Orifice Plate for Spray Gun
NASA Technical Reports Server (NTRS)
Cunningham, W.
1986-01-01
Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.
Dilution jet mixing program, supplementary report
NASA Technical Reports Server (NTRS)
Srinivasan, R.; White, C.
1986-01-01
The velocity and temperature distributions predicted by a 3-D numerical model and experimental measurements are compared. Empirical correlations for the jet velocity trajectory developed are presented. The measured velocity distributions for all test cases of phase through phase 3 are presented in the form of contour and oblique plots. quantification of the effects of the following on the jet mixing characteristics with a confined crossflow are: (1) orifice geometry momentum flux ratio and density ratio; (2) nonuniform mainstream temperature and velocity profiles upstream of dilution orifices; (3) cold versus hot jet injection; (4) cross-stream flow are a convergence as encountered in practical dilution zone geometries; (5) 2-D slot versus circular orifices; (6) discrete noncirculcer orifices; (7) single-sided versus opposed jets; (8) single row of jets.
Mixing of Multiple Jets with a Confined Subsonic Crossflow in a Cylindrical Duct
NASA Technical Reports Server (NTRS)
Holdeman, James D.; Liscinsky, David S.; Samuelsen, G. Scott; Smith, Clifford E.; Oechsle, Victor L.
1996-01-01
This paper summarizes NASA-supported experimental and computational results on the mixing of a row of jets with a confined subsonic crossflow in a cylindrical duct. The studies from which these results were derived investigated flow and geometric variations typical of the complex 3-D flowfield in the combustion chambers in gas turbine engines. The principal observations were that the momentum-flux ratio and the number of orifices were significant variables. Jet penetration was critical, and jet penetration decreased as either the number of orifices increased or the momentum-flux ratio decreased. It also appeared that jet penetration remained similar with variations in orifice size, shape, spacing, and momentum-flux ratio when the number of orifices was proportional to the square-root of the momentum-flux ratio. In the cylindrical geometry, planar variances are very sensitive to events in the near wall region, so planar averages must be considered in context with the distributions. The mass-flow ratios and orifices investigated were often very large (mass-flow ratio greater than 1 and ratio of orifice area-to-mainstream cross-sectional area up to 0.5), and the axial planes of interest were sometimes near the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations. The results shown also seem to indicate that non-reacting dimensionless scalar profiles can emulate the reacting flow equivalence ratio distribution reasonably well. The results cited suggest that further study may not necessarily lead to a universal 'rule of thumb' for mixer design for lowest emissions, because optimization will likely require an assessment for a specific application.
NASA Technical Reports Server (NTRS)
Holdemann, James D.; Chang, Clarence T.
2008-01-01
This study was motivated by a goal to understand the mixing and emissions in the Rich-burn/Quick-mix/Lean-burn (RQL) combustor scheme that has been proposed to minimize the formation of oxides of nitrogen (NOx) in gas turbine combustors. The study reported herein was a reacting jet-in-crossflow experiment at atmospheric pressure. The jets were injected from the perimeter of a cylindrical duct through round-hole orifices into a fuel-rich mainstream flow. The number of orifices investigated in this study gave over- to optimum to underpenetrating jets at a jet-to-mainstream momentum-flux ratio of J = 57. The size of individual orifices was decreased as the number of orifices increased to maintain a constant total area; the jet-to-mainstream mass-flow ratio was constant at MR = 2.5. The experiments focused on the effects of the number of orifices and inlet air preheat and were conducted in a facility that provided the capability for independent variation of jet and main inlet air preheat temperature. The number of orifices was found to have a significant effect on mixing and the distributions of species, but very little effect on overall NOx emissions, suggesting that an aerodynamically optimum mixer might not minimize NOx emissions. Air preheat was found to have very little effect on mixing and the distributions of major species, but preheating both main and jet air did increase NOx emissions significantly. Although the air jets injected in the quick-mix section of an RQL combustor may comprise over 70 percent of the total air flow, the overall NOx emission levels were found to be more sensitive to main stream air preheat than to jet stream air preheat.
Load dependence of the effective regurgitant orifice area in a sheep model of aortic regurgitation.
Reimold, S C; Byrne, J G; Caguioa, E S; Lee, C C; Laurence, R G; Peigh, P S; Cohn, L H; Lee, R T
1991-10-01
Treatment of patients with aortic regurgitation with vasodilators reduces regurgitant volume, ventricular dilation and left ventricular mass. Although these effects are presumably due to afterload reduction, it is also possible that the aortic regurgitant orifice area is not constant. To test the latter hypothesis, aortic regurgitation was created in 10 open chest sheep by partial resection of the noncoronary leaflet under direct visualization. Regurgitant flow was measured with an aortic supravalvular electromagnetic probe; aortic and left ventricular pressures were measured with catheter-tipped micromanometer pressure transducers. The effective regurgitant orifice area was calculated by a modification of the continuity equation in a manner similar to the Gorlin equation. The regurgitant orifice area was measured three times: after aortic regurgitation was created, after mean arterial pressure was increased by 15 to 25 mm Hg with intravenous dopamine and after mean arterial pressure was reduced by 15 to 25 mm Hg with intravenous sodium nitroprusside. Comparison of regurgitant volumes and areas obtained after creation of aortic regurgitation and at the conclusion of the experiment in the absence of dopamine or sodium nitroprusside demonstrated no significant change over time. Dopamine administration was associated with an 86 +/- 81% increase in regurgitant volume (p less than 0.01) and a 38 +/- 44% increase in regurgitant orifice area (p less than 0.01). Sodium nitroprusside administration resulted in a 51 +/- 14% decrease in regurgitant volume (p less than 0.001) and a 28 +/- 21% reduction in regurgitant orifice area (p = 0.007). In this model of acute aortic regurgitation, the effective regurgitant orifice area was altered by increasing or decreasing the aortic transvalvular pressure gradient.(ABSTRACT TRUNCATED AT 250 WORDS)
Shiota, T; Jones, M; Teien, D E; Yamada, I; Passafini, A; Ge, S; Sahn, D J
1995-08-01
The aim of the present study was to investigate dynamic changes in the mitral regurgitant orifice using electromagnetic flow probes and flowmeters and the color Doppler flow convergence method. Methods for determining mitral regurgitant orifice areas have been described using flow convergence imaging with a hemispheric isovelocity surface assumption. However, the shape of flow convergence isovelocity surfaces depends on many factors that change during regurgitation. In seven sheep with surgically created mitral regurgitation, 18 hemodynamic states were studied. The aliasing distances of flow convergence were measured at 10 sequential points using two ranges of aliasing velocities (0.20 to 0.32 and 0.56 to 0.72 m/s), and instantaneous flow rates were calculated using the hemispheric assumption. Instantaneous regurgitant areas were determined from the regurgitant flow rates obtained from both electromagnetic flowmeters and flow convergence divided by the corresponding continuous wave velocities. The regurgitant orifice sizes obtained using the electromagnetic flow method usually increased to maximal size in early to midsystole and then decreased in late systole. Patterns of dynamic changes in orifice area obtained by flow convergence were not the same as those delineated by the electromagnetic flow method. Time-averaged regurgitant orifice areas obtained by flow convergence using lower aliasing velocities overestimated the areas obtained by the electromagnetic flow method ([mean +/- SD] 0.27 +/- 0.14 vs. 0.12 +/- 0.06 cm2, p < 0.001), whereas flow convergence, using higher aliasing velocities, estimated the reference areas more reliably (0.15 +/- 0.06 cm2). The electromagnetic flow method studies uniformly demonstrated dynamic change in mitral regurgitant orifice area and suggested limitations of the flow convergence method.
NASA Technical Reports Server (NTRS)
Damerow, W. P.; Murtaugh, J. P.; Burggraf, F.
1972-01-01
The flow characteristics of turbine airfoil cooling system components were experimentally investigated. Flow models representative of leading edge impingement, impingement with crossflow (midchord cooling), pin fins, feeder supply tube, and a composite model of a complete airfoil flow system were tested. Test conditions were set by varying pressure level to cover the Mach number and Reynolds number range of interest in advanced turbine applications. Selected geometrical variations were studied on each component model to determine these effects. Results of these tests were correlated and compared with data available in the literature. Orifice flow was correlated in terms of discharge coefficients. For the leading edge model this was found to be a weak function of hole Mach number and orifice-to-impinged wall spacing. In the impingement with crossflow tests, the discharge coefficient was found to be constant and thus independent of orifice Mach number, Reynolds number, crossflow rate, and impingement geometry. Crossflow channel pressure drop showed reasonable agreement with a simple one-dimensional momentum balance. Feeder tube orifice discharge coefficients correlated as a function of orifice Mach number and the ratio of the orifice-to-approach velocity heads. Pin fin data was correlated in terms of equivalent friction factor, which was found to be a function of Reynolds number and pin spacing but independent of pin height in the range tested.
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.; Larson, Terry J.
1990-01-01
A nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was installed and flight-tested on the F-18 high alpha research flight vehicle. The system is a matrix of 25 pressure orifices in concentric circles on the nose of the vehicle. The orifices determine angles of attack and sideslip, Mach number, and pressure altitude. Pressure was transmitted from the orifices to an electronically scanned pressure module by lines of pneumatic tubing. The HI-FADS system was calibrated and demonstrated using dutch roll flight maneuvers covering large Mach, angle-of-attack, and sideslip ranges. Reference airdata for system calibration were generated by a minimum variance estimation technique blending measurements from two wingtip airdata booms with inertial velocities, aircraft angular rates and attitudes, precision radar tracking, and meteorological analyses. The pressure orifice calibration was based on identifying empirical adjustments to modified Newtonian flow on a hemisphere. Calibration results are presented. Flight test results used all 25 orifices or used a subset of 9 orifices. Under moderate maneuvering conditions, the HI-FADS system gave excellent results over the entire subsonic Mach number range up to 55 deg angle of attack. The internal pneumatic frequency response of the system is accurate to beyond 10 Hz. Aerodynamic lags in the aircraft flow field caused some performance degradation during heavy maneuvering.
NASA Technical Reports Server (NTRS)
Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)
2003-01-01
A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.
Plasma characteristics in the discharge region of a 20 A emission current hollow cathode
NASA Astrophysics Data System (ADS)
Mingming, SUN; Tianping, ZHANG; Xiaodong, WEN; Weilong, GUO; Jiayao, SONG
2018-02-01
Numerical calculation and fluid simulation methods were used to obtain the plasma characteristics in the discharge region of the LIPS-300 ion thruster’s 20 A emission current hollow cathode and to verify the structural design of the emitter. The results of the two methods indicated that the highest plasma density and electron temperature, which improved significantly in the orifice region, were located in the discharge region of the hollow cathode. The magnitude of plasma density was about 1021 m-3 in the emitter and orifice regions, as obtained by numerical calculations, but decreased exponentially in the plume region with the distance from the orifice exit. Meanwhile, compared to the emitter region, the electron temperature and current improved by about 36% in the orifice region. The hollow cathode performance test results were in good agreement with the numerical calculation results, which proved that that the structural design of the emitter and the orifice met the requirements of a 20 A emission current. The numerical calculation method can be used to estimate plasma characteristics in the preliminary design stage of hollow cathodes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cox, E.F.
1949-03-28
An orifice-manifold systems were used for baro-switch pressure measurements during a bomb drop. The purpose of this report was to show that definite relations exist between manifold volume and correct orifice diameter.
Low-Current, Xenon Orificed Hollow Cathode Performance for In-Space Applications
NASA Technical Reports Server (NTRS)
Domonkos, Matthew T.; Patterson, Michael J.; Gallimore, Alec D.
2002-01-01
An experimental investigation of the operating characteristics of 3.2-mm diameter orificed hollow cathodes was conducted to examine low current and low flow rate operation. Cathode power was minimized with an orifice aspect ratio of approximately one and the use of an enclosed keeper. Cathode flow rate requirements were proportional to orifice diameter and the inverse of the orifice length. The minimum power consumption in diode mode was 10-W, and the minimum mass flow rate required for spot-mode emission was approximately 0.08-mg/s. Cathode temperature profiles were obtained using an imaging radiometer and conduction was found to be the dominant heat transfer mechanism from the cathode tube. Orifice plate temperatures were found to be weakly dependent upon the flow rate and strongly dependent upon the current.
ETF Facility evaporator skid orifice sizing design analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
ELLINGSON, S.D.
1999-08-31
This document releases and records the design analysis for sizing the Orifice plate being installed on the Effluent Treatment Facility (ETF) evaporator skid per Engineering Change Notice (ECN) 651583.
Double-orifice mitral valve associated with bicuspid aortic valve.
Khani, Mohammad; Rohani, Atoosheh
2017-06-01
Double-orifice mitral valve is a rare congenital anomaly that usually does not cause a significant hemodynamic effect. Double-orifice mitral valve and a bicuspid aortic valve were detected in a 54-year-old lady who presented with dyspnea on exertion for one year. This is a rare association. Three-dimensional echocardiography is helpful to determine the type of malformation. The patient had no significant mitral regurgitation or stenosis, but demonstrated moderate aortic stenosis. She is undergoing periodic monitoring.
Chevron facility focused on commercial orifice-meter research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, E.H.; Ferguson, K.R.
1987-07-27
Research to determine the accuracy of commercial orifice meters for custody-transfer measurement has indicated that high-volume gas meters can be flow-proven while in such service. The research further yielded more accurate orifice-meter discharge coefficient equations (at Reynolds numbers greater than 4,000,000) than current equations of the International Standards Organization (ISO) and the American Petroleum Institute (API). These are partial findings of a major study conducted by Chevron Oil Field Research Co. at its Venice, La., calibration facility.
1976-03-01
those of reference 14, for the case shown. As can be seen agreement is fair. In reference 12, which developed the basic inner flow field program used...through which the nozzle protruded, the other end being open to the outside. Orifice plates of specific diameters were constructed and mated to cylinders...corresponding to the orifice diameters. The purpose of the orifice was to seal the open end such that entrained air could only enter through the porous
Performance Evaluation of Steam Traps and Orifice Plates.
1980-10-01
ADlAO9dl 229 JOHNS - MANVILLE SALES CORP DENVER CO RESEARCH AND DEV-’ETC F/S 13/1 PERFOR1ANCE EVALUATION OF STEAM TRAPS AND ORIFICE PLATES.(U)/ OCT 80...AGENCY t REPORT FESA-TS-2085 41! PERFORMANCE EVALUATION OF STEAM TRAPS AND ORIFICE PLATES P. B. SHEPHERD JOHNS - MANVILLE SALES CORPORATION w RESEARCH...PERFORMING ORGANIZATION NAME ANED ADDPESS!_ i lFioC’iA.TCr ’.ETPlJ A~ Johns - Manville Sales Corporation &00* 0 - Research & Development Center qOll Ken
A pulse-tube refrigerator using variable-resistance orifice
NASA Astrophysics Data System (ADS)
Huang, B. J.; Sun, B. W.
2003-01-01
In the present study, we propose a new design of orifice pulse-tube refrigerator (VROPT) using a variable-resistance valve to replace the conventional orifice. The variable-resistance orifice (VRO) is basically a high-speed solenoidal valve similar to the fuel jet device widely used in automobile engines. By changing the frequency and periods of ON and OFF of the valve through an electronic device, we can change the flow resistance of the VRO. This thus provides a possibility for an OPT to be controlled on-line during operation. From the results obtained in the present study, we have shown that VROPT is able to achieve on-line control by regulating the duty cycle d or frequency fv of the VRO. We also show that VROPT will not loss its thermal performance as compared to conventional OPT.
Orifice-induced pressure error studies in Langley 7- by 10-foot high-speed tunnel
NASA Technical Reports Server (NTRS)
Plentovich, E. B.; Gloss, B. B.
1986-01-01
For some time it has been known that the presence of a static pressure measuring hole will disturb the local flow field in such a way that the sensed static pressure will be in error. The results of previous studies aimed at studying the error induced by the pressure orifice were for relatively low Reynolds number flows. Because of the advent of high Reynolds number transonic wind tunnels, a study was undertaken to assess the magnitude of this error at high Reynolds numbers than previously published and to study a possible method of eliminating this pressure error. This study was conducted in the Langley 7- by 10-Foot High-Speed Tunnel on a flat plate. The model was tested at Mach numbers from 0.40 to 0.72 and at Reynolds numbers from 7.7 x 1,000,000 to 11 x 1,000,000 per meter (2.3 x 1,000,000 to 3.4 x 1,000,000 per foot), respectively. The results indicated that as orifice size increased, the pressure error also increased but that a porous metal (sintered metal) plug inserted in an orifice could greatly reduce the pressure error induced by the orifice.
Guerra, V G; Gonçalves, J A S; Coury, J R
2009-01-15
Venturi scrubbers are widely utilized in gas cleaning. The cleansing elements in these scrubbers are droplets formed from the atomization of a liquid into a dust-laden gas. In industrial scrubbers, this liquid is injected through several orifices so that the cloud of droplets can be evenly distributed throughout the duct. The interaction between droplets when injected through many orifices, where opposite clouds of atomized liquid can reach each other, is to be expected. This work presents experimental measurements of droplet size measured in situ and the evidence of cloud interaction within a Venturi scrubber operating with multi-orifice jet injection. The influence of gas velocity, liquid flow rate and droplet size variation in the axial position after the point of the injection of the liquid were also evaluated for the different injection configurations. The experimental results showed that an increase in the liquid flow rate generated greater interaction between jets. The number of orifices had a significant influence on droplet size. In general, the increase in the velocity of the liquid jet and in the gas velocity favored the atomization process by reducing the size of the droplets.
Angled injection: Hybrid fluid film bearings for cryogenic applications
NASA Technical Reports Server (NTRS)
SanAndres, Luis
1995-01-01
A computational bulk-flow analysis for prediction of the force coefficients of hybrid fluid film bearings with angled orifice injection is presented. Past measurements on water-lubricated hybrid bearings with angle orifice injection have demonstrated improved rotordynamic performance with virtual elimination of cross-coupled stiffness coefficients and nul or negative whirl frequency ratios. A simple analysis reveals that the fluid momentum exchange at the orifice discharge produces a pressure rise in the recess which retards the shear flow induced by journal rotation, and consequently, reduces cross-coupling forces. The predictions from the model correlate well with experimental measurements from a radial and 45 deg angled orifice injection, five recess water hybrid bearings (C = 125 microns) operating at 10.2, 17.4, and 24.6 krpm and with nominal supply pressures equal to 4, 5.5, and 7 MPa. An application example for a liquid oxygen six recess/pad hybrid journal bearing shows the advantages of tangential orifice injection on the rotordynamic force coefficients and stability indicator for forward whirl motions and without performance degradation on direct stiffness and damping coefficients. The computer program generated, 'hydrojet,' extends and complements previously developed codes.
NASA Astrophysics Data System (ADS)
de Domenico, Francesca; Rolland, Erwan; Hochgreb, Simone
2017-11-01
Pressure fluctuations in combustors arise either directly from the heat release rate perturbations of the flame (direct noise), or indirectly from the acceleration of entropy, vorticity or compositional perturbations through nozzles or turbine guide vanes (indirect noise). In this work, the second mechanism is experimentally investigated in a simplified rig. Synthetic entropy spots are generated via Joule effect or helium injection and then accelerated via orifice plates of different area contraction and thickness. The objective of the study is to parametrically analyse the entropy-to-sound conversion in non isentropic contractions (e.g. with pressure losses), represented by the orifice plates. Acoustic measurements are performed to reconstruct the acoustic and entropic transfer functions of the orifices and compare experimental data with analytical predictions, to investigate the effect of orifice thickness and area ratio on the transfer functions. PIV measurements are performed to study the stretching and dispersion of the entropy waves due to mean flow effects. Secondly, PIV images taken in the jet exiting downstream of the orifices are used to investigate the coupling of the acoustic and entropy fields with the hydrodynamic field. EPRSC, Qualcomm.
Fortuna, A O; Gurd, J R
1999-01-01
During certain medical procedures, it is important to continuously measure the respiratory flow of a patient, as lack of proper ventilation can cause brain damage and ultimately death. The monitoring of the ventilatory condition of a patient is usually performed with the aid of flowmeters. However, water and other secretions present in the expired air can build up and ultimately block a traditional, restriction-based flowmeter; by using an orifice plate flowmeter, such blockages are minimized. This paper describes the design of an orifice plate flowmetering system including, especially, a description of the numerical and computational techniques adopted in order to simulate human respiratory and sinusoidal air flow across various possible designs for the orifice plate flowmeter device. Parallel computation and multigrid techniques were employed in order to reduce execution time. The simulated orifice plate was later built and tested under unsteady sinusoidal flows. Experimental tests show reasonable agreement with the numerical simulation, thereby reinforcing the general hypothesis that computational exploration of the design space is sufficiently accurate to allow designers of such systems to use this in preference to the more traditional, mechanical prototyping techniques.
49 CFR 230.71 - Orifice testing of compressors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Compressor size Single strokes per minute Diameter of orifice(in inches) Air pressure maintained(in pounds... feet the speed of compressor may be increased 5 single strokes per minute for each 1,000 feet increase...
49 CFR 230.71 - Orifice testing of compressors.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Compressor size Single strokes per minute Diameter of orifice(in inches) Air pressure maintained(in pounds... feet the speed of compressor may be increased 5 single strokes per minute for each 1,000 feet increase...
49 CFR 230.71 - Orifice testing of compressors.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Compressor size Single strokes per minute Diameter of orifice(in inches) Air pressure maintained(in pounds... feet the speed of compressor may be increased 5 single strokes per minute for each 1,000 feet increase...
49 CFR 230.71 - Orifice testing of compressors.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Compressor size Single strokes per minute Diameter of orifice(in inches) Air pressure maintained(in pounds... feet the speed of compressor may be increased 5 single strokes per minute for each 1,000 feet increase...
49 CFR 230.71 - Orifice testing of compressors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Compressor size Single strokes per minute Diameter of orifice(in inches) Air pressure maintained(in pounds... feet the speed of compressor may be increased 5 single strokes per minute for each 1,000 feet increase...
Simple, Internally Adjustable Valve
NASA Technical Reports Server (NTRS)
Burley, Richard K.
1990-01-01
Valve containing simple in-line, adjustable, flow-control orifice made from ordinary plumbing fitting and two allen setscrews. Construction of valve requires only simple drilling, tapping, and grinding. Orifice installed in existing fitting, avoiding changes in rest of plumbing.
Sealpot and method for controlling a solids flow rate therethrough
Chiu, John H.; Teigen, Bard C.
2015-10-20
A sealpot for a combustion power plant includes a downcomer standpipe which receives solids of the combustion power plant, a bed including a first end and a second opposite end, the first end connected to the downcomer standpipe, a discharge standpipe disposed at the second opposite end of the bed, and an orifice plate disposed between the bed and the discharge standpipe separating the discharge standpipe from the bed. The orifice plate includes apertures disposed at a height above the bed which allow transport of fluidized solids and gas through the orifice plate.
Effect of orifice length-diameter ratio on the coefficient of discharge of fuel-injection nozzles
NASA Technical Reports Server (NTRS)
Gelalles, A G; March, E T
1931-01-01
The variation of the coefficient of discharge with the length-diameter ratio of the orifice was determined for nozzles having single orifice 0.008 and 0.020 inch in diameter. Ratios from 0.5 to 10 were investigated at injection pressures from 500 to 5,000 pounds per square inch. The tests showed that, within the error of the observation, the coefficients were the same whether the nozzles were assembled at the end of a constant tube or in an automatic injection valve having a plain stem.
The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.
Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria
2016-01-01
A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of <1. 0m2, and 1.5 mm for a BSA of >1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency or stenosis. Reoperations on three patients (mean age 42.5 ± 8.7 years) were indicated for aortic valve replacement at 14 months postoperatively (n = 1) and for assist device implantation (n = 2) who eventually underwent heart transplant at 18 and 20 months after TV repair, respectively. The cumulative 12-year survival rate was 86.9%. This double-orifice technique is technically a straightforward repair to abolish TV incompetence with highly satisfactory results, particularly in patients with severe annular dilatation or with leaflet and chordal tethering. In the present series, the technique provided no pitfalls (if the location of the conduction system was borne in mind), requiring only a gentle placement of sutures. It also led to no residual regurgitation or reoperation during the follow up period.
Minami, Yoshiyasu; Wang, Zhao; Aguirre, Aaron D; Lee, Stephen; Uemura, Shiro; Soeda, Tsunenari; Vergallo, Rocco; Raffel, Owen C; Barlis, Peter; Itoh, Tomonori; Lee, Hang; Fujimoto, James; Jang, Ik-Kyung
2016-01-01
Methods for intravascular assessment of the side-branch (SB) orifice after stenting are not readily available. The aim of this study was to assess the utility of an en-face projection processing for optical coherence tomography (OCT) images for SB evaluation. Measurements of the SB orifice obtained using en-face OCT images were validated using a phantom model. Linear regression modeling was applied to estimated area measurements made on the en-face images. The SB orifice was then analyzed in 88 patients with bifurcation lesions treated with either Xience V (everolimus-eluting stent) or Resolute Integrity [zotarolimus-eluting stent (ZES)]. The SB orifice area (A) and the area obstructed by struts (B) were calculated, and the %open area was evaluated as (A-B)/A*100. Linear regression modeling demonstrated that the observed departures of the intercept and slope were not significantly different from 0 (-0.12 ± 0.22, P=0.59) and 1 (1.01 ± 0.06, R(2)=0.88, P=0.87), respectively. In cases without SB dilatation, the %open area was significantly larger in the everolimus-eluting stent group (n=25) than in the ZES group [n=32; 89.2% (83.7-91.3) vs. 84.3% (78.9-87.8), P=0.04]. A significant difference in %open area between cases with and those without SB dilatation was demonstrated in the ZES group [91.4% (86.1-94.0) vs. 84.3% (78.9-87.8), P=0.04]. The accuracy of SB orifice measurement on an en-face OCT image was validated using a phantom model. This novel approach enables quantitative evaluation of the differences in SB orifice area free from struts among different stent types and different treatment strategies in vivo.
Ghulman, Motaz Ahmad; Gomaa, Madiha
2012-01-01
Aim. To investigate the effect of orifice cavity depth on the sealing ability of Fusio, Fuji II, Fuji IX, and MTA“G”. Materials and Methods. Ninety-two canals in extracted mandibular premolars were prepared, obturated, and randomly grouped into 4 groups. Each group was subgrouped for a 2 mm and 3 mm orifice cavity depth (n = 10). The remaining roots were divided to serve as positive and negative controls (n = 6). Cavities of the 4 experimental groups were filled with the respective materials and subjected to methylene blue dye leakage. Linear leakage was measured in mm using a stereomicroscope. Statistical Analysis. Kruskall-Wallis test was used at P < 0.05, and t-test was done to compare 2 mm and 3 mm. Results. All tested materials leaked to various degrees. Significantly higher leakage score was found for Fuji IX, Fusio, Fuji II, and MTA “G” in a descending order, when the materials were placed at 3 mm depths. A significant difference was found in the leakage score between the 2 mm and 3 mm depths in all tested materials with the 3 mm depth showing a greater leakage score in all tested materials. Exception was in MTA “G” at 2 mm and 3 mm depths (0.551 mm ± 0.004 mm and 0.308 mm ± 0.08 mm, resp.). Conclusion. The null hypothesis should be partially rejected. Fusio and MTA “G” were affected by orifice cavity depth with regard to their sealing ability. MTA “G” had the least leakage when placed at 2 or 3 mm depths, and Fusio is the next when placed at 2 mm depth. Two millimeters orifice cavity depth is suitable for most adhesive orifice barrier materials. PMID:22675356
Spagnuolo, Gianrico; Ametrano, Gianluca; D'Antò, Vincenzo; Formisano, Anna; Simeone, Michele; Riccitiello, Francesco; Amato, Massimo; Rengo, Sandro
2012-01-01
Aim of the study was to determined by microcomputed tomography (µCT) the horizontal distance between the main (MB1) and the second mesiobuccal canal (MB2) orifices, the vertical distance between the MB1 and MB2 orifices planes, and the distance between the anatomic apex and major apical foramen (AF). Furthermore, we characterized the entire internal and external anatomy of the MB, distalbuccal (DB) and palatal (P) maxillary first molars roots. Twenty-two intact extracted first maxillary molars were scanned by X-ray computed transaxial µCT and then 2D and 3D images were processed and analyzed. The results showed that 77.27% of the mesiobuccal (MB) roots presented a second MB canal, and 29.41% of the MB2 were independent from the MB1 canals. In 15 teeth, there were three root canal orifices on the chamber floor, and 10 of these teeth presented MB2 canals. The mean vertical distance between the MB1 and MB2 planes was 1.68 ± 0.83 mm. Seven teeth had four orifices. The mean horizontal interorificial distance between the MB1 and MB2 orifices was 1.21 ± 0.5 mm. Accessory canals were observed in 33.33% of the roots, loops in 6.06%, while isthmuses were found in 15 of the 22 MB roots. Of the total roots, 74.24% presented one foramen, while all of the roots showed a major apical foramen that was not coincident with the anatomic apex. Our µCT analysis provided interesting features on the horizontal and vertical distance between the MB1 and MB2 orifices and on the distance of AF and anatomic apex. These results have an important clinical value because might support the endodontist in the recruitment, negotiation and obturation of maxillary first molar canal system.
Spagnuolo, Gianrico; Ametrano, Gianluca; D’Antò, Vincenzo; Formisano, Anna; Simeone, Michele; Riccitiello, Francesco; Amato, Massimo; Rengo, Sandro
2012-01-01
Objective: Aim of the study was to determined by microcomputed tomography (µCT) the horizontal distance between the main (MB1) and the second mesiobuccal canal (MB2) orifices, the vertical distance between the MB1 and MB2 orifices planes, and the distance between the anatomic apex and major apical foramen (AF). Furthermore, we characterized the entire internal and external anatomy of the MB, distalbuccal (DB) and palatal (P) maxillary first molars roots. Materials and Methods: Twenty-two intact extracted first maxillary molars were scanned by X-ray computed transaxial µCT and then 2D and 3D images were processed and analyzed. Results: The results showed that 77.27% of the mesiobuccal (MB) roots presented a second MB canal, and 29.41% of the MB2 were independent from the MB1 canals. In 15 teeth, there were three root canal orifices on the chamber floor, and 10 of these teeth presented MB2 canals. The mean vertical distance between the MB1 and MB2 planes was 1.68 ± 0.83 mm. Seven teeth had four orifices. The mean horizontal interorificial distance between the MB1 and MB2 orifices was 1.21 ± 0.5 mm. Accessory canals were observed in 33.33% of the roots, loops in 6.06%, while isthmuses were found in 15 of the 22 MB roots. Of the total roots, 74.24% presented one foramen, while all of the roots showed a major apical foramen that was not coincident with the anatomic apex. Conclusions: Our µCT analysis provided interesting features on the horizontal and vertical distance between the MB1 and MB2 orifices and on the distance of AF and anatomic apex. Clinical Relevance: These results have an important clinical value because might support the endodontist in the recruitment, negotiation and obturation of maxillary first molar canal system. PMID:22905069
Vacuum chamber with a supersonic flow aerodynamic window
Hanson, Clark L.
1982-01-01
A supersonic flow aerodynamic window, whereby a steam ejector situated in a primary chamber at vacuum exhausts superheated steam toward an orifice to a region of higher pressure, creating a barrier to the gas in the region of higher pressure which attempts to enter through the orifice. In a mixing chamber outside and in fluid communication with the primary chamber, superheated steam and gas are combined into a mixture which then enters the primary chamber through the orifice. At the point of impact of the ejector/superheated steam and the incoming gas/superheated steam mixture, a barrier is created to the gas attempting to enter the ejector chamber. This barrier, coupled with suitable vacuum pumping means and cooling means, serves to keep the steam ejector and primary chamber at a negative pressure, even though the primary chamber has an orifice to a region of higher pressure.
Methods and systems to enhance flame holding in a gas turbine engine
Zuo, Baifang [Simpsonville, SC; Lacy, Benjamin Paul [Greer, SC; Stevenson, Christian Xavier [Inman, SC
2012-01-31
A fuel nozzle including a swirler assembly that includes a shroud, a hub, and a plurality of vanes extending between the shroud and the hub. Each vane includes a pressure sidewall and an opposite suction sidewall coupled to the pressure sidewall at a leading edge and at a trailing edge. At least one suction side fuel injection orifice is formed adjacent to the leading edge and extends from a first fuel supply passage to the suction sidewall. A fuel injection angle is oriented with respect to the suction sidewall. The suction side fuel injection orifice is configured to discharge fuel outward from the suction sidewall. At least one pressure side fuel injection orifice extends from a second fuel supply passage to the pressure sidewall and is substantially parallel to the trailing edge. The pressure side fuel injection orifice is configured to discharge fuel tangentially from the trailing edge.
Wang, Wen-Min; Qiu, Wei-Feng; Qian, Chong
2010-07-01
To explore the feasibility of urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate in the treatment of hypospadias. Forty-eight patients with hypospadias (18 of the coronal type, 21 the penile type, 8 the penoscrotal type and 1 the perineal type) underwent urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate. The surgical effects were observed by following up the patients for 3-27 months. One-stage surgical success was achieved in 44 of the cases, with satisfactory functional and cosmetic results but no complications. Two cases developed urinary fistula and another 2 urethral stricture, but all cured by the second surgery. Urethroplasty with transection of the urethral orifice and preservation and lengthening of the urethral plate is a simple, safe and effective surgical procedure for the treatment of hypospadias.
Vacuum chamber with a supersonic-flow aerodynamic window
Hanson, C.L.
1980-10-14
A supersonic flow aerodynamic window is disclosed whereby a steam ejector situated in a primary chamber at vacuum exhausts superheated steam toward an orifice to a region of higher pressure, creating a barrier to the gas in the region of higher pressure which attempts to enter through the orifice. In a mixing chamber outside and in fluid communication with the primary chamber, superheated steam and gas are combined into a mixture which then enters the primary chamber through the orifice. At the point of impact of the ejector/superheated steam and the incoming gas/superheated steam mixture, a barrier is created to the gas attempting to enter the ejector chamber. This barrier, coupled with suitable vacuum pumping means and cooling means, serves to keep the steam ejector and primary chamber at a negative pressure, even though the primary chamber has an orifice to a region of higher pressure.
Li, Xiaokui; Wanitkun, Suthep; Li, Xiang-Ning; Hashimoto, Ikuo; Mori, Yoshiki; Rusk, Rosemary A; Hicks, Shannon E; Sahn, David J
2002-10-01
Our study was intended to test the accuracy of a 3-dimensional (3D) digital color Doppler flow convergence (FC) method for assessing the effective orifice area (EOA) in a new dynamic orifice model mimicking a variety of mitral regurgitation. FC surface area methods for detecting EOA have been reported to be useful for quantifying the severity of valvular regurgitation. With our new 3D digital direct FC method, all raw velocity data are available and variable Nyquist limits can be selected for computation of direct FC surface area for computing instantaneous flow rate and temporal change of EOA. A 7.0-MHz multiplane transesophageal probe from an ultrasound system (ATL HDI 5000) was linked and controlled by a computer workstation to provide 3D images. Three differently shaped latex orifices (zigzag, arc, and straight slit, each with cutting-edge length of 1 cm) were used to mimic the dynamic orifice of mitral regurgitation. 3D FC surface computation was performed on parallel slices through the 3D data set at aliasing velocities (14-48 cm/s) selected to maximize the regularity and minimize lateral dropout of the visualized 3D FC at 5 points per cardiac cycle. Using continuous wave velocity for each, 3D-calculated EOA was compared with EOA determined by using continuous wave Doppler and the flow rate from a reference ultrasonic flow meter. Simultaneous digital video images were also recorded to define the actual orifice size for 9 stroke volumes (15-55 mL/beat with maximum flow rates 45-182 mL/s). Over the 9 pulsatile flow states and 3 orifices, 3D FC EOAs (0.05-0.63 cm(2)) from different phases of the cardiac cycle in each pump setting correlated well with reference EOA (r = 0.89-0.92, SEE = 0.027-0.055cm(2)) and they also correlated well with digital video images of the actual orifice peak (r = 0.97-0.98, SEE = 0.016-0.019 cm(2)), although they were consistently smaller, as expected by the contraction coefficient. The digital 3D FC method can accurately predict flow rate, and, thus, EOA (in conjunction with continuous wave Doppler), because it allows direct FC surface measurement despite temporal variability of FC shape.
Glacier surge mechanism based on linked cavity configuration of the basal water conduit system
NASA Astrophysics Data System (ADS)
Kamb, Barclay
1987-08-01
Based on observations of the 1982-1983 surge of Variegated Glacier, Alaska, a model of the surge mechanism is developed in terms of a transition from the normal tunnel configuration of the basal water conduit system to a linked cavity configuration that tends to restrict the flow of water, resulting in increased basal water pressures that cause rapid basal sliding. The linked cavity system consists of basal cavities formed by ice-bedrock separation (cavitation), ˜1 m high and ˜10 m in horizontal dimensions, widely scattered over the glacier bed, and hydraulically linked by narrow connections where separation is minimal (separation gap ≲ 0.1 m). The narrow connections, called orifices, control the water flow through the conduit system; by throttling the flow through the large cavities, the orifices keep the water flux transmitted by the basal water system at normal levels even though the total cavity cross-sectional area (˜200 m2) is much larger than that of a tunnel system (˜10 m2). A physical model of the linked cavity system is formulated in terms of the dimensions of the "typical" cavity and orifice and the numbers of these across the glacier width. The model concentrates on the detailed configuration of the typical orifice and its response to basal water pressure and basal sliding, which determines the water flux carried by the system under given conditions. Configurations are worked out for two idealized orifice types, step orifices that form in the lee of downglacier-facing bedrock steps, and wave orifices that form on the lee slopes of quasisinusoidal bedrock waves and are similar to transverse "N channels." The orifice configurations are obtained from the results of solutions of the basal-sliding-with-separation problem for an ice mass constituting of linear half-space of linear rheology, with nonlinearity introduced by making the viscosity stress-dependent on an intuitive basis. Modification of the orifice shapes by melting of the ice roof due to viscous heat dissipation in the flow of water through the orifices is treated in detail under the assumption of local heat transfer, which guarantees that the heating effects are not underestimated. This treatment brings to light a melting-stability parameter Ξ that provides a measure of the influence of viscous heating on orifice cavitation, similar but distinct for step and wave orifices. Orifice shapes and the amounts of roof meltback are determined by Ξ. When Ξ ≳ 1, so that the system is "viscous-heating-dominated," the orifices are unstable against rapid growth in response to a modest increase in water pressure or in orifice size over their steady state values. This growth instability is somewhat similar to the jökulhlaup-type instability of tunnels, which are likewise heating-dominated. When Ξ ≲ 1, the orifices are stable against perturbations of modest to even large size. Stabilization is promoted by high sliding velocity ν, expressed in terms of a ν-½ and ν-1 dependence of Ξ for step and wave cavities. The relationships between basal water pressure and water flux transmitted by linked cavity models of step and wave orifice type are calculated for an empirical relation between water pressure and sliding velocity and for a particular, reasonable choice of system parameters. In all cases the flux is an increasing function of the water pressure, in contrast to the inverse flux-versus-pressure relation for tunnels. In consequence, a linked cavity system can exist stably as a system of many interconnected conduits distributed across the glacier bed, in contrast to a tunnel system, which must condense to one or at most a few main tunnels. The linked cavity model gives basal water pressures much higher than the tunnel model at water fluxes ≳1 m3/s if the bed roughness features that generate the orifices have step heights or wave amplitudes less than about 0.1 m. The calculated basal water pressure of the particular linked cavity models evaluated is about 2 to 5 bars below ice overburden pressure for water fluxes in the range from about 2 to 20 m3/s, which matches reasonably the observed conditions in Variegated Glacier in surge; in contrast, the calculated water pressure for a single-tunnel model is about 14 to 17 bars below overburden over the same flux range. The contrast in water pressures for the two types of basal conduit system furnishes the basis for a surge mechanism involving transition from a tunnel system at low pressure to a linked cavity system at high pressure. The parameter Ξ is about 0.2 for the linked cavity models evaluated, meaning that they are stable but that a modest change in system parameters could produce instability. Unstable orifice growth results in the generation of tunnel segments, which may connect up in a cooperative fashion, leading to conversion of the linked cavity system to a tunnel system, with large decrease in water pressure and sliding velocity. This is what probably happens in surge termination. Glaciers for which Ξ ≲ 1 can go into surge, while those for which Ξ ≳ 1 cannot. Because Ξ varies as α3/2 (where α is surface slope), low values of Ξ are more probable for glaciers of low slope, and because slope correlates inversely with glacier length in general, the model predicts a direct correlation between glacier length and probability of surging; such a correlation is observed (Clarke et al., 1986). Because Ξ varies inversely with the basal shear stress τ, the increase of τ that takes place in the reservoir area in the buildup between surges causes a decrease in Ξ there, which, by reducing Ξ below the critical value ˜1, can allow surge initiation and the start of a new surge cycle. Transition to a linked cavity system without tunnels should occur spontaneously at low enough water flux, in agreement with observed surge initiation in winter.
TWO-PHASE FLOW OF TWO HFC REFRIGERANT MIXTURES THROUGH SHORT-TUBE ORIFICES
The report gives results of an experimental investigation to develop an acceptable flow model for short tube orifice expansion devices used in heat pumps. The refrigerants investigated were two hydrofluorocarbon (HFC) mixtures considered hydrochlorofluorocarbon (HCFC)-22 replacem...
Contoured Orifice for Silicon-Ribbon Die
NASA Technical Reports Server (NTRS)
Mackintosh, B. H.
1985-01-01
Die configuration encourages purity and stable growth. Contour of die orifice changes near ribbon edges. As result, silicon ribbon has nearly constant width and little carbon contamination. Die part of furnace being developed to produce high-quality, low-cost material for solar cells.
NASA Technical Reports Server (NTRS)
Swaim, Benji D.
1989-01-01
Modified orifice for variable-polarity plasma-arc welding directs welding plume so it creates clean, even welds on both Inconel(R) and aluminum alloys. Includes eight holes to relieve back pressure in plasma. Quality of welds on ferrous and nonferrous alloys improved as result.
Thin film coating process using an inductively coupled plasma
Kniseley, Richard N.; Schmidt, Frederick A.; Merkle, Brian D.
1990-01-30
Thin coatings of normally solid materials are applied to target substrates using an inductively coupled plasma. Particles of the coating material are vaporized by plasma heating, and pass through an orifice to a first vacuum zone in which the particles are accelerated to a velocity greater than Mach 1. The shock wave generated in the first vacuum zone is intercepted by the tip of a skimmer cone that provides a second orifice. The particles pass through the second orifice into a second zone maintained at a higher vacuum and impinge on the target to form the coating. Ultrapure coatings can be formed.
1980-02-01
discharge coefficient of C = 3.4 was used. 0 Orifice flow condition when the reservoir water surface sub- merges the inlet opening. * Broad crested weir flow...2.7 was used. The intake tower will operate as a weir , as a weir and an orifice, or as an orifice and a broad crested weir depending upon the...spillway C prior to overtopping the railroad embankment into the original dam pond. Flow over this low point was calculated as flow over a broad crested weir
NASA Technical Reports Server (NTRS)
Dittrich, R. T.
1972-01-01
Water flow tests with circumferential inlet and outlet manifolds were conducted to determine factors affecting fluid distribution and pressure losses. Various orifice sizes and manifold geometries were tested over a range of flow velocities. With inlet manifolds, flow distribution was related directly to orifice discharge coefficients. A correlation indicated that nonuniform distribution resulted when the velocity head ratio at the orifice was not in the range of constant discharge coefficient. With outlet manifolds, nonuniform flow was related to static pressure variations along the manifold. Outlet manifolds had appreciably greater pressure losses than comparable inlet manifolds.
Experimental Investigation of Cavitation Induced Feedline Instability from an Orifice
NASA Technical Reports Server (NTRS)
Hitt, Matthew A.; Lineberry, David M.; Ahuja, Vineet; Frederick, Robert A,
2012-01-01
This paper details the results of an experimental investigation into the cavitation instabilities created by a circular orifice conducted at the University of Alabama in Huntsville Propulsion Research Center. This experiment was conducted in concert with a computational simulation to serve as a reference point for the simulation. Testing was conducted using liquid nitrogen as a cryogenic propellant simulant. A 1.06 cm diameter thin orifice with a rounded inlet was tested in an approximately 1.25 kg/s flow with inlet pressures ranging from 504.1 kPa to 829.3 kPa. Pressure fluctuations generated by the orifice were measured using a high frequency pressure sensor located 0.64 tube diameters downstream of the orifice. Fast Fourier Transforms were performed on the high frequency data to determine the instability frequency. Shedding resulted in a primary frequency with a cavitation related subharmonic frequency. For this experiment, the cavitation instability ranged from 153 Hz to 275 Hz. Additionally, the strength of the cavitation occur red as a function of cavitation number. At lower cavitation numbers, the strength of the cavitation instability ranged from 2.4 % to 7 % of the inlet pressure. However, at higher cavitation numbers, the strength of the cavitation instability ranged from 0.6 % to 1 % of the inlet pressure.
Cavitation in flow through a micro-orifice inside a silicon microchannel
NASA Astrophysics Data System (ADS)
Mishra, Chandan; Peles, Yoav
2005-01-01
Hydrodynamic cavitation in flows through a micro-orifice entrenched in a microchannel has been detected and experimentally investigated. Microfabrication techniques have been employed to design and develop a microfluidic device containing an 11.5μm wide micro-orifice inside a 100.2μm wide and 101.3μm deep microchannel. The flow of de-ionized water through the micro-orifice reveals the presence of multifarious cavitating flow regimes. This investigation divulges both similarities and differences between cavitation in micro-orifices and cavitation in their macroscale counterparts. The low incipient cavitation number obtained from the current experiments suggests a dominant size scale effect. Choking cavitation is observed to be independent of any pressure or velocity scale effects. However, choking is significantly influenced by the small stream nuclei residence time at such scales. Flow rate choking leads to the establishment of a stationary cavity. Large flow and cavitation hysteresis have been detected at the microscale leading to very high desinent cavitation numbers. The rapid transition from incipient bubbles to choking cavitation and subsequent supercavitation suggests the presence of radically different flow patterns at the microscale. Supercavitation results in a thick cavity, which extends throughout the microchannel, and is encompassed by the liquid. Cavitation at the microscale is expected to considerably influence the design of innovative high-speed microfluidic systems.
The Effects of Air Preheat and Number of Orifices on Flow and Emissions in an RQL Mixing Section
NASA Technical Reports Server (NTRS)
Holdeman, James D.; Chang, Clarence T.
2007-01-01
This study was motivated by a goal to understand the mixing and emissions in the rich-burn/quick-mix/lean-burn (RQL) combustor scheme that has been proposed to minimize the formation of oxides of nitrogen (NOx) in gas turbine combustors. The study reported in this paper was a reacting jet-in-crossflow experiment at atmospheric pressure in a cylindrical duct. The jets were injected from the perimeter of the duct through round-hole orifices into a fuel-rich mainstream flow. The number of orifices investigated in this study gave over- to optimum to underpenetrating jets at a jet-to-mainstream momentum-flux ratio of 57. The size of individual orifices was decreased as their number increased to maintain a constant total area. The jet-to-mainstream mass-flow ratio was held constant at 2.5. The experiments focused on the effects of the number of orifices and inlet air preheat and were conducted in a facility that provided the capability for independent variation of jet and main inlet air preheat temperature. The number of orifices was found to have a significant effect on mixing and the distributions of species, but very little effect on overall NOx emissions, suggesting that an aerodynamically optimum mixer may not minimize NOx emissions. Air preheat was found to have very little effect on mixing and the distributions of major species, but preheat did increase NOx emissions significantly. Although the air jets injected in the quick-mix section of a RQL combustor may comprise over 70% of the total air flow, the overall NOx emission levels were found to be more sensitive to mainstream air preheat than to jet stream air preheat.
On the propagation mechanism of a detonation wave in a round tube with orifice plates
NASA Astrophysics Data System (ADS)
Ciccarelli, G.; Cross, M.
2016-09-01
This study deals with the investigation of the detonation propagation mechanism in a circular tube with orifice plates. Experiments were performed with hydrogen air in a 10-cm-inner-diameter tube with the second half of the tube filled with equally spaced orifice plates. A self-sustained Chapman-Jouguet (CJ) detonation wave was initiated in the smooth first half of the tube and transmitted into the orifice-plate-laden second half of the tube. The details of the propagation were obtained using the soot-foil technique. Two types of foils were used between obstacles, a wall-foil placed on the tube wall, and a flat-foil (sooted on both sides) placed horizontally across the diameter of the tube. When placed after the first orifice plate, the flat foil shows symmetric detonation wave diffraction and failure, while the wall foil shows re-initiation via multiple local hot spots created when the decoupled shock wave interacts with the tube wall. At the end of the tube, where the detonation propagated at an average velocity much lower than the theoretical CJ value, the detonation propagation is much more asymmetric with only a few hot spots on the tube wall leading to local detonation initiation. Consecutive foils also show that the detonation structure changes after each obstacle interaction. For a mixture near the detonation propagation limit, detonation re-initiation occurs at a single wall hot spot producing a patch of small detonation cells. The local overdriven detonation wave is short lived, but is sufficient to keep the global explosion front propagating. Results associated with the effect of orifice plate blockage and spacing on the detonation propagation mechanism are also presented.
Itabashi, Yuji; Utsunomiya, Hiroto; Kubo, Shunsuke; Mizutani, Yukiko; Mihara, Hirotsugu; Murata, Mitsushige; Siegel, Robert J; Kar, Saibal; Fukuda, Keiichi; Shiota, Takahiro
2018-04-01
Postprocedural mitral stenosis (MS) is a main limitation for MitraClip™ (Abbot Vascular, Inc., Santa Clara, CA, USA) procedure. The purpose of this study was to detect the preprocedural predictors of high transmitral pressure gradient (TMPG) after MitraClip™ implantation, which indicated postprocedural mitral stenosis (MS). We studied 79 patients who were implanted with MitraClip™ in our institute. Before the procedure, mitral valve orifice area (MVOA), and anterior-posterior (AP) and medial-lateral (ML) mitral annular diameters were measured at diastole using three-dimensional (3D) transesophageal echocardiography (TEE) data set. After the procedure, the mean TMPG was assessed using continuous-wave (CW) Doppler by periprocedural TEE. Preprocedural MVOA, and AP and ML diameter of left ventricular (LV) inflow orifices were larger in patients with mean TMPG ≤4mmHg than in patients with TMPG >4mmHg after 1-and 2-clip implantation. The large MVOA and ML diameter of LV inflow orifice strongly correlated with the low TMPG after 1- and 2-clip implantation. As a result of the receiver operating characteristic curve analysis, the preprocedural MVOA predicted the low postprocedural TMPG more accurately than the ML diameter of LV inflow orifice after 1-clip implantation either in the degenerative or functional mitral regurgitation (MR) patients. After 2-clip implantation, however, the preprocedural ML diameter of LV inflow orifice predicted it more accurately than the MVOA in the degenerative and functional MR patients. 3D TEE derived MVOA predicts the postprocedural MS after 1-clip implantation, however, preprocedural ML diameter of LV inflow orifice is more useful to predict after 2-clip implantation. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Mixing and NO(x) Emission Calculations of Confined Reacting Jet Flows in a Cylindrical Duct
NASA Technical Reports Server (NTRS)
Holdeman, James D. (Technical Monitor); Oechsle, Victor L.
2003-01-01
Rapid mixing of cold lateral jets with hot cross-stream flows in confined configurations is of practical interest in gas turbine combustors as it strongly affects combustor exit temperature quality, and gaseous emissions in for example rich-lean combustion. It is therefore important to further improve our fundamental understanding of the important processes of dilution jet mixing especially when the injected jet mass flow rate exceeds that of the cross-stream. The results reported in this report describe some of the main flow characteristics which develop in the mixing process in a cylindrical duct. A 3-dimensional tool has been used to predict the mixing flow field characteristics and NOx emission in a quench section of an RQL combustor, Eighteen configurations have been analyzed in a circular geometry in a fully reacting environment simulating the operating condition of an actual RQL gas turbine combustion liner. The evaluation matrix was constructed by varying three parameters: 1) jet-to-mainstream momentum-flux ratio (J), 2) orifice shape or orifice aspect ratio, and 3) slot slant angle. The results indicate that the mixing flow field significantly varies with the value of the jet penetration and subsequently, slanting elongated slots generally improve the mixing uniformity at high J conditions. Round orifices produce more uniform mixing and low NO(x) emissions at low J due to the strong and adequate jet penetration. No significant correlation was found between the NO(x) production rates and the mixing deviation parameters, however, strong correlation was found between NO(x) formation and jet penetration. In the computational results, most of the NO(x) formation occurred behind the orifice starting at the orifice wake region. Additional NO(x) is formed upstream of the orifice in certain configurations with high J conditions due to the upstream recirculation.
Investigation of orifice aeroacoustics by means of multi-port methods
NASA Astrophysics Data System (ADS)
Sack, Stefan; Åbom, Mats
2017-10-01
Comprehensive methods to cascade active multi-ports, e.g., for acoustic network prediction, have until now only been available for plane waves. This paper presents procedures to combine multi-ports with an arbitrary number of considered duct modes. A multi-port method is used to extract complex mode amplitudes from experimental data of single and tandem in-duct orifice plates for Helmholtz numbers up to around 4 and, hence, beyond the cut-on of several higher order modes. The theory of connecting single multi-ports to linear cascades is derived for the passive properties (the scattering of the system) and the active properties (the source cross-spectrum matrix of the system). One scope of this paper is to investigate the influence of the hydrodynamic near field on the accuracy of both the passive and the active predictions in multi-port cascades. The scattering and the source cross-spectrum matrix of tandem orifice configurations is measured for three cases, namely, with a distance between the plates of 10 duct diameter, for which the downstream orifice is outside the jet of the upstream orifice, 4 duct diameter, and 2 duct diameter (both inside the jet). The results are compared with predictions from single orifice measurements. It is shown that the scattering is only sensitive to disturbed inflow in certain frequency ranges where coupling between the flow and sound field exists, whereas the source cross-spectrum matrix is very sensitive to disturbed inflow for all frequencies. An important part of the analysis is based on an eigenvalue analysis of the scattering matrix and the source cross-spectrum matrix to evaluate the potential of sound amplification and dominant source mechanisms.
Yamada, Shigeki; Hashimoto, Kenji; Ogata, Hideki; Watanabe, Yoshihiko; Oshima, Marie; Miyake, Hidenori
2014-02-01
Simple rating scale for calcification in the cervical arteries and the aortic arch on multi-detector computed tomography angiography (MDCTA) was evaluated its reliability and validity. Additionally, we investigated where is the most representative location for evaluating the calcification risk of carotid bifurcation stenosis and atherosclerotic infarction in the overall cervical arteries covering from the aortic arch to the carotid bifurcation. The aortic arch and cervical arteries among 518 patients (292 men, 226 women) were evaluated the extent of calcification using a 4-point grading scale for MDCTA. Reliability, validity and the concomitant risk with vascular stenosis and atherosclerotic infarction were assessed. Calcification was most frequently observed in the aortic arch itself, the orifices from the aortic arch, and the carotid bifurcation. Compared with the bilateral carotid bifurcations, the aortic arch itself had a stronger inter-observer agreement for the calcification score (Fleiss' kappa coefficients; 0.77), but weaker associations with stenosis and atherosclerotic infarction. Calcification at the orifices of the aortic arch branches had a stronger inter-observer agreement (0.74) and enough associations with carotid bifurcation stenosis and intracranial stenosis. In addition, the extensive calcification at the orifices from the aortic arch was significantly associated with atherosclerotic infarction, similar to the calcification at the bilateral carotid bifurcations. The orifices of the aortic arch branches were the novel representative location of the aortic arch and overall cervical arteries for evaluating the calcification extent. Thus, calcification at the aortic arch should be evaluated with focus on the orifices of 3 main branches. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
In-flight investigation of shuttle tile pressure orifice installations
NASA Technical Reports Server (NTRS)
Moes, Timothy R.; Meyer, Robert R., Jr.
1990-01-01
To determine shuttle orbiter wing loads during ascent, wing load instrumentation was added to Columbia (OV-102). This instrumentation included strain gages and pressure orifices on the wing. The loads derived from wing pressure measurements taken during STS 61-C did not agree with those derived from strain gage measurements or with the loads predicted from the aerodynamic database. Anomalies in the surface immediately surrounding the pressure orifices in the thermal protection system (TPS) tiles were one possible cause of errors in the loads derived from wing pressure measurements. These surface anomalies were caused by a ceramic filler material which was installed around the pressure tubing. The filler material allowed slight movement of the TPS tile and pressure tube as the airframe flexed and bent under aerodynamic loads during ascent and descent. Postflight inspection revealed that this filler material had protruded from or receeded beneath the surface, causing the orifice to lose its flushness. Flight tests were conducted at NASA Ames Research Center Dryden Flight Research Facility to determine the effects of any anomaly in surface flushness of the orifice installation on the measured pressures at Mach numbers between 0.6 and 1.4. An F-104 aircraft with a flight test fixture mounted beneath the fuselage was used for these flights. Surface flushness anomalies typical of those on the orbiter after flight (STA 61-C) were tested. Also, cases with excessive protrusion and recession of the filler material were tested. This report shows that the anomalies in STS 61-C orifice installations adversely affected the pressure measurements. But the magnitude of the affect was not great enough to account for the discrepancies with the strain gage measurements and the aerodynamic predictions.
Fluid-solid contact vessel having fluid distributors therein
Jones, Jr., John B.
1980-09-09
Rectangularly-shaped fluid distributors for large diameter, vertical vessels include reinforcers for high heat operation, vertical sides with gas distributing orifices and overhanging, sloped roofs. Devices are provided for cleaning the orifices from a buildup of solid deposits resulting from the reactions in the vessel.
Basic requirements of fuel-injection nozzles for quiescent combustion chambers
NASA Technical Reports Server (NTRS)
Spanogle, J A; Foster, H H
1931-01-01
This report presents test results obtained during an investigation of the performance of a single-cylinder, high-speed, compression-ignition test engine when using multiple-orifice fuel-injection valve nozzles in which the number and the direction of the orifices were varied independently.
Flow Coefficient Behavior for Boundary Layer Bleed Holes and Slots
NASA Technical Reports Server (NTRS)
Willis, B. P.; Davis, D. O.; Hingst, W. R.
1995-01-01
An experimental investigation into the flow coefficient behavior for nine boundary layer bleed orifice configurations is reported. This test was conducted for the purposes of exploring boundary layer control through mass flow removal and does not address issues of stability bleed. Parametric data consist of bleed region flow coefficient as a function of Mach number, bleed plenum pressure, and bleed orifice geometry. Seven multiple hole configurations and two single slot configurations were tested over a supersonic Mach number range of 1.3 to 2.5 (nominal). Advantages gained by using multiple holes in a bleed region instead of a single spanwise slot are discussed and the issue of modeling an entire array of bleed orifices based on the performance of a single orifice is addressed. Preconditioning the flow approaching a 90 degree inclined (normal) hole configuration resulted in a significant improvement in the performance of the configuration. The same preconditioning caused only subtle changes in performance for a 20 degree inclined (slanted) configuration.
A pulse tube cryocooler with a cold reservoir
NASA Astrophysics Data System (ADS)
Zhang, X. B.; Zhang, K. H.; Qiu, L. M.; Gan, Z. H.; Shen, X.; Xiang, S. J.
2013-02-01
Phase difference between pressure wave and mass flow is decisive to the cooling capacity of regenerative cryocoolers. Unlike the direct phase shifting using a piston or displacer in conventional Stirling or GM cryocoolers, the pulse tube cyocooler (PTC) indirectly adjusts the cold phase due to the absence of moving parts at the cold end. The present paper proposed and validated theoretically and experimentally a novel configuration of PTC, termed cold reservoir PTC, in which a reservoir together with an adjustable orifice is connected to the cold end of the pulse tube. The impedance from the additional orifice to the cold end helps to increase the mass flow in phase with the pressure wave at the cold end. Theoretical analyses with the linear model for the orifice and double-inlet PTCs indicate that the cooling performance can be improved by introducing the cold reservoir. The preliminary experiments with a home-made single-stage GM PTC further validated the results on the premise of minor opening of the cold-end orifice.
Experiments in dilution jet mixing
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Srinivasan, R.; Berenfeld, A.
1983-01-01
Experimental results are given on the mixing of a single row of jets with an isothermal mainstream in a straight duct, to include flow and geometric variations typical of combustion chambers in gas turbine engines. The principal conclusions reached from these experiments were: at constant momentum ratio, variations in density ratio have only a second-order effect on the profiles; a first-order approximation to the mixing of jets with a variable temperature mainstream can be obtained by superimposing the jets-in-an isothermal-crossflow and mainstream profiles; flow area convergence, especially injection-wall convergence, significantly improves the mixing; for opposed rows of jets, with the orifice centerlines in-line, the optimum ratio of orifice spacing to duct height is one half of the optimum value for single side injection at the same momentum ratio; and for opposed rows of jets, with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is twice the optimum value for single side injection at the same momentum ratio.
Factors in the Design of Centrifugal Type Injection Valves for Oil Engines
NASA Technical Reports Server (NTRS)
Joachim, W F; Beardsley, E G
1928-01-01
This research was undertaken in connection with a general study of the application of the fuel injection engine to aircraft. The purpose of the investigation was to determine the effect of four important factors in the design of a centrifugal type automatic injection valve on the penetration, general shape, and distribution of oil sprays. The general method employed was to record the development of single sprays by means of special high-speed photographic apparatus capable of taking 25 consecutive pictures of the moving spray at a rate of 4,000 per second. Investigations were made concerning the effects on spray characteristics, of the helix angle of helical grooves, the ratio of the cross-sectional area of the orifice to that of the grooves, the ratio of orifice length to diameter, and the position of the seat. Maximum spray penetration was obtained with a ratio of orifice length to diameter of about 1.5. Slightly greater penetration was obtained with the seat directly before the orifice.
Experimental investigation of crossflow jet mixing in a rectangular duct
NASA Technical Reports Server (NTRS)
Liscinsky, D. S.; True, B.; Holdeman, J. D.
1993-01-01
An experimental investigation of the mixing of nonreacting opposed rows of jets injected normal to a confined rectangular crossflow has been conducted. Planar Mie-scattering was used to measure the time-average concentration distribution of the jet fluid in planes perpendicular to the duct axis. The mixing effectiveness of round orifice injectors was measured as a function of orifice spacing and orifice diameter. Mixing effectiveness was determined using a spatial unmixedness parameter based on the variance of mean jet concentration distributions. Optimum mixing was obtained when the spacing-to-duct height ratio was inversely proportional to the square root of the jet-to-mainstream momentum-flux ratio. For opposed rows of round holes with centerlines inline, mixing was similar for blockages up to 75 percent. Lower levels of unmixedness were obtained as a function of downstream location when axial injection length was minimized. Mixing may be enhanced if orifice centerlines of opposed rows are staggered, but note that blockage must be less than 50 percent for this configuration.
Sensitive glow discharge ion source for aerosol and gas analysis
Reilly, Peter T. A. [Knoxville, TN
2007-08-14
A high sensitivity glow discharge ion source system for analyzing particles includes an aerodynamic lens having a plurality of constrictions for receiving an aerosol including at least one analyte particle in a carrier gas and focusing the analyte particles into a collimated particle beam. A separator separates the carrier gas from the analyte particle beam, wherein the analyte particle beam or vapors derived from the analyte particle beam are selectively transmitted out of from the separator. A glow discharge ionization source includes a discharge chamber having an entrance orifice for receiving the analyte particle beam or analyte vapors, and a target electrode and discharge electrode therein. An electric field applied between the target electrode and discharge electrode generates an analyte ion stream from the analyte vapors, which is directed out of the discharge chamber through an exit orifice, such as to a mass spectrometer. High analyte sensitivity is obtained by pumping the discharge chamber exclusively through the exit orifice and the entrance orifice.
On Small Disturbance Ascent Vent Behavior
NASA Technical Reports Server (NTRS)
Woronowicz, Michael
2015-01-01
As a spacecraft undergoes ascent in a launch vehicle, its ambient pressure environment transitions from one atmosphere to high vacuum in a matter of a few minutes. Venting of internal cavities is necessary to prevent the buildup of pressure differentials across cavity walls. These pressure differentials are often restricted to low levels to prevent violation of container integrity. Such vents usually consist of fixed orifices, ducts, or combinations of both. Duct conductance behavior is fundamentally different from that for orifices in pressure driven flows governing the launch vehicle ascent depressurization environment. Duct conductance is governed by the average pressure across its length, while orifice conductance is dictated by a pressure ratio. Hence, one cannot define a valid equivalent orifice for a given duct across a range of pressure levels. This presentation discusses development of expressions for these two types of vent elements in the limit of small pressure differentials, explores conditions for their validity, and compares their features regarding ascent depressurization performance.
Simulation of air velocity in a vertical perforated air distributor
NASA Astrophysics Data System (ADS)
Ngu, T. N. W.; Chu, C. M.; Janaun, J. A.
2016-06-01
Perforated pipes are utilized to divide a fluid flow into several smaller streams. Uniform flow distribution requirement is of great concern in engineering applications because it has significant influence on the performance of fluidic devices. For industrial applications, it is crucial to provide a uniform velocity distribution through orifices. In this research, flow distribution patterns of a closed-end multiple outlet pipe standing vertically for air delivery in the horizontal direction was simulated. Computational Fluid Dynamics (CFD), a tool of research for enhancing and understanding design was used as the simulator and the drawing software SolidWorks was used for geometry setup. The main purpose of this work is to establish the influence of size of orifices, intervals between outlets, and the length of tube in order to attain uniformity of exit flows through a multi outlet perforated tube. However, due to the gravitational effect, the compactness of paddy increases gradually from top to bottom of dryer, uniform flow pattern was aimed for top orifices and larger flow for bottom orifices.
Fine-pore aeration diffusers: accelerated membrane ageing studies.
Kaliman, An; Rosso, Diego; Leu, Shao-Yuan; Stenstrom, Michael K
2008-01-01
Polymeric membranes are widely used in aeration systems for biological treatment. These membranes may degrade over time and are sensitive to fouling and scaling. Membrane degradation is reflected in a decline in operating performance and higher headloss, resulting in increased energy costs. Mechanical property parameters, such as membrane hardness, Young's modulus, and orifice creep, were used to characterize the performance of membranes over time in operation and to predict their failure. Used diffusers from municipal wastewater treatment plants were collected and tested for efficiency and headloss, and then dissected to facilitate measurements of Young's modulus, hardness, and orifice creep. Higher degree of membrane fouling corresponded consistently with larger orifice creep. A lab-scale membrane ageing simulation was performed with polyurethane and four different ethylene-propylene-diene (EPDM) membrane diffusers by subjecting them to chemical ageing cycles and periodic testing. The results confirmed full-scale plant results and showed the superiority of orifice creep over Young's modulus and hardness in predicting diffuser deterioration.
Research yields precise uncertainty equations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, E.H.; Ferguson, K.R.
1987-08-03
Results of a study of orifice-meter accuracy by Chevron Oil Field Research Co. at its Venice, La., calibration facility have important implications for natural gas custody-transfer measurement. The calibration facility, data collection, and equipment calibration were described elsewhere. This article explains the derivation of uncertainty factors and details the study's findings. The results were based on calibration of two 16-in. orifice-meter runs. The experimental data cover a beta-ratio range of from 0.27 to 0.71 and a Reynolds number range of from 4,000,000 to 35,000,000. Discharge coefficients were determined by comparing the orifice flow to the flow from critical-flow nozzles.
Stirrup, James E; Cowburn, Peter J; Pousios, Dimitrios; Ohri, Sunil K; Shah, Benoy N
2016-09-01
Transesophageal echocardiography (TEE) is a powerful imaging tool for the comprehensive assessment of valvular structure and function. TEE may be of added benefit when anatomy is difficult to delineate accurately by transthoracic echocardiography. In this article, we present 2-, 3-dimensional, and color Doppler TEE images from a male patient with aortic stenosis. A highly unusual and complex pattern of valvular calcification created a functionally "double-orifice" valve. Such an abnormality may have implications for the accuracy of continuous-wave Doppler echocardiography, which assumes a single orifice valve in native aortic valves. © 2016, Wiley Periodicals, Inc.
Plasma arc welding torch having means for vortexing plasma gas exiting the welding torch
NASA Technical Reports Server (NTRS)
Rybicki, Daniel J. (Inventor); Mcgee, William F. (Inventor)
1994-01-01
A plasma arc welding torch is described wherein a plasma gas is directed through the body of the welding torch and out of the body across the tip of the welding electrode disposed at the forward end of the body. The plasma gas is provided with a vortexing motion prior to exiting the body by a vortex motion imparting member which is mounted in an orifice housing member and carried in the forward portion of the torch body. The orifice housing member is provided with an orifice of an predetermined diameter through which the electric arc and the plasma gas exits.
Acoustic response of a rectangular levitator with orifices
NASA Technical Reports Server (NTRS)
El-Raheb, Michael; Wagner, Paul
1990-01-01
The acoustic response of a rectangular cavity to speaker-generated excitation through waveguides terminating at orifices in the cavity walls is analyzed. To find the effects of orifices, acoustic pressure is expressed by eigenfunctions satisfying Neumann boundary conditions as well as by those satisfying Dirichlet ones. Some of the excess unknowns can be eliminated by point constraints set over the boundary, by appeal to Lagrange undetermined multipliers. The resulting transfer matrix must be further reduced by partial condensation to the order of a matrix describing unmixed boundary conditions. If the cavity is subjected to an axial temperature dependence, the transfer matrix is determined numerically.
Maddox, James W.; Berger, David D.
1984-01-01
A condensate removal device is disclosed which incorporates a strainer in unit with an orifice. The strainer is cylindrical with its longitudinal axis transverse to that of the vapor conduit in which it is mounted. The orifice is positioned inside the strainer proximate the end which is remoter from the vapor conduit.
Zanatta, Rayssa Ferreira; Barreto, Bruno de Castro Ferreira; Xavier, Tathy Aparecida; Versluis, Antheunis; Soares, Carlos José
2015-02-01
This study evaluated the influence of punch and base orifice diameters on push-out test results by means of finite element analysis (FEA). FEA was performed using 3D models of the push-out test with 3 base orifice diameters (2.5, 3.0, and 3.5 mm) and 3 punch diameters (0.5, 1.0, and 1.5 mm) using MARC/MENTAT (MSC.Software). The image of a cervical slice from a root restored with a fiberglass post was used to construct the models. The mechanical properties of dentin, post, and resin cement were obtained from the literature. Bases and punches were constructed as rigid bodies. A 10-N force was applied by the punch in the center of the post in a nonlinear contact analysis. Modified von Mises stress, maximum principal stress, as well as shear and normal stress components were calculated. Both punch and base orifice sizes influenced the stress distribution of the push-out test. Bases with larger diameters and punches with smaller diameters caused higher stress in dentin and at the dentin/cement interface. FEA showed that the diameter of the orifice base had a more significant influence on the stress distribution than did the punch diameter. For this reason, both factors should be taken into account during push-out experimental tests.
Kim, Joo Dong; Choi, Dong Lak; Han, Young Seok
2014-05-01
Middle hepatic vein (MHV) reconstruction is often essential to avoid hepatic congestion and serious graft dysfunction in living donor liver transplantation (LDLT). The aim of this report was to introduce evolution of our MHV reconstruction technique and excellent outcomes of simplified one-orifice venoplasty. We compared clinical outcomes with two reconstruction techniques through retrospective review of 95 recipients who underwent LDLT using right lobe grafts at our institution from January 2008 to April 2012; group 1 received separate outflow reconstruction and group 2 received new one-orifice technique. The early patency rates of MHV in group 2 were higher than those in group 1; 98.4% vs. 88.2% on postoperative day 7 (p = 0.054) and 96.7% vs. 82.4% on postoperative day 14, respectively (p = 0.023). Right hepatic vein (RHV) stenosis developed in three cases in group 1, but no RHV stenosis developed because we adopted one-orifice technique (p = 0.043). The levels of aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in group 2 were significantly lower than those in group 1 during the early post-transplant period. In conclusion, our simplified one-orifice venoplasty technique could secure venous outflow and improve graft function during right lobe LDLT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Bubble Formation from Wall Orifice in Liquid Cross-Flow Under Low Gravity
NASA Technical Reports Server (NTRS)
Nahra, Henry K.; Kamotani, Y.
2000-01-01
Two-phase flows present a wide variety of applications for spacecraft thermal control systems design. Bubble formation and detachment is an integral part of the two phase flow science. The objective of the present work is to experimentally investigate the effects of liquid cross-flow velocity, gas flow rate, and orifice diameter on bubble formation in a wall-bubble injection configuration. Data were taken mainly under reduced gravity conditions but some data were taken in normal gravity for comparison. The reduced gravity experiment was conducted aboard the NASA DC-9 Reduced Gravity Aircraft. The results show that the process of bubble formation and detachment depends on gravity, the orifice diameter, the gas flow rate, and the liquid cross-flow velocity. The data are analyzed based on a force balance, and two different detachment mechanisms are identified. When the gas momentum is large, the bubble detaches from the injection orifice as the gas momentum overcomes the attaching effects of liquid drag and inertia. The surface tension force is much reduced because a large part of the bubble pinning edge at the orifice is lost as the bubble axis is tilted by the liquid flow. When the gas momentum is small, the force balance in the liquid flow direction is important, and the bubble detaches when the bubble axis inclination exceeds a certain angle.
Variable orifice using an iris shutter
Beeman, Raymond; Brajkovich, Steven J.
1978-01-01
A variable orifice forming mechanism utilizing an iris shutter arrangement adapted to control gas flow, conductance in vacuum systems, as a heat shield for furnace windows, as a beam shutter in sputtering operations, and in any other application requiring periodic or continuously-variable control of material, gas, or fluid flow.
Some Characteristics of Fuel Sprays from Open Nozzles
NASA Technical Reports Server (NTRS)
Rothrock, A M; Lee, D W
1930-01-01
The penetration and cone-angle of fuel sprays from open nozzles were recorded with the NACA Spray Photography Equipment. The results show that for injection systems in which the rate of pressure rise at the discharge orifice is high, open nozzles give spray-tip velocities and penetrations which compare favorably with those of closed nozzles. The spray cone-angle was the same for all tests, although open nozzles having different orifice diameters were used, and one nozzle was used both as an open and as a closed nozzle. In designing a fuel system using open nozzles, particular care must be taken to avoid air pockets. The check valve should be placed close to the discharge orifice.
NASA Technical Reports Server (NTRS)
Mchale, R. M.
1974-01-01
Results are presented of a cold-flow and hot-fire experimental study of the mixing and atomization characteristics of injector elements incorporating noncircular orifices. Both liquid/liquid and gas/liquid element types are discussed. Unlike doublet and triplet elements (circular orifices only) were investigated for the liquid/liquid case while concentric tube elements were investigated for the gas/liquid case. It is concluded that noncircular shape can be employed to significant advantage in injector design for liquid rocket engines.
NASA Technical Reports Server (NTRS)
Dejong, J.; Spencer, E. A.
1983-01-01
A 205 mm transfer standard orifice plate meter assembly, consisting of two orifice plates in series separated by a length of pipe containing a flow straightener, was calibrated in two water flow facilities. Results show that the agreement in the characteristics of such a differential pressure transfer standard package is within 0.17% over a 10:1 range from flow rates of approximately 8 to 80 l/sec. When the range over which the comparison was made was limited to that for which the calibration graphs gave straight lines, the agreement is 0.1% in 3 of the 4 calibrations (0.17% in the fourth).
A sticky situation: management of spray polyurethane foam insulation in body orifices.
Sowerby, Robert J; Sowerby, Leigh J; Vinden, Chris
2011-11-01
Spray polyurethane foam insulation is commonly used in the construction industry to fill gaps, seal, and insulate. We present three cases of intentional spray foam insertion in body orifices and discuss the management of such situations in the emergency department. This series includes a case of oral foam insertion used in a suicide attempt by suffocation and two cases of rectal insertion. All of these cases had potential long-term consequences; one was life-threatening. To our knowledge, this is the first published report on the medical management and removal of foam insulation from body orifices. In all three cases, the foam insulation material was successfully removed after allowing the material to harden.
Hydraulic servo control spool valve
Miller, Donald M.
1983-01-01
A servo operated spool valve having a fixed sleeve and axially movable spool. The sleeve is machined in two halves to form a long, narrow tapered orifice slot across which a transverse wall of the spool is positioned. The axial position of the spool wall along the slot regulates the open orifice area with extreme precision.
Microscreen radiation shield for thermoelectric generator
Hunt, Thomas K.; Novak, Robert F.; McBride, James R.
1990-01-01
The present invention provides a microscreen radiation shield which reduces radiative heat losses in thermoelectric generators such as sodium heat engines without reducing the efficiency of operation of such devices. The radiation shield is adapted to be interposed between a reaction zone and a means for condensing an alkali metal vapor in a thermoelectric generator for converting heat energy directly to electrical energy. The radiation shield acts to reflect infrared radiation emanating from the reaction zone back toward the reaction zone while permitting the passage of the alkali metal vapor to the condensing means. The radiation shield includes a woven wire mesh screen or a metal foil having a plurality of orifices formed therein. The orifices in the foil and the spacing between the wires in the mesh is such that radiant heat is reflected back toward the reaction zone in the interior of the generator, while the much smaller diameter alkali metal atoms such as sodium pass directly through the orifices or along the metal surfaces of the shield and through the orifices with little or no impedance.
Preparation of spherical particles by vibrating orifice technique
NASA Astrophysics Data System (ADS)
Shibata, Shuichi; Tomizawa, Atsushi; Yoshikawa, Hidemi; Yano, Tetsuji; Yamane, Masayuki
2000-05-01
Preparation of micrometer-sized spherical particles containing Rhodamine 6G (R6G) has been investigated for the spherical cavity micro-laser. Using phenyl triethoxy silane (PTES) as a starting material, R6G-doped monodisperse spherical particles were prepared by the vibrating orifice technique. Processing consists of two major processes: (1) Hydrolysis and polymerization of PTES and (2) Droplet formation from PTES oligomers by vibrating orifice technique. A cylindrical liquid jet passing through the orifice of 10 and 20 micrometers in diameter breaks up into equal- sized droplets by mechanical vibration. Alcohol solvent of these droplets was evaporated during flying with carrier gas and subsequently solidified in ammonium water trap. For making smooth surface and god shaped particles, control of molecular weight of PTES oligomer was essential. R6G-doped hybrid spherical particles of 4 to 10 micrometers size of cavity structure were successfully obtained. The spherical particles were pumped by a second harmonic pulse of Q- switched Nd:YAG laser and laser emission peaks were observed at wavelengths which correspond to the resonance modes.
Velocity profile survey in a 16-in. custody-transfer orifice meter for natural gas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, J.J.S.
1991-02-01
This paper describes a research project conducted at Chevron U.S.A. Inc.'s Venice, LA, facility to ascertain that the flow condition inside a nominal 16-in. (406-mm) custody-transfer orifice meter was in compliance with American Gas Assn. (AGA) requirements. The survey was conducted at four flow rates ranging from 160 to 200 MMscf/D (4.53 {times} 10{sup 6} to 5.66 {times} 10{sup 6} std m{sup 3}/d) of processed natural gas at 880 psia (6.1 MPa). Experimental data were collected by a portable data-acquisition system driven by a lap-top microcomputer. The measured profiles indicated that the flow was nearly fully developed at the orificemore » plate location, and no significant swirling motion was detected. This test successfully demonstrated the techniques and equipment developed for determining actual flow distributions inside orifice meters in the field under normal operating conditions. This technology can be used to detect detrimental flow profiles and to verify compliance with AGA requirements on flow conditions in custody-transfer orifice meters.« less
Experiments in dilution jet mixing
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Srinivasan, R.; Berenfeld, A.
1983-01-01
Experimental results are presented on the mixing of a single row of jets with an isothermal mainstream in a straight duct, with flow and geometric variations typical of combustion chambers in gas turbine engines included. It is found that at a constant momentum ratio, variations in the density ratio have only a second-order effect on the profiles. A first-order approximation to the mixing of jets with a variable temperature mainstream can, it is found, be obtained by superimposing the jets-in-an-isothermal-crossflow and mainstream profiles. Another finding is that the flow area convergence, especially injection-wall convergence, significantly improves the mixing. For opposed rows of jets with the orifice cone centerlines in-line, the optimum ratio of orifice spacing to duct height is determined to be 1/2 of the optimum value for single injection at the same momentum ratio. For opposed rows of jets with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is found to be twice the optimum value for single side injection at the same momentum ratio.
Application of X-ray micro-computed tomography on high-speed cavitating diesel fuel flows
NASA Astrophysics Data System (ADS)
Mitroglou, N.; Lorenzi, M.; Santini, M.; Gavaises, M.
2016-11-01
The flow inside a purpose built enlarged single-orifice nozzle replica is quantified using time-averaged X-ray micro-computed tomography (micro-CT) and high-speed shadowgraphy. Results have been obtained at Reynolds and cavitation numbers similar to those of real-size injectors. Good agreement for the cavitation extent inside the orifice is found between the micro-CT and the corresponding temporal mean 2D cavitation image, as captured by the high-speed camera. However, the internal 3D structure of the developing cavitation cloud reveals a hollow vapour cloud ring formed at the hole entrance and extending only at the lower part of the hole due to the asymmetric flow entry. Moreover, the cavitation volume fraction exhibits a significant gradient along the orifice volume. The cavitation number and the needle valve lift seem to be the most influential operating parameters, while the Reynolds number seems to have only small effect for the range of values tested. Overall, the study demonstrates that use of micro-CT can be a reliable tool for cavitation in nozzle orifices operating under nominal steady-state conditions.
Flow-induced resonance of screen-covered cavities
NASA Technical Reports Server (NTRS)
Soderman, Paul T.
1990-01-01
An experimental study of screen-covered cavities exposed to airflow tangent to the screen is described. The term screen refers to a thin metal plate perforated with a repetitive pattern of round holes. The purpose was to find the detailed aerodynamic and acoustic mechanisms responsible for screen-covered cavity resonance and to find ways to control the pressure oscillations. Results indicate that strong cavity acoustic resonances are created by screen orifices that shed vortices which couple resonance by choosing hole spacings such that shed vortices do not arrive at a downstream orifice in synchronization with cavity pressure oscillations. The proper hole pattern is effective at all airspeeds. It was also discovered that a reduction of orifice size tended to weaken the screen/cavity interaction regardless of hole pattern, probably because of viscous flow losses at the orifices. The screened cavities that resonated did so at much higher frequencies than the equivalent open cavity. The classical large eddy phenomenon occurs at the relatively small scale of the orifices (the excitation is typically of high frequency). The wind tunnel study was made at airspeeds from 0 to 100m/sec. The 457-mm-long by 1.09-m-high rectangular cavities had length-to-depth ratios greater than one, which is indicative of shallow cavities. The cavity screens were perforated in straight rows and columns with hole diameters ranging from 1.59 to 6.35 mm and with porosities from 2.6 to 19.6 percent.
Production of Gas Bubbles in Reduced Gravity Environments
NASA Technical Reports Server (NTRS)
Oguz, Hasan N.; Takagi, Shu; Misawa, Masaki
1996-01-01
In a wide variety of applications such as waste water treatment, biological reactors, gas-liquid reactors, blood oxygenation, purification of liquids, etc., it is necessary to produce small bubbles in liquids. Since gravity plays an essential role in currently available techniques, the adaptation of these applications to space requires the development of new tools. Under normal gravity, bubbles are typically generated by forcing gas through an orifice in a liquid. When a growing bubble becomes large enough, the buoyancy dominates the surface tension force causing it to detach from the orifice. In space, the process is quite different and the bubble may remain attached to the orifice indefinitely. The most practical approach to simulating gravity seems to be imposing an ambient flow to force bubbles out of the orifice. In this paper, we are interested in the effect of an imposed flow in 0 and 1 g. Specifically, we investigate the process of bubble formation subject to a parallel and a cross flow. In the case of parallel flow, we have a hypodermic needle in a tube from which bubbles can be produced. On the other hand, the cross flow condition is established by forcing bubbles through an orifice on a wall in a shear flow. The first series of experiments have been performed under normal gravity conditions and the working fluid was water. A high quality microgravity facility has been used for the second type and silicone oil is used as the host liquid.
Yasa, E; Arslan, H; Yasa, B; Akcay, M; Alsancak, M; Hatirli, H
2017-10-01
To evaluate the effect of various materials as intra-orifice barriers on the force required fracture roots. One hundred-thirty five mandibular premolars were decoronated and prepared up to size #40. The root canals were filled and randomly divided into two control and seven experimental groups (n = 15), as follows: Positive control group (the intra-orifice barrier cavity was not prepared), negative control group (the intra-orifice barrier cavity was prepared, but not filled), filling using glass ionomer cement, nano-hybrid composite resin, short fiber-reinforced composite, bulk-fill flowable composite, MTA Angelus, Micro Mega MTA or Biodentine. A fracture strength test was performed, and the data were analyzed using one-way ANOVA and Tukey's post hoc tests. Nano-hybrid composite, short fiber-reinforced composite, bulk-fill flow able composite, and glass ionomer cement increased the force required fracture the roots compared to the positive and negative control groups (P < 0.05). While MTA groups did not increase the force required fracture the roots compared to the control groups, Biodentine increased significantly. Within the limitations of the present study, the use of nano-hybrid composite, short fiber-reinforced composite, bulk-fill flowable composite, and glass ionomer cement as an intra-orifice barrier may be useful in reinforcing roots. MTA placement (MTA Angelus or Micro Mega MTA) did not significantly increase the fracture resistance of endodontically treated roots compared to the control groups, however Biodentine did.
Design of an Orifice and Weir Outlet for Poorly Drained Forested Watersheds
D.M. Amatya; R.W. Skaggs; J.H. Hughes
1999-01-01
Orifice-weir structures at ditch outlets are being used to reduce peak drainage rates and to store water during the growing season in poorly drained managed pine plantations. Earlier studies have shown their effectiveness on reducing drainage outflows while conserving water during the growing season. This study reports on criteria and preliminary guidelines for...
Marsden, Kenneth C.; Meyer, Mitchell K.; Grover, Blair K.; Fielding, Randall S.; Wolfensberger, Billy W.
2012-12-18
A casting device includes a covered crucible having a top opening and a bottom orifice, a lid covering the top opening, a stopper rod sealing the bottom orifice, and a reusable mold having at least one chamber, a top end of the chamber being open to and positioned below the bottom orifice and a vacuum tap into the chamber being below the top end of the chamber. A casting method includes charging a crucible with a solid material and covering the crucible, heating the crucible, melting the material, evacuating a chamber of a mold to less than 1 atm absolute through a vacuum tap into the chamber, draining the melted material into the evacuated chamber, solidifying the material in the chamber, and removing the solidified material from the chamber without damaging the chamber.
NASA Astrophysics Data System (ADS)
Cao, M.-H.; Jiang, H.-K.; Chin, J.-S.
1982-04-01
An improved flat-fan spray model is used for the semi-empirical analysis of liquid fuel distribution downstream of a plain orifice injector under cross-stream air flow. The model assumes that, due to the aerodynamic force of the high-velocity cross air flow, the injected fuel immediately forms a flat-fan liquid sheet perpendicular to the cross flow. Once the droplets have been formed, the trajectories of individual droplets determine fuel distribution downstream. Comparison with test data shows that the proposed model accurately predicts liquid fuel distribution at any point downstream of a plain orifice injector under high-velocity, low-temperature uniform cross-stream air flow over a wide range of conditions.
Volumetric dispenser for small particles from plural sources
Bradley, R.A.; Miller, W.H.; Sease, J.D.
1975-12-16
Apparatus is described for rapidly and accurately dispensing measured volumes of small particles from a supply hopper. The apparatus includes an adjustable, vertically oriented measuring tube and orifice member defining the volume to be dispensed, a ball plug valve for selectively closing the bottom end of the orifice member, and a compression valve for selectively closing the top end of the measuring tube. A supply hopper is disposed above and in gravity flow communication with the measuring tube. Properly sequenced opening and closing of the two valves provides accurate volumetric discharge through the ball plug valve. A dispensing system is described wherein several appropriately sized measuring tubes, orifice members, and associated valves are arranged to operate contemporaneously to facilitate blending of different particles.
NASA Technical Reports Server (NTRS)
Mcdaniel, J. C.; Graves, J., Jr.
1986-01-01
The present paper reports work which has been conducted in the first phase of a research program which is to provide a data base of spatially-resolved measurements in nonreacting supersonic combustors. In the measurements, a nonintrusive diagnostic technique based on the utilization of laser-induced fluorescence (LIF) is employed. The reported work had the objective to conduct LIF visualization studies of the injection of a simulated fuel into a Mach 2.07 airstream for comparison with corresponding numerical calculations. Attention is given to injection from a single orifice into a constant-area duct, injection from a single orifice behind a rearward-facing step, and injection from staged orifices behind a rearward-facing step.
[Preparation of ondansetron hydrochloride osmotic pump tablets and their in vitro drug release].
Zheng, Hang-sheng; Bi, Dian-zhou
2005-12-01
To prepare ondansetron hydrochloride osmotic pump tablets (OND-OPT) and investigate their in vitro drug release behavior. OND-OPT were prepared with a single punch press and pan coating technique. Osmotic active agents and plasticizer of coating film were chosen by drug release tests. The effects of the number, position and direction of drug release orifice on release behavior were investigated. The relation between drug release duration and thickness of coating film, PEG content of coating film and size of drug release orifice was established by uniform design experiment. The surface morphological change of coating film before and after drug release test was observed by scanning electron microscopy. The osmotic pumping release mechanism of OND-OPT was confirmed by drug release test with high osmotic pressure medium. Lactose-mannitol (1:2) was chosen as osmotic active agents and PEG400 as plasticizer of coating film. The direction of drug release orifice had great effect on the drug release of OND-OPT without HPMC, and had no effect on the drug release of OND-OPT with HPMC. The OND-OPT with one drug release orifice at the centre of the coating film on one surface of tablet released their drug with little fluctuation. The drug release duration of OND-OPT correlated with thickness of coating film and PEG content of coating film, and didn't correlate significantly with the size of drug release orifice. OND-OPT released their drug with osmotic pumping mechanism predominantly. OND-OPT are able to realize ideal controlled drug release.
Quick-Mixing Studies Under Reacting Conditions
NASA Technical Reports Server (NTRS)
Leong, May Y.; Samuelsen, G. S.
1996-01-01
The low-NO(x) emitting potential of rich-burn/quick-mix/lean-burn )RQL) combustion makes it an attractive option for engines of future stratospheric aircraft. Because NO(x) formation is exponentially dependent on temperature, the success of the RQL combustor depends on minimizing high temperature stoichiometric pocket formation in the quick-mixing section. An experiment was designed and built, and tests were performed to characterize reaction and mixing properties of jets issuing from round orifices into a hot, fuel-rich crossflow confined in a cylindrical duct. The reactor operates on propane and presents a uniform, non-swirling mixture to the mixing modules. Modules consisting of round orifice configurations of 8, 9, 10, 12, 14, and 18 holes were evaluated at a momentum-flux ratio of 57 and jet-to-mainstream mass-flaw ratio of 2.5. Temperatures and concentrations of O2, CO2, CO, HC, and NO(x) were obtained upstream, down-stream, and within the orifice plane to determine jet penetration as well as reaction processes. Jet penetration was a function of the number of orifices and affected the mixing in the reacting system. Of the six configurations tested, the 14-hole module produced jet penetration close to the module half-radius and yielded the best mixing and most complete combustion at a plane one duct diameter from the orifice leading edge. The results reveal that substantial reaction and heat release occur in the jet mixing zone when the entering effluent is hot and rich, and that the experiment as designed will serve to explore satisfactorily jet mixing behavior under realistic reacting conditions in future studies.
Numerical study of liquid-hydrogen droplet generation from a vibrating orifice
NASA Astrophysics Data System (ADS)
Xu, J.; Celik, D.; Hussaini, M. Y.; Van Sciver, S. W.
2005-08-01
Atomic hydrogen propellant feed systems for far-future spacecraft may utilize solid-hydrogen particle carriers for atomic species that undergo recombination to create hot rocket exhaust. Such technology will require the development of particle generation techniques. One such technique could involve the production of hydrogen droplets from a vibrating orifice that would then freeze in cryogenic helium vapor. Among other quantities, the shape and size of the droplet are of particular interest. The present paper addresses this problem within the framework of the incompressible Navier-Stokes equations for multiphase flows, in order to unravel the basic mechanisms of droplet formation with a view to control them. Surface tension, one of the most important mechanisms to determine droplet shape, is modeled as the source term in the momentum equation. Droplet shape is tracked using a volume-of-fluid approach. A dynamic meshing technique is employed to accommodate the vibration of the generator orifice. Numerically predicted droplet shapes show satisfactory agreement with photographs of droplets generated in experiments. A parametric study is carried out to understand the influence of injection velocity, nozzle vibrational frequency, and amplitude on the droplet shape and size. The computational model provides a definitive qualitative picture of the evolution of droplet shape as a function of the operating parameters. It is observed that, primarily, the orifice vibrational frequency affects the shape, the vibrational amplitude affects the time until droplet detachment from the orifice, and the injection velocity affects the size. However, it does not mean that, for example, there is no secondary effect of amplitude on shape or size.
An optimized video system for augmented reality in endodontics: a feasibility study.
Bruellmann, D D; Tjaden, H; Schwanecke, U; Barth, P
2013-03-01
We propose an augmented reality system for the reliable detection of root canals in video sequences based on a k-nearest neighbor color classification and introduce a simple geometric criterion for teeth. The new software was implemented using C++, Qt, and the image processing library OpenCV. Teeth are detected in video images to restrict the segmentation of the root canal orifices by using a k-nearest neighbor algorithm. The location of the root canal orifices were determined using Euclidean distance-based image segmentation. A set of 126 human teeth with known and verified locations of the root canal orifices was used for evaluation. The software detects root canals orifices for automatic classification of the teeth in video images and stores location and size of the found structures. Overall 287 of 305 root canals were correctly detected. The overall sensitivity was about 94 %. Classification accuracy for molars ranged from 65.0 to 81.2 % and from 85.7 to 96.7 % for premolars. The realized software shows that observations made in anatomical studies can be exploited to automate real-time detection of root canal orifices and tooth classification with a software system. Automatic storage of location, size, and orientation of the found structures with this software can be used for future anatomical studies. Thus, statistical tables with canal locations will be derived, which can improve anatomical knowledge of the teeth to alleviate root canal detection in the future. For this purpose the software is freely available at: http://www.dental-imaging.zahnmedizin.uni-mainz.de/.
Automatic coolant flow control device for a nuclear reactor assembly
Hutter, E.
1984-01-27
A device which controls coolant flow through a nuclear reactor assembly comprises a baffle means at the exit end of said assembly having a plurality of orifices, and a bimetallic member in operative relation to the baffle means such that at increased temperatures said bimetallic member deforms to unblock some of said orifices and allow increased coolant flow therethrough.
Automatic coolant flow control device for a nuclear reactor assembly
Hutter, Ernest
1986-01-01
A device which controls coolant flow through a nuclear reactor assembly comprises a baffle means at the exit end of said assembly having a plurality of orifices, and a bimetallic member in operative relation to the baffle means such that at increased temperatures said bimetallic member deforms to unblock some of said orifices and allow increased coolant flow therethrough.
Precipitation measurements on wind-swept slopes
Austin E. Helmers
1954-01-01
Precipitation catch for three calendar years is compared for four types of gage installation on a wind-swept south-facing slope with a 22° gradient at elevation 5500 ft. The 1950 precipitation catch by (1) weighing-recording gage with the orifice and an Alter type wind shield sloped parallel to the ground surface, (2) unshielded nonrecording gage with orifice sloped...
Determining the Coefficient of Discharge for a Draining Container
ERIC Educational Resources Information Center
Hicks, Ashley; Slaton, William
2014-01-01
The flow of fluids through open containers is a topic studied frequently in introductory physics classes. A fluid mechanics class delves deeper into the topic of fluid flow through open containers with holes or barriers. The flow of a fluid jet out of a sharp-edged orifice rarely has the same area as the orifice due to a fluid flow phenomenon…
40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures
Code of Federal Regulations, 2014 CFR
2014-07-01
... transmitters of an orifice-, nozzle-, or venturi-type fuel flowmeter under section 2.1.6 of appendix D to this... nozzle) of an orifice-, venturi-, or nozzle-type fuel flowmeter. Examples of the types of information to..., but ≤200 ppm). The out-of-control period begins upon failure of the calibration error test and ends...
Head loss coefficient through sharp-edged orifices
NASA Astrophysics Data System (ADS)
Adam, Nicolas J.; De Cesare, Giovanni; Schleiss, Anton J.; Richard, Sylvain; Muench-Alligné, Cécile
2016-11-01
Nowadays, high-head power plants could increase their installed power capacity for many reasons, e.g. dam heightening, increase of their peak power capacity or refurbishment with new turbines. Frequently, due to several considerations, e.g. topographical or economical limitations, the existing surge tank cannot be extended to keep previous safety levels and efficiency. A valuable way to adapt these surge tanks is to place a throttle at their entrance like, for example, an orifice. The main effect of this adaptation is the introduction of head losses that reduce the extreme levels in the surge tank due to the mass oscillations resulting from a closure or opening of downstream discharge control. This research studies the influence of the edge angle of a ASME-standard orifice on the head losses. This angle introduces an asymmetrical behavior and influences head losses. Different angles are tested from 0° to the 67° (biggest angle possible for this configuration). The first step of this study is to determine experimentally the steady losses produced by orifice for several discharges. In the second step, a numerical model on ANSYS CFX is performed. Combining the two approaches, it is possible to understand and quantify the effect of the edge angle.
Jet Mixing in a Reacting Cylindrical Crossflow
NASA Technical Reports Server (NTRS)
Leong, M. Y.; Samuelsen, G. S.; Holdeman, J. D.
1995-01-01
This paper addresses the mixing of air jets into the hot, fuel-rich products of a gas turbine primary zone. The mixing, as a result, occurs in a reacting environment with chemical conversion and substantial heat release. The geometry is a crossflow confined in a cylindrical duct with side-wall injection of jets issuing from round orifices. A specially designed reactor, operating on propane, presents a uniform mixture without swirl to mixing modules consisting of 8, 9, 10, and 12 holes at a momentum-flux ratio of 57 and a jet-to-mainstream mass-flow ratio of 2.5. Concentrations of O2, CO2, CO, and HC are obtained upstream, downstream, and within the orifice plane. O2 profiles indicate jet penetration while CO2, CO, and HC profiles depict the extent of reaction. Jet penetration is observed to be a function of the number of orifices and is found to affect the mixing in the reacting system. The results demonstrate that one module (the 12-hole) produces near-optimal penetration defined here as a jet penetration closest to the module half-radius, and hence the best uniform mixture at a plane one duct radius from the orifice leading edge.
A Particle and Energy Balance Model of the Orificed Hollow Cathode
NASA Technical Reports Server (NTRS)
Domonkos, Matthew T.
2002-01-01
A particle and energy balance model of orificed hollow cathodes was developed to assist in cathode design. The model presented here is an ensemble of original work by the author and previous work by others. The processes in the orifice region are considered to be one of the primary drivers in determining cathode performance, since the current density was greatest in this volume (up to 1.6 x 10(exp 8) A/m2). The orifice model contains comparatively few free parameters, and its results are used to bound the free parameters for the insert model. Next, the insert region model is presented. The sensitivity of the results to the free parameters is assessed, and variation of the free parameters in the orifice dominates the calculated power consumption and plasma properties. The model predictions are compared to data from a low-current orificed hollow cathode. The predicted power consumption exceeds the experimental results. Estimates of the plasma properties in the insert region overlap Langmuir probe data, and the predicted orifice plasma suggests the presence of one or more double layers. Finally, the model is used to examine the operation of higher current cathodes.
Integrated Fuel Injection and Mixing System with Impingement Cooling Face
NASA Technical Reports Server (NTRS)
Mansour, Adel B. (Inventor); Harvey, Rex J. (Inventor); Tacina, Robert R. (Inventor); Laing, Peter (Inventor)
2003-01-01
An atomizing injector includes a metering set having a swirl chamber, a spray orifice and one or more feed slots etched in a thin plate. The swirl chamber is etched in a first side of the plate and the spray orifice is etched through a second side to the center of the swirl chamber. Fuel feed slots extend non-radially to the swirl chamber. The injector also includes integral swirler structure. The swirler structure includes a cylindrical air swirler passage, also shaped by etching, through at least one other thin plate. The cylindrical air swirler passage is located in co-axial relation to the spray orifice of the plate of the fuel metering set such that fuel directed through the spray orifice passes through the air swirler passage and swirling air is imparted to the fuel such that the fuel has a swirling component of motion. At least one air feed slot is provided in fluid communication with the air swirler passage and extends in non-radial relation thereto. Air supply passages extend through the plates of the metering set and the swirler structure to feed the air feed slot in each plate of the swirler structure.
Investigation of the external flow analysis for density measurements at high altitude
NASA Technical Reports Server (NTRS)
Bienkowski, G. K.
1984-01-01
The results of analysis performed on the external flow around the shuttle orbiter nose regions at the Shuttle Upper Atmosphere Mass Spectrometer (SUMS) inlet orifice are presented. The purpose of the analysis is to quantitatively characterize the flow conditions to facilitate SUMS flight data reduction and subsequent determination of orbiter aerodynamic force coefficients in the hypersonic rarefied flow regime. Experimental determination of aerodynamic force coefficients requires accurate simultaneous measurement of forces (or acceleration) and dynamic pressure along with independent knowledge of density and velocity. The SUMS provides independent measurement of dynamic pressure; however, it does so indirectly and requires knowledge of the relationship between measured orifice conditions and the dynamic pressure which can only be determined on the basis of molecule or theory for a winged configuration. Monte Carlo direct simulation computer codes were developed for both the flow field solution at the orifice and for the internal orifice flow. These codes were used to study issues associated with geometric modeling of the orbiter nose geometry and the modeling of intermolecular collisions including rotational energy exchange and a preliminary analysis of vibrational excitation and dissociation effects. Data obtained from preliminary simulation runs are presented.
Seitz, W; Oppenheimer, L; McIlroy, M; Nelson, D; Operschall, J
1986-12-01
An orifice equation is derived relating the effective aortic valve area, A, the average aortic valve pressure gradient, dP, the stroke volume, SV, and the heart frequency, FH, through considerations of momentum conservation across the aortic valve. This leads to a formula consistent with Newton's second law of motion. The form of the new equation is A = (7.5 X 10(-5)) SV FH2/Pd, where A, VS, FH and Pd are expressed in cm2, ml, s-1 and mmHg, respectively. Aortic valve areas computed with the new orifice equation are found to correlate with those computed by the Gorlin formula in conditions of resting haemodynamic states at a level of r = 0.86, SE = 0.25 cm2, N = 120. The results suggest that the new formula may be considered as an independent orifice equation having a similar domain of validity as the Gorlin formula. The new equation offers the possibility of deriving additional useful haemodynamic relationships through combination with established cardiological formulas and applying it in a noninvasive Doppler ultrasonic or echocardiographic context.
Application of active control landing gear technology to the A-10 aircraft
NASA Technical Reports Server (NTRS)
Ross, I.; Edson, R.
1983-01-01
Two concepts which reduce the A-10 aircraft's wing/gear interface forces as a result of applying active control technology to the main landing gear are described. In the first concept, referred to as the alternate concept a servovalve in a closed pressure control loop configuration effectively varies the size of the third stage spool valve orifice which is embedded in the strut. This action allows the internal energy in the strut to shunt hydraulic flow around the metering orifice. The command signal to the loop is reference strut pressure which is compared to the measured strut pressure, the difference being the loop error. Thus, the loop effectively varies the spool valve orifice size to maintain the strut pressure, and therefore minimizes the wing/gear interface force referenced.
Gas arc constriction for plasma arc welding
NASA Technical Reports Server (NTRS)
McGee, William F. (Inventor); Rybicki, Daniel J. (Inventor)
1994-01-01
A welding torch for plasma arc welding apparatus has an inert gas applied circumferentially about the arc column externally of the constricting nozzle so as to apply a constricting force on the arc after it has exited the nozzle orifice and downstream of the auxiliary shielding gas. The constricting inert gas is supplied to a plenum chamber about the body of the torch and exits through a series of circumferentially disposed orifices in an annular wall forming a closure at the forward end of the constricting gas plenum chamber. The constricting force of the circumferential gas flow about the arc concentrates and focuses the arc column into a more narrow and dense column of energy after exiting the nozzle orifice so that the arc better retains its energy density prior to contacting the workpiece.
METHOD OF PRODUCING AND ACCELERATING AN ION BEAM
NASA Technical Reports Server (NTRS)
Foster, John E. (Inventor)
2005-01-01
A method of producing and accelerating an ion beam comprising the steps of providing a magnetic field with a cusp that opens in an outward direction along a centerline that passes through a vertex of the cusp: providing an ionizing gas that sprays outward through at least one capillary-like orifice in a plenum that is positioned such that the orifice is on the centerline in the cusp, outward of the vortex of the cusp; providing a cathode electron source, and positioning it outward of the orifice and off of the centerline; and positively charging the plenum relative to the cathode electron source such that the plenum functions as m anode. A hot filament may be used as the cathode electron source, and permanent magnets may be used to provide the magnetic field.
High-bandwidth continuous-flow arc furnace
Hardt, David E.; Lee, Steven G.
1996-01-01
A high-bandwidth continuous-flow arc furnace for stream welding applications includes a metal mass contained in a crucible having an orifice. A power source charges an electrode for generating an arc between the electrode and the mass. The arc heats the metal mass to a molten state. A pressurized gas source propels the molten metal mass through the crucible orifice in a continuous stream. As the metal is ejected, a metal feeder replenishes the molten metal bath. A control system regulates the electrode current, shielding gas pressure, and metal source to provide a continuous flow of molten metal at the crucible orifice. Independent control over the electrode current and shield gas pressure decouples the metal flow temperature and the molten metal flow rate, improving control over resultant weld characteristics.
High-bandwidth continuous-flow arc furnace
Hardt, D.E.; Lee, S.G.
1996-08-06
A high-bandwidth continuous-flow arc furnace for stream welding applications includes a metal mass contained in a crucible having an orifice. A power source charges an electrode for generating an arc between the electrode and the mass. The arc heats the metal mass to a molten state. A pressurized gas source propels the molten metal mass through the crucible orifice in a continuous stream. As the metal is ejected, a metal feeder replenishes the molten metal bath. A control system regulates the electrode current, shielding gas pressure, and metal source to provide a continuous flow of molten metal at the crucible orifice. Independent control over the electrode current and shield gas pressure decouples the metal flow temperature and the molten metal flow rate, improving control over resultant weld characteristics. 4 figs.
NASA Technical Reports Server (NTRS)
Sivo, Joseph M.; Acosta, A. J.; Brennen, C. E.; Caughey, T. K.
1993-01-01
Recent experiments conducted in the Rotor Force Test Facility at the California Institute of Technology have examined the effects of a tip leakage restriction and swirl brakes on the rotordynamic forces due to leakage flows on an impeller undergoing a prescribed circular whirl. The experiments simulate the leakage flow conditions and geometry of the Alternate Turbopump Design (ATD) of the Space Shuttle High Pressure Oxygen Turbopump and are critical to evaluating the pump's rotordynamic instability problems. Previous experimental and analytical results have shown that discharge-to-suction leakage flows in the annulus of a shrouded centrifugal pump contribute substantially to the fluid induced rotordynamic forces. Also, previous experiments have shown that leakage inlet (pump discharge) swirl can increase the cross-coupled stiffness coefficient and hence increase the range of positive whirl for which the tangential force is destabilizing. In recent experimental work, the present authors demonstrated that when the swirl velocity within the leakage path is reduced by the introduction of ribs or swirl brakes, then a substantial decrease in both the destabilizing normal and tangential forces could be achieved. Motivation for the present research is that previous experiments have shown that restrictions such as wear rings or orifices at pump inlets affect the leakage forces. Recent pump designs such as the Space Shuttle Alternate Turbopump Design (ATD) utilize tip orifices at discharge for the purpose of establishing axial thrust balance. The ATD has experienced rotordynamic instability problems and one may surmise that these tip discharge orifices may also have an important effect on the normal and tangential forces in the plane of impeller rotation. The present study determines if such tip leakage restrictions contribute to undesirable rotordynamic forces. Additional motivation for the present study is that the widening of the leakage path annular clearance and the installation of swirl brakes in the ATD has been proposed to solve its instability problems. The present study assesses the effect of such a design modification on the rotordynamic forces. The experimental apparatus consists of a solid or dummy impeller, a housing instrumented for pressure measurements, a rotating dynamometer and an eccentric whirl mechanism. The solid impeller is used so that leakage flow contributions to the forces are measured, but the main throughflow contributions are not experienced. The inner surface of the housing has been modified to accommodate meridional ribs or swirl brakes within the leakage annulus. In addition, the housing has been modified to accommodate a discharge orifice that qualitatively simulates one side of the balance piston orifice of the Space Shuttle ATD. Results indicate the detrimental effects of a discharge orifice and the beneficial effects of brakes. Plots of the tangential and normal forces versus whirl ratio show a substantial increase in these forces along with destabilizing resonances at some positive whirl ratios when a discharge orifice is added. When brakes are added, some of the detrimental effects of the orifice are reduced. For the tangential force, a plot versus whirl ratio shows a significant reduction and a destabilizing resonance appears to be eliminated. For the normal force, although the overall force is not reduced, again a destabilizing resonance appears to be eliminated.
The triangle of the urinary bladder in American mink (Mustela vision (Brisson, 1756)).
Gościcka, D; Krakowiak, E; Kepczyńska, M
1994-01-01
60 bladders of American minks were dissected according to conventional method. Biometrical analysis with the use of digital image analysis system was applied to the triangles of the bladders. It was found that these triangles differ both in shape (narrow, broad) and symmetry (considerable asymmetry). The ureteral orifices also showed a variety in shape (five types) and number (double orifices).
Christiansen, David W.; Karnesky, Richard A.; Precechtel, Donald R.; Smith, Bob G.; Knight, Ronald C.
1987-01-01
An inlet nozzle assembly for directing coolant into the duct tube of a fuel assembly attached thereto. The nozzle assembly includes a shell for housing separable components including an orifice plate assembly, a neutron shield block, a neutron shield plug, and a diffuser block. The orifice plate assembly includes a plurality of stacked plates of differently configurated and sized openings for directing coolant therethrough in a predesigned flow pattern.
Standards for discharge measurement with standardized nozzles and orifices
NASA Technical Reports Server (NTRS)
1940-01-01
The following standards give the standardized forms for two throttling devices, standard nozzles and standard orifices, and enable them to be used in circular pipes without calibration. The definition of the standards are applicable in principle to the calibration and use of nonstandardized throttling devices, such as the venturi tube. The standards are valid, likewise, as a basis for discharge measurements in the German acceptance standards.
Christiansen, D.W.; Karnesky, R.A.; Knight, R.C.; Precechtel, D.R.; Smith, B.G.
1985-09-09
An inlet nozzle assembly for directing coolant into the duct tube of a fuel assembly attached thereto. The nozzle assembly includes a shell for housing separable components including an orifice plate assembly, a neutron shield block, a neutron shield plug, and a diffuser block. The orifice plate assembly includes a plurality of stacked plates of differently configurated and sized openings for directing coolant therethrough in a predesigned flow pattern.
Thermodynamic and fluid mechanic analysis of rapid pressurization in a dead-end tube
NASA Technical Reports Server (NTRS)
Leslie, Ian H.
1989-01-01
Three models have been applied to very rapid compression of oxygen in a dead-ended tube. Pressures as high as 41 MPa (6000 psi) leading to peak temperatures of 1400 K are predicted. These temperatures are well in excess of the autoignition temperature (750 K) of teflon, a frequently used material for lining hoses employed in oxygen service. These findings are in accord with experiments that have resulted in ignition and combustion of the teflon, leading to the combustion of the stainless steel braiding and catastrophic failure. The system analyzed was representative of a capped off-high-pressure oxygen line, which could be part of a larger system. Pressurization of the larger system would lead to compression in the dead-end line, and possible ignition of the teflon liner. The model consists of a large plenum containing oxygen at the desired pressure (500 to 6000 psi). The plenum is connected via a fast acting valve to a stainless steel tube 2 cm inside diameter. Opening times are on the order of 15 ms. Downstream of the valve is an orifice sized to increase filling times to around 100 ms. The total length from the valve to the dead-end is 150 cm. The distance from the valve to the orifice is 95 cm. The models describe the fluid mechanics and thermodynamics of the flow, and do not include any combustion phenomena. A purely thermodynamic model assumes filling to be complete upstream of the orifice before any gas passes through the orifice. This simplification is reasonable based on experiment and computer modeling. Results show that peak temperatures as high as 4800 K can result from recompression of the gas after expanding through the orifice. An approximate transient model without an orifice was developed assuming an isentropic compression process. An analytical solution was obtained. Results indicated that fill times can be considerably shorter than valve opening times. The third model was a finite difference, 1-D transient compressible flow model. Results from the code show the recompression effect but predict much lower peak temperatures than the thermodynamic model.
Thermodynamic and fluid mechanic analysis of rapid pressurization in a dead-end tube
NASA Astrophysics Data System (ADS)
Leslie, Ian H.
1989-12-01
Three models have been applied to very rapid compression of oxygen in a dead-ended tube. Pressures as high as 41 MPa (6000 psi) leading to peak temperatures of 1400 K are predicted. These temperatures are well in excess of the autoignition temperature (750 K) of teflon, a frequently used material for lining hoses employed in oxygen service. These findings are in accord with experiments that have resulted in ignition and combustion of the teflon, leading to the combustion of the stainless steel braiding and catastrophic failure. The system analyzed was representative of a capped off-high-pressure oxygen line, which could be part of a larger system. Pressurization of the larger system would lead to compression in the dead-end line, and possible ignition of the teflon liner. The model consists of a large plenum containing oxygen at the desired pressure (500 to 6000 psi). The plenum is connected via a fast acting valve to a stainless steel tube 2 cm inside diameter. Opening times are on the order of 15 ms. Downstream of the valve is an orifice sized to increase filling times to around 100 ms. The total length from the valve to the dead-end is 150 cm. The distance from the valve to the orifice is 95 cm. The models describe the fluid mechanics and thermodynamics of the flow, and do not include any combustion phenomena. A purely thermodynamic model assumes filling to be complete upstream of the orifice before any gas passes through the orifice. This simplification is reasonable based on experiment and computer modeling. Results show that peak temperatures as high as 4800 K can result from recompression of the gas after expanding through the orifice. An approximate transient model without an orifice was developed assuming an isentropic compression process. An analytical solution was obtained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Som, S.; Longman, D. E; Ramirez, A. I.
2011-03-01
Diesel engine performance and emissions are strongly coupled with fuel atomization and spray processes, which in turn are strongly influenced by injector flow dynamics. Modern engines employ micro-orifices with different orifice designs. It is critical to characterize the effects of various designs on engine performance and emissions. In this study, a recently developed primary breakup model (KH-ACT), which accounts for the effects of cavitation and turbulence generated inside the injector nozzle is incorporated into a CFD software CONVERGE for comprehensive engine simulations. The effects of orifice geometry on inner nozzle flow, spray, and combustion processes are examined by coupling themore » injector flow and spray simulations. Results indicate that conicity and hydrogrinding reduce cavitation and turbulence inside the nozzle orifice, which slows down primary breakup, increasing spray penetration, and reducing dispersion. Consequently, with conical and hydroground nozzles, the vaporization rate and fuel air mixing are reduced, and ignition occurs further downstream. The flame lift-off lengths are the highest and lowest for the hydroground and conical nozzles, respectively. This can be related to the rate of fuel injection, which is higher for the hydroground nozzle, leading to richer mixtures and lower flame base speeds. A modified flame index is employed to resolve the flame structure, which indicates a dual combustion mode. For the conical nozzle, the relative role of rich premixed combustion is enhanced and that of diffusion combustion reduced compared to the other two nozzles. In contrast, for the hydroground nozzle, the role of rich premixed combustion is reduced and that of non-premixed combustion is enhanced. Consequently, the amount of soot produced is the highest for the conical nozzle, while the amount of NOx produced is the highest for the hydroground nozzle, indicating the classical tradeoff between them.« less
Bubble Formation at a Submerged Orifice in Reduced Gravity
NASA Technical Reports Server (NTRS)
Buyevich, Yu A.; Webbon, Bruce W.
1994-01-01
The dynamic regime of gas injection through a circular plate orifice into an ideally wetting liquid is considered, when successively detached bubbles may be regarded as separate identities. In normal gravity and at relatively low gas flow rates, a growing bubble is modeled as a spherical segment touching the orifice perimeter during the whole time of its evolution. If the flow rate exceeds a certain threshold value, another stage of the detachment process takes place in which an almost spherical gas envelope is connected with the orifice by a nearly cylindrical stem that lengthens as the bubble rises above the plate. The bubble shape resembles then that of a mushroom and the upper envelope continues to grow until the gas supply through the stem is completely cut off. Such a stage is always present under conditions of sufficiently low gravity, irrespective of the flow rate. Two major reasons make for bubble detachment: the buoyancy force and the force due to the momentum inflow into the bubble with the injected gas. The former force dominates the process at normal gravity whereas the second one plays a key role under negligible gravity conditions. It is precisely this fundamental factor that conditions the drastic influence on bubble growth and detachment that changes in gravity are able to cause. The frequency of bubble formation is proportional to and the volume of detached bubbles is independent of the gas flow rate in sufficiently low gravity, while at normal and moderately reduced gravity conditions the first variable slightly decreases and the second one almost linearly increases as the flow rate grows. Effects of other parameters, such as the orifice radius, gas and liquid densities, and surface tension are discussed.
NASA Astrophysics Data System (ADS)
Yao, Hou Chang; Chyan Deng, Jan; Chao, Hsu Yu; Chih Yuan, Yang
2017-04-01
A vortex sediment-extraction chamber, consisted of cylindrical chamber, inflow system, bottom orifice and overflow weir, is used to separate sediment from sediment-laden water flow. A tangential inflow is introduced into a cylindrical chamber with a bottom orifice; thus, a strong vortex flow is produced there. Under actions of gravity and centrifugal force, heavier sediment particles are forced to move towards the bottom orifice, and relatively clear water flows over through the top overflow weir. The flow field in the cylindrical chamber consists of forced vortex and free vortex. When the bottom orifice is opened during the sediment-extraction process, an air core appears and changes with different settings. In this study, the air core and water surface velocity in the cylindrical chamber were measured by using a photo image process and particle tracking velocimetry (PTV), as well as numerically simulated by using a commercial software, Flow-3D.Laboratory experiments were conducted in a vortex chamber, having height of 130 cm and diameter of 48 cm. Five kinds of bottom orifice size from 1.0 cm to 3.0 cm and four kinds of inflow water discharge from 1,300cm3/s to 1,700 cm3/s were used while the inflow pipe of 3 cm in diameter was kept the same for all experiments. The characteristics of the air core and water surface velocity, and the inflow and outflow ratios under different experimental arrangements were observed and discussed so as to provide a better design and application for a vortex sediment-extraction chamber in the future.
Morphometric features of the right atrioventricular orifice in adult human hearts.
Skwarek, M; Hreczecha, J; Dudziak, M; Jerzemowski, J; Szpinda, M; Grzybiak, M
2008-02-01
The normal data of the tricuspid valve complex is of great clinical importance in the light of progress in cardiosurgery and the development of novel operating techniques. A range of measurements for the right atrioventricular orifice in 96 human adult hearts was examined by means of anatomical dissection, inspection, examination, and statistical analyses. The length of the attachment of the anterior leaflet increased significantly between group I (aged 18-40 years) and group II (aged 41-64 years) in women only. In men there were no significant differences in this parameter between any of the three age groups. In addition, the attachment length of the posterior leaflet in women increased statistically in the second age group. In men, in contrast, the attachment length of the posterior leaflet did not increase significantly between the first and second age groups and became significantly larger only in oldest age group, consisting of men aged over 65. No statistically significant differences between the three age groups were found for the attachment length of the septal leaflet (p>0.05). In female hearts significant increases in the frontal and sagittal dimensions of the tricuspid valve orifice were observed between the second age group and the group aged over 65. In male hearts both the frontal and sagittal dimensions increased significantly with advanced age. The right atrioventricular orifice expressed as the ellipse area was statistically greater than the triangular area (p<0.01) in each age group. It should be noticed that both areas increased significantly during ageing. This study has demonstrated that the shape of the right atrioventricular orifice evolves during life, from a triangular shape to a more elliptical shape.
Reappraisal of adhesive strapping as treatment for infantile umbilical hernia.
Yanagisawa, Satohiko; Kato, Mototoshi; Oshio, Takehito; Morikawa, Yasuhide
2016-05-01
Most umbilical hernias spontaneously close by 3-5 years of age; therefore, surgical repair is considered only in children whose hernias have not closed by this point. At present, adhesive strapping is not the preferred treatment for umbilical hernias because of the lack of supporting evidence regarding its efficacy, and its association with skin complications. This aim of this study was to examine umbilical hernia closure on ultrasonography, and reassess the merits of adhesive strapping. Between January 2013 and December 2014, 89 infants underwent adhesive strapping for umbilical hernia. The strapping was changed once a week. The diameter of the hernia orifice was measured on ultrasonography every 2 weeks until closure. The closure speed (CS) of the hernia orifice was compared between the infants treated with adhesive strapping and those undergoing observation alone. The association between CS and birthweight, gestational age, diameter of the hernia orifice, and timing of treatment (before 12 weeks of age vs between 12 and 26 weeks of age) was also analyzed. Closure was achieved after 2-13 weeks of strapping in 81 infants (91%), and the likelihood of closure was not affected by the diameter of the hernia orifice, gestational age, or the timing of treatment. The mean CS of the infants treated with adhesive strapping was significantly faster than that of the infants undergoing observation alone (2.59 vs 0.37 mm/week, P < 0.05). Adhesive strapping was discontinued in five of the 89 infants (5.6%) due to severe skin complications. Adhesive strapping promoted early spontaneous umbilical hernia closure compared with observation alone, regardless of the diameter of the hernia orifice. Adhesive strapping is an effective alternative to surgery and observation. © 2015 Japan Pediatric Society.
Trailing edge cooling using angled impingement on surface enhanced with cast chevron arrangements
Lee, Ching-Pang; Heneveld, Benjamin E.; Brown, Glenn E.; Klinger, Jill
2015-05-26
A gas turbine engine component, including: a pressure side (12) having an interior surface (34); a suction side (14) having an interior surface (36); a trailing edge portion (30); and a plurality of suction side and pressure side impingement orifices (24) disposed in the trailing edge portion (30). Each suction side impingement orifice is configured to direct an impingement jet (48) at an acute angle (52) onto a target area (60) that encompasses a tip (140) of a chevron (122) within a chevron arrangement (120) formed in the suction side interior surface. Each pressure side impingement orifice is configured to direct an impingement jet at an acute angle onto an elongated target area that encompasses a tip of a chevron within a chevron arrangement formed in the pressure side interior surface.
NASA Technical Reports Server (NTRS)
Holderman, James D.; Clisset, James R.; Moder, Jeffrey P.
2010-01-01
This is a printout of the supplemental spreadsheet that is a supplement to the document found in NASA/TM-2010-216100. The calculations for cases of opposed rows of jets with the orifices on one side shifted show that staggering can improve the mixing, particularly for cases where jets would overpenetrate slightly if the orifices were in an aligned configuration.
Transient High-Pressure Fuel Injection Processes
2012-11-21
ADDRESSES U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 15. SUBJECT TERMS Fuel injection, hydrodynamic instability...nonlinear waves resulting from hydrodynamic instability form vortex structures that affect the shear layer near the interface. Pro- trusions (which are...to increase the length of the orifice channel; the orifice channel for case (a) is twice that of (b). The effects of cavitation and flow recirculation
NASA Astrophysics Data System (ADS)
Traeger, Brad; Srivatsa, Sanjay S.; Beussman, Kevin M.; Wang, Yechun; Suzen, Yildirim B.; Rybicki, Frank J.; Mazur, Wojciech; Miszalski-Jamka, Tomasz
2016-04-01
Aortic stenosis is the most common valvular heart disease. Assessing the contribution of the valve as a portion to total ventricular load is essential for the aging population. A CT scan for one patient was used to create one in vivo tricuspid aortic valve geometry and assessed with computational fluid dynamics (CFD). CFD simulated the pressure, velocity, and flow rate, which were used to assess the Gorlin formula and continuity equation, current clinical diagnostic standards. The results demonstrate an underestimation of the anatomic orifice area (AOA) by Gorlin formula and overestimation of AOA by the continuity equation, using peak velocities, as would be measured clinically by Doppler echocardiography. As a result, we suggest that the Gorlin formula is unable to achieve the intended estimation of AOA and largely underestimates AOA at the critical low-flow states present in heart failure. The disparity in the use of echocardiography with the continuity equation is due to the variation in velocity profile between the outflow tract and the valve orifice. Comparison of time-averaged orifice areas by Gorlin and continuity with instantaneous orifice areas by planimetry can mask the errors of these methods, which is a result of the assumption that the blood flow is inviscid.
Chin, Lijin; Moran, Jonathan A; Clarke, Charles
2010-04-01
*Three Bornean pitcher plant species, Nepenthes lowii, N. rajah and N. macrophylla, produce modified pitchers that 'capture' tree shrew faeces for nutritional benefit. Tree shrews (Tupaia montana) feed on exudates produced by glands on the inner surfaces of the pitcher lids and defecate into the pitchers. *Here, we tested the hypothesis that pitcher geometry in these species is related to tree shrew body size by comparing the pitcher characteristics with those of five other 'typical' (arthropod-trapping) Nepenthes species. *We found that only pitchers with large orifices and lids that are concave, elongated and oriented approximately at right angles to the orifice capture faeces. The distance from the tree shrews' food source (that is, the lid nectar glands) to the front of the pitcher orifice precisely matches the head plus body length of T. montana in the faeces-trapping species, and is a function of orifice size and the angle of lid reflexion. *Substantial changes to nutrient acquisition strategies in carnivorous plants may occur through simple modifications to trap geometry. This extraordinary plant-animal interaction adds to a growing body of evidence that Nepenthes represents a candidate model for adaptive radiation with regard to nitrogen sequestration strategies.
Chen, Wei-Liang
2016-12-01
A facial sebaceous cyst is a common benign epithelial tumor and surgical excision is frequently performed but may cause obvious scarring and may be esthetically troubling. This study evaluated the clinical outcomes of the patients with facial sebaceous cyst enucleated by creating minimal elliptical incisions through a keratin-filled orifice. Eleven patients with facial sebaceous cyst enucleated by creating minimal elliptical incisions through a keratin-filled orifice. We treated nine male and two female patients aged 25-52 years. The mean cyst size was 1.85 × 1.56 cm. All cysts were successfully enucleated. The mean wound length was 0.93 cm. The mean operative time was 15.2 min. The mean follow-up duration was 41.5 months. No recurrence was noted, and all patients were very satisfied with their esthetic outcomes. All cysts were successfully enucleated. The mean elliptical wound length was 0.93 cm (range, 0.8-1.1 cm). The mean operative time was 15.2 min. We found no evidence of wound infection, or nerve or vascular injury. Enucleation of facial sebaceous cyst via a minimal elliptical incision through the keratin-filled orifice was associated with high-level patient satisfaction, and the method is safe and useful for treating facial epidermoid cysts. © 2016 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young Il; Chung, Jin Wook, E-mail: chungjw@snu.ac.kr; Kim, Hyun Beom
PurposeThis study was designed to investigate the effects of stenting across the branching arteries on the patency and stent-tissue responses over the branching arterial orifices. Methods: Thirteen dogs were observed after placing aortic stents across the celiac arteries (CA), superior mesenteric arteries (SMA), and renal arteries (RA). The animals were grouped according to stent types: large-cell group (n = 6) and small-cell group (n = 7). Angiography was performed to evaluate the branching artery patency at 2, 6, and 12 months after stent insertion, and the stent-tissue responses covering the orifices were evaluated on histopathologic examination. Results: All branching arteriesmore » were patent on follow-up angiography; however, three patterns of stent-tissue responses over the orifices were observed: neointimal layering, bridging septa, and papillary hyperplasia. Although neointimal layering and bridging septa were evenly observed, severe papillary hyperplasia was more frequent at SMA and CA than RA. Four RA showed less than 50% ostial patency, and localized infarct was observed in six kidneys (24%). The ostial patency tended to decrease with small-cell stent during the follow-up period. Conclusions: Various stent-tissue responses over the branching artery orifices are induced by the aortic stent covering the branching arteries and may not be easily detected by conventional angiography. Subclinical renal infarct also may occur despite patent renal angiography.« less
Coefficients of discharge of fuel-injection nozzles for compression-ignition engines
NASA Technical Reports Server (NTRS)
Gelalles, A G
1932-01-01
This report presents the results of an investigation to determine the coefficients of discharge of nozzles with small, round orifices of the size used with high-speed compression-ignition engines. The injection pressures and chamber back pressures employed were comparable to those existing in compression-ignition engines during injection. The construction of the nozzles was varied to determine the effect of the nozzle design on the coefficient. Tests were also made with nozzles assembled in an automatic injection valve, both with a plain and with a helically grooved stem. It was found that a smooth passage before the orifice is requisite for high flow efficiency. A beveled leading edge before the orifice gave a higher coefficient of discharge than a rounded edge. The results with the nozzles assembled in an automatic injection valve having a plain stem duplicated those with the nozzles assembled at the end of a straight tube of constant diameter. Lower coefficients were obtained with the nozzles assembled in an injection valve having a helically grooved stem. When the coefficients of nozzles of any one geometrical shape were plotted against values of corresponding Reynold's numbers for the orifice diameters and rates of flow tested, it was found that experimental points were distributed along a single curve.
Seitz, W; Marino, P; Zanolla, L; Buonanno, C; McIlroy, M; Spiel, M
1984-11-01
An orifice equation is developed which relates the effective mitral valve area (A), the average mitral valve pressure gradient (dP), the cardiac output (Q) and the heart frequency (f) through considerations of momentum conservation across the mitral valve. The form of the new equation is A = (4.75 X 10(-5)Qf/dP, where A, Q, and dP are expressed in cm2, ml X min-1 and mmHg respectively. Mitral valve areas computed with the new orifice formula are found to correlate with those computed by the Gorlin formula in conditions of equilibrium associated with the resting state at a level of r = 0.95, SE = 0.15 cm2, with autopsy measurements at a level of r = 0.85, SE = 0.18 cm2 and with direct anatomical measurements of excised valves at a level of r = 0.78, SE = 0.41 cm2. The results suggest that the new formula may be considered as an independent orifice equation enjoying a similar domain of validity as the Gorlin formula. The new equation offers the possibility of deriving additional useful haemodynamic relationships when used in combination with established cardiological formulas.
Prevalence of Three-Rooted Mandibular First Molars among Indians Using SCT
Garg, Amit Kumar; Tewari, Rajendra Kumar; Agrawal, Neha
2013-01-01
Undetected extra roots or root canals are a major reason for failure of endodontic treatment. Failure to recognize an extra distolingual (DL) root in mandibular first molar may lead to incomplete debridement of the root canal system and eventually treatment failure. Therefore, it is crucial that atypical anatomy is identified before and during dental treatment. Spiral computed tomography (SCT) images can show 3D images, and therefore much detail can be used when traditional methods prevent adequate endodontic treatment. The overall incidence of DL roots on the mandibular first molars was 6.40% for all patients and 5.00% for all teeth, respectively. The occurrence of DL roots on the right side and on the left side showed a statistically significant difference. The bilateral incidence of symmetrical distribution of DL roots was 56.25%. The DL root canal orifice was separated from DB canal orifice by 2.79 ± 0.34 mm, from the MB canal orifice by 4.23 ± 0.81 mm, and from the ML canal orifice by 3.29 ± 0.52 mm. The high prevalence of the DL root in permanent mandibular first molars among the Indian population by using SCT and estimations of the interorifice distance of such teeth might be useful for successful endodontic treatments. PMID:23840212
PLIF Visualization of Active Control of Hypersonic Boundary Layers Using Blowing
NASA Technical Reports Server (NTRS)
Bathel, Brett F.; Danehy, Paul M.; Inman, Jennifer A.; Alderfer, David W.; Berry, Scott A.
2008-01-01
Planar laser-induced fluorescence (PLIF) imaging was used to visualize the boundary layer flow on a 1/3-scale Hyper-X forebody model. The boundary layer was perturbed by blowing out of orifices normal to the model surface. Two blowing orifice configurations were used: a spanwise row of 17-holes spaced at 1/8 inch, with diameters of 0.020 inches and a single-hole orifice with a diameter of 0.010 inches. The purpose of the study was to visualize and identify laminar and turbulent structures in the boundary layer and to make comparisons with previous phosphor thermography measurements of surface heating. Jet penetration and its influence on the boundary layer development was also examined as was the effect of a compression corner on downstream boundary layer transition. Based upon the acquired PLIF images, it was determined that global surface heating measurements obtained using the phosphor thermography technique provide an incomplete indicator of transitional and turbulent behavior of the corresponding boundary layer flow. Additionally, the PLIF images show a significant contribution towards transition from instabilities originating from the underexpanded jets. For this experiment, a nitric oxide/nitrogen mixture was seeded through the orifices, with nitric oxide (NO) serving as the fluorescing gas. The experiment was performed in the 31-inch Mach 10 Air Tunnel at NASA Langley Research Center.
Method for generating small and ultra small apertures, slits, nozzles and orifices
Khounsary, Ali M [Hinsdale, IL
2012-05-22
A method and device for one or more small apertures, slits, nozzles and orifices, preferably having a high aspect ratio. In one embodiment, one or more alternating layers of sacrificial layers and blocking layers are deposited onto a substrate. Each sacrificial layer is made of a material which preferably allows a radiation to substantially pass through. Each blocking layer is made of a material which substantially blocks the radiation.
Booth, Rex
1994-01-01
A planar triode is mounted in a PC board orifice by means of a U-shaped capacitor housing and anode contact yoke removably attached to cathode leg extensions passing through and soldered to the cathode side of the PC board by means of a PC cathode pad. A pliant/flexible contact attached to the orifice make triode grid contact with a grid pad on the grid side of the PC board, permitting quick and easy replacement of bad triodes.
Modifications Of A Commercial Spray Gun
NASA Technical Reports Server (NTRS)
Allen, Peter B.
1993-01-01
Commercial spray gun modified to increase spray rate and make sprayed coats more nearly uniform. Consists of gun head and pneumatic actuator. Actuator opens valves for two chemical components, called "A" and "B," that react to produce foam. Components flow through orifices, into mixing chamber in head. Mixture then flows through control orifice to spray tip. New spray tip tapered to reduce area available for accumulation of foam and makes tip easier to clean.
Screw-Thread Inserts As Temporary Flow Restrictors
NASA Technical Reports Server (NTRS)
Trimarchi, Paul
1992-01-01
Coil-spring screw-thread inserts found useful as temporary flow restrictors. Inserts placed in holes through which flow restricted, effectively reducing cross sections available for flow. Friction alone holds inserts against moderate upstream pressures. Use of coil-spring thread inserts as flow restrictors conceived as inexpensive solution to problem of adjusting flow of oxygen through orifices in faceplate into hydrogen/oxygen combustion chamber. Installation and removal of threaded inserts gentle enough not to deform orifice tubes.
Ting, Jason; Anderson, Iver E.; Terpstra, Robert L.
2000-03-16
A high pressure close-coupled gas atomizing nozzle includes multiple discrete gas jet discharge orifices having aerodynamically designed convergent-divergent geometry with an first converging section communicated to a gas supply manifold and to a diverging section by a constricted throat section to increase atomizing gas velocity. The gas jet orifices are oriented at gas jet apex angle selected relative to the melt supply tip apex angle to establish a melt aspiration condition at the melt supply tip.
Experimental and numerical research of synthetic jet array
NASA Astrophysics Data System (ADS)
Dančová, Petra; Novosád, Jan; Vít, Tomáš; Trávníček, Zdeněk
2016-03-01
This paper describes the additional research of the synthetic jet array in a channel flow and continues the paper of authors Dančová, Trávníček and Vít, [1]. Numerical simulations support the experiments from [1] and the influence of the new slope of the synthetic jet orifices is studied here. This research will be used for preparation of the experiments with inclined orifices of the synthetic jet array.
Electrical Counting and Sizing of Mammalian Cells in Suspension
Gregg, E. C.; Steidley, K. David
1965-01-01
A recently developed method of determining the number and size of particles suspended in a conducting solution is to pump the suspension through a small orifice having an immersed electrode on each side to supply electrical current. The current changes due to the passage of particles of resistivity different from that of the solution. Theoretical expressions are developed which relate the current change caused by such particles to their volume and shape. It is found that most biological cells may be treated as dielectric particles whose capacitive effects are negligible. Electrolytic tank measurements on models confirm the theoretical development, and electric field plots of model orifices are used to predict the observed pulse shapes. An equivalent circuit of the orifice-electrode system is analyzed and shows that the current pulse may be made conductivity-independent when observed with a zero input impedance amplifier. PMID:5861698
Argon hollow cathode. M.S. Thesis; [propellants for ion bombardment thrusters
NASA Technical Reports Server (NTRS)
Rehn, L. A.
1976-01-01
An interest in alternate propellants for ion-bombardment thrusters, together with ground applications of this technology, has prompted consideration of argon. Several variations of conventional hollow cathode designs were tried, but the bulk of the testing used a hollow tube with an internal tungsten emitter and an orifice at one end. The optimum cathode tube diameter was found to be in the range of 1.0-2.5 cm, somewhat larger than those used for cesium and mercury. Optimum orifice diameter depended on operating conditions, and varied from 0.5 to 5 mm. Biasing the internal emitter negative relative to the cathode chamber reduced the external coupling voltage and should therefore improve orifice lifetime. The expected effect of this bias on emitter lifetime was less clear. Lifetime tests were not conducted as part of this investigation, but several designs show promise of long lifetime in specific applications.
NASA Technical Reports Server (NTRS)
Ingebo, R. D.; Norgren, C. T.
1975-01-01
Air-atomizing, splash-groove injectors were shown to improve primary-zone fuel spreading and reduce combustor exhaust emissions for Jet A and diesel number 2 fuels. With Jet A fuel large-orifice, splash-groove injectors the oxides-of-nitrogen emission index was reduced, but emissions of carbon monoxide, unburned hydrocarbons, or smoke were unaffected. Small-orifice, splash-groove injectors did not reduce oxides of nitrogen, but reduced the smoke number and carbon monoxide and unburned-hydrocarbon emission indices. With diesel number 2 fuel, the small-orifice, splash-groove injectors reduced oxides of nitrogen by 19 percent, smoke number by 28 percent, carbon monoxide by 75 percent, and unburned hydrocarbons by 50 percent. Smoke number and unburned hydrocarbons were twice as high with diesel number 2 as with Jet A fuel. Combustor blowout limits were similar for diesel number 2 and Jet A fuels.
Operating limitations of high speed jet lubricated ball bearings
NASA Technical Reports Server (NTRS)
Zaretsky, E. V.; Signer, H.; Bamberger, E. N.
1975-01-01
A parametric study was performed with 120-mm bore angular-contact ball bearings having a nominal contact angle of 20 degrees. The bearings had either an inner- or an outer-race land riding cage, and lubrication was by recirculating oil jets which had either a single or dual orifice. Thrust load, speed, and lubricant flow rate were varied. Test results were compared with those previously reported and obtained from bearings of the same design which were under-race lubricated but run under the same conditions. Jet lubricated ball bearings were limited to speeds less than 2,500,000 DN, and bearings having inner-race land riding cages produced lower temperatures than bearings with outer-race land riding cages. For a given lubricant flow rate dual orifice jets produced lower bearing temperatures than single orifice jets, but under-race lubrication produced lower bearing temperatures under all conditions of operation with no apparent bearing speed limitation.
Natural-orifice translumenal endoscopic surgery (NOTES): minimally invasive evolution or revolution?
Mohan, Helen M; O'Riordan, James M; Winter, Desmond C
2013-06-01
Since the first animal experimental laparoscopy in 1902, minimal access techniques have revolutionized surgery. Using the natural orifice dates back to at least the second century when Soranus performed a vaginal hysterectomy. The main difference between traditional endolumenal surgery and the translumenal approach of natural-orifice translumenal endoscopic surgery (NOTES) is the intentional puncture of a healthy organ in NOTES to access a cavity or other organ. The aim of this review was to examine the past, present, and potential future role of NOTES in the context of other developments in minimal access surgery. NOTES is at an early stage in its development and a convincing benefit over laparoscopy has not been demonstrated. Concerns regarding complications, for example of viscerotomy closure, have limited the widespread uptake of pure NOTES. However, it is likely that technological advances for NOTES surgery will enhance conventional laparoscopic and endoscopic techniques.
Chen, Tien-En; Kwon, Susan H; Enriquez-Sarano, Maurice; Wong, Benjamin F; Mankad, Sunil V
2013-10-01
Three-dimensional (3D) color Doppler echocardiography (CDE) provides directly measured vena contracta area (VCA). However, a large comprehensive 3D color Doppler echocardiographic study with sufficiently severe tricuspid regurgitation (TR) to verify its value in determining TR severity in comparison with conventional quantitative and semiquantitative two-dimensional (2D) parameters has not been previously conducted. The aim of this study was to examine the utility and feasibility of directly measured VCA by 3D transthoracic CDE, its correlation with 2D echocardiographic measurements of TR, and its ability to determine severe TR. Ninety-two patients with mild or greater TR prospectively underwent 2D and 3D transthoracic echocardiography. Two-dimensional evaluation of TR severity included the ratio of jet area to right atrial area, vena contracta width, and quantification of effective regurgitant orifice area using the flow convergence method. Full-volume breath-hold 3D color data sets of TR were obtained using a real-time 3D echocardiography system. VCA was directly measured by 3D-guided direct planimetry of the color jet. Subgroup analysis included the presence of a pacemaker, eccentricity of the TR jet, ellipticity of the orifice shape, underlying TR mechanism, and baseline rhythm. Three-dimensional VCA correlated well with effective regurgitant orifice area (r = 0.62, P < .0001), moderately with vena contracta width (r = 0.42, P < .0001), and weakly with jet area/right atrial area ratio. Subgroup analysis comparing 3D VCA with 2D effective regurgitant orifice area demonstrated excellent correlation for organic TR (r = 0.86, P < .0001), regular rhythm (r = 0.78, P < .0001), and circular orifice (r = 0.72, P < .0001) but poor correlation in atrial fibrillation rhythm (r = 0.23, P = .0033). Receiver operating characteristic curve analysis for 3D VCA demonstrated good accuracy for severe TR determination. Three-dimensional VCA measurement is feasible and obtainable in the majority of patients with mild or greater TR. Three-dimensional VCA measurement is also feasible in patients with atrial fibrillation but performed poorly even with <20% cycle length variation. Three-dimensional VCA has good cutoff accuracy in determining severe TR. This simple, straightforward 3D color Doppler measurement shows promise as an alternative for the quantification of TR. Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Seaman, Clara; Akingba, A George; Sucosky, Philippe
2014-04-01
The bicuspid aortic valve (BAV), which forms with two leaflets instead of three as in the normal tricuspid aortic valve (TAV), is associated with a spectrum of secondary valvulopathies and aortopathies potentially triggered by hemodynamic abnormalities. While studies have demonstrated an intrinsic degree of stenosis and the existence of a skewed orifice jet in the BAV, the impact of those abnormalities on BAV hemodynamic performance and energy loss has not been examined. This steady-flow study presents the comparative in vitro assessment of the flow field and energy loss in a TAV and type-I BAV under normal and simulated calcified states. Particle-image velocimetry (PIV) measurements were performed to quantify velocity, vorticity, viscous, and Reynolds shear stress fields in normal and simulated calcified porcine TAV and BAV models at six flow rates spanning the systolic phase. The BAV model was created by suturing the two coronary leaflets of a porcine TAV. Calcification was simulated via deposition of glue beads in the base of the leaflets. Valvular performance was characterized in terms of geometric orifice area (GOA), pressure drop, effective orifice area (EOA), energy loss (EL), and energy loss index (ELI). The BAV generated an elliptical orifice and a jet skewed toward the noncoronary leaflet. In contrast, the TAV featured a circular orifice and a jet aligned along the valve long axis. While the BAV exhibited an intrinsic degree of stenosis (18% increase in maximum jet velocity and 7% decrease in EOA relative to the TAV at the maximum flow rate), it generated only a 3% increase in EL and its average ELI (2.10 cm2/m2) remained above the clinical threshold characterizing severe aortic stenosis. The presence of simulated calcific lesions normalized the alignment of the BAV jet and resulted in the loss of jet axisymmetry in the TAV. It also amplified the degree of stenosis in the TAV and BAV, as indicated by the 342% and 404% increase in EL, 70% and 51% reduction in ELI and 48% and 51% decrease in EOA, respectively, relative to the nontreated valve models at the maximum flow rate. This study indicates the ability of the BAV to function as a TAV despite its intrinsic degree of stenosis and suggests the weak dependence of pressure drop on orifice area in calcified valves.
Calibrating the Helium Pressurization System for the Space Shuttle Liquid-Hydrogen Tank
NASA Technical Reports Server (NTRS)
2008-01-01
Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.
Drop interaction with solid boundaries in liquid/liquid systems
NASA Astrophysics Data System (ADS)
Bordoloi, Ankur Deep
The present experimental work was motivated primarily by the CO 2 sequestration process. In a possible scenario during this process, gravity driven CO2 bubbles coalesce at an interface near the rock surface. In another scenario, trapped CO2 fluid may escape from a porous matrix overcoming interfacial force inside a pore. Based on these potential scenarios, the current research was divided into two broad experimental studies. In the first part, coalescence at a quiescent interface of two analogous fluids (silicone oil and water/glycerin mixture) was investigated for water/glycerin drops with Bond number (Bo) ~7 and Ohnesorge number ~ 0.01 using high-speed imaging and time-resolved tomographic PIV. Two perturbation cases with a solid particle wetted in oil and water/glycerin placed adjacent to the coalescing drop were considered. The results were compared with coalescence of a single drop and that of a drop neighBored by a second drop of equivalent size. Each perturbing object caused an initial tilting of the drop, influencing its rupture location, subsequent film retraction and eventual collapse behavior. Once tilted, drops typically ruptured near their lowest vertical position which was located either toward or away from the perturbing object depending on the case. The trends in local retraction speed of the ruptured film and the overall dynamics of the collapsing drops were discussed in detail. In the second part, the motion of gravity driven drops (B o~0.8-11) through a confining orifice d/D<1) was studied using high speed imaging and planar PIV. Drops of water/glycerin, surrounded by silicone oil, fall toward and encounter the orifice plate after reaching terminal speed. The effects of surface wettability were investigated for Both round-edged and sharp-edged orifices. For the round-edged case, a thin film of surrounding oil prevented the drop fluid from contacting the orifice surface, such that the flow outcomes of the drops were independent of surface wettability. For d/D<0.8, the Boundary between drop capture and release depended on a modified Bond number relating drop gravitational time scale to orifice surface tension time scale. For the sharp-edged case, contact was initiated at the orifice edge immediately upon impact, such that surface wettability influenced the drop outcome.
[Treatment of cardiospasm using cardiodilatation technique].
Shevchenko, A N
2007-01-01
139 patients with achalasia of cardiac orifice among which two third were women and one third--men aged 20-65 years have been observed. 97 patients (69.7%) were treated by cardiodilatation. 17 patients (22.3%) of the main group were treated with pneumocardiodilatation. 44 patients (57.3%) underwent cardiodilatation with the help of pneumo-cardiodilatator improved by the author and electrostimulation. Cardiodilatation technique in a complex treatment of achalasia of cardiac orifice was substantiated by the author.
Measurement of Droplet Sizes by the Diffraction Ring Method
1948-07-27
for measuring the droplet size distribution in sprays ob- tained by pressure injection of a liquid through an orifice «roby air- stream atomization...Diameter vs Injection Pressure 10 6. Distribution Curves for Spray Sample of Water Injected into Air Stream .... 11 Page ii Page Hi i^ujJa-je jii...tion in sprays obtained by pressure injection of a liquid through an orifice or by air- stream atomization. Perhaps the most widely used method
In Situ Soil Venting - Full Scale Test, Hill AFB, Guidance Document. Volume 2
1991-08-01
oxidizer. Another system was connected to the existing air scrubber of a building (Reference 23). The self-contained unit reported by Rippberger...devices on the market for flow rate measurement. Some of the more common devices are orifice meters, venturi meters, rotameters, pitot tubes, hot-wire...Notes on how to size and construct orifice meters can be found in Reference 41. * Venturi Meter - A venturi meter works basically on the same
Booth, R.
1994-10-25
A planar triode is mounted in a PC board orifice by means of a U-shaped capacitor housing and anode contact yoke removably attached to cathode leg extensions passing through and soldered to the cathode side of the PC board by means of a PC cathode pad. A pliant/flexible contact attached to the orifice make triode grid contact with a grid pad on the grid side of the PC board, permitting quick and easy replacement of bad triodes. 14 figs.
Fluid manifold design for a solar energy storage tank
NASA Technical Reports Server (NTRS)
Humphries, W. R.; Hewitt, H. C.; Griggs, E. I.
1975-01-01
A design technique for a fluid manifold for use in a solar energy storage tank is given. This analytical treatment generalizes the fluid equations pertinent to manifold design, giving manifold pressures, velocities, and orifice pressure differentials in terms of appropriate fluid and manifold geometry parameters. Experimental results used to corroborate analytical predictions are presented. These data indicate that variations in discharge coefficients due to variations in orifices can cause deviations between analytical predictions and actual performance values.
The effect of non-zero radial velocity on the impulse and circulation of starting jets
NASA Astrophysics Data System (ADS)
Krieg, Michael; Mohseni, Kamran
2011-11-01
Vortex ring formation dynamics are generally studied using two basic types of vortex generators. Piston cylinder vortex generators eject fluid through a long tube which ensures a purely axial jet; whereas, vortex ring generators which expel fluid through a flat plate with a circular orifice produce 2-D jets (non-zero radial velocity). At the nozzle exit plane of the orifice type vortex generator the radial component of velocity is linearly proportional to the radial distance from the axis of symmetry, reaching a maximum at the edge of the orifice with a magnitude around 10 % of the piston velocity (the ratio of the volume flux and the nozzle area). As the jet advances downstream the radial velocity quickly dissipates, and becomes purely axial less than a diameter away from the nozzle exit plane. The radial velocity gradient in the axial direction plays a key role in the rate at which circulation and impulse are ejected from the vortex generator. Though the radial component of velocity is small compared to the axial velocity, it has a significant effect on both the circulation and impulse of the starting jet because of this gradient. The extent of circulation and impulse enhancement is investigated through experimental DPIV data showing that the orifice device produces nearly double both circulation and energy (with identical piston velocity and stroke ratios).
Vortex dynamics of very low aspect ratio rectangular orifice synthetic jets
NASA Astrophysics Data System (ADS)
Straccia, Joseph; Farnsworth, John; Experimental Aerodynamics Laboratory Team
2017-11-01
The vast majority of prior synthetic jet research has focused on actuators with either circular orifices or rectangular orifices with high aspect ratios (AR), i.e. AR >=25. The results reported in these studies have also been biased towards bulk and time averaged statistics of the jet, viewing them in a steady sense as a source of momentum addition. Recent work has revealed that the unsteady vortex dynamics in a synthetic jet can be very relevant to how the jet interacts with and influences the base flow. In this study the synthetic jet issued into a quiescent fluid by an actuator with low orifice aspect ratios (i.e. AR =2-18) was studied using Stereoscopic Particle Image Velocimetry (SPIV) with a special focus on the vortex dynamics. The progression of vortex ring axis switching is presented and a distinct difference between the axis switching dynamics of very low AR (AR <=6) and moderate AR (AR =6-24) vortex rings is discussed. The high resolution SPIV vector fields are also used to extract details of the vortex core structure which are compared to theoretical vortex models. Furthermore, the influence of axis switching on the circulation magnitude around the vortex ring is reported in addition to how circulation varies with time as the ring advects. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship Program under Grant No. (DGE 1144083).
NASA Technical Reports Server (NTRS)
Samuelsen, G. S.; Sowa, W. A.; Hatch, M. S.
1996-01-01
A series of non-reacting parametric experiments was conducted to investigate the effect of geometric and flow variations on mixing of cold jets in an axis-symmetric, heated cross flow. The confined, cylindrical geometries tested represent the quick mix region of a Rich-Burn/Quick-Mix/Lean-Burn (RQL) combustor. The experiments show that orifice geometry and jet to mainstream momentum-flux ratio significantly impact the mixing characteristic of jets in a cylindrical cross stream. A computational code was used to extrapolate the results of the non-reacting experiments to reacting conditions in order to examine the nitric oxide (NO) formation potential of the configurations examined. The results show that the rate of NO formation is highest immediately downstream of the injection plane. For a given momentum-flux ratio, the orifice geometry that mixes effectively in both the immediate vicinity of the injection plane, and in the wall regions at downstream locations, has the potential to produce the lowest NO emissions. The results suggest that further study may not necessarily lead to a universal guideline for designing a low NO mixer. Instead, an assessment of each application may be required to determine the optimum combination of momentum-flux ratio and orifice geometry to minimize NO formation. Experiments at reacting conditions are needed to verify the present results.
Quantification of the transient mass flow rate in a simplex swirl injector
NASA Astrophysics Data System (ADS)
Khil, Taeock; Kim, Sunghyuk; Cho, Seongho; Yoon, Youngbin
2009-07-01
When a heat release and acoustic pressure fluctuations are generated in a combustor by irregular and local combustions, these fluctuations affect the mass flow rate of the propellants injected through the injectors. In addition, variations of the mass flow rate caused by these fluctuations bring about irregular combustion, which is associated with combustion instability, so it is very important to identify a mass variation through the pressure fluctuation on the injector and to investigate its transfer function. Therefore, quantification of the variation of the mass flow rate generated in a simplex swirl injector via the injection pressure fluctuation was the subject of an initial study. To acquire the transient mass flow rate in the orifice with time, the axial velocity of flows and the liquid film thickness in the orifice were measured. The axial velocity was acquired through a theoretical approach after measuring the pressure in the orifice. In an effort to understand the flow area in the orifice, the liquid film thickness was measured by an electric conductance method. In the results, the mass flow rate calculated from the axial velocity and the liquid film thickness measured by the electric conductance method in the orifice was in good agreement with the mass flow rate acquired by the direct measuring method in a small error range within 1% in the steady state and within 4% for the average mass flow rate in a pulsated state. Also, the amplitude (gain) of the mass flow rate acquired by the proposed direct measuring method was confirmed using the PLLIF technique in the low pressure fluctuation frequency ranges with an error under 6%. This study shows that our proposed method can be used to measure the mass flow rate not only in the steady state but also in the unsteady state (or the pulsated state). Moreover, this method shows very high accuracy based on the experimental results.
NASA Astrophysics Data System (ADS)
Mishra, Chandan; Peles, Yoav
2005-11-01
Multifarious hydrodynamic cavitating flow patterns have been detected in the flow of de-ionized water through a 40.5μm wide and 100.8μm deep rectangular slot micro-orifice established inside a 202.6μm wide and 20 000μm long microchannel. This article presents and discusses the flow patterns observed at various stages of cavitation in the aforementioned micrometer-sized silicon device. Cavitation inception occurs with the appearance of inchoate bubbles that emerge from two thin vapor cavities that emanate from the boundaries of the constriction element. A reduction in the cavitation number beyond inception results in the development of twin coherent unsteady large vapor cavities, which appear just downstream of the micro-orifice and engulf the liquid jet. The shedding of both spherical and nonspherical vapor bubbles and their subsequent collapse into vapor plumes downstream of the orifice occurs intermittently. A further reduction in the exit pressure only aids in the elongation of the two coherent cavities and produces two stable vapor pockets. Additionally, interference fringes are clearly observed, showing that the vapor pocket has a curved interface with liquid. At low cavitation numbers, the flow undergoes a flip downstream and the two vapor pockets coalesce and form a single vapor pocket that is encircled by the liquid and extends until the exit of the microchannel. The cavitating flow patterns are unique and are markedly different from those reported for their macroworld counterparts. Evidence of pitting due to cavitation has been observed on the silicon just downstream of the micro-orifice. It is therefore apparent that cavitation will continue to influence/impact the design of high-speed MEMS hydraulic machines, and the pernicious effects of cavitation in terms of erosion, choking, and a reduction in performance will persist in microfluidic systems if apposite hydrodynamic conditions develop.
Experimental Evaluation of an Isolated Synthetic Jet IN Crossflow
NASA Technical Reports Server (NTRS)
Schaeffler, Norman W.; Jenkins, Luther N.; Hepner, Timothy E.
2007-01-01
The second case for this workshop builds upon the isolated synthetic jet of Case 1 by adding a crossflow, with no streamwise pressure gradient, for the developing jet to interact with. Formally, Case 2 examines the interaction of a single, isolated, synthetic jet and a fully turbulent zero-pressure gradient boundary layer. The resulting flow has many of the characteristics that need to be modeled with fidelity if the results of the calculations are to serve as the basis for research and design with active flow control devices. These include the turbulence in the boundary layer, the time-evolution of the large vortical structure emanating from the jet orifice and its subsequent interaction with and distortion by the boundary layer turbulence, and the effect of the suction cycle on the boundary layer flow. In a synthetic jet, the flow through the orifice and out into the outer flowfield alternates between an exhaust and a suction cycle, driven by the contraction and expansion of a cavity internal to the actuator. In the present experiment, the volume changes in the internal cavity are accomplished by replacing one of the rigid walls of the cavity, the wall opposite the orifice exit, with a deformable wall. This flexible wall is driven by a bottom-mounted moveable piston. The piston is driven electro-mechanically. The synthetic jet issues into the external flow through a circular orifice. In the present experiment, this orifice has a diameter of 0.250 inches (6.35 mm). The flow is conceptually similar to that documented in Schaeffler [1]. To document the flow, several measurement techniques were utilized. The upstream boundary conditions (in-flow conditions), and several key phase-averaged velocity profiles were measured with a 3-component laser-Doppler velocimetry system. Phase-averaged velocity field measurements were made with both stereo digital particle image velocimetry and 2-D digital particle image velocimetry as the primary measurement system. Surface pressure measurements were made utilizing an electronically scanned pressure system.
Volpe, V; Brunetti, B; Gigli, G; Lapi, A; Vecchio Ciprioti, S; Ciccioli, A
2017-11-16
The evaporation/decomposition behavior of the imidazolium ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (BMImPF 6 ) was investigated in the overall temperature range 425-551 K by means of the molecular-effusion-based techniques Knudsen effusion mass loss (KEML) and Knudsen effusion mass spectrometry (KEMS), using effusion orifices of different size (from 0.2 to 3 mm in diameter). Specific effusion fluxes measured by KEML were found to depend markedly on the orifice size, suggesting the occurrence of a kinetically delayed evaporation/decomposition process. KEMS experiments revealed that other species are present in the vapor phase besides the intact ion pair BMImPF 6 (g) produced by the simple evaporation BMImPF 6 (l) = BMImPF 6 (g), with relative abundances depending on the orifice size-the larger the orifice, the larger the contribution of the BMImPF 6 (g) species. By combining KEML and KEMS results, the conclusion is drawn that in the investigated temperature range, when small effusion orifices are used, a significant part of the mass loss/volatility of BMImPF 6 is due to molecular products formed by decomposition/dissociation processes rather than to evaporated intact ion pairs. Additional experiments performed by nonisothermal thermogravimetry-differential thermal analysis (TG-DTA) further support the evidence of simultaneous evaporation/decomposition, although the conventional decomposition temperature derived from TG curves is much higher than the temperatures covered in effusion experiments. Partial pressures of the BMImPF 6 (g) species were derived from KEMS spectra and analyzed by second- and third-law methods giving a value of Δ evap H 298K ° = 145.3 ± 2.9 kJ·mol -1 for the standard evaporation enthalpy of BMImPF 6 . A comparison is done with the behavior of the 1-butyl-3-methylimidazolium bis(trifluoromethyl)sulfonylimide (BMImNTf 2 ) ionic liquid.
Detailed Analysis and Design Review of the MARK IX (Modified) Underwater Breathing Apparatus
1969-07-30
hard- chrome plated, and the purge-valve assembly and regulator piston . electroless-nickel plated. Manufacturing/Assembly Controls and Tests The control...high a flow through the orifice, peak pressures of 4500 psi have been applied repeatedly with- out failure or damage to any component. (7) Orifice...c) Proved In use. (d) "Functional" test by stpplkir. (5)J (e) Peak pressure of only 4500 jsi reached. (1) (f) Leak test at 1-1/2 •is. (g) Predive
Perspectives on dilution jet mixing
NASA Technical Reports Server (NTRS)
Holdeman, J. D.
1986-01-01
A microcomputer code which displays 3-D oblique and 2-D plots of the temperature distribution downstream of jets mixing with a confined crossflow has been used to investigate the effects of varying the several independent flow and geometric parameters on the mixing. Temperature profiles calculated with this empirical model are presented to show the effects of orifice size and spacing, momentum flux ratio, density ratio, variable temperature mainstream, flow area convergence, orifice aspect ratio, and opposed and axially staged rows of jets.
Combustion Dynamics Behavior in a Single-Element Lean Direct Injection (LDI) Gas Turbine Combustor
2014-06-01
Constant mass inflow from a choked orifice Exit Boundary Condition Choked nozzle Diameter of combustor 50.8 mm Diameter of air plenum 25.4 mm A...schematic of the LDI combustor is shown in Fig. 1. It comprises an air inlet section, air plenum, swirler- venturi- injector assembly, combustion chamber...and exit nozzle . Air, heated with an 80 kW electrical heater, enters the combustor through a slotted choked orifice plate, designed to minimize
Meyer, J. E.; Schulz, G. E.
1997-01-01
The crystal structure of the maltodextrin-specific porin from Salmonella typhimurium ligated with a maltotrioside at the pore eyelet is known at 2.4 A resolution. The three glucose units assume a conformation close to the natural amylose helix. The pore eyelet fits exactly the cross-section of a maltooligosaccharide chain and thus functions as a constraining orifice. The oligomer permeates the membrane by screwing along the amylose helix through this orifice. Because each glucose glides along the given helix, its interactions can be sampled at any point along the pathway. The interactions are mostly hydrogen bonds, but also contacts to aromatic rings at one side of the pore. We have derived the energy profile of a gliding maltooligosaccharide by following formation and breakage of hydrogen bonds and by assessing the saccharide-aromatics interactions from a statistical analysis of saccharide binding sites in proteins. The resulting profile indicates smooth permeation despite extensive hydrogen bonding at the orifice. PMID:9144780
High Amplitude Acoustic Behavior of a Slit-Orifice Backed by a Cavity
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Gaeta, R. J., Jr.; DAgostino, M.; Jones, Mike (Technical Monitor)
2000-01-01
The objective of the study reported here was to acquire detailed acoustic data and limited and flow visualization data for numerical validation a new model of sound absorption by a very narrow rectangular slit backed by a cavity. The sound absorption model is being developed by Dr. C. K. W. Tam of Florida State University. This report documents normal incidence impedance measurements of a singular rectangular slit orifice with no mean flow. All impedance measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube using the two-microphone method for several frequencies in the range 1000-6000Hz and incident sound pressure levels in the range 130 - 150 dB. In the interest of leaving the analysis of the data to the developers of more advanced analytical and computational models of sound absorption by narrow slits, we have refrained from giving our own explanations of the observed results, although many of the observed results can be explained using the classical explanations of sound absorption by orifices.
High Amplitude Acoustic Behavior of a Slit-Orifice Backed by a Cavity
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Gaeta, R. J., Jr.; DAgostino, M.
2000-01-01
The objective of this study was to acquire detailed acoustic data and limited flow visualization data for numerical validation of a new model of sound absorption by a very narrow rectangular slit backed by a cavity. The sound absorption model is that being developed by Dr. C. K. W. Tam of Florida State University. This report documents normal incidence impedance measurements of a singular rectangular slit orifice with no mean flow. All impedance measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube using the two-microphone method for several frequencies in the range 1000 - 6000Hz and incident sound pressure levels in the range 130 - 150 dB. In the interest of leaving the analysis of the data to the developers of more advanced Analytical and computational models of sound absorption by narrow slits, we authors have refrained from giving our own explanations of the observed results, although many of the observed results can be explained using the classical understanding of sound absorption by orifices.
Active bypass flow control for a seal in a gas turbine engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebert, Todd A.; Kimmel, Keith D.
An active bypass flow control system for controlling bypass compressed air based upon leakage flow of compressed air flowing past an outer balance seal between a stator and rotor of a first stage of a gas turbine in a gas turbine engine is disclosed. The active bypass flow control system is an adjustable system in which one or more metering devices may be used to control the flow of bypass compressed air as the flow of compressed air past the outer balance seal changes over time as the outer balance seal between the rim cavity and the cooling cavity wearsmore » In at least one embodiment, the metering device may include an annular ring having at least one metering orifice extending therethrough, whereby alignment of the metering orifice with the outlet may be adjustable to change a cross-sectional area of an opening of aligned portions of the outlet and the metering orifice.« less
Feng, X; Huang, Z C; Tao, F; Ou, X L
2016-02-01
To investigate clinical aspects and a new operative method for resecting third branchial fistula. The clinical aspects of 4 patients with third branchial fistula were retrospectively analyzed. It is difficult to locate the inner orifice of fistula through neck path due to tiny diameter of inner orifice. The inner orifice could be found and closed effectively by inserting yellow zebra guidewire from sinus piriformis with gastroscope. The mucous membrane of sinus piriformis could not be damaged due to the soft pointed end of yellow zebra guidewire. 4 cases were treated successfully without pharyngeal fistula or recurrent laryngeal nerve injury. No recurrent infections were found in all cases with follows-up of 6-66 months. Ineffectiveness of radiography with meglumine diatrizoate or oral administration of methylene blue before operation indicates tiny fistula. In this case, resection of third branchial fistula with the assistance of gastroscope and yellow zebra guidewire under general anesthesia can be performed. This innovative method of diagnosis and treatment is worth of application clinically.
A voice-actuated wind tunnel model leak checking system
NASA Technical Reports Server (NTRS)
Larson, William E.
1989-01-01
A computer program has been developed that improves the efficiency of wind tunnel model leak checking. The program uses a voice recognition unit to relay a technician's commands to the computer. The computer, after receiving a command, can respond to the technician via a voice response unit. Information about the model pressure orifice being checked is displayed on a gas-plasma terminal. On command, the program records up to 30 seconds of pressure data. After the recording is complete, the raw data and a straight line fit of the data are plotted on the terminal. This allows the technician to make a decision on the integrity of the orifice being checked. All results of the leak check program are stored in a database file that can be listed on the line printer for record keeping purposes or displayed on the terminal to help the technician find unchecked orifices. This program allows one technician to check a model for leaks instead of the two or three previously required.
Method and device for controlling plume during laser welding
Fuerschbach, Phillip W.; Jellison, James L.; Keicher, David M.; Oberkampf, William L.
1991-01-01
A method and apparatus for enhancing the weldment of a laser welding system is provided. The laser weld plume control device includes a cylindrical body defining an upside-down cone cavity; the upper surface of the body circumscribes the base of the cone cavity, and the vertex of the cone cavity forms an orifice concentrically located with respect to the laser beam and the plume which forms as a result of the welding operation. According to the method of the invention, gas is directed radially inward through inlets in the upper surface of the body into and through channels in the wall of the body and finally through the orifice of the body, and downward onto the surface of the weldment. The gas flow is then converted by the orifice of the device from radial flow to an axisymmetric gas jet flowing away from the weldment surface in a direction perpendicular to the surface and opposite to that of the laser.
The Experiment of the Clog Reduction in a Plane Silo
NASA Astrophysics Data System (ADS)
Sun, Ai-Le; Zhang, Jie
2017-06-01
The flow of particles may be clogged when they pass through a narrow orifice. Many factors can change the probability of clogging, such as the outlet size, the presence of obstacles and external perturbation, but the detailed mechanisms are still unclear. In this paper, we present an experimental study of reduction of the clogging probability in a horizontal plane silo, which consists of a layer of elastic particles transported on an annular flat plate rotating with a constant angular velocity passing through a hopper structure. We found the exponential distributions of the avalanche size for different sizes of orifice and the power law tails of the passing time between two particles. We did not confirm whether there was a critical size of orifice above which the clogging became impossible. We explored the effect of the obstacle on the probability of clogging: and if we chose a proper obstacle placed at a proper position, the probability of clogging could be reduced by a factor of about seven.
NASA Astrophysics Data System (ADS)
Margulis, M. A.; Pil'Gunov, V. N.
2009-10-01
The mechanism of the effects observed in hydrodynamic unit throttles was studied. These effects included luminescence in the visible range localized in a microscopic toroidal volume and electric pulses when a dielectric liquid flew through a narrow passage orifice. Equations for charging and conduction currents were obtained. The stationary electric charge, potential, and field strength on the internal surface of a passage orifice were calculated. It was shown theoretically that the appearance of luminescence most probably occurred in electrical breakdowns in cavitation bubbles in the initial flow section inside the passage orifice. Electric charge formed not only during hydrodynamic cavitation but also in a laminar throttle in the absence of cavitation in the liquid; the electrokinetic mechanism applied to this phenomenon too. It was shown experimentally that electric charges appeared not only in plastic but also in metallic throttles. The suggested mechanism of light emission and electric charge appearance was in agreement with the experimental results.
Gaseous Nitrogen Orifice Mass Flow Calculator
NASA Technical Reports Server (NTRS)
Ritrivi, Charles
2013-01-01
The Gaseous Nitrogen (GN2) Orifice Mass Flow Calculator was used to determine Space Shuttle Orbiter Water Spray Boiler (WSB) GN2 high-pressure tank source depletion rates for various leak scenarios, and the ability of the GN2 consumables to support cooling of Auxiliary Power Unit (APU) lubrication during entry. The data was used to support flight rationale concerning loss of an orbiter APU/hydraulic system and mission work-arounds. The GN2 mass flow-rate calculator standardizes a method for rapid assessment of GN2 mass flow through various orifice sizes for various discharge coefficients, delta pressures, and temperatures. The calculator utilizes a 0.9-lb (0.4 kg) GN2 source regulated to 40 psia (.276 kPa). These parameters correspond to the Space Shuttle WSB GN2 Source and Water Tank Bellows, but can be changed in the spreadsheet to accommodate any system parameters. The calculator can be used to analyze a leak source, leak rate, gas consumables depletion time, and puncture diameter that simulates the measured GN2 system pressure drop.
Clogging of Joule-Thomson Devices in Liquid Hydrogen Handling
NASA Technical Reports Server (NTRS)
Jurns, John M.; Lekki, John D.
2009-01-01
Experiments conducted at the NASA Glenn Research Center indicate that Joule-Thomson devices become clogged when transferring liquid hydrogen (LH2), operating at a temperature range from 20.5 to 24.4 K. Blockage does not exist under all test conditions but is found to be sensitive to the inlet temperature of the LH2. At a subcooled inlet temperature of 20.5 K blockage consistently appears but is dissipated when the fluid temperature is raised above 24.5 K. Clogging steadily reduced flow rate through the orifices, eventually resulting in complete blockage. This tendency poses a threat to spacecraft cryogenic propulsion systems that would utilize passive thermal control systems. We propose that this clogging is due to trace amounts of neon in the regular LH2 supply. Neon freezes at 24.5 K at one atmosphere pressure. It is postulated that between 20.5 and 24.5 K, neon remains in a meta-stable, supercooled liquid state. When impacting the face of an orifice, liquid neon droplets solidify and accumulate, blocking flow over time. The purpose of this test program was to definitively quantify the phenomena experimentally by obtaining direct visual evidence of orifice clogging by accretion from neon contaminates in the LH2 flow stream, utilizing state of the art imaging technology. Tests were conducted with LH2 flowing in the temperature range of 20.5 to 24.4 K. Additional imaging was also done at LH2 temperatures with no flow to verify clear view through the orifice.
The impact of loupes and microscopes on vision in endodontics.
Perrin, P; Neuhaus, K W; Lussi, A
2014-05-01
To report on an intraradicular visual test in a simulated clinical setting under different optical conditions. Miniaturized visual tests with E-optotypes (bar distance from 0.01 to 0.05 mm) were fixed inside the root canal system of an extracted maxillary molar at different locations: at the orifice, a depth of 5 mm and the apex. The tooth was mounted in a phantom head for a simulated clinical setting. Unaided vision was compared with Galilean loupes (2.5× magnification) with integrated light source and an operating microscope (6× magnification). The influence of the dentists' age within two groups was evaluated: <40 years (n = 9) and ≥40 years (n = 15). Some younger dentists were able to identify the E-optotypes at the orifice, but otherwise, natural vision did not reveal any measurable result. With Galilean loupes, the younger dentists <40 years could see a 0.05 mm structure at the root canal orifice, in contrast to the older group ≥40 years. Only the microscope allowed the observation of structures inside the root canal, independent of age. Unaided vision and Galilean loupes with an integrated light source could not provide any measurable vision inside the root canal, but younger dentists <40 years could detect with Galilean loupes a canal orifice corresponding to the tip of the smallest endodontic instruments. Dentists over 40 years of age were dependent on the microscope to inspect the root canal system. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Effect of the Mitral Valve's Anterior Leaflet on Axisymmetry of Transmitral Vortex Ring.
Falahatpisheh, Ahmad; Pahlevan, Niema M; Kheradvar, Arash
2015-10-01
The shape and formation of transmitral vortex ring are shown to be associated with diastolic function of the left ventricle (LV). Transmitral vortex ring is a flow feature that is observed to be non-axisymmetric in a healthy heart and its inherent asymmetry in the LV assists in efficient ejection of the blood during systole. This study is a first step towards understanding the effects of the mitral valve's anterior leaflet on transmitral flow. We experimentally study a single-leaflet model of the mitral valve to investigate the effect of the anterior leaflet on the axisymmetry of the generated vortex ring based on the three-dimensional data acquired using defocusing digital particle image velocimetry. Vortex rings form downstream of a D-shaped orifice in presence or absence of the anterior leaflet in various physiological stroke ratios. The results of the statistical analysis indicate that the formed vortex ring downstream of a D-shaped orifice is markedly non-axisymmetric, and presence of the anterior leaflet improves the ring's axisymmetry. This study suggests that the improvement of axisymmetry in presence of the anterior leaflet might be due to coupled dynamic interaction between rolling-up of the shear layer at the edges of the D-shaped orifice and the borders of the anterior leaflet. This interaction can reduce the non-uniformity in vorticity generation, which results in more axisymmetric behavior compared to the D-shaped orifice without the anterior leaflet.
Forgione, A
2009-06-01
The possibility to operate inside the peritoneal cavity through small holes performed in hollow organs that is presented by Natural Orifice Transluminal Endoscopic Surgery (NOTES) represents a major paradigm shift in general surgery. While this new approach seems very appealing from patients' perspectives because it eliminates completely abdominal wall aggression and promises to reduce postoperative pain, it is very challenging for surgeons because of the major constraints imposed by both the mode of access and the limited technology currently available. For this reason NOTES applications at the present time are performed by only a few surgeons and mainly to perform non-complex procedures. While new devices are under development, many of them are trying mainly to simply improve current endoscopic platforms and seem not to offer breakthrough solutions. The numerous challenges introduced by natural orifice approaches require a radical shift in the conception of new technologies in order to make this emerging operative access safe and reproducible. The convergence of several enabling technologies in the field of miniaturization, communication and micro-mechatronics brings the possibility to realize on a large scale the revolutionary concept of miniature in vivo co-operative robots. These robots provide vision and task assistance without the constraints of the entry incision and have been shown in experimental settings to possess many qualities that could be ideal to partner with Natural Orifice Surgery. This article explores the current status of microrobotics as well as presents potential future scenarios of their applications in NOTES.
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Srinivasan, R.
1986-01-01
A microcomputer code which displays 3-D oblique and 2-D plots of the temperature distribution downstream of jets mixing with a confined crossflow has been used to investigate the effects of varying the several independent flow and geometric parameters on the mixing. Temperature profiles calculated with this empirical model are presented to show the effects of orifice size and spacing, momentum flux ratio, density ratio, variable temperature mainstream, flow area convergence, orifice aspect ratio, and opposed and axially staged rows of jets.
REFLECTOR CONTROL OF A BOILING-WATER REACTOR
Treshow, M.
1962-05-22
A line connecting the reactor with a spent steam condenser contains a valve set to open when the pressure in the reactor exceeds a predetermined value and an orifice on the upstream side of the valve. Another line connects the reflector with this line between the orifice and the valve. An excess steam pressure causes the valve to open and the flow of steam through the line draws water out of the reflector. Provision is also made for adding water to the reflector when the steam pressure drops. (AEC)
Orthodontic parotitis: a rare complication from an orthodontic appliance.
McCarthy, Eileen; Cobb, Alistair R M
2012-12-01
A case is presented of a 14-year-old female undergoing orthodontic fixed appliance treatment who presented with right facial swelling in the parotid region. An initial diagnosis of acute infective parotitis was made by her primary care clinician. However, after clinical examination and ultrasonographic imaging, a diagnosis of salivary stasis secondary to inflammatory occlusion of Stensen's ductal orifice was made. The ductal orifice had been traumatized by the adjacent orthodontic appliance. This has not been described before in the literature. The differential diagnosis of parotid enlargement in children is discussed.
An investigation of the Attenuation Provided by the Surefire EP3 Sonic Defender (Trademark) Earplug
2008-05-01
Reine (en droit du Canada), telle que représentée par le ministre de la Défense nationale, 2008 DRDC Toronto TR 2008-040 i Abstract...Surefire chez cinq hommes et cinq femmes. Selon le fabricant, un orifice percé dans le bouchon permet aux sons dont le niveau est sans danger de ...dispositif avec l’orifice ouvert et fermé en l’absence de bruits impulsifs. Cinq hommes et cinq femmes y ont participé. Le seuil d’audibilité de chaque
NASA Technical Reports Server (NTRS)
Spanogle, J A; Foster, H H
1930-01-01
This report presents test results obtained at the Langley Memorial Aeronautical Laboratory of the National Advisory Committee for Aeronautics during an investigation to determine the relative performance of a single-cylinder, high-speed, compression-ignition engine when using fuel injection valve nozzles with different numbers, sizes, and directions of round orifices. A spring-loaded, automatic injection valve was used, centrally located at the top of a vertical disk-type combustion chamber formed between horizontally opposed inlet and exhaust valves of a 5 inch by 7 inch engine.
Penetration and Duration of Fuel Sprays from a Pump Injection System
NASA Technical Reports Server (NTRS)
Rothrock, A M; Marsh, E T
1931-01-01
High-speed motion pictures were taken of individual fuel sprays from a pump injection system. The changes in the spray-tip penetration with changes in the pump speed, injection-valve opening and closing pressures, discharge-orifice area, injection-tube length and diameter, and pump throttle setting were measured. In addition, the effects of the variables on the time lag and duration of injection can be controlled by the dimensions of the injection tube, the area of the discharge orifice, and the injection-valve opening and closing pressures.
Penetration and Duration of Fuel Sprays from a Pump Injection System
NASA Technical Reports Server (NTRS)
Rothrock, A M; Marsh, E T
1934-01-01
High-speed motion pictures were taken of individual fuel sprays from a pump injection system. The changes in the spray-tip penetration with changes in the pump speed, injection-valve opening and closing pressures, discharge-orifice area, injection-tube length and diameter, and pump throttle setting were measured. The pump was used with and without a check valve. The results show that the penetration of the spray tip can be controlled by the dimensions of the injection tube, the area of the discharge orifice, and the injection-valve opening and closing pressures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jayaweera, Indira; Krishnan, Gopala N.; Sanjurjo, Angel
2016-04-26
The invention provides methods for preparing an asymmetric hollow fiber, the asymmetric hollow fibers prepared by such methods, and uses of the asymmetric hollow fibers. One method involves passing a polymeric solution through an outer annular orifice of a tube-in-orifice spinneret, passing a bore fluid though an inner tube of the spinneret, dropping the polymeric solution and bore fluid through an atmosphere over a dropping distance, and quenching the polymeric solution and bore fluid in a bath to form an asymmetric hollow fiber.
Intradermal needle-free powdered drug injection by a helium-powered device.
Liu, John; Hogan, N Catherine; Hunter, Ian W
2012-01-01
We present a new method for needle-free powdered drug injection via a bench-top gas-powered device. This injector provides an alternative method of vaccine delivery to address the cold chain problem--the cost and risk of transporting temperature sensitive vaccines to developing countries. The device houses interchangeable nozzle inserts to vary orifice geometries and is capable of delivering polymer beads (1-5 µm diameter) into the dermal layer of porcine tissue. Results for injection shape and injection depth versus nozzle orifice diameter demonstrate the device's controllability.
Basiri Parsa, Jalal; Ebrahimzadeh Zonouzian, Seyyed Alireza
2013-11-01
A low pressure pilot scale hydrodynamic cavitation (HC) reactor with 30 L volume, using fixed scrap iron sheets, as the heterogeneous catalyst, with no external source of H2O2 was devised to investigate the effects of operating parameters of the HC reactor performance. In situ generation of Fenton reagents suggested an induced advanced Fenton process (IAFP) to explain the enhancing effect of the used catalyst in the HC process. The reactor optimization was done based upon the extent of decolorization (ED) of aqueous solution of Rhodamine B (RhB). To have a perfect study on the pertinent parameters of the heterogeneous catalyzed HC reactor, the following cases as, the effects of scrap iron sheets, inlet pressure (2.4-5.8 bar), the distance between orifice plates and catalyst sheets (submerged and inline located orifice plates), back-pressure (2-6 bar), orifice plates type (4 various orifice plates), pH (2-10) and initial RhB concentration (2-14 mg L(-1)) have been investigated. The results showed that the highest cavitational yield can be obtained at pH 3 and initial dye concentration of 10 mg L(-1). Also, an increase in the inlet pressure would lead to an increase in the ED. In addition, it was found that using the deeper holes (thicker orifice plates) would lead to lower ED, and holes with larger diameter would lead to the higher ED in the same cross-sectional area, but in the same holes' diameters, higher cross-sectional area leads to the lower ED. The submerged operation mode showed a greater cavitational effects rather than the inline mode. Also, for the inline mode, the optimum value of 3 bar was obtained for the back-pressure condition in the system. Moreover, according to the analysis of changes in the UV-Vis spectra of RhB, both degradation of RhB chromophore structure and N-deethylation were occurred during the catalyzed HC process. Copyright © 2013 Elsevier B.V. All rights reserved.
Little, Stephen H; Pirat, Bahar; Kumar, Rahul; Igo, Stephen R; McCulloch, Marti; Hartley, Craig J; Xu, Jiaqiong; Zoghbi, William A
2008-11-01
Our goal was to prospectively compare the accuracy of real-time three-dimensional (3D) color Doppler vena contracta (VC) area and two-dimensional (2D) VC diameter in an in vitro model and in the clinical assessment of mitral regurgitation (MR) severity. Real-time 3D color Doppler allows direct measurement of VC area and may be more accurate for assessment of MR than the conventional VC diameter measurement by 2D color Doppler. Using a circulatory loop with an incorporated imaging chamber, various pulsatile flow rates of MR were driven through 4 differently sized orifices. In a clinical study of patients with at least mild MR, regurgitation severity was assessed quantitatively using Doppler-derived effective regurgitant orifice area (EROA), and semiquantitatively as recommended by the American Society of Echocardiography. We describe a step-by-step process to accurately identify the 3D-VC area and compare that measure against known orifice areas (in vitro study) and EROA (clinical study). In vitro, 3D-VC area demonstrated the strongest correlation with known orifice area (r = 0.92, p < 0.001), whereas 2D-VC diameter had a weak correlation with orifice area (r = 0.56, p = 0.01). In a clinical study of 61 patients, 3D-VC area correlated with Doppler-derived EROA (r = 0.85, p < 0.001); the relation was stronger than for 2D-VC diameter (r = 0.67, p < 0.001). The advantage of 3D-VC area over 2D-VC diameter was more pronounced in eccentric jets (r = 0.87, p < 0.001 vs. r = 0.6, p < 0.001, respectively) and in moderate-to-severe or severe MR (r = 0.80, p < 0.001 vs. r = 0.18, p = 0.4, respectively). Measurement of VC area is feasible with real-time 3D color Doppler and provides a simple parameter that accurately reflects MR severity, particularly in eccentric and clinically significant MR where geometric assumptions may be challenging.
Little, Stephen H.; Pirat, Bahar; Kumar, Rahul; Igo, Stephen R.; McCulloch, Marti; Hartley, Craig J.; Xu, Jiaqiong; Zoghbi, William A.
2012-01-01
OBJECTIVES Our goal was to prospectively compare the accuracy of real-time three-dimensional (3D) color Doppler vena contracta (VC) area and two-dimensional (2D) VC diameter in an in vitro model and in the clinical assessment of mitral regurgitation (MR) severity. BACKGROUND Real-time 3D color Doppler allows direct measurement of VC area and may be more accurate for assessment of MR than the conventional VC diameter measurement by 2D color Doppler. METHODS Using a circulatory loop with an incorporated imaging chamber, various pulsatile flow rates of MR were driven through 4 differently sized orifices. In a clinical study of patients with at least mild MR, regurgitation severity was assessed quantitatively using Doppler-derived effective regurgitant orifice area (EROA), and semiquantitatively as recommended by the American Society of Echocardiography. We describe a step-by-step process to accurately identify the 3D-VC area and compare that measure against known orifice areas (in vitro study) and EROA (clinical study). RESULTS In vitro, 3D-VC area demonstrated the strongest correlation with known orifice area (r = 0.92, p < 0.001), whereas 2D-VC diameter had a weak correlation with orifice area (r = 0.56, p = 0.01). In a clinical study of 61 patients, 3D-VC area correlated with Doppler-derived EROA (r = 0.85, p < 0.001); the relation was stronger than for 2D-VC diameter (r = 0.67, p < 0.001). The advantage of 3D-VC area over 2D-VC diameter was more pronounced in eccentric jets (r = 0.87, p < 0.001 vs. r = 0.6, p < 0.001, respectively) and in moderate-to-severe or severe MR (r = 0.80, p < 0.001 vs. r = 0.18, p = 0.4, respectively). CONCLUSIONS Measurement of VC area is feasible with real-time 3D color Doppler and provides a simple parameter that accurately reflects MR severity, particularly in eccentric and clinically significant MR where geometric assumptions may be challenging. PMID:19356505
Effect of altitude on spirometric parameters and the performance of peak flow meters.
Pollard, A. J.; Mason, N. P.; Barry, P. W.; Pollard, R. C.; Collier, D. J.; Fraser, R. S.; Miller, M. R.; Milledge, J. S.
1996-01-01
BACKGROUND: Portable peak flow meters are used in clinical practice for measurement of peak expiratory flow (PEF) at many different altitudes throughout the world. Some PEF meters are affected by gas density. This study was undertaken to establish which type of meter is best for use above sea level and to determine changes in spirometric measurements at altitude. METHODS: The variable orifice mini-Wright peak flow meter was compared with the fixed orifice Micro Medical Microplus turbine microspirometer at sea level and at Everest Base Camp (5300 m). Fifty one members of the 1994 British Mount Everest Medical Expedition were studied (age range, 19-55). RESULTS: Mean forced vital capacity (FVC) fell by 5% and PEF rose by 25.5%. However, PEF recorded with the mini-Wright peak flow meter underestimated PEF by 31%, giving readings 6.6% below sea level values. FVC was lowest in the mornings and did not improve significantly with acclimatisation. Lower PEF values were observed on morning readings and were associated with higher acute mountain sickness scores, although the latter may reflect decreased effort in those with acute mountain sickness. There was no change in forced expiratory volume in one second (FEV1) at altitude when measured with the turbine microspirometer. CONCLUSIONS: The cause of the fall in FVC at 5300 m is unknown but may be attributed to changes in lung blood volume, interstitial lung oedema, or early airways closure. Variable orifice peak flow meters grossly underestimate PEF at altitude and fixed orifice devices are therefore preferable where accurate PEF measurements are required above sea level. PMID:8711651
Decolourization of Rhodamine B: A swirling jet-induced cavitation combined with NaOCl.
Mancuso, Giuseppe; Langone, Michela; Laezza, Marco; Andreottola, Gianni
2016-09-01
A hydrodynamic cavitation reactor (Ecowirl) based on swirling jet-induced cavitation has been used in order to allow the degradation of a waste dye aqueous solution (Rhodamine B, RhB). Cavitation generated by Ecowirl reactor was directly compared with cavitation generated by using multiple hole orifice plates. The effects of operating conditions and parameters such as pressure, pH of dye solution, initial concentration of RhB and geometry of the cavitating devices on the degradation rate of RhB were discussed. In similar operative conditions, higher extents of degradation (ED) were obtained using Ecowirl reactor rather than orifice plate. An increase in the ED from 8.6% to 14.7% was observed moving from hole orifice plates to Ecowirl reactor. Intensification in ED of RhB by using hydrodynamic cavitation in presence of NaOCl as additive has been studied. It was found that the decolourization was most efficient for the combination of hydrodynamic cavitation and chemical oxidation as compared to chemical oxidation and hydrodynamic cavitation alone. The value of ED of 83.4% was reached in 37min using Ecowirl combined with NaOCl (4.0mgL(-1)) as compared to the 100min needed by only mixing NaOCl at the same concentration. At last, the energetic consumptions of the cavitation devices have been evaluated. Increasing the ED and reducing the treatment time, Ecowirl reactor resulted to be more energy efficient as compared to hole orifice plates, Venturi and other swirling jet-induced cavitation devices, as reported in literature. Copyright © 2016 Elsevier B.V. All rights reserved.
Startup of RAPID-L Lunar Base Reactor by Lithium Release Module
NASA Astrophysics Data System (ADS)
Kambe, Mitsuru
The 200 kWe uranium-nitride fueled lithium cooled fast reactor concept RAPID-L to be combined with thermoelectric power conversion system for lunar base power system is demonstrated. Unique challenges in reactivity control systems design have been attempted in RAPID-L concept. The reactor involves the following innovative reactivity control systems: Lithium Expansion Modules (LEM) for inherent reactivity feedback, Lithium Injection Modules (LIM) for inherent ultimate shutdown, and Lithium Release Modules (LRM) for automated reactor startup. All these systems adopt lithium-6 as a liquid poison instead of conventional B4C rods or Be reflectors. These systems are effective independent of the magnitude and direction of the gravity force. In 2006, however, the following design amendment has been made. 1) B4C poison rods were added to ensure criticality safety in unintended positive reactivity insertion by LRMs due to fire in the launch phase accident; because LRM freeze seal melts at 800°C which result in positive reactivity insertion. 2) Lower hot standby temperature of 200°C was adopted instead of conventional 800°C to reduce the external power at the startup. In this paper, development of the LRM orifice which dominates the startup transient of RAPID-L is discussed. An attention was focused how to achieve sufficiently small flow rate of 6Li in the orifice because it enables moderate positive reactivity insertion rate. The LRM orifice performance has been confirmed using 0.5 mm diameter SUS316 orifice/lithium flow test setup in the glove box.
Depressurization and two-phase flow of water containing high levels of dissolved nitrogen gas
NASA Technical Reports Server (NTRS)
Simoneau, R. J.
1981-01-01
Depressurization of water containing various concentrations of dissolved nitrogen gas was studied. In a nonflow depressurization experiment, water with very high nitrogen content was depressurized at rates from 0.09 to 0.50 MPa per second and a metastable behavior which was a strong function of the depressurization rate was observed. Flow experiments were performed in an axisymmetric, converging diverging nozzle, a two dimensional, converging nozzle with glass sidewalls, and a sharp edge orifice. The converging diverging nozzle exhibited choked flow behavior even at nitrogen concentration levels as low as 4 percent of the saturation level. The flow rates were independent of concentration level. Flow in the two dimensional, converging, visual nozzle appeared to have a sufficient pressure drop at the throat to cause nitrogen to come out of solution, but choking occurred further downstream. The orifice flow motion pictures showed considerable oscillation downstream of the orifice and parallel to the flow. Nitrogen bubbles appeared in the flow at back pressures as high as 3.28 MPa, and the level at which bubbles were no longer visible was a function of nitrogen concentration.
Diagnostic Techniques to Elucidate the Aerodynamic Performance of Acoustic Liners
NASA Technical Reports Server (NTRS)
June, Jason; Bertolucci, Brandon; Ukeiley, Lawrence; Cattafesta, Louis N., III; Sheplak, Mark
2017-01-01
In support of Topic A.2.8 of NASA NRA NNH10ZEA001N, the University of Florida (UF) has investigated the use of flow field optical diagnostic and micromachined sensor-based techniques for assessing the wall shear stress on an acoustic liner. Stereoscopic particle image velocimetry (sPIV) was used to study the velocity field over a liner in the Grazing Flow Impedance Duct (GFID). The results indicate that the use of a control volume based method to determine the wall shear stress is prone to significant error. The skin friction over the liner as measured using velocity curve fitting techniques was shown to be locally reduced behind an orifice, relative to the hard wall case in a streamwise plane centered on the orifice. The capacitive wall shear stress sensor exhibited a linear response for a range of shear stresses over a hard wall. PIV over the liner is consistent with lifting of the near wall turbulent structure as it passes over an orifice, followed by a region of low wall shear stress.
Transverse Injection into Subsonic Crossflow with Various Injector Orifice Geometries
NASA Technical Reports Server (NTRS)
Foster, Lancert E.; Zaman, Khairul B.
2010-01-01
Computational and experimental results are presented for a case study of single injectors employed in 90 deg transverse injection into a non-reacting subsonic flow. Different injector orifice shapes are used (including circular, square, diamond-shaped, and wide rectangular slot), all with constant cross-sectional area, to observe the effects of this variation on injector penetration and mixing. Whereas the circle, square, and diamond injector produce similar jet plumes, the wide rectangular slot produces a plume with less vertical penetration than the others. There is also some evidence that the diamond injector produces slightly faster penetration with less mixing of the injected fluid. In addition, a variety of rectangular injectors were analyzed, with varying length/width ratios. Both experimental and computational data show improved plume penetration with increased streamwise orifice length. 3-D Reynolds-Averaged Navier-Stokes (RANS) results are obtained for the various injector geometries using NCC (National Combustion Code) with the kappa-epsilon turbulence model in multi-species modes on an unstructured grid. Grid sensitivity results are also presented which indicate consistent qualitative trends in the injector performance comparisons with increasing grid refinement.
Cheng, Lei; Jiang, Yao; Yan, Ni; Shan, Shu-Feng; Liu, Xiao-Qin; Sun, Lin-Bing
2016-09-07
Selective adsorption and efficient regeneration are two crucial issues for adsorption processes; unfortunately, only one of them instead of both is favored by traditional adsorbents with fixed pore orifices. Herein, we fabricated a new generation of smart adsorbents through grafting photoresponsive molecules, namely, 4-(3-triethoxysilylpropyl-ureido)azobenzene (AB-TPI), onto pore orifices of the support mesoporous silica. The azobenzene (AB) derivatives serve as the molecular gates of mesopores and are reversibly opened and closed upon light irradiation. Irradiation with visible light (450 nm) causes AB molecules to isomerize from cis to trans configuration, and the molecular gates are closed. It is easy for smaller adsorbates to enter while difficult for the larger ones, and the selective adsorption is consequently facilitated. Upon irradiation with UV light (365 nm), the AB molecules are transformed from trans to cis isomers, promoting the desorption of adsorbates due to the opened molecular gates. The present smart adsorbents can consequently benefit not only selective adsorption but also efficient desorption, which are exceedingly desirable for adsorptive separation but impossible for traditional adsorbents with fixed pore orifices.
Numerical mixing calculations of confined reacting jet flows in a cylindrical duct
NASA Technical Reports Server (NTRS)
Oechsle, Victor L.; Holdeman, J. D.
1995-01-01
The results reported in this paper describe some of the main flow characteristics and NOx production results which develop in the mixing process in a constant cross-sectional cylindrical duct. A 3-dimensional numerical model has been used to predict the mixing flow field and NOx characteristics in a mixing section of an RQL combustor. Eighteen configurations have been analyzed in a circular geometry in a fully reacting environment simulating the operating condition of an actual RQL gas turbine combustion liner. The evaluation matrix was constructed by varying three parameter: (1) jet-to-mainstream momentum-flux ration (J), (2) orifice shape or orifice aspect ratio, and (3) slot slant angle. The results indicate that the mixing flow field and NOx production significantly vary with the value of the jet penetration and subsequently, slanting elongated slots generally improve the NOx production at high J conditions. Round orifices produce low NOx at low J due to the strong jet penetration. The NOx production trends do not correlate with the mixing non-uniformity parameters described herein.
Computerized method and system for designing an aerodynamic focusing lens stack
Gard, Eric [San Francisco, CA; Riot, Vincent [Oakland, CA; Coffee, Keith [Diablo Grande, CA; Woods, Bruce [Livermore, CA; Tobias, Herbert [Kensington, CA; Birch, Jim [Albany, CA; Weisgraber, Todd [Brentwood, CA
2011-11-22
A computerized method and system for designing an aerodynamic focusing lens stack, using input from a designer related to, for example, particle size range to be considered, characteristics of the gas to be flowed through the system, the upstream temperature and pressure at the top of a first focusing lens, the flow rate through the aerodynamic focusing lens stack equivalent at atmosphere pressure; and a Stokes number range. Based on the design parameters, the method and system determines the total number of focusing lenses and their respective orifice diameters required to focus the particle size range to be considered, by first calculating for the orifice diameter of the first focusing lens in the Stokes formula, and then using that value to determine, in iterative fashion, intermediate flow values which are themselves used to determine the orifice diameters of each succeeding focusing lens in the stack design, with the results being output to a designer. In addition, the Reynolds numbers associated with each focusing lens as well as exit nozzle size may also be determined to enhance the stack design.
Solid metabolic waste transport and stowage investigation
NASA Technical Reports Server (NTRS)
Burt, R. A.; Koesterer, M. G.; Hunt, S. R., Jr.
1974-01-01
The basic Waste Collection System (WCS) design under consideration utilized air flow to separate the stool from the WCS user and to transport the fecal material to a slinger device for subsequent deposition on a storage bowel. The major parameters governing stool separation and transport were found to be the area of the air inlet orifices, the configuration of the air inlet orifice and the transport air flow. Separation force and transport velocity of the stool were studied. The developed inlet orifice configuration was found to be an effective design for providing fecal separation and transport. Simulated urine tests and female user tests in zero gravity established air flow rates between 0.08 and 0.25 cu sm/min (3 and 9 scfm) as satisfactory for entrapment, containment and transport of urine using an urinal. The investigation of air drying of fecal material as a substitute for vacuum drying in a WCS breadboard system showed that using baseline conditions anticipated for the shuttle cabin ambient atmosphere, flow rates of 0.14 cu sm/min (5 cfm) were adequate for drying and maintaining biological stability of the fecal material.
Fuel control for gas turbine with continuous pilot flame
Swick, Robert M.
1983-01-01
An improved fuel control for a gas turbine engine having a continuous pilot flame and a fuel distribution system including a pump drawing fuel from a source and supplying a line to the main fuel nozzle of the engine, the improvement being a control loop between the pump outlet and the pump inlet to bypass fuel, an electronically controlled throttle valve to restrict flow in the control loop when main nozzle demand exists and to permit substantially unrestricted flow without main nozzle demand, a minimum flow valve in the control loop downstream of the throttle valve to maintain a minimum pressure in the loop ahead of the flow valve, a branch tube from the pilot flame nozzle to the control loop between the throttle valve and the minimum flow valve, an orifice in the branch tube, and a feedback tube from the branch tube downstream of the orifice to the minimum flow valve, the minimum flow valve being operative to maintain a substantially constant pressure differential across the orifice to maintain constant fuel flow to the pilot flame nozzle.
NASA Technical Reports Server (NTRS)
Woronowicz, Michael S.
2016-01-01
Analytical expressions for column number density (CND) are developed for optical line of sight paths through a variety of steady free molecule point source models including directionally-constrained effusion (Mach number M = 0) and flow from a sonic orifice (M 1). Sonic orifice solutions are approximate, developed using a fair simulacrum fitted to the free molecule solution. Expressions are also developed for a spherically-symmetric thermal expansion (M = 0). CND solutions are found for the most general paths relative to these sources and briefly explored. It is determined that the maximum CND from a distant location through directed effusion and sonic orifice cases occurs along the path parallel to the source plane that intersects the plume axis. For the effusive case this value is exactly twice the CND found along the ray originating from that point of intersection and extending to infinity along the plumes axis. For sonic plumes this ratio is reduced to about 43. For high Mach number cases the maximum CND will be found along the axial centerline path.
Tian, Yu; Wu, Shuo-Dong; Chen, Ying-Han; Wang, Dan-Bo
2014-01-01
Background Natural orifice transluminal endoscopic surgery (NOTES) involves the introduction of instruments through a natural orifice into the peritoneal cavity to perform surgical interventions. The vagina is the most widely used approach to NOTES. We report the utilization of the vaginal opening at the time of vaginal hysterectomy as a natural orifice for laparoscopic appendectomy. Material/Methods We reviewed cases of 10 patients with chronic appendicitis who underwent transvaginal laparoscopic appendectomy simultaneously with vaginal hysterectomy. A laparoscopic approach was established after removal of the uterus, and the appendix was removed transvaginally. Among the 10 cases, 5 were conducted under gasless laparoscopy by using a simple abdominal wall-lifting instrument. Results All procedures were performed successfully without intraoperative or major postoperative complications. The appendectomy portion of the procedure took approximately 21 minutes to 34 minutes. All patients were discharged less than 4 days after surgery, without external scars. Conclusions Transvaginal appendectomy with rigid laparoscopic instruments following vaginal hysterectomy appears to be a feasible and safe modification of established techniques, with acceptable outcomes. PMID:25300522
Differential pressure sensing system for airfoils usable in turbine engines
Yang, Wen-Ching; Stampahar, Maria E.
2005-09-13
A detection system for identifying airfoils having a cooling systems with orifices that are plugged with contaminants or with showerheads having a portion burned off. The detection system measures pressures at different locations and calculates or measures a differential pressure. The differential pressure may be compared with a known benchmark value to determine whether the differential pressure has changed. Changes in the differential pressure may indicate that one or more of the orifices in a cooling system of an airfoil are plugged or that portions of, or all of, a showerhead has burned off.
DSMC simulation of the interaction between rarefied free jets
NASA Technical Reports Server (NTRS)
Dagum, Leonardo; Zhu, S. H. K.
1993-01-01
This paper presents a direct simulation Monte Carlo (DSMC) calculation of two interacting free jets exhausting into vacuum. The computed flow field is compared against available experimental data and shows excellent agreement everywhere except in the very near field (less than one orifice diameter downstream of the jet exhaust plane). The lack of agreement in this region is attributed to having assumed an inviscid boundary condition for the orifice lip. The results serve both to validate the DSMC code for a very complex, three dimensional non-equilibrium flow field, and to provide some insight as to the complicated nature of this flow.
Method and apparatus for fine tuning an orifice pulse tube refrigerator
Swift, Gregory W.; Wollan, John J.
2003-12-23
An orifice pulse tube refrigerator uses flow resistance, compliance, and inertance components connected to a pulse tube for establishing a phase relationship between oscillating pressure and oscillating velocity in the pulse tube. A temperature regulating system heats or cools a working gas in at least one of the flow resistance and inertance components. A temperature control system is connected to the temperature regulating system for controlling the temperature of the working gas in the at least one of the flow resistance and inertance components and maintains a control temperature that is indicative of a desired temporal phase relationship.
Air data system optimization using a genetic algorithm
NASA Technical Reports Server (NTRS)
Deshpande, Samir M.; Kumar, Renjith R.; Seywald, Hans; Siemers, Paul M., III
1992-01-01
An optimization method for flush-orifice air data system design has been developed using the Genetic Algorithm approach. The optimization of the orifice array minimizes the effect of normally distributed random noise in the pressure readings on the calculation of air data parameters, namely, angle of attack, sideslip angle and freestream dynamic pressure. The optimization method is applied to the design of Pressure Distribution/Air Data System experiment (PD/ADS) proposed for inclusion in the Aeroassist Flight Experiment (AFE). Results obtained by the Genetic Algorithm method are compared to the results obtained by conventional gradient search method.
Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts.
Isayama, Hiroyuki; Nakai, Yousuke; Hamada, Tsuyoshi; Matsubara, Saburo; Kogure, Hirofumi; Koike, Kazuhiko
2016-12-01
Self-expandable metallic stent (SEMS) was an effective biliary endoprosthesis. Mechanical properties of SEMS, radial and axial force (RF, AF), may play important roles in the bile duct after placement. RF was well known dilation force and influenced on the occurrence of migration. AF, newly proposed by this author, was defined as the recovery force when the SEMS vended. AF was related with the cause of bile duct kinking, pancreatitis, and cholecystitis due to the compression of the bile duct, orifice of the cystic duct, and pancreatic orifice. Ideal SEMS may show high RF and low AF.
NASA Technical Reports Server (NTRS)
Kandula, Max
2012-01-01
Experiments are performed in a 24.4 mm diameter choked circular hot and cold jets issuing from a sharp-edged orifice at a fully expanded jet Mach number of 1.85. The stagnation temperature of the hot and the cold jets are 319 K and 299 K respectively. The results suggest that temperature effects on the screech amplitude and frequency are manifested for the fundamental, with a reduced amplitude and increased frequency for hot jet relative to the cold jet. Temperature effects on the second harmonic are also observed.
Ice/water slurry blocking phenomenon at a tube orifice.
Hirochi, Takero; Yamada, Shuichi; Shintate, Tuyoshi; Shirakashi, Masataka
2002-10-01
The phenomenon of ice-particle/water mixture blocking flow through a pipeline is a problem that needs to be solved before mixture flow can be applied for practical use in cold energy transportation in a district cooling system. In this work, the blocking mechanism of ice-particle slurry at a tube orifice is investigated and a criterion for blocking is presented. The cohesive nature of ice particles is shown to cause compressed plug type blocking and the compressive yield stress of a particle cluster is presented as a measure for the cohesion strength of ice particles.
Tufted hair folliculitis: a case report and literature review.
Broshtilova, V; Bardarov, E; Kazandjieva, J; Marina, S
2011-01-01
Tufted hair folliculitis is a rare folliculitis of the scalp that resolves with patches of scarring alopecia within multiple hair tufts emerging from dilated follicular orifices. Tufting of hair is caused by clustering of adjacent follicular units due to a fibrosing process and to retention of telogen hairs within a dilated follicular orifice. Various pathogenetic mechanisms have been proposed including nevoid abnormalities, recurrent infections of the follicles, and retention of telogen hair in the tufts. We present a patient with tufted hair folliculitis who was effectively treated with antibacterial medications, verifying the infectious nature of the disease.
FRACTIONATING COLUMN PRODUCT COLLECTOR CONTROL
Paxson, G.D. Jr.
1964-03-10
Means for detecting minute fluid products from a chemical separation column and for advancing a collector tube rack in order to automatically separate and collect successive fractionated products are described. A charge is imposed on the forming drops at the column orifice to create an electric field as the drop falls in the vicinity of a sensing plate. The field is detected by an electrometer tube coupled to the plate causing an output signal to actuate rotation of a collector turntable rack, thereby positioning new collectors under the orifice. The invention provides reliable automatic collection independent of drop size, rate of fall, or chemical composition. (AEC)
Imaging of high-pressure fuel sprays in the near-nozzle region with supercontinuum illumination
NASA Astrophysics Data System (ADS)
Zheng, Yipeng; Si, Jinhai; Tan, Wenjiang; Wang, Mingxin; Yang, Bo; Hou, Xun
2018-04-01
We employ a supercontinuum (SC) illumination to image the high-pressure fuel sprays in the near-nozzle region. The effect of speckles in the images is significantly mitigated using the SC illumination to improve the identifiability of the microstructures in the spray. The microstructures in the near-nozzle region, i.e., lobes, holes, ligaments, and bridges, are clearly imaged for different fuel pressures and nozzle orifice diameters. The shadowgraphs captured in the experiments also show the spray cone angle of spray is strongly dependent on the injection pressures and nozzle orifice diameters.
[Natural orifice translumenal endoscopic surgery: historical and future perspectives].
Yasuda, Kazuhiro; Shiroshita, Hidefumi; Inomata, Masafumi; Kitano, Seigo
2013-11-01
Natural orifice translumenal endoscopic surgery (NOTES) has gained much attention worldwide since the first report of transgastric peritoneoscopy in a porcine model in 2004. In this review, we summarize and highlight the current status and future directions of NOTES. Thousands of human NOTES procedures have been performed. The most common procedures are cholecystectomy and appendectomy, mainly performed through transvaginal access in a hybrid fashion with laparoscopic assistance, and the general complication rate is acceptable. Although much work is still needed to refine the techniques for NOTES, the development of NOTES has the potential to create a paradigm shift in minimally invasive surgery.
NASA Astrophysics Data System (ADS)
Kadem, L.; Knapp, Y.; Pibarot, P.; Bertrand, E.; Garcia, D.; Durand, L. G.; Rieu, R.
2005-12-01
The effective orifice area (EOA) is the most commonly used parameter to assess the severity of aortic valve stenosis as well as the performance of valve substitutes. Particle image velocimetry (PIV) may be used for in vitro estimation of valve EOA. In the present study, we propose a new and simple method based on Howe’s developments of Lighthill’s aero-acoustic theory. This method is based on an acoustical source term (AST) to estimate the EOA from the transvalvular flow velocity measurements obtained by PIV. The EOAs measured by the AST method downstream of three sharp-edged orifices were in excellent agreement with the EOAs predicted from the potential flow theory used as the reference method in this study. Moreover, the AST method was more accurate than other conventional PIV methods based on streamlines, inflexion point or vorticity to predict the theoretical EOAs. The superiority of the AST method is likely due to the nonlinear form of the AST. There was also an excellent agreement between the EOAs measured by the AST method downstream of the three sharp-edged orifices as well as downstream of a bioprosthetic valve with those obtained by the conventional clinical method based on Doppler-echocardiographic measurements of transvalvular velocity. The results of this study suggest that this new simple PIV method provides an accurate estimation of the aortic valve flow EOA. This new method may thus be used as a reference method to estimate the EOA in experimental investigation of the performance of valve substitutes and to validate Doppler-echocardiographic measurements under various physiologic and pathologic flow conditions.
Liang, Weiqiang; Ji, Chenyang; Chen, Yuhong; Zhang, Ganling; Zhang, Jiaqi; Yao, Yuanyuan; Zhang, Jinming
2016-08-01
To evaluate the effects, particularly the incidence of anastomotic fistula, of a pedicled dartos flap around the urethral orifice in the treatment of urethroplasty of mid-shaft hypospadias. A total of 46 cases of congenital mid-shaft hypospadias were included in this study. The patients ranged in age from 0.7 to 25.4 years and the average was 5.8 years. The patients received penis chordee correction. A transverse preputial island flap was developed for urethral reconstruction. The proximal dartos of the urethral orifice was used to develop a pedicled dartos flap, which was transposed to cover and strengthen neourethral anastomosis. The ventral penile skin defect was repaired by another flap. The 46 patients were examined during follow-up visits for 6 months to 3 years. An anastomotic fistula was observed in one case (2.2 %). Scar healing without fistula was observed in another patient due to poor blood supply to part of the ventral penile skin. No other incidences of fistula, urethral rupture, flap necrosis, wound infections, urinary tract (meatal) stenosis, or urethral diverticulum were observed in the patients. A pedicled dartos flap around the urethral orifice can take advantage of well-vascularized local tissue to add a protective layer to the proximal aspect of the neourethral anastomosis for reducing the incidence of anastomotic fistula in mid-shaft hypospadias repair using a transverse preputial island flap. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Stamopoulos, Dimosthenis; Bakirtzi, Nerantzoula; Manios, Efthymios; Grapsa, Eirini
2013-01-01
In hemodialysis (HD) patients, anemia relates to three main factors: insufficient production of erythropoietin; impaired management of iron; and decreased lifespan of red blood cells (RBCs). The third factor can relate to structural deterioration of RBCs due to extrinsic (extracorporeal circuit; biochemical activation and/or mechanical stress during dialysis) and intrinsic (uremic milieu; biochemical interference of the RBC membrane constituents with toxins) mechanisms. Herein, we evaluate information accessed with advanced imaging techniques at the cellular level. Atomic force and scanning electron microscopes were employed to survey intact RBCs (iRBCs) of seven HD patients in comparison to seven healthy donors. The extrinsic factor was investigated by contrasting pre- and post-HD samples. The intrinsic environment was investigated by comparing the microscopy data with the clinical ones. The iRBC membranes of the enrolled HD patients were overpopulated with orifice-like (high incidence; typical size within 100-1,000 nm) and crevice-like (low incidence; typical size within 500-4,000 nm) defects that exhibited a statistically significant (P < 0.05) relative increase (+55% and +350%, respectively) in respect to healthy donors. The relative variation of the orifice and crevice indices (mean population of orifices and crevices per top membrane surface) between pre- and post-HD was not statistically significant (-3.3% and +4.5%, respectively). The orifice index correlates with the concentrations of urea, calcium, and phosphorus, but not, however, with that of creatinine. Extracorporeal circulation is not detrimental to the structural integrity of RBC membranes. Uremic milieu is a candidate cause of RBC membrane deterioration, which possibly worsens anemia.
Berdejo, Javier; Shiota, Maiko; Mihara, Hirotsugu; Itabashi, Yuji; Utsunomiya, Hiroto; Shiota, Takahiro
2017-05-01
Evaluation of eccentric mitral regurgitation (MR) remains extremely difficult and the role played by its etiology, functional or degenerative, is not well understood. This study aimed to demonstrate the value of three-dimensional transesophageal echocardiography (3DTEE) in the evaluation of eccentric MR identifying geometric differences in the vena contracta area between functional and degenerative etiologies. We studied 61 patients with eccentric MR (30 functional and 31 degenerative). Regurgitant orifice area was determined by the two-dimensional proximal isovelocity surface area (2DPISA) and the 3DTEE methods. The ratio between maximum and minimum lengths of the vena contracta was calculated in each patient. Effective regurgitant orifice area by the 2DPISA method was smaller than that estimated by 3DTEE (0.56±0.21 vs 0.72±0.25 cm 2 ). A better correlation between both methods was seen in degenerative mitral regurgitation (DMR; r=.83), with a mean underestimation of 8.2% by the 2DPISA method. A much worse correlation was found in functional mitral regurgitation (FMR; r=.39), where a mean underestimation by the 2DPISA method of 29.1% was observed. There was a more elongated and curved vena contracta in FMR compared to that in DMR (length ratio: 3.4±1.0 vs 2.2±0.7, P<.0001). Three-dimensional transesophageal echocardiography identifies a more elongated regurgitant orifice in eccentric FMR compared to that in eccentric DMR. This difference may explain the greater underestimation of effective regurgitant orifice area by the 2DPISA method in FMR. High-quality 3DTEE analysis of vena contracta area would be a highly recommended alternative. © 2017, Wiley Periodicals, Inc.
Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik
2015-12-01
After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.
Stamopoulos, Dimosthenis; Bakirtzi, Nerantzoula; Manios, Efthymios; Grapsa, Eirini
2013-01-01
Background In hemodialysis (HD) patients, anemia relates to three main factors: insufficient production of erythropoietin; impaired management of iron; and decreased lifespan of red blood cells (RBCs). The third factor can relate to structural deterioration of RBCs due to extrinsic (extracorporeal circuit; biochemical activation and/or mechanical stress during dialysis) and intrinsic (uremic milieu; biochemical interference of the RBC membrane constituents with toxins) mechanisms. Herein, we evaluate information accessed with advanced imaging techniques at the cellular level. Methods Atomic force and scanning electron microscopes were employed to survey intact RBCs (iRBCs) of seven HD patients in comparison to seven healthy donors. The extrinsic factor was investigated by contrasting pre- and post-HD samples. The intrinsic environment was investigated by comparing the microscopy data with the clinical ones. Results The iRBC membranes of the enrolled HD patients were overpopulated with orifice-like (high incidence; typical size within 100–1,000 nm) and crevice-like (low incidence; typical size within 500–4,000 nm) defects that exhibited a statistically significant (P < 0.05) relative increase (+55% and +350%, respectively) in respect to healthy donors. The relative variation of the orifice and crevice indices (mean population of orifices and crevices per top membrane surface) between pre- and post-HD was not statistically significant (−3.3% and +4.5%, respectively). The orifice index correlates with the concentrations of urea, calcium, and phosphorus, but not, however, with that of creatinine. Conclusion Extracorporeal circulation is not detrimental to the structural integrity of RBC membranes. Uremic milieu is a candidate cause of RBC membrane deterioration, which possibly worsens anemia. PMID:24143093
Comparison of Gas Displacement based on Thermometry in the Pulse Tube with Rayleigh Scattering
NASA Astrophysics Data System (ADS)
Hagiwara, Yasumasa; Nara, Kenichi; Ito, Seitoku; Saito, Takamoto
A pulse tube refrigerator has high reliability because of its simple structure. Recently the level of development activity of the pulse tube refrigerator has increased, but the quantitative understanding of the refrigeration mechanism has not fully been obtained. Therefore various explanations were proposed. The concept of virtual gas piston in particular helps us to understand the function of a phase shifter such as a buffer tank and an orifice because the virtual gas piston corresponds to a piston of a Stirling refrigerator. However it is difficult to directly measure the averaged gas displacement which corresponds to the virtual gas piston because uniform gas flow such as a gas piston does not always exist. For example, there are a jet flow from orifice and circulated flows in a pulse tube, which are predicted theoretically. In spite of these phenomena, the averaged gas displacement is very important in practical use because it can simply predict the performance from the displacement. In this report, we calculate the averaged gas displacement and mass flow through an orifice. The mass flow is calculated from the pressure change in a buffer tank. The averaged gas displacement is calculated from temperature profiles in the pulse tube and the mass flow. It is necessary to measure temperature in the pulse tube as widely as possible in order to calculate the averaged gas displacement. We apply a method using the Rayleigh Scattering the thermometry in the pulse tube. With this method, it is possible to perform 2-dimensional measurement without disturbing the gas flow. By this method, the averaged gas displacements and the temperature profiles of basic and orifice types of refrigeration were compared.
Mahmoud Elsayed, Hani M; Hassan, Mohamed; Nagy, Michael; Amin, Alaaeldin; Elguindy, Ahmed; Wagdy, Kerolos; Yacoub, Magdi
2018-03-01
Neither two- nor three-dimensional (3D) planimetry of the mitral valve (MV) orifice takes the mitral commissures into account. Thus, if the commissures are not completely fused, the MV orifice will not be planar, and MV area (MVA) will be underestimated. The study aimed to validate a novel method for measurement of the MVA using a software that traces the MV orifice including the commissures. The study included 30 patients undergoing percutaneous balloon mitral valvuloplasty for severe rheumatic mitral stenosis. All performed 3D transesophageal echocardiography (TEE) immediately before the procedure. MVA was measured using the mitral valve navigation (MVN) software of the Philips Q-Lab 10.2 in a diastolic frame with maximum diastolic opening of the MV. Regular 3D planimetry of the MV orifice was also performed. Before balloon dilation, the MVA was calculated invasively using the Gorlin's formula. No significant difference was detected between MVN-derived MVA and Gorlin-derived MVA (0.98 cm 2 vs. 1.0 cm 2 , P = .33). A statistically significant difference was detected between Planimetry-derived MVA and Gorlin-derived MVA (0.8 cm 2 vs. 1.0 cm 2 , P < .001). There were significant linear correlations between MVN-derived MVA and Gorlin-derived MVA (r = .84, P < .001). Using Bland-Altman analysis, Gorlin-derived MVA showed better and relatively narrower limits of agreement with MVN-derived MVA than planimetry-derived MVA. Measurement of the MVA using the MVN method is feasible and is more correlated to the invasively measured MVA than the 3D planimetry method. This is the most accurate method of measuring the MVA that takes MV commissures into account. © 2017, Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oliveira, Jorge Luiz Goes; Passos, Julio Cesar; Verschaeren, Ruud
Two-phase flow measurements were carried out using a resistive void fraction meter coupled to a venturi or orifice plate. The measurement system used to estimate the liquid and gas mass flow rates was evaluated using an air-water experimental facility. Experiments included upward vertical and horizontal flow, annular, bubbly, churn and slug patterns, void fraction ranging from 2% to 85%, water flow rate up to 4000 kg/h, air flow rate up to 50 kg/h, and quality up to almost 10%. The fractional root mean square (RMS) deviation of the two-phase mass flow rate in upward vertical flow through a venturi platemore » is 6.8% using the correlation of Chisholm (D. Chisholm, Pressure gradients during the flow of incompressible two-phase mixtures through pipes, venturis and orifice plates, British Chemical Engineering 12 (9) (1967) 454-457). For the orifice plate, the RMS deviation of the vertical flow is 5.5% using the correlation of Zhang et al. (H.J. Zhang, W.T. Yue, Z.Y. Huang, Investigation of oil-air two-phase mass flow rate measurement using venturi and void fraction sensor, Journal of Zhejiang University Science 6A (6) (2005) 601-606). The results show that the flow direction has no significant influence on the meters in relation to the pressure drop in the experimental operation range. Quality and slip ratio analyses were also performed. The results show a mean slip ratio lower than 1.1, when bubbly and slug flow patterns are encountered for mean void fractions lower than 70%. (author)« less
Euro-NOTES Status Paper: from the concept to clinical practice.
Fuchs, K H; Meining, A; von Renteln, D; Fernandez-Esparrach, G; Breithaupt, W; Zornig, C; Lacy, A
2013-05-01
The concept of natural orifice transluminal endoscopic surgery (NOTES) consists of the reduction of access trauma by using a natural orifice access to the intra-abdominal cavity. This could possibly lead to less postoperative pain, quicker recovery from surgery, fewer postoperative complications, fewer wound infections, and fewer long-term problems such as hernias. The Euro-NOTES Foundation has organized yearly meetings to work on this concept to bring it safely into clinical practice. The aim of this Euro-NOTES status update is to assess the yearly scientific working group reports and provide an overview on the current clinical practice of NOTES procedures. After the Euro-NOTES meeting 2011 in Frankfurt, Germany, an analysis was started regarding the most important topics of the European working groups. All prospectively documented information was gathered from Euro-NOTES and D-NOTES working groups from 2007 to 2011. The top five topics were analyzed. The statements of the working group activities demonstrate the growing information and changing insights. The most important selected topics were infection issue, peritoneal access, education and training, platforms and new technology, closure, suture, and anastomosis. The focus on research topics changed over time. The principle of hybrid access has overcome the technical and safety limitations of pure NOTES. Currently the following NOTES access routes are established for several indications: transvaginal access for cholecystectomy, appendectomy and colon resections; transesophageal access for myotomy; transgastric access for full-thickness small-tumor resections; and transanal/transcolonic access for rectal and colon resections. NOTES and hybrid NOTES techniques have emerged for all natural orifices and were introduced into clinical practice with a good safety record. There are different indications for different natural orifices. Each technique has been optimized for the purpose of finding a safe and realistic solution to perform the procedure according to the specific indication.
Quaini, A; Canic, S; Glowinski, R; Igo, S; Hartley, C J; Zoghbi, W; Little, S
2012-01-10
This work presents a validation of a fluid-structure interaction computational model simulating the flow conditions in an in vitro mock heart chamber modeling mitral valve regurgitation during the ejection phase during which the trans-valvular pressure drop and valve displacement are not as large. The mock heart chamber was developed to study the use of 2D and 3D color Doppler techniques in imaging the clinically relevant complex intra-cardiac flow events associated with mitral regurgitation. Computational models are expected to play an important role in supporting, refining, and reinforcing the emerging 3D echocardiographic applications. We have developed a 3D computational fluid-structure interaction algorithm based on a semi-implicit, monolithic method, combined with an arbitrary Lagrangian-Eulerian approach to capture the fluid domain motion. The mock regurgitant mitral valve corresponding to an elastic plate with a geometric orifice, was modeled using 3D elasticity, while the blood flow was modeled using the 3D Navier-Stokes equations for an incompressible, viscous fluid. The two are coupled via the kinematic and dynamic conditions describing the two-way coupling. The pressure, the flow rate, and orifice plate displacement were measured and compared with numerical simulation results. In-line flow meter was used to measure the flow, pressure transducers were used to measure the pressure, and a Doppler method developed by one of the authors was used to measure the axial displacement of the orifice plate. The maximum recorded difference between experiment and numerical simulation for the flow rate was 4%, the pressure 3.6%, and for the orifice displacement 15%, showing excellent agreement between the two. Copyright © 2011 Elsevier Ltd. All rights reserved.
Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S
2009-01-01
Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.
Ionita, Ciprian N.; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M.; Hoffmann, K R.; Bednarek, D. R.; Rudin, S
2009-01-01
Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage. PMID:19763252
Nichols, J Tyler; Krueger, Paul S
2012-09-01
Recent results have demonstrated that pulsed-jet propulsion can achieve propulsive efficiency greater than that for steady jets when short, high frequency pulses are used, and the pulsed-jet advantage increases as Reynolds number decreases into the intermediate range (∼50). An important aspect of propulsive performance, however, is the vehicle configuration. The nozzle configuration influences the jet speed and, in the case of pulsed-jets, the formation of the vortex rings with each jet pulse, which have important effects on thrust. Likewise, the hull configuration influences the vehicle speed through its effect on drag. To investigate these effects, several flow inlet, nozzle, and hull tail configurations were tested on a submersible, self-propelled pulsed-jet vehicle ('Robosquid' for short) for jet pulse length-to-diameter ratios (L/D) in the range 0.5-6 and pulsing duty cycles (St(L)) of 0.2 and 0.5. For the configurations tested, the vehicle Reynolds number (Re(υ)) ranged from 25 to 110. In terms of propulsive efficiency, changing between forward and aft-facing inlets had little effect for the conditions considered, but changing from a smoothly tapered aft hull section to a blunt tail increased propulsive efficiency slightly due to reduced drag for the blunt tail at intermediate Re(υ). Sharp edged orifices also showed increased vehicle velocity and propulsive efficiency in comparison to smooth nozzles, which was associated with stronger vortex rings being produced by the flow contraction through the orifice. Larger diameter orifices showed additional gains in propulsive efficiency over smaller orifices if the rate of mass flow was matched with the smaller diameter cases, but using the same maximum jet velocity with the larger diameter decreased the propulsive efficiency relative to the smaller diameter cases.
An Experimental Study of Synthetic Jets from Rectangular Orifices
NASA Technical Reports Server (NTRS)
Milanovic, Ivana M.
2003-01-01
During the past two summers Professor Milanovic conducted Wind tunnel experiments on steady jets-in-cross-flow and synthetic jets. In her anticipated visit during the upcoming summer, she will continue and complete the research on synthetic jets involving 2-dimensional orifices of different aspect ratio as well as inclined slots. In addition, experiments will be conducted on pulsatile jets-in-cross-flow. The pulsation will be provided via an oscillating valve at controllable frequencies. The experiment will involve mainly hot-wire anemometer measurements in the low-speed wind tunnel. Overall goal will be to obtain database and investigate flow control strategies. The research will be of fundamental nature.
Ahn, Woojin; Dargar, Saurabh; Halic, Tansel; Lee, Jason; Li, Baichun; Pan, Junjun; Sankaranarayanan, Ganesh; Roberts, Kurt; De, Suvranu
2014-01-01
The first virtual-reality-based simulator for Natural Orifice Translumenal Endoscopic Surgery (NOTES) is developed called the Virtual Translumenal Endoscopic Surgery Trainer (VTESTTM). VTESTTM aims to simulate hybrid NOTES cholecystectomy procedure using a rigid scope inserted through the vaginal port. The hardware interface is designed for accurate motion tracking of the scope and laparoscopic instruments to reproduce the unique hand-eye coordination. The haptic-enabled multimodal interactive simulation includes exposing the Calot's triangle and detaching the gall bladder while performing electrosurgery. The developed VTESTTM was demonstrated and validated at NOSCAR 2013.
Control of Combustion-Instabilities Through Various Passive Devices
NASA Technical Reports Server (NTRS)
Frendi, Abdelkader; Nesman, Tom; Canabal, Francisco
2005-01-01
Results of a computational study on the effectiveness of various passive devices for the control of combustion instabilities are presented. An axi-symmetric combustion chamber is considered. The passive control devices investigated are, baffles, Helmholtz resonators and quarter-waves. The results show that a Helmholtz resonator with a smooth orifice achieves the best control results, while a baffle is the least effective for the frequency tested. At high sound pressure levels, the Helmholtz resonator is less effective. It is also found that for a quarter wave, the smoothness of the orifice has the opposite effect than the Helmholtz resonator, i.e. results in less control.
Flame Tube NOx Emissions Using a Lean-Direct-Wall-Injection Combustor Concept
NASA Technical Reports Server (NTRS)
Tacina, Robert R.; Wey, Changlie; Choi, Kyung J.
2001-01-01
A low-NOx emissions combustor concept has been demonstrated in flame tube tests. A lean-direct injection concept was used where the fuel is injected directly into the flame zone and the overall fuel-air mixture is lean. In this concept the air is swirled upstream of a venturi section and the fuel is injected radially inward into the air stream from the throat section using a plain-orifice injector. Configurations have two-, four-, or six-wall fuel injectors and in some cases fuel is also injected from an axially located simplex pressure atomizer. Various orifice sizes of the plain-orifice injector were evaluated for the effect on NOx. Test conditions were inlet temperatures up to 8 1 OK, inlet pressures up to 2760 kPa, and flame temperatures up to 2100 K. A correlation is developed relating the NOx emissions to inlet temperature, inlet pressure, fuel-air ratio and pressure drop. Assuming that 15 percent of the combustion air would be used for liner cooling and using an advanced engine cycle, for the best configuration, the NOx emissions using the correlation is estimated to be <75 percent of the 1996 ICAO standard.
Method for polymer synthesis in a reaction well
Brennan, Thomas M.
1998-01-01
A method of synthesis for building a polymer chain, oligonucleotides in particular, by sequentially adding monomer units to at least one solid support for growing and immobilizing a polymer chain thereon in a liquid reagent solution. The method includes the step of: A) depositing a liquid reagent in a reaction well (26) in contact with at least one solid support and at least one monomer unit of the polymer chain affixed to the solid support. The well (26) includes at least one orifice (74) extending into the well (26), and is of a size and dimension to form a capillary liquid seal to retain the reagent solution in the well (26) to enable polymer chain growth on the solid support. The method further includes the step of B) expelling the reagent solution from the well (26), while retaining the polymer chain therein. This is accomplished by applying a first gas pressure to the reaction well such that a pressure differential between the first gas pressure and a second gas pressure exerted on an exit (80) of the orifice (74) exceeds a predetermined amount sufficient to overcome the capillary liquid seal and expel the reagent solution from the well (26) through the orifice exit (80).
Method for polymer synthesis in a reaction well
Brennan, T.M.
1998-09-29
A method of synthesis is described for building a polymer chain, oligonucleotides in particular, by sequentially adding monomer units to at least one solid support for growing and immobilizing a polymer chain thereon in a liquid reagent solution. The method includes the step of: (A) depositing a liquid reagent in a reaction well in contact with at least one solid support and at least one monomer unit of the polymer chain affixed to the solid support. The well includes at least one orifice extending into the well, and is of a size and dimension to form a capillary liquid seal to retain the reagent solution in the well to enable polymer chain growth on the solid support. The method further includes the step of (B) expelling the reagent solution from the well, while retaining the polymer chain therein. This is accomplished by applying a first gas pressure to the reaction well such that a pressure differential between the first gas pressure and a second gas pressure exerted on an exit of the orifice exceeds a predetermined amount sufficient to overcome the capillary liquid seal and expel the reagent solution from the well through the orifice exit. 9 figs.
Liver transplantation with piggyback anastomosis using a linear stapler: a case report.
Akbulut, S; Wojcicki, M; Kayaalp, C; Yilmaz, S
2013-04-01
The so-called piggyback technique of liver transplantation (PB-LT) preserves the recipient's caval vein, shortening the warm ischemic time. It can be reduced even further by using a linear stapler for the cavocaval anastomosis. Herein, we have presented a case of a patient undergoing a side-to-side, whole-organ PB-LT for cryptogenic cirrhosis. Upper and lower orifices of the donor caval vein were closed at the back table using a running 5-0 polypropylene suture. Three stay sutures were then placed on caudal parts of both the recipient and donor caval with a 5-mm venotomies. The endoscopic linear stapler was placed upward through the orifices and fired. A second stapler was placed more cranially and fired resulting in a 8-9 cm long cavocavostomy. Some loose clips were flushed away from the caval lumen. The caval anastomosis was performed within 4 minutes; the time needed to close the caval vein stapler insertion orifices (4-0 polypropylene running suture) before reperfusion was 1 minute. All other anastomoses were performed as typically sutured. The presented technique enables one to reduce the warm ischemic time, which can be of particular importance with marginal grafts. Copyright © 2013 Elsevier Inc. All rights reserved.
Benatta, Mohammed Amine
2018-01-01
This study focused on endoscopic examination of a prominent papilla which showed two separate orifices revealing separate entrance of the main pancreatic duct and of the common bile duct (A). This was the most rare anatomoendoscopic variation, accounting for only 10% of retrograde cholangiopancreatographies using endoscopic approach (ERCP). However, it facilitated selective biliary catheterization (SBC) in our patient, as one might have expected. Papilla had a pseudo polypoid appearance and a biliary orifice (BO) at the right angle toward the duodenal wall; hence this was a more difficult approach than that via the pancreatic orifice (PO) which, on the other hand, required undesired pancreatic catheterization (B). As SBC was the approach we decided to adopt, the special techniques to consider in this particular case were: transpancreatic sphincterotomy (TPS) alone or TPS after implantation of a pancreatic stent (PS). We opted for the second technique (STP + PS) and we noticed that the implantation of a PS resulted in better BO visualization (C). We could perform SBC without recourse to TPS. In this specific case, as in other cases of difficult SBC in our practice, PS has proven effectiveness.
NASA Technical Reports Server (NTRS)
Florschuetz, L. W.; Metzger, D. E.; Su, C. C.; Isoda, Y.; Tseng, H. H.
1982-01-01
Two-dimensional arrays of circular air jets impinging on a heat transfer surface parallel to the jet orifice plate are considered. The jet flow, after impingement, is constrained to exit in a single direction along the channel formed by the jet orifice plate and the heat transfer surface. The configurations considered are intended to model those of interest in current and contemplated gas turbine airfoil midchord cooling applications. The effects of an initial crossflow which approaches the array through an upstream extension of the channel are considered. Flow distributions as well as heat transfer coefficients and adiabatic wall temperatures resolved to one streamwise hole spacing were measured as a function of the initial crossflow rate and temperature relative to the jet flow rate and temperature. Both Nusselt number profiles and dimensionless adiabatic wall temperature (effectiveness) profiles are presented and discussed. Special test results which show a significant reduction of jet orifice discharge coefficients owing to the effect of a confined crossflow are also presented, along with a flow distribution model which incorporates those effects. A nonuniform array flow distribution model is developed and validated.
Characteristic of flotation deinking using bio and synthetic surfactant at different air flow rate
NASA Astrophysics Data System (ADS)
Trismawati, Wardana, I. N. G.; Hamidi, Nurkholis; Sasongko, Mega Nur
2016-03-01
Flotation deinking has industrially applied but several problems keep unsolved because limitations have to compete with several variables present. Flotation deinking is multi variables process, so studying flotation deinking is still interesting. In this research, the amount of variables was reduced and focused to the performance comparison between flotation deinking of old newspaper (ONP) using biodegradable fatty acid of morinda citrifolia as the raw bio surfactant (RBS) and biodegradable fatty acid of palm oil that had been converted to be commercial surfactant (CS). The flotation was done at laboratory flotation cell equipped with orifice at different diameter (orifice number 20, 40 and 60) with adjustable airflow rate. Brightness and Effective Residual Ink Concentration (ERIC) of the deinked pulp were measured. The best results were achieved on orifice number 40 with the highest brightness of 41.96 °ISO and 40.96 °ISO when using CS and RBS respectively, and lowest ERIC of 896.82 ppm and 1001.72 ppm when using CS and RBS respectively. The percentage delta of deinking power characteristic between CS and RBS was 2.36% and 11.70% for brightness and ERIC, respectively.
Balanced Flow Metering and Conditioning: Technology for Fluid Systems
NASA Technical Reports Server (NTRS)
Kelley, Anthony R.
2006-01-01
Revolutionary new technology that creates balanced conditions across the face of a multi-hole orifice plate has been developed, patented and exclusively licensed for commercialization. This balanced flow technology simultaneously measures mass flow rate, volumetric flow rate, and fluid density with little or no straight pipe run requirements. Initially, the balanced plate was a drop in replacement for a traditional orifice plate, but testing revealed substantially better performance as compared to the orifice plate such as, 10 times better accuracy, 2 times faster (shorter distance) pressure recovery, 15 times less acoustic noise energy generation, and 2.5 times less permanent pressure loss. During 2004 testing at MSFC, testing revealed several configurations of the balanced flow meter that match the accuracy of Venturi meters while having only slightly more permanent pressure loss. However, the balanced meter only requires a 0.25 inch plate and has no upstream or downstream straight pipe requirements. As a fluid conditioning device, the fluid usually reaches fully developed flow within 1 pipe diameter of the balanced conditioning plate. This paper will describe the basic balanced flow metering technology, provide performance details generated by testing to date and provide implementation details along with calculations required for differing degrees of flow metering accuracy.
Echocardiographic features of the normofunctional Labcor-Santiago pericardial bioprosthesis.
Gonzalez-Juanatey, J R; Garcia-Bengoechea, J B; Vega, M; Rubio, J; Sierra, J; Duran, D; Amaro, A; Gil, M
1994-09-01
Echocardiography was performed in 94 patients with a total of 99 normally functioning Labcor-Santiago bioprostheses, 62 in the aortic and 37 in the mitral position. The following variables were measured: peak and mean transvalvular velocities, peak and mean instantaneous pressure gradients as calculated from the modified Bernoulli equation, pressure half-time, cardiac index, stroke volume and effective orifice area (using continuity and Hatle equations). Regurgitation patterns were sought by transthoracic echocardiography (all valves) and, for selected mitral bioprostheses, by transesophageal echocardiography. Calculated mean aortic pressure gradient ranged from six to 10 mmHg and calculated effective aortic orifice area increased with ring diameter, with means of 1.27 cm2 for the 19 mm valve and 2.58 cm2 for the 27 mm valve. For mitral bioprostheses, mean pressure gradient ranged from 3.0 to 4.5 mmHg and calculated effective orifice area from 2.27 to 2.73 cm2. Only central regurgitation was observed. The Labcor-Santiago pericardial bioprostheses created little resistance to forward flow. In the small aortic root their hemodynamic performance was as good or better than that of other currently available devices. It is hoped that this new design will contribute increased in vivo mechanical durability.
Development of Tasks and Evaluation of a Prototype Forceps for NOTES
Addis, Matthew; Aguirre, Milton; Haluck, Randy; Matthew, Abraham; Pauli, Eric; Gopal, Jegan
2012-01-01
Background and Objectives: Few standardized testing procedures exist for instruments intended for Natural Orifice Translumenal Endoscopic Surgery. These testing procedures are critical for evaluating surgical skills and surgical instruments to ensure sufficient quality. This need is widely recognized by endoscopic surgeons as a major hurdle for the advancement of Natural Orifice Translumenal Endoscopic Surgery. Methods: Beginning with tasks currently used to evaluate laparoscopic surgeons and instruments, new tasks were designed to evaluate endoscopic surgical forceps instruments. Results: Six tasks have been developed from existing tasks, adapted and modified for use with endoscopic instruments, or newly designed to test additional features of endoscopic forceps. The new tasks include the Fuzzy Ball Task, Cup Drop Task, Ring Around Task, Material Pull Task, Simulated Biopsy Task, and the Force Gauge Task. These tasks were then used to evaluate the performance of a new forceps instrument designed at Pennsylvania State University. Conclusions: The need for testing procedures for the advancement of Natural Orifice Translumenal Endoscopic Surgery has been addressed in this work. The developed tasks form a basis for not only testing new forceps instruments, but also for evaluating individual performance of surgical candidates with endoscopic forceps instruments. PMID:22906337
Characterization of ecofriendly polyethylene fiber from plastic bag waste
NASA Astrophysics Data System (ADS)
Soekoco, Asril S.; Noerati, Komalasari, Maya; Kurniawan, Hananto, Agus
2017-08-01
This paper presents the characterization of fiber morphology, fiber count and tenacity of polyethylene fiber which is made from plastic bag waste. Recycling plastic bag waste into textile fiber has not developed yet. Plastic bag waste was recycled into fiber by melt spinning using laboratory scale melt spinning equipment with single orifice nozzle and plunger system. The basic principle of melt spinning is by melting materials and then extruding it through small orifice of a spinning nozzle to form fibers. Diameter and cross section shape of Recycled polyethylene fiber were obtained by using scanning electron microscope (SEM) instrumentation. Linear density of the recycled fiber were analyzed by calculation using denier and dTex formulation and The mechanical strength of the fibers was measured in accordance with the ASTM D 3379-75 standard. The cross section of recycled fiber is circular taking the shape of orifice. Fiber count of 303.75 denier has 1.84 g/denier tenacity and fiber count of 32.52 has 3.44 g/denier tenacity. This conditions is affected by the growth of polymer chain alignment when take-up axial velocity become faster. Recycled polyethylene fiber has a great potential application in non-apparel textile.
NASA Astrophysics Data System (ADS)
Karamah, Eva F.; Ghaudenson, Rioneli; Amalia, Fitri; Bismo, Setijo
2017-11-01
This research aims to evaluate the performance of hybrid method of ozonation and hydrodynamic cavitation with orifice plate on E.coli bacteria disinfection. In this research, ozone dose, circulation flowrate, and disinfection method were varied. Ozone was produced by commercial ozonator with ozone dose of 64.83 mg/hour, 108.18 mg/hour, and 135.04 mg/hour. Meanwhile, hydrodynamic cavitation was generated by an orifice plate. The disinfection method compared in this research were: hydrodynamic cavitation, ozonation, and the combination of both. The best result on each method was achieved on the 60th minutes and with a circulation flowrate of 7 L/min. The hybrid method attained final concentration of 0 CFU/mL from the initial concentration of 2.10 × 105 CFU/mL. The ozonation method attained final concentration of 0 CFU/mL from the initial concentration of 1.32 × 105 CFU/mL. Cavitation method gives the least disinfection with final concentration of 5.20 × 104 CFU/mL from the initial concentration of 2.17 × 105 CFU/mL. In conclusion, hybrid method gives a faster and better disinfection of E.coli than each method on its own.
NASA Technical Reports Server (NTRS)
Woronowicz, Michael
2016-01-01
Analytical expressions for column number density (CND) are developed for optical line of sight paths through a variety of steady free molecule point source models including directionally-constrained effusion (Mach number M = 0) and flow from a sonic orifice (M = 1). Sonic orifice solutions are approximate, developed using a fair simulacrum fitted to the free molecule solution. Expressions are also developed for a spherically-symmetric thermal expansion (M = 0). CND solutions are found for the most general paths relative to these sources and briefly explored. It is determined that the maximum CND from a distant location through directed effusion and sonic orifice cases occurs along the path parallel to the source plane that intersects the plume axis. For the effusive case this value is exactly twice the CND found along the ray originating from that point of intersection and extending to infinity along the plume's axis. For sonic plumes this ratio is reduced to about 4/3. For high Mach number cases the maximum CND will be found along the axial centerline path. Keywords: column number density, plume flows, outgassing, free molecule flow.
McIlwain, Michael E.; Grant, Jonathan F.; Golenko, Zsolt; Wittstein, Alan D.
1985-01-15
An ignition device of the plasma jet type is disclosed. The device has a cylindrical cavity formed in insulating material with an electrode at one end. The other end of the cylindrical cavity is closed by a metal plate with a small orifice in the center which plate serves as a second electrode. An arc jumping between the first electrode and the orifice plate causes the formation of a highly-ionized plasma in the cavity which is ejected through the orifice into the engine cylinder area to ignite the main fuel mixture. Two improvements are disclosed to enhance the operation of the device and the length of the plasma plume. One improvement is a metal hydride ring which is inserted in the cavity next to the first electrode. During operation, the high temperature in the cavity and the highly excited nature of the plasma breaks down the metal hydride, liberating hydrogen which acts as an additional fuel to help plasma formation. A second improvement consists of a cavity insert containing a plurality of spaced, metal rings. The rings act as secondary spark gap electrodes reducing the voltage needed to maintain the initial arc in the cavity.
Formation of Micro-Scale Gas Pockets From Underwater Wall Orifices
NASA Astrophysics Data System (ADS)
Pereira, Francisco A.; Gharib, Morteza
2012-11-01
Our experiments examine the formation of micro-scale gas pockets from orifices on walls with hydrophilic and hydrophobic wetting properties. Bubble injection is operated in a liquid at rest at constant flow rate and in a quasi-static regime, and the mechanism of bubble growth is investigated through high speed recordings. The growth dynamics is studied in terms of orifice size, surface wetting properties and buoyancy sign. The bubble formation is characterized by an explosive growth, with a pressure wave that causes the bubble to take highly transient shapes in its very initial stages, before stabilizing as a sphere and growing at a relatively slow rate. In case of positive buoyancy, the bubble elongates with the formation of a neck before detaching from the wall. When buoyancy acts towards the wall, the bubble attaches to the wall and expands laterally with a moving contact line. In presence of hydrophobic surfaces, the bubble attaches immediately to the wall irrespective of buoyancy direction and takes a hemispherical shape, expanding radially along the surface. A force balance is outlined to explain the different figures. The work was performed by FAP while on leave from CNR-INSEAN, and is supported by the Office of Naval Research (ONR).
Microalgal cell disruption via ultrasonic nozzle spraying.
Wang, M; Yuan, W
2015-01-01
The objective of this study was to understand the effect of operating parameters, including ultrasound amplitude, spraying pressure, nozzle orifice diameter, and initial cell concentration on microalgal cell disruption and lipid extraction in an ultrasonic nozzle spraying system (UNSS). Two algal species including Scenedesmus dimorphus and Nannochloropsis oculata were evaluated. Experimental results demonstrated that the UNSS was effective in the disruption of microalgal cells indicated by significant changes in cell concentration and Nile red-stained lipid fluorescence density between all treatments and the control. It was found that increasing ultrasound amplitude generally enhanced cell disruption and lipid recovery although excessive input energy was not necessary for best results. The effect of spraying pressure and nozzle orifice diameter on cell disruption and lipid recovery was believed to be dependent on the competition between ultrasound-induced cavitation and spraying-generated shear forces. Optimal cell disruption was not always achieved at the highest spraying pressure or biggest nozzle orifice diameter; instead, they appeared at moderate levels depending on the algal strain and specific settings. Increasing initial algal cell concentration significantly reduced cell disruption efficiency. In all UNSS treatments, the effectiveness of cell disruption and lipid recovery was found to be dependent on the algal species treated.
Lin, Tong; Gong, Lan
2016-06-01
The aim of the study was to evaluate the morphological changes of meibomian glands (MGs) in primary blepharospasm (PBS) by in vivo laser scanning confocal microscopy (LSCM) and to investigate the correlations between clinical data of PBS and LSCM parameters of MGs. This prospective and case-control study recruited 30 consecutive PBS patients and 30 age- and gender-matched healthy controls. After questionnaire assessments of ocular surface disease index (OSDI), Jankovic rating scale, and blepharospasm disability index, all subjects underwent blink rate evaluation, tear film break-up time (TBUT), corneal fluorescein staining (CFS), Schirmer test, MG expressibility, meibum quality, MG dropout, and LSCM examination of the MGs. The main LSCM outcomes included the mean MG acinar area and density, orifice diameter, meibum secretion reflectivity, acinar irregularity, and inhomogeneity of interstice and acinar wall. The PBS patients had significantly higher blink rate, higher OSDI and CFS scores, lower TBUT and Schirmer test value, and worse MG expressibility than the controls (All P < 0.05), whereas meibum quality showed no difference (P > 0.05). The PBS patients showed lower values of MG acinar area, orifice diameter and meibum secretion reflectivity, and higher scores of acinar irregularity and inhomogeneity of interstices than the controls (All P < 0.05). For the PBS patients, the severity of blepharospasm evaluated by JCR scale was strong correlated with MG acinar area (P < 0.001), orifice diameter (P = 0.002), meibum secretion reflectivity (P = 0.002), and MG acinar irregularity (P = 0.013). The MG expressibility was significantly correlated to MG acinar area (P = 0.039), orifice diameter (P < 0.001), and MG acinar irregularity (P = 0.014). The OSDI score was moderate correlated with MG acinar irregularity (P = 0.016), whereas the TBUT value was positively correlated with MG acinar area (P = 0.045) and negatively correlated to MG acinar irregularity (P = 0.016). The CFS score was negatively correlated to MG orifice diameter (P = 0.008). The LSCM provided a noninvasive tool for in vivo histopathologic studies of MGs in PBS patients. The excessive constriction of lid muscles closely related to MG morphological alterations of PBS, which offered a new research approach to interpret the interactional mechanism between dry eye and PBS.
In vivo confocal microscopy of meibomian glands in primary blepharospasm
Lin, Tong; Gong, Lan
2016-01-01
Abstract The aim of the study was to evaluate the morphological changes of meibomian glands (MGs) in primary blepharospasm (PBS) by in vivo laser scanning confocal microscopy (LSCM) and to investigate the correlations between clinical data of PBS and LSCM parameters of MGs. This prospective and case–control study recruited 30 consecutive PBS patients and 30 age- and gender-matched healthy controls. After questionnaire assessments of ocular surface disease index (OSDI), Jankovic rating scale, and blepharospasm disability index, all subjects underwent blink rate evaluation, tear film break-up time (TBUT), corneal fluorescein staining (CFS), Schirmer test, MG expressibility, meibum quality, MG dropout, and LSCM examination of the MGs. The main LSCM outcomes included the mean MG acinar area and density, orifice diameter, meibum secretion reflectivity, acinar irregularity, and inhomogeneity of interstice and acinar wall. The PBS patients had significantly higher blink rate, higher OSDI and CFS scores, lower TBUT and Schirmer test value, and worse MG expressibility than the controls (All P < 0.05), whereas meibum quality showed no difference (P > 0.05). The PBS patients showed lower values of MG acinar area, orifice diameter and meibum secretion reflectivity, and higher scores of acinar irregularity and inhomogeneity of interstices than the controls (All P < 0.05). For the PBS patients, the severity of blepharospasm evaluated by JCR scale was strong correlated with MG acinar area (P < 0.001), orifice diameter (P = 0.002), meibum secretion reflectivity (P = 0.002), and MG acinar irregularity (P = 0.013). The MG expressibility was significantly correlated to MG acinar area (P = 0.039), orifice diameter (P < 0.001), and MG acinar irregularity (P = 0.014). The OSDI score was moderate correlated with MG acinar irregularity (P = 0.016), whereas the TBUT value was positively correlated with MG acinar area (P = 0.045) and negatively correlated to MG acinar irregularity (P = 0.016). The CFS score was negatively correlated to MG orifice diameter (P = 0.008). The LSCM provided a noninvasive tool for in vivo histopathologic studies of MGs in PBS patients. The excessive constriction of lid muscles closely related to MG morphological alterations of PBS, which offered a new research approach to interpret the interactional mechanism between dry eye and PBS. PMID:27281086
Investigation of nozzle flow and cavitation characteristics in a diesel injector.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Som, S.; Ramirez, A.; Aggarwal, S.
2010-04-01
Cavitation and turbulence inside a diesel injector play a critical role in primary spray breakup and development processes. The study of cavitation in realistic injectors is challenging, both theoretically and experimentally, since the associated two-phase flow field is turbulent and highly complex, characterized by large pressure gradients and small orifice geometries. We report herein a computational investigation of the internal nozzle flow and cavitation characteristics in a diesel injector. A mixture based model in FLUENT V6.2 software is employed for simulations. In addition, a new criterion for cavitation inception based on the total stress is implemented, and its effectiveness inmore » predicting cavitation is evaluated. Results indicate that under realistic diesel engine conditions, cavitation patterns inside the orifice are influenced by the new cavitation criterion. Simulations are validated using the available two-phase nozzle flow data and the rate of injection measurements at various injection pressures (800-1600 bar) from the present study. The computational model is then used to characterize the effects of important injector parameters on the internal nozzle flow and cavitation behavior, as well as on flow properties at the nozzle exit. The parameters include injection pressure, needle lift position, and fuel type. The propensity of cavitation for different on-fleet diesel fuels is compared with that for n-dodecane, a diesel fuel surrogate. Results indicate that the cavitation characteristics of n-dodecane are significantly different from those of the other three fuels investigated. The effect of needle movement on cavitation is investigated by performing simulations at different needle lift positions. Cavitation patterns are seen to shift dramatically as the needle lift position is changed during an injection event. The region of significant cavitation shifts from top of the orifice to bottom of the orifice as the needle position is changed from fully open (0.275 mm) to nearly closed (0.1 mm), and this behavior can be attributed to the effect of needle position on flow patterns upstream of the orifice. The results demonstrate the capability of the cavitation model to predict cavitating nozzle flows in realistic diesel injectors and provide boundary conditions, in terms of vapor fraction, velocity, and turbulence parameters at the nozzle exit, which can be coupled with the primary breakup simulation.« less
Slugging Flow of Water Draining from the Bottom of a Non-Vented Container
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charles W. Solbrig
2010-06-01
Experiments were run to observe the behavior of water exiting through an orifice at the bottom of an non-vented container. Initially, the container is nearly full of water with a small air space on top. Once the orifice was uncovered, the slugging rate and the drain rate of the water leaving the container were measured. Upon initially opening the orifice, water drains out until the air pressure above the water reduces enough that the air pressure drop from inside to outside of the container supports the water column and the water stops flowing. Air then enters the container through themore » orifice forming a bubble, which grows until it detaches and bubbles through the water to reach the air space. Once the bubble enters, this added air increases the pressure in the air space enough to allow the water to start flowing out again. This cycle of flow out, flow stoppage, air inflow, and bubble breakoff continues over and over until the hole is closed or the container empties. This is referred to as the “slugging cycle.” A mechanism is proposed to describe the slugging cycle which is modeled analytically. This paper presents the description of the experiments, data obtained, the mechanistic model, and comparison of the model to the experimental data. The model predicts outflow rates close to experimental values. Flow rates from non-vented containers are more than 10 to 20 less than vented containers. The bubbles which must enter the container periodically to increase the internal air pressure stop the water flow momentarily so are responsible for this large decrease in flow rate. Swirl induced in the non-vented container causes the flow rates to increase by a factor of two. The flow rate out of a non-vented container is independent of water height which is in direct contrast to a vented container where the flow rate is proportional to the square root of the water height. The constant rate is due to the container pressure. The higher the water level, the lower the air pressure is in the container. This analytical model requires input of the bubble size. The volume recommended is the volume of a cylinder with the base of the orifice area and length of 3.3 cm. Slugging rate varies only a small amount falling in the range to 2 to 4 cycles/sec. Preliminary work with other containers indicates larger containers, larger orifices and nozzle exit shapes produce higher specific flow rates. The standard multiphase flow equations could not be used to analyze this situation because the two phases are not interpenetrating. Instead one phase must fully stop before the other can flow. Interpenetrating phases allow can pass one another each affecting the other with friction and virtual mass. An interesting observation: The negative air pressure in the container is observable. It equals the water height.« less
An Investigation of the Characteristics of Steel Diaphragms for Automatic Fuel-Injection Valves
NASA Technical Reports Server (NTRS)
Joachim, W F
1926-01-01
This research on steel diaphragms was undertaken at the Langley Memorial Aeronautical Laboratory, as a part of a general investigation on fuel injection engines for aircraft. The work determined the load-deflection, load- deformation and hysteresis characteristics for single diaphragms having thicknesses from 0.00s inch to 0.012 inch, and for similar diaphragms tested in multiple having total thicknesses from 0.012 inch to 0.180 inch. The elastic limit loads and deflections, and rupture points of single diaphragms were also determined. Some work was done on diaphragms having central orifices in order to determine the effect of orifice diameter upon the load deflection characteristics.
Afebrile Pannus-Induced Blood Culture-Negative Mechanical Valve Endocarditis.
Matsukuma, Seiji; Eishi, Kiyoyuki; Tanigawa, Kazuyoshi; Miura, Takashi; Matsumaru, Ichiro; Hisatomi, Kazuki; Tsuneto, Akira
2016-12-01
The diagnosis of prosthetic valve endocarditis may be challenging in patients with an atypical clinical presentation. Virtually all infections associated with mechanical prosthetic valves are localized to the prosthesis-tissue junction at the sewing ring and are accompanied by tissue destruction around the prosthesis. Because the orifice of the mechanical prosthetic valve is made of metal and pyrolytic carbon, which do not enable the adherence of microorganisms, any vegetation originating from the interior of the valve orifice is usually rare. Here we present a rare case of pannus-induced mechanical prosthetic valve endocarditis that was difficult to diagnose. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Method and apparatus for water jet drilling of rock
Summers, David A.; Mazurkiewicz, Marian; Bushnell, Dwight J.; Blaine, James
1978-01-01
Rock drilling method and apparatus utilizing high pressure water jets for drilling holes of relatively small diameter at speeds significantly greater than that attainable with existing drilling tools. Greatly increased drilling rates are attained due to jet nozzle geometry and speed of rotation. The jet nozzle design has two orifices, one pointing axially ahead in the direction of travel and the second inclined at an angle of approximately 30.degree. from the axis. The two orifices have diameters in the ratio of approximately 1:2. Liquid jet velocities in excess of 1,000 ft/sec are used, and the nozzle is rotated at speeds up to 1,000 rpm and higher.
Measurements of Fuel Distribution Within Sprays for Fuel-Injection Engines
NASA Technical Reports Server (NTRS)
Lee, Dana W
1937-01-01
Two methods were used to measure fuel distribution within sprays from several types of fuel-injection nozzles. A small tube inserted through the wall of an air tight chamber into which the sprays were injected could be moved about inside the chamber. When the pressure was raised to obtain air densities of 6 and 14 atmospheres, some air was forced through the tube and the fuel that was carried with it was separated by absorbent cotton and weighed. Cross sections of sprays from plain, pintle, multiple-orifice, impinging-jets, centrifugal, lip, slit, and annular-orifice nozzles were investigated, at distances of 1, 3, 5, and 7 inches from the nozzles.
Pressure Fluctuations in a Common-Rail Fuel Injection System
NASA Technical Reports Server (NTRS)
Rothrock, A M
1931-01-01
This report presents the results of an investigation to determine experimentally the instantaneous pressures at the discharge orifice of a common-rail fuel injection system in which the timing valve and cut-off valve were at some distance from the automatic fuel injection valve, and also to determine the methods by which the pressure fluctuations could be controlled. The results show that pressure wave phenomena occur between the high-pressure reservoir and the discharge orifice, but that these pressure waves can be controlled so as to be advantageous to the injection of the fuel. The results also give data applicable to the design of such an injection system for a high-speed compression-ignition engine.
Laparoscopic sleeve gastrectomy for morbid obesity with natural orifice specimen extraction (NOSE).
Gunkova, P; Gunka, I; Zonca, P; Dostalik, J; Ihnat, P
2015-01-01
An experience with laparoscopic sleeve gastrectomy using the natural orifice specimen extraction (NOSE) technique. Bariatric surgery is nowadays the only long term effective obesity treatment method. Twenty one consecutive patients underwent laparoscopic sleeve gastrectomy with the use of natural orifice specimen extraction (NOSE) in the Surgical Clinic of Faculty Hospital Ostrava between May 2012 and August 2012. Inclusion criteria were the body mass index (BMI) higher than 35 kg/m2 or higher than 32 kg/m2 accompanied with relevant comorbidities. Among 21 patients in this series, there were three men (14.3%) and 18 women (85.7%). Their mean age was 40.9±10.2 years. Their mean preoperative BMI was 40.4±4.6 kg/m2. No patient had previous bariatric surgery, one patient had laparoscopic fundoplication. All operations were completed laparoscopically with no conversions to an open procedure. In two cases, laparoscopic cholecystectomy was performed and the gallbladder was extracted along with the gastric specimen by transgastric approach. Laparoscopic sleeve gastrectomy is a safe and effective bariatric procedure with low morbidity and mortality. Based on our initial experiences it could be an indication for NOSE with transgastric approach. Obese patients would benefit from this approach due to the elimination of wound complications (Tab. 2, Fig. 3, Ref. 22).
He, Guoxi; Liang, Yongtu; Li, Yansong; Wu, Mengyu; Sun, Liying; Xie, Cheng; Li, Feng
2017-06-15
The accidental leakage of long-distance pressurized oil pipelines is a major area of risk, capable of causing extensive damage to human health and environment. However, the complexity of the leaking process, with its complex boundary conditions, leads to difficulty in calculating the leakage volume. In this study, the leaking process is divided into 4 stages based on the strength of transient pressure. 3 models are established to calculate the leaking flowrate and volume. First, a negative pressure wave propagation attenuation model is applied to calculate the sizes of orifices. Second, a transient oil leaking model, consisting of continuity, momentum conservation, energy conservation and orifice flow equations, is built to calculate the leakage volume. Third, a steady-state oil leaking model is employed to calculate the leakage after valves and pumps shut down. Moreover, sensitive factors that affect the leak coefficient of orifices and volume are analyzed respectively to determine the most influential one. To validate the numerical simulation, two types of leakage test with different sizes of leakage holes were conducted from Sinopec product pipelines. More validations were carried out by applying commercial software to supplement the experimental insufficiency. Thus, the leaking process under different leaking conditions are described and analyzed. Copyright © 2017 Elsevier B.V. All rights reserved.
Internal erosion rates of a 10-kW xenon ion thruster
NASA Technical Reports Server (NTRS)
Rawlin, Vincent K.
1988-01-01
A 30 cm diameter divergent magnetic field ion thruster, developed for mercury operation at 2.7 kW, was modified and operated with xenon propellant at a power level of 10 kW for 567 h to evaluate thruster performance and lifetime. The major differences between this thruster and its baseline configuration were elimination of the three mercury vaporizers, use of a main discharge cathode with a larger orifice, reduction in discharge baffle diameter, and use of an ion accelerating system with larger acceleration grid holes. Grid thickness measurement uncertainties, combined with estimates of the effects of reactive residual facility background gases gave a minimum screen grid lifetime of 7000 h. Discharge cathode orifice erosion rates were measured with three different cathodes with different initial orifice diameters. Three potential problems were identified during the wear test: the upstream side of the discharge baffle eroded at an unacceptable rate; two of the main cathode tubes experienced oxidation, deformation, and failure; and the accelerator grid impingement current was more than an order of magnitude higher than that of the baseline mercury thruster. The charge exchange ion erosion was not quantified in this test. There were no measurable changes in the accelerator grid thickness or the accelerator grid hole diameters.
An Investigation of the Coefficient of Discharge of Liquids Through Small Round Orifices
NASA Technical Reports Server (NTRS)
Joachim, W F
1926-01-01
The work covered by this report was undertaken in connection with a general investigation of fuel injection engine principles as applied to engines for aircraft propulsion, the specific purpose being to obtain information on the coefficient of discharge of small round orifices suitable for use as fuel injection nozzles. Values for the coefficient were determined for the more important conditions of engine service such as discharge under pressures up to 8,000 pounds per square inch, at temperatures between 80 degrees and 180 degrees F. And into air compressed to pressures up to 1,000 pounds per square inch. The results show that the coefficient ranges between 0.62 and 0.88 for the different test conditions between 1,000 and 8,000 pounds per square inch hydraulic pressure. At lower pressures the coefficient increases materially. It is concluded that within the range of these tests and for hydraulic pressures above 1,000 pound per square inch the coefficient does not change materially with pressure or temperature; that it depends considerably upon the liquid, decreases with increase in orifice size, and increases in the case of discharge into compressed air until the compressed-air pressure equals approximately three-tenths of the hydraulic pressure, beyond which pressure ratio it remains practically constant.
Flow Coupling Effects in Jet-in-Crossflow Flowfields
NASA Technical Reports Server (NTRS)
Bain, D. B.; Smith, C. E.; Liscinsky, D. S.; Holdeman, J. D.
1996-01-01
The combustor designer is typically required to design liner orifices that effectively mix air jets with crossflow effluent. CFD combustor analysis is typically used in the design process; however the jets are usually assumed to enter the combustor with a uniform velocity and turbulence profile. The jet-mainstream flow coupling is usually neglected because of the computational expense. This CFD study was performed to understand the effect of jet-mainstream flow coupling, and to assess the accuracy of jet boundary conditions that are commonly used in combustor internal calculations. A case representative of a plenum-fed quick-mix section of a Rich Burn/Quick Mix/Lean Burn combustor (i.e. a jet-mainstream mass-flow ratio of about 3 and a jet-mainstream momentum-flux ratio of about 30) was investigated. This case showed that the jet velocity entering the combustor was very non-uniform, with a low normal velocity at the leading edge of the orifice and a high normal velocity at the trailing edge of the orifice. Three different combustor-only cases were analyzed with uniform inlet jet profile. None of the cases matched the plenum-fed calculations. To assess liner thickness effects, a thin-walled case was also analyzed. The CFD analysis showed the thin-walled jets had more penetration than the thick-walled jets.
Development of a Haptic Interface for Natural Orifice Translumenal Endoscopic Surgery Simulation
Dargar, Saurabh; Sankaranarayanan, Ganesh
2016-01-01
Natural orifice translumenal endoscopic surgery (NOTES) is a minimally invasive procedure, which utilizes the body’s natural orifices to gain access to the peritoneal cavity. The NOTES procedure is designed to minimize external scarring and patient trauma, however flexible endoscopy based pure NOTES procedures require critical scope handling skills. The delicate nature of the NOTES procedure requires extensive training, thus to improve access to training while reducing risk to patients we have designed and developed the VTEST©, a virtual reality NOTES simulator. As part of the simulator, a novel decoupled 2-DOF haptic device was developed to provide realistic force feedback to the user in training. A series of experiments were performed to determine the behavioral characteristics of the device. The device was found capable of rendering up to 5.62N and 0.190Nm of continuous force and torque in the translational and rotational DOF, respectively. The device possesses 18.1Hz and 5.7Hz of force bandwidth in the translational and rotational DOF, respectively. A feedforward friction compensator was also successfully implemented to minimize the negative impact of friction during the interaction with the device. In this work we have presented the detailed development and evaluation of the haptic device for the VTEST©. PMID:27008674
NASA Astrophysics Data System (ADS)
Yu, Roger Ho Zhen; Ismail, Mohd Azmi bin; Ramdan, Muhammad Iftishah; Mustaffa, Nur Musfirah binti
2017-03-01
Synthetic Jet generates turbulence flow in cooling the microelectronic devices. In this paper, the experiment investigation of the cooling performance of pneumatic synthetic jet with single slot rectangular orifices at low frequency motion is presented. The velocity profile at the end of the orifice was measured and used as characteristic performance of synthetic jet in the present study. Frequencies of synthetic jet and the compressed air pressure supplied to the pneumatic cylinder (1bar to 5bar) were the parameters of the flow measurement. The air velocity of the synthetic jet was measured by using anemometer air flow meter. The maximum air velocity was 0.5 m/s and it occurred at frequency motion of 8 Hz. The optimum compressed air supplied pressure of the synthetic jet study was 4 bar. The cooling performance of synthetic jet at several driven frequencies from 0 Hz to 8 Hz and heat dissipation between 2.5W and 9W were also investigate in the present study. The results showed that the Nusselt number increased and thermal resistance decreased with both frequency and Reynolds number. The lowest thermal resistance was 5.25°C/W and the highest Nusselt number was 13.39 at heat dissipation of 9W and driven frequency of 8Hz.
Fluid-Structure Interaction Analysis of Ruptured Mitral Chordae Tendineae.
Toma, Milan; Bloodworth, Charles H; Pierce, Eric L; Einstein, Daniel R; Cochran, Richard P; Yoganathan, Ajit P; Kunzelman, Karyn S
2017-03-01
The chordal structure is a part of mitral valve geometry that has been commonly neglected or simplified in computational modeling due to its complexity. However, these simplifications cannot be used when investigating the roles of individual chordae tendineae in mitral valve closure. For the first time, advancements in imaging, computational techniques, and hardware technology make it possible to create models of the mitral valve without simplifications to its complex geometry, and to quickly run validated computer simulations that more realistically capture its function. Such simulations can then be used for a detailed analysis of chordae-related diseases. In this work, a comprehensive model of a subject-specific mitral valve with detailed chordal structure is used to analyze the distinct role played by individual chordae in closure of the mitral valve leaflets. Mitral closure was simulated for 51 possible chordal rupture points. Resultant regurgitant orifice area and strain change in the chordae at the papillary muscle tips were then calculated to examine the role of each ruptured chorda in the mitral valve closure. For certain subclassifications of chordae, regurgitant orifice area was found to trend positively with ruptured chordal diameter, and strain changes correlated negatively with regurgitant orifice area. Further advancements in clinical imaging modalities, coupled with the next generation of computational techniques will enable more physiologically realistic simulations.
Fluid-Structure Interaction Analysis of Ruptured Mitral Chordae Tendineae
Toma, Milan; Bloodworth, Charles H.; Pierce, Eric L.; Einstein, Daniel R.; Cochran, Richard P.; Yoganathan, Ajit P.; Kunzelman, Karyn S.
2016-01-01
The chordal structure is a part of mitral valve geometry that has been commonly neglected or simplified in computational modeling due to its complexity. However, these simplifications cannot be used when investigating the roles of individual chordae tendineae in mitral valve closure. For the first time, advancements in imaging, computational techniques, and hardware technology make it possible to create models of the mitral valve without simplifications to its complex geometry, and to quickly run validated computer simulations that more realistically capture its function. Such simulations can then be used for a detailed analysis of chordae-related diseases. In this work, a comprehensive model of a subject-specific mitral valve with detailed chordal structure is used to analyze the distinct role played by individual chordae in closure of the mitral valve leaflets. Mitral closure was simulated for 51 possible chordal rupture points. Resultant regurgitant orifice area and strain change in the chordae at the papillary muscle tips were then calculated to examine the role of each ruptured chorda in the mitral valve closure. For certain subclassifications of chordae, regurgitant orifice area was found to trend positively with ruptured chordal diameter, and strain changes correlated negatively with regurgitant orifice area. Further advancements in clinical imaging modalities, coupled with the next generation of computational techniques will enable more physiologically realistic simulations. PMID:27624659
Lehmann, Kai S; Ritz, Jörg P; Wibmer, Andreas; Gellert, Klaus; Zornig, Carsten; Burghardt, Jens; Büsing, Martin; Runkel, Norbert; Kohlhaw, Kay; Albrecht, Roland; Kirchner, Tom G; Arlt, Georg; Mall, Julian W; Butters, Michael; Bulian, Dirk R; Bretschneider, Jörgen; Holmer, Christoph; Buhr, Heinz J
2010-08-01
To analyze patient outcome in the first 14 months of the German natural orifice translumenal endoscopic surgery (NOTES) registry (GNR). NOTES is a new surgical concept, which permits scarless intra-abdominal operations through natural orifices, such as the mouth, vagina, rectum, or urethra. The GNR was established as a nationwide outcome database to allow the monitoring and safe introduction of this technique in Germany. The GNR was designed as a voluntary database with online access. All surgeons in Germany who performed NOTES procedures were requested to participate in the registry. The GNR recorded demographical and therapy data as well as data on the postoperative course. A total of 572 target organs were operated in 551 patients. Cholecystectomies accounted for 85.3% of all NOTES procedures. All procedures were performed in female patients using transvaginal hybrid technique. Complications occurred in 3.1% of all patients, conversions to laparoscopy or open surgery in 4.9%. In cholecystectomies, institutional case volume, obesity, and age had substantial effect on conversion rate, operation length, and length of hospital stay, but no effect on complications. Despite the fact that NOTES has just recently been introduced, the technique has already gained considerable clinical application. Transvaginal hybrid NOTES cholecystectomy is a practicable and safe alternative to laparoscopic resection even in obese or older patients.
Sripathi, Vangipuram Canchi; Kumar, Ramarathnam Krishna; Balakrishnan, Komarakshi R
2004-03-01
This study aims to find the fundamental differences in the mechanism of opening and closing of a normal aortic valve and a valve with a stiff root, using a dynamic finite element model. A dynamic, finite element model with time varying pressure was used in this study. Shell elements with linear elastic properties for the leaflet and root were used. Two different cases were analyzed: (1) normal leaflets inside a compliant root, and (2) normal leaflets inside a stiff root. A compliant aortic root contributes substantially to the smooth and symmetrical leaflet opening with minimal gradients. In contrast, the leaflet opening inside a stiff root is delayed, asymmetric, and wrinkled. However, this wrinkling is not associated with increased leaflet stresses. In compliant roots, the effective valve orifice area can substantially increase because of increased root pressure and transvalvular gradients. In stiff roots this effect is strikingly absent. A compliant aortic root contributes substantially to smooth and symmetrical leaflet opening with minimal gradients. The compliance also contributes much to the ability of the normal aortic valve to increase its effective valve orifice in response to physiologic demands of exercise. This effect is strikingly absent in stiff roots.
Experimental investigation of cavitation induced air release
NASA Astrophysics Data System (ADS)
Kowalski, Karoline; Pollak, Stefan; Hussong, Jeanette
Variations in cross-sectional areas may lead to pressure drops below a critical value, such that cavitation and air release are provoked in hydraulic systems. Due to a relatively slow dissolution of gas bubbles, the performance of hydraulic systems will be affected on long time scales by the gas phase. Therefore predictions of air production rates are desirable to describe the system characteristics. Existing investigations on generic geometries such as micro-orifice flows show an outgassing process due to hydrodynamic cavitation which takes place on time scales far shorter than diffusion processes. The aim of the present investigation is to find a correlation between global, hydrodynamic flow characteristics and cavitation induced undissolved gas fractions generated behind generic flow constrictions such as an orifice or venturi tube. Experimental investigations are realised in a cavitation channel that enables an independent adjustment of the pressure level upstream and downstream of the orifice. Released air fractions are determined by means of shadowgraphy imaging. First results indicate that an increased cavitation activity leads to a rapid increase in undissolved gas volume only in the choking regime. The frequency distribution of generated gas bubble size seems to depend only indirectly on the cavitation intensity driven by an increase of downstream coalescence events due to a more densely populated bubbly flow.
Liquid droplet radiator program at the NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Presler, A. F.; Coles, C. E.; Diem-Kirsop, P. S.; White, K. A., III
1985-01-01
The NASA Lewis Research Center and the Air Force Rocket Propulsion Laboratory (AFRPL) are jointly engaged in a program for technical assessment of the Liquid Droplet Radiator (LDR) concept as an advanced high performance heat ejection component for future space missions. NASA Lewis has responsibility for the technology needed for the droplet generator, for working fluid qualification, and for investigating the physics of droplets in space; NASA Lewis is also conducting systems/mission analyses for potential LDR applications with candidate space power systems. For the droplet generator technology task, both micro-orifice fabrication techniques and droplet stream formation processes have been experimentally investigated. High quality micro-orifices (to 50 micron diameter) are routinely fabricated with automated equipment. Droplet formation studies have established operating boundaries for the generation of controlled and uniform droplet streams. A test rig is currently being installed for the experimental verification, under simulated space conditions, of droplet radiation heat transfer performance analyses and the determination of the effect radiative emissivity of multiple droplet streams. Initial testing has begun in the NASA Lewis Zero-Gravity Facility for investigating droplet stream behavior in microgravity conditions. This includes the effect of orifice wetting on jet dynamics and droplet formation. Results for both Brayton and Stirling power cycles have identified favorable mass and size comparisons of the LDR with conventional radiator concepts.
Adjustable steam producing flexible orifice independent of fluid pressure
NASA Technical Reports Server (NTRS)
Morrison, Andrew D. (Inventor)
1992-01-01
A self-adjusting choke for a fluids nozzle includes a membrane constructed of a single piece of flexible or elastic material. This flexible material is shaped to fit into the outlet of a nozzle. The body of the membrane has at least two flow channels, from one face to the other, which directs two streams of water to cross at the opening of the nozzle or at some point beyond. The elasticity and thickness of the membrane is selected to match the range of expected pressures and fluid velocities. The choke may have more than two flow channels, as long as they are aligned adjacent to one another and directed towards each other at the exit face. In a three orifice embodiment, one is directed upward, one is directed downward, and the one in the middle is directed forward. In this embodiment all three fluid streams intersect at some point past the nozzle opening. Under increased pressure the membrane will deform causing the orifices to realign in a more forward direction, causing the streams to intersect at a smaller angle. This reduces the force with which the separate streams impact each other, still allowing the separate streams to unify into a single stable spiralling stream in spite of the increased pressure.
Kayaalp, Cuneyt; Tardu, Ali; Yagci, Mehmet Ali; Sumer, Fatih
2015-07-01
The length of incisions on the abdominal wall directly correlates with wound-related morbidities and patient comfort. Both mini-laparoscopy (only ≤5-mm trocars) and natural orifice specimen extraction avoid larger abdominal incisions. This study described a new natural orifice translumenal endoscopic surgery (NOTES(®); American Society for Gastrointestinal Endoscopy [Oak Brook, IL] and Society of American Gastrointestinal and Endoscopic Surgeons [Los Angeles, CA]) cholecystectomy technique by combination of these two advanced laparoscopic techniques for cholelithiasis in patients who had prior laparoscopic Roux-en-Y gastric bypass (LRYGB) for obesity. Three patients (two males, one female; 39, 62, and 34 years old, respectively) were admitted with symptomatic cholelithiasis (multiple millimeter-sized gallstones), and all had previously had LRYGB. They were treated by mini-laparoscopic cholecystectomy using three 5-mm trocars. The gallbladder was removed through the dilated efferent limb of the jejunum, 5 cm distal from the gastrojejunostomy. Transjejunal extraction was performed under endoscopic guidance. The gallbladder in the jejenum was passed through the anastomosis and extracted with an endoscopic snare by the transoral way. The enterotomy was closed intracorporeally. There was no conversion or additional trocar requirement. All the procedures were completed successfully without problems. Respective operating times were 95, 75, and 120 minutes. Only 1 patient required postoperative analgesic; the others did not. The patients started to get a liquid diet on the night of surgery and were discharged on Days 1, 1, and 2, respectively, with normal diet recommendations. There were no morbidities. Mini-laparoscopic cholecystectomy is technically feasible in patients with previous LRYGB. Prior LRYGB was not an obstacle for transoral specimen extraction. The dilated efferent jejunal limb is a good alternative route for natural orifice specimen extraction. This report described the first natural orifice surgery through the small bowel.
NASA Technical Reports Server (NTRS)
Shastry, Rohit; Soulas, George C.
2016-01-01
The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.
Klumpner, Thomas T; Lange, Elizabeth M S; Ahmed, Heena S; Fitzgerald, Paul C; Wong, Cynthia A; Toledo, Paloma
2016-11-01
Programmed intermittent bolus injection of epidural anesthetic solution results in decreased anesthetic consumption and better patient satisfaction compared with continuous infusion, presumably by better spread of the anesthetic solution in the epidural space. It is not known whether the delivery speed of the bolus injection influences analgesia outcomes. The objective of this in vitro study was to determine the pressure generated by a programmed intermittent bolus pump at 4 infusion delivery speeds through open-ended, single-orifice and closed-end, multiorifice epidural catheters. In vitro observational study. Not applicable. Not applicable. A CADD-Solis Pain Management System v3.0 with Programmed Intermittent Bolus Model 2110 was connected via a 3-way adapter to an epidural catheter and a digital pressure transducer. Pressures generated by delivery speeds of 100, 175, 300, and 400 mL/h of saline solution were tested with 4 epidural catheters (2 single orifice and 2 multiorifice). These runs were replicated on 5 pumps. Analysis of variance was used to compare the mean peak pressures of each delivery speed within each catheter group (single orifice and multiorifice). Thirty runs at each delivery speed were performed with each type of catheter for a total of 240 experimental runs. Peak pressure increased with increasing delivery speeds in both catheter groups (P<.001). Peak pressures were higher with the multiorifice catheter compared with the single-orifice catheter at all delivery speeds (P<.001, for all). Using a pump designed for programmed intermittent infusion boluses, the delivery speed of saline solution through epidural catheters was directly related to the peak pressures. Future work should evaluate whether differences in the delivery speed of anesthetic solution into the epidural space correlate with differences in the duration and quality of analgesia during programmed intermittent epidural bolus delivery. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Holdeman, James D.
1991-01-01
Experimental and computational results on the mixing of single, double, and opposed rows of jets with an isothermal or variable temperature mainstream in a confined subsonic crossflow are summarized. The studies were performed to investigate flow and geometric variations typical of the complex 3-D flowfield in the dilution zone of combustion chambers in gas turbine engines. The principal observations from the experiments were that the momentum-flux ratio was the most significant flow variable, and that temperature distributions were similar (independent of orifice diameter) when the orifice spacing and the square-root of the momentum-flux ratio were inversely proportional. The experiments and empirical model for the mixing of a single row of jets from round holes were extended to include several variations typical of gas turbine combustors. Combinations of flow and geometry that gave optimum mixing were identified from the experimental results. Based on results of calculations made with a 3-D numerical model, the empirical model was further extended to model the effects of curvature and convergence. The principle conclusions from this study were that the orifice spacing and momentum-flux relationships were the same as observed previously in a straight duct, but the jet structure was significantly different for jets injected from the inner wall wall of a turn than for those injected from the outer wall. Also, curvature in the axial direction caused a drift of the jet trajectories toward the inner wall, but the mixing in a turning and converging channel did not seem to be inhibited by the convergence, independent of whether the convergence was radial or circumferential. The calculated jet penetration and mixing in an annulus were similar to those in a rectangular duct when the orifice spacing was specified at the radius dividing the annulus into equal areas.
NASA Technical Reports Server (NTRS)
Holdeman, James D. (Technical Monitor); Chiappetta, Louis, Jr.; Hautman, Donald J.; Ols, John T.; Padget, Frederick C., IV; Peschke, William O. T.; Shirley, John A.; Siskind, Kenneth S.
2004-01-01
The low emissions potential of a Rich-Quench-Lean (RQL) combustor for use in the High Speed Civil Transport (HSCT) application was evaluated as part of Work Breakdown Structure (WBS) 1.0.2.7 of the NASA Critical Propulsion Components (CPC) Program under Contract NAS3-27235. Combustion testing was conducted in cell 1E of the Jet Burner Test Stand at United Technologies Research Center. Specifically, a Rich-Quench-Lean combustor, utilizing reduced scale quench technology implemented in a quench vane concept in a product-like configuration (Product Module Rig), demonstrated the capability of achieving an emissions index of nitrogen oxides (NOx EI) of 8.5 gm/Kg fuel at the supersonic flight condition (relative to the program goal of 5 gm/Kg fuel). Developmental parametric testing of various quench vane configurations in the more fundamental flametube, Single Module Rig Configuration, demonstrated NOx EI as low as 5.2. All configurations in both the Product Module Rig configuration and the Single Module Rig configuration demonstrated exceptional efficiencies, greater than 99.95 percent, relative to the program goal of 99.9 percent efficiency at supersonic cruise conditions. Sensitivity of emissions to quench orifice design parameters were determined during the parametric quench vane test series in support of the design of the Product Module Rig configuration. For the rectangular quench orifices investigated, an aspect ratio (length/width) of approximately 2 was found to be near optimum. An optimum for orifice spacing was found to exist at approximately 0.167 inches, resulting in 24 orifices per side of a quench vane, for the 0.435 inch quench zone channel height investigated in the Single Module Rig. Smaller quench zone channel heights appeared to be beneficial in reducing emissions. Measurements were also obtained in the Single Module Rig configuration on the sensitivity of emissions to the critical combustor parameters of fuel/air ratio, pressure drop, and residence time. Minimal sensitivity was observed for all of these parameters.
NASA Astrophysics Data System (ADS)
Melikhov, V. I.; Melikhov, O. I.; Nerovnov, A. A.; Nikonov, S. M.
2018-01-01
Processing of experimental data on the pressure difference across a submerged perforated sheet (SPS) revealed that, at sufficiently high void fractions under SPS, the pressure difference across it became less than the pressure difference for the pure steam stream with the same flowrate. To find the cause of this, the effect of a liquid film, which can be formed on the SPS upstream surface as a result of water droplets' impact and can smooth over sharp edges of holes in SDS, was examined. This can decrease the pressure drop across the sharp edges of holes. This assumption was checked through numerical solution to several model problems in the axisymmetric formulation for a steam flow in a round pipe with an orifice. The flow of steam and water was modeled using the viscous incompressible liquid approximation, while the turbulence was described by the k-ɛ model. The evolution of the interfacial area was modeled using the VOF model. The following model problems of steam flow through an orifice were studied: a single-phase flow, a flow through the orifice with a liquid film on its upstream surface, a flow through a chamfered hole, and a flow through the orifice with a liquid film on its upstream surface without liquid supply to the film. The predictions demonstrate that even the approximate account of the liquid film effect on the steam flow yields a considerable decrease in the pressure drop across the hole (from 8 to 24%) due to smoothing its sharp outlet edges over. This makes it possible to make a conclusion that the cause of a decrease in the pressure drop across SPS observed in the experiments at high void fractions is the formation of a liquid film, which smooths the sharp edges of the hole.
Ji, Chenyang; Zhang, Jinming; An, Geng; Liang, Weiqiang; Pan, Shujuan; Chen, Yuhong; Wei, Zhe; Zhang, Ganlin
2012-06-01
After patients with congenital microtia receive external ear canal plasty, the mastoid area usually has insufficient space for ear reconstruction. Hence, after ear reconstruction, an inferoposterior position deformity of the ear appears to some extent. Using inverted U-shaped purse and rotation flaps can correct this deformity effectively. From May of 2009 to September of 2011, five patients received the described procedures in the authors' department. Inverted U-shaped purse and rotation flaps were used for all the patients. The inverted U-shaped purse flap was used to reduce the area of the canal orifice and to lower the position, and the rotation flap was applied to turn the ear in a more superoposterior position. Two patients also received full-thickness skin grafting to cover the secondary wound. In four patients, V-Y-plasty or Z-plasty was used to adjust the flap transition. For the five patients, the distances between the ear antihelix and canal orifice were shortened, and the areas of the canal orifice were diminished. The retroversion of the auricle was corrected in various degrees, and the angles of the long axis of the auricle and the horizontal line were increased an average of 14.4°. The vertical distance between the top of the helix and the center of the canal orifice was increased an average of 15.2 mm. A slight dog ear deformity in front of the crus of the helix was left after the operation, but it was alleviated in the follow-up period. By using inverted U-shaped purse and rotation flaps, the inferoposterior position deformity of the reconstructed ear after external ear canal plasty in congenital microtia can be resolved effectively. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266.
Söylemez, Haluk; Yıldırım, Kadir; Utangac, Mehmet Mazhar; Aydoğan, Tahsin Batuhan; Ezer, Mehmet; Atar, Murat
2016-06-01
To investigate the effectivity of 4.5F ultrathin ureteroscope (UT-URS) without any need for active or passive dilation in the treatment of adult patient population in whom ureteral orifices cannot be engaged using conventional URS. Among a total of 512 adult patients who had undergone URS between April 2012 and November 2015 in our department for diagnostic or therapeutic purposes, 43 (8.4%) patients required ureteral dilation because we could not engage ureteral orifice. In adult patients in whom we could not engage ureteral orifice with 7.5F and 8F semirigid URS, we tried to complete the operation using 4.5F UT-URS without resorting to dilation. Age and gender of the patients, indication for operation, stone size, location, operative times, laterality of stone(s), stone-free rates, length of hospital stay, and complications were recorded. Mean age of the patients was 34.5 ± 11.2 (21-66) years. The patients had undergone operations for ureteral stone (n = 39), unexplained hydronephrosis (n = 2), and ureteral stenosis (n = 2). Mean stone size was 8.2 ± 2.3 (4-18) mm. Mean operative time was 64.2 ± 13.5 minutes. In 37 of 39 patients, a complete stone-free rate (94.8%) was achieved. Mean length of hospital stay was 8.9 ± 5.8 hours. It has been demonstrated that in an adult patient population in whom ureteral orifices cannot be engaged using conventional URS, ureteral access could be achieved with 4.5F UT-URS without any need for dilation. At the same time, use of 4.5F UT-URS resulted in an acceptable treatment success and lower complication rates in most of these patients without the need for a second session.
Little, Stephen H.; Igo, Stephen R.; Pirat, Bahar; McCulloch, Marti; Hartley, Craig J.; Nosé, Yukihiko; Zoghbi, William A.
2012-01-01
The 2-dimensional (2D) color Doppler (2D-CD) proximal isovelocity surface area (PISA) method assumes a hemispheric flow convergence zone to estimate transvalvular flow. Recently developed 3-dimensional (3D)-CD can directly visualize PISA shape and surface area without geometric assumptions. To validate a novel method to directly measure PISA using real-time 3D-CD echocardiography, a circulatory loop with an ultrasound imaging chamber was created to model mitral regurgitation (MR). Thirty-two different regurgitant flow conditions were tested using symmetric and asymmetric flow orifices. Three-dimensional–PISA was reconstructed from a hand-held real-time 3D-CD data set. Regurgitant volume was derived using both 2D-CD and 3D-CD PISA methods, and each was compared against a flowmeter standard. The circulatory loop achieved regurgitant volume within the clinical range of MR (11 to 84 ml). Three-dimensional–PISA geometry reflected the 2D geometry of the regurgitant orifice. Correlation between the 2D-PISA method regurgitant volume and actual regurgitant volume was significant (r2 = 0.47, p <0.001). Mean 2D-PISA regurgitant volume underestimate was 19.1 ± 25 ml (2 SDs). For the 3D-PISA method, correlation with actual regurgitant volume was significant (r2 = 0.92, p <0.001), with a mean regurgitant volume underestimate of 2.7 ± 10 ml (2 SDs). The 3D-PISA method showed less regurgitant volume underestimation for all orifice shapes and regurgitant volumes tested. In conclusion, in an in vitro model of MR, 3D-CD was used to directly measure PISA without geometric assumption. Compared with conventional 2D-PISA, regurgitant volume was more accurate when derived from 3D-PISA across symmetric and asymmetric orifices within a broad range of hemodynamic flow conditions. PMID:17493476
Brandt, D.
1984-06-05
An apparatus for preventing oxidation by uniformly distributing inert shielding gas over the weld area of workpieces such as pipes being welded together. The apparatus comprises a chamber and a gas introduction element. The chamber has an annular top wall, an annular bottom wall, an inner side wall and an outer side wall connecting the top and bottom walls. One side wall is a screen and the other has a portion defining an orifice. The gas introduction element has a portion which encloses the orifice and can be one or more pipes. The gas introduction element is in fluid communication with the chamber and introduces inert shielding gas into the chamber. The inert gas leaves the chamber through the screen side wall and is dispersed evenly over the weld area.
Brandt, Daniel
1985-01-01
An apparatus for preventing oxidation by uniformly distributing inert shielding gas over the weld area of workpieces such as pipes being welded together. The apparatus comprises a chamber and a gas introduction element. The chamber has an annular top wall, an annular bottom wall, an inner side wall and an outer side wall connecting the top and bottom walls. One side wall is a screen and the other has a portion defining an orifice. The gas introduction element has a portion which encloses the orifice and can be one or more pipes. The gas introduction element is in fluid communication with the chamber and introduces inert shielding gas into the chamber. The inert gas leaves the chamber through the screen side wall and is dispersed evenly over the weld area.
NASA Technical Reports Server (NTRS)
Warshawsky, I.
1972-01-01
Total pressure in a calibration chamber is determined by measuring the force on a disk suspended in an orifice in the baseplate of the chamber. The disk forms a narrow annular gap with the orifice. A continuous flow of calibration gas passes through the chamber and annulus to a downstream pumping system. The ratio of pressures on the two faces of the disk exceeds 100:1, so that chamber pressure is substantially equal to the product of disk area and net force on the disk. This force is measured with an electrodynamometer that can be calibrated in situ with dead weights. Probable error in pressure measurement is plus or minus (0.5 microtorr + 0.6 percent).
NASA Technical Reports Server (NTRS)
Kelley, Anthony R.
2008-01-01
This viewgraph document reviews the Balanced Flow Measurement (BFM) and Conditioning Technology, and makes the case for this as the NASA Invention of the Year. The BFM technology makes use of a thin, multi-hole orifice plate with holes sized and placed per a unique set of equations. It produces mass flow, volumetric flow,kinelic energy,or momentum BALANCE across the face of the plate. The flow is proportional.to the square root of upstream to downstream differential pressure. Multiple holes lead to smoother pressure measurement. Measures and conditions or can limit fluid flow. This innovation has many uses in and out of NASA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, F.W.; Back, G.G.; Burns, R.E.
1986-11-04
Constant flow devices, which deliver a constant flow of liquid over a range of upstream and downstream pressures, have been suggested as an alternative to orifice plates for proportioning AFFF in SSN 21 fire-suppression systems. Operational and performance characteristics of two lightweight, inexpensive, commercially available constant-flow devices have significant advantages over orifice plates. Both models tested, however, showed performance degradation when subjected to simulated service conditions. A constant flow device with improved resistance to wear and to AFFF exposure is desirable. Since the constant-flow control devices tested improves proportioning efficiency but do not have optimum characteristics, investigation of improved devicesmore » or methods is recommended.« less
Method for removing solid particulate material from within liquid fuel injector assemblies
Simandl, R.F.; Brown, J.D.; Andriulli, J.B.; Strain, P.D.
1998-09-08
A method is described for removing residual solid particulate material from the interior of liquid fuel injectors and other fluid flow control mechanisms having or being operatively associated with a flow-regulating fixed or variable orifice. The method comprises the sequential and alternate introduction of columns of a non-compressible liquid phase and columns of a compressed gas phase into the body of a fuel injector whereby the expansion of each column of the gas phase across the orifice accelerates the liquid phase in each trailing column of the liquid phase and thereby generates turbulence in each liquid phase for lifting and entraining the solid particulates for the subsequent removal thereof from the body of the fuel injector. 1 fig.
Unjamming a granular hopper by vibration
NASA Astrophysics Data System (ADS)
Janda, A.; Maza, D.; Garcimartín, A.; Kolb, E.; Lanuza, J.; Clément, E.
2009-07-01
We present an experimental study of the outflow of a hopper continuously vibrated by a piezoelectric device. Outpouring of grains can be achieved for apertures much below the usual jamming limit observed for non-vibrated hoppers. Granular flow persists down to the physical limit of one grain diameter, a limit reached for a finite vibration amplitude. For the smaller orifices, we observe an intermittent regime characterized by alternated periods of flow and blockage. Vibrations do not significantly modify the flow rates both in the continuous and the intermittent regime. The analysis of the statistical features of the flowing regime shows that the flow time significantly increases with the vibration amplitude. However, at low vibration amplitude and small orifice sizes, the jamming time distribution displays an anomalous statistics.
Method for removing solid particulate material from within liquid fuel injector assemblies
Simandl, Ronald F.; Brown, John D.; Andriulli, John B.; Strain, Paul D.
1998-01-01
A method for removing residual solid particulate material from the interior of liquid fuel injectors and other fluid flow control mechanisms having or being operatively associated with a flow-regulating fixed or variable orifice. The method comprises the sequential and alternate introduction of columns of a non-compressible liquid phase and columns of a compressed gas phase into the body of a fuel injector whereby the expansion of each column of the gas phase across the orifice accelerates the liquid phase in each trailing column of the liquid phase and thereby generates turbulence in each liquid phase for lifting and entraining the solid particulates for the subsequent removal thereof from the body of the fuel injector.
Fry, W.A.
1962-05-29
A valve for high vacuum applications such as the CStellarator where chamber pressures as low as 2 x 10/sup -10/ mm Hg are necessary is designed with a line-of-sight path through the valve for visual inspection of the contents of reactants in such chambers. The valve comprises a turnable resilient metal ball having an aperture therethrough, means for selectively turning the ball to rotate the axis of its line-of-sight path, and soft, deformable opposing orifices that are movable relatively toward said ball to seal with opposite ball surfaces upon said movement of said axis of said line-of-sight path. The valve also includes a bellows seal connected between said orifices and internal actuating means that eliminates the requirement for gasketed turnable valve closing stems. (AEC)
NASA Technical Reports Server (NTRS)
Henry, M. W.; Wolf, H.; Siemers, Paul M., III
1988-01-01
The SEADS pressure data obtained from the Shuttle flight 61-C are analyzed in conjunction with the preflight database. Based on wind tunnel data, the sensitivity of the Shuttle Orbiter stagnation region pressure distribution to angle of attack and Mach number is demonstrated. Comparisons are made between flight and wind tunnel SEADS orifice pressure distributions at several points throughout the re-entry. It is concluded that modified Newtonian theory provides a good tool for the design of a flush air data system, furnishing data for determining orifice locations and transducer sizing. Ground-based wind tunnel facilities are capable of providing the correction factors necessary for the derivation of accurate air data parameters from pressure data.
ERIC Educational Resources Information Center
Physics Education, 1988
1988-01-01
Describes three experiments: (1) "Liquid Flow from Orifices"; (2) "Microcomputer-Controlled Investigation of Battery Discharge and Recovery"; and (3) "Measurement of the Speed of Sound." Drawings and diagrams accompany each. (RT)
NOViSE: a virtual natural orifice transluminal endoscopic surgery simulator.
Korzeniowski, Przemyslaw; Barrow, Alastair; Sodergren, Mikael H; Hald, Niels; Bello, Fernando
2016-12-01
Natural orifice transluminal endoscopic surgery (NOTES) is a novel technique in minimally invasive surgery whereby a flexible endoscope is inserted via a natural orifice to gain access to the abdominal cavity, leaving no external scars. This innovative use of flexible endoscopy creates many new challenges and is associated with a steep learning curve for clinicians. We developed NOViSE-the first force-feedback-enabled virtual reality simulator for NOTES training supporting a flexible endoscope. The haptic device is custom-built, and the behaviour of the virtual flexible endoscope is based on an established theoretical framework-the Cosserat theory of elastic rods. We present the application of NOViSE to the simulation of a hybrid trans-gastric cholecystectomy procedure. Preliminary results of face, content and construct validation have previously shown that NOViSE delivers the required level of realism for training of endoscopic manipulation skills specific to NOTES. VR simulation of NOTES procedures can contribute to surgical training and improve the educational experience without putting patients at risk, raising ethical issues or requiring expensive animal or cadaver facilities. In the context of an experimental technique, NOViSE could potentially facilitate NOTES development and contribute to its wider use by keeping practitioners up to date with this novel surgical technique. NOViSE is a first prototype, and the initial results indicate that it provides promising foundations for further development.
Spray Formation from a Charged Liquid Jet of a Dielectric Fluid
NASA Astrophysics Data System (ADS)
Doak, William; de Bellis, Victor; Chiarot, Paul; Microfluidics; Multiphase Flow Laboratory Team
2017-11-01
Atomization of a dielectric micro-jet is achieved via an electrohydrodynamic charge injection process. The atomizer is comprised of a grounded nozzle housing (ground electrode) and an internal probe (high voltage electrode) that is concentric with the emitting orifice. The internal probe is held at electric potentials ranging from 1-10 kV. A pressurized reservoir drives a dielectric fluid at a desired flow rate through the 100-micrometer diameter orifice. The fluid fills the cavity between the electrodes as it passes through the atomizer, impeding the transport of electrons. This process injects charge into the flowing fluid. Upon exiting the orifice, the emitted jet is highly charged and it deforms via a bending instability that is qualitatively similar to the behavior observed in the electrospinning of fibers. We observed bulging regions, or nodes, of highly charged fluid forming along the bent, rotating jet. These nodes separate into highly charged droplets that emit satellite droplets. The remaining ligaments break up due to capillarity in a process that produces additional satellites. All of the droplets possess a normal (inertial) and radial (electrically-driven) momentum component. The radial component is responsible for the formation of a conical spray envelope. Our research focuses on the jet, its break up, and the droplet dynamics of this system. This research supported by the American Chemical Society.
Parekh, Bandish; Irani, Rukshin S; Sathe, Sucheta; Hegde, Vivek
2014-05-01
Microbial contamination of the pulp space is one of the major factors associated with endodontic failure. Thus, in addition to a three dimentional apical filling a coronal seal for root canal fillings has been recommended. The present study was conducted to evaluate and compare the intra-orifice sealing ability of three experimental materials after obturation of the root canal system. Fourty single rooted mandibular premolars were decoronated, cleaned, shaped and obturated. Gutta-percha was removed to the depth of 3.5 mm from the orifice with a heated plugger. Ten specimens each were sealed with Light Cure Glass Ionomer Cement (LCGIC), Flowable Composite (Tetric N-Flow), and Light Cure Glass Ionomer Cement with Flowable Composite in Sandwich Technique along with a positive control respectively and roots submerged in Rhodamine-B dye in vacuum for one week. Specimens were longitudinally sectioned and leakage measured using a 10X stereomicroscope and graded for depth of leakage. According to the results of the present study LC GIC + Tetric N Flow demonstrated significantly better seal (P < 0.01) than LC GIC. However there was no statistically significant difference in leakage (P > 0.01) between Tetric N-Flow and LCGIC+Tetric N-Flow groups. In the current study LCGIC+Tetric N-Flow was found to be superior over other experimental materials as intra-orifice barriers.
NASA Astrophysics Data System (ADS)
Huang, Zhen; Shao, Yiming; Shiga, Seiichi; Nakamura, Hisao
1994-09-01
This paper presents a recent advance in the study of injection of fuel containing dissolved gas (IFCDG). Using diesel fuel containing dissolved CO2, experiments were performed under atmospheric conditions on a diesel hole-type nozzle and simple nozzles. The effects of gas concentration in the fuel, injection pressure and the nozzle L/D ratio were examined. In order to reveal the controlling mechanism of IFCDG, the orifice flow pattern, pressure characteristics and their effects were also investigated. The result shows that IFCDG can produce a parabolic-shaped spray pattern with good atomization, which suggests the existence of a new atomization mechanism. In terms of atomization, the beneficial effect of the IFCDG is obtained at the dissolved gas concentration above the transition and in the region of larger nozzle L/D ratio. However, under unfavorable conditions, IFCDG will lead to deterioration of atomization with coarse fuel droplets. It is found that the big difference of the orifice pressure characteristics caused by the variation of the nozzle L/D ratio has a dominant influence on the separation of the dissolved gas from the fuel inside the orifice and is verified to account for a dramatic change in the spray pattern and determine the effect of IFCDG. It is considered that the concept of IFCDG could be attractive in producing more efficient, clean engine and find use in a wide range of application.
Wakes, S J; Holdø, A E; Meares, A J
2002-01-04
Prevention of major disasters such as Piper Alpha is a concern of oil and gas companies when commissioning a new offshore superstructure. Safety studies are undertaken to identify potential major hazards, risks to personnel and that sufficient precautions have been employed to minimise these. Such an assessment will also include the consideration of the protection from gas leaks such as the optimum positions of gas leak detectors and startup safety procedures after a leak. This requires a comprehensive knowledge of the behaviour of the leaking hydrocarbons as they emerge from the leak into the area of concern. Such leaks are most likely to emanate from a high aspect ratio cross-sectional curved slot in a pipeline. This paper challenges the conventional view that it is sufficient to model such leaks as axisymmetric jets. This paper is therefore concerned with an experimental study carried out on a series of more realistic high aspect ratio cross-sectional jets issuing from a flange orifice. Both high quality photographs in both planes of the jets and some quantitative pressure data is examined for a high aspect ratio cross-sectional jet of air at pressures up to 4.136bar. The effect of changing aspect ratio, fluid pressure and orifice shape will be discussed and put into context with regard to how this relates to offshore analysis studies.
A novel percussion type droplet-on-demand generator
NASA Astrophysics Data System (ADS)
Hussain, Taaha; Patel, Priyesh; Balachandran, Ramanarayanan; Ladommatos, Nicos
2015-01-01
Numerous engineering applications require generation of droplets on demand which are of high uniformity and constant size. The common method to produce droplets is to drive liquid at high pressure through a small orifice/nozzle. The liquid stream disintegrates into small droplets. However this method normally requires large volumes of liquid and is not suitable for applications where single droplets of constant size is required. Such applications require droplet-on-demand generators which commonly employ piezoelectric or pneumatic actuation. It is well known that piezoelectric generators are hard to employ at high pressure and, high temperature applications, and the pneumatic generators often produce satellite (secondary) droplets. This paper describes the development of a novel percussion type droplet-on-demand generator, which overcomes some of the above difficulties and is capable of producing single droplets on demand. The generator consists of a cylindrical liquid filled chamber with a small orifice at the bottom. The top of the chamber is covered with a thin flexible metal disc. A small metal pin is employed to hammer/impact the top metal surface to generate a pressure pulse inside the liquid chamber. The movement and the momentum of the metal pin are controlled using a solenoid device. The pressure pulse generated overcomes the surface tension of the liquid meniscus at the exit of the orifice and ejects a single droplet. The work presented in this paper will demonstrate the capabilities of the droplet generator.
Effects of subglottal and supraglottal acoustic loading on voice production
NASA Astrophysics Data System (ADS)
Zhang, Zhaoyan; Mongeau, Luc; Frankel, Steven
2002-05-01
Speech production involves sound generation by confined jets through an orifice (the glottis) with a time-varying area. Predictive models are usually based on the quasi-steady assumption. This assumption allows the complex unsteady flows to be treated as steady flows, which are more effectively modeled computationally. Because of the reflective properties of the human lungs, trachea and vocal tract, subglottal and supraglottal resonance and other acoustic effects occur in speech, which might affect glottal impedance, especially in the regime of unsteady flow separation. Changes in the flow structure, or flow regurgitation due to a transient negative transglottal pressure, could also occur. These phenomena may affect the quasi-steady behavior of speech production. To investigate the possible effects of the subglottal and supraglottal acoustic loadings, a dynamic mechanical model of the larynx was designed and built. The subglottal and supraglottal acoustic loadings are simulated using an expansion in the tube upstream of the glottis and a finite length tube downstream, respectively. The acoustic pressures of waves radiated upstream and downstream of the orifice were measured and compared to those predicted using a model based on the quasi-steady assumption. A good agreement between the experimental data and the predictions was obtained for different operating frequencies, flow rates, and orifice shapes. This supports the validity of the quasi-steady assumption for various subglottal and supraglottal acoustic loadings.
Defibulation: A Visual Reference and Learning Tool.
Abdulcadir, Jasmine; Marras, Sandra; Catania, Lucrezia; Abdulcadir, Omar; Petignat, Patrick
2018-04-01
Female genital mutilation type III (infibulation) is achieved by narrowing the vaginal orifice by creating a covering seal, accomplished by cutting and appositioning the labia minora and/or labia majora, with or without clitoral excision. Infibulation is responsible for significant urogynecological, obstetrical, and psychosexual consequences that can be treated with defibulation (or de-infibulation), an operation that opens the infibulation scar, exposing the vulvar vestibule, vaginal orifice, external urethral meatus, and eventually the clitoris. This article provides a practical comprehensive, up-to-date visual learning tool on defibulation, with information on pre-operative, post-operative, and follow-up information. Abdulcadir J, Marras S, Catania L, et al. Defibulation: a visual reference and learning tool. J Sex Med 2018;15:601-611. Copyright © 2018 International Society for Sexual Medicine. All rights reserved.
NASA Technical Reports Server (NTRS)
Thornton, D. E.
1976-01-01
Tests were conducted in a 14 foot transonic wind tunnel to examine the feasibility of the auxiliary aerodynamic data system (AADS) for determining angles of attack and sideslip during boost flight. The model used was a 0.07 scale replica of the external tank forebody consisting of the nose portion and a 60 inch (full scale) cylindrical section of the ogive cylinder tangency point. The model terminated in a blunt base with a 320.0 inch diameter at external tank (ET) station 1120.37. Pressure data were obtained from five pressure orifices (one total and four statics) on the nose probe, and sixteen surface static pressure orifices along the ET forebody.
Brandt, D.
1985-12-31
An apparatus is disclosed for preventing oxidation by uniformly distributing inert shielding gas over the weld area of workpieces such as pipes being welded together. The apparatus comprises a chamber and a gas introduction element. The chamber has an annular top wall, an annular bottom wall, an inner side wall and an outer side wall connecting the top and bottom walls. One side wall is a screen and the other has a portion defining an orifice. The gas introduction element has a portion which encloses the orifice and can be one or more pipes. The gas introduction element is in fluid communication with the chamber and introduces inert shielding gas into the chamber. The inert gas leaves the chamber through the screen side wall and is dispersed evenly over the weld area. 3 figs.
Kierkegaard, Axel; Boij, Susann; Efraimsson, Gunilla
2010-02-01
Acoustic wave propagation in flow ducts is commonly modeled with time-domain non-linear Navier-Stokes equation methodologies. To reduce computational effort, investigations of a linearized approach in frequency domain are carried out. Calculations of sound wave propagation in a straight duct are presented with an orifice plate and a mean flow present. Results of transmission and reflections at the orifice are presented on a two-port scattering matrix form and are compared to measurements with good agreement. The wave propagation is modeled with a frequency domain linearized Navier-Stokes equation methodology. This methodology is found to be efficient for cases where the acoustic field does not alter the mean flow field, i.e., when whistling does not occur.
Long-life leak standard assembly
Basford, James A.; Mathis, John E.; Wright, Harlan C.
1982-01-01
The present invention is directed to a portable leak standard assembly which is capable of providing a stream of high-purity reference gas at a virtually constant flow rate over an extensive period of time. The leak assembly comprises a high pressure reservoir coupled to a metal leak valve through a valve-controlled conduit. A reproducible leak valve useful in this assembly is provided by a metal tube crimped with a selected pressure loading for forming an orifice in the tube with this orifice being of a sufficient size to provide the selected flow rate. The leak valve assembly is formed of metal so that it can be "baked-out" in a vacuum furnace to rid the reservoir and attendent components of volatile impurities which reduce the efficiency of the leak standard.
Dispersion of capillary waves in elliptical cylindrical jets
NASA Astrophysics Data System (ADS)
Amini, Ghobad; Dolatabadi, Ali
2011-11-01
In this work motion of a low speed liquid jet issuing from an elliptic orifice through the air is studied. Mathematical solution of viscous free-surface flow for this asymmetric geometry is simplified by using one-dimensional Cosserat (directed curve) equations which can be assumed as a low order form of Navier-Stokes equations for slender jets. Linear solution is performed and temporal and spatial dispersion equations are derived. Growth rate and phase speed of unstable and stable modes under various conditions are presented. The possibility of instability of asymmetric disturbances is studied too. With distance down the jet, major and minor axes are altered and finally jet breaks up due to capillary instability. The effect of jet velocity and viscosity and also orifice ellipticity on axis-switching and breakup is investigated.
Discharge ratings for control gates at Mississippi River lock and dam 12, Bellevue, Iowa
Heinitz, Albert J.
1986-01-01
The water level of the navigation pools on the Mississippi River are maintained by the operation of tainter and roller gates at the locks and dams. Discharge ratings for the gates on Lock and Dam 12, at Bellevue, Iowa, were developed from current-meter discharge measurements made in the forebays of the gate structures. Methodology is given to accurately compute the gate openings of the tainter gates. Discharge coefficients, in equations that express discharge as a function of tailwater head , forebay head, and height of gate opening, were determined for conditions of submerged-orifice and fee-weir flow. A comparison of the rating discharges to the hydraulic-model rating discharges is given for submerged orifice flow for the tainter and roller gates.
NASA Technical Reports Server (NTRS)
Baumbick, R. J.
1974-01-01
Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.
Pressure compensated flow control valve
Minteer, Daniel J.
1999-01-01
The invention is an air flow control valve which is capable of maintaining a constant flow at the outlet despite changes in the inlet or outlet pressure. The device consists of a shell assembly with an inlet chamber and outlet chamber separated by a separation plate. The chambers are connected by an orifice. Also located within the inlet chamber is a port controller assembly. The port controller assembly consists of a differential pressure plate and port cap affixed thereon. The cap is able to slide in and out of the orifice separating the inlet and outlet chambers. When the pressure differential is sufficient, the differential pressure plate rises or falls to maintain a constant air flow. Movement of the port controller assembly does not require the use of seals, diaphragms, tight tolerances, bushings, bearings, hinges, guides, or lubricants.
Long-life leak standard assembly. [Patent application
Basford, J.A.; Mathis, J.E.; Wright, H.C.
1980-11-12
The present invention is directed to a portable leak standard assembly which is capable of providing a stream of high-purity reference gas at a virtually constant flow rate over an extensive period of time. The leak assembly comprises a high pressure reservoir coupled to a metal leak valve through a valve-controlled conduit. A reproducible leak valve useful in this assembly is provided by a metal tube crimped with a selected pressure loading for forming an orifice in the tube with this orifice being of a sufficient size to provide the selected flow rate. The leak valve assembly is formed of metal so that it can be baked-out in a vacuum furnace to rid the reservoir and attendent components of volatile impurities which reduce the efficiency of the leak standard.
Injection dynamics of gelled propellants
NASA Astrophysics Data System (ADS)
Yoon, Changjin
Gel propellants have been recognized as attractive candidates for future propulsion systems due to the reduced tendency to spill and the energy advantages over solid propellants. One of strong benefits emphasized in gel propellant applications is a throttling capability, but the accurate flow control is more complicated and difficult than with conventional Newtonian propellants because of the unique rheological behaviors of gels. This study is a computational effort directed to enhance understanding of the injector internal flow characteristics for gel propellants under rocket injection conditions. In simulations, the emphasized rheology is a shear-thinning which represents a viscosity decrease with increasing a shear rate. It is described by a generalized Newtonian fluid constitutive equation and Carreau-Yasuda model. Using this rheological model, two injection schemes are considered in the present study: axially-fed and cross-fed injection for single-element and multi-element impinging injectors, respectively. An axisymmetric model is developed to describe the axially-fed injector flows and fully three-dimensional model is utilized to simulate cross-fed injector flows. Under axially-fed injection conditions investigated, three distinct modes, an unsteady, steady, and hydraulic flip mode, are observed and mapped in terms of Reynolds number and orifice design. In an unsteady mode, quasi-periodic oscillations occur near the inlet lip leading mass pulsations and viscosity fluctuations at the orifice exit. This dynamic behavior is characterized using a time-averaged discharge coefficient, oscillation magnitude and frequency by a parametric study with respect to an orifice design, Reynolds number and rheology. As a result, orifice exit flows for gel propellants appear to be significantly influenced by a viscous damping and flow resistance due to a shear thinning behavior and these are observed in each factors considered. Under conditions driven by a manifold crossflow, unsteady and asymmetric flow structures are revealed as a series of vortices generated from the unstable vena contracta. Here, flows are characterized by an orifice design, manifold/core injection velocity ratio, Reynolds number and rheology. A significant decrease of discharge coefficients is noted with increasing the manifold flow. As the manifold crossflow increases, stronger friction losses are exerted on the leeward, and lead to larger hydraulic losses across the injector. In addition, calculations show that discharge coefficients decrease and the unsteadiness is mitigated as the viscosity increases by fluid rheology variations. A larger and more distinct horseshoe vortex is observed, and pulsation magnitude and viscosity fluctuations are mitigated with increasing viscosity. The oscillation frequency, however, remains unchanged even though the viscosity curves at the high shear rate are modified. All these observations confirm the conclusion that the role of viscous damping and flow resistance is more critical in cross-fed injection conditions than in axially-fed one.
Surgery via natural orifices in human beings: yesterday, today, tomorrow.
Moris, Demetrios N; Bramis, Konstantinos J; Mantonakis, Eleftherios I; Papalampros, Efstathios L; Petrou, Athanasios S; Papalampros, Alexandros E
2012-07-01
We performed an evaluation of models, techniques, and applicability to the clinical setting of natural orifice surgery (mainly natural orifice transluminal endoscopic surgery [NOTES]) primarily in general surgery procedures. NOTES has attracted much attention recently for its potential to establish a completely alternative approach to the traditional surgical procedures performed entirely through a natural orifice. Beyond the potentially scar-free surgery and abolishment of dermal incision-related complications, the safety and efficacy of this new surgical technology must be evaluated. Studies were identified by searching MEDLINE, EMBASE, Cochrane Library, and Entrez PubMed from 2007 to February 2011. Most of the references were identified from 2009 to 2010. There were limitations as far as the population that was evaluated (only human beings, no cadavers or animals) was concerned, but there were no limitations concerning the level of evidence of the studies that were evaluated. The studies that were deemed applicable for our review were published mainly from 2007 to 2010 (see Methods section). All the evaluated studies were conducted only in human beings. We studied the most common referred in the literature orifices such as vaginal, oral, gastric, esophageal, anal, or urethral. The optimal access route and method could not be established because of the different nature of each procedure. We mainly studied procedures in the field of general surgery such as cholecystectomy, intestinal cancers, renal cancers, appendectomy, mediastinoscopy, and peritoneoscopy. All procedures were feasible and most of them had an uneventful postoperative course. A number of technical problems were encountered, especially as far as pure NOTES procedures are concerned, which makes the need of developing new endoscopic instruments, to facilitate each approach, undeniable. NOTES is still in the early stages of development and more robust technologies will be needed to achieve reliable closure and overcome technical challenges. Well-designed studies in human beings need to be conducted to determine the safety and efficacy of NOTES in a clinical setting. Among these NOTES approaches, the transvaginal route seems less complicated because it virtually eliminates concerns for leakage and fistulas. The transvaginal approach further favors upper-abdominal surgeries because it provides better maneuverability to upper-abdominal organs (eg, liver, gallbladder, spleen, abdominal esophagus, and stomach). The stomach is considered one of the most promising targets because this large organ, once adequately mobilized, can be transected easily with a stapler. The majority of the approaches seem to be feasible even with the equipment used nowadays, but to achieve better results and wider applications to human beings, the need to develop new endoscopic instruments to facilitate each approach is necessary. Copyright © 2012 Elsevier Inc. All rights reserved.
Viperous fangs: development and evolution of the venom canal.
Zahradnicek, Oldrich; Horacek, Ivan; Tucker, Abigail S
2008-01-01
Fangs are specialised long teeth that contain either a superficial groove (Gila monster, Beaded lizard, some colubrid snakes), along which the venom runs, or an enclosed canal (viperid, elapid and atractaspid), down which the venom flows inside the tooth. The fangs of viperid snakes are the most effective venom-delivery structures among vertebrates and have been the focus of scientific interests for more than 200 years. Despite this interest the questions of how the canal at the centre of the fang forms remains unresolved. Two different hypotheses have been suggested. The mainstream hypothesis claims that the venom-conducting canal develops by the invagination of the epithelial wall of the developing tooth germ. The sides of this invagination make contact and finally fuse to form the enclosed canal. The second hypothesis, known as the "brick chimney", claims the venom-conducting canal develops directly by successive dentine deposition as the tooth develops. The fang is thus built up from the tip to the base, without any folding of the tooth surface. In an attempt to cast further light on this subject the early development of the fangs was followed in a pit viper, Trimeresurus albolabris, using the expression of Sonic hedgehog (Shh). We demonstrate that the canal is indeed formed by an early folding event, resulting from an invagination of epithelial cells into the dental mesenchyme. The epithelial cells proliferate to enlarge the canal and then the cells die by apoptosis, forming an empty tube through which the poison runs. The entrance and discharge orifices at either end of the canal develop by a similar invagination but the initial width of the invagination is very different from that in the middle of the tooth, and is associated with higher proliferation. The two sides of the invaginating epithelium never come into contact, leaving the orifice open. The mechanism by which the orifices form can be likened to that observed in reptiles with an open groove along their fangs, such as the boomslang. It is thus tempting to speculate that the process of orifice formation in viperids represents the ancestral pleisomorphic state, and that enclosed canals developed by a change in the shape and size of the initial invagination.
Fundamental investigation of ARC interruption in gas flows
NASA Astrophysics Data System (ADS)
Benenson, D. M.; Frind, G.; Kinsinger, R. E.; Nagamatsu, H. T.; Noeske, H. O.; Sheer, R. E., Jr.
1980-07-01
Thermal recovery in gas blast interrupters is discussed. The thermal recovery process was investigated with physical and aerodynamic methods, typically using reduced size nozzles and short sinusoidal current pulses. Aerodynamic characterization of the cold flow fields in several different nozzle types included measurements of the pressure and flow fields, both steady-state and turbulent components, with special attention given to wakes and shock structures. Special schlieren techniques on DC arcs and high speed photography on arcs in orifice nozzles show that shock heating broadens the arc independent of turbulence effects and produces a poorly recovering downstream arc section. Measured recovery speeds in both orifice and convergent-divergent nozzles agree with predictions of several arc theories assuming turbulent power losses. However, data on post-zero currents and power loss show values much smaller than theoretical predictions. Hydrogen, deuterium, and methane were measured.
Ceramic 3D printed Joule Thomson mini cryocooler intended for HOT IR detectors
NASA Astrophysics Data System (ADS)
Shapiro, A.; Fraiman, L.; Parahovnik, A.
2017-05-01
Joule Thomson (JT) Cryocooler is a well-known technology which is widely used in research and industry. The cooling effect is achieved by isenthalpic expansion of the cooling gas in an orifice. A JT cooler has two basic components: a counter flow heat exchanger and an orifice. Due to the fact that the cooler has no moving parts and contains relatively simple components it is a great candidate for miniaturization, and realization with the new additive manufacturing technologies. In the current work we discuss the implementation of 3D ceramic printing as a possible fabrication technology for a JT cooler intended for cooling IR detectors operated at temperature of about 150K. In this paper we present a comprehensive analysis including coolant considerations, heat transfer calculations and realization of the cooler.
NASA Technical Reports Server (NTRS)
Holdeman, James D.
1991-01-01
Experimental and computational results on the mixing of single, double, and opposed rows of jets with an isothermal or variable temperature mainstream in a confined subsonic crossflow are summarized. The studies were performed to investigate flow and geometric variations typical of the complex 3D flowfield in the dilution zone of combustion chambers in gas turbine engines. The principal observations from the experiments were that the momentum-flux ratio was the most significant flow variable, and that temperature distributions were similar (independent of orifice diameter) when the orifice spacing and the square-root of the momentum-flux ratio were inversely proportional. The experiments and empirical model for the mixing of a single row of jets from round holes were extended to include several variations typical of gas turbine combustors.
Method of design for vertical oil shale retorting vessels and retorting therewith
Reeves, Adam A.
1978-01-03
A method of designing the gas flow parameters of a vertical shaft oil shale retorting vessel involves determining the proportion of gas introduced in the bottom of the vessel and into intermediate levels in the vessel to provide for lateral distribution of gas across the vessel cross section, providing mixing with the uprising gas, and determining the limiting velocity of the gas through each nozzle. The total quantity of gas necessary for oil shale treatment in the vessel may be determined and the proportion to be injected into each level is then determined based on the velocity relation of the orifice velocity and its feeder manifold gas velocity. A limitation is placed on the velocity of gas issuing from an orifice by the nature of the solid being treated, usually physical tests of gas velocity impinging the solid.
Droplet Breakup in Expansion-contraction Microchannels
Zhu, Pingan; Kong, Tiantian; Lei, Leyan; Tian, Xiaowei; Kang, Zhanxiao; Wang, Liqiu
2016-01-01
We investigate the influences of expansion-contraction microchannels on droplet breakup in capillary microfluidic devices. With variations in channel dimension, local shear stresses at the injection nozzle and focusing orifice vary, significantly impacting flow behavior including droplet breakup locations and breakup modes. We observe transition of droplet breakup location from focusing orifice to injection nozzle, and three distinct types of recently-reported tip-multi-breaking modes. By balancing local shear stresses and interfacial tension effects, we determine the critical condition for breakup location transition, and characterize the tip-multi-breaking mode quantitatively. In addition, we identify the mechanism responsible for the periodic oscillation of inner fluid tip in tip-multi-breaking mode. Our results offer fundamental understanding of two-phase flow behaviors in expansion-contraction microstructures, and would benefit droplet generation, manipulation and design of microfluidic devices. PMID:26899018
Autorino, Riccardo; Stein, Robert J; Lima, Estevão; Damiano, Rocco; Khanna, Rakesh; Haber, Georges-Pascal; White, Michael A; Kaouk, Jihad H
2010-05-01
Objective of this study is to provide an evidence-based analysis of the current status and future perspectives of scarless urological surgery. A PubMed search has been performed for all relevant urological literature regarding natural orifice transluminal endoscopic surgery (NOTES) and laparoendoscopic single-site surgery (LESS). In addition, experience with LESS and NOTES at our own institution has been considered. All clinical and investigative reports for LESS and NOTES procedures in the urological literature have been considered. A wide variety of clinical procedures in urology have been successfully completed by using LESS techniques. Thus far, experience with NOTES has largely been investigational, although early clinical reports are emerging. Further development of instrumentation and platforms is necessary for both techniques to become more widely adopted throughout the urological community.
Factors influencing the effective spray cone angle of pressure-swirl atomizers
NASA Astrophysics Data System (ADS)
Chen, S. K.; Lefebvre, A. H.; Rollbuhler, J.
1992-01-01
The spray cone angles produced by several simplex pressure-swirl nozzles are examined using three liquids whose viscosities range from 0.001 to 0.012 kg/ms (1 to 12 cp). Measurements of both the visible spray cone angle and the effective spray cone angle are carried out over wide ranges of injection pressure and for five different values of the discharge orifice length/diameter ratio. The influence of the number of swirl chamber feed slots on spray cone angle is also examined. The results show that the spray cone angle widens with increase in injection pressure but is reduced by increases in liquid viscosity and/or discharge orifice length/diameter ratio. Variation in the number of swirl chamber feed slots between one and three has little effect on the effective spray cone angle.
A review of pulse tube refrigeration
NASA Technical Reports Server (NTRS)
Radebaugh, Ray
1990-01-01
This paper reviews the development of the three types of pulse tube refrigerators: basic, resonant, and orifice types. The principles of operation are given. It is shown that the pulse tube refrigerator is a variation of the Stirling-cycle refrigerator, where the moving displacer is substituted by a heat transfer mechanism or by an orifice to bring about the proper phase shifts between pressure and mass flow rate. A harmonic analysis with phasors is described which gives reasonable results for the refrigeration power, yet is simple enough to make clear the processes which give rise to the refrigeration. The efficiency and refrigeration power are compared with those of other refrigeration cycles. A brief review is given of the research being done at various laboratories on both one- and two-stage pulse tubes. A preliminary assessment of the role of pulse tube refrigerators is discussed.
Combustor air flow control method for fuel cell apparatus
Clingerman, Bruce J.; Mowery, Kenneth D.; Ripley, Eugene V.
2001-01-01
A method for controlling the heat output of a combustor in a fuel cell apparatus to a fuel processor where the combustor has dual air inlet streams including atmospheric air and fuel cell cathode effluent containing oxygen depleted air. In all operating modes, an enthalpy balance is provided by regulating the quantity of the air flow stream to the combustor to support fuel cell processor heat requirements. A control provides a quick fast forward change in an air valve orifice cross section in response to a calculated predetermined air flow, the molar constituents of the air stream to the combustor, the pressure drop across the air valve, and a look up table of the orifice cross sectional area and valve steps. A feedback loop fine tunes any error between the measured air flow to the combustor and the predetermined air flow.
NASA Astrophysics Data System (ADS)
Habchi, Chawki; Bohbot, Julien; Schmid, Andreas; Herrmann, Kai
2015-12-01
In this paper, a comprehensive two-fluid model is suggested in order to compute the in-nozzle cavitating flow and the primary atomization of liquid jets, simultaneously. This model has been applied to the computation of a typical large marine Diesel injector. The numerical results have shown a strong correlation between the in-nozzle cavitating flow and the ensuing spray orientation and atomization. Indeed, the results have confirmed the existence of an off-axis liquid core. This asymmetry is likely to be at the origin of the spray deviation observed experimentally. In addition, the primary atomization begins very close to the orifice exit as in the experiments, and the smallest droplets are generated due to cavitation pocket shape oscillations located at the same side, inside the orifice.
A mandibular third molar with three mesial roots: a case report.
Plotino, Gianluca
2008-02-01
Although its most common configuration is 2 roots and 3 root canals, mandibular molars might have many different combinations. A case of unusual root canal morphology is presented to demonstrate anatomic variations in mandibular molars. Endodontic therapy was performed in a mandibular third molar with 3 separate mesial roots. The appearance of the pulp chamber floor revealed 4 separate canal orifices. Radiographically the 4 root canals ended in their own distinct foramen. Many reports deal with 3 orifices or 3 independent canals in the mesial root, but none described 3 mesial canals in 3 separate mesial roots, indicating a rare anatomic configuration. This report points out the importance of looking for additional canals and unusual canal morphology, because knowledge of their existence might occasionally enable clinicians to treat a case successfully that otherwise might have ended in failure.
Abumandour, Mohamed M A
2018-06-01
The focus of the present study is to provide a full morphological description of the oropharyngeal cavity of the house sparrow. The head of six birds was prepared for gross examination and by stereo and electron microscopy. The bifid lingual apex has multiple long, rostrally directed needle-like processes. The lateral border of the apex carries rostromedially directed needle-like processes. The dorsal lingual surface of the apex and body carries numerous caudomedially directed filiform papillae and many orifices of lingual salivary glands. The lingual body is divided into two parts: rostral and caudal. The caudal part is divided into two laterally elevated regions by a median groove, while the rostral part is bounded laterally by a rostrodorsally directed papillary row, which on SEM is formed from two rows. On SEM, the lingual root has many orifices of posterior salivary glands. The pharyngeal papillary row is located at the caudal border of the laryngeal mound, but this single papillary row is formed from two rows at SEM magnification. The laryngeal cleft continues caudally as a laryngeal fissure bounded by two longitudinal rows of caudally directed papillae; at high SEM magnification, this fissure is divided into two halves by a median ridge which carries caudally directed papillae on its posterior part. The choanal cleft proceeds rostrally by the median tubercle. There are a small number of orifices of palatine salivary glands. The morphological characters of the oropharyngeal cavity of the sparrow confirm its adaptation to surrounding environmental conditions and available food particles.
Multiple source/multiple target fluid transfer apparatus
Turner, Terry D.
1997-01-01
A fluid transfer apparatus includes: a) a plurality of orifices for connection with fluid sources; b) a plurality of orifices for connection with fluid targets; c) a set of fluid source conduits and fluid target conduits associated with the orifices; d) a pump fluidically interposed between the source and target conduits to transfer fluid therebetween; e) a purge gas conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass a purge gas under pressure; f) a solvent conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass solvent, the solvent conduit including a solvent valve; g) pump control means for controlling operation of the pump; h) purge gas valve control means for controlling operation of the purge gas valve to selectively impart flow of purge gas to the fluid source conduits, fluid target conduits and pump; i) solvent valve control means for controlling operation of the solvent valve to selectively impart flow of solvent to the fluid source conduits, fluid target conduits and pump; and j) source and target valve control means for controlling operation of the fluid source conduit valves and the fluid target conduit valves to selectively impart passage of fluid between a selected one of the fluid source conduits and a selected one of the fluid target conduits through the pump and to enable passage of solvent or purge gas through selected fluid source conduits and selected fluid target conduits.
Multiple source/multiple target fluid transfer apparatus
Turner, T.D.
1997-08-26
A fluid transfer apparatus includes: (a) a plurality of orifices for connection with fluid sources; (b) a plurality of orifices for connection with fluid targets; (c) a set of fluid source conduits and fluid target conduits associated with the orifices; (d) a pump fluidically interposed between the source and target conduits to transfer fluid there between; (e) a purge gas conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass a purge gas under pressure; (f) a solvent conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass solvent, the solvent conduit including a solvent valve; (g) pump control means for controlling operation of the pump; (h) purge gas valve control means for controlling operation of the purge gas valve to selectively impart flow of purge gas to the fluid source conduits, fluid target conduits and pump; (i) solvent valve control means for controlling operation of the solvent valve to selectively impart flow of solvent to the fluid source conduits, fluid target conduits and pump; and (j) source and target valve control means for controlling operation of the fluid source conduit valves and the fluid target conduit valves to selectively impart passage of fluid between a selected one of the fluid source conduits and a selected one of the fluid target conduits through the pump and to enable passage of solvent or purge gas through selected fluid source conduits and selected fluid target conduits. 6 figs.
Spray Characteristics of a Hybrid Twin-Fluid Pressure-Swirl Atomizer
NASA Technical Reports Server (NTRS)
Durham, M. J.; Sojka, P. E.; Ashmore, C. B.
2004-01-01
The spray performance of a fuel injection system applicable for use in main combustion chamber of an oxidizer-rich staged combustion (ORSC) cycles is presented. The experimental data reported here include mean drop size and drop size distribution, spray cone half-angle, and momentum rate (directly related to spray penetration). The maximum entropy formalism, MEF, method to predict drop size distribution is applied and compared to the experimental data. Geometric variables considered include the radius of the injector inlet orifice plate through which oxidizer flows (&) and the exposed length from the fuel inlet to the injector exit plane (L2). Operating conditions that were varied include the liquid mass flow rate and air mass flow rate. For orifices B and C there is a significant dependence of D3Z on both the air and liquid mass flow rates, as well as on L2. For the A orifice, the momentum rate of the air flow appears to exceed a threshold value above which a constant D32 is obtained. Using the MEF method, a semi-analytical process was developed to model the spray distribution using two input parameters (q = 0.4 and Dso). The momentum rate of the spray is directly related to the air and liquid mass flow rates. The cone half angle of the spray ranges from 25 to 17 degrees. The data resulting from this project will eventually be used to develop advanced rocket systems.
Multiple-orifice liquid injection into hypersonic airstreams and applications to ram C-3 flight
NASA Technical Reports Server (NTRS)
Weaver, W. L.
1972-01-01
Experimental data are presented for the oblique injection of water and three electrophilic liquids (fluorocarbon compounds) through multiple-orifice nozzles from a flat plate and the sides of a hemisphere-cone (0.375 scale of RAM C spacecraft) into hypersonic airstreams. The nozzle patterns included single and multiple orifices, single rows of nozzles, and duplicates of the RAM C-III nozzles. The flat-plate tests were made at Mach 8. Total pressure was varied from 3.45 MN/m2 to 10.34 MN/m2, Reynolds number was varied form 9,840,000 per meter to 19,700,000 per meter, and liquid injection pressure was varied from 0.69 MN/m2 to 3.5 MN/m2. The hemisphere-cone tests were made at Mach 7.3. Total pressure was varied from 1.38 MN/m2, to 6.89 MN/m2, Reynolds number was varied from 3,540,000 per meter to 17,700,000 per meter, and liquid-injection pressure was varied from 0.34 MN/m2 to 4.14 MN/m2. Photographs of the tests and plots of liquid-penetration and spray cross-section area are presented. Maximum penetration was found to vary as the square root of the dynamic-pressure ratio and the square root of the total injection nozzle area. Spray cross-section area was linear with maximum penetration. The test results are used to compute injection parameters for the RAM C-3 flight injection experiment.
Multimode-Optical-Fiber Imaging Probe
NASA Technical Reports Server (NTRS)
Jackson, Deborah
2000-01-01
Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (< 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. To solve this problem, this work describes an approach for recovering images from. tightly confined spaces using multimode fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).
Multimode-Optical-Fiber Imaging Probe
NASA Technical Reports Server (NTRS)
Jackson, Deborah
1999-01-01
Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside the orifices of the body. This limits their use to the larger natural orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example, can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (less than or equal to 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. This work describes an approach for recovering images from tightly confined spaces using multimode. The concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront, which was predistorted with the characteristics of the fiber. The approach described here also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually inaccessible).
Reactor for in situ measurements of spatially resolved kinetic data in heterogeneous catalysis
NASA Astrophysics Data System (ADS)
Horn, R.; Korup, O.; Geske, M.; Zavyalova, U.; Oprea, I.; Schlögl, R.
2010-06-01
The present work describes a reactor that allows in situ measurements of spatially resolved kinetic data in heterogeneous catalysis. The reactor design allows measurements up to temperatures of 1300 °C and 45 bar pressure, i.e., conditions of industrial relevance. The reactor involves reactants flowing through a solid catalyst bed containing a sampling capillary with a side sampling orifice through which a small fraction of the reacting fluid (gas or liquid) is transferred into an analytical device (e.g., mass spectrometer, gas chromatograph, high pressure liquid chromatograph) for quantitative analysis. The sampling capillary can be moved with μm resolution in or against flow direction to measure species profiles through the catalyst bed. Rotation of the sampling capillary allows averaging over several scan lines. The position of the sampling orifice is such that the capillary channel through the catalyst bed remains always occupied by the capillary preventing flow disturbance and fluid bypassing. The second function of the sampling capillary is to provide a well which can accommodate temperature probes such as a thermocouple or a pyrometer fiber. If a thermocouple is inserted in the sampling capillary and aligned with the sampling orifice fluid temperature profiles can be measured. A pyrometer fiber can be used to measure the temperature profile of the solid catalyst bed. Spatial profile measurements are demonstrated for methane oxidation on Pt and methane oxidative coupling on Li/MgO, both catalysts supported on reticulated α -Al2O3 foam supports.
Numerical Simulations of Instabilities in Single-Hole Office Elements
NASA Technical Reports Server (NTRS)
Ahuja, Vineet; Hosangadi, Ashvin; Hitt, Matthew A.; Lineberry, David M.
2013-01-01
An orifice element is commonly used in liquid rocket engine test facilities either as a flow metering device, a damper for acoustic resonance or to provide a large reduction in pressure over a very small distance in the piping system. While the orifice as a device is largely effective in stepping down pressure, it is also susceptible to a wake-vortex type instability that generates pressure fluctuations that propagate downstream and interact with other elements of the test facility resulting in structural vibrations. Furthermore in piping systems an unstable feedback loop can exist between the vortex shedding and acoustic perturbations from upstream components resulting in an amplification of the modes convecting downstream. Such was the case in several tests conducted at NASA as well as in the Ariane 5 strap-on P230 engine in a static firing test where pressure oscillations of 0.5% resulted in 5% thrust oscillations. Exacerbating the situation in cryogenic test facilities, is the possibility of the formation of vapor clouds when the pressure in the wake falls below the vapor pressure leading to a cavitation instability that has a lower frequency than the primary wake-vortex instability. The cavitation instability has the potential for high amplitude fluctuations that can cause catastrophic damage in the facility. In this paper high-fidelity multi-phase numerical simulations of an orifice element are used to characterize the different instabilities, understand the dominant instability mechanisms and identify the tonal content of the instabilities.
Extraordinary phase separation and segregation in vent fluids from the southern East Pacific Rise
Von Damm, Karen L.; Lilley, M.D.; Shanks, Wayne C.; Brockington, M.; Bray, A.M.; O'Grady, K. M.; Olson, E.; Graham, A.; Proskurowski, G.
2003-01-01
The discovery of Brandon vent on the southern East Pacific Rise is providing new insights into the controls on midocean ridge hydrothermal vent fluid chemistry. The physical conditions at the time ofsampling (287 bar and 405??C) place the Brandon fluids very close to the critical point of seawater (298 bar and 407??C). This permits in situ study of the effects of near criticalphenomena, which are interpreted to be the primary cause of enhanced transition metal transport in these fluids. Of the five orifices on Brandon sampled, three were venting fluids with less than seawater chlorinity, and two were venting fluids with greater than seawater chlorinity. The liquid phase orifices contain 1.6-1.9 times the chloride content of the vapors. Most other elements, excluding the gases, have this same ratio demonstrating the conservative nature of phase separation and the lack of subsequent water-rock interaction. The vapor and liquid phases vent at the same time from orifices within meters of each other on the Brandon structure. Variations in fluid compositions occur on a time scale of minutes. Our interpretation is that phase separation and segregation must be occurring 'real time' within the sulfide structure itself. Fluids from Brandon therefore provide an unique opportunity to understand in situ phase separation without the overprinting of continued water-rock interaction with the oceanic crust, as well as critical phenomena. ?? 2002 Elsevier Science B.V. All rights reserved.
Characterization of a hydro-pneumatic suspension strut with gas-oil emulsion
NASA Astrophysics Data System (ADS)
Yin, Yuming; Rakheja, Subhash; Yang, Jue; Boileau, Paul-Emile
2018-06-01
The nonlinear stiffness and damping properties of a simple and low-cost design of a hydro-pneumatic suspension (HPS) strut that permits entrapment of gas into the hydraulic oil are characterized experimentally and analytically. The formulation of gas-oil emulsion is studied in the laboratory, and the variations in the bulk modulus and mass density of the emulsion are formulated as a function of the gas volume fraction. An analytical model of the HPS is formulated considering polytropic change in the gas state, seal friction, and the gas-oil emulsion flows through orifices and valves. The model is formulated considering one and two bleed orifices configurations of the strut. The measured data acquired under a nearly constant temperature are used to identify gas volume fraction of the emulsion, and friction and flow discharge coefficients as functions of the strut velocity and fluid pressure. The results suggested that single orifice configuration, owing to high fluid pressure, causes greater gas entrapment within the oil and thus significantly higher compressibility of the gas-oil emulsion. The model results obtained under different excitations in the 0.1-8 Hz frequency range showed reasonably good agreements with the measured stiffness and damping properties of the HPS strut. The results show that the variations in fluid compressibility and free gas volume cause increase in effective stiffness but considerable reduction in the damping in a highly nonlinear manner. Increasing the gas volume fraction resulted in substantial hysteresis in the force-deflection and force-velocity characteristics of the strut.
40 CFR 1066.140 - Diluted exhaust flow calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... whenever corrective action does not resolve a failure to meet the diluted exhaust flow verification (i.e... subsonic venturi flow meter, a long-radius ASME/NIST flow nozzle, a smooth approach orifice, a laminar flow...
40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... initial CVS installation and whenever corrective action does not resolve a failure to meet the diluted... such as a subsonic venturi flow meter, a long-radius ASME/NIST flow nozzle, a smooth approach orifice...
40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... initial CVS installation and whenever corrective action does not resolve a failure to meet the diluted... such as a subsonic venturi flow meter, a long-radius ASME/NIST flow nozzle, a smooth approach orifice...
40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... initial CVS installation and whenever corrective action does not resolve a failure to meet the diluted... such as a subsonic venturi flow meter, a long-radius ASME/NIST flow nozzle, a smooth approach orifice...
Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.
Kozłowski, Dariusz; Hreczecha, Jolanta; Skwarek, Magdalena; Piwko, Grzegorz; Kosiński, Adam; Gawrysiak, Marcin; Grzybiak, Marek
2003-05-01
Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.02 mm (diameter 1), 8.97 mm (diameter 2), 17.27 mm (diameter 3), 26.87 mm (diameter 4), 36.42 mm (diameter 5). In the mature adult hearts all the diameters measured ranged from 8 to 45 mm; 18.19 mm (diameter 1), 10.54 mm (diameter 2), 19.95 mm (diameter 3), 28.90 mm (diameter 4), 39.63 mm (diameter 5). In the older adults hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.65 mm (diameter 1), 8.70 mm (diameter 2), 7.25 mm (diameter 3), 26.80 mm (diameter 4), 35.85 mm (diameter 5). On the basis of our study we were able to conclude that the diameters of the cavo-sinus-tricuspid area were constant and did not differ significantly within the three (young, mature, old) adult groups examined.
Gas Atmospheres Improve Silicon-Ribbon Quality
NASA Technical Reports Server (NTRS)
Wald, F. V.; Kalejs, J. P.
1985-01-01
Growing crystal surrounded by gas containing carbon or oxygen. Ribbon of solid silicon, edgewise, grows from pool of molten silicon in die. Gases flowing through orifice ensure longer diffusion length and less contaminiation by carbide particles in product.
43 CFR 3275.16 - What standards apply to installing and maintaining meters?
Code of Federal Regulations, 2012 CFR
2012-10-01
...; (2) You must calibrate meters measuring steam or hot water flow with a turbine, vortex, ultrasonics... frequent; and (3) You must calibrate meters measuring steam or hot water flow with an orifice plate...
43 CFR 3275.16 - What standards apply to installing and maintaining meters?
Code of Federal Regulations, 2011 CFR
2011-10-01
...; (2) You must calibrate meters measuring steam or hot water flow with a turbine, vortex, ultrasonics... frequent; and (3) You must calibrate meters measuring steam or hot water flow with an orifice plate...
43 CFR 3275.16 - What standards apply to installing and maintaining meters?
Code of Federal Regulations, 2014 CFR
2014-10-01
...; (2) You must calibrate meters measuring steam or hot water flow with a turbine, vortex, ultrasonics... frequent; and (3) You must calibrate meters measuring steam or hot water flow with an orifice plate...
43 CFR 3275.16 - What standards apply to installing and maintaining meters?
Code of Federal Regulations, 2013 CFR
2013-10-01
...; (2) You must calibrate meters measuring steam or hot water flow with a turbine, vortex, ultrasonics... frequent; and (3) You must calibrate meters measuring steam or hot water flow with an orifice plate...
40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... action does not resolve a failure to meet the diluted exhaust flow verification (i.e., propane check) in... subsonic venturi flow meter, a long-radius ASME/NIST flow nozzle, a smooth approach orifice, a laminar flow...
Bokhari, Awais; Yusup, Suzana; Chuah, Lai Fatt; Klemeš, Jiří Jaromír; Asif, Saira; Ali, Basit; Akbar, Majid Majeed; Kamil, Ruzaimah Nik M
2017-10-01
Chemical interesterification of rubber seed oil has been investigated for four different designed orifice devices in a pilot scale hydrodynamic cavitation (HC) system. Upstream pressure within 1-3.5bar induced cavities to intensify the process. An optimal orifice plate geometry was considered as plate with 1mm dia hole having 21 holes at 3bar inlet pressure. The optimisation results of interesterification were revealed by response surface methodology; methyl acetate to oil molar ratio of 14:1, catalyst amount of 0.75wt.% and reaction time of 20min at 50°C. HC is compared to mechanical stirring (MS) at optimised values. The reaction rate constant and the frequency factor of HC were 3.4-fold shorter and 3.2-fold higher than MS. The interesterified product was characterised by following EN 14214 and ASTM D 6751 international standards. Copyright © 2017 Elsevier Ltd. All rights reserved.
Testing and Analysis of NEXT Ion Engine Discharge Cathode Assembly Wear
NASA Technical Reports Server (NTRS)
Domonkos, Matthew T.; Foster, John E.; Soulas, George C.; Nakles, Michael
2003-01-01
Experimental and analytical investigations were conducted to predict the wear of the discharge cathode keeper in the NASA Evolutionary Xenon Thruster. The ion current to the keeper was found to be highly dependent upon the beam current, and the average beam current density was nearly identical to that of the NSTAR thruster for comparable beam current density. The ion current distribution was highly peaked toward the keeper orifice. A deterministic wear assessment predicted keeper orifice erosion to the same diameter as the cathode tube after processing 375 kg of xenon. A rough estimate of discharge cathode assembly life limit due to sputtering indicated that the current design exceeds the qualification goal of 405 kg. Probabilistic wear analysis showed that the plasma potential and the sputter yield contributed most to the uncertainty in the wear assessment. It was recommended that fundamental experimental and modeling efforts focus on accurately describing the plasma potential and the sputtering yield.
Fuel-air mixing apparatus for reducing gas turbine combustor exhaust emissions
NASA Technical Reports Server (NTRS)
Zupanc, Frank J. (Inventor); Yankowich, Paul R. (Inventor)
2006-01-01
A fuel-air mixer for use in a combustion chamber of a gas turbine engine is provided. The fuel air mixing apparatus comprises an annular fuel injector having a plurality of discrete plain jet orifices, a first swirler wherein the first swirler is located upstream from the fuel injector and a second swirler wherein the second swirler is located downstream from the fuel injector. The plurality of discrete plain jet orifices are situated between the highly swirling airstreams generated by the two radial swirlers. The distributed injection of the fuel between two highly swirling airstreams results in rapid and effective mixing to the desired fuel-air ratio and prevents the formation of local hot spots in the combustor primary zone. A combustor and a gas turbine engine comprising the fuel-air mixer of the present invention are also provided as well as a method using the fuel-air mixer of the present invention.
Turbine airfoil with laterally extending snubber having internal cooling system
Scribner, Carmen Andrew; Messmann, Stephen John; Marsh, Jan H.
2016-09-06
A turbine airfoil usable in a turbine engine and having at least one snubber with a snubber cooling system positioned therein and in communication with an airfoil cooling system is disclosed. The snubber may extend from the outer housing of the airfoil toward an adjacent turbine airfoil positioned within a row of airfoils. The snubber cooling system may include an inner cooling channel separated from an outer cooling channel by an inner wall. The inner wall may include a plurality of impingement cooling orifices that direct impingement fluid against an outer wall defining the outer cooling channel. In one embodiment, the cooling fluids may be exhausted from the snubber, and in another embodiment, the cooling fluids may be returned to the airfoil cooling system. Flow guides may be positioned in the outer cooling channel, which may reduce cross-flow by the impingement orifices, thereby increasing effectiveness.
One-Piece Battery Incorporating A Circulating Fluid Type Heat Exchanger
Verhoog, Roelof
2001-10-02
A one-piece battery comprises a tank divided into cells each receiving an electrode assembly, closure means for the tank and a circulating fluid type heat exchanger facing the relatively larger faces of the electrode assembly. The fluid flows in a compartment defined by two flanges which incorporate a fluid inlet orifice communicating with a common inlet manifold and a fluid outlet orifice communicating with a common outlet manifold. The tank comprises at least two units and each unit comprises at least one cell delimited by walls. The wall facing a relatively larger face of the electrode assembly constitutes one of the flanges. Each unit further incorporates a portion of an inlet and outlet manifold. The units are fastened together so that the flanges when placed face-to-face form a sealed circulation compartment and the portions of the same manifold are aligned with each other.
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor); Buskirk, Paul D. (Inventor)
2006-01-01
An orifice plate for use in a conduit through which fluid flows is defined by a central circular region having a radius R, and a ring-shaped region surrounding the central circular region. The ring-shaped region has holes formed therethrough with those holes centered at each radius R thereof satisfying a relationship A(sub R)=al(X(sub R)V(sub R)(sup b)) where A(sub R) is a sum of areas of those holes having centers at radius R, X(sub R) is a flow coefficient at radius R, V(sub R) is a velocity of the fluid that is to flow through the conduit at radius R, b is a constant selected to make at least one process variable (associated with the fluid that is to flow through the conduit) approximately equal at each radius R, and a is a constant that is equal to (X(sub R)A(sub R)V(sub R)(sup b)) at each radius R.
Treatment of Traumatic Esophagopleural Fistula Using the Over-the-Scope-Clip System.
Kim, Ji Hyoung; Park, Jong-Jae; Jung, Il Woo; Kim, Sang Hoon; Kim, Hee Dong; Choe, Jung Wan; Joo, Moon Kyung; Kim, Hyun Gu
2015-09-01
Esophagopleural fistula (EPF) is a rare condition that is usually accompanied by severe infection and life-threatening morbidity. Here, we report the successful treatment of an EPF by closing an esophageal orifice using the over-the-scope-clip (OTSC) system without postprocedural complications. A 41-year-old man had serious thoracic and abdominal trauma due to a traffic accident. Computed tomography revealed findings suggestive of esophageal rupture due to Boerhaave syndrome. An emergent explorative operation was performed for primary repair with the insertion of a vacuum-assisted closure device. A postoperative upper gastrointestinal series revealed an EPF tract connecting the left pleural space and distal esophagus. We performed an endoscopic procedure using the "traumatic-type"OTSC to seal the EPF, and the esophageal orifice was completely healed 2 weeks postoperatively. The OTSC system might represent a safe and feasible modality for the treatment of EPF.
NASA Technical Reports Server (NTRS)
Foster, Lancert; Engblom, William A.
2003-01-01
Computational results are presented for the performance and flow behavior of various injector geometries employed in transverse injection into a non-reacting Mach 1.2 flow. 3-D Reynolds-Averaged Navier Stokes (RANS) results are obtained for the various injector geometries using the Wind code with the Mentor s Shear Stress Transport turbulence model in both single and multi-species modes. Computed results for the injector mixing, penetration, and induced wall forces are presented. In the case of rectangular injectors, those longer in the direction of the freestream flow are predicted to generate the most mixing and penetration of the injector flow into the primary stream. These injectors are also predicted to provide the largest discharge coefficients and induced wall forces. Minor performance differences are indicated among diamond, circle, and square orifices. Grid sensitivity study results are presented which indicate consistent qualitative trends in the injector performance comparisons with increasing grid fineness.
Note: High temperature pulsed solenoid valve.
Shen, Wei; Sulkes, Mark
2010-01-01
We have developed a high temperature pulsed solenoid valve with reliable long term operation to at least 400 degrees C. As in earlier published designs, a needle extension sealing a heated orifice is lifted via solenoid actuation; the solenoid is thermally isolated from the heated orifice region. In this new implementation, superior sealing and reliability were attained by choosing a solenoid that produces considerably larger lifting forces on the magnetically actuated plunger. It is this property that facilitates easily attainable sealing and reliability, albeit with some tradeoff in attainable gas pulse durations. The cost of the solenoid valve employed is quite low and the necessary machining quite simple. Our ultimate level of sealing was attained by making a simple modification to the polished seal at the needle tip. The same sealing tip modification could easily be applied to one of the earlier high T valve designs, which could improve the attainability and tightness of sealing for these implementations.
Fox, P R; Miller, M W; Liu, S K
1992-11-15
Mitral stenosis was diagnosed noninvasively by echocardiography and Doppler imaging in 2 Bull Terriers. Two-dimensional echocardiography revealed severe atrial and moderate left ventricular dilatation; severely reduced mitral valve opening excursion; doming of the cranial mitral valve leaflet into the left ventricle during diastole; thickened, nodular cranial mitral valve leaflets; and reduced mitral valve orifice. M-mode echocardiographic findings additionally indicated greatly diminished mitral valve E to F slope and abnormal caudal mitral valve leaflet motion. Color flow Doppler imaging revealed bright bursts of color with aliasing originating from the stenotic mitral valve orifice, extending into the left atrium during systole, and into the left atrium during diastole. Spectral Doppler recordings revealed transvalvular mitral valve gradients and prolonged pressure half-times. Necropsy performed on 1 dog revealed extremely thickened, nodular, and stiff mitral valves with short, thickened, and fused chordae tendineae. The diagnosis of mitral valve stenosis was easily facilitated with diagnostic ultrasonography.
2009-01-01
Background A 23-year-old female patient presented to the outpatient clinic with bilateral nasal obstruction and discharge since birth. Endoscopic examination and paranasal sinus tomography revealed bilateral choanal atresia. She did not have any other congenital abnormalities. Her parents reported cyanosis in childhood that worsened during feeding and improved during crying; however, they had not visited a physician. She did not have remarkable complaints during early childhood or adolescence. Methods The patient was operated under general anesthesia, using a 0° 4 mm rigid endoscope. The orifice was widened with a curette and, to prevent stenosis, mitomycin-C (1 mg/ml) was applied topically to the nasopharyngeal orifice for 5 minutes. No stents were placed. Results Follow-up evaluation at postoperative 12th month showed that her symptoms improved significantly and, on endoscopic examination, both choanae remained patent. PMID:20062630
Curved film cooling admission tube
NASA Astrophysics Data System (ADS)
Graham, R. W.; Papell, S. S.
1980-10-01
Effective film cooling to protect a wall surface from a hot fluid which impinges on or flows along the surface is provided. A film of cooling fluid having increased area is provided by changing the direction of a stream of cooling fluid through an angle of from 135 deg. to 165 deg. before injecting it through the wall into the hot flowing gas. The 1, cooling fluid is injected from an orifice through a wall into a hot flowing gas at an angle to form a cooling fluid film. Cooling fluid is supplied to the orifice from a cooling fluid source via a turbulence control passageway having a curved portion between two straight portions. The angle through which the direction of the cooling fluid is turned results in less mixing of the cooling fluid with the hot gas, thereby substantially increasing the length of the film in a downstream direction.
Curved film cooling admission tube
NASA Technical Reports Server (NTRS)
Graham, R. W.; Papell, S. S. (Inventor)
1980-01-01
Effective film cooling to protect a wall surface from a hot fluid which impinges on or flows along the surface is provided. A film of cooling fluid having increased area is provided by changing the direction of a stream of cooling fluid through an angle of from 135 deg. to 165 deg. before injecting it through the wall into the hot flowing gas. The 1, cooling fluid is injected from an orifice through a wall into a hot flowing gas at an angle to form a cooling fluid film. Cooling fluid is supplied to the orifice from a cooling fluid source via a turbulence control passageway having a curved portion between two straight portions. The angle through which the direction of the cooling fluid is turned results in less mixing of the cooling fluid with the hot gas, thereby substantially increasing the length of the film in a downstream direction.
Method and apparatus for calibrating a linear variable differential transformer
Pokrywka, Robert J [North Huntingdon, PA
2005-01-18
A calibration apparatus for calibrating a linear variable differential transformer (LVDT) having an armature positioned in au LVDT armature orifice, and the armature able to move along an axis of movement. The calibration apparatus includes a heating mechanism with an internal chamber, a temperature measuring mechanism for measuring the temperature of the LVDT, a fixture mechanism with an internal chamber for at least partially accepting the LVDT and for securing the LVDT within the heating mechanism internal chamber, a moving mechanism for moving the armature, a position measurement mechanism for measuring the position of the armature, and an output voltage measurement mechanism. A method for calibrating an LVDT, including the steps of: powering the LVDT; heating the LVDT to a desired temperature; measuring the position of the armature with respect to the armature orifice; and measuring the output voltage of the LVDT.
NASA Astrophysics Data System (ADS)
McDowell, R. E.; Giammarise, A. W.; Johnson, R. N.
1994-01-01
Over 200 operating cylinder hours were run on critical wearing engine parts. The main components tested included cylinder liners, piston rings, and fuel injector nozzles for coal/water slurry fueled operation. The liners had no visible indication of scoring nor major wear steps found on their tungsten carbide coating. While the tungsten carbide coating on the rings showed good wear resistance, some visual evidence suggests adhesive wear mode was present. Tungsten carbide coated rings running against tungsten carbide coated liners in GE 7FDL engines exhibit wear rates which suggest an approximate 500 to 750 hour life. Injector nozzle orifice materials evaluated were diamond compacts, chemical vapor deposited diamond tubes, and thermally stabilized diamond. Based upon a total of 500 cylinder hours of engine operation (including single-cylinder combustion tests), diamond compact was determined to be the preferred orifice material.
Atmospheric cloud physics laboratory project study
NASA Technical Reports Server (NTRS)
Schultz, W. E.; Stephen, L. A.; Usher, L. H.
1976-01-01
Engineering studies were performed for the Zero-G Cloud Physics Experiment liquid cooling and air pressure control systems. A total of four concepts for the liquid cooling system was evaluated, two of which were found to closely approach the systems requirements. Thermal insulation requirements, system hardware, and control sensor locations were established. The reservoir sizes and initial temperatures were defined as well as system power requirements. In the study of the pressure control system, fluid analyses by the Atmospheric Cloud Physics Laboratory were performed to determine flow characteristics of various orifice sizes, vacuum pump adequacy, and control systems performance. System parameters predicted in these analyses as a function of time include the following for various orifice sizes: (1) chamber and vacuum pump mass flow rates, (2) the number of valve openings or closures, (3) the maximum cloud chamber pressure deviation from the allowable, and (4) cloud chamber and accumulator pressure.
Wahengbam, Brucelee; Wahengbam, Pragya; Tikku, Aseem Prakash
2014-01-01
This article suggests a simplified technique of orthograde MTA obturation in less accessible canal(s) of posteriors teeth without using costly ultrasonics or specialised carrier. Essentially few finger pluggers, absorbent points and a simple canal projection method were used. The orifice(s) of the elected canal(s) to be obturated with MTA were projected onto the external occlusal surface for easy delivery and predictive instrumentation. The idea was based on 'easy access', 'working one canal with one mix at one time', 'thorough condensation' and 'removal of excess moisture'. In case I, palatal canal of tooth no. 2 with gross apical perforation and suspected VRF was obturated with MTA. And in Case II, tooth no. 19 presented with incomplete furcal fracture extending into the canal was obturated with MTA in all 3 canals unitarily. Dense homogenous MTA obturation was achieved and both cases healed uneventfully.
An organic self-regulating microfluidic system.
Eddington, D T; Liu, R H; Moore, J S; Beebe, D J
2001-12-01
In this paper we present an organic feedback scheme that merges microfluidics and responsive materials to address several limitations of current microfluidic systems. By using in situ fabrication and by taking advantage of microscale phenomena (e.g., laminar flow, short diffusion times), we have demonstrated feedback control of the output pH in a completely organic system. The system autonomously regulates an output stream at pH 7 under a range of input flow conditions. A single responsive hydrogel component performs the functionality of traditional feedback system components. Vertically stacked laminar flow is used to improve the time response of the hydrogel actuator. A star shaped orifice is utilized to improve the flow characteristics of the membrane/orifice valve. By changing the chemistry of the hydrogel component, the system can be altered to regulate flow based on hydrogels sensitive to temperature, light, biological/molecular, and others.
Gimeno, Marina; Pinczowski, Pedro; Pérez, Marta; Giorello, Antonella; Martínez, Miguel Ángel; Santamaría, Jesús; Arruebo, Manuel; Luján, Lluís
2015-01-01
A new device for local delivery of antibiotics is presented, with potential use as a drug-eluting fixation pin for orthopedic applications. The implant consists of a stainless steel hollow tubular reservoir packed with the desired antibiotic. Release takes place through several orifices previously drilled in the reservoir wall, a process that does not compromise the mechanical properties required for the implant. Depending on the antibiotic chosen and the number of orifices, the release profile can be tailored from a rapid release of the load (ca. 20 h) to a combination of rapid initial release and slower, sustained release for a longer period of time (ca. 200 h). An excellent bactericidal action is obtained, with 4-log reductions achieved in as little as 2 h, and total bacterial eradication in 8 h using 6-pinholed implants filled with cefazolin. PMID:26297104
Son, Jaebum; Cho, Chang Nho; Kim, Kwang Gi; Chang, Tae Young; Jung, Hyunchul; Kim, Sung Chun; Kim, Min-Tae; Yang, Nari; Kim, Tae-Yun; Sohn, Dae Kyung
2015-06-01
Natural orifice transluminal endoscopic surgery (NOTES) is an emerging surgical technique. We aimed to design, create, and evaluate a new semi-automatic snake robot for NOTES. The snake robot employs the characteristics of both a manual endoscope and a multi-segment snake robot. This robot is inserted and retracted manually, like a classical endoscope, while its shape is controlled using embedded robot technology. The feasibility of a prototype robot for NOTES was evaluated in animals and human cadavers. The transverse stiffness and maneuverability of the snake robot appeared satisfactory. It could be advanced through the anus as far as the peritoneal cavity without any injury to adjacent organs. Preclinical tests showed that the device could navigate the peritoneal cavity. The snake robot has advantages of high transverse force and intuitive control. This new robot may be clinically superior to conventional tools for transanal NOTES.
Characterization of typical platelet injector flow configurations. [liquid propellant rocket engines
NASA Technical Reports Server (NTRS)
Hickox, C. E.
1975-01-01
A study to investigate the hydraulic atomization characteristics of several novel injector designs for use in liquid propellant rocket engines is presented. The injectors were manufactured from a series of thin stainless steel platelets through which orifices were very accurately formed by a photoetching process. These individual platelets were stacked together and the orifices aligned so as to produce flow passages of prescribed geometry. After alignment, the platelets were bonded into a single, 'platelet injector', unit by a diffusion bonding process. Because of the complex nature of the flow associated with platelet injectors, it was necessary to use experimental techniques, exclusively, throughout the study. Large scale models of the injectors were constructed from aluminum plates and the appropriate fluids were modeled using a glycerol-water solution. Stop-action photographs of test configurations, using spark-shadowgraph or stroboscopic back-lighting, are shown.
Sealed Battery Block Provided With A Cooling System
Verhoog, Roelof; Barbotin, Jean-Loup
1999-11-16
The present invention relates to a sealed battery block operating at a pressure of at least 1 bar relative, the battery including a container made of a plastics material and made up of a lid and of a case subdivided into wells by at least one partition, said battery being provided with a cooling system including two cheek plates made of a plastics material and co-operating with the outside faces of respective ones of two opposite walls of said case, each cheek plate co-operating with the corresponding wall to define a compartment provided with a plurality of ribs forming baffles for fluid flow purposes, and with an inlet orifice and an outlet orifice for the fluid, said battery being characterized in that each of said ribs extends in a direction that forms an angle relative to the plane of said partition lying in the range 60.degree. to 90.degree..
Concentric micro-nebulizer for direct sample insertion
Fassel, V.A.; Rice, G.W.; Lawrence, K.E.
1984-03-06
A concentric micro-nebulizer and method for introducing liquid samples into a plasma established in a plasma torch including a first tube connected to a source of plasma gas. The concentric micro-nebulizer has inner and outer concentric tubes extending upwardly within the torch for connection to a source of nebulizer gas and to a source of liquid solvent and to a source of sample liquid. The inner tube is connected to the source of liquid solvent and to the source of sample liquid and the outer tube is connected to the source of nebulizer gas. The outer tube has an orifice positioned slightly below the plasma when it is established, with the inner and outer tubes forming an annulus therebetween with the annular spacing between the tubes at said orifice being less than about 0.05mm. The dead volume of the inner tube is less than about 5 microliters.
Concentric micro-nebulizer for direct sample insertion
Fassel, Velmer A.; Rice, Gary W.; Lawrence, Kimberly E.
1986-03-11
A concentric micro-nebulizer and method for introducing liquid samples into a plasma established in a plasma torch including a first tube connected to a source of plasma gas. The concentric micro-nebulizer has inner and outer concentric tubes extending upwardly within the torch for connection to a source of nebulizer gas and to a source of liquid solvent and to a source of sample liquid. The inner tube is connected to the source of liquid solvent and to the source of sample liquid and the outer tube is connected to the source of nebulizer gas. The outer tube has an orifice positioned slightly below the plasma when it is established, with the inner and outer tubes forming an annulus therebetween with the annular spacing between the tubes at said orifice being less than about 0.05 mm. The dead volume of the inner tube is less than about 5 microliters.
Regional blood flow volume in the eustachian tube.
Minami, T; Kubo, N; Tomoda, K; Yamashita, T; Kumazawa, T
1993-01-01
Measurements of regional blood flow around the pharyngeal orifice of the Eustachian tube were carried out after topical administration of various inflammatory mediators in 14 mongrel dogs by the hydrogen clearance method. Histamine and platelet-activating factor (PAF) resulted in a significant alteration of blood flow volume. Histamine was found to induce a dose-response related increase, whereas blood flow volume tended to decrease in each concentration range in the series of PAF administration. There was no significant difference in blood flow between topical application of leukotriene C4 and leukotriene D4. It is likely that in upper respiratory tract inflammation, such as in otitis media and in nasal allergy, activated histamine and PAF affect the microcirculation of the tubal orifice. These results suggest that disturbance of the microcirculatory system in the Eustachian tube mucosa could be involved in the pathogenesis of chronic otitis media with effusion.
House, Chad M; Nelson, William B; Kroshus, Timothy J; Dahiya, Ranjan; Pibarot, Philippe
2012-01-01
Prosthesis-patient mismatch (PPM) occurs when an implanted prosthesis is too small relative to the patient's body surface area (BSA). However, mismatch can often be prevented by indexing the expected effective orifice area (EOA) of a prosthesis to the patient's BSA and then selecting the largest implantable prosthesis to avoid mismatch. Previously, prosthesis manufacturers have attempted to simplify this process by providing charts that include the expected EOA for their prosthesis, already indexed into an array of BSA values. One caveat with these charts is that the expected EOA data must truly be reliable, or the charts will misguide the implanting surgeon. Manufacturer-provided charts could be improved by standardizing the EOA data, with one potential source being the hemodynamic data submitted to the United States Food and Drug Administration. This review discusses PPM, manufacturer-provided EOA charts, and the regulation of EOA data.
Vapor-barrier Vacuum Isolation System
NASA Technical Reports Server (NTRS)
Weinstein, Leonard M. (Inventor); Taminger, Karen M. (Inventor)
2014-01-01
A system includes a collimated beam source within a vacuum chamber, a condensable barrier gas, cooling material, a pump, and isolation chambers cooled by the cooling material to condense the barrier gas. Pressure levels of each isolation chamber are substantially greater than in the vacuum chamber. Coaxially-aligned orifices connect a working chamber, the isolation chambers, and the vacuum chamber. The pump evacuates uncondensed barrier gas. The barrier gas blocks entry of atmospheric vapor from the working chamber into the isolation chambers, and undergoes supersonic flow expansion upon entering each isolation chamber. A method includes connecting the isolation chambers to the vacuum chamber, directing vapor to a boundary with the working chamber, and supersonically expanding the vapor as it enters the isolation chambers via the orifices. The vapor condenses in each isolation chamber using the cooling material, and uncondensed vapor is pumped out of the isolation chambers via the pump.
Levitte, D.; Eckstein, Y.
1978-01-01
Analysis of twenty-one thermal springs emerging along the Jordan-Dead Sea Rift Valley in Israel indicates a very good correlation between the concentration of dissolved silica and the temperature of the spring orifice. Dissolution of quartz was identified as the apparent source of the silica in the water. Application of the silica geothermometer for mixed systems suggests that the springs in the Tiberias Lake Basin are supplied with hot water from deep reservoir (or reservoirs) at a temperature of 115??C (239??F). The same temperature was postulated earlier by the application of the Na-K-Ca hydro-geothermometer to a group of thermal springs in the same basin. The temperature of the reservoir supplying hot brines to the springs emerging along the western shore of the Dead Sea is estimated at 90??C (194??F).
Apparatus and method for polymer synthesis using arrays
Brennan, Thomas M.
1995-01-01
A polymer synthesis apparatus (20) for building a polymer chain including a head assembly (21) having an array of nozzles (22) with each nozzle coupled to a reservoir (23) of liquid reagent (24) , and a base assembly (25) having an array of reaction wells (26). A transport mechanism (27) aligns the reaction wells (26) and selected nozzles (22) for deposition of the liquid reagent (24) into selected reaction wells (26). A sliding seal (30) is positioned between the head assembly (21) and the base assembly (25) to form a common chamber (31) enclosing both the reaction well (26) and the nozzles (22) therein. A gas inlet (70) into the common chamber (31), upstream from the nozzles (22), and a gas outlet (71) out of the common chamber (31) , downstream from the nozzles (22) , sweeps the common chamber ( 31 ) of toxic fumes emitted by the reagents. Each reaction well (26) includes an orifice (74) extending into the well (26) which is of a size and dimension to form a capillary liquid seal to retain the reagent solution (76) in the well (26) for polymer chain growth therein. A pressure regulating device (82) is provided for controlling a pressure differential, between a first gas pressure exerted on the reaction well (26) and a second gas pressure exerted on an exit (80) of the orifice, such that upon the pressure differential exceeding a predetermined amount, the reagent solution (76) is expelled from the well (26) through the orifice (74). A method of synthesis of a polymer chain in a synthesis apparatus (20) is also included.
Apparatus and method for polymer synthesis using arrays
Brennan, Thomas M.
1996-01-01
A polymer synthesis apparatus (20) for building a polymer chain including a head assembly (21) having an array of nozzles (22) with each nozzle coupled to a reservoir (23) of liquid reagent (24), and a base assembly (25) having an array of reaction wells (26). A transport mechanism (27) aligns the reaction wells (26) and selected nozzles (22) for deposition of the liquid reagent (24) into selected reaction wells (26). A sliding seal (30) is positioned between the head assembly (21) and the base assembly (25) to form a common chamber (31) enclosing both the reaction well (26) and the nozzles (22) therein. A gas inlet (70) into the common chamber (31), upstream from the nozzles (22), and a gas outlet (71) out of the common chamber (31), downstream from the nozzles (22), sweeps the common chamber (31) of toxic fumes emitted by the reagents. Each reaction well ( 26) includes an orifice (74) extending into the well (26) which is of a size and dimension to form a capillary liquid seal to retain the reagent solution (76) in the well (26) for polymer chain growth therein. A pressure regulating device (82 ) is provided for controlling a pressure differential, between a first gas pressure exerted on the reaction well (26) and a second gas pressure exerted on an exit (80) of the orifice, such that upon the pressure differential exceeding a predetermined amount, the reagent solution (76) is expelled from the well (26) through the orifice (74). A method of synthesis of a polymer chain in a synthesis apparatus (20) is also included.
The Measurement of Pressure Through Tubes in Pressure Distribution Tests
NASA Technical Reports Server (NTRS)
Hemke, Paul E
1928-01-01
The tests described in this report were made to determine the error caused by using small tubes to connect orifices on the surface of aircraft to central pressure capsules in making pressure distribution tests. Aluminum tubes of 3/16-inch inside diameter were used to determine this error. Lengths from 20 feet to 226 feet and pressures whose maxima varied from 2 inches to 140 inches of water were used. Single-pressure impulses for which the time of rise of pressure from zero to a maximum varied from 0.25 second to 3 seconds were investigated. The results show that the pressure recorded at the capsule on the far end of the tube lags behind the pressure at the orifice end and experiences also a change in magnitude. For the values used in these tests the time lag and pressure change vary principally with the time of rise of pressure from zero to a maximum and the tube length. Curves are constructed showing the time lag and pressure change. Empirical formulas are also given for computing the time lag. Analysis of pressure distribution tests made on airplanes in flight shows that the recorded pressures are slightly higher than the pressures at the orifice and that the time lag is negligible. The apparent increase in pressure is usually within the experimental error, but in the case of the modern pursuit type of airplane the pressure increase may be 5 per cent. For pressure-distribution tests on airships the analysis shows that the time lag and pressure change may be neglected.
Murphy, I G; Collins, J; Powell, A; Markl, M; McCarthy, P; Malaisrie, S C; Carr, J C; Barker, A J
2017-08-01
Bicuspid aortic valve (BAV) disease is heterogeneous and related to valve dysfunction and aortopathy. Appropriate follow up and surveillance of patients with BAV may depend on correct phenotypic categorization. There are multiple classification schemes, however a need exists to comprehensively capture commissure fusion, leaflet asymmetry, and valve orifice orientation. Our aim was to develop a BAV classification scheme for use at MRI to ascertain the frequency of different phenotypes and the consistency of BAV classification. The BAV classification scheme builds on the Sievers surgical BAV classification, adding valve orifice orientation, partial leaflet fusion and leaflet asymmetry. A single observer successfully applied this classification to 386 of 398 Cardiac MRI studies. Repeatability of categorization was ascertained with intraobserver and interobserver kappa scores. Sensitivity and specificity of MRI findings was determined from operative reports, where available. Fusion of the right and left leaflets accounted for over half of all cases. Partial leaflet fusion was seen in 46% of patients. Good interobserver agreement was seen for orientation of the valve opening (κ = 0.90), type (κ = 0.72) and presence of partial fusion (κ = 0.83, p < 0.0001). Retrospective review of operative notes showed sensitivity and specificity for orientation (90, 93%) and for Sievers type (73, 87%). The proposed BAV classification schema was assessed by MRI for its reliability to classify valve morphology in addition to illustrating the wide heterogeneity of leaflet size, orifice orientation, and commissural fusion. The classification may be helpful in further understanding the relationship between valve morphology, flow derangement and aortopathy.
CFD mixing analysis of axially opposed rows of jets injected into confined crossflow
NASA Technical Reports Server (NTRS)
Bain, D. B.; Smith, C. E.; Holdeman, J. D.
1993-01-01
A computational fluid dynamics (CFD) parametric study was performed to analyze axially opposed rows of jets mixing with crossflow in a rectangular duct. Isothermal analysis was conducted to determine the influence of lateral geometric arrangement on mixing. Two lateral arrangements were analyzed: (1) inline (jets' centerlines aligned with each other on top and bottom walls), and (2) staggered (jets' centerlines offset with each other on top and bottom walls). For a jet-to-mainstream mass flow ratio (MR) of 2.0, design parameters were systematically varied for jet-to-mainstream momentum-flux ratios (J) between 16 and 64 and orifice spacing-to-duct height ratios (S/H) between 0.125 and 1.5. Comparisons were made between geometries optimized for S/H at a specified J. Inline configurations had a unique spacing for best mixing at a specified J. In contrast, staggered configurations had two 'good mixing' spacings for each J, one corresponding to optimum inline spacing and the other corresponding to optimum non-impinging jet spacing. The inline configurations, due to their smaller orifice size at optimum S/H, produced better initial mixing characteristics. At downstream locations (e.g. x/H of 1.5), the optimum non-impinging staggered configuration produced better mixing than the optimum inline configuration for J of 64; the opposite results were observed for J of 16. Increasing J resulted in better mixing characteristics if each configuration was optimized with respect to orifice spacing. Mixing performance was shown to be similar to results from previous dilution jet mixing investigations (MR less than 0.5).
Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard
2017-04-01
Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78±16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow. © 2017, Wiley Periodicals, Inc.
Evaluation of cystoscopic-guided laser ablation of intramural ectopic ureters in female dogs.
Berent, Allyson C; Weisse, Chick; Mayhew, Philipp D; Todd, Kimberly; Wright, Monika; Bagley, Demetrius
2012-03-15
To describe and evaluate the short- and long-term outcomes in female dogs after cystoscopic-guided laser ablation of ectopic ureters (CLA-EU). Prospective case series. 32 incontinent female dogs with intramural ectopic ureters. A diagnosis of intramural ectopic ureters was made via cystoscopy and fluoroscopy in all patients. Transurethral CLA-EU (via diode laser [n = 27] or Holmium:yttrium aluminum garnet laser [3]) was performed to relocate the ectopic ureteral orifice cranially into the urinary bladder. All vaginal anomalies were treated with the laser concurrently. Follow-up evaluation was standardized and included urinary continence scoring, serial bacteriologic culture of urine samples, and a follow-up cystoscopy 6 to 8 weeks after CLA-EU. Ectopic ureteral orifices of all dogs were initially located in the urethra. Eighteen of 30 dogs had bilateral ectopic ureters, and 12 had unilateral ectopic ureters. All dogs had other concurrent urinary anomalies. At the time of last follow-up (median, 2.7 years after CLA-EU, [range, 12 to 62 months]), 14 of 30 (47%) dogs did not require any additional treatments following CLA-EU to maintain urinary continence. For the 16 residually incontinent dogs, the addition of medical management, transurethral bulking-agent injection, or placement of a hydraulic occluder was effective in 3, 2, and 4 dogs, respectively, improving the overall urinary continence rate to 77% (23/30 dogs). One dog had evidence of polypoid cystitis at the neoureteral orifice 6 weeks after CLA-EU that was resolved at 3 months. CLA-EU provided an effective, safe, and minimally invasive alternative to surgery for intramural ectopic ureters in female dogs.
Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael
2017-07-01
Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.
Yoshizumi, F; Yasuda, K; Kawaguchi, K; Suzuki, K; Shiraishi, N; Kitano, S
2009-08-01
Safe peritoneal access and gastric closure are the most important concerns in the clinical application of natural orifice transluminal endoscopic surgery (NOTES). We aimed to clarify the feasibility of a submucosal tunnel technique using endoscopic submucosal dissection (ESD) for transgastric peritoneal access and subsequent closure for NOTES. Seven female pigs, each weighing about 40 kg were included in the study. The following procedures were performed: (i) after injection of normal saline into the submucosa, the mucosa was cut with a flex knife; (ii) the submucosal layer was dissected using an insulation-tipped electrosurgical knife to make a narrow longitudinal 50-mm submucosal tunnel; (iii) a small incision was made at the end of the tunnel and enlarged with a dilation balloon. After transgastric peritoneoscopy, the mucosal incision site was closed with clips. The following outcome measures were used: (a) evaluation of the technical feasibility of making a submucosal tunnel; (b) clinical monitoring for 7 days; (c) follow-up endoscopy and necropsy; and (d) peritoneal fluid culture. Natural orifice transluminal endoscopic peritoneoscopy with a submucosal tunnel was successfully carried out in all pigs. The pigs recovered well, without signs of peritonitis. Follow-up endoscopy showed healing of mucosal incision sites without open defects. Necropsy revealed no findings of peritonitis, confirming completeness of gastric closure; there was a thin scar in one pig and adhesion of the omentum in six pigs. Peritoneal fluid culture demonstrated no bacterial growth. The submucosal tunnel technique is feasible and effective for transgastric peritoneal access and closure.
Meibomian Gland Dysfunction Model in Hairless Mice Fed a Special Diet With Limited Lipid Content.
Miyake, Hideki; Oda, Tomoko; Katsuta, Osamu; Seno, Masaharu; Nakamura, Masatsugu
2016-06-01
A novel meibomian gland dysfunction (MGD) model was developed to facilitate understanding of the pathophysiology of MGD and to evaluate treatment with azithromycin ophthalmic solution (azithromycin). MGD was induced in HR-1 hairless mice by feeding them a special diet with limited lipid content (HR-AD). Male HR-1 hairless mice were fed an HR-AD diet for 16 weeks. Development of MGD was assessed by histopathology at 4-week intervals. The lid margin was observed by slit-lamp examination. After cessation of the HR-AD diet, the mice were fed a normal diet to restore normal eye conditions. Expression of cytokeratin 6 was determined by immunostaining. We evaluated the effects of topically applied azithromycin on the plugged orifice in this model. After mice were fed the HR-AD diet, histopathology analysis showed hyperkeratinization of the ductal epithelium in the meibomian gland. Ductal hyperkeratinization resulted in the loss of acini, followed by atrophy of the gland. Slit-lamp examination revealed a markedly plugged orifice, telangiectasia, and a toothpaste-like meibum compared with that of a normal eyelid. Cessation of feeding with HR-AD ameliorated both the MGD signs and the expression of cytokeratin 6, restoring the tissue to a histologically normal state. Azithromycin treatment significantly decreased the number of plugged orifices and ameliorated atrophy, as revealed by histopathologic analysis. We developed a novel model that mimics human MGD signs in HR-1 hairless mice fed an HR-AD diet. Azithromycin treatment led to therapeutic improvement in this model. This MGD model could be useful for the evaluation of drug candidates for MGD.
Inclined Jet in Crossflow Interacting with a Vortex Generator
NASA Technical Reports Server (NTRS)
Zaman, K. B. M. Q.; Rigby, D .L.; Heidmann, J. D.
2011-01-01
An experiment is conducted on the effectiveness of a vortex generator in preventing liftoff of a jet in crossflow, with possible relevance to film-cooling applications. The jet issues into the boundary layer at an angle of 20 degreees to the freestream. The effect of a triangular ramp-shaped vortex generator is studied while varying its geometry and location. Detailed flowfield properties are obtained for a case in which the height of the vortex generator and the diameter of the orifice are comparable with the approach boundary-layer thickness. The vortex generator produces a streamwise vortex pair with a vorticity magnitude 3 times larger (and of opposite sense) than that found in the jet in crossflow alone. Such a vortex generator appears to be most effective in keeping the jet attached to the wall. The effect of parametric variation is studied mostly from surveys 10 diameters downstream from the orifice. Results over a range of jet-to-freestream momentum flux ratio (1 < J < 11) show that the vortex generator has a significant effect even at the highest J covered in the experiment. When the vortex generator height is halved, there is a liftoff of the jet. On the other hand, when the height is doubled, the jet core is dissipated due to larger turbulence intensity. Varying the location of the vortex generator, over a distance of three diameters from the orifice, is found to have little impact. Rounding off the edges of the vortex generator with the increasing radius of curvature progressively diminishes its effect. However, allowing for a small radius of curvature may be quite tolerable in practice.
Electrosonic ejector microarray for drug and gene delivery.
Zarnitsyn, Vladimir G; Meacham, J Mark; Varady, Mark J; Hao, Chunhai; Degertekin, F Levent; Fedorov, Andrei G
2008-04-01
We report on development and experimental characterization of a novel cell manipulation device-the electrosonic ejector microarray-which establishes a pathway for drug and/or gene delivery with control of biophysical action on the length scale of an individual cell. The device comprises a piezoelectric transducer for ultrasound wave generation, a reservoir for storing the sample mixture and a set of acoustic horn structures that form a nozzle array for focused application of mechanical energy. The nozzles are micromachined in silicon or plastic using simple and economical batch fabrication processes. When the device is driven at a particular resonant frequency of the acoustic horn structures, the sample mixture of cells and desired transfection agents/molecules suspended in culture medium is ejected from orifices located at the nozzle tips. During sample ejection, focused mechanical forces (pressure and shear) are generated on a microsecond time scale (dictated by nozzle size/geometry and ejection velocity) resulting in identical "active" microenvironments for each ejected cell. This process enables a number of cellular bioeffects, from uptake of small molecules and gene delivery/transfection to cell lysis. Specifically, we demonstrate successful calcein uptake and transfection of DNA plasmid encoding green fluorescent protein (GFP) into human malignant glioma cells (cell line LN443) using electrosonic microarrays with 36, 45 and 50 mum diameter nozzle orifices and operating at ultrasound frequencies between 0.91 and 0.98 MHz. Our results suggest that efficacy and the extent of bioeffects are mainly controlled by nozzle orifice size and the localized intensity of the applied acoustic field.
30 CFR 7.97 - Application requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sensors, flame arresters, exhaust conditioner, emergency intake air shutoff device, automatic fuel shutoff...-cooled components, coolant lines, radiator, surge tank, temperature sensors, and orifices; arrows... internal parts, exhaust inlet and outlet, sensors, and the exhaust gas path through the exhaust conditioner...
30 CFR 7.97 - Application requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sensors, flame arresters, exhaust conditioner, emergency intake air shutoff device, automatic fuel shutoff...-cooled components, coolant lines, radiator, surge tank, temperature sensors, and orifices; arrows... internal parts, exhaust inlet and outlet, sensors, and the exhaust gas path through the exhaust conditioner...
30 CFR 7.97 - Application requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sensors, flame arresters, exhaust conditioner, emergency intake air shutoff device, automatic fuel shutoff...-cooled components, coolant lines, radiator, surge tank, temperature sensors, and orifices; arrows... internal parts, exhaust inlet and outlet, sensors, and the exhaust gas path through the exhaust conditioner...
Evaluation of rotating, incompressibly lubricated, pressurized thrust bearings
NASA Technical Reports Server (NTRS)
Fleming, D. P.
1971-01-01
Program evaluates a series hybrid, fluid film ball bearing consisting of an orifice compensated pressurized thrust bearing in conjunction with a self-acting journal bearing. Oil viscosities corresponding to experimentally measured ball bearing outer-race temperatures were used.
Code of Federal Regulations, 2013 CFR
2013-07-01
... chosen, you must report: (i) Annual emissions aggregated for all GHG from all applicable source... element (e.g., the orifice plate), or when there is only a differential pressure transmitter in close...
Code of Federal Regulations, 2011 CFR
2011-07-01
... the latter reporting option is chosen, you must report: (i) Annual emissions aggregated for all GHG... primary element (e.g., the orifice plate), or when there is only a differential pressure transmitter in...
Soldering tool heats workpieces and applies solder in one operation
NASA Technical Reports Server (NTRS)
Gudkese, V. W.
1966-01-01
Fountain-pen type soldering iron heats workpieces and applies solder to joints in densely packed electronics assemblies. The basic soldering tool is used with different-sized orifice tips, eliminating the need for an assortment of conventional soldering guns.
Pressure variable orifice for hydraulic control valve
NASA Technical Reports Server (NTRS)
Ammerman, R. L.
1968-01-01
Hydraulic valve absorbs impact energy generated in docking or joining of two large bodies by controlling energy release to avoid jarring shock. The area of exit porting presented to the hydraulic control fluid is directly proportional to the pressure acting on the fluid.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (c)(12)(iii) of this section. If the latter reporting option is chosen, you must report: (i) Annual... flow meter's primary element (e.g., the orifice plate), or when there is only a differential pressure...
von Knobelsdorff-Brenkenhoff, Florian; Karunaharamoorthy, Achudhan; Trauzeddel, Ralf Felix; Barker, Alex J; Blaszczyk, Edyta; Markl, Michael; Schulz-Menger, Jeanette
2016-01-01
Background Aortic stenosis (AS) leads to variable stress for the left ventricle (LV) and consequently a broad range of LV remodeling. Study aim was to describe blood flow patterns in the ascending aorta of AS patients and determine their association with remodeling. Methods and Results Thirty-seven patients with AS (14 mild, 8 moderate, 15 severe; age 63±13 years) and 37 healthy controls (age 60±10 years) underwent 4D-flow MRI. Helical and vortical flow formations and flow eccentricity were assessed in the ascending aorta. Normalized flow displacement from the vessel center and peak systolic wall shear stress (WSSpeak) in the ascending aorta were quantified. LV remodeling was assessed based on LV mass index (LVMI-I) and the ratio of LV mass to enddiastolic volume (relative wall mass; RWM). Marked helical and vortical flow formation and eccentricity were more prevalent in patients with AS than in healthy subjects, and AS patients exhibited an asymmetric and elevated distribution of WSSpeak. In AS, aortic orifice area was strongly negatively associated with vortical flow formation (p=0.0274), eccentricity (p=0.0070) and flow displacement (p=0.0021). Bicuspid aortic valve was associated with more intense helical (p=0.0098) and vortical flow formation (p=0.0536), higher flow displacement (p=0.11) and higher WSSpeak (p=0.0926). LVM-I and RWM were significantly associated with aortic orifice area (p=0.0611, p=0.0058) and flow displacement (p=0.0058, p=0.0283). Conclusions In this pilot study, AS leads to abnormal blood flow pattern and WSSpeak in the ascending aorta. In addition to aortic orifice area, normalized flow displacement was significantly associated with LV remodeling. PMID:26917824
Flexible margin kinematics and vortex formation of Aurelia aurita and Robojelly.
Villanueva, Alex; Vlachos, Pavlos; Priya, Shashank
2014-01-01
The development of a rowing jellyfish biomimetic robot termed as "Robojelly", has led to the discovery of a passive flexible flap located between the flexion point and bell margin on the Aurelia aurita. A comparative analysis of biomimetic robots showed that the presence of a passive flexible flap results in a significant increase in the swimming performance. In this work we further investigate this concept by developing varying flap geometries and comparing their kinematics with A. aurita. It was shown that the animal flap kinematics can be replicated with high fidelity using a passive structure and a flap with curved and tapered geometry gave the most biomimetic performance. A method for identifying the flap location was established by utilizing the bell curvature and the variation of curvature as a function of time. Flaps of constant cross-section and varying lengths were incorporated on the Robojelly to conduct a systematic study of the starting vortex circulation. Circulation was quantified using velocity field measurements obtained from planar Time Resolved Digital Particle Image Velocimetry (TRDPIV). The starting vortex circulation was scaled using a varying orifice model and a pitching panel model. The varying orifice model which has been traditionally considered as the better representation of jellyfish propulsion did not appear to capture the scaling of the starting vortex. In contrast, the pitching panel representation appeared to better scale the governing flow physics and revealed a strong dependence on the flap kinematics and geometry. The results suggest that an alternative description should be considered for rowing jellyfish propulsion, using a pitching panel method instead of the traditional varying orifice model. Finally, the results show the importance of incorporating the entire bell geometry as a function of time in modeling rowing jellyfish propulsion.
Gehring, J M; Cho, J-G; Wheatley, J R; Amis, T C
2014-03-01
We examined thermocouple and pressure cannulae responses to oral and nasal airflow using a polyester model of a human face, with patent nasal and oral orifices instrumented with a dual thermocouple (F-ONT2A, Grass) or a dual cannula (0588, Braebon) pressure transducer (± 10 cm H2O, Celesco) system. Tidal airflow was generated using a dual compartment facemask with pneumotachographs (Fleisch 2) connected to the model orifices. During nasal breathing: thermocouple amplitude = 0.38 Ln [pneumotachograph amplitude] + 1.31 and pressure cannula amplitude = 0.93 [pneumotachograph amplitude](2.15); during oral breathing: thermocouple amplitude = 0.44 Ln [pneumotachograph amplitude] + 1.07 and pressure cannula amplitude = 0.33 [pneumotachograph amplitude](1.72); (all range ∼ 0.1-∼ 4.0 L s(-1); r(2) > 0.7). For pneumotachograph amplitudes <1 L s(-1) (linear model) change in thermocouple amplitude/unit change in pneumotachograph amplitude was similar for nasal and oral airflow, whereas nasal pressure cannula amplitude/unit change in pneumotachograph amplitude was almost four times that for oral. Increasing oral orifice area from 0.33 cm(2) to 2.15 cm(2) increased oral thermocouple amplitude/unit change in pneumotachograph amplitude by ∼ 58% but decreased pressure cannula amplitude/unit change in pneumotachograph amplitude by 49%. For pneumotachograph amplitudes up to 1 L s(-1), alterations in inspiratory/expiratory ratios or total respiratory time did not affect the sensitivity of either nasal or oral pressure cannulae or the nasal thermocouple, but the oral thermocouple sensitivity was influenced by respiratory cycle time. Different nasal and oral responses influence the ability of these systems to quantitatively assess nasal and oral airflow and oro-nasal airflow partitioning.
Ichikawa, Makoto; Sato, Yuichi; Komatsu, Sei; Hirayama, Atsushi; Kodama, Kazuhisa; Saito, Satoshi
2007-06-01
Anomalous right coronary arteries (RCA) arising from the left sinus of Valsalva may cause myocardial ischemia. We evaluated morphological features of anomalous RCA by using multislice computed tomography (MSCT) in relation to myocardial ischemia provoked by myocardial perfusion single-photon emission computed tomography. MSCT was performed in a total of 3, 212 patients by using an Aquillion 16 and a Light Speed Ultra. Retrospective ECG-gated image reconstruction was performed. Volume rendering, axial and curved multiplanar reformatted images were analyzed for the determination of the origin and course of the RCA, the take-off angle of the RCA from the aorta, and size of the RCA orifice. Furthermore, virtual angioscopic images were also used for the evaluation of the RCA orifice structure. Anomalous origins of the RCA were found in 15 patients. In 13 patients, the RCA arose from the left sinus of Valsalva, and in 2 patients it arose from the left main coronary artery as a single coronary artery. The RCA coursed anteriorly between the ascending aorta and pulmonary artery in 14 patients, whereas it had a retroaortic course in 1 patient. Acute angle take-off (<30 degrees ) of the RCA from the aorta and the left main coronary artery was observed in 8 patients, intramural course of the RCA within the aortic wall was observed in 6 patients and a small RCA orifice was observed in 4 patients. Exercise-induced myocardial ischemia was present in 5 patients. Coursing between the aorta and pulmonary artery, acute angle take-off and intramural course were thought to be major causes of exercise-induced ischemia in patients with anomalous origins of the RCA.
The new Labcor-Santiago pericardial bioprosthesis.
Garcia-Bengochea, J B; Casagrande, I; Gonzalez-Juanatey, J R; Puig, L; Rubio, J; Duran, D; Sierra, J
1991-12-01
The Labcor-Santiago pericardial valve has been designed to minimize mechanical stress and to avoid abrasion wear, at the same time preserving the concept of mounting the pericardium outside the posts for full orifice opening. The new design has preserved the traditional superior hemodynamic performance of pericardial valves, avoiding abrasion by careful padding of the stents and introducing a new concept of cusp attachment in order to increase mechanical durability. Since June 1990, 40 patients received 46 Labcor-Santiago valves: 29 in the aortic position and 17 in the mitral position. Mean age was 65.6 years. Eighty percent of the patients were women. New York Heart Association Functional Class III-IV was present in 76% of patients. Hospital mortality has been 12.5%, with 31% undergoing concomitant procedures. No anticoagulation was administered and there has been one thromboembolic event. Echo-Doppler assessment yielded the following in the aortic position: effective orifice area for 19-mm size = 1 cm2; for 21-mm size = 1.2 cm2. Mean systolic gradient for 19-mm size = 14.7 mmHg; for 21-mm size = 11.2 mmHg. In the mitral position: effective orifice area for 27-mm size = 2 cm2; for 29-mm size = 2.3 cm2. Mean diastolic gradients for 27-mm size = 4.6 mmHg; for 29-mm size = 3.3 mmHg. The low-profile flexible stent, the streamlined shape without outside prosthetic material, and the anatomical sewing rim allow a comfortable implantation of the Labcor-Santiago valve, particularly in the small aortic annulus. It is hoped that this new design will contribute to an increase in in vivo mechanical durability.
Wei, Dechao; Han, Yili; Li, Mingchuan; Wang, Yongxing; Chen, Yatong; Luo, Yong; Jiang, Yongguang
2016-06-11
Among the different organs used for NOTES (natural orifice translumenal endoscopic surgery) technique, the transvaginal approach may be the optimal choice because of a simple and secure closure of colpotomy site. Pure and hybrid NOTES transvaginal operations were routinely performed via transperitoneal access. In this study, we investigate the safety and feasibility of pure retroperitoneal natural orifice translumenal endoscopic surgery (NOTES) transvaginal nephrectomy using conventional laparoscopic techniques in a porcine model. Six female pigs, weighing an average of 30 kg, were used in this study. Under general anesthesia, pure retroperitoneal NOTES transvaginal nephrectomy was conducted using standard laparoscopic instruments. Posterolateral colpotomy was performed, and the incision was enlarged laterally using blunt dissection and pneumatic dilation. A single-port device was inserted to construct the operative channel. The retroperitoneal space was created using sharp and blunt dissection under endoscopic guidance up to the level of the kidney. Dissection and removal of the kidney were performed according to standard surgical procedure, and the colpotomy site was closed using interrupted sutures. The survival and complications were observed 1 week postoperatively. Our results showed that two cases failed because of peritoneal rupture. One case was successful, but required the assistance of an extra 5 mm laparoscopic trocar inserted in the flank. Three cases of pure retroperitoneal NOTES transvaginal nephrectomy were completed, and survived 1 week after the operation. In these three cases, no intra- or postoperative complications were observed. All findings confirmed the safety and feasibility of the retroperitoneal pure retroperitoneal NOTES transvaginal nephrectomy using standard laparoscopic instruments, which suggested the possibility of clinical application in human beings in the future.
Peeters, Harry Huiz; De Moor, Roeland J G
2015-07-01
The use of Er,Cr:YSGG laser to activate irrigants results in the creation of vapour bubbles and shockwaves. The present study evaluated the magnitude of pressure changes in the root canal during laser-activated irrigation. The root canal of a single extracted maxillary canine was enlarged to a size 40/0.06 file. A pressure sensor was inserted apically into the root canal. The tooth was processed as follows. In the EDTA condition, the tooth was irrigated with 17 % EDTA; in the NaOCl condition, the tooth was irrigated with 3 % NaOCl. In all conditions, the irrigants were activated at 0.75 and 1.75 W for 60 s using RFT2 and MZ2 tips; to analyse the effect of tip placement, the tip was activated at the orifice and after inserting the tip 5 mm deeper than the orifice. Data showed no significant difference between irrigation regimens (p > 0.05). There were no significant differences of the pressure between RFT2 and MZ2 tips (p > 0.05). The placement of tips closer to the apex resulted in significantly higher pressure than at the orifice (p < 0.001). The use of 1.75 W power resulted in a significantly higher increase of pressure compared to 0.75 W (p < 0.001), regardless either the type of solutions or tips used. The magnitude of the pressure changes in the root canal at 0.75 W was significantly lower than 1.75 W regardless of either type of tips or solutions used. The closer the insertion of the tip to the apex, the higher the pressure.
Müller, S; Menciotti, G; Borgarelli, M
2017-10-01
To determine feasibility and repeatability of measuring the anatomic regurgitant orifice area (AROA) using real-time three-dimensional transthoracic echocardiography (RT3DE) in dogs with myxomatous mitral valve disease (MMVD), and to investigate differences in the AROA of dogs with different disease severity and in different American College of Veterinary Internal Medicine (ACVIM) stages. Sixty privately-owned dogs diagnosed with MMVD. The echocardiographic database of our institution was retrospectively searched for dogs diagnosed with MMVD and RT3DE data set acquisition. Dogs were classified into mild, moderate, or severe MMVD according to a Mitral Regurgitation Severity Score (MRSS), and into stage B1, B2 or C according to ACVIM staging. The RT3DE data sets were imported into dedicated software and a short axis plane crossing the regurgitant orifice was used to measure the AROA. Feasibility, inter- and intra-observer variability of measuring the AROA was calculated. Differences in the AROA between dogs in different MRSS and ACVIM stages were investigated. The AROA was measurable in 60 data sets of 81 selected to be included in the study (74%). The inter- and intra-observer coefficients of variation were 26% and 21%, respectively. The AROA was significantly greater in dogs with a severe MRSS compared with dogs with mild MRSS (p=0.045). There was no difference between the AROA of dogs in different ACVIM clinical stages. Obtaining the AROA using RT3DE is feasible and might provide additional information to stratify mitral regurgitation severity in dogs with MMVD. Diagnostic and prognostic utility of the AROA deserves further investigation. Copyright © 2017 Elsevier B.V. All rights reserved.
Tidholm, A; Bodegård-Westling, A; Höglund, K; Häggström, J; Ljungvall, I
2017-03-01
Effective regurgitant orifice area (EROA), calculated from the vena contracta width (VCW) as the narrowest portion of the proximal regurgitant jet, might be used to estimate severity of mitral regurgitation. However, this simplified assumption only holds when the EROA is circular, which might not be true in dogs with myxomatous mitral valve disease (MMVD). Effective regurgitant orifice area in dogs with MMVD is noncircular, and using color Doppler real-time 3-dimensional (RT3D) echocardiography, measured EROA in the en face view will be significantly different from calculated EROA. Hundred and fifty-eight privately owned dogs with naturally occurring MMVD. Prospective observational study comparing en face view of EROA with calculated EROA using VCW in 4-chamber (4Ch) and 2-chamber (2Ch) view only or combined 4Ch and 2Ch views using RT3D echocardiography. The calculated EROA using the 2Ch view showed a systematic underestimation of 17% compared with the measured en face EROA corrected for body surface area. The calculated EROA using 4Ch and 4Ch + 2Ch views showed less agreement with the en face EROA, and the difference between methods increased with increasing EROA. The difference between calculated and measured EROA showed a systematic underestimation of the calculated EROA by 36% (4Ch) and 33% (4Ch + 2Ch), respectively, compared to measured en face EROA. When replacing measured EROA with calculated EROA using VCW measurements, the 2Ch view is preferred in dogs with MMVD. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Hidalgo, Francisco; Mesa, Dolores; Ruiz, Martín; Delgado, Mónica; Rodríguez, Sara; Pardo, Laura; Pan, Manuel; López, Amador; Romero, Miguel A; Suárez de Lezo, José
2016-11-01
The percutaneous mitral valve repair procedure (MitraClip) appears to reduce mitral annulus diameter in patients with functional mitral regurgitation, but the relationship between this and regurgitation severity has not been demonstrated. The aim of this study was to determine the effect of mitral annulus remodeling on the reduction of mitral regurgitation in patients with functional etiology. The study included all patients with functional mitral regurgitation treated with MitraClip at our hospital until January 2015. Echocardiogram (iE33 model, Philips) was performed in all patients immediately after device positioning. Changes in the mitral annulus correlated with mitral regurgitation severity, as assessed using the effective regurgitant orifice area. The study included 23 patients (age, 65±14 years; 74% men; left ventricular ejection fraction, 31%±13%; systolic pulmonary artery pressure, 47±10 mmHg). After the procedure, the regurgitant orifice area decreased by 0.30 cm 2 ±0.04 cm 2 (P<.0005), from a baseline of 0.49 cm 2 ±0.09 cm 2 . Anteroposterior diameter decreased by 3.14 mm±1.01 mm (P<.0005) from a baseline of 28.27 mm±4.9 mm, with no changes in the intercommissural diameter (0.50 mm±0.91 mm vs 40.68 mm±4.7 mm; P=.26). A significant association was seen between anteroposterior diameter reduction and regurgitant orifice area reduction (r=.49; P=.020). In patients with functional mitral regurgitation, the MitraClip device produces an immediate reduction in the anteroposterior diameter. This remodeling may be related to the reduction in mitral regurgitation. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Fucci, Carlo; Faggiano, Pompilio; Nardi, Matilde; D'Aloia, Antonio; Coletti, Giuseppe; De Cicco, Giuseppe; Latini, Leonardo; Vizzardi, Enrico; Lorusso, Roberto
2013-09-10
Barlow disease represents a surgical challenge for mitral valve repair (MR) in the presence of mitral insufficiency (MI) with multiple regurgitant jets. We hereby present our mid-term experience using a modified edge-to-edge technique to address this peculiar MI. From March 2003 till December 2010, 25 consecutive patients (mean age 54 ± 7 years, 14 males) affected by severe Barlow disease with multiple regurgitant jets were submitted to MR. Preoperative transesophageal echo (TEE) in all the cases showed at least 2 regurgitant jets, involving one or both leaflets in more than one segment. In all the patients, a triple orifice valve (TOV) repair with annuloplasty was performed. Intra-operative TEE and postoperative transthoracic echocardiography (TTE) were carried out to evaluate results of the TOV repair. There was no in-hospital death and one late death (non-cardiac related). At intra-operative TEE, the three orifices showed a mean total valve area of 2.9 ± 0.1cm(2) (range 2.5-3.3 cm(2)) with no residual regurgitation (2 cases of trivial MI) and no sign of valve stenosis (mean transvalvular gradient 4.6 ± 1.5 mmHg). At follow up (mean 38 ± 22 months), TTE showed favourable MR and no recurrence of significant MI (6 cases of trivial and 1 of mild MI). Stress TTE was performed in 5 cases showing persistent effective valve function (2 cases of trivial MI at peak exercise). All the patients showed significant NYHA functional class improvement. This report indicates that the TOV technique is effective in correcting complex Barlow mitral valves with multiple jets. Further studies are required to confirm long-term applicability and durability in more numerous clinical cases. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Patency of the Internal Iliac Artery after Placement of Common and External Iliac Artery Stents.
Vinogradova, Margie; Lee, Hye Joon; Armstrong, Ehrin J; Laird, John; Humphries, Misty D
2017-01-01
Treatment of severe aortoiliac occlusive disease (AIOD) frequently requires long-segment stenting of the common and external iliac arteries (CIA and EIA, respectively). This study aims to analyze the patency of the internal iliac artery (IIA) after placement of a CIA and EIA stents across the orifice. A retrospective analysis of all patients who underwent de novo ipsilateral stent placement in the CIA and EIA between 2006 and 2013 was performed. Kaplan-Meier analysis was used to analyze patency of the IIA, and Cox proportional hazard models were used to identify characteristics associated with occlusion. We identified 77 patients and 93 limbs where ipsilateral CIA and EIA stents were placed. Preintervention angiographic review found 52 cases of a patent ipsilateral IIA where stents were placed across the origin of the IIA in 31 cases and staggered across the orifice in 20 limbs. Kaplan-Meier analysis demonstrated a 37% patency in limbs where the stent covered the IIA orifice compared to 78% patency in uncovered arteries (P = 0.04). New-onset buttock claudication developed in 4 patients, 2 with patent IIAs and 2 with occluded. New-onset impotence also developed in 3 patients with occluded IIA and 5 patients with patent IIAs. Placement of stents across the origin of the IIA may not result in immediate occlusion, but long-term patency of covered IIAs is decreased compared to uncovered IIAs. This study is limited by a small sample size, but when treating AIOD, coverage of the internal iliac origin should be avoided to maintain patency of the pelvic circulation. Copyright © 2016 Elsevier Inc. All rights reserved.
Experimental Study of an Inclined Jet-In-Cross-Flow Interacting with a Vortex Generator
NASA Technical Reports Server (NTRS)
Zaman, K. B. M. Q.; Rigby, D. L.; Heidmann, J. D.
2010-01-01
An experiment is conducted on the effectiveness of a vortex generator (VG) in preventing lift-off of a jet-in-cross-flow (JICF), with film-cooling application in mind. The jet issues into the boundary layer at an angle of 20 to the free-stream. The effect of a triangular ramp-shaped VG is studied while varying its geometry and location. Detailed flow-field properties are documented for a specific case in which the height of the VG and the diameter of the orifice are comparable to the approach boundary layer thickness. This combination of VG and JICF produce a streamwise vortex pair with vorticity magnitude three times larger (and of opposite sense) than that found in the JICF alone. Such a VG appears to be most effective in keeping the jet attached to the wall. While most of the data are taken at a jet-to-freestream momentum flux ratio (J) of 2, limited surveys are done for varying J. The VG is found to have a significant effect even at the highest J (=11) covered in the experiment. Effect of parametric variation is studied mostly from surveys ten diameters downstream from the orifice. When the VG height is halved there is a lift-off of the jet. On the other hand, when the height is doubled, the jet core is dissipated due to larger turbulence intensities. Varying the location of the VG, over a distance of three diameters from the orifice, is found to have little impact. Rounding off the edges of the VG with increasing radius of curvature progressively diminishes the effect. However, a small radius of curvature may be quite tolerable in practice.
Yasuda, Atsushi; Yasuda, Takushi; Kato, Hiroaki; Iwama, Mitsuru; Shiraishi, Osamu; Hiraki, Yoko; Tanaka, Yumiko; Shinkai, Masayuki; Imano, Motohiro; Kimura, Yutaka; Imamoto, Haruhiko
2017-12-01
An incisional hernia in a case of antethoracic pedicled jejunal flap esophageal reconstruction after esophagectomy is a very rare occurrence, and this hernia was distinctive in that the reconstructed jejunum had passed through the hernial orifice; a standard surgical treatment for such a presentation has not been established. Herein, we describe a case of repair using mesh prosthesis for an atypical and distinctive incisional hernia after antethoracic pedicled jejunal flap esophageal reconstruction. A 77-year-old woman with a history of subtotal esophagectomy who had undergone antethoracic pedicled jejunal flap reconstruction complained of epigastric prominence and discomfort without pain. On examination, she had an abdominal protrusion between the xiphoid process and the umbilicus that contained the small bowel. Computed tomography showed that the fenestration of the abdominal wall that was intentionally created for jejunum pull-up was dehisced in a region measuring 9 × 15 cm and the small intestine protruded through it into the subcutaneous space without strangulation. Because the hernial orifice was too large and the reconstructed jejunum was passing through the hernial orifice in this case, we applied a parastomal hernia repair method that was modified from the inguinal hernia repair using the Lichtenstein technique. After 3 years and 5 months following surgery, the patient has recovered without hernia recurrence or other complications. We consider this to be the first case of repair using Composix mesh prosthesis for repair of an atypical and distinctive incisional hernia after an antethoracic pedicled jejunal flap reconstruction. This method seems to be useful and could potentially be widely adopted as the surgical treatment for this condition.
FLOW TESTING AND ANALYSIS OF THE FSP-1 EXPERIMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hawkes, Grant L.; Jones, Warren F.; Marcum, Wade
The U.S. High Performance Research Reactor Conversions fuel development team is focused on developing and qualifying the uranium-molybdenum (U-Mo) alloy monolithic fuel to support conversion of domestic research reactors to low enriched uranium. Several previous irradiations have demonstrated the favorable behavior of the monolithic fuel. The Full Scale Plate 1 (FSP-1) fuel plate experiment will be irradiated in the northeast (NE) flux trap of the Advanced Test Reactor (ATR). This fueled experiment contains six aluminum-clad fuel plates consisting of monolithic U-Mo fuel meat. Flow testing experimentation and hydraulic analysis have been performed on the FSP-1 experiment to be irradiated inmore » the ATR at the Idaho National Laboratory (INL). A flow test experiment mockup of the FSP-1 experiment was completed at Oregon State University. Results of several flow test experiments are compared with analyses. This paper reports and shows hydraulic analyses are nearly identical to the flow test results. A water velocity of 14.0 meters per second is targeted between the fuel plates. Comparisons between FSP-1 measurements and this target will be discussed. This flow rate dominates the flow characteristics of the experiment and model. Separate branch flows have minimal effect on the overall experiment. A square flow orifice was placed to control the flowrate through the experiment. Four different orifices were tested. A flow versus delta P curve for each orifice is reported herein. Fuel plates with depleted uranium in the fuel meat zone were used in one of the flow tests. This test was performed to evaluate flow test vibration with actual fuel meat densities and reported herein. Fuel plate deformation tests were also performed and reported.« less