Sample records for orthopedic implant infection

  1. In-vivo orthopedic implant diagnostic device for sensing load, wear, and infection

    DOEpatents

    Evans, III, Boyd McCutchen; Thundat, Thomas G.; Komistek, Richard D.; Dennis, Douglas A.; Mahfouz, Mohamed

    2006-08-29

    A device for providing in vivo diagnostics of loads, wear, and infection in orthopedic implants having at least one load sensor associated with the implant, at least one temperature sensor associated with the implant, at least one vibration sensor associated with the implant, and at least one signal processing device operatively coupled with the sensors. The signal processing device is operable to receive the output signal from the sensors and transmit a signal corresponding with the output signal.

  2. Airport detection of implanted orthopedic devices.

    PubMed

    Ostrum, Robert F

    2006-10-01

    Since the attacks of September 11, 2001, the United States and other countries have increased airport security. Metal detectors (archway and handheld wand) are used to detect potentially dangerous instruments during airport screening. One consequence is that orthopedic implants are sometimes detected, and patients are detained and searched. The orthopedic literature is inconsistent in its reports on airport screening of patients with orthopedic implants. In this article, I review that literature and examine the factors that make detection of orthopedic implants a less than consistent science.

  3. EVALUATION OF THE KNOWLEDGE ON COST OF ORTHOPEDIC IMPLANTS AMONG ORTHOPEDIC SURGEONS

    PubMed Central

    Arliani, Gustavo Gonçalves; Sabongi, Rodrigo Guerra; Batista, Alysson Ferreira; Astur, Diego Costa; Falotico, Guilherme Guadagnini; Cohen, Moises

    2016-01-01

    ABSTRACT Objective: To determine the knowledge of Brazilian Orthopedic Surgeons on the costs of orthopedic surgical devices used in surgical implants. Methods: A questionnaire was applied to Brazilian Orthopedic Surgeons during the 46th Brazilian Congress on Orthopedics and Traumatology. Results: Two hundred and one Orthopedic Surgeons completely filled out the questionnaire. The difference between the average prices estimated by the surgeons and the average prices provided by the supplier companies was 47.1%. No differences were found between the orthopedic specialists and other subspecialties on the prices indicated for specific orthopedic implants. However, differences were found among orthopedic surgeons who received visits from representatives of implant companies and those who did not receive those visits on prices indicated for shaver and radiofrequency device. Correlation was found between length of orthopedic experience and prices indicated for shaver and interference screw, and higher the experience time the lower the price indicated by Surgeons for these materials. Conclusion: The knowledge of Brazilian Orthopedic Surgeons on the costs of orthopedic implants is precarious. Reduction of cost of orthopedics materials depends on a more effective communication and interaction between doctors, hospitals and supplier companies with solid orientation programs and awareness for physicians about their importance in this scenario.Level of Evidence III, Cross-Sectional Study. PMID:28243178

  4. Biological Strategies for Improved Osseointegration and Osteoinduction of Porous Metal Orthopedic Implants

    PubMed Central

    Riester, Scott M.; Bonin, Carolina A.; Kremers, Hilal Maradit; Dudakovic, Amel; Kakar, Sanjeev; Cohen, Robert C.; Westendorf, Jennifer J.

    2015-01-01

    The biological interface between an orthopedic implant and the surrounding host tissue may have a dramatic effect upon clinical outcome. Desired effects include bony ingrowth (osseointegration), stimulation of osteogenesis (osteoinduction), increased vascularization, and improved mechanical stability. Implant loosening, fibrous encapsulation, corrosion, infection, and inflammation, as well as physical mismatch may have deleterious clinical effects. This is particularly true of implants used in the reconstruction of load-bearing synovial joints such as the knee, hip, and the shoulder. The surfaces of orthopedic implants have evolved from solid-smooth to roughened-coarse and most recently, to porous in an effort to create a three-dimensional architecture for bone apposition and osseointegration. Total joint surgeries are increasingly performed in younger individuals with a longer life expectancy, and therefore, the postimplantation lifespan of devices must increase commensurately. This review discusses advancements in biomaterials science and cell-based therapies that may further improve orthopedic success rates. We focus on material and biological properties of orthopedic implants fabricated from porous metal and highlight some relevant developments in stem-cell research. We posit that the ideal primary and revision orthopedic load-bearing metal implants are highly porous and may be chemically modified to induce stem cell growth and osteogenic differentiation, while minimizing inflammation and infection. We conclude that integration of new biological, chemical, and mechanical methods is likely to yield more effective strategies to control and modify the implant–bone interface and thereby improve long-term clinical outcomes. PMID:25348836

  5. Using Aerospace Technology To Design Orthopedic Implants

    NASA Technical Reports Server (NTRS)

    Saravanos, D. A.; Mraz, P. J.; Davy, D. T.

    1996-01-01

    Technology originally developed to optimize designs of composite-material aerospace structural components used to develop method for optimizing designs of orthopedic implants. Development effort focused on designing knee implants, long-term goal to develop method for optimizing designs of orthopedic implants in general.

  6. Hydrogel delivery of lysostaphin eliminates orthopedic implant infection by Staphylococcus aureus and supports fracture healing

    PubMed Central

    Johnson, Christopher T.; Wroe, James A.; Agarwal, Rachit; Martin, Karen E.; Guldberg, Robert E.; Donlan, Rodney M.; Westblade, Lars F.; García, Andrés J.

    2018-01-01

    Orthopedic implant infections are a significant clinical problem, with current therapies limited to surgical debridement and systemic antibiotic regimens. Lysostaphin is a bacteriolytic enzyme with high antistaphylococcal activity. We engineered a lysostaphin-delivering injectable PEG hydrogel to treat Staphylococcus aureus infections in bone fractures. The injectable hydrogel formulation adheres to exposed tissue and fracture surfaces, ensuring efficient, local delivery of lysostaphin. Lysostaphin encapsulation within this synthetic hydrogel maintained enzyme stability and activity. Lysostaphin-delivering hydrogels exhibited enhanced antibiofilm activity compared with soluble lysostaphin. Lysostaphin-delivering hydrogels eradicated S. aureus infection and outperformed prophylactic antibiotic and soluble lysostaphin therapy in a murine model of femur fracture. Analysis of the local inflammatory response to infections treated with lysostaphin-delivering hydrogels revealed indistinguishable differences in cytokine secretion profiles compared with uninfected fractures, demonstrating clearance of bacteria and associated inflammation. Importantly, infected fractures treated with lysostaphin-delivering hydrogels fully healed by 5 wk with bone formation and mechanical properties equivalent to those of uninfected fractures, whereas fractures treated without the hydrogel carrier were equivalent to untreated infections. Finally, lysostaphin-delivering hydrogels eliminate methicillin-resistant S. aureus infections, supporting this therapy as an alternative to antibiotics. These results indicate that lysostaphin-delivering hydrogels effectively eliminate orthopedic S. aureus infections while simultaneously supporting fracture repair. PMID:29760099

  7. Hydrogel delivery of lysostaphin eliminates orthopedic implant infection by Staphylococcus aureus and supports fracture healing.

    PubMed

    Johnson, Christopher T; Wroe, James A; Agarwal, Rachit; Martin, Karen E; Guldberg, Robert E; Donlan, Rodney M; Westblade, Lars F; García, Andrés J

    2018-05-29

    Orthopedic implant infections are a significant clinical problem, with current therapies limited to surgical debridement and systemic antibiotic regimens. Lysostaphin is a bacteriolytic enzyme with high antistaphylococcal activity. We engineered a lysostaphin-delivering injectable PEG hydrogel to treat Staphylococcus aureus infections in bone fractures. The injectable hydrogel formulation adheres to exposed tissue and fracture surfaces, ensuring efficient, local delivery of lysostaphin. Lysostaphin encapsulation within this synthetic hydrogel maintained enzyme stability and activity. Lysostaphin-delivering hydrogels exhibited enhanced antibiofilm activity compared with soluble lysostaphin. Lysostaphin-delivering hydrogels eradicated S. aureus infection and outperformed prophylactic antibiotic and soluble lysostaphin therapy in a murine model of femur fracture. Analysis of the local inflammatory response to infections treated with lysostaphin-delivering hydrogels revealed indistinguishable differences in cytokine secretion profiles compared with uninfected fractures, demonstrating clearance of bacteria and associated inflammation. Importantly, infected fractures treated with lysostaphin-delivering hydrogels fully healed by 5 wk with bone formation and mechanical properties equivalent to those of uninfected fractures, whereas fractures treated without the hydrogel carrier were equivalent to untreated infections. Finally, lysostaphin-delivering hydrogels eliminate methicillin-resistant S. aureus infections, supporting this therapy as an alternative to antibiotics. These results indicate that lysostaphin-delivering hydrogels effectively eliminate orthopedic S. aureus infections while simultaneously supporting fracture repair. Copyright © 2018 the Author(s). Published by PNAS.

  8. Effect of Antibiotic Prophylaxis on Surgical Site Infections Following Removal of Orthopedic Implants Used for Treatment of Foot, Ankle, and Lower Leg Fractures: A Randomized Clinical Trial.

    PubMed

    Backes, Manouk; Dingemans, Siem A; Dijkgraaf, Marcel G W; van den Berg, H Rogier; van Dijkman, Bart; Hoogendoorn, Jochem M; Joosse, Pieter; Ritchie, Ewan D; Roerdink, W Herbert; Schots, Judith P M; Sosef, Nico L; Spijkerman, Ingrid J B; Twigt, Bas A; van der Veen, Alexander H; van Veen, Ruben N; Vermeulen, Jefrey; Vos, Dagmar I; Winkelhagen, Jasper; Goslings, J Carel; Schepers, Tim

    2017-12-26

    Following clean (class I, not contaminated) surgical procedures, the rate of surgical site infection (SSI) should be less than approximately 2%. However, an infection rate of 12.2% has been reported following removal of orthopedic implants used for treatment of fractures below the knee. To evaluate the effect of a single dose of preoperative antibiotic prophylaxis on the incidence of SSIs following removal of orthopedic implants used for treatment of fractures below the knee. Multicenter, double-blind, randomized clinical trial including 500 patients aged 18 to 75 years with previous surgical treatment for fractures below the knee who were undergoing removal of orthopedic implants from 19 hospitals (17 teaching and 2 academic) in the Netherlands (November 2014-September 2016), with a follow-up of 6 months (final follow-up, March 28, 2017). Exclusion criteria were an active infection or fistula, antibiotic treatment, reimplantation of osteosynthesis material in the same session, allergy for cephalosporins, known kidney disease, immunosuppressant use, or pregnancy. A single preoperative intravenous dose of 1000 mg of cefazolin (cefazolin group, n = 228) or sodium chloride (0.9%; saline group, n = 242). Primary outcome was SSI within 30 days as measured by the criteria from the US Centers for Disease Control and Prevention. Secondary outcome measures were functional outcome, health-related quality of life, and patient satisfaction. Among 477 randomized patients (mean age, 44 years [SD, 15]; women, 274 [57%]; median time from orthopedic implant placement, 11 months [interquartile range, 7-16]), 470 patients completed the study. Sixty-six patients developed an SSI (14.0%): 30 patients (13.2%) in the cefazolin group vs 36 in the saline group (14.9%) (absolute risk difference, -1.7 [95% CI, -8.0 to 4.6], P = .60). Among patients undergoing surgery for removal of orthopedic implants used for treatment of fractures below the knee, a single preoperative dose of

  9. Immobilized antibiotics to prevent orthopedic implant infections

    PubMed Central

    Hickok, Noreen J.; Shapiro, Irving M.

    2012-01-01

    Many surgical procedures require the placement of an inert or tissue-derived implant deep within the body cavity. While the majority of these implants do not become colonized by bacteria, a small percentage develops a biofilm layer that harbors invasive microorganisms. In orthopaedic surgery, unresolved periprosthetic infections can lead to implant loosening, arthrodeses, amputations and sometimes death. The focus of this review is to describe development of an implant in which an antibiotic tethered to the metal surface is used to prevent bacterial colonization and biofilm formation. Building on well-established chemical syntheses, studies show that antibiotics can be linked to titanium through a self-assembled monolayer of siloxy amines. The stable metal-antibiotic construct resists bacterial colonization and biofilm formation while remaining amenable to osteoblastic cell adhesion and maturation. In an animal model, the antibiotic modified implant resists challenges by bacteria that are commonly present in periprosthetic infections. While the long-term efficacy and stability is still to be established, ongoing studies support the view that this novel type of bioactive surface has a real potential to mitigate or prevent the devastating consequences of orthopaedic infection. PMID:22512927

  10. Metallic artifact in MRI after removal of orthopedic implants.

    PubMed

    Bagheri, Mohammad Hadi; Hosseini, Mehrdad Mohammad; Emami, Mohammad Jafar; Foroughi, Amin Aiboulhassani

    2012-03-01

    The aim of the present study was to evaluate the metallic artifacts in MRI of the orthopedic patients after removal of metallic implants. From March to August 2009, 40 orthopedic patients operated for removal of orthopedic metallic implants were studied by post-operative MRI from the site of removal of implants. A grading scale of 0-3 was assigned for artifact in MR images whereby 0 was considered no artifact; and I-III were considered mild, moderate, and severe metallic artifacts, respectively. These grading records were correlated with other variables including the type, size, number, and composition of metallic devices; and the site and duration of orthopedic devices stay in the body. Metallic susceptibly artifacts were detected in MRI of 18 of 40 cases (45%). Screws and pins in removed hardware were the most important factors for causing artifacts in MRI. The artifacts were found more frequently in the patients who had more screws and pins in the removed implants. Gender, age, site of implantation of the device, length of the hardware, composition of the metallic implants (stainless steel versus titanium), and duration of implantation of the hardware exerted no effect in producing metallic artifacts after removal of implants. Short TE sequences of MRI (such as T1 weighted) showed fewer artifacts. Susceptibility of metallic artifacts is a frequent phenomenon in MRI of patients upon removal of metallic orthopedic implants. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  11. Effect of a preoperative decontamination protocol on surgical site infections in patients undergoing elective orthopedic surgery with hardware implantation.

    PubMed

    Bebko, Serge P; Green, David M; Awad, Samir S

    2015-05-01

    Surgical site infections (SSIs), commonly caused by methicillin-resistant Staphylococcus aureus (MRSA), are associated with significant morbidity and mortality, specifically when hardware is implanted in the patient. Previously, we have demonstrated that a preoperative decontamination protocol using chlorhexidine gluconate washcloths and intranasal antiseptic ointment is effective in eradicating MRSA in the nose and on the skin of patients. To examine the effect of a decontamination protocol on SSIs in patients undergoing elective orthopedic surgery with hardware implantation. A prospective database of patients undergoing elective orthopedic surgery with hardware implantation at the Michael E. DeBakey Veterans Affairs Medical Center in Houston, Texas, was analyzed from October 1, 2012, to December 31, 2013. Cohort groups before and after the intervention were compared. Starting in May 2013, during their preoperative visit, all of the patients watched an educational video about MRSA decontamination and were given chlorhexidine washcloths and oral rinse and nasal povidone-iodine solution to be used the night before and the morning of scheduled surgery. Thirty-day SSI rates were collected according to the definitions of the Centers for Disease Control and Prevention National Nosocomial Infections Surveillance. Data on demographics, comorbidities such as chronic obstructive pulmonary disease and coronary artery disease, tobacco use, alcohol use, and body mass index were also collected. Univariate analysis was performed between the 2 groups of patients. Multivariate analysis was used to identify independent predictors of SSI. A total of 709 patients were analyzed (344 controls and 365 patients who were decolonized). Both groups were well matched with no significant differences in age, body mass index, sex, or comorbidities. All of the patients (100%) completed the MRSA decontamination protocol. The SSI rate in the intervention group was significantly lower (1.1%; 4 of

  12. Infection of orthopedic implants with emphasis on bacterial adhesion process and techniques used in studying bacterial-material interactions

    PubMed Central

    Ribeiro, Marta; Monteiro, Fernando J.; Ferraz, Maria P.

    2012-01-01

    Staphylococcus comprises up to two-thirds of all pathogens in orthopedic implant infections and they are the principal causative agents of two major types of infection affecting bone: septic arthritis and osteomyelitis, which involve the inflammatory destruction of joint and bone. Bacterial adhesion is the first and most important step in implant infection. It is a complex process influenced by environmental factors, bacterial properties, material surface properties and by the presence of serum or tissue proteins. Properties of the substrate, such as chemical composition of the material, surface charge, hydrophobicity, surface roughness and the presence of specific proteins at the surface, are all thought to be important in the initial cell attachment process. The biofilm mode of growth of infecting bacteria on an implant surface protects the organisms from the host immune system and antibiotic therapy. The research for novel therapeutic strategies is incited by the emergence of antibiotic-resistant bacteria. This work will provide an overview of the mechanisms and factors involved in bacterial adhesion, the techniques that are currently being used studying bacterial-material interactions as well as provide insight into future directions in the field. PMID:23507884

  13. RAPID MANUFACTURING SYSTEM OF ORTHOPEDIC IMPLANTS

    PubMed Central

    Relvas, Carlos; Reis, Joana; Potes, José Alberto Caeiro; Fonseca, Fernando Manuel Ferreira; Simões, José Antonio Oliveira

    2015-01-01

    This study, aimed the development of a methodology for rapid manufacture of orthopedic implants simultaneously with the surgical intervention, considering two potential applications in the fields of orthopedics: the manufacture of anatomically adapted implants and implants for bone loss replacement. This work innovation consists on the capitation of the in situ geometry of the implant by direct capture of the shape using an elastomeric material (polyvinylsiloxane) which allows fine detail and great accuracy of the geometry. After scanning the elastomeric specimen, the implant is obtained by machining using a CNC milling machine programmed with a dedicated CAD/CAM system. After sterilization, the implant is able to be placed on the patient. The concept was developed using low cost technology and commercially available. The system has been tested in an in vivo hip arthroplasty performed on a sheep. The time increase of surgery was 80 minutes being 40 minutes the time of implant manufacturing. The system developed has been tested and the goals defined of the study achieved enabling the rapid manufacture of an implant in a time period compatible with the surgery time. PMID:27004181

  14. Contributing risk factors for orthopedic device related infections in sina hospital, tehran, iran.

    PubMed

    Hadadi, A; Zehtab, M J; Babagolzadeh, H; Ashraf, H

    2011-02-01

    In spite of decreasing incidence of orthopedic device-related infections to 1%, nowadays, device-related infection still remains a diagnostic, therapeutic and cost-related problem. The objective of this study is to evaluate the contributing risk factors for orthopedic device-related infections in Sina Hospital, Tehran, Iran. Three hundred and thirty patients who underwent orthopedic device implantation from 2002-2006 were enrolled; among them, 110 patients were complicated with infection. Descriptive and logistic regression analyses were performed to determine the risk factors for device related infections. Patients with infection were older compared to those without infection. The Staphylococcus aureus was the commonest organism. A correlation was observed between wound infection and external fixation, an underlying health condition, and addiction which were independent risk factors for a device related infection. Orthopedic device-related infection puts a great financial burden on patients and hospital resources and could lead to morbidity and mortality in patients. So, appropriate pre and postoperative wound care for dirty wounds, especially when external fixators are used, and in patients with poor conditions or addiction should be done with more caution.

  15. Porous metal for orthopedics implants

    PubMed Central

    Matassi, Fabrizio; Botti, Alessandra; Sirleo, Luigi; Carulli, Christian; Innocenti, Massimo

    2013-01-01

    Summary Porous metal has been introduced to obtain biological fixation and improve longevity of orthopedic implants. The new generation of porous metal has intriguing characteristics that allows bone healing and high osteointegration of the metallic implants. This article gives an overview about biomaterials properties of the contemporary class of highly porous metals and about the clinical use in orthopaedic surgery. PMID:24133527

  16. ANALYSIS OF SURGICAL SITE INFECTIONS IN PEDIATRIC PATIENTS AFTER ORTHOPEDIC SURGERY: A CASE-CONTROL STUDY

    PubMed Central

    Chagas, Mariana de Queiroz Leite; Costa, Ana Maria Magalhães; Mendes, Pedro Henrique Barros; Gomes, Saint Clair

    2017-01-01

    ABSTRACT Objectives: To describe the rate of surgical site infections in children undergoing orthopedic surgery in centers of excellence and analyze the patients’ profiles. Methods: Medical records of pediatric patients undergoing orthopedic surgery in the Jamil Haddad National Institute of Traumatology and Orthopedics from January 2012 to December 2013 were analyzed and monitored for one year. Patients diagnosed with surgical site infection were matched with patients without infection by age, date of admission, field of orthopedic surgery and type of surgical procedure. Patient, surgical and follow-up variables were examined. Descriptive, bivariate and correspondence analyses were performed to evaluate the patients’ profiles. Results: 347 surgeries and 10 surgical site infections (2.88%) were identified. There was association of infections with age - odds ratio (OR) 11.5 (confidence interval - 95%CI 1.41-94.9) -, implant - OR 7.3 (95%CI 1.46-36.3) -, preoperative period - OR 9.8 (95%CI 1.83-53.0), and length of hospitalization - OR 20.6 (95%CI 3.7-114.2). The correspondence analysis correlated the infection and preoperative period, weight, weight Z-score, age, implant, type of surgical procedure, and length of hospitalization. Average time to diagnosis of infection occurred 26.5±111.46 days after surgery. Conclusions: The rate of surgical site infection was 2.88%, while higher in children over 24 months of age who underwent surgical implant procedures and had longer preoperative periods and lengths of hospitalization. This study identified variables for the epidemiological surveillance of these events in children. Available databases and appropriate analysis methods are essential to monitor and improve the quality of care offered to the pediatric population. PMID:28977312

  17. A touch probe method of operating an implantable RFID tag for orthopedic implant identification.

    PubMed

    Liu, Xiaoyu; Berger, J Lee; Ogirala, Ajay; Mickle, Marlin H

    2013-06-01

    The major problem in operating an implantable radio-frequency identification (RFID) tag embedded on an orthopedic implant is low efficiency because of metallic interference. To improve the efficiency, this paper proposes a method of operating an implantable passive RFID tag using a touch probe at 13.56 MHz. This technology relies on the electric field interaction between two pairs of electrodes, one being a part of the touch probe placed on the surface of tissue and the other being a part of the tag installed under the tissue. Compared with using a conventional RFID antenna such as a loop antenna, this method has a better performance in the near field operation range to reduce interference with the orthopedic implant. Properly matching the touch probe and the tag to the tissue and the implant reduces signal attenuation and increases the overall system efficiency. The experiments have shown that this method has a great performance in the near field transcutaneous operation and can be used for orthopedic implant identification.

  18. Superelastic Orthopedic Implant Coatings

    NASA Astrophysics Data System (ADS)

    Fournier, Eric; Devaney, Robert; Palmer, Matthew; Kramer, Joshua; El Khaja, Ragheb; Fonte, Matthew

    2014-07-01

    The demand for hip and knee replacement surgery is substantial and growing. Unfortunately, most joint replacement surgeries will fail within 10-25 years, thereby requiring an arduous, painful, and expensive revision surgery. To address this issue, a novel orthopedic implant coating material ("eXalt") has been developed. eXalt is comprised of super elastic nitinol wire that is knit into a three-dimensional spacer fabric structure. eXalt expands in vivo to conform to the implantation site and is porous to allow for bone ingrowth. The safety and efficacy of eXalt were evaluated through structural analysis, mechanical testing, and a rabbit implantation model. The results demonstrate that eXalt meets or exceeds the performance of current coating technologies with reduced micromotion, improved osseointegration, and stronger implant fixation in vivo.

  19. Clinical potential of implantable wireless sensors for orthopedic treatments.

    PubMed

    Karipott, Salil Sidharthan; Nelson, Bradley D; Guldberg, Robert E; Ong, Keat Ghee

    2018-04-01

    Implantable wireless sensors have been used for real-time monitoring of chemicals and physical conditions of bones, tendons and muscles to diagnose and study orthopedic diseases and injuries. Due to the importance of these sensors in orthopedic care, a critical review, which not only analyzes the underlying technologies but also their clinical implementations and challenges, will provide a landscape view on their current state and their future clinical role. Areas covered: By conducting an extensive literature search and following the leaders of orthopedic implantable wireless sensors, this review covers the battery-powered and battery-free wireless implantable sensor technologies, and describes their implementation for hips, knees, spine, and shoulder stress/strain monitoring. Their advantages, limitations, and clinical challenges are also described. Expert commentary: Currently, implantable wireless sensors are mostly limited for scientific investigations and demonstrative experiments. Although rapid advancement in sensors and wireless technologies will push the reliability and practicality of these sensors for clinical realization, regulatory constraints and financial viability in medical device industry may curtail their continuous adoption for clinical orthopedic applications. In the next five years, these sensors are expected to gain increased interest from researchers, but wide clinical adoption is still unlikely.

  20. 78 FR 17940 - Certain Computerized Orthopedic Surgical Devices, Software, Implants, and Components Thereof...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-25

    ..., Software, Implants, and Components Thereof; Notice of Receipt of Complaint; Solicitation of Comments... Certain Computerized Orthopedic Surgical Devices, Software, Implants, and Components Thereof, DN 2945; the... importation of certain computerized orthopedic surgical devices, software, implants, and components thereof...

  1. Biomechanical and bioactivity concepts of polyetheretherketone composites for use in orthopedic implants-a review.

    PubMed

    Abdullah, Mohamed Ruslan; Goharian, Amirhossein; Abdul Kadir, Mohammed Rafiq; Wahit, Mat Uzir

    2015-11-01

    The use of polyetheretherketone (PEEK) composites in the trauma plating system, total replacement implants, and tissue scaffolds has found great interest among researchers. In recent years (2008 afterward), this type of composites has been examined for suitability as substitute material over stainless steel, titanium alloys, ultra high molecular weight polyethylene, or even biodegradable materials in orthopedic implant applications. Biomechanical and bioactivity concepts were contemplated for the development of PEEK orthopedic implants and a few primary clinical studies reported the clinical outcomes of PEEK-based orthopedic implants. This study aims to review and discuss the recent concepts and contribute further concepts in terms of biomechanical and bioactivity challenges for the development of PEEK and PEEK composites in orthopedic implants. © 2015 Wiley Periodicals, Inc.

  2. Persistence of bacterial DNA in orthopedic infections.

    PubMed

    Kaplan, Heidi B; Miranda, Justin A; Gogola, Gloria R; Gomez, Karen; Ambrose, Catherine G

    2018-06-01

    Polymerase chain reaction (PCR) has been proposed as a method to identify bacteria in clinical samples because it is more sensitive than culture techniques and can produce results rapidly. However, PCR can detect DNA from dead cells and thus cannot distinguish between live and dead cells in a tissue sample. Killed Staphylococcus aureus cells were implanted into the femurs and knee joints of rats to determine the length of time that DNA from dead cells is detectable in a living animal under conditions similar to common orthopedic infections. In the joint infection model studied here, the DNA from the dead planktonic bacteria was detected using PCR immediately after injection or 24 h later, but was undetectable 48 and 72 h after injection. In the biofilm implanted-device model studied, the DNA from these dead biofilm cells was detected by PCR immediately after implantation and at 24 h, but not at 48 or 72 h. Thus, our results indicate that DNA from dead cells does not persist in these animal model systems for more than 2 days, which should reduce concerns about possible false positive results using molecular DNA-based techniques for the detection of pathogens. Copyright © 2018. Published by Elsevier Inc.

  3. Orthopedic implant devices: prevalence and sociodemographic findings from the 1988 National Health Interview Survey.

    PubMed

    Moore, R M; Hamburger, S; Jeng, L L; Hamilton, P M

    1991-01-01

    National population-based estimates on the magnitude and distribution of orthopedic implant devices in the United States have not been available to date. The Food and Drug Administration's Center for Devices and Radiological Health (FDA/CDRH) collaborated with the Centers for Disease Control's National Center for Health Statistics (CDC/NCHS) in the design and conduct of a nationwide medical device implant survey to generate the first national population-based prevalence estimates of orthopedic implant devices. A Medical Device Implant Supplement to the 1988 National Health Interview Survey was administered in personal household interviews to a national sample of 47,485 households, which included 122,310 individuals. An estimated 6.5 million orthopedic implants were in use in the general US population in 1988, including 1.6 million artificial joints and 4.9 million fixation devices. As a group, orthopedic implants comprised nearly half of all medical device implants in use, 43.4%. The majority of artificial joint recipients were 65 years of age or older, white, and male. The majority of fixation device recipients were less than 45 years of age, white, and male. The limitations and strengths of these population-based estimates are discussed.

  4. Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants

    PubMed Central

    Amini, Ami R.; Wallace, James S.; Nukavarapu, Syam P.

    2012-01-01

    Presently, orthopedic and oral/maxillofacial implants represent a combined $2.8 billion market, a figure expected to experience significant and continued growth. Although traditional permanent implants have been proved clinically efficacious, they are also associated with several drawbacks, including secondary revision and removal surgeries. Non-permanent, biodegradable implants offer a promising alternative for patients, as they provide temporary support and degrade at a rate matching tissue formation, and thus, eliminate the need for secondary surgeries. These implants have been in clinical use for nearly 25 years, competing directly with, or maybe even exceeding, the performance of permanent implants. The initial implantation of biodegradable materials, as with permanent materials, mounts an acute host inflammatory response. Over time, the implant degradation profile and possible degradation product toxicity mediate long-term biodegradable implant-induced inflammation. However, unlike permanent implants, this inflammation is likely to cease once the material disappears. Implant-mediated inflammation is a critical determinant for implant success. Thus, for the development of a proactive biodegradable implant that has the ability to promote optimal bone regeneration and minimal detrimental inflammation, a thorough understanding of short- and long-term inflammatory events is required. Here, we discuss an array of biodegradable orthopedic implants, their associated short- and long- term inflammatory effects, and methods to mediate these inflammatory events. PMID:22043969

  5. Optimal Irrigation and Debridement of Infected Joint Implants

    PubMed Central

    Schwechter, Evan M.; Folk, David; Varshney, Avanish K.; Fries, Bettina C.; Kim, Sun Jin; Hirsh, David M.

    2014-01-01

    Acute postoperative and acute, late hematogenous prosthetic joint infections have been treated with 1-stage irrigation and debridement with polyethylene exchange. Success rates, however, are highly variable. Reported studies demonstrate that detergents are effective at decreasing bacterial colony counts on orthopedic implants. Our hypothesis is that the combination of a detergent and an antiseptic would be more effective than using a detergent alone to decrease colony counts from a methicillin-resistant Staphylococcus aureus biofilm-coated titanium alloy disk simulating an orthopedic implant. In our study of various agents tested, chlorhexidine gluconate scrub (antiseptic and detergent) was the most effective at decreasing bacterial colony counts both prereincubation and postreincubation of the disks; pulse lavage and scrubbing were not more effective than pulse lavage alone. PMID:21641757

  6. Massive subacromial-subdeltoid bursitis with rice bodies secondary to an orthopedic implant.

    PubMed

    Urruela, Adriana M; Rapp, Timothy B; Egol, Kenneth A

    2012-09-01

    Both early and late complications following open reduction and internal fixation of proximal humerus fractures have been reported extensively in the literature. Although orthopedic implants are known to cause irritation and inflammation, to our knowledge, this is the first case report to describe a patient with rice bodies secondary to an orthopedic implant. Although the etiology of rice bodies is unclear, histological studies reveal that they are composed of an inner amorphous core surrounded by collagen and fibrin. The differential diagnosis in this case included synovial chondromatosis, infection, and the formation of a malignant tumor. Additional imaging studies, such as magnetic resonance imaging, and more specific tests were necessary to differentiate the rice bodies due to bursitis versus neoplasm, prior to excision. The patient presented 5 years following open reduction and internal fixation of a displaced proximal humerus fracture, with swelling in the area of the previous surgical site. Examination revealed a large, painless tumor-like mass on the anterior aspect of the shoulder. The patient's chief concern was the unpleasant aesthetic of the mass; no pain was reported. Upon excision of the mass, the patient's full, painless range of motion returned.

  7. A controlled antibiotic release system to prevent orthopedic-implant associated infections: An in vitro study

    PubMed Central

    Gimeno, Marina; Pinczowski, Pedro; Pérez, Marta; Giorello, Antonella; Martínez, Miguel Ángel; Santamaría, Jesús; Arruebo, Manuel; Luján, Lluís

    2015-01-01

    A new device for local delivery of antibiotics is presented, with potential use as a drug-eluting fixation pin for orthopedic applications. The implant consists of a stainless steel hollow tubular reservoir packed with the desired antibiotic. Release takes place through several orifices previously drilled in the reservoir wall, a process that does not compromise the mechanical properties required for the implant. Depending on the antibiotic chosen and the number of orifices, the release profile can be tailored from a rapid release of the load (ca. 20 h) to a combination of rapid initial release and slower, sustained release for a longer period of time (ca. 200 h). An excellent bactericidal action is obtained, with 4-log reductions achieved in as little as 2 h, and total bacterial eradication in 8 h using 6-pinholed implants filled with cefazolin. PMID:26297104

  8. Value of PCR in sonication fluid for the diagnosis of orthopedic hardware-associated infections: Has the molecular era arrived?

    PubMed

    Renz, Nora; Cabric, Sabrina; Morgenstern, Christian; Schuetz, Michael A; Trampuz, Andrej

    2018-04-01

    Bone healing disturbance following fracture fixation represents a continuing challenge. We evaluated a novel fully automated polymerase chain reaction (PCR) assay using sonication fluid from retrieved orthopedic hardware to diagnose infection. In this prospective diagnostic cohort study, explanted orthopedic hardware materials from consecutive patients were investigated by sonication and the resulting sonication fluid was analyzed by culture (standard procedure) and multiplex PCR (investigational procedure). Hardware-associated infection was defined as visible purulence, presence of a sinus tract, implant on view, inflammation in peri-implant tissue or positive culture. McNemar's chi-squared test was used to compare the performance of diagnostic tests. For the clinical performance all pathogens were considered, whereas for analytical performance only microorganisms were considered for which primers are included in the PCR assay. Among 51 patients, hardware-associated infection was diagnosed in 38 cases (75%) and non-infectious causes in 13 patients (25%). The sensitivity for diagnosing infection was 66% for peri-implant tissue culture, 84% for sonication fluid culture, 71% (clinical performance) and 77% (analytical performance) for sonication fluid PCR, the specificity of all tests was >90%. The analytical sensitivity of PCR was higher for gram-negative bacilli (100%), coagulase-negative staphylococci (89%) and Staphylococcus aureus (75%) than for Cutibacterium (formerly Propionibacterium) acnes (57%), enterococci (50%) and Candida spp. (25%). The performance of sonication fluid PCR for diagnosis of orthopedic hardware-associated infection was comparable to culture tests. The additional advantage of PCR was short processing time (<5 h) and fully automated procedure. With further improvement of the performance, PCR has the potential to complement conventional cultures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Novel Antibacterial Coating on Orthopedic Wires To Eliminate Pin Tract Infections

    PubMed Central

    Gil, Dmitry; Shuvaev, Sergey; Frank-Kamenetskii, Anastasia; Reukov, Vladimir; Gross, Christopher

    2017-01-01

    ABSTRACT Novel approaches to the prevention of microbial infections after the insertion of orthopedic external fixators are in great demand because of the extremely high incidence rates of such infections, which can reach up to 100% with longer implant residence times. Monolaurin is an antimicrobial agent with a known safety record that is broadly used in the food and cosmetic industries; however, its use in antimicrobial coatings of medical devices has not been studied in much detail. Here, we report the use of monolaurin as an antibacterial coating on external fixators for the first time. Monolaurin-coated Kirschner wires (K-wires) showed excellent antibacterial properties against three different bacterial strains, i.e., methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant Staphylococcus aureus (MRSA), and Staphylococcus epidermidis. Approximately 6.0-log reductions of both planktonic and adherent bacteria were achieved using monolaurin-coated K-wires, but monolaurin-coated K-wires did not show any observable cytotoxicity with mouse osteoblast cell cultures. Overall, monolaurin-coated K-wires could be promising as potent antimicrobial materials for orthopedic surgery. PMID:28483964

  10. The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review

    PubMed Central

    Li, Chuan Silvia; Vannabouathong, Christopher; Sprague, Sheila; Bhandari, Mohit

    2015-01-01

    Carbon-fiber-reinforced polyetheretherketone (CFR-PEEK) has been successfully used in orthopedic implants. The aim of this systematic review is to investigate the properties, technical data, and safety of CFR-PEEK biomaterial and to evaluate its potential for new innovation in the design of articulating medical devices. A comprehensive search in PubMed and EMBASE was conducted to identify articles relevant to the outcomes of CFR-PEEK orthopedic implants. The search was also expanded by reviewing the reference sections of selected papers and references and benchmark reports provided by content experts. A total of 23 articles were included in this review. There is limited literature available assessing the performance of CFR-PEEK, specifically as an implant material for arthroplasty systems. Nevertheless, available studies strongly support CFR-PEEK as a promising and suitable material for orthopedic implants because of its biocompatibility, material characteristics, and mechanical durability. Future studies should continue to investigate CFR-PEEK’s potential benefits. PMID:25780341

  11. Readability of Patient Education Materials From the Web Sites of Orthopedic Implant Manufacturers.

    PubMed

    Yi, Meghan M; Yi, Paul H; Hussein, Khalil I; Cross, Michael B; Della Valle, Craig J

    2017-12-01

    Prior studies indicate that orthopedic patient education materials are written at a level that is too high for the average patient. The purpose of this study was to assess the readability of online patient education materials provided by orthopedic implant manufacturers. All patient education articles available in 2013 from the web sites of the 5 largest orthopedic implant manufacturers were identified. Each article was evaluated with the Flesch-Kincaid (FK) readability test. The number of articles with readability ≤ the eighth-grade level (average reading ability of US adults) and the sixth-grade level (recommended level for patient education materials) was determined. Mean readability levels of each company's articles were compared using analysis of variance (significance set at P < .05). A total of 581 articles were reviewed from the 5 largest implant manufacturers. The mean overall FK grade level was 10.9 (range, 3.8-16.1). Only 58 articles (10%) were written ≤ the eighth-grade level, and only 13 (2.2%) were ≤ the sixth-grade level. The mean FK grade level was significantly different among groups (Smith & Nephew = 12.0, Stryker = 11.6, Biomet = 11.3, DePuy = 10.6, Zimmer = 10.1; P < .0001). The majority of patient education materials from implant manufacturers are written at a level too high to be comprehended by the average patient. Future efforts should be made to improve the readability of orthopedic patient education materials. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Adaptation of NASA technology for the optimization of orthopedic knee implants

    NASA Technical Reports Server (NTRS)

    Saravanos, D. A.; Mraz, P. J.; Hopkins, D. A.

    1991-01-01

    The NASA technology originally developed for the optimization of composite structures (engine blades) is adapted and applied to the optimization of orthopedic knee implants. A method is developed enabling the tailoring of the implant for optimal interaction with the environment of the tibia. The shape of the implant components are optimized, such that the stresses in the bone are favorably controlled to minimize bone degradation and prevent failures. A pilot tailoring system is developed and the feasibility of the concept is elevated. The optimization system is expected to provide the means for improving knee prosthesis and individual implant tailoring for each patient.

  13. Development and Evaluation of Polyvinyl Alcohol-Hydrogels as an Artificial Atrticular Cartilage for Orthopedic Implants

    PubMed Central

    Kobayashi, Masanori; Hyu, Hyon Suong

    2010-01-01

    Due to its excellent biocompatibility and mechanical properties, various different applications of polyvinyl alcohol-hydrogels (PVA-H) has been attempted in many fields. In the field of orthopedic surgery, we have been engaged for long time in research on the clinical applications of PVA-H as a artificial cartilage, and have performed many basic experiments on the mechanical properties, synthesis of PVA-H, and developed orthopedic implants using PVA-H. From these studies, many applications of artificial articular cartilage, intervertbral disc and artificial meniscus etc. have been developed. This review will present the overview of the applications and recent advances of PVA-H cartilages, and discuss clinical potential of PVA-H for orthopedics implant.

  14. Can Direct Current Electrotherapy Be Used for Patients With Orthopedic Implants?

    PubMed Central

    Thaler, Evangeline; Korte, Holger

    2017-01-01

    Introduction: Although electrotherapy appears to have particularly interesting applications in the field of postoperative orthopedic rehabilitation, relatively little scientifically based research has been conducted in the area of electrotherapy with regard to safety involving patients with orthopedic implants. Method: Three electrotherapy forms were tested, such as high-volt stimulation (HVS), transcutaneous electric nerve stimulation (TENS), and galvanic current (GAL), using a model system containing a metal implant plate to evaluate whether heating in excess of 3°C would occur. Results: All changes in temperature for HVS, GAL, and TENS therapeutic electrical currents observed in our model system fall below the predefined 3°C. Conclusion: To the best of our knowledge, this is the first experimental based observation that prolonged exposure to a direct electrical current at therapeutic strength does not result in heating of metal titanium plates. PMID:28255511

  15. Power harvesting using PZT ceramics embedded in orthopedic implants.

    PubMed

    Chen, Hong; Liu, Ming; Jia, Chen; Wang, Zihua

    2009-09-01

    Battery lifetime has been the stumbling block for many power-critical or maintenance-free real-time embedded applications, such as wireless sensors and orthopedic implants. Thus a piezoelectric material that could convert human motion into electrical energy provides a very attractive solution for clinical implants. In this work, we analyze the power generation characteristics of stiff lead zirconate titanate (PZT) ceramics and the equivalent circuit through extensive experiments. Our experimental framework allows us to explore many important design considerations of such a PZT-based power generator. Overall we can achieve a PZT element volume of 0.5 x 0.5 x 1.8 cm, which is considerably smaller than the results reported so far. Finally, we outline the application of our PZT elements in a total knee replacement (TKR) implant.

  16. [Infections in orthopedics and traumatology. Pathogenesis and therapy].

    PubMed

    Scheffer, D; Hofmann, S; Pietsch, M; Wenisch, C

    2008-07-01

    Infections in orthopedics and traumatology are particularly challenging for the treating physician due to changing epidemiology and bacteriology, in particular immunosenescent patients and antimicrobial resistance. Numerous exogenous and endogenous factors contribute to the onset of bone/joint infection. Known clinical entities include osteitis/osteomyelitis, arthritis, prosthesis-associated infection and spondylitis/spondylodiscitis. Knowledge of epidemiology, bacteriology, and clinic and healing processes in infections leads to a better understanding of the various treatment strategies. Cephalosporin, fosfomycin, glycopeptide, lincosamide, oxazolidinones, ansamycins und fusidic acids represent the standard therapeutic agents in orthopedics and traumatology. Fluoroquinolones, glycylcyclines and lipopeptides are new and possibly promising alternatives. The most important indices of antibiotic agents used in everyday practice are discussed. In complicated cases, collaboration with a specialist for infectious diseases results in improved therapeutic results.

  17. Bioactive glass coatings for orthopedic metallic implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez-Esteban, Sonia; Saiz, Eduardo; Fujino, Sigheru

    2003-06-30

    The objective of this work is to develop bioactive glass coatings for metallic orthopedic implants. A new family of glasses in the SiO2-Na2O-K2O-CaO-MgO-P2O5 system has been synthesized and characterized. The glass properties (thermal expansion, softening and transformation temperatures, density and hardness) are in line with the predictions of established empirical models. The optimized firing conditions to fabricate coatings on Ti-based and Co-Cr alloys have been determined and related to the glass properties and the interfacial reactions. Excellent adhesion to alloys has been achieved through the formation of 100-200 nm thick interfacial layers (Ti5Si3 on Ti-based alloys and CrOx on Co-Cr).more » Finally, glass coatings, approximately 100 mu m thick, have been fabricated onto commercial Ti alloy-based dental implants.« less

  18. Disaster Victim Identification using Orthopedic Implants in the 2011 East-Japan Earthquake and Tsunami.

    PubMed

    Numata, Norio; Makinae, Haruka; Yoshida, Wataru; Daimon, Masao; Murakami, Hideki

    2017-03-01

    On March 11, 2011, an earthquake (magnitude 9.0) devastated Japan's east coast, and the associated tsunami resulted in social and mechanical destruction. Search for the missing people is still ongoing. Surgical implants are common in the general population. Medical implants usually have lot numbers, and their forensic use is common for victim identification. This investigation was conducted mainly in the cities of Kamaishi and Otsuchi, both of which were affected by the tsunami disaster in 2011. We visited 6 mortuaries with the police between March 20 (9 days after the tsunami) and April 20 (40 days after the tsunami) to examine the presence of surgical scars and related information. Unidentified human remains were investigated by visual and tactile examination. We also visited temples where the ashes were preserved. If implants were found, their lot numbers and estimated surgical procedures were recorded to determine positive identification. Ten of 233 sets of unidentified human remains before cremation displayed characteristics of a potential past surgical history. However, only 2 of these 233 sets had orthopedic implants. Instead, non-combustible orthopedic implants were found and recognized in 8 of the 331 sets of unidentified human ashes in the temples after cremation; the lot numbers were fully legible in 2 of the 8 sets. We estimated the surgical procedures, which led to positive identification. In conclusion, lot numbers and the surgical knowledge of orthopedic surgeons could assist with the positive identification of disaster victims. However, the relevant information can be erased after cremation.

  19. Atomic layer deposition of nano-TiO2 thin films with enhanced biocompatibility and antimicrobial activity for orthopedic implants

    PubMed Central

    Liu, Luting; Bhatia, Ritwik; Webster, Thomas J

    2017-01-01

    Titanium (Ti) and its alloys have been extensively used as implant materials in orthopedic applications. Nevertheless, implants may fail due to a lack of osseointegration and/or infection. The aim of this in vitro study was to endow an implant surface with favorable biological properties by the dual modification of surface chemistry and nanostructured topography. The application of a nanostructured titanium dioxide (TiO2) coating on Ti-based implants has been proposed as a potential way to enhance tissue-implant interactions while inhibiting bacterial colonization simultaneously due to its chemical stability, biocompatibility, and antimicrobial properties. In this paper, temperature-controlled atomic layer deposition (ALD) was introduced for the first time to provide unique nanostructured TiO2 coatings on Ti substrates. The effect of nano-TiO2 coatings with different morphology and structure on human osteoblast and fibroblast functions and bacterial activities was investigated. In vitro results indicated that the TiO2 coating stimulated osteoblast adhesion and proliferation while suppressing fibroblast adhesion and proliferation compared to uncoated materials. In addition, the introduction of nano-TiO2 coatings was shown to inhibit gram-positive bacteria (Staphylococcus aureus), gram-negative bacteria (Escherichia coli), and antibiotic-resistant bacteria (methicillin-resistant Staphylococcus aureus), all without resorting to the use of antibiotics. Our results suggest that the increase in nanoscale roughness and greater surface hydrophilicity (surface energy) together could contribute to increased protein adsorption selectively, which may affect the cellular and bacterial activities. It was found that ALD-grown TiO2-coated samples with a moderate surface energy at 38.79 mJ/m2 showed relatively promising antibacterial properties and desirable cellular functions. The ALD technique provides a novel and effective strategy to produce TiO2 coatings with delicate control

  20. Brandon Research, Inc. Orthopedic Implant Cooperative Research and Development Agreement (CRADA) Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freeman, W.R.

    1999-04-22

    The project was a joint research effort between the U. S. Department of Energy's (DOE) Kansas City Plant (KCP) and Brandon Research, Inc. to develop ways to improve implants used for orthopedic surgery for joint replacement. The primary product produced by this study is design information, which may be used to develop implants that will improve long-term fixation and durability in the host bone environment.

  1. PEEK Biomaterials in Trauma, Orthopedic, and Spinal Implants

    PubMed Central

    Kurtz, S. M.; Devine, J. N.

    2007-01-01

    Since the 1980s, polyaryletherketones (PAEKs) have been increasingly employed as biomaterials for trauma, orthopedic, and spinal implants. We have synthesized the extensive polymer science literature as it relates to structure, mechanical properties, and chemical resistance of PAEK biomaterials. With this foundation, one can more readily appreciate why this family of polymers will be inherently strong, inert, and biocompatible. Due to its relative inertness, PEEK biomaterials are an attractive platform upon which to develop novel bioactive materials, and some steps have already been taken in that direction, with the blending of HA and TCP into sintered PEEK. However, to date, blended HA-PEEK composites have involved a trade-off in mechanical properties in exchange for their increased bioactivity. PEEK has had the greatest clinical impact in the field of spine implant design, and PEEK is now broadly accepted as a radiolucent alternative to metallic biomaterials in the spine community. For mature fields, such as total joint replacements and fracture fixation implants, radiolucency is an attractive but not necessarily critical material feature. PMID:17686513

  2. Anodization: a promising nano-modification technique of titanium implants for orthopedic applications.

    PubMed

    Yao, Chang; Webster, Thomas J

    2006-01-01

    Anodization is a well-established surface modification technique that produces protective oxide layers on valve metals such as titanium. Many studies have used anodization to produce micro-porous titanium oxide films on implant surfaces for orthopedic applications. An additional hydrothermal treatment has also been used in conjunction with anodization to deposit hydroxyapatite on titanium surfaces; this is in contrast to using traditional plasma spray deposition techniques. Recently, the ability to create nanometer surface structures (e.g., nano-tubular) via anodization of titanium implants in fluorine solutions have intrigued investigators to fabricate nano-scale surface features that mimic the natural bone environment. This paper will present an overview of anodization techniques used to produce micro-porous titanium oxide structures and nano-tubular oxide structures, subsequent properties of these anodized titanium surfaces, and ultimately their in vitro as well as in vivo biological responses pertinent for orthopedic applications. Lastly, this review will emphasize why anodized titanium structures that have nanometer surface features enhance bone forming cell functions.

  3. Design and Validation of Implantable Passive Mechanisms for Orthopedic Surgery

    DTIC Science & Technology

    2017-10-01

    have post-surgery? Please put the designated grading next to each picture. 2. When comparing to the force applied by the index finger, what percentage...system, when compared with using the direct suture. This concept is inspired by the use of such mechanisms in the design of “underactuated” robotic...AWARD NUMBER: W81XWH-16-1-0794 TITLE: Design and Validation of Implantable Passive Mechanisms for Orthopedic Surgery PRINCIPAL INVESTIGATOR

  4. Engineered Chimeric Peptides as Antimicrobial Surface Coating Agents toward Infection-Free Implants

    PubMed Central

    Yazici, Hilal; O'Neill, Mary B.; Kacar, Turgay; Wilson, Brandon R.; Oren, E. Emre; Sarikaya, Mehmet; Tamerler, Candan

    2016-01-01

    Prevention of bacterial colonization and consequent biofilm formation remains a major challenge in implantable medical devices. Implant-associated infections are not only a major cause of implant failures but also their conventional treatment with antibiotics brings further complications due to the escalation in multidrug resistance to a variety of bacterial species. Owing to their unique properties, antimicrobial peptides (AMPs) have gained significant attention as effective agents to combat colonization of microorganisms. These peptides have been shown to exhibit a wide spectrum of activities with specificity to a target cell while having a low tendency for developing bacterial resistance. Engineering biomaterial surfaces that feature AMP properties, therefore, offer a promising approach to prevent implant infections. Here, we engineered a chimeric peptide with bifunctionality that both forms a robust solid-surface coating while presenting antimicrobial property. The individual domains of the chimeric peptides were evaluated for their solid-binding kinetics to titanium substrate as well as for their antimicrobial properties in solution. The antimicrobial efficacy of the chimeric peptide on the implant material was evaluated in vitro against infection by a variety of bacteria, including Streptococcus mutans, Staphylococcus. epidermidis, and Escherichia coli, which are commonly found in oral and orthopedic implant related surgeries. Our results demonstrate significant improvement in reducing bacterial colonization onto titanium surfaces below the detectable limit. Engineered chimeric peptides with freely displayed antimicrobial domains could be a potential solution for developing infection-free surfaces by engineering implant interfaces with highly reduced bacterial colonization property. PMID:26795060

  5. Engineered Chimeric Peptides as Antimicrobial Surface Coating Agents toward Infection-Free Implants.

    PubMed

    Yazici, Hilal; O'Neill, Mary B; Kacar, Turgay; Wilson, Brandon R; Oren, E Emre; Sarikaya, Mehmet; Tamerler, Candan

    2016-03-02

    Prevention of bacterial colonization and consequent biofilm formation remains a major challenge in implantable medical devices. Implant-associated infections are not only a major cause of implant failures but also their conventional treatment with antibiotics brings further complications due to the escalation in multidrug resistance to a variety of bacterial species. Owing to their unique properties, antimicrobial peptides (AMPs) have gained significant attention as effective agents to combat colonization of microorganisms. These peptides have been shown to exhibit a wide spectrum of activities with specificity to a target cell while having a low tendency for developing bacterial resistance. Engineering biomaterial surfaces that feature AMP properties, therefore, offer a promising approach to prevent implant infections. Here, we engineered a chimeric peptide with bifunctionality that both forms a robust solid-surface coating while presenting antimicrobial property. The individual domains of the chimeric peptides were evaluated for their solid-binding kinetics to titanium substrate as well as for their antimicrobial properties in solution. The antimicrobial efficacy of the chimeric peptide on the implant material was evaluated in vitro against infection by a variety of bacteria, including Streptococcus mutans, Staphylococcus. epidermidis, and Escherichia coli, which are commonly found in oral and orthopedic implant related surgeries. Our results demonstrate significant improvement in reducing bacterial colonization onto titanium surfaces below the detectable limit. Engineered chimeric peptides with freely displayed antimicrobial domains could be a potential solution for developing infection-free surfaces by engineering implant interfaces with highly reduced bacterial colonization property.

  6. Prevention of Infection in Orthopedic Prosthetic Surgery.

    PubMed

    Chirca, Ioana; Marculescu, Camelia

    2017-06-01

    Total joint arthroplasty is a generally safe orthopedic procedure; however, infection is a potentially devastating complication. Multiple risk factors have been identified for development of prosthetic joint infections. Identification of patients at risk and preoperative correction of known risk factors, such as smoking, diabetes mellitus, anemia, malnutrition, and decolonization of Staphylococcus carriers, represent well-established actions to decrease the infection risk. Careful operative technique, proper draping and skin preparation, and appropriate selection and dosing of antimicrobials for perioperative prophylaxis are also very important in prevention of infection. Published by Elsevier Inc.

  7. Surface Functionalization of Orthopedic Titanium Implants with Bone Sialoprotein

    PubMed Central

    Ritz, Ulrike; Ackermann, Angelika; Anthonissen, Joris; Kaufmann, Kerstin B.; Brendel, Christian; Götz, Hermann; Rommens, Pol M.; Hofmann, Alexander

    2016-01-01

    Orthopedic implant failure due to aseptic loosening and mechanical instability remains a major problem in total joint replacement. Improving osseointegration at the bone-implant interface may reduce micromotion and loosening. Bone sialoprotein (BSP) has been shown to enhance bone formation when coated onto titanium femoral implants and in rat calvarial defect models. However, the most appropriate method of BSP coating, the necessary level of BSP coating, and the effect of BSP coating on cell behavior remain largely unknown. In this study, BSP was covalently coupled to titanium surfaces via an aminosilane linker (APTES), and its properties were compared to BSP applied to titanium via physisorption and untreated titanium. Cell functions were examined using primary human osteoblasts (hOBs) and L929 mouse fibroblasts. Gene expression of specific bone turnover markers at the RNA level was detected at different intervals. Cell adhesion to titanium surfaces treated with BSP via physisorption was not significantly different from that of untreated titanium at any time point, whereas BSP application via covalent coupling caused reduced cell adhesion during the first few hours in culture. Cell migration was increased on titanium disks that were treated with higher concentrations of BSP solution, independent of the coating method. During the early phases of hOB proliferation, a suppressive effect of BSP was observed independent of its concentration, particularly when BSP was applied to the titanium surface via physisorption. Although alkaline phosphatase activity was reduced in the BSP-coated titanium groups after 4 days in culture, increased calcium deposition was observed after 21 days. In particular, the gene expression level of RUNX2 was upregulated by BSP. The increase in calcium deposition and the stimulation of cell differentiation induced by BSP highlight its potential as a surface modifier that could enhance the osseointegration of orthopedic implants. Both

  8. Application of computer graphics in the design of custom orthopedic implants.

    PubMed

    Bechtold, J E

    1986-10-01

    Implementation of newly developed computer modelling techniques and computer graphics displays and software have greatly aided the orthopedic design engineer and physician in creating a custom implant with good anatomic conformity in a short turnaround time. Further advances in computerized design and manufacturing will continue to simplify the development of custom prostheses and enlarge their niche in the joint replacement market.

  9. Delayed Propionibacterium acnes surgical site infections occur only in the presence of an implant

    PubMed Central

    Shiono, Yuta; Ishii, Ken; Nagai, Shigenori; Kakinuma, Hiroaki; Sasaki, Aya; Funao, Haruki; Kuramoto, Tetsuya; Yoshioka, Kenji; Ishihama, Hiroko; Isogai, Norihiro; Takeshima, Kenichiro; Tsuji, Takashi; Okada, Yasunori; Koyasu, Shigeo; Nakamura, Masaya; Toyama, Yoshiaki; Aizawa, Mamoru; Matsumoto, Morio

    2016-01-01

    Whether Propionibacterium acnes (P. acnes) causes surgical-site infections (SSI) after orthopedic surgery is controversial. We previously reported that we frequently find P. acnes in intraoperative specimens, yet none of the patients have clinically apparent infections. Here, we tracked P. acnes for 6 months in a mouse osteomyelitis model. We inoculated P. acnes with an implant into the mouse femur in the implant group; the control group was treated with the bacteria but no implant. We then observed over a 6-month period using optical imaging system. During the first 2 weeks, bacterial signals were detected in the femur in the both groups. The bacterial signal completely disappeared in the control group within 28 days. Interestingly, in the implant group, bacterial signals were still present 6 months after inoculation. Histological and scanning electron-microscope analyses confirmed that P. acnes was absent from the control group 6 months after inoculation, but in the implant group, the bacteria had survived in a biofilm around the implant. PCR analysis also identified P. acnes in the purulent effusion from the infected femurs in the implant group. To our knowledge, this is the first report showing that P. acnes causes SSI only in the presence of an implant. PMID:27615686

  10. Application of the finite element method in orthopedic implant design.

    PubMed

    Saha, Subrata; Roychowdhury, Amit

    2009-01-01

    The finite element method (FEM) was first introduced to the field of orthopedic biomechanics in the early 1970s to evaluate stresses in human bones. By the early 1980s, the method had become well established as a tool for basic research and design analysis. Since the late 1980s and early 1990s, FEM has also been used to study bone remodeling. Today, it is one of the most reliable simulation tools for evaluating wear, fatigue, crack propagation, and so forth, and is used in many types of preoperative testing. Since the introduction of FEM to orthopedic biomechanics, there have been rapid advances in computer processing speeds, the finite element and other numerical methods, understanding of mechanical properties of soft and hard tissues and their modeling, and image-processing techniques. In light of these advances, it is accepted today that FEM will continue to contribute significantly to further progress in the design and development of orthopedic implants, as well as in the understanding of other complex systems of the human body. In the following article, different main application areas of finite element simulation will be reviewed including total hip joint arthroplasty, followed by the knee, spine, shoulder, and elbow, respectively.

  11. How to Choose between the Implant Materials Steel and Titanium in Orthopedic Trauma Surgery: Part 2 - Biological Aspects.

    PubMed

    Perren, S M; Regazzoni, P; Fernandez, A A

    2017-01-01

    BIOLOGICAL ASPECTS OF STEEL AND TITANIUM AS IMPLANT MATERIAL IN ORTHOPEDIC TRAUMA SURGERY The following case from the ICUC database, where a titanium plate was implanted into a flourishing infection, represents the clinical experience leading to preferring titanium over steel. (Fig. 1) (6). Current opinions regarding biological aspects of implant function. The "street" opinions regarding the biological aspects of the use of steel versus titanium as a surgical trauma implant material differ widely. Statements of opinion leaders range from "I do not see any difference in the biological behavior between steel and titanium in clinical application" to "I successfully use titanium implants in infected areas in a situation where steel would act as foreign body "sustaining" infection." Furthermore, some comments imply that clinical proof for the superiority of titanium in human application is lacking. The following tries to clarify the issues addressing the different aspects more through a practical clinical approach than a purely scientific one, this includes simplifications. Today's overall biocompatibility of implant materials is acceptable but: As the vast majority of secondary surgeries are elective procedures this allows the selection of implant materials with optimal infection resistance. The different biological reactions of stainless steel and titanium are important for this segment of clinical pathologies. Biological tole - rance (18) depends on the toxicity and on the amount of soluble implant material released. Release, diffusion and washout through blood circulation determine the local concentration of the corrosion products. Alloying components of steel, especially nickel and chromium, are less than optimal in respect to tissue tolerance and allergenicity. Titanium as a pure metal provides excellent biological tolerance (3, 4, 16). Better strength was obtained by titanium alloys like TiAl6V4. The latter found limited application as surgical implants. It

  12. Nanotechnology: the scope and potential applications in orthopedic surgery.

    PubMed

    Gavaskar, Ashok; Rojas, D; Videla, F

    2018-03-30

    Nanotechnology involves manipulation of matter measuring 1-100 nm in at least one of its dimensions at the molecular level. Engineering and manipulation of matter at the molecular level has several advantages in the field of medicine (nanomedicine) since most of the biological molecules exist and function at a nanoscale. Though promising, questions still remain on how much of this will ultimately translate into achieving better patient care. Concerns of cost-effectiveness and nanotechnology safety still remain unclear. Orthopedics is an attractive area for the application of nanotechnology since the bone, and its constituents such as hydroxyapatite, Haversian systems, and the collagen fibrils are nanocompounds. The major orthopedic applications of nanotechnology involve around (i) effective drug delivery systems for antibiotics and chemotherapeutic agents, (ii) surface preparation of implants and prosthesis to improve osteointegration and reduce biofilm formation, (iii) controlled drug eluting systems to combat implant-related infections, (iv) tissue engineering for scaffolds preparation to deal with bone and cartilage defects, and (v) diagnostic applications in the field of oncology and musculoskeletal infections.

  13. The effect of chronic orthopedic infection on quality of life.

    PubMed

    Cheatle, M D

    1991-07-01

    The patient with chronic orthopedic infection presents a unique challenge to the orthopedic surgeon. The orthopedic surgeon must not only possess an expertise in constantly evolving diagnostic and treatment techniques but also be able to identify numerous related problems and direct the patient in receiving the most appropriate treatment. This demands a commitment of time by the treating surgeon to the individual patient to properly assess the need for support, the extent of psychologic distress, the intensity of pain, and the requirement for medication management. The effective utilization of a multidisciplinary team of health care providers (e.g., specialists in infectious disease, physical medicine and rehabilitation, psychiatry, nursing, pharmacology) can provide an optimal treatment program for this multifaceted problem and maximize the potential for a favorable outcome.

  14. Nanoparticulate zinc oxide as a coating material for orthopedic and dental implants.

    PubMed

    Memarzadeh, Kaveh; Sharili, Amir S; Huang, Jie; Rawlinson, Simon C F; Allaker, Robert P

    2015-03-01

    Orthopedic and dental implants are prone to infection. In this study, we describe a novel system using zinc oxide nanoparticles (nZnO) as a coating material to inhibit bacterial adhesion and promote osteoblast growth. Electrohydrodynamic atomisation (EHDA) was employed to deposit mixtures of nZnO and nanohydroxyapatite (nHA) onto the surface of glass substrates. Nano-coated substrates were exposed to Staphylococcus aureus suspended in buffered saline or bovine serum to determine antimicrobial activity. Our results indicate that 100% nZnO and 75% nZnO/25% nHA composite-coated substrates have significant antimicrobial activity. Furthermore, osteoblast function was explored by exposing cells to nZnO. UMR-106 cells exposed to nZnO supernatants showed minimal toxicity. Similarly, MG-63 cells cultured on nZnO substrates did not show release of TNF-α and IL-6 cytokines. These results were reinforced by both proliferation and differentiation studies which revealed that a substrate coated with exclusively nZnO is more efficient than composite surface coatings. Finally, electron and light microscopy, together with immunofluorescence staining, revealed that all cell types tested, including human mesenchymal cell (hMSC), were able to maintain normal cell morphology when adhered onto the surface of the nano-coated substrates. Collectively, these findings indicate that nZnO can, on its own, provide an optimal coating for future bone implants that are both antimicrobial and biocompatible. © 2014 Wiley Periodicals, Inc.

  15. Atomic Layer Deposition of a Silver Nanolayer on Advanced Titanium Orthopedic Implants Inhibits Bacterial Colonization and Supports Vascularized de Novo Bone Ingrowth.

    PubMed

    Devlin-Mullin, Aine; Todd, Naomi M; Golrokhi, Zahra; Geng, Hua; Konerding, Moritz A; Ternan, Nigel G; Hunt, John A; Potter, Richard J; Sutcliffe, Chris; Jones, Eric; Lee, Peter D; Mitchell, Christopher A

    2017-06-01

    Joint replacement surgery is associated with significant morbidity and mortality following infection with either methicillin-resistant Staphylococcus aureus (MRSA) or Staphylococcus epidermidis. These organisms have strong biofilm-forming capability in deep wounds and on prosthetic surfaces, with 10 3 -10 4 microbes resulting in clinically significant infections. To inhibit biofilm formation, we developed 3D titanium structures using selective laser melting and then coated them with a silver nanolayer using atomic layer deposition. On bare titanium scaffolds, S. epidermidis growth was slow but on silver-coated implants there were significant further reductions in both bacterial recovery (p < 0.0001) and biofilm formation (p < 0.001). MRSA growth was similarly slow on bare titanium scaffolds and not further affected by silver coating. Ultrastructural examination and viability assays using either human bone or endothelial cells, demonstrated strong adherence and growth on titanium-only or silver-coated implants. Histological, X-ray computed microtomographic, and ultrastructural analyses revealed that silver-coated titanium scaffolds implanted into 2.5 mm defects in rat tibia promoted robust vascularization and conspicuous bone ingrowth. We conclude that nanolayer silver of titanium implants significantly reduces pathogenic biofilm formation in vitro, facilitates vascularization and osseointegration in vivo making this a promising technique for clinical orthopedic applications. © 2017 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. An overview of recent advances in designing orthopedic and craniofacial implants

    PubMed Central

    Mantripragada, Venkata P.; Lecka-Czernik, Beata; Ebraheim, Nabil A.; Jayasuriya, Ambalangodage C.

    2016-01-01

    Great deal of research is still going on in the field of orthopedic and craniofacial implant development to resolve various issues being faced by the industry today. Despite several disadvantages of the metallic implants, they continue to be used, primarily because of their superior mechanical properties. In order to minimize the harmful effects of the metallic implants and its by-products, several modifications are being made to these materials, for instance nickel-free stainless steel, cobalt-chromium and titanium alloys are being introduced to eliminate the toxic effects of nickel being released from the alloys, introduce metallic implants with lower modulus, reduce the cost of these alloys by replacing rare elements with less expensive elements etc. New alloys like tantalum, niobium, zirconium, and magnesium are receiving attention given their satisfying mechanical and biological properties. Non-oxide ceramics like silicon nitride and silicon carbide are being currently developed as a promising implant material possessing a combination of properties such as good wear and corrosion resistance, increased ductility, good fracture and creep resistance, and relatively high hardness in comparison to alumina. Polymer/magnesium composites are being developed to improve mechanical properties as well as retain polymer’s property of degradation. Recent advances in orthobiologics are proving interesting as well. This paper thus deals with the latest improvements being made to the existing implant materials and includes new materials being introduced in the field of biomaterials. PMID:23766134

  17. Orthobiologics in Pediatric Orthopedics.

    PubMed

    Murphy, Robert F; Mooney, James F

    2017-07-01

    Orthobiologics are biologic devices or products used in orthopedic surgery to augment or enhance bone formation. The use of orthobiologics in pediatric orthopedics is less frequent than in other orthopedic subspecialties, mainly due to the naturally abundant healing potential and bone formation in children compared with adults. However, orthobiologics are used in certain situations in pediatric orthopedics, particularly in spine and foot surgery. Other uses have been reported in conjunction with specific procedures involving the tibia and pelvis. The use of bioabsorable implants to stabilize children's fractures is an emerging concept but has limited supporting data. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Bioactive ceramic coating on orthopedic implants for enhanced bone tissue integration

    NASA Astrophysics Data System (ADS)

    Aniket

    Tissue integration between bone and orthopedic implant is essential for implant fixation and longevity. An immunological response leads to fibrous encapsulation of metallic implants leading to implant instability and failure. Bioactive ceramics have the ability to directly bond to bone; however, they have limited mechanical strength for load bearing applications. Coating bioactive ceramics on metallic implant offers the exciting opportunity to enhance bone formation without compromising the mechanical strength of the implant. In the present study, we have developed a novel bioactive silica-calcium phosphate nanocomposite (SCPC) coating on medical grade Ti-6Al-4V orthopedic implant using electrophoretic deposition (EPD) and evaluated bone tissue response to the coated implant at the cellular level. The effect of SCPC composition and suspending medium pH on the zeta potential of three different SCPC formulations; SCPC25, SCPC50 and SCPC75 were analyzed. The average zeta potential of SCPC50 in pure ethanol was more negative than that of SCPC25 or SCPC75; however the difference was not statistically significant. Ti-6Al-4V discs were passivated, coated with SCPC50 (200 nm - 10 mum) and thermally treated at 600 - 800 ºC to produce a coating thickness in the range of 43.1 +/- 5.7 to 30.1 +/- 4.6 μm. After treatment at 600, 700 and 800 ºC, the adhesion strength at the SCPC50/Ti-6Al-4V interface was 42.6 +/- 3.6, 44.7 +/- 8.7 and 47.2 +/- 4.3 MPa, respectively. XRD analyses of SCPC50 before and after EPD coating indicated no change in the crystallinity of the material. Fracture surface analyses showed that failure occurred within the ceramic layer or at the ceramic/polymer interface; however, the ceramic/metal interface was intact in all samples. The adhesion strength of SCPC50-coated substrates after immersion in PBS for 2 days (11.7 +/- 3.9 MPa) was higher than that measured on commercially available hydroxyapatite (HA) coated substrates (5.5 +/- 2.7 MPa), although the

  19. Survey Finds Few Orthopedic Surgeons Know The Costs Of The Devices They Implant

    PubMed Central

    Okike, Kanu; O’Toole, Robert V.; Pollak, Andrew N.; Bishop, Julius A.; McAndrew, Christopher M.; Mehta, Samir; Cross, William W.; Garrigues, Grant E.; Harris, Mitchel B.; Lebrun, Christopher T.

    2014-01-01

    Orthopedic procedures represent a large expense to the Medicare program, and costs of implantable medical devices account for a large proportion of those procedures’ costs. Physicians have been encouraged to consider costs in the selection of devices, but several factors make acquiring information about costs difficult. To assess physicians’ levels of knowledge about costs, we asked orthopedic attending physicians and residents at seven academic medical centers to estimate the costs of thirteen commonly used orthopedic devices between December 2012 and March 2013. The actual cost of each device was determined at each institution; estimates within 20 percent of the actual cost were considered correct. Among the 503 physicians who completed our survey, attending physicians correctly estimated the cost of the device 21 percent of the time, and residents did so 17 percent of the time. Thirty-six percent of physicians and 75 percent of residents rated their knowledge of device costs “below average” or “poor.” However, more than 80 percent of all respondents indicated that cost should be “moderately,” “very,” or “extremely” important in the device selection process. Surgeons need increased access to information on the relative prices of devices and should be incentivized to participate in cost-containment efforts. PMID:24395941

  20. Clinical impact of positive Propionibacterium acnes cultures in orthopedic surgery.

    PubMed

    Lavergne, V; Malo, M; Gaudelli, C; Laprade, M; Leduc, S; Laflamme, P; Rouleau, D M

    2017-04-01

    The clinical significance of a positive culture to Propionibacterium acnes in orthopedic specimens remains unclear, whether about its role as a contaminant or a pathogen, or its impact as a coinfectant. Therefore, we performed a retrospective study to provide a more accurate description of the clinical impact of P. acnes in an orthopedic population aiming to determine: 1) if there is a clinical difference between P. acnes infection and contamination? 2) If there is a clinical difference between P. acnes monoinfection, and coinfection. There is a clinical difference between P. acnes infection and contamination. Patients were selected over a five-year period, and those with a minimum of one positive culture for P. acnes, from any intraoperative orthopedic tissue sample, were included in the study. P. acnes infection was defined as the isolation of P. acnes from≥2 specimens, or in only one specimen, in the presence of typical perioperative findings and/or local signs of infection. A total of 68 patients had a positive P. acnes culture, 35 of which were considered to be infected. The infections affected mostly males (29/35-83%), occurred mostly in shoulders (22/35-63%), and at a site already containing an orthopedic implant (32/35-91%). Local inflammatory signs were present in half of the cases when an infection was diagnosed. Coinfection with other pathogens was present in 31% of patients (11/35). When comparing patients coinfected with P. acnes, and those who were monoinfected, the latter presented less often with local inflammatory signs. Recurrence rate was 24% (8/35) and the only risk factor for recurrence was the presence of a monoinfection. This study confirms the pathogenicity of P. acnes in an orthopedic population, as it is present in multiple samples in the same patient, and because it is present in cultures from cases with clinical recurrence. Our study showed that monoinfections differ from coinfections mainly by their higher risk of recurrence

  1. Imaging bacteria and biofilms on hardware and periprosthetic tissue in orthopedic infections.

    PubMed

    Nistico, Laura; Hall-Stoodley, Luanne; Stoodley, Paul

    2014-01-01

    Infection is a major complication of total joint arthroplasty (TJA) surgery, and even though it is now as low as 1 % in some hospitals, the increasing number of primary surgeries translates to tens of thousands of revisions due to prosthetic joint infection (PJI). In many cases the only solution is revision surgery in which the hardware is removed. This process is extremely long and painful for patients and is a considerable financial burden for the health-care system. A significant proportion of the difficulties in diagnosis and treatment of PJI are associated with biofilm formation where bacteria attach to the surface of the prosthesis and periprosthetic tissue and build a 3-D biofilm community encased in an extracellular polymeric slime (EPS) matrix. Bacteria in biofilms have a low metabolic rate which is thought to be a major contributor to their recalcitrance to antibiotic treatment. The diagnosis of biofilm infections is difficult due to the fact that bacteria in biofilms are not readily cultured with standard clinical microbiology techniques. To identify and visualize in situ biofilm bacteria in orthopedic samples, we have developed protocols for the collection of samples in the operating room, for molecular fluorescent staining with 16S rRNA fluorescence in situ hybridization (FISH), and for imaging of samples using confocal laser scanning microscopy (CLSM). Direct imaging is the only method which can definitively identify biofilms on implants and complements both culture and culture-independent diagnostic methods.

  2. In vivo evaluation of the anti-infection potential of gentamicin-loaded nanotubes on titania implants

    PubMed Central

    Yang, Ying; Ao, Hai-yong; Yang, Sheng-bing; Wang, Yu-gang; Lin, Wen-tao; Yu, Zhi-feng; Tang, Ting-ting

    2016-01-01

    Titanium-based implants have been widely used in orthopedic surgery; however, failures still occur. Our in vitro study has demonstrated that gentamicin-loaded, 80 nm-diameter nanotubes possessed both antibacterial and osteogenic activities. Thus, the aim of this study was to further investigate the in vivo anti-infection effect of the titanium implants with gentamicin-loaded nanotubes. Thirty-six male Sprague Dawley rats were used to establish an implant-associated infection model. A volume of 50 μL Staphylococcus aureus suspension (1×105 CFU/mL) was injected into the medullary cavity of the left femur, and then the titanium rods without modification (Ti), titanium nanotubes without drug loading (NT), and gentamicin-loaded titanium nanotubes (NT-G) were inserted with phosphate-buffered saline-inoculated Ti rods as a blank control. X-ray images were obtained 1 day, 21 days, and 42 days after surgery; micro-computed tomography, microbiological, and histopathological analyses were used to evaluate the infections at the time of sacrifice. Radiographic signs of bone infection, including osteolysis, periosteal reaction, osteosclerosis, and damaged articular surfaces, were demonstrated in the infected Ti group and were slightly alleviated in the NT group but not observed in the NT-G group. Meanwhile, the radiographic and gross bone pathological scores of the NT-G group were significantly lower than those of the infected Ti group (P<0.01). Explant cultures revealed significantly less bacterial growth in the NT-G group than in the Ti and NT groups (P<0.01), and the NT group showed decreased live bacterial growth compared with the Ti group (P<0.01). Confocal laser scanning microscopy, scanning electron microscopy, and histopathological observations further confirmed decreased bacterial burden in the NT-G group compared with the Ti and NT groups. We concluded that the NT-G coatings can significantly prevent the development of implant-associated infections in a rat model

  3. Implant vendors and hospitals: competing influences over product choice by orthopedic surgeons.

    PubMed

    Burns, Lawton R; Housman, Michael G; Booth, Robert E; Koenig, Aaron

    2009-01-01

    Vendors of hip and knee implants court orthopedic surgeons to adopt their products. Hospitals, which have to pay for these products, now court the same surgeons to help reduce the number of vendors and contain implant costs. This study measures the surgeon's perceived alignment of interests with both vendors and hospitals and gauges surgeons' exposure and receptivity to hospital cost-containment efforts. We surveyed all practicing orthopedists performing 12 or more implant procedures annually in Pennsylvania. The survey identified the surgeon's preferred vendor, tenure with that vendor, use of the vendor during residency training, receipt of financial payments from the vendor, alignment of interests with both vendor and hospital stakeholders, and exposure and receptivity to hospital cost-containment efforts. Surgeons have long-standing relationships with implant vendors, but only a small proportion receive financial payments. Surgeons align most closely with the vendor's sales representative and least closely with the hospital's purchasing manager. Paradoxically, surgeons support hospital efforts to limit the number of vendors but report that their own choice of vendor is not constrained. The major drivers of surgeons' alignment and stance toward cost containment are their tenure with and receipt of financial payments from the vendor. Hospitals face a competitive disadvantage in capturing the attention of orthopedists, compared with implant vendors. The vendors' advantage stems from historical, financial, and service benefits offered to surgeons. Hospital executives now seek to offer comparable benefits to surgeons.

  4. Biodegradable Orthopedic Magnesium-Calcium (MgCa) Alloys, Processing, and Corrosion Performance.

    PubMed

    Salahshoor, Meisam; Guo, Yuebin

    2012-01-09

    Magnesium-Calcium (Mg-Ca) alloy has received considerable attention as an emerging biodegradable implant material in orthopedic fixation applications. The biodegradable Mg-Ca alloys avoid stress shielding and secondary surgery inherent with permanent metallic implant materials. They also provide sufficient mechanical strength in load carrying applications as opposed to biopolymers. However, the key issue facing a biodegradable Mg-Ca implant is the fast corrosion in the human body environment. The ability to adjust degradation rate of Mg-Ca alloys is critical for the successful development of biodegradable orthopedic implants. This paper focuses on the functions and requirements of bone implants and critical issues of current implant biomaterials. Microstructures and mechanical properties of Mg-Ca alloys, and the unique properties of novel magnesium-calcium implant materials have been reviewed. Various manufacturing techniques to process Mg-Ca based alloys have been analyzed regarding their impacts on implant performance. Corrosion performance of Mg-Ca alloys processed by different manufacturing techniques was compared. In addition, the societal and economical impacts of developing biodegradable orthopedic implants have been emphasized.

  5. Biodegradable Orthopedic Magnesium-Calcium (MgCa) Alloys, Processing, and Corrosion Performance

    PubMed Central

    Salahshoor, Meisam; Guo, Yuebin

    2012-01-01

    Magnesium-Calcium (Mg-Ca) alloy has received considerable attention as an emerging biodegradable implant material in orthopedic fixation applications. The biodegradable Mg-Ca alloys avoid stress shielding and secondary surgery inherent with permanent metallic implant materials. They also provide sufficient mechanical strength in load carrying applications as opposed to biopolymers. However, the key issue facing a biodegradable Mg-Ca implant is the fast corrosion in the human body environment. The ability to adjust degradation rate of Mg-Ca alloys is critical for the successful development of biodegradable orthopedic implants. This paper focuses on the functions and requirements of bone implants and critical issues of current implant biomaterials. Microstructures and mechanical properties of Mg-Ca alloys, and the unique properties of novel magnesium-calcium implant materials have been reviewed. Various manufacturing techniques to process Mg-Ca based alloys have been analyzed regarding their impacts on implant performance. Corrosion performance of Mg-Ca alloys processed by different manufacturing techniques was compared. In addition, the societal and economical impacts of developing biodegradable orthopedic implants have been emphasized. PMID:28817036

  6. Value of monoenergetic dual-energy CT (DECT) for artefact reduction from metallic orthopedic implants in post-mortem studies.

    PubMed

    Filograna, Laura; Magarelli, Nicola; Leone, Antonio; Guggenberger, Roman; Winklhofer, Sebastian; Thali, Michael John; Bonomo, Lorenzo

    2015-09-01

    The aim of this ex vivo study was to assess the performance of monoenergetic dual-energy CT (DECT) reconstructions to reduce metal artefacts in bodies with orthopedic devices in comparison with standard single-energy CT (SECT) examinations in forensic imaging. Forensic and clinical impacts of this study are also discussed. Thirty metallic implants in 20 consecutive cadavers with metallic implants underwent both SECT and DECT with a clinically suitable scanning protocol. Extrapolated monoenergetic DECT images at 64, 69, 88, 105, 120, and 130 keV and individually adjusted monoenergy for optimized image quality (OPTkeV) were generated. Image quality of the seven monoenergetic images and of the corresponding SECT image was assessed qualitatively and quantitatively by visual rating and measurements of attenuation changes induced by streak artefact. Qualitative and quantitative analyses showed statistically significant differences between monoenergetic DECT extrapolated images and SECT, with improvements in diagnostic assessment in monoenergetic DECT at higher monoenergies. The mean value of OPTkeV was 137.6 ± 4.9 with a range of 130 to 148 keV. This study demonstrates that monoenergetic DECT images extrapolated at high energy levels significantly reduce metallic artefacts from orthopedic implants and improve image quality compared to SECT examination in forensic imaging.

  7. 76 FR 20690 - International Consortium of Orthopedic Registries; Public Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... orthopedic implant information and create a research network to advance the methodology and conduct of research related to orthopedic device performance. Date and Time: The public workshop will be held on May 9... discussion among FDA and international orthopedic registries and develop a research consortium (ICOR) that...

  8. Allergic reaction to vanadium causes a diffuse eczematous eruption and titanium alloy orthopedic implant failure.

    PubMed

    Engelhart, Sally; Segal, Robert J

    2017-04-01

    Allergy as a cause of adverse outcomes in patients with implanted orthopedic hardware is controversial. Allergy to titanium-based implants has not been well researched, as titanium is traditionally thought to be inert. We highlight the case of a patient who developed systemic dermatitis and implant failure after surgical placement of a titanium alloy (Ti6Al4V) plate in the left foot. The hardware was removed and the eruption cleared in the following weeks. The plate and screws were submitted for metal analysis. The elemental composition of both the plate and screws included 3 major elements-titanium, aluminum, and vanadium-as well as trace elements. Metal analysis revealed that the plate and screws had different microstructures, and electrochemical studies demonstrated that galvanic corrosion could have occurred between the plate and screws due to their different microstructures, contributing to the release of vanadium in vivo. The patient was patch tested with several metals including components of the implant and had a positive patch test reaction only to vanadium trichloride. These findings support a diagnosis of vanadium allergy and suggests that clinicians should consider including vanadium when patch testing patients with a suspected allergic reaction to vanadium-containing implants.

  9. Pitavastatin attenuates monocyte activation in response to orthopedic implant-derived wear particles by suppressing the NF-κB signaling pathway.

    PubMed

    Zhang, Zehua; Dai, Fei; Cheng, Peng; Luo, Fei; Hou, Tianyong; Zhou, Qiang; Xie, Zhao; Deng, Moyuan; Xu, Jian-Zhong

    2015-11-01

    Aseptic loosening secondary to particle‑induced periprosthetic osteolysis is considered to be the primary cause of long‑term implant failure in orthopedic surgery. Implant‑derived wear particles activate and recruit macrophages and osteoclasts, which cause a persistent inflammatory response with bone destruction that is followed by a loosening of the implant. Thus, strategies for inhibiting macrophage and osteoclast function may provide a therapeutic benefit for preventing aseptic loosening. The aim of the present study was to determine the effects of pitavastatin on the activation and cytokine response of polymethyl methacrylate (PMMA) particle‑induced monocytes. Peripheral blood monocytes were obtained and treated with PMMA and pitavastatin. ELISA demonstrated that pitavastatin inhibited mRNA and protein expression of interleukin (IL)‑1β, IL‑6 and tumor necrosis factor‑α. Western blot analysis and immunofluorescence staining demonstrated that pitavastatin downregulated inhibitor of κB phosphorylation and degradation, and nuclear factor κ‑light‑chain‑enhancer of activated B cells (NF‑κB) p65 translocation. Together, these results indicate that pitavastatin may attenuate monocyte activation in response to orthopedic implant wear particles by suppression of the NF‑κB signaling pathway.

  10. Strategies for achieving orthopedic service line success.

    PubMed

    Lang, Stacey; Powers, Kristi

    2013-12-01

    Healthcare finance leaders can work with orthopedic surgeons to support better outcomes, clinically and financially, by: Establishing innovative partnerships among hospital leaders, orthopedic surgeons, and implant vendors. Developing and enforcing expectations around contracting and vendor behavior. Establishing a forum for open communication. Building a bundled payment structure. Finding ways to differentiate from the competition.

  11. Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces.

    PubMed

    Gilbert, Jeremy L; Sivan, Shiril; Liu, Yangping; Kocagöz, Sevi B; Arnholt, Christina M; Kurtz, Steven M

    2015-01-01

    Cobalt-chromium-molybdenum (CoCrMo) alloy, used for over five decades in orthopedic implants, may corrode and release wear debris into the body during use. These degradation products may stimulate immune and inflammatory responses in vivo. We report here on evidence of direct inflammatory cell-induced corrosion of human implanted and retrieved CoCrMo implant surfaces. Corrosion morphology on CoCrMo implant surfaces, in unique and characteristic patterns, and the presence of cellular remnants and biological materials intimately entwined with the corrosion indicates direct cellular attack under the cell membrane region of adhered and/or migrating inflammatory cells. Evidence supports a Fenton-like reaction mechanism driving corrosion in which reactive oxygen species are the major driver of corrosion. Using in vitro tests, large increases in corrosion susceptibility of CoCrMo were seen (40-100 fold) when immersed in phosphate buffered saline solutions modified with hydrogen peroxide and hydrochloric acid to represent the chemistry under inflammatory cells. This discovery raises significant new questions about the clinical consequences of such corrosion interactions, the role of patient inflammatory reactions, and the detailed mechanisms at play. © 2014 Wiley Periodicals, Inc.

  12. Direct In Vivo Inflammatory Cell-Induced Corrosion of CoCrMo Alloy Orthopedic Implant Surfaces

    PubMed Central

    Gilbert, Jeremy L.; Sivan, Shiril; Liu, Yangping; Kocagöz, Sevi; Arnholt, Christina; Kurtz, Steven M.

    2014-01-01

    Cobalt-chromium-molybdenum alloy, used for over four decades in orthopedic implants, may corrode and release wear debris into the body during use. These degradation products may stimulate immune and inflammatory responses in vivo. We report here on evidence of direct inflammatory cell-induced corrosion of human implanted and retrieved CoCrMo implant surfaces. Corrosion morphology on CoCrMo implant surfaces, in unique and characteristic patterns, and the presence of cellular remnants and biological materials intimately entwined with the corrosion indicates direct cellular attack under the cell membrane region of adhered and/or migrating inflammatory cells. Evidence supports a Fenton-like reaction mechanism driving corrosion in which reactive oxygen species are the major driver of corrosion. Using in vitro tests, large increases in corrosion susceptibility of CoCrMo were seen (40 to 100 fold) when immersed in phosphate buffered saline solutions modified with hydrogen peroxide and HCl to represent the chemistry under inflammatory cells. This discovery raises significant new questions about the clinical consequences of such corrosion interactions, the role of patient inflammatory reactions, and the detailed mechanisms at play. PMID:24619511

  13. Ion beam sputter etching of orthopedic implanted alloy MP35N and resulting effects on fatigue

    NASA Technical Reports Server (NTRS)

    Wintucky, E. G.; Christopher, M.; Bahnuik, E.; Wang, S.

    1981-01-01

    The effects of two types of argon ion sputter etched surface structures on the tensile stress fatigue properties of orthopedic implant alloy MP35N were investigated. One surface structure was a natural texture resulting from direct bombardment by 1 keV argon ions. The other structure was a pattern of square holes milled into the surface by a 1 keV argon ion beam through a Ni screen mask. The etched surfaces were subjected to tensile stress only in fatigue tests designed to simulate the cyclic load conditions experienced by the stems of artificial hip joint implants. Both types of sputter etched surface structures were found to reduce the fatigue strength below that of smooth surface MP35N.

  14. A novel co-culture model of murine K12 osteosarcoma cells and S. aureus on common orthopedic implant materials: 'the race to the surface' studied in vitro.

    PubMed

    McConda, David B; Karnes, Jonathan M; Hamza, Therwa; Lindsey, Brock A

    2016-07-01

    Infection is a major cause of orthopedic implant failure. There are few studies assessing both tissue cell and bacterial adherence on common orthopedic implant materials in a co-culture environment. An in vitro co-culture model was created using K12 osteosarcoma cells and Staphylococcus aureus in a medium incubated over metal disks for 48 h. The results showed that, in the presence of S. aureus, there were fewer osteosarcoma cells attached to the disks for all substrata tested. There were significantly more osteosarcoma cells adhering to the cobalt chrome than the stainless steel and titanium disks. Overall, in the presence of osteosarcoma cells, there were more bacteria adhering to the disks for all the substrata tested, with significantly more bacteria adhering to the stainless steel disks compared to cobalt chrome and titanium disks. Scanning electron microscopy verified that osteosarcoma cells and bacteria were adherent to the metal disks after incubation for 48 h. Furthermore, the observation that more bacteria were in the co-culture than in the control sample suggests that the osteosarcoma cells serve as a nutrient source for the bacteria. Future models assessing the interaction of osteogenic cells with bacteria on a substratum would be improved if the model accounted for the role of the immune system in secondary bone healing.

  15. Prevention and management of cochlear implant infections.

    PubMed

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  16. Daptomycin: local application in implant-associated infection and complicated osteomyelitis.

    PubMed

    Rosslenbroich, Steffen B; Raschke, Michael J; Kreis, Carolin; Tholema-Hans, Nancy; Uekoetter, Andreas; Reichelt, Rudolf; Fuchs, Thomas F

    2012-01-01

    The rise of highly resistant bacteria creates a persistent urge to develop new antimicrobial agents. This paper investigates the application of the lipopeptide antibiotic daptomycin in infections involving the human bone. Compressive and tensile strength testing of daptomycin-laden PMMA was performed referring to the ISO 5833. The microstructure of the antibiotic-laden PMMA was evaluated by scanning electron microscopy. Intracellular activity of daptomycin was determined by a human osteoblast infection model. Elution kinetics of the antibiotic-laden bone cement was measured by using a continuous flow chamber setup. There was no significant negative effect of adding 1.225% and 7.5% per weight of daptomycin to the PMMA. There was no significant difference in intracellular activity comparing gentamicin to daptomycin. Elution of daptomycin from PMMA showed within the first-hour initial peak values of 15-20 μg/mL. Daptomycin has a certain degree of activity in the intracellular environment of osteoblasts. Daptomycin admixed to PMMA remains bactericidal and does not significantly impair structural characteristics of the PMMA. The results of this paper suggest that daptomycin might be a potent alternative for treating osteomyelitis and implant-associated infection in trauma and orthopedic surgery caused by multiresistant strains.

  17. [The significance of biofilm for the treatment of infections in orthopedic surgery : 2017 Update].

    PubMed

    Scheuermann-Poley, C; Wagner, C; Hoffmann, J; Moter, A; Willy, C

    2017-06-01

    The increase in endoprosthetic and osteosynthetic surgical treatment is associated with a simultaneous increase in implant-associated infections (surgical site infections, SSI). Biofilms appear to play a significant role in the diagnosis and treatment of these infections and heavily contaminated wounds. This article aims to provide a current overview of biofilm and its relevance in orthopedic surgery. A computer-assisted literature search of MedLine (PubMed) was performed using key word combinations with "biofilm" (as of March 2017). Biofilm, a polymicrobial organization and life form surrounded by a polysaccharide matrix, refers to an adaptation strategy of bacteria in unfavorable living conditions (e. g. under antibiotic therapy). Biofilms can develop after 6 h in highly contaminated wounds. In acute and chronic infections, biofilms can occur in 30-80 % of the cases. Only planktonic bacteria (high metabolic activity, cultivable) can be detected in standard microbiological cultures, biofilms, however, cannot. Molecular microscopic methods, such as fluorescence in situ hybridization (FISH), enable the detection of bacteria in biofilms. The core concepts of anti-biofilm therapy include the prevention of biofilm and early surgical debridement, followed by the local and/or systemic administration of antibiotics as well as the local application of antiseptics. The development of biofilm should be anticipated in strongly contaminated wounds as well as in acute and chronic infection sites. The best strategy to combat biofilms is to prevent their development. Standard microbiological culture methods do not enable the detection of biofilm. Therefore, the implementation of molecular biological detection methods (z. B. FISH) is important. Further anti-biofilm strategies are being investigated experimentally, but there are no real options for clinical use as of yet.

  18. Administration of antibiotic agents before intraoperative sampling in orthopedic infections alters culture results.

    PubMed

    Al-Mayahi, Mohamed; Cian, Anais; Lipsky, Benjamin A; Suvà, Domizio; Müller, Camillo; Landelle, Caroline; Miozzari, Hermès H; Uçkay, Ilker

    2015-11-01

    Many physicians and surgeons think that prescribing antibiotics before intraoperative sampling does not alter the microbiological results. Case-control study of adult patients hospitalized with orthopedic infections. Among 2740 episodes of orthopedic infections, 1167 (43%) had received antibiotic therapy before surgical sampling. Among these, 220 (19%) grew no pathogens while the proportion of culture-negative results in the 2573 who had no preoperative antibiotic therapy was only 6%. By multivariate analyses, pre-operative antibiotic exposure was associated with significantly more culture-negative results (odds ratio 2.8, 95% confidence interval 2.1-3.7), more non-fermenting rods and skin commensals (odds ratio 2.8 and 3.0, respectively). Even a single pre-operative dose of antibiotic was significantly associated with subsequent culture-negative results (19/93 vs. 297/2350; χ²-test, p = 0.01) and skin commensals (17/74 vs. 274/2350; p = 0.01) compared to episodes without preceding prophylaxis. Prior antibiotic use, including single-dose prophylactic administrations, is three-fold associated with culture-negative results, non-fermenting rods and resistant skin commensals. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  19. Three-dimensional printing and nanotechnology for enhanced implantable materials

    NASA Astrophysics Data System (ADS)

    Tappa, Karthik Kumar

    Orthopedic and oro-maxillofacial implants have revolutionized treatment of bone diseases and fractures. Currently available metallic implants have been in clinical use for more than 40 years and have proved medically efficacious. However, several drawbacks remain, such as excessive stiffness, accumulation of metal ions in surrounding tissue, growth restriction, required removal/revision surgery, inability to carry drugs, and susceptibility to infection. The need for additional revision surgery increases financial costs and prolongs recovery time for patients. These metallic implants are bulk manufactured and often do not meet patient's requirements. A surgeon must machine (cut, weld, trim or drill holes) them in order to best suit the patient specifications. Over the past few decades, attempts have been made to replace these metallic implants with suitable biodegradable materials to prevent secondary/revision surgery. Recent advances in biomaterials have shown multiple uses for lactic acid polymers in bone implant technology. However, a targeted/localized drug delivery system needs to be incorporated in these polymers, and they need to be customized to treat orthopedic implant-related infections and other bone diseases such as osteomyelitis, osteosarcoma and osteoporosis. Rapid Prototyping (RP) using additive manufacturing (AM) or 3D printing could allow customization of constructs for personalized medicine. The goal of this study was to engineer customizable and biodegradable implant materials that can elute bioactive compounds for personalized medicine and targeted drug delivery. Post-operative infections are the most common complications following dental, orthopedic and bone implant surgeries. Preventing post-surgical infections is therefore a critical need that current polymethylmethacrylate (PMMA) bone cements fail to address. Calcium Phosphate Cements (CPCs) are unique in their ability to crystallize calcium and phosphate salts into hydroxyapatite (HA) and

  20. Infection rates of rifampin/gentamicin-coated Titan Coloplast penile implants. Comparison with Inhibizone-impregnated AMS penile implants.

    PubMed

    Dhabuwala, Chirpriya; Sheth, Sheila; Zamzow, Brent

    2011-01-01

    It is a common practice to soak Titan(®) Coloplast penile implants in antibiotic solution prior to implantation. Experience with Inhibizone impregnation suggests that rifampin coating significantly reduces infection rates of penile implant surgery. In this article we describe the results of coating Titan Coloplast penile implants with rifampin/gentamicin solution. To compare infection rates of Titan(®) Coloplast penile implants coated with vancomycin/gentamycin, rifampin/gentamicin, and Inhibizone-impregnated American Medical Systems (AMS) penile implants. Chart review was done for all Mentor/Coloplast and AMS implant surgeries performed at our center between the dates January 1, 2002 and February 8, 2010. Infection rates for Titan(®) Coloplast penile implants coated with vancomycin/gentamycin, rifampin/gentamicin, and Inhibizone-impregnated (AMS) penile implants were compared. Infection rates for penile implants coated with different antibiotics. Infection rates for Titan(®) Coloplast penile implants coated with vancomycin/gentamycin and Inhibizone-impregnated (AMS) penile implants was 4.4% and 1.3%, respectively (P = 0.05). None of the rifampin/gentamicin-coated Titan(®) Coloplast penile implants have developed infection. Rifampin is the common antibiotic both in rifampin/gentamicin-coated Coloplast implants and Inhibizone(®) . The infection rate in this combined rifampin/gentamicin-coated Titan Coloplast implants and Inhibizone-coated AMS implants group was 0.63% (P = 0.03). Both rifampin/gentamicin-coated Titan(®) Coloplast penile implants and Inhibizone-impregnated (AMS) penile implants appear to have lower infection rates compared with vancomycin/gentamycin-coated Titan(®) Coloplast penile implants The present study does not suggest superiority of rifampin/gentamicin-coated Titan(®) Coloplast penile implants or Inhibizone-impregnated (AMS) penile implants but we strongly suggest that all Titan(®) Coloplast penile implants should be coated with

  1. Optimal culture incubation time in orthopedic device-associated infections: a retrospective analysis of prolonged 14-day incubation.

    PubMed

    Schwotzer, Nora; Wahl, Peter; Fracheboud, Dominique; Gautier, Emanuel; Chuard, Christian

    2014-01-01

    Accurate diagnosis of orthopedic device-associated infections can be challenging. Culture of tissue biopsy specimens is often considered the gold standard; however, there is currently no consensus on the ideal incubation time for specimens. The aim of our study was to assess the yield of a 14-day incubation protocol for tissue biopsy specimens from revision surgery (joint replacements and internal fixation devices) in a general orthopedic and trauma surgery setting. Medical records were reviewed retrospectively in order to identify cases of infection according to predefined diagnostic criteria. From August 2009 to March 2012, 499 tissue biopsy specimens were sampled from 117 cases. In 70 cases (59.8%), at least one sample showed microbiological growth. Among them, 58 cases (82.9%) were considered infections and 12 cases (17.1%) were classified as contaminations. The median time to positivity in the cases of infection was 1 day (range, 1 to 10 days), compared to 6 days (range, 1 to 11 days) in the cases of contamination (P < 0.001). Fifty-six (96.6%) of the infection cases were diagnosed within 7 days of incubation. In conclusion, the results of our study show that the incubation of tissue biopsy specimens beyond 7 days is not productive in a general orthopedic and trauma surgery setting. Prolonged 14-day incubation might be of interest in particular situations, however, in which the prevalence of slow-growing microorganisms and anaerobes is higher.

  2. Bisphosphonate-Based Strategies for Bone Tissue Engineering and Orthopedic Implants

    PubMed Central

    Cattalini, Juan Pablo; Boccaccini, Aldo R.; Lucangioli, Silvia

    2012-01-01

    Bisphosphonates (BPs) are a group of well-established drugs that are applied in the development of metabolic bone disorder-related therapies. There is increasing interest also in the application of BPs in the context of bone tissue engineering, which is the topic of this review, in which an extensive overview of published studies on the development and applications of BPs-based strategies for bone regeneration is provided with special focus on the rationale for the use of different BPs in three-dimensional (3D) bone tissue scaffolds. The different alternatives that are investigated to address the delivery and sustained release of these therapeutic drugs in the nearby tissues are comprehensively discussed, and the most significant published approaches on bisphosphonate-conjugated drugs in multifunctional 3D scaffolds as well as the role of BPs within coatings for the improved fixation of orthopedic implants are presented and critically evaluated. Finally, the authors' views regarding the remaining challenges in the fields and directions for future research efforts are highlighted. PMID:22440082

  3. Propionibacterium acnes, an emerging pathogen: from acne to implant-infections, from phylotype to resistance.

    PubMed

    Aubin, G G; Portillo, M E; Trampuz, A; Corvec, S

    2014-06-01

    Propionibacterium acnes colonizes the lipid-rich sebaceous glands of the skin. This preferential anaerobic bacterium is easily identified if cultures are prolonged. It is involved in the inflammation process of acne, but until recently, it was neglected in other clinical presentations. Despite a reported low virulence, the new genomic, transcriptomic, and phylogenetic studies have allowed better understanding of this pathogen's importance that causes many chronic and recurrent infections, including orthopedic and cardiac prosthetic, and breast or eye implant-infections. These infections, facilitated by the ability of P. acnes to produce a biofilm, require using anti-biofilm active antibiotics such as rifampicin. The antibiogram of P. acnes is not systematically performed in microbiology laboratories because of its susceptibility to a wide range of antibiotics. However, in the last 10 years, the rate of antibiotic-resistant bacteria has increased, especially for macrolides and tetracyclines. Recently, rpoB gene mutations conferring resistance to rifampicin have been also reported. Thus in case of a biofilm growth mode, the therapeutic strategy should be discussed, according to the resistance phylotype and phenotype so as to optimize the treatment of these severe infections. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  4. Use of antibiotic beads to salvage infected breast implants.

    PubMed

    Sherif, Rami D; Ingargiola, Michael; Sanati-Mehrizy, Paymon; Torina, Philip J; Harmaty, Marco A

    2017-10-01

    When an implant becomes infected, implant salvage is often performed where the implant is removed, capsulectomy is performed, and a new implant is inserted. The patient is discharged with a PICC line and 6-8 weeks of intravenous (IV) antibiotics. This method has variable success and subjects the patient to long-term systemic antibiotics. In the 1960s, the use of antibiotic-impregnated beads for the treatment of chronic osteomyelitis was described. These beads deliver antibiotic directly to the site of the infection, thereby eliminating the complications of systemic IV antibiotics. This study aimed to present a case series illustrating the use of STIMULAN calcium sulfate beads loaded with vancomycin and tobramycin to increase the rate of salvage of the infected implant and forgo IV antibiotics. A retrospective analysis was performed of patients who were treated at Mount Sinai Hospital for implant infection with salvage and antibiotic beads. Twelve patients were identified, 10 of whom had breast cancer. Comorbidities included hypertension, smoking, and immunocompromised status. Infections were noted anywhere from 5 days to 8 years postoperatively. Salvage was successful in 9 out of the 12 infected implants using antibiotic bead therapy without home IV antibiotics. The use of antibiotic beads is promising for salvaging infected breast implants without IV antibiotics. Seventy-five percent of the implants were successfully salvaged. Of the three patients who had unsalvageable implants, one was infected with antibiotic-resistant Rhodococcus that was refractory to bead therapy and one was noncompliant with postoperative instructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Implant healing in experimental animal models of diabetes.

    PubMed

    Le, Nga N; Rose, Michael B; Levinson, Howard; Klitzman, Bruce

    2011-05-01

    Diabetes mellitus is becoming increasingly prevalent worldwide. Additionally, there is an increasing number of patients receiving implantable devices such as glucose sensors and orthopedic implants. Thus, it is likely that the number of diabetic patients receiving these devices will also increase. Even though implantable medical devices are considered biocompatible by the Food and Drug Administration, the adverse tissue healing that occurs adjacent to these foreign objects is a leading cause of their failure. This foreign body response leads to fibrosis, encapsulation of the device, and a reduction or cessation of device performance. A second adverse event is microbial infection of implanted devices, which can lead to persistent local and systemic infections and also exacerbates the fibrotic response. Nearly half of all nosocomial infections are associated with the presence of an indwelling medical device. Events associated with both the foreign body response and implant infection can necessitate device removal and may lead to amputation, which is associated with significant morbidity and cost. Diabetes mellitus is generally indicated as a risk factor for the infection of a variety of implants such as prosthetic joints, pacemakers, implantable cardioverter defibrillators, penile implants, and urinary catheters. Implant infection rates in diabetic patients vary depending upon the implant and the microorganism, however, for example, diabetes was found to be a significant variable associated with a nearly 7.2% infection rate for implantable cardioverter defibrillators by the microorganism Candida albicans. While research has elucidated many of the altered mechanisms of diabetic cutaneous wound healing, the internal healing adjacent to indwelling medical devices in a diabetic model has rarely been studied. Understanding this healing process is crucial to facilitating improved device design. The purpose of this article is to summarize the physiologic factors that

  6. Implant Healing in Experimental Animal Models of Diabetes

    PubMed Central

    Le, Nga N; Rose, Michael B; Levinson, Howard; Klitzman, Bruce

    2011-01-01

    Diabetes mellitus is becoming increasingly prevalent worldwide. Additionally, there is an increasing number of patients receiving implantable devices such as glucose sensors and orthopedic implants. Thus, it is likely that the number of diabetic patients receiving these devices will also increase. Even though implantable medical devices are considered biocompatible by the Food and Drug Administration, the adverse tissue healing that occurs adjacent to these foreign objects is a leading cause of their failure. This foreign body response leads to fibrosis, encapsulation of the device, and a reduction or cessation of device performance. A second adverse event is microbial infection of implanted devices, which can lead to persistent local and systemic infections and also exacerbates the fibrotic response. Nearly half of all nosocomial infections are associated with the presence of an indwelling medical device. Events associated with both the foreign body response and implant infection can necessitate device removal and may lead to amputation, which is associated with significant morbidity and cost. Diabetes mellitus is generally indicated as a risk factor for the infection of a variety of implants such as prosthetic joints, pacemakers, implantable cardioverter defibrillators, penile implants, and urinary catheters. Implant infection rates in diabetic patients vary depending upon the implant and the microorganism, however, for example, diabetes was found to be a significant variable associated with a nearly 7.2% infection rate for implantable cardioverter defibrillators by the microorganism Candida albicans. While research has elucidated many of the altered mechanisms of diabetic cutaneous wound healing, the internal healing adjacent to indwelling medical devices in a diabetic model has rarely been studied. Understanding this healing process is crucial to facilitating improved device design. The purpose of this article is to summarize the physiologic factors that

  7. Continuation of TNF blockade in patients with inflammatory rheumatic disease. An observational study on surgical site infections in 1,596 elective orthopedic and hand surgery procedures.

    PubMed

    Berthold, Elisabet; Geborek, Pierre; Gülfe, Anders

    2013-10-01

    Increased infection risk in inflammatory rheumatic diseases may be due to inflammation or immunosuppressive treatment. The influence of tumor necrosis factor (TNF) inhibitors on the risk of developing surgical site infections (SSIs) is not fully known. We compared the incidence of SSI after elective orthopedic surgery or hand surgery in patients with a rheumatic disease when TNF inhibitors were continued or discontinued perioperatively. We included 1,551 patients admitted for elective orthopedic surgery or hand surgery between January 1, 2003 and September 30, 2009. Patient demographic data, previous and current treatment, and factors related to disease severity were collected. Surgical procedures were grouped as hand surgery, foot surgery, implant-related surgery, and other surgery. Infections were recorded and defined according to the 1992 Centers for Disease Control definitions for SSI. In 2003-2005, TNF inhibitors were discontinued perioperatively (group A) but not during 2006-2009 (group B). In group A, there were 28 cases of infection in 870 procedures (3.2%) and in group B, there were 35 infections in 681 procedures (5.1%) (p = < 0.05). Only foot surgery had significantly more SSIs in group B, with very low rates in group A. In multivariable analysis with groups A and B merged, only age was predictive of SSI in a statistically significant manner. Overall, the SSI rates were higher after abolishing the discontinuation of anti-TNF perioperatively, possibly due to unusually low rates in the comparator group. None of the medical treatments analyzed, e.g. methotrexate or TNF inhibitors, were significant risk factors for SSI. Continuation of TNF blockade perioperatively remains a routine at our center.

  8. High-strength, surface-porous polyether-ether-ketone for load-bearing orthopedic implants.

    PubMed

    Evans, Nathan T; Torstrick, F Brennan; Lee, Christopher S D; Dupont, Kenneth M; Safranski, David L; Chang, W Allen; Macedo, Annie E; Lin, Angela S P; Boothby, Jennifer M; Whittingslow, Daniel C; Carson, Robert A; Guldberg, Robert E; Gall, Ken

    2015-02-01

    Despite its widespread clinical use in load-bearing orthopedic implants, polyether-ether-ketone (PEEK) is often associated with poor osseointegration. In this study, a surface-porous PEEK material (PEEK-SP) was created using a melt extrusion technique. The porous layer was 399.6±63.3 μm thick and possessed a mean pore size of 279.9±31.6 μm, strut spacing of 186.8±55.5 μm, porosity of 67.3±3.1% and interconnectivity of 99.9±0.1%. Monotonic tensile tests showed that PEEK-SP preserved 73.9% of the strength (71.06±2.17 MPa) and 73.4% of the elastic modulus (2.45±0.31 GPa) of as-received, injection-molded PEEK. PEEK-SP further demonstrated a fatigue strength of 60.0 MPa at one million cycles, preserving 73.4% of the fatigue resistance of injection-molded PEEK. Interfacial shear testing showed the pore layer shear strength to be 23.96±2.26 MPa. An osseointegration model in the rat revealed substantial bone formation within the pore layer at 6 and 12 weeks via microcomputed tomography and histological evaluation. Ingrown bone was more closely apposed to the pore wall and fibrous tissue growth was reduced in PEEK-SP when compared to non-porous PEEK controls. These results indicate that PEEK-SP could provide improved osseointegration while maintaining the structural integrity necessary for load-bearing orthopedic applications. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. Advances in the local and targeted delivery of anti-infective agents for management of osteomyelitis.

    PubMed

    Ford, Caleb A; Cassat, James E

    2017-09-01

    Osteomyelitis, a common and debilitating invasive infection of bone, is a frequent complication following orthopedic surgery and causes pathologic destruction of skeletal tissues. Bone destruction during osteomyelitis results in necrotic tissue, which is poorly penetrated by antibiotics and can serve as a nidus for relapsing infection. Osteomyelitis therefore frequently necessitates surgical debridement procedures, which provide a unique opportunity for targeted delivery of antimicrobial and adjunctive therapies. Areas covered: Following surgical debridement, tissue voids require implanted materials to facilitate the healing process. Antibiotic-loaded, non-biodegradable implants have been the standard of care. However, a new generation of biodegradable, osteoconductive materials are being developed. Additionally, in the face of widespread antimicrobial resistance, alternative therapies to traditional antibiotic regimens are being investigated, including bone targeting compounds, antimicrobial surface modifications of orthopedic implants, and anti-virulence strategies. Expert commentary: Recent advances in biodegradable drug delivery scaffolds make this technology an attractive alternative to traditional techniques for orthopedic infection that require secondary operations for removal. Advances in novel treatment methods are expanding the arsenal of viable antimicrobial treatment strategies in the face of widespread drug resistance. Despite a need for large scale clinical investigations, these strategies offer hope for future treatment of this difficult invasive disease.

  10. Advances in the Local and Targeted Delivery of Anti-infective Agents for Management of Osteomyelitis

    PubMed Central

    Ford, Caleb A.; Cassat, James E.

    2018-01-01

    Structured Abstract Introduction Osteomyelitis, a common and debilitating invasive infection of bone, is a frequent complication following orthopedic surgery and causes pathologic destruction of skeletal tissues. Bone destruction during osteomyelitis results in necrotic tissue, which is poorly penetrated by antibiotics and can serve as a nidus for relapsing infection. Osteomyelitis therefore frequently necessitates surgical debridement procedures, which provide a unique opportunity for targeted delivery of antimicrobial and adjunctive therapies. Areas Covered Following surgical debridement, tissue voids require implanted materials to facilitate the healing process. Antibiotic-loaded, non-biodegradable implants have been the standard of care. However, a new generation of biodegradable, osteoconductive materials are being developed. Additionally, in the face of widespread antimicrobial resistance, alternative therapies to traditional antibiotic regimens are being investigated, including bone targeting compounds, antimicrobial surface modifications of orthopedic implants, and anti-virulence strategies. Expert Commentary Recent advances in biodegradable drug delivery scaffolds make this technology an attractive alternative to traditional techniques for orthopedic infection that require secondary operations for removal. Advances in novel treatment methods are expanding the arsenal of viable antimicrobial treatment strategies in the face of widespread drug resistance. Despite a need for large scale clinical investigations, these strategies offer hope for future treatment of this difficult invasive disease. PMID:28837368

  11. Complete removal of infected devices and simultaneous implantation of new devices for infective endocarditis after pacemaker implantation.

    PubMed

    Miura, Takuya; Inoue, Kazushige; Yokota, Takenori; Iwata, Takashi; Yoshitatsu, Masao

    2017-02-01

    Two cases of infective endocarditis after pacemaker implantation were reported. Complete removal of infected devices was performed under cardiopulmonary bypass, and simultaneous implantation of new devices was performed using epicardial leads and generator on the abdominal wall. The postoperative course was uneventful and recurrence was not recognized. These procedures may be suitable for the patients who depend on the pacemaker or who have repeat bacteremia with other infectious disease or conditions.

  12. Selective laser sintering of calcium phosphate materials for orthopedic implants

    NASA Astrophysics Data System (ADS)

    Lee, Goonhee

    control of micro and macro pore structure, to maximize bone healing and provide sufficient mechanical strength. It also permits the complete removal of the polymeric binders that are resided in the SLS process. In collaboration with the University of Texas Health Science Center at San Antonio and BioMedical Enterprises, Inc., porous implants based on anatomical geometry have been successfully implanted in rabbits and dogs. These histologic animal studies reveal excellent biocompatibility and show its great potential for commercial custom-fit implant manufacture. The second research effort involves fabrication of fully dense bone for application in dental restoration and load-bearing orthopedic functions. Calcium phosphate glass melts, proven to be biocompatible in the first effort, were cast into carbon molds. Processes were developed for preparing the molds. These carbon molds of anatomic shape can be prepared from either Computer Numerical Control (CNC) milling of slab stock or SLS processing of thermoset-coated graphite powder. The CNC milling method provides accurate dimension of the molds in a short period of time, however, the capable geometries are limited; generally two pieces of molds are required for complex shapes. The SLS method provides very complex shape green molds. However, they need to go through pyrolysis of thermoset binder to provide the high temperature capability reached at calcium phosphate melt temperatures (1100°C) and noticeable shrinkage was observed during pyrolysis. The cast glass was annealed to develop polycrystalline calcium phosphate. This process also exhibits great potential.

  13. Chemoprophylaxis in cardiac and orthopedic surgery: comparison of cephalothin and cephapirin.

    PubMed

    Bryant, R E; Hartstein, A I; Starr, A; Beals, R K

    1982-09-01

    In a retrospective sequential study we determined the rate of infection occurring despite cephalothin or cephapirin chemoprophylaxis in orthopedic and cardiac surgery done from 1973 to 1977. The incidence of infection after prosthetic hip placement or open reduction of hip fracture was 3.4% and 1.0% in patients receiving cephalothin or cephapirin, respectively. The infection rate after prosthetic heart valve implantation was 3.5% in those receiving cephalothin and 1.6% in those receiving cephapirin. There was no significant difference in infection rate, duration of fever greater than or equal to 38.0 C, or length of postoperative hospitalization. The efficacy of selected antistaphylococcal antibiotics in preventing colonization of human fibrin clots by staphylococci was studied. Although cephapirin was effective at lower concentration, the activity of cephalothin and cephapirin was comparable. Cephalothin and cephapirin have equivalent chemoprophylactic activity by clinical and microbiological criteria, permitting cost to be used as a basis for choosing between these antibiotics.

  14. Metal artifact reduction in CT, a phantom study: subjective and objective evaluation of four commercial metal artifact reduction algorithms when used on three different orthopedic metal implants.

    PubMed

    Bolstad, Kirsten; Flatabø, Silje; Aadnevik, Daniel; Dalehaug, Ingvild; Vetti, Nils

    2018-01-01

    Background Metal implants may introduce severe artifacts in computed tomography (CT) images. Over the last few years dedicated algorithms have been developed in order to reduce metal artifacts in CT images. Purpose To investigate and compare metal artifact reduction algorithms (MARs) from four different CT vendors when imaging three different orthopedic metal implants. Material and Methods Three clinical metal implants were attached to the leg of an anthropomorphic phantom: cobalt-chrome; stainless steel; and titanium. Four commercial MARs were investigated: SmartMAR (GE); O-MAR (Philips); iMAR (Siemens); and SEMAR (Toshiba). The images were evaluated subjectively by three observers and analyzed objectively by calculating the fraction of pixels with CT number above 500 HU in a region of interest around the metal. The average CT number and image noise were also measured. Results Both subjective evaluation and objective analysis showed that MARs reduced metal artifacts and improved the image quality for CT images containing metal implants of steel and cobalt-chrome. When using MARs on titanium, all MARs introduced new visible artifacts. Conclusion The effect of MARs varied between CT vendors and different metal implants used in orthopedic surgery. Both in subjective evaluation and objective analysis the effect of applying MARs was most obvious on steel and cobalt-chrome implants when using SEMAR from Toshiba followed by SmartMAR from GE. However, MARs may also introduce new image artifacts especially when used on titanium implants. Therefore, it is important to reconstruct all CT images containing metal with and without MARs.

  15. Understanding long-term silver release from surface modified porous titanium implants.

    PubMed

    Shivaram, Anish; Bose, Susmita; Bandyopadhyay, Amit

    2017-08-01

    Prevention of orthopedic device related infection (ODRI) using antibiotics has met with limited amount of success and is still a big concern during post-surgery. As an alternative, use of silver as an antibiotic treatment to prevent surgical infections is being used due to the well-established antimicrobial properties of silver. However, in most cases silver is used in particulate form with wound dressings or with short-term devices such as catheters but not with load-bearing implants. We hypothesize that strongly adherent silver to load-bearing implants can offer longer term solution to infection in vivo. Keeping that in mind, the focus of this study was to understand the long term release study of silver ions for a period of minimum 6months from silver coated surface modified porous titanium implants. Implants were fabricated using a LENS™ system, a powder based additive manufacturing technique, with at least 25% volume porosity, with and without TiO 2 nanotubes in phosphate buffer saline (pH 7.4) to see if the total release of silver ions is within the toxic limit for human cells. Considering the fact that infection sites may reduce the local pH, silver release was also studied in acetate buffer (pH 5.0) for a period of 4weeks. Along with that, the osseointegrative properties as well as cytotoxicity of porous titanium implants were assessed in vivo for a period of 12weeks using a rat distal femur model. In vivo results indicate that porous titanium implants with silver coating show comparable, if not better, biocompatibility and bonding at the bone-implant interface negating any concerns related to toxicity related to silver to normal cells. The current research is based on our recently patented technology, however focused on understanding longer-term silver release to mitigate infection related problems in load-bearing implants that can even arise several months after the surgery. Prevention of orthopedic device related infection using antibiotics has met

  16. Three-Dimensional Printing in Orthopedic Surgery.

    PubMed

    Eltorai, Adam E M; Nguyen, Eric; Daniels, Alan H

    2015-11-01

    Three-dimensional (3D) printing is emerging as a clinically promising technology for rapid prototyping of surgically implantable products. With this commercially available technology, computed tomography or magnetic resonance images can be used to create graspable objects from 3D reconstructed images. Models can enhance patients' understanding of their pathology and surgeon preoperative planning. Customized implants and casts can be made to match an individual's anatomy. This review outlines 3D printing, its current applications in orthopedics, and promising future directions. Copyright 2015, SLACK Incorporated.

  17. pH dependent silver nanoparticles releasing titanium implant: A novel therapeutic approach to control peri-implant infection.

    PubMed

    Dong, Yiwen; Ye, Hui; Liu, Yi; Xu, Lihua; Wu, Zuosu; Hu, Xiaohui; Ma, Jianfeng; Pathak, Janak L; Liu, Jinsong; Wu, Gang

    2017-10-01

    Peri-implant infection control is crucial for implant fixation and durability. Antimicrobial administration approaches to control peri-implant infection are far from satisfactory. During bacterial infection, pH level around the peri-implant surface decreases as low as pH 5.5. This change of pH can be used as a switch to control antimicrobial drug release from the implant surface. Silver nanoparticles (AgNPs) have broad-spectrum antimicrobial properties. In this study, we aimed to design a pH-dependent AgNPs releasing titania nanotube arrays (TNT) implant for peri-implant infection control. The nanotube arrays were fabricated on the surface of titanium implant as containers; AgNPs were grafted on TNT implant surface via a low pH-sensitive acetal linker (TNT-AL-AgNPs). SEM, TEM, AFM, FTIR as well as XPS data showed that AgNPs have been successfully linked to TNT via acetal linker without affecting the physicochemical characteristics of TNT. The pH 5.5 enhanced AgNPs release from TNT-AL-AgNPs implant compared with pH 7.4. AgNPs released at pH 5.5 robustly increased antimicrobial activities against gram-positive and gram-negative bacteria compared with AgNPs released at pH 7.4. TNT-AL-AgNPs implant enhanced osteoblast proliferation, differentiation, and did not affect osteoblast morphology in vitro. In conclusion, incorporation of AgNPs in TNT via acetal linker maintained the surface characteristics of TNT. TNT-AL-AgNPs implant was biocompatible to osteoblasts and showed osteoinductive properties. AgNPs were released from TNT-AL-AgNPs implant in high dose at pH 5.5, and this release showed strong antimicrobial properties in vitro. Therefore, this novel design of low pH-triggered AgNPs releasing TNT-AL-AgNPs could be an infection-triggered antimicrobial releasing implant model to control peri-implant infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Staphylococcus aureus and Staphylococcus epidermidis infections on implants.

    PubMed

    Oliveira, W F; Silva, P M S; Silva, R C S; Silva, G M M; Machado, G; Coelho, L C B B; Correia, M T S

    2018-02-01

    Infections are one of the main reasons for removal of implants from patients, and usually need difficult and expensive treatments. Staphylococcus aureus and Staphylococcus epidermidis are the most frequently detected pathogens. We reviewed the epidemiology and pathogenesis of implant-related infections. Relevant studies were identified by electronic searching of the following databases: PubMed, ScienceDirect, Academic Google, and CAPES Journal Portal. This review reports epidemiological studies of implant infections caused by S. aureus and S. epidermidis. We discuss some methodologies used in the search for new compounds with antibiofilm activity and the main strategies for biomaterial surface modifications to avoid bacterial plaque formation and consequent infection. S. aureus and S. epidermidis are frequently involved in infections in catheters and orthopaedic/breast implants. Different methodologies have been used to test the potential antibiofilm properties of compounds; for example, crystal violet dye is widely used for in-vitro biofilm quantification due to its low cost and good reproducibility. Changes in the surface biomaterials are necessary to prevent biofilm formation. Some studies have investigated the immobilization of antibiotics on the surfaces of materials used in implants. Other approaches have been used as a way to avoid the spread of bacterial resistance to antimicrobials, such as the functionalization of these surfaces with silver and natural compounds, as well as the electrical treatment of these substrates. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Robotics in Orthopedics: A Brave New World.

    PubMed

    Parsley, Brian S

    2018-02-16

    Future health-care projection projects a significant growth in population by 2020. Health care has seen an exponential growth in technology to address the growing population with the decreasing number of physicians and health-care workers. Robotics in health care has been introduced to address this growing need. Early adoption of robotics was limited because of the limited application of the technology, the cumbersome nature of the equipment, and technical complications. A continued improvement in efficacy, adaptability, and cost reduction has stimulated increased interest in robotic-assisted surgery. The evolution in orthopedic surgery has allowed for advanced surgical planning, precision robotic machining of bone, improved implant-bone contact, optimization of implant placement, and optimization of the mechanical alignment. The potential benefits of robotic surgery include improved surgical work flow, improvements in efficacy and reduction in surgical time. Robotic-assisted surgery will continue to evolve in the orthopedic field. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Anti-infection activity of nanostructured titanium percutaneous implants with a postoperative infection model

    NASA Astrophysics Data System (ADS)

    Tan, Jing; Li, Yiting; Liu, Zhiyuan; Qu, Shuxin; Lu, Xiong; Wang, Jianxin; Duan, Ke; Weng, Jie; Feng, Bo

    2015-07-01

    The titanium percutaneous implants were widely used in clinic; however, they have an increased risk of infection since they breach the skin barrier. Lack of complete skin integration with the implants can cause infection and implant removal. In this work, three titania nanotubes (TNT) with different diameters, 50 nm (TNT-50), 100 nm (TNT-100) and 150 nm (TNT-150) arrays were prepared on titanium surfaces by anodization, pure titanium (pTi) was used as control. Samples were characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), and contact angle analysis. The antibacterial efficiency of TNT was evaluated in vitro against Staphylococcus aureus under the visible light. The results indicated that TNT-100 had the highest antibacterial efficiency under the visible light. Subsequently, TNT implants and pTi implants were placed subcutaneously to the dorsum of New Zealand White rabbits, 108 CFU S. aureus was inoculated into the implant sites 4 h after surgery. The TNF-alpha and IL-1alpha were determined using enzyme linked immunoassay (ELISA). TNT implants revealed less inflammatory factor release than pTi implants with or without injected S. aureus liquid. According to the histological results, the TNT implants displayed excellent tissue integration. Whereas, pTi implants were surrounded with fibrotic capsule, and the skin tissue was almost separated from the implant surface. Therefore, the TNT significantly inhibited the infection risk and enhanced tissue integration of the percutaneous implants compared to pTi. The immersion test in the culture medium suggested that one of causes be probably more proteins adsorbed on TNT than on pTi.

  1. Cutibacterium (formerly Propionibacterium) acnes infections associated with implantable devices.

    PubMed

    Gharamti, Amal A; Kanafani, Zeina A

    2017-12-01

    Cutibacterium acnes (C. acnes), a Gram-positive biofilm-forming rod implicated in acne vulgaris, is increasingly recognized for its role in implant-associated infections. The diagnosis of C. acnes implant-associated infections remains challenging. The optimal treatment is a combination of both surgical intervention and antibiotic therapy. Areas covered: In this review, we discuss the different types of implant-associated infections caused by C. acnes. We also highlight the clinical manifestations pertaining to the various sites of infection, and identify several risk factors previously reported in the literature. We then cover the diagnostic laboratory markers, such as IL-6 and AD-1, optimizing C. acnes recovery in culture, and the specific molecular techniques. Finally, we examine the various effective antibiotic regimens and identify some preventive methods against C. acnes infections. Expert commentary: Biomarkers such as IL-6 and AD-1 should be further investigated for the diagnosis of C. acnes implant-associated infections. The use of 16S rRNA gene sequencing and other molecular techniques should be further explored in this setting. Longer incubation periods should be requested whenever C. acnes infection is suspected. If the clinical suspicion is high, sonication of the excised implant should be encouraged. Research should focus on developing effective anti-biofilm agents. Finally, preventive methods such as hair removal prior to surgery should be further explored.

  2. Fabrication of Nanostructures on Implantable Biomaterials for Biocompatibility Enhancement and Infection Resistance

    NASA Astrophysics Data System (ADS)

    Liu, Luting

    An implant or implantable medical device, which is used to replace or restore the function of traumatized or degenerated tissues or organs, or acts as a fraction of or the whole biological structure, has been used in many different parts of the body for various applications (such as orthopedics, cardiovascular stents, or drug delivery systems for medical treatment). The best performance of the vast majority of implants is achieved when the biomaterial used promotes some biological activity (such as bone regeneration) while minimizing undesirable activity (such as infection, one of the most common reasons for the failure of many implants). The surface of the implant, through its interactions with proteins, bacteria and tissue forming cells, plays a critical role in the success or failure of the implant. Therefore, in this study, we sought to employ various nanofabrication techniques for tailoring implant surfaces to minimize bacteria and promote mammalian cell functions without using drugs. Titanium (Ti) and polyetheretherketone (PEEK) are commonly used biomaterials in orthopedic implants. Further surface modification is needed to support osseointegration while inhibiting bacteria attachment. Herein, temperature controlled atomic layer deposition (ALD) was utilized to provide unique nanostructured TiO2 coatings on commercial Ti. In vitro bacteria experiments revealed that the nano-TiO2 coatings showed promising antimicrobial efficacy towards Gram-positive bacteria (S. aureus), Gram-negative bacteria (E. coli) and antibiotic-resistant bacteria ( MRSA). Impressively, cell results indicated that this nano-TiO 2 coating stimulated osteoblast (or bone forming cell) adhesion and proliferation while suppressing undesirable fibroblast functions. The same procedure was performed on PEEK and also resulted in enhanced osteoblast functions and produced antimicrobial properties. In another study, to isolate the effect of surface chemistry on cell and bacteria activities, a

  3. The presence of both bone sialoprotein-binding protein gene and collagen adhesin gene as a typical virulence trait of the major epidemic cluster in isolates from orthopedic implant infections.

    PubMed

    Campoccia, Davide; Speziale, Pietro; Ravaioli, Stefano; Cangini, Ilaria; Rindi, Simonetta; Pirini, Valter; Montanaro, Lucio; Arciola, Carla Renata

    2009-12-01

    Staphylococcus aureus is a major, highly clonal, pathogen causing implant infections. This study aimed at investigating the diverse distribution of bacterial adhesins in most prevalent S. aureus strain types causing orthopaedic implant infections. 200 S. aureus isolates, categorized into ribogroups by automated ribotyping, i.e. rDNA restriction fragment length polymorphism analysis, were screened for the presence of a panel of adhesins genes. Within the collection of isolates, automated ribotyping detected 98 distinct ribogroups. For many ribogroups, characteristic tandem genes arrangements could be identified. In the predominant S. aureus cluster, enlisting 27 isolates, the bbp gene encoding bone sialoprotein-binding protein appeared a typical virulence trait, found in 93% of the isolates. Conversely, the bbp gene was identified in just 10% of the remaining isolates of the collection. In this cluster, co-presence of bbp with the cna gene encoding collagen adhesin was a pattern consistently observed. These findings indicate a crucial role of both these adhesins, able to bind the most abundant bone proteins, in the pathogenesis of orthopaedic implant infections, there where biomaterials interface bone tissues. This study suggests that specific adhesins may synergistically act in the onset of implant infections and that anti-adhesin strategies should be targeted to adhesins conjointly present.

  4. Co-precipitation of tobramycin into biomimetically coated orthopedic fixation pins employing submicron-thin seed layers of hydroxyapatite.

    PubMed

    Sörensen, Jan H; Lilja, Mirjam; Åstrand, Maria; Sörensen, Torben C; Procter, Philip; Strømme, Maria; Steckel, Hartwig

    2014-01-01

    The migration, loosening and cut-out of implants and nosocomial infections are current problems associated with implant surgery. New innovative strategies to overcome these issues are emphasized in today's research. The current work presents a novel strategy involving co-precipitation of tobramycin with biomimetic hydroxyapatite (HA) formation to produce implant coatings that control local drug delivery to prevent early bacterial colonization of the implant. A submicron- thin HA layer served as seed layer for the co-precipitation process and allowed for incorporation of tobramycin in the coating from a stock solution of antibiotic concentrations as high as 20 mg/ml. Concentrations from 0.5 to 20 mg/ml tobramycin and process temperatures of 37 °C and 60 °C were tested to assess the optimal parameters for a thin tobramycin- delivering HA coating on discs and orthopedic fixation pins. The morphology and thickness of the coating and the drug-release profile were evaluated via scanning electron microscopy and high performance liquid chromatography. The coatings delivered pharmaceutically relevant amounts of tobramycin over a period of 12 days. To the best of our knowledge, this is the longest release period ever observed for a fast-loaded biomimetic implant coating. The presented approach could form the foundation for development of combination device/antibiotic delivery vehicles tailored to meet well-defined clinical needs while combating infections and ensuring fast implant in-growth.

  5. [Effect of wound healing of orthopedic surgery in human immunodeficiency virus infected patients with perioperative adjuvant treatments].

    PubMed

    Sun, Sheng; Zhang, Yaoshen; Zhang, Qiang; Li, Xin; Wan, Gang; Zhao, Changsong; Cai, Juan; Yuan, Zheng

    2014-08-05

    To observe the early wound healing of orthopedic surgery in human immunodeficiency virus (HIV) carrier patients treated with optimized auxiliary treatments. During a period of 48 months, according to the inclusion and exclusion criteria plus CD4⁺ T lymphocyte count, the patients scheduled for orthopedic surgery (including HIV positive and negative) were divided into group A (HIV positive, CD4<500/ml) with optimized auxiliary treatments, group B (HIV positive, CD4 ≥ 500/ml) and group C (HIV negative) on prophylactic antibiotic therapy alone. Wound healing of 3 groups were observed postoperatively. The rates of clinical wound infection were compared among 3 groups. A total of 471 cases (n = 79, HIV+; n = 392, HIV-) were selected due to fresh fracture (n = 544, 77.28%), fracture of spine (n = 57, 12.31%), mal-union (n = 13, 2.76%), aseptic necrosis (n = 15, 3.18%) and osteoarthritis (n = 21, 4.46%). During surgery, early open reduction and plate screw internal fixation (group A, n = 23; group B, n = 21; group C, n = 274); pedicle screw internal fixation (group A, n = 5; group B, n = 6; group C, n = 47); total joint replacement (group A, n = 3; group B, n = 4; group C, n = 8); interlocking intramedullary nail fixation (group A, n = 7; group B, n = 4; group C, n = 35) and other operations (group A, n = 3; group B, n = 3; group C, n = 28). For infections, 2 cases (4.88%) were observed in group A, 3 (5.26%) in group B and 26 (6.63%) in group C. The differences were statistically insignificant. Reasonable perioperative adjuvant treatments, including use of antibiotic, nutritional supports, immunomodulators and anti-retroviral drugs, are offered to HIV infected patients undergoing orthopedic surgery. Their risks of postoperative wound infection may be controlled.

  6. Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients

    PubMed Central

    Johansen, Jens Brock; Jørgensen, Ole Dan; Møller, Mogens; Arnsbo, Per; Mortensen, Peter Thomas; Nielsen, Jens Cosedis

    2011-01-01

    Aims Infection is a serious complication of pacemaker (PM) systems. Although the rate of infection has been debated, the figures are largely unknown. We therefore studied the incidence of PM infection and its associated risk factors in the Danish population. Methods and results Since 1982, all PM implantation and removal procedures performed in Denmark have been prospectively recorded in the Danish Pacemaker Register. All patients (n = 46299) who underwent implantation between 1982 and 2007 were included. The total length of surveillance was 236 888 PM-years. The incidence of infection was calculated according to the total number of PM-years. The incidence of surgical site infection (≤365 days after PM implantation) was compared with later infection in first implant and replacement procedures. Multiple-record and multiple-event-per-subject proportional hazards analyses were used to identify the independent risk factors of PM infection. Surgical site infection occurred in 192 cases after first implantation (incidence rate 4.82/1000 PM-years), and in 133 cases after replacement (12.12/1000 PM-years). Infections occurring more than 365 days after the first implantation occurred in 153 cases (1.02/1000 PM-years), and in 118 cases after replacement (3.26/1000 PM-years). Independent factors associated with an increased risk of PM infection were a greater number of PM operations (including replacements), male sex, younger age, implantation during the earliest part of the study period, and absence of antibiotics (P< 0.001). Conclusion The overall risk of infection after PM implantation was low. A greater number of operations augmented the risk of infection. This should be taken into account when considering revisions of PM systems. PMID:21252172

  7. Polymeric nanofiber coating with tunable combinatorial antibiotic delivery prevents biofilm-associated infection in vivo

    PubMed Central

    Ashbaugh, Alyssa G.; Jiang, Xuesong; Zheng, Jesse; Tsai, Andrew S.; Kim, Woo-Shin; Thompson, John M.; Miller, Robert J.; Shahbazian, Jonathan H.; Wang, Yu; Dillen, Carly A.; Ordonez, Alvaro A.; Chang, Yong S.; Jain, Sanjay K.; Jones, Lynne C.; Sterling, Robert S.; Mao, Hai-Quan; Miller, Lloyd S.

    2016-01-01

    Bacterial biofilm formation is a major complication of implantable medical devices that results in therapeutically challenging chronic infections, especially in cases involving antibiotic-resistant bacteria. As an approach to prevent these infections, an electrospun composite coating comprised of poly(lactic-coglycolic acid) (PLGA) nanofibers embedded in a poly(ε-caprolactone) (PCL) film was developed to locally codeliver combinatorial antibiotics from the implant surface. The release of each antibiotic could be adjusted by loading each drug into the different polymers or by varying PLGA:PCL polymer ratios. In a mouse model of biofilm-associated orthopedic-implant infection, three different combinations of antibiotic-loaded coatings were highly effective in preventing infection of the bone/joint tissue and implant biofilm formation and were biocompatible with enhanced osseointegration. This nanofiber composite-coating technology could be used to tailor the delivery of combinatorial antimicrobial agents from various metallic implantable devices or prostheses to effectively decrease biofilm-associated infections in patients. PMID:27791154

  8. ATTITUDES OF ORTHOPEDIC SPECIALISTS TOWARD EFFECTS OF MEDICAL DEVICE PURCHASING.

    PubMed

    Lingg, Myriam; Merida-Herrera, Everth; Wyss, Kaspar; Durán-Arenas, Luis

    2017-01-01

    The aim of this study was to assess viewpoints of end-users concerning the purchasing process of high-risk medical devices and to discuss the relevance of health technology assessments (HTAs) at the hospital level and other potential areas for improvement of purchasing processes. We used a cross-sectional study and assessed the attitudes and thoughts of orthopedic specialists. The study took place between June and October 2015 in Mexico. We collected data from 187 orthopedic surgeons. Involvement of orthopedic specialists in purchasing was reported by 86 percent. However, clinical practice was perceived as negatively influenced by purchasing outcomes by 92 percent. The problems were described as: material failure; effectiveness of medical devices; obsolete medical device technology; incomplete provision of implant / instrument sets; delayed provision of implants and instruments. To prevent sub-standard outcomes of purchasing decisions, this study and the current literature suggest that technologies should be assessed during the purchasing process, end-users should be adequately involved, and decisions should be based on multiple criteria including clinical impact in the short-term (e.g., primary stability of implant) and long-term (e.g., survival of implant). The focus on Mexico is particularly novel and provides insights into a health system where HTA is mainly present at the macro level and can be used for the listing of medical device technologies in the standard list. This study concludes that Mexican stakeholders of the purchasing process underestimate the contribution of HTAs at the level of purchasing decisions. HTA in Mexico has improved over the past years but still requires more advancement.

  9. Enhanced osteoblast adhesion on nanostructured selenium compacts for anti-cancer orthopedic applications.

    PubMed

    Tran, Phong; Webster, Thomas J

    2008-01-01

    Metallic bone implants possess numerous problems limiting their long-term efficacy, such as poor prolonged osseointegration, stress shielding, and corrosion under in vivo environments. Such problems are compounded for bone cancer patients since numerous patients receive orthopedic implants after cancerous bone resection. Unfortunately, current orthopedic materials were not originally developed to simultaneously increase healthy bone growth (as in traditional orthopedic implant applications) while inhibiting cancerous bone growth. The long-term objective of the present research is to investigate the use of nano-rough selenium to prevent bone cancer from re-occurring while promoting healthy bone growth for this select group of cancer patients. Selenium is a well known anti-cancer chemical. However, what is not known is how healthy bone cells interact with selenium. To determine this, selenium, spherical or semispherical shots, were pressed into cylindrical compacts and these compacts were then etched using 1N NaOH to obtain various surface structures ranging from the micron, submicron to nano scales. Changes in surface chemistry were also analyzed. Through these etching techniques, results of this study showed that biologically inspired surface roughness values were created on selenium compacts to match that of natural bone roughness. Moreover, results showed that healthy bone cell adhesion increased with greater nanometer selenium roughness (more closely matching that of titanium). In this manner, this study suggests that nano-rough selenium should be further tested for orthopedic applications involving bone cancer treatment.

  10. Enhanced osteoblast adhesion on nanostructured selenium compacts for anti-cancer orthopedic applications

    PubMed Central

    Tran, Phong; Webster, Thomas J

    2008-01-01

    Metallic bone implants possess numerous problems limiting their long-term efficacy, such as poor prolonged osseointegration, stress shielding, and corrosion under in vivo environments. Such problems are compounded for bone cancer patients since numerous patients receive orthopedic implants after cancerous bone resection. Unfortunately, current orthopedic materials were not originally developed to simultaneously increase healthy bone growth (as in traditional orthopedic implant applications) while inhibiting cancerous bone growth. The long-term objective of the present research is to investigate the use of nano-rough selenium to prevent bone cancer from re-occurring while promoting healthy bone growth for this select group of cancer patients. Selenium is a well known anti-cancer chemical. However, what is not known is how healthy bone cells interact with selenium. To determine this, selenium, spherical or semispherical shots, were pressed into cylindrical compacts and these compacts were then etched using 1N NaOH to obtain various surface structures ranging from the micron, submicron to nano scales. Changes in surface chemistry were also analyzed. Through these etching techniques, results of this study showed that biologically inspired surface roughness values were created on selenium compacts to match that of natural bone roughness. Moreover, results showed that healthy bone cell adhesion increased with greater nanometer selenium roughness (more closely matching that of titanium). In this manner, this study suggests that nano-rough selenium should be further tested for orthopedic applications involving bone cancer treatment. PMID:18990948

  11. New Ti-Alloys and Surface Modifications to Improve the Mechanical Properties and the Biological Response to Orthopedic and Dental Implants: A Review

    PubMed Central

    Kirmanidou, Yvoni; Sidira, Margarita; Drosou, Maria-Eleni; Bennani, Vincent; Bakopoulou, Athina; Tsouknidas, Alexander; Michailidis, Nikolaos; Michalakis, Konstantinos

    2016-01-01

    Titanium implants are widely used in the orthopedic and dentistry fields for many decades, for joint arthroplasties, spinal and maxillofacial reconstructions, and dental prostheses. However, despite the quite satisfactory survival rates failures still exist. New Ti-alloys and surface treatments have been developed, in an attempt to overcome those failures. This review provides information about new Ti-alloys that provide better mechanical properties to the implants, such as superelasticity, mechanical strength, and corrosion resistance. Furthermore, in vitro and in vivo studies, which investigate the biocompatibility and cytotoxicity of these new biomaterials, are introduced. In addition, data regarding the bioactivity of new surface treatments and surface topographies on Ti-implants is provided. The aim of this paper is to discuss the current trends, advantages, and disadvantages of new titanium-based biomaterials, fabricated to enhance the quality of life of many patients around the world. PMID:26885506

  12. The influence of patient factors on patient-reported outcomes of orthopedic surgery involving implantable devices: a systematic review.

    PubMed

    Waheeb, Androu; Zywiel, Michael G; Palaganas, Marvilyn; Venkataramanan, Viji; Davis, Aileen M

    2015-02-01

    Recent evidence suggests that patient factors can influence response to medical and surgical treatment and may play an under-recognized role in predicting treatment outcomes. However, the current state of knowledge concerning potential associations following orthopedic surgery in particular is unclear. The purpose of the present study was to systematically review current literature to investigate the currently known associations between pre-operative patient factors and patient-reported outcomes following orthopedic surgery. A systematic review was performed of the PubMed database to identify original studies that investigated the relationships between one or more patient factors and patient-reported outcomes of primary orthopedic surgical procedures involving implantation of a medical device. A total of 10,174 records were identified, with 83 studies included in the final review. The most commonly assessed patient factors included age, sex, and body mass index (BMI), reported in 63%, 55%, and 48% of studies, respectively. The only other patient factors identified were socioeconomic status and race, both of which were assessed in a single study. Considerable heterogeneity was observed in the methods used to stratify subjects by patient factors, patient-reported outcome constructs assessed, and follow-up intervals. Only 10% of studies performed appropriate sample size or power calculations, only 51% used methodologies to control for potentially confounding factors, and 6% assessed responder status. Overall, variable and conflicting findings were seen. While female sex and increasing BMI did appear to be associated with worse absolute outcomes, these differences did not appear to be maintained when differences in baseline status were considered. No clear associations between age and outcomes were identified. The present understanding of these relationships between patient factors and patient-reported outcomes following orthopedic surgery is limited. There is a need

  13. Trends in Medicare Reimbursement for Orthopedic Procedures: 2000 to 2016.

    PubMed

    Eltorai, Adam E M; Durand, Wesley M; Haglin, Jack M; Rubin, Lee E; Weiss, Arnold-Peter C; Daniels, Alan H

    2018-03-01

    Understanding trends in reimbursement is critical to the financial sustainability of orthopedic practices. Little research has examined physician fee trends over time for orthopedic procedures. This study evaluated trends in Medicare reimbursements for orthopedic surgical procedures. The Medicare Physician Fee Schedule was examined for Current Procedural Terminology code values for the most common orthopedic and nonorthopedic procedures between 2000 and 2016. Prices were adjusted for inflation to 2016-dollar values. To assess mean growth rate for each procedure and subspecialty, compound annual growth rates were calculated. Year-to-year dollar amount changes were calculated for each procedure and subspecialty. Reimbursement trends for individual procedures and across subspecialties were compared. Between 2000 and 2016, annual reimbursements decreased for all orthopedic procedures examined except removal of orthopedic implant. The orthopedic procedures with the greatest mean annual decreases in reimbursement were shoulder arthroscopy/decompression, total knee replacement, and total hip replacement. The orthopedic procedures with the least annual reimbursement decreases were carpal tunnel release and repair of ankle fracture. Rate of Medicare procedure reimbursement change varied between subspecialties. Trauma had the smallest decrease in annual change compared with spine, sports, and hand. Annual reimbursement decreased at a significantly greater rate for adult reconstruction procedures than for any of the other subspecialties. These findings indicate that reimbursement for procedures has steadily decreased, with the most rapid decrease seen in adult reconstruction. [Orthopedics. 2018; 41(2):95-102.]. Copyright 2018, SLACK Incorporated.

  14. Bacterial adherence and biofilm formation on medical implants: a review.

    PubMed

    Veerachamy, Suganthan; Yarlagadda, Tejasri; Manivasagam, Geetha; Yarlagadda, Prasad Kdv

    2014-10-01

    Biofilms are a complex group of microbial cells that adhere to the exopolysaccharide matrix present on the surface of medical devices. Biofilm-associated infections in the medical devices pose a serious problem to the public health and adversely affect the function of the device. Medical implants used in oral and orthopedic surgery are fabricated using alloys such as stainless steel and titanium. The biological behavior, such as osseointegration and its antibacterial activity, essentially depends on both the chemical composition and the morphology of the surface of the device. Surface treatment of medical implants by various physical and chemical techniques are attempted in order to improve their surface properties so as to facilitate bio-integration and prevent bacterial adhesion. The potential source of infection of the surrounding tissue and antimicrobial strategies are from bacteria adherent to or in a biofilm on the implant which should prevent both biofilm formation and tissue colonization. This article provides an overview of bacterial biofilm formation and methods adopted for the inhibition of bacterial adhesion on medical implants. © IMechE 2014.

  15. Percutaneous Implants with Porous Titanium Dermal Barriers: An In Vivo Evaluation of Infection Risk

    PubMed Central

    Isackson, Dorthyann; McGill, Lawrence D.; Bachus, Kent N.

    2010-01-01

    Osseointegrated percutaneous implants are a promising prosthetic alternative for a subset of amputees. However, as with all percutaneous implants, they have an increased risk of infection since they breach the skin barrier. Theoretically, host tissues could attach to the metal implant creating a barrier to infection. When compared with smooth surfaces, it is hypothesized that porous surfaces improve the attachment of the host tissues to the implant, and decrease the infection risk. In this study, 4 titanium implants, manufactured with a percutaneous post and a subcutaneous disk, were placed subcutaneously on the dorsum of eight New Zealand White rabbits. Beginning at four weeks post-op, the implants were inoculated weekly with 108 CFU Staphylococcus aureus until signs of clinical infection presented. While we were unable to detect a difference in the incidence of infection of the porous metal implants, smooth surface (no porous coating) percutaneous and subcutaneous components had a 7-fold increased risk of infection compared to the implants with a porous coating on one or both components. The porous coated implants displayed excellent tissue ingrowth into the porous structures; whereas, the smooth implants were surrounded with a thick, organized fibrotic capsule that was separated from the implant surface. This study suggests that porous coated metal percutaneous implants are at a significantly lower risk of infection when compared to smooth metal implants. The smooth surface percutaneous implants were inadequate in allowing a long-term seal to develop with the soft tissue, thus increasing vulnerability to the migration of infecting microorganisms. PMID:21145778

  16. Nanomedicine applications in orthopedic medicine: state of the art

    PubMed Central

    Mazaheri, Mozhdeh; Eslahi, Niloofar; Ordikhani, Farideh; Tamjid, Elnaz; Simchi, Abdolreza

    2015-01-01

    The technological and clinical need for orthopedic replacement materials has led to significant advances in the field of nanomedicine, which embraces the breadth of nanotechnology from pharmacological agents and surface modification through to regulation and toxicology. A variety of nanostructures with unique chemical, physical, and biological properties have been engineered to improve the functionality and reliability of implantable medical devices. However, mimicking living bone tissue is still a challenge. The scope of this review is to highlight the most recent accomplishments and trends in designing nanomaterials and their applications in orthopedics with an outline on future directions and challenges. PMID:26451110

  17. Nanomedicine applications in orthopedic medicine: state of the art.

    PubMed

    Mazaheri, Mozhdeh; Eslahi, Niloofar; Ordikhani, Farideh; Tamjid, Elnaz; Simchi, Abdolreza

    2015-01-01

    The technological and clinical need for orthopedic replacement materials has led to significant advances in the field of nanomedicine, which embraces the breadth of nanotechnology from pharmacological agents and surface modification through to regulation and toxicology. A variety of nanostructures with unique chemical, physical, and biological properties have been engineered to improve the functionality and reliability of implantable medical devices. However, mimicking living bone tissue is still a challenge. The scope of this review is to highlight the most recent accomplishments and trends in designing nanomaterials and their applications in orthopedics with an outline on future directions and challenges.

  18. Antibacterial effect of royal jelly for preservation of implant-related spinal infection in rat.

    PubMed

    Gunaldi, Omur; Daglioglu, Yusuf Kenan; Tugcu, Bekir; Kizilyildirim, Suna; Postalci, Lutfi; Ofluoglu, Ender; Koksal, Fatih

    2014-01-01

    Implant-related infections are still a significant problem in spinal surgical procedures. Many drugs and methods have been tried to prevent implant-related infections. Our objective in this study was to evaluate whether royal jelly, which was found to hinder the growth of MRSA, has any preventive role in the prognosis of an infection in rats in an implant-related infection model. Rats were divided into 3 groups of eight rats. Group-1 consisted of rats that underwent only a spinal implant, group-2 included those rats that were inoculated bacteria together with a spinal implant and group-3 was administered royal jelly in addition to a spinal implant and infection. The amount of bacteria that grew in vertebral columns and implants was more in Group-2 than in Group-3, which meant that the number of bacteria colonies that grew was more quantitatively. This difference was found to be statistically significant in vertebral columns, but not in implants. Royal jelly could not fully prevent the MRSA infection in this model, but decreased the severity of infection noticeably. More objective and promising results may be obtained if royal jelly can be used at regular intervals in a different model to be designed with respect to implant-related infections.

  19. Improvements of anti-corrosion and mechanical properties of NiTi orthopedic materials by acetylene, nitrogen and oxygen plasma immersion ion implantation

    NASA Astrophysics Data System (ADS)

    Poon, Ray W. Y.; Ho, Joan P. Y.; Liu, Xuanyong; Chung, C. Y.; Chu, Paul K.; Yeung, Kelvin W. K.; Lu, William W.; Cheung, Kenneth M. C.

    2005-08-01

    Nickel-titanium shape memory alloys (NiTi) are useful materials in orthopedics and orthodontics due to their unique super-elasticity and shape memory effects. However, the problem associated with the release of harmful Ni ions to human tissues and fluids has been raising safety concern. Hence, it is necessary to produce a surface barrier to impede the out-diffusion of Ni ions from the materials. We have conducted acetylene, nitrogen and oxygen plasma immersion ion implantation (PIII) into NiTi alloys in an attempt to improve the surface properties. All the implanted and annealed samples surfaces exhibit outstanding corrosion and Ni out-diffusion resistance. Besides, the implanted layers are mechanically stronger than the substrate underneath. XPS analyses disclose that the layer formed by C2H2 PIII is composed of mainly TiCx with increasing Ti to C concentration ratios towards the bulk. The nitrogen PIII layer is observed to be TiN, whereas the oxygen PIII layer is composed of oxides of Ti4+, Ti3+ and Ti2+.

  20. Reducing infection risk in implant-based breast-reconstruction surgery: challenges and solutions

    PubMed Central

    Ooi, Adrian SH; Song, David H

    2016-01-01

    Implant-based procedures are the most commonly performed method for postmastectomy breast reconstruction. While donor-site morbidity is low, these procedures are associated with a higher risk of reconstructive loss. Many of these are related to infection of the implant, which can lead to prolonged antibiotic treatment, undesired additional surgical procedures, and unsatisfactory results. This review combines a summary of the recent literature regarding implant-related breast-reconstruction infections and combines this with a practical approach to the patient and surgery aimed at reducing this risk. Prevention of infection begins with appropriate reconstructive choice based on an assessment and optimization of risk factors. These include patient and disease characteristics, such as smoking, obesity, large breast size, and immediate reconstructive procedures, as well as adjuvant therapy, such as radiotherapy and chemotherapy. For implant-based breast reconstruction, preoperative planning and organization is key to reducing infection. A logical and consistent intraoperative and postoperative surgical protocol, including appropriate antibiotic choice, mastectomy-pocket creation, implant handling, and considered acellular dermal matrix use contribute toward the reduction of breast-implant infections. PMID:27621667

  1. Nanobiotechnology Perspectives on Prevention and Treatment of Ortho-paedic Implant Associated Infection.

    PubMed

    Borse, Vivek; Pawar, Vaishali; Shetty, Gautam; Mullaji, Arun; Srivastava, Rohit

    2016-01-01

    Implants are an inevitable part of orthopaedic surgery. However, implant associated infection remains a major challenge for orthopaedic surgeons and researchers. This review focuses on current options available for prevention of implant associated infection, their drawbacks and future promising applications of nanotechnology-based approaches. Nanobiotechnology has shown remarkable progress in recent years especially in biomaterials, diagnostics, and drug delivery system. Although several applications of nanobiotechnology in orthopaedics have been described, few have elaborated their role in the prevention of implant related infection in orthopaedics. Novel "smart" drug delivery systems that release antibiotics locally in response to stimuli such as pH, temperature, enzymes or antigens; implant surface modification on a nanoscale to inhibit bacterial adhesion and propagation at the surgical site and biological approaches such as gene therapy to neutralize bacterial virulence and biomolecules to inhibit the quorum sensing adhesion of bacteria and disruption of biofilms can be used effectively to prevent orthopaedic implant related bacterial infection.

  2. Designer Dual Therapy Nanolayered Implant Coatings Eradicate Biofilms and Accelerate Bone Tissue Repair.

    PubMed

    Min, Jouha; Choi, Ki Young; Dreaden, Erik C; Padera, Robert F; Braatz, Richard D; Spector, Myron; Hammond, Paula T

    2016-04-26

    Infections associated with orthopedic implants cause increased morbidity and significant healthcare cost. A prolonged and expensive two-stage procedure requiring two surgical steps and a 6-8 week period of joint immobilization exists as today's gold standard for the revision arthroplasty of an infected prosthesis. Because infection is much more common in implant replacement surgeries, these issues greatly impact long-term patient care for a continually growing part of the population. Here, we demonstrate that a single-stage revision using prostheses coated with self-assembled, hydrolytically degradable multilayers that sequentially deliver the antibiotic (gentamicin) and the osteoinductive growth factor (BMP-2) in a time-staggered manner enables both eradication of established biofilms and complete and rapid bone tissue repair around the implant in rats with induced osteomyelitis. The nanolayered construct allows precise independent control of release kinetics and loading for each therapeutic agent in an infected implant environment. Antibiotics contained in top layers can be tuned to provide a rapid release at early times sufficient to eliminate infection, followed by sustained release for several weeks, and the underlying BMP-2 component enables a long-term sustained release of BMP-2, which induced more significant and mechanically competent bone formation than a short-term burst release. The successful growth factor-mediated osteointegration of the multilayered implants with the host tissue improved bone-implant interfacial strength 15-fold when compared with the uncoated one. These findings demonstrate the potential of this layered release strategy to introduce a durable next-generation implant solution, ultimately an important step forward to future large animal models toward the clinic.

  3. Preventing Bacterial Infections using Metal Oxides Nanocoatings on Bone Implant

    NASA Astrophysics Data System (ADS)

    Duceac, L. D.; Straticiuc, S.; Hanganu, E.; Stafie, L.; Calin, G.; Gavrilescu, S. L.

    2017-06-01

    Nowadays bone implant removal is caused by infection that occurs around it possibly acquired after surgery or during hospitalization. The purpose of this study was to reveal some metal oxides applied as coatings on bone implant thus limiting the usual antibiotics-resistant bacteria colonization. Therefore ZnO, TiO2 and CuO were synthesized and structurally and morphologically analized in order to use them as an alternative antimicrobial agents deposited on bone implant. XRD, SEM, and FTIR characterization techniques were used to identify structure and texture of these nanoscaled metal oxides. These metal oxides nanocoatings on implant surface play a big role in preventing bacterial infection and reducing surgical complications.

  4. Implant salvage in breast reconstruction with severe peri-prosthetic infection.

    PubMed

    Meybodi, Farid; Sedaghat, Negin; French, James; Keighley, Caitlin; Mitchell, David; Elder, Elisabeth

    2017-12-01

    Although treatment of mild peri-prosthetic infection in implant-based breast reconstruction results in high rates of resolution, successful management of severe peri-prosthetic infection remains a significant challenge. In this case series, a protocol utilizing a novel dressing - negative pressure wound therapy with instillation (NPWTi) - for the management of severe peri-prosthetic infection in breast reconstruction patients is described. This is an operative technique involving: (i) explantation of the breast prosthesis and application of the NPWTi dressing to the implant pocket; (ii) change of the NPWTi dressing; (iii) intraoperative fluid/tissue cultures; and (iv) reimplantation of the breast prosthesis when cultures yield no growth. This protocol was utilized in six cases of severe peri-prosthetic infection in five patients with immediate breast reconstruction for breast cancer or risk-reducing surgery. Cultures of fluid/tissue grew typical and/or unusual organisms. Only one case did not yield an organism. The hospital length of stay upon completion of the protocol ranged from 7-16 days (mean, 12 days). Successful implant salvage was achieved in five of six cases. The protocol was aborted in one case to allow for completion of adjuvant chemotherapy. Early findings from this case series suggest that in cases of severe peri-prosthetic infection this novel operative protocol may result in successful implant salvage for breast reconstruction patients. Further studies are needed to more fully elaborate the role of NPWTi to achieve implant salvage in challenging cases of peri-prosthetic infection. © 2015 Royal Australasian College of Surgeons.

  5. Waterless Hand Rub Versus Traditional Hand Scrub Methods for Preventing the Surgical Site Infection in Orthopedic Surgery.

    PubMed

    Iwakiri, Kentaro; Kobayashi, Akio; Seki, Masahiko; Ando, Yoshiyuki; Tsujio, Tadao; Hoshino, Masatoshi; Nakamura, Hiroaki

    2017-11-15

    MINI: Fourteen hundred consecutive patients were investigated for evaluating the utility of waterless hand rub before orthopaedic surgery. The risk in the surgical site infection incidence was the same, but costs of liquids used for hand hygiene were cheaper and the hand hygiene time was shorter for waterless protocol, compared with traditional hand scrub. A retrospective cohort study with prospectively collected data. The aim of this study was to compare SSI incidences, the cost of hand hygiene agents, and hand hygiene time between the traditional hand scrub and the waterless hand rub protocols before orthopedic surgery. Surgical site infections (SSI) prolong hospitalization and are a leading nosocomial cause of morbidity and a source of excess cost. Recently, a waterless hand rub protocol comprising alcohol based chlorhexidine gluconate for use before surgery was developed, but no studies have yet examined its utility in orthopedic surgery. Fourteen hundred consecutive patients who underwent orthopedic surgery (spine, joint replacement, hand, and trauma surgeries) in our hospital since April 1, 2012 were included. A total of 712 cases underwent following traditional hand scrub between April 1, 2012 and April 30, 2013 and 688 cases underwent following waterless hand rub between June 1, 2013 and April 30, 2014. We compared SSI incidences within all and each subcategory between two hand hygiene protocols. All patients were screened for SSI within 1 year after surgery. We compared the cost of hand hygiene agents and hand hygiene time between two groups. The SSI incidences were 1.3% (9 of 712) following the traditional protocol (2 deep and 7 superficial infections) and 1.1% (8 of 688) following the waterless protocol (all superficial infections). There were no significant differences between the two groups. The costs of liquids used for one hand hygiene were about $2 for traditional hand scrub and less than $1 for waterless hand rub. The mean hand hygiene time was 264

  6. Development of an optically-based tension-indicating implanted orthopedic screw with a luminescent spectral ruler

    NASA Astrophysics Data System (ADS)

    Ravikumar, Nakul; Rogalski, Melissa M.; Benza, Donny; Lake, Joshua; Urban, Matthew; Pelham, Hunter; Anker, Jeffrey N.; DesJardins, John D.

    2017-03-01

    An orthopaedic screw was designed with an optical tension-indicator to non-invasively quantify screw tension and monitor the load sharing between the bone and the implant. The screw both applies load to the bone, and measures this load by reporting the strain on the screw. The screw contains a colorimetric optical encoder that converts axial strain into colorimetric changes visible through the head of the screw, or luminescent spectral changes that are detected through tissue. Screws were tested under cyclic mechanical loading to mimic in-vivo conditions to verify the sensitivity, repeatability, and reproducibility of the sensor. In the absence to tissue, color was measured using a digital camera as a function of axial load on a stainless steel cannulated (hollow) orthopedic screw, modified by adding a passive colorimetric strain gauge through the central hole. The sensor was able to quantify clinically-relevant bone healing strains. The sensor exhibited good repeatability and reproducibility but also displayed hysteresis due to the internal mechanics of the screw. The strain indicator was also modified for measurement through tissue by replacing the reflective colorimetric sensor with a low-background X-ray excited optical luminescence signal. Luminescent spectra were acquired through 6 mm of chicken breast tissue. Overall, this research shows feasibility for a unique device which quantifies the strain on an orthopedic screw. Future research will involve reducing hysteresis by changing the mechanism of strain transduction in the screw, miniaturizing the luminescent strain gauge, monitoring bending as well as tension, using alternative luminescent spectral rulers based upon near infrared fluorescence or upconversion luminescence, and application to monitoring changes in pretension and load sharing during bone healing.

  7. Leadless Cardiac Pacemaker Implantation After Lead Extraction in Patients With Severe Device Infection.

    PubMed

    Kypta, Alexander; Blessberger, Hermann; Kammler, Juergen; Lambert, Thomas; Lichtenauer, Michael; Brandstaetter, Walter; Gabriel, Michael; Steinwender, Clemens

    2016-09-01

    Conventional pacemaker therapy is limited by short- and long-term complications, most notably device infection. Transcatheter pacing systems (TPS) may be beneficial in this kind of patients as they eliminate the need for a device pocket and leads and thus may reduce the risk of re-infection. We assessed a novel procedure in 6 patients with severe device infection who were pacemaker dependent. After lead extraction a single chamber TPS was implanted into the right ventricle. Of the 6 patients who underwent lead extraction due to severe device infection at our institution, 3 were diagnosed with a pocket infection only, whereas the other 3 showed symptoms of both pocket and lead infection. Successful lead extraction and TPS implantation was accomplished in all patients. Four patients were bridged with a temporary pacemaker between 2 hours and 2 days after lead extraction, whereas 2 patients had the TPS implanted during the same procedure just before traditional pacemaker system removal. All patients stayed free of infection during the follow-up period of 12 weeks. An additional positron emission tomography scan was performed in each patient and indicated no signs of an infection around the TPS. Transcather pacemaker implantation was safe and feasible in 6 patients and did not result in re-infection even if implanted before removal of the infected pacemaker system within the same procedure. Therefore, implantation of a TPS may be an option for patients with severe device infection, especially in those with blocked venous access or who are pacemaker dependent. © 2016 Wiley Periodicals, Inc.

  8. Comparison of immediate implant placement in infected and non-infected extraction sockets: a systematic review and meta-analysis.

    PubMed

    Lee, Jungwon; Park, Dueun; Koo, Ki-Tae; Seol, Yang-Jo; Lee, Yong-Moo

    2018-04-03

    This review aimed to investigate the feasibility of immediate implant placement in infected extraction sockets. We performed electronic and manual searches up to March 2017 to obtain data from randomized controlled trials (RCTs) and nonrandomized controlled clinical trials (CCTs). Using a fixed-effects model to assess the difference in survival rate (primary outcome), we evaluated the risk difference for immediate implant placement in infected and non-infected sites. We estimated the weighted mean differences (WMDs) of the change in marginal bone loss (MBL), probing depth (PD), modified bleeding index (mBI), marginal gingival level (MGL) and width of keratinized gingiva (WKG) at baseline and latest follow-up. In total, five studies (0 RCT, five CCTs) were included in the systematic review and three studies were included in the meta-analysis. The risk difference for immediate implant placement in an infected extraction socket compared with that in a non-infected socket was -0.02. WMDs for MBL, PD, mBI, MGL and WKG between the two groups were 0.32, 0.12, 0.07, -0.06, 0.20 and 0.51, respectively. No statistical differences were observed between the two groups, except for the change in WKG. Implants can be placed in infected extraction sockets after thorough socket debridement. For aesthetics, WKG should be considered when performing immediate implant placement in infected sites.

  9. Diamond-like carbon coatings with zirconium-containing interlayers for orthopedic implants.

    PubMed

    Choudhury, Dipankar; Lackner, Juergen; Fleming, Robert A; Goss, Josh; Chen, Jingyi; Zou, Min

    2017-04-01

    Six types of diamond-like carbon (DLC) coatings with zirconium (Zr)-containing interlayers on titanium alloy (Ti-6Al-4V) were investigated for improving the biotribological performance of orthopedic implants. The coatings consist of three layers: above the substrate a layer stack of 32 alternating Zr and ZrN sublayers (Zr:ZrN), followed by a layer comprised of Zr and DLC (Zr:DLC), and finally a N-doped DLC layer. The Zr:ZrN layer is designed for increasing load carrying capacity and corrosion resistance; the Zr:DLC layer is for gradual transition of stress, thus enhancing layer adhesion; and the N-doped DLC layer is for decreasing friction, squeaking noises and wear. Biotribological experiments were performed in simulated body fluid employing a ball-on-disc contact with a Si 3 N 4 ball and a rotational oscillating motion to mimic hip motion in terms of gait angle, dynamic contact pressures, speed and body temperature. The results showed that the Zr:DLC layer has a substantial influence on eliminating delamination of the DLC from the substrates. The DLC/Si 3 N 4 pairs significantly reduced friction coefficient, squeaking noise and wear of both the Si 3 N 4 balls and the discs compared to those of the Ti-6Al-4V/Si 3 N 4 pair after testing for a duration that is equivalent to one year of hip motion in vivo. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A Case of Orbital Abscess following Porous Orbital Implant Infection

    PubMed Central

    Hong, Seung Woo; Paik, Ji-Sun; Kim, So-Youl

    2006-01-01

    Purpose We present a case of orbital abscess following porous orbital implant infection in a 73-year-old woman with rheumatoid arthritis. Methods Just one month after a seemingly uncomplicated enucleation and porous polyethylene (Medpor®) orbital implant surgery, implant exposure developed with profuse pus discharge. The patient was unresponsive to implant removal and MRI confirmed the presence of an orbital pus pocket. Despite extirpation of the four rectus muscles, inflammatory granulation debridement and abscess drainage, another new pus pocket developed. Results After partial orbital exenteration, the wound finally healed well without any additional abscess formation. Conclusions A patient who has risk factors for delayed wound healing must be examined thoroughly and extreme care such as exenteration must be taken if there is persistent infection. PMID:17302210

  11. A Cellular Automata Model of Infection Control on Medical Implants

    PubMed Central

    Prieto-Langarica, Alicia; Kojouharov, Hristo; Chen-Charpentier, Benito; Tang, Liping

    2011-01-01

    S. epidermidis infections on medically implanted devices are a common problem in modern medicine due to the abundance of the bacteria. Once inside the body, S. epidermidis gather in communities called biofilms and can become extremely hard to eradicate, causing the patient serious complications. We simulate the complex S. epidermidis-Neutrophils interactions in order to determine the optimum conditions for the immune system to be able to contain the infection and avoid implant rejection. Our cellular automata model can also be used as a tool for determining the optimal amount of antibiotics for combating biofilm formation on medical implants. PMID:23543851

  12. Comparison between mixed and laminar airflow systems in operating rooms and the influence of human factors: experiences from a Swedish orthopedic center.

    PubMed

    Erichsen Andersson, Annette; Petzold, Max; Bergh, Ingrid; Karlsson, Jón; Eriksson, Bengt I; Nilsson, Kerstin

    2014-06-01

    The importance of laminar airflow systems in operating rooms as protection from surgical site infections has been questioned. The aim of our study was to explore the differences in air contamination rates between displacement ventilation and laminar airflow systems during planned and acute orthopedic implant surgery. A second aim was to compare the influence of the number of people present, the reasons for traffic flow, and the door-opening rates between the 2 systems. Active air sampling and observations were made during 63 orthopedic implant operations. The laminar airflow system resulted in a reduction of 89% in colony forming units in comparison with the displacement system (P < .001). The air samples taken in the preparation rooms showed high levels of bacterial growth (≈ 40 CFU/m(3)). Our study shows that laminar airflow-ventilated operating rooms offer high-quality air during surgery, with very low levels of colony forming units close to the surgical wound. The continuous maintenance of laminar air flow and other technical systems are crucial, because minor failures in complex systems like those in operating rooms can result in a detrimental effect on air quality and jeopardize the safety of patients. The technical ventilation solutions are important, but they do not guarantee clean air, because many other factors, such as the organization of the work and staff behavior, influence air cleanliness. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  13. Selective laser melting porous metallic implants with immobilized silver nanoparticles kill and prevent biofilm formation by methicillin-resistant Staphylococcus aureus.

    PubMed

    van Hengel, Ingmar A J; Riool, Martijn; Fratila-Apachitei, Lidy E; Witte-Bouma, Janneke; Farrell, Eric; Zadpoor, Amir A; Zaat, Sebastian A J; Apachitei, Iulian

    2017-09-01

    Implant-associated infection and limited longevity are two major challenges that orthopedic devices need to simultaneously address. Additively manufactured porous implants have recently shown tremendous promise in improving bone regeneration and osseointegration, but, as any conventional implant, are threatened by infection. In this study, we therefore used rational design and additive manufacturing in the form of selective laser melting (SLM) to fabricate porous titanium implants with interconnected pores, resulting in a 3.75 times larger surface area than corresponding solid implants. The SLM implants were biofunctionalized by embedding silver nanoparticles in an oxide surface layer grown using plasma electrolytic oxidation (PEO) in Ca/P-based electrolytes. The PEO layer of the SLM implants released silver ions for at least 28 days. X-ray diffraction analysis detected hydroxyapatite on the SLM PEO implants but not on the corresponding solid implants. In vitro and ex vivo assays showed strong antimicrobial activity of these novel SLM PEO silver-releasing implants, without any signs of cytotoxicity. The rationally designed SLM porous implants outperformed solid implants with similar dimensions undergoing the same biofunctionalization treatment. This included four times larger amount of released silver ions, two times larger zone of inhibition, and one additional order of magnitude of reduction in numbers of CFU in an ex vivo mouse infection model. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Transcriptional profile of human macrophages stimulated by ultra-high molecular weight polyethylene particulate debris of orthopedic implants uncovers a common gene expression signature of rheumatoid arthritis.

    PubMed

    Terkawi, Mohamad Alaa; Hamasaki, Masanari; Takahashi, Daisuke; Ota, Masahiro; Kadoya, Ken; Yutani, Tomoyo; Uetsuki, Keita; Asano, Tsuyoshi; Irie, Tohru; Arai, Ryuta; Onodera, Tomohiro; Takahata, Masahiko; Iwasaki, Norimasa

    2018-01-01

    Osteolysis is a serious postoperative complication of total joint arthroplasty that leads to aseptic loosening and surgical revision. Osteolysis is a chronic destructive process that occurs when host macrophages recognize implant particles and release inflammatory mediators that increase bone-resorbing osteoclastic activity and attenuate bone-formation osteoblastic activity. Although much progress has been made in understanding the molecular responses of macrophages to implant particles, the pathways/signals that initiate osteolysis remain poorly characterized. Transcriptomics and gene-expression profiling of these macrophages may unravel key mechanisms in the pathogenesis of osteolysis and aid the identification of molecular candidates for therapeutic intervention. To this end, we analyzed the transcriptional profiling of macrophages exposed to ultra-high molecular weight polyethylene (UHMWPE) particles, the most common components used in bearing materials of orthopedic implants. Regulated genes in stimulated macrophages were involved in cytokine, chemokine, growth factor and receptor activities. Gene enrichment analysis suggested that stimulated macrophages elicited common gene expression signatures for inflammation and rheumatoid arthritis. Among the regulated genes, tumor necrosis factor superfamily member 15 (TNFSF15) and chemokine ligand 20 (CCL20) were further characterized as molecular targets involved in the pathogenesis of osteolysis. Treatment of monocyte cultures with TNFSF15 and CCL20 resulted in an increase in osteoclastogenesis and bone-resorbing osteoclastic activity, suggesting their potential contribution to loosening between implants and bone tissues. Implant loosening due to osteolysis is the most common mode of arthroplasty failure and represents a great challenge to orthopedic surgeons and a significant economic burden for patients and healthcare services worldwide. Bone loss secondary to a local inflammatory response initiated by particulate

  15. Development of nanofluorapatite polymer-based composite for bioactive orthopedic implants and prostheses

    PubMed Central

    Hu, Gangfeng; Wang, Hui; Yao, Xiaocong; Bi, Dawei; Zhu, Gang; Tang, Songchao; Wei, Jie; Yang, Lili; Tong, Peijian; Xiao, Luwei

    2014-01-01

    Fluorapatite with low solubility is a promising biomaterial due to its structure, which is similar to hydroxyapatite. In this study a bioactive composite of nanofluorapatite (n-FA) and polyamide 12 (PA12) was fabricated. The results revealed that the mechanical properties (such as compressive strength and elastic modulus), hydrophilicity, and antibacterial properties of n-FA/PA12 composite were obviously improved by adding n-FA into PA12 as compared with PA12. In addition, cell proliferation of MC3T3-E1 cells cultured on n-FA/PA12 composite was significantly higher than with PA12, and alkaline phosphatase activity of MC3T3-E1 cells on the n-FA/PA12 composite was expressed at obviously higher levels as compared with PA12. The results suggest that n-FA/PA12 composite could support cell proliferation and differentiation, showing good cytocompatibility. Histological evaluation indicates that n-FA/PA12 composite enhances the efficiency of new bone formation with the introduction of n-FA into PA12, and the quantity of the newly formed bone for n-FA/PA12 composite is significantly higher than with PA12. In conclusion, n-FA/PA12 composite exhibits good biocompatibility and osteogenesis, which might be used for various orthopedic prostheses and dental implants. PMID:25143735

  16. Orthopedic surgery.

    PubMed

    Gehrig, Laura M B

    2011-09-01

    Orthopedic surgery is a specialty of surgery dedicated to the prevention, diagnosis, and treatment of diseases and injuries of the musculoskeletal system in all age groups. Careers in orthopedic surgery span the spectrum from general orthopedics to those of subspecialty expertise in orthopedic trauma, hand, pediatrics, total joint, foot and ankle, sports medicine, and oncology to name a few. Copyright © 2011. Published by Elsevier Inc.

  17. Clinical retrospective study of self-reported penicillin allergy on dental implant failures and infections.

    PubMed

    French, David; Noroozi, Mehdi; Shariati, Batoul; Larjava, Hannu

    2016-01-01

    The aim of this retrospective study was to investigate whether self-reported allergy to penicillin may contribute to a higher rate of postsurgical infection and implant failure. This retrospective, non-interventional, open cohort study reports on implant survival and infection complications of 5,576 implants placed in private practice by one periodontist, and includes 4,132 implants that were followed for at least 1 year. Logistic regression was applied to examine the relationship between self-reported allergy to penicillin and implant survival, while controlling for potential confounders such as smoking, implant site, bone augmentation, loading protocol, immediate implantation, and bone level at baseline. The cumulative survival rate (CSR) was calculated according to the life table method and the Cox proportional hazard model was fitted to data. Out of 5,106 implants placed in patients taking penicillin it was found that 0.8% failed, while 2.1% failed of the 470 implants placed for patients with self-reported allergy to penicillin (P = .002). Odds of failure for implants placed in penicillin-allergic patients were 3.1 times higher than in non-allergic patients. For immediate implant placement, penicillin-allergic patients had a failure rate 10-times higher than the non-allergic cohort. Timing of implant failure occurring within 6 months following implantation was 80% in the penicillin-allergic group versus 54% in the non-allergic group. From the 48 implant sites showing postoperative infection: penicillin-allergic patients had an infection rate of 3.4% (n = 16/470) versus 0.6% in the non-allergic group (n = 32/5,106) (P < .05). Self-reported penicillin allergy was associated with a higher rate of infection, and primarily affected early implant failure.

  18. Dental Implant Surgery

    MedlinePlus

    ... supplements. If you have certain heart conditions or orthopedic implants, your doctor may prescribe antibiotics before surgery ... trademarks of Mayo Foundation for Medical Education and Research. © 1998-2018 Mayo Foundation for Medical Education and ...

  19. Early infection risk with primary versus staged Hemodialysis Reliable Outflow (HeRO) graft implantation.

    PubMed

    Griffin, Andrew S; Gage, Shawn M; Lawson, Jeffrey H; Kim, Charles Y

    2017-01-01

    This study evaluated whether the use of a staged Hemodialysis Reliable Outflow (HeRO; Merit Medical, South Jordan, Utah) implantation strategy incurs increased early infection risk compared with conventional primary HeRO implantation. A retrospective review was performed of 192 hemodialysis patients who underwent HeRO graft implantation: 105 patients underwent primary HeRO implantation in the operating room, and 87 underwent a staged implantation where a previously inserted tunneled central venous catheter was used for guidewire access for the venous outflow component. Within the staged implantation group, 32 were performed via an existing tunneled hemodialysis catheter (incidentally staged), and 55 were performed via a tunneled catheter inserted across a central venous occlusion in an interventional radiology suite specifically for HeRO implantation (intentionally staged). Early infection was defined as episodes of bacteremia or HeRO infection requiring resection ≤30 days of HeRO implantation. For staged HeRO implantations, the median interval between tunneled catheter insertion and conversion to a HeRO graft was 42 days. The overall HeRO-related infection rate ≤30 days of implantation was 8.6% for primary HeRO implantation and 2.3% for staged implantations (P = .12). The rates of early bacteremia and HeRO resection requiring surgical resection were not significantly different between groups (P = .19 and P = .065, respectively), nor were age, gender, laterality, anastomosis to an existing arteriovenous access, human immunodeficiency virus status, diabetes, steroids, chemotherapy, body mass index, or graft location. None of the patient variables, techniques, or graft-related variables correlated significantly with the early infection rate. The staged HeRO implantation strategy did not result in an increased early infection risk compared with conventional primary implantation and is thus a reasonable strategy for HeRO insertion in hemodialysis patients

  20. Pedicle screw loosening is correlated to chronic subclinical deep implant infection: a retrospective database analysis.

    PubMed

    Leitner, Lukas; Malaj, Isabella; Sadoghi, Patrick; Amerstorfer, Florian; Glehr, Mathias; Vander, Klaus; Leithner, Andreas; Radl, Roman

    2018-04-13

    Spinal fusion is used for treatment of spinal deformities, degeneration, infection, malignancy, and trauma. Reduction of motion enables osseous fusion and permanent stabilization of segments, compromised by loosening of the pedicle screws (PS). Deep implant infection, biomechanical, and chemical mechanisms are suspected reasons for loosening of PS. Study objective was to investigate the frequency and impact of deep implant infection on PS loosening. Intraoperative infection screening from wound and explanted material sonication was performed during revision surgeries following dorsal stabilization. Case history events and factors, which might promote implant infections, were included in this retrospective survey. 110 cases of spinal metal explantation were included. In 29.1% of revision cases, infection screening identified a germ, most commonly Staphylococcus (53.1%) and Propionibacterium (40.6%) genus. Patients screened positive had a significant higher number of previous spinal operations and radiologic loosening of screws. Patients revised for adjacent segment failure had a significantly lower rate of positive infection screening than patients revised for directly implant associated reasons. Removal of implants that revealed positive screening effected significant pain relief. Chronic implant infection seems to play a role in PS loosening and ongoing pain, causing revision surgery after spinal fusion. Screw loosening and multiple prior spinal operations should be suspicious for implant infection after spinal fusion when it comes to revision surgery. These slides can be retrieved under Electronic Supplementary Material.

  1. Clinical and Microbiological Characterization of Late Breast Implant Infections after Reconstructive Breast Cancer Surgery.

    PubMed

    Franchelli, Simonetta; Pesce, Marianna; Savaia, Serena; Marchese, Anna; Barbieri, Ramona; Baldelli, Ilaria; De Maria, Andrea

    2015-10-01

    Implant infections represent a relevant problem after immediate breast cancer reconstruction. In addition to difficulties in distinguishing early infections from other post-surgical complications (such as hematoma, seroma, and liponecrosis) late breast implant infections still represent a grey area of our knowledge with regards to heir definition and management. To address this issue, we prospectively monitored breast cancer patients at their center. Between February 1, 2009, and May 31, 2013, we enrolled all patients undergoing breast implant reconstruction or expander-to-prosthesis substitution. Patients without at least 6 mo of post-operative observation were excluded. We collected data from patient records including age, days from surgery (DFS), chemotherapy/radiotherapy, infecting microorganism, type of implant, antibiotic management and eventual implant removal. Sixty days from surgery were defined as the clinical threshold between early and late infection. Infections were further classified according to a graded scale into possible, probable and microbiologically proved. Seventy-eight infections were recorded out of 766 surgical procedures (10.2%). Fifty-three (67%) cases occurred early ≤60 DFS, and 25 (33%) occurred late (i.e., beyond 60 d). By defining infection types as possible, probable or proved, the majority of late infections were classified as proved (84%) compared with 56% of early infections (p=0.0014). Microbiological isolate distribution was similar in proved early infections compared with proved late infections. Among late infections, a delayed occurrence was observed after prosthesis placement compared with expander insertion. Late infections were fraught with lower treatment success rates (12% vs. 41%, p=0.009). Late infection represents a consistent proportion of infections after immediate breast implant reconstruction or prosthesis placement and bear lower chance of salvage after treatment. An increased attention is warranted to

  2. Antimicrobial delivery systems for local infection prophylaxis in orthopedic- and trauma surgery.

    PubMed

    ter Boo, Gert-Jan A; Grijpma, Dirk W; Moriarty, Thomas F; Richards, Robert G; Eglin, David

    2015-06-01

    Infectious complications occur in a minor but significant portion of the patients undergoing joint replacement surgery or fracture fixation, particularly those with severe open fractures, those undergoing revision arthroplasty or those at elevated risk because of poor health status. Once established, infections are difficult to eradicate, especially in the case of bacterial biofilm formation on implanted hardware. Local antibiotic carriers offer the prospect of controlled delivery of antibiotics directly in target tissues and implant, without inducing toxicity in non-target organs. Polymeric carriers have been developed to optimize the release and targeting of antibiotics. Passive polymeric carriers release antibiotics by diffusion and/or upon degradation, while active polymeric carriers release their antibiotics upon stimuli provided by bacterial pathogens. Additionally, some polymeric carriers gelate in-situ in response to physiological stimuli to form a depot for antibiotic release. As antibiotic resistance has become a major issue, also other anti-infectives such as silver and antimicrobial peptides have been incorporated in research. Currently, several antibiotic loaded biomaterials for local infection prophylaxis are available for use in the clinic. Here we review their advantages and limitations and provide an overview of new materials emerging that may overcome these limitations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Sustained release vancomycin-coated titanium alloy using a novel electrostatic dry powder coating technique may be a potential strategy to reduce implant-related infection.

    PubMed

    Han, Jing; Yang, Yi; Lu, Junren; Wang, Chenzhong; Xie, Youtao; Zheng, Xuebin; Yao, Zhenjun; Zhang, Chi

    2017-07-24

    In order to tackle the implant-related infection, a novel way was developed in this study to coat vancomycin particles mixed with controlled release coating materials onto the surface of titanium alloy by using an electrostatic dry powder coating technique. To characterize this sustained release antibacterial coating, surface morphology, in vitro and in vivo drug release were sequentially evaluated. In vitro cytotoxicity was tested by Cell Counting Kit-8 (CCK-8) assay and cytological changes were observed by inverted microscope. The antibacterial properties against MRSA, including a bacterial growth inhibition assay and a colony-counting test by spread plate method were performed. Results indicated that the vancomycin-coated sample was biocompatible for Human osteoblast cell line MG-63 and displayed effective antibacterial ability against MRSA. The coating film was revealed uniform by scanning electron microscopy. Both the in vitro and in vivo drug release kinetics showed an initially high release rate, followed by an extended period of sustained drug release over 7 days. These results suggest that with good biocompatibility and antibacterial ability, the sustained release antibacterial coating of titanium alloy using our novel electrostatic dry powder coating process may provide a promising candidate for the treatment of orthopedic implant-related infection.

  4. Sonication technique improves microbiological diagnosis in patients treated with antibiotics before surgery for prosthetic joint infections.

    PubMed

    Scorzolini, Laura; Lichtner, Miriam; Iannetta, Marco; Mengoni, Fabio; Russo, Gianluca; Panni, Alfredo Schiavone; Vasso, Michele; Vasto, Michele; Bove, Marco; Villani, Ciro; Mastroianni, Claudio M; Vullo, Vincenzo

    2014-07-01

    Microbiological diagnosis is crucial for the appropriate management of implant-associated orthopedic infections (IAOIs). Sonication of biomaterials for microbiological diagnosis has not yet been introduced in routine clinical practice. Aim of this study was to describe the advantages and feasibility of this procedure in the clinical setting. We prospectively studied 56 consecutive patients undergoing revision because of IAOI and compared the sensitivity of sonication of explanted orthopedic implants with standard cultures. Patients were divided into two groups: those with foreign body infection (FBI, 15 patients) and those with prosthetic joint infection (PJI, 41 patients). Clinical, radiological and microbiological features were recorded. In the PJI group the sensitivity of sonication in detecting bacterial growth was higher than conventional culture (77% vs 34.1% respectively, p<0.002), while no difference was observed in the FBI group (85.7% vs 86% respectively, p>0.05). Coagulase-negative Staphylococci accounted for 90% of the bacteria detected by sonication. Moreover, we found that in the PJI group the sensitivity of sonication was not affected by the timing of antibiotic interruption before surgery. Sonication remains an important tool to improve microbiological diagnosis in PJIs, especially in patients who received previous antimicrobial treatment.

  5. Surgeons' Perspectives on Premium Implants in Total Joint Arthroplasty.

    PubMed

    Wasterlain, Amy S; Bello, Ricardo J; Vigdorchik, Jonathan; Schwarzkopf, Ran; Long, William J

    2017-09-01

    Declining total joint arthroplasty reimbursement and rising implant prices have led many hospitals to restrict access to newer, more expensive total joint arthroplasty implants. The authors sought to understand arthroplasty surgeons' perspectives on implants regarding innovation, product launch, costs, and cost-containment strategies including surgeon gain-sharing and patient cost-sharing. Members of the International Congress for Joint Reconstruction were surveyed regarding attitudes about implant technology and costs. Descriptive and univariate analyses were performed. A total of 126 surgeons responded from all 5 regions of the United States. Although 76.9% believed new products advance technology in orthopedics, most (66.7%) supported informing patients that new implants lack long-term clinical data and restricting new implants to a small number of investigators prior to widespread market launch. The survey revealed that 66.7% would forgo gain-sharing incentives in exchange for more freedom to choose implants. Further, 76.9% believed that patients should be allowed to pay incremental costs for "premium" implants. Surgeons who believed that premium products advance orthopedic technology were more willing to forgo gain-sharing (P=.040). Surgeons with higher surgical volume (P=.007), those who believed implant companies should be allowed to charge more for new technology (P<.001), and those who supported discussing costs with patients (P=.004) were more supportive of patient cost-sharing. Most arthroplasty surgeons believe technological innovation advances the field but support discussing the "unproven" nature of new implants with patients. Many surgeons support alternative payment models permitting surgeons and patients to retain implant selection autonomy. Most respondents prioritized patient beneficence and surgeon autonomy above personal financial gain. [Orthopedics. 2017; 40(5):e825-e830.]. Copyright 2017, SLACK Incorporated.

  6. [Orthopedic surgical implants and allergies. Joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)].

    PubMed

    Thomas, P; Schuh, A; Ring, J; Thomsen, M

    2008-03-01

    Materials used in osteosynthesis or artificial joint replacement are usually well tolerated. Complaints after such operations are mostly related to infection or mechanical problems but may also be caused by allergic reactions. The latter encompass skin changes, e.g., eczema, delayed wound/bone healing, recurrent effusion, pain, or implant loosening. In contrast to the high incidence of cutaneous metal contact allergy, allergies associated with implants are a rare condition. However, epidemiological data on the incidence of implant-related allergic reactions are still missing. Typical elicitors are nickel, chromium, cobalt, and constituents of bone cement (acrylates und additives such as gentamicin or benzoyl peroxide). After exclusion of the most common differential diagnoses, allergy diagnostic procedures are primarily based on patch tests including a metal and bone cement component series. Additional analysis of periimplant tissue is recommended. However, further studies are necessary to show the significance of the histologic findings and the role of the lymphocyte transformation test (LTT). Which combinations of factors will induce allergic sensitization to implants or trigger periimplant allergic reactions in the case of preexisting cutaneous metal allergy is still unknown. Titanium-based osteosynthesis materials are recommended for metal allergic patients. In elective hip replacements, a ceramic/polyethylene (PE) articulation should be used, and in knee replacements "alternative materials". If a regular, potentially applicable CoCr/PE articulation is preferred, the patient must be well informed and must give his/her written consent.

  7. Hydroxyapatite-nanotube composites and coatings for orthopedic applications

    NASA Astrophysics Data System (ADS)

    Lahiri, Debrupa

    Hydroxyapatite (HA) has received wide attention in orthopedics, due to its biocompatibility and osseointegration ability. Despite these advantages, the brittle nature and low fracture toughness of HA often results in rapid wear and premature fracture of implant. Hence, there is a need to improve the fracture toughness and wear resistance of HA without compromising its biocompatibility. The aim of the current research is to explore the potential of nanotubes as reinforcement to HA for orthopedic implants. HA- 4 wt.% carbon nanotube (CNT) composites and coatings are synthesized by spark plasma sintering and plasma spraying respectively, and investigated for their mechanical, tribological and biological behavior. CNT reinforcement improves the fracture toughness (>90%) and wear resistance (>66%) of HA for coating and free standing composites. CNTs have demonstrated a positive influence on the proliferation, differentiation and matrix mineralization activities of osteoblasts, during in-vitro biocompatibility studies. In-vivo exposure of HA-CNT coated titanium implant in animal model (rat) shows excellent histocompatibility and neobone integration on the implant surface. The improved osseointegration due to presence of CNTs in HA is quantified by the adhesion strength measurement of single osteoblast using nano-scratch technique. Considering the ongoing debate about cytotoxicity of CNTs in the literature, the present study also suggests boron nitride nanotube (BNNT) as an alternative reinforcement. BNNT with the similar elastic modulus and strength as CNT, were added to HA. The resulting composite having 4 wt.% BNNTs improved the fracture toughness (˜85%) and wear resistance (˜75%) of HA in the similar range as HA-CNT composites. BNNTs were found to be non-cytotoxic for osteoblasts and macrophages. In-vitro evaluation shows positive role of BNNT in osteoblast proliferation and viability. Apatite formability of BNNT surface in ˜4 days establishes its osseointegration

  8. Occupational injuries among pediatric orthopedic surgeons

    PubMed Central

    Alsiddiky, Abdulmonem M.; Alatassi, Raheef; Altamimi, Saad M.; Alqarni, Mahdi M.; Alfayez, Saud M.

    2017-01-01

    Abstract In this cross-sectional study, we surveyed all pediatric orthopedic surgeons in Saudi Arabia using an anonymous electronic questionnaire composed of 23 items to identify the rate of occupational injuries and obtain other relevant information. Thirty-nine participants completed the questionnaire (response rate: 83%). Participants who sustained occupational injuries throughout their careers represented 82.5%. The most injured areas were the hands, eyes, and back by 54.5%, 24.2%, and 15.2%, respectively. Approximately 11.1% were injured while operating on infected patients. Approximately 30.3% reported their injuries to their institution. We concluded that the rate of occupational injuries among pediatric orthopedic surgeons is very high and underreported. PMID:28640103

  9. Glycopeptides versus β-lactams for the prevention of surgical site infections in cardiovascular and orthopedic surgery: a meta-analysis.

    PubMed

    Saleh, Anas; Khanna, Ashish; Chagin, Kevin M; Klika, Alison K; Johnston, Douglas; Barsoum, Wael K

    2015-01-01

    To compare the efficacy of glycopeptides and β-lactams in preventing surgical site infections (SSIs) in cardiac, vascular, and orthopedic surgery. The cost-effectiveness of switching from β-lactams to glycopeptides for preoperative antibiotic prophylaxis has been controversial. β-Lactams are generally recommended in clean surgical procedures, but they are ineffective against resistant gram-positive bacteria. PubMed, International Pharmaceuticals Abstracts, Scopus, and Cochrane were searched for randomized clinical trials comparing glycopeptides and β-lactams for prophylaxis in adults undergoing cardiac, vascular, or orthopedic surgery. Abstracts and conference proceedings were included. Two independent reviewers performed study selection, data extraction, and assessment of risk of bias. Fourteen studies with a total of 8952 patients were analyzed. No difference was detected in overall SSIs between antibiotic types. However, compared with β-lactams, glycopeptides reduced the risk of resistant staphylococcal SSIs by 48% (relative risk, 0.52; 95% confidence interval, 0.29-0.93; P = 0.03) and enterococcal SSIs by 64% (relative risk, 0.36; 95% confidence interval, 0.16-0.80; P = 0.01), but increased respiratory tract infections by 54% (relative risk, 1.54; 95% confidence interval, 1.19-2.01; P ≤ 0.01). Subgroup analysis of cardiac procedures showed superiority of β-lactams in preventing superficial and deep chest SSIs, susceptible staphylococcal SSIs, and respiratory tract infections. Glycopeptides reduce the risk of resistant staphylococcal SSIs and enterococcal SSIs, but increase the risk of respiratory tract infections. Additional high-quality randomized clinical trials are needed as these results are limited by high risk of bias.

  10. Enhancing osseointegration of orthopedic implants with titania nanotube surfaces

    NASA Astrophysics Data System (ADS)

    Baker, Erin A.

    Introduction: As joint arthroplasty surgical procedures increase annually, the development of new strategies, including novel materials and surface modifications, to attain solid bone-implant fixation are needed to increase implant terms of service. In this study, we evaluate two morphologies of titania nanotubes in both in vitro and in vivo experiments to quantify osseointegrative potential and material-level biocompatibility. Materials and Methods: Samples were prepared via an electrochemical etching process. Two different titania nanotube (TiNT) morphologies were produced, Aligned and Trabecular. For the in vitro experiment, Sprague Dawley (SD) rat marrow-derived bone marrow cells (BMC) were seeded on samples. Alkaline phosphatase (ALP) activity, osteocalcin (OC) expression, expression of relevant genes as well as cell attachment and morphology were assessed. In the first in vivo experiment, Kirschner wires were implanted unilaterally into SD rat femora with a TiNT-etched or unmodified (Control) implant. General health assessments and weekly body weights were recorded. At a 12-week endpoint, hematologic, systemic metal ion, and histologic analyses were performed. For the second in vivo experiment, Kirschner wires were implanted bilaterally into SD rat femora, with a TiNT-etched implant in one femora and unmodified (Control) implant as an internal control. At 4- and 12-week endpoints, femora were assessed via biomechanics, undecalcified histology, micro-computed tomography (muCT), and backscattered electron imaging (BEI) to characterize de novo bone formation. Results: In vitro experiments demonstrated BMC attachment and differentiation into osteoblasts as well as greater ALP activity, OC expression, total cell counts, and gene expression (of Col1a1, IGF-1, and osteonectin) on TiNT surfaces versus Controls. Cells on TiNT-etched substrates were smaller in diameter and more eccentric than Controls. In the first in vivo experiment, there were significant differences

  11. From the risk analysis to the development of interventions and training for the prevention and control of healthcare associated infections. The experience of G. Pini Orthopedic Institute.

    PubMed

    Navone, P; Conti, C; Domeniconi, G; Nobile, M

    2015-01-01

    Health-care associated infections (HAIs) represents a phenomenon of central importance all over Europe. Every year 4,5 millions cases are detected in European Union, with 37.000 related deaths. Surgical-site infections (SSIs) are one of the most common HAIs, that are associated with an increased length of stay, re-operation rate, intensive care admissions rate, and higher mortality rate. G. Pini Orthopedics Institute implemented in the last two years a multimodal strategy for controlling and preventing HAIs, in particular for SSIs. This paper describes the prevention's strategies adopted for prevention of HAIs, at G. Pini Orthopedic Institute. Our findings show that application of a multi modal promotion strategy was associated with an improvement in HAI prevention.

  12. Early diagnosis of orthopedic implant failure using macromolecular imaging agents.

    PubMed

    Ren, Ke; Dusad, Anand; Zhang, Yijia; Purdue, P Edward; Fehringer, Edward V; Garvin, Kevin L; Goldring, Steven R; Wang, Dong

    2014-08-01

    To develop and evaluate diagnostic tools for early detection of wear particle-induced orthopaedic implant loosening. N-(2-Hydroxypropyl)methacrylamide (HPMA) copolymer was tagged with a near infrared dye and used to detect the inflammation induced by polymethylmethacrylate (PMMA) particles in a murine peri-implant osteolysis model. It was established by inserting an implant into the distal femur and challenging with routine PMMA particles infusion. The osteolysis was evaluated by micro-CT and histological analysis at different time points. Significant peri-implant osteolysis was found 3-month post PMMA particle challenge by micro-CT and histological analysis. At 1-month post challenge, when there was no significant peri-implant bone loss, the HPMA copolymer-near infrared dye conjugate was found to specifically target the femur with PMMA particles deposition, but not the contralateral control femur with phosphate buffered saline (PBS) infusion. The results from this study demonstrate the feasibility of utilizing the macromolecular diagnostic agent to detect particle-induced peri-implant inflammation prior to the development of detectable osteolysis. Recognition of this early pathological event would provide the window of opportunity for prevention of peri-implant osteolysis and subsequent orthopaedic implant failure.

  13. The implant infection paradox: why do some succeed when others fail? Opinion and discussion paper.

    PubMed

    Yue, C; Zhao, B; Ren, Y; Kuijer, R; van der Mei, H C; Busscher, H J; Rochford, E T J

    2015-06-05

    Biomaterial-implants are frequently used to restore function and form of human anatomy. However, the presence of implanted biomaterials dramatically elevates infection risk. Paradoxically, dental-implants placed in a bacteria-laden milieu experience moderate failure-rates, due to infection (0.0-1.1%), similar to the ones of joint-arthroplasties placed in a near-sterile environment (0.1-1.3%). Transcutaneous bone-fixation pins breach the immune-barrier of the epidermis, exposing underlying sterile-tissue to an unsterile external environment. In contrast to dental-implants, also placed in a highly unsterile environment, these pins give rise to relatively high infection-associated failure-rates of up to 23.0%. Herein, we attempt to identify causes as to why dental-implants so often succeed, where others fail. The major part of all implants considered are metal-made, with similar surface-finishes. Material choice was therefore discarded as underlying the paradox. Antimicrobial activity of saliva has also been suggested as a cause for the success of dental-implants, but was discarded because saliva is the implant-site-fluid from which viable bacteria adhere. Crevicular fluid was discarded as it is largely analogous to serum. Instead, we attribute the relative success of dental-implants to (1) ability of oral tissues to heal rapidly in the continuous presence of commensal bacteria and opportunistic pathogens, and (2) tolerance of the oral immune-system. Inability of local tissue to adhere, spread and grow in presence of bacteria and an intolerant immune-system are identified as the likely main causes explaining the susceptibility of other implants to infection-associated failure. In conclusion, it is the authors' belief that new anti-infection strategies for a wide range of biomaterial-implants may be derived from the relative success of dental-implants.

  14. Cardiovascular implantable electronic device infections in left ventricular assist device recipients.

    PubMed

    Riaz, Talha; Nienaber, Juhsien J C; Baddour, Larry M; Walker, Randall C; Park, Soon J; Sohail, Muhammad Rizwan

    2014-02-01

    Most patients with left ventricular assist devices (LVADs) have concomitant cardiovascular implantable electronic devices (CIEDs). However, clinical presentation and outcome of CIED infection in the setting of LVAD has not been previously described. We retrospectively reviewed 247 patients who underwent LVAD implantation at Mayo Clinic campuses in Minnesota, Arizona, and Florida, from January 2005 to December 2011. Demographic and clinical data of patients who met criteria for CIED infection were extracted. Of 247 patients with LVADs, 215 (87%) had CIED at the time of LVAD implantation and six (2.8%) subsequently developed CIED infections. Three patients developed CIED lead-related endocarditis and the other three had pocket infection. All three instances of CIED pocket infection were preceded by device generator exchange, whereas all three patients with CIED lead-related endocarditis had prior LVAD-related infections. Causative pathogens included Pseudomonas aeruginos (1), coagulase-negative staphylococci (2), methicillin-resistant Staphylococcus aureus (1), a gram-positive bacillus (1), and culture negative (2). All patients underwent complete CIED removal along with antimicrobial therapy. The three patients with CIED lead-related endocarditis and prior LVAD infections received chronic suppressive antibiotic therapy, and one patient had LVAD exchange. All but one remained alive at the last follow-up with a median duration of 15 months (7-46 months) from the time of CIED infection. Patients who are receiving LVAD therapy and develop CIED infection should be managed with complete CIED removal. Chronic suppressive antibiotic therapy is warranted in cases that have concomitant LVAD infection. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  15. Traffic flow in the operating room: an explorative and descriptive study on air quality during orthopedic trauma implant surgery.

    PubMed

    Andersson, Annette Erichsen; Bergh, Ingrid; Karlsson, Jón; Eriksson, Bengt I; Nilsson, Kerstin

    2012-10-01

    Understanding the protective potential of operating room (OR) ventilation under different conditions is crucial to optimizing the surgical environment. This study investigated the air quality, expressed as colony-forming units (CFU)/m(3), during orthopedic trauma surgery in a displacement-ventilated OR; explored how traffic flow and the number of persons present in the OR affects the air contamination rate in the vicinity of surgical wounds; and identified reasons for door openings in the OR. Data collection, consisting of active air sampling and observations, was performed during 30 orthopedic procedures. In 52 of the 91 air samples collected (57%), the CFU/m(3) values exceeded the recommended level of <10 CFU/m(3). In addition, the data showed a strongly positive correlation between the total CFU/m(3) per operation and total traffic flow per operation (r = 0.74; P = .001; n = 24), after controlling for duration of surgery. A weaker, yet still positive correlation between CFU/m(3) and the number of persons present in the OR (r = 0.22; P = .04; n = 82) was also found. Traffic flow, number of persons present, and duration of surgery explained 68% of the variance in total CFU/m(3) (P = .001). Traffic flow has a strong negative impact on the OR environment. The results of this study support interventions aimed at preventing surgical site infections by reducing traffic flow in the OR. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  16. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    PubMed

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap

  17. Incidence and clinical implication of nosocomial infections associated with implantable biomaterials – catheters, ventilator-associated pneumonia, urinary tract infections

    PubMed Central

    Guggenbichler, Josef Peter; Assadian, Ojan; Boeswald, Michael; Kramer, Axel

    2012-01-01

    Health care associated infections, the fourth leading cause of disease in industrialised countries, are a major health issue. One part of this condition is based on the increasing insertion and implantation of prosthetic medical devices, since presence of a foreign body significantly reduces the number of bacteria required to produce infection. The most significant hospital-acquired infections, based on frequency and potential severity, are those related to procedures e.g. surgical site infections and medical devices, including urinary tract infection in catheterized patients, pneumonia in patients intubated on a ventilator and bacteraemia related to intravascular catheter use. At least half of all cases of nosocomial infections are associated with medical devices. Modern medical and surgical practices have increasingly utilized implantable medical devices of various kinds. Such devices may be utilized only short-time or intermittently, for months, years or permanently. They improve the therapeutic outcome, save human lives and greatly enhance the quality of life of these patients. However, plastic devices are easily colonized with bacteria and fungi, able to be colonized by microorganisms at a rate of up to 0.5 cm per hour. A thick biofilm is formed within 24 hours on the entire surface of these plastic devices once inoculated even with a small initial number of bacteria. The aim of the present work is to review the current literature on causes, frequency and preventive measures against infections associated with intravascular devices, catheter-related urinary tract infection, ventilator-associated infection, and infections of other implantable medical devices. Raising awareness for infection associated with implanted medical devices, teaching and training skills of staff, and establishment of surveillance systems monitoring device-related infection seem to be the principal strategies used to achieve reduction and prevention of such infections. The intelligent use

  18. Surface evaluation of orthopedic hip implants marketed in Brazil

    NASA Astrophysics Data System (ADS)

    Souza, M. M.; Trommer, R. M.; Maru, M. M.; Roesler, C. R. M.; Barros, W. S.; Dutra, M. S.

    2016-07-01

    One of the factors that contribute to the quality of total hip prostheses is the degree of accuracy in the manufacturing of the joint surfaces. The dimensional control of joint components is important because of its direct influence on the durability and, consequently, in the patients’ life quality. This work presents studies on the form and roughness of orthopedic hip prostheses marketed in Brazil. The results provide data for quality control of the surfaces of the femoral heads and acetabular components of hip prostheses and indicate the need of improvement in the procedures used to this control.

  19. Managing orthopedics and neurosciences costs through standard treatment protocols.

    PubMed

    McGinnity, E S; Pluth, T E

    1994-06-01

    High-cost, high-volume specialty programs such as orthopedics and neurosciences find themselves in a position of evaluating the costs and in some cases the appropriateness of medical practices in response to payer scrutiny and provider selection processes. Orthopedics and neurosciences programs are at a stage of development analogous to that of cardiovascular care several years ago. Many of the same trends have come into play, such as payer "carve-outs" for orthopedic services, payer selection of centers of excellence based on cost and quality, reduction of Medicare reimbursement, greater use of high-cost technology, the decline of profitability due to "older, sicker, and tougher" patients, and the recent emergence of national orthopedic specialty networks oriented to national contracts for care. In an era in which payers demand value on both sides of the cost-plus-quality equation, programs are challenged to maximize the return on a patient population rife with "no-win" situations. In the orthopedic service line these include a high proportion of Medicare patients and chronic conditions such as workers' compensation medical back cases or repetitive motion injuries, which can be elusive to diagnose and expensive to treat. Many hospitals continue to lose money on joint replacement surgeries, the largest-volume orthopedic inpatient service, primarily because of the high Medicare population and the cost of implants. Neuroservices, while still relatively well reimbursed, face a rising proportion of Medicare payments as patients live longer and develop chronic, degenerative conditions. Inpatient days are decreasing due to payer pressures to limit hospital stays and to shift inpatient care to outpatient services. Some hospitals "have lost interest in (the orthopedic) service line during the last five years because of recent trends in orthopedic-related inpatient volume and payment." But by managing costs strategically, both the neurosciences and orthopedics service lines

  20. Transparency to Reduce Surgical Implant Waste.

    PubMed

    Pfefferle, Kiel J; Dilisio, Matthew F; Patti, Brianna; Fening, Stephen D; Junko, Jeffrey T

    2015-06-01

    Rising health care costs and emphasis on value have placed the onus of reducing healthcare costs on the surgeon. Financial data from 3,973 hip, knee, and shoulder arthroplasties performed at a physician owned orthopedic hospital was retrospectively reviewed over a two-year period. A wasted implant financial report was posted starting the second year of the study. Each surgeon's performance could be identified by his peers. After posting of the financial report, 1.11% of all hip and knee arthroplasty cases had a waste event compared to 1.50% during the control year. Shoulder arthroplasty waste events occurred twice as often than that observed in hip and knee arthroplasty during the study period. A decrease in waste events was observed but was not statistically significant (p = 0.30). Posting a non-blinded wasted implant data sheet was associated with a reduction in the number of wasted orthopedic surgical implants in this series, although the reduction was not statistically significant.

  1. In Vitro and in Vivo Studies on Biomedical Magnesium Low-Alloying with Elements Gadolinium and Zinc for Orthopedic Implant Applications.

    PubMed

    Bian, Dong; Deng, Jiuxu; Li, Nan; Chu, Xiao; Liu, Yang; Li, Wenting; Cai, Hong; Xiu, Peng; Zhang, Yu; Guan, Zhenpeng; Zheng, Yufeng; Kou, Yuhui; Jiang, Baoguo; Chen, Rongshi

    2018-02-07

    Ternary magnesium alloys with low combined addition of elements gadolinium and zinc were developed in the present work, with their microstructures, mechanical properties, in vitro degradation behaviors, and cytotoxicity being systematically studied. Furthermore, the Mg-1.8Zn-0.2Gd alloy, with the best in vitro performance, was implanted into Sprague Dawley rats to examine its in vivo degradation performance for up to 6 months. It was found that Mg-1.8Zn-0.2Gd, composed of a single α-Mg phase, owned excellent strength and toughness that were comparable to the CE marked MAGNEZIX, the mischmetal added Mg alloy. Owing to the uniform single-phased microstructure, the degradation rate of this alloy was around 0.12 mm/y measured by electrochemical testing, which was comparable to high purity magnesium. Moreover, the Mg-1.8Zn-0.2Gd alloy exhibited no cytotoxicity to L929, MG63, and VSMC cells. In vivo degradation characterized by micro-computed tomography revealed that the Mg-1.8Zn-0.2Gd implant could maintain structural integrity in the first 2 months, and serious degradation could be observed after 6 months. A remarkable 100% survival rate of experimental animals was observed with no negative effects on bone tissues. The implant and the surrounding bone were well integrated within 2 months, implying good biocompatibility and osteoconductivity of the experimental alloy. On the basis of the above findings, the feasibility of Mg-Zn-Gd alloys for use as orthopedic implants was systematically discussed. This study provides a new strategy for development of high-performance Mg-rare earth (RE)-based alloys with superior mechanical properties and corrosion resistance while effectively avoiding the possible standing toxic effect of RE elements.

  2. Preparation, characterization, and in vitro osteoblast functions of a nano-hydroxyapatite/polyetheretherketone biocomposite as orthopedic implant material

    PubMed Central

    Ma, Rui; Tang, Songchao; Tan, Honglue; Lin, Wentao; Wang, Yugang; Wei, Jie; Zhao, Liming; Tang, Tingting

    2014-01-01

    A bioactive composite was prepared by incorporating 40 wt% nano-hydroxyapatite (nHA) into polyetheretherketone (PEEK) through a process of compounding, injection, and molding. The mechanical and surface properties of the nHA/PEEK composite were characterized, and the in vitro osteoblast functions in the composite were investigated. The mechanical properties (elastic modulus and compressive strength) of the nHA/PEEK composite increased significantly, while the tensile strength decreased slightly as compared with PEEK. Further, the addition of nHA into PEEK increased the surface roughness and hydrophilicity of the nHA/PEEK composite. In cell tests, compared with PEEK and ultra-high-molecular-weight polyethylene, it was found that the nHA/PEEK composite could promote the functions of MC3T3-E1 cells, including cell attachment, spreading, proliferation, alkaline phosphatase activity, calcium nodule formation, and expression of osteogenic differentiation-related genes. Incorporation of nHA into PEEK greatly improved the bioperformance of PEEK. The nHA/PEEK composite might be a promising orthopedic implant material. PMID:25170265

  3. Defining a glycated haemoglobin (HbA1c) level that predicts increased risk of penile implant infection.

    PubMed

    Habous, Mohamad; Tal, Raanan; Tealab, Alaa; Soliman, Tarek; Nassar, Mohammed; Mekawi, Zenhom; Mahmoud, Saad; Abdelwahab, Osama; Elkhouly, Mohamed; Kamr, Hatem; Remeah, Abdallah; Binsaleh, Saleh; Ralph, David; Mulhall, John

    2018-02-01

    To re-evaluate the role of diabetes mellitus (DM) as a risk factor for penile implant infection by exploring the association between glycated haemoglobin (HbA1c) levels and penile implant infection rates and to define a threshold value that predicts implant infection. We conducted a multicentre prospective study including all patients undergoing penile implant surgery between 2009 and 2015. Preoperative, perioperative and postoperative management were identical for the entire cohort. Univariate analysis was performed to define predictors of implant infection. The HbA1c levels were analysed as continuous variables and sequential analysis was conducted using 0.5% increments to define a threshold level predicting implant infection. Multivariable analysis was performed with the following factors entered in the model: DM, HbA1C level, patient age, implant type, number of vascular risk factors (VRFs), presence of Peyronie's disease (PD), body mass index (BMI), and surgeon volume. A receiver operating characteristic (ROC) curve was generated to define the optimal HbA1C threshold for infection prediction. In all, 902 implant procedures were performed over the study period. The mean patient age was 56.6 years. The mean HbA1c level was 8.0%, with 81% of men having a HbA1c level of >6%. In all, 685 (76%) implants were malleable and 217 (24%) were inflatable devices; 302 (33.5%) patients also had a diagnosis of PD. The overall infection rate was 8.9% (80/902). Patients who had implant infection had significantly higher mean HbA1c levels, 9.5% vs 7.8% (P < 0.001). Grouping the cases by HbA1c level, we found infection rates were: 1.3% with HbA1c level of <6.5%, 1.5% for 6.5-7.5%, 6.5% for 7.6-8.5%, 14.7% for 8.6-9.5%, 22.4% for >9.5% (P < 0.001). Patient age, implant type, and number of VRFs were not predictive. Predictors defined on multivariable analysis were: PD, high BMI, and high HbA1c level, whilst a high-volume surgeon had a protective effect and was associated with a

  4. Prolonged incubation time does not increase sensitivity for the diagnosis of implant-related infection using samples prepared by sonication of the implants.

    PubMed

    Esteban, J; Alvarez-Alvarez, B; Blanco, A; Fernández-Roblas, R; Gadea, I; Garcia-Cañete, J; Sandoval, E; Valdazo, M

    2013-07-01

    We have designed a prospective study to evaluate the usefulness of prolonged incubation of cultures from sonicated orthopaedic implants. During the study period 124 implants from 113 patients were processed (22 osteosynthetic implants, 46 hip prostheses, 54 knee prostheses, and two shoulder prostheses). Of these, 70 patients had clinical infection; 32 had received antibiotics at least seven days before removal of the implant. A total of 54 patients had sonicated samples that produced positive cultures (including four patients without infection). All of them were positive in the first seven days of incubation. No differences were found regarding previous antibiotic treatment when analysing colony counts or days of incubation in the case of a positive result. In our experience, extending incubation of the samples to 14 days does not add more positive results for sonicated orthopaedic implants (hip and knee prosthesis and osteosynthesis implants) compared with a conventional seven-day incubation period.

  5. Detection of resistance to linezolid in Staphylococcus aureus infecting orthopedic patients.

    PubMed

    Thool, Vaishali U; Bhoosreddy, Girish L; Wadher, Bharat J

    2012-01-01

    In today's medical scenario, the human race is battling the most intelligent enemy who has unending alternatives to combat with the potent elements they have produced against it. To study the resistance to linezolid among Staphylococcus aureus isolated from pus samples of orthopedic patients. Pus samples were collected from dirty wounds of orthopedic patients undergoing long antimicrobial treatment programs. The sampling period was from July 2010 to June 2011. The samples were collected from different orthopedic hospitals of Nagpur (central India) representing a mixed sample of patients. One hundred pus samples were screened for S. aureus, by growth on mannitol salt agar (MSA), Baird-Parker agar (BPA), deoxyribonuclease test, tube coagulase test, and HiStaph latex agglutination test. Fifty-one S. aureus isolates were obtained which were further subjected to antimicrobial susceptibility testing by Kirby-Bauer disc diffusion method (DDM). Minimal inhibitory concentrations (MICs) were determined by an automated system, the VITEK 2 system. Also, Ezy MIC strip method was carried out in accordance with Clinical and Laboratory Standards Institute (CLSI) guidelines. Twelve linezolid-resistant S. aureus (LRSA) isolates were recovered from 51 S. aureus cultures tested for susceptibility to linezolid using the DDM, VITEK 2 system, and Ezy MIC strip method. The emergence of resistance suggests nosocomial spread and abuse of antibiotic.

  6. Current methods for molecular epidemiology studies of implant infections.

    PubMed

    Campoccia, Davide; Montanaro, Lucio; Arciola, Carla Renata

    2009-09-01

    Over the last few decades, the number of surgical procedures involving prosthetic materials has greatly multiplied, along with the rising medical and economic impact of implant-associated infections. The need to appropriately counteract and deal with this phenomenon has led to growing efforts to elucidate the etiology, pathogenesis and epidemiology of these types of infections, characterized by opportunistic pathogens. Molecular epidemiology studies have progressively emerged as a leading multitask tool to identify and fingerprint bacterial strains, unveil the complex clonal nature of important pathogens, detect outbreak events, track the origin of the infections, assess the clinical significance of individual strain types, survey their distribution, recognize associations of strain types with specific virulence determinants and/or pathological conditions, assess the role played by the specific components of the virulon, and reveal the phylogeny and the mechanisms through which new strain types have emerged. Despite the many advances that have been made thanks to these flourishing new approaches to molecular epidemiology, a number of critical aspects remain challenging. In this paper, we briefly discuss the current limitations and possible developments of molecular epidemiology methods in the investigation and surveillance of implant infections.

  7. Association of Airborne Microorganisms in the Operating Room With Implant Infections: A Randomized Controlled Trial.

    PubMed

    Darouiche, Rabih O; Green, David M; Harrington, Melvyn A; Ehni, Bruce L; Kougias, Panagiotis; Bechara, Carlos F; O'Connor, Daniel P

    2017-01-01

    OBJECTIVE To evaluate the association of airborne colony-forming units (CFU) at incision sites during implantation of prostheses with the incidence of either incisional or prosthesis-related surgical site infections. DESIGN Randomized, controlled trial. SETTING Primary, public institution. PATIENTS Three hundred patients undergoing total hip arthroplasty, instrumented spinal procedures, or vascular bypass graft implantation. METHODS Patients were randomly assigned in a 1:1 ratio to either the intervention group or the control group. A novel device (Air Barrier System), previously shown to reduce airborne CFU at incision sites, was utilized in the intervention group. Procedures assigned to the control group were performed without the device, under routine operating room atmospheric conditions. Patients were followed up for 12 months to determine whether airborne CFU levels at the incision sites predicted the incidence of incisional or prosthesis-related infection. RESULTS Data were available for 294 patients, 148 in the intervention group and 146 in the control group. CFU density at the incision site was significantly lower in the intervention group than in the control group (P<.001). The density of airborne CFU at the incision site during the procedures was significantly related to the incidence of implant infection (P=.021). Airborne CFU densities were 4 times greater in procedures with implant infection versus no implant infection. All 4 of the observed prosthesis infections occurred in the control group. CONCLUSION Reduction of airborne CFU specifically at the incision site during operations may be an effective strategy to reduce prosthesis-related infections. clinicaltrials.gov Identifier: NCT01610271 Infect Control Hosp Epidemiol 2016;1-8.

  8. Diagnosis and management of the infected total joint arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuckler, J.M.; Star, A.M.; Alavi, A.

    The preoperative diagnosis of the infected orthopedic implant is complicated by lack of a single precise test to forewarn patient and surgeon of the presence of microorganisms. Given the overall limitation of accuracy of preoperative diagnosis to approximately 80% when 111In scanning, preoperative aspiration, and ESR are considered, it would seem prudent to approach each revision surgery with the possibility in mind of subclinical sepsis as the cause for failure of the implant. The essentials of surgical technique including thorough debridement of the wound and removal of all existing foreign bodies, especially including PMMA bone cement, are critical to minimizingmore » the risk for occurrence or persistence of sepsis. Although the use of antibiotic impregnated bone cement may enhance the treatment of orthopedic sepsis, the data available to date lead to the conclusion that two-stage revision surgery in the face of known sepsis remains the cornerstone of surgical therapy for the infected implant, along with aggressive and rational antibiotic treatment. The surgeon is offered the following guidelines in the management of the septic total hip arthroplasty. 1. Preoperative evaluation including ESR, 111In WBC scan, and aspiration for culture and sensitivity (fluoroscopically guided for the hip) will produce on average approximately 80% accuracy. 2. Intraoperative cultures at the time of revision surgery should be obtained prior to administration of systemic antibiotics; three tissue specimens (hip capsule, femoral membrane, acetabular membrane) should be submitted for culture and sensitivity determination. 3. Careful debridement of the surgical site of granulation tissue and all foreign bodies (e.g., PMMA) should be performed within the limits of patient safety to maximize the likelihood of success. 37 refs.« less

  9. Evaluation of MR issues for the latest standard brands of orthopedic metal implants: plates and screws.

    PubMed

    Zou, Yue-Fen; Chu, Bin; Wang, Chuan-Bing; Hu, Zhi-Yi

    2015-03-01

    The study was performed to evaluate magnetic resonance (MR) issues for the latest standard brands of plates and screws used in orthopedic surgery at a 1.5-T MR system, including the safety and metallic artifacts. The plates and screws (made of titanium alloy and stainless steel materials, according to the latest standard brands) were assessed for displacement in degrees, MRI-related heating and artifacts at a 1.5-T MR system. The displacement in degrees of the plates and screws was evaluated on an angel-measurement instrument at the entrance of the MR scanner. The MRI-related heating was assessed on a swine leg fixed with a plate by using a "worst-case" pulse sequence. A rectangular water phantom was designed to evaluate metallic artifacts of a screw on different sequences (T1/T2-weighted FSE, STIR, T2-FSE fat saturation, GRE, DWI) and then artifacts were evaluated on T2-weighted FSE sequence by modifying the scanning parameters including field of view (FOV), echo train length (ETL) and bandwidth to identify the influence of parameters on metallic artifacts. 15 volunteers with internal vertebral fixation (titanium alloy materials) were scanned with MR using axial and sagittal T2-FSE, sagittal T2-FSE fat suppression and STIR with conventional and optimized parameters, respectively. Then all images were graded by two experienced radiologists having the experience of more than 7 years under double-blind studies that is neither of them knew which was conventional parameter group and optimized parameter group. The average deflection angle of titanium alloy and stainless steel implants were 4.3° and 7.7°, respectively, (less than 45°) which indicated that the magnetically induced force was less than the weight of the object. The deflection angle of the titanium alloy implants was less than the stainless steel one (t=9.69, P<0.001). The average temperature changes of titanium alloy before and after the scan was 0.48°C and stainless steel implants was 0.74

  10. Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature.

    PubMed

    Al-Ghamdi, Bandar; Widaa, Hassan El; Shahid, Maie Al; Aladmawi, Mohammed; Alotaibi, Jawaher; Sanei, Aly Al; Halim, Magid

    2016-08-24

    Infection of cardiac implantable electronic devices is a serious cardiovascular disease and it is associated with a high mortality. Mycobacterium species may rarely cause cardiac implantable electronic devices infection. We are reporting a case of miliary tuberculosis in an Arab patient with dilated cardiomyopathy and a cardiac resynchronization therapy-defibrillator device that was complicated with infection of his cardiac resynchronization therapy-defibrillator device. To our knowledge, this is the third case in the literature with such a presentation and all patients died during the course of treatment. This underscores the importance of early diagnosis and management. We also performed a literature review of reported cases of cardiac implantable electronic devices infection related to Mycobacterium species. Cardiac implantable electronic devices infection due to Mycobacterium species is an uncommon but a well-known entity. Early diagnosis and prompt management may result in a better outcome.

  11. 3D printed bioceramics for dual antibiotic delivery to treat implant-associated bone infection.

    PubMed

    Inzana, J A; Trombetta, R P; Schwarz, E M; Kates, S L; Awad, H A

    2015-11-04

    Surgical implant-associated bone infections (osteomyelitis) have severe clinical and socioeconomic consequences. Treatment of chronic bone infections often involves antibiotics given systemically and locally to the affected site in poly (methyl methacrylate) (PMMA) bone cement. Given the high antibiotic concentrations required to affect bacteria in biofilm, local delivery is important to achieve high doses at the infection site. PMMA is not suitable to locally-deliver some biofilm-specific antibiotics, including rifampin, due to interference with PMMA polymerisation. To examine the efficacy of localised, combinational antibiotic delivery compared to PMMA standards, we fabricated rifampin- and vancomycin-laden calcium phosphate scaffolds (CPS) by three-dimensional (3D) printing to treat an implant-associated Staphylococcus aureus bone infection in a murine model. All vancomycin- and rifampin-laden CPS treatments significantly reduced the bacterial burden compared with vancomycin-laden PMMA. The bones were bacteria culture negative in 50 % of the mice that received sustained release vancomycin- and rifampin-laden CPS. In contrast, 100 % of the bones treated with vancomycin monotherapy using PMMA or CPS were culture positive. Yet, the monotherapy CPS significantly reduced the bacterial metabolic load following revision compared to PMMA. Biofilm persisted on the fixation hardware, but the infection-induced bone destruction was significantly reduced by local rifampin delivery. These data demonstrate that, despite the challenging implant-retaining infection model, co-delivery of rifampin and vancomycin from 3D printed CPS, which is not possible with PMMA, significantly improved the outcomes of implant-associated osteomyelitis. However, biofilm persistence on the fixation hardware reaffirms the importance of implant exchange or other biofilm eradication strategies to complement local antibiotics.

  12. 3D printed bioceramics for dual antibiotic delivery to treat implant-associated bone infection

    PubMed Central

    Inzana, Jason A.; Trombetta, Ryan P.; Schwarz, Edward M.; Kates, Stephen L.; Awad, Hani A.

    2015-01-01

    Surgical implant-associated bone infections (osteomyelitis) have severe clinical and socioeconomic consequences. Treatment of chronic bone infections often involves antibiotics given systemically and locally to the affected site via poly(methyl methacrylate) (PMMA) bone cement. Given the high antibiotic concentrations required to affect bacteria in biofilm, local delivery is important to achieve high doses at the infection site. PMMA is not suitable to locally deliver some biofilm-specific antibiotics, including rifampin, due to interference with PMMA polymerization. To examine the efficacy of localized, combinational antibiotic delivery compared to PMMA standards, we fabricated rifampin- and vancomycin-laden calcium phosphate scaffolds (CPS) by three-dimensional (3D) printing to treat an implant-associated Staphylococcus aureus bone infection in a murine model. All vancomycin- and rifampin-laden CPS treatments significantly reduced the bacterial burden compared with vancomycin-laden PMMA. The bones were bacteria culture negative in 50% of the mice that received sustained release vancomycin- and rifampin-laden CPS. In contrast, 100% of the bones treated with vancomycin monotherapy via PMMA or CPS were culture positive. Yet, the monotherapy CPS significantly reduced the bacterial metabolic load following revision compared to PMMA. Biofilm persisted on the fixation hardware, but the infection-induced bone destruction was significantly reduced by local rifampin delivery. These data demonstrate that, despite the challenging implant-retaining infection model, co-delivery of rifampin and vancomycin from 3D printed CPS, which is not possible with PMMA, significantly improved the outcomes of implant-associated osteomyelitis. However, biofilm persistence on the fixation hardware reaffirms the importance of implant exchange or other biofilm eradication strategies to complement local antibiotics. PMID:26535494

  13. Wholistic orthopedics: Is this the right way to treat geriatric orthopedic patients?

    PubMed

    Ebnezar, John; Bali, Yogita; John, Rakesh

    2017-01-01

    Geriatric orthopedic problems poses different challenges in their management. Conventional treatment methods like drugs, physiotherapy and surgeries are inadequate. A Geriatric orthopedic patient suffers as a whole and not in isolation. This article highlights the importance of managing geriatric orthopedic patients as a whole and outlines the various steps of wholistic management.

  14. Percutaneous Lead Extraction in Infection of Cardiac Implantable Electronic Devices: a Systematic Review

    PubMed Central

    Menezes Júnior, Antônio da Silva; Magalhães, Thaís Rodrigues; Morais, Alana de Oliveira Alarcão

    2018-01-01

    Introduction In the last two decades, the increased number of implants of cardiac implantable electronic devices has been accompanied by an increase in complications, especially infection. Current recommendations for the appropriate treatment of cardiac implantable electronic devices-related infections consist of prolonged antibiotic therapy associated with complete device extraction. The purpose of this study was to analyze the importance of percutaneous extraction in the treatment of these devices infections. Methods A systematic review search was performed in the PubMed, BVS, Cochrane CENTRAL, CAPES, SciELO and ScienceDirect databases. A total of 1,717 studies were identified and subsequently selected according to the eligibility criteria defined by relevance tests by two authors working independently. Results Sixteen studies, describing a total of 3,354 patients, were selected. Percutaneous extraction was performed in 3,081 patients. The average success rate for the complete percutaneous removal of infected devices was 92.4%. Regarding the procedure, the incidence of major complications was 2.9%, and the incidence of minor complications was 8.4%. The average in-hospital mortality of the patients was 5.4%, and the mortality related to the procedure ranged from 0.4 to 3.6%. The mean mortality was 20% after 6 months and 14% after a one-year follow-up. Conclusion Percutaneous extraction is the main technique for the removal of infected cardiac implantable electronic devices, and it presents low rates of complications and mortality related to the procedure.

  15. Review: emerging developments in the use of bioactive glasses for treating infected prosthetic joints.

    PubMed

    Rahaman, Mohamed N; Bal, B Sonny; Huang, Wenhai

    2014-08-01

    Bacterial contamination of implanted orthopedic prostheses is a serious complication that requires prolonged systemic antibiotic therapy, major surgery to remove infected implants, bone reconstruction, and considerable morbidity. Local delivery of high doses of antibiotics using poly(methyl methacrylate) (PMMA) cement as the carrier, along with systemic antibiotics, is the standard treatment. However, PMMA is not biodegradable, and it can present a surface on which secondary bacterial infection can occur. PMMA spacers used to treat deep implant infections must be removed after resolution of the infection. Alternative carrier materials for antibiotics that could also restore deficient bone are therefore of interest. In this article, the development of bioactive glass-based materials as a delivery system for antibiotics is reviewed. Bioactive glass is osteoconductive, converts to hydroxyapatite, and heals to hard and soft tissues in vivo. Consequently, bioactive glass-based carriers can provide the combined functions of controlled local antibiotic delivery and bone restoration. Recently-developed borate bioactive glasses are of particular interest since they have controllable degradation rates coupled with desirable properties related to osteogenesis and angiogenesis. Such glasses have the potential for providing a new class of biomaterials, as substitutes for PMMA, in the treatment of deep bone infections. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Vitamin E Phosphate Coating Stimulates Bone Deposition in Implant-related Infections in a Rat Model.

    PubMed

    Lovati, Arianna B; Bottagisio, Marta; Maraldi, Susanna; Violatto, Martina B; Bortolin, Monica; De Vecchi, Elena; Bigini, Paolo; Drago, Lorenzo; Romanò, Carlo L

    2018-06-01

    Implant-related infections are associated with impaired bone healing and osseointegration. In vitro antiadhesive and antibacterial properties and in vivo antiinflammatory effects protecting against bone loss of various formulations of vitamin E have been demonstrated in animal models. However, to the best of our knowledge, no in vivo studies have demonstrated the synergistic activity of vitamin E in preventing bacterial adhesion to orthopaedic implants, thus supporting the bone-implant integration. The purpose of this study was to test whether a vitamin E phosphate coating on titanium implants may be able to reduce (1) the bacterial colonization of prosthetic implants and (2) bone resorption and osteomyelitis in a rat model of Staphylococcus aureus-induced implant-related infection. Twelve rats were bilaterally injected in the femurs with S aureus UAMS-1-Xen40 and implanted with uncoated or vitamin E phosphate-coated titanium Kirschner wires without local or systemic antibiotic prophylaxis. Eight rats represented the uninfected control group. A few hours after surgery, two control and three infected animals died as a result of unexpected complications. With the remaining rats, we assessed the presence of bacterial contamination with qualitative bioluminescence imaging and Gram-positive staining and with quantitative bacterial count. Bone changes in terms of resorption and osteomyelitis were quantitatively analyzed through micro-CT (bone mineral density) and semiquantitatively through histologic scoring systems. Six weeks after implantation, we found only a mild decrease in bacterial count in coated versus uncoated implants (Ti versus controls: mean difference [MD], -3.705; 95% confidence interval [CI], -4.416 to -2.994; p < 0.001; TiVE versus controls: MD, -3.063; 95% CI, -3.672 to -2.454; p < 0.001), whereas micro-CT analysis showed a higher bone mineral density at the knee and femoral metaphysis in the vitamin E-treated group compared with uncoated implants (knee

  17. Wholistic orthopedics: Is this the right way to treat geriatric orthopedic patients?

    PubMed Central

    Ebnezar, John; Bali, Yogita; John, Rakesh

    2017-01-01

    Geriatric orthopedic problems poses different challenges in their management. Conventional treatment methods like drugs, physiotherapy and surgeries are inadequate. A Geriatric orthopedic patient suffers as a whole and not in isolation. This article highlights the importance of managing geriatric orthopedic patients as a whole and outlines the various steps of wholistic management. PMID:28149067

  18. Octenidine in combination with polymethylmethacrylate: a new option for preventing infection?

    PubMed

    Weckbach, Sebastian; Möricke, Angelika; Braunwarth, Horst; Goroncy-Bermes, Peter; Bischoff, Mark; Gebhard, Florian

    2012-01-01

    Orthopedic implant infections represent a serious complication for both patient and surgeon. In order to minimize this risk, it has become standard practice in surgery and orthopedics to add antimicrobial substances to the polymethylmethacrylate (PMMA) bone cement. The aim of this study is to find new options for preventing infection by using alternative adjuvants in combination with PMMA. We hypothesized, that Octenidine, after being combined with PMMA, can be released in vitro and an antimicrobial efficacy of discharged Octenidine can be shown. The release of Octenidine from PMMA was assessed in high pressure liquid chromatography of the supernatant. In order to assess the efficacy of Octenidine on Staphylococcus aureus and Pseudomonas aeruginosa in vitro, a nutrient solution for these bacteria was incubated with a defined number of these bacteria (10(6) colony forming units) and cement pellets containing the antiseptic Octenidine for 24 h. After the incubation the number of bacteria in the solution was determined by counting the colony forming units on blood agar plates. Octenidine was shown to be released in a concentration-dependent manner from PMMA in the elution experiment. The experimental procedure using S. aureus demonstrated a bactericidal effect for bone cement containing Octenidine. For P. aeruginosa, bone cement containing 5-8% Octenidine was associated with tenfold reduction in bacterial count. These results suggest that Octenidine is released after combining it with PMMA and reaches working concentrations in vitro. These findings suggest a new and effective alternative for prevention of infection in cemented implants. Further investigations on the biocompatibility of this combination is needed.

  19. Surface modification of implants in long bone.

    PubMed

    Förster, Yvonne; Rentsch, Claudia; Schneiders, Wolfgang; Bernhardt, Ricardo; Simon, Jan C; Worch, Hartmut; Rammelt, Stefan

    2012-01-01

    Coatings of orthopedic implants are investigated to improve the osteoinductive and osteoconductive properties of the implant surfaces and thus to enhance periimplant bone formation. By applying coatings that mimic the extracellular matrix a favorable environment for osteoblasts, osteoclasts and their progenitor cells is provided to promote early and strong fixation of implants. It is known that the early bone ongrowth increases primary implant fixation and reduces the risk of implant failure. This review presents an overview of coating titanium and hydroxyapatite implants with components of the extracellular matrix like collagen type I, chondroitin sulfate and RGD peptide in different small and large animal models. The influence of these components on cells, the inflammation process, new bone formation and bone/implant contact is summarized.

  20. Surface modification of implants in long bone

    PubMed Central

    Förster, Yvonne; Rentsch, Claudia; Schneiders, Wolfgang; Bernhardt, Ricardo; Simon, Jan C.; Worch, Hartmut; Rammelt, Stefan

    2012-01-01

    Coatings of orthopedic implants are investigated to improve the osteoinductive and osteoconductive properties of the implant surfaces and thus to enhance periimplant bone formation. By applying coatings that mimic the extracellular matrix a favorable environment for osteoblasts, osteoclasts and their progenitor cells is provided to promote early and strong fixation of implants. It is known that the early bone ongrowth increases primary implant fixation and reduces the risk of implant failure. This review presents an overview of coating titanium and hydroxyapatite implants with components of the extracellular matrix like collagen type I, chondroitin sulfate and RGD peptide in different small and large animal models. The influence of these components on cells, the inflammation process, new bone formation and bone/implant contact is summarized. PMID:23507866

  1. Antibacterial Surface Design of Titanium-Based Biomaterials for Enhanced Bacteria-Killing and Cell-Assisting Functions Against Periprosthetic Joint Infection.

    PubMed

    Wang, Jiaxing; Li, Jinhua; Qian, Shi; Guo, Geyong; Wang, Qiaojie; Tang, Jin; Shen, Hao; Liu, Xuanyong; Zhang, Xianlong; Chu, Paul K

    2016-05-04

    Periprosthetic joint infection (PJI) is one of the formidable and recalcitrant complications after orthopedic surgery, and inhibiting biofilm formation on the implant surface is considered crucial to prophylaxis of PJI. However, it has recently been demonstrated that free-floating biofilm-like aggregates in the local body fluid and bacterial colonization on the implant and peri-implant tissues can coexist and are involved in the pathogenesis of PJI. An effective surface with both contact-killing and release-killing antimicrobial capabilities can potentially abate these concerns and minimize PJI caused by adherent/planktonic bacteria. Herein, Ag nanoparticles (NPs) are embedded in titania (TiO2) nanotubes by anodic oxidation and plasma immersion ion implantation (PIII) to form a contact-killing surface. Vancomycin is then incorporated into the nanotubes by vacuum extraction and lyophilization to produce the release-killing effect. A novel clinical PJI model system involving both in vitro and in vivo use of methicillin-resistant Staphylococcus aureus (MRSA) ST239 is established to systematically evaluate the antibacterial properties of the hybrid surface against planktonic and sessile bacteria. The vancomycin-loaded and Ag-implanted TiO2 nanotubular surface exhibits excellent antimicrobial and antibiofilm effects against planktonic/adherent bacteria without appreciable silver ion release. The fibroblasts/bacteria cocultures reveal that the surface can help fibroblasts to combat bacteria. We first utilize the nanoarchitecture of implant surface as a bridge between the inorganic bactericide (Ag NPs) and organic antibacterial agent (vancomycin) to achieve total victory in the battle of PJI. The combination of contact-killing and release-killing together with cell-assisting function also provides a novel and effective strategy to mitigate bacterial infection and biofilm formation on biomaterials and has large potential in orthopedic applications.

  2. Covalent Immobilization of Enoxacin onto Titanium Implant Surfaces for Inhibiting Multiple Bacterial Species Infection and In Vivo Methicillin-Resistant Staphylococcus aureus Infection Prophylaxis

    PubMed Central

    Nie, Bin'en; Long, Teng; Ao, Haiyong; Zhou, Jianliang; Tang, Tingting

    2016-01-01

    ABSTRACT Infection is one of the most important causes of titanium implant failure in vivo. A developing prophylactic method involves the immobilization of antibiotics, especially vancomycin, onto the surface of the titanium implant. However, these methods have a limited effect in curbing multiple bacterial infections due to antibiotic specificity. In the current study, enoxacin was covalently bound to an amine-functionalized Ti surface by use of a polyethylene glycol (PEG) spacer, and the bactericidal effectiveness was investigated in vitro and in vivo. The titanium surface was amine functionalized with 3-aminopropyltriethoxysilane (APTES), through which PEG spacer molecules were covalently immobilized onto the titanium, and then the enoxacin was covalently bound to the PEG, which was confirmed by X-ray photoelectron spectrometry (XPS). A spread plate assay, confocal laser scanning microscopy (CLSM), and scanning electron microscopy (SEM) were used to characterize the antimicrobial activity. For the in vivo study, Ti implants were inoculated with methicillin-resistant Staphylococcus aureus (MRSA) and implanted into the femoral medullary cavity of rats. The degree of infection was assessed by radiography, micro-computed tomography, and determination of the counts of adherent bacteria 3 weeks after surgery. Our data demonstrate that the enoxacin-modified PEGylated Ti surface effectively prevented bacterial colonization without compromising cell viability, adhesion, or proliferation in vitro. Furthermore, it prevented MRSA infection of the Ti implants in vivo. Taken together, our results demonstrate that the use of enoxacin-modified Ti is a potential approach to the alleviation of infections of Ti implants by multiple bacterial species. PMID:27799220

  3. [LOCAL ANTIBIOTIC THERAPY OF OSTEOMYELITIS USING NONABSORBABLE IMPLANT (REVIEW)].

    PubMed

    Tuleubaev, B; Saginova, D; Abiyev, T; Davletbaev, M; Koshanova, A

    2016-06-01

    Despite the variety of treatments available, including surgical procedures and antimicrobial therapy, bone infections is still a medical problem, because they are difficult to treat. Optimal treatment should stabilize the bone, promote the biological recovery of bone defects and destroy bacterial infection. Systemic antibiotics are part of the standard therapy after surgical treatment of infected bone, but their effectiveness is limited due to malnutrition and low absorption at the site of infection. Moreover, long-term treatment and higher doses are associated with serious side effects. In contrast, the antibiotic impregnated bone cements or fillers can act as a local anti-infective drug delivery system, which not only fills the dead space after debridement, but also provide high concentrations of antibiotics in a potential site of infection, no increase levels of antibiotics in serum. The review analyzed the use of antibiotic-impregnated cement as local delivery of antibiotics systems. Gentamycin impregnated polymethylmethacrylate (PMMA) beads, for the topical treatment of orthopedic infections clinically used for over 30 years. Application of antibiotic delivery systems using cement in the infected region is common method of treatment that continues to improve. On the downside of PMMA is that the material does not biodegradable requires subsequent invasive procedures necessary to remove the implant.

  4. Scaling of titanium implants entrains inflammation-induced osteolysis

    PubMed Central

    Eger, Michal; Sterer, Nir; Liron, Tamar; Kohavi, David; Gabet, Yankel

    2017-01-01

    With millions of new dental and orthopedic implants inserted annually, periprosthetic osteolysis becomes a major concern. In dentistry, peri-implantitis management includes cleaning using ultrasonic scaling. We examined whether ultrasonic scaling releases titanium particles and induces inflammation and osteolysis. Titanium discs with machined, sandblasted/acid-etched and sandblasted surfaces were subjected to ultrasonic scaling and we physically and chemically characterized the released particles. These particles induced a severe inflammatory response in macrophages and stimulated osteoclastogenesis. The number of released particles and their chemical composition and nanotopography had a significant effect on the inflammatory response. Sandblasted surfaces released the highest number of particles with the greatest nanoroughness properties. Particles from sandblasted/acid-etched discs induced a milder inflammatory response than those from sandblasted discs but a stronger inflammatory response than those from machined discs. Titanium particles were then embedded in fibrin membranes placed on mouse calvariae for 5 weeks. Using micro-CT, we observed that particles from sandblasted discs induced more osteolysis than those from sandblasted/acid-etched discs. In summary, ultrasonic scaling of titanium implants releases particles in a surface type-dependent manner and may aggravate peri-implantitis. Future studies should assess whether surface roughening affects the extent of released wear particles and aseptic loosening of orthopedic implants. PMID:28059080

  5. Multisite Infection with Mycobacterium abscessus after Replacement of Breast Implants and Gluteal Lipofilling

    PubMed Central

    Rüegg, Eva; Cheretakis, Alexandre; Modarressi, Ali; Harbarth, Stephan; Pittet-Cuénod, Brigitte

    2015-01-01

    Introduction. Medical tourism for aesthetic surgery is popular. Nontuberculous mycobacteria (NTM) occasionally cause surgical-site infections. As NTM grow in biofilms, implantations of foreign bodies are at risk. Due to late manifestation, infections occur when patients are back home, where they must be managed properly. Case Report. A 39-year-old healthy female was referred for acute infection of the right gluteal area. Five months before, she had breast implants replacement, abdominal liposuction, and gluteal lipofilling in Mexico. Three months postoperatively, implants were removed for NTM-infection in Switzerland. Adequate antibiotic treatment was stopped after seven days for drug-related hepatitis. At entrance, gluteal puncture for bacterial analysis was performed. MRI showed large subcutaneous collection. Debridement under general anaesthesia was followed by open wound management. Total antibiotic treatment was 20 weeks. Methods. Bacterial analysis of periprosthetic and gluteal liquids included Gram-stain plus acid-fast stain, and aerobic, anaerobic and mycobacterial cultures.  Results. In periprosthetic fluid, Mycobacterium abscessus, Propionibacterium, and Staphylococcus epidermidis were identified. The same M. abscessus strain was found gluteally. The gluteal wound healed within six weeks. At ten months' follow-up, gluteal asymmetry persists for deep scarring. Conclusion. This case presents major complications of multisite aesthetic surgery. Surgical-site infections in context of medical tourism need appropriate bacteriological investigations, considering potential NTM-infections. PMID:25893122

  6. Medical Issues: Orthopedics

    MedlinePlus

    ... Cure SMA Store Volunteer Donate Learn About SMA Research Support & Care Get Involved Donate About Us News www.curesma.org > support & care > living with sma > medical issues > orthopedics Orthopedics In SMA, muscle weakness can cause several ...

  7. Effects of orthopedic implants with a polycaprolactone polymer coating containing bone morphogenetic protein-2 on osseointegration in bones of sheep.

    PubMed

    Niehaus, Andrew J; Anderson, David E; Samii, Valerie F; Weisbrode, Steven E; Johnson, Jed K; Noon, Mike S; Tomasko, David L; Lannutti, John J

    2009-11-01

    To determine elution characteristics of bone morphogenetic protein (BMP)-2 from a polycaprolactone coating applied to orthopedic implants and determine effects of this coating on osseointegration. 6 sheep. An in vitro study was conducted to determine BMP-2 elution from polycaprolactone-coated implants. An in vivo study was conducted to determine the effects on osseointegration when the polycaprolactone with BMP-2 coating was applied to bone screws. Osseointegration was assessed via radiography, measurement of peak removal torque and bone mineral density, and histomorphometric analysis. Physiologic response was assessed by measuring serum bone-specific alkaline phosphatase activity and uptake of bone markers. Mean +/- SD elution on day 1 of the in vitro study was 263 +/- 152 pg/d, which then maintained a plateau at 59.8 +/- 29.1 pg/d. Mean peak removal torque for screws coated with polycalprolactone and BMP-2 (0.91 +/- 0.65 dN x m) and screws coated with polycaprolactone alone (0.97 +/- 1.30 dN.m) did not differ significantly from that for the control screws (2.34 +/- 1.62 dN x m). Mean bone mineral densities were 0.535 +/- 0.060 g/cm(2), 0.596 +/- 0.093 g/cm(2), and 0.524 +/- 0.142 g/cm(2) for the polycaprolactone-BMP-2-coated, polycaprolactone-coated, and control screws, respectively, and did not differ significantly among groups. Histologically, bone was in closer apposition to the implant with the control screws than with either of the coated screws. BMP-2 within the polycaprolactone coating did not stimulate osteogenesis. The polycaprolactone coating appeared to cause a barrier effect that prevented formation of new bone. A longer period or use of another carrier polymer may result in increased osseointegration.

  8. Towards deployable meta-implants.

    PubMed

    Bobbert, F S L; Janbaz, S; Zadpoor, A A

    2018-06-07

    Meta-biomaterials exhibit unprecedented or rare combinations of properties not usually found in nature. Such unusual mechanical, mass transport, and biological properties could be used to develop novel categories of orthopedic implants with superior performance, otherwise known as meta-implants. Here, we use bi-stable elements working on the basis of snap-through instability to design deployable meta-implants. Deployable meta-implants are compact in their retracted state, allowing them to be brought to the surgical site with minimum invasiveness. Once in place, they are deployed to take their full-size load-bearing shape. We designed five types of meta-implants by arranging bi-stable elements in such a way to obtain a radially-deployable structure, three types of auxetic structures, and an axially-deployable structure. The intermediate stable conditions ( i.e. multi-stability features), deployment force, and stiffness of the meta-implants were found to be strongly dependent on the geometrical parameters of the bi-stable elements as well as on their arrangement.

  9. Biodegradable magnesium-based implants in bone studied by synchrotron radiation microtomography

    NASA Astrophysics Data System (ADS)

    Moosmann, Julian; Zeller-Plumhoff, Berit; Wieland, D. C. Florian; Galli, Silvia; Krüger, Diana; Dose, Thomas; Burmester, Hilmar; Wilde, Fabian; Bech, Martin; Peruzzi, Niccolò; Wiese, Björn; Hipp, Alexander; Beckmann, Felix; Hammel, Jörg; Willumeit-Römer, Regine

    2017-09-01

    Permanent implants made of titanium or its alloys are the gold standard in many orthopedic and traumatological applications due to their good biocompatibility and mechanical properties. However, a second surgical intervention is required for this kind of implants as they have to be removed in the case of children that are still growing or on patient's demand. Therefore, magnesium-based implants are considered for medical applications as they are degraded under physiological conditions. The major challenge is tailoring the degradation in a manner that is suitable for a biological environment and such that stabilization of the bone is provided for a controlled period. In order to understand failure mechanisms of magnesium-based implants in orthopedic applications and, further, to better understand the osseointegration, screw implants in bone are studied under mechanical load by means of a push-out device installed at the imaging beamline P05 of PETRA III at DESY. Conventional absorption contrast microtomography and phasecontrast techniques are applied in order to monitor the bone-to-implant interface under increasing load conditions. In this proof-of-concept study, first results from an in situ push-out experiment are presented.

  10. Osteomyelitis

    MedlinePlus

    ... bones vulnerable must be present. Recent injury or orthopedic surgery A severe bone fracture or a deep ... path for germs to enter a bone. Implanted orthopedic hardware is a risk factor for infection. Deep ...

  11. A novel phased-concept course for the delivery of anatomy and orthopedics training in medical education.

    PubMed

    Klima, Stefan; Hepp, Pierre; Löffler, Sabine; Cornwall, Jon; Hammer, Niels

    2017-07-01

    Integration of anatomy and clinical teaching is a theoretical ideal, yet there is a worldwide paucity of such amalgamation. These teaching models provide support for medical trainees, an important element in Germany where orthopedic intern numbers have declined and anecdotal evidence suggests disinterest in orthopedics. The aim of the study was to develop an integrated anatomy-surgical course for undergraduate medical training, assess the model developed, and explore how medical students perceive orthopedics as a career. The course was to deliver medical anatomy and clinical orthopedic training, focusing on interdisciplinary teaching and learning, vertical integration of clinical knowledge and skills, and professional interaction. Survey evaluation of the course and students' perceptions of orthopedic careers was performed, including Likert-type responses rating variables of interest. A phased-concept program of five courses, each optional and under one-week in duration, was developed parallel to the undergraduate medical program. Delivered by anatomists and surgeons, courses included biomechanics, advanced dissection, surgical approaches, casts and implants, and sports medicine. Course data indicate positive support for course format, stimulation of interest, and high clinical relevance. Students are generally interested in surgery, and identify hierarchy, lawsuits, bureaucracy and physical stress as barriers to orthopedic careers. This novel phased-concept successfully delivers combined anatomy and surgery training in a vertically-integrated format while addressing students' clinical and professional skills. The format facilitates an appreciation of potential career options in orthopedics, while fostering professional skills during medical training. Barriers to careers in orthopedics can now be addressed in future courses. Anat Sci Educ 10: 372-382. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  12. Complications and risk factors of infection in pediatric hemato-oncology patients with totally implantable access ports (TIAPs).

    PubMed

    Nam, So-Hyun; Kim, Dae-Yeon; Kim, Seong-Chul; Kim, In-Koo

    2010-04-01

    Totally implantable access ports (TIAPs) are widely used in pediatric hematology-oncology patients. We investigated the incidence of complications, causes of TIAP removal, and risk factors for infection. We retrospectively analyzed the clinical, demographic, and surgical characteristics in 225 pediatric hematology-oncology patients implanted with 238 TIAPs between January 2004 and December 2005. Except for 20 patients lost to follow-up, the mean maintenance period was 724.8 +/- 500.6 days (range: 17-2,124). Mechanical complications occurred in seven patients (2.9%). The causes of TIAP removal were termination of use in 130 patients (59.6%), death from primary disease with TIAP in situ in 35 (14.7%), infection in 35 (14.7%), and obstruction in 4 (1.8%). Early infections occurred in nine patients at mean 37.77 +/- 16.44 days (range: 17-56). Late infections occurred in 26 patients at mean 334.5 +/- 257.82 days (range: 68-997). Univariate analysis showed that the risk factors of early infection were re-implantation (P = 0.022) and long operation time (P = 0.045). The risk factors of late infection were ANC <500/mm(3) (P = 0.011) and platelet count <50,000/mm(3) (P < 0.001). In multivariate analysis, re-implantation was a significant risk factor of early infection (P = 0.033, OR 4.528) and low platelet count (<50,000/mm(3)) was the independent risk factor for late infection (P = 0.005, OR 4.24). Correct procedure and careful use decreases the incidence of early infection and leads to the prevention of re-implantation. Initial thrombocytopenia was attributable to bone marrow suppression caused by hematologic malignancies or severe infection. Thus, this condition is of value in predicting late infection.

  13. Biofilms in periprosthetic orthopedic infections

    PubMed Central

    McConoughey, Stephen J; Howlin, Rob; Granger, Jeff F; Manring, Maurice M; Calhoun, Jason H; Shirtlif, Mark; Kathju, Sandeep; Stoodley, Paul

    2015-01-01

    As the number of total joint arthroplasty and internal fixation procedures continues to rise, the threat of infection following surgery has significant clinical implications. These infections may have highly morbid consequences to patients, who often endure additional surgeries and lengthy exposures to systemic antibiotics, neither of which are guaranteed to resolve the infection. Of particular concern is the threat of bacterial biofilm development, since biofilm-mediated infections are difficult to diagnose and effective treatments are lacking. Developing therapeutic strategies have targeted mechanisms of biofilm formation and the means by which these bacteria communicate with each other to take on specialized roles such as persister cells within the biofilm. In addition, prevention of infection through novel coatings for prostheses and the local delivery of high concentrations of antibiotics by absorbable carriers has shown promise in laboratory and animal studies. Biofilm development, especially in an arthoplasty environment, and future diagnostic and treatment options are discussed. PMID:25302955

  14. Effectiveness of Antimicrobial Peptide Immobilization for Preventing Perioperative Cornea Implant-Associated Bacterial Infection

    PubMed Central

    Tan, Xiao Wei; Goh, Tze Wei; Saraswathi, P.; Nyein, Chan Lwin; Setiawan, Melina; Riau, Andri; Lakshminarayanan, R.; Liu, Shouping; Tan, Donald; Beuerman, Roger W.

    2014-01-01

    Titanium (Ti) is a promising candidate biomaterial for an artificial corneal skirt. Antimicrobial peptide (AMP) immobilization may improve the bactericidal effect of the Ti substrate. In this study, we tested the bactericidal efficacy of a functionalized Ti surface in a rabbit keratitis model. A corneal stromal pocket was created by a femtosecond laser. The Ti films were then inserted into the pocket, and Staphylococcus aureus or Pseudomonas aeruginosa was inoculated into the pocket above the implant films. The corneas with Ti-AMP implants were compared with the corneas implanted with unprotected Ti by slit lamp observation and anterior segment optical coherence tomography (AS-OCT). Inflammatory responses were evaluated by bacterium counting, hematoxylin-eosin staining, and immunostaining. There was a lower incidence and a lesser extent of infection on rabbit corneas with Ti-AMP implants than on those with unprotected Ti implants. The bactericidal effect of AMP against S. aureus was comparable to that of postoperative prophylactic antibiotic treatment; hence, SESB2V AMP bound to the Ti implant provided functional activity in vivo, but its efficacy was greater against S. aureus than against P. aeruginosa. This work suggests that SESB2V AMP can be successfully functionalized in a rabbit keratitis model to prevent perioperative corneal infection. PMID:24957820

  15. Early osteoblast responses to orthopedic implants: Synergy of surface roughness and chemistry of bioactive ceramic coating.

    PubMed

    Aniket; Reid, Robert; Hall, Benika; Marriott, Ian; El-Ghannam, Ahmed

    2015-06-01

    Pro-osteogenic stimulation of bone cells by bioactive ceramic-coated orthopedic implants is influenced by both surface roughness and material chemistry; however, their concomitant impact on osteoblast behavior is not well understood. The aim of this study is to investigate the effects of nano-scale roughness and chemistry of bioactive silica-calcium phosphate nanocomposite (SCPC50) coated Ti-6Al-4V on modulating early bone cell responses. Cell attachment was higher on SCPC50-coated substrates compared to the uncoated controls; however, cells on the uncoated substrate exhibited greater spreading and superior quality of F-actin filaments than cells on the SCPC50-coated substrates. The poor F-actin filament organization on SCPC50-coated substrates is thought to be due to the enhanced calcium uptake by the ceramic surface. Dissolution analyses showed that an increase in surface roughness was accompanied by increased calcium uptake, and increased phosphorous and silicon release, all of which appear to interfere with F-actin assembly and osteoblast morphology. Moreover, cell attachment onto the SCPC50-coated substrates correlated with the known adsorption of fibronectin, and was independent of surface roughness. High-throughput genome sequencing showed enhanced expression of extracellular matrix and cell differentiation related genes. These results demonstrate a synergistic relationship between bioactive ceramic coating roughness and material chemistry resulting in a phenotype that leads to early osteoblast differentiation. © 2014 Wiley Periodicals, Inc.

  16. A Resorbable Antibiotic-Eluting Polymer Composite Bone Void Filler for Perioperative Infection Prevention in a Rabbit Radial Defect Model

    PubMed Central

    Brooks, Benjamin D.; Sinclair, Kristofer D.; Grainger, David W.; Brooks, Amanda E.

    2015-01-01

    Nearly 1.3 million total joint replacement procedures are performed in the United States annually, with numbers projected to rise exponentially in the coming decades. Although finite infection rates for these procedures remain consistently low, device-related infections represent a significant cause of implant failure, requiring secondary or revision procedures. Revision procedures manifest several-fold higher infection recurrence rates. Importantly, many revision surgeries, infected or not, require bone void fillers to support the host bone and provide a sufficient tissue bed for new hardware placement. Antibiotic-eluting bone void fillers (ABVF), providing both osteoconductive and antimicrobial properties, represent one approach for reducing rates of orthopedic device-related infections. Using a solvent-free, molten-cast process, a polymer-controlled antibiotic-eluting calcium carbonate hydroxyapatite (HAP) ceramic composite BVF (ABVF) was fabricated, characterized, and evaluated in vivo using a bacterial challenge in a rabbit radial defect window model. ABVF loaded with tobramycin eliminated the infectious burden in rabbits challenged with a clinically relevant strain of Staphylococcus aureus (inoculum as high as 107 CFU). Histological, microbiological, and radiographic methods were used to detail the effects of ABVF on microbial challenge to host bone after 8 weeks in vivo. In contrast to the HAP/BVF controls, which provided no antibiotic protection and required euthanasia 3 weeks post-operatively, tobramycin-releasing ABVF animals showed no signs of infection (clinical, microbiological, or radiographic) when euthanized at the 8-week study endpoint. ABVF sites did exhibit fibrous encapsulation around the implant at 8 weeks. Local antibiotic release from ABVF to orthopedic sites requiring bone void fillers eliminated the periprosthetic bacterial challenge in this 8-week in vivo study, confirming previous in vitro results. PMID:25815727

  17. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    PubMed

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  18. Improved osseointegration properties of hierarchical microtopographic/nanotopographic coatings fabricated on titanium implants.

    PubMed

    Zemtsova, Elena G; Yudintceva, Natalia M; Morozov, Pavel E; Valiev, Ruslan Z; Smirnov, Vladimir M; Shevtsov, Maxim A

    2018-01-01

    Titanium (Ti) implants are extensively used in reconstructive surgery and orthopedics. However, the intrinsic inertness of untreated Ti implants usually results in insufficient osseointegration. In order to improve the osteoconductivity properties of the implants, they are coated with hierarchical microtopographic/nanotopographic coatings employing the method of molecular layering of atomic layer deposition (ML-ALD). The analysis of the fabricated nanostructured relief employing scanning electron microscopy, atomic force microscopy, and electron spectroscopy for chemical analysis clearly demonstrated the formation of the nanotopographic (<100 nm) and microtopographic (0.1-0.5 μm) titano-organic structures on the surface of the nanograined Ti implants. Subsequent coincubation of the MC3T3-E1 mouse osteoblasts on the microtopographic/nanotopographic surface of the implants resulted in enhanced osteogenic cell differentiation (the production of alkaline phosphatase, osteopontin, and osteocalcin). In vivo assessment of the osseointegrative properties of the microtopographically/nanotopographically coated implants in a model of below-knee amputation in New Zealand rabbits demonstrated enhanced new bone formation in the zone of the bone-implant contact (as measured by X-ray study) and increased osseointegration strength (removal torque measurements). The fabrication of the hierarchical microtopographic/nanotopographic coatings on the nanograined Ti implants significantly improves the osseointegrative properties of the intraosseous Ti implants. This effect could be employed in both translational and clinical studies in orthopedic and reconstructive surgery.

  19. The prospect of carbon fiber implants in radiotherapy

    PubMed Central

    Xiao‐bin, Tang; Chang‐ran, Geng; Da, Chen

    2012-01-01

    Because of their superior characteristics, carbonaceous materials, which are still at their early stage of development, have garnered significant interest. Because of their low atomic number, carbonaceous orthopedic implants possess radiation properties similar to biological tissues and, therefore, they are more suitable to patients in need of radiotherapy. The effects of stainless steel, titanium, and carbon plates on radiation dose distributions were investigated in this work using Monte Carlo simulations and TLD measurements for 6 MV photon beams. It is found that carbon plates will neither increase the incident surface dose, nor lead to the decrease of exit surface dose (the effect of a second build‐up). Carbon fiber orthopedic implants have a good prospect for radiotherapy patients because they have minimal perturbation effects on the radiotherapy dose distribution. PACS number: 87.55.K‐,87.55.Gh, 87.55.ne PMID:22766953

  20. Impact of a surgical site infection (SSI) surveillance program in orthopedics and traumatology.

    PubMed

    Mabit, C; Marcheix, P S; Mounier, M; Dijoux, P; Pestourie, N; Bonnevialle, P; Bonnomet, F

    2012-10-01

    Surveillance of surgical site infections (SSI) is a priority. One of the fundamental principles for the surveillance of SSI is based on receiving effective field feedback (retro-information). The aim of this study was to report the results of a program of SSI surveillance and validate the hypothesis that there is a correlation between creating a SSI surveillance program and a reduction in SSI. The protocol was based on the weekly collection of surveillance data obtained directly from the different information systems in different departments. A delay of 3 months was established before extraction and analysis of data and information from the surgical teams. The NNIS index (National Nosocomial Infections Surveillance System) developed by the American surveillance system and the reduction of length of hospital stay index Journées d'hospitalisation évitées (JHE). Since the end of 2009, 7156 surgical procedures were evaluated (rate of inclusion 97.3%), and 84 SSI were registered with a significant decrease over time from 1.86% to 0.66%. A total of 418 days of hospitalization have been saved since the beginning of the surveillance system. Our surveillance system has three strong points: follow-up is continuous, specifically adapted to orthopedic traumatology and nearly exhaustive. The extraction of data directly from hospital information systems effectively improves the collection of data on surgical procedures. The implementation of a SSI surveillance protocol reduces SSI. Level III. Prospective study. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  1. Retrospective comparative analysis of cardiovascular implantable electronic device infections with and without the use of antibacterial envelopes.

    PubMed

    Hassoun, A; Thottacherry, E D; Raja, M; Scully, M; Azarbal, A

    2017-03-01

    Cardiovascular implantable electronic device (CIED) infections are associated with morbidity and mortality. Peri-operative systemic intravenous antibiotic prophylaxis reduces the rate of CIED infections. AIGIS Rx , a polymer envelope implanted with the CIED, releases minocycline and rifampin, and has been introduced to reduce infections. Retrospective review of 184 patients who underwent CIED implantation was conducted. Ninety-two patients were implanted with an AIGIS Rx envelope (AIGIS Rx group) and 92 patients were not implanted with an AIGIS Rx envelope (control group). Data were collected on demographics and risk factors for CIED infections (i.e. congestive heart failure, renal insufficiency, chronic kidney disease, oral anticoagulant use, chronic steroid use, need for lead replacement or revision, temporary pacing, early re-intervention, and having more than two leads in place). Rates of implantation success, major infections and mortality were compared between the AIGIS Rx group and the control group. The AIGIS Rx group had longer hospitalizations (6.8±10.7 days vs 3.1±5.2 days; P=0.001), higher chronic corticosteroid use, higher rates of replacement or revision (51.1% vs 8.7%; P=0.001), and a greater proportion of devices with more than two intracardiac leads (42.4% vs 29.3%; P=0.03) than the control group. Successful implantation occurred in 97% of patients in both groups. Major infection was seen in 5.4% of cases in the AIGIS Rx group and 1.1% of cases in the control group (P=0.048). Device removal was conducted in 3.3% of cases in the AIGIS Rx group compared with 1.1% of cases in the control group (P=0.16). There were two deaths in the AIGIS Rx group. Organisms cultured were meticillin-resistant Staphylococcus aureus, meticillin-susceptible S. aureus and Enterococcus faecalis. The AIGIS Rx group had higher rates of major infection but also higher risk factors compared with the control group. The rate of device extraction and CIED-related mortality was

  2. The Effectiveness of the Controlled Release of Gentamicin from Polyelectrolyte Multilayers in the Treatment of Staphylococcus aureus Infection in a Rabbit Bone Model

    PubMed Central

    Moskowitz, Joshua; Blaisse, Michael; Samuel, Raymond; Hsu, Hu-Ping; Harris, Mitchel; Martin, Scott; Lee, Jean; Spector, Myron; Hammond, Paula

    2010-01-01

    While the infection rate of orthopedic implants is low, the required treatment, which can involve six weeks of antibiotic therapy and two additional surgical operations, is life threatening and expensive, and thus motivates the development of a one-stage re-implantation procedure. Polyelectrolyte multilayers incorporating gentamicin were fabricated using the layer-by-layer deposition process for use as a device coating to deal with an existing bone infection in a direct implant exchange operation. The films eluted about 70% of their payload in vitro during the first three days and subsequently continued to release drug for more than four additional weeks, reaching a total average release of over 550 μg/cm2. The coatings were demonstrated to be bactericidal against Staphylococcus aureus, and degradation products were generally nontoxic towards MC3T3-E1 murine preosteoblasts. Film-coated titanium implants were compared to uncoated implants in an in vivo S. aureus bone infection model. After a direct exchange procedure, the antimicrobial-coated devices yielded bone homogenates with a significantly lower degree of infection than uncoated devices at both day four (p < 0.004) and day seven (p < 0.03). This study has demonstrated that a self-assembled ultrathin film coating is capable of effectively treating an experimental bone infection in vivo and lays the foundation for development of a multi-therapeutic film for optimized, synergistic treatment of pain, infection, and osteomyelitis. PMID:20488534

  3. Kaiser Permanente implant registries benefit patient safety, quality improvement, cost-effectiveness.

    PubMed

    Paxton, Elizabeth W; Kiley, Mary-Lou; Love, Rebecca; Barber, Thomas C; Funahashi, Tadashi T; Inacio, Maria C S

    2013-06-01

    In response to the increased volume, risk, and cost of medical devices, in 2001 Kaiser Permanente (KP) developed implant registries to enhance patient safety and quality, and to evaluate cost-effectiveness. Using an integrated electronic health record system, administrative databases, and other institutional databases, orthopedic, cardiology, and vascular implant registries were developed in 2001, 2006, and 2011, respectively. These registries monitor patients, implants, clinical practices, and surgical outcomes for KP's 9 million members. Critical to registry success is surgeon leadership and engagement; each geographical region has a surgeon champion who provides feedback on registry initiatives and disseminates registry findings. The registries enhance patient safety by providing a variety of clinical decision tools such as risk calculators, quality reports, risk-adjusted medical center reports, summaries of surgeon data, and infection control reports to registry stakeholders. The registries are used to immediately identify patients with recalled devices, evaluate new and established device technology, and identify outlier implants. The registries contribute to cost-effectiveness initiatives through collaboration with sourcing and contracting groups and confirming adherence to device formulary guidelines. Research studies based on registry data have directly influenced clinical best practices. Registries are important tools to evaluate longitudinal device performance and safety, study the clinical indications for and outcomes of device implantation, respond promptly to recalls and advisories, and contribute to the overall high quality of care of our patients.

  4. Evaluation of the Etiologies of Implant Fracture in Patients With Fractures of the Implants of Lower Limbs’ Long Bones

    PubMed Central

    Yeganeh, Ali; Otoukesh, Babak; Kaghazian, Peyman; Yeganeh, Nima; Boddohi, Bahram; Moghtadaei, Mehdi

    2015-01-01

    Background: Orthopedics implants are important tools for treatment of bone fractures. Despite available recommendations for designing and making the implants, there are multiple cases of fracture of these implants in the body. Hence, in this study the frequency of failure of implants in long bones of lower extremities was evaluated. Methods and Materials: In this cross-sectional study, two types of fractured implants in the body were analyzed and underwent metalogical, mechanical, and modeling and stress-bending analysis. Results: The results revealed that the main cause of fractures was decreased mechanical resistance due to inappropriate chemical composition (especially decreased percentages of Nickel and Molybdenum). Conclusions: It may be concluded that following the standard chemical composition and use of optimal making method are the most important works for prevention of failure of implants. PMID:26843735

  5. Bacterial biofilms on implanted suture material are a cause of surgical site infection.

    PubMed

    Kathju, Sandeep; Nistico, Laura; Tower, Irene; Lasko, Leslie-Ann; Stoodley, Paul

    2014-10-01

    Surgical site infection (SSI) has been estimated to occur in up to 5% of all procedures, accounting for up to 0.5% of all hospital costs. Bacterial biofilms residing on implanted foreign bodies have been implicated as contributing or causative factors in a wide variety of infectious scenarios, but little consideration has been given to the potential for implanted, submerged suture material to act as a host for biofilm and thus serve as a nidus of infection. We report a series of 15 patients who underwent open Roux-en-Y gastric bypass (with musculofascial closure with permanent, multifilament sutures) who developed longstanding and refractory SSIs in the abdominal wall. Explanted suture material at subsequent exploration was examined for biofilm with confocal laser-scanning microscopy (CLSM) and fluorescence in situ hybridization (FISH). All 15 patients at re-exploration were found to have gross evidence of a "slimy" matrix or dense reactive granulation tissue localized to the implanted sutures. Confocal laser-scanning microscopy revealed abundant biofilm present on all sutures examined; FISH was able to identify the presence of specific pathogens in the biofilm. Complete removal of the foreign bodies (and attendant biofilms) resulted in all cases in cure of the SSI. Bacterial biofilms on implanted suture material can manifest as persistent surgical site infections that require complete removal of the underlying foreign body substrata for resolution.

  6. Multi-Disciplinary Antimicrobial Strategies for Improving Orthopaedic Implants to Prevent Prosthetic Joint Infections in Hip and Knee

    PubMed Central

    Getzlaf, Matthew A.; Lewallen, Eric A.; Kremers, Hilal M.; Jones, Dakota L.; Bonin, Carolina A.; Dudakovic, Amel; Thaler, Roman; Cohen, Robert C.; Lewallen, David G.; van Wijnen, Andre J.

    2016-01-01

    Like any foreign object, orthopaedic implants are susceptible to infection when introduced into the human body. Without additional preventative measures, the absolute number of annual prosthetic joint infections will continue to rise, and may exceed the capacity of health care systems in the near future. Bacteria are difficult to eradicate from synovial joints due to their exceptionally diverse taxonomy, complex mechanistic attachment capabilities, and tendency to evolve antibiotic resistance. When a primary orthopaedic implant fails from prosthetic joint infection, surgeons are generally challenged by limited options for intervention. In this review, we highlight the etiology and taxonomic groupings of bacteria known to cause prosthetic joint infections, and examine their key mechanisms of attachment. We propose that antimicrobial strategies should focus on the most harmful bacteria taxa within the context of occurrence, taxonomic diversity, adhesion mechanisms, and implant design. Patient-specific identification of organisms that cause prosthetic joint infections will permit assessment of their biological vulnerabilities. The latter can be targeted using a range of antimicrobial techniques that exploit different colonization mechanisms including implant surface attachment, biofilm formation, and/or hematogenous recruitment. We anticipate that customized strategies for each patient, joint, and prosthetic component will be most effective at reducing prosthetic joint infections, including those caused by antibiotic-resistant and polymicrobial bacteria. PMID:26449208

  7. Molecular Diagnosis of Orthopedic-Device-Related Infection Directly from Sonication Fluid by Metagenomic Sequencing

    PubMed Central

    Sanderson, Nicholas D.; Atkins, Bridget L.; Brent, Andrew J.; Cole, Kevin; Foster, Dona; McNally, Martin A.; Oakley, Sarah; Peto, Leon; Taylor, Adrian; Peto, Tim E. A.; Crook, Derrick W.; Eyre, David W.

    2017-01-01

    ABSTRACT Culture of multiple periprosthetic tissue samples is the current gold standard for microbiological diagnosis of prosthetic joint infections (PJI). Additional diagnostic information may be obtained through culture of sonication fluid from explants. However, current techniques can have relatively low sensitivity, with prior antimicrobial therapy and infection by fastidious organisms influencing results. We assessed if metagenomic sequencing of total DNA extracts obtained direct from sonication fluid can provide an alternative rapid and sensitive tool for diagnosis of PJI. We compared metagenomic sequencing with standard aerobic and anaerobic culture in 97 sonication fluid samples from prosthetic joint and other orthopedic device infections. Reads from Illumina MiSeq sequencing were taxonomically classified using Kraken. Using 50 derivation samples, we determined optimal thresholds for the number and proportion of bacterial reads required to identify an infection and confirmed our findings in 47 independent validation samples. Compared to results from sonication fluid culture, the species-level sensitivity of metagenomic sequencing was 61/69 (88%; 95% confidence interval [CI], 77 to 94%; for derivation samples 35/38 [92%; 95% CI, 79 to 98%]; for validation samples, 26/31 [84%; 95% CI, 66 to 95%]), and genus-level sensitivity was 64/69 (93%; 95% CI, 84 to 98%). Species-level specificity, adjusting for plausible fastidious causes of infection, species found in concurrently obtained tissue samples, and prior antibiotics, was 85/97 (88%; 95% CI, 79 to 93%; for derivation samples, 43/50 [86%; 95% CI, 73 to 94%]; for validation samples, 42/47 [89%; 95% CI, 77 to 96%]). High levels of human DNA contamination were seen despite the use of laboratory methods to remove it. Rigorous laboratory good practice was required to minimize bacterial DNA contamination. We demonstrate that metagenomic sequencing can provide accurate diagnostic information in PJI. Our findings

  8. Preoperative Planning of Orthopedic Procedures using Digitalized Software Systems.

    PubMed

    Steinberg, Ely L; Segev, Eitan; Drexler, Michael; Ben-Tov, Tomer; Nimrod, Snir

    2016-06-01

    The progression from standard celluloid films to digitalized technology led to the development of new software programs to fulfill the needs of preoperative planning. We describe here preoperative digitalized programs and the variety of conditions for which those programs can be used to facilitate preparation for surgery. A PubMed search using the keywords "digitalized software programs," "preoperative planning" and "total joint arthroplasty" was performed for all studies regarding preoperative planning of orthopedic procedures that were published from 1989 to 2014 in English. Digitalized software programs are enabled to import and export all picture archiving communication system (PACS) files (i.e., X-rays, computerized tomograms, magnetic resonance images) from either the local working station or from any remote PACS. Two-dimension (2D) and 3D CT scans were found to be reliable tools with a high preoperative predicting accuracy for implants. The short learning curve, user-friendly features, accurate prediction of implant size, decreased implant stocks and low-cost maintenance makes digitalized software programs an attractive tool in preoperative planning of total joint replacement, fracture fixation, limb deformity repair and pediatric skeletal disorders.

  9. Hydroxyapatite ocular implant and non-integrated implants in eviscerated patients

    PubMed Central

    Gradinaru, S; Popescu, V; Leasu, C; Pricopie, S; Yasin, S; Ciuluvica, R; Ungureanu, E

    2015-01-01

    Introduction: This study compares the outcomes and complications of hydroxyapatite ocular implant and non-integrated ocular implants following evisceration. Materials and Methods: This is a retrospective study of 90 patients who underwent evisceration for different ocular affections, in the Ophthalmology Department of the University Emergency Hospital Bucharest, between January 2009 and December 2013. The outcomes measured were conjunctival dehiscence, socket infection, implant exposure and extrusion rate. Results: Forty-three patients had the hydroxyapatite implant (coralline–Integrated Ocular Implants, USA or synthetic–FCI, France) and forty-seven received non-integrated ocular implants (24 acrylic and 23 silicone). Five cases of socket infection, thirteen cases of extrusion and two cases of conjunctival dehiscence were encountered. Conclusions: There was a higher rate of conjunctival dehiscence with hydroxyapatite ocular implant, but implant extrusion and socket infection were found in non-integrated ocular implants. PMID:25914747

  10. Influence of orthopedic reinforced gloves versus double standard gloves on contamination events during small animal orthopedic surgery.

    PubMed

    Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie

    2017-10-01

    To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P < .001) with each additional minute of surgery. Orthopedic reinforced gloves and double standard gloving were equally effective at preventing contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.

  11. Orthopedic workforce planning in Germany – an analysis of orthopedic accessibility

    PubMed Central

    Müller, Peter; Maier, Werner; Groneberg, David A.

    2017-01-01

    In Germany, orthopedic workforce planning relies on population-to-provider-ratios represented by the ‘official degree of care provision’. However, with geographic information systems (GIS), more sophisticated measurements are available. By utilizing GIS-based technologies we analyzed the current state of demand and supply of the orthopedic workforce in Germany (orthopedic accessibility) with the integrated Floating Catchment Area method. The analysis of n = 153,352,220 distances revealed significant geographical variations on national scale: 5,617,595 people (6.9% of total population) lived in an area with significant low orthopedic accessibility (average z-score = -4.0), whereas 31,748,161 people (39.0% of total population) lived in an area with significant high orthopedic accessibility (average z-score = 8.0). Accessibility was positively correlated with the degree of urbanization (r = 0.49; p<0.001) and the official degree of care provision (r = 0.33; p<0.001) and negatively correlated with regional social deprivation (r = -0.47; p<0.001). Despite advantages of simpler measures regarding implementation and acceptance in health policy, more sophisticated measures of accessibility have the potential to reduce costs as well as improve health care. With this study, significant geographical variations were revealed that show the need to reduce oversupply in less deprived urban areas in order to enable adequate care in more deprived rural areas. PMID:28178335

  12. [The beginnings of orthopedic surgery in Israel].

    PubMed

    Tauber, Chanan

    2013-08-01

    In early mandatory Israel, orthopedics was mainly conservative, The first modern orthopedic surgeon was Ernst Spira from Czechoslovakia who established an orthopedic service at the Beilinson Hospital in Petah Tikva and left in 1948 to establish the Orthopedic Department and the Rehabilitation Center in Tel Hashomer, which treated the War of Independence casualties including amputees and victims of spinal cord injuries. A second orthopedic department was opened in Tel Hashomer by Shmuel Weissman who left in 1961 to open the Orthopedic Department at the Ichilov hospital in Tel Aviv. Shmuel Weissman became the first Chairman of Orthopedic Surgery at the Tel Aviv University medical school. In 1955, Myer Makin opened a modern orthopedic department in the Hadassah Hospital in Jerusalem and the Alyn Hospital for crippled children. In 1951, Assaf Harofeh Hospital opened the Department of Orthopedic Surgery headed by Anatol Axer who specialized in the treatment and rehabilitation of polio patients. The majority of the second generation of orthopedic department directors was trained by these four surgeons. Major developments in the 1960s and 1970s were the introduction of the AO system revolutionizing fracture treatment from conservative to operative treatment, the advent of total hip and knee replacements, Harrington instrumentation in spinal surgery and arthroscopy were major advances in orthopedic patient care brought to Israel by the aforementioned second generation of orthopedic surgeons. Hand surgery became an independent subspecialty of orthopedics and was lead by the internationally renowned hand surgeon, Isidore Kessler.

  13. Sol-Gel Derived Hydroxyapatite Coating on Mg-3Zn Alloy for Orthopedic Application

    NASA Astrophysics Data System (ADS)

    Singh, Sanjay; Manoj Kumar, R.; Kuntal, Kishor Kumar; Gupta, Pallavi; Das, Snehashish; Jayaganthan, R.; Roy, Partha; Lahiri, Debrupa

    2015-04-01

    In recent years, magnesium and its alloys have gained a lot of interest as orthopedic implant constituents because their biodegradability and mechanical properties are closer to that of human bone. However, one major concern with Mg in orthopedics is its high corrosion rate that results in the reduction of mechanical integrity before healing the bone tissue. The current study evaluates the sol-gel-derived hydroxyapatite (HA) coating on a selected Mg alloy (Mg-3Zn) for decreasing the corrosion rate and increasing the bioactivity of the Mg surface. The mechanical integrity of the coating is established as a function of the surface roughness of the substrate and the sintering temperature of the coating. Coating on a substrate roughness of 15-20 nm and sintering at 400°C shows the mechanical properties in similar range of bone, thus making it suitable to avoid the stress-shielding effect. The hydroxyapatite coating on the Mg alloy surface also increases corrosion resistance very significantly by 40 times. Bone cells are also found proliferating better in the HA-coated surface. All these benefits together establish the candidature of sol-gel HA-coated Mg-3Zn alloy in orthopedic application.

  14. Spinal Stabilization Using Orthopedic Extremity Instrumentation Sets During Operation Enduring Freedom-Afghanistan.

    PubMed

    Ravindra, Vijay M; Wallace, Scott A; Vaidya, Rahul; Fox, W Christopher; Klugh, Arnett R; Puskas, David; Park, Min S

    2016-02-01

    The Role III, Multinational Medical Unit at Kandahar Air Field, Afghanistan, was established to provide combat casualty care in theater for International Security Assistance Forces, Afghanistan National Security Forces, and local nationals during Operation Enduring Freedom-Afghanistan. The authors describe their experience of treating unstable lumbar spine fractures with orthopedic extremity instrumentation sets from January 2007 to January 2008 and November 2010 to May 2011. During the study periods, 15 patients comprising Afghanistan National Security Forces and local nationals presented to the medical facility for treatment of unstable lumbar spine fractures. The patients underwent surgery for either anterior corpectomy and instrumented fusion (n = 5) or posterior instrumented fusion (n = 10). Because of periodic scarcity of spinal instrumentation sets, orthopedic extremity instrumentation sets were used (Synthes Large Fragment LCP Instrument and Implant Set) for spinal stabilization. Immediate postoperative standing and sitting plain radiographs demonstrated no evidence of fracture progression or immediate hardware failure. One patient was seen in follow-up at 4 weeks and demonstrated construct stability on follow-up radiographs. In the combat environment with sparse resources, unstable spine fractures may potentially be treated using instrumentation not specifically designed for spinal implantation. This is an off-label use, and the authors do not recommend the use of these techniques as standard treatment in most medical environments. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Multiscale design and multiobjective optimization of orthopedic hip implants with functionally graded cellular material.

    PubMed

    Arabnejad Khanoki, Sajad; Pasini, Damiano

    2012-03-01

    Revision surgeries of total hip arthroplasty are often caused by a deficient structural compatibility of the implant. Two main culprits, among others, are bone-implant interface instability and bone resorption. To address these issues, in this paper we propose a novel type of implant, which, in contrast to current hip replacement implants made of either a fully solid or a foam material, consists of a lattice microstructure with nonhomogeneous distribution of material properties. A methodology based on multiscale mechanics and design optimization is introduced to synthesize a graded cellular implant that can minimize concurrently bone resorption and implant interface failure. The procedure is applied to the design of a 2D left implanted femur with optimized gradients of relative density. To assess the manufacturability of the graded cellular microstructure, a proof-of-concept is fabricated by using rapid prototyping. The results from the analysis are used to compare the optimized cellular implant with a fully dense titanium implant and a homogeneous foam implant with a relative density of 50%. The bone resorption and the maximum value of interface stress of the cellular implant are found to be over 70% and 50% less than the titanium implant while being 53% and 65% less than the foam implant.

  16. Biofilm formation on titanium implants counteracted by grafting gallium and silver ions.

    PubMed

    Cochis, Andrea; Azzimonti, Barbara; Della Valle, Cinzia; Chiesa, Roberto; Arciola, Carla Renata; Rimondini, Lia

    2015-03-01

    Biofilm-associated infections remain the leading cause of implant failure. Thanks to its established biocompatibility and biomechanical properties, titanium has become one of the most widely used materials for bone implants. Engineered surface modifications of titanium able to thwart biofilm formation while endowing a safe anchorage to eukaryotic cells are being progressively developed. Here surfaces of disks of commercial grade 2 titanium for bone implant were grafted with gallium and silver ions by anodic spark deposition. Scanning electron microscopy of the surface morphology and energy dispersive X-ray spectroscopy were used for characterization. Gallium-grafted titanium was evaluated in comparison with silver-grafted titanium for both in vivo and in vitro antibiofilm properties and for in vitro compatibility with human primary gingival fibroblasts. Surface-modified materials showed: (i) homogeneous porous morphology, with pores of micrometric size; (ii) absence of cytotoxic effects; (iii) ability to support in vitro the adhesion and spreading of gingival fibroblasts; and (iv) antibiofilm properties. Although both silver and gallium exhibited in vitro strong antibacterial properties, in vivo gallium was significantly more effective than silver in reducing number and viability of biofilm bacteria colonies. Gallium-based treatments represent promising titanium antibiofilm coatings to develop new bone implantable devices for oral, maxillofacial, and orthopedic applications. © 2014 Wiley Periodicals, Inc.

  17. Allergic contact dermatitis caused by titanium screws and dental implants.

    PubMed

    Hosoki, Maki; Nishigawa, Keisuke; Miyamoto, Youji; Ohe, Go; Matsuka, Yoshizo

    2016-07-01

    Titanium has been considered to be a non-allergenic material. However, several studies have reported cases of metal allergy caused by titanium-containing materials. We describe a 69-year-old male for whom significant pathologic findings around dental implants had never been observed. He exhibited allergic symptoms (eczema) after orthopedic surgery. The titanium screws used in the orthopedic surgery that he underwent were removed 1 year later, but the eczema remained. After removal of dental implants, the eczema disappeared completely. Titanium is used not only for medical applications such as plastic surgery and/or dental implants, but also for paints, white pigments, photocatalysts, and various types of everyday goods. Most of the usage of titanium is in the form of titanium dioxide. This rapid expansion of titanium-containing products has increased percutaneous and permucosal exposure of titanium to the population. In general, allergic risk of titanium material is smaller than that of other metal materials. However, we suggest that pre-implant patients should be asked about a history of hypersensitivity reactions to metals, and patch testing should be recommended to patients who have experienced such reactions. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Endovascular Treatment in Emergency Setting of Acute Arterial Injuries After Orthopedic Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carrafiello, Gianpaolo, E-mail: gcarraf@tin.it; Fontana, Federico, E-mail: fede.fontana@libero.it; Mangini, Monica, E-mail: monica.mangini@tin.it

    Purpose: To assess the feasibility and effectiveness of emergency endovascular treatment of acute arterial injuries after orthopedic surgery. Materials and Methods: Fifteen patients (mean age 68.3 years) with acute arterial injuries after orthopedic surgery were observed, in particular, 5 patients with pseudoaneurysm, 9 patients with active bleeding, and 1 patient with arterial dissection. Transarterial embolization (TAE) and positioning of covered and noncovered stents were the treatments performed. Follow-up after stent implantation (mean 36 months) was performed with color Doppler US (CDU) at 1, 3, 6, and 12 months and yearly thereafter. Plain X-ray was performed to evidence dislodgment or fracturemore » of the graft. A minimum of 12 months' follow-up is available after TAE. Results: Immediate technical success was obtained in all cases. No major complications occurred. Overall clinical success rate was 100%. During mean follow-up, stent-graft occlusions did not occurred. No recurrence and/or consequence of TAE was registered during a minimum follow-up of 12 months. Conclusions: Percutaneous treatment is a feasible and safe tool for treating arterial injuries because it can provide fast and definitive resolution of the damage. This low-invasiveness approach can be proposed as first-line treatment in patients with acute injuries after orthopedic surgery.« less

  19. The Use of Finite Element Analysis to Enhance Research and Clinical Practice in Orthopedics.

    PubMed

    Pfeiffer, Ferris M

    2016-02-01

    Finite element analysis (FEA) is a very powerful tool for the evaluation of biomechanics in orthopedics. Finite element (FE) simulations can effectively and efficiently evaluate thousands of variables (such as implant variation, surgical techniques, and various pathologies) to optimize design, screening, prediction, and treatment in orthopedics. Additionally, FEA can be used to retrospectively evaluate and troubleshoot complications or failures to prevent similar future occurrences. Finally, FE simulations are used to evaluate implants, procedures, and techniques in a time- and cost-effective manner. In this work, an overview of the development of FE models is provided and an example application is presented to simulate knee biomechanics for a specimen with medial meniscus insufficiency. FE models require the development of the geometry of interest, determination of the material properties of the tissues simulated, and an accurate application of a numerical solver to produce an accurate solution and representation of the field variables. The objectives of this work are to introduce the reader to the application of FEA in orthopedic analysis of the knee joint. A brief description of the model development process as well as a specific application to the investigation of knee joint stability in geometries with normal or compromised medial meniscal attachment is included. Significant increases in stretch of the anterior cruciate ligament were predicted in specimens with medial meniscus insufficiency (such behavior was confirmed in corresponding biomechanical testing). It can be concluded from this work that FE analysis of the knee can provide significant new information with which more effective clinical decisions can be made. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. Mentorship in Orthopedics: A National Survey of Orthopedic Surgery Residents.

    PubMed

    Oladeji, Lasun O; Ponce, Brent A; Worley, John R; Keeney, James A

    2018-04-24

    Mentorship is an important component of graduate medical education. It has been associated with numerous benefits including personal development, increased career satisfaction, and reduced stress and burnout. The purpose of this study was to assess orthopedic resident attitudes regarding mentorship and to determine if there were sociodemographic differences. A total of 243 orthopedic surgery residents completed this 25-item mixed response questionnaire. Nearly two-thirds of residents conveyed that their training program either had a formal or informal mentorship program, and 95.8% of residents indicated that they believed mentorship played an important role with respect to their development as an orthopedic resident. Minorities were more likely to have a mentor that was obtained while they were in medical school, less likely to have multiple mentors, and more likely to be dissatisfied with the quality of mentorship in residency. Females were more likely to pursue a mentor on their own. Overall, 31% of orthopedic residents were classified as experiencing burnout. There was no difference in the prevalence of mentorship in respondents experiencing burnout, but they were more likely to be unsatisfied with the quality of mentorship in residency. Finally, only two-thirds of residency programs have mentorship programs despite the fact that the vast majority of orthopedic residents believe that the mentorship plays an important role in their development as surgeons. Given these findings, future work should focus on identifying and addressing race and sex-based mentorship disparities while simultaneously working to improve access to mentorship for all residents. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  1. Bactericidal micron-thin sol-gel films prevent pin tract and periprosthetic infection.

    PubMed

    Qu, Haibo; Knabe, Christine; Burke, Megan; Radin, Shula; Garino, Jonathan; Schaer, Thomas; Ducheyne, Paul

    2014-08-01

    Orthopedic injuries constitute the majority of wounds sustained by U.S. soldiers in recent conflicts. The risk of infection is considerable with fracture fixation devices. In this pilot study, we examined the use of unique bactericidal micron-thin sol-gel films on fracture fixation devices and their ability to prevent and eradicate infections. External fixation was studied with micron-thin sol-gel coated percutaneous pins releasing triclosan and inserted medially into rabbit tibiae. A total of 11 rabbits received percutaneous pins that were either uncoated or sol-gel/triclosan coated. Internal fracture fixation was also studied using sol-gel coated intramedullary (IM) nails releasing vancomycin in the intramedullary tibiae. Six sheep received IM nails that were coated with a sol-gel film that either contained vancomycin or did not contain vancomycin. All animals were challenged with Staphylococcus aureus around the implant. Animals were euthanized at 1 month postoperative. Rabbits receiving triclosan/sol-gel coated percutaneous pins did not show signs of infection. Uncoated percutaneous pins had a significantly higher infection rate. In the sheep study, there were no radiographic signs of osteomyelitis with vancomycin/sol-gel coated IM nails, in contrast to the observations in the control cohort. Hence, the nanostructured sol-gel controlled release technology offers the promise of a reliable and continuous delivery system of bactericidals from orthopedic devices to prevent and treat infection. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  2. Lithium chloride enhances bone regeneration and implant osseointegration in osteoporotic conditions.

    PubMed

    Jin, Yifan; Xu, Lihua; Hu, Xiaohui; Liao, Shixian; Pathak, Janak L; Liu, Jinsong

    2016-10-06

    Osteoporotic patients have a high risk of dental and orthopedic implant failure. Lithium chloride (LiCl) has been reported to enhance bone formation. However, the role of LiCl in the success rate of dental and orthopedic implants in osteoporotic conditions is still unknown. We investigated whether LiCl enhances implant osseointegration, implant fixation, and bone formation in osteoporotic conditions. Sprague-Dawley female rats (n = 18) were ovariectomized (OVX) to induce osteoporosis, and another nine rats underwent sham surgery. Three months after surgery, titanium implants were implanted in the tibia of the OVX and sham group rats. After implantation, the OVX rats were gavaged with 150 mg/kg/2 days of LiCl (OVX + LiCl group) or saline (OVX group), and sham group rats were gavaged with saline for 3 months. Implant osseointegration and bone formation were analyzed using histology, biomechanical testing, and micro computed tomography (micro-CT). More bone loss was observed in the OVX group compared to the control, and LiCl treatment enhanced bone formation and implant fixation in osteoporotic rats. In the OVX group, bone-implant contact (BIC) was decreased by 81.2 % compared to the sham group. Interestingly, the OVX + LiCl group showed 4.4-fold higher BIC compared to the OVX group. Micro-CT data of tibia from the OVX + LiCl group showed higher bone volume, trabecular thickness, trabecular number, and osseointegration compared to the OVX group. Maximum push-out force and implant-bone interface shear strength were 2.9-fold stronger in the OVX + LiCl group compared to the OVX group. In conclusion, LiCl enhanced implant osseointegration, implant fixation, and bone formation in osteoporotic conditions, suggesting LiCl as a promising therapeutic agent to prevent implant failure and bone loss in osteoporotic conditions.

  3. Molecular & phenotypic characterization of Staphylococcus epidermidis in implant related infections

    PubMed Central

    Prasad, Sujata; Nayak, N.; Satpathy, G.; Nag, H.L.; Venkatesh, P.; Ramakrishnan, S.; Ghose, Supriyo; Nag, T.C.

    2012-01-01

    Background & objectives: The discrimination between the Staphylococcus epidermidis colonizing the deep seated indwelling devices and those which are mere commensals has always been a challenge for the clinical microbiologist. This study was aimed to characterize the S. epidermidis isolates obtained from device related infection for their phenotypic and molecular markers of virulence and to see whether these markers can be used to differentiate the pathogenic S. epidermidis from the commensals. Methods: Fifty five S. epidermidis isolates from various device related infections such as endophthalmitis following intra-ocular lens (IOL) implantation, intravascular (IV) catheter related sepsis and orthopaedic implant infections, were studied for slime production, biotyping, antibiotic sensitivity; and mec A and ica positivity by the recommended procedures. Results: Twenty three (41.8%) isolates were multi-drug resistant, 26 (65.2%) were slime producers, 30 (54.5%) were adherent, 23 (41.8%) possessed the intercellular adhesin (ica) gene, and 28 (50.9%) harboured the mec A gene. Biotypes I and III were the commonest, most members of which were multi- drug resistant. Twenty two (73.3%) of the 30 adherent bacteria were slime producers as opposed to only 4 (16%) of the 25 non-adherent bacteria (P<0.001). A vast majority i.e. 21 (91.3%) of the 23 ica positive organisms were adherent to artificial surfaces in contrast to only 9 (28.1%) of the 32 non-ica positive organisms (P<0.001). Twenty (86.9%) of the 23 ica positive bacteria were slime producers, as opposed to only 6 (18.7%) of the 32 ica negative bacteria (P<0.001). Of the 23 multi-drug resistant isolates, 19 (82.6%) carried the mec A gene. Interpretation & conclusions: The present findings showed that ica AB and mec A were the two important virulence markers of S. epidermidis in implant infections and slime was responsible for the sessile mode of attachment on the devices. PMID:23041744

  4. Antibacterial activity and cytocompatibility of an implant coating consisting of TiO2 nanotubes combined with a GL13K antimicrobial peptide.

    PubMed

    Li, Tao; Wang, Na; Chen, Su; Lu, Ran; Li, Hongyi; Zhang, Zhenting

    2017-01-01

    Prevention of implant-associated infections at an early stage of surgery is highly desirable for the long-term efficacy of implants in dentistry and orthopedics. Infection prophylaxis using conventional antibiotics is becoming less effective due to the development of bacteria resistant to multiple antibiotics. An ideal strategy to conquer bacterial infections is the local delivery of antibacterial agents. Therefore, antimicrobial peptide (AMP) eluting coatings on implant surfaces is a promising alternative. In this study, the feasibility of utilizing TiO 2 nanotubes (TNTs), processed using anodization, as carriers to deliver a candidate AMP on titanium surfaces for the prevention of implant-associated infections is assessed. The broad-spectrum GL13K (GKIIKLKASLKLL-CONH2) AMP derived from human parotid secretory protein was selected and immobilized to TNTs using a simple soaking technique. Field emission scanning electron microscope, X-ray diffraction, Fourier transform infrared spectroscopy, and liquid chromatography-mass spectrometry analyses confirmed the successful immobilization of GL13K to anatase TNTs. The drug-loaded coatings demonstrated a sustained and slow drug release profile in vitro and eradicated the growth of Fusobacterium nucleatum and Porphyromonas gingivalis within 5 days of culture, as assessed by disk-diffusion assay. The GL13K-immobilized TNT (GL13K-TNT) coating demonstrated greater biocompatibility, compared with a coating produced by incubating TNTs with equimolar concentrations of metronidazole. GL13K-TNTs produced no observable cytotoxicity to preosteoblastic cells (MC3T3-E1). The coating may also have an immune regulatory effect, in support of rapid osseointegration around implants. Therefore, the combination of TNTs and AMP GL13K may achieve simultaneous antimicrobial and osteoconductive activities.

  5. Analysis of outpatient trauma referrals in a sub-Saharan African orthopedic center.

    PubMed

    Jergesen, Harry; Oloruntoba, David; Aluede, Edward; Grova, Monica; Phillips, Jonathan; Caldwell, Amber

    2011-05-01

    The purpose of this study was to characterize the orthopedic trauma workload in the Bedford Orthopaedic Centre (BOC), an orthopedic referral hospital in rural South Africa. Demographic data, injury data, and information about initial management were collected for two 6-week periods during both 2008 and 2009 from patients seen in the BOC outpatient department. Two primary outcomes were evaluated: (1) the interval between the initial outside evaluation and the BOC consultation and (2) the presence of established infection at the time of consultation. Secondary outcomes included assessments of the initial management at the referring facility. Most patients were adult men. Almost half were referred from within a radius of 10 km, but more than one-third came from facilities in excess of 50 km away. The most frequent mode of transport was ambulance followed by taxi-van. Fractures accounted for most of the injuries. Motor vehicle accidents and assaults were more prevalent among adults than among children, for whom falls accounted for a large proportion of injuries. Referral was delayed more than 72 h in 41.4% of patients. Established infections were identified in 12.2%. Deficiencies detected during prehospital care were common. The burden of orthopedic trauma in this rural referral center is sufficient to justify the manpower and resources needed for a major orthopedic trauma center. Because most of the injuries were fractures, efforts should be aimed at improving fracture care. Differences in the mode of injury and in the anatomical sites involved between adults and children highlight the need for focused preventive measures. Reducing both delays in referral and deficiencies in initial management might well reduce the cost and complexity of the definitive treatment required.

  6. [Local foreign body reactions to biodegradable implants. A classification].

    PubMed

    Hoffmann, R; Weller, A; Helling, H J; Krettek, C; Rehm, K E

    1997-08-01

    Biodegradable implants are increasingly used in orthopedic and trauma surgery. Many different implants consisting of different biodegradable polymers are currently available. Different factors contribute to the biocompatibility of these implants, and local foreign-body reactions remain a matter of concern. Therefore, it is mandatory to document and compare the tissue reactions caused by various biodegradable implants in experimental or clinical studies. We have developed a standardized system of classification based on our previous experimental and clinical observations. Foreign-body reactions are differentiated into osteolysis (0-0 to 0-4), extra-articular (EA-0 to EA-4) and intraarticular (IA-0 to A-4) soft-tissue reactions.

  7. Tantalum—A bioactive metal for implants

    NASA Astrophysics Data System (ADS)

    Balla, Vamsi Krishna; Bose, Susmita; Davies, Neal M.; Bandyopadhyay, Amit

    2010-07-01

    Metallic biomaterials currently in use for load-bearing orthopedic applications are mostly bioinert and therefore lack sufficient osseointegration. Although bioactive ceramics such as hydroxyapatite (HA) can spontaneously bond to living bone tissue, low fracture toughness of HA limits their use as a bone substitute for load-bearing applications. Surface modification techniques such as HA coating on metals are current options to improve osseointegration in load-bearing metal implants. Over the last few decades researchers have attempted to find a bioactive metal with high mechanical strength and excellent fatigue resistance that can bond chemically with surrounding bone for orthopedic applications. Recent in vitro, in vivo, and clinical studies demonstrated that tantalum is a promising metal that is bioactive. However, tantalum applications in biomedical devices have been limited by processing challenges rather than biological performances. In this article, we provide an overview of processing aspects and biological properties of tantalum for load-bearing orthopedic applications.

  8. (68)Ga-DOTA-Siglec-9 PET/CT imaging of peri-implant tissue responses and staphylococcal infections.

    PubMed

    Ahtinen, Helena; Kulkova, Julia; Lindholm, Laura; Eerola, Erkki; Hakanen, Antti J; Moritz, Niko; Söderström, Mirva; Saanijoki, Tiina; Jalkanen, Sirpa; Roivainen, Anne; Aro, Hannu T

    2014-01-01

    Staphylococcus epidermidis (S. epidermidis) has emerged as one of the leading pathogens of biomaterial-related infections. Vascular adhesion protein-1 (VAP-1) is an inflammation-inducible endothelial molecule controlling extravasation of leukocytes. Sialic acid-binding immunoglobulin-like lectin 9 (Siglec-9) is a leukocyte ligand of VAP-1. We hypothesized that (68)Ga-labeled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-conjugated Siglec-9 motif containing peptide ((68)Ga-DOTA-Siglec-9) could detect inflammatory response due to S. epidermidis peri-implant infection by positron emission tomography (PET). Thirty Sprague-Dawley rats were randomized into three groups. A sterile catheter was implanted into the medullary canal of the left tibia. In groups 1 and 2, the implantation was followed by peri-implant injection of S. epidermidis or Staphylococcus aureus (S. aureus) with adjunct injections of aqueous sodium morrhuate. In group 3, sterile saline was injected instead of bacteria and no aqueous sodium morrhuate was used. At 2 weeks after operation, (68)Ga-DOTA-Siglec-9 PET coupled with computed tomography (CT) was performed with the measurement of the standardized uptake value (SUV). The presence of the implant-related infection was verified by microbiological analysis, imaging with fluorescence microscope, and histology. The in vivo PET results were verified by ex vivo measurements by gamma counter. In group 3, the tibias with implanted sterile catheters showed an increased local uptake of (68)Ga-DOTA-Siglec-9 compared with the intact contralateral bones (SUVratio +29.5%). (68)Ga-DOTA-Siglec-9 PET detected inflammation induced by S. epidermidis and S. aureus catheter-related bone infections (SUVratio +58.1% and +41.7%, respectively). The tracer uptake was significantly higher in the S. epidermidis group than in group 3 without bacterial inoculation, but the difference between S. epidermidis and S. aureus groups was not statistically significant. The

  9. 68Ga-DOTA-Siglec-9 PET/CT imaging of peri-implant tissue responses and staphylococcal infections

    PubMed Central

    2014-01-01

    Background Staphylococcus epidermidis (S. epidermidis) has emerged as one of the leading pathogens of biomaterial-related infections. Vascular adhesion protein-1 (VAP-1) is an inflammation-inducible endothelial molecule controlling extravasation of leukocytes. Sialic acid-binding immunoglobulin-like lectin 9 (Siglec-9) is a leukocyte ligand of VAP-1. We hypothesized that 68Ga-labeled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-conjugated Siglec-9 motif containing peptide (68Ga-DOTA-Siglec-9) could detect inflammatory response due to S. epidermidis peri-implant infection by positron emission tomography (PET). Methods Thirty Sprague-Dawley rats were randomized into three groups. A sterile catheter was implanted into the medullary canal of the left tibia. In groups 1 and 2, the implantation was followed by peri-implant injection of S. epidermidis or Staphylococcus aureus (S. aureus) with adjunct injections of aqueous sodium morrhuate. In group 3, sterile saline was injected instead of bacteria and no aqueous sodium morrhuate was used. At 2 weeks after operation, 68Ga-DOTA-Siglec-9 PET coupled with computed tomography (CT) was performed with the measurement of the standardized uptake value (SUV). The presence of the implant-related infection was verified by microbiological analysis, imaging with fluorescence microscope, and histology. The in vivo PET results were verified by ex vivo measurements by gamma counter. Results In group 3, the tibias with implanted sterile catheters showed an increased local uptake of 68Ga-DOTA-Siglec-9 compared with the intact contralateral bones (SUVratio +29.5%). 68Ga-DOTA-Siglec-9 PET detected inflammation induced by S. epidermidis and S. aureus catheter-related bone infections (SUVratio +58.1% and +41.7%, respectively). The tracer uptake was significantly higher in the S. epidermidis group than in group 3 without bacterial inoculation, but the difference between S. epidermidis and S. aureus groups was not statistically

  10. Characteristics of highly successful orthopedic surgeons: a survey of orthopedic chairs and editors

    PubMed Central

    Klein, Guy; Hussain, Nasir; Sprague, Sheila; Mehlman, Charles T.; Dogbey, Godwin; Bhandari, Mohit

    2013-01-01

    Background Highly successful orthopedic surgeons are a small group of individuals who exert a large influence on the orthopedic field. However, the characteristics of these leaders have not been well-described or studied. Methods Orthopedic surgeons who are departmental chairs, journal editors, editorial board members of the Journal of Bone and Joint Surgery (British edition), or current or past presidents of major orthopedic associations were invited to complete a survey designed to provide insight into their motivations, academic backgrounds and accomplishments, emotional and physical health, and job satisfaction. Results In all, 152 surgeons completed the questionnaire. We identified several characteristics of highly successful surgeons. Many have contributed prolific numbers of publications and book chapters and obtained considerable funding for research. They were often motivated by a “desire for personal development (interesting challenge, new opportunities),” whereas “relocating to a new institution, financial gain, or lack of alternative candidates” played little to no role in their decisions to take positions of leadership. Most respondents were happy with their specialty choice despite long hours and high levels of stress. Despite challenges to their time, successful orthopedic surgeons made a strong effort to maintain their health; compared with other physicians, they exercise more, are more likely to have a primary care physician and feel better physically. Conclusion Departmental chairs, journal editors and presidents of orthopedic associations cope with considerable demands of clinical, administrative, educational and research duties while maintaining a high level of health, happiness and job satisfaction. PMID:23706848

  11. Development of a Hybrid Tracer for SPECT and Optical Imaging of Bacterial Infections.

    PubMed

    Welling, Mick M; Bunschoten, Anton; Kuil, Joeri; Nelissen, Rob G H H; Beekman, Freek J; Buckle, Tessa; van Leeuwen, Fijs W B

    2015-05-20

    In trauma and orthopedic surgery, infection of implants has a major impact on the outcome for patients. Infections may develop either during the initial implantation or during the lifetime of an implant. Both infections, as well as aseptic loosening of the implant, are reasons for revision of the implants. Therefore, discrimination between aseptic-mechanical-loosening and septic-bacterial-loosening of implants is critical during selection of a patient-tailored treatment policy. Specific detection and visualization of infections is a challenge because it is difficult to discriminate infections from inflammation. An imaging tracer that facilitates bacterial identification in a pre- and intraoperative setting may aid the workup for patients suspicious of bacterial infections. In this study we evaluated an antimicrobial peptide conjugated to a hybrid label, which contains both a radioisotope and a fluorescent dye. After synthesis of DTPA-Cy5-UBI29-41 and-when necessary-radiolabeling with (111)In (yield 96.3 ± 2.7%), in vitro binding to various bacterial strains was evaluated using radioactivity counting and confocal fluorescence microscopy. Intramuscular bacterial infections (S. aureus or K. pneumoniae) were also visualized in vivo using a combined nuclear and fluorescence imaging system. The indium-111 was chosen as label as it has a well-defined coordination chemistry, and in pilot studies labeling DTPA-Cy5-UBI29-41 with technetium-99m, we encountered damage to the Cy5 dye after the reduction with SnCl2. As a reference, we used the validated tracer (99m)Tc-UBI29-41. Fast renal excretion of (111)In-DTPA-Cy5-UBI29-41 was observed. Target to nontarget (T/NT) ratios were highest at 2 h post injection: radioactivity counting yielded T/NT ratios of 2.82 ± 0.32 for S. aureus and 2.37 ± 0.05 for K. pneumoniae. Comparable T/NT ratios with fluorescence imaging of 2.38 ± 0.09 for S. aureus and 3.55 ± 0.31 for K. pneumoniae were calculated. Ex vivo confocal microscopy of

  12. Medical photography: principles for orthopedics.

    PubMed

    Uzun, Metin; Bülbül, Murat; Toker, Serdar; Beksaç, Burak; Kara, Adnan

    2014-04-05

    Medical photography is used clinically for patient evaluation, treatment decisions, and scientific documentation. Although standards for medical photography exist in many branches of medicine, we have not encountered such criteria in publications in the area of orthopedics. This study aims to (1) assess the quality of medical images used in an orthopedic publication and (2) to propose standards for medical photography in this area. Clinical photographs were reviewed from all issues of a journal published between the years 2008 and 2012. A quality of clinical images was developed based on the criteria published for the specialties of dermatology and cosmetic surgery. All images were reviewed on the appropriateness of background, patient preparation, and technique. In this study, only 44.9% of clinical images in an orthopedic publication adhered to the proposed conventions. Standards have not been established for medical photography in orthopedics as in other specialty areas. Our results suggest that photographic clinical information in orthopedic publications may be limited by inadequate presentation. We propose that formal conventions for clinical images should be established.

  13. Does Extracellular DNA Production Vary in Staphylococcal Biofilms Isolated From Infected Implants versus Controls?

    PubMed

    Zatorska, Beata; Groger, Marion; Moser, Doris; Diab-Elschahawi, Magda; Lusignani, Luigi Segagni; Presterl, Elisabeth

    2017-08-01

    Prosthetic implant infections caused by Staphylococcus aureus and epidermidis are major challenges for early diagnosis and treatment owing to biofilm formation on the implant surface. Extracellular DNA (eDNA) is actively excreted from bacterial cells in biofilms, contributing to biofilm stability, and may offer promise in the detection or treatment of such infections. (1) Does DNA structure change during biofilm formation? (2) Are there time-dependent differences in eDNA production during biofilm formation? (3) Is there differential eDNA production between clinical and control Staphylococcal isolates? (4) Is eDNA production correlated to biofilm thickness? We investigated eDNA presence during biofilm formation in 60 clinical and 30 control isolates of S aureus and S epidermidis. The clinical isolates were isolated from patients with infections of orthopaedic prostheses and implants: 30 from infected hip prostheses and 30 from infected knee prostheses. The control isolates were taken from healthy volunteers who had not been exposed to antibiotics and a hospital environment during the previous 3 and 12 months, respectively. Control S epidermidis was isolated from the skin of the antecubital fossa, and control S aureus was isolated from the nares. For the biofilm experiments the following methods were used to detect eDNA: (1) fluorescent staining with 4',6-diamidino-2-phenylindole (DAPI), (2) eDNA extraction using a commercial kit, and (3) confocal laser scanning microscopy for 24-hour biofilm observation using propidium iodide and concanavalin-A staining; TOTO ® -1 and SYTO ® 60 staining were used for observation and quantification of eDNA after 6 and 24 hours of biofilm formation. Additionally antibiotic resistance was described. eDNA production as observed by confocal laser scanning microscopy was greater in clinical isolates than controls (clinical isolates mean ± SD: 1.84% ± 1.31%; control mean ± SD: 1.17% ± 1.37%; p < 0.005) after 6 hours of biofilm

  14. Osseous adaptation to continuous loading of rigid endosseous implants

    NASA Technical Reports Server (NTRS)

    Roberts, W. E.; Smith, R. K.; Mozsary, P. G.; Zilberman, Y.; Smith, R. S.

    1984-01-01

    The effect of loading on etched Ti implants in the femurs of young (3 mo) and adult (6 mo) rabbits is investigated experimentally. The results are presented in photographs, fluorescence and polarization micrographs, radiographs, and drawings and discussed. Implantation is followed by formation of coarse woven bone within 3 d and mature lamellar bone by 6 wks, with nonspecific subperiosteal bony hypertrophy in the young rabbits only. Spring loading at 100 g produces spontaneous spiral-type fractures when applied immediately, but the implants remain rigid when loads are applied after 6-12 wks of healing. The mechanisms of bone formation involved are examined, and the potential of endosseous implants as anchors in orthodontics or dentofacial-orthopedics is confirmed.

  15. Mechanical Behavior of Polymer Nano Bio Composite for Orthopedic Implants

    NASA Astrophysics Data System (ADS)

    Marimuthu, K., Dr.; Rajan, Sankar

    2018-04-01

    The bio-based polymer composites have been the focus of many scientific and research projects, as well as many commercial programs. In recent years, scientists and engineers have been working together to use the inherent strength and performance of the new class of bio-based composites which is compactable with human body and can act as a substitute for living cells. In this stage the polymer composites also stepped into human bone implants as a replacement for metallic implants which was problems like corrosion resistance and high cost. The polymer composite have the advantage that it can be molded to the required shape, the polymers have high corrosion resistance, less weight and low cost. The aim of this research is to develop and analyze the suitable bio compactable polymer composite for human implants. The nano particles reinforced polymer composites provides good mechanical properties and shows good tribological properties especially in the total hip and knee replacements. The graphene oxide powders are bio compactable and acts as anti biotic. GO nano powder where reinforced into High-density polyethylene in various weight percentage of 0.5% to 2%. The performance of GO nano powder shows better tribological properties. The material produced does not cause any pollution to the environment and at the same time it can be bio compactable and sustainable. The product will act environmentally friendly.

  16. Billing and coding knowledge: a comparative survey of professional coders, practicing orthopedic surgeons, and orthopedic residents.

    PubMed

    Wiley, Kevin F; Yousuf, Tariq; Pasque, Charles B; Yousuf, Khalid

    2014-06-01

    Medical knowledge and surgical skills are necessary to become an effective orthopedic surgeon. To run an efficient practice, the surgeon must also possess a basic understanding of medical business practices, including billing and coding. In this study, we surveyed and compared the level of billing and coding knowledge among current orthopedic residents PGY3 and higher, academic and private practice attending orthopedic surgeons, and orthopedic coding professionals. According to the survey results, residents and fellows have a similar knowledge of coding and billing, regardless of their level of training or type of business education received in residency. Most residents would like formal training in coding, billing, and practice management didactics; this is consistent with data from previous studies.

  17. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    PubMed Central

    Landgraeber, Stefan; Jäger, Marcus; Jacobs, Joshua J.; Hallab, Nadim James

    2014-01-01

    All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older people (>75 yrs) of total joint replacement revision surgery. In some people implant debris (particles and ions from metals) can influence the adaptive immune system as well, giving rise to the concept of metal sensitivity. However, a consensus of studies agrees that the dominant form of this response is due to innate reactivity by macrophages to implant debris where both danger (DAMP) and pathogen (PAMP) signalling elicit cytokine-based inflammatory responses. This paper discusses implant debris induced release of the cytokines and chemokines due to activation of the innate (and the adaptive) immune system and the subsequent formation of osteolysis. Different mechanisms of implant-debris reactivity related to the innate immune system are detailed, for example, danger signalling (e.g., IL-1β, IL-18, IL-33, etc.), toll-like receptor activation (e.g., IL-6, TNF-α, etc.), apoptosis (e.g., caspases 3–9), bone catabolism (e.g., TRAP5b), and hypoxia responses (Hif1-α). Cytokine-based clinical and basic science studies are in progress to provide diagnosis and therapeutic intervention strategies. PMID:24891761

  18. Characterization of cell cultures in contact with different orthopedic implants biomaterials

    NASA Astrophysics Data System (ADS)

    Ouenzerfi, G.; Hannoun, A.; Hassler, M.; Brizuela, L.; Youjil, S.; Bougault, C.; Trunfio-Sfarghiu, A.-M.

    2016-08-01

    The aim of this study is to identify the role of biological and mechanical constraints (at the cellular level) surrounding living tissues (cartilage and bone) in the presence of different joint implant biomaterials. In this fact, cells cultures in the presence of different types of biomaterials (pyrolytic carbon, cobalt-Chromium, titanium) has been performed. These cell cultures were subjected to biological characterization tests and mechanical characterization. The obtained results correlate with the in vivo observations (a promotion of the creation of a neocartilagical tissue in contact with the Pyrolytic Carbon implants).

  19. The use of antimicrobial-impregnated PMMA to manage periprosthetic infections: controversial issues and the latest developments.

    PubMed

    Tan, H L; Lin, W T; Tang, T T

    2012-10-01

    Despite improvements in intraoperative antimicrobial procedures, in surgical techniques and in implant design for joint replacement, periprosthetic infection after arthroplasty is still one of the most challenging problems encountered by orthopedic surgeons. Systemic antibiotics are not sufficiently effective to eradicate such deep infections because of the impaired blood circulation and low antibiotic concentration at the implantation site. As a local drug delivery system, antibiotic-impregnated PMMA (polymethylmethacrylate) bone cements have been widely used for prophylaxis or treatment of deep infections after total joint replacement. However, the effectiveness of antibiotic-loaded PMMA in preventing infections after arthroplasty is still controversial. Furthermore, the outcomes of established deep infections treated with this technique are not consistent. The local use of antibiotics has led to the emergence of antibiotic-resistant bacterial strains and has adverse effects on the function of osteogenic cells. Recently, many efforts have been made to identify new antibacterial agents that can be loaded into PMMA. These antimicrobial agents should exhibit good antibacterial activity against antibiotic-resistant strains and should simultaneously enhance osteointegration between the PMMA and the bone tissue. PMMA loaded with chitosan or chitosan derivatives has been demonstrated to induce improved osteogenic activity and to exhibit antibacterial activity in a preclinical study.

  20. In Vivo Assessment of Phage and Linezolid Based Implant Coatings for Treatment of Methicillin Resistant S. aureus (MRSA) Mediated Orthopaedic Device Related Infections

    PubMed Central

    Kaur, Sandeep; Harjai, Kusum; Chhibber, Sanjay

    2016-01-01

    Staphylococcus comprises up to two-thirds of all pathogens in orthopaedic implant infections with two species respectively Staphylococcus aureus and Staphylococcus epidermidis, being the predominate etiological agents isolated. Further, with the emergence of methicillin-resistant S. aureus (MRSA), treatment of S. aureus implant infections has become more difficult, thus representing a devastating complication. Use of local delivery system consisting of S.aureus specific phage along with linezolid (incorporated in biopolymer) allowing gradual release of the two agents at the implant site represents a new, still unexplored treatment option (against orthopaedic implant infections) that has been studied in an animal model of prosthetic joint infection. Naked wire, hydroxypropyl methylcellulose (HPMC) coated wire and phage and /or linezolid coated K-wire were surgically implanted into the intra-medullary canal of mouse femur bone of respective groups followed by inoculation of S.aureus ATCC 43300(MRSA). Mice implanted with K-wire coated with both the agents i.e phage as well as linezolid (dual coated wires) showed maximum reduction in bacterial adherence, associated inflammation of the joint as well as faster resumption of locomotion and motor function of the limb. Also, all the coating treatments showed no emergence of resistant mutants. Use of dual coated implants incorporating lytic phage (capable of self-multiplication) as well as linezolid presents an attractive and aggressive early approach in preventing as well as treating implant associated infections caused by methicillin resistant S. aureus strains as assessed in a murine model of experimental joint infection. PMID:27333300

  1. An Overview of the History of Orthopedic Surgery.

    PubMed

    Swarup, Ishaan; O'Donnell, Joseph F

    Orthopedic surgery has a long and rich history. While the modern term orthopedics was coined in the 1700s, orthopedic principles were beginning to be developed and used during primitive times. The Egyptians continued these practices, and described ways to recognize and manage common orthopedic conditions. The Greeks and Romans subsequently began to study medicine in a systematic manner, and greatly improved our understanding of orthopedic anatomy and surgical technique. After a period of little progress during the Middle Ages, rapid advancement was noted during the Renaissance, including the description of various injuries, improvements in surgical technique, and development of orthopedic hospitals. Collectively, these advances provided the foundation for modern orthopedics. Currently, orthopedic surgery is a rapidly developing field that has benefited from the works of numerous scholars and surgeons. It is important to recognize the successes and failures of the past, in order to advance research and practice as well as improve patient care and clinical outcomes.

  2. Hardware-related infections after deep brain stimulation surgery: review of incidence, severity and management in 212 single-center procedures in the first year after implantation.

    PubMed

    Piacentino, Massimo; Pilleri, Manuela; Bartolomei, Luigi

    2011-12-01

    Device-related infection is a common occurrence after deep brain stimulation (DBS) surgery, and may result in additional interventions and a loss of efficacy of therapy. This retrospective review aimed to evaluate the incidence, severity and management of device-related infections in 212 DBS procedures performed in our institute. Data on 106 patients, in whom 212 DBS procedures were performed between 2001 and 2011 at our institute by a single neurosurgeon (M.P.), were reviewed to assess the incidence, severity, management and clinical characteristics of infections in the first year after the implantation of a DBS system. Infections occurred in 8.5% of patients and 4.2% of procedures. Of the nine infections, eight involved the neurostimulator and extensions, and one the whole system. The infections occurred 30.7 days after implantation: 7 within 30 days and 2 within 6 months. Infected and uninfected patients were comparable in terms of age, sex, indication for DBS implantation and neurostimulator location. In eight cases, the system components involved were removed and re-implanted after 3 months, while in one case the complete hardware was removed and not re-implanted. The overall incidence of postoperative infections after DBS system implantation was 4.2%; this rate decreased over time. All infections required further surgery. Correct and timely management of partial infections may result in successful salvage of part of the system.

  3. Scintigraphy of infected total hip arthroplasty (THA): A canine model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merkel, K.D.; Brown, M.L.; Fitzgerald, R.H.

    1984-01-01

    Differentiating low-grade sepsis from aseptic loosening of an orthopedic prosthesis is difficult. This study was designed to compare the ability of Tc-99m-HMDP, Ga-67, and In-111 leukocytes (WC) to differentiate low-grade sepsis from aseptic THA component loosening in a canine model. A canine THA was implanted in 14 dogs. Six dogs were given infected femoral components by injecting 10/sup 5/ colony-forming units of Staphylococcus aureus into the femoral canal 6y0 to 90 seconds prior to cementing. Four dogs had an aseptic loose femoral component, and four dogs had an aseptic tight femoral component (control). At six months all dogs were evaluatedmore » with X-ray, lab scintigraphy, and tissue quantitation of each tracer. Diagnosis was confirmed by histology and quantitative microbiology. White blood cell counts and differentials were normal in all dogs, and in only one out of six infected dogs was the sedimentation rate abnormal. X-rays were interpreted as possible infection in five dogs and probable infection in only one dog. In-111 WBC scans were more accurate than sequential Tc-Ga scans (sensitivity 94% vs 61%, specificity 86% vs 71% accuracy 90% vs 67%). Quantitative counting of gamma camera data and tissue samples demonstrated significantly (P < .01) higher accumulation of In-111 WBC about the infected than the loose or control component. No significant difference was demonstrated between the loose and septic components with TC-HMDP or Ga. These results correlate well and confirm our clinical data that In-111 WBC scanning is accurate and useful in the workup of the painful orthopedic prosthesis.« less

  4. An Overview of Internal Fixation Implant Metallurgy and Galvanic Corrosion Effects.

    PubMed

    Koh, Justin; Berger, Aaron; Benhaim, Prosper

    2015-08-01

    Orthopedic and hand surgery implants for internal fixation of fractures have evolved substantially over the past 50 years. Newer metal compositions have been used, and new standards have been applied to older alloys, resulting in modern implants with unique physical properties and better clinical performances. Conventional wisdom has long dictated that implanting different metals should be avoided, but few guidelines exist regarding the safety of using in proximity implant systems of dissimilar metals. To better characterize the landscape of internal fixation implant metallurgy, we have compiled the recommendations and conclusions of the currently available and pertinent literature. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Costimulatory molecule expression following exposure to orthopaedic implants wear debris.

    PubMed

    Bainbridge, J A; Revell, P A; Al-Saffar, N

    2001-03-05

    Patients with long-term orthopedic implants may develop inflammatory reactions due to the accumulation of biomaterial particles both around the implant and in distant organs. The exact impact of these particles on the normal immune cell function still remain relatively unclear. Activation of T-cells following exposure to biomaterial particles is driven by macrophages and requires synergistic signals primed by both antigen presentation and costimulation. The pattern of costimulatory molecule expression (CD80,CD86) was primarily examined using immunohistochemistry on tissue specimens of bone/implant interface membranes taken from sites of bone erosion. Additionally, costimulatory molecule expression was also assessed in the monocytic leukemia cell line U937 following exposure to clinically relevant titanium aluminum vanadium (TiAlV) and stainless steel particles (FeCrNi) cultured in vitro. This study demonstrates the induction and prominent expression of CD86 on almost all macrophage subsets at the bone/implant interface, including fused forms and large multinucleated giant cells (MNGC). In vitro analysis also indicated phagocytosis of metal particles by differentiated U937 caused significant induction of both CD80 and CD86 (p < 0.01), although the expression of CD86 dominated following prolonged exposure. The data presented highlights that CD86 is the predominant costimulatory molecule ligating to the complementary CD28 molecule at the inflammatory lesion of the interface. We propose that the intracellular presence of indigestible implant material, in addition to elevated costimulatory molecule expression, may promote T-cell inflammatory reactions at sites close to and distant from the orthopedic implant.

  6. A cardiac implantable device infection by Raoultella planticola in an immunocompromized patient.

    PubMed

    Adjodah, Chandra; D'Ivernois, Chistophe; Leyssene, David; Berneau, Jean-Baptiste; Hemery, Yann

    2017-02-01

    Introduction. Infection of cardiac implantable electronic devices is a severe condition associated with high mortality, particularly in patients who are dependent upon heart-pacing devices. Staphylococci are found in 70 % of reported cases. Case presentation. We report the case of a cardiac-pacemaker infection in a 79-year-old man, cumulating a history of rheumatoid arthritis treated by corticosteroids and methotrexate by a recently identified micro-organism: Raoultella planticola . He presented local signs of infection on his VVI pacemaker implantation site and underwent urgent pocket device replacement under cefamandole antibioprophylaxis. On incision thick pus oozed out. It was necessary to perform a complete hardware extraction comprising the pulse generator and the ancient lead. Pus was inoculated into aerobic and anaerobic culture vials and Gram staining unveiled Gram-negative rods. Microbiology analysis identified the organism as R. planticola. A new pacing device was inserted on the contrlateral pectoral region. Ciprofloxacin enabled full recovery. A literature review concerning this pathogen revealed that it is involved in severe infections such as bloodstream infections, peritonitis, cellulitis, pneumonia and lung abscesses, and urinary tract infections. In these case reports, underlying co-morbidities were identified such as solid active neoplasia, recent chemotherapy, corticosteroids, solid-organ-recipient patients and recent open surgery. Conclusion. R. planticola is a serious emerging pathogen and contributes to the burden of various infectious conditions. Its pathogenicity and occurrence should be known by clinicians and a high level of awareness is necessary to precisely identify it provide the correct antibiotic regimen.

  7. Infective endocarditis following Melody valve implantation: comparison with a surgical cohort.

    PubMed

    O'Donnell, Clare; Holloway, Rhonda; Tilton, Elizabeth; Stirling, John; Finucane, Kirsten; Wilson, Nigel

    2017-03-01

    Infective endocarditis has been reported post Melody percutaneous pulmonary valve implant; the incidence and risk factors, however, remain poorly defined. We identified four cases of endocarditis from our first 25 Melody implants. Our aim was to examine these cases in the context of postulated risk factors and directly compare endocarditis rates with local surgical valves. We conducted a retrospective review of patients post Melody percutaneous pulmonary valve implant in New Zealand (October, 2009-May, 2015) and also reviewed the incidence of endocarditis in New Zealand among patients who have undergone surgical pulmonary valve implants. In total, 25 patients underwent Melody implantation at a median age of 18 years. At a median follow-up of 2.9 years, most were well with low valve gradient (median 27 mmHg) and only mild regurgitation. Two patients presented with life-threatening endocarditis and obstructive vegetations at 14 and 26 months post implant, respectively. Two additional patients presented with subacute endocarditis at 5.5 years post implant. From 2009 to May, 2015, 178 surgical pulmonic bioprostheses, largely Hancock valves and homografts, were used at our institution. At a median follow-up of 2.9 years, four patients (2%) had developed endocarditis in this group compared with 4/25 (16%) in the Melody group (p=0.0089). Three surgical valves have been replaced. The Melody valve offers a good alternative to surgical conduit replacement in selected patients. Many patients have excellent outcomes in the medium term. Endocarditis, however, can occur and if associated with obstruction can be life threatening. The risk for endocarditis in the Melody group was higher in comparison with that in a contemporaneous surgical pulmonary implant cohort.

  8. A multi-scaled hybrid orthopedic implant: bone ECM-shaped Sr-HA nanofibers on the microporous walls of a macroporous titanium scaffold.

    PubMed

    Han, Yong; Zhou, Jianhong; Zhang, Lan; Xu, Kewei

    2011-07-08

    We report here, for the first time, a novel multi-scaled hybrid orthopedic implant material consisting of a macroporous Ti scaffold, whose macropores' walls have a microporous titania layer which is fully covered with nanofibers of Sr-doped hydroxyapatite (Sr-HA). The microporous titania layer is formed on and within the Ti scaffold by micro-arc oxidation, which firmly binds to the Ti substrate and contains Ca2+, Sr2+ and PO4(3-) ions. It is then hydrothermally treated to form Sr-HA nanofibers. During the hydrothermal treatment, Sr-HA nanoprisms nucleate from Ca0.5Sr0.5TiO3 pre-formed on the TiO2 and grow in length to nanofibers at the expense of Ca2+, Sr2+ and PO4(3-) ions that migrate from the TiO2. These Sr-HA nanofibers construct a network structure similar to the hierarchical organization of bone extracellular matrix (ECM), and the resulting nanofibrous surface displays a firm adhesion to substrate, superhydrophilicity and apatite-inducing ability. The induced apatite prefers to nucleate on the basal-faceted surfaces of Sr-HA nanofibers. The nanofiber-walled scaffold has a great potential for load-bearing orthotopic use.

  9. A multi-scaled hybrid orthopedic implant: bone ECM-shaped Sr-HA nanofibers on the microporous walls of a macroporous titanium scaffold

    NASA Astrophysics Data System (ADS)

    Han, Yong; Zhou, Jianhong; Zhang, Lan; Xu, Kewei

    2011-07-01

    We report here, for the first time, a novel multi-scaled hybrid orthopedic implant material consisting of a macroporous Ti scaffold, whose macropores' walls have a microporous titania layer which is fully covered with nanofibers of Sr-doped hydroxyapatite (Sr-HA). The microporous titania layer is formed on and within the Ti scaffold by micro-arc oxidation, which firmly binds to the Ti substrate and contains Ca2 + , Sr2 + and PO43 - ions. It is then hydrothermally treated to form Sr-HA nanofibers. During the hydrothermal treatment, Sr-HA nanoprisms nucleate from Ca0.5Sr0.5TiO3 pre-formed on the TiO2 and grow in length to nanofibers at the expense of Ca2 + , Sr2 + and PO43 - ions that migrate from the TiO2. These Sr-HA nanofibers construct a network structure similar to the hierarchical organization of bone extracellular matrix (ECM), and the resulting nanofibrous surface displays a firm adhesion to substrate, superhydrophilicity and apatite-inducing ability. The induced apatite prefers to nucleate on the basal-faceted surfaces of Sr-HA nanofibers. The nanofiber-walled scaffold has a great potential for load-bearing orthotopic use.

  10. Study on application of aerospace technology to improve surgical implants

    NASA Technical Reports Server (NTRS)

    Johnson, R. E.; Youngblood, J. L.

    1982-01-01

    The areas where aerospace technology could be used to improve the reliability and performance of metallic, orthopedic implants was assessed. Specifically, comparisons were made of material controls, design approaches, analytical methods and inspection approaches being used in the implant industry with hardware for the aerospace industries. Several areas for possible improvement were noted such as increased use of finite element stress analysis and fracture control programs on devices where the needs exist for maximum reliability and high structural performance.

  11. A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality.

    PubMed

    Hoerth, Rebecca M; Katunar, María R; Gomez Sanchez, Andrea; Orellano, Juan C; Ceré, Silvia M; Wagermaier, Wolfgang; Ballarre, Josefina

    2014-02-01

    Permanent metal implants are widely used in human medical treatments and orthopedics, for example as hip joint replacements. They are commonly made of titanium alloys and beyond the optimization of this established material, it is also essential to explore alternative implant materials in view of improved osseointegration. The aim of our study was to characterize the implant performance of zirconium in comparison to titanium implants. Zirconium implants have been characterized in a previous study concerning material properties and surface characteristics in vitro, such as oxide layer thickness and surface roughness. In the present study, we compare bone material quality around zirconium and titanium implants in terms of osseointegration and therefore characterized bone material properties in a rat model using a multi-method approach. We used light and electron microscopy, micro Raman spectroscopy, micro X-ray fluorescence and X-ray scattering techniques to investigate the osseointegration in terms of compositional and structural properties of the newly formed bone. Regarding the mineralization level, the mineral composition, and the alignment and order of the mineral particles, our results show that the maturity of the newly formed bone after 8 weeks of implantation is already very high. In conclusion, the bone material quality obtained for zirconium implants is at least as good as for titanium. It seems that the zirconium implants can be a good candidate for using as permanent metal prosthesis for orthopedic treatments.

  12. In vitro characterizations of mesoporous hydroxyapatite as a controlled release delivery device for VEGF in orthopedic applications.

    PubMed

    Poh, Chye Khoon; Ng, Suxiu; Lim, Tee Yong; Tan, Hark Chuan; Loo, Joachim; Wang, Wilson

    2012-11-01

    Following bone implant surgery, prolonged ischemic conditions at the implant site often result in postsurgical complications like failure of osseointegration at the bone-implant interface which can lead to implant failure. Thus, restoration of the vascular supply is paramount to the proper development of the bone. High surface area mesostructured materials have been shown to be attractive candidates for bone regeneration to enhance cell adhesion and cell proliferation. This study uses hydroxyapatite, a naturally occurring mineral in the bone, fabricated to a range of suitable pore sizes, infused with vascular endothelial growth factor (VEGF), to be progressively released to stimulate revascularization. In this study, several characterizations including nitrogen adsorption analysis, Fourier-transformed infrared spectroscopy, X-ray diffraction, field emission scanning electron microscope, and transmission electron microscope were used to evaluate the synthesized mesoporous hydroxyapatite (MHA). The results showed that MHA can gradually release VEGF for enhancing revascularization, which is beneficial for orthopedic applications. Copyright © 2012 Wiley Periodicals, Inc.

  13. Implants for orthodontic anchorage

    PubMed Central

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  14. Propionibacterium acnes infection after shoulder surgery

    PubMed Central

    Kadler, Benjamin K.; Mehta, Saurabh S.; Funk, Lennard

    2015-01-01

    Propionibacterium acnes has been implicated as a cause of infection following shoulder surgery, may occur up to 2 years after the index operation and has been shown to be responsible for up to 56% of shoulder infections after orthopedic implant. Male patients within the population undergoing shoulder surgery are particularly at risk, especially if their shoulder surgery involved prosthesis or was posttraumatic. P. acnes infection can be difficult to diagnose clinically and laboratory techniques require prolonged and specialized cultures. Usual inflammatory markers are not raised in infection with this low virulence organism. Delayed diagnosis with P. acnes infection can result in significant morbidity prior to prosthesis failure. Early diagnosis of P. acnes infection and appropriate treatment can improve clinical outcomes. It is important to be aware of P. acnes infection in shoulder surgery, to evaluate risk factors, to recognize the signs of P. acnes infection, and to promptly initiate treatment. The signs and symptoms of P. acnes infection are described and discussed. Data were collected from PubMed™, Web of Science, and the NICE Evidence Healthcare Databases - AMED (Ovid), BNI (Ovid), CINAHL (EBSCO), Embase (Ovid), HMIC: DH-Data and Kings Fund (Ovid), Medline (Ovid), and PsycINFO (Ovid). The search terms used were “P. acnes,” “infection,” “shoulder,” and “surgery.” In this review, we summarize the current understanding of the prevention and management of P. acnes infection following shoulder surgery. PMID:26622132

  15. Client counseling in orthopedic emergencies.

    PubMed

    Brackenridge, S S; Kirby, B M; Johnson, S W

    1995-09-01

    Important client communication issues associated with most orthopedic emergencies are addressed. Information on client communication and support, providing a prognosis, discussing economic concerns, discharge planning, euthanasia, and client grief is presented. The issue of animal abuse as a cause of orthopedic emergencies also is examined.

  16. A preliminary report on the usage of an intracorporal antibiotic cast with synthetic high purity CaSO4 for the treatment of infected penile implant.

    PubMed

    Swords, Kelly; Martinez, Daniel R; Lockhart, Jorge L; Carrion, Rafael

    2013-04-01

    Currently, the surgical treatment of infected penile prostheses is complete removal and either immediate salvage procedure, which carries a significant infection risk, or delayed implantation. With delayed implantation the risk of infection is lower, but the patient loses penile length and width due to corporal fibrosis. We present our experience with the use of a novel temporary synthetic high purity calcium sulfate (SHPCaSO4) component that acts as a "spacer" at the time of removal of an infected prosthesis while providing constant delivery of local antibiotic elution to the infected area. Demonstrate that the use of a novel material, SHPCaSO4, can be an innovative way to bridge the gap between removal of an infected penile implant and delayed reimplantation. Two patients (Patient A and B) presented with pain and erythema and were found to have infected malleable penile prosthesis. Both underwent removal of all infected components, and sent for tissue culture. The SHPCaSO4 was mixed with vancomycin and tobramycin, allowed to set up for 5 minutes, and then injected into the corporal space followed by closure with 2-0 Vicryl sutures. The injected SHPCaSO4 was palpable in the penile shaft both proximally and distally, as an "intracorporal casts." Patients denied pain postoperatively. Delayed implantation occurred at 6 weeks for patient A. This went uneventful and a new three-piece inflatable implant was inserted. Patient B underwent salvage placement of right malleable implant at 15 weeks, and here significant corporal fibrosis was encountered. Patients have had no infection since their delayed implantation (mean follow-up 4 months). Data in reference to SHPCaSO4 shows that this product dissolves in approximately 4-6 weeks. This may account for the difference in the ease of delayed implantation between the two patients. Further investigation is warranted. © 2013 International Society for Sexual Medicine.

  17. Analyses and comparison of a novel, hybrid, multifunctional orthopedic composite and implant

    NASA Astrophysics Data System (ADS)

    Dicicco, Michael

    In the orthopedic/medical device industry, 2, 2' -bis-(4-(2-hydroxy-3-methacryloxypropoxy)phenyl]propane (Bis-GMA)- and diurethanedimethacrylate (DUDMA)-based polymeric biomaterials have become well-known substitutes for polymethylmethacrylate (PMMA)- and ultra-high molecular weight polyethylene (UHMWPE)-based biomaterials, respectively. The development of these polymeric biomaterials cannot continue without direct comparison studies against currently marketed materials. The initiative for this research stems wholly from developing analytical methodologies that assist in qualifying novel biomaterials under development, by evaluating their chemical properties, performance, and safety. The goals of this research were: (i) Characterize the assay/quality of every resin component and quantify elution of extractable monomers from novel, DUDMA-based RHAKOSS(TM) implant, (ii) Determine degree of conversion (alpha) and rate of polymerization (Rp) for novel, Bis-GMA-based CORTOSS(TM) composite, (iii) Assess risk for radical-induced post-surgical cytotoxicity for CORTOSS, (iv) Determine if surface radical chemistries occur for sterilized RHAKOSS and assess its oxidative stability, and (v) Quantify antibiotic elution from antibiotic-impregnated CORTOSS and identify factors that control elution. The phenomena studied necessitated the utilization of several analytical spectroscopic techniques; fluorometry, differential scanning calorimetry (DSC), electron paramagnetic resonance (EPR), ultraviolet-visible (UV-VIS), attenuated total reflectance---Fourier-transform infrared (ATR-FTIR), and high performance liquid chromatography (HPLC). A battery of lateral chemical techniques were employed as well; including molecular derivatization/tagging, phase partitioning, spin-trapping, and thermal annealing. Results demonstrated that RHAKOSS monomer percent compositions were prepared according to formulations and monomer elution was virtually undetectable, serving as an empirical gauge to

  18. Orthopedic services

    MedlinePlus

    ... Dislocation Joint pain Joint swelling or inflammation Ligament tears Common orthopedic-related diagnoses based on body part ... injury Carpal tunnel syndrome Ganglion cyst Tendinitis Tendon tears ... Arthritis Bursitis Dislocation Frozen shoulder ( adhesive ...

  19. Coating with a Modular Bone Morphogenetic Peptide Promotes Healing of a Bone-Implant Gap in an Ovine Model

    PubMed Central

    Lu, Yan; Lee, Jae Sung; Nemke, Brett; Graf, Ben K.; Royalty, Kevin; Illgen, Richard; Vanderby, Ray; Markel, Mark D.; Murphy, William L.

    2012-01-01

    Despite the potential for growth factor delivery strategies to promote orthopedic implant healing, there is a need for growth factor delivery methods that are controllable and amenable to clinical translation. We have developed a modular bone growth factor, herein termed “modular bone morphogenetic peptide (mBMP)”, which was designed to efficiently bind to the surface of orthopedic implants and also stimulate new bone formation. The purpose of this study was to coat a hydroxyapatite-titanium implant with mBMP and evaluate bone healing across a bone-implant gap in the sheep femoral condyle. The mBMP molecules efficiently bound to a hydroxyapatite-titanium implant and 64% of the initially bound mBMP molecules were released in a sustained manner over 28 days. The results demonstrated that the mBMP-coated implant group had significantly more mineralized bone filling in the implant-bone gap than the control group in C-arm computed tomography (DynaCT) scanning (25% more), histological (35% more) and microradiographic images (50% more). Push-out stiffness of the mBMP group was nearly 40% greater than that of control group whereas peak force did not show a significant difference. The results of this study demonstrated that mBMP coated on a hydroxyapatite-titanium implant stimulates new bone formation and may be useful to improve implant fixation in total joint arthroplasty applications. PMID:23185610

  20. Potential Use of Porous Titanium–Niobium Alloy in Orthopedic Implants: Preparation and Experimental Study of Its Biocompatibility In Vitro

    PubMed Central

    Wang, Xu; Huang, Jia-Zhang; Zhang, Chao; Muhammad, Hassan; Ma, Xin; Liao, Qian-De

    2013-01-01

    Background The improvement of bone ingrowth into prosthesis and enhancement of the combination of the range between the bone and prosthesis are important for long-term stability of artificial joints. They are the focus of research on uncemented artificial joints. Porous materials can be of potential use to solve these problems. Objectives/Purposes This research aims to observe the characteristics of the new porous Ti-25Nb alloy and its biocompatibility in vitro, and to provide basic experimental evidence for the development of new porous prostheses or bone implants for bone tissue regeneration. Methods The Ti-25Nb alloys with different porosities were fabricated using powder metallurgy. The alloys were then evaluated based on several characteristics, such as mechanical properties, purity, pore size, and porosity. To evaluate biocompatibility, the specimens were subjected to methylthiazol tetrazolium (MTT) colorimetric assay, cell adhesion and proliferation assay using acridine staining, scanning electron microscopy, and detection of inflammation factor interleukin-6 (IL-6). Results The porous Ti-25Nb alloy with interconnected pores had a pore size of 200 µm to 500 µm, which was favorable for bone ingrowth. The compressive strength of the alloy was similar to that of cortical bone, while with the elastic modulus closer to cancellous bone. MTT assay showed that the alloy had no adverse reaction to rabbit bone marrow mesenchymal stem cells, with a toxicity level of 0 to 1. Cell adhesion and proliferation experiments showed excellent cell growth on the surface and inside the pores of the alloy. According to the IL-6 levels, the alloy did not cause any obvious inflammatory response. Conclusion All porous Ti-25Nb alloys showed good biocompatibility regardless of the percentage of porosity. The basic requirement of clinical orthopedic implants was satisfied, which made the alloy a good prospect for biomedical application. The alloy with 70% porosity had the optimum

  1. The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction

    PubMed Central

    Gibon, Emmanuel; Córdova, Luis A.; Lu, Laura; Lin, Tzu-Hua; Yao, Zhenyu; Hamadouche, Moussa; Goodman, Stuart B.

    2017-01-01

    Novel evidence-based prosthetic designs and biomaterials facilitate the performance of highly successful joint replacement (JR) procedures. To achieve this goal, constructs must be durable, biomechanically sound, and avoid adverse local tissue reactions. Different biomaterials such as metals and their alloys, polymers, ceramics, and composites are currently used for JR implants. This review focuses on (1) the biological response to the different biomaterials used for TJR and (2) the chronic inflammatory and foreign-body response induced by byproducts of these biomaterials. A homeostatic state of bone and surrounding soft tissue with current biomaterials for JR can be achieved with mechanically stable, infection free and intact (as opposed to the release of particulate or ionic byproducts) implants. Adverse local tissue reactions (an acute/chronic inflammatory reaction, periprosthetic osteolysis, loosening and subsequent mechanical failure) may evolve when the latter conditions are not met. This article (Part 2 of 2) summarizes the biological response to the non-metallic materials commonly used for joint replacement including polyethylene, ceramics, and polymethylmethacrylate (PMMA), as well as the foreign body reaction to byproducts of these materials. PMID:27080740

  2. Monitoring Bacterial Burden, Inflammation and Bone Damage Longitudinally Using Optical and μCT Imaging in an Orthopaedic Implant Infection in Mice

    PubMed Central

    Niska, Jared A.; Meganck, Jeffrey A.; Pribaz, Jonathan R.; Shahbazian, Jonathan H.; Lim, Ed; Zhang, Ning; Rice, Brad W.; Akin, Ali; Ramos, Romela Irene; Bernthal, Nicholas M.; Francis, Kevin P.; Miller, Lloyd S.

    2012-01-01

    Background Recent advances in non-invasive optical, radiographic and μCT imaging provide an opportunity to monitor biological processes longitudinally in an anatomical context. One particularly relevant application for combining these modalities is to study orthopaedic implant infections. These infections are characterized by the formation of persistent bacterial biofilms on the implanted materials, causing inflammation, periprosthetic osteolysis, osteomyelitis, and bone damage, resulting in implant loosening and failure. Methodology/Principal Findings An orthopaedic implant infection model was used in which a titanium Kirshner-wire was surgically placed in femurs of LysEGFP mice, which possess EGFP-fluorescent neutrophils, and a bioluminescent S. aureus strain (Xen29; 1×103 CFUs) was inoculated in the knee joint before closure. In vivo bioluminescent, fluorescent, X-ray and μCT imaging were performed on various postoperative days. The bacterial bioluminescent signals of the S. aureus-infected mice peaked on day 19, before decreasing to a basal level of light, which remained measurable for the entire 48 day experiment. Neutrophil EGFP-fluorescent signals of the S. aureus-infected mice were statistically greater than uninfected mice on days 2 and 5, but afterwards the signals for both groups approached background levels of detection. To visualize the three-dimensional location of the bacterial infection and neutrophil infiltration, a diffuse optical tomography reconstruction algorithm was used to co-register the bioluminescent and fluorescent signals with μCT images. To quantify the anatomical bone changes on the μCT images, the outer bone volume of the distal femurs were measured using a semi-automated contour based segmentation process. The outer bone volume increased through day 48, indicating that bone damage continued during the implant infection. Conclusions/Significance Bioluminescent and fluorescent optical imaging was combined with X-ray and

  3. Histatin 1 Enhances Cell Adhesion to Titanium in an Implant Integration Model.

    PubMed

    van Dijk, I A; Beker, A F; Jellema, W; Nazmi, K; Wu, G; Wismeijer, D; Krawczyk, P M; Bolscher, J G M; Veerman, E C I; Stap, J

    2017-04-01

    Cellular adhesion is essential for successful integration of dental implants. Rapid soft tissue integration is important to create a seal around the implant and prevent infections, which commonly cause implant failure and can result in bone loss. In addition, soft tissue management is important to obtain good dental aesthetics. We previously demonstrated that the salivary peptide histatin 1 (Hst1) causes a more than 2-fold increase in the ability of human adherent cells to attach and spread on a glass surface. Cells treated with Hst1 attached more rapidly and firmly to the substrate and to each other. In the current study, we examine the potential application of Hst1 for promotion of dental implant integration. Our results show that Hst1 enhances the attachment and spreading of soft tissue cell types (oral epithelial cells and fibroblasts) to titanium (Ti) and hydroxyapatite (HAP), biomaterials that have found wide applications as implant material in dentistry and orthopedics. For improved visualization of cell adhesion to Ti, we developed a novel technique that uses sputtering to deposit a thin, transparent layer of Ti onto glass slides. This approach allows detailed, high-resolution analysis of cell adherence to Ti in real time. Furthermore, our results suggest that Hst1 has no negative effects on cell survival. Given its natural occurrence in the oral cavity, Hst1 could be an attractive agent for clinical application. Importantly, even though Hst1 is specific for saliva of humans and higher primates, it stimulated the attachment and spreading of canine cells, paving the way for preclinical studies in canine models.

  4. Biodegradation and cytotoxicity of ciprofloxacin-loaded hydroxyapatite-polycaprolactone nanocomposite film for sustainable bone implants.

    PubMed

    Nithya, Rajendran; Meenakshi Sundaram, Nachiappan

    2015-01-01

    In recent years there has been a steep increase in the number of orthopedic patients for many reasons. One major reason is osteomyelitis, caused by pyrogenic bacteria, with progressive infection of the bone or bone marrow and surrounding tissues. So antibiotics must be introduced during bone implantation to avoid prolonged infection. The objective of the study reported here was to prepare a composite film of nanocrystalline hydroxyapatite (HAp) and polycaprolactone (PCL) polymer loaded with ciprofloxacin, a frequently used antibiotic agent for bone infections. Nanocrystalline HAp was synthesized by precipitation method using the precursor obtained from eggshell. The nanocomposite film (HAp-PCL-ciprofloxacin) was prepared by solvent evaporation. Drug-release and biodegradation studies were undertaken by immersing the composite film in phosphate-buffered saline solution, while a cytotoxicity test was performed using the fibroblast cell line NIH-3T3 and osteoblast cell line MG-63. The pure PCL film had quite a low dissolution rate after an initial sharp weight loss, whereas the ciprofloxacin-loaded HAp-PCL nanocomposite film had a large weight loss due to its fast drug release. The composite film had higher water absorption than the pure PCL, and increasing the concentration of the HAp increased the water absorption. The in vitro cell-line study showed a good biocompatibility and bioactivity of the developed nanocomposite film. The prepared film will act as a sustainable bone implant in addition to controlled drug delivery.

  5. Prosthetic joint infection development of an evidence-based diagnostic algorithm.

    PubMed

    Mühlhofer, Heinrich M L; Pohlig, Florian; Kanz, Karl-Georg; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; Kelch, Sarah; Harrasser, Norbert; von Eisenhart-Rothe, Rüdiger; Schauwecker, Johannes

    2017-03-09

    Increasing rates of prosthetic joint infection (PJI) have presented challenges for general practitioners, orthopedic surgeons and the health care system in the recent years. The diagnosis of PJI is complex; multiple diagnostic tools are used in the attempt to correctly diagnose PJI. Evidence-based algorithms can help to identify PJI using standardized diagnostic steps. We reviewed relevant publications between 1990 and 2015 using a systematic literature search in MEDLINE and PUBMED. The selected search results were then classified into levels of evidence. The keywords were prosthetic joint infection, biofilm, diagnosis, sonication, antibiotic treatment, implant-associated infection, Staph. aureus, rifampicin, implant retention, pcr, maldi-tof, serology, synovial fluid, c-reactive protein level, total hip arthroplasty (THA), total knee arthroplasty (TKA) and combinations of these terms. From an initial 768 publications, 156 publications were stringently reviewed. Publications with class I-III recommendations (EAST) were considered. We developed an algorithm for the diagnostic approach to display the complex diagnosis of PJI in a clear and logically structured process according to ISO 5807. The evidence-based standardized algorithm combines modern clinical requirements and evidence-based treatment principles. The algorithm provides a detailed transparent standard operating procedure (SOP) for diagnosing PJI. Thus, consistently high, examiner-independent process quality is assured to meet the demands of modern quality management in PJI diagnosis.

  6. A novel hydroxyapatite film coated with ionic silver via inositol hexaphosphate chelation prevents implant-associated infection

    NASA Astrophysics Data System (ADS)

    Funao, Haruki; Nagai, Shigenori; Sasaki, Aya; Hoshikawa, Tomoyuki; Tsuji, Takashi; Okada, Yasunori; Koyasu, Shigeo; Toyama, Yoshiaki; Nakamura, Masaya; Aizawa, Mamoru; Matsumoto, Morio; Ishii, Ken

    2016-03-01

    Various silver-coated implants have been developed to prevent implant-associated infections, and have shown dramatic effects in vitro. However, the in vivo results have been inconsistent. Recent in vitro studies showed that silver exerts antibacterial activity by mediating the generation of reactive oxygen species in the presence of oxygen. To maintain its antibacterial activity in vivo, the silver should remain in an ionic state and be stably bound to the implant surface. Here, we developed a novel bacteria-resistant hydroxyapatite film in which ionic silver is immobilized via inositol hexaphosphate chelation using a low-heat immersion process. This bacteria-resistant coating demonstrated significant antibacterial activity both in vitro and in vivo. In a murine bioluminescent osteomyelitis model, no bacteria were detectable 21 days after inoculation with S. aureus and placement of this implant. Serum interleukin-6 was elevated in the acute phase in this model, but it was significantly lower in the ionic-silver group than the control group on day 2. Serum C-reactive protein remained significantly higher in the control group than the ionic-silver group on day 14. Because this coating is produced by a low-heat immersion process, it can be applied to complex structures of various materials, to provide significant protection against implant-associated infections.

  7. Regenerative Surgical Treatment of Peri-implantitis

    ClinicalTrials.gov

    2016-08-31

    Failure of Dental Implant Due to Infection; Infection; Inflammation; Peri-implantitis; Bacterial Infections; Bleeding of Subgingival Space; Molecular Sequence Variation; Periodontal Diseases; Mouth Diseases

  8. Cadaveric aorta implantation for aortic graft infection.

    PubMed

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  9. Innovation and Entrepreneurship: Perspectives From Orthopedic Surgery.

    PubMed

    Campbell, Kevin J; Louie, Philip K; Khorsand, Derek A; Frisch, Nicholas B; Gerlinger, Tad L; Levine, Brett R

    2018-05-01

    Orthopedic surgeons are tasked with treating complex patients while employing critical surgical skills, clinical knowledge, and new technologies. The constant inundation of information, coupled with hours in the hospital setting, provides unique perspectives on various aspects of how health care is delivered, thereby creating a milieu ripe for innovation. The rigors of an orthopedic career make it challenging for physicians to translate an idea into a great product. Through the authors' experiences at a tertiary orthopedic practice, they review the process of taking an idea from concept to fruition. [Orthopedics. 2018; 41(3):135-140.]. Copyright 2018, SLACK Incorporated.

  10. Teicoplanin-loaded borate bioactive glass implants for treating chronic bone infection in a rabbit tibia osteomyelitis model.

    PubMed

    Zhang, Xin; Jia, Weitao; Gu, Yifei; Xiao, Wei; Liu, Xin; Wang, Deping; Zhang, Changqing; Huang, Wenhai; Rahaman, Mohamed N; Day, Delbert E; Zhou, Nai

    2010-08-01

    The treatment of chronic osteomyelitis (bone infection) remains a clinical challenge. In this work, pellets composed of a chitosan-bonded mixture of borate bioactive glass particles (<50microm) and teicoplanin powder (antibiotic), were evaluated in vitro and in vivo for treating chronic osteomyelitis induced by methicillin-resistant Staphylococcus aureus (MRSA) in a rabbit model. When immersed in phosphate-buffered saline, the pellets showed sustained release of teicoplanin over 20-30 days, while the bioactive glass converted to hydroxyapatite (HA) within 7 days, eventually forming a porous HA structure. Implantation of the teicoplanin-loaded pellets in a rabbit tibia osteomyelitis model resulted in the detection of teicoplanin in the blood for about 9 days. The implants converted to a bone-like HA graft, and supported the ingrowth of new bone into the tibia defects within 12 weeks of implantation. Microbiological, histological and scanning electron microscopy techniques showed that the implants provided a cure for the bone infection. The results indicate that the teicoplanin-loaded borate bioactive glass implant, combining sustained drug release with the ability to support new bone ingrowth, could provide a method for treating chronic osteomyelitis. Copyright 2010 Elsevier Ltd. All rights reserved.

  11. Cardiac Implantable Electronic Device-Related Infection and Extraction Trends in the U.S.

    PubMed

    Sridhar, Arun Raghav Mahankali; Lavu, Madhav; Yarlagadda, Vivek; Reddy, Madhu; Gunda, Sampath; Afzal, Rizwan; Atkins, Donita; Gopinathanair, Rakesh; Dawn, Buddhadeb; Lakkireddy, Dhanunjaya R

    2017-03-01

    Implantation of cardiac implanted electronic device (CIED) has surged lately. This resulted in a rise in cardiac device-related infections (CDI) and inevitably, lead extractions. We examined the recent national trend in the incidence of CIED infections and lead extractions in hospitalized patients and associated mortality. Using the Nationwide Inpatient Sample for the years 2003-2011 we identified patients diagnosed with a CDI-associated infection as determined by discharge ICD-9 diagnostic codes. We examined the trend of device-related infections overall and in different subgroups. We studied mortality associated with device infections, lead extractions, associated costs, and length of stay. There is a significant increase in the number of hospitalizations due to CDI from 5,308 in the year 2003 to 9,948 in 2011. Males (68%), Caucasians (77%), and age group 65-84 years (56.4%) accounted for majority of CDI. The mortality associated with CDI was 4.5 %, and was worse in higher age groups (2.5% in 18-44 years compared to 5.3% in 85+ years, P < 0.001). Average length of stay was unchanged over the years remaining at 13.6 days; however, mean hospitalization charges increased from $91,348 in 2003 to $173,211 in 2011 (P < 0.001). Among all lead extraction procedures, the percentage of patients undergoing lead extraction secondary to CDI also increased from 2003 (59.1%) to 2011 (76.7%), P-value < 0.001. Healthcare burden associated with CDI infections and associated lead extractions has significantly increased in the recent years. Despite an increase in cost associated with CIED infections, mortality remains the same, and is higher in older patients. © 2017 Wiley Periodicals, Inc.

  12. Zirconium, calcium, and strontium contents in magnesium based biodegradable alloys modulate the efficiency of implant-induced osseointegration

    PubMed Central

    Mushahary, Dolly; Sravanthi, Ragamouni; Li, Yuncang; Kumar, Mahesh J; Harishankar, Nemani; Hodgson, Peter D; Wen, Cuie; Pande, Gopal

    2013-01-01

    Development of new biodegradable implants and devices is necessary to meet the increasing needs of regenerative orthopedic procedures. An important consideration while formulating new implant materials is that they should physicochemically and biologically mimic bone-like properties. In earlier studies, we have developed and characterized magnesium based biodegradable alloys, in particular magnesium-zirconium (Mg-Zr) alloys. Here we have reported the biological properties of four Mg-Zr alloys containing different quantities of strontium or calcium. The alloys were implanted in small cavities made in femur bones of New Zealand White rabbits, and the quantitative and qualitative assessments of newly induced bone tissue were carried out. A total of 30 experimental animals, three for each implant type, were studied, and bone induction was assessed by histological, immunohistochemical and radiological methods; cavities in the femurs with no implants and observed for the same period of time were kept as controls. Our results showed that Mg-Zr alloys containing appropriate quantities of strontium were more efficient in inducing good quality mineralized bone than other alloys. Our results have been discussed in the context of physicochemical and biological properties of the alloys, and they could be very useful in determining the nature of future generations of biodegradable orthopedic implants. PMID:23976848

  13. Comparison of a low-pressure and a high-pressure pulsatile lavage during débridement for orthopaedic implant infection.

    PubMed

    Muñoz-Mahamud, E; García, S; Bori, G; Martínez-Pastor, J C; Zumbado, J A; Riba, J; Mensa, J; Soriano, A

    2011-09-01

    The aim of our study was to compare the effectiveness of high-pressure pulsatile lavage and low-pressure lavage in patients with an orthopaedic implant infection treated with open débridement followed by antibiotic treatment. Patients with an orthopaedic implant infection requiring open débridement from January 2008 to August 2009 were randomized prospectively to a low-pressure or a high-pressure pulsatile lavage arm. Relevant information about demographics, co-morbidity, type of implant, microbiology data, surgical treatment, and outcome were recorded. Comparison of proportions was made using χ(2) test or Fisher exact test when necessary. The Kaplan-Meier survival method was used to estimate the cumulative probability of treatment failure from open débridement to the last visit. Seventy-nine patients were included. There were no differences between the main characteristics between both groups (p > 0.05). Mean (SD) age of the whole cohort was 70.2 (11.9) years. There were 46 infections on knee prosthesis, 17 on hip prosthesis, 7 on hip hemiarthroplasties and 9 on osteosynthesis devices. There were 69 acute post-surgical infections, 8 acute haematogenous infections and 2 chronic infections. The most common microorganisms isolated were coagulase-negative Staphylococci in 34 cases, Staphylococcus aureus in 26 and Escherichia coli in 19 cases. There were 30 polymicrobial infections. A total of 42 and 37 patients were randomized to a high-pressure pulsatile or a low-pressure lavage, respectively. There was no difference in the success rate between both arms (80.9 vs. 86.5%, p = 0.56). The use of a high-pressure pulsatile lavage during open débridement of implant infections had a similar success rate as a low-pressure lavage.

  14. [Carbon fiber-reinforced plastics as implant materials].

    PubMed

    Bader, R; Steinhauser, E; Rechl, H; Siebels, W; Mittelmeier, W; Gradinger, R

    2003-01-01

    Carbon fiber-reinforced plastics have been used clinically as an implant material for different applications for over 20 years.A review of technical basics of the composite materials (carbon fibers and matrix systems), fields of application,advantages (e.g., postoperative visualization without distortion in computed and magnetic resonance tomography), and disadvantages with use as an implant material is given. The question of the biocompatibility of carbon fiber-reinforced plastics is discussed on the basis of experimental and clinical studies. Selected implant systems made of carbon composite materials for treatments in orthopedic surgery such as joint replacement, tumor surgery, and spinal operations are presented and assessed. Present applications for carbon fiber reinforced plastics are seen in the field of spinal surgery, both as cages for interbody fusion and vertebral body replacement.

  15. Surgical site infections following transcatheter apical aortic valve implantation: incidence and management.

    PubMed

    Baillot, Richard; Fréchette, Éric; Cloutier, Daniel; Rodès-Cabau, Josep; Doyle, Daniel; Charbonneau, Éric; Mohammadi, Siamak; Dumont, Éric

    2012-11-13

    The present study was undertaken to examine the incidence and management of surgical site infection (SSI) in patients submitted to transapical transcatheter aortic valve implantation (TA-TAVI). From April 2007 to December 2011, 154 patients underwent TA-TAVI with an Edwards Sapien bioprosthesis (ES) at the Institut Universitaire de Cardiologie et Pneumologie de Québec (IUCPQ) as part of a multidisciplinary program to prospectively evaluate percutaneous aortic valve implantation. Patient demographics, perioperative variables, and postoperative complications were recorded in a prospective registry. Five (3.2%) patients in the cohort presented with an SSI during the study period. The infections were all hospital-acquired (HAI) and were considered as organ/space SSI's based on Center for Disease Control criteria (CDC). Within the first few weeks of the initial procedure, these patients presented with an abscess or chronic draining sinus in the left thoracotomy incision and were re-operated. The infection spread to the apex of the left ventricle in all cases where pledgeted mattress sutures could be seen during debridement. Patients received multiple antibiotic regimens without success until the wound was surgically debrided and covered with viable tissue. The greater omentum was used in three patients and the pectoralis major muscle in the other two. None of the patients died or had a recurrent infection. Three of the patients were infected with Staphylococcus epidermidis, one with Staphylococcus aureus, and one with Enterobacter cloacae. Patients with surgical site infections were significantly more obese with higher BMI (31.4±3.1 vs 26.2±4.4 p=0.0099) than the other patients in the cohort. While TA-TAVI is a minimally invasive technique, SSIs, which are associated with obesity, remain a concern. Debridement and rib resection followed by wound coverage with the greater omentum and/or the pectoralis major muscle were used successfully in these patients.

  16. Dose-Dependent Effects of CeO2 on Microstructure and Antibacterial Property of Plasma-Sprayed TiO2 Coatings for Orthopedic Application

    NASA Astrophysics Data System (ADS)

    Zhao, Xiaobing; Liu, Gaopeng; Zheng, Hai; Cao, Huiliang; Liu, Xuanyong

    2015-02-01

    Titanium and its alloys have been used extensively for orthopedic and dental implants. Although these devices have achieved high rates of success, two major complications may be encountered: the lack of osseointegration and the biomaterial-related infection. Accordingly, cerium oxide (CeO2)-doped titanium oxide (TiO2) materials were coated on titanium by an atmospheric plasma spraying (APS) technique. The phase structures, morphologies, and surface chemical states of the obtained coatings were characterized by x-ray diffraction, scanning electron microscopy, and x-ray photoelectron spectroscopy techniques. The in vitro antibacterial and cytocompatibility of the materials were studied with Staphylococcus aureus ( S. aureus, ATCC25923) and osteoblast precursor cell line MC3T3-E1. The results indicated that the addition of CeO2 shifts slightly the diffraction peaks of TiO2 matrix to low angles but does not change its rutile phase structure. In addition, the CeO2/TiO2 composite coatings possess dose-dependent corrosion resistance and antimicrobial properties. And doping of 10 wt.% CeO2 exhibits the highest activity against S. aureus, improved corrosion resistance, and competitive cytocompatibility, which argues a promising option for balancing the osteogenetic and antibacterial properties of titanium implants.

  17. Moral Dilemmas in Pediatric Orthopedics.

    PubMed

    Mercuri, John J; Vigdorchik, Jonathan M; Otsuka, Norman Y

    2015-12-01

    All orthopedic surgeons face moral dilemmas on a regular basis; however, little has been written about the moral dilemmas that are encountered when providing orthopedic care to pediatric patients and their families. This article aims to provide surgeons with a better understanding of how bioethics and professionalism apply to the care of their pediatric patients. First, several foundational concepts of both bioethics and professionalism are summarized, and definitions are offered for 16 important terms within the disciplines. Next, some of the unique aspects of pediatric orthopedics as a subspecialty are reviewed before engaging in a discussion of 5 common moral dilemmas within the field. Those dilemmas include the following: (1) obtaining informed consent and assent for either surgery or research from pediatric patients and their families; (2) performing cosmetic surgery on pediatric patients; (3) caring for pediatric patients with cognitive or physical impairments; (4) caring for injured pediatric athletes; and (5) meeting the demand for pediatric orthopedic care in the United States. Pertinent considerations are reviewed for each of these 5 moral dilemmas, thereby better preparing surgeons for principled moral decision making in their own practices. Each of these dilemmas is inherently complex with few straightforward answers; however, orthopedic surgeons have an obligation to take the lead and better define these kinds of difficult issues within their field. The lives of pediatric patients and their families will be immeasurably improved as a result. Copyright 2015, SLACK Incorporated.

  18. Case-control study of surgical site infections associated with pacemakers and implantable cardioverter-defibrillators.

    PubMed

    Marschall, Jonas; Hopkins-Broyles, Diane; Jones, Marilyn; Fraser, Victoria J; Warren, David K

    2007-11-01

    In 2000, the rate of surgical site infections (SSIs) associated with pacemaker and implantable cardioverter-defibrillator (ICD) procedures performed in the cardiothoracic operating rooms of hospital A was 16% (19 of 116 procedures resulted in infections). This study investigates risks for SSI associated with these procedures in the cardiothoracic operating room. Unmatched 1 : 3 case-control study performed over a 12-month period among patients who had undergone implantation of a pacemaker and/or ICD. A standardized observation scrutinized infection control practices in the area where the procedures were performed. The cardiothoracic operating rooms of hospital A, which belongs to a hospital consortium in the midwestern United States. Patients with SSI were identified as case patients. Control patients were chosen from the group of uninfected patients who had procedures performed during the same period as case patients. A total of 19 SSIs associated with pacemaker and ICD procedures were retrospectively identified among the patients who underwent procedures in these cardiothoracic operating rooms. Culture samples were obtained from 7 patients; 2 yielded coagulase-negative Staphylococcus on culture, 2 yielded Staphylococcus aureus, 1 yielded Serratia marcescens, and 2 showed no growth. In the case-control study, age, race, sex, diabetes mellitus, smoking history, timing of antibiotic therapy, and hair removal did not differ significantly between case patients and control patients. Case patients were more likely to have an abdominal device in place (odds ratio [OR], 5.5 [95% confidence interval {CI}, 1.6-19.3]; P=.006) and less likely to have received a new implant (OR 0.3 [95% CI, 0.1-0.8]; P=.02) or to have had new leads placed (OR, 0.2 [95% CI, 0.1-0.6]; P=.003). Abdominal placement of implanted devices was associated with occurrence of an SSI after pacemaker and/or ICD procedures.

  19. Investigating the structure and biocompatibility of niobium and titanium oxides as coatings for orthopedic metallic implants.

    PubMed

    Pradhan, D; Wren, A W; Misture, S T; Mellott, N P

    2016-01-01

    Applying sol gel based coatings to orthopedic metallic implant materials can significantly improve their properties and lifespan in vivo. For this work, niobium (Nb2O5) and titanium (TiO2) oxides were prepared via solution processing in order to determine the effect of atomic arrangement (amorphous/crystalline) on bioactivity. Thermal evaluation on the synthesized materials identified an endotherm for Nb2O5 at 75 °C with 40% weight loss below 400 °C, and minimal weight loss between 400 and 850 °C. Regarding TiO2 an endotherm was present at 92 °C with 25% weight loss below 400 °C, and 4% between 400 and 850 °C. Phase evolution was determined using High Temperature X-ray Diffraction (HT-XRD) where amorphous-Nb2O5 (450 °C), hexagonal-Nb2O5 (525 °C), orthorhombic-Nb2O5 (650 °C), amorphous-TiO2 (275 °C) and tetragonal TiO2 (500 °C) structures were produced. Simulated body fluid (SBF) testing was conducted over 1, 7 and 30 days and resulted in positive chemical and morphological changes for crystalline Nb2O5 (525 °C) and TiO2 (500 °C) after 30 days of incubation. Rod-like CaP deposits were observed on the surfaces using Scanning Electron Microscopy (FE-SEM) and Grazing Incidence-X-ray Diffraction (GI-XRD) shows that the deposits were X-ray amorphous. Cell viability was higher with the TiO2 (122%) samples when compared to the growing cell population while Nb2O5 samples exhibited a range of viability (64-105%), partially dependent on materials atomic structure. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Orthopedic evaluation

    NASA Technical Reports Server (NTRS)

    Walden, T.

    1978-01-01

    The clinical performance of the Lixiscope in orthopedics was compared with routine radiography. Portability and size were the major advantages of the Lixiscope. The main disadvantage at this point in time was the Lixiscope's inability to study large areas.

  1. Delay to orthopedic consultation for isolated limb injury

    PubMed Central

    Rouleau, Dominique M.; Feldman, Debbie Ehrmann; Parent, Stefan

    2009-01-01

    ABSTRACT OBJECTIVE To describe referral mechanisms for referral to orthopedic surgery for isolated limb injuries in a public health care system and to identify factors affecting access. DESIGN Cross-sectional survey. SETTING Orthopedic surgery service in a level 1 trauma centre in Montreal, Que. PARTICIPANTS We conducted a prospective study of 166 consecutive adults (mean age 48 years) referred to orthopedic surgery for isolated limb injuries during a 4-month period. MAIN OUTCOME MEASURES Self-reported data on the nature of the trauma, the elapsed time between injury and orthopedic consultation, the number and type of previous primary care consultations, sociodemographic characteristics, and the level of satisfaction with care. RESULTS Average time between the injury and orthopedic consultation was 89 hours (range 3 to 642), with an average of 68 hours (range 0 to 642) for delay between primary care consultation and orthopedic consultation. A total of 36% of patients with time-sensitive diagnoses had unacceptable delays to orthopedic consultation according to the Quebec Orthopaedic Association guidelines. Lower limb injury, consulting first at another hospital, living far from the trauma centre, patient perception of low severity, and having a soft tissue injury were associated with longer delays. CONCLUSION Identifying gaps and risk factors for slower access might help improve referral mechanisms for orthopedic consultation. PMID:19826162

  2. Tourniquet use in orthopedic surgery: a descriptive survey study among Turkish orthopedic surgeons and residents in Istanbul.

    PubMed

    Yalçınkaya, Merter; Sökücü, Sami; Erdoğan, Sinan; Kabukçuoğlu, Yavuz S

    2014-01-01

    The aim of this study was to investigate and interpret the trends in tourniquet use and the accuracy of knowledge among Turkish orthopedic physicians through face-to-face survey. Turkish orthopedic physicians actively practicing operative orthopedics were questioned in a 12 question face-to-face survey. Personal information of physicians, preferred cuff pressure (CP) and tourniquet inflation time (TIT) and the source of the information for these preferences were questioned. Answers gathered were analyzed statistically. The survey was completed by 211 orthopedic physicians. Mean preferred CP and TIT was 247.1 mmHg and 108.6 minutes, respectively, in the upper limb (UL) and 345.02 mmHg and 122.4 minutes, respectively, in the lower limb (LL). A statistically significant correlation was found between the amount of pressure preferred in the LL and the years of practice; longer the years in practice, higher the amount of pressure preferred (r=0.144, p=0.04). Tourniquets were used for a maximum period of 120 minutes for the UL by 95.7% of participants and for the LL by 84.8%. The amount of CP used by the orthopedic physicians surveyed is inconsistent with the literature with frequent use of CP higher than those scientifically recommended. The outcomes of the survey should be cautionary for orthopedic physicians to review the current utilization and replace personal teachings and experience-based methods with evidence-based best practices for tourniquet application.

  3. Microbiology and Biofilm Trends of Silicone Lacrimal Implants: Comparing Infected Versus Routinely Removed Stents.

    PubMed

    Samimi, David B; Ediriwickrema, Lilangi S; Bielory, Brett P; Miller, Darlene; Lee, Wendy; Johnson, Thomas E

    To investigate the pathogens and biofilms responsible for clinically significant infection of silicone stents implanted within the lacrimal system. Retrospective review of culture results and patient demographics for all silicone lacrimal stents removed early for clinically significant infection and sent to the Bascom Palmer Microbiology Laboratory through the end of year 2010. As a control, routinely removed, clinically noninfected stents from the same institution were prospectively sent for culture over a 6-month period. Four clinically infected and 6 clinically noninfected stents showing mucus within the lumen at removal were sent for scanning electron microscopy. Images were randomized and graded by a microbiologist for the presence of organisms, matrix deposits, organisms within matrix, and overall impression of significant biofilm formation. Nineteen stents were included in the study; 100% of clinically infected (n = 10) and noninfected (n = 9) stents were culture positive. Culture positivity for nontuberculous mycobacterium was found in 90% of infected stents and none of the noninfected stents (p < 0.001). Of infected stents, 50% grew Gram-positive organisms compared with 89% of noninfected stents (p = 0.07). Fifty percent of infected versus 67% of noninfected stents were culture positive for Gram-negative organisms (p = 0.46). Electron microscopy of stents revealed organisms consistent with culture results (size, shape) in planktonic and biofilm form. Masked observer image grading revealed a statistically significant higher amount of organism and biofilm on infected versus noninfected specimen. Nontuberculous mycobacteria comprise the primary pathogens responsible for clinically significant infection of silicone stents in the lacrimal system in South Florida. Robust biofilm production by this organism likely plays a role in pathogenesis. Further research into biofilm-related lacrimal implant infection may aid in the development of useful prevention and

  4. Breast Implant-Associated Infections: The Role of the National Surgical Quality Improvement Program and the Local Microbiome.

    PubMed

    Cohen, Justin B; Carroll, Cathy; Tenenbaum, Marissa M; Myckatyn, Terence M

    2015-11-01

    The most common cause of surgical readmission after breast implant surgery remains infection. Six causative organisms are principally involved: Staphylococcus epidermidis and S. aureus, Escherichia, Pseudomonas, Propionibacterium, and Corynebacterium. The authors investigated the infection patterns and antibiotic sensitivities to characterize their local microbiome and determine ideal antibiotic selection. A retrospective review of 2285 consecutive implant-based breast procedures was performed. Included surgical procedures were immediate and delayed breast reconstruction, tissue expander exchange, and cosmetic augmentation. Patient demographics, chemotherapy and/or irradiation status, implant characteristics, explantation reason, time to infection, microbiological data, and antibiotic sensitivities were reviewed. Forty-seven patients (2.1 percent) required inpatient admission for antibiotics, operative explantation, or drainage by interventional radiology. The infection rate varied depending on surgical procedure, with the highest rate seen in mastectomy and immediate tissue expander reconstruction (6.1 percent). The mean time to explantation was 41 days. Only 50 percent of infections occurred within 30 days of the indexed National Surgical Quality Improvement Program operation. The most commonly isolated organisms were coagulase-negative Staphylococcus (27 percent), methicillin-sensitive S. aureus (25 percent), methicillin-resistant S. aureus (7 percent), Pseudomonas (7 percent), and Peptostreptococcus (7 percent). All Gram-positive organisms were sensitive to vancomycin, linezolid, tetracycline, and doxycycline; all Gram-negative organisms were sensitive to gentamicin and cefepime. Empiric antibiotics should be vancomycin (with the possible inclusion of gentamicin) based on their broad effectiveness against the authors' unique microbiome. Minor infections should be treated with tetracycline or doxycycline as a second-line agent. National Surgical Quality

  5. Photodynamic inactivation of biofilm: taking a lightly colored approach to stubborn infection

    PubMed Central

    de Melo, Wanessa CMA; Avci, Pinar; de Oliveira, Milene Nóbrega; Gupta, Asheesh; Vecchio, Daniela; Sadasivam, Magesh; Chandran, Rakkiyappan; Huang, Ying-Ying; Yin, Rui; Perussi, Livia R; Tegos, George P; Perussi, Janice R; Dai, Tianhong; Hamblin, Michael R

    2015-01-01

    Microbial biofilms are responsible for a variety of microbial infections in different parts of the body, such as urinary tract infections, catheter infections, middle-ear infections, gingivitis, caries, periodontitis, orthopedic implants, and so on. The microbial biofilm cells have properties and gene expression patterns distinct from planktonic cells, including phenotypic variations in enzymic activity, cell wall composition and surface structure, which increase the resistance to antibiotics and other antimicrobial treatments. There is consequently an urgent need for new approaches to attack biofilm-associated microorganisms, and antimicrobial photodynamic therapy (aPDT) may be a promising candidate. aPDT involves the combination of a nontoxic dye and low-intensity visible light which, in the presence of oxygen, produces cytotoxic reactive oxygen species. It has been demonstrated that many biofilms are susceptible to aPDT, particularly in dental disease. This review will focus on aspects of aPDT that are designed to increase efficiency against biofilms modalities to enhance penetration of photosensitizer into biofilm, and a combination of aPDT with biofilm-disrupting agents. PMID:23879608

  6. The oral cavity is not a primary source for implantable pacemaker or cardioverter defibrillator infections

    PubMed Central

    2013-01-01

    Background To test the hypothesis that the oral cavity is a potential source for implantable pacemaker and cardioverter defibrillators infections, the bacterial diversity on explanted rhythm heart management devices was investigated and compared to the oral microbiome. Methods A metagenomic approach was used to analyze the bacterial diversity on the surfaces of non-infected and infected pacemakers. The DNA from surfaces swaps of 24 non-infected and 23 infected pacemaker were isolated and subjected to bacterial-specific DNA amplification, single strand conformation polymorphism- (SSCP) and sequencing analysis. Species-specific primer sets were used to analyze for any correlation between bacterial diversity on pacemakers and in the oral cavity. Results DNA of bacterial origin was detected in 21 cases on infected pacemakers and assigned to the bacterial phylotypes Staphylococcus epidermidis, Propionibacterium acnes, Staphylococcus aureus, Staphylococcus schleiferi and Stapyhlococcus. In 17 cases bacterial DNA was found on pacemakers with no clinical signs of infections. On the basis of the obtained sequence data, the phylotypes Propionibacterium acnes, Staphylococcus and an uncultured bacterium were identified. Propionibacterium acnes and Staphylococcus epidermidis were the only bacteria detected in pacemeaker (n = 25) and oral samples (n = 11). Conclusions The frequency of the coincidental detection of bacteria on infected devices and in the oral cavity is low and the detected bacteria are highly abundant colonizers of non-oral human niches. The transmission of oral bacteria to the lead or device of implantable pacemaker or cardioverter defibrillators is unlikely relevant for the pathogenesis of pacemaker or cardioverter defibrillators infections. PMID:23575037

  7. Modular adaptive implant based on smart materials.

    PubMed

    Bîzdoacă, N; Tarniţă, Daniela; Tarniţă, D N

    2008-01-01

    Applications of biological methods and systems found in nature to the study and design of engineering systems and modern technology are defined as Bionics. The present paper describes a bionics application of shape memory alloy in construction of orthopedic implant. The main idea of this paper is related to design modular adaptive implants for fractured bones. In order to target the efficiency of medical treatment, the implant has to protect the fractured bone, for the healing period, undertaking much as is possible from the daily usual load of the healthy bones. After a particular stage of healing period is passed, using implant modularity, the load is gradually transferred to bone, assuring in this manner a gradually recover of bone function. The adaptability of this design is related to medical possibility of the physician to made the implant to correspond to patient specifically anatomy. Using a CT realistic numerical bone models, the mechanical simulation of different types of loading of the fractured bones treated with conventional method are presented. The results are commented and conclusions are formulated.

  8. Progress and outlook of inorganic nanoparticles for delivery of nucleic acid sequences related to orthopedic pathologies: a review.

    PubMed

    Wagner, Darcy E; Bhaduri, Sarit B

    2012-02-01

    The anticipated growth in the aging population will drastically increase medical needs of society; of which, one of the largest components will undoubtedly be from orthopedic-related pathologies. There are several proposed solutions being investigated to cost-effectively prepare for the future--pharmaceuticals, implant devices, cell and gene therapies, or some combination thereof. Gene therapy is one of the more promising possibilities because it seeks to correct the root of the problem, thereby minimizing treatment duration and cost. Currently, viral vectors have shown the highest efficacies, but immunological concerns remain. Nonviral methods show reduced immune responses but are regarded as less efficient. The nonviral paradigms consist of mechanical and chemical approaches. While organic-based materials have been used more frequently in particle-based methods, inorganic materials capable of delivery have distinct advantages, especially advantageous in orthopedic applications. The inorganic gene therapy field is highly interdisciplinary in nature, and requires assimilation of knowledge across the broad fields of cell biology, biochemistry, molecular genetics, materials science, and clinical medicine. This review provides an overview of the role each area plays in orthopedic gene therapy as well as possible future directions for the field.

  9. Prevention of percutaneous driveline infection after left ventricular assist device implantation: prophylactic antibiotics are not necessary.

    PubMed

    Stulak, John M; Maltais, Simon; Cowger, Jennifer; Joyce, Lyle D; Daly, Richard C; Park, Soon J; Aaronson, Keith D; Pagani, Francis D

    2013-01-01

    Infection is a major source of morbidity and mortality after ventricular assist device (VAD) implantation. The percutaneous driveline is the most common site of infection in these patients and often serves as a portal to deeper pump infections. There are no data defining the role of prophylactic antibiotics in preventing these infections. We compared all patients who underwent primary HeartMate II VAD implantation at two different institutions employing two different driveline infection prevention strategies between February 2007 and September 2011. While all patients received perioperative antibiotics, driveline maintenance strategies included sterile dressing changes with Hibiclens application without continued prophylactic antibiotics (Abx) (Mayo Clinic, n = 141, No Abx) and sterile dressing changes with continued prophylactic antibiotics (University of Michigan Hospital, n = 144, Abx). Although gender was similar between cohorts (Abx: 79% male vs. No Abx: 84% male, p = 0.25), median age at implant (Abx: 59 vs. No Abx: 64, p = 0.001) and destination therapy as indication for VAD (Abx: 22% vs. No Abx: 60%, p < 0.001) were significantly different. Follow-up was available in all late survivors (Abx: 140 patients, No Abx: 127 patients). Median duration of support was similar between groups (Abx: 12.3 months vs. No Abx: 11 months, p = 0.44). Total patient-years of device support were 172 years for 140 patients in the Abx cohort and 146 years for 127 patients in the No Abx cohort. Driveline drainage/infection was observed in 25 of 140 patients (18%) in the Abx group and 16 of 127 (13%) in the No Abx group (p = 0.15). Device exchange for major driveline infection was performed in seven patients in the Abx group and 0 patients in the No Abx group. Total driveline infection events per patient-years of support were 0.15 for the Abx group and 0.11 in the No Abx group (p = 0.43). There was no significant difference in the raw incidence of major driveline infections or

  10. Ion beam sputter modification of the surface morphology of biological implants

    NASA Technical Reports Server (NTRS)

    Weigand, A. J.; Banks, B. A.

    1976-01-01

    The surface chemistry and texture of materials used for biological implants may significantly influence their performance and biocompatibility. Recent interest in the microscopic control of implant surface texture has led to the evaluation of ion beam sputtering as a potentially useful surface roughening technique. Ion sources, similar to electron bombardment ion thrusters designed for propulsive applications, are used to roughen the surfaces of various biocompatible alloys or polymer materials. These materials are typically used for dental implants, orthopedic prostheses, vascular prostheses, and artificial heart components. Masking techniques and resulting surface textures are described along with progress concerning evaluation of the biological response to the ion beam sputtered surfaces.

  11. Ion-beam-sputter modification of the surface morphology of biological implants

    NASA Technical Reports Server (NTRS)

    Weigand, A. J.; Banks, B. A.

    1977-01-01

    The surface chemistry and texture of materials used for biological implants may significantly influence their performance and biocompatibility. Recent interest in the microscopic control of implant surface texture has led to the evaluation of ion-beam sputtering as a potentially useful surface roughening technique. Ion sources, similar to electron-bombardment ion thrusters designed for propulsive applications, are used to roughen the surfaces of various biocompatible alloys or polymer materials. These materials are typically used for dental implants, orthopedic prostheses, vascular prostheses, and artificial heart components. Masking techniques and resulting surface textures are described along with progress concerning evaluation of the biological response to the ion-beam-sputtered surfaces.

  12. The effects on bone cells of metal ions released from orthopaedic implants. A review

    PubMed Central

    Sansone, Valerio; Pagani, Davide; Melato, Marco

    2013-01-01

    Summary The increasing use of orthopedic implants and, in particular, of hip and knee joint replacements for young and active patients, has stimulated interest and concern regarding the chronic, long-term effects of the materials used. This review focuses on the current knowledge of the adverse biologic reactions to metal particles released from orthopaedic implants in vivo and in vitro. More specifically, the purpose of this article is to provide an overview of the current literature about the adverse effects of metal particles on bone cells and peri-implant bone. PMID:23858309

  13. [Clinical applicability of evidence-based orthopedics--a cross-sectional study of the quality of orthopedic evidence].

    PubMed

    Vavken, P; Culen, G; Dorotka, R

    2008-01-01

    The demand to routinely apply evidence-based methods in orthopedic surgery increases steadily. In order to do so, however, the validity and reliability of the "evidence" has to be scrutinized. The object of this study was to assess the quality of the most recent orthopedic evidence and to determine variables that have an influence on quality. All 2006 controlled trials from orthopedic journals with high impact factors were analysed in a cross-sectional study. A score based on the CONSORT statement was used to assess study quality. Selected variables were tested for their influence on the quality of the study. Two independent blinded observers reviewed 126 studies. The overall quality was moderate to high. The most neglected parameters were power analysis, intention-to-treat, and concealment. The participation of a methodologically trained investigator increases study quality significantly. There was no difference in study quality irrespective of whether or not there was statistically significant result. Using our quality score we were able show fairly good results for recent orthopedic studies. The most frequently neglected issues in orthopedic research are blinding, power analysis, and intention-to-treat. This may distort the results of clinical investigations considerably and, especially, lack of concealment causes false-positive findings. Our data show furthermore that participation of a methodologist significantly increases quality of the study and consequently strengthens the reliability of results.

  14. Chimeric Peptides as Implant Functionalization Agents for Titanium Alloy Implants with Antimicrobial Properties

    NASA Astrophysics Data System (ADS)

    Yucesoy, Deniz T.; Hnilova, Marketa; Boone, Kyle; Arnold, Paul M.; Snead, Malcolm L.; Tamerler, Candan

    2015-04-01

    Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMPs), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host and bacterial cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with AMPs can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated in vitro against three common human host infectious bacteria, Streptococcus mutans, Staphylococcus epidermidis, and Escherichia coli. In biological interactions such as occur on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore

  15. Chimeric peptides as implant functionalization agents for titanium alloy implants with antimicrobial properties.

    PubMed

    Yucesoy, Deniz T; Hnilova, Marketa; Boone, Kyle; Arnold, Paul M; Snead, Malcolm L; Tamerler, Candan

    2015-04-01

    Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMP's), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host- and bacterial- cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with antimicrobial peptides can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated in vitro against three common human host infectious bacteria, S. mutans, S. epidermidis , and E. coli . In biological interactions such as occurs on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore open up

  16. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws: A Phantom Study.

    PubMed

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M

    2015-08-01

    To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy.The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences.Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting.

  17. Improvement of corrosion resistance and antibacterial effect of NiTi orthopedic materials by chitosan and gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Ahmed, Rasha A.; Fadl-allah, Sahar A.; El-Bagoury, Nader; El-Rab, Sanaa M. F. Gad

    2014-02-01

    Biocomposite consists of gold nanoparticles (AuNPs) and a natural polymer as Chitosan (CS) was electrodeposited over NiTi alloy to improve biocompatibility, biostability, surface corrosion resistance and antibacterial effect for orthopedic implantation. The forming process and surface morphology of this biocomposite coats over NiTi alloy were studied. The results showed that the nm-scale gold particles were embedded in the composite forming compact, thick and smooth coat. Elemental analysis revealed significant less Ni ion release from the coated NiTi alloy compared with the uncoated one by 20 fold. Furthermore, the electrochemical corrosion measurements indicated that AuNPs/CS composite coat was effective for improving corrosion resistance in different immersion times and at all pH values, which suggests that the coated NiTi alloys have potential for orthopedic applications. Additionally, the efficiencies of the biocomposite coats for inhibiting bacterial growth indicate high antibacterial effect.

  18. Failure of Urological Implants in Spinal Cord Injury Patients due to Infection, Malfunction, and Implants Becoming Obsolete due to Medical Progress and Age-Related Changes in Human Body Making Implant Futile: Report of Three Cases.

    PubMed

    Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Selmi, Fahed; Mansour, Paul

    2013-01-01

    Any new clinical data, whether positive or negative, generated about a medical device should be published because health professionals should know which devices do not work, as well as those which do. We report three spinal cord injury patients in whom urological implants failed to work. In the first, paraplegic, patient, a sacral anterior root stimulator failed to produce erection, and a drug delivery system for intracavernosal administration of vasoactive drugs was therefore implanted; however, this implant never functioned (and, furthermore, such penile drug delivery systems to produce erection had effectively become obsolete following the advent of phosphodiesterase type 5 inhibitors). Subsequently, the sacral anterior root stimulator developed a malfunction and the patient therefore learned to perform self-catheterisation. In the second patient, also paraplegic, an artificial urinary sphincter was implanted but the patient developed a postoperative sacral pressure sore. Eight months later, a suprapubic cystostomy was performed as urethral catheterisation was very difficult. The pressure sore had not healed completely even after five years. In the third case, a sacral anterior root stimulator was implanted in a tetraplegic patient in whom, after five years, a penile sheath could not be fitted because of penile retraction. This patient was therefore established on urethral catheter drainage. Later, infection with Staphylococcus aureus around the receiver block necessitated its removal. In conclusion, spinal cord injury patients are at risk of developing pressure sores, wound infections, malfunction of implants, and the inability to use implants because of age-related changes, as well as running the risk of their implants becoming obsolete due to advances in medicine. Some surgical procedures such as dorsal rhizotomy are irreversible. Alternative treatments such as intermittent catheterisations may be less damaging than bladder stimulator in the long term.

  19. Association Between Helicobacter Pylori Infection and Long-term Outcome in Patients with Drug-eluting Stent Implantation

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Chen, Lei-Lei; Wang, De-Zhao; Chen, Bu-Xing

    2017-07-01

    To investigate the relationship between Helicobacter pylori (Hp) infection and the long-term outcome in acute coronary syndrome (ACS) patients with drug-eluting stent (DES) implantation and so as to explore the significance of Hp eradication therapy in preventing major adverse cardiac events (MACE) and upper gastrointestinal bleeding (UGIB). 539 ACS patients with DES implantation from January 1, 2010 to December 31, 2012 were analyzed. All the patients were divided into two groups according to the result of 13C urea breath test. 253 patients with Hp infection were put into group A (Hp+), and 286 cases without Hp infection were put into group B (Hp-). Demographic data was collected and all patients went through biochemical indicators and other routine blood examinations. We explored the correlations of Hp infection with MACE and UGIB after 3 to 5 years of follow-up using survival analysis. Survival analysis showed that Hp infection was a predictor of MACE and UGI. Sub-group analysis showed that patients with Hp eradication therapy had no relationship with MACE but had a lower rate of UGIB than those without Hp eradication therapy.

  20. A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science

    PubMed Central

    Nosouhian, Saeid; Rismanchian, Mansour; Sabzian, Roya; Shadmehr, Elham; Badrian, Hamid; Davoudi, Amin

    2015-01-01

    The purpose of this literature review was to screen the valuable published articles regarding to the impacts of mini-implants on orthodontic science, briefly. The searching category was performed on the Pubmed using MeSH words such as “dental (mini) implants, orthodontic anchorage procedures, and orthodontic appliances.” After preliminary sketch, they were grouped as follow: Those evaluating (a) common appliances for providing orthodontic anchorage, (b) biomechanical details of mini-implants and their insertion, (c) clinical application of mini-implants for orthognathic treatments, (d) limitations and possible complications. In conclusion, mini-implant evolved the orthodontic treatment plans and compromised the required orthognathic surgery. Malocclusion treatment and pure orthodontic or orthopedic movements in the three-dimensions have become recently possible by using mini-implant to provide skeletal anchorage. PMID:26225113

  1. SPECT/CT imaging in general orthopedic practice.

    PubMed

    Scharf, Stephen

    2009-09-01

    The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.

  2. Evaluation of Osseous Integration of PVD-Silver-Coated Hip Prostheses in a Canine Model

    PubMed Central

    Hauschild, Gregor; Hardes, Jendrik; Gosheger, Georg; Blaske, Franziska; Wehe, Christoph; Karst, Uwe; Höll, Steffen

    2015-01-01

    Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (mega)prostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition-) silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb) and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses. PMID:25695057

  3. [Research and analysis to Shui nationality medicine treatment orthopedics & traumatology].

    PubMed

    Hu, Jian-Shan; Li, Pu; Yang, Yong; Chen, Xin-Chun; Lin, Li

    2013-05-01

    To investigated Shui nationality folk medicine's awareness to orthopedics & traumatology, the history of orthopedics & traumatology treatment, Shui nationality folk doctors' practicing medicine, heritage, diagnosis and treatment methods and tools, etc, through investigated drug resources category and distribution characteristics of Shui nationality medicine to orthopedics & traumatology treatment, explored and finished Shui nationality medicine orthopedics & traumatology treatment theoretical system. After more than 5 years' exploration and finishing, preliminarily formed the theoretical system framework and medicine application characteristics of Shui nationality medicine treating orthopedics & traumatology. Shui nationality medicine treatment orthopedics & traumatology has distinctive national style, and worthy to further exploration and research.

  4. Cochlear implantation in children with congenital cytomegalovirus infection accompanied by psycho-neurological disorders.

    PubMed

    Yamazaki, Hiroshi; Yamamoto, Rinko; Moroto, Saburo; Yamazaki, Tomoko; Fujiwara, Keizo; Nakai, Masako; Ito, Juichi; Naito, Yasushi

    2012-04-01

    Cochlear implantation was effective for deaf children with congenital cytomegalovirus (CMV) infection, but their cochlear implant (CI) outcomes were often impaired, depending on the types of CMV-associated psycho-neurological disorders. Evaluation of cognitive development and autistic tendency of implantees might be useful to predict their CI outcomes. To reveal the influence of CMV-associated psycho-neurological disorders on CI outcomes. This was a retrospective evaluation of 11 implantees with congenital CMV infection (CMV-CIs) and 14 implantees with autosomal recessive hearing loss (genetic-CIs). Nine of 11 CMV-CIs suffered from psycho-neurological disorders; one from attention deficit hyperactivity disorder, two from pervasive developmental disorder, and six from mental retardation. Aided hearing thresholds with CIs in the two groups did not differ, but two autistic and two mentally retarded CMV-CIs showed significantly low scores in speech discrimination tests. Language-Social (L-S) developmental quotients (DQs) evaluated by the Kyoto Scale of Psychological development were improved after the implantation in both groups, but the postoperative increase of L-S DQs was significantly smaller in the CMV-CIs than that of genetic-CIs. Interestingly, the postoperative L-S and Cognitive-Adaptive (C-A) DQs showed statistically significant correlation in all cases except for two autistic CMV-CIs whose L-S DQs were much lower than those expected from their C-A DQs.

  5. Cochlear implants and medical tourism.

    PubMed

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  6. Metal TiO2 Nanotube Layers for the Treatment of Dental Implant Infections.

    PubMed

    Roguska, Agata; Belcarz, Anna; Zalewska, Justyna; Hołdyński, Marcin; Andrzejczuk, Mariusz; Pisarek, Marcin; Ginalska, Grazyna

    2018-05-23

    Titanium oxide nanotube layers with silver and zinc nanoparticles are attracting increasing attention in the design of bone and dental implants due to their antimicrobial potential and their ability to control host cell adhesion, growth, and differentiation. However, recent reports indicate that the etiology of dental infections is more complex than has been previously considered. Therefore, the antimicrobial potential of dental implants should be evaluated against at least several different microorganisms cooperating in human mouth colonization. In this study, Ag and Zn nanoparticles incorporated into titanium oxide nanotubular layers were studied with regard to how they affect Candida albicans, Candida parapsilosis, and Streptococcus mutans. Layers of titanium oxide nanotubes with an average diameter of 110 nm were fabricated by electrochemical anodization, annealed at 650 °C, and modified with approx. 5 wt % Ag or Zn nanoparticles. The surfaces were examined with the scanning electron microscopy-energy dispersive X-ray analysis, scanning transmission electron microscopy, and X-ray photoelectron spectroscopy techniques and subjected to evaluation of microbial-killing and microbial adhesion-inhibiting potency. In a 1.5 h long adhesion test, the samples were found more effective toward yeast strains than toward S. mutans. In a release-killing test, the microorganisms were almost completely eliminated by the samples, either within 3 h of contact (for S. mutans) or 24 h of contact (for both yeast strains). Although further improvement is advisable, it seems that Ag and Zn nanoparticles incorporated into TiO 2 nanotubular surfaces provide a powerful tool for reducing the incidence of bone implant infections. Their high bidirectional activity (against both Candida species and S. mutans) makes the layers tested particularly promising for the design of dental implants.

  7. Antibiotic susceptibility of Propionibacterium acnes isolated from orthopaedic implant-associated infections.

    PubMed

    Khassebaf, Jasmine; Hellmark, Bengt; Davidsson, Sabina; Unemo, Magnus; Nilsdotter-Augustinsson, Åsa; Söderquist, Bo

    2015-04-01

    Prosthetic joint infections (PJIs) caused by Propionibacterium acnes account for a larger proportion of the total number of PJIs than previously assumed and thus knowledge of the antimicrobial susceptibility patterns of P. acnes is of great value in everyday clinical practice. Using Etest, the present study investigated the susceptibility of 55 clinical isolates of P. acnes, obtained from orthopaedic implant-associated infections of the knee joint (n = 5), hip joint (n = 17), and shoulder joint (n = 33), to eight antimicrobial agents: benzylpenicillin, clindamycin, metronidazole, fusidic acid, doxycycline, moxifloxacin, linezolid and rifampicin. Synergy testing was also conducted, in which rifampicin was combined with each of the remaining seven antibiotics. All isolates (n = 55) were susceptible to most of the antibiotics tested, with the exception of 100% resistance to metronidazole, five (9.1%) isolates displaying decreased susceptibility to clindamycin, and one (1.8%) to moxifloxacin. None of the antimicrobial agents investigated were synergistic with each other when combined and nine isolates were antagonistic for various antimicrobial combinations. The majority of the antimicrobial combinations had an indifferent effect on the isolates of P. acnes. However, the combination of rifampicin and benzylpenicillin showed an additive effect on nearly half of the isolates. Almost all P. acnes, isolated from orthopaedic implant-associated infections, predominantly PJIs, were susceptible to the antibiotics tested, with the exception of complete resistance to metronidazole. Synergy test could not demonstrate any synergistic effect but additive effects were found when combining various antibiotics. Antagonistic effects were rare. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Engineering Orthopedic Tissue Interfaces

    PubMed Central

    Yang, Peter J.

    2009-01-01

    While a wide variety of approaches to engineering orthopedic tissues have been proposed, less attention has been paid to the interfaces, the specialized areas that connect two tissues of different biochemical and mechanical properties. The interface tissue plays an important role in transitioning mechanical load between disparate tissues. Thus, the relatively new field of interfacial tissue engineering presents new challenges—to not only consider the regeneration of individual orthopedic tissues, but also to design the biochemical and cellular composition of the linking tissue. Approaches to interfacial tissue engineering may be distinguished based on if the goal is to recreate the interface itself, or generate an entire integrated tissue unit (such as an osteochondral plug). As background for future efforts in engineering orthopedic interfaces, a brief review of the biology and mechanics of each interface (cartilage–bone, ligament–bone, meniscus–bone, and muscle–tendon) is presented, followed by an overview of the state-of-the-art in engineering each tissue, including advances and challenges specific to regenerating the interfaces. PMID:19231983

  9. Campylobacter Infections

    MedlinePlus

    ... Life Family Life Family Life Medical Home Family Dynamics Media Work & Play Getting Involved in Your Community ... and Urinary Tract Glands & Growth Head Neck & Nervous System Heart Infections Learning Disabilities Obesity Orthopedic Prevention Sexually ...

  10. Surface and corrosion characteristics of carbon plasma implanted and deposited nickel-titanium alloy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poon, R.W.Y.; Liu, X.Y.; Chung, C.Y.

    2005-05-01

    Nickel-titanium shape memory alloys (NiTi) are potentially useful in orthopedic implants on account of their super-elastic and shape memory properties. However, the materials are prone to surface corrosion and the most common problem is out-diffusion of harmful Ni ions from the substrate into body tissues and fluids. In order to improve the corrosion resistance and related surface properties, we used the technique of plasma immersion ion implantation and deposition to deposit an amorphous hydrogenated carbon coating onto NiTi and implant carbon into NiTi. Both the deposited amorphous carbon film and carbon plasma implanted samples exhibit much improved corrosion resistances andmore » surface mechanical properties and possible mechanisms are suggested.« less

  11. Impact of a Musculoskeletal Clerkship on Orthopedic Surgery Applicant Diversity.

    PubMed

    London, Daniel A; Calfee, Ryan P; Boyer, Martin I

    Orthopedic surgery lacks racial and sexual diversity, which we hypothesized stems from absence of exposure to orthopedics during medical school. We conducted a study to determine whether diversity of matched orthopedic surgery residency applicants increased after introduction of a required third-year rotation. We compared 2 groups: precurriculum and postcurriculum. The postcurriculum group was exposed to a required 1-month musculoskeletal rotation during the third year of medical school. Comparisons were made of percentage of total students exposed to orthopedics, percentage who applied to and matched to orthopedic surgery, and proportion of women and underrepresented minorities. A prospective survey was used to determine when students chose orthopedics and what influenced their decisions. The required rotation increased the percentage of third-year students rotating on orthopedics (25%) with no change in application rate (6%). It also led to an 81% relative increase in the proportion of female applicants and a 101% relative increase in underrepresented minority applicants. According to survey data, 79% of students chose orthopedics during their third year, and 88% thought they were influenced by their rotation. A required third-year rotation exposes more medical students to orthopedics and increases the diversity of matching students.

  12. Lumbar arthrodesis infection by multi-resistant Klebsiella pneumoniae, successfully treated with implant retention and ceftazidime/avibactam.

    PubMed

    Rico-Nieto, A; Moreno-Ramos, F; Fernández-Baillo, N

    2018-04-07

    There are increasingly more patients with prosthetic implants (orthopaedic prostheses, lumbar instruments, osteosynthesis material). In the last decade, infections caused by carbapenem resistant Enterobacteriaceae have increased (bacteriaemia, abscesses, urinary tract infections...) with great difficulty in treatment and important associated comorbidity. We present the first case of infection of a lumbar instrumentation by Klebsiella pneumoniae producing carbapenemase D, OXA-48 type, and successfully treated. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. In vivo efficacy of a silicone–cationic steroid antimicrobial coating to prevent implant-related infection

    PubMed Central

    Williams, Dustin L.; Haymond, Bryan S.; Beck, James P.; Savage, Paul B.; Chaudhary, Vinod; Epperson, Richard T.; Kawaguchi, Brooke; Bloebaum, Roy D.

    2012-01-01

    Active release antimicrobial coatings for medical devices have been developed to prevent and treat biofilm implant-related infections. To date, only a handful of coatings have been put into clinical use, with limited success. In this study, a novel antimicrobial compound was incorporated into a silicone (polydimethylsiloxane or PDMS) polymer to develop a novel active release coating that addressed several limitations of current device coatings. The efficacy of this coating was optimized using an in vitro flow cells system, then translated to an animal model of a simulated Type IIIB open fracture wherein well-established biofilms were used as initial inocula. Results indicated that the novel coating was able to prevent infection in 100% (9/9) of animals that were treated with biofilms and the novel coating (treatment group). In contrast, 100% (9/9) of animals that were inoculated with biofilms and not treated with the coating (positive control), did develop infection. Nine animals were used as negative controls, i.e., those that were not treated with biofilms, and showed a rate of infection of 11% (1/9). Eight animals were treated with the novel coating only to determine its effect on host tissue. Results indicated that the novel active release coating may have significant promise for future application to prevent biofilm implant-related infections in patients. PMID:22940221

  14. Core Concepts: Orthopedic Intern Curriculum Boot Camp.

    PubMed

    Seeley, Mark A; Kazarian, Erick; King, Brandon; Biermann, Janet S; Carpenter, James E; Caird, Michelle S; Irwin, Todd A

    2016-01-01

    Orthopedic surgical interns must gain a broad array of clinical skills in a short time. However, recent changes in health care have limited resident-patient exposures. With the reported success of simulation training in the surgical literature, the American Board of Orthopaedic Surgery (ABOS) and Residency Review Committee for Orthopaedic Surgery have required that surgical simulation training be a component of the intern curricula in orthopedic surgical residencies. This study examined the short-term effectiveness of an orthopedic "intern boot camp" covering 7 of 17 simulation training concept modules published by the ABOS. Eight orthopedic post-graduate year 1 (PGY-1) residents (study group) completed a structured 3-month curriculum and were compared with 7 post-graduate year 2 (PGY-2) residents (comparison group) who had just completed their orthopedic surgical internship. Seven core skills were assessed using both task-specific and global rating scales. The PGY-1 residents demonstrated a statistically significant improvement in all 7 modules with respect to their task-specific pre-test scores: sterile technique (P=.001), wound closure (P<.001), knot tying (P=.017), casting and splinting (P<.001), arthrocentesis (P=.01), basics of internal fixation (P<.001), and compartment syndrome evaluation (P=.004). After the camp, PGY-1 and -2 scores in task-specific measures were not significantly different. A 3-month simulation-based boot camp instituted early in orthopedic internship elevated a variety of clinical skills to levels exhibited by PGY-2 residents. Copyright 2016, SLACK Incorporated.

  15. A computational method for comparing the behavior and possible failure of prosthetic implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nielsen, C.; Hollerbach, K.; Perfect, S.

    1995-05-01

    Prosthetic joint implants currently in use exhibit high Realistic computer modeling of prosthetic implants provides an opportunity for orthopedic biomechanics researchers and physicians to understand possible in vivo failure modes, without having to resort to lengthy and costly clinical trials. The research presented here is part of a larger effort to develop realistic models of implanted joint prostheses. The example used here is the thumb carpo-metacarpal (cmc) joint. The work, however, can be applied to any other human joints for which prosthetic implants have been designed. Preliminary results of prosthetic joint loading, without surrounding human tissue (i.e., simulating conditions undermore » which the prosthetic joint has not yet been implanted into the human joint), are presented, based on a three-dimensional, nonlinear finite element analysis of three different joint implant designs.« less

  16. Rationale for one stage exchange of infected hip replacement using uncemented implants and antibiotic impregnated bone graft.

    PubMed

    Winkler, Heinz

    2009-09-04

    Infection of a total hip replacement (THR) is considered a devastating complication, necessitating its complete removal and thorough debridement of the site. It is undoubted that one stage exchange, if successful, would provide the best benefit both for the patient and the society. Still the fear of re-infection dominates the surgeons decisions and in the majority of cases directs them to multiple stage protocols. However, there is no scientifically based argument for that practice. Successful eradication of infection with two stage procedures is reported to average 80% to 98%. On the other hand a literature review of Jackson and Schmalzried (CORR 2000) summarizing the results of 1,299 infected hip replacements treated with direct exchange (almost exclusively using antibiotic loaded cement), reports of 1,077 (83%) having been successful. The comparable results suggest, that the major factor for a successful outcome with traditional approaches may be found in the quality of surgical debridement and dead space management. Failures in all protocols seem to be caused by small fragments of bacterial colonies remaining after debridement, whereas neither systemic antibiotics nor antibiotic loaded bone cement (PMMA) have been able to improve the situation significantly. Reasons for failure may be found in the limited sensitivity of traditional bacterial culturing and reduced antibiotic susceptibility of involved pathogens, especially considering biofilm formation. Whenever a new prosthesis is implanted into a previously infected site the surgeon must be aware of increased risk of failure, both in single or two stage revisions. Eventual removal therefore should be easy with low risk of additional damage to the bony substance. On the other hand it should also have potential of a good long term result in case of success. Cemented revisions generally show inferior long term results compared to uncemented techniques; the addition of antibiotics to cement reduces its

  17. The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction.

    PubMed

    Gibon, Emmanuel; Córdova, Luis A; Lu, Laura; Lin, Tzu-Hua; Yao, Zhenyu; Hamadouche, Moussa; Goodman, Stuart B

    2017-08-01

    Novel evidence-based prosthetic designs and biomaterials facilitate the performance of highly successful joint replacement (JR) procedures. To achieve this goal, constructs must be durable, biomechanically sound, and avoid adverse local tissue reactions. Different biomaterials such as metals and their alloys, polymers, ceramics, and composites are currently used for JR implants. This review focuses on (1) the biological response to the different biomaterials used for TJR and (2) the chronic inflammatory and foreign-body response induced by byproducts of these biomaterials. A homeostatic state of bone and surrounding soft tissue with current biomaterials for JR can be achieved with mechanically stable, infection free and intact (as opposed to the release of particulate or ionic byproducts) implants. Adverse local tissue reactions (an acute/chronic inflammatory reaction, periprosthetic osteolysis, loosening and subsequent mechanical failure) may evolve when the latter conditions are not met. This article (Part 2 of 2) summarizes the biological response to the non-metallic materials commonly used for joint replacement including polyethylene, ceramics, and polymethylmethacrylate (PMMA), as well as the foreign body reaction to byproducts of these materials. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1685-1691, 2017. © 2016 Wiley Periodicals, Inc.

  18. Economic analysis of athletic team coverage by an orthopedic practice.

    PubMed

    Lombardi, Nicholas; Freedman, Kevin; Tucker, Brad; Austin, Luke; Eck, Brandon; Pepe, Matt; Tjoumakaris, Fotios

    2015-11-01

    Coverage of high school football by orthopedic sports medicine specialists is considered standard of care in many localities. Determining the economic viability of this endeavor has never been investigated. The primary purpose of the present investigation was to perform an economic analysis of local high school sports coverage by an orthopedic sports medicine practice. From January 2010 to June 2012, a prospective injury report database was used to collect sports injuries from five high school athletic programs covered by a single, private orthopedic sports medicine practice. Patients referred for orthopedic care were then tracked to determine expected cost of care (potential revenue). Evaluation and management codes and current procedure terminology codes were obtained to determine the value of physician visits and surgical care rendered. Overhead costs were calculated based on historical rates within our practice and incorporated to determine estimated profit. 19,165 athletic trainer contacts with athletes playing all sports, including both those 'on-field' and in the training room, resulted in 473 (2.5%) physician referrals. The covering orthopedic practice handled 89 (27.9%) of the orthopedic referrals. Of orthopedic physician referrals, 26 (5.4%) required orthopedic surgical treatment. The covering team practice handled 17/26 (65%) surgical cases. The total revenue collected by the covering team practice was $26,226.14. The overhead cost of treatment was $9441.41. Overall estimated profit of orthopedic visits and treatment during this period for the covering practice was $16,784.73. The covering team practice handled 28% of the orthopedic referrals, 65% of the surgical cases and captured 59% of the potential profit. An increase in physician referrals could increase the benefit for orthopedic surgeons.

  19. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment.

    PubMed

    Taniguchi, Naoya; Fujibayashi, Shunsuke; Takemoto, Mitsuru; Sasaki, Kiyoyuki; Otsuki, Bungo; Nakamura, Takashi; Matsushita, Tomiharu; Kokubo, Tadashi; Matsuda, Shuichi

    2016-02-01

    Selective laser melting (SLM) is an additive manufacturing technique with the ability to produce metallic scaffolds with accurately controlled pore size, porosity, and interconnectivity for orthopedic applications. However, the optimal pore structure of porous titanium manufactured by SLM remains unclear. In this study, we evaluated the effect of pore size with constant porosity on in vivo bone ingrowth in rabbits into porous titanium implants manufactured by SLM. Three porous titanium implants (with an intended porosity of 65% and pore sizes of 300, 600, and 900μm, designated the P300, P600, and P900 implants, respectively) were manufactured by SLM. A diamond lattice was adapted as the basic structure. Their porous structures were evaluated and verified using microfocus X-ray computed tomography. Their bone-implant fixation ability was evaluated by their implantation as porous-surfaced titanium plates into the cortical bone of the rabbit tibia. Bone ingrowth was evaluated by their implantation as cylindrical porous titanium implants into the cancellous bone of the rabbit femur for 2, 4, and 8weeks. The average pore sizes of the P300, P600, and P900 implants were 309, 632, and 956μm, respectively. The P600 implant demonstrated a significantly higher fixation ability at 2weeks than the other implants. After 4weeks, all models had sufficiently high fixation ability in a detaching test. Bone ingrowth into the P300 implant was lower than into the other implants at 4weeks. Because of its appropriate mechanical strength, high fixation ability, and rapid bone ingrowth, our results indicate that the pore structure of the P600 implant is a suitable porous structure for orthopedic implants manufactured by SLM. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. How Useful are Orthopedic Surgery Residency Web Pages?

    PubMed

    Oladeji, Lasun O; Yu, Jonathan C; Oladeji, Afolayan K; Ponce, Brent A

    2015-01-01

    Medical students interested in orthopedic surgery residency positions frequently use the Internet as a modality to gather information about individual residency programs. Students often invest a painstaking amount of time and effort in determining programs that they are interested in, and the Internet is central to this process. Numerous studies have concluded that program websites are a valuable resource for residency and fellowship applicants. The purpose of the present study was to provide an update on the web pages of academic orthopedic surgery departments in the United States and to rate their utility in providing information on quality of education, faculty and resident information, environment, and applicant information. We reviewed existing websites for the 156 departments or divisions of orthopedic surgery that are currently accredited for resident education by the Accreditation Council for Graduate Medical Education. Each website was assessed for quality of information regarding quality of education, faculty and resident information, environment, and applicant information. We noted that 152 of the 156 departments (97%) had functioning websites that could be accessed. There was high variability regarding the comprehensiveness of orthopedic residency websites. Most of the orthopedic websites provided information on conference, didactics, and resident rotations. Less than 50% of programs provided information on resident call schedules, resident or faculty research and publications, resident hometowns, or resident salary. There is a lack of consistency regarding the content presented on orthopedic residency websites. As the competition for orthopedic websites continues to increase, applicants flock to the Internet to learn more about orthopedic websites in greater number. A well-constructed website has the potential to increase the caliber of students applying to a said program. Copyright © 2015 Association of Program Directors in Surgery. Published by

  1. Biomaterials with Antibacterial and Osteoinductive Properties to Repair Infected Bone Defects.

    PubMed

    Lu, Haiping; Liu, Yi; Guo, Jing; Wu, Huiling; Wang, Jingxiao; Wu, Gang

    2016-03-03

    The repair of infected bone defects is still challenging in the fields of orthopedics, oral implantology and maxillofacial surgery. In these cases, the self-healing capacity of bone tissue can be significantly compromised by the large size of bone defects and the potential/active bacterial activity. Infected bone defects are conventionally treated by a systemic/local administration of antibiotics to control infection and a subsequent implantation of bone grafts, such as autografts and allografts. However, these treatment options are time-consuming and usually yield less optimal efficacy. To approach these problems, novel biomaterials with both antibacterial and osteoinductive properties have been developed. The antibacterial property can be conferred by antibiotics and other novel antibacterial biomaterials, such as silver nanoparticles. Bone morphogenetic proteins are used to functionalize the biomaterials with a potent osteoinductive property. By manipulating the carrying modes and release kinetics, these biomaterials are optimized to maximize their antibacterial and osteoinductive functions with minimized cytotoxicity. The findings, in the past decade, have shown a very promising application potential of the novel biomaterials with the dual functions in treating infected bone defects. In this review, we will summarize the current knowledge of novel biomaterials with both antibacterial and osteoinductive properties.

  2. Is orthopedics more competitive today than when my attending matched? An analysis of National Resident Matching Program data for orthopedic PGY1 applicants from 1984 to 2011.

    PubMed

    Karnes, Jonathan M; Mayerson, Joel L; Scharschmidt, Thomas J

    2014-01-01

    This study evaluated supply and demand trends for orthopedic postgraduate year 1 (PGY1) positions from 1984 to 2011 for the purpose of estimating national intercandidate competition over time. National Resident Matching Program (NRMP) data for orthopedic surgery from 1984 to 2011 were collected. Proxy variables including (total number of orthopedic applicants/number of orthopedic PGY1 positions), (number of US senior applicants to orthopedics/number of orthopedic PGY1 positions), (number of US seniors matching into orthopedics/number of US senior orthopedic applicants), (total number of matched orthopedic applicants/total number of orthopedic applicants), and (total number of US applicants who fail to match into orthopedics/total number of US senior applicants into orthopedics) as well as average United States Medical Licensing Examination Step 1 scores were used to gauge the level of competition between candidates and were compared over time. Academic medical center in the Midwestern United States. Medical professors and medical students. The NRMP data suggested that the number of positions per applicant decreased or remained stable since 1984 and that the percentage of applicants who did not match was no higher now than in the past. This finding was primarily because of the relative decrease in the ratio of applicants to available PGY1 positions, which stems from the number of positions increasing more rapidly than the number of applicants. The NRMP data from 1984 to 2011 supported our hypothesis that intercandidate competition intensity for orthopedic PGY1 positions has not increased over time. The misconception that orthopedics is becoming more competitive likely arises from the increased number of applications submitted per candidate and the resulting relative importance placed on objective criteria such as United States Medical Licensing Examination Step 1 scores when programs select interview cohorts. Copyright © 2014 Association of Program Directors in

  3. Skin lesions over the pocket area that may mimic cardiac implantable electronic device infection: A case series.

    PubMed

    Korantzopoulos, Panagiotis; Plakoutsi, Sofia; Florou, Elizabeth; Bechlioulis, Aris

    2018-05-21

    The early and correct diagnosis of cardiac implantable electronic device (CIED) infections is critical given that early aggressive treatment with complete removal of the system along with antimicrobial therapy dramatically improves outcomes. Pocket infection manifested by local signs of inflammation is the most common form of CIED infections. Conditions mimicking pocket infection have been described in the literature. These include various types of malignancy and rarely allergic reactions/contact dermatitis to pacemaker compounds. We aimed to describe skin lesions and disorders over the pocket area that mimic CIED infection. We present a series of 5 cases with skin lesions that mimic pocket infection. We document these cases with corresponding photographs. Most of them have not been described in this setting. We report the following cases of conditions that proved not to be CIED infection: One case of superficial cellulitis, one case of herpes zoster over the pocket area, one case of spontaneous bruising over the pocket a long time after implantation in a patient taking oral anticoagulation, and 2 cases of contact dermatitis due to prolonged postoperative application of povidone iodine. All cases had favorable outcome after conservative treatment and no CIED infection was developed during follow-up. Clinicians should be aware of rare conditions that mimic CIED infection. Incorrect diagnosis of these disorders may falsely lead to CIED extraction. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. A glass fiber-reinforced composite - bioactive glass cranioplasty implant: A case study of an early development stage implant removed due to a late infection.

    PubMed

    Posti, Jussi P; Piitulainen, Jaakko M; Hupa, Leena; Fagerlund, Susanne; Frantzén, Janek; Aitasalo, Kalle M J; Vuorinen, Ville; Serlo, Willy; Syrjänen, Stina; Vallittu, Pekka K

    2015-03-01

    This case study describes the properties of an early development stage bioactive glass containing fiber-reinforced composite calvarial implant with histology that has been in function for two years and three months. The patient is a 33-year old woman with a history of substance abuse, who sustained a severe traumatic brain injury later unsuccessfully treated with an autologous bone flap and a custom-made porous polyethylene implant. She was thereafter treated with developmental stage glass fiber-reinforced composite - bioactive glass implant. After two years and three months, the implant was removed due to an implant site infection. The implant was analyzed histologically, mechanically, and in terms of chemistry and dissolution of bioactive glass. Mechanical integrity of the load bearing fiber-reinforced composite part of the implant was not affected by the in vivo period. Bioactive glass particles demonstrated surface layers of hydroxyapatite like mineral and dissolution, and related increase of pH was considerably less after two and three months period than that for fresh bioactive glass. There was a difference in the histology of the tissues inside the implant areas near to the margin of the implant that absorbed blood during implant installation surgery, showed fibrous tissue with blood vessels, osteoblasts, collagenous fibers with osteoid formation, and tiny clusters of more mature hard tissue. In the center of the implant, where there was less absorbed blood, only fibrous tissue was observed. This finding is in line with the combined positron emission tomography - computed tomography examination with (18F)-fluoride marker, which demonstrated activity of the mineralizing bone by osteoblasts especially at the area near to the margin of the implant 10 months after implantation. Based on these promising reactions found in the bioactive glass containing fiber-reinforced composite implant that has been implanted for two years and three months, calvarial

  5. Biodegradable/biocompatible coated metal implants for orthopedic applications.

    PubMed

    Saleh, Mohamed M; Touny, A H; Al-Omair, Mohammed A; Saleh, M M

    2016-05-12

    Biocompatible metals have been suggested as revolutionary biomaterials for bone-grafting therapies. Although metals and their alloys are widely and successfully used in producing biomedical implants due to their good mechanical properties and corrosion resistance, they have a lack in bioactivity. Therefore coating of the metal surface with calcium phosphates (CaP) is a benign way to achieve well bioactivity and get controlled corrosion properties. The biocompatibility and bioactivity calcium phosphates (CaP) in bone growth were guided them to biomedical treatment of bone defects and fractures. Many techniques have been used for fabrication of CaP coatings on metal substrates such as magnesium and titanium. The present review will focus on the synthesis of CaP and their relative forms using different techniques especially electrochemical techniques. The latter has always been known of its unique way of optimizing the process parameters that led to a control in the structure and characteristics of the produced materials.

  6. Role of fluconazole in the long-term suppressive therapy of fungal infections in patients with artificial implants.

    PubMed

    Penk, A; Pittrow, L

    1999-12-01

    With the increased use of artificial implants the management of related infections has become an important challenge. Normally an infected implant would be removed. In many cases this might be contraindicated and drug treatment remains as the only alternative. As microbiological eradication is often impossible, especially in fungal infections at artificial implants (FIAI) long-term suppressive therapy might be required. The objective of this study was to determine the therapeutic value of fluconazole (F) in the management of FIAI. Clinical data of 56 patients (pts) with proven or suspected fungal infections and artificial implants (FIAI) subsequently treated with F were analyzed retrospectively. FIAI caused by species with intrinsic resistance to F have been excluded from the study. The following implants were involved: prosthetic valve endocarditis (PVE) 25 pts (44.6%), intraocular lenses (IL) 9 pts (16.1%), ventriculoperitoneal shunts (VPS) 6 pts (10.7%), knee prostheses (KP) 5 pts (8.9%), biliary stents (BS) 4 pts (7.1 %), venous access devices (VAS) 3 pts (5.4%), urinary stents (US) 2 pts (3.6%), breast implant and pacemaker 1 patient (1.8%) each. Underlying diseases were valve insufficiency (in PVE), cataract surgery (in IL), prematurity in newborns (in VPS), arthrosis (in KP), biliary obstruction (in BS), cystic fibrosis (in VAS), and obstructive renal calculi (in US). Candida species (C. spp.) were the most frequently detected causative agents with C. parapsilosis as the leading cause (n = 19; 33.9%). Furthermore C. albicans (n = 15; 26.8%), C. spp. and fungi not further specified (n = 8; 14.3%), C. tropicalis (n = 3; 5.4%), C. glabrata (n = 3; 5.4%), and C. lusitaniae (n = 1; 1.8%) were identified. Acremonium kiliense has been detected in 4 pts (7.1%), Cryptococcus neoformans in 2 pts (3.6 %). Histoplasma capsulatum was identified in 1 patient (1.8%). The maximum duration of treatment with F was lifelong with a maximum recorded duration of 4,5 years. The

  7. Reducing bacterial contamination in an Orthopedic Theatre ventilated by natural ventilation, in a Developing Country.

    PubMed

    Thomas, Stephanie; Palmer, Rish; Phillipo, Edward; Chipungu, Geoffrey

    2016-05-31

    All surgical procedures have the potential for infection and some of the main sources are contamination from airborne particles, theatre personnel and the theatre environment.  There is strong evidence that the use of ultra-clean air flow systems in orthopedic operating theatres reduces the incidence of deep sepsis after surgery. In the developing world however, this is often an unrealistic solution. The aim of this study was to establish baseline levels of contamination in a working orthopedic theatre, at the Queen Elizabeth Central Hospital, Blantyre, Malawi. To feedback results to the theatre team, promote infection prevention discussion and work with the team to implement workable and realistic goals to improve the intra-operative environment. Samples were collected from theatre equipment available at the time of surgery, from theatre water and theatre air using passive air sampling techniques. Samples were immediately transferred to the Central Microbiology Laboratory for culture on basic culture media. Bacterial contamination of theatre equipment, intra-operative theatre air and water was detected. Results were discussed with the theatre and infection prevention team who were receptive to feedback with regards to infection prevention strategies and keen to develop simple measures which could be put in place to change practice. In this setting, we suggest that implementing workable and realistic goals such as, establishing baseline rates of bacterial contamination and introduction of strict protocols for asepsis and theatre etiquette, may reduce bacterial contamination rates and subsequent intra-operative infection in the absence of expensive engineering solutions.

  8. Characteristics of Orthopedic Publications in High-Impact General Medical Journals.

    PubMed

    Nwachukwu, Benedict U; Kahlenberg, Cynthia A; Lehman, Jason D; Lyman, Stephen; Marx, Robert G

    2017-05-01

    Orthopedic studies are occasionally published in high-impact general medical journals; these studies are often given high visibility and have significant potential to impact health care policy and inform clinical decision-making. The purpose of this review was to investigate the characteristics of operative orthopedic studies published in high-impact medical journals. The number of orthopedic studies published in high-impact medical journals is relatively low; however, these studies demonstrate methodological characteristics that may bias toward nonoperative treatment. Careful analysis and interpretation of orthopedic studies published in these journals is warranted. [Orthopedics. 2017; 40(3):e405-e412.]. Copyright 2017, SLACK Incorporated.

  9. Arthroscopic training resources in orthopedic resident education.

    PubMed

    Koehler, Ryan; John, Tamara; Lawler, Jeffrey; Moorman, Claude; Nicandri, Gregg

    2015-02-01

    The purpose of this study was to determine the frequency of use, perceived effectiveness, and preference for arthroscopic surgical skill training resources. An electronic survey was sent to orthopedics residents, residency program directors, and orthopedic sports medicine attending physicians in the United States. The frequency and perceived effectiveness of 10 types of adjunctive arthroscopic skills training was assessed. Residents and faculty members were asked to rate their confidence in resident ability to perform common arthroscopic procedures. Surveys were completed by 40 of 152 (26.3%) orthopedic residency program directors, 70 of 426 (16.4%) sports medicine faculty, and 235 of 3,170 (7.4%) orthopedic residents. The use of adjunctive methods of training varied from only 9.8% of programs with virtual reality training to 80.5% of programs that used reading of published materials to develop arthroscopic skill. Practice on cadaveric specimens was viewed as the most effective and preferred adjunctive method of training. Residents trained on cadaveric specimens reported increased confidence in their ability to perform arthroscopic procedures. The resources for developing arthroscopic surgical skill vary considerably across orthopedic residency programs in the United States. Adjunctive training methods were perceived to be effective at supplementing traditional training in the operating room. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Osseointegration of Plateau Root Form Implants: Unique Healing Pathway Leading to Haversian-Like Long-Term Morphology.

    PubMed

    Coelho, Paulo G; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Gil, Luis F; Tovar, Nick; Jimbo, Ryo; Neiva, Rodrigo; Bonfante, Estevam A

    2015-01-01

    Endosteal dental implants have been utilized as anchors for dental and orthopedic rehabilitations for decades with one of the highest treatment success rates in medicine. Such success is due to the phenomenon of osseointegration where after the implant surgical placement, bone healing results into an intimate contact between bone and implant surface. While osseointegration is an established phenomenon, the route which osseointegration occurs around endosteal implants is related to various implant design factors including surgical instrumentation and implant macro, micro, and nanometer scale geometry. In an implant system where void spaces (healing chambers) are present between the implant and bone immediately after placement, its inherent bone healing pathway results in unique opportunities to accelerate the osseointegration phenomenon at the short-term and its maintenance on the long-term through a haversian-like bone morphology and mechanical properties.

  11. Bibliometric analysis of the orthopedic literature.

    PubMed

    Hui, Zhaoyang; Yi, Zhongmei; Peng, Jun

    2013-10-01

    Bibliometric indicators are used to assess research performance. The goal of this study was to explore publication output to construct a picture of orthopedics that may be beneficial to researchers and orthopedic specialists. All orthopedics articles published in 61 journals from 2000 to 2011 were retrieved from the Science Citation Index Expanded database. The numbers of articles, citations, authors, institutions, and journals were analyzed and subjected to quantitative and qualitative comparisons. The number of published orthopedics articles increased between 2000 and 2011. Articles published by authors from the United States always ranked first in number, although the United States' share is decreasing in the world literature. Authors from the United States published the most-cited articles and the most articles in journals with top-10 impact factors; moreover, the United States also had the greatest share of experts and highly ranked institutions. The United Kingdom, Germany, and Japan were always within the world's top 4 in terms of numbers of articles and citations. The shares of Germany, South Korea, and China among total orthopedics articles increased, especially that of China. In 2011, China ranked the fifth in the world, with its world share increasing from 0.64% in 2000 to 5.05% in 2011. However, China lags behind in average citations per article, top research institutions, and most prolific authors. According to the total citations per article, the University of Pittsburgh, Harvard University, and the Hospital for Special Surgery were the most prolific institutions. Copyright 2013, SLACK Incorporated.

  12. Middle Ear Infections

    MedlinePlus

    ... Life Family Life Family Life Medical Home Family Dynamics Media Work & Play Getting Involved in Your Community ... and Urinary Tract Glands & Growth Head Neck & Nervous System Heart Infections Learning Disabilities Obesity Orthopedic Prevention Sexually ...

  13. Factors affecting orthopedic residency selection: a cross-sectional survey.

    PubMed

    Strelzow, Jason; Petretta, Robert; Broekhuyse, Henry M

    2017-06-01

    Annually, orthopedic residency programs rank and recruit the best possible candidates. Little evidence exists identifying factors that potential candidates use to select their career paths. Recent literature from nonsurgical programs suggests hospital, social and program-based factors influence program selection. We sought to determine what factors influence the choice of an orthopedic career and a candidate's choice of orthopedic residency program. We surveyed medical student applicants to orthopedic programs and current Canadian orthopedic surgery residents (postgraduate year [PGY] 1-5). The confidential online survey focused on 3 broad categories of program selection: educational, program cohesion and noneducation factors. Questions were graded on a Likert Scale and tailed for mean scores. In total, 139 residents from 11 of 17 Canadian orthopedic programs (49% response rate) and 23 medical student applicants (88% response rate) completed our survey. Orthopedic electives and mandatory rotations were reported by 71% of participants as somewhat or very important to their career choice. Collegiality among residents (4.70 ± 0.6), program being the "right fit" (4.65 ± 0.53) and current resident satisfaction with their chosen program (4.63 ±0.66) were ranked with the highest mean scores on a 5-point Likert scale. There are several modifiable factors that residency programs may use to attract applicants, including early availability of clerkship rotations and a strong mentorship environment emphasizing both resident-resident and resident-staff cohesion. Desirable residency programs should develop early access to surgical and operative skills. These must be balanced with a continued emphasis on top-level orthopedic training.

  14. Medical students' and interns' interest in orthopedic surgery: the gender factor.

    PubMed

    Schroeder, Joshua E; Zisk-Rony, Rachel Y; Liebergall, Meir; Tandeter, Howard; Kaplan, Leon; Weiss, Yoram G; Weissman, Charles

    2014-01-01

    There is an extremely small proportion of female medical students choosing to specialize in orthopedic surgery. The aim of the study was to assess medical students' and interns' interests and perceptions of orthopedic surgery and explore why women are not interested in orthopedic surgery. Questionnaires were distributed to final-year medical students and interns assessing their interests and perception of orthopedic surgery. Final-year medical students and interns. Responses were obtained from 317 students and 199 interns. Among the medical students, 15% were interested in orthopedic surgery, but only 2% were women. Both male and female students perceived orthopedics as an "action"-packed, procedure-based profession, providing instant gratification, time in the operating room, high income, and the option for private practice. Female medical students considered it boring. Among interns, 11% were interested in orthopedic surgery; however, only 2% were women. When compared with the interns who were not interested in orthopedic surgery, a greater number of the interns interested in orthopedic surgery rated time with family and a procedure-intensive profession as important. Female students and interns were also interested in other surgical fields. The increasing majority of women among medical students will reshape the future of physician workforce by dictating changes in workforce participation, working conditions, and intercollegial relationships. Orthopedic surgery will need to adapt to these realities. Published by Elsevier Inc.

  15. Artifacts Quantification of Metal Implants in MRI

    NASA Astrophysics Data System (ADS)

    Vrachnis, I. N.; Vlachopoulos, G. F.; Maris, T. G.; Costaridou, L. I.

    2017-11-01

    The presence of materials with different magnetic properties, such as metal implants, causes distortion of the magnetic field locally, resulting in signal voids and pile ups, i.e. susceptibility artifacts in MRI. Quantitative and unbiased measurement of the artifact is prerequisite for optimization of acquisition parameters. In this study an image gradient based segmentation method is proposed for susceptibility artifact quantification. The method captures abrupt signal alterations by calculation of the image gradient. Then the artifact is quantified in terms of its extent by an automated cross entropy thresholding method as image area percentage. The proposed method for artifact quantification was tested in phantoms containing two orthopedic implants with significantly different magnetic permeabilities. The method was compared against a method proposed in the literature, considered as a reference, demonstrating moderate to good correlation (Spearman’s rho = 0.62 and 0.802 in case of titanium and stainless steel implants). The automated character of the proposed quantification method seems promising towards MRI acquisition parameter optimization.

  16. Hydroxyapatite electrodeposition on anodized titanium nanotubes for orthopedic applications

    NASA Astrophysics Data System (ADS)

    Parcharoen, Yardnapar; Kajitvichyanukul, Puangrat; Sirivisoot, Sirinrath; Termsuksawad, Preecha

    2014-08-01

    Nanotubes modification for orthopedic implants has shown interesting biological performances (such as improving cell adhesion, cell differentiation, and enhancing osseointegration). The purpose of this study is to investigate effect of titanium dioxide (TiO2) nanotube feature on performance of hydroxyapatite-coated titanium (Ti) bone implants. TiO2 nanotubes were prepared by anodization using ammonium fluoride electrolyte (NH4F) with and without modifiers (PEG400 and Glycerol) at various potential forms, and times. After anodization, the nanotubes were subsequently annealed. TiO2 nanotubes were characterized by scanning electron microscope and X-ray diffractometer. The amorphous to anatase transformation due to annealing was observed. Smooth and highly organized TiO2 nanotubes were found when high viscous electrolyte, NH4F in glycerol, was used. Negative voltage (-4 V) during anodization was confirmed to increase nanotube thickness. Length of the TiO2 nanotubes was significantly increased by times. The TiO2 nanotube was electrodeposited with hydroxyapatite (HA) and its adhesion was estimated by adhesive tape test. The result showed that nanotubes with the tube length of 560 nm showed excellent adhesion. The coated HA were tested for biological test by live/dead cell straining. HA coated on TiO2 nanotubes showed higher cells density, higher live cells, and more spreading of MC3T3-E1 cells than that growing on titanium plate surface.

  17. Enhancing the mechanical and biological performance of a metallic biomaterial for orthopedic applications through changes in the surface oxide layer by nanocrystalline surface modification.

    PubMed

    Bahl, Sumit; Shreyas, P; Trishul, M A; Suwas, Satyam; Chatterjee, Kaushik

    2015-05-07

    Nanostructured metals are a promising class of biomaterials for application in orthopedics to improve the mechanical performance and biological response for increasing the life of biomedical implants. Surface mechanical attrition treatment (SMAT) is an efficient way of engineering nanocrystalline surfaces on metal substrates. In this work, 316L stainless steel (SS), a widely used orthopedic biomaterial, was subjected to SMAT to generate a nanocrystalline surface. Surface nanocrystallization modified the nature of the oxide layer present on the surface. It increased the corrosion-fatigue strength in saline by 50%. This increase in strength is attributed to a thicker oxide layer, residual compressive stresses, high strength of the surface layer, and lower propensity for intergranular corrosion in the nanocrystalline layer. Nanocrystallization also enhanced osteoblast attachment and proliferation. Intriguingly, wettability and surface roughness, the key parameters widely acknowledged for controlling the cellular response remained unchanged after nanocrystallization. The observed cellular behavior is explained in terms of the changes in electronic properties of the semiconducting passive oxide film present on the surface of 316L SS. Nanocrystallization increased the charge carrier density of the n-type oxide film likely preventing denaturation of the adsorbed cell-adhesive proteins such as fibronectin. In addition, a net positive charge developed on the otherwise neutral oxide layer, which is known to facilitate cellular adhesion. The role of changes in the electronic properties of the oxide films on metal substrates is thus highlighted in this work. This study demonstrates the advantages of nanocrystalline surface modification by SMAT for processing metallic biomaterials used in orthopedic implants.

  18. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review.

    PubMed

    Matusiewicz, Henryk

    2014-06-01

    Metal ion release from metallic materials, e.g. metallic alloys and pure metals, implanted into the human body in dental and orthopedic surgery is becoming a major cause for concern. This review briefly provides an overview of both metallic alloys and pure metals used in implant materials in dental and orthopedic surgery. Additionally, a short section is dedicated to important biomaterials and their corrosive behavior in both real solutions and various types of media that model human biological fluids and tissues. The present review gives an overview of analytical methods, techniques and different approaches applied to the measurement of in vivo trace metals released into body fluids and tissues from patients carrying metal-on-metal prostheses and metal dental implants. Reference levels of ion concentrations in body fluids and tissues that have been determined by a host of studies are compiled, reviewed and presented in this paper. Finally, a collection of published clinical data on in vivo released trace metals from metallic medical implants is included. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. Perspectives of Orthopedic Surgeons on Racial/Ethnic Disparities in Care.

    PubMed

    Adelani, Muyibat A; O'Connor, Mary I

    2017-08-01

    Racial/ethnic disparities in healthcare, including orthopedics, have been extensively documented. However, the level of knowledge among orthopedic surgeons regarding racial/ethnic disparities is unknown. The purpose of this study is to determine the views of orthopedic surgeons on (1) the extent of racial/ethnic disparities in orthopedic care, (2) patient and system factors that may contribute, and (3) the potential role of orthopedic surgeons in the reduction of disparities. Three hundred five members of the American Orthopaedic Association completed a survey to assess their knowledge of racial/ethnic disparities and their perceptions about the underlying causes. Twelve percent of respondents believe that patients often receive different care based on race/ethnicity in healthcare in general, while 9 % believe that differences exist in orthopedic care in general, 3 % believe that differences exist within their hospitals/clinics, and 1 % reported differences in their own practices. Despite this, 68 % acknowledge that there is evidence of disparities in orthopedic care. Fifty-one percent believe that a lack of insurance significantly contributes to disparities. Thirty-five percent believe that diversification of the orthopedic workforce would be a "very effective" strategy in addressing disparities, while 25 % percent believe that research would be "very effective" and 24 % believe that surgeon education would be "very effective." Awareness regarding racial/ethnic disparities in musculoskeletal care is low among orthopedic surgeons. Additionally, respondents were more likely to acknowledge disparities within the practices of others than their own. Increased diversity, research, and education may help improve knowledge of this problem.

  20. Factors affecting orthopedic residency selection: a cross-sectional survey

    PubMed Central

    Strelzow, Jason; Petretta, Robert; Broekhuyse, Henry M.

    2017-01-01

    Background Annually, orthopedic residency programs rank and recruit the best possible candidates. Little evidence exists identifying factors that potential candidates use to select their career paths. Recent literature from nonsurgical programs suggests hospital, social and program-based factors influence program selection. We sought to determine what factors influence the choice of an orthopedic career and a candidate’s choice of orthopedic residency program. Methods We surveyed medical student applicants to orthopedic programs and current Canadian orthopedic surgery residents (postgraduate year [PGY] 1–5). The confidential online survey focused on 3 broad categories of program selection: educational, program cohesion and noneducation factors. Questions were graded on a Likert Scale and tailed for mean scores. Results In total, 139 residents from 11 of 17 Canadian orthopedic programs (49% response rate) and 23 medical student applicants (88% response rate) completed our survey. Orthopedic electives and mandatory rotations were reported by 71% of participants as somewhat or very important to their career choice. Collegiality among residents (4.70 ± 0.6), program being the “right fit” (4.65 ± 0.53) and current resident satisfaction with their chosen program (4.63 ±0.66) were ranked with the highest mean scores on a 5-point Likert scale. Conclusion There are several modifiable factors that residency programs may use to attract applicants, including early availability of clerkship rotations and a strong mentorship environment emphasizing both resident–resident and resident–staff cohesion. Desirable residency programs should develop early access to surgical and operative skills. These must be balanced with a continued emphasis on top-level orthopedic training. PMID:28327273

  1. About Implantable Contraception

    MedlinePlus

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español About Implantable Contraception KidsHealth / For Parents / About Implantable Contraception Print What ...

  2. Orthopedic injuries associated with backyard trampoline use in children.

    PubMed

    Black, G Brian; Amadeo, Ryan

    2003-06-01

    Trampolining on an outdoor oval or circular trampoline is a popular activity for children but is associated with a number of orthopedic injuries, especially in children between the ages of 5 and 15 years. In this paper we review the orthopedic injuries in children associated with backyard trampoline use, through our experience with a series of children admitted to the Winnipeg Children's Hospital, the only tertiary care pediatric centre in Manitoba. We reviewed the charts, x-ray films and operative reports for 80 children under 16 years old (mean 9 yr, with 14 [18%] children between 2 and 4 yr) with an orthopedic injury sustained when using a trampoline in the backyard. We noted the mechanism of injury and type and severity of orthopedic injury sustained. Fifty-two (65%) children were injured on the trampoline mat, and 24 (30%) were injured when they were ejected from the trampoline. Sixty (75%) children sustained a fracture or fracture-dislocation. Forty-eight (80%) orthopedic injuries occurred in the upper extremity. No child died as a result of a trampoline injury. The use of the "backyard" trampoline by young children can cause significant orthopedic injury.

  3. Orthopedic injuries associated with backyard trampoline use in children

    PubMed Central

    Black, G. Brian; Amadeo, Ryan

    2003-01-01

    Introduction Trampolining on an outdoor oval or circular trampoline is a popular activity for children but is associated with a number of orthopedic injuries, especially in children between the ages of 5 and 15 years. In this paper we review the orthopedic injuries in children associated with backyard trampoline use, through our experience with a series of children admitted to the Winnipeg Children's Hospital, the only tertiary care pediatric centre in Manitoba. Methods We reviewed the charts, x-ray films and operative reports for 80 children under 16 years old (mean 9 yr, with 14 [18%] children between 2 and 4 yr) with an orthopedic injury sustained when using a trampoline in the backyard. We noted the mechanism of injury and type and severity of orthopedic injury sustained. Results Fifty-two (65%) children were injured on the trampoline mat, and 24 (30%) were injured when they were ejected from the trampoline. Sixty (75%) children sustained a fracture or fracture-dislocation. Forty-eight (80%) orthopedic injuries occurred in the upper extremity. No child died as a result of a trampoline injury. Conclusion The use of the “backyard” trampoline by young children can cause significant orthopedic injury. PMID:12812242

  4. Infectious complications of pediatric cochlear implants are highly influenced by otitis media.

    PubMed

    Vila, Peter M; Ghogomu, Nsangou T; Odom-John, Audrey R; Hullar, Timothy E; Hirose, Keiko

    2017-06-01

    Determine the incidence of ear infections in cochlear implant patients, evaluate the contribution of otitis media to complications, describe the bacteriology of otitis media in the cochlear implant population, the treatment provided at our center, and the long term outcome. Data collected included age at implantation, history of otitis media or ear tubes, etiology of hearing loss, inner ear anatomy, postoperative infections, time to infection, route of antibiotic administration, and interventions for infections. Categories of infection were acute otitis media, otitis media with effusion, tube otorrhea, meningitis, scalp cellulitis, and infection at the implant site. Middle ear infections were diagnosed in 37% of implanted ears. Extension of middle ear infections into the implant site occurred in 2.8% of all implants (n = 16). Of the 16 infected devices, 10 were successfully treated with antibiotic therapy and did not require explantation. The retained implant group and explanted group both included some middle ear microbes such as Haemophilus influenzae and Streptococcus pneumoniae, as well as skin flora such as Staphylococcus aureus. Otitis media in pediatric cochlear implant patients is a common event and usually does not lead to complications of the cochlear implant. However, when the ear infection spreads to the scalp and the implant site, it is still possible to eliminate the infection using antibiotic therapy, particularly when treatment is directed to the specific organism that is recovered from the infected space and the duration and route of antibiotic treatment is carefully considered. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Optimization of Cell Adhesion on Mg Based Implant Materials by Pre-Incubation under Cell Culture Conditions

    PubMed Central

    Willumeit, Regine; Möhring, Anneke; Feyerabend, Frank

    2014-01-01

    Magnesium based implants could revolutionize applications where orthopedic implants such as nails, screws or bone plates are used because they are load bearing and degrade over time. This prevents a second surgery to remove conventional implants. To improve the biocompatibility we studied here if and for how long a pre-incubation of the material under cell culture conditions is favorable for cell attachment and proliferation. For two materials, Mg and Mg10Gd1Nd, we could show that 6 h pre-incubation are already enough to form a natural protective layer suitable for cell culture. PMID:24857908

  6. Optimization of cell adhesion on mg based implant materials by pre-incubation under cell culture conditions.

    PubMed

    Willumeit, Regine; Möhring, Anneke; Feyerabend, Frank

    2014-05-05

    Magnesium based implants could revolutionize applications where orthopedic implants such as nails, screws or bone plates are used because they are load bearing and degrade over time. This prevents a second surgery to remove conventional implants. To improve the biocompatibility we studied here if and for how long a pre-incubation of the material under cell culture conditions is favorable for cell attachment and proliferation. For two materials, Mg and Mg10Gd1Nd, we could show that 6 h pre-incubation are already enough to form a natural protective layer suitable for cell culture.

  7. Factors influencing uptake of contraceptive implants in the immediate postpartum period among HIV infected and uninfected women at two Kenyan District Hospitals.

    PubMed

    Shabiby, Mufida M; Karanja, Joseph G; Odawa, Francis; Kosgei, Rose; Kibore, Minnie W; Kiarie, James N; Kinuthia, John

    2015-08-19

    Family planning is a cost effective strategy for prevention of mother to child transmission of HIV and reduction of maternal/infant morbidity and mortality. Contraceptive implants are a safe, effective, long term and reversible family planning method whose use remains low in Kenya. We therefore set out to determine and compare the uptake, and factors influencing uptake of immediate postpartum contraceptive implants among HIV infected and uninfected women at two hospitals in Kenya. This cross sectional study targeted postpartum mothers at two Kenyan district hospitals (one urban and one rural). All participants received general family planning and method specific (Implant) counseling followed by immediate insertion of contraceptive implants to those who consented. The data was analyzed by descriptive analysis, T-test, Chi square tests and logistic regression. One hundred eighty-five participants were enrolled (91 HIV positive and 94 HIV negative) with a mean age of 26 years. HIV positive mothers were significantly older (27.5 years) than their HIV negative counterparts (24.5 years), P = 0.001. The two groups were comparable in education, employment, marital status and religious affiliation. Overall, the uptake of contraceptive implants in the immediate postpartum period was 50.3% and higher among HIV negative than HIV positive participants (57% vs. 43%, P = 0.046). Multivariate analysis revealed that a negative HIV status (P = 0.017) and prior knowledge of contraceptive implants (P = 0.001) were independently associated with increased uptake of contraceptive implants. There was a high uptake of immediate postpartum contraceptive implants among both HIV infected and un-infected women; efforts therefore need to be made in promoting this method of family planning in Kenya and providing this method to women in the immediate postpartum period so as to utilize this critical opportunity to increase uptake and reduce the high unmet need for family planning.

  8. 21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...

  9. 21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...

  10. Efficacy of antibiotic treatment of implant-associated Staphylococcus aureus infections with moxifloxacin, flucloxacillin, rifampin, and combination therapy: an animal study.

    PubMed

    Greimel, Felix; Scheuerer, Christine; Gessner, Andre; Simon, Michaela; Kalteis, Thomas; Grifka, Joachim; Benditz, Achim; Springorum, Hans-Robert; Schaumburger, Jens

    2017-01-01

    The efficacy of antibiotic monotherapy and combination therapy in the treatment of implant-associated infection by Staphylococcus aureus was evaluated in an animal study. The femoral medullary cavity of 66 male Wistar rats was contaminated with S. aureus (ATCC 29213) and a metal device was implanted, of which 61 could be evaluated. Six treatment groups were studied: flucloxacillin, flucloxacillin in combination with rifampin, moxifloxacin, moxifloxacin in combination with rifampin, rifampin, and a control group with aqua. The treatment was applied for 14 days. After euthanasia, the bacterial counts in the periprosthetic bone, the soft tissue, and the implant-associated biofilm were measured. Both antibiotic combination treatments (moxifloxacin plus rifampin and flucloxacillin plus rifampin) achieved a highly significant decrease in microbial counts in the bone and soft tissue and in the biofilm. Mono-antibiotic treatments with either moxifloxacin or flucloxacillin were unable to achieve a significant decrease in microbial counts in bone and soft tissue or the biofilm, whilst rifampin was able to reduce the counts significantly only in the biofilm. Antibiotic resistance was measured in 1/3 of the cases in the rifampin group, whereas no resistance was measured in all other groups. The results show that combinations of both moxifloxacin and flucloxacillin plus rifampin are adequate for the treatment of periprosthetic infections due to infections with S. aureus , whereas monotherapies are not effective or not applicable due to the rapid development of antibiotic resistance. Therefore, moxifloxacin is an effective alternative in combination with rifampin for the treatment of implant-associated infections.

  11. A New Culture of Transparency: Industry Payments to Orthopedic Surgeons.

    PubMed

    Lopez, Joseph; Ahmed, Rizwan; Bae, Sunjae; Hicks, Caitlin W; El Dafrawy, Mostafa; Osgood, Greg M; Segev, Dorry L

    2016-11-01

    Under the Physician Payments Sunshine Act, "payments or transfers of value" by biomedical companies to physicians must be disclosed through the Open Payments Program. Designed to provide transparency of financial transactions between medication and device manufacturers and health care providers, the Open Payments Program shows financial relationships between industry and health care providers. Awareness of this program is crucial because its interpretation or misinterpretation by patients, physicians, and the general public can affect patient care, clinical practice, and research. This study evaluated nonresearch payments by industry to orthopedic surgeons. A retrospective cross-sectional review of the first wave of Physician Payments Sunshine Act data (August through December 2013) was performed to characterize industry payments to orthopedic surgeons by subspecialty, amount, type, origin, and geographic distribution. During this 5-month period, orthopedic surgeons (n=14,828) received $107,666,826, which included 3% of those listed in the Open Payments Program and 23% of the total amount paid. Of orthopedic surgeons who received payment, 45% received less than $100 and 1% received $100,000 or more. Median payment (interquartile range) was $119 ($34-$636), and mean payment was $7261±95,887. The largest payment to an individual orthopedic surgeon was $7,849,711. The 2 largest payment categories were royalty or license fees (68%) and consulting fees (13%). During the study period, orthopedic surgeons had substantial financial ties to industry. Of orthopedic surgeons who received payments, the largest proportion (45%) received less than $100 and only 1% received large payments (≥$100,000). The Open Payments Program offers insight into industry payments to orthopedic surgeons. [Orthopedics. 2016; 39(6):e1058-e1062.]. Copyright 2016, SLACK Incorporated.

  12. A functionalized surface modification with vanadium nanoparticles of various valences against implant-associated bloodstream infection.

    PubMed

    Wang, Jiaxing; Zhou, Huaijuan; Guo, Geyong; Cheng, Tao; Peng, Xiaochun; Mao, Xin; Li, Jinhua; Zhang, Xianlong

    2017-01-01

    Bloodstream infection, especially with implants involved, is an often life-threatening condition with high mortality rates, imposing a heavy burden on patients and medical systems. Herein, we firstly deposited homogeneous vanadium metal, V 2 O 3 , VO 2 , and V 2 O 5 nanofilms on quartz glass by magnetron sputtering. Using these platforms, we further investigated the potential antimicrobial efficiency of these nano-VO x films and the interactions of human erythrocytes and bacteria (methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa ) with our samples in a novel cell-bacteria coculture model. It was demonstrated that these nano-VO x precipitated favorable antibacterial activity on both bacteria, especially on S. aureus , and this effect increased with higher vanadium valence. A possible mechanism accountable for these results might be elevated levels of vanadium-induced intracellular reactive oxygen species. More importantly, based on hemolysis assays, our nano-VO x films were found to be able to kill prokaryotic cells but were not toxic to mammalian cells, holding the potential for the prevention of implant-related hematogenous infections. As far as we know, this is the first report wherein such nano-VO x films have assisted human erythrocytes to combat bacteria in a valence-dependent manner. Additionally, vanadium ions were released from these nano-VO x films in a sustained manner, and low-valence films possessed better biocompatibility with human fibroblasts. This work may provide new insights for biomedical applications of inorganic vanadium compounds and attract growing attention in this field. From the perspective of surface modification and functionalization, this study holds promise to avail the prophylaxis of bloodstream infections involving implantable biomedical devices.

  13. A functionalized surface modification with vanadium nanoparticles of various valences against implant-associated bloodstream infection

    PubMed Central

    Wang, Jiaxing; Zhou, Huaijuan; Guo, Geyong; Cheng, Tao; Peng, Xiaochun; Mao, Xin; Li, Jinhua; Zhang, Xianlong

    2017-01-01

    Bloodstream infection, especially with implants involved, is an often life-threatening condition with high mortality rates, imposing a heavy burden on patients and medical systems. Herein, we firstly deposited homogeneous vanadium metal, V2O3, VO2, and V2O5 nanofilms on quartz glass by magnetron sputtering. Using these platforms, we further investigated the potential antimicrobial efficiency of these nano-VOx films and the interactions of human erythrocytes and bacteria (methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa) with our samples in a novel cell–bacteria coculture model. It was demonstrated that these nano-VOx precipitated favorable antibacterial activity on both bacteria, especially on S. aureus, and this effect increased with higher vanadium valence. A possible mechanism accountable for these results might be elevated levels of vanadium-induced intracellular reactive oxygen species. More importantly, based on hemolysis assays, our nano-VOx films were found to be able to kill prokaryotic cells but were not toxic to mammalian cells, holding the potential for the prevention of implant-related hematogenous infections. As far as we know, this is the first report wherein such nano-VOx films have assisted human erythrocytes to combat bacteria in a valence-dependent manner. Additionally, vanadium ions were released from these nano-VOx films in a sustained manner, and low-valence films possessed better biocompatibility with human fibroblasts. This work may provide new insights for biomedical applications of inorganic vanadium compounds and attract growing attention in this field. From the perspective of surface modification and functionalization, this study holds promise to avail the prophylaxis of bloodstream infections involving implantable biomedical devices. PMID:28458535

  14. Development and Applications of Porous Tantalum Trabecular Metal Enhanced Titanium Dental Implants

    PubMed Central

    Bencharit, Sompop; Byrd, Warren C.; Altarawneh, Sandra; Hosseini, Bashir; Leong, Austin; Reside, Glenn; Morelli, Thiago; Offenbacher, Steven

    2013-01-01

    Statement of Problem Porous tantalum trabecular metal has recently been incorporated in titanium dental implants as a new form of implant surface enhancement. However, there is little information on the applications of this material in implant dentistry. Methods We, therefore review the current literature on the basic science and clinical uses of this material. Results Porous tantalum metal is used to improve the contact between osseous structure and dental implants; and therefore presumably facilitate osseointegration. Success of porous tantalum metal in orthopedic implants led to the incorporation of porous tantalum metal in the design of root-from endosseous titanium implants. The porous tantalum three-dimensional enhancement of titanium dental implant surface allows for combining bone ongrowth together with bone ingrowth, or osseoincorporation. While little is known about the biological aspect of the porous tantalum in the oral cavity, there seems to be several possible advantages of this implant design. This article reviews the biological aspects of porous tantalum enhanced titanium dental implants, in particular the effects of anatomical consideration and oral environment to implant designs. Conclusions We propose here possible clinical situations and applications for this type of dental implant. Advantages and disadvantages of the implants as well as needed future clinical studies are discussed. PMID:23527899

  15. Effects of pore size, implantation time and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants

    PubMed Central

    Farrell, Brad J.; Prilutsky, Boris I.; Ritter, Jana M.; Kelley, Sean; Popat, Ketul; Pitkin, Mark

    2013-01-01

    The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40–100 microns and Large, 100–160 microns), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to 7 groups. Implant extrusion rate was measured weekly and skin ingrowth into implants was determined histologically after harvesting implants. It was found that all 3 types of implants demonstrated skin tissue ingrowth of over 30% (at week 3) and 50% (at weeks 4–6) of total implant porous area under the skin; longer implantation resulted in greater skin ingrowth (p<0.05). Only one case of infection was observed (infection rate 2.9%). Small and Nano groups showed the same implant extrusion rate which was lower than the Large group rate (0.06±0.01 vs. 0.16 ± 0.02 cm/week; p<0.05). Ingrowth area was comparable in the Small, Large and Nano implants. However, qualitatively, the Nano implants showed greatest cellular inhabitation within first three weeks. We concluded that percutaneous porous titanium implants allow for skin integration with the potential for a safe seal. PMID:23703928

  16. Electrophoretic-deposited novel ternary silk fibroin/graphene oxide/hydroxyapatite nanocomposite coatings on titanium substrate for orthopedic applications

    NASA Astrophysics Data System (ADS)

    Li, Ming; Xiong, Pan; Mo, Maosong; Cheng, Yan; Zheng, Yufeng

    2016-09-01

    The combination of graphene oxide (GO) with robust mechanical property, silk fibroin (SF) with fascinating biological effects and hydroxyapatite (HA) with superior osteogenic activity is a competitive approach to make novel coatings for orthopedic applications. Herein, the feasibility of depositing ternary SF/GO/HA nanocomposite coatings on Ti substrate was firstly verified by exploiting electrophoretic nanotechnology, with SF being used as both a charging additive and a dispersion agent. The surface morphology, microstructure and composition, in vitro hemocompatibility and in vitro cytocompatibility of the resulting coatings were investigated by SEM, Raman, FTIR spectra and biocompatibility tests. Results demonstrated that GO, HA and SF could be co-deposited with a uniform, smooth thin-film morphology. The hemolysis rate analysis and the platelet adhesion test indicated good blood compatibility of the coatings. The human osteosarcoma MG63 cells displayed well adhesion and proliferation behaviors on the prepared coatings, with enhanced ALP activities. The present study suggested that SF/GO/HA nanocomposite coatings could be a promising candidate for the surface functionalization of biomaterials, especially as orthopedic implant coating.

  17. Artificial intelligence for analyzing orthopedic trauma radiographs.

    PubMed

    Olczak, Jakub; Fahlberg, Niklas; Maki, Atsuto; Razavian, Ali Sharif; Jilert, Anthony; Stark, André; Sköldenberg, Olof; Gordon, Max

    2017-12-01

    Background and purpose - Recent advances in artificial intelligence (deep learning) have shown remarkable performance in classifying non-medical images, and the technology is believed to be the next technological revolution. So far it has never been applied in an orthopedic setting, and in this study we sought to determine the feasibility of using deep learning for skeletal radiographs. Methods - We extracted 256,000 wrist, hand, and ankle radiographs from Danderyd's Hospital and identified 4 classes: fracture, laterality, body part, and exam view. We then selected 5 openly available deep learning networks that were adapted for these images. The most accurate network was benchmarked against a gold standard for fractures. We furthermore compared the network's performance with 2 senior orthopedic surgeons who reviewed images at the same resolution as the network. Results - All networks exhibited an accuracy of at least 90% when identifying laterality, body part, and exam view. The final accuracy for fractures was estimated at 83% for the best performing network. The network performed similarly to senior orthopedic surgeons when presented with images at the same resolution as the network. The 2 reviewer Cohen's kappa under these conditions was 0.76. Interpretation - This study supports the use for orthopedic radiographs of artificial intelligence, which can perform at a human level. While current implementation lacks important features that surgeons require, e.g. risk of dislocation, classifications, measurements, and combining multiple exam views, these problems have technical solutions that are waiting to be implemented for orthopedics.

  18. Can a Silver-Coated Arthrodesis Implant Provide a Viable Alternative to Above Knee Amputation in the Unsalvageable, Infected Total Knee Arthroplasty?

    PubMed

    Wilding, Chris P; Cooper, George A; Freeman, Alexandra K; Parry, Michael C; Jeys, Lee

    2016-11-01

    In the unsalvageable, infected total knee arthroplasty, knee arthrodesis is one treatment option with lower reported reinfection rates compared with repeated 2-stage revision and improved function compared with amputation. One possible method for reducing incidence of recurrent infection treated by arthrodesis is the use of a silver-coated implant. We report our experience of silver-coated arthrodesis nails used for managing infected revision arthroplasty. We primarily assess the rate of reinfection and rate of amputation and report functional outcome measures. Retrospective analysis of all patients undergoing knee arthrodesis with a silver-coated arthrodesis nail between 2008 and 2014. Patient-reported data were recorded prearthrodesis and postarthrodesis (Oxford Knee Score and Short Form-36) as well as evidence of recurrent of infection, subsequent surgery, and the necessity for amputation. Eight patients underwent arthrodesis using the silver-coated arthrodesis nail. Mean duration of follow-up was 16 months (5-35 months). At the point of follow-up, there were no amputations, deaths, or implant revisions. One case of recurrent infection was successfully treated with washout and debridement. The mean prearthrodesis and postarthrodesis Oxford Knee Score difference was +8.9 points (P = .086) with significantly improved pain (P = .019), night pain (P = .021), and ease of standing (P = .003). Arthrodesis of the knee using a silver-coated intramedullary device is successful in eradicating infection and allowing limb conservation. Where infection does recur, this can be successfully treated with implant retention. The use of a silver-coated arthrodesis nail should be considered as an alternative to amputation for patients with a multiply revised and infected total knee arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Prevention, identification, and management of post-operative penile implant complications of infection, hematoma, and device malfunction

    PubMed Central

    O’Rourke, Timothy K.; Erbella, Alexander; Zhang, Yu

    2017-01-01

    Penile prosthesis implant surgery is an effective management approach for a number of urological conditions, including medication refractory erectile dysfunction (ED). Complications encountered post-operatively include infection, bleeding/hematoma, and device malfunction. Since the 1970s, modifications to these devices have reduced complication rates through improvement in antisepsis and design using antibiotic coatings, kink-resistant tubing, lock-out valves to prevent autoinflation, and modified reservoir shapes. Device survival and complication rates have been investigated predominately by retrospective database-derived studies. This review article focuses on the identification and management of post-operative complications following penile prosthetic and implant surgery. Etiology for ED, surgical technique, and prosthesis type are variable among studies. The most common post-operative complications of infection, bleeding, and device malfunction may be minimized by adherence to consistent technique and standard protocol. Novel antibiotic coatings and standard antibiotic regimen may reduce infection rates. Meticulous hemostasis and intraoperative testing of devices may further reduce need for revision surgery. Additional prospective studies with consistent reporting of outcomes and comparison of surgical approach and prosthesis type in patients with variable ED etiology would be beneficial. PMID:29238663

  20. Use of Hardware Battery Drill in Orthopedic Surgery.

    PubMed

    Satish, Bhava R J; Shahdi, Masood; Ramarao, Duddupudi; Ranganadham, Atmakuri V; Kalamegam, Sundaresan

    2017-03-01

    Among the power drills (Electrical/Pneumatic/Battery) used in Orthopedic surgery, battery drill has got several advantages. Surgeons in low resource settings could not routinely use Orthopedic battery drills (OBD) due to the prohibitive cost of good drills or poor quality of other drills. "Hardware" or Engineering battery drill (HBD) is a viable alternative to OBD. HBD is easy to procure, rugged in nature, easy to maintain, durable, easily serviceable and 70 to 75 times cheaper than the standard high end OBD. We consider HBD as one of the cost effective equipment in Orthopedic operation theatres.

  1. PAs in orthopedics in the VHA's community-based outpatient clinics.

    PubMed

    Reed, Daniel O; Hooker, Roderick S

    2017-04-01

    In the Veterans Health Administration (VHA) system, most orthopedic care takes place in the VA medical centers (VAMCs). Because most patients receiving orthopedic care were referred by adult medicine providers, more widely deploying physician assistants (PAs) in orthopedic medicine might help offset this workload. An orthopedic medicine demonstration project recruited, trained, and positioned PAs in community-based outpatient clinics (CBOCs) to improve access to care. The project involved surgeons at the Houston VAMC instructing five newly employed PAs in a wide range of orthopedic evaluation and management strategies before their assignment to a CBOC. An administrative assessment compared encounter data pre- and postproject (2012 and 2014) to determine if this strategy modified orthopedic workload and improved patient access to care. By 2014, orthopedic patient visit volume had increased 31%-10% at the VAMC and 21% at the five CBOCs. Overall, the five deployed PAs managed 28% of all orthopedic encounters spread over 1 year and only 3.2% of visits required VAMC referral for further evaluation or treatment. During the project, the total volume of patient visits increased throughout the Houston VAMC region but access to care for this specialty service also increased, with more veteran musculoskeletal care being met at the five CBOCs, off-loading visit demand centrally. The adaptability and flexibility of new roles has been identified as one of the defining characteristics of PAs. That the VHA can take advantage of this role malleability suggests that employing PAs is useful in meeting medical service needs of veterans.

  2. Biomaterials with Antibacterial and Osteoinductive Properties to Repair Infected Bone Defects

    PubMed Central

    Lu, Haiping; Liu, Yi; Guo, Jing; Wu, Huiling; Wang, Jingxiao; Wu, Gang

    2016-01-01

    The repair of infected bone defects is still challenging in the fields of orthopedics, oral implantology and maxillofacial surgery. In these cases, the self-healing capacity of bone tissue can be significantly compromised by the large size of bone defects and the potential/active bacterial activity. Infected bone defects are conventionally treated by a systemic/local administration of antibiotics to control infection and a subsequent implantation of bone grafts, such as autografts and allografts. However, these treatment options are time-consuming and usually yield less optimal efficacy. To approach these problems, novel biomaterials with both antibacterial and osteoinductive properties have been developed. The antibacterial property can be conferred by antibiotics and other novel antibacterial biomaterials, such as silver nanoparticles. Bone morphogenetic proteins are used to functionalize the biomaterials with a potent osteoinductive property. By manipulating the carrying modes and release kinetics, these biomaterials are optimized to maximize their antibacterial and osteoinductive functions with minimized cytotoxicity. The findings, in the past decade, have shown a very promising application potential of the novel biomaterials with the dual functions in treating infected bone defects. In this review, we will summarize the current knowledge of novel biomaterials with both antibacterial and osteoinductive properties. PMID:26950123

  3. Bundled payments in orthopedic surgery.

    PubMed

    Bushnell, Brandon D

    2015-02-01

    As a result of reading this article, physicians should be able to: 1. Describe the concept of bundled payments and the potential applications of bundled payments in orthopedic surgery. 2. For specific situations, outline a clinical episode of care, determine the participants in a bundling situation, and define care protocols and pathways. 3. Recognize the importance of resource utilization management, quality outcome measurement, and combined economic-clinical value in determining the value of bundled payment arrangements. 4. Identify the implications of bundled payments for practicing orthopedists, as well as the legal issues and potential future directions of this increasingly popular alternative payment method. Bundled payments, the idea of paying a single price for a bundle of goods and services, is a financial concept familiar to most American consumers because examples appear in many industries. The idea of bundled payments has recently gained significant momentum as a financial model with the potential to decrease the significant current costs of health care. Orthopedic surgery as a field of medicine is uniquely positioned for success in an environment of bundled payments. This article reviews the history, logistics, and implications of the bundled payment model relative to orthopedic surgery. Copyright 2015, SLACK Incorporated.

  4. Young Children's Attitudes toward Orthopedic and Sensory Disabilities.

    ERIC Educational Resources Information Center

    DeGrella, Lanier H.; Green, Virginia P.

    1984-01-01

    Attitudes of 64 nondisabled children (three to seven years old) toward orthopedic and sensory disabilities were examined via the Test of Early Attitudes toward Disability. Responses indicated that bias against orthopedic and sensory disabilities increases with age but is not present among three-year-olds. (Author/CL)

  5. Diagnostic imaging in bovine orthopedics.

    PubMed

    Kofler, Johann; Geissbühler, Urs; Steiner, Adrian

    2014-03-01

    Although a radiographic unit is not standard equipment for bovine practitioners in hospital or field situations, ultrasound machines with 7.5-MHz linear transducers have been used in bovine reproduction for many years, and are eminently suitable for evaluation of orthopedic disorders. The goal of this article is to encourage veterinarians to use radiology and ultrasonography for the evaluation of bovine orthopedic disorders. These diagnostic imaging techniques improve the likelihood of a definitive diagnosis in every bovine patient but especially in highly valuable cattle, whose owners demand increasingly more diagnostic and surgical interventions that require high-level specialized techniques. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Surgical simulation training in orthopedics: current insights.

    PubMed

    Kalun, Portia; Wagner, Natalie; Yan, James; Nousiainen, Markku T; Sonnadara, Ranil R

    2018-01-01

    While the knowledge required of residents training in orthopedic surgery continues to increase, various factors, including reductions in work hours, have resulted in decreased clinical learning opportunities. Recent work suggests residents graduate from their training programs without sufficient exposure to key procedures. In response, simulation is increasingly being incorporated into training programs to supplement clinical learning. This paper reviews the literature to explore whether skills learned in simulation-based settings results in improved clinical performance in orthopedic surgery trainees. A scoping review of the literature was conducted to identify papers discussing simulation training in orthopedic surgery. We focused on exploring whether skills learned in simulation transferred effectively to a clinical setting. Experimental studies, systematic reviews, and narrative reviews were included. A total of 15 studies were included, with 11 review papers and four experimental studies. The review articles reported little evidence regarding the transfer of skills from simulation to the clinical setting, strong evidence that simulator models discriminate among different levels of experience, varied outcome measures among studies, and a need to define competent performance in both simulated and clinical settings. Furthermore, while three out of the four experimental studies demonstrated transfer between the simulated and clinical environments, methodological study design issues were identified. Our review identifies weak evidence as to whether skills learned in simulation transfer effectively to clinical practice for orthopedic surgery trainees. Given the increased reliance on simulation, there is an immediate need for comprehensive studies that focus on skill transfer, which will allow simulation to be incorporated effectively into orthopedic surgery training programs.

  7. Artificial intelligence for analyzing orthopedic trauma radiographs

    PubMed Central

    Olczak, Jakub; Fahlberg, Niklas; Maki, Atsuto; Razavian, Ali Sharif; Jilert, Anthony; Stark, André; Sköldenberg, Olof

    2017-01-01

    Background and purpose — Recent advances in artificial intelligence (deep learning) have shown remarkable performance in classifying non-medical images, and the technology is believed to be the next technological revolution. So far it has never been applied in an orthopedic setting, and in this study we sought to determine the feasibility of using deep learning for skeletal radiographs. Methods — We extracted 256,000 wrist, hand, and ankle radiographs from Danderyd’s Hospital and identified 4 classes: fracture, laterality, body part, and exam view. We then selected 5 openly available deep learning networks that were adapted for these images. The most accurate network was benchmarked against a gold standard for fractures. We furthermore compared the network’s performance with 2 senior orthopedic surgeons who reviewed images at the same resolution as the network. Results — All networks exhibited an accuracy of at least 90% when identifying laterality, body part, and exam view. The final accuracy for fractures was estimated at 83% for the best performing network. The network performed similarly to senior orthopedic surgeons when presented with images at the same resolution as the network. The 2 reviewer Cohen’s kappa under these conditions was 0.76. Interpretation — This study supports the use for orthopedic radiographs of artificial intelligence, which can perform at a human level. While current implementation lacks important features that surgeons require, e.g. risk of dislocation, classifications, measurements, and combining multiple exam views, these problems have technical solutions that are waiting to be implemented for orthopedics. PMID:28681679

  8. Synergistic effect of nanotopography and bioactive ions on peri-implant bone response

    PubMed Central

    Su, Yingmin; Komasa, Satoshi; Li, Peiqi; Nishizaki, Mariko; Chen, Luyuan; Terada, Chisato; Yoshimine, Shigeki; Nishizaki, Hiroshi; Okazaki, Joji

    2017-01-01

    Both bioactive ion chemistry and nanoscale surface modifications are beneficial for enhanced osseointegration of endosseous implants. In this study, a facile synthesis approach to the incorporation of bioactive Ca2+ ions into the interlayers of nanoporous structures (Ca-nano) formed on a Ti6Al4V alloy surface was developed by sequential chemical and heat treatments. Samples with a machined surface and an Na+ ion-incorporated nanoporous surface (Na-nano) fabricated by concentrated alkali and heat treatment were used in parallel for comparison. The bone response was investigated by microcomputed tomography assessment, sequential fluorescent labeling analysis, and histological and histomorphometric evaluation after 8 weeks of implantation in rat femurs. No significant differences were found in the nanotopography, surface roughness, or crystalline properties of the Ca-nano and Na-nano surfaces. Bone–implant contact was better in the Ca-nano and Na-nano implants than in the machined implant. The Ca-nano implant was superior to the Na-nano implant in terms of enhancing the volume of new bone formation. The bone formation activity consistently increased for the Ca-nano implant but ceased for the Na-nano implant in the late healing stage. These results suggest that Ca-nano implants have promising potential for application in dentistry and orthopedics. PMID:28184162

  9. Orthopedic injuries from the Andover, Kansas, tornado.

    PubMed

    Rosenfield, A L; McQueen, D A; Lucas, G L

    1994-05-01

    Devastating tornados struck the state of Kansas on Friday, April 26, 1991. Twenty lives were lost and many people were injured. Property damage was extensive. Overall, the outcome of those admitted to the various hospitals was good, with few orthopedic-related complications. The low complication rate can be attributed to thorough open wound management and suspicion and recognition of other potential orthopedic complications such as compartment syndrome.

  10. Increased osteoblast and decreased Staphylococcus epidermidis functions on nanophase ZnO and TiO2.

    PubMed

    Colon, Gabriel; Ward, Brian C; Webster, Thomas J

    2006-09-01

    Many engineers and surgeons trace implant failure to poor osseointegration (or the bonding of an orthopedic implant to juxtaposed bone) and/or bacteria infection. By using novel nanotopographies, researchers have shown that nanostructured ceramics, carbon fibers, polymers, metals, and composites enhance osteoblast adhesion and calcium/phosphate mineral deposition. However, the function of bacteria on materials with nanostructured surfaces remains largely uninvestigated. This is despite the fact that during normal surgical insertion of an orthopedic implant, bacteria from the patient's own skin and/or mucosa enters the wound site. These bacteria (namely, Staphylococcus epidermidis) irreversibly adhere to an implant surface while various physiological stresses induce alterations in the bacterial growth rate leading to biofilm formation. Because of their integral role in determining the success of orthopedic implants, the objective of this in vitro study was to examine the functions of (i) S. epidermidis and (ii) osteoblasts (or bone-forming cells) on ZnO and titania (TiO(2)), which possess nanostructured compared to microstructured surface features. ZnO is a well-known antimicrobial agent and TiO(2) readily forms on titanium once implanted. Results of this study provided the first evidence of decreased S. epidermidis adhesion on ZnO and TiO(2) with nanostructured when compared with microstructured surface features. Moreover, compared with microphase formulations, results of this study showed increased osteoblast adhesion, alkaline phosphatase activity, and calcium mineral deposition on nanophase ZnO and TiO(2). In this manner, this study suggests that nanophase ZnO and TiO(2) may reduce S. epidermidis adhesion and increase osteoblast functions necessary to promote the efficacy of orthopedic implants.

  11. Multifunctional Coatings to Simultaneously Promote Osseointegration and Prevent Infection of Orthopaedic Implants

    PubMed Central

    Raphel, Jordan; Holodniy, Mark; Goodman, Stuart B.; Heilshorn, Sarah C.

    2016-01-01

    The two leading causes of failure for joint arthroplasty prostheses are aseptic loosening and periprosthetic joint infection. With the number of primary and revision joint replacement surgeries on the rise, strategies to mitigate these failure modes have become increasingly important. Much of the recent work in this field has focused on the design of coatings either to prevent infection while ignoring bone mineralization or vice versa, to promote osseointegration while ignoring microbial susceptibility. However, both coating functions are required to achieve long-term success of the implant; therefore, these two modalities must be evaluated in parallel during the development of new orthopaedic coating strategies. In this review, we discuss recent progress and future directions for the design of multifunctional orthopaedic coatings that can inhibit microbial cells while still promoting osseointegration. PMID:26851394

  12. Orthopedic Surgery Resident Debt Load and Its Effect on Career Choice.

    PubMed

    Johnson, Joey P; Cassidy, Dale B; Tofte, Josef N; Bariteau, Jason T; Daniels, Alan H

    2016-05-01

    Student loan debt has become a topic of discussion and debate among physicians and legislators. This study seeks to assess the level of debt of orthopedic surgery residents and to determine whether debt burden affects the career choice of orthopedic trainees. A 26-question, anonymous survey was distributed via email to resident trainees enrolled in different medical and surgical specialty training programs across the United States. Orthopedic trainees were compared with trainees in other specialties using comparative statistics. Of the approximately 13,503 residents who were sent the survey, a total of 3076 responded, including 167 of an estimated 580 orthopedic residents, for approximate response rates of 22.8% and 28.8%, respectively. On average, orthopedic surgery residents were at a later post-graduate year than overall respondents (P<.025). When asked if student loan debt would influence the next step in their career, nonorthopedic residents were statistically more likely to respond "yes" compared with orthopedic surgery residents (57.21% vs 49.08%, respectively; P=.041). More than 50% of all respondents agreed that student loan debt would affect their type or location of practice. The majority of orthopedic residents take student loan debt into consideration when determining their final location and type of practice, although less so for orthopedic trainees compared with other specialties. As medical education continues to become more expensive and the threat of dropping physician reimbursement looms on the horizon, student debt may become a primary driving factor for young American physicians' career plans. [Orthopedics. 2016; 39(3):e438-e443.]. Copyright 2016, SLACK Incorporated.

  13. Surveillance, Auditing, and Feedback Can Reduce Surgical Site Infection Dramatically: Toward Zero Surgical Site Infection.

    PubMed

    Manivannan, Bhavani; Gowda, Deepak; Bulagonda, Pradeep; Rao, Abhishek; Raman, Sai Suguna; Natarajan, Shanmuga Vadivoo

    2018-04-01

    We evaluated the Surveillance of Surgical Site Infection (SSI), Auditing, and Feedback (SAF) effect on the rate of compliance with an SSI care bundle and measured its effectiveness in reducing the SSI rate. A prospective cohort study from January 2014 to December 2016 was classified into three phases: pre-SAF, early-SAF, and late-SAF. Pre-operative baseline characteristics of 24,677 patients who underwent orthopedic, cardiovascular thoracic surgery (CTVS) or urologic operations were recorded. Univariable analyses of the SSI rates in the pre-SAF and post-SAF phases were performed. Percentage compliance and non-compliance with each care component were calculated. Correlation between reduction in the SSI rate and increase in compliance with the pre-operative, peri-operative, and post-operative care-bundle components was performed using the Spearman test. There was a significant decrease in the SSI rate in orthopedic procedures that involved surgical implantation and in mitral valve/aortic valve (MVR/AVR) cardiac operations, with a relative risk (RR) ratio of 0.19 (95% confidence interval [CI] 0.12-0.31) and 0.08 (95% CI 0.03-0.22), respectively. The SSI rate was inversely correlated with the rate of compliance with pre-operative (r = -0.738; p = 0.037), peri-operative (r = - 0.802; p = 0.017), and post-operative (r = -0.762; p = 0.028) care bundles. Implementation of the Surveillance of SSI, Auditing, and Feedback bundle had a profound beneficial effect on the SSI rate, thereby reducing healthcare costs and improving patient quality of life.

  14. Negative pressure wound therapy for the treatment of infected wounds with exposed knee joint after patellar fracture.

    PubMed

    Lee, Sang Yang; Niikura, Takahiro; Miwa, Masahiko; Sakai, Yoshitada; Oe, Keisuke; Fukazawa, Takahiro; Kawakami, Yohei; Kurosaka, Masahiro

    2011-06-14

    Treatment of soft tissue defects with exposed bones and joints, resulting from trauma, infection, and surgical complications, represents a major challenge. The introduction of negative pressure wound therapy has changed many wound management practices. Negative pressure wound therapy has recently been used in the orthopedic field for management of traumatic or open wounds with exposed bone, nerve, tendon, and orthopedic implants. This article describes a case of a patient with a large soft tissue defect and exposed knee joint, in which negative pressure wound therapy markedly improved wound healing. A 50-year-old man presented with an ulceration of his left knee with exposed joint, caused by severe wound infections after open reduction and internal fixation of a patellar fracture. After 20 days of negative pressure wound therapy, a granulated wound bed covered the exposed bones and joint.To our knowledge, this is the first report of negative pressure wound therapy used in a patient with a large soft tissue defect with exposed knee joint. Despite the chronic wound secondary to infection, healing was achieved through the use of the negative pressure wound therapy, thus promoting granulation tissue formation and closing the joint. We suggest negative pressure wound therapy as an alternative option for patients with lower limb wounds containing exposed bones and joints when free flap transfer is contraindicated. Our result added to the growing evidence that negative pressure wound therapy is a useful adjunctive treatment for open wounds around the knee joint. Copyright 2011, SLACK Incorporated.

  15. Characteristics and trends of orthopedic publications between 2000 and 2009.

    PubMed

    Lee, Kyoung Min; Ryu, Mi Sun; Chung, Chin Youb; Choi, In Ho; Kwon, Dae Gyu; Kim, Tae Won; Sung, Ki Hyuk; Seo, Sang Gyo; Park, Moon Seok

    2011-09-01

    This study was undertaken to investigate the trends of orthopedic publications during the last decade, and to document the country of origin, journal, funding source, and language of contribution using PubMed. Orthopedic articles published between 2000 and 2009 were retrieved from PubMed using the following search terms: "orthopaedic[Affiliation] AND ("2000/1/1"[PDAT]: "2009/12/31"[PDAT])" and "orthopedic[Affiliation] AND ("2000/1/1"[PDAT]: "2009/12/31"[PDAT])." The articles were downloaded in XML file format, which contained the following information: article title, author names, journal names, publication dates, article types, languages, authors' affiliations and funding sources. These information was extracted, sorted, and rearranged using the database's management software. We investigated the annual number of published orthopedic articles worldwide and the annual rate of increase. Furthermore, the country of publication origin, journal, funding source, and language of contribution were also investigated. A total of 46,322 orthopedic articles were published and registered in PubMed in the last 10 years. The worldwide number of published orthopedic articles increased from 2,889 in 2000 to 6,909 in 2009, showing an annual increase of 384.6 articles, or an annualized compound rate of 10.2%. The United States ranked highest in the number of published orthopedic articles, followed by Japan, the United Kingdom, Germany, and the Republic of Korea. Among the orthopedic articles published worldwide during the last 10 years, 37.9% pertained studies performed in the United States. Fifty-seven point three percent (57.3%) of articles were published in journals established in the United States. Among the published orthopaedic articles, 4,747 articles (10.2%) disclosed financial support by research funds, of which 4,688 (98.8%) articles utilized research funds from the United States. Most articles were published in English (97.2%, 45,030 articles). The number of published

  16. Characteristics and Trends of Orthopedic Publications between 2000 and 2009

    PubMed Central

    Lee, Kyoung Min; Ryu, Mi Sun; Chung, Chin Youb; Choi, In Ho; Kwon, Dae Gyu; Kim, Tae Won; Sung, Ki Hyuk; Seo, Sang Gyo

    2011-01-01

    Background This study was undertaken to investigate the trends of orthopedic publications during the last decade, and to document the country of origin, journal, funding source, and language of contribution using PubMed. Methods Orthopedic articles published between 2000 and 2009 were retrieved from PubMed using the following search terms: "orthopaedic[Affiliation] AND ("2000/1/1"[PDAT]: "2009/12/31"[PDAT])" and "orthopedic[Affiliation] AND ("2000/1/1"[PDAT]: "2009/12/31"[PDAT])." The articles were downloaded in XML file format, which contained the following information: article title, author names, journal names, publication dates, article types, languages, authors' affiliations and funding sources. These information was extracted, sorted, and rearranged using the database's management software. We investigated the annual number of published orthopedic articles worldwide and the annual rate of increase. Furthermore, the country of publication origin, journal, funding source, and language of contribution were also investigated. Results A total of 46,322 orthopedic articles were published and registered in PubMed in the last 10 years. The worldwide number of published orthopedic articles increased from 2,889 in 2000 to 6,909 in 2009, showing an annual increase of 384.6 articles, or an annualized compound rate of 10.2%. The United States ranked highest in the number of published orthopedic articles, followed by Japan, the United Kingdom, Germany, and the Republic of Korea. Among the orthopedic articles published worldwide during the last 10 years, 37.9% pertained studies performed in the United States. Fifty-seven point three percent (57.3%) of articles were published in journals established in the United States. Among the published orthopaedic articles, 4,747 articles (10.2%) disclosed financial support by research funds, of which 4,688 (98.8%) articles utilized research funds from the United States. Most articles were published in English (97.2%, 45,030 articles

  17. The degree of peri-implant osteolysis induced by PEEK, CoCrMo, and HXLPE wear particles: a study based on a porous Ti6Al4V implant in a rabbit model.

    PubMed

    Du, Zhe; Zhu, Zhonglin; Wang, You

    2018-01-31

    Polyether-ether-ketone (PEEK), cobalt-chromium-molybdenum (CoCrMo), and highly cross-linked polyethylene (HXLPE) are biomaterials used in orthopedic implants; their wear particles are considered to induce peri-implant osteolysis. We examined whether different particle types induce the same degree of peri-implant osteolysis. Forty female rabbits were randomly divided into four groups-the control group (n = 10), which received implantation operation and sham operation at 1 month postoperation; three experimental groups (n = 10 in each group), which received implantation operation along with administration of 0.1 mL of particle suspension (approximately 1.0 × 10 8 PEEK, CoCrMo, or HXLPE wear particles) into the knee joint at 1 month postoperation. All rabbits were sacrificed at 2 months postoperation. The synovium was removed and histologically assessed. The distal femurs with the implants were analyzed via micro-computed tomography (CT) and hard tissue biopsy. The average size of almost 90% of the particles was < 5 μm, indicating no significant difference in the three particle types. IL-1β, IL-8, TNFα, RANKL, and MCP-1 expression in PEEK and CoCrMo groups was high, while that in the HXLPE group was low. The bone density (BD) and bone volume/total volume (BV/TV) of the porous structures (part of the implants in all groups) in experimental groups did not decrease markedly (p > 0.05), while BD in the peripheral regions in experimental groups decreased markedly compared to control groups (p < 0.05). BV/TV in the peripheral regions was significantly decreased in PEEK and CoCrMo groups when compared to control group (p < 0.05), while no significant difference was noted between HXLPE and control groups (p > 0.05). The changes in BV observed in the hard tissue sections were consistent with those noted in the micro-CT findings. PEEK, CoCrMo, and HXLPE wear particles (approximately having the same size and doses) induce peri-implant

  18. Emotional intelligence in orthopedic surgery residents.

    PubMed

    Chan, Kevin; Petrisor, Brad; Bhandari, Mohit

    2014-04-01

    Emotional intelligence (EI) is the ability to understand and manage emotions in oneself and others. It was originally popularized in the business literature as a key attribute for success that was distinct from cognitive intelligence. Increasing focus is being placed on EI in medicine to improve clinical and academic performance. Despite the proposed benefits, to our knowledge, there have been no previous studies on the role of EI in orthopedic surgery. We evaluated baseline data on EI in a cohort of orthopedic surgery residents. We asked all orthopedic surgery residents at a single institution to complete an electronic version of the Mayer-Salovey-Caruso Emotional Intelligence Test (MSCEIT). We used completed questionnaires to calculate total EI scores and 4 branch scores. Data were analyzed according to a priori cutoff values to determine the proportion of residents who were considered competent on the test. Data were also analyzed for possible associations with age, sex, race and level of training. Thirty-nine residents (100%) completed the MSCEIT. The mean total EI score was 86 (maximum score 145). Only 4 (10%) respondents demonstrated competence in EI. Junior residents (p = 0.026), Caucasian residents (p = 0.009) and those younger than 30 years (p = 0.008) had significantly higher EI scores. Our findings suggest that orthopedic residents score low on EI based on the MSCEIT. Optimizing resident competency in noncognitive skills may be enhanced by dedicated EI education, training and testing.

  19. Osteoblast adhesion on novel machinable calcium phosphate/lanthanum phosphate composites for orthopedic applications.

    PubMed

    Ergun, Celaletdin; Liu, Huinan; Webster, Thomas J

    2009-06-01

    Lanthanum phosphate (LaPO(4), LP) was combined with either hydroxyapatite (HA) or tricalcium phosphate (TCP) to form novel composites for orthopedic applications. In this study, these composites were prepared by wet chemistry synthesis and subsequent powder mixing. These HA/LP and TCP/LP composites were characterized in terms of phase stability and microstructure evolution during sintering using X-ray diffraction (XRD) and scanning electron microscopy (SEM). Their machinability was evaluated using a direct drilling test. For HA/LP composites, LP reacted with HA during sintering and formed a new phase, Ca(8)La(2)(PO(4))(6)O(2), as a reaction by-product. However, TCP/LP composites showed phase stability and the formation of a weak interface between TCP and LP machinability when sintered at 1100 degrees C, which is crucial for achieving desirable properties. Thus, these novel TCP/LP composites fulfilled the requirements for machinability, a key consideration for manufacturing orthopedic implants. Moreover, the biocompatibility of these novel LP composites was studied, for the first time, in this paper. In vitro cell culture tests demonstrated that the LP and its composites supported osteoblast (bone-forming cell) adhesion similar to natural bioceramics (such as HA and TCP). In conclusion, these novel LP composites should be further studied and developed for more effectively treating bone related diseases or injuries. 2008 Wiley Periodicals, Inc.

  20. Factors affecting interest in orthopedics among female medical students: a prospective analysis.

    PubMed

    Baldwin, Keith; Namdari, Surena; Bowers, Andrea; Keenan, Mary Ann; Levin, L Scott; Ahn, Jaimo

    2011-12-06

    The field of orthopedics has a limited ability to recruit high-quality female applicants. The purpose of this study was to determine whether early exposure to the field affects a woman's decision to pursue orthopedics. We performed a prospective, nonrandomized cohort study between academic years 2005 and 2009 and compared interest in orthopedic surgery among female (n=271) and male (n=71) medical students at 2 urban teaching institutions. Elective lectures and orthopedic literature were distributed via e-mail to the study participants. These materials included articles published in the medical literature, materials produced and distributed by the American Academy of Orthopaedic Surgeons, and Web sites providing educational materials. The primary outcome was the likelihood of application for orthopedic residency. We studied the influence of demographics, exposure, and attitudes on interest in pursuing an orthopedic career. Men had a significantly higher baseline level of interest in orthopedic surgery than women (P=.005). Younger age (P<.001) and personal (P<.001), independent (P<.001), and school (P=.023) exposures to orthopedics were significantly related to interest among women. At final follow-up, total personal exposures (P=.003) and total independent exposures (P<.001) in the form of our literature and lectures were correlated with final interest in women. Female interest was decreased by the long hours, physical demands, and predominantly male nature of the field. Early exposure to orthopedic educational resources may be useful in generating female interest. Perceptions and attitudes regarding orthopedic surgery must to be changed to attract the best and brightest minds, regardless of sex. Copyright © 2011, SLACK Incorporated.

  1. The use of computer-assisted orthopedic surgery for total knee replacement in daily practice: a survey among ESSKA/SGO-SSO members.

    PubMed

    Friederich, N; Verdonk, R

    2008-06-01

    Computer-assisted orthopedic surgery (CAOS) for total knee arthroplasty is an emerging surgical tool, yet little is known about how it is being used in everyday orthopedic centers. We sought to better understand physicians' current practices and beliefs on this topic through performing a Web-based survey. Between December 2006 and January 2007, a 24-question survey was emailed to 3,330 members of the European Society of Sports Traumatology Knee Surgery and Arthroscopy (ESSKA) and the Swiss Orthopedic Society (SGO-SSO), with 389 (11.7%) agreeing to participate. Of this group, 202 (51.9%) reported that their center was equipped with a navigation system, which was an image-free based system for most (83.2%) and was primarily used for total knee arthroplasty (61.4%). In terms of the proportion of use, 50.5% of respondents used their navigation system in less than 25% of cases, 16.3% in 25-50% of cases, 7.4% in 51-75% of cases, and 25.7% in more than 75% of cases. The potential for improving the alignment of prosthesis was the most strongly cited reason for using a navigation system, while the potential for increasing operation times and the risk of infections were the most strongly cited reasons for not using a navigation system. Approximately half of respondents surveyed believed navigation systems were a real innovation contributing to the improvement of total knee implantation. However, heavy usage of computer-assisted navigation (> or =51% of cases) was observed in only 33.1% of respondents, with only a quarter using it at rates that could be considered frequent (>75% of cases). Forty-eight percent of respondents said they will use a navigation system in more cases and 39.1% that their usage will stay the same. These findings indicate that CAOS is being used only moderately in current practices, though respondents generally had a positive opinion of its potential benefits. Physicians may be awaiting more data before adopting the use of these systems, though survey

  2. Online ratings of orthopedic surgeons: analysis of 2185 reviews.

    PubMed

    Bakhsh, Wajeeh; Mesfin, Addisu

    2014-08-01

    Online ratings of orthopedic surgeons have not been studied. We conducted a study to evaluate the online ratings of orthopedic surgeons in a major metropolitan region, to identify trends in ratings of orthopedic surgeons, and to analyze ratings to identify variables of significance in determining overall rating. Website traffic was used to identify the 8 busiest physician rating websites: AngiesList.com, EverydayHealth.com, Thirdage.com, Yelp.com, HealthGrades.com, Vitals.com, UCompareHealthcare.com, and RateMDs.com. These websites were consulted for data regarding orthopedic surgeons in a major metropolitan region with a population of 1.3 million in September 2012. Surgeon ratings were scaled from 0 to 100 for homogeneity. Of the 8 websites considered, 4 were excluded because of inaccessible or unreliable data. The qualifying sites were HealthGrades.com, Vitals.com, UCompareHealthcare.com, and RateMDs.com, with 2185 reviews total. Across these websites, mean overall rating of orthopedic surgeons was 81.8 (between 100, definitely recommend, and 80, mostly recommend). Five variables were statistically significant (Ps < .01) for higher ratings: ease of scheduling, time spent with patient, wait time, surgeon proficiency/knowledge, and bedside manner.

  3. Cutaneous and systemic hypersensitivity reactions to metallic implants.

    PubMed

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure. However, other metal ions as well as bone cement components can cause such hypersensitivity reactions. To complicate things, patients may also develop delayed-type hypersensitivity reactions to metals (ie, in-stent restenosis, prosthesis loosening, inflammation, pain, or allergic contact dermatitis) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions remains to be fully understood. This review provides an update of the current knowledge in this field and should be valuable to health care providers who manage patients with conditions related to this field.

  4. Thrush and Other Candida Infections

    MedlinePlus

    ... Life Family Life Family Life Medical Home Family Dynamics Media Work & Play Getting Involved in Your Community ... and Urinary Tract Glands & Growth Head Neck & Nervous System Heart Infections Learning Disabilities Obesity Orthopedic Prevention Sexually ...

  5. The Effect of Ag and Ag+N Ion Implantation on Cell Attachment Properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Urkac, Emel Sokullu; Oztarhan, Ahmet; Gurhan, Ismet Deliloglu

    2009-03-10

    Implanted biomedical prosthetic devices are intended to perform safely, reliably and effectively in the human body thus the materials used for orthopedic devices should have good biocompatibility. Ultra High Molecular Weight Poly Ethylene (UHMWPE) has been commonly used for total hip joint replacement because of its very good properties. In this work, UHMWPE samples were Ag and Ag+N ion implanted by using the Metal-Vapor Vacuum Arc (MEVVA) ion implantation technique. Samples were implanted with a fluency of 1017 ion/cm2 and extraction voltage of 30 kV. Rutherford Backscattering Spectrometry (RBS) was used for surface studies. RBS showed the presence of Agmore » and N on the surface. Cell attachment properties investigated with model cell lines (L929 mouse fibroblasts) to demonstrate that the effect of Ag and Ag+N ion implantation can favorably influence the surface of UHMWPE for biomedical applications. Scanning electron microscopy (SEM) was used to demonstrate the cell attachment on the surface. Study has shown that Ag+N ion implantation represents more effective cell attachment properties on the UHMWPE surfaces.« less

  6. Awareness campaign. Orthopedic Hospital of Oklahoma launches awareness campaign.

    PubMed

    2007-01-01

    The Orthopedic Hospital of Oklahoma is a 25-bed inpatient and outpatient center with one focus: Orthopedics. To acquaint people with its services and build brand awareness to drive market share, the hospital launched a print campaign featuring actual patients.

  7. A new rabbit model of implant-related biofilm infection: development and evaluation

    NASA Astrophysics Data System (ADS)

    Chu, Cheng-Bing; Zeng, Hong; Shen, Ding-Xia; Wang, Hui; Wang, Ji-Fang; Cui, Fu-Zhai

    2016-03-01

    This study is to establish a rabbit model for human prosthetic joint infection and biofilm formation. Thirty-two healthy adult rabbits were randomly divided into four groups and implanted with stainless steel screws and ultra-high molecular weight polyethylene (UHMWPE) washers in the non-articular surface of the femoral lateral condyle of the right hind knees. The rabbit knee joints were inoculated with 1 mL saline containing 0, 102, 103, 104 CFU of Staphylococcus epidermidis ( S. epidermidis) isolated from the patient with total knee arthroplasty (TKA) infection, respectively. On the 14th postoperative day, the UHMWPE washers from the optimal 103 CFU group were further examined. The SEM examination showed a typical biofilm construction that circular S. epidermidis were embedded in a mucous-like matrix. In addition, the LCSM examination showed that the biofilm consisted of the polysaccharide stained bright green fluorescence and S. epidermidis radiating red fluorescence. Thus, we successfully create a rabbit model for prosthetic joint infection and biofilm formation, which should be valuable for biofilm studies.

  8. Nanotubular surface modification of metallic implants via electrochemical anodization technique.

    PubMed

    Wang, Lu-Ning; Jin, Ming; Zheng, Yudong; Guan, Yueping; Lu, Xin; Luo, Jing-Li

    2014-01-01

    Due to increased awareness and interest in the biomedical implant field as a result of an aging population, research in the field of implantable devices has grown rapidly in the last few decades. Among the biomedical implants, metallic implant materials have been widely used to replace disordered bony tissues in orthopedic and orthodontic surgeries. The clinical success of implants is closely related to their early osseointegration (ie, the direct structural and functional connection between living bone and the surface of a load-bearing artificial implant), which relies heavily on the surface condition of the implant. Electrochemical techniques for modifying biomedical implants are relatively simple, cost-effective, and appropriate for implants with complex shapes. Recently, metal oxide nanotubular arrays via electrochemical anodization have become an attractive technique to build up on metallic implants to enhance the biocompatibility and bioactivity. This article will thoroughly review the relevance of electrochemical anodization techniques for the modification of metallic implant surfaces in nanoscale, and cover the electrochemical anodization techniques used in the development of the types of nanotubular/nanoporous modification achievable via electrochemical approaches, which hold tremendous potential for bio-implant applications. In vitro and in vivo studies using metallic oxide nanotubes are also presented, revealing the potential of nanotubes in biomedical applications. Finally, an outlook of future growth of research in metallic oxide nanotubular arrays is provided. This article will therefore provide researchers with an in-depth understanding of electrochemical anodization modification and provide guidance regarding the design and tuning of new materials to achieve a desired performance and reliable biocompatibility.

  9. Nanotubular surface modification of metallic implants via electrochemical anodization technique

    PubMed Central

    Wang, Lu-Ning; Jin, Ming; Zheng, Yudong; Guan, Yueping; Lu, Xin; Luo, Jing-Li

    2014-01-01

    Due to increased awareness and interest in the biomedical implant field as a result of an aging population, research in the field of implantable devices has grown rapidly in the last few decades. Among the biomedical implants, metallic implant materials have been widely used to replace disordered bony tissues in orthopedic and orthodontic surgeries. The clinical success of implants is closely related to their early osseointegration (ie, the direct structural and functional connection between living bone and the surface of a load-bearing artificial implant), which relies heavily on the surface condition of the implant. Electrochemical techniques for modifying biomedical implants are relatively simple, cost-effective, and appropriate for implants with complex shapes. Recently, metal oxide nanotubular arrays via electrochemical anodization have become an attractive technique to build up on metallic implants to enhance the biocompatibility and bioactivity. This article will thoroughly review the relevance of electrochemical anodization techniques for the modification of metallic implant surfaces in nanoscale, and cover the electrochemical anodization techniques used in the development of the types of nanotubular/nanoporous modification achievable via electrochemical approaches, which hold tremendous potential for bio-implant applications. In vitro and in vivo studies using metallic oxide nanotubes are also presented, revealing the potential of nanotubes in biomedical applications. Finally, an outlook of future growth of research in metallic oxide nanotubular arrays is provided. This article will therefore provide researchers with an in-depth understanding of electrochemical anodization modification and provide guidance regarding the design and tuning of new materials to achieve a desired performance and reliable biocompatibility. PMID:25258532

  10. A new method for shape and texture classification of orthopedic wear nanoparticles.

    PubMed

    Zhang, Dongning; Page, Janet R; Kavanaugh, Aaron E; Billi, Fabrizio

    2012-09-27

    Detailed morphologic analysis of particles produced during wear of orthopedic implants is important in determining a correlation among material, wear, and biological effects. However, the use of simple shape descriptors is insufficient to categorize the data and to compare the nature of wear particles generated by different implants. An approach based on Discrete Fourier Transform (DFT) is presented for describing particle shape and surface texture. Four metal-on-metal bearing couples were tested in an orbital wear simulator under standard and adverse (steep-angled cups) wear simulator conditions. Digitized Scanning Electron Microscope (SEM) images of the wear particles were imported into MATLAB to carry out Fourier descriptor calculations via a specifically developed algorithm. The descriptors were then used for studying particle characteristics (shape and texture) as well as for cluster classification. Analysis of the particles demonstrated the validity of the proposed model by showing that steep-angle Co-Cr wear particles were more asymmetric, compressed, extended, triangular, square, and roughened at 3 Mc than after 0.25 Mc. In contrast, particles from standard angle samples were only more compressed and extended after 3 Mc compared to 0.25 Mc. Cluster analysis revealed that the 0.25 Mc steep-angle particle distribution was a subset of the 3 Mc distribution.

  11. Evaluating Device Design and Cleanability of Orthopedic Device Models Contaminated with a Clinically Relevant Bone Test Soil.

    PubMed

    Lucas, Anne D; Nagaraja, Srinidhi; Gordon, Edward A; Hitchins, Victoria M

    2015-01-01

    Reusable medical devices need to be cleaned prior to disinfection or sterilization and subsequent use to prevent infections. The cleanability of medical devices depends in part on the design of the device. This study examined how models of orthopedic medical devices of increasing complexity retain calcium phosphate bone cement, a relevant test soil for these devices. The dye Alizarin Red S and micro-computed tomography (μCT) were used to assess the amount and location of bone cement debris in a series of model orthopedic devices. Testing was performed after soiling and cleaning once, and soiling and cleaning 10 times. The color change of the dye after reacting with the bone cement was useful for indicating the presence of bone cement in these models. High-resolution μCT analysis provided the volume and location of the bone cement. Models that were more complex retained significantly more bone debris than simpler designs. Model devices repeatedly soiled and cleaned 10 times retained significantly more bone debris than those soiled and cleaned once. Significantly more bone cement was retained in the more complex lumen structures. This information may be useful in designing reusable orthopedic devices, and other complex medical devices with lumens.

  12. Decontamination of dental implant surface in peri-implantitis treatment: A literature review

    PubMed Central

    Buitrago-Vera, Pedro; Solá-Ruiz, María F.; Ferrer-García, Juan C.

    2013-01-01

    Etiological treatment of peri-implantitis aims to reduce the bacterial load within the peri-implant pocket and decontaminate the implant surface in order to promote osseointegration. The aim of this literature review was to evaluate the efficacy of different methods of implant surface decontamination. A search was conducted using the PubMed (Medline) database, which identified 36 articles including in vivo and in vitro studies, and reviews of different decontamination systems (chemical, mechanical, laser and photodynamic therapies). There is sufficient consensus that, for the treatment of peri-implant infections, the mechanical removal of biofilm from the implant surface should be supplemented by chemical decontamination with surgical access. However, more long-term research is needed to confirm this and to establish treatment protocols responding to different implant characterics. Key words:Peri-implantitis, treatment, decontamination, implant surface, laser. PMID:23986023

  13. In situ plasma fabrication of ceramic-like structure on polymeric implant with enhanced surface hardness, cytocompatibility and antibacterial capability.

    PubMed

    Liu, Jun; Zhang, Wei; Shi, Haigang; Yang, Kun; Wang, Gexia; Wang, Pingli; Ji, Junhui; Chu, Paul K

    2016-05-01

    Polymeric materials are commonly found in orthopedic implants due to their unique mechanical properties and biocompatibility but the poor surface hardness and bacterial infection hamper many biomedical applications. In this study, a ceramic-like surface structure doped with silver is produced by successive plasma implantation of silicon (Si) and silver (Ag) into the polyamine 66 (PA66) substrate. Not only the surface hardness and elastic modulus are greatly enhanced due to the partial surface carbonization and the ceramic-like structure produced by the reaction between energetic Si and the carbon chain of PA66, but also the antibacterial activity is improved because of the combined effects rendered by Ag and SiC structure. Furthermore, the modified materials which exhibit good cytocompatibility upregulate bone-related genes and proteins expressions of the contacted bone mesenchymal stem cells (BMSCs). For the first time, it explores out that BMSCs osteogenesis on the antibacterial ceramic-like structure is mediated via the iNOS and nNOS signal pathways. The results reveal that in situ plasma fabrication of an antibacterial ceramic-like structure can endow PA66 with excellent surface hardness, cytocompatibility, as well as antibacterial capability. © 2016 Wiley Periodicals, Inc.

  14. Investigation of Wear and Corrosion of a High-Carbon Stellite Alloy for Hip Implants

    NASA Astrophysics Data System (ADS)

    Hu, P. S.; Liu, R.; Liu, J.; McRae, G.

    2014-04-01

    Low-carbon Stellite 21 has been used as hip implant material for a number of decades; however, its limited metal-on-metal bearing has resulted in loosening between the femoral head and the acetabular cup of hip implants. In order to improve the metal-on-metal bearing, it is proposed that a high-carbon alloy, Stellite 720, surface coating be applied on Stellite 21 hip implants to improve mechanical and tribological performance. For this coating to be practical, it must also meet the requirements of corrosion resistance for orthopedic implant materials. In this research, Stellite 720 is investigated with pin-on-disk wear tests, and electrochemical and immersion corrosion tests in simulated human body fluid (Hank's solution; pH 7.4 at temperature of 37°C). The experimental results demonstrate that Stellite 720 exhibits much better wear resistance than Stellite 21, and has the potential for better corrosion resistance as well. The applicability of coating Stellite 21 hip implants with Stellite 720 is discussed.

  15. Orthopedic Surgeons' Management of Elective Surgery for Patients Who Use Nicotine.

    PubMed

    Lilley, Matthew; Krosin, Michael; Lynch, Tennyson L; Leasure, Jeremi

    2017-01-01

    Despite significant research documenting the detrimental effects of tobacco, the orthopedic literature lacks evidence regarding how surgeons alter their management of elective surgery when patients use nicotine. To better understand how patients' use of nicotine influences orthopedic surgeons' pre- and postoperative management of elective surgery, a 9-question paper survey was distributed at the 2012 annual meeting of the American Academy of Orthopaedic Surgeons among attending US orthopedic surgeons, including general orthopedists and specialty-trained orthopedic surgeons. Survey questions focused on attitudes and practice management regarding patients who use nicotine. Using a chi-square test, no statistically significant variation was observed between subspecialists and general orthopedists or among different subspecialties. Ninety-eight percent of the orthopedic surgeons surveyed counseled tobacco users about the adverse effects of nicotine. However, approximately half of all of the respondents spent less than 5 minutes on perioperative nicotine counseling. Forty-one percent of all of the respondents never delayed elective surgery because of a patient's nicotine use, followed closely by 39% delaying surgery for less than 3 months. Subspecialty had little influence on how orthopedic surgeons managed nicotine users. The high rate of counseling on the adverse effects of nicotine suggested agreement regarding the detrimental effects of smoking. However, the study population infrequently delayed surgery or used smoking cessation measures. Studies are needed to determine why few surgeons frequently alter the management of nicotine users and what modifications in orthopedic practice could improve outcomes for these patients. [Orthopedics. 2017; 40(1):e90-e94.]. Copyright 2016, SLACK Incorporated.

  16. [Subcutaneous implantation type central venous port management in patients with malignant tumors effect of different antiseptic agents on central venous port-related infection].

    PubMed

    Sato, Junya; Kumagai, Masumi; Kato, Kenichi; Akahane, Akio; Suzuki, Michiko; Kashiwaba, Masahiro; Sone, Miyuki; Kudo, Kenzo

    2014-08-01

    Subcutaneous implantation type central venous ports(CV ports)are used in chemotherapy. Here, we prospectively examined the frequency of CV port-related infections when the disinfectant was changed from 10% povidone iodine to 1% chlorhexidine ethanol or 70% ethanol. The subjects were patients with malignant tumors, who had newly been implanted with CV ports. We examined CV port-related infections at 1 week after CV port implantation and every 2 weeks thereafter, following sterilization upon insertion of a Huber needle to the CV port. CV port evulsion due to CV port-related infection was noted in 3 patients(4.8%)in whom 15%chlorhexidine ethanol was used(n=62)and in 2 patients(3.3%)in whom 70% ethanol was used(n=60). Infection rates per 1,000 days of CV port use were 1.48% and 1.01%, respectively. Thus, the outcomes of sterilization using 1% chlorhexidine ethanol and 70% ethanol did not differ significantly from those on using 10% povidone iodine for sterilization, based on preliminary results at our institution(3 of 59 patients[5.1%]had port evulsion due to CV port-related infection and the infection rate per 1,000 days of CV port use was 1.47%, Akahane et al, 2012). Chlorhexidine ethanol and ethanol are very convenient to use because they dry quickly and do not need discoloration. Accordingly, chlorhexidine ethanol and ethanol might be useful in CV port management.

  17. Dislocation and spontaneous reduction of the femoral implant against the femoral neck in an infected metal on metal hip resurfacing with complex collection.

    PubMed

    Tins, Bernhard

    2011-07-01

    Metal on metal resurfacing hip implants are known to have complications unique to this type of implant. The case presented adds a further previously not described complication, the dislocation and spontaneous reduction of the pin of the femoral component against the femoral neck. The radiographic and CT findings are demonstrated. The dislocation was aided by bone loss due to an infection with a large periarticular collection. Periarticular collections in hip resurfacings are often due to a hypersensitivity type reaction to metal debris. However in the case presented it was due to infection. MRI was not able to discern the infection from a sterile collection. CT demonstrated bone loss and periosteal reaction suggestive of infection. In addition calcification of the pseudocapsule was seen, this is not a recognized feature of sterile collections. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Safety in the operating room during orthopedic trauma surgery-incidence of adverse events related to technical equipment and logistics.

    PubMed

    van Delft, E A K; Schepers, T; Bonjer, H J; Kerkhoffs, G M M J; Goslings, J C; Schep, N W L

    2018-04-01

    Safety in the operating room is widely debated. Adverse events during surgery are potentially dangerous for the patient and staff. The incidence of adverse events during orthopedic trauma surgery is unknown. Therefore, we performed a study to quantify the incidence of these adverse events. Primary objective was to determine the incidence of adverse events related to technical equipment and logistics. The secondary objective was to evaluate the consequences of these adverse events. We completed a cross-sectional observational study to assess the incidence, consequences and preventability of adverse events related to technical equipment and logistics during orthopedic trauma surgery. During a 10 week period, all orthopedic trauma operations were evaluated by an observer. Six types of procedures were differentiated: osteosynthesis; arthroscopy; removal of hardware; joint replacement; bone grafting and other. Adverse events were divided in six categories: staff dependent factors; patient dependent factors; anaesthesia; imaging equipment; operation room equipment and instruments and implants. Adverse events were defined as any factor affecting the surgical procedure in a negative way. Hundred-fifty operative procedures were included. In 54% of the procedures, at least one adverse event occurred. In total, 147 adverse events occurred, with a range of 1-5 per procedure. Most adverse events occurred during joint replacement procedures. Thirty-seven percent of the incidents concerned defect, incorrect connected or absent instruments. In 36% of the procedures adverse events resulted in a prolonged operation time with a median prolongation of 10.0 min. In more than half of orthopedic trauma surgical procedures adverse events related to technical equipment and logistics occurred, most of them could easily be prevented. These adverse events could endanger the safety of the patient and staff and should therefore be reduced. 4.

  19. A residual granuloma in association with a dental implant.

    PubMed

    McCracken, Michael S; Chavali, Ramakiran V; Al-Naief, Nasser Said; Eleazer, Paul D

    2012-04-01

    At times, dental implants are placed into sites with a history of periapical pathology. Sometimes the infection is active, and other times the tooth may have been extracted years before implant placement. In either case, the possibility exists for long-term residual cysts or infections that can negatively impact the prognosis of the implant. In this case report, an implant is placed into a healed mandibular ridge several months after extraction of the tooth. A radiolucency was noted on routine radiographic examination 2 years later. Surgical inspection and histology revealed a periapical granuloma with acute and chronic inflammatory cells. After surgical curettage of the site, the patient healed without complication. Implants may develop apical pathology as a result of a preexisting long-term residual infection.

  20. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    PubMed Central

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  1. Selective etching of injection molded zirconia-toughened alumina: Towards osseointegrated and antibacterial ceramic implants.

    PubMed

    Flamant, Quentin; Caravaca, Carlos; Meille, Sylvain; Gremillard, Laurent; Chevalier, Jérôme; Biotteau-Deheuvels, Katia; Kuntz, Meinhard; Chandrawati, Rona; Herrmann, Inge K; Spicer, Christopher D; Stevens, Molly M; Anglada, Marc

    2016-12-01

    Due to their outstanding mechanical properties and excellent biocompatibility, zirconia-toughened alumina (ZTA) ceramics have become the gold standard in orthopedics for the fabrication of ceramic bearing components over the last decade. However, ZTA is bioinert, which hampers its implantation in direct contact with bone. Furthermore, periprosthetic joint infections are now the leading cause of failure for joint arthroplasty prostheses. To address both issues, an improved surface design is required: a controlled micro- and nano-roughness can promote osseointegration and limit bacterial adhesion whereas surface porosity allows loading and delivery of antibacterial compounds. In this work, we developed an integrated strategy aiming to provide both osseointegrative and antibacterial properties to ZTA surfaces. The micro-topography was controlled by injection molding. Meanwhile a novel process involving the selective dissolution of zirconia (selective etching) was used to produce nano-roughness and interconnected nanoporosity. Potential utilization of the porosity for loading and delivery of antibiotic molecules was demonstrated, and the impact of selective etching on mechanical properties and hydrothermal stability was shown to be limited. The combination of injection molding and selective etching thus appears promising for fabricating a new generation of ZTA components implantable in direct contact with bone. Zirconia-toughened alumina (ZTA) is the current gold standard for the fabrication of orthopedic ceramic components. In the present work, we propose an innovative strategy to provide both osseointegrative and antibacterial properties to ZTA surfaces: we demonstrate that injection molding allows a flexible design of surface micro-topography and can be combined with selective etching, a novel process that induces nano-roughness and surface interconnected porosity without the need for coating, avoiding reliability issues. These surface modifications have the

  2. Orthopedic Resident Anatomy Review Course: A Collaboration between Anatomists and Orthopedic Surgeons

    ERIC Educational Resources Information Center

    DeFriez, Curtis B.; Morton, David A.; Horwitz, Daniel S.; Eckel, Christine M.; Foreman, K. Bo; Albertine, Kurt H.

    2011-01-01

    A challenge for new residents and senior residents preparing for board examinations is refreshing their knowledge of basic science disciplines, such as human gross anatomy. The Department of Orthopaedics at the University of Utah School of Medicine has for many years held an annual Orthopedic Resident Anatomy Review Course during the summer months…

  3. Orthopedic trauma surgery in the morbidly obese patient.

    PubMed

    Bozzio, Anthony E; Gala, Raj J; Villasenor, Mario A; Hao, Jiandon; Mauffrey, Cyril

    2014-05-01

    The treatment of morbidly obese patients in orthopedic trauma differs in many ways compared to injured patients with normal body mass indices. This paper highlights key differences and ways to overcome obstacles. We present specific tips, as well as considerations for initial planning, positioning for surgery, intra-operative strategies, and a discussion on both anesthesia and imaging. Several treatment strategies have been shown to have better results in morbidly obese patients. Pre-operative planning is necessary for minimizing risk to the patient. The prevalence of morbid obesity has increased in the USA in the past quarter century. Treatment for orthopedic injuries in morbidly obese patients requires a multidisciplinary approach that addresses not only their orthopedic injuries, but also medical co-morbidities. A team of medicine doctors, anesthesiologists, X-ray technicians, physical and occupational therapists, respiratory therapists, and social workers is needed in addition to the orthopedic surgeon. Modifications in both pre-operative planning and intra-operative strategies may be necessary in order to accommodate the patient. This paper presents numerous technical tips that can aid in providing stable fixation for fractures, as well as addressing peri-operative issues specific to the morbidly obese.

  4. Antimicrobial and Antifouling Polymeric Agents for Surface Functionalization of Medical Implants.

    PubMed

    Zeng, Qiang; Zhu, Yiwen; Yu, Bingran; Sun, Yujie; Ding, Xiaokang; Xu, Chen; Wu, Yu-Wei; Tang, Zhihui; Xu, Fu-Jian

    2018-05-09

    Combating implant-associated infections is an urgent demand due to the increasing numbers in surgical operations such as joint replacements and dental implantations. Surface functionalization of implantable medical devices with polymeric antimicrobial and antifouling agents is an efficient strategy to prevent bacterial fouling and associated infections. In this work, antimicrobial and antifouling branched polymeric agents (GPEG and GEG) were synthesized via ring-opening reaction involving gentamicin and ethylene glycol species. Due to their rich primary amine groups, they can be readily coated on the polydopamine-modified implant (such as titanium) surfaces. The resultant surface coatings of Ti-GPEG and Ti-GEG produce excellent in vitro antibacterial efficacy toward both Staphylococcus aureus and Escherichia coli, while Ti-GPEG exhibit better antifouling ability. Moreover, the infection model with S. aureus shows that implanted Ti-GPEG possessed excellent antibacterial and antifouling ability in vivo. This study would provide a promising strategy for the surface functionalization of implantable medical devices to prevent implant-associated infections.

  5. Gender Disparities Within US Army Orthopedic Surgery: A Preliminary Report.

    PubMed

    Daniels, Christopher M; Dworak, Theodora C; Anderson, Ashley B; Brelin, Alaina M; Nesti, Leon J; McKay, Patricia L; Gwinn, David E

    2018-01-01

    Women account for approximately 15% of the active duty US Army, and studies show that women may be at an increased risk of musculoskeletal injury during sport and military training. Nationally, the field of orthopedic surgery comprises 14% women, lagging behind other surgical fields. Demographics for US Military orthopedic surgeons are not readily available. Similarly, demographic data of graduating medical students entering Military Medicine are not reported. We hypothesize that a gender disparity within military orthopedics will be apparent. We will compare the demographic profile of providers to our patients and hypothesize that the two groups are dissimilar. Secondarily, we examine the demographics of military medical students potentially entering orthopedics from the Uniformed Services University of the Health Sciences (USUHS) or the Health Professions Scholarship Program. A census was formed of all US Army active duty orthopedic surgeons to include staff surgeons and residents, as well as US Army medical student graduates and orthopedic patients. There are 252 Army orthopedic surgeons and trainees; 26 (10.3%) are women and 226 (89.7%) are men. There were no significant demographic differences between residents and staff. Between 2014 and 2017, the 672 members of the USUHS graduating classes included 246 Army graduates. Of those, 62 (25%) were female. Army Health Professions Scholarship Program graduated 1,072 medical students, with women comprising 300 (28%) of the group. No statistical trends were seen over the 4 yr at USUHS or in Health Professions Scholarship Program. In total, 2,993 orthopedic clinic visits during the study period were by Army service members, 23.6% were women. There exists a gender disparity among US Army orthopedic surgeons, similar to that seen in civilian orthopedics. Gender equity is also lacking among medical students who feed into Army graduate medical education programs. The gender profile of our patient population is not

  6. Trends in the orthopedic job market and the importance of fellowship subspecialty training.

    PubMed

    Morrell, Nathan T; Mercer, Deana M; Moneim, Moheb S

    2012-04-01

    Previous studies have examined possible incentives for pursuing orthopedic fellowship training, but we are unaware of previously published studies reporting the trends in the orthopedic job market since the acceptance of certain criteria for fellowship programs by the Accreditation Council for Graduate Medical Education (ACGME) in 1985. We hypothesized that, since the initiation of accredited postresidency fellowship programs, job opportunities for fellowship-trained orthopedic surgeons have increased and job opportunities for nonfellowship-trained orthopedic surgeons have decreased. We reviewed the job advertisements printed in the Journal of Bone and Joint Surgery, American Volume, for the years 1984, 1994, 2004, and 2009. We categorized the job opportunities as available for either a general (nonfellowship-trained) orthopedic surgeon or a fellowship-trained orthopedic surgeon. Based on the advertisements posted in the Journal of Bone and Joint Surgery, American Volume, a trend exists in the orthopedic job market toward seeking fellowship-trained orthopedic surgeons. In the years 1984, 1994, 2004, and 2009, the percentage of job opportunities seeking fellowship-trained orthopedic surgeons was 16.7% (95% confidence interval [CI], 13.1%-20.3%), 40.6% (95% CI, 38.1%-43.1%), 52.2% (95% CI, 48.5%-55.9%), and 68.2% (95% CI, 65.0%-71.4%), respectively. These differences were statistically significant (analysis of variance, P<.05). Fellowship training is thus a worthwhile endeavor. Copyright 2012, SLACK Incorporated.

  7. Publication Productivity of Early-Career Orthopedic Trauma Surgeons.

    PubMed

    Hake, Mark E; Lee, John J; Goulet, James A

    2016-01-01

    The goals of this study were to: (1) define the publication productivity of early-career orthopedic trauma surgeons over time; (2) compare the early-career publication productivity of recent orthopedic trauma fellowship graduates vs their more senior colleagues; and (3) determine the proportion of fellowship graduates who meet the Orthopaedic Trauma Association (OTA) publication criteria for active membership early in their careers. Orthopedic trauma fellowship graduates from 1982 to 2007 were analyzed. A literature search was performed for each fellow's publications for the 6-year period beginning the year of fellowship graduation. Publication productivity was compared between early and recent groups of graduates, 1987 to 1991 and 2003 to 2007, respectively. Fulfillment of OTA publication criteria was determined. Seventy-nine percent of graduates contributed to 1 or more publications. The recent group produced more total publications per graduate (4.06 vs 3.29, P=.01) and more coauthor publications (2.60 vs 2.04, P=.019) than the early group. The number of first-author publications did not differ between groups (1.46 vs 1.25, P=.26). A greater percentage of the recent group met current OTA publication criteria compared with the early group (51% vs 35%, P=.04). The findings showed that recent orthopedic trauma graduates had increased publication productivity compared with their more senior colleagues, although a proportion had not qualified for active OTA membership 6 years into their career. Overall, these data are encouraging and suggest that young orthopedic trauma surgeons remain committed to sustaining a high level of academic excellence. Copyright 2016, SLACK Incorporated.

  8. Redefining the Economics of Geriatric Orthopedics

    PubMed Central

    Nacca, Christopher; Paller, David; Daniels, Alan H

    2014-01-01

    Introduction: The heath care system in the United States is in the midst of a transition, in large part to help accommodate an older and more medically complex population. Central to the current evolution is the reassessment of value based on the cost utility of a particular procedure compared to alternatives. The existing contribution of geriatric orthopedics to the societal burden of disease is substantial, and literature focusing on the economic value of treating elderly populations with musculoskeletal injuries is growing. Materials and Methods: A literature review of peer-reviewed publications and abstracts related to the cost-effectiveness of treating geriatric patients with orthopedic injuries was carried out. Results: In our review, we demonstrate that while cost-utility studies generally demonstrate net society savings for most orthopedic procedures, geriatric populations often contribute to negative net society savings due to decreased working years and lower salaries while in the workforce. However, the incremental cost-effective ratio for operative intervention has been shown to be below the financial willingness to treat threshold for common procedures including joint replacement surgery of the knee (ICER US$8551), hip (ICER US$17 115), and shoulder (CE US$957) as well as for spinal procedures and repair of torn rotator cuffs (ICER US$12 024). We also discuss the current trends directed toward improving institutional value and highlight important complementary next steps to help overcome the growing demands of an older, more active society. Conclusion: The geriatric population places a significant burden on the health care system. However, studies have shown that treating this demographic for orthopedic-related injuries is cost effective and profitable for providers under certain scenarios. PMID:26246943

  9. Does the Implantation Technique for Totally Implantable Venous Access Ports (TIVAPs) Influence Long-Term Outcome?

    PubMed

    Biacchi, Daniele; Sammartino, Paolo; Sibio, Simone; Accarpio, Fabio; Cardi, Maurizio; Sapienza, Paolo; De Cesare, Alessandro; Atta, Joseph Maher Fouad; Impagnatiello, Alessio; Di Giorgio, Angelo

    2016-02-01

    Totally implantable venous access ports (TIVAP) are eventually explanted for various reasons, related or unrelated to the implantation technique used. Having more information on long-term explantation would help improve placement techniques. From a series of 1572 cancer patients who had TIVAPs implanted in our center with the cutdown technique or Seldinger technique, we studied the 542 patients who returned to us to have their TIVAP explanted after 70 days or more. As outcome measures we distinguished between TIVAPs explanted for long-term complications (infection, catheter-, reservoir-, and patient-related complications) and TIVAPs no longer needed. Univariate and multivariate analyses were run to investigate the reasons for explantation and their possible correlation with implantation techniques. The most common reason for explantation was infection (47.6 %), followed by catheter-related (20.8 %), patient-related (14.7 %), and reservoir-related complications (4.7 %). In the remaining 12.2 % of cases, the TIVAP was explanted complication free after the planned treatments ended. Infection correlated closely with longer TIVAP use. Univariate and multivariate analyses identified the Seldinger technique as a major risk factor for venous thrombosis and catheter dislocation. The need for long-term TIVAP explantation in about one-third of cancer patients is related to the implantation techniques used.

  10. Wireless implantable passive strain sensor: design, fabrication and characterization

    NASA Astrophysics Data System (ADS)

    Umbrecht, F.; Wägli, P.; Dechand, S.; Gattiker, F.; Neuenschwander, J.; Sennhauser, U.; Hierold, Ch

    2010-08-01

    This work presents a new passive sensor concept for monitoring the deformation of orthopedic implants. The novel sensing principle of the WIPSS (wireless implantable passive strain sensor) is based on a hydro-mechanical amplification effect. The WIPSS is entirely made from biocompatible PMMA and consists of a microchannel attached to a reservoir, which is filled with an incompressible fluid. As the reservoir is exposed to strain, its volume changes and consequently the fill level inside the microchannel varies. The wireless detection of the microchannel's strain-dependent fill level is based on ultrasound. The WIPSS' sensing principle is proved by finite-element simulations and the reservoir's design is optimized toward maximum volume change, in order to achieve high sensitivity. A fabrication process for WIPSS sensor devices entirely made from PMMA is presented. The obtained measurement results confirmed the sensor's functionality and showed very good agreement with the obtained results of the conducted FE simulations regarding the sensor's sensitivity. A strain resolution of 1.7 ± 0.2 × 10-5 was achieved. Further, the determination of the cross-sensitivity to temperature and strains applied out of the sensing direction is presented. The response to dynamic inputs (0.1-5 Hz) has been measured and showed decreasing sensor output with increasing frequency. Test structures of the sensor device allow the application of a signal bandwidth up to 1 Hz. Therefore, the proposed sensor concept of the WIPSS presents a promising new sensor system for static in vivo strain monitoring of orthopedic implants. In combination with the developed ultrasound-based read-out method, this new sensor system offers the potential of wireless sensor read-out with medical ultrasound scanners, which are commercially available.

  11. Comparison of mechanical behavior between implant-simulated bone tissue and implant-jaw bone tissue interfaces based on Pull Out testing

    NASA Astrophysics Data System (ADS)

    Lopez, C.; Muñoz, J. C.; Pinillos, J. C.

    2013-11-01

    The main purpose of this research was to achieve a better understanding of the relationship within the mechanical properties of human cadaver jaw bone with kind D2 density regarding a substitute polymer to simulate bone tissue, proposed by the ASTM, to evaluate orthopedic implants. However, despite the existence of several densities of foams and his mechanical characterization has been classified into different degrees of tissue densities to simulate cancellous and cortical bone, the value of the densities are different contrasted with the densities of bone tissue, making difficult to establish direct relationship about mechanical behavior between the polymer and the bone material, and therefore no clear criteria known for choosing the polymeric foam which describes the mechanical behavior of tissue for a specific or particular study. To understand such behavior from bone tissue regarding the polymer samples, on this research was a dental implant inserted into the samples, and subjected to destructive Pull Out test according to ASTM F543The Pull Out strength was compared between implant-jawbone and implant-rigid polyurethane foam interfaces. Thus, the test pieces with mechanical behavior similar to bone tissue, enabling an approximation to choose degree appropriate of polymer to replace the bone tissue in future trials biomechanical.

  12. Orthopedic surgery in rheumatoid arthritis in the era of biologic therapy.

    PubMed

    Leon, Leticia; Abasolo, Lydia; Carmona, Loreto; Rodriguez-Rodriguez, Luis; Lamas, Jose Ramon; Hernandez-Garcia, Cesar; Jover, Juan Angel

    2013-11-01

    To analyze sociodemographic and clinic-related factors associated with the use of orthopedic surgical procedures in rheumatoid arthritis (RA), focusing on the potential role of new biologic therapies. A retrospective medical record review was performed in a probability sample of 1272 patients with RA from 47 units distributed in 19 Spanish regions. Sociodemographic and clinical features, use of drugs, and arthritis-related joint surgeries were recorded following a standardized protocol. A total of 94 patients (7.4%) underwent any orthopedic surgery during their disease course, with a total of 114 surgeries; 47 (41.2%) of these surgeries were total joint replacement (TJR). The median time to first orthopedic procedure was 7.9 years from the onset of RA symptoms, and the rate of orthopedic surgery (excluding TJR) was 4.5 procedures per 100 person-years from the beginning of RA, while the rate of TJR was 2.25 interventions per 100 person-years. A higher risk of undergoing an orthopedic surgical procedure was associated with taking nonsteroidal antiinflammatory drugs (NSAID) in the previous 2 years, female sex, longterm disease, and the presence of extraarticular complications. The risk factors for undergoing a TJR were being old, having a longterm disease, and taking biologic therapies. In the era of biologics, our national audit found a low percentage of patients who underwent orthopedic surgery, probably reflecting a thorough management of the RA. Sociodemographic factors, longterm RA, extraarticular complications, and NSAID were associated with orthopedic surgery.

  13. Silver Coordination Polymers for Prevention of Implant Infection: Thiol Interaction, Impact on Respiratory Chain Enzymes, and Hydroxyl Radical Induction▿ †

    PubMed Central

    Gordon, Oliver; Vig Slenters, Tünde; Brunetto, Priscilla S.; Villaruz, Amer E.; Sturdevant, Daniel E.; Otto, Michael; Landmann, Regine; Fromm, Katharina M.

    2010-01-01

    Prosthetic joint replacements are used increasingly to alleviate pain and improve mobility of the progressively older and more obese population. Implant infection occurs in about 5% of patients and entails significant morbidity and high social costs. It is most often caused by staphylococci, which are introduced perioperatively. They are a source of prolonged seeding and difficult to treat due to antibiotic resistance; therefore, infection prevention by prosthesis coating with nonantibiotic-type anti-infective substances is indicated. A renewed interest in topically used silver has fostered development of silver nanoparticles, which, however, present a potential health hazard. Here we present new silver coordination polymer networks with tailored physical and chemical properties as nanostructured coatings on metallic implant substrates. These compounds exhibited strong biofilm sugar-independent bactericidal activity on in vitro-grown biofilms and prevented murine Staphylococcus epidermidis implant infection in vivo with slow release of silver ions and limited transient leukocyte cytotoxicity. Furthermore, we describe the biochemical and molecular mechanisms of silver ion action by gene screening and by targeting cell metabolism of S. epidermidis at different levels. We demonstrate that silver ions inactivate enzymes by binding sulfhydryl (thiol) groups in amino acids and promote the release of iron with subsequent hydroxyl radical formation by an indirect mechanism likely mediated by reactive oxygen species. This is the first report investigating the global metabolic effects of silver in the context of a therapeutic application. We anticipate that the compounds presented here open a new treatment field with a high medical impact. PMID:20660682

  14. Susceptibility of metallic magnesium implants to bacterial biofilm infections.

    PubMed

    Rahim, Muhammad Imran; Rohde, Manfred; Rais, Bushra; Seitz, Jan-Marten; Mueller, Peter P

    2016-06-01

    Magnesium alloys have promising mechanical and biological properties as biodegradable medical implant materials for temporary applications during bone healing or as vascular stents. Whereas conventional implants are prone to colonization by treatment resistant microbial biofilms in which bacteria are embedded in a protective matrix, magnesium alloys have been reported to act antibacterial in vitro. To permit a basic assessment of antibacterial properties of implant materials in vivo an economic but robust animal model was established. Subcutaneous magnesium implants were inoculated with bacteria in a mouse model. Contrary to the expectations, bacterial activity was enhanced and prolonged in the presence of magnesium implants. Systemic antibiotic treatments were remarkably ineffective, which is a typical property of bacterial biofilms. Biofilm formation was further supported by electron microscopic analyses that revealed highly dense bacterial populations and evidence for the presence of extracellular matrix material. Bacterial agglomerates could be detected not only on the implant surface but also at a limited distance in the peri-implant tissue. Therefore, precautions may be necessary to minimize risks of metallic magnesium-containing implants in prospective clinical applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1489-1499, 2016. © 2016 Wiley Periodicals, Inc.

  15. Concurrent orthopedic and neurosurgical procedures in pediatric patients with spinal deformity.

    PubMed

    Mooney, James F; Glazier, Stephen S; Barfield, William R

    2012-11-01

    The management of pediatric patients with complex spinal deformity often requires both an orthopedic and a neurosurgical intervention. The reasons for multiple subspecialty involvement include, but are not limited to, the presence of a tethered cord requiring release or a syrinx requiring decompression. It has been common practice to perform these procedures in a staged manner, although there is little evidence in the literature to support separate interventions. We reviewed a series of consecutive patients who underwent spinal deformity correction and a neurosurgical intervention concurrently in an attempt to assess the safety, efficacy, and possible complications associated with such an approach. Eleven patients were reviewed who underwent concurrent orthopedic and neurosurgical procedures. Data were collected for patient demographics, preoperative diagnosis, procedures performed, intraoperative and perioperative complications, as well as any unexpected return to the operating room for any reason. Operative notes and anesthesia records were reviewed to determine estimated blood loss, surgical time, and the use of intraoperative neurological monitoring. Patient diagnoses included myelodysplasia (N=6), congenital scoliosis and/or kyphosis (N=4), and scoliosis associated with Noonan syndrome (N=1). Age at the time of surgery averaged 9 years 2 months (range=14 months to 17 years 2 months). Estimated blood loss averaged 605 ml (range=50-3000 ml). The operative time averaged 313 min (range=157-477 min). There were no intraoperative complications, including incidental dural tears or deterioration in preoperative neurological status. One patient developed a sore associated with postoperative cast immobilization that led to a deep wound infection. It appears that concurrent orthopedic and neurosurgical procedures in pediatric patients with significant spinal deformities can be performed safely and with minimal intraoperative and postoperative complications when utilizing

  16. Analgesics for orthopedic postoperative pain.

    PubMed

    Bourne, Michael H

    2004-03-01

    Postoperative pain management is critical for optimal care of orthopedic surgery patients. Opioids, administered intramuscularly, as epidurals, or IV as patient-controlled analgesia, are effective for severe pain. Adjunctive therapy and preemptive analgesia such as nerve blocks, and methods of delivery such as infusion pumps, may be used after total knee arthroplasty and anterior cruciate ligament (ACL) reconstruction. Oral opioids are effective for moderate to severe pain, and tramadol, with efficacy comparable to morphine but with fewer severe side effects, is selected for moderate to moderately severe pain. Opioid-sparing NSAIDs, such as ketorolac, and COX-2-specific NSAIDS have use in pain management of hip, knee, and ACL procedures. An individualized regimen of appropriate analgesics, combined with nonpharmacologic treatments such as physical therapy or cryotherapy and patient education, can aid orthopedic surgery patients' recovery.

  17. Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study

    PubMed Central

    Harrysson, Ola LA; Hosni, Yasser A; Nayfeh, Jamal F

    2007-01-01

    Background Conventional knee and hip implant systems have been in use for many years with good success. However, the custom design of implant components based on patient-specific anatomy has been attempted to overcome existing shortcomings of current designs. The longevity of cementless implant components is highly dependent on the initial fit between the bone surface and the implant. The bone-implant interface design has historically been limited by the surgical tools and cutting guides available; and the cost of fabricating custom-designed implant components has been prohibitive. Methods This paper describes an approach where the custom design is based on a Computed Tomography scan of the patient's joint. The proposed design will customize both the articulating surface and the bone-implant interface to address the most common problems found with conventional knee-implant components. Finite Element Analysis is used to evaluate and compare the proposed design of a custom femoral component with a conventional design. Results The proposed design shows a more even stress distribution on the bone-implant interface surface, which will reduce the uneven bone remodeling that can lead to premature loosening. Conclusion The proposed custom femoral component design has the following advantages compared with a conventional femoral component. (i) Since the articulating surface closely mimics the shape of the distal femur, there is no need for resurfacing of the patella or gait change. (ii) Owing to the resulting stress distribution, bone remodeling is even and the risk of premature loosening might be reduced. (iii) Because the bone-implant interface can accommodate anatomical abnormalities at the distal femur, the need for surgical interventions and fitting of filler components is reduced. (iv) Given that the bone-implant interface is customized, about 40% less bone must be removed. The primary disadvantages are the time and cost required for the design and the possible need

  18. Dental Implant Complications.

    PubMed

    Liaw, Kevin; Delfini, Ronald H; Abrahams, James J

    2015-10-01

    Dental implants have increased in the last few decades thus increasing the number of complications. Since many of these complications are easily diagnosed on postsurgical images, it is important for radiologists to be familiar with them and to be able to recognize and diagnose them. Radiologists should also have a basic understanding of their treatment. In a pictorial fashion, this article will present the basic complications of dental implants which we have divided into three general categories: biomechanical overload, infection or inflammation, and other causes. Examples of implant fracture, loosening, infection, inflammation from subgingival cement, failure of bone and soft tissue preservation, injury to surround structures, and other complications will be discussed as well as their common imaging appearances and treatment. Lastly, we will review pertinent dental anatomy and important structures that are vital for radiologists to evaluate in postoperative oral cavity imaging. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Survey of 2582 Cases of Acute Orthopedic Trauma

    PubMed Central

    Soleymanha, Mehran; Mobayen, Mohammadreza; Asadi, Kamran; Adeli, Alborz; Haghparast-Ghadim-Limudahi, Zahra

    2014-01-01

    Background: Orthopedic injuries are among the most common causes of mortality, morbidity, hospitalization, and economic burden in societies. Objectives: In this research, we study the prevalence of different types of trauma requiring orthopedic surgery. Patients and Methods: We conducted a cross-sectional study on 2582 patients with acute orthopedic injuries admitted to the orthopedic emergency ward at the Poursina Hospital (a referral center in Guilan province (northern Iran), during December 2010 through September 2011. Patients were examined and the data collection form was filled for each patient. Data were analyzed by SPSS software version 19 and were listed in tables. Results: Of 2582 included cases, 1940 were male and 642 were female, with a mean age of 34.5 years. Most injuries were seen in the 25 to 44 year age group from rural areas. The highest frequency of trauma related to falls. On the other hand, bicycling and shooting had the lowest frequencies. There were 18 cases with limb amputation. Overall, 66.5% of patients had fractures, 5% had soft tissue lacerations, and 10% had dislocations. Conclusions: Identification of risk factors and methods of prevention is one of the most important duties of healthcare systems. Devising plans to minimize these risk factors and familiarizing people with them is prudent. PMID:25717444

  20. Patch testers' opinions regarding diagnostic criteria for metal hypersensitivity reactions to metallic implants.

    PubMed

    Schalock, Peter C; Thyssen, Jacob P

    2013-01-01

    Metal hypersensitivity reactions to implanted devices remain a challenging and controversial topic. Diagnostic criteria and methods are not well delineated. Diagnostic criteria for hypersensitivity reactions after metallic device implantation are evaluated in this study by a multinational group of patch testers using Thyssen's previously published criteria. A total of 119 dermatologists at the 2012 European Contact Dermatitis Society and 2013 American Contact Dermatitis Society meetings answered a survey regarding their opinions on topics relating to metal hypersensitivity. Four major and 5 minor diagnostic criteria emerged. Approximately 80% of respondents found the following criteria useful (major criteria): chronic dermatitis beginning weeks to months after metallic implantation, eruption overlying the metal implant, positive patch test to a metal component of the implant, and complete clearing after removal of the potentially allergenic implant. Minor criteria (<61% of respondents) were as follows: systemic allergic dermatitis reaction, therapy-resistant dermatitis, morphology consistent with dermatitis, histology consistent with allergic contact dermatitis, and a positive in vitro test to metals (eg, lymphocyte transformation test). In the challenging situation such as a symptomatic or failing orthopedic device, applying these 4 major criteria and the 5 supportive minor criteria may be useful for guiding decision making.

  1. Anxiety in the orthopedic patient: using PROMIS to assess mental health.

    PubMed

    Beleckas, Casey M; Prather, Heidi; Guattery, Jason; Wright, Melissa; Kelly, Michael; Calfee, Ryan P

    2018-05-08

    This study explored the performance of the Patient-Reported Outcomes Measurement Information System (PROMIS) Anxiety assessment relative to the Depression assessment in orthopedic patients, the relationship between Anxiety with self-reported Physical Function and Pain Interference, and to determine if Anxiety levels varied according to the location of orthopedic conditions. This cross-sectional evaluation analyzed 14,962 consecutive adult new-patient visits to a tertiary orthopedic practice between 4/1/2016 and 12/31/2016. All patients completed PROMIS Anxiety, Depression, Physical Function, and Pain Interference computer adaptive tests (CATs) as routine clinical intake. Patients were grouped by the orthopedic service providing care and categorized as either affected with Anxiety if scoring > 62 based on linkage to the Generalized Anxiety Disorder-7 survey. Spearman correlations between the PROMIS scores were calculated. Bivariate statistics assessed differences in Anxiety and Depression scores between patients of different orthopedic services. 20% of patients scored above the threshold to be considered affected by Anxiety. PROMIS Anxiety scores demonstrated a stronger correlation than Depression scores with Physical Function and Pain Interference scores. Patients with spine conditions reported the highest median Anxiety scores and were more likely to exceed the Anxiety threshold than patients presenting to sports or upper extremity surgeons. One in five new orthopedic patients reports Anxiety levels that may warrant intervention. This rate is heightened in patients needing spine care. Patient-reported Physical Function more strongly correlates with PROMIS Anxiety than Depression suggesting that the Anxiety CAT is a valuable addition to assess mental health among orthopedic patients. Diagnostic level III.

  2. Influence of podiatry on orthopedic surgery at a level I trauma center.

    PubMed

    Jakoi, Andre M; Old, Andrew B; O'Neill, Craig A; Stein, Benjamin E; Stander, Eric P; Rosenblatt, Joseph; Herman, Martin J

    2014-06-01

    Level I trauma centers frequently see trauma at or below the ankle, which requires consultation with the orthopedic surgery department. However, as podiatry programs begin to firmly establish themselves in more Level I trauma centers, their consultations increase, ultimately taking those once seen by orthopedic surgery. A review of the literature demonstrates that this paradigm shift has yet to be discussed. The purpose of this study was to determine how many, if any, lower extremity fracture consultations a newly developed podiatry program would take from the orthopedic surgery department. A retrospective review was performed of emergency department records from January 2007 to December 2011. Seventeen different emergency department diagnoses were used to search the database. Ultimately, each patient's emergency department course was researched. Several trends were noted. First, if trauma surgery was involved, only the orthopedic surgery department was consulted for any injuries at or below the ankle. Second, the emergency department tended to consult the podiatry program only between the hours of 8 am and 6 pm. Third, as the podiatry program became more established, their number of consultations increased yearly, and, coincidentally, the orthopedic surgery department's consultations decreased. Finally, high-energy traumas involved only the orthopedic surgery department. Whether the orthopedic surgery department or podiatry program is consulted regarding trauma surgery is likely hospital dependent. Copyright 2014, SLACK Incorporated.

  3. Preparedness Evaluation of French Military Orthopedic Surgeons Before Deployment.

    PubMed

    Choufani, Camille; Barbier, Olivier; Mayet, Aurélie; Rigal, Sylvain; Mathieu, Laurent

    2018-06-13

    A deployed military orthopedic surgeon is a trauma surgeon working in austere conditions. The first aim of this study was to analyze the current activity of French military orthopedic surgeons in the field and to identify the differences of the combat zone with their daily practice. The second aim was to assess the adequacy of the preparedness they received before their deployment and to identify additional needs that could be addressed in future training. An evaluation survey was sent to all French military orthopedic surgeons deployed in theaters of operations between 2004 and 2014. An analogic visual scale of 10 was used to evaluate their surgical activity abroad and prior training. A total of 55 surgeons, with a median deployment number of 7, were included in this study after they answered the survey. Debridement and external fixation were the most common orthopedic procedures. The practice of general surgery was mostly concerned with vascular and abdominal injuries as part of damage control procedures. Median scores were ranked at seven for surgical preparedness, five for physical readiness, and three for mental preparedness. There was a significant inverse relationship between the number of missions performed and the evaluation of surgical preparedness. The higher they perceived their mental preparedness, the better they estimated their surgical preparedness. In the French Army, deployed orthopedic surgeons perform general surgical activity. Their initial training must be adapted to this constraint and enhanced by continuing medical education.

  4. [Orthopedics and patients under national socialism dictatorship].

    PubMed

    Thomann, K D; Rauschmann, M

    2001-10-01

    The 12-year dictatorship of National Socialism represents a decisive event in the history of orthopedics in Germany. Treatment and care was limited to those patients whose prognosis promised their reintegration into the work force. Those orthopedic patients with mental and psychological handicaps no longer came under the care of orthopedists and were potential candidates for annihilation. Despite concerted efforts to the contrary, as can be gleaned from the lists of topics at the annual meetings, the prevailing political circumstances encumbered scientific activities. The almost total isolation from international contacts had a negative effect. Orthopedists were hindered in their work by the law on sterilization, which provided for sterilization in cases of severe physical deformity. Some orthopedists even considered the presence of hip dysplasia to be an indication. The roles played by Georg Hohmann, Hellmut Eckhardt, Lothar Kreuz, and other leading orthopedists are described in detail. It can be regarded as certain that Hohmann and Eckhardt were able to prevent dire consequences for their orthopedic patients and the profession by cautious tactics. The ethnical problems of involvement with National Socialism are thoroughly discussed.

  5. Penile Implants

    MedlinePlus

    ... ED that's situational, the result of a relationship conflict or potentially reversible An infection, such as a ... your partner in the discussion with your doctor. Types of penile implants There are two main types ...

  6. Characterization and antibacterial performance of electrodeposited chitosan-vancomycin composite coatings for prevention of implant-associated infections.

    PubMed

    Ordikhani, F; Tamjid, E; Simchi, A

    2014-08-01

    Orthopaedic implant-associated infections are one of the most serious complications in orthopaedic surgery and a major cause of implant failure. In the present work, drug-eluting coatings based on chitosan containing various amounts of vancomycin were prepared by a cathodic electrophoretic deposition process on titanium foils. A three-step release mechanism of the antibiotic from the films in a phosphate-buffered saline solution was noticed. At the early stage, physical encapsulation of the drug in the hydrogel network controlled the release rate. At the late stage, however, in vitro degradation/deattachment of chitosan was responsible for the controlled release. Cytotoxicity evaluation of the drug-eluting coatings via culturing in human osteosarcoma cells (MG-63 osteoblast-like cell line) showed no adverse effect on the biocompatibility. Antibacterial tests against Gram-positive Staphylococcus aureus also demonstrated that the infection risk of titanium foils was significantly reduced due to the antibiotic release. Additionally, in vitro electrochemical corrosion studies by polarization technique revealed that the corrosion current density was significantly lower for the titanium foils with drug-eluting coatings compared to that of uncoated titanium. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Customizable cap implants for neurophysiological experimentation.

    PubMed

    Blonde, Jackson D; Roussy, Megan; Luna, Rogelio; Mahmoudian, Borna; Gulli, Roberto A; Barker, Kevin C; Lau, Jonathan C; Martinez-Trujillo, Julio C

    2018-04-22

    Several primate neurophysiology laboratories have adopted acrylic-free, custom-fit cranial implants. These implants are often comprised of titanium or plastic polymers, such as polyether ether ketone (PEEK). Titanium is favored for its mechanical strength and osseointegrative properties whereas PEEK is notable for its lightweight, machinability, and MRI compatibility. Recent titanium/PEEK implants have proven to be effective in minimizing infection and implant failure, thereby prolonging experiments and optimizing the scientific contribution of a single primate. We created novel, customizable PEEK 'cap' implants that contour to the primate's skull. The implants were created using MRI and/or CT data, SolidWorks software and CNC-machining. Three rhesus macaques were implanted with a PEEK cap implant. Head fixation and chronic recordings were successfully performed. Improvements in design and surgical technique solved issues of granulation tissue formation and headpost screw breakage. Primate cranial implants have traditionally been fastened to the skull using acrylic and anchor screws. This technique is prone to skin recession, infection, and implant failure. More recent methods have used imaging data to create custom-fit titanium/PEEK implants with radially extending feet or vertical columns. Compared to our design, these implants are more surgically invasive over time, have less force distribution, and/or do not optimize the utilizable surface area of the skull. Our PEEK cap implants served as an effective and affordable means to perform electrophysiological experimentation while reducing surgical invasiveness, providing increased strength, and optimizing useful surface area. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  8. [Osteosynthesis-associated infections : Epidemiology, definition and diagnosis].

    PubMed

    Renz, N; Feihl, S; Dlaska, C E; Schütz, M A; Trampuz, A

    2017-06-01

    Osteosynthesis-associated infections occur in 1-5% after closed and in up to 30% after open fractures. There are three different descriptions of implant-associated infections after fracture fixation, which are crucial for the selection of the adequate treatment strategy; temporal appearance from the index surgery (early versus late), pathogenesis of the infection (exogenous, hematogenous and contiguous from an adjacent focus), duration of infection symptoms (acute versus chronic). Diagnosis of osteosynthesis-associated infection is challenging, as chronic low-grade infections often present only with unspecific and subtle clinical symptoms. History, clinical evaluation, imaging, histopathlogical and microbiological examination build the cornerstones of diagnostics in implant-associated infections. A new onset of rest pain, early loosening of the prosthesis or mechanically unexplained, nonunion should raise suspicion for infection and prompt further evaluation. Percutaneous sinus tracts, purulent wound secretion and skin erosions with visibility of the implant confirm the implant-associated infection. Elevated C‑reactive protein value in blood is a supportive argument for infection, but is neither sensitive nor specific for infection. Imaging plays a key role to detect nonunions, infectious callus, sequester, peri-implant osteolysis and extraosseous and intramedullary involvement. Through microbiological and histopathological examination of intraoperative tissue samples, as well as sonication of explanted implants the causative pathogen is identified in most cases.

  9. Immediate Titanium Mesh Implantation for Patients with Postcraniotomy Neurosurgical Site Infections: Safe and Aesthetic Alternative Procedure?

    PubMed

    Ehrlich, Gregory; Kindling, Stefanie; Wenz, Holger; Hänggi, Daniel; Schulte, Dirk Michael; Schmiedek, Peter; Seiz-Rosenhagen, Marcel

    2017-03-01

    Surgical site infection (SSI) is one of the main complications after craniotomy. The incidence is up to 11% in the literature. The established procedure is debridement, removal of the bone flap, and delayed cranioplasty. Delayed cranioplasty has several disadvantages. A promising approach is the immediate titanium mesh implantation at the time of wound revision. We report our experience with this technique regarding outcome measured by reinfection rates and patient satisfaction. Patients treated in our department from January 2013 to October 2014 with SSI after craniotomy for brain tumor, trauma, or vascular pathologies were prospectively collected. In all these patients, immediate titanium mesh implantation after bone flap removal was performed. Primary outcome parameters were the reinfection rate and patient satisfaction via self-designed questionnaires in a follow-up period >3 months. Twenty-four patients were included within the study period. Main risk factors causing SSI were previous steroid medication (62.5%), cranial radiation therapy (42%), cerebrospinal fluid fistula after initial surgery (12.5%), and diabetes mellitus (25%). The follow-up was >3 months after titanium mesh cranioplasty (mean 4.6 months; range 3-6 months). No recurrent infection was detected in the study group. In 2 cases, reoperation was necessary. The returning questionnaires showed a high satisfaction rate with the cosmetic result. Our small series seems to confirm that immediate titanium mesh implantation for patients with postcraniotomy SSI is a cost-effective, safe, and cosmetically suitable alternative to delayed cranioplasty in selected patients without hydrocephalus or persistent cerebrospinal fluid fistula. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. An Orthopedic Performance Improvement Initiative at a Small Military Treatment Facility.

    PubMed

    McGee, John Christopher; Bise, Christopher G; Stevens, Joel M

    2017-03-01

    The scientific literature demonstrates a cost-benefit associated with early access to physical therapy. The purpose of this case study is to report the results of an orthopedic performance improvement initiative (OPII) at a small military treatment facility (approximately 4.5K active duty beneficiaries). The OPII was introduced to (1) limit variation by ensuring that all active duty orthopedic consults were audited ensuring proper timing of appropriate services and (2) establish contractual agreement for shared resources with the U.S. Naval Jacksonville Orthopedic Department. OPII was accomplished through consensus development and strong leadership support. All orthopedic referrals (n = 260) were audited for 6 months. Appropriate recommendations were provided to either continue with orthopedic care or to redirect to a physical therapy first approach. Orthopedic referrals decreased 27% with concomitant 32% increase in physical therapy referrals producing overall savings of $462K (33%). Meanwhile, surgical throughput improved 45%. Seventy percent of the savings were attributed to improved utilization translating to a relative value unit savings per beneficiary of $17.64 (23.7%). Our results support the value of a conservative physical therapy first approach for musculoskeletal conditions and shared mil-to-mil resourcing agreements. Success requires an iterative audit/feedback process balanced with stakeholder consensus. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  11. Orthopedic surgeons' knowledge regarding risk of radiation exposition: a survey analysis.

    PubMed

    Tunçer, Nejat; Kuyucu, Ersin; Sayar, Şafak; Polat, Gökhan; Erdil, İrem; Tuncay, İbrahim

    2017-01-01

    The purpose of this study is to evaluate the knowledge levels of orthopedic surgeons working in Turkey about the uses and possible risks of fluoroscopy and assess methods for preventing radiation damage. A questionnaire with a total of 12 questions was sent to 1121 orthopedic surgeons working in Turkey. The questionnaire evaluated participants' knowledge about the uses and risks of fluoroscopy and methods for preventing damage. One thousand and twenty-four orthopedic surgeons were found to be suitable for inclusion in the study. The effects of fluoroscopy on patients were not assessed in our study. The data obtained were statistically evaluated. Of the surveyed surgeons, 313 (30%) had used fluoroscopy in over 50% of their operations. The average number of fluoroscopy shots per case was 54.5. A lead apron was the most commonly used (88%) protection from the harmful effects of radiation. Fluoroscopy shots were performed with the help of operating room personnel (86%). A dosimeter was used 5% of the time. According to the survey results, the need for fluoroscopy was very high in orthopedic surgery. However, orthopedic surgeons have inadequate knowledge about the uses and risks of fluoroscopy and methods for preventing damage. Therefore, we believe that training on this topic should be provided to all orthopedic surgeons. © The Authors, published by EDP Sciences, 2017.

  12. Immediate direct-to-implant breast reconstruction using anatomical implants.

    PubMed

    Kim, Sung-Eun; Jung, Dong-Woo; Chung, Kyu-Jin; Lee, Jun Ho; Kim, Tae Gon; Kim, Yong-Ha; Lee, Soo Jung; Kang, Su Hwan; Choi, Jung Eun

    2014-09-01

    In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  13. Differential sensitivity of osteoblasts and bacterial pathogens to 405-nm light highlighting potential for decontamination applications in orthopedic surgery

    NASA Astrophysics Data System (ADS)

    Ramakrishnan, Praveen; Maclean, Michelle; MacGregor, Scott J.; Anderson, John G.; Grant, M. Helen

    2014-10-01

    Healthcare associated infections pose a major threat to patients admitted to hospitals and infection rates following orthopedic arthroplasty surgery are as high as 4%. A 405-nm high-intensity narrow spectrum light has been proven to reduce environmental contamination in hospital isolation rooms, and there is potential to develop this technology for application in arthroplasty surgery. Cultured rat osteoblasts were exposed to varying light intensities and it was found that exposures of up to a dose of 36 J/cm2 had no significant effect on cell viability [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay], function (alkaline phosphatase activity), and proliferation rate (BrdU cell proliferation assay). High irradiance exposures (54 J/cm2) significantly affected the cell viability indicating that the effects of 405-nm light on osteoblasts are dose dependent. Additionally, exposure of a variety of clinically related bacteria to a dose of 36 J/cm2 resulted in up to 100% kill. These results demonstrating the differential sensitivity of osteoblasts and bacteria to 405-nm light are an essential step toward developing the technique for decontamination in orthopedic surgery.

  14. Rare Infections: Yersinia Enterocolitica and Yersinia Pseudotuberculosis

    MedlinePlus

    ... Life Family Life Family Life Medical Home Family Dynamics Media Work & Play Getting Involved in Your Community ... and Urinary Tract Glands & Growth Head Neck & Nervous System Heart Infections Learning Disabilities Obesity Orthopedic Prevention Sexually ...

  15. E-Coli Infection: Not Just from Food

    MedlinePlus

    ... Life Family Life Family Life Medical Home Family Dynamics Media Work & Play Getting Involved in Your Community ... and Urinary Tract Glands & Growth Head Neck & Nervous System Heart Infections Learning Disabilities Obesity Orthopedic Prevention Sexually ...

  16. Molecular imaging promotes progress in orthopedic research.

    PubMed

    Mayer-Kuckuk, Philipp; Boskey, Adele L

    2006-11-01

    Modern orthopedic research is directed towards the understanding of molecular mechanisms that determine development, maintenance and health of musculoskeletal tissues. In recent years, many genetic and proteomic discoveries have been made which necessitate investigation under physiological conditions in intact, living tissues. Molecular imaging can meet this demand and is, in fact, the only strategy currently available for noninvasive, quantitative, real-time biology studies in living subjects. In this review, techniques of molecular imaging are summarized, and applications to bone and joint biology are presented. The imaging modality most frequently used in the past was optical imaging, particularly bioluminescence and near-infrared fluorescence imaging. Alternate technologies including nuclear and magnetic resonance imaging were also employed. Orthopedic researchers have applied molecular imaging to murine models including transgenic mice to monitor gene expression, protein degradation, cell migration and cell death. Within the bone compartment, osteoblasts and their stem cells have been investigated, and the organic and mineral bone phases have been assessed. These studies addressed malignancy and injury as well as repair, including fracture healing and cell/gene therapy for skeletal defects. In the joints, molecular imaging has focused on the inflammatory and tissue destructive processes that cause arthritis. As described in this review, the feasibility of applying molecular imaging to numerous areas of orthopedic research has been demonstrated and will likely result in an increase in research dedicated to this powerful strategy. Molecular imaging holds great promise in the future for preclinical orthopedic research as well as next-generation clinical musculoskeletal diagnostics.

  17. An advanced simulator for orthopedic surgical training.

    PubMed

    Cecil, J; Gupta, Avinash; Pirela-Cruz, Miguel

    2018-02-01

    The purpose of creating the virtual reality (VR) simulator is to facilitate and supplement the training opportunities provided to orthopedic residents. The use of VR simulators has increased rapidly in the field of medical surgery for training purposes. This paper discusses the creation of the virtual surgical environment (VSE) for training residents in an orthopedic surgical process called less invasive stabilization system (LISS) surgery which is used to address fractures of the femur. The overall methodology included first obtaining an understanding of the LISS plating process through interactions with expert orthopedic surgeons and developing the information centric models. The information centric models provided a structured basis to design and build the simulator. Subsequently, the haptic-based simulator was built. Finally, the learning assessments were conducted in a medical school. The results from the learning assessments confirm the effectiveness of the VSE for teaching medical residents and students. The scope of the assessment was to ensure (1) the correctness and (2) the usefulness of the VSE. Out of 37 residents/students who participated in the test, 32 showed improvements in their understanding of the LISS plating surgical process. A majority of participants were satisfied with the use of teaching Avatars and haptic technology. A paired t test was conducted to test the statistical significance of the assessment data which showed that the data were statistically significant. This paper demonstrates the usefulness of adopting information centric modeling approach in the design and development of the simulator. The assessment results underscore the potential of using VR-based simulators in medical education especially in orthopedic surgery.

  18. Revival of pure titanium for dynamically loaded porous implants using additive manufacturing.

    PubMed

    Wauthle, Ruben; Ahmadi, Seyed Mohammad; Amin Yavari, Saber; Mulier, Michiel; Zadpoor, Amir Abbas; Weinans, Harrie; Van Humbeeck, Jan; Kruth, Jean-Pierre; Schrooten, Jan

    2015-09-01

    Additive manufacturing techniques are getting more and more established as reliable methods for producing porous metal implants thanks to the almost full geometrical and mechanical control of the designed porous biomaterial. Today, Ti6Al4V ELI is still the most widely used material for porous implants, and none or little interest goes to pure titanium for use in orthopedic or load-bearing implants. Given the special mechanical behavior of cellular structures and the material properties inherent to the additive manufacturing of metals, the aim of this study is to investigate the properties of selective laser melted pure unalloyed titanium porous structures. Therefore, the static and dynamic compressive properties of pure titanium structures are determined and compared to previously reported results for identical structures made from Ti6Al4V ELI and tantalum. The results show that porous Ti6Al4V ELI still remains the strongest material for statically loaded applications, whereas pure titanium has a mechanical behavior similar to tantalum and is the material of choice for cyclically loaded porous implants. These findings are considered to be important for future implant developments since it announces a potential revival of the use of pure titanium for additively manufactured porous implants. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Intraoperative culture positive allograft bone and subsequent postoperative infections: a retrospective review.

    PubMed

    Sims, Laura; Kulyk, Paul; Woo, Allan

    2017-04-01

    Obtaining intraoperative cultures of allograft bone just before use in orthopedic procedures is standard practice in many centres; however, the association between positive cultures and subsequent surgical infections is unknown. Our study had 3 goals: to determine the prevalence of positive intraoperative allograft culture and subsequent infection; to determine if, in cases of subsequent infection, organisms isolated at reoperation were the same as those cultured from the allograft at the time of the index procedure; and to assess the costs associated with performing intraoperative allograft cultures. In this retrospective case series, we obtained data on patients receiving allograft bone between 2009 and 2012. Patients receiving allograft with positive cultures were reviewed to identify cases of significant infection. Organisms isolated at reoperation were compared with the allograft culture taken at the time of implantation, and we performed a cost assessment. Of the 996 allograft bone grafts used, 43 (4.3%) had positive intraoperative cultures and significant postoperative infections developed in 2, requiring reoperation. Antibiotics based on culture results were prescribed in 24% of cases. Organisms cultured at the time of reoperation differed from those isolated initially. The cost of performing 996 allograft cultures was $169 320. This series suggests that rates of positive intraoperative bone allograft culture are low, and subsequent infection is rare. In cases of postoperative infection, primary allograft culture and secondary tissue cultures isolated different organisms. Costs associated with performing cultures are high. Eliminating initial culture testing could save $42 500 per year in our health region.

  20. Intraoperative culture positive allograft bone and subsequent postoperative infections: a retrospective review

    PubMed Central

    Sims, Laura; Kulyk, Paul; Woo, Allan

    2017-01-01

    Background Obtaining intraoperative cultures of allograft bone just before use in orthopedic procedures is standard practice in many centres; however, the association between positive cultures and subsequent surgical infections is unknown. Our study had 3 goals: to determine the prevalence of positive intraoperative allograft culture and subsequent infection; to determine if, in cases of subsequent infection, organisms isolated at reoperation were the same as those cultured from the allograft at the time of the index procedure; and to assess the costs associated with performing intraoperative allograft cultures. Methods In this retrospective case series, we obtained data on patients receiving allograft bone between 2009 and 2012. Patients receiving allograft with positive cultures were reviewed to identify cases of significant infection. Organisms isolated at reoperation were compared with the allograft culture taken at the time of implantation, and we performed a cost assessment. Results Of the 996 allograft bone grafts used, 43 (4.3%) had positive intraoperative cultures and significant postoperative infections developed in 2, requiring reoperation. Antibiotics based on culture results were prescribed in 24% of cases. Organisms cultured at the time of reoperation differed from those isolated initially. The cost of performing 996 allograft cultures was $169 320. Conclusion This series suggests that rates of positive intraoperative bone allograft culture are low, and subsequent infection is rare. In cases of postoperative infection, primary allograft culture and secondary tissue cultures isolated different organisms. Costs associated with performing cultures are high. Eliminating initial culture testing could save $42 500 per year in our health region. PMID:28234217

  1. Improving Response Rates among Students with Orthopedic and Multiple Disabilities

    ERIC Educational Resources Information Center

    Wilkens, Christian P.; Kuntzler, Patrice M.; Cardenas, Shaun; O'Malley, Eileen; Phillips, Carolyn; Singer, Jacqueline; Stoeger, Alex; Kindler, Keith

    2014-01-01

    One challenge teachers of students with orthopedic and multiple disabilities face is providing sufficient time and opportunity to communicate. This challenge is universal across countries, schools, and settings: teachers want students to communicate because communication lies at the core of what makes us human. Yet students with orthopedic and…

  2. Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants.

    PubMed

    Lee, Woo-Taek; Koak, Jai-Young; Lim, Young-Jun; Kim, Seong-Kyun; Kwon, Ho-Beom; Kim, Myung-Joo

    2012-05-01

    The poly-ether-ether-ketone (PEEK) polymer is of great interest as an alternative to titanium in orthopedics because of its biocompatibility and low elastic modulus. This study evaluated the fatigue limits of PEEK and the effects of the low elastic modulus PEEK in relation to existing dental implants. Compressive loading tests were performed with glass fiber-reinforced PEEK (GFR-PEEK), carbon fiber-reinforced PEEK (CFR-PEEK), and titanium rods. Among these tests, GFR-PEEK fatigue tests were performed according to ISO 14801. For the finite element analysis, three-dimensional models of dental implants and bone were constructed. The implants in the test groups were coated with a 0.5-mm thick and 5-mm long PEEK layer on the upper intrabony area. The strain energy densities (SED) were calculated, and the bone resorption was predicted. The fatigue limits of GFR-PEEK were 310 N and were higher than the static compressive strength of GFR-PEEK. The bone around PEEK-coated implants showed higher levels of SED than the bone in direct contact with the implants, and the wider diameter and stiffer implants showed lower levels of SED. The compressive strength of the GFR-PEEK and CFR-PEEK implants ranged within the bite force of the anterior and posterior dentitions, respectively, and the PEEK implants showed adequate fatigue limits for replacing the anterior teeth. Dental implants with PEEK coatings and PEEK implants may reduce stress shielding effects. Dental implant application of PEEK polymer-fatigue limit and stress shielding. Copyright © 2012 Wiley Periodicals, Inc.

  3. Improving surgeon utilization in an orthopedic department using simulation modeling

    PubMed Central

    Simwita, Yusta W; Helgheim, Berit I

    2016-01-01

    Purpose Worldwide more than two billion people lack appropriate access to surgical services due to mismatch between existing human resource and patient demands. Improving utilization of existing workforce capacity can reduce the existing gap between surgical demand and available workforce capacity. In this paper, the authors use discrete event simulation to explore the care process at an orthopedic department. Our main focus is improving utilization of surgeons while minimizing patient wait time. Methods The authors collaborated with orthopedic department personnel to map the current operations of orthopedic care process in order to identify factors that influence poor surgeons utilization and high patient waiting time. The authors used an observational approach to collect data. The developed model was validated by comparing the simulation output with the actual patient data that were collected from the studied orthopedic care process. The authors developed a proposal scenario to show how to improve surgeon utilization. Results The simulation results showed that if ancillary services could be performed before the start of clinic examination services, the orthopedic care process could be highly improved. That is, improved surgeon utilization and reduced patient waiting time. Simulation results demonstrate that with improved surgeon utilizations, up to 55% increase of future demand can be accommodated without patients reaching current waiting time at this clinic, thus, improving patient access to health care services. Conclusion This study shows how simulation modeling can be used to improve health care processes. This study was limited to a single care process; however the findings can be applied to improve other orthopedic care process with similar operational characteristics. PMID:29355193

  4. Antibacterial Surface Treatment for Orthopaedic Implants

    PubMed Central

    Gallo, Jiri; Holinka, Martin; Moucha, Calin S.

    2014-01-01

    It is expected that the projected increased usage of implantable devices in medicine will result in a natural rise in the number of infections related to these cases. Some patients are unable to autonomously prevent formation of biofilm on implant surfaces. Suppression of the local peri-implant immune response is an important contributory factor. Substantial avascular scar tissue encountered during revision joint replacement surgery places these cases at an especially high risk of periprosthetic joint infection. A critical pathogenic event in the process of biofilm formation is bacterial adhesion. Prevention of biomaterial-associated infections should be concurrently focused on at least two targets: inhibition of biofilm formation and minimizing local immune response suppression. Current knowledge of antimicrobial surface treatments suitable for prevention of prosthetic joint infection is reviewed. Several surface treatment modalities have been proposed. Minimizing bacterial adhesion, biofilm formation inhibition, and bactericidal approaches are discussed. The ultimate anti-infective surface should be “smart” and responsive to even the lowest bacterial load. While research in this field is promising, there appears to be a great discrepancy between proposed and clinically implemented strategies, and there is urgent need for translational science focusing on this topic. PMID:25116685

  5. A positive bacterial culture during re-implantation is associated with a poor outcome in two-stage exchange arthroplasty for deep infection.

    PubMed

    Akgün, D; Müller, M; Perka, C; Winkler, T

    2017-11-01

    The aim of this study was to identify the incidence of positive cultures during the second stage of a two-stage revision arthroplasty and to analyse the association between positive cultures and an infection-free outcome. This single-centre retrospective review of prospectively collected data included patients with a periprosthetic joint infection (PJI) of either the hip or the knee between 2013 and 2015, who were treated using a standardised diagnostic and therapeutic algorithm with two-stage exchange. Failure of treatment was assessed according to a definition determined by a Delphi-based consensus. Logistic regression analysis was performed to assess the predictors of positive culture and risk factors for failure. The mean follow-up was 33 months (24 to 48). A total of 163 two-stage revision arthroplasties involving 84 total hip arthroplasties (THAs) and 79 total knee arthroplasties (TKAs) were reviewed. In 27 patients (16.6%), ≥ 1 positive culture was identified at re-implantation and eight (29.6%) of these subsequently failed compared with 20 (14.7%) patients who were culture-negative. The same initially infecting organism was isolated at re-implantation in nine of 27 patients (33.3%). The organism causing re-infection in none of the patients was the same as that isolated at re-implantation. The risk of the failure of treatment was significantly higher in patients with a positive culture (odds ratio (OR) 1.7; 95% confidence interval (CI) 1.0 to 3.0; p = 0.049) and in patients with a higher Charlson Comorbidity Index (OR 1.5; 95% CI 1.6 to 1.8; p = 0.001). Positive culture at re-implantation was independently associated with subsequent failure. Surgeons need to be aware of this association and should consider the medical optimisation of patients with severe comorbidities both before and during treatment. Cite this article: Bone Joint J 2017;99-B:1490-5. ©2017 The British Editorial Society of Bone & Joint Surgery.

  6. Saquinavir-mediated inhibition of human immunodeficiency virus (HIV) infection in SCID mice implanted with human fetal thymus and liver tissue: an in vivo model for evaluating the effect of drug therapy on HIV infection in lymphoid tissues.

    PubMed Central

    Pettoello-Mantovani, M; Kollmann, T R; Raker, C; Kim, A; Yurasov, S; Tudor, R; Wiltshire, H; Goldstein, H

    1997-01-01

    Treatment with protease inhibitors alone or in combination with inhibitors of reverse transcriptase potently suppresses levels of human immunodeficiency virus (HIV) RNA in plasma and thereby may significantly delay the progression of HIV-mediated disease. To investigate the effect of treatment with the protease inhibitor saquinavir on HIV replication in the lymphoid tissues, we used a SCID-hu mouse model that we developed, in which human thymic and liver tissues (hu-thy/liv) were implanted under both kidney capsules in SCID mice (thy/liv-SCID-hu mice). These mice are populated in the periphery with large numbers of human T cells and develop disseminated HIV infection after intraimplant injection. thy/liv-SCID-hu mice with established HIV infection that were treated for 1 month with saquinavir had a significantly lower viral load present in the implanted hu-thy/liv and mouse spleen than did the untreated HIV-infected thy/liv-SCID-hu mice. To examine the capacity of acute treatment with saquinavir to prevent HIV infection, some thy/liv-SCID-hu mice were inoculated with HIV and then immediately started on saquinavir. Although treated mice had markedly lower viral loads in the thy/liv implants and spleens, HIV infection was not completely prevented. Thus, the effect of antiviral therapy on HIV infection in the major site of HIV replication, the lymphoid tissues, can be readily evaluated in our thy/liv-SCID-hu mice. These mice should prove to be a useful model for determining the in vivo effectiveness of different therapeutic interventions on acute and chronic HIV infection. PMID:9303378

  7. Surface Modifications of Titanium Implants by Multilayer Bioactive Coatings with Drug Delivery Potential: Antimicrobial, Biological, and Drug Release Studies

    NASA Astrophysics Data System (ADS)

    Ordikhani, Farideh; Zustiak, Silviya Petrova; Simchi, Abdolreza

    2016-04-01

    Recent strategies to locally deliver antimicrobial agents to combat implant-associated infections—one of the most common complications in orthopedic surgery—are gaining interest. However, achieving a controlled release profile over a desired time frame remains a challenge. In this study, we present an innovative multifactorial approach to combat infections which comprises a multilayer chitosan/bioactive glass/vancomycin nanocomposite coating with an osteoblastic potential and a drug delivery capacity. The bioactive drug-eluting coating was prepared on the surface of titanium foils by a multistep electrophoretic deposition technique. The adopted deposition strategy allowed for a high antibiotic loading of 1038.4 ± 40.2 µg/cm2. The nanocomposite coating exhibited a suppressed burst release with a prolonged sustained vancomycin release for up to 6 weeks. Importantly, the drug release profile was linear with respect to time, indicating a zero-order release kinetics. An in vitro bactericidal assay against Staphylococcus aureus confirmed that releasing the drug reduced the risk of bacterial infection. Excellent biocompatibility of the developed coating was also demonstrated by in vitro cell studies with a model MG-63 osteoblast cell line.

  8. Orthopedic surgery postgraduate year 1 intern curriculum improves initial orthopedic in-training examination performance.

    PubMed

    Roberts, Craig S; Nyland, John; Broome, Brandon

    2012-04-01

    To determine the efficacy of an educational curriculum designed for orthopedic surgery postgraduate year 1 (PGY-1) interns to improve initial Orthopedic In-Training Examination (OITE) performance. A retrospective cohort study was performed that evaluated the PGY-1 intern OITE performance of one residency training program (n = 55) during 7-year periods before (1996-2002) and after structured curriculum implementation (2003-2009). Linear regression analysis revealed insignificant changes in median PGY-1 intern OITE percentile rank during the precurriculum period (R = 0.08, P = 0.53). Postcurriculum period comparisons revealed significantly improving PGY-1 intern OITE percentile rank (R = 0.46, P = 0.048). Pre- and postcurriculum median US Medical Licensing Examination (USMLE) Step I scores did not display statistically significant differences (218.2 ± 6.6 vs 229.1 ± 13.8, Mann-Whitney U test, z = -1.5, P = 0.10). Spearman rho correlations revealed a moderate relation (r = 0.61) between postcurriculum PGY-1 intern OITE percentile rank and USMLE Step I score, but not during the precurriculum period. A moderate relation (r = 0.50) also was observed between postcurriculum USMLE Step I score and average OITE percentile rank during the 5-year residency program, but not during the precurriculum period. PGY-1 intern OITE percentile rank improved significantly with the addition of a specially designed educational curriculum. The stronger USMLE Step I score and PGY-1 intern OITE percentile rank relation observed during the postcurriculum period suggests that interns who participated in the educational curriculum were better prepared to translate general medical and patient care knowledge into orthopedic surgery knowledge.

  9. Attempted salvage of infected cardiovascular implantable electronic devices: Are there clinical factors that predict success?

    PubMed

    Peacock, James E; Stafford, Jeanette M; Le, Katherine; Sohail, Muhammad Rizwan; Baddour, Larry M; Prutkin, Jordan M; Danik, Stephan B; Vikram, Holenarasipur R; Hernandez-Meneses, Marta; Miró, José M; Blank, Elisabeth; Naber, Christoph K; Carrillo, Roger G; Greenspon, Arnold J; Tseng, Chi-Hong; Uslan, Daniel Z

    2018-03-08

    Published guidelines mandate complete device removal in cases of cardiovascular implantable electronic device (CIED) infection. Clinical predictors of successful salvage of infected CIEDs have not been defined. Data from the Multicenter Electrophysiologic Device Infection Collaboration, a prospective, observational, multinational cohort study of CIED infection, were used to investigate whether clinical predictors of successful salvage of infected devices could be identified. Of 433 adult patients with CIED infections, 306 (71%) underwent immediate device explantation. Medical management with device retention and antimicrobial therapy was initially attempted in 127 patients (29%). "Early failure" of attempted salvage occurred in 74 patients (58%) who subsequently underwent device explantation during the index hospitalization. The remaining 53 patients (42%) in the attempted salvage group retained their CIED. Twenty-six (49%) had resolution of CIED infection (successful salvage group) whereas 27 patients (51%) experienced "late" salvage failure. Upon comparing the salvage failure group, early and late (N = 101), to the group experiencing successful salvage of an infected CIED (N = 26), no clinical or laboratory predictors of successful salvage were identified. However, by univariate analysis, coagulase-negative staphylococci as infecting pathogens (P = 0.0439) and the presence of a lead vegetation (P = 0.024) were associated with overall failed salvage. In patients with definite CIED infections, clinical and laboratory variables cannot predict successful device salvage. Until new data are forthcoming, device explantation should remain a mandatory and early management intervention in patients with CIED infection in keeping with existing expert guidelines unless medical contraindications exist or patients refuse device removal. © 2018 Wiley Periodicals, Inc.

  10. Evolving trauma and orthopedics training in the UK.

    PubMed

    Inaparthy, Praveen K; Sayana, Murali K; Maffulli, Nicola

    2013-01-01

    The ever-growing population of the UK has resulted in increasing demands on its healthcare service. Changes have been introduced in the UK medical training system to avoid loss of training time and make it more focused and productive. Modernizing medical careers (MMC) was introduced in 2005. This promised to reduce the training period for a safe trauma specialist, in trauma and orthopedics, to 10 years. At around the same time, the European Working Time Directive (EWTD) was introduced to reduce the working hours for junior doctors in training, to improve patient safety and also work-life balance of junior doctors. Introduction of the assessment tools from Orthopedic Competency assessment project (OCAP) will help tailor the training according to the needs of the trainee. The aim of this article is to review the changes in the UK orthopedic surgical training over the past two decades. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  11. The Economic Burden of Orthopedic Surgery Residency Interviews on Applicants.

    PubMed

    Fogel, Harold A; Finkler, Elissa S; Wu, Karen; Schiff, Adam P; Nystrom, Lukas M

    2016-01-01

    The intense competition for orthopedic surgery residency positions influences the interview process. The financial impact on residency applicants is less well understood. The purpose of the present study was to define the economic burden of the orthopedic surgery residency interview process while additionally describing how applicants finance the expense. We distributed surveys to 48 nonrotating applicants at our institution's residency interview days for the 2015 match year. The survey consisted of eleven questions specific to the costs of interviewing for orthopedic surgery residency positions. The survey response rate was 90% (43/48). Applicants applied to a median of 65 orthopedic surgery residency programs (range 21-88) and targeted a median of 15 interviews (range 12-25). The mean cost estimate for a single interview was $450 (range $200-800) and the cost estimate for all interviews was $7,119 (range $2,500-15,000). Applicants spent a mean of $344 (range $0-750) traveling to our interview. Seventy-two percent borrowed money to finance their interview costs and 28% canceled interviews for financial reasons. The financial cost of interviewing for orthopedic surgery is substantial and a majority of applicants add to their educational debt by taking out loans to finance interviews. Future considerations should be made to minimize these costs for an already financially burdened population.

  12. The Economic Burden of Orthopedic Surgery Residency Interviews on Applicants

    PubMed Central

    Fogel, Harold A.; Finkler, Elissa S.; Wu, Karen; Schiff, Adam P.; Nystrom, Lukas M.

    2016-01-01

    Background The intense competition for orthopedic surgery residency positions influences the interview process. The financial impact on residency applicants is less well understood. The purpose of the present study was to define the economic burden of the orthopedic surgery residency interview process while additionally describing how applicants finance the expense. Methods We distributed surveys to 48 nonrotating applicants at our institution’s residency interview days for the 2015 match year. The survey consisted of eleven questions specific to the costs of interviewing for orthopedic surgery residency positions. Results The survey response rate was 90% (43/48). Applicants applied to a median of 65 orthopedic surgery residency programs (range 21-88) and targeted a median of 15 interviews (range 12-25). The mean cost estimate for a single interview was $450 (range $200-800) and the cost estimate for all interviews was $7,119 (range $2,500-15,000). Applicants spent a mean of $344 (range $0-750) traveling to our interview. Seventy-two percent borrowed money to finance their interview costs and 28% canceled interviews for financial reasons. Conclusions The financial cost of interviewing for orthopedic surgery is substantial and a majority of applicants add to their educational debt by taking out loans to finance interviews. Future considerations should be made to minimize these costs for an already financially burdened population. PMID:27528831

  13. Reducing the effect of parasitic capacitance on implantable passive resonant sensors.

    PubMed

    Drazan, John F; Abdoun, Omar T; Wassick, Michael T; Marcus, George A; Dahle, Reena; Beardslee, Luke A; Cady, Nathaniel C; Ledet, Eric H

    2016-08-01

    Passive, LC resonators have the potential to serve as small, robust, low cost, implantable sensors to wirelessly monitor implants following orthopedic surgery. One significant barrier to using LC sensors is the influence on the sensor's resonance of the surrounding conductive high permittivity media in vivo. The surrounding media can detune the resonant frequency of the LC sensor resulting in a bias. To mitigate the effects of the surrounding media, we added a "capping layer" to LC sensors to isolate them from the surrounding media. Several capping materials and thicknesses were tested to determine effectiveness at reducing the sensor's interaction with the surrounding media. Results show that a 1 mm glass capping layer on the outer surfaces of the sensor was sufficient to reduce the effects of the media on sensor signal to less than 1%.

  14. Clinical characteristics and outcome of infective endocarditis involving implantable cardiac devices.

    PubMed

    Athan, Eugene; Chu, Vivian H; Tattevin, Pierre; Selton-Suty, Christine; Jones, Phillip; Naber, Christoph; Miró, José M; Ninot, Salvador; Fernández-Hidalgo, Nuria; Durante-Mangoni, Emanuele; Spelman, Denis; Hoen, Bruno; Lejko-Zupanc, Tatjana; Cecchi, Enrico; Thuny, Franck; Hannan, Margaret M; Pappas, Paul; Henry, Margaret; Fowler, Vance G; Crowley, Anna Lisa; Wang, Andrew

    2012-04-25

    Infection of implantable cardiac devices is an emerging disease with significant morbidity, mortality, and health care costs. To describe the clinical characteristics and outcome of cardiac device infective endocarditis (CDIE) with attention to its health care association and to evaluate the association between device removal during index hospitalization and outcome. Prospective cohort study using data from the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), conducted June 2000 through August 2006 in 61 centers in 28 countries. Patients were hospitalized adults with definite endocarditis as defined by modified Duke endocarditis criteria. In-hospital and 1-year mortality. CDIE was diagnosed in 177 (6.4% [95% CI, 5.5%-7.4%]) of a total cohort of 2760 patients with definite infective endocarditis. The clinical profile of CDIE included advanced patient age (median, 71.2 years [interquartile range, 59.8-77.6]); causation by staphylococci (62 [35.0% {95% CI, 28.0%-42.5%}] Staphylococcus aureus and 56 [31.6% {95% CI, 24.9%-39.0%}] coagulase-negative staphylococci); and a high prevalence of health care-associated infection (81 [45.8% {95% CI, 38.3%-53.4%}]). There was coexisting valve involvement in 66 (37.3% [95% CI, 30.2%-44.9%]) patients, predominantly tricuspid valve infection (43/177 [24.3%]), with associated higher mortality. In-hospital and 1-year mortality rates were 14.7% (26/177 [95% CI, 9.8%-20.8%]) and 23.2% (41/177 [95% CI, 17.2%-30.1%]), respectively. Proportional hazards regression analysis showed a survival benefit at 1 year for device removal during the initial hospitalization (28/141 patients [19.9%] who underwent device removal during the index hospitalization had died at 1 year, vs 13/34 [38.2%] who did not undergo device removal; hazard ratio, 0.42 [95% CI, 0.22-0.82]). Among patients with CDIE, the rate of concomitant valve infection is high, as is mortality, particularly if there is valve involvement. Early device

  15. Asymptomatic urinary tract infection: Cause of postoperative wound infection.

    PubMed

    Ashraf, Irfan; Umer, Masood

    2014-12-01

    To determine the rate of urinary tract infection in patients given incomplete treatment before undergoing hip fracture surgery. The descriptive case series was conducted at Aga Khan University Hospital, Karachi, From October 25, 2012 to April 24, 2013. 84 postmenopausal women having hip fracture along with asymptomatic urinary tract infection. The infection was treated incompletely and postoperatively wound infection rate was determined. The SPSS version 17 was used to analyze the data. The overall mean age of the 84 patients in the study was 63.57+10.34 years. Overall, 14(16.7%) patients had wound infection after orthopaedic implant surgery for hip fracture. There was a high occurrence of wound infection after hip implant surgery in patients having preoperative asymptomatic urinary tract infection who were treated incompletely.

  16. Incidence, Causes, and Impact of In-Hospital Infections After Transcatheter Aortic Valve Implantation.

    PubMed

    Tirado-Conte, Gabriela; Freitas-Ferraz, Afonso B; Nombela-Franco, Luis; Jimenez-Quevedo, Pilar; Biagioni, Corina; Cuadrado, Ana; Nuñez-Gil, Ivan; Salinas, Pablo; Gonzalo, Nieves; Ferrera, Carlos; Vivas, David; Higueras, Javier; Viana-Tejedor, Ana; Perez-Vizcayno, Maria Jose; Vilacosta, Isidre; Escaned, Javier; Fernandez-Ortiz, Antonio; Macaya, Carlos

    2016-08-01

    In-hospital infections (IHI) are one of the most common and serious problems after invasive procedures. Transcatheter aortic valve implantation (TAVI) is an increasingly used alternative to surgery in patients with severe symptomatic aortic stenosis. The aim of this study was to determine the incidence, origin, risk factors, and clinical outcomes of IHI after TAVI. A total of 303 consecutive patients with severe aortic stenosis who underwent transfemoral TAVI were included and followed during a median time of 21 months. We examined the occurrence, types, origin, and timing of infections during hospital stay as well as short- and long-term clinical outcomes according to the occurrence of IHI. A total of 51 patients (17%; 62 infectious episodes) experienced IHI after TAVI. Respiratory and urinary tract infections were the most frequent type of infections (44% and 34%, respectively), followed by surgical site infection (8%) and bloodstream infection (5%). Positive cultures were obtained in 74% of the samples, of which 65% were gram-negative bacilli. Modifiable factors such as bleeding (p = 0.005) and length of coronary care unit stay (p <0.001) were independently associated with an increased infection risk. Patients with IHI had a longer hospital stay (14 vs 6 days, p <0.001), an increased mortality (hazard ratio 2.48, 95% CI 1.45 to 4.23) and readmission rate (hazard ratio 2.0, 95% CI 1.27 to 3.14) during the follow-up. In conclusion, IHI is a frequent complication after TAVI with a significant impact on short- and long-term clinical outcomes. The most important risk factors associated with the development of this complication were modifiable periprocedural aspects. These results underline the importance to implement specific preventive strategies to reduce in-hospital-acquired infections after TAVI. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Is Salvage of Recently Infected Breast Implant After Breast Augmentation or Reconstruction Possible? An Experimental Study.

    PubMed

    Castus, P; Heymans, O; Melin, P; Renwart, L; Henrist, C; Hayton, E; Mordon, S; Leclère, F M

    2018-04-01

    The reinsertion of an infected implant when peri-prosthetic infection occurs early after breast augmentation or breast reconstruction remains controversial. In this experimental study, the authors tried to remove bacteria, and their biofilm, from the colonized surface of breast prostheses, without damaging their integrity. A total of 112 shell samples of silicone breast prostheses, smooth (SPSS) and textured (TPSS), were colonized by S. epidermidis (SE) or S. aureus (SA) strains, all able to produce biofilms. After 15 days, all the samples were removed from the contaminated culture broth and constituted 4 groups of 20 contaminated samples: SPSS/SE (group I), SPSS/SA (group II), TPSS/SE (group III), TPSS/SE (group IV). In another group-group SEM-, 16 colonized samples were used for documentation with scanning electron microscopy (SEM). The remaining 16 samples were used to test the limits of detection of the sterility test. All samples of groups I-IV and 8 samples of group SEM were « washed » with a smooth brush in a povidone-iodine bath and rinsed with saline solution. A subset of the washed samples was sent for SEM and the others were immersed in sterile broth and were incubated at 35 °C for 3 weeks (groups I-IV). Fifteen days after contamination, all the samples in groups I-IV were colonized. In the SEM group, SEM images attested to the presence of bacteria in biofilm attached to the shells. After cleaning, SEM did not reveal any bacteria and there was no visible alteration in the outer structure of the shell. Sterility tests performed after decontamination in groups I-IV remained negative for all the samples. Breast prostheses recently contaminated with Staphylococci, frequently involved in peri-prosthetic breast implant infection and capable of producing biofilms, can be efficiently decontaminated by the procedure used in this study. Our decontamination procedure did not alter the surface structure of the prostheses. This decontamination procedure

  18. A qualitative and quantitative needs assessment of pain management for hospitalized orthopedic patients.

    PubMed

    Cordts, Grace A; Grant, Marian S; Brandt, Lynsey E; Mears, Simon C

    2011-08-08

    Despite advances in pain management, little formal teaching is given to practitioners and nurses in its use for postoperative orthopedic patients. The goal of our study was to determine the educational needs for orthopedic pain management of our residents, nurses, and physical therapists using a quantitative and qualitative assessment. The needs analysis was conducted in a 10-bed orthopedic unit at a teaching hospital and included a survey given to 20 orthopedic residents, 9 nurses, and 6 physical therapists, followed by focus groups addressing barriers to pain control and knowledge of pain management. Key challenges for nurses included not always having breakthrough pain medication orders and the gap in pain management between cessation of patient-controlled analgesia and ordering and administering oral medications. Key challenges for orthopedic residents included treating pain in patients with a history of substance abuse, assessing pain, and determining when to use long-acting vs short-acting opioids. Focus group assessments revealed a lack of training in pain management and the need for better coordination of care between nurses and practitioners and improved education about special needs groups (the elderly and those with substance abuse issues). This needs assessment showed that orthopedic residents and nurses receive little formal education on pain management, despite having to address pain on a daily basis. This information will be used to develop an educational program to improve pain management for postoperative orthopedic patients. An integrated educational program with orthopedic residents, nurses, and physical therapists would promote understanding of issues for each discipline. Copyright 2011, SLACK Incorporated.

  19. Proximal spinal muscular atrophy: current orthopedic perspective

    PubMed Central

    Haaker, Gerrit; Fujak, Albert

    2013-01-01

    Spinal muscular atrophy (SMA) is a hereditary neuromuscular disease of lower motor neurons that is caused by a defective “survival motor neuron” (SMN) protein that is mainly associated with proximal progressive muscle weakness and atrophy. Although SMA involves a wide range of disease severity and a high mortality and morbidity rate, recent advances in multidisciplinary supportive care have enhanced quality of life and life expectancy. Active research for possible treatment options has become possible since the disease-causing gene defect was identified in 1995. Nevertheless, a causal therapy is not available at present, and therapeutic management of SMA remains challenging; the prolonged survival is increasing, especially orthopedic, respiratory and nutritive problems. This review focuses on orthopedic management of the disease, with discussion of key aspects that include scoliosis, muscular contractures, hip joint disorders, fractures, technical devices, and a comparative approach of conservative and surgical treatment. Also emphasized are associated complications including respiratory involvement, perioperative care and anesthesia, nutrition problems, and rehabilitation. The SMA disease course can be greatly improved with adequate therapy with established orthopedic procedures in a multidisciplinary therapeutic approach. PMID:24399883

  20. New diagnostic pathways urgently needed. Protocol of PET Guidance I pilot study: positron emission tomography in suspected cardiac implantable electronic device-related infection.

    PubMed

    Marciniak-Emmons, Marta Barbara; Sterliński, Maciej; Syska, Paweł; Maciąg, Aleksander; Farkowski, Michał Mirosław; Firek, Bohdan; Dziuk, Mirosław; Zając, Dariusz; Pytkowski, Mariusz; Szwed, Hanna

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection is a complication of increasing incidence. We present a protocol of an observational case control clinical trial "Positron Emission Tomography Combined With Computed Tomography (PET CT) in Suspected Cardiac Implantable Electronic Device Infection, a Pilot Study - PET Guidance I" (NCT02196753). The aim of this observational clinical trial is to assess and standardise diagnostic algorithms for CIED infections (lead-dependent infective endocarditis, generator pocket infection, fever of unknown origin) with PET CT in Poland. Study group will consist of 20 patients with initial diagnosis of CIED-related infection paired with a control group of 20 patients with implanted CIEDs, who underwent PET CT due to other non-infectious indications and have no data for infectious process in follow-up. All patients included in the study will undergo standard diagnostic pro-cess. Conventional/standard diagnostic and therapeutic process will consist of: medical interview, physical examination, laboratory tests, blood cultures; imaging studies: echocardiography: transthoracic (TTE), and, if there are no contraindications transoesophageal, computed tomography scan for pulmonary embolism if indicated; if there are abnormalities in other systems, decisions concerning further diagnostics will be made at the physician's discretion. As well as standard diagnostic procedures, patients will undergo whole body PET CT scan to localise infection or inflammation. Diagnosis and therapeutic decision will be obtained from the Study Committee. Follow-up will be held within six months with control visits at three and six months. During each follow-up visit, all patients will undergo laboratory tests, two blood cultures collected 1 h apart, and TTE. In case of actual clinical suspicion of infective endocarditis or local generator pocket infection, patients will be referred for further diagnostics. Endpoints for the results assessment

  1. Accuracy of estimating Unicondylar Knee Replacement implant varus/valgus angles from antero-posterior radiographs.

    PubMed

    Khare, Rahul; Jaramaz, Branislav

    2016-12-01

    Unicondylar Knee Replacement (UKR) is an orthopedic surgical procedure to reduce pain and improve function in the knee. Load-bearing long-standing antero-posterior (AP) radiographs are typically used postoperatively to measure the leg alignment and assess the varus/valgus implant orientation. However, implant out-of-plane rotations, user variability, and X-ray acquisition parameters introduce errors in the estimation of the implant varus/valgus estimation. Previous work has explored the accuracy of various imaging modalities in this estimation. In this work, we explored the impact of out-of-plane rotations and X-ray acquisition parameters on the estimation of implant component varus/valgus angles. For our study, we used a single CT scan and positioned femoral and tibial implants under varying orientations within the CT volume. Then, a custom software application was used to obtain digitally reconstructed radiographs from the CT scan with implants under varying orientations. Two users were then asked to manually estimate the varus/valgus angles for the implants. We found that there was significant inter-user variability (p < 0.05) in the varus/valgus estimates for the two users. However, the 'ideal' measurements, obtained using actual implant orientations, showed small errors due to variations in implant orientation. We also found that variation in the projection center does not have a statistically significant impact (p < 0.01) on the estimation of implant varus/valgus angles. We conclude that manual estimates of UKR implant varus/valgus orientations are unreliable.

  2. Gram-negative prosthetic joint infection: outcome of a debridement, antibiotics and implant retention approach. A large multicentre study.

    PubMed

    Rodríguez-Pardo, D; Pigrau, C; Lora-Tamayo, J; Soriano, A; del Toro, M D; Cobo, J; Palomino, J; Euba, G; Riera, M; Sánchez-Somolinos, M; Benito, N; Fernández-Sampedro, M; Sorli, L; Guio, L; Iribarren, J A; Baraia-Etxaburu, J M; Ramos, A; Bahamonde, A; Flores-Sánchez, X; Corona, P S; Ariza, J

    2014-11-01

    We aim to evaluate the epidemiology and outcome of gram-negative prosthetic joint infection (GN-PJI) treated with debridement, antibiotics and implant retention (DAIR), identify factors predictive of failure, and determine the impact of ciprofloxacin use on prognosis. We performed a retrospective, multicentre, observational study of GN-PJI diagnosed from 2003 through to 2010 in 16 Spanish hospitals. We define failure as persistence or reappearance of the inflammatory joint signs during follow-up, leading to unplanned surgery or repeat debridement>30 days from the index surgery related death, or suppressive antimicrobial therapy. Parameters predicting failure were analysed with a Cox regression model. A total of 242 patients (33% men; median age 76 years, interquartile range (IQR) 68-81) with 242 episodes of GN-PJI were studied. The implants included 150 (62%) hip, 85 (35%) knee, five (2%) shoulder and two (1%) elbow prostheses. There were 189 (78%) acute infections. Causative microorganisms were Enterobacteriaceae in 78%, Pseudomonas spp. in 20%, and other gram-negative bacilli in 2%. Overall, 19% of isolates were ciprofloxacin resistant. DAIR was used in 174 (72%) cases, with an overall success rate of 68%, which increased to 79% after a median of 25 months' follow-up in ciprofloxacin-susceptible GN-PJIs treated with ciprofloxacin. Ciprofloxacin treatment exhibited an independent protective effect (adjusted hazard ratio (aHR) 0.23; 95% CI, 0.13-0.40; p<0.001), whereas chronic renal impairment predicted failure (aHR, 2.56; 95% CI, 1.14-5.77; p 0.0232). Our results confirm a 79% success rate in ciprofloxacin-susceptible GN-PJI treated with debridement, ciprofloxacin and implant retention. New therapeutic strategies are needed for ciprofloxacin-resistant PJI. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  3. Desktop-based computer-assisted orthopedic training system for spinal surgery.

    PubMed

    Rambani, Rohit; Ward, James; Viant, Warren

    2014-01-01

    Simulation and surgical training has moved on since its inception during the end of the last century. The trainees are getting more exposed to computers and laboratory training in different subspecialties. More needs to be done in orthopedic simulation in spinal surgery. To develop a training system for pedicle screw fixation and validate its effectiveness in a cohort of junior orthopedic trainees. Fully simulated computer-navigated training system is used to train junior orthopedic trainees perform pedicle screw insertion in the lumbar spine. Real patient computed tomography scans are used to produce the real-time fluoroscopic images of the lumbar spine. The training system was developed to simulate pedicle screw insertion in the lumbar spine. A total of 12 orthopedic senior house officers performed pedicle screw insertion in the lumbar spine before and after the training on training system. The results were assessed based on the scoring system, which included the amount of time taken, accuracy of pedicle screw insertion, and the number of exposures requested to complete the procedure. The result shows a significant improvement in amount of time taken, accuracy of fixation, and the number of exposures after the training on simulator system. This was statistically significant using paired Student t test (p < 0.05). Fully simulated computer-navigated training system is an efficient training tool for young orthopedic trainees. This system can be used to augment training in the operating room, and trainees acquire their skills in the comfort of their study room or in the training room in the hospital. The system has the potential to be used in various other orthopedic procedures for learning of technical skills in a manner aimed at ensuring a smooth escalation in task complexity leading to the better performance of procedures in the operating theater. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  4. Assessment of a press-fit proximal femoral modular reconstruction implant (PFMR®) at 14.5 years. A 48-case series with a disturbing rate of implant fracture.

    PubMed

    Dumoulin, Q; Sabau, S; Goetzmann, T; Jacquot, A; Sirveaux, F; Mole, D; Roche, O

    2018-05-01

    The PFMR ® proximal femoral modular reconstruction implant (Protek, Sulzer Orthopedics, Switzerland) is a straight modular stem in sanded titanium with press-fit anchorage, intended to achieve spontaneous bone reconstruction following Wagner's principle. The aim of the present study was to analyze long-term clinical and radiological outcome. A single-center retrospective study included 48 PFMR stems implanted in 47 patients between 1998 and 2002. Results in this series were previously reported at 7 years' follow-up. Clinical assessment used PMA and Harris scores. Radiologic assessment focused on stem stability and osseointegration, and bone stock following Le Béguec. Twenty-three patients were seen at a mean 14.5 years' follow-up (13 deceased, 11 lost to follow-up), including 1 with bilateral implants, i.e., 24 stems. PMA and Harris scores, stem stability and osseointegration and bone stock were stable with respect to the 7-year findings. Radiology found 7 stem fractures in the Morse taper, i.e., in 29% of implants. Two of these cases required femoral implant replacement; 5 were asymptomatic. Long-term outcome for PFMR stems was clinically and radiologically satisfactory for the 16 patients free of mechanical complications. The Morse taper fracture rate was high, and higher than reported elsewhere. The usual risk factors for implant fracture were not found in the present series. The modular design of the press-fit revision implant is its weak point; monoblock implants should be used in patients with good life-expectancy. IV (retrospective study). Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. Treatment of peri-implant diseases: a review of the literature and protocol proposal.

    PubMed

    Armas, Joshé; Culshaw, Shauna; Savarrio, Lee

    2013-01-01

    Over 100,000 implants were placed in the UK in 2010. As the numbers of patients with implant-retained prostheses increases, operators are encountering an increasing number of biological implant complications, most commonly peri-implant mucositis and peri-implantitis. The effective management of these complications is crucial to maintain patients' oral health. In particular, in contrast to common periodontal infections, some peri-implant infections may benefit from surgical intervention as a first line approach. This article reviews the literature on the treatment options for peri-implant mucositis and peri-implantitis and proposes a protocol for their treatment.

  6. Bioactivity of plasma implanted biomaterials

    NASA Astrophysics Data System (ADS)

    Chu, Paul K.

    2006-01-01

    Plasma immersion ion implantation and deposition (PIII&D) is an effective technique to enhance the surface bioactivity of materials. In this paper, recent progress made in our laboratory on plasma surface modification of biomedical materials is described. NiTi alloys have unique super-elastic and shape memory properties and are suitable for orthopedic implants but the leaching of toxic Ni may pose health hazards in humans. We have recently investigated the use of acetylene, oxygen and nitrogen PIII&D to prevent out-diffusion of nickel and good results have been obtained. Silicon is the most important material in the microelectronics industry but its surface biocompatibility has not been investigated in details. We have recently performed hydrogen PIII into silicon to improve the surface bioactivity and observed biomimetic growth of apatite on the surface in simulated body fluids. Diamond-like carbon (DLC) is widely used in the industry due to its excellent mechanical properties and chemical inertness and by incorporation of elements such as nitrogen and phosphorus, the surface blood compatibility can be improved. The properties as well as in vitro biological test results are discussed in this article.

  7. Computer-assisted navigation in orthopedic surgery.

    PubMed

    Mavrogenis, Andreas F; Savvidou, Olga D; Mimidis, George; Papanastasiou, John; Koulalis, Dimitrios; Demertzis, Nikolaos; Papagelopoulos, Panayiotis J

    2013-08-01

    Computer-assisted navigation has a role in some orthopedic procedures. It allows the surgeons to obtain real-time feedback and offers the potential to decrease intra-operative errors and optimize the surgical result. Computer-assisted navigation systems can be active or passive. Active navigation systems can either perform surgical tasks or prohibit the surgeon from moving past a predefined zone. Passive navigation systems provide intraoperative information, which is displayed on a monitor, but the surgeon is free to make any decisions he or she deems necessary. This article reviews the available types of computer-assisted navigation, summarizes the clinical applications and reviews the results of related series using navigation, and informs surgeons of the disadvantages and pitfalls of computer-assisted navigation in orthopedic surgery. Copyright 2013, SLACK Incorporated.

  8. Influence of copper composition on mechanical properties of biodegradable material Mg-Zn-Cu for orthopedic application

    NASA Astrophysics Data System (ADS)

    Purniawan, A.; Maulidiah, H. M.; Purwaningsih, H.

    2018-04-01

    Implant is usually used as a treatment of bone fracture. At the moment, non-biodegradable implants is still widely employed in this application. Non-biodegradable implant requires re-surgery to retrieve implants that are installed in the body. It increase the cost and it is painful for the patient itself. In order to solve the problem, Mg-based biodegradable metals is developing so that the material will be compatible with body and gradually degrade in patient's body. However, magnesium has several disadvantages such as high degradation rates and low mechanical properties when compared to the mechanical properties of natural bone. Therefore, it is necessary to add elements into the magnesium alloy. In this research, copper (Cu) was alloyed in Mg alloy based biodegradable material. In addition, Cu is not only strengthening the structure but also for supporting element for the immune system, antibacterial and antifungal. The purpose of this research is to improve mechanical properties of Mg-based biodegradable material using Cu alloying. Powder metallurgy method was used to fabricate the device. The variation used in this research is the composition of Cu (0.5, 1, and 1.5% Cu). The porosity test was performed using apparent porosity test, compressive test and hardness test to know the mechanical properties of the alloy, and the weightless test to find out the material degradation rate. Based on the results can be conclude that Mg-Zn-Cu alloy material with 1% Cu composition is the most suitable specimen to be applied as a candidate for orthopedic devices material with hardness value is 393.6 MPa. Also obtained the value of the compressive test is 153 MPa.

  9. Vancomycin-modified implant surface inhibits biofilm formation and supports bone-healing in an infected osteotomy model in sheep: a proof-of-concept study.

    PubMed

    Stewart, Suzanne; Barr, Stephanie; Engiles, Julie; Hickok, Noreen J; Shapiro, Irving M; Richardson, Dean W; Parvizi, Javad; Schaer, Thomas P

    2012-08-01

    Implant-associated infections contribute to patient morbidity and health care costs. We hypothesized that surface modification of titanium fracture hardware with vancomycin would support bone-healing and prevent bacterial colonization of the implant in a large-animal model. A unilateral transverse mid-diaphyseal tibial osteotomy was performed and repaired with a titanium locking compression plate in nine sheep. Four control animals were treated with an unmodified plate and five experimental animals were treated with a vancomycin-modified plate. The osteotomy was inoculated with 2.5 × 106 colony-forming units of Staphylococcus aureus. The animals were killed at three months postoperatively, and implants were retrieved aseptically. Microbiologic and histologic analyses, scanning electron and confocal microscopy, and microcomputed tomography were performed. All animals completed the study. Compared with the treatment cohort, control animals exhibited protracted lameness in the operatively treated leg. Gross findings during necropsy were consistent with an infected osteotomy accompanied by a florid and lytic callus. Microcomputed tomography and histologic analysis of the tibiae further supported the presence of septic osteomyelitis in the control cohort. Thick biofilms were also evident, and bacterial cultures were positive for Staphylococcus aureus in three of four control animals. In contrast, animals treated with vancomycin-treated plates exhibited a healed osteotomy site with homogenous remodeling, there was no evidence of biofilm formation on the retrieved plate, and bacterial cultures from only one of five animals were positive for Staphylococcus aureus. Vancomycin-derivatized plate surfaces inhibited implant colonization with Staphylococcus aureus and supported bone-healing in an infected large-animal model.

  10. Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study.

    PubMed

    Lee, Cheng-Hung; Shih, Cheng-Min; Huang, Kui-Chou; Chen, Kun-Hui; Hung, Li-Kun; Su, Kuo-Chih

    2016-11-01

    Clinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18 mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young's modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  11. First described case of prosthetic joint infection with Clostridium disporicum.

    PubMed

    McBride, Joseph A; Sterkel, Alana K; Rehrauer, William M; Smith, Jeannina A

    2017-12-01

    An orthopedic hardware infection with Clostridium disporicum is described. C. disporicum is a gram positive anaerobic bacillus which can contain two subterminal spores. C. disporicum had not previously been reported in musculoskeletal infections. Gram stains demonstrating gram positive bacilli with two subterminal spores should alert practitioners to the possibility of C. disporicum infection. Published by Elsevier Ltd.

  12. The Diagnosis of Periprosthetic Infection

    PubMed Central

    del Arco, Alfonso; Bertrand, María Luisa

    2013-01-01

    Periprosthetic infection (PJI) is the most serious joint replacement complication, occurring in 0.8-1.9% of knee arthroplasties and 0.3-1.7% of hip arthroplasties. A definition of PJI was proposed in the November 2011 issue of the journal Clinical Orthopedics and Related Research. The presence of a fistula or of local inflammatory signs is indicative of PJI, but in many cases local pain is the only symptom. In the absence of underlying inflammatory conditions, C-reactive protein measurement is the most useful preoperative blood test for detecting infection associated with a prosthetic joint. The most useful preoperative diagnostic test is the aspiration of synovial joint fluid to obtain a total and differential cell count and culture. Intraoperative frozen sections of periprosthetic tissues produce excellent accuracy in predicting a diagnosis of PJI but only moderate accuracy in ruling out the diagnosis. In this process, obtaining a quality sample is the first step, and determines the quality of microbiological results. Specimens for culture should be obtained prior to the initiation of antibiotic treatment. Sonication of a removed implant may increase the culture yield. Plain radiography has low sensitivity and low specificity for detecting infection associated with a prosthetic joint. Computed tomography and magnetic resonance imaging may be useful in the evaluation of complex cases, but metal inserts interfere with these tests, and abnormalities may be non-specific. Labelled-leucocyte imaging (e.g., leucocytes labelled with indium-111) combined with bone marrow imaging with the use of technetium-99m–labelled sulphur colloid is considered the imaging test of choice when imaging is necessary. PMID:23898349

  13. Synergistic effects of bisphosphonate and calcium phosphate nanoparticles on peri-implant bone responses in osteoporotic rats.

    PubMed

    Alghamdi, Hamdan S; Bosco, Ruggero; Both, Sanne K; Iafisco, Michele; Leeuwenburgh, Sander C G; Jansen, John A; van den Beucken, Jeroen J J P

    2014-07-01

    The prevalence of osteoporosis will increase within the next decades due to the aging world population, which can affect the bone healing response to dental and orthopedic implants. Consequently, local drug targeting of peri-implant bone has been proposed as a strategy for the enhancement of bone-implant integration in osteoporotic conditions. In the present study, an established in-vivo femoral condyle implantation model in osteoporotic and healthy bone is used to analyze the osteogenic capacity of titanium implants coated with bisphosphonate (BP)-loaded calcium phosphate nanoparticles (nCaP) under compromised medical conditions. After 4 weeks of implantation, peri-implant bone volume (%BV; by μCT) and bone area (%BA; by histomorphometry) were significantly increased within a distance of 500 μm from implant surfaces functionalized with BP compared to control implants in osteoporotic and healthy conditions. Interestingly, the deposition of nCaP/BP coatings onto implant surfaces increased both peri-implant bone contact (%BIC) and volume (%BV) compared to the deposition of nCaP or BP coatings individually, in osteoporotic and healthy conditions. The results of real-time PCR revealed similar osteogenic gene expression levels to all implant surfaces at 4-weeks post-implantation. In conclusion, simultaneous targeting of bone formation (by nCaP) and bone resorption (by BP) using nCaP/BP surface coatings represents an effective strategy for synergistically improvement of bone-implant integration, especially in osteoporotic conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. [Daily routine in orthopedics and traumatology - results of a nationwide survey of residents].

    PubMed

    Merschin, D; Münzberg, M; Stange, R; Schüttrumpf, J P; Perl, M; Mutschler, M

    2014-10-01

    The subject orthopedics and traumatology suffers by a loss of attractiveness which results in a lack of young blood. The aim of this study of the Youth Forum of the German Society of Orthopedics and Traumatology (DGOU) is to register the working conditions of residents in orthopedics. In the months September and October 2013 we performed a survey on members of the following German societies: German Society of Orthopedics and Traumatology (DGOU), German Society of Traumatology (DGU) and the German Society of Orthopedics and Orthopedic Surgery (DGOOC), (age < 40). Our questionnaire includes 15 questions. We achieved 28,9 % (n = 331) answered questionnaires. The mean working time per week is 55 hours. 73 % of all participants do more than 5 emergency services per month. 52 % are more than 3 times on duty for 24 hours. Only 13 % of all residents have well ordered working hours. Normally working time is divided into three parts: one third for bureaucracy, one for operation theatre and the last for other activities (e.g. ward round). 35,6 % do only one surgery per week, 12 % do not perform any surgeries. An annual report is performed only in 45 %. A structured concept of training only exists in 16 % of all hospitals. In addition to clinical work 45 % are involved in scientific projects, mostly in their spare-time. Finally 58 % of all surgeons would still recommend orthopedics and traumatology. In order to maintain orthopedics and traumatology as an attractive it is necessary to implement flexible working time models and to reorganize and improve training-concepts. Georg Thieme Verlag KG Stuttgart · New York.

  15. Ambulatory surgery in orthopedics: experience of over 10,000 patients.

    PubMed

    Martín-Ferrero, M A; Faour-Martín, O; Simon-Perez, C; Pérez-Herrero, M; de Pedro-Moro, J A

    2014-03-01

    The concept of day surgery is becoming an increasingly important part of elective surgery worldwide. Relentless pressure to cut costs may constrain clinical judgment regarding the most appropriate location for a patient's surgical care. The aim of this study was to determine clinical and quality indicators relating to our experience in orthopedic day durgery, mainly in relation to unplanned overnight admission and readmission rates. Additionally, we focused on describing the main characteristics of the patients that experienced complications, and compared the patient satisfaction rates following ambulatory and non-ambulatory procedures. We evaluated 10,032 patients who underwent surgical orthopedic procedures according to the protocols of our Ambulatory Surgery Unit. All complications that occurred were noted. A quality-of-life assessment (SF-36 test) was carried out both pre- and postoperatively. Ambulatory substitution rates and quality indicators for orthopedic procedures were also determined. The major complication rate was minimal, with no mortal cases, and there was a high rate of ambulatory substitution for the procedures studied. Outcomes of the SF-36 questionnaire showed significant improvement postoperatively. An unplanned overnight admission rate of 0.14 % was achieved. Our institution has shown that it is possible to provide good-quality ambulatory orthopedic surgery. There still appears to be the potential to increase the proportion of these procedures. Surgeons and anesthesiologists must strongly adhere to strict patient selection criteria for ambulatory orthopedic surgery in order to reduce complications in the immediate postoperative term.

  16. Pathogenic Mechanisms and Host Interactions in Staphylococcus epidermidis Device-Related Infection.

    PubMed

    Sabaté Brescó, Marina; Harris, Llinos G; Thompson, Keith; Stanic, Barbara; Morgenstern, Mario; O'Mahony, Liam; Richards, R Geoff; Moriarty, T Fintan

    2017-01-01

    Staphylococcus epidermidis is a permanent member of the normal human microbiota, commonly found on skin and mucous membranes. By adhering to tissue surface moieties of the host via specific adhesins, S. epidermidis is capable of establishing a lifelong commensal relationship with humans that begins early in life. In its role as a commensal organism, S. epidermidis is thought to provide benefits to human host, including out-competing more virulent pathogens. However, largely due to its capacity to form biofilm on implanted foreign bodies, S. epidermidis has emerged as an important opportunistic pathogen in patients receiving medical devices. S. epidermidis causes approximately 20% of all orthopedic device-related infections (ODRIs), increasing up to 50% in late-developing infections. Despite this prevalence, it remains underrepresented in the scientific literature, in particular lagging behind the study of the S. aureus . This review aims to provide an overview of the interactions of S. epidermidis with the human host, both as a commensal and as a pathogen. The mechanisms retained by S. epidermidis that enable colonization of human skin as well as invasive infection, will be described, with a particular focus upon biofilm formation. The host immune responses to these infections are also described, including how S. epidermidis seems to trigger low levels of pro-inflammatory cytokines and high levels of interleukin-10, which may contribute to the sub-acute and persistent nature often associated with these infections. The adaptive immune response to S. epidermidis remains poorly described, and represents an area which may provide significant new discoveries in the coming years.

  17. Level of evidence gap in orthopedic research.

    PubMed

    Baldwin, Keith D; Bernstein, Joseph; Ahn, Jaimo; McKay, Scott D; Sankar, Wudbhav N

    2012-09-01

    Level of evidence is the most widely used metric for the quality of a publication, but instances exist in which a Level I study is neither feasible nor desirable. The goal of this study was to evaluate the level of evidence gap in current orthopedic research, which the authors defined as the disparity between the level of evidence that would be required to optimally answer the primary research question and the level of evidence that was actually used. Five orthopedic surgeons (K.D.B., J.B., J.A., S.D.M., W.N.S.) evaluated blinded articles from the first 6 months of 2010 in the Journal of Bone and Joint Surgery (American Volume) (JBJS-Am), classifying the study type and design and extracting a primary research question from each article. Each evaluator then defined the study type and method, along with the level of evidence that would ideally be used to address the primary research question. The level of evidence gap was then calculated by subtracting the actual level of evidence of the manuscript from the level of evidence of the idealized study. Of the 64 JBJS-Am manuscripts eligible for analysis, the average level of evidence was between Level II and III (mean, 2.73). The average level of evidence gap was 1.06 compared with the JBJS-Am-designated level of evidence and 1.28 compared with the evaluators' assessment. Because not all questions require Level I studies, level of evidence alone may not be the best metric for the quality of orthopedic surgery literature. Instead, the authors' concept of a level of evidence gap may be a better tool for assessing the state of orthopedic research publications. Copyright 2012, SLACK Incorporated.

  18. Rational design of nanofiber scaffolds for orthopedic tissue repair and regeneration

    PubMed Central

    Ma, Bing; Xie, Jingwei; Jiang, Jiang; Shuler, Franklin D; Bartlett, David E

    2013-01-01

    This article reviews recent significant advances in the design of nanofiber scaffolds for orthopedic tissue repair and regeneration. It begins with a brief introduction on the limitations of current approaches for orthopedic tissue repair and regeneration. It then illustrates that rationally designed scaffolds made up of electrospun nanofibers could be a promising solution to overcome the problems that current approaches encounter. The article also discusses the intriguing properties of electrospun nanofibers, including control of composition, structures, orders, alignments and mechanical properties, use as carriers for topical drug and/or gene sustained delivery, and serving as substrates for the regulation of cell behaviors, which could benefit musculoskeletal tissue repair and regeneration. It further highlights a few of the many recent applications of electrospun nanofiber scaffolds in repairing and regenerating various orthopedic tissues. Finally, the article concludes with perspectives on the challenges and future directions for better design, fabrication and utilization of nanofiber scaffolds for orthopedic tissue engineering. PMID:23987110

  19. Global research coaching in orthopedic surgery: seeding for an international network

    PubMed Central

    Ferreira, Ana Paula Bonilauri; Rajgor, Dimple; Shah, Jatin; Shah, Anand; Pietrobon, Ricardo

    2012-01-01

    Despite the importance of delivering evidence-based health care, orthopedic surgeons have directed fewer efforts towards the generation of such evidence. Even when present, published evidence lacks methodological rigor and is known to be inaccurate. One of the main reasons for the lack of generation of quality evidence, and the low involvement in research among orthopedic surgeons, is the lack of structured research coaching environments where they can learn concepts and hone their research skills. There is a palpable need for a pragmatic and outcome-oriented approach that can equip orthopedic surgeons with effective ways of communicating their research in writing. We describe a pragmatic research coaching program, designed and developed by the Research on Research group, which aims to build a global network of orthopedic researchers trained in streamlined and standardized research methods. We also provide a brief overview of the course principles and tools, and the platforms used in this program. PMID:24453591

  20. Port type is a possible risk factor for implantable venous access port-related bloodstream infections and no sign of local infection predicts the growth of gram-negative bacilli.

    PubMed

    Hsu, Jui-Feng; Chang, Hsu-Liang; Tsai, Ming-Ju; Tsai, Ying-Ming; Lee, Yen-Lung; Chen, Pei-Huan; Fan, Wen-Chieh; Su, Yu-Chung; Yang, Chih-Jen

    2015-09-30

    Implantable venous access port (IVAP)-related blood stream infections (BSIs) are one of the most common complications of implantable venous ports. The risk factors and pathogens for IVAP-related BSIs are still controversial. We retrospectively reviewed all patients who received IVAPs at a Hospital in Taiwan from January 1, 2011 to June 31, 2014. Two types of venous port, BardPort® 6.6 fr (Bard port) and Autosuture Chemosite® 7.5 fr (TYCO port) were used. All patients with clinically proven venous port-related BSIs were enrolled. A total of 552 patients were enrolled. There were 34 episodes of IVAP-related BSIs during the study period for a total incidence of 0.177 events/1000 catheter days. Port type (TYCO vs. Bard, HR = 7.105 (95% confidence interval (CI), 1.688-29.904), p = 0.0075), age > 65 years (HR = 2.320 (95 % CI, 1.179-4.564), p = 0.0148), and lung cancer (HR = 5.807 (95% CI, 2.946-11.447), p < 0.001) were risk factors for port infections. We also found that no local sign of infection was significantly associated with the growth of gram-negative bacilli (p = 0.031). TYCO venous ports, age > 65 years, and lung cancer were all significant risk factors for IVAP-related BSIs, and no sign of infection was significantly associated with the growth of gram-negative bacilli.

  1. What opportunities are available for resident involvement in national orthopedic and subspecialty societies?

    PubMed

    Dy, Christopher J; Cross, Michael B; Osbahr, Daryl C; Parks, Michael L; Green, Daniel W

    2011-10-05

    As physician involvement in health policy grows, there will be an increasing need for future leaders in orthopedics. Interested orthopedic residents may be unaware of opportunities for leadership involvement in professional and subspecialty organizations. This article investigates whether national and subspecialty organizations offer membership to residents, allow residents to participate in committees, and provide opportunities for scholarly activity and mentorship. The authors surveyed 20 national orthopedic professional and subspecialty societies to evaluate the availability and cost of resident membership, meeting attendance and participation, research funding, committee membership, and mentorship opportunities. Each society's Web site was reviewed, and societies were contacted by phone if further inquiry was needed. Of the 20 orthopedic societies surveyed, 11 allowed resident membership. Five of 20 societies allowed residents to serve on committees, with a total of 14 total positions for residents. Four organizations provided formalized mentorship programs to residents. Although opportunities for resident involvement in subspecialty and professional societies are available in the majority of groups surveyed, the Orthopaedic Trauma Association and American Society for Surgery of the Hand provided the most comprehensive collection of opportunities. Residents should also pursue involvement in other organizations that may be more readily accessible, such as local, state, and regional orthopedic and medical societies. Increased resident participation in these organizations may help in increasing the 14 nationally available committee positions for orthopedic residents. Our orthopedic profession and societies should encourage motivated residents to pursue involvement and leadership at the national level. Copyright 2011, SLACK Incorporated.

  2. Economic analysis of two-stage septic revision after total hip arthroplasty: What are the relevant costs for the hospital's orthopedic department?

    PubMed

    Kasch, R; Assmann, G; Merk, S; Barz, T; Melloh, M; Hofer, A; Merk, H; Flessa, S

    2016-03-01

    The number of septic total hip arthroplasty (THA) revisions is increasing continuously, placing a growing financial burden on hospitals. Orthopedic departments performing septic THA revisions have no basis for decision making regarding resource allocation as the costs of this procedure for the departments are unknown. It is widely assumed that septic THA procedures can only be performed at a loss for the department. Therefore, the purpose of this study was to investigate whether this assumption is true by performing a detailed analysis of the costs and revenues for two-stage septic THA revision. Patients who underwent revision THA for septic loosening in two sessions from January 2009 through March 2012 were included in this retrospective, consecutive cost study from the orthopedic department's point of view. We analyzed variable and case-fixed costs for septic revision THA with special regard to implantation and explantation stay. By using marginal costing approach we neglected hospital-fixed costs. Outcome measures include reimbursement and daily contribution margins. The average direct costs (reimbursement) incurred for septic two-stage revision THA was €10,828 (€24,201). The difference in cost and contribution margins per day was significant (p < .001 and p = 0.019) for ex- and implantation (€4147 vs. €6680 and €429 vs. €306) while length of stay and reimbursement were comparable. This is the first detailed analysis of the hospital department's cost for septic revision THA performed in two sessions. Disregarding hospital-fixed costs the included variable and case fixed-costs were covered by revenues. This study provides cost data, which will be guidance for health care decision makers.

  3. Low sensitivity of implant sonication when screening for infection in revision surgery

    PubMed Central

    Van Diek, Floor M; Albers, Christiaan G M; Van Hooff, Miranda L; Meis, Jacques F; Goosen, Jon H M

    2017-01-01

    Background and purpose Prosthetic-joint infection (PJI) is the most serious complication of arthroplasty, and accurate identification of a potentially responsible microorganism is essential for successful antibiotic treatment. We therefore determined the diagnostic accuracy of sonication and compared it with tissue culture as a screening tool in detecting prosthetic joint infection in revision arthroplasty. Patients and methods 252 consecutive revision arthroplasty cases were enrolled. These cases were determined as being suspected or unsuspected of having infection according to standard criteria. Perioperatively, 6 periprosthetic interface tissue biopsies were obtained from each patient and the implants removed were sonicated. The sensitivity and specificity of periprosthetic tissue culture and sonication fluid cultures were determined. Results Preoperatively, 75 revision cases were classified as having PJI (33 early and 42 late) and 177 were unsuspected of having infection. Compared with tissue culture, the sensitivity of the sonication fluid analysis was low: 0.47 (95% CI: 0.35–0.59) for sonication as compared to 0.68 (95% CI: 0.56–0.78) for tissue culture. The specificity of the sonication fluid analysis was higher than that for tissue culture: 0.99 (95% CI: 0.96–1.0) as compared to 0.80 (95% CI: 0.74–0.86). Interpretation Sonication is a highly specific test for diagnosis of PJI. However, due to the low sensitivity, a negative sonication result does not rule out the presence of PJI. Thus, sonication is not of value for screening of microorganisms during revision surgery. PMID:28287012

  4. Cost drivers in total hip arthroplasty: effects of procedure volume and implant selling price.

    PubMed

    Kelly, Michael P; Bozic, Kevin J

    2009-01-01

    Total hip arthroplasty (THA), though a highly effective procedure for patients with end-stage hip disease, has become increasingly costly, both because of increasing procedure volume and because of the introduction and widespread use of new technologies. Data regarding procedure volume and procedure costs for THA were obtained from the National Inpatient Sample and other published sources for the years 1995 through 2005. Procedure volume increased 61% over the period studied. When adjusted for inflation, using the medical consumer price index, the average selling price of THA implants increased 24%. The selling price of THA implants as a percentage of total procedure costs increased from 29% to 60% during the period under study. The increasing cost of THA in the United States is a result of both increased procedure volume and increased cost of THA implants. No long-term outcome studies related to use of new implant technologies are available, and short-term results have been similar to those obtained with previous generations of THA implants. This study reinforces the need for a US total joint arthroplasty registry and for careful clinical and economic analyses of new technologies in orthopedics.

  5. The incidence and causative organisms of infection in elective shoulder surgery.

    PubMed

    Mayne, Alistair I W; Bidwai, Amit S; Clifford, Rachael; Smith, Matthew G; Guisasola, Inigo; Brownson, Peter

    2018-07-01

    Deep infection remains a serious complication of orthopaedic surgery. Knowledge of infection rates and causative organisms is important to guide infection control measures. The aim of the present study was to determine infection rates and causative organisms in elective shoulder surgery. Cases complicated by infection were identified and prospectively recorded over a 2-year period. All patients undergoing elective shoulder surgery in the concurrent period at a single Specialist Upper Limb Unit in the UK were identified from the hospital electronic database. In total, 1574 elective shoulder cases were performed: 1359 arthroscopic (540 with implant insertion) and 215 open (197 with implant insertion). The overall infection rate in open surgery of 2.5% was significantly higher than arthroscopic implant cases at 0.7% ( p  < 0.005). The overall infection rate in implant arthroscopic surgery was significantly higher at 0.7% compared to 0% in non-implant related surgery. ( p  < 0.05). Patients undergoing open shoulder surgery have a significantly higher risk of infection compared to arthroscopic shoulder surgery. Arthroscopic surgery with implant insertion has a statistically significantly higher risk of developing deep infection compared to procedures with no implant insertion. We recommend prophylactic antibiotics in open shoulder surgery and arthroscopic shoulder surgery with implant insertion.

  6. Antimicrobial surfaces for craniofacial implants: state of the art.

    PubMed

    Actis, Lisa; Gaviria, Laura; Guda, Teja; Ong, Joo L

    2013-04-01

    In an attempt to regain function and aesthetics in the craniofacial region, different biomaterials, including titanium, hydroxyapatite, biodegradable polymers and composites, have been widely used as a result of the loss of craniofacial bone. Although these materials presented favorable success rates, osseointegration and antibacterial properties are often hard to achieve. Although bone-implant interactions are highly dependent on the implant's surface characteristics, infections following traumatic craniofacial injuries are common. As such, poor osseointegration and infections are two of the many causes of implant failure. Further, as increasingly complex dental repairs are attempted, the likelihood of infection in these implants has also been on the rise. For these reasons, the treatment of craniofacial bone defects and dental repairs for long-term success remains a challenge. Various approaches to reduce the rate of infection and improve osseointegration have been investigated. Furthermore, recent and planned tissue engineering developments are aimed at improving the implants' physical and biological properties by improving their surfaces in order to develop craniofacial bone substitutes that will restore, maintain and improve tissue function. In this review, the commonly used biomaterials for craniofacial bone restoration and dental repair, as well as surface modification techniques, antibacterial surfaces and coatings are discussed.

  7. A Comprehensive, High-Quality Orthopedic Intern Surgical Skills Program.

    PubMed

    Ford, Samuel E; Patt, Joshua C; Scannell, Brian P

    2016-01-01

    To design and implement a month-long, low-cost, comprehensive surgical skills curriculum built to address the needs of orthopedic surgery interns with high satisfaction among both interns and faculty. The study design was retrospective and descriptive. The study was conducted at tertiary care referral center with a medium sized orthopedic residency surgery program (5 residents/year). Totally 5 orthopedic surgery residents and 16 orthopedic surgery faculty participated. A general mission was established-to orient the resident to the postgraduate year 1 and prepare them for success in residency. The basic tenets of the American Board of Orthopaedic Surgeons surgical skills program framework were built. Curricular additions included anatomic study, surgical approaches, joint-specific physical examination, radiographic interpretation, preoperative planning, reduction techniques, basic emergency and operating room procedures, cadaveric procedure practice, and introduction to arthroplasty. The program was held in August during protected time for intern participants. In total, 16 orthopedic surgeons instructed 85% of the educational sessions. One faculty member did most of the preparation and organization to facilitate the program. The program ran for a cumulative 89 hours, including 14.5 hours working with cadaveric specimens. The program cost a total of $8100. The average module received a 4.15 rating on a 5-point scale, with 4 representing "good" and 5 representing "excellent." The program was appropriately timed and addressed topics relevant to the intern without sacrificing clinical experience or burdening inpatient services with interns' absence. The program received high satisfaction ratings from both the interns as well as the faculty. Additionally, the program fostered early relationships between interns and faculty-an unforeseen benefit. In the future, our program plans to better integrate validated learning metrics and improve instruction pertaining to both

  8. Value Added: the Case for Point-of-View Camera use in Orthopedic Surgical Education.

    PubMed

    Karam, Matthew D; Thomas, Geb W; Taylor, Leah; Liu, Xiaoxing; Anthony, Chris A; Anderson, Donald D

    2016-01-01

    Orthopedic surgical education is evolving as educators search for new ways to enhance surgical skills training. Orthopedic educators should seek new methods and technologies to augment and add value to real-time orthopedic surgical experience. This paper describes a protocol whereby we have started to capture and evaluate specific orthopedic milestone procedures with a GoPro® point-of-view video camera and a dedicated video reviewing website as a way of supplementing the current paradigm in surgical skills training. We report our experience regarding the details and feasibility of this protocol. Upon identification of a patient undergoing surgical fixation of a hip or ankle fracture, an orthopedic resident places a GoPro® point-of-view camera on his or her forehead. All fluoroscopic images acquired during the case are saved and later incorporated into a video on the reviewing website. Surgical videos are uploaded to a secure server and are accessible for later review and assessment via a custom-built website. An electronic survey of resident participants was performed utilizing Qualtrics software. Results are reported using descriptive statistics. A total of 51 surgical videos involving 23 different residents have been captured to date. This includes 20 intertrochanteric hip fracture cases and 31 ankle fracture cases. The average duration of each surgical video was 1 hour and 16 minutes (range 40 minutes to 2 hours and 19 minutes). Of 24 orthopedic resident surgeons surveyed, 88% thought capturing a video portfolio of orthopedic milestones would benefit their education. There is a growing demand in orthopedic surgical education to extract more value from each surgical experience. While further work in development and refinement of such assessments is necessary, we feel that intraoperative video, particularly when captured and presented in a non-threatening, user friendly manner, can add significant value to the present and future paradigm of orthopedic surgical

  9. Automated implantable cardioverter defibrillator lead infection in a patient with previous superior vena cava thrombosis.

    PubMed

    Connelly, Tara; Siddiqui, Sadiq; Kolcow, Walenty; Veerasingam, Dave

    2015-11-04

    We present a case of a 44-year-old woman who presented with cough, pleuritic chest pain and fever leading to a diagnosis of pneumonia±pulmonary embolism. She had a history of familial hypertrophic obstructive cardiomyopathy (HOCM), for which an automated implantable cardioverter defibrillator (AICD) had been implanted, and a subsequent superior vena cava (SVC) thrombus, for which she was anticoagulated with warfarin. On admission, blood cultures grew a coagulase-negative Staphylococcus. CT pulmonary angiogram and transoesophageal echocardiography (TOE) were performed and revealed large vegetations adherent to the AICD leads with complete occlusion of the SVC. The infected leads were the source of sepsis. Open surgery was planned. For cardiopulmonary bypass, the venous cannula was inserted in the inferior vena cava (IVC) and a completely bloodless field was obtained in the right atrium allowing for the extraction of the AICD leads completely, along with the adherent vegetations from within. 2015 BMJ Publishing Group Ltd.

  10. Alloplastic implants for orbital wall reconstruction.

    PubMed

    Jacono, A A; Moskowitz, B

    2000-01-01

    Nonabsorbable alloplastic implants for orbital wall reconstruction have been widely accepted by surgeons because of their ready availability, stability, and biocompatability. Many complications have arisen with this class of implants because the lack of host tissue integration allows for implant migration, implant extrusion, recurrent hemorrhage, and infection. Porous polyethylene implants provide a welcome alternative as they have the unique properly of supporting tissue ingrowth in vivo. Their semirigid structure provides structural stability when used around the orbit, and their malleability allows for easy contouring. This paper presents our surgical approach to reconstructing orbital defects with porous polyethylene implants, including orbital floor, and superior, medial, and lateral wall defects, and discusses the advantages/disadvantages of other nonabsorbable alloplasts.

  11. Neutrophil-derived MRP-14 is up-regulated in infectious osteomyelitis and stimulates osteoclast generation.

    PubMed

    Dapunt, Ulrike; Giese, Thomas; Maurer, Susanne; Stegmaier, Sabine; Prior, Birgit; Hänsch, G Maria; Gaida, Matthias M

    2015-10-01

    Bone infections of patients with joint replacement by endoprosthesis (so called "periprosthetic joint infection") pose a severe problem in the field of orthopedic surgery. The diagnosis is often difficult, and treatment is, in most cases, complicated and prolonged. Patients often require an implant exchange surgery, as the persistent infection and the accompanying inflammation lead to tissue damage with bone degradation and consequently, to a loosening of the implant. To gain insight into the local inflammatory process, expression of the proinflammatory cytokine MRP-14, a major content of neutrophils, and its link to subsequent bone degradation was evaluated. We found MRP-14 prominently expressed in the affected tissue of patients with implant-associated infection, in close association with the chemokine CXCL8 and a dense infiltrate of neutrophils and macrophages. In addition, the number of MRP-14-positive cells correlated with the presence of bone-resorbing osteoclasts. MRP-14 plasma concentrations were significantly higher in patients with implant-associated infection compared with patients with sterile inflammation or healthy individuals, advocating MRP-14 as a novel diagnostic marker. A further biologic activity of MRP-14 was detected: rMRP-14 directly induced the differentiation of monocytes to osteoclasts, thus linking the inflammatory response in implant infections with osteoclast generation, bone degradation, and implant loosening. © Society for Leukocyte Biology.

  12. Fiber glass-bioactive glass composite for bone replacing and bone anchoring implants.

    PubMed

    Vallittu, Pekka K; Närhi, Timo O; Hupa, Leena

    2015-04-01

    Although metal implants have successfully been used for decades, devices made out of metals do not meet all clinical requirements, for example, metal objects may interfere with some new medical imaging systems, while their stiffness also differs from natural bone and may cause stress-shielding and over-loading of bone. Peer-review articles and other scientific literature were reviewed for providing up-dated information how fiber-reinforced composites and bioactive glass can be utilized in implantology. There has been a lot of development in the field of composite material research, which has focused to a large extent on biodegradable composites. However, it has become evident that biostable composites may also have several clinical benefits. Fiber reinforced composites containing bioactive glasses are relatively new types of biomaterials in the field of implantology. Biostable glass fibers are responsible for the load-bearing capacity of the implant, while the dissolution of the bioactive glass particles supports bone bonding and provides antimicrobial properties for the implant. These kinds of combination materials have been used clinically in cranioplasty implants and they have been investigated also as oral and orthopedic implants. The present knowledge suggests that by combining glass fiber-reinforced composite with particles of bioactive glass can be used in cranial implants and that the combination of materials may have potential use also as other types of bone replacing and repairing implants. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Patient Attitudes Toward Orthopedic Surgeon Ownership of Related Ancillary Businesses.

    PubMed

    Yi, Paul H; Cross, Michael B; Johnson, Staci R; Rasinski, Kenneth A; Nunley, Ryan M; Della Valle, Craig J

    2016-08-01

    Physician ownership of businesses related to orthopedic surgery, such as surgery centers, has been criticized as potentially leading to misuse of health care resources. The purpose of this study was to determine patients' attitudes toward surgeon ownership of orthopedic-related businesses. We surveyed 280 consecutive patients at 2 centers regarding their attitudes toward surgeon ownership of orthopedic-related businesses using an anonymous questionnaire. Three surgeon ownership scenarios were presented: (1) owning a surgery center, (2) physical therapy (PT), and (3) imaging facilities (eg, Magnetic Resonance Imaging scanner). Two hundred fourteen patients (76%) completed the questionnaire. The majority agreed that it is ethical for a surgeon to own a surgery center (73%), PT practice (77%), or imaging facility (77%). Most (>67%) indicated that their surgeon owning such a business would have no effect on the trust they have in their surgeon. Although >70% agreed that a surgeon in all 3 scenarios would make the same treatment decisions, many agreed that such surgeons might perform more surgery (47%), refer more patients to PT (61%), or order more imaging (58%). Patients favored surgeon autonomy, however, believing that surgeons should be allowed to own such businesses (78%). Eighty-five percent agreed that patients should be informed if their surgeon owns an orthopedic-related business. Although patients express concern over and desire disclosure of surgeon ownership of orthopedic-related businesses, the majority believes that it is an ethical practice and feel comfortable receiving care at such a facility. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Antibiotic prophylaxis for surgical site infections as a risk factor for infection with Clostridium difficile.

    PubMed

    Balch, Aubrey; Wendelboe, Aaron M; Vesely, Sara K; Bratzler, Dale W

    2017-01-01

    We aimed to measure the association between 2013 guideline concordant prophylactic antibiotic use prior to surgery and infection with Clostridium difficile. We conducted a retrospective case-control study by selecting patients who underwent a surgical procedure between January 1, 2012 and December 31, 2013. Large urban community hospital. Cases and controls were patients age 18+ years who underwent an eligible surgery (i.e., colorectal, neurosurgery, vascular/cardiac/thoracic, hysterectomy, abdominal/pelvic and orthopedic surgical procedures) within six months prior to infection diagnosis. Cases were diagnosed with C. difficile infection while controls were not. The primary exposure was receiving (vs. not receiving) the recommended prophylactic antibiotic regimen, based on type and duration. Potential confounders included age, sex, length of hospital stay, comorbidities, type of surgery, and prior antibiotic use. Crude and adjusted odds ratios (OR) and 95% confidence intervals (CI) were calculated using logistic regression. We enrolled 68 cases and 220 controls. The adjusted OR among surgical patients between developing C. difficile infection and not receiving the recommended prophylactic antibiotic regimen (usually receiving antimicrobial prophylaxis for more than 24 hours) was 6.7 (95% CI: 2.9-15.5). Independent risk factors for developing C. difficile infection included having severe comorbidities, receiving antibiotics within the previous 6 months, and undergoing orthopedic surgery. Adherence to the recommended prophylactic antibiotics among surgical patients likely reduces the probability of being case of C. difficile. Antibiotic stewardship should be a priority in strategies to decrease the morbidity, mortality, and costs associated with C. difficile infection.

  15. Antibiotic prophylaxis for surgical site infections as a risk factor for infection with Clostridium difficile

    PubMed Central

    Balch, Aubrey; Vesely, Sara K.; Bratzler, Dale W.

    2017-01-01

    Objective We aimed to measure the association between 2013 guideline concordant prophylactic antibiotic use prior to surgery and infection with Clostridium difficile. Design We conducted a retrospective case-control study by selecting patients who underwent a surgical procedure between January 1, 2012 and December 31, 2013. Setting Large urban community hospital. Patients Cases and controls were patients age 18+ years who underwent an eligible surgery (i.e., colorectal, neurosurgery, vascular/cardiac/thoracic, hysterectomy, abdominal/pelvic and orthopedic surgical procedures) within six months prior to infection diagnosis. Cases were diagnosed with C. difficile infection while controls were not. Methods The primary exposure was receiving (vs. not receiving) the recommended prophylactic antibiotic regimen, based on type and duration. Potential confounders included age, sex, length of hospital stay, comorbidities, type of surgery, and prior antibiotic use. Crude and adjusted odds ratios (OR) and 95% confidence intervals (CI) were calculated using logistic regression. Results We enrolled 68 cases and 220 controls. The adjusted OR among surgical patients between developing C. difficile infection and not receiving the recommended prophylactic antibiotic regimen (usually receiving antimicrobial prophylaxis for more than 24 hours) was 6.7 (95% CI: 2.9–15.5). Independent risk factors for developing C. difficile infection included having severe comorbidities, receiving antibiotics within the previous 6 months, and undergoing orthopedic surgery. Conclusions Adherence to the recommended prophylactic antibiotics among surgical patients likely reduces the probability of being case of C. difficile. Antibiotic stewardship should be a priority in strategies to decrease the morbidity, mortality, and costs associated with C. difficile infection. PMID:28622340

  16. Antibiotic-loaded plaster of Paris implants coated with poly lactide-co-glycolide as a controlled release delivery system for the treatment of bone infections.

    PubMed

    Benoit, M A; Mousset, B; Delloye, C; Bouillet, R; Gillard, J

    1997-01-01

    Plaster of Paris implants containing vancomycin (60 mg/g of carrier) were prepared in order to be used as local delivery system for the treatment of bone infections. The regulation of the release rate was performed by coating the carrier with a polylactide-co-glycolide polymer composed by 10% (w/w) polyglycolic acid and 90% (w/w) racemic poly (D,L-lactic acid). The release of the antibiotic from the biodegradable matrix was evaluated in vitro. From this investigation, it is clear that the drug elution depends on the coating depth. After a burst effect occurring on the first day of the experiment, therapeutic concentrations were measured during one week when uncoated implants were used. The coating allowed decrease of the burst effect and extended efficient release to more than five weeks when the implants were embedded with six layers (162 microns) of PLA45GA10. This delivery system was implanted into the femoral condyle of rabbits. It was shown that the in vivo release was also closely regulated by the coating depth. In all bone tissues (bone marrow and cortical bone) surrounding the pellets, the drug concentration exceeded the Minimum Inhibitory Concentration for the common causative organisms of bone infections (Staphylococcus aureus) for at least four weeks without inducing serum toxic levels. Due to its cheapness, facility of use and sterilization, biocompatibility and biodegradability, plaster of Paris coated with PLA45GA10 polymer giving a controlled release of vancomycin appears to be a promising sustained release delivery system of antibiotics for the treatment of bone and joint infections.

  17. Scanning-electron-microscopy observations and mechanical characteristics of ion-beam-sputtered surgical implant alloys

    NASA Technical Reports Server (NTRS)

    Weigand, A. J.; Meyer, M. L.; Ling, J. S.

    1977-01-01

    An electron bombardment ion thruster was used as an ion source to sputter the surfaces of orthopedic prosthetic metals. Scanning electron microscopy photomicrographs were made of each ion beam textured surface. The effect of ion texturing an implant surface on its bond to bone cement was investigated. A Co-Cr-W alloy and surgical stainless steel were used as representative hard tissue implant materials to determine effects of ion texturing on bulk mechanical properties. Work was done to determine the effect of substrate temperature on the development of an ion textured surface microstructure. Results indicate that the ultimate strength of the bulk materials is unchanged by ion texturing and that the microstructure will develop more rapidly if the substrate is heated prior to ion texturing.

  18. An in vitro assessment of titanium functionalized with polysaccharides conjugated with vascular endothelial growth factor for enhanced osseointegration and inhibition of bacterial adhesion.

    PubMed

    Hu, Xuefeng; Neoh, Koon-Gee; Shi, Zhilong; Kang, En-Tang; Poh, Chyekhoon; Wang, Wilson

    2010-12-01

    The long-term success of orthopedic implants may be compromised by defective osseointegration and bacterial infection. An effective approach to minimize implant failure would be to modify the surface of the implant to make it habitable for bone-forming cells and anti-infective at the same time. In this in vitro study, the surfaces of titanium (Ti) substrates were functionalized by first covalently grafting either dopamine followed by carboxymethyl chitosan (CMCS) or hyaluronic acid-catechol (HAC). Vascular endothelial growth factor (VEGF) was then conjugated to the polysaccharide-grafted surface. Antibacterial assay with Staphylococcus aureus (S. aureus) showed that the polysaccharide-modified substrates significantly decrease bacterial adhesion. The CMCS-functionalized Ti demonstrated better antibacterial property than the HAC-functionalized Ti since CMCS is bactericidal while HA only inhibits the adhesion of bacteria without killing them. Osteoblast attachment, as well as alkaline phosphatase (ALP) activity and calcium deposition were enhanced by the immobilized VEGF on the polysaccharide-grafted Ti. Thus, Ti substrates modified with polysaccharides conjugated with VEGF can promote osteoblast functions and concurrently reduce bacterial adhesion. Since VEGF is also known to enhance angiogenesis, the VEGF-polysaccharide functionalized substrates will have promising applications in the orthopedic field. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Nano-scale surface morphology, wettability and osteoblast adhesion on nitrogen plasma-implanted NiTi shape memory alloy.

    PubMed

    Liu, X M; Wu, S L; Chu, Paul K; Chung, C Y; Chu, C L; Chan, Y L; Lam, K O; Yeung, K W K; Lu, W W; Cheung, K M C; Luk, K D K

    2009-06-01

    Plasma immersion ion implantation (PIII) is an effective method to increase the corrosion resistance and inhibit nickel release from orthopedic NiTi shape memory alloy. Nitrogen was plasma-implanted into NiTi using different pulsing frequencies to investigate the effects on the nano-scale surface morphology, structure, wettability, as well as biocompatibility. X-ray photoelectron spectroscopy (XPS) results show that the implantation depth of nitrogen increases with higher pulsing frequencies. Atomic force microscopy (AFM) discloses that the nano-scale surface roughness increases and surface features are changed from islands to spiky cones with higher pulsing frequencies. This variation in the nano surface structures leads to different surface free energy (SFE) monitored by contact angle measurements. The adhesion, spreading, and proliferation of osteoblasts on the implanted NiTi surface are assessed by cell culture tests. Our results indicate that the nano-scale surface morphology that is altered by the implantation frequencies impacts the surface free energy and wettability of the NiTi surfaces, and in turn affects the osteoblast adhesion behavior.

  20. Computer assisted outcomes research in orthopedics: total joint replacement.

    PubMed

    Arslanian, C; Bond, M

    1999-06-01

    Long-term studies are needed to determine clinically relevant outcomes within the practice of orthopedic surgery. Historically, the patient's subjective feelings of quality of life have been largely ignored. However, there has been a strong movement toward measuring perceived quality of life through such instruments as the SF-36. In a large database from an orthopedic practice results are presented. First, computerized data entry using touch screen technology is not only cost effective but user friendly. Second, patients undergoing hip or knee arthroplasty surgeries make statistically significant improvements in seven of the eight domains of the SF-36 in the first 3 months after surgery. Additional statistically significant improvements over the next 6 to 12 months are also seen. The data are presented here in detail to demonstrate the benefits of a patient outcomes program, to enhance the understanding and use of outcomes data and to encourage further work in outcomes measurement in orthopedics.