-
Two-dimensional phase unwrapping using robust derivative estimation and adaptive integration.
PubMed
Strand, Jarle; Taxt, Torfinn
2002-01-01
The adaptive integration (ADI) method for two-dimensional (2-D) phase unwrapping is presented. The method uses an algorithm for noise robust estimation of partial derivatives, followed by a noise robust adaptive integration process. The ADI method can easily unwrap phase images with moderate noise levels, and the resulting images are congruent modulo 2pi with the observed, wrapped, input images. In a quantitative evaluation, both the ADI and the BLS methods (Strand et al.) were better than the least-squares methods of Ghiglia and Romero (GR), and of Marroquin and Rivera (MRM). In a qualitative evaluation, the ADI, the BLS, and a conjugate gradient version of the MRM method (MRMCG), were all compared using a synthetic image with shear, using 115 magnetic resonance images, and using 22 fiber-optic interferometry images. For the synthetic image and the interferometry images, the ADI method gave consistently visually better results than the other methods. For the MR images, the MRMCG method was best, and the ADI method second best. The ADI method was less sensitive to the mask definition and the block size than the BLS method, and successfully unwrapped images with shears that were not marked in the masks. The computational requirements of the ADI method for images of nonrectangular objects were comparable to only two iterations of many least-squares-based methods (e.g., GR). We believe the ADI method provides a powerful addition to the ensemble of tools available for 2-D phase unwrapping.
-
A method for assigning species into groups based on generalized Mahalanobis distance between habitat model coefficients
USGS Publications Warehouse
Williams, C.J.; Heglund, P.J.
2009-01-01
Habitat association models are commonly developed for individual animal species using generalized linear modeling methods such as logistic regression. We considered the issue of grouping species based on their habitat use so that management decisions can be based on sets of species rather than individual species. This research was motivated by a study of western landbirds in northern Idaho forests. The method we examined was to separately fit models to each species and to use a generalized Mahalanobis distance between coefficient vectors to create a distance matrix among species. Clustering methods were used to group species from the distance matrix, and multidimensional scaling methods were used to visualize the relations among species groups. Methods were also discussed for evaluating the sensitivity of the conclusions because of outliers or influential data points. We illustrate these methods with data from the landbird study conducted in northern Idaho. Simulation results are presented to compare the success of this method to alternative methods using Euclidean distance between coefficient vectors and to methods that do not use habitat association models. These simulations demonstrate that our Mahalanobis-distance- based method was nearly always better than Euclidean-distance-based methods or methods not based on habitat association models. The methods used to develop candidate species groups are easily explained to other scientists and resource managers since they mainly rely on classical multivariate statistical methods. ?? 2008 Springer Science+Business Media, LLC.
-
Analytical difficulties facing today's regulatory laboratories: issues in method validation.
PubMed
MacNeil, James D
2012-08-01
The challenges facing analytical laboratories today are not unlike those faced in the past, although both the degree of complexity and the rate of change have increased. Challenges such as development and maintenance of expertise, maintenance and up-dating of equipment, and the introduction of new test methods have always been familiar themes for analytical laboratories, but international guidelines for laboratories involved in the import and export testing of food require management of such changes in a context which includes quality assurance, accreditation, and method validation considerations. Decisions as to when a change in a method requires re-validation of the method or on the design of a validation scheme for a complex multi-residue method require a well-considered strategy, based on a current knowledge of international guidance documents and regulatory requirements, as well the laboratory's quality system requirements. Validation demonstrates that a method is 'fit for purpose', so the requirement for validation should be assessed in terms of the intended use of a method and, in the case of change or modification of a method, whether that change or modification may affect a previously validated performance characteristic. In general, method validation involves method scope, calibration-related parameters, method precision, and recovery. Any method change which may affect method scope or any performance parameters will require re-validation. Some typical situations involving change in methods are discussed and a decision process proposed for selection of appropriate validation measures. © 2012 John Wiley & Sons, Ltd.
-
Statistical methods used to test for agreement of medical instruments measuring continuous variables in method comparison studies: a systematic review.
PubMed
Zaki, Rafdzah; Bulgiba, Awang; Ismail, Roshidi; Ismail, Noor Azina
2012-01-01
Accurate values are a must in medicine. An important parameter in determining the quality of a medical instrument is agreement with a gold standard. Various statistical methods have been used to test for agreement. Some of these methods have been shown to be inappropriate. This can result in misleading conclusions about the validity of an instrument. The Bland-Altman method is the most popular method judging by the many citations of the article proposing this method. However, the number of citations does not necessarily mean that this method has been applied in agreement research. No previous study has been conducted to look into this. This is the first systematic review to identify statistical methods used to test for agreement of medical instruments. The proportion of various statistical methods found in this review will also reflect the proportion of medical instruments that have been validated using those particular methods in current clinical practice. Five electronic databases were searched between 2007 and 2009 to look for agreement studies. A total of 3,260 titles were initially identified. Only 412 titles were potentially related, and finally 210 fitted the inclusion criteria. The Bland-Altman method is the most popular method with 178 (85%) studies having used this method, followed by the correlation coefficient (27%) and means comparison (18%). Some of the inappropriate methods highlighted by Altman and Bland since the 1980s are still in use. This study finds that the Bland-Altman method is the most popular method used in agreement research. There are still inappropriate applications of statistical methods in some studies. It is important for a clinician or medical researcher to be aware of this issue because misleading conclusions from inappropriate analyses will jeopardize the quality of the evidence, which in turn will influence quality of care given to patients in the future.
-
Statistical Methods Used to Test for Agreement of Medical Instruments Measuring Continuous Variables in Method Comparison Studies: A Systematic Review
PubMed Central
Zaki, Rafdzah; Bulgiba, Awang; Ismail, Roshidi; Ismail, Noor Azina
2012-01-01
Background Accurate values are a must in medicine. An important parameter in determining the quality of a medical instrument is agreement with a gold standard. Various statistical methods have been used to test for agreement. Some of these methods have been shown to be inappropriate. This can result in misleading conclusions about the validity of an instrument. The Bland-Altman method is the most popular method judging by the many citations of the article proposing this method. However, the number of citations does not necessarily mean that this method has been applied in agreement research. No previous study has been conducted to look into this. This is the first systematic review to identify statistical methods used to test for agreement of medical instruments. The proportion of various statistical methods found in this review will also reflect the proportion of medical instruments that have been validated using those particular methods in current clinical practice. Methodology/Findings Five electronic databases were searched between 2007 and 2009 to look for agreement studies. A total of 3,260 titles were initially identified. Only 412 titles were potentially related, and finally 210 fitted the inclusion criteria. The Bland-Altman method is the most popular method with 178 (85%) studies having used this method, followed by the correlation coefficient (27%) and means comparison (18%). Some of the inappropriate methods highlighted by Altman and Bland since the 1980s are still in use. Conclusions This study finds that the Bland-Altman method is the most popular method used in agreement research. There are still inappropriate applications of statistical methods in some studies. It is important for a clinician or medical researcher to be aware of this issue because misleading conclusions from inappropriate analyses will jeopardize the quality of the evidence, which in turn will influence quality of care given to patients in the future. PMID:22662248
-
Evaluation of PDA Technical Report No 33. Statistical Testing Recommendations for a Rapid Microbiological Method Case Study.
PubMed
Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David
2015-01-01
New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc. 2015.
-
[The research and application of pretreatment method for matrix-assisted laser desorption ionization-time of flight mass spectrometry identification of filamentous fungi].
PubMed
Huang, Y F; Chang, Z; Bai, J; Zhu, M; Zhang, M X; Wang, M; Zhang, G; Li, X Y; Tong, Y G; Wang, J L; Lu, X X
2017-08-08
Objective: To establish and evaluate the feasibility of a pretreatment method for matrix-assisted laser desorption ionization-time of flight mass spectrometry identification of filamentous fungi developed by the laboratory. Methods: Three hundred and eighty strains of filamentous fungi from January 2014 to December 2016 were recovered and cultured on sabouraud dextrose agar (SDA) plate at 28 ℃ to mature state. Meanwhile, the fungi were cultured in liquid sabouraud medium with a vertical rotation method recommended by Bruker and a horizontal vibration method developed by the laboratory until adequate amount of colonies were observed. For the strains cultured with the three methods, protein was extracted with modified magnetic bead-based extraction method for mass spectrum identification. Results: For 380 fungi strains, it took 3-10 d to culture with SDA culture method, and the ratio of identification of the species and genus was 47% and 81%, respectively; it took 5-7 d to culture with vertical rotation method, and the ratio of identification of the species and genus was 76% and 94%, respectively; it took 1-2 d to culture with horizontal vibration method, and the ratio of identification of the species and genus was 96% and 99%, respectively. For the comparison between horizontal vibration method and SDA culture method comparison, the difference was statistically significant (χ(2)=39.026, P <0.01); for the comparison between horizontal vibration method and vertical rotation method recommended by Bruker, the difference was statistically significant(χ(2)=11.310, P <0.01). Conclusion: The horizontal vibration method and modified magnetic bead-based extraction method developed by the laboratory is superior to the method recommended by Bruker and SDA culture method in terms of the identification capacity for filamentous fungi, which can be applied in clinic.
-
Development of a practical costing method for hospitals.
PubMed
Cao, Pengyu; Toyabe, Shin-Ichi; Akazawa, Kouhei
2006-03-01
To realize an effective cost control, a practical and accurate cost accounting system is indispensable in hospitals. In traditional cost accounting systems, the volume-based costing (VBC) is the most popular cost accounting method. In this method, the indirect costs are allocated to each cost object (services or units of a hospital) using a single indicator named a cost driver (e.g., Labor hours, revenues or the number of patients). However, this method often results in rough and inaccurate results. The activity based costing (ABC) method introduced in the mid 1990s can prove more accurate results. With the ABC method, all events or transactions that cause costs are recognized as "activities", and a specific cost driver is prepared for each activity. Finally, the costs of activities are allocated to cost objects by the corresponding cost driver. However, it is much more complex and costly than other traditional cost accounting methods because the data collection for cost drivers is not always easy. In this study, we developed a simplified ABC (S-ABC) costing method to reduce the workload of ABC costing by reducing the number of cost drivers used in the ABC method. Using the S-ABC method, we estimated the cost of the laboratory tests, and as a result, similarly accurate results were obtained with the ABC method (largest difference was 2.64%). Simultaneously, this new method reduces the seven cost drivers used in the ABC method to four. Moreover, we performed an evaluation using other sample data from physiological laboratory department to certify the effectiveness of this new method. In conclusion, the S-ABC method provides two advantages in comparison to the VBC and ABC methods: (1) it can obtain accurate results, and (2) it is simpler to perform. Once we reduce the number of cost drivers by applying the proposed S-ABC method to the data for the ABC method, we can easily perform the cost accounting using few cost drivers after the second round of costing.
-
Comparative study between recent methods manipulating ratio spectra and classical methods based on two-wavelength selection for the determination of binary mixture of antazoline hydrochloride and tetryzoline hydrochloride
NASA Astrophysics Data System (ADS)
Abdel-Halim, Lamia M.; Abd-El Rahman, Mohamed K.; Ramadan, Nesrin K.; EL Sanabary, Hoda F. A.; Salem, Maissa Y.
2016-04-01
A comparative study was developed between two classical spectrophotometric methods (dual wavelength method and Vierordt's method) and two recent methods manipulating ratio spectra (ratio difference method and first derivative of ratio spectra method) for simultaneous determination of Antazoline hydrochloride (AN) and Tetryzoline hydrochloride (TZ) in their combined pharmaceutical formulation and in the presence of benzalkonium chloride as a preservative without preliminary separation. The dual wavelength method depends on choosing two wavelengths for each drug in a way so that the difference in absorbance at those two wavelengths is zero for the other drug. While Vierordt's method, is based upon measuring the absorbance and the absorptivity values of the two drugs at their λmax (248.0 and 219.0 nm for AN and TZ, respectively), followed by substitution in the corresponding Vierordt's equation. Recent methods manipulating ratio spectra depend on either measuring the difference in amplitudes of ratio spectra between 255.5 and 269.5 nm for AN and 220.0 and 273.0 nm for TZ in case of ratio difference method or computing first derivative of the ratio spectra for each drug then measuring the peak amplitude at 250.0 nm for AN and at 224.0 nm for TZ in case of first derivative of ratio spectrophotometry. The specificity of the developed methods was investigated by analyzing different laboratory prepared mixtures of the two drugs. All methods were applied successfully for the determination of the selected drugs in their combined dosage form proving that the classical spectrophotometric methods can still be used successfully in analysis of binary mixture using minimal data manipulation rather than recent methods which require relatively more steps. Furthermore, validation of the proposed methods was performed according to ICH guidelines; accuracy, precision and repeatability are found to be within the acceptable limits. Statistical studies showed that the methods can be competitively applied in quality control laboratories.
-
Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.
PubMed
Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal
2017-11-24
Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements. Copyright © 2017 Elsevier B.V. All rights reserved.
-
New clinical validation method for automated sphygmomanometer: a proposal by Japan ISO-WG for sphygmomanometer standard.
PubMed
Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio
2007-12-01
Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.
-
[Significance of bacteria detection with filter paper method on diagnosis of diabetic foot wound infection].
PubMed
Zou, X H; Zhu, Y P; Ren, G Q; Li, G C; Zhang, J; Zou, L J; Feng, Z B; Li, B H
2017-02-20
Objective: To evaluate the significance of bacteria detection with filter paper method on diagnosis of diabetic foot wound infection. Methods: Eighteen patients with diabetic foot ulcer conforming to the study criteria were hospitalized in Liyuan Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology from July 2014 to July 2015. Diabetic foot ulcer wounds were classified according to the University of Texas diabetic foot classification (hereinafter referred to as Texas grade) system, and general condition of patients with wounds in different Texas grade was compared. Exudate and tissue of wounds were obtained, and filter paper method and biopsy method were adopted to detect the bacteria of wounds of patients respectively. Filter paper method was regarded as the evaluation method, and biopsy method was regarded as the control method. The relevance, difference, and consistency of the detection results of two methods were tested. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of filter paper method in bacteria detection were calculated. Receiver operating characteristic (ROC) curve was drawn based on the specificity and sensitivity of filter paper method in bacteria detection of 18 patients to predict the detection effect of the method. Data were processed with one-way analysis of variance and Fisher's exact test. In patients tested positive for bacteria by biopsy method, the correlation between bacteria number detected by biopsy method and that by filter paper method was analyzed with Pearson correlation analysis. Results: (1) There were no statistically significant differences among patients with wounds in Texas grade 1, 2, and 3 in age, duration of diabetes, duration of wound, wound area, ankle brachial index, glycosylated hemoglobin, fasting blood sugar, blood platelet count, erythrocyte sedimentation rate, C-reactive protein, aspartate aminotransferase, serum creatinine, and urea nitrogen (with F values from 0.029 to 2.916, P values above 0.05), while there were statistically significant differences among patients with wounds in Texas grade 1, 2, and 3 in white blood cell count and alanine aminotransferase (with F values 4.688 and 6.833 respectively, P <0.05 or P <0.01). (2) According to the results of biopsy method, 6 patients were tested negative for bacteria, and 12 patients were tested positive for bacteria, among which 10 patients were with bacterial number above 1×10(5)/g, and 2 patients with bacterial number below 1×10(5)/g. According to the results of filter paper method, 8 patients were tested negative for bacteria, and 10 patients were tested positive for bacteria, among which 7 patients were with bacterial number above 1×10(5)/g, and 3 patients with bacterial number below 1×10(5)/g. There were 7 patients tested positive for bacteria both by biopsy method and filter paper method, 8 patients tested negative for bacteria both by biopsy method and filter paper method, and 3 patients tested positive for bacteria by biopsy method but negative by filter paper method. Patients tested negative for bacteria by biopsy method did not tested positive for bacteria by filter paper method. There was directional association between the detection results of two methods ( P =0.004), i. e. if result of biopsy method was positive, result of filter paper method could also be positive. There was no obvious difference in the detection results of two methods ( P =0.250). The consistency between the detection results of two methods was ordinary (Kappa=0.68, P =0.002). (3) The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of filter paper method in bacteria detection were 70%, 100%, 1.00, 0.73, and 83.3%, respectively. Total area under ROC curve of bacteria detection by filter paper method in 18 patients was 0.919 (with 95% confidence interval 0-1.000, P =0.030). (4) There were 13 strains of bacteria detected by biopsy method, with 5 strains of Acinetobacter baumannii, 5 strains of Staphylococcus aureus, 1 strain of Pseudomonas aeruginosa, 1 strain of Streptococcus bovis, and 1 strain of bird Enterococcus . There were 11 strains of bacteria detected by filter paper method, with 5 strains of Acinetobacter baumannii, 3 strains of Staphylococcus aureus, 1 strain of Pseudomonas aeruginosa, 1 strain of Streptococcus bovis, and 1 strain of bird Enterococcus . Except for Staphylococcus aureus, the sensitivity and specificity of filter paper method in the detection of the other 4 bacteria were all 100%. The consistency between filter paper method and biopsy method in detecting Acinetobacter baumannii was good (Kappa=1.00, P <0.01), while that in detecting Staphylococcus aureus was ordinary (Kappa=0.68, P <0.05). (5) There was no obvious correlation between the bacteria number of wounds detected by filter paper method and that by biopsy method ( r =0.257, P =0.419). There was obvious correlation between the bacteria numbers detected by two methods in wounds with Texas grade 1 and 2 (with r values as 0.999, P values as 0.001). There was no obvious correlation between the bacteria numbers detected by two methods in wounds with Texas grade 3 ( r =-0.053, P =0.947). Conclusions: The detection result of filter paper method is in accordance with that of biopsy method in the determination of bacterial infection, and it is of great importance in the diagnosis of local infection of diabetic foot wound.
-
A k-space method for large-scale models of wave propagation in tissue.
PubMed
Mast, T D; Souriau, L P; Liu, D L; Tabei, M; Nachman, A I; Waag, R C
2001-03-01
Large-scale simulation of ultrasonic pulse propagation in inhomogeneous tissue is important for the study of ultrasound-tissue interaction as well as for development of new imaging methods. Typical scales of interest span hundreds of wavelengths; most current two-dimensional methods, such as finite-difference and finite-element methods, are unable to compute propagation on this scale with the efficiency needed for imaging studies. Furthermore, for most available methods of simulating ultrasonic propagation, large-scale, three-dimensional computations of ultrasonic scattering are infeasible. Some of these difficulties have been overcome by previous pseudospectral and k-space methods, which allow substantial portions of the necessary computations to be executed using fast Fourier transforms. This paper presents a simplified derivation of the k-space method for a medium of variable sound speed and density; the derivation clearly shows the relationship of this k-space method to both past k-space methods and pseudospectral methods. In the present method, the spatial differential equations are solved by a simple Fourier transform method, and temporal iteration is performed using a k-t space propagator. The temporal iteration procedure is shown to be exact for homogeneous media, unconditionally stable for "slow" (c(x) < or = c0) media, and highly accurate for general weakly scattering media. The applicability of the k-space method to large-scale soft tissue modeling is shown by simulating two-dimensional propagation of an incident plane wave through several tissue-mimicking cylinders as well as a model chest wall cross section. A three-dimensional implementation of the k-space method is also employed for the example problem of propagation through a tissue-mimicking sphere. Numerical results indicate that the k-space method is accurate for large-scale soft tissue computations with much greater efficiency than that of an analogous leapfrog pseudospectral method or a 2-4 finite difference time-domain method. However, numerical results also indicate that the k-space method is less accurate than the finite-difference method for a high contrast scatterer with bone-like properties, although qualitative results can still be obtained by the k-space method with high efficiency. Possible extensions to the method, including representation of absorption effects, absorbing boundary conditions, elastic-wave propagation, and acoustic nonlinearity, are discussed.
-
The method of planning the energy consumption for electricity market
NASA Astrophysics Data System (ADS)
Russkov, O. V.; Saradgishvili, S. E.
2017-10-01
The limitations of existing forecast models are defined. The offered method is based on game theory, probabilities theory and forecasting the energy prices relations. New method is the basis for planning the uneven energy consumption of industrial enterprise. Ecological side of the offered method is disclosed. The program module performed the algorithm of the method is described. Positive method tests at the industrial enterprise are shown. The offered method allows optimizing the difference between planned and factual consumption of energy every hour of a day. The conclusion about applicability of the method for addressing economic and ecological challenges is made.
-
Numerical solution of sixth-order boundary-value problems using Legendre wavelet collocation method
NASA Astrophysics Data System (ADS)
Sohaib, Muhammad; Haq, Sirajul; Mukhtar, Safyan; Khan, Imad
2018-03-01
An efficient method is proposed to approximate sixth order boundary value problems. The proposed method is based on Legendre wavelet in which Legendre polynomial is used. The mechanism of the method is to use collocation points that converts the differential equation into a system of algebraic equations. For validation two test problems are discussed. The results obtained from proposed method are quite accurate, also close to exact solution, and other different methods. The proposed method is computationally more effective and leads to more accurate results as compared to other methods from literature.
-
Modifications of the PCPT method for HJB equations
NASA Astrophysics Data System (ADS)
Kossaczký, I.; Ehrhardt, M.; Günther, M.
2016-10-01
In this paper we will revisit the modification of the piecewise constant policy timestepping (PCPT) method for solving Hamilton-Jacobi-Bellman (HJB) equations. This modification is called piecewise predicted policy timestepping (PPPT) method and if properly used, it may be significantly faster. We will quickly recapitulate the algorithms of PCPT, PPPT methods and of the classical implicit method and apply them on a passport option pricing problem with non-standard payoff. We will present modifications needed to solve this problem effectively with the PPPT method and compare the performance with the PCPT method and the classical implicit method.
-
Rapid Method for Sodium Hydroxide/Sodium Peroxide Fusion ...
EPA Pesticide Factsheets
Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Plutonium-238 and plutonium-239 in water and air filters Method Selected for: SAM lists this method as a pre-treatment technique supporting analysis of refractory radioisotopic forms of plutonium in drinking water and air filters using the following qualitative techniques: • Rapid methods for acid or fusion digestion • Rapid Radiochemical Method for Plutonium-238 and Plutonium 239/240 in Building Materials for Environmental Remediation Following Radiological Incidents. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.
-
The Importance of Method Selection in Determining Product Integrity for Nutrition Research1234
PubMed Central
Mudge, Elizabeth M; Brown, Paula N
2016-01-01
The American Herbal Products Association estimates that there as many as 3000 plant species in commerce. The FDA estimates that there are about 85,000 dietary supplement products in the marketplace. The pace of product innovation far exceeds that of analytical methods development and validation, with new ingredients, matrixes, and combinations resulting in an analytical community that has been unable to keep up. This has led to a lack of validated analytical methods for dietary supplements and to inappropriate method selection where methods do exist. Only after rigorous validation procedures to ensure that methods are fit for purpose should they be used in a routine setting to verify product authenticity and quality. By following systematic procedures and establishing performance requirements for analytical methods before method development and validation, methods can be developed that are both valid and fit for purpose. This review summarizes advances in method selection, development, and validation regarding herbal supplement analysis and provides several documented examples of inappropriate method selection and application. PMID:26980823
-
Development of a Double Glass Mounting Method Using Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) and its Evaluation for Permanent Mounting of Small Nematodes
PubMed Central
ZAHABIUN, Farzaneh; SADJJADI, Seyed Mahmoud; ESFANDIARI, Farideh
2015-01-01
Background: Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. Methods: A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. Results: The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Conclusion: Using this method is cost effective and fast for mounting of small nematodes comparing to classic method. PMID:26811729
-
An evaluation of the efficiency of cleaning methods in a bacon factory
PubMed Central
Dempster, J. F.
1971-01-01
The germicidal efficiencies of hot water (140-150° F.) under pressure (method 1), hot water + 2% (w/v) detergent solution (method 2) and hot water + detergent + 200 p.p.m. solution of available chlorine (method 3) were compared at six sites in a bacon factory. Results indicated that sites 1 and 2 (tiled walls) were satisfactorily cleaned by each method. It was therefore considered more economical to clean such surfaces routinely by method 1. However, this method was much less efficient (31% survival of micro-organisms) on site 3 (wooden surface) than methods 2 (7% survival) and 3 (1% survival). Likewise the remaining sites (dehairing machine, black scraper and table) were least efficiently cleaned by method 1. The most satisfactory results were obtained when these surfaces were treated by method 3. Pig carcasses were shown to be contaminated by an improperly cleaned black scraper. Repeated cleaning and sterilizing (method 3) of this equipment reduced the contamination on carcasses from about 70% to less than 10%. PMID:5291745