Sample records for outages

  1. Human Factors and Modeling Methods in the Development of Control Room Modernization Concepts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hugo, Jacques V.; Slay III, Lorenzo

    nuclear power plants. Although the nuclear industry has made steady improvement in outage optimization, each day of a refueling outage still represents an opportunity to save millions of dollars and each day an outage extends past its planned end date represents millions of dollars that may have been spent unnecessarily. Reducing planned outage duration or preventing outage extensions requires careful management of the outage schedule as well as constant oversight and monitoring of work completion during the outage execution. During a typical outage, there are typically more than 10,000 activities on the schedule that, if not managed efficiently, may causemore » expensive outage delays. Management of outages currently relies largely on paper-based resources and general-purpose office software. A typical tool currently used to monitor work performance is a burn-down curve, where total remaining activities are plotted against the baseline schedule to track bulk work completion progress. While these tools are useful, there is still considerable uncertainty during a typical outage that bulk work progress is adequate and therefore a lot of management time is spent analyzing the situation on a daily basis. This paper describes recent advances made in developing a framework for the design of visual outage information presentation, as well as an overview of the scientific principles that informed the development of the visualizations. To test the utility of advanced visual outage information presentation, an outage management dashboard software application was created as part of the Department of Energy’s Advanced Outage Control Center project. This dashboard is intended to present all the critical information an outage manager would need to understand the current status of a refueling outage. The dashboard presents the critical path, bulk work performance, key performance indicators, outage milestones and metrics relating current performance to historical performance. Additionally, the dashboard includes data analysis tools to allow outage managers to drill down into the underlying data to understand the drivers of the indicators.« less

  2. Simplified Approach Charts Improve Data Retrieval Performance

    PubMed Central

    Stewart, Michael; Laraway, Sean; Jordan, Kevin; Feary, Michael S.

    2016-01-01

    The effectiveness of different instrument approach charts to deliver minimum visibility and altitude information during airport equipment outages was investigated. Eighteen pilots flew simulated instrument approaches in three conditions: (a) normal operations using a standard approach chart (standard-normal), (b) equipment outage conditions using a standard approach chart (standard-outage), and (c) equipment outage conditions using a prototype decluttered approach chart (prototype-outage). Errors and retrieval times in identifying minimum altitudes and visibilities were measured. The standard-outage condition produced significantly more errors and longer retrieval times versus the standard-normal condition. The prototype-outage condition had significantly fewer errors and shorter retrieval times than did the standard-outage condition. The prototype-outage condition produced significantly fewer errors but similar retrieval times when compared with the standard-normal condition. Thus, changing the presentation of minima may reduce risk and increase safety in instrument approaches, specifically with airport equipment outages. PMID:28491009

  3. Development of Improved Graphical Displays for an Advanced Outage Control Center, Employing Human Factors Principles for Outage Schedule Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    St Germain, Shawn Walter; Farris, Ronald Keith; Thomas, Kenneth David

    The long-term viability of existing nuclear power plants in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet refueling outages are highly complex operations, involving multiple concurrent and dependent activitiesmore » that are somewhat challenging to coordinate; therefore, finding ways to improve refueling outage performance, while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center (AOCC) project is a research and development (R&D) demonstration activity under the LWRS Program. LWRS is an R&D program that works closely with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current fleet of NPPs. As such, the LWRS Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, INL is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. The overall focus is on developing an AOCC with the following capabilities that enables plant and OCC staff to; Collaborate in real-time to address emergent issues; Effectively communicate outage status to all workers involved in the outage; Effectively communicate discovered conditions in the field to the OCC; Provide real-time work status; Provide automatic pending support notifications; Provide real-time requirements monitoring; Maximize their collective situational awareness to improve decision-making; and Leverage macro data to better support resource allocation. INL has partnered with several commercial NPP utilities to develop a number of advanced outage management technologies. These outage management technologies have focused on both collaborative technologies for control centers and developing mobile technologies for NPP field workers. This report describes recent efforts made in developing a suite of outage technologies to support more effective schedule management. Currently, a master outage schedule is created months in advance using the plant’s existing scheduling software (e.g., Primavera P6). Typically, during the outage, the latest version of the schedule is printed at the beginning of each shift. INL and its partners are developing technologies that will have capabilities such as Automatic Schedule Updating, Automatic Pending Support Notifications, and the ability to allocate and schedule outage support task resources on a sub-hour basis (e.g., outage Micro-Scheduling). The remaining sections of this report describe in more detail the scheduling challenges that occur during outages, how the outage scheduling technologies INL is developing helps address those challenges, and the latest developments on this task (e.g., work accomplished to date and the path forward)« less

  4. ALARA database value in future outage work planning and dose management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.W.; Green, W.H.

    1995-03-01

    ALARA database encompassing job-specific duration and man-rem plant specific information over three refueling outages represents an invaluable tool for the outage work planner and ALARA engineer. This paper describes dose-management trends emerging based on analysis of three refueling outages at Clinton Power Station. Conclusions reached based on hard data available from a relational database dose-tracking system is a valuable tool for planning of future outage work. The system`s ability to identify key problem areas during a refueling outage is improving as more outage comparative data becomes available. Trends over a three outage period are identified in this paper in themore » categories of number and type of radiation work permits implemented, duration of jobs, projected vs. actual dose rates in work areas, and accuracy of outage person-rem projection. The value of the database in projecting 1 and 5 year station person-rem estimates is discussed.« less

  5. Status Report on the Development of Micro-Scheduling Software for the Advanced Outage Control Center Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germain, Shawn St.; Thomas, Kenneth; Farris, Ronald

    2014-09-01

    The long-term viability of existing nuclear power plants (NPPs) in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet, refueling outages are highly complex operations, involving multiple concurrent and dependentmore » activities that are difficult to coordinate. Finding ways to improve refueling outage performance while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center project is a research and development (R&D) demonstration activity under the Light Water Reactor Sustainability (LWRS) Program. LWRS is a R&D program which works with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current NPPs. The Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, this INL R&D project is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This report describes specific recent efforts to develop a capability called outage Micro-Scheduling. Micro-Scheduling is the ability to allocate and schedule outage support task resources on a sub-hour basis. Micro-Scheduling is the real-time fine-tuning of the outage schedule to react to the actual progress of the primary outage activities to ensure that support task resources are optimally deployed with the least amount of delay and unproductive use of resources. The remaining sections of this report describe in more detail the scheduling challenges that occur during outages, how a Micro-Scheduling capability helps address those challenges, and provides a status update on work accomplished to date and the path forward.« less

  6. Effect of global warming on willingness to pay for uninterrupted electricity supply in European nations

    NASA Astrophysics Data System (ADS)

    Cohen, Jed; Moeltner, Klaus; Reichl, Johannes; Schmidthaler, Michael

    2018-01-01

    Predicted changes in temperature and other weather events may damage the electricity grid and cause power outages. Understanding the costs of power outages and how these costs change over time with global warming can inform outage-mitigation-investment decisions. Here we show that across 19 EU nations the value of uninterrupted electricity supply is strongly related to local temperatures, and will increase as the climate warms. Bayesian hierarchical modelling of data from a choice experiment and respondent-specific temperature measures reveals estimates of willingness to pay (WTP) to avoid an hour of power outage between €0.32 and €1.86 per household. WTP varies on the basis of season and is heterogeneous between European nations. Winter outages currently cause larger per household welfare losses than summer outages per hour of outage. However, this dynamic will begin to shift under plausible future climates, with summer outages becoming substantially more costly and winter outages becoming slightly less costly on a per-household, per-hour basis.

  7. Hurricane Isaac: A Longitudinal Analysis of Storm Characteristics and Power Outage Risk.

    PubMed

    Tonn, Gina L; Guikema, Seth D; Ferreira, Celso M; Quiring, Steven M

    2016-10-01

    In August 2012, Hurricane Isaac, a Category 1 hurricane at landfall, caused extensive power outages in Louisiana. The storm brought high winds, storm surge, and flooding to Louisiana, and power outages were widespread and prolonged. Hourly power outage data for the state of Louisiana were collected during the storm and analyzed. This analysis included correlation of hourly power outage figures by zip code with storm conditions including wind, rainfall, and storm surge using a nonparametric ensemble data mining approach. Results were analyzed to understand how correlation of power outages with storm conditions differed geographically within the state. This analysis provided insight on how rainfall and storm surge, along with wind, contribute to power outages in hurricanes. By conducting a longitudinal study of outages at the zip code level, we were able to gain insight into the causal drivers of power outages during hurricanes. Our analysis showed that the statistical importance of storm characteristic covariates to power outages varies geographically. For Hurricane Isaac, wind speed, precipitation, and previous outages generally had high importance, whereas storm surge had lower importance, even in zip codes that experienced significant surge. The results of this analysis can inform the development of power outage forecasting models, which often focus strictly on wind-related covariates. Our study of Hurricane Isaac indicates that inclusion of other covariates, particularly precipitation, may improve model accuracy and robustness across a range of storm conditions and geography. © 2016 Society for Risk Analysis.

  8. Benchmark Report on Key Outage Attributes: An Analysis of Outage Improvement Opportunities and Priorities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germain, Shawn St.; Farris, Ronald

    2014-09-01

    Advanced Outage Control Center (AOCC), is a multi-year pilot project targeted at Nuclear Power Plant (NPP) outage improvement. The purpose of this pilot project is to improve management of NPP outages through the development of an AOCC that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This report documents the results of a benchmarking effort to evaluate the transferability of technologies demonstrated at Idaho National Laboratory and the primary pilot project partner, Palo Verde Nuclear Generating Station. The initial assumption for this pilot project was that NPPs generally domore » not take advantage of advanced technology to support outage management activities. Several researchers involved in this pilot project have commercial NPP experience and believed that very little technology has been applied towards outage communication and collaboration. To verify that the technology options researched and demonstrated through this pilot project would in fact have broad application for the US commercial nuclear fleet, and to look for additional outage management best practices, LWRS program researchers visited several additional nuclear facilities.« less

  9. Synergistic Use of Nighttime Satellite Data, Electric Utility Infrastructure, and Ambient Population to Improve Power Outage Detections in Urban Areas

    NASA Technical Reports Server (NTRS)

    Cole, Tony A.; Wanik, David W.; Molthan, Andrew L.; Roman, Miguel O.; Griffin, Robert E.

    2017-01-01

    Natural and anthropogenic hazards are frequently responsible for disaster events, leading to damaged physical infrastructure, which can result in loss of electrical power for affected locations. Remotely-sensed, nighttime satellite imagery from the Suomi National Polar-orbiting Partnership (Suomi-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) can monitor power outages in disaster-affected areas through the identification of missing city lights. When combined with locally-relevant geospatial information, these observations can be used to estimate power outages, defined as geographic locations requiring manual intervention to restore power. In this study, we produced a power outage product based on Suomi-NPP VIIRS DNB observations to estimate power outages following Hurricane Sandy in 2012. This product, combined with known power outage data and ambient population estimates, was then used to predict power outages in a layered, feedforward neural network model. We believe this is the first attempt to synergistically combine such data sources to quantitatively estimate power outages. The VIIRS DNB power outage product was able to identify initial loss of light following Hurricane Sandy, as well as the gradual restoration of electrical power. The neural network model predicted power outages with reasonable spatial accuracy, achieving Pearson coefficients (r) between 0.48 and 0.58 across all folds. Our results show promise for producing a continental United States (CONUS)- or global-scale power outage monitoring network using satellite imagery and locally-relevant geospatial data.

  10. Seasonal and Local Characteristics of Lightning Outages of Power Distribution Lines in Hokuriku Area

    NASA Astrophysics Data System (ADS)

    Sugimoto, Hitoshi; Shimasaki, Katsuhiko

    The proportion of the lightning outages in all outages on Japanese 6.6kV distribution lines is high with approximately 20 percent, and then lightning protections are very important for supply reliability of 6.6kV lines. It is effective for the lightning performance to apply countermeasures in order of the area where a large number of the lightning outages occur. Winter lightning occurs in Hokuriku area, therefore it is also important to understand the seasonal characteristics of the lightning outages. In summer 70 percent of the lightning outages on distribution lines in Hokuriku area were due to sparkover, such as power wire breakings and failures of pole-mounted transformers. However, in winter almost half of lightning-damaged equipments were surge arrester failures. The number of the lightning outages per lightning strokes detected by the lightning location system (LLS) in winter was 4.4 times larger than that in summer. The authors have presumed the occurrence of lightning outages from lightning stroke density, 50% value of lightning current and installation rate of lightning protection equipments and overhead ground wire by multiple regression analysis. The presumed results suggest the local difference in the lightning outages.

  11. A simple model for DSS-14 outage times

    NASA Technical Reports Server (NTRS)

    Rumsey, H. C.; Stevens, R.; Posner, E. C.

    1989-01-01

    A model is proposed to describe DSS-14 outage times. Discrepancy Reporting System outage data for the period from January 1986 through September 1988 are used to estimate the parameters of the model. The model provides a probability distribution for the duration of outages, which agrees well with observed data. The model depends only on a small number of parameters, and has some heuristic justification. This shows that the Discrepancy Reporting System in the Deep Space Network (DSN) can be used to estimate the probability of extended outages in spite of the discrepancy reports ending when the pass ends. The probability of an outage extending beyond the end of a pass is estimated as around 5 percent.

  12. Outage maintenance checks on large generator windings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nindra, B.; Jeney, S.I.; Slobodinsky, Y.

    In the present days of austerity, more constraints and pressures are being brought on the maintenance engineers to certify the generators for their reliability and life extension. The outages are shorter and intervals between the outages are becoming longer. The annual outages were very common when utilities had no regulatory constraints and also had standby capacities. Furthermore, due to lean and mean budgets, outage maintenance programs are being pursued more aggressively, so that longer interval outages can be achieved to ensure peak generator performance. This paper will discuss various visual checks, electrical tests and recommended fixes to achieve the abovemore » mentioned objectives, in case any deficiencies are found.« less

  13. Outage differences between Diablo Canyon and Unterweser power plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mehrens, H.

    Diablo Canyon (DCPP) of Pacific Gas and Electric Company and Unterweser (KKU) of PreussenElektra have had an ongoing exchange program since 1989, which includes mutual visits by their employees at the optimum time for observing outages. Both DCPP and Unterweser use four-loop pressurized water reactors (PWRs), DCPP with two 1,100-MW units and KKU with a single 1,300-MW unit. Unterweser finished its 11th outage in 1990; DCPP units 1 and 2 will have their fourth outages in 1991. The scope of the maintenance and refueling work is quite similar in both plants and offers, therefore, a good basis for comparison. Outagemore » durations at European Kraftwerk Union KWU-PWR plants average {approximately}30 days as compared to the 60 to 80 days for PWRs in the US. Diablo Canyon has reduced outage durations from > 100 days to < 60. The key areas that contribute to the differences in outage duration are plant design and layout and outage execution.« less

  14. 2006 Update of Business Downtime Costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinrichs, Mr. Doug; Goggin, Mr. Michael

    2007-01-01

    The objective of this paper is to assess the downtime cost of power outages to businesses in the commercial and industrial sectors, updating and improving upon studies that have already been published on this subject. The goal is to produce a study that, relative to existing studies, (1) applies to a wider set of business types (2) reflects more current downtime costs, (3) accounts for the time duration factor of power outages, and (4) includes data on the costs imposed by real outages in a well-defined market. This study examines power outage costs in 11 commercial subsectors and 5 industrialmore » subsectors, using data on downtime costs that was collected in the 1990's. This study also assesses power outage costs for power outages of 20 minutes, 1 hour, and 4 hours duration. Finally, this study incorporates data on the costs of real power outages for two business subsectors. However, the current limited state of data availability on the topic of downtime costs means there is room to improve upon this study. Useful next steps would be to generate more recent data on downtime costs, data that covers outages shorter than 20 minutes duration and longer than 4 hours duration, and more data that is based on the costs caused by real-world outages. Nevertheless, with the limited data that is currently available, this study is able to generate a clear and detailed picture of the downtime costs that are faced by different types of businesses.« less

  15. Predicting Power Outages Using Multi-Model Ensemble Forecasts

    NASA Astrophysics Data System (ADS)

    Cerrai, D.; Anagnostou, E. N.; Yang, J.; Astitha, M.

    2017-12-01

    Power outages affect every year millions of people in the United States, affecting the economy and conditioning the everyday life. An Outage Prediction Model (OPM) has been developed at the University of Connecticut for helping utilities to quickly restore outages and to limit their adverse consequences on the population. The OPM, operational since 2015, combines several non-parametric machine learning (ML) models that use historical weather storm simulations and high-resolution weather forecasts, satellite remote sensing data, and infrastructure and land cover data to predict the number and spatial distribution of power outages. A new methodology, developed for improving the outage model performances by combining weather- and soil-related variables using three different weather models (WRF 3.7, WRF 3.8 and RAMS/ICLAMS), will be presented in this study. First, we will present a performance evaluation of each model variable, by comparing historical weather analyses with station data or reanalysis over the entire storm data set. Hence, each variable of the new outage model version is extracted from the best performing weather model for that variable, and sensitivity tests are performed for investigating the most efficient variable combination for outage prediction purposes. Despite that the final variables combination is extracted from different weather models, this ensemble based on multi-weather forcing and multi-statistical model power outage prediction outperforms the currently operational OPM version that is based on a single weather forcing variable (WRF 3.7), because each model component is the closest to the actual atmospheric state.

  16. Technology Integration Initiative In Support of Outage Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregory Weatherby; David Gertman

    2012-07-01

    Plant outage management is a high priority concern for the nuclear industry from cost and safety perspectives. Often, command and control during outages is maintained in the outage control center where many of the underlying technologies supporting outage control are the same as those used in the 1980’s. This research reports on the use of advanced integrating software technologies and hand held mobile devices as a means by which to reduce cycle time, improve accuracy, and enhance transparency among outage team members. This paper reports on the first phase of research supported by the DOE Light Water Reactor Sustainability (LWRS)more » Program that is performed in close collaboration with industry to examine the introduction of newly available technology allowing for safe and efficient outage performance. It is thought that this research will result in: improved resource management among various plant stakeholder groups, reduced paper work, and enhanced overall situation awareness for the outage control center management team. A description of field data collection methods, including personnel interview data, success factors, end-user evaluation and integration of hand held devices in achieving an integrated design are also evaluated. Finally, the necessity of obtaining operations cooperation support in field studies and technology evaluation is acknowledged.« less

  17. The role of the AWS CWI in a major power plant outage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walsh, T.W.

    In March of 1988, an eight-week outage began at the Keystone Electric Generating Station, 35 miles northwest of Johnstown, Pa. This outage encompassed the complete replacement of the reheat section of a 1,7000,000 kW boiler unit, as well as major repairs to the boiler itself. The author discusses how AWS (Certified Welding Inspectors) (CWl's) played a major part in the successful completion of over 7600 ASME butt joint welds during the outage. The welding on these outages is performed in strict accordance with the Pennsylvania Electric Company Quanity Assurance Specification and the applicable codes (ASME, NBIC, ANSI and AWS).

  18. Synthesis of power plant outage schedules. Final technical report, April 1995-January 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, D.R.

    This document provides a report on the creation of domain theories in the power plant outage domain. These were developed in conjunction with the creation of a demonstration system of advanced scheduling technology for the outage problem. In 1994 personnel from Rome Laboratory (RL), Kaman Science (KS), Kestrel Institute, and the Electric Power Research Institute (EPRI) began a joint project to develop scheduling tools for power plant outage activities. This report describes our support for this joint effort. The project uses KIDS (Kestrel Interactive Development System) to generate schedulers from formal specifications of the power plant domain outage activities.

  19. A Bayesian Approach Based Outage Prediction in Electric Utility Systems Using Radar Measurement Data

    DOE PAGES

    Yue, Meng; Toto, Tami; Jensen, Michael P.; ...

    2017-05-18

    Severe weather events such as strong thunderstorms are some of the most significant and frequent threats to the electrical grid infrastructure. Outages resulting from storms can be very costly. While some tools are available to utilities to predict storm occurrences and damage, they are typically very crude and provide little means of facilitating restoration efforts. This study developed a methodology to use historical high-resolution (both temporal and spatial) radar observations of storm characteristics and outage information to develop weather condition dependent failure rate models (FRMs) for different grid components. Such models can provide an estimation or prediction of the outagemore » numbers in small areas of a utility’s service territory once the real-time measurement or forecasted data of weather conditions become available as the input to the models. Considering the potential value provided by real-time outages reported, a Bayesian outage prediction (BOP) algorithm is proposed to account for both strength and uncertainties of the reported outages and failure rate models. The potential benefit of this outage prediction scheme is illustrated in this study.« less

  20. A Bayesian Approach Based Outage Prediction in Electric Utility Systems Using Radar Measurement Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, Meng; Toto, Tami; Jensen, Michael P.

    Severe weather events such as strong thunderstorms are some of the most significant and frequent threats to the electrical grid infrastructure. Outages resulting from storms can be very costly. While some tools are available to utilities to predict storm occurrences and damage, they are typically very crude and provide little means of facilitating restoration efforts. This study developed a methodology to use historical high-resolution (both temporal and spatial) radar observations of storm characteristics and outage information to develop weather condition dependent failure rate models (FRMs) for different grid components. Such models can provide an estimation or prediction of the outagemore » numbers in small areas of a utility’s service territory once the real-time measurement or forecasted data of weather conditions become available as the input to the models. Considering the potential value provided by real-time outages reported, a Bayesian outage prediction (BOP) algorithm is proposed to account for both strength and uncertainties of the reported outages and failure rate models. The potential benefit of this outage prediction scheme is illustrated in this study.« less

  1. Development of Methodologies for Technology Deployment for Advanced Outage Control Centers that Improve Outage Coordination, Problem Resolution and Outage Risk Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shawn St. Germain; Ronald Farris; Heather Medeman

    2013-09-01

    This research effort is a part of the Light-Water Reactor Sustainability (LWRS) Program, which is a research and development (R&D) program sponsored by Department of Energy (DOE) and performed in close collaboration with industry R&D programs that provides the technical foundations for licensing and managing the long-term, safe, and economical operation of current nuclear power plants. The LWRS program serves to help the U.S. nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. The long term viability of existing nuclear power plants in the U.S.more » will depend upon maintaining high capacity factors, avoiding nuclear safety issues and reducing operating costs. The slow progress in the construction on new nuclear power plants has placed in increased importance on maintaining the output of the current fleet of nuclear power plants. Recently expanded natural gas production has placed increased economic pressure on nuclear power plants due to lower cost competition. Until recently, power uprate projects had steadily increased the total output of the U.S. nuclear fleet. Errors made during power plant upgrade projects have now removed three nuclear power plants from the U.S. fleet and economic considerations have caused the permanent shutdown of a fourth plant. Additionally, several utilities have cancelled power uprate projects citing economic concerns. For the past several years net electrical generation from U.S. nuclear power plants has been declining. One of few remaining areas where significant improvements in plant capacity factors can be made is in minimizing the duration of refueling outages. Managing nuclear power plant outages is a complex and difficult task. Due to the large number of complex tasks and the uncertainty that accompanies them, outage durations routinely exceed the planned duration. The ability to complete an outage on or near schedule depends upon the performance of the outage management organization. During an outage, the outage control center (OCC) is the temporary command center for outage managers and provides several critical functions for the successful execution of the outage schedule. Essentially, the OCC functions to facilitate information inflow, assist outage management in processing information and to facilitate the dissemination of information to stakeholders. Currently, outage management activities primarily rely on telephone communication, face to face reports of status and periodic briefings in the OCC. Much of the information displayed in OCCs is static and out of date requiring an evaluation to determine if it is still valid. Several advanced communication and collaboration technologies have shown promise for facilitating the information flow into, across and out of the OCC. Additionally, advances in the areas of mobile worker technologies, computer based procedures and electronic work packages can be leveraged to improve the availability of real time status to outage managers.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carpentier, J.L.; Di Bono, P.J.; Tournebise, P.J.

    The efficient bounding method for DC contingency analysis is improved using reciprocity properties. Knowing the consequences of the outage of a branch, these properties provide the consequences on that branch of various kinds of outages. This is used in order to reduce computation times and to get rid of some difficulties, such as those occurring when a branch flow is close to its limit before outage. Compensation, sparse vector, sparse inverse and bounding techniques are also used. A program has been implemented for single branch outages and tested on actual French EHV 650 bus network. Computation times are 60% ofmore » the Efficient Bounding method. The relevant algorithm is described in detail in the first part of this paper. In the second part, reciprocity properties and bounding formulas are extended for multiple branch outages and for multiple generator or load outages. An algorithm is proposed in order to handle all these cases simultaneously.« less

  3. Estimating Power Outage Cost based on a Survey for Industrial Customers

    NASA Astrophysics Data System (ADS)

    Yoshida, Yoshikuni; Matsuhashi, Ryuji

    A survey was conducted on power outage cost for industrial customers. 5139 factories, which are designated energy management factories in Japan, answered their power consumption and the loss of production value due to the power outage in an hour in summer weekday. The median of unit cost of power outage of whole sectors is estimated as 672 yen/kWh. The sector of services for amusement and hobbies and the sector of manufacture of information and communication electronics equipment relatively have higher unit cost of power outage. Direct damage cost from power outage in whole sectors reaches 77 billion yen. Then utilizing input-output analysis, we estimated indirect damage cost that is caused by the repercussion of production halt. Indirect damage cost in whole sectors reaches 91 billion yen. The sector of wholesale and retail trade has the largest direct damage cost. The sector of manufacture of transportation equipment has the largest indirect damage cost.

  4. The cost of power outages in the business and public sectors in Israel: Revealed preference vs. subjective evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beenstock, M.; Goldin, E.; Haitovsky, Y.

    1997-05-01

    The economic cost of power outages is a central parameter in the cost-benefit analysis of electric power reliability and the design of electric power systems. The authors present a new methodology for estimating the cost of power outages in the business and public sections and illustrate with data for Israel. The methodology is based on the principle of revealed preference, the cost of an outage may be inferred from the actions taken by consumers to mitigate losses induced by unsupplied electricity. If outages impose costs on businesses, managers are likely to invest in back-up power to mitigate the losses thatmore » are incurred when electricity is not supplied. Investment in back-up generators may then be used to impute the mitigated and unmitigated damage from outages. 12 refs., 3 figs., 7 tabs.« less

  5. Does NASA SMAP Improve the Accuracy of Power Outage Models?

    NASA Astrophysics Data System (ADS)

    Quiring, S. M.; McRoberts, D. B.; Toy, B.; Alvarado, B.

    2016-12-01

    Electric power utilities make critical decisions in the days prior to hurricane landfall that are primarily based on the estimated impact to their service area. For example, utilities must determine how many repair crews to request from other utilities, the amount of material and equipment they will need to make repairs, and where in their geographically expansive service area to station crews and materials. Accurate forecasts of the impact of an approaching hurricane within their service area are critical for utilities in balancing the costs and benefits of different levels of resources. The Hurricane Outage Prediction Model (HOPM) are a family of statistical models that utilize predictions of tropical cyclone windspeed and duration of strong winds, along with power system and environmental variables (e.g., soil moisture, long-term precipitation), to forecast the number and location of power outages. This project assesses whether using NASA SMAP soil moisture improves the accuracy of power outage forecasts as compared to using model-derived soil moisture from NLDAS-2. A sensitivity analysis is employed since there have been very few tropical cyclones making landfall in the United States since SMAP was launched. The HOPM is used to predict power outages for 13 historical tropical cyclones and the model is run using twice, once with NLDAS soil moisture and once with SMAP soil moisture. Our results demonstrate that using SMAP soil moisture can have a significant impact on power outage predictions. SMAP has the potential to enhance the accuracy of power outage forecasts. Improved outage forecasts reduce the duration of power outages which reduces economic losses and accelerates recovery.

  6. Enhanced outage prediction modeling for strong extratropical storms and hurricanes in the Northeastern United States

    NASA Astrophysics Data System (ADS)

    Cerrai, D.; Anagnostou, E. N.; Wanik, D. W.; Bhuiyan, M. A. E.; Zhang, X.; Yang, J.; Astitha, M.; Frediani, M. E.; Schwartz, C. S.; Pardakhti, M.

    2016-12-01

    The overwhelming majority of human activities need reliable electric power. Severe weather events can cause power outages, resulting in substantial economic losses and a temporary worsening of living conditions. Accurate prediction of these events and the communication of forecasted impacts to the affected utilities is necessary for efficient emergency preparedness and mitigation. The University of Connecticut Outage Prediction Model (OPM) uses regression tree models, high-resolution weather reanalysis and real-time weather forecasts (WRF and NCAR ensemble), airport station data, vegetation and electric grid characteristics and historical outage data to forecast the number and spatial distribution of outages in the power distribution grid located within dense vegetation. Recent OPM improvements consist of improved storm classification and addition of new predictive weather-related variables and are demonstrated using a leave-one-storm-out cross-validation based on 130 severe extratropical storms and two hurricanes (Sandy and Irene) in the Northeast US. We show that it is possible to predict the number of trouble spots causing outages in the electric grid with a median absolute percentage error as low as 27% for some storm types, and at most around 40%, in a scale that varies between four orders of magnitude, from few outages to tens of thousands. This outage information can be communicated to the electric utility to manage allocation of crews and equipment and minimize the recovery time for an upcoming storm hazard.

  7. Effects of Phasor Measurement Uncertainty on Power Line Outage Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chen; Wang, Jianhui; Zhu, Hao

    2014-12-01

    Phasor measurement unit (PMU) technology provides an effective tool to enhance the wide-area monitoring systems (WAMSs) in power grids. Although extensive studies have been conducted to develop several PMU applications in power systems (e.g., state estimation, oscillation detection and control, voltage stability analysis, and line outage detection), the uncertainty aspects of PMUs have not been adequately investigated. This paper focuses on quantifying the impact of PMU uncertainty on power line outage detection and identification, in which a limited number of PMUs installed at a subset of buses are utilized to detect and identify the line outage events. Specifically, the linemore » outage detection problem is formulated as a multi-hypothesis test, and a general Bayesian criterion is used for the detection procedure, in which the PMU uncertainty is analytically characterized. We further apply the minimum detection error criterion for the multi-hypothesis test and derive the expected detection error probability in terms of PMU uncertainty. The framework proposed provides fundamental guidance for quantifying the effects of PMU uncertainty on power line outage detection. Case studies are provided to validate our analysis and show how PMU uncertainty influences power line outage detection.« less

  8. How individual traces and interactive timelines could support outage execution - Toward an outage historian concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parfouru, S.; De-Beler, N.

    2012-07-01

    In the context of a project that is designing innovative ICT-based solutions for the organizational concept of outage management, we focus on the informational process of the OCR (Outage Control Room) underlying the execution of the outages. Informational process are based on structured and unstructured documents that have a key role in the collaborative processes and management of the outage. We especially track the structured and unstructured documents, electronically or not, from creation to sharing. Our analysis allows us to consider that the individual traces produced by an individual participant with a specific role could be multi-purpose and support sharingmore » between participants without creating duplication of work. The ultimate goal is to be able to generate an outage historian, that is not just focused on highly structured information, which could be useful to improve the continuity of information between participants. We study the implementation of this approach through web technologies and social media tools to address this issue. We also investigate the issue of data access through interactive visualization timelines coupled with other modality's to assist users in the navigation and exploration of the proposed historian. (authors)« less

  9. Estimating the Propagation of Interdependent Cascading Outages with Multi-Type Branching Processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, Junjian; Ju, Wenyun; Sun, Kai

    In this paper, the multi-type branching process is applied to describe the statistics and interdependencies of line outages, the load shed, and isolated buses. The offspring mean matrix of the multi-type branching process is estimated by the Expectation Maximization (EM) algorithm and can quantify the extent of outage propagation. The joint distribution of two types of outages is estimated by the multi-type branching process via the Lagrange-Good inversion. The proposed model is tested with data generated by the AC OPA cascading simulations on the IEEE 118-bus system. The largest eigenvalues of the offspring mean matrix indicate that the system ismore » closer to criticality when considering the interdependence of different types of outages. Compared with empirically estimating the joint distribution of the total outages, good estimate is obtained by using the multitype branching process with a much smaller number of cascades, thus greatly improving the efficiency. It is shown that the multitype branching process can effectively predict the distribution of the load shed and isolated buses and their conditional largest possible total outages even when there are no data of them.« less

  10. Home Use Devices: How to Prepare for and Handle Power Outages for Medical Devices That Require Electricity

    MedlinePlus

    ... Handle Power Outages for Medical Devices that Require Electricity Center for De CDRH vices and Rad lth ... Handle Power Outages for Medical Devices that Require Electricity As a home medical device user, it is ...

  11. Fluidized bed operations survey summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lombardi, C.

    1996-12-31

    A fluidized bed operations survey summary is presented. The survey contains information on: forced outage causes; forced outage concerns ranked numerically; 1996 boiler operation and maintenance (O&M) concerns; 1997 boiler O&M concerns; fluidized bed capacity factor results; and fluidized bed total outage time.

  12. Development of an Overview Display to Allow Advanced Outage Control Center Management to Quickly Evaluate Outage Status

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    St Germain, Shawn Walter; Hugo, Jacques Victor

    This report describes recent advances made in developing a framework for the design of visual outage information presentation, as well as an overview of the scientific principles that informed the development of the visualizations.

  13. 77 FR 63757 - Extension of the Commission's Rules Regarding Outage Reporting to Interconnected Voice Over...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-17

    ... Commission's Rules Regarding Outage Reporting to Interconnected Voice Over Internet Protocol Service Providers and Broadband Internet Service Providers AGENCY: Federal Communications Commission. ACTION: Final... Regarding Outage Reporting to Interconnected Voice Over Internet Protocol Service Providers and Broadband...

  14. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... submit electronically an Initial Communications Outage Report to the Commission. Not later than thirty days after discovering the outage, the provider shall submit electronically a Final Communications... cannot be obtained through any of the methods described, for whatever reason, then the provider shall...

  15. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... submit electronically an Initial Communications Outage Report to the Commission. Not later than thirty days after discovering the outage, the provider shall submit electronically a Final Communications... cannot be obtained through any of the methods described, for whatever reason, then the provider shall...

  16. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... submit electronically an Initial Communications Outage Report to the Commission. Not later than thirty days after discovering the outage, the provider shall submit electronically a Final Communications... cannot be obtained through any of the methods described, for whatever reason, then the provider shall...

  17. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... submit electronically an Initial Communications Outage Report to the Commission. Not later than thirty days after discovering the outage, the provider shall submit electronically a Final Communications... cannot be obtained through any of the methods described, for whatever reason, then the provider shall...

  18. Economic costs of electrical system instability and power outages caused by snakes on the Island of Guam

    USGS Publications Warehouse

    Fritts, T.H.

    2002-01-01

    The Brown Tree Snake, Boiga irregularis, is an introduced species on Guam where it causes frequent electrical power outages. The snake's high abundance, its propensity for climbing, and use of disturbed habitats all contribute to interruption of Guam's electrical service and the activities that depend on electrical power. Snakes have caused more than 1600 power outages in the 20-yr period of 1978-1997 and most recently nearly 200 outages per year. Single outages spanning the entire island and lasting 8 or more hours are estimated to cost in excess of $3,000,000 in lost productivity, but the costs of outages that involve only parts of the island or those of shorter durations are more difficult to quantify. Costs to the island's economy have exceeded $4.5 M per year over a 7-yr period without considering repair costs, damage to electrical equipment, and lost revenues. Snakes pose the greatest problem on high voltage transmission lines, on transformers, and inside electrical substations.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germain, Shawn

    Nuclear Power Plant (NPP) refueling outages create some of the most challenging activities the utilities face in both tracking and coordinating thousands of activities in a short period of time. Other challenges, including nuclear safety concerns arising from atypical system configurations and resource allocation issues, can create delays and schedule overruns, driving up outage costs. Today the majority of the outage communication is done using processes that do not take advantage of advances in modern technologies that enable enhanced communication, collaboration and information sharing. Some of the common practices include: runners that deliver paper-based requests for approval, radios, telephones, desktopmore » computers, daily schedule printouts, and static whiteboards that are used to display information. Many gains have been made to reduce the challenges facing outage coordinators; however; new opportunities can be realized by utilizing modern technological advancements in communication and information tools that can enhance the collective situational awareness of plant personnel leading to improved decision-making. Ongoing research as part of the Light Water Reactor Sustainability Program (LWRS) has been targeting NPP outage improvement. As part of this research, various applications of collaborative software have been demonstrated through pilot project utility partnerships. Collaboration software can be utilized as part of the larger concept of Computer-Supported Cooperative Work (CSCW). Collaborative software can be used for emergent issue resolution, Outage Control Center (OCC) displays, and schedule monitoring. Use of collaboration software enables outage staff and subject matter experts (SMEs) to view and update critical outage information from any location on site or off.« less

  20. NOAA Weather Radio - SAME

    Science.gov Websites

    Station Search Coverage Maps Outages View Outages Report Outages Information General Information Receiver Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME FIPS (Federal Information Processing Standards) code changes and / or SAME location code changes

  1. NOAA Weather Radio

    Science.gov Websites

    Station Search Coverage Maps Outages View Outages Report Outages Information General Information Receiver Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME Search For Go NWS All NOAA Frequently Asked Questions This site offers a wealth of information on NOAA

  2. NOAA Weather Radio - All Hazards

    Science.gov Websites

    Station Search Coverage Maps Outages View Outages Report Outages Information General Information Receiver Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME Weather Service (NWS) warnings, watches, forecasts and other non-weather related hazard information 24

  3. A GPS coverage model

    NASA Technical Reports Server (NTRS)

    Skidmore, Trent A.

    1994-01-01

    The results of several case studies using the Global Positioning System coverage model developed at Ohio University are summarized. Presented are results pertaining to outage area, outage dynamics, and availability. Input parameters to the model include the satellite orbit data, service area of interest, geometry requirements, and horizon and antenna mask angles. It is shown for precision-landing Category 1 requirements that the planned GPS 21 Primary Satellite Constellation produces significant outage area and unavailability. It is also shown that a decrease in the user equivalent range error dramatically decreases outage area and improves the service availability.

  4. Comparison and validation of statistical methods for predicting power outage durations in the event of hurricanes.

    PubMed

    Nateghi, Roshanak; Guikema, Seth D; Quiring, Steven M

    2011-12-01

    This article compares statistical methods for modeling power outage durations during hurricanes and examines the predictive accuracy of these methods. Being able to make accurate predictions of power outage durations is valuable because the information can be used by utility companies to plan their restoration efforts more efficiently. This information can also help inform customers and public agencies of the expected outage times, enabling better collective response planning, and coordination of restoration efforts for other critical infrastructures that depend on electricity. In the long run, outage duration estimates for future storm scenarios may help utilities and public agencies better allocate risk management resources to balance the disruption from hurricanes with the cost of hardening power systems. We compare the out-of-sample predictive accuracy of five distinct statistical models for estimating power outage duration times caused by Hurricane Ivan in 2004. The methods compared include both regression models (accelerated failure time (AFT) and Cox proportional hazard models (Cox PH)) and data mining techniques (regression trees, Bayesian additive regression trees (BART), and multivariate additive regression splines). We then validate our models against two other hurricanes. Our results indicate that BART yields the best prediction accuracy and that it is possible to predict outage durations with reasonable accuracy. © 2011 Society for Risk Analysis.

  5. Verification and Enhancement of VIIRS Day-Night Band Power Outage Detection Product

    NASA Astrophysics Data System (ADS)

    Burke, A.; Schultz, L. A.; Omitaomu, O.; Molthan, A.; Cole, T.; Griffin, R.

    2017-12-01

    The NASA SPoRT (Short-term Prediction Research and Transition) Center has collaborated with scientists at NASA Goddard Space Flight Center to create a power outage detection product from radiance data obtained by the VIIRS (Visible Infrared Imaging Radiometer Suite) sensor aboard the Suomi-NPP satellite. This product uses a composite of pre-event radiance values from the VIIRS Day-Night Band to establish a baseline of "normal" nighttime lights for a study area. Then, after a severe weather event or other disaster, post-event images are compared to the composite to generate a percent-of-normal radiance product to identify areas that are experiencing outages and to aid in disaster response and monitor recovery. This project will use ground-truth county-level outage data provided by Oak Ridge National Laboratory (ORNL) in order validate the product and to establish a percent-of-normal threshold for identifying power outages. Once a threshold is found, ORNL's LandScan Global population data will be combined with the product to estimate how many electrical customers are being affected by power outages after a disaster. Two case studies will be explored to examine power outage recovery after severe weather events, including Hurricane Matthew from 2016 and the Washington D.C. Derecho event of 2012.

  6. Advanced Outage and Control Center: Strategies for Nuclear Plant Outage Work Status Capabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregory Weatherby

    The research effort is a part of the Light Water Reactor Sustainability (LWRS) Program. LWRS is a research and development program sponsored by the Department of Energy, performed in close collaboration with industry to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. The LWRS Program serves to help the US nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. The Outage Control Center (OCC) Pilot Project was directed at carrying out the applied researchmore » for development and pilot of technology designed to enhance safe outage and maintenance operations, improve human performance and reliability, increase overall operational efficiency, and improve plant status control. Plant outage management is a high priority concern for the nuclear industry from cost and safety perspectives. Unfortunately, many of the underlying technologies supporting outage control are the same as those used in the 1980’s. They depend heavily upon large teams of staff, multiple work and coordination locations, and manual administrative actions that require large amounts of paper. Previous work in human reliability analysis suggests that many repetitive tasks, including paper work tasks, may have a failure rate of 1.0E-3 or higher (Gertman, 1996). With between 10,000 and 45,000 subtasks being performed during an outage (Gomes, 1996), the opportunity for human error of some consequence is a realistic concern. Although a number of factors exist that can make these errors recoverable, reducing and effectively coordinating the sheer number of tasks to be performed, particularly those that are error prone, has the potential to enhance outage efficiency and safety. Additionally, outage management requires precise coordination of work groups that do not always share similar objectives. Outage managers are concerned with schedule and cost, union workers are concerned with performing work that is commensurate with their trade, and support functions (safety, quality assurance, and radiological controls, etc.) are concerned with performing the work within the plants controls and procedures. Approaches to outage management should be designed to increase the active participation of work groups and managers in making decisions that closed the gap between competing objectives and the potential for error and process inefficiency.« less

  7. NOAA Weather Radio - Voice of NWS

    Science.gov Websites

    Station Search Coverage Maps Outages View Outages Report Outages Information General Information Receiver Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME information 24 hours a day. Known as the "voice of the National Weather Service," NWR is provided as

  8. 47 CFR 4.5 - Definitions of outage, special offices and facilities, and 911 special facilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... facilities, and 911 special facilities. 4.5 Section 4.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION... Definitions of outage, special offices and facilities, and 911 special facilities. (a) Outage is defined as a... government facilities.” 911 special facilities are addressed separately in paragraph (e) of this section. (c...

  9. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS....7 Definitions of metrics used to determine the general outage-reporting threshold criteria. (a...

  10. Economic costs of electrical system instability and power outages caused by snakes on the Island of Guam

    USGS Publications Warehouse

    Fritts, T.H.

    2002-01-01

    The Brown Tree Snake, Boiga irregularis, is an introduced species on Guam where it causes frequent electrical power outages. The snake's high abundance, its propensity for climbing, and use of disturbed habitats all contribute to interruption of Guam's electrical service and the activities that depend on electrical power. Snakes have caused more than 1600 power outages in the 20-yr period of 1978–1997 and most recently nearly 200 outages per year. Single outages spanning the entire island and lasting 8 or more hours are estimated to cost in excess of $3,000,000 in lost productivity, but the costs of outages that involve only parts of the island or those of shorter durations are more difficult to quantify. Costs to the island's economy have exceeded $4.5 M $4.5M"> per year over a 7-yr period without considering repair costs, damage to electrical equipment, and lost revenues. Snakes pose the greatest problem on high voltage transmission lines, on transformers, and inside electrical substations.

  11. Guidelines for Implementation of an Advanced Outage Control Center to Improve Outage Coordination, Problem Resolution, and Outage Risk Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    St. Germain, Shawn W.; Farris, Ronald K.; Whaley, April M.

    This research effort is a part of the Light-Water Reactor Sustainability (LWRS) Program, which is a research and development (R&D) program sponsored by Department of Energy (DOE) and performed in close collaboration with industry R&D programs that provide the technical foundations for licensing and managing the long-term, safe, and economical operation of current nuclear power plants. The LWRS program serves to help the U.S. nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. The purpose of this research is to improve management of nuclear powermore » plant (NPP) outages through the development of an advanced outage control center (AOCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This technical report for industry implementation outlines methods and considerations for the establishment of an AOCC. This report provides a process for implementation of a change management plan, evaluation of current outage processes, the selection of technology, and guidance for the implementation of the selected technology. Methods are presented for both adoption of technologies within an existing OCC and for a complete OCC replacement, including human factors considerations for OCC design and setup.« less

  12. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Use of natural gas or petroleum for certain unanticipated... Natural Gas or Petroleum for Emergency and Unanticipated Equipment Outage Purposes § 501.191 Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies defined in section...

  13. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Use of natural gas or petroleum for certain unanticipated... Natural Gas or Petroleum for Emergency and Unanticipated Equipment Outage Purposes § 501.191 Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies defined in section...

  14. 77 FR 3543 - Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-24

    ... discuss the results of a circumstance in which there is a CBOE System outage or other interruption of... Exchange proposes to add a stipulation that in the event of a CBOE System outage or other interruption of... has twenty trading days, but a CBOE System outage occurs for one-half of one trading day, and a TPH...

  15. As assessment of power system vulnerability to release of carbon fibers during commercial aviation accidents

    NASA Technical Reports Server (NTRS)

    Larocque, G. R.

    1980-01-01

    The vulnerability of a power distribution system in Bedford and Lexington, Massachusetts to power outages as a result of exposure to carbon fibers released in a commercial aviation accident in 1993 was examined. Possible crash scenarios at Logan Airport based on current operational data and estimated carbon fiber usage levels were used to predict exposure levels and occurrence probabilities. The analysis predicts a mean time between carbon fiber induced power outages of 2300 years with an expected annual consequence of 0.7 persons losing power. In comparison to historical outage data for the system, this represents a 0.007% increase in outage rate and 0.07% increase in consequence.

  16. Disparities in nuclear power plant performance in the United States and the Federal Republic of Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, K.F.; Winje, D.K.

    This report presents data comparing the performance of light water reactors in the United States and the Federal Republic of Germany (FRG). The comparisons are made for the years 1980-1983 and include 21 Westinghouse Pressurized Water Reactors (PWRs), 22 General Electric Boiling Water Reactors (BWRs) in the US; and 6 Kraftwerk Union (KWU) PWRs and 4 KWJ BWRs in the FRG. Data on capacity losses are presented in a disaggregated form for scheduled outages, forced outages, and regulatory imposed outages. Further, within the scheduled and forced outages, the data is subdivided into losses associated with the nuclear island, the balancemore » of plant, or other causes.« less

  17. Verification and Enhancement of VIIRS Day-Night Band (DNB) Power Outage Detection Product

    NASA Technical Reports Server (NTRS)

    Burke, Angela; Schultz, Lori A.; Omitaomu, Olufemi; Molthan, Andrew L.; Cole, Tony; Griffin, Robert

    2017-01-01

    This case study of Hurricane Matthew (October 2016) uses the NASA Short-Term Prediction Research and Transition (SPoRT) Center DNB power outage product (using GSFC VIIRS DNB preliminary Black Marble product, Roman et al.. 2017) and 2013 LandScan Global population data to look for correlations between the post-event %-of-normal radiance and the utility company-reported outage numbers (obtained from EAGLE-1).

  18. Refinery Outages

    EIA Publications

    2017-01-01

    EIA's latest analysis of planned refinery outages during the first half of 2017 finds that such outages are not expected to cause a shortfall in the supply of petroleum products including gasoline, jet fuel, and distillate fuel, relative to expected demand, either nationally or within any U.S. region. This result occurs notwithstanding the current high level of U.S. gasoline demand, which in 2016 was as high as or higher than in any past year.

  19. Hybrid Cascading Outage Analysis of Extreme Events with Optimized Corrective Actions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vallem, Mallikarjuna R.; Vyakaranam, Bharat GNVSR; Holzer, Jesse T.

    2017-10-19

    Power system are vulnerable to extreme contingencies (like an outage of a major generating substation) that can cause significant generation and load loss and can lead to further cascading outages of other transmission facilities and generators in the system. Some cascading outages are seen within minutes following a major contingency, which may not be captured exclusively using the dynamic simulation of the power system. The utilities plan for contingencies either based on dynamic or steady state analysis separately which may not accurately capture the impact of one process on the other. We address this gap in cascading outage analysis bymore » developing Dynamic Contingency Analysis Tool (DCAT) that can analyze hybrid dynamic and steady state behavior of the power system, including protection system models in dynamic simulations, and simulating corrective actions in post-transient steady state conditions. One of the important implemented steady state processes is to mimic operator corrective actions to mitigate aggravated states caused by dynamic cascading. This paper presents an Optimal Power Flow (OPF) based formulation for selecting corrective actions that utility operators can take during major contingency and thus automate the hybrid dynamic-steady state cascading outage process. The improved DCAT framework with OPF based corrective actions is demonstrated on IEEE 300 bus test system.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garlapati, Shravan K; Kuruganti, Phani Teja; Buehrer, Richard M

    The deployment of advanced metering infrastructure by the electric utilities poses unique communication challenges, particularly as the number of meters per aggregator increases. During a power outage, a smart meter tries to report it instantaneously to the electric utility. In a densely populated residential/industrial locality, it is possible that a large number of smart meters simultaneously try to get access to the communication network to report the power outage. If the number of smart meters is very high of the order of tens of thousands (metropolitan areas), the power outage data flooding can lead to Random Access CHannel (RACH) congestion.more » Several utilities are considering the use of cellular network for smart meter communications. In 3G/4G cellular networks, RACH congestion not only leads to collisions, retransmissions and increased RACH delays, but also has the potential to disrupt the dedicated traffic flow by increasing the interference levels (3G CDMA). In order to overcome this problem, in this paper we propose a Time Hierarchical Scheme (THS) that reduces the intensity of power outage data flooding and power outage reporting delay by 6/7th, and 17/18th when compared to their respective values without THS. Also, we propose an Optimum Transmission Rate Adaptive (OTRA) MAC to optimize the latency in power outage data collection. The analysis and simulation results presented in this paper show that both the OTRA and THS features of the proposed MAC results in a Power Outage Data Collection Latency (PODCL) that is 1/10th of the 4G LTE PODCL.« less

  1. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study☆

    PubMed Central

    Haidari, Leila A.; Brown, Shawn T.; Wedlock, Patrick; Connor, Diana L.; Spiker, Marie; Lee, Bruce Y.

    2017-01-01

    Background Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Methods Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as “electric refrigerators”) at different locations in the supply chain under various circumstances. Results At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Conclusion Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. PMID:28364935

  2. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study.

    PubMed

    Haidari, Leila A; Brown, Shawn T; Wedlock, Patrick; Connor, Diana L; Spiker, Marie; Lee, Bruce Y

    2017-04-19

    Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. Copyright © 2017. Published by Elsevier Ltd.

  3. Outage Analysis of Dual-hop Cognitive Networks with Relay Selection over Nakagami-m Fading Environment

    NASA Astrophysics Data System (ADS)

    Zhang, Zongsheng; Pi, Xurong

    2014-09-01

    In this paper, we investigate the outage performance of decode-and-forward cognitive relay networks for Nakagami-m fading channels, with considering both best relay selection and interference constraints. Focusing on the relay selection and making use of the underlay cognitive approach, an exact closed-form outage probability expression is derived in an independent, non-identical distributed Nakagami-m environment. The closed-form outage probability provides an efficient means to evaluate the effects of the maximum allowable interference power, number of cognitive relays, and channel conditions between the primary user and cognitive users. Finally, we present numerical results to validate the theory analysis. Moreover, from the simulation results, we obtain that the system can obtain the full diversity.

  4. Cost of Lightning Strike Related Outages of Visual Navigational Aids at Airports in the United States

    NASA Astrophysics Data System (ADS)

    Rakas, J.; Nikolic, M.; Bauranov, A.

    2017-12-01

    Lightning storms are a serious hazard that can cause damage to vital human infrastructure. In aviation, lightning strikes cause outages to air traffic control equipment and facilities that result in major disruptions in the network, causing delays and financial costs measured in the millions of dollars. Failure of critical systems, such as Visual Navigational Aids (Visual NAVAIDS), are particularly dangerous since NAVAIDS are an essential part of landing procedures. Precision instrument approach, an operation utilized during the poor visibility conditions, utilizes several of these systems, and their failure leads to holding patterns and ultimately diversions to other airports. These disruptions lead to both ground and airborne delay. Accurate prediction of these outages and their costs is a key prerequisite for successful investment planning. The air traffic management and control sector need accurate information to successfully plan maintenance and develop a more robust system under the threat of increasing lightning rates. To analyze the issue, we couple the Remote Monitoring and Logging System (RMLS) database and the Aviation System Performance Metrics (ASPM) databases to identify lightning-induced outages, and connect them with weather conditions, demand and landing runway to calculate the total delays induced by the outages, as well as the number of cancellations and diversions. The costs are then determined by calculating direct costs to aircraft operators and costs of passengers' time for delays, cancellations and diversions. The results indicate that 1) not all NAVAIDS are created equal, and 2) outside conditions matter. The cost of an outage depends on the importance of the failed system and the conditions that prevailed before, during and after the failure. The outage that occurs during high demand and poor weather conditions is more likely to result in more delays and higher costs.

  5. Power Outages

    MedlinePlus

    ... of the items you need that rely on electricity. Talk to your medical provider about a power outage plan for medical devices powered by electricity and refrigerated medicines. Find out how long medication ...

  6. Coping with a MEDLIB-L service outage

    PubMed Central

    Brown, Christine D.; MacCall, Steven

    2001-01-01

    Objective: The study assessed the coping strategies of MEDLIB-L subscribers during an unexpected disruption in the list's service. Methods: An online survey of MEDLIB-L subscribers was performed following a six-day service outage in August 1999. Results: Respondents' information needs resulted in two distinct coping strategies. Subscribers without a recognized information need or an information need determined to be not pressing coped by waiting out the interruption. Subscribers with pressing information needs turned to alternative methods of resolving these needs. Conclusions: While most respondents missed the list and the assistance that it provided, many did not feel that the outage required significant coping strategies. The outage was viewed as a “minor stressor” and did not require secondary-level assessment of the availability and suitability of alternative resources. PMID:11837260

  7. Characterization of Nighttime Light Variability over the Southeastern United States

    NASA Astrophysics Data System (ADS)

    Cole, T.; Molthan, A.; Schultz, L. A.

    2015-12-01

    Severe meteorological events such as thunderstorms, tropical cyclones and winter ice storms often produce prolonged, widespread power outages affecting large populations and regions. The spatial impact of these events can extend from relatively rural, small towns (i.e. November 17, 2013 Washington, IL EF-4 tornado) to a series of adjoined states (i.e. April 27, 2011 severe weather outbreak) to entire regions (i.e. 2012 Hurricane Sandy) during their lifespans. As such, affected populations can vary greatly, depending on the event's intensity, location and duration. Actions taken by disaster response agencies like FEMA, the American Red Cross and NOAA to provide support to communities during the recovery process need accurate and timely information on the extent and location(s) of power disruption. This information is often not readily available to these agencies given communication interruptions, independent storm damage reports and other response-inhibiting factors. VIIRS DNB observations which provide daily, nighttime measurements of light sources can be used to detect and monitor power outages caused by these meteorological disaster events. To generate such an outage product, normal nighttime light variability must be analyzed and understood at varying spatial scales (i.e individual pixels, clustered land uses/covers, entire city extents). The southeastern portion of the United States serves as the study area in which the mean, median and standard deviation of nighttime lights are examined over numerous temporal periods (i.e. monthly, seasonally, annually, inter-annually). It is expected that isolated pixels with low population density (rural) will have tremendous variability in which an outage "signal" is difficult to detect. Small towns may have more consistent lighting (over a few pixels), making it easier to identify outages and reductions. Finally, large metropolitan areas may be the most "stable" light source, but the entire area may rarely experience a complete outage. The goal is to determine the smallest spatial scale in which an outage can be detected. Presented work will highlight nighttime light variability over the southeastern U.S. which will serve as a baseline for the production of a near real-time power outage product.

  8. Operations and Maintenance May Newsletter | Poster

    Cancer.gov

    Occurring without notice, unscheduled utility outages (mainly electrical) are abrupt and create a nuisance. During an unscheduled electrical power outage, the Operations and Maintenance (O&M) department will monitor stand-by generators for proper operation.

  9. Outage management and health physics issue, 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    2007-05-15

    The focus of the May-June issue is on outage management and health physics. Major articles/reports in this issue include: India: a potential commercial opportunity, a U.S. Department of Commerce Report, by Joe Neuhoff and Justin Rathke; The changing climate for nuclear energy, by Skip Bowman, Nuclear Energy Insitute; Selecting protective clothing, by J. Mark Price, Southern California Edison; and Succssful refurbishment outage, by Sudesh K. Gambhir, Omaha Public Power District. Industry innovation articles in this issue are: Containment radiation monitoring spiking, by Michael W. Lantz and Robert Routolo, Arizona Public Service Company; Improved outage performance, by Michael Powell and Troymore » Wilfong, Arizona Public Service Company, Palo Verde Nuclear Generating Station; Stop repacking valves and achieve leak-free performance, by Kenneth Hart, PPL Susquehanna LLC; and Head assembly upgrade package, by Timothy Petit, Dominion Nuclear.« less

  10. Using Predictive Analytics to Predict Power Outages from Severe Weather

    NASA Astrophysics Data System (ADS)

    Wanik, D. W.; Anagnostou, E. N.; Hartman, B.; Frediani, M. E.; Astitha, M.

    2015-12-01

    The distribution of reliable power is essential to businesses, public services, and our daily lives. With the growing abundance of data being collected and created by industry (i.e. outage data), government agencies (i.e. land cover), and academia (i.e. weather forecasts), we can begin to tackle problems that previously seemed too complex to solve. In this session, we will present newly developed tools to aid decision-support challenges at electric distribution utilities that must mitigate, prepare for, respond to and recover from severe weather. We will show a performance evaluation of outage predictive models built for Eversource Energy (formerly Connecticut Light & Power) for storms of all types (i.e. blizzards, thunderstorms and hurricanes) and magnitudes (from 20 to >15,000 outages). High resolution weather simulations (simulated with the Weather and Research Forecast Model) were joined with utility outage data to calibrate four types of models: a decision tree (DT), random forest (RF), boosted gradient tree (BT) and an ensemble (ENS) decision tree regression that combined predictions from DT, RF and BT. The study shows that the ENS model forced with weather, infrastructure and land cover data was superior to the other models we evaluated, especially in terms of predicting the spatial distribution of outages. This research has the potential to be used for other critical infrastructure systems (such as telecommunications, drinking water and gas distribution networks), and can be readily expanded to the entire New England region to facilitate better planning and coordination among decision-makers when severe weather strikes.

  11. Designing an Alternate Mission Operations Control Room

    NASA Technical Reports Server (NTRS)

    Montgomery, Patty; Reeves, A. Scott

    2014-01-01

    The Huntsville Operations Support Center (HOSC) is a multi-project facility that is responsible for 24x7 real-time International Space Station (ISS) payload operations management, integration, and control and has the capability to support small satellite projects and will provide real-time support for SLS launches. The HOSC is a service-oriented/ highly available operations center for ISS payloads-directly supporting science teams across the world responsible for the payloads. The HOSC is required to endure an annual 2-day power outage event for facility preventive maintenance and safety inspection of the core electro-mechanical systems. While complete system shut-downs are against the grain of a highly available sub-system, the entire facility must be powered down for a weekend for environmental and safety purposes. The consequence of this ground system outage is far reaching: any science performed on ISS during this outage weekend is lost. Engineering efforts were focused to maximize the ISS investment by engineering a suitable solution capable of continuing HOSC services while supporting safety requirements. The HOSC Power Outage Contingency (HPOC) System is a physically diversified compliment of systems capable of providing identified real-time services for the duration of a planned power outage condition from an alternate control room. HPOC was designed to maintain ISS payload operations for approximately three continuous days during planned HOSC power outages and support a local Payload Operations Team, International Partners, as well as remote users from the alternate control room located in another building.

  12. Designing an Alternate Mission Operations Control Room

    NASA Technical Reports Server (NTRS)

    Montgomery, Patty; Reeves, A. Scott

    2014-01-01

    The Huntsville Operations Support Center (HOSC) is a multi-project facility that is responsible for 24x7 real-time International Space Station (ISS) payload operations management, integration, and control and has the capability to support small satellite projects and will provide real-time support for SLS launches. The HOSC is a serviceoriented/ highly available operations center for ISS payloads-directly supporting science teams across the world responsible for the payloads. The HOSC is required to endure an annual 2-day power outage event for facility preventive maintenance and safety inspection of the core electro-mechanical systems. While complete system shut-downs are against the grain of a highly available sub-system, the entire facility must be powered down for a weekend for environmental and safety purposes. The consequence of this ground system outage is far reaching: any science performed on ISS during this outage weekend is lost. Engineering efforts were focused to maximize the ISS investment by engineering a suitable solution capable of continuing HOSC services while supporting safety requirements. The HOSC Power Outage Contingency (HPOC) System is a physically diversified compliment of systems capable of providing identified real-time services for the duration of a planned power outage condition from an alternate control room. HPOC was designed to maintain ISS payload operations for approximately three continuous days during planned HOSC power outages and support a local Payload Operations Team, International Partners, as well as remote users from the alternate control room located in another building. This paper presents the HPOC architecture and lessons learned during testing and the planned maiden operational commissioning. Additionally, this paper documents the necessity of an HPOC capability given the unplanned HOSC Facility power outage on April 27th, 2011, as a result of the tornado outbreak that damaged the electrical grid to such a degree that significantly inhibited the Tennessee Valley Authority's ability to transmit electricity throughout the North Alabama region.

  13. Performance of Trellis Coded 256 QAM super-multicarrier modem VLSI's for SDH interface outage-free digital microwave radio

    NASA Astrophysics Data System (ADS)

    Aikawa, Satoru; Nakamura, Yasuhisa; Takanashi, Hitoshi

    1994-02-01

    This paper describes the performance of an outage free SXH (Synchronous Digital Hierarchy) interface 256 QAM modem. An outage free DMR (Digital Microwave Radio) is achieved by a high coding gain trellis coded SPORT QAM and Super Multicarrier modem. A new frame format and its associated circuits connect the outage free modem to the SDH interface. The newly designed VLSI's are key devices for developing the modem. As an overall modem performance, BER (bit error rate) characteristics and equipment signatures are presented. A coding gain of 4.7 dB (at a BER of 10(exp -4)) is obtained using SPORT 256 QAM and Viterbi decoding. This coding gain is realized by trellis coding as well as by increasing of transmission rate. Roll-off factor is decreased to maintain the same frequency occupation and modulation level as ordinary SDH 256 QAM modern.

  14. Code Development and Assessment for Reactor Outage Thermal-Hydraulic and Safety Analysis - Midloop Operation with Loss of Residual Heat Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, Thomas K.S.; Ko, F.-K

    Although only a few percent of residual power remains during plant outages, the associated risk of core uncovery and corresponding fuel overheating has been identified to be relatively high, particularly under midloop operation (MLO) in pressurized water reactors. However, to analyze the system behavior during outages, the tools currently available, such as RELAP5, RETRAN, etc., cannot easily perform the task. Therefore, a medium-sized program aiming at reactor outage simulation and evaluation, such as MLO with the loss of residual heat removal (RHR), was developed. All important thermal-hydraulic processes involved during MLO with the loss of RHR will be properly simulatedmore » by the newly developed reactor outage simulation and evaluation (ROSE) code. Important processes during MLO with loss of RHR involve a pressurizer insurge caused by the hot-leg flooding, reflux condensation, liquid holdup inside the steam generator, loop-seal clearance, core-level depression, etc. Since the accuracy of the pressure distribution from the classical nodal momentum approach will be degraded when the system is stratified and under atmospheric pressure, the two-region approach with a modified two-fluid model will be the theoretical basis of the new program to analyze the nuclear steam supply system during plant outages. To verify the analytical model in the first step, posttest calculations against the closed integral midloop experiments with loss of RHR were performed. The excellent simulation capacity of the ROSE code against the Institute of Nuclear Energy Research Integral System Test Facility (IIST) test data is demonstrated.« less

  15. Assessment of Critical Events Corridors through Multivariate Cascading Outages Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, Yuri V.; Samaan, Nader A.; Diao, Ruisheng

    2011-10-17

    Massive blackouts of electrical power systems in North America over the past decade has focused increasing attention upon ways to identify and simulate network events that may potentially lead to widespread network collapse. This paper summarizes a method to simulate power-system vulnerability to cascading failures to a supplied set of initiating events synonymously termed as Extreme Events. The implemented simulation method is currently confined to simulating steady state power-system response to a set of extreme events. The outlined method of simulation is meant to augment and provide a new insight into bulk power transmission network planning that at present remainsmore » mainly confined to maintaining power system security for single and double component outages under a number of projected future network operating conditions. Although one of the aims of this paper is to demonstrate the feasibility of simulating network vulnerability to cascading outages, a more important goal has been to determine vulnerable parts of the network that may potentially be strengthened in practice so as to mitigate system susceptibility to cascading failures. This paper proposes to demonstrate a systematic approach to analyze extreme events and identify vulnerable system elements that may be contributing to cascading outages. The hypothesis of critical events corridors is proposed to represent repeating sequential outages that can occur in the system for multiple initiating events. The new concept helps to identify system reinforcements that planners could engineer in order to 'break' the critical events sequences and therefore lessen the likelihood of cascading outages. This hypothesis has been successfully validated with a California power system model.« less

  16. The impact of a large-scale power outage on hemodialysis center operations.

    PubMed

    Abir, Mahshid; Jan, Sophia; Jubelt, Lindsay; Merchant, Raina M; Lurie, Nicole

    2013-12-01

    On June 29, 2012, mid-Atlantic storms resulted in a large-scale power outage affecting up to three million people across multiple (US) states. Hemodialysis centers are dependent on electricity to provide dialysis care to end-stage renal disease patients. The objective of this study was to determine how the power outage impacted operations in a sample of hemodialysis centers in the impacted regions. The sample consisted of all hemodialysis centers located in the District of Columbia and a total of five counties with the largest power losses in West Virginia, Virginia, and Maryland. A semi-structured interview guide was developed, and the charge nurse or supervisor in each facility was interviewed. The survey questions addressed whether their centers lost power, if so, for how long, where their patients received dialysis, whether their centers had backup generators, and if so, whether they had any problems operating them, and whether their center received patients from other centers if they had power. Calls were placed to 90 dialysis centers in the sampled areas and a 90% response rate was achieved. Overall, hemodialysis operations at approximately 30% (n = 24) of the centers queried were impacted by the power outage. Of the 36 centers that lost power, 31% (n = 11) referred their patients to other dialysis centers, 22% (n = 8) accommodated their patients during a later shift or on a different day; the rest of the centers either experienced brief power outages that did not affect operations or experienced a power outage on days that the center is usually closed. Some centers in the study cohort reported receiving patients from other centers for dialysis 33% (n = 27). Thirty-two percent (n = 26) of the centers queried had backup generators on site. Eleven percent (n = 4) of the centers experiencing power outages reported that backup generators were brought in by their parent companies. Comprehensive emergency planning for dialysis centers should include provisions for having backup generators on site, having plans in place for the timely delivery of a generator during a power outage, or having predesignated backup dialysis centers for patients to receive dialysis during emergencies. Most dialysis centers surveyed in this study were able to sustain continuity of care by implementing such pre-existing emergency plans.

  17. Real-time Social Media Data Analytics for Situational Awareness of the Electric Grid

    NASA Astrophysics Data System (ADS)

    Mao, H.; Chinthavali, S.; Lee, S.; Shankar, M.; Thiagarajan, S.

    2016-12-01

    With the increasing frequency of extreme events due to climate change, wide area situational awareness (SA) of the electric grid has become a primary need for federal agencies like DOE,FEMA etc. for emergency preparedness and recovery purposes. While several sensor feeds from Genscape, GridEye, PMUs provide a comprehensive view of the transmission grid, national-scale situational awareness tools are still relying on utility websites for outage information at a distribution level. The inconsistency and the variety in outage website's data formats makes this approach unreliable and also incurs huge software maintenance costs. Social media has emerged as a great medium for the utilities to share outage information with their customers. Despite their potential usefulness, extracting relevant data from these social media data-streams is challenging due to the inherent noise and irrelevant information such as tips to customers during storms, marketing, etc. In this study, we implement a practical and novel machine learning based data-analytics pipeline (Fig 1) for SA, which extracts real-time tweets from around 300 utility companies, processes these tweets using keyword filtering and Naïve-Bayes text classifier trained using supervised learning techniques to detect only relevant tweets. We validated the results by comparing it with the results identified by a human analyst for a period of 48 hours, and it showed around 98.3% accuracy. In addition to the tweets posted by utility companies, millions of twitter users, who are considered as human "social sensors", report power outages online. Therefore, we use Twitter Streaming API to extract real-time tweets containing keywords such as "power outage", "blackout", and "power cuts". An advanced natural language processing technique is proposed to identify the geo-locations associated with this power outage data. The detected tweets are visualized as a color-coded state and a county US map based on the number of outage tweets posted. Therefore, by analyzing a large amount of tweets posted by utilities and the general public, our approach can detect real-time power outages at a national-scale. This framework has been integrated into existing SA tools such as VERDE, EARSS and EAGLE-I, which is deployed by the Oak Ridge National Laboratory for the DOE.

  18. Olkiluoto 1 and 2 - Plant efficiency improvement and lifetime extension-project (PELE) implemented during outages 2010 and 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kosonen, M.; Hakola, M.

    2012-07-01

    Teollisuuden Voima Oyj (TVO) is a non-listed public company founded in 1969 to produce electricity for its stakeholders. TVO is the operator of the Olkiluoto nuclear power plant. TVO follows the principle of continuous improvement in the operation and maintenance of the Olkiluoto plant units. The PELE project (Plant Efficiency Improvement and Lifetime Extension), mainly completed during the annual outages in 2010 and 2011, and forms one part of the systematic development of Olkiluoto units. TVO maintains a long-term development program that aims at systematically modernizing the plant unit systems and equipment based on the latest technology. According to themore » program, the Olkiluoto 1 and Olkiluoto 2 plant units are constantly renovated with the intention of keeping them safe and reliable, The aim of the modernization projects is to improve the safety, reliability, and performance of the plant units. PELE project at Olkiluoto 1 was done in 2010 and at Olkiluoto 2 in 2011. The outage length of Olkiluoto 1 was 26 d 12 h 4 min and Olkiluoto 2 outage length was 28 d 23 h 46 min. (Normal service-outage is about 14 days including refueling and refueling-outage length is about seven days. See figure 1) The PELE project consisted of several single projects collected into one for coordinated project management. Some of the main projects were as follows: - Low pressure turbines: rotor, stator vane, casing and turbine instrumentation replacement. - Replacement of Condenser Cooling Water (later called seawater pumps) pumps - Replacement of inner isolation valves on the main steam lines. - Generator and the generator cooling system replacement. - Low voltage switchgear replacement. This project will continue during future outages. PELE was a success. 100 TVO employees and 1500 subcontractor employees participated in the project. The execution of the PELE projects went extremely well during the outages. The replacement of the low pressure turbines and seawater pumps improved the efficiency of the plant units, and a power increase of nearly 20 MW was achieved at both plant units. PELE wonderfully manifests one of the strategic goals of our company; developing the competence of our in-house personnel by working in projects. (authors)« less

  19. A computer assisted intelligent storm outage evaluator for power distribution systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balakrishnan, R.; Pahwa, A.

    1990-07-01

    The lower voltage part of the power distribution system (primary and secondary sub-systems) does not have the provision for real-time status feedback, and as a result evaluation of outages is an extremely difficult task, especially during system emergencies caused by tornadoes and ice-storms. In this paper, a knowledge based approach is proposed for evaluation of storm related outages in the distribution systems. At the outset, binary voltage sensors capable of transmitting the real-time voltage on/off symptoms are recommended to be installed at strategic locations in the distribution system.

  20. Application of Hybrid Geo-Spatially Granular Fragility Curves to Improve Power Outage Predictions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fernandez, Steven J; Allen, Melissa R; Omitaomu, Olufemi A

    2014-01-01

    Fragility curves depict the relationship between a weather variable (wind speed, gust speed, ice accumulation, precipitation rate) and the observed outages for a targeted infrastructure network. This paper describes an empirical study of the county by county distribution of power outages and one minute weather variables during Hurricane Irene with the objective of comparing 1) as built fragility curves (statistical approach) to engineering as designed (bottom up) fragility curves for skill in forecasting outages during future hurricanes; 2) county specific fragility curves to find examples of significant deviation from average behavior; and 3) the engineering practices of outlier counties tomore » suggest future engineering studies of robustness. Outages in more than 90% of the impacted counties could be anticipated through an average or generic fragility curve. The remaining counties could be identified and handled as exceptions through geographic data sets. The counties with increased or decreased robustness were characterized by terrain more or less susceptible to persistent flooding in areas where above ground poles located their foundations. Land use characteristics of the area served by the power distribution system can suggest trends in the as built power grid vulnerabilities to extreme weather events that would be subjects for site specific studies.« less

  1. Status of the steam generator tube circumferential ODSCC degradation experienced at the Doel 4 plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roussel, G.

    1997-02-01

    Since the 1991 outage, the Doel Unit 4 nuclear power plant is known to be affected by circumferential outside diameter intergranular stress corrosion cracking at the hot leg tube expansion transition. Extensive non destructive examination inspections have shown the number of tubes affected by this problem as well as the size of the cracks to have been increasing for the three cycles up to 1993. As a result of the high percentage of tubes found non acceptable for continued service after the 1993 in-service inspection, about 1,700 mechanical sleeves were installed in the steam generators. During the 1994 outage, allmore » the tubes sleeved during the 1993 outage were considered as potentially cracked to some extent at the upper hydraulic transition and were therefore not acceptable for continued service. They were subsequently repaired by laser welding. Furthermore all the tubes not sleeved during the 1993 outage were considered as not acceptable for continued service and were repaired by installing laser welded sleeves. During the 1995 outage, some unexpected degradation phenomena were evidenced in the sleeved tubes. This paper summarizes the status of the circumferential ODSCC experienced in the SG tubes of the Doel 4 plant as well as the other connected degradation phenomena.« less

  2. Supporting Disaster Assessment and Response with the VIIRS Day-Night Band

    NASA Technical Reports Server (NTRS)

    Schultz, Lori A.; Cole, Tony; Molthan, Andrew L.

    2015-01-01

    When meteorological or man-made disasters occur, first responders often focus on impacts to the affected population and other human activities. Often, these disasters result in significant impacts to local infrastructure and power, resulting in widespread power outages. For minor events, these power outages are often short-lived, but major disasters often include long-term outages that have a significant impact on wellness, safety, and recovery efforts within the affected areas. Staff at NASA's Short-term Prediction Research and Transition (SPoRT) Center have been investigating the use of the VIIRS day-night band for monitoring power outages that result from significant disasters, and developing techniques to identify damaged areas in near real-time following events. In addition to immediate assessment, the VIIRS DNB can be used to monitor and assess ongoing recovery efforts. In this presentation, we will highlight previous applications of the VIIRS DNB following Superstorm Sandy in 2012, and other applications of the VIIRS DNB to more recent disaster events, including detection of outages following the Moore, Oklahoma tornado of May 2013 and the Chilean earthquake of April 2014. Examples of current products will be shown, along with future work and other goals for supporting disaster assessment and response with VIIRS capabilities.

  3. 76 FR 16240 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ... Standards. The Reliability Standards were designed to prevent instability, uncontrolled separation, or... designed to prevent instability, uncontrolled separation, or cascading outages that adversely impact the... instability, uncontrolled separation, or cascading outages. See NERC Glossary, available at http://www.nerc...

  4. 75 FR 6339 - California Public Utilities Commission Petition for Rulemaking

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-09

    ... (NORS). The CPUC also requests password-protected access to California- specific disruption and outage... ``limited to California-specific disruption and outage data.'' NORS is the Web-based filing system through which certain communications providers submit reports to the Commission of disruptions to communications...

  5. Lights out: Impact of the August 2003 power outage on mortality in New York, NY

    PubMed Central

    Anderson, G. Brooke; Bell, Michelle L.

    2012-01-01

    Background Little is known about how power outages affect health. We investigated mortality effects of the largest US blackout to date, August 14–15, 2003 in New York, NY. Methods We estimated mortality risk in New York, NY, using a generalized linear model with data from 1987–2005. We incorporated possible confounders, including weather and long-term and seasonal mortality trends. Results During the blackout, mortality increased for accidental deaths (122% [95% confidence interval = 28%–287%]) and non-accidental (i.e., disease-related) deaths (25% [12%–41%]), resulting in approximately 90 excess deaths. Increased mortality was not from deaths being advanced by a few days; rather, mortality risk remained slightly elevated through August 2003. Discussion To our knowledge, this is the first analysis of power outages and non-accidental mortality. Understanding the impact of power outages on human health is relevant, given that increased energy demand and climate change are likely to put added strain on power grids. PMID:22252408

  6. Comparison of Aperture Averaging and Receiver Diversity Techniques for Free Space Optical Links in Presence of Turbulence and Various Weather Conditions

    NASA Astrophysics Data System (ADS)

    Kaur, Prabhmandeep; Jain, Virander Kumar; Kar, Subrat

    2014-12-01

    In this paper, we investigate the performance of a Free Space Optic (FSO) link considering the impairments caused by the presence of various weather conditions such as very clear air, drizzle, haze, fog, etc., and turbulence in the atmosphere. Analytic expression for the outage probability is derived using the gamma-gamma distribution for turbulence and accounting the effect of weather conditions using the Beer-Lambert's law. The effect of receiver diversity schemes using aperture averaging and array receivers on the outage probability is studied and compared. As the aperture diameter is increased, the outage probability decreases irrespective of the turbulence strength (weak, moderate and strong) and weather conditions. Similar effects are observed when the number of direct detection receivers in the array are increased. However, it is seen that as the desired level of performance in terms of the outage probability decreases, array receiver becomes the preferred choice as compared to the receiver with aperture averaging.

  7. Spectrum Sharing in an ISM Band: Outage Performance of a Hybrid DS/FH Spread Spectrum System with Beamforming

    NASA Astrophysics Data System (ADS)

    Li, Hanyu; Syed, Mubashir; Yao, Yu-Dong; Kamakaris, Theodoros

    2009-12-01

    This paper investigates spectrum sharing issues in the unlicensed industrial, scientific, and medical (ISM) bands. It presents a radio frequency measurement setup and measurement results in 2.4 GHz. It then develops an analytical model to characterize the coexistence interference in the ISM bands, based on radio frequency measurement results in the 2.4 GHz. Outage performance using the interference model is examined for a hybrid direct-sequence frequency-hopping spread spectrum system. The utilization of beamforming techniques in the system is also investigated, and a simplified beamforming model is proposed to analyze the system performance using beamforming. Numerical results show that beamforming significantly improves the system outage performance. The work presented in this paper provides a quantitative evaluation of signal outages in a spectrum sharing environment. It can be used as a tool in the development process for future dynamic spectrum access models as well as engineering designs for applications in unlicensed bands.

  8. Power Allocation and Outage Probability Analysis for SDN-based Radio Access Networks

    NASA Astrophysics Data System (ADS)

    Zhao, Yongxu; Chen, Yueyun; Mai, Zhiyuan

    2018-01-01

    In this paper, performance of Access network Architecture based SDN (Software Defined Network) is analyzed with respect to the power allocation issue. A power allocation scheme PSO-PA (Particle Swarm Optimization-power allocation) algorithm is proposed, the proposed scheme is subjected to constant total power with the objective of minimizing system outage probability. The entire access network resource configuration is controlled by the SDN controller, then it sends the optimized power distribution factor to the base station source node (SN) and the relay node (RN). Simulation results show that the proposed scheme reduces the system outage probability at a low complexity.

  9. Energy markets : refinery outages can have varying gasoline price impacts, but gaps in federal data limit understanding of impacts.

    DOT National Transportation Integrated Search

    2009-07-01

    In 2008, GAO reported that, with : the exception of the period : following Hurricanes Katrina and : Rita, refinery outages in the United : States did not show discernible : trends in reduced production : capacity, frequency, and location : from 2002 ...

  10. Economic and Environmental Impacts of the Columbia-Snake River Extended Lock Outage

    DOT National Transportation Integrated Search

    2012-03-01

    This reports main objective is to analyze the change in rates and modal costs for shippers, commodity industries and ports prior to, during and after the fifteen week lock outage and to determine the impacts on the environment in the form of energ...

  11. 76 FR 23171 - Electric Reliability Organization Interpretations of Interconnection Reliability Operations and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-26

    ... (MW and MVAR), or system configuration to maintain system stability, acceptable voltage or power flows... identified system conditions to prevent system instability or cascading outages, and protect other facilities... instability, cascading outages, and protect other facilities in response to contingencies. Therefore, a...

  12. Optimal Performance Monitoring of Hybrid Mid-Infrared Wavelength MIMO Free Space Optical and RF Wireless Networks in Fading Channels

    NASA Astrophysics Data System (ADS)

    Schmidt, Barnet Michael

    An optimal performance monitoring metric for a hybrid free space optical and radio-frequency (RF) wireless network, the Outage Capacity Objective Function, is analytically developed and studied. Current and traditional methods of performance monitoring of both optical and RF wireless networks are centered on measurement of physical layer parameters, the most common being signal-to-noise ratio, error rate, Q factor, and eye diagrams, occasionally combined with link-layer measurements such as data throughput, retransmission rate, and/or lost packet rate. Network management systems frequently attempt to predict or forestall network failures by observing degradations of these parameters and to attempt mitigation (such as offloading traffic, increasing transmitter power, reducing the data rate, or combinations thereof) prior to the failure. These methods are limited by the frequent low sensitivity of the physical layer parameters to the atmospheric optical conditions (measured by optical signal-to-noise ratio) and the radio frequency fading channel conditions (measured by signal-to-interference ratio). As a result of low sensitivity, measurements of this type frequently are unable to predict impending failures sufficiently in advance for the network management system to take corrective action prior to the failure. We derive and apply an optimal measure of hybrid network performance based on the outage capacity of the hybrid optical and RF channel, the outage capacity objective function. The objective function provides high sensitivity and reliable failure prediction, and considers both the effects of atmospheric optical impairments on the performance of the free space optical segment as well as the effect of RF channel impairments on the radio frequency segment. The radio frequency segment analysis considers the three most common RF channel fading statistics: Rayleigh, Ricean, and Nakagami-m. The novel application of information theory to the underlying physics of the gamma-gamma optical channel and radio fading channels in determining the joint hybrid channel outage capacity provides the best performance estimate under any given set of operating conditions. It is shown that, unlike traditional physical layer performance monitoring techniques, the objective function based upon the outage capacity of the hybrid channel at any combination of OSNR and SIR, is able to predict channel degradation and failure well in advance of the actual outage. An outage in the information-theoretic definition occurs when the offered load exceeds the outage capacity under the current conditions of OSNR and SIR. The optical channel is operated at the "long" mid-infrared wavelength of 10000 nm. which provides improved resistance to scattering compared to shorter wavelengths such as 1550 nm.

  13. MIMO capacities and outage probabilities in spatially multiplexed optical transport systems.

    PubMed

    Winzer, Peter J; Foschini, Gerard J

    2011-08-15

    With wavelength-division multiplexing (WDM) rapidly nearing its scalability limits, space-division multiplexing (SDM) seems the only option to further scale the capacity of optical transport networks. In order for SDM systems to continue the WDM trend of reducing energy and cost per bit with system capacity, integration will be key to SDM. Since integration is likely to introduce non-negligible crosstalk between multiple parallel transmission paths, multiple-input multiple output (MIMO) signal processing techniques will have to be used. In this paper, we discuss MIMO capacities in optical SDM systems, including related outage considerations which are an important part in the design of such systems. In order to achieve the low-outage standards required for optical transport networks, SDM transponders should be capable of individually addressing, and preferably MIMO processing all modes supported by the optical SDM waveguide. We then discuss the effect of distributed optical noise in MIMO SDM systems and focus on the impact of mode-dependent loss (MDL) on system capacity and system outage. Through extensive numerical simulations, we extract scaling rules for mode-average and mode-dependent loss and show that MIMO SDM systems composed of up to 128 segments and supporting up to 128 modes can tolerate up to 1 dB of per-segment MDL at 90% of the system's full capacity at an outage probability of 10(-4). © 2011 Optical Society of America

  14. 47 CFR 63.71 - Procedures for discontinuance, reduction or impairment of service by domestic carriers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... impairment of service by domestic carriers. 63.71 Section 63.71 Telecommunication FEDERAL COMMUNICATIONS..., REDUCTION, OUTAGE AND IMPAIRMENT OF SERVICE BY COMMON CARRIERS; AND GRANTS OF RECOGNIZED PRIVATE OPERATING AGENCY STATUS Discontinuance, Reduction, Outage and Impairment § 63.71 Procedures for discontinuance...

  15. Air traffic control : good progress on interim replacement for outage-plagued system, but risks can be further reduced

    DOT National Transportation Integrated Search

    1996-10-01

    Certain air traffic control(ATC) centers experienced a series of major outages, : some of which were caused by the Display Channel Complex or DCC-a mainframe : computer system that processes radar and other data into displayable images on : controlle...

  16. 78 FR 6216 - Extension of the Commission's Rules Regarding Outage Reporting to Interconnected Voice Over...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-30

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 4 [PS Docket No. 11-82; DA 12-1962] Extension of the Commission's Rules Regarding Outage Reporting to Interconnected Voice Over Internet Protocol Service Providers and Broadband Internet Service Providers AGENCY: Federal Communications Commission. ACTION: Final...

  17. NOAA Weather Radio - Outage Reporting

    Science.gov Websites

    is not listed at Current Outages, the problem may be possibly be with your receiver. If your NWR receiver is not working properly or you need assistance in programming your NWR receiver, please click here information we may not be able to troubleshoot the problem fully. COVERAGE County Coverage Listings State

  18. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... from an electric power outage and directly effects or would directly effect the public health, safety... curtailment. Note—A utility operating hydroelectric facilities may take into account seasonal fluctuations in storage capacity and shall be permitted to prevent depletion of stored power-producing capacity as deemed...

  19. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... from an electric power outage and directly effects or would directly effect the public health, safety... curtailment. Note—A utility operating hydroelectric facilities may take into account seasonal fluctuations in storage capacity and shall be permitted to prevent depletion of stored power-producing capacity as deemed...

  20. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... from an electric power outage and directly effects or would directly effect the public health, safety... curtailment. Note—A utility operating hydroelectric facilities may take into account seasonal fluctuations in storage capacity and shall be permitted to prevent depletion of stored power-producing capacity as deemed...

  1. 77 FR 25088 - Extension of the Commission's Rules Regarding Outage Reporting to Interconnected Voice Over...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-27

    ... Commission's rules to interconnected Voice over Internet Protocol (VoIP) service providers and defers action... to outages resulting from complete loss of service and only to interconnected VoIP services... obligations of interconnected VoIP service providers. DATES: The rules in this document contain information...

  2. Health Information in Hindi (हिन्दी)

    MedlinePlus

    ... हिन्दी (Hindi) Bilingual PDF Health Information Translations Power Outages - English PDF Power Outages - हिन्दी (Hindi) Bilingual PDF Health Information ... हिन्दी (Hindi) Bilingual PDF Health Information Translations Nuclear Scans Bone Scan - English PDF Bone Scan - हि ...

  3. 40 CFR 52.145 - Visibility protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... limitation in paragraph (d)(2) of this section and shall submit a follow-up written report within 30 days of... periodic reports of compliance with the emission limitation in paragraph (d)(2) of this section which shall... for the control system outage. The report also shall describe the actions taken to avoid the outage...

  4. Outage Performance Analysis of Relay Selection Schemes in Wireless Energy Harvesting Cooperative Networks over Non-Identical Rayleigh Fading Channels †

    PubMed Central

    Do, Nhu Tri; Bao, Vo Nguyen Quoc; An, Beongku

    2016-01-01

    In this paper, we study relay selection in decode-and-forward wireless energy harvesting cooperative networks. In contrast to conventional cooperative networks, the relays harvest energy from the source’s radio-frequency radiation and then use that energy to forward the source information. Considering power splitting receiver architecture used at relays to harvest energy, we are concerned with the performance of two popular relay selection schemes, namely, partial relay selection (PRS) scheme and optimal relay selection (ORS) scheme. In particular, we analyze the system performance in terms of outage probability (OP) over independent and non-identical (i.n.i.d.) Rayleigh fading channels. We derive the closed-form approximations for the system outage probabilities of both schemes and validate the analysis by the Monte-Carlo simulation. The numerical results provide comprehensive performance comparison between the PRS and ORS schemes and reveal the effect of wireless energy harvesting on the outage performances of both schemes. Additionally, we also show the advantages and drawbacks of the wireless energy harvesting cooperative networks and compare to the conventional cooperative networks. PMID:26927119

  5. Outage Performance Analysis of Relay Selection Schemes in Wireless Energy Harvesting Cooperative Networks over Non-Identical Rayleigh Fading Channels.

    PubMed

    Do, Nhu Tri; Bao, Vo Nguyen Quoc; An, Beongku

    2016-02-26

    In this paper, we study relay selection in decode-and-forward wireless energy harvesting cooperative networks. In contrast to conventional cooperative networks, the relays harvest energy from the source's radio-frequency radiation and then use that energy to forward the source information. Considering power splitting receiver architecture used at relays to harvest energy, we are concerned with the performance of two popular relay selection schemes, namely, partial relay selection (PRS) scheme and optimal relay selection (ORS) scheme. In particular, we analyze the system performance in terms of outage probability (OP) over independent and non-identical (i.n.i.d.) Rayleigh fading channels. We derive the closed-form approximations for the system outage probabilities of both schemes and validate the analysis by the Monte-Carlo simulation. The numerical results provide comprehensive performance comparison between the PRS and ORS schemes and reveal the effect of wireless energy harvesting on the outage performances of both schemes. Additionally, we also show the advantages and drawbacks of the wireless energy harvesting cooperative networks and compare to the conventional cooperative networks.

  6. Evaluation of the resilience of a full-scale down-flow hanging sponge reactor to long-term outages at a sewage treatment plant in India.

    PubMed

    Onodera, Takashi; Takayama, Daisuke; Ohashi, Akiyoshi; Yamaguchi, Takashi; Uemura, Shigeki; Harada, Hideki

    2016-10-01

    Resilience to process outages is an essential requirement for sustainable wastewater treatment systems in developing countries. In this study, we evaluated the ability of a full-scale down-flow hanging sponge (DHS) reactor to recover after a 10-day outage. The DHS tested in this study uses polyurethane sponge as packing material. This full-scale DHS reactor has been tested over a period of about 4 years in India with a flow rate of 500 m(3)/day. Water was not supplied to the DHS reactor that was subjected to the 10-day outage; however, the biomass did not dry out because the sponge was able to retain enough water. Soon after the reactor was restarted, a small quantity of biomass, amounting to only 0.1% of the total retained biomass, was eluted. The DHS effluent achieved satisfactory removal of suspended solids, chemical oxygen demand, and ammonium nitrogen within 90, 45, and 90 min, respectively. Conversely, fecal coliforms in the DHS effluent did not reach satisfactory levels within 540 min; instead, the normal levels of fecal coliforms were achieved within 3 days. Overall, the tests demonstrated that the DHS reactor was sufficiently robust to withstand long-term outages and achieved steady state soon after restart. This reinforces the suitability of this technology for developing countries. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Chattanooga Electric Power Board Case Study Distribution Automation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Jim; Melin, Alexander M.; Starke, Michael R.

    In 2009, the U.S. Department of Energy under the American Recovery and Reinvestment Act (ARRA) awarded a grant to the Chattanooga, Tennessee, Electric Power Board (EPB) as part of the Smart Grid Investment Grant Program. The grant had the objective “to accelerate the transformation of the nation’s electric grid by deploying smart grid technologies.” This funding award enabled EPB to expedite the original smart grid implementation schedule from an estimated 10-12 years to 2.5 years. With this funding, EPB invested heavily in distribution automation technologies including installing over 1,200 automated circuit switches and sensors on 171 circuits. For utilities consideringmore » a commitment to distribution automation, there are underlying questions such as the following: “What is the value?” and “What are the costs?” This case study attempts to answer these questions. The primary benefit of distribution automation is increased reliability or reduced power outage duration and frequency. Power outages directly impact customer economics by interfering with business functions. In the past, this economic driver has been difficult to effectively evaluate. However, as this case study demonstrates, tools and analysis techniques are now available. In this case study, the impact on customer costs associated with power outages before and after the implementation of distribution automation are compared. Two example evaluations are performed to demonstrate the benefits: 1) a savings baseline for customers under normal operations1 and 2) customer savings for a single severe weather event. Cost calculations for customer power outages are performed using the US Department of Energy (DOE) Interruption Cost Estimate (ICE) calculator2. This tool uses standard metrics associated with outages and the customers to calculate cost impact. The analysis shows that EPB customers have seen significant reliability improvements from the implementation of distribution automation. Under normal operations, the investment in distribution automation has enabled a 43.5% reduction in annual outage minutes since 2012. This has led to an estimated total savings of $26.8 million per year. Examining a single severe weather event3, the distribution automation was able to restore power to 40,579 (nearly 56%) customers within 1–2 seconds and reduce outage minutes by 29.0%. This saved customers an estimated $23.2 million over the course of the storm.« less

  8. 75 FR 13320 - Florida Power Corporation, et al., Crystal River Unit 3 Nuclear Generating Plant; Environmental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-19

    ... replacement outage that is currently underway at CR-3. In addition to steam generators, other large components (e.g., moisture separators and large heat exchangers) are being replaced during this outage... on the Internet at the NRC Web site: http://www.nrc.gov/reading-rm/adams.html . Persons who do not...

  9. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... call load data for the same day(s) of the week and the same time(s) of day as the outage, and for a... where, for whatever reason, real-time and historic carried call load data are unavailable to the provider, even after a detailed investigation, the provider must determine the carried call load based on...

  10. Energy Resiliency for Marine Corps Logistics Base Production Plant Barstow

    DTIC Science & Technology

    2014-12-01

    13 1. Biomass, Landfill Gas, and Biogas ...value in dollar per kilowatts ($/kW) peak of an outage cost obtained from the CDF curve for a specified duration of the interruption” (Giraldez, Booth...length of outages for inclusion in the VEES calculation, we needed to obtain power interruption and circuit reliability data from PPB’s utility

  11. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.7 Definitions of metrics used to...

  12. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.7 Definitions of metrics used to...

  13. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.7 Definitions of metrics used to...

  14. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.7 Definitions of metrics used to...

  15. Back Propagation Artificial Neural Network and Its Application in Fault Detection of Condenser Failure in Thermo Plant

    NASA Astrophysics Data System (ADS)

    Ismail, Firas B.; Thiruchelvam, Vinesh

    2013-06-01

    Steam condenser is one of the most important equipment in steam power plants. If the steam condenser trips it may lead to whole unit shutdown, which is economically burdensome. Early condenser trips monitoring is crucial to maintain normal and safe operational conditions. In the present work, artificial intelligent monitoring systems specialized in condenser outages has been proposed and coded within the MATLAB environment. The training and validation of the system has been performed using real operational measurements captured from the control system of selected steam power plant. An integrated plant data preparation scheme for condenser outages with related operational variables has been proposed. Condenser outages under consideration have been detected by developed system before the plant control system"

  16. Dose reduction and cost-benefit analysis at Japan`s Tokai No. 2 Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humamoto, Hisao; Suzuki, Seishiro; Taniguchi, Kazufumi

    1995-03-01

    In the Tokai No. 2 power plant of the Japan Atomic Power Company, about 80% of the annual dose equivalent is received during periodic maintenance outages. A project group for dose reduction was organized at the company`s headquarters in 1986; in 1988, they proposed a five-year program to reduce by half the collective dose of 4 person-Sv per normal outage work. To achieve the target dose value, some dose-reduction measures were undertaken, namely, permanent radiation shielding, decontamination, automatic, operating machines, and ALARA organization. As the result, the collective dose from normal outage work was 1.6 person-Sv in 1992, which wasmore » less than the initial target value.« less

  17. ALARA and planning of interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocaboy, A.

    1995-03-01

    The implementation of ALARA programs implies integration of radiation protection criterion at all stages of outage management. Within the framework of its ALARA policy, Electricide de France (EDF) has given an incentive to all of its nuclear power plants to develop {open_quotes}good practices{close_quotes} in this domain, and to exchange their experience by the way of a national feed back file. Among the developments in the field of outage organization, some plants have focused on the planning stage of activities because of its influence on the radiological conditions of interventions and on the good succession of tasks within the radiological controlledmore » areas. This paper presents the experience of Chinon nuclear power plant. At Chinon, we are pursuing this goal through careful outage planning. We want the ALARA program during outages to be part of the overall maintenance task planning. This planning includes the provision of the availability of every safety-related component, and of the variations of water levels in hthereactor and steam generators to take advantage of the shield created by the water. We have developed a computerized data base with the exact position of all the components in the reactor building in order to avoid unnecessary interactions between different tasks performed in the same room. A common language between Operation and Maintenance had been established over the past years, using {open_quotes}Milestones and Corridors{close_quotes}. A real time dose rate counting system enables the Radiation Protection (RP) Department to do an accurate and efficient follow up during the outage for all the {open_quotes}ALARA{close_quotes} maintenance tasks.« less

  18. 77 FR 12096 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ... dealt with quickly and do not cause any client outages or connectivity issues. Due to the continuous... issues are dealt with quickly and do not cause any client outages or connectivity issues. Due to the... the Commission's Internet comment form ( http://www.sec.gov/rules/sro.shtml ); or Send an email to...

  19. Are Older Adults Prepared to Ensure Food Safety during Extended Power Outages and Other Emergencies?: Findings from a National Survey

    ERIC Educational Resources Information Center

    Kosa, Katherine M.; Cates, Sheryl C.; Karns, Shawn; Godwin, Sandria L.; Coppings, Richard J.

    2012-01-01

    Natural disasters and other emergencies can cause an increased risk of foodborne illness. We conducted a nationally representative survey to understand consumers' knowledge and use of recommended practices during/after extended power outages and other emergencies. Because older adults are at an increased risk for foodborne illness, this paper…

  20. Distortion outage minimization in Nakagami fading using limited feedback

    NASA Astrophysics Data System (ADS)

    Wang, Chih-Hong; Dey, Subhrakanti

    2011-12-01

    We focus on a decentralized estimation problem via a clustered wireless sensor network measuring a random Gaussian source where the clusterheads amplify and forward their received signals (from the intra-cluster sensors) over orthogonal independent stationary Nakagami fading channels to a remote fusion center that reconstructs an estimate of the original source. The objective of this paper is to design clusterhead transmit power allocation policies to minimize the distortion outage probability at the fusion center, subject to an expected sum transmit power constraint. In the case when full channel state information (CSI) is available at the clusterhead transmitters, the optimization problem can be shown to be convex and is solved exactly. When only rate-limited channel feedback is available, we design a number of computationally efficient sub-optimal power allocation algorithms to solve the associated non-convex optimization problem. We also derive an approximation for the diversity order of the distortion outage probability in the limit when the average transmission power goes to infinity. Numerical results illustrate that the sub-optimal power allocation algorithms perform very well and can close the outage probability gap between the constant power allocation (no CSI) and full CSI-based optimal power allocation with only 3-4 bits of channel feedback.

  1. Automatic scheduling of outages of nuclear power plants with time windows. Final report, January-December 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gomes, C.

    This report describes a successful project for transference of advanced AI technology into the domain of planning of outages of nuclear power plants as part of DOD`s dual-use program. ROMAN (Rome Lab Outage Manager) is the prototype system that was developed as a result of this project. ROMAN`s main innovation compared to the current state-of-the-art of outage management tools is its capability to automatically enforce safety constraints during the planning and scheduling phase. Another innovative aspect of ROMAN is the generation of more robust schedules that are feasible over time windows. In other words, ROMAN generates a family of schedulesmore » by assigning time intervals as start times to activities rather than single start times, without affecting the overall duration of the project. ROMAN uses a constraint satisfaction paradigm combining a global search tactic with constraint propagation. The derivation of very specialized representations for the constraints to perform efficient propagation is a key aspect for the generation of very fast schedules - constraints are compiled into the code, which is a novel aspect of our work using an automatic programming system, KIDS.« less

  2. Disparities in nuclear power plant performance in the United States and the Federal Republic of Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, K.F.; Winje, D.K.

    This report presents data comparing the performance of light water reactors in the United States and the Federal Republic of Germany (FRG). The comparisons are made for the years 1980 to 1983 and include 21 Westinghouse Pressurized Water Reactors (PWRs), 22 General Electric Boiling Water Reactors (BWRs) in the US; and 6 Kraftwerk Union (KWU) PWRs and 4 KWU BWRs in the FRG. Data on capacity losses are presented in a disaggregated form for scheduled outages, forced outages, and regulatory imposed outages. Further, within the scheduled and forced outages, the data are subdivided into losses associated with the nuclear island,more » the balance of plant, or other causes. The report also surveys a number of observations relating to the causes of discrepancies between the US and West Germany. These observations were obtained from interviews with executives and engineers in both nations, including people from vendors, utilities, regulators, and architect/engineers. These discussions are distilled into observations relating to national differences in the broad areas of economics and economic regulation, safety regulations, and technical and managerial differences. 9 refs., 2 figs., 26 tabs.« less

  3. Correlating Inferred Data Plane IPV6 Reboot Events With Control Plane BGP Activity

    DTIC Science & Technology

    2016-03-01

    22 Figure 3.6 Example Border Gateway Protocol (BGP) update message . . . . 23 Figure 3.7 Customer-provider relationship with border...government USN U.S. Navy VPN Virtual Private Network xiv Acknowledgments First, I would like to thank my family for their love , support, and...network outages when they restart . Network outages occur for many reasons: hardware failure, severe weather, misconfiguration, patching, upgrades

  4. Development of an Agent Based Model to Estimate and Reduce Time to Restoration of Storm Induced Power Outages

    NASA Astrophysics Data System (ADS)

    Walsh, T.; Layton, T.; Mellor, J. E.

    2017-12-01

    Storm damage to the electric grid impacts 23 million electric utility customers and costs US consumers $119 billion annually. Current restoration techniques rely on the past experiences of emergency managers. There are few analytical simulation and prediction tools available for utility managers to optimize storm recovery and decrease consumer cost, lost revenue and restoration time. We developed an agent based model (ABM) for storm recovery in Connecticut. An ABM is a computer modeling technique comprised of agents who are given certain behavioral rules and operate in a given environment. It allows the user to simulate complex systems by varying user-defined parameters to study emergent, unpredicted behavior. The ABM incorporates the road network and electric utility grid for the state, is validated using actual storm event recoveries and utilizes the Dijkstra routing algorithm to determine the best path for repair crews to travel between outages. The ABM has benefits for both researchers and utility managers. It can simulate complex system dynamics, rank variable importance, find tipping points that could significantly reduce restoration time or costs and test a broad range of scenarios. It is a modular, scalable and adaptable technique that can simulate scenarios in silico to inform emergency managers before and during storm events to optimize restoration strategies and better manage expectations of when power will be restored. Results indicate that total restoration time is strongly dependent on the number of crews. However, there is a threshold whereby more crews will not decrease the restoration time, which depends on the total number of outages. The addition of outside crews is more beneficial for storms with a higher number of outages. The time to restoration increases linearly with increasing repair time, while the travel speed has little overall effect on total restoration time. Crews traveling to the nearest outage reduces the total restoration time, while crews going to the outage with most customers affected increases the overall restoration time but more quickly decreases the customers remaining without power. This model can give utility company managers the ability to optimize their restoration strategies before or during a storm event to reduce restoration times and costs.

  5. SpalLoop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sabau, Adrian; Wright, Ian

    Boiler tubes in steam power plants experience tube blockages due to exfoliation of oxide grown on the inner side of the tubes. In extreme cases, significant tube blockages can lead to forced power plant outages. It is thus desired to predict through modeling the amount of tube blockage in order to inform power plant operators of possible forced outages. SpalLoop solves for the stress-strain equations in an axisymmetric geometry, tracking the stress/strain evolution during boiler operation including outages for the entire boiler tube length. At each operational outage, i.e., temperature excursions down to room temperature, the amount of exfoliated areamore » for the entire tube loop is estimated the amount of tube blockage is predicted based assumed blockage geometry and site. The SpaLLoop code contains modules developed for oxide growth, stress analysis, tube loop geometry, blockage area by taking into account the following phenomena and features, (a) Plant operation schedule with periodic alternate full-load and partial-load regimes and shut-downs, i.e., temperature excursions from high-load to room temperature, (b) axisymmetric formulation for cylindrical tubes, (c) oxide growth in a temperature gradient with multiple oxide layers, (d) geometry of a boiler tube with a single tube loop or two tube loops, (e) temperature variation along the tube length based on hot gas temperature distribution outside the tube and inlet steam temperature, (f) non-uniform oxide growth along the tube length according to the local steam tube temperature, (g) exfoliated area module: at each operational outage considered, the amount of exfoliated area and exfoliated volume along the tube is estimated, (h) blockage module: at each operational outage considered, the exfoliated volume/mass for each tube loop is estimated from which the amount of tube blockage is predicted based on given blockage geometry (length, location, and geometry). The computer program is written in FORTRAN90. Its modular structure was sought for allowing the best flexibility in updating the program by implementing new constitutive equations due to availability of new material property data and/or new physical phenomena.« less

  6. Bulk transmission system component outage data base. Research project 1283-1. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albrecht, P.F.; Heising, C.R.; Patton, A.D.

    1981-04-01

    This project is responsive to the premise that the successful analysis of equipment reliability and system adequacy in bulk transmission system planning and system operations requires data on equipment failure rates, maintenance outage rates and repair times. The objective of the project is to develop a system of consistent definitions, formats and procedures which can be used in the collection of such data in a well designed outage data bank. The project consisted of four interrelated phases, beginning with a review of related work and problem definition and ending with a discussion of data base organization and management. The reviewmore » of related work quickly pointed out that two schools of thought exist on data collection. One group contends that data should be collected on bulk transmission system physical equipments, such as transformers, circuit breakers, etc., and the other group supports data collection on functional transmission lines, including the terminal equipment, which have been defined as transmission units in this report. A compromise between these two approaches was imperative for successful completion of the work. The second phase investigated the data needed for reliability evaluation. The applications of the data bank were enumerated leading to a list of basic data needed when recording an incident. Phase 3 concentrated on developing procedures for data collection using forms to collect data both on outages and on the equipment design. Finally, the aspects of data base organization and management were explored and general recommendations made appropriate to this specific application. The project did not succeed in completely defining the procedures, particularly for multiple outages, but the ground work has been laid for a pilot data collection effort to refine the procedures before wide scale implementation by the utility industry.« less

  7. Method for estimating power outages and restoration during natural and man-made events

    DOEpatents

    Omitaomu, Olufemi A.; Fernandez, Steven J.

    2016-01-05

    A method of modeling electric supply and demand with a data processor in combination with a recordable medium, and for estimating spatial distribution of electric power outages and affected populations. A geographic area is divided into cells to form a matrix. Within the matrix, supply cells are identified as containing electric substations and demand cells are identified as including electricity customers. Demand cells of the matrix are associated with the supply cells as a function of the capacity of each of the supply cells and the proximity and/or electricity demand of each of the demand cells. The method includes estimating a power outage by applying disaster event prediction information to the matrix, and estimating power restoration using the supply and demand cell information of the matrix and standardized and historical restoration information.

  8. A RLS-SVM Aided Fusion Methodology for INS during GPS Outages

    PubMed Central

    Yao, Yiqing; Xu, Xiaosu

    2017-01-01

    In order to maintain a relatively high accuracy of navigation performance during global positioning system (GPS) outages, a novel robust least squares support vector machine (LS-SVM)-aided fusion methodology is explored to provide the pseudo-GPS position information for the inertial navigation system (INS). The relationship between the yaw, specific force, velocity, and the position increment is modeled. Rather than share the same weight in the traditional LS-SVM, the proposed algorithm allocates various weights for different data, which makes the system immune to the outliers. Field test data was collected to evaluate the proposed algorithm. The comparison results indicate that the proposed algorithm can effectively provide position corrections for standalone INS during the 300 s GPS outage, which outperforms the traditional LS-SVM method. Historical information is also involved to better represent the vehicle dynamics. PMID:28245549

  9. A RLS-SVM Aided Fusion Methodology for INS during GPS Outages.

    PubMed

    Yao, Yiqing; Xu, Xiaosu

    2017-02-24

    In order to maintain a relatively high accuracy of navigation performance during global positioning system (GPS) outages, a novel robust least squares support vector machine (LS-SVM)-aided fusion methodology is explored to provide the pseudo-GPS position information for the inertial navigation system (INS). The relationship between the yaw, specific force, velocity, and the position increment is modeled. Rather than share the same weight in the traditional LS-SVM, the proposed algorithm allocates various weights for different data, which makes the system immune to the outliers. Field test data was collected to evaluate the proposed algorithm. The comparison results indicate that the proposed algorithm can effectively provide position corrections for standalone INS during the 300 s GPS outage, which outperforms the traditional LS-SVM method. Historical information is also involved to better represent the vehicle dynamics.

  10. Turbine lubricating oil: New filtration advances save time and money

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bushar, T.

    1996-11-01

    This article describes benefits of filtration advances which include fewer forced outages, faster startups and reduced bearing wear. The importance of clean lubricating oil for turbines has been recognized for a long time, and almost all generating plants use some type of filtration system. Many older technologies and systems cannot remove enough of the contaminants to meet the needs of today`s turbines and operating conditions. Newer filtration technologies, such as multiphase filtration systems incorporating pressure coalescence filters to remove water, can reduce contaminants to levels that will help prevent unscheduled or forced outages, allow faster startups after an ongoing outage,more » and reduce wear of bearings and other components. Such preventive measures are more important than ever because of today`s increased competition and emphasis on cost control.« less

  11. Restoring Faith in the bulk-power system: an early assessment of mandatory reliability standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McAllister, Levi; Dawson, Kelly L.

    2010-03-15

    The driving force underlying creation of mandatory reliability standards was the prevention of widespread outages, such as those that occurred in 1965, 1977 and 2003. So far, no similar outage has occurred when an entity is in full compliance with the standards, and NERC and FERC have demonstrated that they will actively enforce compliance while aggressively pursuing entities alleged to be non-compliant. (author)

  12. Worldwide OMEGA and Very Low Frequency (VLF) Transmitter Outages, January to December 1980.

    DTIC Science & Technology

    1981-05-01

    WORLDWIDE OMEGA AND VERY LOW FREQUENCY IVLF) TRANSMITTER OUTAGE--ETC, MAY 81 L RZONCA ,’,L.ASSI LED FAA-CT-81-26 FAA-RD- B1 -29 UL7 A-I’ l15FDRL AIO...computer for the time period GBR - Rugby , England (16.00 kHz) January to December 1980. (For the purposes of this report, any downtime NA - Cutler, Maine

  13. Diarrheal Illness Detected Through Syndromic Surveillance After a Massive Power Outage: New York City, August 2003

    PubMed Central

    Marx, Melissa A.; Rodriguez, Carla V.; Greenko, Jane; Das, Debjani; Heffernan, Richard; Karpati, Adam M.; Mostashari, Farzad; Balter, Sharon; Layton, Marcelle; Weiss, Don

    2006-01-01

    Objectives. We investigated increases in diarrheal illness detected through syndromic surveillance after a power outage in New York City on August 14, 2003. Methods. The New York City Department of Health and Mental Hygiene uses emergency department, pharmacy, and absentee data to conduct syndromic surveillance for diarrhea. We conducted a case–control investigation among patients presenting during August 16 to 18, 2003, to emergency departments that participated in syndromic surveillance. We compared risk factors for diarrheal illness ascertained through structured telephone interviews for case patients presenting with diarrheal symptoms and control patients selected from a stratified random sample of nondiarrheal patients. Results. Increases in diarrhea were detected in all data streams. Of 758 patients selected for the investigation, 301 (40%) received the full interview. Among patients 13 years and older, consumption of meat (odds ratio [OR]=2.7, 95% confidence interval [CI]=1.2, 6.1) and seafood (OR=4.8; 95% CI=1.6, 14) between the power outage and symptom onset was associated with diarrheal illness. Conclusions. Diarrhea may have resulted from consumption of meat or seafood that spoiled after the power outage. Syndromic surveillance enabled prompt detection and systematic investigation of citywide illness that would otherwise have gone undetected. PMID:16380562

  14. Deep Space Optical Link ARQ Performance Analysis

    NASA Technical Reports Server (NTRS)

    Clare, Loren; Miles, Gregory

    2016-01-01

    Substantial advancements have been made toward the use of optical communications for deep space exploration missions, promising a much higher volume of data to be communicated in comparison with present -day Radio Frequency (RF) based systems. One or more ground-based optical terminals are assumed to communicate with the spacecraft. Both short-term and long-term link outages will arise due to weather at the ground station(s), space platform pointing stability, and other effects. To mitigate these outages, an Automatic Repeat Query (ARQ) retransmission method is assumed, together with a reliable back channel for acknowledgement traffic. Specifically, the Licklider Transmission Protocol (LTP) is used, which is a component of the Disruption-Tolerant Networking (DTN) protocol suite that is well suited for high bandwidth-delay product links subject to disruptions. We provide an analysis of envisioned deep space mission scenarios and quantify buffering, latency and throughput performance, using a simulation in which long-term weather effects are modeled with a Gilbert -Elliot Markov chain, short-term outages occur as a Bernoulli process, and scheduled outages arising from geometric visibility or operational constraints are represented. We find that both short- and long-term effects impact throughput, but long-term weather effects dominate buffer sizing and overflow losses as well as latency performance.

  15. Sampled-data-based vibration control for structural systems with finite-time state constraint and sensor outage.

    PubMed

    Weng, Falu; Liu, Mingxin; Mao, Weijie; Ding, Yuanchun; Liu, Feifei

    2018-05-10

    The problem of sampled-data-based vibration control for structural systems with finite-time state constraint and sensor outage is investigated in this paper. The objective of designing controllers is to guarantee the stability and anti-disturbance performance of the closed-loop systems while some sensor outages happen. Firstly, based on matrix transformation, the state-space model of structural systems with sensor outages and uncertainties appearing in the mass, damping and stiffness matrices is established. Secondly, by considering most of those earthquakes or strong winds happen in a very short time, and it is often the peak values make the structures damaged, the finite-time stability analysis method is introduced to constrain the state responses in a given time interval, and the H-infinity stability is adopted in the controller design to make sure that the closed-loop system has a prescribed level of disturbance attenuation performance during the whole control process. Furthermore, all stabilization conditions are expressed in the forms of linear matrix inequalities (LMIs), whose feasibility can be easily checked by using the LMI Toolbox. Finally, numerical examples are given to demonstrate the effectiveness of the proposed theorems. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Reliability analysis of a utility-scale solar power plant

    NASA Astrophysics Data System (ADS)

    Kolb, G. J.

    1992-10-01

    This paper presents the results of a reliability analysis for a solar central receiver power plant that employs a salt-in-tube receiver. Because reliability data for a number of critical plant components have only recently been collected, this is the first time a credible analysis can be performed. This type of power plant will be built by a consortium of western US utilities led by the Southern California Edison Company. The 10 MW plant is known as Solar Two and is scheduled to be on-line in 1994. It is a prototype which should lead to the construction of 100 MW commercial-scale plants by the year 2000. The availability calculation was performed with the UNIRAM computer code. The analysis predicted a forced outage rate of 5.4 percent and an overall plant availability, including scheduled outages, of 91 percent. The code also identified the most important contributors to plant unavailability. Control system failures were identified as the most important cause of forced outages. Receiver problems were rated second with turbine outages third. The overall plant availability of 91 percent exceeds the goal identified by the US utility study. This paper discuses the availability calculation and presents evidence why the 91 percent availability is a credible estimate.

  17. Outage analysis of relay-assisted underwater wireless optical communication systems

    NASA Astrophysics Data System (ADS)

    Tabeshnezhad, Azadeh; Pourmina, Mohammad Ali

    2017-12-01

    In this paper, we theoretically evaluate the outage probabilities of underwater wireless optical communication (UWOC) systems. Our derivations are general as the channel model under consideration takes into account all of the channel degrading effects, namely absorption, scattering, and turbulence-induced fading. We numerically show that the UWOC systems, due to the severe channel impairments, cannot typically support longer link ranges than 100 m. Therefore, in this paper, in order to increase the transmission reliability and hence extend the viable communication range of UWOC systems, we apply decode-and-forward (DF) relay-assisted communications either in the form of multi-hop transmission, where multiple intermediate relays are serially employed between the source and destination, or parallel relaying in which multiple DF relays are distributed among the source-to-destination path to cooperate in the end-to-end transmission. Our numerical results reveal that multi-hop transmission, owing to the distance-dependency of all of the channel degrading effects, can tremendously improve the end-to-end outage probability and increase the accessible link ranges to hundreds of meter. For example, a dual-hop transmission in a 45 m coastal water link can provide up to 41 dB performance improvement at the outage probability of 10-9.

  18. A High Resolution Tropical Cyclone Power Outage Forecasting Model for the Continental United States

    NASA Astrophysics Data System (ADS)

    Pino, J. V.; Quiring, S. M.; Guikema, S.; Shashaani, S.; Linger, S.; Backhaus, S.

    2017-12-01

    Tropical cyclones cause extensive damage to the power infrastructure system throughout the United States. This damage can leave millions without power for extended periods of time, as most recently seen with Hurricane Matthew (2016). Accurate and timely prediction of power outages are essential for utility companies, emergency management agencies, and governmental organizations. Here we present a high-resolution (250 m x 250 m) hurricane power outage model for the United States. The model uses only publicly-available data to make predictions. It uses forecasts of storm variables such as maximum 3-second wind gust, duration of strong winds > 20 m s-2, soil moisture, and precipitation. It also incorporates static environmental variables such as elevation characteristics, land cover type, population density, tree species data, and root zone depth. A web tool was established for use by the Department of Energy (DOE) so that the model can be used for real-time outage forecasting or for synthetic tropical cyclones as an exercise in emergency management. This web tool provides DOE decision-makers with high impact analytic results and products that can be disseminated to federal, local, and state agencies. The results then aid utility companies in their pre- and post-storm activities, thus decreasing restoration times and lowering costs.

  19. Average BER and outage probability of the ground-to-train OWC link in turbulence with rain

    NASA Astrophysics Data System (ADS)

    Zhang, Yixin; Yang, Yanqiu; Hu, Beibei; Yu, Lin; Hu, Zheng-Da

    2017-09-01

    The bit-error rate (BER) and outage probability of optical wireless communication (OWC) link for the ground-to-train of the curved track in turbulence with rain is evaluated. Considering the re-modulation effects of raining fluctuation on optical signal modulated by turbulence, we set up the models of average BER and outage probability in the present of pointing errors, based on the double inverse Gaussian (IG) statistical distribution model. The numerical results indicate that, for the same covered track length, the larger curvature radius increases the outage probability and average BER. The performance of the OWC link in turbulence with rain is limited mainly by the rain rate and pointing errors which are induced by the beam wander and train vibration. The effect of the rain rate on the performance of the link is more severe than the atmospheric turbulence, but the fluctuation owing to the atmospheric turbulence affects the laser beam propagation more greatly than the skewness of the rain distribution. Besides, the turbulence-induced beam wander has a more significant impact on the system in heavier rain. We can choose the size of transmitting and receiving apertures and improve the shockproof performance of the tracks to optimize the communication performance of the system.

  20. Emergency preparedness for power outages and wi-fi loss: tips for students and educators of online courses.

    PubMed

    Heithaus, Teresa

    2015-01-01

    Severe weather can impact online education due to a loss of power and Internet access that can last hours or weeks. Planning for such losses is essential to enable participation in the online classroom. This article discusses measures that can be used to maintain an online presence in the event of a power outage or loss of Wi-Fi. Copyright 2015, SLACK Incorporated.

  1. Splice loss requirements in multi-mode fiber mode-division-multiplex transmission links.

    PubMed

    Warm, Stefan; Petermann, Klaus

    2013-01-14

    We investigate numerically the influence of fiber splices and fiber connectors to the statistics of mode dependent loss (MDL) and multiple-input multiple-output (MIMO) outage capacity in mode multiplexed multi-mode fiber links. Our results indicate required splice losses much lower than currently feasible to achieve a reasonable outage capacity in long-haul transmission systems. Splice losses as low as 0.03dB may effectively lead to an outage of MIMO channels after only a few hundred kilometers transmission length. In a first approximation, the relative capacity solely depends on the accumulated splice loss and should be less than ≈ 2dB to ensure a relative capacity of 90%. We also show that discrete mode permutation (mixing) within the transmission line may effectively increase the maximum transmission distance by a factor of 5 for conventional splice losses.

  2. Recent Performance of and Plasma Outage Studies with the SNS H- Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stockli, Martin P; Han, Baoxi; Murray Jr, S N

    2016-01-01

    SNS ramps to higher power levels that can be sustained with high availability. The goal is 1.4 MW despite a compromised RFQ, which requires higher RF power than design levels to approach the nominal beam transmission. Unfortunately at higher power the RFQ often loses its thermal stability, a problem apparently enhanced by beam losses and high influxes of hydrogen. Delivering as much H- beam as possible with the least amount of hydrogen led to plasma outages. The root cause is the dense 1-ms long ~55-kW 2-MHz plasma pulses reflecting ~90% of the continuous ~300W, 13-MHz power, which was mitigated withmore » a 4-ms filter for the reflected power signal and an outage resistant, slightly-detuned 13-MHz match. Lowering the H2 also increased the H- beam current to ~55 mA, and increased the transmission by ~7%.« less

  3. Moisture separator reheater upgrade at Surry nuclear power station

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bankley, A.

    1985-01-01

    Surry station moisture separator reheaters (MSRs) have experienced numerous problems typical of those found in MSRs of large nuclear power plants. The reliability of MSRs has been of concern to users for several years, primarily in regard to their structural integrity, operational characteristics and performance. Gross MSR internal problems such as reheater tube failures, inadequate moisture separation, buckling, and distortion of internal components occasionally necessitate forced outages or nonscheduled repairs or removal of a particular MSR from operation until repairs can be performed during a scheduled outage. It was obvious that the financial consequences of forced outages or reduced performancemore » were grave and their elimination was an important betterment goal. The objective of this paper is to present past failures of MSRs and modifications that were made to the vessel internals, and to compare their performance prior to and after the improved design was implemented.« less

  4. A cascading failure analysis tool for post processing TRANSCARE simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This is a MATLAB-based tool to post process simulation results in the EPRI software TRANSCARE, for massive cascading failure analysis following severe disturbances. There are a few key modules available in this tool, including: 1. automatically creating a contingency list to run TRANSCARE simulations, including substation outages above a certain kV threshold, N-k (1, 2 or 3) generator outages and branche outages; 2. read in and analyze a CKO file of PCG definition, an initiating event list, and a CDN file; 3. post process all the simulation results saved in a CDN file and perform critical event corridor analysis; 4.more » provide a summary of TRANSCARE simulations; 5. Identify the most frequently occurring event corridors in the system; and 6. Rank the contingencies using a user defined security index to quantify consequences in terms of total load loss, total number of cascades, etc.« less

  5. Capacity Improvement of a Free Space Optical Satellite Uplink using Transmitter Power and Rate Adaptation

    NASA Astrophysics Data System (ADS)

    Gopal, Pooja; Jain, V. K.; Kar, Subrat

    2017-12-01

    Degradation due to atmospheric turbulence leads to significant outage in a free space optical satellite uplink with fixed transmitter parameters. If the channel state is known at the transmitter, then its parameters can be suitably changed, and there could be a considerable improvement in channel capacity. However, the extremely long link length of an Earth-to-Geostationary Earth Orbit (GEO) satellite link would render feedback of channel state from the receiver infeasible, before the channel changes. In this paper, a channel pre-estimation method at the transmitter is proposed, and the expression for capacity with transmitter power and rate adaptation is derived. The results are compared with that of the capacity with outage. It is observed that there can be an improvement by a factor of 1.66 in achievable average capacity per Hertz with the adaptive transmitter. Also, the outage probability is reduced from 18.02 % to almost 0.

  6. Outage management and health physics issue, 2009

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    2009-05-15

    The focus of the May-June issue is on outage management and health physics. Major articles include the following: Planning and scheduling to minimize refueling outage, by Pat McKenna, AmerenUE; Prioritizing safety, quality and schedule, by Tom Sharkey, Dominion; Benchmarking to high standards, by Margie Jepson, Energy Nuclear; Benchmarking against U.S. standards, by Magnox North, United Kingdom; Enabling suppliers for new build activity, by Marcus Harrington, GE Hitachi Nuclear Energy; Identifying, cultivating and qualifying suppliers, by Thomas E. Silva, AREVA NP; Creating new U.S. jobs, by Francois Martineau, Areva NP. Industry innovation articles include: MSL Acoustic source load reduction, by Amirmore » Shahkarami, Exelon Nuclear; Dual Methodology NDE of CRDM nozzles, by Michael Stark, Dominion Nuclear; and Electronic circuit board testing, by James Amundsen, FirstEnergy Nuclear Operating Company. The plant profile article is titled The future is now, by Julia Milstead, Progress Energy Service Company, LLC.« less

  7. Interleaved Training and Training-Based Transmission Design for Hybrid Massive Antenna Downlink

    NASA Astrophysics Data System (ADS)

    Zhang, Cheng; Jing, Yindi; Huang, Yongming; Yang, Luxi

    2018-06-01

    In this paper, we study the beam-based training design jointly with the transmission design for hybrid massive antenna single-user (SU) and multiple-user (MU) systems where outage probability is adopted as the performance measure. For SU systems, we propose an interleaved training design to concatenate the feedback and training procedures, thus making the training length adaptive to the channel realization. Exact analytical expressions are derived for the average training length and the outage probability of the proposed interleaved training. For MU systems, we propose a joint design for the beam-based interleaved training, beam assignment, and MU data transmissions. Two solutions for the beam assignment are provided with different complexity-performance tradeoff. Analytical results and simulations show that for both SU and MU systems, the proposed joint training and transmission designs achieve the same outage performance as the traditional full-training scheme but with significant saving in the training overhead.

  8. Monitoring Disaster-Related Power Outages Using NASA Black Marble Nighttime Light Product

    NASA Astrophysics Data System (ADS)

    Wang, Z.; Román, M. O.; Sun, Q.; Molthan, A. L.; Schultz, L. A.; Kalb, V. L.

    2018-04-01

    Timely and accurate monitoring of disruptions to the electricity grid, including the magnitude, spatial extent, timing, and duration of net power losses, is needed to improve situational awareness of disaster response and long-term recovery efforts. Satellite-derived Nighttime Lights (NTL) provide an indication of human activity patterns and have been successfully used to monitor disaster-related power outages. The global 500 m spatial resolution National Aeronautics and Space Administration (NASA) Black Marble NTL daily standard product suite (VNP46) is generated from Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) onboard the NASA/National Oceanic and Atmospheric Administration (NOAA) Suomi National Polar-orbiting Partnership (Suomi- NPP) satellite, which began operations on 19 January 2012. With its improvements in product accuracy (including critical atmospheric and BRDF correction routines), the VIIRS daily Black Mable product enables systematic monitoring of outage conditions across all stages of the disaster management cycle.

  9. Estimates of outage costs of electricity in Pakistan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashraf, J.; Sabih, F.

    1993-12-31

    This article estimates outage costs of electricity for each of the four provinces in Pakistan (Punjab, North-West Frontier Province, Baluchistan, and Sind). The term {open_quotes}power outage{close_quotes} refers to all problems associated with electricity supply, such as voltage drops (brownouts), power failures (blackouts), and load shedding. The most significant of these in Pakistan is load shedding when power supply to different consumers is shut off during different times of the day, especially during peak hours when the pressure on the system is the highest. Power shortages mainly arise during the low-water months when the effective capacity of hydropower plants drops significantly.more » This decline in power supplied by hydro plants cannot be made up by operating thermal power plants because of the limited availability of gas and the high cost of alternative fuels required for the operation of gas turbines.« less

  10. Outage probability of a relay strategy allowing intra-link errors utilizing Slepian-Wolf theorem

    NASA Astrophysics Data System (ADS)

    Cheng, Meng; Anwar, Khoirul; Matsumoto, Tad

    2013-12-01

    In conventional decode-and-forward (DF) one-way relay systems, a data block received at the relay node is discarded, if the information part is found to have errors after decoding. Such errors are referred to as intra-link errors in this article. However, in a setup where the relay forwards data blocks despite possible intra-link errors, the two data blocks, one from the source node and the other from the relay node, are highly correlated because they were transmitted from the same source. In this article, we focus on the outage probability analysis of such a relay transmission system, where source-destination and relay-destination links, Link 1 and Link 2, respectively, are assumed to suffer from the correlated fading variation due to block Rayleigh fading. The intra-link is assumed to be represented by a simple bit-flipping model, where some of the information bits recovered at the relay node are the flipped version of their corresponding original information bits at the source. The correlated bit streams are encoded separately by the source and relay nodes, and transmitted block-by-block to a common destination using different time slots, where the information sequence transmitted over Link 2 may be a noise-corrupted interleaved version of the original sequence. The joint decoding takes place at the destination by exploiting the correlation knowledge of the intra-link (source-relay link). It is shown that the outage probability of the proposed transmission technique can be expressed by a set of double integrals over the admissible rate range, given by the Slepian-Wolf theorem, with respect to the probability density function ( pdf) of the instantaneous signal-to-noise power ratios (SNR) of Link 1 and Link 2. It is found that, with the Slepian-Wolf relay technique, so far as the correlation ρ of the complex fading variation is | ρ|<1, the 2nd order diversity can be achieved only if the two bit streams are fully correlated. This indicates that the diversity order exhibited in the outage curve converges to 1 when the bit streams are not fully correlated. Moreover, the Slepian-Wolf outage probability is proved to be smaller than that of the 2nd order maximum ratio combining (MRC) diversity, if the average SNRs of the two independent links are the same. Exact as well as asymptotic expressions of the outage probability are theoretically derived in the article. In addition, the theoretical outage results are compared with the frame-error-rate (FER) curves, obtained by a series of simulations for the Slepian-Wolf relay system based on bit-interleaved coded modulation with iterative detection (BICM-ID). It is shown that the FER curves exhibit the same tendency as the theoretical results.

  11. AUTOMATED UTILITY SERVICE AREA ASSESSMENT UNDER EMERGENCY CONDITIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G. TOOLE; S. LINGER

    2001-01-01

    All electric utilities serve power to their customers through a variety of functional levels, notably substations. The majority of these components consist of distribution substations operating at lower voltages while a small fraction are transmission substations. There is an associated geographical area that encompasses customers who are served, defined as the service area. Analysis of substation service areas is greatly complicated by several factors: distribution networks are often highly interconnected which allows a multitude of possible switching operations; also, utilities dynamically alter the network topology in order to respond to emergency events. As a result, the service area for amore » substation can change radically. A utility will generally attempt to minimize the number of customers outaged by switching effected loads to alternate substations. In this manner, all or a portion of a disabled substation's load may be served by one or more adjacent substations. This paper describes a suite of analytical tools developed at Los Alamos National Laboratory (LANL), which address the problem of determining how a utility might respond to such emergency events. The estimated outage areas derived using the tools are overlaid onto other geographical and electrical layers in a geographic information system (GIS) software application. The effects of a power outage on a population, other infrastructures, or other physical features, can be inferred by the proximity of these features to the estimated outage area.« less

  12. Use of VIIRS DNB Data to Monitor Power Outages and Restoration for Significant Weather Events

    NASA Technical Reports Server (NTRS)

    Jedlovec, Gary; Molthan, Andrew

    2008-01-01

    NASA fs Short-term Prediction Research and Transition (SPoRT) project operates from NASA's Marshall Space Flight Center in Huntsville, Alabama. The team provides unique satellite data to the National Weather Service (NWS) and other agencies and organizations for weather analysis. While much of its work is focused on improving short-term weather forecasting, the SPoRT team supported damage assessment and response to Hurricane Superstorm Sandy by providing imagery that highlighted regions without power. The team used data from the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (Suomi NPP) satellite. The VIIRS low-light sensor, known as the day-night-band (DNB), can detect nighttime light from wildfires, urban and rural communities, and other human activity which emits light. It can also detect moonlight reflected from clouds and surface features. Using real time VIIRS data collected by our collaborative partner at the Space Science and Engineering Center of the University of Wisconsin, the SPoRT team created composite imagery to help detect power outages and restoration. This blackout imagery allowed emergency response teams from a variety of agencies to better plan and marshal resources for recovery efforts. The blackout product identified large-scale outages, offering a comprehensive perspective beyond a patchwork GIS mapping of outages that utility companies provide based on customer complaints. To support the relief efforts, the team provided its imagery to the USGS data portal, which the Federal Emergency Management Agency (FEMA) and other agencies used in their relief efforts. The team fs product helped FEMA, the U.S. Army Corps of Engineers, and U.S. Army monitor regions without power as part of their disaster response activities. Disaster responders used the images to identify possible outages and effectively distribute relief resources. An enhanced product is being developed and integrated into a web mapping service (WMS) for dissemination and use by a broader end user community.

  13. Decontamination, decommissioning, and vendor advertorial issue, 2006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    2006-07-15

    The focus of the July-August issue is on Decontamination, decommissioning, and vendor advertorials. Major articles/reports in this issue include: NPP Krsko revised decommissioning program, by Vladimir Lokner and Ivica Levanat, APO d.o.o., Croatia, and Nadja Zeleznik and Irena Mele, ARAO, Slovenia; Supporting the renaissance, by Marilyn C. Kray, Exelon Nuclear; Outage world an engineer's delight, by Tom Chrisopher, Areva, NP Inc.; Optimizing refueling outages with R and D, by Ross Marcoot, GE Energy; and, A successful project, by Jim Lash, FirstEnergy.

  14. An Internet of Things Approach to Electrical Power Monitoring and Outage Reporting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koch, Daniel B

    The so-called Internet of Things concept has captured much attention recently as ordinary devices are connected to the Internet for monitoring and control purposes. One enabling technology is the proliferation of low-cost, single board computers with built-in network interfaces. Some of these are capable of hosting full-fledged operating systems that provide rich programming environments. Taken together, these features enable inexpensive solutions for even traditional tasks such as the one presented here for electrical power monitoring and outage reporting.

  15. Towards Availability and Maintainability Benchmarks: A Case Study of Software RAID Systems

    DTIC Science & Technology

    2001-01-01

    on recent outages of big e-commerce providers and the major business impact of those out- ages is staggering; furthermore, several of those outages...uses one or more clients to generate a realistic, statistically reproducible web workload; its workload models what might be seen on a busy major server...the amount of dynamic content from 30% to 1% to keep the disks busy and to avoid saturating the CPU. This restriction was necessary because we used

  16. Design Concepts for an Outage Control Center Information Dashboard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hugo, Jacques Victor; St Germain, Shawn Walter; Thompson, Cheradan Jo

    The nuclear industry, and the business world in general, is facing a rapidly increasing amount of data to be dealt with on a daily basis. In the last two decades, the steady improvement of data storage devices and means to create and collect data along the way influenced the manner in which we deal with information. Most data is still stored without filtering and refinement for later use. Many functions at a nuclear power plant generate vast amounts of data, with scheduled and unscheduled outages being a prime example of a source of some of the most complex data setsmore » at the plant. To make matters worse, modern information and communications technology is making it possible to collect and store data faster than our ability to use it for making decisions. However, in most applications, especially outages, raw data has no value in itself; instead, managers, engineers and other specialists want to extract the information contained in it. The complexity and sheer volume of data could lead to information overload, resulting in getting lost in data that may be irrelevant to the task at hand, processed in an inappropriate way, or presented in an ineffective way. To prevent information overload, many data sources are ignored so production opportunities are lost because utilities lack the ability to deal with the enormous data volumes properly. Decision-makers are often confronted with large amounts of disparate, conflicting and dynamic information, which are available from multiple heterogeneous sources. Information and communication technologies alone will not solve this problem. Utilities need effective methods to exploit and use the hidden opportunities and knowledge residing in unexplored data resources. Superior performance before, during and after outages depends upon the right information being available at the right time to the right people. Acquisition of raw data is the easy part; instead, it is the ability to use advanced analytical, data processing and data visualization methods to turn the data into reliable information and comprehensible, actionable information. Techniques like data mining, filtering and analysis only work reliably for well-defined and well-understood problems. The path from data to decision is more complex. The ability to communicate knowledge during outages and emergent issues is crucial. This paper presents an approach to turn the unused data into an opportunity: applying principles from semiotics, human factors and visual analytics to transform the traditional way of processing outage data into media that will improve the collective situation awareness, knowledge, decisions, actions and overall performance of the entire outage team, and also support the reliability, quality and overall effectiveness of maintenance work. The application of the proposed visualization methods will become the medium of a semi-automated analytical process where humans and machines cooperate using their respective, distinct capabilities for the most effective results.« less

  17. Recent performance of and plasma outage studies with the SNS H{sup −} source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stockli, M. P., E-mail: stockli@ornl.gov; Han, B.; Murray, S. N.

    2016-02-15

    Spallation Neutron Source ramps to higher power levels that can be sustained with high availability. The goal is 1.4 MW despite a compromised radio frequency quadrupole (RFQ), which requires higher radio frequency power than design levels to approach the nominal beam transmission. Unfortunately at higher power the RFQ often loses its thermal stability, a problem apparently enhanced by beam losses and high influxes of hydrogen. Delivering as much H{sup −} beam as possible with the least amount of hydrogen led to plasma outages. The root cause is the dense 1-ms long ∼55-kW 2-MHz plasma pulses reflecting ∼90% of the continuousmore » ∼300 W, 13-MHz power, which was mitigated with a 4-ms filter for the reflected power signal and an outage resistant, slightly detuned 13-MHz match. Lowering the H{sub 2} gas also increased the H{sup −} beam current to ∼55 mA and increased the RFQ transmission by ∼7% (relative)« less

  18. Using Rapid Improvement Events for Disaster After-Action Reviews: Experience in a Hospital Information Technology Outage and Response.

    PubMed

    Little, Charles M; McStay, Christopher; Oeth, Justin; Koehler, April; Bookman, Kelly

    2018-02-01

    The use of after-action reviews (AARs) following major emergency events, such as a disaster, is common and mandated for hospitals and similar organizations. There is a recurrent challenge of identified problems not being resolved and repeated in subsequent events. A process improvement technique called a rapid improvement event (RIE) was used to conduct an AAR following a complete information technology (IT) outage at a large urban hospital. Using RIE methodology to conduct the AAR allowed for the rapid development and implementation of major process improvements to prepare for future IT downtime events. Thus, process improvement methodology, particularly the RIE, is suited for conducting AARs following disasters and holds promise for improving outcomes in emergency management. Little CM , McStay C , Oeth J , Koehler A , Bookman K . Using rapid improvement events for disaster after-action reviews: experience in a hospital information technology outage and response. Prehosp Disaster Med. 2018;33(1):98-100.

  19. Hospital emergency department visits for carbon monoxide poisoning following an October 2006 snowstorm in western New York.

    PubMed

    Muscatiello, Neil A; Babcock, Gwen; Jones, Rena; Horn, Edward; Hwang, Syni-An

    2010-01-01

    Following an October 2006 snowstorm that caused widespread power outages in western New York State, hospital emergency department (ED) visits for carbon monoxide (CO) poisoning increased. Overall, 264 people representing 155 households were diagnosed with CO poisoning during the power outages. Telephone interviews were conducted with a subset of these individuals. Respondents provided information about exposure sources, CO alarms, and awareness of CO warnings. In many households, portable generators were operated in an enclosed area. Awareness of CO warnings may have contributed to knowledge about locating portable generators outside. When operated outside, however, portable generators were generally located too close to the home. Gas kitchen ranges were used for heat by numerous households. In the short term, CO education and improved clarity of CO warning information is important for increasing awareness about power outage-related CO risks. Improvements in the combustion efficiency of portable generators should be a long-term goal.

  20. Assessment and Application of the ROSE Code for Reactor Outage Thermal-Hydraulic and Safety Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, Thomas K.S.; Ko, F.-K.; Dai, L.-C

    The currently available tools, such as RELAP5, RETRAN, and others, cannot easily and correctly perform the task of analyzing the system behavior during plant outages. Therefore, a medium-sized program aiming at reactor outage simulation and evaluation, such as midloop operation (MLO) with loss of residual heat removal (RHR), has been developed. Important thermal-hydraulic processes involved during MLO with loss of RHR can be properly simulated by the newly developed reactor outage simulation and evaluation (ROSE) code. The two-region approach with a modified two-fluid model has been adopted to be the theoretical basis of the ROSE code.To verify the analytical modelmore » in the first step, posttest calculations against the integral midloop experiments with loss of RHR have been performed. The excellent simulation capacity of the ROSE code against the Institute of Nuclear Energy Research Integral System Test Facility test data is demonstrated. To further mature the ROSE code in simulating a full-sized pressurized water reactor, assessment against the WGOTHIC code and the Maanshan momentary-loss-of-RHR event has been undertaken. The successfully assessed ROSE code is then applied to evaluate the abnormal operation procedure (AOP) with loss of RHR during MLO (AOP 537.4) for the Maanshan plant. The ROSE code also has been successfully transplanted into the Maanshan training simulator to support operator training. How the simulator was upgraded by the ROSE code for MLO will be presented in the future.« less

  1. Dependable Networks as a Paradigm for Network Innovation

    NASA Astrophysics Data System (ADS)

    Miki, Tetsuya

    In past, dependable networks meant minimizing network outages or the impact of the outages. However, over the decade, major network services have shifted from telephone and data transmission to Internet and to mobile communication, where higher layer services with a variety of contents are provided. Reviewing these backgrounds of network development, the importance of the dependability of higher layer network services are pointed out. Then, the main aspects to realize the dependability are given for lower, middle and higher layer network services. In addition, some particular issues for dependable networks are described.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    The focus of the May-June issue is on outage management and health physics. Major articles include: Outage optimization initiatives, by George B. Beam, AREVA NP, Inc.; New plant based on excellent track records, by Jim Scarola, Progress Energy; Meeting customer needs and providing environmental benefits, by Peter S. Hastings, Duke Energy; Plants with 3-D design, by Jack A. Bailey, Tennessee Valley Authority; and Highest quality with exceptional planning, by Jason A. Walls, Duke Energy. Industry innovation articles include: Integrated exposure reduction plan, by Ed Wolfe, Exelon; Performance-based radiation worker training, by Joe Giuffre and Timothy Vriezerma, American Electric Power.

  3. Global investigations of the satellite-based Fugro OmniSTAR HP service

    NASA Astrophysics Data System (ADS)

    Pflugmacher, Andreas; Heister, Hansbert; Heunecke, Otto

    2009-12-01

    OmniSTAR is one of the world's leading suppliers of satellite-based augmentation services for onshore and offshore GNSS applications. OmniSTAR currently offers three services: VBS, HP and XP. OmniSTAR VBS is the code-based service, suitable for sub-metre positioning accuracy. The HP and XP services provide sub-decimetre accuracy, with the HP service based on a precise differential methodology and the XP service uses precise absolute positioning. The sub-decimetre HP and XP services both have distinctive convergence behaviour, and the positioning task is essentially a time-dependent process during which the accuracy of the estimated coordinates continuously improves over time. To validate the capabilities of the OmniSTAR services, and in particular the HP (High Performance) service, globally distributed measurement campaigns were performed. The results of these investigations confirm that the HP service satisfies its high accuracy specification, but only after a sufficient initialisation phase. Two kinds of disturbances can handicap HP operation: lack of GNSS observations and outages of the augmentation signal. The most serious kind of disturbance is the former. Within a few seconds the achieved convergence level is completely lost. Outages in the reception of augmentation data merely affect the relevant period of the outage - the accuracy during the outage is degraded. Only longer interruptions lead to a loss of the HP solution. When HP convergence is lost, the HP process has to be re-initialized. If there are known points (so-called “seed points”) available, a shortened “kick-start”-initialization is possible. With the aid of seed points it only takes a few minutes to restore convergence.

  4. Trusted information sources used during and after Superstorm Sandy: TV and radio were used more often than social media

    PubMed Central

    Burger, Joanna; Gochfeld, Michael; Jeitner, Christian; Pittfield, Taryn; Donio, Mark

    2015-01-01

    Health and safety professionals, and the public, are interested in the best methods of providing timely information about disasters. The objective of this study was to examine information sources used for Superstorm Sandy with respect to the storm, evacuation routes, shelters, safety, and health issues. Respondents in Central New Jersey and Jersey Shore communities were differentially impacted by the storm. Jersey shore respondents had higher evacuation rates (47 % vs 13 %), higher flood waters in homes, longer power outages (average 23 vs 6 days), and longer periods without internet (29 vs 6 days). Electricity outages disrupted both sources and receivers of communication. Both groups obtained most of their information regarding safety from television, radio, friends and web/email. Information sources on health varied by location, with central Jersey respondents using mainly TV and the web, and Jersey shore respondents obtaining health information from the radio, and TV (before the storm). For information on evacuation routes, Jersey shore respondents obtained information from many sources, while central Jersey respondents obtained it from TV. Information on mold was largely obtained from friends and the web, since mold issues were dealt with several weeks after Sandy. The reliance on traditional sources of information (TV, radio, friends) found in this study suggests that the extreme power outages rendered web, cell phones, and social media on cell phones less usable, and suggests the need for an integrated communication strategy with redundancies that takes into account prolonged power outages over large geographical areas. PMID:24279815

  5. Minimizing forced outage risk in generator bidding

    NASA Astrophysics Data System (ADS)

    Das, Dibyendu

    Competition in power markets has exposed the participating companies to physical and financial uncertainties. Generator companies bid to supply power in a day-ahead market. Once their bids are accepted by the ISO they are bound to supply power. A random outage after acceptance of bids forces a generator to buy power from the expensive real-time hourly spot market and sell to the ISO at the set day-ahead market clearing price, incurring losses. A risk management technique is developed to assess this financial risk associated with forced outages of generators and then minimize it. This work presents a risk assessment module which measures the financial risk of generators bidding in an open market for different bidding scenarios. The day-ahead power market auction is modeled using a Unit Commitment algorithm and a combination of Normal and Cauchy distributions generate the real time hourly spot market. Risk profiles are derived and VaRs are calculated at 98 percent confidence level as a measure of financial risk. Risk Profiles and VaRs help the generators to analyze the forced outage risk and different factors affecting it. The VaRs and the estimated total earning for different bidding scenarios are used to develop a risk minimization module. This module will develop a bidding strategy of the generator company such that its estimated total earning is maximized keeping the VaR below a tolerable limit. This general framework of a risk management technique for the generating companies bidding in competitive day-ahead market can also help them in decisions related to building new generators.

  6. Trusted information sources used during and after Superstorm Sandy: TV and radio were used more often than social media.

    PubMed

    Burger, Joanna; Gochfeld, Michael; Jeitner, Christian; Pittfield, Taryn; Donio, Mark

    2013-01-01

    Health and safety professionals and the public are interested in the best methods of providing timely information about disasters. The objective of this study was to examine information sources used for Superstorm Sandy with respect to the storm, evacuation routes, shelters, safety, and health issues. Respondents in central New Jersey and Jersey shore communities were differentially impacted by the storm. Jersey shore respondents had higher evacuation rates (47% vs. 13%), higher flood waters in homes, longer power outages (average 23 vs. 6 d), and longer periods without Internet (29 vs. 6 d). Electricity outages disrupted both sources and receivers of communication. Both groups obtained most of their information regarding safety from television, radio, friends, and Web/e-mail. Information sources on health varied by location, with central Jersey respondents using mainly TV and the Web, and Jersey shore respondents obtaining health information from the radio and TV (before the storm). For information on evacuation routes, Jersey shore respondents obtained information from many sources, while central Jersey respondents obtained it from TV. Information on mold was largely obtained from friends and the Web, since mold issues were dealt with several weeks after Sandy. The reliance on traditional sources of information (TV, radio, friends) found in this study suggests that the extreme power outages rendered Web, cell phones, and social media on cell phones less usable, and suggests the need for an integrated communication strategy with redundancies that takes into account prolonged power outages over large geographical areas.

  7. Field experience with remote monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desrosiers, A.E.

    1995-03-01

    The Remote Monitoring System (RMS) is a combination of Merlin Gerin detection hardware, digital data communications hardware, and computer software from Bartlett Services, Inc. (BSI) that can improve the conduct of reactor plant operations in several areas. Using the RMS can reduce radiation exposures to radiation protection technicians (RPTs), reduce radiation exposures to plant maintenance and operations personnel, and reduce the time required to complete maintenance and inspections during outages. The number of temporary RPTs required during refueling outages can also be reduced. Data from use of the RMS at a two power plants are presented to illustrate these points.

  8. Characterization of Nighttime Light Variability Over the Southeastern United States

    NASA Technical Reports Server (NTRS)

    Cole, Tony A.; Molthan, Andrew L.; Schultz, Lori A.

    2016-01-01

    City lights provide indications of human activity at night. Nighttime satellite imagery offers daily snapshots of this activity. With calibrated, science-quality imagery, long-term monitoring can also be achieved. The degree to which city lights fluctuate, however, is not well known. For the application of detecting power outages, this degree of variability is crucial for assessing reductions to city lights based on historical trends. Eight southeastern U.S. cities are analyzed to understand the relationship between emission variability and several population centers. A preliminary, example case power outage study is also discussed as a transition into future work.

  9. Characteristics of health IT outage and suggested risk management strategies: an analysis of historical incident reports in China.

    PubMed

    Lei, Jianbo; Guan, Pengcheng; Gao, Kaihua; Lu, Xueqin; Chen, Yunan; Li, Yuefeng; Meng, Qun; Zhang, Jiajie; Sittig, Dean F; Zheng, Kai

    2014-02-01

    The healthcare industry has become increasingly dependent on using information technology (IT) to manage its daily operations. Unexpected downtime of health IT systems could therefore wreak havoc and result in catastrophic consequences. Little is known, however, regarding the nature of failures of health IT. To analyze historical health IT outage incidents as a means to better understand health IT vulnerabilities and inform more effective prevention and emergency response strategies. We studied news articles and incident reports publicly available on the internet describing health IT outage events that occurred in China. The data were qualitatively analyzed using a deductive grounded theory approach based on a synthesized IT risk model developed in the domain of information systems. A total of 116 distinct health IT incidents were identified. A majority of them (69.8%) occurred in the morning; over 50% caused disruptions to the patient registration and payment collection functions of the affected healthcare facilities. The outpatient practices in tertiary hospitals seem to be particularly vulnerable to IT failures. Software defects and overcapacity issues, followed by malfunctioning hardware, were among the principal causes. Unexpected health IT downtime occurs more and more often with the widespread adoption of electronic systems in healthcare. Risk identification and risk assessments are essential steps to developing preventive measures. Equally important is institutionalization of contingency plans as our data show that not all failures of health IT can be predicted and thus effectively prevented. The results of this study also suggest significant future work is needed to systematize the reporting of health IT outage incidents in order to promote transparency and accountability. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Reciprocally-Benefited Secure Transmission for Spectrum Sensing-Based Cognitive Radio Sensor Networks

    PubMed Central

    Wang, Dawei; Ren, Pinyi; Du, Qinghe; Sun, Li; Wang, Yichen

    2016-01-01

    The rapid proliferation of independently-designed and -deployed wireless sensor networks extremely crowds the wireless spectrum and promotes the emergence of cognitive radio sensor networks (CRSN). In CRSN, the sensor node (SN) can make full use of the unutilized licensed spectrum, and the spectrum efficiency is greatly improved. However, inevitable spectrum sensing errors will adversely interfere with the primary transmission, which may result in primary transmission outage. To compensate the adverse effect of spectrum sensing errors, we propose a reciprocally-benefited secure transmission strategy, in which SN’s interference to the eavesdropper is employed to protect the primary confidential messages while the CRSN is also rewarded with a loose spectrum sensing error probability constraint. Specifically, according to the spectrum sensing results and primary users’ activities, there are four system states in this strategy. For each state, we analyze the primary secrecy rate and the SN’s transmission rate by taking into account the spectrum sensing errors. Then, the SN’s transmit power is optimally allocated for each state so that the average transmission rate of CRSN is maximized under the constraint of the primary maximum permitted secrecy outage probability. In addition, the performance tradeoff between the transmission rate of CRSN and the primary secrecy outage probability is investigated. Moreover, we analyze the primary secrecy rate for the asymptotic scenarios and derive the closed-form expression of the SN’s transmission outage probability. Simulation results show that: (1) the performance of the SN’s average throughput in the proposed strategy outperforms the conventional overlay strategy; (2) both the primary network and CRSN benefit from the proposed strategy. PMID:27897988

  11. Evaluation on the impact of IMU grades on BDS + GPS PPP/INS tightly coupled integration

    NASA Astrophysics Data System (ADS)

    Gao, Zhouzheng; Ge, Maorong; Shen, Wenbin; Li, You; Chen, Qijin; Zhang, Hongping; Niu, Xiaoji

    2017-09-01

    The unexpected observing environments in dynamic applications may lead to partial and/or complete satellite signal outages frequently, which can definitely impact on the positioning performance of the Precise Point Positioning (PPP) in terms of decreasing available satellite numbers, breaking the continuity of observations, and degrading PPP's positioning accuracy. Generally, both the Inertial Navigation System (INS) and the multi-constellation Global Navigation Satellite System (GNSS) can be used to enhance the performance of PPP. This paper introduces the mathematical models of the multi-GNSS PPP/INS Tightly Coupled Integration (TCI), and investigates its performance from several aspects. Specifically, it covers (1) the use of the BDS/GPS PPP, PPP/INS, and their combination; (2) three positioning modes including PPP, PPP/INS TCI, and PPP/INS Loosely Coupled Integration (LCI); (3) the use of four various INS systems named navigation grade, tactical grade, auto grade, and Micro-Electro-Mechanical-Sensors (MEMS) one; (4) three PPP observation scenarios including PPP available, partially available, and fully outage. According to the statistics results, (1) the positioning performance of the PPP/INS (either TCI or LCI) mode is insignificantly depended on the grade of inertial sensor, when there are enough available satellites; (2) after the complete GNSS outages, the TCI mode expresses both higher convergence speed and more accurate positioning solutions than the LCI mode. Furthermore, in the TCI mode, using a higher grade inertial sensor is beneficial for the PPP convergence; (3) under the partial GNSS outage situations, the PPP/INS TCI mode position divergence speed is also restrained significantly; and (4) the attitude determination accuracy of the PPP/INS integration is highly correlated with the grade of inertial sensor.

  12. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1. Volume 5: Analysis of core damage frequency from seismic events for plant operational state 5 during a refueling outage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Budnitz, R.J.; Davis, P.R.; Ravindra, M.K.

    In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Sandia National Laboratories studying a boiling water reactor (Grand Gulf), and the other at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1). Both the Sandia and Brookhaven projects have examined only accidents initiated by internal plant faults---so-called ``internal initiators.`` This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling outage conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. Thismore » report covers the seismic analysis at Grand Gulf. All of the many systems modeling assumptions, component non-seismic failure rates, and human effort rates that were used in the internal-initiator study at Grand Gulf have been adopted here, so that the results of the study can be as comparable as possible. Both the Sandia study and this study examine only one shutdown plant operating state (POS) at Grand Gulf, namely POS 5 representing cold shutdown during a refueling outage. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POS 5. The results of the analysis are that the core-damage frequency for earthquake-initiated accidents during refueling outages in POS 5 is found to be quite low in absolute terms, less than 10{sup {minus}7}/year.« less

  13. Relay Selection for Cooperative Relaying in Wireless Energy Harvesting Networks

    NASA Astrophysics Data System (ADS)

    Zhu, Kaiyan; Wang, Fei; Li, Songsong; Jiang, Fengjiao; Cao, Lijie

    2018-01-01

    Energy harvesting from the surroundings is a promising solution to provide energy supply and extend the life of wireless sensor networks. Recently, energy harvesting has been shown as an attractive solution to prolong the operation of cooperative networks. In this paper, we propose a relay selection scheme to optimize the amplify-and-forward (AF) cooperative transmission in wireless energy harvesting cooperative networks. The harvesting energy and channel conditions are considered to select the optimal relay as cooperative relay to minimize the outage probability of the system. Simulation results show that our proposed relay selection scheme achieves better outage performance than other strategies.

  14. Optimal Power Allocation for CC-HARQ-based Cognitive Radio with Statistical CSI in Nakagami Slow Fading Channels

    NASA Astrophysics Data System (ADS)

    Xu, Ding; Li, Qun

    2017-01-01

    This paper addresses the power allocation problem for cognitive radio (CR) based on hybrid-automatic-repeat-request (HARQ) with chase combining (CC) in Nakagamimslow fading channels. We assume that, instead of the perfect instantaneous channel state information (CSI), only the statistical CSI is available at the secondary user (SU) transmitter. The aim is to minimize the SU outage probability under the primary user (PU) interference outage constraint. Using the Lagrange multiplier method, an iterative and recursive algorithm is derived to obtain the optimal power allocation for each transmission round. Extensive numerical results are presented to illustrate the performance of the proposed algorithm.

  15. Exploiting Outage and Error Probability of Cooperative Incremental Relaying in Underwater Wireless Sensor Networks

    PubMed Central

    Nasir, Hina; Javaid, Nadeem; Sher, Muhammad; Qasim, Umar; Khan, Zahoor Ali; Alrajeh, Nabil; Niaz, Iftikhar Azim

    2016-01-01

    This paper embeds a bi-fold contribution for Underwater Wireless Sensor Networks (UWSNs); performance analysis of incremental relaying in terms of outage and error probability, and based on the analysis proposition of two new cooperative routing protocols. Subject to the first contribution, a three step procedure is carried out; a system model is presented, the number of available relays are determined, and based on cooperative incremental retransmission methodology, closed-form expressions for outage and error probability are derived. Subject to the second contribution, Adaptive Cooperation in Energy (ACE) efficient depth based routing and Enhanced-ACE (E-ACE) are presented. In the proposed model, feedback mechanism indicates success or failure of data transmission. If direct transmission is successful, there is no need for relaying by cooperative relay nodes. In case of failure, all the available relays retransmit the data one by one till the desired signal quality is achieved at destination. Simulation results show that the ACE and E-ACE significantly improves network performance, i.e., throughput, when compared with other incremental relaying protocols like Cooperative Automatic Repeat reQuest (CARQ). E-ACE and ACE achieve 69% and 63% more throughput respectively as compared to CARQ in hard underwater environment. PMID:27420061

  16. Long-Term Tracking of a Specific Vehicle Using Airborne Optical Camera Systems

    NASA Astrophysics Data System (ADS)

    Kurz, F.; Rosenbaum, D.; Runge, H.; Cerra, D.; Mattyus, G.; Reinartz, P.

    2016-06-01

    In this paper we present two low cost, airborne sensor systems capable of long-term vehicle tracking. Based on the properties of the sensors, a method for automatic real-time, long-term tracking of individual vehicles is presented. This combines the detection and tracking of the vehicle in low frame rate image sequences and applies the lagged Cell Transmission Model (CTM) to handle longer tracking outages occurring in complex traffic situations, e.g. tunnels. The CTM model uses the traffic conditions in the proximities of the target vehicle and estimates its motion to predict the position where it reappears. The method is validated on an airborne image sequence acquired from a helicopter. Several reference vehicles are tracked within a range of 500m in a complex urban traffic situation. An artificial tracking outage of 240m is simulated, which is handled by the CTM. For this, all the vehicles in the close proximity are automatically detected and tracked to estimate the basic density-flow relations of the CTM model. Finally, the real and simulated trajectories of the reference vehicles in the outage are compared showing good correspondence also in congested traffic situations.

  17. Automation of steam generator services at public service electric & gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cruickshank, H.; Wray, J.; Scull, D.

    1995-03-01

    Public Service Electric & Gas takes an aggressive approach to pursuing new exposure reduction techniques. Evaluation of historic outage exposure shows that over the last eight refueling outages, primary steam generator work has averaged sixty-six (66) person-rem, or, approximately tewenty-five percent (25%) of the general outage exposure at Salem Station. This maintenance evolution represents the largest percentage of exposure for any single activity. Because of this, primary steam generator work represents an excellent opportunity for the development of significant exposure reduction techniques. A study of primary steam generator maintenance activities demonstrated that seventy-five percent (75%) of radiation exposure was duemore » to work activities of the primary steam generator platform, and that development of automated methods for performing these activities was worth pursuing. Existing robotics systems were examined and it was found that a new approach would have to be developed. This resulted in a joint research and development project between Westinghouse and Public Service Electric & Gas to develop an automated system of accomplishing the Health Physics functions on the primary steam generator platform. R.O.M.M.R.S. (Remotely Operated Managed Maintenance Robotics System) was the result of this venture.« less

  18. Performance analysis of an IMU-augmented GNSS tracking system on board the MAIUS-1 sounding rocket

    NASA Astrophysics Data System (ADS)

    Braun, Benjamin; Grillenberger, Andreas; Markgraf, Markus

    2018-05-01

    Satellite navigation receivers are adequate tracking sensors for range safety of both orbital launch vehicles and suborbital sounding rockets. Due to high accuracy and its low system complexity, satellite navigation is seen as well-suited supplement or replacement of conventional tracking systems like radar. Having the well-known shortcomings of satellite navigation like deliberate or unintentional interferences in mind, it is proposed to augment the satellite navigation receiver by an inertial measurement unit (IMU) to enhance continuity and availability of localization. The augmented receiver is thus enabled to output at least an inertial position solution in case of signal outages. In a previous study, it was shown by means of simulation using the example of Ariane 5 that the performance of a low-grade microelectromechanical IMU is sufficient to bridge expected outages of some ten seconds, and still meeting the range safety requirements in effect. In this publication, these theoretical findings shall be substantiated by real flight data that were recorded on MAIUS-1, a sounding rocket launched from Esrange, Sweden, in early 2017. The analysis reveals that the chosen representative of a microelectromechanical IMU is suitable to bridge outages of up to thirty seconds.

  19. Placement of Synchronized Measurements for Power System Observability during Cascaded Outages

    NASA Astrophysics Data System (ADS)

    Thirugnanasambandam, Venkatesh; Jain, Trapti

    2017-11-01

    Cascaded outages often result in power system islanding followed by a blackout and therefore considered as a severe disturbance. Maintaining the observability of each island may help in taking proper control actions to preserve the stability of individual islands thus, averting system collapse. With this intent, a strategy for placement of synchronized measurements, which can be obtained from phasor measurement units (PMU), has been proposed in this paper to keep the system observable during cascaded outages also. Since, all the cascaded failures may not lead to islanding situations, therefore, failures leading to islanding as well as non-islanding situations have been considered. A topology based algorithm has been developed to identify the islanding/non-islanding condition created by a particular cascaded event. Additional contingencies such as single line loss and single PMU failure have also been considered after the occurrence of cascaded events. The proposed method is further extended to incorporate the measurement redundancy, which is desirable for a reliable state estimation. The proposed scheme is tested on IEEE 14-bus, IEEE 30-bus and a practical Indian 246-bus networks. The numerical results ensure the observability of the power system under system intact as well as during cascaded islanding and non-islanding disturbances.

  20. Valuing the Resilience Provided by Solar and Battery Energy Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLaren, Joyce A; Mullendore, Seth; Laws, Nicholas D

    This paper explores the impact of valuing resilience on the economics of photovoltaics (PV) and storage systems for commercial buildings. The analysis presented here illustrates that accounting for the cost of grid power outages can change the breakeven point for PV and storage system investment, and increase the size of systems designed to deliver the greatest economic benefit over time. In other words, valuing resilience can make PV and storage systems economical in cases where they would not be otherwise. As storage costs decrease, and outages occur more frequently, PV and storage are likely to play a larger role inmore » building design and management considerations.« less

  1. High-Rate Communications Outage Recorder Operations for Optimal Payload and Science Telemetry Management Onboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Shell, Michael T.; McElyea, Richard M. (Technical Monitor)

    2002-01-01

    All International Space Station (ISS) Ku-band telemetry transmits through the High-Rate Communications Outage Recorder (HCOR). The HCOR provides the recording and playback capability for all payload, science, and International Partner data streams transmitting through NASA's Ku-band antenna system. The HCOR is a solid-state memory recorder that provides recording capability to record all eight ISS high-rate data during ISS Loss-of-Signal periods. NASA payloads in the Destiny module are prime users of the HCOR; however, NASDA and ESA will also utilize the HCOR for data capture and playback of their high data rate links from the Kibo and Columbus modules. Marshall Space Flight Center's Payload Operations Integration Center manages the HCOR for nominal functions, including system configurations and playback operations. The purpose of this paper is to present the nominal operations plan for the HCOR and the plans for handling contingency operations affecting payload operations. In addition, the paper will address HCOR operation limitations and the expected effects on payload operations. The HCOR is manifested for ISS delivery on flight 9A with the HCOR backup manifested on flight 11A. The HCOR replaces the Medium-Rate Communications Outage Recorder (MCOR), which has supported payloads since flight 5A.1.

  2. Impact of nonzero boresight pointing errors on the performance of a relay-assisted free-space optical communication system over exponentiated Weibull fading channels.

    PubMed

    Wang, Ping; Liu, Xiaoxia; Cao, Tian; Fu, Huihua; Wang, Ranran; Guo, Lixin

    2016-09-20

    The impact of nonzero boresight pointing errors on the system performance of decode-and-forward protocol-based multihop parallel optical wireless communication systems is studied. For the aggregated fading channel, the atmospheric turbulence is simulated by an exponentiated Weibull model, and pointing errors are described by one recently proposed statistical model including both boresight and jitter. The binary phase-shift keying subcarrier intensity modulation-based analytical average bit error rate (ABER) and outage probability expressions are achieved for a nonidentically and independently distributed system. The ABER and outage probability are then analyzed with different turbulence strengths, receiving aperture sizes, structure parameters (P and Q), jitter variances, and boresight displacements. The results show that aperture averaging offers almost the same system performance improvement with boresight included or not, despite the values of P and Q. The performance enhancement owing to the increase of cooperative path (P) is more evident with nonzero boresight than that with zero boresight (jitter only), whereas the performance deterioration because of the increasing hops (Q) with nonzero boresight is almost the same as that with zero boresight. Monte Carlo simulation is offered to verify the validity of ABER and outage probability expressions.

  3. Smart distribution systems

    DOE PAGES

    Jiang, Yazhou; Liu, Chen -Ching; Xu, Yin

    2016-04-19

    The increasing importance of system reliability and resilience is changing the way distribution systems are planned and operated. To achieve a distribution system self-healing against power outages, emerging technologies and devices, such as remote-controlled switches (RCSs) and smart meters, are being deployed. The higher level of automation is transforming traditional distribution systems into the smart distribution systems (SDSs) of the future. The availability of data and remote control capability in SDSs provides distribution operators with an opportunity to optimize system operation and control. In this paper, the development of SDSs and resulting benefits of enhanced system capabilities are discussed. Amore » comprehensive survey is conducted on the state-of-the-art applications of RCSs and smart meters in SDSs. Specifically, a new method, called Temporal Causal Diagram (TCD), is used to incorporate outage notifications from smart meters for enhanced outage management. To fully utilize the fast operation of RCSs, the spanning tree search algorithm is used to develop service restoration strategies. Optimal placement of RCSs and the resulting enhancement of system reliability are discussed. Distribution system resilience with respect to extreme events is presented. Furthermore, test cases are used to demonstrate the benefit of SDSs. Active management of distributed generators (DGs) is introduced. Future research in a smart distribution environment is proposed.« less

  4. BWR Servicing and Refueling Improvement Program: Phase I summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perry, D.R.

    1978-09-01

    Under the U.S. Department of Energy sponsorship, General Electric Co. (GE) undertook a study of boiling water reactor (BWR) refueling outages for the purpose of recommending the development and demonstration of critical path time savings improvements. The Tennessee Valley Authority (TVA) joined the study as a subcontractor, providing monitoring assistance and making the Browns Ferry Site available for improvement demonstrations. Agreement was also reached with Georgia Power Co., Power Authority of the State of New York, and Commonwealth Edison Co. for monitoring and data collection at Hatch 1, FitzPatrick, and Quad Cities 1 nuclear plants, respectively. The objective was tomore » identify, develop, and demonstrate improved refueling, maintenance, and inspection procedures and equipment. The improvements recommended in this study are applicable to BWR nuclear plants currently in operation as well as those in the design and construction phases. The recommendations and outage information can be used as a basis to plan and conduct the first outages of new plants and to improve the planning and facilities of currently operating plants. Many of the recommendations can readily be incorporated in plants currently in the design and construction phases as well as in the design of future plants. Many of these recommended improvements can be implemented immediately by utilities without further technical development.« less

  5. Knowledge to Action - Understanding Natural Hazards-Induced Power Outage Scenarios for Actionable Disaster Responses

    NASA Astrophysics Data System (ADS)

    Kar, B.; Robinson, C.; Koch, D. B.; Omitaomu, O.

    2017-12-01

    The Sendai Framework for Disaster Risk Reduction 2015-2030 identified the following four priorities to prevent and reduce disaster risks: i) understanding disaster risk; ii) strengthening governance to manage disaster risk; iii) investing in disaster risk reduction for resilience and; iv) enhancing disaster preparedness for effective response, and to "Build Back Better" in recovery, rehabilitation and reconstruction. While forecasting and decision making tools are in place to predict and understand future impacts of natural hazards, the knowledge to action approach that currently exists fails to provide updated information needed by decision makers to undertake response and recovery efforts following a hazard event. For instance, during a tropical storm event advisories are released every two to three hours, but manual analysis of geospatial data to determine potential impacts of the event tends to be time-consuming and a post-event process. Researchers at Oak Ridge National Laboratory have developed a Spatial Decision Support System that enables real-time analysis of storm impact based on updated advisory. A prototype of the tool that focuses on determining projected power outage areas and projected duration of outages demonstrates the feasibility of integrating science with decision making for emergency management personnel to act in real time to protect communities and reduce risk.

  6. Terrestrial Energy Storage SPS Systems

    NASA Technical Reports Server (NTRS)

    Brandhorst, Henry W., Jr.

    1998-01-01

    Terrestrial energy storage systems for the SSP system were evaluated that could maintain the 1.2 GW power level during periods of brief outages from the solar powered satellite (SPS). Short-term outages of ten minutes and long-term outages up to four hours have been identified as "typical" cases where the ground-based energy storage system would be required to supply power to the grid. These brief interruptions in transmission could result from performing maintenance on the solar power satellite or from safety considerations necessitating the power beam be turned off. For example, one situation would be to allow for the safe passage of airplanes through the space occupied by the beam. Under these conditions, the energy storage system needs to be capable of storing 200 MW-hrs and 4.8 GW-hrs, respectively. The types of energy storage systems to be considered include compressed air energy storage, inertial energy storage, electrochemical energy storage, superconducting magnetic energy storage, and pumped hydro energy storage. For each of these technologies, the state-of-the-art in terms of energy and power densities were identified as well as the potential for scaling to the size systems required by the SSP system. Other issues addressed included the performance, life expectancy, cost, and necessary infrastructure and site locations for the various storage technologies.

  7. A smart Monte Carlo procedure for production costing and uncertainty analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, C.; Stremel, J.

    1996-11-01

    Electric utilities using chronological production costing models to decide whether to buy or sell power over the next week or next few weeks need to determine potential profits or losses under a number of uncertainties. A large amount of money can be at stake--often $100,000 a day or more--and one party of the sale must always take on the risk. In the case of fixed price ($/MWh) contracts, the seller accepts the risk. In the case of cost plus contracts, the buyer must accept the risk. So, modeling uncertainty and understanding the risk accurately can improve the competitive edge ofmore » the user. This paper investigates an efficient procedure for representing risks and costs from capacity outages. Typically, production costing models use an algorithm based on some form of random number generator to select resources as available or on outage. These algorithms allow experiments to be repeated and gains and losses to be observed in a short time. The authors perform several experiments to examine the capability of three unit outage selection methods and measures their results. Specifically, a brute force Monte Carlo procedure, a Monte Carlo procedure with Latin Hypercube sampling, and a Smart Monte Carlo procedure with cost stratification and directed sampling are examined.« less

  8. Impact of Distributed Energy Resources on the Reliability of a Critical Telecommunications Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, D.; Atcitty, C.; Zuffranieri, J.

    2006-03-01

    Telecommunications has been identified by the Department of Homeland Security as a critical infrastructure to the United States. Failures in the power systems supporting major telecommunications service nodes are a main contributor to major telecommunications outages, as documented by analyses of Federal Communications Commission (FCC) outage reports by the National Reliability Steering Committee (under auspices of the Alliance for Telecommunications Industry Solutions). There are two major issues that are having increasing impact on the sensitivity of the power distribution to telecommunication facilities: deregulation of the power industry, and changing weather patterns. A logical approach to improve the robustness of telecommunicationmore » facilities would be to increase the depth and breadth of technologies available to restore power in the face of power outages. Distributed energy resources such as fuel cells and gas turbines could provide one more onsite electric power source to provide backup power, if batteries and diesel generators fail. But does the diversity in power sources actually increase the reliability of offered power to the office equipment, or does the complexity of installing and managing the extended power system induce more potential faults and higher failure rates? This report analyzes a system involving a telecommunications facility consisting of two switch-bays and a satellite reception system.« less

  9. A Study of the Impact of Peak Demand on Increasing Vulnerability of Cascading Failures to Extreme Contingency Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vyakaranam, Bharat GNVSR; Vallem, Mallikarjuna R.; Nguyen, Tony B.

    The vulnerability of large power systems to cascading failures and major blackouts has become evident since the Northeast blackout in 1965. Based on analyses of the series of cascading blackouts in the past decade, the research community realized the urgent need to develop better methods, tools, and practices for performing cascading-outage analysis and for evaluating mitigations that are easily accessible by utility planning engineers. PNNL has developed the Dynamic Contingency Analysis Tool (DCAT) as an open-platform and publicly available methodology to help develop applications that aim to improve the capabilities of power planning engineers to assess the impact and likelihoodmore » of extreme contingencies and potential cascading events across their systems and interconnections. DCAT analysis will help identify potential vulnerabilities and allow study of mitigation solutions to reduce the risk of cascading outages in technically sound and effective ways. Using the DCAT capability, we examined the impacts of various load conditions to identify situations in which the power grid may encounter cascading outages that could lead to potential blackouts. This paper describes the usefulness of the DCAT tool and how it helps to understand potential impacts of load demand on cascading failures on the power system.« less

  10. Component Repair Times Obtained from MSPI Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eide, Steven A.; Cadwallader, Lee

    Information concerning times to repair or restore equipment to service given a failure is valuable to probabilistic risk assessments (PRAs). Examples of such uses in modern PRAs include estimation of the probability of failing to restore a failed component within a specified time period (typically tied to recovering a mitigating system before core damage occurs at nuclear power plants) and the determination of mission times for support system initiating event (SSIE) fault tree models. Information on equipment repair or restoration times applicable to PRA modeling is limited and dated for U.S. commercial nuclear power plants. However, the Mitigating Systems Performancemore » Index (MSPI) program covering all U.S. commercial nuclear power plants provides up-to-date information on restoration times for a limited set of component types. This paper describes the MSPI program data available and analyzes the data to obtain median and mean component restoration times as well as non-restoration cumulative probability curves. The MSPI program provides guidance for monitoring both planned and unplanned outages of trains of selected mitigating systems deemed important to safety. For systems included within the MSPI program, plants monitor both train UA and component unreliability (UR) against baseline values. If the combined system UA and UR increases sufficiently above established baseline results (converted to an estimated change in core damage frequency or CDF), a “white” (or worse) indicator is generated for that system. That in turn results in increased oversight by the US Nuclear Regulatory Commission (NRC) and can impact a plant’s insurance rating. Therefore, there is pressure to return MSPI program components to service as soon as possible after a failure occurs. Three sets of unplanned outages might be used to determine the component repair durations desired in this article: all unplanned outages for the train type that includes the component of interest, only unplanned outages associated with failures of the component of interest, and only unplanned outages associated with PRA failures of the component of interest. The paper will describe how component repair times can be generated from each set and which approach is most applicable. Repair time information will be summarized for MSPI pumps and diesel generators using data over 2003 – 2007. Also, trend information over 2003 – 2012 will be presented to indicate whether the 2003 – 2007 repair time information is still considered applicable. For certain types of pumps, mean repair times are significantly higher than the typically assumed 24 h duration.« less

  11. Packaging, Transportation and Recycling of NPP Condenser Modules - 12262

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polley, G.M.

    2012-07-01

    Perma-Fix was awarded contract from Energy Northwest for the packaging, transportation and disposition of the condenser modules, water boxes and miscellaneous metal, combustibles and water generated during the 2011 condenser replacement outage at the Columbia Generating Station. The work scope was to package the water boxes and condenser modules as they were removed from the facility and transfer them to the Perma-Fix Northwest facility for processing, recycle of metals and disposition. The condenser components were oversized and overweight (the condenser modules weighed ∼102,058 kg [225,000 lb]) which required special equipment for loading and transport. Additional debris waste was packaged inmore » inter-modals and IP-1 boxes for transport. A waste management plan was developed to minimize the generation of virtually any waste requiring landfill disposal. The Perma-Fix Northwest facility was modified to accommodate the ∼15 m [50-ft] long condenser modules and equipment was designed and manufactured to complete the disassembly, decontamination and release survey. The condenser modules are currently undergoing processing for free release to a local metal recycler. Over three millions pounds of metal will be recycled and over 95% of the waste generated during this outage will not require land disposal. There were several elements of this project that needed to be addressed during the preparation for this outage and the subsequent packaging, transportation and processing. - Staffing the project to support 24/7 generation of large components and other wastes. - The design and manufacture of the soft-sided shipping containers for the condenser modules that measured ∼15 m X 4 m X 3 m [50 ft X 13 ft X 10 ft] and weighed ∼102,058 kg [225,000 lbs] - Developing a methodology for loading the modules into the shipping containers. - Obtaining a transport vehicle for the modules. - Designing and modifying the processing facility. - Movement of the modules at the processing facility. If any of these issues were not adequately resolved prior to the start of the outage, costly delays would result and the re-start of the power plant could be impacted. The main focus of this project was to find successful methods for keeping this material out of the landfills and preserving the natural resources. In addition, this operation provided a significant cost savings to the public utility by minimizing landfill disposal. The onsite portion of the project has been completed without impact to the overall outage schedule. By the date of presentation, the majority of the waste from the condenser replacement project will have been processed and recycled. The goals for this project included helping Energy Northwest maintain the outage schedule, package and characterize waste compliantly, perform transportation activities in compliance with 49CFR (Ref-1), and minimize the waste disposal volume. During this condenser replacement project, over three millions pounds of waste was generated, packaged, characterized and transported without injury or incident. It is anticipated that 95% of the waste generated during this project will not require landfill disposal. All of the waste is scheduled to be processed, decontaminated and recycled by June of 2012. (authors)« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The report provides highlights related to impacts of Hurricane Frances and Hurricane Ivan in the Florida area. Sections on electric information, oil and gas information, and county outage data are provided.

  13. VERDE Analytic Modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2008-01-15

    The Verde Analytic Modules permit the user to ingest openly available data feeds about phenomenology (storm tracks, wind, precipitation, earthquake, wildfires, and similar natural and manmade power grid disruptions and forecast power outages, restoration times, customers outaged, and key facilities that will lose power. Damage areas are predicted using historic damage criteria of the affected area. The modules use a cellular automata approach to estimating the distribution circuits assigned to geo-located substations. Population estimates served within the service areas are located within 1 km grid cells and converted to customer counts by conversion through demographic estimation of households and commercialmore » firms within the population cells. Restoration times are estimated by agent-based simulation of restoration crews working according to utility published prioritization calibrated by historic performance.« less

  14. Cluster Cooperation in Wireless-Powered Sensor Networks: Modeling and Performance Analysis.

    PubMed

    Zhang, Chao; Zhang, Pengcheng; Zhang, Weizhan

    2017-09-27

    A wireless-powered sensor network (WPSN) consisting of one hybrid access point (HAP), a near cluster and the corresponding far cluster is investigated in this paper. These sensors are wireless-powered and they transmit information by consuming the harvested energy from signal ejected by the HAP. Sensors are able to harvest energy as well as store the harvested energy. We propose that if sensors in near cluster do not have their own information to transmit, acting as relays, they can help the sensors in a far cluster to forward information to the HAP in an amplify-and-forward (AF) manner. We use a finite Markov chain to model the dynamic variation process of the relay battery, and give a general analyzing model for WPSN with cluster cooperation. Though the model, we deduce the closed-form expression for the outage probability as the metric of this network. Finally, simulation results validate the start point of designing this paper and correctness of theoretical analysis and show how parameters have an effect on system performance. Moreover, it is also known that the outage probability of sensors in far cluster can be drastically reduced without sacrificing the performance of sensors in near cluster if the transmit power of HAP is fairly high. Furthermore, in the aspect of outage performance of far cluster, the proposed scheme significantly outperforms the direct transmission scheme without cooperation.

  15. Task related doses in Spanish pressurized water reactors over the period 1988-1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O`Donnell, P.; Labarta, T.; Amor, I.

    1995-03-01

    In order to evaluate in depth the collective dose trend and its correlation with the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities, and base the different policy lines to promote this criteria, the CSN has fullfilled an analysis of the task related doses data over the period 1988-1992. Previously, the CSN had required to the utilities the compilation of their refuelling outage collective dose from 1988 according with a predeterminate number of tasks, in order to have available a representative and retrospective set of data in an homogeneous way and coherent with the internationalmore » data banks on occupational exposure in NPP, as the CEC and the NEA ones. The scope of this analysis was the following: first, the collective dose summaries for outage tasks and departments for PWR and for BWR, including the minimum, maximum and average dose (and statistics data) for 18 different refuelling outage tasks and 12 personal departments for each generation of each type of rector, the task and department related collective dose trends in each plant and in each generation, and second, the dose reduction techniques having been used during that period in each plant and the relative level of adoption. In this presentation the main results and conclusions of the first part of the study are reviewed for PWR.« less

  16. Cluster Cooperation in Wireless-Powered Sensor Networks: Modeling and Performance Analysis

    PubMed Central

    Zhang, Chao; Zhang, Pengcheng; Zhang, Weizhan

    2017-01-01

    A wireless-powered sensor network (WPSN) consisting of one hybrid access point (HAP), a near cluster and the corresponding far cluster is investigated in this paper. These sensors are wireless-powered and they transmit information by consuming the harvested energy from signal ejected by the HAP. Sensors are able to harvest energy as well as store the harvested energy. We propose that if sensors in near cluster do not have their own information to transmit, acting as relays, they can help the sensors in a far cluster to forward information to the HAP in an amplify-and-forward (AF) manner. We use a finite Markov chain to model the dynamic variation process of the relay battery, and give a general analyzing model for WPSN with cluster cooperation. Though the model, we deduce the closed-form expression for the outage probability as the metric of this network. Finally, simulation results validate the start point of designing this paper and correctness of theoretical analysis and show how parameters have an effect on system performance. Moreover, it is also known that the outage probability of sensors in far cluster can be drastically reduced without sacrificing the performance of sensors in near cluster if the transmit power of HAP is fairly high. Furthermore, in the aspect of outage performance of far cluster, the proposed scheme significantly outperforms the direct transmission scheme without cooperation. PMID:28953231

  17. The optical communication link outage probability in satellite formation flying

    NASA Astrophysics Data System (ADS)

    Arnon, Shlomi; Gill, Eberhard

    2014-02-01

    In recent years, several space systems consisting of multiple satellites flying in close formation have been proposed for various purposes such as interferometric synthetic aperture radar measurement (TerraSAR-X and the TanDEM-X), detecting extra-solar earth-like planets (Terrestrial Planet Finder-TPF and Darwin), and demonstrating distributed space systems (DARPA F6 project). Another important purpose, which is the concern of this paper, is for improving radio frequency communication to mobile terrestrial and maritime subscribers. In this case, radio frequency signals from several satellites coherently combine such that the received/transmit signal strength is increased proportionally with the number of satellites in the formation. This increase in signal strength allows to enhance the communication data rate and/or to reduce energy consumption and the antenna size of terrestrial mobile users' equipment. However, a coherent combination of signals without aligning the phases of the individual communication signals interrupts the communication and outage link between the satellites and the user. The accuracy of the phase estimation is a function of the inter-satellite laser ranging system performance. This paper derives an outage probability model of a coherent combination communication system as a function of the pointing vibration and jitter statistics of an inter-satellite laser ranging system tool. The coherent combination probability model, which could be used to improve the communication to mobile subscribers in air, sea and ground is the main importance of this work.

  18. What Happened to Our Environment and Mental Health as a Result of Hurricane Sandy?

    PubMed

    Lin, Shao; Lu, Yi; Justino, John; Dong, Guanghui; Lauper, Ursula

    2016-06-01

    This study describes findings of the impacts of Hurricane Sandy on environmental factors including power outages, air quality, water quality, and weather factors and how these affected mental health during the hurricane. An ecological study was conducted at the county level to describe changes in environmental factors-especially power outages-and their relationships to emergency department (ED) visits for mental health problems by use of a Poisson regression model. We found that many environmental hazards occurred as co-exposures during Hurricane Sandy in addition to flooding. Mental health ED visits corresponded with the peak of maximum daily power blackouts, with a 3-day lag, and were positively associated with power blackouts in Bronx (prevalence ratio [PR]: 8.82, 95% confidence interval [CI]: 1.27-61.42) and Queens (PR: 2.47, 95% CI: 1.05-5.82) counties. A possible dose-response relationship was found between the quantile of maximum blackout percentage and the risk of mental health in the Bronx. We found that multiple co-environmental hazards occurred during Hurricane Sandy, especially power blackouts that mediated this disaster's impacts. The effects of power outage on mental health had large geographic variations and were substantial, especially in communities with low sociodemographic status. These findings may provide new insights for future disaster response and preparedness efforts. (Disaster Med Public Health Preparedness. 2016;10:314-319).

  19. Metallurgical evaluation of a feedwater nozzle to safe-end weld

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowerman, B.S.; Czajkowski, C.J.; Roberts, T.C.

    1999-11-01

    Weld cracks in safety class systems are a serious concern, because these systems are part of the primary barrier providing containment of radioactive coolant. Loss of weld integrity yields leaks, or, under catastrophic failure, can be the basis for a severe loss of coolant accident. A circumferential indication was found by ultrasonic examination (UT) in the N4A-2 inlet feedwater nozzle to safe-end weld during the second refueling outage of River Bend Station Unit 1 in March 1989. The indication, approximately 15cm (6in) long with a reported maximum depth of 0.5cm (0.1in), was located in the Alloy 182 weld butter onmore » the safe-end side of the weld. (The safe-end base metal was ASME SA 508 Class 1 carbon steel.) The reported characteristics of the UT indication were indicative of intergranular stress corrosion cracking. This indication was reexamined during the second and third fuel cycles in March 1990 and September 1991, respectively, and during the third refuel outage in November 1990. Crack growth was reported during each examination. The safe-end was replaced during the fourth refueling outage in the summer of 1992. The US Nuclear Regulatory Commission (NRC) subsequently contracted with Brookhaven National laboratory (BNL) to conduct a confirmatory investigation to establish the failure mode and determine the root causes of cracking in the safe-end weld.« less

  20. 7 CFR 331.14 - Incident response. 6

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; bomb threats and suspicious packages; and emergencies such as fire, gas leak, explosion, power outage... information systems); severe weather and other natural disasters; workplace violence; bomb threats and...

  1. Protective Controller against Cascade Outages with Selective Harmonic Compensation Function

    NASA Astrophysics Data System (ADS)

    Abramovich, B. N.; Kuznetsov, P. A.; Sychev, Yu A.

    2018-05-01

    The paper presents data on the power quality and development of protective devices for the power networks with distributed generation (DG).The research has shown that power quality requirements for DG networks differ from conventional ones. That is why main tendencies, protective equipment and filters should be modified. There isa developed algorithm for detection and prevention of cascade outages that can lead to the blackoutin DG networks and there was a proposed structural scheme for a new active power filter for selective harmonics compensation. Analysis of these theories and equipment led to the development of protective device that could monitor power balance and cut off non-important consumers. The last part of the article describes a microcontroller prototype developed for connection to the existing power station control center.

  2. Concepts for 18/30 GHz satellite communication system study. Executive summary

    NASA Technical Reports Server (NTRS)

    Baker, M.; Davies, R.; Cuccia, L.; Mitchell, C.

    1979-01-01

    An examination of a multiplicity of interconnected parameters ranging from specific technology details to total system economic costs for satellite communication systems at the 18/30 GHz transmission bands are presented. It was determined that K sub A band systems can incur a small communications outage during very heavy rainfall periods and that reducing the outage to zero would lead to prohibitive system costs. On the other hand, the economics of scale, ie, one spacecraft accommodating 2.5 GHz of bandwidth coupled with multiple beam frequency reuse, leads to very low costs for those users who can tolerate the 5 to 50 hours per year of downtime. A multiple frequency band satellite network can provide the ultimate optimized match to the consumer performance/economics demands.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The report provides highlights related to impacts of Hurricane Frances and Hurricane Ivan in the Florida area. Sections on electric information, oil and gas information, county outage data, and a table for restoration targets/status are provided.

  4. Insights into Spring 2008 Gasoline Prices

    EIA Publications

    2008-01-01

    Gasoline prices rose rapidly in spring 2007 due a variety of factors, including refinery outages and lower than expected imports. This report explores those factors and looks at the implications for 2008.

  5. Improving Distribution Resiliency with Microgrids and State and Parameter Estimation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuffner, Francis K.; Williams, Tess L.; Schneider, Kevin P.

    Modern society relies on low-cost reliable electrical power, both to maintain industry, as well as provide basic social services to the populace. When major disturbances occur, such as Hurricane Katrina or Hurricane Sandy, the nation’s electrical infrastructure can experience significant outages. To help prevent the spread of these outages, as well as facilitating faster restoration after an outage, various aspects of improving the resiliency of the power system are needed. Two such approaches are breaking the system into smaller microgrid sections, and to have improved insight into the operations to detect failures or mis-operations before they become critical. Breaking themore » system into smaller sections of microgrid islands, power can be maintained in smaller areas where distribution generation and energy storage resources are still available, but bulk power generation is no longer connected. Additionally, microgrid systems can maintain service to local pockets of customers when there has been extensive damage to the local distribution system. However, microgrids are grid connected a majority of the time and implementing and operating a microgrid is much different than when islanded. This report discusses work conducted by the Pacific Northwest National Laboratory that developed improvements for simulation tools to capture the characteristics of microgrids and how they can be used to develop new operational strategies. These operational strategies reduce the cost of microgrid operation and increase the reliability and resilience of the nation’s electricity infrastructure. In addition to the ability to break the system into microgrids, improved observability into the state of the distribution grid can make the power system more resilient. State estimation on the transmission system already provides great insight into grid operations and detecting abnormal conditions by leveraging existing measurements. These transmission-level approaches are expanded to using advanced metering infrastructure and other distribution-level measurements to create a three-phase, unbalanced distribution state estimation approach. With distribution-level state estimation, the grid can be operated more efficiently, and outages or equipment failures can be caught faster, improving the overall resilience and reliability of the grid.« less

  6. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  7. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  8. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  9. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  10. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  11. Managing Critical Infrastructures C.I.M. Suite

    ScienceCinema

    Dudenhoeffer, Donald

    2018-05-23

    See how a new software package developed by INL researchers could help protect infrastructure during natural disasters, terrorist attacks and electrical outages. For more information about INL research, visit http://www.facebook.com/idahonationallaboratory.

  12. 75 FR 57006 - Addressing Policy and Logistical Challenges to Smart Grid Implementation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-17

    ... electric vehicles, photovoltaic cells, wind turbines, or inflexible nuclear plants? What approaches make... generation and electric vehicles into the electric system; detect and address equipment problems and outages...

  13. 49 CFR 173.24 - General requirements for packagings and packages.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) New packagings and packagings which are reused; and (3) Specification and non-specification packagings..., sufficient ullage (outage) must be left to ensure that neither leakage nor permanent distortion of the...

  14. Lightning-generated whistler waves observed by probes on the Communication/Navigation Outage Forecast System satellite at low latitudes

    NASA Astrophysics Data System (ADS)

    Holzworth, R. H.; McCarthy, M. P.; Pfaff, R. F.; Jacobson, A. R.; Willcockson, W. L.; Rowland, D. E.

    2011-06-01

    Direct evidence is presented for a causal relationship between lightning and strong electric field transients inside equatorial ionospheric density depletions. In fact, these whistler mode plasma waves may be the dominant electric field signal within such depletions. Optical lightning data from the Communication/Navigation Outage Forecast System (C/NOFS) satellite and global lightning location information from the World Wide Lightning Location Network are presented as independent verification that these electric field transients are caused by lightning. The electric field instrument on C/NOFS routinely measures lightning-related electric field wave packets or sferics, associated with simultaneous measurements of optical flashes at all altitudes encountered by the satellite (401-867 km). Lightning-generated whistler waves have abundant access to the topside ionosphere, even close to the magnetic equator.

  15. Lightning-Generated Whistler Waves Observed by Probes On The Communication/Navigation Outage Forecast System Satellite at Low Latitudes

    NASA Technical Reports Server (NTRS)

    Holzworth, R. H.; McCarthy, M. P.; Pfaff, R. F.; Jacobson, A. R.; Willcockson, W. L.; Rowland, D. E.

    2011-01-01

    Direct evidence is presented for a causal relationship between lightning and strong electric field transients inside equatorial ionospheric density depletions. In fact, these whistler mode plasma waves may be the dominant electric field signal within such depletions. Optical lightning data from the Communication/Navigation Outage Forecast System (C/NOFS) satellite and global lightning location information from the World Wide Lightning Location Network are presented as independent verification that these electric field transients are caused by lightning. The electric field instrument on C/NOFS routinely measures lightning ]related electric field wave packets or sferics, associated with simultaneous measurements of optical flashes at all altitudes encountered by the satellite (401.867 km). Lightning ]generated whistler waves have abundant access to the topside ionosphere, even close to the magnetic equator.

  16. Power System Reliability Assessment by Analysing Voltage Dips on the Blue Horizon Bay 22KV Overhead Line in the Nelson Mandela Bay Municipality

    NASA Astrophysics Data System (ADS)

    Lamour, B. G.; Harris, R. T.; Roberts, A. G.

    2010-06-01

    Power system reliability problems are very difficult to solve because the power systems are complex and geographically widely distributed and influenced by numerous unexpected events. It is therefore imperative to employ the most efficient optimization methods in solving the problems relating to reliability of the power system. This paper presents a reliability analysis and study of the power interruptions resulting from severe power outages in the Nelson Mandela Bay Municipality (NMBM), South Africa and includes an overview of the important factors influencing reliability, and methods to improve the reliability. The Blue Horizon Bay 22 kV overhead line, supplying a 6.6 kV residential sector has been selected. It has been established that 70% of the outages, recorded at the source, originate on this feeder.

  17. Simulating economic effects of disruptions in the telecommunications infrastructure.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Roger Gary; Barton, Dianne Catherine; Reinert, Rhonda K.

    2004-01-01

    CommAspen is a new agent-based model for simulating the interdependent effects of market decisions and disruptions in the telecommunications infrastructure on other critical infrastructures in the U.S. economy such as banking and finance, and electric power. CommAspen extends and modifies the capabilities of Aspen-EE, an agent-based model previously developed by Sandia National Laboratories to analyze the interdependencies between the electric power system and other critical infrastructures. CommAspen has been tested on a series of scenarios in which the communications network has been disrupted, due to congestion and outages. Analysis of the scenario results indicates that communications networks simulated by themore » model behave as their counterparts do in the real world. Results also show that the model could be used to analyze the economic impact of communications congestion and outages.« less

  18. Spot market runup over; buyers anticipate soft summer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, G.D.L.

    Spot methanol markets spiked to 38 cts/gal late last month as a result of planned and unplanned outages. Gulf Coast markets have already retreated from those highs, however, as traders and consumers anticipate more plentiful supply and lower prices by midsummer. May postings are likely to roll over at April levels of 37 cts-39 cts/gal, and late April notices that producers would no longer honor off-list discounts are being disregarded. The trigger for the price runup was a production snag a week before the recent fire at Hoechst Celanese`s Clear Lake, TX acetic acid plant. The company reports methanol ismore » back on-line. In addition, Cytec`s Fortier, LA methanol plant is in a two-month turnaround, and Texaco`s Delaware City, DE plant has been shut. Methanex (Vancouver) was taking output from those two units and was said to be in the spot market along with Hoechst Celanese`s partner, Valero, which exacerbated the spike. Lyondell is just restarting methanol after a maintenance outage. Although Texaco says the Delaware City plant is off-line for six months, market watchers do not expect it to restart soon, based on its cost structure at current prices. Quantum was planning a two-month maintenance and expansion project at its Deer Park, TX methanol and acetic acid plant, but in light of the Hoechst Celanese acetic outage Quantum may delay that project. Midyear is the startup target for the new BP Sterling plant at Texas City, TX.« less

  19. A fouling monitor alarm to prevent forced outages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, R.E.; Hickinbotham, A.; Fang, T.C.

    2000-07-01

    Many utilities rely on coal blending to meet emissions and boiler performance goals, but the increased variability in coal quality can adversely impact ash deposition and soot blowing requirements. Other utilities are experimenting with lower quality coals and burner zone blending of coals fired from different bunkers as part of a deregulation strategy to reduce fuel costs. However, these strategies can lead to slagging/fouling episodes, a possible outage, or a decrease in unit availability if boiler operations are not carefully monitored. This paper summarizes the development of software to monitor boiler fouling and to provide an advanced warning to themore » control operators when a fouling episode is imminent. With adequate warming, preemptive action can be taken (e.g., soot blowing, a change in coal blend, etc.) to potentially avoid a costly outage. The software utilizes a unique combination of combustion diagnostic techniques and convective section heat adsorption analyses to identify boiler operating conditions where ash deposition rates may be high and conductive to triggering a fouling episode. The paper outlines the history of the fouling problem and the implementation of the software on Wabamun Unit 4, a tangentially-fired unit with relatively narrow reheat tube spacing. The unit had a tendency to foul when burning a high alkaline (but low ash) coal seam. The paper discusses the software development, implementation, and data acquisitions activities. Preliminary test results are provided for Wabamun 4 and for Sundance Units 1 and 2 where the software was recently installed.« less

  20. 76 FR 56429 - Sunshine Act Meeting Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-13

    ..., Reliability, Security and Market Operations. A-3 OMITTED A-4 AD11-9-000 Report on Outages and Curtailments... is available through http://www.ferc.gov . Anyone with Internet access who desires to view this event...

  1. NREL Validates Go Electric's Technology As Part of Wells Fargo IN2

    Science.gov Websites

    solution: providing blip-less uninterruptible power; maintaining photovoltaics systems from tripping after renewables into an energy resiliency solution and keep them operating during a grid outage." Go Electric

  2. 75 FR 8044 - Summer Undergraduate Research Program Extension of Due Date for Proposals

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ...: Due to extreme weather conditions in the Mid-Atlantic United States, NIST is extending the deadline.... Eastern Time, Tuesday, February 16, 2010. Due to extreme weather conditions and associated power outages...

  3. An Optimized Handover Scheme with Movement Trend Awareness for Body Sensor Networks

    PubMed Central

    Sun, Wen; Zhang, Zhiqiang; Ji, Lianying; Wong, Wai-Choong

    2013-01-01

    When a body sensor network (BSN) that is linked to the backbone via a wireless network interface moves from one coverage zone to another, a handover is required to maintain network connectivity. This paper presents an optimized handover scheme with movement trend awareness for BSNs. The proposed scheme predicts the future position of a BSN user using the movement trend extracted from the historical position, and adjusts the handover decision accordingly. Handover initiation time is optimized when the unnecessary handover rate is estimated to meet the requirement and the outage probability is minimized. The proposed handover scheme is simulated in a BSN deployment area in a hospital environment in UK. Simulation results show that the proposed scheme reduces the outage probability by 22% as compared with the existing hysteresis-based handover scheme under the constraint of acceptable handover rate. PMID:23736852

  4. Quantifying and Monetizing Renewable Energy Resiliency

    DOE PAGES

    Anderson, Kate H.; Laws, Nicholas D.; Marr, Spencer; ...

    2018-03-23

    Energy resiliency has been thrust to the forefront by recent severe weather events and natural disasters. Billions of dollars are lost each year due to power outages. This article highlights the unique value renewable energy hybrid systems (REHS), comprised of solar, energy storage, and generators, provide in increasing resiliency. We present a methodology to quantify the amount and value of resiliency provided by REHS, and ways to monetize this resiliency value through insurance premium discounts. A case study of buildings in New York City demonstrates how implementing REHS in place of traditional backup diesel generators can double the amount ofmore » outage survivability, with an added value of $781,200. For a Superstorm Sandy type event, results indicate that insurance premium reductions could support up to 4% of the capital cost of REHS, and the potential exists to prevent up to $2.5 billion in business interruption losses with increased REHS deployment.« less

  5. The Fixed-bias Langmuir Probe on the Communication-navigation Outage Forecast System Satellite: Calibration and Validation

    NASA Technical Reports Server (NTRS)

    Klenzing, Jeffrey H.; Rowland, Douglas E.

    2012-01-01

    A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasmadensity is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future xed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.

  6. Quantifying and Monetizing Renewable Energy Resiliency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Kate H.; Laws, Nicholas D.; Marr, Spencer

    Energy resiliency has been thrust to the forefront by recent severe weather events and natural disasters. Billions of dollars are lost each year due to power outages. This article highlights the unique value renewable energy hybrid systems (REHS), comprised of solar, energy storage, and generators, provide in increasing resiliency. We present a methodology to quantify the amount and value of resiliency provided by REHS, and ways to monetize this resiliency value through insurance premium discounts. A case study of buildings in New York City demonstrates how implementing REHS in place of traditional backup diesel generators can double the amount ofmore » outage survivability, with an added value of $781,200. For a Superstorm Sandy type event, results indicate that insurance premium reductions could support up to 4% of the capital cost of REHS, and the potential exists to prevent up to $2.5 billion in business interruption losses with increased REHS deployment.« less

  7. Performance of multi-hop parallel free-space optical communication over gamma-gamma fading channel with pointing errors.

    PubMed

    Gao, Zhengguang; Liu, Hongzhan; Ma, Xiaoping; Lu, Wei

    2016-11-10

    Multi-hop parallel relaying is considered in a free-space optical (FSO) communication system deploying binary phase-shift keying (BPSK) modulation under the combined effects of a gamma-gamma (GG) distribution and misalignment fading. Based on the best path selection criterion, the cumulative distribution function (CDF) of this cooperative random variable is derived. Then the performance of this optical mesh network is analyzed in detail. A Monte Carlo simulation is also conducted to demonstrate the effectiveness of the results for the average bit error rate (ABER) and outage probability. The numerical result proves that it needs a smaller average transmitted optical power to achieve the same ABER and outage probability when using the multi-hop parallel network in FSO links. Furthermore, the system use of more number of hops and cooperative paths can improve the quality of the communication.

  8. A dynamic programming approach to estimate the capacity value of energy storage

    DOE PAGES

    Sioshansi, Ramteen; Madaeni, Seyed Hossein; Denholm, Paul

    2013-09-17

    Here, we present a method to estimate the capacity value of storage. Our method uses a dynamic program to model the effect of power system outages on the operation and state of charge of storage in subsequent periods. We combine the optimized dispatch from the dynamic program with estimated system loss of load probabilities to compute a probability distribution for the state of charge of storage in each period. This probability distribution can be used as a forced outage rate for storage in standard reliability-based capacity value estimation methods. Our proposed method has the advantage over existing approximations that itmore » explicitly captures the effect of system shortage events on the state of charge of storage in subsequent periods. We also use a numerical case study, based on five utility systems in the U.S., to demonstrate our technique and compare it to existing approximation methods.« less

  9. Scale models: A proven cost-effective tool for outage planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, R.; Segroves, R.

    1995-03-01

    As generation costs for operating nuclear stations have risen, more nuclear utilities have initiated efforts to improve cost effectiveness. Nuclear plant owners are also being challenged with lower radiation exposure limits and new revised radiation protection related regulations (10 CFR 20), which places further stress on their budgets. As source term reduction activities continue to lower radiation fields, reducing the amount of time spent in radiation fields becomes one of the most cost-effective ways of reducing radiation exposure. An effective approach for minimizing time spent in radiation areas is to use a physical scale model for worker orientation planning andmore » monitoring maintenance, modifications, and outage activities. To meet the challenge of continued reduction in the annual cumulative radiation exposures, new cost-effective tools are required. One field-tested and proven tool is the physical scale model.« less

  10. Economic impacts of the ShakeOut scenario

    USGS Publications Warehouse

    Rose, A.; Wei, D.; Wein, A.

    2011-01-01

    For the ShakeOut Earthquake Scenario, we estimate $68 billion in direct and indirect business interruption (BI) and $11 billion in related costs in addition to the $113 billion in property damage in an eight-county Southern California region. The modeled conduits of shock to the economy are property damage and lifeline service outages that affect the economy’s ability to produce. Property damage from fire is 50% greater than property damage from shaking because fire is more devastating. BI from water service disruption and fire each represent around one-third of total BI losses because of the long duration of service outage or long restoration and reconstruction periods. Total BI losses are 4.3% of annual gross output in the affected region, an impact far larger than most conventional economic recessions. These losses are still much lower than they potentially could be due to the resilience of the economy.

  11. Interference Information Based Power Control for Cognitive Radio with Multi-Hop Cooperative Sensing

    NASA Astrophysics Data System (ADS)

    Yu, Youngjin; Murata, Hidekazu; Yamamoto, Koji; Yoshida, Susumu

    Reliable detection of other radio systems is crucial for systems that share the same frequency band. In wireless communication channels, there is uncertainty in the received signal level due to multipath fading and shadowing. Cooperative sensing techniques in which radio stations share their sensing information can improve the detection probability of other systems. In this paper, a new cooperative sensing scheme that reduces the false detection probability while maintaining the outage probability of other systems is investigated. In the proposed system, sensing information is collected using multi-hop transmission from all sensing stations that detect other systems, and transmission decisions are based on the received sensing information. The proposed system also controls the transmit power based on the received CINRs from the sensing stations. Simulation results reveal that the proposed system can reduce the outage probability of other systems, or improve its link success probability.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Severe wind and snow storms hit the Pacific Northwest region on December 14 – 15, 2006, following severe flooding during the past few days. The severe weather resulted in major power outages through the region. At peak there were 1.8 million customers without power which included BC Hydro in Canada. Currently, there are over 1.5 million outages in the region as a result of the Pacific Northwest Storms. This represents about 42 percent of customers in affected utility service areas in Oregon and Washington. See table below. Because the current wind and snow storms are coming on the heels ofmore » extensive flooding in the region, electric utilities are experiencing damage. Wind gusts reached close to 100 mph in some areas of the region. The storm is expected to bring its strong winds and heavy snow into Idaho, Montana and Wyoming Friday and into the weekend. There are currently no reported major impacts to the petroleum and natural gas infrastructure.« less

  13. Performance analysis of OOK-based FSO systems in Gamma-Gamma turbulence with imprecise channel models

    NASA Astrophysics Data System (ADS)

    Feng, Jianfeng; Zhao, Xiaohui

    2017-11-01

    For an FSO communication system with imprecise channel model, we investigate its system performance based on outage probability, average BEP and ergodic capacity. The exact FSO links are modeled as Gamma-Gamma fading channel in consideration of both atmospheric turbulence and pointing errors, and the imprecise channel model is treated as the superposition of exact channel gain and a Gaussian random variable. After we derive the PDF, CDF and nth moment of the imprecise channel gain, and based on these statistics the expressions for the outage probability, the average BEP and the ergodic capacity in terms of the Meijer's G functions are obtained. Both numerical and analytical results are presented. The simulation results show that the communication performance deteriorates in the imprecise channel model, and approaches to the exact performance curves as the channel model becomes accurate.

  14. Performance analysis for mixed FSO/RF Nakagami-m and Exponentiated Weibull dual-hop airborne systems

    NASA Astrophysics Data System (ADS)

    Jing, Zhao; Shang-hong, Zhao; Wei-hu, Zhao; Ke-fan, Chen

    2017-06-01

    In this paper, the performances of mixed free-space optical (FSO)/radio frequency (RF) systems are presented based on the decode-and-forward relaying. The Exponentiated Weibull fading channel with pointing error effect is adopted for the atmospheric fluctuation of FSO channel and the RF link undergoes the Nakagami-m fading. We derived the analytical expression for cumulative distribution function (CDF) of equivalent signal-to-noise ratio (SNR). The novel mathematical presentations of outage probability and average bit-error-rate (BER) are developed based on the Meijer's G function. The analytical results show an accurately match to the Monte-Carlo simulation results. The outage and BER performance for the mixed system by decode-and-forward relay are investigated considering atmospheric turbulence and pointing error condition. The effect of aperture averaging is evaluated in all atmospheric turbulence conditions as well.

  15. Increasing Resiliency Through Renewable Energy Microgrids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Katherine H; DiOrio, Nicholas A; Cutler, Dylan S

    This paper describes a methodology to quantify the economic and resiliency benefit provided by renewable energy (RE) in a hybrid RE-storage-diesel microgrid. We present a case study to show how this methodology is applied to a multi-use/ multi-function telecommunications facility in southern California. In the case study, we first identify photovoltaic (PV) and battery energy storage system (BESS) technologies that minimize the lifecycle cost of energy at the site under normal, grid-connected operation. We then evaluate how those technologies could be incorporated alongside existing diesel generators in a microgrid to increase resiliency at the site, where resiliency is quantified inmore » terms of the amount of time that the microgrid can sustain the critical load during a grid outage. We find that adding PV and BESS to the existing backup diesel generators with a fixed fuel supply extends the amount of time the site could survive an outage by 1.8 days, from 1.7 days for the existing diesel-only backup system to 3.5 days for the PV/diesel/BESS hybrid system. Furthermore, even after diesel fuel supplies are exhausted, the site can continue to operate critical loads during daytime hours using just the PV/BESS when there is sufficient solar resource. We find that the site can save approximately $100,000 in energy costs over the 25-year lifecycle while doubling the amount of time they can survive an outage. The methodology presented here provides a template for increasing resiliency at telecomm sites by implementing renewable energy solutions, which provide additional benefits of carbon emission reduction and energy cost savings.« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Richard P.; Stamp, Jason E.; Eddy, John P.

    Many critical loads rely on simple backup generation to provide electricity in the event of a power outage. An Energy Surety Microgrid TM can protect against outages caused by single generator failures to improve reliability. An ESM will also provide a host of other benefits, including integration of renewable energy, fuel optimization, and maximizing the value of energy storage. The ESM concept includes a categorization for microgrid value proposi- tions, and quantifies how the investment can be justified during either grid-connected or utility outage conditions. In contrast with many approaches, the ESM approach explic- itly sets requirements based on unlikelymore » extreme conditions, including the need to protect against determined cyber adversaries. During the United States (US) Department of Defense (DOD)/Department of Energy (DOE) Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) effort, the ESM methodology was successfully used to develop the preliminary designs, which direct supported the contracting, construction, and testing for three military bases. Acknowledgements Sandia National Laboratories and the SPIDERS technical team would like to acknowledge the following for help in the project: * Mike Hightower, who has been the key driving force for Energy Surety Microgrids * Juan Torres and Abbas Akhil, who developed the concept of microgrids for military installations * Merrill Smith, U.S. Department of Energy SPIDERS Program Manager * Ross Roley and Rich Trundy from U.S. Pacific Command * Bill Waugaman and Bill Beary from U.S. Northern Command * Melanie Johnson and Harold Sanborn of the U.S. Army Corps of Engineers Construc- tion Engineering Research Laboratory * Experts from the National Renewable Energy Laboratory, Idaho National Laboratory, Oak Ridge National Laboratory, and Pacific Northwest National Laboratory« less

  17. Critical Assessment of the Foundations of Power Transmission and Distribution Reliability Metrics and Standards.

    PubMed

    Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan

    2016-01-01

    The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.

  18. Energy Efficiency Maximization for WSNs with Simultaneous Wireless Information and Power Transfer

    PubMed Central

    Yu, Hongyan; Zhang, Yongqiang; Yang, Yuanyuan; Ji, Luyue

    2017-01-01

    Recently, the simultaneous wireless information and power transfer (SWIPT) technique has been regarded as a promising approach to enhance performance of wireless sensor networks with limited energy supply. However, from a green communication perspective, energy efficiency optimization for SWIPT system design has not been investigated in Wireless Rechargeable Sensor Networks (WRSNs). In this paper, we consider the tradeoffs between energy efficiency and three factors including spectral efficiency, the transmit power and outage target rate for two different modes, i.e., power splitting (PS) and time switching modes (TS), at the receiver. Moreover, we formulate the energy efficiency maximization problem subject to the constraints of minimum Quality of Service (QoS), minimum harvested energy and maximum transmission power as non-convex optimization problem. In particular, we focus on optimizing power control and power allocation policy in PS and TS modes to maximize energy efficiency of data transmission. For PS and TS modes, we propose the corresponding algorithm to characterize a non-convex optimization problem that takes into account the circuit power consumption and the harvested energy. By exploiting nonlinear fractional programming and Lagrangian dual decomposition, we propose suboptimal iterative algorithms to obtain the solutions of non-convex optimization problems. Furthermore, we derive the outage probability and effective throughput from the scenarios that the transmitter does not or partially know the channel state information (CSI) of the receiver. Simulation results illustrate that the proposed optimal iterative algorithm can achieve optimal solutions within a small number of iterations and various tradeoffs between energy efficiency and spectral efficiency, transmit power and outage target rate, respectively. PMID:28820496

  19. Energy Efficiency Maximization for WSNs with Simultaneous Wireless Information and Power Transfer.

    PubMed

    Yu, Hongyan; Zhang, Yongqiang; Guo, Songtao; Yang, Yuanyuan; Ji, Luyue

    2017-08-18

    Recently, the simultaneous wireless information and power transfer (SWIPT) technique has been regarded as a promising approach to enhance performance of wireless sensor networks with limited energy supply. However, from a green communication perspective, energy efficiency optimization for SWIPT system design has not been investigated in Wireless Rechargeable Sensor Networks (WRSNs). In this paper, we consider the tradeoffs between energy efficiency and three factors including spectral efficiency, the transmit power and outage target rate for two different modes, i.e., power splitting (PS) and time switching modes (TS), at the receiver. Moreover, we formulate the energy efficiency maximization problem subject to the constraints of minimum Quality of Service (QoS), minimum harvested energy and maximum transmission power as non-convex optimization problem. In particular, we focus on optimizing power control and power allocation policy in PS and TS modes to maximize energy efficiency of data transmission. For PS and TS modes, we propose the corresponding algorithm to characterize a non-convex optimization problem that takes into account the circuit power consumption and the harvested energy. By exploiting nonlinear fractional programming and Lagrangian dual decomposition, we propose suboptimal iterative algorithms to obtain the solutions of non-convex optimization problems. Furthermore, we derive the outage probability and effective throughput from the scenarios that the transmitter does not or partially know the channel state information (CSI) of the receiver. Simulation results illustrate that the proposed optimal iterative algorithm can achieve optimal solutions within a small number of iterations and various tradeoffs between energy efficiency and spectral efficiency, transmit power and outage target rate, respectively.

  20. 75 FR 8153 - Nebraska Public Power District; Cooper Nuclear Station Environmental Assessment and Finding of No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... of the fall 2009 refueling outage and other factors, including inclement weather. Environmental... Management System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Web site, http://www.nrc...

  1. 76 FR 7592 - Entergy Nuclear Vermont Yankee, LLC and Entergy Nuclear Operations, Inc.; Notice of Issuance of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-10

    ... completed to the Commission's satisfaction: (1) The tritiated groundwater remediation process; (2) the soil remediation process scheduled to take place during the refueling outage, to remove soil containing tritium and...

  2. ASDC Tools Temporarily Unavailable

    Atmospheric Science Data Center

    2015-12-21

    ... The ASDC will be conducting maintenance due to an unexpected power outage. The Data Pool, MISR order and browse tools, TAD, TES and ... may be unavailable during maintenance. Data processing and distribution may be impacted and systems are expected to return to normal ...

  3. NOAA Weather Radio - Outage Reporting

    Science.gov Websites

    SAME Programación en Español NOAA Social Media NOAA Youtube NOAA's Facebook NOAA Twitter Feed NWS Youtube NWS Facebook NWS Twitter Feed USA.GOV Image US Dept of Commerce National Oceanic and Atmospheric

  4. Guidelines for traffic signal energy back\\0x2010up systems : final report.

    DOT National Transportation Integrated Search

    2009-07-01

    Power outages affect traffic signalized intersections, leading to potentially serious problems. Current practices of responding to power failures are very basic, ranging from do nothing to installing portable generators. The purpose of this res...

  5. 75 FR 9955 - Entergy Operations, Inc.; Grand Gulf Nuclear Station, Unit 1; Environmental Assessment and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-04

    ... outage and other factors, such as limited vendor resources. Environmental Impacts of the Proposed Action... System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Web site, http://www.nrc.gov...

  6. Chemical Safety Alert: Chemical Accidents from Electric Power Outages

    EPA Pesticide Factsheets

    Incident data from the National Response Center (NRC) shows that during 2000 there were about 240 chemical releases reported due to an electric power interruption, as well as resumption/restart; only a few were related to planned rolling blackouts.

  7. Creating Productive Roadways : Developing an Advanced Energy Production, Storage, and Distribution System

    DOT National Transportation Integrated Search

    2013-05-01

    Renewable electric power production could reduce highway maintenance and operating costs and provide backup for critical systems during power outages. Using the public right-of-way and roadway infrastructure as a source for energy production, storage...

  8. 76 FR 31381 - Office Of New Reactors; Proposed Revision 4 to Standard Review Plan; Section 8.1 on Electric...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-31

    ...). The current revision issues a new Branch Technical Position (BTP) 8-8 on ``Onsite (Emergency Diesel Generators) and Offsite Power Sources Allowed Outage Time Extensions.'' (ADAMS Accession No. ML111180521...

  9. A Business Case for Nuclear Plant Control Room Modernization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, Ken; Lawrie, Sean; Niedermuller, Josef M.

    This paper presents a generic business case for implementation of technology that supports Control Room Modernization (CRM). The analysis presented in two forms; 1) a standalone technology upgrade, and 2) a technology upgrade that is built upon and incremental to a prior business case created for Mobile Work Packages (MWP). The business case contends that advanced communication and networking and analytical technologies will allow NPP to conduct control room operations with improved focus by reducing human factors and redundant manpower, and therefore operate with fewer errors. While some labor savings can be harvested in terms of overtime, the majority ofmore » savings are demonstrated as reduced time to take the plant off line and bring back on line in support of outages. The benefits are quantified to a rough order of magnitude that provides directional guidance to NPPs that are interested in developing a similar business case. This business case focuses on modernization of the operator control room and does not consider a complete overhaul and modernization of a plants instrument and control systems. While operators may be considering such an investment at their plants, the sizable capital investment required is not likely supported by a cost/benefit analysis alone. More likely, it is driven by obsolescence and reliability issues, and requires consideration of mechanical condition of plant systems, capital depreciation, financing, relicensing and overall viability of the plant asset over a 20-year horizon in a competitive market. Prior studies [REF] have indicated that such a modernization of plant I&C systems, alone or as part of a larger modernization effort, can yield very significant reductions in O&M costs. However, the depth of research and analysis required to develop a meaningful business case for a plant modernization effort is well beyond the scope of this study. While CRM as considered in this study can be easily integrated as part of grander plant modernization effort, it can also be considered as a stand-alone project, implemented as a supervisorial layer over and above existing systems. CRM is enabled by a suite of technologies, which are described in further detail in the body of this report. They include: • Modernized control room with interactive displays • High-bandwidth wireless networks • Mobile devices • Component identification technology • Mobile wireless video cameras • Smart or task based operator displays • Computer-Based Procedures (CBP)/Automated Mobile Work Packages (MWP) • Intelligent plant configuration • Advanced data analytics An analysis was conducted to determine how these technologies might impact outage operations at an NPP. The analysis concluded that outage management capabilities would be improved with application of these technologies, and result in annual benefits for the plant. These improved capabilities were identified and described in further detail in this report. • Reduction in need redundant manpower (verification, etc) • Improved critical path shutdown and restart duration during outages • Reduction in human factors and errors • Remote watches • Paperless outage coordination • Bulk work optimization« less

  10. GPS aviation outage prediction and reporting systems

    DOT National Transportation Integrated Search

    1997-11-01

    Use of GPS for instrument flight rule (IFR) air navigation requires that the system have integrity. Integrity is the ability to detect when a satellite is out of tolerance and should not be used in the navigation solution and then warns the pilot in ...

  11. Maintenance Downtime August 22, 23, 29, 30, 2014

    Atmospheric Science Data Center

    2014-08-28

    ... Friday, August 22, 2014 to Saturday, August 23, 2014 Time:  07:00 pm - 08:00 am EDT Event ... on Friday evening through Saturday morning on Aug. 22-23, and again on Aug. 29-30. Periods of intermittent network outages will occur ...

  12. Keep Food and Water Safe After a Disaster or Power Outage

    MedlinePlus

    ... DO NOT drink the water. Use a safe water supply like bottled or treated water. Contact your local, ... you know the water is safe, use bottled water or some other safe supply of water. If you suspect your water has ...

  13. 77 FR 20018 - Combined Notice of Filings #2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-03

    ...-5133. Comments Due: 5 p.m. ET 4/13/12. Docket Numbers: ER12-1095-001. Applicants: PJM Interconnection... incorporating TOA Sec 4.8.4 re Direct Billing to Late Outages--ER12-1095 to be effective 4/16/2012. Filed Date...

  14. NERSC News

    Science.gov Websites

    Performance Data, Analytics & Services Job Logs & Statistics Training & Tutorials Software Outages NERSC Training Spectrum Scale User Group Meeting Live Status Now Computing Queue Look MOTD » Deep Learning at 15 PFlops Enables Training for Extreme Weather Identification at Scale March 29, 2018

  15. Human factors in airway facilities maintenance : development of a prototype outage assessment inventory.

    DOT National Transportation Integrated Search

    1994-02-01

    The airway facilities (AF) maintenance community is concerned with identifying ways of reducing both the incidence of equipment failure and the amount of time required to restore equipment to operational status following a failure. It is vitally impo...

  16. SCALE-MODEL STUDIES OF MIXING IN DRINKING WATER STORAGE TANKS

    EPA Science Inventory

    Storage tanks and reservoirs are commonly used in drinking water distribution systems to equalize pumping requirements and operating pressures, and to provide emergency water for fire-fighting and pumping outages. Poor mixing in these structures can create pockets of older water...

  17. Fuel Cells for Backup Power in Telecommunications Facilities (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2009-04-01

    Telecommunications providers rely on backup power to maintain a constant power supply, to prevent power outages, and to ensure the operability of cell towers, equipment, and networks. The backup power supply that best meets these objectives is fuel cell technology.

  18. Maintenance Downtime May 8 - 11, 2015

    Atmospheric Science Data Center

    2015-05-06

    ... The ASDC will experience a partial outage to move from old storage to new storage. ANGe ingest will be paused and production processing on ... any inconvenience this may cause.   The following data providers will be impacted: AFWA-MESH16 CloudSat FLASH GHRC NCEP ...

  19. Improving Energy Security for Air Force Installations

    NASA Astrophysics Data System (ADS)

    Schill, David

    Like civilian infrastructure, Air Force installations are dependent on electrical energy for daily operations. Energy shortages translate to decreased productivity, higher costs, and increased health risks. But for the United States military, energy shortages have the potential to become national security risks. Over ninety-five percent of the electrical energy used by the Air Force is supplied by the domestic grid, which is susceptible to shortages and disruptions. Many Air Force operations require a continuous source of energy, and while the Air Force has historically established redundant supplies of electrical energy, these back-ups are designed for short-term outages and may not provide sufficient supply for a longer, sustained power outage. Furthermore, it is the goal of the Department of Defense to produce or procure 25 percent of its facility energy from renewable sources by fiscal year 2025. In a government budget environment where decision makers are required to provide more capability with less money, it is becoming increasingly important for informed decisions regarding which energy supply options bear the most benefit for an installation. The analysis begins by exploring the field of energy supply options available to an Air Force installation. The supply options are assessed according to their ability to provide continuous and reliable energy, their applicability to unique requirements of Air Force installations, and their costs. Various methods of calculating energy usage by an installation are also addressed. The next step of this research develops a methodology and tool which assesses how an installation responds to various power outage scenarios. Lastly, various energy supply options are applied to the tool, and the results are reported in terms of cost and loss of installation capability. This approach will allow installation commanders and energy managers the ability to evaluate the cost and effectiveness of various energy investment options.

  20. New York Solar Smart DG Hub-Resilient Solar Project: Economic and Resiliency Impact of PV and Storage on New York Critical Infrastructure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Kate; Burman, Kari; Simpkins, Travis

    Resilient PV, which is solar paired with storage ('solar-plus-storage'), provides value both during normal grid operation and power outages as opposed to traditional solar PV, which functions only when the electric grid is operating. During normal grid operations, resilient PV systems help host sites generate revenue and/or reduce electricity bill charges. During grid outages, resilient PV provides critical emergency power that can help people in need and ease demand on emergency fuel supplies. The combination of grid interruptions during recent storms, the proliferation of solar PV, and the growing deployment of battery storage technologies has generated significant interest in usingmore » these assets for both economic and resiliency benefits. This report analyzes the technical and economic viability for resilient PV on three critical infrastructure sites in New York City (NYC): a school that is part of a coastal storm shelter system, a fire station, and a NYCHA senior center that serves as a cooling center during heat emergencies. This analysis differs from previous solar-plus-storage studies by placing a monetary value on resiliency and thus, in essence, modeling a new revenue stream for the avoided cost of a power outage. Analysis results show that resilient PV is economically viable for NYC's critical infrastructure and that it may be similarly beneficial to other commercial buildings across the city. This report will help city building owners, managers, and policymakers better understand the economic and resiliency benefits of resilient PV. As NYC fortifies its building stock against future storms of increasing severity, resilient PV can play an important role in disaster response and recovery while also supporting city greenhouse gas emission reduction targets and relieving stress to the electric grid from growing power demands.« less

  1. GBAS GAST D availability analysis for business aircraft

    NASA Astrophysics Data System (ADS)

    Dvorska, J.; Lipp, A.; Podivin, L.; Duchet, D.

    This paper analyzes Initial GBAS GAST D availability at a set of current ILS CAT III airports. Eurocontrol Pegasus Availability Tool, designed for SESAR projects is used for the assessment. Overall availability of the GBAS GAST D system is considered, focusing on business aircraft specifics where applicable. Nominal as well as adverse scenarios are presented in order to determine whether GAST D can reach the required availability for business aircraft at CAT III airport locations and under which conditions. The availability target was set at 99.9% availability when considering satellite outages in a given constellation and 99.997% when no outages are included. Sensitivity simulations were run for different scenarios and impacts of geometry screening thresholds, scale heights, aircraft mask, ground mask, sigma pseudorange ground, sigma ionospheric gradient, simulated year and different approach point (decision height) were analyzed. Some were run for a limited set of ILS CAT III airports and most of them for an almost complete set of nominal airports. Business aircraft specific assumptions, as well as aircraft type independent parameters (constellations, satellite outages, etc.) are examined in the paper. Conclusion summarizes the overall outcome of the simulations, showing that Initial GBAS CAT II/III can provide sufficient availability for all or almost all ILS CAT III capable airports considered in this study; and under which conditions. Recommendations for parameters that can be influenced (e.g. antenna location) if necessary are provided. It can also be expected that the availability will increase with the increasing amount of GNSS satellites. The work shows how different parameters impact availability of initial GBAS GAST D service for business aircraft, and that sufficient availability of GAST D service can be expected at most airports.

  2. The Challenge of Fulfilling a Perplexing Space Weather User Requirement

    NASA Astrophysics Data System (ADS)

    Kunches, J. M.; Boteler, D.; Wang, H.

    2006-12-01

    To fly commercial aircraft over the poles, it is necessary to ensure that air-ground and air-air communications be maintained throughout the flight. Some U. S. carriers have requested a seven hour lead-time for predictions of HF outages, the primary communication means for flying over the pole. This very difficult-to-meet specification results from the necessity to make alternative fueling arrangements, schedule additional flight crews, modify the loading of the aircraft, etc., to minimize the costs due to redirecting aircraft away from the optimal polar route. To satisfy this stringent requirement, better predictions of solar energetic particle (SEPs) events are necessary. Even soft SEPs can cause HF outages lasting for hours. This requirement challenges the international science community to significantly improve current predictive methodologies. Presently, a 1-2 hour lead-time may be the longest that can be obtained with a reasonable false alarm rate. Globally, there are a number of new programs, organized under the auspices of the International Space Environment Service (ISES), to facilitate progress in meeting the airlines' requirement. The Regional Warning Center in Canada is implementing a network of riometers at high latitudes, so to detect ionospheric conditions that result in HF outages. This chain is now being deployed. The Regional Warning Centers in Russia, China, the United States and Japan are working with the Canadians, to acquire and make available, other real-time data relevant to the problem. These data include solar, interplanetary, geomagnetic and ionospheric data. Clearly this challenge spans the realm of space science, from the solar and galactic origins of energetic particles, to the D-Region of Earth's ionosphere. The presentation will lay out a roadmap for an iterative solution to the prediction challenge, and identify some of the key areas to be addressed.

  3. 75 FR 3943 - Southern Nuclear Operating Company, Inc.; Vogtle Electric Generating Plant, Units 1 and 2...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-25

    ... impacts, including the spring 2010 Unit 2 refueling outage and other factors. Environmental Impacts of the... Reading Room on the Internet at the NRC Web site: http://www.nrc.gov/reading-rm/adams.html . Persons who...

  4. 47 CFR 4.5 - Definitions of outage, special offices and facilities, and 911 special facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... affects at least 900,000 user-minutes; or (4) There is a loss of ANI/ALI (associated name and location... 30 minutes and potentially affecting at least 900,000 user-minutes (provided that the ANI/ALI or...

  5. Multiline radar scan

    NASA Technical Reports Server (NTRS)

    Levinson, S.

    1977-01-01

    Scanning scheme is more efficient than conventional scanning. Originally designed for optical radar in space vehicles, scheme may also find uses in site-surveillance security systems and in other industrial applications. It should be particularly useful when system must run on battery energy, as would be case in power outages.

  6. 75 FR 51041 - FIFRA Scientific Advisory Panel; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-18

    ... public process provided only for convenience. If difficulties arise resulting in webcasting outages, the... comment due to technical difficulties and cannot contact you for clarification, EPA may not be able to..., Office of Science Coordination and Policy (7201M), [[Page 51042

  7. 78 FR 48672 - FIFRA Scientific Advisory Panel; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-09

    ... for convenience. If difficulties arise resulting in webcasting outages, the meeting will continue as..., DFO, Office of Science Coordination and Policy (7201M), Environmental Protection Agency, 1200... the document by docket ID number and other identifying information (subject heading, Federal Register...

  8. Global Positioning System Disaster Notification Messaging Service

    DTIC Science & Technology

    2013-09-01

    under AT&T service. Differing combinations of phone operating system types and versions (Android, iOS, Windows 8, Blackberry OS, et al.) service...streets, tunnels and subways. Substantial damage was incurred along the Atlantic coasts of both states with sustained power outages. As the storm’s

  9. 14 CFR 171.323 - Fabrication and installation requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., using applicable electric and safety codes and Federal Communications Commission (FCC) licensing... time not to exceed 1.5 hours. This measure applies to correction of unscheduled failures of the monitor... measure applies to unscheduled outage, out-of-tolerance conditions, and failures of the monitor...

  10. 47 CFR 63.63 - Emergency discontinuance, reduction, or impairment of service.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... impairment of service. 63.63 Section 63.63 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED... AND IMPAIRMENT OF SERVICE BY COMMON CARRIERS; AND GRANTS OF RECOGNIZED PRIVATE OPERATING AGENCY STATUS Discontinuance, Reduction, Outage and Impairment § 63.63 Emergency discontinuance, reduction, or impairment of...

  11. 77 FR 3752 - Commission Information Collection Activities (FERC-725I); Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-25

    ... the Bulk-Power System to system disturbances, including scheduled and unscheduled outages; requires each reliability coordinator to establish requirements for its area's dynamic disturbance recording... Retention--10.... 10 acquisition and installation of dynamic disturbance recorders. GO, TO, and RC to...

  12. 77 FR 28595 - Sunshine Act Meeting Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-15

    ...-Southern California Outages on September 8, 2011. Electric E-1 RM10-23-001 Transmission Planning and Cost... Communications Trustees of the City of Muscatine, Iowa; Central Minnesota Municipal Power Agency; City of Columbia, Missouri, Water & Light Company; City Water, Light & Power (Springfield, Illinois); Dairyland...

  13. 75 FR 80391 - Electric Reliability Organization Interpretations of Interconnection Reliability Operations and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ... configuration to maintain system stability, acceptable voltage or power flows.\\12\\ \\12\\ In the Western... prevent system instability or cascading outages, and protect other facilities in response to transmission... nature used to address system reliability vulnerabilities to prevent system instability, cascading...

  14. The Fixed-Bias Langmuir Probe on the Communication-Navigation Outage Forecast System Satellite: Calibration and Validation

    NASA Technical Reports Server (NTRS)

    Klenzing, J.; Rowland, D.

    2012-01-01

    A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasma density is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future fixed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.

  15. Cache-enabled small cell networks: modeling and tradeoffs.

    PubMed

    Baştuǧ, Ejder; Bennis, Mehdi; Kountouris, Marios; Debbah, Mérouane

    We consider a network model where small base stations (SBSs) have caching capabilities as a means to alleviate the backhaul load and satisfy users' demand. The SBSs are stochastically distributed over the plane according to a Poisson point process (PPP) and serve their users either (i) by bringing the content from the Internet through a finite rate backhaul or (ii) by serving them from the local caches. We derive closed-form expressions for the outage probability and the average delivery rate as a function of the signal-to-interference-plus-noise ratio (SINR), SBS density, target file bitrate, storage size, file length, and file popularity. We then analyze the impact of key operating parameters on the system performance. It is shown that a certain outage probability can be achieved either by increasing the number of base stations or the total storage size. Our results and analysis provide key insights into the deployment of cache-enabled small cell networks (SCNs), which are seen as a promising solution for future heterogeneous cellular networks.

  16. Lightning protection of distribution systems

    NASA Astrophysics Data System (ADS)

    Darveniza, M.; Uman, M. A.

    1982-09-01

    Research work on the lightning protection of distribution systems is described. The rationale behind the planning of the first major phase of the work - the field experiments conducted in the Tampa Bay area during August 1978 and July to September 1979 is explained. The aims of the field work were to characterize lightning in the Tampa Bay area, and to identify the lightning parameters associated with the occurrence of line outages and equipment damage on the distribution systems of the participating utilities. The equipment developed for these studies is fully described. The field work provided: general data on lightning - e.g., electric and magnetic fields of cloud and ground flashes; data from automated monitoring of lightning activity; stroke current waveshapes and peak currents measured at distribution arresters; and line outage and equipment damage on 13 kV networks in the Tampa Bay area. Computer aided analyses were required to collate and to process the accumulated data. The computer programs developed for this work are described.

  17. Enhancing DSN Operations Efficiency with the Discrepancy Reporting Management System (DRMS)

    NASA Technical Reports Server (NTRS)

    Chatillon, Mark; Lin, James; Cooper, Tonja M.

    2003-01-01

    The DRMS is the Discrepancy Reporting Management System used by the Deep Space Network (DSN). It uses a web interface and is a management tool designed to track and manage: data outage incidents during spacecraft tracks against equipment and software known as DRs (discrepancy Reports), to record "out of pass" incident logs against equipment and software in a Station Log, to record instances where equipment has be restarted or reset as Reset records, and to electronically record equipment readiness status across the DSN. Tracking and managing these items increases DSN operational efficiency by providing: the ability to establish the operational history of equipment items, data on the quality of service provided to the DSN customers, the ability to measure service performance, early insight into processes, procedures and interfaces that may need updating or changing, and the capability to trace a data outage to a software or hardware change. The items listed above help the DSN to focus resources on areas of most need.

  18. DGs for Service Restoration to Critical Loads in a Secondary Network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Yin; Liu, Chen-Ching; Wang, Zhiwen

    During a major outage in a secondary network distribution system, distributed generators (DGs) connected to the primary feeders as well as the secondary network can be used to serve critical loads. This paper proposed a resilience-oriented method to determine restoration strategies for secondary network distribution systems after a major disaster. Technical issues associated with the restoration process are analyzed, including the operation of network protectors, inrush currents caused by the energization of network transformers, synchronization of DGs to the network, and circulating currents among DGs. A look-ahead load restoration framework is proposed, incorporating technical issues associated with secondary networks, limitsmore » on DG capacity and generation resources, dynamic constraints, and operational limits. The entire outage duration is divided into a sequence of periods. Restoration strategies can be adjusted at the beginning of each period using the latest information. Finally, numerical simulation of the modified IEEE 342-node low voltage networked test system is performed to validate the effectiveness of the proposed method.« less

  19. Optimal Sizing of a Solar-Plus-Storage System for Utility Bill Savings and Resiliency Benefits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpkins, Travis; Anderson, Kate; Cutler, Dylan

    Solar-plus-storage systems can achieve significant utility savings in behind-the-meter deployments in buildings, campuses, or industrial sites. Common applications include demand charge reduction, energy arbitrage, time-shifting of excess photovoltaic (PV) production, and selling ancillary services to the utility grid. These systems can also offer some energy resiliency during grid outages. It is often difficult to quantify the amount of resiliency that these systems can provide, however, and this benefit is often undervalued or omitted during the design process. We propose a method for estimating the resiliency that a solar-plus-storage system can provide at a given location. We then present an optimizationmore » model that can optimally size the system components to minimize the lifecycle cost of electricity to the site, including the costs incurred during grid outages. The results show that including the value of resiliency during the feasibility stage can result in larger systems and increased resiliency.« less

  20. Optimal Sizing of a Solar-Plus-Storage System For Utility Bill Savings and Resiliency Benefits: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpkins, Travis; Anderson, Kate; Cutler, Dylan

    Solar-plus-storage systems can achieve significant utility savings in behind-the-meter deployments in buildings, campuses, or industrial sites. Common applications include demand charge reduction, energy arbitrage, time-shifting of excess photovoltaic (PV) production, and selling ancillary services to the utility grid. These systems can also offer some energy resiliency during grid outages. It is often difficult to quantify the amount of resiliency that these systems can provide, however, and this benefit is often undervalued or omitted during the design process. We propose a method for estimating the resiliency that a solar-plus-storage system can provide at a given location. We then present an optimizationmore » model that can optimally size the system components to minimize the lifecycle cost of electricity to the site, including the costs incurred during grid outages. The results show that including the value of resiliency during the feasibility stage can result in larger systems and increased resiliency.« less

  1. Evaluating the Magnitude and Duration of Cold Load Pick-up on Residential Distribution Feeders Using Multi-State Load Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, Kevin P.; Sortomme, Eric; Venkata, S. S.

    The increased level of demand that is associated with the restoration of service after an outage, Cold Load Pick-Up (CLPU), can be significantly higher than pre-outage levels, even exceeding the normal distribution feeder peak demand. These high levels of demand can delay restoration efforts and in extreme cases damage equipment. The negative impacts of CLPU can be mitigated with strategies that restore the feeder in sections, minimizing the load current. The challenge for utilities is to manage the current level on critical equipment while minimizing the time to restore service to all customers. Accurately modeling CLPU events is the firstmore » step in developing improved restoration strategies that minimize restoration times. This paper presents a new method for evaluating the magnitude of the CLPU peak, and its duration, using multi-state load models. The use of multi-state load models allows for a more accurate representation of the end-use loads that are present on residential distribution feeders.« less

  2. DGs for Service Restoration to Critical Loads in a Secondary Network

    DOE PAGES

    Xu, Yin; Liu, Chen-Ching; Wang, Zhiwen; ...

    2017-08-25

    During a major outage in a secondary network distribution system, distributed generators (DGs) connected to the primary feeders as well as the secondary network can be used to serve critical loads. This paper proposed a resilience-oriented method to determine restoration strategies for secondary network distribution systems after a major disaster. Technical issues associated with the restoration process are analyzed, including the operation of network protectors, inrush currents caused by the energization of network transformers, synchronization of DGs to the network, and circulating currents among DGs. A look-ahead load restoration framework is proposed, incorporating technical issues associated with secondary networks, limitsmore » on DG capacity and generation resources, dynamic constraints, and operational limits. The entire outage duration is divided into a sequence of periods. Restoration strategies can be adjusted at the beginning of each period using the latest information. Finally, numerical simulation of the modified IEEE 342-node low voltage networked test system is performed to validate the effectiveness of the proposed method.« less

  3. Computer-controlled wall servicing robot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lefkowitz, S.

    1995-03-01

    After four years of cooperative research, Pentek has unveiled a new robot with the capability to automatically deliver a variety of cleaning, painting, inspection, and surveillance devices to large vertical surfaces. The completely computer-controlled robot can position a working tool on a 50-foot tall by 50-foot wide vertical surface with a repeatability of 1/16 inch. The working end can literally {open_quotes}fly{close_quotes} across the face of a wall at speed of 60 per minute, and can handle working loads of 350 pounds. The robot was originally developed to decontaminate the walls of reactor fueling cavities at commercial nuclear power plants duringmore » fuel outages. If these cavities are left to dry after reactor refueling, contamination present in the residue could later become airborne and move throughout the containment building. Decontaminating the cavity during the refueling outage reduces the need for restrictive personal protective equipment during plant operations to limit the dose rates.« less

  4. Providing Limited Local Electric Service During a Major Grid Outage: A First Assessment Based on Customer Willingness to Pay.

    PubMed

    Baik, Sunhee; Morgan, M Granger; Davis, Alexander L

    2018-02-01

    While they are rare, widespread blackouts of the bulk power system can result in large costs to individuals and society. If local distribution circuits remain intact, it is possible to use new technologies including smart meters, intelligent switches that can change the topology of distribution circuits, and distributed generation owned by customers and the power company, to provide limited local electric power service. Many utilities are already making investments that would make this possible. We use customers' measured willingness to pay to explore when the incremental investments needed to implement these capabilities would be justified. Under many circumstances, upgrades in advanced distribution systems could be justified for a customer charge of less than a dollar a month (plus the cost of electricity used during outages), and would be less expensive and safer than the proliferation of small portable backup generators. We also discuss issues of social equity, extreme events, and various sources of underlying uncertainty. © 2017 Society for Risk Analysis.

  5. Performance Analysis of Amplify-and-Forward Systems with Single Relay Selection in Correlated Environments.

    PubMed

    Van Nguyen, Binh; Kim, Kiseon

    2016-09-11

    In this paper, we consider amplify-and-forward (AnF) cooperative systems under correlated fading environments. We first present a brief overview of existing works on the effect of channel correlations on the system performance. We then focus on our main contribution which is analyzing the outage probability of a multi-AnF-relay system with the best relay selection (BRS) scheme under a condition that two channels of each relay, source-relay and relay-destination channels, are correlated. Using lower and upper bounds on the end-to-end received signal-to-noise ratio (SNR) at the destination, we derive corresponding upper and lower bounds on the system outage probability. We prove that the system can achieve a diversity order (DO) equal to the number of relays. In addition, and importantly, we show that the considered correlation form has a constructive effect on the system performance. In other words, the larger the correlation coefficient, the better system performance. Our analytic results are corroborated by extensive Monte-Carlo simulations.

  6. Performance Analysis of an Inter-Relay Co-operation in FSO Communication System

    NASA Astrophysics Data System (ADS)

    Khanna, Himanshu; Aggarwal, Mona; Ahuja, Swaran

    2018-04-01

    In this work, we analyze the outage and error performance of a one-way inter-relay assisted free space optical link. The assumption of the absence of direct link between the source and destination node is being made for the analysis, and the feasibility of such system configuration is studied. We consider the influence of path loss, atmospheric turbulence and pointing error impairments, and investigate the effect of these parameters on the system performance. The turbulence-induced fading is modeled by independent but not necessarily identically distributed gamma-gamma fading statistics. The closed-form expressions for outage probability and probability of error are derived and illustrated by numerical plots. It is concluded that the absence of line of sight path between source and destination nodes does not lead to significant performance degradation. Moreover, for the system model under consideration, interconnected relaying provides better error performance than the non-interconnected relaying and dual-hop serial relaying techniques.

  7. Impact of Distributed Energy Resources on the Reliability of Critical Telecommunications Facilities: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, D. G.; Arent, D. J.; Johnson, L.

    2006-06-01

    This paper documents a probabilistic risk assessment of existing and alternative power supply systems at a large telecommunications office. The analysis characterizes the increase in the reliability of power supply through the use of two alternative power configurations. Failures in the power systems supporting major telecommunications service nodes are a main contributor to significant telecommunications outages. A logical approach to improving the robustness of telecommunication facilities is to increase the depth and breadth of technologies available to restore power during power outages. Distributed energy resources such as fuel cells and gas turbines could provide additional on-site electric power sources tomore » provide backup power, if batteries and diesel generators fail. The analysis is based on a hierarchical Bayesian approach and focuses on the failure probability associated with each of three possible facility configurations, along with assessment of the uncertainty or confidence level in the probability of failure. A risk-based characterization of final best configuration is presented.« less

  8. Dynamic analysis method for prevention of failure in the first-stage low-pressure turbine blade with two-finger root

    NASA Astrophysics Data System (ADS)

    Park, Jung-Yong; Jung, Yong-Keun; Park, Jong-Jin; Kang, Yong-Ho

    2002-05-01

    Failures of turbine blades are identified as the leading causes of unplanned outages for steam turbine. Accidents of low-pressure turbine blade occupied more than 70 percent in turbine components. Therefore, the prevention of failures for low pressure turbine blades is certainly needed. The procedure is illustrated by the case study. This procedure is used to guide, and support the plant manager's decisions to avoid a costly, unplanned outage. In this study, we are trying to find factors of failures in LP turbine blade and to make three steps to approach the solution of blade failure. First step is to measure natural frequency in mockup test and to compare it with nozzle passing frequency. Second step is to use FEM and to calculate the natural frequencies of 7 blades and 10 blades per group in BLADE code. Third step is to find natural frequencies of grouped blade off the nozzle passing frequency.

  9. 75 FR 6225 - Northern States Power Company-Minnesota; Prairie Island Nuclear Generating Plant Units 1 and 2...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-08

    ... modifications of this scope, and the impediments to construction such as the planned refueling outages at both... on the Internet at the NRC Web site: http://www.nrc.gov/reading-rm/adams.html . Persons who do not...

  10. 47 CFR 4.11 - Notification and initial and final communications outage reports that must be filed by...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... contained therein is true, correct, and accurate to the best of his/her knowledge and belief and that the... information that was not contained in, or that has changed from that provided in, the Initial report. The...

  11. 75 FR 76457 - FIFRA Scientific Advisory Panel; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-08

    ... public process provided only for convenience. If difficulties arise resulting in webcasting outages, the... submit. If EPA cannot read your comment due to technical difficulties and cannot contact you for... R. Matten, DFO, Office of Science Coordination and Policy (7201M), Environmental Protection Agency...

  12. 47 CFR 63.701 - Contents of application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Contents of application. 63.701 Section 63.701 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) EXTENSION OF LINES, NEW LINES, AND DISCONTINUANCE, REDUCTION, OUTAGE AND IMPAIRMENT OF SERVICE BY COMMON CARRIERS; AND GRANTS OF RECOGNIZED PRIVATE...

  13. 10 CFR 205.371 - Definition of emergency.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power § 205.371 Definition of... of the necessary fuels to generate electricity, or a regulatory action which prohibits the use of.... Where an electricity outage or service inadequacy qualifies for a section 202(c) order, contractual...

  14. 10 CFR 205.371 - Definition of emergency.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power § 205.371 Definition of... of the necessary fuels to generate electricity, or a regulatory action which prohibits the use of.... Where an electricity outage or service inadequacy qualifies for a section 202(c) order, contractual...

  15. 10 CFR 205.371 - Definition of emergency.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power § 205.371 Definition of... of the necessary fuels to generate electricity, or a regulatory action which prohibits the use of.... Where an electricity outage or service inadequacy qualifies for a section 202(c) order, contractual...

  16. 10 CFR 205.371 - Definition of emergency.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power § 205.371 Definition of... of the necessary fuels to generate electricity, or a regulatory action which prohibits the use of.... Where an electricity outage or service inadequacy qualifies for a section 202(c) order, contractual...

  17. 47 CFR 63.701 - Contents of application.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false Contents of application. 63.701 Section 63.701 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) EXTENSION OF LINES, NEW LINES, AND DISCONTINUANCE, REDUCTION, OUTAGE AND IMPAIRMENT OF SERVICE BY COMMON CARRIERS; AND GRANTS OF RECOGNIZED PRIVATE...

  18. Digital Troposcatter Performance Model: Software Documentation.

    DTIC Science & Technology

    1983-11-28

    Instantanous detection SNR. Output arguments: OUTISI R*4 Conditional outage probabilit.-. IERR 1*2 Error flag. Global variables input from commor IRSN /NUNPAR...meaning onlv when ITOFF = 3. - Possiblv given a new value in the following subprograms: TRANSF IRSN /NUMPAR/ 1*2 NUMPAR.INC Number of values in SNR

  19. 77 FR 67171 - Comprehensive Review of Licensing and Operating Rules for Satellite Services

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-08

    ... operators of space stations that carry common-carrier voice or paging communications to report outages of 30... addressing radio frequency interference characteristics and orbital parameters of space stations and revise... Vol. 77 Thursday, No. 217 November 8, 2012 Part III Federal Communications Commission 47 CFR Part...

  20. 7 CFR 1755.397 - RUS performance specification for line concentrators.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... importance in the design, manufacture and installation of the equipment. The equipment shall automatically... concentrator terminal units shall be designed such that there will be no more than 4 hours of total outages in... total signaling period. (ii) Subscriber dial interdigital time. The remote and central office LC...

  1. 76 FR 16410 - FIFRA Scientific Advisory Panel; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ... public process provided only for convenience. If difficulties arise resulting in webcasting outages, the... submit. If EPA cannot read your comment due to technical difficulties and cannot contact you for... Jenkins, Jr., PhD, DFO, Office of Science Coordination and Policy (7201M), Environmental Protection Agency...

  2. 76 FR 46798 - FIFRA Scientific Advisory Panel; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-03

    ... convenience. If difficulties arise resulting in webcasting outages, the meeting will continue as planned... difficulties and cannot contact you for clarification, EPA may not be able to consider your comment. Electronic... FURTHER INFORMATION CONTACT: Fred Jenkins, Jr., DFO, Office of Science Coordination and Policy (7201M...

  3. 75 FR 56101 - FIFRA Scientific Advisory Panel; Notice of Rescheduled Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-15

    ... provided only for convenience. If difficulties arise resulting in webcasting outages, the meeting will... difficulties and cannot contact you for clarification, EPA may not be able to consider your comment. Electronic... FURTHER INFORMATION CONTACT: Sharlene Matten, DFO, Office of Science Coordination and Policy (7201M...

  4. Securing the Internet Control Plane

    ERIC Educational Resources Information Center

    Benton, Kevin

    2017-01-01

    The Internet carries traffic between billions of devices every day and modern societies depend on the resiliency of the routing technology behind it to work around the frequent link outages caused by natural disasters, equipment failures, destruction of cables, and even wars. However, the routing technology behind all of this, the Border Gateway…

  5. 47 CFR 63.500 - Contents of applications to dismantle or remove a trunk line.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) COMMON CARRIER SERVICES (CONTINUED) EXTENSION OF LINES, NEW LINES, AND DISCONTINUANCE, REDUCTION, OUTAGE... which authorization is desired; (e) Proposed new tariff listing, if any, and difference, if any, between... service area affected including population and general character of business of the community; (g) Name of...

  6. National Marrow Donor Program

    DTIC Science & Technology

    2010-11-05

    from power or Internet outages to severe weather. • Received 50 mobile broadband air cards at minimal cost to the organization and ONR to allow for...CLlA CME CMF COG CREG CSS CT CTA DC DHHS-ASPR DIY DKMS DMSO DoD DNA DIR EBMT EM EMDIS ENS ERSI FBI QUARTER PROGRESS REPORT

  7. Putting Patience to the Test

    NASA Technical Reports Server (NTRS)

    Morgan, Ray

    2004-01-01

    A project manager recounts his decisions before and during the aftermath of the crash of a full-size flying model of Quetzalcoatlus northropi. The unstable pterodactyl crashed without harming anyone, although it caused a local power outage. The manager summarizes lessons learned about flight testing prototypes, including the effects of impatience.

  8. 47 CFR 63.62 - Type of discontinuance, reduction, or impairment of telephone or telegraph service requiring...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... impairment of telephone or telegraph service requiring formal application. 63.62 Section 63.62... LINES, NEW LINES, AND DISCONTINUANCE, REDUCTION, OUTAGE AND IMPAIRMENT OF SERVICE BY COMMON CARRIERS... Impairment § 63.62 Type of discontinuance, reduction, or impairment of telephone or telegraph service...

  9. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  10. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  11. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  12. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  13. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  14. 78 FR 18974 - Increasing Market and Planning Efficiency Through Improved Software; Notice of Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-28

    ... bring together experts from diverse backgrounds and experiences including electric system operators... transmission switching; AC optimal power flow modeling; and use of active and dynamic transmission ratings. In... variability of the system, including forecast error? [cir] How can outage probability be captured in...

  15. Computer Power. Part 2: Electrical Power Problems and Their Amelioration.

    ERIC Educational Resources Information Center

    Price, Bennett J.

    1989-01-01

    Describes electrical power problems that affect computer users, including spikes, sags, outages, noise, frequency variations, and static electricity. Ways in which these problems may be diagnosed and cured are discussed. Sidebars consider transformers; power distribution units; surge currents/linear and non-linear loads; and sizing the power…

  16. Academic Computing Vulnerabilities: Another View of the Roof

    ERIC Educational Resources Information Center

    Cohn, Ellen R.; Klinzing, George; Frieze, Irene Hanson; Sereika, Susan M.; Stone, Clement A.; Vana, Clara M.

    2004-01-01

    In anticipation of Y2K, and later as a result of heightened security concerns following the events of September 11, 2001, numerous colleges and universities developed formal planning documents to guide their responses to unexpected network outages. Typically, vigilant institutional financial auditors or information technology directors initiate…

  17. 76 FR 36892 - Proposed Extension of Part 4 of the Commission's Rules Regarding Outage Reporting to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-23

    ... technology; and (e) way to further reduce the information collection burden on small business concerns with... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 4 [PS Docket No. 11-82; FCC 11-74] Proposed... Communications Commission. ACTION: Proposed rule; correction. SUMMARY: The Federal Communications Commission...

  18. 40 CFR 270.14 - Contents of part B: General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... strata, surface water, or air, which may include the installation of wells, where the Director ascertains... water supplies; (iv) Mitigate effects of equipment failure and power outages; (v) Prevent undue exposure... contour interval must be sufficient to clearly show the pattern of surface water flow in the vicinity of...

  19. 76 FR 33686 - Proposed Extension of Part 4 of the Commission's Rules Regarding Outage Reporting to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-09

    ... broadband ISPs, a term which includes broadband Internet access service providers and broadband backbone... Internet consumers and businesses that purchase Internet access through less traditional access arrangements (e.g., prepaid Internet access cards). 23. Some broadband ISPs provide Internet access directly...

  20. Refinery Outages: Description and Potential Impact on Petroleum Product Prices

    EIA Publications

    2007-01-01

    This report responds to a July 13, 2006 request from Chairman Jeff Bingaman of the Senate Committee on Energy and Natural Resources requested that the Energy Information Administration conduct a study of the impact that refinery shutdowns have had on the price of oil and gasoline.

  1. 77 FR 7575 - Southwestern Gas Storage Technical Conference; Notice of Revised Agenda and Transcript Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... Commission. FERC/NERC Outage Report (Need Tom Pinkston, Office 9:20 for Storage). of Enforcement, Division of... of Pipeline Certificates; Tom Shaw, Vice President, Corporate Development, Voyager Midstream, LLC.... Customer Panel Norm Spooner--Arizona 2:30 Storage Coalition; Tom Carlson--Arizona Public Service Co...

  2. 49 CFR 173.24b - Additional general requirements for bulk packagings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... packagings. 173.24b Section 173.24b Transportation Other Regulations Relating to Transportation PIPELINE AND... SHIPPERS-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Preparation of Hazardous Materials for Transportation § 173.24b Additional general requirements for bulk packagings. (a) Outage and filling limits. (1...

  3. The Traffic Light Challenge

    ERIC Educational Resources Information Center

    Roman, Harry T.

    2014-01-01

    Traffic lights are an important part of the transportation infrastructure, regulating traffic flow and maintaining safety when crossing busy streets. When they go awry or become nonfunctional, a great deal of havoc and danger can be present. During power outages, the street lights go out all over the affected area. It would be good to be able to…

  4. 76 FR 17712 - In the Matter of Entergy Nuclear Vermont Yankee, LLC and Entergy Nuclear Operations, Inc...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ... completed to the Commission's satisfaction: (1) The tritiated groundwater remediation process; (2) the soil remediation process scheduled to take place during the refueling outage, to remove soil containing tritium and... leakage into the surrounding soil, and therefore to the groundwater, from an unsealed joint in the...

  5. 75 FR 27986 - Electronic Filing System-Web (EFS-Web) Contingency Option

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-19

    ...] Electronic Filing System--Web (EFS-Web) Contingency Option AGENCY: United States Patent and Trademark Office... availability of its patent electronic filing system, Electronic Filing System--Web (EFS-Web) by providing a new contingency option when the primary portal to EFS-Web has an unscheduled outage. Previously, the entire EFS...

  6. Disaster Recovery: Courting Disaster

    ERIC Educational Resources Information Center

    O'Hanlon, Charlene

    2007-01-01

    An inadequate or nonexistent disaster recovery plan can have dire results. Fire, power outage, and severe weather all can brin down the best of networks in an instant. This article draws on the experiences of the Charlotte County Public Schools (Port Charlotte, Florida), which were able to lessen the damage caused by Hurricane Charley when it hit…

  7. 47 CFR 4.5 - Definitions of outage, special offices and facilities, and 911 special facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... facilities, and 911 special facilities. 4.5 Section 4.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.5... significant degradation in the ability of an end user to establish and maintain a channel of communications as...

  8. User Delay Cost Model and Facilities Maintenance Cost Model for a Terminal Control Area : Volume 1. Model Formulation and Demonstration

    DOT National Transportation Integrated Search

    1978-05-01

    The User Delay Cost Model (UDCM) is a Monte Carlo computer simulation of essential aspects of Terminal Control Area (TCA) air traffic movements that would be affected by facility outages. The model can also evaluate delay effects due to other factors...

  9. 3 CFR 8386 - Proclamation 8386 of May 26, 2009. National Hurricane Preparedness Week, 2009

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... coastal and inland communities. These powerful storms can cause heavy rainfall, high winds, tornadoes, and storm surges, which can in turn bring severe flooding, power outages, damage to homes and businesses... property of those who face advancing storms. Americans can take basic steps before a hurricane arrives. The...

  10. Tornadoes and transmission reliability planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teles, J.E.; Anderson, S.W.; Landgren, G.L.

    1980-01-01

    The objective of this paper is to introduce an analytical approach for predicting overhead transmission line outages that are caused by tornadoes. The method is presently being used to determine the effects of tornadoes on various right-of-way configurations associated with a generating station project or the supply to a major substation. 2 refs.

  11. 40 CFR 270.290 - What general types of information must I keep at my facility?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and power outages, (5) Prevent undue exposure of personnel to hazardous waste (for example, requiring.... (n) [Reserved] (o) The most recent closure cost estimate for your facility prepared under 40 CFR 267... land uses (residential, commercial, agricultural, recreational). (5) A wind rose (i.e., prevailing wind...

  12. 40 CFR 270.290 - What general types of information must I keep at my facility?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and power outages, (5) Prevent undue exposure of personnel to hazardous waste (for example, requiring.... (n) [Reserved] (o) The most recent closure cost estimate for your facility prepared under 40 CFR 267... land uses (residential, commercial, agricultural, recreational). (5) A wind rose (i.e., prevailing wind...

  13. Disaster Response and Planning for Libraries, Third Edition

    ERIC Educational Resources Information Center

    Kahn, Miriam B.

    2012-01-01

    Fire, water, mold, construction problems, power-outages--mishaps like these can not only bring library services to a grinding halt, but can also destroy collections and even endanger employees. Preparing for the unexpected is the foundation of a library's best response. Expert Kahn comes to the rescue with this timely update of the best…

  14. 75 FR 30078 - Entergy Nuclear Operations, Inc.; Entergy Nuclear Vermont Yankee, LLC; Vermont Yankee Nuclear...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... remediation work and relevant reports on leaking tritium at the plant have been completed. Specifically, the... has been completed to the Commission's satisfaction: (1) The tritiated groundwater remediation process; (2) the soil remediation process scheduled to take place during the refueling outage, to remove soil...

  15. Communications Blackout Prediction for Atmospheric Entry of Mars Science Laboratory

    NASA Technical Reports Server (NTRS)

    Morabito, David; Edquist, Karl

    2005-01-01

    When a supersonic spacecraft enters a planetary atmosphere with v >> v(sub sound), a shock layer forms in the front of the body. An ionized sheath of plasma develops around the spacecraft, which results from the ionization of the atmospheric constituents as they are compressed and heated by the shock or heated within the boundary layer next to the surface. When the electron density surrounding the spacecraft becomes sufficiently high, communications can be disrupted (attenuation/blackout). During Mars Science Laboratory's (MSL's) atmospheric entry there will likely be a communication outage due to charged particles on the order of 60 to 100 seconds using a UHF link frequency looking out the shoulders of the wake region to orbiting relay asset. A UHF link looking out the base region would experience a shorter duration blackout, about 35 seconds for the stressed trajectory and possibly no blackout for the nominal trajectory. There is very little likelihood of a communications outage using X-band (however, X-band is not currently planned to be used during peak electron density phase of EDL).

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, S. R.; Daniel, A.

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy?s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icingmore » properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, Scott Robert

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkablemore » anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.« less

  18. 242A Distributed Control System Year 2000 Acceptance Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEATS, M.C.

    1999-08-31

    This report documents acceptance test results for the 242-A Evaporator distributive control system upgrade to D/3 version 9.0-2 for year 2000 compliance. This report documents the test results obtained by acceptance testing as directed by procedure HNF-2695. This verification procedure will document the initial testing and evaluation of the potential 242-A Distributed Control System (DCS) operating difficulties across the year 2000 boundary and the calendar adjustments needed for the leap year. Baseline system performance data will be recorded using current, as-is operating system software. Data will also be collected for operating system software that has been modified to correct yearmore » 2000 problems. This verification procedure is intended to be generic such that it may be performed on any D/3{trademark} (GSE Process Solutions, Inc.) distributed control system that runs with the VMSTM (Digital Equipment Corporation) operating system. This test may be run on simulation or production systems depending upon facility status. On production systems, DCS outages will occur nine times throughout performance of the test. These outages are expected to last about 10 minutes each.« less

  19. Performance Analysis of Amplify-and-Forward Systems with Single Relay Selection in Correlated Environments

    PubMed Central

    Nguyen, Binh Van; Kim, Kiseon

    2016-01-01

    In this paper, we consider amplify-and-forward (AnF) cooperative systems under correlated fading environments. We first present a brief overview of existing works on the effect of channel correlations on the system performance. We then focus on our main contribution which is analyzing the outage probability of a multi-AnF-relay system with the best relay selection (BRS) scheme under a condition that two channels of each relay, source-relay and relay-destination channels, are correlated. Using lower and upper bounds on the end-to-end received signal-to-noise ratio (SNR) at the destination, we derive corresponding upper and lower bounds on the system outage probability. We prove that the system can achieve a diversity order (DO) equal to the number of relays. In addition, and importantly, we show that the considered correlation form has a constructive effect on the system performance. In other words, the larger the correlation coefficient, the better system performance. Our analytic results are corroborated by extensive Monte-Carlo simulations. PMID:27626426

  20. Outage Probability of MRC for κ-μ Shadowed Fading Channels under Co-Channel Interference.

    PubMed

    Chen, Changfang; Shu, Minglei; Wang, Yinglong; Yang, Ming; Zhang, Chongqing

    2016-01-01

    In this paper, exact closed-form expressions are derived for the outage probability (OP) of the maximal ratio combining (MRC) scheme in the κ-μ shadowed fading channels, in which both the independent and correlated shadowing components are considered. The scenario assumes the received desired signals are corrupted by the independent Rayleigh-faded co-channel interference (CCI) and background white Gaussian noise. To this end, first, the probability density function (PDF) of the κ-μ shadowed fading distribution is obtained in the form of a power series. Then the incomplete generalized moment-generating function (IG-MGF) of the received signal-to-interference-plus-noise ratio (SINR) is derived in the closed form. By using the IG-MGF results, closed-form expressions for the OP of MRC scheme are obtained over the κ-μ shadowed fading channels. Simulation results are included to validate the correctness of the analytical derivations. These new statistical results can be applied to the modeling and analysis of several wireless communication systems, such as body centric communications.

  1. Outage Probability of MRC for κ-μ Shadowed Fading Channels under Co-Channel Interference

    PubMed Central

    Chen, Changfang; Shu, Minglei; Wang, Yinglong; Yang, Ming; Zhang, Chongqing

    2016-01-01

    In this paper, exact closed-form expressions are derived for the outage probability (OP) of the maximal ratio combining (MRC) scheme in the κ-μ shadowed fading channels, in which both the independent and correlated shadowing components are considered. The scenario assumes the received desired signals are corrupted by the independent Rayleigh-faded co-channel interference (CCI) and background white Gaussian noise. To this end, first, the probability density function (PDF) of the κ-μ shadowed fading distribution is obtained in the form of a power series. Then the incomplete generalized moment-generating function (IG-MGF) of the received signal-to-interference-plus-noise ratio (SINR) is derived in the closed form. By using the IG-MGF results, closed-form expressions for the OP of MRC scheme are obtained over the κ-μ shadowed fading channels. Simulation results are included to validate the correctness of the analytical derivations. These new statistical results can be applied to the modeling and analysis of several wireless communication systems, such as body centric communications. PMID:27851817

  2. Earth-space links and fade-duration statistics

    NASA Technical Reports Server (NTRS)

    Davarian, Faramaz

    1995-01-01

    In recent years, fade-duration statistics have been the subject of several experimental investigations. A good knowledge of the fade-duration distribution is important for the assessment of a satellite communication system's channel dynamics: What is a typical link outage duration? How often do link outages exceeding a given duration occur? Unfortunately there is yet no model that can universally answer the above questions. The available field measurements mainly come from temperate climatic zones and only from a few sites. Furthermore, the available statistics are also limited in the choice of frequency and path elevation angle. Yet, much can be learned from the available information. For example, we now know that the fade-duration distribution is approximately lognormal. Under certain conditions, we can even determine the median and other percentiles of the distribution. This paper reviews the available data obtained by several experimenters in different parts of the world. Areas of emphasis are mobile and fixed satellite links. Fades in mobile links are due to roadside-tree shadowing, whereas fades in fixed links are due to rain attenuation.

  3. Earth-Space Links and Fade-Duration Statistics

    NASA Technical Reports Server (NTRS)

    Davarian, Faramaz

    1996-01-01

    In recent years, fade-duration statistics have been the subject of several experimental investigations. A good knowledge of the fade-duration distribution is important for the assessment of a satellite communication system's channel dynamics: What is a typical link outage duration? How often do link outages exceeding a given duration occur? Unfortunately there is yet no model that can universally answer the above questions. The available field measurements mainly come from temperate climatic zones and only from a few sites. Furthermore, the available statistics are also limited in the choice of frequency and path elevation angle. Yet, much can be learned from the available information. For example, we now know that the fade-duration distribution is approximately lognormal. Under certain conditions, we can even determine the median and other percentiles of the distribution. This paper reviews the available data obtained by several experimenters in different parts of the world. Areas of emphasis are mobile and fixed satellite links. Fades in mobile links are due to roadside-tree shadowing, whereas fades in fixed links are due to rain attenuation.

  4. Impact of distributed energy resources on the reliability of a critical telecommunications facility.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, David; Zuffranieri, Jason V.; Atcitty, Christopher B.

    2006-03-01

    This report documents a probabilistic risk assessment of an existing power supply system at a large telecommunications office. The focus is on characterizing the increase in the reliability of power supply through the use of two alternative power configurations. Telecommunications has been identified by the Department of Homeland Security as a critical infrastructure to the United States. Failures in the power systems supporting major telecommunications service nodes are a main contributor to major telecommunications outages. A logical approach to improve the robustness of telecommunication facilities would be to increase the depth and breadth of technologies available to restore power inmore » the face of power outages. Distributed energy resources such as fuel cells and gas turbines could provide one more onsite electric power source to provide backup power, if batteries and diesel generators fail. The analysis is based on a hierarchical Bayesian approach and focuses on the failure probability associated with each of three possible facility configurations, along with assessment of the uncertainty or confidence level in the probability of failure. A risk-based characterization of final best configuration is presented.« less

  5. An Overview of Scientific and Space Weather Results from the Communication/Navigation Outage Forecasting System (C/NOFS) Mission

    NASA Technical Reports Server (NTRS)

    Pfaff, R.; de la Beaujardiere, O.; Hunton, D.; Heelis, R.; Earle, G.; Strauss, P.; Bernhardt, P.

    2012-01-01

    The Communication/Navigation Outage Forecasting System (C/NOFS) Mission of the Air Force Research Laboratory is described. C/NOFS science objectives may be organized into three categories: (1) to understand physical processes active in the background ionosphere and thermosphere in which plasma instabilities grow; (2) to identify mechanisms that trigger or quench the plasma irregularities responsible for signal degradation; and (3) to determine how the plasma irregularities affect the propagation of electromagnetic waves. The satellite was launched in April, 2008 into a low inclination (13 deg), elliptical (400 x 850 km) orbit. The satellite sensors measure the following parameters in situ: ambient and fluctuating electron densities, AC and DC electric and magnetic fields, ion drifts and large scale ion composition, ion and electron temperatures, and neutral winds. C/NOFS is also equipped with a GPS occultation receiver and a radio beacon. In addition to the satellite sensors, complementary ground-based measurements, theory, and advanced modeling techniques are also important parts of the mission. We report scientific and space weather highlights of the mission after nearly four years in orbit

  6. Index-based reactive power compensation scheme for voltage regulation

    NASA Astrophysics Data System (ADS)

    Dike, Damian Obioma

    2008-10-01

    Increasing demand for electrical power arising from deregulation and the restrictions posed to the construction of new transmission lines by environment, socioeconomic, and political issues had led to higher grid loading. Consequently, voltage instability has become a major concern, and reactive power support is vital to enhance transmission grid performance. Improved reactive power support to distressed grid is possible through the application of relatively unfamiliar emerging technologies of "Flexible AC Transmission Systems (FACTS)" devices and "Distributed Energy Resources (DERS)." In addition to these infrastructure issues, a lack of situational awareness by system operators can cause major power outages as evidenced by the August 14, 2003 widespread North American blackout. This and many other recent major outages have highlighted the inadequacies of existing power system indexes. In this work, a novel "Index-based reactive compensation scheme" appropriate for both on-line and off-line computation of grid status has been developed. A new voltage stability index (Ls-index) suitable for long transmission lines was developed, simulated, and compared to the existing two-machine modeled L-index. This showed the effect of long distance power wheeling amongst regional transmission organizations. The dissertation further provided models for index modulated voltage source converters (VSC) and index-based load flow analysis of both FACTS and microgrid interconnected power systems using the Newton-Raphson's load flow model incorporated with multi-FACTS devices. The developed package has been made user-friendly through the embodiment of interactive graphical user interface and implemented on the IEEE 14, 30, and 300 bus systems. The results showed reactive compensation has system wide-effect, provided readily accessible system status indicators, ensured seamless DERs interconnection through new islanding modes and enhanced VSC utilization. These outcomes may contribute to optimal utilization of compensation devices and available transfer capability as well as reduce system outages through better regulation of power operating voltages.

  7. Water Distribution System Deficiencies and Gastrointestinal Illness: A Systematic Review and Meta-Analysis

    PubMed Central

    Gruber, Joshua S.; Colford, John M.

    2014-01-01

    Background: Water distribution systems are vulnerable to performance deficiencies that can cause (re)contamination of treated water and plausibly lead to increased risk of gastrointestinal illness (GII) in consumers. Objectives: It is well established that large system disruptions in piped water networks can cause GII outbreaks. We hypothesized that routine network problems can also contribute to background levels of waterborne illness and conducted a systematic review and meta-analysis to assess the impact of distribution system deficiencies on endemic GII. Methods: We reviewed published studies that compared direct tap water consumption to consumption of tap water re-treated at the point of use (POU) and studies of specific system deficiencies such as breach of physical or hydraulic pipe integrity and lack of disinfectant residual. Results: In settings with network malfunction, consumers of tap water versus POU-treated water had increased GII [incidence density ratio (IDR) = 1.34; 95% CI: 1.00, 1.79]. The subset of nonblinded studies showed a significant association between GII and tap water versus POU-treated water consumption (IDR = 1.52; 95% CI: 1.05, 2.20), but there was no association based on studies that blinded participants to their POU water treatment status (IDR = 0.98; 95% CI: 0.90, 1.08). Among studies focusing on specific network deficiencies, GII was associated with temporary water outages (relative risk = 3.26; 95% CI: 1.48, 7.19) as well as chronic outages in intermittently operated distribution systems (odds ratio = 1.61; 95% CI: 1.26, 2.07). Conclusions: Tap water consumption is associated with GII in malfunctioning distribution networks. System deficiencies such as water outages also are associated with increased GII, suggesting a potential health risk for consumers served by piped water networks. Citation: Ercumen A, Gruber JS, Colford JM Jr. 2014. Water distribution system deficiencies and gastrointestinal illness: a systematic review and meta-analysis. Environ Health Perspect 122:651–660; http://dx.doi.org/10.1289/ehp.1306912 PMID:24659576

  8. Electric system restructuring and system reliability

    NASA Astrophysics Data System (ADS)

    Horiuchi, Catherine Miller

    In 1996 the California legislature passed AB 1890, explicitly defining economic benefits and detailing specific mechanisms for initiating a partial restructuring the state's electric system. Critics have since sought re-regulation and proponents have asked for patience as the new institutions and markets take shape. Other states' electric system restructuring activities have been tempered by real and perceived problems in the California model. This study examines the reduced regulatory controls and new constraints introduced in California's limited restructuring model using utility and regulatory agency records from the 1990's to investigate effects of new institutions and practices on system reliability for the state's five largest public and private utilities. Logit and negative binomial regressions indicate negative impact from the California model of restructuring on system reliability as measured by customer interruptions. Time series analysis of outage data could not predict the wholesale power market collapse and the subsequent rolling blackouts in early 2001; inclusion of near-outage reliability disturbances---load shedding and energy emergencies---provided a measure of forewarning. Analysis of system disruptions, generation capacity and demand, and the role of purchased power challenge conventional wisdom on the causality of Californian's power problems. The quantitative analysis was supplemented by a targeted survey of electric system restructuring participants. Findings suggest each utility and the organization controlling the state's electric grid provided protection from power outages comparable to pre-restructuring operations through 2000; however, this reliability has come at an inflated cost, resulting in reduced system purchases and decreased marginal protection. The historic margin of operating safety has fully eroded, increasing mandatory load shedding and emergency declarations for voluntary and mandatory conservation. Proposed remedies focused on state-funded contracts and government-managed power authorities may not help, as the findings suggest pricing models, market uncertainty, interjurisdictional conflict and an inability to respond to market perturbations are more significant contributors to reduced regional generation availability than the particular contract mechanisms and funding sources used for power purchases.

  9. Novel Hybrid of LS-SVM and Kalman Filter for GPS/INS Integration

    NASA Astrophysics Data System (ADS)

    Xu, Zhenkai; Li, Yong; Rizos, Chris; Xu, Xiaosu

    Integration of Global Positioning System (GPS) and Inertial Navigation System (INS) technologies can overcome the drawbacks of the individual systems. One of the advantages is that the integrated solution can provide continuous navigation capability even during GPS outages. However, bridging the GPS outages is still a challenge when Micro-Electro-Mechanical System (MEMS) inertial sensors are used. Methods being currently explored by the research community include applying vehicle motion constraints, optimal smoother, and artificial intelligence (AI) techniques. In the research area of AI, the neural network (NN) approach has been extensively utilised up to the present. In an NN-based integrated system, a Kalman filter (KF) estimates position, velocity and attitude errors, as well as the inertial sensor errors, to output navigation solutions while GPS signals are available. At the same time, an NN is trained to map the vehicle dynamics with corresponding KF states, and to correct INS measurements when GPS measurements are unavailable. To achieve good performance it is critical to select suitable quality and an optimal number of samples for the NN. This is sometimes too rigorous a requirement which limits real world application of NN-based methods.The support vector machine (SVM) approach is based on the structural risk minimisation principle, instead of the minimised empirical error principle that is commonly implemented in an NN. The SVM can avoid local minimisation and over-fitting problems in an NN, and therefore potentially can achieve a higher level of global performance. This paper focuses on the least squares support vector machine (LS-SVM), which can solve highly nonlinear and noisy black-box modelling problems. This paper explores the application of the LS-SVM to aid the GPS/INS integrated system, especially during GPS outages. The paper describes the principles of the LS-SVM and of the KF hybrid method, and introduces the LS-SVM regression algorithm. Field test data is processed to evaluate the performance of the proposed approach.

  10. 77 FR 76139 - Self-Regulatory Organizations; NYSE Arca, Inc.; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ... happen because of a temporary systems outage, a communications issue between the electronic and floor... Commission's Internet comment form ( http://www.sec.gov/rules/sro.shtml ); or Send an email to rule-comments... Commission will post all comments on the Commission's Internet Web site ( http://www.sec.gov/rules/sro.shtml...

  11. 77 FR 74788 - Long-Term Cooling and Unattended Water Makeup of Spent Fuel Pools

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-18

    ... frequency estimate of 1 in 100 years (1E-2/yr) for extreme space weather/ geomagnetic disturbance to perform... Accidents B. Geomagnetic Storms and Effects on the Earth C. Frequency of Geomagnetic Storms With Potential... commercial electric power grids are vulnerable to prolonged outage caused by extreme space weather, such as...

  12. 47 CFR 63.66 - Closure of or reduction of hours of service at telephone exchanges at military establishments.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Closure of or reduction of hours of service at telephone exchanges at military establishments. 63.66 Section 63.66 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) EXTENSION OF LINES, NEW LINES, AND DISCONTINUANCE, REDUCTION, OUTAGE AND...

  13. Gulf Coast Hurricanes Situation Report #39

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2005-11-09

    There are 49,300 customers without power in Florida as of 7:00 AM EST 11/9 due to Hurricane Wilma, down from a peak of about 3.6 million customers. Currently, less than 1 percent of the customers are without power in the state. This is the last report we will due on outages due to Hurricane Wilma.

  14. 77 FR 68196 - Orders Limiting Operations at John F. Kennedy International Airport, LaGuardia Airport, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-15

    ... to an extratropical storm that caused widespread power outages, severe flooding, and severe... storm. FAA Analysis Under the FAA's High Density Rule at DCA and Orders limiting operations at LGA, JFK... area or northeastern U.S. affected by the storm. These circumstances may have created a unique hardship...

  15. Stormwise: Integrating arboriculture and silviculture to create storm-resilient roadside forests

    Treesearch

    Jeffrey S. Ward; Thomas E. Worthley; Thomas J. Degnan; Joseph P. Barsky

    2017-01-01

    The band of trees within 30 m of roads (i.e., roadside forests) is often left unmanaged during traditional forest management activities because of liability concerns about inadvertently causing a vehicular accident or damaging utility lines during harvests. The trees in these same neglected forests often cause extensive utility outages and road blockages during extreme...

  16. 47 CFR 63.505 - Contents of applications for any type of discontinuance, reduction, or impairment of telephone...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... discontinuance, reduction, or impairment of telephone service not specifically provided for in this part. 63.505... (CONTINUED) EXTENSION OF LINES, NEW LINES, AND DISCONTINUANCE, REDUCTION, OUTAGE AND IMPAIRMENT OF SERVICE BY...; Examples § 63.505 Contents of applications for any type of discontinuance, reduction, or impairment of...

  17. 40 CFR Appendix A to Subpart Uuuuu - Hg Monitoring Provisions

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... “cold standby” and may be reinstalled in the event of a primary monitoring system outage. A non... 40 Protection of Environment 15 2012-07-01 2012-07-01 false Hg Monitoring Provisions A Appendix A... Generating Units Pt. 63, Subpt. UUUUU, App. A Appendix A to Subpart UUUUU—Hg Monitoring Provisions 1. General...

  18. 77 FR 53886 - February 2011 Southwest Cold Weather Event Follow-up Technical Conference; Notice of Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-04

    ... Southwest Cold Weather Event Follow-up Technical Conference; Notice of Technical Conference Take notice that... August 16, 2011 Report on Outages and Curtailments During the Southwest Cold Weather Event of February 1... severe cold weather issues that led to rolling blackouts affecting over 4 million customers and natural...

  19. Academic Continuity: Staying True to Teaching Values and Objectives in the Face of Course Interruptions

    ERIC Educational Resources Information Center

    Day, Terence

    2015-01-01

    Academic continuity planning is an emerging tool for dealing with class cancellation associated with natural disasters, acts of violence and the threat of pandemics. However, academic continuity can also be an issue with respect to less dramatic events, such as power outages, inclement weather, or the temporary unavailability of an instructor,…

  20. 77 FR 15098 - AES Hawaii, Inc.; Notice of Petition for Temporary Waiver

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-14

    ...] AES Hawaii, Inc.; Notice of Petition for Temporary Waiver Take notice that on March 5, 2012, pursuant... and Procedure, 18 CFR 292.205(c), AES Hawaii, Inc. (AES Hawaii) filed a Request for Temporary Waiver..., Hawaii. AES Hawaii makes such a request because of a forced boiler outage in the fourth quarter of 2011...

  1. Water Network Tool for Resilience v. 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-12-09

    WNTR is a python package designed to simulate and analyze resilience of water distribution networks. The software includes: - Pressure driven and demand driven hydraulic simulation - Water quality simulation to track concentration, trace, and water age - Conditional controls to simulate power outages - Models to simulate pipe breaks - A wide range of resilience metrics - Analysis and visualization tools

  2. Theoretical Limits on Multiuser Molecular Communication in Internet of Nano-Bio Things.

    PubMed

    Dinc, Ergin; Akan, Ozgur B

    2017-06-01

    In nano-bio networks, multiple transmitter-receiver pairs will operate in the same medium. Both inter-symbol interference and multi-user interference can cause saturation at the receiver side, and this effect may cause an outage. Thus, we propose a tractable framework to calculate the theoretical operating points for fully absorbing receiver.

  3. REopt Lite Web Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NREL developed a free, publicly available web version of the REopt (TM) renewable energy integration and optimization platform called REopt Lite. REopt Lite recommends the optimal size and dispatch strategy for grid-connected photovoltaics (PV) and battery storage at a site. It also allows users to explore how PV and storage can increase a site's resiliency during a grid outage.

  4. 76 FR 6836 - Entergy Operations, Inc.; Notice of Withdrawal of Application for Amendment to Facility Operating...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-08

    .... NPF-38 for the Waterford Steam Electric Station, Unit 3, located in St. Charles Parish, Louisiana. In view of the originally planned steam generator (SG) replacement during the spring 2011 refueling outage... to TS 6.5.9, ``Steam Generator (SG) Program,'' and TS 6.9.1.5, ``Steam Generator Tube Inspection...

  5. 75 FR 16222 - Self-Regulatory Organizations; Notice of Filing and Immediate Effectiveness of Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-31

    ... liability for system outages. The text of the proposed rule change is attached as Exhibit 5 to the 19b-4...: Electronic Comments Use the Commission's Internet comment form ( http://www.sec.gov/rules/sro.shtml ); or... method. The Commission will post all comments on the Commission's Internet Web site ( http://www.sec.gov...

  6. An Extensible Sensing and Control Platform for Building Energy Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rowe, Anthony; Berges, Mario; Martin, Christopher

    2016-04-03

    The goal of this project is to develop Mortar.io, an open-source BAS platform designed to simplify data collection, archiving, event scheduling and coordination of cross-system interactions. Mortar.io is optimized for (1) robustness to network outages, (2) ease of installation using plug-and-play and (3) scalable support for small to large buildings and campuses.

  7. "Stronger than the Storm": Keeping Infants and Young Children in Mind During the Response to Superstorm Sandy

    ERIC Educational Resources Information Center

    Costa, Gerard; Mulrooney, Kathleen; Spinazzola, Nicci

    2013-01-01

    Superstorm Sandy hit the coast of New Jersey with deadly force causing hundreds of miles of coastline damage, loss of homes, property and road damage, and power outages throughout the region. despite the state's strong disaster response network, most programs and responders have little background in supporting the needs of infants and very young…

  8. Lights Out: Foreseeable Catastrophic Effects of Geomagnetic Storms on the North American Power Grid and How to Mitigate Them

    DTIC Science & Technology

    2011-08-21

    poultry, pork , beef, fish, and other meat products also are typically automated operations, done on electrically driven processing lines. 53 Food ...Infrastructure ..................................................... 18 Power Outage Impact on Consumables ( Food , Water, Medication...transportation, consumables ( food , water, and medication), and emergency services, are so highly dependent on reliable power supply from the grid, a

  9. Mobile Robot Pose Tracking for Performance Analysis

    DTIC Science & Technology

    2002-08-01

    of Applanix POS LV 420 Intertial Navigation Unit (HMMWV Test Vehicle). GPS Outage Duration (minutes)POS LV 420-RT (using DGPS) 0 min 1 min 3 min 5...0.02 0.02 0.02 True Heading (deg) 0.02 0.02 0.02 0.04 0.06 0.10 0.20 Table 3: Performance of Applanix LV 420 with post-processing (HMMWV Test Vehicle

  10. Channel Deviation-Based Power Control in Body Area Networks.

    PubMed

    Van, Son Dinh; Cotton, Simon L; Smith, David B

    2018-05-01

    Internet enabled body area networks (BANs) will form a core part of future remote health monitoring and ambient assisted living technology. In BAN applications, due to the dynamic nature of human activity, the off-body BAN channel can be prone to deep fading caused by body shadowing and multipath fading. Using this knowledge, we present some novel practical adaptive power control protocols based on the channel deviation to simultaneously prolong the lifetime of wearable devices and reduce outage probability. The proposed schemes are both flexible and relatively simple to implement on hardware platforms with constrained resources making them inherently suitable for BAN applications. We present the key algorithm parameters used to dynamically respond to the channel variation. This allows the algorithms to achieve a better energy efficiency and signal reliability in everyday usage scenarios such as those in which a person undertakes many different activities (e.g., sitting, walking, standing, etc.). We also profile their performance against traditional, optimal, and other existing schemes for which it is demonstrated that not only does the outage probability reduce significantly, but the proposed algorithms also save up to average transmit power compared to the competing schemes.

  11. Downlink Cooperative Broadcast Transmission Based on Superposition Coding in a Relaying System for Future Wireless Sensor Networks.

    PubMed

    Liu, Yang; Han, Guangjie; Shi, Sulong; Li, Zhengquan

    2018-06-20

    This study investigates the superiority of cooperative broadcast transmission over traditional orthogonal schemes when applied in a downlink relaying broadcast channel (RBC). Two proposed cooperative broadcast transmission protocols, one with an amplify-and-forward (AF) relay, and the other with a repetition-based decode-and-forward (DF) relay, are investigated. By utilizing superposition coding (SupC), the source and the relay transmit the private user messages simultaneously instead of sequentially as in traditional orthogonal schemes, which means the channel resources are reused and an increased channel degree of freedom is available to each user, hence the half-duplex penalty of relaying is alleviated. To facilitate a performance evaluation, theoretical outage probability expressions of the two broadcast transmission schemes are developed, based on which, we investigate the minimum total power consumption of each scheme for a given traffic requirement by numerical simulation. The results provide details on the overall system performance and fruitful insights on the essential characteristics of cooperative broadcast transmission in RBCs. It is observed that better overall outage performances and considerable power gains can be obtained by utilizing cooperative broadcast transmissions compared to traditional orthogonal schemes.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, W. D.; Restivo, M. L.; Martino, C. J.

    Radioactive waste samples retrieved from Savannah River Site (SRS) Tanks 38H and 43H (concentrate receipt and feed tanks, respectively, for the 2H Evaporator system) were evaluated with regard to their tendency to form foams during air sparging. This work was conducted due to recent processing issues and outages in the evaporator that were believed to have resulted from sample foaming. The samples evaluated for foam formation included supernate collected in April of 2014 (near the time of the evaporator outage) as well as historical samples available within the SRNL shielded cells facility. The April samples included one Tank 43H surfacemore » sample (HTF-43-14-42), one Tank 43H sub-surface sample (HTF-43-14-43), and one Tank 38H (HTF-38-14-41) surface sample. In addition, two Tank 43H samples (HTF-43-14-8 and HTF-43-14-9) and one Tank 38H sample (HTF-38-14-6) were also evaluated along with a blended sample of various historical Tank 38H and 43H samples. Characterization results for the April samples are also provided. The composition of the samples was similar to historical evaporator system samples received at SRNL.« less

  13. Characterization of the Body-to-Body Propagation Channel for Subjects during Sports Activities.

    PubMed

    Mohamed, Marshed; Cheffena, Michael; Moldsvor, Arild

    2018-02-18

    Body-to-body wireless networks (BBWNs) have great potential to find applications in team sports activities among others. However, successful design of such systems requires great understanding of the communication channel as the movement of the body components causes time-varying shadowing and fading effects. In this study, we present results of the measurement campaign of BBWN during running and cycling activities. Among others, the results indicated the presence of good and bad states with each state following a specific distribution for the considered propagation scenarios. This motivated the development of two-state semi-Markov model, for simulation of the communication channels. The simulation model was validated using the available measurement data in terms of first and second order statistics and have shown good agreement. The first order statistics obtained from the simulation model as well as the measured results were then used to analyze the performance of the BBWNs channels under running and cycling activities in terms of capacity and outage probability. Cycling channels showed better performance than running, having higher channel capacity and lower outage probability, regardless of the speed of the subjects involved in the measurement campaign.

  14. ORAM-SENTINEL{trademark} demonstration at Fitzpatrick. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, L.K.; Anderson, V.M.; Mohammadi, K.

    1998-06-01

    New York Power Authority, in cooperation with EPRI, installed the ORAM-SENTINEL{trademark} software at James A. Fitzpatrick (JAF) Nuclear Power Plant. This software incorporates models of safety systems and support systems that are used for defense-in-depth in the plant during outage and on-line periods. A secondary goal was to include some pre-analyzed risk results to validate the methodology for quantitative assessment of the plant risks during proposed on-line maintenance. During the past year, New York Power Authority personnel have become familiar with the formal computerized Safety Assessment process associated with on-line and outage maintenance. The report describes techniques and lessons learnedmore » during development of the ORAM-SENTINEL model at JAF. It overviews the systems important to the Safety Function Assessment Process and provides details on development of the Plant Transient Assessment process using the station emergency operating procedures. The assessment results are displayed by color (green, yellow, orange, red) to show decreasing safety conditions. The report describes use of the JAF Probabilistic Safety Assessment within the ORAM-SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator.« less

  15. Design and field test of collaborative tools in the service of an innovative organization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Beler, N.; Parfouru, S.

    2012-07-01

    This paper presents the design process of collaborative tools, based on ICT, aiming at supporting the tasks of the team that manages an outage of an energy production plant for maintenance activities. The design process follows an iterative and multidisciplinary approach, based on a collective tasks modeling of the outage management team in the light of Socio Organizational and Human (SOH) field studies, and on the state of the art of ICT. Field test of the collaborative tools designed plays a great place in this approach, allowing taking into account the operational world but involves also some risks which mustmore » be managed. To implement tools on all the production plants, we build an 'operational concept' with a level of description which authorizes the evolution of tools and allows some local adaptations. The field tests provide lessons on the ICT topics. For examples: the status of the remote access tools, the potential of use of a given information input by an actor for several individual and collective purposes, the actors perception of the tools meaning, and the requirements for supporting the implementation of change. (authors)« less

  16. Exact outage analysis of the effect of co-channel interference on secured multi-hop relaying networks

    NASA Astrophysics Data System (ADS)

    Quang Nguyen, Sang; Kong, Hyung Yun

    2016-11-01

    In this article, the presence of multi-hop relaying, eavesdropper and co-channel interference (CCI) in the same system model is investigated. Specifically, the effect of CCI on a secured multi-hop relaying network is studied, in which the source communicates with the destination via multi-relay-hopping under the presence of an eavesdropper and CCI at each node. The optimal relay at each cluster is selected to help forward the message from the source to the destination. We apply two relay selection approaches to such a system model, i.e. the optimal relay is chosen based on (1) the maximum channel gain from the transmitter to all relays in the desired cluster and (2) the minimum channel gain from the eavesdropper to all relays in each cluster. For the performance evaluation and comparison, we derived the exact closed form of the secrecy outage probability of the two approaches. That analysis is verified by Monte Carlo simulation. Finally, the effects of the number of hops, the transmit power at the source, relays and the external sources, the distance between the external sources and each node in the system, and the location of the eavesdropper are presented and discussed.

  17. Reduction of radiation exposure in Japanese BWR Nuclear Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morikawa, Yoshitake

    1995-03-01

    The reduction of occupational exposure to radiation during the annual inspection and maintenance outages of Japanese boiling water reactors (BWR) is one of the most important objectives for stable and reliable operation. It was shown that this radiation exposure is caused by radionuclides, such as Co-60, Co-58 and Mn-54 which are produced from the metal elements Co, Ni, and Fe present in the corrosion products of structural materials that had been irradiated by neutrons. Therefore, to reduce radiation sources and exposures in Japanese BWRs, attempts have been reinforced to remove corrosion products and activated corrosion products from the primary coolantmore » system. This paper describes the progress of the application of these measures to Japanese BWRs. Most Japanese BWR-4 and BWR-5 type nuclear power plants started their commercial operations during the 1970s. With the elapse of time during operations, a problem came to the forefront, namely that occupational radiation exposure during plant outages gradually increased, which obstructed the smooth running of inspections and maintenance work. To overcome this problem, extensive studies to derive effective countermeasures for radiation exposure reduction were undertaken, based on the evaluation of the plants operation data.« less

  18. Research for the Cable Layout Way of the Bypass Operation System in Agricultural Power Supply Network

    NASA Astrophysics Data System (ADS)

    Niu, Jie; Li, Jinliang; Zou, Dehua; Yang, Qi; Li, Xu; Yan, Yu; Li, Tang

    2017-05-01

    Non-blackout working of agricultural power supply network is significant to shorten the outage time, decrease the outage loss, and improve the supply reliability and safety. It is impossible to hang the wire rope first and then suspend the cable because of the poor bearing ability of the pole in agricultural power supply network. A kind of new cable arrangement way, its matching tools and the flexible cable that can bear the tension by itself are needed to be put forward and developed. It is necessary to calculate the electric field intensity of the flexible cable to verify that the electric field intensity meets the insulation demand. In this new design, the fiber layer is added into the flexible cable and its maximum tension force is measured to reach to 4000 N. Based on the features of live working in the agricultural power supply network, the new layout way of the cable is proposed; the matching tools and the new flexible cable that can bear the tension by itself are developed as well in this paper. All of the research achievements can give references for the live working of the agricultural power supply network.

  19. Non-Orthogonal Multiple Access for Ubiquitous Wireless Sensor Networks.

    PubMed

    Anwar, Asim; Seet, Boon-Chong; Ding, Zhiguo

    2018-02-08

    Ubiquitous wireless sensor networks (UWSNs) have become a critical technology for enabling smart cities and other ubiquitous monitoring applications. Their deployment, however, can be seriously hampered by the spectrum available to the sheer number of sensors for communication. To support the communication needs of UWSNs without requiring more spectrum resources, the power-domain non-orthogonal multiple access (NOMA) technique originally proposed for 5th Generation (5G) cellular networks is investigated for UWSNs for the first time in this paper. However, unlike 5G networks that operate in the licensed spectrum, UWSNs mostly operate in unlicensed spectrum where sensors also experience cross-technology interferences from other devices sharing the same spectrum. In this paper, we model the interferences from various sources at the sensors using stochastic geometry framework. To evaluate the performance, we derive a theorem and present new closed form expression for the outage probability of the sensors in a downlink scenario under interference limited environment. In addition, diversity analysis for the ordered NOMA users is performed. Based on the derived outage probability, we evaluate the average link throughput and energy consumption efficiency of NOMA against conventional orthogonal multiple access (OMA) technique in UWSNs. Further, the required computational complexity for the NOMA users is presented.

  20. Method for Evaluation of Outage Probability on Random Access Channel in Mobile Communication Systems

    NASA Astrophysics Data System (ADS)

    Kollár, Martin

    2012-05-01

    In order to access the cell in all mobile communication technologies a so called random-access procedure is used. For example in GSM this is represented by sending the CHANNEL REQUEST message from Mobile Station (MS) to Base Transceiver Station (BTS) which is consequently forwarded as an CHANNEL REQUIRED message to the Base Station Controller (BSC). If the BTS decodes some noise on the Random Access Channel (RACH) as random access by mistake (so- called ‘phantom RACH') then it is a question of pure coincidence which èstablishment cause’ the BTS thinks to have recognized. A typical invalid channel access request or phantom RACH is characterized by an IMMEDIATE ASSIGNMENT procedure (assignment of an SDCCH or TCH) which is not followed by sending an ESTABLISH INDICATION from MS to BTS. In this paper a mathematical model for evaluation of the Power RACH Busy Threshold (RACHBT) in order to guaranty in advance determined outage probability on RACH is described and discussed as well. It focuses on Global System for Mobile Communications (GSM) however the obtained results can be generalized on remaining mobile technologies (ie WCDMA and LTE).

  1. Investigating incidents of EHR failures in China: analysis of search engine reports.

    PubMed

    Lei, Jianbo; Guan, Pengcheng; Gao, Kaihua; Lu, Xueqing; Sittig, Dean

    2013-01-01

    As the healthcare industry becomes increasingly dependent on information technology (IT), the failure of computerized systems could cause catastrophic effects on patient safety. We conducted an empirical study to analyze news articles available on the internet using Baidu and Google. 116 distinct EHR outage news reports were identified. We examined characteristics, potential causes, and possible preventive strategies. Risk management strategies based are discussed.

  2. Power-line electrocution of birds (Electrocucion de Aves en Lineas Electricas en Mexico)

    Treesearch

    Patricia Manzano Fischer

    2006-01-01

    A result of rapid growth in human population and energy use, is proliferating power lines that electrocute birds, killing eagles and causing power outages. The United States was one of the first countries to recognize the significance of this problem. Suggested Practices for the Protection of Raptors on Power Lines, first published in the 1970s, has now been translated...

  3. Analysis of Cloud-Based Database Systems

    DTIC Science & Technology

    2015-06-01

    EU) citizens under the Patriot Act [3]. Unforeseen virtualization bugs have caused wide-reaching outages [4], leaving customers helpless to assist...collected from SQL Server Profiler traces. We analyze the trace results captured from our test bed both before and after increasing system resources...cloud test- bed . A. DATA COLLECTION, PARSING, AND ORGANIZATION Once we finished collecting the trace data, we knew we needed to have as close a

  4. Integration of Cold Atom Interferometry INS with Other Sensors

    DTIC Science & Technology

    2012-03-22

    Kalman filtering 2.6.1 Linear Kalman filtering . Kalman filtering is used to estimate the solution to a linear... Kalman Filter . This filter will estimate the errors in the navigation grade measurement. Whenever an outage occurs the mechanization must be done using ...navigation solution, with periodic GPS measurements being brought into a Kalman Filter to estimate the errors in the INS solution. The results of

  5. Impacts of Severe Space Weather on the Electric Grid

    DTIC Science & Technology

    2011-11-01

    toasters, for instance, will tend to slow the generator, as its rotational energy is converted to electrical energy. This signal is then used to provide...dividually to order. Recognizing the vulnerability of the grid to transformer outage, there have been efforts in recent years to provide modular ...that occur during geomagnetic disturbances’ [9], and ’ Multilevels of protection for individual apparatus such as generators, transformers

  6. Primary water chemistry improvement for radiation exposure reduction at Japanese PWR Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishizawa, Eiichi

    1995-03-01

    Radiation exposure during the refueling outages at Japanese Pressurized Water Reactor (PWR) Plants has been gradually decreased through continuous efforts keeping the radiation dose rates at relatively low level. The improvement of primary water chemistry in respect to reduction of the radiation sources appears as one of the most important contributions to the achieved results and can be classified by the plant operation conditions as follows

  7. Characterizing Open Source Routing Radio-to-Router Information in an Airborne Network

    DTIC Science & Technology

    2010-12-01

    understand the availability of the actual RF link. Link outages call be caused by a number of issues include airplane body blockage, bad antenna...34 .. ..... Hr. su ,.nnuullon ~I ~, Hr. n .1 _ , F_" ,"", ChoIk _ _ {U8 _ 0ftS - OftS IIU IIo) ZOO ..... I F’~ ’,"",Cho’u - IU8 - OftS) Il~l ,.. Moo

  8. A software framework for assessing the resilience of drinking ...

    EPA Pesticide Factsheets

    Journal article This paper introduces a new software tool called the Water Network Tool for Resilience (WNTR) that water utilities can use to assess their resilience to disasters. A case study of an earthquake is included that results in damage to pipes and tanks, fires, and power outages. The utility uses several response strategies including fixing damaged pipes and tanks, restoring power, fighting fires, and implementing conservation.

  9. Translations on Telecommunications Policy, Research and Development, Number 14

    DTIC Science & Technology

    1977-09-23

    Nationwide Microwave System Completed ( JUVENTUD REBELDE, 22 Jul 77) 28 Intercosmos Radar Laser Facility in Cuba Described (Luis Coronado; BOHEMIA, 24...radio jamming and also to our postwar era . This is how the Tobaru villagers feel about it." CSO: 5500 JAPAN BRIEFS KDD TELEX SERVICE OUTAGE--Tokyo...installed at Changi International Airport and be operational by October 1979. A digital air traffic control simulator, costing Singapore $4.8

  10. Warranty-Guarantee Application Guidelines for Air Force Ground Electronic Equipment.

    DTIC Science & Technology

    1980-02-01

    perform the on-equipment maintenance. The procedure is comparable to existing Mobile Depot Mainte- nance. The extended outage of failed equipment may be...currently computed. However, because the equipment is fixed geographically, in contrast to the mobility of avionics equipment, operating-time logs could...base environment, many other items of ground equip- ment are deployed at a remote location or, particularly in TAC, may be mobile equipment not

  11. 46 CFR 38.15-1 - Filling of tanks-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... that there is an outage of at least 2 percent of the volume of the tank at the temperature..., the maximum volume to which a tank may be loaded is: V L=0.98d r V/d L where: V L=maximum volume to which tank may be loaded. V=volume of tank. d r=density of cargo at the temperature required for a cargo...

  12. Automating Natural Disaster Impact Analysis: An Open Resource to Visually Estimate a Hurricane s Impact on the Electric Grid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barker, Alan M; Freer, Eva B; Omitaomu, Olufemi A

    An ORNL team working on the Energy Awareness and Resiliency Standardized Services (EARSS) project developed a fully automated procedure to take wind speed and location estimates provided by hurricane forecasters and provide a geospatial estimate on the impact to the electric grid in terms of outage areas and projected duration of outages. Hurricane Sandy was one of the worst US storms ever, with reported injuries and deaths, millions of people without power for several days, and billions of dollars in economic impact. Hurricane advisories were released for Sandy from October 22 through 31, 2012. The fact that the geoprocessing wasmore » automated was significant there were 64 advisories for Sandy. Manual analysis typically takes about one hour for each advisory. During a storm event, advisories are released every two to three hours around the clock, and an analyst capable of performing the manual analysis has other tasks they would like to focus on. Initial predictions of a big impact and landfall usually occur three days in advance, so time is of the essence to prepare for utility repair. Automated processing developed at ORNL allowed this analysis to be completed and made publicly available within minutes of each new advisory being released.« less

  13. Diagnosing causes of increased NO{sub x} at Potomac River Unit 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D`Agostini, M.; Levy, E.; Blankenship, D.

    1996-12-31

    Potomac River Unit 4, a 108 MW unit, has a corner-fired boiler with conventional burners. Through the use of combustion optimization techniques, the NO{sub x} emissions had been reduced from baseline levels of 0.6 lb/MBtu to values below 0.45 lb/MBtu over the load range, and had been routinely dispatched at this reduced emissions level for extended periods of operation. After a scheduled outage in Fall 1995 for boiler maintenance, windbox modifications and a superheater replacement, the unit was returned to service, and it was found that the full-load NO{sub x} level had increased by approximately 0.1 lb/MBtu. A week ofmore » tests was performed and pre- and post-outage data analyzed to determine the factors contributing to the increase in NO{sub x} emissions. The principal cause was found to be a reduction in the amount of boiler air in-leakage arising from boiler casing repairs, and leading to higher air-to-fuel ratios in the furnace. Other, secondary, causes were also determined. Results from the analysis indicate the windbox modifications were actually effective in reducing NO{sub x}, although the benefits were obscured due to the intervening circumstances. This paper describes the diagnostic process which was followed and discusses the findings from the investigation.« less

  14. Modeling of unit operating considerations in generating-capacity reliability evaluation. Volume 1. Mathematical models, computing methods, and results. Final report. [GENESIS, OPCON and OPPLAN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patton, A.D.; Ayoub, A.K.; Singh, C.

    1982-07-01

    Existing methods for generating capacity reliability evaluation do not explicitly recognize a number of operating considerations which may have important effects in system reliability performance. Thus, current methods may yield estimates of system reliability which differ appreciably from actual observed reliability. Further, current methods offer no means of accurately studying or evaluating alternatives which may differ in one or more operating considerations. Operating considerations which are considered to be important in generating capacity reliability evaluation include: unit duty cycles as influenced by load cycle shape, reliability performance of other units, unit commitment policy, and operating reserve policy; unit start-up failuresmore » distinct from unit running failures; unit start-up times; and unit outage postponability and the management of postponable outages. A detailed Monte Carlo simulation computer model called GENESIS and two analytical models called OPCON and OPPLAN have been developed which are capable of incorporating the effects of many operating considerations including those noted above. These computer models have been used to study a variety of actual and synthetic systems and are available from EPRI. The new models are shown to produce system reliability indices which differ appreciably from index values computed using traditional models which do not recognize operating considerations.« less

  15. Performance Analysis of Relay Subset Selection for Amplify-and-Forward Cognitive Relay Networks

    PubMed Central

    Qureshi, Ijaz Mansoor; Malik, Aqdas Naveed; Zubair, Muhammad

    2014-01-01

    Cooperative communication is regarded as a key technology in wireless networks, including cognitive radio networks (CRNs), which increases the diversity order of the signal to combat the unfavorable effects of the fading channels, by allowing distributed terminals to collaborate through sophisticated signal processing. Underlay CRNs have strict interference constraints towards the secondary users (SUs) active in the frequency band of the primary users (PUs), which limits their transmit power and their coverage area. Relay selection offers a potential solution to the challenges faced by underlay networks, by selecting either single best relay or a subset of potential relay set under different design requirements and assumptions. The best relay selection schemes proposed in the literature for amplify-and-forward (AF) based underlay cognitive relay networks have been very well studied in terms of outage probability (OP) and bit error rate (BER), which is deficient in multiple relay selection schemes. The novelty of this work is to study the outage behavior of multiple relay selection in the underlay CRN and derive the closed-form expressions for the OP and BER through cumulative distribution function (CDF) of the SNR received at the destination. The effectiveness of relay subset selection is shown through simulation results. PMID:24737980

  16. SPALLMAP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sabau, Adrian; Wright, Ian

    Boiler tubes in steam power plants experience exfoliation of oxide grown on the inner side of the tubes. In extreme cases, the exfoliation cause significant tube blockages that lead to forced power plant outages. It is thus desired to predict through modeling the propensity of exfoliation events in order to inform power plant operators of possible tube blockages. SpallMap solves for the stress-strain equations in an axisymmetric geometry, tracking the stress/strain evolution during boiler operation including outages at one-location along a boiler tube and compares it with scale damage criteria represented by Armitt diagram. The SPALLMAP code contains modules developedmore » for oxide growth, stress analysis, and classical fracture mechanics correlations by taking into account the following phenomena and features, (a) Non-uniform thermal expansion coefficient of oxides and metal substrates, (b) Plant operation schedule with periodic alternate full-load and partial-load regimes, (c) axisymmetric formulation for cylindrical tubes, (d) Multiple oxide layers, (e) oxide-growth induced stresses, and (f) damage criteria from classical fracture mechanics. The computer program is written in FORTRAN90. Its modular structure was sought for allowing the best flexibility in updating the program by implementing new constitutive equations due to availability of new material property data and/or new physical phenomena.« less

  17. Grid-connected photovoltaic (PV) systems with batteries storage as solution to electrical grid outages in Burkina Faso

    NASA Astrophysics Data System (ADS)

    Abdoulaye, D.; Koalaga, Z.; Zougmore, F.

    2012-02-01

    This paper deals with a key solution for power outages problem experienced by many African countries and this through grid-connected photovoltaic (PV) systems with batteries storage. African grids are characterized by an insufficient power supply and frequent interruptions. Due to this fact, users who especially use classical grid-connected photovoltaic systems are unable to profit from their installation even if there is sun. In this study, we suggest the using of a grid-connected photovoltaic system with batteries storage as a solution to these problems. This photovoltaic system works by injecting the surplus of electricity production into grid and can also deliver electricity as a stand-alone system with all security needed. To achieve our study objectives, firstly we conducted a survey of a real situation of one African electrical grid, the case of Burkina Faso (SONABEL: National Electricity Company of Burkina). Secondly, as study case, we undertake a sizing, a modeling and a simulation of a grid-connected PV system with batteries storage for the LAME laboratory at the University of Ouagadougou. The simulation shows that the proposed grid-connected system allows users to profit from their photovoltaic installation at any time even if the public electrical grid has some failures either during the day or at night.

  18. The human side of Hurricane Andrew

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, R.; Callander, R.C.

    1994-12-31

    This paper examines the long-term psychological effects of the nation`s worst natural disaster on the employees of the Turkey Point nuclear power plant. It also examines the efforts made by plant personnel and company volunteers to aid employees` families affected by the storm. Despite significant damage at the plant, unit 4 was returned to service 5 weeks after the August 24, 1992, hurricane. Unit 3 was returned to service on December 3, 1992. Unit 3 was originally scheduled to start a refueling outage the day Hurricane Andrew struck. While plant personnel are still recovering from Andrew`s impact, the plant`s performancemore » has never been better. On May 26, 1993, the plant completed a record-breaking 46-day refueling outage - 7 days ahead of schedule and $3 million under budget. Turkey Point`s recovery, return to service, and superior performance would not have been possible without the efforts of hundreds of employees who put their personal tragedies aside and focused on the common goal of the plant`s operation. To help employees with rebuilding their lives, the plant launched extensive assistance programs. Although the plant returned to normal operation, plant personnel continue to struggle in a community whose infrastructure (homes, schools, stores, etc.) have been almost eliminated.« less

  19. NASCOM network: Ground communications reliability report

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A reliability performance analysis of the NASCOM Network circuits is reported. Network performance narrative summary is presented to include significant changes in circuit configurations, current figures, and trends in each trouble category with notable circuit totals specified. Lost time and interruption tables listing circuits which were affected by outages showing their totals category are submitted. A special analysis of circuits with low reliabilities is developed with tables depicting the performance and graphs for individual reliabilities.

  20. A Next Generation Repository for Sharing Sensitive Network and Security Data

    DTIC Science & Technology

    2018-01-01

    submission, and 5 yearly IRB reviews d. Provided legal support for MOA data provider and host agreements and amendments e. Feedback and bug reporting...intrusion detection methods and systems , b) event- reconstruction and evidence-based insights into global trends (e.g., DDoS attacks and malware...propagation), and c) situational awareness (e.g., outage detection). We have leveraged IMPACT’s policy and legal framework to minimize any risks associated

  1. Communications/Navigation Outage Forecasting System (C/NOFS)

    DTIC Science & Technology

    2010-02-21

    al., 2002]. They are also lower than values predicted by the International Reference Iono- sphere ( IRI ) model [Gulyaeva and Titheridge, 2006] run for...based on the IRI model or other observations. At present no mechanism has been proposed which accounts for the basic formation of BPDs or their...funding by the DMSP program office. We thank J. Retterer for the IRI model results. This research was supported by Air Force Office of Scientific Research

  2. 49 CFR Appendix A to Part 179 - Procedures for Tank-Head Puncture-Resistance Test

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... outage with internal pressure of at least 6.9 Bar (100 psig) and coupled to one or more “backup” cars... the ram car. One test must be conducted with the coupler at a height of 53.3 cm (21 inches), plus-or... height at 79 cm (31 inches), plus-or-minus 2.5 cm (1 inch), above the top of the sill. If the combined...

  3. Demonstration of a Novel Synchrophasor-based Situational Awareness System: Wide Area Power System Visualization, On-line Event Replay and Early Warning of Grid Problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosso, A.

    Since the large North Eastern power system blackout on August 14, 2003, U.S. electric utilities have spent lot of effort on preventing power system cascading outages. Two of the main causes of the August 14, 2003 blackout were inadequate situational awareness and inadequate operator training In addition to the enhancements of the infrastructure of the interconnected power systems, more research and development of advanced power system applications are required for improving the wide-area security monitoring, operation and planning in order to prevent large- scale cascading outages of interconnected power systems. It is critically important for improving the wide-area situation awarenessmore » of the operators or operational engineers and regional reliability coordinators of large interconnected systems. With the installation of large number of phasor measurement units (PMU) and the related communication infrastructure, it will be possible to improve the operators’ situation awareness and to quickly identify the sequence of events during a large system disturbance for the post-event analysis using the real-time or historical synchrophasor data. The purpose of this project was to develop and demonstrate a novel synchrophasor-based comprehensive situational awareness system for control centers of power transmission systems. The developed system named WASA (Wide Area Situation Awareness) is intended to improve situational awareness at control centers of the power system operators and regional reliability coordinators. It consists of following main software modules: • Wide-area visualizations of real-time frequency, voltage, and phase angle measurements and their contour displays for security monitoring. • Online detection and location of a major event (location, time, size, and type, such as generator or line outage). • Near-real-time event replay (in seconds) after a major event occurs. • Early warning of potential wide-area stability problems. The system has been deployed and demonstrated at the Tennessee Valley Authority (TVA) and ISO New England system using real-time synchrophasor data from openPDC. Apart from the software product, the outcome of this project consists of a set of technical reports and papers describing the mathematical foundations and computational approaches of different tools and modules, implementation issues and considerations, lessons learned, and the results of lidation processes.« less

  4. Application of SAW method for multiple-criteria comparative analysis of the reliability of heat supply organizations

    NASA Astrophysics Data System (ADS)

    Akhmetova, I. G.; Chichirova, N. D.

    2016-12-01

    Heat supply is the most energy-consuming sector of the economy. Approximately 30% of all used primary fuel-and-energy resources is spent on municipal heat-supply needs. One of the key indicators of activity of heat-supply organizations is the reliability of an energy facility. The reliability index of a heat supply organization is of interest to potential investors for assessing risks when investing in projects. The reliability indices established by the federal legislation are actually reduced to a single numerical factor, which depends on the number of heat-supply outages in connection with disturbances in operation of heat networks and the volume of their resource recovery in the calculation year. This factor is rather subjective and may change in a wide range during several years. A technique is proposed for evaluating the reliability of heat-supply organizations with the use of the simple additive weighting (SAW) method. The technique for integrated-index determination satisfies the following conditions: the reliability level of the evaluated heat-supply system is represented maximum fully and objectively; the information used for the reliability-index evaluation is easily available (is located on the Internet in accordance with demands of data-disclosure standards). For reliability estimation of heat-supply organizations, the following indicators were selected: the wear of equipment of thermal energy sources, the wear of heat networks, the number of outages of supply of thermal energy (heat carrier due to technological disturbances on heat networks per 1 km of heat networks), the number of outages of supply of thermal energy (heat carrier due to technologic disturbances on thermal energy sources per 1 Gcal/h of installed power), the share of expenditures in the cost of thermal energy aimed at recovery of the resource (renewal of fixed assets), coefficient of renewal of fixed assets, and a coefficient of fixed asset retirement. A versatile program is developed and the analysis of heat-supply organizations is performed by the example of the Republic of Tatarstan. The assessment system is based on construction of comparative ratings of heat-supply organizations. A rating is the assessment of reliability of the organization, is characterized by a numerical value, and makes it possible to compare organizations engaged in the same kind of activity between each other.

  5. Collocated tunable wavenumber sensor/actuators for smart structures

    NASA Astrophysics Data System (ADS)

    Jones, Lori

    1994-02-01

    Two actuator modules have just come out of burnout. This burnout took longer than anticipated due to power outages during January. The measurements on the smaller actuators have been repeated and agreed with the previously reported values within +/- 10%. Measurements made on a glued stack showed stiffening with increasing stress from a modulus of about 4 Mpsi at 1000 psi to 12 Mpsi at 10,000 psi applied stress -- this shows the advantage of the cofired actuator.

  6. NOAA Weather Radio

    Science.gov Websites

    Programación Español Listado de estación Explicacion de SAME Coverage Station Listing County Listing Search For Go NWS All NOAA Lista de Emisora y Cobertura Seleccione aquí para radiofrecuencias (La lista Transmitter Outages FAQ NWR - Special Needs ESPAÑOL Español Condado de cobertura Listado de estación Lista

  7. Data-Logger Interface And Test Controller

    NASA Technical Reports Server (NTRS)

    Burch, Donnie R.

    1995-01-01

    Data-logger interface and test controller developed to enable automation of tests in conjunction with data-acquisition functions performed by data loggers that have output-switching capabilities. Includes relay logic circuits that remain deenergized until out-of-tolerance condition on any data channel discovered. Designed to be connected to Fluke model 2286A (or equivalent) data-logger system, which features 3 control channels with 6 data inputs per channel. Includes elapsed-time counter that keeps track of power outages.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdullayev, A. M.; Kulish, G. V.; Slyeptsov, O.

    The evaluation of WWER-1000 Westinghouse fuel performance was done using the results of post–irradiation examinations of six LTAs and the WFA reload batches that have operated normally in mixed cores at South-Ukraine NPP, Unit-3 and Unit-2. The data on WFA/LTA elongation, FR growth and bow, WFA bow and twist, RCCA drag force and drag work, RCCA drop time, FR cladding integrity as well as the visual observation of fuel assemblies obtained during the 2006-2012 outages was utilized. The analysis of the measured data showed that assembly growth, FR bow, irradiation growth, and Zr-1%Nb grid and ZIRLO cladding corrosion lies withinmore » the design limits. The RCCA drop time measured for the LTA/WFA is about 1.9 s at BOC and practically does not change at EOC. The measured WFA bow and twist, and data of drag work on RCCA insertion showed that the WFA deformation in the mixed core is mostly controlled by the distortion of Russian FAs (TVSA) having the higher lateral stiffness. The visual inspection of WFAs carried out during the 2012 outages revealed some damage to the Zr-1%Nb grid outer strap for some WFAs during the loading sequence. The performed fundamental investigations allowed identifying the root cause of grid outer strap deformation and proposing the WFA design modifications for preventing damage to SG at a 225 kg handling trip limit.« less

  9. Mission Support for the Communication/Navigation Outage Forecast System (C/NOFS) Satellite

    DTIC Science & Technology

    2007-11-21

    THE ABOVE ADDRESS. 1 . REPORT DATE (DO-MM-YYY 2. REPORT TYPE 3. DATES COVERED (From - To) 21-11-2007 Final Report Sept 2006 - Sept 2007 4. TITLE AND...298 (Rev. 8-98) P bWVANWS t. 2.$ Contents 1 . INTRODUCTION 2. METHODS AND PROCEDURES 1 3. FINDINGS 2 4. BIBLIOGRAPHY 15 ii List of Figures 1 . Six...entropy. The dashed line is the true model ............................................... 13 v 1 . INTRODUCTION This is a project to provide mission

  10. Opportunistic Beamforming with Wireless Powered 1-bit Feedback Through Rectenna Array

    NASA Astrophysics Data System (ADS)

    Krikidis, Ioannis

    2015-11-01

    This letter deals with the opportunistic beamforming (OBF) scheme for multi-antenna downlink with spatial randomness. In contrast to conventional OBF, the terminals return only 1-bit feedback, which is powered by wireless power transfer through a rectenna array. We study two fundamental topologies for the combination of the rectenna elements; the direct-current combiner and the radio-frequency combiner. The beam outage probability is derived in closed form for both combination schemes, by using high order statistics and stochastic geometry.

  11. Diagnostics of heavy mining equipment during the scheduled preventive maintenance

    NASA Astrophysics Data System (ADS)

    Drygin, M. Yu; Kuryshkin, N. P.

    2018-01-01

    Intensification of production, economic globalization and dramatic downgrade of the workers’ professional skills lead to unacceptable technical state of heavy mining equipment. Equipment maintenance outage reaches 84 % of the total downtime, of which emergency maintenance takes up to 36 % of time, that excesses 429 hours per year fr one excavator. It is shown that yearly diagnostics using methods of non-destructive check allows to reduce emergency downtime by 47 %, and 55 % of revealed defects can be eliminated without breaking the technological cycle of the equipment.

  12. Applicability of Firecracker Welding to Ship Production

    DTIC Science & Technology

    1975-07-31

    minor arc-outages seemed to coincide with defects in-the weld. For example, careful study of the film permitted orientation of such phenomena with the...Sample Electrode Electrode Voltage Current Frames Length weld covered No. Type diam. in. v A per sec. of film ft. in. Polarity 50 7024 1/4 35 240 128...to snuff out the arc. This was especially evident with the E7016 and E7018 electrodes which have a very fluid slag. The molten metal often caused a

  13. Electric Power Consumption Coefficients for U.S. Industries: Regional Estimation and Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boero, Riccardo

    Economic activity relies on electric power provided by electrical generation, transmission, and distribution systems. This paper presents a method developed at Los Alamos National Laboratory to estimate electric power consumption by different industries in the United States. Results are validated through comparisons with existing literature and benchmarking data sources. We also discuss the limitations and applications of the presented method, such as estimating indirect electric power consumption and assessing the economic impact of power outages based on input-output economic models.

  14. NOAA Weather Radio - Using NWR SAME

    Science.gov Websites

    Programación Español Listado de estación Explicacion de SAME Coverage Station Listing County Listing Transmitter Outages FAQ NWR - Special Needs ESPAÑOL Español Condado de cobertura Listado de estación Lista de Emisora y Cobertura Acerca de NWR ESTACIONES NACIONAL Información General Información Para el

  15. NOAA Weather Radio - Outage Reporting

    Science.gov Websites

    Programación Español Listado de estación Explicacion de SAME Coverage Station Listing County Listing ±ol Condado de cobertura Listado de estación Lista de Emisora y Cobertura Acerca de NWR ESTACIONES NACIONAL Información General Información Para el consumidor receptor NWR Recepción Explicacion de NWR

  16. NOAA Weather Radio - EAS Event Codes

    Science.gov Websites

    Programación Español Listado de estación Explicacion de SAME Coverage Station Listing County Listing Transmitter Outages FAQ NWR - Special Needs ESPAÑOL Español Condado de cobertura Listado de estación Lista de Emisora y Cobertura Acerca de NWR ESTACIONES NACIONAL Información General Información Para el

  17. NOAA Weather Radio - Station Listing

    Science.gov Websites

    Programación Español Listado de estación Explicacion de SAME Coverage Station Listing County Listing Outages FAQ NWR - Special Needs ESPAÑOL Español Condado de cobertura Listado de estación Lista de Emisora y Cobertura Acerca de NWR ESTACIONES NACIONAL Información General Información Para el consumidor

  18. NOAA Weather Radio - NWR Voices

    Science.gov Websites

    Programación Español Listado de estación Explicacion de SAME Coverage Station Listing County Listing Transmitter Outages FAQ NWR - Special Needs ESPAÑOL Español Condado de cobertura Listado de estación Lista de Emisora y Cobertura Acerca de NWR ESTACIONES NACIONAL Información General Información Para el

  19. NUMBER AND TYPE OF OPERATING CYCLES FOR THE FFTF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyd, D. C.

    1969-05-15

    The choice of materials and other vessel design decisions necessary to provide the desired life expectancy for the FTR vessel are partially dependent upon estimates of the number and type of reactor shutdowns and startups which may be anticipated. Current estimates of these so-called "cycles" are given, including scram frequency, experimental outage frequency, standard shutdowns and startups, and rapid controlled shutdowns. Also discussed are abnormal heatup or cooldown, and tentative goals for temperature controls. MTR, ETR, and typical PRTR operating histories are tabulated.

  20. Defense Attache Saigon: RVNAF Final Assessment, 1 January thru 25 April FY 75,

    DTIC Science & Technology

    1975-06-15

    seven respective JGS/J6 operating divisions. The reorganization was effected on 1 March 1975. 4. SELECTED C-E EVALUATIONS: a. Undersea cable outage. (1...L.ehmann approved recomnendations concerning incre, ing tte alert status of the fleet and 7th AF troop carriers and holding 16-(:-2 FOR OFFICIAL USE ONLY...radio transmission system, .n’d all areas of SVN and interfaced with US undersea cables to Philippines and Thailand and with the US tropospheric scatter

  1. Sample EP Flow Analysis of Severely Damaged Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Werley, Kenneth Alan; McCown, Andrew William

    These are slides for a presentation at the working group meeting of the WESC SREMP Software Product Integration Team on sample EP flow analysis of severely damaged networks. The following topics are covered: ERCOT EP Transmission Model; Zoomed in to Houston and Overlaying StreetAtlas; EMPACT Solve/Dispatch/Shedding Options; QACS BaseCase Power Flow Solution; 3 Substation Contingency; Gen. & Load/100 Optimal Dispatch; Dispatch Results; Shed Load for Low V; Network Damage Summary; Estimated Service Areas (Potential); Estimated Outage Areas (potential).

  2. A Fire Department Community Health Intervention to Prevent Carbon Monoxide Poisoning Following a Hurricane

    PubMed Central

    Levy, Matthew; Jenkins, J Lee; Seaman, Kevin

    2014-01-01

    Portable generators are commonly used during electrical service interruptions that occur following large storms such as hurricanes. Nearly all portable generators use carbon based fuels and produce deadly carbon monoxide gas. Despite universal warnings to operate these generators outside only, the improper placement of generators makes these devices the leading cause of engine related carbon monoxide deaths in the United States. The medical literature reports many cases of Carbon Monoxide (CO) toxicity associated with generator use following hurricanes and other weather events. This paper describes how Howard County, Maryland Fire and Rescue (HCFR) Services implemented a public education program that focused on prevention of Carbon Monoxide poisoning from portable generator use in the wake of events where electrical service interruptions occurred or had the potential to occur. A major challenge faced was communication with those members of the population who were almost completely dependent upon electronic and wireless technologies and were without redundancies. HCFR utilized several tactics to overcome this challenge including helicopter based surveillance and the use of geocoded information from the electrical service provider to identify outage areas. Once outage areas were identified, HCFR personnel conducted a door-to-door canvasing of effected communities, assessing for hazards and distributing information flyers about the dangers of generator use. This effort represents one of the first reported examples of a community-based endeavor by a fire department to provide proactive interventions designed to prevent carbon monoxide illness. PMID:24596660

  3. Naturalistic Decision Making For Power System Operators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greitzer, Frank L.; Podmore, Robin; Robinson, Marck

    2009-06-23

    Abstract: Motivation -- As indicated by the Blackout of 2003, the North American interconnected electric system is vulnerable to cascading outages and widespread blackouts. Investigations of large scale outages often attribute the causes to the three T’s: Trees, Training and Tools. A systematic approach has been developed to document and understand the mental processes that an expert power system operator uses when making critical decisions. The approach has been developed and refined as part of a capability demonstration of a high-fidelity real-time power system simulator under normal and emergency conditions. To examine naturalistic decision making (NDM) processes, transcripts of operator-to-operatormore » conversations are analyzed to reveal and assess NDM-based performance criteria. Findings/Design -- The results of the study indicate that we can map the Situation Awareness Level of the operators at each point in the scenario. We can also identify clearly what mental models and mental simulations are being performed at different points in the scenario. As a result of this research we expect that we can identify improved training methods and improved analytical and visualization tools for power system operators. Originality/Value -- The research applies for the first time, the concepts of Recognition Primed Decision Making, Situation Awareness Levels and Cognitive Task Analysis to training of electric power system operators. Take away message -- The NDM approach provides an ideal framework for systematic training management and mitigation to accelerate learning in team-based training scenarios with high-fidelity power grid simulators.« less

  4. Autonomous Navigation of Small Uavs Based on Vehicle Dynamic Model

    NASA Astrophysics Data System (ADS)

    Khaghani, M.; Skaloud, J.

    2016-03-01

    This paper presents a novel approach to autonomous navigation for small UAVs, in which the vehicle dynamic model (VDM) serves as the main process model within the navigation filter. The proposed method significantly increases the accuracy and reliability of autonomous navigation, especially for small UAVs with low-cost IMUs on-board. This is achieved with no extra sensor added to the conventional INS/GNSS setup. This improvement is of special interest in case of GNSS outages, where inertial coasting drifts very quickly. In the proposed architecture, the solution to VDM equations provides the estimate of position, velocity, and attitude, which is updated within the navigation filter based on available observations, such as IMU data or GNSS measurements. The VDM is also fed with the control input to the UAV, which is available within the control/autopilot system. The filter is capable of estimating wind velocity and dynamic model parameters, in addition to navigation states and IMU sensor errors. Monte Carlo simulations reveal major improvements in navigation accuracy compared to conventional INS/GNSS navigation system during the autonomous phase, when satellite signals are not available due to physical obstruction or electromagnetic interference for example. In case of GNSS outages of a few minutes, position and attitude accuracy experiences improvements of orders of magnitude compared to inertial coasting. It means that during such scenario, the position-velocity-attitude (PVA) determination is sufficiently accurate to navigate the UAV to a home position without any signal that depends on vehicle environment.

  5. Outage Probability Minimization for Energy Harvesting Cognitive Radio Sensor Networks

    PubMed Central

    Zhang, Fan; Jing, Tao; Huo, Yan; Jiang, Kaiwei

    2017-01-01

    The incorporation of cognitive radio (CR) capability in wireless sensor networks yields a promising network paradigm known as CR sensor networks (CRSNs), which is able to provide spectrum efficient data communication. However, due to the high energy consumption results from spectrum sensing, as well as subsequent data transmission, the energy supply for the conventional sensor nodes powered by batteries is regarded as a severe bottleneck for sustainable operation. The energy harvesting technique, which gathers energy from the ambient environment, is regarded as a promising solution to perpetually power-up energy-limited devices with a continual source of energy. Therefore, applying the energy harvesting (EH) technique in CRSNs is able to facilitate the self-sustainability of the energy-limited sensors. The primary concern of this study is to design sensing-transmission policies to minimize the long-term outage probability of EH-powered CR sensor nodes. We formulate this problem as an infinite-horizon discounted Markov decision process and propose an ϵ-optimal sensing-transmission (ST) policy through using the value iteration algorithm. ϵ is the error bound between the ST policy and the optimal policy, which can be pre-defined according to the actual need. Moreover, for a special case that the signal-to-noise (SNR) power ratio is sufficiently high, we present an efficient transmission (ET) policy and prove that the ET policy achieves the same performance with the ST policy. Finally, extensive simulations are conducted to evaluate the performance of the proposed policies and the impaction of various network parameters. PMID:28125023

  6. Outage Probability Minimization for Energy Harvesting Cognitive Radio Sensor Networks.

    PubMed

    Zhang, Fan; Jing, Tao; Huo, Yan; Jiang, Kaiwei

    2017-01-24

    The incorporation of cognitive radio (CR) capability in wireless sensor networks yields a promising network paradigm known as CR sensor networks (CRSNs), which is able to provide spectrum efficient data communication. However, due to the high energy consumption results from spectrum sensing, as well as subsequent data transmission, the energy supply for the conventional sensor nodes powered by batteries is regarded as a severe bottleneck for sustainable operation. The energy harvesting technique, which gathers energy from the ambient environment, is regarded as a promising solution to perpetually power-up energy-limited devices with a continual source of energy. Therefore, applying the energy harvesting (EH) technique in CRSNs is able to facilitate the self-sustainability of the energy-limited sensors. The primary concern of this study is to design sensing-transmission policies to minimize the long-term outage probability of EH-powered CR sensor nodes. We formulate this problem as an infinite-horizon discounted Markov decision process and propose an ϵ -optimal sensing-transmission (ST) policy through using the value iteration algorithm. ϵ is the error bound between the ST policy and the optimal policy, which can be pre-defined according to the actual need. Moreover, for a special case that the signal-to-noise (SNR) power ratio is sufficiently high, we present an efficient transmission (ET) policy and prove that the ET policy achieves the same performance with the ST policy. Finally, extensive simulations are conducted to evaluate the performance of the proposed policies and the impaction of various network parameters.

  7. A Model for QoS – Aware Wireless Communication in Hospitals

    PubMed Central

    Alavikia, Zahra; Khadivi, Pejman; Hashemi, Masoud Reza

    2012-01-01

    In the recent decade, research regarding wireless applications in electronic health (e-Health) services has been increasing. The main benefits of using wireless technologies in e-Health applications are simple communications, fast delivery of medical information, reducing treatment cost and also reducing the medical workers’ error rate. However, using wireless communications in sensitive healthcare environment raises electromagnetic interference (EMI). One of the most effective methods to avoid the EMI problem is power management. To this end, some of methods have been proposed in the literature to reduce EMI effects in health care environments. However, using these methods may result in nonaccurate interference avoidance and also may increase network complexity. To overcome these problems, we introduce two approaches based on per-user location and hospital sectoring for power management in sensitive healthcare environments. Although reducing transmission power could avoid EMI, it causes a number of successful message deliveries to the access point to decrease and, hence, the quality of service requirements cannot be meet. In this paper, we propose the use of relays for decreasing the probability of outage in the aforementioned scenario. Relay placement is the main factor to enjoy the usefulness of relay station benefits in the network and, therefore, we use the genetic algorithm to compute the optimum positions of a fixed number of relays. We have considered delay and maximum blind point coverage as two main criteria in relay station problem. The performance of the proposed method in outage reduction is investigated through simulations. PMID:23493832

  8. A Model for QoS - Aware Wireless Communication in Hospitals.

    PubMed

    Alavikia, Zahra; Khadivi, Pejman; Hashemi, Masoud Reza

    2012-01-01

    In the recent decade, research regarding wireless applications in electronic health (e-Health) services has been increasing. The main benefits of using wireless technologies in e-Health applications are simple communications, fast delivery of medical information, reducing treatment cost and also reducing the medical workers' error rate. However, using wireless communications in sensitive healthcare environment raises electromagnetic interference (EMI). One of the most effective methods to avoid the EMI problem is power management. To this end, some of methods have been proposed in the literature to reduce EMI effects in health care environments. However, using these methods may result in nonaccurate interference avoidance and also may increase network complexity. To overcome these problems, we introduce two approaches based on per-user location and hospital sectoring for power management in sensitive healthcare environments. Although reducing transmission power could avoid EMI, it causes a number of successful message deliveries to the access point to decrease and, hence, the quality of service requirements cannot be meet. In this paper, we propose the use of relays for decreasing the probability of outage in the aforementioned scenario. Relay placement is the main factor to enjoy the usefulness of relay station benefits in the network and, therefore, we use the genetic algorithm to compute the optimum positions of a fixed number of relays. We have considered delay and maximum blind point coverage as two main criteria in relay station problem. The performance of the proposed method in outage reduction is investigated through simulations.

  9. Downlink Probability Density Functions for EOS-McMurdo Sound

    NASA Technical Reports Server (NTRS)

    Christopher, P.; Jackson, A. H.

    1996-01-01

    The visibility times and communication link dynamics for the Earth Observations Satellite (EOS)-McMurdo Sound direct downlinks have been studied. The 16 day EOS periodicity may be shown with the Goddard Trajectory Determination System (GTDS) and the entire 16 day period should be simulated for representative link statistics. We desire many attributes of the downlink, however, and a faster orbital determination method is desirable. We use the method of osculating elements for speed and accuracy in simulating the EOS orbit. The accuracy of the method of osculating elements is demonstrated by closely reproducing the observed 16 day Landsat periodicity. An autocorrelation function method is used to show the correlation spike at 16 days. The entire 16 day record of passes over McMurdo Sound is then used to generate statistics for innage time, outage time, elevation angle, antenna angle rates, and propagation loss. The levation angle probability density function is compared with 1967 analytic approximation which has been used for medium to high altitude satellites. One practical result of this comparison is seen to be the rare occurrence of zenith passes. The new result is functionally different than the earlier result, with a heavy emphasis on low elevation angles. EOS is one of a large class of sun synchronous satellites which may be downlinked to McMurdo Sound. We examine delay statistics for an entire group of sun synchronous satellites ranging from 400 km to 1000 km altitude. Outage probability density function results are presented three dimensionally.

  10. Optimization of replacement and inspection decisions for multiple components on a power system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mauney, D.A.

    1994-12-31

    The use of optimization on the rescheduling of replacement dates provided a very proactive approach to deciding when components on individual units need to be addressed with a run/repair/replace decision. Including the effects of time value of money and taxes and unit need inside the spreadsheet model allowed the decision maker to concentrate on the effects of engineering input and replacement date decisions on the final net present value (NPV). The personal computer (PC)-based model was applied to a group of 140 forced outage critical fossil plant tube components across a power system. The estimated resulting NPV of the optimizationmore » was in the tens of millions of dollars. This PC spreadsheet model allows the interaction of inputs from structural reliability risk assessment models, plant foreman interviews, and actual failure history on a by component by unit basis across a complete power production system. This model includes not only the forced outage performance of these components caused by tube failures but, in addition, the forecasted need of the individual units on the power system and the expected cost of their replacement power if forced off line. The use of cash flow analysis techniques in the spreadsheet model results in the calculation of an NPV for a whole combination of replacement dates. This allows rapid assessments of {open_quotes}what if{close_quotes} scenarios of major maintenance projects on a systemwide basis and not just on a unit-by-unit basis.« less

  11. A Three-Phase Microgrid Restoration Model Considering Unbalanced Operation of Distributed Generation

    DOE PAGES

    Wang, Zeyu; Wang, Jianhui; Chen, Chen

    2016-12-07

    Recent severe outages highlight the urgency of improving grid resiliency in the U.S. Microgrid formation schemes are proposed to restore critical loads after outages occur. Most distribution networks have unbalanced configurations that are not represented in sufficient detail by single-phase models. This study provides a microgrid formation plan that adopts a three-phase network model to represent unbalanced distribution networks. The problem formulation has a quadratic objective function with mixed-integer linear constraints. The three-phase network model enables us to examine the three-phase power outputs of distributed generators (DGs), preventing unbalanced operation that might trip DGs. Because the DG unbalanced operation constraintmore » is non-convex, an iterative process is presented that checks whether the unbalanced operation limits for DGs are satisfied after each iteration of optimization. We also develop a relatively conservative linear approximation on the unbalanced operation constraint to handle larger networks. Compared with the iterative solution process, the conservative linear approximation is able to accelerate the solution process at the cost of sacrificing optimality to a limited extent. Simulation in the IEEE 34 node and IEEE 123 test feeders indicate that the proposed method yields more practical microgrid formations results. In addition, this paper explores the coordinated operation of DGs and energy storage (ES) installations. The unbalanced three-phase outputs of ESs combined with the relatively balanced outputs of DGs could supply unbalanced loads. In conclusion, the case study also validates the DG-ES coordination.« less

  12. A Three-Phase Microgrid Restoration Model Considering Unbalanced Operation of Distributed Generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zeyu; Wang, Jianhui; Chen, Chen

    Recent severe outages highlight the urgency of improving grid resiliency in the U.S. Microgrid formation schemes are proposed to restore critical loads after outages occur. Most distribution networks have unbalanced configurations that are not represented in sufficient detail by single-phase models. This study provides a microgrid formation plan that adopts a three-phase network model to represent unbalanced distribution networks. The problem formulation has a quadratic objective function with mixed-integer linear constraints. The three-phase network model enables us to examine the three-phase power outputs of distributed generators (DGs), preventing unbalanced operation that might trip DGs. Because the DG unbalanced operation constraintmore » is non-convex, an iterative process is presented that checks whether the unbalanced operation limits for DGs are satisfied after each iteration of optimization. We also develop a relatively conservative linear approximation on the unbalanced operation constraint to handle larger networks. Compared with the iterative solution process, the conservative linear approximation is able to accelerate the solution process at the cost of sacrificing optimality to a limited extent. Simulation in the IEEE 34 node and IEEE 123 test feeders indicate that the proposed method yields more practical microgrid formations results. In addition, this paper explores the coordinated operation of DGs and energy storage (ES) installations. The unbalanced three-phase outputs of ESs combined with the relatively balanced outputs of DGs could supply unbalanced loads. In conclusion, the case study also validates the DG-ES coordination.« less

  13. Risk prediction of Critical Infrastructures against extreme natural hazards: local and regional scale analysis

    NASA Astrophysics Data System (ADS)

    Rosato, Vittorio; Hounjet, Micheline; Burzel, Andreas; Di Pietro, Antonio; Tofani, Alberto; Pollino, Maurizio; Giovinazzi, Sonia

    2016-04-01

    Natural hazard events can induce severe impacts on the built environment; they can hit wide and densely populated areas, where there is a large number of (inter)dependent technological systems whose damages could cause the failure or malfunctioning of further different services, spreading the impacts on wider geographical areas. The EU project CIPRNet (Critical Infrastructures Preparedness and Resilience Research Network) is realizing an unprecedented Decision Support System (DSS) which enables to operationally perform risk prediction on Critical Infrastructures (CI) by predicting the occurrence of natural events (from long term weather to short nowcast predictions, correlating intrinsic vulnerabilities of CI elements with the different events' manifestation strengths, and analysing the resulting Damage Scenario. The Damage Scenario is then transformed into an Impact Scenario, where punctual CI element damages are transformed into micro (local area) or meso (regional) scale Services Outages. At the smaller scale, the DSS simulates detailed city models (where CI dependencies are explicitly accounted for) that are of important input for crisis management organizations whereas, at the regional scale by using approximate System-of-Systems model describing systemic interactions, the focus is on raising awareness. The DSS has allowed to develop a novel simulation framework for predicting earthquakes shake maps originating from a given seismic event, considering the shock wave propagation in inhomogeneous media and the subsequent produced damages by estimating building vulnerabilities on the basis of a phenomenological model [1, 2]. Moreover, in presence of areas containing river basins, when abundant precipitations are expected, the DSS solves the hydrodynamic 1D/2D models of the river basins for predicting the flux runoff and the corresponding flood dynamics. This calculation allows the estimation of the Damage Scenario and triggers the evaluation of the Impact Scenario. The regional output of cascading effects can be used as an input model for more detailed analyses within urban areas for instance. The DSS weights the overall expected Crisis Scenario by also considering, through an appropriate Consequences Analysis, the number of citizens affected by the Service(s) outages, the expected economic losses of the major industrial activities hit by the unavailability of relevant Services (electricity, water, telecommunications etc.) and the influence of outages of the availability of Public Services (hospitals, schools, public offices etc.) [1] S.Giovinazzi, S. Lagomarsino: A macroseismic method for the vulnerability assessment of buildings. 13th World Conference on Earthquake Engineering, Vancouver, BC, Canada (2004) [2] S. Lagomarsino, S.Giovinazzi: Macroseismic and mechanical models for the vulnerability and damage assessment of current buildings. Bull Earthquake Eng., 4:415-443 (2006)

  14. Guest Editor's Introduction: Special section on dependable distributed systems

    NASA Astrophysics Data System (ADS)

    Fetzer, Christof

    1999-09-01

    We rely more and more on computers. For example, the Internet reshapes the way we do business. A `computer outage' can cost a company a substantial amount of money. Not only with respect to the business lost during an outage, but also with respect to the negative publicity the company receives. This is especially true for Internet companies. After recent computer outages of Internet companies, we have seen a drastic fall of the shares of the affected companies. There are multiple causes for computer outages. Although computer hardware becomes more reliable, hardware related outages remain an important issue. For example, some of the recent computer outages of companies were caused by failed memory and system boards, and even by crashed disks - a failure type which can easily be masked using disk mirroring. Transient hardware failures might also look like software failures and, hence, might be incorrectly classified as such. However, many outages are software related. Faulty system software, middleware, and application software can crash a system. Dependable computing systems are systems we can rely on. Dependable systems are, by definition, reliable, available, safe and secure [3]. This special section focuses on issues related to dependable distributed systems. Distributed systems have the potential to be more dependable than a single computer because the probability that all computers in a distributed system fail is smaller than the probability that a single computer fails. However, if a distributed system is not built well, it is potentially less dependable than a single computer since the probability that at least one computer in a distributed system fails is higher than the probability that one computer fails. For example, if the crash of any computer in a distributed system can bring the complete system to a halt, the system is less dependable than a single-computer system. Building dependable distributed systems is an extremely difficult task. There is no silver bullet solution. Instead one has to apply a variety of engineering techniques [2]: fault-avoidance (minimize the occurrence of faults, e.g. by using a proper design process), fault-removal (remove faults before they occur, e.g. by testing), fault-evasion (predict faults by monitoring and reconfigure the system before failures occur), and fault-tolerance (mask and/or contain failures). Building a system from scratch is an expensive and time consuming effort. To reduce the cost of building dependable distributed systems, one would choose to use commercial off-the-shelf (COTS) components whenever possible. The usage of COTS components has several potential advantages beyond minimizing costs. For example, through the widespread usage of a COTS component, design failures might be detected and fixed before the component is used in a dependable system. Custom-designed components have to mature without the widespread in-field testing of COTS components. COTS components have various potential disadvantages when used in dependable systems. For example, minimizing the time to market might lead to the release of components with inherent design faults (e.g. use of `shortcuts' that only work most of the time). In addition, the components might be more complex than needed and, hence, potentially have more design faults than simpler components. However, given economic constraints and the ability to cope with some of the problems using fault-evasion and fault-tolerance, only for a small percentage of systems can one justify not using COTS components. Distributed systems built from current COTS components are asynchronous systems in the sense that there exists no a priori known bound on the transmission delay of messages or the execution time of processes. When designing a distributed algorithm, one would like to make sure (e.g. by testing or verification) that it is correct, i.e. satisfies its specification. Many distributed algorithms make use of consensus (eventually all non-crashed processes have to agree on a value), leader election (a crashed leader is eventually replaced by a new leader, but at any time there is at most one leader) or a group membership detection service (a crashed process is eventually suspected to have crashed but only crashed processes are suspected). From a theoretical point of view, the service specifications given for such services are not implementable in asynchronous systems. In particular, for each implementation one can derive a counter example in which the service violates its specification. From a practical point of view, the consensus, the leader election, and the membership detection problem are solvable in asynchronous distributed systems. In this special section, Raynal and Tronel show how to bridge this difference by showing how to implement the group membership detection problem with a negligible probability [1] to fail in an asynchronous system. The group membership detection problem is specified by a liveness condition (L) and a safety property (S): (L) if a process p crashes, then eventually every non-crashed process q has to suspect that p has crashed; and (S) if a process q suspects p, then p has indeed crashed. One can show that either (L) or (S) is implementable, but one cannot implement both (L) and (S) at the same time in an asynchronous system. In practice, one only needs to implement (L) and (S) such that the probability that (L) or (S) is violated becomes negligible. Raynal and Tronel propose and analyse a protocol that implements (L) with certainty and that can be tuned such that the probability that (S) is violated becomes negligible. Designing and implementing distributed fault-tolerant protocols for asynchronous systems is a difficult but not an impossible task. A fault-tolerant protocol has to detect and mask certain failure classes, e.g. crash failures and message omission failures. There is a trade-off between the performance of a fault-tolerant protocol and the failure classes the protocol can tolerate. One wants to tolerate as many failure classes as needed to satisfy the stochastic requirements of the protocol [1] while still maintaining a sufficient performance. Since clients of a protocol have different requirements with respect to the performance/fault-tolerance trade-off, one would like to be able to customize protocols such that one can select an appropriate performance/fault-tolerance trade-off. In this special section Hiltunen et al describe how one can compose protocols from micro-protocols in their Cactus system. They show how a group RPC system can be tailored to the needs of a client. In particular, they show how considering additional failure classes affects the performance of a group RPC system. References [1] Cristian F 1991 Understanding fault-tolerant distributed systems Communications of ACM 34 (2) 56-78 [2] Heimerdinger W L and Weinstock C B 1992 A conceptual framework for system fault tolerance Technical Report 92-TR-33, CMU/SEI [3] Laprie J C (ed) 1992 Dependability: Basic Concepts and Terminology (Vienna: Springer)

  15. Performance Analysis of Constrained Loosely Coupled GPS/INS Integration Solutions

    PubMed Central

    Falco, Gianluca; Einicke, Garry A.; Malos, John T.; Dovis, Fabio

    2012-01-01

    The paper investigates approaches for loosely coupled GPS/INS integration. Error performance is calculated using a reference trajectory. A performance improvement can be obtained by exploiting additional map information (for example, a road boundary). A constrained solution has been developed and its performance compared with an unconstrained one. The case of GPS outages is also investigated showing how a Kalman filter that operates on the last received GPS position and velocity measurements provides a performance benefit. Results are obtained by means of simulation studies and real data. PMID:23202241

  16. Diversity Order Analysis of Dual-Hop Relaying with Partial Relay Selection

    NASA Astrophysics Data System (ADS)

    Bao, Vo Nguyen Quoc; Kong, Hyung Yun

    In this paper, we study the performance of dual hop relaying in which the best relay selected by partial relay selection will help the source-destination link to overcome the channel impairment. Specifically, closed-form expressions for outage probability, symbol error probability and achievable diversity gain are derived using the statistical characteristic of the signal-to-noise ratio. Numerical investigation shows that the system achieves diversity of two regardless of relay number and also confirms the correctness of the analytical results. Furthermore, the performance loss due to partial relay selection is investigated.

  17. NOAA Weather Radio - Viewing Outages

    Science.gov Websites

    Programación Español Listado de estación Explicacion de SAME Coverage Station Listing County Listing Listado de estación Lista de Emisora y Cobertura Acerca de NWR ESTACIONES NACIONAL Información General Información Para el consumidor receptor NWR Recepción Explicacion de NWR SAME Programación en Español

  18. Hazards of geomagnetic storms

    USGS Publications Warehouse

    Herzog, D.C.

    1992-01-01

    Geomagnetic storms are large and sometimes rapid fluctuations in the Earth's magnetic field that are related to disturbances on the Sun's surface. Although it is not widely recognized, these transient magnetic disturbances can be a significant hazard to people and property. Many of us know that the intensity of the auroral lights increases during magnetic storms, but few people realize that these storms can also cause massive power outages, interrupt radio communications and satellite operations, increase corrosion in oil and gas pipelines, and lead to spuriously high rejection rates in the manufacture of sensitive electronic equipment. 

  19. Emergency Lighting System

    NASA Technical Reports Server (NTRS)

    1994-01-01

    When power outages occurred at Landmark Plastic Corporation, it took seven to twelve minutes for the primary mercury lamps to cool down enough to relight and two to seven minutes for the ELS incandescent lamps to relight. Production could not resume for as much as seven minutes. An article in NASA Tech Briefs describing the capabilities of photosensing devices led Landmark employee, Steve Keller to design a system now activated by any voltage loss in the main lamp circuit and coupled with photosensing devices used to keep them on until the primary mercury lamps reach full brightness.

  20. Detection of Ionospheric Alfven Resonator Signatures in the Equatorial Ionosphere

    NASA Technical Reports Server (NTRS)

    Simoes, Fernando; Klenzing, Jeffrey; Ivanov, Stoyan; Pfaff, Robert; Freudenreich, Henry; Bilitza, Dieter; Rowland, Douglas; Bromund, Kenneth; Liebrecht, Maria Carmen; Martin, Steven; hide

    2012-01-01

    The ionosphere response resulting from minimum solar activity during cycle 23/24 was unusual and offered unique opportunities for investigating space weather in the near-Earth environment. We report ultra low frequency electric field signatures related to the ionospheric Alfven resonator detected by the Communications/Navigation Outage Forecasting System (C/NOFS) satellite in the equatorial region. These signatures are used to constrain ionospheric empirical models and offer a new approach for monitoring ionosphere dynamics and space weather phenomena, namely aeronomy processes, Alfven wave propagation, and troposphere24 ionosphere-magnetosphere coupling mechanisms.

  1. REopt Lite Web Tool Evaluates Photovoltaics and Battery Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Building on the success of the REopt renewable energy integration and optimization platform, NREL has developed a free, publicly available web version of REopt called REopt Lite. REopt Lite evaluates the economics of grid-connected photovoltaics (PV) and battery storage at a site. It allows building owners to identify the system sizes and battery dispatch strategy that minimize their life cycle cost of energy. This web tool also estimates the amount of time a PV and storage system can sustain the site's critical load during a grid outage.

  2. QUAD+ BWR Fuel Assembly demonstration program at Browns Ferry plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doshi, P.K.; Mayhue, L.T.; Robert, J.T.

    1984-04-01

    The QUAD+ fuel assembly is an improved BWR fuel assembly designed and manufactured by Westinghouse Electric Corporation. The design features a water cross separating four fuel minibundles in an integral channel. A demonstration program for this fuel design is planned for late 1984 in cycle 6 of Browns Ferry 2, a TVA plant. Objectives for the design of the QUAD+ demonstration assemblies are compatibility in performance and transparency in safety analysis with the feed fuel. These objectives are met. Inspections of the QUAD+ demonstration assemblies are planned at each refueling outage.

  3. Secure Multiuser Communications in Wireless Sensor Networks with TAS and Cooperative Jamming

    PubMed Central

    Yang, Maoqiang; Zhang, Bangning; Huang, Yuzhen; Yang, Nan; Guo, Daoxing; Gao, Bin

    2016-01-01

    In this paper, we investigate the secure transmission in wireless sensor networks (WSNs) consisting of one multiple-antenna base station (BS), multiple single-antenna legitimate users, one single-antenna eavesdropper and one multiple-antenna cooperative jammer. In an effort to reduce the scheduling complexity and extend the battery lifetime of the sensor nodes, the switch-and-stay combining (SSC) scheduling scheme is exploited over the sensor nodes. Meanwhile, transmit antenna selection (TAS) is employed at the BS and cooperative jamming (CJ) is adopted at the jammer node, aiming at achieving a satisfactory secrecy performance. Moreover, depending on whether the jammer node has the global channel state information (CSI) of both the legitimate channel and the eavesdropper’s channel, it explores a zero-forcing beamforming (ZFB) scheme or a null-space artificial noise (NAN) scheme to confound the eavesdropper while avoiding the interference to the legitimate user. Building on this, we propose two novel hybrid secure transmission schemes, termed TAS-SSC-ZFB and TAS-SSC-NAN, for WSNs. We then derive the exact closed-form expressions for the secrecy outage probability and the effective secrecy throughput of both schemes to characterize the secrecy performance. Using these closed-form expressions, we further determine the optimal switching threshold and obtain the optimal power allocation factor between the BS and jammer node for both schemes to minimize the secrecy outage probability, while the optimal secrecy rate is decided to maximize the effective secrecy throughput for both schemes. Numerical results are provided to verify the theoretical analysis and illustrate the impact of key system parameters on the secrecy performance. PMID:27845753

  4. A piezoelectric brace for passive suppression of structural vibration and energy harvesting

    NASA Astrophysics Data System (ADS)

    Yang, Chuang-Sheng Walter; Lai, Yong-An; Kim, Jin-Yeon

    2017-08-01

    Power outage after an earthquake would cause an additional chaos to the existing aftermath, greatly aggravating the situation if the outage lasts for an extended period. This research aims at developing an innovative piezoelectric brace, which provides both passive energy-dissipating and energy-harvesting capabilities—a passive suppression of structural vibrations and conversion of vibration energy into reusable electricity. The piezoelectric brace has compression modules that exert compressive loads on the piezoelectric material regardless if the brace is in compression or in tension. The compression module consists of a piezoelectric stack and rubber pads. The rubber pads are used to limit the maximum strain in the piezoelectric material below the allowable operational strain. The electro-mechanical equations of motion are derived for a 1-story and a 3-story frame model with the piezoelectric braces. To evaluate the structural behavior and the energy harvesting performance, numerical simulations are executed for the two model buildings (in downtown Los Angeles) that are equipped with the piezoelectric braces. The effects of design parameters including the geometry of the piezoelectric stack and rubber pads and the electric resistance in the electro-mechanical conversion circuit on the performance are investigated. The numerical results indicate that the piezoelectric braces passively dissipate energy through inclined oval-shaped hysteretic loops. The harvested energy is up to approximately 40% of the input energy. The structural displacements are significantly reduced, as compared to the original frames without the piezoelectric braces. Finally, a design procedure for a frame with the proposed passive piezoelectric braces is also presented.

  5. VORBrouter: A dynamic data routing system for Real-Time Seismic networks

    NASA Astrophysics Data System (ADS)

    Hansen, T.; Vernon, F.; Lindquist, K.; Orcutt, J.

    2004-12-01

    For anyone who has managed a moderately complex buffered real-time data transport system, the need for reliable adaptive data transport is clear. The ROADNet VORBrouter system, an extension to the ROADNet data catalog system [AGU-2003, Dynamic Dataflow Topology Monitoring for Real-time Seismic Networks], allows dynamic routing of real-time seismic data from sensor to end-user. Traditional networks consist of a series of data buffer computers with data transport interconnections configured by hand. This allows for arbitrarily complex data networks, which can often exceed full comprehension by network administrators, sometimes resulting in data loops or accidental data cutoff. In order to manage data transport systems in the event of a network failure, a network administrator must be called upon to change the data transport paths and to recover the missing data. Using VORBrouter, administrators can sleep at night while still providing 7/24 uninterupted data streams at realistic cost. This software package uses information from the ROADNet data catalog system to route packets around failed link outages and to new consumers in real-time. Dynamic data routing protocols operating on top of the Antelope Data buffering layer allow authorized users to request data sets from their local buffer and to have them delivered from anywhere within the network of buffers. The VORBrouter software also allows for dynamic routing around network outages, and the elimination of duplicate data paths within the network, while maintaining the nearly lossless data transport features exhibited by the underlying Antelope system. We present the design of the VORBrouter system, its features, limitations and some future research directions.

  6. Automating usability of ATLAS Distributed Computing resources

    NASA Astrophysics Data System (ADS)

    Tupputi, S. A.; Di Girolamo, A.; Kouba, T.; Schovancová, J.; Atlas Collaboration

    2014-06-01

    The automation of ATLAS Distributed Computing (ADC) operations is essential to reduce manpower costs and allow performance-enhancing actions, which improve the reliability of the system. In this perspective a crucial case is the automatic handling of outages of ATLAS computing sites storage resources, which are continuously exploited at the edge of their capabilities. It is challenging to adopt unambiguous decision criteria for storage resources of non-homogeneous types, sizes and roles. The recently developed Storage Area Automatic Blacklisting (SAAB) tool has provided a suitable solution, by employing an inference algorithm which processes history of storage monitoring tests outcome. SAAB accomplishes both the tasks of providing global monitoring as well as automatic operations on single sites. The implementation of the SAAB tool has been the first step in a comprehensive review of the storage areas monitoring and central management at all levels. Such review has involved the reordering and optimization of SAM tests deployment and the inclusion of SAAB results in the ATLAS Site Status Board with both dedicated metrics and views. The resulting structure allows monitoring the storage resources status with fine time-granularity and automatic actions to be taken in foreseen cases, like automatic outage handling and notifications to sites. Hence, the human actions are restricted to reporting and following up problems, where and when needed. In this work we show SAAB working principles and features. We present also the decrease of human interactions achieved within the ATLAS Computing Operation team. The automation results in a prompt reaction to failures, which leads to the optimization of resource exploitation.

  7. Radar tracking with an interacting multiple model and probabilistic data association filter for civil aviation applications.

    PubMed

    Jan, Shau-Shiun; Kao, Yu-Chun

    2013-05-17

    The current trend of the civil aviation technology is to modernize the legacy air traffic control (ATC) system that is mainly supported by many ground based navigation aids to be the new air traffic management (ATM) system that is enabled by global positioning system (GPS) technology. Due to the low receiving power of GPS signal, it is a major concern to aviation authorities that the operation of the ATM system might experience service interruption when the GPS signal is jammed by either intentional or unintentional radio-frequency interference. To maintain the normal operation of the ATM system during the period of GPS outage, the use of the current radar system is proposed in this paper. However, the tracking performance of the current radar system could not meet the required performance of the ATM system, and an enhanced tracking algorithm, the interacting multiple model and probabilistic data association filter (IMMPDAF), is therefore developed to support the navigation and surveillance services of the ATM system. The conventional radar tracking algorithm, the nearest neighbor Kalman filter (NNKF), is used as the baseline to evaluate the proposed radar tracking algorithm, and the real flight data is used to validate the IMMPDAF algorithm. As shown in the results, the proposed IMMPDAF algorithm could enhance the tracking performance of the current aviation radar system and meets the required performance of the new ATM system. Thus, the current radar system with the IMMPDAF algorithm could be used as an alternative system to continue aviation navigation and surveillance services of the ATM system during GPS outage periods.

  8. The impact of extensive loss of telecommunications on general practice: A case study in rural Victoria.

    PubMed

    Tran, Nancy H; Pedler, Daryl

    2017-04-01

    To describe the impact of major loss of telecommunications on general practice in a rural region of Australia. A multi-stage qualitative study. Purposively selected participants were invited to contribute to initial data collection using an online survey, followed by interviews with selected participants. Thematic analysis of the data was performed by both research team members. South-western Victoria, Australia. Individuals from organisations involved in Telstra recovery efforts, disaster management, health care and general practice staff. The survey collected freeform responses from participants. Semi-structured interviews further explored a variety of experiences from purposively selected participants. Organisations and practices in the region were prepared for major disasters, but not for the unusual and 'limited' disaster of losing telecommunications, including lack of Internet access and loss of telephone services. Although alternative measures were found for telecommunications, there was still a significant impact on many health-care-related activities and general practice functionality during the outage period. In particular, there was an increase in duties for administrative staff to compensate for loss of telecommunications. Patient traffic for many services decreased due to uncertainty about availability and continuation of business. The Warrnambool outage could be used as a case study illustrating the dramatic impact of communication loss. Major impacts include changes in patient traffic, increased administrative duties and slowing of patient care. When developing or assessing disaster management plans, general practices should consider the impact of telecommunication loss on functionality and prepare appropriate alternative, accessible and reliable measures. © 2016 National Rural Health Alliance Inc.

  9. Contingency Operations during Failure of Inertial Attitude Acquisition Due to Star Tracker Blinding for Three-Axes-Stabilized Interplanetary Spacecraft

    NASA Technical Reports Server (NTRS)

    Keil, Joachim; Herfort, Ulrich

    2007-01-01

    The three interplanetary ESA missions Mars-Express, Rosetta and Venus-Express (launched 2003, 2004 and 2005 resp.) are three-axes stabilized spacecraft (s/c) that estimate their inertial attitude (i.e. the attitude of the s/c w.r.t. the inertial frame) using measurements from a redundant set of star trackers (STR). Each s/c is equipped with four reaction wheels, a reaction control system based on thrusters and a redundant set of ring laser gyroscopes (gyros). The STR h/w layout of the three s/c is identical whereas there is a difference in the star pattern recognition algorithm of Rosetta which uses five neighbouring stars around a central star instead of star triads. The Rosetta algorithm has been implemented to cope with the presence of false stars which are expected to be seen during operations around the comet. The attitude acquisition capability from lost in space is different also in terms of AOCMS: The survival mode of Rosetta which is entered upon STR failure is presented. The AOCMS of Mars- and Venus-Express manages temporary STR outages during sky occultation by the planet not even by using redundancy. Though, a blinding of both STR during cruise lasting for the order of days confronts the ground operators with the limits of the AOCMS design. The operations and analyses that have been planned and partially been performed to compensate for the outage of the STR are demonstrated for Mars-Express. The caution measures taken before Venus orbit insertion of Venus-Express are detailed.

  10. Radar Tracking with an Interacting Multiple Model and Probabilistic Data Association Filter for Civil Aviation Applications

    PubMed Central

    Jan, Shau-Shiun; Kao, Yu-Chun

    2013-01-01

    The current trend of the civil aviation technology is to modernize the legacy air traffic control (ATC) system that is mainly supported by many ground based navigation aids to be the new air traffic management (ATM) system that is enabled by global positioning system (GPS) technology. Due to the low receiving power of GPS signal, it is a major concern to aviation authorities that the operation of the ATM system might experience service interruption when the GPS signal is jammed by either intentional or unintentional radio-frequency interference. To maintain the normal operation of the ATM system during the period of GPS outage, the use of the current radar system is proposed in this paper. However, the tracking performance of the current radar system could not meet the required performance of the ATM system, and an enhanced tracking algorithm, the interacting multiple model and probabilistic data association filter (IMMPDAF), is therefore developed to support the navigation and surveillance services of the ATM system. The conventional radar tracking algorithm, the nearest neighbor Kalman filter (NNKF), is used as the baseline to evaluate the proposed radar tracking algorithm, and the real flight data is used to validate the IMMPDAF algorithm. As shown in the results, the proposed IMMPDAF algorithm could enhance the tracking performance of the current aviation radar system and meets the required performance of the new ATM system. Thus, the current radar system with the IMMPDAF algorithm could be used as an alternative system to continue aviation navigation and surveillance services of the ATM system during GPS outage periods. PMID:23686142

  11. New Innovations in Highly Ion Specific Media for Recalcitrant Waste stream Radioisotopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denton, M. S.; Wilson, J.; Ahrendt, M.

    Specialty ion specific media were examined and developed for, not only pre- and post-outage waste streams, but also for very difficult outage waste streams. This work was carried out on first surrogate waste streams, then laboratory samples of actual waste streams, and, finally, actual on-site waste streams. This study was particularly focused on PWR wastewaters such as Floor Drain Tank (FDT), Boron Waste Storage Tank (BWST), and Waste Treatment Tank (WTT, or discharge tank). Over the last half decade, or so, treatment technologies have so greatly improved and discharge levels have become so low, that certain particularly problematic isotopes, recalcitrantmore » to current treatment skids, are all that remain prior to discharge. In reality, they have always been present, but overshadowed by the more prevalent and higher activity isotopes. Such recalcitrants include cobalt, especially Co 58 [both ionic/soluble (total dissolved solids, TDS) and colloidal (total suspended solids, TSS)] and antimony (Sb). The former is present in most FDT and BWST wastewaters, while the Sb is primarily present in BWST waste streams. The reasons Co 58 can be elusive to granulated activated carbon (GAC), ultrafiltration (UF) and ion exchange (IX) demineralizers is that it forms submicron colloids as well as has a tendency to form metal complexes with chelating agents (e.g., ethylene diamine tetraacetic acid, or EDTA). Such colloids and non-charged complexes will pass through the entire treatment skid. Antimony (Sb) on the other hand, has little or no ionic charge, and will, likewise, pass through both the filtration and de-min skids into the discharge tanks. While the latter will sometimes (the anionic vs. the cationic or neutral species) be removed on the anion bed(s), it will slough off (snow-plow effect) when a higher affinity anion (iodine slugs, etc.) comes along; thus causing effluents not meeting discharge criteria. The answer to these problems found in this study, during an actual Nuclear Power Plant (NPP) outage cycle and recovery (four months), was the down-select and development of a number of highly ion specific media for the specific removal of such elusive isotopes. Over three dozen media including standard cation and anion ion exchangers, specialty IX, standard carbons, and, finally, chemically doped media (e.g., carbon and alumina substrates). The latter involved doping with iron, manganese, and even metals. The media down-select was carried out on actual plant waste streams so that all possible outage affects were accounted for, and distribution coefficients (Kd's) were determined (vs. decontamination factors, DF's, or percent removals). Such Kd's, in milliliters of solution per gram of media (mug), produce data indicative of the longevity of the media in that particular waste stream. Herein, the down-select is reported in Pareto (decreasing order) tables. Further affects such as the presence of high cobalt concentrations, high boron concentrations, the presence of hydrazine and chelating agents, and extreme pH conditions. Of particular importance here is to avoid the affinity of competing ions (e.g., a Sb specific media having more than a slight affinity for Co). The latter results in the snow-plow effect of sloughing off 3 to 4 times the cobalt into the effluent as was in the feed upon picking up the Sb. The study was quite successful and resulted in the development of and selection of a resin-type and two granular media for antimony removal, and two resin-types and a granular media for cobalt removal. The decontamination factors for both media were hundreds to thousands of times that of the full filtration and de-min. (authors)« less

  12. INTEGRATED MONITORING HARDWARE DEVELOPMENTS AT LOS ALAMOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. PARKER; J. HALBIG; ET AL

    1999-09-01

    The hardware of the integrated monitoring system supports a family of instruments having a common internal architecture and firmware. Instruments can be easily configured from application-specific personality boards combined with common master-processor and high- and low-voltage power supply boards, and basic operating firmware. The instruments are designed to function autonomously to survive power and communication outages and to adapt to changing conditions. The personality boards allow measurement of gross gammas and neutrons, neutron coincidence and multiplicity, and gamma spectra. In addition, the Intelligent Local Node (ILON) provides a moderate-bandwidth network to tie together instruments, sensors, and computers.

  13. BPTAP: A New Approach to IP over DTN

    NASA Technical Reports Server (NTRS)

    Tsao, Philip; Nguyen, Sam

    2012-01-01

    Traditional Internet protocols have been widely deployed for a variety of applications. However such protocols generally perform poorly in situations in which, round trip delays are very large (interplanetary distances) or . persistent connectivity is not always available (widely dispersed MANET). Delay/Disruption Tolerant Network (DTN) technology was invented to address these issues: (1) . Relay nodes "take custody" of blocks of network traffic on a hop-by -hop basis and retransmit them in cases of expected or unexpected link outage (2) Bundle lifetime may be configured for long round trip light times. BPTAP is novel by encapsulating Ethernet frames in BP

  14. Licensed operating reactors: Status summary report, data as of December 31, 1995. Volume 20

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-06-01

    The US Nuclear Regulatory Commission`s monthly summary of licensed nuclear power reactor data is based primarily on the operating data report submitted by licensees for each unit. This report is divided into two sections: the first contains summary highlights and the second contains data on each individual unit in commercial operation. Section 1 availability factors, capacity factors, and forced outage rates are simple arithmetic averages. Section 2 items in the cumulative column are generally as reported by the licensees and notes to the use of weighted averages and starting dates other than commercial operation are provided.

  15. Intelligent Chemistry Management System (ICMS)--A new approach to steam generator chemistry control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barto, R.J.; Farrell, D.M.; Noto, F.A.

    1986-04-01

    The Intelligent Chemistry Management System (ICMS) is a new tool which assists in steam generator chemistry control. Utilizing diagnostic capabilities, the ICMS will provide utility and industrial boiler operators, system chemists, and plant engineers with a tool for monitoring, diagnosing, and controlling steam generator system chemistry. By reducing the number of forced outages through early identification of potentially detrimental conditions, suggestion of possible causes, and execution of corrective actions, improvements in unit availability and reliability will result. The system monitors water and steam quality at a number of critical locations in the plant.

  16. Battery Storage Evaluation Tool, version 1.x

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-10-02

    The battery storage evaluation tool developed at Pacific Northwest National Laboratory is used to run a one-year simulation to evaluate the benefits of battery storage for multiple grid applications, including energy arbitrage, balancing service, capacity value, distribution system equipment deferral, and outage mitigation. This tool is based on the optimal control strategies to capture multiple services from a single energy storage device. In this control strategy, at each hour, a lookahead optimization is first formulated and solved to determine the battery base operating point. The minute-by-minute simulation is then performed to simulate the actual battery operation.

  17. A Stable Clock Error Model Using Coupled First and Second Order Gauss-Markov Processes

    NASA Technical Reports Server (NTRS)

    Carpenter, Russell; Lee, Taesul

    2008-01-01

    Long data outages may occur in applications of global navigation satellite system technology to orbit determination for missions that spend significant fractions of their orbits above the navigation satellite constellation(s). Current clock error models based on the random walk idealization may not be suitable in these circumstances, since the covariance of the clock errors may become large enough to overflow flight computer arithmetic. A model that is stable, but which approximates the existing models over short time horizons is desirable. A coupled first- and second-order Gauss-Markov process is such a model.

  18. 77 FR 41481 - Integration of Variable Energy Resources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ...The Federal Energy Regulatory Commission is amending the pro forma Open Access Transmission Tariff to remove unduly discriminatory practices and to ensure just and reasonable rates for Commission- jurisdictional services. Specifically, this Final Rule removes barriers to the integration of variable energy resources by requiring each public utility transmission provider to: offer intra-hourly transmission scheduling; and, incorporate provisions into the pro forma Large Generator Interconnection Agreement requiring interconnection customers whose generating facilities are variable energy resources to provide meteorological and forced outage data to the public utility transmission provider for the purpose of power production forecasting.

  19. Optimizing Storage and Renewable Energy Systems with REopt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elgqvist, Emma M.; Anderson, Katherine H.; Cutler, Dylan S.

    Under the right conditions, behind the meter (BTM) storage combined with renewable energy (RE) technologies can provide both cost savings and resiliency. Storage economics depend not only on technology costs and avoided utility rates, but also on how the technology is operated. REopt, a model developed at NREL, can be used to determine the optimal size and dispatch strategy for BTM or off-grid applications. This poster gives an overview of three applications of REopt: Optimizing BTM Storage and RE to Extend Probability of Surviving Outage, Optimizing Off-Grid Energy System Operation, and Optimizing Residential BTM Solar 'Plus'.

  20. Application of flywheel battery in mobile power station

    NASA Astrophysics Data System (ADS)

    Wang, Xinggui; Zhang, Bing; Li, Xiaoying; Sun, Xiaojing

    2013-03-01

    The flywheel battery is used to the mobile station for continuous power supply, once the commercial power or other independent power supply is outage or failure, the flywheel battery will provide uninterrupted power supply during the switch to the commercial power and the diesel generator sets, ensuring the power supply system is continuous and maintaining the performance and parameters of the power supply which will not influence or discontinuous change because of commercial power failure. Simulation results show that the flywheel battery used to the mobile station can effectively improve the performance of the mobile power station system.

  1. Application of Financial Risk-reward Theory to Link and Network Optimization

    DTIC Science & Technology

    2011-10-01

    OFDM systems the matrices V k and U k are Fourier matrices which diagonalize a circulant or block-circulant matrix Hk [18]. In multi-antenna systems...probability α=Pr(η r <=t) Figure 13: Mean link spectral efficiency as a function of target link spectral efficiency ηt and outage probability ζ in a MIMO ...in a MIMO channel. Distribution A: Approved for public release; distribution is unlimited. 41 (75) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 2 4 6 8

  2. Simulation of switching overvoltages in the mine electric power supply system

    NASA Astrophysics Data System (ADS)

    Ivanchenko, D. I.; Novozhilov, N. G.

    2017-02-01

    Overvoltages occur in mine power supply systems during switching off consumers with high inductive load, such as transformers, reactors and electrical machines. Overvoltages lead to an increase of insulation degradation rate and may cause electric faults, power outage, fire and explosion of methane and coal dust. This paper is dedicated to simulation of vacuum circuit breaker switching overvoltages in a mine power supply system by means of Simulink MATLAB. The model of the vacuum circuit breaker implements simulation of transient recovery voltage, current chopping and an electric arc. Obtained results were compared to available experimental data.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckman, Todd J.; Hertzel, Ali K.; Lane, James J.

    In 2013, the U.S. Department of Energy's (DOE) Hanford Site, located in Washington State, funded an update to the critical network infrastructure supporting the Hanford Federal Cloud (HFC). The project, called ET-50, was the final step in a plan that was initiated five years ago called "Hanford's IT Vision, 2015 and Beyond." The ET-50 project upgraded Hanford's core data center switches and routers along with a majority of the distribution layer switches. The upgrades allowed HFC the network intelligence to provide Hanford with a more reliable and resilient network architecture. The culmination of the five year plan improved network intelligencemore » and high performance computing as well as helped to provide 10 Gbps capable links between core backbone devices (10 times the previous bandwidth). These improvements allow Hanford the ability to further support bandwidth intense applications, such as video teleconferencing. The ET-50 switch upgrade, along with other upgrades implemented from the five year plan, have prepared Hanford's network for the next evolution of technology in voice, video, and data. Hand-in-hand with ET-50's major data center outage, Mission Support Alliance's (MSA) Information Management (IM) organization executed a disaster recovery (DR) exercise to perform a true integration test and capability study. The DR scope was planned within the constraints of ET-50's 14 hour datacenter outage window. This DR exercise tested Hanford's Continuity of Operations (COOP) capability and failover plans for safety and business critical Hanford Federal Cloud applications. The planned suite of services to be tested was identified prior to the outage and plans were prepared to test the services ability to failover from the primary Hanford data center to the backup data center. The services tested were: Core Network (backbone, firewall, load balancers); Voicemail; Voice over IP (VoIP); Emergency Notification; Virtual desktops; and, Select set of production applications and data. The primary objective of the exercise was to test COOP around the emergency operations at Hanford to provide information on capabilities and dependencies of the current system to insure improved focus of emergency, safety and security capacity in a disaster situation. The integration of the DR test into the ET-50 project allowed the testing of COOP at Hanford and allowed the lessons learned to be defined. These lessons learned have helped improve the understanding of Hanford's COOP capabilities and will be critical for future planning. With the completion of the Hanford Federal Cloud network upgrades and the disaster recovery exercise, the MSA has a clearer path forward for future technology implementations as well as network improvements to help shape the usability and reliability of the Hanford network in support of the cleanup mission.« less

  4. Data Relay Board with Protocol for High-Speed, Free-Space Optical Communications

    NASA Technical Reports Server (NTRS)

    Wright, Malcolm; Clare, Loren; Gould, Gary; Pedyash, Maxim

    2004-01-01

    In a free-space optical communication system, the mitigation of transient outages through the incorporation of error-control methods is of particular concern, the outages being caused by scintillation fades and obscurants. The focus of this innovative technology is the development of a data relay system for a reliable high-data-rate free-spacebased optical-transport network. The data relay boards will establish the link, maintain synchronous connection, group the data into frames, and provide for automatic retransmission (ARQ) of lost or erred frames. A certain Quality of Service (QoS) can then be ensured, compatible with the required data rate. The protocol to be used by the data relay system is based on the draft CCSDS standard data-link protocol Proximity-1, selected by orbiters to multiple lander assets in the Mars network, for example. In addition to providing data-link protocol capabilities for the free-space optical link and buffering the data, the data relay system will interface directly with user applications over Gigabit Ethernet and/or with highspeed storage resources via Fibre Channel. The hardware implementation is built on a network-processor-based architecture. This technology combines the power of a hardware switch capable of data switching and packet routing at Gbps rates, with the flexibility of a software- driven processor that can host highly adaptive and reconfigurable protocols used, for example, in wireless local-area networks (LANs). The system will be implemented in a modular multi-board fashion. The main hardware elements of the data relay system are the new data relay board developed by Rockwell Scientific, a COTS Gigabit Ethernet board for user interface, and a COTS Fibre Channel board that connects to local storage. The boards reside in a cPCI back plane, and can be housed in a VME-type enclosure.

  5. Exploring Crisis Management in U.S. Small Businesses

    NASA Astrophysics Data System (ADS)

    Williams, Jon

    As a critical infrastructure, the US electricity grid supplies electricity to 340 million people within eight separate regions. The power infrastructure is vulnerable to many types of disasters capable of severing supplies of electricity. The impact on the employees and communities when small- and medium-size enterprises are shut down due to disasters can be severe. The purpose of the quantitative comparative study was to explore small- and medium-size enterprises crisis management strategies in the case of power infrastructure vulnerabilities. Perceptions of small business leaders were probed about crisis management planning relevant to three secondary factors: prior experience of crises, threat perceptions, and planning self-efficacy. Participants completed an adapted questionnaire instrument based on a five-point Likert scale for six sub-factors including resilience through planning, financial impact, operational crisis management, the perfect storm, the aftermath of survival, and atrophy. The instrument also measured three additional factors to include, prior experience of crises, threat perceptions, and planning self-efficacy, across seven types of crises. The results of this study indicated that of the 276 respondents, 104 had no crisis plans, but 172 did have crisis plans. Of those who had implemented crisis plans, 19% had specific provisions to address power outages or attacks on the electrical grid. Of the respondents who had not planned for power outages nor experienced significant losses of power, a statistically significant number acknowledged an external threat to their business. The majority of respondents indicated that long-term planning was related to resilience; however, the migration of crisis understanding into the planning process or implementation was not implemented. This heightened awareness of potential crises without the corresponding development and implementation of mitigation crisis plans requires additional research to understand drivers effecting the decision making process with crisis managers.

  6. Diversity combining in laser Doppler vibrometry for improved signal reliability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dräbenstedt, Alexander

    2014-05-27

    Because of the speckle nature of the light reflected from rough surfaces the signal quality of a vibrometer suffers from varying signal power. Deep signal outages manifest themselves as noise bursts and spikes in the demodulated velocity signal. Here we show that the signal quality of a single point vibrometer can be substantially improved by diversity reception. This concept is widely used in RF communication and can be transferred into optical interferometry. When two statistically independent measurement channels are available which measure the same motion on the same spot, the probability for both channels to see a signal drop-out atmore » the same time is very low. We built a prototype instrument that uses polarization diversity to constitute two independent reception channels that are separately demodulated into velocity signals. Send and receive beams go through different parts of the aperture so that the beams can be spatially separated. The two velocity channels are mixed into one more reliable signal by a PC program in real time with the help of the signal power information. An algorithm has been developed that ensures a mixing of two or more channels with minimum resulting variance. The combination algorithm delivers also an equivalent signal power for the combined signal. The combined signal lacks the vast majority of spikes that are present in the raw signals and it extracts the true vibration information present in both channels. A statistical analysis shows that the probability for deep signal outages is largely decreased. A 60 fold improvement can be shown. The reduction of spikes and noise bursts reduces the noise in the spectral analysis of vibrations too. Over certain frequency bands a reduction of the noise density by a factor above 10 can be shown.« less

  7. Space-based Scintillation Nowcasting with the Communications/Navigation Outage Forecast System

    NASA Astrophysics Data System (ADS)

    Groves, K.; Starks, M.; Beach, T.; Basu, S.

    2008-12-01

    The Air Force Research Laboratory's Communication/Navigation Outage Forecast System (C/NOFS) fuses ground- and space-based data in a near real-time physics-based model aimed at forecasting and nowcasting equatorial scintillations and their impacts on satellite communications and navigation. A key component of the system is the C/NOFS satellite that was launched into a low-inclination (13°) elliptical orbit (400 km x 850 km) in April 2008. The satellite contains six sensors to measure space environment parameters including electron density and temperature, ion density and drift, electric and magnetic fields and neutral wind, as well as a tri-band radio beacon transmitting at 150 MHz, 400 MHz and 1067 MHz. Scintillation nowcasts are derived from measuring the one-dimensional in situ electron density fluctuations and subsequently modeling the propagation environment for satellite-to-ground radio links. The modeling process requires a number of simplifying assumptions regarding the three-dimensional structure of the ionosphere and the results are readily validated by comparisons with ground-based measurements of the satellite's tri-band beacon signals. In mid-September 2008 a campaign to perform detailed analyses of space-based scintillation nowcasts with numerous ground observations was conducted in the vicinity of Kwajalein Atoll, Marshall Islands. To maximize the collection of ground-truth data, the ALTAIR radar was employed to obtain detailed information on the spatial structure of the ionosphere during the campaign and to aid the improvement of space-based nowcasting algorithms. A comparison of these results will be presented; it appears that detailed information on the electron density structure is a limiting factor in modeling the scintillation environment from in situ observations.

  8. Water quality effects of intermittent water supply in Arraiján, Panama.

    PubMed

    Erickson, John J; Smith, Charlotte D; Goodridge, Amador; Nelson, Kara L

    2017-05-01

    Intermittent drinking water supply is common in low- and middle-income countries throughout the world and can cause water quality to degrade in the distribution system. In this study, we characterized water quality in one study zone with continuous supply and three zones with intermittent supply in the drinking water distribution network in Arraiján, Panama. Low or zero pressures occurred in all zones, and negative pressures occurred in the continuous zone and two of the intermittent zones. Despite hydraulic conditions that created risks for backflow and contaminant intrusion, only four of 423 (0.9%) grab samples collected at random times were positive for total coliform bacteria and only one was positive for E. coli. Only nine of 496 (1.8%) samples had turbidity >1.0 NTU and all samples had ≥0.2 mg/L free chlorine residual. In contrast, water quality was often degraded during the first-flush period (when supply first returned after an outage). Still, routine and first-flush water quality under intermittent supply was much better in Arraiján than that reported in a previous study conducted in India. Better water quality in Arraiján could be due to better water quality leaving the treatment plant, shorter supply outages, higher supply pressures, a more consistent and higher chlorine residual, and fewer contaminant sources near pipes. The results illustrate that intermittent supply and its effects on water quality can vary greatly between and within distribution networks. The study also demonstrated that monitoring techniques designed specifically for intermittent supply, such as continuous pressure monitoring and sampling the first flush, can detect water quality threats and degradation that would not likely be detected with conventional monitoring. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Impact of Hurricane Sandy on community pharmacies in severely affected areas of New York City: A qualitative assessment.

    PubMed

    Arya, Vibhuti; Medina, Eric; Scaccia, Allison; Mathew, Cathleen; Starr, David

    2016-01-01

    Hurricane Sandy was one of the most severe natural disasters to hit the Mid-Atlantic States in recent history. Community pharmacies were among the businesses affected, with flooding and power outages significantly reducing services offered by many pharmacies. The objectives of our study were to assess the impact of Hurricane Sandy on community pharmacies, both independently owned and chain, in the severely affected areas of New York City (NYC), including Coney Island, Staten Island, and the Rockaways, using qualitative methods, and propose strategies to mitigate the impact of future storms and disasters. Of the total 52 solicited pharmacies, 35 (67 percent) responded and were included in our analysis. Only 10 (29 percent) of the pharmacies surveyed reported having a generator during Hurricane Sandy; 37 percent reported being equipped with a generator at the time of the survey approximately 1 year later. Our findings suggest that issues other than power outages contributed more toward a pharmacy remaining operational after the storm. Of those surveyed, 26 (74 percent) suffered from structural damage (most commonly in Coney Island). Most pharmacies (71 percent) were able to reopen within 1 month. Despite staffing challenges, most pharmacies (88 percent) had enough pharmacists/staff to resume normal operations. Overall, 91 percent were aware of law changes for emergency medication access, and 81 percent found the information easy to obtain. This survey helped inform our work toward improved community resiliency. Our findings have helped us recognize community pharmacists as important stakeholders and refocus our energy toward developing sustained partnerships with them in NYC as part of our ongoing preparedness strategy.

  10. Reserve valuation in electric power systems

    NASA Astrophysics Data System (ADS)

    Ruiz, Pablo Ariel

    Operational reliability is provided in part by scheduling capacity in excess of the load forecast. This reserve capacity balances the uncertain power demand with the supply in real time and provides for equipment outages. Traditionally, reserve scheduling has been ensured by enforcing reserve requirements in the operations planning. An alternate approach is to employ a stochastic formulation, which allows the explicit modeling of the sources of uncertainty. This thesis compares stochastic and reserve methods and evaluates the benefits of a combined approach for the efficient management of uncertainty in the unit commitment problem. Numerical studies show that the unit commitment solutions obtained for the combined approach are robust and superior with respect to the traditional approach. These robust solutions are especially valuable in areas with a high proportion of wind power, as their built-in flexibility allows the dispatch of practically all the available wind power while minimizing the costs of operation. The scheduled reserve has an economic value since it reduces the outage costs. In several electricity markets, reserve demand functions have been implemented to take into account the value of reserve in the market clearing process. These often take the form of a step-down function at the reserve requirement level, and as such they may not appropriately represent the reserve value. The value of reserve is impacted by the reliability, dynamic and stochastic characteristics of system components, the system operation policies, and the economic aspects such as the risk preferences of the demand. In this thesis, these aspects are taken into account to approximate the reserve value and construct reserve demand functions. Illustrative examples show that the demand functions constructed have similarities with those implemented in some markets.

  11. Bayesian wavelet PCA methodology for turbomachinery damage diagnosis under uncertainty

    NASA Astrophysics Data System (ADS)

    Xu, Shengli; Jiang, Xiaomo; Huang, Jinzhi; Yang, Shuhua; Wang, Xiaofang

    2016-12-01

    Centrifugal compressor often suffers various defects such as impeller cracking, resulting in forced outage of the total plant. Damage diagnostics and condition monitoring of such a turbomachinery system has become an increasingly important and powerful tool to prevent potential failure in components and reduce unplanned forced outage and further maintenance costs, while improving reliability, availability and maintainability of a turbomachinery system. This paper presents a probabilistic signal processing methodology for damage diagnostics using multiple time history data collected from different locations of a turbomachine, considering data uncertainty and multivariate correlation. The proposed methodology is based on the integration of three advanced state-of-the-art data mining techniques: discrete wavelet packet transform, Bayesian hypothesis testing, and probabilistic principal component analysis. The multiresolution wavelet analysis approach is employed to decompose a time series signal into different levels of wavelet coefficients. These coefficients represent multiple time-frequency resolutions of a signal. Bayesian hypothesis testing is then applied to each level of wavelet coefficient to remove possible imperfections. The ratio of posterior odds Bayesian approach provides a direct means to assess whether there is imperfection in the decomposed coefficients, thus avoiding over-denoising. Power spectral density estimated by the Welch method is utilized to evaluate the effectiveness of Bayesian wavelet cleansing method. Furthermore, the probabilistic principal component analysis approach is developed to reduce dimensionality of multiple time series and to address multivariate correlation and data uncertainty for damage diagnostics. The proposed methodology and generalized framework is demonstrated with a set of sensor data collected from a real-world centrifugal compressor with impeller cracks, through both time series and contour analyses of vibration signal and principal components.

  12. STARTUP REACTIVITY ACCOUNTABILITY ATTRIBUTED TO ISOTOPIC TRANSMUTATIONS IN THE IRRADIATED BERYLLIUM REFLECTOR OF THE HIGH FLUX ISTOTOPE REACTOR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandler, David; Maldonado, G Ivan; Primm, Trent

    2010-01-01

    The objective of this study is to develop a methodology to predict the reactivity impact as a function of outage time between cycles of 3He, 6Li, and other poisons in the High Flux Isotope Reactor s (HFIR) beryllium reflector. The reactivity worth at startup of the HFIR has been incorrectly predicted in the past after the reactor has been shut-down for long periods of time. The incorrect prediction was postulated to be due to the erroneous calculation of 3He buildup in the beryllium reflector. It is necessary to develop a better estimate of the start-of-cycle symmetric critical control element positionsmore » since if the estimated and actual symmetrical critical control element positions differ by more than $1.55 in reactivity (approximately one-half inch in control element startup position), HFIR is to be shutdown and a technical evaluation is performed to resolve the discrepancy prior to restart. 3He is generated and depleted during operation, but during an outage, the depletion of 3He ceases because it is a stable isotope. 3He is born from the radioactive decay of tritium, and thus the concentration of 3He increases during shutdown. The computer program SCALE, specifically the TRITON and CSAS5 control modules including the KENO V.A, COUPLE, and ORIGEN functional modules were utilized in this study. An equation relating the down time (td) to the change in symmetric control element position was generated and validated against measurements for approximately 40 HFIR operating cycles. The newly-derived correlation was shown to improve accuracy of predictions for long periods of down time.« less

  13. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1. Volume 5: Analysis of core damage frequency from seismic events during mid-loop operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Budnitz, R.J.; Davis, P.R.; Ravindra, M.K.

    1994-08-01

    In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1) and the other at Sandia National Laboratories studying a boiling water reactor (Grand Gulf). Both the Brookhaven and Sandia projects have examined only accidents initiated by internal plant faults--so-called ``internal initiators.`` This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling shutdown conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. Thismore » report covers the seismic analysis at Surry Unit 1. All of the many systems modeling assumptions, component non-seismic failure rates, and human error rates that were used in the internal-initiator study at Surry have been adopted here, so that the results of the two studies can be as comparable as possible. Both the Brookhaven study and this study examine only two shutdown plant operating states (POSs) during refueling outages at Surry, called POS 6 and POS 10, which represent mid-loop operation before and after refueling, respectively. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POSs 6 and 10. The results of the analysis are that the core-damage frequency of earthquake-initiated accidents during refueling outages in POS 6 and POS 10 is found to be low in absolute terms, less than 10{sup {minus}6}/year.« less

  14. Concerns and perceptions immediately following Superstorm Sandy: ratings for property damage were higher than for health issues

    PubMed Central

    Burger, Joanna; Gochfeld, Michael

    2015-01-01

    Governmental officials, health and safety professionals, early responders, and the public are interested in the perceptions and concerns of people faced with a crisis, especially during and immediately after a disaster strikes. Reliable information can lead to increased individual and community preparedness for upcoming crises. The objective of this research was to evaluate concerns of coastal and central New Jersey residents within the first 100 days of Superstorm Sandy’s landfall. Respondents living in central New Jersey and Jersey shore communities were differentially impacted by the storm, with shore residents having higher evacuation rates (47% vs. 13%), more flood waters in their homes, longer power outages (average 23 vs. 6 days), and longer periods without Internet (29 vs. 6 days). Ratings of concerns varied both among and within categories as a function of location (central vs. coastal New Jersey), stressor level (ranging from 1 to 3 for combinations of power outages, high winds, and flooding), and demographics. Respondents were most concerned about property damage, health, inconveniences, ecological services, and nuclear power plants in that order. Respondents from the shore gave higher ratings to the concerns within each major category, compared to those from central Jersey. Four findings have implications for understanding future risk, recovery, and resiliency: (1) respondents with the highest stressor level (level 3) were more concerned about water damage than others, (2) respondents with flood damage were more concerned about water drainage and mold than others, (3) respondents with the highest stressor levels rated all ecological services higher than others, and (4) shore respondents rated all ecological services higher than central Jersey residents. These data provide information to design future preparedness plans, improve resiliency for future severe weather events, and reduce public health risk. PMID:27011757

  15. Reactivity Accountability Attributed to Reflector Poisons in the High Flux Isotope Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandler, David; Maldonado, G Ivan; Primm, Trent

    2009-12-01

    The objective of this study is to develop a methodology to predict the reactivity impact as a function of outage time between cycles of 3He, 6Li, and other poisons in the High Flux Isotope Reactor s (HFIR) beryllium reflector. The reactivity worth at startup of the HFIR has been incorrectly predicted in the past after the reactor has been shut-down for long periods of time. The incorrect prediction was postulated to be due to the erroneous calculation of 3He buildup in the beryllium reflector. It is necessary to develop a better estimate of the start-of-cycle symmetric critical control element positionsmore » since if the estimated and actual symmetrical critical control element positions differ by more than $1.55 in reactivity (approximately one-half inch in control element startup position), HFIR is to be shutdown and a technical evaluation is performed to resolve the discrepancy prior to restart. 3He is generated and depleted during operation, but during an outage, the depletion of 3He ceases because it is a stable isotope. 3He is born from the radioactive decay of tritium, and thus the concentration of 3He increases during shutdown. SCALE, specifically the TRITON and CSAS5 control modules including the KENO V.A, COUPLE, and ORIGEN functional modules were utilized in this study. An equation relating the down time (td) to the change in symmetric control element position was generated and validated against measurements for approximately 40 HFIR operating cycles. The newly-derived correlation was shown to improve accuracy of predictions for long periods of down time.« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreitman, Paul J.; Sirianni, Steve R.; Pillard, Mark M.

    Entergy recently performed an Extended Power Up-rate (EPU) on their Grand Gulf Nuclear Station, near Port Gibson, Mississippi. To support the EPU, a new Steam Dryer Assembly was installed during the last refueling outage. Due to limited access into the containment, the large Replacement Steam Dryer (RSD) had to be brought into the containment in pieces and then final assembly was completed on the refueling floor before installation into the reactor. Likewise, the highly contaminated Original Steam Dryer (OSD) had to be segmented into manageable sections, loaded into specially designed shielded containers, and rigged out of containment where they willmore » be safely stored until final disposal is accomplished at an acceptable waste repository. Westinghouse Nuclear Services was contracted by Entergy to segment, package and remove the OSD from containment. This work was performed on critical path during the most recent refueling outage. The segmentation was performed underwater to minimize radiation exposure to the workers. Special hydraulic saws were developed for the cutting operations based on Westinghouse designs previously used in Sweden to segment ABB Reactor Internals. The mechanical cutting method was selected because of its proven reliability and the minimal cutting debris that is generated by the process. Maintaining stability of the large OSD sections during cutting was accomplished using a custom built support stand that was installed into the Moisture Separator Pool after the Moisture Separator was installed back in the reactor vessel. The OSD was then moved from the Steam Dryer Pool to the Moisture Separator Pool for segmentation. This scenario resolved the logistical challenge of having two steam dryers and a moisture separator in containment simultaneously. A water filtration/vacuum unit was supplied to maintain water clarity during the cutting and handling operations and to collect the cutting chips. (authors)« less

  17. A Remote Monitoring System for Voltage, Current, Power and Temperature Measurements

    NASA Astrophysics Data System (ADS)

    Barakat, E.; Sinno, N.; Keyrouz, C.

    This paper presents a study and design of a monitoring system for the continuous measurement of electrical energy parameters such as voltage, current, power and temperature. This system is designed to monitor the data remotely over internet. The electronic power meter is based on a microcontroller from Microchip Technology Inc. PIC family. The design takes into consideration the correct operation in the event of an outage or brown out by recording the electrical values and the temperatures in EEPROM internally available in the microcontroller. Also a digital display is used to show the acquired measurements. A computer will remotely monitor the data over internet.

  18. Evidence for Gravity Wave Seeding of Convective Ionospheric Storms Possibly Initiated by Thunderstorms

    NASA Astrophysics Data System (ADS)

    Kelley, M. C.; Dao, E. V.

    2018-05-01

    With the increase in solar activity, the Communication/Outage Forecast System satellite decayed on orbit to below the F peak. As such, we can study the development of convective ionospheric storms and, most importantly, study large-scale seeding of the responsible instability. For decades, gravity has been suggested as being responsible for the long wavelengths in the range of 200 to 1,000 km, as are commonly observed using airglow and satellite data. Here we suggest that convective thunderstorms are a likely source of gravity waves and point out that recent theoretical analysis has shown this connection to be quite possible.

  19. Performance analysis of a coherent free space optical communication system based on experiment.

    PubMed

    Cao, Jingtai; Zhao, Xiaohui; Liu, Wei; Gu, Haijun

    2017-06-26

    Based on our previous study and designed experimental AO system with a 97-element continuous surface deformable mirror, we conduct the performance analysis of a coherent free space optical communication (FSOC) system for mixing efficiency (ME), bit error rate (BER) and outage probability under different Greenwood frequency and atmospheric coherent length. The results show that the influence of the atmospheric temporal characteristics on the performance is slightly stronger than that of the spatial characteristics when the receiving aperture and the number of sub-apertures are given. This analysis result provides a reference for the design of the coherent FSOC system.

  20. Personal notes [of D.S. Lewis, 7 September 1956 to 31 December 1959

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, D.S.

    1956-09-07

    This report is a copy of the personal log of D.S. Lewis of the Irradiation Processing Dept. of Reactor Operations at Hanford and covers the period from 7 September 1956 through 31 December 1959. Data are presented on the following: (1) basic reactor operating data, including daily operating data, outage resumes, injuries and incidents, charging and tube replacement rates, panellit gage (flowmeter) trip failures, and thermocouple failures, and (2) basic reactor information on the water plant, electrical distribution, VSR`s, HCR`s, Ball 3X, Safety circuits, gas system, effluent system, process tube cross-section, and production scheduling.

  1. The Klamath Falls, Oregon, earthquakes on September 20, 1993

    USGS Publications Warehouse

    Brantley, S.R.

    1993-01-01

    The mainshocks caused light moderate damage at Klamath Falls, a town of about 18,000 residents located only about 20 km east of the epicentral area. Damage included toppled chimneys, cracked masonry, and fallen parapets. Power outages occurred after the strongest shocks. In addition, strong shaking broke water mains, and landslides temporarily blocked highways. the earthquakes also caused two fatalities. A rockfall crushed an automobile, killing a motorist, and an elderly lady had a heart attack. the low population density in the epicentral area- less than five people per sq km- kept the toatl dollar loss to about 7.5 million dollars. 

  2. Sparsity-aware multiple relay selection in large multi-hop decode-and-forward relay networks

    NASA Astrophysics Data System (ADS)

    Gouissem, A.; Hamila, R.; Al-Dhahir, N.; Foufou, S.

    2016-12-01

    In this paper, we propose and investigate two novel techniques to perform multiple relay selection in large multi-hop decode-and-forward relay networks. The two proposed techniques exploit sparse signal recovery theory to select multiple relays using the orthogonal matching pursuit algorithm and outperform state-of-the-art techniques in terms of outage probability and computation complexity. To reduce the amount of collected channel state information (CSI), we propose a limited-feedback scheme where only a limited number of relays feedback their CSI. Furthermore, a detailed performance-complexity tradeoff investigation is conducted for the different studied techniques and verified by Monte Carlo simulations.

  3. Decision support system for outage management and automated crew dispatch

    DOEpatents

    Kang, Ning; Mousavi, Mirrasoul

    2018-01-23

    A decision support system is provided for utility operations to assist with crew dispatch and restoration activities following the occurrence of a disturbance in a multiphase power distribution network, by providing a real-time visualization of possible location(s). The system covers faults that occur on fuse-protected laterals. The system uses real-time data from intelligent electronics devices coupled with other data sources such as static feeder maps to provide a complete picture of the disturbance event, guiding the utility crew to the most probable location(s). This information is provided in real-time, reducing restoration time and avoiding more costly and laborious fault location finding practices.

  4. NASA Launches NOAA Weather Satellite to Improve Forecasts

    NASA Image and Video Library

    2017-11-18

    Early on the morning of Saturday, Nov. 18, NASA successfully launched for the National Oceanic and Atmospheric Administration (NOAA) the first in a series of four advanced polar-orbiting satellites, equipped with next-generation technology and designed to improve the accuracy of U.S. weather forecasts out to seven days. The Joint Polar Satellite System-1 (JPSS-1) lifted off on a United Launch Alliance Delta II rocket from Vandenberg Air Force Base on California’s central coast. JPSS-1 data will improve weather forecasting and help agencies involved with post-storm recovery by visualizing storm damage and the geographic extent of power outages.

  5. Advanced Metering Infrastructure based on Smart Meters

    NASA Astrophysics Data System (ADS)

    Suzuki, Hiroshi

    By specifically designating penetrations rates of advanced meters and communication technologies, devices and systems, this paper introduces that the penetration of advanced metering is important for the future development of electric power system infrastructure. It examines the state of the technology and the economical benefits of advanced metering. One result of the survey is that advanced metering currently has a penetration of about six percent of total installed electric meters in the United States. Applications to the infrastructure differ by type of organization. Being integrated with emerging communication technologies, smart meters enable several kinds of features such as, not only automatic meter reading but also distribution management control, outage management, remote switching, etc.

  6. Development of bubble memory recorder onboard Japan Earth Resources Satellite-1

    NASA Astrophysics Data System (ADS)

    Araki, Tsunehiko; Ishida, Chu; Ochiai, Kiyoshi; Nozue, Tatsuhiro; Tachibana, Kyozo; Yoshida, Kazutoshi

    The Bubble Memory Recorder (BMR) developed for use on the Earth Resources Satellite is described in terms of its design, capabilities, and functions. The specifications of the BMR are given listing memory capacity, functions, and interface types for data, command, and telemetry functions. The BMR has an emergency signal interface to provide contingency recording, and a satellite-separation signal interface can be turned on automatically by signal input. Data are stored in a novolatile memory device so that the memory is retained during power outages. The BMR is characterized by a capability for random access, nonvolatility, and a solid-state design that is useful for space operations since it does not disturb spacecraft attitude.

  7. PNNL’s Shared Perspectives Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2015-09-25

    Shared Perspectives, one of the technologies within the PNNL-developed GridOPTICS capability suite, enables neighboring organizations, such as different electric utilities, to more effectively partner to solve outages and other grid problems. Shared Perspectives provides a means for organizations to safely stream information from different organizational service areas; the technology then combines and aligns this information into a common, global view, enhancing global situation awareness that can reduce the time it takes to talk through a problem and identify solutions. The technology potentially offers applications in other areas, such as disaster response; collaboration in the monitoring/assessment of real-time events (e.g., hurricanes,more » earthquakes, and tornadoes); as well as military uses.« less

  8. PNNL’s Shared Perspectives Technology

    ScienceCinema

    None

    2018-01-16

    Shared Perspectives, one of the technologies within the PNNL-developed GridOPTICS capability suite, enables neighboring organizations, such as different electric utilities, to more effectively partner to solve outages and other grid problems. Shared Perspectives provides a means for organizations to safely stream information from different organizational service areas; the technology then combines and aligns this information into a common, global view, enhancing global situation awareness that can reduce the time it takes to talk through a problem and identify solutions. The technology potentially offers applications in other areas, such as disaster response; collaboration in the monitoring/assessment of real-time events (e.g., hurricanes, earthquakes, and tornadoes); as well as military uses.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piette, Mary Ann

    California needs new, responsive, demand-side energy technologies to ensure that periods of tight electricity supply on the grid don't turn into power outages. Led by Berkeley Lab's Mary Ann Piette, the California Energy Commission (through its Public Interest Energy Research Program) has established a Demand Response Research Center that addresses two motivations for adopting demand responsiveness: reducing average electricity prices and preventing future electricity crises. The research seeks to understand factors that influence "what works" in Demand Response. Piette's team is investigating the two types of demand response, load response and price response, that may influence and reduce the usemore » of peak electric power through automated controls, peak pricing, advanced communications, and other strategies.« less

  10. An Energy Storage Assessment: Using Optimal Control Strategies to Capture Multiple Services

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Di; Jin, Chunlian; Balducci, Patrick J.

    2015-09-01

    This paper presents a methodology for evaluating benefits of battery storage for multiple grid applications, including energy arbitrage, balancing service, capacity value, distribution system equipment deferral, and outage mitigation. In the proposed method, at each hour, a look-ahead optimization is first formulated and solved to determine battery base operating point. The minute by minute simulation is then performed to simulate the actual battery operation. This methodology is used to assess energy storage alternatives in Puget Sound Energy System. Different battery storage candidates are simulated for a period of one year to assess different value streams and overall benefits, as partmore » of a financial feasibility evaluation of battery storage projects.« less

  11. Analyzing the reliability of mechanical parts in 10 kV aerial transmission lines under ice-coating and wind effects in view of their design features

    NASA Astrophysics Data System (ADS)

    Doletskaya, L. I.; Solopov, R. V.; Kavchenkov, V. P.; Andreenkov, E. S.

    2017-12-01

    The physical features of the damage of aerial lines with a voltage of 10 kV under ice and wind loads are examined, mathematical models for estimating the reliability the mechanical part in aerial lines with the application of analytical theoretical methods and corresponding mathematical models taking into account the probabilistic nature of ice and wind loads are described, calculation results on reliability, specific damage and average time for restoration in case of emergency outages of 10 kV high-voltage transmission aerial lines with the use of uninsulated and protected wires are presented.

  12. Defending the Power Grid from Hackers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eber, Kevin

    A new initiative underway at the National Renewable Energy Laboratory is intended to prevent hackers from gaining control of parts of the nation's power grid, potentially damaging electrical equipment and causing localized power outages. Our nation's power grid is evolving to be more responsive to changing power needs, more able to integrate renewable energy, more efficient, and more reliable. One key element of this evolution is adding communication and control devices to the power grid, closer to the end user, so that utilities have greater situational awareness of the grid and can respond quickly to disturbances. But these new devicesmore » and their communications requirements can also open up the power grid to potential cyber attacks.« less

  13. Saving Power at Peak Hours (LBNL Science at the Theater)

    ScienceCinema

    Piette, Mary Ann [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2018-05-23

    California needs new, responsive, demand-side energy technologies to ensure that periods of tight electricity supply on the grid don't turn into power outages. Led by Berkeley Lab's Mary Ann Piette, the California Energy Commission (through its Public Interest Energy Research Program) has established a Demand Response Research Center that addresses two motivations for adopting demand responsiveness: reducing average electricity prices and preventing future electricity crises. The research seeks to understand factors that influence "what works" in Demand Response. Piette's team is investigating the two types of demand response, load response and price response, that may influence and reduce the use of peak electric power through automated controls, peak pricing, advanced communications, and other strategies.

  14. Performance analysis of dual-hop optical wireless communication systems over k-distribution turbulence channel with pointing error

    NASA Astrophysics Data System (ADS)

    Mishra, Neha; Sriram Kumar, D.; Jha, Pranav Kumar

    2017-06-01

    In this paper, we investigate the performance of the dual-hop free space optical (FSO) communication systems under the effect of strong atmospheric turbulence together with misalignment effects (pointing error). We consider a relay assisted link using decode and forward (DF) relaying protocol between source and destination with the assumption that Channel State Information is available at both transmitting and receiving terminals. The atmospheric turbulence channels are modeled by k-distribution with pointing error impairment. The exact closed form expression is derived for outage probability and bit error rate and illustrated through numerical plots. Further BER results are compared for the different modulation schemes.

  15. A Method of Synchrophasor Technology for Detecting and Analyzing Cyber-Attacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCann, Roy; Al-Sarray, Muthanna

    Studying cybersecurity events and analyzing their impacts encourage planners and operators to develop innovative approaches for preventing attacks in order to avoid outages and other disruptions. This work considers two parts in security studies; detecting an integrity attack and examining its effects on power system generators. The detection was conducted through employing synchrophasor technology to provide authentication of ACG commands based on observed system operating characteristics. The examination of an attack is completed via a detailed simulation of a modified IEEE 68-bus benchmark model to show the associated power system dynamic response. The results of the simulation are discussed formore » assessing the impacts of cyber threats.« less

  16. Response of human populations to large-scale emergencies

    NASA Astrophysics Data System (ADS)

    Bagrow, James; Wang, Dashun; Barabási, Albert-László

    2010-03-01

    Until recently, little quantitative data regarding collective human behavior during dangerous events such as bombings and riots have been available, despite its importance for emergency management, safety and urban planning. Understanding how populations react to danger is critical for prediction, detection and intervention strategies. Using a large telecommunications dataset, we study for the first time the spatiotemporal, social and demographic response properties of people during several disasters, including a bombing, a city-wide power outage, and an earthquake. Call activity rapidly increases after an event and we find that, when faced with a truly life-threatening emergency, information rapidly propagates through a population's social network. Other events, such as sports games, do not exhibit this propagation.

  17. Network survivability performance

    NASA Astrophysics Data System (ADS)

    1993-11-01

    This technical report has been developed to address the survivability of telecommunications networks including services. It responds to the need for a common understanding of, and assessment techniques for network survivability, availability, integrity, and reliability. It provides a basis for designing and operating telecommunications networks to user expectations for network survivability and a foundation for continuing industry activities in the subject area. This report focuses on the survivability of both public and private networks and covers a wide range of users. Two frameworks are established for quantifying and categorizing service outages, and for classifying network survivability techniques and measures. The performance of the network survivability techniques is considered; however, recommended objectives are not established for network survivability performance.

  18. Charge Analyzer Responsive Local Oscillations

    NASA Technical Reports Server (NTRS)

    Krause, Linda Habash; Thornton, Gary

    2015-01-01

    The first transatlantic radio transmission, demonstrated by Marconi in December of 1901, revealed the essential role of the ionosphere for radio communications. This ionized layer of the upper atmosphere controls the amount of radio power transmitted through, reflected off of, and absorbed by the atmospheric medium. Low-frequency radio signals can propagate long distances around the globe via repeated reflections off of the ionosphere and the Earth's surface. Higher frequency radio signals can punch through the ionosphere to be received at orbiting satellites. However, any turbulence in the ionosphere can distort these signals, compromising the performance or even availability of space-based communication and navigations systems. The physics associated with this distortion effect is analogous to the situation when underwater images are distorted by convecting air bubbles. In fact, these ionospheric features are often called 'plasma bubbles' since they exhibit some of the similar behavior as underwater air bubbles. These events, instigated by solar and geomagnetic storms, can cause communication and navigation outages that last for hours. To help understand and predict these outages, a world-wide community of space scientists and technologists are devoted to researching this topic. One aspect of this research is to develop instruments capable of measuring the ionospheric plasma bubbles. Figure 1 shows a photo of the Charge Analyzer Responsive to Local Oscillations (CARLO), a new instrument under development at NASA Marshall Space Flight Center (MSFC). It is a frequency-domain ion spectrum analyzer designed to measure the distributions of ionospheric turbulence from 1 Hz to 10 kHz (i.e., spatial scales from a few kilometers down to a few centimeters). This frequency range is important since it focuses on turbulence scales that affect VHF/UHF satellite communications, GPS systems, and over-the-horizon radar systems. CARLO is based on the flight-proven Plasma Local Anomalous Noise Environment (PLANE) instrument, previously flown on a U.S. Air Force low-Earth orbiting satellite, which successfully measured ion turbulence in five frequency decades from 0.1 Hz to 10 kHz (fig 2).

  19. PFP Emergency Lighting Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BUSCH, M.S.

    2000-02-02

    NFPA 101, section 5-9 mandates that, where required by building classification, all designated emergency egress routes be provided with adequate emergency lighting in the event of a normal lighting outage. Emergency lighting is to be arranged so that egress routes are illuminated to an average of 1.0 footcandle with a minimum at any point of 0.1 footcandle, as measured at floor level. These levels are permitted to drop to 60% of their original value over the required 90 minute emergency lighting duration after a power outage. The Plutonium Finishing Plant (PFP) has two designations for battery powered egress lights ''Emergencymore » Lights'' are those battery powered lights required by NFPA 101 to provide lighting along officially designated egress routes in those buildings meeting the correct occupancy requirements. Emergency Lights are maintained on a monthly basis by procedure ZSR-12N-001. ''Backup Lights'' are battery powered lights not required by NFPA, but installed in areas where additional light may be needed. The Backup Light locations were identified by PFP Safety and Engineering based on several factors. (1) General occupancy and type of work in the area. Areas occupied briefly during a shiftly surveillance do not require backup lighting while a room occupied fairly frequently or for significant lengths of time will need one or two Backup lights to provide general illumination of the egress points. (2) Complexity of the egress routes. Office spaces with a standard hallway/room configuration will not require Backup Lights while a large room with several subdivisions or irregularly placed rooms, doors, and equipment will require Backup Lights to make egress safer. (3) Reasonable balance between the safety benefits of additional lighting and the man-hours/exposure required for periodic light maintenance. In some plant areas such as building 236-Z, the additional maintenance time and risk of contamination do not warrant having Backup Lights installed in all rooms. Sufficient light for egress is provided by existing lights located in the hallways.« less

  20. Modernizing Distribution System Restoration to Achieve Grid Resiliency Against Extreme Weather Events: An Integrated Solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chen; Wang, Jianhui; Ton, Dan

    Recent severe power outages caused by extreme weather hazards have highlighted the importance and urgency of improving the resilience of the electric power grid. As the distribution grids still remain vulnerable to natural disasters, the power industry has focused on methods of restoring distribution systems after disasters in an effective and quick manner. The current distribution system restoration practice for utilities is mainly based on predetermined priorities and tends to be inefficient and suboptimal, and the lack of situational awareness after the hazard significantly delays the restoration process. As a result, customers may experience an extended blackout, which causes largemore » economic loss. On the other hand, the emerging advanced devices and technologies enabled through grid modernization efforts have the potential to improve the distribution system restoration strategy. However, utilizing these resources to aid the utilities in better distribution system restoration decision-making in response to extreme weather events is a challenging task. Therefore, this paper proposes an integrated solution: a distribution system restoration decision support tool designed by leveraging resources developed for grid modernization. We first review the current distribution restoration practice and discuss why it is inadequate in response to extreme weather events. Then we describe how the grid modernization efforts could benefit distribution system restoration, and we propose an integrated solution in the form of a decision support tool to achieve the goal. The advantages of the solution include improving situational awareness of the system damage status and facilitating survivability for customers. The paper provides a comprehensive review of how the existing methodologies in the literature could be leveraged to achieve the key advantages. The benefits of the developed system restoration decision support tool include the optimal and efficient allocation of repair crews and resources, the expediting of the restoration process, and the reduction of outage durations for customers, in response to severe blackouts due to extreme weather hazards.« less