Sample records for outlet temperature limits

  1. 14 CFR 29.1521 - Powerplant limitations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... pressure (for reciprocating engines); (3) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (4) The maximum allowable power or torque for each engine, considering the... maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (5) The maximum...

  2. 14 CFR 29.1521 - Powerplant limitations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... pressure (for reciprocating engines); (3) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (4) The maximum allowable power or torque for each engine, considering the... maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (5) The maximum...

  3. 14 CFR 29.1521 - Powerplant limitations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... pressure (for reciprocating engines); (3) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (4) The maximum allowable power or torque for each engine, considering the... maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (5) The maximum...

  4. 14 CFR 29.1521 - Powerplant limitations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... pressure (for reciprocating engines); (3) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (4) The maximum allowable power or torque for each engine, considering the... maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (5) The maximum...

  5. 14 CFR 29.1521 - Powerplant limitations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... pressure (for reciprocating engines); (3) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (4) The maximum allowable power or torque for each engine, considering the... maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (5) The maximum...

  6. Water temperature effects from simulated changes to dam operations and structures in the Middle and South Santiam Rivers, Oregon

    USGS Publications Warehouse

    Buccola, Norman L.

    2017-05-31

    Green Peter and Foster Dams on the Middle and South Santiam Rivers, Oregon, have altered the annual downstream water temperature profile (cycle). Operation of the dams has resulted in cooler summer releases and warmer autumn releases relative to pre-dam conditions, and that alteration can hinder recovery of various life stages of threatened spring-run Chinook salmon (Oncorhyncus tshawytscha) and winter steelhead (O. mykiss). Lake level management and the use of multiple outlets from varying depths at the dams can enable the maintenance of a temperature regime more closely resembling that in which the fish evolved by releasing warm surface water during summer and cooler, deeper water in the autumn. At Green Peter and Foster Dams, the outlet configuration is such that temperature control is often limited by hydropower production at the dams. Previously calibrated CE-QUAL-W2 water temperature models of Green Peter and Foster Lakes were used to simulate the downstream thermal effects from hypothetical structures and modified operations at the dams. Scenarios with no minimum power production requirements allowed some releases through shallower and deeper outlets (summer and autumn) to achieve better temperature control throughout the year and less year-to-year variability in autumn release temperatures. Scenarios including a hypothetical outlet floating 1 meter below the lake surface resulted in greater ability to release warm water during summer compared to existing structures. Later in Autumn (October 15–December 31), a limited amount of temperature control was realized downstream from Foster Dam by scenarios limited to operational changes with existing structures, resulting in 15-day averages within 1.0 degree Celsius of current operations.

  7. 40 CFR Table 4 to Subpart Kkkk of... - Operating Limits If Using the Emission Rate With Add-on Controls Option or the Control Efficiency...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... outlet at or below the temperature limit. 6. Concentrators, including zeolite wheels and rotary carbon.... Collecting the temperature data including zeolite inlet temperature according to § 63.3547(f)ii. Reducing the...

  8. Improved Algorithms for Blending Dam Releases to Meet Downstream Water-Temperature Targets in the CE-QUAL-W2 Water-Quality Model

    NASA Astrophysics Data System (ADS)

    Rounds, S. A.; Buccola, N. L.

    2014-12-01

    The two-dimensional (longitudinal, vertical) water-quality model CE-QUAL-W2, version 3.7, was enhanced with new features to help dam operators and managers efficiently explore and optimize potential solutions for temperature management downstream of thermally stratified reservoirs. Such temperature management often is accomplished by blending releases from multiple dam outlets that access water of different temperatures at different depths in the reservoir. The original blending algorithm in this version of the model was limited to mixing releases from two outlets at a time, and few constraints could be imposed. The new enhanced blending algorithm allows the user to (1) specify a time-series of target release temperatures, (2) designate from 2 to 10 floating or fixed-elevation outlets for blending, (3) impose maximum head constraints as well as minimum and maximum flow constraints for any blended outlet, and (4) set a priority designation for each outlet that allows the model to choose which outlets to use and how to balance releases among them. The modified model was tested against a previously calibrated model of Detroit Lake on the North Santiam River in northwestern Oregon, and the results compared well. The enhanced model code is being used to evaluate operational and structural scenarios at multiple dam/reservoir systems in the Willamette River basin in Oregon, where downstream temperature management for endangered fish is a high priority for resource managers and dam operators. These updates to the CE-QUAL-W2 blending algorithm allow scenarios involving complicated dam operations and/or hypothetical outlet structures to be evaluated more efficiently with the model, with decreased need for multiple/iterative model runs or preprocessing of model inputs to fully characterize the operational constraints.

  9. The Society of Thoracic Surgeons, The Society of Cardiovascular Anesthesiologists, and The American Society of ExtraCorporeal Technology: Clinical Practice Guidelines for Cardiopulmonary Bypass--Temperature Management During Cardiopulmonary Bypass.

    PubMed

    Engelman, Richard; Baker, Robert A; Likosky, Donald S; Grigore, Alina; Dickinson, Timothy A; Shore-Lesserson, Linda; Hammon, John W

    2015-08-01

    In order to improve our understanding of the evidence-based literature supporting temperature management during adult cardiopulmonary bypass, The Society of Thoracic Surgeons, the Society of Cardiovascular Anesthesiology and the American Society of ExtraCorporeal Technology tasked the authors to conduct a review of the peer-reviewed literature, including: 1) optimal site for temperature monitoring, 2) avoidance of hyperthermia, 3) peak cooling temperature gradient and cooling rate, and 4) peak warming temperature gradient and rewarming rate. Authors adopted the American College of Cardiology/American Heart Association method for development clinical practice guidelines, and arrived at the following recommendations: CLASS I RECOMMENDATIONS: a)The oxygenator arterial outlet blood temperature is recommended to be utilized as a surrogate for cerebral temperature measurement during CPB. (Class I, Level C) b)To monitor cerebral perfusate temperature during warming, it should be assumed that the oxygenator arterial outlet blood temperature under-estimates cerebral perfusate temperature. (Class I, Level C) c)Surgical teams should limit arterial outlet blood temperature to<37°C to avoid cerebral hyperthermia. (Class 1, Level C) d)Temperature gradients between the arterial outlet and venous inflow on the oxygenator during CPB cooling should not exceed 10°C to avoid generation of gaseous emboli. (Class 1, Level C) e)Temperature gradients between the arterial outlet and venous inflow on the oxygenator during CPB rewarming should not exceed 10°C to avoid out-gassing when blood is returned to the patient. (Class 1, Level C) CLASS IIa a)Pulmonary artery or nasopharyngeal temperature recording is reasonable for weaning and immediate post-bypass temperature measurement. (Class IIa, Level C)b)Rewarming when arterial blood outlet temperature ≥30° C: i.To achieve the desired temperature for separation from bypass, it is reasonable to maintain a temperature gradient between arterial outlet temperature and the venous inflow of≤4°C. (Class IIa, Level B) ii.To achieve the desired temperature for separation from bypass, it is reasonable to maintain a rewarming rate≤0.5°C/min. (Class IIa, Level B) NO RECOMMENDATION: No recommendation for a guideline is provided concerning optimal temperature for weaning from CPB due to insufficient published evidence. Copyright © 2015. Published by Elsevier Inc.

  10. Simulating potential structural and operational changes for Detroit Dam on the North Santiam River, Oregon, for downstream temperature management

    USGS Publications Warehouse

    Buccola, Norman L.; Rounds, Stewart A.; Sullivan, Annett B.; Risley, John C.

    2012-01-01

    Detroit Dam was constructed in 1953 on the North Santiam River in western Oregon and resulted in the formation of Detroit Lake. With a full-pool storage volume of 455,100 acre-feet and a dam height of 463 feet, Detroit Lake is one of the largest and most important reservoirs in the Willamette River basin in terms of power generation, recreation, and water storage and releases. The U.S. Army Corps of Engineers operates Detroit Dam as part of a system of 13 reservoirs in the Willamette Project to meet multiple goals, which include flood-damage protection, power generation, downstream navigation, recreation, and irrigation. A distinct cycle in water temperature occurs in Detroit Lake as spring and summer heating through solar radiation creates a warm layer of water near the surface and isolates cold water below. Controlling the temperature of releases from Detroit Dam, therefore, is highly dependent on the location, characteristics, and usage of the dam's outlet structures. Prior to operational changes in 2007, Detroit Dam had a well-documented effect on downstream water temperature that was problematic for endangered salmonid fish species, releasing water that was too cold in midsummer and too warm in autumn. This unnatural seasonal temperature pattern caused problems in the timing of fish migration, spawning, and emergence. In this study, an existing calibrated 2-dimensional hydrodynamic water-quality model [CE-QUAL-W2] of Detroit Lake was used to determine how changes in dam operation or changes to the structural release points of Detroit Dam might affect downstream water temperatures under a range of historical hydrologic and meteorological conditions. The results from a subset of the Detroit Lake model scenarios then were used as forcing conditions for downstream CE-QUAL-W2 models of Big Cliff Reservoir (the small reregulating reservoir just downstream of Detroit Dam) and the North Santiam and Santiam Rivers. Many combinations of environmental, operational, and structural options were explored with the model scenarios. Multiple downstream temperature targets were used along with three sets of environmental forcing conditions representing cool/wet, normal, and hot/dry conditions. Five structural options at Detroit Dam were modeled, including the use of existing outlets, one hypothetical variable-elevation outlet such as a sliding gate, a hypothetical combination of a floating outlet and a fixed-elevation outlet, and a hypothetical combination of a floating outlet and a sliding gate. Finally, 14 sets of operational guidelines for Detroit Dam were explored to gain an understanding of the effects of imposing different downstream minimum streamflows, imposing minimum outflow rules to specific outlets, and managing the level of the lake with different timelines through the year. Selected subsets of these combinations of operational and structural scenarios were run through the downstream models of Big Cliff Reservoir and the North Santiam and Santiam Rivers to explore how hypothetical changes at Detroit Dam might provide improved temperatures for endangered salmonids downstream of the Detroit-Big Cliff Dam complex. Conclusions that can be drawn from these model scenarios include: *The water-temperature targets set by the U.S. Army Corps of Engineers for releases from Detroit Dam can be met through a combination of new dam outlets or a delayed drawdown of the lake in autumn. *Spring and summer dam operations greatly affect the available release temperatures and operational flexibility later in the autumn. Releasing warm water during midsummer tends to keep more cool water available for release in autumn. *The ability to meet downstream temperature targets during spring depends on the characteristics of the available outlets. Under existing conditions, although warm water sometimes is present at the lake surface in spring and early summer, such water may not be available for release if the lake level is either well below or well above the spillway crest. *Managing lake releases to meet downstream temperature targets depends on having outlet structures that can access both (warm) lake surface water and (cold) deeper lake water throughout the year. The existing outlets at Detroit Dam do not allow near-surface waters to be released during times when the lake surface level is below the spillway (spring and autumn). *Using the existing outlets at Detroit Dam, lake level management is important to the water temperature of releases because it controls the availability and depth of water at the spillway. When lake level is lowered below the spillway crest in late summer, the loss of access to warm water at the lake surface can result in abrupt changes to release temperatures. *Because the power-generation intakes (penstocks) are 166 feet below the full-pool lake level, imposing minimum power production requirements at Detroit Dam limits the amount of warm surface water that can be expelled from the lake in midsummer, thereby postponing and amplifying warm outflows from Detroit Lake into the autumn spawning season. *Likewise, imposing minimum power production requirements at Detroit Dam in autumn can limit the amount of cool hypolimnetic water that is released from the lake, thereby limiting cool outflows from Detroit Lake during the autumn spawning season. *Model simulations indicate that a delayed drawdown of Detroit Lake in autumn would result in better control over release temperatures in the immediate downstream vicinity of Big Cliff Dam, but the reduced outflows necessary to retain more water in the lake in late summer are more susceptible to rapid heating downstream. *Compared to the existing outlets at Detroit Dam, floating or sliding-gate outlet structures can provide greater control over release temperatures because they provide better access to warm water at the lake surface and cooler water at depth. These conclusions can be grouped into several common themes. First, optimal and flexible management and achievement of downstream temperature goals requires that releases of warm water near the surface of the lake and cold water below the thermocline are both possible with the available dam outlets during spring, summer, and autumn. This constraint can be met to some extent with existing outlets, but only if access to the spillway is extended into autumn by keeping the lake level higher than called for by the current rule curve (the typical target water-surface elevation throughout the year). If new outlets are considered, a variable-elevation outlet such as a sliding gate structure, or a floating outlet in combination with a fixed-elevation outlet at sufficient depth to access cold water, is likely to work well in terms of accessing a range of water temperatures and achieving downstream temperature targets. Furthermore, model results indicate that it is important to release warm water from near the lake surface during midsummer. If not released downstream, the warm water will build up at the top of the lake as a result of solar energy inputs and the thermocline will deepen, potentially causing warm water to reach the depth of deeper fixed-elevation outlets in autumn, particularly when the lake level is drawn down to make room for flood storage. Delaying the drawdown in autumn can help to keep the thermocline above such outlets and preserve access to cold water. Although it is important to generate hydropower at Detroit Dam, minimum power-production requirements limit the ability of dam operators to meet downstream temperature targets with existing outlet structures. The location of the power penstocks below the thermocline in spring and most of summer causes the release of more cool water during summer than is optimal. Reducing the power-production constraint allows the temperature target to be met more frequently, but at the cost of less power generation. Finally, running the Detroit Dam, Big Cliff Dam, and North Santiam and Santiam River models in series allows dam operators to evaluate how different operational strategies or combinations of new dam outlets might affect downstream temperatures for many miles of critical endangered salmonid habitat. Temperatures can change quickly in these downstream reaches as the river exchanges heat with its surroundings, and heating or cooling of 6 degrees Celsius is not unusual in the 40–50 miles downstream of Big Cliff Dam. The results published in this report supersede preliminary results published in U.S. Geological Survey Open-File Report 2011-1268 (Buccola and Rounds, 2011). Those preliminary results are still valid, but the results in this report are more current and comprehensive.

  11. 40 CFR 63.4966 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... capture system and add-on control device operating limits during the performance test? 63.4966 Section 63... system and add-on control device operating limits during the performance test? During the performance... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system...

  12. 40 CFR 63.4966 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... capture system and add-on control device operating limits during the performance test? 63.4966 Section 63... system and add-on control device operating limits during the performance test? During the performance... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system...

  13. Cooling Characteristics of the V-1650-7 Engine. II - Effect of Coolant Conditions on Cylinder Temperatures and Heat Rejection at Several Engine Powers

    NASA Technical Reports Server (NTRS)

    Povolny, John H.; Bogdan, Louis J.; Chelko, Louis J.

    1947-01-01

    An investigation has been conducted on a V-1650-7 engine to determine the cylinder temperatures and the coolant and oil heat rejections over a range of coolant flows (50 to 200 gal/min) and oil inlet temperatures (160 to 2150 F) for two values of coolant outlet temperature (250 deg and 275 F) at each of four power conditions ranging from approximately 1100 to 2000 brake horsepower. Data were obtained for several values of block-outlet pressure at each of the two coolant outlet temperatures. A mixture of 30 percent by volume of ethylene glycol and 70-percent water was used as the coolant. The effect of varying coolant flow, coolant outlet temperature, and coolant outlet pressure over the ranges investigated on cylinder-head temperatures was small (0 deg to 25 F) whereas the effect of increasing the engine power condition from ll00 to 2000 brake horsepower was large (maximum head-temperature increase, 110 F).

  14. 40 CFR 63.4966 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... system and add-on control device operating limits during the performance test? 63.4966 Section 63.4966... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system... Emission Rate with Add-on Controls Option § 63.4966 How do I establish the emission capture system and add...

  15. 40 CFR 63.4966 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system and add-on control device operating limits during the performance test? 63.4966 Section 63.4966... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system... with Add-on Controls Option § 63.4966 How do I establish the emission capture system and add-on control...

  16. 40 CFR 63.4966 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system and add-on control device operating limits during the performance test? 63.4966 Section 63.4966... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system... with Add-on Controls Option § 63.4966 How do I establish the emission capture system and add-on control...

  17. Availability of limited service food outlets surrounding schools in British Columbia.

    PubMed

    Black, Jennifer L; Day, Meghan

    2012-06-05

    The purpose of this study was to provide a descriptive profile of the availability of limited service food outlets surrounding public schools in British Columbia, Canada. Data from the 2010 Canadian Business Data Files were used to identify limited service food outlets including fast food outlets, beverage and snack food stores, delis and convenience stores. The number of food outlets within 800 metres of 1,392 public schools and the distance from schools to the nearest food outlets were assessed. Multivariate regression models examined the associations between food outlet availability and school-level characteristics. In 2010, over half of the public schools in BC (54%) were located within a 10-12 minute walk from at least one limited service food outlet. The median closest distance to a food outlet was just over 1 km (1016 m). Schools comprised of students living in densely populated urban neighbourhoods and neighbourhoods characterized by lower socio-economic status were more likely to have access to limited service food outlets within walking distance. After adjusting for school-level median family income and population density, larger schools had higher odds of exposure to food vendors compared to schools with fewer students. The availability of and proximity to limited service food outlets vary widely across schools in British Columbia and school-level characteristics are significantly associated with food outlet availability. Additional research is needed to understand how food environment exposures inside and surrounding schools impact students' attitudes, food choices and dietary quality.

  18. Oxygenator Safety Evaluation: A Focus on Connection Grip Strength and Arterial Temperature Measurement Accuracy

    PubMed Central

    Newland, Richard F.; Baker, Robert A.; Sanderson, Andrew J.; Tuble, Sigrid C.; Tully, Phil J.

    2012-01-01

    Abstract: This report describes the assessment of three specific safety-related specifications in the consideration of an alternate oxygenator; first the grip strength relationship between various oxygenator connectors and SMARxT® tubing, second, the grip strength of various biopassive tubings and an isolated SMARxT® connector, and finally, the accuracy of the arterial outlet temperature measurement. Grip strength experiments for the connections between the SMARxT® tubing and the venous reservoir outlet and the oxygenator venous inlet and oxygenator arterial outlet of the Medtronic Affinity®, Sorin Synthesis®, Sorin Primox®, and Terumo Capiox® RX25 oxygenators were performed. In addition we compared the grip strength of polyvinyl chloride, Physio®, Trillium®, Carmeda®, X-Coating®, and SMARxT® tubing. The accuracy of the integrated arterial outlet temperature probes was determined by comparing the temperatures measured by the integrated probe with a precision reference thermometer. Connector grip strength comparisons for the evaluation oxygenators with SMARxT® tubing showed significant variation between oxygenators and connections (p = .02). Evaluation of the arterial outlet showed significant variation between evaluation oxygenators, while at the venous reservoir outlet and oxygenator inlet, there were no significant differences. Grip strength comparison data for the various tubing types demonstrated a main effect for tubing type F(5, 18) = 8.01, p = .002, ηp2 = .77. Temperature accuracy measurements demonstrated that all oxygenators overread the arterial outlet temperature at 15°C, whilst at temperatures ≥25°C, all oxygenators underread the arterial outlet temperature. The integrity of SMARxT® tubing connection is influenced by the connector type, and may decline over time, highlighting the importance to not consider interchanging components of the bypass circuit as inconsequential. PMID:22893983

  19. Heat transfer probe

    DOEpatents

    Frank, Jeffrey I.; Rosengart, Axel J.; Kasza, Ken; Yu, Wenhua; Chien, Tai-Hsin; Franklin, Jeff

    2006-10-10

    Apparatuses, systems, methods, and computer code for, among other things, monitoring the health of samples such as the brain while providing local cooling or heating. A representative device is a heat transfer probe, which includes an inner channel, a tip, a concentric outer channel, a first temperature sensor, and a second temperature sensor. The inner channel is configured to transport working fluid from an inner inlet to an inner outlet. The tip is configured to receive at least a portion of the working fluid from the inner outlet. The concentric outer channel is configured to transport the working fluid from the inner outlet to an outer outlet. The first temperature sensor is coupled to the tip, and the second temperature sensor spaced apart from the first temperature sensor.

  20. Control methods and systems for indirect evaporative coolers

    DOEpatents

    Woods, Jason; Kozubal, Erik

    2015-09-22

    A control method for operating an indirect evaporative cooler to control temperature and humidity. The method includes operating an airflow control device to provide supply air at a flow rate to a liquid desiccant dehumidifier. The supply air flows through the dehumidifier and an indirect evaporative cooler prior to exiting an outlet into a space. The method includes operating a pump to provide liquid desiccant to the liquid desiccant dehumidifier and sensing a temperature of an airstream at the outlet of the indirect evaporative cooler. The method includes comparing the temperature of the airstream at the outlet to a setpoint temperature at the outlet and controlling the pump to set the flow rate of the liquid desiccant. The method includes sensing space temperature, comparing the space temperature with a setpoint temperature, and controlling the airflow control device to set the flow rate of the supply air based on the comparison.

  1. Temporal and spatial dispersion of human body temperature during deep hypothermia.

    PubMed

    Opatz, O; Trippel, T; Lochner, A; Werner, A; Stahn, A; Steinach, M; Lenk, J; Kuppe, H; Gunga, H C

    2013-11-01

    Clinical temperature management remains challenging. Choosing the right sensor location to determine the core body temperature is a particular matter of academic and clinical debate. This study aimed to investigate the relationship of measured temperatures at different sites during surgery in deep hypothermic patients. In this prospective single-centre study, we studied 24 patients undergoing cardiothoracic surgery: 12 in normothermia, 3 in mild, and 9 in deep hypothermia. Temperature recordings of a non-invasive heat flux sensor at the forehead were compared with the arterial outlet temperature of a heart-lung machine, with the temperature on a conventional vesical bladder thermistor and, for patients undergoing deep hypothermia, with oesophageal temperature. Using a linear model for sensor comparison, the arterial outlet sensor showed a difference among the other sensor positions between -0.54 and -1.12°C. The 95% confidence interval ranged between 7.06 and 8.82°C for the upper limit and -8.14 and -10.62°C for the lower limit. Because of the hysteretic shape, the curves were divided into phases and fitted into a non-linear model according to time and placement of the sensors. During cooling and warming phases, a quadratic relationship could be observed among arterial, oesophageal, vesical, and cranial temperature recordings, with coefficients of determination ranging between 0.95 and 0.98 (standard errors of the estimate 0.69-1.12°C). We suggest that measured surrogate temperatures as indices of the cerebral temperature (e.g. vesical bladder temperature) should be interpreted with respect to the temporal and spatial dispersion during cooling and rewarming phases.

  2. Simulated Altitude Performance of Combustor of Westinghouse 19XB-1 Jet-Propulsion Engine

    NASA Technical Reports Server (NTRS)

    Childs, J. Howard; McCafferty, Richard J.

    1948-01-01

    A 19XB-1 combustor was operated under conditions simulating zero-ram operation of the 19XB-1 turbojet engine at various altitudes and engine speeds. The combustion efficiencies and the altitude operational limits were determined; data were also obtained on the character of the combustion, the pressure drop through the combustor, and the combustor-outlet temperature and velocity profiles. At altitudes about 10,000 feet below the operational limits, the flames were yellow and steady and the temperature rise through the combustor increased with fuel-air ratio throughout the range of fuel-air ratios investigated. At altitudes near the operational limits, the flames were blue and flickering and the combustor was sluggish in its response to changes in fuel flow. At these high altitudes, the temperature rise through the combustor increased very slowly as the fuel flow was increased and attained a maximum at a fuel-air ratio much leaner than the over-all stoichiometric; further increases in fuel flow resulted in decreased values of combustor temperature rise and increased resonance until a rich-limit blow-out occurred. The approximate operational ceiling of the engine as determined by the combustor, using AN-F-28, Amendment-3, fuel, was 30,400 feet at a simulated engine speed of 7500 rpm and increased as the engine speed was increased. At an engine speed of 16,000 rpm, the operational ceiling was approximately 48,000 feet. Throughout the range of simulated altitudes and engine speeds investigated, the combustion efficiency increased with increasing engine speed and with decreasing altitude. The combustion efficiency varied from over 99 percent at operating conditions simulating high engine speed and low altitude operation to less than 50 percent at conditions simulating operation at altitudes near the operational limits. The isothermal total pressure drop through the combustor was 1.82 times as great as the inlet dynamic pressure. As expected from theoretical considerations, a straight-line correlation was obtained when the ratio of the combustor total pressure drop to the combustor-inlet dynamic pressure was plotted as a function of the ratio of the combustor-inlet air density to the combustor-outlet gas density. The combustor-outlet temperature profiles were, in general, more uniform for runs in which the temperature rise was low and the combustion efficiency was high. Inspection of the combustor basket after 36 hours of operation showed very little deterioration and no appreciable carbon deposits.

  3. Sea ice breakup and marine melt of a retreating tidewater outlet glacier in northeast Greenland (81°N).

    PubMed

    Bendtsen, Jørgen; Mortensen, John; Lennert, Kunuk; K Ehn, Jens; Boone, Wieter; Galindo, Virginie; Hu, Yu-Bin; Dmitrenko, Igor A; Kirillov, Sergei A; Kjeldsen, Kristian K; Kristoffersen, Yngve; G Barber, David; Rysgaard, Søren

    2017-07-10

    Rising temperatures in the Arctic cause accelerated mass loss from the Greenland Ice Sheet and reduced sea ice cover. Tidewater outlet glaciers represent direct connections between glaciers and the ocean where melt rates at the ice-ocean interface are influenced by ocean temperature and circulation. However, few measurements exist near outlet glaciers from the northern coast towards the Arctic Ocean that has remained nearly permanently ice covered. Here we present hydrographic measurements along the terminus of a major retreating tidewater outlet glacier from Flade Isblink Ice Cap. We show that the region is characterized by a relatively large change of the seasonal freshwater content, corresponding to ~2 m of freshwater, and that solar heating during the short open water period results in surface layer temperatures above 1 °C. Observations of temperature and salinity supported that the outlet glacier is a floating ice shelf with near-glacial subsurface temperatures at the freezing point. Melting from the surface layer significantly influenced the ice foot morphology of the glacier terminus. Hence, melting of the tidewater outlet glacier was found to be critically dependent on the retreat of sea ice adjacent to the terminus and the duration of open water.

  4. Nuclear reactor

    DOEpatents

    Yant, Howard W.; Stinebiser, Karl W.; Anzur, Gregory C.

    1977-01-01

    A nuclear reactor, particularly a liquid-metal breeder reactor, whose upper internals include outlet modules for channeling the liquid-metal coolant from selected areas of the outlet of the core vertically to the outlet plenum. The modules are composed of a highly-refractory, high corrosion-resistant alloy, for example, INCONEL-718. Each module is disposed to confine and channel generally vertically the coolant emitted from a subplurality of core-component assemblies. Each module has a grid with openings, each opening disposed to receive the coolant from an assembly of the subplurality. The grid in addition serves as a holdown for the assemblies of the corresponding subplurality preventing their excessive ejection upwardly from the core. In the region directly over the core the outlet modules are of such peripheral form that they nest forming a continuum over the core-component assemblies whose outlet coolant they confine. Each subassembly includes a chimney which confines the coolant emitted by its corresponding subassemblies to generally vertical flow between the outlet of the core and the outlet plenum. Each subplurality of assemblies whose emitted coolant is confined by an outlet module includes assemblies which emit lower-temperature coolant, for example, a control-rod assembly, or fertile assemblies, and assemblies which emit coolant of substantially higher temperature, for example, fuel-rod assemblies. The coolants of different temperatures are mixed in the chimneys reducing the effect of stripping (hot-cold temperature fluctuations) on the remainder of the upper internals which are composed typically of AISI-304 or AISI-316 stainless steel.

  5. 40 CFR Table 1 to Subpart Hhhhh of... - Emission Limits and Work Practice Standards for Process Vessels

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants... to a condenser that reduces the outlet gas temperature to: <10 °C if the process vessel contains HAP...

  6. Spray Drying of Mosambi Juice in Lab

    NASA Astrophysics Data System (ADS)

    Singh, S. V.; Verma, A.

    2014-01-01

    The studies on spray drying of mosambi juice were carried out with Laboratory spray dryer set-up (LSD-48 MINI SPRAY DRYER-JISL). Inlet and outlet air temperature and maltodextrin (drying agent) concentration was taken as variable parameters. Experiments were conducted by using 110 °C to 140 °C inlet air temperature, 60 °C to 70 °C outlet air temperature and 5-7 % maltodextrin concentration. The free flow powder of mosambi juice was obtained with 7 % maltodextrin at 140 °C inlet air temperature and 60 °C outlet air temperature. Fresh and reconstituted juices were evaluated for vitamin C, titrable acidity and sensory characteristics. The reconstituted juice was found slightly acceptable by taste panel.

  7. Investigation and optimization of the depth of flue gas heat recovery in surface heat exchangers

    NASA Astrophysics Data System (ADS)

    Bespalov, V. V.; Bespalov, V. I.; Melnikov, D. V.

    2017-09-01

    Economic issues associated with designing deep flue gas heat recovery units for natural gas-fired boilers are examined. The governing parameter affecting the performance and cost of surface-type condensing heat recovery heat exchangers is the heat transfer surface area. When firing natural gas, the heat recovery depth depends on the flue gas temperature at the condenser outlet and determines the amount of condensed water vapor. The effect of the outlet flue gas temperature in a heat recovery heat exchanger on the additionally recovered heat power is studied. A correlation has been derived enabling one to determine the best heat recovery depth (or the final cooling temperature) maximizing the anticipated reduced annual profit of a power enterprise from implementation of energy-saving measures. Results of optimization are presented for a surface-type condensing gas-air plate heat recovery heat exchanger for the climatic conditions and the economic situation in Tomsk. The predictions demonstrate that it is economically feasible to design similar heat recovery heat exchangers for a flue gas outlet temperature of 10°C. In this case, the payback period for the investment in the heat recovery heat exchanger will be 1.5 years. The effect of various factors on the optimal outlet flue gas temperature was analyzed. Most climatic, economical, or technological factors have a minor effect on the best outlet temperature, which remains between 5 and 20°C when varying the affecting factors. The derived correlation enables us to preliminary estimate the outlet (final) flue gas temperature that should be used in designing the heat transfer surface of a heat recovery heat exchanger for a gas-fired boiler as applied to the specific climatic conditions.

  8. Altitude Investigation of Gas Temperature Distribution at Turbine of Three Similar Axial-Flow Turbojet Engines

    NASA Technical Reports Server (NTRS)

    Prince, W.R.; Schulze, F.W.

    1952-01-01

    An investigation of the effect of inlet pressure, corrected engine speed, and turbine temperature level on turbine-inlet gas temperature distributions was conducted on a J40-WE-6, interim J40-WE-6, and prototype J40-WE-8 turbojet engine in the altitude wind tunnel at the NAC.4 Lewis laboratory. The engines were investigated over a range of simulated pressure altitudes from 15,000 to 55,000 feet, flight Mach numbers from 0.12 to 0.64, and corrected engine speeds from 7198 to 8026 rpm, The gas temperature distribution at the turbine of the three engines over the range of operating conditions investigated was considered satisfactory from the standpoint of desired temperature distribution with one exception - the distribution for the J40-WE-6 engine indicated a trend with decreasing engine-inlet pressure for the temperature to exceed the desired in the region of the blade hub. Installation of a compressor-outlet mixer vane assembly remedied this undesirable temperature distribution, The experimental data have shown that turbine-inlet temperature distributions are influenced in the expected manner by changes in compressor-outlet pressure or mass-flow distribution and by changes in combustor hole-area distribution. The similarity between turbine-inlet and turbine-outlet temperature distribution indicated only a small shift in temperature distribution imposed by the turbine rotors. The attainable jet thrusts of the three engines were influenced in different degrees and directions by changes in temperature distributions with change in engine-inlet pressure. Inability to match the desired temperature distribution resulted, for the J40-WE-6 engine, in an 11-percent thrust loss based on an average turbine-inlet temperature of 1500 F at an engine-inlet pressure of 500 pounds per square foot absolute. Departure from the desired temperature distribution in the Slade tip region results, for the prototype J40-WE-8 engine, in an attainable thrust increase of 3 to 4 percent as compared with that obtained if tip-region temperature limitations were observed.

  9. Structural Design Considerations for Tubular Power Tower Receivers Operating at 650 Degrees C: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neises, T. W.; Wagner, M. J.; Gray, A. K.

    Research of advanced power cycles has shown supercritical carbon dioxide power cycles may have thermal efficiency benefits relative to steam cycles at temperatures around 500 - 700 degrees C. To realize these benefits for CSP, it is necessary to increase the maximum outlet temperature of current tower designs. Research at NREL is investigating a concept that uses high-pressure supercritical carbon dioxide as the heat transfer fluid to achieve a 650 degrees C receiver outlet temperature. At these operating conditions, creep becomes an important factor in the design of a tubular receiver and contemporary design assumptions for both solar and traditionalmore » boiler applications must be revisited and revised. This paper discusses lessons learned for high-pressure, high-temperature tubular receiver design. An analysis of a simplified receiver tube is discussed, and the results show the limiting stress mechanisms in the tube and the impact on the maximum allowable flux as design parameters vary. Results of this preliminary analysis indicate an underlying trade-off between tube thickness and the maximum allowable flux on the tube. Future work will expand the scope of design variables considered and attempt to optimize the design based on cost and performance metrics.« less

  10. Examining the interaction between food outlets and outdoor food advertisements with primary school food environments.

    PubMed

    Walton, Mat; Pearce, Jamie; Day, Peter

    2009-09-01

    Schools are commonly seen as a site of intervention to improve children's nutrition, and prevent excess weight gain. Schools may have limited influence over children's diets; however, with home and community environments also exerting an influence within schools. This study considered the environment of food outlets and outdoor food advertisements surrounding four case study primary schools in New Zealand, and the impact of that external environment on within-school food environments. The shortest travel route between school and home addresses, and the number of food outlets and advertisements passed on that route, was calculated for each student. Interviews with school management were conducted. The schools with a higher percentage of students passing food outlets and advertisements considered that their presence impacted on efforts within schools to improve the food environment. Limiting students' exposure to food outlets and outdoor food adverts through travel route planning, reducing advertising, or limiting the location of food outlets surrounding schools could be explored as intervention options to support schools in promoting nutrition.

  11. Improved algorithms in the CE-QUAL-W2 water-quality model for blending dam releases to meet downstream water-temperature targets

    USGS Publications Warehouse

    Rounds, Stewart A.; Buccola, Norman L.

    2015-01-01

    Water-quality models allow water resource professionals to examine conditions under an almost unlimited variety of potential future scenarios. The two-dimensional (longitudinal, vertical) water-quality model CE-QUAL-W2, version 3.7, was enhanced and augmented with new features to help dam operators and managers explore and optimize potential solutions for temperature management downstream of thermally stratified reservoirs. Such temperature management often is accomplished by blending releases from multiple dam outlets that access water of different temperatures at different depths. The modified blending algorithm in version 3.7 of CE-QUAL-W2 allows the user to specify a time-series of target release temperatures, designate from 2 to 10 floating or fixed-elevation outlets for blending, impose minimum and maximum head and flow constraints for any blended outlet, and set priority designations for each outlet that allow the model to choose which outlets to use and how to balance releases among them. The modified model was tested with a variety of examples and against a previously calibrated model of Detroit Lake on the North Santiam River in northwestern Oregon, and the results compared well. These updates to the blending algorithms will allow more complicated dam-operation scenarios to be evaluated somewhat automatically with the model, with decreased need for multiple model runs or preprocessing of model inputs to fully characterize the operational constraints.

  12. Performance of Inductors Attached to a Galvanizing Bath

    NASA Astrophysics Data System (ADS)

    Zhou, Xinping; Yuan, Shuo; Liu, Chi; Yang, Peng; Qian, Chaoqun; Song, Bao

    2013-12-01

    By taking a galvanizing bath with inductors from an Iron and Steel Co., Ltd as an example, the distributions of Lorentz force and generated heat in the inductor are simulated. As a result, the zinc flow and the temperature distribution driven by the Lorentz force and the generated heat in the inductor of a galvanizing bath are simulated numerically, and their characteristics are analyzed. The relationship of the surface-weighted average velocity at the outlet and the temperature difference between the inlet and the outlet and the effective power for the inductor is studied. Results show that with an increase in effective power for the inductor, the surface-weighted average velocity at the outlet and the temperature difference between the inlet and the outlet increase gradually. We envisage this work to lay a foundation for the study of the performance of the galvanizing bath in future.

  13. 40 CFR 63.490 - Batch front-end process vents-performance test methods and procedures to determine compliance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... temperature is 20 °C. Cj = Average inlet or outlet concentration of TOC or sample organic HAP component j of...) (kg/gm) (min/hr), where standard temperature is 20 °C. Cj = Inlet or outlet concentration of TOC or...

  14. 40 CFR 63.490 - Batch front-end process vents-performance test methods and procedures to determine compliance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... temperature is 20 °C. Cj = Average inlet or outlet concentration of TOC or sample organic HAP component j of...) (kg/gm) (min/hr), where standard temperature is 20 °C. Cj = Inlet or outlet concentration of TOC or...

  15. 40 CFR 63.490 - Batch front-end process vents-performance test methods and procedures to determine compliance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... temperature is 20 °C. Cj = Average inlet or outlet concentration of TOC or sample organic HAP component j of...) (kg/gm) (min/hr), where standard temperature is 20 °C. Cj = Inlet or outlet concentration of TOC or...

  16. Pressure, temperature and density drops along supercritical fluid chromatography columns. I. Experimental results for neat carbon dioxide and columns packed with 3- and 5-micron particles.

    PubMed

    Poe, Donald P; Veit, Devon; Ranger, Megan; Kaczmarski, Krzysztof; Tarafder, Abhijit; Guiochon, Georges

    2012-08-10

    The pressure drop and temperature drop on columns packed with 3- and 5-micron particles were measured using neat CO(2) at a flow rate of 5 mL/min, at temperatures from 20°C to 100°C, and outlet pressures from 80 to 300 bar. The density drop was calculated based on the temperature and pressure at the column inlet and outlet. The columns were suspended in a circulating air bath either bare or covered with foam insulation. The results show that the pressure drop depends on the outlet pressure, the operating temperature, and the thermal environment. A temperature drop was observed for all conditions studied. The temperature drop was relatively small (less than 3°C) for combinations of low temperature and high pressure. Larger temperature drops and density drops occurred at higher temperatures and low to moderate pressures. Covering the column with thermal insulation resulted in larger temperature drops and corresponding smaller density drops. At 20°C the temperature drop was never more than a few degrees. The largest temperature drops occurred for both columns when insulated at 80°C and 80 bar, reaching a maximum value of 21°C for the 5-micron column, and 26°C for the 3-micron column. For an adiabatic column, the temperature drop depends on the pressure drop, the thermal expansion coefficient, and the density and the heat capacity of the mobile phase fluid, and can be described by a simple mathematical relationship. For a fixed operating temperature and outlet pressure, the temperature drop increases monotonically with the pressure drop. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. CFD Analysis of Upper Plenum Flow for a Sodium-Cooled Small Modular Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kraus, A.; Hu, R.

    2015-01-01

    Upper plenum flow behavior is important for many operational and safety issues in sodium fast reactors. The Prototype Gen-IV Sodium Fast Reactor (PGSFR), a pool-type, 150 MWe output power design, was used as a reference case for a detailed characterization of upper plenum flow for normal operating conditions. Computational Fluid Dynamics (CFD) simulation was utilized with detailed geometric modeling of major structures. Core outlet conditions based on prior system-level calculations were mapped to approximate the outlet temperatures and flow rates for each core assembly. Core outlet flow was found to largely bypass the Upper Internal Structures (UIS). Flow curves overmore » the shield and circulates within the pool before exiting the plenum. Cross-flows and temperatures were evaluated near the core outlet, leading to a proposed height for the core outlet thermocouples to ensure accurate assembly-specific temperature readings. A passive scalar was used to evaluate fluid residence time from core outlet to IHX inlet, which can be used to assess the applicability of various methods for monitoring fuel failure. Additionally, the gas entrainment likelihood was assessed based on the CFD simulation results. Based on the evaluation of velocity gradients and turbulent kinetic energies and the available gas entrainment criteria in the literature, it was concluded that significant gas entrainment is unlikely for the current PGSFR design.« less

  18. Temperature of gas delivered from ventilators.

    PubMed

    Chikata, Yusuke; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji

    2013-01-01

    Although heated humidifiers (HHs) are the most efficient humidifying device for mechanical ventilation, some HHs do not provide sufficient humidification when the inlet temperature to the water chamber is high. Because portable and home-care ventilators use turbines, blowers, pistons, or compressors to inhale in ambient air, they may have higher gas temperature than ventilators with piping systems. We carried out a bench study to investigate the temperature of gas delivered from portable and home-care ventilators, including the effects of distance from ventilator outlet, fraction of inspiratory oxygen (FIO2), and minute volume (MV). We evaluated five ventilators equipped with turbine, blower, piston, or compressor system. Ambient air temperature was adjusted to 24°C ± 0.5°C, and ventilation was set at FIO2 0.21, 0.6, and 1.0, at MV 5 and 10 L/min. We analyzed gas temperature at 0, 40, 80, and 120 cm from ventilator outlet and altered ventilator settings. While temperature varied according to ventilators, the outlet gas temperature of ventilators became stable after, at the most, 5 h. Gas temperature was 34.3°C ± 3.9°C at the ventilator outlet, 29.5°C ± 2.2°C after 40 cm, 25.4°C ± 1.2°C after 80 cm and 25.1°C ± 1.2°C after 120 cm (P < 0.01). FIO2 and MV did not affect gas temperature. Gas delivered from portable and home-care ventilator was not too hot to induce heated humidifier malfunctioning. Gas soon declined when passing through the limb.

  19. Direct-contact closed-loop heat exchanger

    DOEpatents

    Berry, Gregory F.; Minkov, Vladimir; Petrick, Michael

    1984-01-01

    A high temperature heat exchanger with a closed loop and a heat transfer liquid within the loop, the closed loop having a first horizontal channel with inlet and outlet means for providing direct contact of a first fluid at a first temperature with the heat transfer liquid, a second horizontal channel with inlet and outlet means for providing direct contact of a second fluid at a second temperature with the heat transfer liquid, and means for circulating the heat transfer liquid.

  20. Event-based stormwater management pond runoff temperature model

    NASA Astrophysics Data System (ADS)

    Sabouri, F.; Gharabaghi, B.; Sattar, A. M. A.; Thompson, A. M.

    2016-09-01

    Stormwater management wet ponds are generally very shallow and hence can significantly increase (about 5.4 °C on average in this study) runoff temperatures in summer months, which adversely affects receiving urban stream ecosystems. This study uses gene expression programming (GEP) and artificial neural networks (ANN) modeling techniques to advance our knowledge of the key factors governing thermal enrichment effects of stormwater ponds. The models developed in this study build upon and compliment the ANN model developed by Sabouri et al. (2013) that predicts the catchment event mean runoff temperature entering the pond as a function of event climatic and catchment characteristic parameters. The key factors that control pond outlet runoff temperature, include: (1) Upland Catchment Parameters (catchment drainage area and event mean runoff temperature inflow to the pond); (2) Climatic Parameters (rainfall depth, event mean air temperature, and pond initial water temperature); and (3) Pond Design Parameters (pond length-to-width ratio, pond surface area, pond average depth, and pond outlet depth). We used monitoring data for three summers from 2009 to 2011 in four stormwater management ponds, located in the cities of Guelph and Kitchener, Ontario, Canada to develop the models. The prediction uncertainties of the developed ANN and GEP models for the case study sites are around 0.4% and 1.7% of the median value. Sensitivity analysis of the trained models indicates that the thermal enrichment of the pond outlet runoff is inversely proportional to pond length-to-width ratio, pond outlet depth, and directly proportional to event runoff volume, event mean pond inflow runoff temperature, and pond initial water temperature.

  1. Development of a prototype automatic controller for liquid cooling garment inlet temperature

    NASA Technical Reports Server (NTRS)

    Weaver, C. S.; Webbon, B. W.; Montgomery, L. D.

    1982-01-01

    The development of a computer control of a liquid cooled garment (LCG) inlet temperature is descirbed. An adaptive model of the LCG is used to predict the heat-removal rates for various inlet temperatures. An experimental system that contains a microcomputer was constructed. The LCG inlet and outlet temperatures and the heat exchanger outlet temperature form the inputs to the computer. The adaptive model prediction method of control is successful during tests where the inlet temperature is automatically chosen by the computer. It is concluded that the program can be implemented in a microprocessor of a size that is practical for a life support back-pack.

  2. Direct-contact closed-loop heat exchanger

    DOEpatents

    Berry, G.F.; Minkov, V.; Petrick, M.

    1981-11-02

    A high temperature heat exchanger is disclosed which has a closed loop and a heat transfer liquid within the loop, the closed loop having a first horizontal channel with inlet and outlet means for providing direct contact of a first fluid at a first temperature with the heat transfer liquid, a second horizontal channel with inlet and outlet means for providing direct contact of a second fluid at a second temperature with the heat transfer liquid, and means for circulating the heat transfer liquid.

  3. Discussion on Boiler Efficiency Correction Method with Low Temperature Economizer-Air Heater System

    NASA Astrophysics Data System (ADS)

    Ke, Liu; Xing-sen, Yang; Fan-jun, Hou; Zhi-hong, Hu

    2017-05-01

    This paper pointed out that it is wrong to take the outlet flue gas temperature of low temperature economizer as exhaust gas temperature in boiler efficiency calculation based on GB10184-1988. What’s more, this paper proposed a new correction method, which decomposed low temperature economizer-air heater system into two hypothetical parts of air preheater and pre condensed water heater and take the outlet equivalent gas temperature of air preheater as exhaust gas temperature in boiler efficiency calculation. This method makes the boiler efficiency calculation more concise, with no air heater correction. It has a positive reference value to deal with this kind of problem correctly.

  4. Microchannel heat sink assembly

    DOEpatents

    Bonde, Wayne L.; Contolini, Robert J.

    1992-01-01

    The present invention provides a microchannel heat sink with a thermal range from cryogenic temperatures to several hundred degrees centigrade. The heat sink can be used with a variety of fluids, such as cryogenic or corrosive fluids, and can be operated at a high pressure. The heat sink comprises a microchannel layer preferably formed of silicon, and a manifold layer preferably formed of glass. The manifold layer comprises an inlet groove and outlet groove which define an inlet manifold and an outlet manifold. The inlet manifold delivers coolant to the inlet section of the microchannels, and the outlet manifold receives coolant from the outlet section of the microchannels. In one embodiment, the manifold layer comprises an inlet hole extending through the manifold layer to the inlet manifold, and an outlet hole extending through the manifold layer to the outlet manifold. Coolant is supplied to the heat sink through a conduit assembly connected to the heat sink. A resilient seal, such as a gasket or an O-ring, is disposed between the conduit and the hole in the heat sink in order to provide a watetight seal. In other embodiments, the conduit assembly may comprise a metal tube which is connected to the heat sink by a soft solder. In still other embodiments, the heat sink may comprise inlet and outlet nipples. The present invention has application in supercomputers, integrated circuits and other electronic devices, and is suitable for cooling materials to superconducting temperatures.

  5. Alcohol outlet density and assault: a spatial analysis.

    PubMed

    Livingston, Michael

    2008-04-01

    A large number of studies have found links between alcohol outlet densities and assault rates in local areas. This study tests a variety of specifications of this link, focusing in particular on the possibility of a non-linear relationship. Cross-sectional data on police-recorded assaults during high alcohol hours, liquor outlets and socio-demographic characteristics were obtained for 223 postcodes in Melbourne, Australia. These data were used to construct a series of models testing the nature of the relationship between alcohol outlet density and assault, while controlling for socio-demographic factors and spatial auto-correlation. Four types of relationship were examined: a normal linear relationship between outlet density and assault, a non-linear relationship with potential threshold or saturation densities, a relationship mediated by the socio-economic status of the neighbourhood and a relationship which takes into account the effect of outlets in surrounding neighbourhoods. The model positing non-linear relationships between outlet density and assaults was found to fit the data most effectively. An increasing accelerating effect for the density of hotel (pub) licences was found, suggesting a plausible upper limit for these licences in Melbourne postcodes. The study finds positive relationships between outlet density and assault rates and provides evidence that this relationship is non-linear and thus has critical values at which licensing policy-makers can impose density limits.

  6. High temperature solar receiver

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The development of a high temperature solar thermal receiver is described. A prototype receiver and associated test support (auxiliary) hardware was fabricated. Shakedown and initial performance tests of the prototype receiver were performed. Maximum outlet temperatures of 1600 F were achieved at 100% solar (70-75 kW) input power with 900 F inlet temperatures and a subsequent testing was concluded by a 2550 F outlet run. The window retaining assembly was modified to improve its tolerance for thermal distortion of the flanges. It is shown that cost effective receiver designs can be implemented within the framework of present materials technology.

  7. The effect on engine performance of change in jacket-water outlet temperature

    NASA Technical Reports Server (NTRS)

    Garlock, E A; Ellis, Greer

    1933-01-01

    Tests made on a Curtiss D-12 engine in the Altitude Laboratory at the Bureau of Standards show the following effects on engine performance of change in jacket-water outlet temperature: 1) Friction at all altitudes is a linear function of the jacket-water temperature, decreasing with increasing temperature. 2) The brake horsepower below an altitude of about 9,000 feet decreases, and at higher altitudes increases, with jacket-water temperature. 3) The brake specific fuel consumption tends to decrease, at all altitudes, with increasing jacket-water temperature. 4) The percentage change in brake power output is roughly equal to the algebraic sum of the percentage change in volumetric efficiency and mechanical efficiency.

  8. Cooling Performance Analysis of ThePrimary Cooling System ReactorTRIGA-2000Bandung

    NASA Astrophysics Data System (ADS)

    Irianto, I. D.; Dibyo, S.; Bakhri, S.; Sunaryo, G. R.

    2018-02-01

    The conversion of reactor fuel type will affect the heat transfer process resulting from the reactor core to the cooling system. This conversion resulted in changes to the cooling system performance and parameters of operation and design of key components of the reactor coolant system, especially the primary cooling system. The calculation of the operating parameters of the primary cooling system of the reactor TRIGA 2000 Bandung is done using ChemCad Package 6.1.4. The calculation of the operating parameters of the cooling system is based on mass and energy balance in each coolant flow path and unit components. Output calculation is the temperature, pressure and flow rate of the coolant used in the cooling process. The results of a simulation of the performance of the primary cooling system indicate that if the primary cooling system operates with a single pump or coolant mass flow rate of 60 kg/s, it will obtain the reactor inlet and outlet temperature respectively 32.2 °C and 40.2 °C. But if it operates with two pumps with a capacity of 75% or coolant mass flow rate of 90 kg/s, the obtained reactor inlet, and outlet temperature respectively 32.9 °C and 38.2 °C. Both models are qualified as a primary coolant for the primary coolant temperature is still below the permitted limit is 49.0 °C.

  9. Effects of Outlets on Cracking Risk and Integral Stability of Super-High Arch Dams

    PubMed Central

    Hu, Hang

    2014-01-01

    In this paper, case study on outlet cracking is first conducted for the Goupitan and Xiaowan arch dams. A nonlinear FEM method is then implemented to study effects of the outlets on integral stability of the Xiluodu arch dam under two loading conditions, i.e., normal loading and overloading conditions. On the basis of the case study and the numerical modelling, the outlet cracking mechanism, risk, and corresponding reinforcement measures are discussed. Furthermore, the numerical simulation reveals that (1) under the normal loading conditions, the optimal distribution of the outlets will contribute to the tensile stress release in the local zone of the dam stream surface and decrease the outlet cracking risk during the operation period. (2) Under the overloading conditions, the cracks initiate around the outlets, then propagate along the horizontal direction, and finally coalesce with those in adjacent outlets, where the yield zone of the dam has a shape of butterfly. Throughout this study, a dam outlet cracking risk control and reinforcement principle is proposed to optimize the outlet design, select the appropriate concrete material, strengthen the temperature control during construction period, design reasonable impounding scheme, and repair the cracks according to their classification. PMID:25152907

  10. Inequalities in tobacco outlet density by race, ethnicity and socioeconomic status, 2012, USA: results from the ASPiRE Study.

    PubMed

    Lee, Joseph G L; Sun, Dennis L; Schleicher, Nina M; Ribisl, Kurt M; Luke, Douglas A; Henriksen, Lisa

    2017-05-01

    Evidence of racial/ethnic inequalities in tobacco outlet density is limited by: (1) reliance on studies from single counties or states, (2) limited attention to spatial dependence, and (3) an unclear theory-based relationship between neighbourhood composition and tobacco outlet density. In 97 counties from the contiguous USA, we calculated the 2012 density of likely tobacco outlets (N=90 407), defined as tobacco outlets per 1000 population in census tracts (n=17 667). We used 2 spatial regression techniques, (1) a spatial errors approach in GeoDa software and (2) fitting a covariance function to the errors using a distance matrix of all tract centroids. We examined density as a function of race, ethnicity, income and 2 indicators identified from city planning literature to indicate neighbourhood stability (vacant housing, renter-occupied housing). The average density was 1.3 tobacco outlets per 1000 persons. Both spatial regression approaches yielded similar results. In unadjusted models, tobacco outlet density was positively associated with the proportion of black residents and negatively associated with the proportion of Asian residents, white residents and median household income. There was no association with the proportion of Hispanic residents. Indicators of neighbourhood stability explained the disproportionate density associated with black residential composition, but inequalities by income persisted in multivariable models. Data from a large sample of US counties and results from 2 techniques to address spatial dependence strengthen evidence of inequalities in tobacco outlet density by race and income. Further research is needed to understand the underlying mechanisms in order to strengthen interventions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Effects of radiofrequency probe application on irrigation fluid temperature in the wrist joint.

    PubMed

    Sotereanos, Dean G; Darlis, Nickolaos A; Kokkalis, Zinon T; Zanaros, George; Altman, Gregory T; Miller, Mark Carl

    2009-12-01

    Radiofrequency (RF) probes used in wrist arthroscopy may raise joint fluid temperature, increasing the risk of capsular and ligamentous damage. The purposes of the current study were to measure joint fluid temperature during wrist arthroscopy with the use of RF probes, and to determine whether using an outlet portal will reduce the maximum temperature. We performed wrist arthroscopy on 8 cadaveric arms. Ablation and coagulation cycles using RF probe were performed at documented locations within the joint. This was done for 60-second intervals on both the radial and ulnar side of the wrist, to mimic clinical practice. We used 4 fiberoptic phosphorescent probes to measure temperature (radial, ulnar, inflow-tube, and outflow-tube probes) and measured joint fluid temperature with and without outflow. There was a significant difference between wrists with and without outflow when examining maximum ablation temperatures (p < .002). All specimens showed higher maximum and average ablation temperatures without outflow. Maximum joint temperatures, greater than 60 degrees C, were observed in only no-outflow conditions. In performing RF ablation during wrist arthroscopy, the use of an outlet portal reduces the joint fluid temperature. Without an outlet portal, maximum temperatures can exceed desirable levels when using ablation; such temperatures have the potential to damage adjacent tissues. It is useful to maintain adequate outflow when using the radiofrequency probes during wrist arthroscopy.

  12. Effect of distributor on performance of a continuous fluidized bed dryer

    NASA Astrophysics Data System (ADS)

    Yogendrasasidhar, D.; Srinivas, G.; Pydi Setty, Y.

    2018-03-01

    Proper gas distribution is very important in fluidized bed drying in industrial practice. Improper distribution of gas may lead to non-idealities like channeling, short circuiting and accumulation which gives rise to non-uniform quality of dried product. Gas distribution depends on the distributor plate used. Gas distribution mainly depends on orifice diameter, number of orifices and opening area of the distributor plate. Small orifice diameter leads to clogging, and a large orifice diameter gives uneven distribution of gas. The present work involves experimental studies using different distributor plates and simulation studies using ASPEN PLUS steady state simulator. The effect of various parameters such as orifice diameter, number of orifices and the opening area of the distributor plate on the performance of fluidized bed dryer have been studied through simulation and experimentation. Simulations were carried out (i) with increasing air inlet temperature to study the characteristics of solid temperature and moisture in outlet (ii) with increasing orifice diameter and (iii) with increase in number orifices to study the solid outlet temperature profiles. It can be observed from the simulation that, an increase in orifice diameter and number orifices increases solid outlet temperature upto certain condition and then after there is no effect with further increase. Experiments were carried out with increasing opening area (3.4 to 42%) in the form of increasing orifice diameter keeping the number of orifices constant and increasing number of orifices of the distributor plate keeping the orifice diameter constant. It can be seen that the drying rate and solid outlet temperature increase upto certain condition and then after with further increase in the orifice diameter and number of orifices, the change in the drying rate and solid outlet temperature observed is little. The optimum values of orifice diameter and number of orifices from experimentation are found to be 5 mm and 60 (22% opening area).

  13. Microchannel heat sink assembly

    DOEpatents

    Bonde, W.L.; Contolini, R.J.

    1992-03-24

    The present invention provides a microchannel heat sink with a thermal range from cryogenic temperatures to several hundred degrees centigrade. The heat sink can be used with a variety of fluids, such as cryogenic or corrosive fluids, and can be operated at a high pressure. The heat sink comprises a microchannel layer preferably formed of silicon, and a manifold layer preferably formed of glass. The manifold layer comprises an inlet groove and outlet groove which define an inlet manifold and an outlet manifold. The inlet manifold delivers coolant to the inlet section of the microchannels, and the outlet manifold receives coolant from the outlet section of the microchannels. In one embodiment, the manifold layer comprises an inlet hole extending through the manifold layer to the inlet manifold, and an outlet hole extending through the manifold layer to the outlet manifold. Coolant is supplied to the heat sink through a conduit assembly connected to the heat sink. A resilient seal, such as a gasket or an O-ring, is disposed between the conduit and the hole in the heat sink in order to provide a watertight seal. In other embodiments, the conduit assembly may comprise a metal tube which is connected to the heat sink by a soft solder. In still other embodiments, the heat sink may comprise inlet and outlet nipples. The present invention has application in supercomputers, integrated circuits and other electronic devices, and is suitable for cooling materials to superconducting temperatures. 13 figs.

  14. Reliability and mass analysis of dynamic power conversion systems with parallel of standby redundancy

    NASA Technical Reports Server (NTRS)

    Juhasz, A. J.; Bloomfield, H. S.

    1985-01-01

    A combinatorial reliability approach is used to identify potential dynamic power conversion systems for space mission applications. A reliability and mass analysis is also performed, specifically for a 100 kWe nuclear Brayton power conversion system with parallel redundancy. Although this study is done for a reactor outlet temperature of 1100K, preliminary system mass estimates are also included for reactor outlet temperatures ranging up to 1500 K.

  15. An Improved Model for a Once-through Counter-Cross-Flow Waste Heat Recovery Unit

    DTIC Science & Technology

    1983-09-01

    RAnkine Cycle Energy Recovery (RACER) system. As conceived, the RACER system will be an unfired waste heat recovery system designed to convert waste... heater to arrive at the feedwater inlet. For the given geometry and flow conditions, the model will calcu- late the water inlet temperature consistent...when given feedwater inlet temperature, steam outlet tempera- ture, operating pressure, inlet and outlet gas conditions and gas flow rate. In this

  16. 40 CFR 63.1325 - Batch process vents-performance test methods and procedures to determine compliance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Cj=Average inlet or outlet concentration of TOC or sample organic HAP component j of the gas stream...), where standard temperature is 20 °C. Cj=Inlet or outlet concentration of TOC or sample organic HAP...

  17. 40 CFR 63.1325 - Batch process vents-performance test methods and procedures to determine compliance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Cj=Average inlet or outlet concentration of TOC or sample organic HAP component j of the gas stream...), where standard temperature is 20 °C. Cj=Inlet or outlet concentration of TOC or sample organic HAP...

  18. 40 CFR 63.1325 - Batch process vents-performance test methods and procedures to determine compliance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Cj=Average inlet or outlet concentration of TOC or sample organic HAP component j of the gas stream...), where standard temperature is 20 °C. Cj=Inlet or outlet concentration of TOC or sample organic HAP...

  19. Experimentation and Modeling of Jet A Thermal Stability in a Heated Tube

    NASA Technical Reports Server (NTRS)

    Khodabandeh, Julia W.

    2005-01-01

    High performance aircraft typically use hydrocarbon fuel to regeneratively cool the airframe and engine components. As the coolant temperatures increase, the fuel may react with dissolved oxygen forming deposits that limit the regenerative cooling system performance. This study investigates the deposition of Jet A using a thermal stability experiment and computational fluid dynamics (CFD) modeling. The experimental portion of this study is performed with a high Reynolds number thermal stability (HiRets) tester in which fuel passes though an electrically heated tube and the fuel outlet temperature is held constant. If the thermal stability temperature of the fuel is exceeded, deposits form and adhere to the inside of the tube creating an insulating layer between the tube and the fuel. The HiRets tester measures the tube outer wall temperatures near the fuel outlet to report the effect of deposition occurring inside the tube. Final deposits are also estimated with a carbon burn off analysis. The CFD model was developed and used to simulate the fluid dynamics, heat transfer, chemistry, and transport of the deposit precursors. The model is calibrated to the experiment temperature results and carbon burn-off deposition results. The model results show that the dominant factor in deposition is the heated wall temperature and that most of the deposits are formed in the laminar sublayer. The models predicted a 7.0E-6 kilograms per square meter-sec deposition rate, which compared well to the carbon burn-off analysis deposition rate of 1.0E-6 kilograms per square meter-sec.

  20. Arrhenius activation energy of damage to catalase during spray-drying.

    PubMed

    Schaefer, Joachim; Lee, Geoffrey

    2015-07-15

    The inactivation of catalase during spray-drying over a range of outlet gas temperatures could be closely represented by the Arrhenius equation. From this an activation energy for damage to the catalase could be calculated. The close fit to Arrhenius suggests that the thermally-induced part of inactivation of the catalase during the complex drying and particle-formation processes takes place at constant temperature. These processes are rapid compared with the residence time of the powder in the collecting vessel of the cyclone where dried catalase is exposed to a constant temperature equal to approximately the drying gas outlet temperature. A lower activation energy after spray drying with the ultrasonic nozzle was found than with the 2-fluid nozzle under otherwise identical spray drying conditions. It is feasible that the ultrasonic nozzle when mounted in the lid of the spray dryer heats up toward the drying gas inlet temperature much more that the air-cooled 2-fluid nozzle. Calculation of the Arrhenius activation energy also showed how the stabilizing efficacy of trehalose and mannitol on the catalase varies in strength across the range of drying gas inlet and outlet temperatures examined. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Water Ingestion into Axial Flow Compressors. Part III. Experimental Results and Discussion

    DTIC Science & Technology

    1981-10-01

    total pressure, static pressure, and temperature at both compressor inlet and outlet. A United Sensor model PDC-12-G-l0-KL pitot-static pressure probe...Test Compressor inlet and outlet temperatures during water injection tests: United Sensor and Control Corp. type TK-8-CiA-36’-F Aspirate...ured utilizing standard aspirated thermocouples, namely an United Sensor and Control Corp. type TK-8-C/A-36-F. The Test Compressor out- let

  2. Technologies for Upgrading Light Water Reactor Outlet Temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel S. Wendt; Piyush Sabharwall; Vivek Utgikar

    Nuclear energy could potentially be utilized in hybrid energy systems to produce synthetic fuels and feedstocks from indigenous carbon sources such as coal and biomass. First generation nuclear hybrid energy system (NHES) technology will most likely be based on conventional light water reactors (LWRs). However, these LWRs provide thermal energy at temperatures of approximately 300°C, while the desired temperatures for many chemical processes are much higher. In order to realize the benefits of nuclear hybrid energy systems with the current LWR reactor fleets, selection and development of a complimentary temperature upgrading technology is necessary. This paper provides an initial assessmentmore » of technologies that may be well suited toward LWR outlet temperature upgrading for powering elevated temperature industrial and chemical processes during periods of off-peak power demand. Chemical heat transformers (CHTs) are a technology with the potential to meet LWR temperature upgrading requirements for NHESs. CHTs utilize chemical heat of reaction to change the temperature at which selected heat sources supply or consume thermal energy. CHTs could directly utilize LWR heat output without intermediate mechanical or electrical power conversion operations and the associated thermodynamic losses. CHT thermal characteristics are determined by selection of the chemical working pair and operating conditions. This paper discusses the chemical working pairs applicable to LWR outlet temperature upgrading and the CHT operating conditions required for providing process heat in NHES applications.« less

  3. Performance Investigation on an Ultra-compact Interstage Turbine Burner with Trapped-vortex Slot Inlet

    NASA Astrophysics Data System (ADS)

    Zhang, Hongtao; Luo, Guangqi; Guan, Lei; Zeng, Jianchen

    2017-10-01

    Ultra-Compact Combustor (UCC), which is one of mainstream design concepts of Interstage Turbine Burner (ITB), has the advantages of compact structure and high combustion efficiency. A design concept of an UCC with trapped-vortex slot inlet was proposed and numerical simulation of the stability, emissions, internal flow velocity and temperature distribution was carried out. The results indicated that the UCC with trapped-vortex slot inlet could enhance the mixing of combustion mixture and the mainstream airflow, improve the combustion efficiency, outlet temperature and the uniformity of outlet temperature field.

  4. Water chemistry, seepage investigation, streamflow, reservoir storage, and annual availability of water for the San Juan-Chama Project, northern New Mexico, 1942-2010

    USGS Publications Warehouse

    McKean, Sarah E.; Anderholm, Scott K.

    2014-01-01

    The Albuquerque Bernalillo County Water Utility Authority supplements the municipal water supply for the Albuquerque metropolitan area, in central New Mexico, with surface water diverted from the Rio Grande. The U.S. Geological Survey, in cooperation with the Albuquerque Bernalillo County Water Utility Authority, undertook this study in which water-chemistry data and historical streamflow were compiled and new water-chemistry data were collected to characterize the water chemistry and streamflow of the San Juan-Chama Project (SJCP). Characterization of streamflow included analysis of the variability of annual streamflow and comparison of the theoretical amount of water that could have been diverted into the SJCP to the actual amount of water that was diverted for the SJCP. Additionally, a seepage investigation was conducted along the channel between Azotea Tunnel Outlet and the streamflow-gaging station at Willow Creek above Heron Reservoir to estimate the magnitude of the gain or loss in streamflow resulting from groundwater interaction over the approximately 10-mile reach. Generally, surface-water chemistry varied with streamflow throughout the year. Streamflow ranged from high flow to low flow on the basis of the quantity of water diverted from the Rio Blanco, Little Navajo River, and Navajo River for the SJCP. Vertical profiles of the water temperature over the depth of the water column at Heron Reservoir indicated that the reservoir is seasonally stratified. The results from the seepage investigations indicated a small amount of loss of streamflow along the channel. Annual variability in streamflow for the SJCP was an indication of the variation in the climate parameters that interact to contribute to streamflow in the Rio Blanco, Little Navajo River, Navajo River, and Willow Creek watersheds. For most years, streamflow at Azotea Tunnel Outlet started in March and continued for approximately 3 months until the middle of July. The majority of annual streamflow at Azotea Tunnel Outlet occurred from May through June, with a median duration of slightly longer than a month. Years with higher maximum daily streamflow generally are associated with higher annual streamflow than years with lower maximum daily streamflow. The amount of water that can be diverted for the SJCP is controlled by the availability of streamflow and is limited by several factors including legal limits for diversion, limits from the SJCP infrastructure including the size of the diversion dams and tunnels, the capacity of Heron Reservoir, and operational constraints that limit when water can be diverted. The average annual streamflow at Azotea Tunnel Outlet was 94,710 acre-feet, and the annual streamflow at Azotea Tunnel Outlet was approximately 75 percent of the annual streamflow available for the SJCP. The average annual percentage of available streamflow not diverted for the SJCP was 14 percent because of structural limitations of the capacity of infrastructure, 1 percent because of limitations of the reservoir storage capacity, and 29 percent because of the limitations from operations. For most years, the annual available streamflow not diverted for unknown reasons exceeded the sum of the water not diverted because of structural, capacity, and operational limitations.

  5. Water temperature effects from simulated dam operations and structures in the Middle Fork Willamette River, western Oregon

    USGS Publications Warehouse

    Buccola, Norman L.; Turner, Daniel F.; Rounds, Stewart A.

    2016-09-14

    Significant FindingsStreamflow and water temperature in the Middle Fork Willamette River (MFWR), western Oregon, have been regulated and altered since the construction of Lookout Point, Dexter, and Hills Creek Dams in 1954 and 1961, respectively. Each year, summer releases from the dams typically are cooler than pre-dam conditions, with the reverse (warmer than pre-dam conditions) occurring in autumn. This pattern has been detrimental to habitat of endangered Upper Willamette River (UWR) Chinook salmon (Oncorhynchus tshawytscha) and UWR winter steelhead (O. mykiss) throughout multiple life stages. In this study, scenarios testing different dam-operation strategies and hypothetical dam-outlet structures were simulated using CE-QUAL-W2 hydrodynamic/temperature models of the MFWR system from Hills Creek Lake (HCR) to Lookout Point (LOP) and Dexter (DEX) Lakes to explore and understand the efficacy of potential flow and temperature mitigation options.Model scenarios were run in constructed wet, normal, and dry hydrologic calendar years, and designed to minimize the effects of Hills Creek and Lookout Point Dams on river temperature by prioritizing warmer lake surface releases in May–August and cooler, deep releases in September–December. Operational scenarios consisted of a range of modified release rate rules, relaxation of power-generation constraints, variations in the timing of refill and drawdown, and maintenance of different summer maximum lake levels at HCR and LOP. Structural scenarios included various combinations of hypothetical floating outlets near the lake surface and hypothetical new outlets at depth. Scenario results were compared to scenarios using existing operational rules that give temperature management some priority (Base), scenarios using pre-2012 operational rules that prioritized power generation over temperature management (NoBlend), and estimated temperatures from a without-dams condition (WoDams).Results of the tested model scenarios led to the following conclusions:The existing outlets at Lookout Point Dam, because of the range of depths, allow for greater temperature control than the two existing outlets at Hills Creek Dam that are relatively deep.Temperature control at HCR through operational scenarios generally was minimal near Hills Creek Dam, but improved downstream toward the head of LOP when decreased release rates held HCR at a low lake elevation year-round.Inflows from unregulated streams between HCR and LOP helped to dilute the effects of HCR and achieve more natural stream temperatures before the MFWR entered LOP.The relative benefit of any particular scenario depended on the location in the MFWR system used to assess the potential change, with most scenarios involving changes to Hills Creek Dam being less effective with increasing downstream distance, such as downstream of DEX.To achieve as much temperature control as the most successful structural scenarios, which were able to resemble without-dam conditions for part of the year, most operational scenarios had to be free of any power-generation requirements at Lookout Point Dam.Downstream of DEX, scenarios incorporating a hypothetical floating outlet at either HCR or LOP resulted in similar temperatures, with both scenarios causing a delay in the estimated spring Chinook egg emergence by about 9–10 days compared to base-case temperature-management scenarios.

  6. Variable leak gas source

    DOEpatents

    Henderson, Timothy M.; Wuttke, Gilbert H.

    1977-01-01

    A variable leak gas source and a method for obtaining the same which includes filling a quantity of hollow glass micro-spheres with a gas, storing said quantity in a confined chamber having a controllable outlet, heating said chamber above room temperature, and controlling the temperature of said chamber to control the quantity of gas passing out of said controllable outlet. Individual gas filled spheres may be utilized for calibration purposes by breaking a sphere having a known quantity of a known gas to calibrate a gas detection apparatus.

  7. Measuring the food environment in three rural towns in New South Wales, Australia.

    PubMed

    Innes-Hughes, Christine; Boylan, Sinead; King, Lesley A; Lobb, Elizabeth

    2012-08-01

    Food availability affects eating habits, and in the Australian context, refers to the numbers and locations of food retail and food service outlets and the types and range of foods in those outlets. The aim of this study was to assess the community and consumer food environment in three small rural towns in New South Wales, Australia. Geographical analyses were used to measure the diversity, variety and locations of food outlets (community food environment); and checklists were used to assess the availability of selected indicator foods within food outlets (consumer food environment). Supermarkets provided access to the full range of healthy indicator foods, with convenience stores selling a more limited set of healthy food items. There were high numbers of take-away food outlets in each town that had no, or a limited number of, healthy food items. Energy-dense, nutrient-poor foods such as soft drinks and potato crisps were readily available across all food retail outlets in all towns. This study illustrates a valid, reliable and practical way of systematically describing food availability at a local level. The findings emphasise the ubiquity of energy-dense, nutrient-poor foods, and suggest that interventions to promote the availability of healthier food items in take-away food outlets are required. Further research is required to assess other factors which may affect residents' food access, such as cost and transport.

  8. Preliminary Results of Altitude-Wind-Tunnel Investigation of X24C-4B Turbojet Engine. I - Pressure and Temperature Distributions

    NASA Technical Reports Server (NTRS)

    Prince, William R.; Hawkins, W. Kent

    1947-01-01

    Pressures and temperatures throughout the X24C-4B turbojet engine are presented in both tabular and graphical forms to show the effect of altitude, flight Mach number, and engine speed on the internal operation of the engine. These data were obtained in the NACA Cleveland altitude wind tunnel at simulated altitudes from 5000 to 45,000 feet, simulated flight Mach numbers from 0.25 to 1.08, and engine speeds from 4000 to 12,500 rpm. Location and detail drawings of the instrumentation installed at seven survey stations in the engine are shown. Application of generalization factors to pressures and temperatures at each measuring station for the range of altitudes investigated showed that the data did not generalize above an altitude of 25,000 feet. Total-pressure distribution at the compressor outlet varied only with change in engine speed. At altitudes above 35,000 feet and engine speeds above 11,000 rpm, the peak temperature at the turbine-outlet annulus moved inward toward the root of the blade, which is undesirable from blade-stress considerations. The temperature levels at the turbine outlet and the exhaust-nozzle outlet were lowered as the Mach number was increased. The static-pressure measurements obtained at each stator stage of the compressor showed a pressure drop through the inlet guide vanes and the first-stage rotor at high engine speeds. The average values measured by the manufacturer's instrumentation werein close agreement with the average values obtained with NACA instrumentation.

  9. The influence of cavitation on the flow characteristics of liquid nitrogen through spray nozzles: A CFD study

    NASA Astrophysics Data System (ADS)

    Xue, Rong; Ruan, Yixiao; Liu, Xiufang; Cao, Feng; Hou, Yu

    2017-09-01

    Spray cooling with cryogen could achieve lower temperature level than refrigerant spray. The internal flow conditions within spray nozzles have crucial impacts on the mass flow rate, particle size, spray angle and spray penetration, thereby influencing the cooling performance. In this paper, CFD simulations based on mixture model are performed to study the cavitating flow of liquid nitrogen in spray nozzles. The cavitation model is verified using the experimental results of liquid nitrogen flow over hydrofoil. The numerical models of spray nozzle are validated against the experimental data of the mass flow rate of liquid nitrogen flow through different types of nozzles including the pressure swirl nozzle and the simple convergent nozzle. The numerical studies are performed under a wide range of pressure difference and inflow temperature, and the vapor volume fraction distribution, outlet vapor quality, mass flow rate and discharge coefficient are obtained. The results show that the outlet diameter, the pressure difference, and the inflow temperature significantly influence the mass flow rate of spray nozzles. The increase of the inflow temperature leads to higher saturation pressure, higher cavitation intensity, and more vapor at nozzle outlet, which can significantly reduce mass flow rate. While the discharge coefficient is mainly determined by the inflow temperature and has little dependence on the pressure difference and outlet diameter. Based on the numerical results, correlations of discharge coefficient are proposed for pressure swirl nozzle and simple convergent nozzles, respectively, and the deviation is less than 20% for 93% of data.

  10. Spray drying of fruit and vegetable juices--a review.

    PubMed

    Verma, Anjali; Singh, Satya Vir

    2015-01-01

    The main cause of spray drying is to increase the shelf life and easy handling of juices. In the present paper, the studies carried out so far on spray drying of various fruits and vegetables are reported. The major fruit juices dried are mango, banana, orange, guava, bayberry, watermelon, pineapple, etc. However, study on vegetable juices is limited. In spray drying, the major optimized parameters are inlet air temperature, relative humidity of air, outlet air temperature, and atomizer speed that are given for a particular study. The juices in spray drying require addition of drying agents that include matlodextrin, liquid glucose, etc. The drying agents are added to increase the glass transition temperature. Different approaches for spray dryer design have also been discussed in the present work.

  11. 40 CFR 63.6625 - What are my monitoring, installation, collection, operation, and maintenance requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CEMS must be installed at both the inlet and outlet of the control device. If you are meeting a requirement to limit the concentration of CO, the CEMS must be installed at the outlet of the control device... appropriate for the applicable limitation) at 15 percent oxygen or the equivalent CO2 concentration. (b) If...

  12. Neighborhood alcohol outlet density and genetic influences on alcohol use: evidence for gene-environment interaction.

    PubMed

    Slutske, Wendy S; Deutsch, Arielle R; Piasecki, Thomas M

    2018-05-07

    Genetic influences on alcohol involvement are likely to vary as a function of the 'alcohol environment,' given that exposure to alcohol is a necessary precondition for genetic risk to be expressed. However, few gene-environment interaction studies of alcohol involvement have focused on characteristics of the community-level alcohol environment. The goal of this study was to examine whether living in a community with more alcohol outlets would facilitate the expression of the genetic propensity to drink in a genetically-informed national survey of United States young adults. The participants were 2434 18-26-year-old twin, full-, and half-sibling pairs from Wave III of the National Longitudinal Study of Adolescent to Adult Health. Participants completed in-home interviews in which alcohol use was assessed. Alcohol outlet densities were extracted from state-level liquor license databases aggregated at the census tract level to derive the density of outlets. There was evidence that the estimates of genetic and environmental influences on alcohol use varied as a function of the density of alcohol outlets in the community. For example, the heritability of the frequency of alcohol use for those residing in a neighborhood with ten or more outlets was 74% (95% confidence limits = 55-94%), compared with 16% (95% confidence limits = 0-34%) for those in a neighborhood with zero outlets. This moderating effect of alcohol outlet density was not explained by the state of residence, population density, or neighborhood sociodemographic characteristics. The results suggest that living in a neighborhood with many alcohol outlets may be especially high-risk for those individuals who are genetically predisposed to frequently drink.

  13. Baseline Concept Description of a Small Modular High Temperature Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hans Gougar

    2014-05-01

    The objective of this report is to provide a description of generic small modular high temperature reactors (herein denoted as an smHTR), summarize their distinguishing attributes, and lay out the research and development (R&D) required for commercialization. The generic concepts rely heavily on the modular high temperature gas-cooled reactor designs developed in the 1980s which were never built but for which pre-licensing or certification activities were conducted. The concept matured more recently under the Next Generation Nuclear Plant (NGNP) project, specifically in the areas of fuel and material qualification, methods development, and licensing. As all vendor-specific designs proposed under NGNPmore » were all both ‘small’ or medium-sized and ‘modular’ by International Atomic Energy Agency (IAEA) and Department of Energy (DOE) standards, the technical attributes, challenges, and R&D needs identified, addressed, and documented under NGNP are valid and appropriate in the context of Small Modular Reactor (SMR) applications. Although the term High Temperature Reactor (HTR) is commonly used to denote graphite-moderated, thermal spectrum reactors with coolant temperatures in excess of 650oC at the core outlet, in this report the historical term High Temperature Gas-Cooled Reactor (HTGR) will be used to distinguish the gas-cooled technology described herein from its liquid salt-cooled cousin. Moreover, in this report it is to be understood that the outlet temperature of the helium in an HTGR has an upper limit of 950 degrees C which corresponds to the temperature to which certain alloys are currently being qualified under DOE’s ARC program. Although similar to the HTGR in just about every respect, the Very High Temperature Reactor (VHTR) may have an outlet temperature in excess of 950 degrees C and is therefore farther from commercialization because of the challenges posed to materials exposed to these temperatures. The VHTR is the focus of R&D under the Generation IV program and its specific R&D needs will be included in this report when appropriate for comparison. The distinguishing features of the HTGR are the refractory (TRISO) coated particle fuel, the low-power density, graphite-moderated core, and the high outlet temperature of the inert helium coolant. The low power density and fuel form effectively eliminate the possibility of core melt, even upon a complete loss of coolant pressure and flow. The graphite, which constitutes the bulk of the core volume and mass, provides a large thermal buffer that absorbs fission heat such that thermal transients occur over a timespan of hours or even days. As chemically-inert helium is already a gas, there is no coolant temperature or void feedback on the neutronics and no phase change or corrosion product that could degrade heat transfer. Furthermore, the particle coatings and interstitial graphite retain fission products such that the source terms at the plant boundary remain well below actionable levels under all anticipated nominal and off-normal operating conditions. These attributes enable the reactor to supply process heat to a collocated industrial plant with negligible risk of contamination and minimal dynamic coupling of the facilities (Figure 1). The exceptional retentive properties of coated particle fuel in a graphite matrix were first demonstrated in the DRAGON reactor, a European research facility that began operation in 1964.« less

  14. Baseline Concept Description of a Small Modular High Temperature Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gougar, Hans D.

    2014-10-01

    The objective of this report is to provide a description of generic small modular high temperature reactors (herein denoted as an smHTR), summarize their distinguishing attributes, and lay out the research and development (R&D) required for commercialization. The generic concepts rely heavily on the modular high temperature gas-cooled reactor designs developed in the 1980s which were never built but for which pre-licensing or certification activities were conducted. The concept matured more recently under the Next Generation Nuclear Plant (NGNP) project, specifically in the areas of fuel and material qualification, methods development, and licensing. As all vendor-specific designs proposed under NGNPmore » were all both ‘small’ or medium-sized and ‘modular’ by International Atomic Energy Agency (IAEA) and Department of Energy (DOE) standards, the technical attributes, challenges, and R&D needs identified, addressed, and documented under NGNP are valid and appropriate in the context of Small Modular Reactor (SMR) applications. Although the term High Temperature Reactor (HTR) is commonly used to denote graphite-moderated, thermal spectrum reactors with coolant temperatures in excess of 650oC at the core outlet, in this report the historical term High Temperature Gas-Cooled Reactor (HTGR) will be used to distinguish the gas-cooled technology described herein from its liquid salt-cooled cousin. Moreover, in this report it is to be understood that the outlet temperature of the helium in an HTGR has an upper limit of 950 degrees C which corresponds to the temperature to which certain alloys are currently being qualified under DOE’s ARC program. Although similar to the HTGR in just about every respect, the Very High Temperature Reactor (VHTR) may have an outlet temperature in excess of 950 degrees C and is therefore farther from commercialization because of the challenges posed to materials exposed to these temperatures. The VHTR is the focus of R&D under the Generation IV program and its specific R&D needs will be included in this report when appropriate for comparison. The distinguishing features of the HTGR are the refractory (TRISO) coated particle fuel, the low-power density, graphite-moderated core, and the high outlet temperature of the inert helium coolant. The low power density and fuel form effectively eliminate the possibility of core melt, even upon a complete loss of coolant pressure and flow. The graphite, which constitutes the bulk of the core volume and mass, provides a large thermal buffer that absorbs fission heat such that thermal transients occur over a timespan of hours or even days. As chemically-inert helium is already a gas, there is no coolant temperature or void feedback on the neutronics and no phase change or corrosion product that could degrade heat transfer. Furthermore, the particle coatings and interstitial graphite retain fission products such that the source terms at the plant boundary remain well below actionable levels under all anticipated nominal and off-normal operating conditions. These attributes enable the reactor to supply process heat to a collocated industrial plant with negligible risk of contamination and minimal dynamic coupling of the facilities (Figure 1). The exceptional retentive properties of coated particle fuel in a graphite matrix were first demonstrated in the DRAGON reactor, a European research facility that began operation in 1964.« less

  15. Analysis of Temperature and Humidity Field in a New Bulk Tobacco Curing Barn Based on CFD.

    PubMed

    Bai, Zhipeng; Guo, Duoduo; Li, Shoucang; Hu, Yaohua

    2017-01-31

    A new structure bulk tobacco curing barn was presented. To study the temperature and humidity field in the new structure tobacco curing barn, a 3D transient computational fluid dynamics (CFD) model was developed using porous medium, species transport, κ-ε turbulence and discrete phase models. The CFD results demonstrated that (1) the temperature and relative humidity predictions were validated by the experimental results, and comparison of simulation results with experimental data showed a fairly close agreement; (2) the temperature of the bottom and inlet area was higher than the top and outlet area, and water vapor concentrated on the top and outlet area in the barn; (3) tobacco loading density and thickness of tobacco leaves had an explicit effect on the temperature distributions in the barn.

  16. Control of Advanced Reactor-Coupled Heat Exchanger System: Incorporation of Reactor Dynamics in System Response to Load Disturbances

    DOE PAGES

    Skavdahl, Isaac; Utgikar, Vivek; Christensen, Richard; ...

    2016-05-24

    We present an alternative control schemes for an Advanced High Temperature Reactor system consisting of a reactor, an intermediate heat exchanger, and a secondary heat exchanger (SHX) in this paper. One scheme is designed to control the cold outlet temperature of the SHX (T co) and the hot outlet temperature of the intermediate heat exchanger (T ho2) by manipulating the hot-side flow rates of the heat exchangers (F h/F h2) responding to the flow rate and temperature disturbances. The flow rate disturbances typically require a larger manipulation of the flow rates than temperature disturbances. An alternate strategy examines the controlmore » of the cold outlet temperature of the SHX (T co) only, since this temperature provides the driving force for energy production in the power conversion unit or the process application. The control can be achieved by three options: (1) flow rate manipulation; (2) reactor power manipulation; or (3) a combination of the two. The first option has a quicker response but requires a large flow rate change. The second option is the slowest but does not involve any change in the flow rates of streams. The final option appears preferable as it has an intermediate response time and requires only a minimal flow rate change.« less

  17. Characterization and statistical modeling of bacterial (Escherichia coli) outflows from watersheds that discharge into Southern Lake Michigan

    USGS Publications Warehouse

    Olyphant, G.A.; Thomas, Joan; Whitman, R.L.; Harper, D.

    2003-01-01

    Two watersheds in northwestern Indiana were selected for detailed monitoring of bacterially contaminated discharges (Escherichia coli) into Lake Michigan. A large watershed that drains an urbanized area with treatment plants that release raw sewage during storms discharges into Lake Michigan at the outlet of Burns Ditch. A small watershed drains part of the Great Marsh, a wetland complex that has been disrupted by ditching and limited residential development, at the outlet of Derby Ditch. Monitoring at the outlet of Burns Ditch in 1999 and 2000 indicated that E. coli concentrations vary over two orders of magnitude during storms. During one storm, sewage overflows caused concentrations to increase to more than 10,000 cfu/100 mL for several hours. Monitoring at Derby Ditch from 1997 to 2000 also indicated that E. coli concentrations increase during storms with the highest concentrations generally occurring during rising streamflow. Multiple regression analysis indicated that 60% of the variability in measured outflows of E. coli from Derby Ditch (n = 88) could be accounted for by a model that utilizes continuously measured rainfall, stream discharge, soil temperature and depth to water table in the Great Marsh. A similar analysis indicated that 90% of the variability in measured E. coli concentrations at the outlet of Burns Ditch (n = 43) during storms could be accounted for by a combination of continuously measured water-quality variables including nitrate and ammonium. These models, which utilize data that can be collected on a real-time basis, could form part of an Early Warning System for predicting beach closures.

  18. Pressure, temperature and density drops along supercritical fluid chromatography columns in different thermal environments. III. Mixtures of carbon dioxide and methanol as the mobile phase.

    PubMed

    Poe, Donald P; Veit, Devon; Ranger, Megan; Kaczmarski, Krzysztof; Tarafder, Abhijit; Guiochon, Georges

    2014-01-03

    The pressure, temperature and density drops along SFC columns eluted with a CO2/methanol mobile phase were measured and compared with theoretical values. For columns packed with 3- and 5-μm particles the pressure and temperature drops were measured using a mobile phase of 95% CO2 and 5% methanol at a flow rate of 5mL/min, at temperatures from 20 to 100°C, and outlet pressures from 80 to 300bar. The density drop was calculated based on the temperature and pressure at the column inlet and outlet. The columns were suspended in a circulating air bath, either bare or covered with foam insulation. The experimental measurements were compared to theoretical results obtained by numerical simulation. For the convective air condition at outlet pressures above 100bar the average difference between the experimental and calculated temperature drops and pressure drops were 0.1°C and 0.7% for the bare 3-μm column, respectively, and were 0.6°C and 4.1% for the insulated column. The observed temperature drops for the insulated columns are consistent with those predicted by the Joule-Thomson coefficients for isenthalpic expansion. The dependence of the temperature and the pressure drops on the Joule-Thomson coefficient and kinematic viscosity are described for carbon dioxide mobile phases containing up to 20% methanol. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Spray Drying of Spinach Juice: Characterization, Chemical Composition, and Storage.

    PubMed

    Çalışkan Koç, Gülşah; Nur Dirim, Safiye

    2017-12-01

    The 1st aim of this study is to determine the influence of inlet and outlet air temperatures on the physical and chemical properties of obtained powders from spinach juice (SJ) with 3.2 ± 0.2 °Brix (°Bx). Second, the effect of 3 different drying agents (maltodextrin, whey powder, and gum Arabic) on the same properties was investigated for the selected inlet/outlet temperatures (160/100 °C) which gives the minimum moisture content and water activity values. For this purpose, the total soluble solid content of SJ was adjusted to 5.0 ± 0.2 °Bx with different drying agents. Finally, the effects of different storage conditions (4, 20, and 30 °C) on the physical and chemical properties of spinach powders (SPs) produced at selected conditions were examined. A pilot scale spray dryer was used at 3 different inlet/outlet air temperatures (160 to 200 °C/80 to 100 °C) where the outlet air temperature was controlled by regulating the feed flow rate. Results showed that the moisture content, water activity, browning index, total chlorophyll, and total phenolic contents of the SP significantly decreased and pH and total color change of the SP significantly increased by the addition of different drying agents (P < 0.05). In addition, the changes in the above-mentioned properties were determined during the storage period, at 3 different temperatures. It was also observed that the vitamin C, β-carotene, chlorophyll, and phenolic compounds retention showed first-order degradation kinetic with activation energy of 32.6840, 10.2736, 27.7031, and 28.2634 kJ/K.mol, respectively. © 2017 Institute of Food Technologists®.

  20. Rapid and selective brain cooling method using vortex tube: A feasibility study.

    PubMed

    Bakhsheshi, Mohammad Fazel; Keenliside, Lynn; Lee, Ting-Yim

    2016-05-01

    Vortex tubes are simple mechanical devices to produce cold air from a stream of compressed air without any moving parts. The primary focus of the current study is to investigate the feasibility and efficiency of nasopharyngeal brain cooling method using a vortex tube. Experiments were conducted on 5 juvenile pigs. Nasopharygeal brain cooling was achieved by directing cooled air via a catheter in each nostril into the nasal cavities. A vortex tube was used to generate cold air using various sources of compressed air: (I) hospital medical air outlet (n = 1); (II) medical air cylinders (n = 3); and (III) scuba (diving) cylinders (n = 1). By using compressed air from a hospital medical air outlet at fixed inlet pressure of 50 PSI, maximum brain-rectal temperature gradient of -2°C was reached about 45-60 minutes by setting the flow rate of 25 L/min and temperature of -7°C at the cold air outlet. Similarly, by using medical air cylinders at fill-pressure of 2265 PSI and down regulate the inlet pressure to the vortex tube to 50 PSI, brain temperature could be reduced more rapidly by blowing -22°C ± 2°C air at a flow rate of 50 L/min; brain-body temperature gradient of -8°C was obtained about 30 minutes. Furthermore, we examined scuba cylinders as a portable source of compressed gas supply to the vortex tube. Likewise, by setting up the vortex tube to have an inlet pressure of 25 PSI and 50 L/min and -3°C at the cold air outlet, brain temperature decreased 4.5°C within 10-20 min. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Underage purchasing of alcohol from packaged liquor outlets: an Australian study.

    PubMed

    Rowland, Bosco C; Hall, Jessica K; Kremer, Peter J; Miller, Peter G; Toumbourou, John W

    2017-10-01

    Access to the supply of alcohol is an important factor influencing adolescent alcohol consumption. Although alcohol sales outlets are prohibited from selling alcohol to underage youth, there has been limited research investigating compliance. The present study sought to estimate the extent to which adolescents that appeared underage were successfully able to purchase alcohol from packaged liquor outlets in Australia; and to identify store and sales characteristics associated with illegal purchasing. In 2012, purchase surveys were conducted (n= 310) at packaged liquor outlets in 28 urban and rural communities across three states of Australia: Western Australia, Queensland and Victoria. Confederates successfully purchased alcohol at 60% (95% CI: 55-66) of outlets. The density of general alcohol outlets in the surrounding area and the type of liquor outlet were predictors of successful alcohol purchases; however, this was moderated by the state in which the purchase was made. Regional geographical location was also found to predict underage alcohol purchase. The majority of alcohol sales outlets in Australia breach regulations prohibiting sales to underage youth. Consistent enforcement of policies across the states of Australia, and reducing the number of alcohol outlets, will help prevent alcohol outlets illegally selling alcohol to underage adolescents. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Wastewater heat recovery method and apparatus

    DOEpatents

    Kronberg, J.W.

    1991-01-01

    This invention is comprised of a heat recovery system with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature.

  3. Wastewater heat recovery apparatus

    DOEpatents

    Kronberg, James W.

    1992-01-01

    A heat recovery system with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oktamuliani, Sri, E-mail: srioktamuliani@ymail.com; Su’ud, Zaki, E-mail: szaki@fi.itb.ac.id

    A preliminary study designs SPINNOR (Small Power Reactor, Indonesia, No On-Site Refueling) liquid metal Pb-Bi cooled fast reactors, fuel (U, Pu)N, 150 MWth have been performed. Neutronic calculation uses SRAC which is designed cylindrical core 2D (R-Z) 90 × 135 cm, on the core fuel composed of heterogeneous with percentage difference of PuN 10, 12, 13% and the result of calculation is effective neutron multiplication 1.0488. Power density distribution of the output SRAC is generated for thermal hydraulic calculation using Delphi based on Pascal language that have been developed. The research designed a reactor that is capable of natural circulation atmore » inlet temperature 300 °C with variation of total mass flow rate. Total mass flow rate affect pressure drop and temperature outlet of the reactor core. The greater the total mass flow rate, the smaller the outlet temperature, but increase the pressure drop so that the chimney needed more higher to achieve natural circulation or condition of the system does not require a pump. Optimization of the total mass flow rate produces optimal reactor design on the total mass flow rate of 5000 kg/s with outlet temperature 524,843 °C but require a chimney of 6,69 meters.« less

  5. Wastewater heat recovery apparatus

    DOEpatents

    Kronberg, J.W.

    1992-09-01

    A heat recovery system is described with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature. 6 figs.

  6. 40 CFR Table 3 to Subpart Kkkk of... - Emission Limits for Affected Sources Using the Control Efficiency/Outlet Concentration Compliance...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reconstructed affected source a. reduce emissions of total HAP, measured as THC (as carbon), a by 97 percent; orb. limit emissions of total HAP, measured as THC (as carbon), a to 20 ppmvd at the control device outlet and use a PTE. 2. in an existing affected source a. reduce emissions of total HAP, measured as THC...

  7. 40 CFR Table 3 to Subpart Kkkk of... - Emission Limits for Affected Sources Using the Control Efficiency/Outlet Concentration Compliance...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reconstructed affected source a. reduce emissions of total HAP, measured as THC (as carbon), a by 97 percent; orb. limit emissions of total HAP, measured as THC (as carbon), a to 20 ppmvd at the control device outlet and use a PTE. 2. in an existing affected source a. reduce emissions of total HAP, measured as THC...

  8. 40 CFR Table 3 to Subpart Kkkk of... - Emission Limits for Affected Sources Using the Control Efficiency/Outlet Concentration Compliance...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reconstructed affected source a. reduce emissions of total HAP, measured as THC (as carbon), a by 97 percent; orb. limit emissions of total HAP, measured as THC (as carbon), a to 20 ppmvd at the control device outlet and use a PTE. 2. in an existing affected source a. reduce emissions of total HAP, measured as THC...

  9. 40 CFR Table 3 to Subpart Kkkk of... - Emission Limits for Affected Sources Using the Control Efficiency/Outlet Concentration Compliance...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... affected source a. reduce emissions of total HAP, measured as THC (as carbon), a by 97 percent; orb. limit emissions of total HAP, measured as THC (as carbon), a to 20 ppmvd at the control device outlet and use a PTE. 2. in an existing affected source a. reduce emissions of total HAP, measured as THC (as carbon...

  10. 40 CFR Table 3 to Subpart Kkkk of... - Emission Limits for Affected Sources Using the Control Efficiency/Outlet Concentration Compliance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... affected source a. reduce emissions of total HAP, measured as THC (as carbon), a by 97 percent; orb. limit emissions of total HAP, measured as THC (as carbon), a to 20 ppmvd at the control device outlet and use a PTE. 2. in an existing affected source a. reduce emissions of total HAP, measured as THC (as carbon...

  11. Complex Greenland outlet glacier flow captured

    PubMed Central

    Aschwanden, Andy; Fahnestock, Mark A.; Truffer, Martin

    2016-01-01

    The Greenland Ice Sheet is losing mass at an accelerating rate due to increased surface melt and flow acceleration in outlet glaciers. Quantifying future dynamic contributions to sea level requires accurate portrayal of outlet glaciers in ice sheet simulations, but to date poor knowledge of subglacial topography and limited model resolution have prevented reproduction of complex spatial patterns of outlet flow. Here we combine a high-resolution ice-sheet model coupled to uniformly applied models of subglacial hydrology and basal sliding, and a new subglacial topography data set to simulate the flow of the Greenland Ice Sheet. Flow patterns of many outlet glaciers are well captured, illustrating fundamental commonalities in outlet glacier flow and highlighting the importance of efforts to map subglacial topography. Success in reproducing present day flow patterns shows the potential for prognostic modelling of ice sheets without the need for spatially varying parameters with uncertain time evolution. PMID:26830316

  12. Thermodynamics Analysis of Binary Plant Generating Power from Low-Temperature Geothermal Resource

    NASA Astrophysics Data System (ADS)

    Maksuwan, A.

    2018-05-01

    The purpose in this research was to predict tendency of increase Carnot efficiency of the binary plant generating power from low-temperature geothermal resource. Low-temperature geothermal resources or less, are usually exploited by means of binary-type energy conversion systems. The maximum efficiency is analyzed for electricity production of the binary plant generating power from low-temperature geothermal resource becomes important. By using model of the heat exchanger equivalent to a power plant together with the calculation of the combined heat and power (CHP) generation. The CHP was solved in detail with appropriate boundary originating an idea from the effect of temperature of source fluid inlet-outlet and cooling fluid supply. The Carnot efficiency from the CHP calculation was compared between condition of increase temperature of source fluid inlet-outlet and decrease temperature of cooling fluid supply. Result in this research show that the Carnot efficiency for binary plant generating power from low-temperature geothermal resource has tendency increase by decrease temperature of cooling fluid supply.

  13. Systems and methods for thermal imaging technique for measuring mixing of fluids

    DOEpatents

    Booten, Charles; Tomerlin, Jeff; Winkler, Jon

    2016-06-14

    Systems and methods for thermal imaging for measuring mixing of fluids are provided. In one embodiment, a method for measuring mixing of gaseous fluids using thermal imaging comprises: positioning a thermal test medium parallel to a direction gaseous fluid flow from an outlet vent of a momentum source, wherein when the source is operating, the fluid flows across a surface of the medium; obtaining an ambient temperature value from a baseline thermal image of the surface; obtaining at least one operational thermal image of the surface when the fluid is flowing from the outlet vent across the surface, wherein the fluid has a temperature different than the ambient temperature; and calculating at least one temperature-difference fraction associated with at least a first position on the surface based on a difference between temperature measurements obtained from the at least one operational thermal image and the ambient temperature value.

  14. Pressure vessel and method therefor

    DOEpatents

    Saunders, Timothy

    2017-09-05

    A pressure vessel includes a pump having a passage that extends between an inlet and an outlet. A duct at the pump outlet includes at least one dimension that is adjustable to facilitate forming a dynamic seal that limits backflow of gas through the passage.

  15. Long-term dynamics of a tidewater outlet glacier in West Greenland and its relation to external forcing

    NASA Astrophysics Data System (ADS)

    Vieli, Andreas; Luethi, Martin; Moreau, Luc; Reisser, Moritz; Ian, Joughin

    2015-04-01

    Dynamic changes of ocean-terminating outlet glaciers such as terminus retreat and flow acceleration are responsible for about half of the current mass loss of the Greenland ice sheet. Although these changes seem related to the general warming in recent decades, the detailed link between external forcing from the atmosphere and/or ocean and glacier response is not well understood. Further, existing observations of tidewater outlet glacier change also show strong temporal fluctuations and are mostly limited to the last two decades of satellite observations. It is therefore difficult to derive and interpret long-term trends in outlet glacier change which is relevant in the context of century scale predictions. Here we present and analyse a detailed long-term record of flow and geometry evolution of Eqi Sermia, a ocean terminating outlet glacier in West Greenland. This record starts in 1912 and has, due to its proximity to the main access route for early expeditions to the ice sheet, a decadal and smaller resolution. This historic record is supplemented by data from satellites and ground based radar interferometry for deriving front positions and flow velocities in the two recent decades. The front and flow speed of Eqi Sermia was more or less stable between 1912 with aslow retreat phase between 1920 to the 1960, followed by a slight readvance in the 1980s. In 2007 the terminus started to retreat very rapidly, retreated 3 km since and in a step wise fashion and almost quadrupled its flow speed at the terminus. A comparison with surface mass balance and temperature records suggests a close relation of the long-term evolution of Egi Sermia to atmospheric forcing rather than oceanic, perhaps reflecting the relatively shallow fjord depths. In contrast, the recent rapid retreat and acceleration may be due to a changing regime in the calving process and geometric effects.

  16. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    PubMed Central

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  17. Acute alcohol consumption, alcohol outlets, and gun suicide.

    PubMed

    Branas, Charles C; Richmond, Therese S; Ten Have, Thomas R; Wiebe, Douglas J

    2011-01-01

    A case-control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed.

  18. Sediment concentration and turbidity changes during culvert removals.

    PubMed

    Foltz, Randy B; Yanosek, Kristina A; Brown, Timothy M

    2008-05-01

    The concentrations of sediment and turbidity in stream water were monitored during culvert removals to determine the short term effects of road obliteration. Sediment concentration was measured at 11 stream crossings among two locations in Idaho and one in Washington. Sediment concentration immediately below the culvert outlet exceeded levels above the culvert outlet by at least three orders of magnitude at all stream crossings. Sediment yields ranged from 170 to less than 1kg in the 24-h period following culvert removal. Turbidity exceeded the regulatory limits during culvert removal at all locations monitored in this study and remained above the limits beyond the monitoring periods of 24h at four of the locations. Sediment concentrations 100m downstream of the culvert outlet were reduced by an order of magnitude, but did not change the turbidity values sufficiently to meet regulatory limits. Sediment concentrations an average of 810m downstream of the culvert outlet were similar to sediment concentrations above the culvert for the entire excavation period and turbidity regulations were met. Mitigation consisting of two straw bales placed in the stream caused a significant reduction in sediment yield from an average of 67kg to an average of 1.6kg.

  19. An investigation on polycyclic aromatic hydrocarbon emissions from pulverized coal combustion systems

    PubMed

    Pisupati; Wasco; Scaroni

    2000-05-29

    Results from a series of tests conducted to study the emission of polynuclear or polycyclic aromatic hydrocarbons (PAHs) from bench-scale and small industrial, water-tube boiler are discussed. A Middle Kittanning, and Upper Freeport seam coals were used in the study. Samples were extracted from the reactor outlet and from the inlet and outlet sides of the research boiler's (RB) baghouse using EPA promulgated methods.Only acenaphthene and fluoranthene were detected in down-fired combustor (DFC) samples. In addition to these two, naphthalene was detected in the RB samples. Emission factors ranged from 80 to 320 &mgr;g/kg of fuel fired. Although there were minor trends in the emissions' data, given the reproducibility limits for PAH compounds, no significant differences were found in the emissions with respect to the fuel type or form (pulverized coal (PC) vs. coal-water slurry fuel (CWSF), and raw vs. cleaned coal) and firing conditions (high and low excess air). The PAH emissions showed a decrease with increase in the firing rate.A bench-scale drop-tube reactor (DTR) was used to study the effects of temperature and residence time on PAH formation. The results revealed near constant PAH concentrations in the solid-phase samples, while the PAH concentrations in the vapor-phase samples increased as a function of temperature. At a temperature of around 1300 degrees C, the rate of PAH formation was exceeded by the rate of PAH oxidation, and PAH concentrations in the vapor phase began to decrease.

  20. Defining treatment conditions for pulsed electric field pasteurization of apple juice.

    PubMed

    Saldaña, G; Puértolas, E; Monfort, S; Raso, J; Alvarez, I

    2011-11-15

    The influence of temperature and the presence of N(α)-lauroyl ethylester (ethyl lauroyl arginate, LAE) on the inactivation caused by continuous pulsed electric field treatments (PEF) in Escherichia coli O157:H7 suspended in apple juice have been investigated to define treatment conditions applicable at industrial scale that promote an equivalent safety level when compared with thermal processing. In the range of experimental conditions investigated (outlet temperature: 20-40 °C, electric field strength: 20-30 kV, treatment time: 5-125 μs) at outlet temperatures equal or lower than 55±1 °C, the inactivation of E. coli O157:H7 treated in apple juice ranged from 0.4 to 3.6 Log₁₀ cycles reduction and treated in apple juice supplemented with LAE (50 ppm) ranged from 0.9 to 6.7 Log₁₀ cycles reduction. An empirical mathematical model was developed to estimate the treatment time and total specific energy input to obtain 5 Log₁₀ cycles reduction in the population of E. coli O157:H7 suspended in apple juice supplemented with 50 ppm of LAE at different electric field strengths and inlet temperatures. Treatment conditions established for E. coli O157:H7 were validated with other PEF resistant Gram-positive (Listeria monocytogenes, and Staphylococcus aureus) and Gram-negative (Salmonella enterica serovar Typhimurium) strains. When the treatment was applied to the apple juice, a treatment of 25 kV/cm for 63 μs corresponding with an outlet temperature of 65 °C and input energy of 125 kJ/kg was required to achieve more than 5 Log₁₀ cycles in the four strains investigated. The addition of LAE reduced the treatment time required to obtain an equivalent inactivation (>5 Log₁₀ cycles) in the four microorganisms to 38.4 μs, the outlet temperature to 55 °C, and the input energy to 83.2 kJ/kg. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Method and apparatus for providing a precise amount of gas at a precise humidity

    DOEpatents

    Hallman, Jr., Russell L.; Truett, James C.

    2001-02-06

    A fluid transfer system includes a permeable fluid carrier, a constant temperature source of a first fluid, and a constant pressure source of a second fluid. The fluid carrier has a length, an inlet end, and an outlet end. The constant pressure source connects to the inlet end and communicates the second fluid into the fluid carrier, and the constant temperature source surrounds a least of portion of the length. A mixture of the first fluid and the second fluid exits via the outlet end A method of making a mixture of two fluids is also disclosed.

  2. Preliminary Cosmogenic Surface Exposure Ages on Laurentide Ice-sheet Retreat and Opening of the Eastern Lake Agassiz Outlets

    NASA Astrophysics Data System (ADS)

    Leydet, D.; Carlson, A. E.; Sinclair, G.; Teller, J. T.; Breckenridge, A. J.; Caffee, M. W.; Barth, A. M.

    2015-12-01

    The chronology for the eastern outlets of glacial Lake Agassiz holds important consequences for the cause of Younger Dryas cold event during the last deglaciation. Eastward routing of Lake Agassiz runoff was originally hypothesized to have triggered the Younger Dryas. However, currently the chronology of the eastern outlets is only constrained by minimum-limiting radiocarbon ages that could suggest the eastern outlets were still ice covered at the start of the Younger Dryas at ~12.9 ka BP, requiring a different forcing of this abrupt climate event. Nevertheless, the oldest radiocarbon ages are still consistent with an ice-free eastern outlet at the start of the Younger Dryas. Here we will present preliminary 10-Be cosmogenic surface exposure ages from the North Lake, Flat Rock Lake, glacial Lake Kaministiquia, and Lake Nipigon outlets located near Thunder Bay, Ontario. These ages will date the timing of the deglaciation of the Laurentide ice sheet in the eastern outlet region of glacial Lake Agassiz. This will provide an important constraint for the hypothesized freshwater forcing of the cause of Younger Dryas cold event.

  3. Malaria case detection using rapid diagnostic test at the community level in Ghana: consumer perception and practitioners' experiences.

    PubMed

    Danquah, Daniel A; Buabeng, Kwame O; Asante, Kwaku P; Mahama, Emmanuel; Bart-Plange, Constance; Owusu-Dabo, Ellis

    2016-01-22

    Ghana has scaled-up malaria control strategies over the past decade. Much as malaria morbidity and mortality seem to have declined with these efforts, there appears to be increased consumption of artemisinin-based combination therapy (ACT). This study explored the perception and experiences of community members and medicines outlet practitioners on malaria case detection using rapid diagnostic test (RDTs) to guide malaria therapy. This was a cross-sectional study using both quantitative and qualitative approaches for data. In-depth interviews with structured questionnaires were conducted among 197 practitioners randomly selected from community pharmacies and over-the-counter medicine sellers shops within two metropolis (Kumasi and Obuasi) in the Ashanti Region of Ghana. Two focus group discussions were also held in the two communities among female adult caregivers. Medicine outlet practitioners and community members often used raised body temperature of individuals as an index for malaria case detection. The raised body temperature was presumptively determined by touching the forehead with hands. Seventy percent of the practitioners' perceived malaria RDTs are used in hospitals and clinics but not in retail medicines outlets. Many of the practitioners and community members agreed to the need for using RDT for malaria case detection at medicine outlets. However, about 30% of the practitioners (n = 59) and some community members (n = 6) held the view that RDT negative results does not mean no malaria illness and would use ACT. Though malaria RDT use in medicines outlets was largely uncommon, both community members and medicine outlet practitioners welcomed its use. Public education is however needed to improve malaria case detection using RDTs at the community level, to inform appropriate use of ACT.

  4. Optimization and Comparison of Direct and Indirect Supercritical Carbon Dioxide Power Plant Cycles for Nuclear Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwin A. Harvego; Michael G. McKellar

    2011-11-01

    There have been a number of studies involving the use of gases operating in the supercritical mode for power production and process heat applications. Supercritical carbon dioxide (CO2) is particularly attractive because it is capable of achieving relatively high power conversion cycle efficiencies in the temperature range between 550 C and 750 C. Therefore, it has the potential for use with any type of high-temperature nuclear reactor concept, assuming reactor core outlet temperatures of at least 550 C. The particular power cycle investigated in this paper is a supercritical CO2 Recompression Brayton Cycle. The CO2 Recompression Brayton Cycle can bemore » used as either a direct or indirect power conversion cycle, depending on the reactor type and reactor outlet temperature. The advantage of this cycle when compared to the helium Brayton cycle is the lower required operating temperature; 550 C versus 850 C. However, the supercritical CO2 Recompression Brayton Cycle requires an operating pressure in the range of 20 MPa, which is considerably higher than the required helium Brayton cycle operating pressure of 8 MPa. This paper presents results of analyses performed using the UniSim process analyses software to evaluate the performance of both a direct and indirect supercritical CO2 Brayton Recompression cycle for different reactor outlet temperatures. The direct supercritical CO2 cycle transferred heat directly from a 600 MWt reactor to the supercritical CO2 working fluid supplied to the turbine generator at approximately 20 MPa. The indirect supercritical CO2 cycle assumed a helium-cooled Very High Temperature Reactor (VHTR), operating at a primary system pressure of approximately 7.0 MPa, delivered heat through an intermediate heat exchanger to the secondary indirect supercritical CO2 Brayton Recompression cycle, again operating at a pressure of about 20 MPa. For both the direct and indirect cycles, sensitivity calculations were performed for reactor outlet temperature between 550 C and 850 C. The UniSim models used realistic component parameters and operating conditions to model the complete reactor and power conversion systems. CO2 properties were evaluated, and the operating ranges of the cycles were adjusted to take advantage of the rapidly changing properties of CO2 near the critical point. The results of the analyses showed that, for the direct supercritical CO2 power cycle, thermal efficiencies in the range of 40 to 50% can be achieved. For the indirect supercritical CO2 power cycle, thermal efficiencies were approximately 10% lower than those obtained for the direct cycle over the same reactor outlet temperature range.« less

  5. 24 CFR 3280.609 - Water distribution systems.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... and temperature relief valve installed for this purpose shall have the temperature sensing element...) Size of branch. Start at the most remote outlet on any branch of the hot or cold water piping and...

  6. Characteristics of evacuated tubular solar thermal collector as input energy for cooling system at Universitas Indonesia

    NASA Astrophysics Data System (ADS)

    Alhamid, M. Idrus; Nasruddin, Aisyah, Nyayu; Sholahudin

    2017-03-01

    This paper discussed the use of solar thermal collector as an input energy for cooling system. The experimental investigation was undertaken to characterize solar collectors that have been integrated with an absorption chiller. About 62 modules of solar collectors connected in series and parallel are placed on the roof top of MRC building. Thermistors were used to measure the fluid temperature at inlet, inside and outlet of each collector, inside the water tank and ambient temperature. Water flow that circulated from the storage was measured by flow meter, while solar radiation was measured by a pyranometer that was mounted parallel to the collector. Experimental data for a data set was collected in March 2016, during the day time hours of 08:00 - 17:00. This data set was used to calculate solar collector efficiency. The results showed that in the maximum solar radiation, the outlet temperature that can be reached is about 78°C, the utilized energy is about 70 kW and solar collector has an efficiency of 64%. While in the minimum solar radiation, the outlet temperature that can be reached is about 53°C, the utilized energy is about 28 kW and solar collector has an efficiency of 43%.

  7. Performance Charts for a Turbojet System

    NASA Technical Reports Server (NTRS)

    Karp, Irving M.

    1947-01-01

    Convenient charts are presented for computing the thrust, fuel consumption, and other performance values of a turbojet system. These charts take into account the effects of ram pressure, compressor pressure ratio, ratio of combustion-chamber-outlet temperature to atmospheric temperature, compressor efficiency, turbine efficiency, combustion efficiency, discharge-nozzle coefficient, losses in total pressure in the inlet to the jet-propulsion unit and in the combustion chamber, and variation in specific heats with temperature. The principal performance charts show clearly the effects of the primary variables and correction charts provide the effects of the secondary variables. The performance of illustrative cases of turbojet systems is given. It is shown that maximum thrust per unit mass rate of air flow occurs at a lower compressor pressure ratio than minimum specific fuel consumption. The thrust per unit mass rate of air flow increases as the combustion-chamber discharge temperature increases. For minimum specific fuel consumption, however, an optimum combustion-chamber discharge temperature exists, which in some cases may be less than the limiting temperature imposed by the strength temperature characteristics of present materials.

  8. Thermodynamic analyses and the experimental validation of the Pulse Tube Expander system

    NASA Astrophysics Data System (ADS)

    Jia, Qiming; Gong, Linghui; Feng, Guochao; Zou, Longhui

    2018-04-01

    A Pulse Tube Expander (PTE) for small and medium capacity cryogenic refrigeration systems is described in this paper. An analysis of the Pulse Tube Expander is developed based on the thermodynamic analyses of the system. It is shown that the gas expansion is isentropic in the cold end of the pulse tube. The temperature variation at the outlet of Pulse Tube Expander is measured and the isentropic efficiency is calculated to be 0.455 at 2 Hz. The pressure oscillations in the pulse tube are obtained at different frequencies. The limitations and advantages of this system are also discussed.

  9. Community Alcohol Outlet Density and Underage Drinking

    PubMed Central

    Chen, Meng-Jinn; Grube, Joel W.; Gruenewald, Paul J.

    2009-01-01

    Aim This study examined how community alcohol outlet density may be associated with drinking among youths. Methods Longitudinal data were collected from 1091 adolescents (aged 14–16 at baseline) recruited from 50 zip codes in California with varying levels of alcohol outlet density and median household income. Hierarchical linear models were used to examine the associations between zip code alcohol outlet density and frequency rates of general alcohol use and excessive drinking, taking into account zip code median household income and individual-level variables (age, gender, race/ethnicity, personal income, mobility, and perceived drinking by parents and peers). Findings When all other factors were controlled, higher initial levels of drinking and excessive drinking were observed among youths residing in zip codes with higher alcohol outlet densities. Growth in drinking and excessive drinking was on average more rapid in zip codes with lower alcohol outlet densities. The relation of zip code alcohol outlet density with drinking appeared to be mitigated by having friends with access to a car. Conclusion Alcohol outlet density may play a significant role in initiation of underage drinking during early teen ages, especially when youths have limited mobility. Youth who reside in areas with low alcohol outlet density may overcome geographic constraints through social networks that increase their mobility and the ability to seek alcohol and drinking opportunities beyond the local community. PMID:20078485

  10. Steam conversion of liquefied petroleum gas and methane in microchannel reactor

    NASA Astrophysics Data System (ADS)

    Dimov, S. V.; Gasenko, O. A.; Fokin, M. I.; Kuznetsov, V. V.

    2018-03-01

    This study presents experimental results of steam conversion of liquefied petroleum gas and methane in annular catalytic reactor - heat exchanger. The steam reforming was done on the Rh/Al2O3 nanocatalyst with the heat applied through the microchannel gap from the outer wall. Concentrations of the products of chemical reactions in the outlet gas mixture are measured at different temperatures of reactor. The range of channel wall temperatures at which the ratio of hydrogen and carbon oxide in the outlet mixture grows substantially is determined. Data on the composition of liquefied petroleum gas conversion products for the ratio S/C = 5 was received for different GHVS.

  11. Process and continuous apparatus for chemical conversion of materials

    DOEpatents

    Rugg, Barry; Stanton, Robert

    1983-01-01

    A process and apparatus for the acid hydrolysis of waste cellulose to glucose of the type wherein waste cellulose is continuously fed into an inlet port of a twin screw extruder, water is continuously fed into reaction zone in the extruder, downstream of the inlet port, the cellulose is continuously reacted with water in the presence of an acid catalyst at elevated temperature and pressure in the reaction zone while being continuously conveyed to an outlet port of the extruder having a given diameter and the reacted cellulose is discharged from the extruder while the elevated temperature and pressure in the reaction zone is maintained. The elevated pressure is maintained by forming a dynamic seal zone at the upstream end of the reaction and continuously discharging the reacted material downstream of the outlet port at a predetermined volume rate of flow to maintain the pressure by passing the discharge through an orifice pipe having a smaller diameter than the given diameter of the outlet port.

  12. High performance internal reforming unit for high temperature fuel cells

    DOEpatents

    Ma, Zhiwen [Sandy Hook, CT; Venkataraman, Ramakrishnan [New Milford, CT; Novacco, Lawrence J [Brookfield, CT

    2008-10-07

    A fuel reformer having an enclosure with first and second opposing surfaces, a sidewall connecting the first and second opposing surfaces and an inlet port and an outlet port in the sidewall. A plate assembly supporting a catalyst and baffles are also disposed in the enclosure. A main baffle extends into the enclosure from a point of the sidewall between the inlet and outlet ports. The main baffle cooperates with the enclosure and the plate assembly to establish a path for the flow of fuel gas through the reformer from the inlet port to the outlet port. At least a first directing baffle extends in the enclosure from one of the sidewall and the main baffle and cooperates with the plate assembly and the enclosure to alter the gas flow path. Desired graded catalyst loading pattern has been defined for optimized thermal management for the internal reforming high temperature fuel cells so as to achieve high cell performance.

  13. 40 CFR Table 3 to Subpart Ppppp of... - Requirements for Initial Compliance Demonstrations

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... with . . . You must . . . Using . . . According to the following requirements . . . 1. The CO or THC outlet concentration emission limitation a. Demonstrate CO or THC emissions are 20 ppmvd or less i. EPA... CFR part 60 for THC measurement; or You must demonstrate that the outlet concentration of CO or THC...

  14. 40 CFR Table 3 to Subpart Ppppp of... - Requirements for Initial Compliance Demonstrations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... with . . . You must . . . Using . . . According to the following requirements . . . 1. The CO or THC outlet concentration emission limitation a. Demonstrate CO or THC emissions are 20 ppmvd or less i. EPA... CFR part 60 for THC measurement; or You must demonstrate that the outlet concentration of CO or THC...

  15. 40 CFR Table 3 to Subpart Ppppp of... - Requirements for Initial Compliance Demonstrations

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... with . . . You must . . . Using . . . According to the following requirements . . . 1. The CO or THC outlet concentration emission limitation a. Demonstrate CO or THC emissions are 20 ppmvd or less i. EPA... CFR part 60 for THC measurement; or You must demonstrate that the outlet concentration of CO or THC...

  16. 40 CFR Table 3 to Subpart Ppppp of... - Requirements for Initial Compliance Demonstrations

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... with . . . You must . . . Using . . . According to the following requirements . . . 1. The CO or THC outlet concentration emission limitation a. Demonstrate CO or THC emissions are 20 ppmvd or less i. EPA... CFR part 60 for THC measurement; or You must demonstrate that the outlet concentration of CO or THC...

  17. 40 CFR Table 3 to Subpart Ppppp of... - Requirements for Initial Compliance Demonstrations

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... with . . . You must . . . Using . . . According to the following requirements . . . 1. The CO or THC outlet concentration emission limitation a. Demonstrate CO or THC emissions are 20 ppmvd or less i. EPA... CFR part 60 for THC measurement; or You must demonstrate that the outlet concentration of CO or THC...

  18. Valve health monitoring system utilizing smart instrumentation

    NASA Astrophysics Data System (ADS)

    Jensen, Scott L.; Drouant, George J.

    2006-05-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are: cryogenic cycles, total cycles, inlet temperature, outlet temperature, body temperature, torsional strain, linear bonnet strain, preload position, total travel, and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commissions requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates related data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 Enclosures are used to house the base-station.

  19. Tobacco outlet density near home and school: Associations with smoking and norms among US teens

    PubMed Central

    Schleicher, Nina C.; Johnson, Trent O.; Fortmann, Stephen P.; Henriksen, Lisa

    2016-01-01

    This study examined whether living or going to school in neighborhoods with higher tobacco outlet density is associated with higher odds of cigarette smoking among teens, and with perceptions of greater smoking prevalence and peer approval. Using an Internet panel that is representative of US households, we matched data from teen-parent pairs (n=2,771, surveyed June 2011– December 2012) with environmental data about home and school neighborhoods. Density was measured as the number of tobacco outlets per square mile for a ½-mile roadway service area around each participant’s home and school. Logistic regressions tested relationships between tobacco outlet density near home and schools with ever smoking. Linear regressions tested relationships between density, perceived prevalence and peer approval. Models were adjusted for teen, parent/household and neighborhood characteristics. In total, 41.0% of US teens (ages 13–16) lived within ½ mile of a tobacco outlet, and 44.4% attended school within 1,000 feet of a tobacco outlet. Higher tobacco outlet density near home was associated with higher odds of ever smoking, although the relationship was small, OR=1.01, 95% CI (1.00,1.02). Higher tobacco outlet density near home was also associated with perceptions that more adults smoked, coef.=0.09, 95% CI (0.01,0.17). Higher tobacco outlet density near schools was not associated with any outcomes. Living in neighborhoods with higher tobacco outlet density may contribute to teen smoking by increasing access to tobacco products and by cultivating perceptions that smoking is more prevalent. Policy interventions to restrict tobacco outlet density should not be limited to school environments. PMID:27569829

  20. Tobacco outlet density near home and school: Associations with smoking and norms among US teens.

    PubMed

    Schleicher, Nina C; Johnson, Trent O; Fortmann, Stephen P; Henriksen, Lisa

    2016-10-01

    This study examined whether living or going to school in neighborhoods with higher tobacco outlet density is associated with higher odds of cigarette smoking among teens, and with perceptions of greater smoking prevalence and peer approval. Using an Internet panel that is representative of US households, we matched data from teen-parent pairs (n=2771, surveyed June 2011-December 2012) with environmental data about home and school neighborhoods. Density was measured as the number of tobacco outlets per square mile for a ½-mile roadway service area around each participant's home and school. Logistic regressions tested relationships between tobacco outlet density near home and schools with ever smoking. Linear regressions tested relationships between density, perceived prevalence and peer approval. Models were adjusted for teen, parent/household and neighborhood characteristics. In total, 41.0% of US teens (ages 13-16) lived within ½ mile of a tobacco outlet, and 44.4% attended school within 1000ft of a tobacco outlet. Higher tobacco outlet density near home was associated with higher odds of ever smoking, although the relationship was small, OR=1.01, 95% CI (1.00, 1.02). Higher tobacco outlet density near home was also associated with perceptions that more adults smoked, coef.=0.09, 95% CI (0.01, 0.17). Higher tobacco outlet density near schools was not associated with any outcomes. Living in neighborhoods with higher tobacco outlet density may contribute to teen smoking by increasing access to tobacco products and by cultivating perceptions that smoking is more prevalent. Policy interventions to restrict tobacco outlet density should not be limited to school environments. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Numerical Simulation of the Thermal Process in a W-Shape Radiant Tube Burner

    NASA Astrophysics Data System (ADS)

    Wang, Yi; Li, Jiyong; Zhang, Lifeng; Ling, Haitao; Li, Yanlong

    2014-07-01

    In the current work, three-dimensional mathematical models were developed for the heat transfer and combustion in a W-shape radiant tube burner (RTB) and were solved using Fluent software (ANSYS Inc., Canonsburg, PA). The standard k- ɛ model, nonpremixed combustion model, and the discrete ordinate model were used for the modeling of turbulence, combustion, and radiant heat transfer, respectively. In addition, the NO x postprocessor was used for the prediction of the NO emission. A corresponding experiment was performed for the validation of mathematical models. The details of fluid flow, heat transfer, and combustion in the RTB were investigated. Moreover, the effect of the air/fuel ratio (A/F) and air staging on the performance of RTB was studied with the reference indexes including heat efficiency, maximum temperature difference on shell wall, and NO emission at the outlet. The results indicated that a low speed zone formed in the vicinity of the combustion chamber outlet, and there were two relative high-temperature zones in the RTB, one in combustion chamber that favored the flame stability and the other from the main flame in the RTB. The maximum temperature difference was 95.48 K. As the A/F increased, the temperature increased first and then decreased. As the ratio of the primary to secondary air increased, the recirculation zone at the outlet of combustion chamber shrank gradually to disappear, and the flame length was longer and the temperature in flame decreased correspondingly.

  2. Socioeconomic area disparities in tobacco retail outlet density: a Western Australian analysis.

    PubMed

    Wood, Lisa J; Pereira, Gavin; Middleton, Nick; Foster, Sarah

    2013-05-20

    To examine the association between tobacco outlet density and area socioeconomic status (SES) in Western Australia. Ecological cross-sectional study investigating the relationship between the area SES of, and the density of tobacco retail outlets in, WA suburbs and towns for the Perth metropolitan area, and at the regional and state level. SES was determined using the 2006 Australian Bureau of Statistics Index of Relative Socioeconomic Advantage and Disadvantage (IRSAD) and classified into quartiles (very low, low, high and very high); tobacco outlet data were sourced from the WA Department of Health register of retailers licensed to sell tobacco at May 2011. Tobacco outlet density rate (per 10 000 residents). In WA overall, suburbs and towns with a very low IRSAD had more than four times the number of tobacco outlets compared with those with a very high IRSAD (P> < 0.001). This trend was similar when analyses were restricted to the Perth metropolitan area and to regional areas. Suburbs and towns in regional WA with a very low IRSAD had more than five times the number of tobacco outlets than those with a very high IRSAD (P> < 0.001). This study provides the first Australian evidence of a strong relationship between area SES and tobacco outlet density. Findings are consistent with a number of United States studies that report higher tobacco outlet densities in lower SES or minority neighbourhoods. The results underscore the importance of policy approaches to limit the number of tobacco retail licences granted, and to reduce the geographic density of outlets in more disadvantaged suburbs and towns.

  3. Decreasing the exhaust outlet temperatures on a class III bus with the lowest impact on the exhaust backpressure and the fuel consumption

    NASA Astrophysics Data System (ADS)

    Aslan, E.; Ozturk, Y.; Dileroglu, S.

    2017-07-01

    The focus of this study is to determine the most appropriate exhaust tail pipe form among three different type of designs with respect to their temperature loss efficiency for a 9.5m intercity bus equipped with an Euro VI diesel engine and an automated transmission. To provide lower temperatures at the exhaust outlet, mentioned designs were submitted on to a CFD simulation using Ansys Fluent 17.1, while for manufactured products, temperature measurement tests were conducted in an environmental chamber with Omega K-type thermocouples, and Flir T420 thermal camera was used to monitor outer surface temperature distributions to make a comparison between theoretical and practical results. In order to obtain these practical results, actual tests were performed in an environmental chamber with a constant ambient temperature during the vehicle exhaust emission system regeneration process. In conclusion, an exhaust tail pipe design with a diffuser having a circular contraction and expansion forms is designated since it was the most optimized option in terms of temperature loss efficiency, inconsiderable exhaust backpressure increase and manufacturing costs.

  4. Off-premise alcohol outlet characteristics and violence.

    PubMed

    Snowden, Aleksandra J; Pridemore, William Alex

    2014-07-01

    There is considerable evidence of an association between alcohol outlet density and violence. Although prior research reveals the importance of specific characteristics of bars on this association and that the relationship between bar density and violence may be moderated by these characteristics, there are few similar studies of the characteristics of off-premise outlets (e.g., liquor and convenience stores). We examined whether immediate environment, business practice, staff, and patron characteristics of off-premise alcohol outlets are associated with simple and aggravated assault density. Cross-sectional design using aggregate data from 65 census block groups in a non-metropolitan college town, systematic social observation, and spatial modeling techniques. We found limited effects of immediate environment, business practice, staff, and patron characteristics on simple assault density and no effect on aggravated assault density. Only two out of 17 characteristics were associated with simple assault density (i.e., nearby library and male patrons). This is the first study to examine the association between several off-premise alcohol outlet characteristics and assault. Our findings suggest that where the off-premise outlets are located, how well the immediate environment is maintained, what types of beverages the outlets sell, who visits them, and who works there matter little in their association with violence. This suggests the importance of outlet density itself as a primary driver of any association with violence. Public policies aimed at reducing alcohol outlet density or clustering may be useful for reducing violence.

  5. Velocity profile of water vapor inside a cavity with two axial inlets and two outlets

    NASA Astrophysics Data System (ADS)

    Guadarrama-Cetina, José; Ruiz Chavarría, Gerardo

    2014-03-01

    To study the dynamics of Breath Figure phenomenon, a control of both the rate of flow and temperature of water vapor is required. The experimental setup widely used is a non hermetically closed chamber with cylindrical geometry and axial inlets and outlets. In this work we present measurements in a cylindrical chamber with diameter 10 cm and 1.5 cm height, keeping a constant temperature (10 °C). We are focused in the velocity field when a gradient of the temperatures is produced between the base plate and the vapor. With a flux of water vapor of 250 mil/min at room temperature (21 °C), the Reynolds number measured in one inlet is 755. Otherwise, the temperatures of water vapor varies from 21 to 40 °C. The velocity profile is obtained by hot wire anemometry. We identify the stagnations and the possibly instabilities regions for an empty plate and with a well defined shape obstacle as a fashion sample. Facultad de Ciencias, UNAM.

  6. Wick wetting for water condensation systems

    DOEpatents

    Hering, Susanne Vera; Spielman, Steven Russel; Lewis, Gregory Stephen; Kreisberg, Nathan Michael

    2017-04-04

    A system and method for particle enlargement with continuously wetted wicks includes a container into which a flow of particle-laden air is introduced in a laminar manner through an inlet and to an outlet. The container has a first section, a second section and a third section though which the particle-laden air flows between the inlet and the outlet. The temperature of the second section is warmer than that of the first section at the inlet and the third section at the outlet. In one embodiment, a continuous wick spanning an interior wall of the first second, second section and third section, said wick being capable of internally transporting liquid water along its length is provided.

  7. Airway humidification with a heated wire humidifier during high-frequency ventilation using Babylog 8000 plus in neonates.

    PubMed

    Nagaya, Ken; Okamoto, Toshio; Nakamura, Eiki; Hayashi, Tokitsugi; Fujieda, Kenji

    2009-03-01

    Little data are available on airway humidity during high-frequency ventilation (HFV). Our purpose is to evaluate the airway humidification during HFV. We examined the airway humidification and temperature in a neonatal HFV system using Babylog 8000 plus. The absolute humidity (AH), relative humidity (RH), and temperature at different sites and under different HFV conditions were compared with those during conventional intermittent positive pressure ventilation (IPPV). The mean AH and RH at the patient end of the respiratory circuit under 37 degrees C in the humidification chamber (HC) during HFV were less than 35 mg/L and 65%, respectively, while those during IPPV were 42.3 mg/L and 96.8%, respectively. The humidification at the outlet of the HC was similar results. Moreover, during HFV an increase in the bias-flow of ventilator led to a further decrease in the humidity at the patient end of respiratory circuit and the outlet of HC. It was necessary to set the temperature in the HC at >39 degrees C to maintain adequate humidity at the HC and the patient end of respiratory circuit during HFV. An increase in the incubator temperature led to an increase in the temperature at the patient end of the respiratory circuit. The temperature at the patient end of the respiratory circuit was about 39-40 degrees C when the incubator temperature was 35-37 degrees C. The airway humidification at the patient end of respiratory circuit and the outlet of HC in HFV were poorer than those in IPPV. However, the adequacy of humidification and safety in HFV remain to be demonstrated in clinical practice.

  8. 40 CFR 63.4362 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... applicable, during each test run. (b) Measure the volatile organic matter concentration as carbon at the... limit, only the outlet volatile organic matter concentration must be determined. The outlet volatile organic matter concentration is determined as the average of the three test runs. (1) Use Method 25 if the...

  9. 40 CFR 63.4362 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... applicable, during each test run. (b) Measure the volatile organic matter concentration as carbon at the... limit, only the outlet volatile organic matter concentration must be determined. The outlet volatile organic matter concentration is determined as the average of the three test runs. (1) Use Method 25 if the...

  10. 40 CFR 63.4362 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... applicable, during each test run. (b) Measure the volatile organic matter concentration as carbon at the... limit, only the outlet volatile organic matter concentration must be determined. The outlet volatile organic matter concentration is determined as the average of the three test runs. (1) Use Method 25 if the...

  11. 40 CFR 63.4362 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... applicable, during each test run. (b) Measure the volatile organic matter concentration as carbon at the... limit, only the outlet volatile organic matter concentration must be determined. The outlet volatile organic matter concentration is determined as the average of the three test runs. (1) Use Method 25 if the...

  12. 30 CFR 7.97 - Application requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... internal parts, exhaust inlet and outlet, sensors, and the exhaust gas path through the exhaust conditioner... temperature sensor setting and exhaust gas temperature sensor setting used to meet the performance... sensors, flame arresters, exhaust conditioner, emergency intake air shutoff device, automatic fuel shutoff...

  13. 30 CFR 7.97 - Application requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... internal parts, exhaust inlet and outlet, sensors, and the exhaust gas path through the exhaust conditioner... temperature sensor setting and exhaust gas temperature sensor setting used to meet the performance... sensors, flame arresters, exhaust conditioner, emergency intake air shutoff device, automatic fuel shutoff...

  14. Tobacco retail outlet density and risk of youth smoking in New Zealand.

    PubMed

    Marsh, Louise; Ajmal, Ali; McGee, Rob; Robertson, Lindsay; Cameron, Claire; Doscher, Crile

    2016-12-01

    Evidence suggests inconsistent findings on the relationship between density of tobacco outlets around schools and risk of smoking among students. This study examines the density of tobacco outlets around secondary schools in New Zealand (NZ) and current smoking, experimental smoking, susceptibility to smoking, and attempted and successful tobacco purchasing. Smoking data came from the 2012 ASH Year 10 survey, a national survey of youth smoking in NZ. Geographic Information Systems were used to map tobacco retail outlets; a layer of secondary school locations was obtained from Koordinates.com. Logistic regression examined the relationship between density of outlets around schools and smoking behaviours, adjusting for individual-level and school-level confounders. Of the 27 238 students surveyed, 3.5% (952) were current smokers, 4.1% (n=1 128) were experimental smokers, and 39.8% (10 454) of nonsmokers were susceptible to smoking. An inverse relationship was found between the density of tobacco retail outlets and current smoking. Current smokers were significantly more likely to attempt to purchase tobacco if the density of tobacco retail outlets around their school was high. Non-smoking students were more likely to be susceptible to smoking if the density of tobacco outlets around their school was high. There was no statistically significant association between density of tobacco outlets and successful purchasing, nor experimental smoking. Restricting the permitted density of tobacco retail outlets around schools should be part of comprehensive tobacco control. In this regard, both smokers and non-smokers support the introduction of increased regulation of the tobacco retail environment to achieve our national smoke-free 2025 goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. 40 CFR 63.5535 - What performance tests and other procedures must I use?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Determine the net heating value of the gas being combusted using the techniques specified in § 63.11(b)(6... condensers, record the outlet (product side) gas or condensed liquid temperature averaged over the same... the temperature sensor in a position that provides a representative temperature. (3) For thermal...

  16. 40 CFR 63.5535 - What performance tests and other procedures must I use?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Determine the net heating value of the gas being combusted using the techniques specified in § 63.11(b)(6... condensers, record the outlet (product side) gas or condensed liquid temperature averaged over the same... the temperature sensor in a position that provides a representative temperature. (3) For thermal...

  17. Self-defrosting recuperative air-to-air heat exchanger

    DOEpatents

    Drake, Richard L.

    1993-01-01

    A heat exchanger includes a stationary spirally or concentrically wound heat exchanger core with rotating baffles on upper and lower ends thereof. The rotating baffles include rotating inlets and outlets which are in communication with respective fixed inlets and outlets via annuli. The rotation of the baffles causes a concurrent rotation of the temperature distribution within the stationary exchanger core, thereby preventing frost build-up in some applications and preventing the formation of hot spots in other applications.

  18. Effect of the thermal environment on the efficiency of packed columns in supercritical fluid chromatography.

    PubMed

    Zauner, Jordan; Lusk, Ryan; Koski, Steven; Poe, Donald P

    2012-11-30

    When a packed column is operated at temperatures and pressures near the critical point in supercritical fluid chromatography, the thermal environment in which it is placed has a significant impact on retention and efficiency. We measured the retention factors, plate heights, and related parameters for elution of a test mixture of alkylbenzenes with 5% methanol/95% carbon dioxide mobile phase on a 250 mm × 4.6 mm i.d. column packed with 5-micron Luna-C18 particles. Separations were performed at outlet pressures from 100 to 150 bar and a column oven temperature of 323K. For a bare column thermostated with convective air, significant efficiency losses were observed for outlet pressures equal to or less than 120 bar. These large efficiency losses are attributed to radial temperature gradients. Addition of foam insulation resulted in significant improvements in efficiency. Operating the column in still air using a commercially available column heater provided the best overall performance, with no measurable efficiency loss over the entire range of pressures studied. A reduced plate height of 1.88 was obtained at an optimum flow rate of 3.0 mL/min at 100 bar outlet pressure and with the temperature of the incoming mobile phase set approximately 2.3K above the temperature of the column oven. Retention time repeatability for all three thermal conditions was equal to or less than 0.5% RSD. These results demonstrate that it is possible to perform fast, efficient separations with excellent repeatability using SFC under near-critical conditions if the thermal environment is optimized to minimize the generation of radial temperature gradients. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Turbine system

    DOEpatents

    McMahan, Kevin Weston; Dillard, Daniel Jackson

    2016-05-03

    A turbine system is disclosed. The turbine system includes a transition duct having an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The turbine system further includes a turbine section connected to the transition duct. The turbine section includes a plurality of shroud blocks at least partially defining a hot gas path, a plurality of buckets at least partially disposed in the hot gas path, and a plurality of nozzles at least partially disposed in the hot gas path. At least one of a shroud block, a bucket, or a nozzle includes means for withstanding high temperatures.

  20. Shape Memory Actuated Normally Open Permanent Isolation Valve

    NASA Technical Reports Server (NTRS)

    Ramspacher, Daniel J. (Inventor); Bacha, Caitlin E. (Inventor)

    2017-01-01

    A valve assembly for an in-space propulsion system includes an inlet tube, an outlet tube, a valve body coupling the inlet tube to the outlet tube and defining a propellant flow path, a valve stem assembly disposed within the valve body, an actuator body coupled to the valve body, the valve stem assembly extending from an interior of the valve body to an interior of the actuator body, and an actuator assembly disposed within the actuator body and coupled to the valve stem assembly, the actuator assembly including a shape memory actuator member that when heated to a transition temperature is configured to enable the valve stem assembly to engage the outlet tube and seal the propellant flow path.

  1. A longitudinal analysis of alcohol outlet density and domestic violence.

    PubMed

    Livingston, Michael

    2011-05-01

    A small number of studies have identified a positive relationship between alcohol outlet density and domestic violence. These studies have all been based on cross-sectional data and have been limited to the assessment of ecological correlations between outlet density and domestic violence rates. This study provides the first longitudinal examination of this relationship. Cross-sectional time-series using aggregated data from small areas. The relationships between alcohol outlet density and domestic violence were assessed over time using a fixed-effects model. Controls for the spatial autocorrelation of the data were included in the model. The study uses data for 186 postcodes from within the metropolitan area of Melbourne, Australia for the years 1996 to 2005. Alcohol outlet density measures for three different types of outlets (hotel/pub, packaged liquor, on-premise) were derived from liquor licensing records and domestic violence rates were calculated from police-recorded crime data, based on the victim's postcode. Alcohol outlet density was associated significantly with rates of domestic violence, over time. All three licence categories were positively associated with domestic violence rates, with small effects for general (pub) and on-premise licences and a large effect for packaged liquor licences. In Melbourne, the density of liquor licences is positively associated with rates of domestic violence over time. The effects were particularly large for packaged liquor outlets, suggesting a need for licensing policies that pay more attention to o off-premise alcohol availability. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  2. 40 CFR 61.356 - Recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... test protocol and the means by which sampling variability and analytical variability were accounted for... also establish the design minimum and average temperature in the combustion zone and the combustion... the design minimum and average temperatures across the catalyst bed inlet and outlet. (C) For a boiler...

  3. 40 CFR 89.405 - Recorded information.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... temperature outlet. (10) Engine fuel inlet temperature at the pump inlet. (f) Test data; post-test. (1...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test..., where applicable, for each test. (b) Engine description and specification. A copy of the information...

  4. 40 CFR 89.405 - Recorded information.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... temperature outlet. (10) Engine fuel inlet temperature at the pump inlet. (f) Test data; post-test. (1...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test..., where applicable, for each test. (b) Engine description and specification. A copy of the information...

  5. 40 CFR 89.405 - Recorded information.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... temperature outlet. (10) Engine fuel inlet temperature at the pump inlet. (f) Test data; post-test. (1...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test..., where applicable, for each test. (b) Engine description and specification. A copy of the information...

  6. 40 CFR 89.405 - Recorded information.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... temperature outlet. (10) Engine fuel inlet temperature at the pump inlet. (f) Test data; post-test. (1...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test..., where applicable, for each test. (b) Engine description and specification. A copy of the information...

  7. 40 CFR 89.405 - Recorded information.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... temperature outlet. (10) Engine fuel inlet temperature at the pump inlet. (f) Test data; post-test. (1...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test..., where applicable, for each test. (b) Engine description and specification. A copy of the information...

  8. Compliant Metal Enhanced Convection Cooled Reverse-Flow Annular Combustor

    NASA Technical Reports Server (NTRS)

    Paskin, Marc D.; Acosta, Waldo A.

    1994-01-01

    A joint Army/NASA program was conducted to design, fabricate, and test an advanced, reverse-flow, small gas turbine combustor using a compliant metal enhanced (CME) convection wall cooling concept. The objectives of this effort were to develop a design method (basic design data base and analysis) for the CME cooling technique and tben demonstrate its application to an advanced cycle, small, reverse-flow combustor with 3000 F (1922 K) burner outlet temperature (BOT). The CME concept offers significant improvements in wall cooling effectiveness resulting in a large reduction in cooling air requirements. Therefore, more air is available for control of burner outlet temperature pattern in addition to the benefit of improved efficiency, reduced emissions, and smoke levels. Rig test results demonstrated the benefits and viability of the CME concept meeting or exceeding the aerothermal performance and liner wall temperature characteristics of similar lower temperature-rise combustors, achieving 0.15 pattern factor at 3000 F (1922 K) BOT, while utilizing approximately 80 percent less cooling air than conventional, film-cooled combustion systems.

  9. Insights into ice-ocean interactions and fjord circulation from fjord sea surface temperatures at the Petermann Glacier, Greenland

    NASA Astrophysics Data System (ADS)

    Snow, T.; Shepherd, B.; Abdalati, W.; Scambos, T. A.

    2016-12-01

    Dynamic processes at marine-terminating outlet glaciers are responsible for over one-third of Greenland Ice Sheet (GIS) mass loss. Enhanced intrusion of warm ocean waters at the termini of these glaciers has contributed to elevated rates of ice thinning and terminus retreat over the last two decades. In situ oceanographic measurements and modeling studies show that basal melting of glaciers and subglacial discharge can cause buoyant plumes of water to rise to the fjord surface and influence fjord circulation characteristics. The temperature of these surface waters holds clues about ice-ocean interactions and small-scale circulation features along the glacier terminus that could contribute to outlet glacier mass loss, but the magnitude and duration of temperature variability remains uncertain. Satellite remote sensing has proven very effectiver for acquiring sea surface temperatuer (SST) data from these remote regions on a long-term, consistent basis and shows promise for identifying temperature anomalies at the ice front. However, these data sets have not been widely utilized to date. Here, we use satellite-derived sea surface temperatures to identify fjord surface outflow characteristics from 2000 to present at the Petermann Glacier, which drains 4% of the GIS and is experiencing 80% of its mass loss from basal melt. We find a general SST warming trend that coincides with early sea ice breakup and precedes two major calving events and ice speedup that began in 2010. Persistent SST anomalies along the terminus provide evidence of warm outflow that is consistent with buoyant plume model predictions. However, the anomalies are not evident early in the time series, suggesting that ocean inflow and ice-ocean interactions have experienced a regime shift since 2000. Our results provide valuable insight into fjord circulation patterns and the forcing mechanisms that contribute to terminus retreat. Comparing our results to ongoing modeling experiments, time series from other outlet glaciers, and coincident in situ measurements, will help to further explain the physical processes occurring at the ice-ocean boundary and provide useful insights into the changes taking place at other GIS marine-terminating outlet glaciers.

  10. A hydrothermal atomic force microscope for imaging in aqueous solution up to 150 °C

    NASA Astrophysics Data System (ADS)

    Higgins, Steven R.; Eggleston, Carrick M.; Knauss, Kevin G.; Boro, Carl O.

    1998-08-01

    We present the design of a contact atomic force microscope (AFM) that can be used to image solid surfaces in aqueous solution up to 150 °C and 6 atm. The main features of this unique AFM are: (1) an inert gas pressurized microscope base containing stepper motor for coarse advance and the piezoelectric tube scanner; (2) a chemically inert membrane separating these parts from the fluid cell; (3) a titanium fluid cell with fluid inlet-outlet ports, a thermocouple port, and a sapphire optical window; (4) a resistively heated ceramic booster heater for the fluid cell to maintain the temperature of solutions sourced from a hydrothermal bomb; and (5) mass flow control. The design overcomes current limitations on the temperature and pressure range accessible to AFM imaging in aqueous solutions. Images taken at temperature and pressure are presented, demonstrating the unit-cell scale (<1 nm) vertical resolution of the AFM under hydrothermal conditions.

  11. A Study on the Characteristics of Design Variables for IRSS Diffuser

    NASA Astrophysics Data System (ADS)

    Cho, Yong-Jin; Ko, Dae-Eun

    2017-11-01

    In modern naval ships, infrared signature suppression systems (IRSS) are installed to decrease the temperature of waste gas generated in propulsion engine and the metallic surface temperature of heated exhaust pipes. Generally, IRSS is composed of eductor, mixing tube, and diffuser. Diffuser serves to reduce the temperature by creating an air film using the pressure difference between internal gas and external air. In this study, design variables were selected by analyzing the diffuser and the characteristics of design variables that affect the performance of diffuser were examined using Taguchi experiment method. For the diffuser performance analysis, a heat flow analysis technique established in previous research was used. The IRSS performance evaluation was carried out based on the average area value of the metal surface temperature and the temperature of the exhaust gas at the outlet of the diffuser, which are variables directly related to the intensity of infrared signature in naval ships. It was verified that the exhaust gas temperature is greatly affected by changes in the diameter of the diffuser outlet, and the metal surface temperature of diffuser is greatly affected by changes in the number of diffuser rings.

  12. Contamination by Salmonella spp., Campylobacter spp. and Listeria spp. of most popular chicken- and pork-sausages sold in Reunion Island.

    PubMed

    Trimoulinard, A; Beral, M; Henry, I; Atiana, L; Porphyre, V; Tessier, C; Leclercq, A; Cardinale, E

    2017-06-05

    One of the most popular meat products of the local "cuisine" is sausage composed with 100% chicken or 100% pork. In this study, we aimed to determine the presence of Salmonella spp., Campylobacter spp. and Listeria spp. in chicken- and pork-sausages, quantify Salmonella spp. population and identify the factors that could be associated with contamination in the outlets. Two hundred and three batches of pork and chicken sausages were randomly collected from 67 local outlets (supermarkets, groceries and butcher shops). Salmonella spp. was detected in 11.8% (95% confidence interval (CI): [10.0; 13.5]) of samples, Campylobacter spp. in 1.5% [0.7; 4.2] and Listeria monocytogenes in 5.9% [4.4; 7.3]. Most probable number of Salmonella spp. varied between 6cfu per gram to 320cfu per gram. Salmonella serotypes isolated from pork and chicken sausages were S. Typhimurium (45.8%), S. London (20.8%), S. Derby (16.7%), S. Newport (8.33%), S. Blockley (4.2%) and S. Weltevreden (4.17%). Using a logistic (mixed-effect) regression model, we found that Salmonella spp. contamination was positively associated with sausages sold in papers or plastic bags and no control of rodents. Chicken sausages were associated with a decreasing risk of Salmonella contamination. Listeria monocytogenes contamination was positively associated with the presence of fresh rodent droppings in the outlet and negatively when the staff was cleaning regularly their hands with soap and water or water only. All the sampled outlets of Reunion Island were not equivalent in terms of food safety measures. Increasing awareness of these traders remains a cornerstone to limit the presence of Salmonella spp. and Listeria spp. in sausages, particularly in a tropical context (high temperature and humidity). Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Composite Matrix Cooling Scheme for Small Gas Turbine Combustors

    NASA Technical Reports Server (NTRS)

    Paskin, Marc D.; Ross, Phillip T.; Mongia, Hukam C.; Acosta, Waldo A.

    1990-01-01

    The design, manufacture, and testing of a compliant metal/ceramic (CMC) wall cooling concept-implementing combustor for small gas turbine engines has been undertaken by a joint U.S. Army/NASA technology development program. CMC in principle promises greater wall cooling effectiveness than conventional designs and materials, thereby facilitating a substantial reduction in combustor cooling air requirements and furnishing greater airflow for the control of burner outlet temperature patterns as well as improving thermodynamic efficiency and reducing pollutant emissions and smoke levels. Rig test results have confirmed the projected benefits of the CMC concept at combustor outlet temperatures of the order of 2460 F, at which approximately 80 percent less cooling air than conventionally required was being employed by the CMC combustor.

  14. Self-defrosting recuperative air-to-air heat exchanger

    DOEpatents

    Drake, R.L.

    1993-12-28

    A heat exchanger is described which includes a stationary spirally or concentrically wound heat exchanger core with rotating baffles on upper and lower ends thereof. The rotating baffles include rotating inlets and outlets which are in communication with respective fixed inlets and outlets via annuli. The rotation of the baffles causes a concurrent rotation of the temperature distribution within the stationary exchanger core, thereby preventing frost build-up in some applications and preventing the formation of hot spots in other applications. 3 figures.

  15. Validity of Secondary Retail Food Outlet Data

    PubMed Central

    Fleischhacker, Sheila E.; Evenson, Kelly R.; Sharkey, Joseph; Pitts, Stephanie B.J.; Rodriguez, Daniel A.

    2013-01-01

    Context Improving access to healthy foods is a promising strategy to prevent nutrition-related chronic diseases. To characterize retail food environments and identify areas with limited retail access, researchers, government programs, and community advocates have primarily used secondary retail food outlet data sources (e.g., InfoUSA or government food registries). To advance the state of the science on measuring retail food environments, this systematic review examined the evidence for validity reported for secondary retail food outlet data sources for characterizing retail food environments. Evidence acquisition A literature search was conducted through December 31, 2012 to identify peer-reviewed published literature that compared secondary retail food outlet data sources to primary data sources (i.e., field observations) for accuracy of identifying the type and location of retail food outlets. Data were analyzed in 2013. Evidence synthesis Nineteen studies met the inclusion criteria. The evidence for validity reported varied by secondary data sources examined, primary data–gathering approaches, retail food outlets examined, and geographic and sociodemographic characteristics. More than half of the studies (53%) did not report evidence for validity by type of food outlet examined and by a particular secondary data source. Conclusions Researchers should strive to gather primary data but if relying on secondary data sources, InfoUSA and government food registries had higher levels of agreement than reported by other secondary data sources and may provide sufficient accuracy for exploring these associations in large study areas. PMID:24050423

  16. Examining the validity and utility of two secondary sources of food environment data against street audits in England.

    PubMed

    Wilkins, Emma L; Radley, Duncan; Morris, Michelle A; Griffiths, Claire

    2017-12-20

    Secondary data containing the locations of food outlets is increasingly used in nutrition and obesity research and policy. However, evidence evaluating these data is limited. This study validates two sources of secondary food environment data: Ordnance Survey Points of Interest data (POI) and food hygiene data from the Food Standards Agency (FSA), against street audits in England and appraises the utility of these data. Audits were conducted across 52 Lower Super Output Areas in England. All streets within each Lower Super Output Area were covered to identify the name and street address of all food outlets therein. Audit-identified outlets were matched to outlets in the POI and FSA data to identify true positives (TP: outlets in both the audits and the POI/FSA data), false positives (FP: outlets in the POI/FSA data only) and false negatives (FN: outlets in the audits only). Agreement was assessed using positive predictive values (PPV: TP/(TP + FP)) and sensitivities (TP/(TP + FN)). Variations in sensitivities and PPVs across environment and outlet types were assessed using multi-level logistic regression. Proprietary classifications within the POI data were additionally used to classify outlets, and agreement between audit-derived and POI-derived classifications was assessed. Street audits identified 1172 outlets, compared to 1100 and 1082 for POI and FSA respectively. PPVs were statistically significantly higher for FSA (0.91, CI: 0.89-0.93) than for POI (0.86, CI: 0.84-0.88). However, sensitivity values were not different between the two datasets. Sensitivity and PPVs varied across outlet types for both datasets. Without accounting for this, POI had statistically significantly better PPVs in rural and affluent areas. After accounting for variability across outlet types, FSA had statistically significantly better sensitivity in rural areas and worse sensitivity in rural middle affluence areas (relative to deprived). Audit-derived and POI-derived classifications exhibited substantial agreement (p < 0.001; Kappa = 0.66, CI: 0.63-0.70). POI and FSA data have good agreement with street audits; although both datasets had geographic biases which may need to be accounted for in analyses. Use of POI proprietary classifications is an accurate method for classifying outlets, providing time savings compared to manual classification of outlets.

  17. Report on FY15 alloy 617 code rules development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sham, Sam; Jetter, Robert I; Hollinger, Greg

    2015-09-01

    Due to its strength at very high temperatures, up to 950°C (1742°F), Alloy 617 is the reference construction material for structural components that operate at or near the outlet temperature of the very high temperature gas-cooled reactors. However, the current rules in the ASME Section III, Division 5 Subsection HB, Subpart B for the evaluation of strain limits and creep-fatigue damage using simplified methods based on elastic analysis have been deemed inappropriate for Alloy 617 at temperatures above 650°C (1200°F) (Corum and Brass, Proceedings of ASME 1991 Pressure Vessels and Piping Conference, PVP-Vol. 215, p.147, ASME, NY, 1991). The rationalemore » for this exclusion is that at higher temperatures it is not feasible to decouple plasticity and creep, which is the basis for the current simplified rules. This temperature, 650°C (1200°F), is well below the temperature range of interest for this material for the high temperature gas-cooled reactors and the very high temperature gas-cooled reactors. The only current alternative is, thus, a full inelastic analysis requiring sophisticated material models that have not yet been formulated and verified. To address these issues, proposed code rules have been developed which are based on the use of elastic-perfectly plastic (EPP) analysis methods applicable to very high temperatures. The proposed rules for strain limits and creep-fatigue evaluation were initially documented in the technical literature (Carter, Jetter and Sham, Proceedings of ASME 2012 Pressure Vessels and Piping Conference, papers PVP 2012 28082 and PVP 2012 28083, ASME, NY, 2012), and have been recently revised to incorporate comments and simplify their application. Background documents have been developed for these two code cases to support the ASME Code committee approval process. These background documents for the EPP strain limits and creep-fatigue code cases are documented in this report.« less

  18. 40 CFR 1066.135 - Linearity verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CVS, double-dilution, and partial-flow systems. (3) PM sample. (4) Chiller sample, for gaseous sampling systems that use thermal chillers to dry samples, and that use chiller temperature to calculate dewpoint at the chiller outlet. For testing, if you choose to use the high alarm temperature setpoint for...

  19. Radiation intensification of the reactor pressure vessels recovery by low temperature heat treatment (wet annealing)

    NASA Astrophysics Data System (ADS)

    Krasikov, E.

    2015-04-01

    As a main barrier against radioactivity outlet reactor pressure vessel (RPV) is a key component in terms of NPP safety. Therefore present-day demands in RPV reliability enhance have to be met by all possible actions for RPV in-service embrittlement mitigation. Annealing treatment is known to be the effective measure to restore the RPV metal properties deteriorated by neutron irradiation. There are two approaches to annealing. The first one is so-called «dry» high temperature (∼475°C) annealing. It allows obtaining practically complete recovery, but requires the removal of the reactor core and internals. External heat source (furnace) is required to carry out RPV heat treatment. The alternative approach is to anneal RPV at a maximum coolant temperature which can be obtained using the reactor core or primary circuit pumps while operating within the RPV design limits. This low temperature «wet» annealing, although it cannot be expected to produce complete recovery, is more attractive from the practical point of view especially in cases when the removal of the internals is impossible.

  20. Wood-derived olefins by steam cracking of hydrodeoxygenated tall oils.

    PubMed

    Pyl, Steven P; Dijkmans, Thomas; Antonykutty, Jinto M; Reyniers, Marie-Françoise; Harlin, Ali; Van Geem, Kevin M; Marin, Guy B

    2012-12-01

    Tall oil fractions obtained from Norwegian spruce pulping were hydrodeoxygenated (HDO) at pilot scale using a commercial NiMo hydrotreating catalyst. Comprehensive two dimensional gas chromatography (GC×GC) showed that HDO of both tall oil fatty acids (TOFA) and distilled tall oil (DTO) produced highly paraffinic hydrocarbon liquids. The hydrotreated fractions also contained fatty acid methyl esters and norabietane and norabietatriene isomers. Steam cracking of HDO-TOFA in a pilot plant revealed that high light olefin yields can be obtained, with 35.4 wt.% of ethene and 18.2 wt.% of propene at a coil outlet pressure (COP) of 1.7 bara, a dilution of 0.45 kg(steam)/kg(HDO-TOFA) and a coil outlet temperature (COT) of 820 °C. A pilot plant coking experiment indicated that cracking of HDO-TOFA at a COT of 850 °C results in limited fouling in the reactor. Co-cracking of HDO tall oil fractions with a typical fossil-based naphtha showed improved selectivity to desired light olefins, further demonstrating the potential of large scale olefin production from hydrotreated tall oil fractions in conventional crackers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Microtextured Surfaces for Turbine Blade Impingement Cooling

    NASA Technical Reports Server (NTRS)

    Fryer, Jack

    2014-01-01

    Gas turbine engine technology is constantly challenged to operate at higher combustor outlet temperatures. In a modern gas turbine engine, these temperatures can exceed the blade and disk material limits by 600 F or more, necessitating both internal and film cooling schemes in addition to the use of thermal barrier coatings. Internal convective cooling is inadequate in many blade locations, and both internal and film cooling approaches can lead to significant performance penalties in the engine. Micro Cooling Concepts, Inc., has developed a turbine blade cooling concept that provides enhanced internal impingement cooling effectiveness via the use of microstructured impingement surfaces. These surfaces significantly increase the cooling capability of the impinging flow, as compared to a conventional untextured surface. This approach can be combined with microchannel cooling and external film cooling to tailor the cooling capability per the external heating profile. The cooling system then can be optimized to minimize impact on engine performance.

  2. Nuclear fuels - Present and future

    NASA Astrophysics Data System (ADS)

    Olander, D.

    2009-06-01

    The important developments in nuclear fuels and their problems are reviewed and compared with the status of present light-water reactor fuels. The limitations of LWR fuels are reviewed with respect to important recent concerns, namely provision of outlet coolant temperatures high enough for use in H 2 production, destruction of plutonium to eliminate proliferation concerns, and burning of the minor actinides to reduce the waste repository heat load and long-term radiation hazard. In addition to current oxide-based fuel rod designs, the hydride fuel with liquid-metal thermal bonding of the fuel-cladding gap is covered. Finally, two of the most promising Generation IV reactor concepts, the very high temperature reactor and the sodium fast reactor, and the accompanying reprocessing technologies, aqueous-based UREX+1a and pyrometallurgical, are summarized. In all of the topics covered, the thermodynamics involved in the fuel's behavior under irradiation and in the reprocessing schemes are emphasized.

  3. Data on microbial and physiochemical characteristics of inlet and outlet water from household water treatment devices in Rasht, Iran.

    PubMed

    Naghipour, Dariush; Ashrafi, Seyed Davoud; Mojtahedi, Ali; Vatandoost, Masoud; Hosseinzadeh, Loghman; Roohbakhsh, Esmail

    2018-02-01

    In this research, we measured various parameters related to drinking water quality include turbidity, temperature, pH, EC, TDS, Alkalinity, fecal and total coliform, heterotrophic plate count (HPC), free chlorine, Mn, Ca, Mg, Fe, Na, Cl - , F - , HCO 3 , in the inlet and outlet of household water treatment devices according to the standard methods for the examination of water and wastewater (W.E. Federation and Association and A.P.H., 2005) [1]. Sixty four inlet and outlet water samples were taken from thirty two household water treatment devices from eight different residential blocks in Golsar town of Rasht, Iran. The data obtained from experiments were analyzed using the software Special Package for Social Sciences (SPSS 24) and MS-Excel.

  4. Effect of flame-tube head structure on combustion chamber performance

    NASA Technical Reports Server (NTRS)

    Gu, Minqqi

    1986-01-01

    The experimental combustion performance of a premixed, pilot-type flame tube with various head structures is discussed. The test study covers an extensive area: efficiency of the combustion chamber, quality of the outlet temperature field, limit of the fuel-lean blowout, ignition performance at ground starting, and carbon deposition. As a result of these tests, a nozzle was found which fits the premixed pilot flame tube well. The use of this nozzle optimized the performance of the combustion chamber. The tested models had premixed pilot chambers with two types of air-film-cooling structures, six types of venturi-tube structures, and secondary fuel nozzles with two small spray-cone angles.

  5. 40 CFR 63.361 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... oxidation control device or at the exhaust point from the combustion chamber of a thermal oxidation control... scrubber achieves at least 99-percent control of ethylene oxide emissions. Oxidation temperature means the temperature at the outlet point of a catalytic oxidation unit control device or at the exhaust point from the...

  6. Impacts of rainfall and air temperature variations due to climate change upon hydrological characteristics: A case study

    Treesearch

    Ying Ouyang; Jia-En Zhang; Yide Li; Prem Parajuli; Gary Feng

    2015-01-01

    Rainfall and air temperature variations resulting from climate change are important driving forces to change hydrologic processes in watershed ecosystems. This study investigated the impacts of past and future rainfall and air temperature variations upon water discharge, water outflow (from the watershed outlet), and evaporative loss in the Lower Yazoo River Watershed...

  7. Alcohol Availability and Intimate Partner Violence Among US Couples

    PubMed Central

    McKinney, Christy M.; Caetano, Raul; Harris, Theodore Robert; Ebama, Malembe S.

    2008-01-01

    Objectives We examined the relation between alcohol outlet density (the number of alcohol outlets per capita by zip code) and male-to-female partner violence (MFPV) or female-to-male partner violence (FMPV). We also investigated whether binge drinking or the presence of alcohol-related problems altered the relationship between alcohol outlet density and MFPV or FMPV. Methods We linked individual and couple sociodemographic and behavioral data from a 1995 national population-based sample of 1,597 couples to alcohol outlet data and 1990 US Census sociodemographic information. We used logistic regression for survey data to estimate unadjusted and adjusted odds ratios between alcohol outlet density and MFPV or FMPV along with 95% confidence intervals (CIs) and p-values. We used a design-based Wald test to derive a p-value for multiplicative interaction to assess the role of binge drinking and alcohol-related problems. Results In adjusted analysis, an increase of one alcohol outlet per 10,000 persons was associated with a 1.03-fold increased risk of MFPV (p-value for linear trend = 0.01) and a 1.011-fold increased risk of FMPV (p-value for linear trend = 0.48). An increase of 10 alcohol outlets per 10,000 persons was associated with 34% and 12% increased risk of MFPV and FMPV respectively, though the CI for the association with FMPV was compatible with no increased risk. The relationship between alcohol outlet density and MFPV was stronger among couples reporting alcohol-related problems than those reporting no problems (p-value for multiplicative interaction = 0.01). Conclusions We found that as alcohol outlet density increases so does the risk of MFPV and that this relationship may differ for couples who do and do not report alcohol-related problems. Given that MFPV accounts for the majority of injuries related to intimate partner violence, policy makers may wish to carefully consider the potential benefit of limiting alcohol outlet density to reduce MFPV and its adverse consequences. PMID:18976345

  8. Alcohol availability and intimate partner violence among US couples.

    PubMed

    McKinney, Christy M; Caetano, Raul; Harris, Theodore Robert; Ebama, Malembe S

    2009-01-01

    We examined the relation between alcohol outlet density (the number of alcohol outlets per capita by zip code) and male-to-female partner violence (MFPV) or female-to-male partner violence (FMPV). We also investigated whether binge drinking or the presence of alcohol-related problems altered the relationship between alcohol outlet density and MFPV or FMPV. We linked individual and couple sociodemographic and behavioral data from a 1995 national population-based sample of 1,597 couples to alcohol outlet data and 1990 US Census sociodemographic information. We used logistic regression for survey data to estimate unadjusted and adjusted odds ratios between alcohol outlet density and MFPV or FMPV along with 95% confidence intervals (CIs) and p-values. We used a design-based Wald test to derive a p-value for multiplicative interaction to assess the role of binge drinking and alcohol-related problems. In adjusted analysis, an increase of one alcohol outlet per 10,000 persons was associated with a 1.03-fold increased risk of MFPV (p-value for linear trend = 0.01) and a 1.011-fold increased risk of FMPV (p-value for linear trend = 0.48). An increase of 10 alcohol outlets per 10,000 persons was associated with 34% and 12% increased risk of MFPV and FMPV respectively, though the CI for the association with FMPV was compatible with no increased risk. The relationship between alcohol outlet density and MFPV was stronger among couples reporting alcohol-related problems than those reporting no problems (p-value for multiplicative interaction = 0.01). We found that as alcohol outlet density increases so does the risk of MFPV and that this relationship may differ for couples who do and do not report alcohol-related problems. Given that MFPV accounts for the majority of injuries related to intimate partner violence, policy makers may wish to carefully consider the potential benefit of limiting alcohol outlet density to reduce MFPV and its adverse consequences.

  9. TRITIUM BARRIER MATERIALS AND SEPARATION SYSTEMS FOR THE NGNP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman, S; Thad Adams, T

    2008-07-17

    Contamination of downstream hydrogen production plants or other users of high-temperature heat is a concern of the Next Generation Nuclear Plant (NGNP) Project. Due to the high operating temperatures of the NGNP (850-900 C outlet temperature), tritium produced in the nuclear reactor can permeate through heat exchangers to reach the hydrogen production plant, where it can become incorporated into process chemicals or the hydrogen product. The concentration limit for tritium in the hydrogen product has not been established, but it is expected that any future limit on tritium concentration will be no higher than the air and water effluent limitsmore » established by the NRC and the EPA. A literature survey of tritium permeation barriers, capture systems, and mitigation measures is presented and technologies are identified that may reduce the movement of tritium to the downstream plant. Among tritium permeation barriers, oxide layers produced in-situ may provide the most suitable barriers, though it may be possible to use aluminized surfaces also. For tritium capture systems, the use of getters is recommended, and high-temperature hydride forming materials such as Ti, Zr, and Y are suggested. Tritium may also be converted to HTO in order to capture it on molecular sieves or getter materials. Counter-flow of hydrogen may reduce the flux of tritium through heat exchangers. Recommendations for research and development work are provided.« less

  10. FINAL REPORT INTEGRATED DM1200 MELTER TESTING OF BUBBLER CONFIGURATIONS USING HLW AZ-101 SIMULANTS VSL-04R4800-4 REV 0 10/5/04

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KRUGER AA; MATLACK KS; GONG W

    2011-12-29

    This report documents melter and off-gas performance results obtained on the DM1200 HLW Pilot Melter during processing of AZ-101 HLW simulants. The tests reported herein are a subset of six tests from a larger series of tests described in the Test Plan for the work; results from the other tests have been reported separately. The solids contents of the melter feeds were based on the WTP baseline value for the solids content of the feeds from pretreatment which changed during these tests from 20% to 15% undissolved solids resulting in tests conducted at two feed solids contents. Based on themore » results of earlier tests with single outlet 'J' bubblers, initial tests were performed with a total bubbling rate of 651 pm. The first set of tests (Tests 1A-1E) addressed the effects of skewing this total air flow rate back and forth between the two installed bubblers in comparison to a fixed equal division of flow between them. The second set of tests (2A-2D) addressed the effects of bubbler depth. Subsequently, as the location, type and number of bubbling outlets were varied, the optimum bubbling rate for each was determined. A third (3A-3C) and fourth (8A-8C) set of tests evaluated the effects of alternative bubbler designs with two gas outlets per bubbler instead of one by placing four bubblers in positions simulating multiple-outlet bubblers. Data from the simulated multiple outlet bubblers were used to design bubblers with two outlets for an additional set of tests (9A-9C). Test 9 was also used to determine the effect of small sugar additions to the feed on ruthenium volatility. Another set of tests (10A-10D) evaluated the effects on production rate of spiking the feed with chloride and sulfate. Variables held constant to the extent possible included melt temperature, plenum temperature, cold cap coverage, the waste simulant composition, and the target glass composition. The feed rate was increased to the point that a constant, essentially complete, cold cap was achieved, which was used as an indicator of a maximized feed rate for each test. The first day of each test was used to build the cold cap and decrease the plenum temperature. The remainder of each test was split into two- to six-day segments, each with a different bubbling rate, bubbler orientation, or feed concentration of chloride and sulfur.« less

  11. 40 CFR 1065.695 - Data requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... restriction. (v) Charge air cooler volume. (vi) Charge air cooler outlet temperature, specified engine.... (iii) “Dry-to-wet” correction. (iv) NMHC, CH4, and contamination correction. (v) NOX humidity...

  12. Thermal synthesis apparatus

    DOEpatents

    Fincke, James R [Idaho Falls, ID; Detering, Brent A [Idaho Falls, ID

    2009-08-18

    An apparatus for thermal conversion of one or more reactants to desired end products includes an insulated reactor chamber having a high temperature heater such as a plasma torch at its inlet end and, optionally, a restrictive convergent-divergent nozzle at its outlet end. In a thermal conversion method, reactants are injected upstream from the reactor chamber and thoroughly mixed with the plasma stream before entering the reactor chamber. The reactor chamber has a reaction zone that is maintained at a substantially uniform temperature. The resulting heated gaseous stream is then rapidly cooled by passage through the nozzle, which "freezes" the desired end product(s) in the heated equilibrium reaction stage, or is discharged through an outlet pipe without the convergent-divergent nozzle. The desired end products are then separated from the gaseous stream.

  13. Comparing CMIP-3 and CMIP-5 climate projections on flooding estimation of Devils Lake of North Dakota, USA

    PubMed Central

    2018-01-01

    Background Water level fluctuations in endorheic lakes are highly susceptible to even slight changes in climate and land use. Devils Lake (DL) in North Dakota, USA is an endorheic system that has undergone multi-decade flooding driven by changes in regional climate. Flooding mitigation strategies have centered on the release of lake water to a nearby river system through artificial outlets, resulting in legal challenges and environmental concerns related to water quality, downstream flooding, species migration, stakeholder opposition, and transboundary water conflicts between the US and Canada. Despite these drawbacks, running outlets would result in low overspill risks in the next 30 years. Methods In this study we evaluated the efficacy of this outlet-based mitigation strategy under scenarios based on the latest IPCC future climate projections. We used the Coupled Model Intercomparison Project CMIP-5 weather patterns from 17 general circulation models (GCMs) obtained under four representative concentration pathways (RCP) scenarios and downscaled to the DL region. Then, we simulated the changes in lake water levels using the soil and water assessment tool based hydrological model of the watershed. We estimated the probability of future flood risks under those scenarios and compared those with previously estimated overspill risks under the CMIP-3 climate. Results The CMIP-5 ensemble projected a mean annual temperature of 5.78 °C and mean daily precipitation of 1.42 mm/day; both are higher than the existing CMIP-3 future estimates of 4.98 °C and 1.40 mm/day, respectively. The increased precipitation and higher temperature resulted in a significant increase of DL’s overspill risks: 24.4–47.1% without release from outlets and 3.5–14.4% even if the outlets are operated at their combined full 17 m3/s capacity. Discussion The modeled increases in overspill risks indicate a greater frequency of water releases through the artificial outlets. Future risk mitigation management should include providing a flood warning signal to local resource managers, and tasking policy makers to identify additional solution measures such as land use management in the upper watershed to mitigate DL’s flooding. PMID:29736343

  14. Comparing CMIP-3 and CMIP-5 climate projections on flooding estimation of Devils Lake of North Dakota, USA.

    PubMed

    Kharel, Gehendra; Kirilenko, Andrei

    2018-01-01

    Water level fluctuations in endorheic lakes are highly susceptible to even slight changes in climate and land use. Devils Lake (DL) in North Dakota, USA is an endorheic system that has undergone multi-decade flooding driven by changes in regional climate. Flooding mitigation strategies have centered on the release of lake water to a nearby river system through artificial outlets, resulting in legal challenges and environmental concerns related to water quality, downstream flooding, species migration, stakeholder opposition, and transboundary water conflicts between the US and Canada. Despite these drawbacks, running outlets would result in low overspill risks in the next 30 years. In this study we evaluated the efficacy of this outlet-based mitigation strategy under scenarios based on the latest IPCC future climate projections. We used the Coupled Model Intercomparison Project CMIP-5 weather patterns from 17 general circulation models (GCMs) obtained under four representative concentration pathways (RCP) scenarios and downscaled to the DL region. Then, we simulated the changes in lake water levels using the soil and water assessment tool based hydrological model of the watershed. We estimated the probability of future flood risks under those scenarios and compared those with previously estimated overspill risks under the CMIP-3 climate. The CMIP-5 ensemble projected a mean annual temperature of 5.78 °C and mean daily precipitation of 1.42 mm/day; both are higher than the existing CMIP-3 future estimates of 4.98 °C and 1.40 mm/day, respectively. The increased precipitation and higher temperature resulted in a significant increase of DL's overspill risks: 24.4-47.1% without release from outlets and 3.5-14.4% even if the outlets are operated at their combined full 17 m 3 /s capacity. The modeled increases in overspill risks indicate a greater frequency of water releases through the artificial outlets. Future risk mitigation management should include providing a flood warning signal to local resource managers, and tasking policy makers to identify additional solution measures such as land use management in the upper watershed to mitigate DL's flooding.

  15. Validity of secondary retail food outlet data: a systematic review.

    PubMed

    Fleischhacker, Sheila E; Evenson, Kelly R; Sharkey, Joseph; Pitts, Stephanie B Jilcott; Rodriguez, Daniel A

    2013-10-01

    Improving access to healthy foods is a promising strategy to prevent nutrition-related chronic diseases. To characterize retail food environments and identify areas with limited retail access, researchers, government programs, and community advocates have primarily used secondary retail food outlet data sources (e.g., InfoUSA or government food registries). To advance the state of the science on measuring retail food environments, this systematic review examined the evidence for validity reported for secondary retail food outlet data sources for characterizing retail food environments. A literature search was conducted through December 31, 2012, to identify peer-reviewed published literature that compared secondary retail food outlet data sources to primary data sources (i.e., field observations) for accuracy of identifying the type and location of retail food outlets. Data were analyzed in 2013. Nineteen studies met the inclusion criteria. The evidence for validity reported varied by secondary data sources examined, primary data-gathering approaches, retail food outlets examined, and geographic and sociodemographic characteristics. More than half of the studies (53%) did not report evidence for validity by type of food outlet examined and by a particular secondary data source. Researchers should strive to gather primary data but if relying on secondary data sources, InfoUSA and government food registries had higher levels of agreement than reported by other secondary data sources and may provide sufficient accuracy for exploring these associations in large study areas. Published by Elsevier Inc. on behalf of American Journal of Preventive Medicine.

  16. Numerical Modeling of Cavitating Venturi: A Flow Control Element of Propulsion System

    NASA Technical Reports Server (NTRS)

    Majumdar, Alok; Saxon, Jeff (Technical Monitor)

    2002-01-01

    In a propulsion system, the propellant flow and mixture ratio could be controlled either by variable area flow control valves or by passive flow control elements such as cavitating venturies. Cavitating venturies maintain constant propellant flowrate for fixed inlet conditions (pressure and temperature) and wide range of outlet pressures, thereby maintain constant, engine thrust and mixture ratio. The flowrate through the venturi reaches a constant value and becomes independent of outlet pressure when the pressure at throat becomes equal to vapor pressure. In order to develop a numerical model of propulsion system, it is necessary to model cavitating venturies in propellant feed systems. This paper presents a finite volume model of flow network of a cavitating venturi. The venturi was discretized into a number of control volumes and mass, momentum and energy conservation equations in each control volume are simultaneously solved to calculate one-dimensional pressure, density, and flowrate and temperature distribution. The numerical model predicts cavitations at the throat when outlet pressure was gradually reduced. Once cavitation starts, with further reduction of downstream pressure, no change in flowrate is found. The numerical predictions have been compared with test data and empirical equation based on Bernoulli's equation.

  17. Heat Extraction from a Hydraulically Fractured Penny-Shaped Crack in Hot Dry Rock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abe, H.; Mura, T.; Keer, L.M.

    1976-12-01

    Heat extraction from a penny-shaped crack having both inlet and outlet holes is investigated analytically by considering the hydraulic and thermal growth of the crack when fluid is injected at a constant flow rate. The rock mass is assumed to be infinitely extended, homogeneous, and isotropic. The equations for fluid flow are derived and solved to determine the flow pattern in the crack. Temperature distributions in both rock and fluid are also determined. The crack width change due to thermal contraction and the corresponding flow rate increase are discussed. Some numerical calculations of outlet temperature, thermal power extraction, and crackmore » opening displacement due to thermal contraction of rocks are presented for cracks after they attain stationary states for given inlet flow rate and outlet suction pressure. The present paper is a further development of the previous works of Bodvarsson (1969), Gringarten et al. (1975), Lowell (1976), Harlow and Pracht (1972), McFarland (1975), among others, and considers the two-dimensional rather than the one-dimensional crack. Furthermore, the crack radius and width are quantities to be determined rather than given a priori. 11 refs., 1 tab., 5 figs.« less

  18. 40 CFR 63.364 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... complying with § 63.363(b) or (d) through the use of an acid-water scrubber, the owner or operator shall... § 63.364(e) or continuously monitor and record the oxidation temperature at the outlet to the catalyst bed or at the exhaust point from the thermal combustion chamber using the temperature monitor...

  19. 40 CFR 63.364 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... complying with § 63.363(b) or (d) through the use of an acid-water scrubber, the owner or operator shall... § 63.364(e) or continuously monitor and record the oxidation temperature at the outlet to the catalyst bed or at the exhaust point from the thermal combustion chamber using the temperature monitor...

  20. 40 CFR 63.364 - Monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... with § 63.363(b) or (d) through the use of an acid-water scrubber, the owner or operator shall either... § 63.364(e) or continuously monitor and record the oxidation temperature at the outlet to the catalyst bed or at the exhaust point from the thermal combustion chamber using the temperature monitor...

  1. 40 CFR 63.364 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... complying with § 63.363(b) or (d) through the use of an acid-water scrubber, the owner or operator shall... § 63.364(e) or continuously monitor and record the oxidation temperature at the outlet to the catalyst bed or at the exhaust point from the thermal combustion chamber using the temperature monitor...

  2. Association Between Alcohol Use Among College Students and Alcohol Outlet Proximity and Densities.

    PubMed

    Tanumihardjo, Jacob; Shoff, Suzanne M; Koenings, Mallory; Zhang, Zhumin; Lai, HuiChuan J

    2015-08-01

    Alcohol consumption is common on college campuses and is associated with negative consequences. Factors associated with availability of alcohol are not completely understood. To describe how proximity and density of alcohol outlets are associated with any drinking and binge drinking in students at the University of Wisconsin-Madison. Participants were full-time students enrolled in the Young Adults Eating and Active for Health, a multisite, randomized intervention that assessed a variety of health behaviors. Geographic information systems were used to calculate proximity and enumerate alcohol outlet densities. Participants were categorized as "drinkers" or "nondrinkers" based on self-reported alcohol consumption. Binge drinking was categorized as "non-binge drinker," "frequent binge drinker," and "excessive binge drinker." Analysis included regression, t tests, and chi-square tests. RESULTS. Among the 166 participants, 126 (76%) were drinkers. Among drinkers, 80 (63%) were either frequent or excessive binge drinkers. Drinkers lived closer to an alcohol outlet than non-drinkers (0.18 +/- 0.15 vs. 0.61 +/- 1.59 miles, respectively, P=0.005). Within a 1-mile walking radius, there were 47% more establishments for drinkers (153 +/- 47 compared to 104 +/- 55 outlets for nondrinkers, P<0.0001). At distances of 0.10-0.25 and 0.25-0.50 miles, twice as many outlets were available to drinkers (19 +/- 19 and 43 +/- 25, respectively) compared to nondrinkers (7 +/- 11 and 20 +/- 22, respectively), P<0.001. Proximity and density were hot associated with binge drinking frequency. Drinkers lived closer to alcohol outlets and had significantly more outlets available at a distance of up to 1 mile. Municipal and college administrators could consider limiting alcohol license distributions in municipalities with high alcohol consumption.

  3. Occurrence and seasonal variations of per- and polyfluoroalkyl substances (PFASs) including fluorinated alternatives in rivers, drain outlets and the receiving Bohai Sea of China.

    PubMed

    Chen, Hong; Han, Jianbo; Zhang, Can; Cheng, Jiayi; Sun, Ruijun; Wang, Xiaomeng; Han, Gengchen; Yang, Wenchao; He, Xin

    2017-12-01

    A simultaneous sampling campaign was undertaken to study the pollution by 21 per- and polyfluoroalkyl substances (PFASs) in rivers, drain outlets and their receiving Bohai Sea of China. Chlorinated polyfluoroalkyl ether sulfonic acids (Cl-PFESAs) are being used as fluorinated alternatives and they were included in this study. In comparison with other regions and countries, high concentrations of ∑ 21 PFASs in seawater samples from the Bohai Sea, ranging from 5.03 to 41 700 ng/L (median: 64.8 ng/L), were observed. The spatial distribution of PFAS levels in this sea area was in the ranking of Laizhou Bay > Liaodong Bay > Bohai Bay > other sea areas. By comparing the levels and composition profiles of PFASs in the seawater and their sources (rivers and drain outlets), it was concluded that rivers and drain outlets are the primary sources of PFAS contamination to the Bohai Sea. These PFAS levels varied seasonally among the rivers and drain outlets, but statistically significant changes were not observed. Levels of 6:2 and 8:2 Cl-PFESAs in rivers, drain outlets and receiving sea were firstly reported in the present study. Relatively high concentrations of 6:2 Cl-PFESA were found in drain outlets, ranging from below method limits of quantification (MLQ) to 7600 ng/L, but 8:2 Cl-PFAES detection was infrequent and all median concentration below MLQ. Mass discharges to the sea of 6:2 Cl-PFESA from rivers and drain outlets to the sea were estimated to be 37 and 17 kg/y, respectively. Copyright © 2017. Published by Elsevier Ltd.

  4. Patterns of fruit and vegetable availability and price competitiveness across four seasons are different in local food outlets and supermarkets.

    PubMed

    Valpiani, Natalie; Wilde, Parke; Rogers, Beatrice; Stewart, Hayden

    2015-10-01

    To explore the effect of seasonality on fruit and vegetable availability and prices across three outlet types (farmers' markets, roadside stands and conventional supermarkets). Cross-sectional survey of geographically clustered supermarkets, farmers' markets and roadside stands. Enumerators recorded the availability and lowest price for eleven fruits and eighteen vegetables in each season of 2011. Price data were collected at retail outlets located in central and eastern North Carolina. The sample consisted of thirty-three supermarkets, thirty-four farmers' markets and twenty-three roadside stands. Outside the local harvest season, the availability of many fruits and vegetables was substantially lower at farmers' markets and roadside stands compared with supermarkets. Given sufficient availability, some items were significantly cheaper (P<0·05) at direct retail outlets in the peak season (e.g. cantaloupe cost 36·0 % less at roadside stands than supermarkets), while others were significantly more expensive (e.g. carrots cost 137·9 % more at farmers' markets than supermarkets). Although small samples limited statistical power in many non-peak comparisons, these results also showed some differences by item: two-thirds of fruits were cheaper at one or both direct outlets in the spring and autumn, whereas five of eighteen vegetables cost more at direct retail year-round. Commonly consumed fruits and vegetables were more widely available at supermarkets in central and eastern North Carolina than at direct retail outlets, in each season. Contingent on item availability, price competitiveness of the direct retail outlets varied by fruit and vegetable. For many items, the outlets compete on price in more than one season.

  5. Phosphor thermometry system

    DOEpatents

    Beshears, David L.; Sitter, Jr., David N.; Andrews, William H.; Simpson, Marc L.; Abston, Ruth A.; Cates, Michael R.; Allison, Steve W.

    2000-01-01

    An apparatus for measuring the temperature of a moving substrate includes an air gun with a powder inlet port in communication with the outlet port of a powder reservoir, an air inlet port in communication with a pressurized air source, and an outlet nozzle spaced from and directed toward the moving substrate. The air gun is activated by the air pulses to spray controlled amounts of the powdered phosphor onto the moving substrate, where the phosphor assumes the temperature of the moving substrate. A laser produces light pulses, and optics direct the light pulses onto the phosphor on the moving substrate, in response to which the phosphor emits a luminescence with a decay rate indicative of the temperature of the phosphor. A collection lens is disposed to focus the luminescence, and a photodetector detects the luminescence focused by the collection lens and produces an electrical signal that is characteristic of the brightness of the luminescence. A processor analyzes the electrical signal to determine the decay characteristic of the luminescence and to determine the temperature of the phosphor from the decay characteristic.

  6. Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing.

    PubMed

    Schilperoort, Rémy; Hoppe, Holger; de Haan, Cornelis; Langeveld, Jeroen

    2013-01-01

    A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm water in foul sewer systems can be significant, resulting in a number of detrimental effects on the performance of the wastewater system. Efficient removal of storm water inflows into foul sewers requires knowledge of the exact locations of the inflows. This paper presents the use of distributed temperature sensing (DTS) monitoring data to localize illicit storm water inflows into foul sewer systems. Data results from two monitoring campaigns in foul sewer systems in the Netherlands and Germany are presented. For both areas a number of storm water inflow locations can be derived from the data. Storm water inflow can only be detected as long as the temperature of this inflow differs from the in-sewer temperatures prior to the event. Also, the in-sewer propagation of storm and wastewater can be monitored, enabling a detailed view on advection.

  7. VENTED FUEL ELEMENT FOR GAS-COOLED NEUTRONIC REACTORS

    DOEpatents

    Furgerson, W.T.

    1963-12-17

    A hollow, porous-walled fuel element filled with fissionable fuel and provided with an outlet port through its wall is described. In operation in a gas-cooled reactor, the element is connected, through its outlet port, to the vacuum side of a pump that causes a portion of the coolant gas flowing over the exterior surface of the element to be drawn through the porous walls thereof and out through the outlet port. This continuous purging gas flow sweeps away gaseous fission products as they are released by the fissioning fuel. (AEC) A fuel element for a nuclear reactor incorporating a body of metal of melting point lower than the temperature of operation of the reactor and a nuclear fuel in finely divided form dispersed in the body of metal as a settled slurry is presented. (AEC)

  8. High-temperature, high-pressure oxygen metering valve

    NASA Technical Reports Server (NTRS)

    Christianson, Rollin C. (Inventor); Lycou, Peter P. (Inventor); Daniel, James A. (Inventor)

    1993-01-01

    A control valve includes a body defining a central cavity arranged between a fluid inlet and outwardly-diverging first and second fluid outlets respectively disposed in a common transverse plane. A valve member is arranged in the cavity for rotation between first and second operating positions where a transverse fluid passage through the valve member alternatively communicates the fluid inlet with one or the other of the fluid outlets. To minimize fluid turbulence when the valve member is rotated to an alternate operating position, the fluid passage has a convergent entrance for maintaining the passage in permanent communication with the fluid inlet as well as an oblong exit opening with spaced side walls for enabling the exit opening to temporarily span the first and second fluid outlets as the valve member is turned between its respective operating positions.

  9. 40 CFR 1065.695 - Data requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... restriction. (v) Charge air cooler volume. (vi) Charge air cooler outlet temperature, specified engine... following: (i) Drift correction. (ii) Noise correction. (iii) “Dry-to-wet” correction. (iv) NMHC, CH4, and...

  10. 40 CFR 1065.695 - Data requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... restriction. (v) Charge air cooler volume. (vi) Charge air cooler outlet temperature, specified engine... following: (i) Drift correction. (ii) Noise correction. (iii) “Dry-to-wet” correction. (iv) NMHC, CH4, and...

  11. 40 CFR 1065.695 - Data requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... restriction. (v) Charge air cooler volume. (vi) Charge air cooler outlet temperature, specified engine... following: (i) Drift correction. (ii) Noise correction. (iii) “Dry-to-wet” correction. (iv) NMHC, CH4, and...

  12. Assessment of emissions and removal of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) at start-up periods in a hazardous waste incinerator.

    PubMed

    Karademir, Aykan; Korucu, M Kemal

    2013-07-01

    A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3-4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter. This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2-3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.

  13. A Flow-Channel Analysis for the Mars Hopper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    W. Spencer Cooley

    The Mars Hopper is an exploratory vehicle designed to fly on Mars using carbon dioxide from the Martian atmosphere as a rocket propellant. The propellent gasses are thermally heated while traversing a radioisotope ther- mal rocket (RTR) engine’s core. This core is comprised of a radioisotope surrounded by a heat capacitive material interspersed with tubes for the propellant to travel through. These tubes, or flow channels, can be manu- factured in various cross-sectional shapes such as a special four-point star or the traditional circle. Analytical heat transfer and computational fluid dynamics (CFD) anal- yses were performed using flow channels withmore » either a circle or a star cross- sectional shape. The nominal total inlet pressure was specified at 2,805,000 Pa; and the outlet pressure was set to 2,785,000 Pa. The CO2 inlet tem- perature was 300 K; and the channel wall was 1200 K. The steady-state CFD simulations computed the smooth-walled star shape’s outlet temper- ature to be 959 K on the finest mesh. The smooth-walled circle’s outlet temperature was 902 K. A circle with a surface roughness specification at 0.01 mm gave 946 K and at 0.1 mm yielded 989 K. The The effects of a slightly varied inlet pressure were also examined. The analytical calculations were based on the mass flow rates computed in the CFD simulations and provided significantly higher outlet temperature results while displaying the same comparison trends. Research relating to the flow channel heat transfer studies was also done. Mathematical methods to geometrically match the cross-sectional areas of the circle and star, along with a square and equilateral triangle, were derived. A Wolfram Mathematica 8 module was programmed to analyze CFD results using Richardson Extrapolation and calculate the grid convergence index (GCI). A Mathematica notebook, also composed, computes and graphs the bulk mean temperature along a flow channel’s length while the user dynam- ically provides the input variables, allowing their effects on the temperature to be more easily observed.« less

  14. From the front

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, Stephen

    The causes of recent dynamic thinning of Greenland's outlet glaciers have been debated. Realistic simulations suggest that changes at the marine fronts of these glaciers are to blame, implying that dynamic thinning will cease once the glaciers retreat to higher ground. For the last decade, many outlet glaciers in Greenland that terminate in the ocean have accelerated, thinned, and retreated. To explain these dynamic changes, two hypotheses have been discussed. Atmospheric warming has increased surface melting and may also have increased the amount of meltwater reaching the glacier bed, increasing lubrication at the base and hence the rate of glaciermore » sliding. Alternatively, a change in the delicate balance of forces where the glacier fronts meet the ocean could trigger the changes. Faezeh Nick and colleagues5 present ice-sheet modeling experiments that mimic the observations on Helheim glacier, East Greenland, and suggest that the dynamic behaviour of outlet glaciers follows from perturbations at their marine fronts. Greenland's ice sheet loses mass partly through surface melting and partly through fast flowing outlet glaciers that connect the vast plateau of inland ice with the ocean. Earlier ice sheet models have failed to reproduce the dynamic variability exhibited by ice sheets over time. It has therefore not been possible to distinguish with confidence between basal lubrication from surface meltwater and changes at the glaciers' marine fronts as causes for the observed changes on Greenland's outlet glaciers. But this distinction bears directly on future sea-level rise, the raison d'etre of much of modern-day glaciology: If the recent dynamic mass loss Greenland's outlet glaciers is linked to changing atmospheric temperatures, it may continue for as long as temperatures continue to increase. On the other hand, if the source of the dynamic mass loss is a perturbation at the ice-ocean boundary, these glaciers will lose contact with that perturbation after a finite amount of thinning and retreat. Therefore, the first hypothesis implies continued retreat of outlet glaciers into the foreseeable future, while the second does not -- provided the bedrock topography prohibits a connection between the retreating glacier and the ocean. Nick and coauthors test the physical mechanisms implied in each hypotbesis in an innovative ice-flow model, and use that model to try to match a time series of observations from Helheim glacier, one of Greenland's three largest outlet glaciers. Along with many observations, the simulations strongly support the contention that the recent retreat of Greenland's outlet glaciers is the result of changes at their marine fronts.Further, the simulations confirm the earlier hypotheses that bedrock topography largely controlled Helheim glacier's rapid acceleration and retreat in 2004 and 2005, and its deceleration and stabilization in 2006. Finally, the current work implies that if requirements of observational data (high-resolution bed topography) and computational resources (fine computational grid resolution) can be met, improved predictive capability for ice-sheet models is attainable. With respect to the concerns raised by the IPCC, this study signals progress.« less

  15. Numerical modeling and analytical modeling of cryogenic carbon capture in a de-sublimating heat exchanger

    NASA Astrophysics Data System (ADS)

    Yu, Zhitao; Miller, Franklin; Pfotenhauer, John M.

    2017-12-01

    Both a numerical and analytical model of the heat and mass transfer processes in a CO2, N2 mixture gas de-sublimating cross-flow finned duct heat exchanger system is developed to predict the heat transferred from a mixture gas to liquid nitrogen and the de-sublimating rate of CO2 in the mixture gas. The mixture gas outlet temperature, liquid nitrogen outlet temperature, CO2 mole fraction, temperature distribution and de-sublimating rate of CO2 through the whole heat exchanger was computed using both the numerical and analytic model. The numerical model is built using EES [1] (engineering equation solver). According to the simulation, a cross-flow finned duct heat exchanger can be designed and fabricated to validate the models. The performance of the heat exchanger is evaluated as functions of dimensionless variables, such as the ratio of the mass flow rate of liquid nitrogen to the mass flow rate of inlet flue gas.

  16. System Analysis for Decay Heat Removal in Lead-Bismuth-Cooled Natural-Circulation Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakai, Takaaki; Enuma, Yasuhiro; Iwasaki, Takashi

    2004-03-15

    Decay heat removal analyses for lead-bismuth-cooled natural-circulation reactors are described in this paper. A combined multidimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural-circulation reactors. For the preliminary study, transient analysis has been performed for a 300-MW(thermal) lead-bismuth-cooled reactor designed by Argonne National Laboratory. In addition, decay heat removal characteristics of a 400-MW(electric) lead-bismuth-cooled natural-circulation reactor designed by the Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. The primary reactor auxiliary cooling system (PRACS) is prepared for the JNC concept to get sufficient heat removal capacity. During 2000 smore » after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 deg. C because the buoyancy force in a primary circulation path is temporarily reduced. However, the natural circulation is recovered by the PRACS system, and the outlet temperature decreases successfully.« less

  17. Benefits and limitations of animal models in partial bladder outlet obstruction for translational research.

    PubMed

    Kitta, Takeya; Kanno, Yukiko; Chiba, Hiroki; Higuchi, Madoka; Ouchi, Mifuka; Togo, Mio; Moriya, Kimihiko; Shinohara, Nobuo

    2018-01-01

    The functions of the lower urinary tract have been investigated for more than a century. Lower urinary tract symptoms, such as incomplete bladder emptying, weak urine stream, daytime urinary frequency, urgency, urge incontinence and nocturia after partial bladder outlet obstruction, is a frequent cause of benign prostatic hyperplasia in aging men. However, the pathophysiological mechanisms have not been fully elucidated. The use of animal models is absolutely imperative for understanding the pathophysiological processes involved in bladder dysfunction. Surgical induction has been used to study lower urinary tract functions of numerous animal species, such as pig, dog, rabbit, guinea pig, rat and mouse, of both sexes. Several morphological and functional modifications under partial bladder outlet obstruction have not only been observed in the bladder, but also in the central nervous system. Understanding the changes of the lower urinary tract functions induced by partial bladder outlet obstruction would also contribute to appropriate drug development for treating these pathophysiological conditions. In the present review, we discuss techniques for creating partial bladder outlet obstruction, the characteristics of several species, as well as issues of each model, and their translational value. © 2017 The Japanese Urological Association.

  18. Outlet Glacier-Ice Shelf-Ocean Interactions: Is the Tail Wagging the Dog?

    NASA Astrophysics Data System (ADS)

    Parizek, B. R.; Walker, R. T.; Rinehart, S. K.

    2009-12-01

    While the massive interior regions of the Antarctic and Greenland Ice Sheets are presently ``resting quietly", the lower elevations of many outlet glaciers are experiencing dramatic adjustments due to changes in ice dynamics and/or surface mass balance. Oceanic and/or atmospheric forcing in these marginal regions often leads to mass deficits for entire outlet basins. Therefore, coupling the wagging tail of ice-ocean interactions with the vast ice-sheet reservoirs is imperative for accurate assessments of future sea-level rise. To study ice-ocean dynamic processes, we couple an ocean-plume model that simulates ice-shelf basal melting rates based on temperature and salinity profiles combined with plume dynamics associated with the geometry of the ice-shelf cavity (following Jenkins, 1991 and Holland and Jenkins, 1999) with a two-dimensional, isothermal model of outlet glacier-ice shelf flow (as used in Alley et al., 2007; Walker et al., 2008; Parizek et al., in review). Depending on the assigned temperature and salinity profiles, the ocean model can simulate both water-mass end-members: either cold High Salinity Shelf Water (HSSW) or relatively warm Circumpolar Deep Water (CDW), as well as between-member conditions. Notably, the coupled system exhibits sensitivity to the initial conditions. In particular, melting concentrated near the grounding line has the greatest effect in forcing grounding-line retreat. Retreat is further enhanced by a positive feedback between the ocean and ice, as the focused melt near the grounding line leads to an increase in the local slope of the basal ice, thereby enhancing buoyancy-driven plume flow and subsequent melt rates.

  19. The Role of Alcohol Policies in Preventing Intimate Partner Violence: A Review of the Literature

    PubMed Central

    Kearns, Megan C.; Reidy, Dennis E.; Valle, Linda Anne

    2015-01-01

    Objective This article summarizes existing research on the relationship between alcohol policies and intimate partner violence (IPV). Because alcohol represents an important risk factor for IPV, interventions and policies aimed at decreasing problem drinking may also lead to reductions in IPV. Method Electronic databases were searched to identify relevant peer-reviewed journal articles on alcohol policies and IPV, as well as reference sections of appropriate articles. Only policies that have been studied specifically for impact on IPV were included. Results Three alcohol policy areas (outlet density, hours and days of sale, pricing/taxation) had been studied in relation to IPV outcomes. Research on outlet density had the most consistent findings, with most studies indicating that higher densities of alcohol outlets are associated with higher rates of IPV. Fewer studies had been conducted on pricing policies and policies restricting hours/days of sale, with most studies suggesting no impact on IPV rates. Conclusions Higher density of alcohol outlets appears to be associated with greater rates of IPV. However, there is limited evidence suggesting that alcohol pricing policies and restrictions on hours/days of sale are associated with IPV outcomes. Knowledge about the impact of alcohol-related policies on IPV and violence in general is limited by several significant research gaps. Additional research is needed to assess the impact of alcohol policies on IPV and other forms of violence. PMID:25486390

  20. Neighborhood Disparities in Access to Healthy Foods and Their Effects on Environmental Justice

    PubMed Central

    Dave, Jayna

    2012-01-01

    Environmental justice is concerned with an equitable distribution of environmental burdens. These burdens comprise immediate health hazards as well as subtle inequities, such as limited access to healthy foods. We reviewed the literature on neighborhood disparities in access to fast-food outlets and convenience stores. Low-income neighborhoods offered greater access to food sources that promote unhealthy eating. The distribution of fast-food outlets and convenience stores differed by the racial/ethnic characteristics of the neighborhood. Further research is needed to address the limitations of current studies, identify effective policy actions to achieve environmental justice, and evaluate intervention strategies to promote lifelong healthy eating habits, optimum health, and vibrant communities. PMID:22813465

  1. Improvement of fire-tube boilers calculation methods by the numerical modeling of combustion processes and heat transfer in the combustion chamber

    NASA Astrophysics Data System (ADS)

    Komarov, I. I.; Rostova, D. M.; Vegera, A. N.

    2017-11-01

    This paper presents the results of study on determination of degree and nature of influence of operating conditions of burner units and flare geometric parameters on the heat transfer in a combustion chamber of the fire-tube boilers. Change in values of the outlet gas temperature, the radiant and convective specific heat flow rate with appropriate modification of an expansion angle and a flare length was determined using Ansys CFX software package. Difference between values of total heat flow and bulk temperature of gases at the flue tube outlet calculated using the known methods for thermal calculation and defined during the mathematical simulation was determined. Shortcomings of used calculation methods based on the results of a study conducted were identified and areas for their improvement were outlined.

  2. Evaluation and Optimization of a Supercritical Carbon Dioxide Power Conversion Cycle for Nuclear Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwin A. Harvego; Michael G. McKellar

    2011-05-01

    There have been a number of studies involving the use of gases operating in the supercritical mode for power production and process heat applications. Supercritical carbon dioxide (CO2) is particularly attractive because it is capable of achieving relatively high power conversion cycle efficiencies in the temperature range between 550°C and 750°C. Therefore, it has the potential for use with any type of high-temperature nuclear reactor concept, assuming reactor core outlet temperatures of at least 550°C. The particular power cycle investigated in this paper is a supercritical CO2 Recompression Brayton Cycle. The CO2 Recompression Brayton Cycle can be used as eithermore » a direct or indirect power conversion cycle, depending on the reactor type and reactor outlet temperature. The advantage of this cycle when compared to the helium Brayton Cycle is the lower required operating temperature; 550°C versus 850°C. However, the supercritical CO2 Recompression Brayton Cycle requires an operating pressure in the range of 20 MPa, which is considerably higher than the required helium Brayton cycle operating pressure of 8 MPa. This paper presents results of analyses performed using the UniSim process analyses software to evaluate the performance of the supercritical CO2 Brayton Recompression Cycle for different reactor outlet temperatures. The UniSim model assumed a 600 MWt reactor power source, which provides heat to the power cycle at a maximum temperature of between 550°C and 750°C. The UniSim model used realistic component parameters and operating conditions to model the complete power conversion system. CO2 properties were evaluated, and the operating range for the cycle was adjusted to take advantage of the rapidly changing conditions near the critical point. The UniSim model was then optimized to maximize the power cycle thermal efficiency at the different maximum power cycle operating temperatures. The results of the analyses showed that power cycle thermal efficiencies in the range of 40 to 50% can be achieved.« less

  3. New design of a PEFC cathode separator of for water management

    NASA Astrophysics Data System (ADS)

    Sugiura, K.; Takahashi, N.; Kamimura, T.

    2017-11-01

    Generally, polymer electrolyte fuel cells (PEFCs) need humidifiers to prevent the drying of the membrane, but this use of humidifiers creates water management issues, such as the flooding/plugging phenomena and decreased system efficiency because of an increase in the electric energy needed for auxiliary equipment. Although most researchers have developed high-temperature membranes that do not need humidifiers, a lot of time is necessary for the development of these membranes, and these membranes drive up costs. Therefore, we propose a new cathode separator design that can recycle water generated by power generation in the same cell and a stack structure that can redistribute water collected in the cathode outlet manifold to drying cells. Because the new cathode separator has a bypass channel from the gas outlet to the gas inlet to transport excess water, a dry part in the gas inlet is supplied with excess water in the gas outlet through the bypass channel even if the PEFC is operated under dry conditions. Excess water in the PEFC stack can be transported from the cell with excess water to the drying cell through the cathode outlet manifold with a porous wall. Therefore, we confirm the influence of the plugging phenomenon in the cathode gas outlet manifold on the cell performance of each cell in the stack. As a result, the cell performance of the new cathode separator design is better than that of the standard separator under the low humidity conditions. We confirm that the plugging phenomenon in the cathode outlet manifold affects the cell performance of each cell in the stack.

  4. Scale Resistant Heat Exchanger for Low Temperature Geothermal Binary Cycle Power Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, Lance G.

    2014-11-18

    Phase 1 of the investigation of improvements to low temperature geothermal power systems was completed. The improvements considered were reduction of scaling in heat exchangers and a hermetic turbine generator (eliminating seals, seal system, gearbox, and lube oil system). A scaling test system with several experiments was designed and operated at Coso geothermal resource with brine having a high scaling potential. Several methods were investigated at the brine temperature of 235 ºF. One method, circulation of abradable balls through the brine passages, was found to substantially reduce scale deposits. The test heat exchanger was operated with brine outlet temperatures asmore » low as 125 ºF, which enables increased heat input available to power conversion systems. For advanced low temperature cycles, such as the Variable Phase Cycle (VPC) or Kalina Cycle, the lower brine temperature will result in a 20-30% increase in power production from low temperature resources. A preliminary design of an abradable ball system (ABS) was done for the heat exchanger of the 1 megawatt VPC system at Coso resource. The ABS will be installed and demonstrated in Phase 2 of this project, increasing the power production above that possible with the present 175 ºF brine outlet limit. A hermetic turbine generator (TGH) was designed and manufacturing drawings produced. This unit will use the working fluid (R134a) to lubricate the bearings and cool the generator. The 200 kW turbine directly drives the generator, eliminating a gearbox and lube oil system. Elimination of external seals eliminates the potential of leakage of the refrigerant or hydrocarbon working fluids, resulting in environmental improvement. A similar design has been demonstrated by Energent in an ORC waste heat recovery system. The existing VPC power plant at Coso was modified to enable the “piggyback” demonstration of the TGH. The existing heat exchanger, pumps, and condenser will be operated to provide the required process conditions for the TGH demonstration. Operation of the TGH with and without the ABS system will demonstrate an increase in geothermal resource productivity for the VPC from 1 MW/(million lb) of brine to 1.75 MW/(million lb) of brine, a 75% increase.« less

  5. Sample flow switching techniques on microfluidic chips.

    PubMed

    Pan, Yu-Jen; Lin, Jin-Jie; Luo, Win-Jet; Yang, Ruey-Jen

    2006-02-15

    This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.

  6. Fate of hazardous air pollutants in oxygen-fired coal combustion with different flue gas recycling.

    PubMed

    Zhuang, Ye; Pavlish, John H

    2012-04-17

    Experiments were performed to characterize transformation and speciation of hazardous air pollutants (HAPs), including SO(2)/SO(3), NO(x), HCl, particulate matter, mercury, and other trace elements in oxygen-firing bituminous coal with recirculation flue gas (RFG) from 1) an electrostatic precipitator outlet or 2) a wet scrubber outlet. The experimental results showed that oxycombustion with RFG generated a flue gas with less volume and containing HAPs at higher levels, while the actual emissions of HAPs per unit of energy produced were much less than that of air-blown combustion. NO(x) reduction was achieved in oxycombustion because of the elimination of nitrogen and the destruction of NO in the RFG. The elevated SO(2)/SO(3) in flue gas improved sulfur self-retention. SO(3) vapor could reach its dew point in the flue gas with high moisture, which limits the amount of SO(3) vapor in flue gas and possibly induces material corrosion. Most nonvolatile trace elements were less enriched in fly ash in oxycombustion than air-firing because of lower oxycombustion temperatures occurring in the present study. Meanwhile, Hg and Se were found to be enriched on submicrometer fly ash at higher levels in oxy-firing than in air-blown combustion.

  7. Absorption generator for solar-powered air-conditioner

    NASA Technical Reports Server (NTRS)

    Lowen, D. J.; Murray, J. G.

    1977-01-01

    Device passes solar-heated water through coils. Hot lithium Bromide/Water solution leaves through central stand-pipe, and water vapor leaves through refrigerant outlet at top. Matching generation temperature to collector efficiency helps cut costs.

  8. Conical diffuser for fuel cells

    NASA Technical Reports Server (NTRS)

    Craft, D. W.

    1976-01-01

    Diffuser is inserted into inlet manifold, producing smooth transition of flow from pipe diameter to manifold diameter. Expected pressure gradient and resulting cell-to-cell temperature gradient are reduced. Outlet manifold has nozzle insert that reduces exit losses.

  9. Measurement of unsteady airflow velocity at nozzle outlet

    NASA Astrophysics Data System (ADS)

    Pyszko, René; Machů, Mário

    2017-09-01

    The paper deals with a method of measuring and evaluating the cooling air flow velocity at the outlet of the flat nozzle for cooling a rolled steel product. The selected properties of the Prandtl and Pitot sensing tubes were measured and compared. A Pitot tube was used for operational measurements of unsteady dynamic pressure of the air flowing from nozzles to abtain the flow velocity. The article also discusses the effects of air temperature, pressure and relative air humidity on air density, as well as the influence of dynamic pressure filtering on the error of averaged velocity.

  10. Application of cross recurrence plot for identification of temperature fluctuations synchronization in parallel minichannels

    NASA Astrophysics Data System (ADS)

    Grzybowski, H.; Mosdorf, R.

    2016-09-01

    The temperature fluctuations occurring in flow boiling in parallel minichannels with diameter of 1 mm have been experimentally investigated and analysed. The wall temperature was recorded at each minichannel outlet by thermocouple with 0.08 mm diameter probe. The time series where recorded during dynamic two-phase flow instabilities which are accompanied by chaotic temperature fluctuations. Time series were denoised using wavelet decomposition and were analysed using cross recurrence plots (CRP) which enables the study of two time series synchronization.

  11. Modeling of Greenland outlet glaciers response to future climate change

    NASA Astrophysics Data System (ADS)

    Beckmann, J.

    2017-12-01

    Over the past two decades net mass loss from the Greenland ice sheet (GIS) quadrupled, resulting in 25% of the global mean sea level (GMSL) rise. Increased mass loss of the GIS is caused by enhanced surface melting and speedup of the marine-terminating outlet glaciers. This speedup has been related, among other factors, to enhanced submarine melting, which in turn is caused by warming of the surrounding ocean and by increased subglacial, meltwater discharge. Yet, ice-ocean processes are not properly represented in contemporary Greenland Ice Sheet models used to project future changes in the GIS. In this work, we performed numerical experiments with a one-dimensional plume model coupled to a one-dimensional (depth- and width- integrated) ice flow model for several representative outlet glaciers in Greenland. We investigate the dynamic response of the coupled ice-flow plume model to scenarios of future climate change. In particular, we examine the transient response of the outlet glaciers to projected changes in surface melting, ocean temperature and subglacial discharge. With our modeling approach we quantify the amount of the surface and submarine melting and the resulting retreat and mass loss for each individual glacier for the next 100 years.

  12. A new laboratory-scale experimental facility for detailed aerothermal characterizations of volumetric absorbers

    NASA Astrophysics Data System (ADS)

    Gomez-Garcia, Fabrisio; Santiago, Sergio; Luque, Salvador; Romero, Manuel; Gonzalez-Aguilar, Jose

    2016-05-01

    This paper describes a new modular laboratory-scale experimental facility that was designed to conduct detailed aerothermal characterizations of volumetric absorbers for use in concentrating solar power plants. Absorbers are generally considered to be the element with the highest potential for efficiency gains in solar thermal energy systems. The configu-ration of volumetric absorbers enables concentrated solar radiation to penetrate deep into their solid structure, where it is progressively absorbed, prior to being transferred by convection to a working fluid flowing through the structure. Current design trends towards higher absorber outlet temperatures have led to the use of complex intricate geometries in novel ceramic and metallic elements to maximize the temperature deep inside the structure (thus reducing thermal emission losses at the front surface and increasing efficiency). Although numerical models simulate the conjugate heat transfer mechanisms along volumetric absorbers, they lack, in many cases, the accuracy that is required for precise aerothermal validations. The present work aims to aid this objective by the design, development, commissioning and operation of a new experimental facility which consists of a 7 kWe (1.2 kWth) high flux solar simulator, a radiation homogenizer, inlet and outlet collector modules and a working section that can accommodate volumetric absorbers up to 80 mm × 80 mm in cross-sectional area. Experimental measurements conducted in the facility include absorber solid temperature distributions along its depth, inlet and outlet air temperatures, air mass flow rate and pressure drop, incident radiative heat flux, and overall thermal efficiency. In addition, two windows allow for the direct visualization of the front and rear absorber surfaces, thus enabling full-coverage surface temperature measurements by thermal imaging cameras. This paper presents the results from the aerothermal characterization of a siliconized silicon carbide monolithic honeycomb, conducted at realistic conditions of incident radiative power per unit mass flow rate in order to validate its operation.

  13. 49 CFR 179.400-17 - Inner tank piping.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400... lading temperature. The outlets of all vapor phase and liquid phase lines must be located so that...

  14. Evaporation for Lithium Bromide Aqueous Solution in a Falling Film Heater under Reduced Pressures

    NASA Astrophysics Data System (ADS)

    Matsuda, Akira; Ide, Tetsuo; Yukino, Keiji

    Experiments on evaporation for water and lithium bromide (LiBr) aqueous solution were made in a externally heated wetted-wall column under reduced pressures. For water, evaporation rate increased slightly as feed rate decreased. The heat transfer coefficients of falling film agreed with those for filmwise condensation. For LiBr solution, evaporation rate decreased and outlet temperature of LiBr solution increased as feed rate decreased. The equations of continuity, diffusion and energy which assume that only water moves to the surface and LiBr doesn't move through falling film of LiBr solution were solved numerically. Calculated values of evaporation rate and outlet temperature of solution agreed with experimental results. The results of this work were compared with pool boiling data reported previously, and it was shown that falling film heater is superior to pool boiling heater concerning heat transfer.

  15. Theoretical impacts of a range of major tobacco retail outlet reduction interventions: modelling results in a country with a smoke-free nation goal.

    PubMed

    Pearson, Amber L; van der Deen, Frederieke S; Wilson, Nick; Cobiac, Linda; Blakely, Tony

    2015-03-01

    To inform endgame strategies in tobacco control, this study aimed to estimate the impact of interventions that markedly reduced availability of tobacco retail outlets. The setting was New Zealand, a developed nation where the government has a smoke-free nation goal in 2025. Various legally mandated reductions in outlets that were phased in over 10 years were modelled. Geographic analyses using the road network were used to estimate the distance and time travelled from centres of small areas to the reduced number of tobacco outlets, and from there to calculate increased travel costs for each intervention. Age-specific price elasticities of demand were used to estimate future smoking prevalence. With a law that required a 95% reduction in outlets, the cost of a pack of 20 cigarettes (including travel costs) increased by 20% in rural areas and 10% elsewhere and yielded a smoking prevalence of 9.6% by 2025 (compared with 9.9% with no intervention). The intervention that permitted tobacco sales at only 50% of liquor stores resulted in the largest cost increase (∼$60/pack in rural areas) and the lowest prevalence (9.1%) by 2025. Elimination of outlets within 2 km of schools produced a smoking prevalence of 9.3%. This modelling merges geographic, economic and epidemiological methodologies in a novel way, but the results should be interpreted cautiously and further research is desirable. Nevertheless, the results still suggest that tobacco outlet reduction interventions could modestly contribute to an endgame goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Knowledge and Adherence to the National Guidelines for Malaria Diagnosis in Pregnancy among Health-Care Providers and Drug-Outlet Dispensers in Rural Western Kenya.

    PubMed

    Riley, Christina; Dellicour, Stephanie; Ouma, Peter; Kioko, Urbanus; Omar, Ahmeddin; Kariuki, Simon; Ng'ang'a, Zipporah; Desai, Meghna; Buff, Ann M; Gutman, Julie R

    2018-05-01

    Prompt diagnosis and effective treatment of acute malaria in pregnancy (MiP) is important for the mother and fetus; data on health-care provider adherence to diagnostic guidelines in pregnancy are limited. From September to November 2013, a cross-sectional survey was conducted in 51 health facilities and 39 drug outlets in Western Kenya. Provider knowledge of national diagnostic guidelines for uncomplicated MiP were assessed using standardized questionnaires. The use of parasitologic testing was assessed in health facilities via exit interviews with febrile women of childbearing age and in drug outlets via simulated-client scenarios, posing as pregnant women or their spouses. Overall, 93% of providers tested for malaria or accurately described signs and symptoms consistent with clinical malaria. Malaria was parasitologically confirmed in 77% of all patients presenting with febrile illness at health facilities and 5% of simulated clients at drug outlets. Parasitological testing was available in 80% of health facilities; 92% of patients evaluated at these facilities were tested. Only 23% of drug outlets had malaria rapid diagnostic tests (RDTs); at these outlets, RDTs were offered in 17% of client simulations. No differences were observed in testing rates by pregnancy trimester. The study highlights gaps among health providers in diagnostic knowledge and practice related to MiP, and the lack of malaria diagnostic capacity, particularly in drug outlets. The most important factor associated with malaria testing of pregnant women was the availability of diagnostics at the point of service. Interventions that increase the availability of malaria diagnostic services might improve malaria case management in pregnant women.

  17. Survival of Campylobacter jejuni and Campylobacter coli in retail broiler meat stored at -20, 4 and 12C, and development of predictive models of survival based on temperature and time

    USDA-ARS?s Scientific Manuscript database

    Retail broiler meat undergoes variable freezing and refrigeration temperatures during storage, transportation, display in retail outlets and in consumers’ refrigerators. Due to the relatively high prevalence of Campylobacter found in retail broilers and the low infective dose required to cause human...

  18. Study and development of a cryogenic heat exchanger for life support systems

    NASA Technical Reports Server (NTRS)

    Soliman, M. M.

    1973-01-01

    A prototype cryogenic heat exchanger for removal of waste heat from a spacecraft environmental control life support system was developed. The heat exchanger uses the heat sink capabilities of the cryogenic propellants and, hence, can operate over all mission phases from prelaunch to orbit, to post landing, with quiescent periods during orbit. A survey of candidate warm fluids resulted in the selection of E-2, a fluorocarbon compound, because of its low freezing point and high boiling point. The final design and testing of the heat exchanger was carried out, however, using Freon-21, which is similar to E-2 except for its low boiling point. This change was motivated by the desire for cost effectiveness of the experimental program. The transient performance of the heat exchanger was demonstrated by an analog simulation of the heat sink system. Under the realistic transient heat load conditions (20 sec ramp from minimum to maximum Freon-21 inlet temperature), the control system was able to maintain the warm fluid outlet temperature within + or - 3 F. For a 20-sec ramp from 0 F to -400 F in the hydrogen inlet temperature, at maximum heat load, the warm fluid outlet temperature was maintained within + or - 7 F.

  19. [Thermal energy utilization analysis and energy conservation measures of fluidized bed dryer].

    PubMed

    Xing, Liming; Zhao, Zhengsheng

    2012-07-01

    To propose measures for enhancing thermal energy utilization by analyzing drying process and operation principle of fluidized bed dryers,in order to guide optimization and upgrade of fluidized bed drying equipment. Through a systematic analysis on drying process and operation principle of fluidized beds,the energy conservation law was adopted to calculate thermal energy of dryers. The thermal energy of fluidized bed dryers is mainly used to make up for thermal consumption of water evaporation (Qw), hot air from outlet equipment (Qe), thermal consumption for heating and drying wet materials (Qm) and heat dissipation to surroundings through hot air pipelines and cyclone separators. Effective measures and major approaches to enhance thermal energy utilization of fluidized bed dryers were to reduce exhaust gas out by the loss of heat Qe, recycle dryer export air quantity of heat, preserve heat for dry towers, hot air pipes and cyclone separators, dehumidify clean air in inlets and reasonably control drying time and air temperature. Such technical parameters such air supply rate, air inlet temperature and humidity, material temperature and outlet temperature and humidity are set and controlled to effectively save energy during the drying process and reduce the production cost.

  20. Improving shop floor compliance with age restrictions for alcohol sales: effectiveness of a feedback letter intervention.

    PubMed

    Van Hoof, Joris J; Gosselt, Jordy F; Baas, Niels; De Jong, Menno D T

    2012-10-01

    In this study, we investigated the effects and handling of an intervention to increase compliance with age limits regarding alcohol sales. The intervention tested in this field experiment was a feedback letter sent to alcohol outlets about their individual compliance results based on a mystery shopping study. We measured compliance in 146 alcohol outlets (cafeterias, supermarkets, bars, liquor stores and youth centres) in one region in the Netherlands with 15-year-old mystery shoppers. About half (n=72) of the outlets received the intervention letter (the experimental group). After this intervention, we measured compliance again (n=138). Then we sent the same letter to the control group and interviewed all the outlets regarding their handling of the intervention (n=106). After the experimental group received the letter, compliance increased significantly (from 18.1% to 32.4%). In the control group, compliance did not change. Of the outlets interviewed, 81% stated that they had received the letter, and the action most commonly taken was to bring the letter to the attention of their staff. Positive feedback letters are more often copied and shared integrally with personnel, compared with negative letters. Compliance with respect to underage alcohol sales can be improved, although compliance levels remain low in the Netherlands.

  1. Estimating tobacco consumption in remote Aboriginal communities using retail sales data: some challenges and opportunities.

    PubMed

    MacLaren, David; Redman-MacLaren, Michelle; Clough, Alan

    2010-07-01

    To describe and discuss challenges and opportunities encountered when estimating tobacco consumption in six remote Aboriginal communities using tobacco sales data from retail outlets. We consider tobacco sales data collected from retail outlets selling tobacco to six Aboriginal communities in two similar but separate studies. Despite challenges--including: not all outlets provided data; data not uniform across outlets (sales and invoice data); change in format of data; personnel change or management restructures; and anomalies in data and changes in community populations--tobacco consumption was estimated and returned through project newsletters and community feedback sessions. Amounts of tobacco sold were returned using graphs in newsletters and pictures of items common to the community in community feedback sessions. Despite inherent limitations of estimating tobacco consumption using tobacco sales data, returning the amount of tobacco sold to communities provided an opportunity to discuss tobacco consumption and provide a focal point for individual and community action. Using this method, however, may require large and sustained changes be observed over time to evaluate whether initiatives to reduce tobacco consumption have been effective. Estimating tobacco consumption in remote Aboriginal communities using tobacco sales data from retail outlets requires careful consideration of many logistical, social, cultural and geographic challenges.

  2. CFD Modelling Applied to the Co-Combustion of Paper Sludge and Coal in a 130 t/h CFB Boiler

    NASA Astrophysics Data System (ADS)

    Yu, Z. S.; Ma, X. Q.; Lai, Z. Y.; Xiao, H. M.

    Three-dimensional mathematical model has been developed as a tool for co-combustion of paper sludge and coal in a 130 tJh Circulating Fluidized Bed (CFB) boiler. Mathematical methods had been used based on a commercial software FLUENT for combustion. The predicted results of CFB furnace show that the co-combustion of paper sludge/coal is initially intensively at the bottom of bed; the temperature reaches its maximum in the dense-phase zone, around l400K. It indicates that paper sludge spout into furnace from the recycle inlet can increase the furnace maximum temperature (l396.3K), area-weighted average temperature (l109.6K) and the furnace gas outlet area-weighted average temperature(996.8K).The mathematical modeling also predicts that 15 mass% paper sludge co-combustion is the highest temperature at the flue gas outlet, it is 1000.8K. Moreover, it is proved that mathematical models can serve as a tool for detailed analysis of co-combustion of paper sludge and coal processes in a circulating fluidized bed furnace when in view of its convenience. The results gained from numerical simulation show that paper sludge enter into furnace from the recycle inlet excelled than mixing with coal and at the underside of phase interface.

  3. Obesity and the community food environment: a systematic review.

    PubMed

    Holsten, Joanna E

    2009-03-01

    To examine the relationship between obesity and the community and/or consumer food environment. A comprehensive literature search of multiple databases was conducted and seven studies were identified for review. Studies were selected if they measured BMI and environmental variables related to food outlets. Environmental variables included the geographic arrangement of food stores or restaurants in communities and consumer conditions such as food price and availability within each outlet. The study designs, methods, limitations and results related to obesity and the food environment were reviewed, and implications for future research were synthesized. The reviewed studies used cross-sectional designs to examine the community food environment defined as the number per capita, proximity or density of food outlets. Most studies indirectly identified food outlets through large databases. The studies varied substantially in sample populations, outcome variables, units of measurement and data analysis. Two studies did not find any significant association between obesity rates and community food environment variables. Five studies found significant results. Many of the studies were subject to limitations that may have mitigated the validity of the results. Research examining obesity and the community or consumer food environment is at an early stage. The most pertinent gaps include primary data at the individual level, direct measures of the environment, studies examining the consumer environment and study designs involving a time sequence. Future research should directly measure multiple levels of the food environment and key confounders at the individual level.

  4. Apparatus and method for selectively channeling a fluid

    DOEpatents

    Rightley, Michael Joseph [Albuquerque, NM

    2008-01-01

    An apparatus for selectively channeling a high temperature fluid without chemically reacting with the fluid. The apparatus includes an inlet and a membrane positioned adjacent to the inlet, each composed of a chemically inert material. The membrane is formed by compressive preloading techniques. The apparatus further includes a seat disposed on the inlet adjacent to the membrane. The seat is composed of a heat resistant and chemically inert material. Operation of the apparatus requires that the temperature of the fluid remains below the chemical characteristic melting point of the seat. The apparatus further includes an actuator coupled to the membrane for rendering the membrane in an open and a closed position with respect to the seat. Specifically, the actuator supplies a load in the normal direction to the membrane to selectively engage the membrane in a plurality of predetermined configurations. Operatively, the apparatus receives the fluid at the inlet. The fluid is received at a high temperature and is directed from the inlet to the membrane. In the closed position, the actuator engages the membrane to prevent the fluid from flowing from the inlet between the membrane and the seat. Alternatively, in the open position, the actuator engages the membrane to permit fluid flow from the inlet between the membrane and the seat to at least one outlet provided by the apparatus. In one exemplary embodiment, the fluid may be discharged from the at least one outlet to a sensor in fluid communication with the at least one outlet. Accordingly, the sensor may measure the fluid channeled through the heat resistant and chemically inert environment provided by the apparatus.

  5. Effect of temperature on the accumulation of marine biogenic gels in the surface microlayer near the outlet of nuclear power plants and adjacent areas in the Daya Bay, China.

    PubMed

    Yue, Wei-Zhong; Sun, Cui-Ci; Shi, Ping; Engel, Anja; Wang, You-Shao; He, Wei-Hong

    2018-01-01

    The surface microlayer (SML) in marine systems is often characterized by an enrichment of biogenic, gel-like particles, such as the polysaccharide-containing transparent exopolymer particles (TEP) and the protein-containing Coomassie stainable particles (CSP). This study investigated the distribution of TEP and CSP, in the SML and underlying water, as well as their bio-physical controlling factors in Daya Bay, an area impacted by warm discharge from two Nuclear power plants (Npp's) and aquaculture during a research cruise in July 2014. The SML had higher proportions of cyanobacteria and of pico-size Chl a contrast to the underlayer water, particularly at the nearest outlet station characterized by higher temperature. Diatoms, dinoflagellates and chlorophyll a were depleted in the SML. Both CSP and TEP abundance and total area were enriched in the SML relative to the underlying water, with enrichment factors (EFs) of 1.5-3.4 for CSP numbers and 1.32-3.2 for TEP numbers. Although TEP and CSP showed highest concentration in the region where high productivity and high nutrient concertation were observed, EFs of gels and of dissolved organic carbon (DOC) and dissolved acidic polysaccharide (> 1 kDa), exhibited higher values near the outlet of the Npp's than in the adjacent waters. The positive relation between EF's of gels and temperature and the enrichment of cyanobacteria in the SML may be indicative of future conditions in a warmer ocean, suggesting potential effects on adjusting phytoplankton community, biogenic element cycling and air-sea exchange processes.

  6. Feasibility study of automatic control of crew comfort in the shuttle Extravehicular Mobility Unit. [liquid cooled garment regulator

    NASA Technical Reports Server (NTRS)

    Cook, D. W.

    1977-01-01

    Computer simulation is used to demonstrate that crewman comfort can be assured by using automatic control of the inlet temperature of the coolant into the liquid cooled garment when input to the controller consists of measurements of the garment inlet temperature and the garment outlet temperature difference. Subsequent tests using a facsimile of the control logic developed in the computer program confirmed the feasibility of such a design scheme.

  7. 30 CFR 7.97 - Application requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sensors, flame arresters, exhaust conditioner, emergency intake air shutoff device, automatic fuel shutoff...-cooled components, coolant lines, radiator, surge tank, temperature sensors, and orifices; arrows... internal parts, exhaust inlet and outlet, sensors, and the exhaust gas path through the exhaust conditioner...

  8. 30 CFR 7.97 - Application requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sensors, flame arresters, exhaust conditioner, emergency intake air shutoff device, automatic fuel shutoff...-cooled components, coolant lines, radiator, surge tank, temperature sensors, and orifices; arrows... internal parts, exhaust inlet and outlet, sensors, and the exhaust gas path through the exhaust conditioner...

  9. 30 CFR 7.97 - Application requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sensors, flame arresters, exhaust conditioner, emergency intake air shutoff device, automatic fuel shutoff...-cooled components, coolant lines, radiator, surge tank, temperature sensors, and orifices; arrows... internal parts, exhaust inlet and outlet, sensors, and the exhaust gas path through the exhaust conditioner...

  10. 7 CFR 929.104 - Outlets for excess cranberries.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE CRANBERRIES... development of foreign and domestic markets, including, but not limited to dehydration, radiation, freeze...

  11. Associations between access to alcohol outlets and alcohol intake and depressive symptoms in women from socioeconomically disadvantaged neighbourhoods in Australia.

    PubMed

    Lamb, Karen E; Thornton, Lukar E; Teychenne, Megan; Milte, Catherine; Cerin, Ester; Ball, Kylie

    2017-01-17

    This study examined associations between alcohol outlet access and alcohol intake, depressive symptoms score and risk of depression among women residing in disadvantaged neighbourhoods in Victoria, Australia. Data on depressive symptoms, alcohol intake and socio-demographic characteristics were obtained from a sample of 995 adult women from Victoria, Australia who were surveyed as part of the Resilience in Eating and Activity Despite Inequality (READI) study. The location of all licensed alcohol outlets in Victoria was obtained from the Victorian Commission for Gambling and Liquor Regulation. Participant and alcohol outlet addresses were geocoded to calculate individual alcohol outlet access, defined as the number of outlets (all and by sub-type) within 0.4 km and 3 km of participants' homes. Separate regression models with clustered standard errors were fitted to examine associations between access and alcohol intake according to national recommended limits for short- and long-term harm, frequency of consumption above long-term harm guidelines, depressive symptoms score and risk of depression. Odds of consumption within short-term harm guidelines (≤4 drinks on any day) decreased with increasing access within 3 km, irrespective of outlet type. Typically, there was no evidence to support associations between access and consumption above long-term harm guidelines (>2 drinks on any day) unless considering frequency of consumption at this level where results showed decreased odds of 'don't drink' versus frequently drinking above long-term harm guidelines (i.e., >2 drinks at least once per week) with increasing access at either distance. Although there was no evidence of an association between any of the alcohol outlet access measures and depressive symptoms score, odds of being at risk of depression decreased with increasing access within 3 km. This study found some evidence to support an association between increasing alcohol outlet densities of all types and harmful levels of alcohol consumption, and the association appears to be dependent on the distance threshold considered, among women residing in socioeconomically disadvantaged neighbourhoods within Victoria, Australia. However, higher numbers of alcohol outlets appear to be associated with a slightly lower risk of depression, with further research needed to identify the direction and mechanisms underlying this unintuitive association.

  12. A cross sectional study investigating the association between exposure to food outlets and childhood obesity in Leeds, UK.

    PubMed

    Griffiths, Claire; Frearson, Anna; Taylor, Adam; Radley, Duncan; Cooke, Carlton

    2014-12-06

    Current UK policy in relation to the influence of the 'food environment' on childhood obesity appears to be driven largely on assumptions or speculations because empirical evidence is lacking and findings from studies are inconsistent. The aim of this study was to investigate the number of food outlets and the proximity of food outlets in the same sample of children, without solely focusing on fast food. Cross sectional study over 3 years (n = 13,291 data aggregated). Body mass index (BMI) was calculated for each participant, overweight and obesity were defined as having a BMI >85(th) (sBMI 1.04) and 95(th) (sBMI 1.64) percentiles respectively (UK90 growth charts). Home and school neighbourhoods were defined as circular buffers with a 2 km Euclidean radius, centred on these locations. Commuting routes were calculated using the shortest straight line distance, with a 2 km buffer to capture varying routes. Data on food outlet locations was sourced from Leeds City Council covering the study area and mapped against postcode. Food outlets were categorised into three groups, supermarkets, takeaway and retail. Proximity to the nearest food outlet in the home and school environmental domain was also investigated. Age, gender, ethnicity and deprivation (IDACI) were included as covariates in all models. There is no evidence of an association between the number of food outlets and childhood obesity in any of these environments; Home Q4 vs. Q1 OR = 1.11 (95% CI = 0.95-1.30); School Q4 vs. Q1 OR = 1.00 (95% CI 0.87 - 1.16); commute Q4 vs. Q1 OR = 0.1.00 (95% CI 0.83 - 1.20). Similarly there is no evidence of an association between the proximity to the nearest food outlet and childhood obesity in the home (OR = 0.77 [95% CI = 0.61 - 0.98]) or the school (OR = 1.01 [95% CI 0.84 - 1.23]) environment. This study provides little support for the notion that exposure to food outlets in the home, school and commuting neighbourhoods increase the risk of obesity in children. It seems that the evidence is not well placed to support Governmental interventions/recommendations currently being proposed and that policy makers should approach policies designed to limit food outlets with caution.

  13. Benthic nutrient fluxes and sediment oxygen consumption in a full-scale facultative pond in Patagonia, Argentina.

    PubMed

    Faleschini, M; Esteves, J L

    2013-01-01

    The study of benthic metabolism is an interesting tool to understand the process that occurs in bottom water at wastewater stabilization ponds. Here, rates of benthic oxygen consumption and nutrient exchange across the water-sludge interface were measured in situ using a benthic chamber. The research was carried out during autumn, winter, and summer at a municipal facultative stabilization pond working in a temperate region (Puerto Madryn city, Argentina). Both a site near the raw wastewater inlet (Inlet station) and a site near the outlet (Outlet station) were sampled. Important seasonal and spatial patterns were identified as being related to benthic fluxes. Ammonium release ranged from undetectable (autumn/summer - Inlet station) to +30.7 kg-NH4(+) ha(-1) d(-1) (autumn - Outlet station), denitrification ranged from undetectable (winter - in both sites) to -4.0 kg-NO3(-) ha(-1) d(-1) (autumn - Outlet station), and oxygen consumption ranged from 0.07 kg-O2ha(-1) d(-1) (autumn/summer - Outlet station) to 0.84 kg-O2ha(-1) d(-1) (autumn - Inlet station). During the warmer months, the mineralization of organic matter from the bottom pond acts as a source of nutrients, which seem to support the important development of phytoplankton and nitrification activity recorded in the surface water. Bottom processes could be related to the advanced degree and efficiency of the treatment, the temperature, and probably the strong and frequent wind present in the region.

  14. Preliminary design of high temperature ultrasonic transducers for liquid sodium environments

    NASA Astrophysics Data System (ADS)

    Prowant, M. S.; Dib, G.; Qiao, H.; Good, M. S.; Larche, M. R.; Sexton, S. S.; Ramuhalli, P.

    2018-04-01

    Advanced reactor concepts include fast reactors (including sodium-cooled fast reactors), gas-cooled reactors, and molten-salt reactors. Common to these concepts is a higher operating temperature (when compared to light-water-cooled reactors), and the proposed use of new alloys with which there is limited operational experience. Concerns about new degradation mechanisms, such as high-temperature creep and creep fatigue, that are not encountered in the light-water fleet and longer operating cycles between refueling intervals indicate the need for condition monitoring technology. Specific needs in this context include periodic in-service inspection technology for the detection and sizing of cracking, as well as technologies for continuous monitoring of components using in situ probes. This paper will discuss research on the development and evaluation of high temperature (>550°C; >1022°F) ultrasonic probes that can be used for continuous monitoring of components. The focus of this work is on probes that are compatible with a liquid sodium-cooled reactor environment, where the core outlet temperatures can reach 550°C (1022°F). Modeling to assess sensitivity of various sensor configurations and experimental evaluation have pointed to a preferred design and concept of operations for these probes. This paper will describe these studies and ongoing work to fabricate and fully evaluate survivability and sensor performance over extended periods at operational temperatures.

  15. High Temperature Falling Particle Receiver (2012 - 2016) - Final DOE Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Clifford K.

    The objective of this work was to advance falling particle receiver designs for concentrating solar power applications that will enable higher temperatures (>700 °C) and greater power-cycle efficiencies (≥50% thermal-to-electric). Modeling, design, and testing of components in Phases 1 and 2 led to the successful on-sun demonstration in Phase 3 of the world’s first continuously recirculating high-temperature 1 MW t falling particle receiver that achieved >700 °C particle outlet temperatures at mass flow rates ranging from 1 – 7 kg/s.

  16. Simple Electrolyzer Model Development for High-Temperature Electrolysis System Analysis Using Solid Oxide Electrolysis Cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    JaeHwa Koh; DuckJoo Yoon; Chang H. Oh

    2010-07-01

    An electrolyzer model for the analysis of a hydrogen-production system using a solid oxide electrolysis cell (SOEC) has been developed, and the effects for principal parameters have been estimated by sensitivity studies based on the developed model. The main parameters considered are current density, area specific resistance, temperature, pressure, and molar fraction and flow rates in the inlet and outlet. Finally, a simple model for a high-temperature hydrogen-production system using the solid oxide electrolysis cell integrated with very high temperature reactors is estimated.

  17. Thermal performances of vertical hybrid PV/T air collector

    NASA Astrophysics Data System (ADS)

    Tabet, I.; Touafek, K.; Bellel, N.; Khelifa, A.

    2016-11-01

    In this work, numerical analyses and the experimental validation of the thermal behavior of a vertical photovoltaic thermal air collector are investigated. The thermal model is developed using the energy balance equations of the PV/T air collector. Experimental tests are conducted to validate our mathematical model. The tests are performed in the southern Algerian region (Ghardaïa) under clear sky conditions. The prototype of the PV/T air collector is vertically erected and south oriented. The absorber upper plate temperature, glass cover temperature, air temperature in the inlet and outlet of the collector, ambient temperature, wind speed, and solar radiation are measured. The efficiency of the collector increases with increase in mass flow of air, but the increase in mass flow of air reduces the temperature of the system. The increase in efficiency of the PV/T air collector is due to the increase in the number of fins added. In the experiments, the air temperature difference between the inlet and the outlet of the PV/T air collector reaches 10 ° C on November 21, 2014, the interval time is between 10:00 and 14:00, and the temperature of the upper plate reaches 45 ° C at noon. The mathematical model describing the dynamic behavior of the typical PV/T air collector is evaluated by calculating the root mean square error and mean absolute percentage error. A good agreement between the experiment and the simulation results is obtained.

  18. Routine postoperative upper gastrointestinal series after Roux-en-Y gastric bypass: determination of whether it is necessary.

    PubMed

    Kolakowski, Stephen; Kirkland, Matt L; Schuricht, Alan L

    2007-10-01

    To evaluate the clinical utility of the routine use of postoperative barium swallow to diagnose postoperative complications in patients undergoing open or laparoscopic Roux-en-Y gastric bypass. A total of 417 consecutive patients undergoing Roux-en-Y gastric bypass at our institution between January 1, 2001, and December 31, 2002, were included. We performed 341 open procedures and 76 laparoscopic gastric bypasses. All patients received a limited postoperative fluoroscopic upper gastrointestinal series, except for the patients who exceeded the weight limitation of the radiologic equipment. Radiologic findings of anastomotic complications were anastomotic leak, delayed gastric emptying, gastric outlet obstruction, and gastrogastric fistula. We evaluated clinical signs and symptoms to obtain a list of criteria suggesting these complications. Patients were stratified into 2 groups: those with and those without radiographic anastomotic complications. Clinical and radiologic criteria were compared using univariate and multivariate logistic regression analysis. We noted 42 radiologic abnormalities during a routine postoperative barium swallow evaluation. Among our 417 patients, we documented 12 leaks (2.9%), 19 cases of delayed gastric emptying (4.6%), 4 gastric outlet obstructions (1.0%), and 7 gastrogastric fistulas (1.7%). The combination of fever, tachycardia, and tachypnea was the most specific indicator of a leak, at 0.99 (95% confidence limit, 0.99, 1.01). Nausea with vomiting was the most predictive indicator of delayed gastric emptying and gastric outlet obstruction, with a specificity of 0.99 (95% confidence limit, 0.98, 0.99) and 0.97 (95% confidence limit, 0.96, 0.99), respectively. Postoperative complications after Roux-en-Y gastric bypass surgery are predictable based on the patient's symptoms. The use of routine postoperative fluoroscopic upper gastrointestinal series is unnecessary in asymptomatic patients.

  19. Passage probabilities of juvenile Chinook salmon through the powerhouse and regulating outlet at Cougar Dam, Oregon, 2011

    USGS Publications Warehouse

    Beeman, John W.; Hansen, Amy C.; Evans, Scott D.; Haner, Philip V.; Hansel, Hal C.; Smith, Collin D.

    2012-01-01

    Cougar Dam near Springfield, Oregon, is one of several federally owned and operated flood-control projects within the Willamette Valley of western Oregon that were determined by the National Oceanic and Atmospheric Administration’s National Marine Fisheries Service in 2008 to impact the long-term viability of several salmonid stocks. In response to this ruling, the U.S. Army Corps of Engineers is looking for means to reduce impacts to salmonids, including improving downstream passage of juvenile salmonids at Cougar Dam. This study of juvenile Chinook salmon (Oncorhynchus tshawytscha) passage at Cougar Dam was conducted to inform decisions about potential improvements for downstream fish passage. The primary objective of the study was to estimate route-specific passage probabilities of yearling Chinook salmon at Cougar Dam. The study was conducted using fish from a nearby hatchery surgically implanted with radio transmitters and passive integrated transponder (PIT) tags and released near the entrance of a temperature control tower through which all water going through the dam must pass. Water passing through the temperature control tower may be routed through a penstock to a powerhouse with two Francis turbines, or to a spillway-like structure called the regulating outlet. Secondary objectives of the study were to estimate the probability that fish enter a bypass at a non-federal facility downstream, and to estimate dam-passage and in-river fish survival. Dam operating conditions during the study included an average forebay elevation of 1,580 feet (National Geodetic Vertical Datum of 1929) and an average of 48.2 percent of the total dam discharge of 1,106 cubic feet per second passing through a regulating outlet opening of 1.25 feet. Dam passage probability was greatest at night (0.8741 standard error [SE] 0.0265) and primarily through the regulating outlet (0.8896 SE 0.0617 day; 0.9417 SE 0.0175 night). The joint probability of entering the bypass at Leaburg Dam and being detected at the PIT system within the bypass was 0.0755 (SE 0.0363), but some fish were known to pass the PIT system undetected, indicating that the true probability of entering the bypass was underestimated. The estimated survival of fish passing through the temperature control tower, through the dam, and to a site at a bridge over the South Fork of the McKenzie River 3.9 kilometers downstream was 0.3680 (SE 0.1322) for fish passing through the powerhouse, and 0.4247 (SE 0.0440) for fish passing through the regulating outlet. The estimated in-river survival through the 37.3 kilometers from the bridge to a site at Leaburg Hatchery on the McKenzie River was 0.5857 (SE 0.2227) for fish that had passed through the powerhouse, and 0.4537 (SE 0.0551) for fish that had passed through the regulating outlet.

  20. Leveraging long acting reversible contraceptives to achieve FP2020 commitments in sub-Saharan Africa: The potential of implants

    PubMed Central

    Garfinkel, Danielle; Riley, Christina; Esch, Keith; Girma, Woldemariam; Kebede, Tadele; Kasongo, Gaby; Afolabi, Kayode; Kalamar, Amanda; Thurston, Sarah; Longfield, Kim; Bertrand, Jane; Shaw, Bryan

    2018-01-01

    Background In developing regions, an estimated 214 million women have an unmet need for family planning. Reaching Family Planning 2020 (FP2020) commitments will require a shift in modern contraceptive promotion, including improved access to long-acting reversible contraceptives (LARCs). Until now, a lack of market data limited understanding of the potential of LARCs to increase contraceptive access and choice. Methods From 2015, the FPwatch Project conducted representative surveys in Ethiopia, Nigeria, and Democratic Republic of Congo (DRC) using a full census approach in selected administrative areas. In these areas, every public and private sector outlet with the potential to sell or distribute modern contraceptives was approached. In outlets with modern contraceptives, product audits and provider interviews assessed contraceptive market composition, market share, availability, price, and outlet readiness to perform services. Results Fifty-four percent of outlets in Ethiopia had LARC commodities or services available at the time of the survey, versus 7% and 8% of outlets in Nigeria and DRC, respectively. When present, LARCs were usually available with at least two other methods (99%, 39%, and 84% of public health facilities in Ethiopia, Nigeria and DRC, respectively). Many public facilities had both implants and IUDs in stock (76%, 47%, and 53%, respectively). Lack of readiness to provide LARCs was mostly due to a lack of equipment, private room, or the commodity itself. Market share for implants in the public sector was 60%, 53%, and 37% of Couple Years of Protection (CYP) in Ethiopia, Nigeria, and DRC. Discussion Limited availability of LARCs in Nigeria and DRC restricts contraceptive choice and makes it difficult for women to adopt and use modern contraception consistently. Brand-specific subsidies, task shifting, and promotion of methods that require less equipment and training are promising strategies for increasing uptake. Substantial government investment is required to improve availability and affordability. Investment in implants should be prioritized to make progress towards FP2020 commitments. PMID:29630607

  1. An evaluation of edge effects in nutritional accessibility and availability measures: a simulation study

    PubMed Central

    2010-01-01

    Background This paper addresses the statistical use of accessibility and availability indices and the effect of study boundaries on these measures. The measures are evaluated via an extensive simulation based on cluster models for local outlet density. We define outlet to mean either food retail store (convenience store, supermarket, gas station) or restaurant (limited service or full service restaurants). We designed a simulation whereby a cluster outlet model is assumed in a large study window and an internal subset of that window is constructed. We performed simulations on various criteria including one scenario representing an urban area with 2000 outlets as well as a non-urban area simulated with only 300 outlets. A comparison is made between estimates obtained with the full study area and estimates using only the subset area. This allows the study of the effect of edge censoring on accessibility measures. Results The results suggest that considerable bias is found at the edges of study regions in particular for accessibility measures. Edge effects are smaller for availability measures (when not smoothed) and also for short range accessibility Conclusions It is recommended that any study utilizing these measures should correct for edge effects. The use of edge correction via guard areas is recommended and the avoidance of large range distance-based accessibility measures is also proposed. PMID:20663199

  2. NanoSIMS results from olivine-hosted melt embayments: Modeling ascent rate in explosive basaltic eruptions

    NASA Astrophysics Data System (ADS)

    Lloyd, A. S.; Plank, T.; Ruprecht, P.; Hauri, E. H.; Gonnermann, H. M.; Rose, W. I.

    2012-12-01

    A critical parameter governing the explosivity of volcanic eruptions is the rate at which magma ascends and degases, because this affects bubble nucleation, coalescence, and ultimately fragmentation. Although several methods have been used to determine magma ascent rates, it remains a poorly constrained parameter for most eruptions. One promising method employs diffusion modeling of H2O and CO2 concentration gradients in melt embayments/open melt inclusions [1,2]. Here we utilize the fine spatial resolution of the nanoSIMS to obtain concentration gradients for five volatile species, improving upon previous efforts that were more limited in spatial resolution (FTIR, [1]) and in number of volatile analytes (H2O only by BSE, [2]). Focusing on explosive basaltic eruptions, for which very little is known about ascent rates, we chose ash and lapilli samples from the Oct 1974 sub-plinian eruption of Volcán de Fuego. Glassy, olivine-hosted embayments with evidence of outlet bubbles were analyzed by nanoSIMS at a minimum distance between spots of 15 μm. Major element zonation in the embayments was investigated by EMP, and high resolution BSE images were captured to complement the nanoSIMS spot measurements for H2O (as in [2]). We report analyses for 5 embayments that vary in length from 100 to 350 μm. Low-solubility volatiles (CO2, H2O, S) decrease towards the embayment outlet, consistent with diffusive reequilibration with the more-degassed surrounding melt. High-solubility volatiles (Cl, F) increase towards the outlet, apparently behaving as magmaphile elements. Major elements exhibit constant concentrations along the embayment, except for a 20-50 μm wide zone near the embayment outlet, perhaps representing a boundary layer at the outlet bubble, where concentrations vary consistent with olivine and clinopyroxene microlite growth. BSE grayscale values are thus affected by both H2O diffusion and major element zonation at the embayment outlet, and cannot be used to estimate H2O concentration gradients [2]. Forward modeling of CO2 and H2O profiles takes into account temperature- and composition-dependent diffusivities and a closed-system degassing path for the exterior magma (as observed in melt inclusions from the same sample). Assuming a constant decompression rate from 200 MPa and an initial composition of 600 ppm CO2 and 4.3 wt% H2O at 1030°C, models yield preliminary results with very rapid ascent times (100 s, or 2 MPa/s). A two-stage model, however, allows slower decompression during CO2 exsolution (0.1 MPa/s) and faster ascent when H2O begins to exsolve (1.5 MPa/s), for total ascent times on the order of 10 to 20 minutes. This example highlights the additional constraints that come from measuring multiple diffusing species. [1] Liu et al, JGR, 2007 [2] Humphreys et al, EPSL, 2008.

  3. Exergy analysis and simulation of a 30MW cogeneration cycle

    NASA Astrophysics Data System (ADS)

    Dev, Nikhil; Samsher; Kachhwaha, S. S.; Attri, Rajesh

    2013-06-01

    Cogeneration cycle is an efficient mean to recover the waste heat from the flue gases coming out of gas turbine. With the help of computer simulation, design parameters may be selected for the best performance of cogeneration cycle. In the present work a program is executed in software EES on the basis of mathematical modelling described in paper to study cogeneration cycle performance for different parameters. Results obtained are compared with the results available in literature and are found in good agreement with them. Real gas and water properties are inbuilt in the software. Results show that enthalpy of air entering the combustion chamber is higher than that of the flue gases at combustion chamber outlet. For different operative conditions, energy and exergy efficiencies follow similar trends; although, exergy efficiency values are always lower than the corresponding energy efficiency ones. From the results it is found that turbine outlet temperature (TIT) of 524°C is uniquely suited to efficient cogeneration cycle because it enables the transfer of heat from exhaust gas to the steam cycle to take place over a minimal temperature difference. This temperature range results in the maximum thermodynamic availability while operating with highest temperature and highest efficiency cogeneration cycle. Effect of cycle pressure ratio (CR), inlet air temperature (IAT) and water pressure at heat recovery steam generator (HRSG) inlet on the 30MW cogeneration cycle is also studied.

  4. Altitude Performance of Modified J71 Afterburner with Revised Engine Operating Conditions

    NASA Technical Reports Server (NTRS)

    Useller, James W.; Russey, Robert E.

    1955-01-01

    An investigation was conducted in an altitude test chamber at the NACA Lewis laboratory to determine the effect of a revision of the rated engine operating conditions and modifications to the afterburner fue1 system, flameholder, and shell cooling on the augmented performance of the J71-A-2 (x-29) turbo jet engine operating at altitude . The afterburner modifications were made by the manufacturer to improve the endurance at sea-level, high-pressure conditions and to reduce the afterburner shell temperatures. The engine operating conditions of rated rotational speed and turbine-outlet gas temperature were increased. Data were obtained at conditions simulating flight at a Mach number of 0.9 and at altitudes from 40,000 to 60,000 feet. The afterburner modifications caused a reduction in afterburner combustion efficiency. The increase in rated engine speed and turbine-outlet temperature coupled with the afterburner modifications resulted in the over-all thrust of the engine and afterburner being unchanged at a given afterburner equivalence ratio, while the specific fuel consumption was increased slightly. A moderate shift in the range of equivalence ratios over which the afterburner would operate was encountered, but the maximum operable altitude remained unaltered. The afterburner-shell temperatures were also slightly reduced because of the modifications to the afterburner.

  5. Design, Development, and Performance Evaluation of Solar Heating System for Disinfection of Domestic Roof-Harvested Rainwater

    PubMed Central

    Sangodoyin, A. Y.

    2015-01-01

    A box-type solar heater was designed, constructed, and used to determine the effect of solar heating on quality of domestic roof-harvested rainwater (DRHRW). During testing, naturally contaminated DRHRW was harvested in Ibadan, Nigeria, and released into the system at 93.96 Lh−1 (2.61 × 10−5 m3 s−1) in a continuous flow process. Water temperatures at inlet, within the heating chamber, and at outlet from the heating chamber and solar radiation were monitored at 10 min interval. Samples were collected at both inlet to and outlet from the heating chamber at 10 min interval for microbiological analysis. The highest plate stagnation temperature, under no-load condition, was 100°C. The solar water heater attained a maximum operational temperature of 75°C with 89.6 and 94.4% reduction in total viable count and total coliform count, respectively, while Escherichia coli and Staphylococcus aureus were completely eradicated at this temperature. The solar heater developed proved to be effective in enhancing potability of DRHRW in Ibadan, Nigeria. This may be an appropriate household water treatment technology for developing countries, hence, a way of resolving problem of low quality water for potable uses. PMID:27347529

  6. Design of aquaponics water monitoring system using Arduino microcontroller

    NASA Astrophysics Data System (ADS)

    Murad, S. A. Z.; Harun, A.; Mohyar, S. N.; Sapawi, R.; Ten, S. Y.

    2017-09-01

    This paper describes the design of aquaponics water monitoring system using Arduino microcontroller. Arduino Development Environment (IDE) software is used to develop a program for the microcontroller to communicate with multiple sensors and other hardware. The circuit of pH sensor, temperature sensor, water sensor, servo, liquid crystal displays (LCD), peristaltic pump, solar and Global System for Mobile communication (GSM) are constructed and connected to the system. The system powered by a rechargeable battery using solar energy. When the results of pH, temperature and water sensor are out of range, a notification message will be sent to a mobile phone through GSM. If the pH of water is out of range, peristaltic pump is automatic on to maintain back the pH value of water. The water sensor is fixed in the siphon outlet water flow to detect water flow from grow bed to the fish tank. In addition, servo is used to auto feeding the fish for every 12 hours. Meanwhile, the LCD is indicated the pH, temperature, siphon outlet water flow and remaining time for the next feeding cycle. The pH and temperature of water are set in the ranges of 6 to 7 and 25 °C to 30 °C, respectively.

  7. Design, Development, and Performance Evaluation of Solar Heating System for Disinfection of Domestic Roof-Harvested Rainwater.

    PubMed

    Akintola, O A; Sangodoyin, A Y

    2015-01-01

    A box-type solar heater was designed, constructed, and used to determine the effect of solar heating on quality of domestic roof-harvested rainwater (DRHRW). During testing, naturally contaminated DRHRW was harvested in Ibadan, Nigeria, and released into the system at 93.96 Lh(-1) (2.61 × 10(-5) m(3) s(-1)) in a continuous flow process. Water temperatures at inlet, within the heating chamber, and at outlet from the heating chamber and solar radiation were monitored at 10 min interval. Samples were collected at both inlet to and outlet from the heating chamber at 10 min interval for microbiological analysis. The highest plate stagnation temperature, under no-load condition, was 100°C. The solar water heater attained a maximum operational temperature of 75°C with 89.6 and 94.4% reduction in total viable count and total coliform count, respectively, while Escherichia coli and Staphylococcus aureus were completely eradicated at this temperature. The solar heater developed proved to be effective in enhancing potability of DRHRW in Ibadan, Nigeria. This may be an appropriate household water treatment technology for developing countries, hence, a way of resolving problem of low quality water for potable uses.

  8. Healthy food choices and physical activity opportunities in two contrasting Alabama cities.

    PubMed

    Bovell-Benjamin, A C; Hathorn, C S; Ibrahim, S; Gichuhi, P N; Bromfield, E M

    2009-06-01

    Food and physical activity access and availability in two contrasting cities in Alabama were investigated. An in-outlet, observational, cross-sectional design was utilized to assess the opportunities for healthy food choices and physical activity. Thirty retail food outlets and 29 physical activity outlets were inventoried. None of the convenience stores carried frozen, low-sodium or dark-green, yellow vegetables, low-fat milk or yogurt, low-sodium and low-fat cheese, while none of the supermarkets in Tuskegee stocked low-sodium vegetables. In Tuskegee, the single public recreational area, which offered activities such as basketball, fees ranged from $25 to $35/month. Tuskegee has a shortage of "chain" supermarkets and a dominance of convenience stores which stocked few healthy foods. Overall, there are limited opportunities for healthy food and physical activity choices, which could be a barrier for chronic disease prevention efforts.

  9. Observed Spatial and Temporal Variability of Subglacial Discharge-Driven Plumes in Greenland's Outlet Glacial Fjords

    NASA Astrophysics Data System (ADS)

    Sutherland, D.; Carroll, D.; Nash, J. D.; Shroyer, E.; Mickett, J.; Stearns, L. A.; Fried, M.; Bartholomaus, T.; Catania, G. A.

    2015-12-01

    Hydrographic and velocity observations in Greenland's outlet glacier fjords have revealed, unsurprisingly, a rich set of dynamics over a range of spatial and temporal scales. Through teasing apart the distinct processes that control circulation within these fjords, we are likely to better understand the impact of fjord circulation on modulating outlet glacier dynamics, and thus, changes in Greenland Ice Sheet mass balance. Here, we report on data from the summers of 2013-2015 in two neighboring fjords in the Uummannaq Bay region of west Greenland: Kangerlussuup Sermia (KS) and Rink Isbræ (RI). We find strong subglacial discharge driven plumes in both systems that evolve on synoptic and seasonal time scales, without the complicating presence of other circulation processes. The plumes both modify fjord water properties and respond to differences in ambient water properties, supporting the notion that a feedback exists between subglacial discharge plume circulation and water mass properties. This feedback between subglacial discharge and water properties potentially influences submarine melt rates at the glacier termini. Observed plume properties, including the vertical structure of velocity, and temperature and salinity anomalies, are compared favorably to model estimates. In KS, we find a near-surface intensified plume with high sediment content that slows and widens as it evolves downstream. In contrast, the plume in RI is entirely subsurface, ranging from 100-300 m depth at its core during summer, although it shows similar temperature, salinity, and optical backscatter signals to the KS plume. Importantly, the distinct vertical plume structures imprint on the overall water mass properties found in each fjord, raising the minimum temperatures by up to 1-2°C in the case of RI.

  10. Developing a Benchmarking Process in Perfusion: A Report of the Perfusion Downunder Collaboration

    PubMed Central

    Baker, Robert A.; Newland, Richard F.; Fenton, Carmel; McDonald, Michael; Willcox, Timothy W.; Merry, Alan F.

    2012-01-01

    Abstract: Improving and understanding clinical practice is an appropriate goal for the perfusion community. The Perfusion Downunder Collaboration has established a multi-center perfusion focused database aimed at achieving these goals through the development of quantitative quality indicators for clinical improvement through benchmarking. Data were collected using the Perfusion Downunder Collaboration database from procedures performed in eight Australian and New Zealand cardiac centers between March 2007 and February 2011. At the Perfusion Downunder Meeting in 2010, it was agreed by consensus, to report quality indicators (QI) for glucose level, arterial outlet temperature, and pCO2 management during cardiopulmonary bypass. The values chosen for each QI were: blood glucose ≥4 mmol/L and ≤10 mmol/L; arterial outlet temperature ≤37°C; and arterial blood gas pCO2 ≥ 35 and ≤45 mmHg. The QI data were used to derive benchmarks using the Achievable Benchmark of Care (ABC™) methodology to identify the incidence of QIs at the best performing centers. Five thousand four hundred and sixty-five procedures were evaluated to derive QI and benchmark data. The incidence of the blood glucose QI ranged from 37–96% of procedures, with a benchmark value of 90%. The arterial outlet temperature QI occurred in 16–98% of procedures with the benchmark of 94%; while the arterial pCO2 QI occurred in 21–91%, with the benchmark value of 80%. We have derived QIs and benchmark calculations for the management of several key aspects of cardiopulmonary bypass to provide a platform for improving the quality of perfusion practice. PMID:22730861

  11. A Review of Existing Studies Reporting the Negative Effects of Alcohol Access and Positive Effects of Alcohol Control Policies on Interpersonal Violence

    PubMed Central

    Fitterer, Jessica L.; Nelson, Trisalyn A.; Stockwell, Timothy

    2015-01-01

    Alcohol consumption often leads to elevated rates of violence yet alcohol access policies continue to relax across the globe. Our review establishes the extent alcohol policy can moderate violent crime through alcohol availability restrictions. Results were informed from comprehensive selection of peer-reviewed journals from 1950 to October 2015. Our search identified 87 relevant studies on alcohol access and violence conducted across 12 countries. Seventeen studies included quasi-control design, and 23 conducted intervention analysis. Seventy-one (82%) reported a significant relationship between alcohol access and violent offenses. Alcohol outlet studies reported the greatest percentage of significant results (93%), with trading hours (63%), and alcohol price following (58%). Results from baseline studies indicated the effectiveness of increasing the price of commonly consumed alcohol, restricting the hours of alcohol trading, and limiting the number of alcohol outlets per region to prevent violent offenses. Unclear are the effects of tax reductions, restriction of on-premises re-entry, and different outlet types on violent crime. Further, the generalization of statistics over broad areas and the low number of control/intervention studies poses some concern for confounding or correlated effects on study results, and amount of information for local-level prevention of interpersonal violence. Future studies should focus on gathering longitudinal data, validating models, limiting crime data to peak drinking days and times, and wherever possible collecting the joint distribution between violent crime, intoxication, and place. A greater uptake of local-level analysis will benefit studies comparing the influence of multiple alcohol establishment types by relating the location of a crime to establishment proximity. Despite, some uncertainties particular studies showed that even modest policy changes, such as 1% increases in alcohol price, 1 h changes to closing times, and limiting establishment densities to <25 outlets per postal code substantively reduce violent crime. PMID:26636055

  12. Tobacco retail outlet advertising practices and proximity to schools, parks and public housing affect Synar underage sales violations in Washington, DC.

    PubMed

    Kirchner, Thomas R; Villanti, Andrea C; Cantrell, Jennifer; Anesetti-Rothermel, Andrew; Ganz, Ollie; Conway, Kevin P; Vallone, Donna M; Abrams, David B

    2015-03-01

    To examine the cross-sectional association between illicit sales of tobacco to minors, Washington DC tobacco outlet advertising practices, retail store type, the demographic make-up of the area surrounding each outlet, and the proximity of each outlet to high schools, recreational parks and public housing. Seven hundred and fifty tobacco outlets in the DC area, n=347 of which were randomly selected for inspection by the Synar Inspection Program in 2009-2010. The presence of tobacco advertisements on the interior and exterior of each outlet, and illicit tobacco sales to Synar Inspection Program youth volunteers. The presence of tobacco advertisements on the exterior of gas stations was much greater than on other retail store types (OR=6.68; 95% CI 4.05 to 11.01), as was the absence of any advertisements at bars or restaurants that sold tobacco (OR=0.33; 95% CI 0.22 to 0.52). Exterior tobacco advertisements were also more likely in predominantly African-American areas of the city (OR=3.11; 95% CI 2.28 to 4.25), and particularly likely on storefronts located closer to parks (OR=1.87; 95% CI 1.06 to 3.28). Illicit sales to minors were more common at gas stations (OR=3.01; 95% CI 1.5 to 6.3), outlets that displayed exterior tobacco advertisements closer to parks (OR=3.36; 95% CI 1.38 to 8.21), and outlets located closer to high schools in majority African-American block groups (OR=1.29; 95% CI 1.07 to 1.58). Findings demonstrate that while illicit tobacco sales to minors are occurring at acceptably low rates by Synar standards, illicit sales vary considerably by retail store type, advertising approach and proximity to high schools, parks and African-American residential areas. Future work may help inform regulatory efforts to reduce youth access at the neighbourhood, city, state and national levels. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Bue, Grant; Hakam, Mary

    2012-01-01

    A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

  14. Getting to FP2020: Harnessing the private sector to increase modern contraceptive access and choice in Ethiopia, Nigeria, and DRC

    PubMed Central

    Garfinkel, Danielle; Thanel, Katherine; Esch, Keith; Workalemahu, Endale; Anyanti, Jennifer; Mpanya, Godéfroid; Binanga, Arsène; Pope, Jen; Longfield, Kim; Bertrand, Jane; Shaw, Bryan

    2018-01-01

    Background An estimated 214 million women have unmet need for family planning in developing regions. Improved utilization of the private sector is key to achieving universal access to a range of safe and effective modern contraceptive methods stipulated by FP2020 and SDG commitments. Until now, a lack of market data has limited understanding of the private sector’s role in increasing contraceptive coverage and choice. Methods In 2015, the FPwatch Project conducted representative outlet surveys in Ethiopia, Nigeria, and DRC using a full census approach in selected administrative areas. Every public and private sector outlet with the potential to sell or distribute modern contraceptives was approached. In outlets with modern contraceptives, product audits and provider interviews assessed contraceptive market composition, availability, and price. Findings Excluding general retailers, 96% of potential outlets in Ethiopia, 55% in Nigeria, and 41% in DRC had modern contraceptive methods available. In Ethiopia, 41% of modern contraceptive stocking outlets were in the private sector compared with approximately 80% in Nigeria and DRC where drug shops were dominant. Ninety-five percent of private sector outlets in Ethiopia had modern contraceptive methods available; 37% had three or more methods. In Nigeria and DRC, only 54% and 42% of private sector outlets stocked modern contraceptives with 5% and 4% stocking three or more methods, respectively. High prices in Nigeria and DRC create barriers to consumer access and choice. Discussion There is a missed opportunity to provide modern contraception through the private sector, particularly drug shops. Subsidies and interventions, like social marketing and social franchising, could leverage the private sector’s role in increasing access to a range of contraceptives. Achieving global FP2020 commitments depends on the expansion of national contraceptive policies that promote greater partnership and cooperation with the private sector and improvement of decisions around funding streams of countries with large populations and high unmet need like Ethiopia, Nigeria, and DRC. PMID:29444140

  15. Getting to FP2020: Harnessing the private sector to increase modern contraceptive access and choice in Ethiopia, Nigeria, and DRC.

    PubMed

    Riley, Christina; Garfinkel, Danielle; Thanel, Katherine; Esch, Keith; Workalemahu, Endale; Anyanti, Jennifer; Mpanya, Godéfroid; Binanga, Arsène; Pope, Jen; Longfield, Kim; Bertrand, Jane; Shaw, Bryan

    2018-01-01

    An estimated 214 million women have unmet need for family planning in developing regions. Improved utilization of the private sector is key to achieving universal access to a range of safe and effective modern contraceptive methods stipulated by FP2020 and SDG commitments. Until now, a lack of market data has limited understanding of the private sector's role in increasing contraceptive coverage and choice. In 2015, the FPwatch Project conducted representative outlet surveys in Ethiopia, Nigeria, and DRC using a full census approach in selected administrative areas. Every public and private sector outlet with the potential to sell or distribute modern contraceptives was approached. In outlets with modern contraceptives, product audits and provider interviews assessed contraceptive market composition, availability, and price. Excluding general retailers, 96% of potential outlets in Ethiopia, 55% in Nigeria, and 41% in DRC had modern contraceptive methods available. In Ethiopia, 41% of modern contraceptive stocking outlets were in the private sector compared with approximately 80% in Nigeria and DRC where drug shops were dominant. Ninety-five percent of private sector outlets in Ethiopia had modern contraceptive methods available; 37% had three or more methods. In Nigeria and DRC, only 54% and 42% of private sector outlets stocked modern contraceptives with 5% and 4% stocking three or more methods, respectively. High prices in Nigeria and DRC create barriers to consumer access and choice. There is a missed opportunity to provide modern contraception through the private sector, particularly drug shops. Subsidies and interventions, like social marketing and social franchising, could leverage the private sector's role in increasing access to a range of contraceptives. Achieving global FP2020 commitments depends on the expansion of national contraceptive policies that promote greater partnership and cooperation with the private sector and improvement of decisions around funding streams of countries with large populations and high unmet need like Ethiopia, Nigeria, and DRC.

  16. Modular heat exchanger

    DOEpatents

    Culver, Donald W.

    1978-01-01

    A heat exchanger for use in nuclear reactors includes a heat exchange tube bundle formed from similar modules each having a hexagonal shroud containing a large number of thermally conductive tubes which are connected with inlet and outlet headers at opposite ends of each module, the respective headers being adapted for interconnection with suitable inlet and outlet manifold means. In order to adapt the heat exchanger for operation in a high temperature and high pressure environment and to provide access to all tube ports at opposite ends of the tube bundle, a spherical tube sheet is arranged in sealed relation across the chamber with an elongated duct extending outwardly therefrom to provide manifold means for interconnection with the opposite end of the tube bundle.

  17. 40 CFR 1065.376 - Chiller NO2 penetration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... residual water vapor that passed through the chiller at the chiller's outlet temperature and pressure. (3... after major maintenance. (b) Measurement principles. A chiller removes water, which can otherwise interfere with a NOX measurement. However, liquid water remaining in an improperly designed chiller can...

  18. 40 CFR 1065.376 - Chiller NO2 penetration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... residual water vapor that passed through the chiller at the chiller's outlet temperature and pressure. (3... after major maintenance. (b) Measurement principles. A chiller removes water, which can otherwise interfere with a NOX measurement. However, liquid water remaining in an improperly designed chiller can...

  19. 40 CFR 1065.376 - Chiller NO2 penetration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... residual water vapor that passed through the chiller at the chiller's outlet temperature and pressure. (3... after major maintenance. (b) Measurement principles. A chiller removes water, which can otherwise interfere with a NOX measurement. However, liquid water remaining in an improperly designed chiller can...

  20. 40 CFR 63.1362 - Standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... or on the railcar or tank truck shall open during loading or as a result of diurnal temperature...). (13) The requirement to correct outlet concentrations from combustion devices to 3 percent oxygen in... the percent oxygen correction. If emissions are controlled with a vapor recovery system as specified...

  1. 40 CFR 63.1362 - Standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... or on the railcar or tank truck shall open during loading or as a result of diurnal temperature...). (13) The requirement to correct outlet concentrations from combustion devices to 3 percent oxygen in... the percent oxygen correction. If emissions are controlled with a vapor recovery system as specified...

  2. 40 CFR 63.1362 - Standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... or on the railcar or tank truck shall open during loading or as a result of diurnal temperature...). (13) The requirement to correct outlet concentrations from combustion devices to 3 percent oxygen in... the percent oxygen correction. If emissions are controlled with a vapor recovery system as specified...

  3. Cycle analysis of MCFC/gas turbine system

    NASA Astrophysics Data System (ADS)

    Musa, Abdullatif; Alaktiwi, Abdulsalam; Talbi, Mosbah

    2017-11-01

    High temperature fuel cells such as the solid oxide fuel cell (SOFC) and the molten carbonate fuel cell (MCFC) are considered extremely suitable for electrical power plant application. The molten carbonate fuel cell (MCFC) performances is evaluated using validated model for the internally reformed (IR) fuel cell. This model is integrated in Aspen Plus™. Therefore, several MCFC/Gas Turbine systems are introduced and investigated. One of this a new cycle is called a heat recovery (HR) cycle. In the HR cycle, a regenerator is used to preheat water by outlet air compressor. So the waste heat of the outlet air compressor and the exhaust gases of turbine are recovered and used to produce steam. This steam is injected in the gas turbine, resulting in a high specific power and a high thermal efficiency. The cycles are simulated in order to evaluate and compare their performances. Moreover, the effects of an important parameters such as the ambient air temperature on the cycle performance are evaluated. The simulation results show that the HR cycle has high efficiency.

  4. The relationship between proximity of tobacco retail outlets to schools and tobacco use among school personnel in sub-Saharan Africa.

    PubMed

    Agaku, Israel T; Adisa, Akinyele O; Omaduvie, Uyoyo T; Vardavas, Constantine I

    2014-12-01

    We investigated the impact of proximity of tobacco retail outlets to schools on tobacco-related behavior and attitudes of school personnel in sub-Saharan Africa. A pooled analysis of the 2006-2011 Global School Personnel Surveys from 19 sub-Saharan African countries was performed (n=12,201). Multivariate logistic regression analyses were applied to measure the relationship between proximity of tobacco outlets to school premises and school personnel's tobacco-related behavior and attitudes (p<0.05). Among all school personnel, there was a significant association between the presence of tobacco outlets on school premises and current cigarette smoking (adjusted odds ratio [aOR]=3.89; 95% confidence interval [CI]: 2.17-7.20), current smokeless tobacco use (aOR=2.63; 95%CI: 1.04-6.65), and permissiveness towards tobacco industry sponsorship activities in school (aOR=2.27; 95%CI: 1.37-3.78). Complete smoke-free school policies were associated with lower odds of current cigarette smoking (aOR=0.42; 95%CI: 0.23-0.74), but were not significantly associated with current smokeless tobacco use. Among lifetime any tobacco users, there was a significant association between the presence of tobacco outlets on school premises and use of combustible (aOR=2.03; 95%CI: 1.09-3.75) and smokeless (aOR=3.85; 95%CI: 1.51-9.81) tobacco products on campus within the past year. Policies limiting the distance of tobacco outlets from schools, coupled with complete tobacco-free school policies may reduce tobacco use among school personnel. Copyright © 2014. Published by Elsevier Inc.

  5. Endoscopic stenting versus operative gastrojejunostomy for malignant gastric outlet obstruction.

    PubMed

    Chandrasegaram, Manju D; Eslick, Guy D; Mansfield, Clare O; Liem, Han; Richardson, Mark; Ahmed, Sulman; Cox, Michael R

    2012-02-01

    Malignant gastric outlet obstruction represents a terminal stage in pancreatic cancer. Between 5% and 25% of patients with pancreatic cancer ultimately experience malignant gastric outlet obstruction. The aim in palliating patients with malignant gastric outlet obstruction is to reestablish an oral intake by restoring gastrointestinal continuity. This ultimately improves their quality of life in the advanced stages of cancer. The main drawback to operative bypass is the high incidence of delayed gastric emptying, particularly in this group of patients with symptomatic obstruction. This study aimed to compare surgical gastrojejunostomy and endoscopic stenting in palliation of malignant gastric outlet obstruction, acknowledging the diversity and heterogeneity of patients with this presentation. This retrospective study investigated patients treated for malignant gastric outlet obstruction from December 1998 to November 2008 at Nepean Hospital, Sydney, Australia. Endoscopic duodenal stenting was performed under fluoroscopic guidance for placement of the stent. The operative patients underwent open surgical gastrojejunostomy. The outcomes assessed included time to diet, hospital length of stay (LOS), biliary drainage procedures, morbidity, and mortality. Of the 45 participants in this study, 26 underwent duodenal stenting and 19 had operative bypass. Comparing the stenting and operative patients, the median time to fluid intake was respectively 0 vs. 7 days (P < 0.001), and the time to intake of solids was 2 vs. 9 days (P = 0.004). The median total LOS was shorter in the stenting group (11 vs. 25 days; P < 0.001), as was the median postprocedure LOS (5 vs. 10 days; P = 0.07). Endoscopic stenting is preferable to operative gastrojejunostomy in terms of shorter LOS, faster return to fluids and solids, and reduced morbidity and in-hospital mortality for patients with a limited life span.

  6. Experimental performance of the regenerator for the Chrysler upgraded automotive gas turbine engine

    NASA Technical Reports Server (NTRS)

    Winter, J. M.; Nussle, R. C.

    1982-01-01

    Automobile gas turbine engine regenerator performance was studied in a regenerator test facility that provided a satisfactory simulation of the actual engine operating environment but with independent control of airflow and gas flow. Velocity and temperature distributions were measured immediately downstream of both the core high-pressure-side outlet and the core low-pressure-side outlet. For the original engine housing, the regenerator temperature effectiveness was 1 to 2 percent higher than the design value, and the heat transfer effectiveness was 2 to 4 percent lower than the design value over the range of test conditions simulating 50 to 100 percent of gas generator speed. Recalculating the design values to account for seal leakage decreased the design heat transfer effectiveness to values consistent with those measured herein. A baffle installed in the engine housing high-pressure-side inlet provided more uniform velocities out of the regenerator but did not improve the effectiveness. A housing designed to provide more uniform axial flow to the regenerator was also tested. Although temperature uniformity was improved, the effectiveness values were not improved. Neither did 50-percent flow blockage (90 degree segment) applied to the high-pressure-side inlet change the effectiveness significantly.

  7. High temperature solar thermal receiver

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A design concept for a high temperature solar thermal receiver to operate at 3 atmospheres pressure and 2500 F outlet was developed. The performance and complexity of windowed matrix, tube-header, and extended surface receivers were evaluated. The windowed matrix receiver proved to offer substantial cost and performance benefits. An efficient and cost effective hardware design was evaluated for a receiver which can be readily interfaced to fuel and chemical processes or to heat engines for power generation.

  8. A Micro-delivery Approach for Studying Microvascular Responses to Localized Oxygen Delivery

    PubMed Central

    Ghonaim, Nour W.; Lau, Leo W. M.; Goldman, Daniel; Ellis, Christopher G.; Yang, Jun

    2011-01-01

    In vivo video microscopy has been used to study blood flow regulation as a function of varying oxygen concentration in microcirculatory networks. However, previous studies have measured the collective response of stimulating large areas of the microvascular network at the tissue surface. Objective We aim to limit the area being stimulated by controlling oxygen availability to highly localized regions of the microvascular bed within intact muscle. Design and Method Gas of varying O2 levels was delivered to specific locations on the surface of the Extensor Digitorum Longus muscle of rat through a set of micro-outlets (100 μm diameter) patterned in ultrathin glass using state-of-the-art microfabrication techniques. O2 levels were oscillated and digitized video sequences were processed for changes in capillary hemodynamics and erythrocyte O2 saturation. Results and Conclusions Oxygen saturations in capillaries positioned directly above the micro-outlets were closely associated with the controlled local O2 oscillations. Radial diffusion from the micro-outlet is limited to ~75 μm from the center as predicted by computational modelling and as measured in vivo. These results delineate a key step in the design of a novel micro-delivery device for controlled oxygen delivery to the microvasculature to understand fundamental mechanisms of microvascular regulation of O2 supply. PMID:21914035

  9. 40 CFR 60.697 - Recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... shall maintain continuous records of the temperature of the gas stream in the combustion zone of the... of an affected facility that uses a catalytic incinerator shall maintain continuous records of the... continuous records of the VOC concentration level or reading of organics of the control device outlet gas...

  10. 40 CFR 60.697 - Recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shall maintain continuous records of the temperature of the gas stream in the combustion zone of the... of an affected facility that uses a catalytic incinerator shall maintain continuous records of the... continuous records of the VOC concentration level or reading of organics of the control device outlet gas...

  11. INFLUENCE OF RESIDENTIAL HVAC DUTY CYCLE ON INDOOR AIR QUALITY

    EPA Science Inventory

    Measurements of duty cycle, the fraction of time the heating and cooling (HVAC) system was operating, were made in homes during the spring season of the RTP Particulate Matter Panel Study and the Tampa Asthmatic Children's Study. A temperature sensor/logger placed on an outlet...

  12. Alcohol Outlet Characteristics and Alcohol Sales to Youth: Results of Alcohol Purchase Surveys in 45 Oregon Communities

    PubMed Central

    Paschall, Mallie J.; Grube, Joel W.; Black, Carol; Flewelling, Robert L.; Ringwalt, Christopher L.; Biglan, Anthony

    2007-01-01

    Reducing youth access to commercial sources of alcohol is recognized as a necessary component of a comprehensive strategy to reduce underage drinking and alcohol-related problems. However, research on policy-relevant factors that may influence the commercial availability of alcohol to youth is limited. The present study examines characteristics of off-premise alcohol outlets that may affect alcohol sales to youth. Random alcohol purchase surveys (N = 385) were conducted in 45 Oregon communities in 2005. Underage-looking decoys who were 21 years old but did not carry IDs were able to purchase alcohol at 34% of the outlets approached. Purchase rates were highest at convenience (38%) and grocery (36%) stores but were relatively low (14%) at other types of outlets (e.g., liquor and drug stores). Alcohol purchases were less likely at stores that were participating in the Oregon Liquor Control Commission's Responsible Vendor Program (RVP), when salesclerks asked the decoys for their IDs, and at stores with a posted underage alcohol sale warning sign. Alcohol purchases were also inversely related to the number of salesclerks present in a store, but were not related to salesclerks' age and gender. Findings of this study suggest that more frequent compliance checks by law enforcement agents should target convenience and grocery stores, and owners of off-premise outlets should require training of all salesclerks to ensure reliable checks of young-looking patron IDs, and should post underage alcohol sales warning signs in clear view of patrons. PMID:17243019

  13. The effects of opening areas on solar chimney performance

    NASA Astrophysics Data System (ADS)

    Ling, L. S.; Rahman, M. M.; Chu, C. M.; Misaran, M. S. bin; Tamiri, F. M.

    2017-07-01

    To enhance natural ventilation at day time, solar chimney is one of the suitable options for topical country like Malaysia. Solar chimney creates air flow due to stack effect caused by temperature difference between ambient and inside wall. In the solar chimney, solar energy is harvested by the inner wall that cause temperature rise compare to ambient. Therefore, the efficiency of the solar chimney depends on the availability of solar energy as well as the solar intensity. In addition, it is very hard to get good ventilation at night time by using a solar chimney. To overcome this problem one of the suitable valid option is to integrate solar chimney with turbine ventilator. A new type of solar chimney is designed and fluid flow analyzed with the computational fluid dynamics (CFD) software. The aim of CFD and theoretical study are to investigate the effect of opening areas on modified solar chimney performance. The inlet and outlet area of solar chimney are varied from 0.0224m2 to 0.6m2 and 0.1m2 to 0.14m2 respectively based on the changes of inclination angle and gap between inner and outer wall. In the CFD study the constant heat flux is considered as 500W/m2. CFD result shows that there is no significant relation between opening areas and the air flow rate through solar chimney but the ratio between inlet and outlet is significant on flow performance. If the area ratio between inlet and outlet are equal to two or larger, the performance of the solar chimney is better than the solar chimney with ratio lesser than two. The solar chimney performance does not effect if the area ratio between inlet and outlet varies from 1 to 2. This result will be useful for design and verification of actual solar chimney performance.

  14. Compressor ported shroud for foil bearing cooling

    DOEpatents

    Elpern, David G [Los Angeles, CA; McCabe, Niall [Torrance, CA; Gee, Mark [South Pasadena, CA

    2011-08-02

    A compressor ported shroud takes compressed air from the shroud of the compressor before it is completely compressed and delivers it to foil bearings. The compressed air has a lower pressure and temperature than compressed outlet air. The lower temperature of the air means that less air needs to be bled off from the compressor to cool the foil bearings. This increases the overall system efficiency due to the reduced mass flow requirements of the lower temperature air. By taking the air at a lower pressure, less work is lost compressing the bearing cooling air.

  15. 40 CFR 63.3493 - What work practice standards must I meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... or the control efficiency/outlet concentration option to comply with the emission limitations, you... materials, and waste materials must be conveyed from one location to another in closed containers or pipes...

  16. Hydrologic response to valley-scale structure in alpine headwaters

    USGS Publications Warehouse

    Weekes, Anne A.; Torgersen, Christian E.; Montgomery, David R.; Woodward, Andrea; Bolton, Susan M.

    2015-01-01

    To better evaluate potential differences in streamflow response among basins with extensive coarse depositional features and those without, we examined the relationships between streamflow discharge, stable isotopes, water temperature and the amplitude of the diurnal signal at five basin outlets. We also quantified the percentages of colluvial channel length measured along the stepped longitudinal profile. Colluvial channels, characterized by the presence of surficial, coarse-grained depositional features, presented sediment-rich, transport-limited morphologies that appeared to have a cumulative effect on the timing and volume of flow downstream. Measurements taken from colluvial channels flowing through depositional landforms showed median recession constants (Kr) of 0.9-0.95, δ18O values of ≥−14.5 and summer diurnal amplitudes ≤0.8 as compared with more typical surface water recession constant values of 0.7, δ18O ≤ −13.5 and diurnal amplitudes >2.0. Our results demonstrated strong associations between the percentage of colluvial channel length within a catchment and moderated streamflow regimes, water temperatures, diurnal signals and depleted δ18O related to groundwater influx.

  17. Control Performance of General Electric Fuel and Torque Regulator Operating on T31-3 Turbine-Propeller Engine in Sea-Level Test Stand

    NASA Technical Reports Server (NTRS)

    Oppenheimer, Frank L.; Lazar, James

    1951-01-01

    A .General Electric fuel and torque regulator was tested in conjunction with a T31-3 turbine-propeller engine in the sea-level static test stand at the NACA Lewis laboratory. The engine and control were operated over the entire speed range: 11,000 rpm, nominal flight idle, to 13,000 rpm, full power. Steady-state and transient data were recorded and are presented with a description of the four control loops being used in the system. Results of this investigation indicated that single-lever control operation was satisfactory under conditions of test. Transient data presented showed that turbine-outlet temperature did overshoot maximum operating value on acceleration but that the time duration of overshoot did not exceed approximately 1 second. This temperature limiting resulted from a control on fuel flow as a function of engine speed. Speed and torque first reached their desired values 0.4 second from the time of change in power-setting lever position. Maximum speed overshoot was 3 percent.

  18. Design modification for the modular helium reactor for higher temperature operation and reliability studies for nuclear hydrogen production processes

    NASA Astrophysics Data System (ADS)

    Reza, S. M. Mohsin

    Design options have been evaluated for the Modular Helium Reactor (MHR) for higher temperature operation. An alternative configuration for the MHR coolant inlet flow path is developed to reduce the peak vessel temperature (PVT). The coolant inlet path is shifted from the annular path between reactor core barrel and vessel wall through the permanent side reflector (PSR). The number and dimensions of coolant holes are varied to optimize the pressure drop, the inlet velocity, and the percentage of graphite removed from the PSR to create this inlet path. With the removal of ˜10% of the graphite from PSR the PVT is reduced from 541°C to 421°C. A new design for the graphite block core has been evaluated and optimized to reduce the inlet coolant temperature with the aim of further reduction of PVT. The dimensions and number of fuel rods and coolant holes, and the triangular pitch have been changed and optimized. Different packing fractions for the new core design have been used to conserve the number of fuel particles. Thermal properties for the fuel elements are calculated and incorporated into these analyses. The inlet temperature, mass flow and bypass flow are optimized to limit the peak fuel temperature (PFT) within an acceptable range. Using both of these modifications together, the PVT is reduced to ˜350°C while keeping the outlet temperature at 950°C and maintaining the PFT within acceptable limits. The vessel and fuel temperatures during low pressure conduction cooldown and high pressure conduction cooldown transients are found to be well below the design limits. The reliability and availability studies for coupled nuclear hydrogen production processes based on the sulfur iodine thermochemical process and high temperature electrolysis process have been accomplished. The fault tree models for both these processes are developed. Using information obtained on system configuration, component failure probability, component repair time and system operating modes and conditions, the system reliability and availability are assessed. Required redundancies are made to improve system reliability and to optimize the plant design for economic performance. The failure rates and outage factors of both processes are found to be well below the maximum acceptable range.

  19. Technical evaluation of a tank-connected food waste disposer system for biogas production and nutrient recovery.

    PubMed

    Davidsson, Å; Bernstad Saraiva, A; Magnusson, N; Bissmont, M

    2017-07-01

    In this study, a tank-connected food waste disposer system with the objective to optimise biogas production and nutrient recovery from food waste in Malmö was evaluated. The project investigated the source-separation ratio of food waste through waste composition analyses, determined the potential biogas production in ground food waste, analysed the organic matter content and the limiting components in ground food waste and analysed outlet samples to calculate food waste losses from the separation tank. It can be concluded that the tank-connected food waste disposer system in Malmö can be used for energy recovery and optimisation of biogas production. The organic content of the collected waste is very high and contains a lot of energy rich fat and protein, and the methane potential is high. The results showed that approximately 38% of the food waste dry matter is collected in the tank. The remaining food waste is either found in residual waste (34% of the dry matter) or passes the tank and goes through the outlet to the sewer (28%). The relatively high dry matter content in the collected fraction (3-5% DM) indicates that the separation tank can thicken the waste substantially. The potential for nutrient recovery is rather limited considering the tank content. Only small fractions of the phosphorus (15%) and nitrogen (21%) are recyclable by the collected waste in the tank. The quality of the outlet indicates a satisfactory separation of particulate organic matter and fat. The organic content and nutrients, which are in dissolved form, cannot be retained in the tank and are rather led to the sewage via the outlet. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Low head oxygenator performance characterization for marine recirculating aquaculture systems

    USDA-ARS?s Scientific Manuscript database

    This study evaluated the effect of temperature (20 and 25 ºC), salinity (10, 15, and 20 ppt), and dissolved oxygen levels within low head oxygenator (LHO) outlet water on oxygen transfer efficiency (OTE) of LHOs for a planned marine recirculating aquaculture system (RAS). Test results indicated tha...

  1. 33 CFR 154.826 - Vapor compressors and blowers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Excessive shaft bearing temperature. (d) If a centrifugal compressor, fan, or lobe blower handles vapor in... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vapor compressors and blowers....826 Vapor compressors and blowers. (a) Each inlet and outlet to a compressor or blower which handles...

  2. 46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...

  3. 46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...

  4. 46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...

  5. 46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...

  6. 46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...

  7. Production of hydrogen by direct gasification of coal with steam using nuclear heat

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Problems related to: (1) high helium outlet temperature of the reactor, and (2) gas generator design used in hydrogen production are studied. Special attention was given to the use of Oklahoma coal in the gasification process. Plant performance, operation, and environmental considerations are covered.

  8. THE WATER BALANCE OF THE SUSQUEHANNA RIVER BASIN AND ITS RESPONSE TO CLIMATE CHANGE. (R824995)

    EPA Science Inventory

    Abstract

    Historical precipitation, temperature and streamflow data for the Susquehanna River Basin (SRB) are analyzed with the objective of developing simple statistical and water balance models of streamflow at the watershed's outlet. Annual streamflow is highly corre...

  9. Effects of simultaneous climate change and geomorphic evolution on thermal characteristics of a shallow Alaskan lake

    USGS Publications Warehouse

    Griffiths, Jennifer R.; Schindler, Daniel E.; Balistrieri, Laurie S.; Ruggerone, Gregory T.

    2011-01-01

    We used a hydrodynamics model to assess the consequences of climate warming and contemporary geomorphic evolution for thermal conditions in a large, shallow Alaskan lake. We evaluated the effects of both known climate and landscape change, including rapid outlet erosion and migration of the principal inlet stream, over the past 50 yr as well as future scenarios of geomorphic restoration. Compared to effects of air temperature during the past 50 yr, lake thermal properties showed little sensitivity to substantial (~60%) loss of lake volume, as the lake maximum depth declined from 6 m to 4 m driven by outlet erosion. The direction and magnitude of future lake thermal responses will be driven largely by the extent of inlet stream migration when it occurs simultaneously with outlet erosion. Maintaining connectivity with inlet streams had substantial effects on buffering lake thermal responses to warming climate. Failing to account for changing rates and types of geomorphic processes under continuing climate change may misidentify the primary drivers of lake thermal responses and reduce our ability to understand the consequences for aquatic organisms.

  10. Method for analyzing the chemical composition of liquid effluent from a direct contact condenser

    DOEpatents

    Bharathan, Desikan; Parent, Yves; Hassani, A. Vahab

    2001-01-01

    A computational modeling method for predicting the chemical, physical, and thermodynamic performance of a condenser using calculations based on equations of physics for heat, momentum and mass transfer and equations of equilibrium thermodynamics to determine steady state profiles of parameters throughout the condenser. The method includes providing a set of input values relating to a condenser including liquid loading, vapor loading, and geometric characteristics of the contact medium in the condenser. The geometric and packing characteristics of the contact medium include the dimensions and orientation of a channel in the contact medium. The method further includes simulating performance of the condenser using the set of input values to determine a related set of output values such as outlet liquid temperature, outlet flow rates, pressures, and the concentration(s) of one or more dissolved noncondensable gas species in the outlet liquid. The method may also include iteratively performing the above computation steps using a plurality of sets of input values and then determining whether each of the resulting output values and performance profiles satisfies acceptance criteria.

  11. Characteristics Air Flow in Room Chamber Test Refrigerator Household Energy Consumption with Inlet Flow Variation

    NASA Astrophysics Data System (ADS)

    Susanto, Edy; Idrus Alhamid, M.; Nasruddin; Budihardjo

    2018-03-01

    Room Chamber is the most important in making a good Testing Laboratory. In this study, the 2-D modeling conducted to assess the effect placed the inlet on designing a test chamber room energy consumption of household refrigerators. Where the geometry room chamber is rectangular and approaching the enclosure conditions. Inlet varied over the side parallel to the outlet and compared to the inlet where the bottom is made. The purpose of this study was to determine and define the characteristics of the airflow in the room chamber using CFD simulation. CFD method is used to obtain flow characteristics in detail, in the form of vector flow velocity and temperature distribution inside the chamber room. The result found that the position of the inlet parallel to the outlet causes air flow cannot move freely to the side of the floor, even flow of air moves up toward the outlet. While by making the inlet is below, the air can move freely from the bottom up to the side of the chamber room wall as well as to help uniform flow.

  12. Short and long term chemical and isotopic variations of Lake Trasimeno (Italy)

    NASA Astrophysics Data System (ADS)

    Frondini, Francesco; Dragoni, Walter; Chiodini, Giovanni; Caliro, Stefano; Cardellini, Carlo; Donnini, Marco; Morgantini, Nicola

    2016-04-01

    Lake Trasimeno, located in Umbria (central Italy), is a shallow lake of a remarkable naturalistic interest and a significant resource for the economy of the region (Ludovisi and Gaino, 2010; Dragoni, 2004). The Lake Trasimeno has an average area of about 124 km2 with a maximum depth of approximately 5.5 m, has no natural outlet and the volume of water stored is strictly linked to rainfall. In order to limit water level variations in 1898 an efficient outlet was built. At present the water exits from the Lake only when the level reaches a fixed threshold above the outlet channel, so during periods with low precipitation the evaporation becomes the most relevant output from the lake. For instance, between 1989 and 2013 the outlet did not work, and the maximum depth of the lake was reduced to little more than three meters. In the framework of climate change, it is important to understand the changes that could affect Lake Trasimeno in the near future. To this aim it is necessary to individuate the long term trends of the hydrologic, chemical and physical characteristics of the Trasimeno water and distinguish them from the short term variations. At the present it is available a long record of hydrologic data allowing reliable studies on quantitative variations at Lake Trasimeno (Dragoni et al., 2015; Dragoni et al., 2012; Ludovisi and Gaino, 2010), but the definition of the chemical and isotopic trends of lake water it is still a problematic task. On the basis of new chemical and isotopic data, collected from 2006 to 2015, it is possible to observe (i) short term and/or very short (seasonal) variations in temperature, salinity and saturation state with respect to carbonate minerals and a long term trends in isotopic composition of water and total load of mobile species (Cl, Na). The short term variations readily respond to the precipitation regime and are strongly related to lake level; the long term trend is probably related to the progressive increase of near-surface atmospheric temperature observed in the last decades. References - Dragoni W., et al. (2015) - Possible response of two water systems in Central Italy to climatic changes. In "Advances in Watershed Hydrology" (T. Moramarco, S. Barbetta, L. Brocca, Eds), pp.397-424. Publications, LLC, USA. ISBN-13: 978-1-887-20185-8 - Dragoni W., et al. (2012): Bilancio idrico del Lago Trasimeno. In "Tutela Ambientale del lago Trasimeno", a cura di Martinelli A., Libri/Arpa Umbria, pp. 403. ISBN: 978-88-905920-03 (in Italian). - Dragoni W. (2004): The Lake Trasimeno and the Climatic Variations - Il Lago Trasimeno e le Variazioni Climatiche. Progetto informativo dell'assessorato all'Ambiente della Provincia di Perugia, Servizio Gestione e Difesa Idraulica, pp. 60, Perugia. - Ludovisi, A., Gaino, E., 2010. Meteorological and water quality changes in Lake Trasimeno (Umbria, Italy) during the last fifty years. J. Limnol. 69, 174-188.

  13. Control Algorithms For Liquid-Cooled Garments

    NASA Technical Reports Server (NTRS)

    Drew, B.; Harner, K.; Hodgson, E.; Homa, J.; Jennings, D.; Yanosy, J.

    1988-01-01

    Three algorithms developed for control of cooling in protective garments. Metabolic rate inferred from temperatures of cooling liquid outlet and inlet, suitably filtered to account for thermal lag of human body. Temperature at inlet adjusted to value giving maximum comfort at inferred metabolic rate. Applicable to space suits, used for automatic control of cooling in suits worn by workers in radioactive, polluted, or otherwise hazardous environments. More effective than manual control, subject to frequent, overcompensated adjustments as level of activity varies.

  14. A general method to analyze the thermal performance of multi-cavity concentrating solar power receivers

    DOE PAGES

    Fleming, Austin; Folsom, Charles; Ban, Heng; ...

    2015-11-13

    Concentrating solar power (CSP) with thermal energy storage has potential to provide grid-scale, on-demand, dispatachable renewable energy. As higher solar receiver output temperatures are necessary for higher thermal cycle efficiency, current CSP research is focused on high outlet temperature and high efficiency receivers. Here, the objective of this study is to provide a simplified model to analyze the thermal efficiency of multi-cavity concentrating solar power receivers.

  15. Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia.

    PubMed

    Poder, Thomas G; Pruneau, Denise; Dorval, Josée; Thibault, Louis; Fisette, Jean-François; Bédard, Suzanne K; Jacques, Annie; Beauregard, Patrice

    2016-01-01

    Blood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used. Pressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested. We found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C. To use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia.

  16. CFD-based Analysis of Non-Premixed Combustion Model in Biomass Grate Furnaces

    NASA Astrophysics Data System (ADS)

    Hafiz, M.; Nelwan, L. O.; Yulianto, M.

    2018-05-01

    Biomass grate furnace is widely used as heat source for various uses including grain drying. In this study, a CFD simulation using Fluent 18.0 academic was performed on a biomass ladder grate furnace, which can be used later to improve the design as well as the operation technique of the furnace. A downscaled overfeed type furnace with size of 15 x 30 x 50 cm was built to validate the model. The turbulence model used in this study was k-epsilon while the combustion model of non-premixed combustion was used. The simulation was performed with the biomass feed rate of 4 kg/h and air flow velocity of 7.5 m/s at 3.81 cm inlet diameter. The simulation result at outlet temperature was 673 °C and inside temperature were 775 and 717 °C, while the composition of gases was 0.18 for CO, 0.2 for CO2, 0.001 for CH4, 0.09 for H2O, 0.51 for N2 and 0.029 for other gases. Test results from a biomass ladder grate furnace were used to validate the model and the results are 646 °C for the outlet temperature, 712 and 582 °C for inside temperature. Comparison between simulation and measurement results shows good value with average percentage of deviation 12.12%.

  17. Modeling Of Metabolic Heat Regenerated Temperature Swing Adsorption (MTSA) Subassembly For Prototype Design

    NASA Technical Reports Server (NTRS)

    Bower, Chad E.; Padilla, Sebastian A.; Iacomini, Christie S.; Paul, Heather L.

    2010-01-01

    This paper describes modeling methods for the three core components of a Metabolic heat regenerated Temperature Swing Adsorption (MTSA) subassembly: a sorbent bed, a sublimation (cooling) heat exchanger (SHX), and a condensing icing (warming) heat exchanger (CIHX). The primary function of the MTSA, removing carbon dioxide from a space suit Portable Life Support System (PLSS) ventilation loop, is performed via the sorbent bed. The CIHX is used to heat the sorbent bed for desorption and to remove moisture from the ventilation loop while the SHX is alternately employed to cool the sorbent bed via sublimation of a spray of water at low pressure to prepare the reconditioned bed for the next cycle. This paper describes subsystem heat a mass transfer modeling methodologies relevant to the description of the MTSA subassembly in Thermal Desktop and SINDA/FLUINT. Several areas of particular modeling interest are discussed. In the sorbent bed, capture of the translating carbon dioxide (CO2) front and associated local energy and mass balance in both adsorbing and desorbing modes is covered. The CIHX poses particular challenges for modeling in SINDA/FLUINT as accounting for solids states in fluid submodels are not a native capability. Methods for capturing phase change and latent heat of ice as well as the transport properties across a layer of low density accreted frost are developed. This extended modeling capacity is applicable to temperatures greater than 258 K. To extend applicability to the minimum device temperature of 235 K, a method for a mapped transformation of temperatures from below the limit temperatures to some value above is given along with descriptions for associated material property transformations and the resulting impacts to total heat and mass transfer. Similar considerations are given for the SHX along with functional relationships for areal sublimation rates as limited by flow mechanics in t1he outlet duct.

  18. 'McDonalds and KFC, it's never going to happen': the challenges of working with food outlets to tackle the obesogenic environment.

    PubMed

    Hanratty, Barbara; Milton, Beth; Ashton, Matthew; Whitehead, Margaret

    2012-12-01

    Food outlets may make an important contribution to an obesogenic environment. This study investigated barriers and facilitators to public health work with food outlets in disadvantaged areas. In-depth qualitative interviews with 36 directors, managers and public health service delivery staff in a coterminous primary care trust and local authority in northwest England. Data were analysed using the constant comparative method. Three interventions were available to engage with businesses; awards for premises that welcomed breastfeeding mothers or offered healthy menu options and local authority planning powers. Sensitivity to the potential conflict between activities that generate profit and those that promote health, led to compromises, such as awards for cafés that offer only one healthy option on an otherwise unhealthy menu. An absence of existing relationships with businesses and limited time were powerful disincentives to action, leading to greater engagement with public rather than private sector organizations. Hiring staff with commercial experience and incentives for businesses were identified as useful strategies, but seldom used. Encouraging food outlets to contribute to tackling the obesogenic environment is a major challenge for local public health teams that requires supportive national policies. Commitment to engage with the local public health service should be part of any national voluntary agreements with industry.

  19. Inland thinning on the Greenland ice sheet controlled by outlet glacier geometry

    NASA Astrophysics Data System (ADS)

    Felikson, Denis; Bartholomaus, Timothy C.; Catania, Ginny A.; Korsgaard, Niels J.; Kjær, Kurt H.; Morlighem, Mathieu; Noël, Brice; van den Broeke, Michiel; Stearns, Leigh A.; Shroyer, Emily L.; Sutherland, David A.; Nash, Jonathan D.

    2017-04-01

    Greenland’s contribution to future sea-level rise remains uncertain and a wide range of upper and lower bounds has been proposed. These predictions depend strongly on how mass loss--which is focused at the termini of marine-terminating outlet glaciers--can penetrate inland to the ice-sheet interior. Previous studies have shown that, at regional scales, Greenland ice sheet mass loss is correlated with atmospheric and oceanic warming. However, mass loss within individual outlet glacier catchments exhibits unexplained heterogeneity, hindering our ability to project ice-sheet response to future environmental forcing. Using digital elevation model differencing, we spatially resolve the dynamic portion of surface elevation change from 1985 to present within 16 outlet glacier catchments in West Greenland, where significant heterogeneity in ice loss exists. We show that the up-glacier extent of thinning and, thus, mass loss, is limited by glacier geometry. We find that 94% of the total dynamic loss occurs between the terminus and the location where the down-glacier advective speed of a kinematic wave of thinning is at least three times larger than its diffusive speed. This empirical threshold enables the identification of glaciers that are not currently thinning but are most susceptible to future thinning in the coming decades.

  20. Water augmented indirectly-fired gas turbine systems and method

    DOEpatents

    Bechtel, Thomas F.; Parsons, Jr., Edward J.

    1992-01-01

    An indirectly-fired gas turbine system utilizing water augmentation for increasing the net efficiency and power output of the system is described. Water injected into the compressor discharge stream evaporatively cools the air to provide a higher driving temperature difference across a high temperature air heater which is used to indirectly heat the water-containing air to a turbine inlet temperature of greater than about 1,000.degree. C. By providing a lower air heater hot side outlet temperature, heat rejection in the air heater is reduced to increase the heat recovery in the air heater and thereby increase the overall cycle efficiency.

  1. Access to food retail outlets in County Durham, UK: a pragmatic cross-sectional study.

    PubMed

    Mills, Susanna; Wright, Tim

    2015-02-26

    Strong links exist between deprivation, obesity, and dietary quality. Increasing interest has focussed on the concept of access to food and so-called food deserts, defined by a policy working group of the UK Low Income Project Team in 1995 as "areas of relative exclusion where people experience physical and economic barriers to accessing healthy food". We aimed to establish the accessibility of food retail outlets in County Durham, a county in north-east England, UK, considering physical access, affordability, and food range and quality. In a pragmatic cross-sectional study in County Durham, we used information from town surveys and food business databases to locate and identify food retail outlets. The prevalence of deprivation, obesity, retail outlets, takeaway outlets, and ratio of retail to takeaway outlets was mapped, to establish local food access, and any associations with deprivation and obesity. The times taken to travel from residences to supermarkets using private car and public transport were also measured. 400 members of the community participated in eight focus groups and commissioned on-street surveys. Focus group transcripts were reviewed alongside the on-street survey responses to identify key issues. Most residents shopped at least weekly for food (n=368, 92%), used a supermarket for their main food shop (372, 93%), travelled for up to 15 min (340, 85%), and used a car for transport (188, 47%). Many survey respondents indicated high levels of satisfaction with food retail outlets (average rating 8·7 out of 10 for agreement with the statement "Overall I am satisfied with the shop where I do my main food shopping"), although financial constraints and transport inconvenience were identified as barriers. Difficulties with food shopping were more widely described in focus groups, and many individuals felt that local shopping provision had declined, with an emergent excess of takeaway outlets. Food retail access was reduced for the disabled, full-time workers, elderly people, and people with children. These findings suggest a potential role for individual behaviour change, planning and policy bodies, and the food retail industry in addressing food access. The multiple methods used in this study enabled triangulation; however, the conclusions are limited by the pragmatic nature of data collection and analysis. Durham County Council. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Gas flow headspace liquid phase microextraction.

    PubMed

    Yang, Cui; Qiu, Jinxue; Ren, Chunyan; Piao, Xiangfan; Li, Xifeng; Wu, Xue; Li, Donghao

    2009-11-06

    There is a trend towards the use of enrichment techniques such as microextraction in the analysis of trace chemicals. Based on the theory of ideal gases, theory of gas chromatography and the original headspace liquid phase microextraction (HS-LPME) technique, a simple gas flow headspace liquid phase microextraction (GF-HS-LPME) technique has been developed, where the extracting gas phase volume is increased using a gas flow. The system is an open system, where an inert gas containing the target compounds flows continuously through a special gas outlet channel (D=1.8mm), and the target compounds are trapped on a solvent microdrop (2.4 microL) hanging on the microsyringe tip, as a result, a high enrichment factor is obtained. The parameters affecting the enrichment factor, such as the gas flow rate, the position of the microdrop, the diameter of the gas outlet channel, the temperatures of the extracting solvent and of the sample, and the extraction time, were systematically optimized for four types of polycyclic aromatic hydrocarbons. The results were compared with results obtained from HS-LPME. Under the optimized conditions (where the extraction time and the volume of the extracting sample vial were fixed at 20min and 10mL, respectively), detection limits (S/N=3) were approximately a factor of 4 lower than those for the original HS-LPME technique. The method was validated by comparison of the GF-HS-LPME and HS-LPME techniques using data for PAHs from environmental sediment samples.

  3. 40 CFR 63.3491 - What are my options for meeting the emission limits?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., total HAP emissions measured as total hydrocarbon (THC) are reduced by 95 percent or greater for existing sources, or 97 percent or greater for new or reconstructed sources, or that outlet THC emissions...

  4. 40 CFR 63.3491 - What are my options for meeting the emission limits?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., total HAP emissions measured as total hydrocarbon (THC) are reduced by 95 percent or greater for existing sources, or 97 percent or greater for new or reconstructed sources, or that outlet THC emissions...

  5. 40 CFR 63.3491 - What are my options for meeting the emission limits?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., total HAP emissions measured as total hydrocarbon (THC) are reduced by 95 percent or greater for existing sources, or 97 percent or greater for new or reconstructed sources, or that outlet THC emissions...

  6. 40 CFR 63.3491 - What are my options for meeting the emission limits?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., total HAP emissions measured as total hydrocarbon (THC) are reduced by 95 percent or greater for existing sources, or 97 percent or greater for new or reconstructed sources, or that outlet THC emissions...

  7. 40 CFR 63.3491 - What are my options for meeting the emission limits?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., total HAP emissions measured as total hydrocarbon (THC) are reduced by 95 percent or greater for existing sources, or 97 percent or greater for new or reconstructed sources, or that outlet THC emissions...

  8. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  9. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  10. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  11. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  12. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  13. 40 CFR 63.3556 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure.../outlet Concentration Option § 63.3556 How do I establish the emission capture system and add-on control...

  14. 40 CFR 63.3556 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure.../outlet Concentration Option § 63.3556 How do I establish the emission capture system and add-on control...

  15. 40 CFR 63.3556 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... Control Efficiency/outlet Concentration Option § 63.3556 How do I establish the emission capture system...

  16. Tobacco outlet density and converted versus native non-daily cigarette use in a national US sample.

    PubMed

    Kirchner, Thomas R; Anesetti-Rothermel, Andrew; Bennett, Morgane; Gao, Hong; Carlos, Heather; Scheuermann, Taneisha S; Reitzel, Lorraine R; Ahluwalia, Jasjit S

    2017-01-01

    Investigate whether non-daily smokers' (NDS) cigarette price and purchase preferences, recent cessation attempts, and current intentions to quit are associated with the density of the retail cigarette product landscape surrounding their residential address. Cross-sectional assessment of N=904 converted NDS (CNDS). who previously smoked every day, and N=297 native NDS (NNDS) who only smoked non-daily, drawn from a national panel. Kernel density estimation was used to generate a nationwide probability surface of tobacco outlets linked to participants' residential ZIP code. Hierarchically nested log-linear models were compared to evaluate associations between outlet density, non-daily use patterns, price sensitivity and quit intentions. Overall, NDS in ZIP codes with greater outlet density were less likely than NDS in ZIP codes with lower outlet density to hold 6-month quit intentions when they also reported that price affected use patterns (G 2 =66.1, p<0.001) and purchase locations (G 2 =85.2, p<0.001). CNDS were more likely than NNDS to reside in ZIP codes with higher outlet density (G 2 =322.0, p<0.001). Compared with CNDS in ZIP codes with lower outlet density, CNDS in high-density ZIP codes were more likely to report that price influenced the amount they smoke (G 2 =43.9, p<0.001), and were more likely to look for better prices (G 2 =59.3, p<0.001). NDS residing in high-density ZIP codes were not more likely to report that price affected their cigarette brand choice compared with those in ZIP codes with lower density. This paper provides initial evidence that the point-of-sale cigarette environment may be differentially associated with the maintenance of CNDS versus NNDS patterns. Future research should investigate how tobacco control efforts can be optimised to both promote cessation and curb the rising tide of non-daily smoking in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Implications of Natural Occlusion of Ventilated Racks on Ammonia and Sanitation Practices

    PubMed Central

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-01-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague–Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded. PMID:24602544

  18. Implications of natural occlusion of ventilated racks on ammonia and sanitation practices.

    PubMed

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-03-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague-Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded.

  19. Alcohol outlet characteristics and alcohol sales to youth: results of alcohol purchase surveys in 45 Oregon communities.

    PubMed

    Paschall, Mallie J; Grube, Joel W; Black, Carol; Flewelling, Robert L; Ringwalt, Christopher L; Biglan, Anthony

    2007-06-01

    Reducing youth access to commercial sources of alcohol is recognized as a necessary component of a comprehensive strategy to reduce underage drinking and alcohol-related problems. However, research on policy-relevant factors that may influence the commercial availability of alcohol to youth is limited. The present study examines characteristics of off-premise alcohol outlets that may affect alcohol sales to youth. Random alcohol purchase surveys (N = 385) were conducted in 45 Oregon communities in 2005. Underage-looking decoys who were 21 years old but did not carry IDs were able to purchase alcohol at 34% of the outlets approached. Purchase rates were highest at convenience (38%) and grocery (36%) stores but were relatively low (14%) at other types of outlets (e.g., liquor and drug stores). Alcohol purchases were less likely at stores that were participating in the Oregon Liquor Control Commission's Responsible Vendor Program (RVP), when sales clerks asked the decoys for their IDs, and at stores with a posted underage alcohol sale warning sign. Alcohol purchases were also inversely related to the number of sales clerks present in a store, but were not related to sales clerks' age and gender. Findings of this study suggest that more frequent compliance checks by law enforcement agents should target convenience and grocery stores, and owners of off-premise outlets should require training of all sales clerks to ensure reliable checks of young-looking patron IDs, and should post underage alcohol sales warning signs in clear view of patrons.

  20. Safety considerations in testing a fuel-rich aeropropulsion gas generator

    NASA Technical Reports Server (NTRS)

    Rollbuhler, R. James; Hulligan, David D.

    1991-01-01

    A catalyst containing reactor is being tested using a fuel-rich mixture of Jet A fuel and hot input air. The reactor product is a gaseous fuel that can be utilized in aeropropulsion gas turbine engines. Because the catalyst material is susceptible to damage from high temperature conditions, fuel-rich operating conditions are attained by introducing the fuel first into an inert gas stream in the reactor and then displacing the inert gas with reaction air. Once a desired fuel-to-air ratio is attained, only limited time is allowed for a catalyst induced reaction to occur; otherwise the inert gas is substituted for the air and the fuel flow is terminated. Because there presently is not a gas turbine combustor in which to burn the reactor product gas, the gas is combusted at the outlet of the test facility flare stack. This technique in operations has worked successfully in over 200 tests.

  1. Effect of Inlet and Outlet Flow Conditions on Natural Gas Parameters in Supersonic Separation Process

    PubMed Central

    Yang, Yan; Wen, Chuang; Wang, Shuli; Feng, Yuqing

    2014-01-01

    A supersonic separator has been introduced to remove water vapour from natural gas. The mechanisms of the upstream and downstream influences are not well understood for various flow conditions from the wellhead and the back pipelines. We used a computational model to investigate the effect of the inlet and outlet flow conditions on the supersonic separation process. We found that the shock wave was sensitive to the inlet or back pressure compared to the inlet temperature. The shock position shifted forward with a higher inlet or back pressure. It indicated that an increasing inlet pressure declined the pressure recovery capacity. Furthermore, the shock wave moved out of the diffuser when the ratio of the back pressure to the inlet one was greater than 0.75, in which the state of the low pressure and temperature was destroyed, resulting in the re-evaporation of the condensed liquids. Natural gas would be the subsonic flows in the whole supersonic separator, if the mass flow rate was less than the design value, and it could not reach the low pressure and temperature for the condensation and separation of the water vapor. These results suggested a guidance mechanism for natural gas supersonic separation in various flow conditions. PMID:25338207

  2. 14 CFR 25.1013 - Oil tanks.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... tank used with a turbine engine must have an expansion space of not less than 10 percent of the tank... must be arranged so that condensed water vapor that might freeze and obstruct the line cannot... operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine...

  3. 14 CFR 25.1013 - Oil tanks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... tank used with a turbine engine must have an expansion space of not less than 10 percent of the tank... must be arranged so that condensed water vapor that might freeze and obstruct the line cannot... operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine...

  4. 14 CFR 25.1013 - Oil tanks.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... tank used with a turbine engine must have an expansion space of not less than 10 percent of the tank... must be arranged so that condensed water vapor that might freeze and obstruct the line cannot... operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine...

  5. 14 CFR 25.1013 - Oil tanks.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... tank used with a turbine engine must have an expansion space of not less than 10 percent of the tank... must be arranged so that condensed water vapor that might freeze and obstruct the line cannot... operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine...

  6. 14 CFR 25.1013 - Oil tanks.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... tank used with a turbine engine must have an expansion space of not less than 10 percent of the tank... must be arranged so that condensed water vapor that might freeze and obstruct the line cannot... operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine...

  7. Heat pump water heater and storage tank assembly

    DOEpatents

    Dieckmann, John T.; Nowicki, Brian J.; Teagan, W. Peter; Zogg, Robert

    1999-09-07

    A water heater and storage tank assembly comprises a housing defining a chamber, an inlet for admitting cold water to the chamber, and an outlet for permitting flow of hot water from the chamber. A compressor is mounted on the housing and is removed from the chamber. A condenser comprises a tube adapted to receive refrigerant from the compressor, and winding around the chamber to impart heat to water in the chamber. An evaporator is mounted on the housing and removed from the chamber, the evaporator being adapted to receive refrigerant from the condenser and to discharge refrigerant to conduits in communication with the compressor. An electric resistance element extends into the chamber, and a thermostat is disposed in the chamber and is operative to sense water temperature and to actuate the resistance element upon the water temperature dropping to a selected level. The assembly includes a first connection at an external end of the inlet, a second connection at an external end of the outlet, and a third connection for connecting the resistance element, compressor and evaporator to an electrical power source.

  8. Quarterly progress report on Blowdown Heat Transfer Separate-Effects Program for January--March 1978. [PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, D.G.; Bohanan, R.E.; Clark, D.L.

    1978-06-30

    The Thermal-Hydraulic Test Facility (THTF) has completed 24 powered rod blowdowns through Mar. 9, 1978. Of these blowdowns, 5 were completed with all 49 rods powered, 2 were completed with 2 inactive rods, and 13 were completed with 4 inactive rods. Initial system pressure was approximately 15.5 MPa (approximately 2250 psi), test section inlet temperature was approximately 559/sup 0/K (approximately 547/sup 0/F), and break area was equivalent to a 200 percent break with the total area usually split between inlet and outlet in the ratio 0.40 : 0.60. Heater rod power was 80, 100, or 122 kW/rod, and the testmore » section outlet temperature was 607/sup 0/K (632/sup 0/F), 598/sup 0/K (617/sup 0/F), or 589/sup 0/K (600/sup 0/F). Mean time to CHF varied from 0.7 to 1.4 sec, with delayed CHF of approximately 2.5 sec occurring in the upper half of the bundle in some tests.« less

  9. Syngas production by high temperature steam/CO2 coelectrolysis using solid oxide electrolysis cells.

    PubMed

    Chen, Xinbing; Guan, Chengzhi; Xiao, Guoping; Du, Xianlong; Wang, Jian-Qiang

    2015-01-01

    High temperature (HT) steam/CO2 coelectrolysis with solid oxide electrolysis cells (SOECs) using the electricity and heat generated from clean energies is an important alternative for syngas production without fossil fuel consumption and greenhouse gas emissions. Herein, reaction characteristics and the outlet syngas composition of HT steam/CO2 coelectrolysis under different operating conditions, including distinct inlet gas compositions and electrolysis current densities, are systematically studied at 800 °C using commercially available SOECs. The HT coelectrolysis process, which has comparable performance to HT steam electrolysis, is more active than the HT CO2 electrolysis process, indicating the important contribution of the reverse water-gas shift reaction in the formation of CO. The outlet syngas composition from HT steam/CO2 coelectrolysis is very sensitive to the operating conditions, indicating the feasibility of controlling the syngas composition by varying these conditions. Maximum steam and CO2 utilizations of 77% and 76% are achieved at 1.0 A cm(-2) with an inlet gas composition of 20% H2/40% steam/40% CO2.

  10. Acceleration of high-pressure-ratio single-spool turbojet engine as determined from component performance characteristics I : effect of air bleed at compressor outlet

    NASA Technical Reports Server (NTRS)

    Rebeske, John J , Jr; Rohlik, Harold E

    1953-01-01

    An analytical investigation was made to determine from component performance characteristics the effect of air bleed at the compressor outlet on the acceleration characteristics of a typical high-pressure-ratio single-spool turbojet engine. Consideration of several operating lines on the compressor performance map with two turbine-inlet temperatures showed that for a minimum acceleration time the turbine-inlet temperature should be the maximum allowable, and the operating line on the compressor map should be as close to the surge region as possible throughout the speed range. Operation along such a line would require a continuously varying bleed area. A relatively simple two-step area bleed gives only a small increase in acceleration time over a corresponding variable-area bleed. For the modes of operation considered, over 84 percent of the total acceleration time was required to accelerate through the low-speed range ; therefore, better low-speed compressor performance (higher pressure ratios and efficiencies) would give a significant reduction in acceleration time.

  11. Calculation of gas temperature at the outlet of the combustion chamber and in the air-gas channel of a gas-turbine unit by data of acceptance tests in accordance with ISO

    NASA Astrophysics Data System (ADS)

    Kostyuk, A. G.; Karpunin, A. P.

    2016-01-01

    This article describes a high accuracy method enabling performance of the calculation of real values of the initial temperature of a gas turbine unit (GTU), i.e., the gas temperature at the outlet of the combustion chamber, in a situation where manufacturers do not disclose this information. The features of the definition of the initial temperature of the GTU according to ISO standards were analyzed. It is noted that the true temperatures for high-temperature GTUs is significantly higher than values determined according to ISO standards. A computational procedure for the determination of gas temperatures in the air-gas channel of the gas turbine and cooling air consumptions over blade rims is proposed. As starting equations, the heat balance equation and the flow mixing equation for the combustion chamber are assumed. Results of acceptance GTU tests according to ISO standards and statistical dependencies of required cooling air consumptions on the gas temperature and the blade metal are also used for calculations. An example of the calculation is given for one of the units. Using a developed computer program, the temperatures in the air-gas channel of certain GTUs are calculated, taking into account their design features. These calculations are performed on the previously published procedure for the detailed calculation of the cooled gas turbine subject to additional losses arising because of the presence of the cooling system. The accuracy of calculations by the computer program is confirmed by conducting verification calculations for the GTU of the Mitsubishi Comp. and comparing results with published data of the company. Calculation data for temperatures were compared with the experimental data and the characteristics of the GTU, and the error of the proposed method is estimated.

  12. Nuclear reactor I

    DOEpatents

    Ference, Edward W.; Houtman, John L.; Waldby, Robert N.

    1977-01-01

    A nuclear reactor, particularly a liquid-metal breeder reactor whose upper internals include provision for channeling the liquid metal flowing from the core-component assemblies to the outlet plenum in vertical paths in direction generally along the direction of the respective assemblies. The metal is channeled by chimneys, each secured to, and extending from, a grid through whose openings the metal emitted by a plurality of core-component assemblies encompassed by the grid flows. To reduce the stresses resulting from structural interaction, or the transmissive of thermal strains due to large temperature differences in the liquid metal emitted from neighboring core-component assemblies, throughout the chimneys and the other components of the upper internals, the grids and the chimneys are supported from the heat plate and the core barrel by support columns (double portal support) which are secured to the head plate at the top and to a member, which supports the grids and is keyed to the core barrel, at the bottom. In addition to being restrained from lateral flow by the chimneys, the liquid metal is also restrained from flowing laterally by a peripheral seal around the top of the core. This seal limits the flow rate of liquid metal, which may be sharply cooled during a scram, to the outlet nozzles. The chimneys and the grids are formed of a highly-refractory, high corrosion-resistant nickel-chromium-iron alloy which can withstand the stresses produced by temperature differences in the liquid metal. The chimneys are supported by pairs of plates, each pair held together by hollow stubs coaxial with, and encircling, the chimneys. The plates and stubs are a welded structure but, in the interest of economy, are composed of stainless steel which is not weld compatible with the refractory metal. The chimneys and stubs are secured together by shells of another nickel-chromium-iron alloy which is weld compatible with, and is welded to, the stubs and has about the same coefficient of expansion as the highly-refractory, high corrosion-resistant alloy.

  13. 40 CFR 63.1188 - What performance test requirements must I meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance Tests and Methods § 63.1188 What performance test requirements must I meet? You must meet the... numerical emission limit for PM, CO, or formaldehyde, or at the inlet and outlet of the control device if...

  14. Hinge-line Migration of Petermann Gletscher, North Greenland, Detected Using Satellite Radar Interferometry

    NASA Technical Reports Server (NTRS)

    Rignot, Eric

    1998-01-01

    The synthetic-aperture radar interferometry technique is used to detect the migration of the limit of tidal flexing, or hinge line, of the floating ice tongue of Petermann Gletscher, a major outlet glacier of north Greenland.

  15. On the nature of real and perceived bias in the mainstream media.

    PubMed

    Elejalde, Erick; Ferres, Leo; Herder, Eelco

    2018-01-01

    News consumers expect news outlets to be objective and balanced in their reports of events and opinions. However, there is a growing body of evidence of bias in the media caused by underlying political and socio-economic viewpoints. Previous studies have tried to classify the partiality of the media, but there is little work on quantifying it, and less still on the nature of this partiality. The vast amount of content published in social media enables us to quantify the inclination of the press to pre-defined sides of the socio-political spectrum. To describe such tendencies, we use tweets to automatically compute a news outlet's political and socio-economic orientation. Results show that the media have a measurable bias, and illustrate this by showing the favoritism of Chilean media for the ruling political parties in the country. This favoritism becomes clearer as we empirically observe a shift in the position of the mass media when there is a change in government. Even though relative differences in bias between news outlets can be observed, public awareness of the bias of the media landscape as a whole appears to be limited by the political space defined by the news that we receive as a population. We found that the nature of the bias is reflected in the vocabulary used and the entities mentioned by different news outlets. A survey conducted among news consumers confirms that media bias has an impact on the coverage of controversial topics and that this is perceivable by the general audience. Having a more accurate method to measure and characterize media bias will help readers position outlets in the socio-economic landscape, even when a (sometimes opposite) self-declared position is stated. This will empower readers to better reflect on the content provided by their news outlets of choice.

  16. The Joule-Thomson coefficient as a criterion for efficient operating conditions in supercritical fluid chromatography.

    PubMed

    Poe, Donald P; Helmueller, Shawn; Kobany, Stephanie; Feldhacker, Hannah; Kaczmarski, Krzysztof

    2017-01-27

    When an SFC column is operated in a traditional oven with forced air at low pressures near the critical temperature, severe efficiency losses can occur. The mobile phase cools as it expands along the column, forming axial and radial temperature gradients. In this study we present a simple model based on a virtual fluid to predict the conditions which lead to the onset of efficiency loss. The model shows that the Joule-Thomson coefficient is an important factor leading to efficiency loss in packed columns under forced air conditions. The model was tested experimentally for elution of n-alkylbenzenes on 250×4.6-mm ID columns packed with 5-μm Luna-C18 (fully porous) and Kinetex-C18 (superficially porous) particles at optimum flow rates in a forced air oven at 20-80°C and outlet pressures from 90 to 250bar, with CO 2 mobile phase containing 5, 10 and 20% methanol (v/v). For simplicity, we used a formal J-T coefficient corresponding to the inlet temperature and the outlet pressure to characterize the chromatographic conditions. For 5% methanol, there was no significant loss of efficiency for elution of n-octadecylbenzene as long as the formal J-T coefficient was less than 0.11K/bar for Luna or 0.15K/bar for Kinetex, with minimum reduced plate heights equal to 1.82 and 1.55, respectively, at an average apparent retention factor of approximately 4.0 for both columns. The Kinetex column provided superior efficiency in general, and at 10-20bar lower outlet pressures relative to the Luna column due to the higher thermal conductivity of the packing. Results for 10 and 20% methanol showed similar trends but were less predictable. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Hydrodynamic performance and heat generation by centrifugal pumps.

    PubMed

    Ganushchak, Y; van Marken Lichtenbelt, W; van der Nagel, T; de Jong, D S

    2006-11-01

    For over a century, centrifugal pumps (CP) have been used in various applications, from large industrial pumps to flow pumps for aquariums. However, the use of CP as blood pumps has a rather short history. Consequently, the hydraulic performance data for a blood CP are limited. The aim of our investigation was to study the hydraulic performance and the heat generation of three commercially available CP: Bio-Medicus Bio-Pump BP80 (Medtronic), Rotaflow (Jostra Medizintechnik), and DeltaStream DP2 (MEDOS Medizintechnik AQ). The study was performed using a circuit primed with a water-glycerin mixture with a dynamic viscosity of 0.00272 pa/s. Pressure-flow curves were obtained by a stepwise stagnation of the pump outlet or inlet. The temperature changes were observed using ThermaCAM SC2000 (Flir Systems). The pumps' performance in close to clinical conditions ('operating region') was analysed in this report. The 'operating region' in the case of the BP80 is positioned around the pressure-flow curve at a pump speed of 3000 rpm. In the case of the Rotaflow, the 'operating region' was between the pump pressure-flow curves at a speed of 3000 and 4000 rpm, and the DP2 was found between 7000 and 8000 rpm. The standard deviation of mean pressure through the pump was used to characterise the stability of the pump. In experiments with outlet stagnation, the BP80 demonstrated high negative association between flow and pressure variability (r = -0.68, p < 0.001). In experiments with the DP2, this association was positive (r = 0.68, p < 0.001). All pumps demonstrated significantly higher variability of pressure in experiments with inlet stagnation in comparison to the experiments with outlet stagnation. The rise of relative temperature in the inlet of a pump was closely related to the flow rate. The heating of fluid was more pronounced in the 'zero-flow' mode, especially in experiments with inlet stagnation. In summary, (1) the 'zero-flow' regime, which is described in the manuals of some commercially-available pumps, is the use of the pump outside the allowable operating region. It is potentially dangerous and should, therefore, never be used in clinical settings. (2) Using centrifugal pumps for kinetic-assisted venous return can only be performed safely when the negative pressure at the inlet of the pump is monitored continuously. The maximum allowable negative pressure has to be defined for each type of pump, and must be based on pump performance.

  18. Hydrological response and thermal effect of karst springs linked to aquifer geometry and recharge processes

    NASA Astrophysics Data System (ADS)

    Luo, Mingming; Chen, Zhihua; Zhou, Hong; Zhang, Liang; Han, Zhaofeng

    2018-03-01

    To be better understand the hydrological and thermal behavior of karst systems in South China, seasonal variations in flow, hydrochemistry and stable isotope ratios of five karst springs were used to delineate flow paths and recharge processes, and to interpret their thermal response. Isotopic data suggest that mean recharge elevations are 200-820 m above spring outlets. Springs that originate from high elevations have lower NO3 - concentrations than those originating from lower areas that have more agricultural activity. Measured Sr2+ concentrations reflect the strontium contents of the host carbonate aquifer and help delineate the spring catchment's saturated zone. Seasonal variations of NO3 - and Sr2+ concentrations are inversely correlated, because the former correlates with event water and the latter with baseflow. The mean annual water temperatures of springs were only slightly lower than the local mean annual surface temperature at the outlet elevations. These mean spring temperatures suggest a vertical gradient of 6 °C/vertical km, which resembles the adiabatic lapse rate of the Earth's stable atmosphere. Seasonal temperature variations in the springs are in phase with surface air temperatures, except for Heilongquan (HLQ) spring. Event-scale variations of thermal response are dramatically controlled by the circulation depth of karst systems, which determines the effectiveness of heat exchange. HLQ spring undergoes the deepest circulation depth of 820 m, and its thermal responses are determined by the thermally effective regulation processes at higher elevations and the mixing processes associated with thermally ineffective responses at lower elevations.

  19. The influence of using heat storage with PCM on inlet and outlet temperatures in substation in DHS

    NASA Astrophysics Data System (ADS)

    Nogaj, Kinga; Turski, Michał; Sekret, Robert

    2017-11-01

    The main objective of this article is to indicate the direction of development of new generation heating systems that use phase change materials, and the important criteria needed when choosing a phase change material. The work contains a detailed classification of materials using the latent heat of organic and inorganic PCM. This references the technical possibilities of existing heat storage technologies. A specific objective was adopted to determine the effect of using heat storage with PCM on inlet and outlet temperatures in substation in district heating systems. The scope of the study included determining the parameters of the heat distribution network as a function of an outdoor air temperature within the range of -20°C to + 12°C. The object of analysis was chosen to be the heating system parameters: supply 120°C and return 60°C. It is located on the surface of 160km2, and supplies heat to 240,000 residents. The total length of the district heating network is 170 km. Based on the study, it was found that the most advantageous material that accumulates heat depends on the return temperature in the heating network. For the above analyzed case, the return temperature was in the range of 46°C to 57°C. The analysis showed that the most preferred materials using heat of phase change, have possible applications in heating networks and received a return temperature including salt hydrates, such as MgSO4·7H2O and Na2S2O3·5H2. The introduction of stored heat for the district heating system with the phase change material in the form of salt hydrates, allows the return temperature in the district heating to remain at temperatures compatible with the adopted regulatory table for temperatures outside the standard heating season.

  20. Spray-dry desulfurization of flue gas from heavy oil combustion.

    PubMed

    Scala, Fabrizio; Lancia, Amedeo; Nigro, Roberto; Volpicelli, Gennaro

    2005-01-01

    An experimental investigation on sulfur dioxide removal in a pilot-scale spray dryer from the flue gas generated by combustion of low-sulfur (S) heavy oil is reported. A limewater slurry was sprayed through an ultrasonic two-fluid atomizer in the spray-dry chamber, and the spent sorbent was collected downstream in a pulse-jet baghouse together with fly ash. Flue gas was sampled at different points to measure the desulfurization efficiency after both the spray-dry chamber and the baghouse. Parametric tests were performed to study the effect of the following variables: gas inlet temperature, difference between gas outlet temperature and adiabatic saturation temperature, lime-to-S ratio, and average size of lime particles in the slurry. Results indicated that spray drying is an effective technology for the desulfurization of low-S fuel oil flue gas, provided operating conditions are chosen carefully. In particular, the lowest gas inlet and outlet temperatures compatible with baghouse operation should be selected, as should a sufficiently high lime-to-S ratio. The attainment of a small lime particle size in the slurry is critical for obtaining a high desulfurization efficiency. A previously presented spray-dry flue gas desulfurization model was used to simulate the pilot-scale desulfurization tests, to check the ability of the model to predict the S capture data and its usefulness as a design tool, minimizing the need for pilot-scale experimentation. Comparison between model and experimental results was fairly good for the whole range of calcium/S ratios considered.

  1. Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia

    PubMed Central

    Pruneau, Denise; Dorval, Josée; Thibault, Louis; Fisette, Jean-François; Bédard, Suzanne K.; Jacques, Annie; Beauregard, Patrice

    2016-01-01

    Background Blood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used. Methods Pressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested. Results We found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C. Conclusion To use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia. PMID:27711116

  2. Modular package for cooling a laser diode array

    DOEpatents

    Mundinger, David C.; Benett, William J.; Beach, Raymond J.

    1992-01-01

    A laser diode array is disclosed that includes a plurality of planar packages and active cooling. The laser diode array may be operated in a long duty cycle, or in continuous operation. A laser diode bar and a microchannel heat sink are thermally coupled in a compact, thin planar package having the laser diode bar located proximate to one edge. In an array, a number of such thin planar packages are secured together in a stacked configuration, in close proximity so that the laser diodes are spaced closely. The cooling means includes a microchannel heat sink that is attached proximate to the laser bar so that it absorbs heat generated by laser operation. To provide the coolant to the microchannels, each thin planar package comprises a thin inlet manifold and a thin outlet manifold connected to an inlet corridor and an outlet corridor. The inlet corridor comprises a hole extending through each of the packages in the array, and the outlet corridor comprises a hole extending through each of the packages in the array. The inlet and outlet corridors are connected to a conventional coolant circulation system. The laser diode array with active cooling has application as an optical pump for high power solid state lasers. Further, it can be incorporated in equipment such as communications devices and active sensors, and in military and space applications, and it can be useful in applications having space constraints and energy limitations.

  3. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  4. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  5. 16. DOWNSTREAM VIEW OF OUTLET STRUCTURE AND OUTLET CHANNEL, FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. DOWNSTREAM VIEW OF OUTLET STRUCTURE AND OUTLET CHANNEL, FROM WEST END OF EMBANKMENT. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  6. Influences of the neighbourhood food environment on adiposity of low-income preschool-aged children in Los Angeles County: a longitudinal study.

    PubMed

    Chaparro, M Pia; Whaley, Shannon E; Crespi, Catherine M; Koleilat, Maria; Nobari, Tabashir Z; Seto, Edmund; Wang, May C

    2014-11-01

    Few studies have examined the association between the food environment and adiposity in early childhood, a critical time for obesity prevention. The objective of this study was to examine the longitudinal association between neighbourhood food environment and adiposity among low-income preschool-aged children in a major metropolitan region in the USA. The study sample was 32 172 low-income preschool-aged children in Los Angeles County who had repeated weight and height measurements collected between ages 2 and 5 years through a federal nutrition assistance programme. We conducted multilevel longitudinal analyses to examine how spatial densities of healthy and unhealthy retail food outlets in the children's neighbourhoods were related to adiposity, as measured by weight-for-height z-score (WHZ), while controlling for neighbourhood-level income and education, family income, maternal education, and child's gender and race/ethnicity. Density of healthy food outlets was associated with mean WHZ at age 3 in a non-linear fashion, with mean WHZ being lowest for those exposed to approximately 0.7 healthy food outlets per square mile and higher for lesser and greater densities. Density of unhealthy food outlets was not associated with child WHZ. We found a non-linear relationship between WHZ and density of healthy food outlets. Research aiming to understand the sociobehavioural mechanisms by which the retail food environment influences early childhood obesity development is complex and must consider contextual settings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. 50. OUTLET WORKS: OUTLET STRUCTURE PLAN AND SECTIONS. Sheet ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. OUTLET WORKS: OUTLET STRUCTURE - PLAN AND SECTIONS. Sheet C-1, September, 1939. File no. SA 343/50. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  8. Freeboard reactions in fluidized coal combustion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walsh, P.M.; Dutta, A.; Beer, J.M.

    1984-05-11

    The objective of this study was to determine the contribution of freeboard combustion to overall fixed carbon conversion during atmospheric pressure fluidized bed combustion of Kentucky No. 9 high volatile bituminous coal. The progress of the O/sub 2//char reaction in the freeboard was inferred from O/sub 2/ profiles determined by gas sampling. The rates of O/sub 2/ consumption were in good agreement with the O/sub 2//char rate expression of Sergeant and Smith (1973), except at the lowest temperature investigated (964 K). The discrepancy in this case might be due to catalysis of the O/sub 2//char reaction by lime, since thismore » was the first run of the series. Extrapolation of the O/sub 2/ profile to the bed surface using the rate expression of Sergeant and Smith showed that approximately all of the fixed carbon conversion could be accounted for by freeboard combustion. A simple model is proposed in which devolatilization, fragmentation, attrition, and volatile combustion are limited to the bed; with combustion of the finely ground char occurring only in the freeboard. This model predicts O/sub 2/ at the combustor outlet within 60% of the measured values, except in the low temperature/high lime case.« less

  9. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., appendix A, to determine compliance with the organic HAP or TOC emission limit, you may use EPA Method 18... formaldehyde control efficiency as a surrogate for total organic HAP or TOC efficiency, or at the outlet of a...

  10. Barriers to prostate cancer prevention and community recommended health education strategies in an urban African American community in Jackson, Mississippi.

    PubMed

    Ekúndayò, Olúgbémiga T; Tataw, David B

    2013-01-01

    This article describes the use of survey research in collaboration with the African American urban community of Georgetown, Jackson, Mississippi to identify and understand prostate cancer knowledge, resource utilization, and health education strategies considered most effective in reaching the community with prostate cancer prevention messages. The study revealed profound needs in disease identification and resources awareness and utilization. Barriers to utilization were identified by participants to include lack of self-efficacy, low self-esteem, lack of trust in the health care system, limited knowledge of prostate pathology, and limited ability to pay. Participants' recommended strategies for reaching the community with prostate cancer education include traditional and nontraditional strategies. The list of recommendations exclude modern-day outlets such as handheld devices, Twitter, Facebook, blogs, wikis, and other Internet-based outlets. The findings provide a road map for program development and an intervention research agenda custom-tailored to the Georgetown community of Jackson, Mississippi.

  11. 21. AERIAL VIEW OF THE OUTLET STRUCTURE AND OUTLET CHANNEL, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. AERIAL VIEW OF THE OUTLET STRUCTURE AND OUTLET CHANNEL, LOOKING UPSTREAM.... Volume XVII, No. 11, December 26, 1939. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  12. 49 CFR 173.427 - Transport requirements for low specific activity (LSA) Class 7 (radioactive) materials and...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... subchapter) cargo tank motor vehicles. Bottom outlets are not authorized. Trailer-on-flat-car service is not... conveyances 1. LSA-I No limit. 2. LSA-II and LSA-III; Non-combustible solids No limit. 3. LSA-II and LSA-III; Combustible solids and all liquids and gases 100 A2 4. SCO 100 A2 Table 6—Industrial Package Integrity...

  13. 49 CFR 173.427 - Transport requirements for low specific activity (LSA) Class 7 (radioactive) materials and...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... subchapter) cargo tank motor vehicles. Bottom outlets are not authorized. Trailer-on-flat-car service is not... conveyances 1. LSA-I No limit. 2. LSA-II and LSA-III; Non-combustible solids No limit. 3. LSA-II and LSA-III; Combustible solids and all liquids and gases 100 A2 4. SCO 100 A2 Table 6—Industrial Package Integrity...

  14. Effect of the NACA Injection Impeller on the Mixture Distribution of a Double-row Radial Aircraft Engine

    NASA Technical Reports Server (NTRS)

    Marble, Frank E.; Ritter, William K.; Miller, Mahlon A.

    1946-01-01

    For the normal range of engine power the impeller provided marked improvement over the standard spray-bar injection system. Mixture distribution at cruising was excellent, maximum cylinder temperatures were reduced about 30 degrees F, and general temperature distribution was improved. The uniform mixture distribution restored the normal response of cylinder temperature to mixture enrichment and it reduced the possibility of carburetor icing, while no serious loss in supercharger pressure rise resulted from injection of fuel near the impeller outlet. The injection impeller also furnished a convenient means of adding water to the charge mixture for internal cooling.

  15. Changes in the Mass Balance of the Greenland Ice Sheet in a Warming Climate During 2003-2009

    NASA Technical Reports Server (NTRS)

    Zwally, H. Jay; Luthcke, Scott

    2010-01-01

    Mass changes of the Greenland ice sheet (GIS) derived from ICESat and GRACE data both show that the net mass loss from GIS during 2003-2009 is about 175 Gt/year, which contributes 0.5mm/yr global sea-level rise. The rate of mass loss has increased significantly since the 1990's when the GIS was close to mass balance. Even though the GIS was close to mass balance during the 1990's, it was already showing characteristics of responding to8 warmer climate, specifically thinning at the margins and thickening inland at higher elevations. During 2003-2009, increased ice thinning due to increases in melting and acceleration of outlet glaciers began to strongly exceed the inland thickening from increases in accumulation. Over the entire GIS, the mass loss between the two periods, from increased melting and ice dynamics, increased by about 190 Gt/year while the mass gain, from increased precipitation and accumulation, increased by only about 15Gt/year. These ice changes occurred during a time when the temperature on GIS changed at rate of about 2K/decade. The distribution of elevation and mass changes derived from ICESat have high spatial resolution showing details over outlet glaciers, by drainage systems, and by elevation. However, information on the seasonal cycle of changes from ICESat data is limited, because the ICESat lasers were only operated during two to three campaigns per year of about 35 days duration each. In contrast, the temporal resolution of GRACE data, provided by the continuous data collection, is much better showing details of the seasonal cycle and the inter-annual variability. The differing sensitivity of the ICESat altimetry and the GRACE gravity methods to motion of the underlying bedrock from glacial isostatic adjustment (GIA) is used to evaluate the GIA corrections provided by models. The two data types are also combined to make estimates of the partitioning of the mass gains and losses among accumulation, melting, and ice discharge from outlet glaciers.

  16. Investigation of alternative layouts for the supercritical carbon dioxide Brayton cycle for a sodium-cooled fast reactor.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moisseytsev, A.; Sienicki, J. J.

    2009-07-01

    Analyses of supercritical carbon dioxide (S-CO{sub 2}) Brayton cycle performance have largely settled on the recompression supercritical cycle (or Feher cycle) incorporating a flow split between the main compressor downstream of heat rejection, a recompressing compressor providing direct compression without heat rejection, and high and low temperature recuperators to raise the effectiveness of recuperation and the cycle efficiency. Alternative cycle layouts have been previously examined by Angelino (Politecnico, Milan), by MIT (Dostal, Hejzlar, and Driscoll), and possibly others but not for sodium-cooled fast reactors (SFRs) operating at relatively low core outlet temperature. Thus, the present authors could not be suremore » that the recompression cycle is an optimal arrangement for application to the SFR. To ensure that an advantageous alternative layout has not been overlooked, several alternative cycle layouts have been investigated for a S-CO{sub 2} Brayton cycle coupled to the Advanced Burner Test Reactor (ABTR) SFR preconceptual design having a 510 C core outlet temperature and a 470 C turbine inlet temperature to determine if they provide any benefit in cycle performance (e.g., enhanced cycle efficiency). No such benefits were identified, consistent with the previous examinations, such that attention was devoted to optimizing the recompression supercritical cycle. The effects of optimizing the cycle minimum temperature and pressure are investigated including minimum temperatures and/or pressures below the critical values. It is found that improvements in the cycle efficiency of 1% or greater relative to previous analyses which arbitrarily fixed the minimum temperature and pressure can be realized through an optimal choice of the combination of the minimum cycle temperature and pressure (e.g., for a fixed minimum temperature there is an optimal minimum pressure). However, this leads to a requirement for a larger cooler for heat rejection which may impact the tradeoff between efficiency and capital cost. In addition, for minimum temperatures below the critical temperature, a lower heat sink temperature is required the availability of which is dependent upon the climate at the specific plant site.« less

  17. Social disadvantage and exposure to lower priced alcohol in off-premise outlets.

    PubMed

    Morrison, Christopher; Ponicki, William R; Smith, Karen

    2015-07-01

    Greater concentrations of off-premise alcohol outlets are found in areas of social disadvantage, exposing disadvantaged populations to excess risk for problems such as assault, child abuse and intimate partner violence. This study examines whether the outlets to which they are exposed also sell cheaper alcohol, potentially further contributing to income-related health disparities. We conducted unobtrusive observations in 295 off-premise outlets in Melbourne, Australia, randomly selected using a spatial sample frame. In semi-logged linear regression models, we related the minimum purchase price for a 750 mL bottle of wine to a national index of socioeconomic advantage for the census areas in which the outlets were located. Other independent variables characterised outlet features (e.g. volume, chain management) and conditions of the local alcohol market (adjacent outlet characteristics, neighbourhood characteristics). A one decile increase in socioeconomic advantage was related to a 1.3% increase in logged price. Larger outlets, chains, outlets adjacent to chains, outlets in greater proximity to the nearest neighbouring outlet and those located in areas with more students also had cheaper alcohol. Not only are disadvantaged populations exposed to more outlets, the outlets to which they are exposed sell cheaper alcohol. This finding appears to be consistent with the spatial dynamics of typical retail markets. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  18. The association between the density of retail tobacco outlets, individual smoking status, neighbourhood socioeconomic status and school locations in New South Wales, Australia.

    PubMed

    Marashi-Pour, Sadaf; Cretikos, Michelle; Lyons, Claudine; Rose, Nick; Jalaludin, Bin; Smith, Joanne

    2015-01-01

    We explored the association between the density of tobacco outlets and neighbourhood socioeconomic status, and between neighbourhood tobacco outlet density and individual smoking status. We also investigated the density of tobacco outlets around primary and secondary schools in New South Wales (NSW). We calculated the mean density of retail tobacco outlets registered in NSW between 2009 and 2011, using kernel density estimation with an adaptive bandwidth. We used generalised ordered logistic regression model to explore the association between socioeconomic status and density of tobacco outlets. The association between neighbourhood tobacco outlet density and individuals' current smoking status was investigated using random-intercept generalised linear mixed models. We also calculated the median tobacco outlet density around NSW schools. More disadvantaged Census Collection Districts (CDs) were significantly more likely to have higher tobacco outlet densities. After adjusting for neighbourhood socioeconomic status and participants' age, sex, country of birth and Aboriginal status, neighbourhood mean tobacco outlet density was significantly and positively associated with individuals' smoking status. The median of tobacco outlet density around schools was significantly higher than the state median. Policymakers could consider exploring a range of strategies that target tobacco outlets in proximity to schools, in more disadvantaged neighbourhoods and in areas of existing high tobacco outlet density. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  19. The Moderating Role of Gender in the Relationship Between Tobacco Outlet Exposure and Tobacco Use Among African American Young Adults.

    PubMed

    Brown, Qiana; Milam, Adam J; Bowie, Janice V; Ialongo, Nicholas S; Gaskin, Darrell J; Furr-Holden, Debra

    2016-04-01

    Tobacco outlet exposure is a correlate of tobacco use with potential differences by gender that warrant attention. The aim of this study is to explore the moderating role of gender in the relationship between tobacco outlet exposure and past month tobacco use among African American young adults 21 to 24 years old. This cross-sectional study (n = 283) used geospatial methods to determine the number of tobacco outlets within walking distance (i.e., a quarter mile) of participants' homes and distance to the nearest outlet. Logistic regression models were used to test interactions between gender and tobacco outlet exposure (i.e., density and proximity). Tobacco outlets were classified based on whether or not they were licensed to sell tobacco only (TO outlets) or tobacco and alcohol (TA outlets). Neither density nor proximity was associated with past month tobacco use in the pooled models. However, gender modified the relationship between TO outlet density and tobacco use, and this relationship was significant only among women (OR = 1.02; p < 0.01; adjusted OR = 1.01; p < 0.05). This study underscores the importance of reducing tobacco outlet density in residential neighborhoods, especially TO outlets, as well as highlights potential gender differences in the relationship between tobacco outlet density and tobacco use.

  20. Audit of tobacco retail outlets in Hangzhou, China.

    PubMed

    Gong, Ting; Lv, Jun; Liu, Qingmin; Ren, Yanjun; Li, Liming; Kawachi, Ichiro

    2013-07-01

    To determine the prevalence of tobacco advertisements and warning messages at points of sale as well as to examine the density of tobacco retail outlets in neighbourhoods and around schools in Hangzhou, China. Tobacco retail outlets (n=1639) in all food and tobacco specialty stores were observed objectively by trained students. Tobacco advertisements and warning messages were assessed with an audit, and stores' addresses were recorded with Global Positioning System coordinates. The distances (1) between all pairs of tobacco retail outlets (2) between each tobacco retail outlet and 15 middle schools were calculated to assess the density of tobacco retail outlets in neighbourhoods and around schools. Among the 1639 tobacco retail outlets, <1% had 'no sales to minors' signs, 1.5% had tobacco warning messages, 28% had signs indicating tobacco sale and 12.4% had tobacco advertisements. For 48.7% of tobacco retail outlets, the nearest distances to other tobacco retail outlets were <50 m. For 80% of schools, there was at least one tobacco retail outlets within a 100 m radius. Tobacco advertisement in retail outlets is prevalent and the density of tobacco retail outlets is high in Hangzhou, China. Signs indicating 'no sales to minors' and tobacco warning signs are almost non-existent. These findings point to an urgent need for the enforcement of regulations on display of 'no sales to minors' and a new density standard for tobacco retail outlets based on protecting the public's health.

  1. Social Disadvantage and Exposure to Lower Priced Alcohol in Off-Premise Outlets

    PubMed Central

    Morrison, Christopher; Ponicki, William R; Smith, Karen

    2015-01-01

    Introduction and Aims Greater concentrations of off-premise alcohol outlets are found in areas of social disadvantage, exposing disadvantaged populations to excess risk for problems such as assault, child abuse and intimate partner violence. This study examines whether the outlets to which they are exposed also sell cheaper alcohol, potentially further contributing to income-related health disparities. Design and Methods We conducted unobtrusive observations in 295 off-premise outlets in Melbourne, Australia, randomly selected using a spatial sample frame. In semi-logged linear regression models we related the minimum purchase price for a 750ml bottle of wine to a national index of socio-economic advantage for the Census areas in which the outlets were located. Other independent variables characterised outlet features (e.g., volume, chain management) and conditions of the local alcohol market (adjacent outlet characteristics, neighbourhood characteristics). Results A one decile increase in socio-economic advantage was related to a 1.3% increase in logged price. Larger outlets, chains, outlets adjacent to chains, outlets in greater proximity to the nearest neighbouring outlet, those located in areas with more students also had cheaper alcohol. Discussion and Conclusions Not only are disadvantaged populations exposed to more outlets, the outlets to which they are exposed sell cheaper alcohol. This finding appears to be consistent with the spatial dynamics of typical retail markets. PMID:25808717

  2. Development of an Air Brayton solar receiver

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Various receiver configurations and operating conditions were examined. The interface requirements between the receiver/concentrator/power module were addressed. Production cost estimates were obtained to determine the cost of the receiver during the 1980 timeframe. A conceptual design of an air Brayton solar receiver is presented based on the results. The following design goals were established: (1)peak thermal input power - 85 KWt; (2)receiver outlet air temperature - 1500 F; (3)receiver inlet air temperature - 1050 F; (4)design mass flow rate - 0.533 lb/sec; and (5)design receiver inlet pressure - 36.75 psia.

  3. Modeling of Thermal Behavior of Raw Natural Gas Air Coolers

    NASA Astrophysics Data System (ADS)

    Scherbinin, S. V.; Prakhova, M. Yu; Krasnov, A. N.; Khoroshavina, E. A.

    2018-05-01

    When gas is being prepared for a long-range transportation, it passes through air cooling units (ACUs) after compressing; there, hot gas passing through finned tubes is cooled with air streams. ACU's mode of operation shall ensure a certain value of gas temperature at the ACU's outlet. At that, when cooling raw gas, temperature distribution along all the tubes shall be known to prevent local hydrate formation. The paper proposes a mathematical model allowing one to obtain a thermal field distribution inside the ACU and study influence of various factors onto it.

  4. Method of measuring heat influx of a cryogenic transfer system

    DOEpatents

    Niemann, Ralph C.; Zelipsky, Steven A.; Rezmer, Ronald R.; Smelser, Peter

    1981-01-01

    A method is provided for measuring the heat influx of a cryogenic transfer system. A gaseous phase of the cryogen used during normal operation of the system is passed through the system. The gaseous cryogen at the inlet to the system is tempered to duplicate the normal operating temperature of the system inlet. The temperature and mass flow rate of the gaseous cryogen is measured at the outlet of the system, and the heat capacity of the cryogen is determined. The heat influx of the system is then determined from known thermodynamic relationships.

  5. Gas dynamics of a supersonic radial jet. Part II

    NASA Astrophysics Data System (ADS)

    Kosarev, V. F.; Klinkov, S. V.; Zaikovskii, V. N.

    2016-05-01

    The paper presents the radial distributions of the pressure measured with a Pitot tube for the case of a radial jet with/without swirling of the input flow in the pre-chamber; the length of the supersonic part of the jet, dependency of the jet thickness as a function of the distance from the nozzle outlet, and approximating analytical formula for the jet thickness that generalizes the experimental data. Experimental data demonstrated that at the deposition distances lower than 4-6 gauges from the nozzle outlet, the solid particle velocity and temperature are almost uniform over the jet cross section. This means that the target surface can be allocated here without loss in coating quality and deposition coefficient. The maximal recommended distance where the deposition is still possible is the length of l s0 ~ 16 gauges.

  6. Analysis of heat recovery of diesel engine using intermediate working fluid

    NASA Astrophysics Data System (ADS)

    Jin, Lei; Zhang, Jiang; Tan, Gangfeng; Liu, Huaming

    2017-07-01

    The organic Rankine cycle (ORC) is an effective way to recovery the engine exhaust heat. The thermal stability of the evaporation system is significant for the stable operation of the ORC system. In this paper, the performance of the designed evaporation system which combines with the intermediate fluid for recovering the exhaust waste heat from a diesel engine is evaluated. The thermal characteristics of the target diesel engine exhaust gas are evaluated based on the experimental data firstly. Then, the mathematical model of the evaporation system is built based on the geometrical parameters and the specific working conditions of ORC. Finally, the heat transfer characteristics of the evaporation system are estimated corresponding to three typical operating conditions of the diesel engine. The result shows that the exhaust temperature at the evaporator outlet increases slightly with the engine speed and load. In the evaporator, the heat transfer coefficient of the Rankine working fluid is slightly larger than the intermediate fluid. However, the heat transfer coefficient of the intermediate fluid in the heat exchanger is larger than the exhaust side. The heat transfer areas of the evaporator in both the two-phase zone and the preheated zone change slightly along with the engine working condition while the heat transfer areas of the overheated zone has changed obviously. The maximum heat transfer rate occurs in the preheating zone while the minimum value occurs in the overheating zone. In addition, the Rankine working fluid temperature at the evaporator outlet is not sensitively affected by the torque and speed of the engine and the organic fluid flow is relatively stable. It is concluded that the intermediate fluid could effectively reduce the physical changes of Rankine working fluid in the evaporator outlet due to changes in engine operating conditions.

  7. Acquisition and correlation of cryogenic nitrogen mass flow data through a multiple orifice Joule-Thomson device

    NASA Astrophysics Data System (ADS)

    Papell, S. Stephen; Saiyed, Naseem H.; Nyland, Ted W.

    1990-05-01

    Liquid nitrogen mass flow rate, pressure drop, and temperature drop data were obtained for a series of multiple orifice Joule-Thomson devices, known as Visco Jets, over a wide range of flow resistance. The test rig used to acquire the data was designed to minimize heat transfer so that fluid expansion through the Visco Jets would be isenthalpic. The data include a range of fluid inlet pressures from 30 to 60 psia, fluid inlet temperatures from 118 to 164 R, outlet pressures from 2.8 to 55.8 psia, outlet temperatures from 117 to 162 R and flow rate from 0.04 to 4.0 lbm/hr of nitrogen. A flow rate equation supplied by the manufacturer was found to accurately predict single-phase (noncavitating) liquid nitrogen flow through the Visco Jets. For cavitating flow, the manufacturer's equation was found to be inaccurate. Greatly improved results were achieved with a modified version of the single-phase equation. The modification consists of a multiplication factor to the manufacturer's equation equal to one minus the downstream quality on an isenthalpic expansion of the fluid across the Visco Jet. For a range of flow resistances represented by Visco Jet Lohm ratings between 17,600 and 80,000, 100 percent of the single-phase data and 85 percent of the two-phase data fall within + or - 10 percent of predicted values.

  8. 40 CFR 63.323 - Test methods and monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air-perchloroethylene gas-vapor stream on the outlet side of the refrigerated condenser on a dry-to-dry machine, dryer, or reclaimer with a temperature sensor to determine if it is equal to or less than 7.2 °C (45 °F) before the end of the cool-down or drying cycle while the gas-vapor stream is flowing...

  9. 40 CFR 63.323 - Test methods and monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air-perchloroethylene gas-vapor stream on the outlet side of the refrigerated condenser on a dry-to-dry machine, dryer, or reclaimer with a temperature sensor to determine if it is equal to or less than 7.2 °C (45 °F) before the end of the cool-down or drying cycle while the gas-vapor stream is flowing...

  10. Fast quench reactor and method

    DOEpatents

    Detering, Brent A.; Donaldson, Alan D.; Fincke, James R.; Kong, Peter C.

    2002-01-01

    A fast quench reaction includes a reactor chamber having a high temperature heating means such as a plasma torch at its inlet and a restrictive convergent-divergent nozzle at its outlet end. Reactants are injected into the reactor chamber. The resulting heated gaseous stream is then rapidly cooled by passage through the nozzle. This "freezes" the desired end product(s) in the heated equilibrium reaction stage.

  11. Turbine Fuel Alternatives (Near Term)

    DTIC Science & Technology

    1989-10-01

    liability for the contents or use thereof. The United States Government does not endorse products or manufacturers. Trade or manufacturers’ names appear...VERSUS CORRECTED TURBINE OUTLET TEMPERATURE A-7 200, -T ’go-I 190 170- ETA oix 15X ETANOL ! ¶,0-1 1 20- S 110j 1. 001 9 0 I 7 0 10 zo 460 500 540 580

  12. Fast quench reactor and method

    DOEpatents

    Detering, Brent A.; Donaldson, Alan D.; Fincke, James R.; Kong, Peter C.

    1998-01-01

    A fast quench reaction includes a reactor chamber having a high temperature heating means such as a plasma torch at its inlet and a restrictive convergent-divergent nozzle at its outlet end. Reactants are injected into the reactor chamber. The resulting heated gaseous stream is then rapidly cooled by passage through the nozzle. This "freezes" the desired end product(s) in the heated equilibrium reaction stage.

  13. Fast quench reactor and method

    DOEpatents

    Detering, Brent A.; Donaldson, Alan D.; Fincke, James R.; Kong, Peter C.

    2002-09-24

    A fast quench reaction includes a reactor chamber having a high temperature heating means such as a plasma torch at its inlet and a restrictive convergent-divergent nozzle at its outlet end. Reactants are injected into the reactor chamber. The resulting heated gaseous stream is then rapidly cooled by passage through the nozzle. This "freezes" the desired end product(s) in the heated equilibrium reaction stage.

  14. Thermal Habitat Use and Evidence of Seasonal Migration by Rocky Mountain Tailed Frogs, Ascaphus montanus, in Montana

    Treesearch

    Susan B. Adams; Christopher A. Frissell

    2001-01-01

    All life stages of Rocky Mountain Tailed Frogs (Ascaphus montanus) occurred in a reach of Moore Creek. Montana, where water temperatures exceeded those previously reported for Ascaphus in the wild. However, relative density of Ascaphus in the wannest reach, immediately downstream of a lake outlet, was lower than in cooler reaches downstream. Although...

  15. Water-quality reconnaissance of Laguna Tortuguero, Vega Baja, Puerto Rico, March 1999-May 2000

    USGS Publications Warehouse

    Soler-Lopez, Luis; Guzman-Rios, Senen; Conde-Costas, Carlos

    2006-01-01

    The Laguna Tortuguero, a slightly saline to freshwater lagoon in north-central Puerto Rico, has a surface area of about 220 hectares and a mean depth of about 1.2 meters. As part of a water-quality reconnaissance, water samples were collected at about monthly and near bi-monthly intervals from March 1999 to May 2000 at four sites: three stations inside the lagoon and one station at the artificial outlet channel dredged in 1940, which connects the lagoon with the Atlantic Ocean. Physical characteristics that were determined from these water samples were pH, temperature, specific conductance, dissolved oxygen, dissolved oxygen saturation, and discharge at the outlet canal. Other water-quality constituents also were determined, including nitrogen and phosphorus species, organic carbon, chlorophyll a and b, plankton biomass, hardness, alkalinity as calcium carbonate, and major ions. Additionally, a diel study was conducted at three stations in the lagoon to obtain data on the diurnal variation of temperature, specific conductance, dissolved oxygen, and dissolved oxygen saturation. The data analysis indicates the water quality of Laguna Tortuguero complies with the Puerto Rico Environmental Quality Board standards and regulations.

  16. Shuttle active thermal control system development testing. Volume 3: Modular radiator system test data correlation with thermal model

    NASA Technical Reports Server (NTRS)

    Phillips, M. A.

    1973-01-01

    Results are presented of an analysis which compares the performance predictions of a thermal model of a multi-panel modular radiator system with thermal vacuum test data. Comparisons between measured and predicted individual panel outlet temperatures and pressure drops and system outlet temperatures have been made over the full range of heat loads, environments and plumbing arrangements expected for the shuttle radiators. Both two sided and one sided radiation have been included. The model predictions show excellent agreement with the test data for the maximum design conditions of high load and hot environment. Predictions under minimum design conditions of low load-cold environments indicate good agreement with the measured data, but evaluation of low load predictions should consider the possibility of parallel flow instabilities due to main system freezing. Performance predictions under intermediate conditions in which the majority of the flow is not in either the main or prime system are adequate although model improvements in this area may be desired. The primary modeling objective of providing an analytical technique for performance predictions of a multi-panel radiator system under the design conditions has been met.

  17. 24 CFR 3280.806 - Receptacle outlets.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., 125-volt, either single or duplex. (b) All 120 volt single phase, 15 and 20 ampere receptacle outlets... Receptacle outlets. (b) All 125-volt, single-phase, 15- and 20-ampere receptacle outlets installed outdoors... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Receptacle outlets. 3280.806...

  18. 5 CFR 591.217 - In which outlets does OPM collect prices?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... popular outlets in each survey area. OPM selects these outlets based on their proximity to the housing... that reflect sales volume. To the extent practical, OPM prices like items in the same types of outlets... surveys and select outlets based on the results of those surveys. ...

  19. Associations between proximity and density of local alcohol outlets and alcohol use among Scottish adolescents.

    PubMed

    Young, Robert; Macdonald, Laura; Ellaway, Anne

    2013-01-01

    Associations between different alcohol outcomes and outlet density measures vary between studies and may not be generalisable to adolescents. In a cross-sectional study of 979 15-year old Glaswegians, we investigated the association between alcohol outlet availability (outlet density and proximity), outlet type (on-premise vs. off-premise) and frequent (weekly) alcohol consumption. We adjusted for social background (gender, social class, family structure). Proximity and density of on-premise outlets were not associated with weekly drinking. However, adolescents living close (within 200 m) to an off-sales outlet were more likely to drink frequently (OR 1.97, p=0.004), as were adolescents living in areas with many nearby off-premises outlets (OR 1.60, p=0.016). Our findings suggest that certain alcohol behaviours (e.g. binge drinking) may be linked to the characteristics of alcohol outlets in the vicinity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Associations between proximity and density of local alcohol outlets and alcohol use among Scottish adolescents

    PubMed Central

    Young, Robert; Macdonald, Laura; Ellaway, Anne

    2013-01-01

    Associations between different alcohol outcomes and outlet density measures vary between studies and may not be generalisable to adolescents. In a cross-sectional study of 979 15-year old Glaswegians, we investigated the association between alcohol outlet availability (outlet density and proximity), outlet type (on-premise vs. off-premise) and frequent (weekly) alcohol consumption. We adjusted for social background (gender, social class, family structure). Proximity and density of on-premise outlets were not associated with weekly drinking. However, adolescents living close (within 200 m) to an off-sales outlet were more likely to drink frequently (OR 1.97, p=0.004), as were adolescents living in areas with many nearby off-premises outlets (OR 1.60, p=0.016). Our findings suggest that certain alcohol behaviours (e.g. binge drinking) may be linked to the characteristics of alcohol outlets in the vicinity. PMID:23220375

  1. Surface fatigue life and failure characteristics of EX-53, CBS 1000M, and AISI 9310 gear materials

    NASA Technical Reports Server (NTRS)

    Townsend, D. P.

    1985-01-01

    Spur gear endurance tests and rolling-element surface fatigue tests are conducted to investigate EX-53 and CBS 1000M steels for use as advanced application gear materials, to determine their endurance characteristics, and to compare the results with the standard AISI 9310 gear material. The gear pitch diameter is 8.89 cm (3.50 in). Gear test conditions are an oil inlet temperature of 320 K (116 F), an oil outlet temperature of 350 K (170 F), a maximum Hertz stress of 1.71 GPa (248 ksi), and a speed of 10,000 rpm. Bench-type rolling-element fatigue tests are conducted at ambient temperature with a bar specimen speed of 12,500 rpm and a maximum Hertz stress of 4.83 GPa (700 ksi). The EX-53 test gears have a surface fatigue life of twice that of the AISI 9310 spur gears. The CBS 1000M test gears have a surface fatigue life of more than twice that of the AISI 9310 spur gears. However, the CBS 1000M gears experience a 30-percent tooth fracture failure which limits its use as a gear material. The rolling-contact fatigue lines of RC bar specimens of EX-53 and ASISI 9310 are approximately equal. However, the CBS 1000M RC specimens have a surface fatigue life of about 50 percent that of the AISI 9310.

  2. Transient heat and mass transfer analysis in a porous ceria structure of a novel solar redox reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandran, RB; Bader, R; Lipinski, W

    2015-06-01

    Thermal transport processes are numerically analyzed for a porous ceria structure undergoing reduction in a novel redox reactor for solar thermochemical fuel production. The cylindrical reactor cavity is formed by an array of annular reactive elements comprising the porous ceria monolith integrated with gas inlet and outlet channels. Two configurations are considered, with the reactor cavity consisting of 10 and 20 reactive elements, respectively. Temperature dependent boundary heat fluxes are obtained on the irradiated cavity wall by solving for the surface radiative exchange using the net radiation method coupled to the heat and mass transfer model of the reactive element.more » Predicted oxygen production rates are in the range 40-60 mu mol s(-1) for the geometries considered. After an initial rise, the average temperature of the reactive element levels off at 1660 and 1680 K for the two geometries, respectively. For the chosen reduction reaction rate model, oxygen release continues after the temperature has leveled off which indicates that the oxygen release reaction is limited by chemical kinetics and/or mass transfer rather than by the heating rate. For a fixed total mass of ceria, the peak oxygen release rate is doubled for the cavity with 20 reactive elements due to lower local oxygen partial pressure. (C) 2015 Elsevier Masson SAS. All rights reserved.« less

  3. Options for legal measures to reduce acrylamide contents in the most relevant foods.

    PubMed

    Grob, K

    2007-01-01

    Options of taking measures for reducing acrylamide exposure are discussed from the viewpoint of health authorities. To achieve a significant effect on total exposure (without changing eating habits), a substantial reduction must be accomplished for the foods contributing most to total intake. Priority should be given to consumers with high exposure, which means that the average intake profile is not relevant, but high consumption of products with high acrylamide contents is relevant. Rather than introducing legal limits on acrylamide in the end-products, more basic factors determining acrylamide formation should be brought under control. Five measures are proposed. (1) For the preparation of fried and roasted products, potatoes low in reducing sugars should be made available to households and commercial outlets. (2) The content of reducing sugars in prefabricates for French fries should be limited. (3) Newly installed fryers should control the temperature profile from an initially high to a lower final value. (4) The use of ammonium carbonate in bakery products should be restricted. (5) There should be provisions to intervene if an acrylamide content clearly exceeds the level determined by good manufacturing practice and the products involved substantially contribute to total exposure in cases of high consumption.

  4. Simulation of the effects of the Devils Lake State Outlet on hydrodynamics and water quality in Lake Ashtabula, North Dakota, 2006-10

    USGS Publications Warehouse

    Galloway, Joel M.

    2011-01-01

    In 2010, a two-dimensional hydrodynamic and water-quality model (CE-QUAL-W2) of Lake Ashtabula, North Dakota, was developed by the U.S. Geological Survey in cooperation with the North Dakota State Water Commission to understand the dynamics of chemical constituents in the reservoir and to provide a tool for the management and operation of the Devils Lake State Outlet in meeting the water-quality standards downstream from Baldhill Dam. The Lake Ashtabula model was calibrated for hydrodynamics, sulfate concentrations, and total dissolved-solids concentrations to ambient conditions from June 2006 through June 2010. The calibrated model then was used to simulate four scenarios that represent various Devils Lake outlet options that have been considered for reducing the water levels in Devils Lake. Simulated water temperatures compared well with measured temperatures and differences varied spatially in Lake Ashtabula from June 2006 through June 2010. The absolute mean error ranged from 0.7 degrees Celsius to 1.0 degrees Celsius and the root mean square error ranged from 0.7 degrees Celsius to 1.1 degrees Celsius. Simulated sulfate concentrations compared well with measured concentrations in Lake Ashtabula. In general, simulated sulfate concentrations were slightly overpredicted with mean differences between simulated and measured sulfate concentrations ranging from -2 milligram per liter to 18 milligrams per liter. Differences between simulated and measured sulfate concentrations varied temporally in Lake Ashtabula from June 2006 through June 2010. In 2006, sulfate concentrations were overpredicted in the lower part of the reservoir and underpredicted in the upper part of the reservoir. Simulated total dissolved solids generally were greater than measured total dissolved-solids concentrations in Lake Ashtabula from June 2006 through June 2010. The mean difference between simulated and measured total dissolved-solids concentrations ranged from -3 milligrams per liter to 15 milligrams per liter, the absolute mean error ranged from 58 milligrams per liter to 100 milligrams per liter, and the root mean square error ranged from 73 milligrams per liter to 114 milligrams per liter. Simulated sulfate concentrations from four scenarios were compared to simulated ambient concentrations from June 2006 through June 2009. For scenario 1, the same location, outflow capacity, and sulfate concentration as the current (2010) Devils Lake State Outlet were assumed. The increased flow and sulfate concentration in scenario 1, beginning on May 31 and extending to October 31 each year, resulted in an increase in sulfate concentrations to greater than 450 milligrams per liter in the reservoir at site 7T (approximately the middle of the reservoir), starting July 5 in 2006, July 28 in 2007, and July 15 in 2008. Sulfate concentrations increased to greater than 450 milligrams per liter considerably later at site 1T (near the dam), starting October 8 in 2006, October 29 in 2007, and October 3 in 2008. For scenario 2, the same Devils Lake State Outlet sulfate concentration as scenario 1 was assumed, but the flow through the Devils Lake State Outlet was doubled, which resulted in a more rapid increase in sulfate concentrations in the lower part of the reservoir and slightly greater values at all four sites compared to scenario 1. Sulfate concentrations increased to greater than 450 milligrams per liter 61 days earlier in 2006, 67 days earlier in 2007, and 41 days earlier in 2008 at site 1T. For scenarios 3 and 4, possible increases in flow and concentration from the current outlet location (from the West Bay of Devils Lake) and from a proposed outlet from East Devils Lake were simulated. Conditions for scenario 3 resulted in a relatively rapid increase in sulfate concentrations in the reservoir, and concentrations were greater than 750 milligrams per liter in most years at all four sites. As expected, scenario 4 resulted in greater sulfate concentr

  5. Nitrate removal, communities of denitrifiers and adverse effects in different carbon substrates for use in denitrification beds

    PubMed Central

    Warneke, Sören; Schipper, Louis A.; Matiasek, Michael G.; Scow, Kate M.; Cameron, Stewart; Bruesewitz, Denise A.; McDonald, Ian R.

    2012-01-01

    Denitrification beds are containers filled with wood by-products that serve as a carbon and energy source to denitrifiers, which reduce nitrate ( NO3−) from point source discharges into non-reactive dinitrogen (N2) gas. This study investigates a range of alternative carbon sources and determines rates, mechanisms and factors controlling NO3− removal, denitrifying bacterial community, and the adverse effects of these substrates. Experimental barrels (0.2 m3) filled with either maize cobs, wheat straw, green waste, sawdust, pine woodchips or eucalyptus woodchips were incubated at 16.8 °C or 27.1 °C (outlet temperature), and received NO3− enriched water (14.38 mg N L−1 and 17.15 mg N L−1). After 2.5 years of incubation measurements were made of NO3−−N removal rates, in vitro denitrification rates (DR), factors limiting denitrification (carbon and nitrate availability, dissolved oxygen, temperature, pH, and concentrations of NO3−, nitrite and ammonia), copy number of nitrite reductase (nirS and nirK ) and nitrous oxide reductase (nosZ ) genes, and greenhouse gas production (dissolved nitrous oxide (N2O) and methane), and carbon (TOC) loss. Microbial denitrification was the main mechanism for NO3−−N removal. Nitrate–N removal rates ranged from 1.3 (pine woodchips) to 6.2 g N m−3 d−1 (maize cobs), and were predominantly limited by C availability and temperature (Q10 = 1.2) when NO3−−N outlet concentrations remained above 1 mg L−1. The NO3−−N removal rate did not depend directly on substrate type, but on the quantity of microbially available carbon, which differed between carbon sources. The abundance of denitrifying genes (nirS, nirK and nosZ ) was similar in replicate barrels under cold incubation, but varied substantially under warm incubation, and between substrates. Warm incubation enhanced growth of nirS containing bacteria and bacteria that lacked the nosZ gene, potentially explaining the greater N2O emission in warmer environments. Maize cob substrate had the highest NO3−−N removal rate, but adverse effects include TOC release, dissolved N2O release and substantial carbon consumption by non-denitrifiers. Wood-chips removed less than half of NO3− removed by maize cobs, but provided ideal conditions for denitrifying bacteria, and adverse effects were not observed. Therefore we recommend the combination of maize cobs and woodchips to enhance NO3− removal while minimizing adverse effects in denitrification beds. PMID:21880343

  6. Changes in density of on-premises alcohol outlets and impact on violent crime, Atlanta, Georgia, 1997-2007.

    PubMed

    Zhang, Xingyou; Hatcher, Bonnie; Clarkson, Lydia; Holt, James; Bagchi, Suparna; Kanny, Dafna; Brewer, Robert D

    2015-05-28

    Regulating alcohol outlet density is an evidence-based strategy for reducing excessive drinking. However, the effect of this strategy on violent crime has not been well characterized. A reduction in alcohol outlet density in the Buckhead neighborhood of Atlanta from 2003 through 2007 provided an opportunity to evaluate this effect. We conducted a community-based longitudinal study to evaluate the impact of changes in alcohol outlet density on violent crime in Buckhead compared with 2 other cluster areas in Atlanta (Midtown and Downtown) with high densities of alcohol outlets, from 1997 through 2002 (preintervention) to 2003 through 2007 (postintervention). The relationship between exposures to on-premises retail alcohol outlets and violent crime were assessed by using annual spatially defined indices at the census block level. Multilevel regression models were used to evaluate the relationship between changes in exposure to on-premises alcohol outlets and violent crime while controlling for potential census block-level confounders. A 3% relative reduction in alcohol outlet density in Buckhead from 1997-2002 to 2003-2007 was associated with a 2-fold greater reduction in exposure to violent crime than occurred in Midtown or Downtown, where exposure to on-premises retail alcohol outlets increased. The magnitude of the association between exposure to alcohol outlets and violent crime was 2 to 5 times greater in Buckhead than in either Midtown or Downtown during the postintervention period. A modest reduction in alcohol outlet density can substantially reduce exposure to violent crime in neighborhoods with high density of alcohol outlets. Routine monitoring of community exposure to alcohol outlets could also inform the regulation of alcohol outlet density, consistent with Guide to Community Preventive Services recommendations.

  7. Neighborhood disparities in access to healthy foods and their effects on environmental justice

    USDA-ARS?s Scientific Manuscript database

    Environmental justice is concerned with an equitable distribution of environmental burdens. These burdens comprise immediate health hazards as well as subtle inequities, such as limited access to healthy foods. We reviewed the literature on neighborhood disparities in access to fast-food outlets and...

  8. 40 CFR 63.9320 - What procedures must I use?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the carbon monoxide (CO) or total hydrocarbon (THC) concentration limitation consists of the first 4-hour rolling average CO or THC concentration recorded after completion of the CEMS performance evaluation. You must correct the CO or THC concentration at the outlet of the engine test cell/stand or the...

  9. 40 CFR 63.9320 - What procedures must I use?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the carbon monoxide (CO) or total hydrocarbon (THC) concentration limitation consists of the first 4-hour rolling average CO or THC concentration recorded after completion of the CEMS performance evaluation. You must correct the CO or THC concentration at the outlet of the engine test cell/stand or the...

  10. 40 CFR 63.9320 - What procedures must I use?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the carbon monoxide (CO) or total hydrocarbon (THC) concentration limitation consists of the first 4-hour rolling average CO or THC concentration recorded after completion of the CEMS performance evaluation. You must correct the CO or THC concentration at the outlet of the engine test cell/stand or the...

  11. 40 CFR 63.9320 - What procedures must I use?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the carbon monoxide (CO) or total hydrocarbon (THC) concentration limitation consists of the first 4-hour rolling average CO or THC concentration recorded after completion of the CEMS performance evaluation. You must correct the CO or THC concentration at the outlet of the engine test cell/stand or the...

  12. 40 CFR 63.9320 - What procedures must I use?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the carbon monoxide (CO) or total hydrocarbon (THC) concentration limitation consists of the first 4-hour rolling average CO or THC concentration recorded after completion of the CEMS performance evaluation. You must correct the CO or THC concentration at the outlet of the engine test cell/stand or the...

  13. 40 CFR Table 2 to Subpart Jjjj of... - Requirements for Performance Tests

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... requirements 1. Stationary SI internal combustion engine demonstrating compliance according to § 60.4244 a. limit the concentration of NOX in the stationary SI internal combustion engine exhaust i. Select the... the outlet of the control device. ii. Determine the O2 concentration of the stationary internal...

  14. 30 CFR 7.96 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... diesel engine with an intake system, exhaust system, and a safety shutdown system installed. Dry exhaust.... A system connected to the outlet of the diesel engine which includes, but is not limited to, the... constructed that flame or sparks from the diesel engine cannot propagate an explosion of a flammable mixture...

  15. 30 CFR 7.96 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... diesel engine with an intake system, exhaust system, and a safety shutdown system installed. Dry exhaust.... A system connected to the outlet of the diesel engine which includes, but is not limited to, the... constructed that flame or sparks from the diesel engine cannot propagate an explosion of a flammable mixture...

  16. A description of interventions promoting healthier ready-to-eat meals (to eat in, to take away, or to be delivered) sold by specific food outlets in England: a systematic mapping and evidence synthesis.

    PubMed

    Hillier-Brown, Frances C; Summerbell, Carolyn D; Moore, Helen J; Wrieden, Wendy L; Adams, Jean; Abraham, Charles; Adamson, Ashley; Araújo-Soares, Vera; White, Martin; Lake, Amelia A

    2017-01-19

    Ready-to-eat meals (to eat in, to take away or to be delivered) sold by food outlets are often more energy dense and nutrient poor compared with meals prepared at home, making them a reasonable target for public health intervention. The aim of the research presented in this paper was to systematically identify and describe interventions to promote healthier ready-to-eat meals (to eat in, to take away, or to be delivered) sold by specific food outlets in England. A systematic search and sift of the literature, followed by evidence mapping of relevant interventions, was conducted. Food outlets were included if they were located in England, were openly accessible to the public and, as their main business, sold ready-to-eat meals. Academic databases and grey literature were searched. Also, local authorities in England, topic experts, and key health professionals and workers were contacted. Two tiers of evidence synthesis took place: type, content and delivery of each intervention were summarised (Tier 1) and for those interventions that had been evaluated, a narrative synthesis was conducted (Tier 2). A total of 75 interventions were identified, the most popular being awards. Businesses were more likely to engage with cost neutral interventions which offered imperceptible changes to price, palatability and portion size. Few interventions involved working upstream with suppliers of food, the generation of customer demand, the exploration of competition effects, and/or reducing portion sizes. Evaluations of interventions were generally limited in scope and of low methodological quality, and many were simple assessments of acceptability. Many interventions promoting healthier ready-to-eat meals (to eat in, to take away, or to be delivered) sold by specific food outlets in England are taking place; award-type interventions are the most common. Proprietors of food outlets in England that, as their main business, sell ready-to-eat meals, can be engaged in implementing interventions to promote healthier ready-to-eat-food. These proprietors are generally positive about such interventions, particularly when they are cost neutral and use a health by stealth approach.

  17. The challenges of interventions to promote healthier food in independent takeaways in England: qualitative study of intervention deliverers' views.

    PubMed

    Goffe, Louis; Penn, Linda; Adams, Jean; Araujo-Soares, Vera; Summerbell, Carolyn D; Abraham, Charles; White, Martin; Adamson, Ashley; Lake, Amelia A

    2018-01-27

    Much of the food available from takeaways, pubs and restaurants particularly that sold by independent outlets, is unhealthy and its consumption is increasing. These food outlets are therefore important potential targets for interventions to improve diet and thus prevent diet related chronic diseases. Local authorities in England have been charged with delivering interventions to increase the provision of healthy food choices in independent outlets, but prior research shows that few such interventions have been rigorously developed or evaluated. We aimed to learn from the experiences of professionals delivering interventions in independent food outlets in England to identify the operational challenges and their suggestions for best practice. We used one-to-one semi-structured qualitative interviews to explore the views and experiences of professionals who were either employees of, or contracted by, a local authority to deliver interventions to increase the provision of healthier food choices in independent food outlets. Purposive sampling was used to recruit a sample which included men and women, from a range of professional roles, across different areas of England. Interviews were informed by a topic guide, and proceeded until no new themes emerged. Interviews were recorded, transcribed verbatim and analysed using the Framework method. We conducted 11 individual interviews. Participants focussed on independent takeaways and their unhealthy food offerings, and highlighted the advantages and disadvantages of intervention delivery methods, their evaluation and impact. The main barriers to implementation of interventions in independent takeaways were identified as limited funding and the difficulties of engaging the food outlet owner/manager. Engagement was thought to be facilitated by delivering intensive, interactive and tailored interventions, clear and specific information, and incentives, whilst accounting for practical, primarily financial, constraints of food businesses. Alternative intervention approaches, targeting suppliers or customers, were suggested. Participants emphasised independent takeaways as particularly challenging, but worthwhile intervention targets. Participants perceived that interventions need to take account of the potentially challenging operating environment, particularly the primacy of the profit motive. Upstream interventions, engaging suppliers, as well as those that drive consumer demand, may be worth exploring. Rigorous, evidence-informed development and evaluation of such interventions is needed.

  18. A population-based study of premature mortality in relation to neighbourhood density of alcohol sales and cheque cashing outlets in Toronto, Canada.

    PubMed

    Matheson, Flora I; Creatore, Maria Isabella; Gozdyra, Piotr; Park, Alison L; Ray, Joel G

    2014-12-17

    Alcohol overuse and poverty, each associated with premature death, often exist within disadvantaged neighbourhoods. Cheque cashing places (CCPs) may be opportunistically placed in disadvantaged neighbourhoods, where customers abound. We explored whether neighbourhood density of CCPs and alcohol outlets are each related to premature mortality among adults. Retrospective population-based study. 140 neighbourhoods in Toronto, Ontario, 2005-2009. Adults aged 20-59 years. Our primary outcome was premature all-cause mortality among adults aged 20-59 years. Across neighbourhoods we explored neighbourhood density, in km(2), of CCPs and alcohol outlets, and the relation of each to premature mortality. Poisson regression provided adjusted relative risks (aRRs) and 95% CIs, adjusting for material deprivation quintile (Q), crime Q and number of banks. Intentional self-harm, accidental poisoning and liver disease were among the top five causes of premature death among males aged 20-59 years. The overall premature mortality rate was 96.3/10,000 males and 55.9/10,000 females. Comparing the highest versus lowest CCP density Q, the aRR for death was 1.25 (95% CI 1.15 to 1.36) among males and 1.11 (95% CI 0.99 to 1.24) among females. The corresponding aRR comparing the highest Q versus lowest Q alcohol outlet density in relation to premature mortality was 1.36 (95% CI 1.25 to 1.48) for males and 1.11 (95% CI 1.00 to 1.24) for females. The pattern of the relation between either CCPs or alcohol outlet density and premature mortality was typically J shaped. There is a J-shaped relation between CCP or alcohol outlet density and premature mortality, even on controlling for conventional measures of poverty. Formal banking and alcohol reduction strategies might be added to health promotion policies aimed at reducing premature mortality in highly affected neighbourhoods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Flow rate and temperature characteristics in steady state condition on FASSIP-01 loop during commissioning

    NASA Astrophysics Data System (ADS)

    Juarsa, M.; Giarno; Rohman, A. N.; Heru K., G. B.; Witoko, J. P.; Sony Tjahyani, D. T.

    2018-02-01

    The need for large-scale experimental facilities to investigate the phenomenon of natural circulation flow rate becomes a necessity in the development of nuclear reactor safety management. The FASSIP-01 loop has been built to determine the natural circulation flow rate performance in the large-scale media and aimed to reduce errors in the results for its application in the design of new generation reactors. The commissioning needs to be done to define the capability of the FASSIP-01 loop and to prescribe the experiment limitations. On this commissioning, two scenarios experimental method has been used. The first scenario is a static condition test which was conducted to verify measurement system response during 24 hours without electrical load in heater and cooler, there is water and no water inside the rectangular loop. Second scenario is a dynamics condition that aims to understand the flow rate, a dynamic test was conducted using heater power of 5627 watts and coolant flow rate in the HSS loop of 9.35 LPM. The result of this test shows that the temperature characterization on static test provide a recommendation, that the experiments should be done at night because has a better environmental temperature stability compared to afternoon, with stable temperature around 1°C - 3°C. While on the dynamic test, the water temperature difference between the inlet-outlets in the heater area is quite large, about 7 times the temperature difference in the cooler area. The magnitude of the natural circulation flow rate calculated is much larger at about 300 times compared to the measured flow rate with different flow rate profiles.

  20. To sell or not to sell: cigarette sales in alcohol-licenced premises.

    PubMed

    Burton, Suzan; Ludbrooke, Mark; Williams, Kelly; Walsberger, Scott C; Egger, Sam

    2017-11-27

    To obtain insight into tobacco retailing by alcohol-licenced premises, in order to understand the financial importance of tobacco sales for such retailers. Data were collected by a telephone survey of 1042 clubs, hotels and packaged liquor outlets in New South Wales, Australia. The response rate was 86.1%. Qualitative and quantitative data were obtained. Logistic and linear regression were used to determine factors associated with the probability of selling and stopping selling and the importance of cigarette sales. More than a third (36.4%) of premises contacted did not sell cigarettes. 147 (an estimated 18.1% of those who had ever sold) had stopped selling. There were significant differences in the probability of selling, in the reported importance of cigarette sales and in the probability of stopping selling, between different outlet types and other outlet characteristics (number of gaming machines, proximity of nearest alternative tobacco retailer and remoteness). Outlets where alcohol can be consumed were more likely to rate cigarette sales as 'not important' than 'important'. Despite claims by tobacco companies that tobacco sales are important for many Australian retailers, tobacco sales appear to be of limited importance for alcohol-licenced premises. This means that opposition to stopping tobacco sales where alcohol is consumed and/or sold may be less than expected. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. An ecological analysis of food outlet density and prevalence of type II diabetes in South Carolina counties.

    PubMed

    AlHasan, Dana M; Eberth, Jan Marie

    2016-01-05

    Studies suggest that the built environment with high numbers of fast food restaurants and convenience stores and low numbers of super stores and grocery stores are related to obesity, type II diabetes mellitus, and other chronic diseases. Since few studies assess these relationships at the county level, we aim to examine fast food restaurant density, convenience store density, super store density, and grocery store density and prevalence of type II diabetes among counties in South Carolina. Pearson's correlation between four types of food outlet densities- fast food restaurants, convenience stores, super stores, and grocery stores- and prevalence of type II diabetes were computed. The relationship between each of these food outlet densities were mapped with prevalence of type II diabetes, and OLS regression analysis was completed adjusting for county-level rates of obesity, physical inactivity, density of recreation facilities, unemployment, households with no car and limited access to stores, education, and race. We showed a significant, negative relationship between fast food restaurant density and prevalence of type II diabetes, and a significant, positive relationship between convenience store density and prevalence of type II diabetes. In adjusted analysis, the food outlet densities (of any type) was not associated with prevalence of type II diabetes. This ecological analysis showed no associations between fast food restaurants, convenience stores, super stores, or grocery stores densities and the prevalence of type II diabetes. Consideration of environmental, social, and cultural determinants, as well as individual behaviors is needed in future research.

  2. Relating off-premises alcohol outlet density to intentional and unintentional injuries.

    PubMed

    Morrison, Christopher; Smith, Karen; Gruenewald, Paul J; Ponicki, William R; Lee, Juliet P; Cameron, Peter

    2016-01-01

    This study investigated the hypotheses that (i) intentional and unintentional injuries occur more frequently in areas with greater density of off-premises alcohol outlets; and (ii) larger and chain outlets selling cheaper alcohol contribute more substantially to injury risk than smaller and independent outlets. Ecological cross-sectional. From the 256 Statistical Area level 2 (SA2) census units in Melbourne, Australia, we selected a random sample of 62 units. There were 2119 Statistical Area level 1 (SA1) units nested within the selected SA2 units. The selected units contained 295 off-premises outlets. Two independent observers conducted premises assessments in all off-premises outlets, assessing the volume of alcohol available for sale (paces of shelf space), price (least wine price) and other operating characteristics (chain versus independent, drive-through). Outlet counts, assessed outlet characteristics and other area characteristics (population density, median age, median income, retail zoning) were aggregated within SA1 units. Dependent variables were counts of ambulance attended intentional injuries (assaults, stabbings, shootings) and unintentional injuries (falls, crush injuries and object strikes). In univariable analyses, chain outlets were larger (r = 0.383; P < 0.001) and sold cheaper alcohol (r = -0.484; P < 0.001) compared with independent outlets. In Bayesian spatial Poisson models, off-premises outlet density was positively related to both intentional [incidence rate ratio (IRR) = 1.38; 95% credible interval (CI) = 1.19, 1.60] and unintentional injuries (IRR = 1.18; 95% CI = 1.06, 1.30). After disaggregation by outlet characteristics, chain outlet density was also related to both intentional (IRR = 1.35; 95% CI = 1.11, 1.64) and unintentional injuries (IRR = 1.20; 95% CI = 1.08, 1.38). Greater off-premises outlet density is related to greater incidence of traumatic injury, and chain outlets appear to contribute most substantially to traumatic injury risk. © 2015 Society for the Study of Addiction.

  3. Relating Off-Premises Alcohol Outlet Density to Intentional and Unintentional Injuries

    PubMed Central

    Morrison, Christopher; Smith, Karen; Gruenewald, Paul J.; Ponicki, William R.; Lee, Juliet P.; Cameron, Peter

    2015-01-01

    Aims This study investigated the hypotheses that (i) intentional and unintentional injuries occur more frequently in areas with greater density of off-premises alcohol outlets; and (ii) larger and chain outlets selling cheaper alcohol contribute more substantially to injury risk than smaller and independent outlets. Design Ecological cross-sectional. Setting From the 256 Statistical Area level 2 (SA2) Census units in Melbourne, Australia, we selected a random sample of 62 units. There were 2,119 Statistical Area level 1 (SA1) units nested within the selected SA2 units. Participants The selected units contained 295 off-premises outlets. Measurements Two independent observers conducted premises assessments in all off-premises outlets, assessing the volume of alcohol available for sale (paces of shelf space), price (least wine price), and other operating characteristics (chain vs. independent, drive-through). Outlet counts, assessed outlet characteristics, and other area characteristics (population density, median age, median income, retail zoning) were aggregated within SA1 units. Dependent variables were counts of ambulance attended intentional injuries (assaults, stabbings, shootings) and unintentional injuries (falls, crush injuries, and object strikes). Findings In univariable analyses, chain outlets were larger (r = 0.383; p < 0.001) and sold cheaper alcohol (r = −0.484; p < 0.001) compared with independent outlets. In Bayesian spatial Poisson models, off-premises outlet density was positively related to both intentional (Incidence Rate Ratio = 1.38; 95% Credible Interval: 1.19, 1.60) and unintentional injuries (IRR = 1.18; 95% CI: 1.06, 1.30). After disaggregation by outlet characteristics, chain outlet density was also related to both intentional (IRR = 1.35; 95% CI: 1.11, 1.64) and unintentional injuries (IRR = 1.20; 95% CI: 1.08, 1.38). Conclusions Greater off-premises outlet density is related to greater incidence of traumatic injury, and chain outlets appear to contribute most substantially to traumatic injury risk. PMID:26283189

  4. Flat plate solar air heater with latent heat storage

    NASA Astrophysics Data System (ADS)

    Touati, B.; Kerroumi, N.; Virgone, J.

    2017-02-01

    Our work contains two parts, first is an experimental study of the solar air heater with a simple flow and forced convection, we can use thatlaste oneit in many engineering's sectors as solardrying, space heating in particular. The second part is a numerical study with ansys fluent 15 of the storage of part of this solar thermal energy produced,using latent heat by using phase change materials (PCM). In the experimental parts, we realize and tested our solar air heater in URER.MS ADRAR, locate in southwest Algeria. Where we measured the solarradiation, ambient temperature, air flow, thetemperature of the absorber, glasses and the outlet temperature of the solar air heater from the Sunrise to the sunset. In the second part, we added a PCM at outlet part of the solar air heater. This PCM store a part of the energy produced in the day to be used in peak period at evening by using the latent heat where the PCMs present a grateful storagesystem.A numerical study of the fusion or also named the charging of the PCM using ANSYS Fluent 15, this code use the method of enthalpies to solve the fusion and solidification formulations. Furthermore, to improve the conjugate heat transfer between the heat transfer fluid (Air heated in solar plate air heater) and the PCM, we simulate the effect of adding fins to our geometry. Also, four user define are write in C code to describe the thermophysicalpropriety of the PCM, and the inlet temperature of our geometry which is the temperature at the outflow of the solar heater.

  5. Devise of an exhaust gas heat exchanger for a thermal oil heater in a palm oil refinery plant

    NASA Astrophysics Data System (ADS)

    Chucherd, Panom; Kittisupakorn, Paisan

    2017-08-01

    This paper presents the devise of an exhaust gas heat exchanger for waste heat recovery of the exhausted flue gas of palm oil refinery plant. This waste heat can be recovered by installing an economizer to heat the feed water which can save the fuel consumption of the coal fired steam boiler and the outlet temperature of flue gas will be controlled in order to avoid the acid dew point temperature and protect the filter bag. The decrease of energy used leads to the reduction of CO2 emission. Two designed economizer studied in this paper are gas in tube and water in tube. The gas in tube exchanger refers to the shell and tube heat exchanger which the flue gas flows in tube; this designed exchanger is used in the existing unit. The new designed water in tube refers to the shell and tube heat exchanger which the water flows in the tube; this designed exchanger is proposed for new implementation. New economizer has the overall coefficient of heat transfer of 19.03 W/m2.K and the surface heat transfer area of 122 m2 in the optimized case. Experimental results show that it is feasible to install economizer in the exhaust flue gas system between the air preheater and the bag filter, which has slightly disadvantage effect in the system. The system can raise the feed water temperature from 40 to 104°C and flow rate 3.31 m3/h, the outlet temperature of flue gas is maintained about 130 °C.

  6. Revealing the link between licensed outlets and violence: counting venues versus measuring alcohol availability.

    PubMed

    Liang, Wenbin; Chikritzhs, Tanya

    2011-09-01

    Associations between alcohol-related harms and numbers of outlets at the neighbourhood level have been demonstrated; however, the degree to which alcohol consumption or sales plays a part in levels of violence is not clear. This has contributed to uncertainty regarding the actual mechanisms by which outlet density may influence levels of violence. This ecological cross-sectional study investigated the effect of outlet numbers and alcohol sales on the risk of assault in Western Australia. For 2000/2001, information on type, number and wholesale alcohol purchases of all licensed outlets in operation, police-reported assault offences, socioeconomic/demographic data were obtained from official sources. Multivariate negative binomial regression was applied to at local government area level in order to assess associations between outlet density, alcohol sales and violence occurring in both licensed and domestic settings. Average alcohol sales volume per off-site outlet was significantly associated with all measures of assault. Numbers of on-site outlets significantly predicted violence with the exception of assaults occurring at residential premises. Alcohol sales from off-site outlets predicted violence occurring at on-site outlets. The link between on-site outlets and violence may be primarily underpinned by negative amenity effects while off-site outlet effects occur via increased availability. Alcohol sales volumes from off-site outlets influence levels of violence, which occur at both licensed and residential settings. The substantial and wide-ranging effects of liquor stores on alcohol-related harms may have been underestimated in the literature and by policy makers. © 2011 Australasian Professional Society on Alcohol and other Drugs.

  7. The inequitable distribution of tobacco outlet density: the role of income in two Black Mid-Atlantic geopolitical areas.

    PubMed

    Fakunle, D O; Milam, A J; Furr-Holden, C D; Butler, J; Thorpe, R J; LaVeist, T A

    2016-07-01

    Studies have shown that communities with higher concentrations of low-income racial and ethnic minorities correlate with a greater presence of tobacco outlets. Community-level income has consistently been among the strongest predictors of tobacco outlet density. This study analyzes two Maryland geopolitical areas with similar racial concentrations yet differing income levels in an attempt to disentangle the race-income relationship with tobacco outlet density. In this cross-sectional examination of tobacco outlet and census tract-level sociodemographic data, Baltimore City, Maryland, and Prince George's County, Maryland, were geocoded to determine tobacco outlet density. Tobacco outlet density was defined as the mean number of tobacco outlets per 1000 persons per census tract. Comparisons of tobacco outlet density and sociodemographic variables were analysed via two-sample t-tests, and the direct effect of sociodemographic variables on tobacco outlet density for each area was analysed via spatial lag regressions. Prince George's County, the area with the higher income level ($77,190 vs $43,571), has a significantly lower tobacco outlet density than Baltimore City (P < 0.001). Prince George's County has a 67.5% Black population and an average of 3.94 tobacco outlets per 1000 persons per tract. By contrast, Baltimore City has a 65.3% Black population and an average of 7.95 tobacco outlets per 1000 persons per tract. Spatial lag regression model results indicate an inverse relationship between income and tobacco outlet density in Baltimore City and Prince George's County (β = -0.03, P < 0.01 &β = -0.01, P = 0.02, respectively), and a significant interaction term indicating a greater magnitude in the relationship between income and tobacco outlet density in Baltimore City (β = -0.05, P < 0.01). Results suggest that higher socio-economic status, even in primarily underrepresented racial and ethnic geopolitical areas, is linked to lower tobacco outlet density. Copyright © 2016 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  8. System for utilizing oil shale fines

    DOEpatents

    Harak, Arnold E.

    1982-01-01

    A system is provided for utilizing fines of carbonaceous materials such as particles or pieces of oil shale of about one-half inch or less diameter which are rejected for use in some conventional or prior surface retorting process, which obtains maximum utilization of the energy content of the fines and which produces a waste which is relatively inert and of a size to facilitate disposal. The system includes a cyclone retort (20) which pyrolyzes the fines in the presence of heated gaseous combustion products, the cyclone retort having a first outlet (30) through which vapors can exit that can be cooled to provide oil, and having a second outlet (32) through which spent shale fines are removed. A burner (36) connected to the spent shale outlet of the cyclone retort, burns the spent shale with air, to provide hot combustion products (24) that are carried back to the cyclone retort to supply gaseous combustion products utilized therein. The burner heats the spent shale to a temperature which forms a molten slag, and the molten slag is removed from the burner into a quencher (48) that suddenly cools the molten slag to form granules that are relatively inert and of a size that is convenient to handle for disposal in the ground or in industrial processes.

  9. Bidirectional piston valve

    DOEpatents

    Fischer, Harry C.

    1977-01-01

    This invention is a reversing valve having an inlet, an outlet, and an inlet-outlet port. The valve is designed to respond to the introduction of relatively high-pressure fluid at its inlet or, alternatively, of lower-pressure fluid at its inlet-outlet port. The valve includes an axially slidable assembly which is spring-biased to a position where it isolates the inlet and connects the inlet-outlet port to the outlet. The admission of high-pressure fluid to the inlet displaces the slidable assembly to a position where the outlet is isolated and the inlet is connected to the inlet-outlet port. The valve is designed to minimize pressure drops and leakage. It is of a reliable and comparatively simple design.

  10. Fuel injection and mixing systems and methods of using the same

    DOEpatents

    Mao, Chien-Pei; Short, John

    2010-08-03

    A fuel injection and mixing system is provided. The system includes an injector body having a fuel inlet and a fuel outlet, and defines a fuel flow path between the inlet and outlet. The fuel flow path may include a generally helical flow passage having an inlet end portion disposed proximate the fuel inlet of the injector body. The flow path also may include an expansion chamber downstream from and in fluid communication with the helical flow passage, as well as a fuel delivery device in fluid communication with the expansion chamber for delivering fuel. Heating means is also provided in thermal communication with the injector body. The heating means may be adapted and configured for maintaining the injector body at a predetermined temperature to heat fuel traversing the flow path. A method of preheating and delivering fuel is also provided.

  11. Method of making hermetic seals for hermetic terminal assemblies

    DOEpatents

    Hsu, John S.; Marlino, Laura D.; Ayers, Curtis W.

    2010-04-13

    This invention teaches methods of making a hermetic terminal assembly comprising the steps of: inserting temporary stops, shims and jigs on the bottom face of a terminal assembly thereby blocking assembly core open passageways; mounting the terminal assembly inside a vacuum chamber using a temporary assembly perimeter seal and flange or threaded assembly interfaces; mixing a seal admixture and hardener in a mixer conveyor to form a polymer seal material; conveying the polymer seal material into a polymer reservoir; feeding the polymer seal material from the reservoir through a polymer outlet valve and at least one polymer outlet tube into the terminal assembly core thereby filling interstitial spaces in the core adjacent to service conduits, temporary stop, and the terminal assembly casing; drying the polymer seal material at room temperature thereby hermetically sealing the core of the terminal assembly; removing the terminal assembly from the vacuum chamber, and; removing the temporary stops, shims.

  12. Coolant mixing in LMFBR rod bundles and outlet plenum mixing transients. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todreas, N.E.; Cheng, S.K.; Basehore, K.

    1984-08-01

    This project principally undertook the investigation of the thermal hydraulic performance of wire wrapped fuel bundles of LMFBR configuration. Results obtained included phenomenological models for friction factors, flow split and mixing characteristics; correlations for predicting these characteristics suitable for insertion in design codes; numerical codes for analyzing bundle behavior both of the lumped subchannel and distributed parameter categories and experimental techniques for pressure velocity, flow split, salt conductivity and temperature measurement in water cooled mockups of bundles and subchannels. Flow regimes investigated included laminar, transition and turbulent flow under forced convection and mixed convection conditions. Forced convections conditions were emphasized.more » Continuing efforts are underway at MIT to complete the investigation of the mixed convection regime initiated here. A number of investigations on outlet plenum behavior were also made. The reports of these investigations are identified.« less

  13. Mathematical modelling of cyclic pressure swing adsorption processes

    NASA Astrophysics Data System (ADS)

    Skvortsov, S. A.; Akulinin, E. I.; Golubyatnikov, O. O.; Dvoretsky, D. S.; Dvoretsky, S. I.

    2018-05-01

    The paper discusses the results of a numerical analysis of the properties and regimes of the adsorption air separation and oxygen concentration process with a purity of ∼ 40-60%, carried out in a 2-adsorption vacuum-pressure plant with a granular zeolite adsorbent 13X with a productivity of 1.6 · 10-5 m3/s. Computational experiments were carried out using the developed mathematical model and the influence of temperature, pressure, reflux ratio, the duration of the adsorption and desorption stages, the harmonic fluctuations of the inlet pressure during the adsorption stage and the outlet pressure during the desorption stage on the kinetics, and the efficiency of the air separation process by the PSA method were investigated. It is established that the specially organized harmonic fluctuations of the inlet pressure at the stage of adsorption and outlet pressure during the desorption stage lead to an increase in the purity of product oxygen by 4% (vol.).

  14. The PLVCR 500 and HCPC, tests and results

    NASA Astrophysics Data System (ADS)

    Leuchsner, Volker

    1991-09-01

    Developments of volumetric receivers during the last decade which have pointed out the advantages and the wide range of applications in comparison with tube receivers are reported. During three test periods in 1990 the 500 kW version of the Pressure Loaded Volumetric Ceramic Receiver (PLVCR 500) and the Hexagonal Compound Parabolic Concentrator (HCPC) were mounted on the Small Solar Power System (SSPS) tower. Concerning the size of the experiment, it represents the most extensive research and development work on pressure loaded volumetric receivers until now. The receiver and the secondary concentrator were tested together and separately. A gauge pressure of 4.2 bars at air outlet temperatures of 960 C was reached. The secondary concentrator was tested under various flux conditions, the inlet and outlet flux distributions were measured. With this test the feasibility of a modular design of receiver and secondary concentrator could be shown.

  15. Annular core liquid-salt cooled reactor with multiple fuel and blanket zones

    DOEpatents

    Peterson, Per F.

    2013-05-14

    A liquid fluoride salt cooled, high temperature reactor having a reactor vessel with a pebble-bed reactor core. The reactor core comprises a pebble injection inlet located at a bottom end of the reactor core and a pebble defueling outlet located at a top end of the reactor core, an inner reflector, outer reflector, and an annular pebble-bed region disposed in between the inner reflector and outer reflector. The annular pebble-bed region comprises an annular channel configured for receiving pebble fuel at the pebble injection inlet, the pebble fuel comprising a combination of seed and blanket pebbles having a density lower than the coolant such that the pebbles have positive buoyancy and migrate upward in said annular pebble-bed region toward the defueling outlet. The annular pebble-bed region comprises alternating radial layers of seed pebbles and blanket pebbles.

  16. Development of CE-QUAL-W2 models for the Middle Fork Willamette and South Santiam Rivers, Oregon

    USGS Publications Warehouse

    Buccola, Norman L.; Stonewall, Adam J.; Sullivan, Annett B.; Kim, Yoonhee; Rounds, Stewart A.

    2013-01-01

    Hydrodynamic (CE-QUAL-W2) models of Hills Creek Lake (HCL), Lookout Point Lake (LOP), and Dexter Lake (DEX) on the Middle Fork Willamette River (MFWR), and models of Green Peter Lake and Foster Lake on the South Santiam River systems in western Oregon were updated and recalibrated for a wide range of flow and meteorological conditions. These CE-QUAL-W2 models originally were developed by West Consultants, Inc., for the U.S. Army Corps of Engineers. This study by the U.S. Geological Survey included a reassessment of the models’ calibration in more recent years—2002, 2006, 2008, and 2011—categorized respectively as low, normal, high, and extremely high flow calendar years. These years incorporated current dam-operation practices and more available data than the time period used in the original calibration. Modeled water temperatures downstream of both HCL and LOP-DEX on the MFWR were within an average of 0.68 degree Celsius (°C) of measured values; modeled temperatures downstream of Foster Dam on the South Santiam River were within an average of 0.65°C of measured values. A new CE-QUAL-W2 model was developed and calibrated for the riverine MFWR reach between Hills Creek Dam and the head of LOP, allowing an evaluation of the flow and temperature conditions in the entire MFWR system from HCL to Dexter Dam. The complex bathymetry and long residence time of HCL, combined with the relatively deep location of the power and regulating outlet structures at Hills Creek Dam, led to a HCL model that was highly sensitive to several outlet and geometric parameters related to dam structures (STR TOP, STR BOT, STR WIDTH). Release temperatures from HCL were important and often persisted downstream as they were incorporated in the MFWR model and the LOP-DEX model (downstream of MFWR). The models tended to underpredict the measured temperature of water releases from Dexter Dam during the late-September-through-December drawdown period in 2002, and again (to a lesser extent) in 2011, but simulations were much more accurate in 2006 and 2008. This episodic model bias may have been a result of hot, dry conditions; lower lake elevations; and earlier drawdown at both HCL and LOP in 2002. These dry conditions in 2002 may have contradicted assumptions inherent in the estimation of certain model inputs, such as unmeasured inflows and water temperatures, which may respond differently during dry years than during normal and wet years. This report documents the development and calibration of new and revised flow and water-temperature models for riverine and reservoir reaches in the Middle Fork Willamette River and South Santiam River systems. Methods and model parameter values were established for the accurate simulation of flows and temperatures in these systems under current conditions. By extension, these models should be able to accurately simulate flows and temperatures under potential future conditions in which dam operations and dam outlet structures may be changed as part of a strategy to improve habitat, fish passage, and temperature conditions for endangered fish.

  17. Relationship between community-level alcohol outlet accessibility and individual-level herpes simplex virus type 2 infection among young women in South Africa.

    PubMed

    Rosenberg, Molly; Pettifor, Audrey; Lippman, Sheri A; Thirumurthy, Harsha; Emch, Michael; Miller, William C; Selin, Amanda; Gómez-Olivé, Francesc Xavier; Hughes, James P; Laeyendecker, Oliver; Tollman, Stephen; Kahn, Kathleen

    2015-05-01

    Exposure to alcohol outlets may influence sexual health outcomes at the individual and community levels. Visiting alcohol outlets facilitates alcohol consumption and exposes patrons to a risky environment and network of potential partners, whereas the presence of alcohol outlets in the community may shift social acceptance of riskier behavior. We hypothesize that living in communities with more alcohol outlets is associated with increased sexual risk. We performed a cross-sectional analysis in a sample of 2174 South African schoolgirls (ages 13-21 years) living across 24 villages in the rural Agincourt subdistrict, underpinned by long-term health and sociodemographic surveillance. To examine the association between number of alcohol outlets in village of residence and individual-level prevalent herpes simplex virus type 2 (HSV-2) infection, we used generalized estimating equations with logit links, adjusting for individual- and village-level covariates. The median number of alcohol outlets per village was 3 (range, 0-7). Herpes simplex virus type 2 prevalence increased from villages with no outlets (1.4% [95% confidence interval, 0.2-12.1]), to villages with 1 to 4 outlets (4.5% [3.7-5.5]), and to villages with more than 4 outlets (6.3% [5.6, 7.1]). An increase of 1 alcohol outlet per village was associated with an 11% increase in the odds of HSV-2 infection (adjusted odds ratio [95% confidence interval], 1.11 [0.98-1.25]). Living in villages with more alcohol outlets was associated with increased prevalence of HSV-2 infection in young women. Structural interventions and sexual health screenings targeting villages with extensive alcohol outlet environments could help prevent the spread of sexually transmitted infections.

  18. Local food environments are associated with girls' energy, sugar-sweetened beverage and snack-food intakes.

    PubMed

    Deierlein, Andrea L; Galvez, Maida P; Yen, Irene H; Pinney, Susan M; Biro, Frank M; Kushi, Lawrence H; Teitelbaum, Susan; Wolff, Mary S

    2014-10-01

    To describe availability and frequency of use of local snack-food outlets and determine whether reported use of these outlets was associated with dietary intakes. Data were cross-sectional. Availability and frequency of use of three types of local snack-food outlets were reported. Daily dietary intakes were based on the average of up to four 24 h dietary recalls. Multivariable linear regression models estimated average daily intakes of energy, sugar-sweetened beverages (SSB) and snack foods/sweets associated with use of outlets. Multi-site, observational cohort study in the USA, 2004-2006. Girls aged 6-8 years (n 1010). Weekly frequency of use of local snack-food outlets increased with number of available types of outlets. Girls with access to only one type of outlet reported consuming food/beverage items less frequently than girls with access to two or three types of outlets (P <0·001). Girls' daily energy, SSB and snack foods/sweets intakes increased with greater use of outlets. Girls who reported using outlets>1 to 3 times/week consumed 0·27 (95 % CI 0·13, 0·40) servings of SSB more daily than girls who reported no use. Girls who reported using outlets>3 times/week consumed 449·61 (95 % CI 134·93, 764·29) kJ, 0·43 (95 % CI 0·29, 0·58) servings of SSB and 0·38 (95 % CI 0·12, 0·65) servings of snack foods/sweets more daily than those who reported no use. Girls' frequency of use of local snack-food outlets increases with the number of available types of outlets and is associated with greater daily intakes of energy and servings of SSB and snack foods/sweets.

  19. Fast quench reactor and method

    DOEpatents

    Detering, B.A.; Donaldson, A.D.; Fincke, J.R.; Kong, P.C.

    1998-05-12

    A fast quench reactor includes a reactor chamber having a high temperature heating means such as a plasma torch at its inlet and a restrictive convergent-divergent nozzle at its outlet end. Reactants are injected into the reactor chamber. The resulting heated gaseous stream is then rapidly cooled by passage through the nozzle. This ``freezes`` the desired end product(s) in the heated equilibrium reaction stage. 7 figs.

  20. Energy consumption analysis and simulation of waste heat recovery technology of ceramic rotary kiln

    NASA Astrophysics Data System (ADS)

    Chen, Zhiguang; Zhou, Yu; Qin, Chaokui; Zhang, Xuemei

    2018-03-01

    Ceramsite is widely used in the construction industry, insulation works and oil industry in China, and the manufacture equipment is mainly industrial kiln. In this paper, energy consumption analysis had been carried out through experimental test of a Ceramsite kiln in Henan province. Results showed that the discharge temperature of Ceramsite was about 1393K, and the waste heat accounted for 22.1% of the total energy consumption. A structure of cyclone preheater which recovered waste heat of the high temperature Ceramsite by blast cooling was designed. Then, using Fluent software, performance of the unit was simulated. The minimum temperature that Ceramsite could reach, heat dissipating capacity of Ceramsite, temperature at air outlet, wall temperature of the unit and pressure loss were analyzed. Performance of the designed unit under different inlet velocity was analyzed as well.

  1. Alcohol outlets, social disorganization, and robberies: accounting for neighborhood characteristics and alcohol outlet types.

    PubMed

    Snowden, Aleksandra J; Freiburger, Tina L

    2015-05-01

    We estimated spatially lagged regression and spatial regime models to determine if the variation in total, on-premise, and off-premise alcohol outlet(1) density is related to robbery density, while controlling for direct and moderating effects of social disorganization.(2) Results suggest that the relationship between alcohol outlet density and robbery density is sensitive to the measurement of social disorganization levels. Total alcohol outlet density and off-premise alcohol outlet density were significantly associated with robbery density when social disorganization variables were included separately in the models. However, when social disorganization levels were captured as a four item index, only the association between off-premise alcohol outlets and robbery density remained significant. More work is warranted in identifying the role of off-premise alcohol outlets and their characteristics in robbery incidents. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Organic flash cycles for efficient power production

    DOEpatents

    Ho, Tony; Mao, Samuel S.; Greif, Ralph

    2016-03-15

    This disclosure provides systems, methods, and apparatus related to an Organic Flash Cycle (OFC). In one aspect, a modified OFC system includes a pump, a heat exchanger, a flash evaporator, a high pressure turbine, a throttling valve, a mixer, a low pressure turbine, and a condenser. The heat exchanger is coupled to an outlet of the pump. The flash evaporator is coupled to an outlet of the heat exchanger. The high pressure turbine is coupled to a vapor outlet of the flash evaporator. The throttling valve is coupled to a liquid outlet of the flash evaporator. The mixer is coupled to an outlet of the throttling valve and to an outlet of the high pressure turbine. The low pressure turbine is coupled to an outlet of the mixer. The condenser is coupled to an outlet of the low pressure turbine and to an inlet of the pump.

  3. Heat sink effect on tumor ablation characteristics as observed in monopolar radiofrequency, bipolar radiofrequency, and microwave, using ex vivo calf liver model.

    PubMed

    Pillai, Krishna; Akhter, Javid; Chua, Terence C; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L

    2015-03-01

    Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices.With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored.With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres.Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected.Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5.MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink.

  4. Heat Sink Effect on Tumor Ablation Characteristics as Observed in Monopolar Radiofrequency, Bipolar Radiofrequency, and Microwave, Using Ex Vivo Calf Liver Model

    PubMed Central

    Pillai, Krishna; Akhter, Javid; Chua, Terence C.; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L.

    2015-01-01

    Abstract Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices. With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored. With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres. Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected. Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5. MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink. PMID:25738477

  5. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry.

    PubMed

    Brust, Hanneke; Willemse, Sander; Zeng, Tuoyu; van Asten, Arian; Koeberg, Mattijs; van der Heijden, Antoine; Bolck, Annabel; Schoenmakers, Peter

    2014-12-29

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times; the analysis of impurities in TNT was performed in 4min. This study shows that impurity profiling of TNT can be used to investigate relations between TNT samples encountered in forensic casework. A wide variety of TNT samples were analyzed with the developed method. Dinitrobenzene, dinitrotoluene, trinitrotoluene and amino-dinitrotoluene isomers were detected at very low levels (<1wt.%) by applying the MS in selected-ion monitoring (SIM) mode. Limits of detection ranged from 6ng/mL for 2,6-dinitrotoluene to 43ng/mL for 4-amino-2,6-dinitrotoluene. Major impurities in TNT were 2,4-dinitrotoluene and 2,3,4-trinitrotoluene. Impurity profiles based on seven compounds showed to be useful to TNT samples from different sources. Statistical analysis of these impurity profiles using likelihood ratios demonstrated the potential to investigate whether two questioned TNT samples encountered in forensic casework are from the same source. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Inadvertent venous air embolism during cesarean section: collapsible intravenous fluid bags without self-sealing outlet have risks. Case report.

    PubMed

    Bakan, Mefkur; Topuz, Ufuk; Esen, Asim; Basaranoglu, Gokcen; Ozturk, Erdogan

    2013-01-01

    The anesthesiologist must be aware of the causes, diagnosis and treatment of venous air embolism and adopt the practice patterns to prevent its occurrence. Although venous air embolism is a known complication of cesarean section, we describe an unusual inattention that causes iatrogenic near fatal venous air embolism during a cesarean section under spinal anesthesia. One of the reasons for using self-collapsible intravenous (IV) infusion bags instead of conventional glass or plastic bottles is to take precaution against air embolism. We also demonstrated the risk of air embolism for two kinds of plastic collapsible intravenous fluid bags: polyvinyl chloride (PVC) and polypropylene-based. Fluid bags without self-sealing outlets pose a risk for air embolism if the closed system is broken down, while the flexibility of the bag limits the amount of air entry. PVC-based bags, which have more flexibility, have significantly less risk of air entry when IV administration set is disconnected from the outlet. Using a pressure bag for rapid infusion can be dangerous without checking and emptying all air from the IV bag. 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  7. Inadvertent venous air embolism during cesarean section: Collapsible intravenous fluid bags without self-sealing outlet have risks. Case report.

    PubMed

    Bakan, Mefkur; Topuz, Ufuk; Esen, Asim; Basaranoglu, Gokcen; Ozturk, Erdogan

    2013-01-01

    The anesthesiologist must be aware of the causes, diagnosis and treatment of venous air embolism and adopt the practice patterns to prevent its occurrence. Although venous air embolism is a known complication of cesarean section, we describe an unusual inattention that causes iatrogenic near fatal venous air embolism during a cesarean section under spinal anesthesia. One of the reasons for using self-collapsible intravenous (IV) infusion bags instead of conventional glass or plastic bottles is to take precaution against air embolism. We also demonstrated the risk of air embolism for two kinds of plastic collapsible intravenous fluid bags: polyvinyl chloride (PVC) and polypropylene-based. Fluid bags without self-sealing outlets pose a risk for air embolism if the closed system is broken down, while the flexibility of the bag limits the amount of air entry. PVC-based bags, which have more flexibility, have significantly less risk of air entry when IV administration set is disconnected from the outlet. Using a pressure bag for rapid infusion can be dangerous without checking and emptying all air from the IV bag. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  8. Quantifying the Impacts of Outlet Control Structures on Lake Hydrology and Ecology

    NASA Astrophysics Data System (ADS)

    Budd, B. M.; Kendall, A. D.; Martin, S. L.; Hyndman, D. W.

    2012-12-01

    There have been limited studies of the impacts of lake level control structures on stream ecology and lake property erosion. We examine the influence of historical lake level management strategies on Higgins Lake in Michigan, which is regionally known for recreation, fisheries, and scenery. Lake control structures have potentially increased shoreline erosion and seasonally-reduced flow through the outlets, likely impacting fish habitat. Concerns over these issues spurred local land owners to seek a study on the possible hydrologic and ecological impacts of the removal or modification of the control structure. Bathymetry maps are fundamental to understanding and managing lake ecosystems. From the 1930's through the 1950's, these maps were developed for thousands of Michigan inland lakes using soundings lowered through holes cut in winter lake ice. Increased land use change and alterations of lake outlets have likely modified erosion and sedimentation rates of these lake systems. Our research includes bathymetry surveys of Higgins Lake using an Acoustic Doppler Current Profiler (ADCP) and side-scan sonar. The new higher-resolution bathymetry serves as the basis for simulating impacts of potential changes in lake management, on a verity of inpoint including shoreline position and fish habitat.

  9. Design of modular control system for grain dryers

    NASA Astrophysics Data System (ADS)

    He, Gaoqing; Liu, Yanhua; Zu, Yuan

    In order to effectively control the temperature of grain drying bin, grain ,air outlet as well as the grain moisture, it designed the control system of 5HCY-35 which is based on MCU to adapt to all grains drying conditions, high drying efficiency, long life usage and less manually. The system includes: the control module of the constant temperature and the temperature difference control in drying bin, the constant temperature control of heating furnace, on-line testing of moisture, variety of grain-circulation speed control and human-computer interaction interface. Spatial curve simulation, which takes moisture as control objectives, controls the constant temperature and the temperature difference in drying bin according to preset parameter by the user or a list to reduce the grains explosive to ensure the seed germination percentage. The system can realize the intelligent control of high efficiency and various drying, the good scalability and the high quality.

  10. Water-balance wodel of a wetland on the Fort Berthold Reservation, North Dakota

    USGS Publications Warehouse

    Vining, Kevin C.

    2007-01-01

    A numerical water-balance model was developed to simulate the responses of a wetland on the Fort Berthold Reservation, North Dakota, to historical and possible extreme hydrological inputs and to changes in hydrological inputs that might occur if a proposed refinery is built on the reservation. Results from model simulations indicated that the study wetland would likely contain water during most historical and extreme-precipitation events with the addition of maximum potential discharges of 0.6 acre-foot per day from proposed refinery holding ponds. Extended periods with little precipitation and above-normal temperatures may result in the wetland becoming nearly dry, especially if potential holding-pond discharges are near zero. Daily simulations based on the historical-enhanced climate data set for May and June 2005, which included holding-pond discharges of 0.6 acre-foot per day, indicated that the study-wetland maximum simulated water volume was about 16.2 acre-feet and the maximum simulated water level was about 1.2 feet at the outlet culvert. Daily simulations based on the extreme summer data set, created to represent an extreme event with excessive June precipitation and holding-pond discharges of 0.6 acre-foot per day, indicated that the study-wetland maximum simulated water volume was about 38.6 acre-feet and the maximum simulated water level was about 2.6 feet at the outlet culvert. A simulation performed using the extreme winter climate data set and an outlet culvert blocked with snow and ice resulted in the greatest simulated wetland water volume of about 132 acre-feet and the greatest simulated water level, which would have been about 6.2 feet at the outlet culvert, but water was not likely to overflow an adjacent highway.

  11. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  12. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  13. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 13 2014-07-01 2014-07-01 false How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  14. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 12 2011-07-01 2009-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  15. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 13 2012-07-01 2012-07-01 false How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  16. Alcohol outlets and clusters of violence

    PubMed Central

    2011-01-01

    Background Alcohol related violence continues to be a major public health problem in the United States. In particular, there is substantial evidence of an association between alcohol outlets and assault. However, because the specific geographic relationships between alcohol outlets and the distribution of violence remains obscured, it is important to identify the spatial linkages that may exist, enhancing public health efforts to curb both violence and morbidity. Methods The present study utilizes police-recorded data on simple and aggravated assaults in Cincinnati, Ohio. Addresses of alcohol outlets for Cincinnati, including all bars, alcohol-serving restaurants, and off-premise liquor and convenience stores were obtained from the Ohio Division of Liquor Control and geocoded for analysis. A combination of proximity analysis, spatial cluster detection approaches and a geographic information system were used to identify clusters of alcohol outlets and the distribution of violence around them. Results A brief review of the empirical work relating to alcohol outlet density and violence is provided, noting that the majority of this literature is cross-sectional and ecological in nature, yielding a somewhat haphazard and aggregate view of how outlet type(s) and neighborhood characteristics like social organization and land use are related to assaultive violence. The results of the statistical analysis for Cincinnati suggest that while alcohol outlets are not problematic per se, assaultive violence has a propensity to cluster around agglomerations of alcohol outlets. This spatial relationship varies by distance and is also related to the characteristics of the alcohol outlet agglomeration. Specifically, spatially dense distributions of outlets appear to be more prone to clusters of assaultive violence when compared to agglomerations with a lower density of outlets. Conclusion With a more thorough understanding of the spatial relationships between alcohol outlets and the distribution of assaults, policymakers in urban areas can make more informed regulatory decisions regarding alcohol licenses. Further, this research suggests that public health officials and epidemiologists need to develop a better understanding of what actually occurs in and around alcohol outlets, determining what factors (whether outlet, neighborhood, or spatially related) help fuel their relationship with violence and other alcohol-related harm. PMID:21542932

  17. Method of measuring heat influx of a cryogenic transfer system. [Patent application

    DOEpatents

    Niemann, R.C.; Zelipsky, S.A.; Rezmer, R.R.; Smelser, P.

    1980-10-29

    A method is provided for measuring the heat influx of a cryogenic transfer system. A gaseous phase of the cryogen used during normal operation of the system is passed through the system. The gaseous cryogen at the inlet to the system is tempered to duplicate the normal operating temperature of the system inlet. The temperature and mass flow rate of the gaseous cryogen is measured at the outlet of the system, and the heat capacity of the cryogen is determined. The heat influx of the system is then determined from known thermodynamic relationships.

  18. Neighbourhood fast food outlets and obesity in children and adults: the CLAN Study.

    PubMed

    Crawford, David A; Timperio, Anna F; Salmon, Jo A; Baur, Louise; Giles-Corti, Billie; Roberts, Rebecca J; Jackson, Michelle L; Andrianopoulos, Nick; Ball, Kylie

    2008-01-01

    We examined associations between density of and proximity to fast food outlets and body weight in a sample of children (137 aged 8-9 years and 243 aged 13-15 years) and their parents (322 fathers and 362 mothers). Children's measured and parents' self-reported heights and weights were used to calculate body mass index (BMI). Locations of major fast food outlets were geocoded. Bivariate linear regression analyses examined associations between the presence of any fast food outlet within a 2 km buffer around participants' homes, fast food outlet density within the 2 km buffer, and distance to the nearest outlet and BMI. Each independent variable was also entered into separate bivariate logistic regression analyses to predict the odds of being overweight or obese. Among older children, those with at least one outlet within 2 km had lower BMI z-scores. The further that fathers lived from an outlet, the higher their BMI. Among 13-15-year-old girls and their fathers, the likelihood of overweight/obesity was reduced by 80% and 50%, respectively, if they had at least one fast food outlet within 2 km of their home. Among older girls, the likelihood of being overweight/obese was reduced by 14% with each additional outlet within 2 km. Fathers' odds of being overweight/obese increased by 13% for each additional kilometre to the nearest outlet. While consumption of fast food has been shown to be associated with obesity, this study provides little support for the concept that exposure to fast food outlets in the local neighbourhood increases risk of obesity.

  19. 40 CFR Table 4 to Subpart Lllll of... - Initial Compliance With Emission Limitations

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... auxiliary fuel achieving a THC destruction efficiency of 95.8 percent i. The THC destruction efficiency of..., and total hydrocarbon outlet concentrations over the performance test during which the THC destruction... table. c. Route the emissions to a combustion device that does not use auxiliary fuel achieving a THC...

  20. 40 CFR Table 4 to Subpart Lllll of... - Initial Compliance With Emission Limitations

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... auxiliary fuel achieving a THC destruction efficiency of 95.8 percent i. The THC destruction efficiency of..., and total hydrocarbon outlet concentrations over the performance test during which the THC destruction... table. c. Route the emissions to a combustion device that does not use auxiliary fuel achieving a THC...

  1. 40 CFR Table 4 to Subpart Lllll of... - Initial Compliance With Emission Limitations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... auxiliary fuel achieving a THC destruction efficiency of 95.8 percent i. The THC destruction efficiency of..., and total hydrocarbon outlet concentrations over the performance test during which the THC destruction... table. c. Route the emissions to a combustion device that does not use auxiliary fuel achieving a THC...

  2. 40 CFR Table 4 to Subpart Lllll of... - Initial Compliance With Emission Limitations

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... auxiliary fuel achieving a THC destruction efficiency of 95.8 percent i. The THC destruction efficiency of..., and total hydrocarbon outlet concentrations over the performance test during which the THC destruction... table. c. Route the emissions to a combustion device that does not use auxiliary fuel achieving a THC...

  3. 40 CFR Table 4 to Subpart Lllll of... - Initial Compliance With Emission Limitations

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... auxiliary fuel achieving a THC destruction efficiency of 95.8 percent i. The THC destruction efficiency of..., and total hydrocarbon outlet concentrations over the performance test during which the THC destruction... table. c. Route the emissions to a combustion device that does not use auxiliary fuel achieving a THC...

  4. 40 CFR Table 2 to Subpart Jjjj of... - Requirements for Performance Tests

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... following requirements 1. Stationary SI internal combustion engine demonstrating compliance according to § 60.4244. a. limit the concentration of NOX in the stationary SI internal combustion engine exhaust i... must be located at the outlet of the control device. ii. Determine the O2 concentration of the...

  5. Another View: In Defense of Vigor over Rigor in Classroom Demonstrations

    ERIC Educational Resources Information Center

    Dunn, Dana S.

    2008-01-01

    Scholarship of teaching and learning (SoTL) demands greater empirical rigor on the part of authors and the editorial process than ever before. Although admirable and important, I worry that this increasing rigor will limit opportunities and outlets for a form of pedagogical vigor--the publication of simple, experiential, but empirically…

  6. 40 CFR 63.1430 - Process vent reporting and recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flames are absent. (2) The following information when using a combustion, recovery, or recapture device...), or (d): (i) For a combustion, recovery, or recapture device being used to comply with a percent....1426; (ii) For a combustion device being used to comply with an outlet concentration limitation of § 63...

  7. 40 CFR 63.1430 - Process vent reporting and recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... flames are absent. (2) The following information when using a combustion, recovery, or recapture device...), or (d): (i) For a combustion, recovery, or recapture device being used to comply with a percent....1426; (ii) For a combustion device being used to comply with an outlet concentration limitation of § 63...

  8. 40 CFR 63.343 - Compliance provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (1) Composite mesh-pad systems. (i) During the initial performance test, the owner or operator of an... limitations in § 63.342 through the use of a composite mesh-pad system shall determine the outlet chromium... performance test and accept ±2 inches of water column from this value as the compliant range. (ii) On and...

  9. 40 CFR 63.343 - Compliance provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (1) Composite mesh-pad systems. (i) During the initial performance test, the owner or operator of an... limitations in § 63.342 through the use of a composite mesh-pad system shall determine the outlet chromium... performance test and accept ±2 inches of water column from this value as the compliant range. (ii) On and...

  10. Where do food desert residents buy most of their junk food? Supermarkets.

    PubMed

    Vaughan, Christine A; Cohen, Deborah A; Ghosh-Dastidar, Madhumita; Hunter, Gerald P; Dubowitz, Tamara

    2017-10-01

    To examine where residents in an area with limited access to healthy foods (an urban food desert) purchased healthier and less healthy foods. Food shopping receipts were collected over a one-week period in 2013. These were analysed to describe where residents shopped for food and what types of food they bought. Two low-income, predominantly African-American neighbourhoods with limited access to healthy foods in Pittsburgh, PA, USA. Two hundred and ninety-three households in which the primary food shoppers were predominantly female (77·8 %) and non-Hispanic black (91·1 %) adults. Full-service supermarkets were by far the most common food retail outlet from which food receipts were returned and accounted for a much larger proportion (57·4 %) of food and beverage expenditures, both healthy and unhealthy, than other food retail outlets. Although patronized less frequently, convenience stores were notable purveyors of unhealthy foods. Findings highlight the need to implement policies that can help to decrease unhealthy food purchases in full-service supermarkets and convenience stores and increase healthy food purchases in convenience stores.

  11. Automated Temperature Control with Adjusting Outlet Valve of Fuel in the Process of Cooking Palm Sugar

    NASA Astrophysics Data System (ADS)

    Aripin, H.; Hiron, Nurul; Priatna, Edvin; Busaeri, Nundang; Andang, Asep; Suhartono; Sabchevski, Svilen

    2018-04-01

    In this paper, a real-time temperature control system for coconut sugar cooking is presented. It is based on a thermocouple temperature sensor. The temperature in the closed evaporator is used as a control variable of the DC servo control system for opening and closing of a valve embedded in a gas burner. The output power level, which is necessary in order to reach the target temperature is controlled by the microcontroller ATMega328P. A circuit module for control of the valve and temperature sensors as well as software for data acquisition have been implemented. The test results show that the system properly stabilizes the temperature in the closed evaporator for coconut sugar cooking in the range from room temperature to 110°C. A set point can be reached and held with an accuracy of ±0.75°C at a temperature of 110°C for 60 minutes.

  12. The density of tobacco retailers in home and school environments and relationship with adolescent smoking behaviours in Scotland.

    PubMed

    Shortt, N K; Tisch, C; Pearce, J; Richardson, E A; Mitchell, R

    2016-01-01

    Neighbourhood retailing of tobacco products has been implicated in affecting smoking prevalence rates. Long-term smoking usually begins in adolescence and tobacco control strategies have often focused on regulating 'child spaces', such as areas in proximity to schools. This cross-sectional study examines the association between adolescent smoking behaviour and tobacco retail outlet density around home and school environments in Scotland. Data detailing the geographic location of every outlet registered to sell tobacco products in Scotland were acquired from the Scottish Tobacco Retailers Register and used to create a retail outlet density measure for every postcode. This measure was joined to individual responses of the Scottish Schools Adolescent Lifestyle and Substance Use Survey (n=20 446). Using logistic regression models, we explored the association between the density of retailers, around both home and school address, and smoking behaviours. Those living in the areas of highest density of retailers around the home environment had 53% higher odds of reporting having ever smoked (95% CI 1.27 to 1.85, p<0.001) and 47% higher odds of reporting current smoking (95% CI 1.13 to 1.91 p<0.01). Conversely, those attending schools in areas of highest retail density had lower odds of having ever smoked (OR 0.66, 95% CI 0.50 to 0.86 p<0.01) and lower odds of current smoking (OR 0.75, 95% CI 0.59 to 0.95, p<0.05). The density of tobacco retail outlets in residential neighbourhoods is associated with increased odds of both ever smoked and current smoking among adolescents in Scotland. Policymakers may be advised to focus on reducing the overall density of tobacco outlets, rather than concentrating on 'child spaces'. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Community Perspectives on Access to and Availability of Healthy Food in Rural, Low-Resource, Latino Communities

    PubMed Central

    Ramírez, A. Susana; Estrada, Erendira; Grassi, Kathleen; Nathan, Stephanie

    2016-01-01

    Introduction Attention has focused on the food environment as a result of the growing concern with obesity rates among Latinos in rural areas. Researchers have observed associations between a lack of physical access to affordable produce in areas where supermarkets and grocery stores are limited and poor dietary intake and obesity; these associations are high in rural, low-resource neighborhoods with a high population of Latino residents. We aimed to engage residents of low-resource, Latino-majority neighborhoods in discussions of food access in a rural yet agricultural community setting, which is typically described as a “food desert.” Methods We used a mixed-methods approach and conducted 3 focus groups (n = 20) and in-depth interviews (n = 59) and surveys (n = 79) with residents of a rural yet agricultural community. We used thematic analysis to explore residents’ perceptions of access to healthy foods. Results Residents (n = 79; mean age, 41.6 y; 72% female; 79% Latino; 53% Spanish-speaking) reported that dollar and discount stores in this agricultural area provided access to produce; however, produce at retail stores was less affordable than produce at nonretail outlets such as fruit and vegetable stands. Gifts and trades of fruits and vegetables from neighbors and community organizations supplied no-cost or low-cost healthy foods. Residents’ suggestions to improve food access centered on lowering the cost of produce in existing retail outlets and seeking out nonretail outlets. Conclusion Our findings contribute to understanding of the food environment in low-resource, rural yet agricultural areas. Although such areas are characterized as “food deserts,” residents identified nonretail outlets as a viable source of affordable produce, while indicating that the cost of retail produce was a concern. Innovative policy solutions to increase healthy food consumption must focus on affordability as well as accessibility, and consider alternate, nonretail food outlets in agricultural areas. PMID:27978407

  14. Community Perspectives on Access to and Availability of Healthy Food in Rural, Low-Resource, Latino Communities.

    PubMed

    Valdez, Zulema; Ramírez, A Susana; Estrada, Erendira; Grassi, Kathleen; Nathan, Stephanie

    2016-12-15

    Attention has focused on the food environment as a result of the growing concern with obesity rates among Latinos in rural areas. Researchers have observed associations between a lack of physical access to affordable produce in areas where supermarkets and grocery stores are limited and poor dietary intake and obesity; these associations are high in rural, low-resource neighborhoods with a high population of Latino residents. We aimed to engage residents of low-resource, Latino-majority neighborhoods in discussions of food access in a rural yet agricultural community setting, which is typically described as a "food desert." We used a mixed-methods approach and conducted 3 focus groups (n = 20) and in-depth interviews (n = 59) and surveys (n = 79) with residents of a rural yet agricultural community. We used thematic analysis to explore residents' perceptions of access to healthy foods. Residents (n = 79; mean age, 41.6 y; 72% female; 79% Latino; 53% Spanish-speaking) reported that dollar and discount stores in this agricultural area provided access to produce; however, produce at retail stores was less affordable than produce at nonretail outlets such as fruit and vegetable stands. Gifts and trades of fruits and vegetables from neighbors and community organizations supplied no-cost or low-cost healthy foods. Residents' suggestions to improve food access centered on lowering the cost of produce in existing retail outlets and seeking out nonretail outlets. Our findings contribute to understanding of the food environment in low-resource, rural yet agricultural areas. Although such areas are characterized as "food deserts," residents identified nonretail outlets as a viable source of affordable produce, while indicating that the cost of retail produce was a concern. Innovative policy solutions to increase healthy food consumption must focus on affordability as well as accessibility, and consider alternate, nonretail food outlets in agricultural areas.

  15. On the nature of real and perceived bias in the mainstream media

    PubMed Central

    2018-01-01

    News consumers expect news outlets to be objective and balanced in their reports of events and opinions. However, there is a growing body of evidence of bias in the media caused by underlying political and socio-economic viewpoints. Previous studies have tried to classify the partiality of the media, but there is little work on quantifying it, and less still on the nature of this partiality. The vast amount of content published in social media enables us to quantify the inclination of the press to pre-defined sides of the socio-political spectrum. To describe such tendencies, we use tweets to automatically compute a news outlet’s political and socio-economic orientation. Results show that the media have a measurable bias, and illustrate this by showing the favoritism of Chilean media for the ruling political parties in the country. This favoritism becomes clearer as we empirically observe a shift in the position of the mass media when there is a change in government. Even though relative differences in bias between news outlets can be observed, public awareness of the bias of the media landscape as a whole appears to be limited by the political space defined by the news that we receive as a population. We found that the nature of the bias is reflected in the vocabulary used and the entities mentioned by different news outlets. A survey conducted among news consumers confirms that media bias has an impact on the coverage of controversial topics and that this is perceivable by the general audience. Having a more accurate method to measure and characterize media bias will help readers position outlets in the socio-economic landscape, even when a (sometimes opposite) self-declared position is stated. This will empower readers to better reflect on the content provided by their news outlets of choice. PMID:29570710

  16. Effects of spray drying on antioxidant capacity and anthocyanidin content of blueberry by-products.

    PubMed

    Lim, Kar; Ma, Mitzi; Dolan, Kirk D

    2011-09-01

    The effect of spray drying on degradation of nutraceutical components in cull blueberry extract was investigated. Samples collected before and after spray drying were tested for antioxidant capacity using oxygen radical absorbance capacity (ORAC(FL) ) and total phenolics; and for individual anthocyanidins. In Study 1, four different levels of maltodextrin (blueberry solids to maltodextrin ratios of 5: 95, 10: 90, 30: 70, and 50: 50) were spray dried a pilot-scale spray dryer. There was significantly higher retention of nutraceutical components with increased levels of maltodextrin indicating a protective effect of maltodextrin on the nutraceutical components during spray drying. In Study 2, the air inlet temperature of the spray dryer was kept constant for all runs at 150 °C, with 2 different outlet temperatures of 80 and 90 °C. The degradation of nutraceutical components was not significantly different at the 2 selected outlet temperatures. ORAC(FL) reduction for blueberry samples after spray drying was 66.3% to 69.6%. After spray drying, total phenolics reduction for blueberry was 8.2% to 17.5%. Individual anthocyanidin reduction for blueberry was 50% to 70%. The experimental spray dried powders compared favorably to commercial blueberry powders. Results of the study show that use of blueberry by-products is feasible to make a value-added powder. Results can be used by producers to estimate final nutraceutical content of spray-dried blueberry by-products. © 2011 Institute of Food Technologists®

  17. Characterizing pressure issues due to turbulent flow in tubing, in ultra-fast chiral supercritical fluid chromatography at up to 580bar.

    PubMed

    Berger, Terry A

    2016-12-02

    It has been widely suggested that the outlet pressure be changed to maintain constant density ("isopycnic" conditions) when comparing the kinetic performance of different columns in supercritical fluid chromatography (SFC). However, at high flow rates, flow in the tubing is turbulent, causing large extra-column pressure drops that limit options for changing outlet pressure. Some of these pressure drops occur before and some after the column, obscuring the actual column inlet and outlet pressures. In this work, a 4.6×100mm, 1.8μm R,R-Whelk-O1 column was used with low dispersion LD (120μm) plumbing to generate sub-1min chiral separations. However, the optimum, or near optimum, flow rate was 5mL-min -1 , producing a system pressure of 580bar (with 40% methanol, outlet pressure 120bar). Both the flow rate and pump pressure required were near the limits of the instrument, and significantly exceeded the capability of many other SFC's. Extra-column pressure drops (ΔP ec ) were as high as 200bar, caused mostly by turbulent flow in the tubing. The ΔP ec increased by more than the square of the flow rate. Reynolds Numbers (Re) were calculated for tubing as a function of flow rate between 100 and 400bar and 5-20% methanol in CO 2 , and 40°-60°C. This represents the most extensive analysis of turbulence in tubing in the SFC literature. Flow in 120μm ID tubing was calculated to be laminar below 1.0mL-min -1 , mostly transitional up to 2.5mL-min -1 and virtually always turbulent at 3mL-min -1 and higher. Flow in 170μm tubing is turbulent at lower flows but generates half the ΔP ec due to the lower mobile phase linear velocity. The results suggest that, while sub-minute chromatograms are easily generated, 4.6mm columns are not very user friendly for use with sub-2μm packings. The high flow rates required just to reach optimum result in high ΔP ec generated by the tubing, causing uncertainty in the true column inlet, outlet, and average column pressure/density. When comparing kinetic performance of columns with different dimensions, the pressure drops in the tubing must be considered. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. The premises is the premise: understanding off- and on-premises alcohol sales outlets to improve environmental alcohol prevention strategies.

    PubMed

    Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M; Wright, Annie

    2011-06-01

    Environmental strategies to prevent the misuse of alcohol among youth--e.g., use of public policies to restrict minors' access to alcohol--have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings.

  19. The Premises is the Premise: Understanding Off- and On-Premises Alcohol Sales Outlets to Improve Environmental Alcohol Prevention Strategies

    PubMed Central

    Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M.; Wright, Patricia Ann

    2017-01-01

    Environmental strategies to prevent the misuse of alcohol among youth—e.g., use of public policies to restrict minors’ access to alcohol—have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings. PMID:21373877

  20. 16. VIEW OF HIGHLINE CANAL PIPELINE OUTLET, SHOWING THE OUTLET, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. VIEW OF HIGHLINE CANAL PIPELINE OUTLET, SHOWING THE OUTLET, A GROUNDWATER PUMP (LEFT), AND THE SOUTH BRANCH OF THE CANAL (FOREGROUND), August 1989 - Highline Canal & Pumping Station, South side of Salt River between Tempe, Phoenix & Mesa, Tempe, Maricopa County, AZ

  1. 6. VIEW OF OUTLET GATE WHEEL AND STEM, WITH OUTLET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF OUTLET GATE WHEEL AND STEM, WITH OUTLET CHANNEL IN BACKGROUND, LOOKING SOUTHEAST - High Mountain Dams in Upalco Unit, Island Lake Dam, Ashley National Forest, 4.8 miles North of Miners Gulch Campground, Mountain Home, Duchesne County, UT

  2. Out-of-home food outlets and area deprivation: case study in Glasgow, UK

    PubMed Central

    Macintyre, Sally; McKay, Laura; Cummins, Steven; Burns, Cate

    2005-01-01

    Background There is a popular belief that out-of-home eating outlets, which typically serve energy dense food, may be more commonly found in more deprived areas and that this may contribute to higher rates of obesity and related diseases in such areas. Methods We obtained a list of all 1301 out-of-home eating outlets in Glasgow, UK, in 2003 and mapped these at unit postcode level. We categorised them into quintiles of area deprivation using the 2004 Scottish Index of Multiple Deprivation and computed mean density of types of outlet (restaurants, fast food restaurants, cafes and takeaways), and all types combined, per 1000 population. We also estimated odds ratios for the presence of any outlets in small areas within the quintiles. Results The density of outlets, and the likelihood of having any outlets, was highest in the second most affluent quintile (Q2) and lowest in the second most deprived quintile (Q4). Mean outlets per 1,000 were 4.02 in Q2, 1.20 in Q4 and 2.03 in Q5. With Q2 as the reference, Odds Ratios for having any outlets were 0.52 (CI 0.32–0.84) in Q1, 0.50 (CI 0.31 – 0.80) in Q4 and 0.61 (CI 0.38 – 0.98) in Q5. Outlets were located in the City Centre, West End, and along arterial roads. Conclusion In Glasgow those living in poorer areas are not more likely to be exposed to out-of-home eating outlets in their neighbourhoods. Health improvement policies need to be based on empirical evidence about the location of fast food outlets in specific national and local contexts, rather than on popular 'factoids'. PMID:16248898

  3. Determinants of price setting decisions on anti-malarial drugs at retail shops in Cambodia.

    PubMed

    Patouillard, Edith; Hanson, Kara; Kleinschmidt, Immo; Palafox, Benjamin; Tougher, Sarah; Pok, Sochea; O'Connell, Kate; Goodman, Catherine

    2015-05-30

    In many low-income countries, the private commercial sector plays an important role in the provision of malaria treatment. However, the quality of care it provides is often poor, with artemisinin combination therapy (ACT) generally being too costly for consumers. Decreasing ACT prices is critical for improving private sector treatment outcomes and reducing the spread of artemisinin resistance. Yet limited evidence exists on the factors influencing retailers' pricing decisions. This study investigates the determinants of price mark-ups on anti-malarial drugs in retail outlets in Cambodia. Taking an economics perspective, the study tests the hypothesis that the structure of the anti-malarial market determines the way providers set their prices. Providers facing weak competition are hypothesized to apply high mark-ups and set prices above the competitive level. To analyse the relationship between market competition and provider pricing, the study used cross-sectional data from retail outlets selling anti-malarial drugs, including outlet characteristics data (e.g. outlet type, anti-malarial sales volumes), range of anti-malarial drugs stocked (e.g. dosage form, brand status) and purchase and selling prices. Market concentration, a measure of the level of market competition, was estimated using sales volume data. Market accessibility was defined based on travel time to the closest main commercial area. Percent mark-ups were calculated using price data. The relationship between mark-ups and market concentration was explored using regression analysis. The anti-malarial market was on average highly concentrated, suggesting weak competition. Higher concentration was positively associated with higher mark-ups in moderately accessible markets only, with no significant relationship or a negative relationship in other markets. Other determinants of pricing included anti-malarial brand status and generic type, with higher mark-ups on cheaper products. The results indicate that provider pricing as well as other key elements of anti-malarial supply and demand may have played an important role in the limited access to appropriate malaria treatment in Cambodia. The potential for an ACT price subsidy at manufacturer level combined with effective communications directed at consumers and supportive private sector regulation should be explored to improve access to quality malaria treatment in Cambodia.

  4. Thermodynamic Analysis of the Use a Chemical Heat Pump to Link a Supercritical Water-Cooled Nuclear Reactor and a Thermochemical Water-Splitting Cycle for Hydrogen Production

    NASA Astrophysics Data System (ADS)

    Granovskii, Mikhail; Dincer, Ibrahim; Rosen, Marc A.; Pioro, Igor

    Increases in the power generation efficiency of nuclear power plants (NPPs) are mainly limited by the permissible temperatures in nuclear reactors and the corresponding temperatures and pressures of the coolants in reactors. Coolant parameters are limited by the corrosion rates of materials and nuclear-reactor safety constraints. The advanced construction materials for the next generation of CANDU reactors, which employ supercritical water (SCW) as a coolant and heat carrier, permit improved “steam” parameters (outlet temperatures up to 625°C and pressures of about 25 MPa). An increase in the temperature of steam allows it to be utilized in thermochemical water splitting cycles to produce hydrogen. These methods are considered by many to be among the most efficient ways to produce hydrogen from water and to have advantages over traditional low-temperature water electrolysis. However, even lower temperature water splitting cycles (Cu-Cl, UT-3, etc.) require an intensive heat supply at temperatures higher than 550-600°C. A sufficient increase in the heat transfer from the nuclear reactor to a thermochemical water splitting cycle, without jeopardizing nuclear reactor safety, might be effectively achieved by application of a heat pump, which increases the temperature of the heat supplied by virtue of a cyclic process driven by mechanical or electrical work. Here, a high-temperature chemical heat pump, which employs the reversible catalytic methane conversion reaction, is proposed. The reaction shift from exothermic to endothermic and back is achieved by a change of the steam concentration in the reaction mixture. This heat pump, coupled with the second steam cycle of a SCW nuclear power generation plant on one side and a thermochemical water splitting cycle on the other, increases the temperature of the “nuclear” heat and, consequently, the intensity of heat transfer into the water splitting cycle. A comparative preliminary thermodynamic analysis is conducted of the combined system comprising a SCW nuclear power generation plant and a chemical heat pump, which provides high-temperature heat to a thermochemical water splitting cycle for hydrogen production. It is concluded that the proposed chemical heat pump permits the utilization efficiency of nuclear energy to be improved by at least 2% without jeopardizing nuclear reactor safety. Based on this analysis, further research appears to be merited on the proposed advanced design of a nuclear power generation plant combined with a chemical heat pump, and implementation in appropriate applications seems worthwhile.

  5. Spatial distribution of the phytoplankton in the White Sea during atypical domination of dinoflagellates (July 2009)

    NASA Astrophysics Data System (ADS)

    Ilyash, L. V.; Zhitina, L. S.; Belevich, T. A.; Shevchenko, V. P.; Kravchishina, M. D.; Pantyulin, A. N.; Tolstikov, A. V.; Chultsova, A. L.

    2016-05-01

    The species composition and biomass of phytoplankton, concentrations of chlorophyll a (Chl a) and nutrients, and accompanying hydrophysical conditions have been studied in the White Sea on July 6-11, 2009. The temperature of the surface water layer was lower than the multiyear average in July. Dinoflagellates dominated in the entire studied area; this was not the typical event for July. We suggest that domination of dinoflagellates was caused by low water temperature, when the nutrient regeneration rate was insufficient to support diatom growth. The abundance of microalgae and the structure of the phytoplankton community depended on the water structure. Variations in the phytoplankton community structure were caused not by substitution of specific species but rather by variability of the abundance of a single species, Heterocapsa triquetra. The highest phytoplankton biomass has been recorded in weakly stratified waters, where tidal mixing supplied the income of inorganic nutrients. The income of nutrients to the photic layer was limited in the stratified waters of Dvina Bay during the summer low-water period, so the phytoplankton abundance was low. We suggest that the lens of surface desalinated water presumably originated from the outlet of the Dvina River was registered in the central part of the White Sea.

  6. Effect of Air Cooling of Turbine Disk on Power and Efficiency of Turbine from Turbo Engineering Corporation TT13-18 Turbosupercharger.

    NASA Technical Reports Server (NTRS)

    Berkey, William E.

    1949-01-01

    An investigation was conducted to determine the effect of turbine-disk cooling with air on the efficiency and the power output of the radial-flow turbine from the Turbo Engineering Corporation TT13-18 turbosupercharger. The turbine was operated at a constant range of ratios of turbine-inlet total pressure to turbine-outlet static pressure of 1,5 and 2.0, turbine-inlet total pressure of 30 inches mercury absolute, turbine-inlet total temperature of 12000 to 20000 R, and rotor speeds of 6000 to 22,000 rpm, Over the normal operating range of the turbine, varying the corrected cooling-air weight flow from approximately 0,30 to 0.75 pound per second produced no measurable effect on the corrected turbine shaft horsepower or the turbine shaft adiabatic efficiency. Varying the turbine-inlet total temperature from 12000 to 20000 R caused no measurable change in the corrected cooling-air weight flow. Calculations indicated that the cooling-air pumping power in the disk passages was small and was within the limits of the accuracy of the power measurements. For high turbine power output, the power loss to the compressor for compressing the cooling air was approximately 3 percent of the total turbine shaft horsepower.

  7. Research of a possibility of receiving sorbents for a sewage disposal from a wastage of coal preparation factory

    NASA Astrophysics Data System (ADS)

    Buyantuev, S. L.; Kondratenko, A. S.; Shishulkin, S. Y.; Stebenkova, Y. Y.; Khmelev, A. B.

    2017-05-01

    The paper presents the results of the studies of the structure and porosity of the coal cake processed by electric arc plasma. The main limiting factor in processing of coal cakes sorbents is their high water content. As a result of coal washing, the main share of water introduced into the cake falls on hard-hydrate and colloidal components. This makes impossible application of traditional processes of manufacturing from a cake of coal sorbents. Using the electric arc intensifies the processes of thermal activation of coal cakes associated with thermal shock, destruction and vapor-gas reactions occurring at the surfaces of the particles at an exposure temperature of up to 3000 °C, which increases the title product outlet (sorbent) and thereby reduces manufacturing costs and improves environmental performance. The investigation of the thermal activation zone is carried out in the plasma reactor chamber by thermal imaging method followed by mapping-and 3D-modeling of temperature fields. the most important physical and chemical properties of the sorbents from coal cake activated by plasma was studied. The obtained results showed the possibility of coal cake thermal activation by electric arc plasma to change its material composition, the appearance of porosity and associated sorption capacity applied for wastewater treatment.

  8. Supercharging an internal combustion engine by aid of a dual-rotor bi-flux axial compressor

    NASA Astrophysics Data System (ADS)

    Grǎdinariu, Andrei Cristian; Mihai, Ioan

    2016-12-01

    Internal combustion engines can be supercharged in order to enhance their performances [1-3]. Engine power is proportional to the quantity of fresh fluid introduced into the cylinder. At present, the general tendency is to try to obtain actual specific powers as high as possible, for as small as possible cylinder capacity, without increasing the generated pollution hazards. The present paper investigates the impact of replacing a centrifugal turbo-compressor with an axial double-rotor bi-flux one [4]. The proposed method allows that for the same number of cylinders, an increase in discharged airflow, accompanied by a decrease in fuel consumption. Using a program developed under the MathCad environment, the present work was aimed at studying the way temperature modifies at the end of isentropic compression under supercharging conditions. Taking into account a variation between extreme limits of the ambient temperature, its influence upon the evolution of thermal load coefficient was analyzed considering the air pressure at the compressor cooling system outlet. This analysis was completed by an exergetical study of the heat evacuated through cylinder walls in supercharged engine conditions. The conducted investigation allows verification of whether significant differences can be observed between an axial, dual-rotor, bi-flux compressor and centrifugal compressors.

  9. Microtopographic control on the ground thermal regime in ice wedge polygons

    NASA Astrophysics Data System (ADS)

    Abolt, Charles J.; Young, Michael H.; Atchley, Adam L.; Harp, Dylan R.

    2018-06-01

    The goal of this research is to constrain the influence of ice wedge polygon microtopography on near-surface ground temperatures. Ice wedge polygon microtopography is prone to rapid deformation in a changing climate, and cracking in the ice wedge depends on thermal conditions at the top of the permafrost; therefore, feedbacks between microtopography and ground temperature can shed light on the potential for future ice wedge cracking in the Arctic. We first report on a year of sub-daily ground temperature observations at 5 depths and 9 locations throughout a cluster of low-centered polygons near Prudhoe Bay, Alaska, and demonstrate that the rims become the coldest zone of the polygon during winter, due to thinner snowpack. We then calibrate a polygon-scale numerical model of coupled thermal and hydrologic processes against this dataset, achieving an RMSE of less than 1.1 °C between observed and simulated ground temperature. Finally, we conduct a sensitivity analysis of the model by systematically manipulating the height of the rims and the depth of the troughs and tracking the effects on ice wedge temperature. The results indicate that winter temperatures in the ice wedge are sensitive to both rim height and trough depth, but more sensitive to rim height. Rims act as preferential outlets of subsurface heat; increasing rim size decreases winter temperatures in the ice wedge. Deeper troughs lead to increased snow entrapment, promoting insulation of the ice wedge. The potential for ice wedge cracking is therefore reduced if rims are destroyed or if troughs subside, due to warmer conditions in the ice wedge. These findings can help explain the origins of secondary ice wedges in modern and ancient polygons. The findings also imply that the potential for re-establishing rims in modern thermokarst-affected terrain will be limited by reduced cracking activity in the ice wedges, even if regional air temperatures stabilize.

  10. Neighborhood deprivation and access to fast-food retailing: a national study.

    PubMed

    Pearce, Jamie; Blakely, Tony; Witten, Karen; Bartie, Phil

    2007-05-01

    Obesogenic environments may be an important contextual explanation for the growing obesity epidemic, including its unequal social distribution. The objective of this study was to determine whether geographic access to fast-food outlets varied by neighborhood deprivation and school socioeconomic ranking, and whether any such associations differed to those for access to healthier food outlets. Data were collected on the location of fast-food outlets, supermarkets, and convenience stores across New Zealand. The data were geocoded and geographic information systems used to calculate travel distances from each census meshblock (i.e., neighborhood), and each school, to the closest fast-food outlet. Median travel distances are reported by a census-based index of socioeconomic deprivation for each neighborhood, and by a Ministry of Education measure of socioeconomic circumstances for each school. Analyses were repeated for outlets selling healthy food to allow comparisons. At the national level, statistically significant negative associations were found between neighborhood access to the nearest fast-food outlet and neighborhood deprivation (p<0.001) for both multinational fast-food outlets and locally operated outlets. The travel distances to both types of fast food outlet were at least twice as far in the least socially deprived neighborhoods compared to the most deprived neighborhoods. A similar pattern was found for outlets selling healthy food such as supermarkets and smaller food outlets (p<0.001). These relationships were broadly linear with travel distances tending to be shorter in more-deprived neighborhoods. There is a strong association between neighborhood deprivation and geographic access to fast food outlets in New Zealand, which may contribute to the understanding of environmental causes of obesity. However, outlets potentially selling healthy food (e.g., supermarkets) are patterned by deprivation in a similar way. These findings highlight the importance of considering all aspects of the food environment (healthy and unhealthy) when developing environmental strategies to address the obesity epidemic.

  11. A longitudinal analysis of alcohol outlet density and assault.

    PubMed

    Livingston, Michael

    2008-06-01

    The majority of studies that have examined the local-level relationship between alcohol outlet density and violence have utilized cross-sectional data. These studies have consistently demonstrated that there is a spatial link between outlets and violence, but because of their design they have not been able to determine whether changes in outlet density result in changes in rates of violence. The few studies that have examined this question over time have found that the violence rates are related to changes in outlet density. This study provides further evidence of this link and examines the characteristics of regions in which changes in outlet density are most strongly associated with changes in violence rates. The study examined 9 years of data measuring alcohol outlet density (using liquor licensing records) and alcohol-related violence (using police recorded night-time assaults) from 186 postcodes in the metropolitan area of Melbourne, Australia. The relationships between 3 types of alcohol outlet density and alcohol-related violence were assessed using fixed-effects models. The postcodes were then grouped into 5 clusters based on their socio-demographic profile and separate fixed-effects models were fitted to assess whether the relationships between outlets and violence differed based on the type of region being examined. The initial models found overall positive relationships between all 3 types of alcohol outlets and violence. When separate models were developed for postcode clusters, they demonstrated that the link between outlet density and violence was significant in all neighborhood types, but the specific relationships varied substantially. Changes in the number of alcohol outlets in a community are linked to changes in the amount of violence the community experiences. This relationship varies across the clusters of suburbs examined, with packaged liquor outlets consistently associated with violence in suburban areas and general (hotel) and on-premise (nightclubs, restaurants, and bars) licenses associated with violence in inner-city and inner-suburban areas.

  12. Spatial accessibility to physical activity facilities and to food outlets and overweight in French youth.

    PubMed

    Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C

    2012-07-01

    Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Cross-sectional study. 3293 students, aged 12 ± 0.6 years, randomly selected from eastern France middle schools. Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25-2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20-2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio-economically disadvantaged youth. These data should be relevant for influencing health policies and urban planning at both a national and local level.

  13. 40 CFR 86.884-8 - Dynamometer and engine equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...), turbocharger outlet(s), exhaust aftertreatment device(s), or crossover junction (on Vee engines), whichever is... manifold, turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For... smoke levels 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust...

  14. 40 CFR 86.884-8 - Dynamometer and engine equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...), turbocharger outlet(s), exhaust aftertreatment device(s), or crossover junction (on Vee engines), whichever is... manifold, turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For... smoke levels 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust...

  15. 40 CFR 86.884-8 - Dynamometer and engine equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...), turbocharger outlet(s), exhaust aftertreatment device(s), or crossover junction (on Vee engines), whichever is... manifold, turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For... smoke levels 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust...

  16. 40 CFR 86.884-8 - Dynamometer and engine equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...), turbocharger outlet(s), exhaust aftertreatment device(s), or crossover junction (on Vee engines), whichever is... manifold, turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For... smoke levels 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust...

  17. 40 CFR 63.453 - Monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... outlet total HAP or methanol concentration, as an alternative to monitoring thermal oxidizer operating... operated to measure the methanol outlet concentration to comply with the steam stripper outlet... requirements specified in paragraphs (j)(1)(ii)(A) and (B) of this section. (A) Obtain daily inlet and outlet...

  18. 40 CFR 63.453 - Monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... outlet total HAP or methanol concentration, as an alternative to monitoring thermal oxidizer operating... operated to measure the methanol outlet concentration to comply with the steam stripper outlet... requirements specified in paragraphs (j)(1)(ii)(A) and (B) of this section. (A) Obtain daily inlet and outlet...

  19. Assessing the relationship between alcohol outlets and domestic violence: routine activities and the neighborhood environment.

    PubMed

    Roman, Caterina G; Reid, Shannon E

    2012-01-01

    Studies have consistently found a positive relationship between alcohol outlet density and assault, but only a handful of studies have examined whether outlet density has an influence on domestic violence. Using a framework based in crime opportunity theories, this study estimates spatial econometric regression models to test whether the density of alcohol outlets across neighborhoods is positively associated with police calls for service for domestic violence. Models also were developed to test whether the relationships found were consistent across time periods associated with the use of alcohol outlets (weeknights and weekends). The findings indicate that off-premise outlets were associated with a significant increase in domestic violence, but on-premise outlets (specifically restaurants and nightclubs) were associated with a decrease in domestic violence. The risk for domestic violence in areas of high densities of off-premise outlets was found to be high during the weekend but not during the weeknight, suggesting different routine activities for domestic violence offenders during the week.

  20. Retail availability and marketing of electronic cigarettes in Canada.

    PubMed

    Hammond, David; White, Christine M; Czoli, Christine D; Martin, Christina L; Magennis, Paul; Shiplo, Samantha

    2015-10-09

    Canada is among an increasing number of countries with restrictions on the sale of electronic cigarettes (e-cigarettes). In Canada, e-cigarettes containing nicotine have not been approved for sale; however, e-cigarettes that do not contain nicotine and do not make health claims can be sold. To date, there is little empirical evidence assessing the retail availability and marketing of e-cigarettes in countries such as Canada. Audits were conducted at 59 brick-and-mortar retail outlets (grocery stores, convenience stores, tobacconist shops and vape shops) in four cities (Vancouver, Toronto, Montreal and Halifax) in August-October 2014. In addition, a total of 21 e-cigarette manufacturer/retailer websites were audited, and inquiries were made as to whether the companies sold nicotine-containing products. Overall, 76% of the retail outlets sold e-cigarette products. Of convenience stores, grocery stores and tobacconist shops with e-cigarettes for sale, the vast majority (94%) sold nicotine-free products only; in contrast, all the vape shops sold at least one nicotine-containing e-cigarette product. Front counter displays were the most common form of in-store promotions and were present in virtually all convenience stores, tobacconist shops and vape shops. Nicotine-containing e-cigarettes were available for purchase at approximately half (52%) of the online e-cigarette retailers surveyed. E-cigarettes with and without nicotine are widely available and marketed at a variety of retail outlets in Canada. "Illegal" sales of nicotinecontaining e-cigarettes were predominantly found at vape shops and online outlets, suggesting limited compliance with existing regulations.

  1. Groundwater age, life expectancy and transit time distributions in advective dispersive systems; 2. Reservoir theory for sub-drainage basins

    NASA Astrophysics Data System (ADS)

    Cornaton, F.; Perrochet, P.

    2006-09-01

    Groundwater age and life expectancy probability density functions (pdf) have been defined, and solved in a general three-dimensional context by means of forward and backward advection-dispersion equations [Cornaton F, Perrochet P. Groundwater age, life expectancy and transit time distributions in advective-dispersive systems; 1. Generalized reservoir theory. Adv Water Res (xxxx)]. The discharge and recharge zones transit time pdfs were then derived by applying the reservoir theory (RT) to the global system, thus considering as ensemble the union of all inlet boundaries on one hand, and the union of all outlet boundaries on the other hand. The main advantages in using the RT to calculate the transit time pdf is that the outlet boundary geometry does not represent a computational limiting factor (e.g. outlets of small sizes), since the methodology is based on the integration over the entire domain of each age, or life expectancy, occurrence. In the present paper, we extend the applicability of the RT to sub-drainage basins of groundwater reservoirs by treating the reservoir flow systems as compartments which transfer the water fluxes to a particular discharge zone, and inside which mixing and dispersion processes can take place. Drainage basins are defined by the field of probability of exit at outlet. In this way, we make the RT applicable to each sub-drainage system of an aquifer of arbitrary complexity and configuration. The case of the well-head protection problem is taken as illustrative example, and sensitivity analysis of the effect of pore velocity variations on the simulated ages is carried out.

  2. Source model of volcanic tremor: two-phase flow instability in a pipe-valve system

    NASA Astrophysics Data System (ADS)

    Fujita, E.

    2003-12-01

    Volcanic tremor at a shallow depth beneath the volcano is inferred to link to hydrothermal activities powered by heat supply from magma. In this study, we developed numerical simulations of the instabilities of the water-steam two-phase flow in a pipe-valve system and considered the source mechanism of volcanic tremor. The experiments of two-phase flow by Veziroglu and Lee [1968] revealed the two kinds of oscillating modes, density wave oscillation with the period of a few seconds and pressure drop oscillation with the period of dozens of seconds. These modes were mainly controlled by the pressure difference between inlet and outlet, flux rate of fluid and heat supply rate. Especially, the former mode appears when the flux rate is small and the latter does when the pressure difference and heat supply rate are larger. We performed some preliminary numerical simulation of these oscillations in water-steam flow in a cylindrical conduit. As an example, we assume the flow in conduit of 4 m length with the valves at inlet and outlet with the conditions of non-slip at the wall. As initial conditions, the inlet and outlet pressures are fixed to be 1.2E5 Pa and 1.0E5 Pa, respectively, water temperature of 370 K, heat supply of 1.0E6 - 2.0E7W/m3. The friction except the valve area is assumed to be 1000kg/m3. After the heating condition becomes stable, we shut the valve at the outlet and detect the significant oscillation. In case of the heat supply of 1.1E7W/m3, density drop oscillation with the period of 0.16s has appeared. In this model, the oscillation originates from the density change due to vaporization, and its information arrives at the outlet with the velocity of two-phase flow. The cycle of heating and boiling controls the interval of the tremor occurrence and the period is determined by the length of the pipe and the flow velocity. The shut of valve physically corresponds to geometrical narrowing, choking, and non-linear effect of flow and/or surrounding medium.

  3. Solid oxide fuel cell with monolithic core

    DOEpatents

    McPheeters, Charles C.; Mrazek, Franklin C.

    1988-01-01

    A solid oxide fuel cell in which fuel and oxidant gases undergo an electrochemical reaction to produce an electrical output includes a monolithic core comprised of a corrugated conductive sheet disposed between upper and lower generally flat sheets. The corrugated sheet includes a plurality of spaced, parallel, elongated slots which form a series of closed, linear, first upper and second lower gas flow channels with the upper and lower sheets within which a fuel gas and an oxidant gas respectively flow. Facing ends of the fuel cell are generally V-shaped and provide for fuel and oxidant gas inlet and outlet flow, respectively, and include inlet and outlet gas flow channels which are continuous with the aforementioned upper fuel gas and lower oxidant gas flow channels. The upper and lower flat sheets and the intermediate corrugated sheet are preferably comprised of ceramic materials and are securely coupled together such as by assembly in the green state and sintering together during firing at high temperatures. A potential difference across the fuel cell, or across a stacked array of similar fuel cells, is generated when an oxidant gas such as air and a fuel such as hydrogen gas is directed through the fuel cell at high temperatures, e.g., between 700.degree. C. and 1100.degree. C.

  4. Solid oxide fuel cell with monolithic core

    DOEpatents

    McPheeters, C.C.; Mrazek, F.C.

    1988-08-02

    A solid oxide fuel cell in which fuel and oxidant gases undergo an electrochemical reaction to produce an electrical output includes a monolithic core comprised of a corrugated conductive sheet disposed between upper and lower generally flat sheets. The corrugated sheet includes a plurality of spaced, parallel, elongated slots which form a series of closed, linear, first upper and second lower gas flow channels with the upper and lower sheets within which a fuel gas and an oxidant gas respectively flow. Facing ends of the fuel cell are generally V-shaped and provide for fuel and oxidant gas inlet and outlet flow, respectively, and include inlet and outlet gas flow channels which are continuous with the aforementioned upper fuel gas and lower oxidant gas flow channels. The upper and lower flat sheets and the intermediate corrugated sheet are preferably comprised of ceramic materials and are securely coupled together such as by assembly in the green state and sintering together during firing at high temperatures. A potential difference across the fuel cell, or across a stacked array of similar fuel cells, is generated when an oxidant gas such as air and a fuel such as hydrogen gas is directed through the fuel cell at high temperatures, e.g., between 700 C and 1,100 C. 8 figs.

  5. 40 CFR 86.884-8 - Dynamometer and engine equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... appropriate type of smokemeter placed no more than 32 feet from the exhaust manifold(s), turbocharger outlet(s..., turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For engines with... 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust aftertreatment...

  6. 46 CFR 95.15-25 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...

  7. 46 CFR 193.15-25 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a) Discharge outlets...

  8. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  9. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  10. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  11. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  12. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  13. 46 CFR 95.15-25 - Discharge outlets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...

  14. 46 CFR 95.15-25 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...

  15. 46 CFR 193.15-25 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a) Discharge outlets...

  16. Research on Spent Fuel Storage and Transportation in CRIEPI (Part 2 Concrete Cask Storage)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koji Shirai; Jyunichi Tani; Taku Arai

    2008-10-01

    Concrete cask storage has been implemented in the world. At a later stage of storage period, the containment of the canister may deteriorate due to stress corrosion cracking phenomena in a salty air environment. High resistant stainless steels against SCC have been tested as compared with normal stainless steel. Taking account of the limited time-length of environment with certain level of humidity and temperature range, the high resistant stainless steels will survive from SCC damage. In addition, the adhesion of salt from salty environment on the canister surface will be further limited with respect to the canister temperature and anglemore » of the canister surface against the salty air flow in the concrete cask. Optional countermeasure against SCC with respect to salty air environment has been studied. Devices consisting of various water trays to trap salty particles from the salty air were designed to be attached at the air inlet for natural cooling of the cask storage building. Efficiency for trapping salty particles was evaluated. Inspection of canister surface was carried out using an optical camera inserted from the air outlet through the annulus of a concrete cask that has stored real spent fuel for more than 15 years. The camera image revealed no gross degradation on the surface of the canister. Seismic response of a full-scale concrete cask with simulated spent fuel assemblies has been demonstrated. The cask did not tip over, but laterally moved by the earthquake motion. Stress generated on the surface of the spent fuel assemblies during the earthquake motion were within the elastic region.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  18. Community organization moderates the effect of alcohol outlet density on violence.

    PubMed

    Pridemore, William Alex; Grubesic, Tony H

    2012-12-01

    There is growing evidence from multiple disciplines that alcohol outlet density is associated with community levels of assault. Based on the theoretical and empirical literatures on social organization and crime, we tested the hypothesis that the association between alcohol outlet density and neighbourhood violence rates is moderated by social organization. Using geocoded police data on assaults, geocoded data on the location of alcohol outlets, and controlling for several structural factors thought to be associated with violence rates, we tested this hypothesis employing negative binomial regression with our sample of 298 block groups in Cincinnati. Our results revealed direct effects of alcohol outlet density and social organization on assault density, and these effects held for different outlet types (i.e., off-premise, bars, restaurants) and levels of harm (i.e., simple and aggravated assaults). More importantly, we found that the strength of the outlet-assault association was significantly weaker in more socially organized communities. Subsequent analyses by level of organization revealed no effects of alcohol outlet density on aggravated assaults in organized block groups, but significant effects in disorganized block groups. We found no association between social (dis)organization and outlet density. These results clarify the community-level relationship between alcohol outlets and violence and have important implications for municipal-level alcohol policies. © London School of Economics and Political Science 2012.

  19. Ecological Associations of Alcohol Outlets with Underage and Young Adult Injuries

    PubMed Central

    Gruenewald, Paul J.; Freisthler, Bridget; Remer, Lillian; LaScala, Elizabeth A.; Treno, Andrew J.; Ponicki, William R.

    2010-01-01

    Objective This paper argues that associations between rates of three specific problems related to alcohol (i.e., accidents, traffic crashes, and assaults) should be differentially related to densities of off-premise outlets among underage youth and young adults based upon age related-patterns of alcohol outlet use. Methods Zip code-level population models assessed local and distal effects of alcohol outlets upon rates of hospital discharges for these outcomes. Results Densities of off-premise alcohol outlets were significantly related to injuries from accidents, assaults, and traffic crashes for both underage youth and young adults. Densities of bars were associated with more assaults and densities of restaurants were associated with more traffic crash injuries for young adults. Conclusions The distribution of alcohol-related injuries relative to alcohol outlets reflect patterns of alcohol outlet use. PMID:20028361

  20. From Medical to Recreational Marijuana Sales: Marijuana Outlets and Crime in an Era of Changing Marijuana Legislation.

    PubMed

    Freisthler, Bridget; Gaidus, Andrew; Tam, Christina; Ponicki, William R; Gruenewald, Paul J

    2017-06-01

    A movement from medical to recreational marijuana use allows for a larger base of potential users who have easier access to marijuana, because they do not have to visit a physician before using marijuana. This study examines whether changes in the density of marijuana outlets were related to violent, property, and marijuana-specific crimes in Denver, CO during a time in which marijuana outlets began selling marijuana for recreational, and not just medical, use. We collected data on locations of crimes, marijuana outlets and covariates for 481 Census block groups over 34 months (N = 16,354 space-time units). A Bayesian Poisson space-time model assessed statistical relationships between independent measures and crime counts within "local" Census block groups. We examined spatial "lag" effects to assess whether crimes in Census block groups adjacent to locations of outlets were also affected. Independent of the effects of covariates, densities of marijuana outlets were unrelated to property and violent crimes in local areas. However, the density of marijuana outlets in spatially adjacent areas was positively related to property crime in spatially adjacent areas over time. Further, the density of marijuana outlets in local and spatially adjacent blocks groups was related to higher rates of marijuana-specific crime. This study suggests that the effects of the availability of marijuana outlets on crime do not necessarily occur within the specific areas within which these outlets are located, but may occur in adjacent areas. Thus studies assessing the effects of these outlets in local areas alone may risk underestimating their true effects.

Top