SR-80 and US-191 oversize load study.
DOT National Transportation Integrated Search
2013-11-01
The purpose of the SR-80 and US-191 Oversize Load Study is to identify roadway conditions that restrict travel by oversize vehicles on the SR-80 and US-191 study routes. The study also recommends infrastructure and related improvements that will elim...
Accommodating oversize and overweight loads : technical report.
DOT National Transportation Integrated Search
2012-07-01
Adequate management of oversize/overweight (OS/OW) permit loads throughout the state of Texas is : critical to maintaining a vibrant state economy. The growth in the number and size of permit loads in recent : years is clear evidence that new tools a...
Accommodating Oversize and Overweight Loads : Instructor and Student Guide
DOT National Transportation Integrated Search
2012-08-01
This instructor and student guide is designed to guide the instructor in conveying information at the district level concerning Research Project 0-6404 Accommodating Oversize and Overweight Loads. The specific information focuses on the Bryan D...
Optimizing the analysis of routing oversize/overweight loads to provide efficient freight corridors.
DOT National Transportation Integrated Search
2012-07-01
The subject of this report is limited specifically to Kansas highways. Current features of the State : Highway System were looked at to determine corridors that do not limit Oversize/Overweight (OS/OW) : vehicles, or that limit loads to varying de...
DOT National Transportation Integrated Search
2012-07-01
The subject of this report is limited specifically to Kansas highways. Current features of the State Highway System were looked at to determine corridors that do not limit Oversize/Overweight (OS/OW) vehicles, or that limit loads to varying degree...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Eric; Withers, Chuck; McIlvaine, Janet
The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. Themore » problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.« less
NASA Astrophysics Data System (ADS)
Dawid, Rys; Piotr, Jaskula
2018-05-01
Oversized heavy duty vehicles occur in traffic very rarely but they reach extremely high weights, even up to 800 tonne. The detrimental impact of these vehicles on pavement structure is much higher than in case of commercial vehicles that comprise typical traffic, thus it is necessary to assess the sensitivity of pavement structure to passage of oversized vehicles. The paper presents results of sample calculations of load equivalency factor of a heavy duty oversized vehicle with usage of mechanistic-empirical approach. The effects of pavement thickness, type of distress (cracking or rutting) and pavement condition (new or old with structural damage) were considered in the paper. Analysis revealed that a single pass of an 800 tonne oversized vehicle is equivalent to pass of up to 377 standard 100 kN axles. Load equivalency factor calculated for thin structures is almost 3 times lower than for thick structures, however, the damage effect caused by one pass of an oversized vehicle is higher in the case of thin structure. Bearing capacity of a pavement structure may be qualified as sufficient for passage of an oversized heavy duty vehicle when the measured deflection, for example in an FWD test, does not exceed the maximum deflections derived from mechanistic-empirical analysis. The paper presents sample calculation of maximum deflections which allow to consider passage of an oversized vehicle as safe over different pavement structures. The paper provides road administration with a practical tool which helps to decide whether to issue a permit of passage for a given oversized vehicle.
NASA Astrophysics Data System (ADS)
Petru, Jan; Dolezel, Jiri; Krivda, Vladislav
2017-09-01
In the past the excessive and oversized loads were realized on selected routes on roads that were adapted to ensure smooth passage of transport. Over the years, keeping the passages was abandoned and currently there are no earmarked routes which would be adapted for such type of transportation. The routes of excessive and oversized loads are currently planned to ensure passage of the vehicle through the critical points on the roads. Critical points are level and fly-over crossings of roads, bridges, toll gates, traffic signs and electrical and other lines. The article deals with the probability assessment of selected critical points of the route of the excessive load on the roads of 1st class, in relation to ensuring the passage through the roundabout. The bases for assessing the passage of the vehicle with excessive load through a roundabout are long-term results of video analyses of monitoring the movement of transports on similar intersections and determination of the theoretical probability model of vehicle movement at selected junctions. On the basis of a virtual simulation of the vehicle movement at crossroads and using MonteCarlo simulation method vehicles’ paths are analysed and the probability of exit of the vehicle outside the crossroad in given junctions is quantified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2015-06-01
This NREL highlight describes a simulation-based study that analyzes the energy impacts of oversized residential air conditioners. Researchers found that, if parasitic power losses are minimal, there is very little increase in energy use for oversizing an air conditioner. The research demonstrates that new residential air conditioners can be sized primarily based on comfort considerations, because capacity typically has minimal impact on energy efficiency. The results of this research can be useful for contractors and homeowners when choosing a new air conditioner or heat pump during retrofits of existing homes. If the selected unit has a crankcase heater, performing propermore » load calculations to be sure the new unit is not oversized will help avoid excessive energy use.« less
Field Test of Boiler Primary Loop Temperature Controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glanville, P.; Rowley, P.; Schroeder, D.
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
PARR
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less
Impact of Trunnion Axle Groups on the Performance of Highway Infrastructure
DOT National Transportation Integrated Search
2001-03-01
The trunnion axle configuration has gained favor with many carriers of oversized and overweight loads. In addition, the frequency of interstate hauling of these specialized loads is increasing. The trunnion axle configuration allows for placement of ...
Low-Load Space Conditioning Needs Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puttagunta, Srikanth
Heating, ventilating, and air-conditioning (HVAC) equipment must be right-sized to ensure energy performance and comfort. With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment that creates system efficiency, comfort, and cost penalties. To bridge the gap between currently available HVAC equipment that is oversized or inefficient and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of the needs of the multifamily building and attached single-family (duplex and townhouse) home market. Over the past decade, Steven Winter Associates, Inc. (SWA) has providedmore » certification and consulting services for hundreds of housing projects and has accrued a large pool of data that describe multifamily and attached single-family home characteristics. The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) compiled and analyzed these data to outline the characteristics of low-load dwellings such as the heating and cooling design loads.« less
Assessment of the Effect of Blast Hole Diameter on the Number of Oversize Boulders Using ANN Model
NASA Astrophysics Data System (ADS)
Dhekne, Prakash; Pradhan, Manoj; Jade, Ravi Krishnarao
2016-04-01
Now-a-days, blasts are planned using large diameter blast holes. The loading density (kg/m) and subsequently the energy available for the breakage of the rockmass increase with the diameter. The in-hole velocity of detonation (VoD) of non-ideal explosive also boosts up with the increase in diameter till the optimum diameter is reached. The increase in the energy content and in-hole VoD cause a sizable effect on the rock fragmentation. The effect can be assessed by counting the number of oversize boulders. This paper explains as to how the technique of artificial neural network modeling was used to predict the number of oversize boulders resulting from ANFO and SME blasts with blast holes of different diameters. The results from ANFO blasts indicated that there was no significant variation in the number of oversize boulders with the diameter whereas a perceptible variation was noticed in case of SME blasts with the change in the diameter. The change in the number of oversize boulders in ANFO blasts was negligible because mean energy factor remained almost same even when the diameter of the blast holes was altered. The decrease in the number of oversize boulders in SME blasts was on account of increase in mean energy factor when the blast hole diameter was increased. The increase in the in-hole VoD due to increase in the diameter of the hole was not found to have an effect on the generation of oversize boulders as this increase was not substantial both in SME and ANFO blasts.
Technology Solutions Case Study: Advanced Boiler Load Monitoring Controls, Chicago, Illinois
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-09-01
Most of Chicago’s older multifamily housing stock is heated by centrally metered steam or hydronic systems. The cost of heat is typically absorbed into the owner’s operating cost and is then passed to tenants. Central boilers typically have long service lifetimes; the incentive for retrofit system efficiency upgrades is greater than equipment replacement for the efficiency-minded owner. System improvements as the “low-hanging fruit” are familiar, from improved pipe insulation to aftermarket controls such as outdoor temperature reset (OTR) or lead/lag controllers for sites with multiple boilers. Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoringmore » (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. In this project, the Building America team Partnership for Advanced Residential Retrofit (PARR) installed and monitored an ALM aftermarket controller, the M2G from Greffen Systems, at two Chicago area multifamily buildings with existing OTR control. Results show that energy savings depend on the degree to which boilers are oversized for their load, represented by cycling rates. Also, savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, oversized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less oversized boilers at another site showed muted savings.« less
NASA Astrophysics Data System (ADS)
Doležel, Jiří; Novák, Drahomír; Petrů, Jan
2017-09-01
Transportation routes of oversize and excessive loads are currently planned in relation to ensure the transit of a vehicle through critical points on the road. Critical points are level-intersection of roads, bridges etc. This article presents a comprehensive procedure to determine a reliability and a load-bearing capacity level of the existing bridges on highways and roads using the advanced methods of reliability analysis based on simulation techniques of Monte Carlo type in combination with nonlinear finite element method analysis. The safety index is considered as a main criterion of the reliability level of the existing construction structures and the index is described in current structural design standards, e.g. ISO and Eurocode. An example of a single-span slab bridge made of precast prestressed concrete girders of the 60 year current time and its load bearing capacity is set for the ultimate limit state and serviceability limit state. The structure’s design load capacity was estimated by the full probability nonlinear MKP analysis using a simulation technique Latin Hypercube Sampling (LHS). Load-bearing capacity values based on a fully probabilistic analysis are compared with the load-bearing capacity levels which were estimated by deterministic methods of a critical section of the most loaded girders.
Finite element analysis of unnotched charpy impact tests
DOT National Transportation Integrated Search
2008-10-01
This paper describes nonlinear finite element analysis (FEA) to examine the energy to : fracture unnotched Charpy specimens under pendulum impact loading. An oversized, : nonstandard pendulum impactor, called the Bulk Fracture Charpy Machine (BFCM), ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Eric; Withers, Chuck; McIlvaine, Janet
Low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.
Study of the influence of hole quality on composite materials
NASA Technical Reports Server (NTRS)
Pengra, J. J.
1980-01-01
The influence of hole quality on the structural behavior of composite materials was investigated. From an industry survey it was determined that the most frequent imperfections encountered during hole fabrication are chipout, delamination, and oversize conditions. These hole flaw types were generated in critical areas of static, compression, and fatigue specimens fabricated from T300/5208 graphite/epoxy system. The specimens were tested in static and cyclic pin bearing modes in addition to compression loading. Results of these tests are presented and discussed. The hole chipout defect reduced the static and cyclic endurance characteristics. Oversize holes also lowered the cyclic pin bearing endurance, but had no influence of the static pin bearing characteristics. Delamination had no insignificant influence on the static tension and cyclic pin bearing characteristics. Compression tests demonstrated a deleterious effect for chipout of delamination defects. Hole quality requirements proposed are discussed.
Ghoneim, I M; Waheed, M M; El-Bahr, S M; Alhaider, A K; Al-Eknah, M M
2013-03-01
The current study was carried out to compare some biochemical and hormonal constituents in follicular fluids from oversized follicles, preovulatory follicles, and serum in camels (Camelus dromedarius). Follicular fluids from oversized follicles (N = 10), preovulatory follicles (N = 10), and sera were harvested from 20 dromedaries. The follicular fluids and sera were subjected to biochemical and hormonal analysis. The results indicated no significant differences in the concentrations of ascorbic acid, glucose, cholesterol, acid phosphatase, and alkaline phosphatase between follicular fluid from oversized follicles and preovulatory follicles. In addition, there were no significant variations in the level of ascorbic acid, glucose, cholesterol, and acid phosphatase in the serum of animals with oversized follicles and those with preovulatory follicles. Serum alkaline phosphatase was significantly greater (P < 0.05) in camels with oversized follicles. The concentrations of estradiol-17β (E2) and insulin-like growth factor-1 (IGF-1) in the follicular fluid of oversized follicles were significantly lower (P < 0.01) than that from preovulatory follicles. There were no differences in the concentrations of progesterone, tri-iodothyronine, and thyroxin between follicular fluid from oversized follicles and that of preovulatory follicles. The concentrations of E2, progesterone, tri-iodothyronine, thyroxin, cortisol, and IGF-1 were not different in the serum of camels with oversized follicles and camels with preovulatory follicles. The current study revealed that the significant differences of biochemical and hormonal constituents between follicular fluids from oversized follicles and preovulatory follicles were restricted on E2 and IGF-1. Relaying on the aforementioned outcome we can suggest that oversized follicle phenomenon is a form of follicular atresia of anovulatory follicles. Copyright © 2013 Elsevier Inc. All rights reserved.
76 FR 71514 - Malcolm Baldrige National Quality Award Board of Overseers
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-18
... Commerce. ACTION: Notice of Open Meeting. SUMMARY: The Board of Overseers of the Malcolm Baldrige National Quality Award (Board of Overseers) will meet in open session on December 13, 2011. The purpose of this... Advisory Committee Act, 5 U.S.C. App., the Board of Overseers will meet in open session on December 13...
Expert overseer for mass spectrometer system
Filby, Evan E.; Rankin, Richard A.
1991-01-01
An expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The overseer has the capability to alert lab personnel whenever questionable readings or trends are observed and provide a background review of the problem and suggest root causes and potential solutions, or appropriate additional tests that could be performed. The overseer can change the sequence or frequency of the polling to respond to an observation in the current data.
Advanced Technology for Pyrotechnic Mixtures and Munitions
1977-07-01
or at ambient I ,/ BLENDING AND CASTING CURING REMOVING MOLD WAFER MANUFACTURING ? / I / SI ,/ iAUTOMATIC LOADING Figure 1. Plastic Bonded Starter Mix...material (fines) is recycled through the compacting rollers. asshwn The Chilsonator used at EA consisted only of the compaction rollers and the controls ...standardized process controls . Oversize material is pulverized and combined with the undersize material for s" ,regranulation in another batch. 2 ,Both the
The effect of particle size distribution on the design of urban stormwater control measures
Selbig, William R.; Fienen, Michael N.; Horwatich, Judy A.; Bannerman, Roger T.
2016-01-01
An urban pollutant loading model was used to demonstrate how incorrect assumptions on the particle size distribution (PSD) in urban runoff can alter the design characteristics of stormwater control measures (SCMs) used to remove solids in stormwater. Field-measured PSD, although highly variable, is generally coarser than the widely-accepted PSD characterized by the Nationwide Urban Runoff Program (NURP). PSDs can be predicted based on environmental surrogate data. There were no appreciable differences in predicted PSD when grouped by season. Model simulations of a wet detention pond and catch basin showed a much smaller surface area is needed to achieve the same level of solids removal using the median value of field-measured PSD as compared to NURP PSD. Therefore, SCMs that used the NURP PSD in the design process could be unnecessarily oversized. The median of measured PSDs, although more site-specific than NURP PSDs, could still misrepresent the efficiency of an SCM because it may not adequately capture the variability of individual runoff events. Future pollutant loading models may account for this variability through regression with environmental surrogates, but until then, without proper site characterization, the adoption of a single PSD to represent all runoff conditions may result in SCMs that are under- or over-sized, rendering them ineffective or unnecessarily costly.
OVERSEER: An Expert System Monitor for the Psychiatric Hospital
Bronzino, Joseph D.; Morelli, Ralph A.; Goethe, John W.
1988-01-01
In order to improve patient care, comply with regulatory guidelines and decrease potential liability, psychiatric hospitals and clinics have been searching for computer systems to monitor the management and treatment of patients. This paper describes OVERSEER: a knowledge based system that monitors the treatment of psychiatric patients in real time. Based on procedures and protocols developed in the psychiatric setting, OVERSEER monitors the clinical database and issues alerts when standard clinical practices are not followed or when laboratory results or other clinical indicators are abnormal. Written in PROLOG, OVERSEER is designed to interface directly with the hospital's database, and, thereby utilizes all available pharmacy and laboratory data. Moreover, unlike the interactive expert systems developed for the psychiatric clinic, OVERSEER does not require extensive data entry by the clinician. Consequently, the chief benefit of OVERSEER's monitoring approach is the unobtrusive manner in which it evaluates treatment and patient responses and provides information regarding patient management.
Why a Network Energy Monitoring and Control System?
1985-01-01
years to complete as they were modified to work with existing, frequently very old, buildings. The benefits derived from those systems that did work were...or groups of workstations, then certain of the occupants could be tasked to turn off their respective lighting. The advantage is the increased...units. Duty Cycle (Strategy J) This strategy takes advantage of the oversizing of the air handling unit. The air handling unit is sized for a peak load
77 FR 69795 - Malcolm Baldrige National Quality Award Board of Overseers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-21
... Quality Award Board of Overseers AGENCY: National Institute of Standards and Technology, Department of... Quality Award (Board of Overseers) will meet in open session on Wednesday, December 12, 2012. The purpose... Standards and Technology and from the Chair of the Judges' Panel of the Malcolm Baldrige National Quality...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-09-01
This brochure addresses gaps in actionable knowledge that can help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. This brochure should be used to make these decisions so systems can operate more energy efficiently; upfront capital costs will also decrease. This information can also be used to drive changes in negotiations about PPL energy demands. It should enable brokers and tenants to agree about lower PPL capacities. Owner-occupied buildings will also benefit.more » Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems.« less
Rotor-to-stator rub vibration in centrifugal compressor
NASA Technical Reports Server (NTRS)
Gao, J. J.; Qi, Q. M.
1985-01-01
One example of excessive vibration encountered during loading of a centrifugal compressor train (H type compressor with HP casing) is discussed. An investigation was made of the effects of the dynamic load on the bearing stiffness and the rotor-bearing system critical speed. The high vibration occurred at a "threshold load," but the machine didn't run smoothly due to rubs even when it had passed through the threshold load. The acquisition and discussion of the data taken in the field as well as a description of the case history which utilizes background information to identify the malfunction conditions is presented. The analysis shows that the failures, including full reverse precession rub and exact one half subharmonic vibration, were caused by the oversize bearings and displacement of the rotor center due to foundation deformation and misalignment between gear shafts, etc. The corrective actions taken to alleviate excessive vibration and the problems which remain to be solved are also presented.
Issues of using Longer Heavier Vehicles on Roads
NASA Astrophysics Data System (ADS)
Matuszkova, R.; Heczko, M.; Cepil, J.; Radimsky, M.
2018-03-01
Many logistics companies aim to save on freight costs. Recently, not only on Czech roads and on motorways, longer and heavier vehicles that exceed dimensions’ limits appeared. For these vehicles, it is necessary to apply for a special permit, which is, however, much more liberal than the permit for oversized and overweight load transport. This paper informs about checking routes of these vehicles by swept path analysis and finding locations on roads that can generate both safety risks and traffic fluency problems.
Di Dedda, Giovanni; Mirabile, Cristian
2017-01-01
We describe the implantation of an absorbable, custom-made stent of polydioxanone to treat tracheomalacia in a 5-month-old patient with extrinsic compression by a double aortic arch. The use of an absorbable, oversized stent treated the tracheal collapse caused by vascular compression, avoided removal procedures, and allowed the infant's growth. The use of an oversized stent prevented stent migration and gave minimal problems of granulation.
Plug and Process Loads Capacity and Power Requirements Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheppy, M.; Gentile-Polese, L.
2014-09-01
This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus ofmore » this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sidabras, Jason W.; Anderson, James R.; Mainali, Laxman
Experimental results have been reported on an oversize rectangular waveguide assembly operating nominally at 94 GHz. It was formed using commercially available WR28 waveguide as well as a pair of specially designed tapers with a hyperbolic-cosine shape from WR28 to WR10 waveguide [R. R. Mett et al., Rev. Sci. Instrum. 82, 074704 (2011)]. The oversize section reduces broadband insertion loss for an Electron Paramagnetic Resonance (EPR) probe placed in a 3.36 T magnet. Hyperbolic-cosine tapers minimize reflection of the main mode and the excitation of unwanted propagating waveguide modes. Oversize waveguide is distinguished from corrugated waveguide, overmoded waveguide, or quasi-opticmore » techniques by minimal coupling to higher-order modes. Only the TE{sub 10} mode of the parent WR10 waveguide is propagated. In the present work, a new oversize assembly with a gradual 90° twist was implemented. Microwave power measurements show that the twisted oversize waveguide assembly reduces the power loss in the observe and pump arms of a W-band bridge by an average of 2.35 dB and 2.41 dB, respectively, over a measured 1.25 GHz bandwidth relative to a straight length of WR10 waveguide. Network analyzer measurements confirm a decrease in insertion loss of 2.37 dB over a 4 GHz bandwidth and show minimal amplitude distortion of approximately 0.15 dB. Continuous wave EPR experiments confirm these results. The measured phase variations of the twisted oversize waveguide assembly, relative to an ideal distortionless transmission line, are reduced by a factor of two compared to a straight length of WR10 waveguide. Oversize waveguide with proper transitions is demonstrated as an effective way to increase incident power and the return signal for broadband EPR experiments. Detailed performance characteristics, including continuous wave experiment using 1 μM 2,2,6,6-tetramethylpiperidine-1-oxyl in aqueous solution, provided here serve as a benchmark for other broadband low-loss probes in millimeter-wave EPR bridges.« less
Oversize/overweight vehicle unified permitting process (UPP) : phase I.
DOT National Transportation Integrated Search
2017-08-01
Multiple jurisdictions within Minnesota process oversize/overweight (OSOW) permits for the movement of freight on state roadways, county roads, and municipal and township streets. Movement of freight has increased in recent years to help support econ...
Potential metrics for designating and monitoring oversize/overweight corridors : final report.
DOT National Transportation Integrated Search
2016-11-11
This report: - Discusses how oversize/overweight (OS/OW) corridors are currently designated in Texas. - Provides information on OS/OW corridors as detailed in the Texas Transportation Code. - Lists potential metrics (as identified by stakeholder work...
Institutional and financial analysis of weigh station performance in Georgia.
DOT National Transportation Integrated Search
2011-10-01
This report examines the State of Georgias commercial vehicle oversize and overweight enforcement : program over the past 10 years. An overview of the federal and state regulations for both oversize and overweight : vehicles is presented, which in...
Senf, B; von Sachsen, S; Neugebauer, R; Drossel, W-G; Florek, H-J; Mohr, F W; Etz, C D
2014-11-01
Stent graft fixation in the vessel affects the success of endovascular aneurysm repair. Thereby the radial forces of the stent, which are dependent on several factors, play a significant role. In the presented work, a finite element sensitivity study was performed. The radial forces are 29% lower when using the hyperelastic approach for the vessel compared with linear elastic assumptions. Without the linear elastic modeled plaque, the difference increases to 35%. Modeling plaque with linear elastic material approach results in 8% higher forces than with a hyperelastic characteristic. The significant differences resulting from the investigated simplifications of the material lead to the conclusion that it is important to apply an anisotropic nonlinear approach for the vessel. The oversizing study shows that radial forces increase by 64% (0.54 N) when raising the oversize from 10 to 22%, and no further increase in force can be observed beyond these values (vessel diameter D=12 mm). Starting from an oversize of 24%, the radial force steadily decreases. The findings of the investigation show that besides the oversizing the material properties, the ring design and the vessel characteristics have an influence on radial forces. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Web-based routing assistance tool to reduce pavement damage by overweight and oversize vehicles.
DOT National Transportation Integrated Search
2016-10-30
This report documents the results of a completed project titled Web-Based Routing Assistance Tool to Reduce Pavement Damage by Overweight and Oversize Vehicles. The tasks involved developing a Web-based GIS routing assistance tool and evaluate ...
Effect of vitreous length and trephine size disparity on post-DALK refractive status.
Javadi, Mohammad Ali; Feizi, Sepehr; Rastegarpour, Ali
2011-04-01
To evaluate the effect of vitreous length (distance between posterior lens surface and vitreoretinal interface) and donor-recipient disparity on the refraction and keratometric astigmatism after deep anterior lamellar keratoplasty (DALK). In this retrospective comparative study, 85 eyes of 83 patients with keratoconus underwent DALK using the big-bubble technique. A 0.25-mm oversize donor was used for a vitreous length of ≥ 16.0 mm, and a 0.50-mm oversize donor for a vitreous length of <16.0 mm. At least 3 months after complete suture removal, spherical equivalent refractive error (SE), keratometric astigmatism, and mean keratometry were compared between the 2 groups. Multiple regression analysis was performed in group 1 to investigate the correlation between vitreous length and SE, between vitreous length and keratometric astigmatism, and between mean keratometry and SE. Mean patient age was 26.5 ± 7.7 years, and they were followed for 22 ± 10 months postoperatively. Seventy-five eyes received a 0.25-mm oversize donor (group 1), and 10 had a donor oversized by 0.50 mm (group 2). Compared with group 1, the patients of group 2 had a significantly steeper cornea (46.83 ± 2.0 vs. 48.29 ± 1.9 diopters, respectively; P = 0.01). SE and keratometric astigmatism in group 1 did not significantly differ from those in group 2. In group 1, there was a significant association between vitreous length and SE and between mean keratometry and SE but not between vitreous length and keratometric astigmatism. In DALK, a donor oversized by 0.25 mm is advisable for elongated keratoconic eyes, whereas a 0.50-mm oversize donor is advocated for small ones.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Booten, C.; Christensen, C.; Winkler, J.
2014-11-01
This research addresses the question of what are the energy consequences for oversizing of an air conditioner in a home. Conventional wisdom holds that oversizing the AC results in significant energy penalties. However, the reason for this was shown to be due to crankcase heaters and not due to cycling performance of the AC, and is only valid for a particular set of assumptions. Adding or removing individual characteristics, such as ducts or crankcase heaters, can have measurable impacts on energy use. However, with all other home characteristics held constant, oversizing the AC generally has a small effect on coolingmore » energy use, even if the cycling performance of the unit is poor. The relevant aspects of air conditioner modeling are discussed to illustrate the effects of the cycling loss coefficient, Cd, capacity, climate, ducts and parasitic losses such as crankcase heaters. A case study of a typical 1960's vintage home demonstrates results in the context of whole building simulations using EnergyPlus.« less
Chiang, Cheng-Hsien; Yeh, Ming-Long; Chen, Wei-Ling; Kan, Chung-Dann
2016-02-01
The purpose of this study is to provide an apparatus for comparison of pullout forces for various thoracic stent grafts at varying neck angulations and oversizes. An in vitro platform capable of performing pullout tests was used on stent grafts in angulated silicone tubes designed for this study (0°, 45°, 90°, and 135° with a 32-mm inner diameter) in a temperature-controlled chamber (37 ± 2°C). Three commercial stent grafts with sizes commonly used in Taiwan (Valiant: 34, 36, 38, and 40 mm; Zenith TX2: 34, 36, 38, and 40 mm; and TAG: 34, 37, and 40 mm) were used, and each size was tested 8 times for each angulation condition. The mean dislodgement forces (DFs) at 0° angulation within 10-20% oversize were approximately 22.7, 9.6, and 9.0 N for the Valiant, Zenith TX2, and TAG devices, respectively, whereas the mean DFs decreased by 46%, 38%, and 50% to 12.3, 5.9, and 4.5 N when the angulation reached 135°. Regression analysis shows that neck angulation was a significant factor for the Valiant and Zenith TX2 devices (P < 0.0001 and P < 0.0001, respectively) but not for the TAG device (P = 0.483). In addition, oversize and interactions between variables (angulation × oversize) exhibited significant effects on the DFs for all devices (P < 0.0001). We successfully built up an apparatus for comparison of pullout forces for various thoracic stent grafts at varying neck angulations and oversizes. With the empirical comparative data of different brand stent grafts under various conditions shown and compared, our findings suggest that aortic neck angulation has a negative correlation with stent-graft fixation. To have better stent-graft fixation and seal in the aortic arch for thoracic endovascular aortic repair, a longer landing zone with cautiously selected oversize is a more suitable selection. Copyright © 2016 Elsevier Inc. All rights reserved.
DOT National Transportation Integrated Search
2017-09-01
MnDOT uses two online systems implemented in the 1990s to issue and manage permits for oversize/overweight (OS/OW) freight and motor carrier credentials: - RouteBuilder, an OS/OW permitting system with a routing component. - Motor Carrier Information...
25 CFR 170.933 - Can tribes regulate oversize or overweight vehicles?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true Can tribes regulate oversize or overweight vehicles? 170... RESERVATION ROADS PROGRAM Miscellaneous Provisions Tribal Transportation Departments § 170.933 Can tribes... accordance with applicable Federal law. BIA may, with the consent of the affected tribe, establish a...
25 CFR 170.933 - Can tribes regulate oversize or overweight vehicles?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Can tribes regulate oversize or overweight vehicles? 170... RESERVATION ROADS PROGRAM Miscellaneous Provisions Tribal Transportation Departments § 170.933 Can tribes... accordance with applicable Federal law. BIA may, with the consent of the affected tribe, establish a...
25 CFR 170.933 - Can tribes regulate oversize or overweight vehicles?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false Can tribes regulate oversize or overweight vehicles? 170... RESERVATION ROADS PROGRAM Miscellaneous Provisions Tribal Transportation Departments § 170.933 Can tribes... accordance with applicable Federal law. BIA may, with the consent of the affected tribe, establish a...
25 CFR 170.933 - Can tribes regulate oversize or overweight vehicles?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false Can tribes regulate oversize or overweight vehicles? 170... RESERVATION ROADS PROGRAM Miscellaneous Provisions Tribal Transportation Departments § 170.933 Can tribes... accordance with applicable Federal law. BIA may, with the consent of the affected tribe, establish a...
25 CFR 170.933 - Can tribes regulate oversize or overweight vehicles?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false Can tribes regulate oversize or overweight vehicles? 170... RESERVATION ROADS PROGRAM Miscellaneous Provisions Tribal Transportation Departments § 170.933 Can tribes... accordance with applicable Federal law. BIA may, with the consent of the affected tribe, establish a...
3. PERSPECTIVE VIEW OF OVERSEERS COTTAGE AT 110 CORINTH ROAD. ...
3. PERSPECTIVE VIEW OF OVERSEERS COTTAGE AT 110 CORINTH ROAD. NOTE ORIGINAL WOOD SIDING, PORCH POSTS, AND STEPS. ORIGINALLY THIS HOUSE SAT ON BRICK PIERS WITH WOOD LATTICE BETWEEN. THE FOUNDATION HAS NOW BEEN INFILLED WITH BRICK. - 110 Corinth Road (House), 110 Corinth Road, Hogansville, Troup County, GA
Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Withers, Jr., Charles R.
2016-12-01
In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split onmore » seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-01-01
In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split onmore » seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.« less
NASA Technical Reports Server (NTRS)
Meyer, Caitlin E.; Pensinger, Stuart; Pickering, Karen D.; Barta, Daniel; Shull, Sarah A.; Vega, Letticia M.; Christenson, Dylan; Jackson, W. Andrew
2015-01-01
Membrane aerated bioreactors (MABR) are attached-growth biological systems used for simultaneous nitrification and denitrification to reclaim water from waste. This design is an innovative approach to common terrestrial wastewater treatments for nitrogen and carbon removal and implementing a biologically-based water treatment system for long-duration human exploration is an attractive, low energy alternative to physiochemical processes. Two obstacles to implementing such a system are (1) the "start-up" duration from inoculation to steady-state operations and (2) the amount of surface area needed for the biological activity to occur. The Advanced Water Recovery Systems (AWRS) team at JSC explored these two issues through two tests; a rapid inoculation study and a wastewater loading study. Results from these tests demonstrate that the duration from inoculation to steady state can be reduced to under two weeks, and that despite low ammonium removal rates, the MABRs are oversized.
Publications - Beikman, H.M., 1980 | Alaska Division of Geological &
main content USGS Beikman, H.M., 1980 Publication Details Title: Geologic map of Alaska Authors Warehouse Bibliographic Reference Beikman, H.M., 1980, Geologic map of Alaska: U.S. Geological Survey, 1 USGS website Maps & Other Oversized Sheets Maps & Other Oversized Sheets Sheet 1 Geologic Map
Implementation of a real-time statistical process control system in hardwood sawmills
Timothy M. Young; Brian H. Bond; Jan Wiedenbeck
2007-01-01
Variation in sawmill processes reduces the financial benefit of converting fiber from a log into lumber. Lumber is intentionally oversized during manufacture to allow for sawing variation, shrinkage from drying, and final surfacing. This oversizing of lumber due to sawing variation requires higher operating targets and leads to suboptimal fiber recovery. For more than...
A novel stochastic modeling method to simulate cooling loads in residential districts
An, Jingjing; Yan, Da; Hong, Tianzhen; ...
2017-09-04
District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3)more » a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.« less
A novel stochastic modeling method to simulate cooling loads in residential districts
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, Jingjing; Yan, Da; Hong, Tianzhen
District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3)more » a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.« less
ERIC Educational Resources Information Center
Pereira, Licinio Chainho; And Others
A study examined the current needs of middle management in the textile and clothing industry in Portugal. Focus was on Level 3--foremen, overseers, and team leaders. Eight of 400 enterprises responded to the first questionnaire; 370 of 1,000 responded to the revised questionnaire. The following data were collected: number of employees according to…
78 FR 36431 - Safety Zone; Inbound Transit of M/V TEAL, Savannah River; Savannah, GA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-18
... of four oversized ship to shore (STS) cranes. The moving safety zone will transition to a temporary... these oversized cranes and offloading operations. Entry into this zone is prohibited unless specifically... and offloading operations of four STS cranes to CB8. Under 5 U.S.C. 553(d)(3), for the same reasons as...
Publications - RI 97-15A | Alaska Division of Geological & Geophysical
content DGGS RI 97-15A Publication Details Title: Geologic map of the Tanana B-1 Quadrangle, central ., and Weber, F.R., 1997, Geologic map of the Tanana B-1 Quadrangle, central Alaska: Alaska Division of ; Other Oversized Sheets Maps & Other Oversized Sheets Sheet 1 Geologic map of the Tanana B-1
Huang, Ting; Ouyang, Chen; Hou, Chao; Wu, Qianni; Hu, Yunwei
2016-06-01
To evaluate the efficacy of the same-size host and donor trephine on reducing myopic refractive errors for patients with keratoconus when deep anterior lamellar keratoplasty (DALK) was used. Randomized controlled clinical trial. One hundred eighteen eyes of 118 patients with keratoconus were enrolled. Using stratified blocked randomization, eligible eyes were allocated into the same-size trephine group or oversize trephine group. Postoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), spherical equivalent (SE), topography data, and eye axial length were compared at each year for 5 years. The same-size trephine group had comparable UCVA to the oversize trephine group through 5 years after surgery. But the former had better BSCVA than the latter after 3 years of follow-up. At 5 years, mean BSCVA was 0.17 ± 0.10 logMAR in the same-size trephine group vs 0.25 ± 0.13 logMAR in the oversize trephine group (P = .03). The same-size trephine group had lower topographic power than the oversize trephine group after 3 years of follow-up. At 5 years, mean topographic power was 45.30 ± 2.28 diopters (D) in the same-size trephine group vs 46.75 ± 2.60 D in the oversize trephine group (P = .006). Eye axial lengths at 5 years were longer than those preoperatively as well as at 1 year follow-up after surgery in both groups. The same-size host and donor trephine could reduce late-stage myopic refractive errors for the patients with keratoconus after DALK. The mechanism may be late-stage axial length increase with time. Copyright © 2016 Elsevier Inc. All rights reserved.
Abdel-Aal, Ahmed Kamel; Massoud, Moustafa Omar; Elantably, Dina Mahmoud
2017-01-01
PURPOSE Occlusion time (OT) is an important factor in the treatment of pulmonary arteriovenous malformations (PAVMs) since it can lead to serious complications. The purpose of our study is to calculate the OT of Amplatzer vascular plug (AVP, St Jude Medical), and correlate it to the type of the device used (AVP or AVP 2) and the percent of device oversizing. Technical success rates and complications were also recorded. METHODS We retrospectively studied a total of 19 patients with 47 PAVMs who received percutaneous transcatheter embolization therapy using either AVP or AVP 2. We recorded the location, type, feeding artery diameter, AVP device used, and OT of each PAVM. We correlated the percent of device oversizing and the type of AVP with the OT. We also studied the rate of persistence of PAVM for both devices. RESULTS Forty-six (98%) of the PAVMs were simple. Device diameters ranged from 4.0–16.0 mm with device oversizing ranging between 14% and 120%. There was a statistically significant difference in the OT of AVP and AVP 2 (3 min 54 s vs. 5 min 30 s, P = 0.030). There was a weak positive correlation between OT and device oversizing for AVP (r=0.246, P = 0.324) and AVP 2 (r=0.261, P = 0.240). No major complications were identified. Immediate technical success rate was 100%. CONCLUSION The use of AVP 2, and increase in device oversizing were not associated with reduction in the OT of PAVMs. There was no reported difference in safety between the two devices, and no major complications were noted. PMID:27856403
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arena, Lois
The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculationmore » methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.« less
Safety studies on vacuum insulated liquid helium cryostats
NASA Astrophysics Data System (ADS)
Weber, C.; Henriques, A.; Zoller, C.; Grohmann, S.
2017-12-01
The loss of insulating vacuum is often considered as a reasonable foreseeable accident for the dimensioning of cryogenic safety relief devices (SRD). The cryogenic safety test facility PICARD was designed at KIT to investigate such events. In the course of first experiments, discharge instabilities of the spring loaded safety relief valve (SRV) occurred, the so-called chattering and pumping effects. These instabilities reduce the relief flow capacity, which leads to impermissible over-pressures in the system. The analysis of the process dynamics showed first indications for a smaller heat flux than the commonly assumed 4W/cm2. This results in an oversized discharge area for the reduced relief flow rate, which corresponds to the lower heat flux. This paper presents further experimental investigations on the venting of the insulating vacuum with atmospheric air under variation of the set pressure (p set) of the SRV. Based on dynamic process analysis, the results are discussed with focus on effective heat fluxes and operating characteristics of the spring-loaded SRV.
Lead-acid battery construction
NASA Technical Reports Server (NTRS)
Rowlette, John J. (Inventor)
1988-01-01
The power characteristics of a lead-acid battery are improved by incorporating a dispersion of 1 to 10% by weight of a thermodynamically stable conductivity additive, such as conductive tin oxide coated glass fibers (34) of filamentary glass wool (42) in the positive active layer (32) carried on the grid (30) of the positive plate (16). The avoiding of positive plate reversal to prevent reduction of the tin oxide is accomplished by (a) employing an oversized positive plate and pre-charging it; (b) by pre-discharging the negative plate; and/or (c) by placing a circuit breaker (26) in combination with the plates (16, 18) and terminals (22, 24) to remove the load when the voltage of the positive plate falls below a pre-selected level.
Transportation of Large Wind Components: A Permitting and Regulatory Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levine, Aaron; Cook, Jeff
This report summarizes permitting and regulatory issues associated with transporting wind turbine blades, towers, and nacelles as well as large transformers (wind components). These wind components are commonly categorized as oversized and overweight (OSOW) and require specific permit approvals from state and local jurisdictions. The report was developed based on a Quadrennial Energy Review (QER) recommendation on logistical requirements for the transportation of 'oversized or high-consequence energy materials, equipment, and components.'
Publications - PDF 98-37A v. 1.1 | Alaska Division of Geological &
main content DGGS PDF 98-37A v. 1.1 Publication Details Title: Geologic map of the Tanana A-1 and A-2 ., 1998, Geologic map of the Tanana A-1 and A-2 quadrangles, central Alaska: Alaska Division of Geological & Other Oversized Sheets Maps & Other Oversized Sheets Sheet 1 Preliminary geologic map of the
Dezube, Rebecca; Arnaoutakis, George J; Reed, Robert M; Bolukbas, Servet; Shah, Ashish S; Orens, Jonathan B; Brower, Roy G; Eberlein, Michael
2013-03-01
Mechanical ventilation tidal volumes are usually set according to an estimate of patient size in millilitres (ml) per kilogram (kg) body weight. We describe the relationship between donor-recipient lung-size mismatch and postoperative mechanical ventilation tidal volumes according to recipient- and donor-predicted body weights in a cohort of bilateral lung transplant patients. A most-undersized (10 patients with lowest predicted total lung capacity [pTLC] ratio = pTLC-donor/pTLC-recipient), a most-oversized (10 patients with highest pTLC ratio) and best-matched subset (10 patients with predicted total lung capacity ratio closest to 1.0) were selected within a cohort of 70 patients. All tidal volumes during mechanical ventilation in the first 96 h after bilateral lung transplantation were recorded. Tidal volumes were expressed in ml and ml/kg-recipient-predicted body weights and ml/kg-donor-predicted body weights. Postoperative absolute tidal volumes (in ml) were comparable between subsets of patients with undersized, matched and oversized allografts (552 ± 103 vs 581 ± 107 vs 582 ± 104 ml), and tidal volumes in ml/kg-recipient-predicted body weights were also similar (8.8 ± 1.4 vs 9.3 ± 1.1 vs 9.8 ± 2.1). However, tidal volumes in ml/kg-donor-predicted body weights revealed significant differences between undersized, matched, and oversized subsets (11.4 ± 3.1 vs 9.4 ± 1.2 vs 8.1 ± 2.1, respectively; P < 0.05). Two patients developed primary graft dysfunction grade 3, both in the undersized subset. Four patients in the undersized group underwent tracheotomy (vs none in matched and one in oversized subset). During mechanical ventilation after bilateral lung transplantation, undersized allografts received relatively higher tidal volumes compared with oversized allografts when the tidal volumes were related to donor-predicted body weights.
Improvement in conformability of the latest generation of thoracic stent grafts.
Canaud, Ludovic; Cathala, Philipe; Joyeux, Frédéric; Branchereau, Pascal; Marty-Ané, Charles; Alric, Pierre
2013-04-01
Poor aortic arch apposition increases the risk of technical failure after thoracic endovascular repair. The aim of this study was to assess the conformability of the latest generation of thoracic stent grafts in relation to the degree of device oversizing and aortic arch angulation. A benchtop pulsatile flow model was designed to test stent graft anchorage in a 2-cm-long proximal landing zone at varying landing zone angles (from 140° down to 70°) and stent graft oversizing (12%-28%). The experiments were performed using 10 human thoracic cadaveric aortas and four stent grafts: C-TAG, Zenith TX2 Pro-Form, Valiant Captivia, and Relay. Device-wall apposition was measured as a function of landing zone angulation and oversizing during static and dynamic (60 pulses/min, 300/150 mm Hg) tests. The Valiant stent graft remained apposed to the aortic wall at each increment of neck angulation and device oversizing. Lack of apposition of the proximal anchorage segment was observed with the C-TAG above 120° landing zone angulation (1-2 mm) and with the Relay above 110° landing zone angulation (1-4 mm). Lack of "body" apposition (1-4 mm) was first observed with the Zenith Pro-Form stent graft above 110° angulation (P = .001). When the device was not apposed to the aortic wall, an increase in stent graft oversizing significantly (P = .01) decreased device-wall apposition. The requirement for close conformability has influenced the design of next-generation devices. Manufacturers have modified devices and/or their deployment system to specifically address this problem. When compared with the results of our previous experimental test, this study demonstrates that these alterations have resulted in a marked improvement in the performance of commercially available stent graft systems. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Double arch mirror study. Part 1: Preliminary engineering report
NASA Technical Reports Server (NTRS)
Vukobratovich, D.; Hillman, D.
1983-01-01
In the proposed design, the NASA AMES 20-in double arch mirror is supported by three clamp and flexure assemblies. The mirror clamp consists of a T-shaped Invar-36 member that goes into a similarly shaped socket in the back of the mirror. The mirror socket is made oversize and contacts the clamp only along the conical surface. The clamp is preloaded by a spring washer and pulls the mirror into contact with the flexure. The clamp is then inserted into the mirror socket through a cutout, is rotated 90 deg, and is then pinned in place. Loading conditions considered in socket design are discussed as well as stress in the socket and clamp. Flexure geometry and stress are examined as well as the effects of flexure error and of mirror cell error.
1999-10-06
KENNEDY SPACE CENTER, FLA. -- NASA's Super Guppy airplane, with the International Space Station's (ISS) S1 truss aboard, rolls to a stop at KSC's Shuttle Landing Facility. Manufactured by the Boeing Co. in Huntington Beach, Calif., this component of the ISS is the first starboard (right-side) truss segment, whose main job is providing structural support for the orbiting research facility's radiator panels that cool the Space Station's complex power system. The S1 truss segment also will house communications systems, external experiment positions and other subsystems. Primarily constructed of aluminum, the truss segment is 45 feet long, 15 feet wide and 6 feet tall. When fully outfitted, it will weigh 31,137 pounds. The truss is slated for flight in 2001. The Super Guppy, with its 25-foot diameter fuselage designed to handle oversized loads, is well prepared to transport the truss and other ISS segments. Loading the Guppy is easy because of the unique "fold-away" nose of the aircraft that opens 110 degrees for cargo loading. A system of rails in the cargo compartment, used with either Guppy pallets or fixtures designed for specific cargo, makes cargo loading simple and efficient. Rollers mounted in the rails allow pallets or fixtures to be moved by an electric winch mounted beneath the cargo floor. Automatic hydraulic lock pins in each rail secure the pallet for flight. The truss is to be transferred to the Operations and Checkout Building
1999-10-06
KENNEDY SPACE CENTER, FLA. -- NASA's Super Guppy airplane, with the International Space Station's (ISS) S1 truss aboard, arrives at KSC's Shuttle Landing Facility from Marshall Space Flight Center. Manufactured by the Boeing Co. in Huntington Beach, Calif., this component of the ISS is the first starboard (right-side) truss segment, whose main job is providing structural support for the orbiting research facility's radiator panels that cool the Space Station's complex power system. The S1 truss segment also will house communications systems, external experiment positions and other subsystems. Primarily constructed of aluminum, the truss segment is 45 feet long, 15 feet wide and 6 feet tall. When fully outfitted, it will weigh 31,137 pounds. The truss is slated for flight in 2001. The Super Guppy, with its 25-foot diameter fuselage designed to handle oversized loads, is well prepared to transport the truss and other ISS segments. Loading the Guppy is easy because of the unique "fold-away" nose of the aircraft that opens 110 degrees for cargo loading. A system of rails in the cargo compartment, used with either Guppy pallets or fixtures designed for specific cargo, makes cargo loading simple and efficient. Rollers mounted in the rails allow pallets or fixtures to be moved by an electric winch mounted beneath the cargo floor. Automatic hydraulic lock pins in each rail secure the pallet for flight. The truss is to be moved to the Operations and Checkout Building
1999-10-07
KENNEDY SPACE CENTER, FLA. -- At KSC's Shuttle Landing Facility, NASA's Super Guppy opens to reveal its cargo, the International Space Station's (ISS) S1 truss. Manufactured by the Boeing Co. in Huntington Beach, Calif., this component of the ISS is the first starboard (right-side) truss segment, whose main job is providing structural support for the orbiting research facility's radiator panels that cool the Space Station's complex power system. The S1 truss segment also will house communications systems, external experiment positions and other subsystems. Primarily constructed of aluminum, the truss segment is 45 feet long, 15 feet wide and 6 feet tall. When fully outfitted, it will weigh 31,137 pounds. The truss is slated for flight in 2001. The Super Guppy, with its 25-foot diameter fuselage designed to handle oversized loads, is well prepared to transport the truss and other ISS segments. Loading the Guppy is easy because of the unique "fold-away" nose of the aircraft that opens 110 degrees for cargo loading. A system of rails in the cargo compartment, used with either Guppy pallets or fixtures designed for specific cargo, makes cargo loading simple and efficient. Rollers mounted in the rails allow pallets or fixtures to be moved by an electric winch mounted beneath the cargo floor. Automatic hydraulic lock pins in each rail secure the pallet for flight. The truss is to be transferred to the Operations and Checkout Building
1999-10-07
KENNEDY SPACE CENTER, FLA. -- At the Shuttle Landing Facility, workers attach cranes to the S1 truss, a segment of the International Space Station, to lift the truss to a payload transporter for its transfer to the Operations and Checkout Building. Manufactured by the Boeing Co. in Huntington Beach, Calif., this component of the ISS is the first starboard (right-side) truss segment, whose main job is providing structural support for the orbiting research facility's radiator panels that cool the Space Station's complex power system. The S1 truss segment also will house communications systems, external experiment positions and other subsystems. Primarily constructed of aluminum, the truss segment is 45 feet long, 15 feet wide and 6 feet tall. When fully outfitted, it will weigh 31,137 pounds. The truss is slated for flight in 2001. The truss arrived at KSC aboard NASA's Super Guppy, with a 25-foot diameter fuselage designed to handle oversized loads. Loading the Guppy is easy because of the unique "fold-away" nose of the aircraft that opens 110 degrees for cargo loading. A system of rails in the cargo compartment, used with either Guppy pallets or fixtures designed for specific cargo, makes cargo loading simple and efficient. Rollers mounted in the rails allow pallets or fixtures to be moved by an electric winch mounted beneath the cargo floor. Automatic hydraulic lock pins in each rail secure the pallet for flight
1999-10-07
KENNEDY SPACE CENTER, FLA. -- At the Shuttle Landing Facility, the newly arrived S1 truss, a segment of the International Space Station (ISS), is offloaded from NASA's Super Guppy aircraft. Manufactured by the Boeing Co. in Huntington Beach, Calif., this component of the ISS is the first starboard (right-side) truss segment, whose main job is providing structural support for the orbiting research facility's radiator panels that cool the Space Station's complex power system. The S1 truss segment also will house communications systems, external experiment positions and other subsystems. Primarily constructed of aluminum, the truss segment is 45 feet long, 15 feet wide and 6 feet tall. When fully outfitted, it will weigh 31,137 pounds. The truss is slated for flight in 2001. The Super Guppy, with its 25-foot diameter fuselage designed to handle oversized loads, is well prepared to transport the truss and other ISS segments. Loading the Guppy is easy because of the unique "fold-away" nose of the aircraft that opens 110 degrees for cargo loading. A system of rails in the cargo compartment, used with either Guppy pallets or fixtures designed for specific cargo, makes cargo loading simple and efficient. Rollers mounted in the rails allow pallets or fixtures to be moved by an electric winch mounted beneath the cargo floor. Automatic hydraulic lock pins in each rail secure the pallet for flight. The truss is being transferred to the Operations and Checkout Building
Rajwani, Adil; Shirazi, Masoumeh G; Disney, Patrick J S; Wong, Dennis T L; Teo, Karen S L; Delacroix, Sinny; Chokka, Ramesh G; Young, Glenn D; Worthley, Stephen G
2015-12-01
Predictors of residual leak following percutaneous LAA closure were evaluated. Left atrial appendage (LAA) closure aims to exclude this structure from the circulation, typically using a circular occluder. A noncircular orifice is frequently encountered however, and fibrous remodeling of the LAA in atrial fibrillation may restrict orifice deformation. Noncircularity may thus be implicated in the occurrence of residual leak despite an appropriately oversized device. Pre-procedural multislice computerized tomography was used to quantify LAA orifice eccentricity and irregularity. Univariate predictors of residual leak were identified with respect to the orifice, device, and relevant clinical variables, with the nature of any correlations then further evaluated. Eccentricity and irregularity indexes of the orifice in 31 individuals were correlated with residual leak even where the device was appropriately oversized. An eccentricity index of 0.15 predicted a residual leak with 85% sensitivity and 59% specificity. An irregularity index of 0.05 predicted a significant residual leak ≥3 mm with 100% sensitivity and 86% specificity. Orifice size, device size, degree of device oversize, left atrial volume, and pulmonary artery pressure were not predictors of residual leak. Eccentricity and irregularity of the LAA orifice are implicated in residual leak after percutaneous closure even where there is appropriate device over-size. Irregularity index in particular is a novel predictor of residual leak, supporting a closer consideration of orifice morphology before closure. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Commissioning of inline ECE system within waveguide based ECRH transmission systems on ASDEX upgrade
NASA Astrophysics Data System (ADS)
Bongers, W. A.; Kasparek, W.; Doelman, N.; van den Braber, R.; van den Brand, H.; Meo, F.; de Baar, M. R.; Amerongen, F. J.; Donné, A. J. H.; Elzendoorn, B. S. Q.; Erckmann, V.; Goede, A. P. H.; Giannone, L.; Grünwald, G.; Hollman, F.; Kaas, G.; Krijger, B.; Michel, G.; Lubyako, L.; Monaco, F.; Noke, F.; Petelin, M.; Plaum, B.; Purps, F.; ten Pierik, J. G. W.; Schüller, C.; Slob, J. W.; Stober, J. K.; Schütz, H.; Wagner, D.; Westerhof, E.; Ronden, D. M. S.
2012-09-01
A CW capable inline electron cyclotron emission (ECE) separation system for feedback control, featuring oversized corrugated waveguides, is commissioned on ASDEX upgrade (AUG). The system is based on a combination of a polarization independent, non-resonant, Mach-Zehnder diplexer equipped with dielectric plate beam splitters [2, 3] employed as corrugated oversized waveguide filter, and a resonant Fast Directional Switch, FADIS [4, 5, 6, 7] as ECE/ECCD separation system. This paper presents an overview of the system, the low power characterisation tests and first high power commissioning on AUG.
1999-10-07
KENNEDY SPACE CENTER, FLA. -- Escort vehicles prepare to leave the Shuttle Landing Facility with the S1 truss (at right) on its trek to the Operations and Checkout Building. Manufactured by the Boeing Co. in Huntington Beach, Calif., this component of the ISS is the first starboard (right-side) truss segment, whose main job is providing structural support for the orbiting research facility's radiator panels that cool the Space Station's complex power system. The S1 truss segment also will house communications systems, external experiment positions and other subsystems. Primarily constructed of aluminum, the truss segment is 45 feet long, 15 feet wide and 6 feet tall. When fully outfitted, it will weigh 31,137 pounds. The truss is slated for flight in 2001. The truss arrived at KSC aboard NASA's Super Guppy, seen in the background. The aircraft is uniquely built with a 25-foot diameter fuselage designed to handle oversized loads and a "fold-away" nose that opens 110 degrees for cargo loading. A system of rails in the cargo compartment, used with either Guppy pallets or fixtures designed for specific cargo, makes cargo loading simple and efficient. Rollers mounted in the rails allow pallets or fixtures to be moved by an electric winch mounted beneath the cargo floor. Automatic hydraulic lock pins in each rail secure the pallet for flight
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munk, Jeffrey D; Odukomaiya, Adewale O; Gehl, Anthony C
2014-01-01
With the recent advancements in the application of variable-speed (VS) compressors to residential HVAC systems, opportunities are now available to size heat pumps (HPs) to more effectively meet heating and cooling loads in many of the climate zones in the US with limited use of inefficient resistance heat. This is in contrast to sizing guidance for traditional single-speed HPs that limits the ability to oversize with regard to cooling loads, because of risks of poor dehumidification during the cooling season and increased cycling losses. VS-drive HPs can often run at 30-40% of their rated cooling capacity to reduce cycling losses,more » and can adjust fan speed to provide better indoor humidity control. Detailed air-side performance data was collected on two VS-drive heat pumps installed in a single unoccupied research house in Knoxville, TN, a mixed-humid climate. One system provided space conditioning for the upstairs, while the other unit provided space conditioning for the downstairs. Occupancy was simulated by operating the lights, shower, appliances, other plug loads, etc. to simulate the sensible and latent loads imposed on the building space by internal electric loads and human occupants according to the Building America Research Benchmark (2008). The seasonal efficiency and energy use of the units are calculated. Annual energy use is compared to that of the single speed minimum efficiency HPs tested in the same house previously. Sizing of the units relative to the measured building load and manual J design load calculations is examined. The impact of the unit sizing with regards to indoor comfort is also evaluated.« less
Amirouche, Farid; Solitro, Giovanni F; Walia, Amit; Gonzalez, Mark; Bobko, Aimee
2017-08-01
Management of segmental rim defects and bone mineral density (BMD) loss in the elderly prior to total hip replacement is unclear within classification systems for acetabular bone loss. In this study, our objectives were (1) to understand how a reduction in BMD in the elderly affects the oversizing of a press-fit cup for primary fixation and (2) to evaluate whether the location of the segmental defect affected cup fixation. A finite element (FE) model was used to simulate and evaluate cup insertion and fixation in the context of segmental rim defects. We focused on the distribution of patients over age 70 and used BMD (estimated from CT) as a proxy for aging's implications on THR and used probabilistic FE analysis to understand how BMD loss affects oversizing of a press-fit cup. A cup oversized by 1.10 ± 0.28 mm provides sufficient fixation and lower stresses at the cup-bone interface for elderly patients. Defects in the anterior column and posterior column both required the same mean insertion force for cup seating of 84% (taken as an average of 2 anterior column and 2 posterior column defects) compared to the control configuration, which was 5% greater than the insertion force for a superior rim defect and 12% greater than the insertion force for an inferior rim defect. A defect along the superior or inferior rim had a minimal effect on cup fixation, while a defect in the columns created cup instability and increased stress at the defect location.
Schindera, Sebastian T; Nelson, Rendon C; Toth, Thomas L; Nguyen, Giao T; Toncheva, Greta I; DeLong, David M; Yoshizumi, Terry T
2008-02-01
The purpose of this study was to evaluate in a phantom study the effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation. One or two 4-cm-thick circumferential layers of fat-equivalent material were added to the abdomen of an anthropomorphic phantom to simulate patients of three sizes: small (cross-sectional dimensions, 18 x 22 cm), average size (26 x 30 cm), and oversize (34 x 38 cm). Imaging was performed with a 64-MDCT scanner with combined z-axis and xy-axis tube current modulation according to two protocols: protocol A had a noise index of 12.5 H, and protocol B, 15.0 H. Radiation doses to three abdominal organs and the skin were assessed. Image noise also was measured. Despite increasing patient size, the image noise measured was similar for protocol A (range, 11.7-12.2 H) and protocol B (range, 13.9-14.8 H) (p > 0.05). With the two protocols, in comparison with the dose of the small patient, the abdominal organ doses of the average-sized patient and the oversized patient increased 161.5-190.6%and 426.9-528.1%, respectively (p < 0.001). The skin dose increased as much as 268.6% for the average-sized patient and 816.3% for the oversized patient compared with the small patient (p < 0.001). Oversized patients undergoing abdominal MDCT with tube current modulation receive significantly higher doses than do small patients. The noise index needs to be adjusted to the body habitus to ensure dose efficiency.
NASA Technical Reports Server (NTRS)
McCoy, Allen H.
1998-01-01
Helicopter external air transportation plays an important role in today's world. For both military and civilian helicopters, external sling load operations offer an efficient and expedient method of handling heavy, oversized cargo. With the ability to reach areas otherwise inaccessible by ground transportation, helicopter external load operations are conducted in industries such as logging, construction, and fire fighting, as well as in support of military tactical transport missions. Historically, helicopter and load combinations have been qualified through flight testing, requiring considerable time and cost. With advancements in simulation and flight test techniques there is potential to substantially reduce costs and increase the safety of helicopter sling load certification. Validated simulation tools make possible accurate prediction of operational flight characteristics before initial flight tests. Real time analysis of test data improves the safety and efficiency of the testing programs. To advance these concepts, the U.S. Army and NASA, in cooperation with the Israeli Air Force and Technion, under a Memorandum of Agreement, seek to develop and validate a numerical model of the UH-60 with sling load and demonstrate a method of near real time flight test analysis. This thesis presents results from flight tests of a U.S. Army Black Hawk helicopter with various external loads. Tests were conducted as the U.S. first phase of this MOA task. The primary load was a container express box (CONEX) which contained a compact instrumentation package. The flights covered the airspeed range from hover to 70 knots. Primary maneuvers were pitch and roll frequency sweeps, steps, and doublets. Results of the test determined the effect of the suspended load on both the aircraft's handling qualities and its control system's stability margins. Included were calculations of the stability characteristics of the load's pendular motion. Utilizing CIFER(R) software, a method for near-real time system identification was also demonstrated during the flight test program.
LSPM J1314+1320: An Oversized Magnetic Star with Constraints on the Radio Emission Mechanism
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDonald, James; Mullan, D. J.
LSPM J1314+1320 (=NLTT 33370) is a binary star system consisting of two nearly identical pre-main-sequence stars of spectral type M7. The system is remarkable among ultracool dwarfs for being the most luminous radio emitter over the widest frequency range. Masses and luminosities are at first sight consistent with the system being coeval at age ∼80 Myr according to standard (nonmagnetic) evolutionary models. However, these models predict an average effective temperature of ∼2950 K, which is 180 K hotter than the empirical value. Thus, the empirical radii are oversized relative to the standard models by ≈13%. We demonstrate that magnetic stellarmore » models can quantitatively account for the oversizing. As a check on our models, we note that the radio emission limits the surface magnetic field strengths: the limits depend on identifying the radio emission mechanism. We find that the field strengths required by our magnetic models are too strong to be consistent with gyrosynchrotron emission but are consistent with electron cyclotron maser emission.« less
Spectrum fatigue testing of T-shaped tension clips
NASA Astrophysics Data System (ADS)
Palmberg, Bjoern; Wallstenius, Bengt
1992-12-01
An investigation of strain distributions during static loading and crack propagation and fatigue lives under spectrum loading of T-shaped tension clips was carried out. Three slightly different, with respect to geometry, T shaped tension clips made of aluminum alloy 7010-T73651 were studied. The type 1 and 4 test specimens were different only with respect to the web thickness of the clamping end. The type 1 and 2 test specimens were different with repect to milled flat circular countersink around the holes in the type 2 specimens and with respect to the radius between the web and foot. The spectrum fatigue loading consisted of a load sequence representative for the wing root, lower side, of a fighter aircraft. Tests were made at two different load levels for each specimen type. The strain measurements show that the countersink in the type 2 specimens increases the stresses in the fatigue critical region. This is also manifested in the spectrum fatigue life results, where type 2 specimens show the shortest fatigue lives. The strain measurements show that the torque used for the bolts in joining two test specimens or one test specimen and a dummy has a rather large impact on the strain in the fatigue region. The strains decrease with increasing torque. The spectrum fatigue loading resulted in approximately an equal number of flights to obtain a 10.0 mm crack for specimens of type 1 and 4. This suggests that the type 1 configuration is superior since the web thickness is smaller for this type as compared to the type 4 specimens. In other words, the type 4 specimens have an unnecessary oversize of the clamping end web thickness.
1999-10-07
KENNEDY SPACE CENTER, FLA. -- At the Shuttle Landing Facility, the S1 truss, a segment of the International Space Station, is moved away from the Super Guppy that brought it to KSC from Marshall Space Flight Center. Manufactured by the Boeing Co. in Huntington Beach, Calif., this component of the ISS is the first starboard (right-side) truss segment, whose main job is providing structural support for the orbiting research facility's radiator panels that cool the Space Station's complex power system. The S1 truss segment also will house communications systems, external experiment positions and other subsystems. Primarily constructed of aluminum, the truss segment is 45 feet long, 15 feet wide and 6 feet tall. When fully outfitted, it will weigh 31,137 pounds. The truss is slated for flight in 2001. The Super Guppy, with its 25-foot diameter fuselage designed to handle oversized loads, is well prepared to transport the truss and other ISS segments. Loading the Guppy is easy because of the unique "fold-away" nose of the aircraft that opens 110 degrees for cargo loading. A system of rails in the cargo compartment, used with either Guppy pallets or fixtures designed for specific cargo, makes cargo loading simple and efficient. Rollers mounted in the rails allow pallets or fixtures to be moved by an electric winch mounted beneath the cargo floor. Automatic hydraulic lock pins in each rail secure the pallet for flight. The truss is being transferred to the Operations and Checkout Building
STS-112 S1 Truss Payload arrives at KSC
NASA Technical Reports Server (NTRS)
1999-01-01
KENNEDY SPACE CENTER, FLA. -- NASA's Super Guppy airplane, with the International Space Station's (ISS) S1 truss aboard, rolls to a stop at KSC's Shuttle Landing Facility. Manufactured by the Boeing Co. in Huntington Beach, Calif., this component of the I SS is the first starboard (right-side) truss segment, whose main job is providing structural support for the orbiting research facility's radiator panels that cool the Space Station's complex power system. The S1 truss segment also will house communicatio ns systems, external experiment positions and other subsystems. Primarily constructed of aluminum, the truss segment is 45 feet long, 15 feet wide and 6 feet tall. When fully outfitted, it will weigh 31,137 pounds. The truss is slated for flight in 2001. The Super Guppy, with its 25-foot diameter fuselage designed to handle oversized loads, is well prepared to transport the truss and other ISS segments. Loading the Guppy is easy because of the unique 'fold-away' nose of the aircraft that opens 110 degrees for cargo loading. A system of rails in the cargo compartment, used with either Guppy pallets or fixtures designed for specific cargo, makes cargo loading simple and efficient. Rollers mounted in the rails allow pallets or fixtures to be moved by an elec tric winch mounted beneath the cargo floor. Automatic hydraulic lock pins in each rail secure the pallet for flight. The truss is to be transferred to the Operations and Checkout Building
Surplus from and storage of electricity generated by intermittent sources
NASA Astrophysics Data System (ADS)
Wagner, Friedrich
2016-12-01
Data from the German electricity system for the years 2010, 2012, 2013, and 2015 are used and scaled up to a 100% supply by intermittent renewable energy sources (iRES). In the average, 330GW wind and PV power are required to meet this 100% target. A back-up system is necessary with the power of 89% of peak load. Surplus electricity accrues at high power levels. Curtailing surplus power to a large extent is found to be uneconomic. Demand-side management will suffer from the strong day-to-day variation of available surplus energy. A day storage is ineffective because of the day-night correlation of surplus power during winter. A seasonal storage loses its character when transformation losses are considered because it can contribute only after periods with excessive surplus production. The option of an oversized iRES system to feed the storage is also not effective because, in this case, energy can be taken directly from the large iRES supply, making storage superfluous. The capacities to be installed stress the difficulty to base heat supply and mobility also on iRES generated electricity in the future. As the German energy transition replaces one CO2-free electricity supply system by another one, no major reduction in CO2 emission can be expected till 2022, when the last nuclear reactor will be switched off. By 2022, an extremely oversized power supply system has to be created, which can be expected to continue running down spot-market electricity prices. The continuation of the economic response -to replace expensive gas fuel by cheap lignite- causes an overall increase in CO2 emission. The German GHG emission targets for 2020 and beyond are therefore in jeopardy.
Gregorio de Souza, Jonas; Robinson, Mark; Corteletti, Rafael; Cárdenas, Macarena Lucia; Wolf, Sidnei; Iriarte, José; Mayle, Francis; DeBlasis, Paulo
2016-01-01
A long held view about the occupation of southern proto-Jê pit house villages of the southern Brazilian highlands is that these sites represent cycles of long-term abandonment and reoccupation. However, this assumption is based on an insufficient number of radiocarbon dates for individual pit houses. To address this problem, we conducted a programme of comprehensive AMS radiocarbon dating and Bayesian modelling at the deeply stratified oversized pit House 1, Baggio I site (Cal. A.D. 1395-1650), Campo Belo do Sul, Santa Catarina state, Brazil. The stratigraphy of House 1 revealed an unparalleled sequence of twelve well preserved floors evidencing a major change in occupation dynamics including five completely burnt collapsed roofs. The results of the radiocarbon dating allowed us to understand for the first time the occupation dynamics of an oversized pit house in the southern Brazilian highlands. The Bayesian model demonstrates that House 1 was occupied for over two centuries with no evidence of major periods of abandonment, calling into question previous models of long-term abandonment. In addition, the House 1 sequence allowed us to tie transformations in ceramic style and lithic technology to an absolute chronology. Finally, we can provide new evidence that the emergence of oversized domestic structures is a relatively recent phenomenon among the southern proto-Jê. As monumental pit houses start to be built, small pit houses continue to be inhabited, evidencing emerging disparities in domestic architecture after AD 1000. Our research shows the importance of programmes of intensive dating of individual structures to understand occupation dynamics and site permanence, and challenges long held assumptions that the southern Brazilian highlands were home to marginal cultures in the context of lowland South America.
Gregorio de Souza, Jonas; Robinson, Mark; Corteletti, Rafael; Cárdenas, Macarena Lucia; Wolf, Sidnei; Iriarte, José; Mayle, Francis; DeBlasis, Paulo
2016-01-01
A long held view about the occupation of southern proto-Jê pit house villages of the southern Brazilian highlands is that these sites represent cycles of long-term abandonment and reoccupation. However, this assumption is based on an insufficient number of radiocarbon dates for individual pit houses. To address this problem, we conducted a programme of comprehensive AMS radiocarbon dating and Bayesian modelling at the deeply stratified oversized pit House 1, Baggio I site (Cal. A.D. 1395–1650), Campo Belo do Sul, Santa Catarina state, Brazil. The stratigraphy of House 1 revealed an unparalleled sequence of twelve well preserved floors evidencing a major change in occupation dynamics including five completely burnt collapsed roofs. The results of the radiocarbon dating allowed us to understand for the first time the occupation dynamics of an oversized pit house in the southern Brazilian highlands. The Bayesian model demonstrates that House 1 was occupied for over two centuries with no evidence of major periods of abandonment, calling into question previous models of long-term abandonment. In addition, the House 1 sequence allowed us to tie transformations in ceramic style and lithic technology to an absolute chronology. Finally, we can provide new evidence that the emergence of oversized domestic structures is a relatively recent phenomenon among the southern proto-Jê. As monumental pit houses start to be built, small pit houses continue to be inhabited, evidencing emerging disparities in domestic architecture after AD 1000. Our research shows the importance of programmes of intensive dating of individual structures to understand occupation dynamics and site permanence, and challenges long held assumptions that the southern Brazilian highlands were home to marginal cultures in the context of lowland South America. PMID:27384341
Relationship between aneurysm occlusion and flow diverting device oversizing in a rabbit model.
Hodis, Simona; Ding, Yong-Hong; Dai, Daying; Lingineni, Ravi; Mut, Fernando; Cebral, Juan; Kallmes, David; Kadirvel, Ramanathan
2016-01-01
Implanted, actual flow diverter pore density is thought to be strongly influenced by proper matching between the device size and parent artery diameter. The objective of this study was to characterize the correlation between device sizing, metal coverage, and the resultant occlusion of aneurysms following flow diverter treatment in a rabbit model. Rabbit saccular aneurysms were treated with flow diverters (iso-sized to proximal parent artery, 0.5 mm oversized, or 1.0 mm oversized, respectively, n=6 for each group). Eight weeks after implantation, the angiographic degree of aneurysm occlusion was graded (complete, near-complete, or incomplete). The ostium of the explanted aneurysm covered with the flow diverter struts was photographed. Based on gross anatomic findings, the metal coverage and pore density at the ostium of the aneurysm were calculated and correlated with the degree of aneurysm occlusion. Angiographic results showed there were no statistically significant differences in aneurysm geometry and occlusion among groups. The mean parent artery diameter to flow diverter diameter ratio was higher in the 1.0 mm oversized group than in the other groups. Neither the percentage metal coverage nor the pore density showed statistically significant differences among groups. Aneurysm occlusion was inversely correlated with the ostium diameter, irrespective of the size of the device implanted. Device sizing alone does not predict resultant pore density or metal coverage following flow diverter implantation in the rabbit aneurysm model. Aneurysm occlusion was not impacted by either metal coverage or pore density, but was inversely correlated with the diameter of the ostium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Winter, Werner; Karl, Matthias
2014-10-01
Acetabular cup endoprostheses are frequently placed in pelvic bone, employing the mechanical principle of press fit. While a sufficiently stable bone-implant connection is desirable, deformation of the cup and fracture of the pelvis should be avoided. The goal of this work is to demonstrate the importance of the elastic properties of bone on the amount of press fit achievable in a specific situation. On the basis of previous work describing the relation between relative bone mineral density and relative elastic modulus for cortical and trabecular bone, mechanical equations were used for analyzing the press-fit loading situation of an acetabular cup. Additionally, a two-dimensional finite element model was used for visualizing the stress and strain situation in the host bone occurring as a consequence of implant insertion, as well as the effect of moment loads acting on the acetabular cup. Given the fact that oversizing the implant for a specific recipient site is the only clinical means of optimizing press fit, knowledge of the elastic properties of the host bone before implant selection would be beneficial. Such information could, for instance, be derived from intraoperative compressive testing of the host bone.
NASA Astrophysics Data System (ADS)
Li, Shifeng; Duan, Zhaoyun; Huang, Hua; Liu, Zhenbang; He, Hu; Wang, Fei; Wang, Zhanliang; Gong, Yubin
2018-04-01
In this paper, an extended interaction oversized coaxial relativistic klystron amplifier (EIOC-RKA) with Gigawatt-level output at Ka band is proposed. We introduce the oversized coaxial and multi-gap resonant cavities to increase the power capacity and investigate a non-uniform extended interaction output cavity to improve the electronic efficiency of the EIOC-RKA. We develop a high order mode gap in the input and output cavities to easily design and fabricate the input and output couplers. Meanwhile, we design the EIOC-RKA by using the particle-in-cell simulation. In the simulations, we use an electron beam with a current of 6 kA and a voltage of 525 kV, which is focused by a low focusing magnetic flux intensity of 0.5 T. The simulation results demonstrate that the saturated output power is 1.17 GW, the electronic efficiency is 37.1%, and the saturated gain is 57 dB at 30 GHz. The self-oscillation is suppressed by adopting the absorbing materials. The proposed EIOC-RKA has plenty of advantages such as large power capacity, high electronic efficiency, low focusing magnetic, high gain, and simple structure.
Effects of oversized solutes on radiation-induced segregation in austenitic stainless steels
NASA Astrophysics Data System (ADS)
Hackett, M. J.; Busby, J. T.; Miller, M. K.; Was, G. S.
2009-06-01
Zirconium or hafnium additions to austenitic stainless steels caused a reduction in grain boundary Cr depletion after proton irradiations for up to 3 dpa at 400 °C and 1 dpa at 500 °C. The predictions of a radiation-induced segregation (RIS) model were also consistent with experiments in showing greater effectiveness of Zr relative to Hf due to a larger binding energy. However, the experiments showed that the effectiveness of the solute additions disappeared above 3 dpa at 400 °C and above 1 dpa at 500 °C. The loss of solute effectiveness with increasing dose is attributed to a reduction in the amount of oversized solute from the matrix due to growth of carbide precipitates. Atom probe tomography measurements indicated a reduction in amount of oversized solute in solution as a function of irradiation dose. The observations were supported by diffusion analysis suggesting that significant solute diffusion by the vacancy flux to precipitate surfaces occurs on the time scales of proton irradiations. With a decrease in available solute in solution, improved agreement between the predictions of the RIS model and measurements were consistent with the solute-vacancy trapping process, as the mechanism for enhanced recombination and suppression of RIS.
Configuration affects parallel stent grafting results.
Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L
2018-05-01
A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31.25% of retrograde stents having any complication. Parallel stent grafting offers an off-the-shelf option to treat a variety of aortic diseases. There is an increased risk of parallel stent and overall EVAR compromise with <10% main body oversizing. Thirty-day mortality is increased when more than one parallel stent is placed. Antegrade configurations are preferred to any retrograde configuration, with optimal oversizing >20%. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hackett, Micah Jeremiah
The objective of this thesis is to quantify the effect of oversized solutes on radiation-induced segregation in austenitic stainless steels and to determine the mechanism of this effect. Zr or Hf additions to austenitic stainless steels demonstrated a reduction in radiation-induced segregation of Cr and Ni at the grain boundary after proton irradiation at 400°C and 500°C to low doses, but the solute effect disappeared at higher doses. Rate theory modeling of RIS was extended to incorporate a solute-vacancy trapping mechanism to predict the effect of solutes on RIS. The model showed that RIS is most sensitive to the solute-vacancy binding energy. First principles calculations were used to determine a binding energy of 1.08 eV for Zr and 0.71 eV for Hf. Model and experiment agreed in showing suppression of Cr depletion at doses of 3 dpa at 400°C and 1 dpa at 500°C, and experimental results were consistent with the model in showing greater effectiveness of Zr relative to Hf due to a larger binding energy. The dislocation loop microstructure was measured at 400°C, 3 and 7 dpa, and a significant decrease in loop density and total loop line length in the oversized solute alloys relative to the reference alloys. The loop microstructure results were consistent with RIS results by confirming enhanced recombination of point defects by solute-vacancy trapping. Increases in RIS with dose indicated a loss of solute effectiveness, which was consistent with an observed increase in loop line length from 3 to 7 dpa. The loss of solute effectiveness at high dose is attributed to a loss of oversized solute from the matrix due to coarsening of carbide precipitates. X-ray diffraction identified a microstructure with ZrC or HfC precipitates prior to irradiation. Precipitate coarsening was identified as the most likely mechanism for the loss of solute effectiveness on RIS by the following: (1) diffusion analysis suggested significant solute diffusion by the vacancy flux to precipitate surfaces on the time scales of proton irradiations, and (2) atom probe measurements confirmed the loss of oversized solute in solution as a function of irradiation dose. RIS measurements and subsequent analyses were consistent with the solute-vacancy trapping process as the mechanism for enhanced recombination and suppression of RIS.
Expandable pallet for space station interface attachments
NASA Technical Reports Server (NTRS)
Wesselski, Clarence J. (Inventor)
1988-01-01
Described is a foldable expandable pallet for Space Station interface attachments with a basic square configuration. Each pallet consists of a series of struts joined together by node point fittings to make a rigid structure. The struts have hinge fittings which are spring loaded to permit collapse of the module for stowage transport to a Space Station in the payload bay of the Space Shuttle, and development on orbit. Dimensions of the pallet are selected to provide convenient, closely spaced attachment points between the node points of the relatively widely spaced trusses of a Space Station platform. A pallet is attached to a strut at four points: one close fitting hole, two oversize holes, and a slot to allow for thermal expansion/contraction and for manufacturing tolerances. Applications of the pallet include its use in rotary or angular joints; servicing of splints; with gridded plates; as instrument mounting bases; and as a roadbed for a Mobile Service Center (MSC).
Mask patterning process using the negative tone chemically amplified resist TOK OEBR-CAN024
NASA Astrophysics Data System (ADS)
Irmscher, Mathias; Beyer, Dirk; Butschke, Joerg; Hudek, Peter; Koepernik, Corinna; Plumhoff, Jason; Rausa, Emmanuel; Sato, Mitsuru; Voehringer, Peter
2004-08-01
Optimized process parameters using the TOK OEBR-CAN024 resist for high chrome load patterning have been determined. A tight linearity tolerance for opaque and clear features, independent on the local pattern density, was the goal of our process integration work. For this purpose we evaluated a new correction method taking into account electron scattering and process influences. The method is based on matching of measured pattern geometry by iterative back-simulation using multiple Gauss and/or exponential functions. The obtained control function acts as input for the proximity correction software PROXECCO. Approaches with different pattern oversize and two Cr thicknesses were accomplished and the results have been reported. Isolated opaque and clear lines could be realized in a very tight linearity range. The increasing line width of small dense lines, induced by the etching process, could be corrected only partially.
Residential Variable-Capacity Heat Pumps Sized to Heating Loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munk, Jeffrey D.; Jackson, Roderick K.; Odukomaiya, Adewale
2014-01-01
Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in themore » cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.« less
Zhao, Yang; Yin, Henghui; Chen, Yitian; Wang, Mian; Zheng, Liang; Li, Zilun; Chang, Guangqi
2018-01-01
Distal stent graft-induced new entry (SINE) can occur after thoracic endovascular aortic repair (TEVAR) of type B aortic dissection. This study investigated the mechanism of distal SINE and its prevention using a restrictive bare stent (RBS) technique. From January 2013 to December 2014, 68 consecutive type B aortic dissection patients received endovascular repair at our center. The RBS technique was used with distal oversizing (between the diameter of the thoracic stent graft and the descending aorta true lumen diameter at the level of the intended distal edge of the thoracic stent graft) >20%. Twenty-three patients received TEVAR with a single thoracic stent graft (TEVAR group, n = 23); the rest received TEVAR combined with the RBS technique (TEVAR + RBS group, n = 45). Four distal SINEs occurred in the TEVAR group. Distal oversizing (69.7% ± 35.5% vs 31.2% ± 24.5%; P = .005) and expansion mismatch ratio (132.2% ± 16.9% vs 106.5% ± 11.6%; P < .05) were significantly higher in the SINE patients. Compared with standard TEVAR, TEVAR + RBS was associated with significantly lower distal oversizing (TEVAR vs TEVAR + RBS group, 59.8% ± 24.7% vs 16.7% ± 7.6%; P < .05), lower expansion mismatch ratio (113.8% ± 14.6% vs 103.8% ± 11.7%; P = .012), and lower distal SINE rate (4/23 [17.4%] vs 0/45 [0%]; P = .011). Compared with the TEVAR group, the false lumen was reduced significantly at the level of the RBS distal edge (P = .029). Excessive distal oversizing and distal expansion mismatch ratio may contribute to the occurrence of distal SINE. The RBS technique reduced the incidence of distal SINE. Based on our midterm and long-term observations, implantation of an RBS may improve aortic remodeling. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Experimental and numerical investigation of a RC wall loaded by snow-like avalanche pressure signal
NASA Astrophysics Data System (ADS)
Ousset, Isabelle; Bertrand, David; Brun, Michaël; Limam, Ali; Naaïm, Mohamed
2013-04-01
Nowadays, civil engineering structures exposed to snow avalanches are mostly designed considering static loadings involving large safety factors. These latters highlight the lack of knowledge about the effects of the loading generated by a snow flow, and generally lead to oversize the civil structure. Indeed, the transient nature of the loading signal and also the composition of the snow flow can generate dynamic phenomena which cannot be taken into account considering only static loadings. The case of the avalanche of the Taconnaz (France), which occurred in 1999 and where important parts of the defense structure were destroyed, showed that static design approaches can lead to underestimate the potential effect of the snow flow. Thus, in order to give some new insights about this issue, the effect of the temporal variations of the snow loading on the mechanical behavior of an idealized defense structure is investigated. Therefore, a reinforced concrete (RC) wall with a L-like shape has been considered which is supposed to represent a part of the defense structure situated in Taconnaz. Static pushover tests, carried out in laboratory conditions on 1/6 scale physical model of the RC structure, allowed obtaining the capacity of the tested structure (Berthet-Rambaud et al. (2007)). Finite Element (FE) models have been developed and calibrated from the previous experimental data. The FE approach allows simulating the dynamic mechanical response of the structure. The effect of the transient nature of the loading of the avalanche has been explored applying out-of-plan dynamic loadings on the RC wall. In order to be as close as possible of a "field" snow avalanche, the imposed time evolution of the loading has been generated from in situ measurements recorded at the French experimental site "le col du Lautaret" (Thibert et al. (2008)). The RC mechanical behaviour has been described by four nonlinear constitutive laws. The four behaviour laws are compared and analyzed for specific loading situations. Next, the influences of typical parameters characterizing the avalanche loading signal are proposed. In particular, a special focused is presented on the effect of the loading rate. Finally, the vulnerability of the RC wall is studied in a reliability framework. Damage index are proposed and the probability of failure of the RC wall is derived. These relations might be useful for risk analysis.
Are insertion torque and early osseointegration proportional? A histologic evaluation.
Campos, Felipe E B; Jimbo, Ryo; Bonfante, Estevam A; Barbosa, Darceny Z; Oliveira, Maiolino T F; Janal, Malvin N; Coelho, Paulo G
2015-11-01
The objective of this histologic study was to determine the effect of three drilling protocols (oversized, intermediate, and undersized) on biologic responses to a single implant type at early healing periods (2 weeks in vivo) in a beagle dog model. Ten beagle dogs were acquired and subjected to surgeries in the tibia 2 weeks before euthanasia. During surgery, each dog received three Unitite implants, 4 mm in diameter by 10 mm in length, in bone sites drilled to 3.5, 3.75, and 4.0 mm in final diameter. The insertion torque was recorded during surgery, and bone-to-implant contact (BIC), and bone area fraction occupied (BAFO) measured from the histology. Each outcome measure was compared between treatment conditions with the Wilcoxon signed-rank test. Bonferroni-corrected statistical significance was set to 95%. Insertion torque increased as an inverse function of drilling diameter, as indicated by significant differences in torque levels between each pair of conditions (P = 0.005). BIC and BAFO levels were highest and statistically similar in the recommended and undersized conditions and significantly reduced in the oversized condition (P < 0.01). Reduced drilling dimensions resulted in increased insertion torque (primary stability). While BIC and BAFO were maximized when drilling the recommended diameter hole, only the oversized hole resulted in evidence of statistically reduced integration. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Palo Alto Research Center - Smart Embedded Network of Sensors with an Optical Readout
Raghavan, Ajay; Sahu, Saroj; Bringans, Ross; Johnson, Noble; Kiesel, Peter; Saha, Bhaskar
2018-05-18
PARC is developing new fiber optic sensors that would be embedded into batteries to monitor and measure key internal parameters during charge and discharge cycles. Two significant problems with today's best batteries are their lack of internal monitoring capabilities and their design oversizing. The lack of monitoring interferes with the ability to identify and manage performance or safety issues as they arise, which are presently managed by very conservative design oversizing and protection approaches that result in cost inefficiencies. PARC's design combines low-cost, embedded optical battery sensors and smart algorithms to overcome challenges faced by today's best battery management systems. These advanced fiber optic sensing technologies have the potential to dramatically improve the safety, performance, and life-time of energy storage systems.
Nambiar, Bindu; Cornell Sookdeo, Cathleen; Berthelette, Patricia; Jackson, Robert; Piraino, Susan; Burnham, Brenda; Nass, Shelley; Souza, David; O'Riordan, Catherine R; Vincent, Karen A; Cheng, Seng H; Armentano, Donna; Kyostio-Moore, Sirkka
2017-02-01
Several ongoing clinical studies are evaluating recombinant adeno-associated virus (rAAV) vectors as gene delivery vehicles for a variety of diseases. However, the production of vectors with genomes >4.7 kb is challenging, with vector preparations frequently containing truncated genomes. To determine whether the generation of oversized rAAVs can be improved using a producer cell-line (PCL) process, HeLaS3-cell lines harboring either a 5.1 or 5.4 kb rAAV vector genome encoding codon-optimized cDNA for human B-domain deleted Factor VIII (FVIII) were isolated. High-producing "masterwells" (MWs), defined as producing >50,000 vg/cell, were identified for each oversized vector. These MWs provided stable vector production for >20 passages. The quality and potency of the AAVrh8R/FVIII-5.1 and AAVrh8R/FVIII-5.4 vectors generated by the PCL method were then compared to those prepared via transient transfection (TXN). Southern and dot blot analyses demonstrated that both production methods resulted in packaging of heterogeneously sized genomes. However, the PCL-derived rAAV vector preparations contained some genomes >4.7 kb, whereas the majority of genomes generated by the TXN method were ≤4.7 kb. The PCL process reduced packaging of non-vector DNA for both the AAVrh8R/FVIII-5.1 and the AAVrh8R/FVIII-5.4 kb vector preparations. Furthermore, more DNA-containing viral particles were obtained for the AAVrh8R/FVIII-5.1 vector. In a mouse model of hemophilia A, animals administered a PCL-derived rAAV vector exhibited twofold higher plasma FVIII activity and increased levels of vector genomes in the liver than mice treated with vector produced via TXN did. Hence, the quality of oversized vectors prepared using the PCL method is greater than that of vectors generated using the TXN process, and importantly this improvement translates to enhanced performance in vivo.
Farno, E; Coventry, K; Slatter, P; Eshtiaghi, N
2018-06-15
Sludge pumps in wastewater treatment plants are often oversized due to uncertainty in calculation of pressure drop. This issue costs millions of dollars for industry to purchase and operate the oversized pumps. Besides costs, higher electricity consumption is associated with extra CO 2 emission which creates huge environmental impacts. Calculation of pressure drop via current pipe flow theory requires model estimation of flow curve data which depends on regression analysis and also varies with natural variation of rheological data. This study investigates impact of variation of rheological data and regression analysis on variation of pressure drop calculated via current pipe flow theories. Results compare the variation of calculated pressure drop between different models and regression methods and suggest on the suitability of each method. Copyright © 2018 Elsevier Ltd. All rights reserved.
36 CFR 1237.16 - How do agencies store audiovisual records?
Code of Federal Regulations, 2014 CFR
2014-07-01
....g., store poster series separately from other kinds of agency publications, or photographic series... § 1237.3); (e) Store posters and similar graphic works in oversize formats, in map cases, hanging files...
36 CFR 1237.16 - How do agencies store audiovisual records?
Code of Federal Regulations, 2012 CFR
2012-07-01
....g., store poster series separately from other kinds of agency publications, or photographic series... § 1237.3); (e) Store posters and similar graphic works in oversize formats, in map cases, hanging files...
Accommodating oversize/overweight vehicles at roundabouts.
DOT National Transportation Integrated Search
2013-01-01
Safety and traffic operational benefits of roundabouts for the typical vehicle fleet (automobiles and small trucks) have been well documented. Although roundabouts have been in widespread use in other countries for many years, their general use in th...
1. GENERAL VIEW OF COMPLEX, SHOWING FACTORY BUILDING IN LEFT ...
1. GENERAL VIEW OF COMPLEX, SHOWING FACTORY BUILDING IN LEFT FOREGROUND, GRINDING PLATFORM AT REAR OF FACTORY, AND STABLE AREA AND OVERSEER'S HOUSE TO RIGHT - Caneel Bay Plantation, General Views, Cruz Bay, St. John, VI
36 CFR § 1237.16 - How do agencies store audiovisual records?
Code of Federal Regulations, 2013 CFR
2013-07-01
... textual series (e.g., store poster series separately from other kinds of agency publications, or... reference, see § 1237.3); (e) Store posters and similar graphic works in oversize formats, in map cases...
Metal drilling with portable hand drills
NASA Technical Reports Server (NTRS)
Edmiston, W. B.; Harrison, H. W.; Morris, H. E.
1970-01-01
Study of metal drilling solves problems of excessive burring, oversized holes, and out-of-round holes. Recommendations deal with using the proper chemical coolants, applying the coolants effectively, employing cutting oils, and dissipating the heat caused by drilling.
Analysis of INDOT current hydraulic policies.
DOT National Transportation Integrated Search
2011-01-01
Hydraulic design often tends to be on a conservative side for safety reasons. Hydraulic structures are : typically oversized with the goal being reduced future maintenance costs, and to reduce the risk of : property owner complaints. This approach le...
75 FR 56994 - Malcolm Baldrige National Quality Award Board of Overseers
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
... Commerce. ACTION: Notice of Open Meeting. SUMMARY: Pursuant to the Federal Advisory Committee Act, 5 U.S.C... prominent in the fields of quality, innovation, and performance management and appointed by the Secretary of...
75 FR 18788 - Malcolm Baldrige National Quality Award Panel of Judges and Board of Overseers
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-13
... the fields of quality, innovation, and performance management and appointed by the Secretary of..., Baldrige Program Changes in 2010 and 2011, and Implementation of the Strategic Plan Actions. DATES: The...
Analysis of INDOT current hydraulic policies : [spreadsheet].
DOT National Transportation Integrated Search
2011-01-01
Hydraulic design often tends to be on a conservative side for safety reasons. Hydraulic structures are typically oversized with the goal being reduced future maintenance costs, and to reduce the risk of property owner complaints. This approach leads ...
Re-plumbing in a Mediterranean sponge.
Mendola, D; van den Boogaart, J G M; van Leeuwen, J L; Wijffels, R H
2007-12-22
Observations are reported for Dysidea avara sponges where once functioning oscula (outlets) are converted through internal re-plumbing into functioning oversized ostia (OSO; inlets). Flow tank studies employed high-speed photography and particle tracking of laser-illuminated 0.5-6.0 microm diameter glass beads to trace particles streaming into OSO. A fluorescein dye/glass bead uptake experiment showed that an oversized ostium was connected through internal structures to the lone osculum. Beginning 30 s after uptake and continuing over a 20 min period, dye streamed from the osculum, but no beads emerged. Scanning electron microscopy revealed that beads were deposited only on the inhalant side of particle filtering choanocyte chambers and not on the exhalant side, suggesting that internal re-plumbing had occurred. Functioning OSO were also found on freshly collected specimens in the field, making it highly unlikely that formation of OSO was only an artefact of sponges being held in a laboratory tank.
The recreation of a unique shrimp's mechanically induced cavitation bubble
NASA Astrophysics Data System (ADS)
Miller, Ryan; Dougherty, Christopher; Eliasson, Veronica; Khanolkar, Gauri
2014-11-01
The Alpheus heterochaelis, appropriately nicknamed the ``pistol shrimp,'' possesses an oversized claw that creates a cavitation bubble upon rapid closure. The implosion of this bubble results in a shock wave that can stun or even kill the shrimp's prey (Versluis et al., 2000). Additionally, the implosion is so violent that sonoluminescence may occur. This light implies extreme temperatures, which have been recorded to reach as high as 10,000 K (Roach, 2001). By developing an analogous mechanism to the oversized claw, the goal of this experiment is to verify that cavitation can be produced similar to that of the pistol shrimp in nature as well as to analyze the resulting shock wave and sonoluminescence. High-speed schlieren imaging was used to observe the shock dynamics. Furthermore, results on cavitation collapse and light emission will be presented. USC Provost Undergraduate Research Fellowship/Rose Hills Undergraduate Research Fellowship.
NASA Astrophysics Data System (ADS)
Pawel, Stefaniak; Jacek, Wodecki; Jakubiak, Janusz; Zimroz, Radoslaw
2017-12-01
Production chain (PCh) in underground copper ore mine consists of several subprocesses. From our perspective implementation of so called ZEPA approach (Zero Entry Production Area) might be very interesting [16]. In practice, it leads to automation/robotization of subprocesses in production area. In this paper was investigated a specific part of PCh i.e. a place when cyclic transport by LHDs is replaced with continuous transport by conveying system. Such place is called dumping point. The objective of dumping points with screen is primary classification of the material (into coarse and fine material) and breaking oversized rocks with hydraulic hammer. Current challenges for the underground mining include e.g. safety improvement as well as production optimization related to bottlenecks, stoppages and operational efficiency of the machines. As a first step, remote control of the hydraulic hammer has been introduced, which not only transferred the operator to safe workplace, but also allowed for more comfortable work environment and control over multiple technical objects by a single person. Today literature analysis shows that current mining industry around the world is oriented to automation and robotization of mining processes and reveals technological readiness for 4th industrial revolution. The paper is focused on preliminary analysis of possibilities for the use of the robotic system to rock-breaking process. Prototype test rig has been proposed and experimental works have been carried out. Automatic algorithms for detection of oversized rocks, crushing them as well as sweeping and loosening of material have been formulated. Obviously many simplifications have been assumed. Some near future works have been proposed.
Brunswick County road orders, 1732-1746.
DOT National Transportation Integrated Search
1988-01-01
The establishment and maintenance of public roads were among the most important functions of the county court during the colonial period in Virginia. Each road was opened and maintained by an overseer (or surveyor) of the highways, who was appointed ...
Augusta County road orders, 1745-1769.
DOT National Transportation Integrated Search
1998-01-01
The establishment and maintenance of public roads were among the most important functions of the county court during the colonial period in Virginia. Each road was opened and maintained by an overseer (or surveyor) of the highways, who was appointed ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-23
... issues of manufacturing companies, service companies, small businesses, health care providers, and... Panel Update and Ethics Review, Applicants and Eligibility, New Business/ Public Comment. The agenda may...
Feasibility of developing a pilot car training and certification program in Alabama.
DOT National Transportation Integrated Search
2010-09-01
The State of Alabama does not currently require certification for the pilot car drivers who escort : oversize/overweight vehicles. The Alabama Department of Transportation contracted with The University : Transportation Center for Alabama (UTCA) to i...
Feasibility of developing a pilot car training and certification program in Alabama
DOT National Transportation Integrated Search
2010-09-01
The State of Alabama does not currently require certification for the pilot car drivers who escort : oversize/overweight vehicles. The Alabama Department of Transportation contracted with The University : Transportation Center for Alabama (UTCA) to i...
Analysis of INDOT current hydraulic policies : [technical summary].
DOT National Transportation Integrated Search
2011-01-01
Hydraulic design often tends to be on a conservative side for safety reasons. Hydraulic structures are typically oversized with the goal being reduced future maintenance costs, and to reduce the risk of property owner complaints. This approach leads ...
Orange County road orders, 1734-1749.
DOT National Transportation Integrated Search
1984-01-01
The establishment and maintenance of public roads were among the most important functions of the county court during the colonial period in Virginia. Each road was opened and maintained by an overseer (or surveyor) of the highways, who was appointed ...
Lunenburg County road orders, 1746-1764.
DOT National Transportation Integrated Search
1993-01-01
The establishment and maintenance of public roads were among the most important functions of the county court during the colonial period in Virginia. Each road was opened and maintained by an overseer (or surveyor) of the highways, who was appointed ...
Orange County road orders, 1750-1800.
DOT National Transportation Integrated Search
1989-01-01
The establishment and maintenance of public roads were among the most important functions of the county court during the colonial period in Virginia. Each road was opened and maintained by an overseer (or surveyor) of the highways, who was appointed ...
Spotsylvania County road orders, 1722-1734.
DOT National Transportation Integrated Search
1985-01-01
The establishment and maintenance of public roads were among the most important functions of the county court during the colonial period in Virginia. Each road was opened and maintained by an overseer (or surveyor) of the highways, who was appointed ...
Oversize/overweight permitting practices review : phase II.
DOT National Transportation Integrated Search
2013-02-01
This study explores a more detailed analysis of the permitting process in the Mid-Atlantic Region and : delves into operational practice, and theory and history of the practice among states. The states : practices examined in greater detail include C...
Publications - AR 1981 | Alaska Division of Geological & Geophysical
Sheets Maps & Other Oversized Sheets Plate 1 Significant mineral deposits and prospects in Alaska (6.8 M) Plate 2 Major active claim blocks and development projects in Alaska, scale 1:42,240 (13.0 M
Three pledget technique for closure of muscular ventricular septal defects.
Sharma, Rajesh; Katewa, Ashish
2012-07-01
We propose a modification of the simple, horizontal mattress, pledgetted suture technique for closing the small muscular ventricular septal defect (VSD) by interposing an oversized third pledget on the left ventricular (LV) aspect of the defect.
77 FR 25686 - Malcolm Baldrige National Quality Award Board of Overseers and Panel of Judges
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-01
..., Baldrige Enterprise Update, Judges Panel Update, Baldrige Fellows Program Discussion, and Strategic Planning. DATES: The meeting will convene on Thursday, June 14, 2012, at 8:30 a.m. Eastern time and adjourn...
Super Heavy-Duty Door Hardware.
ERIC Educational Resources Information Center
Fickes, Michael
2000-01-01
Discusses the new generation of durable school-door hardware and innovations that can resist everyday abuse. Concluding comments address cross-corridor door innovations that can help doorways more easily accommodate the passage of oversized items, and classroom door locking systems. (GR)
Accommodating oversize/overweight vehicles at roundabouts : [technical summary].
DOT National Transportation Integrated Search
2013-02-01
Safety and traffic operational benefits of roundabouts for the typical vehicle fleet (automobiles and small trucks) have been well documented. Although roundabouts have been in widespread use in other countries for many years, their general use in th...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Cibro Petroleum Products has built a 30,000 bbl/day hydroskimming refinery that went on stream in fall 1978 and is to produce naphtha and No. 6 and 2 fuel oils. The nine major assemblies were fabricated, prepiped, prewired, insulated, instrumented, and tested by Berry Corp. in Corpus Christi, Tex., and barged via the intracoastal waterway and the Hudson River to Albany. A nominal 30,000 bbl/day topping plant, a naphtha stabilizer, two new 10 in. loading arms at the dock, major revisions of the tank farm piping system, and upgrading of the existing boiler house and electrical facilities comprised the project. Themore » primary distillation column and heaters are oversized, and with added pumps, could increase capacity to over 40,000 bbl/day. Conventional cone roof tanks with internal floaters were chosen over floating roof tanks because of the severe winters. The plant has a hydrogen sulfide caustic scrubber to clean up the refinery gas prior to combustion; there are facilities for treating the wastewater, prior to discharge to the Albany County sewer district, and treating slop oil. An API separator and dissolved air flotation units provide for oil separation.« less
Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo
2018-05-15
Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.
Estimating design discharges for drainage structures in western Kansas.
DOT National Transportation Integrated Search
2013-06-01
KDOT engineers have expressed concern that the hydrologic methods in the current KDOT Design Manual (Volume I, : Part C, 2011) may lead to over-sizing of drainage structures in Western Kansas. Some new structures designed by the current : methods are...
Culpeper County road orders, 1763-1764 : final report.
DOT National Transportation Integrated Search
1994-01-01
The establishment and maintenance of public roads were among the most important functions of the county court during the colonial period in Virginia. Each road was opened and maintained by an overseer (or surveyor) of the highways, who was appointed ...
Aligning oversize/overweight permit fees with agency costs : critical issues.
DOT National Transportation Integrated Search
2013-08-01
This project provides an elementary analysis of issues and a proposed framework for the state to evaluate cost recovery options : due to OSOW operations. The authors provide a review of current permitting practices, provide a sampling of fee structur...
Aligning oversize/overweight fees with agency costs : critical issues.
DOT National Transportation Integrated Search
2013-08-01
This project provides an elementary analysis of issues and a proposed framework for the state to evaluate cost recovery options : due to OSOW operations. The authors provide a review of current permitting practices, provide a sampling of fee structur...
Low Vertical Clearance Truss Bridges : Risk Assessment and Retrofit Mitigation Study
DOT National Transportation Integrated Search
2017-11-10
The Washington State Department of Transportation (WSDOT) has over 60 steel truss bridges in its inventory with vertical clearances less than the minimum 16-6 required for new bridges. This study evaluates the risks of oversized vehicle impacts...
17. Photocopy of c. 1922 photograph of cane field tractor ...
17. Photocopy of c. 1922 photograph of cane field tractor developed and patented by Mr. Arsenaud of Laurel Valley Plantation; Claiborne Toups, overseer, is standing on the left. - Laurel Valley Sugar Plantation, State Route 308, Thibodaux, Lafourche Parish, LA
DOT National Transportation Integrated Search
2005-02-01
This report presents STRUCTVIEW, a vehicle-based system for the measurement of roadway structure proles, which uses a scanning laser rangender to measure various structure and roadway features while traveling at highway speed. Measurement capab...
Analysis of impact energy to fracture un-notched charpy specimens made from railroad tank car steel
DOT National Transportation Integrated Search
2007-09-11
This paper describes a nonlinear finite element analysis : (FEA) framework that examines the impact energy to fracture : unnotched Charpy specimens by an oversized, nonstandard : pendulum impactor called the Bulk Fracture Charpy Machine : (BFCM). The...
Estimating design discharges for drainage structures in western Kansas : [summary].
DOT National Transportation Integrated Search
2013-06-01
KDOT engineers have expressed concern that the hydrologic methods in the current KDOT Design Manual (Volume I, Part C, 2011) may lead to over-sizing of drainage structures in Western Kansas. Some new structures designed by the current methods are muc...
Analysis of a Stand-Alone Power System for Remote-Site Applications
1986-05-01
ratio ......................... 7.5 C at rated output .................... 0.41 Bade material ......... ........... laminated wood composite Hub Material...steel lifting cables or slings and spreader bars are required (3) continental overland travel requires a flatbed truck with over-size travel permits
Development of a proposed overweight vehicle permit fee structure in Illinois.
DOT National Transportation Integrated Search
2017-02-01
Permits are one of the most effective and common tools for state agencies to regulate the operation of overweight and : oversize vehicles by ensuring the safety of passenger and freight traffic and minimizing damage to pavements and : bridges while p...
Murphy, Ryan J; Liacouras, Peter C; Grant, Gerald T; Wolfe, Kevin C; Armand, Mehran; Gordon, Chad R
2016-11-01
Craniomaxillofacial reconstruction with patient-specific, customized craniofacial implants (CCIs) is ideal for skeletal defects involving areas of aesthetic concern-the non-weight-bearing facial skeleton, temporal skull, and/or frontal-forehead region. Results to date are superior to a variety of "off-the-shelf" materials, but require a protocol computed tomography scan and preexisting defect for computer-assisted design/computer-assisted manufacturing of the CCI. The authors developed a craniomaxillofacial surgical assistance workstation to address these challenges and intraoperatively guide CCI modification for an unknown defect size/shape. First, the surgeon designed an oversized CCI based on his/her surgical plan. Intraoperatively, the surgeon resected the bone and digitized the resection using a navigation pointer. Next, a projector displayed the limits of the craniofacial bone defect onto the prefabricated, oversized CCI for the size modification process; the surgeon followed the projected trace to modify the implant. A cadaveric study compared the standard technique (n = 1) to the experimental technique (n = 5) using surgical time and implant fit. The technology reduced the time and effort needed to resize the oversized CCI by an order of magnitude as compared with the standard manual resizing process. Implant fit was consistently better for the computer-assisted case compared with the control by at least 30%, requiring only 5.17 minutes in the computer-assisted cases compared with 35 minutes for the control. This approach demonstrated improvement in surgical time and accuracy of CCI-based craniomaxillofacial reconstruction compared with previously reported methods. The craniomaxillofacial surgical assistance workstation will provide craniofacial surgeons a computer-assisted technology for effective and efficient single-stage reconstruction when exact craniofacial bone defect sizes are unknown.
Lung size mismatch and primary graft dysfunction after bilateral lung transplantation *
Eberlein, Michael; Reed, Robert M.; Bolukbas, Servet; Wille, Keith M.; Orens, Jonathan B.; Brower, Roy G.; Christie, Jason D.
2014-01-01
BACKGROUND Donor to recipient lung size matching at lung transplantation (LTx) can be estimated by the predicted total lung capacity (pTLC)ratio (donor pTLC/recipient pTLC). We aimed to determine whether the pTLC-ratio is associated with the risk of primary graft dysfunction (PGD) after bilateral LTx (BLT). METHODS We calculated the pTLC-ratio for 812 adult BLTs from the Lung Transplant Outcomes Group between 3/2002-12/2010. Patients were stratified by pTLC-ratio>1.0 (“oversized”) and pTLC-ratio≤1.0 (“undersized”). PGD was defined as any ISHLT grade 3 PGD within 72 hours of reperfusion (PGD 3). We analyzed the association between risk factors and PGD using multivariable conditional logistic regression. As transplant diagnoses can influence the size matching decisions and also modulate the risk for PGD, we performed pre-specified analyses by assessing the impact of lung size mismatch within diagnostic categories. RESULTS In univariate analyses oversizing was associated with a 39% lower odds of PGD3 (OR 0.61, 95% CI, p=0.003). In a multivariate model accounting for center effects and known PGD risks, oversizing remained independently associated with a decreased odds of PGD3 (OR 0.58, 95% CI 0.38-0.88, p=0.01). The risk adjusted point estimate was similar for the non-COPD diagnoses groups (OR 0.52, 95%CI 0.32-0.86, p=0.01); however there was no detected association within the COPD group (OR 0.72, 95% CI 0.29-1.78, p=0.5). CONCLUSION Oversized allografts are associated with a decreased risk of PGD3 after BLT; this effect appears most apparent in non-COPD patients. PMID:25447586
Performance of a large building rainwater harvesting system.
Ward, S; Memon, F A; Butler, D
2012-10-15
Rainwater harvesting is increasingly becoming an integral part of the sustainable water management toolkit. Despite a plethora of studies modelling the feasibility of the utilisation of rainwater harvesting (RWH) systems in particular contexts, there remains a significant gap in knowledge in relation to detailed empirical assessments of performance. Domestic systems have been investigated to a limited degree in the literature, including in the UK, but there are few recent longitudinal studies of larger non-domestic systems. Additionally, there are few studies comparing estimated and actual performance. This paper presents the results of a longitudinal empirical performance assessment of a non-domestic RWH system located in an office building in the UK. Furthermore, it compares actual performance with the estimated performance based on two methods recommended by the British Standards Institute - the Intermediate (simple calculations) and Detailed (simulation-based) Approaches. Results highlight that the average measured water saving efficiency (amount of mains water saved) of the office-based RWH system was 87% across an 8-month period, due to the system being over-sized for the actual occupancy level. Consequently, a similar level of performance could have been achieved using a smaller-sized tank. Estimated cost savings resulted in capital payback periods of 11 and 6 years for the actual over-sized tank and the smaller optimised tank, respectively. However, more detailed cost data on maintenance and operation is required to perform whole life cost analyses. These findings indicate that office-scale RWH systems potentially offer significant water and cost savings. They also emphasise the importance of monitoring data and that a transition to the use of Detailed Approaches (particularly in the UK) is required to (a) minimise over-sizing of storage tanks and (b) build confidence in RWH system performance. Copyright © 2012 Elsevier Ltd. All rights reserved.
Home Sewage Disposal. Special Circular 212.
ERIC Educational Resources Information Center
Wooding, N. Henry
This circular provides current information for homeowners who must repair or replace existing on-lot sewage disposal systems. Site requirements, characteristics and preparation are outlined for a variety of alternatives such as elevated sand mounds, sand-lined beds and trenches, and oversized absorption area. Diagrams indicating construction…
Mechanistic-Based Pavement Damage Associated Cost from Oversize and Overweight Vehicles in Nevada.
DOT National Transportation Integrated Search
2017-10-16
The movement of overweight (OW) vehicles has become more common over the years due to its vital necessity for many important industries such as chemical, oil, defense, etc. Using OW vehicles reduces the number of vehicles on highways, potentially dec...
DOT National Transportation Integrated Search
2017-01-01
The project developed a process to evaluate potential oversize/overweight (OS/OW) freight corridors that will serve Texas coastal port regions and border ports of entry (POEs); such evaluations provide valuable input during legislative inquiries and ...
FIELD-SCALE STUDIES: HOW DOES SOIL SAMPLE PRETREATMENT AFFECT REPRESENTATIVENESS ? (ABSTRACT)
Samples from field-scale studies are very heterogeneous and can contain large soil and rock particles. Oversize materials are often removed before chemical analysis of the soil samples because it is not practical to include these materials. Is the extracted sample representativ...
FIELD-SCALE STUDIES: HOW DOES SOIL SAMPLE PRETREATMENT AFFECT REPRESENTATIVENESS?
Samples from field-scale studies are very heterogeneous and can contain large soil and rock particles. Oversize materials are often removed before chemical analysis of the soil samples because it is not practical to include these materials. Is the extracted sample representativ...
Economics of oversized cyclones in the cotton ginning industry
USDA-ARS?s Scientific Manuscript database
Cost of reducing pollution to meet increasingly stringent air quality standards particularly for the U.S. cotton ginning industry is rising overtime. Most industry participants use cyclones to control air pollutants. These cyclones have no moving parts and their initial investment costs are relative...
Haga, Yutaka; Dominique, Vincent J; Du, Shao Jun
2009-10-01
To characterize the process of vertebral segmentation and disc formation in living animals, we analyzed tiggy-winkle hedgehog (twhh):green fluorescent protein (gfp) and sonic hedgehog (shh):gfp transgenic zebrafish models that display notochord-specific GFP expression. We found that they showed distinct patterns of expression in the intervertebral discs of late stage fish larvae and adult zebrafish. A segmented pattern of GFP expression was detected in the intervertebral disc of twhh:gfp transgenic fish. In contrast, little GFP expression was found in the intervertebral disc of shh:gfp transgenic fish. Treating twhh:gfp transgenic zebrafish larvae with exogenous retinoic acid (RA), a teratogenic factor on normal development, resulted in disruption of notochord segmentation and formation of oversized vertebrae. Histological analysis revealed that the oversized vertebrae are likely due to vertebral fusion. These studies demonstrate that the twhh:gfp transgenic zebrafish is a useful model for studying vertebral segmentation and disc formation, and moreover, that RA signaling may play a role in this process.
Explaining body size beliefs in anorexia.
Gadsby, Stephen
2017-11-01
Cognitive neuropsychiatry has had much success in providing theoretical models for the causal origins of many delusional beliefs. Recently, it has been suggested that some anorexia nervosa patients' beliefs about their own body size should be considered delusions. As such, it seems high time the methods of cognitive neuropsychiatry were turned to modelling the false body size beliefs of anorexics. In this paper, I adopt an empiricist approach to modelling the causal origins of false body size beliefs in anorexia. Within the background of cognitive neuropsychiatry, empiricist models claim that abnormal beliefs are grounded by abnormal experiences bearing similar content. I discuss the kinds of abnormal experiences of body size anorexics suffer from which could ground their false beliefs about body size. These oversized experiences come in three varieties: false self-other body comparisons, spontaneous mental imagery of a fat body and distorted perception of affordances. Further theoretical and empirical research into the oversized experiences which anorexics suffer from presents a promising avenue for understanding and treating the disorder.
Code of Federal Regulations, 2011 CFR
2011-07-01
... washing process which is designed and operated at all times such that the product is saturated with water. ... series of idlers and routed around a pulley at each end. Bucket elevator means a conveying device of... (screens) in series, and retaining oversize material on the mesh surfaces (screens). Grizzly feeders...
Code of Federal Regulations, 2012 CFR
2012-07-01
... washing process which is designed and operated at all times such that the product is saturated with water. ... series of idlers and routed around a pulley at each end. Bucket elevator means a conveying device of... (screens) in series, and retaining oversize material on the mesh surfaces (screens). Grizzly feeders...
Code of Federal Regulations, 2010 CFR
2010-07-01
... washing process which is designed and operated at all times such that the product is saturated with water. ... series of idlers and routed around a pulley at each end. Bucket elevator means a conveying device of... (screens) in series, and retaining oversize material on the mesh surfaces (screens). Grizzly feeders...
Code of Federal Regulations, 2014 CFR
2014-07-01
... washing process which is designed and operated at all times such that the product is saturated with water. ... series of idlers and routed around a pulley at each end. Bucket elevator means a conveying device of... (screens) in series, and retaining oversize material on the mesh surfaces (screens). Grizzly feeders...
Code of Federal Regulations, 2013 CFR
2013-07-01
... washing process which is designed and operated at all times such that the product is saturated with water. ... series of idlers and routed around a pulley at each end. Bucket elevator means a conveying device of... (screens) in series, and retaining oversize material on the mesh surfaces (screens). Grizzly feeders...
Take a Bite Out of Teenage Cavities!
ERIC Educational Resources Information Center
Kerr, Joanne
2004-01-01
Many people probably remember the oral hygiene presentation in school when an oversized toothbrush and "Mr. Tooth"demonstrated proper brushing techniques. Red disclosing tablets were chewed after brushing, and then friends were amazed with our poor dental habits! The point is that presentation was remembered. Middle school students today need a…
78 FR 57208 - Notice of Passenger Facility Charge (PFC) Approvals and Disapprovals
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-17
... LEVEL: End of runway deicing program--phase 1, runway 34R. Taxiway S pavement reconstruction. Replace carousel 9 and oversized bag belt TU3. Terminal redevelopment program--design and associated technical... APPROVED FOR COLLECTION AND USE: PFC program administration. Design taxiways A, L and B. BRIEF DESCRIPTION...
The President's Report, 1983-84.
ERIC Educational Resources Information Center
Bok, Derek
The 1983-84 annual report of the President of Harvard University to members of the Board of Overseers addresses the advantages and disadvantages of the utilization of new technologies by a university, comments on the instructional uses of computers (including computer assisted instruction (CAI)) and video technology, and cites specific examples in…
ERIC Educational Resources Information Center
Wright, Betty Atwell
The Rural Education Studies albums (oversized photographs printed on heavy coated cardboard) are published in a set of 8, each of which has a separate teacher's guide to complement the contents. A comprehensive teacher's guide provides background studies for effective use of the series, as well as providing specific information and key-concepts…
DOT National Transportation Integrated Search
2003-05-01
To accelerate the modernization and improve the performance of the air traffic control system, the Wendell H. Ford Aviation Investment and Reform Act for the 21st Century (AIR-21) created the Air Traffic Services Subcommittee (subcommittee) to overse...
Publications - RI 2001-1A | Alaska Division of Geological & Geophysical
content DGGS RI 2001-1A Publication Details Title: Bedrock geologic map of the Chulitna region the Chulitna region, southcentral Alaska: Alaska Division of Geological & Geophysical Surveys ; Other Oversized Sheets Sheet 1 Bedrock geologic map of the Chulitna region, southcentral Alaska, scale 1
Priorite a la comprehension ecrite (Priority for Reading Comprehension).
ERIC Educational Resources Information Center
Santos, Anna Maria Lucena V.; And Others
1991-01-01
After finding that French language learning was declining in Rio de Janeiro schools because of inadequate resources, oversized classes, and irrelevant curricula, several teachers turned to a magazine for adolescents for motivating students to read. Extracts from an article and a series of exercises developing varied competencies illustrate the…
77 FR 29214 - Airworthiness Directives; Hawker Beechcraft Corporation Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-17
...), DOT. ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for certain... oversized clamps on fuel vapor return and/ or fuel vent lines in the outboard sections of the left and right...-140, 1200 New Jersey Avenue SE., Washington, DC 20590. FOR FURTHER INFORMATION CONTACT: Thomas Teplik...
Pilot plant experience on anaerobic codigestion of source selected OFMSW and sewage sludge.
Cabbai, Valentina; De Bortoli, Nicola; Goi, Daniele
2016-03-01
Anaerobic codigestion of source selected organic fraction of municipal solid waste (SS-OFMSW) and sewage sludge may be one of the most viable solutions to optimize oversized digesters efficiency in wastewater treatment plants. Based on results of BMP tests obtained for sewage sludge and SS-OFMSW, pilot plant tests were carried out by 3.4 m(3) CSTR reactor at mesophilic temperature. A mix of fruit and vegetable waste from wholesale market and canteen waste was used as SS-OFMSW substrate. Tests were conducted applying an OLR (organic loading rate) ramp with 6 different phases until a value of 3.2 kgVS/m(3) d. Feedstock and digestate characteristics, efficiency and process parameters were monitored. The anaerobic codigestion development was stable in each phase: early indicators like VFA (volatile fatty acids) and FOS/TAC ratio were always below instability threshold values. The maximum OLR tested determined a GPR (gas production rate) of 0.95 N m(3)/m(3) d and SGP (specific gas production) of 0.49 N m(3)/kgVS with a VS abatement of 67.3%. Copyright © 2015 Elsevier Ltd. All rights reserved.
Multivariable Techniques for High-Speed Research Flight Control Systems
NASA Technical Reports Server (NTRS)
Newman, Brett A.
1999-01-01
This report describes the activities and findings conducted under contract with NASA Langley Research Center. Subject matter is the investigation of suitable multivariable flight control design methodologies and solutions for large, flexible high-speed vehicles. Specifically, methodologies are to address the inner control loops used for stabilization and augmentation of a highly coupled airframe system possibly involving rigid-body motion, structural vibrations, unsteady aerodynamics, and actuator dynamics. Design and analysis techniques considered in this body of work are both conventional-based and contemporary-based, and the vehicle of interest is the High-Speed Civil Transport (HSCT). Major findings include: (1) control architectures based on aft tail only are not well suited for highly flexible, high-speed vehicles, (2) theoretical underpinnings of the Wykes structural mode control logic is based on several assumptions concerning vehicle dynamic characteristics, and if not satisfied, the control logic can break down leading to mode destabilization, (3) two-loop control architectures that utilize small forward vanes with the aft tail provide highly attractive and feasible solutions to the longitudinal axis control challenges, and (4) closed-loop simulation sizing analyses indicate the baseline vane model utilized in this report is most likely oversized for normal loading conditions.
Tensile and fracture properties of type 316 stainless steel after creep
NASA Astrophysics Data System (ADS)
Gan, D.
1982-12-01
The effects of creep on the mechanical properties of type 316 stainless steel were studied. Tensile and Charpy specimens were machined from the oversize specimens crept at 750 °C and 103 MPa. The ambient fracture energy was found to deteriorate rapidly after creep. The ambient yield stress was increased moderately, but the tensile ductility was severely reduced. The effects of intergranular carbides alone on mechanical properties were studied with specimens thermal aged without load. These carbides were shown to cause a moderate reduction in fracture energy and tensile ductility but had little effect on yield stress. Extensive grain boundary separations were observed on the fracture surfaces. SEM studies showed that these grain boundaries were covered with micro voids initiated by the dense intergranular carbides. Frequently, large dimples on grain boundary joined up and initiated shear fracture into the grain. In the crept specimens additional microstructural changes in the form of intragranular carbides and subgrain boundaries were observed. Both are responsible for the increase in yield stress and the further reduction in tensile ductility and fracture energy. The intragranular carbides also modified the size and density of the dimples on the fracture surfaces.
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, to the Horizontal Integration Facility, or HIF, at Space Launch Complex 37 on Cape Canaveral Air Force Station in Florida. The upper stage and spacecraft adapter arrived with the booster on a barge at the U.S. Army Outpost wharf at Port Canaveral, and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, to the Horizontal Integration Facility, or HIF, at Space Launch Complex 37 on Cape Canaveral Air Force Station in Florida. The upper stage and spacecraft adapter arrived with the booster on a barge at the U.S. Army Outpost wharf at Port Canaveral, and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
DOT National Transportation Integrated Search
2017-08-01
To address the need for a rational but fast method to determine costs and a proposed permit fee, the research team developed the Stage 1 Expedient Analysis Method. The method was used to evaluate potential oversize/overweight (OS/OW) freight corridor...
Book of Greek Myths. A Yearling Special.
ERIC Educational Resources Information Center
d'Aulaire, Ingri; d'Aulaire, Edgar Parin
This oversized, illustrated book discusses the gods, goddesses, and legendary figures of ancient Greece in a relaxed and humorous tone to entertain, enlighten, and educate young people. The first section of the book discusses the "olden times," Gaea, and the Titans. The second section tells the story of Zeus and his family, with sections…
Alternate Methods of Effluent Disposal for On-Lot Home Sewage Systems. Special Circular 214.
ERIC Educational Resources Information Center
Wooding, N. Henry
This circular provides current information for homeowners who must repair or replace existing on-lot sewage disposal systems. Several alternatives such as elevated sand mounds, sand-lined beds and trenches and oversized absorption areas are discussed. Site characteristics and preparation are outlined. Each alternative is accompanied by a diagram…
78 FR 37152 - Airworthiness Directives; Bell Helicopter Textron Canada Limited (Bell) Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-20
... rotor (M/R) blade spar space to determine whether it is oversized and reidentifying the blade and... Blvd., Room 663, Fort Worth, Texas 76137. FOR FURTHER INFORMATION CONTACT: Sharon Miles, Aerospace... Management Group, FAA, may approve AMOCs for this AD. Send your proposal to: Sharon Miles, Aerospace Engineer...
Peseshet--the first female physician?
Harer, W B; el-Dawakhly, Z
1989-12-01
Excavation of the tomb of Akhet-Hetep at Giza revealed a monument dedicated to his mother Peseshet, who is identified by many important titles including "Overseer of Women Physicians." She is probably the world's earliest known woman physician. She practiced at the time of the building of the great pyramids in Egypt, about 2500 BC.
ERIC Educational Resources Information Center
Savarese, John
2006-01-01
The IT department has become so enmeshed in the interests and activities of the entire institution that, these days, IT requires a good deal more than an overseer. While the executive charged with leading IT is often called the chief information officer, chief information leader would now be a much better title. And that's because leaders can…
78 FR 69373 - Board of Overseers of the Malcolm Baldrige National Quality Award
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-19
... the National Institute of Standards and Technology (NIST) in administering the Malcolm Baldrige National Quality Award (Award), and information received from NIST and from the Chair of the Judges' Panel... [email protected]nist.gov . SUPPLEMENTARY INFORMATION: Authority: 15 U.S.C. 3711a(d)(2)(B) and the...
77 FR 12757 - Airworthiness Directives; Hawker Beechcraft Corporation Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-02
... rulemaking (NPRM). SUMMARY: We propose to adopt a new airworthiness directive (AD) for certain Hawker... oversized clamps on fuel vapor return and/or fuel vent lines in the outboard sections of the left and right... Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590. Hand Delivery: Deliver to Mail...
A DFT study of the stability of SIAs and small SIA clusters in the vicinity of solute atoms in Fe
NASA Astrophysics Data System (ADS)
Becquart, C. S.; Ngayam Happy, R.; Olsson, P.; Domain, C.
2018-03-01
The energetics, defect volume and magnetic properties of single SIAs and small SIA clusters up to size 6 have been calculated by DFT for different configurations like the parallel 〈110〉 dumbbell, the non parallel 〈110〉 dumbbell and the C15 structure. The most stable configurations of each type have been further analyzed to determine the influence on their stability of various solute atoms (Ti, V, Cr, Mn, Co, Ni, Cu, Mo, W, Pd, Al, Si, P), relevant for steels used under irradiation. The results show that the presence of solute atoms does not change the relative stability order among SIA clusters. The small SIA clusters investigated can bind to both undersized and oversized solutes. Several descriptors have been considered to derive interesting trends from results. It appears that the local atomic volume available for the solute is the main physical quantity governing the binding energy evolution, whatever the solute type (undersized or oversized) and the cluster configuration (size and type).
NASA Astrophysics Data System (ADS)
Hai-yang, Zhao; Min-qiang, Xu; Jin-dong, Wang; Yong-bo, Li
2015-05-01
In order to improve the accuracy of dynamics response simulation for mechanism with joint clearance, a parameter optimization method for planar joint clearance contact force model was presented in this paper, and the optimized parameters were applied to the dynamics response simulation for mechanism with oversized joint clearance fault. By studying the effect of increased clearance on the parameters of joint clearance contact force model, the relation of model parameters between different clearances was concluded. Then the dynamic equation of a two-stage reciprocating compressor with four joint clearances was developed using Lagrange method, and a multi-body dynamic model built in ADAMS software was used to solve this equation. To obtain a simulated dynamic response much closer to that of experimental tests, the parameters of joint clearance model, instead of using the designed values, were optimized by genetic algorithms approach. Finally, the optimized parameters were applied to simulate the dynamics response of model with oversized joint clearance fault according to the concluded parameter relation. The dynamics response of experimental test verified the effectiveness of this application.
Bender, Matthew T; Lin, Li-Mei; Coon, Alexander L; Colby, Geoffrey P
2017-06-14
This is a case of a high-flow, post-traumatic direct carotid-cavernous fistula with a widened arterial defect and a large-diameter internal carotid artery (ICA). The unique aspect of this case is the oversized ICA, >8mm in diameter, which is both a pathological and a therapeutic challenge, given the lack of available neuroendovascular devices for full vessel reconstruction. We present a planned two-stage embolisation paradigm for definitive treatment. Transarterial coil embolisation is performed as the first stage to disconnect the fistula and normalise flow in the ICA. A 3-month recovery period is then allowed for reduction in carotid diameter. Repair of the large vessel defect and pseudoaneurysm is performed as a second stage in a delayed fashion with a flow-diverting device. Follow-up angiography at 6 months demonstrates obliteration of the fistula and curative ICA reconstruction to a diameter <5mm. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Große Perdekamp, Markus; Glardon, Matthieu; Kneubuehl, Beat P; Bielefeld, Lena; Nadjem, Hadi; Pollak, Stefan; Pircher, Rebecca
2015-01-01
In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.
75 FR 22043 - Airworthiness Directives; Agusta S.p.A. (Agusta) Model A109E Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-27
... report of an electrical failure, an investigation revealed inadequate functioning of the 35 amperes (Amps... to replace the 35 Amps with a 50 Amps circuit breaker and replace the wires with oversized ones to... of the 35 Amps BATT BUS circuit breaker. To prevent an electrical failure, the manufacturer has...
Dielectric prisms would improve performance of quasi-optical microwave components
NASA Technical Reports Server (NTRS)
Carson, J. W.
1967-01-01
Properties of the Brewster angle and internal reflection in a dielectric prism are proposed as the basis of a new type of element for use in oversize waveguide in quasi-optical microwave components. Waveguide loss is reduced and precision broadband attenuators, phase shifters, and directional couplers can be constructed on the basis of the properties.
Making Space for Place: Mapping Tools and Practices to Teach for Spatial Justice
ERIC Educational Resources Information Center
Rubel, Laurie H.; Hall-Wieckert, Maren; Lim, Vivian Y.
2017-01-01
This article presents a set of spatial tools for classroom learning about spatial justice. As part of a larger team, we designed a curriculum that engaged 10 learners with 3 spatial tools: (a) an oversized floor map, (b) interactive geographic information systems (GIS) maps, and (c) participatory mapping. We analyze how these tools supported…
Art across the Curriculum: Out of the Box
ERIC Educational Resources Information Center
Sartorius, Tara Cady
2009-01-01
Rick Beck works in cast glass; his large-scale work ranges in scale from 15 inches to around 7 feet tall. His medium--glass--makes the scale of Beck's pieces very impressive. He is probably best-known for his oversized cast glass sculptures of common hardware: nuts, bolts, screws, measuring spoons, saws, eating utensils, eye hooks, wing nuts and…
1. EXTERIOR VIEW OF 606 LINCOLN STREET, A ONEANDAHALFSTORY CRAFTSMANSTYLE ...
1. EXTERIOR VIEW OF 606 LINCOLN STREET, A ONE-AND-A-HALF-STORY CRAFTSMAN-STYLE BUNGALOW. THIS STRUCTURE WAS BUILT AS HOUSING FOR AN OVERSEER OR MANAGER AT THE HILLSIDE COTTON MILL (1914-15). HILLSIDE WAS BUILT BY THE CALLAWAY MILLS IN SOUTHWEST LaGRANGE. - 606 Lincoln Street (House), 606 Lincoln Street, La Grange, Troup County, GA
Regional softwood sawmill processing variables as influenced by productive capacity
P. H. Steele; F. G. Wagner; K. E. Skog
The relationship between annual softwood sawmill production and lumber processing variables was examined using data from Sawmill Improvement Program (SIP) studies of 650 softwood mills. The variables were lumber recovery factor (LRF); headrig and resaw kerf width; total sawing variation, rough green size, and oversizing-undersizing for 4/4 and 8/4 lumber; planer...
46 CFR 160.171-17 - Approval testing for adult size immersion suit.
Code of Federal Regulations, 2013 CFR
2013-10-01
... equivalent synthetic socks; (v) Work shoes, if the suit is designed for shoes to be worn inside. (2) Test... Approval testing for adult size immersion suit. Caution: During each of the in-water tests prescribed in... if the oversize adult suit is of the same design as the adult suit except for extra material to...
Publications - RI 97-15C | Alaska Division of Geological & Geophysical
content DGGS RI 97-15C Publication Details Title: Surficial geologic map of the Tanana B-1 Quadrangle geologic map of the Tanana B-1 Quadrangle, central Alaska: Alaska Division of Geological & Geophysical Maps & Other Oversized Sheets Sheet 1 Surficial geologic map of the Tanana B-1 Quadrangle, Central
Bring It to Class: Unpacking Pop Culture in Literacy Learning (Grades 4 through 12)
ERIC Educational Resources Information Center
Hagood, Margaret C.; Alvermann, Donna E.; Heron-Hruby, Alison
2010-01-01
Students' backpacks bulge not just with oversize textbooks, but with paperbacks, graphic novels, street lit, and electronics such as iPods and handheld video games. This book is about unpacking those texts to explore previously unexamined assumptions regarding their usefulness to classroom learning. With a strong theoretical grounding and many…
Deck of West 232nd Street overpass, showing wide W beam ...
Deck of West 232nd Street overpass, showing wide W beam collision barrier, double-faced wooden guardrail, pedestrian fencing in front of parapet, pedestrian ramp, crosswalk, traffic light, and oversized signage, looking southeast. - Henry Hudson Parkway, Extending 11.2 miles from West 72nd Street to Bronx-Westchester border, New York County, NY
ERIC Educational Resources Information Center
Beckles, Hilary McD.
1984-01-01
During the period of slavery in the West Indies some slaves became literate. This enhanced their social status and allowed them to move into occupations such as artisan or overseer. They were well informed about the politics of the West Indies, and after emancipation they took advantage of post-slavery society. (VM)
Presentations - Lande, Lauren and others, 2015 | Alaska Division of
Details Title: A petrological model for emplacement of the ultramafic Ni-Cu-PGE Alpha complex, eastern , Newberry, R.J., and Twelker, Evan, 2015, A petrological model for emplacement of the ultramafic Ni-Cu-PGE Sheets Maps & Other Oversized Sheets Sheet 1 A petrological model for emplacement of the ultramafic
Vaginal rupture and evisceration in a dog.
Prassinos, Nikitas N; Adamama-Moraitou, Katerina K; Ververidis, Haralabos N; Anagnostou, Tilemachos L; Kladakis, Stefanos E
2010-09-01
A 1.5-year-old German Shepherd mixed breed dog was admitted with mild haemorrhage from the vulva and a perineal mass of 24-hour duration, which had been first observed immediately after parturition. Parturition had occurred at low ambient temperature, and only one puppy survived out of the seven oversized fetuses. The dog was in poor body condition, dehydrated, hypothermic, depressed, non-ambulatory and in a state of shock. Intestinal loops, the urinary bladder and the uterine horns and body were protruding from the vulva. A true vaginal prolapse was also observed. The abdominal viscera were flushed with warm sterile saline solution, protected and maintained wet. The laboratory findings included moderate anaemia, leukocytosis, hypoalbuminaemia, azotaemia and elevated liver enzyme activities. Stabilisation of the dog's general condition was attempted before surgery. Antimicrobial and analgesic drugs were also administered. After exploratory laparotomy the protruding organs, which were in good condition, were reduced. A recent rupture in the vaginal wall, approximately 6 cm long, was observed. Ovariohysterectomy and partial vaginectomy were performed. The preoperative course of therapy was continued, but the bitch died 12 hours later. The probable cause of vaginal rupture and evisceration in this bitch was tenesmus and/or trauma due to the oversized fetuses.
Wang, Jianguo; Wang, Guangqiang; Wang, Dongyang; Li, Shuang; Zeng, Peng
2018-05-03
High power vacuum electronic devices of millimeter wave to terahertz regime are attracting extensive interests due to their potential applications in science and technologies. In this paper, the design and experimental results of a powerful compact oversized surface wave oscillator (SWO) in Y-band are presented. The cylindrical slow wave structure (SWS) with rectangular corrugations and large diameter about 6.8 times the radiation wavelength is proposed to support the surface wave interacting with annular relativistic electron beam. By choosing appropriate beam parameters, the beam-wave interaction takes place near the π-point of TM 01 mode dispersion curve, giving high coupling impedance and temporal growth rate compared with higher TM 0n modes. The fundamental mode operation of the device is verified by the particle-in-cell (PIC) simulation results, which also indicate its capability of tens of megawatts power output in the Y-band. Finally, a compact experimental setup is completed to validate our design. Measurement results show that a terahertz pulse with frequency in the range of 0.319-0.349 THz, duration of about 2 ns and radiation power of about 2.1 MW has been generated.
NASA Astrophysics Data System (ADS)
Zhenyang, Wang; Jianliang, Zhang; Gang, An; Zhengjian, Liu; Zhengming, Cheng; Junjie, Huang; Jingwei, Zhang
2016-02-01
Through analyzed and regressed the actual productive desulfurization data from the oversize blast furnace (5500 m3) in north China, the relationship between the sulfur distribution parameters and the slag composition in actual production situation was investigated. As the slag and hot metal phases have their own balance sulfur content or sulfur partial pressure in gas phase, respectively, the non-equilibrium of sulfur among gas, slag, and metal phases leads to the transmission and distribution of sulfur. Combined with sulfur transmission reactions between gas, slag and metal phases, C/CO pairs equilibrium, and Wagner model, the measured sulfide capacity can be acquired using sulfur distribution ratio, sulfur activity coefficient, and oxygen activity in hot metal. Based on the theory of congregated electron phase, a new sulfide capacity prediction model (CEPM) has been developed, which has a good liner relationship with the measured sulfide capacity. Thus, using the burden structure for BF, the ironmaking slag composition can be obtained simply and can be used to reliably predict the ironmaking slag desulfurization ability a few hours later after charging under a certain temperature by CEPM.
Le Cann, Sophie; Galland, Alexandre; Rosa, Benoît; Le Corroller, Thomas; Pithioux, Martine; Argenson, Jean-Noël; Chabrand, Patrick; Parratte, Sébastien
2014-09-01
Most acetabular cups implanted today are press-fit impacted cementless. Anchorage begins with the primary stability given by insertion of a slightly oversized cup. This primary stability is key to obtaining bone ingrowth and secondary stability. We tested the hypothesis that primary stability of the cup is related to surface roughness of the implant, using both an experimental and a numerical models to analyze how three levels of surface roughness (micro, macro and combined) affect the primary stability of the cup. We also investigated the effect of differences in diameter between the cup and its substrate, and of insertion force, on the cups' primary stability. The results of our study show that primary stability depends on the surface roughness of the cup. The presence of macro-roughness on the peripheral ring is found to decrease primary stability; there was excessive abrasion of the substrate, damaging it and leading to poor primary stability. Numerical modeling indicates that oversizing the cup compared to its substrate has an impact on primary stability, as has insertion force. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Brophy-Williams, Ned; Driller, Matthew William; Shing, Cecilia Mary; Fell, James William; Halson, Shona Leigh; Halson, Shona Louise
2015-01-01
The purpose of this investigation was to measure the interface pressure exerted by lower body sports compression garments, in order to assess the effect of garment type, size and posture in athletes. Twelve national-level boxers were fitted with sports compression garments (tights and leggings), each in three different sizes (undersized, recommended size and oversized). Interface pressure was assessed across six landmarks on the lower limb (ranging from medial malleolus to upper thigh) as athletes assumed sitting, standing and supine postures. Sports compression leggings exerted a significantly higher mean pressure than sports compression tights (P < 0.001). Oversized tights applied significantly less pressure than manufacturer-recommended size or undersized tights (P < 0.001), yet no significant differences were apparent between different-sized leggings. Standing posture resulted in significantly higher mean pressure application than a seated posture for both tights and leggings (P < 0.001 and P = 0.002, respectively). Pressure was different across landmarks, with analyses revealing a pressure profile that was neither strictly graduated nor progressive in nature. The pressure applied by sports compression garments is significantly affected by garment type, size and posture assumed by the wearer.
Dual-stroke heat pump field performance
NASA Astrophysics Data System (ADS)
Veyo, S. E.
1984-11-01
Two nearly identical proprototype systems, each employing a unique dual-stroke compressor, were built and tested. One was installed in an occupied residence in Jeannette, Pa. It has provided the heating and cooling required from that time to the present. The system has functioned without failure of any prototypical advanced components, although early field experience did suffer from deficiencies in the software for the breadboard micro processor control system. Analysis of field performance data indicates a heating performance factor (HSPF) of 8.13 Stu/Wa, and a cooling energy efficiency (SEER) of 8.35 Scu/Wh. Data indicate that the beat pump is oversized for the test house since the observed lower balance point is 3 F whereas 17 F La optimum. Oversizing coupled with the use of resistance heat ot maintain delivered air temperature warmer than 90 F results in the consumption of more resistance heat than expected, more unit cycling, and therefore lower than expected energy efficiency. Our analysis indicates that with optimal mixing the dual stroke heat pump will yield as HSFF 30% better than a single capacity heat pump representative of high efficiency units in the market place today for the observed weather profile.
A preliminary analysis of recent HVAC energy projects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaddy, P.J.; Haake, C.F.
A typical Government HVAC design over the last 30 years consisted of two oversized (equal tonnage) electric chillers, two oversized (equal NBTU ratings) boilers, an air economizer cycle, a constant air volume system and a central station pneumatic control system. This typical basic layout for plant design has certain advantages such as simplicity and ease to construct throughout the country. The cookie cutter design/build approach suited federal facilities, when utility costs were not a major consideration, in-house maintenance and operations personnel were plentiful and energy conservation was a moral priority and not an economic concern. Those days are history asmore » energy costs have escalated and operating budgets continue to shrink leaving fewer personnel to maintain the same buildings. Advances in HVAC technology and the reduction in costs for energy efficient systems have finally started affecting the Federal Government`s HVAC replacement and new construction designs. This paper is a brief description of three HVAC projects that go outside the traditional government HVAC design parameters. GSA`s Pacific Rim Region, covering the states of Hawaii, California, Nevada, and Arizona, has implemented three HVAC projects utilizing different technologies not normally found in GSA Federal facilities.« less
THz and Sub-THz Capabilities of a Table-Top Radiation Source Driven by an RF Thermionic Electron Gun
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smirnov, Alexei V.; Agustsson, R.; Boucher, S.
Design features and experimental results are presented for a sub-mm wave source [1] based on APS RF thermionic electron gun. The setup includes compact alpha-magnet, quadrupoles, sub-mm-wave radiators, and THz optics. The sub-THz radiator is a planar, oversized structure with gratings. Source upgrade for generation frequencies above 1 THz is discussed. The THz radiator will use a short-period undulator having 1 T field amplitude, ~20 cm length, and integrated with a low-loss oversized waveguide. Both radiators are integrated with a miniature horn antenna and a small ~90°-degree in-vacuum bending magnet. The electron beamline is designed to operate different modes includingmore » conversion to a flat beam interacting efficiently with the radiator. The source can be used for cancer diagnostics, surface defectoscopy, and non-destructive testing. Sub-THz experiment demonstrated a good potential of a robust, table-top system for generation of a narrow bandwidth THz radiation. This setup can be considered as a prototype of a compact, laser-free, flexible source capable of generation of long trains of Sub-THz and THz pulses with repetition rates not available with laser-driven sources.« less
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, into the Horizontal Integration Facility, or HIF, at Space Launch Complex 37 on Cape Canaveral Air Force Station in Florida. The port booster joins the other two boosters of the Delta IV Heavy already in the HIF. The upper stage and spacecraft adapter arrived with the booster on a barge at the U.S. Army Outpost wharf at Port Canaveral, and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, into the Horizontal Integration Facility, or HIF, at Space Launch Complex 37 on Cape Canaveral Air Force Station in Florida. The port booster joins the other two boosters of the Delta IV Heavy already in the HIF. The upper stage and spacecraft adapter arrived with the booster on a barge at the U.S. Army Outpost wharf at Port Canaveral, and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, to Space Launch Complex 37 on Cape Canaveral Air Force Station after it was offloaded from the barge at the U.S. Army Outpost wharf at Port Canaveral in Florida. The booster will be transported to the Horizontal Integration Facility, or HIF, at the launch complex. The upper stage and spacecraft adapter arrived with the booster and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, to Space Launch Complex 37 on Cape Canaveral Air Force Station after it was offloaded from the barge at the U.S. Army Outpost wharf at Port Canaveral in Florida. The booster will be transported to the Horizontal Integration Facility, or HIF, at the launch complex. The upper stage and spacecraft adapter arrived with the booster and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, into the Horizontal Integration Facility, or HIF, at Space Launch Complex 37 on Cape Canaveral Air Force Station in Florida. The port booster joins the other two boosters of the Delta IV Heavy already in the HIF. The upper stage and spacecraft adapter arrived with the booster on a barge at the U.S. Army Outpost wharf at Port Canaveral, and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, to Space Launch Complex 37 on Cape Canaveral Air Force Station after it was offloaded from the barge at the U.S. Army Outpost wharf at Port Canaveral in Florida. The booster will be transported to the Horizontal Integration Facility, or HIF, at the launch complex. The upper stage and spacecraft adapter arrived with the booster and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
2014-05-07
CAPE CANAVERAL, Fla. -- A transporter for oversize loads carries the port booster for the United Launch Alliance Delta IV Heavy for Exploration Flight Test-1, or EFT-1, to Space Launch Complex 37 on Cape Canaveral Air Force Station after it was offloaded from the barge at the U.S. Army Outpost wharf at Port Canaveral in Florida. The booster will be transported to the Horizontal Integration Facility, or HIF, at the launch complex. The upper stage and spacecraft adapter arrived with the booster and were transported to the HIF on May 6. At the HIF, all three booster stages will be processed and checked out before being moved to the nearby launch pad and hoisted into position. The spacecraft adapter will connect Orion to the ULA Delta IV, and also will connect Orion to NASA's new rocket, the Space Launch System, on its first mission in 2017. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on EFT-1 is planned for fall 2014. Photo credit: NASA/Kim Shiflett
Publications - AR 1981-82 | Alaska Division of Geological & Geophysical
Oversized Sheets Plate 1 Significant mineral deposits and prospects in Alaska (9.7 M) Plate 2 Major active claim blocks and development projects in Alaska, scale 1:2,500,000 (22.0 M) Plate 3 Mining claim recording districts of Alaska, scale 1:500,000 (6.9 M) Plate 4 Peat resource map of Alaska, scale 1
The usefulness of a stretch-polyester pouch to encase implanted pacemakers and defibrillators.
Parsonnet, V; Bernstein, A D; Neglia, D; Omar, A
1994-12-01
This study was undertaken to assess the effects of enclosing permanent pacemaker and ICD pulse generators in a stretch-polyester pouch prior to implantation. Follow-up of 223 patients with oversized pacemakers and with ICDs and 344 with standard-sized pacemaker pulse generators showed that the pouch was effective in decreasing the frequency of pulse generator migration and extrusion.
Code of Federal Regulations, 2010 CFR
2010-01-01
... of Carpets and Rugs (FF 1-70) at § 1630.4(b)(1)(ii) provides that if a carpet or rug has had a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the sample or oversized... specimens either 10 times under the washing and drying procedure prescribed in Method 124-1996 of the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... of Carpets and Rugs (FF 1-70) at § 1630.4(b)(1)(ii) provides that if a carpet or rug has had a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the sample or oversized... specimens either 10 times under the washing and drying procedure prescribed in Method 124-1996 of the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... of Carpets and Rugs (FF 1-70) at § 1630.4(b)(1)(ii) provides that if a carpet or rug has had a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the sample or oversized... specimens either 10 times under the washing and drying procedure prescribed in Method 124-1996 of the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... of Carpets and Rugs (FF 1-70) at § 1630.4(b)(1)(ii) provides that if a carpet or rug has had a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the sample or oversized... specimens either 10 times under the washing and drying procedure prescribed in Method 124-1996 of the...
Heat Exchange with Air and Temperature Profile of a Moving Oversize Tire
NASA Astrophysics Data System (ADS)
Grinchuk, P. S.; Fisenko, S. P.
2016-11-01
A one-dimensional mathematical model of heat transfer in a tire with account for the deformation energy dissipation and heat exchange of a moving tire with air has been developed. The mean temperature profiles are calculated and transition to a stationary thermal regime is considered. The influence of the rate of energy dissipation and of effective thermal conductivity of rubber on the temperature field is investigated quantitatively.
NASA Astrophysics Data System (ADS)
Liu, Lu; Kamm, Paul; García-Moreno, Francisco; Banhart, John; Pasini, Damiano
2017-10-01
This paper examines three-dimensional metallic lattices with regular octet and rhombicuboctahedron units fabricated with geometric imperfections via Selective Laser Sintering. We use X-ray computed tomography to capture morphology, location, and distribution of process-induced defects with the aim of studying their role in the elastic response, damage initiation, and failure evolution under quasi-static compression. Testing results from in-situ compression tomography show that each lattice exhibits a distinct failure mechanism that is governed not only by cell topology but also by geometric defects induced by additive manufacturing. Extracted from X-ray tomography images, the statistical distributions of three sets of defects, namely strut waviness, strut thickness variation, and strut oversizing, are used to develop numerical models of statistically representative lattices with imperfect geometry. Elastic and failure responses are predicted within 10% agreement from the experimental data. In addition, a computational study is presented to shed light into the relationship between the amplitude of selected defects and the reduction of elastic properties compared to their nominal values. The evolution of failure mechanisms is also explained with respect to strut oversizing, a parameter that can critically cause failure mode transitions that are not visible in defect-free lattices.
Modelling of sequential groundwater treatment with zero valent iron and granular activated carbon.
Bayer, Peter; Finkel, Michael
2005-06-01
Multiple contaminant mixtures in groundwater may not efficiently be treated by a single technology if contaminants possess rather different properties with respect to sorptivity, solubility, and degradation potential. An obvious choice is to use sequenced units of the generally accepted treatment materials zero valent iron (ZVI) and granular activated carbon (GAC). However, as the results of this modelling study suggest, the required dimensions of both reactor units may strongly differ from those expected on the grounds of a contaminant-specific design. This is revealed by performing an analysis for a broad spectrum of design alternatives through numerical experiments for selected patterns of contaminant mixtures consisting of monochlorobenzene, tetrachloroethylene, trichloroethylene (TCE), cis-1,2-dichloroethylene (cis-DCE), and vinyl chloride (VC). It is shown that efficient treatment can be achieved only if competitive sorption effects in the GAC unit as well as the formation of intermediate products in the ZVI unit are carefully taken into account. Cost-optimal designs turned out to vary extremely depending on the prevailing conditions concerning contaminant concentrations, branching ratios, and unit costs of both reactor materials. Where VC is the critical contaminant, due to high initial concentration or extensive production as an intermediate, two options are cost-effective: an oversized ZVI unit with an oversized GAC unit or a pure GAC reactor.
Photographic copy of July 30, 1934 black and white photograph. ...
Photographic copy of July 30, 1934 black and white photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. 1934 PHOTOGRAPH OF PIER IV LOOKING NORTHWEST FROM BEST BANK TOWARD EAST BANK. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of early black and white photograph. Located loose ...
Photographic copy of early black and white photograph. Located loose in oversized box at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. EARLY PHOTOGRAPH OF BRIDGE TAKEN FROM WEST BANK APPROACH LOOKING NORTH TOWARD EAST BANK. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Publications - PDF 95-33B | Alaska Division of Geological & Geophysical
D-1, C-1, and part of the B-1 quadrangles, east-central Alaska Authors: Clough, J.G., Mull, C.G , Interpretive bedrock geologic map of the Charley River D-1, C-1, and part of the B-1 quadrangles, east-central 1:63,360. http://doi.org/10.14509/1713 Publication Products Maps & Other Oversized Sheets Maps
Internal Prosthetic Replacement of Skeletal Segments Lost in Combat Injuries.
1973-08-31
osteo- articular bone grafts. Clin. Ortho., 87: 156, 1972. 8. Tuli, S. M.: Bridging of bone defects by massive bone grafts in tumorous conditions. Clin...fashion in its proximal one-third to "prevent distractic ,n of the fragments. The fiber metal segment was then placed in the appropriate defect and the...defect slightly oversized and also osteotomizing the fibula to delete any possible distracting forces or angulating forces. The only complication in
Lying to Ourselves: Dishonesty in the Army Profession
2015-02-01
nature of land warfare; • Matters affecting the Army’s future; • The concepts, philosophy, and theory of strategy; and, • Other issues of importance...morally wrong behavior into socially acceptable conduct by dimming the glare and guilt of the ethical spotlight. One factor that encourages ethical...placating the Army bureaucracy or civilian overseers by telling them what they want to hear. As a result, Army leaders learn to talk of one world
USCINCPAC: Now and in the Future
1990-04-01
other nations , while the Disaster Relief Act of 1974 applies to US territories, which includes American Samoa, Guam, the Commonwealth of the Northern...appearing to be American puppets. Some South Pacific nations see the Australians as overseers and have alienated themselves from the Aussies. (3:17...Pacific and Indian Ocean remions? First , the Command must continue to think more about what it will be like to live in a world of multiple power centers and
Code of Federal Regulations, 2013 CFR
2013-01-01
... of Carpets and Rugs (FF 1-70) at § 1630.4(b)(1)(ii) provides that if a carpet or rug has had a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the sample or oversized... specimens either 10 times under the washing and drying procedure prescribed in Method 124-1996 of the...
NASA Astrophysics Data System (ADS)
McKay, R. A.
1984-06-01
A 1-MW wellhead generator was tested in 1980, 1981, and 1982 by Mexico, Italy, and New Zealand at Cerro Prieto, Cesano, and Broadlands, respectively. The total flow helical screw expander portable power plant, Model 76-1, had been built for the U.S. Government and field-tested in Utah, USA, in 1978 and 1979. The expander had oversized internal clearances designed for self-cleaning operation on fluids that deposit adherent scale normally detrimental to the utiliation of liquid dominated fields. Conditions with which the expander was tested included inlet pressures of 64 to 220 psia, inlet qualities of 0% to 100%, exhaust pressures of 3.1 to 40 psia, electrial loads of idle and 110 to 933 kW, electrical frequencies of 50 and 60 Hz, male rotor speeds of 2500 to 4000 rpm, and fluid characteristics to 310,000 ppm total dissolved solids and noncondensables to 38 wt % of the vapor. Some testing was done on-grid. Typical expander isentropic efficiency was 40% to 50% with the clearances not closed, and 5 percentage points or more higher with the clearances partly closed. The expander efficiency increased approximately logarithmically with shaft power for most operations, while inlet quality, speed, and pressure ratio across the machine had only small effects. These findings are all in agreement with the Utah test results.
NASA Technical Reports Server (NTRS)
Mckay, R. A.
1984-01-01
A 1-MW wellhead generator was tested in 1980, 1981, and 1982 by Mexico, Italy, and New Zealand at Cerro Prieto, Cesano, and Broadlands, respectively. The total flow helical screw expander portable power plant, Model 76-1, had been built for the U.S. Government and field-tested in Utah, USA, in 1978 and 1979. The expander had oversized internal clearances designed for self-cleaning operation on fluids that deposit adherent scale normally detrimental to the utiliation of liquid dominated fields. Conditions with which the expander was tested included inlet pressures of 64 to 220 psia, inlet qualities of 0% to 100%, exhaust pressures of 3.1 to 40 psia, electrial loads of idle and 110 to 933 kW, electrical frequencies of 50 and 60 Hz, male rotor speeds of 2500 to 4000 rpm, and fluid characteristics to 310,000 ppm total dissolved solids and noncondensables to 38 wt % of the vapor. Some testing was done on-grid. Typical expander isentropic efficiency was 40% to 50% with the clearances not closed, and 5 percentage points or more higher with the clearances partly closed. The expander efficiency increased approximately logarithmically with shaft power for most operations, while inlet quality, speed, and pressure ratio across the machine had only small effects. These findings are all in agreement with the Utah test results.
Honey Lake Power Facility under construction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-12-01
Geothermal energy and wood waste are primary energy sources for the 30 megawatt, net, Honey Lake Power Facility, a cogeneration power plant. The facility 60% completed in January 1989, will use 1,300 tons per day of fuel obtained from selective forest thinnings and from logging residue combined with mill wastes. The power plant will be the largest industrial facility to use some of Lassen County's geothermal resources. The facility will produce 236 million kilowatt-hours of electricity annually. The plant consists of a wood-fired traveling grate furnace with a utility-type high pressure boiler. Fluids from a geothermal well will pass throughmore » a heat exchange to preheat boiler feedwater. Used geothermal fluid will be disposed of in an injection well. Steam will be converted to electrical power through a 35.5-megawatt turbine generator and transmitted 22 miles to Susanville over company-owned and maintained transmission lines. The plant includes pollution control for particulate removal, ammonia injection for removal of nitrogen oxides, and computer-controlled combustion systems to control carbon monoxide and hydrocarbons. The highly automated wood yard consists of systems to remove metal, handle oversized material, receive up to six truck loads of wood products per hour, and continuously deliver 58 tons per hour of fuel through redundant systems to ensure maximum on-line performance. The plant is scheduled to become operational in mid-1989.« less
Koenrades, Maaike A; Klein, Almar; Leferink, Anne M; Slump, Cornelis H; Geelkerken, Robert H
2018-04-01
To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort study (LSPEAS; Trialregister.nl identifier NTR4276). The patients were treated electively using an Anaconda stent-graft with a mean 31% oversizing (range 17-47). According to protocol, participants were to be followed for 2 years, during which 5 noncontrast electrocardiogram-gated computed tomography scans would be conducted. Three patients were eliminated within 30 days (1 withdrew, 1 died, and a third was converted before stent-graft deployment), leaving 15 patients (mean age 72.8±3.7 years; 14 men) for this analysis. Evolution in size and shape (symmetry) of both proximal infrarenal sealing rings were assessed from discharge to 24 months using dedicated postprocessing algorithms. At 24 months, the mean diameters of the first and second ring stents had increased significantly (first ring: 2.2±1.0 mm, p<0.001; second ring: 2.7±1.1 mm, p<0.001). At 6 months, the first and second rings had expanded to a mean 96.6%±2.1% and 94.8%±2.7%, respectively, of their nominal diameter, after which the rings expanded slowly; ring diameters stabilized to near nominal size (first ring, 98.3%±1.1%; second ring, 97.2%±1.4%) at 24 months irrespective of initial oversizing. No type I or III endoleaks or aneurysm-, device-, or procedure-related adverse events were noted in follow-up. The difference in the diametric distances between the peaks and valleys of the saddle-shaped rings was marked at discharge but became smaller after 24 months for both rings (first ring: median 2.0 vs 1.2 mm, p=0.191; second ring: median 2.8 vs 0.8 mm; p=0.013). Irrespective of initial oversizing, the Anaconda proximal sealing rings radially expanded to near nominal size within 6 months after EVAR. Initial oval-shaped rings conformed symmetrically and became nearly circular through 24 months. These findings should be taken into account in planning and follow-up.
Photographic copy of circa, 1934 black and white photograph. Loose ...
Photographic copy of circa, 1934 black and white photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. DECK TRUSS UNDER CONSTRUCTION BETWEEN PIERS C, B, AND V TAKEN AT GROUND LEVEL FROM EAST BANK. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Getting it Right: The Endurance of Improvised Explosive Device Education in the US Army
2017-05-25
platoons or companies.9 Using Rome plows—D-7 bulldozers featuring reinforced cabs and an oversized bulldozer blade with a special section used for...to those presupposed notions.21 19 Louis Yuengert, ed., How the Army Runs , 2015-2016 (Carlisle...an M60 chassis, the CEV came armed with a short-barreled 165mm cannon and an M2 machine gun, the CEV sported a bulldozer blade and an A-frame crane
43. INTERIOR VIEW, CRUSHING ADDITION. THE SYMONS VIBRATING SCREEN SITS ...
43. INTERIOR VIEW, CRUSHING ADDITION. THE SYMONS VIBRATING SCREEN SITS ON TOP OF THE PLATFORM. OVERSIZE ORE IS FED BY CHUTE TO THE GYRATORY SECONDARY CRUSHER (MISSING) SITTING ON CONCRETE FOUNDATIONS TO LOWER RIGHT. UNDERSIZE ORE WAS FED BY THE LOWER CHUTE (CENTER LEFT) TO THE 24 INCH BELT CONVEYOR UNDER THE SECONDARY CRUSHER. THE DRYER ROOM IS BEYOND. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
Publications - RI 98-12 | Alaska Division of Geological & Geophysical
content DGGS RI 98-12 Publication Details Title: Geology of the Sleetmute C-7, C-8, D-7, and D-8 ., Miller, M.L., Layer, P.W., and Laird, G.M., 1999, Geology of the Sleetmute C-7, C-8, D-7, and D-8 ; Other Oversized Sheets Sheet 1 Geologic map of the Sleetmute C-7, C-8, D-7 and D-8 quadrangles, Horn
Birnbaum, J; Ulrich, S M; Schramm, R; Hagl, C; Lehner, A; Fischer, M; Haas, N A; Heineking, B
2017-02-01
In pediatric heart transplantation, the size of the donor organ is an important criterion for organ allocation. Oversized donor hearts are often accepted with good results, but some complications in relation to a high donor-recipient ratio have been described. Our patient was transplanted for progressive heart failure in dilated cardiomyopathy. The donor-to-recipient weight ratio was 3 (donor weight 65 kg, recipient weight 22 kg). The intra-operative echocardiography before chest closure showed excellent cardiac function, no tricuspid valve regurgitation, and a normal central venous pressure. After chest closure, central venous pressure increased substantially and echocardiography revealed a severe tricuspid insufficiency. As other reasons for right ventricular dysfunction, that is, myocardial ischemia, pulmonary hypertension, and rejection, were excluded, we assumed that the insufficiency was caused by an alteration of the right ventricular geometry. After 1 week, the valve insufficiency regressed to a minimal degree. In pediatric heart transplant patients with a high donor-to-recipient weight ratio, the outlined complication may occur. If other reasons for right ventricular heart failure can be ruled out, this entity is most likely caused by an acute and transient alteration of the right ventricular geometry that may disappear over time. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Santamaría-Arrieta, Gorka; Brizuela-Velasco, Aritza; Fernández-González, Felipe J.; Chávarri-Prado, David; Chento-Valiente, Yelko; Solaberrieta, Eneko; Diéguez-Pereira, Markel; Yurrebaso-Asúa, Jaime
2016-01-01
Background This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). Material and Methods Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant stability quotient [ISQ]). Results The highest torque values were achieved by the conventional drilling technique (10mm). The ANOVA test confirmed that there was a significant correlation between torque and drilling depth (p<0.05). However, no statistically significant differences were obtained between ISQ values at 10 or 12 mm drilling depths (p>0.05) at either measurement direction (cortical and medullar). No statistical relation between torque and ISQ values was identified, or between bone density and primary stability (p >0.05). Conclusions Vertical overpreparation of the implant bed will obtain lower insertion torque values, but does not produce statistically significant differences in ISQ values. Key words:Implant stability quotient, overdrilling, primary stability, resonance frequency analysis, torque. PMID:27398182
Fatigue and durability of Nitinol stents.
Pelton, A R; Schroeder, V; Mitchell, M R; Gong, Xiao-Yan; Barney, M; Robertson, S W
2008-04-01
Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, the cyclic fatigue and durability properties of Nitinol-based endovascular stents are discussed in terms of an engineering-based experimental testing program. In this paper, the combined effects of cardiac pulsatile fatigue and stent-vessel oversizing are evaluated for application to both stents and stent subcomponents. In particular, displacement-controlled fatigue tests were performed on stent-like specimens processed from Nitinol microtubing. Fatigue data were collected with combinations of simulated oversizing conditions and pulsatile cycles that were identified by computer modeling of the stent that mimic in vivo deformation conditions. These data are analyzed with non-linear finite element computations and are illustrated with strain-life and strain-based constant-life diagrams. The utility of this approach is demonstrated in conjunction with 10 million cycle pulsatile fatigue tests of Cordis SMART Control((R)) Nitinol self-expanding stents to calculate fatigue safety factors and thereby predict in vivo fatigue resistance. These results demonstrate the non-linear constant fatigue-life response of Nitinol stents, whereby, contrary to conventional engineering materials, the fatigue life of Nitinol is observed to increase with increasing mean strain.
Photographic copy of 8 x 10 black and white photograph ...
Photographic copy of 8 x 10 black and white photograph of photograph of Franklin M. Masters (18831974). Photographer unknown: Loose in separate folder in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. PHOTOGRAPH OF FRANKLIN M. MASTERS (1883-1974). - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of 10 x 15, black and white, proof ...
Photographic copy of 10 x 15, black and white, proof photograph. Located loose in oversized box at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Photographer, The Billings Studio. PROOF PHOTOGRAPH OF COMPLETED BRIDGE TAKEN FROM WEST BANK LEVEE LOOKING NORTH DOWN RIVER TOWARD EAST BANK. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa 1933, 10 x 15 black and ...
Photographic copy of circa 1933, 10 x 15 black and white aerial photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. AERIAL PHOTOGRAPH SHOWING CONSTRUCTION OF PIERS A, I, II, AND III BEGINNING ON EAST BANK OF RIVER. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of 8 x 10 black and white photograph ...
Photographic copy of 8 x 10 black and white photograph of photograph of Ralph Modjeski (18611940). Photographer unknown: Loose in separate folder in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. PHOTOGRAPH OF RALPH MODJESKI (1861 - 1940). - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa 1933, 10 x 15 black and ...
Photographic copy of circa 1933, 10 x 15 black and white aerial photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. AERIAL PHOTOGRAPH SHOWING CONSTRUCTION OF EAST BANK RAILROAD AND BRIDGE APPROACH AT JEFFERSON HIGHWAY INTERSECTION. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa 1934, black and white photograph. Located ...
Photographic copy of circa 1934, black and white photograph. Located loose in oversized box at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. CIRCA 1934 PHOTOGRAPH TAKEN ON WEST BANK APPROACH ROADWAY LOOKING NORTHEAST TOWARD EAST BANK SHOWING DETAIL OF RAILING AND DECORATIVE LIGHT STANDARD AND FIXTURE. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa 1933, 10 x 15 black and ...
Photographic copy of circa 1933, 10 x 15 black and white aerial photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. AERIAL PHOTOGRAPH SHOWING EAST BANK CONSTRUCTION OF PIER A AND I AND COMPLETED CONSTRUCTION TRESTLE. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Implementation of in-line infrared monitor in full-scale anaerobic digestion process.
Spanjers, H; Bouvier, J C; Steenweg, P; Bisschops, I; van Gils, W; Versprille, B
2006-01-01
During start up but also during normal operation, anaerobic reactor systems should be run and monitored carefully to secure trouble-free operation, because the process is vulnerable to disturbances such as temporary overloading, biomass wash out and influent toxicity. The present method of monitoring is usually by manual sampling and subsequent laboratory analysis. Data collection, processing and feedback to system operation is manual and ad hoc, and involves high-level operator skills and attention. As a result, systems tend to be designed at relatively conservative design loading rates resulting in significant over-sizing of reactors and thus increased systems cost. It is therefore desirable to have on-line and continuous access to performance data on influent and effluent quality. Relevant variables to indicate process performance include VFA, COD, alkalinity, sulphate, and, if aerobic post-treatment is considered, total nitrogen, ammonia and nitrate. Recently, mid-IR spectrometry was demonstrated on a pilot scale to be suitable for in-line simultaneous measurement of these variables. This paper describes a full-scale application of the technique to test its ability to monitor continuously and without human intervention the above variables simultaneously in two process streams. For VFA, COD, sulphate, ammonium and TKN good agreement was obtained between in-line and manual measurements. During a period of six months the in-line measurements had to be interrupted several times because of clogging. It appeared that the sample pre-treatment unit was not able to cope with high solids concentrations all the time.
Optimal deployment of thermal energy storage under diverse economic and climate conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeForest, Nicholas; Mendes, Gonçalo; Stadler, Michael
2014-04-01
This paper presents an investigation of the economic benefit of thermal energy storage (TES) for cooling, across a range of economic and climate conditions. Chilled water TES systems are simulated for a large office building in four distinct locations, Miami in the U.S.; Lisbon, Portugal; Shanghai, China; and Mumbai, India. Optimal system size and operating schedules are determined using the optimization model DER-CAM, such that total cost, including electricity and amortized capital costs are minimized. The economic impacts of each optimized TES system is then compared to systems sized using a simple heuristic method, which bases system size as fractionmore » (50percent and 100percent) of total on-peak summer cooling loads. Results indicate that TES systems of all sizes can be effective in reducing annual electricity costs (5percent-15percent) and peak electricity consumption (13percent-33percent). The investigation also indentifies a number of criteria which drive TES investment, including low capital costs, electricity tariffs with high power demand charges and prolonged cooling seasons. In locations where these drivers clearly exist, the heuristically sized systems capture much of the value of optimally sized systems; between 60percent and 100percent in terms of net present value. However, in instances where these drivers are less pronounced, the heuristic tends to oversize systems, and optimization becomes crucial to ensure economically beneficial deployment of TES, increasing the net present value of heuristically sized systems by as much as 10 times in some instances.« less
Oversized 250 GHz Traveling Wave Tube with a Photonic Band-Gap Structure
NASA Astrophysics Data System (ADS)
Rosenzweig, Guy; Shapiro, Michael A.; Temkin, Richard J.
2017-10-01
The challenge in manufacturing traveling wave tubes (TWTs) at high frequencies is that the sizes of the structures scale with, and are much smaller than, the wavelength. We have designed and are building a 250 GHz TWT that uses an oversized structure to overcome fabrication and power handling issues that result from the small dimensions. Using a photonic band-gap (PBG) structure, we succeeded to design the TWT with a beam tunnel diameter of 0.72 mm. The circuit consists of metal plates with the beam tunnel drilled down their center. Twelve posts are protruding on one side of each plate in a triangular array and corresponding sockets are drilled on the other side. The posts of each plate are inserted into the sockets of an adjacent plate, forming a PBG lattice. The vacuum spacing between adjacent plates forms the `PBG cavity''. The full structure is a series of PBG coupled cavities, with microwave power coupling through the beam tunnel. The PBG lattice provides confinement of microwave power in each of the cavities and can be tuned to give the right amount of diffraction per cavity so that no sever is needed to suppress oscillations in the operating mode. CST PIC simulations predict over 38 dB gain with 67 W peak power, using a 30 kV, 310 mA electron beam, 0.6 mm in diameter. Research supported by the AFOSR Program on Plasma and Electro-Energetic Physics and by the NIH National Institute of Biomedical Imaging and Bioengineering.
In situ capture gamma-ray analysis of coal in an oversize borehole
Mikesell, J.L.; Dotson, D.W.; Senftle, F.E.; Zych, R.S.; Koger, J.; Goldman, L.
1983-01-01
In situ capture gamma-ray analysis in a coal seam using a high resolution gamma-ray spectrometer in a close-fitting borehole has been reported previously. In order to check the accuracy of the method under adverse conditions, similar measurements were made by means of a small-diameter sonde in an oversize borehole in the Pittsburgh seam, Greene County, Pennsylvania. The hole was 5 times the diameter of the sonde, a ratio that substantially increased the contribution of water (hydrogen) to the total spectral count and reduced the size of the sample measured by the detector. The total natural count, the 40K,count, and the intensities of capture gamma rays from Si, Ca, H, and Al were determined as a function of depth above, through, and below the coal seam. From these logs, the depth and width of the coal seam and its partings were determined. Spectra were accumulated in the seam for 1 h periods by using neutron sources of different strengths. From the spectra obtained by means of several 252Cf neutron sources of different sizes, the ultimate elemental analysis and ash content were determined. The results were not as good as those obtained previously in a close-fitting borehole. However, the results did improve with successively larger source-to-detector distances, i.e.,as the count contribution due to hydrogen in the water decreased. It was concluded that in situ borehole analyses should be made in relatively close-fitting boreholes. ?? 1983.
Shapiro, M; Raz, E; Becske, T; Nelson, P K
2014-04-01
Low-porosity endoluminal devices for the treatment of intracranial aneurysms, also known as flow diverters, have been in experimental and clinical use for close to 10 years. Despite rigorous evidence of their safety and efficacy in well-controlled trials, a number of key factors concerning their use remain poorly defined. Among these, none has received more attention to date than the debate on how many devices are optimally required to achieve a safe, effective, and economical outcome. Additional, related questions concern device sizing relative to the parent artery and optimal method of deployment of the devices. While some or all of these issues may be ultimately answered on an empiric basis via subgroup analysis of growing treatment cohorts, we believe that careful in vitro examination of relevant device properties can also help guide its in vivo use. We conducted a number of benchtop experiments to investigate the varied porosity of Pipeline Embolization Devices deployed in a simulated range of parent vessel diameters and applied these results toward conceptualizing optimal treatment strategies of fusiform and wide-neck aneurysms. The results of our studies confirm a predictable parabolic variability in device porosity based on the respective comparative sizes of the device and recipient artery, as well as device curvature. Even modest oversizing leads to a significant increase in porosity. The experiments demonstrate various deleterious effects of device oversizing relative to the parent artery and provide strategies for addressing size mismatches when they are unavoidable.
Preliminary Assessment of Overweight Mainline Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siekmann, Adam; Capps, Gary J; Lascurain, Mary Beth
2011-11-01
The Federal Motor Carrier Safety Administration requested information regarding overweight and oversized vehicle traffic entering inspection stations (ISs) in order to develop strategies for future research efforts and possibly help guide regulatory issues involving overweight commercial motor vehicles (CMVs). For a period of one month, inspection stations in Knox County and Greene County, Tennessee, recorded overweight and oversized vehicles that entered these ISs. During this period, 435 CMVs were recorded using an electronic form filled out by enforcement personnel at the IS. Of the 435 CMVs recorded, 381 had weight information documented with them. The majority (52.2%) of the vehiclesmore » recorded were five-axle combination vehicles, and 50.6% of all the vehicles were permitted to operate above the legal weight limit in Tennessee, which is 80,000 lb for vehicles with five or more axles. Only 16.8% of the CMVs recorded were overweight gross (11.5% of permitted vehicles) and 54.1% were overweight on an axle group. The low percentage of overweight gross CMVs was because only 45 of the vehicles over 80,000 lb. were not permitted. On average, axles that were overweight were 2,000 lb. over the legal limit for an axle or group of axles. Of the vehicles recorded, 172 vehicles were given a North American Standard (NAS) inspection during the assessment. Of those, 69% of the inspections were driver-only inspections (Level III) and only 25% of the inspections had a vehicle component (such as a Level I or Level II). The remaining 6% of inspections did not have valid Aspen numbers; the type of was inspection unknown. Data collected on the types of trailers of each vehicle showed that about half of the recorded CMVs could realistically be given a Level I (full vehicle and driver) inspection; this estimate was solely based on trailer type. Enforcement personnel at ISs without an inspection pit have difficulty fully inspecting certain vehicles due to low clearance below the trailer. Because of this, overweight and oversized vehicles were normally only given a Level III (driver) inspection; thus, little is known about the safety of these vehicles. The out-of-service (OOS) rate of all the inspected vehicles (driver and vehicle inspections) was 18.6%, while the OOS rate for vehicle inspections (Level I and II) was 52.4%. Future work will focus on performing Level I inspections on five-axle combination tractor-trailers and the types of violations that overweight vehicles may have. This research will be conducted in Tennessee and possibly in other states as well.« less
Towards Rural Land Use: Challenges for Oversizing Urban Perimeters in Shrinking Towns
NASA Astrophysics Data System (ADS)
Sá, João; Virtudes, Ana
2017-12-01
This article, based on the literature review, aims to study the challenges of the urban dispersion and oversizing of urban perimeters, in the cases where the towns are shrinking or spreading to the rural land-use. It is focused on the case of Portugal where during the last decades there was an escaping to the big cities alongside to the sea (Atlantic and Mediterranean) shore. In the Interior part of the country, which means near to the border with Spain, several towns are shrinking, despite their huge urban perimeters, proposed by the municipal master plans, since the middle of the nineties. Consequently, these urban perimeters are nowadays oversizing, with empty buildings and non-urbanized areas. At the same time, the social patterns of occupation of this territory have changed significantly, moving from a society with signs of rurality to an urban realm, understood not only in territorial terms but also regarding the current lifestyle. This deep changing has occurred not only in urbanistic terms but also in the economic, cultural and social organizations of the country, under a movement that corresponds to a decline of the small urban settlements in rural areas, far away from the cosmopolitan strip of land nearby the sea, in between the capital city, Lisbon and the second one Oporto. These transformations were not driven by any significant public policy for land-use actions. On the contrary, the production of urban areas, supporting the new model of economic and social development was largely left to the initiative of economic and social private agents and land owners. These agents were the leading responsible for the new urban developments and housing. In this sense, this research aims to present some strategies for the short time period regarding the devolution of urban areas to rural land use. In this sense, the next steps of spatial planning policies, under the role of local authorities (the 308 municipalities including Madeira and Azores islands, plus the continental part of the country), which are their main promoters, will be motivated by the need of advocating the swap of many urban areas towards the rural land use, shrinking many existent urban perimeters in depressed territories. How will the non-urbanized spaces, included in the urban perimeters, twenty years ago, by the pivotal instrument of spatial planning in Portugal, the Municipal Master Plans turn back to the rural land-use, losing their market value? This is the base of the challenges ahead, analysed in this article.
Characterization of ovarian follicular dynamics in dromedary camels (Camelus dromedarius).
Manjunatha, B M; Pratap, N; Al-Bulushi, Samir; Hago, B E
2012-09-15
Ovarian follicular dynamics was monitored by transrectal ultrasonography, for a period of 60 to 90 days, and its correlation with plasma estradiol-17β (E2) and progesterone (P4) were studied in seventeen, multiparous, non-lactating, 12 to 20-year-old dromedary camels. The average number of follicles recruited (12.77 ± 0.93) in each wave between animals varied (P < 0.001). The number of follicles recruited during different follicular waves was highly repeatable (0.95) within individual animals. The growth and mature phase periods of the dominant follicle (DF) were 6.10 ± 0.15 and 10.20 ± 0.47 days, respectively with a linear growth rate of 1.17 ± 0.02 mm/day between Day 0 and 10 of the follicular wave. There was an inverse relationship between the diameter of the largest DF and number of follicles (r = -0.95, P < 0.001). The DF development did not regularly alternate between the ovaries and the incidence of codominance was 45%. The mean maximum diameter of DF during its mature phase was 27.30 ± 0.78 mm and oversized follicle was 38.43 ± 1.41 mm. In 73.3% waves, the DF continued its growth for a period of 10.64 ± 1.53 days even after losing its dominance and developed into oversized follicle. The duration of the regression phase of DF and oversized follicle were 24.71 ± 3.79 and 18.50 ± 2.23 days. The mean duration of a complete follicular wave was 47.11 ± 2.94 days with an interwave interval (IWI) of 16.36 ± 0.37 days. The IWI within an individual was repeatable (0.88) and between the animals was variable (P < 0.001). Plasma E2 concentration profiles showed a wave like pattern. The peak plasma E2 concentrations were attained approximately 12 days after beginning of the growth phase, when the largest DF grew to a diameter of 18.7 mm. Plasma concentration of P4 was below 1.0 ng/mL in 85% of waves and above 1.0 ng/mL in 15% of the waves for a period of 3 to 6 days in the absence of spontaneous ovulation. It is concluded that ovarian follicular development and plasma E2 concentrations occurs in a wave like pattern in dromedary camels and the IWI and follicle numbers recruited per wave are variable between the animals and repeatable within an individual animal. Copyright © 2012 Elsevier Inc. All rights reserved.
Focal Plane Alignment Utilizing Optical CMM
NASA Technical Reports Server (NTRS)
Liebe, Carl Christian; Meras, Patrick L.; Clark, Gerald J.; Sedaka, Jack J.; Kaluzny, Joel V.; Hirsch, Brian; Decker, Todd A.; Scholtz, Christopher R.
2012-01-01
In many applications, an optical detector has to be located relative to mechanical reference points. One solution is to specify stringent requirements on (1) mounting the optical detector relative to the chip carrier, (2) soldering the chip carrier onto the printed circuit board (PCB), and (3) installing the PCB to the mechanical structure of the subsystem. Figure 1 shows a sketch of an optical detector mounted relative to mechanical reference with high positional accuracy. The optical detector is typically a fragile wafer that cannot be physically touched by any measurement tool. An optical coordinate measuring machine (CMM) can be used to position optical detectors relative to mechanical reference points. This approach will eliminate all requirements on positional tolerances. The only requirement is that the PCB is manufactured with oversized holes. An exaggerated sketch of this situation is shown in Figure 2. The sketch shows very loose tolerances on mounting the optical detector in the chip carrier, loose tolerance on soldering the chip carrier to the PCB, and finally large tolerance on where the mounting screws are located. The PCB is held with large screws and oversized holes. The PCB is mounted loosely so it can move freely around. The optical CMM measures the mechanical reference points. Based on these measurements, the required positions of the optical detector corners can be calculated. The optical CMM is commanded to go to the position where one detector corner is supposed to be. This is indicated with the cross-hairs in Figure 2(a). This figure is representative of the image of the optical CMM monitor. Using a suitable tapping tool, the PCB is manually tapped around until the corner of the optical detector is at the crosshairs of the optical CMM. The CMM is commanded to another corner, and the process is repeated a number of times until all corners of the optical detector are within a distance of 10 to 30 microns of the required position. The situation is sketched in Figure 2(b) (the figure also shows the tapping tool and where to tap). At this point the fasteners for the PCB are torqued slightly so the PCB can still move. The PCB location is adjusted again with the tapping tool. This process is repeated 3 to 4 times until the final torque is achieved. The oversized mounting holes are then filled with a liquid bonding agent to secure the board in position (not shown in the sketch). A 10- to 30-micron mounting accuracy has been achieved utilizing this method..
Photographic copy Photograph of 1892 drawing by artist H.W. Locket. ...
Photographic copy Photograph of 1892 drawing by artist H.W. Locket. Original Photographer Unknown. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. EARLY DESIGN OF DOUBLE TRACK RAILROAD BRIDGE OVER MISSISSIPPI RIVER ABOVE THE CITY OF NEW ORLEANS, LA, U.S.A. TO BE BUILT BY SOUTHERN BRIDGE AND RAILWAY COMPANY. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa 1934 black and white aerial photograph. ...
Photographic copy of circa 1934 black and white aerial photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. CIRCA 1934 AERIAL PHOTOGRAPH TAKEN FROM EAST BANK LOOKING SOUTH TOWARD WEST BANK SHOWING COMPLETED BRIDGE PIERS AND DECK TRUSS BETWEEN PIERS C, B, AND V. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of undated 12 x 36 pen and ink ...
Photographic copy of undated 12 x 36 pen and ink drawing by Modjeski, Masters and Chase, Bridge Engineers. Illustrator Unknown. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. PEN AND INK DRAWING OF FINAL PROPOSAL OF BRIDGE OVER THE MISSISSIPPI RIVER, NEW ORLEANS, LA. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of black and white, 4 x 8 photograph. ...
Photographic copy of black and white, 4 x 8 photograph. Located loose in oversized box at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. EARLY PHOTOGRAPH OF BRIDGE TAKEN AT NIGHT FROM WEST BANK APPROACH LOOKING NORTH TOWARD EAST BANK SHOWING ILLUMINATED LIGHT FIXTURES AT EDGE OF ROADWAY. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of 10 x 14, black and white photograph ...
Photographic copy of 10 x 14, black and white photograph mounted on card stock. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. PHOTOGRAPH OF WEST BOUND DESCENDING ROADWAY LOOKING SOUTHEAST TOWARD THE WEST BANK. BRIDGE ROADWAY NEAR COMPLETION, LIGHT POLES IN PLACE, NO FIXTURES. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa 1934, 10 x 15, black and ...
Photographic copy of circa 1934, 10 x 15, black and white aerial photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. AERIAL PHOTOGRAPH OF BRIDGE UNDER CONSTRUCTION FROM WEST BANK LOOKING NORTH TOWARD EAST BANK DOWN RIVER SHOWING OVERALL VIEW OF BRIDGE PIER CONSTRUCTION. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa, 1934 black and white photograph. Loose ...
Photographic copy of circa, 1934 black and white photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. VIEW FROM EAST BANK LOOKING SOUTH TOWARD WEST BANK AT BRIDGE UNDER CONSTRUCTION SHOWING COMPLETED THROUGH TRUSS SPAN BETWEEN PIER III AND IV AND THE UNCOMPLETED DECK TRUSS SPAN BETWEEN PIER IV AND V. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of early 20 x 33, black and white ...
Photographic copy of early 20 x 33, black and white photograph. Located loose in oversized box at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. EARLY PHOTOGRAPH OF BRIDGE TAKEN FROM DOWN RIVER NEAR EAST BANK LOOKING SOUTHWEST UP RIVER TOWARD WEST BANK SHOWING STEAM LOCOMOTIVE TRAIN CROSSING BRIDGE. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa 1933, 10 x 15 black and ...
Photographic copy of circa 1933, 10 x 15 black and white aerial photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. AERIAL PHOTOGRAPH SHOWING CONSTRUCTION OF PIER NO.S V AND B LOOKING AT WEST BANK APPROACH UNDER CONSTRUCTION. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of circa 1933, 10 x 15 black and ...
Photographic copy of circa 1933, 10 x 15 black and white aerial photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. AERIAL PHOTOGRAPH SHOWING CONSTRUCTION OF PIER NO.S III, 1V, V, AND B WITH WEST BANK APPROACH AT LOWER EDGE. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
1992-03-01
otherwise managed. Regulated under the Resource Conservation and Recovery Act (RCRA). Heavy metals . A metal (e.g., lead, mercury, cadmkum, and chromium) of...Pb). A heavy metal used in many Industries, which can accumulate in the body and cause a variety of negative effects. One of the six pollutants for...required for the EIS. 7.16 mom The EI5 should address roadbed Impacts caused In transporting heavy oversized miltary equIpme. (30-2) m The issue of
Photographic copy of circa 1935, black and white, 10 x ...
Photographic copy of circa 1935, black and white, 10 x 14 photograph. Loose in Huey P. Long folder in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Photographer, Lionel T. Berryhill, Apple Valley, California. CIRCA 1935 PHOTOGRAPH OF BRIDGE TAKEN FROM WEST BANK LOOKING NORTH AT PIER A NEAR LEVEE. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Photographic copy of 7 x 12 black and white photograph ...
Photographic copy of 7 x 12 black and white photograph of 1927 pencil drawing mounted on card stock by artist Hugh Ferris. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. 1927 PENCIL DRAWING MOUNTED ON CARD STOCK BY ARTIST HUGH FERRIS SHOWING EARLY DESIGN OF PROPOSED MISSISSIPPI RIVER BRIDGE. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Top-down approach for nanophase reconstruction in bulk heterojunction solar cells.
Kong, Jaemin; Hwang, In-Wook; Lee, Kwanghee
2014-09-01
"Top-Down" nanophase reconstruction via a post-additive soaking process is first presented with various BHJ binary composites. By simply rinsing as-cast BHJ films with a solvent mixture containing a few traces of a nanophase-control reagent such as 1,8-diiodooctane, oversized fullerene-rich clusters (>100 nm in dia-meter) in the BHJ film are instataneously disassembled and entirely reorganized into finely intermixed donor/acceptor nanophases (ca. 10 nm) with a 3D compositional homogeneity, without surface segregation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Betatron Application in Mobile and Relocatable Inspection Systems for Freight Transport Control
NASA Astrophysics Data System (ADS)
Chakhlov, S. V.; Kasyanov, S. V.; Kasyanov, V. A.; Osipov, S. P.; Stein, M. M.; Stein, A. M.; Xiaoming, Sun
2016-01-01
Accelerators with energy level up to 4 MeV having high level of penetration ability by steel equivalent are the popular to control oversize cargo transported by road, by railway and by river. Betatron's usage as cyclic induction accelerator has some advantages in comparison with linear accelerators and other sources. Tomsk Polytechnic University has developed many types of betatrons, most of them are being produced by separate affiliated company " Foton ". Article is shown the results of application of the betatrons in inspection custom systems.
2000-02-01
outside oversized heavy tracked vehicle cleaning bay; a utility, equipment, and storage area. The double bays will be sized to support Family Medium...very well delay important airborne combat missions. The facility will be operated during four seasons, with most of the heavy activity accruing in the...protective security a metal clad door on the evidence depository with 24 hour lighting will be provided. 11. REQ: 607 m2 ADQT: NONE SUBSTD: 315 m2 PROJECT
Performance of a Brayton power system with a space type radiator
NASA Technical Reports Server (NTRS)
Nussle, R. C.; Prok, G. M.; Fenn, D. B.
1974-01-01
Test results of an experimental investigation to measure Brayton engine performance while operating at the sink temperatures of a typical low earth orbit are presented. The results indicate that the radiator area was slightly oversized. The steady state and transient responses of the power system to the sink temperatures in orbit were measured. During the orbital operation, the engine did not reach the steady state operation of either sun or shade conditions. The alternator power variation during orbit was + or - 4 percent from its mean value of 9.3 kilowatts.
METHOD FOR PREPARATION OF UO$sub 2$ PARTICLES
Johnson, J.R.; Taylor, A.J.
1959-09-22
A method is described for the preparation of highdensity UO/sub 2/ particles within the size range of 40 to 100 microns. In accordance with the invention UO/sub 2/ particles are autoclaved with an aqueous solution of uranyl ions. The resulting crystals are reduced to UO/sub 2/ and the UO/sub 2/ is heated to at least 1000 deg C to effect densification. The resulting UO/sub 2/ particles are screened, and oversize particles are crushed and screened to recover the particles within the desired size range.
Maeda, Koichi; Kuratani, Toru; Torikai, Kei; Shimamura, Kazuo; Mizote, Isamu; Ichibori, Yasuhiro; Takeda, Yasuharu; Daimon, Takashi; Nakatani, Satoshi; Nanto, Shinsuke; Sawa, Yoshiki
2013-07-01
Even mild paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is associated with increased late mortality. Electrocardiogram-gated multi-slice computed tomography (MSCT) enables detailed aortic annulus assessment. We describe the impact of MSCT for PVL following TAVR. Congruence between the prosthesis and annulus diameters affects PVL; therefore, we calculated the OverSized AortiC Annular ratio (OSACA ratio) and OSACA (transesophageal echocardiography, TEE) ratio as prosthesis diameter/annulus diameter on MSCT or TEE, respectively, and compared their relationship with PVL ≤ trace following TAVR. Of 36 consecutive patients undergoing TAVR (Group A), the occurrence of PVL ≤ trace (33.3%) was significantly related to the OSACA ratio (p = 0.00020). In receiver-operating characteristics analysis, the cutoff value of 1.03 for the OSACA ratio had the highest sum of sensitivity (75.0%) and specificity (91.7%; AUC = 0.87) with significantly higher discriminatory performance for PVL as compared to the OSACA (TEE) ratio (AUC = 0.69, p = 0.028). In nine consecutive patients (Group B) undergoing TAVR based on guidelines formulated from our experience with Group A, PVL ≤ trace was significantly more frequent (88.9%) than that in Group A (p = 0.0060). The OSACA ratio has a significantly higher discriminatory performance for PVL ≤ trace than the OSACA (TEE) ratio, and aortic annular measurement from MSCT is more accurate than that from TEE. © 2013 Wiley Periodicals, Inc.
Inter-Pregnancy Weight Change and the Risk of Recurrent Pregnancy Complications
Wallace, Jacqueline M.; Bhattacharya, Sohinee; Campbell, Doris M.; Horgan, Graham W.
2016-01-01
Women with specific adverse pregnancy outcomes in their first pregnancy may be receptive to inter-pregnancy weight management guidance aimed at preventing these complications reoccurring in subsequent pregnancies. Thus the association between inter-pregnancy weight change and the risk of recurrent pregnancy complications at the second pregnancy was investigated in a retrospective cohort study of 24,520 women with their first-ever and second consecutive deliveries in Aberdeen using logistic regression. Compared with women who were weight stable, weight loss (>2BMI units) between pregnancies was associated with an increased risk of recurrent small for gestational age (SGA) birth and elective Cesarean-section, and was protective against recurrent pre-eclampsia, placental oversize and large for gestational age (LGA) birth. Conversely weight gain (>2BMI units) between pregnancies increased the risk of recurrent gestational hypertension, placental oversize and LGA birth and was protective against recurrent low placental weight and SGA birth. The relationships between weight gain, and placental and birth weight extremes were evident only in women with a healthy weight at first pregnancy (BMI<25units), while that between weight gain and the increased risk of recurrent gestational hypertension was largely independent of first pregnancy BMI. No relationship was detected between inter-pregnancy weight change and the risk of recurrent spontaneous preterm delivery, labour induction, instrumental delivery, emergency Cesarean-section or postpartum hemorrhage. Therefor inter-pregnancy weight change impacts the risk of recurrent hypertensive disorders, SGA and LGA birth and women with a prior history of these specific conditions may benefit from targeted nutritional advice to either lose or gain weight after their first pregnancy. PMID:27145132
Impact of stent mis-sizing and mis-positioning on coronary fluid wall shear and intramural stress
Chen, Henry Y.; Koo, Bon-Kwon; Bhatt, Deepak L.
2013-01-01
Stent deployments with geographical miss (GM) are associated with increased risk of target-vessel revascularization and periprocedural myocardial infarction. The aim of the current study was to investigate the underlying biomechanical mechanisms for adverse events with GM. The hypothesis is that stent deployment with GM [longitudinal GM, or LGM (i.e., stent not centered on the lesion); or radial GM, RGM (i.e., stent oversizing)] results in unfavorable fluid wall shear stress (WSS), WSS gradient (WSSG), oscillatory shear index (OSI), and intramural circumferential wall stress (CWS). Three-dimensional computational models of stents and plaque were created using a computer-assisted design package. The models were then solved with validated finite element and computational fluid dynamic packages. The dynamic process of large deformation stent deployment was modeled to expand the stent to the desired vessel size. Stent deployed with GM resulted in a 45% increase in vessel CWS compared with stents that were centered and fully covered the lesion. A 20% oversized stent resulted in 72% higher CWS than a correct sized stent. The linkages between the struts had much higher stress than the main struts (i.e., 180 MPa vs. 80 MPa). Additionally, LGM and RGM reduced endothelial WSS and increased WSSG and OSI. The simulations suggest that both LGM and RGM adversely reduce WSS but increase WSSG, OSI, and CWS. These findings highlight the potential mechanical mechanism of the higher adverse events and underscore the importance of stent positioning and sizing for improved clinical outcome. PMID:23722708
Riesch, Susan K; Ngui, Emmanuel M; Ehlert, Carey; Miller, M Katie; Cronk, Christine A; Leuthner, Steven; Strehlow, Mary; Hewitt, Jeanne B; Durkin, Maureen S
2013-05-01
The purpose of this methods article was to describe and evaluate outreach and engagement strategies designed to initially build county-wide awareness and support for the National Children's Study (NCS or the study) and subsequently to target the segment communities where recruitment for the study occurred. Selected principles from community outreach, social marketing, and health care system and personal referral formed the foundation for the strategies. The strategies included a celebration event, community advisory board, community needs assessment, building relationships with health care providers and systems, eliciting a network of study supporters, newsletters, appearances at local young family-oriented events (health fairs, parades), presentations to local community leaders, community forums, "branding" with assistance from a women-owned local marketing firm, and mailings including an oversized, second-touch postcard. Six months after study launch, approximately 4,600 study-eligible women were asked in a door-to-door survey if and how they became aware of the study. On average, 40% of eligible women reported being aware of the study. The most frequently cited strategy to cultivate their awareness was study-specific mailings. Awareness of the NCS increased by 7.5% among those receiving a second-touch postcard relative to controls (95% CIs [4.9, 10.7] z = 5.347, p < 0.0000, d = 0.16). Community outreach and engagement strategies, in particular the oversized postcard as a second-touch effort, may be used effectively by researchers for participant recruitment and by public health nurses for delivery of important population-focused messages. © 2013 Wiley Periodicals, Inc.
Riesch, Susan K.; Ngui, Emmanuel; Ehlert, Carey; Miller, M. Katie; Cronk, Christine A.; Leuthner, Steven; Strehlow, Mary; Hewitt, Jeanne; Durkin, Maureen S.
2014-01-01
The purpose of this methods paper is to describe and evaluate outreach and engagement strategies designed to initially build county-wide awareness and support for the National Children’s Study (NCS or the study) and subsequently to target the segment communities where recruitment for the study occurred. Selected principles from community outreach, social marketing, and healthcare system and personal referral formed the foundation for the strategies. The strategies included a celebration event, community advisory board, community needs assessment, building relationships with healthcare providers and systems, eliciting a network of study supporters, newsletters, appearances at local young family-oriented events (health fairs, parades), presentations to local community leaders, community forums, “branding” with assistance from a women-owned local marketing firm, and mailings including an oversized, second-touch postcard. Six months after study launch, approximately 4600 study-eligible women were asked in a door-to-door survey if and how they became aware of the study. On average, 40% of eligible women reported being aware of the study. The most frequently cited strategy to cultivate their awareness was study-specific mailings. Awareness of the NCS increased by 7.5% among those receiving a second-touch postcard relative to controls 95% CIs [4.9, 10.7] z = 5.347, p < 0.0000, d = 0.16. Community outreach and engagement strategies, in particular the oversized postcard as a second-touch effort, may be used effectively by researchers for participant recruitment and by public health nurses for delivery of important population-focused messages. PMID:23586770
Variable Frequency Operations of an Offshore Wind Power Plant with HVDC-VSC: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gevorgian, V.; Singh, M.; Muljadi, E.
2011-12-01
In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated. Based on DOE study, wind power generation may reach 330 GW by 2030 at the level of penetration of 20% of the total energy production. From this amount of wind power, 54 GW of wind power will be generated at offshore wind power plants. The deployment of offshore wind power plants requires power transmission from the plant to the load center inland. Since this power transmissionmore » requires submarine cable, there is a need to use High-Voltage Direct Current (HVDC) transmission. Otherwise, if the power is transmitted via alternating current, the reactive power generated by the cable capacitance may cause an excessive over voltage in the middle of the transmission distance which requires unnecessary oversized cable voltage breakdown capability. The use of HVDC is usually required for transmission distance longer than 50 kilometers of submarine cables to be economical. The use of HVDC brings another advantage; it is capable of operating at variable frequency. The inland substation will be operated to 60 Hz synched with the grid, the offshore substation can be operated at variable frequency, thus allowing the wind power plant to be operated at constant Volt/Hz. In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated.« less
Low vibration microminiature split Stirling cryogenic cooler for infrared aerospace applications
NASA Astrophysics Data System (ADS)
Veprik, A.; Zechtzer, S.; Pundak, N.; Kirkconnel, C.; Freeman, J.; Riabzev, S.
2011-06-01
The operation of the thermo-mechanical unit of a cryogenic cooler may originate a resonant excitation of the spacecraft frame, optical bench or components of the optical train. This may result in degraded functionality of the inherently vibration sensitive space-borne infrared imager directly associated with the cooler or neighboring instrumentation typically requiring a quiet micro-g environment. The best practice for controlling cooler induced vibration relies on the principle of active momentum cancellation. In particular, the pressure wave generator typically contains two oppositely actuated piston compressors, while the single piston expander is counterbalanced by an auxiliary active counter-balancer. Active vibration cancellation is supervised by a dedicated DSP feed-forward controller, where the error signals are delivered by the vibration sensors (accelerometers or load cells). This can result in oversized, overweight and overpriced cryogenic coolers with degraded electromechanical performance and impaired reliability. The authors are advocating a reliable, compact, cost and power saving approach capitalizing on the combined application of a passive tuned dynamic absorber and a low frequency vibration isolator. This concept appears to be especially suitable for low budget missions involving mini and micro satellites, where price, size, weight and power consumption are of concern. The authors reveal the results of theoretical study and experimentation on the attainable performance using a fullscale technology demonstrator relying on a Ricor model K527 tactical split Stirling cryogenic cooler. The theoretical predictions are in fair agreement with the experimental data. From experimentation, the residual vibration export is quite suitable for demanding wide range of aerospace applications. The authors give practical recommendations on heatsinking and further maximizing performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-07-04
A 1-MW geothermal wellhead power plant incorporating a Lysholm or helical screw expander (HSE) was field tested between 1980 and 1983 by Mexico, Italy, and New Zealand with technical assistance from the United States. The objectives were to provide data on the reliability and performance of the HSE and to assess the costs and benefits of its use. The range of conditions under which the HSE was tested included loads up to 933 kW, mass flowrates of 14,600 to 395, 000 lbs/hr, inlet pressures of 64 to 220 psia, inlet qualities of 0 to 100%, exhaust pressures of 3.1 tomore » 40 psia, total dissolved solids up to 310,000 ppM, and noncondensible gases up to 38% of the vapor mass flow. Typical machine efficiencies of 40 to 50% were calculated. For most operations efficiency increased approximately logarithmically with shaft power, while inlet quality and rotor speed had only small effects. The HSE was designed with oversized internal clearances in the expectation that adherent scale would form during operation. Improvements in machine efficiency of 3.5 to 4 percentage points were observed over some test periods with some scale deposition. A comparison with a 1-MW back-pressure turbine showed that the HSE can compete favorably under certain conditions. The HSE was found to be a rugged energy conversion machine for geothermal applications, but some subsystems were found to require further development. 7 refs., 28 figs., 5 tabs.« less
Photographic copy of circa 1934, 10 x 15, black and ...
Photographic copy of circa 1934, 10 x 15, black and white aerial photograph. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. AERIAL PHOTOGRAPH OF BRIDGE UNDER CONSTRUCTION LOOKING SOUTH FROM EAST BANK TOWARD WEST BANK SHOWING COMPLETED STEEL RAIL SECTION AND PART OF BRIDGE DECK TRUSS UNDER CONSTRUCTION. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
Transportation of Large Wind Components: A Review of Existing Geospatial Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mooney, Meghan; Maclaurin, Galen
2016-09-01
This report features the geospatial data component of a larger project evaluating logistical and infrastructure requirements for transporting oversized and overweight (OSOW) wind components. The goal of the larger project was to assess the status and opportunities for improving the infrastructure and regulatory practices necessary to transport wind turbine towers, blades, and nacelles from current and potential manufacturing facilities to end-use markets. The purpose of this report is to summarize existing geospatial data on wind component transportation infrastructure and to provide a data gap analysis, identifying areas for further analysis and data collection.
NASA Technical Reports Server (NTRS)
Cukor, P. M.; Chapman, R. A.
1978-01-01
The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.
Method for forming precision clockplate with pivot pins
Wild, Ronald L [Albuquerque, NM
2010-06-01
Methods are disclosed for producing a precision clockplate with rotational bearing surfaces (e.g. pivot pins). The methods comprise providing an electrically conductive blank, conventionally machining oversize features comprising bearing surfaces into the blank, optionally machining of a relief on non-bearing surfaces, providing wire accesses adjacent to bearing surfaces, threading the wire of an electrical discharge machine through the accesses and finishing the bearing surfaces by wire electrical discharge machining. The methods have been shown to produce bearing surfaces of comparable dimension and tolerances as those produced by micro-machining methods such as LIGA, at reduced cost and complexity.
Infolding of fenestrated endovascular stent graft.
Zelt, Jason G E; Jetty, Prasad; Hadziomerovic, Adnan; Nagpal, Sudhir
2017-09-01
We report a case of infolding of a fenestrated stent graft involving the visceral vessel segment after a juxtarenal abdominal aorta aneurysm repair. The patient remains free of any significant endoleak, and the aortic sac has shown regression. The patient remains asymptomatic, with no abdominal pain, with normal renal function, and without ischemic limb complications. We hypothesize that significant graft oversizing (20%-30%) with asymmetric engineering of the diameter-reducing ties may have contributed to the infolding. Because of the patient's asymptomatic nature and general medical comorbidities, further intervention was deemed inappropriate as the aneurysmal sac is regressing despite the infolding.
NASA Astrophysics Data System (ADS)
Zhang, Weiping; Shen, Zhenyu; Tang, Rui; Jin, Suoxue; Song, Yaoxiang; Long, Yunxiang; Wei, Yaxia; Zhou, Xiong; Chen, Cheng; Guo, Liping
2018-07-01
An effective method to improve the irradiation resistance of austenitic stainless steels is adding oversized solutes into steels. In this work, the irradiation resistances of two type of modified 310S steels, in one of which Zr was added and in another Nb, Ta, and W were added, were investigated by proton irradiations at 563 K. Irradiation induced vacancy-type defects was characterized with positron annihilation spectroscopy (PAS), while dislocation loops and bubbles whose size are greater than 1 nm are characterized with transmission electron microscopy (TEM). It is found that the relative S parameter ΔS/S extracted from PAS is more effective than S parameter in evaluating the quantity of vacancy-type defects. It was revealed from ΔS/S that more vacancy-type defects produced in (Nb, Ta, W)-added steels than that in Zr-added steels, and this trend became more obvious with the dose increasing. S-W curves reveal that proton irradiation induced two kinds of vacancy-type defects, i.e. vacancy clusters and proton-vacancy clusters. TEM observation shows that the density of small bubbles induced by proton in (Nb, Ta, W)-added steels is much higher than that in Zr-added steels. Both 1/3 <1 1 1> and 1/2 <1 1 0> dislocation loops were observed with TEM in all of the specimens. The mean size and number density of dislocation loops in (Nb, Ta, W)-added steels are slightly larger than that in Zr-added steels, and increased with increasing irradiation dose. Both PAS and TEM observations shows that irradiation damage in Zr-added steels is less serious than that (Nb, Ta, W)-added steels, and the possible mechanisms are discussed through the enhancement of point defect recombination by oversized solute atoms.
Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size.
Seo, Jeong-Hwa; Bae, Jinyoung; Paik, Hyesun; Koo, Chang-Hoon; Bahk, Jae-Hyon
2018-04-01
The bronchial diameter measured on computed tomography (CT) can be used to guide double-lumen tube (DLT) sizes objectively. The bronchus is known to be measured most accurately in the so-called bronchial CT window. The authors investigated whether using the bronchial window results in the selection of more appropriately sized DLTs than using the other windows. CT image analysis and prospective randomized study. Tertiary hospital. Adults receiving left-sided DLTs. The authors simulated selection of DLT sizes based on the left bronchial diameters measured in the lung (width 1,500 Hounsfield unit [HU] and level -700 HU), bronchial (1,000 HU and -450 HU), and mediastinal (400 HU and 25 HU) CT windows. Furthermore, patients were randomly assigned to undergo imaging with either the bronchial or mediastinal window to guide DLT sizes. Using the underwater seal technique, the authors assessed whether the DLT was appropriately sized, undersized, or oversized for the patient. On 130 CT images, the bronchial diameter (9.9 ± 1.2 mm v 10.5 ± 1.3 mm v 11.7 ± 1.3 mm) and the selected DLT size were different in the lung, bronchial, and mediastinal windows, respectively (p < 0.001). In 13 patients (17%), the bronchial diameter measured in the lung window suggested too small DLTs (28 Fr) for adults. In the prospective study, oversized tubes were chosen less frequently in the bronchial window than in the mediastinal window (6/110 v 23/111; risk ratio 0.38; 95% CI 0.19-0.79; p = 0.003). No tubes were undersized after measurements in these two windows. The bronchial measurement in the bronchial window guided more appropriately sized DLTs compared with the lung or mediastinal windows. Copyright © 2017 Elsevier Inc. All rights reserved.
Marini, Davide; Castagno, Matteo; Millesimo, Michele; Ferroni, Francesca; Ferraro, Gaetana; Pace Napoleone, Carlo; Agnoletti, Gabriella
2017-10-01
Data regarding long-term outcome after percutaneous closure of left superior caval vein draining into the left atrium are lacking. The aim of the present study was to report the long-term follow-up by using contrast-enhanced CT. In all, three patients underwent percutaneous closure of left superior caval vein draining into the left atrium between 2005 and 2015. All of them were evaluated clinically and underwent contrast-enhanced CT. In one patient, the Amplatzer® Septal Occluder was used. In two patients, the Amplatzer® Vascular Plug type-1 was preferred: the device size/LSVC diameter ratio was 1.7 in the child and 1.2 in the adult. There were no early-onset or long-term onset complications. CT was performed 1, 2, and 10 years after the procedure, respectively. Complete occlusion of the vessel was documented in all. After 10 years since the procedure, CT revealed a persistent trivial residual shunt through the accessory hemiazygos vein in one patient, in whom the device was implanted above its drainage into the left superior caval vein. When an Amplatzer® Vascular Plug type-1 is oversized compared with the venous vessel diameter, it immediately assumes a dog-bone shape that disappears early to regain its shape memory and nominal size. Percutaneous occlusion of left superior caval vein draining into the left atrium has excellent early and long-term outcomes. The optimal implantation of the device is below the drainage of the accessory hemiazygos vein, when present. The device might be oversized compared with the left superior caval vein diameter according to the age of the patient.
Sultan, Sherif; Kavanagh, Edel P; Hynes, Niamh; Diethrich, Edward B
2016-02-01
This study outlines the use of non-aneurysmal porcine animal models to study device functionality and biological response of the Multilayer Flow Modulator (MFM) (Cardiatis, Isnes, Belgium), with an emphasis on preclinical device functionality and biological response characteristics in an otherwise healthy aorta. Twelve animals were implanted with the study device in the abdominal aorta, in 6 animals for 1 month and 6 animals for 6 months. Upon completion of the study period, each animal underwent a necropsy to examine how the implanted device had affected the artery and surrounding tissue. Neointima and stenosis formation were recorded via morphometry, and endothelialization via histopathological analysis. The MFM devices were delivered to their respective implantation sites without difficulty. Six of the implanted stents were oversized with percentages ranging from 2.6% to 18.8%. Statistical analysis was carried out and showed no significance between the regular sized stent group and oversized stent group for neointimal area (P=0.17), neointimal thickness (P=0.17), and percentage area stenosis (P=0.65). Histopathological findings showed in most areas flattened endothelium like cells lined the luminal surface of the neointima. Scanning electron microscopy also showed the devices were well tolerated, inciting only a minimal neointimal covering and little fibrin or platelet deposition. Neointimal thickness of 239.7±55.6 μm and 318.3±130.4 μm, and percentage area stenosis of 9.6±2.6% and 12.6±5% were recorded at 1 and 6 months respectively. No statistical differences were found between these results. The MFM devices were delivered to their respective implantation sites without difficulty and incited little neointimal and stenosis formation in the aorta, affirming its functionality and biocompatibility.
NASA Astrophysics Data System (ADS)
Simonetto, A.; Platania, P.; Garavaglia, S.; Gittini, G.; Granucci, G.; Pallotta, F.
2018-02-01
Plasma position reflectometry for ITER requires interfaces between in-vessel and ex-vessel waveguides. An ultra broadband interface (15-75 GHz) was designed between moderately oversized rectangular waveguide (20 × 12 mm), operated in TE01 (i.e., tall waveguide mode), and circular corrugated waveguide, with 88.9-mm internal diameter, propagating HE11. The interface was designed both as a sequence of waveguide components and as a quasi-optical confocal telescope. The design and the simulated performance are described for both concepts. The latter one requires more space but has better performance, and shall be prototyped.
Unified criteria for multipartite quantum nonlocality
NASA Astrophysics Data System (ADS)
Cavalcanti, E. G.; He, Q. Y.; Reid, M. D.; Wiseman, H. M.
2011-09-01
Wiseman and co-workers [H. M. Wiseman, S. J. Jones, and A. C. Doherty, Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.98.140402 98, 140402, (2007)] proposed a distinction among the nonlocality classes of Bell's nonlocality, Einstein-Podolsky-Rosen (EPR) paradox or steering, and entanglement based on whether or not an overseer trusts each party in a bipartite scenario where they are asked to demonstrate entanglement. Here we extend that concept to the multipartite case and derive inequalities that progressively test for those classes of nonlocality, with different thresholds for each level. This framework includes the three classes of nonlocality above in special cases and introduces a family of others.
Photographic copy of circa 1935, black and white, 10 x ...
Photographic copy of circa 1935, black and white, 10 x 14 photograph. Located loose in oversized box at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. Original Photographer unknown. Obtained from Rochester, New York, Mrs. (Not Legible) Hagan Bentz, National Librarian Home, Washington, D.C., March 1967. CIRCA 1935 PHOTOGRAPH OF THE FIRST PASSENGER TRAIN TO CROSS THE BRIDGE FROM WEST BANK APPROACH LOOKING NORTH TOWARD EAST BANK. - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA
An operations management system for the Space Station
NASA Astrophysics Data System (ADS)
Savage, Terry R.
A description is provided of an Operations Management System (OMS) for the planned NASA Space Station. The OMS would be distributed both in space and on the ground, and provide a transparent interface to the communications and data processing facilities of the Space Station Program. The allocation of OMS responsibilities has, in the most current Space Station design, been fragmented among the Communications and Tracking Subsystem (CTS), the Data Management System (DMS), and a redefined OMS. In this current view, OMS is less of a participant in the real-time processing, and more an overseer of the health and management of the Space Station operations.
The Galvanic Corrosion of Graphite Epoxy Composite Materials Coupled with Alloys
1975-12-01
Approved for public release; distribution unlimited. 17 DISTR:3UTION STATEMENT (of the absatract entered in Block 10, If different from Report) IS...SUPPLEMENTARY NIOTES 1x6Voved for p ,11c elease; IA14 AFR j,90- 17 .~y C. X Capta~4 USAF Dre c tor’ of Xn f’orma Cion 19. K~EY W OS (Continiue an r.overse...acceptability by particular alloy is as follows: Acceptable-Ti-6A1-4V, Ti-6A!-2Sn-4 Zr-2o, Rene 41, Inconel X, Inconel, AFC-77, PH 17 -7, SS-304, Be-Cu, SS
Monitoring of live and woody elements
NASA Astrophysics Data System (ADS)
Guastini, Enrico; Preti, Federico
2013-04-01
This study deals with surveys operated on crib walls in Casentino and Versilia (Tuscany), where Salix alba cuttings did not develop as expected from literature data. After more then 10 years since realization and and an initial very high survival rate, a few plants are yet alive among those put in place and the root strengthening is localized in the first 0.30 m just below the structure front face, while at further depth the detected root area ratio (R.A.R.) does not determine a noticeable increase in soil cohesion (Guastini et al., 2012). Mortality curve in willow cuttings is comparable with growing curve in Alnus nigra plants born in front of the structure, due to shading as failing cause. Assessing quantitatively the residual strength of the timber elements and estimating their possible duration allow comparison with the time needed for a complete stabilisation of the para-natural succession. The two spans of time must be almost similar to avoid unexpected collapse of the frame or unacceptable costs for oversized structures. Since the realization of a new live crib-wall in Casentino we sampled Alnus and Salix cuttings to compare rooting, survivability and evolution in randomized block design. Tests with Resistograph carried out on timber elements gives a good relationship between test results and density; through the non-destructive test it is possible to differentiate portions of wood with a noticeable residual strength from the decayed parts without any more load bearing capacity. MOR value (flexural strength) of timber elements has been estimated on the basis of the effective section verified by the Resistograph (Guastini et al., 2012), and then confirmed through rupture in bending of the same elements (Wood Technology DEISTAF lab), by proving the non-destructive test utility.
Concept Development of a Mach 1.6 High-Speed Civil Transport
NASA Technical Reports Server (NTRS)
Shields, Elwood W.; Fenbert, James W.; Ozoroski, Lori P.; Geiselhart, Karl A.
1999-01-01
A high-speed civil transport configuration with a Mach number of 1.6 was developed as part of the NASA High-Speed Research Program to serve as a baseline for assessing advanced technologies required for an aircraft with a service entry date of 2005. This configuration offered more favorable solutions to environmental concerns than configurations with higher Mach numbers. The Mach 1.6 configuration was designed for a 6500 n.mi. mission with a 250-passenger payload. The baseline configuration has a wing area of 8732 square feet a takeoff gross weight of 591570 lb, and four 41000-lb advanced turbine bypass engines defined by NASA. These engines have axisymmetric mixer-ejector nozzles that are assumed to yield 20 dB of noise suppression during takeoff, which is assumed to satisfy, the FAR Stage III noise requirements. Any substantial reduction in this assumed level of suppression would require oversizing the engines to meet community noise regulations and would severly impact the gross weight of the aircraft at takeoff. These engines yield a ratio of takeoff thrust to weight of 0.277 and a takeoff wing loading of 67.8 lb/square feet that results in a rotation speed of 169 knots. The approach velocity of the sized configuration at the end of the mission is 131 knots. The baseline configuration was resized with an engine having a projected life of 9000 hr for hot rotating parts and 18000 hr for the rest of the engine, as required for commercial use on an aircraft with a service entry date of 2005. Results show an increase in vehicle takeoff gross weight of approximately 58700 lb. This report presents the details of the configuration development, mass properties, aerodynamic design, propulsion system and integration, mission performance, and sizing.
Optimizing abdominal CT dose and image quality with respect to x-ray tube voltage
NASA Astrophysics Data System (ADS)
Huda, Walter; Ogden, Kent M.
2004-05-01
The objective of this study was to identify the x-ray tube voltage that results in optimum performance for abdominal CT imaging for a range of imaging tasks and patient sizes. Theoretical calculations were performed of the contrast to noise ratio (CNR) for disk shaped lesions of muscle, fat, bone and iodine embedded in a uniform water background. Lesion contrast was the mean Hounsfield Unit value at the effective photon energy, and image noise was determined from the total radiation intensity incident on the CT x-ray detector. Patient size ranging from young infants (10 kg) to oversized adults (120 kg), with CNR values obtained for x-ray tube voltages ranging from 80 to 140 kV. Patients of varying sizes were modeled as an equivalent cylinder of water, and the mean section dose (D) was determined for each selected x-ray tube kV value at a constant mAs. For each patient size and lesion type, we identified an optimal kV as the x-ray tube voltage that yields a maximum value of the figure of merit (CNR2/D). Increasing the x-ray tube voltage from 80 to 140 kV reduced lesion contrast by 11% for muscle, 21% for fat, 35% for bone and 52% for iodine, and these reductions were approximately independent of patient size. Increasing the x-ray tube voltage from 80 to 140 kV increased a muscle lesion CNR relative to a uniform water background by a factor of 2.6, with similar trends observed for fat (2.3), bone (1.9) and iodine (1.4). The improvement in lesion CNR with increasing x-ray tube voltage was highest for the largest sized patients. Increasing the x-ray tube voltage from 80 to 140 kV increased the patient dose by a factor of between 5.0 and 6.2 depending on the patient size. For small sized patients (10 and 30 kg) and muscle lesions, best performance is obtained at 80 kV; however, for adults (70 kg) and oversized adults (120 kg), the best performance would be obtained at 140 kV. Imaging fat lesions was best performed at 80 kV for all patients except for oversized adults, where 140 kV offers the best imaging performance. For high Z lesions of bone and iodine, imaging performance generally degrades with increasing kV for all patient sizes, with the degree of degradation largest for the smallest patients. We conclude that 80 kV is optimal with respect to radiation dose in abdominal CT for all pediatric patients. For adults, 80 kV is the x-ray voltage of choice for high Z lesions, whereas 140 kV would generally be the voltage of choice of lesions that have an atomic number similar to that of water.
Sedimentation and the Economics of Selecting an Optimum Reservoir Size
NASA Astrophysics Data System (ADS)
Miltz, David; White, David C.
1987-08-01
This paper attempts to develop an easily reproducible methodology for the economic selection of an optimal reservoir size given an annual sedimentation rate. The optimal capacity is that at which the marginal cost of constructing additional storage capacity is equal to the dredging costs avoided by having that additional capacity available to store sediment. The cost implications of misestimating dredging costs, construction costs, and sediment delivery rates are investigated. In general, it is shown that oversizing is a rational response to uncertainty in the estimation of parameters. The sensitivity of the results to alternative discount rates is also discussed. The theoretical discussion is illustrated with a case study drawn from Highland Silver Lake in southwestern Illinois.
Method for making a bio-compatible scaffold
Cesarano, III, Joseph; Stuecker, John N [Albuquerque, NM; Dellinger, Jennifer G [Champaigne, IL; Jamison, Russell D [Urbana, IL
2006-01-31
A method for forming a three-dimensional, biocompatible, porous scaffold structure using a solid freeform fabrication technique (referred to herein as robocasting) that can be used as a medical implant into a living organism, such as a human or other mammal. Imaging technology and analysis is first used to determine the three-dimensional design required for the medical implant, such as a bone implant or graft, fashioned as a three-dimensional, biocompatible scaffold structure. The robocasting technique is used to either directly produce the three-dimensional, porous scaffold structure or to produce an over-sized three-dimensional, porous scaffold lattice which can be machined to produce the designed three-dimensional, porous scaffold structure for implantation.
A Method for Decentralised Optimisation in Networks
NASA Astrophysics Data System (ADS)
Saramäki, Jari
2005-06-01
We outline a method for distributed Monte Carlo optimisation of computational problems in networks of agents, such as peer-to-peer networks of computers. The optimisation and messaging procedures are inspired by gossip protocols and epidemic data dissemination, and are decentralised, i.e. no central overseer is required. In the outlined method, each agent follows simple local rules and seeks for better solutions to the optimisation problem by Monte Carlo trials, as well as by querying other agents in its local neighbourhood. With proper network topology, good solutions spread rapidly through the network for further improvement. Furthermore, the system retains its functionality even in realistic settings where agents are randomly switched on and off.
Optical Alignment and Diffraction Analysis for AIRES: An Airborne Infrared Echelle Spectrometer
NASA Technical Reports Server (NTRS)
Haas, Michael R.; Fonda, Mark (Technical Monitor)
2002-01-01
The optical design is presented for a long-slit grating spectrometer known as AIRES (Airborne InfraRed Echelle Spectrometer). The instrument employs two gratings in series: a small order sorter and a large steeply blazed echelle. The optical path includes four pupil and four field stops, including two narrow slits. A detailed diffraction analysis is performed using GLAD by Applied Optics Research to evaluate critical trade-offs between optical throughput, spectral resolution, and system weight and volume. The effects of slit width, slit length, oversizing the second slit relative to the first, on- vs off-axis throughput, and clipping at the pupil stops and other optical elements are discussed.
Impact of Installation Faults on Heat Pump Performance
Hourahan, Glenn; Baxter, Van D.
2015-01-01
Numerous studies and surveys indicate that typically-installed HVAC equipment operate inefficiently and waste considerable energy due to varied installation errors (faults) such as improper refrigerant charge, incorrect airflow, oversized equipment, and leaky ducts. This article summarizes the results of a large United States (U.S.) experimental/analytical study (U.S. contribution to IEA HPP Annex 36) of the impact that different faults have on the performance of an air-source heat pump (ASHP) in a typical U.S. single-family house. It combines building effects, equipment effects, and climate effects in an evaluation of the faults impact on seasonal energy consumption through simulations of the house/ASHPmore » pump system.« less
Protective interior wall and attach8ing means for a fusion reactor vacuum vessel
Phelps, Richard D.; Upham, Gerald A.; Anderson, Paul M.
1988-01-01
An array of connected plates mounted on the inside wall of the vacuum vessel of a magnetic confinement reactor in order to provide a protective surface for energy deposition inside the vessel. All fasteners are concealed and protected beneath the plates, while the plates themselves share common mounting points. The entire array is installed with torqued nuts on threaded studs; provision also exists for thermal expansion by mounting each plate with two of its four mounts captured in an oversize grooved spool. A spool-washer mounting hardware allows one edge of a protective plate to be torqued while the other side remains loose, by simply inverting the spool-washer hardware.
Shibayama, Kentaro; Mihara, Hirotsugu; Jilaihawi, Hasan; Berdejo, Javier; Harada, Kenji; Itabashi, Yuji; Siegel, Robert; Makkar, Raj R; Shiota, Takahiro
2016-02-01
This study of 3-dimensional (3D) transesophageal echocardiography (TEE) aimed to demonstrate features associated with transvalvular aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) and to confirm the fact that a gap between the native aortic annulus and prosthesis is associated with paravalvular AR. The mechanism of AR after TAVR, particularly that of transvalvular AR, has not been evaluated adequately. All patients with severe aortic stenosis who underwent TAVR with the Sapien device (Edwards Lifesciences, Irvine, California) had 3D TEE of the pre-procedural native aortic annulus and the post-procedural prosthetic valve. In the 201 patients studied, the total AR was mild in 67 patients (33%), moderate in 21 patients (10%), and severe in no patients. There were 20 patients with transvalvular AR and 82 patients with paravalvular AR. Fourteen patients had both transvalvular and paravalvular AR. Patients with transvalvular AR had larger prosthetic expansion (p <0.05), a more elliptical prosthetic shape at the prosthetic commissure level (p <0.01) and more anti-anatomical position (p <0.001), which was defined as malposition of the prosthetic commissures in relation to the native commissures, than the patients without transvalvular AR. Age (odds ratio [OR]: 1.05; 95% confidence interval [CI]: 1.01 to 1.09; p < 0.05) and effective area oversizing (OR: 0.97; 95% CI: 0.93 to 0.99, p <0.05) were associated with mild or greater paravalvular AR. 3D TEE successfully demonstrated the features associated with transvalvular AR, such as large prosthetic expansion, elliptical prosthetic shape, and anti-anatomical position of prosthesis. Additionally, effective area oversizing was associated with paravalvular AR. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J
2013-02-01
To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio< 2.5. At 12 months, Rutherford category and ankle-brachial index (ABI) were significantly improved (mean category improvement, 2.4; ABI increased from 0.6±0.2 to 0.9±0.19; P<.0001). Primary and secondary patency rates were 73% and 92%. The primary patency for devices oversized<20% at the proximal landing zone was 88%, whereas the primary patency for devices oversized by>20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.
Inci, Ilhan; Irani, Sarosh; Kestenholz, Peter; Benden, Christian; Boehler, Annette; Weder, Walter
2011-01-01
The limited number of available grafts is one of the major obstacles of lung transplantation. Size-reduced lung transplantation allows the use of oversized grafts for small recipients. Optimal lung size matching is vital to achieve best functional outcome and avoid potential problems when using oversized grafts. We hypothesise that donor-predicted postoperative forced expiratory volume in 1s (ppoFEV1) correlates with the recipient best FEV1 after size-reduced lung transplant, being useful for the estimation of function outcome. All patients undergoing size-reduced or standard bilateral lung transplantation were included (1992-2007). Donor ppoFEV1 was calculated and corrected with respect to size reduction and correlated with recipient measured best FEV1 post-transplant. In addition, pre- and postoperative clinical data including surgical complications and outcome of all size-reduced lung transplant recipients were compared with standard lung transplant recipients. A total of 61 size-reduced lung transplant recipients (lobar transplants, n=20; anatomic or non-anatomic resection, n=41) were included and compared to 145 standard transplants. The mean donor-recipient height difference was statistically significant between the two groups (p=0.0001). The mean donor ppoFEV1 was comparable with recipient best FEV1 (2.7±0.6 vs 2.6±0.7 l). There was a statistically significant correlation between donor ppoFEV1 and recipient best FEV1 (p=0.01, r=0.688). The 30-day mortality rate and 3-month, 1- and 5-year survival rates were comparable between the two groups. In size-reduced lung transplantation, postoperative recipient best FEV1 could be predicted from donor-calculated and corrected FEV1 with respect to its size reduction. Compared to standard lung transplantation, equivalent morbidity, mortality and functional results could be obtained after size-reduced lung transplantation. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Corbett, Timothy J; Callanan, Anthony; O'Donnell, Michael R; McGloughlin, Tim M
2010-02-01
To develop an improved methodology for investigating the parameters influencing stent-graft migration, with particular focus on the limitations of existing methods. A physiological silicone rubber abdominal aortic aneurysm (AAA) model for fixation studies was manufactured based on an idealized AAA geometry: the model had a 24-mm neck, a 50-mm aneurysm, 12-mm-diameter legs, a 60 degrees bifurcation angle, and 2-mm-thick walls. The models were authenticated in neck fixation experiments. The displacement force required to migrate stent-grafts in physiological pulsatile flow was tested dynamically in water at 37 degrees C. A commercially available longitudinally rigid stent-graft (AneuRx) and a homemade device with little longitudinal rigidity were studied in a number of different configurations to investigate the effect of neck fixation length and systolic pressure on displacement force. The AneuRx (6.95+/-0.49 to 8.52+/-0.5 N) performed significantly better than the homemade device (2.57+/-0.11 to 4.62+/-0.25 N) in pulsatile flow. The opposite was true in the neck fixation tests because the longitudinal stiffness of the AneuRx was not accounted for. Increasing pressure or decreasing fixation length compromised the fixation of the homemade device. This relationship was not as clear for the AneuRx because decreasing proximal fixation resulted in an increase in iliac fixation, which could assist fixation in this device. Assessing the migration resistance of stent-grafts based solely on proximal fixation discriminates against devices that are longitudinally stiff. Current in vivo models may give inaccurate displacement forces due to the high degree of oversizing in these studies. A novel in vitro approach, accounting for longitudinal rigidity and realistic graft oversizing, was developed to determine the resistance of aortic stent-grafts to migration in the period immediately after device implantation.
Lietz, K; John, R; Burke, E A; Ankersmit, J H; McCue, J D; Naka, Y; Oz, M C; Mancini, D M; Edwards, N M
2001-07-27
Extremes in body weight are a relative contraindication to cardiac transplantation. We retrospectively reviewed 474 consecutive adult patients (377 male, 97 female, mean age 50.3+/-12.2 years), who received 444 primary and 30 heart retransplants between January of 1992 and January of 1999. Of these, 68 cachectic (body mass index [BMI]<20 kg/m2), 113 overweight (BMI=>27-30 kg/m2), and 55 morbidly obese (BMI>30 kg/m2) patients were compared with 238 normal-weight recipients (BMI=20-27 kg/m2). We evaluated the influence of pretransplant BMI on morbidity and mortality after cardiac transplantation. Kaplan-Meier survival distribution and Cox proportional hazards model were used for statistical analyses. Morbidly obese as well as cachectic recipients demonstrated nearly twice the 5-year mortality of normal-weight or overweight recipients (53% vs. 27%, respectively, P=0.001). An increase in mortality was seen at 30 days for morbidly obese and cachectic recipients (12.7% and 17.7%, respectively) versus a 30-day mortality rate of 7.6% in normal-weight recipients. Morbidly obese recipients experienced a shorter time to high-grade acute rejection (P=0.004) as well as an increased annual high-grade rejection frequency when compared with normal-weight recipients (P=0.001). By multivariable analysis, the incidence of transplant-related coronary artery disease (TCAD) was not increased in morbidly obese patients but cachectic patients had a significantly lower incidence of TCAD (P=0.05). Cachectic patients receiving oversized donor hearts had a significantly higher postoperative mortality (P=0.02). The risks of cardiac transplantation are increased in both morbidly obese and cachectic patients compared with normal-weight recipients. However, the results of cardiac transplantation in overweight patients is comparable to that in normal-weight patients. Recipient size should be kept in mind while selecting patients and the use of oversized donors in cachectic recipients should be avoided.
Boyle, D M
1994-01-01
To discuss and project cancer care needs and a vision of oncology nursing in the next century. Scholarly, professional, and governmental sources of information. Projections of a changed patient/family profile, social support dilemmas, and a new "hybrid" oncology nurse. Opportunities for nurses, resulting from these projections, include roles as minority needs specialist, director of new care-delivery models, facilitator of intergenerational support teams, overseer of neighborhood-based care systems, multispecialty nursing care provider, cancer care policy activist. Nursing education, community models, and current care-delivery settings will all be affected by the projected changes and will all need to consider adjusting to meet the demands that will be placed on them to facilitate change.
NASA Astrophysics Data System (ADS)
Wen, Wen; Li, Haibin; Chen, Xiaojing; Chang, Chengkang
Silica anti-reflective coatings have been prepared by a sol-gel dip-coating process using the sol containing phosphoric acid as a pore-forming template. The effect of the aging time of the sol on the anti-reflective properties has been investigated. The surface topography of the silica AR coatings has been characterized. With increasing sol aging time, more over-sized pores larger than 100 nm are formed in the silica coatings. These could act as scattering centers, scattering visible light and thereby lowering transmittance. The optimal aging time was identified as 1 day, and the corresponding silica coatings showed a maximum transmittance of 99.2%, representing an 8% increase compared to the bare glass substrate.
DNA intermediates and telomere addition during genome reorganization in Euplotes crassus.
Roth, M; Prescott, D M
1985-06-01
Three gene-sized molecules cloned intact from macronuclear DNA served as hybridization probes to study excision of these molecules from chromosomes and their processing during macronuclear development in the hypotrich Euplotes crassus. These molecules occur in integrated forms within polytene chromosomal DNA during macronuclear developmental. After transection of the polytene chromosomes, the three molecules occur in intermediate forms. One of the three molecules first appeared in a large intermediate that was subsequently replaced by a second intermediate, approximately 140 bp larger than the final molecule. The other two macronuclear molecules were detected only in intermediates approximately 140 bp larger than the mature form. These penultimate intermediates are larger by virtue of oversized telomeres, which are pared to yield the mature gene-sized molecules.
Methods and management: NIH administrators, federal oversight, and the Framingham Heart Study.
Patel, Sejal S
2012-01-01
This article explores the 1965 controversy over the Framingham Heart Study in the midst of growing oversight into the management of science at the National Institutes of Health (NIH). It describes how, beginning in the early 1960s, federal overseers demanded that NIH administrators adopt particular management styles in administering programs and how these growing pressures led administrators to favor investigative pursuits that allowed for easy prospective accounting of program payoffs, especially those based on experimental methods designed to examine discrete interventions or outcomes of interest. In light of this changing managerial culture within the NIH, the Framingham study and other population laboratories-with their bases in observation and in open-ended study designs-became harder for NIH administrators to justify and defend.
Ryder, Robert T.; Harris, Anita G.; Repetski, John E.; Crangle, Robert D.; Ruppert, Leslie F.; Ryder, Robert T.
2014-01-01
This chapter is a re-release of U.S. Geological Survey Bulletin 1839-K, of the same title, by Ryder and others (1992; online version 2.0 revised and digitized by Robert D. Crangle, Jr., 2003). It consists of one file of the report text as it appeared in USGS Bulletin 1839-K and a second file containing the cross section, figures 1 and 2, and tables 1 and 2 on one oversized sheet; the second file was digitized in 2003 as version 2.0 and also includes the gamma-ray well log traces.
Trials with errors--preserving the integrity of clinical trials.
Guyer, R L
2000-01-01
The crucial final test of medical research is the clinical trial, which determines whether a drug or discovery really is an effective therapy. All people who participate in clinical trials--researchers, sponsors, volunteers, analysts, reviewers, overseers, others--have opportunities to strengthen or weaken the integrity of the trial system by their behavior. Medical research is now officially married to business, and "profitable" connotes something different to each partner. Only if research and business can profit in parallel will the alliance succeed. Every person who is involved in the medical research business faces temptations and must choose how to react. Each has power and must choose how to wield it. Several centuries before this marriage, the Englishman Izaak Walton noted that "Health is...a blessing that money cannot buy."
Waveguide transition with vacuum window for multiband dynamic nuclear polarization systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rybalko, Oleksandr; Bowen, Sean; Zhurbenko, Vitaliy
2016-05-15
A low loss waveguide transition section and oversized microwave vacuum window covering several frequency bands (94 GHz, 140 GHz, 188 GHz) is presented. The transition is compact and was optimized for multiband Dynamic Nuclear Polarization (DNP) systems in a full-wave simulator. The window is more broadband than commercially available windows, which are usually optimized for single band operation. It is demonstrated that high-density polyethylene with urethane adhesive can be used as a low loss microwave vacuum window in multiband DNP systems. The overall assembly performance and dimensions are found using full-wave simulations. The practical aspects of the window implementation inmore » the waveguide are discussed. To verify the design and simulation results, the window is tested experimentally at the three frequencies of interest.« less
2005-12-16
KENNEDY SPACE CENTER, FLA. - An oversized $434,627.40 check represents the highest amount the NASA civil service work force has ever donated to the Combined Federal Campaign. Standing with the check, from left, are Center Director Jim Kennedy; Dennis Burns, United Way of Brevard, vice president of resource development; Frank Ramsey, United Way of Brevard campaign director; Rob Rains, United Way of Brevard president; and Launch Services Program deputy director Ray Lugo, who served as KSC's Combined Federal Campaign chairperson. The check was presented at a holiday dinner and celebration at KARS Park I on Merritt Island, Fla., hosted by Center Director Jim Kennedy for NASA civil service employees. The theme of the celebration was "Launching Dreams of Those in Need." The event was sponsored by the Change Leaders Network and the Combined Federal Campaign Cabinet.
An experimental study of pressures on 60 deg Delta wings with leading edge vortex flaps
NASA Technical Reports Server (NTRS)
Marchman, J. F., III; Terry, J. E.; Donatelli, D. A.
1983-01-01
An experimental study was conducted in the Virginia Tech Stability Wind Tunnel to determine surface pressures over a 60 deg sweep delta wing with three vortex flap designs. Extensive pressure data was collected to provide a base data set for comparison with computational design codes and to allow a better understanding of the flow over vortex flaps. The results indicated that vortex flaps can be designed which will contain the leading edge vortex with no spillage onto the wing upper surface. However, the tests also showed that flaps designed without accounting for flap thickness will not be optimum and the result can be oversized flaps, early flap vortex reattachment and a second separation and vortex at the wing/flap hinge line.
Methods and Management: NIH Administrators, Federal Oversight, and the Framingham Heart Study
Patel, Sejal S.
2012-01-01
Summary This article explores the 1965 controversy over the Framingham Heart Study in the midst of growing oversight into the management of science at the National Institutes of Health (NIH). It describes how, beginning in the early 1960s, federal overseers demanded that NIH administrators adopt particular management styles in administering programs and how these growing pressures led administrators to favor investigative pursuits that allowed for easy prospective accounting of program payoffs, especially those based on experimental methods designed to examine discrete interventions or outcomes of interest. In light of this changing managerial culture within the NIH, the Framingham study and other population laboratories—with their bases in observation and in open-ended study designs—became harder for NIH administrators to justify and defend. PMID:22643985
Effect of rattling motion without cage structure on lattice thermal conductivity in LaOBiS2-xSex
NASA Astrophysics Data System (ADS)
Lee, C. H.; Nishida, A.; Hasegawa, T.; Nishiate, H.; Kunioka, H.; Ohira-Kawamura, S.; Nakamura, M.; Nakajima, K.; Mizuguchi, Y.
2018-01-01
Low energy phonons in LaOBiS2-xSex are studied using inelastic neutron scattering. Dispersionless flat phonon branches that are mainly associated with a large vibration of Bi atoms are observed at a relatively low energy of E = 6-6.7 meV. The phonon energy softens upon Se doping presumably owing to its heavier atomic mass than the S atom and the expansion of the lattice constant. Simultaneously, the lattice thermal conductivity lowered upon Se doping as the same manner of the phonon softening. These suggest that despite the lack of an oversized cage in LaOBiS2-xSex, rattling motions of Bi atoms can scatter phonon like rattling in cage compounds, contributing to enhance the thermoelectric property.
FInal Report - Investment Casting Shell Cracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Von Richards
2003-12-01
This project made a significant contribution to the understanding of the investment casting shell cracking problem. The effects of wax properties on the occurrence of shell cracking were demonstrated and can be measured. The properties measured include coefficient of thermal expansion, heating rate and crystallinity of the structure. The important features of production molds and materials properties have been indicated by case study analysis and fractography of low strength test bars. It was found that stress risers in shell cavity design were important and that typical critical flaws were either oversize particles or large pores just behind the prime coat.more » It was also found that the true effect of fugitive polymer fibers was not permeability increase, but rather a toughening mechanism due to crack deflection.« less
T-SENSE a millimeter wave scanner for letters
NASA Astrophysics Data System (ADS)
Nüßler, Dirk; Heinen, Sven; Sprenger, Thorsten; Hübsch, Daniel; Würschmidt, Tobais
2013-10-01
Letter bombs are an increasing problem for public authorities, companies and public persons. Nowadays every big company uses in his headquarters inspection system to check the incoming correspondence. Generally x-ray systems are used to inspect complete baskets or bags of letters. This concept which works very fine in big company with a large postal center is not usable for small companies or private persons. For an office environment with a small number of letters x-ray systems are too expensive and oversized. X-ray systems visualize the wires and electric circuits inside the envelope. If a letter contains no metallic components but hazard materials or drugs, the dangerous content is invisible for the most low-cost x-ray systems. Millimeter wave imagining systems offer the potential to close this gap.
Book Holder And Page Turner For The Elderly And Handicapped
NASA Technical Reports Server (NTRS)
Kerley, James; Eklund, Wayne
1993-01-01
Device holds reading matter and facilitates page turning for person not having use of arms and hands. Accommodates variety of publication formats, whether book, magazine, or newspaper. Holder sits on hospital-bed table and adjusted to convenient viewing angle. Includes flat upright back support for reading matter, hinged base, and main bracket with bent-wire page holders. Top support on back extended for such large items as newspapers. Wings on back support extended for oversize materials. Reader turns page by gripping special rod via mouthpiece, applying friction cup at its tip to page, and manipulating rod. Mouthpiece wide and tapered so user grips with teeth and uses jaws to move it, rather than using tongue or lips. Helpful to older people, whose facial and mouth muscles weak.
Mars Radiator Characterization Experimental Program
NASA Technical Reports Server (NTRS)
Witte, Larry C.; Hollingsworth, D. Keith
2004-01-01
Radiators are an enabling technology for the human exploration and development of the moon and Mars. As standard components of the heat rejection subsystem of space vehicles, radiators are used to reject waste heat to space and/or a planetary environment. They are typically large components of the thermal control system for a space vehicle or human habitation facility, and in some cases safety factors are used to oversize them when the operating environment cannot be fully characterized. Over-sizing can impose significant weight and size penalties that might be prohibitive for future missions. Radiator performance depends on the size of the radiator surface, its emittance and absorptance, the radiator temperature, the effective sky temperature surrounding the radiator, solar radiation and atmospheric irradiation levels, convection to or from the atmosphere (on Mars), and other conditions that could affect the nature of the radiator surface, such as dust accumulation. Most particularly, dust is expected to be a major contributor to the local environmental conditions on either the lunar or Martian surface. This conclusion regarding Mars is supported by measurements of dust accumulation on the Mars Sojourner Rover solar array during the Pathfinder mission. This Final Report describes a study of the effect of Martian dust accumulation on radiator performance. It is comprised of quantitative measurements of effective emittance for a range of dust accumulation levels on surfaces of known emittance under clean conditions. The test radiator coatings were Z-93P, NS-43G, and Silver Teflon (10 mil) film. The Martian dust simulant was Carbondale Red Clay. Results were obtained under vacuum conditions sufficient to reduce convection effects virtually to zero. The experiments required the development of a calorimetric apparatus that allows simultaneous measurements of the effective emittance for all the coatings at each set of experimental conditions. A method of adding dust to multiple radiator coupons was developed and shown to be capable of depositing dust on the surfaces with acceptable uniformity. In these experiments, the dust layer accumulates under earth gravity and in the presence of an earth atmosphere. An invention disclosure for the dust deposition apparatus is being filed through NASA and University of Houston.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tharp, Tim; Martin, David; Franco, Paul
2013-07-01
Waste Management personnel at the Y-12 National Security Complex (Y-12) are concluding a multi-year effort to dispose of a large backlog of low-level waste. Six containers presented a particularly difficult technical challenge in that they each contained large robust equipment (mostly salt baths) with elevated levels of highly enriched uranium (exceeding U.S. Department of Transportation (DOT) fissile-excepted quantities). The equipment was larger than the standard 1.2 m x 1.2 m x 1.8 m (4 ft x 4 ft x 6 ft) DOT Specification 7A Type A box and would have been very difficult to size-reduce because of several inches ofmore » steel plate (along with insulating block and concrete) in the equipment design. A critical breakthrough for the success of the project involved procuring and developing two oversize reusable DOT Specification 7A Type A (fissile tested) containers (referred to as the CTI Model 7AF-690-SC) that could be used as overpacks for the original boxes of equipment. The 7A Type A overpack containers are approximately 3.5 m long x 2.7 m wide x 2.8 m high (11.7 ft x 8.9 ft x 9.2 ft) with a maximum gross weight of 10,660 kg (23,500 lb) and a payload capacity of 6,804 kg (15,000 lbs). The boxes were designed and fabricated using a split cavity design that allowed the gasketed and bolted closure to lie along the horizontal centerline of the box. The central closure location in this design allows for strengthening of box corners that tend to be points of weakness or failure in 49CFR173.465 drop tests. By combining the split cavity design with large diameter tubing and diagonal cross bracing, drop test requirements of 49CFR173.465(1) and (2) were met and demonstrated through finite element analysis modeling. The development and use of this new container dramatically reduced the need for down-sizing the equipment and allowed the project to meet objectives within cost and schedule targets. (authors)« less
CAD/CAM transtibial prosthetic sockets from central fabrication facilities: How accurate are they?
Sanders, Joan E.; Rogers, Ellen L.; Sorenson, Elizabeth A.; Lee, Gregory S.; Abrahamson, Daniel C.
2014-01-01
This research compares transtibial prosthetic sockets made by central fabrication facilities with their corresponding American Academy of Orthotists and Prosthetists (AAOP) electronic shape files and assesses the central fabrication process. We ordered three different socket shapes from each of 10 manufacturers. Then we digitized the sockets using a very accurate custom mechanical digitizer. Results showed that quality varied considerably among the different manufacturers. Four of the companies consistently made sockets within +/−1.1% volume (approximately 1 sock ply) of the AAOP electronic shape file, while six other companies did not. Six of the companies showed consistent undersizing or oversizing in their sockets, which suggests a consistent calibration or manufacturing error. Other companies showed inconsistent sizing or shape distortion, a difficult problem that represents a most challenging limitation for central fabrication facilities. PMID:18247236
Adaptive array technique for differential-phase reflectometry in QUEST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Idei, H., E-mail: idei@triam.kyushu-u.ac.jp; Hanada, K.; Zushi, H.
2014-11-15
A Phased Array Antenna (PAA) was considered as launching and receiving antennae in reflectometry to attain good directivity in its applied microwave range. A well-focused beam was obtained in a launching antenna application, and differential-phase evolution was properly measured by using a metal reflector plate in the proof-of-principle experiment at low power test facilities. Differential-phase evolution was also evaluated by using the PAA in the Q-shu University Experiment with Steady State Spherical Tokamak (QUEST). A beam-forming technique was applied in receiving phased-array antenna measurements. In the QUEST device that should be considered as a large oversized cavity, standing wave effectmore » was significantly observed with perturbed phase evolution. A new approach using derivative of measured field on propagating wavenumber was proposed to eliminate the standing wave effect.« less
NASA Technical Reports Server (NTRS)
Moua, Cheng M.; Cox, Timothy H.; McWherter, Shaun C.
2008-01-01
The Quiet Spike(TradeMark) F-15B flight research program investigated supersonic shock reduction using a 24-ft telescoping nose boom on an F-15B airplane. The program goal was to collect flight data for model validation up to 1.8 Mach. In the area of stability and controls, the primary concerns were to assess the potential destabilizing effect of the oversized nose boom on the stability, controllability, and handling qualities of the airplane and to ensure adequate stability margins across the entire research flight envelope. This paper reports on the stability and control analytical methods, flight envelope clearance approach, and flight test results of the F-15B telescoping nose boom configuration. Also discussed are brief pilot commentary on typical piloting tasks and refueling tasks.
Practical UAV Optical Sensor Bench with Minimal Adjustability
NASA Technical Reports Server (NTRS)
Pilgrim, Jeffrey; Gonzales, Paula
2013-01-01
A multiple-pass optical platform eliminates essentially all optical alignment degrees of freedom, save one. A four-pass absorption spectrometer architecture is made rigid by firmly mounting dielectric-coated mirror prisms with no alignment capability to the platform. The laser diode beam is collimated by a small, custom-developed lens, which has only a rotational degree of freedom along the standard optical "z" axis. This degree is itself eliminated by adhesive after laser collimation. Only one degree of freedom is preserved by allowing the laser diode chip and mount subassembly to move relative to the collimating lens by using over-sized mounting holes. This allows full 360 deg motion of a few millimeters relative to the lens, which, due to the high numerical aperture of the lens, provides wide directional steering of the collimated laser beam.
Method for forming a liquid cooled airfoil for a gas turbine
Grondahl, Clayton M.; Willmott, Leo C.; Muth, Myron C.
1981-01-01
A method for forming a liquid cooled airfoil for a gas turbine is disclosed. A plurality of holes are formed at spaced locations in an oversized airfoil blank. A pre-formed composite liquid coolant tube is bonded into each of the holes. The composite tube includes an inner member formed of an anti-corrosive material and an outer member formed of a material exhibiting a high degree of thermal conductivity. After the coolant tubes have been bonded to the airfoil blank, the airfoil blank is machined to a desired shape, such that a portion of the outer member of each of the composite tubes is contiguous with the outer surface of the machined airfoil blank. Finally, an external skin is bonded to the exposed outer surface of both the machined airfoil blank and the composite tubes.
1968-01-01
This photograph was taken at the Redstone airfield, Huntsville, Alabama, during the unloading of the Saturn V S-IVB stage that housed the Orbital Workshop (OWS) from the Super Guppy, the NASA plane that was specially built to carry oversized cargo. The OWS measured 22 feet (6.7 m) in diameter, and 48 feet (14.6 m) in length. The Saturn V S-IVB stage was modified at the McDornell Douglas facility at Huntington Beach, California, for a new role, which was to house the OWS. In addition to the test articles, engineering mockups, and flight equipment, both McDonnell Douglas and Martin Marietta built 0-G trainers, neutral buoyancy trainers, and high-fidelity mockups for the 1-G trainer to be used in the KC-135 aircraft. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
["Do not do" also as regards tobacco].
Olano-Espinosa, Eduardo; Minué-Lorenzo, César
2016-01-01
We do have very effective and efficient interventions to help our patients to stop smoking. The strategy that has more evidence and consensus in primary care is the 5 A's, that is, ask, advise, assess willingness to try to quit smoking, helping those who want to try and make follow-up visits. However, we intervene lot less than we should. The available protocols oversized interventions, and propose elements without scientific evidence or therapeutic effect. It is therefore necessary to develop more simple, useful and evidence-based interventions to assist us in carrying out our work interventions, and stop doing those that dońt contribute. In this article we will use as an example a critical review of Smoker Care Service Portfolio of Madrid Health Service, and we will propose a number of alternatives to allow a simple, effective and evidence-based intervention. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
NASA Astrophysics Data System (ADS)
Yashiki, Satoshi; Ueda, Kazuo
2011-08-01
Effect of anharmonicity of a cage potential for a magnetic ion vibrating in a metal is investigated by the numerical renormalization group method. The cage potential is assumed to be one-dimensional and of the double-well type. In the absence of the Coulomb interaction, we find continuous crossover among the three limiting cases: Yu--Anderson-type Kondo regime, the double-well-type Kondo one, and the renormalized Fermi chain one. In the entire parameter space of the double-well potential, the ground state is described by a local Fermi liquid. In the Yu--Anderson-type Kondo regime, a quantum phase transition to the ground state with odd parity takes place passing through the two-channel Kondo fixed point when the Coulomb interaction increases. Therefore, the vibration of a magnetic ion in an oversized cage structure is a promising route to the two-channel Kondo effect.
Retrospective view of airborne dust levels in workplace of a chrysotile mine in Ural, Russia.
Kashansky, S V; Domnin, S G; Kochelayev, V A; Monakhov, D D; Kogan, F M
2001-04-01
The Bazhenovskoye chrysotile asbestos deposit has been exploited for 115 years. All the technological operations in the quarry are accompanied by the formation of high-dispersion asbestos-containing aerosols. The dust concentrations at the miner's working places for the last 30 years (1970-2000) were at or below the Russian MACs(m.s.) level (4.0 mg/m3). The seasonal precipitation amount in the deposit area causes a rise in dust content in certain periods. The maximum density of asbestos respirable fibres exceeded 2.7 f/cm3. All the identified fibres belonged to chrysotile asbestos, and no amphibole asbestos, such as tremolite asbestos, has been identified. An excessive dust level remains, despite the dust content level decrease, at the work sites of oversized lump drillers and unloaders, and oncopathology heightened risk remains in these occupational groups, as a result.
Trailing Ballute Aerocapture: Concept and Feasibility Assessment
NASA Technical Reports Server (NTRS)
Miller, Kevin L.; Gulick, Doug; Lewis, Jake; Trochman, Bill; Stein, Jim; Lyons, Daniel T.; Wilmoth, Richard G.
2003-01-01
Trailing Ballute Aerocapture offers the potential to obtain orbit insertion around a planetary body at a fraction of the mass of traditional methods. This allows for lower costs for launch, faster flight times and additional mass available for science payloads. The technique involves an inflated ballute (balloon-parachute) that provides aerodynamic drag area for use in the atmosphere of a planetary body to provide for orbit insertion in a relatively benign heating environment. To account for atmospheric, navigation and other uncertainties, the ballute is oversized and detached once the desired velocity change (Delta V) has been achieved. Analysis and trades have been performed for the purpose of assessing the feasibility of the technique including aerophysics, material assessments, inflation system and deployment sequence and dynamics, configuration trades, ballute separation and trajectory analysis. Outlined is the technology development required for advancing the technique to a level that would allow it to be viable for use in space exploration missions.
Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T
2017-04-01
A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Advancements in water vapor electrolysis technology. [for Space Station ECLSS
NASA Technical Reports Server (NTRS)
Chullen, Cinda; Heppner, Dennis B.; Sudar, Martin
1988-01-01
The paper describes a technology development program whose goal is to develop water vapor electrolysis (WVE) hardware that can be used selectively as localized topping capability in areas of high metabolic activity without oversizing the central air revitalization system on long-duration manned space missions. The WVE will be used primarily to generate O2 for the crew cabin but also to provide partial humidity control by removing water vapor from the cabin atmosphere. The electrochemically based WVE interfaces with cabin air which is controlled in the following ranges: dry bulb temperature of 292 to 300 K; dew point temperature of 278 to 289 K; relative humidity of 25 to 75 percent; and pressure of 101 + or - 1.4 kPa. Design requirements, construction details, and results for both single-cell and multicell module testing are presented, and the preliminary sizing of a multiperson subsystem is discussed.
NASA Astrophysics Data System (ADS)
Li, Zebo; Trinkle, Dallas R.
2017-04-01
We use a continuum method informed by transport coefficients computed using self-consistent mean field theory to model vacancy-mediated diffusion of substitutional Si solutes in FCC Ni near an a/2 [1 1 ¯0 ] (111 ) edge dislocation. We perform two sequential simulations: first under equilibrium boundary conditions and then under irradiation. The strain field around the dislocation induces heterogeneity and anisotropy in the defect transport properties and determines the steady-state vacancy and Si distributions. At equilibrium both vacancies and Si solutes diffuse to form Cottrell atmospheres with vacancies accumulating in the compressive region above the dislocation core while Si segregates to the tensile region below the core. Irradiation raises the bulk vacancy concentration, driving vacancies to flow into the dislocation core. The out-of-equilibrium vacancy fluxes drag Si atoms towards the core, causing segregation to the compressive region, despite Si being an oversized solute in Ni.
Self-locking double retention redundant pull pin release
NASA Technical Reports Server (NTRS)
Killgrove, Thomas O. (Inventor)
1987-01-01
A double-retention redundant pull pin release system is disclosed. The system responds to a single pull during an intentional release operation. A spiral-threaded main pin is seated in a mating bore in a housing, which main pin has a flange fastened thereon at the part of the main pin which is exterior to the housing. Accidental release tends to rotate the main pin. A secondary pin passes through a slightly oversized opening in the flange and is seated in a second bore in the housing. The pins counteract against one another to prevent accidental release. A frictional lock is shared between the main and secondary pins to enhance further locking of the system. The secondary pin, in response to a first pull, is fully retracted from its bore and flange hole. Thereafter the pull causes the main pin to rotate free of the housing to release, for example, a parachute mechanism.
Graft downsizing during ex vivo lung perfusion: case report and technical notes.
Nosotti, M; Rosso, L; Mendogni, P; Tosi, D; Palleschi, A; Righi, I; Froio, S; Valenza, F; Santambrogio, L
2014-09-01
Among patients with respiratory insufficiency awaiting lung transplantation, small adult patients have a lower opportunity of receiving size-matched pulmonary grafts, because of the shortage of donors, particularly those of small size. Reducing the size of an oversized graft is one of the methods to increase the donor pool; similarly, ex vivo lung perfusion is an emerging technique aimed toward the same purpose. We describe how we combined the 2 techniques (lobar transplantation plus contralateral nonanatomic graft reduction during ex vivo lung perfusion) to overcome graft shortage in a clinical case. For the 1st time, this case report demonstrates that surgical manipulation during ex vivo lung perfusion does not affect the functional improvement in a lung previously judged to be not suitable for transplantation. The 6-month follow-up results are similar to those of standard bilateral lung transplantation. Copyright © 2014 Elsevier Inc. All rights reserved.
Method and technique for installing light-weight, fragile, high-temperature fiber insulation
NASA Technical Reports Server (NTRS)
Patel, B. C. (Inventor)
1983-01-01
A method of installing fragile, light weight, high temperature fiber insulation, particularly where the insulation is to be used as a seal strip providing a high order of thermal barrier insulation is discussed. The process is based on provision of a strip of the mineral batting cut oversize by a predetermined amount, saturated in a fugitive polymer solution, compressed in a mold, dried and cured to form a rigidized batting material which is machined to required shape. The machine dimensions would normally be at least nominally less than the dimensions of the cavity to be sealed. After insertion in the cavity, which may be a wire-mesh seal enclosure, the apparatus is subjected to baking at a temperature sufficiently high to cause the resin to burn off cleanly, leaving the batting substantially in its original condition and expanded into the cavity or seal enclosure.
A method and technique for installing light-weight fragile, high-temperature fiber insulation
NASA Technical Reports Server (NTRS)
Ballantine, T. J. (Inventor)
1982-01-01
A method of installing fragile, light-weight, high-temperature fiber insulation, particularly where the insulation is to be used as a seal strip providing a high order of thermal barrier insulation is described. The process is based on provision of a strip of the mineral batting cut oversize by a predetermined amount, saturated in a fugitive polymer solution, compressed in a mold, dried and cured to form a rigidized batting material which may be machined to required shape. The machined dimensions would normally be at least nominally less than the dimensions of the cavity to be sealed. After insertion in the cavity, which may be a wire-mesh seal enclosure, the apparatus is subjected to baking at a temperature sufficiently high to cause the resin to burn off cleanly, leaving the batting substantially in its original condition and expanded into the cavity or seal enclosure.
Jaff, Jennifer C; Arnold, Janis; Bousvaros, Athos
2006-08-01
In addition to their physical challenges, children and adolescents with inflammatory bowel disease (IBD) living in the United States face a number of administrative and regulatory hurdles that affect their quality of life. This article, written by a physician, attorney/patient advocate, and social worker, discusses a number of these challenges and describes how the provider can help his or her patient overcome them. Specifically, the article discusses 4 areas in detail: appeals of denials of coverage from insurance companies and third party payors; assisting children with IBD with classroom and school accommodations; assisting uninsured children in obtaining Social Security benefits; and aiding a parent to care for their child using the Family and Medical Leave Act. Although this article has a pediatric focus, adults have similar advocacy needs. Case examples and sample letters to third-party payors, schools, and employers are included in this article.
Design of Xen Hybrid Multiple Police Model
NASA Astrophysics Data System (ADS)
Sun, Lei; Lin, Renhao; Zhu, Xianwei
2017-10-01
Virtualization Technology has attracted more and more attention. As a popular open-source virtualization tools, XEN is used more and more frequently. Xsm, XEN security model, has also been widespread concern. The safety status classification has not been established in the XSM, and it uses the virtual machine as a managed object to make Dom0 a unique administrative domain that does not meet the minimum privilege. According to these questions, we design a Hybrid multiple police model named SV_HMPMD that organically integrates multiple single security policy models include DTE,RBAC,BLP. It can fullfill the requirement of confidentiality and integrity for security model and use different particle size to different domain. In order to improve BLP’s practicability, the model introduce multi-level security labels. In order to divide the privilege in detail, we combine DTE with RBAC. In order to oversize privilege, we limit the privilege of domain0.
Special report: Occlusive cuff controller
NASA Technical Reports Server (NTRS)
Baker, J. T.
1975-01-01
A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
K. Payette; D. Tillman
During the period October 1, 2002--December 31, 2002, Allegheny Energy Supply Co., LLC (Allegheny) completed the first year of testing at the Willow Island cofiring project. This included data acquisition and analysis associated with certain operating parameters and environmental results. Over 2000 hours of cofiring operation were logged at Willow Island, and about 4,000 tons of sawdust were burned along with slightly more tire-derived fuel (TDF). The results were generally favorable. During this period, also, a new grinder was ordered for the Albright Generating Station to handle oversized material rejected by the disc screen. This report summarizes the activities associatedmore » with the Designer Opportunity Fuel program, and demonstrations at Willow Island and Albright Generating Stations. It details the test results at Willow Island and summarizes the grinder program at Albright.« less
Nanoscale Liquid Jets Shape New Line of Business
NASA Technical Reports Server (NTRS)
2003-01-01
Just as a pistol shrimp stuns its prey by quickly closing its oversized claw to shoot out a shock-inducing, high-velocity jet of water, NanoMatrix, Inc., is sending shockwaves throughout the nanotechnology world with a revolutionary, small-scale fabrication process that uses powerful liquid jets to cut and shape objects. Emanuel Barros, a former project engineer at NASA s Ames Research Center, set out to form the Santa Cruz, California-based NanoMatrix firm and materialize the micro/nano cutting process partially inspired by the water-spewing crustacean. Early on in his 6-year NASA career, Barros led the development of re-flown flight hardware for an award-winning Spacelab project called NeuroLab. This project, the sixteenth and final Spacelab mission, focused on a series of experiments to determine the effects of microgravity on the development of the mammalian nervous system.
A manipulator arm for zero-g simulations
NASA Technical Reports Server (NTRS)
Brodie, S. B.; Grant, C.; Lazar, J. J.
1975-01-01
A 12-ft counterbalanced Slave Manipulator Arm (SMA) was designed and fabricated to be used for resolving the questions of operational applications, capabilities, and limitations for such remote manned systems as the Payload Deployment and Retrieval Mechanism (PDRM) for the shuttle, the Free-Flying Teleoperator System, the Advanced Space Tug, and Planetary Rovers. As a developmental tool for the shuttle manipulator system (or PDRM), the SMA represents an approximate one-quarter scale working model for simulating and demonstrating payload handling, docking assistance, and satellite servicing. For the Free-Flying Teleoperator System and the Advanced Tug, the SMA provides a near full-scale developmental tool for satellite servicing, docking, and deployment/retrieval procedures, techniques, and support equipment requirements. For the Planetary Rovers, it provides an oversize developmental tool for sample handling and soil mechanics investigations. The design of the SMA was based on concepts developed for a 40-ft NASA technology arm to be used for zero-g shuttle manipulator simulations.
Propagation Characteristics of International Space Station Wireless Local Area Network
NASA Technical Reports Server (NTRS)
Sham, Catherine C.; Hwn, Shian U.; Loh, Yin-Chung
2005-01-01
This paper describes the application of the Uniform Geometrical Theory of Diffraction (UTD) for Space Station Wireless Local Area Networks (WLANs) indoor propagation characteristics analysis. The verification results indicate good correlation between UTD computed and measured signal strength. It is observed that the propagation characteristics are quite different in the Space Station modules as compared with those in the typical indoor WLANs environment, such as an office building. The existing indoor propagation models are not readily applicable to the Space Station module environment. The Space Station modules can be regarded as oversized imperfect waveguides. Two distinct propagation regions separated by a breakpoint exist. The propagation exhibits the guided wave characteristics. The propagation loss in the Space Station, thus, is much smaller than that in the typical office building. The path loss model developed in this paper is applicable for Space Station WLAN RF coverage and link performance analysis.
Pay attention to reflux/feed entry design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fleming, B.; Martin, G.R.; Hartman, E.L.
1996-01-01
Trays generally are forgiving pieces of equipment and can conceal the effects of poorly designed feed and reflux entries. When one tries to push a tower to its hydraulic limit, however, poor entry design can penalize the performance of the trays and result in a lower final capacity. Normally, new towers are not as susceptible to entry design problems as ones being revamped. This is because new towers usually have some degree of capacity oversizing.Standard design practices used for new columns having spare capacity, though, may not be suitable for revamped towers. In this article, the authors detail the basicmore » principles of reflux and feed entry design, good practices to follow, and poor practices to avoid. They also include a case study of a large-diameter light hydrocarbon splitter revamped with high capacity trays to illustrate the potential pitfalls associated with incorrectly designed reflux and feed entry arrangements.« less
Simulation investigation of a Ku-band radial line oscillator operating at low guiding magnetic field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dang, Fangchao, E-mail: dangfangchao@sina.com; Zhang, Xiaoping; Zhong, Huihuang
2014-06-15
A novel radial line oscillator operating at Ku-band with low guiding magnetic field is proposed in this paper. By using an oversized radial structure, the power handling capacity is enhanced significantly. Based on the small-signal theory, the π/2 mode in radial TM{sub 01} mode is selected as the working mode. Furthermore, a radial uniform guiding magnetic field, made up of four solenoids, is designed. As indicated in 2.5-dimensional fully electromagnetic particle-in-cell simulation, high power microwaves with a power of 2.2 GW and a frequency of 14.25 GHz are generated with over 40% efficiency when the electron beam voltage is 300 kV, themore » beam current 18 kA, and the guiding magnetic field is only 0.6 T. There is no angular non-asymmetric mode discovered in three-dimensional simulation.« less
NASA Technical Reports Server (NTRS)
1987-01-01
In swine farming 15 to 25 percent of piglets die before weaning, and that poses a serious economic problem for hog producers. Sometimes a sow will accidentally crush her piglets or she will reject or abuse a piglet. Frequently a litter is oversized and the sow cannot accommodate all her piglets for nursing or is just unable to lactate due to physical disorders. Farmatic Inc.'s mechanical mother pig comes in two models, one with eight artificial nipples and another with 16. Shortly before feeding time the automated sow releases a prescribed amount of formula from a refrigerated compartment into a warming chamber, where milk is heated to the desired temperature. At feeding time a heat lamp simulating a sow's body warmth is automatically turned on and the machine emits rhythmic grunts like a mother pig summoning her piglets. As piglets scamper to their mechanical mother, a panel across the front opens to expose the row of nipples.
Lai, WeiJen; Midorikawa, Yoshiyuki; Kanno, Zuisei; Takemura, Hiroshi; Suga, Kazuhiro; Soga, Kohei; Ono, Takashi; Uo, Motohiro
2016-12-01
We developed a device to evaluate the orthodontic force applied by systems requiring high operability. A life-sized, two-tooth model was designed, and the measurements were performed using a custom-made jointed attachment, referred to as an "action stick", to allow clearance for the oversized six-axis sensors. This tooth-sensor apparatus was accurately calibrated, and the error was limited. Vector analysis and rotating coordinate transformation were required to derive the force and moment at the tooth from the sensor readings. The device was then used to obtain measurements of the force and moment generated by the V-bend system. Our device was effective, providing results that were consistent with those of previous studies. This measurement device can be manufactured with force sensors of any size, and it can also be expanded to models with any number of teeth.
Noise and performance calibration study of a Mach 2.2 supersonic cruise aircraft
NASA Technical Reports Server (NTRS)
Mascitti, V. R.; Maglieri, D. J.
1979-01-01
The baseline configuration of a Mach 2.2 supersonic cruise concept employing a 1980 - 1985 technology level, dry turbojet, mechanically suppressed engine, was calibrated to identify differences in noise levels and performance as determined by the methodology and ground rules used. In addition, economic and noise information is provided consistent with a previous study based on an advanced technology Mach 2.7 configuration, reported separately. Results indicate that the difference between NASA and manufacturer performance methodology is small. Resizing the aircraft to NASA groundrules results in negligible changes in takeoff noise levels (less than 1 EPNdB) but approach noise is reduced by 5.3 EPNdB as a result of increasing approach speed. For the power setting chosen, engine oversizing resulted in no reduction in traded noise. In terms of summated noise level, a 6 EPNdB reduction is realized for a 5% increase in total operating costs.
Motion of the guest ion as precursor to the first-order phase transition in the cage system GdB6
NASA Astrophysics Data System (ADS)
Iwasa, Kazuaki; Igarashi, Ryosuke; Saito, Kotaro; Laulhé, Claire; Orihara, Toshihiko; Kunii, Satoru; Kuwahara, Keitaro; Nakao, Hironori; Murakami, Youichi; Iga, Fumitoshi; Sera, Masafumi; Tsutsui, Satoshi; Uchiyama, Hiroshi; Baron, Alfred Q. R.
2011-12-01
The motion of guest Gd ions in oversized boron cages in GdB6 was investigated from phonon spectra measurements obtained by inelastic x-ray scattering. The measured phonon modes soften by about 10% from 300 K down to TN=16 K, in particular, the longitudinal phonon for the propagation vector q1=(1/2,0,0) that characterizes the distorted structure below TN. Besides, the dispersion relation curves show kinklike anomalies at qk=(0.38,0.38,0). The observed results imply that the motion of the guest Gd ion interplays with the f electrons magnetoelastically and with carriers via Fermi surface nesting. The anomalous properties previously reported for this material far above TN originate from the strong electron-phonon coupling, which causes the motion of guest ions as precursors to the first-order phase transition.
NASA Astrophysics Data System (ADS)
Gore, J.; Pasternack, G. B.; Wiener, J.
2016-12-01
Process-based river classification tends to be done at reach to catchment scales assuming channels are uniform and thus differentiated by the simple specific stream power metric. In fact, mountain rivers are highly variable at subreach scales to the point that local topographic steering may be the dominant control on geomorphic processes. This study presents a new framework for characterizing how stage-dependent topographic steering varies continuously down a river, leading to a classification of subreach landforms on the basis of the geomorphic mechanism of flow convergence routing. The two remote mountain river segments were located in the 3480-km2 Yuba River, with the upper South Yuba having a substantial sediment supply from legacy hydraulic gold mining and the mainstem Yuba downstream of New Bullards Bar Dam having a restricted sediment supply. Meter-scale DEMs were produced for both cases using airborne LiDAR and survey data. DEMs were slope detrended to focus the analysis on cross-sectional variability. DEMs were then heavily smoothed to allow for automated tracing of the valley centerline, and then cross-sectional rectangles were spaced every 5 m. The average width (W) and detrended bed elevation (Z) of the wetted area was computed from the DEM for each raster for 6-7 different river stages. Both width and cross-sectionally averaged bed elevation were standardized. The product of these two variables was computed as a measure of cross-sectional area, and is termed the geomorphic covariance (Czw) series when plotted along each river corridor. Cwz was then used to classify each cross-section as one of five distinct landform types: nozzle, wide bar, normal channel, constricted pool, and oversized pool- with this classification varying with discharge such that a section could, for example, function as a nozzle during low flow but an oversized pool at high flow, or any other combination. Longitudinal profiles of bed elevation, width, covariance, and landform type were analyzed for their stage-dependent patterns to understand their geomorphic significance and to contrast the two rivers. This new method may be the first example of a hierarchical, process-based classification at the subreach scale in which one mechanism is assessed for how it varies not only in space, but as a function of discharge.
Towards Cryogenic Liquid-Vapor Energy Storage Units for space applications
NASA Astrophysics Data System (ADS)
Afonso, Josiana Prado
With the development of mechanical coolers and very sensitive cryogenic sensors, it could be interesting to use Energy Storage Units (ESU) and turn off the cryocooler to operate in a free micro vibration environment. An ESU would also avoid cryogenic systems oversized to attenuate temperature fluctuations due to thermal load variations which is useful particularly for space applications. In both cases, the temperature drift must remain limited to keep good detector performances. In this thesis, ESUs based on the high latent heat associated to liquid-vapor phase change to store energy have been studied. To limit temperature drifts while keeping small size cell at low temperature, a potential solution consists in splitting the ESU in two volumes: a low temperature cell coupled to a cryocooler cold finger through a thermal heat switch and an expansion volume at room temperature to reduce the temperature increase occurring during liquid evaporation. To obtain a vanishing temperature drift, a new improvement has been tested using two-phase nitrogen: a controlled valve was inserted between the two volumes in order to control the cold cell pressure. In addition, a porous material was used inside the cell to turn the ESU gravity independent and suitable for space applications. In this case, experiments reveal not fully understood results concerning both energy storage and liquid-wall temperature difference. To capture the thermal influence of the porous media, a dedicated cell with poorly conductive lateral wall was built and operated with two-phase helium. After its characterization outside the saturation conditions (conduction, convection), experiments were performed, with and without porous media, heating at the top or the bottom of the cell with various heat fluxes and for different saturation temperatures. In parallel, a model describing the thermal response for a cell containing liquid and vapor with a porous medium heated at the top ("against gravity") was developed. The experimental data were then used as a benchmark for this model based on a balance of three forces: capillarity force, gravity force and pressure drop induced by the liquid flow.
Donath, Ernest E.
1976-01-01
A method and apparatus for removing oversized, unentrained char particles from a two-stage coal gasification process so as to prevent clogging or plugging of the communicating passage between the two gasification stages. In the first stage of the process, recycled process char passes upwardly while reacting with steam and oxygen to yield a first stage synthesis gas containing hydrogen and oxides of carbon. In the second stage, the synthesis gas passes upwardly with coal and steam which react to yield partially gasified char entrained in a second stage product gas containing methane, hydrogen, and oxides of carbon. Agglomerated char particles, which result from caking coal particles in the second stage and are too heavy to be entrained in the second stage product gas, are removed through an outlet in the bottom of the second stage, the particles being separated from smaller char particles by a counter-current of steam injected into the outlet.
NASA Technical Reports Server (NTRS)
1980-01-01
Several features of the interactions of the Solar Power Satellite (SPS) with its space environment are examined theoretically. The voltages produced at various surfaces due to space plasmas and the plasma leakage currents through the kapton and sapphire solar cell blankets are calculated. At geosynchronous orbit, this parasitic power loss is only 0.7%, and is easily compensated by oversizing. At low Earth orbit, the power loss is potentially much larger (3%), and anomalous arcing is expected for the EOTV high voltage negative surfaces. Preliminary results of a three dimensional self consistent plasma and electric field computer program are presented, confirming the validity of the predictions made from the one dimensional models. Lastly, magnetic shielding of the satellite is considered to reduce the power drain and to protect the solar cells from energetic electron and plasma ion bombardment. It is concluded that minor modifications can allow the SPS to operate safely and efficiently in its space environment. Subsequent design changes will substantially alter the basic conclusions.
Redox and the circadian clock in plant immunity: A balancing act.
Karapetyan, Sargis; Dong, Xinnian
2018-05-01
Plants' reliance on sunlight for energy makes their light-driven circadian clock a critical regulator in balancing the energy needs for vital activities such as growth and defense. Recent studies show that the circadian clock acts as a strategic planner to prime active defense responses towards the morning or daytime when conditions, such as the opening of stomata required for photosynthesis, are favorable for attackers. Execution of the defense response, on the other hand, is determined according to the cellular redox state and is regulated in part by the production of reactive oxygen and nitrogen species upon pathogen challenge. The interplay between redox and the circadian clock further gates the onset of defense response to a specific time of the day to avoid conflict with growth-related activities. In this review, we focus on discussing the roles of the circadian clock as a robust overseer and the cellular redox as a dynamic executor of plant defense. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smirnov, A. V.; Agustsson, R.; Berg, W. J.
We report observations of an intense sub-THz radiation extracted from a ~3 MeV electron beam with a flat transverse profile propagating between two parallel oversized copper gratings with side openings. Low-loss radiation outcoupling is accomplished using a horn antenna and a miniature permanent magnet separating sub-THz and electron beams. A tabletop experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet with a movable beam scraper producing sub-mm microbunches. The radiated energy of tens of micro-Joules per radio frequency macropulse is demonstrated. The frequency of the radiation peak was generated and tunedmore » across two frequency ranges: (476–584) GHz with 7% instantaneous spectrum bandwidth, and (311–334) GHz with 38% instantaneous bandwidth. In this study, the prototype setup features a robust compact source of variable frequency, narrow bandwidth sub-THz pulses.« less
Tools to Perform Local Dense 3D Reconstruction of Shallow Water Seabed ‡
Avanthey, Loïca; Beaudoin, Laurent; Gademer, Antoine; Roux, Michel
2016-01-01
Tasks such as distinguishing or identifying individual objects of interest require the production of dense local clouds at the scale of these individual objects of interest. Due to the physical and dynamic properties of an underwater environment, the usual dense matching algorithms must be rethought in order to be adaptive. These properties also imply that the scene must be observed at close range. Classic robotized acquisition systems are oversized for local studies in shallow water while the systematic acquisition of data is not guaranteed with divers. We address these two major issues through a multidisciplinary approach. To efficiently acquire on-demand stereoscopic pairs using simple logistics in small areas of shallow water, we devised an agile light-weight dedicated system which is easy to reproduce. To densely match two views in a reliable way, we devised a reconstruction algorithm that automatically accounts for the dynamics, variability and light absorption of the underwater environment. Field experiments in the Mediterranean Sea were used to assess the results. PMID:27196913
Flexible Mechanical Conveyors for Regolith Extraction and Transport
NASA Technical Reports Server (NTRS)
Walton, Otis R.; Vollmer, Hubert J.
2013-01-01
A report describes flexible mechanical conveying systems for transporting fine cohesive regolith under microgravity and vacuum conditions. They are totally enclosed, virtually dust-free, and can include enough flexibility in the conveying path to enable an expanded range of extraction and transport scenarios, including nonlinear drill-holes and excavation of enlarged subsurface openings without large entry holes. The design of the conveyors is a modification of conventional screw conveyors such that the central screw-shaft and the outer housing or conveyingtube have a degree of bending flexibility, allowing the conveyors to become nonlinear conveying systems that can convey around gentle bends. The central flexible shaft is similar to those used in common tools like a weed whacker, consisting of multiple layers of tightly wound wires around a central wire core. Utilization of compliant components (screw blade or outer wall) increases the robustness of the conveying, allowing an occasional oversized particle to pass hough the conveyor without causing a jam or stoppage
[Public sector and social and health policy reforms. An inventory on the eve of the new millennium].
Gerschman, S
1999-01-01
This study reflects on reforms in health systems and social policies within the framework of the so-called public sector reforms. The point of departure is a review of various explanations for the crisis in the Welfare State, present in the literature from the 1990s. Social policies, at the heart of the crisis, are heavily challenged. What we intend to demonstrate is that this argument plays a specific role, that of introducing neoliberal changes into economic policy, in which the economic tools used generate abstention by the state from the social sphere, deregulation of national economies in favor of the free market, and the fundamentally oversized role of the international financial market. Within this context we analyze the social security and health system reforms. The final part of the article deals with current difficulties in social policies, focusing the debate on a mapping of possible alternatives for developing social and health policies.
Co-digestion of sewage sludge from external small WWTP's in a large plant
NASA Astrophysics Data System (ADS)
Miodoński, Stanisław
2017-11-01
Improving energy efficiency of WWTPs (Waste Water Treatment Plants) is crucial action of modern wastewater treatment technology. Technological treatment process optimization is important but the main goal will not be achieved without increasing production of renewable energy from sewage sludge in anaerobic digestion process which is most often used as sludge stabilization method on large WWTP's. Usually, anaerobic digestion reactors used for sludge digestion were designed with reserve and most of them is oversized. In many cases that reserve is unused. On the other hand, smaller WWTPs have problem with management of sewage sludge due to lack of adequately developed infrastructure for sludge stabilization. Paper shows an analysis of using a technological reserve of anaerobic digestion reactors at large WWTP (1 million P.E.) for sludge stabilization collected from smaller WWTP in a co-digestion process. Over 30 small WWTPs from the same region as the large WWTP were considered in this study. Furthermore, performed analysis included also evaluation of potential sludge disintegration pre-treatment for co-digestion efficiency improvement.
Psychologically Informed Implementations of Sugary-Drink Portion Limits
John, Leslie K.; Donnelly, Grant E.; Roberto, Christina A.
2017-01-01
In 2012, the New York City Board of Health prohibited restaurants from selling sugary drinks in containers that would hold more than 16 oz. Although a state court ruled that the Board of Health did not have the authority to implement such a policy, it remains a legally viable option for governments and a voluntary option for restaurants. However, there is very limited empirical data on how such a policy might affect the purchasing and consumption of sugary drinks. We report four well-powered, incentive-compatible experiments in which we evaluated two possible ways that restaurants might comply with such a policy: bundling (i.e., dividing the contents of oversized cups into two regulation-size cups) and providing free refills (i.e., offering a regulation-size cup with unlimited refills). Bundling caused people to buy less soda. Free refills increased consumption, especially when a waiter served the refills. This perverse effect was reduced in self-service contexts that required walking just a few steps to get a refill. PMID:28362567
Application of a Probalistic Sizing Methodology for Ceramic Structures
NASA Astrophysics Data System (ADS)
Rancurel, Michael; Behar-Lafenetre, Stephanie; Cornillon, Laurence; Leroy, Francois-Henri; Coe, Graham; Laine, Benoit
2012-07-01
Ceramics are increasingly used in the space industry to take advantage of their stability and high specific stiffness properties. Their brittle behaviour often leads to size them by increasing the safety factors that are applied on the maximum stresses. It induces to oversize the structures. This is inconsistent with the major driver in space architecture, the mass criteria. This paper presents a methodology to size ceramic structures based on their failure probability. Thanks to failure tests on samples, the Weibull law which characterizes the strength distribution of the material is obtained. A-value (Q0.0195%) and B-value (Q0.195%) are then assessed to take into account the limited number of samples. A knocked-down Weibull law that interpolates the A- & B- values is also obtained. Thanks to these two laws, a most-likely and a knocked- down prediction of failure probability are computed for complex ceramic structures. The application of this methodology and its validation by test is reported in the paper.
Wheel slip dump valve for railway braking system
NASA Astrophysics Data System (ADS)
Zhang, Xuan; Zhang, LiHao; Li, QingXuan; Shi, YanTao
2017-09-01
As we all know, pneumatic braking system plays an important role in the safety of the whole vehicle. In the anti slip braking system, the pressure of braking cylinder can be adjusted by the quick power response of wheel slip dump valve, so that the lock situation won’t occur during vehicle service. During the braking of railway vehicles, the braking force provided by braking disc reduces vehicle’s speed. But the locking slip will happen due to the oversize of braking force or the reduction of sticking coefficient between wheel and rail. It will cause not only the decline of braking performance but also the increase of braking distance. In the meanwhile, it will scratch the wheel and influence the stable running of vehicles. Now, the speed of passenger vehicle has been increased. In order to shorten the braking distance as far as possible, sticking stickiness must be fully applied. So the occurrence probability of wheel slip is increased.
Smirnov, A. V.; Agustsson, R.; Berg, W. J.; ...
2015-09-29
We report observations of an intense sub-THz radiation extracted from a ~3 MeV electron beam with a flat transverse profile propagating between two parallel oversized copper gratings with side openings. Low-loss radiation outcoupling is accomplished using a horn antenna and a miniature permanent magnet separating sub-THz and electron beams. A tabletop experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet with a movable beam scraper producing sub-mm microbunches. The radiated energy of tens of micro-Joules per radio frequency macropulse is demonstrated. The frequency of the radiation peak was generated and tunedmore » across two frequency ranges: (476–584) GHz with 7% instantaneous spectrum bandwidth, and (311–334) GHz with 38% instantaneous bandwidth. In this study, the prototype setup features a robust compact source of variable frequency, narrow bandwidth sub-THz pulses.« less
Crystal structure of the pyrochlore oxide superconductor KOs{sub 2}O{sub 6}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamaura, Jun-Ichi; Yonezawa, Shigeki; Muraoka, Yuji
2006-01-15
We report the single-crystal X-ray analysis of the structure of the pyrochlore oxide superconductor KOs{sub 2}O{sub 6}. The structure was identified as the {beta}-pyrochlore structure with space group Fd3-bar m and lattice constant a=10.089(2)A at 300K: the K atom is located at the 8b site, not at the 16d site as in conventional pyrochlore oxides. We found an anomalously large atomic displacement parameter U{sub iso}=0.0735(8)A{sup 2} at 300K for the K cation, which suggests that the K cation weakly bound to an oversized Os{sub 12}O{sub 18} cage exhibits intensive rattling, as recently observed for clathrate compounds. The rattling of Amore » cations is a common feature in the series of {beta}-pyrochlore oxide superconductors AOs{sub 2}O{sub 6} (A=Cs, Rb and K), and is greatest for the smallest K cation.« less
Wide scanning spherical antenna
NASA Technical Reports Server (NTRS)
Shen, Bing (Inventor); Stutzman, Warren L. (Inventor)
1995-01-01
A novel method for calculating the surface shapes for subreflectors in a suboptic assembly of a tri-reflector spherical antenna system is introduced, modeled from a generalization of Galindo-Israel's method of solving partial differential equations to correct for spherical aberration and provide uniform feed to aperture mapping. In a first embodiment, the suboptic assembly moves as a single unit to achieve scan while the main reflector remains stationary. A feed horn is tilted during scan to maintain the illuminated area on the main spherical reflector fixed throughout the scan thereby eliminating the need to oversize the main spherical reflector. In an alternate embodiment, both the main spherical reflector and the suboptic assembly are fixed. A flat mirror is used to create a virtual image of the suboptic assembly. Scan is achieved by rotating the mirror about the spherical center of the main reflector. The feed horn is tilted during scan to maintain the illuminated area on the main spherical reflector fixed throughout the scan.
Steam drum design for direct steam generation
NASA Astrophysics Data System (ADS)
Willwerth, Lisa; Müller, Svenja; Krüger, Joachim; Succo, Manuel; Feldhoff, Jan Fabian; Tiedemann, Jörg; Pandian, Yuvaraj; Krüger, Dirk; Hennecke, Klaus
2017-06-01
For the direct steam generation in solar fields, the recirculation concept has been demonstrated in several installations. Water masses in the solar field vary during transient phases, such as passing clouds. The volume of the steam drum can serve as a buffer during such transients by taking in excess water and providing water storage. The saturated steam mass flow to the superheating section or the consumer can be maintained almost constant during short transients; therefore the steam drum plays a key role for constant steam supply. Its buffer effect depends on the right sizing of the steam drum for the prevailing situations. Due to missing experiences, steam drums have been sized under conservative assumptions and are thereby usually oversized. With this paper, experiences on the steam drum of the 5 MWel TSE1 power plant are discussed for optimized future plant design. The results are also of relevance for process heat installations, in which saturated steam is produced by the solar field.
Method and apparatus for separating material
Oder, Robin R.; Jamison, Russell E.
2006-10-24
An apparatus for sorting particles composed of a mixture of particles with differing physical and chemical characteristics. The apparatus includes a comminutor, a mechanism for removing particles from the inside of the comminutor which are intermediate in size between the feed to the comminutor and the product of comminution, a mechanism for either discharging particles taken from the comminutor to a reject stream or providing them to a size classification apparatus such as screening, a mechanism for returning the oversize particles to the comminutor or for discharging them to the reject stream, an electric mechanism for separating particles with an electrical force disposed adjacent to a magnet mechanism, a mechanism for providing the particles to the magnet mechanism and the electric mechanism and for providing triboelectric and capacitive charges to the particles, and a mechanism for returning one of the products of electric and magnetic separation to the comminutor while discharging the other to the reject stream. A method for sorting particles composed of a mixture of particles with differing physical and chemical characteristics.
Jet noise and performance comparison study of a Mach 2.55 supersonic cruise aircraft
NASA Technical Reports Server (NTRS)
Mascitti, V. R.; Maglieri, D. J.
1979-01-01
Data provided by the manufacturer relating to noise and performance of a Mach 2.55 supersonic cruise concept employing a post 1985 technology level, variable cycle engine was used to identify differences in noise levels and performance between the manfacturer and NASA associated with methodology and groundrules. In addition, economic and noise information is provided consistent with a previous study based on an advanced technology Mach 2.7 configuration. The results indicate that the difference between the NASA's and manfacturer's performance methodology is small. Resizing the aircraft to NASA groundrules also results in small changes in flyover, sideline and approach noise levels. For the power setting chosen, engine oversizing resulted in no reduction in traded noise. In terms of summated noise level, a 10 EPNdB reduction is realized for an 8 percent increase in total operating costs. This corresponds to an average noise reduction of 3.3 EPNdB at the three observer positions.
NASA Astrophysics Data System (ADS)
Joshi, Abhijeet Bhaskar
The origin of the lower back pain is often the degenerated lumbar intervertebral disc (IVD). We are proposing replacement of the degenerated nucleus by a PVA/PVP polymeric hydrogel implant. We hypothesize that a polymeric hydrogel nucleus implant can restore the normal biomechanics of the denucleated IVD by mimicking the natural load transfer phenomenon as in case of the intact IVD. Lumbar IVDs (n = 15) were harvested from human cadavers. In the first part, specimens were tested in four different conditions for compression: Intact, bone in plug, denucleated and Implanted. Hydrogel nucleus implants were chosen to have line-to-line fit in the created nuclear cavity. In the second part, nucleus implant material (modulus) and geometric (height and diameter) parameters were varied and specimens (n = 9) were tested. Nucleus implants with line-to-line fit significantly restored (88%) the compressive stiffness of the denucleated IVD. The synergistic effect between the implant and the intact annulus resulted in the nonlinear increase in implanted IVD stiffness, where Poisson effect of the hydrogel played major role. Nucleus implant parameters were observed to have a significant effect on the compressive stiffness. All implants with modulus in the tested range restored the compressive stiffness. The undersize implants resulted in incomplete restoration while oversize implants resulted in complete restoration compared to the BI condition. Finite element models (FEM) were developed to simulate the actual test conditions and validated against the experimental results for all conditions. The annulus (defined as hyperelastic, isotropic) mainly determined the nonlinear response of the IVD. Validated FEMs predicted 120--3000 kPa as a feasible range for nucleus implant modulus. FEMs also predicted that overdiameter implant would be more effective than overheight implant in terms of stiffness restoration. Underdiameter implants, initially allowed inward deformation of the annulus and hence were less effective compared to underheight implants. This research successfully proved the feasibility of PVA/PVP polymeric hydrogel as a replacement for degenerated nucleus. This approach may reduce the abnormal stresses on the annulus and thus, prevent/postpone the degeneration of the annulus. A validated FEM can be used as a design tool for optimization of hydrogel nucleus implants design and related feasibility studies.
NASA Astrophysics Data System (ADS)
Teyssier, J.; Lortz, R.; Petrovic, A.; van der Marel, D.; Filippov, V.; Shitsevalova, N.
2008-10-01
We report a detailed study of specific heat, electrical resistivity, and optical spectroscopy in the superconducting boride LuB12 (Tc=0.4K) , and compare it to the higher Tc compound ZrB12 (Tc=6K) . Both compounds have the same structure based on enclosed metallic Lu or Zr ions in oversized boron cages. The infrared reflectivity and ellipsometry in the visible range allow us to extract the optical conductivity from 6 meV to 4 eV in the normal state from 20 to 280 K. By extracting the superconducting properties, phonon density of states, and electron-phonon coupling function from these measurements, we discuss the important factors governing Tc and explain the difference between the two compounds. The phonon density of states seems to be insignificantly modified by substitution of Zr with Lu. However, the soft vibrations of the metal ions in boron cages, responsible for the relatively high Tc in ZrB12 , have almost no contribution to the electron-phonon coupling in LuB12 .
Electrostatic protection of the Solar Power Satellite and rectenna
NASA Technical Reports Server (NTRS)
Freeman, J. W.; Few, A. A., Jr.; Reiff, P. H.; Cooke, D.; Bohannon, J.; Haymes, B.
1979-01-01
Several features of the interactions of the solar power satellite (SPS) with its space environment were examined theoretically. The voltages produced at various surfaces due to space plasmas and the plasma leakage currents through the kapton and sapphire solar cell blankets were calculated. At geosynchronous orbit, this parasitic power loss is only 0.7%, and is easily compensated by oversizing. At low-Earth orbit, the power loss is potentially much larger (3%), and anomalous arcing is expected for the EOTV high voltage negative surfaces. Preliminary results of a three dimensional self-consistent plasma and electric field computer program are presented, confirming the validity of the predictions made from the one dimensional models. Magnetic shielding of the satellite, to reduce the power drain and to protect the solar cells from energetic electron and plasma ion bombardment is considered. It is concluded that minor modifications can allow the SPS to operate safely and efficiently in its space environment. The SPS design employed in this study is the 1978 MSFC baseline design utilizing GaAs solar cells at CR-2 and an aluminum structure.
Testing of the Gemini secondary mirrors
NASA Astrophysics Data System (ADS)
Otto, Wolfgang
1999-09-01
The first 1-m secondary mirror for the Gemini 8-m telescopes project was delivered by Zeiss in 1998, and 2nd mirror will be delivered in the summer of 1999. For first use during commissioning we produced an extreme lightweight Zerodur solution prefabricated at Schott. To reach the 85 percent weight reduction a novel etching technique was used. INterferometric testing was done performing full aperture measurements using a concave matrix. In progress with the fabrication process of the matrix we applied 3D-mechanical measurements, IR-interferometry, and VIS-interferometry using null lenses to reach the final intrinsic quality of 6 nm rms. For interferometric testing of the secondaries phase shifting interferometry with a tunable laser diode was applied. The optical test results of the secondaries show, that the mirrors are well within specification. The finally achieved intrinsic surface quality is 17 nm rms for Unit 1 and 13 nm rms for Unit 2, dominated by cutting effects which were introduced by removing the oversize at the inner and outer edge of the mirror after the final polishing step.
Liang, Weihua; Liu, Yushan; Ge, Baoming; ...
2017-09-08
The battery energy stored quasi-Z-source (BESqZS) based photovoltaic (PV) power generation system combines advantages of the qZS inverter and the battery energy storage system. But, the second harmonic (2ω) power ripple degrades the system’s performance and affects the system’s design. An accurate model to analyze the 2ω ripple is very important. The existing models did not consider the battery, or assumed a symmetric qZS network with L 1=L 2 and C 1=C 2, which limits the design freedom and causes oversized impedance parameters. Our paper proposes a comprehensive model for the single-phase BES-qZS-PV inverter system, where the battery is consideredmore » and there is no restriction of L 1=L 2 and C 1=C 2. Based on the built model, a BES-qZS impedance design method is proposed to mitigate the 2ω ripple with asymmetric qZS network. Simulation and experimental results verify the proposed 2ω ripple model and impedance design method.« less
Computer-socket manufacturing error: How much before it is clinically apparent?
Sanders, Joan E.; Severance, Michael R.; Allyn, Kathryn J.
2015-01-01
The purpose of this research was to pursue quality standards for computer-manufacturing of prosthetic sockets for people with transtibial limb loss. Thirty-three duplicates of study participants’ normally used sockets were fabricated using central fabrication facilities. Socket-manufacturing errors were compared with clinical assessments of socket fit. Of the 33 sockets tested, 23 were deemed clinically to need modification. All 13 sockets with mean radial error (MRE) greater than 0.25 mm were clinically unacceptable, and 11 of those were deemed in need of sizing reduction. Of the remaining 20 sockets, 5 sockets with interquartile range (IQR) greater than 0.40 mm were deemed globally or regionally oversized and in need of modification. Of the remaining 15 sockets, 5 sockets with closed contours of elevated surface normal angle error (SNAE) were deemed clinically to need shape modification at those closed contour locations. The remaining 10 sockets were deemed clinically acceptable and not in need modification. MRE, IQR, and SNAE may serve as effective metrics to characterize quality of computer-manufactured prosthetic sockets, helping facilitate the development of quality standards for the socket manufacturing industry. PMID:22773260
Stiffness after total knee arthroplasty.
Manrique, Jorge; Gomez, Miguel M; Parvizi, Javad
2015-04-01
Stiffness after total knee arthroplasty (TKA) adversely affects outcome and impacts patient function. Various risk factors for stiffness after TKA have been identified, including reduced preoperative knee range of motion, history of prior knee surgery, etiology of arthritis, incorrect positioning or oversizing of components, and incorrect gap balancing. Mechanical and associated causes, such as infection, arthrofibrosis, complex regional pain syndrome, and heterotopic ossification, secondary gain issues have also been identified. Management of stiffness following TKA can be challenging. The condition needs to be assessed and treated in a staged manner. A nonsurgical approach is the first step. Manipulation under anesthesia may be considered within the first 3 months after the index TKA, if physical therapy fails to improve the range of motion. Beyond this point, consideration should be given to surgical intervention such as lysis of adhesions, either arthroscopically or by open arthrotomy. If the cause of stiffness is deemed to be surgical error, such as component malpositioning, revision arthroplasty is indicated. The purpose of this article is to evaluate the various aspects of management of stiffness after TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Determination of Survivable Fires
NASA Technical Reports Server (NTRS)
Dietrich, D. L.; Niehaus, J. E.; Ruff, G. A.; Urban, D. L.; Takahashi, F.; Easton, J. W.; Abbott, A. A.; Graf, J. C.
2012-01-01
At NASA, there exists no standardized design or testing protocol for spacecraft fire suppression systems (either handheld or total flooding designs). An extinguisher's efficacy in safely suppressing any reasonable or conceivable fire is the primary benchmark. That concept, however, leads to the question of what a reasonable or conceivable fire is. While there exists the temptation to over-size' the fire extinguisher, weight and volume considerations on spacecraft will always (justifiably) push for the minimum size extinguisher required. This paper attempts to address the question of extinguisher size by examining how large a fire a crew member could successfully survive and extinguish in the confines of a spacecraft. The hazards to the crew and equipment during an accidental fire include excessive pressure rise resulting in a catastrophic rupture of the vehicle skin, excessive temperatures that burn or incapacitate the crew (due to hyperthermia), carbon dioxide build-up or other accumulation of other combustion products (e.g. carbon monoxide). Estimates of these quantities are determined as a function of fire size and mass of material burned. This then becomes the basis for determining the maximum size of a target fire for future fire extinguisher testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Weihua; Liu, Yushan; Ge, Baoming
The battery energy stored quasi-Z-source (BESqZS) based photovoltaic (PV) power generation system combines advantages of the qZS inverter and the battery energy storage system. But, the second harmonic (2ω) power ripple degrades the system’s performance and affects the system’s design. An accurate model to analyze the 2ω ripple is very important. The existing models did not consider the battery, or assumed a symmetric qZS network with L 1=L 2 and C 1=C 2, which limits the design freedom and causes oversized impedance parameters. Our paper proposes a comprehensive model for the single-phase BES-qZS-PV inverter system, where the battery is consideredmore » and there is no restriction of L 1=L 2 and C 1=C 2. Based on the built model, a BES-qZS impedance design method is proposed to mitigate the 2ω ripple with asymmetric qZS network. Simulation and experimental results verify the proposed 2ω ripple model and impedance design method.« less
Major, Thomas W.; Carey, Jason P.; Nobes, David S.; Major, Paul W.
2010-01-01
In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the slot's top and bottom, angles between walls, slot taper, and the linearity of each wall. Slot dimensions for 30 upper right central incisor self-ligating stainless steel brackets from three manufacturers were evaluated. Speed brackets have a slot height 2% smaller than the nominal 0.559 mm size and have a slightly convergent taper. In-Ovation brackets have a divergent taper at an average angle of 1.47 degrees. In-Ovation is closest to the nominal value of slot height at the slot base and has the smallest manufacturing tolerances. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. Damon slot height is on average 3% oversized. PMID:20981299
Squeezing clathrate cages to host trivalent rare-earth guests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jian; He, Yuping; Mordvinova, Natalia E.
Strike difference of the trivalent rare-earth cations from their alkali and alkaline-earth peers is in the presence of localized 4f-electrons and strong spin-orbit coupling. Placing trivalent rare-earth cations inside the fullerene molecules or in between the blocks of itinerant magnetic intermetallics gave rise to plethora of fascinating properties and materials. A long-time missing but hardly desired piece is the semiconducting or metallic compound where rare-earth cations are situated inside the oversized polyhedral cages of three-dimensional framework. In this work we present a synthesis of such compounds, rare-earth containing clathrates Ba 8-xR xCu 16P 30. The unambiguous proofs of their compositionmore » and crystal structure were achieved by a combination of synchrotron powder diffraction, time-of-flight neutron powder diffraction, scanning-transmission electron microscopy, and electron energy-loss spectroscopy. Our quantum-mechanical calculations and experimental characterizations show that the incorporation of the rare-earth cations significantly enhances the hole mobility and concentration which results in the drastic increase in the thermoelectric performance.« less
The 1906 earthquake and a century of progress in understanding earthquakes and their hazards
Zoback, M.L.
2006-01-01
The 18 April 1906 San Francisco earthquake killed nearly 3000 people and left 225,000 residents homeless. Three days after the earthquake, an eight-person Earthquake Investigation Commission composed of 25 geologists, seismologists, geodesists, biologists and engineers, as well as some 300 others started work under the supervision of Andrew Lawson to collect and document physical phenomena related to the quake . On 31 May 1906, the commission published a preliminary 17-page report titled "The Report of the State Earthquake Investigation Commission". The report included the bulk of the geological and morphological descriptions of the faulting, detailed reports on shaking intensity, as well as an impressive atlas of 40 oversized maps and folios. Nearly 100 years after its publication, the Commission Report remains a model for post-earthquake investigations. Because the diverse data sets were so complete and carefully documented, researchers continue to apply modern analysis techniques to learn from the 1906 earthquake. While the earthquake marked a seminal event in the history of California, it served as impetus for the birth of modern earthquake science in the United States.
First photometric study of the W UMa system GSC 1042-2191
NASA Astrophysics Data System (ADS)
Bulut, A.; Bulut, İ.; Demircan, O.
2016-04-01
We present new photometric observations covering eight minima times for the eclipsing binary GSC 1042-2191. The light curves in BVRI colors were analyzed by using WD-code for the system parameters. Eight minima times were obtained from the new observations. The system is found a low mass ratio (q = 0.148), A-type over-contact binary with a fill out parameter of f = 65.01 ± 12.18%. The preliminary absolute dimensions (M1= 1.26 ± 0.06 M⊙, M2 = 0.18 ± 0.06 M⊙, R1 = 1.54 ± 0.20 R⊙, R2 = 0.69 ± 0.01 R⊙, L1 =3.30 ± 0.30 L⊙ and L2 = 0.59 ± 0.20 L⊙) indicate the very much oversized and over-luminous secondary component, by assuming the present luminosity of the secondary is its main sequence luminosity, we predict the original mass is about 0.8 M⊙, this means the present secondary could be transferred and/or lost 77% of its original mass and only its core is left.
NASA Technical Reports Server (NTRS)
Riley, Donald R.; Glaab, Louis J.; Brandon, Jay M.; Person, Lee H., Jr.; Glaab, Patricia C.
1999-01-01
A piloted simulation study was performed for the purpose of indicating the noise reduction benefits and piloting performance that could occur for a typical 4-engine high-Speed Civil Transport (HSCT) configuration during takeoff when a dual thrust-cutback procedure was employed with throttle operation under direct computer control. Two thrust cutbacks were employed with the first cutback performed while the vehicle was accelerating on the run-way and the second cutback performed at a distance farther downrange. Added vehicle performance improvements included the incorporation of high-lift increments into the aerodynamic database of the vehicle and the use of limited engine oversizing. Four single-stream turbine bypass engines that had no noise suppression of any kind were used with this configuration. This approach permitted establishing the additional noise suppression level that was needed to meet Federal Air Regulation Part 36 Stage 3 noise levels for subsonic commercial jet aircraft. Noise level results were calculated with the jet mixing and shock noise modules of the Aircraft Noise Prediction Program (ANOPP).
Energy materials coordinating committee (EMACC) Fiscal Year 1982. Annual technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
1983-03-01
The DOE Energy Materials Coordinating Committee (EMaCC) serves primarily to enhance coordination among the Department's materials programs and to further the effective use of materials expertise within the Department. These functions are accomplished through the exchange of budgetary and planning information among program managers and through technical meetings/ workshops on selected topics involving both DOE and major contractors. In addition, the EMaCC aids in obtaining materials - related inputs for both intra- and interagency compilations. Membership in the EMaCC is open to any Department organizational unit; participants are appointed by Division or Office Directors. The current membership is listed inmore » Table 1. The EMACC reports to the Director of the Office of Energy Research in his capacity as overseer of the technical programs of the Department. This annual technical report is mandated by the EMACC terms of reference. In this report are described 1) EMACC activities for FY 1982; 2) a summary of materials funding in the Department from FY 1978 to the present; and 3) on-going materials programs in the Department.« less
Improving device performance of perovskite solar cells by micro-nanoscale composite mesoporous TiO2
NASA Astrophysics Data System (ADS)
Ting, Hungkit; Zhang, Danfei; He, Yihao; Wei, Shiyuan; Li, Tieyi; Sun, Weihai; Wu, Cuncun; Chen, Zhijian; Wang, Qi; Zhang, Guoyi; Xiao, Lixin
2018-02-01
In perovskite solar cells, the morphology of the porous TiO2 electron transport layer (ETL) largely determines the quality of the perovskites. Here, we chose micro-scale TiO2 (0.2 µm) and compared it with the conventional nanoscale TiO2 (20 nm) in relation to the crystallinity of perovskites. The results show that the micro-scale TiO2 is favorable for increasing the grain size of the perovskites and enhancing the light scattering. However, the oversized TiO2 results in an uneven surface. The evenness of the perovskites can be improved by nanoscale TiO2, while the crystallinity and compactness are not as good as those of the films based on micro-scale TiO2. To combine the advantages of both micro-scale and nanoscale TiO2, by mixing 0.2 µm/20 nm TiO2 with a ratio of 1:2 as the composite ETL, the device average power conversion efficiency was increased to 11.2% from 9.9% in the case of only 20 nm TiO2.
Wireline-rotary air coring of the Bandelier Tuff, Los Alamos, New Mexico
Teasdale, W.E.; Pemberton, R.R.
1984-01-01
This paper describes experiments using wireline-rotary air-coring techniques conducted in the Bandelier Tuff using a modified standard wireline core-barrel system. The modified equipment was used to collect uncontaminated cores of unconsolidated ash and indurated tuff at Los Alamos, New Mexico. Core recovery obtained from the 210-foot deep test hole was about 92 percent. A standard HQ-size, triple-tube wireline core barrel (designed for the passage of liquid drilling fluids) was modified for air coring as follows: (1) Air passages were milled in the latch body part of the head assembly; (2) the inside dimension of the outer core barrel tube was machined and honed to provide greater clearance between the inner and outer barrels; (3) oversized reaming devices were added to the outer core barrel and the coring bit to allow more clearance for air and cuttings return; (4) the eight discharge ports in the coring bit were enlarged. To control airborne-dust pollution, a dust-and-cuttings discharge subassembly, designed and built by project personnel, was used. (USGS)
Zhang, Fei; Vanmeensel, Kim; Batuk, Maria; Hadermann, Joke; Inokoshi, Masanao; Van Meerbeek, Bart; Naert, Ignace; Vleugels, Jef
2015-04-01
Latest trends in dental restorative ceramics involve the development of full-contour 3Y-TZP ceramics which can avoid chipping of veneering porcelains. Among the challenges are the low translucency and the hydrothermal stability of 3Y-TZP ceramics. In this work, different trivalent oxides (Al2O3, Sc2O3, Nd2O3 and La2O3) were selected to dope 3Y-TZP ceramics. Results show that dopant segregation was a key factor to design hydrothermally stable and high-translucent 3Y-TZP ceramics and the cation dopant radius could be used as a controlling parameter. A large trivalent dopant, oversized as compared to Zr(4+), exhibiting strong segregation at the ZrO2 grain boundary was preferred. The introduction of 0.2 mol% La2O3 in conventional 0.1-0.25 wt.% Al2O3-doped 3Y-TZP resulted in an excellent combination of high translucency and superior hydrothermal stability, while retaining excellent mechanical properties. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Effects of alloying elements on thermal desorption of helium in Ni alloys
NASA Astrophysics Data System (ADS)
Xu, Q.; Cao, X. Z.; Sato, K.; Yoshiie, T.
2012-12-01
It is well known that the minor elements Si and Sn can suppress the formation of voids in Ni alloys. In the present study, to investigate the effects of Si and Sn on the retention of helium in Ni alloys, Ni, Ni-Si, and Ni-Sn alloys were irradiated by 5 keV He ions at 723 K. Thermal desorption spectroscopy (TDS) was performed at up to 1520 K, and microstructural observations were carried out to identify the helium trapping sites during the TDS analysis. Two peaks, at 1350 and 1457 K, appeared in the TDS spectrum of Ni. On the basis of the microstructural observations, the former peak was attributed to the release of trapped helium from small cavities and the latter to its release from large cavities. Small-cavity helium trapping sites were also found in the Ni-Si and Ni-Sn alloys, but no large cavities were observed in these alloys. In addition, it was found that the oversized element Sn could trap He atoms in the Ni-Sn alloy.
NASA Astrophysics Data System (ADS)
Löw, Fabian; Schorcht, Gunther; Michel, Ulrich; Dech, Stefan; Conrad, Christopher
2012-10-01
Accurate crop identification and crop area estimation are important for studies on irrigated agricultural systems, yield and water demand modeling, and agrarian policy development. In this study a novel combination of Random Forest (RF) and Support Vector Machine (SVM) classifiers is presented that (i) enhances crop classification accuracy and (ii) provides spatial information on map uncertainty. The methodology was implemented over four distinct irrigated sites in Middle Asia using RapidEye time series data. The RF feature importance statistics was used as feature-selection strategy for the SVM to assess possible negative effects on classification accuracy caused by an oversized feature space. The results of the individual RF and SVM classifications were combined with rules based on posterior classification probability and estimates of classification probability entropy. SVM classification performance was increased by feature selection through RF. Further experimental results indicate that the hybrid classifier improves overall classification accuracy in comparison to the single classifiers as well as useŕs and produceŕs accuracy.
2D net shape weaving for cost effective manufacture of textile reinforced composites
NASA Astrophysics Data System (ADS)
Vo, D. M. P.; Kern, M.; Hoffmann, G.; Cherif, C.
2017-10-01
Despite significant weight and performance advantages over metal parts, the today’s demand for fibre-reinforced polymer composites (FRPC) has been limited mainly by their large manufacturing cost. The combination of dry textile preforms and low-cost consolidation processes such as resin transfer molding (RTM) has been appointed as a promising approach to low-cost FRPC manufacture. At the current state of the art, tooling and impregnation technology is well understood whereas preform fabrication technology has not been developed effectively. This paper presents an advanced 2D net shape weaving technology developed with the aim to establish a more cost effective system for the manufacture of dry textile preforms for FRPC. 2D net shape weaving is developed based on open reed weave (ORW) technology and enables the manufacture of 2D contoured woven fabrics with firm edge, so that oversize cutting and hand trimming after molding are no longer required. The introduction of 2D net shape woven fabrics helps to reduce material waste, cycle time and preform manufacturing cost significantly. Furthermore, higher grade of automation in preform fabrication can be achieved.
Cnidarian Nerve Nets and Neuromuscular Efficiency.
Satterlie, Richard A
2015-12-01
Cnidarians are considered "nerve net animals" even though their nervous systems include various forms of condensation and centralization. Yet, their broad, two-dimensional muscle sheets are innervated by diffuse nerve nets. Do the motor nerve nets represent a primitive organization of multicellular nervous systems, do they represent a consequence of radial symmetry, or do they offer an efficient way to innervate a broad, two-dimensional muscle sheet, in which excitation of the muscle sheet can come from multiple sites of initiation? Regarding the primitive nature of cnidarian nervous systems, distinct neuronal systems exhibit some adaptations that are well known in higher animals, such as the use of oversized neurons with increased speed of conduction, and condensation of neurites into nerve-like tracts. A comparison of neural control of two-dimensional muscle sheets in a mollusc and jellyfish suggests that a possible primitive feature of cnidarian neurons may be a lack of regional specialization into conducting and transmitting regions. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.
Packaging, Transportation and Recycling of NPP Condenser Modules - 12262
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polley, G.M.
2012-07-01
Perma-Fix was awarded contract from Energy Northwest for the packaging, transportation and disposition of the condenser modules, water boxes and miscellaneous metal, combustibles and water generated during the 2011 condenser replacement outage at the Columbia Generating Station. The work scope was to package the water boxes and condenser modules as they were removed from the facility and transfer them to the Perma-Fix Northwest facility for processing, recycle of metals and disposition. The condenser components were oversized and overweight (the condenser modules weighed ∼102,058 kg [225,000 lb]) which required special equipment for loading and transport. Additional debris waste was packaged inmore » inter-modals and IP-1 boxes for transport. A waste management plan was developed to minimize the generation of virtually any waste requiring landfill disposal. The Perma-Fix Northwest facility was modified to accommodate the ∼15 m [50-ft] long condenser modules and equipment was designed and manufactured to complete the disassembly, decontamination and release survey. The condenser modules are currently undergoing processing for free release to a local metal recycler. Over three millions pounds of metal will be recycled and over 95% of the waste generated during this outage will not require land disposal. There were several elements of this project that needed to be addressed during the preparation for this outage and the subsequent packaging, transportation and processing. - Staffing the project to support 24/7 generation of large components and other wastes. - The design and manufacture of the soft-sided shipping containers for the condenser modules that measured ∼15 m X 4 m X 3 m [50 ft X 13 ft X 10 ft] and weighed ∼102,058 kg [225,000 lbs] - Developing a methodology for loading the modules into the shipping containers. - Obtaining a transport vehicle for the modules. - Designing and modifying the processing facility. - Movement of the modules at the processing facility. If any of these issues were not adequately resolved prior to the start of the outage, costly delays would result and the re-start of the power plant could be impacted. The main focus of this project was to find successful methods for keeping this material out of the landfills and preserving the natural resources. In addition, this operation provided a significant cost savings to the public utility by minimizing landfill disposal. The onsite portion of the project has been completed without impact to the overall outage schedule. By the date of presentation, the majority of the waste from the condenser replacement project will have been processed and recycled. The goals for this project included helping Energy Northwest maintain the outage schedule, package and characterize waste compliantly, perform transportation activities in compliance with 49CFR (Ref-1), and minimize the waste disposal volume. During this condenser replacement project, over three millions pounds of waste was generated, packaged, characterized and transported without injury or incident. It is anticipated that 95% of the waste generated during this project will not require landfill disposal. All of the waste is scheduled to be processed, decontaminated and recycled by June of 2012. (authors)« less
Large Modal Survey Testing Using the Ibrahim Time Domain Identification Technique
NASA Technical Reports Server (NTRS)
Ibrahim, S. R.; Pappa, R. S.
1985-01-01
The ability of the ITD identification algorithm in identifying a complete set of structural modal parameters using a large number of free-response time histories simultaneously in one analysis, assuming a math model with a high number of degrees-of-freedom, has been studied. Identification results using simulated free responses of a uniform rectangular plate, with 225 measurement stations, and experimental responses from a ground vibration test of the Long Duration Exposure Facility (LDEF) Space Shuttle payload, with 142 measurement stations, are presented. As many as 300 degrees-of-freedom were allowed in analyzing these data. In general, the use of a significantly oversized math model in the identification process was found to maintain or increase identification accuracy and to identify modes of low response level that are not identified with smaller math model sizes. The concept of a Mode Shape Correlation Constant is introduced for use when more than one identification analysis of the same structure are conducted. This constant quantifies the degree of correlation between any two sets of complex mode shapes identified using different excitation conditions, different user-selectable algorithm constants, or overlapping sets of measurements.
Large modal survey testing using the Ibrahim time domain /ITD/ identification technique
NASA Technical Reports Server (NTRS)
Ibrahim, S. R.; Pappa, R. S.
1981-01-01
The ability of the ITD identification algorithm in identifying a complete set of structural modal parameters using a large number of free-response time histories simultaneously in one analysis, assuming a math model with a high number of degrees-of-freedom, has been studied. Identification results using simulated free responses of a uniform rectangular plate, with 225 measurement stations, and experimental responses from a ground vibration test of the Long Duration Exposure Facility (LDEF) Space Shuttle payload, with 142 measurement stations, are presented. As many as 300 degrees-of-freedom were allowed in analyzing these data. In general, the use of a significantly oversized math model in the identification process was found to maintain or increase identification accuracy and to identify modes of low response level that are not identified with smaller math model sizes. The concept of a Mode Shape Correlation Constant is introduced for use when more than one identification analysis of the same structure are conducted. This constant quantifies the degree of correlation between any two sets of complex mode shapes identified using different excitation conditions, different user-selectable algorithm constants, or overlapping sets of measurements.
Marine pisolites from Upper Proterozoic carbonates of East Greenland and Spitsbergen
NASA Technical Reports Server (NTRS)
Swett, K.; Knoll, A. H.
1989-01-01
Upper Proterozoic carbonate successions from central East Greenland (the Limestone-Dolomite 'Series' of the Eleonore Bay Group) and Svalbard (the Backlundtoppen Formation of the Akademikerbreen) Group, Spitsbergen, and the Upper Russo Formation of the Raoldtoppen Group, Nordaustlandet) contain thick sequences dominated by pisolites. These rocks were generated in shallow marine environments, and the pisoids are essentially oversized ooids. A marine environment is supported by the thickness and lateral extent of the carbonates; by a sedimentary association of pisolites with stromatolites, flake-conglomerates, calcarenites, calcilutites, microphytolites, and ooids similar to that found in numerous other Proterozoic carbonate successions; by sedimentary structures, including cross-beds and megaripples that characterize the pisolitic beds; and by microorganisms that inhabit modern marine ooids of the Bahama Banks. Petrographic features and strontium abundances suggest that the pisoids were originally aragonitic, but neomorphism, silicification, calcitization, and dolomitization have extensively modified original mineralogies and fabrics. The East Greenland and Svalbard pisolitic carbonates reflect similar depositional environments and diagenetic histories, reinforcing previous bio-, litho-, and chemostratigraphic interpretations that the two sequences accumulated contiguously in a coastal zone of pisoid genesis which extended for at least 600, and probably 1000 or more, kilometres.
Marine pisolites from Upper Proterozoic carbonates of East Greenland and Spitsbergen.
Swett, K; Knoll, A H
1989-01-01
Upper Proterozoic carbonate successions from central East Greenland (the Limestone-Dolomite 'Series' of the Eleonore Bay Group) and Svalbard (the Backlundtoppen Formation of the Akademikerbreen) Group, Spitsbergen, and the Upper Russo Formation of the Raoldtoppen Group, Nordaustlandet) contain thick sequences dominated by pisolites. These rocks were generated in shallow marine environments, and the pisoids are essentially oversized ooids. A marine environment is supported by the thickness and lateral extent of the carbonates; by a sedimentary association of pisolites with stromatolites, flake-conglomerates, calcarenites, calcilutites, microphytolites, and ooids similar to that found in numerous other Proterozoic carbonate successions; by sedimentary structures, including cross-beds and megaripples that characterize the pisolitic beds; and by microorganisms that inhabit modern marine ooids of the Bahama Banks. Petrographic features and strontium abundances suggest that the pisoids were originally aragonitic, but neomorphism, silicification, calcitization, and dolomitization have extensively modified original mineralogies and fabrics. The East Greenland and Svalbard pisolitic carbonates reflect similar depositional environments and diagenetic histories, reinforcing previous bio-, litho-, and chemostratigraphic interpretations that the two sequences accumulated contiguously in a coastal zone of pisoid genesis which extended for at least 600, and probably 1000 or more, kilometres.
Central fabrication: Carved positive assessment
Sanders, Joan E; Severance, Michael R; Myers, Timothy R; Ciol, Marcia A
2015-01-01
In this research we investigated the degree of error during the carving phase of central fabrication of prosthetic sockets for people with limb amputation. Three different model shapes were ordered from each of ten central fabrication companies. Using an accurate custom mechanical digitizer and alignment algorithm, we digitized the models and then compared the model shapes with the electronic file shapes. Results showed that 24 of the 30 models had volumes larger than the electronic file shapes while 24 had volumes that were smaller. 29 of the 30 models were oversized at the proximal aspect of the tibial tuberosity and undersized at the patellar tendon and popliteal areas. This error would result in a socket that had less tibial tubercle relief than intended in addition to a larger anterior-posterior dimension than desired. Comparison of the model shapes with socket shapes assessed for nine of the companies in a previous study showed that for five of the companies the sockets were relatively undersized over the tibial crest and fibular head. The results indicate that the socket the prosthetist receives will not always fit as planned, and that errors in the carving process are a source of the discrepancies. PMID:21515893
Bergeron, M.P.
1985-01-01
The Western New York Nuclear Service Center (WNYNSC) is a 3 ,336-acre tract of land in northern Cattaraugus County, NY, about 30 mi south of Buffalo. In 1963, 247 acres within the WNYNSC was developed for a nuclear-fuel reprocessing plant and ancillary facilities, including (1) a receiving and storage facility to store fuel prior to reprocessing, (2) underground storage tanks for liquid high-level radioactive wastes from fuel reprocessing, (3) a low-level wastewater treatment plant, and (4) two burial grounds for shallow burial of solid radioactive waste. A series of geologic and hydrologic investigations was done as part of the initial development and construction of the facilities by numerous agencies during 1960-62; these produced a large quantity of well data, some of which are difficult to locate or obtain. This report is a compilation of well and boring data collected during this period. The data include records of 236 wells, geologic logs of 145 wells and 167 test borings, and descriptions of 20 measured geologic sections. Two oversized maps show locations of the reported data. (USGS)
Fuel consumption impacts of auto roof racks
Chen, Yuche; Meier, Alan
2016-03-23
The after-market roof rack is one of the most common components attached to a vehicle for carrying over-sized items, such as bicycles and skis. It is important to understand these racks' fuel consumption impacts on both individual vehicles and the national fleet because they are widely used. We estimate the national fuel consumption impacts of roof racks using a bottom-up approach. Our model incorporates real-world data and vehicle stock information to enable assessing fuel consumption impacts for several categories of vehicles, rack configurations, and usage conditions. In addition, the model draws on two new data-gathering techniques, on-line forums and crowd-sourcing.more » The results show that nationwide, roof racks are responsible for 0.8‰ of light duty vehicle fuel consumption in 2015, corresponding to 100 million gallons of gasoline per year. Sensitivity analyses show that results are most sensitive to the fraction of vehicles with installed roof racks but carrying no equipment. Here, the aerodynamic efficiency of typical roof racks can be greatly improved and reduce individual vehicle fuel consumption; however, government policies to minimize extensive driving with empty racks--if successful--could save more fuel nationally.« less
Diffraction-based analysis of tunnel size for a scaled external occulter testbed
NASA Astrophysics Data System (ADS)
Sirbu, Dan; Kasdin, N. Jeremy; Vanderbei, Robert J.
2016-07-01
For performance verification of an external occulter mask (also called a starshade), scaled testbeds have been developed to measure the suppression of the occulter shadow in the pupil plane and contrast in the image plane. For occulter experiments the scaling is typically performed by maintaining an equivalent Fresnel number. The original Princeton occulter testbed was oversized with respect to both input beam and shadow propagation to limit any diffraction effects due to finite testbed enclosure edges; however, to operate at realistic space-mission equivalent Fresnel numbers an extended testbed is currently under construction. With the longer propagation distances involved, diffraction effects due to the edge of the tunnel must now be considered in the experiment design. Here, we present a diffraction-based model of two separate tunnel effects. First, we consider the effect of tunnel-edge induced diffraction ringing upstream from the occulter mask. Second, we consider the diffraction effect due to clipping of the output shadow by the tunnel downstream from the occulter mask. These calculations are performed for a representative point design relevant to the new Princeton occulter experiment, but we also present an analytical relation that can be used for other propagation distances.
Frost, Karen L; van Roosmalen, Linda; Bertocci, Gina; Cross, Douglas J
2012-01-01
An overview of the current status of wheelchair transportation safety in fixed route and demand-responsive, non-rail, public transportation vehicles within the US is presented. A description of each mode of transportation is provided, followed by a discussion of the primary issues affecting safety, accessibility, and usability. Technologies such as lifts, ramps, securement systems, and occupant restraint systems, along with regulations and voluntary industry standards have been implemented with the intent of improving safety and accessibility for individuals who travel while seated in their wheeled mobility device (e.g., wheelchair or scooter). However, across both fixed route and demand-responsive transit systems a myriad of factors such as nonuse and misuse of safety systems, oversized wheeled mobility devices, vehicle space constraints, and inadequate vehicle operator training may place wheeled mobility device (WhMD) users at risk of injury even under non-impact driving conditions. Since WhMD-related incidents also often occur during the boarding and alighting process, the frequency of these events, along with factors associated with these events are described for each transit mode. Recommendations for improving WhMD transportation are discussed given the current state of
Diffraction Effects in the SOFIA Telescope and Cavity Door
NASA Astrophysics Data System (ADS)
Erickson, E. F.; Haas, M. R.; Davis, P. K.
2005-12-01
Calculations of diffraction phenomena for SOFIA (the Stratospheric Observatory for Infrared Astronomy) are described. The analyses establish the diffraction-limited point-spread function for the planned central obscuration of the telescope, confirm the specification for the oversized primary mirror diameter, evaluate spider diffraction effects, and determine the variation in focal-plane flux with position of the telescope relative to the cavity door. The latter is a concern because motion between the door aperture and the telescope can vary the flux from a point source and the sky background by diffraction (even when the door aperture does not physically obstruct the geometrical beam). We find all these effects to be acceptable in terms of observatory performance, with the possible exception of fractional background variations 3E-3 at wavelengths 1mm. Fractional background variations larger than 1E-6 can exceed photon shot noise in one second for broad-band, background-limited infrared detectors systems. However, we expect that synchronous signal demodulation using the telescope's chopping secondary mirror will obviate this effect, assuming modulation of the diffracted sky radiation by the relative motion of the door and telescope occurs at frequencies well below the chopoper frequency. This work is supported by the National Aeronautics and Space Administration.
Estimation of aneurysm wall stresses created by treatment with a shape memory polymer foam device
Hwang, Wonjun; Volk, Brent L.; Akberali, Farida; Singhal, Pooja; Criscione, John C.
2012-01-01
In this study, compliant latex thin-walled aneurysm models are fabricated to investigate the effects of expansion of shape memory polymer foam. A simplified cylindrical model is selected for the in-vitro aneurysm, which is a simplification of a real, saccular aneurysm. The studies are performed by crimping shape memory polymer foams, originally 6 and 8 mm in diameter, and monitoring the resulting deformation when deployed into 4-mm-diameter thin-walled latex tubes. The deformations of the latex tubes are used as inputs to physical, analytical, and computational models to estimate the circumferential stresses. Using the results of the stress analysis in the latex aneurysm model, a computational model of the human aneurysm is developed by changing the geometry and material properties. The model is then used to predict the stresses that would develop in a human aneurysm. The experimental, simulation, and analytical results suggest that shape memory polymer foams have potential of being a safe treatment for intracranial saccular aneurysms. In particular, this work suggests oversized shape memory foams may be used to better fill the entire aneurysm cavity while generating stresses below the aneurysm wall breaking stresses. PMID:21901546
Rahman, Mokhlasur; Haberman, Adam; Tracy, Charles; Ray, Sanchali; Krämer, Helmut
2012-12-01
Chediak-Higashi syndrome (CHS) is a lethal disease caused by mutations that inactivate the lysosomal trafficking regulator protein (LYST). Patients suffer from diverse symptoms including oculocutaneous albinism, recurrent infections, neutropenia and progressive neurodegeneration. These defects have been traced back to over-sized lysosomes and lysosome-related organelles (LROs) in different cell types. Here, we explore mutants in the Drosophila mauve gene as a new model system for CHS. The mauve gene (CG42863) encodes a large BEACH domain protein of 3535 amino acids similar to LYST. This reflects a functional homology between these proteins as mauve mutants also display enlarged LROs, such as pigment granules. This Drosophila model also replicates the enhanced susceptibility to infections and we show a defect in the cellular immune response. Early stages of phagocytosis proceed normally in mauve mutant hemocytes but, unlike in wild type, late phagosomes fuse and generate large vacuoles containing many bacteria. Autophagy is similarly affected in mauve fat bodies as starvation-induced autophagosomes grow beyond their normal size. Together these data suggest a model in which Mauve functions to restrict homotypic fusion of different pre-lysosomal organelles and LROs. © 2012 John Wiley & Sons A/S.
Astronomical Alignments in a Neolithic Chinese Site?
NASA Astrophysics Data System (ADS)
Nelson, S.; Stencel, R. E.
1997-12-01
In the Manchurian province of Liaoning, near 41N19' and 119E30', exist ruins of a middle Neolithic society (2500 to 4000 BC) known as the Hongshan culture. This location, called Niuheliang, is comprised of 16 locations with monumental structures scattered over 80 square kilometers of hills. Most are stone burial structures that contain jade artifacts implying wealth and power. One structure is unique in being unusually shaped and containing oversized effigies of goddess figures. This structure also has a commanding view of the surrounding landscape. The presence of decorated pottery, jade and worked copper suggests the Hongshan people were sophisticated artisans and engaged in long-distance trading. During 1997, we've conducted a course at Denver as part of our Core Curriculum program for upper division students, that has examined the astronomical and cultural aspects of the Niuheliang site, to attempt to determine whether these contemporaries of the builders of Stonehenge may have included astronomical alignments into their constructions. The preliminary result of our studies suggests that certain monuments have potential for lunar standstill observation from the "goddess temple". For updates on these results, please see our website: www.du.edu/ rstencel/core2103.html.
Gillman, Ashley; Smith, Jye; Thomas, Paul; Rose, Stephen; Dowson, Nicholas
2017-12-01
Patient motion is an important consideration in modern PET image reconstruction. Advances in PET technology mean motion has an increasingly important influence on resulting image quality. Motion-induced artifacts can have adverse effects on clinical outcomes, including missed diagnoses and oversized radiotherapy treatment volumes. This review aims to summarize the wide variety of motion correction techniques available in PET and combined PET/CT and PET/MR, with a focus on the latter. A general framework for the motion correction of PET images is presented, consisting of acquisition, modeling, and correction stages. Methods for measuring, modeling, and correcting motion and associated artifacts, both in literature and commercially available, are presented, and their relative merits are contrasted. Identified limitations of current methods include modeling of aperiodic and/or unpredictable motion, attaining adequate temporal resolution for motion correction in dynamic kinetic modeling acquisitions, and maintaining availability of the MR in PET/MR scans for diagnostic acquisitions. Finally, avenues for future investigation are discussed, with a focus on improvements that could improve PET image quality, and that are practical in the clinical environment. © 2017 American Association of Physicists in Medicine.
Rain Fade Compensation Alternatives for Ka Band Communication Satellites
NASA Technical Reports Server (NTRS)
Acosta, Roberto J.
1997-01-01
Future satellite communications systems operating in Ka-band frequency band are subject to degradation produced by the troposphere which is much more severe than those found at lower frequency bands. These impairments include signal absorption by rain, clouds and gases, and amplitude scintillation's arising from refractive index irregularities. For example, rain attenuation at 20 GHz is almost three times that at 11 GHz. Although some of these impairments can be overcome by oversizing the ground station antennas and high power amplifiers, the current trend is using small (less than 20 inches apertures), low-cost ground stations (less than $1000) that can be easily deployed at user premises. As a consequence, most Ka-band systems are expected to employ different forms of fade mitigation that can be implemented relatively easily and at modest cost. The rain fade mitigation approaches are defined by three types of Ka-band communications systems - a low service rate (less than 1.5 Mb/s), a moderate service rate (1.5 to 6 Mb/s) system and a high service rate (greater than 43 Mb/s) system. The ACTS VSAT network, which includes an adaptive rain fade technique, is an example of a moderate service rate.
Thermal performance and heat transport in aquifer thermal energy storage
NASA Astrophysics Data System (ADS)
Sommer, W. T.; Doornenbal, P. J.; Drijver, B. C.; van Gaans, P. F. M.; Leusbrock, I.; Grotenhuis, J. T. C.; Rijnaarts, H. H. M.
2014-01-01
Aquifer thermal energy storage (ATES) is used for seasonal storage of large quantities of thermal energy. Due to the increasing demand for sustainable energy, the number of ATES systems has increased rapidly, which has raised questions on the effect of ATES systems on their surroundings as well as their thermal performance. Furthermore, the increasing density of systems generates concern regarding thermal interference between the wells of one system and between neighboring systems. An assessment is made of (1) the thermal storage performance, and (2) the heat transport around the wells of an existing ATES system in the Netherlands. Reconstruction of flow rates and injection and extraction temperatures from hourly logs of operational data from 2005 to 2012 show that the average thermal recovery is 82 % for cold storage and 68 % for heat storage. Subsurface heat transport is monitored using distributed temperature sensing. Although the measurements reveal unequal distribution of flow rate over different parts of the well screen and preferential flow due to aquifer heterogeneity, sufficient well spacing has avoided thermal interference. However, oversizing of well spacing may limit the number of systems that can be realized in an area and lower the potential of ATES.
Effects of Cabin Upsets on Adsorption Columns for Air Revitalization
NASA Technical Reports Server (NTRS)
LeVan, Douglas
1999-01-01
The National Aeronautics and Space Administration (NASA) utilizes adsorption technology as part of contaminant removal systems designed for long term missions. A variety of trace contaminants can be effectively removed from gas streams by adsorption onto activated carbon. An activated carbon adsorption column meets NASA's requirements of a lightweight and efficient means of controlling trace contaminant levels aboard spacecraft and space stations. The activated carbon bed is part of the Trace Contaminant Control System (TCCS) which is utilized to purify the cabin atmosphere. TCCS designs oversize the adsorption columns to account for irregular fluctuations in cabin atmospheric conditions. Variations in the cabin atmosphere include changes in contaminant concentrations, temperature, and relative humidity. Excessively large deviations from typical conditions can result from unusual crew activity, equipment malfunctions, or even fires. The research carried out under this award focussed in detail on the effects of cabin upsets on the performance of activated carbon adsorption columns. Both experiments and modeling were performed with an emphasis on the roll of a change in relative humidity on adsorption of trace contaminants. A flow through fixed-bed apparatus was constructed at the NASA Ames Research Center, and experiments were performed there. Modeling work was performed at the University of Virginia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simonen, Fredric A.; Gosselin, Stephen R.; Doctor, Steven R.
2013-04-22
This document describes a new method to determine whether the flaws in a particular reactor pressure vessel are consistent with the assumptions regarding the number and sizes of flaws used in the analyses that formed the technical justification basis for the new voluntary alternative Pressurized Thermal Shock (PTS) rule (Draft 10 CFR 50.61a). The new methodology addresses concerns regarding prior methodology because ASME Code Section XI examinations do not detect all fabrication flaws, they have higher detection performance for some flaw types, and there are flaw sizing errors always present (e.g., significant oversizing of small flaws and systematic under sizingmore » of larger flaws). The new methodology allows direct comparison of ASME Code Section XI examination results with values in the PTS draft rule Tables 2 and 3 in order to determine if the number and sizes of flaws detected by an ASME Code Section XI examination are consistent with those assumed in the probabilistic fracture mechanics calculations performed in support of the development of 10 CFR 50.61a.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zahradnik, R.
Science in Czechoslovakia suffered severely under successive periods of Nazi and communist domination. The system inherited by the current government was rigid and centralized. Scientists suffered throughout this period from poorly equipped laboratories, obsolete instruments, depressingly inadequate libraries, and negligible computer equipment. The university system has suffered so much - due to the lack of attention, incentive, resources, and prestige - that the training of young scientists has been greatly jeopardized. Nevertheless, although many of Czechoslovakia's research institutes are oversized, they also contain some excellent scientists - a tribute to the country's earlier heritage of excellent scientific and technical education.more » In the process of reforming the system, especially during this period of economic uncertainty, it is critical to support and preserve these pockets of excellence in order to make the most of any hopes of attaining Western' standards of living. Tight, multiple, wide contacts should be established between university and academy institutes. In this rebuilding effort, the universities have an extraordinarily important role. Czechoslovakia's recent efforts have shown some progress in this area. Yet much remains to be accomplished. Reforms must be carried out rapidly, given the time-lag before improvements will begin to bear fruit. 1 refs.« less
NASA Astrophysics Data System (ADS)
Rodriguez, J. F.; Gorrick, S.
2010-12-01
We present results of a riparian revegetation project on an oversized sand stream in eastern Australia. The Widden Brook in New South Wales has undergone extensive widening due to extraordinary floods in the 1950’s and is currently showing some signs of recovery. These include emergence of pool-riffle structure and stabilization of stream width, which are the result of upstream sediment control, riparian revegetation and livestock exclusion. Revegetation of a mild bend was carried out in 2004 using native plants in an arrangement that consisted of three vegetation patches. The same arrangement was tested in a reduced scale model in the laboratory, where extensive measurements of flow, sediment and bed changes provided insight into the links between hydrology, vegetation and geomorphology. Laboratory tests also included runs without vegetation and with a continuous vegetation cover. In terms of bank stability, the patches provided as much protection as the continuous vegetation. Based on the experiments, a series of analytical relationships were developed to help guide the design of vegetation patches focusing on the geomorphic stability of the whole reach instead of concentrating only on the near bank effects.
NASA Astrophysics Data System (ADS)
Mizuta, Kohei; Ohtaki, Michitaka
2016-03-01
We report the electrical and thermal properties of β-pyrochlore (defect pyrochlore) oxides AFe0.33W1.67O6 ( A = K, Rb, Cs) with a crystal structure having a small cation surrounded by oversized cage-like framework. The thermal conductivity, κ, of CsFe0.33W1.67O6 and RbFe0.33W1.67O6 showed extremely low values as oxides (below 1.0 W/mK) similar to those of ATaWO6 ( A = K, Rb, Cs) which we have already reported. These low κ values are ascribed to a "rattling" motion of the A cations, evidenced by their crystal structure refinement and the Raman spectra. Their electrical conductivity, σ, was in the order of 10-3 S/cm, and the Seebeck coefficient, S, was -500 to -600 μV/K. The electrical conductivity of AFe0.33W1.67O6 ( A = Rb, Cs) was much higher than those of ATaWO6 ( A = Rb, Cs), suggesting that an appropriate selection of the framework composition enables us to have better thermoelectric performance.
A photometric analysis of the neglected EW-type binary V336 TrA
NASA Astrophysics Data System (ADS)
Kriwattanawong, W.; Sarotsakulchai, T.; Maungkorn, S.; Reichart, D. E.; Haislip, J. B.; Kouprianov, V. V.; LaCluyze, A. P.; Moore, J. P.
2018-05-01
This study presents an analysis of photometric light curves and absolute parameters for the EW-type binary V336 TrA. VRI imaging observations were taken in 2013 by using the robotic telescopes PROMPT 4 and PROMPT 5 at Cerro Tololo Inter-American Observatory (CTIO), Chile. The observed light curves were fitted by using the Wilson-Devinney method. The results showed that V336 TrA is a W-type contact binary with a mass ratio of q = 1.396. The binary is a weak contact system with a fill-out factor of f = 15.69%. The system contains components with masses of 0.653 M⊙ and 0.912 M⊙ for the hotter and the cooler, respectively. The location of the secondary (less massive) component on the log M - log L diagram was found to be near the TAMS. The component has evolved to be oversize and overluminous. The orbital angular momentum of the binary was found to be log Jo = 51.61 cgs, less than all detached systems for same mass. The system has undergone angular momentum and/or mass loss, during the binary evolution from the detached to contact system.
Child health, nutrition and family size: a comparative study of rural and urban children.
Balderama-guzman, V
1978-01-01
771 children from Baras, Rizal, and Pasay City, Philippines were studied. House interviews of mothers using precoded questionnaires were conducted and the children were given a complete physical examination. The study objectives were to compare the health and nutritional status of children in a rural and an urban area in greater Manila and to determine how family size affects the nutritional status of children 3 years and younger. The following were among the study results: 1) the weight curves of both urban and rural groups were similar until age 4-1/2 years, but beyond this age the mean weight curve of the rural group exceeded that of the urban group; 2) urban children between ages 1-5 enjoyed a height advantage; 3) there was a positive correlation between malnutrition and excessive family size; 4) the high prevalence of malnutrition among children 1-4 years of age was due to food deprivation because of poverty, parental ignorance, inappropriate folklores, oversized families, high episodes of illnesses, and inadequate medical care; and 5) dietary assessment of both groups showed the inadequacy of the quality and quantity of basic nutrients and elements needed for growth, development, and repair of tissues.
Sampling of radical prostatectomy specimens. How much is adequate?
Cohen, M B; Soloway, M S; Murphy, W M
1994-03-01
Prostate glands from 52 patients with clinical stage B carcinoma were examined using two sampling techniques. After fixation and conization of the apical portions, each gland was serially sectioned with sections mounted whole on oversized glass slides and examined for pathologic features of prognostic importance. A second examination was subsequently conducted on the same tissue using only alternate sections. No differences in tumor type, grade, Gleason score, multiplicity, or capsular penetration were detected in 75% of cases. The discrepancies that did occur were most often minor variations in multiplicity and Gleason score. Of the 20 glands with capsular penetration observed with the serial sectioning method, 17 (85%) were detected using alternate sectioning. The surgical margin was involved in two of the three invasive foci that would have been missed. Although the topography is better displayed, the authors' examinations indicated no significant advantage to whole mount sections compared with sections mounted on standard-sized glass slides. Considering the most effective use of resources, as well as the current modalities available for patient monitoring, the results support the use of an alternate sectioning method for pathologic examination of specimens removed for clinically localized prostate cancer.
Computerized Machine for Cutting Space Shuttle Thermal Tiles
NASA Technical Reports Server (NTRS)
Ramirez, Luis E.; Reuter, Lisa A.
2009-01-01
A report presents the concept of a machine aboard the space shuttle that would cut oversized thermal-tile blanks to precise sizes and shapes needed to replace tiles that were damaged or lost during ascent to orbit. The machine would include a computer-controlled jigsaw enclosed in a clear acrylic shell that would prevent escape of cutting debris. A vacuum motor would collect the debris into a reservoir and would hold a tile blank securely in place. A database stored in the computer would contain the unique shape and dimensions of every tile. Once a broken or missing tile was identified, its identification number would be entered into the computer, wherein the cutting pattern associated with that number would be retrieved from the database. A tile blank would be locked into a crib in the machine, the shell would be closed (proximity sensors would prevent activation of the machine while the shell was open), and a "cut" command would be sent from the computer. A blade would be moved around the crib like a plotter, cutting the tile to the required size and shape. Once the tile was cut, an astronaut would take a space walk for installation.
Anabolic steroid usage in athletics: facts, fiction, and public relations.
Berning, Joseph M; Adams, Kent J; Stamford, Bryant A
2004-11-01
Anecdotal evidence suggests the widespread usage of anabolic steroids among athletes (20-90%), particularly at the professional and elite amateur levels. In contrast, scientific studies indicate that usage is rare and no higher than 6%. Conclusions from scientific studies suggest that anabolic steroid usage declines progressively from high school to college and beyond; however, anecdotal evidence claims the opposite trend. In this clash between "hard" scientific data vs. "soft" anecdotal information, it is natural that professionals would gravitate toward scientifically based conclusions. However, in the case of anabolic steroids (a stigmatized and illegal substance), should word-of-mouth testimony from individuals closest to the issues--those who have participated in and coached sports, those who have served as drug-testing overseers, and journalists who relentlessly track leads and verify sources--be set aside as irrelevant? Not if a complete picture is to emerge. In this review, hard scientific evidence is placed on the table side-by-side with soft anecdotal evidence, without weighting or bias. The purpose is to allow the opportunity for each to illuminate the other and, in so doing, potentially bring us a step closer to determining the true extent of anabolic steroid usage in athletics.
[Mechanisms and prevention of kitesurfing injuries].
Petersen, W; Hansen, U; Zernial, O; Nickel, C; Prymka, M
2002-09-01
Aim of this study was to analyse the mechanisms of kitesurfing injuries. For this purpose we performed a survey among 72 kitesurfers in the north of Germany. 31 accidents have been registrated among all 72 athletes during the 2001 season. 3 additional accidents occurred where a windsurfer got injured. 5 athletes had medium injuries such as fractures, all remaining athletes presented with minor injuries, that did not require medical treatment. The incidence of medium kite injuries was 1/1000 hours; the incidence of minor kite injuries was 5/1000 hours. The most common injury mechanism was a direct trauma against things such as stones and boats lying on the beach. The most common situation in which the injury occurred was the lost of control about the kite on the beach or close to the beach due to technical mistakes of the surfer, oversized kites, or the wind conditions (onshore wind, overpower). Further injuries occurred due to collisions with windsurfers or sailing boats. Kitesurfing is a new rapidly growing sport. To date the risk potential of this new sport is unclear. The analysis of the injury mechanisms allows conclusion regarding the prevention of kitesurfing injuries.
Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent). The original ventilation design for the project was provided by a local engineer and consisted of a single large heat recovery ventilator (HRV) located in a mechanical room in the basementmore » with a centralized duct system providing supply air to the main living space and exhausting stale air from the single bathroom in each apartment. This design was deemed to be far too costly to install and operate for several reasons: the large central HRV was oversized and the specified flows to each apartment were much higher than the ASHRAE 62.2 rate; an extensive system of ductwork, smoke and fire dampers, and duct chases were specified; ductwork required a significant area of dropped ceilings; and the system lacked individual ventilation control in the apartments« less
Coupling of emergent octahedral rotations to polarization in (K,Na)NbO3 ferroelectrics.
Levin, I; Krayzman, V; Cibin, G; Tucker, M G; Eremenko, M; Chapman, K; Paul, R L
2017-11-15
Perovskite potassium sodium niobates, K 1-x Na x NbO 3 , are promising lead-free piezoelectrics. Their dielectric and piezoelectric characteristics peak near x = 0.5, but the reasons for such property enhancement remain unclear. We addressed this uncertainty by analyzing changes in the local and average structures across the x = 0.5 composition, which have been determined using simultaneous Reverse Monte Carlo fitting of neutron and X-ray total-scattering data, potassium EXAFS, and diffuse-scattering patterns in electron diffraction. Within the A-sites, Na cations are found to be strongly off-centered along the polar axis as a result of oversized cube-octahedral cages determined by the larger K ions. These Na displacements promote off-centering of the neighboring Nb ions, so that the Curie temperature and spontaneous polarization remain largely unchanged with increasing x, despite the shrinking octahedral volumes. The enhancement of the properties near x = 0.5 is attributed to an abrupt increase in the magnitude and probability of the short-range ordered octahedral rotations, which resembles the pre-transition behavior. These rotations reduce the bond tension around Na and effectively soften the short Na-O bond along the polar axis - an effect that is proposed to facilitate reorientation of the polarization as external electric field is applied.
Thermal Management Architecture for Future Responsive Spacecraft
NASA Astrophysics Data System (ADS)
Bugby, D.; Zimbeck, W.; Kroliczek, E.
2009-03-01
This paper describes a novel thermal design architecture that enables satellites to be conceived, configured, launched, and operationally deployed very quickly. The architecture has been given the acronym SMARTS for Satellite Modular and Reconfigurable Thermal System and it involves four basic design rules: modest radiator oversizing, maximum external insulation, internal isothermalization and radiator heat flow modulation. The SMARTS philosophy is being developed in support of the DoD Operationally Responsive Space (ORS) initiative which seeks to drastically improve small satellite adaptability, deployability, and design flexibility. To illustrate the benefits of the philosophy for a prototypical multi-paneled small satellite, the paper describes a SMARTS thermal control system implementation that uses: panel-to-panel heat conduction, intra-panel heat pipe isothermalization, radiator heat flow modulation via a thermoelectric cooler (TEC) cold-biased loop heat pipe (LHP) and maximum external multi-layer insulation (MLI). Analyses are presented that compare the traditional "cold-biasing plus heater power" passive thermal design approach to the SMARTS approach. Plans for a 3-panel SMARTS thermal test bed are described. Ultimately, the goal is to incorporate SMARTS into the design of future ORS satellites, but it is also possible that some aspects of SMARTS technology could be used to improve the responsiveness of future NASA spacecraft. [22 CFR 125.4(b)(13) applicable
New receiving line for the remote-steering antenna of the 140 GHz CTS diagnostics in the FTU Tokamak
NASA Astrophysics Data System (ADS)
D'Arcangelo, O.; Bin, W.; Bruschi, A.; Cappelli, M.; Fanale, F.; Gittini, G.; Pallotta, F.; Rocchi, G.; Tudisco, O.; Garavaglia, S.; Granucci, G.; Moro, A.; Tuccillo, A. A.
2018-01-01
A new receiving antenna for collecting signals of the Collective Thomson Scattering (CTS) diagnostics in FTU Tokamak has been recently installed. The squared corrugated section and the precisely defined length make it possible to receive from different directions by remotely steering the receiving mirrors. This type of Remote-Steering (RS) antennas, being studied on FTU for the DEMO Electron Cyclotron Heating (ECH) system launch, is already installed on the W7- X stellarator and will be tested in the next campaign. The transmission of the signal from the antenna in the tokamak hall to the CTS diagnostics hall will be mainly realized by means of oversized circular corrugated waveguides carrying the hybrid HE11 (quasi-gaussian) waveguide mode, with inclusion of a special smooth-waveguide section and a short run of reduced-size square-corrugated waveguide through the tokamak bio-shield. The coupling between different waveguide types is made with ellipsoidal focusing mirrors, using quasi-optical matching formulas between the gaussian-shaped beams in input and output to the waveguides. In this work, after a complete study of feasibility of the overall line, a design for the receiving line will be proposed, in order to realize an executive layout to be used as a guideline for the commissioning phase.
Jantzen, Benjamin; Eisner, Thomas
2008-01-01
In Lepidoptera, forewings and hindwings are mechanically coupled and flap in synchrony. Flight is anteromotoric, being driven primarily by action of the forewings. Here we report that lepidopterans can still fly when their hindwings are cut off, a procedure reducing their total wing surface, on average, by nearly one half. However, as we demonstrate by analysis of three-dimensional flight trajectories of a moth and a butterfly (Lymantria dispar and Pieris rapae), hindwing removal causes lepidopterans to incur a loss in both linear and turning acceleration, so that they are unable to exercise their normal flight maneuverability. Without hindwings they still are able to zigzag aerially (the ablation has no effect on their turning radius in flight) but at lesser speed and therefore less evasively. Consequently, hindwings in the expanded state in which they occur in lepidopterans seem to contribute in an essential way to lepidopteran survival. Moths in today's world, we argue, may rely on their evasive flight primarily to avoid capture by bats, whereas butterflies, which we propose advertise their evasiveness collectively through shared aposematism, may depend upon it primarily for defense against birds. Aerial agility thus may be the chief adaptive asset derived by lepidopterans from possession of oversize hindwings. PMID:18936482
Use of geological mapping tools to improve the hydraulic performance of SuDS.
Bockhorn, Britta; Klint, Knud Erik Strøyberg; Jensen, Marina Bergen; Møller, Ingelise
2015-01-01
Most cities in Denmark are situated on low permeable clay rich deposits. These sediments are of glacial origin and range among the most heterogeneous, with hydraulic conductivities spanning several orders of magnitude. This heterogeneity has obvious consequences for the sizing of sustainable urban drainage systems (SuDS). We have tested methods to reveal geological heterogeneity at field scale to identify the most suitable sites for the placement of infiltration elements and to minimize their required size. We assessed the geological heterogeneity of a clay till plain in Eastern Jutland, Denmark measuring the shallow subsurface resistivity with a geoelectrical multi-electrode system. To confirm the resistivity data we conducted a spear auger mapping. The exposed sediments ranged from clay tills over sandy clay tills to sandy tills and correspond well to the geoelectrical data. To verify the value of geological information for placement of infiltration elements we carried out a number of infiltration tests on geologically different areas across the field, and we observed infiltration rates two times higher in the sandy till area than in the clay till area, thus demonstrating that the hydraulic performance of SuDS can be increased considerably and oversizing avoided if field geological heterogeneity is revealed before placing SuDS.
Nerve stress during reverse total shoulder arthroplasty: a cadaveric study.
Lenoir, Hubert; Dagneaux, Louis; Canovas, François; Waitzenegger, Thomas; Pham, Thuy Trang; Chammas, Michel
2017-02-01
Neurologic lesions are relatively common after total shoulder arthroplasty. These injuries are mostly due to traction. We aimed to identify the arm manipulations and steps during reverse total shoulder arthroplasty (RTSA) that affect nerve stress. Stress was measured in 10 shoulders of 5 cadavers by use of a tensiometer on each nerve from the brachial plexus, with shoulders in different arm positions and during different surgical steps of RTSA. When we studied shoulder position without prostheses, relative to the neutral position, internal rotation increased stress on the radial and axillary nerves and external rotation increased stress on the musculocutaneous, median, and ulnar nerves. Extension was correlated with increase in stress on all nerves. Abduction was correlated with increase in stress for the radial nerve. We identified 2 high-risk steps during RTSA: humeral exposition, particularly when the shoulder was in a position of more extension, and glenoid exposition. The thickness of polyethylene humeral cups used was associated with increased nerve stress in all but the ulnar nerve. During humeral preparation, the surgeon must be careful to limit shoulder extension. Care must be taken during exposure of the glenoid. Extreme rotation and oversized implants should be avoided to minimize stretch-induced neuropathies. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Lucà-Moretti, M; Grandi, A; Lucà, E; Muratori, G; Nofroni, M G; Mucci, M P; Gambetta, P; Stimolo, R; Drago, P; Giudice, G; Tamburlin, N
2003-01-01
Results of this multicentric study have shown that by giving 10 g (10 tablets) of Master Amino acid Pattern (MAP) as a substitute for dietary proteins, once a day, to 114 overweight participants undergoing the American Nutrition Clinics/Overweight Management Program (ANC/OMP), the participants' nitrogen balance could be maintained in equilibrium with essentially no calories (MAP 1 g=0.04 kcal), thereby preserving the body's structural and functional proteins, eliminating excessive water retention from the interstitial compartment, and preventing the sudden weight increase after study conclusion commonly known as the yo-yo effect. Study results have shown that the use of MAP, in conjunction with the ANC/OMP, has proven to be safe and effective by preventing those adverse effects associated with a negative nitrogen balance, such as oversized or flabby tissue, stretch marks, sagging of breast tissue, increased hair loss, faded hair color, and fragile or brittle nails. Also preventing those anomalies commonly associated with weight-loss diets, such as hunger, weakness, headache caused by ketosis, constipation, or decreased libido, the use of MAP, in conjunction with the ANC/OMP, allowed for mean weight loss of 1.4 kg (3 lb) per week.
Vortex formation with a snapping shrimp claw.
Hess, David; Brücker, Christoph; Hegner, Franziska; Balmert, Alexander; Bleckmann, Horst
2013-01-01
Snapping shrimp use one oversized claw to generate a cavitating high speed water jet for hunting, defence and communication. This work is an experimental investigation about the jet generation. Snapping shrimp (Alpheus-bellulus) were investigated by using an enlarged transparent model reproducing the closure of the snapper claw. Flow inside the model was studied using both High-Speed Particle Image Velocimetry (HS-PIV) and flow visualization. During claw closure a channel-like cavity was formed between the plunger and the socket featuring a nozzle-type contour at the orifice. Closing the mechanism led to the formation of a leading vortex ring with a dimensionless formation number of approximate ΔT*≈4. This indicates that the claw might work at maximum efficiency, i.e. maximum vortex strength was achieved by a minimum of fluid volume ejected. The subsequent vortex cavitation with the formation of an axial reentrant jet is a reasonable explanation for the large penetration depth of the water jet. That snapping shrimp can reach with their claw-induced flow. Within such a cavitation process, an axial reentrant jet is generated in the hollow cylindrical core of the cavitated vortex that pushes the front further downstream and whose length can exceed the initial jet penetration depth by several times.
Regional Studies of the Potwar Plateau Area, Northern Pakistan
Warwick, Peter D.; Wardlaw, Bruce R.
2007-01-01
The papers in this volume are products of a cooperative program between the Geological Survey of Pakistan (GSP) and the U.S. Geological Survey (USGS), sponsored by the Government of Pakistan and the U.S. Agency for International Development. The focus of the program, the Coal Resources Exploration and Assessment Program (COALREAP), was to explore and assess Pakistan?s indigenous coal resources. As part of COALREAP, GSP and USGS geologists conducted regional geologic studies from 1988 to 1991 of the coal-bearing areas in the Potwar region of northern Pakistan. A reference section was selected from which to obtain faunal and floral analyses. The composite sections at Nammal Pass and Nammal Dam served as the basis for this regional reference. Although this Bulletin 2078 is being released in 2007, the writing and technical reviews were completed in 1993, and the chapters reflect the work done until that time. During the long production process for the Bulletin, which ultimately resulted in the oversize plates being digitized, the scientific content of the chapters was not changed, and most reports published since 1993 were not cited. A change in the age of the Patala Formation is discussed below [in the full preface], but the age discussions and illustrations in the chapters were not updated.
NASA Astrophysics Data System (ADS)
Veprik, A.; Zechtzer, S.; Pundak, N.; Kirkconnell, C.; Freeman, J.; Riabzev, S.
2011-06-01
Cryogenic coolers are often used in modern spacecraft in conjunction with sensitive electronics and sensors of military, commercial and scientific instrumentation. The typical space requirements are: power efficiency, low vibration export, proven reliability, ability to survive launch vibration/shock and long-term exposure to space radiation. A long-standing paradigm of exclusively using "space heritage" equipment has become the standard practice for delivering high reliability components. Unfortunately, this conservative "space heritage" practice can result in using outdated, oversized, overweight and overpriced cryogenic coolers and is becoming increasingly unacceptable for space agencies now operating within tough monetary and time constraints. The recent trend in developing mini and micro satellites for relatively inexpensive missions has prompted attempts to adapt leading-edge tactical cryogenic coolers for suitability in the space environment. The primary emphasis has been on reducing cost, weight and size. The authors are disclosing theoretical and practical aspects of a collaborative effort to develop a space qualified cryogenic refrigerator system based on the tactical cooler model Ricor K527 and the Iris Technology radiation hardened Low Cost Cryocooler Electronics (LCCE). The K27/LCCE solution is ideal for applications where cost, size, weight, power consumption, vibration export, reliability and time to spacecraft integration are of concern.
What difference do brain images make in US criminal trials?
Hardcastle, Valerie Gray; Lamb, Edward
2018-05-09
One of the early concerns regarding the use of neuroscience data in criminal trials is that even if the brain images are ambiguous or inconclusive, they still might influence a jury in virtue of the fact that they appear easy to understand. By appearing visually simple, even though they are really statistically constructed maps with a host of assumptions built into them, a lay jury or a judge might take brain scans to be more reliable or relevant than they actually are. Should courts exclude brain scans for being more prejudicial than probative? Herein, we rehearse a brief history of brain scans admitted into criminal trials in the United States, then describe the results of a recent analysis of appellate court decisions that referenced 1 or more brain scans in the judicial decision. In particular, we aim to explain how courts use neuroscience imaging data: Do they interpret the data correctly? Does it seem that scans play an oversized role in judicial decision-making? And have they changed how criminal defendants are judged? It is our hope that in answering these questions, clinicians and defence attorneys will be able to make better informed decisions regarding about how to manage those incarcerated. © 2018 John Wiley & Sons, Ltd.
Atomic diffusion in strain fields near solutes
NASA Astrophysics Data System (ADS)
Shropshire, Steven L.; Collins, Gary S.
1993-03-01
Annihilation reactions between mobile self-interstitial defects and complexes of vacancies with111In probe solutes in Au were studied. Measurements were made using the technique of perturbed angular correlations of gamma rays (PAC). Au samples were doped with complexes and plastically deformed at a low temperature to generate fluxes of self-interstitials. Changes in the concentrations of monovacancy (1V) to tetravacancy (4V) complexes induced by annihilation reactions were measured. These are now analysed using a system of coupled first-order equations in order to obtain interstitial annihilation cross sections of the complexes and the fractional amounts of different interstitial clusters in the flux. Relative cross sections obtained for Au are 1.0(1), 3.3(3), 1.2(2) and 7.5(2.5), respectively, for 1V to 4V complexes. The large increase in the cross sections with vacancy number is attributed to a progressive relaxation of the dilatational strain surrounding the oversized In solute as more vacancies are trapped. Also obtained from the analysis are values 0.34(5), 0.66(7), 0.0(1) and 0.0(2), respectively, for the fractions of mobile 1I to 4I clusters in deformed Au, indicating that di-interstitials are produced more readily than mono-interstitials during plastic deformation.
Mechanical limits to maximum weapon size in a giant rhinoceros beetle.
McCullough, Erin L
2014-07-07
The horns of giant rhinoceros beetles are a classic example of the elaborate morphologies that can result from sexual selection. Theory predicts that sexual traits will evolve to be increasingly exaggerated until survival costs balance the reproductive benefits of further trait elaboration. In Trypoxylus dichotomus, long horns confer a competitive advantage to males, yet previous studies have found that they do not incur survival costs. It is therefore unlikely that horn size is limited by the theoretical cost-benefit equilibrium. However, males sometimes fight vigorously enough to break their horns, so mechanical limits may set an upper bound on horn size. Here, I tested this mechanical limit hypothesis by measuring safety factors across the full range of horn sizes. Safety factors were calculated as the ratio between the force required to break a horn and the maximum force exerted on a horn during a typical fight. I found that safety factors decrease with increasing horn length, indicating that the risk of breakage is indeed highest for the longest horns. Structural failure of oversized horns may therefore oppose the continued exaggeration of horn length driven by male-male competition and set a mechanical limit on the maximum size of rhinoceros beetle horns. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Broadband W-band Rapid Frequency Sweep Considerations for Fourier Transform EPR.
Strangeway, Robert A; Hyde, James S; Camenisch, Theodore G; Sidabras, Jason W; Mett, Richard R; Anderson, James R; Ratke, Joseph J; Subczynski, Witold K
2017-12-01
A multi-arm W-band (94 GHz) electron paramagnetic resonance spectrometer that incorporates a loop-gap resonator with high bandwidth is described. A goal of the instrumental development is detection of free induction decay following rapid sweep of the microwave frequency across the spectrum of a nitroxide radical at physiological temperature, which is expected to lead to a capability for Fourier transform electron paramagnetic resonance. Progress toward this goal is a theme of the paper. Because of the low Q-value of the loop-gap resonator, it was found necessary to develop a new type of automatic frequency control, which is described in an appendix. Path-length equalization, which is accomplished at the intermediate frequency of 59 GHz, is analyzed. A directional coupler is favored for separation of incident and reflected power between the bridge and the loop-gap resonator. Microwave leakage of this coupler is analyzed. An oversize waveguide with hyperbolic-cosine tapers couples the bridge to the loop-gap resonator, which results in reduced microwave power and signal loss. Benchmark sensitivity data are provided. The most extensive application of the instrument to date has been the measurement of T 1 values using pulse saturation recovery. An overview of that work is provided.
Lupini, A.R.; de Jonge, N.
2012-01-01
Aberration-correction reduces the depth of field in scanning transmission electron microscopy (STEM) and thus allows three-dimensional imaging by depth-sectioning. This imaging mode offers the potential for sub-Ångstrom lateral resolution and nanometer-scale depth sensitivity. For biological samples, which may be many microns across and where high lateral resolution may not always be needed, optimizing the depth resolution even at the expense of lateral resolution may be desired, aiming to image through thick specimens. Although there has been extensive work examining and optimizing the probe formation in two-dimensions, there is less known about the probe shape along the optical axis. Here the probe shape is examined in three-dimensions in an attempt to better understand the depth-resolution in this mode. Examples are presented of how aberrations change the probe shape in three-dimensions, and it is found that off-axial aberrations may need to be considered for focal series of large areas. It is shown that oversized or annular apertures theoretically improve the vertical resolution for 3D imaging of nanoparticles. When imaging nanoparticles of several nanometer size, regular STEM can thereby be optimized such that the vertical full width at half maximum approaches that of the aberration corrected STEM with a standard aperture. PMID:21878149
Identifying attentional bias and emotional response after appearance-related stimuli exposure.
Cho, Ara; Kwak, Soo-Min; Lee, Jang-Han
2013-01-01
The effect of media images has been regarded as a significant variable in the construction or in the activation of body images. Individuals who have a negative body image use avoidance coping strategies to minimize damage to their body image. We identified attentional biases and negative emotional responses following exposure to body stimuli. Female university students were divided into two groups based on their use of avoidance coping strategies (high-level group: high avoidance [HA]; low-group: low avoidance [LA]), and were assigned to two different conditions (exposure to thin body pictures, ET, and exposure to oversized body pictures, EO). Results showed that the HA group paid more attention to slim bodies and reported more negative emotions than the LA group, and that the EO had more negative effects than the ET. We suggest that HAs may attend more to slim bodies as a way of avoiding overweight bodies, influenced by social pressure, and in the search for a compensation of a positive emotional balance. However, attentional bias toward slim bodies can cause an upward comparison process, leading to increased body dissatisfaction, which is the main factor in the development of eating disorders (EDs). Therefore, altering avoidance coping strategies should be considered for people at risk of EDs.
Abdellah, A M; Balla, Q I
2013-11-15
Due to rapid urbanization in Khartoum State, Domestic Solid Waste (DSW) management remains the biggest obsession that recurrently attracts the attention of the concern authorities and stakeholders. As one of the seven localities comprised the state, the Sharg El Neel Locality was chosen to study the DSW management efficiency. The materials and methods employed in collection of data is a package of techniques, one of which was by conducting interviews using structured and unstructured questions mainly directed to appropriate persons i.e., householders and particular government employees directly engaged in DSW management operations. The main findings reached in this study were that local authorities lack the necessary capacities to handle the immense problems of DSW management. Shortages of funds, inadequate number of workers, lack of transport and facilities and weakness of attitudes of respondents found to be among factors hindering the DSW management. Accordingly, proper scheduled and timing, well-trained public health officers and sanitary overseers and strict sustainable program to controlling flies, rodents, cockroach and other disease vectors are essential to properly managing DSW. Otherwise, problems resulting from solid waste generation in the study area will be magnitudized and the surrounding environment will definitely be deteriorated.
Foladori, P; Vaccari, M; Vitali, F
2015-01-01
Energy audits in wastewater treatment plants (WWTPs) reveal large differences in the energy consumption in the various stages, depending also on the indicators used in the audits. This work is aimed at formulating a suitable methodology to perform audits in WWTPs and identifying the most suitable key energy consumption indicators for comparison among different plants and benchmarking. Hydraulic-based stages, stages based on chemical oxygen demand, sludge-based stages and building stages were distinguished in WWTPs and analysed with different energy indicators. Detailed energy audits were carried out on five small WWTPs treating less than 10,000 population equivalent and using continuous data for 2 years. The plants have in common a low designed capacity utilization (52% on average) and equipment oversizing which leads to waste of energy in the absence of controls and inverters (a common situation in small plants). The study confirms that there are several opportunities for reducing energy consumption in small WWTPs: in addition to the pumping of influent wastewater and aeration, small plants demonstrate low energy efficiency in recirculation of settled sludge and in aerobic stabilization. Denitrification above 75% is ensured through intermittent aeration and without recirculation of mixed liquor. Automation in place of manual controls is mandatory in illumination and electrical heating.
A canine model of tracheal stenosis induced by cuffed endotracheal intubation
Su, Zhuquan; Li, Shiyue; Zhou, Ziqing; Chen, Xiaobo; Gu, Yingying; Chen, Yu; Zhong, Changhao; Zhong, Minglu; Zhong, Nanshan
2017-01-01
Postintubation tracheal stenosis is a complication of endotracheal intubation. The pathological mechanism and risk factors for endotracheal intubation-induced tracheal stenosis remain not fully understood. We aimed to establish an animal model and to investigate risk factors for postintubation tracheal stenosis. Beagles were intubated with 4 sized tubes (internal diameter 6.5 to 8.0 mm) and cuff pressures of 100 to 200 mmHg for 24 hr. The status of tracheal wall was evaluated by bronchoscopic and histological examinations. The model was successfully established by cuffed endotracheal intubation using an 8.0 mm tube and an intra-cuff pressure of 200 mmHg for 24 hr. When the intra-cuff pressures were kept constant, a larger sized tube would induce a larger tracheal wall pressure and more severe injury to the tracheal wall. The degree of tracheal stenosis ranged from 78% to 91% at 2 weeks postextubation. Histological examination demonstrated submucosal infiltration of inflammatory cells, hyperplasia of granulation tissue and collapse of tracheal cartilage. In summary, a novel animal model of tracheal stenosis was established by cuffed endotracheal intubation, whose histopathological feathers are similar to those of clinical cases of postintubation tracheal stenosis. Excessive cuff pressure and over-sized tube are the risk factors for postintubation tracheal stenosis. PMID:28349955
Variable Threshold Method for Determining the Boundaries of Imaged Subvisible Particles.
Cavicchi, Richard E; Collett, Cayla; Telikepalli, Srivalli; Hu, Zhishang; Carrier, Michael; Ripple, Dean C
2017-06-01
An accurate assessment of particle characteristics and concentrations in pharmaceutical products by flow imaging requires accurate particle sizing and morphological analysis. Analysis of images begins with the definition of particle boundaries. Commonly a single threshold defines the level for a pixel in the image to be included in the detection of particles, but depending on the threshold level, this results in either missing translucent particles or oversizing of less transparent particles due to the halos and gradients in intensity near the particle boundaries. We have developed an imaging analysis algorithm that sets the threshold for a particle based on the maximum gray value of the particle. We show that this results in tighter boundaries for particles with high contrast, while conserving the number of highly translucent particles detected. The method is implemented as a plugin for FIJI, an open-source image analysis software. The method is tested for calibration beads in water and glycerol/water solutions, a suspension of microfabricated rods, and stir-stressed aggregates made from IgG. The result is that appropriate thresholds are automatically set for solutions with a range of particle properties, and that improved boundaries will allow for more accurate sizing results and potentially improved particle classification studies. Published by Elsevier Inc.
El Shahawy, Maha; Reibring, Claes-Göran; Neben, Cynthia L; Hallberg, Kristina; Marangoni, Pauline; Harfe, Brian D; Klein, Ophir D; Linde, Anders; Gritli-Linde, Amel
2017-07-01
The interaction between signaling pathways is a central question in the study of organogenesis. Using the developing murine tongue as a model, we uncovered unknown relationships between Sonic hedgehog (SHH) and retinoic acid (RA) signaling. Genetic loss of SHH signaling leads to enhanced RA activity subsequent to loss of SHH-dependent expression of Cyp26a1 and Cyp26c1. This causes a cell identity switch, prompting the epithelium of the tongue to form heterotopic minor salivary glands and to overproduce oversized taste buds. At developmental stages during which Wnt10b expression normally ceases and Shh becomes confined to taste bud cells, loss of SHH inputs causes the lingual epithelium to undergo an ectopic and anachronic expression of Shh and Wnt10b in the basal layer, specifying de novo taste placode induction. Surprisingly, in the absence of SHH signaling, lingual epithelial cells adopted a Merkel cell fate, but this was not caused by enhanced RA signaling. We show that RA promotes, whereas SHH, acting strictly within the lingual epithelium, inhibits taste placode and lingual gland formation by thwarting RA activity. These findings reveal key functions for SHH and RA in cell fate specification in the lingual epithelium and aid in deciphering the molecular mechanisms that assign cell identity.
Hruschka, Veronika; Tangl, Stefan; Ryabenkova, Yulia; Heimel, Patrick; Barnewitz, Dirk; Möbus, Günter; Keibl, Claudia; Ferguson, James; Quadros, Paulo; Miller, Cheryl; Goodchild, Rebecca; Austin, Wayne; Redl, Heinz; Nau, Thomas
2017-01-01
Nanocrystalline hydroxyapatite (HA) has good biocompatibility and the potential to support bone formation. It represents a promising alternative to autologous bone grafting, which is considered the current gold standard for the treatment of low weight bearing bone defects. The purpose of this study was to compare three bone substitute pastes of different HA content and particle size with autologous bone and empty defects, at two time points (6 and 12 months) in an ovine scapula drillhole model using micro-CT, histology and histomorphometry evaluation. The nHA-LC (38% HA content) paste supported bone formation with a high defect bridging-rate. Compared to nHA-LC, Ostim® (35% HA content) showed less and smaller particle agglomerates but also a reduced defect bridging-rate due to its fast degradation The highly concentrated nHA-HC paste (48% HA content) formed oversized particle agglomerates which supported the defect bridging but left little space for bone formation in the defect site. Interestingly, the gold standard treatment of the defect site with autologous bone tissue did not improve bone formation or defect bridging compared to the empty control. We concluded that the material resorption and bone formation was highly impacted by the particle-specific agglomeration behaviour in this study. PMID:28233833
Mechanical properties of different airway stents.
Ratnovsky, Anat; Regev, Noa; Wald, Shaily; Kramer, Mordechai; Naftali, Sara
2015-04-01
Airway stents improve pulmonary function and quality of life in patients suffering from airway obstruction. The aim of this study was to compare main types of stents (silicone, balloon-dilated metal, self-expanding metal, and covered self-expanding metal) in terms of their mechanical properties and the radial forces they exert on the trachea. Mechanical measurements were carried out using a force gauge and specially designed adaptors fabricated in our lab. Numerical simulations were performed for eight different stent geometries, inserted into trachea models. The results show a clear correlation between stent diameter (oversizing) and the levels of stress it exerts on the trachea. Compared with uncovered metal stents, metal stents that are covered with less stiff material exert significantly less stress on the trachea while still maintaining strong contact with it. The use of such stents may reduce formation of mucosa necrosis and fistulas while still preventing stent migration. Silicone stents produce the lowest levels of stress, which may be due to weak contact between the stent and the trachea and can explain their propensity for migration. Unexpectedly, stents made of the same materials exerted different stresses due to differences in their structure. Stenosis significantly increases stress levels in all stents. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kolb, Thomas; Fuchs, Markus; Zöller, Ludwig
2015-04-01
River terraces are widespread geomorphic features of Quaternary landscapes. Besides tectonics, their formation is predominantly controlled by climatic conditions. Changes in either conditions cause changes in fluvial discharge and sediment load. Therefore, fluvial terraces are widely used as important non-continuous sedimentary archives for paleotectonic and paleoenvironmental reconstruction. The informative value of fluvial archives and their significance for paleoenvironmental research, however, strongly depend on a precise dating of the terrace formation. Over the last decades, various luminescence dating techniques have successfully been applied on fluvial deposits and were able to provide reliable age information. In contrast to radiocarbon dating, modern luminescence dating techniques provide an extended dating range, which enables the determination of age information for fluvial and other terrestrial archives far beyond the last glacial-interglacial cycle. Due to the general abundance of quartz and feldspar minerals, there is almost no limitation of dateable material, so that luminescence dating methods can be applied on a wide variety of deposits. When using luminescence dating techniques, however, some methodological difficulties have to be considered. Due to the mechanism of fluvial transport, this is especially true for fluvial sediments, for which two major problems have been identified to be the main reasons of incorrect age estimations: (1) incomplete resetting of the luminescence signal during transport and (2) dosimetric inaccuracies as a result of the heterogeneity of terrace gravels. Thus, luminescence dating techniques are still far from being standard methods for dating fluvial archives and the calculated sedimentation ages always demand a careful interpretation. This contribution reveals some of the difficulties that may occur when luminescence dating techniques are applied on river terraces and illustrates several strategies used for overcoming these problems and for determining correct sedimentation ages. The presented results are based on a case study, located in the headwaters of the River Main, the longest right bank tributary of the Rhine drainage system. Here, within an oversized dry valley in Northern Bavaria (Germany), five Pleistocene terraces are distinguished. The terraces are interpreted as the result of a complex landscape evolution, which is characterized by multiple river deflections. The need for a careful interpretation of luminescence results is illustrated by some optically stimulated luminescence (OSL) ages calculated for the youngest of these five Pleistocene terraces. These results show different sedimentation ages of samples originating from the same morphological unit. Thus, these ages may be interpreted as evidence for a diachronic character of river incision and, hence, point to the complexity of fluvial systems' response to climatically and/or tectonically forced changes in local and regional paleoenvironmental conditions.
Data mining of space heating system performance in affordable housing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Xiaoxin; Yan, Da; Hong, Tianzhen
The space heating in residential buildings accounts for a considerable amount of the primary energy use. Therefore, understanding the operation and performance of space heating systems becomes crucial in improving occupant comfort while reducing energy use. This study investigated the behavior of occupants adjusting their thermostat settings and heating system operations in a 62-unit affordable housing complex in Revere, Massachusetts, USA. The data mining methods, including clustering approach and decision trees, were used to ascertain occupant behavior patterns. Data tabulating ON/OFF space heating states was assessed, to provide a better understanding of the intermittent operation of space heating systems inmore » terms of system cycling frequency and the duration of each operation. The decision tree was used to verify the link between room temperature settings, house and heating system characteristics and the heating energy use. The results suggest that the majority of apartments show fairly constant room temperature profiles with limited variations during a day or between weekday and weekend. Data clustering results revealed six typical patterns of room temperature profiles during the heating season. Space heating systems cycled more frequently than anticipated due to a tight range of room thermostat settings and potentially oversized heating capacities. In conclusion, from this study affirm data mining techniques are an effective method to analyze large datasets and extract hidden patterns to inform design and improve operations.« less
Effects of Socket Size on Metrics of Socket Fit in Trans-Tibial Prosthesis Users
Sanders, Joan E; Youngblood, Robert T; Hafner, Brian J; Cagle, John C; McLean, Jake B; Redd, Christian B; Dietrich, Colin R; Ciol, Marcia A; Allyn, Katheryn J
2017-01-01
The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8 mm (~6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4wk. Participants’ gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measure as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort scores, and self-reported measures of utility, satisfaction, and residual limb health. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study. PMID:28373013
Systems Analysis and Structural Design of an Unpressurized Cargo Delivery Vehicle
NASA Technical Reports Server (NTRS)
Wu, K. Chauncey; Cruz, Jonathan N.; Antol, Jeffrey; Sasamoto, Washito A.
2007-01-01
The International Space Station will require a continuous supply of replacement parts for ongoing maintenance and repair after the planned retirement of the Space Shuttle in 2010. These parts are existing line-replaceable items collectively called Orbital Replacement Units, and include heavy and oversized items such as Control Moment Gyroscopes and stowed radiator arrays originally intended for delivery aboard the Space Shuttle. Current resupply spacecraft have limited to no capability to deliver these external logistics. In support of NASA's Exploration Systems Architecture Study, a team at Langley Research Center designed an Unpressurized Cargo Delivery Vehicle to deliver bulk cargo to the Space Station. The Unpressurized Cargo Delivery Vehicle was required to deliver at least 13,200 lbs of cargo mounted on at least 18 Flight Releasable Attachment Mechanisms. The Crew Launch Vehicle design recommended in the Exploration Systems Architecture Study would be used to launch one annual resupply flight to the International Space Station. The baseline vehicle design developed here has a cargo capacity of 16,000 lbs mounted on up to 20 Flight Releasable Attachment Mechanisms. Major vehicle components are a 5.5m-diameter cargo module containing two detachable cargo pallets with the payload, a Service Module to provide propulsion and power, and an aerodynamic nose cone. To reduce cost and risk, the Service Module is identical to the one used for the Crew Exploration Vehicle design.
Data mining of space heating system performance in affordable housing
Ren, Xiaoxin; Yan, Da; Hong, Tianzhen
2015-02-16
The space heating in residential buildings accounts for a considerable amount of the primary energy use. Therefore, understanding the operation and performance of space heating systems becomes crucial in improving occupant comfort while reducing energy use. This study investigated the behavior of occupants adjusting their thermostat settings and heating system operations in a 62-unit affordable housing complex in Revere, Massachusetts, USA. The data mining methods, including clustering approach and decision trees, were used to ascertain occupant behavior patterns. Data tabulating ON/OFF space heating states was assessed, to provide a better understanding of the intermittent operation of space heating systems inmore » terms of system cycling frequency and the duration of each operation. The decision tree was used to verify the link between room temperature settings, house and heating system characteristics and the heating energy use. The results suggest that the majority of apartments show fairly constant room temperature profiles with limited variations during a day or between weekday and weekend. Data clustering results revealed six typical patterns of room temperature profiles during the heating season. Space heating systems cycled more frequently than anticipated due to a tight range of room thermostat settings and potentially oversized heating capacities. In conclusion, from this study affirm data mining techniques are an effective method to analyze large datasets and extract hidden patterns to inform design and improve operations.« less
Complex inguinal hernia repairs.
Beitler, J C; Gomes, S M; Coelho, A C J; Manso, J E F
2009-02-01
Complex inguinal hernia treatment is a challenge for general surgeons. The gold standard for the repair of inguinal hernias is the Lichtenstein repair (anterior approach). However, when multiple recurrent hernias or giant hernias are present, it is necessary to choose different approaches because the incidence of poor results increases. There are many preperitoneal approaches described in the literature. For example: (a) open procedure-Nyhus and Stoppa (b) laparoscopic technique-transabdominal pre-peritoneal (TAPP) and totally extraperitoneal (TEP). In this study, we show how we repair complicated cases using open access in huge unilateral or bilateral, recurrent, or multiple recurrent inguinal hernias. The present study includes the period from November 1993 through December 2007. One hundred and eighty-eight patients, divided into 121 with unilateral hernias and 67 with bilateral hernias, totaling 255 inguinal hernia repairs, were treated by the Nyhus or Stoppa preperitoneal approach, depending on whether they were unilateral or bilateral. We used progressive preoperative pneumoperitoneum for oversize inguinal hernias in all patients. Orchiectomy was necessary on only two occasions. Despite the repair complexity involved, we had only two known recurrences. The mortality was zero and the morbidity was acceptable. We conclude that an accurate open preperitoneal approach using mesh prosthesis for complex inguinal hernias is safe, with very low recurrent rates and low morbidity. Progressive preoperative pneumoperitoneum for giant hernias was shown to be an important factor in accomplishing good intraoperative and immediate postoperative results.
How do fission yeast cells grow and connect growth to the mitotic cycle?
Sveiczer, Ákos; Horváth, Anna
2017-05-01
To maintain size homeostasis in a unicellular culture, cells should coordinate growth to the division cycle. This is achieved via size control mechanisms (also known as size checkpoints), i.e. some events during the mitotic cycle supervene only if the cell has reached a critical size. Rod-shaped cells like those of fission yeast are ideal model organisms to study these checkpoints via time-lapse microphotography. By applying this method, once we can analyse the growth process between two consecutive divisions at a single (or even at an 'average') cellular level, moreover, we can also position the size checkpoint(s) at the population level. Finally, any of these controls can be abolished in appropriate cell cycle mutants, either in steady-state or in induction synchronised cultures. In the latter case, we produce abnormally oversized cells, and microscopic experiments with them clearly show the existence of a critical size above which the size checkpoint ceases (becomes cryptic). In this review, we delineate the development of our knowledge both on the growth mode of fission yeast and on the operating size control(s) during its mitotic cycle. We finish these historical stories with our recent findings, arguing that three different size checkpoints exist in the fission yeast cell cycle, namely in late G1, in mid G2 and in late G2, which has been concluded by analysing these controls in several cell cycle mutants.
Guan, Mingzhi; Wang, Xingzhe; Zhou, Youhe
2015-01-01
During design and winding of superconducting magnets at room temperature, a pre-tension under different rate is always applied to improve the mechanical stability of the magnets. However, an inconsistency rises for superconductors usually being sensitive to strain and oversized pre-stress which results in degradation of the superconducting composites' critical performance at low temperature. The present study focused on the effects of the cold-treatment and strain-rate of tension deformation on mechanical properties of NbTi/Cu superconducting composite wires. The samples were immersed in a liquid nitrogen (LN2) cryostat for the adiabatic cold-treatment, respectively with 18-hour, 20-hour, 22-hour and 24-hour. A universal testing machine was utilized for tension tests of the NbTi/Cu superconducting composite wires at room temperature; a small-scale extensometer was used to measure strain of samples with variable strain-rate. The strength, elongation at fracture and yield strength of pre-cold-treatment NbTi/Cu composite wires were drawn. It was shown that, the mechanical properties of the superconducting wires are linearly dependent on the holding time of cold-treatment at lower tensile strain-rate, while they exhibit notable nonlinear features at higher strain-rate. The cold-treatment in advance and the strain-rate of pre-tension demonstrate remarkable influences on the mechanical property of the superconducting composite wires.
Effects of socket size on metrics of socket fit in trans-tibial prosthesis users.
Sanders, Joan E; Youngblood, Robert T; Hafner, Brian J; Cagle, John C; McLean, Jake B; Redd, Christian B; Dietrich, Colin R; Ciol, Marcia A; Allyn, Katheryn J
2017-06-01
The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8mm (∼6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4 weeks. Participants' gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measured as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort score, and self-reported utility. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Improving the performance of surgery-based clinical pathways: a simulation-optimization approach.
Ozcan, Yasar A; Tànfani, Elena; Testi, Angela
2017-03-01
This paper aims to improve the performance of clinical processes using clinical pathways (CPs). The specific goal of this research is to develop a decision support tool, based on a simulation-optimization approach, which identify the proper adjustment and alignment of resources to achieve better performance for both the patients and the health-care facility. When multiple perspectives are present in a decision problem, critical issues arise and often require the balancing of goals. In our approach, meeting patients' clinical needs in a timely manner, and to avoid worsening of clinical conditions, we assess the level of appropriate resources. The simulation-optimization model seeks and evaluates alternative resource configurations aimed at balancing the two main objectives-meeting patient needs and optimal utilization of beds and operating rooms.Using primary data collected at a Department of Surgery of a public hospital located in Genoa, Italy. The simulation-optimization modelling approach in this study has been applied to evaluate the thyroid surgical treatment together with the other surgery-based CPs. The low rate of bed utilization and the long elective waiting lists of the specialty under study indicates that the wards were oversized while the operating room capacity was the bottleneck of the system. The model enables hospital managers determine which objective has to be given priority, as well as the corresponding opportunity costs.
Wong, J Y W; Buchholz, H; Ryerson, L; Conradi, A; Adatia, I; Dyck, J; Rebeyka, I; Lien, D; Mullen, J
2015-08-01
Lung transplantation (LTx) may be denied for children on extracorporeal membrane oxygenation (ECMO) due to high risk of cerebral hemorrhage. Rarely has successful LTx been reported in children over 10 years of age receiving awake or ambulatory veno-venous ECMO. LTx following support with ambulatory veno-arterial ECMO (VA ECMO) in children has never been reported to our knowledge. We present the case of a 4-year-old, 12-kg child with heritable pulmonary artery hypertension and refractory right ventricular failure. She was successfully bridged to heart-lung transplantation (HLTx) using ambulatory VA ECMO. Initial resuscitation with standard VA ECMO was converted to an ambulatory circuit using Berlin heart cannulae. She was extubated and ambulating around her bed while on VA ECMO for 40 days. She received an HLTx from an oversized marginal lung donor. Despite a cardiac arrest and Grade 3 primary graft dysfunction, she made a full recovery without neurological deficits. She achieved 104% force expiratory volume in 1 s 33 months post-HLTx. Ambulatory VA ECMO may be a useful strategy to bridge very young children to LTx or HLTx. Patient tailored ECMO cannulation, minimization of hemorrhage, and thrombosis risks while on ECMO contributed to a successful HLTx in our patient. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.
Lucà-Moretti, M; Grandi, A; Lucà, E; Muratori, G; Nofroni, M G; Mucci, M P; Gambetta, P; Stimolo, R; Drago, P; Giudice, G; Tamburlin, N; Karbalai, M; Valente, C; Moras, G
2003-01-01
Results of this multicentric study have shown that by giving Master Amino acid Pattern (MAP) as a sole and total substitute of dietary proteins to 500 overweight participants undergoing the American Nutrition Clinics/Overweight Management Program (ANC/OMP), the participants' body nitrogen balance could be maintained in equilibrium with essentially no calories (MAP 1 g=0.04 kcal), thereby preserving the body's structural and functional proteins, eliminating excessive water retention from the interstitial compartment, and preventing the sudden weight increase after study conclusion commonly known as the yo-yo effect. Study results have shown that the use of MAP, in conjunction with the ANC/OMP regimen, has proven to be safe and effective by preventing those adverse effects associated with a negative nitrogen balance, such as oversized or flabby tissue, stretch marks, the sagging of breast tissue, increased hair loss, faded hair color, and fragile or brittle nails. Also prevented were those anomalies commonly associated with weight-loss diets, such as hunger, weakness, headache caused by ketosis, constipation, and decreased libido. The use of MAP in conjunction with the ANC/OMP also allowed for mean weight loss of 2.5 kg (5.5 lb) per week, achieved through reduction of excessive fat tissue and elimination of excessive water retention from the interstitial compartment.
Performing the good death: the medieval Ars moriendi and contemporary doctors.
Thornton, K; Phillips, C B
2009-12-01
Death is inevitable, but dying well is not. Despite the role of medical professionals as overseers of dying in contemporary society, there is comparatively little discourse among doctors about the constituents of a good death. In the 15th century, by contrast, the Ars moriendi portrayed normative medieval ideas about good and bad deaths. At a time when dying could be viewed as a performed battle against damnation, the Ars moriendi codified a set of moral precepts that governed the expression of autonomy, relations between the dying and the living and orientation towards God. In these images, dying well is a moral activity that results from active decisions by the dying person to turn from earthly preoccupations to contemplation of, and submission to, the divine. It is likely in contemporary society that there is a range of understandings of the "good death". While attitudes to personal autonomy may differ, reflectiveness and dying at home in the presence of family (expressed in the Ars moriendi), remain part of many modern notions of the good death. We argue that medical institutions continue to construct death as a performed battle against physical debility, even when patients may have different views of their preferred deaths. The dialectic approach of the Ars moriendi may offer a way for contemporary doctors to reflect critically on the potential dissonance between their own approach to death and the variety of culturally valorised "good deaths".
Press-fit acetabular cup fixation: principles and testing.
Macdonald, W; Carlsson, L V; Charnley, G J; Jacobsson, C M
1999-01-01
Pre-clinical testing of the fixation of press-fit acetabular components of total hip prostheses relies on cadaver or synthetic bone, but the properties and geometry of bone models differ from those of physiological bone. Cup designs use varied mechanisms for initial stability in bone; therefore, using different analogues and tests is appropriate. Press-fit cup stability was tested in the following: firstly, polyurethane (PU) foam modelling cancellous support; secondly, glass-fibre reinforced epoxide (GFRE) tubes modelling acetabular cortical support; thirdly, cadaveric acetabula. Three commercial cups [Harris-Galante II (H-G-II), Zimmer; Optifix, Smith & Nephew, Richards; porous coated anatomic (PCA), Howmedica] and an experimental cup with enhanced rim fixation were tested in three modes: direct pull-out, lever-out and axial torque. The fixation stabilities measured in the PU and the GFRE models showed trends consistent with those in cadaver bone, differing in the oversizing and cup geometry. The experimental cup was significantly more secure in most modes than other cups; the H-G II and Optifix cups showed similar stabilities, lower than that of the experimental cup but greater than that of the PCA cup (analysis of variance and Tukey's highly significant test; p < 0.001). The stabilities measured in cadaver bone more closely approximated those in GFRE. The use of several bone analogues enables separation of fixation mechanisms, allowing more accurate prediction of in vivo performance.
Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy
NASA Technical Reports Server (NTRS)
Newman, Kevin; Belikov, Ruslan; Pluzhnik, Eugene; Balasubramanian, Kunjithapatham; Wilson, Dan
2014-01-01
Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.
Li, Jiachen; Pu, Jun; Liu, Ziqiang; Wang, Jian; Wu, Wenlu; Zhang, Huigang; Ma, Haixia
2017-08-02
The energy and power densities of rechargeable batteries urgently need to be increased to meet the ever-increasing demands of consumer electronics and electric vehicles. Alloy anodes are among the most promising candidates for next-generation high-capacity battery materials. However, the high capacities of alloy anodes usually suffer from some serious difficulties related to the volume changes of active materials. Porous supports and nanostructured alloy materials have been explored to address these issues. However, these approaches seemingly increase the active material-based properties and actually decrease the electrode-based capacity because of the oversized pores and heavy mass of mechanical supports. In this study, we developed an ultralight porous nickel to scaffold with high-capacity SnSb alloy anodes. The porous-nickel-supported SnSb alloy demonstrates a high specific capacity and good cyclability for both Li-ion and Na-ion batteries. Its capacity retains 580 mA h g -1 at 2 A g -1 after 100 cycles in Li-ion batteries. For a Na-ion battery, the composite electrode can even deliver a capacity of 275 mA h g -1 at 1 A g -1 after 1000 cycles. This study demonstrates that combining the scaffolding function of ultralight porous nickel and the high capacity of the SnSb alloy can significantly enhance the electrochemical performances of Li/Na-ion batteries.
Danczak, Robert E.; Sawyer, Audrey H.; Williams, Kenneth H.; ...
2016-12-03
Riverbed microbial communities play an oversized role in many watershed ecosystem functions, including the processing of organic carbon, cycling of nitrogen, and alterations to metal mobility. The structure and activity of microbial assemblages depend in part on geochemical conditions set by river-groundwater exchange or hyporheic exchange. In order to assess how seasonal changes in river-groundwater mixing affect these populations in a snowmelt-dominated fluvial system, vertical sediment and pore water profiles were sampled at three time points at one location in the hyporheic zone of the Colorado River and analyzed by using geochemical measurements, 16S rRNA gene sequencing, and ecological modeling.more » Oxic river water penetrated deepest into the subsurface during peak river discharge, while under base flow conditions, anoxic groundwater dominated shallower depths. Over a 70 cm thick interval, riverbed sediments were therefore exposed to seasonally fluctuating redox conditions and hosted microbial populations statistically different from those at both shallower and deeper locations. Additionally, microbial populations within this zone were shown to be the most dynamic across sampling time points, underlining the critical role that hyporheic mixing plays in constraining microbial abundances. Given such mixing effects, we anticipate that future changes in river discharge in mountainous, semiarid western U.S. watersheds may affect microbial community structure and function in riverbed environments, with potential implications for biogeochemical processes in riparian regions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Helmreich, Grant W.; Hunn, John D.; Skitt, Darren J.
2017-02-01
Coated particle fuel batch J52O-16-93164 was produced by Babcock and Wilcox Technologies (BWXT) for possible selection as fuel for the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation test in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR), or may be used as demonstration production-scale coated particle fuel for other experiments. The tristructural-isotropic (TRISO) coatings were deposited in a 150-mm-diameter production-scale fluidizedbed chemical vapor deposition (CVD) furnace onto 425-μm-nominal-diameter spherical kernels from BWXT lot J52L-16-69316. Each kernel contained a mixture of 15.5%-enriched uranium carbide and uranium oxide (UCO) and was coated with four consecutive CVD layers:more » a ~50% dense carbon buffer layer with 100-μm-nominal thickness, a dense inner pyrolytic carbon (IPyC) layer with 40-μm-nominal thickness, a silicon carbide (SiC) layer with 35-μm-nominal thickness, and a dense outer pyrolytic carbon (OPyC) layer with 40-μm-nominal thickness. The TRISO-coated particle batch was sieved to upgrade the particles by removing over-sized and under-sized material, and the upgraded batch was designated by appending the letter A to the end of the batch number (i.e., 93164A).« less
NASA Astrophysics Data System (ADS)
Ahmed, Naveed; Alahmari, Abdulrahman M.; Darwish, Saied; Naveed, Madiha
2016-12-01
Micro-channels are considered as the integral part of several engineering devices such as micro-channel heat exchangers, micro-coolers, micro-pulsating heat pipes and micro-channels used in gas turbine blades for aerospace applications. In such applications, a fluid flow is required to pass through certain micro-passages such as micro-grooves and micro-channels. The fluid flow characteristics (flow rate, turbulence, pressure drop and fluid dynamics) are mainly established based on the size and accuracy of micro-passages. Variations (oversizing and undersizing) in micro-passage's geometry directly affect the fluid flow characteristics. In this study, the micro-channels of several sizes are fabricated in well-known aerospace nickel alloy (Inconel 718) through laser beam micro-milling. The variations in geometrical characteristics of different-sized micro-channels are studied under the influences of different parameters of Nd:YAG laser. In order to have a minimum variation in the machined geometries of each size of micro-channel, the multi-objective optimization of laser parameters has been carried out utilizing the response surface methodology approach. The objective was set to achieve the targeted top widths and depths of micro-channels with minimum degree of taperness associated with the micro-channel's sidewalls. The optimized sets of laser parameters proposed for each size of micro-channel can be used to fabricate the micro-channels in Inconel 718 with minimum amount of geometrical variations.
Optical modelling of far-infrared astronomical instrumentation exploiting multimode horn antennas
NASA Astrophysics Data System (ADS)
O'Sullivan, Créidhe; Murphy, J. Anthony; Mc Auley, Ian; Wilson, Daniel; Gradziel, Marcin L.; Trappe, Neil; Cahill, Fiachra; Peacocke, T.; Savini, G.; Ganga, K.
2014-07-01
In this paper we describe the optical modelling of astronomical telescopes that exploit bolometric detectors fed by multimoded horn antennas. In cases where the horn shape is profiled rather than being a simple cone, we determine the beam at the horn aperture using an electromagnetic mode-matching technique. Bolometers, usually placed in an integrating cavity, can excite many hybrid modes in a corrugated horn; we usually assume they excite all modes equally. If the waveguide section feeding the horn is oversized these modes can propagate independently, thereby increasing the throughput of the system. We use an SVD analysis on the matrix that describes the scattering between waveguide (TE/TM) modes to recover the independent orthogonal fields (hybrid modes) and then propagate these to the sky independently where they are added in quadrature. Beam patterns at many frequencies across the band are then added with a weighting appropriate to the source spectrum. Here we describe simulations carried out on the highest-frequency (857-GHz) channel of the Planck HFI instrument. We concentrate in particular on the use of multimode feedhorns and consider the effects of possible manufacturing tolerances on the beam on the sky. We also investigate the feasibility of modelling far-out sidelobes across a wide band for electrically large structures and bolometers fed by multi-mode feedhorns. Our optical simulations are carried out using the industry-standard GRASP software package.
O'Keeffe, C; Champion, S; Allsop, D
2015-12-01
Forensic awareness and the declining availability of firearms have resulted in an increase in the use of modified and re-activated firearms in crime. Although some modifications are undertaken to simply acquire a functioning firearm, others are perpetrated as a direct forensic countermeasure to prevent the association between a firearm and a crime. This article describes the effects of these modifications on bullet striation patterns imparted from the barrel to a fired bullet. The key results indicated that the investigated modifications display assessable characteristics. The use of an oversized barrel imparted striations consistent with firing with the absence of typical rifling. Subsequent or consecutively fired bullets possessed striation variations, with the first showing the least evidence of striations. The application of a choke resulted in more obvious bullet elongation compared to a smoothbore barrel. The restriction caused merging of lands and groves of the imparted rifling and obscured their usual definition. Effects of breech adaption were also characterised by observing the buckling and enlargement of the cartridge case. This deformity of the cartridge case was most evident when the barrel pressure increased due to the presence of the choke. From this study it was evident that unique characteristic impressions associated with different modifications most commonly found in criminal investigations can be utilised by a forensic expert and impart significant intelligence to an investigation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Simplified THz Instrumentation for High-Field DNP-NMR Spectroscopy
Sirigiri, Jagadishwar R.
2012-01-01
We present an alternate simplified concept to irradiate a nuclear magnetic resonance sample with terahertz (THz) radiation for dynamic nuclear polarization (DNP) experiments using the TE01 circular waveguide mode for transmission of the THz power and the illumination of the DNP sample by either the TE01 or TE11 mode. Using finite element method and 3D electromagnetic simulations we demonstrate that the average value of the transverse magnetic field induced by the THz radiation and responsible for the DNP effect using the TE11 or the TE01 mode are comparable to that generated by the HE11 mode and a corrugated waveguide. The choice of the TE11/TE01 mode allows the use of a smooth-walled, oversized waveguide that is easier to fabricate and less expensive than a corrugated waveguide required for transmission of the HE11 mode. Also, the choice of the TE01 mode can lead to a simplification of gyrotron oscillators that operate in the TE0n mode, by employing an on-axis rippled-wall mode converter to convert the TE0n mode into the TE01 mode either inside or outside of the gyrotron tube. These novel concepts will lead to a significant simplification of the gyrotron, the transmission line and the THz coupler, which are the three main components of a DNP system. PMID:22977293
Estimation of Fine and Oversize Particle Ratio in a Heterogeneous Compound with Acoustic Emissions.
Nsugbe, Ejay; Ruiz-Carcel, Cristobal; Starr, Andrew; Jennions, Ian
2018-03-13
The final phase of powder production typically involves a mixing process where all of the particles are combined and agglomerated with a binder to form a single compound. The traditional means of inspecting the physical properties of the final product involves an inspection of the particle sizes using an offline sieving and weighing process. The main downside of this technique, in addition to being an offline-only measurement procedure, is its inability to characterise large agglomerates of powders due to sieve blockage. This work assesses the feasibility of a real-time monitoring approach using a benchtop test rig and a prototype acoustic-based measurement approach to provide information that can be correlated to product quality and provide the opportunity for future process optimisation. Acoustic emission (AE) was chosen as the sensing method due to its low cost, simple setup process, and ease of implementation. The performance of the proposed method was assessed in a series of experiments where the offline quality check results were compared to the AE-based real-time estimations using data acquired from a benchtop powder free flow rig. A designed time domain based signal processing method was used to extract particle size information from the acquired AE signal and the results show that this technique is capable of estimating the required ratio in the washing powder compound with an average absolute error of 6%.
Hierarchically nested river landform sequences
NASA Astrophysics Data System (ADS)
Pasternack, G. B.; Weber, M. D.; Brown, R. A.; Baig, D.
2017-12-01
River corridors exhibit landforms nested within landforms repeatedly down spatial scales. In this study we developed, tested, and implemented a new way to create river classifications by mapping domains of fluvial processes with respect to the hierarchical organization of topographic complexity that drives fluvial dynamism. We tested this approach on flow convergence routing, a morphodynamic mechanism with different states depending on the structure of nondimensional topographic variability. Five nondimensional landform types with unique functionality (nozzle, wide bar, normal channel, constricted pool, and oversized) represent this process at any flow. When this typology is nested at base flow, bankfull, and floodprone scales it creates a system with up to 125 functional types. This shows how a single mechanism produces complex dynamism via nesting. Given the classification, we answered nine specific scientific questions to investigate the abundance, sequencing, and hierarchical nesting of these new landform types using a 35-km gravel/cobble river segment of the Yuba River in California. The nested structure of flow convergence routing landforms found in this study revealed that bankfull landforms are nested within specific floodprone valley landform types, and these types control bankfull morphodynamics during moderate to large floods. As a result, this study calls into question the prevailing theory that the bankfull channel of a gravel/cobble river is controlled by in-channel, bankfull, and/or small flood flows. Such flows are too small to initiate widespread sediment transport in a gravel/cobble river with topographic complexity.
Sharifi, Reza; Hoedemaker, Martina
2009-01-01
The objective of this retrospective field study was to associate the type and smell of discharge, the size of the uterus, the ovarian and treatment status, and the time to diagnosis of animals with chronic clinical endometritis (CCE) with the incidence of ovarian cysts and with a marked loss in body condition in German Holstein Friesian cows. Two hundred and sixty-four cows diagnosed with CCE from day 14 to day 42 postpartum participated in this study. In addition, 100 days milk production and the parity of the animals were included in the analysis. With the use of logistic regression, a purulent vaginal discharge (≥ 50% pus), the decision not to treat the animals for CCE and a high 100 days milk production proved to be significant factors for the incidence of ovarian cysts. Additionally, the type of discharge showed interactions with the parity and the smell of the discharge, as more animals with fetid and purulent discharge and more animals in the first lactation with a purulent discharge developed ovarian cysts. A high milk production and the parity showed associations with an excessive body condition score loss. Additionally, more animals with a diagnosis of an oversized uterus in comparison to cows with an early involution experienced a considerable reduction in their nutritional condition. PMID:19934600
Reclaimed mineland curve number response to temporal distribution of rainfall
Warner, R.C.; Agouridis, C.T.; Vingralek, P.T.; Fogle, A.W.
2010-01-01
The curve number (CN) method is a common technique to estimate runoff volume, and it is widely used in coal mining operations such as those in the Appalachian region of Kentucky. However, very little CN data are available for watersheds disturbed by surface mining and then reclaimed using traditional techniques. Furthermore, as the CN method does not readily account for variations in infiltration rates due to varying rainfall distributions, the selection of a single CN value to encompass all temporal rainfall distributions could lead engineers to substantially under- or over-size water detention structures used in mining operations or other land uses such as development. Using rainfall and runoff data from a surface coal mine located in the Cumberland Plateau of eastern Kentucky, CNs were computed for conventionally reclaimed lands. The effects of temporal rainfall distributions on CNs was also examined by classifying storms as intense, steady, multi-interval intense, or multi-interval steady. Results indicate that CNs for such reclaimed lands ranged from 62 to 94 with a mean value of 85. Temporal rainfall distributions were also shown to significantly affect CN values with intense storms having significantly higher CNs than multi-interval storms. These results indicate that a period of recovery is present between rainfall bursts of a multi-interval storm that allows depressional storage and infiltration rates to rebound. ?? 2010 American Water Resources Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Danczak, Robert E.; Sawyer, Audrey H.; Williams, Kenneth H.
Riverbed microbial communities play an oversized role in many watershed ecosystem functions, including the processing of organic carbon, cycling of nitrogen, and alterations to metal mobility. The structure and activity of microbial assemblages depend in part on geochemical conditions set by river-groundwater exchange or hyporheic exchange. In order to assess how seasonal changes in river-groundwater mixing affect these populations in a snowmelt-dominated fluvial system, vertical sediment and pore water profiles were sampled at three time points at one location in the hyporheic zone of the Colorado River and analyzed by using geochemical measurements, 16S rRNA gene sequencing, and ecological modeling.more » Oxic river water penetrated deepest into the subsurface during peak river discharge, while under base flow conditions, anoxic groundwater dominated shallower depths. Over a 70 cm thick interval, riverbed sediments were therefore exposed to seasonally fluctuating redox conditions and hosted microbial populations statistically different from those at both shallower and deeper locations. Additionally, microbial populations within this zone were shown to be the most dynamic across sampling time points, underlining the critical role that hyporheic mixing plays in constraining microbial abundances. Given such mixing effects, we anticipate that future changes in river discharge in mountainous, semiarid western U.S. watersheds may affect microbial community structure and function in riverbed environments, with potential implications for biogeochemical processes in riparian regions.« less
Computational Study of Axial Fatigue for Peripheral Nitinol Stents
NASA Astrophysics Data System (ADS)
Meoli, Alessio; Dordoni, Elena; Petrini, Lorenza; Migliavacca, Francesco; Dubini, Gabriele; Pennati, Giancarlo
2014-07-01
Despite their success as primary treatment for vascular diseases, Nitinol peripheral stents are still affected by complications related to fatigue failure. Hip and knee movements during daily activities produce large and cyclic deformations of the superficial femoral artery, that concomitant to the effects of pulsatile blood pressure, may cause fatigue failure in the stent. Fatigue failure typically occurs in cases of very extended lesions, which often require the use of two or more overlapping stents. In this study, finite element models were used to study the fatigue behavior of Nitinol stents when subjected to cyclic axial compression in different conditions. A specific commercial Nitinol stent was chosen for the analysis and subjected to cyclic axial compression typical of the femoral vascular region. Three different configurations were investigated: stent alone, stent deployed in a tube, and two overlapping stents deployed in a tube. Results confirm that stent oversizing has an influence in determining both the mean and amplitude strains induced in the stent and plays an important role in determining the fatigue response of Nitinol stents. In case of overlapping stents, numerical results suggest higher amplitude strains concentrate in the region close to the overlapping portion where the abrupt change in stiffness causes higher cyclic compression. These findings help to explain the high incidence of stent fractures observed in various clinical trials located close to the overlapping portion.
Ito, Asahiro; Iwata, Shinichi; Mizutani, Kazuki; Nonin, Shinichi; Nishimura, Shinsuke; Takahashi, Yosuke; Yamada, Tokuhiro; Murakami, Takashi; Shibata, Toshihiko; Yoshiyama, Minoru
2018-03-01
Alteration in mitral valve morphology resulting from retrograde stiff wire entanglement sometimes causes hemodynamically significant acute mitral regurgitation (MR) during transfemoral transcatheter aortic valve replacement (TAVR). Little is known about the echocardiographic parameters related to hemodynamically significant acute MR. This study population consisted of 64 consecutive patients who underwent transfemoral TAVR. We defined hemodynamically significant acute MR as changes in the severity of MR with persistent hypotension (systolic blood pressure < 80-90 mm Hg or mean arterial pressure 30 mm Hg lower than baseline). Hemodynamically significant acute MR occurred in 5 cases (7.8%). Smaller left ventricular end-systolic diameter (LVDs), larger ratios of the coiled section of stiff wire tip to LVDs (wire-width/LVDs), and higher Wilkins score were significantly associated with hemodynamically significant acute MR (P < .05), whereas the parameters of functional MR (annular area, anterior-posterior diameter, tenting area, and coaptation length) were not. Moreover, when patients were divided into 4 groups according to wire-width/LVDs and Wilkins score, the group with the larger wire-width/LVDs and higher Wilkins score improved prediction rates (P < .05). Small left ventricle or wire oversizing and calcific mitral apparatus were predictive of hemodynamically significant acute MR. These findings are important for risk stratification, and careful monitoring using intraoperative transesophageal echocardiography may improve the safety in this population. © 2017, Wiley Periodicals, Inc.
Neben, Cynthia L.; Harfe, Brian D.; Linde, Anders
2017-01-01
The interaction between signaling pathways is a central question in the study of organogenesis. Using the developing murine tongue as a model, we uncovered unknown relationships between Sonic hedgehog (SHH) and retinoic acid (RA) signaling. Genetic loss of SHH signaling leads to enhanced RA activity subsequent to loss of SHH-dependent expression of Cyp26a1 and Cyp26c1. This causes a cell identity switch, prompting the epithelium of the tongue to form heterotopic minor salivary glands and to overproduce oversized taste buds. At developmental stages during which Wnt10b expression normally ceases and Shh becomes confined to taste bud cells, loss of SHH inputs causes the lingual epithelium to undergo an ectopic and anachronic expression of Shh and Wnt10b in the basal layer, specifying de novo taste placode induction. Surprisingly, in the absence of SHH signaling, lingual epithelial cells adopted a Merkel cell fate, but this was not caused by enhanced RA signaling. We show that RA promotes, whereas SHH, acting strictly within the lingual epithelium, inhibits taste placode and lingual gland formation by thwarting RA activity. These findings reveal key functions for SHH and RA in cell fate specification in the lingual epithelium and aid in deciphering the molecular mechanisms that assign cell identity. PMID:28715412
Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy
NASA Technical Reports Server (NTRS)
Newman, Kevin Edward; Belikov, Ruslan; Guyon, Olivier; Balasubramanian, Kunjithapatham; Wilson, Dan
2013-01-01
Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.
NASA Astrophysics Data System (ADS)
Danczak, Robert E.; Sawyer, Audrey H.; Williams, Kenneth H.; Stegen, James C.; Hobson, Chad; Wilkins, Michael J.
2016-12-01
Riverbed microbial communities play an oversized role in many watershed ecosystem functions, including the processing of organic carbon, cycling of nitrogen, and alterations to metal mobility. The structure and activity of microbial assemblages depend in part on geochemical conditions set by river-groundwater exchange or hyporheic exchange. To assess how seasonal changes in river-groundwater mixing affect these populations in a snowmelt-dominated fluvial system, vertical sediment and pore water profiles were sampled at three time points at one location in the hyporheic zone of the Colorado River and analyzed by using geochemical measurements, 16S rRNA gene sequencing, and ecological modeling. Oxic river water penetrated deepest into the subsurface during peak river discharge, while under base flow conditions, anoxic groundwater dominated shallower depths. Over a 70 cm thick interval, riverbed sediments were therefore exposed to seasonally fluctuating redox conditions and hosted microbial populations statistically different from those at both shallower and deeper locations. Additionally, microbial populations within this zone were shown to be the most dynamic across sampling time points, underlining the critical role that hyporheic mixing plays in constraining microbial abundances. Given such mixing effects, we anticipate that future changes in river discharge in mountainous, semiarid western U.S. watersheds may affect microbial community structure and function in riverbed environments, with potential implications for biogeochemical processes in riparian regions.
Sachs, Michael
2002-01-01
Although we can not find new disclosures or new ways of describing anatomical structures in the "Anatomischen Tabellen", a text-book written by Johann Adam Kulmus (1689-1745), it has had it's influence in the development of medicine, not only in Germany but in Japan. The "Anatomischen Tabellen" has been one of the most published anatomical text-books of the 18th century. This book was concepted by the medical doctor Kulmus, who was born in the German town Breslau and who was living in Danzig, especially to educate the apprentices and fellows of surgeons in German language. Therefore the book was equiped with several copper-plates for illustration. During the years from 1722 to 1814 23 different editions were found, from those were 14 in German, 5 in Latin and one each in French and Netherland. Not one other anatomical textbooks of the 18th century has had such an abundance of editions. The disadvantage of the former used oversized anatomical atlases was their being published in latin and therefore they have been without any use and much too expensive for educational purposes for young surgeons. The "Anatomischen Tabellen" has been the first occidental text-book of anatomy to be translated into japanese to be published in 1774, supplied with numerous wooden engravings.
Aero Spacelines B377SG Super Guppy on Ramp Loading the X-24B and HL-10 Lifting Bodies.
NASA Technical Reports Server (NTRS)
1976-01-01
The Aero Spacelines B377SG Super Guppy was at Dryden in May, 1976, to ferry the X-24 and HL-10 lifting bodies from the Center to the Air Force Museum at Wright-Patterson Air Force Base, Ohio. The oversized cargo aircraft is a further modification of the B377PG Pregnant Guppy, which was built to transport outsized cargo for NASA's Apollo program, primarily to carry portions of the Saturn V rockets from the manufacturer to Cape Canaveral. The original Guppy modification incorporated the wings, engines, lower fuselage and tail from a Boeing 377 Stratocruiser with a huge upper fuselage more than 20 feet in diameter. The Super Guppy further expanded the fuselage added a taller vertical tail for better lateral stability. A later version, the Super Guppy Turbine, is still in occasional use by NASA to transport oversize structures. The X-24 was one of a group of lifting bodies flown by the NASA Flight Research Center (now Dryden Flight Research Center), Edwards, California, in a joint program with the U.S. Air Force at Edwards Air Force Base from 1963 to 1975. The lifting bodies were used to demonstrate the ability of pilots to maneuver and safely land wingless vehicles designed to fly back to Earth from space and be landed like an airplane at a predetermined site. Lifting bodies' aerodynamic lift, essential to flight in the atmosphere, was obtained from their shape. The addition of fins and control surfaces allowed the pilots to stabilize and control the vehicles and regulate their flight paths. Built by Martin Aircraft Company, Maryland, for the U.S. Air Force, the X-24A was a bulbous vehicle shaped like a teardrop with three vertical fins at the rear for directional control. It weighed 6,270 pounds, was 24.5 feet long and 11.5 feet wide (measuring just the fuselage, not the distance between the tips of the outboard fins). Its first unpowered glide flight was on April 17, 1969, with Air Force Maj. Jerauld Gentry at the controls. Gentry also piloted its first powered flight on March 19, 1970. The X-24A was flown 28 times in the program that, like the HL-10, validated the concept that a Space Shuttle vehicle could be landed unpowered. The fastest speed achieved by the X-24A was 1,036 miles per hour (mph--Mach 1.6). Its maximum altitude was 71,400 feet. It was powered by an XLR-11 rocket engine with a maximum theoretical vacuum thrust of 8,480 pounds. The X-24A was later modified into the X-24B. The bulbous shape of the X-24A was converted into a 'flying flatiron' shape with a rounded top, flat bottom, and double delta platform that ended in a pointed nose. The X-24B demonstrated that accurate unpowered reentry vehicle landings were operationally feasible. Top speed achieved by the X-24B was 1,164 mph and the highest altitude it reached was 74,130 feet. The vehicle is on display at the Air Force Museum, Wright-Patterson Air Force Base, Ohio. The pilot on the last powered flight of the X-24B was Bill Dana, who also flew the last X-15 flight about seven years earlier. The X-24A shape was later borrowed for the X-38 Crew Return Vehicle (CRV) technology demonstrator for the International Space Station. The X-24B is on public display at the Air Force Museum, Wright-Patterson AFB, Ohio. The HL-10 was delivered to the FRC by Northrop in January 1966. Its first flight was on Dec. 22 of the same year. The pilot was Bruce Peterson. The HL-10 was flown 37 times and it set several program records. On Feb. 18, 1970, Air Force test pilot Maj. Peter Hoag flew it to 1,228 mph (Mach 1.86), fastest speed of any of the lifting bodies. Nine days later, NASA's Bill Dana flew the HL-10 to 90,303 feet, the highest altitude reached by any of the lifting body vehicles. The HL-10 was also the first lifting body to fly supersonically--on May 9, 1969, with Manke at the controls. The HL-10 featured a flat bottom and rounded top -- much like an airfoil -- and it had a delta planform. In its final configuration, three vertical fins, two of them canted outwards from the body and a tall center fin, gave the craft directional control. A flush canopy blended into the smooth rounded nose. It was about 21 feet long, with a span of 13.6 feet. Its glide-flight weight was 6,473 lbs. and its maximum gross weight was over 10,000 lbs. Flights with the HL-10 contributed substantially to the decision to design the space shuttles without air-breathing engines that would have been used for landings. Its final flight was on July 17, 1970. The HL-10 is now on public display at Dryden.
Kühle, H J; Hoch, C; Rautzenberg, P; Jansen, F
2001-10-01
Can video assisted observation of visual attention, facial expression and motor skills contribute to the diagnosis of attention deficit/hyperactivity disorder (ADHD)? 20 children from 6 to 10 years of age, diagnosed for ADHD following the DSM-IV criteria, and an age and sex matched control group of 20 children with harmless upper airway infections were filmed during 3 minutes playing cards with their mothers and 7 minutes of oral arithmetic exercises. Two persons were trained for eight hours in recognizing 22 signs for visual attention loss, alterated facial expression like oversized and sustained smile and abnormal motor skills in ADHD-patient videos. Then they viewed minutes 2 and 3 and 3 and 4 of the 40 children in a randomized sequence and scored the signs. 8 of the 22 signs showed high (r > .75) and 9 showed medium (r > .6) interrater correlations. The presence of signs in the ADHD and in the control group was highly significantly different (a = 0.01, U-Test of Mann and Whitney) for 10 of the 22 signs and significantly different for other 4 signs (a = 0.05). The four field table comparison between the frequency of the signs showed correct positioning in 80% of all cases. The loss of visual attention was the most frequent sign in ADHD children. The signs of alterated facial expression were also among the highly correlated signs. These are used by us to find the individual dose for stimulant medication.
Goel, Sonu; Kumar, Ravinder; Lal, Pranay; Tripathi, Jp; Singh, Rana J; Rathinam, Arul; Christian, Anant
2014-01-01
Section 5 of India's tobacco control legislation "Cigarettes and Other Tobacco Products Act (COTPA), 2003"comprehensively prohibits all kinds of tobacco advertisement, promotion and sponsorship (TAPS), but permits advertisments at the point-of-sale (POS) under certain conditions. This provision has been exploited by the tobacco companies to promote their products. To measure compliance with the provisions of Section 5 of Indian tobacco control legislation (COTPA, 2003) at point of sale. A cross-sectional survey using an observation checklist was conducted in 1860 POS across three jurisdictions (Chennai city, District Vadodara and District Mohali) in India. The most common mode of advertisement of tobacco products was product showcasing (51.1%), followed by dangles (49.6%), stickers (33.8%) and boards (27.1%). More than one fourth of POS were found violating legal provisions for displaying advertisement boards in one or other forms (oversized, extended to full body lenth of POS, displayed brandname/ packshot and promotional messages). Advertisement boards (16.3%) without health warnings were also found and wherever found, more than 90% health warning were not as per the specification in respect to size, font and background color. Point of sale advertising is aggressively used by the tobacco industry to promote their products. There is an urgent need of effective implementation of a comprehensive ban on tobacco product advertisement, promotion and sponsorship at point of sale.
Amplatzer vascular plug for arteriovenous hemodialysis access occlusion: initial experience.
Bui, J T; Gaba, R C; Knuttinen, M G; West, D L; Owens, C A
2009-01-01
The Amplatzer Vascular Plug (AVP; AGA Medical, Golden Valley, MN) is a recently developed self-expanding metallic device indicated for peripheral vascular embolizations. Herein, we describe use of this device in the treatment of vascular complications related to arteriovenous hemodialysis fistulas and grafts. This HIPAA compliant retrospective study was approved by the institutional review board with informed consent waived. Six patients with problematic arteriovenous access underwent access occlusion using the AVP. Procedure indications included vascular steal syndrome in five patients, and enlarging vascular aneurysms in one patient. Contraindications for surgical correction were determined by the referring surgeon. AVP embolizations were performed using devices oversized by 50% introduced through vascular sheaths positioned within vein segments just beyond the arteriovenous anastomoses. Noninvasive evaluation of the involved extremity was performed pre- and post-embolization in addition to clinical follow-up examinations. Measured outcomes included success of angiographic occlusion, improvement in distal arterial flow, AVP number, AVP diameter, time to access occlusion, and clinical symptomatic improvement. Technical success was 100%, with complete arteriovenous access occlusion accomplished in all cases, with an average of 1.5 AVPs used per patient. Mean time to access occlusion was 19.3 minutes. Angiographic improvement in distal arterial flow was immediately evident and resolution of clinical symptoms occurred in all patients, with mean long-term follow-up of 16 months. No procedure-related complications were encountered. The Amplatzer Vascular Plug provides a minimally invasive and efficacious method for embolization of problematic arteriovenous hemodialysis access.
Complementing hydropower with PV and wind: optimal energy mix in a fully renewable Switzerland
NASA Astrophysics Data System (ADS)
Dujardin, Jérôme; Kahl, Annelen; Kruyt, Bert; Lehning, Michael
2017-04-01
Like several other countries, Switzerland plans to phase out its nuclear power production and will replace most or all of it by renewables. Switzerland has the chance to benefit from a large hydropower potential and has already exploited almost all of it. Currently about 60% of the Swiss electricity consumption is covered by hydropower, which will eventually leave a gap of about 40% to the other renewables mainly composed of photovoltaics (PV) and wind. With its high flexibility, storage hydropower will play a major role in the future energy mix, providing valuable power and energy balance. Our work focuses on the interplay between PV, wind and storage hydropower, to analyze the dynamics of this complex system and to identify the best PV-wind mixing ratio. Given the current electricity consumption and the currently installed pumping capacity of the storage hydropower plants, it appears that the Swiss hydropower system can completely alleviate the intermittency of PV and wind. However, some seasonal mismatch between production and demand will remain, but we show that oversizing the production from PV and wind or enlarging the reservoir capacity can be a solution to keep it to an acceptable level or even eliminate it. We found that PV, wind and hydropower performs the best together when the share of PV in the solar - wind mix is between 20 and 60%. These findings are quantitatively specific for Switzerland but qualitatively transferable to similar mountainous environments with abundant hydropower resources.
Neutron imaging of diabatic two-phase flows relevant to air conditioning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geoghegan, Patrick J; Sharma, Vishaldeep
The design of the evaporator of an air conditioning system relies heavily on heat transfer coefficients and pressure drop correlations that predominantly involve an estimate of the changing void fraction and the underlying two-phase flow regime. These correlations dictate whether the resulting heat exchanger is oversized or not and the amount of refrigerant charge necessary to operate. The latter is particularly important when dealing with flammable or high GWP refrigerants. Traditional techniques to measure the void fraction and visualize the flow are either invasive to the flow or occur downstream of the evaporator, where some of the flow distribution willmore » have changed. Neutron imaging has the potential to visualize two-phase flow in-situ where an aluminium heat exchanger structure becomes essentially transparent to the penetrating neutrons. The subatomic particles are attenuated by the passing refrigerant flow. The resulting image may be directly related to the void fraction and the overall picture provides a clear insight into the flow regime present. This work presents neutron images of the refrigerant Isopentane as it passes through the flow channels of an aluminium evaporator at flowrates relevant to air conditioning. The flow in a 4mm square macro channel is compared to that in a 250 m by 750 m rectangular microchannel in terms of void fraction and regime. All neutron imaging experiments were conducted at the High Flux Isotope Reactor, an Oak Ridge National Laboratory facility« less
Reinert, Christiane; Kremmler, Lukas; Burock, Susen; Bogdahn, Ulrich; Wick, Wolfgang; Gleiter, Christoph H; Koller, Michael; Hau, Peter
2014-01-01
In randomised controlled trials (RCTs), patient informed consent documents are an essential cornerstone of the study flow. However, these documents are often oversized in format and content. Clinical experience suggests that study information sheets are often not used as an aid to decision-making due to their complexity. We analysed nine patient informed consent documents from clinical neuro-oncological phase III-studies running at a German Brain Tumour Centre with the objective to investigate the quality of these documents. Text length, formal layout, readability, application of ethical and legal requirements, scientific evidence and social aspects were used as rating categories. Results were assessed quantitatively by two independents investigators and were depicted using net diagrams. All patient informed consent documents were of insufficient quality in all categories except that ethical and legal requirements were fulfilled. Notably, graduate levels were required to read and understand five of nine consent documents. Quality deficits were consistent between the individual study information texts. Irrespective of formal aspects, a document that is intended to inform and motivate patients to participate in a study needs to be well-structured and understandable. We therefore strongly mandate to re-design patient informed consent documents in a patient-friendly way. Specifically, standardised components with a scientific foundation should be provided that could be retrieved at various times, adapted to the mode of treatment and the patient's knowledge, and could weigh information dependent of the stage of treatment decision. Copyright © 2013 Elsevier Ltd. All rights reserved.
Central Facilities Area Sewage Lagoon Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cole, Mark R.
2013-12-01
The Central Facilities Area (CFA), located in Butte County, Idaho, at the Idaho National Laboratory has an existing wastewater system to collect and treat sanitary wastewater and non-contact cooling water from the facility. The existing treatment facility consists of three cells: Cell #1 has a surface area of 1.7 acres, Cell #2 has a surface area of 10.3 acres, and Cell #3 has a surface area of 0.5 acres. If flows exceed the evaporative capacity of the cells, wastewater is discharged to a 73.5-acre land application site that uses a center-pivot irrigation sprinkler system. As flows at CFA have decreasedmore » in recent years, the amount of wastewater discharged to the land application site has decreased from 13.64 million gallons in 2004 to no discharge in 2012 and 2013. In addition to the decreasing need for land application, approximately 7.7 MG of supplemental water was added to the system in 2013 to maintain a water level and prevent the clay soil liners in the cells from drying out and “cracking.” The Idaho National Laboratory is concerned that the sewage lagoons and land application site may be oversized for current and future flows. A further concern is the sustainability of the large volumes of supplemental water that are added to the system according to current operational practices. Therefore, this study was initiated to evaluate the system capacity, operational practices, and potential improvement alternatives, as warranted.« less
Hwang, Ho Sik; Cho, Kyong Jin; Rand, Gabriel; Chuck, Roy S; Kwon, Ji Won
2018-06-07
In our study we describe a method that optimizes size of excision and autografting for primary pterygia along with the use of intraoperative MMC and fibrin glue. Our objective is to propose a simple, optimizedpterygium surgical technique with excellent aesthetic outcomes and low rates of recurrence and otheradverse events. Retrospective chart review of 78 consecutive patients with stage III primary pterygia who underwent an optimal excision technique by three experienced surgeons. The technique consisted of removal of the pterygium head, excision of the pterygium body and Tenon's layer limited in proportion to the length of the head, application of intraoperative mitomycin C to the defect, harvest of superior bulbar limbal conjunctival graft, adherence of graft with fibrin glue. Outcomes included operative time, follow up period, pterygium recurrence, occurrences of incorrectly sized grafts, and other complications. All patients were followed up for more than a year. Of the 78 patients, there were 2 cases of pterygium recurrence (2.6%). There was one case of wound dehiscence secondary to small-sized donor conjunctivaand one case of over-sized donor conjunctiva, neither of which required surgical correction. There were no toxic complications associated with the use of mitomycin C. Correlating the excision of the pterygium body and underlying Tenon's layer to the length of the pterygium head, along with the use intraoperative mitomycin C, limbal conjunctival autografting, and fibrin adhesionresulted in excellent outcomes with a low rate of recurrence for primary pterygia.
NASA Technical Reports Server (NTRS)
Dufrene, Warren R., Jr.
2004-01-01
This paper describes the development of a planned approach for Autonomous operation of an Unmanned Aerial Vehicle (UAV). A Hybrid approach will seek to provide Knowledge Generation thru the application of Artificial Intelligence (AI) and Intelligent Agents (IA) for UAV control. The application of many different types of AI techniques for flight will be explored during this research effort. The research concentration will be directed to the application of different AI methods within the UAV arena. By evaluating AI approaches, which will include Expert Systems, Neural Networks, Intelligent Agents, Fuzzy Logic, and Complex Adaptive Systems, a new insight may be gained into the benefits of AI techniques applied to achieving true autonomous operation of these systems thus providing new intellectual merit to this research field. The major area of discussion will be limited to the UAV. The systems of interest include small aircraft, insects, and miniature aircraft. Although flight systems will be explored, the benefits should apply to many Unmanned Vehicles such as: Rovers, Ocean Explorers, Robots, and autonomous operation systems. The flight system will be broken down into control agents that will represent the intelligent agent approach used in AI. After the completion of a successful approach, a framework of applying a Security Overseer will be added in an attempt to address errors, emergencies, failures, damage, or over dynamic environment. The chosen control problem was the landing phase of UAV operation. The initial results from simulation in FlightGear are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Helmreich, Grant W.; Hunn, John D.; Skitt, Darren J.
2017-03-01
Coated particle fuel batches J52O-16-93165, 93166, 93168, 93169, 93170, and 93172 were produced by Babcock and Wilcox Technologies (BWXT) for possible selection as fuel for the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation test in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR). Some of these batches may alternately be used as demonstration coated particle fuel for other experiments. Each batch was coated in a 150-mm-diameter production-scale fluidized-bed chemical vapor deposition (CVD) furnace. Tristructural isotropic (TRISO) coatings were deposited on 425-μm-nominal-diameter spherical kernels from BWXT lot J52R-16-69317 containing a mixture of 15.5%-enriched uranium carbide andmore » uranium oxide (UCO). The TRISO coatings consisted of four consecutive CVD layers: a ~50% dense carbon buffer layer with 100-μm-nominal thickness, a dense inner pyrolytic carbon (IPyC) layer with 40-μm-nominal thickness, a silicon carbide (SiC) layer with 35-μm-nominal thickness, and a dense outer pyrolytic carbon (OPyC) layer with 40-μmnominal thickness. The TRISO-coated particle batches were sieved to upgrade the particles by removing over-sized and under-sized material, and the upgraded batches were designated by appending the letter A to the end of the batch number (e.g., 93165A).« less
Nursing Under the Old Poor Law in Midland and Eastern England 1780-1834.
King, Steven
2015-10-01
This article uses data drawn from the overseers' accounts and supporting documentation in thirty-six parishes spread over four English counties, to answer three basic questions. First, what was the character, extent, structure, range of activities, and remuneration of the nursing labor force under the Old Poor Law between the late eighteenth century and the implementation of the New Poor Law in the 1830s? Second, were there regional and intra-regional differences in the scale and nature of spending on nursing care for the sick poor? Third, how might one explain such differences? The article suggests that nursing became an increasingly important category of spending for the poor law from the later eighteenth century, but that there were significant variations within and (particularly) between English counties in parochial attitudes toward the provision of nursing for the sick poor. These variations can be explained by applying a matrix of explanatory variables ranging from the minor (differences in how parishes defined "nursing") through to the major (long-standing cultural attitudes toward the responsibility of parishioners to their sick compatriots and the ingrained expectations of the sick poor). The article also throws new light on the hidden aspects of female labor force participation, pointing to the development of professional nursing networks long before the later nineteenth century. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Transcatheter aortic-valve implantation with one single minimal contrast media injection.
Arrigo, Mattia; Maisano, Francesco; Haueis, Sabine; Binder, Ronald K; Taramasso, Maurizio; Nietlispach, Fabian
2015-06-01
Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI). Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN. Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics. Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline. Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN. © 2015 Wiley Periodicals, Inc.
Fonteyne, Margot; Gildemyn, Delphine; Peeters, Elisabeth; Mortier, Séverine Thérèse F C; Vercruysse, Jurgen; Gernaey, Krist V; Vervaet, Chris; Remon, Jean Paul; Nopens, Ingmar; De Beer, Thomas
2014-08-01
Classically, the end point detection during fluid bed drying has been performed using indirect parameters, such as the product temperature or the humidity of the outlet drying air. This paper aims at comparing those classic methods to both in-line moisture and solid-state determination by means of Process Analytical Technology (PAT) tools (Raman and NIR spectroscopy) and a mass balance approach. The six-segmented fluid bed drying system being part of a fully continuous from-powder-to-tablet production line (ConsiGma™-25) was used for this study. A theophylline:lactose:PVP (30:67.5:2.5) blend was chosen as model formulation. For the development of the NIR-based moisture determination model, 15 calibration experiments in the fluid bed dryer were performed. Six test experiments were conducted afterwards, and the product was monitored in-line with NIR and Raman spectroscopy during drying. The results (drying endpoint and residual moisture) obtained via the NIR-based moisture determination model, the classical approach by means of indirect parameters and the mass balance model were then compared. Our conclusion is that the PAT-based method is most suited for use in a production set-up. Secondly, the different size fractions of the dried granules obtained during different experiments (fines, yield and oversized granules) were compared separately, revealing differences in both solid state of theophylline and moisture content between the different granule size fractions. Copyright © 2014 Elsevier B.V. All rights reserved.
Neural Biomarkers for Dyslexia, ADHD, and ADD in the Auditory Cortex of Children.
Serrallach, Bettina; Groß, Christine; Bernhofs, Valdis; Engelmann, Dorte; Benner, Jan; Gündert, Nadine; Blatow, Maria; Wengenroth, Martina; Seitz, Angelika; Brunner, Monika; Seither, Stefan; Parncutt, Richard; Schneider, Peter; Seither-Preisler, Annemarie
2016-01-01
Dyslexia, attention deficit hyperactivity disorder (ADHD), and attention deficit disorder (ADD) show distinct clinical profiles that may include auditory and language-related impairments. Currently, an objective brain-based diagnosis of these developmental disorders is still unavailable. We investigated the neuro-auditory systems of dyslexic, ADHD, ADD, and age-matched control children (N = 147) using neuroimaging, magnetencephalography and psychoacoustics. All disorder subgroups exhibited an oversized left planum temporale and an abnormal interhemispheric asynchrony (10-40 ms) of the primary auditory evoked P1-response. Considering right auditory cortex morphology, bilateral P1 source waveform shapes, and auditory performance, the three disorder subgroups could be reliably differentiated with outstanding accuracies of 89-98%. We therefore for the first time provide differential biomarkers for a brain-based diagnosis of dyslexia, ADHD, and ADD. The method allowed not only allowed for clear discrimination between two subtypes of attentional disorders (ADHD and ADD), a topic controversially discussed for decades in the scientific community, but also revealed the potential for objectively identifying comorbid cases. Noteworthy, in children playing a musical instrument, after three and a half years of training the observed interhemispheric asynchronies were reduced by about 2/3, thus suggesting a strong beneficial influence of music experience on brain development. These findings might have far-reaching implications for both research and practice and enable a profound understanding of the brain-related etiology, diagnosis, and musically based therapy of common auditory-related developmental disorders and learning disabilities.
Neural Biomarkers for Dyslexia, ADHD, and ADD in the Auditory Cortex of Children
Serrallach, Bettina; Groß, Christine; Bernhofs, Valdis; Engelmann, Dorte; Benner, Jan; Gündert, Nadine; Blatow, Maria; Wengenroth, Martina; Seitz, Angelika; Brunner, Monika; Seither, Stefan; Parncutt, Richard; Schneider, Peter; Seither-Preisler, Annemarie
2016-01-01
Dyslexia, attention deficit hyperactivity disorder (ADHD), and attention deficit disorder (ADD) show distinct clinical profiles that may include auditory and language-related impairments. Currently, an objective brain-based diagnosis of these developmental disorders is still unavailable. We investigated the neuro-auditory systems of dyslexic, ADHD, ADD, and age-matched control children (N = 147) using neuroimaging, magnetencephalography and psychoacoustics. All disorder subgroups exhibited an oversized left planum temporale and an abnormal interhemispheric asynchrony (10–40 ms) of the primary auditory evoked P1-response. Considering right auditory cortex morphology, bilateral P1 source waveform shapes, and auditory performance, the three disorder subgroups could be reliably differentiated with outstanding accuracies of 89–98%. We therefore for the first time provide differential biomarkers for a brain-based diagnosis of dyslexia, ADHD, and ADD. The method allowed not only allowed for clear discrimination between two subtypes of attentional disorders (ADHD and ADD), a topic controversially discussed for decades in the scientific community, but also revealed the potential for objectively identifying comorbid cases. Noteworthy, in children playing a musical instrument, after three and a half years of training the observed interhemispheric asynchronies were reduced by about 2/3, thus suggesting a strong beneficial influence of music experience on brain development. These findings might have far-reaching implications for both research and practice and enable a profound understanding of the brain-related etiology, diagnosis, and musically based therapy of common auditory-related developmental disorders and learning disabilities. PMID:27471442
NASA Astrophysics Data System (ADS)
Tang, Baojun; Riisgård, Hans Ulrik
2018-03-01
The large water-pumping and particle-capturing gills of the filter-feeding blue mussel Mytilus edulis are oversized for respiratory purposes. Consequently, the oxygen uptake rate of the mussel has been suggested to be rather insensitive to decreasing oxygen concentrations in the ambient water, since the diffusion rate of oxygen from water flowing through the mussel determines oxygen uptake. We tested this hypothesis by measuring the oxygen uptake in mussels exposed to various oxygen concentrations. These concentrations were established via N2-bubbling of the water in a respiration chamber with mussels fed algal cells to stimulate fully opening of the valves. It was found that mussels exposed to oxygen concentrations decreasing from 9 to 2 mg O2/L resulted in a slow but significant reduction in the respiration rate, while the filtration rate remained high and constant. Thus, a decrease of oxygen concentration by 78% only resulted in a 25% decrease in respiration rate. However, at oxygen concentrations below 2 mg O2/L M. edulis responded by gradually closing its valves, resulting in a rapid decrease of filtration rate, concurrent with a rapid reduction of respiration rate. These observations indicated that M. edulis is no longer able to maintain its normal aerobic metabolism at oxygen concentration below 2 mg O2/L, and there seems to be an energy-saving mechanism in bivalve molluscs to strongly reduce their activity when exposed to low oxygen conditions.
Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A
2014-12-23
A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.
Liu, Jing-Han; Zhou, Jun; Ouyang, Xi-Lin; Li, Xi-Jin; Lu, Fa-Qiang
2005-08-01
This study was aimed to further optimize trehalose loading technique including loading temperature, loading time, loading solution and loading concentration of trehalose, based on the established parameters. Loading efficiency in plasma was compared with that in buffer at 37 degrees C; the curves of intracellular trehalose concentration versus loading time at 37 degrees C and 16 degrees C were measured; curves of mean platelet volume (MPV) versus loading time and loading concentration were investigated and compared. According to results obtained, the loaing time, loading temperature, loading solution and trehalose concentration were ascertained for high loading efficiency of trehalose into human platelet. The results showed that the loading efficiency in plasma was markedly higher than that in buffer at 37 degrees C, the loading efficiency in plasma at 37 degrees C was significantly higher than that at 16 degrees C and reached 19.51% after loading for 4 hours, but 6.16% at 16 degrees C. MPV at 16 degrees C was increased by 43.2% than that at 37 degrees C, but had no distinct changes with loading time and loading concentration. In loading at 37 degrees C, MPV increased with loading time and loading concentration positively. Loading time and loading concentration displayed synergetic effect on MPV. MPV increased with loading time and concentration while trehalose loading concentration was above 50 mmol/L. It is concluded that the optimization parameters of trehalose loading technique are 37 degrees C (temperature), 4 hours (leading time), plasma (loading solution), 50 mmol/L (feasible trehalose concentration). The trehalose concentration can be adjusted to meet the requirement of lyophilization.