Sample records for pair-conversion tracker tkr

  1. Gamma Ray Large Area Space Telescope (GLAST) Balloon Flight Engineering Model: Overview

    NASA Technical Reports Server (NTRS)

    Thompson, D. J.; Godfrey, G.; Williams, S. M.; Grove, J. E.; Mizuno, T.; Sadrozinski, H. F.-W.; Kamae, T.; Ampe, J.; Briber, Stuart; Dann, James; hide

    2001-01-01

    The Gamma Ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) is a pair-production high-energy (greater than 20 MeV) gamma-ray telescope being built by an international partnership of astrophysicists and particle physicists for a satellite launch in 2006, designed to study a wide variety of high-energy astrophysical phenomena. As part of the development effort, the collaboration has built a Balloon Flight Engineering Model (BFEM) for flight on a high-altitude scientific balloon. The BFEM is approximately the size of one of the 16 GLAST-LAT towers and contains all the components of the full instrument: plastic scintillator anticoincidence system (ACD), high-Z foil/Si strip pair-conversion tracker (TKR), CsI hodoscopic calorimeter (CAL), triggering and data acquisition electronics (DAQ), commanding system, power distribution, telemetry, real-time data display, and ground data processing system. The principal goal of the balloon flight was to demonstrate the performance of this instrument configuration under conditions similar to those expected in orbit. Results from a balloon flight from Palestine, Texas, on August 4, 2001, show that the BFEM successfully obtained gamma-ray data in this high-background environment.

  2. Supporting the Delivery of Total Knee Replacements Care for Both Patients and Their Clinicians With a Mobile App and Web-Based Tool: Randomized Controlled Trial Protocol.

    PubMed

    Hussain, M Sazzad; Li, Jane; Brindal, Emily; van Kasteren, Yasmin; Varnfield, Marlien; Reeson, Andrew; Berkovsky, Shlomo; Freyne, Jill

    2017-03-01

    Total knee replacement (TKR) surgeries have increased in recent years. Exercise programs and other interventions following surgery can facilitate the recovery process. With limited clinician contact time, patients with TKR have a substantial burden of self-management and limited communication with their care team, thus often fail to implement an effective rehabilitation plan. We have developed a digital orthopedic rehabilitation platform that comprises a mobile phone app, wearable activity tracker, and clinical Web portal in order to engage patients with self-management tasks for surgical preparation and recovery, thus addressing the challenges of adherence to and completion of TKR rehabilitation. The study will determine the efficacy of the TKR platform in delivering information and assistance to patients in their preparation and recovery from TKR surgery and a Web portal for clinician care teams (ie, surgeons and physiotherapists) to remotely support and monitor patient progress. The study will evaluate the TKR platform through a randomized controlled trial conducted at multiple sites (N=5) in a number of states in Australia with 320 patients undergoing TKR surgery; the trial will run for 13 months for each patient. Participants will be randomized to either a control group or an intervention group, both receiving usual care as provided by their hospital. The intervention group will receive the app and wearable activity tracker. Participants will be assessed at 4 different time points: 4 weeks before surgery, immediately before surgery, 12 weeks after surgery, and 52 weeks after surgery. The primary outcome measure is the Oxford Knee Score. Secondary outcome measures include quality of life (Short-Form Health Survey); depression, anxiety, and stress (Depression, Anxiety, and Stress Scales); self-motivation; self-determination; self-efficacy; and the level of satisfaction with the knee surgery and care delivery. The study will also collect quantitative usage data related to all components (app, activity tracker, and Web portal) of the TKR platform and qualitative data on the perceptions of the platform as a tool for patients, carers, and clinicians. Finally, an economic evaluation of the impact of the platform will be conducted. Development of the TKR platform has been completed and deployed for trial. The research protocol is approved by 2 human research ethics committees in Australia. A total of 5 hospitals in Australia (2 in New South Wales, 2 in Queensland, and 1 in South Australia) are expected to participate in the trial. The TKR platform is designed to provide flexibility in care delivery and increased engagement with rehabilitation services. This trial will investigate the clinical and behavioral efficacy of the app and impact of the TKR platform in terms of service satisfaction, acceptance, and economic benefits of the provision of digital services. Australian New Zealand Clinical Trials Registry (ANZCTR) ACTRN12616000504415; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=370536 (Archived by WebCite at http://www.webcitation.org/6oKES0Gp1). ©M Sazzad Hussain, Jane Li, Emily Brindal, Yasmin van Kasteren, Marlien Varnfield, Andrew Reeson, Shlomo Berkovsky, Jill Freyne. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 01.03.2017.

  3. A technical innovation for improving identification of the trackers by the LED cameras in navigation-assisted total knee arthroplasty.

    PubMed

    Darmanis, Spyridon; Toms, Andrew; Durman, Robert; Moore, Donna; Eyres, Keith

    2007-07-01

    To reduce the operating time in computer-assisted navigated total knee replacement (TKR), by improving communication between the infrared camera and the trackers placed on the patient. The innovation involves placing a routinely used laser pointer on top of the camera, so that the infrared cameras focus precisely on the trackers located on the knee to be operated on. A prospective randomized study was performed involving 40 patients divided into two groups, A and B. Both groups underwent navigated TKR, but for group B patients a laser pointer was used to improve the targeting capabilities of the cameras. Without the laser pointer, the camera had to move a mean 9.2 times in order to identify the trackers. With the introduction of the laser pointer, this was reduced to 0.9 times. Accordingly, the additional mean time required without the laser pointer was 11.6 minutes. Time delays are a major problem in computer-assisted surgery, and our technical suggestion can contribute towards reducing the delays associated with this particular application.

  4. Knee Joint Loads and Surrounding Muscle Forces during Stair Ascent in Patients with Total Knee Replacement

    PubMed Central

    Rasnick, Robert; Standifird, Tyler; Reinbolt, Jeffrey A.; Cates, Harold E.

    2016-01-01

    Total knee replacement (TKR) is commonly used to correct end-stage knee osteoarthritis. Unfortunately, difficulty with stair climbing often persists and prolongs the challenges of TKR patents. Complete understanding of loading at the knee is of great interest in order to aid patient populations, implant manufacturers, rehabilitation, and future healthcare research. Musculoskeletal modeling and simulation approximates joint loading and corresponding muscle forces during a movement. The purpose of this study was to determine if knee joint loadings following TKR are recovered to the level of healthy individuals, and determine the differences in muscle forces causing those loadings. Data from five healthy and five TKR patients were selected for musculoskeletal simulation. Variables of interest included knee joint reaction forces (JRF) and the corresponding muscle forces. A paired samples t-test was used to detect differences between groups for each variable of interest (p<0.05). No differences were observed for peak joint compressive forces between groups. Some muscle force compensatory strategies appear to be present in both the loading and push-off phases. Evidence from knee extension moment and muscle forces during the loading response phase indicates the presence of deficits in TKR in quadriceps muscle force production during stair ascent. This result combined with greater flexor muscle forces resulted in similar compressive JRF during loading response between groups. PMID:27258086

  5. Development of a Broad High-Energy Gamma-Ray Telescope using Silicon Strip Detectors

    NASA Technical Reports Server (NTRS)

    Michelson, Peter F.

    1998-01-01

    The research effort has led to the development and demonstration of technology to enable the design and construction of a next-generation high-energy gamma-ray telescope that operates in the pair-production regime (E greater than 10 MeV). In particular, the technology approach developed is based on silicon-strip detector technology. A complete instrument concept based on this technology for the pair-conversion tracker and the use of CsI(T1) crystals for the calorimeter is now the baseline instrument concept for the Gamma-ray Large Area Space Telescope (GLAST) mission. GLAST is NASA's proposed high-energy gamma-ray mission designed to operate in the energy range from 10 MeV to approximately 300 GeV. GLAST, with nearly 100 times the sensitivity of EGRET, operates through pair conversion of gamma-rays and measurement of the direction and energy of the resulting e (+) - e (-) shower. The baseline design, developed with support from NASA includes a charged particle anticoincidence shield, a tracker/converter made of thin sheets of high-Z material interspersed with Si strip detectors, a CsI calorimeter and a programmable data trigger and acquisition system. The telescope is assembled as an array of modules or towers. Each tower contains elements of the tracker, calorimeter, and anticoincidence system. As originally proposed, the telescope design had 49 modules. In the more optimized design that emerged at the end of the grant period the individual modules are larger and the total number in the GLAST array is 25. Also the calorimeter design was advanced substantially to the point that it has a self-contained imaging capability, albeit much cruder than the tracker.

  6. γ-ray telescopes using conversions to e+e- pairs: event generators, angular resolution and polarimetry

    NASA Astrophysics Data System (ADS)

    Gros, P.; Bernard, D.

    2017-02-01

    We benchmark various available event generators in Geant4 and EGS5 in the light of ongoing projects for high angular-resolution pair-conversion telescopes at low energy. We compare the distributions of key kinematic variables extracted from the geometry of the three final state particles. We validate and use as reference an exact generator using the full 5D differential cross-section of the conversion process. We focus in particular on the effect of the unmeasured recoiling nucleus on the angular resolution. We show that for high resolution trackers, the choice of the generator affects the estimated resolution of the telescope. We also show that the current available generator are unable to describe accurately a linearly polarised photon source.

  7. Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain.

    PubMed

    Baker, Katherine M; Foutz, Timothy L; Johnsen, Kyle J; Budsberg, Steven C

    2014-09-01

    To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. 6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by TKR.

  8. Characterizing the recovery trajectories of knee range of motion for one year after total knee replacement.

    PubMed

    Mehta, Saurabh; Rigney, Andrew; Webb, Kyle; Wesney, Jacob; Stratford, Paul W; Shuler, Franklin D; Oliashirazi, Ali

    2018-06-13

    Retrospective analysis of routinely collected clinical data. This study modeled the recovery in knee flexion and extension range of motion (ROM) over 1 year after total knee replacement (TKR). Recovery after TKR has been characterized for self-reported pain and functional status. Literature describing target knee ROM at different follow-up periods after TKR is scarce. Data were extracted for patients who had undergone TKR at a tertiary care hospital at 2, 8, 12, 26, and 52 weeks after TKR. A linear mixed-effects growth model was constructed that investigated the following covariates age, sex, pre-TKR range, body mass index, duration of symptoms, and their interaction with weeks post TKR. Of the 559 patients included (age 64.8 ± 8.5 years), 370 were women and 189 were men. Knee ROM showed the greatest change during the first 12 weeks after TKR, plateauing by 26 weeks. For an average patient, knee flexion increased from approximately 100º 2 weeks post TKR to 117º 52 weeks post TKR. Knee extension increased from approximately 3º knee flexion 2 weeks post TKR to 1º flexion 52 weeks post TKR. The results showed that the maximum gains in knee ROM should be expected within the first 12 weeks with small changes occurring up to 26 weeks after TKR. In addition, age and presurgery knee ROM are associated with the gains in knee ROM and should be factored into the estimation of expected knee ROM at a given follow-up interval after TKR.

  9. Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor.

    PubMed

    Zhao, Dong; Sakoda, Hideyuki; Sawyer, W Gregory; Banks, Scott A; Fregly, Benjamin J

    2008-02-01

    Wear of ultrahigh molecular weight polyethylene remains a primary factor limiting the longevity of total knee replacements (TKRs). However, wear testing on a simulator machine is time consuming and expensive, making it impractical for iterative design purposes. The objectives of this paper were first, to evaluate whether a computational model using a wear factor consistent with the TKR material pair can predict accurate TKR damage measured in a simulator machine, and second, to investigate how choice of surface evolution method (fixed or variable step) and material model (linear or nonlinear) affect the prediction. An iterative computational damage model was constructed for a commercial knee implant in an AMTI simulator machine. The damage model combined a dynamic contact model with a surface evolution model to predict how wear plus creep progressively alter tibial insert geometry over multiple simulations. The computational framework was validated by predicting wear in a cylinder-on-plate system for which an analytical solution was derived. The implant damage model was evaluated for 5 million cycles of simulated gait using damage measurements made on the same implant in an AMTI machine. Using a pin-on-plate wear factor for the same material pair as the implant, the model predicted tibial insert wear volume to within 2% error and damage depths and areas to within 18% and 10% error, respectively. Choice of material model had little influence, while inclusion of surface evolution affected damage depth and area but not wear volume predictions. Surface evolution method was important only during the initial cycles, where variable step was needed to capture rapid geometry changes due to the creep. Overall, our results indicate that accurate TKR damage predictions can be made with a computational model using a constant wear factor obtained from pin-on-plate tests for the same material pair, and furthermore, that surface evolution method matters only during the initial "break in" period of the simulation.

  10. Does circumpatellar electrocautery improve the outcome after total knee replacement?: a prospective, randomised, blinded controlled trial.

    PubMed

    Baliga, S; McNair, C J; Barnett, K J; MacLeod, J; Humphry, R W; Finlayson, D

    2012-09-01

    The incidence of anterior knee pain following total knee replacement (TKR) is reported to be as high as 49%. The source of the pain is poorly understood but the soft tissues around the patella have been implicated. In theory circumferential electrocautery denervates the patella thereby reducing efferent pain signals. However, there is mixed evidence that this practice translates into improved outcomes. We aimed to investigate the clinical effect of intra-operative circumpatellar electrocautery in patients undergoing TKR using the LCS mobile bearing or Kinemax fixed bearing TKR. A total of 200 patients were randomised to receive either circumpatellar electrocautery (diathermy) or not (control). Patients were assessed by visual analogue scale (VAS) for anterior knee pain and Oxford knee score (OKS) pre-operatively and three months, six months and one year post-operatively. Patients and assessors were blinded. There were 91 patients in the diathermy group and 94 in the control. The mean VAS improvement at one year was 3.9 in both groups (control; -10 to 6, diathermy; -9 to 8, p < 0.001 in both cases, paired, two-tailed t-test). There was no significant difference in VAS between the groups at any other time. The mean OKS improvement was 17.7 points (0 to 34) in the intervention group and 16.6 (0 to 42) points in the control (p = 0.36). There was no significant difference between the two groups in OKS at any other time. We found no relevant effect of patellar electrocautery on either VAS anterior knee pain or OKS for patients undergoing LCS and Kinemax TKR.

  11. Associations between socioeconomic status and primary total knee joint replacements performed for osteoarthritis across Australia 2003-10: data from the Australian Orthopaedic Association National Joint Replacement Registry.

    PubMed

    Brennan, Sharon L; Lane, Stephen E; Lorimer, Michelle; Buchbinder, Rachelle; Wluka, Anita E; Page, Richard S; Osborne, Richard H; Pasco, Julie A; Sanders, Kerrie M; Cashman, Kara; Ebeling, Peter R; Graves, Stephen E

    2014-10-28

    Relatively little is known about the social distribution of total knee joint replacement (TKR) uptake in Australia. We examine associations between socioeconomic status (SES) and TKR performed for diagnosed osteoarthritis 2003-10 for all Australian males and females aged ≥ 30 yr. Data of primary TKR (n=213,018, 57.4% female) were ascertained from a comprehensive national joint replacement registry. Residential addresses were matched to Australian Census data to identify area-level social disadvantage, and categorised into deciles. Estimated TKR rates were calculated. Poisson regression was used to model the relative risk (RR) of age-adjusted TKR per 1,000py, stratified by sex and SES. A negative relationship was observed between TKR rates and SES deciles. Females had a greater rate of TKR than males. Surgery utilisation was greatest for all adults aged 70-79 yr. In that age group differences in estimated TKR per 1,000py between deciles were greater for 2010 than 2003 (females: 2010 RR 4.32 and 2003 RR 3.67; males: 2010 RR 2.04 and 2003 RR 1.78). Identifying factors associated with TKR utilisation and SES may enhance resource planning and promote surgery utilisation for end-stage osteoarthritis.

  12. Incidence of total knee replacement subsequent to intra-articular injection of the anti-inflammatory compound LMWF-5A versus saline: a long-term follow-up study to a randomized controlled trial.

    PubMed

    Schwappach, John; Schultz, Joseph; Salottolo, Kristin; Bar-Or, David

    2018-01-01

    The disease modifying potential of osteoarthritis therapies are of increasing interest, including their effects on delaying total knee replacement (TKR). To date, there have been no studies to determine the effect of LMWF-5A, a novel anti-inflammatory compound derived from human serum albumin, on delaying TKR. We evaluated time to TKR three years after patients participated in a randomized trial of three intra-articular injections of LMWF-5A or saline. Patients were contacted via last known phone number and were asked to participate in a short nine item telephone questionnaire; verbal consent was obtained. The primary endpoint was incidence of TKR (%). In total, 39 of 45 patients responded (87% response rate). The overall incidence of TKR was 38.5% (15/39). TKR rates were higher in patients with more severe osteoarthritis defined by Kellgren-Lawrence grade 4, compared to patients with moderate osteoarthritis defined by Kellgren-Lawrence grade 3 (56% vs. 26%, p  = 0.06). Overall, there were no differences in TKR rates by treatment arm (39% LMWF-5A vs. 38% saline, p  = 0.92). In the severe osteoarthritis subset ( n  = 16), treatment with LMWF-5A resulted in a lower incidence of TKR compared to saline vehicle arm (40% vs. 83%, p  = 0.15). TKR rates were significantly lower with LMWF-5A in patients who responded to treatment (14% with LMWF-5A, vs. 100% with saline, p  = 0.03). This study demonstrates significant delays in TKR for patients with severe osteoarthritis treated with LMWF-5A, suggesting that LMWF-5A has the potential to provide structure modifying/preserving therapy in this population.

  13. Utilisation of primary total knee joint replacements across socioeconomic status in the Barwon Statistical Division, Australia, 2006-2007: a cross-sectional study.

    PubMed

    Brennan, Sharon Lee; Stanford, Tyman; Wluka, Anita E; Page, Richard S; Graves, Stephen E; Kotowicz, Mark A; Nicholson, Geoffrey C; Pasco, Julie A

    2012-01-01

    There are few Australian data that examine the association between total knee joint replacement (TKR) utilisation and socioeconomic status (SES). This study examined TKR surgeries with a diagnosis of osteoarthritis (OA) performed for residents of Barwon Statistical Division (BSD) for 2006-2007. Cross-sectional. BSD, South-eastern Victoria, Australia All patients who underwent a TKR for OA, 2006-2007, and whose residential postcode was identified as within the BSD of Australia, and for whom SES data were available, were eligible for inclusion. Primary TKR data ascertained from the Australian Orthopaedic Association National Joint Replacement Registry. Residential addresses were matched with the Australian Bureau of Statistics census data, and the Index of Relative Socioeconomic Disadvantage was used to determine SES, categorised into quintiles whereby quintile 1 indicated the most disadvantaged and quintile 5 the least disadvantaged. Age-specific and sex-specific rates of TKR utilisation per 1000 person-years were reported for 10-year age bands. Females accounted for 62.7% of the 691 primary TKR surgeries performed during 2006-2007. The greatest utilisation rates of TKR in males was 7.6 observed in those aged >79 years, and in 10.2 in females observed in those aged 70-79 years. An increase in TKR was observed for males in SES quintile four compared to quintile 1 in which the lowest utilisation which was observed (p=0.04). No differences were observed in females across SES quintiles. Further investigation is warranted on a larger scale to examine the role that SES may play in TKR utilisation, and to determine whether any social disparities in TKR utilisation reflect health system biases or geographic differences.

  14. Concerns of patients actively contemplating total knee replacement: differences by race and gender.

    PubMed

    Chang, Huan J; Mehta, Priya S; Rosenberg, Aaron; Scrimshaw, Susan C

    2004-02-15

    To examine differences by race/ethnicity and gender in patients' concerns regarding total knee replacement (TKR). Focus groups of patients actively considering TKR were conducted. Discussion included patients' questions and concerns regarding TKR. The software ATLAS.ti was used to tabulate themes by race/ethnicity and gender. Concerns raised by focus group participants were compared with thematic content from patient joint replacement information materials. This comparison used patient literature from 3 high-volume academic TKR centers, the Arthritis Foundation, and the American Academy of Orthopedic Surgeons. All groups shared similar concerns. However, some issues were more prevalent among certain gender and racial groups. For instance, concerns regarding anesthesia were more important to white Americans and concerns regarding recovery were more important to women. Some of these concerns were not addressed in the available patient literature. Different gender and racial subgroups focus on different concerns when considering TKR. These differences may contribute to gender and race/ethnicity disparity seen in TKR use.

  15. Gait analysis of patients with an off-the-shelf total knee replacement versus customized bi-compartmental knee replacement.

    PubMed

    Wang, Henry; Foster, Jonathan; Franksen, Natasha; Estes, Jill; Rolston, Lindsey

    2018-04-01

    Newer TKR designs have been introduced to the market with the aim of overcoming common sizing problems with older TKR designs. Furthermore, since a sizable percentage of patients with OA present with disease limited to the medial/lateral knee compartment in addition to the patellofemoral joint, for whom, a customized bi-compartmental knee replacement (BKR) is available as a treatment option. To date, there is very little information regarding knee strength and mechanics during gait for patients implanted with these modern TKR and BKR designs. The purpose of the study was to evaluate knee strength and mechanics during walking for patients with either a modern off the shelf TKR or a customized BKR and compare these findings to a cohort of healthy controls. Twelve healthy controls, eight BKR, and nine TKR patients participated in the study. Maximal isometric knee strength was evaluated. 3D kinematic and kinetic analyses were conducted for level walking. The TKR knee exhibited less peak extensor torque when compared to, both the BKR and control limbs (p < 0.05). The TKR knee had less extensor moment at stance than both the BKR and control knees (p < 0.05). Both the BKR and control knees displayed larger internal rotation at stance than that of the TKR knee (p < 0.05). This study suggests that, for patients that exhibit isolated OA of the tibiofemoral joint, using a customized BKR implant is a viable treatment option and may contribute to superior mechanical advantages.

  16. Early assessment of the likely cost-effectiveness of a new technology: A Markov model with probabilistic sensitivity analysis of computer-assisted total knee replacement.

    PubMed

    Dong, Hengjin; Buxton, Martin

    2006-01-01

    The objective of this study is to apply a Markov model to compare cost-effectiveness of total knee replacement (TKR) using computer-assisted surgery (CAS) with that of TKR using a conventional manual method in the absence of formal clinical trial evidence. A structured search was carried out to identify evidence relating to the clinical outcome, cost, and effectiveness of TKR. Nine Markov states were identified based on the progress of the disease after TKR. Effectiveness was expressed by quality-adjusted life years (QALYs). The simulation was carried out initially for 120 cycles of a month each, starting with 1,000 TKRs. A discount rate of 3.5 percent was used for both cost and effectiveness in the incremental cost-effectiveness analysis. Then, a probabilistic sensitivity analysis was carried out using a Monte Carlo approach with 10,000 iterations. Computer-assisted TKR was a long-term cost-effective technology, but the QALYs gained were small. After the first 2 years, the incremental cost per QALY of computer-assisted TKR was dominant because of cheaper and more QALYs. The incremental cost-effectiveness ratio (ICER) was sensitive to the "effect of CAS," to the CAS extra cost, and to the utility of the state "Normal health after primary TKR," but it was not sensitive to utilities of other Markov states. Both probabilistic and deterministic analyses produced similar cumulative serious or minor complication rates and complex or simple revision rates. They also produced similar ICERs. Compared with conventional TKR, computer-assisted TKR is a cost-saving technology in the long-term and may offer small additional QALYs. The "effect of CAS" is to reduce revision rates and complications through more accurate and precise alignment, and although the conclusions from the model, even when allowing for a full probabilistic analysis of uncertainty, are clear, the "effect of CAS" on the rate of revisions awaits long-term clinical evidence.

  17. Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation.

    PubMed

    Scholes, Corey; Sahni, Varun; Lustig, Sebastien; Parker, David A; Coolican, Myles R J

    2014-03-01

    The introduction of patient-specific instruments (PSI) for guiding bone cuts could increase the incidence of malalignment in primary total knee arthroplasty. The purpose of this study was to assess the agreement between one type of patient-specific instrumentation (Zimmer PSI) and the pre-operative plan with respect to bone cuts and component alignment during TKR using imageless computer navigation. A consecutive series of 30 femoral and tibial guides were assessed in-theatre by the same surgeon using computer navigation. Following surgical exposure, the PSI cutting guides were placed on the joint surface and alignment assessed using the navigation tracker. The difference between in-theatre data and the pre-operative plan was recorded and analysed. The error between in-theatre measurements and pre-operative plan for the femoral and tibial components exceeded 3° for 3 and 17% of the sample, respectively, while the error for total coronal alignment exceeded 3° for 27% of the sample. The present results indicate that alignment with Zimmer PSI cutting blocks, assessed by imageless navigation, does not match the pre-operative plan in a proportion of cases. To prevent unnecessary increases in the incidence of malalignment in primary TKR, it is recommended that these devices should not be used without objective verification of alignment, either in real-time or with post-operative imaging. Further work is required to identify the source of discrepancies and validate these devices prior to routine use. II.

  18. Comparison of Antagonist Muscle Activity During Walking Between Total Knee Replacement and Control Subjects Using Unnormalized Electromyography.

    PubMed

    Lundberg, Hannah J; Rojas, Idubijes L; Foucher, Kharma C; Wimmer, Markus A

    2016-06-01

    Although satisfactory outcomes have been reported after total knee replacement (TKR), full recovery of muscle strength and physical function is rare. We developed a relative activation index (RAI) to compare leg muscle activity from unnormalized surface electromyography (sEMG) between TKR and control subjects. Nineteen TKR and 19 control subjects underwent gait analysis and sEMG. RAIs were calculated by dividing the average sEMG for 2 consecutive subphases of stance defined by the direction of the external sagittal plane moment (flexion or extension). RAIs and external moments indicate TKR subjects have less initial stance antagonist rectus femoris activity (P = .004), greater middle stance antagonist biceps femoris activity (P < .001), and less late stance agonist biceps femoris activity (P < .001) than control subjects. Individuals with TKR demonstrate increased flexor muscle activation during weight bearing, potentially contributing to altered gait patterns found during the stance phase of gait. The RAI helps detail whether decreased external moments correspond to less agonist or more antagonist muscle activity to determine true muscle activity differences between subject groups. Identifying the mechanisms underlying altered muscle function both before and after TKR is critical for developing rehabilitation strategies to address functional deficits and disability found in this patient population. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Physical activity and experience of total knee replacement in patients one to four years postsurgery in the dominican republic: a qualitative study.

    PubMed

    Stenquist, Derek S; Elman, Scott A; Davis, Aileen M; Bogart, Laura M; Brownlee, Sarah A; Sanchez, Edward S; Santiago, Adianez; Ghazinouri, Roya; Katz, Jeffrey N

    2015-01-01

    Musculoskeletal disorders are the second leading cause of years lived with disability globally. Total knee replacement (TKR) offers patients with advanced arthritis relief from pain and the opportunity to return to physical activity. We investigated the impact of TKR on physical activity for patients in a developing nation. As part of the Operation Walk Boston surgical mission program, we interviewed 18 Dominican patients (78% women) who received TKR about their level of physical activity after surgery. Qualitative interviews were conducted in Spanish, and English transcripts were analyzed using content analysis. Most patients found that TKR increased their participation in physical activities in several life domains, such as occupational or social pursuits. Some patients limited their own physical activities due to uncertainty about medically appropriate levels of joint use and postoperative physical activity. Many patients noted positive effects of TKR on mood and mental health. For most patients in the study, religion offered a framework for understanding their receipt of and experience with TKR. Our findings underscore the potential of TKR to permit patients in the developing world to return to physical activities. This research also demonstrates the influence of patients' education, culture, and religion on patients' return to physical activity. As the global burden of musculoskeletal disease increases, it is important to characterize the impact of activity limitation on patients' lives in diverse settings and the potential for surgical intervention to ease the burden of chronic arthritis. Copyright © 2015 by the American College of Rheumatology.

  20. Total Knee Replacement

    PubMed Central

    2005-01-01

    Executive Summary Objective The aim of this review was to assess the effectiveness, in terms of pain reduction and functional improvement, and costing of total knee replacement (TKR) for people with osteoarthritis for whom less invasive treatments (such as physiotherapy, analgesics, anti-inflammatory drugs, intra-articular steroids, hyaluronic acids, and arthroscopic surgery) have failed. Clinical Need Osteoarthritis affects an estimated 10% to 12% of Canadian adults. The therapeutic goals of osteoarthritis treatment are to improve joint mobility and reduce pain. Stepwise treatment options include exercise, weight loss, physiotherapy, analgesics, anti-inflammatory drugs, intra-articular steroids and hyaluronic acids, arthroscopic surgery, and, in severe cases, total joint replacement with follow-up rehabilitation. These treatments are delivered by a range of health care professionals, including physiotherapists, occupational therapists, family physicians, internists, rheumatologists, and orthopedic surgeons. TKR is an end-of-line treatment for patients with severe pain and functional limitations. More women than men undergo knee replacement, and most patients are between 55 and 84 years old. The Technology TKR is a surgical procedure in which an artificial joint or prosthesis replaces a damaged knee joint. The primary indication for TKR is pain, followed by functional limitation. Usually, a person’s daily activities must be substantially affected by pain and functional limitations for him or her to be considered a candidate for TKR. There are 3 different types of knee replacement prostheses. Non-constrained prostheses use the patient’s ligaments and muscles to provide the stability for the prosthesis. Semi-constrained prostheses provide some stability for the knee and do not rely entirely on the patient’s ligaments and muscles to provide the stability. Constrained prostheses are for patients whose ligaments and muscles are not able to provide stability for the knee prosthesis. The most common risks and complications associated with TKR are deep venous thrombosis, infection, stiffness, loosening, and osteolysis. To prevent deep venous thrombosis, patients are treated with heparin prophylactically and/or given support stockings to wear. Patients are also given antibiotics for 24 hours after surgery to minimize the risk of infection. Stiffness is another associated complication. In most patients, it can be avoided by keeping the knee moving in the days and weeks following surgery. The National Institutes of Health in the United States concluded that the indications for TKR should include the following: radiological evidence of joint damage, moderate to severe persistent pain that is not adequately relieved by nonsurgical management, and clinically significant functional limitation resulting in diminished quality of life. Review Strategy In March 2005, the following databases were searched: Cochrane Library International Agency for Health Technology Assessment (first quarter 2005), Cochrane Database of Systematic Reviews (first quarter 2005), Cochrane Central Register of Controlled Trials (first quarter 2005), MEDLINE (1966 to March 2005), MEDLINE In-Process and Other Non-indexed Citations (1966 to March 14, 2005), and EMBASE (1980 to 2005 week 9). The Medical Advisory Secretariat also searched Medscape on the Internet for recent reports on trials that were unpublished but that were presented at international conferences. In addition, the Web site Current Controlled Trials (www.controlled-trials.com) was searched for ongoing trials investigating TKR or unicompartmental knee replacement. No studies were identified that compared TKR to an alternative treatment. Several studies have been reported that compare preoperative measurement scores on targeted measures of functioning and pain to postoperative measurement scores in patients undergoing various TKR procedures. In order for the Medical Advisory Secretariat to measure the effectiveness of TKR and to compare the effectiveness of TKR across studies, effect sizes were calculated in studies that reported the standard deviations of the preoperative and postoperative measurement scores. Percent change was also calculated. For this review, a 20% improvement in outcome score was defined as the minimal clinically important difference. Summary of Findings Overall, patients who undergo TKR surgery for osteoarthritis have substantial improvements in terms of reduction of pain and improvement of function. A comparison of the mean effect score and the percent change in 19 studies that reported preoperative and postoperative outcome scores for patients who had TKR showed that the procedure is effective. The 19 studies included patients of various ages and used a variety of prostheses and techniques to implant the device. TKR was effective in all of the studies. The revision rates ranged from 0% to 13% in the studies that reported at least 5 years of follow-up. As for the factors that predict TKR outcomes, a variety of factors have been evaluated, including obesity, age, gender, prosthesis design, and surgical techniques; however, none of these have been shown to predict outcomes (pain or function) consistently across studies. However, the regression analyses identified accounted for only 12% to 27% of the variance, indicating that over 70% of the variance in the outcomes of TKR is unexplained. In terms of the timing of TKR surgery, 2 studies found that the severity of osteoarthritis does not predict outcome, but 1 study was found that higher functioning patients had significantly less pain and better function up to 2 years after surgery compared with lower functioning patients. It is important to note that the patients in the low and high function groups were evenly matched on comorbid conditions. Unicompartmental knee replacement surgery seems to be as effective as TKR surgery for people who meet the indications for it. This is a subset of people who have osteoarthritis of the knee, because for unicompartmental knee replacement to be indicated, only 1 (usually the medial) compartment of the knee can be affected. Patients who undergo this kind of surgery seem to have shorter hospital stays and faster recovery times than do patients who have TKR surgery. Conclusion There is substantial evidence to indicate that TKR effectively reduces pain and improves function. PMID:23074478

  1. Development and Testing of the AMEGO Silicon Tracker System

    NASA Astrophysics Data System (ADS)

    Griffin, Sean; Amego Team

    2018-01-01

    The All-sky Medium Energy Gamma-ray Observatory (AMEGO) is a probe-class mission in consideration for the 2020 decadal review designed to operate at energies from ˜ 200 keV to > 10 GeV. Operating a detector in this energy regime is challenging due to the crossover in the interaction cross-section for Compton scattering and pair production. AMEGO is made of four major subsystems: a plastic anticoincidence detector for rejecting cosmic-ray events, a silicon tracker for measuring the energies of Compton scattered electrons and pair-production products, a CZT calorimeter for measuring the energy and location of Compton scattered photons, and a CsI calorimeter for measuring the energy of the pair-production products at high energies. The tracker comprises layers of dual-sided silicon strip detectors which provide energy and localization information for Compton scattering and pair-production events. A prototype tracker system is under development at GSFC; in this contribution we provide details on the verification, packaging, and testing of the prototype tracker, as well as present plans for the development of the front-end electronics, beam tests, and a balloon flight.

  2. Manipulation under anaesthesia post total knee replacement: long term follow up.

    PubMed

    Yeoh, David; Nicolaou, Nick; Goddard, Richard; Willmott, Henry; Miles, Kim; East, Debra; Hinves, Barry; Shepperd, John; Butler-Manuel, Adrian

    2012-08-01

    A reduced range of motion post total knee replacement (TKR) is a recognised problem. Manipulation under anaesthesia (MUA) is commonly performed in the stiff post-operative TKR. Long-term results are variable in the literature. We retrospectively reviewed, prospectively collected data on 48 patients followed up since 1996 from one centre, over an average of 7.5 years, (range 1 to 10 years) and report on the long-term results. During the study period 2.3% of TKRs underwent MUA. The mean time to MUA post TKR was 12.3 weeks (range 3 to 48). Pre MUA, the mean flexion was 53°. The mean immediate passive flexion post MUA was 97°, an improvement of 44° (Range 10° to 90°, p<0.05). By 1year, the mean flexion was 87°, an improvement of 34°, (range -15° to 70°, p<0.05). At 10 years the mean flexion was 86°, (range 55° to 100°, p<0.05). We found no difference in the gain in range of motion (ROM) between knees manipulated before or after 12 weeks. Additionally, the gain was no different in stiff knees with a pre TKR ROM <90°, compared to a pre TKR ROM >90°. There were no complications as a result of MUA. However, one patient was eventually revised at 2 years secondary to low grade infection. Our findings show that MUA is a safe and effective method at improving the ROM in a stiff post-operative TKR. The improvement is maintained in the long term irrespective of time to MUA and range of motion pre TKR. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  3. Cost utility modeling of early vs late total knee replacement in osteoarthritis patients.

    PubMed

    Mari, K; Dégieux, P; Mistretta, F; Guillemin, F; Richette, P

    2016-12-01

    Given the dramatic increase in the number of total knee replacement (TKR) surgeries in developed countries, the issue of the best time for surgery needs to be addressed from an economic perspective. To assess, from the perspective of the healthcare payer, the cost-utility of two surgical strategies in which knee replacement is performed at the early or late stage of the disease in patients with knee osteoarthritis (OA). Patient data and evidence from published literature on economic costs and outcomes in OA, including utilities, non-pharmacological, pharmacological and surgical options, combined with population life tables were entered in a Markov model of OA. The model represented the lifetime experience of a cohort of patients following their therapeutic management, discounting costs (euros) and utilities (quality-adjusted life-years) at 4% annually. In the base-case scenario, early TKR cost €6,624 more than late TKR (€76,223 vs €69,599) with a 0.15 gain in QALYs (18.675 vs 18.524). This yielded an incremental cost-utility ratio (ICUR) of 43,631 €/QALY. Sensitivity analyses of the most influential uncertain parameters were performed and did not modify the direction of the conclusions: early TKR cost between €3,655 and €7,194 more than late TKR with a gain in QALYs between 0.15 and 0.39. The ICUR ranged from 17,131 €/QALY to 48,241 €/QALY. Our data do not support the early TKR strategy over the late TKR strategy in knee OA patients from a medico-economic perspective. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  4. RSA migration of total knee replacements.

    PubMed

    Pijls, Bart G; Plevier, José W M; Nelissen, Rob G H H

    2018-06-01

    Purpose - We performed a systematic review and meta-analyses to evaluate the early and long-term migration patterns of tibial components of TKR of all known RSA studies. Methods - Migration pattern was defined as at least 2 postoperative RSA follow-up moments. Maximal total point motion (MTPM) at 6 weeks, 3 months, 6 months, 1 year, 2 years, 5 years, and 10 years were considered. Results - The literature search yielded 1,167 hits of which 53 studies were included, comprising 111 study groups and 2,470 knees. The majority of the early migration occurred in the first 6 months postoperatively followed by a period of stability, i.e., no or very little migration. Cemented and uncemented tibial components had different migration patterns. For cemented tibial components there was no difference in migration between all-poly and metal-backed components, between mobile bearing and fixed bearing, between cruciate retaining and posterior stabilized. Furthermore, no difference existed between TKR measured with model-based RSA or marker-based RSA methods. For uncemented TKR there was some variation in migration with the highest migration for uncoated TKR. Interpretation - The results from this meta-analysis on RSA migration of TKR are in line with both the survival analyses results from joint registries of these TKRs as well as revision rates results from meta-analyses, thus providing further proof for the association between early migration and late revision for loosening. The pooled migration patterns can be used both as benchmarks and for defining migration thresholds for future evaluation of new TKR.

  5. What Is the Role of Nutritional Supplements in Support of Total Hip Replacement and Total Knee Replacement Surgeries? A Systematic Review.

    PubMed

    Burgess, Louise C; Phillips, Stuart M; Wainwright, Thomas W

    2018-06-25

    Nutritional supplements can influence outcomes for individuals undergoing major surgery, particularly in older persons whose functional reserve is limited. Accelerating recovery from total hip replacement (THR) and total knee replacement (TKR) may offer significant benefits. Therefore, we explored the role of nutritional supplements in improving recovery following THR and TKR. A systematic review was conducted to source randomized clinical trials that tested nutritional supplements in cohorts of THR or TKR patients. Our search yielded nine relevant trials. Intake of a carbohydrate-containing fluid is reported to improve insulin-like growth factor levels, reduce hunger, nausea, and length of stay, and attenuate the decrease in whole-body insulin sensitivity and endogenous glucose release. Amino acid supplementation is reported to reduce muscle atrophy and accelerate return of functional mobility. One paper reported a suppressive effect of beta-hydroxy beta-methylbutyrate, L-arginine, and L-glutamine supplementation on muscle strength loss following TKR. There is limited evidence for nutritional supplementation in THR and TKR pathways; however, the low risk profile and potential benefits to adjunctive treatment methods, such as exercise programs, suggest nutritional supplements may have a role. Optimizing nutritional status pre-operatively may help manage the surgical stress response, with a particular benefit for undernourished, frail, or elderly individuals.

  6. Cemented total knee replacement in 24 dogs: surgical technique, clinical results, and complications.

    PubMed

    Allen, Matthew J; Leone, Kendall A; Lamonte, Kimberly; Townsend, Katy L; Mann, Kenneth A

    2009-07-01

    To characterize the performance of cemented total knee replacement (TKR) in dogs. Preclinical research study. Skeletally mature, male Hounds (25-30 kg; n=24) with no preexisting joint pathology. Dogs had unilateral cemented TKR and were evaluated at 6, 12, 26, or 52 weeks (6 dogs/time point) by radiography, bone density analysis, visual gait assessment, and direct measurement of thigh circumference and stifle joint range of motion as indicators of functional recovery. At study end, the stability of the cemented tibial component was determined by destructive mechanical testing. Joint stability was excellent in 16 dogs (67%) and good in 8 dogs. None of the tibial components had evidence of migration or periprosthetic osteolysis whereas 1 femoral component was loose at 52 weeks. There was an early and significant decrease in tibial bone density, likely because of disuse of the operated limb. Dogs returned to full activity by 12 weeks. The tibial cement-bone interface maintained its strength over 52 weeks. Cement provides stable fixation of the tibial component in canine TKR. Cemented TKR yields adequate clinical function and stifle joint excursion in the dog. Clinical studies are needed to determine the long-term fate of cemented TKR implants, to assess the influence of implant design on implant fixation and wear, and to obtain objective functional data.

  7. Sick leave in Sweden before and after total joint replacement in hip and knee osteoarthritis patients.

    PubMed

    Stigmar, Kjerstin; Dahlberg, Leif E; Zhou, Caddie; Jacobson Lidgren, Helena; Petersson, Ingemar F; Englund, Martin

    2017-04-01

    Background and purpose - Little is know about patterns of sick leave in connection with total hip and knee joint replacement (THR and TKR) in patients with osteoarthritis (OA). Patients and methods - Using registers from southern Sweden, we identified hip and knee OA patients aged 40-59 years who had a THR or TKR in the period 2004-2012. Patients who died or started on disability pension were excluded. We included 1,307 patients with THR (46% women) and 996 patients with TKR (56% women). For the period 1 year before until 2 years after the surgery, we linked individual-level data on sick leave from the Swedish Social Insurance Agency. We created a matched reference cohort from the general population by age, birth year, and area of residence (THR: n = 4,604; TKR: n = 3,425). The mean number of days on sick leave and the proportion (%) on sick leave 12 and 24 months before and after surgery were calculated. Results - The month after surgery, about 90% of patients in both cohorts were on sick leave. At the two-year follow-up, sick leave was lower for both cohorts than 1 year before surgery, except for men with THR, but about 9% of the THR patients and 12-17% of the TKR patients were still sick-listed. In the matched reference cohorts, sick leave was constant at around 4-7% during the entire study period. Interpretation - A long period of sick leave is common after total joint replacement, especially after TKR. There is a need for better knowledge on how workplace adjustments and rehabilitation can facilitate the return to work and can postpone surgery.

  8. The relationship between three-dimensional knee MRI bone shape and total knee replacement—a case control study: data from the Osteoarthritis Initiative

    PubMed Central

    Barr, Andrew J.; Dube, Bright; Hensor, Elizabeth M. A.; Kingsbury, Sarah R.; Peat, George; Bowes, Mike A.; Sharples, Linda D.

    2016-01-01

    Objective. There is growing understanding of the importance of bone in OA. Our aim was to determine the relationship between 3D MRI bone shape and total knee replacement (TKR). Methods. A nested case-control study within the Osteoarthritis Initiative cohort identified case knees with confirmed TKR for OA and controls that were matched using propensity scores. Active appearance modelling quantification of the bone shape of all knee bones identified vectors between knees having or not having OA. Vectors were scaled such that −1 and +1 represented the mean non-OA and mean OA shapes. Results. Compared to controls (n = 310), TKR cases (n = 310) had a more positive mean baseline 3D bone shape vector, indicating more advanced structural OA, for the femur [mean 0.98 vs −0.11; difference (95% CI) 1.10 (0.88, 1.31)], tibia [mean 0.86 vs −0.07; difference (95% CI) 0.94 (0.72, 1.16)] and patella [mean 0.95 vs 0.03; difference (95% CI) 0.92 (0.65, 1.20)]. Odds ratios (95% CI) for TKR per normalized unit of 3D bone shape vector for the femur, tibia and patella were: 1.85 (1.59, 2.16), 1.64 (1.42, 1.89) and 1.36 (1.22, 1.50), respectively, all P < 0.001. After including Kellgren–Lawrence grade in a multivariable analysis, only the femur 3D shape vector remained significantly associated with TKR [odds ratio 1.24 (1.02, 1.51)]. Conclusion. 3D bone shape was associated with the endpoint of this study, TKR, with femoral shape being most associated. This study contributes to the validation of quantitative MRI bone biomarkers for OA structure-modification trials. PMID:27185958

  9. Prospective associations of C-reactive protein (CRP) levels and CRP genetic risk scores with risk of total knee and hip replacement for osteoarthritis in a diverse cohort.

    PubMed

    Shadyab, A H; Terkeltaub, R; Kooperberg, C; Reiner, A; Eaton, C B; Jackson, R D; Krok-Schoen, J L; Salem, R M; LaCroix, A Z

    2018-05-22

    To examine associations of high-sensitivity C-reactive protein (CRP) levels and polygenic CRP genetic risk scores (GRS) with risk of end-stage hip or knee osteoarthritis (OA), defined as incident total hip (THR) or knee replacement (TKR) for OA. This study included a cohort of postmenopausal white, African American, and Hispanic women from the Women's Health Initiative. Women were followed from baseline to date of THR or TKR, death, or December 31, 2014. Medicare claims data identified THR and TKR. Hs-CRP and genotyping data were collected at baseline. Three CRP GRS were constructed: 1) a 4-SNP GRS comprised of genetic variants representing variation in the CRP gene among European populations; 2) a multilocus 18-SNP GRS of genetic variants significantly associated with CRP levels in a meta-analysis of genome-wide association studies; and 3) a 5-SNP GRS of genetic variants significantly associated with CRP levels among African American women. In analyses conducted separately among each race and ethnic group, there were no significant associations of ln hs-CRP with risk of THR or TKR, after adjusting for age, body mass index, lifestyle characteristics, chronic diseases, hormone therapy use, and non-steroidal anti-inflammatory drug use. CRP GRS were not associated with risk of THR or TKR in any ethnic group. Serum levels of ln hs-CRP and genetically-predicted CRP levels were not associated with risk of THR or TKR for OA among a diverse cohort of women. Copyright © 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Mobile assessment of the lower limb kinematics in healthy persons and in persons with degenerative knee disorders: A systematic review.

    PubMed

    van der Straaten, R; De Baets, L; Jonkers, I; Timmermans, A

    2018-01-01

    Inertial sensor systems are increasingly used in the assessment of persons with knee osteoarthritis (KOA) and total knee replacement (TKR). This systematic review aims to (1) investigate the application of inertial sensor systems and kinematics derived from these systems, and (2) assess if current assessment protocols consist of tasks which are, according to the International Classification of Functioning, Disability and Health (ICF) for KOA, relevant for persons with KOA and TKR. A search was conducted in six electronic databases (ACM, CINAHL, EMBASE, IEEE, PubMed, Web of Science) to include papers assessing the knee and one or more adjacent joints by means of inertial sensors in healthy persons or persons with KOA or TKR. Two reviewers checked the methodological quality. Twenty-three papers were included: 18 in healthy persons and five in persons with KOA or TKR. In healthy persons, 11 tasks were related to metrics of the ICF-function and ICF-activity level. In persons with KOA, only walking was assessed. Apart from walking, four additional tasks were related to the ICF-function and ICF-activity level in persons with TKR. In healthy persons, joints located proximally and distally to the knee were assessed, while in persons with KOA and TKR, only the knee and ankle were assessed. This is a shortcoming since hip and trunk motion potentially contain clinically relevant information, in terms of identifying (mal)adaptive compensatory movement strategies. Additionally, physically more demanding tasks should be evaluated as these might be superior in detecting compensatory movement strategies. Former considerations warrant attention in future research. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

    PubMed

    Smith, Colin R; Vignos, Michael F; Lenhart, Rachel L; Kaiser, Jarred; Thelen, Darryl G

    2016-02-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.

  12. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    PubMed Central

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial–lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and −23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement. PMID:26769446

  13. Right TKR Patients Treated with Enhanced Pain and Rehabilitation Protocols Can Drive at 2 Weeks.

    PubMed

    Dalury, David F; Chapman, Danielle M

    2018-06-20

    An important milestone in the recovery following total knee replacement (TKR) is the ability to return to driving. With advances in pain control and the widespread introduction of rapid rehab programs, we hypothesized that the ability to drive would also return sooner than had been traditionally observed. In our group of consecutive right TKR patients, using a driving simulator, we showed that at the 2-week mark, 36 of the 40 patients tested had returned to their preoperative driving capabilities and the other 4 had reached baseline at 3 weeks. While the eventual decision to return to driving is complex and dependent on many factors, we conclude that one of the benefits of enhanced pain and rehab protocols is that patients undergoing right TKR can return to driving in most instances at the 2-week mark rather than the traditional 6-week mark. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Trends and determinants of length of stay and hospital reimbursement following knee and hip replacement: evidence from linked primary care and NHS hospital records from 1997 to 2014.

    PubMed

    Burn, Edward; Edwards, Christopher J; Murray, David W; Silman, Alan; Cooper, Cyrus; Arden, Nigel K; Pinedo-Villanueva, Rafael; Prieto-Alhambra, Daniel

    2018-01-27

    To measure changes in length of stay following total knee and hip replacement (TKR and THR) between 1997 and 2014 and estimate the impact on hospital reimbursement, all else being equal. Further, to assess the degree to which observed trends can be explained by improved efficiency or changes in patient profiles. Cross-sectional study using routinely collected data. National Health Service primary care records from 1995 to 2014 in the Clinical Practice Research Datalink were linked to hospital inpatient data from 1997 to 2014 in Hospital Episode Statistics Admitted Patient Care. Study participants had a diagnosis of osteoarthritis or rheumatoid arthritis. Primary TKR, primary THR, revision TKR and revision THR. Length of stay and hospital reimbursement. 10 260 primary TKR, 10 961 primary THR, 505 revision TKR and 633 revision THR were included. Expected length of stay fell from 16.0 days (95% CI 14.9 to 17.2) in 1997 to 5.4 (5.2 to 5.6) in 2014 for primary TKR and from 14.4 (13.7 to 15.0) to 5.6 (5.4 to 5.8) for primary THR, leading to savings of £1537 and £1412, respectively. Length of stay fell from 29.8 (17.5 to 50.5) to 11.0 (8.3 to 14.6) for revision TKR and from 18.3 (11.6 to 28.9) to 12.5 (9.3 to 16.8) for revision THR, but no significant reduction in reimbursement was estimated. The estimated effect of year of surgery remained similar when patient characteristics were included. Length of stay for joint replacement fell substantially from 1997 to 2014. These reductions have translated into substantial savings. While patient characteristics affect length of stay and reimbursement, patient profiles have remained broadly stable over time. The observed reductions appear to be mostly explained by improved efficiency. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Cost-effectiveness of unicompartmental compared with total knee replacement: a population-based study using data from the National Joint Registry for England and Wales

    PubMed Central

    Liddle, Alexander D; Hamilton, Thomas W; Judge, Andrew; Pandit, Hemant G; Murray, David W; Pinedo-Villanueva, Rafael

    2018-01-01

    Objectives To assess the value for money of unicompartmental knee replacement (UKR) compared with total knee replacement (TKR). Design A lifetime Markov model provided the framework for the analysis. Setting Data from the National Joint Registry (NJR) for England and Wales primarily informed the analysis. Participants Propensity score matched patients in the NJR who received either a UKR or TKR. Interventions UKR is a less invasive alternative to TKR, where only the compartment affected by osteoarthritis is replaced. Primary outcome measures Incremental quality-adjusted life years (QALYs) and healthcare system costs. Results The provision of UKR is expected to lead to a gain in QALYs compared with TKR for all age and gender subgroups (male: <60 years: 0.12, 60–75 years: 0.20, 75+ years: 0.19; female: <60 years: 0.10, 60–75 years: 0.28, 75+ years: 0.44) and a reduction in costs (male: <60: £−1223, 60–75 years: £−1355, 75+ years: £−2005; female: <60 years: £−601, 60–75 years: £−935, 75+ years: £−1102 per patient over the lifetime). UKR is expected to lead to a reduction in QALYs compared with TKR when performed by surgeons with low UKR utilisation but an increase among those with high utilisation (<10%, median 6%: −0.04, ≥10%, median 27%: 0.26). Regardless of surgeon usage, costs associated with UKR are expected to be lower than those of TKR (<10%: £−127, ≥10%: £−758). Conclusions UKR can be expected to generate better health outcomes and lower lifetime costs than TKR. Surgeon usage of UKR does, however, have a significant impact on the cost-effectiveness of the procedure. To achieve the best results, surgeons need to perform a sufficient proportion of knee replacements as UKR. Low usage surgeons may therefore need to broaden their indications for UKR. PMID:29706598

  16. Metabolic syndrome as a risk factor for total hip or knee replacement due to primary osteoarthritis: a prospective cohort study (the HUNT study and the Norwegian Arthroplasty Register)

    PubMed Central

    Hellevik, Alf Inge; Johnsen, Marianne Bakke; Langhammer, Arnulf; Baste, Valborg; Furnes, Ove; Storheim, Kjersti; Zwart, John Anker; Flugsrud, Gunnar Birkeland; Nordsletten, Lars

    2018-01-01

    Objective Biochemical changes associated with obesity may accelerate osteoarthritis beyond the effect of mechanical factors. This study investigated whether metabolic syndrome and its components (visceral obesity, hypertension, dyslipidemia and insulin resistance) were risk factors for subsequent total hip replacement (THR) or total knee replacement (TKR) due to primary osteoarthritis. Design In this prospective cohort study, data from the second survey of the Nord-Trøndelag Health Study 2 (HUNT2) were linked to the Norwegian Arthroplasty Register for identification of the outcome of THR or TKR. The analyses were stratified by age (<50, 50–69.9 and ≥70 years) and adjusted for gender, body mass index, smoking, physical activity and education. Results Of the 62,661 participants, 12,593 (20.1%) were identified as having metabolic syndrome, and we recorded 1,840 (2.9%) THRs and 1,111 (1.8%) TKRs during a mean follow-up time of 15.4 years. Cox regression analyses did not show any association between full metabolic syndrome and THR or TKR, except in persons <50 years with metabolic syndrome who had a decreased risk of THR (hazard ratio [HR] 0.58, 95% CI 0.40–0.83). However, when including only participants whose exposure status did not change during follow-up, this protective association was no longer significant. Increased waist circumference was associated with increased risk of TKR in participants <50 years (HR 1.62, 95% CI 1.10–2.39) and 50–69.9 years (HR 1.43, 95% CI 1.14–1.80). Hypertension significantly increased the risk of TKR in participants <50 years (HR 1.38, 95% CI 1.05–1.81), and this risk was greater for men. Conclusion This study found an increased risk of TKR in men <50 years with hypertension and persons <70 years with increased waist circumference. Apart from this, neither metabolic syndrome nor its components were associated with increased risk of THR or TKR due to primary osteoarthritis. PMID:29391831

  17. Metabolic syndrome as a risk factor for total hip or knee replacement due to primary osteoarthritis: a prospective cohort study (the HUNT study and the Norwegian Arthroplasty Register).

    PubMed

    Hellevik, Alf Inge; Johnsen, Marianne Bakke; Langhammer, Arnulf; Baste, Valborg; Furnes, Ove; Storheim, Kjersti; Zwart, John Anker; Flugsrud, Gunnar Birkeland; Nordsletten, Lars

    2018-01-01

    Biochemical changes associated with obesity may accelerate osteoarthritis beyond the effect of mechanical factors. This study investigated whether metabolic syndrome and its components (visceral obesity, hypertension, dyslipidemia and insulin resistance) were risk factors for subsequent total hip replacement (THR) or total knee replacement (TKR) due to primary osteoarthritis. In this prospective cohort study, data from the second survey of the Nord-Trøndelag Health Study 2 (HUNT2) were linked to the Norwegian Arthroplasty Register for identification of the outcome of THR or TKR. The analyses were stratified by age (<50, 50-69.9 and ≥70 years) and adjusted for gender, body mass index, smoking, physical activity and education. Of the 62,661 participants, 12,593 (20.1%) were identified as having metabolic syndrome, and we recorded 1,840 (2.9%) THRs and 1,111 (1.8%) TKRs during a mean follow-up time of 15.4 years. Cox regression analyses did not show any association between full metabolic syndrome and THR or TKR, except in persons <50 years with metabolic syndrome who had a decreased risk of THR (hazard ratio [HR] 0.58, 95% CI 0.40-0.83). However, when including only participants whose exposure status did not change during follow-up, this protective association was no longer significant. Increased waist circumference was associated with increased risk of TKR in participants <50 years (HR 1.62, 95% CI 1.10-2.39) and 50-69.9 years (HR 1.43, 95% CI 1.14-1.80). Hypertension significantly increased the risk of TKR in participants <50 years (HR 1.38, 95% CI 1.05-1.81), and this risk was greater for men. This study found an increased risk of TKR in men <50 years with hypertension and persons <70 years with increased waist circumference. Apart from this, neither metabolic syndrome nor its components were associated with increased risk of THR or TKR due to primary osteoarthritis.

  18. Leisure time physical activity and the risk of hip or knee replacement due to primary osteoarthritis: a population based cohort study (The HUNT Study).

    PubMed

    Johnsen, Marianne Bakke; Hellevik, Alf Inge; Baste, Valborg; Furnes, Ove; Langhammer, Arnulf; Flugsrud, Gunnar; Nordsletten, Lars; Zwart, John Anker; Storheim, Kjersti

    2016-02-16

    The relationship between leisure time physical activity (LPA) and hip and knee OA and subsequent joint replacement has not yet been clearly defined. Some studies have found the risk of knee replacement (TKR) to increase with high levels of LPA, while others have found no overall relationship to either TKR or hip replacement (THR). The aim was to investigate the association between LPA and the risk of severe end-stage OA, defined as THR or TKR due to primary OA, in a large population-based cohort. Participants in the Nord-Trøndelag Health Study (HUNT) were followed prospectively to identify THR and TKR using the Norwegian Arthroplasty Register. Self-reported LPA was classified as inactive, low, moderate or high. The Cox proportional hazards model was used to calculate hazard ratios (HRs) according to levels of LPA with adjustments for confounding variables. Analyses were performed by age (<45, 45-59 and ≥60 years) and sex. A total of 66 964 participants (mean age 46.8 years (SD 16.3) were included in the analyses. We identified 1636 THRs and 1016 TKRs due to primary OA during 17.0 years (median) of follow-up. High LPA was significantly associated with THR for women <45 years (HR 1.78, 95 % CI 1.08-2.94) and men between 45-59 years (HR 1.53, 95 % CI 1.10-2.13) at baseline. A significant trend was found only among women < 45 years at baseline (p = 0.02). We found that LPA was significantly associated with TKR for women only (HR 1.45, 95 % CI 1.03-2.04). No measures of LPA were associated with TKR for men. In this population-based study, high level of LPA was associated with increased risk of THR where a significant trend of LPA was seen among women <45 years at baseline. For TKR, high LPA was associated with increased risk only in women. In contrast to previous studies, this study shows a possible association between high LPA and the risk of THR.

  19. Posterior stability in fixed-bearing versus mobile-bearing total knee replacement: a radiological comparison of two implants.

    PubMed

    Siebold, R; Louisia, S; Canty, J; Bartlett, R J

    2007-02-01

    Posterior tibial translation in total knee replacement (TKR) could be one major factor for PE wear, delamination and loosening of the tibial component due to increased shear forces and component-to-bone interface stress. The aim of this study was to assess the posterior stability of two different designs of posterior cruciate ligament (PCL) substituting TKR. In this non-randomised consecutive study 43 patients underwent TKR for primary osteoarthritis. Twenty-six patients in group FB received a deep-dished fixed-bearing Duracon TKR (Howmedica, Rutherford, NJ, USA) and 17 patients in group MB a deep-dished rotating mobile-bearing Duracon TKR. In both groups the PCL was resected. All patients had pre- and postoperative kneeling stress radiographs and were clinically evaluated with the Knee Society Score. Posterior tibial translation was measured by tracing a line along the posterior tibial cortex in relationship to the posterior edge of Blumensaat's line. The average follow-up was 13 months for group FB and 11 months for group MB. Both groups demonstrated a statistical significant increase of the mean posterior tibial translation on kneeling stress X-ray of 4.1 mm (group FB) (P < 0.001) and of 6.6 mm (group MB) (P < 0.001) compared to pre-operative. Group MB showed a significant higher posterior draw (P < 0.008). Clinical assessment using the Knee Society Score showed comparable short-term results. The deep-dished fixed-bearing TKR as well as the deep-dished rotating mobile-bearing TKR demonstrated significant posterior tibial translation on kneeling stress X-ray. It remains to be determined what amount of joint play is optimal for clinical function and to minimise shear forces and PE wear. Moreover the amount of posterior tibial translation was significantly higher with the mobile-bearing insert, which could be directly related to the asymmetric rotational mobility of the tibial insert. A long-term follow-up is necessary to investigate whether our findings correlate with the survival-rate of these specific implants.

  20. Incidence of hip and knee replacement in patients with rheumatoid arthritis following the introduction of biological DMARDs: an interrupted time-series analysis using nationwide Danish healthcare registers.

    PubMed

    Cordtz, René Lindholm; Hawley, Samuel; Prieto-Alhambra, Daniel; Højgaard, Pil; Zobbe, Kristian; Overgaard, Søren; Odgaard, Anders; Kristensen, Lars Erik; Dreyer, Lene

    2018-05-01

    To study the impact of the introduction of biological disease-modifying anti-rheumatic drugs (bDMARDs) and associated rheumatoid arthritis (RA) management guidelines on the incidence of total hip (THR) and knee replacements (TKR) in Denmark. Nationwide register-based cohort and interrupted time-series analysis. Patients with incident RA between 1996 and 2011 were identified in the Danish National Patient Register. Patients with RA were matched on age, sex and municipality with up to 10 general population comparators (GPCs). Standardised 5-year incidence rates of THR and TKR per 1000 person-years were calculated for patients with RA and GPCs in 6-month periods. Levels and trends in the pre-bDMARD (1996-2001) were compared with the bDMARD era (2003-2016) using segmented linear regression interrupted by a 1-year lag period (2002). We identified 30 404 patients with incident RA and 297 916 GPCs. In 1996, the incidence rate of THR and TKR was 8.72 and 5.87, respectively, among patients with RA, and 2.89 and 0.42 in GPCs. From 1996 to 2016, the incidence rate of THR decreased among patients with RA, but increased among GPCs. Among patients with RA, the incidence rate of TKR increased from 1996 to 2001, but started to decrease from 2003 and throughout the bDMARD era. The incidence of TKR increased among GPCs from 1996 to 2016. We report that the incidence rate of THR and TKR was 3-fold and 14-fold higher, respectively among patients with RA compared with GPCs in 1996. In patients with RA, introduction of bDMARDs was associated with a decreasing incidence rate of TKR, whereas the incidence of THR had started to decrease before bDMARD introduction. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. An evidence-based review of enhanced recovery interventions in knee replacement surgery

    PubMed Central

    Alazzawi, S; Nizam, I; Haddad, FS

    2013-01-01

    Introduction Total knee replacement (TKR) is a very common surgical procedure. Improved pain management techniques, surgical practices and the introduction of novel interventions have enhanced the patient’s postoperative experience after TKR. Safe, efficient pathways are needed to address the increasing need for knee arthroplasty in the UK. Enhanced recovery programmes can help to reduce hospital stays following knee replacements while maintaining patient safety and satisfaction. This review outlines common evidence-based pre, intra and postoperative interventions in use in enhanced recovery protocols following TKR. Methods A thorough literature search of the electronic healthcare databases (MEDLINE®, Embase™ and the Cochrane Library) was conducted to identify articles and studies concerned with enhanced recovery and fast track pathways for TKR. Results A literature review revealed several non-operative and operative interventions that are effective in enhanced recovery following TKR including preoperative patient education, pre-emptive and local infiltration analgesia, preoperative nutrition, neuromuscular electrical stimulation, pulsed electromagnetic fields, perioperative rehabilitation, modern wound dressings, different standard surgical techniques, minimally invasive surgery and computer assisted surgery. Conclusions Enhanced recovery programmes require a multidisciplinary team of dedicated professionals, principally involving preoperative education, multimodal pain control and accelerated rehabilitation; this will be boosted if combined with minimally invasive surgery. The current economic climate and restricted healthcare budget further necessitate brief hospitalisation while minimising costs. These non-operative interventions are the way forward to achieve such requirements. PMID:24025284

  2. An evidence-based review of enhanced recovery interventions in knee replacement surgery.

    PubMed

    Ibrahim, M S; Alazzawi, S; Nizam, I; Haddad, F S

    2013-09-01

    Total knee replacement (TKR) is a very common surgical procedure. Improved pain management techniques, surgical practices and the introduction of novel interventions have enhanced the patient's postoperative experience after TKR. Safe, efficient pathways are needed to address the increasing need for knee arthroplasty in the UK. Enhanced recovery programmes can help to reduce hospital stays following knee replacements while maintaining patient safety and satisfaction. This review outlines common evidence-based pre, intra and postoperative interventions in use in enhanced recovery protocols following TKR. A thorough literature search of the electronic healthcare databases (MEDLINE(®), Embase™ and the Cochrane Library) was conducted to identify articles and studies concerned with enhanced recovery and fast track pathways for TKR. A literature review revealed several non-operative and operative interventions that are effective in enhanced recovery following TKR including preoperative patient education, pre-emptive and local infiltration analgesia, preoperative nutrition, neuromuscular electrical stimulation, pulsed electromagnetic fields, perioperative rehabilitation, modern wound dressings, different standard surgical techniques, minimally invasive surgery and computer assisted surgery. Enhanced recovery programmes require a multidisciplinary team of dedicated professionals, principally involving preoperative education, multimodal pain control and accelerated rehabilitation; this will be boosted if combined with minimally invasive surgery. The current economic climate and restricted healthcare budget further necessitate brief hospitalisation while minimising costs. These non-operative interventions are the way forward to achieve such requirements.

  3. The Impact of Regression to the Mean on Economic Evaluation in Quasi-Experimental Pre-Post Studies: The Example of Total Knee Replacement Using Data from the Osteoarthritis Initiative.

    PubMed

    Schilling, Chris; Petrie, Dennis; Dowsey, Michelle M; Choong, Peter F; Clarke, Philip

    2017-12-01

    Many treatments are evaluated using quasi-experimental pre-post studies susceptible to regression to the mean (RTM). Ignoring RTM could bias the economic evaluation. We investigated this issue using the contemporary example of total knee replacement (TKR), a common treatment for end-stage osteoarthritis of the knee. Data (n = 4796) were obtained from the Osteoarthritis Initiative database, a longitudinal observational study of osteoarthritis. TKR patients (n = 184) were matched to non-TKR patients, using propensity score matching on the predicted hazard of TKR and exact matching on osteoarthritis severity and health-related quality of life (HrQoL). The economic evaluation using the matched control group was compared to the standard method of using the pre-surgery score as the control. Matched controls were identified for 56% of the primary TKRs. The matched control HrQoL trajectory showed evidence of RTM accounting for a third of the estimated QALY gains from surgery using the pre-surgery HrQoL as the control. Incorporating RTM into the economic evaluation significantly reduced the estimated cost effectiveness of TKR and increased the uncertainty. A generalized ICER bias correction factor was derived to account for RTM in cost-effectiveness analysis. RTM should be considered in economic evaluations based on quasi-experimental pre-post studies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases

    PubMed Central

    Khemka, Aditya; Frossard, Laurent; Lord, Sarah J; Bosley, Belinda; Al Muderis, Munjed

    2015-01-01

    Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with transtibial amputation and knee arthritis. We report on the feasibility of combining total knee replacement (TKR) with an osseointegrated implant for prosthetic attachment. Patients and methods — We retrospectively reviewed all 4 cases (aged 38–77 years) of transtibial amputations managed with osseointegration and TKR in 2012–2014. The below-the-knee prosthesis was connected to the tibial base plate of a TKR, enabling the tibial residuum and knee joint to act as weight-sharing structures. A 2-stage procedure involved connecting a standard hinged TKR to custom-made implants and creation of a skin-implant interface. Clinical outcomes were assessed at baseline and after 1–3 years of follow-up using standard measures of health-related quality of life, ambulation, and activity level including the questionnaire for transfemoral amputees (Q-TFA) and the 6-minute walk test. Results — There were no major complications, and there was 1 case of superficial infection. All patients showed improved clinical outcomes, with a Q-TFA improvement range of 29–52 and a 6-minute walk test improvement range of 37–84 meters. Interpretation — It is possible to combine TKR with osseointegrated implants. PMID:26145721

  5. Validation of a prediction model that allows direct comparison of the Oxford Knee Score and American Knee Society clinical rating system.

    PubMed

    Maempel, J F; Clement, N D; Brenkel, I J; Walmsley, P J

    2015-04-01

    This study demonstrates a significant correlation between the American Knee Society (AKS) Clinical Rating System and the Oxford Knee Score (OKS) and provides a validated prediction tool to estimate score conversion. A total of 1022 patients were prospectively clinically assessed five years after TKR and completed AKS assessments and an OKS questionnaire. Multivariate regression analysis demonstrated significant correlations between OKS and the AKS knee and function scores but a stronger correlation (r = 0.68, p < 0.001) when using the sum of the AKS knee and function scores. Addition of body mass index and age (other statistically significant predictors of OKS) to the algorithm did not significantly increase the predictive value. The simple regression model was used to predict the OKS in a group of 236 patients who were clinically assessed nine to ten years after TKR using the AKS system. The predicted OKS was compared with actual OKS in the second group. Intra-class correlation demonstrated excellent reliability (r = 0.81, 95% confidence intervals 0.75 to 0.85) for the combined knee and function score when used to predict OKS. Our findings will facilitate comparison of outcome data from studies and registries using either the OKS or the AKS scores and may also be of value for those undertaking meta-analyses and systematic reviews. ©2015 The British Editorial Society of Bone & Joint Surgery.

  6. Return to work and workplace activity limitations following total hip or knee replacement.

    PubMed

    Sankar, A; Davis, A M; Palaganas, M P; Beaton, D E; Badley, E M; Gignac, M A

    2013-10-01

    Total hip (THR) and knee (TKR) replacements increasingly are performed on younger people making return to work a salient outcome. This research evaluates characteristics of individuals with early and later return to work following THR and TKR. Additionally, at work limitations pre-surgery and upon returning to work, and factors associated with work limitations were evaluated. 190 THR and 170 TKR of a total 931 cohort participants were eligible (i.e., working or on short-term disability pre-surgery). They completed questionnaires pre-surgery and 1, 3, 6 and 12 months post-surgery that included demographics, type of occupation, and the Workplace Activity Limitations Scale (WALS). 166 (87%) and 144 (85%) returned to work by 12 months following THR and TKR, respectively. Early (1 month) return to work was associated with, male gender, university education, working in business, finance or administration, and low physical demand work. People with THR returned to work earlier than those with TKR. For both groups, less pain and every day functional limitations were associated with less workplace activity limitations at the time return to work. The majority of individuals working prior to surgery return to work following hip or knee replacement for osteoarthritis (OA) and experience fewer limitations at work than pre-surgery. The changing workforce dynamics and trends toward surgery at younger ages mean that these are important outcomes for clinicians to assess. Additionally, this is important information for employers in understanding continued participation in employment for people with OA. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  7. Patient-specific instruments: advantages and pitfalls

    PubMed Central

    Hafez, Mahmoud A.; Moholkar, Kirti

    2017-01-01

    Patient-specific instruments (PSI) aim to improve the accuracy of total knee replacement (TKR) based on computer-assisted preoperative planning. In this work, the authors describe the advantages and pitfalls of PSI based on their clinical experience. The main conclusion of this work is that PSI has direct impact on the logistical and technical features of TKR with some advantages and pitfalls. PMID:29227785

  8. Combined Feature Based and Shape Based Visual Tracker for Robot Navigation

    NASA Technical Reports Server (NTRS)

    Deans, J.; Kunz, C.; Sargent, R.; Park, E.; Pedersen, L.

    2005-01-01

    We have developed a combined feature based and shape based visual tracking system designed to enable a planetary rover to visually track and servo to specific points chosen by a user with centimeter precision. The feature based tracker uses invariant feature detection and matching across a stereo pair, as well as matching pairs before and after robot movement in order to compute an incremental 6-DOF motion at each tracker update. This tracking method is subject to drift over time, which can be compensated by the shape based method. The shape based tracking method consists of 3D model registration, which recovers 6-DOF motion given sufficient shape and proper initialization. By integrating complementary algorithms, the combined tracker leverages the efficiency and robustness of feature based methods with the precision and accuracy of model registration. In this paper, we present the algorithms and their integration into a combined visual tracking system.

  9. Strategies utilized to transfer weight during knee flexion and extension with rotation for individuals with a total knee replacement.

    PubMed

    Ferris, Lauren A; Denney, Linda M; Maletsky, Lorin P

    2013-02-01

    Functional activities in daily life can require squatting and shifting body weight during transverse plane rotations. Stability of the knee can be challenging for people with a total knee replacement (TKR) due to reduced proprioception, nonconforming articular geometry, muscle strength, and soft tissue weakness. The objective of this study was to identify strategies utilized by individuals with TKR in double-stance transferring load during rotation and flexion. Twenty-three subjects were recruited for this study: 11 TKR subjects (age: 65 ± 6 years; BMI 27.4 ± 4.1) and 12 healthy subjects (age: 63 ± 7; BMI 24.6 ± 3.8). Each subject completed a novel crossover button push task where rotation, flexion, and extension of the knee were utilized. Each subject performed two crossover reaching tasks where the subject used the opposite hand to cross over their body and press a button next to either their shoulder (high) or knee (low), then switched hands and rotated to press the opposite button, either low or high. The two tasks related to the order they pressed the buttons while crossing over, either low-to-high (L2H) or high-to-low (H2L). Force platforms measured ground reaction forces under each foot, which were then converted to lead force ratios (LFRs) based on the total force. Knee flexion angles were also measured. No statistical differences were found in the LFRs during the H2L and L2H tasks for the different groups, although differences in the variation of the loading within subjects were noted. A significant difference was found between healthy and unaffected knee angles and a strong trend between healthy and affected subject's knee angles in both H2L and L2H tasks. Large variations in the LFR at mid-task in the TKR subjects suggested possible difficulties in maintaining positional stability during these tasks. The TKR subjects maintained more of an extended knee, which is a consistent quadriceps avoidance strategy seen by other researchers in different tasks. These outcomes suggest that individuals with a TKR utilize strategies, such as keeping an extended knee, to achieve rotary tasks during knee flexion and extension. Repeated compensatory movements could result in forces that may cause difficulty over time in the hip joints or low back. Early identification of these strategies could improve TKR success and the return to activities of daily living that involve flexion and rotation.

  10. Socio-economic position has no effect on improvement in health-related quality of life and patient satisfaction in total hip and knee replacement: a cohort study.

    PubMed

    Keurentjes, J Christiaan; Blane, David; Bartley, Melanie; Keurentjes, Johan J B; Fiocco, Marta; Nelissen, Rob G

    2013-01-01

    Considerable evidence suggests that patients with more advantaged Socio-Economic Positions undergo Total Hip and Knee Replacement (THR/TKR) more often, despite having a lower need. We questioned whether more disadvantaged Socio-Economic Position is associated with an lower improvement in Health-Related Quality of Life (HRQoL) and a lower patient satisfaction after THR/TKR. Patients who underwent primary THR/TKR in one academic and three community hospitals between 2005 and 2009, were eligible for inclusion. The highest completed levels of schooling were aggregated to index social class. We compared the improvement in HRQoL and postoperative satisfaction with surgery (measured using the Short-Form 36 (SF36) and an 11-point numeric rating scale of satisfaction) between the aggregated groups of highest completed levels of schooling, using linear mixed model analysis, with center as a random effect and potential confounders (i.e. age, gender, Body Mass Index and Charnley's comorbidity classification) as fixed effects. 586 THR patients and 400 TKR patients (40% of all eligible patients) agreed to participate and completed all questionnaires sufficiently. We found no differences in HRQoL improvement in any dimension of the SF36 in THR patients. Patients with a higher completed level of schooling had a larger improvement in role-physical (9.38 points, 95%-CI:0.34-18.4), a larger improvement in general health (3.67 points, 95%-CI:0.56-6.79) and a smaller improvement in mental health (3.60 points, 95%-CI:0.82-6.38) after TKR. Postoperative patient satisfaction did not differ between different highest completed level of schooling groups. Completed level of schooling has no effect on the improvement in HRQoL and patient satisfaction in a Dutch THR population and a small effect in a similar TKR population. Undertreatment of patients with more disadvantaged Socio-Economic Position cannot be justified, given the similar improvement in HRQoL and postoperative level of satisfaction with surgery between the social groups examined.

  11. Patterns of pharmacotherapy and health care utilization and costs prior to total hip or total knee replacement in patients with osteoarthritis.

    PubMed

    Berger, Ariel; Bozic, Kevin; Stacey, Brett; Edelsberg, John; Sadosky, Alesia; Oster, Gerry

    2011-08-01

    To examine patterns of pharmacotherapy and health care utilization and costs prior to total knee replacement (TKR) or total hip replacement (THR) in patients with osteoarthritis (OA). Using a large US health insurance claims database, we identified all patients with OA who were ages ≥40 years and had undergone TKR or THR between January 1, 2006 and December 31, 2007. Patients with <2 years of complete data prior to TKR or THR were excluded, as were those with evidence of other conditions for which TKR or THR may be performed (e.g., rheumatoid arthritis). We then examined patterns of health care utilization and costs over the 2-year period preceding surgery. A total of 16,527 patients met all study entry criteria. Their mean ± SD age was 56.6 ± 6.1 years, and 56% of them were women. In the 2 years preceding surgery, 55% of patients received prescription nonsteroidal antiinflammatory drugs, 58% received opioids, and 50% received injections of corticosteroids. The numbers of patients receiving these drugs increased steadily during the presurgery period. The mean ± SD total health care costs in the 2 years preceding surgery were $19,466 ± 29,869, of which outpatient care, inpatient care, and pharmacotherapy represented 45%, 20%, and 20%, respectively. Costs increased from $2,094 in the eighth calendar quarter prior to surgery to $3,100 in the final quarter. Patients with OA who undergo THR or TKR have relatively high levels of use of pain-related pharmacotherapy and high total health care costs in the 2-year period preceding surgery. Levels of utilization and cost increase as the date of surgery approaches. Copyright © 2011 by the American College of Rheumatology.

  12. Late Streptococcus bovis infection of total knee replacement complicated by infective endocarditis and associated with colonic ulcers

    PubMed Central

    Nagy, Mathias Thomas; Hla, Sann Minn; Keys, Graham Watson

    2013-01-01

    Streptococcus bovis is rare cause of late infections after total knee replacement (TKR). This report presents a case of confirmed late septic arthritis following TKR caused by S bovis that was further complicated with infective endocarditis resulting in aortic valve insufficiency in an immunecompetent patient. As an association between S bovis and gastrointestinal malignancies is suggested, a workup for such malignancies was performed that revealed non-malignant ulcers in patient's ascending colon. The patient is currently recovering from his aortic valve replacement surgery and is scheduled to have annual colonoscopies. His knee joint has improved; however, he developed constant pain because of underlying chronic infection in the affected joint and has difficulties mobilising. Therefore, a revision TKR is considered but postponed until he fully recovers from his heart valve surgery. PMID:23744853

  13. Dual mode scanner-tracker

    NASA Astrophysics Data System (ADS)

    Mongeon, R. J.

    1984-11-01

    The beam of a laser radar is moved over the field of view by means of a pair of scanner/trackers arranged in cascade along the laser beam. One of the scanner/trackers operates at high speed, with high resolution and a wide field and is located in the demagnified portion of the laser beam. The two scanner/trackers complement each other to achieve high speed, high resolution scanning as well as tracking of moving targets. A beam steering telescope for an airborne laser radar which incorporates the novel dual mode scanner/tracker is also shown. The other scanner/tracker operates at low speed with low resolution and a wide field and is located in the magnified portion of the laser beam.

  14. End-stage coxarthrosis and gonarthrosis. Aetiology, clinical patterns and radiological features of idiopathic osteoarthritis.

    PubMed

    Chitnavis, J; Sinsheimer, J S; Suchard, M A; Clipsham, K; Carr, A J

    2000-06-01

    To determine and compare the aetiological background, clinical patterns and radiological features of idiopathic osteoarthritis (OA) of the hip and the knee warranting arthroplasty. A total of 402 Caucasians consecutively undergoing total hip replacement (THR) or total knee replacement (TKR) for idiopathic OA at a major centre was surveyed. Previous joint injury was more common in the TKR group (P < 0.0001). However, both groups manifested a mixed occupational background, body mass indices similar to the general population and a predominance of females (F:M = 1.3-1.4:1). The TKR group had a significantly younger age of symptom onset (56 yr) than the THR group (61 yr) but both groups had a tendency to bilateral arthroplasty (33%), nodal involvement (54-59%), a significant excess of right-sided replacements (1.8:1, THR; 2.2:1, TKR) and similar levels of pre-operative pain and disability. Up to 40% of hips manifested acetabular dysplasia and 10% possible previous slipped upper femoral epiphyses. Eighty-five per cent with end-stage coxarthrosis or gonarthrosis had an identical pattern of radiographic disease contralaterally. Our data suggest the importance of a constitutional tendency to idiopathic, end-stage OA, a disorder traditionally associated with environmental factors leading to 'wear and tear'.

  15. Wear Scar Similarities between Retrieved and Simulator-Tested Polyethylene TKR Components: An Artificial Neural Network Approach

    PubMed Central

    2016-01-01

    The aim of this study was to determine how representative wear scars of simulator-tested polyethylene (PE) inserts compare with retrieved PE inserts from total knee replacement (TKR). By means of a nonparametric self-organizing feature map (SOFM), wear scar images of 21 postmortem- and 54 revision-retrieved components were compared with six simulator-tested components that were tested either in displacement or in load control according to ISO protocols. The SOFM network was then trained with the wear scar images of postmortem-retrieved components since those are considered well-functioning at the time of retrieval. Based on this training process, eleven clusters were established, suggesting considerable variability among wear scars despite an uncomplicated loading history inside their hosts. The remaining components (revision-retrieved and simulator-tested) were then assigned to these established clusters. Six out of five simulator components were clustered together, suggesting that the network was able to identify similarities in loading history. However, the simulator-tested components ended up in a cluster at the fringe of the map containing only 10.8% of retrieved components. This may suggest that current ISO testing protocols were not fully representative of this TKR population, and protocols that better resemble patients' gait after TKR containing activities other than walking may be warranted. PMID:27597955

  16. Timing of Re-Transfusion Drain Removal Following Total Knee Replacement

    PubMed Central

    Leeman, MF; Costa, ML; Costello, E; Edwards, D

    2006-01-01

    INTRODUCTION The use of postoperative drains following total knee replacement (TKR) has recently been modified by the use of re-transfusion drains. The aim of our study was to investigate the optimal time for removal of re-transfusion drains following TKR. PATIENTS AND METHODS The medical records of 66 patients who had a TKR performed between October 2003 and October 2004 were reviewed; blood drained before 6 h and the total volume of blood drained was recorded. RESULTS A total of 56 patients had complete records of postoperative drainage. The mean volume of blood collected in the drain in the first 6 h was 442 ml. The mean total volume of blood in the drain was 595 ml. Therefore, of the blood drained, 78% was available for transfusion. CONCLUSION Re-transfusion drains should be removed after 6 h, when no further re-transfusion is permissible. PMID:16551400

  17. Agile Mcal, the Mini-Calorimeter

    NASA Astrophysics Data System (ADS)

    Bastia, Paolo; Poulsen, Jens Michael; Monzani, Franco; Radaelli, Paolo; Marchesi, Paolo; Labanti, Claudio; Marisaldi, Martino; Fuschino, Fabio; Bulgarelli, Andrea

    2006-04-01

    AGILE is a scientific mission dedicated to gamma-ray astrophysics in space, and the mini-calorimeter MCAL is one of four detector systems on the satellite. The MCAL instrument is sensitive in the energy range: 300 keV - 100 MeV. It has two main functions: one autonomous mode for detection of impulsive cosmic events and the other as “a slave” supporting the energy measurements of the pair-conversion tracker. The AGILE Small Mission is funded by the Italian Space Agency (ASI), and the INAF-IASF section at Bologna has the scientific responsibility for MCAL. LABEN develops the MCAL instrument with its detectors and electronics. This paper gives an overview of the detectors on AGILE, and then it gives details on the design of MCAL, and finally we report on the tests at instrument level.

  18. Local anaesthetic infiltration for peri-operative pain control in total hip and knee replacement: systematic review and meta-analyses of short- and long-term effectiveness.

    PubMed

    Marques, Elsa M R; Jones, Hayley E; Elvers, Karen T; Pyke, Mark; Blom, Ashley W; Beswick, Andrew D

    2014-07-05

    Surgical pain is managed with multi-modal anaesthesia in total hip replacement (THR) and total knee replacement (TKR). It is unclear whether including local anaesthetic infiltration before wound closure provides additional pain control. We performed a systematic review of randomised controlled trials of local anaesthetic infiltration in patients receiving THR or TKR. We searched MEDLINE, Embase and Cochrane CENTRAL to December 2012. Two reviewers screened abstracts, extracted data, and contacted authors for unpublished outcomes and data. Outcomes collected were post-operative pain at rest and during activity after 24 and 48 hours, opioid requirement, mobilisation, hospital stay and complications. When feasible, we estimated pooled treatment effects using random effects meta-analyses. In 13 studies including 909 patients undergoing THR, patients receiving local anaesthetic infiltration experienced a greater reduction in pain at 24 hours at rest by standardised mean difference (SMD) -0.61 (95% CI -1.05, -0.16; p = 0.008) and by SMD -0.43 (95% CI -0.78 -0.09; p = 0.014) at 48 hours during activity.In TKR, diverse multi-modal regimens were reported. In 23 studies including 1439 patients undergoing TKR, local anaesthetic infiltration reduced pain on average by SMD -0.40 (95% CI -0.58, -0.22; p < 0.001) at 24 hours at rest and by SMD -0.27 (95% CI -0.50, -0.05; p = 0.018) at 48 hours during activity, compared with patients receiving no infiltration or placebo. There was evidence of a larger reduction in studies delivering additional local anaesthetic after wound closure. There was no evidence of pain control additional to that provided by femoral nerve block.Patients receiving local anaesthetic infiltration spent on average an estimated 0.83 (95% CI 1.54, 0.12; p = 0.022) and 0.87 (95% CI 1.62, 0.11; p = 0.025) fewer days in hospital after THR and TKR respectively, had reduced opioid consumption, earlier mobilisation, and lower incidence of vomiting.Few studies reported long-term outcomes. Local anaesthetic infiltration is effective in reducing short-term pain and hospital stay in patients receiving THR and TKR. Studies should assess whether local anaesthetic infiltration can prevent long-term pain. Enhanced pain control with additional analgesia through a catheter should be weighed against a possible infection risk.

  19. jTracker and Monte Carlo Comparison

    NASA Astrophysics Data System (ADS)

    Selensky, Lauren; SeaQuest/E906 Collaboration

    2015-10-01

    SeaQuest is designed to observe the characteristics and behavior of `sea-quarks' in a proton by reconstructing them from the subatomic particles produced in a collision. The 120 GeV beam from the main injector collides with a fixed target and then passes through a series of detectors which records information about the particles produced in the collision. However, this data becomes meaningful only after it has been processed, stored, analyzed, and interpreted. Several programs are involved in this process. jTracker (sqerp) reads wire or hodoscope hits and reconstructs the tracks of potential dimuon pairs from a run, and Geant4 Monte Carlo simulates dimuon production and background noise from the beam. During track reconstruction, an event must meet the criteria set by the tracker to be considered a viable dimuon pair; this ensures that relevant data is retained. As a check, a comparison between a new version of jTracker and Monte Carlo was made in order to see how accurately jTracker could reconstruct the events created by Monte Carlo. In this presentation, the results of the inquest and their potential effects on the programming will be shown. This work is supported by U.S. DOE MENP Grant DE-FG02-03ER41243.

  20. A cost-utility analysis of dabigatran, enoxaparin, and usual care for venous thromboprophylaxis after hip or knee replacement surgery in Thailand.

    PubMed

    Kotirum, Surachai; Chongmelaxme, Bunchai; Chaiyakunapruk, Nathorn

    2017-02-01

    To analyze the cost-utility of oral dabigatran etexilate, enoxaparin sodium injection, and no intervention for venous thromboembolism (VTE) prophylaxis after total hip or knee replacement (THR/TKR) surgery among Thai patients. A cost-utility analysis using a decision tree model was conducted using societal and healthcare payers' perspectives to simulate relevant costs and health outcomes covering a 3-month time horizon. Costs were adjusted to year 2014. The willingness-to-pay threshold of THB 160,000 (USD 4926) was used. One-way sensitivity and probabilistic sensitivity analyses using a Monte Carlo simulation were performed. Compared with no VTE prophylaxis, dabigatran and enoxaparin after THR and TKR surgery incurred higher costs and increased quality adjusted life years (QALYs). However, their incremental cost-effectiveness ratios were high above the willingness to pay. Compared with enoxaparin, dabigatran for THR/TKR lowered VTE complications but increased bleeding cases; dabigatran was cost-saving by reducing the costs [by THB 3809.96 (USD 117.30) for THR] and producing more QALYs gained (by 0.00013 for THR). Dabigatran (vs. enoxaparin) had a 98 % likelihood of being cost effective. Dabigatran is cost-saving compared to enoxaparin for VTE prophylaxis after THR or TKR under the Thai context. However, both medications are not cost-effective compared to no thromboprophylaxis.

  1. Current concepts and future perspectives in computer-assisted navigated total knee replacement.

    PubMed

    Matsumoto, Tomoyuki; Nakano, Naoki; Lawrence, John E; Khanduja, Vikas

    2018-05-12

    Total knee replacements (TKR) aim to restore stability of the tibiofemoral and patella-femoral joints and provide relief of pain and improved quality of life for the patient. In recent years, computer-assisted navigation systems have been developed with the aim of reducing human error in joint alignment and improving patient outcomes. We examined the current body of evidence surrounding the use of navigation systems and discussed their current and future role in TKR. The current body of evidence shows that the use of computer navigation systems for TKR significantly reduces outliers in the mechanical axis and coronal prosthetic position. Also, navigation systems offer an objective assessment of soft tissue balancing that had previously not been available. Although these benefits represent a technical superiority to conventional TKR techniques, there is limited evidence to show long-term clinical benefit with the use of navigation systems, with only a small number of studies showing improvement in outcome scores at short-term follow-up. Because of the increased costs and operative time associated with their use as well as the emergence of more affordable and patient-specific technologies, it is unlikely for navigation systems to become more widely used in the near future. Whilst this technology helps surgeons to achieve improved component positioning, it is important to consider the clinical and functional implications, as well as the added costs and potential learning curve associated with adopting new technology.

  2. A real time biofeedback using Kinect and Wii to improve gait for post-total knee replacement rehabilitation: a case study report.

    PubMed

    Levinger, Pazit; Zeina, Daniel; Teshome, Assefa K; Skinner, Elizabeth; Begg, Rezaul; Abbott, John Haxby

    2016-01-01

    This study aimed to develop a low-cost real-time biofeedback system to assist with rehabilitation for patients following total knee replacement (TKR) and to assess its feasibility of use in a post-TKR patient case study design with a comparison group. The biofeedback system consisted of Microsoft Kinect(TM) and Nintendo Wii balance board with a dedicated software. A six-week inpatient rehabilitation program was augmented by biofeedback and tested in a single patient following TKR. Three patients underwent a six weeks standard rehabilitation with no biofeedback and served as a control group. Gait, function and pain were assessed and compared before and after the rehabilitation. The biofeedback software incorporated real time visual feedback to correct limb alignment, movement pattern and weight distribution. Improvements in pain, function and quality of life were observed in both groups. The strong improvement in the knee moment pattern demonstrated in the case study indicates feasibility of the biofeedback-augmented intervention. This novel biofeedback software has used simple commercially accessible equipment that can be feasibly incorporated to augment a post-TKR rehabilitation program. Our preliminary results indicate the potential of this biofeedback-assisted rehabilitation to improve knee function during gait. Research is required to test this hypothesis. Implications for Rehabilitation The real-time biofeedback system developed integrated custom-made software and simple low-cost commercially accessible equipment such as Kinect and Wii board to provide augmented information during rehabilitation following TKR. The software incorporated key rehabilitation principles and visual feedback to correct alignment of the lower legs, pelvic and trunk as well as providing feedback on limbs weight distribution. The case study patient demonstrated greater improvement in their knee function where a more normal biphasic knee moment was achieved following the six-week biofeedback intervention.

  3. Self-Reported Knee Instability Before and After Total Knee Replacement Surgery.

    PubMed

    Fleeton, Genevieve; Harmer, Alison R; Nairn, Lillias; Crosbie, Jack; March, Lyn; Crawford, Ross; van der Esch, Martin; Fransen, Marlene

    2016-04-01

    To determine the prevalence and burden of pain and activity limitations associated with retaining presurgery self-reported knee instability 6 months after total knee replacement (TKR) surgery and to identify early potentially modifiable risk factors for retaining knee instability in the operated knee after TKR surgery. A secondary analysis was performed using measures obtained from 390 participants undergoing primary unilateral TKR and participating in a randomized clinical trial. Self-reported knee instability was measured using 2 items from the Activities of Daily Living Scale of the Knee Outcome Survey. Outcome measures were knee pain (range 0-20) and physical function (range 0-68) on the Western Ontario and McMaster Universities Arthritis Index (WOMAC), stair-climb power, 50-foot walk time, knee range of motion, and isometric knee flexion and extension strength. In this study, 72% of participants reported knee instability just prior to surgery, with 32% retaining instability in the operated knee 6 months after surgery. Participants retaining operated knee instability had significantly more knee pain and activity limitations 6 months after surgery, with mean ± SD WOMAC scores of 4.8 ± 3.7 and 17.5 ± 11.1, respectively, compared to participants without knee instability, with 2.9 ± 3.1 and 9.8 ± 9.2. The multivariable predictor model for retained knee instability included a high comorbidity score (>6), low stair-climb power (<150 watts), more pain in the operated knee (>7 of 20), and younger age (<60 years). Self-reported knee instability is highly prevalent before and after TKR surgery and is associated with a considerable burden of pain and activity limitation in the operated knee. Increasing lower extremity muscle power may reduce the risk of retaining knee instability after TKR surgery. © 2016, American College of Rheumatology.

  4. How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study.

    PubMed

    Pourzal, Robin; Knowlton, Christopher B; Hall, Deborah J; Laurent, Michel P; Urban, Robert M; Wimmer, Markus A

    2016-08-01

    The longevity of total hip (THR) and knee replacements (TKR) that used historical bearing materials of gamma-in-air sterilized UHMWPE was affected more by osteolysis in THRs than in TKRs, although osteolysis remains a concern in TKRs. Therefore, the study of polyethylene wear is still of interest for the knee, particularly because few studies have investigated volumetric material loss in tibial knee inserts. For this study, a unique collection of autopsy-retrieved TKR and THR components that were well-functioning at the time of retrieval was used to compare volumetric wear differences between hip and knee polyethylene components made from identical material. The following questions were addressed: (1) How much did the hip liners wear and what wear patterns did they exhibit? (2) How much did the knee inserts wear and what wear patterns did they exhibit? (3) What is the ratio between TKR and THR wear after controlling for implantation time and patient age? We compared 23 THR components (Harris-Galante [HG] and HG II) and 20 TKR components (Miller-Galante [MG II]) that were retrieved postmortem. The components were made from the same polyethylene formulation and with similar manufacturing and sterilization (gamma-in-air) processes. Twenty-one patients (12 males, nine females) had THRs and 16 (four males, 12 females) had TKRs. Patients who had TKRs had an older (p = 0.001) average age than patients who had THRs (age, 75 years; SD, 10, versus 66 years; SD, 12, respectively). Only well-functioning components were included in this study. Therefore, implants retrieved postmortem from physically active patients and implanted for at least 2 years were considered. In addition, only normally wearing TKR components were considered, ie, those with fatigue wear (delamination) were excluded. The wear volume of each component was measured using metrology. For the tibial inserts an autonomous mathematic reconstruction method was used for quantification. The acetabular liners of the THR group had a wear rate of 38 mm(3) per year (95% CI, 29-47 mm(3)/year). Excluding patients with low-activity, the wear rate was 47 mm(3) per year (95% CI, 37-56 mm(3)/year). The wear rate of normally wearing tibial inserts was 17 mm(3) per year (95% CI, -6 to 40 mm(3)/year). After controlling for the relevant confounding variable of age, we found a TKR/THR wear rate ratio of 0.5 (95% CI, 0.29-0.77) at 70 years of age with a slightly increasing difference with increasing age. Excluding delamination, TKRs exhibited lower articular wear rates than THRs for historical polyethylene in these two unique cohorts of postmortem retrievals. The lower TKR wear rate is in line with the lower incidence of osteolysis in TKRs compared with THRs.

  5. Clinical and cost outcomes of venous thromboembolism in Medicare patients undergoing total hip replacement or total knee replacement surgery.

    PubMed

    Baser, Onur; Supina, Dylan; Sengupta, Nishan; Wang, Li; Kwong, Louis

    2011-02-01

    Venous thromboembolism (VTE) occurs most often during hospitalization for major surgery or trauma but may also occur up to several months after surgery. Since the potential for VTE exists in a range of clinical settings, an assessment of its impact on overall outcomes and costs to the patient and to the healthcare system is warranted. To evaluate the effects of VTE (deep vein thrombosis, pulmonary embolism, or both) occurring within the first 30 days of hospital discharge for total hip replacement (THR) or total knee replacement (TKR) surgery on inpatient costs, mortality, rehospitalization, and major bleeding within 1 year after initial hospitalization for THR or TKR surgery. The Medicare Provider Analysis and Review (MEDPAR) file for calendar years 2005-2007 provided hospital discharge abstracts for the fee-for-service, acute-care hospitalizations of all Medicare recipients. All patients included in the analysis underwent THR (n = 51,108) or TKR (n = 115,627). VTE events were diagnosed within the first 30 days and within 1 year post discharge. Propensity score matching was used to control for differences in baseline characteristics in patients with and without VTE events. Total cost was measured as Medicare cost plus beneficiary out-of-pocket cost. VTE occurred in 0.74% of patients undergoing THR. For patients with VTE versus no VTE, mortality was higher (2.9% vs 0.4%, P < 0.001) and rehospitalization within 1 year was more frequent (51.9% vs 22.4%, P < 0.001), as were complications such as bleeding (11.2% vs 2.7%, P < 0.001). Risk-adjusted Medicare cost and total healthcare cost, including beneficiary cost share in 1 year, were significantly higher for VTE patients versus patients with no VTE ($18,929 vs $3763, P < 0.001). VTE occurred in 0.70% of patients undergoing TKR. For patients with VTE versus no VTE, mortality was higher (2.5% vs 0.15%, P < 0.001), and rehospitalization within 1 year was more frequent (48.7% vs 20.7%, P < 0.001), as were complications such as bleeding (13.7% vs 2.1%, P < 0.001). For TKR surgery, risk-adjusted total healthcare cost, including beneficiary cost share in 1 year, was significantly different for VTE versus no VTE ($17,996 vs $4358, P < 0.001). Study limitations include a reliance on ICD-9-CM codes, which could be inaccurate, and the inability (1) to control for unmeasured confounders, such as surgeons' skills; (2) to include outpatient medical care costs; and (3) to ensure that all patients were enrolled continuously throughout the study period. VTE after THR or TKR is associated with higher mortality, rehospitalization, and bleeding within 1 year, compared with no VTE. Risk-adjusted total, Medicare, and beneficiary healthcare costs were significantly higher for both THR and TKR patients with VTE (P < 0.001).

  6. Tensor-product kernel-based representation encoding joint MRI view similarity.

    PubMed

    Alvarez-Meza, A; Cardenas-Pena, D; Castro-Ospina, A E; Alvarez, M; Castellanos-Dominguez, G

    2014-01-01

    To support 3D magnetic resonance image (MRI) analysis, a marginal image similarity (MIS) matrix holding MR inter-slice relationship along every axis view (Axial, Coronal, and Sagittal) can be estimated. However, mutual inference from MIS view information poses a difficult task since relationships between axes are nonlinear. To overcome this issue, we introduce a Tensor-Product Kernel-based Representation (TKR) that allows encoding brain structure patterns due to patient differences, gathering all MIS matrices into a single joint image similarity framework. The TKR training strategy is carried out into a low dimensional projected space to get less influence of voxel-derived noise. Obtained results for classifying the considered patient categories (gender and age) on real MRI database shows that the proposed TKR training approach outperforms the conventional voxel-wise sum of squared differences. The proposed approach may be useful to support MRI clustering and similarity inference tasks, which are required on template-based image segmentation and atlas construction.

  7. Perioperative blood management strategies for patients undergoing total knee replacement: Where do we stand now?

    PubMed Central

    Themistoklis, Tzatzairis; Theodosia, Vogiatzaki; Konstantinos, Kazakos; Georgios, Drosos I

    2017-01-01

    Total knee replacement (TKR) is one of the most common surgeries over the last decade. Patients undergoing TKR are at high risk for postoperative anemia and furthermore for allogeneic blood transfusions (ABT). Complications associated with ABT including chills, rigor, fever, dyspnea, light-headedness should be early recognized in order to lead to a better prognosis. Therefore, perioperative blood management program should be adopted with main aim to reduce the risk of blood transfusion while maximizing hemoglobin simultaneously. Many blood conservation strategies have been attempted including preoperative autologous blood donation, acute normovolemic haemodilution, autologous blood transfusion, intraoperative cell saver, drain clamping, pneumatic tourniquet application, and the use of tranexamic acid. For practical and clinical reasons we will try to classify these strategies in three main stages/pillars: Pre-operative optimization, intra-operative and post-operative protocols. The aim of this work is review the strategies currently in use and reports our experience regarding the perioperative blood management strategies in TKR. PMID:28660135

  8. Computer-assisted revision total knee replacement.

    PubMed

    Sikorski, J M

    2004-05-01

    A technique for performing allograft-augmented revision total knee replacement (TKR) using computer assistance is described, on the basis of the results in 14 patients. Bone deficits were made up with impaction grafting. Femoral grafting was made possible by the construction of a retaining wall or dam which allowed pressurisation and retention of the graft. Tibial grafting used a mixture of corticocancellous and morsellised allograft. The position of the implants was monitored by the computer system and adjusted while the cement was setting. The outcome was determined using a six-parameter, quantitative technique (the Perth CT protocol) which measured the alignment of the prosthesis and provided an objective score. The final outcomes were not perfect with errors being made in femoral rotation and in producing a mismatch between the femoral and tibial components. In spite of the shortcomings the alignments were comparable in accuracy with those after primary TKR. Computer assistance shows considerable promise in producing accurate alignment in revision TKR with bone deficits.

  9. Development of a Beam Trajectory Monitoring System Using e+/e- Pair Production Events

    NASA Astrophysics Data System (ADS)

    Kimura, Shota; Emoto, Yusaku; Fujihara, Kento; Ito, Hiroshi; Kawai, Hideyuki; Kobayashi, Atsushi; Mizuno, Takahiro

    2018-01-01

    In particle therapy, it is important to monitor the Bragg-peak position. It was simulated by GEANT4 Monte Carlo Simulation Code that the distribution of secondary generated gamma rays on the carbon beam therapy and the proton beam therapy. This simulation shows that gamma rays whose energy is 10 MeV or more are intensively generated at the Bragg-peak position. We are developing the system to monitor the Bragg-peak position which can measure pair production events occurred in the detector by gamma rays from irradiation points. The momentum direction of the gamma ray can be determined by measuring passing points and energy of e+ and e- generated by pair production. This system has 5 parts. The first is the conversion part. This part consists of several layers. Each layer is composed of a La-GPS ((Gd0.75La0.24Ce0.01)2Si2O7) scintillator plate and wavelength-shifting fibre (WLSF) sheets. The scintillator plate is sandwiched between sheets, where the directions of the sheets are in orthogonally x and y directions. In this part, gamma rays are converted to e+ e- pairs and the position where the conversion occured is determined. The second is the tracking part. This part consists of 2 layers of scintillating fibre tracker. Each layer has 6 scintillating fibre sheets for x, x', u, u', v, and v'. The third is the energy measurement part. It measures the energy of e+ and e- by scintillator array and Silicon Photomultipliers. The fourth is the veto counter for bremsstrahlung gamma rays from e+ and e-. The fifth is the beam monitor. By experiment, the number of photoelectrons of La-GPS with a WLSF (B-3(300)MJ, Kuraray) sheet and scintillating fibre (SCSF-78, Kuraray) when charged particle passed was measured as 9.7 and 7.6 respectively.

  10. The development and validation of a multivariable model to predict whether patients referred for total knee replacement are suitable surgical candidates at the time of initial consultation.

    PubMed

    Churchill, Laura; Malian, Samuel J; Chesworth, Bert M; Bryant, Dianne; MacDonald, Steven J; Marsh, Jacquelyn D; Giffin, J Robert

    2016-12-01

    In previous studies, 50%-70% of patients referred to orthopedic surgeons for total knee replacement (TKR) were not surgical candidates at the time of initial assessment. The purpose of our study was to identify and cross-validate patient self-reported predictors of suitability for TKR and to determine the clinical utility of a predictive model to guide the timing and appropriateness of referral to a surgeon. We assessed pre-consultation patient data as well as the surgeon's findings and post-consultation recommendations. We used multivariate logistic regression to detect self-reported items that could identify suitable surgical candidates. Patients' willingness to undergo surgery, higher rating of pain, greater physical function, previous intra-articular injections and patient age were the factors predictive of patients being offered and electing to undergo TKR. The application of the model developed in our study would effectively reduce the proportion of nonsurgical referrals by 25%, while identifying the vast majority of surgical candidates (> 90%). Using patient-reported information, we can correctly predict the outcome of specialist consultation for TKR in 70% of cases. To reduce long waits for first consultation with a surgeon, it may be possible to use these items to educate and guide referring clinicians and patients to understand when specialist consultation is the next step in managing the patient with severe osteoarthritis of the knee.

  11. The development and validation of a multivariable model to predict whether patients referred for total knee replacement are suitable surgical candidates at the time of initial consultation

    PubMed Central

    Churchill, Laura; Malian, Samuel J.; Chesworth, Bert M.; Bryant, Dianne; MacDonald, Steven J.; Marsh, Jacquelyn D.; Giffin, J. Robert

    2016-01-01

    Background In previous studies, 50%–70% of patients referred to orthopedic surgeons for total knee replacement (TKR) were not surgical candidates at the time of initial assessment. The purpose of our study was to identify and cross-validate patient self-reported predictors of suitability for TKR and to determine the clinical utility of a predictive model to guide the timing and appropriateness of referral to a surgeon. Methods We assessed pre-consultation patient data as well as the surgeon’s findings and post-consultation recommendations. We used multivariate logistic regression to detect self-reported items that could identify suitable surgical candidates. Results Patients’ willingness to undergo surgery, higher rating of pain, greater physical function, previous intra-articular injections and patient age were the factors predictive of patients being offered and electing to undergo TKR. Conclusion The application of the model developed in our study would effectively reduce the proportion of nonsurgical referrals by 25%, while identifying the vast majority of surgical candidates (> 90%). Using patient-reported information, we can correctly predict the outcome of specialist consultation for TKR in 70% of cases. To reduce long waits for first consultation with a surgeon, it may be possible to use these items to educate and guide referring clinicians and patients to understand when specialist consultation is the next step in managing the patient with severe osteoarthritis of the knee. PMID:28234616

  12. Development of friction and wear full-scale testing for TKR prostheses with reliable low cost apparatus

    NASA Astrophysics Data System (ADS)

    Suwandi, Agri; Soemardi, Tresna P.; Kiswanto, Gandjar; Kusumaningsih, Widjajalaksmi; I. Gusti Agung I. G., W.

    2018-02-01

    Prostheses products must undergo simulation and physical testing, before clinical testing. Finite element method is a preliminary simulation for in vivo test. The method visualizes the magnitude of the compressive force and the critical location of the Total Knee Replacement (TKR) prostheses design. In vitro testing is classified as physical testing for prostheses product. The test is conducted to evaluate the potential failure of the product and the characteristics of the prostheses TKR material. Friction and wear testing are part of the in vivo test. Motion of knee joints, which results in the phenomena of extension and deflection in the femoral and tibia insert, is represented by friction and wear testing. Friction and wear tests aim to obtain an approximate lifetime in normal and extreme load patterns as characterized by the shape of the friction surface area. The lifetime estimation requires friction and wear full-scale testing equipments for TKR prostheses products. These are necessary in obtaining initial data on potential product failures and characterizing of the material based on the ASTM F2724-08 standards. Based on the testing result and statistical analysis data, the average wear rate value per year is 2.19 × 10-3 mg/MC, with a 10 % safety limit of volume and 14,400 cycles times, for 15 hours moving nonstop then the prediction of wear life of the component tibia insert is ± 10 years.

  13. Local anaesthetic infiltration for peri-operative pain control in total hip and knee replacement: systematic review and meta-analyses of short- and long-term effectiveness

    PubMed Central

    2014-01-01

    Background Surgical pain is managed with multi-modal anaesthesia in total hip replacement (THR) and total knee replacement (TKR). It is unclear whether including local anaesthetic infiltration before wound closure provides additional pain control. Methods We performed a systematic review of randomised controlled trials of local anaesthetic infiltration in patients receiving THR or TKR. We searched MEDLINE, Embase and Cochrane CENTRAL to December 2012. Two reviewers screened abstracts, extracted data, and contacted authors for unpublished outcomes and data. Outcomes collected were post-operative pain at rest and during activity after 24 and 48 hours, opioid requirement, mobilisation, hospital stay and complications. When feasible, we estimated pooled treatment effects using random effects meta-analyses. Results In 13 studies including 909 patients undergoing THR, patients receiving local anaesthetic infiltration experienced a greater reduction in pain at 24 hours at rest by standardised mean difference (SMD) -0.61 (95% CI -1.05, -0.16; p = 0.008) and by SMD -0.43 (95% CI -0.78 -0.09; p = 0.014) at 48 hours during activity. In TKR, diverse multi-modal regimens were reported. In 23 studies including 1439 patients undergoing TKR, local anaesthetic infiltration reduced pain on average by SMD -0.40 (95% CI -0.58, -0.22; p < 0.001) at 24 hours at rest and by SMD -0.27 (95% CI -0.50, -0.05; p = 0.018) at 48 hours during activity, compared with patients receiving no infiltration or placebo. There was evidence of a larger reduction in studies delivering additional local anaesthetic after wound closure. There was no evidence of pain control additional to that provided by femoral nerve block. Patients receiving local anaesthetic infiltration spent on average an estimated 0.83 (95% CI 1.54, 0.12; p = 0.022) and 0.87 (95% CI 1.62, 0.11; p = 0.025) fewer days in hospital after THR and TKR respectively, had reduced opioid consumption, earlier mobilisation, and lower incidence of vomiting. Few studies reported long-term outcomes. Conclusions Local anaesthetic infiltration is effective in reducing short-term pain and hospital stay in patients receiving THR and TKR. Studies should assess whether local anaesthetic infiltration can prevent long-term pain. Enhanced pain control with additional analgesia through a catheter should be weighed against a possible infection risk. PMID:24996539

  14. Measurement of Thrombus Flux Using Transesophageal Echocardiography

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya, Hiroyuki

    2006-05-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the FSET to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed.

  15. The levels of the adipokines adipsin and leptin are associated with knee osteoarthritis progression as assessed by MRI and incidence of total knee replacement in symptomatic osteoarthritis patients: a post hoc analysis.

    PubMed

    Martel-Pelletier, Johanne; Raynauld, Jean-Pierre; Dorais, Marc; Abram, François; Pelletier, Jean-Pierre

    2016-04-01

    Limited studies have explored the association between adipokines and knee OA structural progression using quantitative MRI (qMRI), and very few have included total knee replacement (TKR) as a disease outcome. The objective of this study was to compare serum levels of five adipokines to cartilage volume loss (CVL) and investigate their predictive value for TKR. The according-to-protocol population (n = 138) of a knee OA trial was used. Serum levels of adipsin (complement factor D), leptin, adiponectin, resistin and serpin E1, and cartilage volume were determined at baseline and 24 months with specific ELISAs and qMRI, respectively. Study knee TKR incidence up to 4 years post-trial was also assessed. Greater baseline values of adipsin and leptin correlated with increased CVL in the global knee and medial femur (P ⩽ 0.032) and of adipsin in the lateral compartment and femur (P ⩽ 0.028). Adiponectin showed an inverse correlation in the medial compartment and femur (P ⩽ 0.027). Resistin and serpin E1 were not associated with CVL. Multivariate analyses revealed that patients in the highest tertile at baseline of adipsin presented a greater odds ratio of CVL in the lateral compartment and femur (⩾2.87; P ⩽ 0.011), and those in the highest tertile of leptin in the medial compartment (2.78; P = 0.038). Most clinically relevant, patients in the highest tertile of adipsin or leptin at baseline had significantly greater incidence of TKR (P = 0.027). Data demonstrate that both adipsin and leptin predict greater CVL over time in the lateral and medial compartment, respectively. Importantly, this study also demonstrates that higher baseline levels of adipsin or leptin are associated with higher incidence of TKR. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Intramedullary Arthrodesis of the Knee in the Treatment of Sepsis After TKR

    PubMed Central

    Bono, James V.; Figgie, Mark P.; Sculco, Thomas P.; Laskin, Richard S.; Windsor, Russell E.

    2007-01-01

    Infection is a devastating complication following total knee replacement (TKR). In the majority of cases, single- or two-stage revision has excellent results in eradicating infection and restoring function. Rarely, recurrent infection requires alternative treatments such as resection, amputation, or arthrodesis. A review of infections following TKR treated at two joint replacement centers identified 29 cases of resistant knee sepsis treated with a long intramedullary fusion nail. Clinical outcome and radiographs were reviewed at an average follow-up of 48 months (13–114). After the initial intramedullary arthrodesis union occurred in 24 of 29 patients (83%). The average time to fusion was 6 months (3–18 months). Failures included two cases of nail breakage, one of which subsequently achieved fusion following revision nailing, and three cases of recurrent infection requiring nail removal and permanent resection. At a minimum 2-year follow-up, 28% of the patients that achieved fusion complained of pain in the fused knee, 28% complained of ipsilateral hip pain, and two patients complained of contralateral knee pain. Four of the 25 fused patients (16%) remained nonambulatory after fusion, 17 required walking aids (68%) and only four ambulated unassisted. There was no association between age, number of previous procedures, the use of two-stage versus single stage technique, or infecting organism and failure of arthrodesis. Intramedullary arthrodesis is a viable treatment for refractory infection after TKR. Patients undergoing fusion should be informed of the potential for nonunion, recurrence of infection, pain in the ipsilateral extremity, and the long-term need for walking aids. PMID:18751775

  17. Intramedullary arthrodesis of the knee in the treatment of sepsis after TKR.

    PubMed

    Talmo, Carl T; Bono, James V; Figgie, Mark P; Sculco, Thomas P; Laskin, Richard S; Windsor, Russell E

    2007-02-01

    Infection is a devastating complication following total knee replacement (TKR). In the majority of cases, single- or two-stage revision has excellent results in eradicating infection and restoring function. Rarely, recurrent infection requires alternative treatments such as resection, amputation, or arthrodesis. A review of infections following TKR treated at two joint replacement centers identified 29 cases of resistant knee sepsis treated with a long intramedullary fusion nail. Clinical outcome and radiographs were reviewed at an average follow-up of 48 months (13-114). After the initial intramedullary arthrodesis union occurred in 24 of 29 patients (83%). The average time to fusion was 6 months (3-18 months). Failures included two cases of nail breakage, one of which subsequently achieved fusion following revision nailing, and three cases of recurrent infection requiring nail removal and permanent resection. At a minimum 2-year follow-up, 28% of the patients that achieved fusion complained of pain in the fused knee, 28% complained of ipsilateral hip pain, and two patients complained of contralateral knee pain. Four of the 25 fused patients (16%) remained nonambulatory after fusion, 17 required walking aids (68%) and only four ambulated unassisted. There was no association between age, number of previous procedures, the use of two-stage versus single stage technique, or infecting organism and failure of arthrodesis. Intramedullary arthrodesis is a viable treatment for refractory infection after TKR. Patients undergoing fusion should be informed of the potential for nonunion, recurrence of infection, pain in the ipsilateral extremity, and the long-term need for walking aids.

  18. Navigation-assisted versus conventional total knee replacement: no difference in patient-reported outcome measures (PROMs) at 1 and 2 years.

    PubMed

    Singisetti, Kiran; Muthumayandi, Karthikeyan; Abual-Rub, Zaid; Weir, David

    2015-11-01

    Navigation technique for total knee replacement has been shown to improve accuracy of prosthesis alignment in several studies. The purpose was to compare the patient-reported outcome measures in primary total knee replacement (TKR) using navigation versus conventional surgical technique at 1- and 2-year follow-up. A retrospective review of prospectively collected patient-reported outcome data for 351 consecutively performed primary TKR was included in the study. The study group (N = 113) included patients who had Triathlon TKR using articular surface mounted (ASM Stryker) navigation technique and control group (N = 238) included patients who had Triathlon TKR using conventional jig. In addition to the WOMAC (Western Ontario and McMaster University Osteoarthritis Index) and SF-36 (Medical Outcomes Trust Short Form-36), a short self-report questionnaire evaluating the level of satisfaction, quality of life and whether patients would undergo knee replacement again. WOMAC: no significant difference between the groups was noted in mean WOMAC pain, function and stiffness scores at 1- and 2-year follow-up. SF-36: no significant difference between the groups was seen except in the physical function component of score at 1 year (p = 0.019). Navigation group mean 56.78 (CI 51.06-62.5) versus conventional group mean 48.34 (44.68-52.01) but this difference was not observed at 2-year follow-up. The overall patient-reported outcome scores improved after total knee replacement but appear to be comparable in both groups at 1- and 2-year follow-up.

  19. Combinations of 148 navigation stars and the star tracker

    NASA Technical Reports Server (NTRS)

    Duncan, R.

    1980-01-01

    The angular separation of all star combinations for 148 nav star on the onboard software for space transportation system-3 flight and following missions is presented as well as the separation of each pair that satisfies the viewing constraints of using both star trackers simultaneously. Tables show (1) shuttle star catalog 1980 star position in M 1950 coordinates; (2) two star combination of 148 nav stars; and (3) summary of two star-combinations of the star tracker 5 deg filter. These 148 stars present 10,875 combinations. For the star tracker filters of plus or minus 5 deg, there are 875 combinations. Formalhaut (nav star 26) has the best number of combinations, which is 33.

  20. Tracking down quirks at the Large Hadron Collider

    NASA Astrophysics Data System (ADS)

    Knapen, Simon; Lou, Hou Keong; Papucci, Michele; Setford, Jack

    2017-12-01

    Nonhelical tracks are the smoking gun signature of charged and/or colored quirks, which are pairs of particles bound by a new, long-range confining force. We propose a method to efficiently search for these nonhelical tracks at the LHC, without the need to fit their trajectories. We show that the hits corresponding to quirky trajectories can be selected efficiently by searching for coplanar hits in the inner layers of the ATLAS and CMS trackers, even in the presence of on average 50 pile-up vertices. We further argue that backgrounds from photon conversions and unassociated pile-up hits can be removed almost entirely, while maintaining a signal reconstruction efficiency as high as ˜70 % . With the 300 fb-1 dataset, this implies a discovery potential for string tension between 100 eV and 30 keV, and colored (electroweak charged) quirks as heavy as 1600 (650) GeV may be discovered.

  1. Design of the forward straw tube tracker for the PANDA experiment

    NASA Astrophysics Data System (ADS)

    Smyrski, J.; Apostolou, A.; Biernat, J.; Czyżycki, W.; Filo, G.; Fioravanti, E.; Fiutowski, T.; Gianotti, P.; Idzik, M.; Korcyl, G.; Korcyl, K.; Lisowski, E.; Lisowski, F.; Płażek, J.; Przyborowski, D.; Przygoda, W.; Ritman, J.; Salabura, P.; Savrie, M.; Strzempek, P.; Swientek, K.; Wintz, P.; Wrońska, A.

    2017-06-01

    The design of the Forward Tracker for the Forward Spectrometer of the PANDA experiment is described. The tracker consists of 6 tracking stations, each comprising 4 planar double layers of straw tube detectors, and has a total material budget of only 2% X0. The straws are made self-supporting by a 1 bar over-pressure of the working gas mixture (Ar/CO2). This allows to use lightweight and compact rectangular support frames for the double layers and to split the frames into pairs of C-shaped half-frames for an easier installation on the beam line.

  2. Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis. A follow-up study of 32,019 total knee replacements in the Finnish Arthroplasty Register.

    PubMed

    Julin, Jaakko; Jämsen, Esa; Puolakka, Timo; Konttinen, Yrjö T; Moilanen, Teemu

    2010-08-01

    Total knee replacements (TKRs) are being increasingly performed in patients aged < or = 65 years who often have high physical demands. We investigated the relation between age of the patient and prosthesis survival following primary TKR using nationwide data collected from the Finnish Arthroplasty Register. From Jan 1, 1997 through Dec 31, 2003, 32,019 TKRs for primary or secondary osteoarthritis were reported to the Finnish Arthroplasty Register. The TKRs were followed until the end of 2004. During the follow-up, 909 TKRs were revised, 205 (23%) due to infection and 704 for other reasons. Crude overall implant survival improved with increasing age between the ages of 40 and 80. The 5-year survival rates were 92% and 95% in patients aged < or = 55 and 56-65 years, respectively, compared to 97% in patients who were > 65 years of age (p < 0.001). The difference was mainly attributable to reasons other than infections. Sex, diagnosis, type of TKR (condylar, constrained, or hinge), use of patellar component, and fixation method were also associated with higher revision rates. However, the differences in prosthesis survival between the age groups < or = 55, 56-65, and > 65 years remained after adjustment for these factors (p < 0.001). Young age impairs the prognosis of TKR and is associated with increased revision rates for non-infectious reasons. Diagnosis, sex, type of TKR, use of patellar component, and fixation method partly explain the differences, but the effects of physical activity, patient demands, and obesity on implant survival in younger patients warrant further research.

  3. Physical Function After Total Knee Replacement: An Observational Study Describing Outcomes in a Small Group of Women From China and the United States.

    PubMed

    White, Daniel K; Li, Zhichang; Zhang, Yuqing; Marmon, Adam R; Master, Hiral; Zeni, Joseph; Niu, Jingbo; Jiang, Long; Zhang, Shu; Lin, Jianhao

    2018-01-01

    To describe physical function before and six months after Total Knee Replacement (TKR) in a small sample of women from China and the United States. Observational. Community environment. Both groups adhered to the Osteoarthritis Research Society International (OARSI) protocols for the 6-minute walk and 30-second chair stand. We compared physical function prior to TKR and 6 months after using linear regression adjusted for covariates. Women (N=60) after TKR. Not applicable. Age and body mass index in the China group (n=30; 66y and 27.0kg/m 2 ) were similar to those in the U.S. group (n=30; 65y and 29.6kg/m 2 ). Before surgery, the China group walked 263 (95% confidence interval [CI], -309 to -219) less meters and had 10.2 (95% CI, -11.8 to -8.5) fewer chair stands than the U.S. group. At 6 months when compared with the U.S. group, the China group walked 38 more meters, but this difference did not reach statistical significance (95% CI, -1.6 to 77.4), and had 3.1 (95% CI, -4.4 to -1.7) fewer chair stands. The China group had greater improvement in the 6-minute walk test than did the U.S. group (P<.001). Despite having worse physical function before TKR, the China group had greater gains in walking endurance and similar gains in repeated chair stands than did the U.S. group after surgery. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. A biomechanical comparison of four different cementless press-fit stems used in revision surgery for total knee replacements.

    PubMed

    Zdero, Radovan; Saidi, Kevan; Mason, Stephanie A; Schemitsch, Emil H; Naudie, Douglas D R

    2012-11-01

    Few biomechanical studies exist on femoral cementless press-fit stems for revision total knee replacement (TKR) surgeries. The aim of this study was to compare the mechanical quality of the femur-stem interface for a series of commercially available press-fit stems, because this interface may be a 'weak link' which could fail earlier than the femur-TKR bond itself. Also, the femur-stem interface may become particularly critical if distal femur bone degeneration, which may necessitate or follow revision TKR, ever weakens the femur-TKR bond itself. The authors implanted five synthetic femurs each with a Sigma Short Stem (SSS), Sigma Long Stem (SLS), Genesis II Short Stem (GSS), or Genesis II Long Stem (GLS). Axial stiffness, lateral stiffness, 'offset load' torsional stiffness, and 'offset load' torsional strength were measured with a mechanical testing system using displacement control. Axial (range = 1047-1461 N/mm, p = 0.106), lateral (range = 415-462 N/mm, p = 0.297), and torsional (range = 115-139 N/mm, p > 0.055) stiffnesses were not different between groups. The SSS had higher torsional strength (863 N) than the other stems (range = 167-197 N, p < 0.001). Torsional failure occurred by femoral 'spin' around the stem's long axis. There was poor linear correlation between the femur-stem interface area versus axial stiffness (R = 0.38) and torsional stiffness (R = 0.38), and there was a moderate linear correlation versus torsional strength (R = 0.55). Yet, there was a high inverse linear correlation between interfacial surface area versus lateral stiffness (R = 0.79), although this did not result in a statistical difference between stem groups (p = 0.297). These press-fit stems provide equivalent stability, except that the SSS has greater torsional strength.

  5. Time-driven activity based costing of total knee replacement surgery at a London teaching hospital.

    PubMed

    Chen, Alvin; Sabharwal, Sanjeeve; Akhtar, Kashif; Makaram, Navnit; Gupte, Chinmay M

    2015-12-01

    The aim of this study was to conduct a time-driven activity based costing (TDABC) analysis of the clinical pathway for total knee replacement (TKR) and to determine where the major cost drivers lay. The in-patient pathway was prospectively mapped utilising a TDABC model, following 20 TKRs. The mean age for these patients was 73.4 years. All patients were ASA grade I or II and their mean BMI was 30.4. The 14 varus knees had a mean deformity of 5.32° and the six valgus knee had a mean deformity of 10.83°. Timings were prospectively collected as each patient was followed through the TKR pathway. Pre-operative costs including pre-assessment and joint school were £ 163. Total staff costs for admission and the operating theatre were £ 658. Consumables cost for the operating theatre were £ 1862. The average length of stay was 5.25 days at a total cost of £ 910. Trust overheads contributed £ 1651. The overall institutional cost of a 'noncomplex' TKR in patients without substantial medical co-morbidities was estimated to be £ 5422, representing a profit of £ 1065 based on a best practice tariff of £ 6487. The major cost drivers in the TKR pathway were determined to be theatre consumables, corporate overheads, overall ward cost and operating theatre staffing costs. Appropriate discounting of implant costs, reduction in length of stay by adopting an enhanced recovery programme and control of corporate overheads through the use of elective orthopaedic treatment centres are proposed approaches for reducing the overall cost of treatment. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Negative emotions affect postoperative scores for evaluating functional knee recovery and quality of life after total knee replacement.

    PubMed

    Qi, A; Lin, C; Zhou, A; Du, J; Jia, X; Sun, L; Zhang, G; Zhang, L; Liu, M

    2016-01-01

    This study aimed to determine whether psychological factors affect health-related quality of life (HRQL) and recovery of knee function in total knee replacement (TKR) patients. A total of 119 TKR patients (male: 38; female: 81) completed the Beck Anxiety Inventory (BAI), Beck Depression Inventory (BDI), State Trait Anxiety Inventory (STAI), Eysenck Personality Questionnaire-revised (EPQR-S), Knee Society Score (KSS), and HRQL (SF-36). At 1 and 6 months after surgery, anxiety, depression, and KSS scores in TKR patients were significantly better compared with those preoperatively (P<0.05). SF-36 scores at the sixth month after surgery were significantly improved compared with preoperative scores (P<0.001). Preoperative Physical Component Summary Scale (PCS) and Mental Component Summary Scale (MCS) scores were negatively associated with extraversion (E score) (B=-0.986 and -0.967, respectively, both P<0.05). Postoperative PCS and State Anxiety Inventory (SAI) scores were negatively associated with neuroticism (N score; B=-0.137 and -0.991, respectively, both P<0.05). Postoperative MCS, SAI, Trait Anxiety Inventory (TAI), and BAI scores were also negatively associated with the N score (B=-0.367, -0.107, -0.281, and -0.851, respectively, all P<0.05). The KSS function score at the sixth month after surgery was negatively associated with TAI and N scores (B=-0.315 and -0.532, respectively, both P<0.05), but positively associated with the E score (B=0.215, P<0.05). The postoperative KSS joint score was positively associated with postoperative PCS (B=0.356, P<0.05). In conclusion, for TKR patients, the scores used for evaluating recovery of knee function and HRQL after 6 months are inversely associated with the presence of negative emotions.

  7. The sociocultural effects on orthopedic surgeries in Taiwan

    PubMed Central

    Chiu, Shin-Lin; Chu, Chiao-Lee; Lan, Shou-Jen; Chen, Chiu-Liang

    2018-01-01

    Various sociocultural factors affect healthcare-seeking behaviors. In Taiwanese society, superstitions and lunar festivals play important roles in people’s lives. We investigated the impact of “Ghost Month” (the 7th lunar month) and Chinese New Year (the 12th lunar month and the 1st lunar month of the following year) on the number of elective surgeries and emergent surgeries in Taiwan. The number of total knee replacement (TKR) surgeries and proximal femur fracture (PFF) surgeries in each lunar month from 2000 to 2011 were extracted from the Taiwan National Health Insurance Database, a computerized and population-based database. Patients were then sorted by location of residence or gender. The average number of TKR surgeries performed was significantly lower during the 1st, 7th, and 12th lunar months in urban areas, whereas in rural areas this trend was only evident in the 7th and 12th lunar months. There was however, no significant difference in the average number of PFF surgeries in each lunar month except for an increase seen in the 1st lunar month in rural patients (p<0.05). When sorted by gender, the average number of TKR surgeries was significantly decreased in the 7th and 12th lunar months in male patients, and decreased in the 1st, 7th, and 12th lunar months in female patients. In contrast, there was no difference in the average numbers of PFF surgeries in the 7th and 12th lunar months either in male or female patients. We proposed that the timing of elective surgeries such as TKR might be influenced by Ghost Month and Chinese New Year; however, emergent PFF surgeries were not significantly influenced by sociocultural beliefs and taboos in Taiwan. PMID:29596539

  8. Sign-tracking predicts increased choice of cocaine over food in rats.

    PubMed

    Tunstall, Brendan J; Kearns, David N

    2015-03-15

    The purpose of this study was to determine whether the tendency to sign-track to a food cue was predictive of rats' choice of cocaine over food. First, rats were trained on a procedure where insertion of a retractable lever was paired with food. A sub-group of rats - sign-trackers - primarily approached and contacted the lever, while another sub-group - goal-trackers - approached the site of food delivery. Rats were then trained on a choice task where they could choose between an infusion of cocaine (1.0 mg/kg) and a food pellet (45 mg). Sign-trackers chose cocaine over food significantly more often than did goal-trackers. These results support the incentive-salience theory of addiction and add to a growing number of studies which suggest that sign-trackers may model an addiction-prone phenotype. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Treatment of Recurrent Hemarthrosis after Total Knee Arthroplasty

    PubMed Central

    Yoo, Ju-Hyung; Oh, Hyun-Cheol; Park, Sang-Hoon; Lee, Sanghyeon; Lee, Yunjae

    2018-01-01

    Purpose The purpose of this study is to evaluate the incidence and treatment of recurrent hemarthrosis after total knee replacement (TKR). Materials and Methods Among a total of 5,510 patients who underwent TKR from March 2000 to October 2016, patients who had two or more bleeding 2 weeks after surgery were studied. Conservative treatments were performed for all cases with symptoms. In patients who did not respond to conservative treatment several times, embolization was performed. We retrospectively evaluated the postoperative bleeding time, bleeding frequency, treatment method, and outcome. Results Seventeen (0.3%) of the 5,510 patients developed recurrent hemarthrosis. Bleeding occurred at an average of 2 years 3 months after the operation. Joint aspiration was performed 3.5 times (range, 2 to 10 times) on average, and 14 cases (82.3%) were treated with conservative treatment. In 3 patients with severe bleeding and hemorrhage, embolization was performed. Conclusions Recurrent hemarthrosis after TKR is a rare disease with a low incidence of 0.3% and usually could be treated by conservative treatment. If recurrences occur repeatedly, embolization through angiography or surgical treatment may be considered, but the results are not satisfactory and careful selection of treatment modalities is warranted. PMID:29715715

  10. Splash in elective primary knee and hip replacement: are we adequately protected?

    PubMed

    Singh, V K; Kalairajah, Y

    2009-08-01

    An intra-operative splash is a common occurrence in elective knee and hip replacement surgery and can potentially transmit bloodborne diseases, with devastating consequences. This study aimed to quantify the risk of a splash and to assess its correlation with body mass index, duration of surgery and the volume of lavage fluid used. Between December 2007 and April 2008, 62 consecutive patients (38 women, 24 men) undergoing an elective total knee or total hip replacement (TKR, THR) were recruited into the study (32 TKRs and 30 THRs) after appropriate consent. A splash occurred in all 62 cases. A THR had a slightly higher risk of a splash than a TKR, but this was not statistically significant (p = 0.27). The correlation between body mass index, duration of surgery and the amount of pulse lavage used with a splash was r = 0.013, (non-significant), r = 0.52, (significant) and r = 0.92 (highly significant), respectively. A high number of splashes are generated during a TKR and a THR. The simple visor mask fails to protect the surgeon, the assistant or the patient from the risk of a splash and reverse splash, respectively.

  11. Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology, and peri-implant cytokine expression pattern.

    PubMed

    Thomas, Peter; von der Helm, Christine; Schopf, Christoph; Mazoochian, Farhad; Frommelt, Lars; Gollwitzer, Hans; Schneider, Josef; Flaig, Michael; Krenn, Veit; Thomas, Benjamin; Summer, Burkhard

    2015-01-01

    We performed a combined approach to identify suspected allergy to knee arthroplasty (TKR): patch test (PT), lymphocyte transformation test (LTT), histopathology (overall grading; T- and B-lymphocytes, macrophages, and neutrophils), and semiquantitative Real-time-PCR-based periprosthetic inflammatory mediator analysis (IFNγ, TNFα, IL1-β, IL-2, IL-6, IL-8, IL-10, IL17, and TGFβ). We analyzed 25 TKR patients with yet unexplained complications like pain, effusion, and reduced range of motion. They consisted of 20 patients with proven metal sensitization (11 with PT reactions; 9 with only LTT reactivity). Control specimens were from 5 complicated TKR patients without metal sensitization, 12 OA patients before arthroplasty, and 8 PT patients without arthroplasty. Lymphocytic infiltrates were seen and fibrotic (Type IV membrane) tissue response was most frequent in the metal sensitive patients, for example, in 81% of the PT positive patients. The latter also had marked periprosthetic IFNγ expression. 8/9 patients with revision surgery using Ti-coated/oxinium based implants reported symptom relief. Our findings demonstrate that combining allergy diagnostics with histopathology and periprosthetic cytokine assessment could allow us to design better diagnostic strategies.

  12. Comparison of intramedullary nailing and external fixation knee arthrodesis for the infected knee replacement.

    PubMed

    Mabry, Tad M; Jacofsky, David J; Haidukewych, George J; Hanssen, Arlen D

    2007-11-01

    We analyzed knee arthrodesis for the infected total knee replacement (TKR) using two different fixation techniques. Patients undergoing knee arthrodesis for infected TKR were identified and rates of successful fusion and recurrence of infection were compared using Cox proportional hazard models. Eighty-five consecutive patients who underwent knee arthrodesis were followed until union, nonunion, amputation, or death. External fixation achieved successful fusion in 41 of 61 patients and was associated with a 4.9% rate of deep infection. Fusion was successful in 23 of 24 patients with intramedullary (IM) nailing and was associated with an 8.3% rate of deep infection. We observed similar fusion and infection rates with the two techniques. Thirty-four patients (40%) had complications. Knee arthrodesis remains a reasonable salvage alternative for the difficult infected TKR. Complication rates are high irrespective of the technique, and one must consider the risks of both nonunion and infection when choosing the fixation method in this setting. IM nailing appears to have a higher rate of successful union but a higher risk of recurrent infection when compared with external fixation knee arthrodesis. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  13. The Effect of Music Listening on Pain, Heart Rate Variability, and Range of Motion in Older Adults After Total Knee Replacement.

    PubMed

    Hsu, Chih-Chung; Chen, Su-Ru; Lee, Pi-Hsia; Lin, Pi-Chu

    2017-12-01

    The purpose of this study was to investigate the effects that listening and not listening to music had on pain relief, heart rate variability (HRV), and knee range of motion in total knee replacement (TKR) patients who underwent continuous passive motion (CPM) rehabilitation. We adopted a single-group quasi-experimental design. A sample of 49 TKR patients listened to music for 25 min during one session of CPM and no music during another session of CPM the same day for a total of 2 days. Results indicated that during CPM, patients exhibited a significant decrease in the pain level ( p < .05), an increase in the CPM knee flexion angle ( p < .05), a decrease in the low-frequency/high-frequency ratio (LF/HF) and normalized LF (nLF) of the HRV ( p < .01), and an increase in the normalized HF (nHF) and standard deviation of all normal-to-normal intervals (SDNN; p < .01) when listening to music compared with no music. This study demonstrated that listening to music can effectively decrease pain during CPM rehabilitation and improve the joint range of motion in patients who underwent TKR surgery.

  14. [Relative effect per patient (REPP)--outcome groups for total hip replacement and total knee replacement].

    PubMed

    Huber, J; Dabis, E; Zumstein, M D; Hüsler, J

    2013-06-01

    The outcome of orthopaedic surgery such as total hip replacement (THR) or total knee replacement (TKR) is commonly given by the change in mean scores on patient-reported outcome measures (Prom's). This may give the impression that all enrolled patients have experienced an improvement. But the Swedish hip registry and other studies report a reduction of complaints in 80-85 % of patients ("responders"), with the remainder (approximately one in six) remaining unchanged or reporting worse complaints ("non-responders"). According to Cohen, the degree of success in the "responders" group can be subdivided into excellent, good and moderate. For a given treatment, a total of 5 different outcome groups can therefore be defined: excellent, good, moderate, unchanged and worse. Allocation to the groups is based on the "relative effect per patient" (REPP). The REPP is calculated as the base-line score minus the post-treatment score divided by the baseline score. The maximum possible REPP is 1; a REPP of 0 means no effect and a negative REPP means deterioration. Allocation to the outcome groups is as follows: excellent 0.95 to 1 REPP, good 0.5 to 0.95 REPP, moderate over 0.2 to 0.5 REPP, unchanged -0.2 to 0.2 REPP and worse below -0.2 REPP. Our local arthroplasty register was used to evaluate the 1-year outcomes of THR and TKR patients operated between March 2003 and November 2008, using WOMAC scores and EuroQoL scores. Only patients with complete data sets and unilateral THR/TKR were included. The success rate given by the REPP method was compared with that of the "responder rate" method defined by the OMERACT-OARSI criteria. With the WOMAC questionnaire, outcomes were as follows (THR/TKR): excellent 29/14 %, good 51/54 %, moderate 11/13 %, unchanged at 5/12 %, worse 4/7 %. The corresponding values for the EuroQoL were (THR/TKR): excellent 16/6 %, good 41/42 %, moderate 25/28 %, unchanged 12/16 %, worse 6/8 %. For THR, success rates were 92 % using the "responder rate" method (OMERACT-OARSI criteria) and 91 % using the REPP method with the WOMAC. Calculation of the REPP and the subsequent allocation to outcome groups is simple. The distribution of outcomes depends on the intervention (THR results better than TKR) and the patient questionnaire used (better results with a condition-specific than a generic questionnaire). The proportion of "unchanged" and "moderate" outcomes was greater with the generic questionnaire than with the condition-specific questionnaire, while the proportion of "worse" outcomes was similar for the two instruments. Partitioning of the degree of success into sub-groups, based on the REPP, provides more information for both the patient and the orthopaedic surgeon. Georg Thieme Verlag KG Stuttgart · New York.

  15. FGFR a promising druggable target in cancer: Molecular biology and new drugs.

    PubMed

    Porta, Rut; Borea, Roberto; Coelho, Andreia; Khan, Shahanavaj; Araújo, António; Reclusa, Pablo; Franchina, Tindara; Van Der Steen, Nele; Van Dam, Peter; Ferri, Jose; Sirera, Rafael; Naing, Aung; Hong, David; Rolfo, Christian

    2017-05-01

    The Fibroblast Growth Factor Receptor (FGFR) family consists of Tyrosine Kinase Receptors (TKR) involved in several biological functions. Recently, alterations of FGFR have been reported to be important for progression and development of several cancers. In this setting, different studies are trying to evaluate the efficacy of different therapies targeting FGFR. This review summarizes the current status of treatments targeting FGFR, focusing on the trials that are evaluating the FGFR profile as inclusion criteria: Multi-Target, Pan-FGFR Inhibitors and anti-FGF (Fibroblast Growth Factor)/FGFR Monoclonal Antibodies. Most of the TKR share intracellular signaling pathways; therefore, cancer cells tend to overcome the inhibition of one tyrosine kinase receptor by activating another. The future of TKI (Tyrosine Kinase Inhibitor) therapy will potentially come from multi-targeted TKIs that target different TKR simultaneously. It is crucial to understand the interaction of the FGF-FGFR axis with other known driver TKRs. Based on this, it is possible to develop therapeutic strategies targeting multiple connected TKRs at once. One correct step in this direction is the reassessment of multi target inhibitors considering the FGFR status of the tumor. Another opportunity arises from assessing the use of FGFR TKI on patients harboring FGFR alterations. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety.

    PubMed

    Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj

    2015-01-01

    Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p < 0.05). Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p < 0.0001). There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p < 0.05). Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time.

  17. The optimal protocol to reduce blood loss and blood transfusion after unilateral total knee replacement: Low-dose IA-TXA plus 30-min drain clamping versus drainage clamping for the first 3 h without IA-TXA.

    PubMed

    Park, Joo Hyun; Choi, Sung Wook; Shin, Eun Ho; Park, Myung Hoon; Kim, Myung Ku

    2017-01-01

    Although intraarticular tranexamic acid (IA-TXA) administration or drainage clamping are popular methods used to reduce blood loss after total knee replacement (TKR), the protocol remains controversial. We aimed (1) to establish new protocols through investigating whether two methods, that is, low-dose (500 mg) IA-TXA plus 30-min drain clamping and drainage clamping for the first 3 h without IA-TXA, can reduce blood loss and blood transfusion after unilateral TKR and (2) to make recommendations related to clinical application. This study, conducted from September 2014 to June 2016 related to enrolled 95 patients with primary osteoarthritis who were to have a unilateral cemented TKR, was nonrandomized and retrospective. In group A, the drain was released following tourniquet deflation. In group B, 500-mg TXA was injected into the knee joint via a drain tube after fascia closure and the drain was clamped for the first 30 min to prevent leakage. In group C, the drain was clamped for the first 3-h postoperation. Demographic characteristics and clinical data were collected, including the levels of hematocrit (Hct), the total blood loss (TBL), drained blood volume (BV), the amount of blood transfused, and any complications that developed. We found a significantly lower postoperative TBL, drained BV, decreasing Hct level, and less transfused BV in the IA-TXA injection group (group B) and the 3-h drainage clamping group (group C) compared to the conventional negative drainage group (group A; p < 0.001). There was no significant difference between groups B and C ( p = 0.99). The drainage clamping method can be safer than IA-TXA administration in patients with risk factor of venous thromboembolic complication. Furthermore, the IA-TXA administration can be more optimal than drainage clamping in patients with high bleeding tendency or lateral retinacular release during TKR, who would be concerned about postoperative wound complication.

  18. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    PubMed

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, p<0.001) and 4MGS (r=-0.583, p=0.003). This study demonstrates excellent inter-observer and test-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Does the person's context influence engagement in life activities following primary knee replacement? Results from a Canadian prospective cohort study.

    PubMed

    Davis, Aileen M; Venkataramanan, Viji; Bytautas-Sillanpää, Jessica; Perruccio, Anthony V; Wong, Rosalind; Carlesso, Lisa; Webster, Fiona

    2017-08-18

    The impact of the context of a person's life on recovery from surgical interventions is not well understood. This study evaluated if people's social, environmental and biomedical context was associated with change in frequency in engagement in life activities after total knee replacement (TKR). 418 people aged 30+ years who had TKR were followed presurgery to 1 year postsurgery. The outcome was change in frequency in engagement in life activities measured by the Late Life Disability Index (LLDI). Predictor variables of interest evaluated in multivariable linear regression analysis were positive and negative life events (Life Experiences Survey), development of a new comorbidity, another joint replacement and complications after TKR surgery. Mean age was 65 years, 36% were male; 22% and 21% had no comorbidity presurgery and postsurgery. Presurgery LLDI frequency was 69.6 (±11.4) and the mean change was 6.1 (±10.2). Thirty-four per cent and 65% reported at least one positive or negative life event. Seven per cent developed hypertension, 6% cardiovascular disease, 2% lung disease and 2% diabetes. Eleven per cent had a complication and 9% another hip or knee replaced. Smaller changes in LLDI frequency were associated with more negative life events (beta=-0.56; 95% CI -0.92 to-0.18) and complications (beta=-4.01; 95% CI -6.63 to -1.38) after adjusting for age, sex, education, body mass index, comorbidities presurgery, number of symptomatic joints and knee-specific pain and function, LLDI limitations and depression. A new comorbidity or another joint replacement was not associated with outcome in unadjusted or adjusted analysis. Multifaceted life experiences shape the context of peoples' lives impacting their engagement in activities important for healthy living post-TKR. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Muon trackers for imaging a nuclear reactor

    NASA Astrophysics Data System (ADS)

    Kume, N.; Miyadera, H.; Morris, C. L.; Bacon, J.; Borozdin, K. N.; Durham, J. M.; Fuzita, K.; Guardincerri, E.; Izumi, M.; Nakayama, K.; Saltus, M.; Sugita, T.; Takakura, K.; Yoshioka, K.

    2016-09-01

    A detector system for assessing damage to the cores of the Fukushima Daiichi nuclear reactors by using cosmic-ray muon tomography was developed. The system consists of a pair of drift-tube tracking detectors of 7.2× 7.2-m2 area. Each muon tracker consists of 6 x-layer and 6 y-layer drift-tube detectors. Each tracker is capable of measuring muon tracks with 12 mrad angular resolutions, and is capable of operating under 50-μ Sv/h radiation environment by removing gamma induced background with a novel time-coincidence logic. An estimated resolution to observe nuclear fuel debris at Fukushima Daiichi is 0.3 m when the core is imaged from outside the reactor building.

  1. Which cue to ‘want’? Opioid stimulation of central amygdala makes goal-trackers show stronger goal-tracking, just as sign-trackers show stronger sign-tracking

    PubMed Central

    DiFeliceantonio, Alexandra G.; Berridge, Kent C.

    2012-01-01

    Pavlovian cues that have been paired with reward can gain incentive salience. Drug addicts find drug cues motivationally attractive and binge eaters are attracted by food cues. But the level of incentive salience elicited by a cue re-encounter still varies across time and brain states. In an animal model, cues become attractive and ‘wanted’ in an ‘autoshaping’ paradigm, where different targets of incentive salience emerge for different individuals. Some individuals (sign-trackers) find a predictive discrete cue attractive while others find a reward contiguous and goal cue more attractive (location where reward arrives: goal-trackers). Here we assessed whether central amygdala mu opioid receptor stimulation enhances the phasic incentive salience of the goal-cue for goal-trackers during moments of predictive cue presence (expressed in both approach and consummatory behaviors to goal cue), just as it enhances the attractiveness of the predictive cue target for sign-trackers. Using detailed video analysis we measured the approaches, nibbles, sniffs, and bites directed at their preferred target for both sign-trackers and goal-trackers. We report that DAMGO microinjections in central amygdala made goal-trackers, like sign-trackers, show phasic increases in appetitive nibbles and sniffs directed at the goal-cue expressed selectively whenever the predictive cue was present. This indicates enhancement of incentive salience attributed by both goal trackers and sign-trackers, but attributed in different directions: each to their own target cue. For both phenotypes, amygdala opioid stimulation makes the individual’s prepotent cue into a stronger motivational magnet at phasic moments triggered by a CS that predicts the reward UCS. PMID:22391118

  2. Individual differences in the influence of task-irrelevant Pavlovian cues on human behavior.

    PubMed

    Garofalo, Sara; di Pellegrino, Giuseppe

    2015-01-01

    Pavlovian-to-instrumental transfer (PIT) refers to the process of a Pavlovian reward-paired cue acquiring incentive motivational proprieties that drive choices. It represents a crucial phenomenon for understanding cue-controlled behavior, and it has both adaptive and maladaptive implications (i.e., drug-taking). In animals, individual differences in the degree to which such cues bias performance have been identified in two types of individuals that exhibit distinct Conditioned Responses (CR) during Pavlovian conditioning: Sign-Trackers (ST) and Goal-Trackers (GT). Using an appetitive PIT procedure with a monetary reward, the present study investigated, for the first time, the extent to which such individual differences might affect the influence of reward-paired cues in humans. In a first task, participants learned an instrumental response leading to reward; then, in a second task, a visual Pavlovian cue was associated with the same reward; finally, in a third task, PIT was tested by measuring the preference for the reward-paired instrumental response when the task-irrelevant reward-paired cue was presented, in the absence of the reward itself. In ST individuals, but not in GT individuals, reward-related cues biased behavior, resulting in an increased likelihood to perform the instrumental response independently paired with the same reward when presented with the task-irrelevant reward-paired cue, even if the reward itself was no longer available (i.e., stronger PIT effect). This finding has important implications for developing individualized treatment for maladaptive behaviors, such as addiction.

  3. Individual differences in the influence of task-irrelevant Pavlovian cues on human behavior

    PubMed Central

    Garofalo, Sara; di Pellegrino, Giuseppe

    2015-01-01

    Pavlovian-to-instrumental transfer (PIT) refers to the process of a Pavlovian reward-paired cue acquiring incentive motivational proprieties that drive choices. It represents a crucial phenomenon for understanding cue-controlled behavior, and it has both adaptive and maladaptive implications (i.e., drug-taking). In animals, individual differences in the degree to which such cues bias performance have been identified in two types of individuals that exhibit distinct Conditioned Responses (CR) during Pavlovian conditioning: Sign-Trackers (ST) and Goal-Trackers (GT). Using an appetitive PIT procedure with a monetary reward, the present study investigated, for the first time, the extent to which such individual differences might affect the influence of reward-paired cues in humans. In a first task, participants learned an instrumental response leading to reward; then, in a second task, a visual Pavlovian cue was associated with the same reward; finally, in a third task, PIT was tested by measuring the preference for the reward-paired instrumental response when the task-irrelevant reward-paired cue was presented, in the absence of the reward itself. In ST individuals, but not in GT individuals, reward-related cues biased behavior, resulting in an increased likelihood to perform the instrumental response independently paired with the same reward when presented with the task-irrelevant reward-paired cue, even if the reward itself was no longer available (i.e., stronger PIT effect). This finding has important implications for developing individualized treatment for maladaptive behaviors, such as addiction. PMID:26157371

  4. Muon trackers for imaging a nuclear reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kume, N.; Miyadera, H.; Morris, C. L.

    A detector system for assessing damage to the cores of the Fukushima Daiichi nuclear reactors by using cosmic-ray muon tomography was developed. Furthermore, the system consists of a pair of drift-tube tracking detectors of 7.2× 7.2-m 2 area. In each muon tracker there consists 6 x-layer and 6 y-layer drift-tube detectors. Each tracker is capable of measuring muon tracks with 12 mrad angular resolutions, and is capable of operating under 50-μ Sv/h radiation environment by removing gamma induced background with a novel time-coincidence logic. An estimated resolution to observe nuclear fuel debris at Fukushima Daiichi is 0.3 m when themore » core is imaged from outside the reactor building.« less

  5. Muon trackers for imaging a nuclear reactor

    DOE PAGES

    Kume, N.; Miyadera, H.; Morris, C. L.; ...

    2016-09-21

    A detector system for assessing damage to the cores of the Fukushima Daiichi nuclear reactors by using cosmic-ray muon tomography was developed. Furthermore, the system consists of a pair of drift-tube tracking detectors of 7.2× 7.2-m 2 area. In each muon tracker there consists 6 x-layer and 6 y-layer drift-tube detectors. Each tracker is capable of measuring muon tracks with 12 mrad angular resolutions, and is capable of operating under 50-μ Sv/h radiation environment by removing gamma induced background with a novel time-coincidence logic. An estimated resolution to observe nuclear fuel debris at Fukushima Daiichi is 0.3 m when themore » core is imaged from outside the reactor building.« less

  6. Evaluation of the relationship between anteroposterior translation of a posterior cruciate ligament-retaining total knee replacement and functional outcome.

    PubMed

    Seah, R B; Pang, H N; Lo, N N; Chong, H C; Chin, P L; Chia, S L; Yeo, S J

    2012-10-01

    The success of total knee replacement (TKR) depends on optimal soft-tissue balancing, among many other factors. The objective of this study is to correlate post-operative anteroposterior (AP) translation of a posterior cruciate ligament-retaining TKR with clinical outcome at two years. In total 100 patients were divided into three groups based on their AP translation as measured by the KT-1000 arthrometer. Group 1 patients had AP translation < 5 mm, Group 2 had AP translation from 5 mm to 10 mm, and Group 3 had AP translation > 10 mm. Outcome assessment included range of movement of the knee, the presence of flexion contractures, hyperextension, knee mechanical axes and functional outcome using the Knee Society score, Oxford knee score and the Short-Form 36 questionnaire. At two years, patients in Group 2 reported significantly better Oxford knee scores than the other groups (p = 0.045). A positive correlation between range of movement and AP translation was noted, with patients in group 3 having the greatest range of movement (mean flexion: 117.9° (106° to 130°)) (p < 0.001). However, significantly more patients in Group 3 developed hyperextension > 10° (p = 0.01). In this study, the best outcome for cruciate-ligament retaining TKR was achieved in patients with an AP translation of 5 mm to 10 mm.

  7. A comparison of registration errors with imageless computer navigation during MIS total knee arthroplasty versus standard incision total knee arthroplasty: a cadaveric study.

    PubMed

    Davis, Edward T; Pagkalos, Joseph; Gallie, Price A M; Macgroarty, Kelly; Waddell, James P; Schemitsch, Emil H

    2015-01-01

    Optimal component alignment in total knee arthroplasty has been associated with better functional outcome as well as improved implant longevity. The ability to align components optimally during minimally invasive (MIS) total knee replacement (TKR) has been a cause of concern. Computer navigation is a useful aid in achieving the desired alignment although it is limited by the error during the manual registration of landmarks. Our study aims to compare the registration process error between a standard and a MIS surgical approach. We hypothesized that performing the registration error via an MIS approach would increase the registration process error. Five fresh frozen lower limbs were routinely prepared and draped. The registration process was performed through an MIS approach. This was then extended to the standard approach and the registration was performed again. Two surgeons performed the registration process five times with each approach. Performing the registration process through the MIS approach was not associated with higher error compared to the standard approach in the alignment parameters of interest. This rejects our hypothesis. Image-free navigated MIS TKR does not appear to carry higher risk of component malalignment due to the registration process error. Navigation can be used during MIS TKR to improve alignment without reduced accuracy due to the approach.

  8. An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety

    PubMed Central

    Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj

    2015-01-01

    Background. Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. Materials and Methods. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. Results. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p < 0.05). Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p < 0.0001). There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p < 0.05).  Conclusions. Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time. PMID:26583092

  9. Increased conformity offers diminishing returns for reducing total knee replacement wear.

    PubMed

    Fregly, Benjamin J; Marquez-Barrientos, Carlos; Banks, Scott A; DesJardins, John D

    2010-02-01

    Wear remains a significant problem limiting the lifespan of total knee replacements (TKRs). Though increased conformity between TKR components has the potential to decrease wear, the optimal amount and planes of conformity have not been investigated. Furthermore, differing conformities in the medial and lateral compartments may provide designers the opportunity to address both wear and kinematic design goals simultaneously. This study used a computational model of a Stanmore knee simulator machine and a previously validated wear model to investigate this issue for simulated gait. TKR geometries with different amounts and planes of conformity on the medial and lateral sides were created and tested in two phases. The first phase utilized a wide range of sagittal and coronal conformity combinations to blanket a physically realistic design space. The second phase performed a focused investigation of the conformity conditions from the first phase to which predicted wear volume was sensitive. For the first phase, sagittal but not coronal conformity was found to have a significant effect on predicted wear volume. For the second phase, increased sagittal conformity was found to decrease predicted wear volume in a nonlinear fashion, with reductions gradually diminishing as conformity increased. These results suggest that TKR geometric design efforts aimed at minimizing wear should focus on sagittal rather than coronal conformity and that at least moderate sagittal conformity is desirable in both compartments.

  10. Fibrin tissue adhesive reduces postoperative blood loss in total knee arthroplasty.

    PubMed

    Sabatini, Luigi; Trecci, Andrea; Imarisio, Daniele; Uslenghi, Marco Davide; Bianco, Giuseppe; Scagnelli, Roberto

    2012-09-01

    Blood transfusion is often required in total knee replacement; various methods of blood preservation have been studied. The best solution is to reduce the loss of blood during and after surgery. We designed this study to evaluate the hemostatic efficacy and safety of fibrin tissue adhesive (Quixil) in patients receiving total knee arthroplasty [low contact stress (LCS, DePuy, Warsaw, IN, US) cementless total knee replacement (TKR)] with a prospective, randomized, standard treatment controlled study. Thirty-five patients were randomized to receive treatment with fibrin tissue adhesive (treatment group), and 35 were randomized to be managed with postoperative blood recovery and reinfusion (control group). Blood loss in suction drain, decrease in hemoglobin values, and transfusions were recorded. A significant reduction in apparent total blood loss was detected in the treatment group compared with the control group. There was also a lower decrease in hemoglobin level, although this difference was not significant. When fibrin tissue adhesive was administered, the need for transfusions was lower. No major adverse events were recorded in our series. Fibrin tissue adhesive reduced blood loss in TKR and seemed to significantly reduce the need for blood transfusion. Fibrin tissue adhesive can be an appropriate solution to enhance hemostasis and vessel sealing at the operative site in TKR, in order to reduce blood loss after surgery and the risk of complications.

  11. Balance Training With a Dynamometric Platform Following Total Knee Replacement: A Randomized Controlled Trial.

    PubMed

    Roig-Casasús, Sergio; María Blasco, José; López-Bueno, Laura; Blasco-Igual, María Clara

    2017-03-01

    Sensorimotor training has proven to be an efficient approach for recovering balance control following total knee replacement (TKR). The purpose of this trial was to evaluate the influence of specific balance-targeted training using a dynamometric platform on the overall state of balance in older adults undergoing TKR. This was a randomized controlled clinical trial conducted at a university hospital rehabilitation unit. Patients meeting the inclusion criteria were randomly assigned to a control group or an experimental group. Both groups participated in the same 4-week postoperative rehabilitation training protocol. Participants in the experimental group performed additional balance training with a dynamometric platform consisting of tests related to stability challenges, weight-shifting, and moving to the limits of stability. The primary outcome measure was the overall state of balance rated according to the Berg Balance Scale. Secondary outcomes in terms of balance were the Timed Up and Go Test, Functional Reach Test, and Romberg open and closed-eyes tests. Data processing included between-group analysis of covariance, minimal detectable change assessment for the primary outcome measure, and effect size estimation. Confidence intervals (CIs) were set at 95%. Forty-three participants meeting the inclusion criteria and having signed the informed consent were randomly assigned to 2 groups. Thirty-seven completed the training (86.1%). Significant between-group differences in balance performance were found as measured with the Berg Balance Scale (P = .03) and Functional Reach Test (P = .04) with a CI = 95%. Significant differences were not recorded for the Timed Up and Go Test or Romberg open and closed-eyes tests (P > .05). Furthermore, Cohen's effect size resulted in a value of d = 0.97, suggesting a high practical significance of the trial. According to the Berg Balance Scale and Functional Reach Test, participants with TKR who have followed a 4-week training program using a dynamometric platform improved balance performance to a higher extent than a control group training without such a device. The inclusion of this instrument in the functional training protocol may be beneficial for recovering balance following TKR.

  12. Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data

    NASA Astrophysics Data System (ADS)

    Tykhonov, A.; Ambrosi, G.; Asfandiyarov, R.; Azzarello, P.; Bernardini, P.; Bertucci, B.; Bolognini, A.; Cadoux, F.; D'Amone, A.; De Benedittis, A.; De Mitri, I.; Di Santo, M.; Dong, Y. F.; Duranti, M.; D'Urso, D.; Fan, R. R.; Fusco, P.; Gallo, V.; Gao, M.; Gargano, F.; Garrappa, S.; Gong, K.; Ionica, M.; La Marra, D.; Lei, S. J.; Li, X.; Loparco, F.; Marsella, G.; Mazziotta, M. N.; Peng, W. X.; Qiao, R.; Salinas, M. M.; Surdo, A.; Vagelli, V.; Vitillo, S.; Wang, H. Y.; Wang, J. Z.; Wang, Z. M.; Wu, D.; Wu, X.; Zhang, F.; Zhang, J. Y.; Zhao, H.; Zimmer, S.

    2018-06-01

    The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m2. Silicon planes are interleaved with three layers of tungsten plates, resulting in about one radiation length of material in the tracker. Internal alignment parameters of the tracker have been determined on orbit, with non-showering protons and helium nuclei. We describe the alignment procedure and present the position resolution and alignment stability measurements.

  13. Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed.

    PubMed

    Fokkema, Tryntsje; Kooiman, Thea J M; Krijnen, Wim P; VAN DER Schans, Cees P; DE Groot, Martijn

    2017-04-01

    To examine the test-retest reliability and validity of ten activity trackers for step counting at three different walking speeds. Thirty-one healthy participants walked twice on a treadmill for 30 min while wearing 10 activity trackers (Polar Loop, Garmin Vivosmart, Fitbit Charge HR, Apple Watch Sport, Pebble Smartwatch, Samsung Gear S, Misfit Flash, Jawbone Up Move, Flyfit, and Moves). Participants walked three walking speeds for 10 min each; slow (3.2 km·h), average (4.8 km·h), and vigorous (6.4 km·h). To measure test-retest reliability, intraclass correlations (ICC) were determined between the first and second treadmill test. Validity was determined by comparing the trackers with the gold standard (hand counting), using mean differences, mean absolute percentage errors, and ICC. Statistical differences were calculated by paired-sample t tests, Wilcoxon signed-rank tests, and by constructing Bland-Altman plots. Test-retest reliability varied with ICC ranging from -0.02 to 0.97. Validity varied between trackers and different walking speeds with mean differences between the gold standard and activity trackers ranging from 0.0 to 26.4%. Most trackers showed relatively low ICC and broad limits of agreement of the Bland-Altman plots at the different speeds. For the slow walking speed, the Garmin Vivosmart and Fitbit Charge HR showed the most accurate results. The Garmin Vivosmart and Apple Watch Sport demonstrated the best accuracy at an average walking speed. For vigorous walking, the Apple Watch Sport, Pebble Smartwatch, and Samsung Gear S exhibited the most accurate results. Test-retest reliability and validity of activity trackers depends on walking speed. In general, consumer activity trackers perform better at an average and vigorous walking speed than at a slower walking speed.

  14. The older worker with osteoarthritis of the knee.

    PubMed

    Palmer, Keith T

    2012-06-01

    Changing demographics mean that many patients with large joint arthritis will work beyond traditional retirement age. This review considers the impact of knee osteoarthritis (OA) on work participation and the relation between work and total knee replacement (TKR). Two systematic searches in Embase and Medline, supplemented by three systematic reviews. Probably, although evidence is limited, knee OA considerably impairs participation in work (labour force participation, work attendance and work productivity). AREAS OF UNCERTAINTY/RESEARCH NEED: Little is known about effective interventions (treatments, work changes and policies) to improve vocational participation in patients with knee OA; or how type of work affects long-term clinical outcomes (e.g. pain, function and the need for revision surgery) in patients with TKRs. The need for such research is pressing and opportune, as increasing numbers of patients with knee OA or TKR expect to work on.

  15. Audit on the Efficient Use of Cross-Matched Blood in Elective Total Hip and Total Knee Replacement

    PubMed Central

    Rogers, BA; Johnstone, DJ

    2006-01-01

    INTRODUCTION This prospective audit studies the use of cross-matched blood in 301 patients over a 1-year period undergoing total knee (TKR) and total hip replacement (THR) surgery in an orthopaedic unit. PATIENTS AND METHODS Analysis over the first 6 months revealed a high level of unnecessary cross-matched blood. The following interventions were introduced: (i) to cease routine cross-matching for THR; (ii) all patients to have a check full blood count on day 2 after surgery; and (iii) Hb < 8 g/dl to be considered as the trigger for transfusion in patients over 65 years and free from significant co-morbidity. These changes are in accordance with published national guidelines [Anon. Guidelines for the clinical use of red cell transfusions. Br J Haematol 2001; 113: 24–31]. RESULTS In the next 6 months, the number of units cross-matched but not transfused fell by 96% for THR, and the cross-match transfusion (C:T) ratio reduced from 3.21 to 1.62. Reductions were also observed for the TKR cohort. These results provide evidence of a substantial risk and cost benefit in the use of this limited resource. A telephone survey of 44 hospitals revealed that 20 hospitals routinely cross-matched blood for THR and 11 do so for TKR. CONCLUSIONS Changes can be made to the Maximum Surgical Blood Ordering Schedules (MSBOS) in other orthopaedic units according to national guidelines. PMID:16551419

  16. The risk of venous thromboembolism, myocardial infarction, stroke, major bleeding and death in patients undergoing total hip and knee replacement: a 15-year retrospective cohort study of routine clinical practice.

    PubMed

    Pedersen, A B; Mehnert, F; Sorensen, H T; Emmeluth, C; Overgaard, S; Johnsen, S P

    2014-04-01

    We examined the risk of thrombotic and major bleeding events in patients undergoing total hip and knee replacement (THR and TKR) treated with thromboprophylaxis, using nationwide population-based databases. We identified 83 756 primary procedures performed between 1997 and 2011. The outcomes were symptomatic venous thromboembolism (VTE), myocardial infarction (MI), stroke, death and major bleeding requiring hospitalisation within 90 days of surgery. A total of 1114 (1.3%) and 483 (0.6%) patients experienced VTE and bleeding, respectively. The annual risk of VTE varied between 0.9% and 1.6%, and of bleeding between 0.4% and 0.8%. The risk of VTE and bleeding was unchanged over a 15-year period. A total of 0.7% of patients died within 90 days, with a decrease from 1% in 1997 to 0.6% in 2011 (p < 0.001). A high level of comorbidity and general anaesthesia were strong risk factors for both VTE and bleeding, with no difference between THR and TKR patients. The risk of both MI and stroke was 0.5%, which remained unchanged during the study period. In this cohort study of patients undergoing THR and TKR patients in routine clinical practice, approximately 3% experienced VTE, MI, stroke or bleeding. These risks did not decline during the 15-year study period, but the risk of dying fell substantially.

  17. Cellular and molecular insight into the inhibition of primary root growth of Arabidopsis induced by peptaibols, a class of linear peptide antibiotics mainly produced by Trichoderma spp.

    PubMed

    Shi, Wei-Ling; Chen, Xiu-Lan; Wang, Li-Xia; Gong, Zhi-Ting; Li, Shuyu; Li, Chun-Long; Xie, Bin-Bin; Zhang, Wei; Shi, Mei; Li, Chuanyou; Zhang, Yu-Zhong; Song, Xiao-Yan

    2016-04-01

    Trichoderma spp. are well known biocontrol agents that produce a variety of antibiotics. Peptaibols are a class of linear peptide antibiotics mainly produced by Trichoderma Alamethicin, the most studied peptaibol, is reported as toxic to plants at certain concentrations, while the mechanisms involved are unclear. We illustrated the toxic mechanisms of peptaibols by studying the growth-inhibitory effect of Trichokonin VI (TK VI), a peptaibol from Trichoderma longibrachiatum SMF2, on Arabidopsis primary roots. TK VI inhibited root growth by suppressing cell division and cell elongation, and disrupting root stem cell niche maintenance. TK VI increased auxin content and disrupted auxin response gradients in root tips. Further, we screened the Arabidopsis TK VI-resistant mutant tkr1. tkr1 harbors a point mutation in GORK, which encodes gated outwardly rectifying K(+)channel proteins. This mutation alleviated TK VI-induced suppression of K(+)efflux in roots, thereby stabilizing the auxin gradient. The tkr1 mutant also resisted the phytotoxicity of alamethicin. Our results indicate that GORK channels play a key role in peptaibol-plant interaction and that there is an inter-relationship between GORK channels and maintenance of auxin homeostasis. The cellular and molecular insight into the peptaibol-induced inhibition of plant root growth advances our understanding of Trichoderma-plant interactions. © The Author 2016. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  18. Patient-based outcome analysis is important to determine the success of total knee arthroplasty: result of a focus group discussion.

    PubMed

    Zacharia, Balaji; Paul, Manu; Thanveeruddin Sherule, Mohammed

    2016-01-01

    Total knee replacement (TKR) results in an excellent outcome in terms of pain relief. The reporting of outcomes was traditionally focused on implant survivorship and objective outcomes such as range of motion, knee stability, and radiographic alignment. However, patients and doctors had differing perceptions of all domains of outcome, especially subjective quality of life domains such as emotions and social functioning. In this study, we tried to find out the expectations of Indian patients regarding TKR and assess the level of satisfaction among our patients from their view point using focus group discussion (FGD), and whether these expectations have an impact on outcomes and patient satisfaction. This study was conducted in the Department of Orthopedics, Government Medical College, Kozhikode, Kerala, India, in November 2014. Patients between the ages 60 and 65 years who met inclusion criteria were selected. A total of 50 patients were selected for FGDs. Among them, 42 patients participated in FGD. The remaining eight did not appear for the discussion. A total of four FGD sessions were conducted. It was found that there is a discrepancy between the satisfaction levels of patient and surgeon. There is a difference in satisfaction level achieved depending on socioeconomic, geographic, and cultural characteristics. Newer methods of TKR outcome assessment combining radiological outcome, surgeon-based assessment, and patient satisfaction based on their socioeconomic status and cultural characteristics should be developed for different populations.

  19. The economics of using prophylactic antibiotic-loaded bone cement in total knee replacement.

    PubMed

    Gutowski, C J; Zmistowski, B M; Clyde, C T; Parvizi, J

    2014-01-01

    The rate of peri-prosthetic infection following total joint replacement continues to rise, and attempts to curb this trend have included the use of antibiotic-loaded bone cement at the time of primary surgery. We have investigated the clinical- and cost-effectiveness of the use of antibiotic-loaded cement for primary total knee replacement (TKR) by comparing the rate of infection in 3048 TKRs performed without loaded cement over a three-year period versus the incidence of infection after 4830 TKRs performed with tobramycin-loaded cement over a later period of time of a similar duration. In order to adjust for confounding factors, the rate of infection in 3347 and 4702 uncemented total hip replacements (THR) performed during the same time periods, respectively, was also examined. There were no significant differences in the characteristics of the patients in the different cohorts. The absolute rate of infection increased when antibiotic-loaded cement was used in TKR. However, this rate of increase was less than the rate of increase in infection following uncemented THR during the same period. If the rise in the rate of infection observed in THR were extrapolated to the TKR cohort, 18 additional cases of infection would have been expected to occur in the cohort receiving antibiotic-loaded cement, compared with the number observed. Depending on the type of antibiotic-loaded cement that is used, its cost in all primary TKRs ranges between USD $2112.72 and USD $112 606.67 per case of infection that is prevented.

  20. Much ado about nothing: the effect of tourniquet time on an accelerated rehabilitation programme following total knee replacement (TKR).

    PubMed

    Wynell-Mayow, William; Saeed, Muhammad Zahid

    2018-03-14

    The WHO includes osteoarthritis as a disease of priority, owing to its significant impact on quality of life, and globally increasing prevalence. Hospital budgets are under pressure to ration knee replacements and shorten inpatient stays. Prolonged tourniquet application has been hypothesised to extend recovery through pain and reduced mobility. A total of 123 elective total knee replacements meeting inclusion criteria took place from July 2015 to October 2017 at the Royal Free Hospital. Cases were standardised by method of TKR, implant, physiotherapy and analgesic regime according to the trust Enhanced Recovery after Surgery pathway. Tourniquet time was compared to length-of-stay post-operatively and total opioid analgesia requirement over 24 h. Median tourniquet time overall was 74 min and was decreased year-on-year from 108 to 60 min (p = 0.000). Inpatient median length-of-stay was 5 days and did not decrease (p = 0.667). Increased tourniquet time was not associated with longer length-of-stay but in fact shorter (p = 0.03199), likely due to this confounding temporal trend. Increased tourniquet time was not associated with increased opioid requirement (p = 0.78591). No association was found between tourniquet time and other complications including DVT and infection. Our study finds no evidence that reductions in tourniquet time in TKR improve recovery including length-of-stay or opioid requirement. This clinical data is expected to augment PROMs collected by the National Joint Registry.

  1. Variability in Conversation Management: Fragmentation of Discourse and Back-Channel Expressions in Japanese and English.

    ERIC Educational Resources Information Center

    Maynard, Senko K.

    The casual conversation of six pairs of Japanese and six pairs of American colleges students was analyzed for evidence of two related aspects of conversation management: the linguistic characteristics of utterance units and back-channel strategies. Utterance units are defined as those occurring between identifiable pauses or breaks in tempo.…

  2. Phonetic convergence in spontaneous conversations as a function of interlocutor language distance

    PubMed Central

    Kim, Midam; Horton, William S.; Bradlow, Ann R.

    2013-01-01

    This study explores phonetic convergence during conversations between pairs of talkers with varying language distance. Specifically, we examined conversations within two native English talkers and within two native Korean talkers who had either the same or different regional dialects, and between native and nonnative talkers of English. To measure phonetic convergence, an independent group of listeners judged the similarity of utterance samples from each talker through an XAB perception test, in which X was a sample of one talker’s speech and A and B were samples from the other talker at either early or late portions of the conversation. The results showed greater convergence for same-dialect pairs than for either the different-dialect pairs or the different-L1 pairs. These results generally support the hypothesis that there is a relationship between phonetic convergence and interlocutor language distance. We interpret this pattern as suggesting that phonetic convergence between talker pairs that vary in the degree of their initial language alignment may be dynamically mediated by two parallel mechanisms: the need for intelligibility and the extra demands of nonnative speech production and perception. PMID:23637712

  3. Timing of gazes in child dialogues: a time-course analysis of requests and back channelling in referential communication.

    PubMed

    Sandgren, Olof; Andersson, Richard; van de Weijer, Joost; Hansson, Kristina; Sahlén, Birgitta

    2012-01-01

    This study investigates gaze behaviour in child dialogues. In earlier studies the authors have investigated the use of requests for clarification and responses in order to study the co-creation of understanding in a referential communication task. By adding eye tracking, this line of research is now expanded to include non-verbal contributions in conversation. To investigate the timing of gazes in face-to-face interaction and to relate the gaze behaviour to the use of requests for clarification. Eight conversational pairs of typically developing 10-15 year olds participated. The pairs (director and executor) performed a referential communication task requiring the description of faces. During the dialogues both participants wore head-mounted eye trackers. All gazes were recorded and categorized according to the area fixated (Task, Face, Off). The verbal context for all instances of gaze at the partner's face was identified and categorized using time-course analysis. The results showed that the executor spends almost 90% of the time fixating the gaze on the task, 10% on the director's face and less than 0.5% elsewhere. Turn shift, primarily requests for clarification, and back channelling significantly predicted the executors' gaze to the face of the task director. The distribution of types of requests showed that requests for previously unmentioned information were significantly more likely to be associated with gaze at the director. The study shows that the executors' gaze at the director accompanies important dynamic shifts in the dialogue. The association with requests for clarification indicates that gaze at the director can be used to monitor the response with two modalities. Furthermore, the significantly higher association with requests for previously unmentioned information indicates that gaze may be used to emphasize the verbal content. The results will be used as a reference for studies of gaze behaviour in clinical populations with hearing and language impairments. © 2012 Royal College of Speech and Language Therapists.

  4. The role of hinges in primary total knee replacement.

    PubMed

    Gehrke, T; Kendoff, D; Haasper, C

    2014-11-01

    The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (>20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. ©2014 The British Editorial Society of Bone & Joint Surgery.

  5. Tell Me Everything You Discussed: Children's Memory for Dyadic Conversations after a 1-Week or a 3-Week Delay.

    PubMed

    Lawson, Monica; London, Kamala

    2015-08-01

    In child abuse investigations, children are often asked to recount previous conversations related to the allegations (i.e., "conversational testimony"). To explore children's ability to provide conversational testimony, we staged a semi-structured novel dyadic conversation between an adult researcher and 8-year-old children (n = 90). Children's gist recall and recognition memory for their own statements, their conversational partner's statements, and question-answer pairs were tested after either a 1-week or a 3-week delay. The results revealed that children recounted a minority of the conversation, although children recalled more after a short delay (7%) than after a long delay (4%). A majority of children's free recall statements were accurate (68%); however, approximately one-third of their free recall statements were incorrect. Children almost exclusively recounted their own statements, and rarely recalled any of the adult's statements or the question-answer pairs during free recall. Reports of the adult's statements and question-answer pairs increased with cued recall questioning, but remained minimal. During recognition testing, children were able to distinguish between true and false recognition items for their own statements and the adult's statements, but performed at chance level on recognition items concerning question-answer pairs. Forensic implications of the results are discussed. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Smoking and primary total hip or knee replacement due to osteoarthritis in 54,288 elderly men and women.

    PubMed

    Mnatzaganian, George; Ryan, Philip; Reid, Christopher M; Davidson, David C; Hiller, Janet E

    2013-09-05

    The reported association of smoking with risk of undergoing a total joint replacement (TJR) due to osteoarthritis (OA) is not consistent. We evaluated the independent association between smoking and primary TJR in a large cohort. The electronic records of 54,288 men and women, who were initially recruited for the Second Australian National Blood Pressure study, were linked to the Australian Orthopaedic Association National Joint Replacement Registry to detect total hip replacement (THR) or total knee replacement (TKR) due to osteoarthritis. Competing risk regressions that accounted for the competing risk of death estimated the subhazard ratios for TJR. One-way and probabilistic sensitivity analyses were undertaken to represent uncertainty in the classification of smoking exposure and socioeconomic disadvantage scores. An independent inverse association was found between smoking and risk of THR and TKR observed in both men and women. Compared to non-smokers, male and female smokers were respectively 40% and 30% less likely to undergo a TJR. This significant association persisted after controlling for age, co-morbidities, body mass index (BMI), physical exercise, and socioeconomic disadvantage. The overweight and obese were significantly more likely to undergo TJR compared to those with normal weight. A dose-response relationship between BMI and TJR was observed (P < 0.001). Socioeconomic status was not independently associated with risk of either THR or TKR. The strengths of the inverse association between smoking and TJR, the temporal relationship of the association, together with the consistency in the findings warrant further investigation about the role of smoking in the pathogenesis of osteoarthritis causing TJR.

  7. Does a thrombin-based topical haemostatic agent reduce blood loss and transfusion requirements after total knee revision surgery? A randomized, controlled trial.

    PubMed

    Romanò, Carlo L; Monti, Lorenzo; Logoluso, Nicola; Romanò, Delia; Drago, Lorenzo

    2015-11-01

    The aim of the present study was to assess the efficacy of a thrombin-based topical haemostatic in reducing blood requirements after total knee replacement (TKR) revision surgery. This prospective, randomized, controlled study was designed to evaluate the haemostatic efficacy and safety of a thrombin-based topical haemostatic (Floseal) versus standard treatment in patients receiving total knee revision arthroplasty. The decrease in haemoglobin values postsurgery and the blood units transfused were recorded. The decision to transfuse was made by a surgeon blinded to the patient's group allocation. Forty-eight patients were enroled in the study; twenty-four patients each were randomized to the treatment and control groups, respectively. The median decrease in haemoglobin concentration on the first postoperative day was 2.2 g/dL in the treatment group and 2.7 g/dL in the control group. A significant reduction in units of blood transfused was also observed in the treatment group compared with the control group [1.1 ± 1.13 (range 0-4) vs. 1.9 ± 1.41 (range 0-5) blood units; P = 0.04]. No major treatment-related adverse events were recorded in the study. This study shows that a thrombin-based topical haemostatic reduces the need for blood transfusion in TKR revision surgery. A thrombin-based topical haemostatic agent can be an appropriate solution to enhance haemostasis and vessel sealing at the operative site in TKR revision surgery, in order to reduce the need for blood transfusion after surgery. II.

  8. Is long-term physical activity safe for older adults with knee pain?: a systematic review.

    PubMed

    Quicke, J G; Foster, N E; Thomas, M J; Holden, M A

    2015-09-01

    To determine whether long-term physical activity is safe for older adults with knee pain. A comprehensive systematic review and narrative synthesis of existing literature was conducted using multiple electronic databases from inception until May 2013. Two reviewers independently screened, checked data extraction and carried out quality assessment. Inclusion criteria for study designs were randomised controlled trials (RCTs), prospective cohort studies or case control studies, which included adults of mean age over 45 years old with knee pain or osteoarthritis (OA), undertaking physical activity over at least 3 months and which measured a safety related outcome (adverse events, pain, physical functioning, structural OA imaging progression or progression to total knee replacement (TKR)). Of the 8614 unique references identified, 49 studies were included in the review, comprising 48 RCTs and one case control study. RCTs varied in quality and included an array of low impact therapeutic exercise interventions of varying cardiovascular intensity. There was no evidence of serious adverse events, increases in pain, decreases in physical function, progression of structural OA on imaging or increased TKR at group level. The case control study concluded that increasing levels of regular physical activity was associated with lower risk of progression to TKR. Long-term therapeutic exercise lasting 3 to 30 months is safe for most older adults with knee pain. This evidence supports current clinical guideline recommendations. However, most studies investigated selected, consenting older adults carrying out low impact therapeutic exercise which may affect result generalizability. PROSPERO 2014:CRD42014006913. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Total Knee Replacement and the Effect of Technology on Cocreation for Improved Outcomes and Delivery: Qualitative Multi-Stakeholder Study

    PubMed Central

    van Kasteren, Yasmin; Freyne, Jill

    2018-01-01

    Background The growth in patient-centered care delivery combined with the rising costs of health care have perhaps not unsurprisingly been matched by a proliferation of patient-centered technology. This paper takes a multistakeholder approach to explore how digital technology can support the cocreation of value between patients and their care teams in the delivery of total knee replacement (TKR) surgery, an increasingly common procedure to return mobility and relieve pain for people suffering from osteoarthritis. Objective The aim of this study was to investigate communications and interactions between patients and care teams in the delivery of TKR to identify opportunities for digital technology to add value to TKR health care service by enhancing the cocreation of value. Methods A multistakeholder qualitative study of user needs was conducted with Australian stakeholders (N=34): surgeons (n=12), physiotherapists (n=3), patients (n=11), and general practitioners (n=8). Data from focus groups and interviews were recorded, transcribed, and analyzed using thematic analysis. Results Encounters between patients and their care teams are information-rich but time-poor. Results showed seven different stages of the TKR journey that starts with referral to a surgeon and ends with a postoperative review at 12 months. Each stage of the journey has different information and communication challenges that can be enhanced by digital technology. Opportunities for digital technology include improved waiting list management, supporting and reinforcing patient retention and recall of information, motivating and supporting rehabilitation, improving patient preparation for hospital stay, and reducing risks and anxiety associated with postoperative wound care. Conclusions Digital technology can add value to patients’ care team communications by enhancing information flow, assisting patient recall and retention of information, improving accessibility and portability of information, tailoring information to individual needs, and by providing patients with tools to engage in their own health care management. For care teams, digital technology can add value through early detection of postoperative complications, proactive surveillance of health data for postoperative patients and patients on waiting lists, higher compliance with rehabilitation programs, and reduced length of stay. Digital technology has the potential to improve patient satisfaction and outcomes, as well as potentially reduce hospital length of stay and the burden of disease associated with postoperative morbidity. PMID:29559424

  10. Clinical Evaluation of Efficacy and Performance of All-Poly Tibial Freedom® Total Knee System for Treating Osteoarthritis Patients: Three-Year Follow Up Study.

    PubMed

    Singh, Avatar; Singh, Kanwar Kulwinder

    2017-09-01

    Advancement in technology in terms of design and building materials has made Total Knee Replacement (TKR) a highly effective, safe, and predictable orthopedic procedure. To review the clinical outcomes for efficacy and performance of Freedom Total Knee System for the management of Osteoarthritis (OA), at a minimum of three years follow up. For this retrospective, post-marketing study, clinical data of patients treated with Freedom Total Knee System was retrieved from the clinical records after approval from the Institutional Ethics Committee . All the patients above the age of 18 years who completed at least three years after TKR were observed for the study purpose. Patients treated for OA were included while the patients who received the implant for treatment of rheumatoid arthritis and traumatic injury were excluded. Factors such as aseptic loosening, implant failure, and need for revision surgery were observed to evaluate implant performance. Cases were recruited for clinical assessment of primary efficacy endpoint in terms of post-surgery maximun range of motion. Secondary efficacy endpoint was to determine the clinical and social quality of life as per the American Knee Society Score (AKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and stiffness scores. A total of 158 patients who had 191 TKR were observed for performance. The mean age of the patients was 67.67 years; mean BMI was 28.97±3.33, and the group comprised of 43% men and 57% women. Telephonic follow up at three years of 158 patients identified that none of them required revision surgery or had aseptic loosening suggesting excellent performance. Final clinical follow up at three years was available for only 35 patients (41 knee implants). The range of motion significantly improved from preoperative 104°±5.67° (range, 85°-119°) to 119.8°±11.05° (98°-123°) at follow-up (p<0.05). There was a significant improvement in clinical and functional AKSS score and WOMAC score at follow-up. The evaluation of Freedom Total Knee System for TKR in treating OA, at a minimum of three years follow up showed excellent outcomes in terms of performance, range of motion, reduced postoperative stiffness and pain, and improved functionality.

  11. Clinical Evaluation of Efficacy and Performance of All-Poly Tibial Freedom® Total Knee System for Treating Osteoarthritis Patients: Three-Year Follow Up Study

    PubMed Central

    Singh, Kanwar Kulwinder

    2017-01-01

    Introduction Advancement in technology in terms of design and building materials has made Total Knee Replacement (TKR) a highly effective, safe, and predictable orthopedic procedure. Aim To review the clinical outcomes for efficacy and performance of Freedom Total Knee System for the management of Osteoarthritis (OA), at a minimum of three years follow up. Materials and Methods For this retrospective, post-marketing study, clinical data of patients treated with Freedom Total Knee System was retrieved from the clinical records after approval from the Institutional Ethics Committee . All the patients above the age of 18 years who completed at least three years after TKR were observed for the study purpose. Patients treated for OA were included while the patients who received the implant for treatment of rheumatoid arthritis and traumatic injury were excluded. Factors such as aseptic loosening, implant failure, and need for revision surgery were observed to evaluate implant performance. Cases were recruited for clinical assessment of primary efficacy endpoint in terms of post-surgery maximun range of motion. Secondary efficacy endpoint was to determine the clinical and social quality of life as per the American Knee Society Score (AKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and stiffness scores. Results A total of 158 patients who had 191 TKR were observed for performance. The mean age of the patients was 67.67 years; mean BMI was 28.97±3.33, and the group comprised of 43% men and 57% women. Telephonic follow up at three years of 158 patients identified that none of them required revision surgery or had aseptic loosening suggesting excellent performance. Final clinical follow up at three years was available for only 35 patients (41 knee implants). The range of motion significantly improved from preoperative 104°±5.67° (range, 85°-119°) to 119.8°±11.05° (98°-123°) at follow-up (p<0.05). There was a significant improvement in clinical and functional AKSS score and WOMAC score at follow-up. Conclusion The evaluation of Freedom Total Knee System for TKR in treating OA, at a minimum of three years follow up showed excellent outcomes in terms of performance, range of motion, reduced postoperative stiffness and pain, and improved functionality. PMID:29207792

  12. Meta-analysis of epidural analgesia versus peripheral nerve blockade after total knee joint replacement.

    PubMed

    Gerrard, Adam Daniel; Brooks, Ben; Asaad, Peter; Hajibandeh, Shahab; Hajibandeh, Shahin

    2017-01-01

    Postoperative pain after major knee surgery can be severe. Our aim was to compare the outcomes of epidural analgesia and peripheral nerve blockade (PNB) in patients undergoing total knee joint replacement (TKR). Moreover, we aimed to compare outcomes of adductor canal block (ACB) with those of femoral nerve block (FNB) after TKR. We conducted a systematic search of electronic information sources, including MEDLINE; EMBASE; CINAHL; and the Cochrane Central Register of Controlled Trials (CENTRAL). We applied a combination of free text and controlled vocabulary search adapted to thesaurus headings, search operators, and limits in each of the above databases. Pain intensity assessed on visual analogue scale (VAS), nausea and vomiting, systolic hypotension, and urinary retention was the reported outcome parameters. We identified 12 randomised controlled trials (RCTs) comparing outcomes of epidural analgesia and PNB reporting a total of 670 patients. There was no significant difference between two groups in VAS scores at 0-12 h (MD -0.48; 95 % CI -1.07-0.11, P = 0.11), 12-24 h (MD 0.04; 95 % CI -0.81-0.88, P = 0.93), and 24-48 h (MD 0.16; 95 % CI -0.08-0.40, P = 0.19). However, epidural analgesia was associated with significantly higher risk of postoperative nausea and vomiting (RR 1.65; 95 % CI, 1.20-2.28, P = 0.002), hypotension (RR 1.76; 95 % CI, 1.26-2.45, P = 0.0009), and urinary retention (RR 4.51; 95 % CI, 2.27-8.96, P < 0.0001) compared to PNB. Moreover, pooled analysis of data from 6 RCTs demonstrated no significant difference in VAS score between ACB and FNB at 24 h (MD -0.00; 95 % CI, -0.56-0.56, P = 0.99) and 48 h (MD -0.06; 95 % CI, -0.14-0.03, P = 0.23). PNB is as effective as epidural analgesia for postoperative pain management in patients undergoing TKR. Moreover, it is associated with significantly lower postoperative complications. ACB appears to be an effective PNB with similar analgesic effect to FNB after TKR. Future RCTs may provide better evidence regarding knee range of motion, length of hospital stay, and neurological complications.

  13. Geographic region, socioeconomic position and the utilisation of primary total joint replacement for hip or knee osteoarthritis across western Victoria: a cross-sectional multilevel study of the Australian Orthopaedic Association National Joint Replacement Registry.

    PubMed

    Brennan-Olsen, Sharon; Vogrin, Sara; Holloway, Kara L; Page, Richard S; Sajjad, Muhammad A; Kotowicz, Mark A; Livingston, Patricia M; Khasraw, Mustafa; Hakkennes, Sharon; Dunning, Trish L; Brumby, Susan; Pedler, Daryl; Sutherland, Alasdair; Venkatesh, Svetha; Williams, Lana J; Duque, Gustavo; Pasco, Julie A

    2017-11-06

    Compared to urban residents, those in rural/regional areas often experience inequitable healthcare from specialist service providers. Independent of small between-area differences in utilisation, socially advantaged groups had the greatest uptake of joint replacement. These data suggest low correlation between 'need' vs. 'uptake' of surgery in rural/regional areas. Compared to urban residents, those in rural and regional areas often experience inequitable healthcare from specialist service providers, often due to geographical issues. We investigated associations between socioeconomic position (SEP), region of residence and utilisation of primary total knee replacement (TKR) and/or total hip replacement (THR) for osteoarthritis. As part of the Ageing, Chronic Disease and Injury study, we extracted data from the Australian Orthopaedic Association National Joint Replacement Registry (2011-2013) for adults that utilised primary TKR (n = 4179; 56% female) and/or THR (n = 3120; 54% female). Residential addresses were matched with the Australian Bureau of Statistics (ABS) 2011 census data: region of residence was defined according to local government areas (LGAs), and area-level SEP (quintiles) defined using an ABS-derived composite index. The ABS-determined control population (n = 591,265; 51% female) excluded individuals identified as cases. We performed multilevel logistic regression modelling using a stratified two-stage cluster design. TKR was higher for those aged 70-79 years (AOR 1.4 95%CI 1.3-1.5; referent = 60-69 years) and in the most advantaged SEP quintile (AOR 2.1, 95%CI 1.8-2.3; referent = SEP quintile 3); results were similar for THR (70-79 years = AOR 1.7, 95%CI 1.5-1.8; SEP quintile 5 = AOR 2.5, 95%CI 2.2-2.8). Total variances contributed by the variance in LGAs were 2% (SD random effects ± 0.28) and 3% (SD ± 0.32), respectively. Independent of small between-LGA differences in utilisation, and in contrast to the expected greater prevalence of osteoarthritis in disadvantaged populations, we report greater TKR and THR in more advantaged groups. Further research should investigate whether more advantaged populations may be over-serviced.

  14. CsI Calorimeter for a Compton-Pair Telescope

    NASA Astrophysics Data System (ADS)

    Grove, Eric J.

    We propose to build and test a hodoscopic CsI(Tl) scintillating-crystal calorimeter for a medium-energy γ-ray Compton and pair telescope. The design and technical approach for this calorimeter relies deeply on heritage from the Fermi LAT CsI Calorimeter, but it dramatically improves the low-energy performance of that design by reading out the scintillation light with silicon photomultipliers (SiPMs), making the technology developed for Fermi applicable in the Compton regime. While such a hodoscopic calorimeter is useful for an entire class of medium-energy γ-ray telescope designs, we propose to build it explicitly to support beam tests and balloon flight of the Proto-ComPair telescope, the development and construction of which was funded in a four-year APRA program beginning in 2015 ("ComPair: Steps to a Medium Energy γ-ray Mission" with PI J. McEnery of GSFC). That award did not include funding for its CsI calorimeter subsystem, and this proposal is intended to cover that gap. ComPair is a MIDEX-class instrument concept to perform a high-sensitivity survey of the γ-ray sky from 0.5 MeV to 500 MeV. ComPair is designed to provide a dramatic increase in sensitivity relative to previous instruments in this energy range (predominantly INTEGRAL/SPI and Compton COMPTEL), with the same transformative sensitivity increase - and corresponding scientific return- that the Fermi Large Area Telescope provided relative to Compton EGRET. To enable transformative science over a broad range of MeV energies and with a wide field of view, ComPair is a combined Compton telescope and pair telescope employing a silicon-strip tracker (for Compton scattering and pair conversion and tracking) and a solid-state CdZnTe calorimeter (for Compton absorption) and CsI calorimeter (for pair calorimetry), surrounded by a plastic scintillator anti-coincidence detector. Under the current proposal, we will complete the detailed design, assembly, and test of the CsI calorimeter for the risk-reduction prototype telescope, Proto-ComPair. We will: 1. Purchase CsI(Tl) crystals, Silicon Photomultipliers (SiPMs), and components for the analog and digital readout of the SiPMs; 2. Assemble and test Crystal Detector Elements (CDEs) from crystals, SiPMs and optical wrap; 3. Assemble and test analog and digital front-end and readout control boards; 4. Fabricate the mechanical structure that supports and contains the CDEs and electronics boards; and 5. Assemble and test the CsI calorimeter, and integrate it with the remainder of the Proto-ComPair subsystems. The PI team for this proposal conceived, designed, developed, assembled, tested, and currently operates the LAT calorimeter and is uniquely qualified to leverage the experience gained from that effort for ComPair.

  15. Intelligent error correction method applied on an active pixel sensor based star tracker

    NASA Astrophysics Data System (ADS)

    Schmidt, Uwe

    2005-10-01

    Star trackers are opto-electronic sensors used on-board of satellites for the autonomous inertial attitude determination. During the last years star trackers became more and more important in the field of the attitude and orbit control system (AOCS) sensors. High performance star trackers are based up today on charge coupled device (CCD) optical camera heads. The active pixel sensor (APS) technology, introduced in the early 90-ties, allows now the beneficial replacement of CCD detectors by APS detectors with respect to performance, reliability, power, mass and cost. The company's heritage in star tracker design started in the early 80-ties with the launch of the worldwide first fully autonomous star tracker system ASTRO1 to the Russian MIR space station. Jena-Optronik recently developed an active pixel sensor based autonomous star tracker "ASTRO APS" as successor of the CCD based star tracker product series ASTRO1, ASTRO5, ASTRO10 and ASTRO15. Key features of the APS detector technology are, a true xy-address random access, the multiple windowing read out and the on-chip signal processing including the analogue to digital conversion. These features can be used for robust star tracking at high slew rates and under worse conditions like stray light and solar flare induced single event upsets. A special algorithm have been developed to manage the typical APS detector error contributors like fixed pattern noise (FPN), dark signal non-uniformity (DSNU) and white spots. The algorithm works fully autonomous and adapts to e.g. increasing DSNU and up-coming white spots automatically without ground maintenance or re-calibration. In contrast to conventional correction methods the described algorithm does not need calibration data memory like full image sized calibration data sets. The application of the presented algorithm managing the typical APS detector error contributors is a key element for the design of star trackers for long term satellite applications like geostationary telecom platforms.

  16. Progress status for the Mu2e calorimeter system

    DOE PAGES

    Pezzullo, Gianantonio; Budagov, J.; Carosi, R.; ...

    2015-02-13

    The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerfulmore » $$\\mu/e$$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $$BaF_2$$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this study, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.« less

  17. Study of a stereo electro-optical tracker system for the measurement of model deformations at the national transonic facility

    NASA Technical Reports Server (NTRS)

    Hertel, R. J.

    1979-01-01

    An electro-optical method to measure the aeroelastic deformations of wind tunnel models is examined. The multitarget tracking performance of one of the two electronic cameras comprising the stereo pair is modeled and measured. The properties of the targets at the model, the camera optics, target illumination, number of targets, acquisition time, target velocities, and tracker performance are considered. The electronic camera system is shown to be capable of locating, measuring, and following the positions of 5 to 50 targets attached to the model at measuring rates up to 5000 targets per second.

  18. Reliability and validity of ten consumer activity trackers.

    PubMed

    Kooiman, Thea J M; Dontje, Manon L; Sprenger, Siska R; Krijnen, Wim P; van der Schans, Cees P; de Groot, Martijn

    2015-01-01

    Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions. Healthy adult volunteers (n = 33) walked twice on a treadmill (4.8 km/h) for 30 min while wearing ten different activity trackers (i.e. Lumoback, Fitbit Flex, Jawbone Up, Nike+ Fuelband SE, Misfit Shine, Withings Pulse, Fitbit Zip, Omron HJ-203, Yamax Digiwalker SW-200 and Moves mobile application). In free-living conditions, 56 volunteers wore the same activity trackers for one working day. Test-retest reliability was analyzed with the Intraclass Correlation Coefficient (ICC). Validity was evaluated by comparing each tracker with the gold standard (Optogait system for laboratory and ActivPAL for free-living conditions), using paired samples t-tests, mean absolute percentage errors, correlations and Bland-Altman plots. Test-retest analysis revealed high reliability for most trackers except for the Omron (ICC .14), Moves app (ICC .37) and Nike+ Fuelband (ICC .53). The mean absolute percentage errors of the trackers in laboratory and free-living conditions respectively, were: Lumoback (-0.2, -0.4), Fibit Flex (-5.7, 3.7), Jawbone Up (-1.0, 1.4), Nike+ Fuelband (-18, -24), Misfit Shine (0.2, 1.1), Withings Pulse (-0.5, -7.9), Fitbit Zip (-0.3, 1.2), Omron (2.5, -0.4), Digiwalker (-1.2, -5.9), and Moves app (9.6, -37.6). Bland-Altman plots demonstrated that the limits of agreement varied from 46 steps (Fitbit Zip) to 2422 steps (Nike+ Fuelband) in the laboratory condition, and 866 steps (Fitbit Zip) to 5150 steps (Moves app) in the free-living condition. The reliability and validity of most trackers for measuring step count is good. The Fitbit Zip is the most valid whereas the reliability and validity of the Nike+ Fuelband is low.

  19. Patient-specific instrumentation for total knee arthroplasty.

    PubMed

    Nabavi, Arash; Olwill, Caroline M; Do, Mike; Wanasawage, Tanya; Harris, Ian A

    2017-01-01

    To assess the accuracy of total knee replacements (TKRs) performed using CT-based patient-specific instrumentation by postoperative CT scan. Approval from the Ethics Committee was granted prior to commencement of this study. Fifty prospective and consecutive patients who had undergone TKR (Evolis, Medacta International) using CT-based patient-specific instrumentation (MY KNEE, Medacta International) were assessed postoperatively using a CT scan and the validated Perth protocol measurement technique. The hip-knee-ankle (HKA) angle of the lower limb in the coronal plane; the coronal, sagittal, and rotational orientation of the femoral component; and the coronal and sagittal orientation of the tibial component were measured. These results were then compared to each patient's preoperative planning. The percentage of patients found to be less than or equal to 3° of planned alignment was calculated. One patient was excluded as the femoral cutting block did not fit the femur as predicted by planning and therefore underwent a conventional TKR. Ninety-eight percent of patients were within 3° of planned alignment in the coronal plane reproducing the predicted HKA angle. Predicted coronal plane orientation of the tibial and femoral component was achieved in 100% and 96% of patients, respectively. The sagittal orientation of the femoral component was within 3° in 98% of patients. The planned sagittal positioning of the tibial component was achieved in 92% of patients. Furthermore, 90% of patients were found to have a femoral rotation within 3° of planning. Eighty-six percent of patients achieved good-to-excellent outcome at 12 months (Oxford Knee Score > 34). We have found that TKR using this patient-specific instrumentation accurately reproduces preoperative planning in all six of the parameters measured in this study.

  20. Variations in Hip Shape Are Associated with Radiographic Knee Osteoarthritis: Cross-sectional and Longitudinal Analyses of the Johnston County Osteoarthritis Project.

    PubMed

    Nelson, Amanda E; Golightly, Yvonne M; Renner, Jordan B; Schwartz, Todd A; Liu, Felix; Lynch, John A; Gregory, Jenny S; Aspden, Richard M; Lane, Nancy E; Jordan, Joanne M

    2016-02-01

    Hip shape by statistical shape modeling (SSM) is associated with hip radiographic osteoarthritis (rOA). We examined associations between hip shape and knee rOA given the biomechanical interrelationships between these joints. Bilateral baseline hip shape assessments [for those with at least 1 hip with a Kellgren-Lawrence arthritis grading scale (KL) 0 or 1] from the Johnston County Osteoarthritis Project were available. Proximal femur shape was defined on baseline pelvis radiographs and evaluated by SSM, producing mean shape and continuous variables representing independent modes of variation (14 modes = 95% of shape variance). Outcomes included prevalent [baseline KL ≥ 2 or total knee replacement (TKR)], incident (baseline KL 0/1 with followup ≥ 2), and progressive knee rOA (KL increase of ≥ 1 or TKR). Limb-based logistic regression models for ipsilateral and contralateral comparisons were adjusted for age, sex, race, body mass index (BMI), and hip rOA, accounting for intraperson correlations. We evaluated 681 hips and 682 knees from 342 individuals (61% women, 83% white, mean age 62 yrs, BMI 29 kg/m(2)). Ninety-nine knees (15%) had prevalent rOA (4 knees with TKR). Lower modes 2 and 3 scores were associated with ipsilateral prevalent knee rOA, and only lower mode 3 scores were associated with contralateral prevalent knee rOA. No statistically significant associations were seen for incident or progressive knee rOA. Variations in hip shape were associated with prevalent, but not incident or progressive, knee rOA in this cohort, and may reflect biomechanical differences between limbs, genetic influences, or common factors related to both hip shape and knee rOA.

  1. Osteoarthritis and other long-term health conditions in former elite cricketers.

    PubMed

    Jones, Mary E; Davies, Madeleine A M; Leyland, Kirsten M; Delmestri, Antonella; Porter, Angus; Ratcliffe, Jason; Peirce, Nick; Newton, Julia L; Arden, Nigel K

    2018-06-01

    This study aimed to describe the prevalence and risk of chronic conditions in former elite cricketers compared to a normal population, and describe wellbeing in former elite cricketers. Cross-sectional study. Former elite cricketers, recruited from the Professional Cricketers' Association, completed a self-report cross-sectional questionnaire. The English Longitudinal Study of Ageing (ELSA) served as the normal population. The prevalence of self-reported, GP-diagnosed conditions (heart problems, hypertension, stroke, diabetes, asthma, dementia, osteoarthritis (OA), total hip replacement (THR), total knee replacement (TKR), anxiety, depression) were reported for both population samples. Standardised morbidity ratios (SMRs) compared chronic conditions in sex-, age- and BMI-matched former cricketers (n=113) and normal population (n=4496). Heart problems were reported by 13.3% of former cricketers, significantly lower than the normal population, SMR 0.55 (0.33-0.91). Former cricketers reported 31.9% hypertension, 1.8% stroke, 6.2% diabetes, 15.0% asthma, and no dementia, none significantly different to the normal population. OA, THR, and TKR were reported by 51.3%, 14.7% and 10.7% of former cricketers, respectively, significantly higher than the normal population, SMRs 3.64 (2.81-4.71), 3.99 (2.21-7.20) and 3.84 (1.92-7.68). Anxiety and depression were reported by 12.4% and 8.8% of former cricketers, respectively, SMRs 3.95 (2.34-6.67) and 2.22 (1.20-4.14). 97% of former cricketers reflected they would undertake their cricket career again, 98% agreed that cricket enriched their lives. Heart problems were significantly lower, while OA, THR, TKR, anxiety, and depression were significantly higher in the former cricketers compared to the normal population (ELSA). Most former cricketers reflected positively on their career. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Effect of local anaesthetic infiltration on chronic postsurgical pain after total hip and knee replacement: the APEX randomised controlled trials

    PubMed Central

    Wylde, Vikki; Lenguerrand, Erik; Gooberman-Hill, Rachael; Beswick, Andrew D.; Marques, Elsa; Noble, Sian; Horwood, Jeremy; Pyke, Mark; Dieppe, Paul; Blom, Ashley W.

    2015-01-01

    Abstract Total hip replacement (THR) and total knee replacement (TKR) are usually effective at relieving pain; however, 7% to 23% of patients experience chronic postsurgical pain. These trials aimed to investigate the effect of local anaesthetic wound infiltration on pain severity at 12 months after primary THR or TKR for osteoarthritis. Between November 2009 and February 2012, 322 patients listed for THR and 316 listed for TKR were recruited into a single-centre double-blind randomised controlled trial. Participants were randomly assigned (1:1) to receive local anaesthetic infiltration and standard care or standard care alone. Participants and outcomes assessors were masked to group allocation. The primary outcome was pain severity on the WOMAC Pain Scale at 12 months after surgery. Analyses were conducted using intention-to-treat and per-protocol approaches. In the hip trial, patients in the intervention group had significantly less pain at 12 months postoperative than patients in the standard care group (differences in means: 4.74; 95% confidence interval [CI]: 0.95-8.54; P = 0.015), although the difference was not clinically significant. Post hoc analysis found that patients in the intervention group were more likely to have none to moderate pain than severe pain at 12 months than those in the standard care group (odds ratio: 10.19; 95% CI: 2.10-49.55; P = 0.004). In the knee trial, there was no strong evidence that the intervention influenced pain severity at 12 months postoperative (difference in means: 3.83; 95% CI: −0.83 to 8.49; P = 0.107). In conclusion, routine use of infiltration could be beneficial in improving long-term pain relief for some patients after THR. PMID:25659070

  3. Assessment of chronic post-surgical pain after knee replacement: development of a core outcome set.

    PubMed

    Wylde, V; MacKichan, F; Bruce, J; Gooberman-Hill, R

    2015-05-01

    Approximately 20% of patients experience chronic post-surgical pain (CPSP) after total knee replacement (TKR). There is scope to improve assessment of CPSP after TKR, and this study aimed to develop a core outcome set. Eighty patients and 43 clinicians were recruited into a three-round modified Delphi study. In Round 1, participants were presented with 56 pain features identified from a systematic review, structured interviews with patients and focus groups with clinicians. Participants assigned importance ratings, using a 1-9 scale, to individual pain features; those features rated as most important were retained in subsequent rounds. Consensus that a pain feature should be included in the core outcome set was defined as the feature having a rating of 7-9 by ≥70% of both panels (patients and clinicians) and 1-3 by ≤15% of both panels or rated as 7-9 by ≥90% of one panel. Round 1 was completed by 71 patients and 39 clinicians, and Round 3 by 62 patients and 33 clinicians. The final consensus was that 33 pain features were important. These were grouped into an 8-item core outcome set comprising: pain intensity, pain interference with daily living, pain and physical functioning, temporal aspects of pain, pain description, emotional aspects of pain, use of pain medication, and improvement and satisfaction with pain relief. This core outcome set serves to guide assessment of CPSP after TKR. Consistency in assessment can promote standardized reporting and facilitate comparability between studies that address a common but understudied type of CPSP. © 2014 The Authors. European Journal of Pain published by John Wiley & Sons Ltd on behalf of European Pain Federation - EFIC®.

  4. A bill to assist the Secretary of Housing and Urban Development in stabilizing the Home Equity Conversion Mortgage program.

    THOMAS, 113th Congress

    Sen. Menendez, Robert [D-NJ

    2013-03-06

    Senate - 06/18/2013 Committee on Banking, Housing, and Urban Affairs Subcommittee on Housing, Transportation, and Community Development. Hearings held. With printed Hearing: S.Hrg. 113-61. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  5. Increasing the Endurance and Payload Capacity of Unmanned Vehicles with Thin-Film Photovoltaics

    DTIC Science & Technology

    2014-06-01

    25  1.  Maximum Power Point Tracker .......................................................25  2.  DC-DC Power Conversion...An example of the amorphous silicon cell (from [28]). ...................................20  Figure 15.  The structure of a copper indium gallium ...for the final solar array with the maximum power point indicated

  6. Charge reconstruction of the DAMPE Silicon-Tungsten Tracker: A preliminary study with ion beams

    NASA Astrophysics Data System (ADS)

    Qiao, Rui; Peng, Wen-Xi; Guo, Dong-Ya; Zhao, Hao; Wang, Huan-Yu; Gong, Ke; Zhang, Fei; Wu, Xin; Azzarello, Phillip; Tykhonov, Andrii; Asfandiyarov, Ruslan; Gallo, Valentina; Ambrosi, Giovanni

    2018-04-01

    The DArk Matter Particle Explorer (DAMPE) is one of the four satellites within Strategic Pioneer Research Program in Space Science of the Chinese Academy of Science (CAS). DAMPE can detect electrons, photons in a wide energy range (5 GeV to 10 TeV) and ions up to iron (100 GeV to 100 TeV). The silicon-Tungsten Tracker (STK) is one of the four subdetectors in DAMPE, providing photon-electron conversion, track reconstruction and charge identification for ions. An ion beam test was carried out in CERN with 60 GeV/u Lead primary beams. Charge reconstruction and charge resolution of the STK detectors were investigated.

  7. High-fidelity frequency down-conversion of visible entangled photon pairs with superconducting single-photon detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikuta, Rikizo; Kato, Hiroshi; Kusaka, Yoshiaki

    We experimentally demonstrate a high-fidelity visible-to-telecommunicationwavelength conversion of a photon by using a solid-state-based difference frequency generation. In the experiment, one half of a pico-second visible entangled photon pair at 780 nm is converted to a 1522-nm photon. Using superconducting single-photon detectors with low dark count rates and small timing jitters, we observed a fidelity of 0.93±0.04 after the wavelength conversion.

  8. The Mu2e undoped CsI crystal calorimeter

    NASA Astrophysics Data System (ADS)

    Atanov, N.; Baranov, V.; Budagov, J.; Cervelli, F.; Colao, F.; Cordelli, M.; Corradi, G.; Davydov, Y. I.; Di Falco, S.; Diociaiuti, E.; Donati, S.; Donghia, R.; Echenard, B.; Giovannella, S.; Glagolev, V.; Grancagnolo, F.; Happacher, F.; Hitlin, D. G.; Martini, M.; Miscetti, S.; Miyashita, T.; Morescalchi, L.; Murat, P.; Pedreschi, E.; Pezzullo, G.; Porter, F.; Raffaelli, F.; Ricci, M.; Saputi, A.; Sarra, I.; Spinella, F.; Tassielli, G.; Tereshchenko, V.; Usubov, Z.; Zhu, R. Y.

    2018-02-01

    The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

  9. The DAMPE experiment: 2 year in orbit

    NASA Astrophysics Data System (ADS)

    Gargano, Fabio; DAMPE Collaboration

    2017-12-01

    The DArk Matter Particle Explorer (DAMPE) is a space mission within the strategic framework of the Chinese Academy of Sciences, resulting from a collaboration of Chinese, Italian, and Swiss institutions, and is a new addition to the growing number of particle detectors in space. It was successfully launched in December 2015 and has commenced nominal science operations since shortly after launch. Lending technologies from its predecessors such as AMS and Fermi-LAT, it features a powerful segmented electromagnetic calorimeter which thanks to its 31 radiation lengths enables the study of charged cosmic rays in the energy domain of up to 100 TeV and gamma rays of up to 10 TeV. The calorimeter is complemented with a silicon-tungsten tracker converter which yields a comparable angular resolution as current space-borne pair-conversion gamma-ray detectors. In addition, the detector features a top anti-coincidence shield made of segmented silicon plastic scintillators and a boron-doped plastic scintillator on the bottom of the instrument to detect delayed neutrons arising from cosmic ray protons showering in the calorimeter. An overview of the mission and a summary of the latest results in the domain of charged cosmic rays, gamma rays and heavy ions will be presented.

  10. Diverse Roads to Relapse: A Discriminative Cue Signaling Cocaine Availability Is More Effective in Renewing Cocaine Seeking in Goal Trackers Than Sign Trackers and Depends on Basal Forebrain Cholinergic Activity.

    PubMed

    Pitchers, Kyle K; Phillips, Kyra B; Jones, Jonte L; Robinson, Terry E; Sarter, Martin

    2017-07-26

    Stimuli associated with taking drugs are notorious instigators of relapse. There is, however, considerable variation in the motivational properties of such stimuli, both as a function of the individual and the nature of the stimulus. The behavior of some individuals (sign trackers, STs) is especially influenced by cues paired with reward delivery, perhaps because they are prone to process information via dopamine-dependent, cue-driven, incentive salience systems. Other individuals (goal trackers, GTs) are better able to incorporate higher-order contextual information, perhaps because of better executive/attentional control over behavior, which requires frontal cortical cholinergic activity. We hypothesized, therefore, that a cue that "sets the occasion" for drug taking (a discriminative stimulus, DS) would reinstate cocaine seeking more readily in GTs than STs and that this would require intact cholinergic neurotransmission. To test this, male STs and GTs were trained to self-administer cocaine using an intermittent access schedule with periods of cocaine availability and unavailability signaled by a DS + and a DS - , respectively. Thereafter, half of the rats received an immunotoxic lesion that destroyed 40-50% of basal forebrain cholinergic neurons and later, after extinction training, were tested for the ability of noncontingent presentations of the DS + to reinstate cocaine seeking behavior. The DS + was much more effective in reinstating cocaine seeking in GTs than STs and this effect was abolished by cholinergic losses despite the fact that all rats continued to orient to the DS + We conclude that vulnerability to relapse involves interactions between individual cognitive-motivational biases and the form of the drug cue encountered. SIGNIFICANCE STATEMENT The most predictable outcome of a diagnosis of addiction is a high chance for relapse. When addicts encounter cues previously associated with drug, their attention may be unduly attracted to such cues and these cues can evoke motivational states that instigate and maintain drug-seeking behavior. Although sign-tracking rats were previously demonstrated to exhibit greater relapse vulnerability to Pavlovian drug cues paired with drug delivery, here, we demonstrate that their counterparts, the goal trackers, are more vulnerable if the drug cue acts to signal drug availability and that the forebrain cholinergic system mediates such vulnerability. Given the importance of contextual cues for triggering relapse and the human cognitive-cholinergic capacity for the processing of such cues, goal trackers model essential aspects of relapse vulnerability. Copyright © 2017 the authors 0270-6474/17/377198-11$15.00/0.

  11. Single-photon frequency conversion via cascaded quadratic nonlinear processes

    NASA Astrophysics Data System (ADS)

    Xiang, Tong; Sun, Qi-Chao; Li, Yuanhua; Zheng, Yuanlin; Chen, Xianfeng

    2018-06-01

    Frequency conversion of single photons is an important technology for quantum interface and quantum communication networks. Here, single-photon frequency conversion in the telecommunication band is experimentally demonstrated via cascaded quadratic nonlinear processes. Using cascaded quasi-phase-matched sum and difference frequency generation in a periodically poled lithium niobate waveguide, the signal photon of a photon pair from spontaneous down-conversion is precisely shifted to identically match its counterpart, i.e., the idler photon, in frequency to manifest a clear nonclassical dip in the Hong-Ou-Mandel interference. Moreover, quantum entanglement between the photon pair is maintained after the frequency conversion, as is proved in time-energy entanglement measurement. The scheme is used to switch single photons between dense wavelength-division multiplexing channels, which holds great promise in applications in realistic quantum networks.

  12. A qualitative evaluation of breast cancer survivors' acceptance of and preferences for consumer wearable technology activity trackers.

    PubMed

    Nguyen, Nga H; Hadgraft, Nyssa T; Moore, Melissa M; Rosenberg, Dori E; Lynch, Chris; Reeves, Marina M; Lynch, Brigid M

    2017-11-01

    Physical inactivity and sedentary behaviour are common amongst breast cancer survivors. These behaviours are associated with an increased risk of comorbidities such as heart disease, diabetes and other cancers. Commercially available, wearable activity trackers (WATs) have potential utility as behavioural interventions to increase physical activity and reduce sedentary behaviour within this population. The purpose of the study is to explore the acceptability and usability of consumer WAT amongst postmenopausal breast cancer survivors. Fourteen participants tested two to three randomly assigned trackers from six available models (Fitbit One, Jawbone Up 24, Garmin Vivofit 2, Garmin Vivosmart, Garmin Vivoactive and Polar A300). Participants wore each device for 2 weeks, followed by a 1-week washout period before wearing the next device. Four focus groups employing a semi-structured interview guide explored user perceptions and experiences. We used a thematic analysis approach to analyse focus group transcripts. Five themes emerged from our data: (1) trackers' increased self-awareness and motivation, (2) breast cancer survivors' confidence and comfort with wearable technology, (3) preferred and disliked features of WAT, (4) concerns related to the disease and (5) peer support and doctor monitoring were possible strategies for WAT application. WATs are perceived as useful and acceptable interventions by postmenopausal breast cancer survivors. Effective WAT interventions may benefit from taking advantage of the simple features of the trackers paired with other behavioural change techniques, such as specialist counselling, doctor monitoring and peer support, along with simple manual instructions.

  13. Searching for displaced Higgs boson decays

    NASA Astrophysics Data System (ADS)

    Csáki, Csaba; Kuflik, Eric; Lombardo, Salvator; Slone, Oren

    2015-10-01

    We study a simplified model of the Standard Model (SM) Higgs boson decaying to a degenerate pair of scalars which travel a macroscopic distance before decaying to SM particles. This is the leading signal for many well-motivated solutions to the hierarchy problem that do not propose additional light colored particles. Bounds for displaced Higgs boson decays below 10 cm are found by recasting existing tracker searches from Run I. New tracker search strategies, sensitive to the characteristics of these models and similar decays, are proposed with sensitivities projected for Run II at √{s }=13 TeV . With 20 fb-1 of data, we find that Higgs branching ratios down to 2 ×1 0-4 can be probed for centimeter decay lengths.

  14. Mu2e, a coherent μ --> e conversion experiment at Fermilab

    NASA Astrophysics Data System (ADS)

    Brown, D. N.; Mu2e Collaboration

    2012-09-01

    We describe a proposed experiment to search for Charged Lepton Flavor Violation (CLFV) using stopped muons at Fermilab. A primary Proton beam will strike a gold target, producing pions which decay to muons. Low-momentum negative muons will be collected, selected, and transported by a custom arrangement of solenoidal magnets and collimators. Muons will stop in thin foil targets, creating muonic atoms with significant nuclear overlap. Mu2e will search for the coherent conversion of nuclear bound muons to electrons, with an experimental signature of a single mono-energetic electron. Conversion electrons will be detected and measured in a low-mass straw tracker and a crystal calorimeter. Mu2e will have a sensitivity four orders of magnitude better than the most sensitive published result for μ → e conversion, and will have complementary physics reach to LHC experiments and μ → eγ decay experiments such as MEG.

  15. Reconstruction of neutrino induced NC-1π{sup 0} using the T2K-ND280 tracker

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O’Keeffe, H. M.; Vacheret, A.; Barr, G. D.

    2015-05-15

    Single π{sup 0} production is the one of the most important backgrounds in the υ{sub e} appearance measurement in T2K. Large uncertainties in this production make it difficult to predict. Measurement at the near detector (ND280) is required both to constrain the background prediction at the far detector (Super-K) and also at the near detector to improve knowledge of beam υ{sub e} contamination. We present an analysis based on Monte Carlo simulation of neutral current (NC) single π{sup 0} in the tracker region. NC-1π{sup 0} events are selected using a specific two-gamma signature in the tracker region. One decay gammamore » is reconstructed by selecting an e+/e− pair starting in the Fine-Grained target Detector (FGD) and extending into the TPC, where the leptons can be identified and their momentum measured accurately. The second gamma is then selected in-time in the Calorimeter modules surrounding the tracker. Selections cuts, efficiency and purity of the selection are presented and projection of the expected number of single π{sup 0} candidates for 3 × 10{sup 20} protons on target (PoT) exposure is made.« less

  16. Sign Tracking, but Not Goal Tracking, is Resistant to Outcome Devaluation

    PubMed Central

    Morrison, Sara E.; Bamkole, Michael A.; Nicola, Saleem M.

    2015-01-01

    During Pavlovian conditioning, a conditioned stimulus (CS) may act as a predictor of a reward to be delivered in another location. Individuals vary widely in their propensity to engage with the CS (sign tracking) or with the site of eventual reward (goal tracking). It is often assumed that sign tracking involves the association of the CS with the motivational value of the reward, resulting in the CS acquiring incentive value independent of the outcome. However, experimental evidence for this assumption is lacking. In order to test the hypothesis that sign tracking behavior does not rely on a neural representation of the outcome, we employed a reward devaluation procedure. We trained rats on a classic Pavlovian paradigm in which a lever CS was paired with a sucrose reward, then devalued the reward by pairing sucrose with illness in the absence of the CS. We found that sign tracking behavior was enhanced, rather than diminished, following reward devaluation; thus, sign tracking is clearly independent of a representation of the outcome. In contrast, goal tracking behavior was decreased by reward devaluation. Furthermore, when we divided rats into those with high propensity to engage with the lever (sign trackers) and low propensity to engage with the lever (goal trackers), we found that nearly all of the effects of devaluation could be attributed to the goal trackers. These results show that sign tracking and goal tracking behavior may be the output of different associative structures in the brain, providing insight into the mechanisms by which reward-associated stimuli—such as drug cues—come to exert control over behavior in some individuals. PMID:26733783

  17. Examining the role of dopamine D2 and D3 receptors in Pavlovian conditioned approach behaviors.

    PubMed

    Fraser, Kurt M; Haight, Joshua L; Gardner, Eliot L; Flagel, Shelly B

    2016-05-15

    Elucidating the neurobiological mechanisms underlying individual differences in the extent to which reward cues acquire the ability to act as incentive stimuli may contribute to the development of successful treatments for addiction and related disorders. We used the sign-tracker/goal-tracker animal model to examine the role of dopamine D2 and D3 receptors in the propensity to attribute incentive salience to reward cues. Following Pavlovian training, wherein a discrete lever-cue was paired with food reward, rats were classified as sign- or goal-trackers based on the resultant conditioned response. We examined the effects of D2/D3 agonists, 7-OH-DPAT (0.01-0.32mg/kg) or pramipexole (0.032-0.32mg/kg), the D2/D3 antagonist raclopride (0.1mg/kg), and the selective D3 antagonist, SB-277011A (6 or 24mg/kg), on the expression of sign- and goal-tracking conditioned responses. The lever-cue acquired predictive value and elicited a conditioned response for sign- and goal-trackers, but only for sign-trackers did it also acquire incentive value. Following administration of either 7-OH-DPAT, pramipexole, or raclopride, the performance of the previously acquired conditioned response was attenuated for both sign- and goal-trackers. For sign-trackers, the D2/D3 agonist, 7-OH-DPAT, also attenuated the conditioned reinforcing properties of the lever-cue. The selective D3 antagonist did not affect either conditioned response. Alterations in D2/D3 receptor signaling, but not D3 signaling alone, transiently attenuate a previously acquired Pavlovian conditioned response, regardless of whether the response is a result of incentive motivational processes. These findings suggest activity at the dopamine D2 receptor is critical for a reward cue to maintain either its incentive or predictive qualities. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Examining the Role of Dopamine D2 and D3 Receptors in Pavlovian Conditioned Approach Behaviors

    PubMed Central

    Fraser, Kurt M.; Haight, Joshua L.; Gardner, Eliot L.; Flagel, Shelly B.

    2016-01-01

    Elucidating the neurobiological mechanisms underlying individual differences in the extent to which reward cues acquire the ability to act as incentive stimuli may contribute to the development of successful treatments for addiction and related disorders. We used the sign-tracker/goal-tracker animal model to examine the role of dopamine D2 and D3 receptors in the propensity to attribute incentive salience to reward cues. Following Pavlovian training, wherein a discrete lever-cue was paired with food reward, rats were classified as sign- or goal-trackers based on the resultant conditioned response. We examined the effects of D2/D3 agonists, 7-OH-DPAT (0.01–0.32 mg/kg) or pramipexole (0.032–0.32 mg/kg), the D2/D3 antagonist raclopride (0.1 mg/kg), and the selective D3 antagonist, SB-277011A (6 or 24 mg/kg), on the expression of sign- and goal-tracking conditioned responses. The lever-cue acquired predictive value and elicited a conditioned response for sign- and goal-trackers, but only for sign-trackers did it also acquire incentive value. Following administration of either 7-OH-DPAT, pramipexole, or raclopride, the performance of the previously acquired conditioned response was attenuated for both sign- and goal-trackers. For sign-trackers, the D2/D3 agonist, 7-OH-DPAT, also attenuated the conditioned reinforcing properties of the lever-cue. The selective D3 antagonist did not affect either conditioned response. Alterations in D2/D3 receptor signaling, but not D3 signaling alone, transiently attenuate a previously acquired Pavlovian conditioned response, regardless of whether the response is a result of incentive motivational processes. These findings suggest activity at the dopamine D2 receptor is critical for a reward cue to maintain either its incentive or predictive qualities. PMID:26909847

  19. Knee stabilisation following infected knee arthroplasty with bone loss and extensor mechanism impairment using a modular cemented nail.

    PubMed

    Rao, M C; Richards, O; Meyer, C; Jones, R Spencer

    2009-12-01

    Infected Total Knee Replacement with significant bone loss and loss of extensor mechanism poses a difficult management problem. Arthrodesis relying on bony union can be difficult to achieve and can result in significant limb shortening. We retrospectively looked at the outcome of seven patients with significant bone loss and extensor mechanism insufficiency following infected TKR who underwent knee stabilisation using a modular cemented nail. The nail relied on the strong coupling mechanism between the modular femoral and tibial components. Pain score improved from a mean of 7.9 pre-operatively to 1.5 post-operatively at a mean follow up of 39.6 months (range 7-68) months. Two patients underwent technically easy revision nailing for recurrent infection and aseptic loosening. The Endo-Model(R) Knee Fusion Nail (Newsplint, UK/Waldemar Link, GmbH & Co. KG, Hamburg, Germany) has good early results in terms of pain relief and provides a stable knee in cases with significant bone loss and extensor mechanism insufficiency following an infected TKR thus avoiding an above knee amputation.

  20. Highlights from PHENIX at RHIC

    NASA Astrophysics Data System (ADS)

    Nouicer, Rachid

    2018-02-01

    Hadrons conveying strange quarks or heavy quarks are essential probes of the hot and dense medium created in relativistic heavy-ion collisions. With hidden strangeness, ϕ meson production and its transport in the nuclear medium have attracted high interest since its discovery. Heavy quark-antiquark pairs, like charmonium and bottomonium mesons, are mainly produced in initial hard scattering processes of partons. While some of the produced pairs form bound quarkonia, the vast majority hadronize into particles carrying open heavy flavor. In this context, the PHENIX collaboration carries out a comprehensive physics program which studies the ϕ meson production, and heavy flavor production in relativistic heavy-ion collisions at RHIC. In recent years, the PHENIX experiment upgraded the detector in installing silicon vertex tracker (VTX) at mid-rapidity region and forward silicon vertex tracker (FVTX) at the forward rapidity region. With these new upgrades, the experiment has collected large data samples, and enhanced the capability of heavy flavor measurements via precision tracking. This paper summarizes the latest PHENIX results concerning ϕ meson, open and closed charm and beauty heavy quark production in relativistic heavy-ion collisions. These results are presented as a function of rapidity, energy and system size, and their interpretation with respect to the current theoretical understanding.

  1. Distribution of polarization-entangled photonpairs produced via spontaneous parametric down-conversion within a local-area fiber network: theoretical model and experiment.

    PubMed

    Lim, Han Chuen; Yoshizawa, Akio; Tsuchida, Hidemi; Kikuchi, Kazuro

    2008-09-15

    We present a theoretical model for the distribution of polarization-entangled photon-pairs produced via spontaneous parametric down-conversion within a local-area fiber network. This model allows an entanglement distributor who plays the role of a service provider to determine the photon-pair generation rate giving highest two-photon interference fringe visibility for any pair of users, when given user-specific parameters. Usefulness of this model is illustrated in an example and confirmed in an experiment, where polarization-entangled photon-pairs are distributed over 82 km and 132 km of dispersion-managed optical fiber. Experimentally observed visibilities and entanglement fidelities are in good agreement with theoretically predicted values.

  2. Physiotherapy rehabilitation after total knee or hip replacement: an evidence-based analysis.

    PubMed

    2005-01-01

    The objective of this health technology policy analysis was to determine, where, how, and when physiotherapy services are best delivered to optimize functional outcomes for patients after they undergo primary (first-time) total hip replacement or total knee replacement, and to determine the Ontario-specific economic impact of the best delivery strategy. The objectives of the systematic review were as follows: To determine the effectiveness of inpatient physiotherapy after discharge from an acute care hospital compared with outpatient physiotherapy delivered in either a clinic-based or home-based setting for primary total joint replacement patientsTo determine the effectiveness of outpatient physiotherapy delivered by a physiotherapist in either a clinic-based or home-based setting in addition to a home exercise program compared with a home exercise program alone for primary total joint replacement patientsTo determine the effectiveness of preoperative exercise for people who are scheduled to receive primary total knee or hip replacement surgery Total hip replacements and total knee replacements are among the most commonly performed surgical procedures in Ontario. Physiotherapy rehabilitation after first-time total hip or knee replacement surgery is accepted as the standard and essential treatment. The aim is to maximize a person's functionality and independence and minimize complications such as hip dislocation (for hip replacements), wound infection, deep vein thrombosis, and pulmonary embolism. THE THERAPY: The physiotherapy rehabilitation routine has 4 components: therapeutic exercise, transfer training, gait training, and instruction in the activities of daily living. Physiotherapy rehabilitation for people who have had total joint replacement surgery varies in where, how, and when it is delivered. In Ontario, after discharge from an acute care hospital, people who have had a primary total knee or hip replacement may receive inpatient or outpatient physiotherapy. Inpatient physiotherapy is delivered in a rehabilitation hospital or specialized hospital unit. Outpatient physiotherapy is done either in an outpatient clinic (clinic-based) or in the person's home (home-based). Home-based physiotherapy may include practising an exercise program at home with or without supplemental support from a physiotherapist. Finally, physiotherapy rehabilitation may be administered at several points after surgery, including immediately postoperatively (within the first 5 days) and in the early recovery period (within the first 3 months) after discharge. There is a growing interest in whether physiotherapy should start before surgery. A variety of practises exist, and evidence regarding the optimal pre- and post-acute course of rehabilitation to obtain the best outcomes is needed. The Medical Advisory Secretariat used its standard search strategy, which included searching the databases of Ovid MEDLINE, CINHAL, EMBASE, Cochrane Database of Systematic Reviews, and PEDro from 1995 to 2005. English-language articles including systematic reviews, randomized controlled trials (RCTs), non-RCTs, and studies with a sample size of greater than 10 patients were included. Studies had to include patients undergoing primary total hip or total knee replacement, aged 18 years of age or older, and they had to have investigated one of the following comparisons: inpatient rehabilitation versus outpatient (clinic- or home-based therapy) rehabilitation, land-based post-acute care physiotherapy delivered by a physiotherapist compared with patient self-administered exercise and a land-based exercise program before surgery. The primary outcome was postoperative physical functioning. Secondary outcomes included the patient's assessment of therapeutic effect (overall improvement), perceived pain intensity, health services utilization, treatment side effects, and adverse events The quality of the methods of the included studies was assessed using the criteria outlined in the Cochrane Musculoskeletal Injuries Group Quality Assessment Tool. After this, a summary of the biases threatening study validity was determined. Four methodological biases were considered: selection bias, performance bias, attrition bias, and detection bias. A meta-analysis was conducted when adequate data were available from 2 or more studies and where there was no statistical or clinical heterogeneity among studies. The GRADE system was used to summarize the overall quality of evidence. The search yielded 422 citations; of these, 12 were included in the review including 10 primary studies (9 RCTs, 1 non-RCT) and 2 systematic reviews. The Medical Advisory Secretariat review included 2 primary studies (N = 334) that examined the effectiveness of an inpatient physiotherapy rehabilitation program compared with an outpatient home-based physiotherapy program on functional outcomes after total knee or hip replacement surgery. One study, available only as an abstract, found no difference in functional outcome at 1 year after surgery (TKR or THR) between the treatments. The other study was an observational study that found that patients who are younger than 71 years of age on average, who do not live alone, and who do not have comorbid illnesses recover adequate function with outpatient home-based physiotherapy. However results were only measured up to 3 months after surgery, and the outcome measure they used is not considered the best one for physical functioning. Three primary studies (N = 360) were reviewed that tested the effectiveness of outpatient home-based or clinic-based physiotherapy in addition to a self-administered home exercise program, compared with a self-administered exercise program only or in addition to using another therapy (phone calls or continuous passive movement), on postoperative physical functioning after primary TKR surgery. Two of the studies reported no difference in change from baseline in flexion range of motion between those patients receiving outpatient or home-based physiotherapy and doing a home exercise program compared with patients who did a home exercise program only with or without continuous passive movement. The other study reported no difference in the Western Ontario and McMaster Osteoarthritis Index (WOMAC) scores between patients receiving clinic-based physiotherapy and practising a home exercise program and those who received monitoring phone calls and did a home exercise program after TKR surgery. The Medical Advisory Secretariat reviewed two systematic reviews evaluating the effects of preoperative exercise on postoperative physical functioning. One concluded that preoperative exercise is not effective in improving functional recovery or pain after TKR and any effects after THR could not be adequately determined. The other concluded that there was inconclusive evidence to determine the benefits of preoperative exercise on functional recovery after TKR. Because 2 primary studies were added to the published literature since the publication of these systematic reviews the Medical Advisory Secretariat revisited the question of effectiveness of a preoperative exercise program for patients scheduled for TKR ad THR surgery. The Medical Advisory Secretariat also reviewed 3 primary studies (N = 184) that tested the effectiveness of preoperative exercise beginning 4-6 weeks before surgery on postoperative outcomes after primary TKR surgery. All 3 studies reported negative findings with regard to the effectiveness of preoperative exercise to improve physical functioning after TKR surgery. However, 2 failed to show an effect of the preoperative exercise program before surgery in those patients receiving preoperative exercise. The third study did not measure functional outcome immediately before surgery in the preoperative exercise treatment group; therefore the study's authors could not document an effect of the preoperative exercise program before surgery. Regarding health services utilization, 2 of the studies did not find significant differences in either the length of the acute care hospital stay or the inpatient rehabilitation care setting between patients treated with a preoperative exercise program and those not treated. The third study did not measure health services utilization. These results must be interpreted within the limitations and the biases of each study. Negative results do not necessarily support a lack of treatment effect but may be attributed to a type II statistical error. Finally, the Medical Advisory Secretariat reviewed 2 primary studies (N = 136) that examined the effectiveness of preoperative exercise on postoperative functional outcomes after primary THR surgery. One study did not support the effectiveness of an exercise program beginning 8 weeks before surgery. However, results from the other did support the effectiveness of an exercise program 8 weeks before primary THR surgery on pain and functional outcomes 1 week before and 3 weeks after surgery. Based on the evidence, the Medical Advisory Secretariat reached the following conclusions with respect to physiotherapy rehabilitation and physical functioning 1 year after primary TKR or THR surgery: There is high-quality evidence from 1 large RCT to support the use of home-based physiotherapy instead of inpatient physiotherapy after primary THR or TKR surgery.There is low-to-moderate quality evidence from 1 large RCT to support the conclusion that receiving a monitoring phone call from a physiotherapist and practising home exercises is comparable to receiving clinic-based physiotherapy and practising home exercises for people who have had primary TKR surgery. However, results may not be generalizable to those who have had THR surgery.There is moderate evidence to suggest that an exercise program beginning 4 to 6 weeks before primary TKR surgery is not effective. (ABSTRACT TRUNCATED)

  3. A Panel Prototype for the Mu2e Straw Tube Tracker at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucà, Alessandra

    The Mu2e experiment will search for coherent, neutrino-less conversion of muons into electrons in the Coulomb field of an aluminum nucleus with a sensitivity of four orders of magnitude better than previous experiments. The signature of this process is an electron with energy nearly equal to the muon mass. Mu2e relies on a precision (0.1%) measurement of the outgoing electron momentum to separate signal from background. In order to achieve this goal, Mu2e has chosen a very low-mass straw tracker, made of 20,736 5 mm diameter thin-walled (15more » $$\\mu$$m) Mylar straws, held under tension to avoid the need for supports within the active volume, and arranged in an approximately 3 m long by 0.7 m radius cylinder, operated in vacuum and a 1 T magnetic field. Groups of 96 straws are assembled into modules, called panels. We present the prototype and the assembly procedure for a Mu2e tracker panel built at Fermilab« less

  4. The Mu2e undoped CsI crystal calorimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atanov, N.; Baranov, V.; Budagov, J.

    We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystalsmore » and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.« less

  5. The Mu2e undoped CsI crystal calorimeter

    DOE PAGES

    Atanov, N.; Baranov, V.; Budagov, J.; ...

    2018-02-22

    We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystalsmore » and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.« less

  6. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements.

    PubMed

    Abdelgaied, A; Fisher, J; Jennings, L M

    2018-02-01

    A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active patients (National_Joint_Registry, 2016). The current study has developed and validated a comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements (TKR). The input mechanical (elastic modulus and Poisson's ratio) and wear parameters of the moderately cross-linked ultra-high molecular weight polyethylene (UHMWPE) bearing material were independently measured from experimental studies under realistic test conditions, similar to the loading conditions found in the total knee replacements. The wear predictions from the computational wear simulation were validated against the direct experimental wear measurements for size 3 Sigma curved total knee replacements (DePuy, UK) in an independent experimental wear simulation study under three different daily activities; walking, deep squat, and stairs ascending kinematic conditions. The measured compressive mechanical properties of the moderately cross-linked UHMWPE material were more than 20% lower than that reported in the literature under tensile test conditions. The pin-on-plate wear coefficient of moderately cross-linked UHMWPE was significantly dependant of the contact stress and the degree of cross-shear at the articulating surfaces. The computational wear predictions for the TKR from the current framework were consistent and in a good agreement with the independent full TKR experimental wear simulation measurements, with 0.94 coefficient of determination of the framework. In addition, the comprehensive combined experimental and computational framework was able to explain the complex experimental wear trends from the three different daily activities investigated. Therefore, such a framework can be adopted as a pre-clinical simulation approach to optimise different designs, materials, as well as patient's specific total knee replacements for a range of activities. Copyright © 2017. Published by Elsevier Ltd.

  7. Predictors for moderate to severe acute postoperative pain after total hip and knee replacement.

    PubMed

    Liu, Spencer S; Buvanendran, Asokumar; Rathmell, James P; Sawhney, Mona; Bae, James J; Moric, Mario; Perros, Stephen; Pope, Ashley J; Poultsides, Lazaros; Della Valle, Craig J; Shin, Naomi S; McCartney, Colin J L; Ma, Yan; Shah, Mahendrakumar; Wood, Monica J; Manion, Smith C; Sculco, Thomas P

    2012-11-01

    The ability to identify and focus care to patients at higher risk of moderate to severe postoperative pain should improve analgesia and patient satisfaction, and may affect reimbursement. We undertook this multi-centre cross-sectional study to identify preoperative risk factors for moderate to severe pain after total hip (THR) and knee (TKR) replacement. A total of 897 patients were identified from electronic medical records. Preoperative information and anaesthetic technique was gained by retrospective chart review. The primary outcomes were moderate to severe pain (pain score ≥ 4/10) at rest and with activity on postoperative day one. Logistic regression was performed to identify predictors for moderate to severe pain. Moderate to severe pain was reported by 20 % at rest and 33 % with activity. Predictors for pain at rest were female gender (OR 1.10 with 95 % CI 1.01-1.20), younger age (0.96, 0.94-0.99), increased BMI (1.02, 1.01-1.03), TKR vs. THR (3.21, 2.73-3.78), increased severity of preoperative pain at the surgical site (1.15, 1.03-1.30), preoperative use of opioids (1.63, 1.32-2.01), and general anaesthesia (8.51, 2.13-33.98). Predictors for pain with activity were TKR vs. THR (1.42, 1.28-1.57), increased severity of preoperative pain at the surgical site (1.11, 1.04-1.19), general anaesthesia (9.02, 3.68-22.07), preoperative use of anti-convulsants (1.78, 1.32-2.40) and anti-depressants (1.50, 1.08-2.80), and prior surgery at the surgical site (1.28, 1.05-1.57). Our findings provide clinical guidance for preoperative stratification of patients for more intensive management potentially including education, nursing staffing, and referral to specialised pain management.

  8. Associations between pre-operative radiographic changes and outcomes after total knee joint replacement for osteoarthritis.

    PubMed

    Dowsey, M M; Nikpour, M; Dieppe, P; Choong, P F M

    2012-10-01

    To assess the influence of pre-operative X-ray changes on the response to total knee joint replacement (TKR). We included patients from one centre who underwent primary TKR (n = 478) for osteoarthritis in 2006 and 2007. The International Knee Society score (IKSS) and short form health survey were collected pre-operatively and at 1 and 2 years after surgery. Pre-operative radiographs were read to assess Kellgren and Lawrence (K-L) grading, individual radiographic features using the OARSI atlas, and subchondral bone attrition using the Ahlbach method. The main independent variable was a modified (K-L) grade. The outcome variables were the IKSS pain and function scores. Covariates included demographic features, co-morbidities, baseline pain and function, prosthesis type, and the use of patella resurfacing. Multivariable linear regression models were created to assess the relationships between pre-operative X-ray findings and pain and function outcomes. On average, pain and function improved greatly following surgery. However, pain relief was unsatisfactory in about 30%, and functional improvement suboptimal in about 50%. OR (95% CI) for ongoing moderate-severe pain at 12 months for modified K-L grades; <3: 5.39 (1.23-15.69), 3a: 2.62 (1.21-5.67), 3b: 1.81 (1.00-3.26), 4a: 2.06 (1.05-4.05) when compared to 4b. OR (95% CI) for poor function at 12 months were; 3a: 2.81 (1.23-6.39) and 4a: 2.45 (1.22-4.91), when compared to 4b. Patients with more severe radiographic knee damage at the time of surgery are most likely to have substantial gains in terms of both pain relief and improved function as a result of a TKR. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  9. Coherence properties of spontaneous parametric down-conversion pumped by a multi-mode cw diode laser.

    PubMed

    Kwon, Osung; Ra, Young-Sik; Kim, Yoon-Ho

    2009-07-20

    Coherence properties of the photon pair generated via spontaneous parametric down-conversion pumped by a multi-mode cw diode laser are studied with a Mach-Zehnder interferometer. Each photon of the pair enters a different input port of the interferometer and the biphoton coherence properties are studied with a two-photon detector placed at one output port. When the photon pair simultaneously enters the interferometer, periodic recurrence of the biphoton de Broglie wave packet is observed, closely resembling the coherence properties of the pump diode laser. With non-zero delays between the photons at the input ports, biphoton interference exhibits the same periodic recurrence but the wave packet shapes are shown to be dependent on both the input delay as well as the interferometer delay. These properties could be useful for building engineered entangled photon sources based on diode laser-pumped spontaneous parametric down-conversion.

  10. Developing and Evaluating Creativity Gamification Rehabilitation System: The Application of PCA-ANFIS Based Emotions Model

    ERIC Educational Resources Information Center

    Su, Chung-Ho; Cheng, Ching-Hsue

    2016-01-01

    This study aims to explore the factors in a patient's rehabilitation achievement after a total knee replacement (TKR) patient exercises, using a PCA-ANFIS emotion model-based game rehabilitation system, which combines virtual reality (VR) and motion capture technology. The researchers combine a principal component analysis (PCA) and an adaptive…

  11. Connective Choice between Native and Japanese Speakers.

    ERIC Educational Resources Information Center

    Tabuki, Masatoshi; Shimatani, Hiroshi

    A study investigated the use of connectors in English conversation between native Japanese-speakers and teachers outside the classroom. Data were drawn from six videotaped conversations between pairs of Japanese students, all learning beginning-level English, with conversational support provided by English teachers. The functions of four…

  12. A Conversation Analytic Study on Teaching Moments Observed in Free Conversations between Japanese and American Friends

    ERIC Educational Resources Information Center

    Nagai, Ayako

    2011-01-01

    Utilizing the methodology of Conversation Analysis (CA), this study examines teaching moments observed in free conversations by pairs of Japanese and American friends. CA's detailed turn-by-turn analysis reveals that teaching of vocabulary, idioms, and culture occurs when native speakers orient to the non-nativeness of the other speakers.…

  13. Socialization As and through Conversation: Political Discourse in Israeli Families.

    ERIC Educational Resources Information Center

    Ribak, Rivka

    1997-01-01

    Survey of Israeli parent-child pairs revealed portraits of moderate parents and radical children, but follow-up of family conversation while watching and discussing television news suggested harmony and unity in Israeli living rooms. Reconceptualization of the theoretical canon of political socialization analyzes the conversation as a moment of…

  14. Conversation Analysis--A Discourse Approach to Teaching Oral English Skills

    ERIC Educational Resources Information Center

    Wu, Yan

    2013-01-01

    This paper explores a pedagocial approach to teaching oral English---Conversation Analysis. First, features of spoken language is described in comparison to written language. Second, Conversation Analysis theory is elaborated in terms of adjacency pairs, turn-taking, repairs, sequences, openings and closings, and feedback. Third, under the…

  15. Analysis for Mar Vel Black and acetylene soot low reflectivity surfaces for star tracker sunshade applications

    NASA Technical Reports Server (NTRS)

    Yung, E.

    1974-01-01

    Mar Vel Black is a revolutionary new extremely low reflectivity anodized coating developed by Martin Marietta of Denver. It is of great interest in optics in general, and in star trackers specifically because it can reduce extraneous light reflections. A sample of Mar Vel Black was evaluated. Mar Vel Black looks much like a super black surface with many small peaks and very steep sides so that any light incident upon the surface will tend to reflect many times before exiting that surface. Even a high reflectivity surface would thus appear to have a very low reflectivity under such conditions. Conversely, acetylene soot does not have the magnified surface appearance of a super black surface. Its performance is, however, predictable from the surface structure, considering the known configuration of virtually pure carbon.

  16. Spectral correlation and interference in non-degenerate photon pairs at telecom wavelengths.

    PubMed

    Kuo, Paulina S; Gerrits, Thomas; Verma, Varun B; Nam, Sae Woo

    2016-11-01

    We characterize an entangled-photon-pair source that produces signal and idler photons at 1533 nm and 1567 nm using fiber-assisted signal-photon spectroscopy. By erasing the polarization distinguishability, we observe interference between the two down-conversion paths. The observed interference signature is closely related to the spectral correlations between photons in a Hong-Ou-Mandel interferometer. These measurements suggest good indistinguishability between the two down-conversion paths, which is required for high entanglement visibility.

  17. Freeform solar concentrator with a highly asymmetric acceptance cone

    NASA Astrophysics Data System (ADS)

    Wheelwright, Brian; Angel, J. Roger P.; Coughenour, Blake; Hammer, Kimberly

    2014-10-01

    A solar concentrator with a highly asymmetric acceptance cone is investigated. Concentrating photovoltaic systems require dual-axis sun tracking to maintain nominal concentration throughout the day. In addition to collecting direct rays from the solar disk, which subtends ~0.53 degrees, concentrating optics must allow for in-field tracking errors due to mechanical misalignment of the module, wind loading, and control loop biases. The angular range over which the concentrator maintains <90% of on-axis throughput is defined as the optical acceptance angle. Concentrators with substantial rotational symmetry likewise exhibit rotationally symmetric acceptance angles. In the field, this is sometimes a poor match with azimuth-elevation trackers, which have inherently asymmetric tracking performance. Pedestal-mounted trackers with low torsional stiffness about the vertical axis have better elevation tracking than azimuthal tracking. Conversely, trackers which rotate on large-footprint circular tracks are often limited by elevation tracking performance. We show that a line-focus concentrator, composed of a parabolic trough primary reflector and freeform refractive secondary, can be tailored to have a highly asymmetric acceptance angle. The design is suitable for a tracker with excellent tracking accuracy in the elevation direction, and poor accuracy in the azimuthal direction. In the 1000X design given, when trough optical errors (2mrad rms slope deviation) are accounted for, the azimuthal acceptance angle is +/- 1.65°, while the elevation acceptance angle is only +/-0.29°. This acceptance angle does not include the angular width of the sun, which consumes nearly all of the elevation tolerance at this concentration level. By decreasing the average concentration, the elevation acceptance angle can be increased. This is well-suited for a pedestal alt-azimuth tracker with a low cost slew bearing (without anti-backlash features).

  18. Humor in the eye tracker: attention capture and distraction from context cues.

    PubMed

    Strick, Madelijn; Holland, Rob W; Van Baaren, Rick; Van Knippenberg, Ad

    2010-01-01

    The humor effect refers to a robust finding in memory research that humorous information is easily recalled, at the expense of recall of nonhumorous information that was encoded in close temporal proximity. Previous research suggests that memory retrieval processes underlie this effect. That is, free recall is biased toward humorous information, which interferes with the retrieval of nonhumorous information. The present research tested an additional explanation that has not been specifically addressed before: Humor receives enhanced attention during information encoding, which decreases attention for context information. Participants observed humorous, nonhumorous positive, and nonhumorous neutral texts paired with novel consumer brands, while their eye movements were recorded using eye-tracker technology. The results confirmed that humor receives prolonged attention relative to both positive and neutral nonhumorous information. This enhanced attention correlated with impaired brand recognition.

  19. The anteroposterior axis of the tibia in Korean patients undergoing total knee replacement.

    PubMed

    Kim, C W; Seo, S S; Kim, J H; Roh, S M; Lee, C R

    2014-11-01

    The aim of this study was to find anatomical landmarks for rotational alignment of the tibial component in total knee replacement (TKR) in a CT-based study. Pre-operative CT scanning was performed on 94 South Korean patients (nine men, 85 women, 188 knees) with osteoarthritis of the knee joint prior to TKR. The tibial anteroposterior (AP) axis was defined as a line perpendicular to the femoral surgical transepicondylar axis and passing through the centre of the posterior cruciate ligament (PCL). The angles between the defined tibial AP axis and anatomical landmarks at various levels of the tibia were measured. The mean values of the angles between the defined tibial AP axis and the line connecting the anterior border of the proximal third of the tibia to the centre of the PCL was -0.2° (-17 to 14.1, sd 4.1). This was very close to the defined tibial axis, and remained so regardless of lower limb alignment and the degree of tibial bowing. Therefore, AP axis defined as described, is a reliable anatomical landmark for rotational alignment of tibial components. ©2014 The British Editorial Society of Bone & Joint Surgery.

  20. A Parametric Approach to Numerical Modeling of TKR Contact Forces

    PubMed Central

    Lundberg, Hannah J.; Foucher, Kharma C.; Wimmer, Markus A.

    2009-01-01

    In vivo knee contact forces are difficult to determine using numerical methods because there are more unknown forces than equilibrium equations available. We developed parametric methods for computing contact forces across the knee joint during the stance phase of level walking. Three-dimensional contact forces were calculated at two points of contact between the tibia and the femur, one on the lateral aspect of the tibial plateau, and one on the medial side. Muscle activations were parametrically varied over their physiologic range resulting in a solution space of contact forces. The obtained solution space was reasonably small and the resulting force pattern compared well to a previous model from the literature for kinematics and external kinetics from the same patient. Peak forces of the parametric model and the previous model were similar for the first half of the stance phase, but differed for the second half. The previous model did not take into account the transverse external moment about the knee and could not calculate muscle activation levels. Ultimately, the parametric model will result in more accurate contact force inputs for total knee simulators, as current inputs are not generally based on kinematics and kinetics inputs from TKR patients. PMID:19155015

  1. RNA sequencing to determine the contribution of kinase receptor transactivation to G protein coupled receptor signalling in vascular smooth muscle cells.

    PubMed

    Kamato, Danielle; Bhaskarala, Venkata Vijayanand; Mantri, Nitin; Oh, Tae Gyu; Ling, Dora; Janke, Reearna; Zheng, Wenhua; Little, Peter J; Osman, Narin

    2017-01-01

    G protein coupled receptor (GPCR) signalling covers three major mechanisms. GPCR agonist engagement allows for the G proteins to bind to the receptor leading to a classical downstream signalling cascade. The second mechanism is via the utilization of the β-arrestin signalling molecule and thirdly via transactivation dependent signalling. GPCRs can transactivate protein tyrosine kinase receptors (PTKR) to activate respective downstream signalling intermediates. In the past decade GPCR transactivation dependent signalling was expanded to show transactivation of serine/threonine kinase receptors (S/TKR). Kinase receptor transactivation enormously broadens the GPCR signalling paradigm. This work utilizes next generation RNA-sequencing to study the contribution of transactivation dependent signalling to total protease activated receptor (PAR)-1 signalling. Transactivation, assessed as gene expression, accounted for 50 percent of the total genes regulated by thrombin acting through PAR-1 in human coronary artery smooth muscle cells. GPCR transactivation of PTKRs is approximately equally important as the transactivation of the S/TKR with 209 and 177 genes regulated respectively, via either signalling pathway. This work shows that genome wide studies can provide powerful insights into GPCR mediated signalling pathways.

  2. Time-Of-Flight Camera, Optical Tracker and Computed Tomography in Pairwise Data Registration.

    PubMed

    Pycinski, Bartlomiej; Czajkowska, Joanna; Badura, Pawel; Juszczyk, Jan; Pietka, Ewa

    2016-01-01

    A growing number of medical applications, including minimal invasive surgery, depends on multi-modal or multi-sensors data processing. Fast and accurate 3D scene analysis, comprising data registration, seems to be crucial for the development of computer aided diagnosis and therapy. The advancement of surface tracking system based on optical trackers already plays an important role in surgical procedures planning. However, new modalities, like the time-of-flight (ToF) sensors, widely explored in non-medical fields are powerful and have the potential to become a part of computer aided surgery set-up. Connection of different acquisition systems promises to provide a valuable support for operating room procedures. Therefore, the detailed analysis of the accuracy of such multi-sensors positioning systems is needed. We present the system combining pre-operative CT series with intra-operative ToF-sensor and optical tracker point clouds. The methodology contains: optical sensor set-up and the ToF-camera calibration procedures, data pre-processing algorithms, and registration technique. The data pre-processing yields a surface, in case of CT, and point clouds for ToF-sensor and marker-driven optical tracker representation of an object of interest. An applied registration technique is based on Iterative Closest Point algorithm. The experiments validate the registration of each pair of modalities/sensors involving phantoms of four various human organs in terms of Hausdorff distance and mean absolute distance metrics. The best surface alignment was obtained for CT and optical tracker combination, whereas the worst for experiments involving ToF-camera. The obtained accuracies encourage to further develop the multi-sensors systems. The presented substantive discussion concerning the system limitations and possible improvements mainly related to the depth information produced by the ToF-sensor is useful for computer aided surgery developers.

  3. Intimacy and Distancing: Young Men's Conversations about Romantic Relationships

    ERIC Educational Resources Information Center

    Korobov, Neill; Thorne, Avril

    2006-01-01

    This study examined how 32 pairs of 19-to 22-year-old Euro-American male friends constructed intimacy when telling romantic-relationship stories in casual conversations. Analyses centered on the emergence of two types of conversational positions: intimate positions and distancing positions. Intimate positions constructed young men as warm, caring,…

  4. Supercurrent in ferromagnetic Josephson junctions with heavy metal interlayers

    NASA Astrophysics Data System (ADS)

    Satchell, Nathan; Birge, Norman O.

    2018-06-01

    The length scale over which supercurrent from conventional BCS, s -wave superconductors (S ) can penetrate an adjacent ferromagnetic (F ) layer depends on the ability to convert singlet Cooper pairs into triplet Cooper pairs. Spin-aligned triplet Cooper pairs are not dephased by the ferromagnetic exchange interaction and can thus penetrate an F layer over much longer distances than singlet Cooper pairs. These triplet Cooper pairs carry a dissipationless spin current and are the fundamental building block for the fledgling field of superspintronics. Singlet-triplet conversion by inhomogeneous magnetism is well established. Here, we describe an attempt to use spin-orbit coupling as an alternative mechanism to mediate singlet-triplet conversion in S-F-S Josephson junctions. We report that the addition of thin Pt spin-orbit-coupling layers in our Josephson junctions significantly increases supercurrent transmission, however the decay length of the supercurrent is not found to increase. We attribute the increased supercurrent transmission to Pt acting as a buffer layer to improve the growth of the Co F layer.

  5. Searches for long-lived charged particles in pp collisions at $$ \\sqrt{s} $$ =7 and 8 TeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chatrchyan, S.; Khachatryan, V.; Sirunyan, A. M.

    2013-07-01

    Results of searches for heavy stable charged particles produced in pp collisions at = 7 and 8 TeV are presented corresponding to an integrated luminosity of 5.0 fb(-1) and 18.8 fb(-1), respectively. Data collected with the CMS detector are used to study the momentum, energy deposition, and time-of-flight of signal candidates. Leptons with an electric charge between e/3 and 8e, as well as bound states that can undergo charge exchange with the detector material, are studied. Analysis results are presented for various combinations of signatures in the inner tracker only, inner tracker and muon detector, and muon detector only. Detectormore » signatures utilized are long time-of-flight to the outer muon system and anomalously high (or low) energy deposition in the inner tracker. The data are consistent with the expected background, and upper limits are set on the production cross section of long-lived gluinos, scalar top quarks, and scalar τ leptons, as well as pair produced long-lived leptons. Corresponding lower mass limits, ranging up to 1322 GeV/c (2) for gluinos, are the most stringent to date.« less

  6. Searches for long-lived charged particles in pp collisions at $$\\sqrt{s}$$ = 7 and 8 TeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chatrchyan, S.; Khachatryan, V.; Sirunyan, A. M.

    2013-07-19

    Results of searches for heavy stable charged particles produced in pp collisions atmore » $$\\sqrt{s}$$ =7 and 8 TeV are presented corresponding to an integrated luminosity of 5.0 fb -1 and 18.8 fb -1, respectively. Data collected with the CMS detector are used to study the momentum, energy deposition, and time-of-flight of signal candidates. Leptons with an electric charge between e/3 and 8e, as well as bound states that can undergo charge exchange with the detector material, are studied. Analysis results are presented for various combinations of signatures in the inner tracker only, inner tracker and muon detector, and muon detector only. Detector signatures utilized are long time-of-flight to the outer muon system and anomalously high (or low) energy deposition in the inner tracker. The data are consistent with the expected background, and upper limits are set on the production cross section of long-lived gluinos, scalar top quarks, and scalar τ leptons, as well as pair produced long-lived leptons. Corresponding lower mass limits, ranging up to 1322 GeV/c (2) for gluinos, are the most stringent to date.« less

  7. Interactive computer simulations of knee-replacement surgery.

    PubMed

    Gunther, Stephen B; Soto, Gabriel E; Colman, William W

    2002-07-01

    Current surgical training programs in the United States are based on an apprenticeship model. This model is outdated because it does not provide conceptual scaffolding, promote collaborative learning, or offer constructive reinforcement. Our objective was to create a more useful approach by preparing students and residents for operative cases using interactive computer simulations of surgery. Total-knee-replacement surgery (TKR) is an ideal procedure to model on the computer because there is a systematic protocol for the procedure. Also, this protocol is difficult to learn by the apprenticeship model because of the multiple instruments that must be used in a specific order. We designed an interactive computer tutorial to teach medical students and residents how to perform knee-replacement surgery. We also aimed to reinforce the specific protocol of the operative procedure. Our final goal was to provide immediate, constructive feedback. We created a computer tutorial by generating three-dimensional wire-frame models of the surgical instruments. Next, we applied a surface to the wire-frame models using three-dimensional modeling. Finally, the three-dimensional models were animated to simulate the motions of an actual TKR. The tutorial is a step-by-step tutorial that teaches and tests the correct sequence of steps in a TKR. The student or resident must select the correct instruments in the correct order. The learner is encouraged to learn the stepwise surgical protocol through repetitive use of the computer simulation. Constructive feedback is acquired through a grading system, which rates the student's or resident's ability to perform the task in the correct order. The grading system also accounts for the time required to perform the simulated procedure. We evaluated the efficacy of this teaching technique by testing medical students who learned by the computer simulation and those who learned by reading the surgical protocol manual. Both groups then performed TKR on manufactured bone models using real instruments. Their technique was graded with the standard protocol. The students who learned on the computer simulation performed the task in a shorter time and with fewer errors than the control group. They were also more engaged in the learning process. Surgical training programs generally lack a consistent approach to preoperative education related to surgical procedures. This interactive computer tutorial has allowed us to make a quantum leap in medical student and resident teaching in our orthopedic department because the students actually participate in the entire process. Our technique provides a linear, sequential method of skill acquisition and direct feedback, which is ideally suited for learning stepwise surgical protocols. Since our initial evaluation has shown the efficacy of this program, we have implemented this teaching tool into our orthopedic curriculum. Our plans for future work with this simulator include modeling procedures involving other anatomic areas of interest, such as the hip and shoulder.

  8. The effectiveness of Kinesio Taping® after total knee replacement in early postoperative rehabilitation period. A randomized controlled trial.

    PubMed

    Donec, V; Kriščiūnas, A

    2014-08-01

    The number of total knee replacements performed each year is increasing. Among the main impediments to functional recovery after these surgeries include postoperative edema, pain, lower limb muscle strength deficits, all of which point to a need to identify safe, effective postoperative rehabilitation modalities. The aim of this paper was to evaluate the effectiveness of Kinesio Taping® (KT) method in reducing postoperative pain, edema, and improved knee range of motion recovery after total knee replacement (TKR) operation in early postoperative rehabilitation period. Randomized clinical trial. Inpatient rehabilitation facility. Ninety-four patients, who underwent primary TKR surgery. Using simple randomization, participants were divided into KT group and control group. Both groups received same rehabilitation program and procedures after surgery, except KT group also received KT applications throughout all rehabilitation period. Postoperative pain, edema, restoration of the operated knee flexion and extension were evaluated. The chosen level of significance was P<0.05; in evaluation power of the test β ≤ 0.2. Groups were homogenous to sex, age, BMI, comorbidities, preoperative knee flexion/extension impairment, preoperative pain intensity, anaesthesia, prosthesis implanted (P>0.05). In both groups postoperative pain decreased significantly during rehabilitation period, however less pain was found in KT group from the second postoperative week till the end of inpatient rehabilitation (28th postoperative day) (P<0.05; β ≤ 0.2). Postoperative edema was less intense and subsided more quickly in KT group as well (P<0.05; β ≤ 0.2). No difference was found in improvement of knee flexion (P>0.05). Operated knee extension was found better in KT group then in control at the end of in-patient rehabilitation (P<0.05; β ≤ 0.2). KT was well tolerated by patients. KT technique appeared to be beneficial for reducing postoperative pain, edema, improving knee extension in early postoperative rehabilitation period. This finding implies for health care professionals working in the field of physical medicine and rehabilitation that Kinesio Taping® method is safe and can be used as additional rehabilitation means for patients after TKR.

  9. Entangled photon pair generation by spontaneous parametric down-conversion in finite-length one-dimensional photonic crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Centini, M.; Sciscione, L.; Sibilia, C.

    A description of spontaneous parametric down-conversion in finite-length one-dimensional nonlinear photonic crystals is developed using semiclassical and quantum approaches. It is shown that if a suitable averaging is added to the semiclassical model, its results are in very good agreement with the quantum approach. We propose two structures made with GaN/AlN that generate both degenerate and nondegenerate entangled photon pairs. Both structures are designed so as to achieve a high efficiency of the nonlinear process.

  10. Talk with Your Mother or Your Sibling? Developmental Changes in Early Family Conversations about Feelings.

    ERIC Educational Resources Information Center

    Brown, Jane R.; Dunn, Judy

    1992-01-01

    Developmental changes in the pattern of 50 families' conversations about feelings were examined when the families' second-born children were 33 and 47 months old. The total amount of talk and the frequency of talk about feelings between sibling pairs increased, whereas the amount of mother-child conversation and references to feelings decreased.…

  11. Digitization of Analog Signals using a Field Programmable Gate Array (FPGA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguilera, Daniel; Rusu, Vadim

    The idea of this research is consolidating the electrical components used for capturing data in the Mu2e Tracker. Ideally, an FPGA will serve as the Time-Division Converters (TDC) and Analog-to-Digital Converters (ADC). The TDC is already being carried out by the FPGA, but we are still using off the shelf ADCs. This poster proposes using Low Voltage Differential Signaling as the basis for analog-to-digital conversion using and FPGA.

  12. Web Camera Based Eye Tracking to Assess Visual Memory on a Visual Paired Comparison Task.

    PubMed

    Bott, Nicholas T; Lange, Alex; Rentz, Dorene; Buffalo, Elizabeth; Clopton, Paul; Zola, Stuart

    2017-01-01

    Background: Web cameras are increasingly part of the standard hardware of most smart devices. Eye movements can often provide a noninvasive "window on the brain," and the recording of eye movements using web cameras is a burgeoning area of research. Objective: This study investigated a novel methodology for administering a visual paired comparison (VPC) decisional task using a web camera.To further assess this method, we examined the correlation between a standard eye-tracking camera automated scoring procedure [obtaining images at 60 frames per second (FPS)] and a manually scored procedure using a built-in laptop web camera (obtaining images at 3 FPS). Methods: This was an observational study of 54 clinically normal older adults.Subjects completed three in-clinic visits with simultaneous recording of eye movements on a VPC decision task by a standard eye tracker camera and a built-in laptop-based web camera. Inter-rater reliability was analyzed using Siegel and Castellan's kappa formula. Pearson correlations were used to investigate the correlation between VPC performance using a standard eye tracker camera and a built-in web camera. Results: Strong associations were observed on VPC mean novelty preference score between the 60 FPS eye tracker and 3 FPS built-in web camera at each of the three visits ( r = 0.88-0.92). Inter-rater agreement of web camera scoring at each time point was high (κ = 0.81-0.88). There were strong relationships on VPC mean novelty preference score between 10, 5, and 3 FPS training sets ( r = 0.88-0.94). Significantly fewer data quality issues were encountered using the built-in web camera. Conclusions: Human scoring of a VPC decisional task using a built-in laptop web camera correlated strongly with automated scoring of the same task using a standard high frame rate eye tracker camera.While this method is not suitable for eye tracking paradigms requiring the collection and analysis of fine-grained metrics, such as fixation points, built-in web cameras are a standard feature of most smart devices (e.g., laptops, tablets, smart phones) and can be effectively employed to track eye movements on decisional tasks with high accuracy and minimal cost.

  13. Noncontact bimolecular photoionization followed by radical-ions separation and their geminate recombination assisted by coherent HFI induced spin-conversion.

    PubMed

    Dodin, Dmitry V; Ivanov, Anatoly I; Burshtein, Anatoly I

    2008-02-07

    The Hamiltonian description of the spin-conversion induced by a hyperfine interaction (HFI) in photogenerated radical-ion pairs is substituted for the rate (incoherent) description of the same conversion provided by the widely used earlier elementary spin model. The quantum yields of the free ions as well as the singlet and triplet products of geminate recombination are calculated using distant dependent ionization and recombination rates, instead of their contact analogs. Invoking the simplest models of these rates, we demonstrate with the example of a spin-less system that the diffusional acceleration of radical-ion pair recombination at lower viscosity gives way to its diffusional deceleration (Angulo effect), accomplished with a kinetic plateau inherent with the primitive exponential model. Qualitatively the same behavior is found in real systems, assuming both ionization and recombination is carried out by the Marcus electron-transfer rates. Neglecting the Coulomb interaction between solvated ions, the efficiencies of radical-ion pair recombination to the singlet and triplet products are well fitted to the available experimental data. The magnetic field dependence of these yields is specified.

  14. Detection of Orthopaedic Implants by Airport Metal Detectors

    PubMed Central

    Abbassian, Ali; Datla, Balarama; Brooks, RA

    2007-01-01

    INTRODUCTION We performed a questionnaire study to establish the frequency and consequences of the detection of orthopaedic implants by airport security and to help us advise patients correctly. All published literature on this subject is based on experimental studies and no ‘real-life’ data are available. PATIENTS AND METHODS A total of 200 patients with a variety of implants were identified. All patients were sent a postal questionnaire enquiring about their experience with airport security since their surgery. RESULTS Of the cohort, 154 (77%) patients responded. About half of the implants (47%) were detected, but the majority of patients (72%) were not significantly inconvenienced. When detected, only 9% of patients were asked for documentary evidence of their implant. We also found that patients with a total knee replacement (TKR) had a greater chance of detection as compared to those with a total hip replacement (THR; 71% versus 31%; P = 0.03). CONCLUSIONS All patients, and in particular those with a TKR, can be re-assured that, although they have a fair chance of detection by airport security, a major disruption to their journey is unlikely. We advise that documentation to prove the presence of an orthopaedic implant should be offered to those who are concerned about the potential for inconvenience, but such documentation is not required routinely. PMID:17394716

  15. Detection of orthopaedic implants by airport metal detectors.

    PubMed

    Abbassian, Ali; Datla, Balarama; Brooks, R A

    2007-04-01

    We performed a questionnaire study to establish the frequency and consequences of the detection of orthopaedic implants by airport security and to help us advise patients correctly. All published literature on this subject is based on experimental studies and no 'real-life' data are available. A total of 200 patients with a variety of implants were identified. All patients were sent a postal questionnaire enquiring about their experience with airport security since their surgery. Of the cohort, 154 (77%) patients responded. About half of the implants (47%) were detected, but the majority of patients (72%) were not significantly inconvenienced. When detected, only 9% of patients were asked for documentary evidence of their implant. We also found that patients with a total knee replacement (TKR) had a greater chance of detection as compared to those with a total hip replacement (THR; 71% versus 31%; P = 0.03). All patients, and in particular those with a TKR, can be re-assured that, although they have a fair chance of detection by airport security, a major disruption to their journey is unlikely. We advise that documentation to prove the presence of an orthopaedic implant should be offered to those who are concerned about the potential for inconvenience, but such documentation is not required routinely.

  16. Cost-effectiveness of hydrotherapy versus land-based therapy in patients with musculoskeletal disorders in Singapore.

    PubMed

    Teng, Monica; Zhou, Hui Jun; Lin, Liang; Lim, Pang Hung; Yeo, Doreen; Goh, Suzanne; Tjan, Soon Yin; Lim, Boon Peng

    2018-03-09

    The study evaluated the cost-effectiveness of hydrotherapy versus land-based therapy in patients with musculoskeletal disorders (MSDs) in Singapore. A decision-analytic model was constructed to compare the cost-effectiveness of hydrotherapy to land-based therapy over 3 months from societal perspective. Target population comprised patients with low back pain (LBP), osteoarthritis (OA), rheumatoid arthritis (RA), total hip replacement (THR) and total knee replacement (TKR). Subgroup analyses were carried out to determine the cost-effectiveness of hydrotherapy in individual MSDs. Relative treatment effects were obtained through a systematic review of published data. Compared to land-based therapy, hydrotherapy was associated with an incremental cost-effectiveness ratio (ICER) of SGD 27 471 per quality-adjusted life-year (QALY) gained, which was below the willingness-to-pay threshold of SGD 70 000 per QALY (one gross domestic product per capita in Singapore in 2015). For the respective MSDs, hydrotherapy were dominant (more effective and less costly) in THR and TKR, cost-effective for LBP and RA, and not cost-effective for OA. Treatment adherence and cost of hydrotherapy were key drivers to the ICER values. Hydrotherapy was a cost-effective rehabilitation compared to land-based therapy for a population with MSDs in Singapore. However, the benefit of hydrotherapy was not observed in patients with OA.

  17. Small Orbital Stereo Tracking Camera Technology Development

    NASA Technical Reports Server (NTRS)

    Bryan, Tom; MacLeod, Todd; Gagliano, Larry

    2017-01-01

    Any exploration vehicle assembled or Spacecraft placed in LEO or GTO must pass through this debris cloud and survive. Large cross section, low thrust vehicles will spend more time spiraling out through the cloud and will suffer more impacts.Better knowledge of small debris will improve survival odds. Current estimated Density of debris at various orbital attitudes with notation of recent collisions and resulting spikes. Orbital Debris Tracking and Characterization has now been added to NASA Office of Chief Technologists Technology Development Roadmap in Technology Area 5 (TA5.7)[Orbital Debris Tracking and Characterization] and is a technical gap in the current National Space Situational Awareness necessary to safeguard orbital assets and crews due to the risk of Orbital Debris damage to ISS Exploration vehicles. The Problem: Traditional orbital trackers looking for small, dim orbital derelicts and debris typically will stare at the stars and let any reflected light off the debris integrate in the imager for seconds, thus creating a streak across the image. The Solution: The Small Tracker will see Stars and other celestial objects rise through its Field of View (FOV) at the rotational rate of its orbit, but the glint off of orbital objects will move through the FOV at different rates and directions. Debris on a head-on collision course (or close) will stay in the FOV at 14 Km per sec. The Small Tracker can track at 60 frames per sec allowing up to 30 fixes before a near-miss pass. A Stereo pair of Small Trackers can provide range data within 5-7 Km for better orbit measurements.

  18. To Converse with Creation: Saving California Indian Languages.

    ERIC Educational Resources Information Center

    Whittemore, Katharine

    1997-01-01

    Describes the Master-Apprentice Language Learning Program, which seeks to save endangered Native Californian languages by pairing speakers and nonspeakers and providing the pairs with materials, technical support, and personal support. Briefly discusses the history of American Indian genocide and language extinction in California. Includes…

  19. Time-Of-Flight Camera, Optical Tracker and Computed Tomography in Pairwise Data Registration

    PubMed Central

    Badura, Pawel; Juszczyk, Jan; Pietka, Ewa

    2016-01-01

    Purpose A growing number of medical applications, including minimal invasive surgery, depends on multi-modal or multi-sensors data processing. Fast and accurate 3D scene analysis, comprising data registration, seems to be crucial for the development of computer aided diagnosis and therapy. The advancement of surface tracking system based on optical trackers already plays an important role in surgical procedures planning. However, new modalities, like the time-of-flight (ToF) sensors, widely explored in non-medical fields are powerful and have the potential to become a part of computer aided surgery set-up. Connection of different acquisition systems promises to provide a valuable support for operating room procedures. Therefore, the detailed analysis of the accuracy of such multi-sensors positioning systems is needed. Methods We present the system combining pre-operative CT series with intra-operative ToF-sensor and optical tracker point clouds. The methodology contains: optical sensor set-up and the ToF-camera calibration procedures, data pre-processing algorithms, and registration technique. The data pre-processing yields a surface, in case of CT, and point clouds for ToF-sensor and marker-driven optical tracker representation of an object of interest. An applied registration technique is based on Iterative Closest Point algorithm. Results The experiments validate the registration of each pair of modalities/sensors involving phantoms of four various human organs in terms of Hausdorff distance and mean absolute distance metrics. The best surface alignment was obtained for CT and optical tracker combination, whereas the worst for experiments involving ToF-camera. Conclusion The obtained accuracies encourage to further develop the multi-sensors systems. The presented substantive discussion concerning the system limitations and possible improvements mainly related to the depth information produced by the ToF-sensor is useful for computer aided surgery developers. PMID:27434396

  20. High-Fidelity Down-Conversion Source for Secure Communications Using On-Demand Single Photons

    NASA Technical Reports Server (NTRS)

    Roberts, Tony

    2015-01-01

    AdvR, Inc., has built an efficient, fully integrated, waveguide-based source of spectrally uncorrelated photon pairs that will accelerate research and development (R&D) in the emerging field of quantum information science. Key to the innovation is the use of submicron periodically poled waveguides to produce counter propagating photon pairs, which is enabled by AdvR's patented segmented microelectrode poling technique. This novel device will provide a high brightness source of down-conversion pairs with enhanced spectral properties and low attenuation, and it will operate in the visible to the mid-infrared spectral region. A waveguide-based source of spectrally and spatially pure heralded photons will contribute to a wide range of NASA's advanced technology development efforts, including on-demand single photon sources for high-rate spaced-based secure communications.

  1. Interpreting anomalous electron pairs as new particle decays

    NASA Astrophysics Data System (ADS)

    Wilczynski, Henryk

    1999-08-01

    In heavy particle decays found in cosmic ray interactions recorded in the JACEE emulsion chambers, multiple electron pairs were previously reported. These pairs apparently originated from conversions of photons emitted in the decays. It is difficult to explain the overall properties of these decays in terms of known heavy particle decay modes. A recently published compilation of low-energy nuclear data suggests existence of excess electron pairs with invariant mass about 9 MeV/c2 , which may be explained by postulating a new neutral boson decaying into the electron pair. The feasibility of explaining the JACEE electron pairs with this hypothesis is presented.

  2. Particle identification using the time-over-threshold measurements in straw tube detectors

    NASA Astrophysics Data System (ADS)

    Jowzaee, S.; Fioravanti, E.; Gianotti, P.; Idzik, M.; Korcyl, G.; Palka, M.; Przyborowski, D.; Pysz, K.; Ritman, J.; Salabura, P.; Savrie, M.; Smyrski, J.; Strzempek, P.; Wintz, P.

    2013-08-01

    The identification of charged particles based on energy losses in straw tube detectors has been simulated. The response of a new front-end chip developed for the PANDA straw tube tracker was implemented in the simulations and corrections for track distance to sense wire were included. Separation power for p - K, p - π and K - π pairs obtained using the time-over-threshold technique was compared with the one based on the measurement of collected charge.

  3. System Size and Energy Dependence on Strangeness Production in 22 GeV Cu+Cu Collisions at RHIC

    DTIC Science & Technology

    2011-05-10

    relativistic speeds approaching the speed of light before they meet in an extremely high temperature collision. The Solenoidal Tracker at RHIC (STAR...extremely high energy and temperature. This project determines the yield of strange quarks through measurements of K0-short mesons as well as Lambda and Anti...charge. These quarks are never observed alone, but are observable in the form of baryons (3 quarks) or mesons (a quark-anti-quark pair). The

  4. Performance evaluation of multiple (32 channels) sub-nanosecond TDC implemented in low-cost FPGA

    NASA Astrophysics Data System (ADS)

    Lichard, P.; Konstantinou, G.; Villar Vilanueva, A.; Palladino, V.

    2014-03-01

    NA62 experiment Straw tracker frontend board serves as a gas-tight detector cover and integrates two CARIOCA chips, a low cost FPGA (Cyclon III, Altera) and a set of 400Mbit/s links to the backend. The FPGA houses 16 pairs of sub-nanosecond resolution TDCs with derandomizers and an output link serializer. Evaluation methods, including simulations, and performance results of the system in the lab and on a detector prototype are presented.

  5. Influence of Role-Switching on Phonetic Convergence in Conversation

    ERIC Educational Resources Information Center

    Pardo, Jennifer S.; Jay, Isabel Cajori; Hoshino, Risa; Hasbun, Sara Maria; Sowemimo-Coker, Chantal; Krauss, Robert M.

    2013-01-01

    The current study examined phonetic convergence when talkers alternated roles during conversational interaction. The talkers completed a map navigation task in which they alternated instruction Giver and Receiver roles across multiple map pairs. Previous studies found robust effects of the role of a talker on phonetic convergence, and it was…

  6. Retrospective Analysis of Cognitive and Affective Responses in Intercultural and Intracultural Conversations

    ERIC Educational Resources Information Center

    Nguyen, Duyen T.; Fussell, Susan R.

    2015-01-01

    We report a study that uses retrospective analysis to understand the relationships between American and Chinese participants' utterances during a conversation and the moment-by-moment feelings and reactions they subsequently described. Intercultural and intracultural pairs of Chinese and American participants talked about a fictional crime story…

  7. Einstein-Podolsky-Rosen-Bohm experiment and Bell inequality violation using Type 2 parametric down conversion

    NASA Technical Reports Server (NTRS)

    Kiess, Thomas E.; Shih, Yan-Hua; Sergienko, A. V.; Alley, Carroll O.

    1994-01-01

    We report a new two-photon polarization correlation experiment for realizing the Einstein-Podolsky-Rosen-Bohm (EPRB) state and for testing Bell-type inequalities. We use the pair of orthogonally-polarized light quanta generated in Type 2 parametric down conversion. Using 1 nm interference filters in front of our detectors, we observe from the output of a 0.5mm beta - BaB2O4 (BBO) crystal the EPRB correlations in coincidence counts, and measure an associated Bell inequality violation of 22 standard deviations. The quantum state of the photon pair is a polarization analog of the spin-1/2 singlet state.

  8. Peer Coaching Through mHealth Targeting Physical Activity in People With Parkinson Disease: Feasibility Study.

    PubMed

    Colón-Semenza, Cristina; Latham, Nancy K; Quintiliani, Lisa M; Ellis, Terry D

    2018-02-15

    Long-term engagement in exercise and physical activity mitigates the progression of disability and increases quality of life in people with Parkinson disease (PD). Despite this, the vast majority of individuals with PD are sedentary. There is a critical need for a feasible, safe, acceptable, and effective method to assist those with PD to engage in active lifestyles. Peer coaching through mobile health (mHealth) may be a viable approach. The purpose of this study was to develop a PD-specific peer coach training program and a remote peer-mentored walking program using mHealth technology with the goal of increasing physical activity in persons with PD. We set out to examine the feasibility, safety, and acceptability of the programs along with preliminary evidence of individual-level changes in walking activity, self-efficacy, and disability in the peer mentees. A peer coach training program and a remote peer-mentored walking program using mHealth was developed and tested in 10 individuals with PD. We matched physically active persons with PD (peer coaches) with sedentary persons with PD (peer mentees), resulting in 5 dyads. Using both Web-based and in-person delivery methods, we trained the peer coaches in basic knowledge of PD, exercise, active listening, and motivational interviewing. Peer coaches and mentees wore FitBit Zip activity trackers and participated in daily walking over 8 weeks. Peer dyads interacted daily via the FitBit friends mobile app and weekly via telephone calls. Feasibility was determined by examining recruitment, participation, and retention rates. Safety was assessed by monitoring adverse events during the study period. Acceptability was assessed via satisfaction surveys. Individual-level changes in physical activity were examined relative to clinically important differences. Four out of the 5 peer pairs used the FitBit activity tracker and friends function without difficulty. A total of 4 of the 5 pairs completed the 8 weekly phone conversations. There were no adverse events over the course of the study. All peer coaches were "satisfied" or "very satisfied" with the training program, and all participants were "satisfied" or "very satisfied" with the peer-mentored walking program. All participants would recommend this program to others with PD. Increases in average steps per day exceeding the clinically important difference occurred in 4 out of the 5 mentees. Remote peer coaching using mHealth is feasible, safe, and acceptable for persons with PD. Peer coaching using mHealth technology may be a viable method to increase physical activity in individuals with PD. Larger controlled trials are necessary to examine the effectiveness of this approach. ©Cristina Colón-Semenza, Nancy K Latham, Lisa M Quintiliani, Terry D Ellis. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 15.02.2018.

  9. Peer Coaching Through mHealth Targeting Physical Activity in People With Parkinson Disease: Feasibility Study

    PubMed Central

    Latham, Nancy K; Quintiliani, Lisa M

    2018-01-01

    Background Long-term engagement in exercise and physical activity mitigates the progression of disability and increases quality of life in people with Parkinson disease (PD). Despite this, the vast majority of individuals with PD are sedentary. There is a critical need for a feasible, safe, acceptable, and effective method to assist those with PD to engage in active lifestyles. Peer coaching through mobile health (mHealth) may be a viable approach. Objective The purpose of this study was to develop a PD-specific peer coach training program and a remote peer-mentored walking program using mHealth technology with the goal of increasing physical activity in persons with PD. We set out to examine the feasibility, safety, and acceptability of the programs along with preliminary evidence of individual-level changes in walking activity, self-efficacy, and disability in the peer mentees. Methods A peer coach training program and a remote peer-mentored walking program using mHealth was developed and tested in 10 individuals with PD. We matched physically active persons with PD (peer coaches) with sedentary persons with PD (peer mentees), resulting in 5 dyads. Using both Web-based and in-person delivery methods, we trained the peer coaches in basic knowledge of PD, exercise, active listening, and motivational interviewing. Peer coaches and mentees wore FitBit Zip activity trackers and participated in daily walking over 8 weeks. Peer dyads interacted daily via the FitBit friends mobile app and weekly via telephone calls. Feasibility was determined by examining recruitment, participation, and retention rates. Safety was assessed by monitoring adverse events during the study period. Acceptability was assessed via satisfaction surveys. Individual-level changes in physical activity were examined relative to clinically important differences. Results Four out of the 5 peer pairs used the FitBit activity tracker and friends function without difficulty. A total of 4 of the 5 pairs completed the 8 weekly phone conversations. There were no adverse events over the course of the study. All peer coaches were “satisfied” or “very satisfied” with the training program, and all participants were “satisfied” or “very satisfied” with the peer-mentored walking program. All participants would recommend this program to others with PD. Increases in average steps per day exceeding the clinically important difference occurred in 4 out of the 5 mentees. Conclusions Remote peer coaching using mHealth is feasible, safe, and acceptable for persons with PD. Peer coaching using mHealth technology may be a viable method to increase physical activity in individuals with PD. Larger controlled trials are necessary to examine the effectiveness of this approach. PMID:29449201

  10. Design, status and perspective of the Mu2e crystal calorimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pezzullo, G.; Atanov, N.; Baranov, V.

    The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-lessmore » $$\\mu \\to e$$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $$2.5\\cdot 10^{-17}$$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $$\\mu$$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. Here, in this paper we present the calorimeter design and the latest R&D results.« less

  11. Economic and clinical comparison of 2-octyl cyanoacrylate/polymer mesh tape with skin staples in total knee replacement.

    PubMed

    Sutton, Nadia; Schmitz, Niels-Derrek; Johnston, Stephen S

    2018-04-01

    To compare economic and clinical outcomes between skin staples and 2-octyl cyanoacrylate plus polymer mesh tape, Dermabond Prineo skin closure system, (SCS) among patients undergoing total knee replacement (TKR). Retrospective, observational study using the Premier Healthcare Database, which comprises hospital administrative and billing data for over 700 hospitals in the US. Patients selected for study had an elective hospital admission, with discharge occurring between January 2012 and September 2015, carrying primary ICD-9-CM procedure and diagnosis codes for TKR and osteoarthritis. Patients were classified into two mutually-exclusive groups based on billing records during the index admission: those with billing record(s) for the skin closure system (SCS group); and those with billing record(s) for skin staples (staple group). Primary outcomes were index admission's length of stay (LOS), total hospital costs, and discharge status (skilled nursing facility (SNF)/other versus home/home health-care); exploratory outcomes included operating room time (ORT) during index admission and 30, 60, and 90-day readmissions. The SCS and staple groups were propensity score matched (1:1/nearest neighbour/caliper=0.10) on patient, hospital, and provider characteristics. Multivariable regressions accounting for hospital-level clustering after matching were used to compare outcomes between study groups. Each group comprised 971 patients (1942 total patients; mean age: 65.3 years; female: 63.5%). The groups were generally well-balanced on matching covariates: mean standardised difference calculated across 49 covariates=0.049. Compared with the staple group, the SCS group had statistically significant shorter LOS (2.8 days versus 3.2 days, p=0.002), lower rate of discharge to SNF/other versus home/home health-care (26.4% versus 38.5%, p=0.011), and lower rate of 30, 60, and 90-day readmissions (30-day, 1.8% versus 4.4%, p=0.006; 60-day, 3.0% versus 5.4%, p<0.001; 90-day, 5.4% versus 7.4%, p=0.016). Differences between the groups for other outcomes were not statistically significant. Among patients undergoing TKR, use of the SCS was associated with shorter LOS, less resource intensive discharge status, and lower rates of all-cause readmission as compared with skin staples.

  12. Analgesic efficacy of low-dose intrathecal neostigmine in combination with fentanyl and bupivacaine for total knee replacement surgery

    PubMed Central

    Jain, Amit; Jain, Kajal; Bhardawaj, Neerja

    2012-01-01

    Background and Aim: Intrathecal (IT) neostigmine has been used as an adjunct to spinal anesthesia. The purpose of this study was to determine whether a combination of low-dose neostigmine IT would enhance analgesia of a fixed dose of fentanyl IT, in patients undergoing unilateral total knee replacement (TKR) surgery with spinal anesthesia. Settings and Design: Forty-five patients scheduled for unilateral TKR were randomized to one of the three groups (n = 15) and prospectively studied using placebo-controlled, double-blinded design. Materials and Methods: A 19-G epidural catheter was introduced through the L3–L4 interspace with patient in the sitting position, followed by spinal anesthesia administration through the L3–L4 interspace. Fifteen milligrams of hyperbaric bupivacaine (3 ml) plus the test drug (0.5 ml) was administered IT. The test drug was normal saline (0.5 ml) in group I; fentanyl 20 mcg (0.4 ml) and normal saline (0.1 ml) in group II; and fentanyl 20 mcg (0.4 ml) and neostigmine 1 mcg (0.1 ml) in group III. Characteristics of sensory and motor block, heart rate, and blood pressure were recorded intraoperatively. Postoperatively, pain scores, postoperative nausea and vomiting (PONV) scores, and sedation scores, and postoperative analgesic dose were recorded. Results: Forty-five patients were enrolled in this study and 43 patients were subjected to statistical analysis. Overall 24-h visual analog score in group III was significantly less than in those who received fentanyl alone (P = 0.00). The durations of complete analgesia and effective analgesia were longer for all patients in group III compared with group II (P < 0.05) and group I (P < 0.005) patients. The total number of epidural top ups (rescue analgesia) required was less in group II (P < 0.05) and group III (P < 0.005) patients, compared with the control group. The incidence of nausea and vomiting was not increased in group III patients. Conclusions: The addition of 1 mcg neostigmine IT increased the duration of analgesia and decreased the analgesic consumption in 24 h in TKR. There was no increase in the incidence of adverse effects. PMID:23225930

  13. Detecting Anastasis In Vivo by CaspaseTracker Biosensor.

    PubMed

    Tang, Ho Man; Fung, Ming Chiu; Tang, Ho Lam

    2018-02-01

    Anastasis (Greek for "rising to life") is a recently discovered cell recovery phenomenon whereby dying cells can reverse late-stage cell death processes that are generally assumed to be intrinsically irreversible. Promoting anastasis could in principle rescue or preserve injured cells that are difficult to replace such as cardiomyocytes or neurons, thereby facilitating tissue recovery. Conversely, suppressing anastasis in cancer cells, undergoing apoptosis after anti-cancer therapies, may ensure cancer cell death and reduce the chances of recurrence. However, these studies have been hampered by the lack of tools for tracking the fate of cells that undergo anastasis in live animals. The challenge is to identify the cells that have reversed the cell death process despite their morphologically normal appearance after recovery. To overcome this difficulty, we have developed Drosophila and mammalian CaspaseTracker biosensor systems that can identify and permanently track the anastatic cells in vitro or in vivo. Here, we present in vivo protocols for the generation and use of the CaspaseTracker dual biosensor system to detect and track anastasis in Drosophila melanogaster after transient exposure to cell death stimuli. While conventional biosensors and protocols can label cells actively undergoing apoptotic cell death, the CaspaseTracker biosensor can permanently label cells that have recovered after caspase activation - a hallmark of late-stage apoptosis, and simultaneously identify active apoptotic processes. This biosensor can also track the recovery of the cells that attempted other forms of cell death that directly or indirectly involved caspase activity. Therefore, this protocol enables us to continuously track the fate of these cells and their progeny, facilitating future studies of the biological functions, molecular mechanisms, physiological and pathological consequences, and therapeutic implications of anastasis. We also discuss the appropriate controls to distinguish cells that undergo anastasis from those that display non-apoptotic caspase activity in vivo.

  14. The tendency to sign-track predicts cue-induced reinstatement during nicotine self-administration, and is enhanced by nicotine but not ethanol.

    PubMed

    Versaggi, Cassandra L; King, Christopher P; Meyer, Paul J

    2016-08-01

    Some individuals are particularly responsive to reward-associated stimuli ("cues"), including the effects of these cues on craving and relapse to drug-seeking behavior. In the cases of nicotine and alcohol, cues may acquire these abilities via the incentive-enhancing properties of the drug. To determine the interaction between cue-responsivity and nicotine reinforcement, we studied the patterns of nicotine self-administration in rats categorized based on their tendency to approach a food-predictive cue ("sign-trackers") or a reward-delivery location ("goal-trackers"). In a second experiment, we determined whether nicotine and ethanol altered the incentive value of a food cue. Rats were classified as sign- or goal-trackers during a Pavlovian conditioned approach paradigm. Rats then self-administered intravenous nicotine (0.03 mg/kg infusions) followed by extinction and cue-induced reinstatement tests. We also tested the effects of nicotine (0.4 mg/kg base s.c.) or ethanol (0.7 g/kg i.p.) on the approach to, and reinforcing efficacy of, a food cue. Sign-trackers showed greater reinstatement in response to a nicotine cue. Further, nicotine enhanced sign-tracking but not goal-tracking to a food cue and also enhanced responding for the food cue during the conditioned reinforcement test. Conversely, ethanol reduced sign-tracking and increased goal-tracking, but had no effect on conditioned reinforcement. Our studies demonstrate that the tendency to attribute incentive value to a food cue predicts enhanced cue-induced reinstatement. Additionally, the incentive value of food cues is differentially modulated by nicotine and ethanol, which may be related to the reinforcing effects of these drugs.

  15. Effects of activity interference on annoyance due to aircraft noise

    NASA Technical Reports Server (NTRS)

    Willshire, K. F.; Powell, C. A.

    1981-01-01

    The effects of aircraft flyover noise on annoyance were compared for face to face conversation, reverie, and television viewing. Eighteen 5 minute sessions, each composed of three flyovers, were presented on each of 2 days to subjects in a simulated living room. Twelve pairs of females and 12 pairs of males were tested, once before and once after work. Flyovers varied in peak noise level from 53 to 83 dB, A weighted. On each day, subjects engaged in 18 sessions, six of conversation, six of television viewing, and six of reverie. The subjects completed subjective ratings of annoyance and acceptability following every session. Annoyance and unacceptability rating scores were significantly higher for the activity of television viewing compared to conversation or reverie. There was no difference between judgments during the latter two activities. No differences were found in the judgments when compared on the basis of "fatigue" (before/after work) or sex of the subject.

  16. Resonance coupling and polarization conversion in terahertz metasurfaces with twisted split-ring resonator pairs

    DOE PAGES

    Li, Chenyu; Chang, Chun-Chieh; Zhou, Qingli; ...

    2017-10-10

    Here, we investigate edge-coupling of twisted split-ring resonator (SRR) pairs in the terahertz (THz) frequency range. By using a simple coupled-resonator model we show that such a system exhibits resonance splitting and cross-polarization conversion. Numerical simulations and experimental measurements agree well with theoretical calculations, verifying the resonance splitting as a function of the coupling strength given by the SRR separation. We further show that a metal ground plane can be integrated to significantly enhance the resonance coupling, which enables the effective control of resonance splitting and the efficiency and bandwidth of the cross-polarization conversion. Our findings improve the fundamental understandingmore » of metamaterials with a view of accomplishing metamaterial functionalities with enhanced performance, which is of great interest in realizing THz functional devices required in a variety of applications.« less

  17. Probing CP violation in $$h\\rightarrow\\gamma\\gamma$$ with converted photons

    DOE PAGES

    Bishara, Fady; Grossman, Yuval; Harnik, Roni; ...

    2014-04-11

    We study Higgs diphoton decays, in which both photons undergo nuclear conversion to electron- positron pairs. The kinematic distribution of the two electron-positron pairs may be used to probe the CP violating (CPV) coupling of the Higgs to photons, that may be produced by new physics. Detecting CPV in this manner requires interference between the spin-polarized helicity amplitudes for both conversions. We derive leading order, analytic forms for these amplitudes. In turn, we obtain compact, leading-order expressions for the full process rate. While performing experiments involving photon conversions may be challenging, we use the results of our analysis to constructmore » experimental cuts on certain observables that may enhance sensitivity to CPV. We show that there exist regions of phase space on which sensitivity to CPV is of order unity. As a result, the statistical sensitivity of these cuts are verified numerically, using dedicated Monte-Carlo simulations.« less

  18. Apparatuses and method for converting electromagnetic radiation to direct current

    DOEpatents

    Kotter, Dale K; Novack, Steven D

    2014-09-30

    An energy conversion device may include a first antenna and a second antenna configured to generate an AC current responsive to incident radiation, at least one stripline, and a rectifier coupled with the at least one stripline along a length of the at least one stripline. An energy conversion device may also include an array of nanoantennas configured to generate an AC current in response to receiving incident radiation. Each nanoantenna of the array includes a pair of resonant elements, and a shared rectifier operably coupled to the pair of resonant elements, the shared rectifier configured to convert the AC current to a DC current. The energy conversion device may further include a bus structure operably coupled with the array of nanoantennas and configured to receive the DC current from the array of nanoantennas and transmit the DC current away from the array of nanoantennas.

  19. Circumferential electrocautery of the patella in primary total knee replacement without patellar replacement: a meta-analysis and systematic review

    PubMed Central

    Fan, Lihong; Ge, Zhaogang; Zhang, Chen; Li, Jia; Yu, Zefeng; Dang, Xiaoqian; Wang, Kunzheng

    2015-01-01

    The purpose of this meta-analysis and systematic review was to identify and assess whether circumferential electrocautery is useful for improving outcomes after primary total knee replacement(TKR). We searched MEDLINE, EMBASE, PubMed, SpringerLink, Web of Knowledge, OVID CINAHL, OVID EBM and Google Scholar and included articles published through January 2014. A total of 6 articles met the inclusion criteria. Of the 776 cases included in the analysis, 388 cases involved patellar denervation, and 388 cases were designated as the control group. The meta-analysis revealed no significant difference in the incidence of anterior knee pain (AKP, p = 0.18) or in the visual analogue scale score (VAS, p = 0.23) between the two groups. In addition, AKSS Function Score indicated no significant difference between the two groups (p = 0.28). However, the OKS (p = 0.02), patellar score (p = 0.01), AKSS-Knee Score (p = 0.004), range of motion (ROM, p < 0.0001) and WOMAC Score (p = 0.0003) indicated that circumpatellarelectrocautery improved clinical outcomes compared with non-electrocautery. The results indicate that circumferential electrocautery of the patella does not significantly improve AKP compared with non-electrocautery techniques but that circumferential electrocautery significantly improves patients' knee function after surgery. Therefore, we believe that circumferential electrocautery is beneficial to the outcome of primary TKR surgery without patellar replacement. PMID:25801456

  20. Circumferential electrocautery of the patella in primary total knee replacement without patellar replacement: a meta-analysis and systematic review.

    PubMed

    Fan, Lihong; Ge, Zhaogang; Zhang, Chen; Li, Jia; Yu, Zefeng; Dang, Xiaoqian; Wang, Kunzheng

    2015-03-24

    The purpose of this meta-analysis and systematic review was to identify and assess whether circumferential electrocautery is useful for improving outcomes after primary total knee replacement(TKR). We searched MEDLINE, EMBASE, PubMed, SpringerLink, Web of Knowledge, OVID CINAHL, OVID EBM and Google Scholar and included articles published through January 2014. A total of 6 articles met the inclusion criteria. Of the 776 cases included in the analysis, 388 cases involved patellar denervation, and 388 cases were designated as the control group. The meta-analysis revealed no significant difference in the incidence of anterior knee pain (AKP, p = 0.18) or in the visual analogue scale score (VAS, p = 0.23) between the two groups. In addition, AKSS Function Score indicated no significant difference between the two groups (p = 0.28). However, the OKS (p = 0.02), patellar score (p = 0.01), AKSS-Knee Score (p = 0.004), range of motion (ROM, p < 0.0001) and WOMAC Score (p = 0.0003) indicated that circumpatellarelectrocautery improved clinical outcomes compared with non-electrocautery. The results indicate that circumferential electrocautery of the patella does not significantly improve AKP compared with non-electrocautery techniques but that circumferential electrocautery significantly improves patients' knee function after surgery. Therefore, we believe that circumferential electrocautery is beneficial to the outcome of primary TKR surgery without patellar replacement.

  1. Circumferential electrocautery of the patella in primary total knee replacement without patellar replacement: a meta-analysis and systematic review

    NASA Astrophysics Data System (ADS)

    Fan, Lihong; Ge, Zhaogang; Zhang, Chen; Li, Jia; Yu, Zefeng; Dang, Xiaoqian; Wang, Kunzheng

    2015-03-01

    The purpose of this meta-analysis and systematic review was to identify and assess whether circumferential electrocautery is useful for improving outcomes after primary total knee replacement(TKR). We searched MEDLINE, EMBASE, PubMed, SpringerLink, Web of Knowledge, OVID CINAHL, OVID EBM and Google Scholar and included articles published through January 2014. A total of 6 articles met the inclusion criteria. Of the 776 cases included in the analysis, 388 cases involved patellar denervation, and 388 cases were designated as the control group. The meta-analysis revealed no significant difference in the incidence of anterior knee pain (AKP, p = 0.18) or in the visual analogue scale score (VAS, p = 0.23) between the two groups. In addition, AKSS Function Score indicated no significant difference between the two groups (p = 0.28). However, the OKS (p = 0.02), patellar score (p = 0.01), AKSS-Knee Score (p = 0.004), range of motion (ROM, p < 0.0001) and WOMAC Score (p = 0.0003) indicated that circumpatellarelectrocautery improved clinical outcomes compared with non-electrocautery. The results indicate that circumferential electrocautery of the patella does not significantly improve AKP compared with non-electrocautery techniques but that circumferential electrocautery significantly improves patients' knee function after surgery. Therefore, we believe that circumferential electrocautery is beneficial to the outcome of primary TKR surgery without patellar replacement.

  2. Achieving Consensus on Total Joint Replacement Trial Outcome Reporting Using the OMERACT Filter: Endorsement of the Final Core Domain Set for Total Hip and Total Knee Replacement Trials for Endstage Arthritis.

    PubMed

    Singh, Jasvinder A; Dowsey, Michelle M; Dohm, Michael; Goodman, Susan M; Leong, Amye L; Scholte Voshaar, Marieke M J H; Choong, Peter F

    2017-11-01

    Discussion and endorsement of the OMERACT total joint replacement (TJR) core domain set for total hip replacement (THR) and total knee replacement (TKR) for endstage arthritis; and next steps for selection of instruments. The OMERACT TJR working group met at the 2016 meeting at Whistler, British Columbia, Canada. We summarized the previous systematic reviews, the preliminary OMERACT TJR core domain set and results from previous surveys. We discussed preliminary core domains for TJR clinical trials, made modifications, and identified challenges with domain measurement. Working group participants (n = 26) reviewed, clarified, and endorsed each of the inner and middle circle domains and added a range of motion domain to the research agenda. TJR were limited to THR and TKR but included all endstage hip and knee arthritis refractory to medical treatment. Participants overwhelmingly endorsed identification and evaluation of top instruments mapping to the core domains (100%) and use of subscales of validated multidimensional instruments to measure core domains for the TJR clinical trial core measurement set (92%). An OMERACT core domain set for hip/knee TJR trials has been defined and we are selecting instruments to develop the TJR clinical trial core measurement set to serve as a common foundation for harmonizing measures in TJR clinical trials.

  3. Designing for Learning Conversations: How Parents Support Children's Science Learning within an Immersive Simulation

    ERIC Educational Resources Information Center

    Tscholl, Michael; Lindgren, Robb

    2016-01-01

    This research investigates the social learning affordances of a room-sized, immersive, and interactive augmented reality simulation environment designed to support children's understanding of basic physics concepts in a science center. Conversations between 97 parent-child pairs were analyzed in relation to categories of talk through which…

  4. Strengths-Based Advising Approaches: Benefits for First-Year Undergraduates

    ERIC Educational Resources Information Center

    Soria, Krista M.; Laumer, Nicole L.; Morrow, Dale J.; Marttinen, Garrett

    2017-01-01

    We explored the benefits of strengths-based academic advising approaches for first-year students (N = 1,228). We used propensity score matching techniques to create matched pairs of students who did and did not engage in strengths-based advising conversations with an advisor. First-year students who experienced strengths-based conversations had…

  5. Foreign Language Students' Conversational Negotiations in Different Task Environments

    ERIC Educational Resources Information Center

    Hardy, Ilonca M.; Moore, Joyce L.

    2004-01-01

    This study examined the effect of structural and content characteristics of language tasks on foreign language learners' conversational negotiations. In a 2x2 Greco-Latin square design, degree of structural support of language tasks, students' degree of familiarity with German video segments, and task order were varied. Twenty-eight pairs of…

  6. Selective photooxidation of hydrocarbons in zeolites by oxygen

    DOEpatents

    Frei, Heinz; Blatter, Fritz; Sun, Hai

    1998-01-01

    A selective photooxidation process for the conversion of hydrocarbon molecules to partially oxygenated derivatives, which comprises the steps of adsorbing a hydrocarbon and oxygen onto a dehydrated zeolite support matrix to form a hydrocarbon-oxygen contact pair, and subsequently exposing the hydrocarbon-oxygen contact pair to visible light, thereby forming a partially oxygenated derivative.

  7. Evaluation of coal-related model compounds using a tandem mass spectrometry.

    PubMed

    Li, Guo-Sheng; Dong, Xueming; Fan, Xing; You, Chun-Yan; Wu, Ge; Zhao, Yun-Peng; Lu, Yao; Wei, Xian-Yong; Ma, Feng-Yun

    2018-05-08

    Gas chromotography/mass spectrometry (GC/MS) is a routine and basic instrumental method for the analysis of complex coal conversion products in chemical industry. To further enhance practical potentials of GC/MS in chemical industry, a tandem MS method for the selection of ion pair applied in monitoring coal conversions was established by using GC/quadrupole time-of-flight MS (GC/Q-TOF MS). The corresponding fragmentation pathways were explored and suitable ion pairs were screened. Fourteen coal-related model compounds (CRMCs) were analyzed using a GC/Q-TOF MS with different collision induced dissociation (CID) energies (5-20 eV). The fragmentation pathways can offer a better understanding of chemical bond breaking, hydrogen transfer, rearrangement reactions and elimination of neutral fragments for CRMCs during the CID process. The precursor ions of aromatic hydrocarbons without alkyl chain were hard to fragment with a CID energy of 20 eV. But aromatic hydrocarbons with branched chains were prone to fragment via the loss of alkyl chains and further fragmented through ring-open reactions. Compared to C alk -C ar bond, C ar -C ar bond was hard to fragment duo to its high bond dissociation energy. The existence of heteroatoms facilitated fragmentation that was conducive to screening ion pair. The CID technique of GC/Q-TOF MS will contribute to the studies on the organic composition of coals and building monitoring methods for coal conversions via fragmentation and ion pair selection. This article is protected by copyright. All rights reserved.

  8. NIR tracking assists sports medicine in junior basketball training

    NASA Astrophysics Data System (ADS)

    Paeglis, Roberts; Bluss, Kristaps; Rudzitis, Andris; Spunde, Andris; Brice, Tamara; Nitiss, Edgars

    2011-07-01

    We recorded eye movements of eight elite junior basketball players. We hypothesized that a more stable gaze is correlated to a better shot rate. Upon preliminary testing we invited male juniors whose eyes could be reliably tracked in a game situation. To these ends, we used a head-mounted video-based eye tracker. The participants had no record of ocular or other health issues. No significant differences were found between shots made with and without the tracker cap, Paired samples t-test yielded p= .130 for the far and p=..900 > .050 for the middle range shots. The players made 40 shots from common far and middle range locations, 5 and 4 meters respectively for aged 14 years As expected, a statistical correlation was found between gaze fixation (in milliseconds) for the far and middle range shot rates, r=.782, p=.03. Notably, juniors who fixated longer before a shot had a more stable fixation or a lower gaze dispersion (in tracker's screen pixels), r=-.786, p=.02. This finding was augmented by the observation that the gaze dispersion while aiming at the basket was less (i.e., gaze more stable) in those who were more likely to score. We derived a regression equation linking fixation duration to shot success. We advocate infra-red eye tracking as a means to monitor player selection and training success.

  9. The Impact of Mutation and Gene Conversion on the Local Diversification of Antigen Genes in African Trypanosomes

    PubMed Central

    Gjini, Erida; Haydon, Daniel T.; Barry, J. David; Cobbold, Christina A.

    2012-01-01

    Patterns of genetic diversity in parasite antigen gene families hold important information about their potential to generate antigenic variation within and between hosts. The evolution of such gene families is typically driven by gene duplication, followed by point mutation and gene conversion. There is great interest in estimating the rates of these processes from molecular sequences for understanding the evolution of the pathogen and its significance for infection processes. In this study, a series of models are constructed to investigate hypotheses about the nucleotide diversity patterns between closely related gene sequences from the antigen gene archive of the African trypanosome, the protozoan parasite causative of human sleeping sickness in Equatorial Africa. We use a hidden Markov model approach to identify two scales of diversification: clustering of sequence mismatches, a putative indicator of gene conversion events with other lower-identity donor genes in the archive, and at a sparser scale, isolated mismatches, likely arising from independent point mutations. In addition to quantifying the respective probabilities of occurrence of these two processes, our approach yields estimates for the gene conversion tract length distribution and the average diversity contributed locally by conversion events. Model fitting is conducted using a Bayesian framework. We find that diversifying gene conversion events with lower-identity partners occur at least five times less frequently than point mutations on variant surface glycoprotein (VSG) pairs, and the average imported conversion tract is between 14 and 25 nucleotides long. However, because of the high diversity introduced by gene conversion, the two processes have almost equal impact on the per-nucleotide rate of sequence diversification between VSG subfamily members. We are able to disentangle the most likely locations of point mutations and conversions on each aligned gene pair. PMID:22735079

  10. Retrofit Weight-Loss Outcomes at 6, 12, and 24 Months and Characteristics of 12-Month High Performers: A Retrospective Analysis.

    PubMed

    Painter, Stefanie; Ditsch, Gary; Ahmed, Rezwan; Hanson, Nicholas Buck; Kachin, Kevin; Berger, Jan

    2016-08-22

    Obesity is the leading cause of preventable death costing the health care system billions of dollars. Combining self-monitoring technology with personalized behavior change strategies results in clinically significant weight loss. However, there is a lack of real-world outcomes in commercial weight-loss program research. Retrofit is a personalized weight management and disease-prevention solution. This study aimed to report Retrofit's weight-loss outcomes at 6, 12, and 24 months and characterize behaviors, age, and sex of high-performing participants who achieved weight loss of 10% or greater at 12 months. A retrospective analysis was performed from 2011 to 2014 using 2720 participants enrolled in a Retrofit weight-loss program. Participants had a starting body mass index (BMI) of >25 kg/m² and were at least 18 years of age. Weight measurements were assessed at 6, 12, and 24 months in the program to evaluate change in body weight, BMI, and percentage of participants who achieved 5% or greater weight loss. A secondary analysis characterized high-performing participants who lost ≥10% of their starting weight (n=238). Characterized behaviors were evaluated, including self-monitoring through weigh-ins, number of days wearing an activity tracker, daily step count average, and engagement through coaching conversations via Web-based messages, and number of coaching sessions attended. Average weight loss at 6 months was -5.55% for male and -4.86% for female participants. Male and female participants had an average weight loss of -6.28% and -5.37% at 12 months, respectively. Average weight loss at 24 months was -5.03% and -3.15% for males and females, respectively. Behaviors of high-performing participants were assessed at 12 months. Number of weigh-ins were greater in high-performing male (197.3 times vs 165.4 times, P=.001) and female participants (222 times vs 167 times, P<.001) compared with remaining participants. Total activity tracker days and average steps per day were greater in high-performing females (304.7 vs 266.6 days, P<.001; 8380.9 vs 7059.7 steps, P<.001, respectively) and males (297.1 vs 255.3 days, P<.001; 9099.3 vs 8251.4 steps, P=.008, respectively). High-performing female participants had significantly more coaching conversations via Web-based messages than remaining female participants (341.4 vs 301.1, P=.03), as well as more days with at least one such electronic message (118 vs 108 days, P=.03). High-performing male participants displayed similar behavior. Participants on the Retrofit program lost an average of -5.21% at 6 months, -5.83% at 12 months, and -4.09% at 24 months. High-performing participants show greater adherence to self-monitoring behaviors of weighing in, number of days wearing an activity tracker, and average number of steps per day. Female high performers have higher coaching engagement through conversation days and total number of coaching conversations.

  11. Liquid-assisted grinding and ion pairing regulates percentage conversion and diastereoselectivity of the Wittig reaction under mechanochemical conditions.

    PubMed

    Denlinger, Kendra Leahy; Ortiz-Trankina, Lianna; Carr, Preston; Benson, Kingsley; Waddell, Daniel C; Mack, James

    2018-01-01

    Mechanochemistry is maturing as a discipline and continuing to grow, so it is important to continue understanding the rules governing the system. In a mechanochemical reaction, the reactants are added into a vessel along with one or more grinding balls and the vessel is shaken at high speeds to facilitate a chemical reaction. The dielectric constant of the solvent used in liquid-assisted grinding (LAG) and properly chosen counter-ion pairing increases the percentage conversion of stilbenes in a mechanochemical Wittig reaction. Utilizing stepwise addition/evaporation of ethanol in liquid-assisted grinding also allows for the tuning of the diastereoselectivity in the Wittig reaction.

  12. Clustering of cycloidal wave energy converters

    DOEpatents

    Siegel, Stefan G.

    2016-03-29

    A wave energy conversion system uses a pair of wave energy converters (WECs) on respective active mountings on a floating platform, so that the separation of the WECs from each other or from a central WEC can be actively adjusted according to the wavelength of incident waves. The adjustable separation facilitates operation of the system to cancel reactive forces, which may be generated during wave energy conversion. Modules on which such pairs of WECs are mounted can be assembled with one or more central WECs to form large clusters in which reactive forces and torques can be made to cancel. WECs of different sizes can be employed to facilitate cancelation of reactive forces and torques.

  13. Effects of conversation interference on annoyance due to aircraft noise

    NASA Technical Reports Server (NTRS)

    Key, K. F.; Powell, C. A.

    1980-01-01

    The annoyance and interference effects of aircraft flyover noise on face to face conversation were investigated. Twenty 5 minute sessions, each composed of three flyovers, were presented to each of 20 pairs of female subjects in a simulated living room. Flyovers varied in peak noise level (55-79 dB, A-weighted) and spectrum (low or high frequency components). Subjects engaged in conversation for 10 sessions and in reverie for the other 10 sessions, and completed subjective ratings following every session. Annoyance was affected by noise level, but was not significantly different for the two activities of reverie and conversation. A noise level of 77 db was found unacceptable for conversation by 50 percent of the subjects. Conversation interference was assessed by incidence of increased vocal effort and/or interruption of conversation during flyovers. Although conversation interference increased with noise level, the conversation interference measures did not improve prediction of individual annoyance judgments.

  14. Femtosecond Laser--Pumped Source of Entangled Photons for Quantum Cryptography Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, D.; Donaldson, W.; Sobolewski, R.

    2007-07-31

    We present an experimental setup for generation of entangled-photon pairs via spontaneous parametric down-conversion, based on the femtosecond-pulsed laser. Our entangled-photon source utilizes a 76-MHz-repetition-rate, 100-fs-pulse-width, mode-locked, ultrafast femtosecond laser, which can produce, on average, more photon pairs than a cw laser of an equal pump power. The resulting entangled pairs are counted by a pair of high-quantum-efficiency, single-photon, silicon avalanche photodiodes. Our apparatus is intended as an efficient source/receiver system for the quantum communications and quantum cryptography applications.

  15. Improved Usability of Locomotion Devices Using Human-Centric Taxonomy

    DTIC Science & Technology

    2009-03-01

    the muscle fibers to which they are attached. Our muscles work mainly in antagonistic pairs, with one muscle contracting and its antagonist...skeletal system by the muscles signifies a conversion of electrochemical energy into physical energy, and thus, constitutes the commencement of the...Function of antagonistic pairs in muscles ........................................... 22 Figure 10. Physical interaction between right leg and

  16. Bicruciate retaining

    PubMed Central

    2016-01-01

    Total knee replacement (TKR) is a procedure used to treat knee arthropathy. Patients’ dissatisfaction is still relevant (literature reports dissatisfaction rates as high as 40%). The anterior cruciate ligament is usually removed while performing a total knee arthroplasty, thus changing knee biomechanics. As patients’ mean age to surgery is decreasing, bicruciate retaining models, which preserve normal biomechanics, may be useful in increasing patients’ outcomes. Limited data concerning bicruciate retaining arthroplasty is available; although clinical results are encouraging, there are concerns regarding surgical exposure, anterior cruciate integrity evaluation, and implant fixation. PMID:27162778

  17. Interfacing a quantum dot with a spontaneous parametric down-conversion source

    NASA Astrophysics Data System (ADS)

    Huber, Tobias; Prilmüller, Maximilian; Sehner, Michael; Solomon, Glenn S.; Predojević, Ana; Weihs, Gregor

    2017-09-01

    Quantum networks require interfacing stationary and flying qubits. These flying qubits are usually nonclassical states of light. Here we consider two of the leading source technologies for nonclassical light, spontaneous parametric down-conversion and single semiconductor quantum dots. Down-conversion delivers high-grade entangled photon pairs, whereas quantum dots excel at producing single photons. We report on an experiment that joins these two technologies and investigates the conditions under which optimal interference between these dissimilar light sources may be achieved.

  18. Ultrasonic guided wave propagation across waveguide transitions: energy transfer and mode conversion.

    PubMed

    Puthillath, Padmakumar; Galan, Jose M; Ren, Baiyang; Lissenden, Cliff J; Rose, Joseph L

    2013-05-01

    Ultrasonic guided wave inspection of structures containing adhesively bonded joints requires an understanding of the interaction of guided waves with geometric and material discontinuities or transitions in the waveguide. Such interactions result in mode conversion with energy being partitioned among the reflected and transmitted modes. The step transition between an aluminum layer and an aluminum-adhesive-aluminum multi-layer waveguide is analyzed as a model structure. Dispersion analysis enables assessment of (i) synchronism through dispersion curve overlap and (ii) wavestructure correlation. Mode-pairs in the multi-layer waveguide are defined relative to a prescribed mode in a single layer as being synchronized and having nearly perfect wavestructure matching. Only a limited number of mode-pairs exist, and each has a unique frequency range. A hybrid model based on semi-analytical finite elements and the normal mode expansion is implemented to assess mode conversion at a step transition in a waveguide. The model results indicate that synchronism and wavestructure matching is associated with energy transfer through the step transition, and that the energy of an incident wave mode in a single layer is transmitted almost entirely to the associated mode-pair, where one exists. This analysis guides the selection of incident modes that convert into transmitted modes and improve adhesive joint inspection with ultrasonic guided waves.

  19. Photon up-conversion production in Tb{sup 3+}–Yb{sup 3+} co-doped CaF{sub 2} phosphors prepared by combustion synthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rakov, Nikifor, E-mail: nikifor.gomez@univasf.edu.br; Guimarães, Renato B.; Maciel, Glauco S., E-mail: glauco@if.uff.br

    2016-02-15

    Graphical abstract: Up-conversion luminescence from Tb{sup 3+} obtained by energy transfer from Yb{sup 3+} pairs in CaF{sub 2} powder prepared by combustion synthesis. - Highlights: • Calcium fluoride (CaF{sub 2}) powders were prepared by combustion synthesis. • Rare-earth ions doped in this material were found in interstitial sites. • Cooperative up-conversion was observed in Tb{sup 3+}:Yb{sup 3+}:CaF{sub 2} powder. • Energy transfer between Tb{sup 3+} and pairs of Yb{sup 3+} was analyzed using rate equations. - Abstract: Calcium fluoride (CaF{sub 2}) crystalline powders were successfully prepared by the combustion synthesis method. The powder material containing luminescent rare-earth ions, more specificallymore » terbium (Tb{sup 3+}) and ytterbium (Yb{sup 3+}), was studied by X-ray diffraction, scanning electronic microscopy and optical spectroscopy. These ions are allocated in charge compensated interstitial positions of tetragonal (C{sub 4v}) and trigonal (C{sub 3v}) symmetry sites of the cubic (O{sub h}) CaF{sub 2} lattice. Up-conversion (UC) luminescence in Tb{sup 3+} was achieved using a low power diode laser operating at 975 nm. Tb{sup 3+} is insensitive to near-infrared radiation but UC can be achieved via energy transfer from pairs of Yb{sup 3+} ions to Tb{sup 3+} ions. The UC luminescence dynamics of Tb{sup 3+} was used to study the energy transfer mechanism.« less

  20. Thermodynamics and kinetics of Na+/K+-formate ion pairs association in polarizable water: A molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Nguyen, Phuong T. M.; Nguyen, Van T.; Annapureddy, Harsha V. R.; Dang, Liem X.; Do, D. D.

    2012-12-01

    To enhance our understanding of ion specific activity in biological systems, the potential of mean force approach was utilized to study solvent effects on the interactions between two alkali cations (Na+ and K+) with a formate anion in water. A very complex free energy landscape was observed, much more so than alkali-halide ion pairs. Furthermore, a stronger binding between the Na+-formate pair was found in comparison to the K+-formate pair in water, which is in agreement with experimental and theoretical studies [1-4]. The kinetics of ion-pair inter-conversions was studied using the transition rate theory, along with a number of theoretical approaches such as the Kramers and Grote-Hynes theories. These kinetic results were used to predict solvent effects on dynamical features of ion-pair association, in which we have found that the dynamics of K+-formate pairs is faster than Na+-formate pairs.

  1. Learner Agency and Non-Native Speaker Identity in Pedagogical Lingua Franca Conversations: Insights from Intercultural Telecollaboration in Foreign Language Education

    ERIC Educational Resources Information Center

    Kohn, Kurt; Hoffstaedter, Petra

    2017-01-01

    This article discusses insights gained from a case study on telecollaboration for intercultural communication in foreign language school contexts. Focus was on non-native English and German lingua franca conversations between pairs of students (aged 14-16, B1 level) from schools in France, Germany, the Netherlands and Spain. Telecollaboration…

  2. Understanding Task-in-Process through the Lens of Laughter: Activity Designs, Instructional Materials, Learner Orientations, and Interpersonal Relationships

    ERIC Educational Resources Information Center

    Hasegawa, Atsushi

    2018-01-01

    Using the framework of conversation analysis, this study investigated the interactional workings of laughter in task-based interactions. The analysis was drawn from 160 cases of pair work interactions, collected in 2nd-semester Japanese-as-a-foreign-language classrooms. The pair work activities examined in this study are mostly grammar-focused,…

  3. GEANT4 simulation of a scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers

    NASA Astrophysics Data System (ADS)

    Clarkson, A.; Hamilton, D. J.; Hoek, M.; Ireland, D. G.; Johnstone, J. R.; Kaiser, R.; Keri, T.; Lumsden, S.; Mahon, D. F.; McKinnon, B.; Murray, M.; Nutbeam-Tuffs, S.; Shearer, C.; Staines, C.; Yang, G.; Zimmerman, C.

    2014-05-01

    Cosmic-ray muons are highly penetrative charged particles that are observed at the sea level with a flux of approximately one per square centimetre per minute. They interact with matter primarily through Coulomb scattering, which is exploited in the field of muon tomography to image shielded objects in a wide range of applications. In this paper, simulation studies are presented that assess the feasibility of a scintillating-fibre tracker system for use in the identification and characterisation of nuclear materials stored within industrial legacy waste containers. A system consisting of a pair of tracking modules above and a pair below the volume to be assayed is simulated within the GEANT4 framework using a range of potential fibre pitches and module separations. Each module comprises two orthogonal planes of fibres that allow the reconstruction of the initial and Coulomb-scattered muon trajectories. A likelihood-based image reconstruction algorithm has been developed that allows the container content to be determined with respect to the scattering density λ, a parameter which is related to the atomic number Z of the scattering material. Images reconstructed from this simulation are presented for a range of anticipated scenarios that highlight the expected image resolution and the potential of this system for the identification of high-Z materials within a shielded, concrete-filled container. First results from a constructed prototype system are presented in comparison with those from a detailed simulation. Excellent agreement between experimental data and simulation is observed showing clear discrimination between the different materials assayed throughout.

  4. Gendered race: are infants' face preferences guided by intersectionality of sex and race?

    PubMed

    Kim, Hojin I; Johnson, Kerri L; Johnson, Scott P

    2015-01-01

    People occupy multiple social categories simultaneously (e.g., a White female), and this complex intersectionality affects fundamental aspects of social perception. Here, we examined the possibility that infant face processing may be susceptible to effects of intersectionality of sex and race. Three- and 10-month-old infants were shown a series of computer-generated face pairs (5 s each) that differed according to sex (Female or Male) or race (Asian, Black, or White). All possible combinations of face pairs were tested, and preferences were recorded with an eye tracker. Infants showed preferences for more feminine faces only when they were White, but we found no evidence that White or Asian faces were preferred even though they are relatively more feminized. These findings challenge the notions that infants' social categories are processed independently of one another and that infants' preferences for sex or race can be explained from mere exposure.

  5. Gendered race: are infants’ face preferences guided by intersectionality of sex and race?

    PubMed Central

    Kim, Hojin I.; Johnson, Kerri L.; Johnson, Scott P.

    2015-01-01

    People occupy multiple social categories simultaneously (e.g., a White female), and this complex intersectionality affects fundamental aspects of social perception. Here, we examined the possibility that infant face processing may be susceptible to effects of intersectionality of sex and race. Three- and 10-month-old infants were shown a series of computer-generated face pairs (5 s each) that differed according to sex (Female or Male) or race (Asian, Black, or White). All possible combinations of face pairs were tested, and preferences were recorded with an eye tracker. Infants showed preferences for more feminine faces only when they were White, but we found no evidence that White or Asian faces were preferred even though they are relatively more feminized. These findings challenge the notions that infants’ social categories are processed independently of one another and that infants’ preferences for sex or race can be explained from mere exposure. PMID:26388823

  6. Dual optical mechanical position tracker

    NASA Astrophysics Data System (ADS)

    Everett, S. L., Jr.

    1985-06-01

    This patent application describes an apparatus for retaining control of moving carriage impact dot matrix print heads when subjected to strong external forces such as shock and/or vibration. Position and direction of carriage movement is provided by a photo emitter-sensor assembly and a slotted timing wheel or disc having a plurality of equally spaced slots whose slot width is equal to the slot separation. The slot width is sufficient to frame a pair of side-by-side emitters which operate in conjunction with a pair of side-by-side sensors on the other side of the timing wheel. The order or sequence in which the sensors receive photo energy from their respective emitters indicates the direction of rotation of the timing wheel while simultaneous reception of photo energy by the side-by-side sensors provides an indication of valid rest position of the carriage drive motor.

  7. Is adapted measured resection superior to gap-balancing in determining femoral component rotation in total knee replacement?

    PubMed

    Luyckx, T; Peeters, T; Vandenneucker, H; Victor, J; Bellemans, J

    2012-09-01

    Obtaining a balanced flexion gap with correct femoral component rotation is one of the prerequisites for a successful outcome after total knee replacement (TKR). Different techniques for achieving this have been described. In this study we prospectively compared gap-balancing versus measured resection in terms of reliability and accuracy for femoral component rotation in 96 primary TKRs performed in 96 patients using the Journey system. In 48 patients (18 men and 30 women) with a mean age of 65 years (45 to 85) a tensor device was used to determine rotation. In the second group of 48 patients (14 men and 34 women) with a mean age of 64 years (41 to 86), an 'adapted' measured resection technique was used, taking into account the native rotational geometry of the femur as measured on a pre-operative CT scan. Both groups systematically reproduced a similar external rotation of the femoral component relative to the surgical transepicondylar axis: 2.4° (SD 2.5) in the gap-balancing group and 1.7° (SD 2.1) in the measured resection group (p = 0.134). Both gap-balancing and adapted measured resection techniques proved equally reliable and accurate in determining femoral component rotation after TKR. There was a tendency towards more external rotation in the gap-balancing group, but this difference was not statistically significant (p = 0.134). The number of outliers for our 'adapted' measured resection technique was much lower than reported in the literature.

  8. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study.

    PubMed

    Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar

    2017-01-01

    Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.

  9. Fractography and oxidative analysis of gamma inert sterilized posterior-stabilized tibial insert post fractures: report of two cases.

    PubMed

    Ansari, Farzana; Chang, Jennifer; Huddleston, James; Van Citters, Douglas; Ries, Michael; Pruitt, Lisa

    2013-12-01

    Highly crosslinked ultra-high molecular weight polyethylene (UHMWPE) has shown success in reducing wear in hip arthroplasty but there remains skepticism about its use in Total Knee Replacement (TKR) inserts that are known to experience fatigue loading and higher local cyclic contact stresses. Two Legacy Posterior-Stabilized (LPS) Zimmer NexGen tibial implants sterilized by gamma irradiation in an inert environment with posts that fractured in vivo were analyzed. Failure mechanisms were determined using optical and scanning electron microscopy along with oxidative analysis via Fourier Transform Infra-Red (FTIR) spectroscopy. Micrographs of one retrieval revealed fatigue crack initiation on opposite sides of the post and quasi-brittle micromechanisms of crack propagation. FTIR of this retrieval revealed no oxidation. The fracture surface image of the second retrieval indicated a brittle fracture process and FTIR revealed oxidation in the explant. These two cases suggest that crosslinking of UHMWPE as a manufacturing process or sterilization method in conjunction with designs that incorporate high stress concentrations, such as the tibial post, may reduce material strength. Moreover, free radicals generated from ionizing radiation can render the polymer susceptible to oxidative embrittlement. Our findings suggest that tibial post fractures may be the results of in vivo oxidation and low level crosslinking. These and previous reports of fractured crosslinked UHMWPE devices implores caution when used with high stress concentrations, particularly when considering the potential for in vivo oxidation in TKR. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Stair negotiation as a rehabilitation intervention for enhancing recovery following total hip and knee replacement surgery.

    PubMed

    Gavin, James P; Immins, Tikki; Wainwright, Thomas

    2017-05-01

    Total hip replacement (THR) and total knee replacement (TKR) are common orthopaedic procedures. However, an optimal programme for post-operative rehabilitation has yet to be established. Stair negotiation is a challenging, habitual task, regularly used as a post-operative functional outcome measure; yet as a physical rehabilitation intervention it appears to be rarely used. The review purpose was to investigate the effectiveness of stair climbing as a rehabilitation intervention for THR and TKR patients. MEDLINE, PsycINFO, Science Citation Index, CINAHL, SPORTDiscus and the Cochrane Database of Systematic Reviews were searched. The systematic review targeted studies using stair negotiation as a rehabilitation intervention. Randomised and non-randomised controlled trials, pilot studies, and case studies were included; systematic reviews and meta-analyses were excluded. Of 650 articles identified, ten studies were eligible for review. A predefined data table to extract information from selected studies was used. Of the ten identified reports, two prehabilitation and eight rehabilitation studies included stair negotiation exercises as part of multi-modal physical interventions. Outcome measures were classified as: functional self-reported, perceptual, psychological and those relating to quality of life. Studies were methodologically heterogeneous and typically lacked adequate control groups. It was not possible to determine the impact of stair negotiation exercise on the positive outcomes of interventions. Stair negotiation warrants further investigation as a rehabilitation activity. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  11. Cemented tibial component fixation performs better than cementless fixation: a randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years.

    PubMed

    Carlsson, Ake; Björkman, Anders; Besjakov, Jack; Onsten, Ingemar

    2005-06-01

    The question whether the tibial component of a total knee arthroplasty should be fixed to bone with or without bone cement has not yet been definitely answered. We studied movements between the tibial component and bone by radiostereometry (RSA) in total knee replacement (TKR) for 3 different types of fixation: cemented fixation (C-F), uncemented porous fixation (UC-F) and uncemented porous hydroxyapatite fixation (UCHA-F). 116 patients with osteoarthrosis, who had 146 TKRs, were included in 2 randomized series. The first series included 86 unilateral TKRs stratified into 1 of the 3 types of fixation. The second series included 30 patients who had simultaneous bilateral TKR surgery, and who were stratified into 3 subgroups of pairwise comparisons of the 3 types of fixation. After 5 years 2 knees had been revised, neither of which were due to loosening. 1 UCHA-F knee in the unilateral series showed a large and continuous migration and a poor clinical result, and is a pending failure. The C-F knees rotated and migrated less than UC-F and UCHA-F knees over 5 years. UCHA-F migrated less than UC-F after 1 year. Cementing of the tibial component offers more stable bone-implant contact for 5 years compared to uncemented fixation. When using uncemented components, however, there is evidence that augmenting a porous surface with hydroxyapatite may mean less motion between implant and bone after the initial postoperative year.

  12. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study

    PubMed Central

    Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar

    2017-01-01

    Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148

  13. Analgesia after total knee replacement: local infiltration versus epidural combined with a femoral nerve blockade: a prospective, randomised pragmatic trial.

    PubMed

    Yadeau, J T; Goytizolo, E A; Padgett, D E; Liu, S S; Mayman, D J; Ranawat, A S; Rade, M C; Westrich, G H

    2013-05-01

    In a randomised controlled pragmatic trial we investigated whether local infiltration analgesia would result in earlier readiness for discharge from hospital after total knee replacement (TKR) than patient-controlled epidural analgesia (PCEA) plus femoral nerve block. A total of 45 patients with a mean age of 65 years (49 to 81) received a local infiltration with a peri-articular injection of bupivacaine, morphine and methylprednisolone, as well as adjuvant analgesics. In 45 PCEA+femoral nerve blockade patients with a mean age of 67 years (50 to 84), analgesia included a bupivacaine nerve block, bupivacaine/hydromorphone PCEA, and adjuvant analgesics. The mean time until ready for discharge was 3.2 days (1 to 14) in the local infiltration group and 3.2 days (1.8 to 7.0) in the PCEA+femoral nerve blockade group. The mean pain scores for patients receiving local infiltration were higher when walking (p = 0.0084), but there were no statistically significant differences at rest. The mean opioid consumption was higher in those receiving local infiltration. The choice between these two analgesic pathways should not be made on the basis of time to discharge after surgery. Most secondary outcomes were similar, but PCEA+femoral nerve blockade patients had lower pain scores when walking and during continuous passive movement. If PCEA+femoral nerve blockade is not readily available, local infiltration provides similar length of stay and similar pain scores at rest following TKR.

  14. Analgesia after total knee replacement: local infiltration versus epidural combined with a femoral nerve blockade. A prospective, randomised pragmatic trial

    PubMed Central

    Goytizolo, Enrique A.; Padgett, Douglas E.; Liu, Spencer S.; Mayman, David J.; Ranawat, Amar S.; Rade, Matthew C.; Westrich, Geoffrey H.

    2014-01-01

    In a randomised controlled pragmatic trial we investigated whether local infiltration analgesia would result in earlier readiness for discharge from hospital after total knee replacement (TKR) than patient-controlled epidural analgesia (PCEA) plus femoral nerve block. A total of 45 patients with a mean age of 65 years (49 to 81) received a local infiltration with a peri-articular injection of bupivacaine, morphine, and methylprednisolone, as well as adjuvant analgesics. In 45 PCEA+femoral nerve blockade patients with a mean age of 67 years (50 to 84), analgesia included a bupivacaine nerve block, bupivacaine/hydromorphone PCEA, and adjuvant analgesics. The mean time until ready for discharge was 3.2 days (1 to 14) in the local infiltration group and 3.2 days (1.8 to 7.0) in the PCEA+femoral nerve blockade group. The mean pain scores for patients receiving local infiltration were higher when walking (p = 0.0084), but there were no statistically significant differences at rest. The mean opioid consumption was higher in those receiving local infiltration. The choice between these two analgesic pathways should not be made on the basis of time to discharge after surgery. Most secondary outcomes were similar, but PCEA+femoral nerve blockade patients had lower pain scores when walking and during continuous passive movement. If PCEA+femoral nerve blockade is not readily available, local infiltration provides similar length of stay and similar pain scores at rest following TKR. PMID:23632672

  15. Neurobiological Basis of Individual Variation in Stimulus-Reward Learning.

    PubMed

    Flagel, Shelly B; Robinson, Terry E

    2017-02-01

    Cues in the environment can guide behavior in adaptive ways, leading one towards valuable resources such as food, water, or a potential mate. However, cues in the environment may also serve as powerful motivators that lead to maladaptive patterns of behavior, such as addiction. Importantly, and central to this article, there is considerable individual variation in the extent to which reward cues gain motivational control over behavior. Here we describe an animal model that captures this individual variation, allowing us to better understand the psychological and neurobiological processes that contribute to cue-evoked behaviors. When a discrete cue is paired with a food reward in a Pavlovian manner it acquires greater control over motivated behavior in some rats ("sign-trackers, STs) than in others ("goal-trackers", GTs). We review studies that have exploited this animal model to parse the neurobiological mechanisms involved in learning associations between stimuli vs. those involved in attributing incentive salience to those same stimuli. The latter seems to be dependent on dopamine and subcortical circuits, whereas the former may engage more cortical "top-down" mechanisms.

  16. Flexible Coordination of Stationary and Mobile Conversations with Gaze: Resource Allocation among Multiple Joint Activities

    PubMed Central

    Mayor, Eric; Bangerter, Adrian

    2016-01-01

    Gaze is instrumental in coordinating face-to-face social interactions. But little is known about gaze use when social interactions co-occur with other joint activities. We investigated the case of walking while talking. We assessed how gaze gets allocated among various targets in mobile conversations, whether allocation of gaze to other targets affects conversational coordination, and whether reduced availability of gaze for conversational coordination affects conversational performance and content. In an experimental study, pairs were videotaped in four conditions of mobility (standing still, talking while walking along a straight-line itinerary, talking while walking along a complex itinerary, or walking along a complex itinerary with no conversational task). Gaze to partners was substantially reduced in mobile conversations, but gaze was still used to coordinate conversation via displays of mutual orientation, and conversational performance and content was not different between stationary and mobile conditions. Results expand the phenomena of multitasking to joint activities. PMID:27822189

  17. 1.5-μm band polarization entangled photon-pair source with variable Bell states.

    PubMed

    Arahira, Shin; Kishimoto, Tadashi; Murai, Hitoshi

    2012-04-23

    In this paper we report a polarization-entangled photon-pair source in a 1.5-μm band which can generate arbitrary entangled states including four maximum entangled states (Bell states) by using cascaded optical second nonlinearities (second-harmonic generation and the following spontaneous parametric down conversion) in a periodically poled LiNbO(3) (PPLN) ridge-waveguide device. Exchange among the Bell states was achieved by using an optical phase bias compensator (OPBC) in a Sagnac loop interferometer and a half-wave plate outside the loop for polarization conversion. Quantitative evaluation was made on the performance of the photon-pair source through the experiments of two-photon interferences, quantum state tomography, and test of violation of Bell inequality. We observed high visibilities of 96%, fidelities of 97%, and 2.71 of the S parameter in inequality of Clauser, Horne, Shimony, and Holt (CHSH). The experimental values, including peak coincidence counts in the two-photon interference (approximately 170 counts per second), remained almost unchanged in despite of the exchange among the Bell states. They were also in good agreement with the theoretical assumption from the mean number of the photon-pairs under the test (0.04 per pulse). More detailed experimental studies on the dependence of the mean number of the photon-pairs revealed that the quantum states were well understood as the Werner state. © 2012 Optical Society of America

  18. Is e+e- pair emission important in the determination of the 3He+4He S factor?

    NASA Astrophysics Data System (ADS)

    Snover, K. A.; Hurd, A. E.

    2003-05-01

    We show that the cross section for direct E0 pair emission is related to the cross section for direct E2 photon emission, and is a negligible contribution to the total capture cross section for 3He+4He→7Be. E0 resonance emission, E1 pair emission, and internal conversion are also negligible. Thus there cannot be significant contributions to the 3He+4He→7Be capture cross section at low energies from electromagnetic emission processes other than single photon emission.

  19. Effect of the Molecular Nature of Mutation on the Efficiency of Intrachromosomal Gene Conversion in Mouse Cells

    PubMed Central

    Letsou, Anthea; Liskay, R. Michael

    1987-01-01

    With the intent of further exploring the nature of gene conversion in mammalian cells, we systematically addressed the effects of the molecular nature of mutation on the efficiency of intrachromosomal gene conversion in cultured mouse cells. Comparison of conversion rates revealed that all mutations studied were suitable substrates for gene conversion; however, we observed that the rates at which different mutations converted to wild-type could differ by two orders of magnitude. Differences in conversion rates were correlated with the molecular nature of the mutations. In general, rates of conversion decreased with increasing size of the molecular lesions. In comparisons of conversion rates for single base pair insertions and deletions we detected a genotype-directed path for conversion, by which an insertion was converted to wild-type three to four times more efficiently than was a deletion which maps to the same site. The data are discussed in relation to current theories of gene conversion, and are consistent with the idea that gene conversion in mammalian cells can result from repair of heteroduplex DNA (hDNA) intermediates. PMID:2828159

  20. Twofold spin-triplet pairing states and tunneling conductance in ferromagnet/ferromagnet/iron pnictide superconductor heterojunctions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, X.; Tao, Y.C., E-mail: yctao88@163.com; Dong, Z.C.

    By applying an extended eight-component Bogoliubov–de Gennes equation, we study theoretically the tunneling conductance in clean ferromagnet/ferromagnet/iron pnictide superconductor (FM/FM/iron-based SC) heterojunctions. Under the condition of noncollinear magnetizations, twofold novel Andreev reflections exist due to the existence of two bands in the SC, in which the incident electron and the two Andreev-reflected holes, belonging to the same spin subband, form twofold spin-triplet pairing states near the FM/iron-based SC interface. It is shown that the conversions of the conductance not only between the zero-bias peak and valley at zero energy but also between the peaks and dips at two gap energiesmore » are strongly dependent on both the interband coupling strength in the SC and the spin polarization in the FM. The qualitative differences from tunneling into a conventional s-wave SC are also presented, which may help with experimentally probing and identifying the antiphase s-wave pairing symmetry in the iron-based SC. -- Highlights: •An eight-component Bogoliubov–de Gennes (BDG) equation. •Twofold novel ARs and twofold usual ARs. •Conversions of conductance between the zero-bias peak and valley at zero energy. •Conversions of conductance between peaks and dips at two gap energies. •The importance of the interband coupling strength in the SC.« less

  1. Multi-client quantum key distribution using wavelength division multiplexing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grice, Warren P; Bennink, Ryan S; Earl, Dennis Duncan

    Quantum Key Distribution (QKD) exploits the rules of quantum mechanics to generate and securely distribute a random sequence of bits to two spatially separated clients. Typically a QKD system can support only a single pair of clients at a time, and so a separate quantum link is required for every pair of users. We overcome this limitation with the design and characterization of a multi-client entangled-photon QKD system with the capacity for up to 100 clients simultaneously. The time-bin entangled QKD system includes a broadband down-conversion source with two unique features that enable the multi-user capability. First, the photons aremore » emitted across a very large portion of the telecom spectrum. Second, and more importantly, the photons are strongly correlated in their energy degree of freedom. Using standard wavelength division multiplexing (WDM) hardware, the photons can be routed to different parties on a quantum communication network, while the strong spectral correlations ensure that each client is linked only to the client receiving the conjugate wavelength. In this way, a single down-conversion source can support dozens of channels simultaneously--and to the extent that the WDM hardware can send different spectral channels to different clients, the system can support multiple client pairings. We will describe the design and characterization of the down-conversion source, as well as the client stations, which must be tunable across the emission spectrum.« less

  2. Retrofit Weight-Loss Outcomes at 6, 12, and 24 Months and Characteristics of 12-Month High Performers: A Retrospective Analysis

    PubMed Central

    Hanson, Nicholas Buck; Kachin, Kevin; Berger, Jan

    2016-01-01

    Background Obesity is the leading cause of preventable death costing the health care system billions of dollars. Combining self-monitoring technology with personalized behavior change strategies results in clinically significant weight loss. However, there is a lack of real-world outcomes in commercial weight-loss program research. Objective Retrofit is a personalized weight management and disease-prevention solution. This study aimed to report Retrofit’s weight-loss outcomes at 6, 12, and 24 months and characterize behaviors, age, and sex of high-performing participants who achieved weight loss of 10% or greater at 12 months. Methods A retrospective analysis was performed from 2011 to 2014 using 2720 participants enrolled in a Retrofit weight-loss program. Participants had a starting body mass index (BMI) of >25 kg/m² and were at least 18 years of age. Weight measurements were assessed at 6, 12, and 24 months in the program to evaluate change in body weight, BMI, and percentage of participants who achieved 5% or greater weight loss. A secondary analysis characterized high-performing participants who lost ≥10% of their starting weight (n=238). Characterized behaviors were evaluated, including self-monitoring through weigh-ins, number of days wearing an activity tracker, daily step count average, and engagement through coaching conversations via Web-based messages, and number of coaching sessions attended. Results Average weight loss at 6 months was −5.55% for male and −4.86% for female participants. Male and female participants had an average weight loss of −6.28% and −5.37% at 12 months, respectively. Average weight loss at 24 months was −5.03% and −3.15% for males and females, respectively. Behaviors of high-performing participants were assessed at 12 months. Number of weigh-ins were greater in high-performing male (197.3 times vs 165.4 times, P=.001) and female participants (222 times vs 167 times, P<.001) compared with remaining participants. Total activity tracker days and average steps per day were greater in high-performing females (304.7 vs 266.6 days, P<.001; 8380.9 vs 7059.7 steps, P<.001, respectively) and males (297.1 vs 255.3 days, P<.001; 9099.3 vs 8251.4 steps, P=.008, respectively). High-performing female participants had significantly more coaching conversations via Web-based messages than remaining female participants (341.4 vs 301.1, P=.03), as well as more days with at least one such electronic message (118 vs 108 days, P=.03). High-performing male participants displayed similar behavior. Conclusions Participants on the Retrofit program lost an average of −5.21% at 6 months, −5.83% at 12 months, and −4.09% at 24 months. High-performing participants show greater adherence to self-monitoring behaviors of weighing in, number of days wearing an activity tracker, and average number of steps per day. Female high performers have higher coaching engagement through conversation days and total number of coaching conversations. PMID:27549134

  3. Experimental extraction of an entangled photon pair from two identically decohered pairs.

    PubMed

    Yamamoto, Takashi; Koashi, Masato; Ozdemir, Sahin Kaya; Imoto, Nobuyuki

    2003-01-23

    Entanglement is considered to be one of the most important resources in quantum information processing schemes, including teleportation, dense coding and entanglement-based quantum key distribution. Because entanglement cannot be generated by classical communication between distant parties, distribution of entangled particles between them is necessary. During the distribution process, entanglement between the particles is degraded by the decoherence and dissipation processes that result from unavoidable coupling with the environment. Entanglement distillation and concentration schemes are therefore needed to extract pairs with a higher degree of entanglement from these less-entangled pairs; this is accomplished using local operations and classical communication. Here we report an experimental demonstration of extraction of a polarization-entangled photon pair from two decohered photon pairs. Two polarization-entangled photon pairs are generated by spontaneous parametric down-conversion and then distributed through a channel that induces identical phase fluctuations to both pairs; this ensures that no entanglement is available as long as each pair is manipulated individually. Then, through collective local operations and classical communication we extract from the two decohered pairs a photon pair that is observed to be polarization-entangled.

  4. Fitbit Charge HR Wireless Heart Rate Monitor: Validation Study Conducted Under Free-Living Conditions.

    PubMed

    Gorny, Alexander Wilhelm; Liew, Seaw Jia; Tan, Chuen Seng; Müller-Riemenschneider, Falk

    2017-10-20

    Many modern smart watches and activity trackers feature an optical sensor that estimates the wearer's heart rate. Recent studies have evaluated the performance of these consumer devices in the laboratory. The objective of our study was to examine the accuracy and sensitivity of a common wrist-worn tracker device in measuring heart rates and detecting 1-min bouts of moderate to vigorous physical activity (MVPA) under free-living conditions. Ten healthy volunteers were recruited from a large university in Singapore to participate in a limited field test, followed by a month of continuous data collection. During the field test, each participant would wear one Fitbit Charge HR activity tracker and one Polar H6 heart rate monitor. Fitbit measures were accessed at 1-min intervals, while Polar readings were available for 10-s intervals. We derived intraclass correlation coefficients (ICCs) for individual participants comparing heart rate estimates. We applied Centers for Disease Control and Prevention heart rate zone cut-offs to ascertain the sensitivity and specificity of Fitbit in identifying 1-min epochs falling into MVPA heart rate zone. We collected paired heart rate data for 2509 1-min epochs in 10 individuals under free-living conditions of 3 to 6 hours. The overall ICC comparing 1-min Fitbit measures with average 10-s Polar H6 measures for the same epoch was .83 (95% CI .63-.91). On average, the Fitbit tracker underestimated heart rate measures by -5.96 bpm (standard error, SE=0.18). At the low intensity heart rate zone, the underestimate was smaller at -4.22 bpm (SE=0.15). This underestimate grew to -16.2 bpm (SE=0.74) in the MVPA heart rate zone. Fitbit devices detected 52.9% (192/363) of MVPA heart rate zone epochs correctly. Positive and negative predictive values were 86.1% (192/223) and 92.52% (2115/2286), respectively. During subsequent 1 month of continuous data collection (270 person-days), only 3.9% of 1-min epochs could be categorized as MVPA according to heart rate zones. This measure was affected by decreasing wear time and adherence over the period of follow-up. Under free-living conditions, Fitbit trackers are affected by significant systematic errors. Improvements in tracker accuracy and sensitivity when measuring MVPA are required before they can be considered for use in the context of exercise prescription to promote better health. ©Alexander Wilhelm Gorny, Seaw Jia Liew, Chuen Seng Tan, Falk Müller-Riemenschneider. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 20.10.2017.

  5. Efficiency of Synchrotron Radiation from Rotation-powered Pulsars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kisaka, Shota; Tanaka, Shuta J., E-mail: kisaka@phys.aoyama.ac.jp, E-mail: sjtanaka@center.konan-u.ac.jp

    2017-03-01

    Synchrotron radiation is widely considered to be the origin of the pulsed non-thermal emissions from rotation-powered pulsars in optical and X-ray bands. In this paper, we study the synchrotron radiation emitted by the created electron and positron pairs in the pulsar magnetosphere to constrain the energy conversion efficiency from the Poynting flux to the particle energy flux. We model two pair creation processes, two-photon collision, which efficiently works in young γ -ray pulsars (≲10{sup 6} year), and magnetic pair creation, which is the dominant process to supply pairs in old pulsars (≳10{sup 6} year). Using the analytical model, we derivemore » the maximum synchrotron luminosity as a function of the energy conversion efficiency. From the comparison with observations, we find that the energy conversion efficiency to the accelerated particles should be an order of unity in the magnetosphere, even though we make a number of the optimistic assumptions to enlarge the synchrotron luminosity. In order to explain the luminosity of the non-thermal X-ray/optical emission from pulsars with low spin-down luminosity L {sub sd} ≲ 10{sup 34} erg s{sup −1}, non-dipole magnetic field components should be dominant at the emission region. For the γ -ray pulsars with L {sub sd} ≲ 10{sup 35} erg s{sup −1}, observed γ -ray to X-ray and optical flux ratios are much higher than the flux ratio between curvature and the synchrotron radiations. We discuss some possibilities such as the coexistence of multiple accelerators in the magnetosphere as suggested from the recent numerical simulation results. The obtained maximum luminosity would be useful to select observational targets in X-ray and optical bands.« less

  6. Early Verb Learning: How Do Children Learn How to Compare Events?

    PubMed Central

    Childers, Jane B.; Parrish, Rebecca; Olson, Christina V.; Burch, Clare; Fung, Gavin; McIntyre, Kevin

    2015-01-01

    An important problem verb learners must solve is how to extend verbs. Children could use cross-situational information to guide their extensions, however comparing events is difficult. Two studies test whether children benefit from initially seeing a pair of similar events (‘progressive alignment’) while learning new verbs, and whether this influence changes with age. In Study 1, 2 ½- and 3 ½-year-old children participated in an interactive task. Children who saw a pair of similar events and then varied events were able to extend verbs at test, differing from a control group; children who saw two pairs of varied events did not differ from the control group. In Study 2, events were presented on a monitor. Following the initial pair of events that varied by condition, a Tobii x120 eye tracker recorded 2 ½-, 3 ½- and 4 ½-year-olds’ fixations to specific elements of events (AOIs) during the second pair of events, which were the same across conditions. After seeing the pair of events that were highly similar, 2 ½-year-olds showed significantly longer fixation durations to agents and to affected objects as compared to the all varied condition. At test, 3 ½-year-olds were able to extend the verb, but only in the progressive alignment condition. These results are important because they show children’s visual attention to relevant elements in dynamic events is influenced by their prior comparison experience, and they show that young children benefit from seeing similar events as they learn to compare events to each other. PMID:27092030

  7. Simultaneous parametric generation and up-conversion of entangled optical images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saygin, M. Yu., E-mail: mihasyu@gmail.com; Chirkin, A. S., E-mail: aschirkin@rambler.r

    A quantum theory of parametric amplification and frequency conversion of an optical image in coupled nonlinear optical processes that include one parametric amplification process at high-frequency pumping and two up-conversion processes in the same pump field is developed. The field momentum operator that takes into account the diffraction and group velocities of the waves is used to derive the quantum equations related to the spatial dynamics of the images during the interaction. An optical scheme for the amplification and conversion of a close image is considered. The mean photon number density and signal-to-noise ratio are calculated in the fixed-pump-field approximationmore » for images at various frequencies. It has been established that the signal-to-noise ratio decreases with increasing interaction length in the amplified image and increases in the images at the generated frequencies, tending to asymptotic values for all interacting waves. The variance of the difference of the numbers of photons is calculated for various pairs of frequencies. The quantum entanglement of the optical images formed in a high-frequency pump field is shown to be converted to higher frequencies during the generation of sum frequencies. Thus, two pairs of entangled optical images are produced in the process considered.« less

  8. Design of high-brightness TEM00-mode solar-pumped laser for renewable material processing

    NASA Astrophysics Data System (ADS)

    Liang, D.; Almeida, J.

    2014-08-01

    The conversion of sunlight into laser light by direct solar pumping is of ever-increasing importance because broadband, temporally constant, sunlight is converted into laser light, which can be a source of narrowband, collimated, rapidly pulsed, radiation with the possibility of obtaining extremely high brightness and intensity. Nonlinear processes, such as harmonic generation, might be used to obtain broad wavelength coverage, including the ultraviolet wavelengths, where the solar flux is very weak. The direct excitation of large lasers by sunlight offers the prospect of a drastic reduction in the cost of coherent optical radiation for high average power materials processing. This renewable laser has a large potential for many applications such as high-temperature materials processing, renewable magnesium-hydrogen energy cycle and so on. We propose here a scalable TEM00 mode solar laser pumping scheme, which is composed of four firststage 1.13 m diameter Fresnel lenses with its respective folding mirrors mounted on a two-axis automatic solar tracker. Concentrated solar power at the four focal spots of these Fresnel lenses are focused individually along a common 3.5 mm diameter, 70 mm length Nd:YAG rod via four pairs of second-stage fused-silica spherical lenses and third-stage 2D-CPCs (Compound Parabolic Concentrator), sitting just above the laser rod which is also double-pass pumped by four V-shaped pumping cavities. Distilled water cools both the rod and the concentrators. 15.4 W TEM00 solar laser power is numerically calculated, corresponding to 6.7 times enhancement in laser beam brightness.

  9. Overview of Multi-Kilowatt Free-Piston Stirling Power Conversion Research at Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Geng, Steven M.; Mason, Lee S.; Dyson, Rodger W.; Penswick, L. Barry

    2008-01-01

    As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors and a pair of commercially available pressure wave generators (which will be plumbed together to create a high power Stirling linear alternator test rig) have been procured for in-house testing at Glenn Research Center (GRC). Delivery of both the Stirling convertors and the linear alternator test rig is expected by October 2007. The 1 kW class free-piston Stirling convertors will be tested at GRC to map and verify performance. The convertors will later be modified to operate with a NaK liquid metal pumped loop for thermal energy input. The high power linear alternator test rig will be used to map and verify high power Stirling linear alternator performance and to develop power management and distribution (PMAD) methods and techniques. This paper provides an overview of the multi-kilowatt free-piston Stirling power conversion work being performed at GRC.

  10. Overview of Multi-kilowatt Free-Piston Stirling Power Conversion Research at GRC

    NASA Technical Reports Server (NTRS)

    Geng, Steven M.; Mason, Lee S.; Dyson, Rodger W.; Penswick, L. Barry

    2008-01-01

    As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors and a pair of commercially available pressure wave generators (which will be plumbed together to create a high power Stirling linear alternator test rig) have been procured for in-house testing at Glenn Research Center. Delivery of both the Stirling convertors and the linear alternator test rig is expected by October, 2007. The 1 kW class free-piston Stirling convertors will be tested at GRC to map and verify performance. The convertors will later be modified to operate with a NaK liquid metal pumped loop for thermal energy input. The high power linear alternator test rig will be used to map and verify high power Stirling linear alternator performance and to develop power management and distribution (PMAD) methods and techniques. This paper provides an overview of the multi-kilowatt free-piston Stirling power conversion work being performed at GRC.

  11. Overview of Multi-Kilowatt Free-Piston Stirling Power Conversion Research at GRC

    NASA Astrophysics Data System (ADS)

    Geng, Steven M.; Mason, Lee S.; Dyson, Rodger W.; Penswick, L. Barry

    2008-01-01

    As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors and a pair of commercially available pressure wave generators (which will be plumbed together to create a high power Stirling linear alternator test rig) have been procured for in-house testing at Glenn Research Center. Delivery of both the Stirling convertors and the linear alternator test rig is expected by October, 2007. The 1 kW class free-piston Stirling convertors will be tested at GRC to map and verify performance. The convertors will later be modified to operate with a NaK liquid metal pumped loop for thermal energy input. The high power linear alternator test rig will be used to map and verify high power Stirling linear alternator performance and to develop power management and distribution (PMAD) methods and techniques. This paper provides an overview of the multi-kilowatt free-piston Stirling power conversion work being performed at GRC.

  12. Tracking the coherent generation of polaron pairs in conjugated polymers

    NASA Astrophysics Data System (ADS)

    de Sio, Antonietta; Troiani, Filippo; Maiuri, Margherita; Réhault, Julien; Sommer, Ephraim; Lim, James; Huelga, Susana F.; Plenio, Martin B.; Rozzi, Carlo Andrea; Cerullo, Giulio; Molinari, Elisa; Lienau, Christoph

    2016-12-01

    The optical excitation of organic semiconductors not only generates charge-neutral electron-hole pairs (excitons), but also charge-separated polaron pairs with high yield. The microscopic mechanisms underlying this charge separation have been debated for many years. Here we use ultrafast two-dimensional electronic spectroscopy to study the dynamics of polaron pair formation in a prototypical polymer thin film on a sub-20-fs time scale. We observe multi-period peak oscillations persisting for up to about 1 ps as distinct signatures of vibronic quantum coherence at room temperature. The measured two-dimensional spectra show pronounced peak splittings revealing that the elementary optical excitations of this polymer are hybridized exciton-polaron-pairs, strongly coupled to a dominant underdamped vibrational mode. Coherent vibronic coupling induces ultrafast polaron pair formation, accelerates the charge separation dynamics and makes it insensitive to disorder. These findings open up new perspectives for tailoring light-to-current conversion in organic materials.

  13. Electromagnetic cascades in pulsars

    NASA Technical Reports Server (NTRS)

    Daugherty, J. K.; Harding, A. K.

    1981-01-01

    The development of pair photon cascades initiated by high energy electrons above a pulsar polar cap is simulated numerically. The calculation uses the energy of the primary electron, the magnetic field strength, and the period of rotation as parameters and follows the curvature radiation emitted by the primary, the conversion of this radiation e(+) - e(-) pairs in the intense fields, and the quantized synchrotron radiation by the secondary pairs. A recursive technique allows the tracing of an indefinite number of generations using a Monte Carlo method. Gamma ray and pair spectra are calculated for cascades in different parts of the polar cap and with different acceleration models. It is found that synchrotron radiation from secondary pairs makes an important contribution to the gamma ray spectrum above 25 MeV, and that the final gamma ray and pair spectra are insensitive to the height of the accelerating region, as long as the acceleration of the primary electrons is not limited by radiation reaction.

  14. Equivalences between nonuniform exponential dichotomy and admissibility

    NASA Astrophysics Data System (ADS)

    Zhou, Linfeng; Lu, Kening; Zhang, Weinian

    2017-01-01

    Relationship between exponential dichotomies and admissibility of function classes is a significant problem for hyperbolic dynamical systems. It was proved that a nonuniform exponential dichotomy implies several admissible pairs of function classes and conversely some admissible pairs were found to imply a nonuniform exponential dichotomy. In this paper we find an appropriate admissible pair of classes of Lyapunov bounded functions which is equivalent to the existence of nonuniform exponential dichotomy on half-lines R± separately, on both half-lines R± simultaneously, and on the whole line R. Additionally, the maximal admissibility is proved in the case on both half-lines R± simultaneously.

  15. The Advanced Pair Telescope (APT) Mission Concept

    NASA Technical Reports Server (NTRS)

    Hunter, Stanley; Buckley, James H.

    2008-01-01

    We present a mission concept for the Advanced Pair Telescope (APT), a high-energy gamma-ray instrument with an order of magnitude improvement in sensitivity, 6 sr field of view, and angular resolution a factor of 3-10 times that of GLAST. With its very wide instantaneous field-of-view and large effective area, this instrument would be capable of detecting GRBs at very large redshifts, would enable a very high resolution study of SNRs and PWN, and could provide hour-scale temporal resolution of transients from many AGN and galactic sources. The APT instrument will consist of a Xe time-projection-chamber tracker that bridges the energy regime between Compton scattering and pair production and will provide an unprecedented improvement in angular resolution; a thick scintillating-fiber trackerlcalorimeter that will provide sensitivity and energy resolution to higher energies and will possess a factor of 10 improvement in geometric factor over GLAST; and an anticoincidence detector using scintillator-tiles to reject charged particles. After the anticipated 10-years of GLAST operation , the APT instrument would provide continued coverage of the critial high-energy gamma-ray band (between 30 MeV to 100 GeV), providing an essential component of broad-band multiwavelength studies of the high-energy universe.

  16. Influence of posterior condylar offset on knee flexion after cruciate-sacrificing mobile-bearing total knee replacement: a prospective analysis of 410 consecutive cases.

    PubMed

    Bauer, T; Biau, D; Colmar, M; Poux, X; Hardy, P; Lortat-Jacob, A

    2010-12-01

    The range of motion of the knee joint after Total Knee Replacement (TKR) is a factor of great importance that determines the postoperative function of patients. Much enthusiasm has been recently directed towards the posterior condylar offset with some authors reporting increasing postoperative knee flexion with increasing posterior condylar offset and others who did not report any significant association. Patients undergoing primary total knee replacement were included in a prospective multicentre study and the effect of the posterior condylar offset on the postoperative knee flexion was assessed after adjusting for known influential factors. All knees were implanted by three senior orthopedist surgeons with the same cemented cruciate-sacrificing mobile-bearing implant and with identical surgical technique. Clinical data, active knee flexion and posterior condylar offset were recorded preoperatively and postoperatively at a minimal one year follow-up for all patients. Univariate and multivariate linear models were fitted to select independent predictors of the postoperative knee flexion. Four hundred and ten consecutive total knee replacements (379 patients) were included in the study. The mean preoperative knee flexion was 112°. The mean condylar offset was 28.3mm preoperatively and 29.4mm postoperatively. The mean postoperative knee flexion was 108°. No correlation was found between the posterior condylar offset or the tibial slope and the postoperative knee flexion. The most significant predictive factor for postoperative flexion after posterior-stabilized TKR without PCL retention was the preoperative range of flexion, with a linear effect. Copyright © 2009 Elsevier B.V. All rights reserved.

  17. Association of Psychosocial Factors With Physical Activity and Function After Total Knee Replacement: An Exploratory Study.

    PubMed

    Dominick, Gregory M; Zeni, Joseph A; White, Daniel K

    2016-09-01

    To examine the association between self-efficacy, social support, and fear of movement with physical activity and function at baseline and after 12 weeks of physical therapy. Nonrandomized cohort study, repeated-measures design. Outpatient rehabilitation clinic within the general community. Adults (N=49) undergoing outpatient physical therapy for total knee replacement (TKR). Not applicable. Self-efficacy for exercise (SEE), fear of movement, leisure-time physical activity (LTPA), 6-minute walk test (6MWT), and Knee Outcome Survey-Activities of Daily Living Scale (KOS-ADLS) were assessed at baseline and 12 weeks. Mean functional change scores significantly increased at 12 weeks for the 6MWT (95% confidence interval [CI], 42.3-106.2), KOS-ADLS (95% CI, 12.7-23.3), and LTPA (95% CI, 6.5-26.1). Self-efficacy and fear of movement were not significantly associated with function at baseline or 12 weeks. Participants with lower SEE had 6 fewer metabolic equivalents per week of improvement in LTPA than those with high self-efficacy (95% CI, -27.9 to 14.8), and those with high fear of movement had 26.1m less improvement in the 6MWT than those with low fear of movement (95% CI, -42.2 to 94.5). Most participants reported having no family or peer support for exercise. Physical therapy for TKR improves physical function and self-reported physical activity. High fear of movement and low SEE may be associated with less improvement in physical activity and function over time. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. An experimental demonstration of a new type of proton computed tomography using a novel silicon tracking detector.

    PubMed

    Taylor, J T; Poludniowski, G; Price, T; Waltham, C; Allport, P P; Casse, G L; Esposito, M; Evans, P M; Green, S; Manger, S; Manolopoulos, S; Nieto-Camero, J; Parker, D J; Symons, J; Allinson, N M

    2016-11-01

    Radiography and tomography using proton beams promise benefit to image guidance and treatment planning for proton therapy. A novel proton tracking detector is described and experimental demonstrations at a therapy facility are reported. A new type of proton CT reconstructing relative "scattering power" rather than "stopping power" is also demonstrated. Notably, this new type of imaging does not require the measurement of the residual energies of the protons. A large area, silicon microstrip tracker with high spatial and temporal resolution has been developed by the Proton Radiotherapy Verification and Dosimetry Applications consortium and commissioned using beams of protons at iThemba LABS, Medical Radiation Department, South Africa. The tracker comprises twelve planes of silicon developed using technology from high energy physics with each plane having an active area of ∼10 × 10 cm segmented into 2048 microstrips. The tracker is organized into four separate units each containing three detectors at 60° to one another creating an x-u-v coordinate system. Pairs of tracking units are used to reconstruct vertices for protons entering and exiting a phantom containing tissue equivalent inserts. By measuring the position and direction of each proton before and after the phantom, the nonlinear path for each proton through an object can be reconstructed. Experimental results are reported for tracking the path of protons with initial energies of 125 and 191 MeV. A spherical phantom of 75 mm diameter was imaged by positioning it between the entrance and exit detectors of the tracker. Positions and directions of individual protons were used to create angular distributions and 2D fluence maps of the beam. These results were acquired for 36 equally spaced projections spanning 180°, allowing, for the first time, an experimental CT image based upon the relative scattering power of protons to be reconstructed. Successful tracking of protons through a thick target (phantom) has demonstrated that the tracker discussed in this paper can provide the precise directional information needed to perform proton radiography and tomography. When synchronized with a range telescope, this could enable the reconstruction of proton CT images of stopping power. Furthermore, by measuring the deflection of many protons through a phantom, it was demonstrated that it is possible to reconstruct a new kind of CT image (scattering power) based upon this tracking information alone.

  19. Disrupting reconsolidation: memory erasure or blunting of emotional/motivational value?

    PubMed

    Cogan, Elizabeth S; Shapses, Mark A; Robinson, Terry E; Tronson, Natalie C

    2018-05-03

    When memories are retrieved they become labile, and subject to alteration by a process known as reconsolidation. Disruption of memory reconsolidation decreases the performance of learned responses, which is often attributed to erasure of the memory; in the case of Pavlovian learning, to a loss of the association between a conditioned stimulus (CS) and unconditioned stimulus (US). However, an alternative interpretation is that disrupting reconsolidation does not erase memories, but blunts their emotional/motivational impact. It is difficult to parse the predictive vs. emotional/motivational value of CSs in non-human animals, but studies on variation in the form of conditioned responses (CRs) in a Pavlovian conditioned approach task suggest a way to do this. In this task a lever-CS paired with a food reward (US) acquires predictive value in all rats, but is attributed with emotional/motivational value to a greater extent in some rats (sign-trackers) than others (goal-trackers). We report that the post-retrieval administration of propranolol selectively attenuates a sign-tracking CR, and the associated neural activation of brain "motive circuits", while having no effect on conditioned orienting behavior in sign-trackers, or on goal-tracking CRs evoked by either a lever-CS or a tone-CS. We conclude that the disruption of reconsolidation by post-retrieval propranolol degrades the emotional/motivational impact of the CS, required for sign-tracking, but leaves the CS-US association intact. The possibility that post-retrieval interventions can reduce the emotional/motivational aspects of memories, without actually erasing them, has important implications for treating maladaptive memories that contribute to some psychiatric disorders.

  20. Novel insights into the mechanism of the ortho/para spin conversion of hydrogen pairs: implications for catalysis and interstellar water.

    PubMed

    Limbach, Hans-Heinrich; Buntkowsky, Gerd; Matthes, Jochen; Gründemann, Stefan; Pery, Tal; Walaszek, Bernadeta; Chaudret, Bruno

    2006-03-13

    The phenomenon of exchange coupling is taken into account in the description of the magnetic nuclear spin conversion between bound ortho- and para-dihydrogen. This conversion occurs without bond breaking, in contrast to the chemical spin conversion. It is shown that the exchange coupling needs to be reduced so that the corresponding exchange barrier can increase and the given magnetic interaction can effectively induce a spin conversion. The implications for related molecules such as water are discussed. For ice, a dipolar magnetic conversion and for liquid water a chemical conversion are predicted to occur within the millisecond timescale. It follows that a separation of water into its spin isomers, as proposed by Tikhonov and Volkov (Science 2002, 296, 2363), is not feasible. Nuclear spin temperatures of water vapor in comets, which are smaller than the gas-phase equilibrium temperatures, are proposed to be diagnostic for the temperature of the ice or the dust surface from which the water was released.

  1. Conversion of amino-acid sequence in proteins to classical music: search for auditory patterns

    PubMed Central

    2007-01-01

    We have converted genome-encoded protein sequences into musical notes to reveal auditory patterns without compromising musicality. We derived a reduced range of 13 base notes by pairing similar amino acids and distinguishing them using variations of three-note chords and codon distribution to dictate rhythm. The conversion will help make genomic coding sequences more approachable for the general public, young children, and vision-impaired scientists. PMID:17477882

  2. Diffusion affected magnetic field effect in exciplex fluorescence

    NASA Astrophysics Data System (ADS)

    Burshtein, Anatoly I.; Ivanov, Anatoly I.

    2014-07-01

    The fluorescence of the exciplex, 1[D+δA-δ], formed at contact of photoexcited acceptor 1A* with an electron donor 1D, is known to be very sensitive to an external magnetic field, reducing the spin conversion efficiency in the resulting geminate radical ion pair, 1, 3[D+…A-]. The relative increase of the exciplex fluorescence in the highest magnetic field compared to the lowest one, known as the magnetic field effect, crucially depends on the viscosity of the solvent. This phenomenon first studied experimentally is at first reproduced here theoretically. The magnetic field effect is shown to vanish in both limits of high and low solvent diffusivity reaching a maximum in between. It is also very sensitive to the solvent dielectric constant and to the exciplex and radical-ion pair conversion rates.

  3. Diffusion affected magnetic field effect in exciplex fluorescence.

    PubMed

    Burshtein, Anatoly I; Ivanov, Anatoly I

    2014-07-14

    The fluorescence of the exciplex, (1)[D(+δ)A(-δ)], formed at contact of photoexcited acceptor (1)A(*) with an electron donor (1)D, is known to be very sensitive to an external magnetic field, reducing the spin conversion efficiency in the resulting geminate radical ion pair, (1, 3)[D(+)…A(-)]. The relative increase of the exciplex fluorescence in the highest magnetic field compared to the lowest one, known as the magnetic field effect, crucially depends on the viscosity of the solvent. This phenomenon first studied experimentally is at first reproduced here theoretically. The magnetic field effect is shown to vanish in both limits of high and low solvent diffusivity reaching a maximum in between. It is also very sensitive to the solvent dielectric constant and to the exciplex and radical-ion pair conversion rates.

  4. Dosimetry of high-energy electron linac produced photoneutrons and the bremsstrahlung gamma-rays using TLD-500 and TLD-700 dosimeter pairs

    NASA Astrophysics Data System (ADS)

    Mukherjee, Bhaskar; Makowski, Dariusz; Simrock, Stefan

    2005-06-01

    The neutron and gamma doses are crucial to interpreting the radiation effects in microelectronic devices operating in a high-energy accelerator environment. This report highlights a method for an accurate estimation of photoneutron and the accompanying bremsstrahlung (gamma) doses produced by a 450 MeV electron linear accelerator (linac) operating in pulsed mode. The principle is based on the analysis of thermoluminescence glow-curves of TLD-500 (Aluminium Oxide) and TLD-700 (Lithium Fluoride) dosimeter pairs. The gamma and fast neutron response of the TLD-500 and TLD-700 dosimeter pairs were calibrated with a 60Co (gamma) and a 241Am-Be (α, n) neutron standard-source, respectively. The Kinetic Energy Released in Materials (kerma) conversion factor for photoneutrons was evaluated by folding the neutron kerma (dose) distribution in 7LiF (the main component of the TLD-700 dosimeter) with the energy spectra of the 241Am-Be (α, n) neutrons and electron accelerator produced photoneutrons. The neutron kerma conversion factors for 241Am-Be neutrons and photoneutrons were calculated to be 2.52×10 -3 and 1.37×10 -3 μGy/a.u. respectively. The bremsstrahlung (gamma) dose conversion factor was evaluated to be 7.32×10 -4 μGy/a.u. The above method has been successfully utilised to assess the photoneutron and bremsstrahlung doses from a 450 MeV electron linac operating at DESY Research Centre in Hamburg, Germany.

  5. Thirty-year results from a paired-catchment study of upland flowpath responses to forest cover conversion in northern Minnesota

    Treesearch

    Stephen Sebestyen; Randy Kolka

    2016-01-01

    Long-term studies on paired-research catchments have often showed periods of changes to water yields and peak stormflow after forest harvesting. Most studies have focused on wholecatchment or downstream responses. In contrast, few studies have ever been established to measure and investigate specific pathways of water routing through catchment soils or how sub-...

  6. Economic evaluation of major knee surgery with recombinant activated factor VII in hemophilia patients with high titer inhibitors and advanced knee arthropathy: exploratory results via literature-based modeling.

    PubMed

    Ballal, Rahul D; Botteman, Marc F; Foley, Isaac; Stephens, Jennifer M; Wilke, Caitlyn T; Joshi, Ashish V

    2008-03-01

    People with severe hemophilia suffer from frequent intra-articular hemorrhages, leading to pain, swelling, reduced flexion, and arthropathy. Elective orthopedic surgery using factor VIII (FVIII) replacement to prevent uncontrolled bleeding has been endorsed as an effective treatment option for patients with severe or advanced hemophilic arthropathy. These surgeries reduce pain, restore mobility and function, and reduce the frequency of recurrent joint bleeds. Unfortunately, some patients with hemophilia develop inhibitors to FVIII, which neutralize FVIII activity and render the use of even massive amounts of FVIII replacement ineffective and surgery very risky. For this reason, elective surgical procedures in high-titer inhibitor patients had largely been abandoned until the introduction of new agents, such as recombinant activated factor VII (rFVIIa, NovoSeven, Novo Nordisk A/S, Denmark). rFVIIa has been shown effective for prophylaxis during elective surgery and has therefore improved the feasibility of orthopedic surgery in hemophilia patients with high-titer inhibitors. The present research explored, from a modified US payer perspective, the direct economic and quality of life benefits of four different elective knee surgeries (total knee replacement [TKR], knee arthrodesis [KA], proximal tibial osteotomy, and distal femoral osteotomy) with rFVIIa coverage in hemophilia patients with high-titer inhibitors. An exploratory literature-based life-table model was developed to compare the direct medical costs and quality of life of two hypothetical cohorts of high-titer inhibitor patients with frequent bleeding episodes: one undergoing and the other not undergoing elective knee surgery. Knee surgery costs included perioperative rFVIIa costs, inpatient and rehabilitation care, and repeat procedures due to surgery failure, prosthesis loosening or deep infection. Based on efficacy studies, knee surgery was assumed to reduce mean annual bleeding episodes at the affected joint from 9.13 to 1.64. The cost of managing each bleeding episode was estimated at $15 298. Thus, by reducing bleeding episodes, surgery was expected to result in related cost offsets. All costs were expressed in 2006 US dollars. Surgery was also assumed to result in gains in quality of life by reducing pain and reducing bleeding episodes. The impact of pain reduction on quality of life and utility was estimated by simulating EQ-5D scores for a typical patient with and without knee surgery. Based on the model, average knee surgery costs are predicted to range from a low of $694 000 (for KA) to a high of $855 000 (for TKR). However, knee surgery is also expected to reduce the subsequent number of bleeding episodes and resultant costs, leading to long-term costs savings. Due to improvement in pain levels, surgical patients are expected to experience improvements in quality-adjusted life-years (QALYs). Thus, surgery appears to be the preferred strategy (i.e., saves costs and increases QALYs). Based on the assumptions used in the model, the initial cost of knee surgery was offset during the 8th and 10th years for KA and TKR, respectively, with intermediate break-even time for the other surgeries. As expected, cost savings and gains in QALYs increased over time, as well as the cost effective ness of knee surgery. Specifically, the cost per QALY with KA and TKR fell under $50 000/QALY during the 6th and 8th years, respectively, with intermediate time for the other surgeries. The present exploratory analysis is based on the long-term extrapolation of data from a small number of patients without inhibitors and short-term studies. It suggests that major knee surgery utilizing rFVIIa in hemophilia patients with inhibitors may be cost-effective on average, with expected cost savings apparent within a decade of knee surgery. The present exploratory results should be validated with real-world, longitudinal patient data.

  7. Fuzzy logic control of stand-alone photovoltaic system with battery storage

    NASA Astrophysics Data System (ADS)

    Lalouni, S.; Rekioua, D.; Rekioua, T.; Matagne, E.

    Photovoltaic energy has nowadays an increased importance in electrical power applications, since it is considered as an essentially inexhaustible and broadly available energy resource. However, the output power provided via the photovoltaic conversion process depends on solar irradiation and temperature. Therefore, to maximize the efficiency of the photovoltaic energy system, it is necessary to track the maximum power point of the PV array. The present paper proposes a maximum power point tracker (MPPT) method, based on fuzzy logic controller (FLC), applied to a stand-alone photovoltaic system. It uses a sampling measure of the PV array power and voltage then determines an optimal increment required to have the optimal operating voltage which permits maximum power tracking. This method carries high accuracy around the optimum point when compared to the conventional one. The stand-alone photovoltaic system used in this paper includes two bi-directional DC/DC converters and a lead-acid battery bank to overcome the scare periods. One converter works as an MPP tracker, while the other regulates the batteries state of charge and compensates the power deficit to provide a continuous delivery of energy to the load. The Obtained simulation results show the effectiveness of the proposed fuzzy logic controller.

  8. Study of the material of the ATLAS inner detector for Run 2 of the LHC

    DOE PAGES

    Aaboud, M.; Aad, G.; Abbott, B.; ...

    2017-12-07

    The ATLAS inner detector comprises three different sub-detectors: the pixel detector, the silicon strip tracker, and the transition-radiation drift-tube tracker. The Insertable B-Layer, a new innermost pixel layer, was installed during the shutdown period in 2014, together with modifications to the layout of the cables and support structures of the existing pixel detector. The material in the inner detector is studied with several methods, using a low-luminosity √s=13 TeV pp collision sample corresponding to around 2.0 nb -1 collected in 2015 with the ATLAS experiment at the LHC. In this paper, the material within the innermost barrel region is studiedmore » using reconstructed hadronic interaction and photon conversion vertices. For the forward rapidity region, the material is probed by a measurement of the efficiency with which single tracks reconstructed from pixel detector hits alone can be extended with hits on the track in the strip layers. The results of these studies have been taken into account in an improved description of the material in the ATLAS inner detector simulation, resulting in a reduction in the uncertainties associated with the charged-particle reconstruction efficiency determined from simulation.« less

  9. Study of the material of the ATLAS inner detector for Run 2 of the LHC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaboud, M.; Aad, G.; Abbott, B.

    The ATLAS inner detector comprises three different sub-detectors: the pixel detector, the silicon strip tracker, and the transition-radiation drift-tube tracker. The Insertable B-Layer, a new innermost pixel layer, was installed during the shutdown period in 2014, together with modifications to the layout of the cables and support structures of the existing pixel detector. The material in the inner detector is studied with several methods, using a low-luminosity √s=13 TeV pp collision sample corresponding to around 2.0 nb -1 collected in 2015 with the ATLAS experiment at the LHC. In this paper, the material within the innermost barrel region is studiedmore » using reconstructed hadronic interaction and photon conversion vertices. For the forward rapidity region, the material is probed by a measurement of the efficiency with which single tracks reconstructed from pixel detector hits alone can be extended with hits on the track in the strip layers. The results of these studies have been taken into account in an improved description of the material in the ATLAS inner detector simulation, resulting in a reduction in the uncertainties associated with the charged-particle reconstruction efficiency determined from simulation.« less

  10. Study of the material of the ATLAS inner detector for Run 2 of the LHC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaboud, M.; Aad, G.; Abbott, B.

    The ATLAS inner detector comprises three different sub-detectors: the pixel detector, the silicon strip tracker, and the transition-radiation drift-tube tracker. The Insertable B-Layer, a new innermost pixel layer, was installed during the shutdown period in 2014, together with modifications to the layout of the cables and support structures of the existing pixel detector. The material in the inner detector is studied with several methods, using a low-luminosity √s = 13 TeV pp collision sample corresponding to around 2.0 nb -1 collected in 2015 with the ATLAS experiment at the LHC. In this paper, the material within the innermost barrel regionmore » is studied using reconstructed hadronic interaction and photon conversion vertices. For the forward rapidity region, the material is probed by a measurement of the efficiency with which single tracks reconstructed from pixel detector hits alone can be extended with hits on the track in the strip layers. The results of these studies have been taken into account in an improved description of the material in the ATLAS inner detector simulation, resulting in a reduction in the uncertainties associated with the charged-particle reconstruction efficiency determined from simulation.« less

  11. Study of the material of the ATLAS inner detector for Run 2 of the LHC

    NASA Astrophysics Data System (ADS)

    Aaboud, M.; Aad, G.; Abbott, B.; Abdallah, J.; Abdinov, O.; Abeloos, B.; Abidi, S. H.; AbouZeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abreu, R.; Abulaiti, Y.; Acharya, B. S.; Adachi, S.; Adamczyk, L.; Adelman, J.; Adersberger, M.; Adye, T.; Affolder, A. A.; Agatonovic-Jovin, T.; Agheorghiesei, C.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akatsuka, S.; Akerstedt, H.; Åkesson, T. P. A.; Akilli, E.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albicocco, P.; Alconada Verzini, M. J.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Ali, B.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Alshehri, A. A.; Alstaty, M.; Alvarez Gonzalez, B.; Álvarez Piqueras, D.; Alviggi, M. G.; Amadio, B. T.; Amaral Coutinho, Y.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amorim, A.; Amoroso, S.; Amundsen, G.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Angerami, A.; Anisenkov, A. V.; Anjos, N.; Annovi, A.; Antel, C.; Antonelli, M.; Antonov, A.; Antrim, D. J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Arabidze, G.; Arai, Y.; Araque, J. P.; Araujo Ferraz, V.; Arce, A. T. H.; Ardell, R. E.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Arik, M.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Backhaus, M.; Bagnaia, P.; Bahrasemani, H.; Baines, J. T.; Bajic, M.; Baker, O. K.; Baldin, E. M.; Balek, P.; Balli, F.; Balunas, W. K.; Banas, E.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisits, M.-S.; Barkeloo, J. T.; Barklow, T.; Barlow, N.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska-Blenessy, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barranco Navarro, L.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Becker, K.; Becker, M.; Beckingham, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beermann, T. A.; Begalli, M.; Begel, M.; Behr, J. K.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Beltramello, O.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Bendtz, K.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez, J.; Benjamin, D. P.; Benoit, M.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernardi, G.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertolucci, F.; Bertram, I. A.; Bertsche, C.; Bertsche, D.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Betancourt, C.; Bethani, A.; Bethke, S.; Bevan, A. J.; Beyer, J.; Bianchi, R. M.; Biebel, O.; Biedermann, D.; Bielski, R.; Biesuz, N. V.; Biglietti, M.; Bilbao De Mendizabal, J.; Billoud, T. R. V.; Bilokon, H.; Bindi, M.; Bingul, A.; Bini, C.; Biondi, S.; Bisanz, T.; Bittrich, C.; Bjergaard, D. M.; Black, C. W.; Black, J. E.; Black, K. M.; Blair, R. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blue, A.; Blum, W.; Blumenschein, U.; Blunier, S.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boehler, M.; Boerner, D.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bokan, P.; Bold, T.; Boldyrev, A. S.; Bolz, A. E.; Bomben, M.; Bona, M.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Boscherini, D.; Bosman, M.; Bossio Sola, J. D.; Boudreau, J.; Bouffard, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J. E.; Breaden Madden, W. D.; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Briglin, D. L.; Bristow, T. M.; Britton, D.; Britzger, D.; Brochu, F. M.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brosamer, J.; Brost, E.; Broughton, J. H.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruni, A.; Bruni, G.; Bruni, L. S.; Brunt, BH; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burch, T. J.; Burckhart, H.; Burdin, S.; Burgard, C. D.; Burger, A. M.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Burr, J. T. P.; Busato, E.; Büscher, D.; Büscher, V.; Bussey, P.; Butler, J. M.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Cabrera Urbán, S.; Caforio, D.; Cairo, V. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Callea, G.; Caloba, L. P.; Calvente Lopez, S.; Calvet, D.; Calvet, S.; Calvet, T. P.; Camacho Toro, R.; Camarda, S.; Camarri, P.; Cameron, D.; Caminal Armadans, R.; Camincher, C.; Campana, S.; Campanelli, M.; Camplani, A.; Campoverde, A.; Canale, V.; Cano Bret, M.; Cantero, J.; Cao, T.; Capeans Garrido, M. D. M.; Caprini, I.; Caprini, M.; Capua, M.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carlson, B. T.; Carminati, L.; Carney, R. M. D.; Caron, S.; Carquin, E.; Carrá, S.; Carrillo-Montoya, G. D.; Carvalho, J.; Casadei, D.; Casado, M. P.; Casolino, M.; Casper, D. W.; Castelijn, R.; Castillo Gimenez, V.; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Celebi, E.; Ceradini, F.; Cerda Alberich, L.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, W. S.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chau, C. C.; Chavez Barajas, C. A.; Che, S.; Cheatham, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, H.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheplakov, A.; Cheremushkina, E.; Cherkaoui El Moursli, R.; Chernyatin, V.; Cheu, E.; Cheung, K.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chiu, Y. H.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Christodoulou, V.; Chromek-Burckhart, D.; Chu, M. C.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Ciftci, A. K.; Cinca, D.; Cindro, V.; Cioara, I. A.; Ciocca, C.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Citterio, M.; Ciubancan, M.; Clark, A.; Clark, B. L.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Colasurdo, L.; Cole, B.; Colijn, A. P.; Collot, J.; Colombo, T.; Conde Muiño, P.; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Constantinescu, S.; Conti, G.; Conventi, F.; Cooke, M.; Cooper-Sarkar, A. M.; Cormier, F.; Cormier, K. J. R.; Corradi, M.; Corriveau, F.; Cortes-Gonzalez, A.; Cortiana, G.; Costa, G.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Creager, R. A.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cribbs, W. A.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cueto, A.; Cuhadar Donszelmann, T.; Cukierman, A. R.; Cummings, J.; Curatolo, M.; Cúth, J.; Czirr, H.; Czodrowski, P.; D'amen, G.; D'Auria, S.; D'eramo, L.; D'Onofrio, M.; Da Cunha Sargedas De Sousa, M. J.; Da Via, C.; Dabrowski, W.; Dado, T.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Daneri, M. F.; Dang, N. P.; Daniells, A. C.; Dann, N. S.; Danninger, M.; Dano Hoffmann, M.; Dao, V.; Darbo, G.; Darmora, S.; Dassoulas, J.; Dattagupta, A.; Daubney, T.; Davey, W.; David, C.; Davidek, T.; Davies, M.; Davis, D. R.; Davison, P.; Dawe, E.; Dawson, I.; De, K.; de Asmundis, R.; De Benedetti, A.; De Castro, S.; De Cecco, S.; De Groot, N.; de Jong, P.; De la Torre, H.; De Lorenzi, F.; De Maria, A.; De Pedis, D.; De Salvo, A.; De Sanctis, U.; De Santo, A.; De Vasconcelos Corga, K.; De Vivie De Regie, J. B.; Dearnaley, W. J.; Debbe, R.; Debenedetti, C.; Dedovich, D. V.; Dehghanian, N.; Deigaard, I.; Del Gaudio, M.; Del Peso, J.; Del Prete, T.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Dell'Acqua, A.; Dell'Asta, L.; Dell'Orso, M.; Della Pietra, M.; della Volpe, D.; Delmastro, M.; Delporte, C.; Delsart, P. A.; DeMarco, D. A.; Demers, S.; Demichev, M.; Demilly, A.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Devesa, M. R.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; Di Bello, F. A.; Di Ciaccio, A.; Di Ciaccio, L.; Di Clemente, W. K.; Di Donato, C.; Di Girolamo, A.; Di Girolamo, B.; Di Micco, B.; Di Nardo, R.; Di Petrillo, K. F.; Di Simone, A.; Di Sipio, R.; Di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Diehl, E. B.; Dietrich, J.; Díez Cornell, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; do Vale, M. A. B.; Dobos, D.; Dobre, M.; Doglioni, C.; Dolejsi, J.; Dolezal, Z.; Donadelli, M.; Donati, S.; Dondero, P.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Dubreuil, A.; Duchovni, E.; Duckeck, G.; Ducourthial, A.; Ducu, O. A.; Duda, D.; Dudarev, A.; Dudder, A. Chr.; Duffield, E. M.; Duflot, L.; Dührssen, M.; Dumancic, M.; Dumitriu, A. E.; Duncan, A. K.; Dunford, M.; Duran Yildiz, H.; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Dyndal, M.; Dziedzic, B. S.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; El Kosseifi, R.; Ellajosyula, V.; Ellert, M.; Elles, S.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Endner, O. C.; Ennis, J. S.; Erdmann, J.; Ereditato, A.; Ernis, G.; Ernst, M.; Errede, S.; Escalier, M.; Escobar, C.; Esposito, B.; Estrada Pastor, O.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Ezzi, M.; Fabbri, F.; Fabbri, L.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Falla, R. J.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, C.; Farina, E. M.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Faucci Giannelli, M.; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, H.; Fenton, M. J.; Fenyuk, A. B.; Feremenga, L.; Fernandez Martinez, P.; Fernandez Perez, S.; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferreira de Lima, D. E.; Ferrer, A.; Ferrere, D.; Ferretti, C.; Fiedler, F.; Filipčič, A.; Filipuzzi, M.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Fischer, A.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, R. R. M.; Flick, T.; Flierl, B. M.; Flores Castillo, L. R.; Flowerdew, M. J.; Forcolin, G. T.; Formica, A.; Förster, F. A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Franchino, S.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Freund, B.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fusayasu, T.; Fuster, J.; Gabaldon, C.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Ganguly, S.; Gao, Y.; Gao, Y. S.; Garay Walls, F. M.; García, C.; García Navarro, J. E.; García Pascual, J. A.; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Gascon Bravo, A.; Gasnikova, K.; Gatti, C.; Gaudiello, A.; Gaudio, G.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gee, C. N. P.; Geisen, J.; Geisen, M.; Geisler, M. P.; Gellerstedt, K.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; Gentsos, C.; George, S.; Gerbaudo, D.; Gershon, A.; Geßner, G.; Ghasemi, S.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giannetti, P.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giokaris, N.; Giordani, M. P.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugni, D.; Giuli, F.; Giuliani, C.; Giulini, M.; Gjelsten, B. K.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gkountoumis, P.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Goncalves Gama, R.; Goncalves Pinto Firmino Da Costa, J.; Gonella, G.; Gonella, L.; Gongadze, A.; González de la Hoz, S.; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorelov, I.; Gorini, B.; Gorini, E.; Gorišek, A.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gottardo, C. A.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Gozani, E.; Graber, L.; Grabowska-Bold, I.; Gradin, P. O. J.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gravila, P. M.; Gray, C.; Gray, H. M.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Grummer, A.; Guan, L.; Guan, W.; Guenther, J.; Guescini, F.; Guest, D.; Gueta, O.; Gui, B.; Guido, E.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, W.; Guo, Y.; Gupta, R.; Gupta, S.; Gustavino, G.; Gutierrez, P.; Gutierrez Ortiz, N. G.; Gutschow, C.; Guyot, C.; Guzik, M. P.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Hageböck, S.; Hagihara, M.; Hakobyan, H.; Haleem, M.; Haley, J.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Hamnett, P. G.; Han, L.; Han, S.; Hanagaki, K.; Hanawa, K.; Hance, M.; Haney, B.; Hanke, P.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Hariri, F.; Harkusha, S.; Harrington, R. D.; Harrison, P. F.; Hartmann, N. M.; Hasegawa, M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havener, L. B.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hayakawa, D.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Head, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heidegger, K. K.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Held, A.; Hellman, S.; Helsens, C.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Henriques Correia, A. M.; Henrot-Versille, S.; Herbert, G. H.; Herde, H.; Herget, V.; Hernández Jiménez, Y.; Herr, H.; Herten, G.; Hertenberger, R.; Hervas, L.; Herwig, T. C.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Higashino, S.; Higón-Rodriguez, E.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hils, M.; Hinchliffe, I.; Hirose, M.; Hirschbuehl, D.; Hiti, B.; Hladik, O.; Hoad, X.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohn, D.; Holmes, T. R.; Homann, M.; Honda, S.; Honda, T.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Hostachy, J.-Y.; Hou, S.; Hoummada, A.; Howarth, J.; Hoya, J.; Hrabovsky, M.; Hrdinka, J.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, P. J.; Hsu, S.-C.; Hu, Q.; Hu, S.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Hughes, G.; Huhtinen, M.; Huo, P.; Huseynov, N.; Huston, J.; Huth, J.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ilic, N.; Introzzi, G.; Ioannou, P.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Isacson, M. F.; Ishijima, N.; Ishino, M.; Ishitsuka, M.; Issever, C.; Istin, S.; Ito, F.; Ponce, J. M. Iturbe; Iuppa, R.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, P.; Jacobs, R. M.; Jain, V.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansky, R.; Janssen, J.; Janus, M.; Janus, P. A.; Jarlskog, G.; Javadov, N.; Javůrek, T.; Javurkova, M.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jelinskas, A.; Jenni, P.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiang, Z.; Jiggins, S.; Jimenez Pena, J.; Jin, S.; Jinaru, A.; Jinnouchi, O.; Jivan, H.; Johansson, P.; Johns, K. A.; Johnson, C. A.; Johnson, W. J.; Jon-And, K.; Jones, R. W. L.; Jones, S. D.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Juste Rozas, A.; Köhler, M. K.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kaji, T.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanaya, N.; Kanjir, L.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kar, D.; Karakostas, K.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karpov, S. N.; Karpova, Z. M.; Karthik, K.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawade, K.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kay, E. F.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kempster, J. J.; Kendrick, J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khader, M.; Khalil-zada, F.; Khanov, A.; Kharlamov, A. G.; Kharlamova, T.; Khodinov, A.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kilby, C. R.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; Kirchmeier, D.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kitali, V.; Kiuchi, K.; Kivernyk, O.; Kladiva, E.; Klapdor-Kleingrothaus, T.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klingl, T.; Klioutchnikova, T.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Köhler, N. M.; Koi, T.; Kolb, M.; Koletsou, I.; Komar, A. A.; Komori, Y.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Kopeliansky, R.; Koperny, S.; Kopp, A. K.; Korcyl, K.; Kordas, K.; Korn, A.; Korol, A. A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Koulouris, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kourlitis, E.; Kouskoura, V.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozakai, C.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Krauss, D.; Kremer, J. A.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, M. C.; Kubota, T.; Kucuk, H.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kulinich, Y. P.; Kuna, M.; Kunigo, T.; Kupco, A.; Kupfer, T.; Kuprash, O.; Kurashige, H.; Kurchaninov, L. L.; Kurochkin, Y. A.; Kurth, M. G.; Kus, V.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; Kyriazopoulos, D.; La Rosa, A.; La Rosa Navarro, J. L.; La Rotonda, L.; Lacasta, C.; Lacava, F.; Lacey, J.; Lacker, H.; Lacour, D.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lanfermann, M. C.; Lang, V. S.; Lange, J. C.; Langenberg, R. J.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Lapertosa, A.; Laplace, S.; Laporte, J. F.; Lari, T.; Lasagni Manghi, F.; Lassnig, M.; Laurelli, P.; Lavrijsen, W.; Law, A. T.; Laycock, P.; Lazovich, T.; Lazzaroni, M.; Le, B.; Le Dortz, O.; Le Guirriec, E.; Le Quilleuc, E. P.; LeBlanc, M.; LeCompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, G. R.; Lee, S. C.; Lee, L.; Lefebvre, B.; Lefebvre, G.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehan, A.; Lehmann Miotto, G.; Lei, X.; Leight, W. A.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Lerner, G.; Leroy, C.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, D.; Li, B.; Li, Changqiao; Li, H.; Li, L.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liberti, B.; Liblong, A.; Lie, K.; Liebal, J.; Liebig, W.; Limosani, A.; Lin, S. C.; Lin, T. H.; Lindquist, B. E.; Lionti, A. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lister, A.; Litke, A. M.; Liu, B.; Liu, H.; Liu, H.; Liu, J. K. K.; Liu, J.; Liu, J. B.; Liu, K.; Liu, L.; Liu, M.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Llorente Merino, J.; Lloyd, S. L.; Lo, C. Y.; Lo Sterzo, F.; Lobodzinska, E. M.; Loch, P.; Loebinger, F. K.; Loesle, A.; Loew, K. M.; Loginov, A.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopez, J. A.; Lopez Mateos, D.; Lopez Paz, I.; Lopez Solis, A.; Lorenz, J.; Martinez, N. Lorenzo; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lu, Y. J.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lundberg, O.; Lund-Jensen, B.; Luzi, P. M.; Lynn, D.; Lysak, R.; Lytken, E.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; Macdonald, C. M.; Maček, B.; Machado Miguens, J.; Madaffari, D.; Madar, R.; Mader, W. F.; Madsen, A.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A. S.; Magradze, E.; Mahlstedt, J.; Maiani, C.; Maidantchik, C.; Maier, A. A.; Maier, T.; Maio, A.; Majersky, O.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandelli, L.; Mandić, I.; Maneira, J.; Filho, L. Manhaes de Andrade; Manjarres Ramos, J.; Mann, A.; Manousos, A.; Mansoulie, B.; Mansour, J. D.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Mapelli, L.; Marceca, G.; March, L.; Marchese, L.; Marchiori, G.; Marcisovsky, M.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marsden, S. P.; Marshall, Z.; Martensson, M. U. F.; Marti-Garcia, S.; Martin, C. B.; Martin, T. A.; Martin, V. J.; dit Latour, B. Martin; Martinez, M.; Martinez Outschoorn, V. I.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Maznas, I.; Mazza, S. M.; McFadden, N. C.; McGoldrick, G.; McKee, S. P.; McCarn, A.; McCarthy, R. L.; McCarthy, T. G.; McClymont, L. I.; McDonald, E. F.; Mcfayden, J. A.; Mchedlidze, G.; McMahon, S. J.; McNamara, P. C.; McPherson, R. A.; Meehan, S.; Megy, T. J.; Mehlhase, S.; Mehta, A.; Meideck, T.; Meier, K.; Meirose, B.; Melini, D.; Mellado Garcia, B. R.; Mellenthin, J. D.; Melo, M.; Meloni, F.; Menary, S. B.; Meng, L.; Meng, X. T.; Mengarelli, A.; Menke, S.; Meoni, E.; Mergelmeyer, S.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Theenhausen, H. Meyer Zu; Miano, F.; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Miller, D. W.; Mills, C.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minami, Y.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Minegishi, Y.; Ming, Y.; Mir, L. M.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mizukami, A.; Mjörnmark, J. U.; Mkrtchyan, T.; Mlynarikova, M.; Moa, T.; Mochizuki, K.; Mogg, P.; Mohapatra, S.; Molander, S.; Moles-Valls, R.; Monden, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Montejo Berlingen, J.; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Moreno Llácer, M.; Morettini, P.; Morgenstern, S.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morvaj, L.; Moschovakos, P.; Mosidze, M.; Moss, H. J.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Moyse, E. J. W.; Muanza, S.; Mudd, R. D.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Munoz Sanchez, F. J.; Murray, W. J.; Musheghyan, H.; Muškinja, M.; Myagkov, A. G.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Naranjo Garcia, R. F.; Narayan, R.; Narrias Villar, D. I.; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, A.; Nelson, M. E.; Nemecek, S.; Nemethy, P.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Newman, P. R.; Ng, T. Y.; Nguyen Manh, T.; Nickerson, R. B.; Nicolaidou, R.; Nielsen, J.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsen, J. K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nishu, N.; Nisius, R.; Nitsche, I.; Nitta, T.; Nobe, T.; Noguchi, Y.; Nomachi, M.; Nomidis, I.; Nomura, M. A.; Nooney, T.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Nowak, S.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'connor, K.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Ogren, H.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Oleiro Seabra, L. F.; Olivares Pino, S. A.; Oliveira Damazio, D.; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Garzon, G. Otero y.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pacheco Pages, A.; Pacheco Rodriguez, L.; Padilla Aranda, C.; Pagan Griso, S.; Paganini, M.; Paige, F.; Palacino, G.; Palazzo, S.; Palestini, S.; Palka, M.; Pallin, D.; Panagiotopoulou, E. St.; Panagoulias, I.; Pandini, C. E.; Panduro Vazquez, J. G.; Pani, P.; Panitkin, S.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Paredes Hernandez, D.; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasner, J. M.; Pasqualucci, E.; Passaggio, S.; Pastore, Fr.; Pataraia, S.; Pater, J. R.; Pauly, T.; Pearson, B.; Pedraza Lopez, S.; Pedro, R.; Peleganchuk, S. V.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Peri, F.; Perini, L.; Pernegger, H.; Perrella, S.; Peschke, R.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Phillips, F. H.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Piccaro, E.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pin, A. W. J.; Pinamonti, M.; Pinfold, J. L.; Pirumov, H.; Pitt, M.; Plazak, L.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Pluth, D.; Podberezko, P.; Poettgen, R.; Poggi, R.; Poggioli, L.; Pohl, D.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Pommès, K.; Ponomarenko, D.; Pontecorvo, L.; Pope, B. G.; Popeneciu, G. A.; Poppleton, A.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Poulard, G.; Poulsen, T.; Poveda, J.; Pozo Astigarraga, M. E.; Pralavorio, P.; Pranko, A.; Prell, S.; Price, D.; Price, L. E.; Primavera, M.; Prince, S.; Proklova, N.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puri, A.; Puzo, P.; Qian, J.; Qin, G.; Qin, Y.; Quadt, A.; Queitsch-Maitland, M.; Quilty, D.; Raddum, S.; Radeka, V.; Radescu, V.; Radhakrishnan, S. K.; Radloff, P.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rangel-Smith, C.; Rashid, T.; Raspopov, S.; Ratti, M. G.; Rauch, D. M.; Rauscher, F.; Rave, S.; Ravinovich, I.; Rawling, J. H.; Raymond, M.; Read, A. L.; Readioff, N. P.; Reale, M.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reed, R. G.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reiss, A.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Resseguie, E. D.; Rettie, S.; Reynolds, E.; Rezanova, O. L.; Reznicek, P.; Rezvani, R.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rieger, J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rimoldi, M.; Rinaldi, L.; Ripellino, G.; Ristić, B.; Ritsch, E.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Roberts, R. T.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Rocco, E.; Roda, C.; Rodina, Y.; Rodriguez Bosca, S.; Rodriguez Perez, A.; Rodriguez Rodriguez, D.; Roe, S.; Rogan, C. S.; RØhne, O.; Roloff, J.; Romaniouk, A.; Romano, M.; Romano Saez, S. M.; Romero Adam, E.; Rompotis, N.; Ronzani, M.; Roos, L.; Rosati, S.; Rosbach, K.; Rose, P.; Rosien, N.-A.; Rossi, E.; Rossi, L. P.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Roth, I.; Rothberg, J.; Rousseau, D.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Rzehorz, G. F.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Safai Tehrani, F.; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, M.; Saito, T.; Sakamoto, H.; Sakurai, Y.; Salamanna, G.; Salazar Loyola, J. E.; Salek, D.; Sales De Bruin, P. H.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sampsonidou, D.; Sánchez, J.; Sanchez Martinez, V.; Sanchez Pineda, A.; Sandaker, H.; Sandbach, R. L.; Sander, C. O.; Sandhoff, M.; Sandoval, C.; Sankey, D. P. C.; Sannino, M.; Sano, Y.; Sansoni, A.; Santoni, C.; Santonico, R.; Santos, H.; Santoyo Castillo, I.; Sapronov, A.; Saraiva, J. G.; Sarrazin, B.; Sasaki, O.; Sato, K.; Sauvan, E.; Savage, G.; Savard, P.; Savic, N.; Sawyer, C.; Sawyer, L.; Saxon, J.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Scarcella, M.; Scarfone, V.; Schaarschmidt, J.; Schacht, P.; Schachtner, B. M.; Schaefer, D.; Schaefer, L.; Schaefer, R.; Schaeffer, J.; Schaepe, S.; Schaetzel, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Scharf, V.; Schegelsky, V. A.; Scheirich, D.; Schernau, M.; Schiavi, C.; Schier, S.; Schildgen, L. K.; Schillo, C.; Schioppa, M.; Schlenker, S.; Schmidt-Sommerfeld, K. R.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schoenrock, B. D.; Schopf, E.; Schott, M.; Schouwenberg, J. F. P.; Schovancova, J.; Schramm, S.; Schuh, N.; Schulte, A.; Schultens, M. J.; Schultz-Coulon, H.-C.; Schulz, H.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwartzman, A.; Schwarz, T. A.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Sciandra, A.; Sciolla, G.; Scuri, F.; Scutti, F.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Semprini-Cesari, N.; Senkin, S.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Seuster, R.; Severini, H.; Sfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Shen, Y.; Sherafati, N.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shipsey, I. P. J.; Shirabe, S.; Shiyakova, M.; Shlomi, J.; Shmeleva, A.; Shoaleh Saadi, D.; Shochet, M. J.; Shojaii, S.; Shope, D. R.; Shrestha, S.; Shulga, E.; Shupe, M. A.; Sicho, P.; Sickles, A. M.; Sidebo, P. E.; Sideras Haddad, E.; Sidiropoulou, O.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silverstein, S. B.; Simak, V.; Simic, Lj.; Simion, S.; Simioni, E.; Simmons, B.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Siral, I.; Sivoklokov, S. Yu.; Sjölin, J.; Skinner, M. B.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smiesko, J.; Smirnov, N.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, J. W.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snyder, I. M.; Snyder, S.; Sobie, R.; Socher, F.; Soffer, A.; Soh, D. A.; Sokhrannyi, G.; Solans Sanchez, C. A.; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Sopczak, A.; Sosa, D.; Sotiropoulou, C. L.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spieker, T. M.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; St. Denis, R. D.; Stabile, A.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanitzki, M. M.; Stapf, B. S.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Stark, S. H.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stewart, G. A.; Stockton, M. C.; Stoebe, M.; Stoicea, G.; Stolte, P.; Stonjek, S.; Stradling, A. R.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultan, DMS; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Suruliz, K.; Suster, C. J. E.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Swift, S. P.; Sykora, I.; Sykora, T.; Ta, D.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Taiblum, N.; Takai, H.; Takashima, R.; Takasugi, E. H.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tanaka, J.; Tanaka, M.; Tanaka, R.; Tanaka, S.; Tanioka, R.; Tannenwald, B. B.; Tapia Araya, S.; Tapprogge, S.; Tarem, S.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Tavares Delgado, A.; Tayalati, Y.; Taylor, A. C.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teixeira-Dias, P.; Temple, D.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Theveneaux-Pelzer, T.; Thomas, J. P.; Thomas-Wilsker, J.; Thompson, P. D.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Tibbetts, M. J.; Ticse Torres, R. E.; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorova-Nova, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomlinson, L.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Tornambe, P.; Torrence, E.; Torres, H.; Torró Pastor, E.; Toth, J.; Touchard, F.; Tovey, D. R.; Treado, C. J.; Trefzger, T.; Tresoldi, F.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trottier-McDonald, M.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tsang, K. W.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsipolitis, G.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsui, K. M.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tu, Y.; Tudorache, A.; Tudorache, V.; Tulbure, T. T.; Tuna, A. N.; Tupputi, S. A.; Turchikhin, S.; Turgeman, D.; Turk Cakir, I.; Turra, R.; Tuts, P. M.; Ucchielli, G.; Ueda, I.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Unverdorben, C.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usui, J.; Vacavant, L.; Vacek, V.; Vachon, B.; Vaidya, A.; Valderanis, C.; Valdes Santurio, E.; Valentinetti, S.; Valero, A.; Valéry, L.; Valkar, S.; Vallier, A.; Valls Ferrer, J. A.; Van Den Wollenberg, W.; van der Graaf, H.; van Gemmeren, P.; Van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vardanyan, G.; Vari, R.; Varnes, E. W.; Varni, C.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vasquez, G. A.; Vazeille, F.; Vazquez Schroeder, T.; Veatch, J.; Veeraraghavan, V.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Venturini, A.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, A. T.; Vermeulen, J. C.; Vetterli, M. C.; Viaux Maira, N.; Viazlo, O.; Vichou, I.; Vickey, T.; Boeriu, O. E. Vickey; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Villa, M.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vishwakarma, A.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vogel, M.; Vokac, P.; Volpi, G.; von der Schmitt, H.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Voss, R.; Vossebeld, J. H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Wagner, W.; Wagner-Kuhr, J.; Wahlberg, H.; Wahrmund, S.; Wakabayashi, J.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, C.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, Q.; Wang, R.; Wang, S. M.; Wang, T.; Wang, W.; Wang, W.; Wang, Z.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, A. F.; Webb, S.; Weber, M. S.; Weber, S. W.; Weber, S. A.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weirich, M.; Weiser, C.; Weits, H.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M. D.; Werner, P.; Wessels, M.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A. S.; White, A.; White, M. J.; White, R.; Whiteson, D.; Whitmore, B. W.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winkels, E.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wobisch, M.; Wolf, T. M. H.; Wolff, R.; Wolter, M. W.; Wolters, H.; Wong, V. W. S.; Worm, S. D.; Wosiek, B. K.; Wotschack, J.; Wozniak, K. W.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xi, Z.; Xia, L.; Xu, D.; Xu, L.; Xu, T.; Yabsley, B.; Yacoob, S.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamamoto, S.; Yamanaka, T.; Yamatani, M.; Yamauchi, K.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Yau Wong, K. H.; Ye, J.; Ye, S.; Yeletskikh, I.; Yigitbasi, E.; Yildirim, E.; Yorita, K.; Yoshihara, K.; Young, C.; Young, C. J. S.; Yu, J.; Yu, J.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zacharis, G.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zaman, A.; Zambito, S.; Zanzi, D.; Zeitnitz, C.; Zemaityte, G.; Zemla, A.; Zeng, J. C.; Zeng, Q.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, L.; Zhang, M.; Zhang, P.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Y.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, M.; Zhou, M.; Zhou, N.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, C.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Zou, R.; zur Nedden, M.; Zwalinski, L.

    2017-12-01

    The ATLAS inner detector comprises three different sub-detectors: the pixel detector, the silicon strip tracker, and the transition-radiation drift-tube tracker. The Insertable B-Layer, a new innermost pixel layer, was installed during the shutdown period in 2014, together with modifications to the layout of the cables and support structures of the existing pixel detector. The material in the inner detector is studied with several methods, using a low-luminosity √s=13 TeV pp collision sample corresponding to around 2.0 nb-1 collected in 2015 with the ATLAS experiment at the LHC. In this paper, the material within the innermost barrel region is studied using reconstructed hadronic interaction and photon conversion vertices. For the forward rapidity region, the material is probed by a measurement of the efficiency with which single tracks reconstructed from pixel detector hits alone can be extended with hits on the track in the strip layers. The results of these studies have been taken into account in an improved description of the material in the ATLAS inner detector simulation, resulting in a reduction in the uncertainties associated with the charged-particle reconstruction efficiency determined from simulation.

  12. Study of the material of the ATLAS inner detector for Run 2 of the LHC

    DOE PAGES

    Aaboud, M.; Aad, G.; Abbott, B.; ...

    2017-12-07

    The ATLAS inner detector comprises three different sub-detectors: the pixel detector, the silicon strip tracker, and the transition-radiation drift-tube tracker. The Insertable B-Layer, a new innermost pixel layer, was installed during the shutdown period in 2014, together with modifications to the layout of the cables and support structures of the existing pixel detector. The material in the inner detector is studied with several methods, using a low-luminosity √s = 13 TeV pp collision sample corresponding to around 2.0 nb -1 collected in 2015 with the ATLAS experiment at the LHC. In this paper, the material within the innermost barrel regionmore » is studied using reconstructed hadronic interaction and photon conversion vertices. For the forward rapidity region, the material is probed by a measurement of the efficiency with which single tracks reconstructed from pixel detector hits alone can be extended with hits on the track in the strip layers. The results of these studies have been taken into account in an improved description of the material in the ATLAS inner detector simulation, resulting in a reduction in the uncertainties associated with the charged-particle reconstruction efficiency determined from simulation.« less

  13. Method of incident low-energy gamma-ray direction reconstruction in the GAMMA-400 gamma-ray space telescope

    NASA Astrophysics Data System (ADS)

    Kheymits, M. D.; Leonov, A. A.; Zverev, V. G.; Galper, A. M.; Arkhangelskaya, I. V.; Arkhangelskiy, A. I.; Suchkov, S. I.; Topchiev, N. P.; Yurkin, Yu T.; Bakaldin, A. V.; Dalkarov, O. D.

    2016-02-01

    The GAMMA-400 gamma-ray space-based telescope has as its main goals to measure cosmic γ-ray fluxes and the electron-positron cosmic-ray component produced, theoretically, in dark-matter-particles decay or annihilation processes, to search for discrete γ-ray sources and study them in detail, to examine the energy spectra of diffuse γ-rays — both galactic and extragalactic — and to study gamma-ray bursts (GRBs) and γ-rays from the active Sun. Scientific goals of GAMMA-400 telescope require fine angular resolution. The telescope is of a pair-production type. In the converter-tracker, the incident gamma-ray photon converts into electron-positron pair in the tungsten layer and then the tracks are detected by silicon- strip position-sensitive detectors. Multiple scattering processes become a significant obstacle in the incident-gamma direction reconstruction for energies below several gigaelectronvolts. The method of utilising this process to improve the resolution is proposed in the presented work.

  14. Tracking-Learning-Detection.

    PubMed

    Kalal, Zdenek; Mikolajczyk, Krystian; Matas, Jiri

    2012-07-01

    This paper investigates long-term tracking of unknown objects in a video stream. The object is defined by its location and extent in a single frame. In every frame that follows, the task is to determine the object's location and extent or indicate that the object is not present. We propose a novel tracking framework (TLD) that explicitly decomposes the long-term tracking task into tracking, learning, and detection. The tracker follows the object from frame to frame. The detector localizes all appearances that have been observed so far and corrects the tracker if necessary. The learning estimates the detector's errors and updates it to avoid these errors in the future. We study how to identify the detector's errors and learn from them. We develop a novel learning method (P-N learning) which estimates the errors by a pair of "experts": (1) P-expert estimates missed detections, and (2) N-expert estimates false alarms. The learning process is modeled as a discrete dynamical system and the conditions under which the learning guarantees improvement are found. We describe our real-time implementation of the TLD framework and the P-N learning. We carry out an extensive quantitative evaluation which shows a significant improvement over state-of-the-art approaches.

  15. Trapping in irradiated p +-n-n - silicon sensors at fluences anticipated at the HL-LHC outer tracker

    DOE PAGES

    Adam, W.

    2016-04-22

    The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200μm thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to 3 x 10 15 neq/cm 2. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulationmore » assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. Furthermore, the effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.« less

  16. Alpha voltaic batteries and methods thereof

    NASA Technical Reports Server (NTRS)

    Jenkins, Phillip (Inventor); Scheiman, David (Inventor); Castro, Stephanie (Inventor); Raffaelle, Ryne P. (Inventor); Wilt, David (Inventor); Chubb, Donald (Inventor)

    2011-01-01

    An alpha voltaic battery includes at least one layer of a semiconductor material comprising at least one p/n junction, at least one absorption and conversion layer on the at least one layer of semiconductor layer, and at least one alpha particle emitter. The absorption and conversion layer prevents at least a portion of alpha particles from the alpha particle emitter from damaging the p/n junction in the layer of semiconductor material. The absorption and conversion layer also converts at least a portion of energy from the alpha particles into electron-hole pairs for collection by the one p/n junction in the layer of semiconductor material.

  17. Quantum teleportation in the spin-orbit variables of photon pairs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khoury, A. Z.; Milman, P.; Laboratoire Materiaux et Phenomenes Quantiques, CNRS UMR 7162, Universite Paris Diderot, F-75013, Paris

    2011-06-15

    We propose a polarization to orbital angular momentum teleportation scheme using entangled photon pairs generated by spontaneous parametric down-conversion. By making a joint detection of the polarization and angular momentum parity of a single photon, we are able to detect all the Bell states and perform, in principle, perfect teleportation from a discrete to a continuous system using minimal resources. The proposed protocol implementation demands experimental resources that are currently available in quantum optics laboratories.

  18. Franson Interference Generated by a Two-Level System

    NASA Astrophysics Data System (ADS)

    Peiris, M.; Konthasinghe, K.; Muller, A.

    2017-01-01

    We report a Franson interferometry experiment based on correlated photon pairs generated via frequency-filtered scattered light from a near-resonantly driven two-level semiconductor quantum dot. In contrast to spontaneous parametric down-conversion and four-wave mixing, this approach can produce single pairs of correlated photons. We have measured a Franson visibility as high as 66%, which goes beyond the classical limit of 50% and approaches the limit of violation of Bell's inequalities (70.7%).

  19. IR studies of the impact of Ge doping on the successive conversion of VOn defects in Czochralski-Si containing carbon

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Andrianakis, A.; Sgourou, E. N.; Emtsev, V. V.; Ohyama, H.

    2011-02-01

    We report infrared absorption studies of oxygen-related defects in electron-irradiated Ge-doped Czochralski-Si. Our investigation was mainly focused on the reaction channel leading to the formation of VOn (1≤n≤6) defects. The VOn defects form mainly upon annealing, as a result of the successive aggregation of oxygen atoms in the initial VO defect produced by the irradiation: (VO+Oi→VO2+Oi→VO3+Oi→VO4,…). It was found that the ratio of the conversion of VOn to VOn+1 defects is sensitive to the Ge content of the material. In particular, the ratio of the conversion of the VO to the VO2 defects was found to decrease with the increase in Ge concentration of the samples, although the opposite trend was observed for the VO3 to VO4 conversion. However, the VO2 to VO3 conversion changes only slightly with Ge content, being practically unaffected for Ge concentrations up to 2×1020 cm-3. In the case of VO2 formation, the phenomenon was attributed to the elastic strains induced in the lattice due to the Ge presence which affects the balance between the reactions VO+Oi→VO2, VO+SiI→Oi, mainly involved in the decay of the VO and the growth of the VO2 defects. In the case of VO4 formation, the phenomenon was discussed by taking into account the enhancement of the diffusivity of the Oi atoms in the Ge-doped Si, which could lead to an enhancement of the rate of the reaction VO3+Oi→VO4. For the VO3 formation this effect is practically negligible due to the fact that at the temperatures of VO2 to VO3 conversion oxygen diffusivity is quite small. The exhibited behavior in the conversion of the VOn to VOn+1 defects (n=1,2,3) was similar in Ge-doped samples with low carbon content ([Cs]<2×1016 cm-3) and in Ge-doped samples with high carbon content ([Cs]≥1×1017 cm-3). The impact of C as well as its role in the conversion efficiency of VO to VO2 was studied by comparing the spectra in low carbon and high carbon Ge free Si material. Furthermore, a pair of bands at (1037,1051 cm-1) was attributed to the VO5 defect. The origin of another pair of bands (967,1005 cm-1) was discussed and tentatively correlated with a VOnCs structure. The role of Ge and C in the formation of the latter two pairs of bands was discussed.

  20. Japanese mothers’ utterances about agents and actions during joint picture-book reading

    PubMed Central

    Murase, Toshiki

    2013-01-01

    This study extended the research on the scaffolding provided by mothers while reading picture books with their children from a focus on conversational styles related to labeling to a focus on those related to agents and actions to clarify the process by which language develops from the one-word to the syntactic stage. We clarified whether mothers decreased the degree of scaffolding in their initiation of conversations, in the responses to their children’s utterances, and in the choice of referential ranges of their utterances. We also investigated whether maternal conversational styles contributed to the development of their children’s vocabularies. Eighteen pairs of Japanese mothers and their children were longitudinally observed when the children were 20 and 27 months of age. The pairs were given a picture book depicting 24 animals engaged in everyday behavior. The mothers shifted their approach in the initiation of conversation from providing to requesting information as a function of their children’s age. The proportion of maternal elaborative information-seeking responses was positively correlated with the size of their children’s productive vocabulary. In terms of referential choices, mothers broadened the range of their references as their children aged. In terms of the contribution of maternal conversational styles to children’s vocabulary development, the use of a maternal elaborative information-seeking style when the children were 20 months of age predicted the size of the children’s productive vocabulary at 27 months. These results indicate that mothers decrease the degree of scaffolding by introducing more complex information into the conversations and transferring the role of actively producing information to their children by requesting information as their children develop. The results also indicate that these conversational styles promote the development of children’s vocabularies during the transition from the one-word to the syntactic stage. PMID:24847288

  1. Coevolution of Siglec-11 and Siglec-16 via gene conversion in primates.

    PubMed

    Hayakawa, Toshiyuki; Khedri, Zahra; Schwarz, Flavio; Landig, Corinna; Liang, Suh-Yuen; Yu, Hai; Chen, Xi; Fujito, Naoko T; Satta, Yoko; Varki, Ajit; Angata, Takashi

    2017-11-23

    Siglecs-11 and -16 are members of the sialic acid recognizing Ig-like lectin family, and expressed in same cells. Siglec-11 functions as an inhibitory receptor, whereas Siglec-16 exhibits activating properties. In humans, SIGLEC11 and SIGLEC16 gene sequences are extremely similar in the region encoding the extracellular domain due to gene conversions. Human SIGLEC11 was converted by the nonfunctional SIGLEC16P allele, and the converted SIGLEC11 allele became fixed in humans, possibly because it provides novel neuroprotective functions in brain microglia. However, the detailed evolutionary history of SIGLEC11 and SIGLEC16 in other primates remains unclear. We analyzed SIGLEC11 and SIGLEC16 gene sequences of multiple primate species, and examined glycan binding profiles of these Siglecs. The phylogenetic tree demonstrated that gene conversions between SIGLEC11 and SIGLEC16 occurred in the region including the exon encoding the sialic acid binding domain in every primate examined. Functional assays showed that glycan binding preference is similar between Siglec-11 and Siglec-16 in all analyzed hominid species. Taken together with the fact that Siglec-11 and Siglec-16 are expressed in the same cells, Siglec-11 and Siglec-16 are regarded as paired receptors that have maintained similar ligand binding preferences via gene conversions. Relaxed functional constraints were detected on the SIGLEC11 and SIGLEC16 exons that underwent gene conversions, possibly contributing to the evolutionary acceptance of repeated gene conversions. The frequency of nonfunctional SIGLEC16P alleles is much higher than that of SIGLEC16 alleles in every human population. Our findings indicate that Siglec-11 and Siglec-16 have been maintained as paired receptors by repeated gene conversions under relaxed functional constraints in the primate lineage. The high prevalence of the nonfunctional SIGLEC16P allele and the fixation of the converted SIGLEC11 imply that the loss of Siglec-16 and the gain of Siglec-11 in microglia might have been favored during the evolution of human lineage.

  2. Another look at retroactive and proactive interference: a quantitative analysis of conversion processes.

    PubMed

    Blank, Hartmut

    2005-02-01

    Traditionally, the causes of interference phenomena were sought in "real" or "hard" memory processes such as unlearning, response competition, or inhibition, which serve to reduce the accessibility of target items. I propose an alternative approach which does not deny the influence of such processes but highlights a second, equally important, source of interference-the conversion (Tulving, 1983) of accessible memory information into memory performance. Conversion is conceived as a problem-solving-like activity in which the rememberer tries to find solutions to a memory task. Conversion-based interference effects are traced to different conversion processes in the experimental and control conditions of interference designs. I present a simple theoretical model that quantitatively predicts the resulting amount of interference. In two paired-associate learning experiments using two different types of memory tests, these predictions were corroborated. Relations of the present approach to traditional accounts of interference phenomena and implications for eyewitness testimony are discussed.

  3. System and method for calibrating inter-star-tracker misalignments in a stellar inertial attitude determination system

    NASA Technical Reports Server (NTRS)

    Li, Rongsheng (Inventor); Wu, Yeong-Wei Andy (Inventor); Hein, Douglas H. (Inventor)

    2004-01-01

    A method and apparatus for determining star tracker misalignments is disclosed. The method comprises the steps of defining a defining a reference frame for the star tracker assembly according to a boresight of the primary star tracker and a boresight of a second star tracker wherein the boresight of the primary star tracker and a plane spanned by the boresight of the primary star tracker and the boresight of the second star tracker at least partially define a datum for the reference frame for the star tracker assembly; and determining the misalignment of the at least one star tracker as a rotation of the defined reference frame.

  4. Spectroscopy of Isolated Prebiotic Nucleobases

    NASA Technical Reports Server (NTRS)

    Svadlenak, Nathan; Callahan, Michael P.; Ligare, Marshall; Gulian, Lisa; Gengeliczki, Zsolt; Nachtigallova, Dana; Hobza, Pavel; deVries, Mattanjah

    2011-01-01

    We use multiphoton ionization and double resonance spectroscopy to study the excited state dynamics of biologically relevant molecules as well as prebiotic nucleobases, isolated in the gas phase. Molecules that are biologically relevant to life today tend to exhibit short excited state lifetimes compared to similar but non-biologically relevant analogs. The mechanism is internal conversion, which may help protect the biologically active molecules from UV damage. This process is governed by conical intersections that depend very strongly on molecular structure. Therefore we have studied purines and pyrimidines with systematic variations of structure, including substitutions, tautomeric forms, and cluster structures that represent different base pair binding motifs. These structural variations also include possible alternate base pairs that may shed light on prebiotic chemistry. With this in mind we have begun to probe the ultrafast dynamics of molecules that exhibit very short excited states and search for evidence of internal conversions.

  5. Highly efficient heralded single-photon source for telecom wavelengths based on a PPLN waveguide.

    PubMed

    Bock, Matthias; Lenhard, Andreas; Chunnilall, Christopher; Becher, Christoph

    2016-10-17

    We present the realization of a highly efficient photon pair source based on spontaneous parametric downconversion (SPDC) in a periodically poled lithium niobate (PPLN) ridge waveguide. The source is suitable for long distance quantum communication applications as the photon pairs are located at the centers of the telecommunication O- and C- band at 1312 nm and 1557 nm. The high efficiency is confirmed by a conversion efficiency of 4 × 10-6 - which is to our knowledge among the highest conversion efficiencies reported so far - and a heralding efficiency of 64.1 ± 2.1%. The heralded single-photon properties are confirmed by the measurement of the photon statistics with a Click/No-Click method as well as the heralded g(2)-function. A minimum value for g(2)(0) of 0.001 ± 0.0003 indicating clear antibunching has been observed.

  6. Temporal Multimode Storage of Entangled Photon Pairs

    NASA Astrophysics Data System (ADS)

    Tiranov, Alexey; Strassmann, Peter C.; Lavoie, Jonathan; Brunner, Nicolas; Huber, Marcus; Verma, Varun B.; Nam, Sae Woo; Mirin, Richard P.; Lita, Adriana E.; Marsili, Francesco; Afzelius, Mikael; Bussières, Félix; Gisin, Nicolas

    2016-12-01

    Multiplexed quantum memories capable of storing and processing entangled photons are essential for the development of quantum networks. In this context, we demonstrate and certify the simultaneous storage and retrieval of two entangled photons inside a solid-state quantum memory and measure a temporal multimode capacity of ten modes. This is achieved by producing two polarization-entangled pairs from parametric down-conversion and mapping one photon of each pair onto a rare-earth-ion-doped (REID) crystal using the atomic frequency comb (AFC) protocol. We develop a concept of indirect entanglement witnesses, which can be used as Schmidt number witnesses, and we use it to experimentally certify the presence of more than one entangled pair retrieved from the quantum memory. Our work puts forward REID-AFC as a platform compatible with temporal multiplexing of several entangled photon pairs along with a new entanglement certification method, useful for the characterization of multiplexed quantum memories.

  7. High-Efficiency Solar Cells Using Photonic-Bandgap Materials

    NASA Technical Reports Server (NTRS)

    Dowling, Jonathan; Lee, Hwang

    2005-01-01

    Solar photovoltaic cells would be designed to exploit photonic-bandgap (PBG) materials to enhance their energy-conversion efficiencies, according to a proposal. Whereas the energy-conversion efficiencies of currently available solar cells are typically less than 30 percent, it has been estimated that the energy-conversion efficiencies of the proposed cells could be about 50 percent or possibly even greater. The primary source of inefficiency of a currently available solar cell is the mismatch between the narrow wavelength band associated with the semiconductor energy gap (the bandgap) and the broad wavelength band of solar radiation. This mismatch results in loss of power from both (1) long-wavelength photons, defined here as photons that do not have enough energy to excite electron-hole pairs across the bandgap, and (2) short-wavelength photons, defined here as photons that excite electron- hole pairs with energies much above the bandgap. It follows that a large increase in efficiency could be obtained if a large portion of the incident solar energy could be funneled into a narrow wavelength band corresponding to the bandgap. In the proposed approach, such funneling would be effected by use of PBG materials as intermediaries between the Sun and photovoltaic cells.

  8. Isolated and soft-switched power converter

    DOEpatents

    Peng, Fang Zheng; Adams, Donald Joe

    2002-01-01

    An isolated and soft-switched power converter is used for DC/DC and DC/DC/AC power conversion. The power converter includes two resonant tank circuits coupled back-to-back through an isolation transformer. Each resonant tank circuit includes a pair of resonant capacitors connected in series as a resonant leg, a pair of tank capacitors connected in series as a tank leg, and a pair of switching devices with anti-parallel clamping diodes coupled in series as resonant switches and clamping devices for the resonant leg. The power converter is well suited for DC/DC and DC/DC/AC power conversion applications in which high-voltage isolation, DC to DC voltage boost, bidirectional power flow, and a minimal number of conventional switching components are important design objectives. For example, the power converter is especially well suited to electric vehicle applications and load-side electric generation and storage systems, and other applications in which these objectives are important. The power converter may be used for many different applications, including electric vehicles, hybrid combustion/electric vehicles, fuel-cell powered vehicles with low-voltage starting, remote power sources utilizing low-voltage DC power sources, such as photovoltaics and others, electric power backup systems, and load-side electric storage and generation systems.

  9. The entangled triplet pair state in acene and heteroacene materials

    PubMed Central

    Yong, Chaw Keong; Musser, Andrew J.; Bayliss, Sam L.; Lukman, Steven; Tamura, Hiroyuki; Bubnova, Olga; Hallani, Rawad K.; Meneau, Aurélie; Resel, Roland; Maruyama, Munetaka; Hotta, Shu; Herz, Laura M.; Beljonne, David; Anthony, John E.; Clark, Jenny; Sirringhaus, Henning

    2017-01-01

    Entanglement of states is one of the most surprising and counter-intuitive consequences of quantum mechanics, with potent applications in cryptography and computing. In organic materials, one particularly significant manifestation is the spin-entangled triplet-pair state, which mediates the spin-conserving fission of one spin-0 singlet exciton into two spin-1 triplet excitons. Despite long theoretical and experimental exploration, the nature of the triplet-pair state and inter-triplet interactions have proved elusive. Here we use a range of organic semiconductors that undergo singlet exciton fission to reveal the photophysical properties of entangled triplet-pair states. We find that the triplet pair is bound with respect to free triplets with an energy that is largely material independent (∼30 meV). During its lifetime, the component triplets behave cooperatively as a singlet and emit light through a Herzberg–Teller-type mechanism, resulting in vibronically structured photoluminescence. In photovoltaic blends, charge transfer can occur from the bound triplet pairs with >100% photon-to-charge conversion efficiency. PMID:28699637

  10. The entangled triplet pair state in acene and heteroacene materials

    NASA Astrophysics Data System (ADS)

    Yong, Chaw Keong; Musser, Andrew J.; Bayliss, Sam L.; Lukman, Steven; Tamura, Hiroyuki; Bubnova, Olga; Hallani, Rawad K.; Meneau, Aurélie; Resel, Roland; Maruyama, Munetaka; Hotta, Shu; Herz, Laura M.; Beljonne, David; Anthony, John E.; Clark, Jenny; Sirringhaus, Henning

    2017-07-01

    Entanglement of states is one of the most surprising and counter-intuitive consequences of quantum mechanics, with potent applications in cryptography and computing. In organic materials, one particularly significant manifestation is the spin-entangled triplet-pair state, which mediates the spin-conserving fission of one spin-0 singlet exciton into two spin-1 triplet excitons. Despite long theoretical and experimental exploration, the nature of the triplet-pair state and inter-triplet interactions have proved elusive. Here we use a range of organic semiconductors that undergo singlet exciton fission to reveal the photophysical properties of entangled triplet-pair states. We find that the triplet pair is bound with respect to free triplets with an energy that is largely material independent (~30 meV). During its lifetime, the component triplets behave cooperatively as a singlet and emit light through a Herzberg-Teller-type mechanism, resulting in vibronically structured photoluminescence. In photovoltaic blends, charge transfer can occur from the bound triplet pairs with >100% photon-to-charge conversion efficiency.

  11. A Multidirectional Tribo-System: Wear of UHMWPE under Sliding, Rolling, and Rotation

    NASA Astrophysics Data System (ADS)

    Patten, Elias Wolfgang

    Total knee replacements (TKR) have become a successful surgical procedure for addressing end-stage osteoarthritis, with ultra-high molecular weight polyethylene and cobalt chrome alloy (UHMWPE/Co-Cr) serving as the bearing materials of choice for decades. However, more than 10% of TKRs fail and require revision surgery. The predominant challenge with UHMWPE is the particulate debris generated through wear-mediated processes; wear debris from the UHMWPE tibial bearing surface leading to loosening is still the main cause for post-fifth-year revisions. UHMWPE wear in hip arthroplasty has been linked to microstructural evolution at the surface from multidirectional sliding in the hip joint but little is known about how the microstructure responds to clinically relevant sliding conditions in the knee. This is likely because wear tests are typically performed under basic motion parameters with simplified geometry (pin-on-disk tests) while the knee has more complex kinematics: it is neither a ball-and-socket joint nor a simple hinge joint, but has 2D sliding, rolling/slip motion, and rotation. There is also disagreement over how to best quantify cross-shear and how to model how much wear it will cause. A custom multidirectional tribo-system was used to investigate the individual and combined effects of the different motions in TKR: 2D sliding, rolling, and rotation, for a total of eight separate kinematic conditions. The trends in wear rates and wear factors for these different motions were compared with many different definitions for magnitudes and ratios of cross-shear. Additionally, the wear surfaces were examined for wear mechanism and the microstructural changes in lamellae orientation for the different motions were analyzed. To mimic the tribological conditions of a condyle in a TKR, polished Co-Cr spheres were articulated against flat, smooth UHMWPE disks with physiologically relevant loading, speed, and lubrication conditions. The motion parameters were selected based on the lowest and highest reasonable amounts of cross-shear that each motion type would generate during a realistic gait cycle: a reciprocating line or a "figure 8" with a 15° crossing angle, no rolling or a 0.4 slide-to-roll ratio, and no rotation or a 1°/mm of rotation. The amount of wear was measured with optical profilometry of the cross-section at the middle of the wear scar, after allowing for a resting period for the material creep to recover. To calculate the amount of cross-shear at this cross-section, the sliding interface was simulated with a computer Matlab model. Multiple definitions of cross-shear were used, including the traditional, cycle-based approaches and newer, memory-based approaches. The wear surfaces were examined using optical microscopy and scanning electron microscopy (SEM). The lamellar microstructure at the wear surface and below the wear surface was examined using an oxidizing etch to remove the amorphous phase. The remaining lamellae were imaged using SEM and their orientations and alignment was quantified using an image analysis program. Wear factors were between 0.3 and 8.7 µm2/(Nm/mm), significantly increasing with motion complexity and cross-shear, with the "figure 8" sliding path having the greatest effect. Volumetric wear rates correlated linearly with the total amount of cross-shear, while wear factors correlated linearly with ratios of cross-shear. The best predictors of the wear factor were the normalized crossing intensity and normalized, memory-based cross-shear ratios, with R2 values of 0.98 and 0.97, although many of the cross-shear ratios also had a good linear fits with wear factor. The kinematic parameters in this experiment did not differentiate the various cross-shear parameters enough to conclusively determine which are most appropriate, although some have a stronger theoretical foundation than others. SEM analysis of the wear scar surface revealed slight scratching and instances of rippling and surface cracking perpendicular to the primary sliding directions. These are consistent with abrasive wear, plastic flow and adhesive wear, and fatigue wear mechanisms reported in other in vitro and in vivo wear studies. The orientations of the lamellae at the wear surfaces were not discernibly different from the lamellae of an unworn section of the disk surface. Similarly, the near-surface regions of the disk cross-section were not discernibly different from the subsurface regions. Previous studies have demonstrated orientation of the microstructure during wear using transmission electron microscopy, X-ray scattering, and Fourier transform infrared spectroscopy techniques, and such methods may be necessary for texture characterization. These results demonstrate that knee kinematics have a significant effect on the cross-shear and wear of UHMWPE and should not be neglected when designing TKR. A better theoretical understanding of how kinematics contribute to wear can lead to better UHMWPE formulations, improved computer simulations of wear, and optimized TKR designs with longer life-spans.

  12. Text-mining as a methodology to assess eating disorder-relevant factors: Comparing mentions of fitness tracking technology across online communities.

    PubMed

    McCaig, Duncan; Bhatia, Sudeep; Elliott, Mark T; Walasek, Lukasz; Meyer, Caroline

    2018-05-07

    Text-mining offers a technique to identify and extract information from a large corpus of textual data. As an example, this study presents the application of text-mining to assess and compare interest in fitness tracking technology across eating disorder and health-related online communities. A list of fitness tracking technology terms was developed, and communities (i.e., 'subreddits') on a large online discussion platform (Reddit) were compared regarding the frequency with which these terms occurred. The corpus used in this study comprised all comments posted between May 2015 and January 2018 (inclusive) on six subreddits-three eating disorder-related, and three relating to either fitness, weight-management, or nutrition. All comments relating to the same 'thread' (i.e., conversation) were concatenated, and formed the cases used in this study (N = 377,276). Within the eating disorder-related subreddits, the findings indicated that a 'pro-eating disorder' subreddit, which is less recovery focused than the other eating disorder subreddits, had the highest frequency of fitness tracker terms. Across all subreddits, the weight-management subreddit had the highest frequency of the fitness tracker terms' occurrence, and MyFitnessPal was the most frequently mentioned fitness tracker. The technique exemplified here can potentially be used to assess group differences to identify at-risk populations, generate and explore clinically relevant research questions in populations who are difficult to recruit, and scope an area for which there is little extant literature. The technique also facilitates methodological triangulation of research findings obtained through more 'traditional' techniques, such as surveys or interviews. © 2018 Wiley Periodicals, Inc.

  13. General Conversion for Obtaining Strongly Existentially Unforgeable Signatures

    NASA Astrophysics Data System (ADS)

    Teranishi, Isamu; Oyama, Takuro; Ogata, Wakaha

    We say that a signature scheme is strongly existentially unforgeable (SEU) if no adversary, given message/signature pairs adaptively, can generate a signature on a new message or a new signature on a previously signed message. We propose a general and efficient conversion in the standard model that transforms a secure signature scheme to SEU signature scheme. In order to construct that conversion, we use a chameleon commitment scheme. Here a chameleon commitment scheme is a variant of commitment scheme such that one can change the committed value after publishing the commitment if one knows the secret key. We define the chosen message security notion for the chameleon commitment scheme, and show that the signature scheme transformed by our proposed conversion satisfies the SEU property if the chameleon commitment scheme is chosen message secure. By modifying the proposed conversion, we also give a general and efficient conversion in the random oracle model, that transforms a secure signature scheme into a SEU signature scheme. This second conversion also uses a chameleon commitment scheme but only requires the key only attack security for it.

  14. Two-photon geometrical phase

    NASA Astrophysics Data System (ADS)

    Strekalov, D. V.; Shih, Y. H.

    1997-10-01

    An advanced wave model is applied to a two-photon interference experiment to show that the observed interference effect is due to the geometrical phase of a two-photon state produced in spontaneous parametric down-conversion. The polarization state of the signal-idler pair is changed adiabatically so that the ``loop'' on the Poincaré sphere is opened in the signal channel and closed in the idler channel. Therefore, we observed an essentially nonlocal geometrical phase, shared by the entangled photon pair, or a biphoton.

  15. Three-photon N00N states generated by photon subtraction from double photon pairs.

    PubMed

    Kim, Heonoh; Park, Hee Su; Choi, Sang-Kyung

    2009-10-26

    We describe an experimental demonstration of a novel three-photon N00N state generation scheme using a single source of photons based on spontaneous parametric down-conversion (SPDC). The three-photon entangled state is generated when a photon is subtracted from a double pair of photons and detected by a heralding counter. Interference fringes measured with an emulated three-photon detector reveal the three-photon de Broglie wavelength and exhibit visibility > 70% without background subtraction.

  16. Generation of High Purity Photon-Pair in a Short Highly Non-Linear Fiber

    DTIC Science & Technology

    2013-01-01

    Avalanche photodiode. A 10 m long HNLF fabricated by Sumitomo with a core diameter of 4 microns is fusion spliced to a single mode fiber for a...parametric down conversion (SPDC) was first observed in χ(2) nonlinear crystal [3]. However, the compatibility of a nonlinear crystal source with fiber and...PAIR IN A SHORT HIGHLY NON-LINEAR FIBER 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA8750-12-1-0136 5c. PROGRAM ELEMENT NUMBER N/A 6. AUTHOR(S

  17. Support effects in catalysis studied by in-situ sum frequency generation vibrational spectroscopy and in-situ x-ray spectroscopies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, Griffin John

    Here, kinetic measurements are paired with in-situ spectroscopic characterization tools to investigate colloidally based, supported Pt catalytic model systems in order to elucidate the mechanisms by which metal and support work in tandem to dictate activity and selectivity. The results demonstrate oxide support materials, while inactive in absence of Pt nanoparticles, possess unique active sites for the selective conversion of gas phase molecules when paired with an active metal catalyst.

  18. TOTAL KNEE REPLACEMENT IN PATIENTS WITH BELOW-KNEE AMPUTATION

    PubMed Central

    Karam, Matthew D; Willey, Michael; Shurr, Donald G

    2010-01-01

    Total knee replacement (TKR) is reserved for patients with severe and disabling arthritis that is non-responsive to conservative measures. Based on existing data, total knee replacement is a safe and cost-effective treatment for alleviating pain and improving physical function in patients who do not respond to conservative therapy. Despite the large variation in health status of patients and types of prosthesis implanted, total knee replacement has proven to be a relatively low risk and successful operation. Each year in the United States surgeons perform approximately 300,000 TKR.1 Likewise, lower extremity amputation is commonly performed in the United States with an annual incidence of 110,000 per year.2 Nearly 70% of all lower extremity amputations are performed as the result of chronic vascular disease, followed by trauma (22%), congenital etiology and tumor (4% each).3 Approximately 50% of all lower extremity amputations are performed secondary to complications from Diabetes Mellitus. Norvell et al. demonstrated that patients who have previously undergone transtibial amputation and ambulate with a prosthesis are more likely to develop degenerative joint disease in the con-tralateral extremity than the ipsilateral extremity.4 Further, radiographic changes consistent with osteoporosis have been demonstrated in up to 88% of limbs that have undergone transtibial amputation.8 To our knowledge, there have been only three reported cases of total knee replacement in patients with ipsilateral transtibial amputation.5,7 The purpose of the present study is to review the existing data on total knee replacement in patients who have undergone transtibial amputation. Further we present a patient with a transtibial amputation who underwent contralateral total knee replacement. PMID:21045987

  19. Tibiofemoral wear in standard and non-standard squat: implication for total knee arthroplasty.

    PubMed

    Fekete, Gusztáv; Sun, Dong; Gu, Yaodong; Neis, Patric Daniel; Ferreira, Ney Francisco; Innocenti, Bernardo; Csizmadia, Béla M

    2017-01-01

    Due to the more resilient biomaterials, problems related to wear in total knee replacements (TKRs) have decreased but not disappeared. In the design-related factors, wear is still the second most important mechanical factor that limits the lifetime of TKRs and it is also highly influenced by the local kinematics of the knee. During wear experiments, constant load and slide-roll ratio is frequently applied in tribo-tests beside other important parameters. Nevertheless, numerous studies demonstrated that constant slide-roll ratio is not accurate approach if TKR wear is modelled, while instead of a constant load, a flexion-angle dependent tibiofemoral force should be involved into the wear model to obtain realistic results. A new analytical wear model, based upon Archard's law, is introduced, which can determine the effect of the tibiofemoral force and the varying slide-roll on wear between the tibiofemoral connection under standard and non-standard squat movement. The calculated total wear with constant slide-roll during standard squat was 5.5 times higher compared to the reference value, while if total wear includes varying slide-roll during standard squat, the calculated wear was approximately 6.25 times higher. With regard to non-standard squat, total wear with constant slide-roll during standard squat was 4.16 times higher than the reference value. If total wear included varying slide-roll, the calculated wear was approximately 4.75 times higher. It was demonstrated that the augmented force parameter solely caused 65% higher wear volume while the slide-roll ratio itself increased wear volume by 15% higher compared to the reference value. These results state that the force component has the major effect on wear propagation while non-standard squat should be proposed for TKR patients as rehabilitation exercise.

  20. Tibiofemoral wear in standard and non-standard squat: implication for total knee arthroplasty

    PubMed Central

    Sun, Dong; Gu, Yaodong; Neis, Patric Daniel; Ferreira, Ney Francisco; Innocenti, Bernardo; Csizmadia, Béla M.

    2017-01-01

    Summary Introduction Due to the more resilient biomaterials, problems related to wear in total knee replacements (TKRs) have decreased but not disappeared. In the design-related factors, wear is still the second most important mechanical factor that limits the lifetime of TKRs and it is also highly influenced by the local kinematics of the knee. During wear experiments, constant load and slide-roll ratio is frequently applied in tribo-tests beside other important parameters. Nevertheless, numerous studies demonstrated that constant slide-roll ratio is not accurate approach if TKR wear is modelled, while instead of a constant load, a flexion-angle dependent tibiofemoral force should be involved into the wear model to obtain realistic results. Methods A new analytical wear model, based upon Archard’s law, is introduced, which can determine the effect of the tibiofemoral force and the varying slide-roll on wear between the tibiofemoral connection under standard and non-standard squat movement. Results The calculated total wear with constant slide-roll during standard squat was 5.5 times higher compared to the reference value, while if total wear includes varying slide-roll during standard squat, the calculated wear was approximately 6.25 times higher. With regard to non-standard squat, total wear with constant slide-roll during standard squat was 4.16 times higher than the reference value. If total wear included varying slide-roll, the calculated wear was approximately 4.75 times higher. Conclusions It was demonstrated that the augmented force parameter solely caused 65% higher wear volume while the slide-roll ratio itself increased wear volume by 15% higher compared to the reference value. These results state that the force component has the major effect on wear propagation while non-standard squat should be proposed for TKR patients as rehabilitation exercise. PMID:29721453

  1. Total or Partial Knee Arthroplasty Trial - TOPKAT: study protocol for a randomised controlled trial

    PubMed Central

    2013-01-01

    Background In the majority of patients with osteoarthritis of the knee the disease originates in the medial compartment. There are two fundamentally different approaches to knee replacement for patients with unicompartmental disease: some surgeons feel that it is always best to replace both the knee compartments with a total knee replacement (TKR); whereas others feel it is best to replace just the damaged component of the knee using a partial or unicompartment replacement (UKR). Both interventions are established and well-documented procedures. Little evidence exists to prove the clinical and cost-effectiveness of either management option. This provides an explanation for the high variation in treatment of choice by individual surgeons for the same knee pathology. The aim of the TOPKAT study will be to assess the clinical and cost effectiveness of TKRs compared to UKRs in patients with medial compartment osteoarthritis. Methods/Design The design of the study is a single layer multicentre superiority type randomised controlled trial of unilateral knee replacement patients. Blinding will not be possible as the surgical scars for each procedure differ. We aim to recruit 500 patients from approximately 28 secondary care orthopaedic units from across the UK including district general and teaching hospitals. Participants will be randomised to either UKR or TKR. Randomisation will occur using a web-based randomisation system. The study is pragmatic in terms of implant selection for the knee replacement operation. Participants will be followed up for 5 years. The primary outcome is the Oxford Knee Score, which will be collected via questionnaires at 2 months, 1 year and then annually to 5 years. Secondary outcomes will include cost-effectiveness, patient satisfaction and complications data. Trial registration Current Controlled Trials ISRCTN03013488; ClinicalTrials.gov Identifier: NCT01352247 PMID:24028414

  2. Effect of body mass index on knee function outcomes following continuous passive motion in patients with osteoarthritis after total knee replacement: a retrospective study.

    PubMed

    Liao, C-D; Huang, Y-C; Chiu, Y-S; Liou, T-H

    2017-09-01

    Obesity may influence postoperative rehabilitation outcomes after total knee replacement (TKR). The aim of this study was to evaluate the effects of body mass index (BMI) on the progression of inpatient rehabilitation using continuous passive motion (CPM) and its treatment outcomes. A retrospective study was conducted in a rehabilitation centre. In total, 354 patients undergoing primary TKR were enrolled through medical chart review. All patients commenced the CPM programme immediately after surgery and continued until hospital discharge. Knee flexion, pain score, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) physical function score. Patients were divided into five BMI groups: normal weight (n=59), overweight (n=95), Class I obesity (n=90), Class II obesity (n=82) and Class III obesity (n=28). All outcome measures were recorded at admission; daily during the inpatient stay; at discharge; and at 1-, 3- and 6-month follow-up assessments. During CPM exercises, obese patients had a smaller initial flexion angle (P<0.001) and a smaller daily increment in the CPM motion arc (P<0.001) compared with patients of normal weight. Severe obesity was associated with poor knee flexion [adjusted odds ratio (aOR) 11.9, 95% confidence interval (CI) 3.49 to 40.94, P<0.001] and WOMAC physical function score (aOR 5.09, 95% CI 1.62 to 16.03, P=0.005) at 6-month follow-up. Obesity had a negative effect on progress during the CPM protocol, which commenced immediately after surgery and continued until discharge. Obesity was also associated with poorer self-reported function at 6-month follow-up. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  3. Are critical pathways and implant standardization programs effective in reducing costs in total knee replacement operations?

    PubMed

    Ho, David M; Huo, Michael H

    2007-07-01

    Total knee replacement (TKR) operation is one of the most effective procedures, both clinically and in terms of cost. Because of increased volume and cost for this procedure during the past 3 decades, TKRs are often targeted for cost reduction. The purpose of this study was to evaluate the efficacy of two cost reducing methodologies, establishment of critical clinical pathways, and standardization of implant costs. Ninety patients (90 knees) were randomly selected from a population undergoing primary TKR during a 2-year period at a tertiary teaching hospital. Patients were assigned to three groups that corresponded to different strategies implemented during the evolution of the joint-replacement program. Medical records were reviewed for type of anesthesia, operative time, length of stay, and any perioperative complications. Financial information for each patient was compared among the three groups. Data analysis demonstrated that the institution of a critical pathway significantly shortened length of hospital stay and was effective in reducing the hospital costs by 18% (p < 0.05). In addition, standardization of surgical techniques under the care of a single surgeon substantially reduced the operative time. Selection of implants from a single vendor did not have any substantial effect in additionally reducing the costs. Standardized postoperative management protocols and critical clinical pathways can reduce costs and operative time. Future efforts must focus on lowering the costs of the prostheses, particularly with competitive bidding or capitation of prostheses costs. Although a single-vendor approach was not effective in this study, it is possible that a cost reduction could have been realized if more TKRs were performed, because the pricing contract was based on projected volume of TKRs to be done by the hospital.

  4. Relationship between organizational factors and performance among pay-for-performance hospitals.

    PubMed

    Vina, Ernest R; Rhew, David C; Weingarten, Scott R; Weingarten, Jason B; Chang, John T

    2009-07-01

    The Centers for Medicare & Medicaid Services (CMS)/Premier Hospital Quality Incentive Demonstration (HQID) project aims to improve clinical performance through a pay-for-performance program. We conducted this study to identify the key organizational factors associated with higher performance. An investigator-blinded, structured telephone survey of eligible hospitals' (N = 92) quality improvement (QI) leaders was conducted among HQID hospitals in the top 2 or bottom 2 deciles submitting performance measure data from October 2004 to September 2005. The survey covered topics such as QI interventions, data feedback, physician leadership, support for QI efforts, and organizational culture. More top performing hospitals used clinical pathways for the treatment of AMI (49% vs. 15%, p < 0.01), HF (44% vs. 18%, p < 0.01), PN (38% vs. 13%, p < 0.01) and THR/TKR (56% vs. 23%, p < 0.01); organized into multidisciplinary teams to manage patients with AMI (93% vs. 77%, p < 0.05) and HF (93% vs. 69%, p < 0.01); used order sets for the treatment of THR/TKR (91% vs. 64%, p < 0.01); and implemented computerized physician order entry in the hospital (24.4% vs. 7.9%, p < 0.05). Finally, more top performers reported having adequate human resources for QI projects (p < 0.01); support of the nursing staff to increase adherence to quality indicators (p < 0.01); and an organizational culture that supported coordination of care (p < 0.01), pace of change (p < 0.01), willingness to try new projects (p < 0.01), and a focus on identifying system errors rather than blaming individuals (p < 0.05). Organizational structure, support, and culture are associated with high performance among hospitals participating in a pay-for-performance demonstration project. Multiple organizational factors remain important in optimizing clinical care.

  5. Early rehabilitation after total knee replacement surgery: a multicenter, noninferiority, randomized clinical trial comparing a home exercise program with usual outpatient care.

    PubMed

    Han, Annie S Y; Nairn, Lillias; Harmer, Alison R; Crosbie, Jack; March, Lyn; Parker, David; Crawford, Ross; Fransen, Marlene

    2015-02-01

    To determine, at 6 weeks postsurgery, if a monitored home exercise program (HEP) is not inferior to usual care rehabilitation for patients undergoing primary unilateral total knee replacement (TKR) surgery for osteoarthritis. We conducted a multicenter, randomized clinical trial. Patients ages 45-75 years were allocated at the time of hospital discharge to usual care rehabilitation (n = 196) or the HEP (n = 194). Outcomes assessed 6 weeks after surgery included the Western Ontario and McMaster Universities Osteoarthritis Index pain and physical function subscales, knee range of motion, and the 50-foot walk time. The upper bound of the 95% confidence interval (95% CI) mean difference favoring usual care was used to determine noninferiority. At 6 weeks after surgery there were no significant differences between usual care and HEP, respectively, for pain (7.4 and 7.2; 95% CI mean difference [MD] -0.7, 0.9), physical function (22.5 and 22.4; 95% CI MD -2.5, 2.6), knee flexion (96° and 97°; 95% CI MD -4°, 2°), knee extension (-7° and -6°; 95% CI MD -2°, 1°), or the 50-foot walk time (12.9 and 12.9 seconds; 95% CI MD -0.8, 0.7 seconds). At 6 weeks, 18 patients (9%) allocated to usual care and 11 (6%) to the HEP did not achieve 80° knee flexion. There was no difference between the treatment allocations in the number of hospital readmissions. The HEP was not inferior to usual care as an early rehabilitation protocol after primary TKR. Copyright © 2015 by the American College of Rheumatology.

  6. Greek Physiotherapists' Perspectives on Rehabilitation Following Total Knee Replacement: a Descriptive Survey.

    PubMed

    Moutzouri, Maria; Gleeson, Nigel; Billis, Evdokia; Tsepis, Elias; Gliatis, John

    2017-10-01

    In Greece, as in many countries, there is a scarcity of evidence in the type of physiotherapy services offered for the rehabilitation of total knee replacement (TKR). Despite the number of TKRs annually performed in Greece (over 10,000), there are no available clinical guidelines as to the content of best physiotherapy practice. The aim of this nationwide survey undertaken by physiotherapists treating TKR patients post-operatively was to record standard practice and services available in Greece. Design: cross-country survey Ten per cent of all registered physiotherapists working in public/private sectors were recruited. The developed survey comprised of questions regarding therapists' profile, protocols implemented at different stages of rehabilitation and the aims and modalities used. A 58.7% response rate was achieved, where 36% (47/132) of respondents were treating patients in the inpatient phase and 64% (85/132) after hospital discharge. Patients in Greece are discharged with a home-based exercise program (56.7%) and, to a lesser extent, are referred to rehabilitation centres (13.3%). Strengthening, range of movement and functionality seemed to be the primary goals especially in the inpatient phase, whereas in the outpatient phase, apart from the larger differences identified, functionality and balance training were more frequently reported. No significant variations in practice were found during inpatient rehabilitation, whilst there seemed to be diversity across outpatient physiotherapy programs. The current survey suggests that patient's general health and psychological and behavioural issues are the criteria by which physiotherapists select the volume of implemented exercise and progression. However, no specific guidelines were followed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Pain control after primary total knee replacement. A prospective randomised controlled trial of local infiltration versus single shot femoral nerve block.

    PubMed

    Ashraf, Anam; Raut, Videsh V; Canty, Stephen J; McLauchlan, George J

    2013-10-01

    We report a prospective blinded randomised trial of local infiltration versus femoral nerve block in patients undergoing primary total knee replacement (TKR), in accordance with the CONSORT statement 2010. Fifty patients in a teaching hospital were consented for the study. The study arms were intraoperative local anaesthesia (150ml 0.2% ropivacaine/1ml 1:1000 adrenaline/30mg ketolorac) and femoral nerve block (30ml 0.2% ropivacaine) with a primary outcome of pain score at 4h post operatively. Secondary outcomes were pain at 2h, pain scores before and after physiotherapy on day one, total opiate administered, time to physiotherapy goals and length of stay. Randomisation was by sealed envelope. The assessor was blinded and the patients partially blinded to the intervention. Ten patients were excluded, eight before randomisation. The trial is complete. Forty patients were analysed for the primary outcome measure. The local infiltration group had significantly lower pain scores at 4h post-operatively; mean [SD] score 2.1 [2.6] versus 6.8 [3.2], p<0.00001 and on post-operative day one prior to physiotherapy; mean score 2.4 [2.3] versus 4.4 [2.3], p<0.05. Total opiate use was also significantly lower in the local infiltration group; mean total 115 [50.3]mg versus 176.5 [103.5]mg, p<0.01. There was no difference in any other outcome. There were no harms as a result of either intervention. Intraoperative local infiltration gives superior pain relief compared to single shot femoral nerve block over the first 24h following primary TKR and minimises post-operative opiate use. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Multiple Objects Fusion Tracker Using a Matching Network for Adaptively Represented Instance Pairs

    PubMed Central

    Oh, Sang-Il; Kang, Hang-Bong

    2017-01-01

    Multiple-object tracking is affected by various sources of distortion, such as occlusion, illumination variations and motion changes. Overcoming these distortions by tracking on RGB frames, such as shifting, has limitations because of material distortions caused by RGB frames. To overcome these distortions, we propose a multiple-object fusion tracker (MOFT), which uses a combination of 3D point clouds and corresponding RGB frames. The MOFT uses a matching function initialized on large-scale external sequences to determine which candidates in the current frame match with the target object in the previous frame. After conducting tracking on a few frames, the initialized matching function is fine-tuned according to the appearance models of target objects. The fine-tuning process of the matching function is constructed as a structured form with diverse matching function branches. In general multiple object tracking situations, scale variations for a scene occur depending on the distance between the target objects and the sensors. If the target objects in various scales are equally represented with the same strategy, information losses will occur for any representation of the target objects. In this paper, the output map of the convolutional layer obtained from a pre-trained convolutional neural network is used to adaptively represent instances without information loss. In addition, MOFT fuses the tracking results obtained from each modality at the decision level to compensate the tracking failures of each modality using basic belief assignment, rather than fusing modalities by selectively using the features of each modality. Experimental results indicate that the proposed tracker provides state-of-the-art performance considering multiple objects tracking (MOT) and KITTIbenchmarks. PMID:28420194

  9. Methods for natural gas and heavy hydrocarbon co-conversion

    DOEpatents

    Kong, Peter C [Idaho Falls, ID; Nelson, Lee O [Idaho Falls, ID; Detering, Brent A [Idaho Falls, ID

    2009-02-24

    A reactor for reactive co-conversion of heavy hydrocarbons and hydrocarbon gases and includes a dielectric barrier discharge plasma cell having a pair of electrodes separated by a dielectric material and passageway therebetween. An inlet is provided for feeding heavy hydrocarbons and other reactive materials to the passageway of the discharge plasma cell, and an outlet is provided for discharging reaction products from the reactor. A packed bed catalyst may optionally be used in the reactor to increase efficiency of conversion. The reactor can be modified to allow use of a variety of light sources for providing ultraviolet light within the discharge plasma cell. Methods for upgrading heavy hydrocarbons are also disclosed.

  10. Nonthermal plasma systems and methods for natural gas and heavy hydrocarbon co-conversion

    DOEpatents

    Kong, Peter C.; Nelson, Lee O.; Detering, Brent A.

    2005-05-24

    A reactor for reactive co-conversion of heavy hydrocarbons and hydrocarbon gases and includes a dielectric barrier discharge plasma cell having a pair of electrodes separated by a dielectric material and passageway therebetween. An inlet is provided for feeding heavy hydrocarbons and other reactive materials to the passageway of the discharge plasma cell, and an outlet is provided for discharging reaction products from the reactor. A packed bed catalyst may optionally be used in the reactor to increase efficiency of conversion. The reactor can be modified to allow use of a variety of light sources for providing ultraviolet light within the discharge plasma cell. Methods for upgrading heavy hydrocarbons are also disclosed.

  11. A linear polarization converter with near unity efficiency in microwave regime

    NASA Astrophysics Data System (ADS)

    Xu, Peng; Wang, Shen-Yun; Geyi, Wen

    2017-04-01

    In this paper, we present a linear polarization converter in the reflective mode with near unity conversion efficiency. The converter is designed in an array form on the basis of a pair of orthogonally arranged three-dimensional split-loop resonators sharing a common terminal coaxial port and a continuous metallic ground slab. It converts the linearly polarized incident electromagnetic wave at resonance to its orthogonal counterpart upon the reflection mode. The conversion mechanism is explained by an equivalent circuit model, and the conversion efficiency can be tuned by changing the impedance of the terminal port. Such a scheme of the linear polarization converter has potential applications in microwave communications, remote sensing, and imaging.

  12. Performance of a Prototype Stationary Catadioptric Concentrating Photovoltaic Module

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lloyd, John V.; Kozodoy, Peter; Gladden, Christopher

    A stationary catadioptric concentrating photovoltaic module with aperture area over 100 cm2, geometric concentration of 180x, and collection within 60° of polar incidence was designed, prototyped, and characterized. The module performance followed modeling closely with a peak power conversion efficiency of 26% for direct irradiance. Tracking of the sun is accomplished via translational micro-tracking completely internal to the module, avoiding the cost and complexity of mechanical two-axis trackers that point towards the sun. This study demonstrates the potential for concentrating photovoltaic modules with significantly higher efficiency than industry standard silicon photovoltaic modules that could be installed in stationary configurations onmore » rooftops.« less

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atanov, N.; et al.

    The Mu2e experiment at Fermilab will search for the coherentmore » $$\\mu \\to e$$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.« less

  14. Performance of a Prototype Stationary Catadioptric Concentrating Photovoltaic Module

    DOE PAGES

    Lloyd, John V.; Kozodoy, Peter; Gladden, Christopher; ...

    2018-03-28

    A stationary catadioptric concentrating photovoltaic module with aperture area over 100 cm2, geometric concentration of 180x, and collection within 60° of polar incidence was designed, prototyped, and characterized. The module performance followed modeling closely with a peak power conversion efficiency of 26% for direct irradiance. Tracking of the sun is accomplished via translational micro-tracking completely internal to the module, avoiding the cost and complexity of mechanical two-axis trackers that point towards the sun. This study demonstrates the potential for concentrating photovoltaic modules with significantly higher efficiency than industry standard silicon photovoltaic modules that could be installed in stationary configurations onmore » rooftops.« less

  15. An inverse problem for Gibbs fields with hard core potential

    NASA Astrophysics Data System (ADS)

    Koralov, Leonid

    2007-05-01

    It is well known that for a regular stable potential of pair interaction and a small value of activity one can define the corresponding Gibbs field (a measure on the space of configurations of points in Rd). In this paper we consider a converse problem. Namely, we show that for a sufficiently small constant ρ¯1 and a sufficiently small function ρ¯2(x), x ∈Rd, that is equal to zero in a neighborhood of the origin, there exist a hard core pair potential and a value of activity such that ρ¯1 is the density and ρ¯2 is the pair correlation function of the corresponding Gibbs field.

  16. Unity-Efficiency Parametric Down-Conversion via Amplitude Amplification.

    PubMed

    Niu, Murphy Yuezhen; Sanders, Barry C; Wong, Franco N C; Shapiro, Jeffrey H

    2017-03-24

    We propose an optical scheme, employing optical parametric down-converters interlaced with nonlinear sign gates (NSGs), that completely converts an n-photon Fock-state pump to n signal-idler photon pairs when the down-converters' crystal lengths are chosen appropriately. The proof of this assertion relies on amplitude amplification, analogous to that employed in Grover search, applied to the full quantum dynamics of single-mode parametric down-conversion. When we require that all Grover iterations use the same crystal, and account for potential experimental limitations on crystal-length precision, our optimized conversion efficiencies reach unity for 1≤n≤5, after which they decrease monotonically for n values up to 50, which is the upper limit of our numerical dynamics evaluations. Nevertheless, our conversion efficiencies remain higher than those for a conventional (no NSGs) down-converter.

  17. Two Trackers Are Better than One: Information about the Co-actor's Actions and Performance Scores Contribute to the Collective Benefit in a Joint Visuospatial Task.

    PubMed

    Wahn, Basil; Kingstone, Alan; König, Peter

    2017-01-01

    When humans collaborate, they often distribute task demands in order to reach a higher performance compared to performing the same task alone (i.e., a collective benefit). Here, we tested to what extent receiving information about the actions of a co-actor, performance scores, or receiving both types of information impacts the collective benefit in a collaborative multiple object tracking task. In a between-subject design, pairs of individuals jointly tracked a subset of target objects among several moving distractor objects on a computer screen for a 100 trials. At the end of a trial, pairs received performance scores (Experiment 1), information about their partner's target selections (Experiment 2), or both types of information (Experiment 3). In all experiments, the performance of the pair exceeded the individual performances and the simulated performance of two independent individuals combined. Initially, when receiving both types of information (Experiment 3), pairs achieved the highest performance and divided task demands most efficiently compared to the other two experiments. Over time, performances and the ability to divide task demands for pairs receiving a single type of information converged with those receiving both, suggesting that pairs' coordination strategies become equally effective over time across experiments. However, pairs' performances never reached a theoretical limit of performance in all experiments. For distributing task demands, members of a pair predominantly used a left-right division of labor strategy (i.e., the leftmost targets were tracked by one co-actor while the rightmost targets were tracked by the other co-actor). Overall, findings of the present study suggest that receiving information about actions of a co-actor, performance scores, or receiving both enables pairs to devise effective division of labor strategies in a collaborative visuospatial task. However, when pairs had both types of information available, the formation of division of labor strategies was facilitated, indicating that pairs benefited the most from having both types of information available (i.e., actions about the co-actor and performance scores). Findings are applicable to circumstances in which humans need to perform collaborative visuospatial tasks that are time-critical and/or only allow a very limited exchange of information between co-actors.

  18. Dual Oculometer System for Aviation Crew Assessment

    NASA Technical Reports Server (NTRS)

    Latorella, Kara; Ellis, Kyle K.; Lynn, William A.; Frasca, Dennis; Burdette, Daniel W.; Feigh, Charles T.; Douglas, Alan L.

    2010-01-01

    Oculometers, eye trackers, are a useful tool for ascertaining the manner in which pilots deploy visual attentional resources, and for assessing the degree to which stimuli capture attention exogenously. The aim of this effort was to obtain oculometer data comfortably, unobtrusively, reliably and with good spatial resolution over a standard B757-like flight deck for both individuals in a crew. We chose to implement two remote, 5-camera Smarteye systems which were crafted for this purpose to operate harmoniously. We present here the results of validation exercises, lessons learned for improving data quality, and initial thoughts on the use of paired oculometer data to reflect crew workload, coordination, and situation awareness, in the aggregate.

  19. Design and status of the Mu2e electromagnetic calorimeter

    DOE PAGES

    Atanov, N.; Baranov, V.; Budagov, J.; ...

    2015-10-02

    Here, the Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10 –17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order tomore » match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF 2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D; studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.« less

  20. Effect of hang cleans or squats paired with countermovement vertical jumps on vertical displacement.

    PubMed

    Andrews, Tedi R; Mackey, Theresa; Inkrott, Thomas A; Murray, Steven R; Clark, Ida E; Pettitt, Robert W

    2011-09-01

    Complex training is characterized by pairing resistance exercise with plyometric exercise to exploit the postactivation potentiation (PAP) phenomenon, thereby promising a better training effect. Studies on PAP as measured by human power performances are equivocal. One issue may be the lack of analyses across multiple sets of paired exercises, a common practice used by athletes. We evaluated countermovement vertical jump (CMJ) performance in 19 women, collegiate athletes in 3 of the following trials: (a) CMJs-only, where 1 set of CMJs served as a conditioning exercise, (b) heavy-load, back squats paired with CMJs, and (c) hang cleans paired with CMJs. The CMJ vertical displacement (3-attempt average), as measured with digital video, served as the dependent variable of CMJ performance. Across 3 sets of paired-exercise regimens, CMJ-only depreciated 1.6 cm and CMJ paired with back squats depreciated 2.0 cm (main effect, p < 0.05). Conversely, CMJ paired with hang cleans depreciated 0.30 cm (interaction, p < 0.05). Thus, the best complex training scheme was achieved by pairing CMJs with hang cleans in comparison to back squats or CMJs in and of themselves. Future research on exercise modes of complex training that best help athletes preserve and train with the highest power possible, in a given training session, is warranted.

  1. Nonreciprocal Single Photon Frequency Conversion via Chiral Coupling between a V-Type System and a Pair of Waveguides

    NASA Astrophysics Data System (ADS)

    Shi, Ce; Cheng, Mu-Tian; Ma, Xiao-San; Wang, Dong; Huang, Xianshan; Wang, Bing; Zhang, Jia-Yan

    2018-05-01

    Not Available Supported by the Anhui Provincial Natural Science Foundation under Grant No 1608085MA09, and the National Natural Science Foundation of China under Grant Nos 11774262, 61675006, 11474003 and 61472282.

  2. Performance of electron reconstruction and selection with the CMS detector in proton-proton collisions at √s = 8  TeV

    DOE PAGES

    Khachatryan, V.

    2015-06-10

    The performance and strategies used in electron reconstruction and selection at CMS are presented based on data corresponding to an integrated luminosity of 19.7 fb -1, collected in proton-proton collisions at √s = 8 TeV at the CERN LHC. The paper focuses on prompt isolated electrons with transverse momenta ranging from about 5 to a few 100 GeV. A detailed description is given of the algorithms used to cluster energy in the electromagnetic calorimeter and to reconstruct electron trajectories in the tracker. The electron momentum is estimated by combining the energy measurement in the calorimeter with the momentum measurement inmore » the tracker. Benchmark selection criteria are presented, and their performances assessed using Z, Υ, and J/ψ decays into e ++ e - pairs. The spectra of the observables relevant to electron reconstruction and selection as well as their global efficiencies are well reproduced by Monte Carlo simulations. The momentum scale is calibrated with an uncertainty smaller than 0.3%. The momentum resolution for electrons produced in Z boson decays ranges from 1.7 to 4.5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material.« less

  3. Tritium-field betacells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walko, R.J.; Lincoln, R.C.; Baca, W.E.

    1991-01-01

    Betavoltaic power sources operate by converting the nuclear decay energy of beta-emitting radioisotopes into electricity. Since they are not chemically driven, they could operate at temperatures which would either be to hot or too cold for typical chemical batteries. Further, for long lived isotopes, they offer the possibility of multi-decade active lifetimes. Two approaches are being investigated: direct and indirect conversion. Direct conversion cells consist of semiconductor diodes similar to photovoltaic cells. Beta particle directly bombard these cells, generating electron-hole pairs in the semiconductor which are converted to useful power. Many using low power flux beta emitters, wide bandgap semiconductorsmore » are required to achieve useful conversion efficiencies. The combination of tritium, as the beta emitter, and gallium phosphide (GaP), as the semiconductor converter, was evaluated. Indirect conversion betacells first convert the beta energy to light with a phosphor, and then to electricity with photovoltaic cells. An indirect conversion power source using a tritium radioluminescent (RL) light is being investigated. Our analysis indicates that this approach has the potential for significant volume and cost savings over the direct conversion method. 7 refs., 11 figs.« less

  4. Tritium-field betacells

    NASA Astrophysics Data System (ADS)

    Walko, R. J.; Lincoln, R. C.; Baca, W. E.; Goods, S. H.; Negley, G. H.

    Betavoltaic power sources operate by converting the nuclear decay energy of beta-emitting radioisotopes into electricity. Since they are not chemically driven, they could operate at temperatures which would either be too hot or too cold for typical chemical batteries. Further, for long lived isotopes, they offer the possibility of multi-decade active lifetimes. Two approaches are being investigated: direct and indirect conversion. Direct conversion cells consist of semiconductor diodes similar to photovoltaic cells. Beta particle directly bombard these cells, generating electron-hole pairs in the semiconductor which are converted to useful power. When using low power flux beta emitters, wide bandgap semiconductors are required to achieve useful conversion efficiencies. The combination of tritium, as the beta emitter, and gallium phosphide (GaP), as the semiconductor converter, was evaluated. Indirect conversion betacells first convert the beta energy to light with a phosphor, and then to electricity with photovoltaic cells. An indirect conversion power source using a tritium radioluminescent (RL) light is being investigated. Our analysis indicates that this approach has the potential for significant volume and cost savings over the direct conversion method.

  5. Semi-automatic engineering and tailoring of high-efficiency Bragg-reflection waveguide samples for quantum photonic applications

    NASA Astrophysics Data System (ADS)

    Pressl, B.; Laiho, K.; Chen, H.; Günthner, T.; Schlager, A.; Auchter, S.; Suchomel, H.; Kamp, M.; Höfling, S.; Schneider, C.; Weihs, G.

    2018-04-01

    Semiconductor alloys of aluminum gallium arsenide (AlGaAs) exhibit strong second-order optical nonlinearities. This makes them prime candidates for the integration of devices for classical nonlinear optical frequency conversion or photon-pair production, for example, through the parametric down-conversion (PDC) process. Within this material system, Bragg-reflection waveguides (BRW) are a promising platform, but the specifics of the fabrication process and the peculiar optical properties of the alloys require careful engineering. Previously, BRW samples have been mostly derived analytically from design equations using a fixed set of aluminum concentrations. This approach limits the variety and flexibility of the device design. Here, we present a comprehensive guide to the design and analysis of advanced BRW samples and show how to automatize these tasks. Then, nonlinear optimization techniques are employed to tailor the BRW epitaxial structure towards a specific design goal. As a demonstration of our approach, we search for the optimal effective nonlinearity and mode overlap which indicate an improved conversion efficiency or PDC pair production rate. However, the methodology itself is much more versatile as any parameter related to the optical properties of the waveguide, for example the phasematching wavelength or modal dispersion, may be incorporated as design goals. Further, we use the developed tools to gain a reliable insight in the fabrication tolerances and challenges of real-world sample imperfections. One such example is the common thickness gradient along the wafer, which strongly influences the photon-pair rate and spectral properties of the PDC process. Detailed models and a better understanding of the optical properties of a realistic BRW structure are not only useful for investigating current samples, but also provide important feedback for the design and fabrication of potential future turn-key devices.

  6. biobambam: tools for read pair collation based algorithms on BAM files

    PubMed Central

    2014-01-01

    Background Sequence alignment data is often ordered by coordinate (id of the reference sequence plus position on the sequence where the fragment was mapped) when stored in BAM files, as this simplifies the extraction of variants between the mapped data and the reference or of variants within the mapped data. In this order paired reads are usually separated in the file, which complicates some other applications like duplicate marking or conversion to the FastQ format which require to access the full information of the pairs. Results In this paper we introduce biobambam, a set of tools based on the efficient collation of alignments in BAM files by read name. The employed collation algorithm avoids time and space consuming sorting of alignments by read name where this is possible without using more than a specified amount of main memory. Using this algorithm tasks like duplicate marking in BAM files and conversion of BAM files to the FastQ format can be performed very efficiently with limited resources. We also make the collation algorithm available in the form of an API for other projects. This API is part of the libmaus package. Conclusions In comparison with previous approaches to problems involving the collation of alignments by read name like the BAM to FastQ or duplication marking utilities our approach can often perform an equivalent task more efficiently in terms of the required main memory and run-time. Our BAM to FastQ conversion is faster than all widely known alternatives including Picard and bamUtil. Our duplicate marking is about as fast as the closest competitor bamUtil for small data sets and faster than all known alternatives on large and complex data sets.

  7. Defect engineering of the oxygen-vacancy clusters formation in electron irradiated silicon by isovalent doping: An infrared perspective

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Sgourou, E. N.; Chroneos, A.

    2012-12-01

    Infrared spectroscopy was used to study the production and evolution of oxygen-vacancy (VOn for n = 1, 2, 3 and VmO for m = 1, 2, 3) clusters, in electron-irradiated Czochralski silicon (Cz-Si) samples, doped with isovalent dopants. It was determined that the production of the VO pair is enhanced in Ge-doped Si but is suppressed in Sn and Pb-doped Si. The phenomenon is discussed in terms of the competition between isovalent dopants and oxygen atoms in capturing vacancies in the course of irradiation. In the case of Ge, only transient GeV pairs form, leading finally to an increase of the VO production. Conversely, for Sn and Pb the corresponding pairs with vacancies are stable, having an opposite impact on the formation of VO pairs. Regarding V2O and V3O clusters, our measurements indicate that Ge doping enhances their formation, although Sn and Pb dopants suppress it. Similar arguments as those for the VO pair could be put forward, based on the effect of isovalent impurities on the availability of vacancies. Additionally, it was found that the conversion ratio of VO to VO2 decreases as the covalent radius of the isovalent dopant increases. These results are discussed in terms of the local strains introduced by the isovalent dopants in the Si lattice. These local strains affect the balance of the intrinsic defects created as a result of irradiation, as well as the balance between the two main reactions (VO + Oi → VO2 and VO + SiI → Oi) participating in the VO annealing, leading finally to a decrease of the VO2 production. The larger the covalent radius of the isovalent dopant (rGe < rSn < rPb), the larger the introduced strains in the lattice and then the less the VO2 formation in accordance with our experimental results. Interestingly, an opposite trend was observed for the conversion ratio of VO2 to VO3. The phenomenon is attributed to the enhanced diffusivity of oxygen impurity as a result of the presence of isovalent dopants, leading to an enhanced formation of the VO3 cluster. The results indicate that isovalent doping of Si is an effective way to control the formation of the deleterious oxygen-vacancy clustering that can affect Si-based devices.

  8. Time-bin entangled photon pairs from spontaneous parametric down-conversion pumped by a cw multi-mode diode laser.

    PubMed

    Kwon, Osung; Park, Kwang-Kyoon; Ra, Young-Sik; Kim, Yong-Su; Kim, Yoon-Ho

    2013-10-21

    Generation of time-bin entangled photon pairs requires the use of the Franson interferometer which consists of two spatially separated unbalanced Mach-Zehnder interferometers through which the signal and idler photons from spontaneous parametric down-conversion (SPDC) are made to transmit individually. There have been two SPDC pumping regimes where the scheme works: the narrowband regime and the double-pulse regime. In the narrowband regime, the SPDC process is pumped by a narrowband cw laser with the coherence length much longer than the path length difference of the Franson interferometer. In the double-pulse regime, the longitudinal separation between the pulse pair is made equal to the path length difference of the Franson interferometer. In this paper, we propose another regime by which the generation of time-bin entanglement is possible and demonstrate the scheme experimentally. In our scheme, differently from the previous approaches, the SPDC process is pumped by a cw multi-mode (i.e., short coherence length) laser and makes use of the coherence revival property of such a laser. The high-visibility two-photon Franson interference demonstrates clearly that high-quality time-bin entanglement source can be developed using inexpensive cw multi-mode diode lasers for various quantum communication applications.

  9. Absence of the preemptive analgesic effect of dextromethorphan in total knee replacement under epidural anesthesia.

    PubMed

    Yeh, C C; Ho, S T; Kong, S S; Wu, C T; Wong, C S

    2000-12-01

    Previous studies have shown that dextromethorphan (DM), a N-methyl-D-aspartate (NMDA) receptor antagonist, produces a preemptive analgesic effect on post-operative pain. The aim of this study was to further examine the preemptive analgesic effect of intramuscular (i.m.) DM injection on unilateral total knee replacement (TKR). Sixty-four ASA I-III patients scheduled for unilateral TKR surgery were randomly allocated into three groups in a prospective double-blind manner. All patients received epidural anesthesia without any premedication. An initial bolus dose of 2% lidocaine (15-20 mL) followed by a maintenance dose of 8-10 mL/h was decided. Fentanyl (1.5 micrograms/kg) and diazepam (2 mg) were given i.v. before epidural catheter insertion. The epidural catheter was placed via the L2-L3 or L3-L4 interspace and advanced for 5 cm cephalad [corrected]. Patients received i.m. injection of 20 mg chlorpheniramine (CPM) before surgery as control (group C, n = 22). For the study groups, patients were given an i.m. injection containing 40 mg DM and 20 mg CPM, before (group B, n = 22) or after surgery (group A, n = 20), respectively. Postoperation, patients received intravenous morphine by means of a patient controlled analgesia (PCA) device for pain relief. The time to the first pull of PCA trigger, morphine consumption, worse pain scores (resting and incidental), and analgesics related side effects were recorded at 1, 2, 4, 8, 24, 48 and 72 h after surgery. The time from the end of operation to the first PCA trigger were 31.2 +/- 5.2 min in group C, 67.3 +/- 11.1 min in group B (P < 0.05, compared with group C) and 61.8 +/- 7.2 min in group A (P < 0.05, compared with group C) respectively. The relevant pain score at resting, observed at the 8 h postoperatively was respectively 4.2 +/- 0.1 in group C, 3.7 +/- 0.2 in group B (P < 0.05, compared with group C) and 3.4 +/- 0.2 in group A (P < 0.05, compared with group C); and at the 24 h was 3.1 +/- 0.2 in group C, 2.4 +/- 0.2 in group B (P < 0.05, compared with group C) and 2.5 +/- 0.1 in group A (P < 0.05, compared with group C) respectively. There were no significant differences in actual morphine delivery and frequency of PCA triggering at all time among the three groups. Moreover, there was also no significant statistic difference in morphine-associated side effects among the three groups. In the present study, we failed to observe any preemptive analgesic effect of DM (40 mg, i.m.) on postoperative pain in patients who received TKR under epidural anesthesia, however, DM given either before or after surgery augmented other analgesic (morphine) to offer a better pain relief.

  10. Chapter 6: CPV Tracking and Trackers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luque-Heredia, Ignacio; Magalhaes, Pedro; Muller, Matthew

    2016-04-15

    This chapter explains the functional requirements of a concentrator photovoltaic (CPV) sun tracker. It derives the design specifications of a CPV tracker. The chapter presents taxonomy of trackers describing the most common tracking architectures, based on the number of axes, their relative position, and the foundation and placing of tracking drives. It deals with the structural issues related to tracker design, mainly related to structural flexure and its impact on the system's acceptance angle. The chapter analyzes the auto-calibrated sun tracking control, by describing the state of the art and its development background. It explores the sun tracking accuracy measurementmore » with a practical example. The chapter discusses tracker manufacturing and tracker field works. It reviews survey of different types of tracker designs obtained from different manufacturers. Finally, the chapter deals with IEC62817, the technical standard developed for CPV sun trackers.« less

  11. Bi-stable frequency up-conversion piezoelectric energy harvester driven by non-contact magnetic repulsion

    NASA Astrophysics Data System (ADS)

    Tang, Q. C.; Yang, Y. L.; Li, Xinxin

    2011-12-01

    This paper presents miniaturized energy harvesters, where the frequency up-conversion technique is used to improve the bandwidth of vibration energy harvesters. The proposed and developed miniature piezoelectric energy harvester utilizes magnetic repulsion forces to achieve non-contact frequency up-conversion, thereby avoiding mechanical collision and wear for long-term working durability. A pair of piezoelectric resonant cantilevers is micro-fabricated to generate electric power. A simplified model involving linear oscillators and magnetic interaction is deployed to demonstrate the feasibility of the device design. A bench-top harvester has been fabricated and characterized, resulting in average power generation of over 10 µW within a broad frequency range of 10-22 Hz under 1g acceleration.

  12. Joint temporal density measurements for two-photon state characterization.

    PubMed

    Kuzucu, Onur; Wong, Franco N C; Kurimura, Sunao; Tovstonog, Sergey

    2008-10-10

    We demonstrate a technique for characterizing two-photon quantum states based on joint temporal correlation measurements using time-resolved single-photon detection by femtosecond up-conversion. We measure for the first time the joint temporal density of a two-photon entangled state, showing clearly the time anticorrelation of the coincident-frequency entangled photon pair generated by ultrafast spontaneous parametric down-conversion under extended phase-matching conditions. The new technique enables us to manipulate the frequency entanglement by varying the down-conversion pump bandwidth to produce a nearly unentangled two-photon state that is expected to yield a heralded single-photon state with a purity of 0.88. The time-domain correlation technique complements existing frequency-domain measurement methods for a more complete characterization of photonic entanglement.

  13. Hydrogen adsorption on two catalysts for the ortho- to parahydrogen conversion: Cr-doped silica and ferric oxide gel.

    PubMed

    Hartl, Monika; Gillis, Robert Chad; Daemen, Luke; Olds, Daniel P; Page, Katherine; Carlson, Stefan; Cheng, Yongqiang; Hügle, Thomas; Iverson, Erik B; Ramirez-Cuesta, A J; Lee, Yongjoong; Muhrer, Günter

    2016-06-29

    Molecular hydrogen exists in two spin-rotation coupled states: parahydrogen and orthohydrogen. Due to the variation of energy with rotational level, the occupation of ortho- and parahydrogen states is temperature dependent, with parahydrogen being the dominant species at low temperatures. The equilibrium at 20 K (99.8% parahydrogen) can be reached by natural conversion only after a lengthy process. With the use of a suitable catalyst, this process can be shortened significantly. Two types of commercial catalysts currently being used for ortho- to parahydrogen conversion are: iron(iii) oxide (Fe2O3, IONEX®), and chromium(ii) oxide doped silica catalyst (CrO·SiO2, OXISORB®). We investigate the interaction of ortho- and parahydrogen with the surfaces of these ortho-para conversion catalysts using neutron vibrational spectroscopy. The catalytic surfaces have been characterized using X-ray absorption fine structure (XAFS) and X-ray/neutron pair distribution function measurements.

  14. Probing the photon polarization in B → K*γ with conversion

    DOE PAGES

    Bishara, Fady; Robinson, Dean J.

    2015-09-02

    We re-examine the possibility to measure the photon polarization in B → K*γ decays, via decays in which the photon subsequently undergoes nuclear conversion to a lepton pair. We obtain compact expressions for the full decay-plus-conversion amplitude. With these results we show that interference between the B → (K* → Kπ)γ decay and the γN → ℓ + ℓ – N conversion permits both the ratio and relative weak phase between the left- and right-handed photon amplitudes to be probed by an angular observable, constructed from the final state dilepton, kaon and pion kinematic configuration. Exploiting this technique will bemore » experimentally challenging. However, we present special kinematic cuts that enhance the statistical power of this technique by an O(1) factor. Furthermore, we verify this effect and extract pertinent angular kinematic distributions with dedicated numerical simulations.« less

  15. Magnetic field effect in fluorescence of excited fluorophore equilibrated with exciplex that reversibly dissociates into radical-ion pair undergoing the spin conversion.

    PubMed

    Dodin, Dmitry V; Ivanov, Anatoly I; Burshtein, Anatoly I

    2012-07-14

    The fluorescence of the photoexcited electron acceptor, (1)A∗, and the exciplex, (1)[D(+δ)A(-δ)] formed at contact of (1)A∗ with an electron donor (1)D, is known to be very sensitive to a magnetic field, assisting the spin conversion in the resulting geminate radical ion pair (RIP), (1, 3)[D(+)...A(-)]. The relative increase of the fluorescence in the highest magnetic field compared to the lowest one, known as the magnetic field effect, crucially depends on the dielectric constant of the solvent, ɛ. This phenomenon first studied experimentally is at first reproduced here theoretically by means of the so called integral encounter theory. It was shown to be very sensitive to the position of the exciplex energy level relative to the levels of exciplex precursors and the charged products of its dissociation. The results obtained strongly depend on the dielectric properties of the solvents as well as on the exciplex and RIP formation rates.

  16. Hyperfine interaction mechanism of magnetic field effects in sequential fluorophore and exciplex fluorescence.

    PubMed

    Dodin, Dmitry V; Ivanov, Anatoly I; Burshtein, Anatoly I

    2013-03-28

    The magnetic field effect on the fluorescence of the photoexcited electron acceptor, (1)A∗, and the exciplex, (1)[D(+δ)A(-δ)] formed at contact of (1)A∗ with an electron donor (1)D, is theoretically explored in the framework of Integral Encounter Theory. It is assumed that the excited fluorophore is equilibrated with the exciplex that reversibly dissociates into the radical-ion pair. The magnetic field sensitive stage is the spin conversion in the resulting geminate radical-ion pair, (1, 3)[D(+)...A(-)] that proceeds due to hyperfine interaction. We confirm our earlier conclusion (obtained with a rate description of spin conversion) that in the model with a single nucleus spin 1/2 the magnitude of the Magnetic Field Effect (MFE) also vanishes in the opposite limits of low and high dielectric permittivity of the solvent. Moreover, it is shown that MFE being positive at small hyperfine interaction A, first increases with A but approaching the maximum starts to decrease and even changes the sign.

  17. Communicating with sentences: A multi-word naming game model

    NASA Astrophysics Data System (ADS)

    Lou, Yang; Chen, Guanrong; Hu, Jianwei

    2018-01-01

    Naming game simulates the process of naming an object by a single word, in which a population of communicating agents can reach global consensus asymptotically through iteratively pair-wise conversations. We propose an extension of the single-word model to a multi-word naming game (MWNG), simulating the case of describing a complex object by a sentence (multiple words). Words are defined in categories, and then organized as sentences by combining them from different categories. We refer to a formatted combination of several words as a pattern. In such an MWNG, through a pair-wise conversation, it requires the hearer to achieve consensus with the speaker with respect to both every single word in the sentence as well as the sentence pattern, so as to guarantee the correct meaning of the saying; otherwise, they fail reaching consensus in the interaction. We validate the model in three typical topologies as the underlying communication network, and employ both conventional and man-designed patterns in performing the MWNG.

  18. LysoTracker and MitoTracker Red are transport substrates of P-glycoprotein: implications for anticancer drug design evading multidrug resistance.

    PubMed

    Zhitomirsky, Benny; Farber, Hodaya; Assaraf, Yehuda G

    2018-04-01

    LysoTracker and MitoTracker Red are fluorescent probes widely used for viable cell staining of lysosomes and mitochondria, respectively. They are utilized to study organelle localization and their resident proteins, assess organelle functionality and quantification of organelle numbers. The ATP-driven efflux transporter P-glycoprotein (P-gp) is expressed in normal and malignant tissues and extrudes structurally distinct endogenous and exogenous cytotoxic compounds. Thus, once aromatic hydrophobic compounds such as the above-mentioned fluorescent probes are recognized as transport substrates, efflux pumps including P-gp may abolish their ability to reach their cellular target organelles. Herein, we show that LysoTracker and MitoTracker Red are expelled from P-gp-overexpressing cancer cells, thus hindering their ability to fluorescently mark target organelles. We further demonstrate that tariquidar, a potent P-gp transport inhibitor, restores LysoTracker and MitoTracker Red cell entry. We conclude that LysoTracker and MitoTracker Red are P-gp transport substrates, and therefore, P-gp expression must be taken into consideration prior to cellular applications using these probes. Importantly, as MitoTracker was a superior P-gp substrate than LysoTracker Red, we discuss the implications for the future design of chemotherapeutics evading cancer multidrug resistance. Furthermore, restoration of MitoTracker Red fluorescence in P-gp-overexpressing cells may facilitate the identification of potent P-gp transport inhibitors (i.e. chemosensitizers). © 2018 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  19. Effects of mobile phone distraction on pedestrians' crossing behavior and visual attention allocation at a signalized intersection: An outdoor experimental study.

    PubMed

    Jiang, Kang; Ling, Feiyang; Feng, Zhongxiang; Ma, Changxi; Kumfer, Wesley; Shao, Chen; Wang, Kun

    2018-06-01

    With the rapid growth in mobile phone use worldwide, traffic safety experts have begun to consider the impact of mobile phone distractions on pedestrian crossing safety. This study sought to investigate how mobile phone distractions (music distraction, phone conversation distraction and text distraction) affect the behavior of pedestrians while they are crossing the street. An outdoor-environment experiment was conducted among 28 college student pedestrians. Two HD videos and an eye tracker were employed to record and analyze crossing behavior and visual attention allocation. The results of the research showed that the three mobile phone distractions cause different levels of impairment to pedestrians' crossing performance, with the greatest effect from text distraction, followed by phone conversation distraction and music distraction. Pedestrians distracted by music initiate crossing later, have increased pupil diameter, and reduce their scanning frequency, fixation points and fixation times toward traffic signal area priorities. In addition to the above effects, pedestrians distracted by phone conversation cross the street more slowly, direct fewer fixation points to the right traffic area, and spend less fixation time and lower average fixation duration on the left traffic area. Moreover, pedestrians distracted by texting look left and right less often and switch, distribute and maintain less visual attention on the traffic environment. These findings may inform researchers, policy makers, and pedestrians. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Using others' words: conversational use of reported speech by individuals with aphasia and their communication partners.

    PubMed

    Hengst, Julie A; Frame, Simone R; Neuman-Stritzel, Tiffany; Gannaway, Rachel

    2005-02-01

    Reported speech, wherein one quotes or paraphrases the speech of another, has been studied extensively as a set of linguistic and discourse practices. Researchers agree that reported speech is pervasive, found across languages, and used in diverse contexts. However, to date, there have been no studies of the use of reported speech among individuals with aphasia. Grounded in an interactional sociolinguistic perspective, the study presented here documents and analyzes the use of reported speech by 7 adults with mild to moderately severe aphasia and their routine communication partners. Each of the 7 pairs was videotaped in 4 everyday activities at home or around the community, yielding over 27 hr of conversational interaction for analysis. A coding scheme was developed that identified 5 types of explicitly marked reported speech: direct, indirect, projected, indexed, and undecided. Analysis of the data documented reported speech as a common discourse practice used successfully by the individuals with aphasia and their communication partners. All participants produced reported speech at least once, and across all observations the target pairs produced 400 reported speech episodes (RSEs), 149 by individuals with aphasia and 251 by their communication partners. For all participants, direct and indirect forms were the most prevalent (70% of RSEs). Situated discourse analysis of specific episodes of reported speech used by 3 of the pairs provides detailed portraits of the diverse interactional, referential, social, and discourse functions of reported speech and explores ways that the pairs used reported speech to successfully frame talk despite their ongoing management of aphasia.

  1. Can a Free Wearable Activity Tracker Change Behavior? The Impact of Trackers on Adults in a Physician-Led Wellness Group.

    PubMed

    Gualtieri, Lisa; Rosenbluth, Sandra; Phillips, Jeffrey

    2016-11-30

    Wearable activity trackers (trackers) are increasingly popular devices used to track step count and other health indicators. Trackers have the potential to benefit those in need of increased physical activity, such as adults who are older and face significant health challenges. These populations are least likely to purchase trackers and most likely to face challenges in using them, yet may derive educational, motivational, and health benefits from their use once these barriers are removed. The aim of this pilot research is to investigate the use of trackers by adults with chronic medical conditions who have never used trackers previously. Specifically, we aim to determine (1) if participants would accept and use trackers to increase their physical activity; (2) if there were barriers to use besides cost and training; (3) if trackers would educate participants on their baseline and ongoing activity levels and support behavior change; and (4) if clinical outcomes would show improvements in participants' health. This study was conducted with patients (N=10) in a 12-week physician-led wellness group offered by Family Doctors, LLC. Patients were given trackers in the second week of The Wellness Group and were interviewed 2 to 4 weeks after it ended. The study investigators analyzed the interview notes to extract themes about the participants' attitudes and behavior changes and collected and analyzed participants' clinical data, including weight and low-density lipoprotein (LDL) cholesterol over the course of the study. Over the 12 to 14 weeks of tracker use, improvements were seen in clinical outcomes, attitudes towards the trackers, and physical activity behaviors. Participants lost an average of 0.5 lbs per week (SD 0.4), with a mean total weight loss of 5.97 lbs (P=.004). Other short-term clinical outcomes included a 9.2% decrease in LDL levels (P=.038). All participants reported an increase in well-being and confidence in their ability to lead more active lives. We identified the following 6 major attitudinal themes from our qualitative analysis of the interview notes: (1) barriers to tracker purchase included cost, perceived value, and choice confusion; (2) attitudes towards the trackers shifted for many, from half of the participants expressing excitement and hope and half expressing hesitation or trepidation, to all participants feeling positive towards their tracker at the time of the interviews; (3) trackers served as educational tools for baseline activity levels; (4) trackers provided concrete feedback on physical activity, which motivated behavior change; (5) tracker use reinforced wellness group activities and goals; and (6) although commitment to tracker use did not waver, external circumstances influenced some participants' ongoing use. Our findings suggest that adding trackers to wellness groups comprising primarily older adults with chronic medical conditions can support education and behavior change to be more physically active. The trackers increased participant self-efficacy by providing a tangible, visible reminder of a commitment to increasing activity and immediate feedback on step count and progress towards a daily step goal. While acceptance was high and attitudes ultimately positive, training and support are needed and short-term drop-off in participant use is to be expected. Future research will further consider the potential of trackers in older adults with chronic medical conditions who are unlikely to purchase them, and studies will use larger samples, continue over a longer period of time, and evaluate outcomes independent of a wellness group. ©Lisa Gualtieri, Sandra Rosenbluth, Jeffrey Phillips. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 30.11.2016.

  2. Sun-Relative Pointing for Dual-Axis Solar Trackers Employing Azimuth and Elevation Rotations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, Daniel; Hansen, Clifford W.

    Dual axis trackers employing azimuth and elevation rotations are common in the field of photovoltaic (PV) energy generation. Accurate sun-tracking algorithms are widely available. However, a steering algorithm has not been available to accurately point the tracker away from the sun such that a vector projection of the sun beam onto the tracker face falls along a desired path relative to the tracker face. We have developed an algorithm which produces the appropriate azimuth and elevation angles for a dual axis tracker when given the sun position, desired angle of incidence, and the desired projection of the sun beam ontomore » the tracker face. Development of this algorithm was inspired by the need to accurately steer a tracker to desired sun-relative positions in order to better characterize the electro-optical properties of PV and CPV modules.« less

  3. Moral Appraisals Affect Doing/Allowing Judgments

    ERIC Educational Resources Information Center

    Cushman, Fiery; Knobe, Joshua; Sinnott-Armstrong, Walter

    2008-01-01

    An extensive body of research suggests that the distinction between doing and allowing plays a critical role in shaping moral appraisals. Here, we report evidence from a pair of experiments suggesting that the converse is also true: moral appraisals affect doing/allowing judgments. Specifically, morally bad behavior is more likely to be construed…

  4. Effects of Visual and Verbal Interaction on Unintentional Interpersonal Coordination

    ERIC Educational Resources Information Center

    Richardson, Michael J.; Marsh, Kerry L.; Schmidt, R. C.

    2005-01-01

    Previous research has demonstrated that people's movements can become unintentionally coordinated during interpersonal interaction. The current study sought to uncover the degree to which visual and verbal (conversation) interaction constrains and organizes the rhythmic limb movements of coactors. Two experiments were conducted in which pairs of…

  5. Speed Pairs, a Spoken Exercise

    ERIC Educational Resources Information Center

    Kishi, Adrienne

    2017-01-01

    While written exercises may serve students adequately on tests, the structures they emphasize can remain elusive or difficult for students to master in conversation. Students tend to interpret their difficulty in applying what they have learned as a lack of language ability, and they can quickly lose confidence when speaking. Producing a target…

  6. Testing FlowTracker2 Performance and Wading Rod Flow Disturbance in Laboratory Tow Tanks

    NASA Astrophysics Data System (ADS)

    Fan, X.; Wagenaar, D.

    2016-12-01

    The FlowTracker2 was released in February 2016 by SonTek (Xylem) to be a more feature-rich and technologically advanced replacement to the Original FlowTracker ADV. These instruments are Acoustic Doppler Velocimeters (ADVs) used for taking high-precision wading discharge and velocity measurements. The accuracy of the FlowTracker2 probe was tested in tow tanks at three different facilities: the USGS Hydrologic Instrumentation Facility (HIF), the Swiss Federal Institute for Metrology (METAS), and at the SonTek Research and Development facility. Multiple mounting configurations were examined, including mounting the ADV probe directly to the tow carts, and incorporating the two most-used wading rods for the FlowTracker (round and hex). Tow speeds ranged from 5cm/s to 1.5m/s, and different tow tank seeding schemes and wait times were examined. In addition, the performance of the FlowTracker2 probe in low Signal-to-Noise Ratio (SNR) environments was compared to the Original FlowTracker ADV. Results confirmed that the FlowTracker2 probe itself performed well within the 1%+0.25cm/s accuracy specification advertised. Tows using the wading rods created a reduced measured velocity by 1.3% of the expected velocity due to flow disturbance, a result similar to the Original FlowTracker ADV despite the change in the FlowTracker2 probe design. Finally, due to improvements in its electronics, the FlowTracker2's performance in low SNR tests exceeded that of the Original FlowTracker ADV, showing less standard error in these conditions compared to its predecessor.

  7. Conversion of carbohydrate into hydrogen fuel by a photocatalytic process

    NASA Astrophysics Data System (ADS)

    Kawai, T.; Sakata, T.

    1980-07-01

    A photocatalytic process for the conversion of carbohydrates into hydrogen fuel is presented. The method involves the irradiation of sugar, starch or cellulose in the presence of water and a RuO2/TiO2/Pt catalyst, which has been found to lead to the generation of CO2 and H2 at efficiencies 100 times larger than those obtained with TiO2 alone, with no detectable amounts of other products. The reaction mechanism can be explained in terms of an electrochemical microcell, in which electron-hole pairs generated in TiO2 cause redox reactions at the surface. The process may thus be used in the conversion of solar energy stored in the form of carbohydrates by green plant photosynthesis into useful hydrogen fuels.

  8. Generation of Nonclassical Biphoton States through Cascaded Quantum Walks on a Nonlinear Chip

    NASA Astrophysics Data System (ADS)

    Solntsev, Alexander S.; Setzpfandt, Frank; Clark, Alex S.; Wu, Che Wen; Collins, Matthew J.; Xiong, Chunle; Schreiber, Andreas; Katzschmann, Fabian; Eilenberger, Falk; Schiek, Roland; Sohler, Wolfgang; Mitchell, Arnan; Silberhorn, Christine; Eggleton, Benjamin J.; Pertsch, Thomas; Sukhorukov, Andrey A.; Neshev, Dragomir N.; Kivshar, Yuri S.

    2014-07-01

    We demonstrate a nonlinear optical chip that generates photons with reconfigurable nonclassical spatial correlations. We employ a quadratic nonlinear waveguide array, where photon pairs are generated through spontaneous parametric down-conversion and simultaneously spread through quantum walks between the waveguides. Because of the quantum interference of these cascaded quantum walks, the emerging photons can become entangled over multiple waveguide positions. We experimentally observe highly nonclassical photon-pair correlations, confirming the high fidelity of on-chip quantum interference. Furthermore, we demonstrate biphoton-state tunability by spatial shaping and frequency tuning of the classical pump beam.

  9. Total teleportation of a single-photon state

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humble, Travis S; Bennink, Ryan S; Grice, Warren P

    2008-01-01

    Recent demonstrations of teleportation have transferred quantum information encoded into either polarization or field-quadrature degrees of freedom (DOFs), but an outstanding question is how to simultaneously teleport quantum information encoded into multiple DOFs. We describe how the transverse-spatial, spectral and polarization states of a single photon can be simultaneously teleported using a pair of multimode, polarization-entangled photons derived from spontaneous parametric down-conversion. Furthermore, when the initial photon pair is maximally entangled in the spatial, spectral, and polarization DOFs then the photon s full quantum state can be reliably teleported using a Bell-state measurement based on sum-frequency generation.

  10. Units of rotational information

    NASA Astrophysics Data System (ADS)

    Yang, Yuxiang; Chiribella, Giulio; Hu, Qinheping

    2017-12-01

    Entanglement in angular momentum degrees of freedom is a precious resource for quantum metrology and control. Here we study the conversions of this resource, focusing on Bell pairs of spin-J particles, where one particle is used to probe unknown rotations and the other particle is used as reference. When a large number of pairs are given, we show that every rotated spin-J Bell state can be reversibly converted into an equivalent number of rotated spin one-half Bell states, at a rate determined by the quantum Fisher information. This result provides the foundation for the definition of an elementary unit of information about rotations in space, which we call the Cartesian refbit. In the finite copy scenario, we design machines that approximately break down Bell states of higher spins into Cartesian refbits, as well as machines that approximately implement the inverse process. In addition, we establish a quantitative link between the conversion of Bell states and the simulation of unitary gates, showing that the fidelity of probabilistic state conversion provides upper and lower bounds on the fidelity of deterministic gate simulation. The result holds not only for rotation gates, but also to all sets of gates that form finite-dimensional representations of compact groups. For rotation gates, we show how rotations on a system of given spin can simulate rotations on a system of different spin.

  11. Weak e+e- lines from internal pair conversion observed in collisions of 238U with heavy nuclei

    NASA Astrophysics Data System (ADS)

    Heinz, S.; Berdermann, E.; Heine, F.; Joeres, O.; Kienle, P.; Koenig, I.; Koenig, W.; Kozhuharov, C.; Leinberger, U.; Rhein, M.; Schröter, A.; Tsertos, H.

    1998-01-01

    We present the results of a Doppler-shift correction to the measured e+e- sum-energy spectra obtained from e+e- coincidence measurements in 238U +206Pb and 238U +181Ta collisions at beam energies close to the Coulomb barrier, using an improved experimental setup at the double-Orange spectrometer of GSI. Internal-Pair-Conversion (IPC) e+e- pairs from discrete nuclear transitions of a moving emitter have been observed following Coulomb excitation of the 1.844 MeV (E1) transition in 206Pb and neutron transfer to the 1.770 MeV (M1) transition in 207Pb. In the collision system 238U +181Ta, IPC transitions were observed from the Ta-like as well as from the U-like nuclei. In all systems the Doppler-shift corrected e+e- sum-energy spectra show weak lines at the energies expected from the corresponding γ ray spectra with cross sections being consistent with the measured excitation cross sections of the γ lines and the theoretically predicted IPC coefficients. No other than IPC e+e- sum-energy lines were found in the measured spectra. The transfer cross sections show a strong dependence on the distance of closest approach (Rmin), thus signaling also a strong dependence on the bombarding energy close to the Coulomb barrier.

  12. Experimental Demonstration of a Hybrid-Quantum-Emitter Producing Individual Entangled Photon Pairs in the Telecom Band

    PubMed Central

    Chen, Geng; Zou, Yang; Zhang, Wen-Hao; Zhang, Zi-Huai; Zhou, Zong-Quan; He, De-Yong; Tang, Jian-Shun; Liu, Bi-Heng; Yu, Ying; Zha, Guo-Wei; Ni, Hai-Qiao; Niu, Zhi-Chuan; Han, Yong-Jian; Li, Chuan-Feng; Guo, Guang-Can

    2016-01-01

    Quantum emitters generating individual entangled photon pairs (IEPP) have significant fundamental advantages over schemes that suffer from multiple photon emission, or schemes that require post-selection techniques or the use of photon-number discriminating detectors. Quantum dots embedded within nanowires (QD-NWs) represent one of the most promising candidate for quantum emitters that provide a high collection efficiency of photons. However, a quantum emitter that generates IEPP in the telecom band is still an issue demanding a prompt solution. Here, we demonstrate in principle that IEPPs in the telecom band can be created by combining a single QD-NW and a nonlinear crystal waveguide. The QD-NW system serves as the single photon source, and the emitted visible single photons are split into IEPPs at approximately 1.55 μm through the process of spontaneous parametric down conversion (SPDC) in a periodically poled lithium niobate (PPLN) waveguide. The compatibility of the QD-PPLN interface is the determinant factor in constructing this novel hybrid-quantum-emitter (HQE). Benefiting from the desirable optical properties of QD-NWs and the extremely high nonlinear conversion efficiency of PPLN waveguides, we successfully generate IEPPs in the telecom band with the polarization degree of freedom. The entanglement of the generated photon pairs is confirmed by the entanglement witness. Our experiment paves the way to producing HQEs inheriting the advantages of multiple systems. PMID:27225881

  13. Experimental Demonstration of a Hybrid-Quantum-Emitter Producing Individual Entangled Photon Pairs in the Telecom Band.

    PubMed

    Chen, Geng; Zou, Yang; Zhang, Wen-Hao; Zhang, Zi-Huai; Zhou, Zong-Quan; He, De-Yong; Tang, Jian-Shun; Liu, Bi-Heng; Yu, Ying; Zha, Guo-Wei; Ni, Hai-Qiao; Niu, Zhi-Chuan; Han, Yong-Jian; Li, Chuan-Feng; Guo, Guang-Can

    2016-05-26

    Quantum emitters generating individual entangled photon pairs (IEPP) have significant fundamental advantages over schemes that suffer from multiple photon emission, or schemes that require post-selection techniques or the use of photon-number discriminating detectors. Quantum dots embedded within nanowires (QD-NWs) represent one of the most promising candidate for quantum emitters that provide a high collection efficiency of photons. However, a quantum emitter that generates IEPP in the telecom band is still an issue demanding a prompt solution. Here, we demonstrate in principle that IEPPs in the telecom band can be created by combining a single QD-NW and a nonlinear crystal waveguide. The QD-NW system serves as the single photon source, and the emitted visible single photons are split into IEPPs at approximately 1.55 μm through the process of spontaneous parametric down conversion (SPDC) in a periodically poled lithium niobate (PPLN) waveguide. The compatibility of the QD-PPLN interface is the determinant factor in constructing this novel hybrid-quantum-emitter (HQE). Benefiting from the desirable optical properties of QD-NWs and the extremely high nonlinear conversion efficiency of PPLN waveguides, we successfully generate IEPPs in the telecom band with the polarization degree of freedom. The entanglement of the generated photon pairs is confirmed by the entanglement witness. Our experiment paves the way to producing HQEs inheriting the advantages of multiple systems.

  14. Temporal plasticity in auditory cortex improves neural discrimination of speech sounds

    PubMed Central

    Engineer, Crystal T.; Shetake, Jai A.; Engineer, Navzer D.; Vrana, Will A.; Wolf, Jordan T.; Kilgard, Michael P.

    2017-01-01

    Background Many individuals with language learning impairments exhibit temporal processing deficits and degraded neural responses to speech sounds. Auditory training can improve both the neural and behavioral deficits, though significant deficits remain. Recent evidence suggests that vagus nerve stimulation (VNS) paired with rehabilitative therapies enhances both cortical plasticity and recovery of normal function. Objective/Hypothesis We predicted that pairing VNS with rapid tone trains would enhance the primary auditory cortex (A1) response to unpaired novel speech sounds. Methods VNS was paired with tone trains 300 times per day for 20 days in adult rats. Responses to isolated speech sounds, compressed speech sounds, word sequences, and compressed word sequences were recorded in A1 following the completion of VNS-tone train pairing. Results Pairing VNS with rapid tone trains resulted in stronger, faster, and more discriminable A1 responses to speech sounds presented at conversational rates. Conclusion This study extends previous findings by documenting that VNS paired with rapid tone trains altered the neural response to novel unpaired speech sounds. Future studies are necessary to determine whether pairing VNS with appropriate auditory stimuli could potentially be used to improve both neural responses to speech sounds and speech perception in individuals with receptive language disorders. PMID:28131520

  15. Multi-user distribution of polarization entangled photon pairs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trapateau, J.; Orieux, A.; Diamanti, E.

    We experimentally demonstrate multi-user distribution of polarization entanglement using commercial telecom wavelength division demultiplexers. The entangled photon pairs are generated from a broadband source based on spontaneous parametric down conversion in a periodically poled lithium niobate crystal using a double path setup employing a Michelson interferometer and active phase stabilisation. We test and compare demultiplexers based on various technologies and analyze the effect of their characteristics, such as losses and polarization dependence, on the quality of the distributed entanglement for three channel pairs of each demultiplexer. In all cases, we obtain a Bell inequality violation, whose value depends on themore » demultiplexer features. This demonstrates that entanglement can be distributed to at least three user pairs of a network from a single source. Additionally, we verify for the best demultiplexer that the violation is maintained when the pairs are distributed over a total channel attenuation corresponding to 20 km of optical fiber. These techniques are therefore suitable for resource-efficient practical implementations of entanglement-based quantum key distribution and other quantum communication network applications.« less

  16. Autonomous star tracker based on active pixel sensors (APS)

    NASA Astrophysics Data System (ADS)

    Schmidt, U.

    2017-11-01

    Star trackers are opto-electronic sensors used onboard of satellites for the autonomous inertial attitude determination. During the last years, star trackers became more and more important in the field of the attitude and orbit control system (AOCS) sensors. High performance star trackers are based up today on charge coupled device (CCD) optical camera heads. The Jena-Optronik GmbH is active in the field of opto-electronic sensors like star trackers since the early 80-ties. Today, with the product family ASTRO5, ASTRO10 and ASTRO15, all marked segments like earth observation, scientific applications and geo-telecom are supplied to European and Overseas customers. A new generation of star trackers can be designed based on the APS detector technical features. The measurement performance of the current CCD based star trackers can be maintained, the star tracker functionality, reliability and robustness can be increased while the unit costs are saved.

  17. Stream Tracker: Crowd sourcing and remote sensing to monitor stream flow intermittence

    NASA Astrophysics Data System (ADS)

    Puntenney, K.; Kampf, S. K.; Newman, G.; Lefsky, M. A.; Weber, R.; Gerlich, J.

    2017-12-01

    Streams that do not flow continuously in time and space support diverse aquatic life and can be critical contributors to downstream water supply. However, these intermittent streams are rarely monitored and poorly mapped. Stream Tracker is a community powered stream monitoring project that pairs citizen contributed observations of streamflow presence or absence with a network of streamflow sensors and remotely sensed data from satellites to track when and where water is flowing in intermittent stream channels. Citizens can visit sites on roads and trails to track flow and contribute their observations to the project site hosted by CitSci.org. Data can be entered using either a mobile application with offline capabilities or an online data entry portal. The sensor network provides a consistent record of streamflow and flow presence/absence across a range of elevations and drainage areas. Capacitance, resistance, and laser sensors have been deployed to determine the most reliable, low cost sensor that could be mass distributed to track streamflow intermittence over a larger number of sites. Streamflow presence or absence observations from the citizen and sensor networks are then compared to satellite imagery to improve flow detection algorithms using remotely sensed data from Landsat. In the first two months of this project, 1,287 observations have been made at 241 sites by 24 project members across northern and western Colorado.

  18. Imaging X-Ray Polarimetry Explorer Mission Attitude Determination and Control Concept

    NASA Technical Reports Server (NTRS)

    Bladt, Jeff; Deininger, William D.; Kalinowski, William C.; Boysen, Mary; Bygott, Kyle; Guy, Larry; Pentz, Christina; Seckar, Chris; Valdez, John; Wedmore, Jeffrey; hide

    2018-01-01

    The goal of the Imaging X-Ray Polarimetry Explorer (IXPE) Mission is to expand understanding of high-energy astrophysical processes and sources, in support of NASA's first science objective in Astrophysics: "Discover how the universe works." X-ray polarimetry is the focus of the IXPE science mission. Polarimetry uniquely probes physical anisotropies-ordered magnetic fields, aspheric matter distributions, or general relativistic coupling to black-hole spin-that are not otherwise measurable. The IXPE Observatory consists of Spacecraft and Payload modules. The Payload includes three polarization sensitive, X-ray detector units (DU), each paired with its corresponding grazing incidence mirror module assemblies (MMA). A deployable boom provides the correct separation (focal length) between the DUs and MMAs. These Payload elements are supported by the IXPE Spacecraft. A star tracker is mounted directly with the deployed Payload to minimize alignment errors between the star tracker line of sight (LoS) and Payload LoS. Stringent pointing requirements coupled with a flexible structure and a non-collocated attitude sensor-actuator configuration requires a thorough analysis of control-structure interactions. A non-minimum phase notch filter supports robust control loop stability margins. This paper summarizes the IXPE mission science objectives and Observatory concepts, and then it describes IXPE attitude determination and control implementation. IXPE LoS pointing accuracy, control loop stability, and angular momentum management are discussed.

  19. Interest and preferences for using advanced physical activity tracking devices: results of a national cross-sectional survey

    PubMed Central

    Alley, Stephanie; Schoeppe, Stephanie; Guertler, Diana; Jennings, Cally; Vandelanotte, Corneel

    2016-01-01

    Objectives Pedometers are an effective self-monitoring tool to increase users' physical activity. However, a range of advanced trackers that measure physical activity 24 hours per day have emerged (eg, Fitbit). The current study aims to determine people's current use, interest and preferences for advanced trackers. Design and participants A cross-sectional national telephone survey was conducted in Australia with 1349 respondents. Outcome measures Regression analyses were used to determine whether tracker interest and use, and use of advanced trackers over pedometers is a function of demographics. Preferences for tracker features and reasons for not wanting to wear a tracker are also presented. Results Over one-third of participants (35%) had used a tracker, and 16% are interested in using one. Multinomial regression (n=1257) revealed that the use of trackers was lower in males (OR=0.48, 95% CI 0.36 to 0.65), non-working participants (OR=0.43, 95% CI 0.30 to 0.61), participants with lower education (OR=0.52, 95% CI 0.38 to 0.72) and inactive participants (OR=0.52, 95% CI 0.39 to 0.70). Interest in using a tracker was higher in younger participants (OR=1.73, 95% CI 1.15 to 2.58). The most frequently used tracker was a pedometer (59%). Logistic regression (n=445) revealed that use of advanced trackers compared with pedometers was higher in males (OR=1.67, 95% CI 1.01 to 2.79) and younger participants (OR=2.96, 95% CI 1.71 to 5.13), and lower in inactive participants (OR=0.35, 95% CI 0.19 to 0.63). Over half of current or interested tracker users (53%) prefer to wear it on their wrist, 31% considered counting steps the most important function and 30% regarded accuracy as the most important characteristic. The main reasons for not wanting to use a tracker were, ‘I don't think it would help me’ (39%), and ‘I don't want to increase my activity’ (47%). Conclusions Activity trackers are a promising tool to engage people in self-monitoring a physical activity. Trackers used in physical activity interventions should align with the preferences of target groups, and should be able to be worn on the wrist, measure steps and be accurate. PMID:27388359

  20. Quantitative in vivo CT arthrography of the human osteoarthritic knee to estimate cartilage sulphated glycosaminoglycan content: correlation with ex-vivo reference standards.

    PubMed

    van Tiel, J; Siebelt, M; Reijman, M; Bos, P K; Waarsing, J H; Zuurmond, A-M; Nasserinejad, K; van Osch, G J V M; Verhaar, J A N; Krestin, G P; Weinans, H; Oei, E H G

    2016-06-01

    Recently, computed tomography arthrography (CTa) was introduced as quantitative imaging biomarker to estimate cartilage sulphated glycosaminoglycan (sGAG) content in human cadaveric knees. Our aim was to assess the correlation between in vivo CTa in human osteoarthritis (OA) knees and ex vivo reference standards for sGAG and collagen content. In this prospective observational study 11 knee OA patients underwent CTa before total knee replacement (TKR). Cartilage X-ray attenuation was determined in six cartilage regions. Femoral and tibial cartilage specimens harvested during TKR were re-scanned using equilibrium partitioning of an ionic contrast agent with micro-CT (EPIC-μCT), which served as reference standard for sGAG. Next, cartilage sGAG and collagen content were determined using dimethylmethylene blue (DMMB) and hydroxyproline assays. The correlation between CTa X-ray attenuation, EPIC-μCT X-ray attenuation, sGAG content and collagen content was assessed. CTa X-ray attenuation correlated well with EPIC-μCT (r = 0.76, 95% credibility interval (95%CI) 0.64 to 0.85). CTa correlated moderately with the DMMB assay (sGAG content) (r = -0.66, 95%CI -0.87 to -0.49) and to lesser extent with the hydroxyproline assay (collagen content) (r = -0.56, 95%CI -0.70 to -0.36). Outcomes of in vivo CTa in human OA knees correlate well with sGAG content. Outcomes of CTa also slightly correlate with cartilage collagen content. Since outcomes of CTa are mainly sGAG dependent and despite the fact that further validation using hyaline cartilage of other joints with different biochemical composition should be conducted, CTa may be suitable as quantitative imaging biomarker to estimate cartilage sGAG content in future clinical OA research. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  1. Structural Associations of Symptomatic Knee Osteoarthritis

    PubMed Central

    Stoppiello, Laura A; Mapp, Paul I; Wilson, Deborah; Hill, Roger; Scammell, Brigitte E; Walsh, David A

    2014-01-01

    Objective Structural changes of osteoarthritis (OA) may occur in the absence of pain. In this study, we aimed to identify histopathologic features that are associated with symptomatic knee OA. Methods Medial tibial plateaus and synovium samples were obtained at the time of total knee replacement (TKR) surgery for OA (advanced OA group) or were obtained postmortem from subjects who had not sought medical attention for knee pain during the last year of life (non-OA control group). To identify features of OA, we compared the patients with advanced OA with the age-matched non-OA controls (n = 26 per group). To identify OA features associated with symptoms, we compared two additional groups of subjects who were matched for severity of chondropathy (n = 29 per group): patients undergoing TKR for symptomatic OA (symptomatic chondropathy group) and postmortem subjects with similar severity of chondropathy who were asymptomatic during the last year of life (asymptomatic chondropathy group). The histologic features of the samples were graded, and immunoreactivities for macrophages (CD68) and nerve growth factor (NGF) in the synovium were quantified. The cellular localization of synovial NGF was determined by double immunofluorescence analysis. Results Advanced OA cases displayed more severe changes in the synovium (synovitis, increased synovial NGF, and CD68-immunoreactive macrophages) and cartilage (loss of cartilage surface integrity, loss of proteoglycan, tidemark breaching, and alterations in chondrocyte morphology) than did the non-OA controls. Synovial NGF was localized predominantly to fibroblasts and to some macrophages. The symptomatic chondropathy group displayed greater levels of synovitis, synovial NGF, and loss of cartilage integrity, in addition to alterations in chondrocyte morphology, than did the asymptomatic chondropathy group (P < 0.05 for each comparison). Conclusion Synovitis, increased synovial NGF, alterations in chondrocyte morphology, and loss of cartilage integrity are features of knee OA that may be associated with symptoms. PMID:25049144

  2. Which total knee replacement implant should I pick? Correcting the pathology: the role of knee bearing designs.

    PubMed

    Berend, K R; Lombardi, A V; Adams, J B

    2013-11-01

    Debate has raged over whether a cruciate retaining (CR) or a posterior stabilised (PS) total knee replacement (TKR) provides a better range of movement (ROM) for patients. Various sub-sets of CR design are frequently lumped together when comparing outcomes. Additionally, multiple factors have been proven to influence the rate of manipulation under anaesthetic (MUA) following TKR. The purpose of this study was to determine whether different CR bearing insert designs provide better ROM or different MUA rates. All primary TKRs performed by two surgeons between March 2006 and March 2009 were reviewed and 2449 CR-TKRs were identified. The same CR femoral component, instrumentation, and tibial base plate were consistently used. In 1334 TKRs a CR tibial insert with 3° posterior slope and no posterior lip was used (CR-S). In 803 there was an insert with no slope and a small posterior lip (CR-L) and in 312 knees the posterior cruciate ligament (PCL) was either resected or lax and a deep-dish, anterior stabilised insert was used (CR-AS). More CR-AS inserts were used in patients with less pre-operative ROM and greater pre-operative tibiofemoral deformity and flexion contracture (p < 0.05). The mean improvement in ROM was highest for the CR-AS inserts (5.9° (-40° to 55°) vs CR-S 3.1° (-45° to 70°) vs CR-L 3.0° (-45° to 65°); p = 0.004). There was a significantly higher MUA rate with the CR-S and CR-L inserts than CR-AS (Pearson rank 6.51; p = 0.04). Despite sacrificing or not substituting for the PCL, ROM improvement was highest, and the MUA rate was lowest in TKRs with a deep-dish, anterior-stabilised insert. Substitution for the posterior cruciate ligament (PCL) in the form of a PS design may not be necessary even when the PCL is deficient.

  3. MID-VASTUS VS MEDIAL PARA-PATELLAR APPROACH IN TOTAL KNEE REPLACEMENT—TIME TO DISCHARGE

    PubMed Central

    Mukherjee, P.; Press, J.; Hockings, M.

    2009-01-01

    Background It has been shown before that when compared with the medial para-patellar approach, the mid-vastus approach for TKR results in less post-operative pain for patients and more rapid recovery of straight leg raise. As far as we are aware the post-operative length of stay of the two groups of patients has not been compared. We postulated that the reduced pain and more rapid recovery of straight leg raise would translate into an earlier, safe, discharge home for the mid-vastus patients compared with those who underwent a traditional medial para-patellar approach. Methods Twenty patients operated on by each of five established knee arthroplasty surgeons were evaluated prospectively with regard to their pre and post-operative range of movement, time to achieve straight leg raise post-operatively and length of post-operative hospital stay. Only one of the surgeons performed the mid-vastus approach, and the measurements were recorded by physiotherapists who were blinded as to the approach used on each patient. Results The results were analysed using a standard statistical software package, and although the mean length of stay was lower for the mid-vastus patients, the difference did not reach a level of significance (p = 0.13). The time taken to achieve straight leg raise post-operatively was significantly less in the mid-vastus group (p<0.001). Conclusion Although this study confirms previous findings that the mid-vastus approach reduces the time taken for patients to achieve straight leg raise, when compared with the medial para-patellar approach, on its own it does not translate into a significantly shorter length of hospital stay. In order to reduce the length of post-operative hospital stay with an accelerated rehabilitation program for TKR, a multi-disciplinary approach is required. Patient expectations, GP support, physiotherapists and nursing staff all have a role to play and the mid-vastus approach, in permitting earlier straight leg raising, significantly contributes to this. PMID:19742080

  4. Current Risk Adjustment and Comorbidity Index Underperformance in Predicting Post-Acute Utilization and Hospital Readmissions After Joint Replacements: Implications for Comprehensive Care for Joint Replacement Model.

    PubMed

    Kumar, Amit; Karmarkar, Amol; Downer, Brian; Vashist, Amit; Adhikari, Deepak; Al Snih, Soham; Ottenbacher, Kenneth

    2017-11-01

    To compare the performances of 3 comorbidity indices, the Charlson Comorbidity Index, the Elixhauser Comorbidity Index, and the Centers for Medicare & Medicaid Services (CMS) risk adjustment model, Hierarchical Condition Category (HCC), in predicting post-acute discharge settings and hospital readmission for patients after joint replacement. A retrospective study of Medicare beneficiaries with total knee replacement (TKR) or total hip replacement (THR) discharged from hospitals in 2009-2011 (n = 607,349) was performed. Study outcomes were post-acute discharge setting and unplanned 30-, 60-, and 90-day hospital readmissions. Logistic regression models were built to compare the performance of the 3 comorbidity indices using C statistics. The base model included patient demographics and hospital use. Subsequent models included 1 of the 3 comorbidity indices. Additional multivariable logistic regression models were built to identify individual comorbid conditions associated with high risk of hospital readmissions. The 30-, 60-, and 90-day unplanned hospital readmission rates were 5.3%, 7.2%, and 8.5%, respectively. Patients were most frequently discharged to home health (46.3%), followed by skilled nursing facility (40.9%) and inpatient rehabilitation facility (12.7%). The C statistics for the base model in predicting post-acute discharge setting and 30-, 60-, and 90-day readmission in TKR and THR were between 0.63 and 0.67. Adding the Charlson Comorbidity Index, the Elixhauser Comorbidity Index, or HCC increased the C statistic minimally from the base model for predicting both discharge settings and hospital readmission. The health conditions most frequently associated with hospital readmission were diabetes mellitus, pulmonary disease, arrhythmias, and heart disease. The comorbidity indices and CMS-HCC demonstrated weak discriminatory ability to predict post-acute discharge settings and hospital readmission following joint replacement. © 2017, American College of Rheumatology.

  5. Cost feasibility of a pre-checking medical tourism system for U.S. patients undertaking joint replacement surgery in Taiwan.

    PubMed

    Haung, Ching-Ying; Wang, Sheng-Pen; Chiang, Chih-Wei

    2010-01-01

    Medical tourism is a relatively recent global economic and political phenomenon that has assumed increasing importance for developing countries, particularly in Asia. In fact, Taiwan possesses a niche for developing medical tourism because many hospitals provide state-of-the-art medicine in all disciplines and many doctors are trained in the United States (US). Among the most common medical procedures outsourced, joint replacements such as total knee replacement (TKR) and total hip replacement (THR) are two surgeries offered to US patients at a lower cost and shorter waiting time than in the US. This paper proposed a pre-checking medical tourism system (PCMTS) and evaluated the cost feasibility of recruiting American clients traveling to Taiwan for joint replacement surgery. Cost analysis was used to estimate the prime costs for each stage in the proposed PCMTS. Sensitivity analysis was implemented to examine how different pricings for medical checking and a surgical operation (MC&SO) and recovery, can influence the surplus per patient considering the PCMTS. Finally, the break-even method was adopted to test the tradeoff between the sunk costs of investment in the PCMTS and the annual surplus for participating hospitals. A novel business plan was built showing that pre-checking stations in medical tourism can provide post-operative care and recovery follow-up. Adjustable pricing for hospital administrators engaged in the PCMTS consisted of two main costs: US$3,700 for MC&SO and US$120 for the hospital stay. Guidelines for pricing were provided to maximize the annual surplus from this plan with different number of patients participating in PCMTS. The maximal profit margin from each American patient undertaking joint surgery is about US$24,315. Using cost analysis, this article might be the first to evaluate the feasibility of PCMTS for joint replacement surgeries. The research framework in this article is applicable when hospital administrators evaluate the feasibility of outsourced medical procedures other than TKR and THR.

  6. Model-based evaluation of cost-effectiveness of nerve growth factor inhibitors in knee osteoarthritis: impact of drug cost, toxicity, and means of administration.

    PubMed

    Losina, E; Michl, G; Collins, J E; Hunter, D J; Jordan, J M; Yelin, E; Paltiel, A D; Katz, J N

    2016-05-01

    Studies suggest nerve growth factor inhibitors (NGFi) relieve pain but may accelerate disease progression in some patients with osteoarthritis (OA). We sought cost and toxicity thresholds that would make NGFi a cost-effective treatment for moderate-to-severe knee OA. We used the Osteoarthritis Policy (OAPol) model to estimate the cost-effectiveness of NGFi compared to standard of care (SOC) in OA, using Tanezumab as an example. Efficacy and rates of accelerated OA progression were based on published studies. We varied the price/dose from $200 to $1000. We considered self-administered subcutaneous (SC) injections (no administration cost) vs provider-administered intravenous (IV) infusion ($69-$433/dose). Strategies were defined as cost-effective if their incremental cost-effectiveness ratio (ICER) was less than $100,000/quality-adjusted life year (QALY). In sensitivity analyses we varied efficacy, toxicity, and costs. SOC in patients with high levels of pain led to an average discounted quality-adjusted life expectancy of 11.15 QALYs, a lifetime risk of total knee replacement surgery (TKR) of 74%, and cumulative discounted direct medical costs of $148,700. Adding Tanezumab increased QALYs to 11.42, reduced primary TKR utilization to 63%, and increased costs to between $155,400 and $199,500. In the base-case analysis, Tanezumab at $600/dose was cost-effective when delivered outside of a hospital. At $1000/dose, Tanezumab was not cost-effective in all but the most optimistic scenario. Only at rates of accelerated OA progression of 10% or more (10-fold higher than reported values) did Tanezumab decrease QALYs and fail to represent a viable option. At $100,000/QALY, Tanezumab would be cost effective if priced ≤$400/dose in all settings except IV hospital delivery. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  7. Reliability of medical record abstraction by non-physicians for orthopedic research.

    PubMed

    Mi, Michael Y; Collins, Jamie E; Lerner, Vladislav; Losina, Elena; Katz, Jeffrey N

    2013-06-09

    Medical record review (MRR) is one of the most commonly used research methods in clinical studies because it provides rich clinical detail. However, because MRR involves subjective interpretation of information found in the medical record, it is critically important to understand the reproducibility of data obtained from MRR. Furthermore, because medical record review is both technically demanding and time intensive, it is important to establish whether trained research staff with no clinical training can abstract medical records reliably. We assessed the reliability of abstraction of medical record information in a sample of patients who underwent total knee replacement (TKR) at a referral center. An orthopedic surgeon instructed two research coordinators (RCs) in the abstraction of inpatient medical records and operative notes for patients undergoing primary TKR. The two RCs and the surgeon each independently reviewed 75 patients' records and one RC reviewed the records twice. Agreement was assessed using the proportion of items on which reviewers agreed and the kappa statistic. The kappa for agreement between the surgeon and each RC ranged from 0.59 to 1 for one RC and 0.49 to 1 for the other; the percent agreement ranged from 82% to 100% for one RC and 70% to 100% for the other. The repeated abstractions by the same RC showed high intra-rater agreement, with kappas ranging from 0.66 to 1 and percent agreement ranging from 97% to 100%. Inter-rater agreement between the two RCs was moderate with kappa ranging from 0.49 to 1 and percent agreement ranging from 76% to 100%. The MRR method used in this study showed excellent reliability for abstraction of information that had low technical complexity and moderate to good reliability for information that had greater complexity. Overall, these findings support the use of non-surgeons to abstract surgical data from operative notes.

  8. Systematic review of the concurrent and predictive validity of MRI biomarkers in OA

    PubMed Central

    Hunter, D.J.; Zhang, W.; Conaghan, Philip G.; Hirko, K.; Menashe, L.; Li, L.; Reichmann, W.M.; Losina, E.

    2012-01-01

    SUMMARY Objective To summarize literature on the concurrent and predictive validity of MRI-based measures of osteoarthritis (OA) structural change. Methods An online literature search was conducted of the OVID, EMBASE, CINAHL, PsychInfo and Cochrane databases of articles published up to the time of the search, April 2009. 1338 abstracts obtained with this search were preliminarily screened for relevance by two reviewers. Of these, 243 were selected for data extraction for this analysis on validity as well as separate reviews on discriminate validity and diagnostic performance. Of these 142 manuscripts included data pertinent to concurrent validity and 61 manuscripts for the predictive validity review. For this analysis we extracted data on criterion (concurrent and predictive) validity from both longitudinal and cross-sectional studies for all synovial joint tissues as it relates to MRI measurement in OA. Results Concurrent validity of MRI in OA has been examined compared to symptoms, radiography, histology/pathology, arthroscopy, CT, and alignment. The relation of bone marrow lesions, synovitis and effusion to pain was moderate to strong. There was a weak or no relation of cartilage morphology or meniscal tears to pain. The relation of cartilage morphology to radiographic OA and radiographic joint space was inconsistent. There was a higher frequency of meniscal tears, synovitis and other features in persons with radiographic OA. The relation of cartilage to other constructs including histology and arthroscopy was stronger. Predictive validity of MRI in OA has been examined for ability to predict total knee replacement (TKR), change in symptoms, radiographic progression as well as MRI progression. Quantitative cartilage volume change and presence of cartilage defects or bone marrow lesions are potential predictors of TKR. Conclusion MRI has inherent strengths and unique advantages in its ability to visualize multiple individual tissue pathologies relating to pain and also predict clinical outcome. The complex disease of OA which involves an array of tissue abnormalities is best imaged using this imaging tool. PMID:21396463

  9. Precision Pointing Control System (PPCS) star tracker test

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Tests performed on the TRW precision star tracker are described. The unit tested was a two-axis gimballed star tracker designed to provide star LOS data to an accuracy of 1 to 2 sec. The tracker features a unique bearing system and utilizes thermal and mechanical symmetry techniques to achieve high precision which can be demonstrated in a one g environment. The test program included a laboratory evaluation of tracker functional operation, sensitivity, repeatibility, and thermal stability.

  10. How does conversion of natural tropical rainforest ecosystems affect soil bacterial and fungal communities in the Nile river watershed of Uganda?

    PubMed

    Alele, Peter O; Sheil, Douglas; Surget-Groba, Yann; Lingling, Shi; Cannon, Charles H

    2014-01-01

    Uganda's forests are globally important for their conservation values but are under pressure from increasing human population and consumption. In this study, we examine how conversion of natural forest affects soil bacterial and fungal communities. Comparisons in paired natural forest and human-converted sites among four locations indicated that natural forest soils consistently had higher pH, organic carbon, nitrogen, and calcium, although variation among sites was large. Despite these differences, no effect on the diversity of dominant taxa for either bacterial or fungal communities was detected, using polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE). Composition of fungal communities did generally appear different in converted sites, but surprisingly, we did not observe a consistent pattern among sites. The spatial distribution of some taxa and community composition was associated with soil pH, organic carbon, phosphorus and sodium, suggesting that changes in soil communities were nuanced and require more robust metagenomic methods to understand the various components of the community. Given the close geographic proximity of the paired sampling sites, the similarity between natural and converted sites might be due to continued dispersal between treatments. Fungal communities showed greater environmental differentiation than bacterial communities, particularly according to soil pH. We detected biotic homogenization in converted ecosystems and substantial contribution of β-diversity to total diversity, indicating considerable geographic structure in soil biota in these forest communities. Overall, our results suggest that soil microbial communities are relatively resilient to forest conversion and despite a substantial and consistent change in the soil environment, the effects of conversion differed widely among sites. The substantial difference in soil chemistry, with generally lower nutrient quantity in converted sites, does bring into question, how long this resilience will last.

  11. Enlightenment of Yeast Mitochondrial Homoplasmy: Diversified Roles of Gene Conversion

    PubMed Central

    Ling, Feng; Mikawa, Tsutomu; Shibata, Takehiko

    2011-01-01

    Mitochondria have their own genomic DNA. Unlike the nuclear genome, each cell contains hundreds to thousands of copies of mitochondrial DNA (mtDNA). The copies of mtDNA tend to have heterogeneous sequences, due to the high frequency of mutagenesis, but are quickly homogenized within a cell (“homoplasmy”) during vegetative cell growth or through a few sexual generations. Heteroplasmy is strongly associated with mitochondrial diseases, diabetes and aging. Recent studies revealed that the yeast cell has the machinery to homogenize mtDNA, using a common DNA processing pathway with gene conversion; i.e., both genetic events are initiated by a double-stranded break, which is processed into 3′ single-stranded tails. One of the tails is base-paired with the complementary sequence of the recipient double-stranded DNA to form a D-loop (homologous pairing), in which repair DNA synthesis is initiated to restore the sequence lost by the breakage. Gene conversion generates sequence diversity, depending on the divergence between the donor and recipient sequences, especially when it occurs among a number of copies of a DNA sequence family with some sequence variations, such as in immunoglobulin diversification in chicken. MtDNA can be regarded as a sequence family, in which the members tend to be diversified by a high frequency of spontaneous mutagenesis. Thus, it would be interesting to determine why and how double-stranded breakage and D-loop formation induce sequence homogenization in mitochondria and sequence diversification in nuclear DNA. We will review the mechanisms and roles of mtDNA homoplasmy, in contrast to nuclear gene conversion, which diversifies gene and genome sequences, to provide clues toward understanding how the common DNA processing pathway results in such divergent outcomes. PMID:24710143

  12. How Does Conversion of Natural Tropical Rainforest Ecosystems Affect Soil Bacterial and Fungal Communities in the Nile River Watershed of Uganda?

    PubMed Central

    Alele, Peter O.; Sheil, Douglas; Surget-Groba, Yann; Lingling, Shi; Cannon, Charles H.

    2014-01-01

    Uganda's forests are globally important for their conservation values but are under pressure from increasing human population and consumption. In this study, we examine how conversion of natural forest affects soil bacterial and fungal communities. Comparisons in paired natural forest and human-converted sites among four locations indicated that natural forest soils consistently had higher pH, organic carbon, nitrogen, and calcium, although variation among sites was large. Despite these differences, no effect on the diversity of dominant taxa for either bacterial or fungal communities was detected, using polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE). Composition of fungal communities did generally appear different in converted sites, but surprisingly, we did not observe a consistent pattern among sites. The spatial distribution of some taxa and community composition was associated with soil pH, organic carbon, phosphorus and sodium, suggesting that changes in soil communities were nuanced and require more robust metagenomic methods to understand the various components of the community. Given the close geographic proximity of the paired sampling sites, the similarity between natural and converted sites might be due to continued dispersal between treatments. Fungal communities showed greater environmental differentiation than bacterial communities, particularly according to soil pH. We detected biotic homogenization in converted ecosystems and substantial contribution of β-diversity to total diversity, indicating considerable geographic structure in soil biota in these forest communities. Overall, our results suggest that soil microbial communities are relatively resilient to forest conversion and despite a substantial and consistent change in the soil environment, the effects of conversion differed widely among sites. The substantial difference in soil chemistry, with generally lower nutrient quantity in converted sites, does bring into question, how long this resilience will last. PMID:25118069

  13. Small star trackers for modern space vehicles

    NASA Astrophysics Data System (ADS)

    Kouzmin, Vladimir; Jushkov, Vladimir; Zaikin, Vladimir

    2017-11-01

    Based on experience of many years creation of spacecrafts' star trackers with diversified detectors (from the first star trackers of 60's to tens versions of star trackers in the following years), using technological achievements in the field of optics and electronics the NPP "Geofizika-Cosmos" has provided celestial orientation for all the space vehicles created in Russia and now has developed a series of new star trackers with CCD matrix and special processors, which are able to meet needs in celestial orientation of the modern spacecrafts for the nearest 10-15 years. In the given article the main characteristics and description of some star trackers' versions are presented. The star trackers have various levels of technical characteristics and use both combined (Russian and foreign) procurement parts, and only national (Russian) procurement parts for the main units.

  14. Plasma Heating and Alfvénic Turbulence Enhancement During Two Steps of Energy Conversion in Magnetic Reconnection Exhaust Region of Solar Wind

    NASA Astrophysics Data System (ADS)

    Jiansen, He; Xingyu, Zhu; Yajie, Chen; Chadi, Salem; Michael, Stevens; Hui, Li; Wenzhi, Ruan; Lei, Zhang; Chuanyi, Tu

    2018-04-01

    The magnetic reconnection exhaust is a pivotal region with enormous magnetic energy being continuously released and converted. The physical processes of energy conversion involved are so complicated that an all-round understanding based on in situ measurements is still lacking. We present the evidence of plasma heating by illustrating the broadening of proton and electron velocity distributions, which are extended mainly along the magnetic field, in an exhaust of interchange reconnection between two interplanetary magnetic flux tubes of the same polarity on the Sun. The exhaust is asymmetric across an interface, with both sides being bounded by a pair of compound discontinuities consisting of rotational discontinuity and slow shock. The energized plasmas are found to be firehose unstable, and responsible for the emanation of Alfvén waves during the second step of energy conversion. It is realized that the energy conversion in the exhaust can be a two-step process involving both plasma energization and wave emission.

  15. First Footing Inter-Faith Dialogue

    ERIC Educational Resources Information Center

    Luby, Antony

    2014-01-01

    This article examines an action research project on inter-faith dialogue within the sensitive context of Catholic pupils being taught Catholic religious education in state-funded secondary schools. Twenty pupils in S3 and S4 (Year 10 and Year 11) participated in a series of three paired conversations that focused primarily on science and religion,…

  16. Cooperative Autonomy in Online Lingua Franca Exchanges: A Case Study on Foreign Language Education in Secondary Schools

    ERIC Educational Resources Information Center

    Hoffstaedter, Petra; Kohn, Kurt

    2016-01-01

    We report on a case study on pedagogical affordances of intercultural telecollaboration for authentic communication practice and competence development in the local foreign language. Focus is on spoken and written conversations involving pairs of secondary school pupils of different linguacultural backgrounds. Particular attention is given to…

  17. SiC/Si diode trigger circuit provides automatic range switching for log amplifier

    NASA Technical Reports Server (NTRS)

    1967-01-01

    SiC/Si diode pair provides automatic range change to extend the operating range of a logarithmic amplifier-conversion circuit and assures stability at or near the range switch-over point. the diode provides hysteresis for a trigger circuit that actuates a relay at the desired range extension point.

  18. Here's Looking at You, Kid.

    ERIC Educational Resources Information Center

    Milshtein, Amy

    1997-01-01

    The University of Maryland at College Park installed 25 surveillance cameras to combat crime. A minimum of disruption occurred because unused twisted pair wires left in place when the conversion to a fiber optic telephone system was made could be used for the camera installations. The campus is safer, and its budget is intact. (RE)

  19. Whose Thinking Is It Anyway? Role-Pair Blends in the ALM Community.

    ERIC Educational Resources Information Center

    Duffin, Janet; Simpson, Adrian

    Evidence of tension between teachers and researchers regarding the work that researchers undertake in classrooms surfaces from time to time. The title of this conference, "A Conversation between Researchers and Practitioners", testifies to the importance of interaction between the users and providers of research. Indeed, in this paper, we will…

  20. Structural correlations in the generation of polaron pairs in low-bandgap polymers for photovoltaics

    NASA Astrophysics Data System (ADS)

    Tautz, Raphael; da Como, Enrico; Limmer, Thomas; Feldmann, Jochen; Egelhaaf, Hans-Joachim; von Hauff, Elizabeth; Lemaur, Vincent; Beljonne, David; Yilmaz, Seyfullah; Dumsch, Ines; Allard, Sybille; Scherf, Ullrich

    2012-07-01

    Polymeric semiconductors are materials where unique optical and electronic properties often originate from a tailored chemical structure. This allows for synthesizing conjugated macromolecules with ad hoc functionalities for organic electronics. In photovoltaics, donor-acceptor co-polymers, with moieties of different electron affinity alternating on the chain, have attracted considerable interest. The low bandgap offers optimal light-harvesting characteristics and has inspired work towards record power conversion efficiencies. Here we show for the first time how the chemical structure of donor and acceptor moieties controls the photogeneration of polaron pairs. We show that co-polymers with strong acceptors show large yields of polaron pair formation up to 24% of the initial photoexcitations as compared with a homopolymer (η=8%). π-conjugated spacers, separating the donor and acceptor centre of masses, have the beneficial role of increasing the recombination time. The results provide useful input into the understanding of polaron pair photogeneration in low-bandgap co-polymers for photovoltaics.

  1. An experimental investigation of preorgasmic reconditioning and postorgasmic deconditioning.

    PubMed Central

    Kantorowitz, D A

    1978-01-01

    The effects of pre- and postorgasmic presentation of moderately erotic cues were assessed in an analogue study. Eight heterosexual male volunteers (18 to 23 years) participated in three assessment (baseline, termination-of-treatment, and two- to three-month followup) and eight masturbatory conditioning sessions. Three slides of nude females of initially equal erotic value were paired respectively with the plateau, refractory, and resolution phases of the subjects' sexual cycles. Over treatment, stimuli paired with the plateau phase increased significantly in penile tumescence indices of eroticism; conversely, stimuli paired with the refractory phase decreased significantly. The conditioned effects on tumescence were largely extinguished at followup. While treatment did not alter short-term subjective indices of eroticism, stimuli presented during the refractory phase were rated significantly less erotic than the other stimuli at followup. The findings suggest that the "pairing" model of orgasmic conditioning is insufficient to account for previously reported clinical findings. A broader conceptualization of the mechanisms of orgasmic conditioning, and implications for treatment are discussed. PMID:649527

  2. An experimental investigation of preorgasmic reconditioning and postorgasmic deconditioning.

    PubMed

    Kantorowitz, D A

    1978-01-01

    The effects of pre- and postorgasmic presentation of moderately erotic cues were assessed in an analogue study. Eight heterosexual male volunteers (18 to 23 years) participated in three assessment (baseline, termination-of-treatment, and two- to three-month followup) and eight masturbatory conditioning sessions. Three slides of nude females of initially equal erotic value were paired respectively with the plateau, refractory, and resolution phases of the subjects' sexual cycles. Over treatment, stimuli paired with the plateau phase increased significantly in penile tumescence indices of eroticism; conversely, stimuli paired with the refractory phase decreased significantly. The conditioned effects on tumescence were largely extinguished at followup. While treatment did not alter short-term subjective indices of eroticism, stimuli presented during the refractory phase were rated significantly less erotic than the other stimuli at followup. The findings suggest that the "pairing" model of orgasmic conditioning is insufficient to account for previously reported clinical findings. A broader conceptualization of the mechanisms of orgasmic conditioning, and implications for treatment are discussed.

  3. Cryotherapy following total knee replacement.

    PubMed

    Adie, Sam; Kwan, Amy; Naylor, Justine M; Harris, Ian A; Mittal, Rajat

    2012-09-12

    Total knee replacement (TKR) is a common intervention for patients with end-stage osteoarthritis of the knee. Post-surgical management may include cryotherapy. However, the effectiveness of cryotherapy is unclear. To evaluate the acute (within 48 hours) application of cryotherapy following TKR on pain, blood loss and function. We searched the Cochrane Database of Systematic Reviews, CENTRAL, DARE, HTA Database, MEDLINE, EMBASE, CINAHL, PEDro and Web of Science on 15th March 2012. Randomised controlled trials or controlled clinical trials in which the experimental group received any form of cryotherapy, and was compared to any control group following TKR indicated for osteoarthritis. Two reviewers independently selected trials for inclusion. Disagreements were discussed and resolved involving a third reviewer if required. Data were then extracted and the risk of bias of trials assessed. Main outcomes were blood loss, visual analogue score (VAS) pain, adverse events, knee range of motion, transfusion rate and knee function. Secondary outcomes were analgesia use, knee swelling, length of hospital stay, quality of life and activity level. Effects of interventions were estimated as mean differences (MD), standardised mean differences (SMD) or given as risk ratios (RR), with 95% confidence intervals (CI). Meta-analyses were performed using the inverse variance method and pooled using random effects. Eleven randomised trials and one controlled clinical trial involving 809 participants met the inclusion criteria. There is very low quality evidence from 10 trials (666 participants) that cryotherapy has a small benefit on blood loss (SMD -0.46, 95% CI, -0.84 to -0.08), equivalent to 225mL less blood loss in cryotherapy group (95% CI, 39 to 410mL). This benefit may not be clinically significant. There was very low quality evidence from four trials (322 participants) that cryotherapy improved visual analogue score pain at 48 hours (MD = -1.32 points on a 10 point scale, 95% CI, -2.37 to -0.27), but not at 24 or 72 hours. This benefit may not be clinically significant. There was no difference between groups in adverse events (RR = 0.98, 95% CI, 0.28 to 3.47). There is low quality evidence from two trials (107 participants) for improved range of motion at discharge (MD 11.39 degrees of additional flexion, 95% CI 4.13 to 18.66), but this benefit may not be clinically significant. There was no difference between groups in transfusion rate (RR 2.13, 95% CI 0.04 to 109.63), and knee function was not measured in any trial. No significant benefit were found for analgesia use, swelling or length of stay. Outcomes measuring quality of life or activity level were not reported. Potential benefits of cryotherapy on blood loss, postoperative pain, and range of motion may be too small to justify its use, and the quality of the evidence was very low or low for all main outcomes. This needs to be balanced against potential inconveniences and expenses of using cryotherapy. Well designed randomised trials are required to improve the quality of the evidence.

  4. Energy conversion modeling of the intrinsic persistent luminescence of solids via energy transfer paths between transition levels.

    PubMed

    Huang, Bolong; Sun, Mingzi

    2017-04-05

    An energy conversion model has been established for the intrinsic persistent luminescence in solids related to the native point defect levels, formations, and transitions. In this study, we showed how the recombination of charge carriers between different defect levels along the zero phonon line (ZPL) can lead to energy conversions supporting the intrinsic persistent phosphorescence in solids. This suggests that the key driving force for this optical phenomenon is the pair of electrons hopping between different charged defects with negative-U eff . Such a negative correlation energy will provide a sustainable energy source for electron-holes to further recombine in a new cycle with a specific quantum yield. This will help us to understand the intrinsic persistent luminescence with respect to native point defect levels as well as the correlations of electronics and energetics.

  5. Properties of entangled photon pairs generated in one-dimensional nonlinear photonic-band-gap structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perina, Jan Jr.; Centini, Marco; Sibilia, Concita

    We have developed a rigorous quantum model of spontaneous parametric down-conversion in a nonlinear 1D photonic-band-gap structure based upon expansion of the field into monochromatic plane waves. The model provides a two-photon amplitude of a created photon pair. The spectra of the signal and idler fields, their intensity profiles in the time domain, as well as the coincidence-count interference pattern in a Hong-Ou-Mandel interferometer are determined both for cw and pulsed pumping regimes in terms of the two-photon amplitude. A broad range of parameters characterizing the emitted down-converted fields can be used. As an example, a structure composed of 49more » layers of GaN/AlN is analyzed as a suitable source of photon pairs having high efficiency.« less

  6. Gamma beams generation with high intensity lasers for two photon Breit-Wheeler pair production

    NASA Astrophysics Data System (ADS)

    D'Humieres, Emmanuel; Ribeyre, Xavier; Jansen, Oliver; Esnault, Leo; Jequier, Sophie; Dubois, Jean-Luc; Hulin, Sebastien; Tikhonchuk, Vladimir; Arefiev, Alex; Toncian, Toma; Sentoku, Yasuhiko

    2017-10-01

    Linear Breit-Wheeler pair creation is the lowest threshold process in photon-photon interaction, controlling the energy release in Gamma Ray Bursts and Active Galactic Nuclei, but it has never been directly observed in the laboratory. Using numerical simulations, we demonstrate the possibility to produce collimated gamma beams with high energy conversion efficiency using high intensity lasers and innovative targets. When two of these beams collide at particular angles, our analytical calculations demonstrate a beaming effect easing the detection of the pairs in the laboratory. This effect has been confirmed in photon collision simulations using a recently developed innovative algorithm. An alternative scheme using Bremsstrahlung radiation produced by next generation high repetition rate laser systems is also being explored and the results of first optimization campaigns in this regime will be presented.

  7. Approach bias for food cues in obese individuals.

    PubMed

    Kemps, Eva; Tiggemann, Marika

    2015-01-01

    This study aimed to investigate the existence of an approach bias for food cues in obese individuals. A community sample of 56 obese women and 56 normal weight controls completed an approach-avoidance variant of the implicit association task. The obese participants were faster to respond to trials that paired food words with approach words, and trials that paired non-food words with avoid words, than the converse pairings, thus, demonstrating an approach bias for food. This bias was evident for both high caloric and low caloric food words, and was not attributable to a state of deprivation or feelings of hunger. By contrast, the normal weight controls did not show any such bias. The results are consistent with recent neurocognitive perspectives of obesity. At a practical level, approach biases for food may present a potential target for modifying (excessive) food intake.

  8. Performance study of single undoped CsI crystals for the Mu2e experiment

    NASA Astrophysics Data System (ADS)

    Donghia, R.; Mu2e Calorimeter Group

    2016-03-01

    The Mu2e experiment at Fermilab aims to measure the neutrinoless muon-to-electron conversion, which is a charged-lepton flavor-violating process. The goal of the experiment is to reach a single event sensitivity of 2.5 × 10^{-17} , to set an upper limit on the muon conversion rate at 6.7 × 10^{-17} in a three-year run. For this purpose, the Mu2e detector is designed to identify electrons from muon conversion and reduce the background to a negligible level. It consists of a low-mass straw tracker and a pure CsI crystal calorimeter. In this paper, the performance of undoped CsI single crystal is reported. Crystals from many vendors have been characterized by determining their Light Yield (LY) and Longitudinal Response Uniformity (LRU), when read with a UV extended PMT, and their time resolution when coupled to a silicon photomultiplier. The crystals show a LY of ˜100 photoelectrons per MeV when wrapped with Tyvek and coupled to the PMT without optical grease. The LRU is well represented by a linear slope that is on average 0.6%/cm. Both measurements have been performed using a ^{22} Na source. The timing performance has been evaluated exploiting cosmic rays, with MPPC readout. A timing resolution lower than 400ps has been achieved (at ˜20{ MeV} , which is the energy released by a minimum ionizing particle in the crystal).

  9. A Novel Performance Evaluation Methodology for Single-Target Trackers.

    PubMed

    Kristan, Matej; Matas, Jiri; Leonardis, Ales; Vojir, Tomas; Pflugfelder, Roman; Fernandez, Gustavo; Nebehay, Georg; Porikli, Fatih; Cehovin, Luka

    2016-11-01

    This paper addresses the problem of single-target tracker performance evaluation. We consider the performance measures, the dataset and the evaluation system to be the most important components of tracker evaluation and propose requirements for each of them. The requirements are the basis of a new evaluation methodology that aims at a simple and easily interpretable tracker comparison. The ranking-based methodology addresses tracker equivalence in terms of statistical significance and practical differences. A fully-annotated dataset with per-frame annotations with several visual attributes is introduced. The diversity of its visual properties is maximized in a novel way by clustering a large number of videos according to their visual attributes. This makes it the most sophistically constructed and annotated dataset to date. A multi-platform evaluation system allowing easy integration of third-party trackers is presented as well. The proposed evaluation methodology was tested on the VOT2014 challenge on the new dataset and 38 trackers, making it the largest benchmark to date. Most of the tested trackers are indeed state-of-the-art since they outperform the standard baselines, resulting in a highly-challenging benchmark. An exhaustive analysis of the dataset from the perspective of tracking difficulty is carried out. To facilitate tracker comparison a new performance visualization technique is proposed.

  10. Attitude sensor alignment calibration for the solar maximum mission

    NASA Technical Reports Server (NTRS)

    Pitone, Daniel S.; Shuster, Malcolm D.

    1990-01-01

    An earlier heuristic study of the fine attitude sensors for the Solar Maximum Mission (SMM) revealed a temperature dependence of the alignment about the yaw axis of the pair of fixed-head star trackers relative to the fine pointing Sun sensor. Here, new sensor alignment algorithms which better quantify the dependence of the alignments on the temperature are developed and applied to the SMM data. Comparison with the results from the previous study reveals the limitations of the heuristic approach. In addition, some of the basic assumptions made in the prelaunch analysis of the alignments of the SMM are examined. The results of this work have important consequences for future missions with stringent attitude requirements and where misalignment variations due to variations in the temperature will be significant.

  11. Wellbeing in the Making: Peoples' Experiences with Wearable Activity Trackers.

    PubMed

    Karapanos, Evangelos; Gouveia, Rúben; Hassenzahl, Marc; Forlizzi, Jodi

    Wearable activity trackers have become a viable business opportunity. Nevertheless, research has raised concerns over their potentially detrimental effects on wellbeing. For example, a recent study found that while counting steps with a pedometer increased steps taken throughout the day, at the same time it decreased the enjoyment people derived from walking. This poses a serious threat to the incorporation of healthy routines into everyday life. Most studies aim at proving the effectiveness of activity trackers. In contrast, a wellbeing-oriented perspective calls for a deeper understanding of how trackers create and mediate meaningful experiences in everyday life. We present a study of real life experiences with three wearable activity trackers: Fitbit , Jawbone Up and Nike  +  Fuelband . Using need fulfillment as a theoretical lens, we study recent, memorable experiences submitted by 133 users of activity trackers. We reveal a two-dimensional structure of users' experience driven by the needs of physical thriving or relatedness. Our qualitative findings further show a nuanced picture of the adoption of activity trackers and their impact on wellbeing. For instance, while reflection about own exercising practices lost its relevance over time, users continued to wear the tracker to document and collect their runs. More than just supporting behavioral change, we find trackers to provide multiple psychological benefits. For instance, they enhance feelings of autonomy as people gain more control about their exercising regime. Others experience relatedness, when family members purchase a tracker for relatives and join them in their efforts towards a better, healthier self. The study highlights that activity trackers can be more than "tools" to change behavior. Through incorporation in daily life, they offer new social experiences, new ways of boosting our self-esteem and getting closer to our ideal selves.

  12. How Accurate Is Your Activity Tracker? A Comparative Study of Step Counts in Low-Intensity Physical Activities

    PubMed Central

    2017-01-01

    Background As commercially available activity trackers are being utilized in clinical trials, the research community remains uncertain about reliability of the trackers, particularly in studies that involve walking aids and low-intensity activities. While these trackers have been tested for reliability during walking and running activities, there has been limited research on validating them during low-intensity activities and walking with assistive tools. Objective The aim of this study was to (1) determine the accuracy of 3 Fitbit devices (ie, Zip, One, and Flex) at different wearing positions (ie, pants pocket, chest, and wrist) during walking at 3 different speeds, 2.5, 5, and 8 km/h, performed by healthy adults on a treadmill; (2) determine the accuracy of the mentioned trackers worn at different sites during activities of daily living; and (3) examine whether intensity of physical activity (PA) impacts the choice of optimal wearing site of the tracker. Methods We recruited 15 healthy young adults to perform 6 PAs while wearing 3 Fitbit devices (ie, Zip, One, and Flex) on their chest, pants pocket, and wrist. The activities include walking at 2.5, 5, and 8 km/h, pushing a shopping cart, walking with aid of a walker, and eating while sitting. We compared the number of steps counted by each tracker with gold standard numbers. We performed multiple statistical analyses to compute descriptive statistics (ie, ANOVA test), intraclass correlation coefficient (ICC), mean absolute error rate, and correlation by comparing the tracker-recorded data with that of the gold standard. Results All the 3 trackers demonstrated good-to-excellent (ICC>0.75) correlation with the gold standard step counts during treadmill experiments. The correlation was poor (ICC<0.60), and the error rate was significantly higher in walker experiment compared to other activities. There was no significant difference between the trackers and the gold standard in the shopping cart experiment. The wrist worn tracker, Flex, counted several steps when eating (P<.01). The chest tracker was identified as the most promising site to capture steps in more intense activities, while the wrist was the optimal wearing site in less intense activities. Conclusions This feasibility study focused on 6 PAs and demonstrated that Fitbit trackers were most accurate when walking on a treadmill and least accurate during walking with a walking aid and for low-intensity activities. This may suggest excluding participants with assistive devices from studies that focus on PA interventions using commercially available trackers. This study also indicates that the wearing site of the tracker is an important factor impacting the accuracy performance. A larger scale study with a more diverse population, various activity tracker vendors, and a larger activity set are warranted to generalize our results. PMID:28801304

  13. The communicative functions of final rises in Finnish intonation.

    PubMed

    Ogden, Richard; Routarinne, Sara

    2005-01-01

    This paper considers the communicative function of final rises in Finnish conversational talk between pairs of teenage girls. Final rises are fairly common, occurring approximately twice a minute, predominantly on declaratives and in narrative sequences. We briefly consider the interplay between voice quality (known to be a marker of transition relevance) and rising intonation in Finnish. We argue that in narrative sequences, rising terminals manage two main interactional tasks: they provide a place for a coparticipant to mark recipiency, and they project more talk by the current speaker. Using a methodology which combines phonetic observation with conversation analysis, we demonstrate participants' orientation to these functions.

  14. Carbon aerogel electrodes for direct energy conversion

    DOEpatents

    Mayer, Steven T.; Kaschmitter, James L.; Pekala, Richard W.

    1997-01-01

    A direct energy conversion device, such as a fuel cell, using carbon aerogel electrodes, wherein the carbon aerogel is loaded with a noble catalyst, such as platinum or rhodium and soaked with phosphoric acid, for example. A separator is located between the electrodes, which are placed in a cylinder having plate current collectors positioned adjacent the electrodes and connected to a power supply, and a pair of gas manifolds, containing hydrogen and oxygen positioned adjacent the current collectors. Due to the high surface area and excellent electrical conductivity of carbon aerogels, the problems relative to high polarization resistance of carbon composite electrodes conventionally used in fuel cells are overcome.

  15. Simple performance evaluation of pulsed spontaneous parametric down-conversion sources for quantum communications.

    PubMed

    Smirr, Jean-Loup; Guilbaud, Sylvain; Ghalbouni, Joe; Frey, Robert; Diamanti, Eleni; Alléaume, Romain; Zaquine, Isabelle

    2011-01-17

    Fast characterization of pulsed spontaneous parametric down conversion (SPDC) sources is important for applications in quantum information processing and communications. We propose a simple method to perform this task, which only requires measuring the counts on the two output channels and the coincidences between them, as well as modeling the filter used to reduce the source bandwidth. The proposed method is experimentally tested and used for a complete evaluation of SPDC sources (pair emission probability, total losses, and fidelity) of various bandwidths. This method can find applications in the setting up of SPDC sources and in the continuous verification of the quality of quantum communication links.

  16. The "Supercritical Pile" Model for GRB: Tapping the Proton Energy and Getting the v F(sub V) Peak at Approx. 1 MeV

    NASA Technical Reports Server (NTRS)

    Kazanas, D.; Georganopoulos, M.; Mastichladis, A.

    2003-01-01

    We propose a process by which the kinetic energy of the protons, that carry most of the energy of GRB relativistic blast waves (RBW) of Lorentz factor is converted explosively into relativistic electrons of the same Lorentz factor, which subsequently produce the observed prompt gamma-ray emission of the burst. This conversion is the result of the combined effects of the reflection of photons produced within the flow by upstream located matter, their re-interception and conversion into e(+) e(-) pairs on the RBW by the p gamma (right arrow) p e(+) e(-) reaction.

  17. Precision Attitude Determination System (PADS) system design and analysis: Single-axis gimbal star tracker

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The feasibility is evaluated of an evolutionary development for use of a single-axis gimbal star tracker from prior two-axis gimbal star tracker based system applications. Detailed evaluation of the star tracker gimbal encoder is considered. A brief system description is given including the aspects of tracker evolution and encoder evaluation. System analysis includes evaluation of star availability and mounting constraints for the geosynchronous orbit application, and a covariance simulation analysis to evaluate performance potential. Star availability and covariance analysis digital computer programs are included.

  18. Impact of deep learning on the normalization of reconstruction kernel effects in imaging biomarker quantification: a pilot study in CT emphysema

    NASA Astrophysics Data System (ADS)

    Jin, Hyeongmin; Heo, Changyong; Kim, Jong Hyo

    2018-02-01

    Differing reconstruction kernels are known to strongly affect the variability of imaging biomarkers and thus remain as a barrier in translating the computer aided quantification techniques into clinical practice. This study presents a deep learning application to CT kernel conversion which converts a CT image of sharp kernel to that of standard kernel and evaluates its impact on variability reduction of a pulmonary imaging biomarker, the emphysema index (EI). Forty cases of low-dose chest CT exams obtained with 120kVp, 40mAs, 1mm thickness, of 2 reconstruction kernels (B30f, B50f) were selected from the low dose lung cancer screening database of our institution. A Fully convolutional network was implemented with Keras deep learning library. The model consisted of symmetric layers to capture the context and fine structure characteristics of CT images from the standard and sharp reconstruction kernels. Pairs of the full-resolution CT data set were fed to input and output nodes to train the convolutional network to learn the appropriate filter kernels for converting the CT images of sharp kernel to standard kernel with a criterion of measuring the mean squared error between the input and target images. EIs (RA950 and Perc15) were measured with a software package (ImagePrism Pulmo, Seoul, South Korea) and compared for the data sets of B50f, B30f, and the converted B50f. The effect of kernel conversion was evaluated with the mean and standard deviation of pair-wise differences in EI. The population mean of RA950 was 27.65 +/- 7.28% for B50f data set, 10.82 +/- 6.71% for the B30f data set, and 8.87 +/- 6.20% for the converted B50f data set. The mean of pair-wise absolute differences in RA950 between B30f and B50f is reduced from 16.83% to 1.95% using kernel conversion. Our study demonstrates the feasibility of applying the deep learning technique for CT kernel conversion and reducing the kernel-induced variability of EI quantification. The deep learning model has a potential to improve the reliability of imaging biomarker, especially in evaluating the longitudinal changes of EI even when the patient CT scans were performed with different kernels.

  19. Layer-Based Approach for Image Pair Fusion.

    PubMed

    Son, Chang-Hwan; Zhang, Xiao-Ping

    2016-04-20

    Recently, image pairs, such as noisy and blurred images or infrared and noisy images, have been considered as a solution to provide high-quality photographs under low lighting conditions. In this paper, a new method for decomposing the image pairs into two layers, i.e., the base layer and the detail layer, is proposed for image pair fusion. In the case of infrared and noisy images, simple naive fusion leads to unsatisfactory results due to the discrepancies in brightness and image structures between the image pair. To address this problem, a local contrast-preserving conversion method is first proposed to create a new base layer of the infrared image, which can have visual appearance similar to another base layer such as the denoised noisy image. Then, a new way of designing three types of detail layers from the given noisy and infrared images is presented. To estimate the noise-free and unknown detail layer from the three designed detail layers, the optimization framework is modeled with residual-based sparsity and patch redundancy priors. To better suppress the noise, an iterative approach that updates the detail layer of the noisy image is adopted via a feedback loop. This proposed layer-based method can also be applied to fuse another noisy and blurred image pair. The experimental results show that the proposed method is effective for solving the image pair fusion problem.

  20. Divorce and infidelity are associated with skewed adult sex ratios in birds.

    PubMed

    Liker, András; Freckleton, Robert P; Székely, Tamás

    2014-04-14

    Adult sex ratio (ASR) is a fundamental concept in population demography, and recent theory suggests that ASR plays a central role in social behavior, mating systems, and parental care. Unbalanced ASRs are predicted to influence pair-bond and mating behavior, since the rarer sex in the population has more potential partners to mate with than the more common sex. Here we use phylogenetic comparative analyses to test whether ASR is related to three major aspects of mating behavior: divorce, social polygamy, and pair-bond infidelity. ASR is strongly correlated with long-term pair bonds, since the divorce rate is higher in species with a female-biased sex ratio, indicating that mate change by pair members and/or breaking of pair bonds by unmated individuals is more frequent when females outnumber males. Short-term pair bonds are also associated with unbalanced ASRs: males are more commonly polygamous when females outnumber males, and conversely, females are more polygamous when males outnumber females. Furthermore, infidelity increases with male-biased ASR in socially monogamous birds, suggesting that male coercion and/or female willingness to cheat the partner are facilitated by male-biased ASR. Our results provide the first comprehensive support for the proposition that ASR influences multiple aspects of pair-bond and mating behavior in wild populations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. A novel adaptive sun tracker for spacecraft solar panel based on hybrid unsymmetric composite laminates

    NASA Astrophysics Data System (ADS)

    Wu, Zhangming; Li, Hao

    2017-11-01

    This paper proposes a novel adaptive sun tracker which is constructed by hybrid unsymmetric composite laminates. The adaptive sun tracker could be applied on spacecraft solar panels to increase their energy efficiency through decreasing the inclined angle between the sunlight and the solar panel normal. The sun tracker possesses a large rotation freedom and its rotation angle depends on the laminate temperature, which is affected by the light condition in the orbit. Both analytical model and finite element model (FEM) are developed for the sun tracker to predict its rotation angle in different light conditions. In this work, the light condition of the geosynchronous orbit on winter solstice is considered in the numerical prediction of the temperatures of the hybrid laminates. The final inclined angle between the sunlight and the solar panel normal during a solar day is computed using the finite element model. Parametric study of the adaptive sun tracker is conducted to improve its capacity and effectiveness of sun tracking. The improved adaptive sun tracker is lightweight and has a state-of-the-art design. In addition, the adaptive sun tracker does not consume any power of the solar panel, since it has no electrical driving devices. The proposed adaptive sun tracker provides a potential alternative to replace the traditional sophisticated electrical driving mechanisms for spacecraft solar panels.

  2. What's the Problem? L2 Learners' Use of the L1 during Consciousness-Raising, Form-Focused Tasks

    ERIC Educational Resources Information Center

    Scott, Virginia M.; de la Fuente, Maria Jose

    2008-01-01

    This qualitative study provides preliminary insight into the role of the first language (L1) when pairs of intermediate-level college learners of French and Spanish are engaged in consciousness-raising, form-focused grammar tasks. Using conversation analysis of audiotaped interactions and stimulated recall sessions, we explored the ways students…

  3. Investigating Negotiation of Meaning in EFL Children with Very Low Levels of Proficiency

    ERIC Educational Resources Information Center

    Lázaro, Amparo; Azpilicueta-Martinez, Raúl

    2015-01-01

    Numerous studies hold that interaction has beneficial effects on second language acquisition among adults and children in second language contexts. However, data from children learning English as a foreign language are still unavailable. In order to fill this research niche, this study examines the conversational interactions of 8 pairs of young…

  4. Conversion to pine: Changes in timing and magnitude of high and low flows.

    Treesearch

    Yusuf Serengil; Wayne T. Swank; Mark S. Riedel; James M. Vose

    2011-01-01

    Understanding watershed responses to extreme events is important for assessing potential impacts of floods, droughts, episodic pollution, and other external driving variables on watershed resources. In this study, we combine trend and frequency analyses with paired watershed techniques to evaluate the long-term high- and low-flow data from Coweeta Hydrologic Laboratory...

  5. Evidence for degenerate tetraploidy in bdelloid rotifers.

    PubMed

    Mark Welch, David B; Mark Welch, Jessica L; Meselson, Matthew

    2008-04-01

    Rotifers of class Bdelloidea have evolved for millions of years apparently without sexual reproduction. We have sequenced 45- to 70-kb regions surrounding the four copies of the hsp82 gene of the bdelloid rotifer Philodina roseola, each of which is on a separate chromosome. The four regions comprise two colinear gene-rich pairs with gene content, order, and orientation conserved within each pair. Only a minority of genes are common to both pairs, also in the same orientation and order, but separated by gene-rich segments present in only one or the other pair. The pattern is consistent with degenerate tetraploidy with numerous segmental deletions, some in one pair of colinear chromosomes and some in the other. Divergence in 1,000-bp windows varies along an alignment of a colinear pair, from zero to as much as 20% in a pattern consistent with gene conversion associated with recombinational repair of DNA double-strand breaks. Although pairs of colinear chromosomes are a characteristic of sexually reproducing diploids and polyploids, a quite different explanation for their presence in bdelloids is suggested by the recent finding that bdelloid rotifers can recover and resume reproduction after suffering hundreds of radiation-induced DNA double-strand breaks per oocyte nucleus. Because bdelloid primary oocytes are in G(1) and therefore lack sister chromatids, we propose that bdelloid colinear chromosome pairs are maintained as templates for the repair of DNA double-strand breaks caused by the frequent desiccation and rehydration characteristic of bdelloid habitats.

  6. Localised and delocalised optically induced conversion of composite glow peak 5 in LiF:Mg,Ti (TLD-100) to glow peak 4 as a function of postirradiation annealing temperature.

    PubMed

    Horowitz, Y S; Einav, Y; Biderman, S; Oster, L

    2002-01-01

    The composite structure of glow peak 5 in LiF:Mg,Ti (TLD-100) has been investigated using optical bleaching by 310 nm (4 eV) light. The glow peak conversion efficiency of peak 5a (Tm = 187 degrees C) to peak 4 traps is very high at a value of 3+/-0.5 (1 SD) whereas the glow peak conversion efficiency of peak 5 (Tm = 205 degrees C) to peak 4 traps is 0.0026+/-0.0012 (1 SD). The high conversion efficiency of peak 5a to peak 4 arises from direct optical ionisation of the electron in the electron-hole pair. leaving behind a singly-trapped hole (peak 4), a direct mechanism, relatively free of competitive mechanisms. Optical ionisation of the 'singly-trapped' electron (peak 5), however, can lead to peak 4 only via multi-stage mechanisms involving charge carrier transport in the valence and conduction bands, a mechanism subject to competitive processes. The conduction/valence band competitive processes lead to the factor of one thousand decrease in the conversion efficiency of peak 5 compared to peak 5a.

  7. Rapid 2D-to-3D conversion

    NASA Astrophysics Data System (ADS)

    Harman, Philip V.; Flack, Julien; Fox, Simon; Dowley, Mark

    2002-05-01

    The conversion of existing 2D images to 3D is proving commercially viable and fulfills the growing need for high quality stereoscopic images. This approach is particularly effective when creating content for the new generation of autostereoscopic displays that require multiple stereo images. The dominant technique for such content conversion is to develop a depth map for each frame of 2D material. The use of a depth map as part of the 2D to 3D conversion process has a number of desirable characteristics: 1. The resolution of the depth may be lower than that of the associated 2D image. 2. It can be highly compressed. 3. 2D compatibility is maintained. 4. Real time generation of stereo, or multiple stereo pairs, is possible. The main disadvantage has been the laborious nature of the manual conversion techniques used to create depth maps from existing 2D images, which results in a slow and costly process. An alternative, highly productive technique has been developed based upon the use of Machine Leaning Algorithm (MLAs). This paper describes the application of MLAs to the generation of depth maps and presents the results of the commercial application of this approach.

  8. Gradient-Type Magnetoelectric Current Sensor with Strong Multisource Noise Suppression.

    PubMed

    Zhang, Mingji; Or, Siu Wing

    2018-02-14

    A novel gradient-type magnetoelectric (ME) current sensor operating in magnetic field gradient (MFG) detection and conversion mode is developed based on a pair of ME composites that have a back-to-back capacitor configuration under a baseline separation and a magnetic biasing in an electrically-shielded and mechanically-enclosed housing. The physics behind the current sensing process is the product effect of the current-induced MFG effect associated with vortex magnetic fields of current-carrying cables (i.e., MFG detection) and the MFG-induced ME effect in the ME composite pair (i.e., MFG conversion). The sensor output voltage is directly obtained from the gradient ME voltage of the ME composite pair and is calibrated against cable current to give the current sensitivity. The current sensing performance of the sensor is evaluated, both theoretically and experimentally, under multisource noises of electric fields, magnetic fields, vibrations, and thermals. The sensor combines the merits of small nonlinearity in the current-induced MFG effect with those of high sensitivity and high common-mode noise rejection rate in the MFG-induced ME effect to achieve a high current sensitivity of 0.65-12.55 mV/A in the frequency range of 10 Hz-170 kHz, a small input-output nonlinearity of <500 ppm, a small thermal drift of <0.2%/℃ in the current range of 0-20 A, and a high common-mode noise rejection rate of 17-28 dB from multisource noises.

  9. Gradient-Type Magnetoelectric Current Sensor with Strong Multisource Noise Suppression

    PubMed Central

    2018-01-01

    A novel gradient-type magnetoelectric (ME) current sensor operating in magnetic field gradient (MFG) detection and conversion mode is developed based on a pair of ME composites that have a back-to-back capacitor configuration under a baseline separation and a magnetic biasing in an electrically-shielded and mechanically-enclosed housing. The physics behind the current sensing process is the product effect of the current-induced MFG effect associated with vortex magnetic fields of current-carrying cables (i.e., MFG detection) and the MFG-induced ME effect in the ME composite pair (i.e., MFG conversion). The sensor output voltage is directly obtained from the gradient ME voltage of the ME composite pair and is calibrated against cable current to give the current sensitivity. The current sensing performance of the sensor is evaluated, both theoretically and experimentally, under multisource noises of electric fields, magnetic fields, vibrations, and thermals. The sensor combines the merits of small nonlinearity in the current-induced MFG effect with those of high sensitivity and high common-mode noise rejection rate in the MFG-induced ME effect to achieve a high current sensitivity of 0.65–12.55 mV/A in the frequency range of 10 Hz–170 kHz, a small input-output nonlinearity of <500 ppm, a small thermal drift of <0.2%/℃ in the current range of 0–20 A, and a high common-mode noise rejection rate of 17–28 dB from multisource noises. PMID:29443920

  10. Validation of an Electronic System for Recording Medical Student Patient Encounters

    PubMed Central

    Nkoy, Flory L.; Petersen, Sarah; Matheny Antommaria, Armand H.; Maloney, Christopher G.

    2008-01-01

    The Liaison Committee for Medical Education requires monitoring of the students’ clinical experiences. Student logs, typically used for this purpose, have a number of limitations. We used an electronic system called Patient Tracker to passively generate student encounter data. The data contained in Patient Tracker was compared to the information reported on student logs and data abstracted from the patients’ charts. Patient Tracker identified 30% more encounters than the student logs. Compared to the student logs, Patient Tracker contained a higher average number of diagnoses per encounter (2.28 vs. 1.03, p<0.01). The diagnostic data contained in Patient Tracker was also more accurate under 4 different definitions of accuracy. Only 1.3% (9/677) of diagnoses in Patient Tracker vs. 16.9% (102/601) diagnoses in the logs could not be validated in patients’ charts (p<0.01). Patient Tracker is a more effective and accurate tool for documenting student clinical encounters than the conventional student logs. PMID:18999155

  11. Novel approach to improve the attitude update rate of a star tracker.

    PubMed

    Zhang, Shuo; Xing, Fei; Sun, Ting; You, Zheng; Wei, Minsong

    2018-03-05

    The star tracker is widely used in attitude control systems of spacecraft for attitude measurement. The attitude update rate of a star tracker is important to guarantee the attitude control performance. In this paper, we propose a novel approach to improve the attitude update rate of a star tracker. The electronic Rolling Shutter (RS) imaging mode of the complementary metal-oxide semiconductor (CMOS) image sensor in the star tracker is applied to acquire star images in which the star spots are exposed with row-to-row time offsets, thereby reflecting the rotation of star tracker at different times. The attitude estimation method with a single star spot is developed to realize the multiple attitude updates by a star image, so as to reach a high update rate. The simulation and experiment are performed to verify the proposed approaches. The test results demonstrate that the proposed approach is effective and the attitude update rate of a star tracker is increased significantly.

  12. How Accurate Is Your Activity Tracker? A Comparative Study of Step Counts in Low-Intensity Physical Activities.

    PubMed

    Alinia, Parastoo; Cain, Chris; Fallahzadeh, Ramin; Shahrokni, Armin; Cook, Diane; Ghasemzadeh, Hassan

    2017-08-11

    As commercially available activity trackers are being utilized in clinical trials, the research community remains uncertain about reliability of the trackers, particularly in studies that involve walking aids and low-intensity activities. While these trackers have been tested for reliability during walking and running activities, there has been limited research on validating them during low-intensity activities and walking with assistive tools. The aim of this study was to (1) determine the accuracy of 3 Fitbit devices (ie, Zip, One, and Flex) at different wearing positions (ie, pants pocket, chest, and wrist) during walking at 3 different speeds, 2.5, 5, and 8 km/h, performed by healthy adults on a treadmill; (2) determine the accuracy of the mentioned trackers worn at different sites during activities of daily living; and (3) examine whether intensity of physical activity (PA) impacts the choice of optimal wearing site of the tracker. We recruited 15 healthy young adults to perform 6 PAs while wearing 3 Fitbit devices (ie, Zip, One, and Flex) on their chest, pants pocket, and wrist. The activities include walking at 2.5, 5, and 8 km/h, pushing a shopping cart, walking with aid of a walker, and eating while sitting. We compared the number of steps counted by each tracker with gold standard numbers. We performed multiple statistical analyses to compute descriptive statistics (ie, ANOVA test), intraclass correlation coefficient (ICC), mean absolute error rate, and correlation by comparing the tracker-recorded data with that of the gold standard. All the 3 trackers demonstrated good-to-excellent (ICC>0.75) correlation with the gold standard step counts during treadmill experiments. The correlation was poor (ICC<0.60), and the error rate was significantly higher in walker experiment compared to other activities. There was no significant difference between the trackers and the gold standard in the shopping cart experiment. The wrist worn tracker, Flex, counted several steps when eating (P<.01). The chest tracker was identified as the most promising site to capture steps in more intense activities, while the wrist was the optimal wearing site in less intense activities. This feasibility study focused on 6 PAs and demonstrated that Fitbit trackers were most accurate when walking on a treadmill and least accurate during walking with a walking aid and for low-intensity activities. This may suggest excluding participants with assistive devices from studies that focus on PA interventions using commercially available trackers. This study also indicates that the wearing site of the tracker is an important factor impacting the accuracy performance. A larger scale study with a more diverse population, various activity tracker vendors, and a larger activity set are warranted to generalize our results. ©Parastoo Alinia, Chris Cain, Ramin Fallahzadeh, Armin Shahrokni, Diane Cook, Hassan Ghasemzadeh. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 11.08.2017.

  13. An analysis of automatic human detection and tracking

    NASA Astrophysics Data System (ADS)

    Demuth, Philipe R.; Cosmo, Daniel L.; Ciarelli, Patrick M.

    2015-12-01

    This paper presents an automatic method to detect and follow people on video streams. This method uses two techniques to determine the initial position of the person at the beginning of the video file: one based on optical flow and the other one based on Histogram of Oriented Gradients (HOG). After defining the initial bounding box, tracking is done using four different trackers: Median Flow tracker, TLD tracker, Mean Shift tracker and a modified version of the Mean Shift tracker using HSV color space. The results of the methods presented in this paper are then compared at the end of the paper.

  14. A multi-hypothesis tracker for clicking whales.

    PubMed

    Baggenstoss, Paul M

    2015-05-01

    This paper describes a tracker specially designed to track clicking beaked whales using widely spaced bottom-mounted hydrophones, although it can be adapted to different species and sensors. The input to the tracker is a sequence of static localization solutions obtained using time difference of arrival information at widely spaced hydrophones. To effectively handle input localizations with high ambiguity, the tracker is based on multi-hypothesis tracker concepts, so it considers all potential association hypotheses and keeps a large number of potential tracks in memory. The method is demonstrated on actual data and shown to successfully track multiple beaked whales at depth.

  15. Apparatus and methods for direct conversion of gaseous hydrocarbons to liquids

    DOEpatents

    Kong, Peter C.; Lessing, Paul A.

    2006-04-25

    A chemical reactor for direct conversion of hydrocarbons includes a dielectric barrier discharge plasma cell and a solid oxide electrochemical cell in fluid communication therewith. The discharge plasma cell comprises a pair of electrodes separated by a dielectric material and passageway therebetween. The electrochemical cell comprises a mixed-conducting solid oxide electrolyte membrane tube positioned between a porous cathode and a porous anode, and a gas inlet tube for feeding oxygen containing gas to the porous cathode. An inlet is provided for feeding hydrocarbons to the passageway of the discharge plasma cell, and an outlet is provided for discharging reaction products from the reactor. A packed bed catalyst may optionally be used in the reactor to increase efficiency of conversion. The reactor can be modified to allow use of a light source for directing ultraviolet light into the discharge plasma cell and the electrochemical cell.

  16. Movement Coordination during Conversation

    PubMed Central

    Latif, Nida; Barbosa, Adriano V.; Vatiokiotis-Bateson, Eric; Castelhano, Monica S.; Munhall, K. G.

    2014-01-01

    Behavioral coordination and synchrony contribute to a common biological mechanism that maintains communication, cooperation and bonding within many social species, such as primates and birds. Similarly, human language and social systems may also be attuned to coordination to facilitate communication and the formation of relationships. Gross similarities in movement patterns and convergence in the acoustic properties of speech have already been demonstrated between interacting individuals. In the present studies, we investigated how coordinated movements contribute to observers’ perception of affiliation (friends vs. strangers) between two conversing individuals. We used novel computational methods to quantify motor coordination and demonstrated that individuals familiar with each other coordinated their movements more frequently. Observers used coordination to judge affiliation between conversing pairs but only when the perceptual stimuli were restricted to head and face regions. These results suggest that observed movement coordination in humans might contribute to perceptual decisions based on availability of information to perceivers. PMID:25119189

  17. Method for direct conversion of gaseous hydrocarbons to liquids

    DOEpatents

    Kong, Peter C.; Lessing, Paul A.

    2006-03-07

    A chemical reactor for direct conversion of hydrocarbons includes a dielectric barrier discharge plasma cell and a solid oxide electrochemical cell in fluid communication therewith. The discharge plasma cell comprises a pair of electrodes separated by a dielectric material and passageway therebetween. The electrochemical cell comprises a mixed-conducting solid oxide electrolyte membrane tube positioned between a porous cathode and a porous anode, and a gas inlet tube for feeding oxygen containing gas to the porous cathode. An inlet is provided for feeding hydrocarbons to the passageway of the discharge plasma cell, and an outlet is provided for discharging reaction products from the reactor. A packed bed catalyst may optionally be used in the reactor to increase efficiency of conversion. The reactor can be modified to allow use of a light source for directing ultraviolet light into the discharge plasma cell and the electrochemical cell.

  18. High-fidelity entanglement swapping and generation of three-qubit GHZ state using asynchronous telecom photon pair sources.

    PubMed

    Tsujimoto, Yoshiaki; Tanaka, Motoki; Iwasaki, Nobuo; Ikuta, Rikizo; Miki, Shigehito; Yamashita, Taro; Terai, Hirotaka; Yamamoto, Takashi; Koashi, Masato; Imoto, Nobuyuki

    2018-01-23

    We experimentally demonstrate a high-fidelity entanglement swapping and a generation of the Greenberger-Horne-Zeilinger (GHZ) state using polarization-entangled photon pairs at telecommunication wavelength produced by spontaneous parametric down conversion with continuous-wave pump light. While spatially separated sources asynchronously emit photon pairs, the time-resolved photon detection guarantees the temporal indistinguishability of photons without active timing synchronizations of pump lasers and/or adjustment of optical paths. In the experiment, photons are sufficiently narrowed by fiber-based Bragg gratings with the central wavelengths of 1541 nm & 1580 nm, and detected by superconducting nanowire single-photon detectors with low timing jitters. The observed fidelities of the final states for entanglement swapping and the generated three-qubit state were 0.84 ± 0.04 and 0.70 ± 0.05, respectively.

  19. Generalized quantum interference of correlated photon pairs.

    PubMed

    Kim, Heonoh; Lee, Sang Min; Moon, Han Seb

    2015-05-07

    Superposition and indistinguishablility between probability amplitudes have played an essential role in observing quantum interference effects of correlated photons. The Hong-Ou-Mandel interference and interferences of the path-entangled photon number state are of special interest in the field of quantum information technologies. However, a fully generalized two-photon quantum interferometric scheme accounting for the Hong-Ou-Mandel scheme and path-entangled photon number states has not yet been proposed. Here we report the experimental demonstrations of the generalized two-photon interferometry with both the interferometric properties of the Hong-Ou-Mandel effect and the fully unfolded version of the path-entangled photon number state using photon-pair sources, which are independently generated by spontaneous parametric down-conversion. Our experimental scheme explains two-photon interference fringes revealing single- and two-photon coherence properties in a single interferometer setup. Using the proposed interferometric measurement, it is possible to directly estimate the joint spectral intensity of a photon pair source.

  20. Multiplying and detecting propagating microwave photons using inelastic Cooper-pair tunneling

    NASA Astrophysics Data System (ADS)

    Leppäkangas, Juha; Marthaler, Michael; Hazra, Dibyendu; Jebari, Salha; Albert, Romain; Blanchet, Florian; Johansson, Göran; Hofheinz, Max

    2018-01-01

    The interaction between propagating microwave fields and Cooper-pair tunneling across a DC-voltage-biased Josephson junction can be highly nonlinear. We show theoretically that this nonlinearity can be used to convert an incoming single microwave photon into an outgoing n -photon Fock state in a different mode. In this process, the electrostatic energy released in a Cooper-pair tunneling event is transferred to the outgoing Fock state, providing energy gain. The created multiphoton Fock state is frequency entangled and highly bunched. The conversion can be made reflectionless (impedance matched) so that all incoming photons are converted to n -photon states. With realistic parameters, multiplication ratios n >2 can be reached. By two consecutive multiplications, the outgoing Fock-state number can get sufficiently large to accurately discriminate it from vacuum with linear postamplification and power measurement. Therefore, this amplification scheme can be used as a single-photon detector without dead time.

  1. Correlation tracking study for meter-class solar telescope on space shuttle. [solar granulation

    NASA Technical Reports Server (NTRS)

    Smithson, R. C.; Tarbell, T. D.

    1977-01-01

    The theory and expected performance level of correlation trackers used to control the pointing of a solar telescope in space using white light granulation as a target were studied. Three specific trackers were modeled and their performance levels predicted for telescopes of various apertures. The performance of the computer model trackers on computer enhanced granulation photographs was evaluated. Parametric equations for predicting tracker performance are presented.

  2. Low-Frequency Error Extraction and Compensation for Attitude Measurements from STECE Star Tracker.

    PubMed

    Lai, Yuwang; Gu, Defeng; Liu, Junhong; Li, Wenping; Yi, Dongyun

    2016-10-12

    The low frequency errors (LFE) of star trackers are the most penalizing errors for high-accuracy satellite attitude determination. Two test star trackers- have been mounted on the Space Technology Experiment and Climate Exploration (STECE) satellite, a small satellite mission developed by China. To extract and compensate the LFE of the attitude measurements for the two test star trackers, a new approach, called Fourier analysis, combined with the Vondrak filter method (FAVF) is proposed in this paper. Firstly, the LFE of the two test star trackers' attitude measurements are analyzed and extracted by the FAVF method. The remarkable orbital reproducibility features are found in both of the two test star trackers' attitude measurements. Then, by using the reproducibility feature of the LFE, the two star trackers' LFE patterns are estimated effectively. Finally, based on the actual LFE pattern results, this paper presents a new LFE compensation strategy. The validity and effectiveness of the proposed LFE compensation algorithm is demonstrated by the significant improvement in the consistency between the two test star trackers. The root mean square (RMS) of the relative Euler angle residuals are reduced from [27.95'', 25.14'', 82.43''], 3σ to [16.12'', 15.89'', 53.27''], 3σ.

  3. Improved gastrointestinal symptom burden after conversion from mycophenolate mofetil to enteric-coated mycophenolate sodium in kidney transplanted children.

    PubMed

    Pape, Lars; Ahlenstiel, Thurid; Kreuzer, Martin; Ehrich, Jochen H H

    2008-09-01

    It has been shown in adult kidney transplant recipients that a conversion from MMF to EC-MPS significantly reduced the GI related symptom burden. No such study exists on children with GI problems while receiving MMF therapy. Ten paediatric kidney transplant recipients (mean age 14.5 yr, s.d. 4.5) receiving triple immunosuppression (Cyclosporin A or Tacrolimus + MMF + Prednisolone) with severe GI symptoms were converted to an equimolar dose of EC-MPS. The GSRS was completed before and at four wk after the switch, and GFR was determined for a mean period of six months. Values were compared by the paired t-test. Mean GSRS improved significantly after the switch to EC-MPS in all but one patient, from 2.1 (s.d. 0.9) to 1.1 (s.d. 0.6). The differences could be found in all four subscales. Graft function did not change after conversion to EC-MPS. In children with moderate or severe GI symptoms while receiving MMF, conversion to EC-MPS led to significantly reduced GI symptoms.

  4. Investigation of thermodynamic parameters in the pyrolysis conversion of biomass and manure to biochars using thermogravimetric analysis.

    PubMed

    Xu, Yiliang; Chen, Baoliang

    2013-10-01

    The thermodynamic parameters of the conversion of two companion pair materials, i.e., rice straw vs dairy manure, and rice bran vs chicken manure, to biochars were characterized by thermogravimetric analysis. The overall changes of activation energy (Ea) were well described by the Flynn-Wall method. The Ea values increased steeply from about 120 to 180 kJ/mol at the mass conversion (α) at 0.2-0.4, followed by a relatively steady change at 0.4<α<0.65, thereafter showed a quick increase at α>0.65. The higher contents of minerals in manures resulted in the larger Ea. The individual conversion of hemicellulose, cellulose and lignin in the feedstocks was identified and their thermodynamic parameters (ΔH°, ΔG° and ΔS°) were calculated. The yields of biochars calculated from TG curve were compared with the determined yields of biochars using muffle pyrolysis. Along with Fourier transform infrared spectra data, the distinct decompositions of biomasses and manures were evaluated. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Double-use linear polarization convertor using hybrid metamaterial based on VO2 phase transition in the terahertz region

    NASA Astrophysics Data System (ADS)

    Zou, Huanling; Xiao, Zhongyin; Li, Wei; Li, Chuan

    2018-04-01

    A number of polarization convertors based on metamaterials(MMs) have been investigated recently, but no one has proposed a high-efficiency linear polarization transformer both in transmission and reflection modes. Here, a bilayered MM embedded with vanadium dioxide (VO2) composed of a pair of sloping gold patches, bottom hybrid layer and a dielectric spacer is proposed as a double-use linear polarization convertor. It has been demonstrated numerically that this device has advantages of switching between transmission polarization conversion and reflection polarization conversion based on the phase transition of the VO2 film in the terahertz (THz) regime and the polarization conversion ratios (PCR) in both cases are higher than 90% in wide bands. The simulated linear polarization transmission/reflection coefficients and the surface current distributions give insight into the mechanism of the linear polarization conversions. Moreover, the physical mechanism of polarization sensitivity of the designed structure is investigated by the distributions of electric field. The proposed double-use linear polarization convertor shows great prospects in polarization imaging, and polarized light communications.

  6. Technology transfer: Imaging tracker to robotic controller

    NASA Technical Reports Server (NTRS)

    Otaguro, M. S.; Kesler, L. O.; Land, Ken; Erwin, Harry; Rhoades, Don

    1988-01-01

    The transformation of an imaging tracker to a robotic controller is described. A multimode tracker was developed for fire and forget missile systems. The tracker locks on to target images within an acquisition window using multiple image tracking algorithms to provide guidance commands to missile control systems. This basic tracker technology is used with the addition of a ranging algorithm based on sizing a cooperative target to perform autonomous guidance and control of a platform for an Advanced Development Project on automation and robotics. A ranging tracker is required to provide the positioning necessary for robotic control. A simple functional demonstration of the feasibility of this approach was performed and described. More realistic demonstrations are under way at NASA-JSC. In particular, this modified tracker, or robotic controller, will be used to autonomously guide the Man Maneuvering Unit (MMU) to targets such as disabled astronauts or tools as part of the EVA Retriever efforts. It will also be used to control the orbiter's Remote Manipulator Systems (RMS) in autonomous approach and positioning demonstrations. These efforts will also be discussed.

  7. Software and mathematical support of Kazakhstani star tracker

    NASA Astrophysics Data System (ADS)

    Akhmedov, D.; Yelubayev, S.; Ten, V.; Bopeyev, T.; Alipbayev, K.; Sukhenko, A.

    2016-10-01

    Currently the specialists of Kazakhstan have been developing the star tracker that is further planned to use on Kazakhstani satellites of various purposes. At the first stage it has been developed the experimental model of star tracker that has following characteristics: field of view 20°, update frequency 2 Hz, exclusion angle 40°, accuracy of attitude determination of optical axis/around optical axis 15/50 arcsec. Software and mathematical support are the most high technology parts of star tracker. The results of software and mathematical support development of experimental model of Kazakhstani star tracker are represented in this article. In particular, there are described the main mathematical models and algorithms that have been used as a basis for program units of preliminary image processing of starry sky, stars identification and star tracker attitude determination. The results of software and mathematical support testing with the help of program simulation complex using various configurations of defects including image sensor noises, point spread function modeling, optical system distortion up to 2% are presented. Analysis of testing results has shown that accuracy of attitude determination of star tracker is within the permissible range

  8. Breadboard stellar tracker system test report, volume 1

    NASA Technical Reports Server (NTRS)

    Kollodge, J. C.; Hubbard, M. W.; Jain, S.; Schons, C. A.

    1981-01-01

    The performance of a star tracker equipped with a focal plane detector was evaluated. The CID board is an array of 256 x 256 pixels which are 20 x 20 micrometers in dimension. The tracker used for test was a breadboard tracker system developed by BASD. Unique acquisition and tracking algorithms are employed to enhance performance. A pattern recognition process is used to test for proper image spread function and to avoid false acquisition on noise. A very linear, high gain, interpixel transfer function is derived for interpolating star position. The lens used in the tracker has an EFL of 100 mm. The tracker has an FOV of 2.93 degrees resulting in a pixel angular subtense of 41.253 arc sec in each axis. The test procedure used for the program presented a star to the tracker in a circular pattern of positions; the pattern was formed by projecting a simulated star through a rotatable deviation wedge. Further tests determined readout noise, Noise Equivalent Displacement during track, and spatial noise during acquisition by taking related data and reducing it.

  9. Optical System Error Analysis and Calibration Method of High-Accuracy Star Trackers

    PubMed Central

    Sun, Ting; Xing, Fei; You, Zheng

    2013-01-01

    The star tracker is a high-accuracy attitude measurement device widely used in spacecraft. Its performance depends largely on the precision of the optical system parameters. Therefore, the analysis of the optical system parameter errors and a precise calibration model are crucial to the accuracy of the star tracker. Research in this field is relatively lacking a systematic and universal analysis up to now. This paper proposes in detail an approach for the synthetic error analysis of the star tracker, without the complicated theoretical derivation. This approach can determine the error propagation relationship of the star tracker, and can build intuitively and systematically an error model. The analysis results can be used as a foundation and a guide for the optical design, calibration, and compensation of the star tracker. A calibration experiment is designed and conducted. Excellent calibration results are achieved based on the calibration model. To summarize, the error analysis approach and the calibration method are proved to be adequate and precise, and could provide an important guarantee for the design, manufacture, and measurement of high-accuracy star trackers. PMID:23567527

  10. Carbon aerogel electrodes for direct energy conversion

    DOEpatents

    Mayer, S.T.; Kaschmitter, J.L.; Pekala, R.W.

    1997-02-11

    A direct energy conversion device, such as a fuel cell, using carbon aerogel electrodes is described, wherein the carbon aerogel is loaded with a noble catalyst, such as platinum or rhodium and soaked with phosphoric acid, for example. A separator is located between the electrodes, which are placed in a cylinder having plate current collectors positioned adjacent the electrodes and connected to a power supply, and a pair of gas manifolds, containing hydrogen and oxygen positioned adjacent the current collectors. Due to the high surface area and excellent electrical conductivity of carbon aerogels, the problems relative to high polarization resistance of carbon composite electrodes conventionally used in fuel cells are overcome. 1 fig.

  11. Realization of the purely spatial Einstein-Podolsky-Rosen paradox in full-field images of spontaneous parametric down-conversion

    NASA Astrophysics Data System (ADS)

    Moreau, Paul-Antoine; Mougin-Sisini, Joé; Devaux, Fabrice; Lantz, Eric

    2012-07-01

    We demonstrate Einstein-Podolsky-Rosen (EPR) entanglement by detecting purely spatial quantum correlations in the near and far fields of spontaneous parametric down-conversion generated in a type-2 beta barium borate crystal. Full-field imaging is performed in the photon-counting regime with an electron-multiplying CCD camera. The data are used without any postselection, and we obtain a violation of Heisenberg inequalities with inferred quantities taking into account all the biphoton pairs in both the near and far fields by integration on the entire two-dimensional transverse planes. This ensures a rigorous demonstration of the EPR paradox in its original position-momentum form.

  12. Relations of Parent-Youth Interactive Exchanges to Adolescent Socioemotional Development

    PubMed Central

    Hutt, Rachel L.; Wang, Qi; Evans, Gary W.

    2013-01-01

    This study examined the relations of parent-youth agreement and disagreement during a joint problem-solving task and multi-methodological indices of socioemotional outcomes in adolescents (Mean age = 13). One hundred and sixty seven parents and their adolescent children participated. Each parent-youth pair played the interactive game Jenga, and their interactions were analyzed for frequency of elaborations (agreement during three or more conversational turns) and negotiations (disagreement during three or more conversational turns). Elaborations during parent-youth interactions were related to less negative classroom behavior, better self-regulation, and more task persistence in youth. Findings are discussed in light of the importance of parent-youth interaction and youth autonomy in adolescent socioemotional development. PMID:24031158

  13. Hydrogenation of carboxylic acids with a homogeneous cobalt catalyst.

    PubMed

    Korstanje, Ties J; van der Vlugt, Jarl Ivar; Elsevier, Cornelis J; de Bruin, Bas

    2015-10-16

    The reduction of esters and carboxylic acids to alcohols is a highly relevant conversion for the pharmaceutical and fine-chemical industries and for biomass conversion. It is commonly performed using stoichiometric reagents, and the catalytic hydrogenation of the acids previously required precious metals. Here we report the homogeneously catalyzed hydrogenation of carboxylic acids to alcohols using earth-abundant cobalt. This system, which pairs Co(BF4)2·6H2O with a tridentate phosphine ligand, can reduce a wide range of esters and carboxylic acids under relatively mild conditions (100°C, 80 bar H2) and reaches turnover numbers of up to 8000. Copyright © 2015, American Association for the Advancement of Science.

  14. Peer-Peer Interaction in a Speaking Test: The Case of the "First Certificate in English" Examination

    ERIC Educational Resources Information Center

    Galaczi, Evelina D.

    2008-01-01

    This discourse-based study turns its attention to paired test-taker discourse in the First Certificate in English speaking test. Its primary aim is to focus on fundamental conversation management concepts, such as overall structural organisation, turn-taking, sequencing, and topic organisation found in the dyadic test-taker interaction in 30 pairs…

  15. Classroom Use of Multimedia-Supported Predict--Observe--Explain Tasks in a Social Constructivist Learning Environment

    ERIC Educational Resources Information Center

    Kearney, Matthew

    2004-01-01

    This paper focuses on the use of multimedia-based predict--observe--explain (POE) tasks to facilitate small group learning conversations. Although the tasks were given to pairs of students as a diagnostic tool to elicit their pre-instructional physics conceptions, they also provided a peer learning opportunity for students. The study adopted a…

  16. Violation of continuous-variable Einstein-Podolsky-Rosen steering with discrete measurements.

    PubMed

    Schneeloch, James; Dixon, P Ben; Howland, Gregory A; Broadbent, Curtis J; Howell, John C

    2013-03-29

    In this Letter, we derive an entropic Einstein-Podolsky-Rosen (EPR) steering inequality for continuous-variable systems using only experimentally measured discrete probability distributions and details of the measurement apparatus. We use this inequality to witness EPR steering between the positions and momenta of photon pairs generated in spontaneous parametric down-conversion. We examine the asymmetry between parties in this inequality, and show that this asymmetry can be used to reduce the technical requirements of experimental setups intended to demonstrate the EPR paradox. Furthermore, we develop a more stringent steering inequality that is symmetric between parties, and use it to show that the down-converted photon pairs also exhibit symmetric EPR steering.

  17. Violation of Continuous-Variable Einstein-Podolsky-Rosen Steering with Discrete Measurements

    NASA Astrophysics Data System (ADS)

    Schneeloch, James; Dixon, P. Ben; Howland, Gregory A.; Broadbent, Curtis J.; Howell, John C.

    2013-03-01

    In this Letter, we derive an entropic Einstein-Podolsky-Rosen (EPR) steering inequality for continuous-variable systems using only experimentally measured discrete probability distributions and details of the measurement apparatus. We use this inequality to witness EPR steering between the positions and momenta of photon pairs generated in spontaneous parametric down-conversion. We examine the asymmetry between parties in this inequality, and show that this asymmetry can be used to reduce the technical requirements of experimental setups intended to demonstrate the EPR paradox. Furthermore, we develop a more stringent steering inequality that is symmetric between parties, and use it to show that the down-converted photon pairs also exhibit symmetric EPR steering.

  18. AIROscope: Ames infrared balloon-borne telescope

    NASA Technical Reports Server (NTRS)

    Koontz, O. L.; Scott, S. G.

    1974-01-01

    A balloon-borne telescope system designed for astronomical observations at infrared wavelengths is discussed. The telescope is gyro-stabilized with updated pointing information derived from television, star tracker, or ground commands. The television system furnishes both course and fine acquisition after initial orientation using a pair of fluxgate servo compasses. Command and control is by a UHF link with 256 commands available. Scientific and engineering data are telemetered to the ground station via narrow band F.M. in the L band. The ground station displays all scientific, engineering and status information during the flights and records the command and telemetry digital bit stream for detailed analysis. The AIROscope telescope has a 28-inch diameter primary mirror and Dall-Kirkham optics. The beam is modulated by oscillating a secondary mirror at 11 or 25 Hz with provision for left or right beam fixed positions by command.

  19. A protocol for evaluating video trackers under real-world conditions.

    PubMed

    Nawaz, Tahir; Cavallaro, Andrea

    2013-04-01

    The absence of a commonly adopted performance evaluation framework is hampering advances in the design of effective video trackers. In this paper, we present a single-score evaluation measure and a protocol to objectively compare trackers. The proposed measure evaluates tracking accuracy and failure, and combines them for both summative and formative performance assessment. The proposed protocol is composed of a set of trials that evaluate the robustness of trackers on a range of test scenarios representing several real-world conditions. The protocol is validated on a set of sequences with a diversity of targets (head, vehicle and person) and challenges (occlusions, background clutter, pose changes and scale changes) using six state-of-the-art trackers, highlighting their strengths and weaknesses on more than 187000 frames. The software implementing the protocol and the evaluation results are made available online and new results can be included, thus facilitating the comparison of trackers.

  20. Determinants for Sustained Use of an Activity Tracker: Observational Study

    PubMed Central

    Moons, Jonas; Kerkhof, Peter; Wiekens, Carina; De Groot, Martijn

    2017-01-01

    Background A lack of physical activity is considered to cause 6% of deaths globally. Feedback from wearables such as activity trackers has the potential to encourage daily physical activity. To date, little research is available on the natural development of adherence to activity trackers or on potential factors that predict which users manage to keep using their activity tracker during the first year (and thereby increasing the chance of healthy behavior change) and which users discontinue using their trackers after a short time. Objective The aim of this study was to identify the determinants for sustained use in the first year after purchase. Specifically, we look at the relative importance of demographic and socioeconomic, psychological, health-related, goal-related, technological, user experience–related, and social predictors of feedback device use. Furthermore, this study tests the effect of these predictors on physical activity. Methods A total of 711 participants from four urban areas in France received an activity tracker (Fitbit Zip) and gave permission to use their logged data. Participants filled out three Web-based questionnaires: at start, after 98 days, and after 232 days to measure the aforementioned determinants. Furthermore, for each participant, we collected activity data tracked by their Fitbit tracker for 320 days. We determined the relative importance of all included predictors by using Random Forest, a machine learning analysis technique. Results The data showed a slow exponential decay in Fitbit use, with 73.9% (526/711) of participants still tracking after 100 days and 16.0% (114/711) of participants tracking after 320 days. On average, participants used the tracker for 129 days. Most important reasons to quit tracking were technical issues such as empty batteries and broken trackers or lost trackers (21.5% of all Q3 respondents, 130/601). Random Forest analysis of predictors revealed that the most influential determinants were age, user experience–related factors, mobile phone type, household type, perceived effect of the Fitbit tracker, and goal-related factors. We explore the role of those predictors that show meaningful differences in the number of days the tracker was worn. Conclusions This study offers an overview of the natural development of the use of an activity tracker, as well as the relative importance of a range of determinants from literature. Decay is exponential but slower than may be expected from existing literature. Many factors have a small contribution to sustained use. The most important determinants are technical condition, age, user experience, and goal-related factors. This finding suggests that activity tracking is potentially beneficial for a broad range of target groups, but more attention should be paid to technical and user experience–related aspects of activity trackers. PMID:29084709

  1. Search for a massive short-lived axion in nuclear transitions

    NASA Astrophysics Data System (ADS)

    Hatzikoutelis, Athanasios

    Recent reports of the possible existence of an Axion with mass = 9.5 MeV and lifetime less than 10-14 sec do not contradict any negative results of the 20-year long search. The present work aims at confirming or disproving these reports. An Axion may compete with M1 nuclear transitions and decay into a e+-e- pair, producing events with high angle separation, thus being detectable in the presence of internal pair conversion which favors small separation angles. In the present experiment the M1 transitions from two discrete states in 12C were produced using a (d,n) reaction. A hermetic array of plastic scintillator detectors for e+-e- pairs from nuclear transitions was upgraded to 65 elements covering 50% of 4pi. A target chamber made of carbon fiber/epoxy resin, with wall thickness 0.8 mm, was introduced which absorbs only 172. 2 keV of the kinetic energy of minimum ionizing e+/e-. A neutron detector with total efficiency of 3% was constructed to measure the time of flight of neutrons. The detectors and chamber were installed on the beam line of the Stony Brook heavy ion LINAC. A test run was conducted using the reaction 11B(p,e+e-)12C (Ep = 7.2 MeV) to populate the Giant Dipole Resonance of 12C. The observation of the IPC from the 22.6-MeV E1 transition to the ground state of 12C established the pair-energy line-shape and produced an absolute pairenergy calibration. The angular correlation distribution of the pairs was found to be in agreement with the Born and point nucleus approximation of E1 angular correlations. A data run with the stripping reaction 11B(d,n)12C* (Ed = 7.2 MeV) populated the (Ipi,T) = (1+,1) 15.11-MeV and the (1 +,0) 12.7-MeV states of 12C. Detected pair events without neutron coincidence required showed a clear and strong peak of the 15.11 MeV to ground state transition. Analysis of these data agreed with angular correlations of M1 internal pair conversion. These did not support the earlier work and showed no evidence of an Axion emitted in the transition. A second test with neutron coincidence required, demonstrated that the full experiment is working as designed. However, for the kinematically complete experiment including neutron coincidence the rate of good events was found to be only 4--6 events/hr. A statistically decisive test will take data runs of about six months.

  2. Optical Alignment of the Global Precipitation Measurement (GPM) Star Trackers

    NASA Technical Reports Server (NTRS)

    Hetherington, Samuel; Osgood, Dean; McMann, Joe; Roberts, Viki; Gill, James; Mclean, Kyle

    2013-01-01

    The optical alignment of the star trackers on the Global Precipitation Measurement (GPM) core spacecraft at NASA Goddard Space Flight Center (GSFC) was challenging due to the layout and structural design of the GPM Lower Bus Structure (LBS) in which the star trackers are mounted as well as the presence of the star tracker shades that blocked line-of-sight to the primary star tracker optical references. The initial solution was to negotiate minor changes in the original LBS design to allow for the installation of a removable item of ground support equipment (GSE) that could be installed whenever measurements of the star tracker optical references were needed. However, this GSE could only be used to measure secondary optical reference cube faces not used by the star tracker vendor to obtain the relationship information and matrix transformations necessary to determine star tracker alignment. Unfortunately, due to unexpectedly large orthogonality errors between the measured secondary adjacent cube faces and the lack of cube calibration data, we required a method that could be used to measure the same reference cube faces as originally measured by the vendor. We describe an alternative technique to theodolite auto-collimation for measurement of an optical reference mirror pointing direction when normal incidence measurements are not possible. This technique was used to successfully align the GPM star trackers and has been used on a number of other NASA flight projects. We also discuss alignment theory as well as a GSFC-developed theodolite data analysis package used to analyze angular metrology data.

  3. Elliptically framed tip-tilt mirror optimized for stellar tracking

    NASA Astrophysics Data System (ADS)

    Clark, James H.; Penado, F. E.; Petak, Jeremy

    2015-09-01

    We compare a design innovation of an elliptically framed tip-tilt optical tracker with an existing circularly framed tracker for the Navy Precision Optical Interferometer. The tracker stabilizes a 12.5 cm stellar beam on a target hundreds of meters away and requires an increase in operational frequency. We reduced mass and size by integrating an elliptical mirror as one of the rotating components, which eliminated a rotating frame. We used the same materials as the existing tracker; however, light-weighted both the aluminum frame and Zerodur® mirror. We generated a computer-aided design model, converted it into a finite element model and performed modal analysis on two load cases. In load case 1, we tied down three points on the bottom surface of the tracker corresponding to the tie-down points of the comparison tracker. This reveals a first mode (lowest) frequency of 140 Hz, a factor of two over the baseline tracker's first mode frequency of 67 Hz. In load case 2, we constrained four additional points inboard of the corners of the tracker base, for a total of seven tie-downs, simulating a firmly bolted and secured mount. The first mode of vibration for this case is 211 Hz, an increase over load case 1 by a factor of 1.5 and more than three times the fundamental frequency of the existing tracker. We conclude that these geometrical changes with the additional tie-down bolts are a viable solution path forward to improve steering speed and recommend a continuation with this effort.

  4. Bisphenol A release from an orthodontic adhesive and its correlation with the degree of conversion on varying light-curing tip distances.

    PubMed

    Sunitha, Catherine; Kailasam, Vignesh; Padmanabhan, Sridevi; Chitharanjan, Arun B

    2011-08-01

    The aims of this research were to use high-performance liquid chromatography to assess the bisphenol A (BPA) released from an orthodontic adhesive (Transbond XT; 3M Unitek, Monrovia, Calif) with various light-curing tip distances and to correlate the release to the degree of conversion. One hundred thirty-eight premolar brackets were divided into 3 groups of 40 each for the high-performance liquid chromatography analysis and 3 groups of 6 each for assessing the degree of conversion. Fourier transform infrared spectroscopy was used for this purpose. Each group was studied at light-curing tip distances of 0, 5, and 10 mm. Statistical analyses were performed by using 2-way analysis of variance (ANOVA), post-hoc multiple comparisons Tukey HSD tests, and paired t tests. Pearson correlation was used to assess the correlation between the degree of conversion and BPA release. BPA release was greater in specimens cured with a greater light-curing tip distance. The degree of conversion decreased with increased light-curing tip distances. A negative correlation was found between BPA release and degree of conversion. Clinicians should ensure that the adhesive is completely cured by keeping the light-curing tip as close to the adhesive as clinically possible. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  5. Biomass for thermochemical conversion: targets and challenges

    PubMed Central

    Tanger, Paul; Field, John L.; Jahn, Courtney E.; DeFoort, Morgan W.; Leach, Jan E.

    2013-01-01

    Bioenergy will be one component of a suite of alternatives to fossil fuels. Effective conversion of biomass to energy will require the careful pairing of advanced conversion technologies with biomass feedstocks optimized for the purpose. Lignocellulosic biomass can be converted to useful energy products via two distinct pathways: enzymatic or thermochemical conversion. The thermochemical pathways are reviewed and potential biotechnology or breeding targets to improve feedstocks for pyrolysis, gasification, and combustion are identified. Biomass traits influencing the effectiveness of the thermochemical process (cell wall composition, mineral and moisture content) differ from those important for enzymatic conversion and so properties are discussed in the language of biologists (biochemical analysis) as well as that of engineers (proximate and ultimate analysis). We discuss the genetic control, potential environmental influence, and consequences of modification of these traits. Improving feedstocks for thermochemical conversion can be accomplished by the optimization of lignin levels, and the reduction of ash and moisture content. We suggest that ultimate analysis and associated properties such as H:C, O:C, and heating value might be more amenable than traditional biochemical analysis to the high-throughput necessary for the phenotyping of large plant populations. Expanding our knowledge of these biomass traits will play a critical role in the utilization of biomass for energy production globally, and add to our understanding of how plants tailor their composition with their environment. PMID:23847629

  6. Validity, reliability and feasibility of commercially available activity trackers in physical therapy for people with a chronic disease: a study protocol of a mixed methods research.

    PubMed

    Beekman, Emmylou; Braun, Susy M; Ummels, Darcy; van Vijven, Kim; Moser, Albine; Beurskens, Anna J

    2017-01-01

    For older people and people with a chronic disease, physical activity provides health benefits. Patients and healthcare professionals can use commercially available activity trackers to objectively monitor (alterations in) activity levels and patterns and to support physical activity. However, insight in the validity, reliability, and feasibility of these trackers in people with a chronic disease is needed. In this article, a study protocol is described in which the validity, reliability (part A), and feasibility from a patient and therapist's point of view (part B) of commercially available activity trackers in daily life and health care is investigated. In part A, a quantitative cross-sectional study, an activity protocol that simulates everyday life activities will be used to determine the validity and reliability of nine commercially available activity trackers. Video recordings will act as the gold standard. In part B, a qualitative participatory action research study will be performed to gain insight in the use of activity trackers in peoples' daily life and therapy settings. Objective feasibility of the activity trackers will be measured with questionnaires, and subjective feasibility (experiences) will be explored in a community of practice. Physical therapists ( n  = 8) will regularly meet during 6 months to learn from each other regarding the actual use of activity trackers in therapy. Therapists and patients ( n  = 48) will decide together which tracker will be used in therapy and for which purpose (e.g., monitoring, goal setting). Data from the therapist' and patients' experiences will be collected by interviews (individual and focus groups) and analyzed by a directed content analysis. At the time of submission, selection of activity trackers, development of the activity protocol, and the ethical approval process are finished. Data collection and data processing are ongoing. The relevance of the study as well as the advantages and disadvantages of several aspects of the chosen design are discussed. The results acquired from both study parts can be used to create decision aids that may assist therapists and people with a chronic disease in choosing a suitable activity tracker, and to facilitate use of these activity trackers in health care settings. Ethical approval has been obtained from two medical-ethical committees (nr. 15-N-109, 15-N-48 and MEC-15-07).

  7. Modelling and Analysis on Biomechanical Dynamic Characteristics of Knee Flexion Movement under Squatting

    PubMed Central

    Wang, Jianping; Tao, Kun; Li, Huanyi; Wang, Chengtao

    2014-01-01

    The model of three-dimensional (3D) geometric knee was built, which included femoral-tibial, patellofemoral articulations and the bone and soft tissues. Dynamic finite element (FE) model of knee was developed to simulate both the kinematics and the internal stresses during knee flexion. The biomechanical experimental system of knee was built to simulate knee squatting using cadaver knees. The flexion motion and dynamic contact characteristics of knee were analyzed, and verified by comparing with the data from in vitro experiment. The results showed that the established dynamic FE models of knee are capable of predicting kinematics and the contact stresses during flexion, and could be an efficient tool for the analysis of total knee replacement (TKR) and knee prosthesis design. PMID:25013852

  8. Power harvesting using PZT ceramics embedded in orthopedic implants.

    PubMed

    Chen, Hong; Liu, Ming; Jia, Chen; Wang, Zihua

    2009-09-01

    Battery lifetime has been the stumbling block for many power-critical or maintenance-free real-time embedded applications, such as wireless sensors and orthopedic implants. Thus a piezoelectric material that could convert human motion into electrical energy provides a very attractive solution for clinical implants. In this work, we analyze the power generation characteristics of stiff lead zirconate titanate (PZT) ceramics and the equivalent circuit through extensive experiments. Our experimental framework allows us to explore many important design considerations of such a PZT-based power generator. Overall we can achieve a PZT element volume of 0.5 x 0.5 x 1.8 cm, which is considerably smaller than the results reported so far. Finally, we outline the application of our PZT elements in a total knee replacement (TKR) implant.

  9. Grumman S2F-1 Tracker at NACA Lewis

    NASA Image and Video Library

    1956-08-21

    The NACA’s Lewis Flight Propulsion Laboratory acquired the Grumman S2F-1 Tracker from the Navy in 1955 to study icing instrumentation. Lewis’s icing research program was winding down at the time. The use of jet engines was increasing thus reducing the threat of ice accumulation. Nonetheless Lewis continued research on the instrumentation used to detect icing conditions. The S2F-1 Tracker was a carrier-based submarine hunter for the Navy. Grumman developed the Tracker as a successor to its Korean War-era Guardian patrol aircraft. Prototypes first flew in late 1952 and battle-ready versions entered Naval service in early 1954. The Navy utilized the Trackers to protect fleets from attack.

  10. Geometric Model for Tracker-Target Look Angles and Line of Slight Distance

    DTIC Science & Technology

    2015-10-20

    412TW-PA-15239 Geometric Model for Tracker -Target Look Angles and Line of Slight Distance DANIEL T. LAIRD AIR FORCE TEST CENTER EDWARDS...15 – 23 OCT 15 4. TITLE AND SUBTITLE Geometric Model for Tracker -Target Look Angles and Line of Slight Distance 5a. CONTRACT...include area code) 661-277-8615 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 GEOMETRIC MODEL FOR TRACKER -TARGET LOOK ANGLES

  11. Integration of an Apple II Plus Computer into an Existing Dual Axis Sun Tracker System.

    DTIC Science & Technology

    1984-06-01

    Identify by block number) S, tpec l Sun Tracker System Solar Energy Apple II Plus Computer 20. ABSTRACT (’ ntlnue on reveree ide If neceesery end...14 4. Dual Axis Sun Tracker (Side View) ----------------- 15 5. Solar Tracker System Block Diagram ---------------- 17 6. Plug Wiring Diagram for Top...sources will be competitive. Already many homes have solar collectors and other devices designed to decrease the consumption of gas, oil, and

  12. The calorimeter of the Mu2e experiment at Fermilab

    DOE PAGES

    Atanov, N.; Baranov, V.; Budagov, J.; ...

    2017-01-23

    Here, the Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: amore » straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10 -4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.« less

  13. Counting Steps in Activities of Daily Living in People With a Chronic Disease Using Nine Commercially Available Fitness Trackers: Cross-Sectional Validity Study.

    PubMed

    Ummels, Darcy; Beekman, Emmylou; Theunissen, Kyra; Braun, Susy; Beurskens, Anna J

    2018-04-02

    Measuring physical activity with commercially available activity trackers is gaining popularity. People with a chronic disease can especially benefit from knowledge about their physical activity pattern in everyday life since sufficient physical activity can contribute to wellbeing and quality of life. However, no validity data are available for this population during activities of daily living. The aim of this study was to investigate the validity of 9 commercially available activity trackers for measuring step count during activities of daily living in people with a chronic disease receiving physiotherapy. The selected activity trackers were Accupedo (Corusen LLC), Activ8 (Remedy Distribution Ltd), Digi-Walker CW-700 (Yamax), Fitbit Flex (Fitbit inc), Lumoback (Lumo Bodytech), Moves (ProtoGeo Oy), Fitbit One (Fitbit inc), UP24 (Jawbone), and Walking Style X (Omron Healthcare Europe BV). In total, 130 persons with chronic diseases performed standardized activity protocols based on activities of daily living that were recorded on video camera and analyzed for step count (gold standard). The validity of the trackers' step count was assessed by correlation coefficients, t tests, scatterplots, and Bland-Altman plots. The correlations between the number of steps counted by the activity trackers and the gold standard were low (range: -.02 to .33). For all activity trackers except for Fitbit One, a significant systematic difference with the gold standard was found for step count. Plots showed a wide range in scores for all activity trackers; Activ8 showed an average overestimation and the other 8 trackers showed underestimations. This study showed that the validity of 9 commercially available activity trackers is low measuring steps while individuals with chronic diseases receiving physiotherapy engage in activities of daily living. ©Darcy Ummels, Emmylou Beekman, Kyra Theunissen, Susy Braun, Anna J Beurskens. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 02.04.2018.

  14. Performance measurement of HARPO: A time projection chamber as a gamma-ray telescope and polarimeter

    NASA Astrophysics Data System (ADS)

    Gros, P.; Amano, S.; Attié, D.; Baron, P.; Baudin, D.; Bernard, D.; Bruel, P.; Calvet, D.; Colas, P.; Daté, S.; Delbart, A.; Frotin, M.; Geerebaert, Y.; Giebels, B.; Götz, D.; Hashimoto, S.; Horan, D.; Kotaka, T.; Louzir, M.; Magniette, F.; Minamiyama, Y.; Miyamoto, S.; Ohkuma, H.; Poilleux, P.; Semeniouk, I.; Sizun, P.; Takemoto, A.; Yamaguchi, M.; Yonamine, R.; Wang, S.

    2018-01-01

    We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e+e- pair-creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections (x, z) and (y, z) of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices and pseudo-tracks exiting from them are identified. We study the various contributions to the single-photon angular resolution using Monte Carlo simulations, compare them with the experimental data and find that they are in excellent agreement. The distribution of the azimuthal angle of pair conversions shows a bias due to the non-cylindrical-symmetric structure of the detector. This bias would average out for a long duration exposure on a space mission, but for this pencil-beam characterisation we have ensured its accurate simulation by a double systematics-control scheme, data taking with the detector rotated at several angles with respect to the beam polarisation direction and systematics control with a non-polarised beam. We measure, for the first time, the polarisation asymmetry of a linearly polarised gamma-ray beam in the low energy pair-creation regime. This sub-GeV energy range is critical for cosmic sources as their spectra are power laws which fall quickly as a function of increasing energy. This work could pave the way to extending polarised gamma-ray astronomy beyond the MeV energy regime.

  15. Efficient 525 nm laser generation in single or double resonant cavity

    NASA Astrophysics Data System (ADS)

    Liu, Shilong; Han, Zhenhai; Liu, Shikai; Li, Yinhai; Zhou, Zhiyuan; Shi, Baosen

    2018-03-01

    This paper reports the results of a study into highly efficient sum frequency generation from 792 and 1556 nm wavelength light to 525 nm wavelength light using either a single or double resonant ring cavity based on a periodically poled potassium titanyl phosphate crystal (PPKTP). By optimizing the cavity's parameters, the maximum power achieved for the resultant 525 nm laser was 263 and 373 mW for the single and double resonant cavity, respectively. The corresponding quantum conversion efficiencies were 8 and 77% for converting 1556 nm photons to 525 nm photons with the single and double resonant cavity, respectively. The measured intra-cavity single pass conversion efficiency for both configurations was about 5%. The performances of the sum frequency generation in these two configurations was studied and compared in detail. This work will provide guidelines for optimizing the generation of sum frequency generated laser light for a variety of configurations. The high conversion efficiency achieved in this work will help pave the way for frequency up-conversion of non-classical quantum states, such as the squeezed vacuum and single photon states. The proposed green laser source will be used in our future experiments, which includes a plan to generate two-color entangled photon pairs and achieve the frequency down-conversion of single photons carrying orbital angular momentum.

  16. Vitamin C supplementation improve the sputum conversion culture rate in pulmonary tuberculosis treatment while rifampicin susceptible

    NASA Astrophysics Data System (ADS)

    Susanto, L.; Siregar, Y.; Kusumawati, L.

    2018-03-01

    The failure of first-line tuberculosis treatment greatly affects multiple drug-resistant tuberculosis. In vitro study of vitamin C induces the death of M. tuberculosis bacteria and accelerates healing of tuberculosis, so the multiple drug-resistant tuberculosis can be avoided. This research aimed to identify the effect of vitamin C as a supportive treatment on the sputum conversion rate. The randomizedand double group with a parallel design by matching pair method was used to collect samples. The first group was treated with standard tuberculosis treatment, and the other was given vitamin C supplementation. Vitamin C plasma level analyzation was performed before and after two months of treatment. Sputum conversion was evaluated every week for eight weeks. The comparison of vitamin C plasma level in pre and post-treatment group was significant (p=0.03) but not in the other group. There was no significant difference in vitamin C plasma level between two groups (p=0.21). The proportion of sputum conversion rate in both group in the first week was 0% vs. 9.6% (p=0.83) and the last week of study was 83.9% vs. 100% (p=0.02). In conclusion, vitamin C supplementation has effects in improving the healing process of tuberculosis patients as indicated by higher in sputum conversion rate.

  17. What are Middle School Students Talking About During Clicker Questions? Characterizing Small-Group Conversations Mediated by Classroom Response Systems

    NASA Astrophysics Data System (ADS)

    Barth-Cohen, Lauren A.; Smith, Michelle K.; Capps, Daniel K.; Lewin, Justin D.; Shemwell, Jonathan T.; Stetzer, MacKenzie R.

    2016-02-01

    There is a growing interest in using classroom response systems or clickers in science classrooms at both the university and K-12 levels. Typically, when instructors use this technology, students are asked to answer and discuss clicker questions with their peers. The existing literature on using clickers at the K-12 level has largely focused on the efficacy of clicker implementation, with few studies investigating collaboration and discourse among students. To expand on this work, we investigated the question: Does clicker use promote productive peer discussion among middle school science students? Specifically, we collected data from middle school students in a physical science course. Students were asked to answer a clicker question individually, discuss the question with their peers, answer the same question again, and then subsequently answer a new matched-pair question individually. We audio recorded the peer conversations to characterize the nature of the student discourse. To analyze these conversations, we used a grounded analysis approach and drew on literature about collaborative knowledge co-construction. The analysis of the conversations revealed that middle school students talked about science content and collaboratively discussed ideas. Furthermore, the majority of conversations, both ones that positively and negatively impacted student performance, contained evidence of collaborative knowledge co-construction.

  18. Bisulfite Conversion of DNA: Performance Comparison of Different Kits and Methylation Quantitation of Epigenetic Biomarkers that Have the Potential to Be Used in Non-Invasive Prenatal Testing

    PubMed Central

    Leontiou, Chrysanthia A.; Hadjidaniel, Michael D.; Mina, Petros; Antoniou, Pavlos; Ioannides, Marios; Patsalis, Philippos C.

    2015-01-01

    Introduction Epigenetic alterations, including DNA methylation, play an important role in the regulation of gene expression. Several methods exist for evaluating DNA methylation, but bisulfite sequencing remains the gold standard by which base-pair resolution of CpG methylation is achieved. The challenge of the method is that the desired outcome (conversion of unmethylated cytosines) positively correlates with the undesired side effects (DNA degradation and inappropriate conversion), thus several commercial kits try to adjust a balance between the two. The aim of this study was to compare the performance of four bisulfite conversion kits [Premium Bisulfite kit (Diagenode), EpiTect Bisulfite kit (Qiagen), MethylEdge Bisulfite Conversion System (Promega) and BisulFlash DNA Modification kit (Epigentek)] regarding conversion efficiency, DNA degradation and conversion specificity. Methods Performance was tested by combining fully methylated and fully unmethylated λ-DNA controls in a series of spikes by means of Sanger sequencing (0%, 25%, 50% and 100% methylated spikes) and Next-Generation Sequencing (0%, 3%, 5%, 7%, 10%, 25%, 50% and 100% methylated spikes). We also studied the methylation status of two of our previously published differentially methylated regions (DMRs) at base resolution by using spikes of chorionic villus sample in whole blood. Results The kits studied showed different but comparable results regarding DNA degradation, conversion efficiency and conversion specificity. However, the best performance was observed with the MethylEdge Bisulfite Conversion System (Promega) followed by the Premium Bisulfite kit (Diagenode). The DMRs, EP6 and EP10, were confirmed to be hypermethylated in the CVS and hypomethylated in whole blood. Conclusion Our findings indicate that the MethylEdge Bisulfite Conversion System (Promega) was shown to have the best performance among the kits. In addition, the methylation level of two of our DMRs, EP6 and EP10, was confirmed. Finally, we showed that bisulfite amplicon sequencing is a suitable approach for methylation analysis of targeted regions. PMID:26247357

  19. Bisulfite Conversion of DNA: Performance Comparison of Different Kits and Methylation Quantitation of Epigenetic Biomarkers that Have the Potential to Be Used in Non-Invasive Prenatal Testing.

    PubMed

    Leontiou, Chrysanthia A; Hadjidaniel, Michael D; Mina, Petros; Antoniou, Pavlos; Ioannides, Marios; Patsalis, Philippos C

    2015-01-01

    Epigenetic alterations, including DNA methylation, play an important role in the regulation of gene expression. Several methods exist for evaluating DNA methylation, but bisulfite sequencing remains the gold standard by which base-pair resolution of CpG methylation is achieved. The challenge of the method is that the desired outcome (conversion of unmethylated cytosines) positively correlates with the undesired side effects (DNA degradation and inappropriate conversion), thus several commercial kits try to adjust a balance between the two. The aim of this study was to compare the performance of four bisulfite conversion kits [Premium Bisulfite kit (Diagenode), EpiTect Bisulfite kit (Qiagen), MethylEdge Bisulfite Conversion System (Promega) and BisulFlash DNA Modification kit (Epigentek)] regarding conversion efficiency, DNA degradation and conversion specificity. Performance was tested by combining fully methylated and fully unmethylated λ-DNA controls in a series of spikes by means of Sanger sequencing (0%, 25%, 50% and 100% methylated spikes) and Next-Generation Sequencing (0%, 3%, 5%, 7%, 10%, 25%, 50% and 100% methylated spikes). We also studied the methylation status of two of our previously published differentially methylated regions (DMRs) at base resolution by using spikes of chorionic villus sample in whole blood. The kits studied showed different but comparable results regarding DNA degradation, conversion efficiency and conversion specificity. However, the best performance was observed with the MethylEdge Bisulfite Conversion System (Promega) followed by the Premium Bisulfite kit (Diagenode). The DMRs, EP6 and EP10, were confirmed to be hypermethylated in the CVS and hypomethylated in whole blood. Our findings indicate that the MethylEdge Bisulfite Conversion System (Promega) was shown to have the best performance among the kits. In addition, the methylation level of two of our DMRs, EP6 and EP10, was confirmed. Finally, we showed that bisulfite amplicon sequencing is a suitable approach for methylation analysis of targeted regions.

  20. Co-training Framework of Generative and Disciminative Trackers with Partial Occlusion Handling

    DTIC Science & Technology

    2011-01-01

    ARO W911NF-06-1-0094. The first author was also supported by the Vietnam Education Foundation. We thank Zdenek Kalal for his help with the P-N Tracker...handling challenging situations with cluttered background. Recently, Kalal et al. [11] proposed the P-N Tracker us- ing positive and negative constraints to...Vietnam Education Foundation. We thank Zdenek Kalal for his help with the P-N Tracker [11]. References [1] A. Adam, E. Rivlin, and I. Shimshoni. Robust

  1. Measuring Scale Errors in a Laser Tracker’s Horizontal Angle Encoder Through Simple Length Measurement and Two-Face System Tests

    PubMed Central

    Muralikrishnan, B.; Blackburn, C.; Sawyer, D.; Phillips, S.; Bridges, R.

    2010-01-01

    We describe a method to estimate the scale errors in the horizontal angle encoder of a laser tracker in this paper. The method does not require expensive instrumentation such as a rotary stage or even a calibrated artifact. An uncalibrated but stable length is realized between two targets mounted on stands that are at tracker height. The tracker measures the distance between these two targets from different azimuthal positions (say, in intervals of 20° over 360°). Each target is measured in both front face and back face. Low order harmonic scale errors can be estimated from this data and may then be used to correct the encoder’s error map to improve the tracker’s angle measurement accuracy. We have demonstrated this for the second order harmonic in this paper. It is important to compensate for even order harmonics as their influence cannot be removed by averaging front face and back face measurements whereas odd orders can be removed by averaging. We tested six trackers from three different manufacturers. Two of those trackers are newer models introduced at the time of writing of this paper. For older trackers from two manufacturers, the length errors in a 7.75 m horizontal length placed 7 m away from a tracker were of the order of ± 65 μm before correcting the error map. They reduced to less than ± 25 μm after correcting the error map for second order scale errors. Newer trackers from the same manufacturers did not show this error. An older tracker from a third manufacturer also did not show this error. PMID:27134789

  2. Counting Steps in Activities of Daily Living in People With a Chronic Disease Using Nine Commercially Available Fitness Trackers: Cross-Sectional Validity Study

    PubMed Central

    Beekman, Emmylou; Theunissen, Kyra; Braun, Susy; Beurskens, Anna J

    2018-01-01

    Background Measuring physical activity with commercially available activity trackers is gaining popularity. People with a chronic disease can especially benefit from knowledge about their physical activity pattern in everyday life since sufficient physical activity can contribute to wellbeing and quality of life. However, no validity data are available for this population during activities of daily living. Objective The aim of this study was to investigate the validity of 9 commercially available activity trackers for measuring step count during activities of daily living in people with a chronic disease receiving physiotherapy. Methods The selected activity trackers were Accupedo (Corusen LLC), Activ8 (Remedy Distribution Ltd), Digi-Walker CW-700 (Yamax), Fitbit Flex (Fitbit inc), Lumoback (Lumo Bodytech), Moves (ProtoGeo Oy), Fitbit One (Fitbit inc), UP24 (Jawbone), and Walking Style X (Omron Healthcare Europe BV). In total, 130 persons with chronic diseases performed standardized activity protocols based on activities of daily living that were recorded on video camera and analyzed for step count (gold standard). The validity of the trackers’ step count was assessed by correlation coefficients, t tests, scatterplots, and Bland-Altman plots. Results The correlations between the number of steps counted by the activity trackers and the gold standard were low (range: –.02 to .33). For all activity trackers except for Fitbit One, a significant systematic difference with the gold standard was found for step count. Plots showed a wide range in scores for all activity trackers; Activ8 showed an average overestimation and the other 8 trackers showed underestimations. Conclusions This study showed that the validity of 9 commercially available activity trackers is low measuring steps while individuals with chronic diseases receiving physiotherapy engage in activities of daily living. PMID:29610110

  3. Individual Differences in the Attribution of Incentive Salience to a Pavlovian Alcohol Cue.

    PubMed

    Villaruel, Franz R; Chaudhri, Nadia

    2016-01-01

    Individual differences exist in the attribution of incentive salience to conditioned stimuli associated with food. Here, we investigated whether individual differences also manifested with a Pavlovian alcohol conditioned stimulus (CS). We compiled data from five experiments that used a Pavlovian autoshaping paradigm and tests of conditioned reinforcement. In all experiments, male, Long-Evans rats with unrestricted access to food and water were acclimated to 15% ethanol. Next, rats received Pavlovian autoshaping training, in which a 10 s presentation of a retractable lever served as the CS and 0.2 mL of 15% ethanol served as the unconditioned stimulus (US). Finally, rats underwent conditioned reinforcement tests in which nose-pokes to an active aperture led to brief presentations of the lever-CS, but nose-pokes to an inactive aperture had no consequence. Rats were categorized as sign-trackers, goal-trackers and intermediates based on a response bias score that reflected their tendencies to sign-track or goal-track at different times during training. We found that distinct groups of rats either consistently interacted with the lever-CS ("sign-trackers") or routinely approached the port during the lever-CS ("goal-trackers") across a majority of the training sessions. However, some individuals ("shifted sign-trackers") with an early tendency to goal-track later shifted to comparable asymptotic levels of sign-tracking as the group identified as sign-trackers. The lever-CS functioned as a conditioned reinforcer for sign-trackers and shifted sign-trackers, but not for goal-trackers. These results provide evidence of robust individual differences in the extent to which a Pavlovian alcohol cue gains incentive salience and functions as a conditioned reinforcer.

  4. Precision Attitude Determination System (PADS) design and analysis. Two-axis gimbal star tracker

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Development of the Precision Attitude Determination System (PADS) focused chiefly on the two-axis gimballed star tracker and electronics design improved from that of Precision Pointing Control System (PPCS), and application of the improved tracker for PADS at geosynchronous altitude. System design, system analysis, software design, and hardware design activities are reported. The system design encompasses the PADS configuration, system performance characteristics, component design summaries, and interface considerations. The PADS design and performance analysis includes error analysis, performance analysis via attitude determination simulation, and star tracker servo design analysis. The design of the star tracker and electronics are discussed. Sensor electronics schematics are included. A detailed characterization of the application software algorithms and computer requirements is provided.

  5. Simulation of ultra-high energy photon propagation with PRESHOWER 2.0

    NASA Astrophysics Data System (ADS)

    Homola, P.; Engel, R.; Pysz, A.; Wilczyński, H.

    2013-05-01

    In this paper we describe a new release of the PRESHOWER program, a tool for Monte Carlo simulation of propagation of ultra-high energy photons in the magnetic field of the Earth. The PRESHOWER program is designed to calculate magnetic pair production and bremsstrahlung and should be used together with other programs to simulate extensive air showers induced by photons. The main new features of the PRESHOWER code include a much faster algorithm applied in the procedures of simulating the processes of gamma conversion and bremsstrahlung, update of the geomagnetic field model, and a minor correction. The new simulation procedure increases the flexibility of the code so that it can also be applied to other magnetic field configurations such as, for example, encountered in the vicinity of the sun or neutron stars. Program summaryProgram title: PRESHOWER 2.0 Catalog identifier: ADWG_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADWG_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 3968 No. of bytes in distributed program, including test data, etc.: 37198 Distribution format: tar.gz Programming language: C, FORTRAN 77. Computer: Intel-Pentium based PC. Operating system: Linux or Unix. RAM:< 100 kB Classification: 1.1. Does the new version supercede the previous version?: Yes Catalog identifier of previous version: ADWG_v1_0 Journal reference of previous version: Comput. Phys. Comm. 173 (2005) 71 Nature of problem: Simulation of a cascade of particles initiated by UHE photon in magnetic field. Solution method: The primary photon is tracked until its conversion into an e+ e- pair. If conversion occurs each individual particle in the resultant preshower is checked for either bremsstrahlung radiation (electrons) or secondary gamma conversion (photons). Reasons for new version: Slow and outdated algorithm in the old version (a significant speed up is possible); Extension of the program to allow simulations also for extraterrestrial magnetic field configurations (e.g. neutron stars) and very long path lengths. Summary of revisions: A veto algorithm was introduced in the gamma conversion and bremsstrahlung tracking procedures. The length of the tracking step is now variable along the track and depends on the probability of the process expected to occur. The new algorithm reduces significantly the number of tracking steps and speeds up the execution of the program. The geomagnetic field model has been updated to IGRF-11, allowing for interpolations up to the year 2015. Numerical Recipes procedures to calculate modified Bessel functions have been replaced with an open source CERN routine DBSKA. One minor bug has been fixed. Restrictions: Gamma conversion into particles other than an electron pair is not considered. Spatial structure of the cascade is neglected. Additional comments: The following routines are supplied in the package, IGRF [1, 2], DBSKA [3], ran2 [4] Running time: 100 preshower events with primary energy 1020 eV require a 2.66 GHz CPU time of about 200 sec.; at the energy of 1021 eV, 600 sec.

  6. Sun tracker for clear or cloudy weather

    NASA Technical Reports Server (NTRS)

    Scott, D. R.; White, P. R.

    1979-01-01

    Sun tracker orients solar collector so that they absorb maximum possible sunlight without being fooled by bright clouds, holes in cloud cover, or other atmospheric conditions. Tracker follows sun within 0.25 deg arc and is accurate within + or - 5 deg when sun is hidden.

  7. Advantages and Limitations of Wearable Activity Trackers: Considerations for Patients and Clinicians.

    PubMed

    Walker, Rachel K; Hickey, Amanda M; Freedson, Patty S

    2016-12-01

    Exercise, light physical activity, and decreased sedentary time all have been associated with health benefits following cancer diagnoses. Commercially available wearable activity trackers may help patients monitor and self-manage their behaviors to achieve these benefits. This article highlights some advantages and limitations clinicians should be aware of when discussing the use of activity trackers with cancer survivors. Limited research has assessed the accuracy of commercially available activity trackers compared to research-grade devices. Because most devices use confidential, proprietary algorithms to convert accelerometry data to meaningful output like total steps, assessing whether these algorithms account for differences in gait abnormalities, functional limitations, and different body morphologies can be difficult. Quantification of sedentary behaviors and light physical activities present additional challenges. The global market for activity trackers is growing, which presents clinicians with a tremendous opportunity to incorporate these devices into clinical practice as tools to promote activity. This article highlights important considerations about tracker accuracy and usage by cancer survivors.

  8. Morphology evolution in high-performance polymer solar cells processed from nonhalogenated solvent

    DOE PAGES

    Cai, Wanzhu; Liu, Peng; Jin, Yaocheng; ...

    2015-05-26

    A new processing protocol based on non-halogenated solvent and additive is developed to produce polymer solar cells with power conversion efficiencies better than those processed from commonly used halogenated solvent-additive pair. Morphology studies show that good performance correlates with a finely distributed nanomorphology with a well-defined polymer fibril network structure, which leads to balanced charge transport in device operation.

  9. Nesting pair density and abundance of ferruginous hawks (Buteo regalis) and golden eagles (Aquila chrysaetos) from aerial surveys in Wyoming

    Treesearch

    Lucretia E. Olson; Robert J. Oakleaf; John R. Squires; Zachary P. Wallace; Patricia L. Kennedy

    2015-01-01

    Raptors that inhabit sagebrush steppe and grassland ecosystems in the western United States may be threatened by continued loss and modification of their habitat due to energy development, conversion to agriculture, and human encroachment. Actions to protect these species are hampered by a lack of reliable data on such basic information as population size and...

  10. Distillation of the two-mode squeezed state.

    PubMed

    Kurochkin, Yury; Prasad, Adarsh S; Lvovsky, A I

    2014-02-21

    We experimentally demonstrate entanglement distillation of the two-mode squeezed state obtained by parametric down-conversion. Applying the photon annihilation operator to both modes, we raise the fraction of the photon-pair component in the state, resulting in the increase of both squeezing and entanglement by about 50%. Because of the low amount of initial squeezing, the distilled state does not experience significant loss of Gaussian character.

  11. Doing Being a Foreign Language Learner in a Classroom: Embodiment of Cognitive States as Social Events

    ERIC Educational Resources Information Center

    Mori, Junko; Hasegawa, Atsushi

    2009-01-01

    Encountering trouble producing a word in the midst of a turn at talk is an everyday experience for foreign language learners. By employing conversation analysis (CA) as a central tool for analysis, the current study explores how students undertake a range of word searches while they organize a pair work session designed for the purpose of language…

  12. Experimental generation of complex noisy photonic entanglement

    NASA Astrophysics Data System (ADS)

    Dobek, K.; Karpiński, M.; Demkowicz-Dobrzański, R.; Banaszek, K.; Horodecki, P.

    2013-02-01

    We present an experimental scheme based on spontaneous parametric down-conversion to produce multiple-photon pairs in maximally entangled polarization states using an arrangement of two type-I nonlinear crystals. By introducing correlated polarization noise in the paths of the generated photons we prepare mixed-entangled states whose properties illustrate fundamental results obtained recently in quantum information theory, in particular those concerning bound entanglement and privacy.

  13. Improved results of LINE-1 methylation analysis in formalin-fixed, paraffin-embedded tissues with the application of a heating step during the DNA extraction process.

    PubMed

    Wen, Xianyu; Jeong, Seorin; Kim, Younghoon; Bae, Jeong Mo; Cho, Nam Yun; Kim, Jung Ho; Kang, Gyeong Hoon

    2017-01-01

    Formalin-fixed, paraffin-embedded (FFPE) tissues are important resources for profiling DNA methylation changes and for studying a variety of diseases. However, formalin fixation introduces inter-strand crosslinking, which might cause incomplete bisulfite conversion of unmethylated cytosines, which might lead to falsely elevated measurements of methylation levels in pyrosequencing assays. Long interspersed nucleotide element-1 (LINE-1) is a major constituent of repetitive transposable DNA elements, and its methylation is referred to correlates with global DNA methylation. To identify whether formalin fixation might impact the measured values of methylation in LINE-1 repetitive elements and whether prolonged heat-induced denaturation of DNA might reduce the artificial increases in measured values caused by formalin fixation, we analyzed paired fresh-frozen (FF) and FFPE xenograft tissue samples for their methylation levels in LINE-1 using a pyrosequencing assay. To further confirm the effect of a heating step in the measurement of LINE-1 or single gene methylation levels, we analyzed FFPE tissue samples of gastric cancer and colorectal cancer for their methylation status in LINE-1 and eight single genes, respectively. Formalin fixation led to an increase in the measured values of LINE-1 methylation regardless of the duration of fixation. Prolonged heating of the DNA at 95 °C for 30 min before bisulfite conversion was found (1) to decrease the discrepancy in the measured values between the paired FF and FFPE tissue samples, (2) to decrease the standard deviation of the measured value of LINE-1 methylation levels in FFPE tissue samples of gastric cancer, and (3) to improve the performance in the measurement of single gene methylation levels in FFPE tissue samples of colorectal cancer. Formalin fixation leads to artificial increases in the measured values of LINE-1 methylation, and the application of prolonged heating of DNA samples decreases the discrepancy in the measured values of LINE-1 methylation between paired FF and FFPE tissue samples. The application of prolonged heating of DNA samples improves bisulfite conversion-based measurement of LINE-1 or single gene methylation levels in FFPE tissue samples.

  14. Has the conversion of natural wetlands to agricultural land increased the incidence and severity of damaging freezes in south Florida?

    USGS Publications Warehouse

    Marshall, C.H.; Pielke, R.A.; Steyaert, L.T.

    2004-01-01

    On several occasions, winter freezes have wrought severe destruction on Florida agriculture. A series of devastating freezes around the turn of the twentieth century, and again during the 1980s, were related to anomalies in the large-scale flow of the ocean–atmosphere system. During the twentieth century, substantial areas of wetlands in south Florida were drained and converted to agricultural land for winter fresh vegetable and sugarcane production. During this time, much of the citrus industry also was relocated to those areas to escape the risk of freeze farther to the north. The purpose of this paper is to present a modeling study designed to investigate whether the conversion of the wetlands to agriculture itself could have resulted in or exacerbated the severity of recent freezes in those agricultural areas of south Florida.For three recent freeze events, a pair of simulations was undertaken with the Regional Atmospheric Modeling System. One member of each pair employed land surface properties that represent pre-1900s (near natural) land cover, whereas the other member of each pair employed data that represent near-current land-use patterns as derived from analysis of Landsat data valid for 1992/93. These two different land cover datasets capture well the conversion of wetlands to agriculture in south Florida during the twentieth century. Use of current land surface properties resulted in colder simulated minimum temperatures and temperatures that remained below freezing for a longer period at locations of key agricultural production centers in south Florida that were once natural wetlands. Examination of time series of the surface energy budget from one of the cases reveals that when natural land cover is used, a persistent moisture flux from the underlying wetlands during the nighttime hours served to prevent the development of below-freezing temperatures at those same locations. When the model results were subjected to an important sensitivity factor, the depth of standing water in the wetlands, the outcome remained consistent. These results provide another example of the potential for humans to perturb the climate system in ways that can have severe socioeconomic consequences by altering the land surface alone.

  15. Spacecraft angular velocity estimation algorithm for star tracker based on optical flow techniques

    NASA Astrophysics Data System (ADS)

    Tang, Yujie; Li, Jian; Wang, Gangyi

    2018-02-01

    An integrated navigation system often uses the traditional gyro and star tracker for high precision navigation with the shortcomings of large volume, heavy weight and high-cost. With the development of autonomous navigation for deep space and small spacecraft, star tracker has been gradually used for attitude calculation and angular velocity measurement directly. At the same time, with the dynamic imaging requirements of remote sensing satellites and other imaging satellites, how to measure the angular velocity in the dynamic situation to improve the accuracy of the star tracker is the hotspot of future research. We propose the approach to measure angular rate with a nongyro and improve the dynamic performance of the star tracker. First, the star extraction algorithm based on morphology is used to extract the star region, and the stars in the two images are matched according to the method of angular distance voting. The calculation of the displacement of the star image is measured by the improved optical flow method. Finally, the triaxial angular velocity of the star tracker is calculated by the star vector using the least squares method. The method has the advantages of fast matching speed, strong antinoise ability, and good dynamic performance. The triaxial angular velocity of star tracker can be obtained accurately with these methods. So, the star tracker can achieve better tracking performance and dynamic attitude positioning accuracy to lay a good foundation for the wide application of various satellites and complex space missions.

  16. Experimental predictions drawn from a computational model of sign-trackers and goal-trackers.

    PubMed

    Lesaint, Florian; Sigaud, Olivier; Clark, Jeremy J; Flagel, Shelly B; Khamassi, Mehdi

    2015-01-01

    Gaining a better understanding of the biological mechanisms underlying the individual variation observed in response to rewards and reward cues could help to identify and treat individuals more prone to disorders of impulsive control, such as addiction. Variation in response to reward cues is captured in rats undergoing autoshaping experiments where the appearance of a lever precedes food delivery. Although no response is required for food to be delivered, some rats (goal-trackers) learn to approach and avidly engage the magazine until food delivery, whereas other rats (sign-trackers) come to approach and engage avidly the lever. The impulsive and often maladaptive characteristics of the latter response are reminiscent of addictive behaviour in humans. In a previous article, we developed a computational model accounting for a set of experimental data regarding sign-trackers and goal-trackers. Here we show new simulations of the model to draw experimental predictions that could help further validate or refute the model. In particular, we apply the model to new experimental protocols such as injecting flupentixol locally into the core of the nucleus accumbens rather than systemically, and lesioning of the core of the nucleus accumbens before or after conditioning. In addition, we discuss the possibility of removing the food magazine during the inter-trial interval. The predictions from this revised model will help us better understand the role of different brain regions in the behaviours expressed by sign-trackers and goal-trackers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. The effect of local anaesthetic wound infiltration on chronic pain after lower limb joint replacement: A protocol for a double-blind randomised controlled trial

    PubMed Central

    2011-01-01

    Background For the majority of patients with osteoarthritis (OA), joint replacement is a successful intervention for relieving chronic joint pain. However, between 10-30% of patients continue to experience chronic pain after joint replacement. Evidence suggests that a risk factor for chronic pain after joint replacement is the severity of acute post-operative pain. The aim of this randomised controlled trial (RCT) is to determine if intra-operative local anaesthethic wound infiltration additional to a standard anaethesia regimen can reduce the severity of joint pain at 12-months after total knee replacement (TKR) and total hip replacement (THR) for OA. Methods 300 TKR patients and 300 THR patients are being recruited into this single-centre double-blind RCT. Participants are recruited before surgery and randomised to either the standard care group or the intervention group. Participants and outcome assessors are blind to treatment allocation throughout the study. The intervention consists of an intra-operative local anaesthetic wound infiltration, consisting of 60 mls of 0.25% bupivacaine with 1 in 200,000 adrenaline. Participants are assessed on the first 5 days post-operative, and then at 3-months, 6-months and 12-months. The primary outcome is the WOMAC Pain Scale, a validated measure of joint pain at 12-months. Secondary outcomes include pain severity during the in-patient stay, post-operative nausea and vomiting, satisfaction with pain relief, length of hospital stay, joint pain and disability, pain sensitivity, complications and cost-effectiveness. A nested qualitative study within the RCT will examine the acceptability and feasibility of the intervention for both patients and healthcare professionals. Discussion Large-scale RCTs assessing the effectiveness of a surgical intervention are uncommon, particulary in orthopaedics. The results from this trial will inform evidence-based recommendations for both short-term and long-term pain management after lower limb joint replacement. If a local anaesthetic wound infiltration is found to be an effective and cost-effective intervention, implementation into clinical practice could improve long-term pain outcomes for patients undergoing lower limb joint replacement. Trial registration Current Controlled Trials ISRCTN96095682 PMID:21352559

  18. Design, analysis, and fabrication of a piezoelectric force plate

    NASA Astrophysics Data System (ADS)

    Hoummadi, Elias; Safaei, Mohsen; Anton, Steven R.

    2017-04-01

    Force plates are used to detect static and dynamic reaction forces due to presence of stationary or moving objects as well as the location of applied forces. The application of force plates in various biomechanical fields, such as gait analysis, has been widely suggested and investigated in the past. Several sensor technologies like piezoelectrics, capacitance gauges, and piezoresistive sensors are utilized to develop force plates with special characteristics. Among the technologies employed in force plate designs, piezoelectrics present the ability of providing a self-powered sensory system. Recently, it has been suggested to implement piezoelectric transducers as sensors in the tibial bearing of total knee replacement (TKR) implants in order to transform the knee bearing into a force plate with the ability to detect force and contact point location for in vivo knee load analysis. Considering this application, a simplified design of a force plate instrumented with six piezoelectric transducers is presented in this study. The force plate is modeled using a finite element (FE) model to investigate the sensing performance of the system. In order to validate the simulation, a prototype force plate is fabricated and tested under the same loading condition applied on the FE model. The results are presented in terms of measured location and amplitude of applied force measured by the piezoelectric transducers. For the FE simulation, the deviation of the measured location of the applied force from the actual location is obtained as 0.62 mm in the x-direction and 0.13 mm in the y-direction, and the error in the amplitude of the measured force is 0.03% of the applied force. On the other hand, the deviation in the measured location of the force from the experimental test is 0.53 mm in the x-direction and 0.1 mm in the y-direction, while the error in force is 3.6% of the applied force. The small quantities of error in both sensed location and amplitude of applied force obtained from the FE simulation and experimental test results demonstrates the potential of the proposed design to be utilized as the sensor in the knee bearing of TKR implants.

  19. Revisiting spatial distribution and biochemical composition of calcium-containing crystals in human osteoarthritic articular cartilage.

    PubMed

    Nguyen, Christelle; Bazin, Dominique; Daudon, Michel; Chatron-Colliet, Aurore; Hannouche, Didier; Bianchi, Arnaud; Côme, Dominique; So, Alexander; Busso, Nathalie; Busso, Nathalie; Lioté, Frédéric; Ea, Hang-Korng

    2013-01-01

    Calcium-containing (CaC) crystals, including basic calcium phosphate (BCP) and calcium pyrophosphate dihydrate (CPP), are associated with destructive forms of osteoarthritis (OA). We assessed their distribution and biochemical and morphologic features in human knee OA cartilage. We prospectively included 20 patients who underwent total knee replacement (TKR) for primary OA. CaC crystal characterization and identification involved Fourier-transform infra-red spectrometry and scanning electron microscopy of 8 to 10 cartilage zones of each knee, including medial and lateral femoral condyles and tibial plateaux and the intercondyle zone. Differential expression of genes involved in the mineralization process between cartilage with and without calcification was assessed in samples from 8 different patients by RT-PCR. Immunohistochemistry and histology studies were performed in 6 different patients. Mean (SEM) age and body mass index of patients at the time of TKR was 74.6 (1.7) years and 28.1 (1.6) kg/m², respectively. Preoperative X-rays showed joint calcifications (chondrocalcinosis) in 4 cases only. The medial femoro-tibial compartment was the most severely affected in all cases, and mean (SEM) Kellgren-Lawrence score was 3.8 (0.1). All 20 OA cartilages showed CaC crystals. The mineral content represented 7.7% (8.1%) of the cartilage weight. All patients showed BCP crystals, which were associated with CPP crystals for 8 joints. CaC crystals were present in all knee joint compartments and in a mean of 4.6 (1.7) of the 8 studied areas. Crystal content was similar between superficial and deep layers and between medial and femoral compartments. BCP samples showed spherical structures, typical of biological apatite, and CPP samples showed rod-shaped or cubic structures. The expression of several genes involved in mineralization, including human homolog of progressive ankylosis, plasma-cell-membrane glycoprotein 1 and tissue-nonspecific alkaline phosphatase, was upregulated in OA chondrocytes isolated from CaC crystal-containing cartilages. CaC crystal deposition is a widespread phenomenon in human OA articular cartilage involving the entire knee cartilage including macroscopically normal and less weight-bearing zones. Cartilage calcification is associated with altered expression of genes involved in the mineralisation process.

  20. Group B Streptococcal Prosthetic Knee Joint Infection Linked to the Consumption of Raw Fish

    PubMed Central

    Law, Gin Way; Wijaya, Limin; Tan, Andrew Hwee Chye

    2017-01-01

    Introduction: Group B Streptococcal (GBS) prosthetic joint infections (PJI) are rare, accounting for only 4.6-6% of primary and revision total knee replacements (TKRs). In 2015, there was an outbreak of GBS infections in Singapore with an association confirmed between consumption of Chinese-style raw fish dishes (snakehead fish, Asian bighead carp) and GBS infection, Type III GBS ST283 strain, affecting more than 200 patients in Singapore. This outbreak is the largest of its kind in the world and also the first time that foodborne transmission of GBS has been proven. We present the first reported case in the literature of a confirmed PJI in a TKR related to foodborne transmission of GBS through consumption of raw fish (Snakehead fish). Case Report: Our patient is a 66-year-old Chinese female admitted with a 24-h history of acute right knee pain and swelling with associated fever in the context of consuming raw fish porridge 3 days before the onset of her symptoms. She had a TKR performed in the same knee 7 years before this presentation. Her GBS PJI was confirmed on both blood and intraoperative tissue/fluid cultures during the outbreak of GBS infections in Singapore. This was managed with debridement, polyethylene liner change, retention of metal prosthesis, and culture-directed antibiotics with good outcomes. Conclusion: Snakehead fish is a popular dish in the Asian community as a traditional remedy to promote wound healing after surgery. Our paper highlights the link between raw fish consumption and invasive GBS causing PJIs. This can occur in healthy adults, even in the absence of gastrointestinal symptoms, despite being a foodborne transmission. Our paper also highlights that GBS PJIs can be managed with debridement, antibiotic therapy, and implant retention with good outcomes in the setting of acute hematogenous infection. We recommend the inclusion of raw fish consumption on history taking in the workup of suspected PJIs and counseling patients preoperatively on the risk of GBS PJIs with the consumption of raw fish dishes (snakehead fish and Asian bighead carp) to mitigate unnecessary PJI risk. PMID:29181355

Top