Sample records for parameters frequency duration

  1. Depth-Duration Frequency of Precipitation for Oklahoma

    USGS Publications Warehouse

    Tortorelli, Robert L.; Rea, Alan; Asquith, William H.

    1999-01-01

    A regional frequency analysis was conducted to estimate the depth-duration frequency of precipitation for 12 durations in Oklahoma (15, 30, and 60 minutes; 1, 2, 3, 6, 12, and 24 hours; and 1, 3, and 7 days). Seven selected frequencies, expressed as recurrence intervals, were investigated (2, 5, 10, 25, 50, 100, and 500 years). L-moment statistics were used to summarize depth-duration data and to determine the appropriate statistical distributions. Three different rain-gage networks provided the data (15minute, 1-hour, and 1-day). The 60-minute, and 1-hour; and the 24-hour, and 1-day durations were analyzed separately. Data were used from rain-gage stations with at least 10-years of record and within Oklahoma or about 50 kilometers into bordering states. Precipitation annual maxima (depths) were determined from the data for 110 15-minute, 141 hourly, and 413 daily stations. The L-moment statistics for depths for all durations were calculated for each station using unbiased L-mo-ment estimators for the mean, L-scale, L-coefficient of variation, L-skew, and L-kur-tosis. The relation between L-skew and L-kurtosis (L-moment ratio diagram) and goodness-of-fit measures were used to select the frequency distributions. The three-parameter generalized logistic distribution was selected to model the frequencies of 15-, 30-, and 60-minute annual maxima; and the three-parameter generalized extreme-value distribution was selected to model the frequencies of 1-hour to 7-day annual maxima. The mean for each station and duration was corrected for the bias associated with fixed interval recording of precipitation amounts. The L-scale and spatially averaged L-skew statistics were used to compute the location, scale, and shape parameters of the selected distribution for each station and duration. The three parameters were used to calculate the depth-duration-frequency relations for each station. The precipitation depths for selected frequencies were contoured from weighted depth surfaces to produce maps from which the precipitation depth-duration-frequency curve for selected storm durations can be determined for any site in Oklahoma.

  2. Time- and frequency-domain parameters of heart rate variability and sympathetic skin response in Parkinson's disease.

    PubMed

    Maetzler, Walter; Karam, Marie; Berger, Monika Fruhmann; Heger, Tanja; Maetzler, Corina; Ruediger, Heinz; Bronzova, Juliana; Lobo, Patricia Pita; Ferreira, Joaquim J; Ziemssen, Tjalf; Berg, Daniela

    2015-03-01

    The autonomic nervous system (ANS) is regularly affected in Parkinson's disease (PD). Information on autonomic dysfunction can be derived from e.g. altered heart rate variability (HRV) and sympathetic skin response (SSR). Such parameters can be quantified easily and measured repeatedly which might be helpful for evaluating disease progression and therapeutic outcome. In this 2-center study, HRV and SSR of 45 PD patients and 26 controls were recorded. HRV was measured during supine metronomic breathing and analyzed in time- and frequency-domains. SSR was evoked by repetitive auditory stimulation. Various ANS parameters were compared (1) between patients and healthy controls, (2) to clinical scales (Unified Parkinson's disease rating scale, Mini-Mental State Examination, Becks Depression Inventory), and (3) to disease duration. Root mean square of successive differences (RMSSD) and low frequency/high frequency (LF/HF) ratio differed significantly between PD and controls. Both, HRV and SSR parameters showed low or no association with clinical scores. Time-domain parameters tended to be affected already at early PD stages but did not consistently change with longer disease duration. In contrast, frequency-domain parameters were not altered in early PD phases but tended to be lower (LF, LF/HF ratio), respectively higher (HF) with increasing disease duration. This report confirms previous results of altered ANS parameters in PD. In addition, it suggests that (1) these ANS parameters are not relevantly associated with motor, behavioral, and cognitive changes in PD, (2) time-domain parameters are useful for the assessment of early PD, and (3) frequency-domain parameters are more closely associated with disease duration.

  3. Systolic blood pressure but not electrocardiogram QRS duration is associated with heart rate variability (HRV): a cross-sectional study in rural Australian non-diabetics.

    PubMed

    Lee, Yvonne Yin Leng; Jelinek, Herbert F; McLachlan, Craig S

    2017-01-01

    A positive correlation between ECG derived QRS duration and heart rate variability (HRV) parameters had previously been reported in young healthy adults. We note this study used a narrow QRS duration range, and did not adjust for systolic blood pressure. Our aims are to investigate associations between systolic blood pressure (SBP), QRS duration and HRV in a rural aging population. A retrospective cross sectional population was obtained from the CSU Diabetes Screening Research Initiative data base where 200 participants had no diabetes or pre-diabetes. SBP data were matched with ECG derived QRS duration and HRV parameters. HRV parameters were calculated from R-R intervals. Resting 12-lead electrocardiograms were obtained from each subject using a Welch Allyn PC-Based ECG system. Pearson correlation analysis revealed no statistically significant associations between HRV parameters and QRS duration. No significant mean differences in HRV parameter subgroups across defined QRS cut-offs were found. SBP > 146 mmHg was associated with increasing QRS durations, however this association disappeared once models were adjusted for age and gender. SBP was also significantly associated with a number of HRV parameters using Pearson correlation analysis, including high frequency (HF) ( p  < 0.05), HFln ( p  < 0.02), RMSDD ( p  < 0.02) and non-linear parameters; ApEN ( p  < 0.001) were negatively correlated with increasing SBP while the low frequency to high frequency ratio (LF/HF) increased with increasing SBP ( p  < 0.03). Our results do not support associations between ECG derived R-R derived HRV parameters and QRS duration in aging populations. We suggest that ventricular conduction as determined by QRS duration is independent of variations in SA-node heart rate variability.

  4. Voice Range Profiles of Singing Students: The Effects of Training Duration and Institution.

    PubMed

    Lycke, Hugo; Siupsinskiene, Nora

    2016-01-01

    The aim of the study was to assess differences in voice parameters measured by the physiological voice range profile (VRP) in groups of vocally healthy subjects differentiated by the duration of vocal training and the training institution. Six basic frequency- and intensity-related VRP parameters and the frequency dip of the register transition zone were determined from VRP recordings of 162 females studying in individual singing lessons (1st-5th level) in Dutch, Belgian, English, and French public or private training facilities. Sixty-seven nonsinging female students served as controls. Singing students in more advanced singing classes demonstrated a significantly greater frequency range, particularly at high frequencies, than did first-year students. Students with private training showed a significantly increased mean intensity range in comparison to those in group classes, while students with musical theater training exhibited significantly increased frequency- and intensity-related VRP parameters in comparison to the students with classical training. When compared to nonsingers, all singing student subgroups showed significant increases in all basic VRP parameters. However, the register transition parameter was not influenced by training duration or institution. Our study suggests that the extension of physiological vocal limits might depend on training duration and institution. © 2016 S. Karger AG, Basel.

  5. Orthogonal design to sift the optimal parameter of Neiguan acupuncture for cerebral infarction

    PubMed Central

    Zhang, Yanan; Yang, Sha; Fan, Xiaonong; Wang, Shu; He, Nina; Li, Lingxin; Luo, Ding; Shi, Xuemin

    2013-01-01

    The individual difference and non-repeatability in acupuncture have not only restricted the development of acupuncture, but have also affected the specificity of acupoints. The present study used instruments to control needle depth, lifting and thrusting frequency, and the duration of acupuncture. Effects of the quantified acupuncture were observed at Neiguan (PC6) with different stimulation parameters. A frequency of 1, 2, or 3 Hz and duration of 5, 60, or 180 seconds were used to observe cerebral blood flow and ratio of infarct volume recovery. Results showed that stimulation at Neiguan with a frequency of 1 Hz and long duration of 180 seconds or 2/3 Hz and long duration of 5/60 seconds significantly increased cerebral blood flow and decreased the ratio of infarct volume. Interactions between frequency and duration play a critical role in quantified acupuncture therapy. PMID:25206575

  6. Source levels and call parameters of harbor seal breeding vocalizations near a terrestrial haulout site in Glacier Bay National Park and Preserve.

    PubMed

    Matthews, Leanna P; Parks, Susan E; Fournet, Michelle E H; Gabriele, Christine M; Womble, Jamie N; Klinck, Holger

    2017-03-01

    Source levels of harbor seal breeding vocalizations were estimated using a three-element planar hydrophone array near the Beardslee Islands in Glacier Bay National Park and Preserve, Alaska. The average source level for these calls was 144 dB RMS re 1 μPa at 1 m in the 40-500 Hz frequency band. Source level estimates ranged from 129 to 149 dB RMS re 1 μPa. Four call parameters, including minimum frequency, peak frequency, total duration, and pulse duration, were also measured. These measurements indicated that breeding vocalizations of harbor seals near the Beardslee Islands of Glacier Bay National Park are similar in duration (average total duration: 4.8 s, average pulse duration: 3.0 s) to previously reported values from other populations, but are 170-220 Hz lower in average minimum frequency (78 Hz).

  7. Optimization of pulsed laser welding process parameters in order to attain minimum underfill and undercut defects in thin 316L stainless steel foils

    NASA Astrophysics Data System (ADS)

    Pakmanesh, M. R.; Shamanian, M.

    2018-02-01

    In this study, the optimization of pulsed Nd:YAG laser welding parameters was done on the lap-joint of a 316L stainless steel foil with the aim of reducing weld defects through response surface methodology. For this purpose, the effects of peak power, pulse-duration, and frequency were investigated. The most important weld defects seen in this method include underfill and undercut. By presenting a second-order polynomial, the above-mentioned statistical method was managed to be well employed to balance the welding parameters. The results showed that underfill increased with the increased power and reduced frequency, it first increased and then decreased with the increased pulse-duration; and the most important parameter affecting it was the power, whose effect was 65%. The undercut increased with the increased power, pulse-duration, and frequency; and the most important parameter affecting it was the power, whose effect was 64%. Finally, by superimposing different responses, improved conditions were presented to attain a weld with no defects.

  8. Scaling of echolocation call parameters in bats.

    PubMed

    Jones, G

    1999-12-01

    I investigated the scaling of echolocation call parameters (frequency, duration and repetition rate) in bats in a functional context. Low-duty-cycle bats operate with search phase cycles of usually less than 20 %. They process echoes in the time domain and are therefore intolerant of pulse-echo overlap. High-duty-cycle (>30 %) species use Doppler shift compensation, and they separate pulse and echo in the frequency domain. Call frequency scales negatively with body mass in at least five bat families. Pulse duration scales positively with mass in low-duty-cycle quasi-constant-frequency (QCF) species because the large aerial-hawking species that emit these signals fly fast in open habitats. They therefore detect distant targets and experience pulse-echo overlap later than do smaller bats. Pulse duration also scales positively with mass in the Hipposideridae, which show at least partial Doppler shift compensation. Pulse repetition rate corresponds closely with wingbeat frequency in QCF bat species that fly relatively slowly. Larger, fast-flying species often skip pulses when detecting distant targets. There is probably a trade-off between call intensity and repetition rate because 'whispering' bats (and hipposiderids) produce several calls per predicted wingbeat and because batches of calls are emitted per wingbeat during terminal buzzes. Severe atmospheric attenuation at high frequencies limits the range of high-frequency calls. Low-duty-cycle bats that call at high frequencies must therefore use short pulses to avoid pulse-echo overlap. Rhinolophids escape this constraint by Doppler shift compensation and, importantly, can exploit advantages associated with the emission of both high-frequency and long-duration calls. Low frequencies are unsuited for the detection of small prey, and low repetition rates may limit prey detection rates. Echolocation parameters may therefore constrain maximum body size in aerial-hawking bats.

  9. Self-stimulation in the rat: quantitative characteristics of the reward pathway.

    PubMed

    Gallistel, C R

    1978-12-01

    Quantitative characteristics of the neural pathway that carries the reinforcing signal in electrical self-stimulation of the brain were established by finding which combinations of stimulation parameters give the same performance in a runway. The reward for each run was a train of evenly spaced monophasic cathodal pulses from a monopolar electrode. With train duration and pulse frequency held constant, the required current was a hyperbolic function of pulse duration, with chronaxie c approximately 1.5 msec. With pulse duration held constant, the required strength of the train (the charge delivered per second) was a hyperbolic function of train duration, with chronaxie C approximately 500 msec. To a first approximation, the values of c and C were independent of the choice either of train duration and pulse frequency or of pulse duration, respectively. Hence, the current intensity required by any choice of train duration, pulse frequency, and pulse duration dependent on only two basic parameters, c and C, and one quantity, Qi, the required impulse charge. These may reflect, respectively, current integration by directly excited neurons; temporal integration of neural activity by synaptic processes in a neural network; and the peak of the impulse response of the network, assuming that the network has linear dynamics and that the reward depends on the peak of the output of the network.

  10. Atlas of depth-duration frequency of precipitation annual maxima for Texas

    USGS Publications Warehouse

    Asquith, William H.; Roussel, Meghan C.

    2004-01-01

    Ninety-six maps depicting the spatial variation of the depth-duration frequency of precipitation annual maxima for Texas are presented. The recurrence intervals represented are 2, 5, 10, 25, 50, 100, 250, and 500 years. The storm durations represented are 15 and 30 minutes; 1, 2, 3, 6, and 12 hours; and 1, 2, 3, 5, and 7 days. The maps were derived using geographically referenced parameter maps of probability distributions used in previously published research by the U.S. Geological Survey to model the magnitude and frequency of precipitation annual maxima for Texas. The maps in this report apply that research and update depth-duration frequency of precipitation maps available in earlier studies done by the National Weather Service.

  11. Effect of elevation on extreme precipitation of short durations: evidences of orographic signature on the parameters of Depth-Duration-Frequency curves

    NASA Astrophysics Data System (ADS)

    Avanzi, Francesco; De Michele, Carlo; Gabriele, Salvatore; Ghezzi, Antonio; Rosso, Renzo

    2015-04-01

    Here, we show how atmospheric circulation and topography rule the variability of depth-duration-frequency (DDF) curves parameters, and we discuss how this variability has physical implications on the formation of extreme precipitations at high elevations. A DDF is a curve ruling the value of the maximum annual precipitation H as a function of duration D and the level of probability F. We consider around 1500 stations over the Italian territory, with at least 20 years of data of maximum annual precipitation depth at different durations. We estimated the DDF parameters at each location by using the asymptotic distribution of extreme values, i.e. the so-called Generalized Extreme Value (GEV) distribution, and considering a statistical simple scale invariance hypothesis. Consequently, a DDF curve depends on five different parameters. A first set relates H with the duration (namely, the mean value of annual maximum precipitation depth for unit duration and the scaling exponent), while a second set links H to F (namely, a scale, position and shape parameter). The value of the shape parameter has consequences on the type of random variable (unbounded, upper or lower bounded). This extensive analysis shows that the variability of the mean value of annual maximum precipitation depth for unit duration obeys to the coupled effect of topography and modal direction of moisture flux during extreme events. Median values of this parameter decrease with elevation. We called this phenomenon "reverse orographic effect" on extreme precipitation of short durations, since it is in contrast with general knowledge about the orographic effect on mean precipitation. Moreover, the scaling exponent is mainly driven by topography alone (with increasing values of this parameter at increasing elevations). Therefore, the quantiles of H(D,F) at durations greater than unit turn to be more variable at high elevations than at low elevations. Additionally, the analysis of the variability of the shape parameter with elevation shows that extreme events at high elevations appear to be distributed according to an upper bounded probability distribution. These evidences could be a characteristic sign of the formation of extreme precipitation events at high elevations.

  12. [Perception and selectivity of sound duration in the central auditory midbrain].

    PubMed

    Wang, Xin; Li, An-An; Wu, Fei-Jian

    2010-08-25

    Sound duration plays important role in acoustic communication. Information of acoustic signal is mainly encoded in the amplitude and frequency spectrum of different durations. Duration selective neurons exist in the central auditory system including inferior colliculus (IC) of frog, bat, mouse and chinchilla, etc., and they are important in signal recognition and feature detection. Two generally accepted models, which are "coincidence detector model" and "anti-coincidence detector model", have been raised to explain the mechanism of neural selective responses to sound durations based on the study of IC neurons in bats. Although they are different in details, they both emphasize the importance of synaptic integration of excitatory and inhibitory inputs, and are able to explain the responses of most duration-selective neurons. However, both of the hypotheses need to be improved since other sound parameters, such as spectral pattern, amplitude and repetition rate, could affect the duration selectivity of the neurons. The dynamic changes of sound parameters are believed to enable the animal to effectively perform recognition of behavior related acoustic signals. Under free field sound stimulation, we analyzed the neural responses in the IC and auditory cortex of mouse and bat to sounds with different duration, frequency and amplitude, using intracellular or extracellular recording techniques. Based on our work and previous studies, this article reviews the properties of duration selectivity in central auditory system and discusses the mechanisms of duration selectivity and the effect of other sound parameters on the duration coding of auditory neurons.

  13. Associations of physical activity duration, frequency, and load with volumetric BMD, geometry, and bone strength in young girls

    PubMed Central

    Farr, Joshua N.; Blew, Robert M.; Lee, Vinson R.; Lohman, Timothy G.; Going, Scott B.

    2011-01-01

    Purpose This study evaluated the associations of physical activity (PA) duration, frequency, load, and their interaction (total PA score = duration × frequency × load) with volumetric bone mineral density, geometry, and indices of bone strength in young girls. Methods 465 girls (aged 8–13 years) completed a past year physical activity questionnaire (PYPAQ) which inquires about the frequency (days/week) and duration (average minutes/session) of leisure-time PA and sports. Load (peak strain score) values were assigned to each activity based on ground reaction forces. Peripheral quantitative computed tomography was used to assess bone parameters at metaphyseal and diaphyseal sites of the femur and tibia of the non-dominant leg. Results Correlations across all skeletal sites between PA duration, frequency, load and periosteal circumference (PC), bone strength index (BSI), and strength-strain index (SSI) were significant (p ≤ 0.05), although low (0.10–0.17). A 2.7–3.7% greater PC across all skeletal sites was associated with a high compared to a low PYPAQ score. Also, a high PYPAQ score was associated with greater BSI (6.5–8.7%) at metaphyseal sites and SSI (7.5–8.1%) at diaphyseal sites of the femur and tibia. The effect of a low PYPAQ score on bone geometric parameters and strength was greater than a high PYPAQ score. Conclusions PA duration, frequency, and load were all associated with bone geometry and strength, although their independent influences were modest and site specific. Low levels of PA may compromise bone development whereas high levels have only a small benefit over more average levels. PMID:20694457

  14. Exercise training dose differentially alters muscle and heart capillary density and metabolic functions in an obese rat with metabolic syndrome.

    PubMed

    Machado, Marcus Vinicius; Vieira, Aline Bomfim; da Conceição, Fabiana Gomes; Nascimento, Alessandro Rodrigues; da Nóbrega, Antonio Claudio Lucas; Tibirica, Eduardo

    2017-12-01

    What is the central question of this study? Regular exercise is recommended as a non-pharmacological approach for the prevention and treatment of metabolic syndrome. However, the impact of different combinations of intensity, duration and frequency of exercise on metabolic syndrome and microvascular density has not been reported. What is the main finding and its importance? We provide evidence on the impact of aerobic exercise dose on metabolic and microvascular alterations in an experimental model of metabolic syndrome induced by high-fat diet. We found that the exercise frequency and duration were the main factors affecting anthropometric and metabolic parameters and microvascular density in the skeletal muscle. Exercise intensity was related only to microvascular density in the heart. We evaluated the effect of the frequency, duration and intensity of exercise training on metabolic parameters and structural capillary density in obese rats with metabolic syndrome. Wistar-Kyoto rats were fed either a standard commercial diet (CON) or a high-fat diet (HFD). Animals that received the HFD were randomly separated into either a sedentary (SED) group or eight different exercise groups that varied according to the frequency, duration and intensity of training. After 12 weeks of aerobic exercise training, the body composition, aerobic capacity, haemodynamic variables, metabolic parameters and capillary density in the heart and skeletal muscle were evaluated. All the exercise training groups showed reduced resting systolic blood pressure and heart rate and normalized fasting glucose. The minimal amount of exercise (90 min per week) produced little effect on metabolic syndrome parameters. A moderate amount of exercise (150 min per week) was required to reduce body weight and improve capillary density. However, only the high amount of exercise (300 min per week) significantly reduced the amount of body fat depots. The three-way ANOVA showed a main effect of exercise frequency and duration for the improvement of metabolic syndrome and capillary density in skeletal muscle. Exercise intensity was a main factor in reversing microvascular rarefaction in the heart. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.

  15. Variation of consumer contact with household products: a preliminary investigation.

    PubMed

    Weegels, M E; van Veen, M P

    2001-06-01

    Little information is available on product use by consumers, which severely hampers exposure estimation for consumer products. This article describes actual contact with several consumer products, specifically dishwashing detergents, cleaning products, and hair styling products. How and where products are handled, as well as the duration, frequency, and amount of use were studied by means of diaries, in-home observations, and measurements. This study addressed the question, "To what extent are frequency, duration, and amount of use associated?" Findings showed that there was a large intra- as well as interindividual variation in frequency, duration, and amount of use, with the interindividual variation being considerably larger. At the same time, results showed that, for a given activity, users tended to follow their own routine. Few relations were found among frequency, duration, and amount of use. It was concluded that among persons, frequency, duration, and amount of product act in practice as independent parameters. Diaries appear to be quite suitable for gaining insight into frequently used products. Observations of usage, recorded on video, were indispensable for obtaining particular information on product use. In addition, home visits enabled the collection of specific measurements. Although diaries and home visits are time-consuming, the combination provided insight into variation as well as relations among frequency, duration, and amount of use.

  16. To use or not to use? Compulsive behavior and its role in smartphone addiction

    PubMed Central

    Lin, Y-H; Lin, Y-C; Lin, S-H; Lee, Y-H; Lin, P-H; Chiang, C-L; Chang, L-R; Yang, C C H; Kuo, T B J

    2017-01-01

    Global smartphone penetration has led to unprecedented addictive behaviors. To develop a smartphone use/non-use pattern by mobile application (App) in order to identify problematic smartphone use, a total of 79 college students were monitored by the App for 1 month. The App-generated parameters included the daily use/non-use frequency, the total duration and the daily median of the duration per epoch. We introduced two other parameters, the root mean square of the successive differences (RMSSD) and the Similarity Index, in order to explore the similarity in use and non-use between participants. The non-use frequency, non-use duration and non-use-median parameters were able to significantly predict problematic smartphone use. A lower value for the RMSSD and Similarity Index, which represent a higher use/non-use similarity, were also associated with the problematic smartphone use. The use/non-use similarity is able to predict problematic smartphone use and reach beyond just determining whether a person shows excessive use. PMID:28195570

  17. To use or not to use? Compulsive behavior and its role in smartphone addiction.

    PubMed

    Lin, Y-H; Lin, Y-C; Lin, S-H; Lee, Y-H; Lin, P-H; Chiang, C-L; Chang, L-R; Yang, C C H; Kuo, T B J

    2017-02-14

    Global smartphone penetration has led to unprecedented addictive behaviors. To develop a smartphone use/non-use pattern by mobile application (App) in order to identify problematic smartphone use, a total of 79 college students were monitored by the App for 1 month. The App-generated parameters included the daily use/non-use frequency, the total duration and the daily median of the duration per epoch. We introduced two other parameters, the root mean square of the successive differences (RMSSD) and the Similarity Index, in order to explore the similarity in use and non-use between participants. The non-use frequency, non-use duration and non-use-median parameters were able to significantly predict problematic smartphone use. A lower value for the RMSSD and Similarity Index, which represent a higher use/non-use similarity, were also associated with the problematic smartphone use. The use/non-use similarity is able to predict problematic smartphone use and reach beyond just determining whether a person shows excessive use.

  18. Weakfish sonic muscle: influence of size, temperature and season.

    PubMed

    Connaughton, M A; Fine, M L; Taylor, M H

    2002-08-01

    The influence of temperature, size and season on the sounds produced by the sonic muscles of the weakfish Cynoscion regalis are categorized and used to formulate a hypothesis about the mechanism of sound generation by the sonic muscle and swimbladder. Sounds produced by male weakfish occur at the time and location of spawning and have been observed in courtship in captivity. Each call includes a series of 6-10 sound pulses, and each pulse expresses a damped, 2-3 cycle acoustic waveform generated by single simultaneous twitches of the bilateral sonic muscles. The sonic muscles triple in mass during the spawning season, and this hypertrophy is initiated by rising testosterone levels that trigger increases in myofibrillar and sarcoplasmic cross-sectional area of sonic muscle fibers. In response to increasing temperature, sound pressure level (SPL), dominant frequency and repetition rate increase, and pulse duration decreases. Likewise, SPL and pulse duration increase and dominant frequency decreases with fish size. Changes in acoustic parameters with fish size suggest the possibility that drumming sounds act as an 'honest' signal of male fitness during courtship. These parameters also correlate with seasonally increasing sonic muscle mass. We hypothesize that sonic muscle twitch duration rather than the resonant frequency of the swimbladder determines dominant frequency. The brief (3.5 ms), rapidly decaying acoustic pulses reflect a low-Q, broadly tuned resonator, suggesting that dominant frequency is determined by the forced response of the swimbladder to sonic muscle contractions. The changing dominant frequency with temperature in fish of the same size further suggests that frequency is not determined by the natural frequency of the bladder because temperature is unlikely to affect resonance. Finally, dominant frequency correlates with pulse duration (reflecting muscle twitch duration), and the inverse of the period of the second cycle of acoustic energy approximates the recorded frequency. This paper demonstrates for the first time that the dominant frequency of a fish sound produced by a single muscle twitch is apparently determined by the velocity of the muscle twitch rather than the natural frequency of the swimbladder.

  19. Frequency distributions and correlations of solar X-ray flare parameters

    NASA Technical Reports Server (NTRS)

    Crosby, Norma B.; Aschwanden, Markus J.; Dennis, Brian R.

    1993-01-01

    Frequency distributions of flare parameters are determined from over 12,000 solar flares. The flare duration, the peak counting rate, the peak hard X-ray flux, the total energy in electrons, and the peak energy flux in electrons are among the parameters studied. Linear regression fits, as well as the slopes of the frequency distributions, are used to determine the correlations between these parameters. The relationship between the variations of the frequency distributions and the solar activity cycle is also investigated. Theoretical models for the frequency distribution of flare parameters are dependent on the probability of flaring and the temporal evolution of the flare energy build-up. The results of this study are consistent with stochastic flaring and exponential energy build-up. The average build-up time constant is found to be 0.5 times the mean time between flares.

  20. The pitch of short-duration fundamental frequency glissandos.

    PubMed

    d'Alessandro, C; Rosset, S; Rossi, J P

    1998-10-01

    Pitch perception for short-duration fundamental frequency (F0) glissandos was studied. In the first part, new measurements using the method of adjustment are reported. Stimuli were F0 glissandos centered at 220 Hz. The parameters under study were: F0 glissando extents (0, 0.8, 1.5, 3, 6, and 12 semitones, i.e., 0, 10.17, 18.74, 38.17, 76.63, and 155.56 Hz), F0 glissando durations (50, 100, 200, and 300 ms), F0 glissando directions (rising or falling), and the extremity of F0 glissandos matched (beginning or end). In the second part, the main results are discussed: (1) perception seems to correspond to an average of the frequencies present in the vicinity of the extremity matched; (2) the higher extremities of the glissando seem more important; (3) adjustments at the end are closer to the extremities than adjustments at the beginning. In the third part, numerical models accounting for the experimental data are proposed: a time-average model and a weighted time-average model. Optimal parameters for these models are derived. The weighted time-average model achieves a 94% accurate prediction rate for the experimental data. The numerical model is successful in predicting the pitch of short-duration F0 glissandos.

  1. Effects of metric hierarchy and rhyme predictability on word duration in The Cat in the Hat.

    PubMed

    Breen, Mara

    2018-05-01

    Word durations convey many types of linguistic information, including intrinsic lexical features like length and frequency and contextual features like syntactic and semantic structure. The current study was designed to investigate whether hierarchical metric structure and rhyme predictability account for durational variation over and above other features in productions of a rhyming, metrically-regular children's book: The Cat in the Hat (Dr. Seuss, 1957). One-syllable word durations and inter-onset intervals were modeled as functions of segment number, lexical frequency, word class, syntactic structure, repetition, and font emphasis. Consistent with prior work, factors predicting longer word durations and inter-onset intervals included more phonemes, lower frequency, first mention, alignment with a syntactic boundary, and capitalization. A model parameter corresponding to metric grid height improved model fit of word durations and inter-onset intervals. Specifically, speakers realized five levels of metric hierarchy with inter-onset intervals such that interval duration increased linearly with increased height in the metric hierarchy. Conversely, speakers realized only three levels of metric hierarchy with word duration, demonstrating that they shortened the highly predictable rhyme resolutions. These results further understanding of the factors that affect spoken word duration, and demonstrate the myriad cues that children receive about linguistic structure from nursery rhymes. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Behavioral assessment of sensitivity to intracortical microstimulation of primate somatosensory cortex.

    PubMed

    Kim, Sungshin; Callier, Thierri; Tabot, Gregg A; Gaunt, Robert A; Tenore, Francesco V; Bensmaia, Sliman J

    2015-12-08

    Intracortical microstimulation (ICMS) is a powerful tool to investigate the functional role of neural circuits and may provide a means to restore sensation for patients for whom peripheral stimulation is not an option. In a series of psychophysical experiments with nonhuman primates, we investigate how stimulation parameters affect behavioral sensitivity to ICMS. Specifically, we deliver ICMS to primary somatosensory cortex through chronically implanted electrode arrays across a wide range of stimulation regimes. First, we investigate how the detectability of ICMS depends on stimulation parameters, including pulse width, frequency, amplitude, and pulse train duration. Then, we characterize the degree to which ICMS pulse trains that differ in amplitude lead to discriminable percepts across the range of perceptible and safe amplitudes. We also investigate how discriminability of pulse amplitude is modulated by other stimulation parameters-namely, frequency and duration. Perceptual judgments obtained across these various conditions will inform the design of stimulation regimes for neuroscience and neuroengineering applications.

  3. Optimal all-optical switching of a microcavity resonance in the telecom range using the electronic Kerr effect.

    PubMed

    Yüce, Emre; Ctistis, Georgios; Claudon, Julien; Gérard, Jean-Michel; Vos, Willem L

    2016-01-11

    We have switched GaAs/AlAs and AlGaAs/AlAs planar microcavities that operate in the "Original" (O) telecom band by exploiting the instantaneous electronic Kerr effect. We observe that the resonance frequency reversibly shifts within one picosecond when the nanostructure is pumped with low-energy photons. We investigate experimentally and theoretically the role of several parameters: the material backbone and its electronic bandgap, the quality factor, and the duration of the switch pulse. The magnitude of the frequency shift is reduced when the backbone of the central λ-layer has a greater electronic bandgap compared to the cavity resonance frequency and the frequency of the pump. This observation is caused by the fact that pumping with photon energies near the bandgap resonantly enhances the switched magnitude. We thus find that cavities operating in the telecom O-band are more amenable to ultrafast Kerr switching than those operating at lower frequencies, such as the C-band. Our results indicate that the large bandgap of AlGaAs/AlAs cavity allows to tune both the pump and the probe to the telecom range to perform Kerr switching without detrimental two-photon absorption. We observe that the magnitude of the resonance frequency shift decreases with increasing quality factor of the cavity. Our model shows that the magnitude of the resonance frequency shift depends on the pump pulse duration and is maximized when the duration matches the cavity storage time to within a factor two. In our experiments, we obtain a maximum shift of the cavity resonance relative to the cavity linewidth of 20%. We project that the shift of the cavity resonance can be increased twofold with a pump pulse duration that better matches the cavity storage time. We provide the essential parameter settings for different materials so that the frequency shift of the cavity resonance can be maximized using the electronic Kerr effect.

  4. Statistical characteristics of storm interevent time, depth, and duration for eastern New Mexico, Oklahoma, and Texas

    USGS Publications Warehouse

    Asquith, William H.; Roussel, Meghan C.; Cleveland, Theodore G.; Fang, Xing; Thompson, David B.

    2006-01-01

    The design of small runoff-control structures, from simple floodwater-detention basins to sophisticated best-management practices, requires the statistical characterization of rainfall as a basis for cost-effective, risk-mitigated, hydrologic engineering design. The U.S. Geological Survey, in cooperation with the Texas Department of Transportation, has developed a framework to estimate storm statistics including storm interevent times, distributions of storm depths, and distributions of storm durations for eastern New Mexico, Oklahoma, and Texas. The analysis is based on hourly rainfall recorded by the National Weather Service. The database contains more than 155 million hourly values from 774 stations in the study area. Seven sets of maps depicting ranges of mean storm interevent time, mean storm depth, and mean storm duration, by county, as well as tables listing each of those statistics, by county, were developed. The mean storm interevent time is used in probabilistic models to assess the frequency distribution of storms. The Poisson distribution is suggested to model the distribution of storm occurrence, and the exponential distribution is suggested to model the distribution of storm interevent times. The four-parameter kappa distribution is judged as an appropriate distribution for modeling the distribution of both storm depth and storm duration. Preference for the kappa distribution is based on interpretation of L-moment diagrams. Parameter estimates for the kappa distributions are provided. Separate dimensionless frequency curves for storm depth and duration are defined for eastern New Mexico, Oklahoma, and Texas. Dimension is restored by multiplying curve ordinates by the mean storm depth or mean storm duration to produce quantile functions of storm depth and duration. Minimum interevent time and location have slight influence on the scale and shape of the dimensionless frequency curves. Ten example problems and solutions to possible applications are provided.

  5. The word frequency effect during sentence reading: A linear or nonlinear effect of log frequency?

    PubMed

    White, Sarah J; Drieghe, Denis; Liversedge, Simon P; Staub, Adrian

    2016-10-20

    The effect of word frequency on eye movement behaviour during reading has been reported in many experimental studies. However, the vast majority of these studies compared only two levels of word frequency (high and low). Here we assess whether the effect of log word frequency on eye movement measures is linear, in an experiment in which a critical target word in each sentence was at one of three approximately equally spaced log frequency levels. Separate analyses treated log frequency as a categorical or a continuous predictor. Both analyses showed only a linear effect of log frequency on the likelihood of skipping a word, and on first fixation duration. Ex-Gaussian analyses of first fixation duration showed similar effects on distributional parameters in comparing high- and medium-frequency words, and medium- and low-frequency words. Analyses of gaze duration and the probability of a refixation suggested a nonlinear pattern, with a larger effect at the lower end of the log frequency scale. However, the nonlinear effects were small, and Bayes Factor analyses favoured the simpler linear models for all measures. The possible roles of lexical and post-lexical factors in producing nonlinear effects of log word frequency during sentence reading are discussed.

  6. The optimal duration of frequency-volume charts related to compliance and reliability.

    PubMed

    van Haarst, Ernst P; Bosch, J L H Ruud

    2014-03-01

    To assess Frequency-volume charts (FVCs) for the yield of additional recorded days and the ideal duration of recording related to compliance and reliability. Of 500 consecutive urologic outpatients willing to complete a 7-day FVC, 378 FVCs were evaluable. During seven consecutive days every voiding time and volume were recorded. Missed entries were indicated with a coded letter, thereby assessing the true frequency and compliance. Reliability is the agreement of the day-to-day FVC parameters with the 7-day FVC pattern. Single-day reliability was assessed and used in the Spearman-Brown formula. FVCs of 228 male and 150 females were evaluated. Mean age was 55.2 years (standard deviation [SD]: 16.2 years), and mean 24-hr urine production was 1,856 ml (SD: 828 ml). The percentage of patients with complete FVCs decreased from 78% on day 2 to 58% on day 7, and dropped below 70% after 4 days. Single-day reliability was r = 0.63 for nocturnal urine production, r = 0.72 for 24-hr urine production, and r = 0.80 for mean voided volume. At 5 days, reliability of 90% was achieved for all parameters. With each additional day, FVCs showed a decrease in compliance and an increase in reliability. At day 3, reliability of 80% was achieved for all FVC parameters, but compliance dropped to 73%. Beyond 5 days, the yield of additional recorded days was limited. We advocate an FVC duration of 3 days, but the duration may be shortened or extended depending on the goal of the FVC. © 2013 Wiley Periodicals, Inc.

  7. On the consideration of scaling properties of extreme rainfall in Madrid (Spain) for developing a generalized intensity-duration-frequency equation and assessing probable maximum precipitation estimates

    NASA Astrophysics Data System (ADS)

    Casas-Castillo, M. Carmen; Rodríguez-Solà, Raúl; Navarro, Xavier; Russo, Beniamino; Lastra, Antonio; González, Paula; Redaño, Angel

    2018-01-01

    The fractal behavior of extreme rainfall intensities registered between 1940 and 2012 by the Retiro Observatory of Madrid (Spain) has been examined, and a simple scaling regime ranging from 25 min to 3 days of duration has been identified. Thus, an intensity-duration-frequency (IDF) master equation of the location has been constructed in terms of the simple scaling formulation. The scaling behavior of probable maximum precipitation (PMP) for durations between 5 min and 24 h has also been verified. For the statistical estimation of the PMP, an envelope curve of the frequency factor ( k m ) based on a total of 10,194 station-years of annual maximum rainfall from 258 stations in Spain has been developed. This curve could be useful to estimate suitable values of PMP at any point of the Iberian Peninsula from basic statistical parameters (mean and standard deviation) of its rainfall series. [Figure not available: see fulltext.

  8. Temporal selectivity by single neurons in the torus semicircularis of Batrachyla antartandica (Amphibia: Leptodactylidae).

    PubMed

    Penna, M; Lin, W Y; Feng, A S

    2001-12-01

    We investigated the response selectivities of single auditory neurons in the torus semicircularis of Batrachyla antartandica (a leptodactylid from southern Chile) to synthetic stimuli having diverse temporal structures. The advertisement call for this species is characterized by a long sequence of brief sound pulses having a dominant frequency of about 2000 Hz. We constructed five different series of synthetic stimuli in which the following acoustic parameters were systematically modified, one at a time: pulse rate, pulse duration, pulse rise time, pulse fall time, and train duration. The carrier frequency of these stimuli was fixed at the characteristic frequency of the units under study (n=44). Response patterns of TS units to these synthetic call variants revealed different degrees of selectivity for each of the temporal variables. A substantial number of neurons showed preference for pulse rates below 2 pulses s(-1), approximating the values found in natural advertisement calls. Tonic neurons generally showed preferences for long pulse durations, long rise and fall times, and long train durations. In contrast, phasic and phasic-burst neurons preferred stimuli with short duration, short rise and fall times and short train durations.

  9. A Proposed Change to ITU-R Recommendation 681

    NASA Technical Reports Server (NTRS)

    Davarian, F.

    1996-01-01

    Recommendation 681 of the International Telecommunications Union (ITU) provides five models for the prediction of propagation effects on land mobile satellite links: empirical roadside shadowing (ERS), attenuation frequency scaling, fade duration distribution, non-fade duration distribution, and fading due to multipath. Because the above prediction models have been empirically derived using a limited amount of data, these schemes work only for restricted ranges of link parameters. With the first two models, for example, the frequency and elevation angle parameters are restricted to 0.8 to 2.7 GHz and 20 to 60 degrees, respectively. Recently measured data have enabled us to enhance the range of the first two schemes. Moreover, for convenience, they have been combined into a single scheme named the extended empirical roadside shadowing (EERS) model.

  10. Female harbor seal (Phoca vitulina) behavioral response to playbacks of underwater male acoustic advertisement displays

    PubMed Central

    Blades, Brittany; Parks, Susan E.

    2018-01-01

    During the breeding season, male harbor seals (Phoca vitulina) make underwater acoustic displays using vocalizations known as roars. These roars have been shown to function in territory establishment in some breeding areas and have been hypothesized to be important for female choice, but the function of these sounds remains unresolved. This study consisted of a series of playback experiments in which captive female harbor seals were exposed to recordings of male roars to determine if females respond to recordings of male vocalizations and whether or not they respond differently to roars from categories with different acoustic characteristics. The categories included roars with characteristics of dominant males (longest duration, lowest frequency), subordinate males (shortest duration, highest frequency), combinations of call parameters from dominant and subordinate males (long duration, high frequency and short duration, low frequency), and control playbacks of water noise and water noise with tonal signals in the same frequency range as male signals. Results indicate that overall females have a significantly higher level of response to playbacks that imitate male vocalizations when compared to control playbacks of water noise. Specifically, there was a higher level of response to playbacks representing dominant male vocalization when compared to the control playbacks. For most individuals, there was a greater response to playbacks representing dominant male vocalizations compared to playbacks representing subordinate male vocalizations; however, there was no statistical difference between those two playback types. Additionally, there was no difference between the playbacks of call parameter combinations and the controls. Investigating female preference for male harbor seal vocalizations is a critical step in understanding the harbor seal mating system and further studies expanding on this captive study will help shed light on this important issue. PMID:29607261

  11. Female harbor seal (Phoca vitulina) behavioral response to playbacks of underwater male acoustic advertisement displays.

    PubMed

    Matthews, Leanna P; Blades, Brittany; Parks, Susan E

    2018-01-01

    During the breeding season, male harbor seals ( Phoca vitulina ) make underwater acoustic displays using vocalizations known as roars. These roars have been shown to function in territory establishment in some breeding areas and have been hypothesized to be important for female choice, but the function of these sounds remains unresolved. This study consisted of a series of playback experiments in which captive female harbor seals were exposed to recordings of male roars to determine if females respond to recordings of male vocalizations and whether or not they respond differently to roars from categories with different acoustic characteristics. The categories included roars with characteristics of dominant males (longest duration, lowest frequency), subordinate males (shortest duration, highest frequency), combinations of call parameters from dominant and subordinate males (long duration, high frequency and short duration, low frequency), and control playbacks of water noise and water noise with tonal signals in the same frequency range as male signals. Results indicate that overall females have a significantly higher level of response to playbacks that imitate male vocalizations when compared to control playbacks of water noise. Specifically, there was a higher level of response to playbacks representing dominant male vocalization when compared to the control playbacks. For most individuals, there was a greater response to playbacks representing dominant male vocalizations compared to playbacks representing subordinate male vocalizations; however, there was no statistical difference between those two playback types. Additionally, there was no difference between the playbacks of call parameter combinations and the controls. Investigating female preference for male harbor seal vocalizations is a critical step in understanding the harbor seal mating system and further studies expanding on this captive study will help shed light on this important issue.

  12. Assessing and ranking the flammability of some ornamental plant species to select firewise plants for landscaping in WUI (SE France).

    NASA Astrophysics Data System (ADS)

    Ganteaume, A.; Jappiot, M.; Lampin, C.

    2012-04-01

    The increasing urbanization of Wildland-Urban Interfaces (WUI) as well as the high fire occurrence in these areas requires the assessment and the ranking of the flammability of the ornamental vegetation surrounding houses especially that planted in hedges. Thus, the flammability of seven species, among those most frequently planted in hedges in Provence (South-Eastern France), were studied at particle level and at dead surface fuel level (litters) under laboratory conditions. The flammability parameters (ignition frequency, time-to-ignition, flaming duration) of the very fine particles (live leaves and particles <2 mm in diameter) were measured using an epiradiator as burning device. The flammability parameters (ignition frequency, time-to-ignition, flaming duration and initial flame propagation) of the undisturbed litter samples were recorded during burning experiments performed on fire bench. Burning experiments using the epiradiator showed that live leaves of Phyllostachys sp., Photinia frasei and Prunus laurocerasus had the shortest time-to-ignition and the highest ignition frequency and flaming duration whereas Pittosporum tobira and Nerium oleander were the longest to ignite with a low frequency. Phyllostachys sp. and Nerium oleander litters were the shortest to ignite while Prunus laurocerasus litter had the lowest bulk density and long time-to-ignition, but high flame propagation. Photinia fraseri litter ignited frequently and had a high flame spread while Pittosporum tobira litter ignited the least frequently and for the shortest duration. Cupressus sempervirens litter had the highest bulk density and the longest flaming duration but the lowest flame propagation. Pyracantha coccinea litter was the longest to ignite and flame propagation was low but lasted a long time. Hierarchical cluster analysis performed on the flammability parameters of live leaves and of litters ranked the seven species in four distinct clusters from the most flammable (Prunus laurocerasus and Pyracantha coccinea) to the least flammable (Pittosporum tobira and Nerium oleander); the other species displaying two groups of intermediate flammabilities (Phyllostachys sp.- Photinia fraseri and Cupressus sempervirens ). The species with highly flammable characteristics should not be used in hedges planted in WUIs in South-Eastern France.

  13. A comparative study of primary and secondary stereotypies.

    PubMed

    Ghosh, Debabrata; Rajan, Prashant V; Erenberg, Gerald

    2013-12-01

    This study compares primary stereotypies (repetitive, self-stimulating, and seemingly nonsensical movements that can occur within typically developing children) and secondary stereotypies (those occurring within autistic or mentally retarded children). Utilizing a retrospective chart review from 1995 to 2010, the current study compares primary and secondary stereotypies by the application of a classification system that organizes the movement by its type (motor only, phonic only, mixed) and complexity. In addition, it investigates other parameters associated with the movements such as duration, frequency, age, functional impairment, and progression. The sample group consisted of 28 primary and 28 secondary cases. Primary stereotypies were predominantly motor, simple, of shorter duration, and of less frequency, whereas secondary stereotypies had more vocalization, complexity, longer durations, and higher frequencies. Moreover, functional impairment due to stereotypies was noted in 3 primary and 7 secondary cases, and worsening of stereotypies was noted in 70% of primary versus 44% of secondary cases.

  14. An investigation of fatigue phenomenon in the upper limb muscle due to short duration pulses in an FES system

    NASA Astrophysics Data System (ADS)

    Naeem, Jannatul; Wong Azman, Amelia; Khan, Sheroz; Mohd Mustafah, Yasir

    2013-12-01

    Functional Electrical Stimulation (FES) is a method of artificially stimulating muscles or nerves in order to result in contraction or relaxation of muscles. Many studies have shown that FES system has helped patients to live a better lives especially those who are suffering from physical mobility. Unfortunately, one of the main limitations of an FES system besides of its high cost is largely due to muscle fatigue. Muscle fatigue will affect the training duration which could delay patients' recovery rate. In this paper, we analyzed the occurrence of this fatigue phenomenon in terms of stimulator parameters such as amplitude, frequency, pulse width and pulse shape. The objective of this investigation is to identify other key features of the FES system parameters in order to prolong the training duration among patients. The experiment has been done on a healthy person for the duration of one minute and later the muscles response will be observed. Resultant muscle response is recorded as force using force resistive sensor. The experimental results show muscles will get fatigue at a different rate as the frequency increases. The experiment also shows that the duty cycle is reciprocal to the resultant force.

  15. Factors affecting reorganisation of memory encoding networks in temporal lobe epilepsy

    PubMed Central

    Sidhu, M.K.; Stretton, J.; Winston, G.P.; Symms, M.; Thompson, P.J.; Koepp, M.J.; Duncan, J.S.

    2015-01-01

    Summary Aims In temporal lobe epilepsy (TLE) due to hippocampal sclerosis reorganisation in the memory encoding network has been consistently described. Distinct areas of reorganisation have been shown to be efficient when associated with successful subsequent memory formation or inefficient when not associated with successful subsequent memory. We investigated the effect of clinical parameters that modulate memory functions: age at onset of epilepsy, epilepsy duration and seizure frequency in a large cohort of patients. Methods We studied 53 patients with unilateral TLE and hippocampal sclerosis (29 left). All participants performed a functional magnetic resonance imaging memory encoding paradigm of faces and words. A continuous regression analysis was used to investigate the effects of age at onset of epilepsy, epilepsy duration and seizure frequency on the activation patterns in the memory encoding network. Results Earlier age at onset of epilepsy was associated with left posterior hippocampus activations that were involved in successful subsequent memory formation in left hippocampal sclerosis patients. No association of age at onset of epilepsy was seen with face encoding in right hippocampal sclerosis patients. In both left hippocampal sclerosis patients during word encoding and right hippocampal sclerosis patients during face encoding, shorter duration of epilepsy and lower seizure frequency were associated with medial temporal lobe activations that were involved in successful memory formation. Longer epilepsy duration and higher seizure frequency were associated with contralateral extra-temporal activations that were not associated with successful memory formation. Conclusion Age at onset of epilepsy influenced verbal memory encoding in patients with TLE due to hippocampal sclerosis in the speech-dominant hemisphere. Shorter duration of epilepsy and lower seizure frequency were associated with less disruption of the efficient memory encoding network whilst longer duration and higher seizure frequency were associated with greater, inefficient, extra-temporal reorganisation. PMID:25616449

  16. Effective intracortical microstimulation parameters applied to primary motor cortex for evoking forelimb movements to stable spatial end points

    PubMed Central

    Van Acker, Gustaf M.; Amundsen, Sommer L.; Messamore, William G.; Zhang, Hongyu Y.; Luchies, Carl W.; Kovac, Anthony

    2013-01-01

    High-frequency, long-duration intracortical microstimulation (HFLD-ICMS) applied to motor cortex is recognized as a useful and informative method for corticomotor mapping by evoking natural-appearing movements of the limb to consistent stable end-point positions. An important feature of these movements is that stimulation of a specific site in motor cortex evokes movement to the same spatial end point regardless of the starting position of the limb. The goal of this study was to delineate effective stimulus parameters for evoking forelimb movements to stable spatial end points from HFLD-ICMS applied to primary motor cortex (M1) in awake monkeys. We investigated stimulation of M1 as combinations of frequency (30–400 Hz), amplitude (30–200 μA), and duration (0.5–2 s) while concurrently recording electromyographic (EMG) activity from 24 forelimb muscles and movement kinematics with a motion capture system. Our results suggest a range of parameters (80–140 Hz, 80–140 μA, and 1,000-ms train duration) that are effective and safe for evoking forelimb translocation with subsequent stabilization at a spatial end point. The mean time for stimulation to elicit successful movement of the forelimb to a stable spatial end point was 475.8 ± 170.9 ms. Median successful frequency and amplitude were 110 Hz and 110 μA, respectively. Attenuated parameters resulted in inconsistent, truncated, or undetectable movements, while intensified parameters yielded no change to movement end points and increased potential for large-scale physiological spread and adverse focal motor effects. Establishing cortical stimulation parameters yielding consistent forelimb movements to stable spatial end points forms the basis for a systematic and comprehensive mapping of M1 in terms of evoked movements and associated muscle synergies. Additionally, the results increase our understanding of how the central nervous system may encode movement. PMID:23741044

  17. Evaluation of Bayesian estimation of a hidden continuous-time Markov chain model with application to threshold violation in water-quality indicators

    USGS Publications Warehouse

    Deviney, Frank A.; Rice, Karen; Brown, Donald E.

    2012-01-01

    Natural resource managers require information concerning  the frequency, duration, and long-term probability of occurrence of water-quality indicator (WQI) violations of defined thresholds. The timing of these threshold crossings often is hidden from the observer, who is restricted to relatively infrequent observations. Here, a model for the hidden process is linked with a model for the observations, and the parameters describing duration, return period, and long-term probability of occurrence are estimated using Bayesian methods. A simulation experiment is performed to evaluate the approach under scenarios based on the equivalent of a total monitoring period of 5-30 years and an observation frequency of 1-50 observations per year. Given constant threshold crossing rate, accuracy and precision of parameter estimates increased with longer total monitoring period and more-frequent observations. Given fixed monitoring period and observation frequency, accuracy and precision of parameter estimates increased with longer times between threshold crossings. For most cases where the long-term probability of being in violation is greater than 0.10, it was determined that at least 600 observations are needed to achieve precise estimates.  An application of the approach is presented using 22 years of quasi-weekly observations of acid-neutralizing capacity from Deep Run, a stream in Shenandoah National Park, Virginia. The time series also was sub-sampled to simulate monthly and semi-monthly sampling protocols. Estimates of the long-term probability of violation were unbiased despite sampling frequency; however, the expected duration and return period were over-estimated using the sub-sampled time series with respect to the full quasi-weekly time series.

  18. The Source Parameters of Echolocation Clicks from Captive and Free-Ranging Yangtze Finless Porpoises (Neophocaena asiaeorientalis asiaeorientalis).

    PubMed

    Fang, Liang; Wang, Ding; Li, Yongtao; Cheng, Zhaolong; Pine, Matthew K; Wang, Kexiong; Li, Songhai

    2015-01-01

    The clicks of Yangtze finless porpoises (Neophocaena asiaeorientalis asiaeorientalis) from 7 individuals in the tank of Baiji aquarium, 2 individuals in a netted pen at Shishou Tian-e-zhou Reserve and 4 free-ranging individuals at Tianxingzhou were recorded using a broadband digital recording system with four element hydrophones. The peak-to-peak apparent source level (ASL_pp) of clicks from individuals at the Baiji aquarium was 167 dB re 1 μPa with mean center frequency of 133 kHz, -3dB bandwidth of 18 kHz and -10 dB duration of 58 μs. The ASL_pp of clicks from individuals at the Shishou Tian-e-zhou Reserve was 180 dB re 1 μPa with mean center frequency of 128 kHz, -3dB bandwidth of 20 kHz and -10 dB duration of 39 μs. The ASL_pp of clicks from individuals at Tianxingzhou was 176 dB re 1 μPa with mean center frequency of 129 kHz, -3dB bandwidth of 15 kHz and -10 dB duration of 48 μs. Differences between the source parameters of clicks among the three groups of finless porpoises suggest these animals adapt to their echolocation signals depending on their surroundings.

  19. Interaction between anxiety, depression, quality of life and clinical parameters in chronic tension-type headache.

    PubMed

    Peñacoba-Puente, Cecilia; Fernández-de-Las-Peñas, César; González-Gutierrez, Jose L; Miangolarra-Page, Juan C; Pareja, Juan A

    2008-10-01

    Our aim was to investigate the mediating or moderating role of anxiety and depression in the relationship between headache clinical parameters and quality of life in Chronic Tension-Type Headache (CTTH). Twenty-five patients diagnosed with CTTH according to the criteria of the International Headache Society were studied. A headache diary was kept for 4 weeks in order to substantiate the diagnosis and record the pain history. Quality of life was assessed by means of the Medical Outcome Study (MOS) 36-Item Short-Form (SF-36) questionnaire. The Beck Depression Inventory (BDI-II) was used to assess depression, and the Trait Anxiety Scale (TA) from the State-Trait Anxiety Inventory was administered in order to assess anxiety. Moderating and mediating analyses were conducted with ordinary least squares multiple regression analysis using the SPSS General Linear Model procedure. Anxiety mediated the effect between headache frequency and quality of life, but not the effect of either headache intensity or duration. Anxiety totally mediated the effects of headache frequency on vitality, social functioning and mental health. On the other hand, depression modulated the effect in the mental health domain. The effect in the mental health domain was a function of the interaction between headache duration and depression (beta=-0.34, p<0.05), after controlling for age, gender, the main effects of headache duration, and depression. We did not find anxiety to be a moderating factor between intensity, frequency or duration of headache and perceived quality of life. Anxiety exerts a mediating effect, conditioning the relationship between headache frequency and some quality of life domains; depression seems to play an inherent role in the reduced quality of life of these patients, that is, it has a moderating effect.

  20. Precipitation extremes on multiple timescales - Bartlett-Lewis rectangular pulse model and intensity-duration-frequency curves

    NASA Astrophysics Data System (ADS)

    Ritschel, Christoph; Ulbrich, Uwe; Névir, Peter; Rust, Henning W.

    2017-12-01

    For several hydrological modelling tasks, precipitation time series with a high (i.e. sub-daily) resolution are indispensable. The data are, however, not always available, and thus model simulations are used to compensate. A canonical class of stochastic models for sub-daily precipitation are Poisson cluster processes, with the original Bartlett-Lewis (OBL) model as a prominent representative. The OBL model has been shown to well reproduce certain characteristics found in observations. Our focus is on intensity-duration-frequency (IDF) relationships, which are of particular interest in risk assessment. Based on a high-resolution precipitation time series (5 min) from Berlin-Dahlem, OBL model parameters are estimated and IDF curves are obtained on the one hand directly from the observations and on the other hand from OBL model simulations. Comparing the resulting IDF curves suggests that the OBL model is able to reproduce the main features of IDF statistics across several durations but cannot capture rare events (here an event with a return period larger than 1000 years on the hourly timescale). In this paper, IDF curves are estimated based on a parametric model for the duration dependence of the scale parameter in the generalized extreme value distribution; this allows us to obtain a consistent set of curves over all durations. We use the OBL model to investigate the validity of this approach based on simulated long time series.

  1. Continuous rainfall simulation for regional flood risk assessment - application in the Austrian Alps

    NASA Astrophysics Data System (ADS)

    Salinas, Jose Luis; Nester, Thomas; Komma, Jürgen; Blöschl, Günter

    2017-04-01

    Generation of realistic synthetic spatial rainfall is of pivotal importance for assessing regional hydroclimatic hazard as the input for long term rainfall-runoff simulations. The correct reproduction of the observed rainfall characteristics, such as regional intensity-duration-frequency curves, is necessary to adequately model the magnitude and frequency of the flood peaks. Furthermore, the replication of the observed rainfall spatial and temporal correlations allows to model important other hydrological features like antecedent soil moisture conditions before extreme rainfall events. In this work, we present an application in the Tirol region (Austrian alps) of a modification of the model presented by Bardossy and Platte (1992), where precipitation is modeled on a station basis as a mutivariate autoregressive model (mAr) in a Normal space, and then transformed to a Gamma-distributed space. For the sake of simplicity, the parameters of the Gamma distributions are assumed to vary monthly according to a sinusoidal function, and are calibrated trying to simultaneously reproduce i) mean annual rainfall, ii) mean daily rainfall amounts, iii) standard deviations of daily rainfall amounts, and iv) 24-hours intensity duration frequency curve. The calibration of the spatial and temporal correlation parameters is performed in a way that the intensity-duration-frequency curves aggregated at different spatial and temporal scales reproduce the measured ones. Bardossy, A., and E. J. Plate (1992), Space-time model for daily rainfall using atmospheric circulation patterns, Water Resour. Res., 28(5), 1247-1259, doi:10.1029/91WR02589.

  2. Optimization of Pulsed-DEER Measurements for Gd-Based Labels: Choice of Operational Frequencies, Pulse Durations and Positions, and Temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raitsimring, A.; Astashkin, A. V.; Enemark, J. H.

    2012-12-29

    In this work, the experimental conditions and parameters necessary to optimize the long-distance (≥ 60 Å) Double Electron-Electron Resonance (DEER) measurements of biomacromolecules labeled with Gd(III) tags are analyzed. The specific parameters discussed are the temperature, microwave band, the separation between the pumping and observation frequencies, pulse train repetition rate, pulse durations and pulse positioning in the electron paramagnetic resonance spectrum. It was found that: (i) in optimized DEER measurements, the observation pulses have to be applied at the maximum of the EPR spectrum; (ii) the optimal temperature range for Ka-band measurements is 14-17 K, while in W-band the optimalmore » temperatures are between 6-9 K; (iii) W-band is preferable to Ka-band for DEER measurements. Recent achievements and the conditions necessary for short-distance measurements (<15 Å) are also briefly discussed.« less

  3. Synchrony in Joint Action Is Directed by Each Participant’s Motor Control System

    PubMed Central

    Noy, Lior; Weiser, Netta; Friedman, Jason

    2017-01-01

    In this work, we ask how the probability of achieving synchrony in joint action is affected by the choice of motion parameters of each individual. We use the mirror game paradigm to study how changes in leader’s motion parameters, specifically frequency and peak velocity, affect the probability of entering the state of co-confidence (CC) motion: a dyadic state of synchronized, smooth and co-predictive motions. In order to systematically study this question, we used a one-person version of the mirror game, where the participant mirrored piece-wise rhythmic movements produced by a computer on a graphics tablet. We systematically varied the frequency and peak velocity of the movements to determine how these parameters affect the likelihood of synchronized joint action. To assess synchrony in the mirror game we used the previously developed marker of co-confident (CC) motions: smooth, jitter-less and synchronized motions indicative of co-predicative control. We found that when mirroring movements with low frequencies (i.e., long duration movements), the participants never showed CC, and as the frequency of the stimuli increased, the probability of observing CC also increased. This finding is discussed in the framework of motor control studies showing an upper limit on the duration of smooth motion. We confirmed the relationship between motion parameters and the probability to perform CC with three sets of data of open-ended two-player mirror games. These findings demonstrate that when performing movements together, there are optimal movement frequencies to use in order to maximize the possibility of entering a state of synchronized joint action. It also shows that the ability to perform synchronized joint action is constrained by the properties of our motor control systems. PMID:28443047

  4. Variations of seismic parameters during different activity levels of the Soufriere Hills Volcano, Montserrat

    NASA Astrophysics Data System (ADS)

    Powell, T.; Neuberg, J.

    2003-04-01

    The low-frequency seismic events on Montserrat are linked to conduit resonance and the pressurisation of the volcanic system. Analysis of these events tell us more about the behaviour of the volcanic system and provide a monitoring and interpretation tool. We have written an Automated Event Classification Algorithm Program (AECAP), which finds and classifies seismic events and calculates seismic parameters such as energy, intermittency, peak frequency and event duration. Comparison of low-frequency energy with the tilt cycles in 1997 allows us to link pressurisation of the volcano with seismic behaviour. An empirical relationship provides us with an estimate of pressurisation through released seismic energy. During 1997, the activity of the volcano varied considerably. We compare seismic parameters from quiet periods to those from active periods and investigate how the relationships between these parameters change. These changes are then used to constrain models of magmatic processes during different stages of volcanic activity.

  5. Spike shape analysis of electromyography for parkinsonian tremor evaluation.

    PubMed

    Marusiak, Jarosław; Andrzejewska, Renata; Świercz, Dominika; Kisiel-Sajewicz, Katarzyna; Jaskólska, Anna; Jaskólski, Artur

    2015-12-01

    Standard electromyography (EMG) parameters have limited utility for evaluation of Parkinson disease (PD) tremor. Spike shape analysis (SSA) EMG parameters are more sensitive than standard EMG parameters for studying motor control mechanisms in healthy subjects. SSA of EMG has not been used to assess parkinsonian tremor. This study assessed the utility of SSA and standard time and frequency analysis for electromyographic evaluation of PD-related resting tremor. We analyzed 1-s periods of EMG recordings to detect nontremor and tremor signals in relaxed biceps brachii muscle of seven mild to moderate PD patients. SSA revealed higher mean spike amplitude, duration, and slope and lower mean spike frequency in tremor signals than in nontremor signals. Standard EMG parameters (root mean square, median, and mean frequency) did not show differences between the tremor and nontremor signals. SSA of EMG data is a sensitive method for parkinsonian tremor evaluation. © 2015 Wiley Periodicals, Inc.

  6. Effects of pulse duration on magnetostimulation thresholds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saritas, Emine U., E-mail: saritas@ee.bilkent.edu.tr; Department of Electrical and Electronics Engineering, Bilkent University, Bilkent, Ankara 06800; National Magnetic Resonance Research Center

    Purpose: Medical imaging techniques such as magnetic resonance imaging and magnetic particle imaging (MPI) utilize time-varying magnetic fields that are subject to magnetostimulation limits, which often limit the speed of the imaging process. Various human-subject experiments have studied the amplitude and frequency dependence of these thresholds for gradient or homogeneous magnetic fields. Another contributing factor was shown to be number of cycles in a magnetic pulse, where the thresholds decreased with longer pulses. The latter result was demonstrated on two subjects only, at a single frequency of 1.27 kHz. Hence, whether the observed effect was due to the number ofmore » cycles or due to the pulse duration was not specified. In addition, a gradient-type field was utilized; hence, whether the same phenomenon applies to homogeneous magnetic fields remained unknown. Here, the authors investigate the pulse duration dependence of magnetostimulation limits for a 20-fold range of frequencies using homogeneous magnetic fields, such as the ones used for the drive field in MPI. Methods: Magnetostimulation thresholds were measured in the arms of six healthy subjects (age: 27 ± 5 yr). Each experiment comprised testing the thresholds at eight different pulse durations between 2 and 125 ms at a single frequency, which took approximately 30–40 min/subject. A total of 34 experiments were performed at three different frequencies: 1.2, 5.7, and 25.5 kHz. A solenoid coil providing homogeneous magnetic field was used to induce stimulation, and the field amplitude was measured in real time. A pre-emphasis based pulse shaping method was employed to accurately control the pulse durations. Subjects reported stimulation via a mouse click whenever they felt a twitching/tingling sensation. A sigmoid function was fitted to the subject responses to find the threshold at a specific frequency and duration, and the whole procedure was repeated at all relevant frequencies and pulse durations. Results: The magnetostimulation limits decreased with increasing pulse duration (T{sub pulse}). For T{sub pulse} < 18 ms, the thresholds were significantly higher than at the longest pulse durations (p < 0.01, paired Wilcoxon signed-rank test). The normalized magnetostimulation threshold (B{sub Norm}) vs duration curve at all three frequencies agreed almost identically, indicating that the observed effect is independent of the operating frequency. At the shortest pulse duration (T{sub pulse} ≈ 2 ms), the thresholds were approximately 24% higher than at the asymptotes. The thresholds decreased to within 4% of their asymptotic values for T{sub pulse} > 20 ms. These trends were well characterized (R{sup 2} = 0.78) by a stretched exponential function given by B{sub Norm}=1+αe{sup −(T{sub p}{sub u}{sub l}{sub s}{sub e}/β){sup γ}}, where the fitted parameters were α = 0.44, β = 4.32, and γ = 0.60. Conclusions: This work shows for the first time that the magnetostimulation thresholds decrease with increasing pulse duration, and that this effect is independent of the operating frequency. Normalized threshold vs duration trends are almost identical for a 20-fold range of frequencies: the thresholds are significantly higher at short pulse durations and settle to within 4% of their asymptotic values for durations longer than 20 ms. These results emphasize the importance of matching the human-subject experiments to the imaging conditions of a particular setup. Knowing the dependence of the safety limits to all contributing factors is critical for increasing the time-efficiency of imaging systems that utilize time-varying magnetic fields.« less

  7. Relationships of leisure-time and non-leisure-time physical activity with depressive symptoms: a population-based study of Taiwanese older adults.

    PubMed

    Chen, Li-Jung; Stevinson, Clare; Ku, Po-Wen; Chang, Yu-Kai; Chu, Da-Chen

    2012-03-14

    Limited research has explored the relationship between non-leisure-time physical activity (NLTPA), including domestic and work-related physical activities, with depressive symptoms. This study was designed to elucidate independent associations between leisure-time physical activity (LTPA), NLTPA, and specific parameters of physical activity (frequency, duration and intensity) with depressive symptoms in older adults. A total of 2,727 persons aged ≥ 65 years participating in the 2005 Taiwan National Health Interview Survey were studied. Depressive symptoms were measured by the Center for Epidemiological Studies Depression Scale. Information regarding energy parameters for each type of LTPA and NLTPA during the past 2-week period was analyzed. After adjusting for socio-demographic variables, lifestyle behaviors and health status, multivariate logistic regression models were used to compute adjusted odds ratios (AOR) for LTPA and NLTPA for predicting depressive symptoms. LTPA but not NLTPA was significantly associated with depressive symptoms. Compared with participants expending 2000+ kcal/week through LTPA, the risk of experiencing depressive symptoms was significantly higher for those expending 1-999 kcal/week (AOR = 2.06, 95% CI: 1.25-3.39), and those who expending 0 kcal/week (AOR = 3.72, 95%CI: 2.28-6.06). Among the three parameters of LTPA (intensity, duration and frequency) examined, only intensity was independently associated with depressive symptoms. These findings imply that exercise recommendations for older adults should emphasize the importance of higher intensity activity, rather than frequency or duration, for improved mental well-being. However, well-designed prospective cohort studies or intervention trials are needed to confirm these findings.

  8. Revisions to some parameters used in stochastic-method simulations of ground motion

    USGS Publications Warehouse

    Boore, David; Thompson, Eric M.

    2015-01-01

    The stochastic method of ground‐motion simulation specifies the amplitude spectrum as a function of magnitude (M) and distance (R). The manner in which the amplitude spectrum varies with M and R depends on physical‐based parameters that are often constrained by recorded motions for a particular region (e.g., stress parameter, geometrical spreading, quality factor, and crustal amplifications), which we refer to as the seismological model. The remaining ingredient for the stochastic method is the ground‐motion duration. Although the duration obviously affects the character of the ground motion in the time domain, it also significantly affects the response of a single‐degree‐of‐freedom oscillator. Recently published updates to the stochastic method include a new generalized double‐corner‐frequency source model, a new finite‐fault correction, a new parameterization of duration, and a new duration model for active crustal regions. In this article, we augment these updates with a new crustal amplification model and a new duration model for stable continental regions. Random‐vibration theory (RVT) provides a computationally efficient method to compute the peak oscillator response directly from the ground‐motion amplitude spectrum and duration. Because the correction factor used to account for the nonstationarity of the ground motion depends on the ground‐motion amplitude spectrum and duration, we also present new RVT correction factors for both active and stable regions.

  9. Period for Normalization of Voice Acoustic Parameters in Indian Pediatric Cochlear Implantees.

    PubMed

    Joy, Jeena V; Deshpande, Shweta; Vaid, Dr Neelam

    2017-05-01

    The purpose of this study was to investigate the duration required by children with cochlear implants to approximate the norms of voice acoustic parameters. The study design is retrospective. Thirty children with cochlear implants (chronological ages ranging between 4.1 and 6.7 years) were divided into three groups, based on the postimplantation duration. Ten normal-hearing children (chronological ages ranging between 4 and 7 years) were selected as the control group. All implanted children underwent an objective voice analysis using Dr. Speech software (Tiger DRS, Inc., Seattle, WA, USA) at 6 months and at 1 and 2 years of implant use. Voice analysis was done for the children in the control group and means were derived for all the parameters analyzed to obtain the normal values. Habitual fundamental frequency (HFF), jitter (frequency variation), and shimmer (amplitude variation) were the voice acoustic parameters analyzed for the vowels |a|, |i|, and |u|. The obtained values of these parameters were then compared with the norms. HFF for the children with implant use for 6 months and 1 year did significantly differ from the control group. However, there was no significant difference (P > 0.5) observed in the children with implant use for 2 years, thus matching the norms. Jitter and shimmer showed a significant difference (P < 0.5) even at 2 years of implant use when compared with the control group. The findings of the study divulge that children with cochlear implants approximate age-matched normal-hearing kids with respect to the voice acoustic parameter of HFF by 2 years of implant use. However, jitter and shimmer were not found to stabilize for the duration studied. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  10. Matching initial torque with different stimulation parameters influences skeletal muscle fatigue.

    PubMed

    Bickel, C Scott; Gregory, Chris M; Azuero, Andres

    2012-01-01

    A fundamental barrier to using electrical stimulation in the clinical setting is an inability to maintain torque production secondary to muscle fatigue. Electrical stimulation parameters are manipulated to influence muscle torque production, and they may also influence fatigability during repetitive stimulation. Our purpose was to determine the response of the quadriceps femoris to three different fatigue protocols using the same initial torque obtained by altering stimulator parameter settings. Participants underwent fatigue protocols in which either pulse frequency (lowHz), pulse duration (lowPD), or voltage (lowV) was manipulated to obtain an initial torque that equaled 25% of maximum voluntary isometric contraction. Muscle soreness was reported on a visual analog scale 48 h after each fatigue test. The lowHz protocol resulted in the least fatigue (25% +/- 14%); the lowPD (50% +/- 13%) and lowV (48% +/- 14%) protocols had similar levels of fatigue. The lowHz protocol resulted in significantly less muscle soreness than the higher frequency protocols. Stimulation protocols that use a lower frequency coupled with long pulse durations and high voltages result in lesser amounts of muscle fatigue and perceived soreness. The identification of optimal stimulation patterns to maximize muscle performance will reduce the effect of muscle fatigue and potentially improve clinical efficacy.

  11. Effects of flow rate and gas mixture on the welfare of weaned and neonate pigs during gas euthanasia.

    PubMed

    Sadler, L J; Hagen, C D; Wang, C; Widowski, T M; Johnson, A K; Millman, S T

    2014-02-01

    The objectives of this study were to assess efficacy and welfare implications of gas euthanasia when applied to weaned and neonate pigs. Parameters associated with welfare, which were measured before loss of consciousness, included open-mouth breathing, ataxia, righting response, and escape attempts. Two age groups (weaned and neonate) were assessed in 9 gas treatments arranged in a 2 × 4 factorial design, with 2 gas types (CO2 = 100% CO2 and 50:50 = 50:50 CO2:argon) and 4 flow rates (box volume exchange/min: slow = 20%; medium = 35%; fast = 50%; prefill = prefilled followed by 20%) and a control treatment in which ambient air was passed through the box. Pig pairs (10/treatment) were placed in a modified Euthanex AgPro system (Euthanex Corp., Palmer, PA). Behavioral and physiological responses were observed directly and from video recordings for latency, duration, prevalence (percent of pigs affected), and frequency (number of occurrences/pig). Data were analyzed as linear mixed models or with a Cox proportional hazard model as appropriate. Piglet pair was the experimental unit. For the weaned pig, welfare was superior with CO2 relative to 50:50 within 1 or more flow rates on the basis of reduced duration of open-mouth breathing, duration of ataxia, frequency of escape attempts, and duration and frequency of righting response (P < 0.05). No measured parameters indicated superior welfare with the use of 50:50, whereas latencies to loss of posture and last movement favored CO2 (P < 0.05). Faster flow rates were associated with reduced (P < 0.05) duration or frequency of open-mouth breathing, ataxia, and righting response, as well as superior (P < 0.05) indicators of efficacy, including latencies to loss of posture, gasping, and last movement, relative to slower flow rates. Weaned pigs were more likely to defecate (P < 0.01), display nasal discharge (P < 0.05), and display longer (P < 0.001) latencies to loss of posture and last movement than neonates. Duration of ataxia was the only parameter for which neonates were superior (P < 0.01) to weaned pigs during euthanasia. As such, a 50:50 CO2:argon gas mixture and slower flow rates should be avoided when euthanizing weaned or neonate pigs with gas methods. Neonate pigs succumb to the effects of gas euthanasia quicker than weaned pigs and display fewer signs of distress.

  12. ECCM Scheme against Interrupted Sampling Repeater Jammer Based on Parameter-Adjusted Waveform Design

    PubMed Central

    Wei, Zhenhua; Peng, Bo; Shen, Rui

    2018-01-01

    Interrupted sampling repeater jamming (ISRJ) is an effective way of deceiving coherent radar sensors, especially for linear frequency modulated (LFM) radar. In this paper, for a simplified scenario with a single jammer, we propose a dynamic electronic counter-counter measure (ECCM) scheme based on jammer parameter estimation and transmitted signal design. Firstly, the LFM waveform is transmitted to estimate the main jamming parameters by investigating the discontinuousness of the ISRJ’s time-frequency (TF) characteristics. Then, a parameter-adjusted intra-pulse frequency coded signal, whose ISRJ signal after matched filtering only forms a single false target, is designed adaptively according to the estimated parameters, i.e., sampling interval, sampling duration and repeater times. Ultimately, for typical jamming scenes with different jamming signal ratio (JSR) and duty cycle, we propose two particular ISRJ suppression approaches. Simulation results validate the effective performance of the proposed scheme for countering the ISRJ, and the trade-off relationship between the two approaches is demonstrated. PMID:29642508

  13. Top-down modulation of auditory processing: effects of sound context, musical expertise and attentional focus.

    PubMed

    Tervaniemi, M; Kruck, S; De Baene, W; Schröger, E; Alter, K; Friederici, A D

    2009-10-01

    By recording auditory electrical brain potentials, we investigated whether the basic sound parameters (frequency, duration and intensity) are differentially encoded among speech vs. music sounds by musicians and non-musicians during different attentional demands. To this end, a pseudoword and an instrumental sound of comparable frequency and duration were presented. The accuracy of neural discrimination was tested by manipulations of frequency, duration and intensity. Additionally, the subjects' attentional focus was manipulated by instructions to ignore the sounds while watching a silent movie or to attentively discriminate the different sounds. In both musicians and non-musicians, the pre-attentively evoked mismatch negativity (MMN) component was larger to slight changes in music than in speech sounds. The MMN was also larger to intensity changes in music sounds and to duration changes in speech sounds. During attentional listening, all subjects more readily discriminated changes among speech sounds than among music sounds as indexed by the N2b response strength. Furthermore, during attentional listening, musicians displayed larger MMN and N2b than non-musicians for both music and speech sounds. Taken together, the data indicate that the discriminative abilities in human audition differ between music and speech sounds as a function of the sound-change context and the subjective familiarity of the sound parameters. These findings provide clear evidence for top-down modulatory effects in audition. In other words, the processing of sounds is realized by a dynamically adapting network considering type of sound, expertise and attentional demands, rather than by a strictly modularly organized stimulus-driven system.

  14. Monitoring walking and cycling of middle-aged to older community dwellers using wireless wearable accelerometers.

    PubMed

    Zhang, Yuting; Beenakker, Karel G M; Butala, Pankil M; Lin, Cheng-Chieh; Little, Thomas D C; Maier, Andrea B; Stijntjes, Marjon; Vartanian, Richard; Wagenaar, Robert C

    2012-01-01

    Changes in gait parameters have been shown to be an important indicator of several age-related cognitive and physical declines of older adults. In this paper we propose a method to monitor and analyze walking and cycling activities based on a triaxial accelerometer worn on one ankle. We use an algorithm that can (1) distinguish between static and dynamic functional activities, (2) detect walking and cycling events, (3) identify gait parameters, including step frequency, number of steps, number of walking periods, and total walking duration per day, and (4) evaluate cycling parameters, including cycling frequency, number of cycling periods, and total cycling duration. Our algorithm is evaluated against the triaxial accelerometer data obtained from a group of 297 middle-aged to older adults wearing an activity monitor on the right ankle for approximately one week while performing unconstrained daily activities in the home and community setting. The correlation coefficients between each of detected gait and cycling parameters on two weekdays are all statistically significant, ranging from 0.668 to 0.873. These results demonstrate good test-retest reliability of our method in monitoring walking and cycling activities and analyzing gait and cycling parameters. This algorithm is efficient and causal in time and thus implementable for real-time monitoring and feedback.

  15. The Source Parameters of Echolocation Clicks from Captive and Free-Ranging Yangtze Finless Porpoises (Neophocaena asiaeorientalis asiaeorientalis)

    PubMed Central

    Fang, Liang; Wang, Ding; Li, Yongtao; Cheng, Zhaolong; Pine, Matthew K.; Wang, Kexiong; Li, Songhai

    2015-01-01

    The clicks of Yangtze finless porpoises (Neophocaena asiaeorientalis asiaeorientalis) from 7 individuals in the tank of Baiji aquarium, 2 individuals in a netted pen at Shishou Tian-e-zhou Reserve and 4 free-ranging individuals at Tianxingzhou were recorded using a broadband digital recording system with four element hydrophones. The peak-to-peak apparent source level (ASL_pp) of clicks from individuals at the Baiji aquarium was 167 dB re 1 μPa with mean center frequency of 133 kHz, -3dB bandwidth of 18 kHz and -10 dB duration of 58 μs. The ASL_pp of clicks from individuals at the Shishou Tian-e-zhou Reserve was 180 dB re 1 μPa with mean center frequency of 128 kHz, -3dB bandwidth of 20 kHz and -10 dB duration of 39 μs. The ASL_pp of clicks from individuals at Tianxingzhou was 176 dB re 1 μPa with mean center frequency of 129 kHz, -3dB bandwidth of 15 kHz and -10 dB duration of 48 μs. Differences between the source parameters of clicks among the three groups of finless porpoises suggest these animals adapt to their echolocation signals depending on their surroundings. PMID:26053758

  16. Killer whale (Orcinus orca) whistles from the western South Atlantic Ocean include high frequency signals.

    PubMed

    Andriolo, Artur; Reis, Sarah S; Amorim, Thiago O S; Sucunza, Federico; de Castro, Franciele R; Maia, Ygor Geyer; Zerbini, Alexandre N; Bortolotto, Guilherme A; Dalla Rosa, Luciano

    2015-09-01

    Acoustic parameters of killer whale (Orcinus orca) whistles were described for the western South Atlantic Ocean and highlight the occurrence of high frequency whistles. Killer whale signals were recorded on December of 2012, when a pod of four individuals was observed harassing a group of sperm whales. The high frequency whistles were highly stereotyped and were modulated mostly at ultrasonic frequencies. Compared to other contour types, the high frequency whistles are characterized by higher bandwidths, shorter durations, fewer harmonics, and higher sweep rates. The results add to the knowledge of vocal behavior of this species.

  17. Autonomic nervous system response patterns specificity to basic emotions.

    PubMed

    Collet, C; Vernet-Maury, E; Delhomme, G; Dittmar, A

    1997-01-12

    The aim of this study was to test the assumption that the autonomic nervous system responses to emotional stimuli are specific. A series of six slides was randomly presented to the subjects while six autonomic nervous system (ANS) parameters were recorded: skin conductance, skin potential, skin resistance, skin blood flow, skin temperature and instantaneous respiratory frequency. Each slide induced a basic emotion: happiness, surprise, anger, fear, sadness and disgust. Results have been first considered with reference to electrodermal responses (EDR) and secondly through thermo-vascular and respiratory variations. Classical as well as original indices were used to quantify autonomic responses. The six basic emotions were distinguished by Friedman variance analysis. Thus, ANS values corresponding to each emotion were compared two-by-two. EDR distinguished 13 emotion-pairs out of 15. 10 emotion-pairs were separated by skin resistance as well as skin conductance ohmic perturbation duration indices whereas conductance amplitude was only capable of distinguishing 7 emotion-pairs. Skin potential responses distinguished surprise and fear from sadness, and fear from disgust, according to their elementary pattern analysis in form and sign. Two-by-two comparisons of skin temperature, skin blood flow (estimated by the new non-oscillary duration index) and instantaneous respiratory frequency, enabled the distinction of 14 emotion-pairs out of 15. 9 emotion-pairs were distinguished by the non-oscillatory duration index values. Skin temperature was demonstrated to be different i.e. positive versus negative in response to anger and fear. The instantaneous respiratory frequency perturbation duration index was the only one capable of separating sadness from disgust. From the six ANS parameters study, different autonomic patterns were identified, each characterizing one of the six basic emotion used as inducing signals. No index alone, nor group of parameters (EDR and thermovascular for instance) were capable of distinguishing each emotion from another. However, electrodermal, thermo-vascular and respiratory responses taken as a whole, redundantly separated each emotion thus demonstrating the specificity of autonomic patterns.

  18. Frequency modulation and compression of optical pulses in an optical fibre with a travelling refractive-index wave

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zolotovskii, I O; Lapin, V A; Sementsov, D I

    2016-01-31

    We have studied the conditions for spectral broadening, frequency modulation and compression (both temporal and spectral) of Gaussian pulses propagating in a fibre with a travelling refractive-index wave. Analytical expressions have been derived for the dependences of pulse duration, chirp and spectral width on the distance travelled through the fibre, parameters of the fibre and radiation launched into it. Based on the numerical analysis we have studied the behaviour of these characteristics by changing the coefficient of the refractive-index modulation and other parameters of the travelling refractive-index wave. (nonlinear optical phenomena)

  19. Analysis of the Duration of Lower Band Rising Tone Chorus Elements Using Van Allen Probes Data

    NASA Astrophysics Data System (ADS)

    Teng, S.; Tao, X.

    2017-12-01

    The duration of lower band rising tone chorus elements is an important parameter to understand chorus excitation mechanism, and is analyzed statistically in this work using Van Allen Probes data. The distribution of chorus element duration (τ) as a function of magnetic local time, L shell, and geomagnetic activity level characterized by the AE index are presented. We show that the typical value of τ for the nightside (0.15s) is smaller than that for the dayside (0.25s), and τ increases with increasing L-shell and decreasing geomagnetic level. We also investigate the correlation between τ and the frequency sweep rate (Γ). The observed relation between the duration (τ) scales and the frequency sweep rate (Γ) is found to be as τ ∝ Γ(-0.9). Future work is needed to explain this relation theoretically. Our results should be helpful to the further development of the theoretical model of chorus excitation.

  20. The combination matters - distinct impact of lifestyle factors on sperm quality: a study on semen analysis of 1683 patients according to MSOME criteria

    PubMed Central

    2012-01-01

    Background Poor sperm quality can negatively affect embryonic development and IVF outcome. This study is aimed at investigating the influence of various lifestyle factors on semen quality according to MSOME (motile sperm organelle morphology examination) criteria. Methods 1683 male patients undergoing assisted reproductive technologies (ART) in our clinic were surveyed about their age, BMI (body mass index), ejaculation frequency, nutrition, sports, sleeping habits and social behavior. Semen samples were collected and evaluation of semen parameters according to MSOME and WHO criteria was performed. Results were grouped and statistically analyzed. Results Although single parameters had minor effects on sperm parameter, the combination of age, BMI, coffee intake, ejaculatory frequency and duration of sexual abstinence were identified as factors having a negative effect on sperm motility. Additionally, we could demonstrate that MSOME quality was reduced. The negative impact of age, BMI and coffee intake on sperm quality could be compensated if patients had a high ejaculation frequency and shorter periods of sexual abstinence. Conclusions Combinations of adverse lifestyle factors could have a detrimental impact on sperm, not only in terms of motility and sperm count but also in terms of sperm head vacuolization. This negative impact was shown to be compensated by higher ejaculation frequency and a shorter period of sexual abstinence. The compensation is most likely due to a shorter storage time in the male gonads, thus reducing the duration of sperms’ exposure to reactive oxygen species (ROS). PMID:23265183

  1. An acoustical study of English word stress produced by Americans and Koreans

    NASA Astrophysics Data System (ADS)

    Yang, Byunggon

    2002-05-01

    Acoustical correlates of stress can be divided into duration, intensity, and fundamental frequency. This study examined the acoustical difference in the first two syllables of stressed English words produced by ten American and Korean speakers. The Korean subjects scored very high in TOEFL. They read, at a normal speed, a fable from which the acoustical parameters of eight words were analyzed. In order to make the data comparison meaningful, each parameter was collected at 100 dynamic time points proportional to the total duration of the two syllables. Then, the ratio of the parameter sum of the first rime to that of the second rime was calculated to determine the relative prominence of the syllables. Results showed that the durations of the first two syllables were almost comparable between the Americans and Koreans. However, statistically significant differences showed up in the diphthong pronunciations and in the words with the second syllable stressed. Also, remarkably high r-squared values were found between pairs of the three acoustical parameters, which suggests that either one or a combination of two or more parameters may account for the prominence of a syllable within a word. [Work supported by Korea Science Foundation R01-1999-00229.

  2. Stimulus discriminability in visual search.

    PubMed

    Verghese, P; Nakayama, K

    1994-09-01

    We measured the probability of detecting the target in a visual search task, as a function of the following parameters: the discriminability of the target from the distractors, the duration of the display, and the number of elements in the display. We examined the relation between these parameters at criterion performance (80% correct) to determine if the parameters traded off according to the predictions of a limited capacity model. For the three dimensions that we studied, orientation, color, and spatial frequency, the observed relationship between the parameters deviates significantly from a limited capacity model. The data relating discriminability to display duration are better than predicted over the entire range of orientation and color differences that we examined, and are consistent with the prediction for only a limited range of spatial frequency differences--from 12 to 23%. The relation between discriminability and number varies considerably across the three dimensions and is better than the limited capacity prediction for two of the three dimensions that we studied. Orientation discrimination shows a strong number effect, color discrimination shows almost no effect, and spatial frequency discrimination shows an intermediate effect. The different trading relationships in each dimension are more consistent with early filtering in that dimension, than with a common limited capacity stage. Our results indicate that higher-level processes that group elements together also play a strong role. Our experiments provide little support for limited capacity mechanisms over the range of stimulus differences that we examined in three different dimensions.

  3. Assessment of Acoustic Adaptations for Noise Compensation in Marine Mammals

    DTIC Science & Technology

    2012-09-30

    Measurements of call parameters (include duration, frequency content, and receive level) and noise levels have been completed and the resulting article ...Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq - Brazilian government agency that issues such permits) by Universidade Federal de

  4. Incorporating Nonstationarity into IDF Curves across CONUS from Station Records and Implications

    NASA Astrophysics Data System (ADS)

    Wang, K.; Lettenmaier, D. P.

    2017-12-01

    Intensity-duration-frequency (IDF) curves are widely used for engineering design of storm-affected structures. Current practice is that IDF-curves are based on observed precipitation extremes fit to a stationary probability distribution (e.g., the extreme value family). However, there is increasing evidence of nonstationarity in station records. We apply the Mann-Kendall trend test to over 1000 stations across the CONUS at a 0.05 significance level, and find that about 30% of stations test have significant nonstationarity for at least one duration (1-, 2-, 3-, 6-, 12-, 24-, and 48-hours). We fit the stations to a GEV distribution with time-varying location and scale parameters using a Bayesian- methodology and compare the fit of stationary versus nonstationary GEV distributions to observed precipitation extremes. Within our fitted nonstationary GEV distributions, we compare distributions with a time-varying location parameter versus distributions with both time-varying location and scale parameters. For distributions with two time-varying parameters, we pay particular attention to instances where location and scale trends have opposing directions. Finally, we use the mathematical framework based on work of Koutsoyiannis to generate IDF curves based on the fitted GEV distributions and discuss the implications that using time-varying parameters may have on simple scaling relationships. We apply the above methods to evaluate how frequency statistics based on a stationary assumption compare to those that incorporate nonstationarity for both short and long term projects. Overall, we find that neglecting nonstationarity can lead to under- or over-estimates (depending on the trend for the given duration and region) of important statistics such as the design storm.

  5. Spatial hydrological drought characteristics in Karkheh River basin, southwest Iran using copulas

    NASA Astrophysics Data System (ADS)

    Dodangeh, Esmaeel; Shahedi, Kaka; Shiau, Jenq-Tzong; MirAkbari, Maryam

    2017-08-01

    Investigation on drought characteristics such as severity, duration, and frequency is crucial for water resources planning and management in a river basin. While the methodology for multivariate drought frequency analysis is well established by applying the copulas, the estimation on the associated parameters by various parameter estimation methods and the effects on the obtained results have not yet been investigated. This research aims at conducting a comparative analysis between the maximum likelihood parametric and non-parametric method of the Kendall τ estimation method for copulas parameter estimation. The methods were employed to study joint severity-duration probability and recurrence intervals in Karkheh River basin (southwest Iran) which is facing severe water-deficit problems. Daily streamflow data at three hydrological gauging stations (Tang Sazbon, Huleilan and Polchehr) near the Karkheh dam were used to draw flow duration curves (FDC) of these three stations. The Q_{75} index extracted from the FDC were set as threshold level to abstract drought characteristics such as drought duration and severity on the basis of the run theory. Drought duration and severity were separately modeled using the univariate probabilistic distributions and gamma-GEV, LN2-exponential, and LN2-gamma were selected as the best paired drought severity-duration inputs for copulas according to the Akaike Information Criteria (AIC), Kolmogorov-Smirnov and chi-square tests. Archimedean Clayton, Frank, and extreme value Gumbel copulas were employed to construct joint cumulative distribution functions (JCDF) of droughts for each station. Frank copula at Tang Sazbon and Gumbel at Huleilan and Polchehr stations were identified as the best copulas based on the performance evaluation criteria including AIC, BIC, log-likelihood and root mean square error (RMSE) values. Based on the RMSE values, nonparametric Kendall-τ is preferred to the parametric maximum likelihood estimation method. The results showed greater drought return periods by the parametric ML method in comparison to the nonparametric Kendall τ estimation method. The results also showed that stations located in tributaries (Huleilan and Polchehr) have close return periods, while the station along the main river (Tang Sazbon) has the smaller return periods for the drought events with identical drought duration and severity.

  6. Exploring short-GRB afterglow parameter space for observations in coincidence with gravitational waves

    NASA Astrophysics Data System (ADS)

    Saleem, M.; Resmi, L.; Misra, Kuntal; Pai, Archana; Arun, K. G.

    2018-03-01

    Short duration Gamma Ray Bursts (SGRB) and their afterglows are among the most promising electromagnetic (EM) counterparts of Neutron Star (NS) mergers. The afterglow emission is broad-band, visible across the entire electromagnetic window from γ-ray to radio frequencies. The flux evolution in these frequencies is sensitive to the multidimensional afterglow physical parameter space. Observations of gravitational wave (GW) from BNS mergers in spatial and temporal coincidence with SGRB and associated afterglows can provide valuable constraints on afterglow physics. We run simulations of GW-detected BNS events and assuming that all of them are associated with a GRB jet which also produces an afterglow, investigate how detections or non-detections in X-ray, optical and radio frequencies can be influenced by the parameter space. We narrow down the regions of afterglow parameter space for a uniform top-hat jet model, which would result in different detection scenarios. We list inferences which can be drawn on the physics of GRB afterglows from multimessenger astronomy with coincident GW-EM observations.

  7. Amitriptyline and aerobic exercise or amitriptyline alone in the treatment of chronic migraine: a randomized comparative study.

    PubMed

    Santiago, Michelle Dias Santos; Carvalho, Deusvenir de Souza; Gabbai, Alberto Alain; Pinto, Mariana Machado Pereira; Moutran, Andrea Regina Correa; Villa, Thais Rodrigues

    2014-11-01

    To compare the preventive treatment benefits of amitriptyline and aerobic exercise or amitriptyline alone in patients with chronic migraine. Sixty patients, both genders, aged between 18 and 50 years, with a diagnosis of chronic migraine, were randomized in groups called amitriptyline and aerobic exercise or amitriptyline alone. The following parameters were evaluated: headache frequency, intensity and duration of headache, days of the analgesic medication use, body mass index (BMI), Beck Depression Inventory (BDI) and Beck Anxiety Inventory (BAI) scores. In the evaluated parameters, was observed decrease in headache frequency (p=0.001), moderate intensity (p=0.048), in headache duration (p=0.001), the body mass index (p=0.001), Beck Depression Inventory (p=0.001) and Beck Anxiety Inventory scores (p=0.001), when groups were compared in the end of third month. In this study, the amitriptyline was an effective treatment for chronic migraine, but its efficacy was increased when combined with aerobic exercise.

  8. Estimation of effect of hydrogen on the parameters of magnetoacoustic emission signals

    NASA Astrophysics Data System (ADS)

    Skalskyi, Valentyn; Stankevych, Olena; Dubytskyi, Olexandr

    2018-05-01

    The features of the magnetoacoustic emission (MAE) signals during magnetization of structural steels with the different degree of hydrogenating were investigated by the wavelet transform. The dominant frequency ranges of MAE signals for the different magnetic field strength were determined using Discrete Wavelet Transform (DWT), and the energy and spectral parameters of MAE signals were determined using Continuous Wavelet Transform (CWT). The characteristic differences of the local maximums of signals according to energy, bandwidth, duration and frequency were found. The methodology of estimation of state of local degradation of materials by parameters of wavelet transform of MAE signals was proposed. This methodology was approbated for investigate of state of long-time exploitations structural steels of oil and gas pipelines.

  9. Changes in heat wave characteristics over Extremadura (SW Spain)

    NASA Astrophysics Data System (ADS)

    Acero, Francisco Javier; Fernández-Fernández, María Isabel; Carrasco, Víctor Manuel Sánchez; Parey, Sylvie; Hoang, Thi Thu Huong; Dacunha-Castelle, Didier; García, José Agustín

    2017-07-01

    Heat wave (HW) events are becoming more frequent, and they have important consequences because of the negative effects they can have not only on the human population in health terms but also on biodiversity and agriculture. This motivated a study of the trends in HW events over Extremadura, a region in the southwest of Spain, with much of its area in summer devoted to the production of irrigated crops such as maize and tomatoes. Heat waves were defined for the study as two consecutive days with temperatures above the 95th percentile of the summer (June-August) maximum temperature (T max) time series. Two datasets were used: One consisted of 13 daily temperature records uniformly distributed over the Region, and the other was the SPAIN02 gridded observational dataset, extracting just the points corresponding to Extremadura. The trends studied were in the duration, intensity and frequency of HW events, and in other parameters such as the mean, low (25th percentile) and high (75th percentile) values. In general terms, the results showed significant positive trends in those parameters over the east, the northwest and a small area in the south of the region. In order to study changes in HW characteristics (duration, frequency and intensity) considering different subperiods, a stochastic model was used to generate 1000 time series equivalent to the observed ones. The results showed that there were no significant changes in HW duration in the last 10-year subperiod in comparison with the first. But, the results were different for warm events (WE), defined with a lower threshold (the 75th percentile), which are also important for agriculture. For several sites, there were significant changes in WE duration, frequency and intensity.

  10. Effects of photosynthetic photon flux density, frequency, duty ratio, and their interactions on net photosynthetic rate of cos lettuce leaves under pulsed light: explanation based on photosynthetic-intermediate pool dynamics.

    PubMed

    Jishi, Tomohiro; Matsuda, Ryo; Fujiwara, Kazuhiro

    2018-06-01

    Square-wave pulsed light is characterized by three parameters, namely average photosynthetic photon flux density (PPFD), pulsed-light frequency, and duty ratio (the ratio of light-period duration to that of the light-dark cycle). In addition, the light-period PPFD is determined by the averaged PPFD and duty ratio. We investigated the effects of these parameters and their interactions on net photosynthetic rate (P n ) of cos lettuce leaves for every combination of parameters. Averaged PPFD values were 0-500 µmol m -2  s -1 . Frequency values were 0.1-1000 Hz. White LED arrays were used as the light source. Every parameter affected P n and interactions between parameters were observed for all combinations. The P n under pulsed light was lower than that measured under continuous light of the same averaged PPFD, and this difference was enhanced with decreasing frequency and increasing light-period PPFD. A mechanistic model was constructed to estimate the amount of stored photosynthetic intermediates over time under pulsed light. The results indicated that all effects of parameters and their interactions on P n were explainable by consideration of the dynamics of accumulation and consumption of photosynthetic intermediates.

  11. Study and Optimization of CPT Resonance Parameters in 87 Rb/Ar/Ne Microcells Aimed for Application in Metrology

    NASA Astrophysics Data System (ADS)

    Masian, Y.; Sivak, A.; Sevostianov, D.; Vassiliev, V.; Velichansky, V.

    The paper shows the presents results of studies of small-size rubidium cells with argon and neon buffer gases, produced by a patent pended technique of laser welding [Fishman et al. (2014)]. Cells were designed for miniature frequency standard. Temperature dependence of the frequency of the coherent population trapping (CPT) resonance was measured and used to optimize the ratio of partial pressures of buffer gases. The influence of duration and regime of annealing on the CPT-resonance frequency drift was investigated. The parameters of the FM modulation of laser current for two cases which correspond to the highest amplitude of CPT resonance and to the smallest light shifts of the resonance frequency were determined. The temperature dependences of the CPT resonance frequency were found to be surprisingly different in the two cases. A non-linear dependence of CPT resonance frequency on the temperature of the cell with the two extremes was revealed for one of these cases.

  12. Neuromuscular Electrical Stimulation for Skeletal Muscle Function

    PubMed Central

    Doucet, Barbara M.; Lam, Amy; Griffin, Lisa

    2012-01-01

    Lack of neural innervation due to neurological damage renders muscle unable to produce force. Use of electrical stimulation is a medium in which investigators have tried to find a way to restore movement and the ability to perform activities of daily living. Different methods of applying electrical current to modify neuromuscular activity are electrical stimulation (ES), neuromuscular electrical stimulation (NMES), transcutaneous electrical nerve stimulation (TENS), and functional electrical stimulation (FES). This review covers the aspects of electrical stimulation used for rehabilitation and functional purposes. Discussed are the various parameters of electrical stimulation, including frequency, pulse width/duration, duty cycle, intensity/amplitude, ramp time, pulse pattern, program duration, program frequency, and muscle group activated, and how they affect fatigue in the stimulated muscle. PMID:22737049

  13. Cooling the vertical surface by conditionally single pulses

    NASA Astrophysics Data System (ADS)

    Karpov, Pavel; Nazarov, Alexander; Serov, Anatoly; Terekhov, Victor

    2017-10-01

    You Sprays with periodic supply of the droplet phase have great opportunities to control the heat exchange processes. Varying pulse duration and frequency of their repetition, we can achieve the optimal conditions of evaporative cooling with minimization of the liquid flow rate. The paper presents experimental data on studying local heat transfer on a large subcooled surface, obtained on the original setup with multinozzle controlled system of impact irrigation by the gas-droplet flow. A contribution to intensification of the spray parameters (flow rate, pulse duration, repetition frequency) per a growth of integral heat transfer was studied. Data on instantaneous distribution of the heat flux value helped us to describe the processes occurring on the studied surface. These data could describe the regime of "island" film cooling.

  14. Epidural blood patch for refractory low CSF pressure headache: a pilot study.

    PubMed

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-08-01

    Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication/month). In our primary effect parameter we found a significant reduction in AUC with more than 25% and this is considered to be clinically relevant. We found also a significant and relevant reduction at -22% in intensity. A trend towards reduction in duration was seen. We found no statistically significant reduction in frequency. An increase in days with use of medication was found. Increased awareness of low CSF pressure headache is emphasized and a controlled larger randomized study is needed to confirm the results. However the present results, allows us to conclude that EBP in treatment-refractory low CSF pressure headache can be considered as a treatment option.

  15. Perinatal maturation of the mouse respiratory rhythm-generator: in vivo and in vitro studies.

    PubMed

    Viemari, Jean-Charles; Burnet, Henri; Bévengut, Michelle; Hilaire, Gérard

    2003-03-01

    In vivo (plethysmography) and in vitro (en bloc preparations) experiments were performed from embryonic day 16 (E16) to postnatal day 9 (P9) in order to analyse the perinatal maturation of the respiratory rhythm-generator in mice. At E16, delivered foetuses did not ventilate and survive but at E18 they breathed at about 110 cycles/min with respiratory cycles of variable individual duration. From E18 to P0-P2, the respiratory cycles stabilised without changes in the breathing parameters. However, these increased several-fold during the next days. Hypoxia increased breathing frequency from E18-P5 and only significantly affected ventilation from P3 onwards. At E16, in vitro medullary preparations (pons resection) produced rhythmic phrenic bursts at a low frequency (about 5 cycles/min) with variable cycle duration. At E18, their frequency doubled but cycle duration remained variable. After birth, the frequency did not change although cycle duration stabilised. At E18 and P0-P2, the in vitro frequency decreased by around 50% under hypoxia, increased by 40-50% under noradrenaline or substance P and was permanently depressed by the pontine A5 areas. At E16 however, hypoxia had no effects, both noradrenaline and substance P drastically increased the frequency and area A5 inhibition was not expressed at this time. At E18 and P0-P2, electrical stimulation and electrolytic lesion of the rostral ventrolateral medulla affected the in vitro rhythm but failed to induce convincing effects at E16. Thus, a major maturational step in respiratory rhythmogenesis occurs between E16-E18, in agreement with the concept of multiple rhythmogenic mechanisms.

  16. The influence of fundamental frequency on perceived duration in spectrally comparable sounds

    PubMed Central

    Aalto, Daniel; Simko, Juraj; Vainio, Martti

    2017-01-01

    The perceived duration of a sound is affected by its fundamental frequency and intensity: higher sounds are judged to be longer, as are sounds with greater intensity. Since increasing intensity lengthens the perceived duration of the auditory object, and increasing the fundamental frequency increases the sound’s perceived loudness (up to ca. 3 kHz), frequency modulation of duration could be potentially explained by a confounding effect where the primary cause of the modulation would be variations in intensity. Here, a series of experiments are described that were designed to disentangle the contributions of fundamental frequency, intensity, and duration to perceived loudness and duration. In two forced-choice tasks, participants judged duration and intensity differences between two sounds varying simultaneously in intensity, fundamental frequency, fundamental frequency gliding range, and duration. The results suggest that fundamental frequency and intensity each have an impact on duration judgments, while frequency gliding range did not influence the present results. We also demonstrate that the modulation of perceived duration by sound fundamental frequency cannot be fully explained by the confounding relationship between frequency and intensity. PMID:28879063

  17. The influence of fundamental frequency on perceived duration in spectrally comparable sounds.

    PubMed

    Dawson, Caitlin; Aalto, Daniel; Simko, Juraj; Vainio, Martti

    2017-01-01

    The perceived duration of a sound is affected by its fundamental frequency and intensity: higher sounds are judged to be longer, as are sounds with greater intensity. Since increasing intensity lengthens the perceived duration of the auditory object, and increasing the fundamental frequency increases the sound's perceived loudness (up to ca. 3 kHz), frequency modulation of duration could be potentially explained by a confounding effect where the primary cause of the modulation would be variations in intensity. Here, a series of experiments are described that were designed to disentangle the contributions of fundamental frequency, intensity, and duration to perceived loudness and duration. In two forced-choice tasks, participants judged duration and intensity differences between two sounds varying simultaneously in intensity, fundamental frequency, fundamental frequency gliding range, and duration. The results suggest that fundamental frequency and intensity each have an impact on duration judgments, while frequency gliding range did not influence the present results. We also demonstrate that the modulation of perceived duration by sound fundamental frequency cannot be fully explained by the confounding relationship between frequency and intensity.

  18. Dependence the Integrated Energy of the Electromagnetic Response from Excitation Pulse Duration for Epoxy Samples With Sand Filler

    NASA Astrophysics Data System (ADS)

    Surzhikov, V. P.; Demikhova, A. A.

    2017-01-01

    Results of research of influence of the excitation pulse duration on the parameters of the electromagnetic response of epoxy samples with filler the quartz sand presented in the paper. The electric component of a response was registered by the capacitive sensors using a differential amplifier. Measurements were carried out at two frequencies of the master generator of 65 kHz and 74 kHz. The pulse duration was changing from 10 to 100 microseconds. The stepped sort of dependence of the integrated oscillations energy in the response from duration of the excitation pulse was discovered. The conclusion was made about the determining role of the normal oscillations in formation of such dependence.

  19. Simulation of gait and gait initiation associated with body oscillating behavior in the gravity environment on the moon, mars and Phobos.

    PubMed

    Brenière, Y

    2001-04-01

    A double-inverted pendulum model of body oscillations in the frontal plane during stepping [Brenière and Ribreau (1998) Biol Cybern 79: 337-345] proposed an equivalent model for studying the body oscillating behavior induced by step frequency in the form of: (1) a kinetic body parameter, the natural body frequency (NBF), which contains gravity and which is invariable for humans, (2) a parametric function of frequency, whose parameter is the NBF, which explicates the amplitude ratio of center of mass to center of foot pressure oscillation, and (3) a function of frequency which simulates the equivalent torque necessary for the control of the head-arms-trunk segment oscillations. Here, this equivalent model is used to simulate the duration of gait initiation, i.e., the duration necessary to initiate and execute the first step of gait in subgravity, as well as to calculate the step frequencies that would impose the same minimum and maximum amplitudes of the oscillating responses of the body center of mass, whatever the gravity value. In particular, this simulation is tested under the subgravity conditions of the Moon, Mars, and Phobos, where gravity is 1/6, 3/8, and 1/1600 times that on the Earth, respectively. More generally, the simulation allows us to establish and discuss the conditions for gait adaptability that result from the biomechanical constraints particular to each gravity system.

  20. Effect of the combination of different welding parameters on melting characteristics of grade 1 titanium with a pulsed Nd-Yag laser.

    PubMed

    Bertrand, C; Laplanche, O; Rocca, J P; Le Petitcorps, Y; Nammour, S

    2007-11-01

    The laser is a very attractive tool for joining dental metallic alloys. However, the choice of the setting parameters can hardly influence the welding performances. The aim of this research was to evaluate the impact of several parameters (pulse shaping, pulse frequency, focal spot size...) on the quality of the microstructure. Grade 1 titanium plates have been welded with a pulsed Nd-Yag laser. Suitable power, pulse duration, focal spot size, and flow of argon gas were fixed by the operator. Five different pulse shapes and three pulse frequencies were investigated. Two pulse shapes available on this laser unit were eliminated because they considerably hardened the metal. As the pulse frequency rose, the metal was more and more ejected, and a plasma on the surface of the metal increased the oxygen contamination in the welded area. Frequencies of 1 or 2 Hz are optimum for a dental use. Three pulse shapes can be used for titanium but the rectangular shape gives better results.

  1. Decimetre Waves and Cerebellar Cortex Key Element - Purkinje Cells

    NASA Astrophysics Data System (ADS)

    Maharramov, Akif A.

    2007-04-01

    Acute experiments have been carried out on both decerebrated and anaesthetized adult cats exposed to Decimetre Range Microwaves (DRM) (λ=65 cm, duration of exposition -10 min., at least) by the help of a 2 cm radius contact applicator located on the temple part of the head with cerebellum in the centre of projection of irradiation conducted from portable physiotherapeutic apparatus ``Romashka''. Extracelullar registration of Purkinje Cells (PC) impulse activities have been led by glass microelectrodes. Statistical and computational analyses of PC activities have been realized by the help of histograms - the characteristic distribution of the number of interimpulse intervals (II) between electrical discharges of a neuron on the II durations, drawn up by the help of a computer. The results obtained revealed the reaction of PC to DRM as a succession of starting to react of PC electrophysiological parameters, beginning from decreasing of known ``Inhibitory Pause'' duration, and further, at first, ``Simple Spikes'' then ``Complex Spikes'' frequencies' increase, and furthermore, durations' increase in ``Big Interimpulse Intervals'', parameter, introduced for the first time by us, in this way, showing the ``evolutionary'' nature of Electromagnetic Fields and Living object interactions.

  2. Decreased frequency and duration of tooth brushing is a risk factor for endothelial dysfunction.

    PubMed

    Matsui, Shogo; Kajikawa, Masato; Maruhashi, Tatsuya; Iwamoto, Yumiko; Iwamoto, Akimichi; Oda, Nozomu; Kishimoto, Shinji; Hidaka, Takayuki; Kihara, Yasuki; Chayama, Kazuaki; Goto, Chikara; Aibara, Yoshiki; Nakashima, Ayumu; Noma, Kensuke; Taguchi, Akira; Higashi, Yukihito

    2017-08-15

    Periodontal disease is associated with endothelial dysfunction, leading to cardiovascular disease. The effect of detailed tooth brushing behavior, not only frequency but also duration of tooth brushing, on endothelial function is unclear. The purpose of this study was to evaluate the relationships of detailed methods of tooth brushing with vascular function. We evaluated flow-mediated vasodilation (FMD), nitroglycerine-induced vasodilation, and frequency and duration of tooth brushing in 896 subjects. We divided the subjects into three groups according to the frequency and duration of tooth brushing: low frequency and short duration group (

  3. Characteristics of retinal reflectance changes induced by transcorneal electrical stimulation in cat eyes.

    PubMed

    Morimoto, Takeshi; Kanda, Hiroyuki; Miyoshi, Tomomitsu; Hirohara, Yoko; Mihashi, Toshifumi; Kitaguchi, Yoshiyuki; Nishida, Kohji; Fujikado, Takashi

    2014-01-01

    Transcorneal electrical stimulation (TES) activates retinal neurons leading to visual sensations. How the retinal cells are activated by TES has not been definitively determined. Investigating the reflectance changes of the retina is an established technique and has been used to determine the mechanism of retinal activation. The purpose of this study was to evaluate the reflectance changes elicited by TES in cat eyes. Eight eyes of Eight cats were studied under general anesthesia. Biphasic electrical pulses were delivered transcornealy. The fundus images observed with near-infrared light (800-880 nm) were recorded every 25 ms for 26 s. To improve the signal-to-noise ratio, the images of 10 consecutive recordings were averaged. Two-dimensional topographic maps of the reflective changes were constructed by subtracting images before from those after the TES. The effects of different stimulus parameters, e.g., current intensity, pulse duration, frequency, and stimulus duration, on the reflective changes were studied. Our results showed that after TES, the reflective changes appeared on the retinal vessels and optic disc. The intensity of reflectance changes increased as the current intensity, pulse duration, and stimulation duration increased (P<0.05 for all). The maximum intensity of the reflective change was obtained when the stimulus frequency was 20 Hz. The time course of the reflectance changes was also altered by the stimulation parameters. The response started earlier and returned to the baseline later with higher current intensities, longer pulse durations, but the time of the peak of the response was not changed. These results showed that the reflective changes were due to the activation of retinal neurons by TES and might involve the vascular changes induced by an activation of the retinal neurons.

  4. Optimal parameters of transcorneal electrical stimulation (TES) to be neuroprotective of axotomized RGCs in adult rats.

    PubMed

    Morimoto, Takeshi; Miyoshi, Tomomitsu; Sawai, Hajime; Fujikado, Takashi

    2010-02-01

    We previously showed that transcorneal electrical stimulation (TES) promoted the survival of axotomized retinal ganglion cells (RGCs) of rats. However the relationship between the parameters of TES and the neuroprotective effect of TES on axotomized RGCs was unclear. In the present study, we determined whether the neuroprotective effect of TES is affected by the parameters of TES. Adult male Wistar rats received TES just after transection of the left optic nerve (ON). The pulse duration, current intensity, frequency, waveform, and numbers of sessions of the TES were changed systematically. The alterations of the retina were examined histologically seven days or fourteen days after the ON transection. The optimal neuroprotective parameters were pulse duration of 1 and 2 ms/phase (P < 0.001, each), current intensity of 100 and 200 muA (P < 0.05, each), and stimulation frequency of 1, 5, and 20 Hz (P < 0.001, respectively). More than 30 min of TES was necessary to have a neuroprotective effect (P < 0.001). Symmetric pulses without an inter-pulse interval were most effective (P < 0.001). Repeated TES was more neuroprotective than a single TES at 14 days after ON transection (P < 0.001). Our results indicate that there is a range of optimal neuroprotective parameters of TES for axotomized RGCs of rats. These values will provide a guideline for the use of TES in patients with different retinal and optic nerve diseases. Copyright 2009 Elsevier Ltd. All rights reserved.

  5. Estimation of optimal hologram recording modes on photothermal materials

    NASA Astrophysics Data System (ADS)

    Dzhamankyzov, Nasipbek Kurmanalievich; Ismanov, Yusupzhan Khakimzhanovich; Zhumaliev, Kubanychbek Myrzabekovich; Alymkulov, Samsaly Amanovich

    2018-01-01

    A theoretical analysis of the hologram recording process on photothermal media to estimate the required laser radiation power for the information recording as the function of the spatial frequency and radiation exposure duration is considered. Results of the analysis showed that materials with a low thermal diffusivity are necessary to increase the recording density in these media and the recording should be performed with short pulses to minimize the thermal diffusion length. A solution for the heat conduction equation for photothermal materials heated by an interference laser field was found. The solution obtained allows one to determine the required value of the recording temperature for given spatial frequencies, depending on the thermal physical parameters of the medium and on the power and duration of the heating radiation.

  6. Evaluation of the best fit distribution for partial duration series of daily rainfall in Madinah, western Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Alahmadi, F.; Rahman, N. A.; Abdulrazzak, M.

    2014-09-01

    Rainfall frequency analysis is an essential tool for the design of water related infrastructure. It can be used to predict future flood magnitudes for a given magnitude and frequency of extreme rainfall events. This study analyses the application of rainfall partial duration series (PDS) in the vast growing urban Madinah city located in the western part of Saudi Arabia. Different statistical distributions were applied (i.e. Normal, Log Normal, Extreme Value type I, Generalized Extreme Value, Pearson Type III, Log Pearson Type III) and their distribution parameters were estimated using L-moments methods. Also, different selection criteria models are applied, e.g. Akaike Information Criterion (AIC), Corrected Akaike Information Criterion (AICc), Bayesian Information Criterion (BIC) and Anderson-Darling Criterion (ADC). The analysis indicated the advantage of Generalized Extreme Value as the best fit statistical distribution for Madinah partial duration daily rainfall series. The outcome of such an evaluation can contribute toward better design criteria for flood management, especially flood protection measures.

  7. The Impact of Attention on Judgments of Frequency and Duration

    PubMed Central

    Winkler, Isabell; Glauer, Madlen; Betsch, Tilmann; Sedlmeier, Peter

    2015-01-01

    Previous studies that examined human judgments of frequency and duration found an asymmetrical relationship: While frequency judgments were quite accurate and independent of stimulus duration, duration judgments were highly dependent upon stimulus frequency. A potential explanation for these findings is that the asymmetry is moderated by the amount of attention directed to the stimuli. In the current experiment, participants' attention was manipulated in two ways: (a) intrinsically, by varying the type and arousal potential of the stimuli (names, low-arousal and high-arousal pictures), and (b) extrinsically, by varying the physical effort participants expended during the stimulus presentation (by lifting a dumbbell vs. relaxing the arm). Participants processed stimuli with varying presentation frequencies and durations and were subsequently asked to estimate the frequency and duration of each stimulus. Sensitivity to duration increased for pictures in general, especially when processed under physical effort. A large effect of stimulus frequency on duration judgments was obtained for all experimental conditions, but a similar large effect of presentation duration on frequency judgments emerged only in the conditions that could be expected to draw high amounts of attention to the stimuli: when pictures were judged under high physical effort. Almost no difference in the mutual impact of frequency and duration was obtained for low-arousal or high-arousal pictures. The mechanisms underlying the simultaneous processing of frequency and duration are discussed with respect to existing models derived from animal research. Options for the extension of such models to human processing of frequency and duration are suggested. PMID:26000712

  8. The impact of attention on judgments of frequency and duration.

    PubMed

    Winkler, Isabell; Glauer, Madlen; Betsch, Tilmann; Sedlmeier, Peter

    2015-01-01

    Previous studies that examined human judgments of frequency and duration found an asymmetrical relationship: While frequency judgments were quite accurate and independent of stimulus duration, duration judgments were highly dependent upon stimulus frequency. A potential explanation for these findings is that the asymmetry is moderated by the amount of attention directed to the stimuli. In the current experiment, participants' attention was manipulated in two ways: (a) intrinsically, by varying the type and arousal potential of the stimuli (names, low-arousal and high-arousal pictures), and (b) extrinsically, by varying the physical effort participants expended during the stimulus presentation (by lifting a dumbbell vs. relaxing the arm). Participants processed stimuli with varying presentation frequencies and durations and were subsequently asked to estimate the frequency and duration of each stimulus. Sensitivity to duration increased for pictures in general, especially when processed under physical effort. A large effect of stimulus frequency on duration judgments was obtained for all experimental conditions, but a similar large effect of presentation duration on frequency judgments emerged only in the conditions that could be expected to draw high amounts of attention to the stimuli: when pictures were judged under high physical effort. Almost no difference in the mutual impact of frequency and duration was obtained for low-arousal or high-arousal pictures. The mechanisms underlying the simultaneous processing of frequency and duration are discussed with respect to existing models derived from animal research. Options for the extension of such models to human processing of frequency and duration are suggested.

  9. Effects of laser source parameters on the generation of narrow band and directed laser ultrasound

    NASA Technical Reports Server (NTRS)

    Spicer, James B.; Deaton, John B., Jr.; Wagner, James W.

    1992-01-01

    Predictive and prescriptive modeling of laser arrays is performed to demonstrate the effects of the extension of array elements on laser array performance. For a repetitively pulsed laser source (the temporal laser array), efficient frequency compression is best achieved by detecting longitudinal waves off-epicenter in plates where the source size and shape directly influence the longitudinal wave shape and duration; the longitudinal array may be tailored for a given repetition frequency to yield efficient overtone energy compression into the fundamental frequency band. For phased arrays, apparent array directivity is heavily influenced by array element size.

  10. Short-Term Dosage Regimen for Stimulation-Induced Long-Lasting Desynchronization.

    PubMed

    Manos, Thanos; Zeitler, Magteld; Tass, Peter A

    2018-01-01

    In this paper, we computationally generate hypotheses for dose-finding studies in the context of desynchronizing neuromodulation techniques. Abnormally strong neuronal synchronization is a hallmark of several brain disorders. Coordinated Reset (CR) stimulation is a spatio-temporally patterned stimulation technique that specifically aims at disrupting abnormal neuronal synchrony. In networks with spike-timing-dependent plasticity CR stimulation may ultimately cause an anti-kindling, i.e., an unlearning of abnormal synaptic connectivity and neuronal synchrony. This long-lasting desynchronization was theoretically predicted and verified in several pre-clinical and clinical studies. We have shown that CR stimulation with rapidly varying sequences (RVS) robustly induces an anti-kindling at low intensities e.g., if the CR stimulation frequency (i.e., stimulus pattern repetition rate) is in the range of the frequency of the neuronal oscillation. In contrast, CR stimulation with slowly varying sequences (SVS) turned out to induce an anti-kindling more strongly, but less robustly with respect to variations of the CR stimulation frequency. Motivated by clinical constraints and inspired by the spacing principle of learning theory, in this computational study we propose a short-term dosage regimen that enables a robust anti-kindling effect of both RVS and SVS CR stimulation, also for those parameter values where RVS and SVS CR stimulation previously turned out to be ineffective. Intriguingly, for the vast majority of parameter values tested, spaced multishot CR stimulation with demand-controlled variation of stimulation frequency and intensity caused a robust and pronounced anti-kindling. In contrast, spaced CR stimulation with fixed stimulation parameters as well as singleshot CR stimulation of equal integral duration failed to improve the stimulation outcome. In the model network under consideration, our short-term dosage regimen enables to robustly induce long-term desynchronization at comparably short stimulation duration and low integral stimulation duration. Currently, clinical proof of concept is available for deep brain CR stimulation for Parkinson's therapy and acoustic CR stimulation for tinnitus therapy. Promising first in human data is available for vibrotactile CR stimulation for Parkinson's treatment. For the clinical development of these treatments it is mandatory to perform dose-finding studies to reveal optimal stimulation parameters and dosage regimens. Our findings can straightforwardly be tested in human dose-finding studies.

  11. Short-Term Dosage Regimen for Stimulation-Induced Long-Lasting Desynchronization

    PubMed Central

    Manos, Thanos; Zeitler, Magteld; Tass, Peter A.

    2018-01-01

    In this paper, we computationally generate hypotheses for dose-finding studies in the context of desynchronizing neuromodulation techniques. Abnormally strong neuronal synchronization is a hallmark of several brain disorders. Coordinated Reset (CR) stimulation is a spatio-temporally patterned stimulation technique that specifically aims at disrupting abnormal neuronal synchrony. In networks with spike-timing-dependent plasticity CR stimulation may ultimately cause an anti-kindling, i.e., an unlearning of abnormal synaptic connectivity and neuronal synchrony. This long-lasting desynchronization was theoretically predicted and verified in several pre-clinical and clinical studies. We have shown that CR stimulation with rapidly varying sequences (RVS) robustly induces an anti-kindling at low intensities e.g., if the CR stimulation frequency (i.e., stimulus pattern repetition rate) is in the range of the frequency of the neuronal oscillation. In contrast, CR stimulation with slowly varying sequences (SVS) turned out to induce an anti-kindling more strongly, but less robustly with respect to variations of the CR stimulation frequency. Motivated by clinical constraints and inspired by the spacing principle of learning theory, in this computational study we propose a short-term dosage regimen that enables a robust anti-kindling effect of both RVS and SVS CR stimulation, also for those parameter values where RVS and SVS CR stimulation previously turned out to be ineffective. Intriguingly, for the vast majority of parameter values tested, spaced multishot CR stimulation with demand-controlled variation of stimulation frequency and intensity caused a robust and pronounced anti-kindling. In contrast, spaced CR stimulation with fixed stimulation parameters as well as singleshot CR stimulation of equal integral duration failed to improve the stimulation outcome. In the model network under consideration, our short-term dosage regimen enables to robustly induce long-term desynchronization at comparably short stimulation duration and low integral stimulation duration. Currently, clinical proof of concept is available for deep brain CR stimulation for Parkinson's therapy and acoustic CR stimulation for tinnitus therapy. Promising first in human data is available for vibrotactile CR stimulation for Parkinson's treatment. For the clinical development of these treatments it is mandatory to perform dose-finding studies to reveal optimal stimulation parameters and dosage regimens. Our findings can straightforwardly be tested in human dose-finding studies. PMID:29706900

  12. Low-frequency oscillation amplitude elevation of prefrontal cerebral hemodynamics with driving duration during prolonged driving test

    NASA Astrophysics Data System (ADS)

    Deng, Zishan; Gao, Yuan; Li, Ting

    2018-02-01

    It has been observed that there is a low-frequency oscillation (LFO) around 0.1 Hz in cerebral hemodynamics related to brain activity. Since functional near-infrared spectroscopy (fNIRS) is a novel technique to monitor hemodynamic responses noninvasively, we applied it to detect LFOs of cerebral hemodynamic parameters, such as oxyhemoglobin and deoxyhemoglobin, during prolonged driving. We performed an experiment lasting for 7 hours and an experimental test was done every hour and 8 times altogether. 7 subjects were recruited and the data of 3 of them were analyzed. By means of Fourier transformation, the amplitude of the three parameters during each test at 0.1 Hz in frequency domain was extracted. The results showed an increasing trend in the 0.1 Hz amplitudes of the three hemodynamic parameters during 7 hours' simulated driving test. Our findings indicated the potential of LFOs of prefrontal cerebral hemodynamics in brain research and brain function evaluation.

  13. Input design for identification of aircraft stability and control derivatives

    NASA Technical Reports Server (NTRS)

    Gupta, N. K.; Hall, W. E., Jr.

    1975-01-01

    An approach for designing inputs to identify stability and control derivatives from flight test data is presented. This approach is based on finding inputs which provide the maximum possible accuracy of derivative estimates. Two techniques of input specification are implemented for this objective - a time domain technique and a frequency domain technique. The time domain technique gives the control input time history and can be used for any allowable duration of test maneuver, including those where data lengths can only be of short duration. The frequency domain technique specifies the input frequency spectrum, and is best applied for tests where extended data lengths, much longer than the time constants of the modes of interest, are possible. These technqiues are used to design inputs to identify parameters in longitudinal and lateral linear models of conventional aircraft. The constraints of aircraft response limits, such as on structural loads, are realized indirectly through a total energy constraint on the input. Tests with simulated data and theoretical predictions show that the new approaches give input signals which can provide more accurate parameter estimates than can conventional inputs of the same total energy. Results obtained indicate that the approach has been brought to the point where it should be used on flight tests for further evaluation.

  14. Low Intensity and Frequency Pulsed Electromagnetic Fields Selectively Impair Breast Cancer Cell Viability

    PubMed Central

    Crocetti, Sara; Beyer, Christian; Schade, Grit; Egli, Marcel; Fröhlich, Jürg; Franco-Obregón, Alfredo

    2013-01-01

    Introduction A common drawback of many anticancer therapies is non-specificity in action of killing. We investigated the potential of ultra-low intensity and frequency pulsed electromagnetic fields (PEMFs) to kill breast cancer cells. Our criteria to accept this technology as a potentially valid therapeutic approach were: 1) cytotoxicity to breast cancer cells and; 2) that the designed fields proved innocuous to healthy cell classes that would be exposed to the PEMFs during clinical treatment. Methods MCF7 breast cancer cells and their normal counterparts, MCF10 cells, were exposed to PEMFs and cytotoxic indices measured in order to design PEMF paradigms that best kill breast cancer cells. The PEMF parameters tested were: 1) frequencies ranging from 20 to 50 Hz; 2) intensities ranging from 2 mT to 5 mT and; 3) exposure durations ranging from 30 to 90 minutes per day for up to three days to determine the optimum parameters for selective cancer cell killing. Results We observed a discrete window of vulnerability of MCF7 cells to PEMFs of 20 Hz frequency, 3 mT magnitude and exposure duration of 60 minutes per day. The cell damage accrued in response to PEMFs increased with time and gained significance after three days of consecutive daily exposure. By contrast, the PEMFs parameters determined to be most cytotoxic to breast cancer MCF-7 cells were not damaging to normal MCF-10 cells. Conclusion Based on our data it appears that PEMF-based anticancer strategies may represent a new therapeutic approach to treat breast cancer without affecting normal tissues in a manner that is non-invasive and can be potentially combined with existing anti-cancer treatments. PMID:24039828

  15. Acoustic and Perceptual Profiles of Swallowing Sounds in Children: Normative Data for 4-36 Months from a Cross-Sectional Study Cohort.

    PubMed

    Frakking, Thuy T; Chang, Anne B; O'Grady, Kerry-Ann F; Yang, Julie; David, Michael; Weir, Kelly A

    2017-04-01

    Limited data on cervical auscultation (CA) sounds during the transitional feeding period of 4-36 months in healthy children exist. This study examined the acoustic and perceptual parameters of swallowing sounds in children aged 4-36 months over a range of food and fluid consistencies. Using CA, swallowing sounds were recorded from a microphone as children ate or drank. Acoustic parameters of duration, peak frequency and peak intensity were determined. Perceptual parameters of swallowing/breath sounds heard pre-, during and post-swallow were rated ('present', 'absent', 'cannot be determined') for each texture. 74 children (35 males; mean age = 17.1 months [SD 10.0]) demonstrated mean swallow durations of <1 s. Increasing age correlated to reduced peak frequency on puree (r = -0.48, 95 % CI -0.66, -0.24). Age correlated to peak amplitude when swallowing puree (r = 0.27, 95 % CI 0.02, 0.49), chewable solids (r = 0.31, 95 % CI 0.02, 0.56) and thin fluids (r = 0.48, 95 % CI 0.27, 0.64). The bolus transit sound was present in all swallows. A majority of children had normal breathing sounds and coordinated swallows. A swallow duration of <1 s and the presence of a quick bolus transit sound with normal breathing sounds were found in healthy children. The normative data reported in this study provide a platform for future comparison to abnormal swallowing sounds in children.

  16. Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables.

    PubMed

    Baek, Hyun Jae; Shin, JaeWook

    2017-08-15

    Most of the wrist-worn devices on the market provide a continuous heart rate measurement function using photoplethysmography, but have not yet provided a function to measure the continuous heart rate variability (HRV) using beat-to-beat pulse interval. The reason for such is the difficulty of measuring a continuous pulse interval during movement using a wearable device because of the nature of photoplethysmography, which is susceptible to motion noise. This study investigated the effect of missing heart beat interval data on the HRV analysis in cases where pulse interval cannot be measured because of movement noise. First, we performed simulations by randomly removing data from the RR interval of the electrocardiogram measured from 39 subjects and observed the changes of the relative and normalized errors for the HRV parameters according to the total length of the missing heart beat interval data. Second, we measured the pulse interval from 20 subjects using a wrist-worn device for 24 h and observed the error value for the missing pulse interval data caused by the movement during actual daily life. The experimental results showed that mean NN and RMSSD were the most robust for the missing heart beat interval data among all the parameters in the time and frequency domains. Most of the pulse interval data could not be obtained during daily life. In other words, the sample number was too small for spectral analysis because of the long missing duration. Therefore, the frequency domain parameters often could not be calculated, except for the sleep state with little motion. The errors of the HRV parameters were proportional to the missing data duration in the presence of missing heart beat interval data. Based on the results of this study, the maximum missing duration for acceptable errors for each parameter is recommended for use when the HRV analysis is performed on a wrist-worn device.

  17. Glycemic penalty index for adequately assessing and comparing different blood glucose control algorithms

    PubMed Central

    Van Herpe, Tom; De Brabanter, Jos; Beullens, Martine; De Moor, Bart; Van den Berghe, Greet

    2008-01-01

    Introduction Blood glucose (BG) control performed by intensive care unit (ICU) nurses is becoming standard practice for critically ill patients. New (semi-automated) 'BG control' algorithms (or 'insulin titration' algorithms) are under development, but these require stringent validation before they can replace the currently used algorithms. Existing methods for objectively comparing different insulin titration algorithms show weaknesses. In the current study, a new approach for appropriately assessing the adequacy of different algorithms is proposed. Methods Two ICU patient populations (with different baseline characteristics) were studied, both treated with a similar 'nurse-driven' insulin titration algorithm targeting BG levels of 80 to 110 mg/dl. A new method for objectively evaluating BG deviations from normoglycemia was founded on a smooth penalty function. Next, the performance of this new evaluation tool was compared with the current standard assessment methods, on an individual as well as a population basis. Finally, the impact of four selected parameters (the average BG sampling frequency, the duration of algorithm application, the severity of disease, and the type of illness) on the performance of an insulin titration algorithm was determined by multiple regression analysis. Results The glycemic penalty index (GPI) was proposed as a tool for assessing the overall glycemic control behavior in ICU patients. The GPI of a patient is the average of all penalties that are individually assigned to each measured BG value based on the optimized smooth penalty function. The computation of this index returns a number between 0 (no penalty) and 100 (the highest penalty). For some patients, the assessment of the BG control behavior using the traditional standard evaluation methods was different from the evaluation with GPI. Two parameters were found to have a significant impact on GPI: the BG sampling frequency and the duration of algorithm application. A higher BG sampling frequency and a longer algorithm application duration resulted in an apparently better performance, as indicated by a lower GPI. Conclusion The GPI is an alternative method for evaluating the performance of BG control algorithms. The blood glucose sampling frequency and the duration of algorithm application should be similar when comparing algorithms. PMID:18302732

  18. Effects of Filtering on Experimental Blast Overpressure Measurements.

    PubMed

    Alphonse, Vanessa D; Kemper, Andrew R; Duma, Stefan M

    2015-01-01

    When access to live-fire test facilities is limited, experimental studies of blast-related injuries necessitate the use of a shock tube or Advanced Blast Simulator (ABS) to mimic free-field blast overpressure. However, modeling blast overpressure in a laboratory setting potentially introduces experimental artifacts in measured responses. Due to the high sampling rates required to capture a blast overpressure event, proximity to alternating current (AC-powered electronics) and poorly strain-relieved or unshielded wires can result in artifacts in the recorded overpressure trace. Data in this study were collected for tests conducted on an empty ABS (“Empty Tube”) using high frequency pressure sensors specifically designed for blast loading rates (n=5). Additionally, intraocular overpressure data (“IOP”) were collected for porcine eyes potted inside synthetic orbits located inside the ABS using an unshielded miniature pressure sensor (n=3). All tests were conducted at a 30 psi static overpressure level. A 4th order phaseless low pass Butterworth software filter was applied to the data. Various cutoff frequencies were examined to determine if the raw shock wave parameters values could be preserved while eliminating noise and artifacts. A Fast Fourier Transform (FFT) was applied to each test to examine the frequency spectra of the raw and filtered signals. Shock wave parameters (time of arrival, peak overpressure, positive duration, and positive impulse) were quantified using a custom MATLAB® script. Lower cutoff frequencies attenuated the raw signal, effectively decreasing the peak overpressure and increasing the positive duration. Rise time was not preserved the filtered data. A CFC 6000 filter preserved the remaining shock wave parameters within ±2.5% of the average raw values for the Empty Tube test data. A CFC 7000 filter removed experimental high-frequency artifacts and preserved the remaining shock wave parameters within ±2.5% of the average raw values for test IOP test data. Though the region of interest of the signals examined in the current study did not contain extremely high frequency content, it is possible that live-fire testing may produce shock waves with higher frequency content. While post-processing filtering can remove experimental artifacts, special care should be taken to minimize or eliminate the possibility of recording these artifacts in the first place.

  19. Frequency and time properties of decimeter narrowband spikes in solar flares

    NASA Astrophysics Data System (ADS)

    Wang, Shujuan

    2013-07-01

    In this paper, we focus to study the frequency and time properties of a group of spikes recorded by the 1.08-2.04 GHz spectrometer of NAOC on 27 October 2003. At the first we calculate the mean and minimum bandwidth of the spikes. We apply two different methods based on the wavelet analysis according to Messmer & Benz (2000). The first method determines the dominant spike bandwidth scale based on their scalegram, and the second method is a feature detection algorithm in the time-frequency plane. Secondly the time profile of each single spike was fitted and analyzed. In particular, we determined the e-folding rise and decay times corresponding to the ascending and decaying parts of the time profile, respectively. Several important correlations were studied and compared with the results in earlier literature, i.e. those between duration and frequency, e-folding rise time and decay time, e-folding decay time and duration, and e-folding decay time and peak flux. Finally some parameters of source region were estimated and the possible decaying mechanism was discussed.

  20. Optimizing pulsed Nd:YAG laser beam welding process parameters to attain maximum ultimate tensile strength for thin AISI316L sheet using response surface methodology and simulated annealing algorithm

    NASA Astrophysics Data System (ADS)

    Torabi, Amir; Kolahan, Farhad

    2018-07-01

    Pulsed laser welding is a powerful technique especially suitable for joining thin sheet metals. In this study, based on experimental data, pulsed laser welding of thin AISI316L austenitic stainless steel sheet has been modeled and optimized. The experimental data required for modeling are gathered as per Central Composite Design matrix in Response Surface Methodology (RSM) with full replication of 31 runs. Ultimate Tensile Strength (UTS) is considered as the main quality measure in laser welding. Furthermore, the important process parameters including peak power, pulse duration, pulse frequency and welding speed are selected as input process parameters. The relation between input parameters and the output response is established via full quadratic response surface regression with confidence level of 95%. The adequacy of the regression model was verified using Analysis of Variance technique results. The main effects of each factor and the interactions effects with other factors were analyzed graphically in contour and surface plot. Next, to maximum joint UTS, the best combinations of parameters levels were specified using RSM. Moreover, the mathematical model is implanted into a Simulated Annealing (SA) optimization algorithm to determine the optimal values of process parameters. The results obtained by both SA and RSM optimization techniques are in good agreement. The optimal parameters settings for peak power of 1800 W, pulse duration of 4.5 ms, frequency of 4.2 Hz and welding speed of 0.5 mm/s would result in a welded joint with 96% of the base metal UTS. Computational results clearly demonstrate that the proposed modeling and optimization procedures perform quite well for pulsed laser welding process.

  1. Effects of Bounded Fault on Seismic Radiation and Rupture Propagation

    NASA Astrophysics Data System (ADS)

    Weng, H.; Yang, H.

    2016-12-01

    It has been suggested that narrow rectangle fault may emit stopping phases that can largely affect seismic radiation and thus rupture propagation, e.g., generation of short-duration pulse-like ruptures. Here we investigate the effects of narrow along-dip rectangle fault (analogously to 2015 Nepal earthquake with 200 km * 40 km) on seismic radiation and rupture propagation through numerical modeling in the framework of the linear slip-weakening friction law. First, we found the critical slip-weakening distance Dc may largely affect the seismic radiation and other source parameters, such as rupture speed, final slip and stress drop. Fixing all other uniform parameters, decreasing Dc could decrease the duration time of slip rate and increase the peak slip rate, thus increase the seismic radiation energy spectrum of slip acceleration. In addition, smaller Dc could lead to larger rupture speed (close to S wave velocity), but smaller stress drop and final slip. The results show that Dc may control the efficiency of far-field radiation. Furthermore, the duration time of slip rate at locations close to boundaries is 1.5 - 4 s less than that in the center of the fault. Such boundary effect is especially remarkable for smaller Dc due to the smaller average duration time of slip rate, which could increase the high-frequency radiation energy and impede low-frequency component near the boundaries from the analysis of energy spectrum of slip acceleration. These results show high frequency energy tends to be radiated near the fault boundaries as long as Dc is small enough. In addition, ruptures are fragile and easy to self-arrest if the width of the seismogenic zone is very narrow. In other words, the sizes of nucleation zone need to be larger to initiate runaway ruptures. Our results show the critical sizes of nucleation zones increase as the widths of seismogenic zones decrease.

  2. Source Parameters and Rupture Directivities of Earthquakes Within the Mendocino Triple Junction

    NASA Astrophysics Data System (ADS)

    Allen, A. A.; Chen, X.

    2017-12-01

    The Mendocino Triple Junction (MTJ), a region in the Cascadia subduction zone, produces a sizable amount of earthquakes each year. Direct observations of the rupture properties are difficult to achieve due to the small magnitudes of most of these earthquakes and lack of offshore observations. The Cascadia Initiative (CI) project provides opportunities to look at the earthquakes in detail. Here we look at the transform plate boundary fault located in the MTJ, and measure source parameters of Mw≥4 earthquakes from both time-domain deconvolution and spectral analysis using empirical Green's function (EGF) method. The second-moment method is used to infer rupture length, width, and rupture velocity from apparent source duration measured at different stations. Brune's source model is used to infer corner frequency and spectral complexity for stacked spectral ratio. EGFs are selected based on their location relative to the mainshock, as well as the magnitude difference compared to the mainshock. For the transform fault, we first look at the largest earthquake recorded during the Year 4 CI array, a Mw5.72 event that occurred in January of 2015, and select two EGFs, a Mw1.75 and a Mw1.73 located within 5 km of the mainshock. This earthquake is characterized with at least two sub-events, with total duration of about 0.3 second and rupture length of about 2.78 km. The earthquake is rupturing towards west along the transform fault, and both source durations and corner frequencies show strong azimuthal variations, with anti-correlation between duration and corner frequency. The stacked spectral ratio from multiple stations with the Mw1.73 EGF event shows deviation from pure Brune's source model following the definition from Uchide and Imanishi [2016], likely due to near-field recordings with rupture complexity. We will further analyze this earthquake using more EGF events to test the reliability and stability of the results, and further analyze three other Mw≥4 earthquakes within the array.

  3. Achieving Optimal Quantum Acceleration of Frequency Estimation Using Adaptive Coherent Control.

    PubMed

    Naghiloo, M; Jordan, A N; Murch, K W

    2017-11-03

    Precision measurements of frequency are critical to accurate time keeping and are fundamentally limited by quantum measurement uncertainties. While for time-independent quantum Hamiltonians the uncertainty of any parameter scales at best as 1/T, where T is the duration of the experiment, recent theoretical works have predicted that explicitly time-dependent Hamiltonians can yield a 1/T^{2} scaling of the uncertainty for an oscillation frequency. This quantum acceleration in precision requires coherent control, which is generally adaptive. We experimentally realize this quantum improvement in frequency sensitivity with superconducting circuits, using a single transmon qubit. With optimal control pulses, the theoretically ideal frequency precision scaling is reached for times shorter than the decoherence time. This result demonstrates a fundamental quantum advantage for frequency estimation.

  4. Uncooled Infrared Microbolometers and Silicon Germanium Oxide (SixGe1-xOy) Infrared Sensitive Material for Long Wavelength Detection

    DTIC Science & Technology

    2014-10-10

    Hooge ’s parameters and 1/f noise at the comer frequency for the four wafers are shown in Table 6. We see in the table that the average value of ywas...voltage noise power spectral densities were analyzed and Hooge’s parameters were determined. UNCOOLED MICROBOLOMETER A thermal detector exhibits a...annealing at 200 °C, 250 °C, and 300 °C for duration from 1 hour to 5 hours using a bias current of 0.07 µA. The corresponding Hooge’s parameters for

  5. [Brain Mechanisms for Measuring Time: Population Coding of Durations].

    PubMed

    Hayashi, Masamichi J

    2016-11-01

    Temporal processing is crucial in many aspects of our perception and action. While there is mounting evidence for the encoding mechanisms of spatial ("where") and identity ("what") information, those of temporal information ("when") remain largely unknown. Recent studies suggested that, similarly to the basic visual stimulus features such as orientation, motion direction, and numerical quantity, event durations are also represented by a population of neurons that are tuned for specific, preferred durations. This paper first reviews recent psychophysical studies on duration aftereffect. Changes in the three parameters (response gain, shift, and width of tuning curves) are then discussed that may need to be taken into account in the putative duration-channel model. Next, the potential neural basis of the duration channels is examined by overviewing recent neuroimaging and electrophysiological studies on time perception. Finally, this paper proposes a general neural basis of timing that commonly represents time-differences independent of stimulus types (e.g., a single duration v.s. multiple brief events). This extends the idea of the "when pathway" from the perception of temporal order to the general timing mechanisms for the perception of duration, temporal frequency, and synchrony.

  6. Describing Treatment Intensity in Milieu Teaching Interventions for Children with Developmental Disabilities: A Review

    ERIC Educational Resources Information Center

    Parker-McGowan, Quannah; Chen, Mo; Reichle, Joe; Pandit, Shivani; Johnson, LeAnne; Kreibich, Shelley

    2014-01-01

    Purpose: This investigation aimed to apply the dosage framework proposed by Warren, Fey, and Yoder (2007) to variations of milieu language teaching intervention strategies to explore how each of the dosage parameters (i.e., dose, dose form, dose frequency, total duration, and cumulative intervention intensity) was reported in the located…

  7. Automatic EEG spike detection.

    PubMed

    Harner, Richard

    2009-10-01

    Since the 1970s advances in science and technology during each succeeding decade have renewed the expectation of efficient, reliable automatic epileptiform spike detection (AESD). But even when reinforced with better, faster tools, clinically reliable unsupervised spike detection remains beyond our reach. Expert-selected spike parameters were the first and still most widely used for AESD. Thresholds for amplitude, duration, sharpness, rise-time, fall-time, after-coming slow waves, background frequency, and more have been used. It is still unclear which of these wave parameters are essential, beyond peak-peak amplitude and duration. Wavelet parameters are very appropriate to AESD but need to be combined with other parameters to achieve desired levels of spike detection efficiency. Artificial Neural Network (ANN) and expert-system methods may have reached peak efficiency. Support Vector Machine (SVM) technology focuses on outliers rather than centroids of spike and nonspike data clusters and should improve AESD efficiency. An exemplary spike/nonspike database is suggested as a tool for assessing parameters and methods for AESD and is available in CSV or Matlab formats from the author at brainvue@gmail.com. Exploratory Data Analysis (EDA) is presented as a graphic method for finding better spike parameters and for the step-wise evaluation of the spike detection process.

  8. Interdependent effects of sound duration and amplitude on neuronal onset response in mice inferior colliculus.

    PubMed

    Wang, Ningqian; Wang, Xiao; Yang, Xiaoli; Tang, Jie; Xiao, Zhongju

    2014-01-16

    In this study, we adopted iso-frequency pure tone bursts to investigate the interdependent effects of sound amplitude/intensity and duration on mice inferior colliculus (IC) neuronal onset responses. On the majority of the sampled neurons (n=57, 89.1%), sound amplitude and duration had effects on the neuronal response to each other by showing complex changes of the rat-intensity function/duration selectivity types and/or best amplitudes (BAs)/durations (BDs), evaluated by spike counts. These results suggested that the balance between the excitatory and inhibitory inputs set by one acoustic parameter, amplitude or duration, affected the neuronal spike counts responses to the other. Neuronal duration selectivity types were altered easily by the low-amplitude sounds while the changes of rate-intensity function types had no obvious preferred stimulus durations. However, the first spike latencies (FSLs) of the onset response neurons were relative stable to iso-amplitude sound durations and changing systematically along with the sound levels. The superimposition of FSL and duration threshold (DT) as a function of stimulus amplitude after normalization indicated that the effects of the sound levels on FSLs are considered on DT actually. © 2013 Published by Elsevier B.V.

  9. The frequency-domain method of calculation for the pulsed electromagnetic field in a conductive ferromagnetic plate

    NASA Astrophysics Data System (ADS)

    Nosov, G. V.; Kuleshova, E. O.; Lefebvre, S.; Plyusnin, A. A.; Tokmashev, D. M.

    2017-02-01

    The technique for parameters determination of magnetic skin effect on ferromagnetic plate at a specified pulse of magnetic field intensity on the plate surface is proposed. It is based on a frequency-domain method and could be applied for a pulsing transformer, a dynamoelectric pulse generator and a commutating inductor that contains an imbricated core. Due to this technique, such plate parameters as specific heat loss energy, the average power of this energy and the plate temperature raise, the magnetic flux attenuation factor and the plate q-factor could be calculated. These parameters depend on the steel type, the amplitude, the rms value, the duration and the form of the magnetic field intensity impulse on the plate surface. The plate thickness is defined by the value of the flux attenuation factor and the plate q-factor that should be maximal. The reliability of the proposed technique is built on a common frequency-domain usage applicable for pulse transient study under zero boundary conditions of the electric circuit and the conformity of obtained results with the sinusoidal steady-state mode.

  10. Derivation of flood frequency curves in poorly gauged Mediterranean catchments using a simple stochastic hydrological rainfall-runoff model

    NASA Astrophysics Data System (ADS)

    Aronica, G. T.; Candela, A.

    2007-12-01

    SummaryIn this paper a Monte Carlo procedure for deriving frequency distributions of peak flows using a semi-distributed stochastic rainfall-runoff model is presented. The rainfall-runoff model here used is very simple one, with a limited number of parameters and practically does not require any calibration, resulting in a robust tool for those catchments which are partially or poorly gauged. The procedure is based on three modules: a stochastic rainfall generator module, a hydrologic loss module and a flood routing module. In the rainfall generator module the rainfall storm, i.e. the maximum rainfall depth for a fixed duration, is assumed to follow the two components extreme value (TCEV) distribution whose parameters have been estimated at regional scale for Sicily. The catchment response has been modelled by using the Soil Conservation Service-Curve Number (SCS-CN) method, in a semi-distributed form, for the transformation of total rainfall to effective rainfall and simple form of IUH for the flood routing. Here, SCS-CN method is implemented in probabilistic form with respect to prior-to-storm conditions, allowing to relax the classical iso-frequency assumption between rainfall and peak flow. The procedure is tested on six practical case studies where synthetic FFC (flood frequency curve) were obtained starting from model variables distributions by simulating 5000 flood events combining 5000 values of total rainfall depth for the storm duration and AMC (antecedent moisture conditions) conditions. The application of this procedure showed how Monte Carlo simulation technique can reproduce the observed flood frequency curves with reasonable accuracy over a wide range of return periods using a simple and parsimonious approach, limited data input and without any calibration of the rainfall-runoff model.

  11. Multimodal gain control at the hippocampal Schaffer collateral-CA1 synapse.

    PubMed

    Lange-Asschenfeldt, Christian; Schipke, Carola G; Riepe, Matthias W

    2007-04-06

    Information processing at central nervous system synapses is shaped by long-lasting modifications, such as long-term potentiation and short-lived and putatively synapse-specific modifications by various forms of short-term plasticity, such as facilitation, potentiation, and depression. Using an extracellular paired-pulse facilitation (PPF) protocol at the Schaffer collateral-CA1 (SC) connection in acute hippocampal slices in mice, we extend previous reports of optimal signal gain at intermediate interpulse intervals obtained at single SC synapses to the network level. Moreover, maximum signal gain changed when the input intensity was altered. We found further that facilitation decreased with increasing stimulus amplitude and duration in an exact exponential fashion when varied at a fixed interpulse interval. Variation of these intensity parameters accounted for significant changes in PPF adding a spatial dimension to time-based synaptic filter characteristics. Thus, this synapse functions as an amplitude window discriminator with a low-level aperture in combination with a band-pass frequency filter. By providing mathematical functions for the characteristic presynaptic parameters frequency, stimulus amplitude, and pulse duration at the network level our results lay ground for future studies on pharmacologically, genetically, or otherwise altered animal models.

  12. Constraints on the source parameters of low-frequency earthquakes on the San Andreas Fault

    USGS Publications Warehouse

    Thomas, Amanda M.; Beroza, Gregory C.; Shelly, David R.

    2016-01-01

    Low-frequency earthquakes (LFEs) are small repeating earthquakes that occur in conjunction with deep slow slip. Like typical earthquakes, LFEs are thought to represent shear slip on crustal faults, but when compared to earthquakes of the same magnitude, LFEs are depleted in high-frequency content and have lower corner frequencies, implying longer duration. Here we exploit this difference to estimate the duration of LFEs on the deep San Andreas Fault (SAF). We find that the M ~ 1 LFEs have typical durations of ~0.2 s. Using the annual slip rate of the deep SAF and the average number of LFEs per year, we estimate average LFE slip rates of ~0.24 mm/s. When combined with the LFE magnitude, this number implies a stress drop of ~104 Pa, 2 to 3 orders of magnitude lower than ordinary earthquakes, and a rupture velocity of 0.7 km/s, 20% of the shear wave speed. Typical earthquakes are thought to have rupture velocities of ~80–90% of the shear wave speed. Together, the slow rupture velocity, low stress drops, and slow slip velocity explain why LFEs are depleted in high-frequency content relative to ordinary earthquakes and suggest that LFE sources represent areas capable of relatively higher slip speed in deep fault zones. Additionally, changes in rheology may not be required to explain both LFEs and slow slip; the same process that governs the slip speed during slow earthquakes may also limit the rupture velocity of LFEs.

  13. Analytical flow duration curves for summer streamflow in Switzerland

    NASA Astrophysics Data System (ADS)

    Santos, Ana Clara; Portela, Maria Manuela; Rinaldo, Andrea; Schaefli, Bettina

    2018-04-01

    This paper proposes a systematic assessment of the performance of an analytical modeling framework for streamflow probability distributions for a set of 25 Swiss catchments. These catchments show a wide range of hydroclimatic regimes, including namely snow-influenced streamflows. The model parameters are calculated from a spatially averaged gridded daily precipitation data set and from observed daily discharge time series, both in a forward estimation mode (direct parameter calculation from observed data) and in an inverse estimation mode (maximum likelihood estimation). The performance of the linear and the nonlinear model versions is assessed in terms of reproducing observed flow duration curves and their natural variability. Overall, the nonlinear model version outperforms the linear model for all regimes, but the linear model shows a notable performance increase with catchment elevation. More importantly, the obtained results demonstrate that the analytical model performs well for summer discharge for all analyzed streamflow regimes, ranging from rainfall-driven regimes with summer low flow to snow and glacier regimes with summer high flow. These results suggest that the model's encoding of discharge-generating events based on stochastic soil moisture dynamics is more flexible than previously thought. As shown in this paper, the presence of snowmelt or ice melt is accommodated by a relative increase in the discharge-generating frequency, a key parameter of the model. Explicit quantification of this frequency increase as a function of mean catchment meteorological conditions is left for future research.

  14. Properties of Langmuir wave bursts associated with magnetic holes

    NASA Technical Reports Server (NTRS)

    MacDowall, R. J.; Lin, N.; Kellogg, P. J.; Phillips, J. L.; Neugebauer, M.; Balogh, A.; Forsyth, R. J.

    1995-01-01

    The radio and plasma wave receivers on the Ulysses spacecraft have detected thousands of short-duration bursts of waves at approximately the electron plasma frequency. These wave events believed to be Langmuir waves are usually less than approximately 5 minutes in duration. They occur in or at the boundaries of depletions in the magnetic field amplitude known as magnetic holes. Using the 16 sec time resolution provided by the plasma frequency receiver, it is possible to examine the density structure inside of magnetic holes. Even higher time resolutions are sometimes available from the radio receiver data. The Ulysses observations show that these wave bursts occur more frequently at high heliographic latitudes; the occurrence rates depend on both latitude and distance from the Sun. We review the statistics for the wave events, compare them to magnetic and plasma parameters, and review the reasons for the more frequent occurrence at high heliographic latitudes.

  15. Passively Q-switched, intracavity frequency-doubled YVO{sub 4}/Nd : YVO{sub 4}/KTP green laser with a GaAs saturable absorber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shang Gao

    2015-11-30

    A diode-pumped, passively Q-switched, intracavity frequency-doubled YVO{sub 4}/Nd : YVO{sub 4}/KTP green laser is realised using a GaAs saturable absorber. Two pieces of GaAs wafers are employed in the experiment. In using a 400-μm-thick GaAs wafer and an incident pump power of 10.5 W, the maximum output power of the passively Q-switched green laser is 362 mW at a pulse repetition rate of 84 kHz and a pulse duration of 2.5 ns. When use is made of a 700-mm-thick GaAs wafer, the minimum pulse duration is 1.5 ns at a repetition rate of 67 kHz, pulse energy of 4.18 μJmore » and peak power of 2.8 kW. (control of laser radiation parameters)« less

  16. Time distortion associated with smartphone addiction: Identifying smartphone addiction via a mobile application (App).

    PubMed

    Lin, Yu-Hsuan; Lin, Yu-Cheng; Lee, Yang-Han; Lin, Po-Hsien; Lin, Sheng-Hsuan; Chang, Li-Ren; Tseng, Hsien-Wei; Yen, Liang-Yu; Yang, Cheryl C H; Kuo, Terry B J

    2015-06-01

    Global smartphone penetration has brought about unprecedented addictive behaviors. We report a proposed diagnostic criteria and the designing of a mobile application (App) to identify smartphone addiction. We used a novel empirical mode decomposition (EMD) to delineate the trend in smartphone use over one month. The daily use count and the trend of this frequency are associated with smartphone addiction. We quantify excessive use by daily use duration and frequency, as well as the relationship between the tolerance symptoms and the trend for the median duration of a use epoch. The psychiatrists' assisted self-reporting use time is significant lower than and the recorded total smartphone use time via the App and the degree of underestimation was positively correlated with actual smartphone use. Our study suggests the identification of smartphone addiction by diagnostic interview and via the App-generated parameters with EMD analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Psychiatric Disorders, High-Risk Behaviors, and Chronicity of Episodes Among Predominantly African American Homeless Chicago Youth

    PubMed Central

    Castro, Anne L.; Gustafson, Erika L.; Ford, Ashley E.; Edidin, Jennifer P.; Smith, Dale L.; Hunter, Scott J.; Karnik, Niranjan S.

    2014-01-01

    Objective This cross-sectional study investigated the relationships between psychiatric and substance-related disorders, high-risk behaviors, and the onset, duration, and frequency of homelessness among homeless youth in Chicago. Methods Sixty-six homeless youth were recruited from two shelters in Chicago. Demographic characteristics, psychopathology, substance use, and risk behaviors were assessed for each participant. Results Increased frequency and duration of homeless episodes were positively correlated with higher rates of psychiatric diagnoses. Increased number of psychiatric diagnoses was positively correlated with increased high-risk behaviors. Participants with diagnoses of Current Suicidality, Manic Episodes, Obsessive Compulsive Disorder, Substance Abuse, and Psychotic Disorder had a higher chronicity of homelessness than those without diagnoses. Conclusions Significant differences were evident between the three time parameters, suggesting that stratification of data by different time variables may benefit homelessness research by identifying meaningful subgroups who may benefit from individualized interventions. PMID:25130234

  18. Periodontal disease and type 1 diabetes mellitus: associations with glycemic control and complications: an Indian perspective.

    PubMed

    Ajita, Meenawat; Karan, Punn; Vivek, Govila; S, Meenawat Anand; Anuj, Maheshwari

    2013-01-01

    To evaluate the frequency of periodontal disease in a group of patients with type 1 diabetes mellitus and its relationship with diabetic metabolic control, duration and complications. A comparison was made of periodontal parameters (plaque index, bleeding index, pocket depth and attachment loss) in a group of diabetic patients versus a group of non-diabetics (n=20). Statistical analysis was performed to evaluate the relationship between periodontal parameters and degree of metabolic control, the duration of the disease and the appearance of complications. Diabetics had greater bleeding index (p<0.001), probing pocket depth (p<0.001) and clinical attachment level (p=0.001). Patients diagnosed for diabetes for shorter duration of time (4-7 years) showed bleeding index-disease severity correlation to be 1.760 ± 0.434. Patients with type 1 diabetes have increased periodontal disease susceptibility. Periodontal inflammation is greatly increased in subjects with longer disease course, poor metabolic control and diabetic complications. Copyright © 2013 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  19. The use of heart rate turbulence and heart rate variability in the assessment of autonomic regulation and circadian rhythm in patients with systemic lupus erythematosus without apparent heart disease.

    PubMed

    Poliwczak, A R; Waszczykowska, E; Dziankowska-Bartkowiak, B; Koziróg, M; Dworniak, K

    2018-03-01

    Background Systemic lupus erythematosus is a progressive autoimmune disease. There are reports suggesting that patients even without overt signs of cardiovascular complications have impaired autonomic function. The aim of this study was to assess autonomic function using heart rate turbulence and heart rate variability parameters indicated in 24-hour ECG Holter monitoring. Methods Twenty-six women with systemic lupus erythematosus and 30 healthy women were included. Twenty-four hour ambulatory ECG-Holter was performed in home conditions. The basic parameters of heart rate turbulence and heart rate variability were calculated. The analyses were performed for the entire day and separately for daytime activity and night time rest. Results There were no statistically significant differences in the basic anthropometric parameters. The mean duration of disease was 11.52 ± 7.42. There was a statistically significant higher turbulence onset (To) value in patients with systemic lupus erythematosus, median To = -0.17% (minimum -1.47, maximum 3.0) versus To = -1.36% (minimum -4.53, maximum -0.41), P < 0.001. There were no such differences for turbulence slope (Ts). In the 24-hour analysis almost all heart rate variability parameters were significantly lower in the systemic lupus erythematosus group than in the healthy controls, including SDANN and r-MSSD and p50NN. Concerning the morning activity and night resting periods, the results were similar as for the whole day. In the control group, higher values in morning activity were noted for parameters that characterise sympathetic activity, especially SDANN, and were significantly lower for parasympathetic parameters, including r-MSSD and p50NN, which prevailed at night. There were no statistically significant changes for systemic lupus erythematosus patients for p50NN and low and very low frequency. There was a positive correlation between disease duration and SDNN, R = 0.417; P < 0.05 and SDANN, R = 0.464; P < 0.05, a negative correlation between low/high frequency ratio and r-MSSD, R = -0.454; P < 0.05; p50NN, R = -0.435; P < 0.05 and high frequency, R = -0.478; P < 0.05. In contrast, there was no statistically significant correlation between heart rate turbulence and other variables evaluated, including disease duration and the type of autoantibodies. Our study confirms the presence of autonomic disorders with respect to both heart rate variability and heart rate turbulence parameters and the presence of diurnal disturbances of sympathetic-parasympathetic balance. Further studies are required.

  20. Spectral Investigation of Large and Medium Scale Traveling Ionospheric Disturbances using GPS Slant Total Electron Content

    NASA Astrophysics Data System (ADS)

    Yarici, Aysenur; Arikan, Feza; Efendi, Emre

    2016-07-01

    Global Positioning System (GPS) provides opportunity to study the ionospheric variability as the navigation and positions signals transverse ionosphere on their path to ground based dual frequency receivers. Slant Total Electron Content (STEC) is defined as the line integral of electron density along a ray path that connect GPS receiver to satellite. Due to the inhomogeneous, anisotropic, temporally and spatially varying nature of ionosphere, GPS signals that are passing through the ionosphere are affected and this situation can be observed as disturbance on STEC data. Traveling Ionospheric Disturbances (TIDs) are irregularities of the ionosphere expressed as wave-like oscillations decrescent slowly through time. TIDs are classified into two types according to their wave parameters such as velocity, period and wavelength as large and medium scale. In this study, a new method, namely Ionospheric-Fast Fourier Transform (I-FFT), is developed to investigate the spectral properties of TIDs. I-FFT is applied to STEC data after the TID is detected using the Differential Rate of TEC (DRoT) method developed by IONOLAB group. The performance of the developed I-FFT method is evaluated over the synthetic data to obtain the bounds on the estimation error. It is observed that I-FFT method can estimate the frequency and duration of TIDs with 80% or more accuracy. In the application of I-FFT to various GPS-STEC data from stations located at high, equatorial and mid-latitude regions for detection of frequency and duration of TIDs due to geomagnetic storms and seismic activities, it is observed that TIDs with frequencies between 0.6 mHz to 2.4 mHz and durations longer than 10 minutes; and TIDs with frequencies between 0.15 mHz to 0.6 mHz and durations longer than 75 minutes can be estimated automatically with more than 80% accuracy. This study is supported by TUBITAK EEEAG 115E915 project.

  1. Changes in vocal parameters with social context in humpback whales: considering the effect of bystanders.

    PubMed

    Dunlop, Rebecca A

    Many theories and communication models developed from terrestrial studies focus on a simple dyadic exchange between a sender and receiver. During social interactions, the "frequency code" hypothesis suggests that frequency characteristics of vocal signals can simultaneously encode for static signaler attributes (size or sex) and dynamic information, such as motivation or emotional state. However, the additional presence of a bystander may result in a change of signaling behavior if the costs and benefits associated with the presence of this bystander are different from that of a simple dyad. In this study, two common humpback whale social calls ("wops" and "grumbles") were tested for differences related to group social behavior and the presence of bystanders. "Wop" parameters were stable with group social behavior, but were emitted at lower (14 dB) levels in the presence of a nearby singing whale compared to when a singing whale was not in the area. "Grumbles" were emitted at lower (30-39 Hz) fundamental frequencies in affiliative compared to non-affiliative groups and, in the presence of a nearby singing whale, were also emitted at lower (14 dB) levels. Vocal rates did not significantly change. The results suggest that, in humpbacks, the frequency in certain sound types relates to the social behavior of the vocalizing group, implying a frequency code system. The presence of a nearby audible bystander (a singing whale) had no effect on this frequency code, but by reducing their acoustic level, the signal-to-noise ratio at the singer would have been below 0, making it difficult for the singer to audibly detect the group. The frequency, duration, and amplitude parameters of humpback whale social vocalizations were tested between different social contexts: group social behavior (affiliating versus non-affiliating), the presence of a nearby singing whale, and the presence of a nearby non-singing group. "Grumbles" (commonly heard low-frequency unmodulated sounds) frequencies were lower in affiliating groups compared to non-affiliating groups, suggesting a change in group motivation (such as levels of aggression). "Wop" (another common sound type) structure (frequency and duration) was similar in affiliating and non-affiliating groups. In the presence of an audible bystander (a singing whale), both sound types were emitted at similar rates, but much lower amplitudes (14 dB), vastly reducing the detectability of these sounds by the singer. This suggests that these groups were acoustically avoiding the singing whale. They did not, however, acoustically respond to the presence of a nearby non-singing group.

  2. Effects of past and present livestock grazing on herpetofauna in a landscape-scale experiment.

    PubMed

    Kay, Geoffrey M; Mortelliti, Alessio; Tulloch, Ayesha; Barton, Philip; Florance, Daniel; Cunningham, Saul A; Lindenmayer, David B

    2017-04-01

    Livestock grazing is the most widespread land use on Earth and can have negative effects on biodiversity. Yet, many of the mechanisms by which grazing leads to changes in biodiversity remain unresolved. One reason is that conventional grazing studies often target broad treatments rather than specific parameters of grazing (e.g., intensity, duration, and frequency) or fail to account for historical grazing effects. We conducted a landscape-scale replicated grazing experiment (15,000 km 2 , 97 sites) to examine the impact of past grazing management and current grazing regimes (intensity, duration, and frequency) on a community of ground-dwelling herpetofauna (39 species). We analyzed community variables (species richness and composition) for all species and built multiseason patch-occupancy models to predict local colonization and extinction for the 7 most abundant species. Past grazing practices did not influence community richness but did affect community composition and patch colonization and extinction for 4 of 7 species. Present grazing parameters did not influence community richness or composition, but 6 of the 7 target species were affected by at least one grazing parameter. Grazing frequency had the most consistent influence, positively affecting 3 of 7 species (increased colonization or decreased extinction). Past grazing practice affected community composition and population dynamics in some species in different ways, which suggests that conservation planners should examine the different grazing histories of an area. Species responded differently to specific current grazing practices; thus, incentive programs that apply a diversity of approaches rather than focusing on a change such as reduced grazing intensity should be considered. Based on our findings, we suggest that determining fine-scale grazing attributes is essential for advancing grazing as a conservation strategy. © 2016 Society for Conservation Biology.

  3. [The action of low-intensity extremely high-freguency electromagnetic radiation on growth parameters for bacteria Enterococcus hirae].

    PubMed

    Oganian, V; Sarkisian, A; Tadevosian, A; Torchunian, A

    2008-01-01

    It has been found that the exposure of Enterococcus hirae ATCC9790, grown under anaerobic conditions for 30 min or 1 h, to low-intensity (flux capacity 0.06 mW/sm2) coherent electromagnetic radiation (EMI) of extremely high-frequency 45 - 53 GHz), or millimeter waves causes a marked prolongation of the lag-growth phase and a decrease in their specific growth rate, the inhibitory effect increasing in the frequency range from 49 to 53 GHz. The effect enhanced as duration of expocure was encreased from 30 min to 1 h; however, further increase in exposure duration to 2 h did not cause an enhancement of the effect. It has been shown that the action of extremely high-frequency EMI on these bacteria does not depend on medium pH (pH 8.0 or pH 6.0). It is proposed that these bacteria have defensive or reparation mechanisms which compensate for the action of radiation; the occurrence of different mechanisms for pH regulation is not ruled out.

  4. Count distribution for mixture of two exponentials as renewal process duration with applications

    NASA Astrophysics Data System (ADS)

    Low, Yeh Ching; Ong, Seng Huat

    2016-06-01

    A count distribution is presented by considering a renewal process where the distribution of the duration is a finite mixture of exponential distributions. This distribution is able to model over dispersion, a feature often found in observed count data. The computation of the probabilities and renewal function (expected number of renewals) are examined. Parameter estimation by the method of maximum likelihood is considered with applications of the count distribution to real frequency count data exhibiting over dispersion. It is shown that the mixture of exponentials count distribution fits over dispersed data better than the Poisson process and serves as an alternative to the gamma count distribution.

  5. Kilohertz and Low-Frequency Electrical Stimulation With the Same Pulse Duration Have Similar Efficiency for Inducing Isometric Knee Extension Torque and Discomfort.

    PubMed

    Medeiros, Flávia Vanessa; Bottaro, Martim; Vieira, Amilton; Lucas, Tiago Pires; Modesto, Karenina Arrais; Bo, Antonio Padilha L; Cipriano, Gerson; Babault, Nicolas; Durigan, João Luiz Quagliotti

    2017-06-01

    To test the hypotheses that, as compared with pulsed current with the same pulse duration, kilohertz frequency alternating current would not differ in terms of evoked-torque production and perceived discomfort, and as a result, it would show the same current efficiency. A repeated-measures design with 4 stimuli presented in random order was used to test 25 women: (1) 500-microsecond pulse duration, (2) 250-microsecond pulse duration, (3) 500-microsecond pulse duration and low carrier frequency (1 kHz), (4) 250-microsecond pulse duration and high carrier frequency (4 kHz). Isometric peak torque of quadriceps muscle was measured using an isokinetic dynamometer. Discomfort was measured using a visual analog scale. Currents with long pulse durations induced approximately 21% higher evoked torque than short pulse durations. In addition, currents with 500 microseconds delivered greater amounts of charge than stimulation patterns using 250-microsecond pulse durations (P < 0.05). All currents presented similar discomfort. There was no difference on stimulation efficiency with the same pulse duration. Both kilohertz frequency alternating current and pulsed current, with the same pulse duration, have similar efficiency for inducing isometric knee extension torque and discomfort. However, neuromuscular electrical stimulation (NMES) with longer pulse duration induces higher NMES-evoked torque, regardless of the carrier frequency. Pulse duration is an important variable that should receive more attention for an optimal application of NMES in clinical settings.

  6. Continuous Sub-daily Rainfall Simulation for Regional Flood Risk Assessment - Modelling of Spatio-temporal Correlation Structure of Extreme Precipitation in the Austrian Alps

    NASA Astrophysics Data System (ADS)

    Salinas, J. L.; Nester, T.; Komma, J.; Bloeschl, G.

    2017-12-01

    Generation of realistic synthetic spatial rainfall is of pivotal importance for assessing regional hydroclimatic hazard as the input for long term rainfall-runoff simulations. The correct reproduction of observed rainfall characteristics, such as regional intensity-duration-frequency curves, and spatial and temporal correlations is necessary to adequately model the magnitude and frequency of the flood peaks, by reproducing antecedent soil moisture conditions before extreme rainfall events, and joint probability of flood waves at confluences. In this work, a modification of the model presented by Bardossy and Platte (1992), where precipitation is first modeled on a station basis as a multivariate autoregressive model (mAr) in a Normal space. The spatial and temporal correlation structures are imposed in the Normal space, allowing for a different temporal autocorrelation parameter for each station, and simultaneously ensuring the positive-definiteness of the correlation matrix of the mAr errors. The Normal rainfall is then transformed to a Gamma-distributed space, with parameters varying monthly according to a sinusoidal function, in order to adapt to the observed rainfall seasonality. One of the main differences with the original model is the simulation time-step, reduced from 24h to 6h. Due to a larger availability of daily rainfall data, as opposite to sub-daily (e.g. hourly), the parameters of the Gamma distributions are calibrated to reproduce simultaneously a series of daily rainfall characteristics (mean daily rainfall, standard deviations of daily rainfall, and 24h intensity-duration-frequency [IDF] curves), as well as other aggregated rainfall measures (mean annual rainfall, and monthly rainfall). The calibration of the spatial and temporal correlation parameters is performed in a way that the catchment-averaged IDF curves aggregated at different temporal scales fit the measured ones. The rainfall model is used to generate 10.000 years of synthetic precipitation, fed into a rainfall-runoff model to derive the flood frequency in the Tirolean Alps in Austria. Given the number of generated events, the simulation framework is able to generate a large variety of rainfall patterns, as well as reproduce the variograms of relevant extreme rainfall events in the region of interest.

  7. Focused ultrasound-mediated noninvasive blood-brain barrier modulation: preclinical examination of efficacy and safety in various sonication parameters.

    PubMed

    Shin, Jaewoo; Kong, Chanho; Cho, Jae Sung; Lee, Jihyeon; Koh, Chin Su; Yoon, Min-Sik; Na, Young Cheol; Chang, Won Seok; Chang, Jin Woo

    2018-02-01

    OBJECTIVE The application of pharmacological therapeutics in neurological disorders is limited by the ability of these agents to penetrate the blood-brain barrier (BBB). Focused ultrasound (FUS) has recently gained attention for its potential application as a method for locally opening the BBB and thereby facilitating drug delivery into the brain parenchyma. However, this method still requires optimization to maximize its safety and efficacy for clinical use. In the present study, the authors examined several sonication parameters of FUS influencing BBB opening in small animals. METHODS Changes in BBB permeability were observed during transcranial sonication using low-intensity FUS in 20 adult male Sprague-Dawley rats. The authors examined the effects of FUS sonication with different sonication parameters, varying acoustic pressure, center frequency, burst duration, microbubble (MB) type, MB dose, pulse repetition frequency (PRF), and total exposure time. The focal region of BBB opening was identified by Evans blue dye. Additionally, H & E staining was used to identify blood vessel damage. RESULTS Acoustic pressure amplitude and burst duration were closely associated with enhancement of BBB opening efficiency, but these parameters were also highly correlated with tissue damage in the sonicated region. In contrast, MB types, MB dose, total exposure time, and PRF had an influence on BBB opening without conspicuous tissue damage after FUS sonication. CONCLUSIONS The study aimed to identify these influential conditions and provide safety and efficacy values for further studies. Future work based on the current results is anticipated to facilitate the implementation of FUS sonication for drug delivery in various CNS disease states in the near future.

  8. Quantified activity pattern data from 6 to 27-month-old farmworker children for use in exposure assessment.

    PubMed

    Beamer, Paloma; Key, Maya E; Ferguson, Alesia C; Canales, Robert A; Auyeung, Willa; Leckie, James O

    2008-10-01

    This study was conducted to describe exposure prone behaviors of infants and toddlers in the farmworker community. Analysis of hand and mouth contact frequencies and durations aids understanding of how children interact with their environment and are exposed via contact with surfaces. All 23 participating children (8 female infants, 5 male infants, 5 female toddlers and 5 male toddlers) lived with at least one farmworker. Children were videotaped at home for 2-6 h. Video footage was translated into micro-level activity time series (MLATS) for both hands and the mouth. MLATS were processed to calculate hourly duration in microenvironments, contact frequency, hourly contact duration and median contact duration. The median hourly duration spent indoors was 53 min/h. The median hand-to-mouth frequency was 15.2 events/h and the median object-to-mouth frequency was 27.2 events/h. The hourly mouthing duration was 1.2 and 2.2 min/h with the hands and objects, respectively. The median mouthing duration with hands and objects was 2 s. The median contact frequency for both hands combined was 689.4 events/h with an hourly contact duration of 100.5 min/h and a median contact duration of 3s. Infants had higher mouthing frequencies with non-dietary objects while toddlers had higher mouthing frequencies with objects associated with pica (i.e., paper). Boys had higher contact frequencies while girls had longer contact durations. These sub-group differences indicate factors such as age and gender should be accounted for when conducting exposure assessments. Contact frequencies in this study are higher than current US EPA recommendations, questioning their protective value for infants and toddlers.

  9. Quantified Activity Pattern Data from 6-to-27-Month-Old Farmworker Children for Use in Exposure Assessment

    PubMed Central

    Beamer, Paloma; Key, Maya E.; Ferguson, Alesia C.; Canales, Robert A.; Auyeung, Willa; Leckie, James O.

    2008-01-01

    This study was conducted to describe exposure prone behaviors of infants and toddlers in the farmworker community. Analysis of hand and mouth contact frequencies and durations aids understanding of how children interact with their environment and are exposed via contact with surfaces. All 23 participating children (8 female infants, 5 male infants, 5 female toddlers and 5 male toddlers) lived with at least one farmworker. Children were videotaped at home for 2–6 hours. Video footage was translated into micro- level activity time series (MLATS) for both hands and the mouth. MLATS were processed to calculate hourly duration in microenvironments, contact frequency, hourly contact duration and median contact duration. The median hourly duration spent indoors was 53 min/hr. The median hand-to-mouth frequency was 15.2 events/hr and the median object-to-mouth frequency was 27.2 events/hr. The hourly mouthing duration was 1.2 and 2.2 min/hr with the hands and objects respectively. The median mouthing duration with hands and objects was 2 seconds. The median contact frequency for both hands combined was 689.4 events/hr with an hourly contact duration of 100.5 min/hr and a median contact duration of 3 seconds. Infants had higher mouthing frequencies with non-dietary objects while toddlers had higher mouthing frequencies with objects associated with pica (i.e., paper). Boys had higher contact frequencies while girls had longer contact durations. These sub-group differences indicate factors such as age and gender should be accounted for when conducting exposure assessments. Contact frequencies in this study are higher than current U.S. EPA recommendations, questioning their protective value for infants and toddlers. PMID:18723168

  10. Measurement and simulation of unmyelinated nerve electrostimulation: Lumbricus terrestris experiment and numerical model

    NASA Astrophysics Data System (ADS)

    Šarolić, A.; Živković, Z.; Reilly, J. P.

    2016-06-01

    The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sinusoidal current. Experiments were performed on the single-axon measurement setup based on Lumbricus terrestris having unmyelinated nerve fibers. The simulations were performed using the well-established SENN model for a myelinated nerve. Although the unmyelinated experimental model differs from the myelinated simulation model, both refer to a single axon. Thus we hypothesized that the dependence on temporal and frequency parameters should be very similar. The comparison was made possible by normalizing each set of results to the SD time constant and the rheobase current of each model, yielding the curves that show the temporal and frequency dependencies regardless of the model differences. The results reasonably agree, suggesting that this experimental setup and method of comparison with SENN model can be used for further studies of waveform effect on nerve excitability, including unmyelinated neurons.

  11. Measurement and simulation of unmyelinated nerve electrostimulation: Lumbricus terrestris experiment and numerical model.

    PubMed

    Šarolić, A; Živković, Z; Reilly, J P

    2016-06-21

    The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sinusoidal current. Experiments were performed on the single-axon measurement setup based on Lumbricus terrestris having unmyelinated nerve fibers. The simulations were performed using the well-established SENN model for a myelinated nerve. Although the unmyelinated experimental model differs from the myelinated simulation model, both refer to a single axon. Thus we hypothesized that the dependence on temporal and frequency parameters should be very similar. The comparison was made possible by normalizing each set of results to the SD time constant and the rheobase current of each model, yielding the curves that show the temporal and frequency dependencies regardless of the model differences. The results reasonably agree, suggesting that this experimental setup and method of comparison with SENN model can be used for further studies of waveform effect on nerve excitability, including unmyelinated neurons.

  12. Insights in Low Frequency Earthquake Source Processes from Observations of Their Size-Duration Scaling

    NASA Astrophysics Data System (ADS)

    Farge, G.; Shapiro, N.; Frank, W.; Mercury, N.; Vilotte, J. P.

    2017-12-01

    Low frequency earthquakes (LFE) are detected in association with volcanic and tectonic tremor signals as impulsive, repeated, low frequency (1-5 Hz) events originating from localized sources. While the mechanism causing this depletion of the high frequency content of their signal is still unknown, this feature may indicate that the source processes at the origin of LFE are different from those for regular earthquakes. Tectonic LFE are often associated with slip instabilities in the brittle-ductile transition zones of active faults and volcanic LFE with fluid transport in magmatic and hydrothermal systems. Key constraints on the LFE-generating physical mechanisms can be obtained by establishing scaling laws between their sizes and durations. We apply a simple spectral analysis method to the S-waveforms of each LFE to retrieve its seismic moment and corner frequency. The former characterizes the earthquake's size while the latter is inversely proportional to its duration. First, we analyze a selection of tectonic LFE from the Mexican "Sweet Spot" (Guerrero, Mexico). We find characteristic values of M ˜ 1013 N.m (Mw ˜ 2.6) and fc ˜ 2 Hz. The moment-corner frequency distribution compared to values reported in previous studies in tectonic contexts is consistent with the scaling law suggested by Bostock et al. (2015): fc ˜ M-1/10 . We then apply the same source- parameters determination method to deep volcanic LFE detected in the Klyuchevskoy volcanic group in Kamtchatka, Russia. While the seismic moments for these earthquakes are slightly smaller, they still approximately follow the fc ˜ M-1/10 scaling. This size-duration scaling observed for LFE is very different from the one established for regular earthquakes (fc ˜ M-1/3) and from the scaling more recently suggested by Ide et al. (2007) for the broad class of "slow earthquakes". The scaling observed for LFE suggests that they are generated by sources of nearly constant size with strongly varying intensities. LFE then do not exhibit the self-similarity characteristic of regular earthquakes, strongly suggesting that the physical mechanisms at their origin are different. Moreover, the agreement with the size-duration scaling for both tectonic and volcanic LFE might indicate a similarity in their source behavior.

  13. Study of the eclipse region of the redback millisecond pulsar J1431-4715

    NASA Astrophysics Data System (ADS)

    Miraval Zanon, A.; Burgay, M.; Possenti, A.; Ridolfi, A.

    2018-01-01

    We report on the rotational, astrometric and orbital parameters for PSR J1431-4715, and we also present a preliminary analysis of the eclipsing region. This pulsar was discovered in the High Time Resolution Universe survey and it belongs to the class of “redback” systems. The minimum estimated mass for the companion of J1431-4715 is, indeed, 0.13 M⊙. Thanks to multi-frequency observations, obtained at the 64 m Parkes radio telescope, we note that the magnitude and the duration of the eclipse delay depend upon the observing frequency.

  14. Evaluation of stimulation parameters on aortomyoplasty, using Latissimus Dorsi muscle in a goat model: an acute study.

    PubMed

    Hakami, A; Santamore, W P; Stremel, R W; Tobin, G; Hjortdal, V E

    1999-08-01

    Dynamic aortomyoplasty using Latissimus Dorsi muscle (LDM) has been shown to improve myocardial function. However, systematic examination of the effects of stimulation parameters on aortic wrap function has not been done. Thus, the present study measures the direct effect of stimulation voltage, pulse train duration, frequency of the pulses, and the duration of the stimulation delay from R wave on the aortic wrap function. In eight female goats, the left LDM was wrapped around the descending aorta. The muscle was then subjected to electrical stimulation, altering frequency of stimulation pulses (16.6, 20, 25, 33 and 50 Hz), amplitude (2, 4, 6, 8 and 10 V), and number of pulses (2, 4, 6, 8 and 10 pulses) in a train stimulation. Left ventricular, aortic pressure, and pressure generated by LDM on aorta (wrap pressure) was measured. The changes in hemodynamic parameters mentioned above were calculated and compared for different stimulation parameters during unassisted and assisted cardiac cycles. Aortomyoplasty counterpulsation using LDM provided significant improvement in wrap pressure (78 mmHg +/- 2), aortic diastolic pressure, and changes in aortic diastolic pressure from 2 to 4 V (P < 0.05). Further increase in amplitude did not make any significant improvements of the above mentioned parameters. Significant augmentation of wrap pressure (82 mmHg +/- 2), aortic diastolic pressure (79 mmHg +/- 3) and changes in aortic diastolic pressure (12 mmHg +/- 1) occurred at 6 pulses (P < 0.05). Other changes in number of pulses did not show any significant improvements. Significant improvement of wrap pressure (80 mmHg +/- 2), aortic diastolic pressure (73 mmHg +/- 3) and changes in aortic diastolic pressure (12 mmHg +/- 1) was observed with a frequency of 33 Hz. To examine a wide range of delays from the onset of the QRS complex to LDM stimulation, stimulation was delivered randomly. The exact delay was determined from the ECG signal and superimposed LDM stimulation pulses. In this study we present a new measurement, wrap pressure. We also present that in aortomyoplasty using LDM, the most significant improvement in wrap pressure, aortic diastolic pressure and changes in aortic diastolic pressure occurs when the stimulation consists of an amplitude of 4 V, a frequency of 33 Hz and a train stimulation of 6 pulses.

  15. Behavioral and physiological changes during heat stress in Corriedale ewes exposed to water deprivation.

    PubMed

    Ghassemi Nejad, Jalil; Sung, Kyung-Il

    2017-01-01

    This study was conducted to investigate the behavioral and physiological changes of heat stressed Corriedale ewes exposed to water deprivation. Nine Corriedale ewes (average BW = 45 ± 3.7 kg) were individually fed diets based on maintenance requirements in metabolic crates. Ewes were assigned into three groups (9 sheep per treatment) according to a 3 × 3 Latin square design for 3 periods with 21-d duration for each period. The control (CON) group was given free access to water, 2 h water deprivation (2hWD), and 3 h water deprivation (3hWD) following feeding. No differences were found in fecal excretion frequency, standing frequency (number/d), and sitting frequency among the groups ( p  > 0.05). Measurements of standing duration (min/d) and urine excretion frequency (number/d) showed a significant decrease whereas sitting duration (min/d) showed a significant increase in the 2hWD and 3hWD groups when compared with the CON group ( p  < 0.05). Fecal score and heart rate (number/min) were not different among the groups ( p  > 0.05). However, respiratory rate (number/min) and panting score were found to be significantly higher in the 2hWD and 3hWD groups than in the CON group ( p  < 0.05). It is concluded that water deprivation following feeding intensifies physiological heat stress related indicators such as respiratory rate and panting score and changes behavioral parameters such as water intake and urine excretion frequency in heat stressed ewes. Daily adaptation to the extreme environmental conditions may occur actively in ewes.

  16. Damage assessment of RC buildings subjected to the different strong motion duration

    NASA Astrophysics Data System (ADS)

    Mortezaei, Alireza; mohajer Tabrizi, Mohsen

    2015-07-01

    An earthquake has three important characteristics; namely, amplitude, frequency content and duration. Amplitude and frequency content have a direct impact but not necessarily the sole cause of structural damage. Regarding the duration, some researchers show a high correlation between strong motion duration and structural damage whereas some others find no relation. This paper focuses on the ground motion durations characterized by Arias Intensity (AI). High duration may increase the damage state of structure for the damage accumulation. This paper investigates the response time histories (acceleration, velocity and displacement) of RC buildings under the different strong motion durations. Generally, eight earthquake records were selected from different soil type, and these records were grouped according to their PGA and frequency ranges. Maximum plastic rotation and drift response was chosen as damage indicator. In general, there was a positive correlation between strong motion duration and damage; however, in some PGA and frequency ranges input motions with shorter durations might cause more damage than the input motions with longer durations. In soft soils, input motions with longer durations caused more damage than the input motions with shorter durations.

  17. Analysis of the Duration of Rising Tone Chorus Elements

    NASA Astrophysics Data System (ADS)

    Teng, S.; Tao, X.; Xie, Y.; Zonca, F.; Chen, L.; Fang, W. B.; Wang, S.

    2017-12-01

    The duration of chorus elements is an important parameter to understand chorus excitation and to quantify the effects of nonlinear wave-particle interactions on energetic electron dynamics. In this work, we analyze the duration of rising tone chorus elements statistically using Van Allen Probes data. We present the distribution of chorus element duration (τ) as a function of magnetic local time (MLT) and the geomagnetic activity level characterized by auroral electrojet (AE) index. We show that the typical value of τ for nightside and dawnside is about 0.12 s, smaller than that for dayside and duskside by about a factor of 2 to 4. Using a previously developed hybrid code, DAWN, we suggest that the background magnetic field inhomogeneity might be an important factor in controlling the chorus element duration. We also report that τ is larger during quiet times and shorter during moderate and active periods; this result is consistent with the MLT dependence of τ and the occurrence pattern of chorus waves at different levels of geomagnetic activity. We then investigate the correlation between τ and the frequency chirping rate (Γ). We show that, from observation, τ scales with Γ as τ∝Γ-1.1, suggesting that statistically the frequency range of chorus elements (τΓ) should be roughly the same for different elements. These findings should be useful to the further development of a theoretical model of chorus excitation and to the quantification of nonlinear wave-particle interactions on energetic electron dynamics.

  18. Frequency tuning of synaptic inhibition underlying duration-tuned neurons in the mammalian inferior colliculus

    PubMed Central

    Valdizón-Rodríguez, Roberto

    2017-01-01

    Inhibition plays an important role in creating the temporal response properties of duration-tuned neurons (DTNs) in the mammalian inferior colliculus (IC). Neurophysiological and computational studies indicate that duration selectivity in the IC is created through the convergence of excitatory and inhibitory synaptic inputs offset in time. We used paired-tone stimulation and extracellular recording to measure the frequency tuning of the inhibition acting on DTNs in the IC of the big brown bat (Eptesicus fuscus). We stimulated DTNs with pairs of tones differing in duration, onset time, and frequency. The onset time of a short, best-duration (BD), probe tone set to the best excitatory frequency (BEF) was varied relative to the onset of a longer-duration, nonexcitatory (NE) tone whose frequency was varied. When the NE tone frequency was near or within the cell’s excitatory bandwidth (eBW), BD tone-evoked spikes were suppressed by an onset-evoked inhibition. The onset of the spike suppression was independent of stimulus frequency, but both the offset and duration of the suppression decreased as the NE tone frequency departed from the BEF. We measured the inhibitory frequency response area, best inhibitory frequency (BIF), and inhibitory bandwidth (iBW) of each cell. We found that the BIF closely matched the BEF, but the iBW was broader and usually overlapped the eBW measured from the same cell. These data suggest that temporal selectivity of midbrain DTNs is created and preserved by having cells receive an onset-evoked, constant-latency, broadband inhibition that largely overlaps the cell’s excitatory receptive field. We conclude by discussing possible neural sources of the inhibition. NEW & NOTEWORTHY Duration-tuned neurons (DTNs) arise from temporally offset excitatory and inhibitory synaptic inputs. We used single-unit recording and paired-tone stimulation to measure the spectral tuning of the inhibitory inputs to DTNs. The onset of inhibition was independent of stimulus frequency; the offset and duration of inhibition systematically decreased as the stimulus departed from the cell’s best excitatory frequency. Best inhibitory frequencies matched best excitatory frequencies; however, inhibitory bandwidths were more broadly tuned than excitatory bandwidths. PMID:28100657

  19. Modular compact solid-state modulators for particle accelerators

    NASA Astrophysics Data System (ADS)

    Zavadtsev, A. A.; Zavadtsev, D. A.; Churanov, D. V.

    2017-12-01

    The building of the radio frequency (RF) particle accelerator needs high-voltage pulsed modulator as a power supply for klystron or magnetron to feed the RF accelerating system. The development of a number of solid-state modulators for use in linear accelerators has allowed to develop a series of modular IGBT based compact solid-state modulators with different parameters. This series covers a wide range of needs in accelerator technology to feed a wide range of loads from the low power magnetrons to powerful klystrons. Each modulator of the series is built on base of a number of unified solid-state modules connected to the pulse transformer, and covers a wide range of modulators: voltage up to 250 kV, a peak current up to 250 A, average power up to 100 kW and the pulse duration up to 20 μsec. The parameters of the block with an overall dimensions 880×540×250 mm are: voltage 12 kV, peak current 1600 A, pulse duration 20 μsec, average power 10 kW with air-cooling and 40 kW with liquidcooling. These parameters do not represent a physical limit, and modulators to parameters outside these ranges can be created on request.

  20. Recent trends in the frequency and duration of global floods

    NASA Astrophysics Data System (ADS)

    Najibi, Nasser; Devineni, Naresh

    2018-06-01

    Frequency and duration of floods are analyzed using the global flood database of the Dartmouth Flood Observatory (DFO) to explore evidence of trends during 1985-2015 at global and latitudinal scales. Three classes of flood duration (i.e., short: 1-7, moderate: 8-20, and long: 21 days and above) are also considered for this analysis. The nonparametric Mann-Kendall trend analysis is used to evaluate three hypotheses addressing potential monotonic trends in the frequency of flood, moments of duration, and frequency of specific flood duration types. We also evaluated if trends could be related to large-scale atmospheric teleconnections using a generalized linear model framework. Results show that flood frequency and the tails of the flood duration (long duration) have increased at both the global and the latitudinal scales. In the tropics, floods have increased 4-fold since the 2000s. This increase is 2.5-fold in the north midlatitudes. However, much of the trend in frequency and duration of the floods can be placed within the long-term climate variability context since the Atlantic Multidecadal Oscillation, North Atlantic Oscillation, and Pacific Decadal Oscillation were the main atmospheric teleconnections explaining this trend. There is no monotonic trend in the frequency of short-duration floods across all the global and latitudinal scales. There is a significant increasing trend in the annual median of flood durations globally and each latitudinal belt, and this trend is not related to these teleconnections. While the DFO data come with a certain level of epistemic uncertainty due to imprecision in the estimation of floods, overall, the analysis provides insights for understanding the frequency and persistence in hydrologic extremes and how they relate to changes in the climate, organization of global and local dynamical systems, and country-scale socioeconomic factors.

  1. Generalized ruin problems and asynchronous random walks

    NASA Astrophysics Data System (ADS)

    Abad, E.

    2005-07-01

    We consider a gambling game with two different kinds of trials and compute the duration of the game (averaged over all possible initial capitals of the players) by a mapping of the problem to a 1D lattice walk of two particles reacting upon encounter. The relative frequency of the trials is governed by the synchronicity parameter p of the random walk. The duration of the game is given by the mean time to reaction, which turns out to display a different behavior for even and odd lattices, i.e. this quantity is monotonic in p for odd lattices and non-monotonic for even lattices. In the game picture, this implies that the players minimize the duration of the game by restricting themselves to one type of trial if their joint capital is odd, otherwise a non-symmetric mixture of both trials is needed.

  2. Modeling Volcanic Eruption Parameters by Near-Source Internal Gravity Waves.

    PubMed

    Ripepe, M; Barfucci, G; De Angelis, S; Delle Donne, D; Lacanna, G; Marchetti, E

    2016-11-10

    Volcanic explosions release large amounts of hot gas and ash into the atmosphere to form plumes rising several kilometers above eruptive vents, which can pose serious risk on human health and aviation also at several thousands of kilometers from the volcanic source. However the most sophisticate atmospheric models and eruptive plume dynamics require input parameters such as duration of the ejection phase and total mass erupted to constrain the quantity of ash dispersed in the atmosphere and to efficiently evaluate the related hazard. The sudden ejection of this large quantity of ash can perturb the equilibrium of the whole atmosphere triggering oscillations well below the frequencies of acoustic waves, down to much longer periods typical of gravity waves. We show that atmospheric gravity oscillations induced by volcanic eruptions and recorded by pressure sensors can be modeled as a compact source representing the rate of erupted volcanic mass. We demonstrate the feasibility of using gravity waves to derive eruption source parameters such as duration of the injection and total erupted mass with direct application in constraining plume and ash dispersal models.

  3. Modeling Volcanic Eruption Parameters by Near-Source Internal Gravity Waves

    PubMed Central

    Ripepe, M.; Barfucci, G.; De Angelis, S.; Delle Donne, D.; Lacanna, G.; Marchetti, E.

    2016-01-01

    Volcanic explosions release large amounts of hot gas and ash into the atmosphere to form plumes rising several kilometers above eruptive vents, which can pose serious risk on human health and aviation also at several thousands of kilometers from the volcanic source. However the most sophisticate atmospheric models and eruptive plume dynamics require input parameters such as duration of the ejection phase and total mass erupted to constrain the quantity of ash dispersed in the atmosphere and to efficiently evaluate the related hazard. The sudden ejection of this large quantity of ash can perturb the equilibrium of the whole atmosphere triggering oscillations well below the frequencies of acoustic waves, down to much longer periods typical of gravity waves. We show that atmospheric gravity oscillations induced by volcanic eruptions and recorded by pressure sensors can be modeled as a compact source representing the rate of erupted volcanic mass. We demonstrate the feasibility of using gravity waves to derive eruption source parameters such as duration of the injection and total erupted mass with direct application in constraining plume and ash dispersal models. PMID:27830768

  4. EMG activation patterns associated with high frequency, long-duration intracortical microstimulation of primary motor cortex.

    PubMed

    Griffin, Darcy M; Hudson, Heather M; Belhaj-Saïf, Abderraouf; Cheney, Paul D

    2014-01-29

    The delivery of high-frequency, long-duration intracortical microstimulation (HFLD-ICMS) to primary motor cortex (M1) in primates produces hand movements to a common final end-point regardless of the starting hand position (Graziano et al., 2002). We have confirmed this general conclusion. We further investigated the extent to which the (1) temporal pattern, (2) magnitude, and (3) latency of electromyographic (EMG) activation associated with HFLD-ICMS-evoked movements are dependent on task conditions, including limb posture. HFLD-ICMS was applied to layer V sites in M1 cortex. EMG activation with HFLD-ICMS was evaluated while two male rhesus macaques performed a number of tasks in which the starting position of the hand could be varied throughout the workspace. HFLD-ICMS-evoked EMG activity was largely stable across all parameters tested independent of starting hand position. The most common temporal pattern of HFLD-ICMS-evoked EMG activity (58% of responses) was a sharp rise to a plateau. The plateau level was maintained essentially constant for the entire duration of the stimulus train. The plateau pattern is qualitatively different from the largely bell-shaped patterns typical of EMG activity associated with natural goal directed movements (Brown and Cooke, 1990; Hoffman and Strick, 1999). HFLD-ICMS produces relatively fixed parameters of muscle activation independent of limb position. We conclude that joint movement associated with HFLD-ICMS occurs as a function of the length-tension properties of stimulus-activated muscles until an equilibrium between agonist and antagonist muscle force is achieved.

  5. EMG Activation Patterns Associated with High Frequency, Long-Duration Intracortical Microstimulation of Primary Motor Cortex

    PubMed Central

    Griffin, Darcy M.; Hudson, Heather M.; Belhaj-Saïf, Abderraouf

    2014-01-01

    The delivery of high-frequency, long-duration intracortical microstimulation (HFLD-ICMS) to primary motor cortex (M1) in primates produces hand movements to a common final end-point regardless of the starting hand position (Graziano et al., 2002). We have confirmed this general conclusion. We further investigated the extent to which the (1) temporal pattern, (2) magnitude, and (3) latency of electromyographic (EMG) activation associated with HFLD-ICMS-evoked movements are dependent on task conditions, including limb posture. HFLD-ICMS was applied to layer V sites in M1 cortex. EMG activation with HFLD-ICMS was evaluated while two male rhesus macaques performed a number of tasks in which the starting position of the hand could be varied throughout the workspace. HFLD-ICMS-evoked EMG activity was largely stable across all parameters tested independent of starting hand position. The most common temporal pattern of HFLD-ICMS-evoked EMG activity (58% of responses) was a sharp rise to a plateau. The plateau level was maintained essentially constant for the entire duration of the stimulus train. The plateau pattern is qualitatively different from the largely bell-shaped patterns typical of EMG activity associated with natural goal directed movements (Brown and Cooke, 1990; Hoffman and Strick, 1999). HFLD-ICMS produces relatively fixed parameters of muscle activation independent of limb position. We conclude that joint movement associated with HFLD-ICMS occurs as a function of the length–tension properties of stimulus-activated muscles until an equilibrium between agonist and antagonist muscle force is achieved. PMID:24478348

  6. Patients' willingness to trade off between the duration and frequency of rheumatoid arthritis treatments.

    PubMed

    Poulos, Christine; Hauber, A Brett; González, Juan Marcos; Turpcu, Adam

    2014-07-01

    Biologic treatments for rheumatoid arthritis (RA) vary widely in both the time required to administer treatment and treatment frequency. This study aimed to quantify the rate at which RA patients are willing to trade off between the time required to administer treatment (duration) and treatment frequency. Respondents with a self-reported physician diagnosis of moderate to severe RA completed an online discrete choice experiment survey (also known as conjoint analysis). Respondents were presented with a series of treatment-choice questions. Each hypothetical treatment included 6 attributes: response rate, mode of administration, treatment duration, treatment frequency, and the risks of immediate mild and serious treatment reactions. Preference weights, also called marginal utilities or relative importances, were estimated using mixed-logit methods and then used to calculate the marginal rates of substitution between attributes, including treatment duration and treatment frequency. Among the 901 respondents, 505 were in the RA Information, Service, and Education group (www.risesupport.com) and 396 were members of an online panel. The marginal utility of changes in treatment features was largest for a 1-hour change in treatment duration, while a 1-unit change in the annual frequency of treatment was the second least important change. The marginal utility of changes in annual treatment frequency depends on the treatment duration and vice versa. Respondents would accept treatments with lower efficacy and greater risk to achieve lower duration and frequency. Previous studies have linked patient preferences to treatment adherence, suggesting that reductions in duration or frequency could improve adherence and health outcomes. Copyright © 2014 by the American College of Rheumatology.

  7. Frequency-scanning interferometry using a time-varying Kalman filter for dynamic tracking measurements.

    PubMed

    Jia, Xingyu; Liu, Zhigang; Tao, Long; Deng, Zhongwen

    2017-10-16

    Frequency scanning interferometry (FSI) with a single external cavity diode laser (ECDL) and time-invariant Kalman filtering is an effective technique for measuring the distance of a dynamic target. However, due to the hysteresis of the piezoelectric ceramic transducer (PZT) actuator in the ECDL, the optical frequency sweeps of the ECDL exhibit different behaviors, depending on whether the frequency is increasing or decreasing. Consequently, the model parameters of Kalman filter appear time varying in each iteration, which produces state estimation errors with time-invariant filtering. To address this, in this paper, a time-varying Kalman filter is proposed to model the instantaneous movement of a target relative to the different optical frequency tuning durations of the ECDL. The combination of the FSI method with the time-varying Kalman filter was theoretically analyzed, and the simulation and experimental results show the proposed method greatly improves the performance of dynamic FSI measurements.

  8. Variations in leaf growth parameters within the tree structure of adult Coffea arabica in relation to seasonal growth, water availability and air carbon dioxide concentration.

    PubMed

    Rakocevic, Miroslava; Matsunaga, Fabio Takeshi

    2018-04-05

    Dynamics in branch and leaf growth parameters, such as the phyllochron, duration of leaf expansion, leaf life span and bud mortality, determine tree architecture and canopy foliage distribution. We aimed to estimate leaf growth parameters in adult Arabica coffee plants based on leaf supporter axis order and position along the vertical profile, considering their modifications related to seasonal growth, air [CO2] and water availability. Growth and mortality of leaves and terminal buds of adult Arabica coffee trees were followed in two independent field experiments in two sub-tropical climate regions of Brazil, Londrina-PR (Cfa) and Jaguariúna-SP (Cwa). In the Cwa climate, coffee trees were grown under a FACE (free air CO2 enrichment) facility, where half of those had been irrigated. Plants were observed at a 15-30 d frequency for 1 year. Leaf growth parameters were estimated on five axes orders and expressed as functions of accumulated thermal time (°Cd per leaf). The phyllochron and duration of leaf expansion increased with axis order, from the seond to the fourth. The phyllochron and life span during the reduced vegetative seasonal growth were greater than during active growth. It took more thermal time for leaves from the first- to fourth-order axes to expand their blades under irrigation compared with rainfed conditions. The compensation effects of high [CO2] for low water availability were observed on leaf retention on the second and third axes orders, and duration of leaf expansion on the first- and fourth-order axes. The second-degree polynomials modelled leaf growth parameter distribution in the vertical tree profile, and linear regressions modelled the proportion of terminal bud mortality. Leaf growth parameters in coffee plants were determined by axis order. The duration of leaf expansion contributed to phyllochron determination. Leaf growth parameters varied according the position of the axis supporter along the vertical profile, suggesting an effect of axes age and micro-environmental light modulations.

  9. [Destruction of synovial pannus of antigen-induced arthritis by ultrasonic cavitation in rabbits].

    PubMed

    Zhang, Ling-yan; Qiu, Li; Wang, Lei; Lin, Ling; Wen, Xiao-rong

    2011-11-01

    To optimize the conditions of ultrasonic irradiation and microbubble of ultrasound cavitation on destruction of synovial pannus of antigen-induced arthritis (AIA) in rabbits. Antigen-induced arthritis was successfully induced on bilateral knee joints of 85 rabbits. Each 10 AIA rabbits were divided into two groups to compare various peak negative pressures, different ultrasonic pulse durations, various pulse repetition frequencies, different irradiance duration, different dosages of microbubble contrast agents, different ultrasonic irradiance times. With intravenous infusion of Sonovue to the rabbits, ultrasonic irradiance was performed on the right knee joint using the above condition of ultrasound cavitation. At the day 1 after ultrasonic irradiance, MRI and pathological examination were employed to evaluate the optimal conditions. The optimal parameters and conditions for ultrasonic irradiance included intermittent ultrasonic application (in 6 s intervals), 0.6 mL/kg of microbubble contrast agent, 4.6 MPa of ultrasonic peak negative pressure, 100 cycles of pulse duration, 50 Hz of pulse repetition frequency, 5 min of ultrasonic duration, 0.6 mL/kg of dosages of microbubble contrast agents and multi-sessional ultrasonic irradiance. After the ultrasonic irradiance, the thickness of right knee synovium measured by MRI was thinner than that of left knee and synovial necrosis was confirmed by the pathological finding. Under optimal ultrasonic irradiation and microbubble conditions, ultrasonic cavitation could destroy synovial pannus of AIA in rabbits.

  10. Interference of Overlapping Insect Vibratory Communication Signals: An Eushistus heros Model

    PubMed Central

    Čokl, Andrej; Laumann, Raul Alberto; Žunič Kosi, Alenka; Blassioli-Moraes, Maria Carolina; Virant-Doberlet, Meta; Borges, Miguel

    2015-01-01

    Plants limit the range of insect substrate-borne vibratory communication by their architecture and mechanical properties that change transmitted signal time, amplitude and frequency characteristics. Stinkbugs gain higher signal-to-noise ratio and increase communication distance by emitting narrowband low frequency vibratory signals that are tuned with transmission properties of plants. The objective of the present study was to investigate hitherto overlooked consequences of duetting with mutually overlapped narrowband vibratory signals. The overlapped vibrations of the model stinkbug species Eushistus heros, produced naturally or induced artificially on different plants, have been analysed. They represent female and male strategies to preserve information within a complex masked signal. The brown stinkbugs E. heros communicate with species and gender specific vibratory signals that constitute characteristic duets in the calling, courtship and rivalry phases of mating behaviour. The calling female pulse overlaps the male vibratory response when the latency of the latter is shorter than the duration of the female triggering signal or when the male response does not inhibit the following female pulse. Overlapping of signals induces interference that changes their amplitude pattern to a sequence of regularly repeated pulses in which their duration and the difference between frequencies of overlapped vibrations are related inversely. Interference does not occur in overlapped narrow band female calling pulses and broadband male courtship pulse trains. In a duet with overlapped signals females and males change time parameters and increase the frequency difference between signals by changing the frequency level and frequency modulation pattern of their calls. PMID:26098637

  11. Prediction of broadband ground-motion time histories: Hybrid low/high-frequency method with correlated random source parameters

    USGS Publications Warehouse

    Liu, P.; Archuleta, R.J.; Hartzell, S.H.

    2006-01-01

    We present a new method for calculating broadband time histories of ground motion based on a hybrid low-frequency/high-frequency approach with correlated source parameters. Using a finite-difference method we calculate low- frequency synthetics (< ∼1 Hz) in a 3D velocity structure. We also compute broadband synthetics in a 1D velocity model using a frequency-wavenumber method. The low frequencies from the 3D calculation are combined with the high frequencies from the 1D calculation by using matched filtering at a crossover frequency of 1 Hz. The source description, common to both the 1D and 3D synthetics, is based on correlated random distributions for the slip amplitude, rupture velocity, and rise time on the fault. This source description allows for the specification of source parameters independent of any a priori inversion results. In our broadband modeling we include correlation between slip amplitude, rupture velocity, and rise time, as suggested by dynamic fault modeling. The method of using correlated random source parameters is flexible and can be easily modified to adjust to our changing understanding of earthquake ruptures. A realistic attenuation model is common to both the 3D and 1D calculations that form the low- and high-frequency components of the broadband synthetics. The value of Q is a function of the local shear-wave velocity. To produce more accurate high-frequency amplitudes and durations, the 1D synthetics are corrected with a randomized, frequency-dependent radiation pattern. The 1D synthetics are further corrected for local site and nonlinear soil effects by using a 1D nonlinear propagation code and generic velocity structure appropriate for the site’s National Earthquake Hazards Reduction Program (NEHRP) site classification. The entire procedure is validated by comparison with the 1994 Northridge, California, strong ground motion data set. The bias and error found here for response spectral acceleration are similar to the best results that have been published by others for the Northridge rupture.

  12. Associations of Frequency and Duration of Patient-Doctor Contact in Hemodialysis Facilities with Mortality

    PubMed Central

    Karaboyas, Angelo; Robinson, Bruce M.; Li, Yun; Fukuhara, Shunichi; Bieber, Brian A.; Rayner, Hugh C.; Andreucci, Vittorio E.; Pisoni, Ronald L.; Port, Friedrich K.; Morgenstern, Hal; Akizawa, Tadao; Saran, Rajiv

    2013-01-01

    It is unknown whether regular patient-doctor contact (PDC) contributes to better outcomes for patients undergoing hemodialysis. Here, we analyzed the associations between frequency and duration of PDC during hemodialysis treatments with clinical outcomes among 24,498 patients from 778 facilities in the international Dialysis Outcomes and Practice Patterns Study (DOPPS). The typical facility PDC frequency, estimated by facility personnel, was high (more than once per week) for 55% of facilities, intermediate (once per week) for 24%, and low (less than once per week) for 21%. The mean ± SD estimated duration of a typical interaction between patient and physician was 7.7±5.6 minutes. PDC frequency and duration varied across DOPPS phases and countries; the proportion of facilities with high PDC frequency was 17% in the United States and 73% across the other countries. Compared with high PDC frequency, the adjusted hazard ratio (HR) for all-cause mortality was 1.06 (95% confidence interval [CI], 0.96 to 1.17) for intermediate PDC frequency and 1.11 (95% CI, 1.01 to 1.23) for low PDC frequency (P=0.03 for trend). Furthermore, each 5-minutes-shorter duration of PDC was associated with a 5% higher risk for death, on average (HR, 1.05; 95% CI, 1.01 to 1.09), adjusted for PDC frequency and other covariates. Multivariable analyses also suggested modest inverse associations between both PDC frequency and duration with hospitalization but not with kidney transplantation. Taken together, these results suggest that policies supporting more frequent and longer duration of PDC may improve patient outcomes in hemodialysis. PMID:23886592

  13. Neural control and modulation of swimming speed in the larval zebrafish

    PubMed Central

    Marques, João C.; O'Malley, Donald M.; Orger, Michael B.; Engert, Florian

    2014-01-01

    Summary Vertebrate locomotion at different speeds is driven by descending excitatory connections to central pattern generators in the spinal cord. To investigate how these inputs determine locomotor kinematics, we used whole-field visual motion to drive zebrafish to swim at different speeds. Larvae match the stimulus speed by utilizing more locomotor events, or modifying kinematic parameters such as the duration and speed of swimming bouts, the tail-beat frequency, and choice of gait. We used laser ablations, electrical stimulation, and activity recordings in descending neurons of the nucleus of the medial longitudinal fasciculus (nMLF) to dissect their contribution to controlling forward movement. We found that the activity of single identified neurons within the nMLF is correlated with locomotor kinematics, and modulates both the duration and oscillation frequency of tail movements. By identifying the contribution of individual supraspinal circuit elements to locomotion kinematics we build a better understanding of how the brain controls movement. PMID:25066084

  14. Neural control and modulation of swimming speed in the larval zebrafish.

    PubMed

    Severi, Kristen E; Portugues, Ruben; Marques, João C; O'Malley, Donald M; Orger, Michael B; Engert, Florian

    2014-08-06

    Vertebrate locomotion at different speeds is driven by descending excitatory connections to central pattern generators in the spinal cord. To investigate how these inputs determine locomotor kinematics, we used whole-field visual motion to drive zebrafish to swim at different speeds. Larvae match the stimulus speed by utilizing more locomotor events, or modifying kinematic parameters such as the duration and speed of swimming bouts, the tail-beat frequency, and the choice of gait. We used laser ablations, electrical stimulation, and activity recordings in descending neurons of the nucleus of the medial longitudinal fasciculus (nMLF) to dissect their contribution to controlling forward movement. We found that the activity of single identified neurons within the nMLF is correlated with locomotor kinematics, and modulates both the duration and oscillation frequency of tail movements. By identifying the contribution of individual supraspinal circuit elements to locomotion kinematics, we build a better understanding of how the brain controls movement. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Dispersive distortions of a radio-wave pulse in a double-resonance gaseous medium

    NASA Astrophysics Data System (ADS)

    Strelkov, G. M.

    2017-03-01

    The problem on dispersive distortions of an electromagnetic pulse in a gaseous medium with two isolated resonant frequencies is solved analytically. The solution is obtained directly in the time region and, thus, is not the result of calculations of the Fourier integral. Without introducing additional assumptions, it is possible to study the regularities and the features of the process of propagation of pulses caused by variations of both their initial characteristics and the parameters of the propagation medium. As an example, the solution is applied to describe the distortions of the two-frequency pulse of subnanosecond duration in the terrestrial atmosphere.

  16. Discrimination of nonlinear frequency glides.

    PubMed

    Thyer, Nick; Mahar, Doug

    2006-05-01

    Discrimination thresholds for short duration nonlinear tone glides that differed in glide rate were measured in order to determine whether cues related to rate of frequency change alone were sufficient for discrimination. Thresholds for rising and falling nonlinear glides of 50-ms and 400-ms duration, spanning three frequency excursions (0.5, 1, and 2 ERBs) at three center frequencies (0.5, 2.0, and 6.0 kHz) were measured. Results showed that glide discrimination was possible when duration and initial and final frequencies were identical. Thresholds were of a different order to those found in previous studies using linear frequency glides where endpoint frequency or duration information is available as added cues. The pattern of results was suggestive of a mechanism sensitive to spectral changes in time. Thresholds increased as the rate of transition span increased, particularly above spans of 1 ERB. The Weber fraction associated with these changes was 0.6-0.7. Overall, the results were consistent with an excitation pattern model of nonlinear glide detection that has difficulty in tracking signals with rapid frequency changes that exceed the width of an auditory filter and are of short duration.

  17. Using Four Downscaling Techniques to Characterize Uncertainty in Updating Intensity-Duration-Frequency Curves Under Climate Change

    NASA Astrophysics Data System (ADS)

    Cook, L. M.; Samaras, C.; McGinnis, S. A.

    2017-12-01

    Intensity-duration-frequency (IDF) curves are a common input to urban drainage design, and are used to represent extreme rainfall in a region. As rainfall patterns shift into a non-stationary regime as a result of climate change, these curves will need to be updated with future projections of extreme precipitation. Many regions have begun to update these curves to reflect the trends from downscaled climate models; however, few studies have compared the methods for doing so, as well as the uncertainty that results from the selection of the native grid scale and temporal resolution of the climate model. This study examines the variability in updated IDF curves for Pittsburgh using four different methods for adjusting gridded regional climate model (RCM) outputs into station scale precipitation extremes: (1) a simple change factor applied to observed return levels, (2) a naïve adjustment of stationary and non-stationary Generalized Extreme Value (GEV) distribution parameters, (3) a transfer function of the GEV parameters from the annual maximum series, and (4) kernel density distribution mapping bias correction of the RCM time series. Return level estimates (rainfall intensities) and confidence intervals from these methods for the 1-hour to 48-hour duration are tested for sensitivity to the underlying spatial and temporal resolution of the climate ensemble from the NA-CORDEX project, as well as, the future time period for updating. The first goal is to determine if uncertainty is highest for: (i) the downscaling method, (ii) the climate model resolution, (iii) the climate model simulation, (iv) the GEV parameters, or (v) the future time period examined. Initial results of the 6-hour, 10-year return level adjusted with the simple change factor method using four climate model simulations of two different spatial resolutions show that uncertainty is highest in the estimation of the GEV parameters. The second goal is to determine if complex downscaling methods and high-resolution climate models are necessary for updating, or if simpler methods and lower resolution climate models will suffice. The final results can be used to inform the most appropriate method and climate model resolutions to use for updating IDF curves for urban drainage design.

  18. Formation of Large-Amplitude Wave Groups in an Experimental Model Basin

    DTIC Science & Technology

    2008-08-01

    varying parameters, including amplitude, frequency, and signal duration. Superposition of thes finite regular waves produced repeatable wave groups at a...19 Regular Waves 20 Irregular Waves 21 Senix Wave Gages 21 GLRP 23 Instrumentation Calibration and Uncertainty 26 Senix Ultrasonic Wave Gages... signal output from sine wave superposition, two sine waves combined: x] + x2 (top) and x3 + x4 (middle), all four waves (x, + x2 + x, + xA

  19. Experimental investigation on frequency characteristics of plasma synthetic jets

    NASA Astrophysics Data System (ADS)

    Zong, Haohua; Kotsonis, Marios

    2017-11-01

    The performance of a two-electrode plasma synthetic jet actuator (PSJA) is investigated for a wide range of dimensionless actuation frequencies ( f*) using high-speed phase-locked particle imaging velocimetry measurements. The jet-induced velocity fields in the axisymmetric plane are measured during both transient and steady working stages of the PSJA. When f* increases, the jet duration time (Tjet) is reduced, while the peak suction velocity (Us) increases consistently. Three integral parameters including the total expelled gas mass, impulse, and issued mechanical energy also decline considerably with increasing frequency, which is shown to relate to both the reduced cavity density and the decreasing jet duration. Theoretical analysis reveals that the mean cavity density decreases monotonically with the square root of the discharge frequency. The decreasing rate is inversely proportional to a thermal cut-off frequency ( fc, 210 Hz for the current study), which scales with the convective heat transfer coefficient between the actuator cavity walls and the cavity gas, as well as the area of the cavity internal surface. In the time-averaged velocity fields, the jet centreline velocity (U¯ c) exhibits a local maximum in the axial coordinate. The nondimensional maximum centreline velocity reduces with increasing frequency of operation. The jet spreading rate of the plasma synthetic jets (PSJs) decreases from 0.14 to 0.09 with increasing frequency. During the transient working stage of a PSJ, the exit velocity trace elapses 20 successive actuation cycles to stabilize. In contrast to the exit velocity, approximately 130 cycles are needed for the mean cavity density/temperature to reach steady values.

  20. Bradykinesia induced by frequency-specific pallidal stimulation in patients with cervical and segmental dystonia.

    PubMed

    Huebl, Julius; Brücke, Christof; Schneider, Gerd-Helge; Blahak, Christian; Krauss, Joachim K; Kühn, Andrea A

    2015-07-01

    Pallidal deep brain stimulation (DBS) is an effective treatment for patients with primary dystonia leading to a substantial reduction of symptom severity. However, stimulation induced side effects such as bradykinesia have also been reported recently. The influence of stimulation parameters on such side effects have not yet been systemically assessed in these patients. Here we tested the effect of stimulation frequency and duration of stimulation period on hand motor function in 22 patients with primary cervical and segmental dystonia using an unimanual tapping task. Patients performed the task at 4 different stimulation frequencies (0 Hz = OFF stimulation, 20, 50 and ≥130 Hz = high frequency stimulation) after either an SHORT (5 min, N = 16) or a LONG (60 min, N = 6) stimulation period (i.e. changing of DBS-frequency). The change of overall mobility under HFS compared to the preoperative state was assessed with a 5-point Likert-scale. Tapping performance was analysed using a repeated measures ANOVA with the main factor 'FREQUENCY'. Tapping performance at HFS and changes in general mobility were correlated using Spearman's Rho. We found a frequency specific modulation of hand motor function: HFS led to deterioration and 20 Hz stimulation to improvement of tapping rate. The effects were predominant in the 'LONG' group suggesting a significant contribution of stimulation duration. This is important to consider during DBS-programming and evaluation of potential side effects. Furthermore, the impairment in hand motor function under HFS was mirrored by the patients' observation of a deterioration of general mobility. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Regional intensity-duration-frequency analysis in the Eastern Black Sea Basin, Turkey, by using L-moments and regression analysis

    NASA Astrophysics Data System (ADS)

    Ghiaei, Farhad; Kankal, Murat; Anilan, Tugce; Yuksek, Omer

    2018-01-01

    The analysis of rainfall frequency is an important step in hydrology and water resources engineering. However, a lack of measuring stations, short duration of statistical periods, and unreliable outliers are among the most important problems when designing hydrology projects. In this study, regional rainfall analysis based on L-moments was used to overcome these problems in the Eastern Black Sea Basin (EBSB) of Turkey. The L-moments technique was applied at all stages of the regional analysis, including determining homogeneous regions, in addition to fitting and estimating parameters from appropriate distribution functions in each homogeneous region. We studied annual maximum rainfall height values of various durations (5 min to 24 h) from seven rain gauge stations located in the EBSB in Turkey, which have gauging periods of 39 to 70 years. Homogeneity of the region was evaluated by using L-moments. The goodness-of-fit criterion for each distribution was defined as the ZDIST statistics, depending on various distributions, including generalized logistic (GLO), generalized extreme value (GEV), generalized normal (GNO), Pearson type 3 (PE3), and generalized Pareto (GPA). GLO and GEV determined the best distributions for short (5 to 30 min) and long (1 to 24 h) period data, respectively. Based on the distribution functions, the governing equations were extracted for calculation of intensities of 2, 5, 25, 50, 100, 250, and 500 years return periods (T). Subsequently, the T values for different rainfall intensities were estimated using data quantifying maximum amount of rainfall at different times. Using these T values, duration, altitude, latitude, and longitude values were used as independent variables in a regression model of the data. The determination coefficient ( R 2) value indicated that the model yields suitable results for the regional relationship of intensity-duration-frequency (IDF), which is necessary for the design of hydraulic structures in small and medium sized catchments.

  2. Modelling of extreme rainfall events in Peninsular Malaysia based on annual maximum and partial duration series

    NASA Astrophysics Data System (ADS)

    Zin, Wan Zawiah Wan; Shinyie, Wendy Ling; Jemain, Abdul Aziz

    2015-02-01

    In this study, two series of data for extreme rainfall events are generated based on Annual Maximum and Partial Duration Methods, derived from 102 rain-gauge stations in Peninsular from 1982-2012. To determine the optimal threshold for each station, several requirements must be satisfied and Adapted Hill estimator is employed for this purpose. A semi-parametric bootstrap is then used to estimate the mean square error (MSE) of the estimator at each threshold and the optimal threshold is selected based on the smallest MSE. The mean annual frequency is also checked to ensure that it lies in the range of one to five and the resulting data is also de-clustered to ensure independence. The two data series are then fitted to Generalized Extreme Value and Generalized Pareto distributions for annual maximum and partial duration series, respectively. The parameter estimation methods used are the Maximum Likelihood and the L-moment methods. Two goodness of fit tests are then used to evaluate the best-fitted distribution. The results showed that the Partial Duration series with Generalized Pareto distribution and Maximum Likelihood parameter estimation provides the best representation for extreme rainfall events in Peninsular Malaysia for majority of the stations studied. Based on these findings, several return values are also derived and spatial mapping are constructed to identify the distribution characteristic of extreme rainfall in Peninsular Malaysia.

  3. Probe Measurements of Parameters of Streamers of Nanosecond Frequency Crown Discharge

    NASA Astrophysics Data System (ADS)

    Ponizovskiy, A. Z.; Gosteev, S. G.

    2017-12-01

    Investigations of the parameters of single streamers of nanosecond frequency corona discharge, creating a voluminous low-temperature plasma in extended coaxial electrode systems, are performed. Measurements of the parameters of streamers were made by an isolated probe situated on the outer grounded electrode. Streamers were generated under the action of voltage pulses with a front of 50-300 ns, duration of 100-600 ns, and amplitude up to 100 kV at the frequency of 50-1000 Hz. The pulse voltage, the total current of the corona, current per probe, and glow in the discharge gap were recorded in the experiments. It was established that, at these parameters of pulse voltage, streamers propagate at an average strength of the electric field of 4-10 kV/cm. Increasing the pulse amplitude leads to an increase in the number of streamers hitting the probe, an increase in the average charge of the head of a streamer, and, as a consequence, an increase in the total streamer current and the energy introduced into the gas. In the intervals up to 3 cm, streamer breakdown at an average field strength of 5-10 kV/cm is possible. In longer intervals, during the buildup of voltage after generation of the main pulse, RF breakdown is observed at E av ≈ 4 kV/cm.

  4. Optimization of input parameters of acoustic-transfection for the intracellular delivery of macromolecules using FRET-based biosensors

    NASA Astrophysics Data System (ADS)

    Yoon, Sangpil; Wang, Yingxiao; Shung, K. K.

    2016-03-01

    Acoustic-transfection technique has been developed for the first time. We have developed acoustic-transfection by integrating a high frequency ultrasonic transducer and a fluorescence microscope. High frequency ultrasound with the center frequency over 150 MHz can focus acoustic sound field into a confined area with the diameter of 10 μm or less. This focusing capability was used to perturb lipid bilayer of cell membrane to induce intracellular delivery of macromolecules. Single cell level imaging was performed to investigate the behavior of a targeted single-cell after acoustic-transfection. FRET-based Ca2+ biosensor was used to monitor intracellular concentration of Ca2+ after acoustic-transfection and the fluorescence intensity of propidium iodide (PI) was used to observe influx of PI molecules. We changed peak-to-peak voltages and pulse duration to optimize the input parameters of an acoustic pulse. Input parameters that can induce strong perturbations on cell membrane were found and size dependent intracellular delivery of macromolecules was explored. To increase the amount of delivered molecules by acoustic-transfection, we applied several acoustic pulses and the intensity of PI fluorescence increased step wise. Finally, optimized input parameters of acoustic-transfection system were used to deliver pMax-E2F1 plasmid and GFP expression 24 hours after the intracellular delivery was confirmed using HeLa cells.

  5. Effect of Operating Frequency and Fill Time on PDE-Ejector Thrust Performance

    NASA Technical Reports Server (NTRS)

    Landry, K.; Santoro, Robert J.; Pal, Sibtosh; Shehadeh, R.; Bouvet, N.; Lee, S.-Y.

    2005-01-01

    Thrust measurements for a pulse detonation engine (PDE)-ejector system were determined for a range of operating frequencies. Various length tubular ejectors were utilized. The results were compared to the measurements of the thrust output of the PDE alone to determine the enhancement provided by each ejector configuration at the specified frequencies. Ethylene was chosen as the fuel, with an equi-molar mixture of nitrogen and oxygen acting as the oxidizer. The propellant was kept at an equivalence ratio of one during all the experiments. The system was operated for frequencies between 20 and 50 Hz. The parameter space of the study included PDE operation frequency, ejector length, overlap percentage, the radius of curvature for the ejector inlets, and duration of the time allowed between cycles. The results of the experiments showed a maximum thrust augmentation of 120% for a PDE-ejector configuration at a frequency of 40Hz with a fill time of 10 ms.

  6. Human sensitivity to differences in the rate of auditory cue change.

    PubMed

    Maloff, Erin S; Grantham, D Wesley; Ashmead, Daniel H

    2013-05-01

    Measurement of sensitivity to differences in the rate of change of auditory signal parameters is complicated by confounds among duration, extent, and velocity of the changing signal. Dooley and Moore [(1988) J. Acoust. Soc. Am. 84(4), 1332-1337] proposed a method for measuring sensitivity to rate of change using a duration discrimination task. They reported improved duration discrimination when an additional intensity or frequency change cue was present. The current experiments were an attempt to use this method to measure sensitivity to the rate of change in intensity and spatial position. Experiment 1 investigated whether duration discrimination was enhanced when additional cues of rate of intensity change, rate of spatial position change, or both were provided. Experiment 2 determined whether participant listening experience or the testing environment influenced duration discrimination task performance. Experiment 3 assessed whether duration discrimination could be used to measure sensitivity to rates of changes in intensity and spatial position for stimuli with lower rates of change, as well as emphasizing the constancy of the velocity cue. Results of these experiments showed that duration discrimination was impaired rather than enhanced by the additional velocity cues. The findings are discussed in terms of the demands of listening to concurrent changes along multiple auditory dimensions.

  7. Effects of frequency and duration on psychometric functions for detection of increments and decrements in sinusoids in noise.

    PubMed

    Moore, B C; Peters, R W; Glasberg, B R

    1999-12-01

    Psychometric functions for detecting increments or decrements in level of sinusoidal pedestals were measured for increment and decrement durations of 5, 10, 20, 50, 100, and 200 ms and for frequencies of 250, 1000, and 4000 Hz. The sinusoids were presented in background noise intended to mask spectral splatter. A three-interval, three-alternative procedure was used. The results indicated that, for increments, the detectability index d' was approximately proportional to delta I/I. For decrements, d' was approximately proportional to delta L. The slopes of the psychometric functions increased (indicating better performance) with increasing frequency for both increments and decrements. For increments, the slopes increased with increasing increment duration up to 200 ms at 250 and 1000 Hz, but at 4000 Hz they increased only up to 50 ms. For decrements, the slopes increased for durations up to 50 ms, and then remained roughly constant, for all frequencies. For a center frequency of 250 Hz, the slopes of the psychometric functions for increment detection increased with duration more rapidly than predicted by a "multiple-looks" hypothesis, i.e., more rapidly than the square root of duration, for durations up to 50 ms. For center frequencies of 1000 and 4000 Hz, the slopes increased less rapidly than predicted by a multiple-looks hypothesis, for durations greater than about 20 ms. The slopes of the psychometric functions for decrement detection increased with decrement duration at a rate slightly greater than the square root of duration, for durations up to 50 ms, at all three frequencies. For greater durations, the increase in slope was less than proportional to the square root of duration. The results were analyzed using a model incorporating a simulated auditory filter, a compressive nonlinearity, a sliding temporal integrator, and a decision device based on a template mechanism. The model took into account the effects of both the external noise and an assumed internal noise. The model was able to account for the major features of the data for both increment and decrement detection.

  8. Observing continuous change in heart rate variability and photoplethysmography-derived parameters during the process of pain production/relief with thermal stimuli.

    PubMed

    Ye, Jing-Jhao; Lee, Kuan-Ting; Lin, Jing-Siang; Chuang, Chiung-Cheng

    2017-01-01

    Continuously monitoring and efficiently managing pain has become an important issue. However, no study has investigated a change in physiological parameters during the process of pain production/relief. This study modeled the process of pain production/relief using ramped thermal stimulation (no pain: 37°C water, process of pain production: a heating rate of 1°C/min, and subject feels pain: water kept at the painful temperature for each subject, with each segment lasting 10 min). In this duration, the variation of the heat rate variability and photoplethysmography-derived parameters was observed. A total of 40 healthy individuals participated: 30 in the trial group (14 males and 16 females with a mean age of 22.5±1.9 years) and 10 in the control group (7 males and 3 females with a mean age of 22.5±1.3 years). The results showed that the numeric rating scale value was 5.03±1.99 when the subjects felt pain, with a temperature of 43.54±1.70°C. Heart rate, R-R interval, low frequency, high frequency, photoplethysmography amplitude, baseline, and autonomic nervous system state showed significant changes during the pain production process, but these changes differed during the period Segment D (painful temperature 10: min). In summary, the study observed that physiological parameters changed qualitatively during the process of pain production and relief and found that the high frequency, low frequency, and photoplethysmography parameters seemed to have different responses in four situations (no pain, pain production, pain experienced, and pain relief). The trends of these variations may be used as references in the clinical setting for continuously observing pain intensity.

  9. Four Stokes parameter radio frequency polarimetry of a flare from AD Leonis

    NASA Technical Reports Server (NTRS)

    Spangler, S. R.; Rankin, J. M.; Shawhan, S. D.

    1974-01-01

    Observations of the four Stokes parameters of a 430 MHz flare from the UV Ceti-type star AD Leonis are presented. The maximum amplitude of the event was 0.52 flux units and the durations at one-half and one-tenth maximum were 12 and 40 seconds, respectively. The degree of circular polarization at maximum intensity was approximately 56 percent and was later observed to be as high as 92 percent. Linear polarization was also observed at a level of about 21 percent at flare maximum which allowed an upper limit of 440 radians - sq m to be placed on the rotation measure.

  10. Toward tsunami early warning system in Indonesia by using rapid rupture durations estimation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madlazim

    2012-06-20

    Indonesia has Indonesian Tsunami Early Warning System (Ina-TEWS) since 2008. The Ina-TEWS has used automatic processing on hypocenter; Mwp, Mw (mB) and Mj. If earthquake occurred in Ocean, depth < 70 km and magnitude > 7, then Ina-TEWS announce early warning that the earthquake can generate tsunami. However, the announcement of the Ina-TEWS is still not accuracy. Purposes of this research are to estimate earthquake rupture duration of large Indonesia earthquakes that occurred in Indian Ocean, Java, Timor sea, Banda sea, Arafura sea and Pasific ocean. We analyzed at least 330 vertical seismogram recorded by IRIS-DMC network using a directmore » procedure for rapid assessment of earthquake tsunami potential using simple measures on P-wave vertical seismograms on the velocity records, and the likelihood that the high-frequency, apparent rupture duration, T{sub dur}. T{sub dur} can be related to the critical parameters rupture length (L), depth (z), and shear modulus ({mu}) while T{sub dur} may be related to wide (W), slip (D), z or {mu}. Our analysis shows that the rupture duration has a stronger influence to generate tsunami than Mw and depth. The rupture duration gives more information on tsunami impact, Mo/{mu}, depth and size than Mw and other currently used discriminants. We show more information which known from the rupture durations. The longer rupture duration, the shallower source of the earthquake. For rupture duration greater than 50 s, the depth less than 50 km, Mw greater than 7, the longer rupture length, because T{sub dur} is proportional L and greater Mo/{mu}. Because Mo/{mu} is proportional L. So, with rupture duration information can be known information of the four parameters. We also suggest that tsunami potential is not directly related to the faulting type of source and for events that have rupture duration greater than 50 s, the earthquakes generated tsunami. With available real-time seismogram data, rapid calculation, rupture duration discriminant can be completed within 4-5 min after an earthquake occurs and thus can aid in effective, accuracy and reliable tsunami early warning for Indonesia region.« less

  11. Dynamic adjustment of echolocation pulse structure of big-footed myotis (Myotis macrodactylus) in response to different habitats.

    PubMed

    Wang, Lei; Luo, Jinhong; Wang, Hongna; Ou, Wei; Jiang, Tinglei; Liu, Ying; Lyle, Dennis; Feng, Jiang

    2014-02-01

    Studying relationships between characteristics of sonar pulses and habitat clutter level is important for the understanding of signal design in bat echolocation. However, most studies have focused on overall spectral and temporal parameters of such vocalizations, with focus less on potential variation in frequency modulation rates (MRs) occurring within each pulse. In the current study, frequency modulation (FM) characteristics were examined in echolocation pulses recorded from big-footed myotis (Myotis macrodactylus) bats as these animals searched for prey in five habitats differing in relative clutter level. Pulses were analyzed using ten parameters, including four structure-related characters which were derived by dividing each pulse into three elements based on two knees in the FM sweep. Results showed that overall frequency, pulse duration, and MR all varied across habitat. The strongest effects were found for MR in the body of the pulse, implying that this particular component plays a major role as M. macrodactylus, and potentially other bat species, adjust to varying clutter levels in their foraging habitats.

  12. [Possibilities of preventive therapy in frequent episodic tension-type headache].

    PubMed

    Tabeeva, G R; Fokina, N M

    2016-01-01

    To study the efficacy and safety of tenoten in the preventive treatment of frequent episodic tension-type headache (FETHA) compared to patients treated with pain relievers. A study included 60 patients with FETHA. Patients of the main group (n=30) received tenoten in addition to standard treatment. The study comprised 3 visits: beginning of treatment, after one month and after three months. All patients underwent physical and clinical/neurological examinations. In each visit, treatment efficacy was assessed according the following parameters: VAS scores (0-10) for assessment of pain and tension in pericranial muscles in 6 standard points, mean frequency and duration of the headache episode, quality of life indices, Beck depression scores, Spilberger trait and state anxiety, autonomic symptom severity, parameters of sleep disorders, frequency of adverse effects, CGI scores (0-7). Tenoten as a preventive medication reduced the frequency of headache episodes that allowed to diagnose patients with rare episodic tension-type headache in the end of treatment. At the same time, there was a significant reduction in headache intensity during the episode and decrease in amount of analgesics used by the patients.

  13. High-voltage electroencephalogram spindles in rats, aging and 5-HT2 antagonism.

    PubMed

    Moyanova, S; Kortenska, L; Kirov, R

    1998-03-09

    We examined the effects of serotonin-2 (5-hydroxytryptamine-2, 5-HT2) receptor antagonists on the so-called high-voltage spindles (HVS, electroencephalographic patterns, characterized by large amplitude rhythmic waves mainly in the alpha band), recorded from the frontal cortex of young, middle-aged and old freely-moving rats during waking immobility. The study was based on the assumption that the effects of 5-HT2 receptor antagonists on the HVS activity depend on the age of rats, because there is evidence for an age-related decrease in the 5-HT2 binding sites density. Four parameters of the electroencephalogram (EEG) were used to characterize the HVS activity: the square root-transformed EEG peak power in the alpha band, the frequency corresponding to this peak (both measured from the EEG power spectra using the fast Fourier transform), the HVS mean duration, and the HVS incidence (both measured from the EEG records). The EEG parameters were analyzed after i.p. administration of three 5-HT2 receptor antagonists: ketanserin, ritanserin and cyproheptadine. In young rats, the three drugs increased the alpha power, but did not change the alpha peak-corresponding frequency. Ketanserin and ritanserin did not change the HVS mean duration and HVS incidence, while cyproheptadine increased both these parameters in young rats. In middle-aged and old untreated rats, the HVS activity was significantly increased. The three 5-HT2 antagonists did not change the HVS activity in aged rats, which could be due to age-related suppression of the 5-HT2 receptor functions. Copyright 1998 Elsevier Science B.V.

  14. Duration estimates within a modality are integrated sub-optimally

    PubMed Central

    Cai, Ming Bo; Eagleman, David M.

    2015-01-01

    Perceived duration can be influenced by various properties of sensory stimuli. For example, visual stimuli of higher temporal frequency are perceived to last longer than those of lower temporal frequency. How does the brain form a representation of duration when each of two simultaneously presented stimuli influences perceived duration in different way? To answer this question, we investigated the perceived duration of a pair of dynamic visual stimuli of different temporal frequencies in comparison to that of a single visual stimulus of either low or high temporal frequency. We found that the duration representation of simultaneously occurring visual stimuli is best described by weighting the estimates of duration based on each individual stimulus. However, the weighting performance deviates from the prediction of statistically optimal integration. In addition, we provided a Bayesian account to explain a difference in the apparent sensitivity of the psychometric curves introduced by the order in which the two stimuli are displayed in a two-alternative forced-choice task. PMID:26321965

  15. Disaggregated seismic hazard and the elastic input energy spectrum: An approach to design earthquake selection

    NASA Astrophysics Data System (ADS)

    Chapman, Martin Colby

    1998-12-01

    The design earthquake selection problem is fundamentally probabilistic. Disaggregation of a probabilistic model of the seismic hazard offers a rational and objective approach that can identify the most likely earthquake scenario(s) contributing to hazard. An ensemble of time series can be selected on the basis of the modal earthquakes derived from the disaggregation. This gives a useful time-domain realization of the seismic hazard, to the extent that a single motion parameter captures the important time-domain characteristics. A possible limitation to this approach arises because most currently available motion prediction models for peak ground motion or oscillator response are essentially independent of duration, and modal events derived using the peak motions for the analysis may not represent the optimal characterization of the hazard. The elastic input energy spectrum is an alternative to the elastic response spectrum for these types of analyses. The input energy combines the elements of amplitude and duration into a single parameter description of the ground motion that can be readily incorporated into standard probabilistic seismic hazard analysis methodology. This use of the elastic input energy spectrum is examined. Regression analysis is performed using strong motion data from Western North America and consistent data processing procedures for both the absolute input energy equivalent velocity, (Vsbea), and the elastic pseudo-relative velocity response (PSV) in the frequency range 0.5 to 10 Hz. The results show that the two parameters can be successfully fit with identical functional forms. The dependence of Vsbea and PSV upon (NEHRP) site classification is virtually identical. The variance of Vsbea is uniformly less than that of PSV, indicating that Vsbea can be predicted with slightly less uncertainty as a function of magnitude, distance and site classification. The effects of site class are important at frequencies less than a few Hertz. The regression modeling does not resolve significant effects due to site class at frequencies greater than approximately 5 Hz. Disaggregation of general seismic hazard models using Vsbea indicates that the modal magnitudes for the higher frequency oscillators tend to be larger, and vary less with oscillator frequency, than those derived using PSV. Insofar as the elastic input energy may be a better parameter for quantifying the damage potential of ground motion, its use in probabilistic seismic hazard analysis could provide an improved means for selecting earthquake scenarios and establishing design earthquakes for many types of engineering analyses.

  16. QPO from the rapid burster

    NASA Astrophysics Data System (ADS)

    Dotani, T.

    1989-11-01

    Strong Quasi-Periodic Oscillations (QPO) in type 2 bursts from the rapid burster with Ginga were detected. The QPD have centroid frequency of approximately 5 and 2 Hz during bursts which lasted for approximately 10 and 30 sec, respectively. The QPO observations were analyzed and the following results were obtained: QPO centroid frequencies have some correlation with burst duration and peak count rate, however the correlations are complicated and the burst parameters do not uniquely determine the QPO centroid frequency; the appearance of the QPO is closely related to the so-called timescale-invariant profile of the bursts; the QPO are significant only in the even numbered peaks of the profile and not in the odd numbered peaks; in most cases the QPO centroid frequency decreases up to approximately 25 percent during a burst. The energy spectra at the QPO peaks and valleys were investigated and the QPO peaks were found to have significantely higher blackbody temperature than the QPD valleys.

  17. Geographic variations in the whistles of spinner dolphins (Stenella longirostris) of the Main Hawai‵ian Islands

    NASA Astrophysics Data System (ADS)

    Bazúa-Durán, Carmen; Au, Whitlow W. L.

    2004-12-01

    Geographic variations in the whistles of Hawai‵ian spinner dolphins are discussed by comparing 27 spinner dolphin pods recorded in waters off the Islands of Kaua‵i, O‵ahu, Lana‵i, and Hawai‵i. Three different behavioral states, the number of dolphins observed in each pod, and ten parameters extracted from each whistle contour were considered by using clustering and discriminant function analyses. The results suggest that spinner dolphin pods in the Main Hawai‵ian Islands share characteristics in approximately 48% of their whistles. Spinner dolphin pods had similar whistle parameters regardless of the island, location, and date when they were sampled and the dolphins' behavioral state and pod size. The term ‵‵whistle-specific subgroup'' (WSS) was used to designate whistle groups with similar whistles parameters (which could have been produced in part by the same dolphins). The emission rate of whistles was higher when spinner dolphins were socializing than when they were traveling or resting, suggesting that whistles are mainly used during close-range interactions. Spinner dolphins also seem to vary whistle duration according to their general behavioral state. Whistle duration and the number of turns and steps of a whistle may be more important in delivering information at the individual level than whistle frequency parameters. .

  18. Phylogenetic comparative analysis of electric communication signals in ghost knifefishes (Gymnotiformes: Apteronotidae).

    PubMed

    Turner, Cameron R; Derylo, Maksymilian; de Santana, C David; Alves-Gomes, José A; Smith, G Troy

    2007-12-01

    Electrocommunication signals in electric fish are diverse, easily recorded and have well-characterized neural control. Two signal features, the frequency and waveform of the electric organ discharge (EOD), vary widely across species. Modulations of the EOD (i.e. chirps and gradual frequency rises) also function as active communication signals during social interactions, but they have been studied in relatively few species. We compared the electrocommunication signals of 13 species in the largest gymnotiform family, Apteronotidae. Playback stimuli were used to elicit chirps and rises. We analyzed EOD frequency and waveform and the production and structure of chirps and rises. Species diversity in these signals was characterized with discriminant function analyses, and correlations between signal parameters were tested with phylogenetic comparative methods. Signals varied markedly across species and even between congeners and populations of the same species. Chirps and EODs were particularly evolutionarily labile, whereas rises differed little across species. Although all chirp parameters contributed to species differences in these signals, chirp amplitude modulation, frequency modulation (FM) and duration were particularly diverse. Within this diversity, however, interspecific correlations between chirp parameters suggest that mechanistic trade-offs may shape some aspects of signal evolution. In particular, a consistent trade-off between FM and EOD amplitude during chirps is likely to have influenced the evolution of chirp structure. These patterns suggest that functional or mechanistic linkages between signal parameters (e.g. the inability of electromotor neurons increase their firing rates without a loss of synchrony or amplitude of action potentials) constrain the evolution of signal structure.

  19. Generation of stable subfemtosecond hard x-ray pulses with optimized nonlinear bunch compression

    DOE PAGES

    Huang, Senlin; Ding, Yuantao; Huang, Zhirong; ...

    2014-12-15

    In this paper, we propose a simple scheme that leverages existing x-ray free-electron laser hardware to produce stable single-spike, subfemtosecond x-ray pulses. By optimizing a high-harmonic radio-frequency linearizer to achieve nonlinear compression of a low-charge (20 pC) electron beam, we obtain a sharp current profile possessing a few-femtosecond full width at half maximum temporal duration. A reverse undulator taper is applied to enable lasing only within the current spike, where longitudinal space charge forces induce an electron beam time-energy chirp. Simulations based on the Linac Coherent Light Source parameters show that stable single-spike x-ray pulses with a duration less thanmore » 200 attoseconds can be obtained.« less

  20. Stochastic extreme downscaling model for an assessment of changes in rainfall intensity-duration-frequency curves over South Korea using multiple regional climate models

    NASA Astrophysics Data System (ADS)

    So, Byung-Jin; Kim, Jin-Young; Kwon, Hyun-Han; Lima, Carlos H. R.

    2017-10-01

    A conditional copula function based downscaling model in a fully Bayesian framework is developed in this study to evaluate future changes in intensity-duration frequency (IDF) curves in South Korea. The model incorporates a quantile mapping approach for bias correction while integrated Bayesian inference allows accounting for parameter uncertainties. The proposed approach is used to temporally downscale expected changes in daily rainfall, inferred from multiple CORDEX-RCMs based on Representative Concentration Pathways (RCPs) 4.5 and 8.5 scenarios, into sub-daily temporal scales. Among the CORDEX-RCMs, a noticeable increase in rainfall intensity is observed in the HadGem3-RA (9%), RegCM (28%), and SNU_WRF (13%) on average, whereas no noticeable changes are observed in the GRIMs (-2%) for the period 2020-2050. More specifically, a 5-30% increase in rainfall intensity is expected in all of the CORDEX-RCMs for 50-year return values under the RCP 8.5 scenario. Uncertainty in simulated rainfall intensity gradually decreases toward the longer durations, which is largely associated with the enhanced strength of the relationship with the 24-h annual maximum rainfalls (AMRs). A primary advantage of the proposed model is that projected changes in future rainfall intensities are well preserved.

  1. Temperature Dependence of IP3-Mediated Local and Global Ca2+ Signals

    PubMed Central

    Dickinson, George D.; Parker, Ian

    2013-01-01

    We examined the effect of temperature (12–40°C) on local and global Ca2+ signals mediated by inositol trisphosphate receptor/channels (IP3R) in human neuroblastoma (SH-SY5Y) cells. The amplitudes and spatial spread of local signals arising from single IP3R (blips) and clusters of IP3R (puffs) showed little temperature dependence, whereas their kinetics (durations and latencies) were markedly accelerated by increasing temperature. In contrast, the amplitude of global Ca2+ waves increased appreciably at lower temperatures, probably as a result of the longer duration of IP3R channel opening. Several parameters, including puff and blip durations, puff latency and frequency, and frequency of repetitive Ca2+ waves, showed a biphasic temperature dependence on Arrhenius plots. In all cases the transition temperature occurred at ∼25°C, possibly reflecting a phase transition in the lipids of the endoplasmic reticulum membrane. Although the IP3-evoked Ca2+ signals were qualitatively similar at 25°C and 36°C, one should consider the temperature sensitivity of IP3-mediated signal amplitudes when extrapolating from room temperature to physiological temperature. Conversely, further cooling may be advantageous to improve the optical resolution of channel gating kinetics. PMID:23442860

  2. Alveolar and Postalveolar Voiceless Fricative and Affricate Productions of Spanish–English Bilingual Children With Cochlear Implants

    PubMed Central

    Bunta, Ferenc; Tomblin, J. Bruce

    2017-01-01

    Purpose This study investigates the production of voiceless alveolar and postalveolar fricatives and affricates by bilingual and monolingual children with hearing loss who use cochlear implants (CIs) and their peers with normal hearing (NH). Method Fifty-four children participated in our study, including 12 Spanish–English bilingual CI users (M = 6;0 [years;months]), 12 monolingual English-speaking children with CIs (M = 6;1), 20 bilingual children with NH (M = 6;5), and 10 monolingual English-speaking children with NH (M = 5;10). Picture elicitation targeting /s/, /tʃ/, and /ʃ/ was administered. Repeated-measures analyses of variance comparing group means for frication duration, rise time, and centroid frequency were conducted for the effects of CI use and bilingualism. Results All groups distinguished the target sounds in the 3 acoustic parameters examined. Regarding frication duration and rise time, the Spanish productions of bilingual children with CIs differed from their bilingual peers with NH. English frication duration patterns for bilingual versus monolingual CI users also differed. Centroid frequency was a stronger place cue for children with NH than for children with CIs. Conclusion Patterns of fricative and affricate production display effects of bilingualism and diminished signal, yielding unique patterns for bilingual and monolingual CI users. PMID:28800372

  3. Source parameters of the 1999 Osa peninsula (Costa Rica) earthquake sequence from spectral ratios analysis

    NASA Astrophysics Data System (ADS)

    Verdecchia, A.; Harrington, R. M.; Kirkpatrick, J. D.

    2017-12-01

    Many observations suggest that duration and size scale in a self-similar way for most earthquakes. Deviations from the expected scaling would suggest that some physical feature on the fault surface influences the speed of rupture differently at different length scales. Determining whether differences in scaling exist between small and large earthquakes is complicated by the fact that duration estimates of small earthquakes are often distorted by travel-path and site effects. However, when carefully estimated, scaling relationships between earthquakes may provide important clues about fault geometry and the spatial scales over which it affects fault rupture speed. The Mw 6.9, 20 August 1999, Quepos earthquake occurred on the plate boundary thrust fault along southern Costa Rica margin where the subducting seafloor is cut by numerous normal faults. The mainshock and aftershock sequence were recorded by land and (partially by) ocean bottom (OBS) seismic arrays deployed as part of the CRSEIZE experiment. Here we investigate the size-duration scaling of the mainshock and relocated aftershocks on the plate boundary to determine if a change in scaling exists that is consistent with a change in fault surface geometry at a specific length scale. We use waveforms from 5 short-period land stations and 12 broadband OBS stations to estimate corner frequencies (the inverse of duration) and seismic moment for several aftershocks on the plate interface. We first use spectral amplitudes of single events to estimate corner frequencies and seismic moments. We then adopt a spectral ratio method to correct for non-source-related effects and refine the corner frequency estimation. For the spectral ratio approach, we use pairs of earthquakes with similar waveforms (correlation coefficient > 0.7), with waveform similarity implying event co-location. Preliminary results from single spectra show similar corner frequency values among events of 0.5 ≤ M ≤ 3.6, suggesting a decrease in static stress drop with magnitude. Our next step is to refine corner frequency estimates using spectral ratios to see if the trend in corner frequency persists with small events, and to extend the magnitude range of the estimations using land-based recordings of the mainshock and two largest aftershocks, which occurred prior to the Osa array deployment.

  4. Effect of rajyoga meditation on chronic tension headache.

    PubMed

    Kiran; Girgla, Kawalinder K; Chalana, Harsh; Singh, Harjot

    2014-01-01

    Chronic tension-type headache (CTTH) is the most common type of headache with no truly effective treatment. This study was designed to correlate the additive effect of meditation on CTTH patients receiving medical treatment. 50 patients (aged 18-58 years) presenting with a clinical diagnosis of CCTH, were divided in 2 groups. Group 1 (n=30) received 8 lessons and practical demonstration of Brahmakumaris spiritual based meditation known as Rajyoga meditation for relaxation therapy, in addition to routine medical treatment (analgesics and muscle relaxants). Group 2 (n=20) patients received analgesics and muscle relaxants twice a day but no relaxation therapy in the form of meditation. Both groups were followed up for 8 weeks period. The parameters studied were severity, frequency and duration of CCTH, and their headache index calculated. Patients in both groups showed a highly significant reduction in headache variables (P<0.001) after 8 weeks. But the percentage of patients showing highly significant relief in severity of headache, duration & frequency in Group 1 was 94%, 91% and 97% respectively whereas in Group 2 it was 36%, 36% and 49% respectively. Headache relief as calculated by headache index was 99% in Group 1 as compared to 51% in Group 2. Even Short term spiritual based relaxation therapy (Rajyoga meditation) was highly effective in causing earlier relief in chronic tension headache as measured by headache parameter.

  5. A study of deterioration of pulmonary function parameters among smokers and recovery among ex-smokers in bus depot workers.

    PubMed

    Sreenivas, B Sudha; Sunitha, M S; Nataraj, S M; Dhar, Murali

    2012-01-01

    Smoking has deleterious effects on Pulmonary Function Test (PFT) parameters; however, evidences about recovery in ex-smokers are ambiguous. Therefore present study was conducted to quantify relative deterioration of PFT parameters and to assess reversibility of the same. A cross-sectional study was conducted on 84 bus-depot workers consisting of equal number of smokers, ex-smokers and non-smokers. PFT observations were obtained using Medspiror following standard methods and precautions. Comparisons among three groups were performed employing one-way ANOVA and post-hoc tests. There were substantial effects of smoking on PFT parameters (deterioration was up-to half). Partial recovery was found in all the parameters of ex-smokers. Frequency and duration of smoking were negatively correlated with some of the parameters. In conclusion, present study has demonstrated considerable deterioration of PFT parameters in smokers and indications of recovery in ex-smokers. Further detailed study with larger sample size and stricter definition of ex-smokers is recommended.

  6. Sleep patterns and insomnia among adolescents: a population-based study.

    PubMed

    Hysing, Mari; Pallesen, Ståle; Stormark, Kjell M; Lundervold, Astri J; Sivertsen, Børge

    2013-10-01

    The aim of the current study was to examine sleep patterns and rates of insomnia in a population-based study of adolescents aged 16-19 years. Gender differences in sleep patterns and insomnia, as well as a comparison of insomnia rates according to DSM-IV, DSM-V and quantitative criteria for insomnia (Behav. Res. Ther., 41, 2003, 427), were explored. We used a large population-based study in Hordaland county in Norway, conducted in 2012. The sample included 10,220 adolescents aged 16-18 years (54% girls). Self-reported sleep measurements included bedtime, rise time, time in bed, sleep duration, sleep efficiency, sleep onset latency, wake after sleep onset, rate and frequency and duration of difficulties initiating and maintaining sleep and rate and frequency of tiredness and sleepiness. The adolescents reported short sleep duration on weekdays (mean 6:25 hours), resulting in a sleep deficiency of about 2 h. A majority of the adolescents (65%) reported sleep onset latency exceeding 30 min. Girls reported longer sleep onset latency and a higher rate of insomnia than boys, while boys reported later bedtimes and a larger weekday-weekend discrepancy on several sleep parameters. Insomnia prevalence rates ranged from a total prevalence of 23.8 (DSM-IV criteria), 18.5 (DSM-V criteria) and 13.6% (quantitative criteria for insomnia). We conclude that short sleep duration, long sleep onset latency and insomnia were prevalent in adolescents. This warrants attention as a public health concern in this age group. © 2013 European Sleep Research Society.

  7. The limits of applicability of the sound exposure level (SEL) metric to temporal threshold shifts (TTS) in beluga whales, Delphinapterus leucas.

    PubMed

    Popov, Vladimir V; Supin, Alexander Ya; Rozhnov, Viatcheslav V; Nechaev, Dmitry I; Sysueva, Evgenia V

    2014-05-15

    The influence of fatiguing sound level and duration on post-exposure temporary threshold shift (TTS) was investigated in two beluga whales (Delphinapterus leucas). The fatiguing sound was half-octave noise with a center frequency of 22.5 kHz. TTS was measured at a test frequency of 32 kHz. Thresholds were measured by recording rhythmic evoked potentials (the envelope following response) to a test series of short (eight cycles) tone pips with a pip rate of 1000 s(-1). TTS increased approximately proportionally to the dB measure of both sound pressure (sound pressure level, SPL) and duration of the fatiguing noise, as a product of these two variables. In particular, when the noise parameters varied in a manner that maintained the product of squared sound pressure and time (sound exposure level, SEL, which is equivalent to the overall noise energy) at a constant level, TTS was not constant. Keeping SEL constant, the highest TTS appeared at an intermediate ratio of SPL to sound duration and decreased at both higher and lower ratios. Multiplication (SPL multiplied by log duration) better described the experimental data than an equal-energy (equal SEL) model. The use of SEL as a sole universal metric may result in an implausible assessment of the impact of a fatiguing sound on hearing thresholds in odontocetes, including under-evaluation of potential risks. © 2014. Published by The Company of Biologists Ltd.

  8. Oscillatory fluid flow induces the osteogenic lineage commitment of mesenchymal stem cells: The effect of shear stress magnitude, frequency, and duration.

    PubMed

    Stavenschi, Elena; Labour, Marie-Noelle; Hoey, David A

    2017-04-11

    A potent regulator of bone anabolism is physical loading. However, it is currently unclear whether physical stimuli such as fluid shear within the marrow cavity is sufficient to directly drive the osteogenic lineage commitment of resident mesenchymal stem cells (MSC). Therefore, the objective of the study is to employ a systematic analysis of oscillatory fluid flow (OFF) parameters predicted to occur in vivo on early MSC osteogenic responses and late stage lineage commitment. MSCs were exposed to OFF of 1Pa, 2Pa and 5Pa magnitudes at frequencies of 0.5Hz, 1Hz and 2Hz for 1h, 2h and 4h of stimulation. Our findings demonstrate that OFF elicits a positive osteogenic response in MSCs in a shear stress magnitude, frequency, and duration dependent manner that is gene specific. Based on the mRNA expression of osteogenic markers Cox2, Runx2 and Opn after short-term fluid flow stimulation, we identified that a regime of 2Pa shear magnitude and 2Hz frequency induces the most robust and reliable upregulation in osteogenic gene expression. Furthermore, long-term mechanical stimulation utilising this regime, elicits a significant increase in collagen and mineral deposition when compared to static control demonstrating that mechanical stimuli predicted within the marrow is sufficient to directly drive osteogenesis. Copyright © 2017. Published by Elsevier Ltd.

  9. Regional Frequency and Uncertainty Analysis of Extreme Precipitation in Bangladesh

    NASA Astrophysics Data System (ADS)

    Mortuza, M. R.; Demissie, Y.; Li, H. Y.

    2014-12-01

    Increased frequency of extreme precipitations, especially those with multiday durations, are responsible for recent urban floods and associated significant losses of lives and infrastructures in Bangladesh. Reliable and routinely updated estimation of the frequency of occurrence of such extreme precipitation events are thus important for developing up-to-date hydraulic structures and stormwater drainage system that can effectively minimize future risk from similar events. In this study, we have updated the intensity-duration-frequency (IDF) curves for Bangladesh using daily precipitation data from 1961 to 2010 and quantified associated uncertainties. Regional frequency analysis based on L-moments is applied on 1-day, 2-day and 5-day annual maximum precipitation series due to its advantages over at-site estimation. The regional frequency approach pools the information from climatologically similar sites to make reliable estimates of quantiles given that the pooling group is homogeneous and of reasonable size. We have used Region of influence (ROI) approach along with homogeneity measure based on L-moments to identify the homogenous pooling groups for each site. Five 3-parameter distributions (i.e., Generalized Logistic, Generalized Extreme value, Generalized Normal, Pearson Type Three, and Generalized Pareto) are used for a thorough selection of appropriate models that fit the sample data. Uncertainties related to the selection of the distributions and historical data are quantified using the Bayesian Model Averaging and Balanced Bootstrap approaches respectively. The results from this study can be used to update the current design and management of hydraulic structures as well as in exploring spatio-temporal variations of extreme precipitation and associated risk.

  10. Application of flood-intensity-duration curve, rainfall-intensity-duration curve and time of concentration to analyze the pattern of storms and their corresponding floods for the natural flood events

    NASA Astrophysics Data System (ADS)

    Kim, Nam Won; Shin, Mun-Ju; Lee, Jeong Eun

    2016-04-01

    The analysis of storm effects on floods is essential step for designing hydraulic structure and flood plain. There are previous studies for analyzing the relationship between the storm patterns and peak flow, flood volume and durations for various sizes of the catchments, but they are not enough to analyze the natural storm effects on flood responses quantitatively. This study suggests a novel method of quantitative analysis using unique factors extracted from the time series of storms and floods to investigate the relationship between natural storms and their corresponding flood responses. We used a distributed rainfall-runoff model of Grid based Rainfall-runoff Model (GRM) to generate the simulated flow and areal rainfall for 50 catchments in Republic of Korea size from 5.6 km2 to 1584.2 km2, which are including overlapped dependent catchments and non-overlapped independent catchments. The parameters of the GRM model were calibrated to get the good model performances of Nash-Sutcliffe efficiency. Then Flood-Intensity-Duration Curve (FIDC) and Rainfall-Intensity-Duration Curve (RIDC) were generated by Flood-Duration-Frequency and Intensity-Duration-Frequency methods respectively using the time series of hydrographs and hyetographs. Time of concentration developed for the Korea catchments was used as a consistent measure to extract the unique factors from the FIDC and RIDC over the different size of catchments. These unique factors for the storms and floods were analyzed against the different size of catchments to investigate the natural storm effects on floods. This method can be easily used to get the intuition of the natural storm effects with various patterns on flood responses. Acknowledgement This research was supported by a grant (11-TI-C06) from Advanced Water Management Research Program funded by Ministry of Land, Infrastructure and Transport of Korean government.

  11. Associations between self-reported sleep duration and sleeping disorder with concentrations of fasting and 2-h glucose, insulin, and glycosylated hemoglobin among adults without diagnosed diabetes.

    PubMed

    Ford, Earl S; Wheaton, Anne G; Chapman, Daniel P; Li, Chaoyang; Perry, Geraldine S; Croft, Janet B

    2014-07-01

    There is limited information from population-based investigations of the associations between sleep duration and sleep disorders and parameters of glucose homeostasis. The objective of the present study was to examine cross-sectional associations between sleep duration and sleep disordered breathing with concentrations of insulin, fasting and 2-h glucose, and HbA1c. Data from 11 815 adults aged ≥20 years without diagnosed diabetes (5002 with an oral glucose tolerance test) from the National Health and Nutrition Examination Survey 2005-2010 were used. Information about sleep duration (2005-2010) and sleep apnea and sleep-disordered breathing (2005-2008) was obtained via questionnaire. An estimated 36.0% of participants reported sleeping ≤6 h/night, 62.0% reported sleeping 7-9 h/night, and 2.0% reported sleeping ≥10 h/night. In 2005-2008, 33.0% reported snoring ≥5 nights per week, 5.9% reported they snorted, gasped, or stopped breathing ≥5 nights/week, and 4.2% reported sleep apnea. Sleep duration was significantly associated with fasting concentrations of insulin and concentrations of HbA1c only in models that did not adjust for body mass index (BMI). Concentrations of fasting and 2-h glucose were significantly associated with sleep duration in models that adjusted only for age. Snoring frequency was positively associated with concentrations of insulin and HbA1c. Frequency of snorting or stopping breathing and sleep apnea status were associated with concentrations of insulin and of HbA1c only when BMI was not accounted for. In a representative sample of US adults, concentrations of insulin and HbA1c were significantly associated with short sleep duration, possibly mediated by BMI. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.

  12. Effects of reducing the frequency and duration criteria for binge eating on lifetime prevalence of bulimia nervosa and binge eating disorder: implications for DSM-5.

    PubMed

    Trace, Sara E; Thornton, Laura M; Root, Tammy L; Mazzeo, Suzanne E; Lichtenstein, Paul; Pedersen, Nancy L; Bulik, Cynthia M

    2012-05-01

    We assessed the impact of reducing the binge eating frequency and duration thresholds on the diagnostic criteria for bulimia nervosa (BN) and binge eating disorder (BED). We estimated the lifetime population prevalence of BN and BED in 13,295 female twins from the Swedish Twin study of Adults: Genes and Environment employing a range of frequency and duration thresholds. External validation (risk to cotwin) was used to investigate empirical evidence for an optimal binge eating frequency threshold. The lifetime prevalence estimates of BN and BED increased linearly as the frequency criterion decreased. As the required duration increased, the prevalence of BED decreased slightly. Discontinuity in cotwin risk was observed in BN between at least four times per month and at least five times per month. This model could not be fit for BED. The proposed changes to the DSM-5 binge eating frequency and duration criteria would allow for better detection of binge eating pathology without resulting in a markedly higher lifetime prevalence of BN or BED. Copyright © 2011 Wiley Periodicals, Inc.

  13. Effects of single cycle binaural beat duration on auditory evoked potentials.

    PubMed

    Mihajloski, Todor; Bohorquez, Jorge; Özdamar, Özcan

    2014-01-01

    Binaural beat (BB) illusions are experienced as continuous central pulsations when two sounds with slightly different frequencies are delivered to each ear. It has been shown that steady-state auditory evoked potentials (AEPs) to BBs can be captured and investigated. The authors recently developed a new method of evoking transient AEPs to binaural beats using frequency modulated stimuli. This methodology was able to create single BBs in predetermined intervals with varying carrier frequencies. This study examines the effects of the BB duration and the frequency modulating component of the stimulus on the binaural beats and their evoked potentials. Normal hearing subjects were tested with a set of four durations (25, 50, 100, and 200 ms) with two stimulation configurations, binaural dichotic (binaural beats) and diotic (frequency modulation). The results obtained from the study showed that out of the given durations, the 100 ms beat, was capable of evoking the largest amplitude responses. The frequency modulation effect showed a decrease in peak amplitudes with increasing beat duration until their complete disappearance at 200 ms. Even though, at 200 ms, the frequency modulation effects were not present, the binaural beats were still perceived and captured as evoked potentials.

  14. Investigation of statistical parameters of the evolving wind wave field using a laser slope gauge

    NASA Astrophysics Data System (ADS)

    Zavadsky, A.; Shemer, L.

    2017-05-01

    Statistical parameters of water waves generated by wind in a small scale facility are studied using extensively a Laser Slope Gauge (LSG), in addition to conventional measuring instruments such as a wave gauge and Pitot tube. The LSG enables direct measurements of two components of the instantaneous surface slope. Long sampling duration in a relatively small experimental facility allowed accumulating records of the measured parameters containing a large number of waves. Data were accumulated for a range of wind velocities at multiple fetches. Frequency spectra of the surface elevation and of the instantaneous local slope variation measured under identical conditions are compared. Higher moments of the surface slope are presented. Information on the waves' asymmetry is retrieved from the computed skewness of the surface slope components.

  15. [Physiological basis of a possible increase in the efficacy of the photo- and magnetotherapy of the visual nerve upon partial atrophy and ischemia].

    PubMed

    Shlygin, V V; Tiuliaev, A P; Ioĭleva, E E; Maksimov, G V

    2004-01-01

    An approach to the choice of the parameters of physiotherapeutic and biophysical influence on the visual nerve was proposed. The approach is based on parallel photo- and magnetostimulation of excitable fibers in which the morphological and electrophysiological properties of fibers and some parameters of the pathological processes associated with partial artophy and ischemia are taken into account. A method for correlating the photostimulation by light flashes (intensity 65 mWt at emission wavelength 660 nm) of a portion of the retina with the choice of the parameters of magnetic influence (amplitude 73 mT, duration of the wave front of 40 ms, and frequency of pulse sequence of about 1 Hz) on the visual nerve was developed.

  16. The Association between Outpatient Buprenorphine Detoxification Duration and Clinical Treatment Outcomes: A Review

    PubMed Central

    Sigmon, Stacey C.; Strain, Eric C.; Heil, Sarah H.; Higgins, Stephen T.

    2011-01-01

    Background The association between buprenorphine taper duration and treatment outcomes is not well understood. This review evaluated whether duration of outpatient buprenorphine taper is significantly associated with treatment outcomes. Methods Studies that were published in peer-reviewed journals, administered buprenorphine as an outpatient taper to opioid-dependent participants, and provided data on at least one of three primary treatment outcome measures (opioid abstinence, retention, peak withdrawal severity) were reviewed. Primary treatment outcomes were evaluated as a function of taper duration using hierarchical linear regressions using pre-taper maintenance as a cofactor. Results Twenty-eight studies were reviewed. Taper duration significantly predicted percent of opioid-negative samples provided during treatment, however pre-taper maintenance period predicted percent participants abstinent on the final day of treatment. High rates of relapse were reported. No significant association between taper duration and retention in treatment or peak withdrawal severity was observed. Conclusion The data reviewed here suggest taper duration is associated with opioid abstinence achieved during detoxification but not with other markers of treatment outcome. The reviewed studies varied widely on several parameters (e.g., frequency of urinalysis testing, provision of ancillary medications) that may influence treatment outcome and thus could have interfered with the ability to identify relationships between taper duration and outcomes. Future studies evaluating opioid detoxification should utilize rigorous experimental methods and report a wider range of outcome measures in order to help advance our understanding of the association between taper duration and treatment outcomes. PMID:21741781

  17. Patterns of daily duration and frequency of breastfeeding among exclusively breastfed infants in Shiraz, Iran, a 6-month follow-up study using Bayesian generalized linear mixed models.

    PubMed

    Saki, Azadeh; Eshraghian, Mohammad Reza; Tabesh, Hamed

    2012-12-19

    Despite numerous studies on the benefits of exclusive breastfeeding during the first half year of life, little information is available on actual breastfeeding practices in terms of daily duration and frequency of suckling. This study proposes to determine daily breastfeeding patterns among exclusively breastfed infants from birth to six months. An observational prospective follow-up study of daily feeding practices among exclusively breastfed infants was conducted in 2007/2008. Mothers were recruited and interviewed during their first month postpartum health center visit. A total of 287 mothers were recruited into the study. Primary outcome measures were suckling duration and frequency of breastfeeding during daytime and nighttime. Mothers were asked at each healthcare visit to report the daily duration in minutes and the daily number of breastfeeding sessions. Mixed models were used to determine breastfeeding patterns and predictors. Of 287 mothers selected for this study, 174 (61%) exclusively breastfeeding until six months after delivery. Mixed modeling showed that as the infant's age increased duration of one suckling, cumulative duration and frequency of breastfeeding during daytime, nighttime and a twenty four hour period all gradually decreased. Infants gender and receiving professional advice about breastfeeding were also significant factors in breastfeeding patterns (p<0.05). The one suckling duration and frequency of feeds in this study population were considerably higher than values reported in other populations. The variation of feeding patterns between exclusively breastfed infants was very wide. The distributions of one suckling duration, frequency of breastfeeding and cumulative duration of feeds were right-skewed. The current professional advices about breastfeeding are not appropriate because they do not consider unique condition within specific populations.

  18. Flood frequencies and durations and their response to El Niño Southern Oscillation: Global analysis

    NASA Astrophysics Data System (ADS)

    Ward, P. J.; Kummu, M.; Lall, U.

    2016-08-01

    Floods are one of the most serious forms of natural hazards in terms of the damages they cause. In 2012 alone, flood damages exceeded 19 billion. A large proportion of the damages from several recent major flood disasters, such as those in South India and South Carolina (2015), England and Wales (2014), the Mississippi (2012), Thailand (2011), Queensland (Australia) (2010-2011), and Pakistan (2010), were related to the long duration of those flood events. However, most flood risk studies to date do not account for flood duration. In this paper, we provide the first global modelling exercise to assess the link between interannual climate variability and flood duration and frequency. Specifically, we examine relationships between simulated flood events and El Niño Southern Oscillation (ENSO). Our results show that the duration of flooding appears to be more sensitive to ENSO than is the case for flood frequency. At the globally aggregated scale, we found floods to be significantly longer during both El Niño and La Niña years, compared to neutral years. At the scale of individual river basins, we found strong correlations between ENSO and both flood frequency and duration for a large number of basins, with generally stronger correlations for flood duration than for flood frequency. Future research on flood impacts should attempt to incorporate more information on flood durations.

  19. The P Wave Time-Frequency Variability Reflects Atrial Conduction Defects before Paroxysmal Atrial Fibrillation.

    PubMed

    Alcaraz, Raúl; Martínez, Arturo; Rieta, José J

    2015-09-01

    The study of atrial conduction defects associated with the onset of paroxysmal atrial fibrillation (PAF) can be addressed by analyzing the P wave from the surface electrocardiogram (ECG). Traditionally, signal-averaged ECGs have been mostly used for this purpose. However, this alternative hinders the possibility to quantify every single P wave, its variability over time, as well as to obtain complimentary and evolving information about the arrhythmia. This work analyzes the time progression of several time and frequency P wave features as potential indicators of atrial conduction variability several hours preceding the onset of PAF. The longest sinus rhythm interval from 24-hour Holter recordings of 46 PAF patients was selected. Next, the 2 hours before the onset of PAF were extracted and divided into two 1-hour periods. Every single P wave was automatically delineated and characterized by 16 time and frequency metrics, such as its duration, absolute energy in several frequency bands and high-to-low-frequency energy ratios. Finally, the P wave variability over each 1-hour period was estimated from the 16 features making use of a least-squares linear fitting. As a reference, the same parameters were also estimated from a set of 1-hour ECG segments randomly chosen from a control group of 53 healthy subjects age-, gender-, and heart rate-matched. All the analyzed metrics provided an increasing P wave variability trend as the onset of PAF approximated, being P wave duration and P wave high-frequency energy the most significant individual metrics. The linear fitting slope α associated with P wave duration was (2.48 ± 1.98)×10(-2) for healthy subjects, (23.8 ± 14.1)×10(-2) for ECG segments far from PAF and for (81.8 ± 48.7)×10(-2) ECG segments close to PAF p = 6.96×10(-22) . Similarly, the P wave high-frequency energy linear fitting slope was (2.42 ± 4.97)×10(-9) , (54.2 ± 107.1)×10(-9) and (274.2 ± 566.1)×10(-9) , respectively (p = 2.85×10(-20) ). A univariate discriminant analysis provided that both P wave duration and P wave high-frequency energy could discern among the three ECG sets with diagnostic ability around 80%, which was improved up to 88% by combining these metrics in a multivariate discriminant analysis. Alterations in atrial conduction can be successfully quantified several hours before the onset of PAF by estimating variability over time of several time and frequency P wave features. © 2014 Wiley Periodicals, Inc.

  20. Effects of fish size and temperature on weakfish disturbance calls: implications for the mechanism of sound generation.

    PubMed

    Connaughton, M A; Taylor, M H; Fine, M L

    2000-05-01

    To categorize variation in disturbance calls of the weakfish Cynoscion regalis and to understand their generation, we recorded sounds produced by different-sized fish, and by similar-sized fish at different temperatures, as well as muscle electromyograms. Single, simultaneous twitches of the bilateral sonic muscles produce a single sound pulse consisting of a two- to three-cycle acoustic waveform. Typical disturbance calls at 18 degrees C consist of trains of 2-15 pulses with a sound pressure level (SPL) of 74 dB re 20 microPa at 10 cm, a peak frequency of 540 Hz, a repetition rate of 20 Hz and a pulse duration of 3.5 ms. The pulse duration suggests an incredibly short twitch time. Sound pressure level (SPL) and pulse duration increase and dominant frequency decreases in larger fish, whereas SPL, repetition rate and dominant frequency increase and pulse duration decreases with increasing temperature. The dominant frequency is inversely related to pulse duration and appears to be determined by the duration of muscle contraction. We suggest that the lower dominant frequency of larger fish is caused by a longer pulse (=longer muscle twitch) and not by the lower resonant frequency of a larger swimbladder.

  1. A simple model for strong ground motions and response spectra

    USGS Publications Warehouse

    Safak, Erdal; Mueller, Charles; Boatwright, John

    1988-01-01

    A simple model for the description of strong ground motions is introduced. The model shows that response spectra can be estimated by using only four parameters of the ground motion, the RMS acceleration, effective duration and two corner frequencies that characterize the effective frequency band of the motion. The model is windowed band-limited white noise, and is developed by studying the properties of two functions, cumulative squared acceleration in the time domain, and cumulative squared amplitude spectrum in the frequency domain. Applying the methods of random vibration theory, the model leads to a simple analytical expression for the response spectra. The accuracy of the model is checked by using the ground motion recordings from the aftershock sequences of two different earthquakes and simulated accelerograms. The results show that the model gives a satisfactory estimate of the response spectra.

  2. Historical and future drought in Bangladesh using copula-based bivariate regional frequency analysis

    NASA Astrophysics Data System (ADS)

    Mortuza, Md Rubayet; Moges, Edom; Demissie, Yonas; Li, Hong-Yi

    2018-02-01

    The study aims at regional and probabilistic evaluation of bivariate drought characteristics to assess both the past and future drought duration and severity in Bangladesh. The procedures involve applying (1) standardized precipitation index to identify drought duration and severity, (2) regional frequency analysis to determine the appropriate marginal distributions for both duration and severity, (3) copula model to estimate the joint probability distribution of drought duration and severity, and (4) precipitation projections from multiple climate models to assess future drought trends. Since drought duration and severity in Bangladesh are often strongly correlated and do not follow same marginal distributions, the joint and conditional return periods of droughts are characterized using the copula-based joint distribution. The country is divided into three homogeneous regions using Fuzzy clustering and multivariate discordancy and homogeneity measures. For given severity and duration values, the joint return periods for a drought to exceed both values are on average 45% larger, while to exceed either value are 40% less than the return periods from the univariate frequency analysis, which treats drought duration and severity independently. These suggest that compared to the bivariate drought frequency analysis, the standard univariate frequency analysis under/overestimate the frequency and severity of droughts depending on how their duration and severity are related. Overall, more frequent and severe droughts are observed in the west side of the country. Future drought trend based on four climate models and two scenarios showed the possibility of less frequent drought in the future (2020-2100) than in the past (1961-2010).

  3. [Application of high frequency electric welding in adrenal surgery. Current state and prospects].

    PubMed

    Kvacheniuk, A N; Suprun, I S; Negrienko, K V; Barenfel'd, A I; Datta, M R; Datta, L R; Nelep, A D

    2012-07-01

    In 14 patients underwent open adrenalectomy with high-frequency electric welding application (I group), in 8 - open adrenalectomy (II group). The two groups were compared: duration of surgery, blood loss, postoperative pain intensity, duration of postoperative hospitalization, the frequency of intra-and postoperative complications, histological changes in tissues. The advantages of open adrenalectomy with high-frequency electric welding application feel less duration of surgery and estimated blood loss, lack of necrosis in the surrounding tissues and foreign bodies in the wound, reducing the trauma of surgery, improving rehabilitation.

  4. Laser stripping of hydrogen atoms by direct ionization

    DOE PAGES

    Brunetti, E.; Becker, W.; Bryant, H. C.; ...

    2015-05-08

    Direct ionization of hydrogen atoms by laser irradiation is investigated as a potential new scheme to generate proton beams without stripping foils. The time-dependent Schrödinger equation describing the atom-radiation interaction is numerically solved obtaining accurate ionization cross-sections for a broad range of laser wavelengths, durations and energies. Parameters are identified where the Doppler frequency up-shift of radiation colliding with relativistic particles can lead to efficient ionization over large volumes and broad bandwidths using currently available lasers.

  5. Laser stripping of hydrogen atoms by direct ionization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brunetti, E.; Becker, W.; Bryant, H. C.

    Direct ionization of hydrogen atoms by laser irradiation is investigated as a potential new scheme to generate proton beams without stripping foils. The time-dependent Schrödinger equation describing the atom-radiation interaction is numerically solved obtaining accurate ionization cross-sections for a broad range of laser wavelengths, durations and energies. Parameters are identified where the Doppler frequency up-shift of radiation colliding with relativistic particles can lead to efficient ionization over large volumes and broad bandwidths using currently available lasers.

  6. Hydratools manual version 1.0, documentation for a MATLAB®-based post-processing package for the Sontek Hydra

    USGS Publications Warehouse

    Martini, Marinna A.; Sherwood, Chris; Horwitz, Rachel; Ramsey, Andree; Lightsom, Fran; Lacy, Jessie; Xu, Jingping

    2006-01-01

    3.\tpreserving minimally processed and partially processed versions of data sets. STG usually deploys ADV and PCADP probes configured as downward looking, mounted on bottom tripods, with the objective of measuring high-resolution near-bed currents. The velocity profiles are recorded with minimal internal data processing. Also recorded are parameters such as temperature, conductivity, optical backscatter, light transmission, and high frequency pressure. Sampling consists of high-frequency bursts(1–10 Hz) bursts of long duration (5–30 minutes) at regular and recurring intervals for a duration of 1 to 6 months. The result is very large data files, often 500 MB per Hydra, per deployment, in Sontek's compressed binary format. This section introduces the Hydratools toolbox and provides information about the history of the system's development. The USGS philosophy regarding data quality is discussed to provide an understating of the motivation for creating the system. General information about the following topics will also be discussed: hardware and software required for the system, basic processing steps, limitations of program usage, and features that are unique to the programs.

  7. Significant events in low-level flow conditions hazardous to aircraft

    NASA Technical Reports Server (NTRS)

    Alexander, M. B.; Camp, D. W.

    1983-01-01

    Atmospheric parameters recorded during high surface winds are analyzed to determine magnitude, frequency, duration, and simultaneity of occurrence of low level flow conditions known to be hazardous to the ascent and descent of conventional aircraft and the space shuttle. Graphic and tabular presentations of mean and extreme values and simultaneous occurrences of turbulence (gustiness and a gust factor), wind shear (speed and direction), and vertical motion (updrafts and downdrafts), along with associated temperature inversions are included as function of tower height, layer and/or distance for six 5 sec intervals (one interval every 100 sec) of parameters sampled simultaneously at the rate of 10 speeds, directions and temperatures per second during an approximately 10 min period.

  8. Nurse dose: what's in a concept?

    PubMed

    Manojlovich, Milisa; Sidani, Souraya

    2008-08-01

    Many researchers have sought to address the relationship between nursing care and patient outcomes, with inconsistent and contradictory findings. We conducted a concept analysis and concept derivation, basing our work on theoretical and empirical literature, to derive nurse dose as a concept that pulls into a coherent whole disparate variables used in staffing studies. We defined nurse dose as the level of nursing reflected in the purity, amount, frequency, and duration of nursing care needed to produce favorable outcomes. All four parameters of nurse dose used together can facilitate our understanding of how nursing contributes to patient outcomes. Ongoing investigation will help to identify the parameters of nurse dose that have the greatest effect on outcomes. 2008 Wiley Periodicals, Inc

  9. Differences between vocalization evoked by social stimuli in feral cats and house cats.

    PubMed

    Yeon, Seong C; Kim, Young K; Park, Se J; Lee, Scott S; Lee, Seung Y; Suh, Euy H; Houpt, Katherine A; Chang, Hong H; Lee, Hee C; Yang, Byung G; Lee, Hyo J

    2011-06-01

    To investigate how socialization can affect the types and characteristics of vocalization produced by cats, feral cats (n=25) and house cats (n=13) were used as subjects, allowing a comparison between cats socialized to people and non-socialized cats. To record vocalization and assess the cats' responses to behavioural stimuli, five test situations were used: approach by a familiar caretaker, by a threatening stranger, by a large doll, by a stranger with a dog and by a stranger with a cat. Feral cats showed extremely aggressive and defensive behaviour in most test situations, and produced higher call rates than those of house cats in the test situations, which could be attributed to less socialization to other animals and to more sensitivity to fearful situations. Differences were observed in the acoustic parameters of feral cats in comparison to those of house cats. The feral cat produced significantly higher frequency in fundamental frequency, peak frequency, 1st quartile frequency, 3rd quartile frequency of growls and hisses in agonistic test situations. In contrast to the growls and hisses, in meow, all acoustic parameters like fundamental frequency, first formant, peak frequency, 1st quartile frequency, and 3rd quartile frequency of house cats were of significantly higher frequency than those of feral cats. Also, house cats produced calls of significantly shorter in duration than feral cats in agonistic test situations. These results support the conclusion that a lack of socialization may affect usage of types of vocalizations, and the vocal characteristics, so that the proper socialization of cat may be essential to be a suitable companion house cat. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Tailored Waveform of Dielectric Barrier Discharge to Control Composite Thin Film Morphology.

    PubMed

    Brunet, Paul; Rincón, Rocío; Matouk, Zineb; Chaker, Mohamed; Massines, Françoise

    2018-02-06

    Nanocomposite thin films of TiO 2 in a polymer-like matrix are grown in a filamentary argon (Ar) dielectric barrier discharge (DBD) from a suspension of TiO 2 nanoparticles in isopropanol (IPA). The sinusoidal voltage producing the plasma is designed to independently control the matrix growth rate and the transport of nanoparticle (NP) aggregates to the surface. The useful FSK (frequency shift keying) modulation mode is chosen to successively generate two sinusoidal voltages: a high frequency of 15 kHz and a low frequency ranging from 0.5 to 3 kHz. The coating surface coverage by the NPs and the thickness of the matrix are measured as a function of the FSK parameters. The duty cycle between these two signals is varied from 0 to 100%. It is observed that the matrix thickness is mainly controlled by the power of the discharge, which largely depends on the high-frequency value. The quantity of NPs deposited in the composite thin film is proportional to the duration of the low frequency applied. The FSK waveform has a double modulation effect, allowing us to obtain a uniform coating as the NPs are not affected by the high frequency and the matrix growth rate is limited when the low frequency is applied. When it is close to a frequency limit, the low frequency acts like a filter for the NP aggregates. The higher the frequency, the smaller the size of the aggregates transferred to the surface. By changing only the FSK modulation parameters, the thin film can be switched from superhydrophobic to superhydrophilic, and under suitable conditions, a nanocomposite thin film is obtained.

  11. Turbulent Mixing Layer Control using Ns-DBD Plasma Actuators

    NASA Astrophysics Data System (ADS)

    Singh, Ashish; Little, Jesse

    2016-11-01

    A low speed turbulent mixing layer (Reθo =1282, U1 /U2 = 0 . 28 and U2 = 11 . 8 m / s) is subject to nanosecond pulse driven dielectric barrier discharge (ns-DBD) plasma actuation. The forcing frequency corresponds to a Strouhal number (St) of 0.032 which is the most amplified frequency based on stability theory. Flow response is studied as a function of the pulse energy, the energy input time scale (carrier frequency) and the duration of actuation (duty cycle). It is found that successful actuation requires a combination of forcing parameters. An evaluation of the forcing efficacy is achieved by examining different flow quantities such as momentum thickness, vorticity and velocity fluctuations. In accordance with past work, a dependence is found between the initial shear layer thickness and the energy coupled to the flow. More complex relationships are also revealed such as a limitation on the maximum pulse energy which yields control. Also, the pulse energy and the carrier frequency (inverse of period between successive pulses) are interdependent whereby an optimum exists between them and extreme values of either parameter is inconsonant with the control desired. These observations establish a rich and complex process behind ns-DBD plasma actuation. Air Force Office of Scientific Research (FA9550-12-1-0044).

  12. [Dependence of anti-inflammatory effects of high peak-power pulsed electromagnetic radiation of extremely high frequency on exposure parameters].

    PubMed

    Gapeev, A B; Mikhaĭlik, E N; Rubanik, A V; Cheremis, N K

    2007-01-01

    A pronounced anti-inflammatory effect of high peak-power pulsed electromagnetic radiation of extremely high frequency was shown for the first time in a model of zymosan-induced footpad edema in mice. Exposure to radiation of specific parameters (35, 27 GHz, peak power 20 kW, pulse widths 400-600 ns, pulse repetition frequency 5-500 Hz) decreased the exudative edema and local hyperthermia by 20% compared to the control. The kinetics and the magnitude of the anti-inflammatory effect were comparable with those induced by sodium diclofenac at a dose of 3 mg/kg. It was found that the anti-inflammatory effect linearly increased with increasing pulse width at a fixed pulse repetition frequency and had threshold dependence on the average incident power density of the radiation at a fixed pulse width. When animals were whole-body exposed in the far-field zone of radiator, the optimal exposure duration was 20 min. Increasing the average incident power density upon local exposure of the inflamed paw accelerated both the development of the anti-inflammatory effect and the reactivation time. The results obtained will undoubtedly be of great importance in the hygienic standardization of pulsed electromagnetic radiation and in further studies of the mechanisms of its biological action.

  13. A Comparison between the WATCH Flare Data Statistical Properties and Predictions of the Statistical Flare Model

    NASA Astrophysics Data System (ADS)

    Crosby, N.; Georgoulis, M.; Vilmer, N.

    1999-10-01

    Solar burst observations in the deka-keV energy range originating from the WATCH experiment aboard the GRANAT spacecraft were used to perform frequency distributions built on measured X-ray flare parameters (Crosby et al., 1998). The results of the study show that: 1- the overall distribution functions are robust power laws extending over a number of decades. The typical parameters of events (total counts, peak count rates, duration) are all correlated to each other. 2- the overall distribution functions are the convolution of significantly different distribution functions built on parts of the whole data set filtered by the event duration. These "partial" frequency distributions are still power law distributions over several decades, with a slope systematically decreasing with increasing duration. 3- No correlation is found between the elapsed time interval between successive bursts arising from the same active region and the peak intensity of the flare. In this paper, we attempt a tentative comparison between the statistical properties of the self-organized critical (SOC) cellular automaton statistical flare models (see e.g. Lu and Hamilton (1991), Georgoulis and Vlahos (1996, 1998)) and the respective properties of the WATCH flare data. Despite the inherent weaknesses of the SOC models to simulate a number of physical processes in the active region, it is found that most of the observed statistical properties can be reproduced using the SOC models, including the various frequency distributions and scatter plots. We finally conclude that, even if SOC models must be refined to improve the physical links to MHD approaches, they nevertheless represent a good approach to describe the properties of rapid energy dissipation and magnetic field annihilation in complex and magnetized plasmas. Crosby N., Vilmer N., Lund N. and Sunyaev R., A&A; 334; 299-313; 1998 Crosby N., Lund N., Vilmer N. and Sunyaev R.; A&A Supplement Series; 130, 233, 1998 Georgoulis M. and Vlahos L., 1996, Astrophy. J. Letters, 469, L135 Georgoulis M. and Vlahos L., 1998, in preparation Lu E.T. and Hamilton R.J., 1991, Astroph. J., 380, L89

  14. Detectable signals of episodic risk effects on acute HIV transmission: Strategies for analyzing transmission systems using genetic data

    PubMed Central

    Alam, Shah Jamal; Zhang, Xinyu; Romero-Severson, Ethan Obie; Henry, Christopher; Zhong, Lin; Volz, Erik M.; Brenner, Bluma G.; Koopman, James S.

    2013-01-01

    Episodic high-risk sexual behavior is common and can have a profound effect on HIV transmission. In a model of HIV transmission among men who have sex with men (MSM), changing the frequency, duration and contact rates of high-risk episodes can take endemic prevalence from zero to 50% and more than double transmissions during acute HIV infection (AHI). Undirected test and treat could be inefficient in the presence of strong episodic risk effects. Partner services approaches that use a variety of control options will be likely to have better effects under these conditions, but the question remains: What data will reveal if a population is experiencing episodic risk effects? HIV sequence data from Montreal reveals genetic clusters whose size distribution stabilizes over time and reflects the size distribution of acute infection outbreaks (AIOs). Surveillance provides complementary behavioral data. In order to use both types of data efficiently, it is essential to examine aspects of models that affect both the episodic risk effects and the shape of transmission trees. As a demonstration, we use a deterministic compartmental model of episodic risk to explore the determinants of the fraction of transmissions during acute HIV infection (AHI) at the endemic equilibrium. We use a corresponding individual-based model to observe AIO size distributions and patterns of transmission within AIO. Episodic risk parameters determining whether AHI transmission trees had longer chains, more clustered transmissions from single individuals, or different mixes of these were explored. Encouragingly for parameter estimation, AIO size distributions reflected the frequency of transmissions from acute infection across divergent parameter sets. Our results show that episodic risk dynamics influence both the size and duration of acute infection outbreaks, thus providing a possible link between genetic cluster size distributions and episodic risk dynamics. PMID:23438430

  15. Effects of Reducing the Frequency and Duration Criteria for Binge Eating on Lifetime Prevalence of Bulimia Nervosa and Binge Eating Disorder: Implications for DSM-5

    PubMed Central

    Trace, Sara E.; Thornton, Laura M.; Root, Tammy L.; Mazzeo, Suzanne E.; Lichtenstein, Paul; Pedersen, Nancy L.; Bulik, Cynthia M.

    2011-01-01

    Objective We assessed the impact of reducing the binge eating frequency and duration thresholds on the diagnostic criteria for bulimia nervosa (BN) and binge eating disorder (BED). Method We estimated the lifetime population prevalence of BN and BED in 13,295 female twins from the Swedish Twin study of Adults: Genes and Environment employing a range of frequency and duration thresholds. External validation (risk to co-twin) was used to investigate empirical evidence for an optimal binge eating frequency threshold. Results The lifetime prevalence estimates of BN and BED increased linearly as the frequency criterion decreased. As the required duration increased, the prevalence of BED decreased slightly. Discontinuity in co-twin risk was observed in BN between at least four times per month and at least five times per month. This model could not be fit for BED. Discussion The proposed changes to the DSM-5 binge eating frequency and duration criteria would allow for better detection of binge eating pathology without resulting in a markedly higher lifetime prevalence of BN or BED. PMID:21882218

  16. Observation of the Mating Behavior of Honey Bee (Apis mellifera L.) Queens Using Radio-Frequency Identification (RFID): Factors Influencing the Duration and Frequency of Nuptial Flights

    PubMed Central

    Heidinger, Ina Monika Margret; Meixner, Marina Doris; Berg, Stefan; Büchler, Ralph

    2014-01-01

    We used radio-frequency identification (RFID) to record the duration and frequency of nuptial flights of honey bee queens (Apis mellifera carnica) at two mainland mating apiaries. We investigated the effect of a number of factors on flight duration and frequency: mating apiary, number of drone colonies, queen’s age and temperature. We found significant differences between the two locations concerning the number of flights on the first three days. We also observed an effect of the ambient temperature, with queens flying less often but longer at high temperatures compared to lower temperatures. Increasing the number of drone colonies from 33 to 80 colonies had no effect on the duration or on the frequency of nuptial flights. Since our results agree well with the results of previous studies, we suggest RFID as an appropriate tool to investigate the mating behavior of honey bee queens. PMID:26462822

  17. Integrative neural networks model for prediction of sediment rating curve parameters for ungauged basins

    NASA Astrophysics Data System (ADS)

    Atieh, M.; Mehltretter, S. L.; Gharabaghi, B.; Rudra, R.

    2015-12-01

    One of the most uncertain modeling tasks in hydrology is the prediction of ungauged stream sediment load and concentration statistics. This study presents integrated artificial neural networks (ANN) models for prediction of sediment rating curve parameters (rating curve coefficient α and rating curve exponent β) for ungauged basins. The ANN models integrate a comprehensive list of input parameters to improve the accuracy achieved; the input parameters used include: soil, land use, topographic, climatic, and hydrometric data sets. The ANN models were trained on the randomly selected 2/3 of the dataset of 94 gauged streams in Ontario, Canada and validated on the remaining 1/3. The developed models have high correlation coefficients of 0.92 and 0.86 for α and β, respectively. The ANN model for the rating coefficient α is directly proportional to rainfall erosivity factor, soil erodibility factor, and apportionment entropy disorder index, whereas it is inversely proportional to vegetation cover and mean annual snowfall. The ANN model for the rating exponent β is directly proportional to mean annual precipitation, the apportionment entropy disorder index, main channel slope, standard deviation of daily discharge, and inversely proportional to the fraction of basin area covered by wetlands and swamps. Sediment rating curves are essential tools for the calculation of sediment load, concentration-duration curve (CDC), and concentration-duration-frequency (CDF) analysis for more accurate assessment of water quality for ungauged basins.

  18. Sigmund Freud's practice: visits and consultation, psychoanalyses, remuneration.

    PubMed

    Tögel, Christfried

    2009-10-01

    This paper provides an overview of the quantitative side of the systematic records kept by Freud on his practice. He left precise records of the duration, frequency, and fees of psychoanalytic treatments. These statistics are compared with the treatment duration and frequency customary in present-day psychoanalytic practice in German-speaking countries. The results suggest that, regarding frequency and duration and their relationship, there is little difference between Freud's psychoanalytic practice and that of the present day.

  19. A fast algorithm for automatic detection of ionospheric disturbances: DROT

    NASA Astrophysics Data System (ADS)

    Efendi, Emre; Arikan, Feza

    2017-06-01

    Solar, geomagnetic, gravitational and seismic activities cause disturbances in the ionospheric region of upper atmosphere that may disrupt or lower the quality of space based communication, navigation and positioning system signals. These disturbances can be categorized with respect to their amplitude, duration and frequency. Typically in the literature, ionospheric disturbances are investigated with gradient based methods on Total Electron Content (TEC) data estimated from ground based dual frequency Global Positioning System (GPS) receivers. In this study, a fast algorithm is developed for the automatic detection of the variability in Slant TEC (STEC) data. STEC is defined as the total number of electrons on the ray path between the ground based receiver and GPS satellite in the orbital height of 20,000 km. The developed method, namely, Differential Rate of TEC (DROT), is based on Rate of Tec (ROT) method. ROT is widely used in the literature and it is usually applied to Vertical TEC (VTEC) that corresponds to the projection of STEC to the vertical direction along the ray path at the Ionospheric Pierce Point (IPP) using a mapping function. The developed DROT method can be defined as the normalized metric norm between the ROT and its baseband trend structure. In this study, the performance of DROT is determined using synthetic data with variable bounds on the parameter set of amplitude, frequency and duration of disturbance. It is observed that DROT method can detect disturbances in three categories. For DROT values less than 50%, there is no significant disturbance in STEC data. For DROT values between 50% and 70%, a medium scale disturbance can be observed. For DROT values over 70%, severe disturbances such as Large Scale Traveling Ionospheric Disturbances (LSTIDs) can be observed. DROT method is highly sensitive to the amplitude of the wave-like oscillations. For a disturbance amplitude as low as 1.01 TECU, the disturbances that have durations longer than or equal to 20 min and frequencies higher than 1.095 mHz; or frequencies higher than 0.511 mHz and durations longer than 55 min can be detected automatically with DROT values of 50%. When DROT method is applied to midlatitude STEC values for disturbed days, it is observed that DROT method can detect the disturbances in near-real time, even if the GPS data from the station is uploaded with 15 min intervals.

  20. Lexical frequency and acoustic reduction in spoken Dutch

    NASA Astrophysics Data System (ADS)

    Pluymaekers, Mark; Ernestus, Mirjam; Baayen, R. Harald

    2005-10-01

    This study investigates the effects of lexical frequency on the durational reduction of morphologically complex words in spoken Dutch. The hypothesis that high-frequency words are more reduced than low-frequency words was tested by comparing the durations of affixes occurring in different carrier words. Four Dutch affixes were investigated, each occurring in a large number of words with different frequencies. The materials came from a large database of face-to-face conversations. For each word containing a target affix, one token was randomly selected for acoustic analysis. Measurements were made of the duration of the affix as a whole and the durations of the individual segments in the affix. For three of the four affixes, a higher frequency of the carrier word led to shorter realizations of the affix as a whole, individual segments in the affix, or both. Other relevant factors were the sex and age of the speaker, segmental context, and speech rate. To accommodate for these findings, models of speech production should allow word frequency to affect the acoustic realizations of lower-level units, such as individual speech sounds occurring in affixes.

  1. Key Physiological Parameters Dictate Triggering of Activity-Dependent Bulk Endocytosis in Hippocampal Synapses

    PubMed Central

    Wenzel, Eva M.; Morton, Andrew; Ebert, Katrin; Welzel, Oliver; Kornhuber, Johannes; Cousin, Michael A.; Groemer, Teja W.

    2012-01-01

    To maintain neurotransmission in central neurons, several mechanisms are employed to retrieve synaptically exocytosed membrane. The two major modes of synaptic vesicle (SV) retrieval are clathrin-mediated endocytosis and activity-dependent bulk endocytosis (ADBE). ADBE is the dominant SV retrieval mode during intense stimulation, however the precise physiological conditions that trigger this mode are not resolved. To determine these parameters we manipulated rat hippocampal neurons using a wide spectrum of stimuli by varying both the pattern and duration of stimulation. Using live-cell fluorescence imaging and electron microscopy approaches, we established that stimulation frequency, rather than the stimulation load, was critical in the triggering of ADBE. Thus two hundred action potentials, when delivered at high frequency, were sufficient to induce near maximal bulk formation. Furthermore we observed a strong correlation between SV pool size and ability to perform ADBE. We also identified that inhibitory nerve terminals were more likely to utilize ADBE and had a larger SV recycling pool. Thus ADBE in hippocampal synaptic terminals is tightly coupled to stimulation frequency and is more likely to occur in terminals with large SV pools. These results implicate ADBE as a key modulator of both hippocampal neurotransmission and plasticity. PMID:22675521

  2. Kinetic study of terahertz generation based on the interaction of two-color ultra-short laser pulses with molecular hydrogen gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soltani Gishini, M. S.; Ganjovi, A., E-mail: Ganjovi@kgut.ac.ir; Saeed, M.

    In this work, using a two dimensional particle in cell-Monte Carlo collision simulation scheme, interaction of two-color ultra-short laser pulses with the molecular hydrogen gas (H{sub 2}) is examined. The operational laser parameters, i.e., its pulse shape, duration, and waist, are changed and, their effects on the density and kinetic energy of generated electrons, THz electric field, intensity, and spectrum are studied. It is seen that the best pulse shape generating the THz signal radiation with the highest intensity is a trapezoidal pulse, and the intensity of generated THz radiation is increased at the higher pulse durations and waists. Formore » all the operational laser parameters, the maximum value of emitted THz signal frequency always remains lower than 5 THz. The intensity of applied laser pulses is taken about 10{sup 14} w/cm{sup 2}, and it is observed that while a small portion of the gaseous media gets ionized, the radiated THz signal is significant.« less

  3. Thoracic auscultation in captive bottlenose dolphins (Tursiops truncatus), California sea lions (Zalophus californianus), and South African fur seals (Arctocephalus pusillus) with an electronic stethoscope.

    PubMed

    Scharpegge, Julia; Hartmann, Manuel García; Eulenberger, Klaus

    2012-06-01

    Thoracic auscultation is an important diagnostic method used in cases of suspected pulmonary disease in many species, as respiratory sounds contain significant information on the physiology and pathology of the lungs and upper airways. Respiratory diseases are frequent in marine mammals and are often listed as one of their main causes of death. The aim of this study was to investigate and report baseline parameters for the electronic-mediated thoracic auscultation of one cetacean species and two pinniped species in captivity. Respiratory sounds from 20 captive bottlenose dolphins (Tursiops truncatus), 6 California sea lions (Zalophus californianus), and 5 South African fur seals (Arctocephalus pusillus) were recorded with an electronic stethoscope. The sounds were analyzed for duration of the respiratory cycle, adventitious sounds, and peak frequencies of recorded sounds during expiration and inspiration as well as for sound intensity as reflected by waveform amplitude during the respiratory cycle. In respiratory cycles of the bottlenose dolphins' expiring "on command," the duration of the expiration was significantly shorter than the duration of the inspiration. In the examined pinnipeds of this study, there was no clear pattern concerning the duration of one breathing phase: Adventitious sounds were detected most often in bottlenose dolphins that were expiring on command and could be compared with "forced expiratory wheezes" in humans. This is the first report of forced expiratory wheezes in bottlenose dolphins; they can easily be misinterpreted as pathologic respiratory sounds. The peak frequencies of the respiratory sounds reached over 2,000 Hz in bottlenose dolphins and over 1,000 Hz in California sea lions and South African fur seals, but the variation of the frequency spectra was very high in all animals. To the authors' knowledge, this is the first systematic analysis of respiratory sounds of bottlenose dolphins and two species of pinnipeds.

  4. Factor Analysis of Low-Frequency Repetitive Transcranial Magnetic Stimulation to the Temporoparietal Junction for Tinnitus

    PubMed Central

    Li, Bei; Wang, Meiye; Li, Ming; Yin, Shankai

    2016-01-01

    Objectives. We investigated factors that contribute to suppression of tinnitus after repetitive transcranial magnetic stimulation (rTMS). Methods. A total of 289 patients with tinnitus underwent active 1 Hz rTMS in the left temporoparietal region. A visual analog scale (VAS) was used to assess tinnitus loudness. All participants were interviewed regarding age, gender, tinnitus duration, laterality and pitch, audiometric parameters, sleep, and so forth. The resting motor thresholds (RMTs) were measured in all patients and 30 age- and gender-matched volunteers. Results. With respect to different factors that contribute to tinnitus suppression, we found improvement in the following domains: shorter duration, normal hearing (OR: 3.25, 95%CI: 2.01–5.27, p = 0.001), and without sleep disturbance (OR: 2.51, 95%CI: 1.56–4.1, p = 0.005) adjusted for age and gender. The patients with tinnitus lasting less than 1 year were more likely to show suppression of tinnitus (OR: 2.77, 95%CI: 1.48–5.19, p = 0.002) compared to those with tinnitus lasting more than 5 years. Tinnitus patients had significantly lower RMTs compared with healthy volunteers. Conclusion. Active low-frequency rTMS results in a significant reduction in the loudness of tinnitus. Significant tinnitus suppression was shown in subjects with shorter tinnitus duration, with normal hearing, and without sleep disturbance. PMID:27847647

  5. Analysis of streambed temperatures in ephemeral channels to determine streamflow frequency and duration

    USGS Publications Warehouse

    Constantz, James E.; Stonestrom, David A.; Stewart, Amy E.; Niswonger, Richard G.; Smith, Tyson R.

    2001-01-01

    Spatial and temporal patterns in streamflow are rarely monitored for ephemeral streams. Flashy, erosive streamflows common in ephemeral channels create a series of operational and maintenance problems, which makes it impractical to deploy a series of gaging stations along ephemeral channels. Streambed temperature is a robust and inexpensive parameter to monitor remotely, leading to the possibility of analyzing temperature patterns to estimate streamflow frequency and duration along ephemeral channels. A simulation model was utilized to examine various atmospheric and hydrological upper boundary conditions compared with a series of hypothetical temperature‐monitoring depths within the streambed. Simulation results indicate that streamflow events were distinguished from changing atmospheric conditions with greater certainty using temperatures at shallow depths (e.g., 10–20 cm) as opposed to the streambed surface. Three ephemeral streams in the American Southwest were instrumented to monitor streambed temperature for determining the accuracy of using this approach to ascertain the long‐term temporal and spatial extent of streamflow along each stream channel. Streambed temperature data were collected at the surface or at shallow depth along each stream channel, using thermistors encased in waterproof, single‐channel data loggers tethered to anchors in the channel. On the basis of comparisons with site information, such as direct field observations and upstream flow records, diurnal temperature variations successfully detected the presence and duration of streamflow for all sites.

  6. Effect of level, duration, and inter-pulse interval of 1-2 kHz sonar signal exposures on harbor porpoise hearing.

    PubMed

    Kastelein, Ronald A; Hoek, Lean; Gransier, Robin; Rambags, Martijn; Claeys, Naomi

    2014-07-01

    Safety criteria for underwater low-frequency active sonar sounds produced during naval exercises are needed to protect harbor porpoise hearing. As a first step toward defining criteria, a porpoise was exposed to sequences consisting of series of 1-s, 1-2 kHz sonar down-sweeps without harmonics (as fatiguing noise) at various combinations of average received sound pressure levels (SPLs; 144-179 dB re 1 μPa), exposure durations (1.9-240 min), and duty cycles (5%-100%). Hearing thresholds were determined for a narrow-band frequency-swept sine wave centered at 1.5 kHz before exposure to the fatiguing noise, and at 1-4, 4-8, 8-12, 48, 96, 144, and 1400 min after exposure, to quantify temporary threshold shifts (TTSs) and recovery of hearing. Results show that the inter-pulse interval of the fatiguing noise is an important parameter in determining the magnitude of noise-induced TTS. For the reported range of exposure combinations (duration and SPL), the energy of the exposure (i.e., cumulative sound exposure level; SELcum) can be used to predict the induced TTS, if the inter-pulse interval is known. Exposures with equal SELcum but with different inter-pulse intervals do not result in the same induced TTS.

  7. Atlas of depth-duration frequency of precipitation annual maxima for Texas

    USGS Publications Warehouse

    Asquith, William H.; Roussel, Meghan C.

    2004-01-01

    The objective of this Texas Department of Transportation (TxDOT) and U.S. Geological Survey (USGS) cooperatively funded project was to develop a simple-to-use atlas of precipitation depths in Texas for selected storm durations and frequencies on the basis of the research results and unpublished digital archives of Asquith (1998). The selected storm durations are 15 and 30 minutes; 1, 2, 3, 6, and 12 hours; and 1, 2, 3, 5, and 7 days. The selected storm frequencies or annual recurrence intervals are 2, 5, 10, 25, 50, 100, 250, and 500 years. Depth-duration frequency (DDF) of annual precipitation maxima is important for cost-effective, risk-mitigated hydrologic design. DDF values are in common and wide-spread use by public and private entities throughout Texas.

  8. The Effect of Frequency Altered Feedback on Stuttering Duration and Type

    ERIC Educational Resources Information Center

    Stuart, Andrew; Frazier, Carmen L.; Kalinowski, Joseph; Vos, Paul W.

    2008-01-01

    Purpose: The effect of frequency altered feedback (FAF) on stuttering type (i.e., prolongation, repetition, or silent block) and stuttering duration (i.e., average duration of stuttering event and total stuttering time) was examined. Method: Retrospective analyses of previously collected data from 12 adult persons who stutter who participated in…

  9. The Emergence of Frequency Effects in Eye Movements

    ERIC Educational Resources Information Center

    Vanyukov, Polina M.; Warren, Tessa; Wheeler, Mark E.; Reichle, Erik D.

    2012-01-01

    A visual search experiment employed strings of Landolt "C"s to examine how the gap size of and frequency of exposure to distractor strings affected eye movements. Increases in gap size were associated with shorter first-fixation durations, gaze durations, and total times, as well as fewer fixations. Importantly, both the number and duration of…

  10. A single scaling parameter as a first approximation to describe the rainfall pattern of a place: application on Catalonia

    NASA Astrophysics Data System (ADS)

    Casas-Castillo, M. Carmen; Llabrés-Brustenga, Alba; Rius, Anna; Rodríguez-Solà, Raúl; Navarro, Xavier

    2018-02-01

    As well as in other natural processes, it has been frequently observed that the phenomenon arising from the rainfall generation process presents fractal self-similarity of statistical type, and thus, rainfall series generally show scaling properties. Based on this fact, there is a methodology, simple scaling, which is used quite broadly to find or reproduce the intensity-duration-frequency curves of a place. In the present work, the relationship of the simple scaling parameter with the characteristic rainfall pattern of the area of study has been investigated. The calculation of this scaling parameter has been performed from 147 daily rainfall selected series covering the temporal period between 1883 and 2016 over the Catalonian territory (Spain) and its nearby surroundings, and a discussion about the relationship between the scaling parameter spatial distribution and rainfall pattern, as well as about trends of this scaling parameter over the past decades possibly due to climate change, has been presented.

  11. Optimization of hybrid laser - TIG welding of 316LN steel using response surface methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Ragavendran, M.; Chandrasekhar, N.; Ravikumar, R.; Saxena, Rajesh; Vasudevan, M.; Bhaduri, A. K.

    2017-07-01

    In the present study, the hybrid laser - TIG welding parameters for welding of 316LN austenitic stainless steel have been investigated by combining a pulsed laser beam with a TIG welding heat source at the weld pool. Laser power, pulse frequency, pulse duration, TIG current were presumed as the welding process parameters whereas weld bead width, weld cross-sectional area and depth of penetration (DOP) were considered as the process responses. Central composite design was used to complete the design matrix and welding experiments were conducted based on the design matrix. Weld bead measurements were then carried out to generate the dataset. Multiple regression models correlating the process parameters with the responses have been developed. The accuracy of the models were found to be good. Then, the desirability approach optimization technique was employed for determining the optimum process parameters to obtain the desired weld bead profile. Validation experiments were then carried out from the determined optimum process parameters. There was good agreement between the predicted and measured values.

  12. Methods for estimating magnitude and frequency of 1-, 3-, 7-, 15-, and 30-day flood-duration flows in Arizona

    USGS Publications Warehouse

    Kennedy, Jeffrey R.; Paretti, Nicholas V.; Veilleux, Andrea G.

    2014-01-01

    Regression equations, which allow predictions of n-day flood-duration flows for selected annual exceedance probabilities at ungaged sites, were developed using generalized least-squares regression and flood-duration flow frequency estimates at 56 streamgaging stations within a single, relatively uniform physiographic region in the central part of Arizona, between the Colorado Plateau and Basin and Range Province, called the Transition Zone. Drainage area explained most of the variation in the n-day flood-duration annual exceedance probabilities, but mean annual precipitation and mean elevation were also significant variables in the regression models. Standard error of prediction for the regression equations varies from 28 to 53 percent and generally decreases with increasing n-day duration. Outside the Transition Zone there are insufficient streamgaging stations to develop regression equations, but flood-duration flow frequency estimates are presented at select streamgaging stations.

  13. Prospective study of bacteraemia in acute haemorrhagic diarrhoea syndrome in dogs.

    PubMed

    Unterer, S; Lechner, E; Mueller, R S; Wolf, G; Straubinger, R K; Schulz, B S; Hartmann, K

    2015-03-21

    In dogs with idiopathic acute haemorrhagic diarrhoea syndrome (AHDS), a serious loss of intestinal mucosal barrier integrity occurs. However, the incidence of bacterial translocation in dogs with idiopathic AHDS is not known. Thus, the objectives of this prospective study were to identify the incidence of bacteraemia, to evaluate the frequency of septic events and the influence of bacteraemia on various clinical and laboratory parameters, duration of hospitalisation and survival of dogs with idiopathic AHDS. The study included 87 dogs with idiopathic AHDS. Twenty-one healthy dogs served as control group. To evaluate clinical significance of bacterial translocation, blood culture results were compared between patients and controls. Clinical and laboratory parameters were compared between patients with positive and negative blood cultures. There was no significant difference in either incidence of bacteraemia between patients with idiopathic AHDS (11 per cent) and controls (14 per cent) or in severity of clinical signs, laboratory parameters, duration of hospitalisation or mortality between blood culture-positive and culture-negative dogs with idiopathic AHDS. The results of this study suggest that the incidence of bacteraemia in dogs with idiopathic AHDS is low and not different from that of healthy control dogs. Bacteraemia does not influence the clinical course or survival and thus antibiotic treatment is not indicated to prevent sepsis. British Veterinary Association.

  14. The multi-parameter borehole system and high resolution seismic studies in the western part of the main Marmara Fault in the frame of MARSITE Project.

    NASA Astrophysics Data System (ADS)

    Ozel, Oguz; Guralp, Cansun; Tunc, Suleyman; Yalcinkaya, Esref

    2016-04-01

    The main objective of this study is to install a multi-parameter borehole system and surface array as close to the main Marmara Fault (MMF) in the western Marmara Sea as possible, and measure continuously the evolution of the state of the fault zone surrounding the MMF and to detect any anomaly or change, which may occur before earthquakes by making use of the data from the arrays already running in the eastern part of the Marmara Sea. The multi-parameter borehole system is composed of very wide dynamic range and stable borehole (VBB) broad band seismic sensor, and incorporate strain meter, tilt meter, and temperature and local hydrostatic pressure measuring devices. The borehole seismic station uses the latest update technologies and design ideas to record "Earth tides" signals to the smallest magnitude -3 events. Additionally, a surface microearthquake observation array, consisting of 8-10 seismometers around the borehole is established to obtain continuous high resolution locations of micro-seismicity and to better understand the existing seismically active structures and their roles in local tectonic settings.Bringing face to face the seismograms of microearthquakes recorded by borehole and surface instruments portrays quite different contents. The shorter recording duration and nearly flat frequency spectrum up to the Nyquist frequencies of borehole records are faced with longer recording duration and rapid decay of spectral amplitudes at higher frequencies of a surface seismogram. The main causative of the observed differences are near surface geology effects that mask most of the source related information the seismograms include, and that give rise to scattering, generating longer duration seismograms. In view of these circumstances, studies on microearthquakes employing surface seismograms may bring on misleading results. Particularly, the works on earthquake physics and nucleation process of earthquakes requires elaborate analysis of tiny events. It is obvious from the studies on the nucleation process of the 1999 earthquake that tens of minutes before the major rupture initiate noteworthy microearthquake activity happened. The starting point of the 1999 rupture was a site of swarm activity noticed a few decades prior the main shock. Nowadays, analogous case is probable in western Marmara Sea region, prone to a major event in near future where the seismic activity is prevailing along the impending rupture zone. Deploying a borehole system eastern end of the Ganos fault zone may yield invaluable data to closely inspect and monitor the last stages of the preparation stage of major rupture.

  15. Young children's hand contact activities: an observational study via videotaping in primarily outdoor residential settings.

    PubMed

    Auyeung, Willa; Canales, Robert A; Beamer, Paloma; Ferguson, Alesia C; Leckie, James O

    2006-09-01

    Microlevel activity time series (MLATS) data were gathered on hand contact activities of 38 children (1-6 years old) by videotaping in primarily outdoor residential environments. The videotape recordings were then translated into text files using a specialized software called VirtualTimingDevicetrade mark. Contact frequency (contacts/h), duration per contact (s/contact), and hourly contact duration (min/h) were summarized for outdoor hand contacts with 15 distinct object/surface categories ("Animal", "Body", "Clothes/Towels", "Fabric", "Floor", "Food", "Footwear", "Metal", "Non-dietary Water", "Paper/Wrapper", "Plastic", "Rock/Brick", "Toys", "Vegetation/Grass", and "Wood") and two aggregate object/surface categories ("Non-dietary objects/surfaces" and "Total objects/surfaces"). For outdoor both hand contacts with "Total objects/surfaces", contact frequencies ranged from 229.9 to 1517.7 contacts/h, median durations/contact ranged from < 1 to 5 s, and hourly contact durations ranged from 42.6 to 102.2 m/h. The data were analyzed for significant differences in hand contact activities as a function of (1) age, (2) location, (3) gender, and (4) hand. Significant differences (P < or = 0.05) were found for all four factors analyzed. Hourly contact durations with "Non-dietary objects/surfaces" and "Total objects/surfaces" increased with age (P = 0.01, rs = 0.42 and P = 0.005, rs = 0.46, respectively), while contact frequencies and hourly contact durations with "Wood" decreased with age (P = 0.02, rs = -0.38 and P = 0.05, rs = -0.32, respectively). Location was found to affect contact frequencies and hourly contact durations with certain objects/surfaces. For example, contact frequencies and hourly contact durations with "Fabric" were higher indoors (P = 0.02 for both), while contact frequencies and hourly contact durations with "Vegetation/Grass" were higher outdoors (P = 0.02 and P = 0.04, respectively). Girls had longer hourly contact durations with "Footwear" (P = 0.02), "Non-dietary objects/surfaces" (P = 0.03), and "Total objects/surfaces" (P = 0.01) than boys. The right hand had longer hourly contact durations with objects that are often manipulated with the hand (e.g., "Toys" (P = 0.0002)), while the left hand had longer hourly contact durations with passively touched objects/surfaces (e.g., "Clothes/Towels" (P = 0.003) and "Floor" (P = 0.04)).

  16. Levothyroxine treatment generates an abnormal uterine contractility patterns in an in vitro animal model.

    PubMed

    Corriveau, Stéphanie; Blouin, Simon; Raiche, Évelyne; Nolin, Marc-Antoine; Rousseau, Éric; Pasquier, Jean-Charles

    2015-12-01

    Abnormal uterine contraction patterns were recently demonstrated in uterine strips from pregnant women treated with Levothyroxine (T4). These abnormalities were correlated with an increased risk of C-section delivery and associated surgical complications. To date, no study has investigated whether uterine contractility is modified by hypothyroidism or T4 treatment. Herein, we analyze the physiological role of T4 on uterine contractions. Female non-pregnant Sprague-Dawley rats ( N  = 22) were used and divided into four groups: 1) control, 2) hypothyroidism, 3) hypothyroidism treated with low T4 doses (20 μg/kg/day) and 4) with high T4 doses (100 μg/kg/day). Hypothyroidism was induced by an iodine-deficient diet. Isometric tension measurements were performed in vitro on myometrium tissues in isolated organ baths. Contractile activity parameters were quantified (amplitude, duration, frequency and area under the curve) using pharmacological tools to assess their effect. Screening of thyroid function confirmed a hypothyroid state for all rats under iodine-free diet to which T4 was subsequently administered to counterbalance hypothyroidism. Results demonstrate that hypothyroidism significantly decreased contractile duration (-17%) and increased contractile frequency (+26%), while high doses of T4 increased duration (+200%) and decreased frequency (-51%). These results thus mimic the pattern of abnormal contractions previously observed in uterine tissue from T4-treated hypothyroid pregnant women. Our data suggest that changes in myometrial reactivity are induced by T4 treatment. Thus, in conjunction with our previous observations on human myometrial strips, management of hypothyroidism should be improved to reduce the rate of C-sections in this group of patients.

  17. Future projection of design storms using a GCM-informed weather generator

    NASA Astrophysics Data System (ADS)

    KIm, T. W.; Wi, S.; Valdés-Pineda, R.; Valdés, J. B.

    2017-12-01

    The rainfall Intensity-Duration-Frequency (IDF) curves are one of the most common tools used to provide planners with a description of the frequency of extreme rainfall events of various intensities and durations. Therefore deriving appropriate IDF estimates is important to avoid malfunctions of water structures that cause huge damage. Evaluating IDF estimates in the context of climate change has become more important because projections from climate models suggest that the frequency of intense rainfall events will increase in the future due to the increase in greenhouse gas emissions. In this study, the Bartlett-Lewis (BL) stochastic rainfall model is employed to generate annual maximum series of various sub-daily durations for test basins of the Model Parameter Estimation Experiment (MOPEX) project, and to derive the IDF curves in the context of climate changes projected by the North American Regional Climate Change (NARCCAP) models. From our results, it has been found that the observed annual rainfall maximum series is reasonably represented by the synthetic annual maximum series generated by the BL model. The observed data is perturbed by change factors to incorporate the NARCCAP climate change scenarios into the IDF estimates. The future IDF curves show a significant difference from the historical IDF curves calculated for the period 1968-2000. Overall, the projected IDF curves show an increasing trend over time. The impacts of changes in extreme rainfall on the hydrologic response of the MOPEX basins are also explored. Acknowledgement: This research was supported by a grant [MPSS-NH-2015-79] through the Disaster and Safety Management Institute funded by Ministry of Public Safety and Security of Korean government.

  18. Technical adequacy of growth estimates from a computer adaptive test: Implications for progress monitoring.

    PubMed

    Van Norman, Ethan R; Nelson, Peter M; Parker, David C

    2017-09-01

    Computer adaptive tests (CATs) hold promise to monitor student progress within multitiered systems of support. However, the relationship between how long and how often data are collected and the technical adequacy of growth estimates from CATs has not been explored. Given CAT administration times, it is important to identify optimal data collection schedules to minimize missed instructional time. We used simulation methodology to investigate how the duration and frequency of data collection influenced the reliability, validity, and precision of growth estimates from a math CAT. A progress monitoring dataset of 746 Grade 4, 664 Grade 5, and 400 Grade 6 students from 40 schools in the upper Midwest was used to generate model parameters. Across grades, 53% of students were female and 53% were White. Grade level was not as influential as the duration and frequency of data collection on the technical adequacy of growth estimates. Low-stakes decisions were possible after 14-18 weeks when data were collected weekly (420-540 min of assessment), 20-24 weeks when collected every other week (300-360 min of assessment), and 20-28 weeks (150-210 min of assessment) when data were collected once a month, depending on student grade level. The validity and precision of growth estimates improved when the duration and frequency of progress monitoring increased. Given the amount of time required to obtain technically adequate growth estimates in the present study, results highlight the importance of weighing the potential costs of missed instructional time relative to other types of assessments, such as curriculum-based measures. Implications for practice, research, as well as future directions are also discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. Regional analysis of annual precipitation maxima in Montana

    USGS Publications Warehouse

    Parrett, Charles

    1997-01-01

    Dimensionless precipitation-frequency curves for estimating precipitation depths having large recurrence intervals were developed for 2-, 6-, and 24-hour storm durations for three homogeneous regions in Montana. Within each homogeneous region, at-site annual precipitation maxima were made dimensionless by dividing by the at-site mean and grouped so that a single frequency curve would be applicable for each duration. L-moment statistics were used to help define the homogeneous regions and to develop the dimensionless precipitation- frequency curves. Data from 459 precipitation stations were used after application of statistical tests to ensure that the data were not serially correlated and were stationary over the general period of data collection (1900-92). The data were found to have a small, but significant, degree of interstation correlation. The GEV distribution was used to construct dimensionless frequency curves of annual precipitation maxima for each duration within each region. Each dimensionless frequency curve was considered to be reliable for recurrence intervals up to the effective record length. Because of significant, though small, interstation correlation in all regions for all durations, and because the selected regions exhibited some heterogeneity, the effective record length was considered to be less than the total number of station-years of data. The effective record length for each duration in each region was estimated using a graphical method and found to range from 500 years for 6-hour duration data in Region 2 to 5,100 years for 24-hour duration data in Region 3.

  20. Crack classification in concrete beams using AE parameters

    NASA Astrophysics Data System (ADS)

    Bahari, N. A. A. S.; Shahidan, S.; Abdullah, S. R.; Ali, N.; Zuki, S. S. Mohd; Ibrahim, M. H. W.; Rahim, M. A.

    2017-11-01

    The acoustic emission (AE) technique is an effective tool for the evaluation of crack growth. The aim of this study is to evaluate crack classification in reinforced concrete beams using statistical analysis. AE has been applied for the early monitoring of reinforced concrete structures using AE parameters such as average frequency, rise time, amplitude counts and duration. This experimental study focuses on the utilisation of this method in evaluating reinforced concrete beams. Beam specimens measuring 150 mm × 250 mm × 1200 mm were tested using a three-point load flexural test using Universal Testing Machines (UTM) together with an AE monitoring system. The results indicated that RA value can be used to determine the relationship between tensile crack and shear movement in reinforced concrete beams.

  1. Accelerated longitudinal designs: An overview of modelling, power, costs and handling missing data.

    PubMed

    Galbraith, Sally; Bowden, Jack; Mander, Adrian

    2017-02-01

    Longitudinal studies are often used to investigate age-related developmental change. Whereas a single cohort design takes a group of individuals at the same initial age and follows them over time, an accelerated longitudinal design takes multiple single cohorts, each one starting at a different age. The main advantage of an accelerated longitudinal design is its ability to span the age range of interest in a shorter period of time than would be possible with a single cohort longitudinal design. This paper considers design issues for accelerated longitudinal studies. A linear mixed effect model is considered to describe the responses over age with random effects for intercept and slope parameters. Random and fixed cohort effects are used to cope with the potential bias accelerated longitudinal designs have due to multiple cohorts. The impact of other factors such as costs and the impact of dropouts on the power of testing or the precision of estimating parameters are examined. As duration-related costs increase relative to recruitment costs the best designs shift towards shorter duration and eventually cross-sectional design being best. For designs with the same duration but differing interval between measurements, we found there was a cutoff point for measurement costs relative to recruitment costs relating to frequency of measurements. Under our model of 30% dropout there was a maximum power loss of 7%.

  2. Effects of relationship duration, cohabitation, and marriage on the frequency of intercourse in couples: Findings from German panel data.

    PubMed

    Schröder, Jette; Schmiedeberg, Claudia

    2015-07-01

    Research into the changes in the frequency of sexual intercourse is (with few exceptions) limited to cross-sectional analyses of marital duration. We investigate the frequency of intercourse while taking into account relationship duration as well as the duration of cohabitation and marriage, effects of parenthood, and relationship quality. For the analysis we apply fixed effects regression models using data from the German Family Panel (pairfam), a nationwide randomly sampled German panel survey. Our findings imply that the drop in sex frequency occurs early in the relationship, whereas neither cohabitation nor marriage affects the frequency of intercourse to a significant extent. Sex frequency is reduced during pregnancy and as long as the couple has small children, but becomes revived later on. Relationship quality is found to play a role as well. These results are contrary to the honeymoon effect found in earlier research, but indicate that in times of postponed marriage an analogous effect may be at work in the initial period of the relationship. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Direct lexical control of eye movements in reading: Evidence from a survival analysis of fixation durations

    PubMed Central

    Reingold, Eyal M.; Reichle, Erik D.; Glaholt, Mackenzie G.; Sheridan, Heather

    2013-01-01

    Participants’ eye movements were monitored in an experiment that manipulated the frequency of target words (high vs. low) as well as their availability for parafoveal processing during fixations on the pre-target word (valid vs. invalid preview). The influence of the word-frequency by preview validity manipulation on the distributions of first fixation duration was examined by using ex-Gaussian fitting as well as a novel survival analysis technique which provided precise estimates of the timing of the first discernible influence of word frequency on first fixation duration. Using this technique, we found a significant influence of word frequency on fixation duration in normal reading (valid preview) as early as 145 ms from the start of fixation. We also demonstrated an equally rapid non-lexical influence on first fixation duration as a function of initial landing position (location) on target words. The time-course of frequency effects, but not location effects was strongly influenced by preview validity, demonstrating the crucial role of parafoveal processing in enabling direct lexical control of reading fixation times. Implications for models of eye-movement control are discussed. PMID:22542804

  4. Sound characteristics of Terapon jorbua as a response to temperature changes

    NASA Astrophysics Data System (ADS)

    Amron; Jaya, I.; Hestirianoto, T.; Juterzenka, K. v.

    2017-10-01

    The change of water temperature has potential impact on the behavior of aquatic animal including fish which generated by their sound productivity and characteristics. This research aimed to study the response of sound productivity and characteristics of Terapon jorbua to temperature change. As a response to temperature increase, T. jorbua to have decreased the number of sound productivity. Two characteristic parameters of fish sound, i.e. intensity and frequency as were quadratic increased during the water temperature rises. In contrast, pulse duration was quadratic decreased.

  5. SITE AMPLIFICATION OF EARTHQUAKE GROUND MOTION.

    USGS Publications Warehouse

    Hays, Walter W.

    1986-01-01

    When analyzing the patterns of damage in an earthquake, physical parameters of the total earthquake-site-structure system are correlated with the damage. Soil-structure interaction, the cause of damage in many earthquakes, involves the frequency-dependent response of both the soil-rock column and the structure. The response of the soil-rock column (called site amplification) is controversial because soil has strain-dependent properties that affect the way the soil column filters the input body and surface seismic waves, modifying the amplitude and phase spectra and the duration of the surface ground motion.

  6. Tooth pulp stimulation as an unconditioned stimulus in defensive instrumental conditioning.

    PubMed

    Jastreboff, P J; Keller, O; Zieliński, K

    1977-01-01

    In an experiment performed on five cats, stable escape and avoidance reflexes in a bar-pressing situation were established using tooth pulp electric stimulation as the unconditioned stimulus. The influence of changes in parameters of the unconditioned stimulus (current intensity, single pulse and train durations, frequency of pulses and rate of train presentations) on unconditioned and instrumental responses was analysed in three additional subjects. Among other relationships the dependence of the threshold of bar press responses on the amount of charge in a single pulse was determined.

  7. Carrier-envelope-offset phase control of ultrafast optical rectification in resonantly excited semiconductors.

    PubMed

    Van Vlack, C; Hughes, S

    2007-04-20

    Ultrashort pulse light-matter interactions in a semiconductor are investigated within the regime of resonant optical rectification. Using pulse envelope areas of around 1.5-3.5 pi, a single-shot dependence on carrier-envelope-offset phase (CEP) is demonstrated for 5 fs pulse durations. A characteristic phase map is predicted for several different frequency regimes using parameters for thin-film GaAs. We subsequently suggest a possible technique to extract the CEP, in both sign and amplitude, using a solid state detector.

  8. Sex-Related Differences in the Effects of Sleep Habits on Verbal and Visuospatial Working Memory

    PubMed Central

    Nakagawa, Seishu; Takeuchi, Hikaru; Taki, Yasuyuki; Nouchi, Rui; Sekiguchi, Atsushi; Kotozaki, Yuka; Miyauchi, Carlos M.; Iizuka, Kunio; Yokoyama, Ryoichi; Shinada, Takamitsu; Yamamoto, Yuki; Hanawa, Sugiko; Araki, Tsuyoshi; Kunitoki, Keiko; Sassa, Yuko; Kawashima, Ryuta

    2016-01-01

    Poor sleep quality negatively affects memory performance, and working memory in particular. We investigated sleep habits related to sleep quality including sleep duration, daytime nap duration, nap frequency, and dream content recall frequency (DCRF). Declarative working memory can be subdivided into verbal working memory (VWM) and visuospatial working memory (VSWM). We hypothesized that sleep habits would have different effects on VWM and VSWM. To our knowledge, our study is the first to investigate differences between VWM and VSWM related to daytime nap duration, nap frequency, and DCRF. Furthermore, we tested the hypothesis that the effects of duration and frequency of daytime naps and DCRF on VWM and VSWM differed according to sex. We assessed 779 healthy right-handed individuals (434 males and 345 females; mean age: 20.7 ± 1.8 years) using a digit span forward and backward VWM task, a forward and backward VSWM task, and sleep habits scales. A correlation analysis was used to test the relationships between VWM capacity (VWMC) and VSWM capacity (VSWMC) scores and sleep duration, nap duration, nap frequency, and DCRF. Furthermore, multiple regression analyses were conducted to identify factors associated with VWMC and VSWMC scores and to identify sex-related differences. We found significant positive correlations between VSWMC and nap duration and DCRF, and between VWMC and sleep duration in all subjects. Furthermore, we found that working memory capacity (WMC) was positively correlated with nap duration in males and with sleep duration in females, and DCRF was positively correlated with VSWMC in females. Our finding of sex-related differences in the effects of sleep habits on WMC has not been reported previously. The associations between WMC and sleep habits differed according to sex because of differences in the underlying neural correlates of VWM and VSWM, and effectiveness of the sleep habits in males and females. PMID:27516751

  9. Sex-Related Differences in the Effects of Sleep Habits on Verbal and Visuospatial Working Memory.

    PubMed

    Nakagawa, Seishu; Takeuchi, Hikaru; Taki, Yasuyuki; Nouchi, Rui; Sekiguchi, Atsushi; Kotozaki, Yuka; Miyauchi, Carlos M; Iizuka, Kunio; Yokoyama, Ryoichi; Shinada, Takamitsu; Yamamoto, Yuki; Hanawa, Sugiko; Araki, Tsuyoshi; Kunitoki, Keiko; Sassa, Yuko; Kawashima, Ryuta

    2016-01-01

    Poor sleep quality negatively affects memory performance, and working memory in particular. We investigated sleep habits related to sleep quality including sleep duration, daytime nap duration, nap frequency, and dream content recall frequency (DCRF). Declarative working memory can be subdivided into verbal working memory (VWM) and visuospatial working memory (VSWM). We hypothesized that sleep habits would have different effects on VWM and VSWM. To our knowledge, our study is the first to investigate differences between VWM and VSWM related to daytime nap duration, nap frequency, and DCRF. Furthermore, we tested the hypothesis that the effects of duration and frequency of daytime naps and DCRF on VWM and VSWM differed according to sex. We assessed 779 healthy right-handed individuals (434 males and 345 females; mean age: 20.7 ± 1.8 years) using a digit span forward and backward VWM task, a forward and backward VSWM task, and sleep habits scales. A correlation analysis was used to test the relationships between VWM capacity (VWMC) and VSWM capacity (VSWMC) scores and sleep duration, nap duration, nap frequency, and DCRF. Furthermore, multiple regression analyses were conducted to identify factors associated with VWMC and VSWMC scores and to identify sex-related differences. We found significant positive correlations between VSWMC and nap duration and DCRF, and between VWMC and sleep duration in all subjects. Furthermore, we found that working memory capacity (WMC) was positively correlated with nap duration in males and with sleep duration in females, and DCRF was positively correlated with VSWMC in females. Our finding of sex-related differences in the effects of sleep habits on WMC has not been reported previously. The associations between WMC and sleep habits differed according to sex because of differences in the underlying neural correlates of VWM and VSWM, and effectiveness of the sleep habits in males and females.

  10. Calling at the highway: The spatiotemporal constraint of road noise on Pacific chorus frog communication.

    PubMed

    Nelson, Danielle V; Klinck, Holger; Carbaugh-Rutland, Alexander; Mathis, Codey L; Morzillo, Anita T; Garcia, Tiffany S

    2017-01-01

    Loss of acoustic habitat due to anthropogenic noise is a key environmental stressor for vocal amphibian species, a taxonomic group that is experiencing global population declines. The Pacific chorus frog ( Pseudacris regilla ) is the most common vocal species of the Pacific Northwest and can occupy human-dominated habitat types, including agricultural and urban wetlands. This species is exposed to anthropogenic noise, which can interfere with vocalizations during the breeding season. We hypothesized that Pacific chorus frogs would alter the spatial and temporal structure of their breeding vocalizations in response to road noise, a widespread anthropogenic stressor. We compared Pacific chorus frog call structure and ambient road noise levels along a gradient of road noise exposures in the Willamette Valley, Oregon, USA. We used both passive acoustic monitoring and directional recordings to determine source level (i.e., amplitude or volume), dominant frequency (i.e., pitch), call duration, and call rate of individual frogs and to quantify ambient road noise levels. Pacific chorus frogs were unable to change their vocalizations to compensate for road noise. A model of the active space and time ("spatiotemporal communication") over which a Pacific chorus frog vocalization could be heard revealed that in high-noise habitats, spatiotemporal communication was drastically reduced for an individual. This may have implications for the reproductive success of this species, which relies on specific call repertoires to portray relative fitness and attract mates. Using the acoustic call parameters defined by this study (frequency, source level, call rate, and call duration), we developed a simplified model of acoustic communication space-time for this species. This model can be used in combination with models that determine the insertion loss for various acoustic barriers to define the impact of anthropogenic noise on the radius of communication in threatened species. Additionally, this model can be applied to other vocal taxonomic groups provided the necessary acoustic parameters are determined, including the frequency parameters and perception thresholds. Reduction in acoustic habitat by anthropogenic noise may emerge as a compounding environmental stressor for an already sensitive taxonomic group.

  11. Preliminary flood-duration frequency estimates using naturalized streamflow records for the Willamette River Basin, Oregon

    USGS Publications Warehouse

    Lind, Greg D.; Stonewall, Adam J.

    2018-02-13

    In this study, “naturalized” daily streamflow records, created by the U.S. Army Corps of Engineers and the Bureau of Reclamation, were used to compute 1-, 3-, 7-, 10-, 15-, 30-, and 60-day annual maximum streamflow durations, which are running averages of daily streamflow for the number of days in each duration. Once the annual maximum durations were computed, the floodduration frequencies could be estimated. The estimated flood-duration frequencies correspond to the 50-, 20-, 10-, 4-, 2-, 1-, 0.5-, and 0.2-percent probabilities of their occurring or being exceeded each year. For this report, the focus was on the Willamette River Basin in Oregon, which is a subbasin of the Columbia River Basin. This study is part of a larger one encompassing the entire Columbia Basin.

  12. Articulation Rate and Its Relationship to Disfluency Type, Duration, and Temperament in Preschool Children Who Stutter

    ERIC Educational Resources Information Center

    Tumanova, Victoria; Zebrowski, Patricia M.; Throneburg, Rebecca N.; Kayikci, Mavis E. Kulak

    2011-01-01

    The purpose of this study was to examine the relationship between articulation rate, frequency and duration of disfluencies of different types, and temperament in preschool children who stutter (CWS). In spontaneous speech samples from 19 CWS (mean age = 3:9; years:months), we measured articulation rate, the frequency and duration of (a) sound…

  13. Validation of simulated earthquake ground motions based on evolution of intensity and frequency content

    USGS Publications Warehouse

    Rezaeian, Sanaz; Zhong, Peng; Hartzell, Stephen; Zareian, Farzin

    2015-01-01

    Simulated earthquake ground motions can be used in many recent engineering applications that require time series as input excitations. However, applicability and validation of simulations are subjects of debate in the seismological and engineering communities. We propose a validation methodology at the waveform level and directly based on characteristics that are expected to influence most structural and geotechnical response parameters. In particular, three time-dependent validation metrics are used to evaluate the evolving intensity, frequency, and bandwidth of a waveform. These validation metrics capture nonstationarities in intensity and frequency content of waveforms, making them ideal to address nonlinear response of structural systems. A two-component error vector is proposed to quantify the average and shape differences between these validation metrics for a simulated and recorded ground-motion pair. Because these metrics are directly related to the waveform characteristics, they provide easily interpretable feedback to seismologists for modifying their ground-motion simulation models. To further simplify the use and interpretation of these metrics for engineers, it is shown how six scalar key parameters, including duration, intensity, and predominant frequency, can be extracted from the validation metrics. The proposed validation methodology is a step forward in paving the road for utilization of simulated ground motions in engineering practice and is demonstrated using examples of recorded and simulated ground motions from the 1994 Northridge, California, earthquake.

  14. Stereotypic Laryngeal and Respiratory Motor Patterns Generate Different Call Types in Rat Ultrasound Vocalization

    PubMed Central

    RIEDE, TOBIAS

    2014-01-01

    Rodents produce highly variable ultrasound whistles as communication signals unlike many other mammals, who employ flow-induced vocal fold oscillations to produce sound. The role of larynx muscles in controlling sound features across different call types in ultrasound vocalization (USV) was investigated using laryngeal muscle electromyographic (EMG) activity, subglottal pressure measurements and vocal sound output in awake and spontaneously behaving Sprague–Dawley rats. Results support the hypothesis that glottal shape determines fundamental frequency. EMG activities of thyroarytenoid and cricothyroid muscles were aligned with call duration. EMG intensity increased with fundamental frequency. Phasic activities of both muscles were aligned with fast changing fundamental frequency contours, for example in trills. Activities of the sternothyroid and sternohyoid muscles, two muscles involved in vocal production in other mammals, are not critical for the production of rat USV. To test how stereotypic laryngeal and respiratory activity are across call types and individuals, sets of ten EMG and subglottal pressure parameters were measured in six different call types from six rats. Using discriminant function analysis, on average 80% of parameter sets were correctly assigned to their respective call type. This was significantly higher than the chance level. Since fundamental frequency features of USV are tightly associated with stereotypic activity of intrinsic laryngeal muscles and muscles contributing to build-up of subglottal pressure, USV provide insight into the neurophysiological control of peripheral vocal motor patterns. PMID:23423862

  15. Imaging different components of a tectonic tremor sequence in southwestern Japan using an automatic statistical detection and location method

    NASA Astrophysics Data System (ADS)

    Poiata, Natalia; Vilotte, Jean-Pierre; Bernard, Pascal; Satriano, Claudio; Obara, Kazushige

    2018-06-01

    In this study, we demonstrate the capability of an automatic network-based detection and location method to extract and analyse different components of tectonic tremor activity by analysing a 9-day energetic tectonic tremor sequence occurring at the downdip extension of the subducting slab in southwestern Japan. The applied method exploits the coherency of multiscale, frequency-selective characteristics of non-stationary signals recorded across the seismic network. Use of different characteristic functions, in the signal processing step of the method, allows to extract and locate the sources of short-duration impulsive signal transients associated with low-frequency earthquakes and of longer-duration energy transients during the tectonic tremor sequence. Frequency-dependent characteristic functions, based on higher-order statistics' properties of the seismic signals, are used for the detection and location of low-frequency earthquakes. This allows extracting a more complete (˜6.5 times more events) and time-resolved catalogue of low-frequency earthquakes than the routine catalogue provided by the Japan Meteorological Agency. As such, this catalogue allows resolving the space-time evolution of the low-frequency earthquakes activity in great detail, unravelling spatial and temporal clustering, modulation in response to tide, and different scales of space-time migration patterns. In the second part of the study, the detection and source location of longer-duration signal energy transients within the tectonic tremor sequence is performed using characteristic functions built from smoothed frequency-dependent energy envelopes. This leads to a catalogue of longer-duration energy sources during the tectonic tremor sequence, characterized by their durations and 3-D spatial likelihood maps of the energy-release source regions. The summary 3-D likelihood map for the 9-day tectonic tremor sequence, built from this catalogue, exhibits an along-strike spatial segmentation of the long-duration energy-release regions, matching the large-scale clustering features evidenced from the low-frequency earthquake's activity analysis. Further examination of the two catalogues showed that the extracted short-duration low-frequency earthquakes activity coincides in space, within about 10-15 km distance, with the longer-duration energy sources during the tectonic tremor sequence. This observation provides a potential constraint on the size of the longer-duration energy-radiating source region in relation with the clustering of low-frequency earthquakes activity during the analysed tectonic tremor sequence. We show that advanced statistical network-based methods offer new capabilities for automatic high-resolution detection, location and monitoring of different scale-components of tectonic tremor activity, enriching existing slow earthquakes catalogues. Systematic application of such methods to large continuous data sets will allow imaging the slow transient seismic energy-release activity at higher resolution, and therefore, provide new insights into the underlying multiscale mechanisms of slow earthquakes generation.

  16. Imaging different components of a tectonic tremor sequence in southwestern Japan using an automatic statistical detection and location method

    NASA Astrophysics Data System (ADS)

    Poiata, Natalia; Vilotte, Jean-Pierre; Bernard, Pascal; Satriano, Claudio; Obara, Kazushige

    2018-02-01

    In this study, we demonstrate the capability of an automatic network-based detection and location method to extract and analyse different components of tectonic tremor activity by analysing a 9-day energetic tectonic tremor sequence occurring at the down-dip extension of the subducting slab in southwestern Japan. The applied method exploits the coherency of multi-scale, frequency-selective characteristics of non-stationary signals recorded across the seismic network. Use of different characteristic functions, in the signal processing step of the method, allows to extract and locate the sources of short-duration impulsive signal transients associated with low-frequency earthquakes and of longer-duration energy transients during the tectonic tremor sequence. Frequency-dependent characteristic functions, based on higher-order statistics' properties of the seismic signals, are used for the detection and location of low-frequency earthquakes. This allows extracting a more complete (˜6.5 times more events) and time-resolved catalogue of low-frequency earthquakes than the routine catalogue provided by the Japan Meteorological Agency. As such, this catalogue allows resolving the space-time evolution of the low-frequency earthquakes activity in great detail, unravelling spatial and temporal clustering, modulation in response to tide, and different scales of space-time migration patterns. In the second part of the study, the detection and source location of longer-duration signal energy transients within the tectonic tremor sequence is performed using characteristic functions built from smoothed frequency-dependent energy envelopes. This leads to a catalogue of longer-duration energy sources during the tectonic tremor sequence, characterized by their durations and 3-D spatial likelihood maps of the energy-release source regions. The summary 3-D likelihood map for the 9-day tectonic tremor sequence, built from this catalogue, exhibits an along-strike spatial segmentation of the long-duration energy-release regions, matching the large-scale clustering features evidenced from the low-frequency earthquake's activity analysis. Further examination of the two catalogues showed that the extracted short-duration low-frequency earthquakes activity coincides in space, within about 10-15 km distance, with the longer-duration energy sources during the tectonic tremor sequence. This observation provides a potential constraint on the size of the longer-duration energy-radiating source region in relation with the clustering of low-frequency earthquakes activity during the analysed tectonic tremor sequence. We show that advanced statistical network-based methods offer new capabilities for automatic high-resolution detection, location and monitoring of different scale-components of tectonic tremor activity, enriching existing slow earthquakes catalogues. Systematic application of such methods to large continuous data sets will allow imaging the slow transient seismic energy-release activity at higher resolution, and therefore, provide new insights into the underlying multi-scale mechanisms of slow earthquakes generation.

  17. Metabolic syndrome, hypertension, and diabetes mellitus after gastric banding: the role of aging and of duration of obesity.

    PubMed

    Pontiroli, Antonio E; Alberto, Morabito; Paganelli, Michele; Saibene, Alessandro; Busetto, Luca

    2013-01-01

    Bariatric surgery leads to resolution of arterial hypertension and diabetes mellitus; isolated reports indicate that response to bariatric surgery is lower in aged patients. The aim of this study was to evaluate the role of age and of duration of obesity on the frequency of co-morbidities in morbid obesity, as well as on improvement of co-morbidities. A total of 837 consecutive patients with known duration of obesity, undergoing gastric banding, were considered for this study; they were divided into quartiles of age and of duration of obesity. Presence of co-morbidities (diabetes mellitus, arterial hypertension, metabolic syndrome), metabolic variables (cholesterol and HDL-C, triglycerides, blood glucose), anthropometric variables, and loss of weight during 24 months were considered. Older patients had a higher frequency of co-morbidities; duration of obesity only affected frequency of co-morbidities, but not response to surgery. At logistic regression, duration of obesity had a moderate independent effect on the frequency of diabetes. Older patients lost less weight than younger patients, but diabetes mellitus and arterial hypertension improved to the same extent in patients of different ages, and metabolic syndrome disappeared more in older patients, associated with a greater decrease of blood glucose. Frequency of removal of gastric banding and loss to follow-up were not different in different quartiles of age or in different quartiles of duration of obesity. Older patients, despite lower weight loss, have a response to bariatric surgery that is similar to that of younger patients; age and duration of obesity should not be considered as limits to indications to bariatric surgery. Copyright © 2013 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  18. Testing inferior colliculus neurons for selectivity to the rate or duration of frequency modulated sweeps

    NASA Astrophysics Data System (ADS)

    Faure, Paul A.; Morrison, James A.; Valdizón-Rodríguez, Roberto

    2018-05-01

    Here we propose a method for testing how the responses of so-called "FM duration-tuned neurons (DTNs)" encode temporal properties of frequency modulated (FM) sweeps to determine if the responses of so-called "FM duration-tuned neurons (DTNs)" are tuned to FM rate or FM duration. Based on previous studies it was unclear if the responses of "FM DTNs" were tuned to signal duration, like pure-tone DTNs, or FM sweep rate. We tested this using single-unit extracellular recording in the inferior colliculus (IC) of the big brown bat (Eptesicus fuscus). We presented IC cells with linear FM sweeps that were varied in FM center frequency (CEF) and spectral bandwidth (BW) to measure the FM rate tuning responses of a cell. We also varied FM signal duration to measure the best duration (BD) and temporal BW of duration tuning of a cell. We then doubled (and halved) the best FM BW, while keeping the CEF constant, and remeasured the BD and temporal BW of duration tuning with FM bandwidth manipulated signals. We reasoned that the range of excitatory signal durations should not change in a true FM DTN whose responses are tuned to signal duration; however, when stimulated with bandwidth manipulated FM sounds the range of excitatory signal durations should predictably vary in a FM rate-tuned cell. Preliminary data indicate that our stimulus paradigm can disambiguate whether the evoked responses of an IC neuron are FM sweep rate tuned or FM duration tuned.

  19. WHO European Childhood Obesity Surveillance Initiative: associations between sleep duration, screen time and food consumption frequencies.

    PubMed

    Börnhorst, Claudia; Wijnhoven, Trudy M A; Kunešová, Marie; Yngve, Agneta; Rito, Ana I; Lissner, Lauren; Duleva, Vesselka; Petrauskiene, Ausra; Breda, João

    2015-04-30

    Both sleep duration and screen time have been suggested to affect children's diet, although in different directions and presumably through different pathways. The present cross-sectional study aimed to simultaneously investigate the associations between sleep duration, screen time and food consumption frequencies in children. The analysis was based on 10 453 children aged 6-9 years from five European countries that participated in the World Health Organization European Childhood Obesity Surveillance Initiative. Logistic multilevel models were used to assess associations of parent-reported screen time as well as sleep duration (exposure variables) with consumption frequencies of 16 food items (outcome variables). All models were adjusted for age, sex, outdoor play time, maximum educational level of parents and sleep duration or screen time, depending on the exposure under investigation. One additional hour of screen time was associated with increased consumption frequencies of 'soft drinks containing sugar' (1.28 [1.19;1.39]; odds ratio and 99% confidence interval), 'diet/light soft drinks' (1.21 [1.14;1.29]), 'flavoured milk' (1.18 [1.08;1.28]), 'candy bars or chocolate' (1.31 [1.22;1.40]), 'biscuits, cakes, doughnuts or pies' (1.22 [1.14;1.30]), 'potato chips (crisps), corn chips, popcorn or peanuts' (1.32 [1.20;1.45]), 'pizza, French fries (chips), hamburgers'(1.30 [1.18;1.43]) and with a reduced consumption frequency of 'vegetables (excluding potatoes)' (0.89 [0.83;0.95]) and 'fresh fruits' (0.91 [0.86;0.97]). Conversely, one additional hour of sleep duration was found to be associated with increased consumption frequencies of 'fresh fruits' (1.11 [1.04;1.18]) and 'vegetables (excluding potatoes)' (1.14 [1.07;1.23]). The results suggest a potential relation between high screen time exposure and increased consumption frequencies of foods high in fat, free sugar or salt whereas long sleep duration may favourably be related to children's food choices. Both screen time and sleep duration are modifiable behaviours that may be tackled in childhood obesity prevention efforts.

  20. An Analysis of The Parameters Used In Speech ABR Assessment Protocols.

    PubMed

    Sanfins, Milaine D; Hatzopoulos, Stavros; Donadon, Caroline; Diniz, Thais A; Borges, Leticia R; Skarzynski, Piotr H; Colella-Santos, Maria Francisca

    2018-04-01

    The aim of this study was to assess the parameters of choice, such as duration, intensity, rate, polarity, number of sweeps, window length, stimulated ear, fundamental frequency, first formant, and second formant, from previously published speech ABR studies. To identify candidate articles, five databases were assessed using the following keyword descriptors: speech ABR, ABR-speech, speech auditory brainstem response, auditory evoked potential to speech, speech-evoked brainstem response, and complex sounds. The search identified 1288 articles published between 2005 and 2015. After filtering the total number of papers according to the inclusion and exclusion criteria, 21 studies were selected. Analyzing the protocol details used in 21 studies suggested that there is no consensus to date on a speech-ABR protocol and that the parameters of analysis used are quite variable between studies. This inhibits the wider generalization and extrapolation of data across languages and studies.

  1. Transcranial electric and magnetic stimulation: technique and paradigms.

    PubMed

    Paulus, Walter; Peterchev, Angel V; Ridding, Michael

    2013-01-01

    Transcranial electrical and magnetic stimulation techniques encompass a broad physical variety of stimuli, ranging from static magnetic fields or direct current stimulation to pulsed magnetic or alternating current stimulation with an almost infinite number of possible stimulus parameters. These techniques are continuously refined by new device developments, including coil or electrode design and flexible control of the stimulus waveforms. They allow us to influence brain function acutely and/or by inducing transient plastic after-effects in a range from minutes to days. Manipulation of stimulus parameters such as pulse shape, intensity, duration, and frequency, and location, size, and orientation of the electrodes or coils enables control of the immediate effects and after-effects. Physiological aspects such as stimulation at rest or during attention or activation may alter effects dramatically, as does neuropharmacological drug co-application. Non-linear relationships between stimulus parameters and physiological effects have to be taken into account. © 2013 Elsevier B.V. All rights reserved.

  2. Impact of xylomethazoline on eustachian tube function in healthy participants.

    PubMed

    Meyer, Moritz F; Mikolajczak, Stefanie; Korthäuer, Christine; Jumah, Masen D; Hahn, Moritz; Grosheva, Maria; Lüers, Jan-Christoffer; Hüttenbrink, Karl-Bernd; Beutner, Dirk

    2015-06-01

    The use of decongestants is common in otitis media eustachian tube (ET) dysfunction. However, the underlying mechanism and the type of action on the complex middle ear pressure equalization system are poorly understood. Here, by use of the pressure chamber, we investigated the impact of intranasal decongestive therapy (xylomethazoline) on ET function. Thirty healthy participants (60 ears) were exposed to a predetermined profile of phases of compression and decompression in a hypobaric and hyperbaric pressure chamber. ET opening pressure, ET opening duration, ET opening frequency, and ET closing pressure were determined before and after intranasal application of xylomethazoline. A significantly higher number of ET openings (ET opening frequency) in passive equalization condition could be measured after application of decongestants than before. No significant difference could be found in the values of ET opening pressure, ET opening duration, and ET closing pressure parameters before in comparison with the values after application of xylomethazoline. We conclude that xylomethazoline might only have a minor effect during active and passive middle ear pressure equalization. Larger cohorts and targeted application of decongestants should be tested to confirm these preliminary data and to find new evidence on the effects of decongestants.

  3. Study of acoustic correlates associate with emotional speech

    NASA Astrophysics Data System (ADS)

    Yildirim, Serdar; Lee, Sungbok; Lee, Chul Min; Bulut, Murtaza; Busso, Carlos; Kazemzadeh, Ebrahim; Narayanan, Shrikanth

    2004-10-01

    This study investigates the acoustic characteristics of four different emotions expressed in speech. The aim is to obtain detailed acoustic knowledge on how a speech signal is modulated by changes from neutral to a certain emotional state. Such knowledge is necessary for automatic emotion recognition and classification and emotional speech synthesis. Speech data obtained from two semi-professional actresses are analyzed and compared. Each subject produces 211 sentences with four different emotions; neutral, sad, angry, happy. We analyze changes in temporal and acoustic parameters such as magnitude and variability of segmental duration, fundamental frequency and the first three formant frequencies as a function of emotion. Acoustic differences among the emotions are also explored with mutual information computation, multidimensional scaling and acoustic likelihood comparison with normal speech. Results indicate that speech associated with anger and happiness is characterized by longer duration, shorter interword silence, higher pitch and rms energy with wider ranges. Sadness is distinguished from other emotions by lower rms energy and longer interword silence. Interestingly, the difference in formant pattern between [happiness/anger] and [neutral/sadness] are better reflected in back vowels such as /a/(/father/) than in front vowels. Detailed results on intra- and interspeaker variability will be reported.

  4. Locomotor, cardiocirculatory and metabolic adaptations to training in Andalusian and Anglo-Arabian horses.

    PubMed

    Muñoz, A; Santisteban, R; Rubio, M D; Agüera, E I; Escribano, B M; Castejón, F M

    1999-02-01

    The effects of two training programmes in 20 Andalusian and 12 Anglo-Arabian horses were evaluated by an increasing intensity work test at velocities of 4, 5, 6, 7 and 8 m sec(-1). Heart rate was monitored and blood samples were drawn at rest and after each velocity to analyse packed cell volume, haemoglobin concentration, plasma lactate and potassium levels. Furthermore, the programmes were video-taped and stride length, duration and frequency, stance (restraint and propulsion), swing phase durations and stride vertical component were measured. The training protocol of the Andalusian horses produced significant decreases in the cardiovascular, haematological and metabolic responses to exercise. Locomotory training adaptation consisted of an increased stride frequency and a reduced stride length and vertical stride component. The last variable was the limiting factor of stride length both before and after training in the Andalusian horses. A different training protocol for show-jumping competition in Anglo-Arabian horses failed to show significant differences in the studied parameters to the work test, although an increase in stride length at velocities of over 6 m sec(-1) was observed. Stride vertical component did not have an effect on the physiological response to exercise, either before or after training.

  5. Effects of prolonged exposure of lettuce seeds to HZE particles on orbital stations

    NASA Astrophysics Data System (ADS)

    Nevzgodina, L. V.; Maksimova, E. N.; Kaminskaya, E. V.

    In a study of the biological effects of cosmic HZE particles, lettuce (Lactuca sativa) seeds were flown on the orbital stations Salyut 6 and 7 for varying periods of time (from 40 to 457 days). The dependence of the biological damage on flight duration, physical parameters and the fact of passage of an HZE particle through the seed was estimated using the criterion of the frequency of aberrant cells. The arrangement of the flight biological container Biobloc made it possible to trace the location of tracks of individual HZE particles with Z>=6 and LET 200 keV/um. In seeds hit by HZE particles, for all exposure times, a statistically significant much higher yield of aberrant cells and also of cells containing multiple chromosome aberrations was observed than in the control material. The frequency of aberrant cells is markedly higher (by a factor of 1,5) in seeds hit than in non-hit ones. The changes of the yield of aberrant cells as a function of the absorbed dose (3.2-63.4 mGy) and the fluence (4.8-44.2 particles/cm2) are linear for the exposure duration ranging from 40 to 457 days.

  6. RF Microalgal lipid content characterization

    PubMed Central

    Ahmad, Mahmoud Al; Al-Zuhair, Sulaiman; Taher, Hanifa; Hilal-Alnaqbi, Ali

    2014-01-01

    Most conventional techniques for the determination of microalgae lipid content are time consuming and in most cases are indirect and require excessive sample preparations. This work presents a new technique that utilizes radio frequency (RF) for rapid lipid quantification, without the need for sample preparation. Tests showed that a shift in the resonance frequency of a RF open-ended coaxial resonator and a gradual increase in its resonance magnitude may occur as the lipids content of microalgae cells increases. These response parameters can be then calibrated against actual cellular lipid contents and used for rapid determination of the cellular lipids. The average duration of lipid quantification using the proposed technique was of about 1 minute, which is significantly less than all other conventional techniques, and was achieved without the need for any time consuming treatment steps. PMID:24870372

  7. Widely tunable mid-infrared fiber laser source based on soliton self-frequency shift in microstructured tellurite fiber.

    PubMed

    Koptev, M Yu; Anashkina, E A; Andrianov, A V; Dorofeev, V V; Kosolapov, A F; Muravyev, S V; Kim, A V

    2015-09-01

    A turnkey fiber laser source generating high-quality pulses with a spectral sech shape and Fourier transform-limited duration of order 100 fs widely tunable in the 1.6-2.65 μm range is presented. It is based on Raman soliton self-frequency shifting in the suspended-core microstructured TeO2-WO3-La2O3 glass fiber pumped by a hybrid Er/Tm fiber system. Detailed experimental and theoretical studies, which are in a very good agreement, of nonlinear pulse dynamics in the tellurite fiber with carefully measured and calculated parameters are reported. A quantitatively verified numerical model is used to show Raman soliton shift in the range well beyond 3 μm for increased pump energy.

  8. Magnetoencephalographic recording of auditory mismatch negativity in response to duration and frequency deviants in a single session in patients with schizophrenia.

    PubMed

    Suga, Motomu; Nishimura, Yukika; Kawakubo, Yuki; Yumoto, Masato; Kasai, Kiyoto

    2016-07-01

    Auditory mismatch negativity (MMN) and its magnetoencephalographic (MEG) counterpart (MMNm) are an established biological index in schizophrenia research. MMN in response to duration and frequency deviants may have differential relevance to the pathophysiology and clinical stages of schizophrenia. MEG has advantage in that it almost purely detects MMNm arising from the auditory cortex. However, few previous MEG studies on schizophrenia have simultaneously assessed MMNm in response to duration and frequency deviants or examined the effect of chronicity on the group difference. Forty-two patients with chronic schizophrenia and 74 matched control subjects participated in the study. Using a whole-head MEG, MMNm in response to duration and frequency deviants of tones was recorded while participants passively listened to an auditory sequence. Compared to healthy subjects, patients with schizophrenia exhibited significantly reduced powers of MMNm in response to duration deviant in both hemispheres, whereas MMNm in response to frequency deviant did not differ between the two groups. These results did not change according to the chronicity of the illness. These results, obtained by using a sequence-enabling simultaneous assessment of both types of MMNm, suggest that MEG recording of MMN in response to duration deviant may be a more sensitive biological marker of schizophrenia than MMN in response to frequency deviant. Our findings represent an important first step towards establishment of MMN as a biomarker for schizophrenia in real-world clinical psychiatry settings. © 2016 The Authors. Psychiatry and Clinical Neurosciences © 2016 Japanese Society of Psychiatry and Neurology.

  9. Accounting for nonmonotonic precursor duration effects with gain reduction in the temporal window model.

    PubMed

    Roverud, Elin; Strickland, Elizabeth A

    2014-03-01

    The mechanisms of forward masking are not clearly understood. The temporal window model (TWM) proposes that masking occurs via a neural mechanism that integrates within a temporal window. The medial olivocochlear reflex (MOCR), a sound-evoked reflex that reduces cochlear amplifier gain, may also contribute to forward masking if the preceding sound reduces gain for the signal. Psychophysical evidence of gain reduction can be observed using a growth of masking (GOM) paradigm with an off-frequency forward masker and a precursor. The basilar membrane input/output (I/O) function is estimated from the GOM function, and the I/O function gain is reduced by the precursor. In this study, the effect of precursor duration on this gain reduction effect was examined for on- and off-frequency precursors. With on-frequency precursors, thresholds increased with increasing precursor duration, then decreased (rolled over) for longer durations. Thresholds with off-frequency precursors continued to increase with increasing precursor duration. These results are not consistent with solely neural masking, but may reflect gain reduction that selectively affects on-frequency stimuli. The TWM was modified to include history-dependent gain reduction to simulate the MOCR, called the temporal window model-gain reduction (TWM-GR). The TWM-GR predicted rollover and the differences with on- and off-frequency precursors whereas the TWM did not.

  10. The effect of signal duration on the underwater detection thresholds of a harbor porpoise (Phocoena phocoena) for single frequency-modulated tonal signals between 0.25 and 160 kHz.

    PubMed

    Kastelein, Ronald A; Hoek, Lean; de Jong, Christ A F; Wensveen, Paul J

    2010-11-01

    The underwater hearing sensitivity of a young male harbor porpoise for tonal signals of various signal durations was quantified by using a behavioral psychophysical technique. The animal was trained to respond only when it detected an acoustic signal. Fifty percent detection thresholds were obtained for tonal signals (15 frequencies between 0.25-160 kHz, durations 0.5-5000 ms depending on the frequency; 134 frequency-duration combinations in total). Detection thresholds were quantified by varying signal amplitude by the 1-up 1-down staircase method. The hearing thresholds increased when the signal duration fell below the time constant of integration. The time constants, derived from an exponential model of integration [Plomp and Bouman, J. Acoust. Soc. Am. 31, 749-758 (1959)], varied from 629 ms at 2 kHz to 39 ms at 64 kHz. The integration times of the porpoises were similar to those of other mammals including humans, even though the porpoise is a marine mammal and a hearing specialist. The results enable more accurate estimations of the distances at which porpoises can detect short-duration environmental tonal signals. The audiogram thresholds presented by Kastelein et al. [J. Acoust. Soc. Am. 112, 334-344 (2002)], after correction for the frequency bandwidth of the FM signals, are similar to the results of the present study for signals of 1500 ms duration. Harbor porpoise hearing is more sensitive between 2 and 10 kHz, and less sensitive above 10 kHz, than formerly believed.

  11. Bivariate frequency analysis of rainfall intensity and duration for urban stormwater infrastructure design

    NASA Astrophysics Data System (ADS)

    Jun, Changhyun; Qin, Xiaosheng; Gan, Thian Yew; Tung, Yeou-Koung; De Michele, Carlo

    2017-10-01

    This study presents a storm-event based bivariate frequency analysis approach to determine design rainfalls in which, the number, intensity and duration of actual rainstorm events were considered. To derive more realistic design storms, the occurrence probability of an individual rainstorm event was determined from the joint distribution of storm intensity and duration through a copula model. Hourly rainfall data were used at three climate stations respectively located in Singapore, South Korea and Canada. It was found that the proposed approach could give a more realistic description of rainfall characteristics of rainstorm events and design rainfalls. As results, the design rainfall quantities from actual rainstorm events at the three studied sites are consistently lower than those obtained from the conventional rainfall depth-duration-frequency (DDF) method, especially for short-duration storms (such as 1-h). It results from occurrence probabilities of each rainstorm event and a different angle for rainfall frequency analysis, and could offer an alternative way of describing extreme rainfall properties and potentially help improve the hydrologic design of stormwater management facilities in urban areas.

  12. Rules of parameter variation in homotype series of birdsong can indicate a 'sollwert' significance.

    PubMed

    Hultsch, H; Todt, D

    1996-11-01

    Various bird species produce songs which include homotype pattern series, i.e. segments composed of a number of repeated vocal units. We compared such units and analyzed the variation of their parameters, especially in the time and the frequency domain. In addition, we examined whether and how serial changes of both the range and the trend of variation were related to song constituents following the repetitions. Data evaluation showed that variation of specific serial parameters (e.g., unit pitch or unit duration) occurring in the whistle song-types of nightingales (Luscinia megarhynchos) were converging towards a distinct terminal value. Although song-types differed in this terminal value, it was found to play the role of a key cue ('sollwert'). The continuation of a song depended on a preceding attainment of its specific 'sollwert'. Our results suggest that the study of signal parameters and rules of their variations make a useful tool for the behavioral access to the properties of the control systems mediating serial signal performances.

  13. Vocalization frequency and duration are coded in separate hindbrain nuclei.

    PubMed

    Chagnaud, Boris P; Baker, Robert; Bass, Andrew H

    2011-06-14

    Temporal patterning is an essential feature of neural networks producing precisely timed behaviours such as vocalizations that are widely used in vertebrate social communication. Here we show that intrinsic and network properties of separate hindbrain neuronal populations encode the natural call attributes of frequency and duration in vocal fish. Intracellular structure/function analyses indicate that call duration is encoded by a sustained membrane depolarization in vocal prepacemaker neurons that innervate downstream pacemaker neurons. Pacemaker neurons, in turn, encode call frequency by rhythmic, ultrafast oscillations in their membrane potential. Pharmacological manipulations show prepacemaker activity to be independent of pacemaker function, thus accounting for natural variation in duration which is the predominant feature distinguishing call types. Prepacemaker neurons also innervate key hindbrain auditory nuclei thereby effectively serving as a call-duration corollary discharge. We propose that premotor compartmentalization of neurons coding distinct acoustic attributes is a fundamental trait of hindbrain vocal pattern generators among vertebrates.

  14. Vocalization frequency and duration are coded in separate hindbrain nuclei

    PubMed Central

    Chagnaud, Boris P.; Baker, Robert; Bass, Andrew H.

    2011-01-01

    Temporal patterning is an essential feature of neural networks producing precisely timed behaviours such as vocalizations that are widely used in vertebrate social communication. Here we show that intrinsic and network properties of separate hindbrain neuronal populations encode the natural call attributes of frequency and duration in vocal fish. Intracellular structure/function analyses indicate that call duration is encoded by a sustained membrane depolarization in vocal prepacemaker neurons that innervate downstream pacemaker neurons. Pacemaker neurons, in turn, encode call frequency by rhythmic, ultrafast oscillations in their membrane potential. Pharmacological manipulations show prepacemaker activity to be independent of pacemaker function, thus accounting for natural variation in duration which is the predominant feature distinguishing call types. Prepacemaker neurons also innervate key hindbrain auditory nuclei thereby effectively serving as a call-duration corollary discharge. We propose that premotor compartmentalization of neurons coding distinct acoustic attributes is a fundamental trait of hindbrain vocal pattern generators among vertebrates. PMID:21673667

  15. CELL POPULATION KINETICS OF EXCISED ROOTS OF PISUM SATIVUM

    PubMed Central

    Van't Hof, Jack

    1965-01-01

    The cell population kinetics of excised, cultured pea roots was studied with the use of tritiated thymidine and colchicine to determine (1) the influence of excision, (2) the influence of sucrose concentration, (3) the average mitotic cycle duration, and (4) the duration of mitosis and the G 1, S, and G 2 periods of interphase.1 The results indicate that the process of excision causes a drop in the frequency of mitotic figures when performed either at the beginning of the culture period or after 100 hours in culture. This initial decrease in frequency of cell division is independent of sucrose concentration, but the subsequent rise in frequency of division, after 12 hours in culture, is dependent upon sucrose concentration. Two per cent sucrose maintains the shortest mitotic cycle duration. The use of colchicine indicated an average cycle duration of 20 hours, whereas the use of tritiated thymidine produced an average cycle duration of 17 hours. PMID:5857253

  16. The influence of inertial sensor sampling frequency on the accuracy of measurement parameters in rearfoot running.

    PubMed

    Mitschke, Christian; Zaumseil, Falk; Milani, Thomas L

    2017-11-01

    Increasingly, inertial sensors are being used for running analyses. The aim of this study was to systematically investigate the influence of inertial sensor sampling frequencies (SF) on the accuracy of kinematic, spatio-temporal, and kinetic parameters. We hypothesized that running analyses at lower SF result in less signal information and therefore the inability to sufficiently interpret measurement data. Twenty-one subjects participated in this study. Rearfoot strikers ran on an indoor running track at a velocity of 3.5 ± 0.1 ms -1 . A uniaxial accelerometer was attached at the tibia and an inertial measurement unit was mounted at the heel of the right shoe. All sensors were synchronized at the start and data was measured with 1000 Hz (reference SF). Datasets were reduced to 500, 333, 250, 200, and 100 Hz in post-processing. The results of this study showed that a minimum SF of 500 Hz should be used to accurately measure kinetic parameters (e.g. peak heel acceleration). In contrast, stride length showed accurate results even at 333 Hz. 200 Hz were required to calculate parameters accurately for peak tibial acceleration, stride duration, and all kinematic measurements. The information from this study is necessary to correctly interpret measurement data of existing investigations and to plan future studies.

  17. Effects of shape and stroke parameters on the propulsion performance of an axisymmetric swimmer.

    PubMed

    Peng, Jifeng; Alben, Silas

    2012-03-01

    In nature, there exists a special group of aquatic animals which have an axisymmetric body and whose primary swimming mechanism is to use periodic body contractions to generate vortex rings in the surrounding fluid. Using jellyfish medusae as an example, this study develops a mathematical model of body kinematics of an axisymmetric swimmer and uses a computational approach to investigate the induced vortex wakes. Wake characteristics are identified for swimmers using jet propulsion and rowing, two mechanisms identified in previous studies of medusan propulsion. The parameter space of body kinematics is explored through four quantities: a measure of body shape, stroke amplitude, the ratio between body contraction duration and extension duration, and the pulsing frequency. The effects of these parameters on thrust, input power requirement and circulation production are quantified. Two metrics, cruising speed and energy cost of locomotion, are used to evaluate the propulsion performance. The study finds that a more prolate-shaped swimmer with larger stroke amplitudes is able to swim faster, but its cost of locomotion is also higher. In contrast, a more oblate-shaped swimmer with smaller stroke amplitudes uses less energy for its locomotion, but swims more slowly. Compared with symmetric strokes with equal durations of contraction and extension, faster bell contractions increase the swimming speed whereas faster bell extensions decrease it, but both require a larger energy input. This study shows that besides the well-studied correlations between medusan body shape and locomotion, stroke variables also affect the propulsion performance. It provides a framework for comparing the propulsion performance of axisymmetric swimmers based on their body kinematics when it is difficult to measure and analyze their wakes empirically. The knowledge from this study is also useful for the design of robotic swimmers that use axisymmetric body contractions for propulsion.

  18. The accuracy of eyelid movement parameters for drowsiness detection.

    PubMed

    Wilkinson, Vanessa E; Jackson, Melinda L; Westlake, Justine; Stevens, Bronwyn; Barnes, Maree; Swann, Philip; Rajaratnam, Shantha M W; Howard, Mark E

    2013-12-15

    Drowsiness is a major risk factor for motor vehicle and occupational accidents. Real-time objective indicators of drowsiness could potentially identify drowsy individuals with the goal of intervening before an accident occurs. Several ocular measures are promising objective indicators of drowsiness; however, there is a lack of studies evaluating their accuracy for detecting behavioral impairment due to drowsiness in real time. In this study, eye movement parameters were measured during vigilance tasks following restricted sleep and in a rested state (n = 33 participants) at three testing points (n = 71 data points) to compare ocular measures to a gold standard measure of drowsiness (OSLER). The utility of these parameters for detecting drowsiness-related errors was evaluated using receiver operating characteristic curves (ROC) (adjusted by clustering for participant) and identification of optimal cutoff levels for identifying frequent drowsiness-related errors (4 missed signals in a minute using OSLER). Their accuracy was tested for detecting increasing frequencies of behavioral lapses on a different task (psychomotor vigilance task [PVT]). Ocular variables which measured the average duration of eyelid closure (inter-event duration [IED]) and the ratio of the amplitude to velocity of eyelid closure were reliable indicators of frequent errors (area under the curve for ROC of 0.73 to 0.83, p < 0.05). IED produced a sensitivity and specificity of 71% and 88% for detecting ≥ 3 lapses (PVT) in a minute and 100% and 86% for ≥ 5 lapses. A composite measure of several eye movement characteristics (Johns Drowsiness Scale) provided sensitivities of 77% and 100% for detecting 3 and ≥ 5 lapses in a minute, with specificities of 85% and 83%, respectively. Ocular measures, particularly those measuring the average duration of episodes of eye closure are promising real-time indicators of drowsiness.

  19. Opposite effects of high- and low-frequency transcranial random noise stimulation probed with visual motion adaptation

    PubMed Central

    Campana, Gianluca; Camilleri, Rebecca; Moret, Beatrice; Ghin, Filippo; Pavan, Andrea

    2016-01-01

    Transcranial random noise stimulation (tRNS) is a recent neuro-modulation technique whose effects at both behavioural and neural level are still debated. Here we employed the well-known phenomenon of motion after-effect (MAE) in order to investigate the effects of high- vs. low-frequency tRNS on motion adaptation and recovery. Participants were asked to estimate the MAE duration following prolonged adaptation (20 s) to a complex moving pattern, while being stimulated with either sham or tRNS across different blocks. Different groups were administered with either high- or low-frequency tRNS. Stimulation sites were either bilateral human MT complex (hMT+) or frontal areas. The results showed that, whereas no effects on MAE duration were induced by stimulating frontal areas, when applied to the bilateral hMT+, high-frequency tRNS caused a significant decrease in MAE duration whereas low-frequency tRNS caused a significant corresponding increase in MAE duration. These findings indicate that high- and low-frequency tRNS have opposed effects on the adaptation-dependent unbalance between neurons tuned to opposite motion directions, and thus on neuronal excitability. PMID:27934947

  20. Harbor Seal (Phoca vitulina) Reproductive Advertisement Behavior and the Effects of Vessel Noise

    NASA Astrophysics Data System (ADS)

    Matthews, Leanna P.

    Harbor seals (Phoca vitulina) are a widely distributed pinniped species that mate underwater. Similar to other aquatically mating pinnipeds, male harbor seals produce vocalizations during the breeding season that function in male-male interactions and possibly as an attractant for females. I investigated multiple aspects of these reproductive advertisement displays in a population of harbor seals in Glacier Bay National Park and Preserve, Alaska. First, I looked at vocal production as a function of environmental variables, including season, daylight, and tidal state. Vocalizations were highly seasonal and detection of these vocalizations peaked in June and July, which correspond with the estimated time of breeding. Vocalizations also varied with light, with the lowest probability of detection during the day and the highest probability of detection at night. The high probability of detection corresponded to when females are known to forage. These results are similar to the vocal behavior of previously studied populations. However, unlike previously studied populations, the detection of harbor seal breeding vocalizations did not vary with tidal state. This is likely due to the location of the hydrophone, as it was not near the haul out and depth was therefore not significantly influenced by changes in tidal height. I also investigated the source levels and call parameters of vocalizations, as well as call rate and territoriality. The average source level of harbor seal breeding vocalizations was 144 dB re 1 ?Pa at 1 m and measurements ranged from 129 to 149 dB re 1 ?Pa. Analysis of call parameters indicated that vocalizations of harbor seals in Glacier Bay were similar in duration to other populations, but were much lower in frequency. During the breeding season, there were two discrete calling areas that likely represent two individual males; the average call rate in these display areas was approximately 1 call per minute. The harbor seal breeding season also overlaps with peak tourism in Glacier Bay, and the majority of tourists visit the park on a motorized vessel. Because of this overlap, I investigated the impacts of vessel noise on the vocal behavior of individual males. In the presence of vessel noise, male harbor seals increase the amplitude of their vocalizations, decrease the duration, and increase the minimum frequency. These vocal shifts are similar to studies of noise impacts on other species across taxa, but it is unknown how this could impact the reproductive success of male harbor seals. Finally, I looked at the role of female preference for male vocalizations. Using playbacks of male vocalizations to captive female harbor seals, I found that females have a higher response to vocalizations that correspond to dominant males. Females were less responsive to subordinate male vocalizations, which had a shorter duration and a higher frequency. Given that male harbor seals decrease the duration and increase the frequency of vocalizations in the presence of noise, it is possible that these vocalizations become less attractive in noise.

  1. Smart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation.

    PubMed

    Massaroni, Carlo; Venanzi, Cecilia; Silvatti, Amanda P; Lo Presti, Daniela; Saccomandi, Paola; Formica, Domenico; Giurazza, Francesco; Caponero, Michele A; Schena, Emiliano

    2018-05-01

    The use of wearable systems for monitoring vital parameters has gained wide popularity in several medical fields. The focus of the present study is the experimental assessment of a smart textile based on 12 fiber Bragg grating sensors for breathing monitoring and thoraco-abdominal motion pattern analysis. The feasibility of the smart textile for monitoring several temporal respiratory parameters (ie, breath-by-breath respiratory period, breathing frequency, duration of inspiratory and expiratory phases), volume variations of the whole chest wall and of its compartments is performed on 8 healthy male volunteers. Values gathered by the textile are compared to the data obtained by a motion analysis system, used as the reference instrument. Good agreement between the 2 systems on both respiratory period (bias of 0.01 seconds), breathing frequency (bias of -0.02 breaths/min) and tidal volume (bias of 0.09 L) values is demonstrated. Smart textile shows good performance in the monitoring of thoraco-abdominal pattern and its variation, as well. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Electron acceleration from rest to GeV energy by chirped axicon Gaussian laser pulse in vacuum in the presence of wiggler magnetic field

    NASA Astrophysics Data System (ADS)

    Kant, Niti; Rajput, Jyoti; Singh, Arvinder

    2018-03-01

    This paper presents a scheme of electron energy enhancement by employing frequency - chirped lowest order axicon focussed radially polarised (RP) laser pulse in vacuum under the influence of wiggler magnetic field. Terawatt RP laser can be focussed down to ∼5μm by an axicon optical element, which produces an intense longitudinal electric field. This unique property of axicon focused Gaussian RP laser pulse is employed for direct electron acceleration in vacuum. A linear frequency chirp increases the time duration of laser-electron interaction, whereas, the applied magnetic wiggler helps in improving the strength of ponderomotive force v→ ×B→ and periodically deflects electron in order to keep it traversing in the accelerating phase up to longer distance. Numerical simulations have been carried out to investigate the influence of laser, frequency chirp and magnetic field parameters on electron energy enhancement. It is noticed that an electron from rest can be accelerated up to GeV energy under optimized laser and magnetic field parameters. Significant enhancement in the electron energy gain of the order of 11.2 GeV is observed with intense chirped laser pulse in the presence of wiggler magnetic field of strength 96.2 kG.

  3. Systematic studies of modified vocalization: effects of speech rate and instatement style during metronome stimulation.

    PubMed

    Davidow, Jason H; Bothe, Anne K; Richardson, Jessica D; Andreatta, Richard D

    2010-12-01

    This study introduces a series of systematic investigations intended to clarify the parameters of the fluency-inducing conditions (FICs) in stuttering. Participants included 11 adults, aged 20-63 years, with typical speech-production skills. A repeated measures design was used to examine the relationships between several speech production variables (vowel duration, voice onset time, fundamental frequency, intraoral pressure, pressure rise time, transglottal airflow, and phonated intervals) and speech rate and instatement style during metronome-entrained rhythmic speech. Measures of duration (vowel duration, voice onset time, and pressure rise time) differed across different metronome conditions. When speech rates were matched between the control condition and metronome condition, voice onset time was the only variable that changed. Results confirm that speech rate and instatement style can influence speech production variables during the production of fluency-inducing conditions. Future studies of normally fluent speech and of stuttered speech must control both features and should further explore the importance of voice onset time, which may be influenced by rate during metronome stimulation in a way that the other variables are not.

  4. Excitation of atoms and ions in plasmas by ultra-short electromagnetic pulses

    NASA Astrophysics Data System (ADS)

    Astapenko, V. A.; Sakhno, S. V.; Svita, S. Yu; Lisitsa, V. S.

    2017-02-01

    The problem of atoms and ions diagnostics in rarefied and dense plasmas by ultrashort laser pulses (USP) is under consideration. The application of USP provides: 1) excitation from ground states due to their carrier frequency high enough, 2) penetration into optically dense media due to short pulses duration. The excitation from ground atomic states increases sharply populations of excited atomic states in contrast with standard laser induced fluorescence spectroscopy based on radiative transitions between excited atomic states. New broadening parameter in radiation absorption, namely inverse pulse duration time 1/τ appears in addition to standard line-shape width in the profile G(ω). The Lyman-beta absorption spectra for USP are calculated for Holtsmark static broadening mechanism. Excitation of highly charged H-like ions in hot plasmas is described by both Gaussian shapes for Doppler broadening and pulse spectrum resulting in analytical absorption line-shape. USP penetration into optically thick media and corresponding excitation probability are calculated. It is shown a great effect of USP duration on excitation probabilities in optically thick media. The typical situations for plasma diagnostics by USP are discussed in details.

  5. Changes in buccal micronucleus cytome parameters associated with smokeless tobacco and pesticide exposure among female tea garden workers of Assam, India.

    PubMed

    Kausar, Afifa; Giri, Sarbani; Roy, Prasenjit; Giri, Anirudha

    2014-03-01

    Assam is the highest tea producing state in India. A large number of workers are engaged in various units of tea industry. There are few reports on the health status of the tea garden workers. The present cytogenetic biomonitoring study was undertaken to investigate the genotoxic effect associated with workers in tea industries in southern Assam. Smokeless tobacco chewing along with betel nut is very common practice among the workers. Workers also get exposed periodically to mixture of pesticides. Employing buccal micronucleus cytome assay, exfoliated buccal cells were analyzed in 90 female tea garden and compared to 90 age and sex matched non-chewer control as well as 70 chewers who are not tea garden workers. Statistically significant (p<0.001) increase in genotoxic and cell death parameters was observed in tea garden workers compared to both the control groups. The frequency of cell proliferation biomarkers was highest in the chewer controls whereas genotoxic and cell death parameters were highest in tea garden workers. Linear correlation analysis revealed strong positive correlation between the duration of occupation and the frequency of micronucleus (r=0.597; p<0.001) as well as cell death parameters (r=0.588; p<0.001). Amount of chewing also had significant positive correlation with micronucleus frequency (r=0.243 or 5.9%; p<0.05) and cell death parameters (r=0.217; p<0.05). A statistically significant decrease in total RBC count, haemoglobin content as well as acetylcholine esterase in the blood of exposed individuals was observed. The average BMI among the tea garden workers was relatively lower compared to the control group. Pesticide exposure and chewing areca nut along with smokeless tobacco use may be responsible for changes in cytome parameters in exfoliated buccal cells. Copyright © 2013 Elsevier GmbH. All rights reserved.

  6. Vagus nerve stimulation in 15 children with therapy resistant epilepsy; its impact on cognition, quality of life, behaviour and mood.

    PubMed

    Hallböök, Tove; Lundgren, Johan; Stjernqvist, Karin; Blennow, Gösta; Strömblad, Lars-Göran; Rosén, Ingmar

    2005-10-01

    Vagus nerve stimulation (VNS) is a neurophysiologic treatment for patients with refractory epilepsy. There is growing evidence of additional quality of life (QOL) benefits of VNS. We report the effects of VNS on seizure frequency and severity and how these changes are related to cognitive abilities, QOL, behaviour and mood in 15 children with medically refractory and for surgery not eligible epilepsy. Initially, and after 3 and 9 months of VNS-treatment, 15 children were investigated with Bayley Scales of Infant Development (BSID), Wechsler Preschool and Primary Scale of Intelligence (WPPSI-R), Wechlser Intelligence Scales for Children (WISC-III) depending on the child's level of functioning, a Visual Analogue Scale for validating QOL, Child Behaviour Checklist (CBCL) for quantifying behaviour problems, Dodrill Mood Analogue Scale and Birleson Depression Self-Rating Scale, and the National Hospital Seizure Severity Scale (NHS3). A diary of seizure frequency was collected. Six of 15 children showed a 50% or more reduction in seizure frequency; one of these became seizure-free. Two children had a 25-50% seizure reduction. Two children showed increased seizure frequency. In 13 of 15 children there was an improvement in NHS3. The parents reported shorter duration of seizure and recovery phase. There were no changes in cognitive functioning. Twelve children showed an improvement in QOL. Eleven of these also improved in seizure severity and mood and five also in depressive parameters. This study has shown a good anti-seizure effect of VNS, an improvement in seizure severity and in QOL and a tendency to improvement over time regarding behaviour, mood and depressive parameters. The improvement in seizure severity, QOL, behaviour, mood and depressive parameters was not related to the anti-seizure effect.

  7. Establishment of borehole observation system and high resolution seismic studies in the western part of the main Marmara Fault in the frame of MARSite Project

    NASA Astrophysics Data System (ADS)

    Ozel, A.; Yalcinkaya, E.; Guralp, C. M.; Tunc, S.; Meral Ozel, N.

    2013-12-01

    The main objective of this study is to install a multi-parameter borehole system and surface array as close to the main Marmara Fault (MMF) in the western Marmara Sea as possible, and measure continuously the evolution of the state of the fault zone surrounding the MMF and to detect any anomaly or change which may occur before earthquakes by making use of the data from the arrays already running in the eastern part of the Marmara Sea. The multi-parameter borehole system will be composed of very wide dynamic range and stable borehole (VBB) broad band seismic sensor, and incorporate 3-D strain meter, tilt meter, and temperature and local hydrostatic pressure measuring devices. The borehole seismic station will use the latest update technologies and design ideas to record 'Earth tides' signals to the smallest magnitude -3 events. Bringing face to face the seismograms of microearthquakes recorded by borehole and surface instruments portrays quite different contents. The shorter recording duration and nearly flat frequency spectrum up to the Nyquist frequencies of borehole records are faced with longer recording duration and rapid decay of spectral amplitudes at higher frequencies of a surface seismogram. The main causative of the observed differences are near surface geology effects that mask most of the source related information the seismograms include, and that give rise to scattering, generating longer duration seismograms. In view of these circumstances, studies on microearthquakes employing surface seismograms may bring on misleading results. Particularly, the works on earthquake physics and nucleation process of earthquakes requires elaborate analysis of tiny events. It is obvious from the studies on the nucleation process of the 1999 earthquake that tens of minutes before the major rupture initiate noteworthy microearthquake activity happened. The starting point of the 1999 rupture was a site of swarm activity noticed a few decades prior the main shock. Nowadays, analogous case is probable in western Marmara Sea region, prone to a major event in near future where the seismic activity is prevailing along the impending rupture zone. Deploying a borehole system eastern end of the Ganos fault zone may yield invaluable data to closely inspect and monitor the last stages of the preparation stage of major rupture. Keywords: Borehole seismometer; Ganos fault; microearthquakes; western Marmara

  8. Sentence stress in children with dysarthria and cerebral palsy.

    PubMed

    Kuschmann, Anja; Lowit, Anja

    2018-03-08

    This study aimed to advance our understanding of how children with dysarthria and cerebral palsy (CP) realise sentence stress acoustically, and how well listeners could identify the position of the stressed word within these utterances. Seven children with CP and eight typically developing children participated in the experiment. Stress on target words in two sentence positions was elicited through a picture-based question-answer paradigm. Acoustic parameters of stress [duration, intensity and fundamental frequency (F0)] were measured and compared between stressed and unstressed target words. For the perception experiment, ten listeners were asked to determine the position of the stressed word in the children's productions. Acoustic measures showed that at group level the typically developing children used all three acoustic parameters to mark sentence stress, whereas the children with CP showed changes in duration only. Individual performance variations were evident in both groups. Perceptually, listeners were significantly better at identifying the stressed words in the utterances produced by the typically developing children than those of the children with CP. The results suggest that children with CP can manipulate temporal speech properties to mark stress. This ability to modulate acoustic-prosodic features could be harnessed in intervention to enhance children's functional communication.

  9. Immediate effects of AAF devices on the characteristics of stuttering: a clinical analysis.

    PubMed

    Unger, Julia P; Glück, Christian W; Cholewa, Jürgen

    2012-06-01

    The present study investigated the immediate effects of altered auditory feedback (AAF) and one Inactive Condition (AAF parameters set to 0) on clinical attributes of stuttering during scripted and spontaneous speech. Two commercially available, portable AAF devices were used to create the combined delayed auditory feedback (DAF) and frequency altered feedback (FAF) effects. Thirty adults, who stutter, aged 18-68 years (M=36.5; SD=15.2), participated in this investigation. Each subject produced four sets of 5-min of oral reading, three sets of 5-min monologs as well as 10-min dialogs. These speech samples were analyzed to detect changes in descriptive features of stuttering (frequency, duration, speech/articulatory rate, core behaviors) across the various speech samples and within two SSI-4 (Riley, 2009) based severity ratings. A statistically significant difference was found in the frequency of stuttered syllables (%SS) during both Active Device conditions (p=.000) for all speech samples. The most sizable reductions in %SS occurred within scripted speech. In the analysis of stuttering type, it was found that blocks were reduced significantly (Device A: p=.017; Device B: p=.049). To evaluate the impact on severe and mild stuttering, participants were grouped into two SSI-4 based categories; mild and moderate-severe. During the Inactive Condition those participants within the moderate-severe group (p=.024) showed a statistically significant reduction in overall disfluencies. This result indicates, that active AAF parameters alone may not be the sole cause of a fluency-enhancement when using a technical speech aid. The reader will learn and be able to describe: (1) currently available scientific evidence on the use of altered auditory feedback (AAF) during scripted and spontaneous speech, (2) which characteristics of stuttering are impacted by an AAF device (frequency, duration, core behaviors, speech & articulatory rate, stuttering severity), (3) the effects of an Inactive Condition on people who stutter (PWS) falling into two severity groups, and (4) how the examined participants perceived the use of AAF devices. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. The Accuracy of Eyelid Movement Parameters for Drowsiness Detection

    PubMed Central

    Wilkinson, Vanessa E.; Jackson, Melinda L.; Westlake, Justine; Stevens, Bronwyn; Barnes, Maree; Swann, Philip; Rajaratnam, Shantha M. W.; Howard, Mark E.

    2013-01-01

    Study Objectives: Drowsiness is a major risk factor for motor vehicle and occupational accidents. Real-time objective indicators of drowsiness could potentially identify drowsy individuals with the goal of intervening before an accident occurs. Several ocular measures are promising objective indicators of drowsiness; however, there is a lack of studies evaluating their accuracy for detecting behavioral impairment due to drowsiness in real time. Methods: In this study, eye movement parameters were measured during vigilance tasks following restricted sleep and in a rested state (n = 33 participants) at three testing points (n = 71 data points) to compare ocular measures to a gold standard measure of drowsiness (OSLER). The utility of these parameters for detecting drowsiness-related errors was evaluated using receiver operating characteristic curves (ROC) (adjusted by clustering for participant) and identification of optimal cutoff levels for identifying frequent drowsiness-related errors (4 missed signals in a minute using OSLER). Their accuracy was tested for detecting increasing frequencies of behavioral lapses on a different task (psychomotor vigilance task [PVT]). Results: Ocular variables which measured the average duration of eyelid closure (inter-event duration [IED]) and the ratio of the amplitude to velocity of eyelid closure were reliable indicators of frequent errors (area under the curve for ROC of 0.73 to 0.83, p < 0.05). IED produced a sensitivity and specificity of 71% and 88% for detecting ≥ 3 lapses (PVT) in a minute and 100% and 86% for ≥ 5 lapses. A composite measure of several eye movement characteristics (Johns Drowsiness Scale) provided sensitivities of 77% and 100% for detecting 3 and ≥ 5 lapses in a minute, with specificities of 85% and 83%, respectively. Conclusions: Ocular measures, particularly those measuring the average duration of episodes of eye closure are promising real-time indicators of drowsiness. Citation: Wilkinson VE; Jackson ML; Westlake J; Stevens B; Barnes M; Swann P; Rajaratnam SMW; Howard ME. The accuracy of eyelid movement parameters for drowsiness detection. J Clin Sleep Med 2013;9(12):1315-1324. PMID:24340294

  11. Cellular immunity and lymphokine production during spaceflights

    NASA Technical Reports Server (NTRS)

    Konstantinova, I. V.; Sonnenfeld, G.; Lesniak, A. T.; Shaffar, L.; Mandel, A.; Rykova, M. P.; Antropova, E. N.; Ferrua, B.

    1991-01-01

    Results are presented on changes in cellular immunity and in the production of lymphokine in spacecrews during spaceflights. Measurements were carried out on blood samples collected from 50 cosmonauts before and after spaceflights of different duration, on board Salyut-6, Salyut-7, or Mir. Additional data were obtained from rats flown on board the Cosmos-1667 and Cosmos-1887 biosatellites. The parameters measured included the PHA responsiveness of T lymphocytes, the activity of T-helper cells and of nonspecific T suppressors, the activity of the so-called natural killer lymphocytes, the production of gamma-interferon, and the cell-surface markers. Results showed that the frequency and the extent of changes in the immunologic resistance of subjects depended on the duration of the flight. However, even after the most prolonged (365 days) spaceflight, the changes observed were mostly of a functional character with subsequent rapid return to normal.

  12. Development of independent locomotion in children with a severe visual impairment.

    PubMed

    Hallemans, Ann; Ortibus, Els; Truijen, Steven; Meire, Francoise

    2011-01-01

    Locomotion of children and adults with a visual impairment (ages 1-44, n = 28) was compared to that of age-related individuals with normal vision (n = 60). Participants walked barefoot at preferred speed while their gait was recorded by a Vicon(®) system. Walking speed, heading angle, step frequency, stride length, step width, stance phase duration and double support time were determined. Differences between groups, relationships with age and possible interaction effects were investigated. With increasing age overall improvements in gait parameters are observed. Differences between groups were a slower walking speed, a shorter stride length, a prolonged duration of stance and of double support in the individuals with a visual impairment. These may be considered either as adaptations to balance problems or as strategies to allow to foot to probe the ground. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. The effect of signal duration on the underwater hearing thresholds of two harbor seals (Phoca vitulina) for single tonal signals between 0.2 and 40 kHz.

    PubMed

    Kastelein, Ronald A; Hoek, Lean; Wensveen, Paul J; Terhune, John M; de Jong, Christ A F

    2010-02-01

    The underwater hearing sensitivities of two 2-year-old female harbor seals were quantified in a pool built for acoustic research by using a behavioral psycho-acoustic technique. The animals were trained only to respond when they detected an acoustic signal ("go/no-go" response). Detection thresholds were obtained for pure tone signals (frequencies: 0.2-40 kHz; durations: 0.5-5000 ms, depending on the frequency; 59 frequency-duration combinations). Detection thresholds were quantified by varying the signal amplitude by the 1-up, 1-down staircase method, and were defined as the stimulus levels, resulting in a 50% detection rate. The hearing thresholds of the two seals were similar for all frequencies except for 40 kHz, for which the thresholds differed by, on average, 3.7 dB. There was an inverse relationship between the time constant (tau), derived from an exponential model of temporal integration, and the frequency [log(tau)=2.86-0.94 log(f);tau in ms and f in kHz]. Similarly, the thresholds increased when the pulse was shorter than approximately 780 cycles (independent of the frequency). For pulses shorter than the integration time, the thresholds increased by 9-16 dB per decade reduction in the duration or number of cycles in the pulse. The results of this study suggest that most published hearing thresholds

  14. Lingering Effects of Straw Phonation Exercises on Aerodynamic, Electroglottographic, and Acoustic Parameters.

    PubMed

    Kang, Jing; Xue, Chao; Piotrowski, David; Gong, Ting; Zhang, Yi; Jiang, Jack J

    2018-06-01

    This study aimed to investigate the duration of straw phonation effects using aerodynamic, electroglottographic, and acoustic metrics. Twenty-four participants were recruited to perform both a 5-minute and a 10-minute straw phonation exercise. Upon completion of the exercises, phonation threshold pressure (PTP), mean airflow, contact quotient, fundamental frequency, jitter, shimmer, and noise-to-harmonics ratio were measured over a 20-minute time frame. Parameters were measured before the intervention (baseline), immediately after the intervention (m0), 5 minutes (m5), 10 minutes (m10), 15 minutes (m15), and 20 minutes (m20) after the intervention. PTP significantly decreased immediately after 5 minutes of straw phonation and returned to initial state within 5 minutes. PTP remained decreased over 5 minutes after 10 minutes of straw phonation. Mean airflow increased immediately after both 5 minutes and 10 minutes of straw phonations and remained improved for 20 minutes. No significant changes were obtained for contact quotient and acoustic parameters over the intervention period. The results extended our knowledge of proper clinical application of straw phonation regarding the duration of exercise. This study confirmed that 10 minutes of straw phonation lead to optimal and relatively continuous effects in PTP and mean airflow. Although straw phonation did show lingering effects in aerodynamics, repeated practices were recommended to obtain optimum and therapeutic effects. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  15. A two-parameter design storm for Mediterranean convective rainfall

    NASA Astrophysics Data System (ADS)

    García-Bartual, Rafael; Andrés-Doménech, Ignacio

    2017-05-01

    The following research explores the feasibility of building effective design storms for extreme hydrological regimes, such as the one which characterizes the rainfall regime of the east and south-east of the Iberian Peninsula, without employing intensity-duration-frequency (IDF) curves as a starting point. Nowadays, after decades of functioning hydrological automatic networks, there is an abundance of high-resolution rainfall data with a reasonable statistic representation, which enable the direct research of temporal patterns and inner structures of rainfall events at a given geographic location, with the aim of establishing a statistical synthesis directly based on those observed patterns. The authors propose a temporal design storm defined in analytical terms, through a two-parameter gamma-type function. The two parameters are directly estimated from 73 independent storms identified from rainfall records of high temporal resolution in Valencia (Spain). All the relevant analytical properties derived from that function are developed in order to use this storm in real applications. In particular, in order to assign a probability to the design storm (return period), an auxiliary variable combining maximum intensity and total cumulated rainfall is introduced. As a result, for a given return period, a set of three storms with different duration, depth and peak intensity are defined. The consistency of the results is verified by means of comparison with the classic method of alternating blocks based on an IDF curve, for the above mentioned study case.

  16. Assessment of resting electrocardiogram, P wave dispersion and duration in different genders applying for registration to the School of Physical Education and Sports - results of a single centre Turkish Trial with 2093 healthy subjects.

    PubMed

    Yildiz, Mustafa; Aygin, Dilek; Pazarli, Pinar; Sayan, Ayse; Semiz, Olcay; Kahyaoglu, Osman; Yildiz, Banu S; Hasdemir, Hakan; Akin, Ibrahim; Keser, Nurgul; Altinkaynak, Sevin

    2011-10-01

    The 12-lead electrocardiogram shows a broad range of abnormal patterns in trained athletes. The primary end point of this study was to investigate P wave dispersion, and P wave durations and related factors in different genders applying for registration to the School of Physical Education and Sports. From 2006 to 2009, a total of 2093 students - 1674 boys with a mean age of 19.8 plus or minus 1.9 years and 419 girls with a mean age of 19.1 plus or minus 1.8 years - were included in the study. All 12 leads of the resting electrocardiogram were evaluated for P wave dispersion and electrocardiogram abnormalities. Baseline parameters such as age, body weight, body height, and body mass index, as well as electrocardiogram findings such as P wave maximal duration and P wave dispersion, were significantly higher in boys than in girls. Of all the parameters tested with correlation analysis, only gender (p = 0.03) (r = 0.04), body weight (p < 0.001) (r = 0.07), body height (p = 0.004) (r = 0.06), and body mass index (p = 0.01) (p = 0.05) were correlated with P wave dispersion. The frequencies of all electrocardiogram abnormalities, P wave dispersion, and P wave maximal duration were higher in boys as compared with girls in an unselected student population applying for registration to the School of Physical Education and Sports; in addition, P wave dispersion was correlated with gender, body weight, body height, and body mass index.

  17. Noise frame duration, masking potency and whiteness of temporal noise.

    PubMed

    Kukkonen, Heljä; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antti

    2002-09-01

    Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. Contrast energy thresholds (E(th)) were measured for flicker at 1.25 to 20 Hz in strong, purely temporal (spatially uniform), additive, external noise. The masking power of white external noise, characterized by its spectral density at zero frequency N0, increases with the duration of the noise frame. For short noise frame durations, E(th) increased in direct proportion to N0, keeping the nominal signal-to-noise ratio [SNR = (E(th)/N0)(0.5)] constant at threshold. The masking effect thus increased with the duration of the noise frame and the noise mimicked white noise. When noise frame duration and N0 increased further, the nominal SNR at threshold started to decrease, indicating that noise no longer mimicked white noise. The minimum number of noise frames per flicker cycle needed to mimic white noise decreased with increasing flicker frequency from 8.3 at 1.25 Hz to 1.6 at 20 Hz. The critical high-frequency cutoff of detection-limiting temporal noise in terms of noise frames per signal cycle depends on the temporal frequency of the signal. This is opposite to the situation in the spatial domain and must be taken into consideration when temporal signals are masked with temporal noise.

  18. Analysis of magnitude and duration of floods and droughts in the context of climate change

    NASA Astrophysics Data System (ADS)

    Eshetu Debele, Sisay; Bogdanowicz, Ewa; Strupczewski, Witold

    2016-04-01

    Research and scientific information are key elements of any decision-making process. There is also a strong need for tools to describe and compare in a concise way the regime of hydrological extreme events in the context of presumed climate change. To meet these demands, two complementary methods for estimating high and low-flow frequency characteristics are proposed. Both methods deal with duration and magnitude of extreme events. The first one "flow-duration-frequency" (known as QdF) has already been applied successfully to low-flow analysis, flood flows and rainfall intensity. The second one called "duration-flow-frequency" (DqF) was proposed by Strupczewski et al. in 2010 to flood frequency analysis. The two methods differ in the treatment of flow and duration. In the QdF method the duration (d-consecutive days) is a chosen fixed value and the frequency analysis concerns the annual or seasonal series of mean value of flows exceeded (in the case of floods) or non-exceeded (in the case of droughts) within d-day period. In the second method, DqF, the flows are treated as fixed thresholds and the duration of flows exceeding (floods) and non-exceeding (droughts) these thresholds are a subject of frequency analysis. The comparison of characteristics of floods and droughts in reference period and under future climate conditions for catchments studied within the CHIHE project is presented and a simple way to show the results to non-professionals and decision-makers is proposed. The work was undertaken within the project "Climate Change Impacts on Hydrological Extremes (CHIHE)", which is supported by the Norway-Poland Grants Program administered by the Norwegian Research Council. The observed time series were provided by the Institute of Meteorology and Water Management (IMGW), Poland. Strupczewski, W. G., Kochanek, K., Markiewicz, I., Bogdanowicz, E., Weglarczyk, S., & Singh V. P. (2010). On the Tails of Distributions of Annual Peak Flow. Hydrology Research, 42, 171-192. http://dx.doi.org/10.2166/nh.2011.062

  19. Spectral-Temporal Evolution of Low-Frequency Pulsations in the Microwave Radiation of Solar Flares

    NASA Astrophysics Data System (ADS)

    Zaitsev, V. V.; Kislyakov, A. G.; Urpo, S.; Stepanov, A. V.; Shkelev, E. I.

    2003-10-01

    Low-frequency pulsations of 22 and 37 GHz microwave radiation detected during solar flares are analyzed. Several microwave bursts observed at the Metsähovi Radio Observatory are studied with time resolutions of 100 and 50 ms. A fast Fourier transformation with a sliding window and the Wigner-Ville method are used to obtain frequency-time diagrams for the low-frequency pulsations, which are interpreted as natural oscillations of coronal magnetic loops; the dynamical spectra of the pulsations are synthesized for the first time. Three types of low-frequency fluctuations modulating the flare microwave radiation can be distinguished in the observations. First, there are fast and slow magneto-acoustic oscillations with periods of 0.5 0.8 s and 200 280 s, respectively. The fast magneto-acoustic oscillations appear as trains of narrow-band signals with durations of 100 200 s, a positive frequency drift dν/dt=0.25 MHz/min, and frequency splitting δν=0.01 0.05 Hz. Second, there are natural oscillations of the coronal magnetic loops as equivalent electrical circuits. These oscillations have periods of 0.5 10 s and positive or negative frequency drift rates dν/dt=8×10-3 Hz/min or dν/dt=-1.3×10-2 Hz/min, depending on the phase of the radio outburst. Third, there are modulations of the microwave radiation by short periodic pulses with a period of 20 s. The dynamical spectra of the low-frequency pulsations supply important information about the parameters of the magnetic loops: the ratio of the loop radius to its length r/L≈0.1, the plasma parameter β≈10-3, the ratio of the plasma densities outside and inside the loop ρe/ρi≈10-2, and the electrical current flowing along the loop I≈1012 A.

  20. Adaptive echolocation behavior in bats for the analysis of auditory scenes

    PubMed Central

    Chiu, Chen; Xian, Wei; Moss, Cynthia F.

    2009-01-01

    Summary Echolocating bats emit sonar pulses and listen to returning echoes to probe their surroundings. Bats adapt their echolocation call design to cope with dynamic changes in the acoustic environment, including habitat change or the presence of nearby conspecifics/heterospecifics. Seven pairs of big brown bats, Eptesicus fuscus, were tested in this study to examine how they adjusted their echolocation calls when flying and competing with a conspecific for food. Results showed that differences in five call parameters, start/end frequencies, duration, bandwidth and sweep rate, significantly increased in the two-bat condition compared with the baseline data. In addition, the magnitude of spectral separation of calls was negatively correlated with the baseline call design differences in individual bats. Bats with small baseline call frequency differences showed larger increases in call frequency separation when paired than those with large baseline call frequency differences, suggesting that bats actively change their sonar call structure if pre-existing differences in call design are small. Call design adjustments were also influenced by physical spacing between two bats. Calls of paired bats exhibited the largest design separations when inter-bat distance was shorter than 0.5 m, and the separation decreased as the spacing increased. All individuals modified at least one baseline call parameter in response to the presence of another conspecific. We propose that dissimilarity between the time–frequency features of sonar calls produced by different bats aids each individual in segregating echoes of its own sonar vocalizations from the acoustic signals of neighboring bats. PMID:19376960

  1. The edge of awareness: Mask spatial density, but not color, determines optimal temporal frequency for continuous flash suppression.

    PubMed

    Drewes, Jan; Zhu, Weina; Melcher, David

    2018-01-01

    The study of how visual processing functions in the absence of visual awareness has become a major research interest in the vision-science community. One of the main sources of evidence that stimuli that do not reach conscious awareness-and are thus "invisible"-are still processed to some degree by the visual system comes from studies using continuous flash suppression (CFS). Why and how CFS works may provide more general insight into how stimuli access awareness. As spatial and temporal properties of stimuli are major determinants of visual perception, we hypothesized that these properties of the CFS masks would be of significant importance to the achieved suppression depth. In previous studies however, the spatial and temporal properties of the masks themselves have received little study, and masking parameters vary widely across studies, making a metacomparison difficult. To investigate the factors that determine the effectiveness of CFS, we varied both the temporal frequency and the spatial density of Mondrian-style masks. We consistently found the longest suppression duration for a mask temporal frequency of around 6 Hz. In trials using masks with reduced spatial density, suppression was weaker and frequency tuning was less precise. In contrast, removing color reduced mask effectiveness but did not change the pattern of suppression strength as a function of frequency. Overall, this pattern of results stresses the importance of CFS mask parameters and is consistent with the idea that CFS works by disrupting the spatiotemporal mechanisms that underlie conscious access to visual input.

  2. Modal identification of structures by a novel approach based on FDD-wavelet method

    NASA Astrophysics Data System (ADS)

    Tarinejad, Reza; Damadipour, Majid

    2014-02-01

    An important application of system identification in structural dynamics is the determination of natural frequencies, mode shapes and damping ratios during operation which can then be used for calibrating numerical models. In this paper, the combination of two advanced methods of Operational Modal Analysis (OMA) called Frequency Domain Decomposition (FDD) and Continuous Wavelet Transform (CWT) based on novel cyclic averaging of correlation functions (CACF) technique are used for identification of dynamic properties. By using this technique, the autocorrelation of averaged correlation functions is used instead of original signals. Integration of FDD and CWT methods is used to overcome their deficiency and take advantage of the unique capabilities of these methods. The FDD method is able to accurately estimate the natural frequencies and mode shapes of structures in the frequency domain. On the other hand, the CWT method is in the time-frequency domain for decomposition of a signal at different frequencies and determines the damping coefficients. In this paper, a new formulation applied to the wavelet transform of the averaged correlation function of an ambient response is proposed. This application causes to accurate estimation of damping ratios from weak (noise) or strong (earthquake) vibrations and long or short duration record. For this purpose, the modified Morlet wavelet having two free parameters is used. The optimum values of these two parameters are obtained by employing a technique which minimizes the entropy of the wavelet coefficients matrix. The capabilities of the novel FDD-Wavelet method in the system identification of various dynamic systems with regular or irregular distribution of mass and stiffness are illustrated. This combined approach is superior to classic methods and yields results that agree well with the exact solutions of the numerical models.

  3. [Modulating effect of weak combined magnetic fields on duration of mealworm beetle Tenebrio molitor metamorphosis stage].

    PubMed

    Novikov, V V; Sheĭman, I M; Iablokova, E V; Fesenko, E E

    2014-01-01

    It is shown that an exposure of pupae of the mealworm beetle Tenebrio molitor to the combined static (42 μT) and very weak alternating (250 nT) magnetic fields exerts different influence, depending on the frequency of the alternating magnetic field, on duration of metamorphosis processes in these insects. For instance, an exposure of pupae to weak combined magnetic fields, adjusted to the frequency of ion cyclotron resonance for glutaminic acid (4,4 Hz), stimulates metamorphosis process--a transitional stage from pupae to imago lasts shorter. An inhibiting effect was observed when adjusted to the frequency of ion cyclotron resonance for Ca2 (32,2 Hz). At some frequencies this effect is not seen. For instance, an exposure at a frequency of ion cyclotron resonance for K+ (16,5 Hz) exerts no noticeable effect on the duration of the pupal metamorphosis stage.

  4. Thought suppression across time: Change in frequency and duration of thought recurrence.

    PubMed

    Lambert, Ann E; Hu, Yueqin; Magee, Joshua C; Beadel, Jessica R; Teachman, Bethany A

    2014-01-01

    Some studies have found that trying to suppress thoughts increases their long-term recurrence, a phenomenon associated with psychopathology, particularly obsessive-compulsive disorder. However, effect sizes in thought suppression studies have often been small and inconsistent. The present study sought to improve thought suppression conceptualization and measurement by examining two distinct dimensions of thought recurrence - frequency and duration of a thought's return - and how they evolve over time. After a thought focus period, 100 adults were assigned to either suppress or monitor the recurrence of an unpleasant thought for 4 min. Then, during a second four-minute period, all participants were asked to monitor the thought's recurrence. Hierarchical linear modeling indicated that thought frequency declined across time and the rate of decline slowed as time went on. Initially, the extent of thought duration remained short and stable for those asked to suppress, and increased linearly over time for those asked to monitor. Later, this pattern reversed. Duration increased linearly for those initially asked to suppress but was short and stable for those who initially monitored. Accounting for change over time and means of measuring recurrence (frequency vs. duration) may help elucidate past mixed findings, and improve thought suppression research methodology.

  5. Experimental Assessment of the Effects of Temperature and Food Availability on Particle Mixing by the Bivalve Abra alba Using New Image Analysis Techniques

    PubMed Central

    Bernard, Guillaume; Duchêne, Jean-Claude; Romero-Ramirez, Alicia; Lecroart, Pascal; Maire, Olivier; Ciutat, Aurélie; Deflandre, Bruno; Grémare, Antoine

    2016-01-01

    The effects of temperature and food addition on particle mixing in the deposit-feeding bivalve Abra alba were assessed using an experimental approach allowing for the tracking of individual fluorescent particle (luminophore) displacements. This allowed for the computations of vertical profiles of a set of parameters describing particle mixing. The frequency of luminophore displacements (jumps) was assessed through the measurement of both waiting times (i.e., the time lapses between two consecutive jumps of the same luminophore) and normalized numbers of jumps (i.e., the numbers of jumps detected in a given area divided by the number of luminophores in this area). Jump characteristics included the direction, duration and length of each jump. Particle tracking biodiffusion coefficients (Db) were also computed. Data originated from 32 experiments carried out under 4 combinations of 2 temperature (Te) and 2 food addition (Fo) levels. For each of these treatments, parameters were computed for 5 experimental durations (Ed). The effects of Se, Fo and Ed were assessed using PERmutational Multivariate ANalyses Of VAriance (PERMANOVAs) carried out on vertical depth profiles of each particle mixing parameter. Inversed waiting times significantly decreased with Ed whereas the normalized number of jumps did not, thereby suggesting that it constitutes a better proxy of jump frequency when assessing particle mixing based on the measure of individual particle displacements. Particle mixing was low during autumn temperature experiments and not affected by Fo, which was attributed to the dominant effect of low temperature. Conversely, particle mixing was high during summer temperature experiments and transitory inhibited by food addition. This last result is coherent with the functional responses (both in terms of activity and particle mixing) already measured for individual of the closely related clam A. ovata originating from temperate populations. It also partly resulted from a transitory switch between deposit- and suspension-feeding caused by the high concentration of suspended particulate organic matter immediately following food addition. PMID:27115148

  6. Comparing performances of logistic regression and neural networks for predicting melatonin excretion patterns in the rat exposed to ELF magnetic fields.

    PubMed

    Jahandideh, Samad; Abdolmaleki, Parviz; Movahedi, Mohammad Mehdi

    2010-02-01

    Various studies have been reported on the bioeffects of magnetic field exposure; however, no consensus or guideline is available for experimental designs relating to exposure conditions as yet. In this study, logistic regression (LR) and artificial neural networks (ANNs) were used in order to analyze and predict the melatonin excretion patterns in the rat exposed to extremely low frequency magnetic fields (ELF-MF). Subsequently, on a database containing 33 experiments, performances of LR and ANNs were compared through resubstitution and jackknife tests. Predictor variables were more effective parameters and included frequency, polarization, exposure duration, and strength of magnetic fields. Also, five performance measures including accuracy, sensitivity, specificity, Matthew's Correlation Coefficient (MCC) and normalized percentage, better than random (S) were used to evaluate the performance of models. The LR as a conventional model obtained poor prediction performance. Nonetheless, LR distinguished the duration of magnetic fields as a statistically significant parameter. Also, horizontal polarization of magnetic fields with the highest logit coefficient (or parameter estimate) with negative sign was found to be the strongest indicator for experimental designs relating to exposure conditions. This means that each experiment with horizontal polarization of magnetic fields has a higher probability to result in "not changed melatonin level" pattern. On the other hand, ANNs, a more powerful model which has not been introduced in predicting melatonin excretion patterns in the rat exposed to ELF-MF, showed high performance measure values and higher reliability, especially obtaining 0.55 value of MCC through jackknife tests. Obtained results showed that such predictor models are promising and may play a useful role in defining guidelines for experimental designs relating to exposure conditions. In conclusion, analysis of the bioelectromagnetic data could result in finding a relationship between electromagnetic fields and different biological processes. (c) 2009 Wiley-Liss, Inc.

  7. Experimental Assessment of the Effects of Temperature and Food Availability on Particle Mixing by the Bivalve Abra alba Using New Image Analysis Techniques.

    PubMed

    Bernard, Guillaume; Duchêne, Jean-Claude; Romero-Ramirez, Alicia; Lecroart, Pascal; Maire, Olivier; Ciutat, Aurélie; Deflandre, Bruno; Grémare, Antoine

    2016-01-01

    The effects of temperature and food addition on particle mixing in the deposit-feeding bivalve Abra alba were assessed using an experimental approach allowing for the tracking of individual fluorescent particle (luminophore) displacements. This allowed for the computations of vertical profiles of a set of parameters describing particle mixing. The frequency of luminophore displacements (jumps) was assessed through the measurement of both waiting times (i.e., the time lapses between two consecutive jumps of the same luminophore) and normalized numbers of jumps (i.e., the numbers of jumps detected in a given area divided by the number of luminophores in this area). Jump characteristics included the direction, duration and length of each jump. Particle tracking biodiffusion coefficients (Db) were also computed. Data originated from 32 experiments carried out under 4 combinations of 2 temperature (Te) and 2 food addition (Fo) levels. For each of these treatments, parameters were computed for 5 experimental durations (Ed). The effects of Se, Fo and Ed were assessed using PERmutational Multivariate ANalyses Of VAriance (PERMANOVAs) carried out on vertical depth profiles of each particle mixing parameter. Inversed waiting times significantly decreased with Ed whereas the normalized number of jumps did not, thereby suggesting that it constitutes a better proxy of jump frequency when assessing particle mixing based on the measure of individual particle displacements. Particle mixing was low during autumn temperature experiments and not affected by Fo, which was attributed to the dominant effect of low temperature. Conversely, particle mixing was high during summer temperature experiments and transitory inhibited by food addition. This last result is coherent with the functional responses (both in terms of activity and particle mixing) already measured for individual of the closely related clam A. ovata originating from temperate populations. It also partly resulted from a transitory switch between deposit- and suspension-feeding caused by the high concentration of suspended particulate organic matter immediately following food addition.

  8. Nanosecond pulsed laser welding of high carbon steels

    NASA Astrophysics Data System (ADS)

    Ascari, Alessandro; Fortunato, Alessandro

    2014-03-01

    The present paper deals with the possibility to exploit low-cost, near infra-red, nanosecond pulsed laser sources in welding of high carbon content thin sheets. The exploitation of these very common sources allows to achieve sound weld beads with a good depth-to-width ratio and very small heat affected zones when the proper process parameters are involved. In particular the role of pulse frequency, pulse duration, peak power and welding speed on the characteristics of the weld beads is studied and the advantage of the application of short-pulse laser sources over traditional long-pulse or continuous wave one is assessed.

  9. Terminal navigation analysis for the 1980 comet Encke slow flyby mission

    NASA Technical Reports Server (NTRS)

    Jacobson, R. A.; Mcdanell, J. P.; Rinker, G. C.

    1973-01-01

    The initial results of a terminal navigation analysis for the proposed 1980 solar electric slow flyby mission to the comet Encke are presented. The navigation technique employs onboard optical measurements with the scientific television camera, groundbased observations of the spacecraft and comet, and groundbased orbit determination and thrust vector update computation. The knowledge and delivery accuracies of the spacecraft are evaluated as a function of the important parameters affecting the terminal navigation. These include optical measurement accuracy, thruster noise level, duration of the planned terminal coast period, comet ephemeris uncertainty, guidance initiation time, guidance update frequency, and optical data rate.

  10. The precision of locomotor odometry in humans.

    PubMed

    Durgin, Frank H; Akagi, Mikio; Gallistel, Charles R; Haiken, Woody

    2009-03-01

    Two experiments measured the human ability to reproduce locomotor distances of 4.6-100 m without visual feedback and compared distance production with time production. Subjects were not permitted to count steps. It was found that the precision of human odometry follows Weber's law that variability is proportional to distance. The coefficients of variation for distance production were much lower than those measured for time production for similar durations. Gait parameters recorded during the task (average step length and step frequency) were found to be even less variable suggesting that step integration could be the basis for non-visual human odometry.

  11. Integrated Multidisciplinary Fault Observation System in the western part of the main Marmara Fault in the frame of an EU-FP7 project, titled as MARSITE

    NASA Astrophysics Data System (ADS)

    Ozel, Oguz; Guralp, Cansun; Tunc, Suleyman; Yalcinkaya, Esref; Meral Ozel, Nurcan

    2015-04-01

    The main objective of this study is to install a multi-parameter borehole system and surface array consisting of eight broadband sensors as close to the main Marmara Fault (MMF) in the western Marmara Sea as possible, and measure continuously the evolution of the state of the fault zone surrounding the MMF and to detect any anomaly or change which may occur before earthquakes by making use of the data from these arrays. The multi-parameter borehole system is composed of very wide dynamic range and stable borehole (VBB) broad band seismic sensor, and incorporate 3-D strain meter, tilt meter, and temperature and local hydrostatic pressure measuring devices. All these sensors are installed in 146m-deep borehole. All the sensor outputs are digitized; total of 11*24 bit-channels and 6*20 bit-channels. Real-time data transmission to the main server of the Marsite Project at Kandilli Observatory in Istanbul is accomplished. The multi-parameter borehole seismic station uses the latest update technologies and design ideas to record "Earth tides" signals to the smallest magnitude -3 events, as the innovative part of the Marsite Project. Bringing face to face the seismograms of microearthquakes recorded by borehole and surface instruments portrays quite different contents. The shorter recording duration and nearly flat frequency spectrum up to the Nyquist frequencies of borehole records are faced with longer recording duration and rapid decay of spectral amplitudes at higher frequencies of a surface seismogram. The main causative of the observed differences are near surface geology effects that mask most of the source related information the seismograms include, and that give rise to scattering, generating longer duration seismograms. In view of these circumstances, studies on microearthquakes employing surface seismograms may bring on misleading results. Particularly, the works on earthquake physics and nucleation process of earthquakes requires elaborate analysis of tiny events. It is obvious from the studies on the nucleation process of the 1999 earthquake that tens of minutes before the major rupture initiate noteworthy microearthquake activity happened. The starting point of the 1999 rupture was a site of swarm activity noticed a few decades prior the main shock. Nowadays, analogous case is probable in western Marmara Sea region, prone to a major event in near future where the seismic activity is prevailing along the impending rupture zone. Having deployed a borehole system at the eastern end of the Ganos fault zone will yield invaluable data to closely inspect and monitor the last stages of the preparation stage of major rupture.

  12. Lexical frequency and voice assimilation in complex words in Dutch

    NASA Astrophysics Data System (ADS)

    Ernestus, Mirjam; Lahey, Mybeth; Verhees, Femke; Baayen, Harald

    2004-05-01

    Words with higher token frequencies tend to have more reduced acoustic realizations than lower frequency words (e.g., Hay, 2000; Bybee, 2001; Jurafsky et al., 2001). This study documents frequency effects for regressive voice assimilation (obstruents are voiced before voiced plosives) in Dutch morphologically complex words in the subcorpus of read-aloud novels in the corpus of spoken Dutch (Oostdijk et al., 2002). As expected, the initial obstruent of the cluster tends to be absent more often as lexical frequency increases. More importantly, as frequency increases, the duration of vocal-fold vibration in the cluster decreases, and the duration of the bursts in the cluster increases, after partialing out cluster duration. This suggests that there is less voicing for higher-frequency words. In fact, phonetic transcriptions show regressive voice assimilation for only half of the words and progressive voice assimilation for one third. Interestingly, the progressive voice assimilation observed for higher-frequency complex words renders these complex words more similar to monomorphemic words: Dutch monomorphemic words typically contain voiceless obstruent clusters (Zonneveld, 1983). Such high-frequency complex words may therefore be less easily parsed into their constituent morphemes (cf. Hay, 2000), favoring whole word lexical access (Bertram et al., 2000).

  13. The effect of beat frequency on eye movements during free viewing.

    PubMed

    Maróti, Emese; Knakker, Balázs; Vidnyánszky, Zoltán; Weiss, Béla

    2017-02-01

    External periodic stimuli entrain brain oscillations and affect perception and attention. It has been shown that background music can change oculomotor behavior and facilitate detection of visual objects occurring on the musical beat. However, whether musical beats in different tempi modulate information sampling differently during natural viewing remains to be explored. Here we addressed this question by investigating how listening to naturalistic drum grooves in two different tempi affects eye movements of participants viewing natural scenes on a computer screen. We found that the beat frequency of the drum grooves modulated the rate of eye movements: fixation durations were increased at the lower beat frequency (1.7Hz) as compared to the higher beat frequency (2.4Hz) and no music conditions. Correspondingly, estimated visual sampling frequency decreased as fixation durations increased with lower beat frequency. These results imply that slow musical beats can retard sampling of visual information during natural viewing by increasing fixation durations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Comparing stochastic point-source and finite-source ground-motion simulations: SMSIM and EXSIM

    USGS Publications Warehouse

    Boore, D.M.

    2009-01-01

    Comparisons of ground motions from two widely used point-source and finite-source ground-motion simulation programs (SMSIM and EXSIM) show that the following simple modifications in EXSIM will produce agreement in the motions from a small earthquake at a large distance for the two programs: (1) base the scaling of high frequencies on the integral of the squared Fourier acceleration spectrum; (2) do not truncate the time series from each subfault; (3) use the inverse of the subfault corner frequency for the duration of motions from each subfault; and (4) use a filter function to boost spectral amplitudes at frequencies near and less than the subfault corner frequencies. In addition, for SMSIM an effective distance is defined that accounts for geometrical spreading and anelastic attenuation from various parts of a finite fault. With these modifications, the Fourier and response spectra from SMSIM and EXSIM are similar to one another, even close to a large earthquake (M 7), when the motions are averaged over a random distribution of hypocenters. The modifications to EXSIM remove most of the differences in the Fourier spectra from simulations using pulsing and static subfaults; they also essentially eliminate any dependence of the EXSIM simulations on the number of subfaults. Simulations with the revised programs suggest that the results of Atkinson and Boore (2006), computed using an average stress parameter of 140 bars and the original version of EXSIM, are consistent with the revised EXSIM with a stress parameter near 250 bars.

  15. Effect of the loss of auditory feedback on segmental parameters of vowels of postlingually deafened speakers.

    PubMed

    Schenk, Barbara S; Baumgartner, Wolf Dieter; Hamzavi, Jafar Sasan

    2003-12-01

    The most obvious and best documented changes in speech of postlingually deafened speakers are the rate, fundamental frequency, and volume (energy). These changes are due to the lack of auditory feedback. But auditory feedback affects not only the suprasegmental parameters of speech. The aim of this study was to determine the change at the segmental level of speech in terms of vowel formants. Twenty-three postlingually deafened and 18 normally hearing speakers were recorded reading a German text. The frequencies of the first and second formants and the vowel spaces of selected vowels in word-in-context condition were compared. All first formant frequencies (F1) of the postlingually deafened speakers were significantly different from those of the normally hearing people. The values of F1 were higher for the vowels /e/ (418+/-61 Hz compared with 359+/-52 Hz, P=0.006) and /o/ (459+/-58 compared with 390+/-45 Hz, P=0.0003) and lower for /a/ (765+/-115 Hz compared with 851+/-146 Hz, P=0.038). The second formant frequency (F2) only showed a significant increase for the vowel/e/(2016+/-347 Hz compared with 2279+/-250 Hz, P=0.012). The postlingually deafened people were divided into two subgroups according to duration of deafness (shorter/longer than 10 years of deafness). There was no significant difference in formant changes between the two groups. Our report demonstrated an effect of auditory feedback also on segmental features of speech of postlingually deafened people.

  16. Estimates of Flow Duration, Mean Flow, and Peak-Discharge Frequency Values for Kansas Stream Locations

    USGS Publications Warehouse

    Perry, Charles A.; Wolock, David M.; Artman, Joshua C.

    2004-01-01

    Streamflow statistics of flow duration and peak-discharge frequency were estimated for 4,771 individual locations on streams listed on the 1999 Kansas Surface Water Register. These statistics included the flow-duration values of 90, 75, 50, 25, and 10 percent, as well as the mean flow value. Peak-discharge frequency values were estimated for the 2-, 5-, 10-, 25-, 50-, and 100-year floods. Least-squares multiple regression techniques were used, along with Tobit analyses, to develop equations for estimating flow-duration values of 90, 75, 50, 25, and 10 percent and the mean flow for uncontrolled flow stream locations. The contributing-drainage areas of 149 U.S. Geological Survey streamflow-gaging stations in Kansas and parts of surrounding States that had flow uncontrolled by Federal reservoirs and used in the regression analyses ranged from 2.06 to 12,004 square miles. Logarithmic transformations of climatic and basin data were performed to yield the best linear relation for developing equations to compute flow durations and mean flow. In the regression analyses, the significant climatic and basin characteristics, in order of importance, were contributing-drainage area, mean annual precipitation, mean basin permeability, and mean basin slope. The analyses yielded a model standard error of prediction range of 0.43 logarithmic units for the 90-percent duration analysis to 0.15 logarithmic units for the 10-percent duration analysis. The model standard error of prediction was 0.14 logarithmic units for the mean flow. Regression equations used to estimate peak-discharge frequency values were obtained from a previous report, and estimates for the 2-, 5-, 10-, 25-, 50-, and 100-year floods were determined for this report. The regression equations and an interpolation procedure were used to compute flow durations, mean flow, and estimates of peak-discharge frequency for locations along uncontrolled flow streams on the 1999 Kansas Surface Water Register. Flow durations, mean flow, and peak-discharge frequency values determined at available gaging stations were used to interpolate the regression-estimated flows for the stream locations where available. Streamflow statistics for locations that had uncontrolled flow were interpolated using data from gaging stations weighted according to the drainage area and the bias between the regression-estimated and gaged flow information. On controlled reaches of Kansas streams, the streamflow statistics were interpolated between gaging stations using only gaged data weighted by drainage area.

  17. Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

    NASA Technical Reports Server (NTRS)

    Spiljak, M.; Petric, A. Domanjko; Wilberg, M.; Olsen, L. H.; Stepancic, A.; Schlegel, T. T.; Starc, V.

    2011-01-01

    Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

  18. The Effects of Exposure to Low Frequency Electromagnetic Fields on Male Fertility.

    PubMed

    Darbandi, Mahsa; Darbandi, Sara; Agarwal, Ashok; Henkle, Ralf; Sadeghi, Mohammad Reza

    2017-06-23

    Context • People are increasingly exposed to low frequency (LF) electromagnetic fields (EMFs), mainly from electricity distribution networks and electronic devices. Critics of this widespread exposure believe that it can have detrimental effects on the human body. On the other hand, many in vivo and in vitro studies have claimed that low frequency electromagnetic therapy can function as a form of alternative medicine and that therapists can treat disease by applying electromagnetic radiation or pulsed EMFs to the body or cells. It is not yet entirely clear, however, whether LF-EMF is beneficial or harmful. Objectives • This study aimed to examine the effects of LF-EMFs on men's reproductive functions, according to the types of waveform and the frequency and duration of exposure. Design • The study reviewed all available research, both human and animal, on the effects of LF-EMFs on male reproductive functions, covering the literature from January 1978 to June 2016. The documents were obtained from PubMed, Science Direct, and Google Scholar, and any article that was irrelevant or a duplicate was excluded. A total of 61 articles were found, and 27 articles were reviewed. Setting • This project was performed at the Avicenna Research Center (Tehran, Iran). Participants • Literature included human and animal studies conducted on rabbits, mice, rats, and boars. Intervention • Among these studies, any article that was irrelevant, a duplicate, or published with duplicate data was excluded. At the end, 27 articles were checked. Outcome Measures • Outcome measures included testing related to reproductive organ weights, reproductive endocrinal hormones, fetal development, and spermatogenesis as well as sperm motility, morphology, and vitality. Results • The reviewed studies provided contradictory results that were highly dependent on the exposure parameters, such as the shape and frequency of wave, intensity, duration, and timing of the exposure. Conclusions • LF-EMF at 15 Hz with a peak intensity of 8 Gauss, with a square waveform of 50 Hz frequency and a duration of a few hours or less can have a positive effect on sperm quality, motility, and fertility. Exposures at other frequencies either had no effects on the sperm's performance and quality or held biological hazard for cells. It appears that there is still little understanding of how EMF affects cellular functions. Therefore, more standardized and controlled studies should be carried out to understand the effects of EMF on the body.

  19. Activity in the chronically critically ill.

    PubMed

    Winkelman, Chris; Higgins, Patricia A; Chen, Yea-Jyh Kathy

    2005-01-01

    Although therapeutic activity prevents functional decline and reduces mortality, little is known about typical levels of activity among intensive care unit (ICU) patients. This report of a preliminary study describes typical therapeutic activity and compares the use of two measures of activity in a small sample of chronically critically ill adults. Type, frequency, and duration of therapeutic activity were measured simultaneously with direct observation and actigraphy. The only consistent activity documented was turning (frequency: 3 turns/8 hours; duration: mean average of 11 minutes). Analysis demonstrated acceptable agreement between the two measures of activity for both frequency and duration of therapeutic but not for type of activity. Congruence between measures for duration of activity was also supported. This study provides information for investigators and practitioners who are interested in measuring or implementing therapeutic activity in selected critically ill adults.

  20. Activity in the Chronically Critically III

    PubMed Central

    Winkelman, Chris; Higgins, Patricia A.; Kathy Chen, Yea-Jyh

    2006-01-01

    Although therapeutic activity prevents functional decline and reduces mortality, little is known about typical levels of activity among intensive care unit (ICU) patients. This report of a preliminary study describes typical therapeutic activity and compares the use of two measures of activity in a small sample of chronically critically ill adults. Type, frequency, and duration of therapeutic activity were measured simultaneously with direct observation and actigraphy. The only consistent activity documented was turning (frequency: 3 turns/8 hours; duration: mean average of 11 minutes). Analysis demonstrated acceptable agreement between the two measures of activity for both frequency and duration of therapeutic but not for type of activity. Congruence between measures for duration of activity was also supported. This study provides information for investigators and practitioners who are interested in measuring or implementing therapeutic activity in selected critically ill adults. PMID:16327517

  1. High-frequency seismic energy radiation from the 2003 Miyagi-Oki, JAPAN, earthquake (M7.0) as revealed from an envelope inversion analysis

    NASA Astrophysics Data System (ADS)

    Nakahara, H.

    2003-12-01

    The 2003 Miyagi-Oki earthquake (M 7.0) took place on May 26, 2003 in the subducting Pacific plate beneath northeastern Japan. The focal depth is around 70km. The focal mechanism is reverse type on a fault plane dipping to the west with a high angle. There was no fatality, fortunately. However, this earthquake caused more than 100 injures, 2000 collapsed houses, and so on. To the south of this focal area by about 50km, an interplate earthquake of M7.5, the Miyagi-Ken-Oki earthquake, is expected to occur in the near future. So the relation between this earthquake and the expected Miyagi-Ken-Oki earthquake attracts public attention. Seismic-energy distribution on earthquake fault planes estimated by envelope inversion analyses can contribute to better understanding of the earthquake source process. For moderate to large earthquakes, seismic energy in frequencies higher than 1 Hz is sometimes much larger than a level expected from the omega-squared model with source parameters estimated by lower-frequency analyses. Therefore, an accurate estimation of seismic energy in such high frequencies has significant importance on estimation of dynamic source parameters such as the seismic energy or the apparent stress. In this study, we execute an envelope inversion analysis based on the method by Nakahara et al. (1998) and clarify the spatial distribution of high-frequency seismic energy radiation on the fault plane of this earthquake. We use three-component sum of mean squared velocity seismograms multiplied by a density of earth medium, which is called envelopes here, for the envelope inversion analysis. Four frequency bands of 1-2, 2-4, 4-8, and 8-16 Hz are adopted. We use envelopes in the time window from the onset of S waves to the lapse time of 51.2 sec. Green functions of envelopes representing the energy propagation process through a scattering medium are calculated based on the radiative transfer theory, which are characterized by parameters of scattering attenuation and intrinsic absorption. We use the values obtained for the northeastern Japan (Sakurai, 1995). We assume the fault plane as follows: strike=193,a, dip=69,a, rake=87,a, length=30km, width=25km with referrence to a waveform inversion analysis in low-frequencies (e.g. Yagi, 2003). We divide this fault plane into 25 subfaults, each of which is a 5km x 5km square. Rupture velocity is assumed to be constant. Seismic energy is radiated from a point source as soon as the rupture front passes the center of each subfault. Time function of energy radiation is assumed as a box-car function. The amount of seismic energy from all the subfaults and site amplification factors for all the stations are estimated by the envelope inversion method. Rupture velocity and the duration time of a box-car function should be estimated by a grid search. Theoretical envelopes calculated with best-fit parameters generally fit to observed ones. The rupture velocity and duration time were estimated as 3.8 km/s and 1.6 sec, respectively. The high-frequency seismic energy was found to be radiated mainly from two spots on the fault plane: The first one is around the initial rupture point and the second is the northern part of the fault plane. These two spots correspond to observed two peaks on envelopes. Amount of seismic energy increases with increasing frequency in the 1-16Hz band, which contradicts an expectation from the omega-squared model. Therefore, stronger radiation of higher-frequency seismic energy is a prominent character of this earthquake. Acknowledgements: We used strong-motion seismograms recorded by the K-NET and KiK-net of NIED, JAPAN.

  2. Quantified outdoor micro-activity data for children aged 7-12-years old.

    PubMed

    Beamer, Paloma I; Luik, Catherine E; Canales, Robert A; Leckie, James O

    2012-01-01

    Estimation of aggregate exposure and risk requires detailed information regarding dermal contact and mouthing activity. We analyzed micro-level activity time series (MLATS) of children aged 7-12 years to quantify these contact behaviors and evaluate differences by age and gender. In all, 18 children, aged 7-12 years, were videotaped while playing outdoors. Video footage was transcribed via Virtual Timing Device (VTD) software. We calculated the hand and mouth contact frequency, hourly duration and median duration of contact with 16 object categories. Median mouthing frequencies were 12.6 events/h and 2.6 events/h for hands and non-dietary objects, respectively. Median hourly mouthing duration was 0.4 min/h and 0.1 min/h with hands and objects. Median mouthing contact duration was 1 s and 1.5 s with hands and objects, respectively. The median object contact frequency for both the hands combined was 537.3 events/h with an hourly contact duration of 81.8 min/h and a median contact duration of 3 s. There were no significant differences in the mouthing activity between genders or age groups. Female children had longer and more frequent hand contacts with several surface types. Age was negatively correlated with hand contacts of floor and wood surfaces. Contact frequencies in this study are higher than current regulatory recommendations for this age group.

  3. Variability in Word Duration as a Function of Probability, Speech Style, and Prosody

    PubMed Central

    Baker, Rachel E.; Bradlow, Ann R.

    2010-01-01

    This article examines how probability (lexical frequency and previous mention), speech style, and prosody affect word duration, and how these factors interact. Participants read controlled materials in clear and plain speech styles. As expected, more probable words (higher frequencies and second mentions) were significantly shorter than less probable words, and words in plain speech were significantly shorter than those in clear speech. Interestingly, we found second mention reduction effects in both clear and plain speech, indicating that while clear speech is hyper-articulated, this hyper-articulation does not override probabilistic effects on duration. We also found an interaction between mention and frequency, but only in plain speech. High frequency words allowed more second mention reduction than low frequency words in plain speech, revealing a tendency to hypo-articulate as much as possible when all factors support it. Finally, we found that first mentions were more likely to be accented than second mentions. However, when these differences in accent likelihood were controlled, a significant second mention reduction effect remained. This supports the concept of a direct link between probability and duration, rather than a relationship solely mediated by prosodic prominence. PMID:20121039

  4. Research of the Effect Caused by Terrestrial Power Sources on the Near-Earth Space above China based on DEMETER Satellite Data

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Wu, J.; Ma, Q.

    2017-12-01

    The environmental effect on the ionosphere caused by man-made power line emission (PLE) and power line harmonic radiation (PLHR) has become an increasing concern. Based on the observed data of 6.5 operating years of DEMETER satellite, by scanning the electric field power density time-frequency spectrograms, 133 PLHR events with central frequencies from 500 Hz to 4.5 kHz are detected in the near-Earth space above China. Among the 133 events, 129 events have PLE events at the base power system frequency (50 Hz in China). The duration time of every PLE event covers that of the corresponding PLHR event totally. As the same with PLHR, PLE is also propagating in whistler mode in the ionosphere. In two events that are detected in the conjugate region of Australian NWC VLF transmitter, radiations with line structure in the vicinity of 19.8 kHz are detected. There are 5 lines distributed from about 19.7 kHz to 19.9 kHz, which are in accordance with the frequency range of NWC transmitted signals. The frequency spacing of the 5 lines is exactly 50 Hz and the bandwidth of each line is about 10 Hz. The electric field power density of the line structure radiation is at the same level with the corresponding PLE, much higher than that of PLHR. The line structure radiations suggest possible modulation of VLF signals by PLE. At last, the variation of ionospheric parameters measured by DEMETER in relation with PLHR is analyzed statistically. As the revisiting orbits of DEMETER pass over the same area with nearly no deviation and at the same time of day, for each PLHR event, we check and average the parameters of 3 revisiting orbits before and after the event respectively. Combined with the event orbit, the variations of these parameters can be obtained. There are totally 5 tendencies: no variation, ascending, descending, crest and trough. Only a few events show no variation. Though there are differences in other 4 tendencies, none of the parameters show extremely preferences on one of the 4 tendencies. The crest and trough events are generally more than ascending and descending events, especially for ion density and O+ ion percentage. The variations of parameters show no preferences on latitude and the day of year.

  5. Calcium Input Frequency, Duration and Amplitude Differentially Modulate the Relative Activation of Calcineurin and CaMKII

    PubMed Central

    Li, Lu; Stefan, Melanie I.; Le Novère, Nicolas

    2012-01-01

    NMDA receptor dependent long-term potentiation (LTP) and long-term depression (LTD) are two prominent forms of synaptic plasticity, both of which are triggered by post-synaptic calcium elevation. To understand how calcium selectively stimulates two opposing processes, we developed a detailed computational model and performed simulations with different calcium input frequencies, amplitudes, and durations. We show that with a total amount of calcium ions kept constant, high frequencies of calcium pulses stimulate calmodulin more efficiently. Calcium input activates both calcineurin and Ca2+/calmodulin-dependent protein kinase II (CaMKII) at all frequencies, but increased frequencies shift the relative activation from calcineurin to CaMKII. Irrespective of amplitude and duration of the inputs, the total amount of calcium ions injected adjusts the sensitivity of the system to calcium input frequencies. At a given frequency, the quantity of CaMKII activated is proportional to the total amount of calcium. Thus, an input of a small amount of calcium at high frequencies can induce the same activation of CaMKII as a larger amount, at lower frequencies. Finally, the extent of activation of CaMKII signals with high calcium frequency is further controlled by other factors, including the availability of calmodulin, and by the potency of phosphatase inhibitors. PMID:22962589

  6. Lexical frequency effects on articulation: a comparison of picture naming and reading aloud

    PubMed Central

    Mousikou, Petroula; Rastle, Kathleen

    2015-01-01

    The present study investigated whether lexical frequency, a variable that is known to affect the time taken to utter a verbal response, may also influence articulation. Pairs of words that differed in terms of their relative frequency, but were matched on their onset, vowel, and number of phonemes (e.g., map vs. mat, where the former is more frequent than the latter) were used in a picture naming and a reading aloud task. Low-frequency items yielded slower response latencies than high-frequency items in both tasks, with the frequency effect being significantly larger in picture naming compared to reading aloud. Also, initial-phoneme durations were longer for low-frequency items than for high-frequency items. The frequency effect on initial-phoneme durations was slightly more prominent in picture naming than in reading aloud, yet its size was very small, thus preventing us from concluding that lexical frequency exerts an influence on articulation. Additionally, initial-phoneme and whole-word durations were significantly longer in reading aloud compared to picture naming. We discuss our findings in the context of current theories of reading aloud and speech production, and the approaches they adopt in relation to the nature of information flow (staged vs. cascaded) between cognitive and articulatory levels of processing. PMID:26528223

  7. Recognition of Frequency Modulated Whistle-Like Sounds by a Bottlenose Dolphin (Tursiops truncatus) and Humans with Transformations in Amplitude, Duration and Frequency.

    PubMed

    Branstetter, Brian K; DeLong, Caroline M; Dziedzic, Brandon; Black, Amy; Bakhtiari, Kimberly

    2016-01-01

    Bottlenose dolphins (Tursiops truncatus) use the frequency contour of whistles produced by conspecifics for individual recognition. Here we tested a bottlenose dolphin's (Tursiops truncatus) ability to recognize frequency modulated whistle-like sounds using a three alternative matching-to-sample paradigm. The dolphin was first trained to select a specific object (object A) in response to a specific sound (sound A) for a total of three object-sound associations. The sounds were then transformed by amplitude, duration, or frequency transposition while still preserving the frequency contour of each sound. For comparison purposes, 30 human participants completed an identical task with the same sounds, objects, and training procedure. The dolphin's ability to correctly match objects to sounds was robust to changes in amplitude with only a minor decrement in performance for short durations. The dolphin failed to recognize sounds that were frequency transposed by plus or minus ½ octaves. Human participants demonstrated robust recognition with all acoustic transformations. The results indicate that this dolphin's acoustic recognition of whistle-like sounds was constrained by absolute pitch. Unlike human speech, which varies considerably in average frequency, signature whistles are relatively stable in frequency, which may have selected for a whistle recognition system invariant to frequency transposition.

  8. Recognition of Frequency Modulated Whistle-Like Sounds by a Bottlenose Dolphin (Tursiops truncatus) and Humans with Transformations in Amplitude, Duration and Frequency

    PubMed Central

    Branstetter, Brian K.; DeLong, Caroline M.; Dziedzic, Brandon; Black, Amy; Bakhtiari, Kimberly

    2016-01-01

    Bottlenose dolphins (Tursiops truncatus) use the frequency contour of whistles produced by conspecifics for individual recognition. Here we tested a bottlenose dolphin’s (Tursiops truncatus) ability to recognize frequency modulated whistle-like sounds using a three alternative matching-to-sample paradigm. The dolphin was first trained to select a specific object (object A) in response to a specific sound (sound A) for a total of three object-sound associations. The sounds were then transformed by amplitude, duration, or frequency transposition while still preserving the frequency contour of each sound. For comparison purposes, 30 human participants completed an identical task with the same sounds, objects, and training procedure. The dolphin’s ability to correctly match objects to sounds was robust to changes in amplitude with only a minor decrement in performance for short durations. The dolphin failed to recognize sounds that were frequency transposed by plus or minus ½ octaves. Human participants demonstrated robust recognition with all acoustic transformations. The results indicate that this dolphin’s acoustic recognition of whistle-like sounds was constrained by absolute pitch. Unlike human speech, which varies considerably in average frequency, signature whistles are relatively stable in frequency, which may have selected for a whistle recognition system invariant to frequency transposition. PMID:26863519

  9. Analysis of fabric materials cut using ultraviolet laser ablation

    NASA Astrophysics Data System (ADS)

    Tsai, Hsin-Yi; Yang, Chih-Chung; Hsiao, Wen-Tse; Huang, Kuo-Cheng; Andrew Yeh, J.

    2016-04-01

    Laser ablation technology has widely been applied in the clothing industry in recent years. However, the laser mechanism would affect the quality of fabric contours and its components. Hence, this study examined carbonization and oxidation conditions and contour variation in nonwoven, cotton, and composite leather fabrics cut by using an ultraviolet laser at a wavelength of 355 nm. Processing parameters such as laser power, pulse frequency, scanning speed, and number of pulses per spot were adjusted to investigate component variation of the materials and to determine suitable cutting parameters for the fabrics. The experimental results showed that the weights of the component changed substantially by pulse frequency but slightly by laser power, so pulse frequency of 100 kHz and laser power of 14 W were the approximate parameters for three fabrics for the smaller carbonization and a sufficient energy for rapidly cutting, which the pulse duration of laser system was fixed at 300 μs and laser irradiance was 0.98 J/mm2 simultaneously. In addition, the etiolate phenomenon of nonwoven was reduced, and the component weight of cotton and composite leather was closed to the value of knife-cut fabric as the scanning speed increased. The approximate scanning speed for nonwoven and composite leather was 200 mm/s, and one for cotton was 150 mm/s, respectively. The sharper and firmer edge is obtained by laser ablation mechanism in comparison with traditional knife cutting. Experimental results can serve as the reference for laser cutting in the clothing industry, for rapidly providing smoother patterns with lower carbonization and oxidation edge in the fashion industry.

  10. [Experience of high frequency electric welding in endocrine surgery].

    PubMed

    Nychytaĭlo, M Iu; Lytvynenko, O M; Hul'ko, O M; Kvacheniuk, A M; Suprun, I S; Negriienko, K V; Kvacheniuk, D A

    2013-08-01

    The comparative analsis of the effectiveness of surgical interventions performed by the standard method and using electric welding technology in endocrine surgery was hold. Compared duration of surgery, amount of intraoperatve blood loss, frequency of intra- and early postoperative complications. Found that the use of weding technology ensures shorter duration of surgery, on average by 30%, amount of blood loss--by 20-50%, the frequency of intra- and early postoperative complications.

  11. Eye and Head Movement Characteristics in Free Visual Search of Flight-Simulator Imagery

    DTIC Science & Technology

    2010-03-01

    conspicuity. However, only gaze amplitude varied significantly with IFOV. A two- parameter (scale and exponent) power function was fitted to the...main-sequence amplitude-duration data. Both parameters varied significantly with target conspicuity, but in opposite directions. Neither parameter ...IFOV. A two- parameter (scale and exponent) power function was fitted to the main-sequence amplitude-duration data. Both parameters varied

  12. Recent enhancements of the PMCC infrasound signal detector

    NASA Astrophysics Data System (ADS)

    Brachet, N.; Mialle, P.; Matoza, R. S.; Le Pichon, A.; Cansi, Y.; Ceranna, L.

    2010-12-01

    The Progressive Multi-Channel Correlation (PMCC) is an antenna technique that is commonly being used by the scientific community for detecting coherent signals recorded on infrasound arrays. The PMCC detector, originally developed by CEA/DASE (Cansi, 1995), was installed in 2004 in the operational environment of the International Data Centre (IDC) of the Comprehensive nuclear Test Ban Treaty Organization (CTBTO) in Vienna. During the last 5 years, several changes have been made by the IDC to enhance the PMCC source code and parameter configuration, and the detector has exhibited good performance in terms of detection sensitivity and robustness. Recent studies performed at the CEA/DASE have shown that the IDC version (DFX/Geotool-PMCC) and the DASE version (WinPMCC) of PMCC software benefit from the implementation of the adaptive processing window duration and a log-spaced frequency bands. This tested configuration enables better detection and characterization of all received signals in their wave-front parameter space (e.g., frequency-azimuth space, frequency-trace-velocity space). A new release of the WinPMCC software - running under Windows or Linux operating systems - including a fully configurable filtering and detection parameters is now available upon request. We present the results of a statistical analysis on 10 years of infrasound data recorded at the IMS stations IS26, Germany and IS22, New Caledonia. A comparison is made between the automatic detections produced by the IDC, and the reprocessed detections using the optimized filtering and detection configuration parameters. Work is also underway at the CEA/DASE to determine more rigorously the azimuth and speed uncertainties. The current algorithm estimates the uncertainties based on statistical analysis of the distribution of PMCC detection pixels in the azimuth-speed space. The new code that is being considered performs the calculation of infrasound measurement errors as a function of physical parameters, i.e. dependant on the array geometry and the wave properties.

  13. Frequency of urinary tract infection in dogs with inflammatory skin disorders treated with ciclosporin alone or in combination with glucocorticoid therapy: a retrospective study.

    PubMed

    Peterson, Andrea L; Torres, Sheila M F; Rendahl, Aaron; Koch, Sandra N

    2012-06-01

    Few studies have investigated the frequency of urinary tract infection (UTI) in dogs receiving long-term ciclosporin therapy. The goal of the study was to investigate the frequency of UTI in dogs receiving ciclosporin with or without glucocorticoids. A secondary goal was to determine whether bacteriuria, pyuria and urine specific gravity were good predictors of UTI, and if ciclosporin dose, concurrent ketoconazole therapy, sex or duration of therapy affected the frequency of UTI. Animals -  Eighty-seven dogs with various inflammatory skin disorders and 59 control dogs with inflammatory skin conditions that had not received glucocorticoids or ciclosporin for 6 months were enrolled. This study was retrospective. The first urine culture from dogs receiving ciclosporin was compared with control dogs using Fisher's exact test. A logistic mixed model was used to test for association between a positive bacterial culture and duration of treatment, dose of ciclosporin, concurrent ketoconazole therapy and sex. The sensitivities and specificities for bacteriuria, pyuria and urine specific gravity were determined. Twenty-six of 87 (30%) ciclosporin-treated dogs had at least one positive culture. Compared with 3% positive control samples, 15% were positive in treated dogs (P=0.027). The sensitivity and specificity were, respectively, 64.1 and 98.1% for bacteriuria, 74.4 and 70.9% for pyuria, and 56.4 and 65.3% for urine specific gravity. All other analysed parameters were not significantly different. The results suggest that routine urine cultures and assessment of bacteriuria by cystocentesis should be part of the monitoring for dogs on long-term ciclosporin with and without glucocorticoids. © 2012 The Authors. Veterinary Dermatology. © 2012 ESVD and ACVD.

  14. A Quantitative Analysis of Pulsed Signals Emitted by Wild Bottlenose Dolphins.

    PubMed

    Luís, Ana Rita; Couchinho, Miguel N; Dos Santos, Manuel E

    2016-01-01

    Common bottlenose dolphins (Tursiops truncatus), produce a wide variety of vocal emissions for communication and echolocation, of which the pulsed repertoire has been the most difficult to categorize. Packets of high repetition, broadband pulses are still largely reported under a general designation of burst-pulses, and traditional attempts to classify these emissions rely mainly in their aural characteristics and in graphical aspects of spectrograms. Here, we present a quantitative analysis of pulsed signals emitted by wild bottlenose dolphins, in the Sado estuary, Portugal (2011-2014), and test the reliability of a traditional classification approach. Acoustic parameters (minimum frequency, maximum frequency, peak frequency, duration, repetition rate and inter-click-interval) were extracted from 930 pulsed signals, previously categorized using a traditional approach. Discriminant function analysis revealed a high reliability of the traditional classification approach (93.5% of pulsed signals were consistently assigned to their aurally based categories). According to the discriminant function analysis (Wilk's Λ = 0.11, F3, 2.41 = 282.75, P < 0.001), repetition rate is the feature that best enables the discrimination of different pulsed signals (structure coefficient = 0.98). Classification using hierarchical cluster analysis led to a similar categorization pattern: two main signal types with distinct magnitudes of repetition rate were clustered into five groups. The pulsed signals, here described, present significant differences in their time-frequency features, especially repetition rate (P < 0.001), inter-click-interval (P < 0.001) and duration (P < 0.001). We document the occurrence of a distinct signal type-short burst-pulses, and highlight the existence of a diverse repertoire of pulsed vocalizations emitted in graded sequences. The use of quantitative analysis of pulsed signals is essential to improve classifications and to better assess the contexts of emission, geographic variation and the functional significance of pulsed signals.

  15. Double-blind optimization of subcallosal cingulate deep brain stimulation for treatment-resistant depression: a pilot study.

    PubMed

    Ramasubbu, Rajamannar; Anderson, Susan; Haffenden, Angela; Chavda, Swati; Kiss, Zelma H T

    2013-09-01

    Deep brain stimulation (DBS) of the subcallosal cingulate (SCC) is reported to be a safe and effective new treatment for treatment-resistant depression (TRD). However, the optimal electrical stimulation parameters are unknown and generally selected by trial and error. This pilot study investigated the relationship between stimulus parameters and clinical effects in SCC-DBS treatment for TRD. Four patients with TRD underwent SCC-DBS surgery. In a double-blind stimulus optimization phase, frequency and pulse widths were randomly altered weekly, and corresponding changes in mood and depression were evaluated using a visual analogue scale (VAS) and the 17-item Hamilton Rating Scale for Depression (HAM-D-17). In the open-label postoptimization phase, depressive symptoms were evaluated biweekly for 6 months to determine long-term clinical outcomes. Longer pulse widths (270-450 μs) were associated with reductions in HAM-D-17 scores in 3 patients and maximal happy mood VAS responses in all 4 patients. Only 1 patient showed acute clinical or mood effects from changing the stimulation frequency. After 6 months of open-label therapy, 2 patients responded and 1 patient partially responded. Limitations include small sample size, weekly changes in stimulus parameters, and fixed-order and carry-forward effects. Longer pulse width stimulation may have a role in stimulus optimization for SCC-DBS in TRD. Longer pulse durations produce larger apparent current spread, suggesting that we do not yet know the optimal target or stimulus parameters for this therapy. Investigations using different stimulus parameters are required before embarking on large-scale randomized sham-controlled trials.

  16. Feeding and Reward Are Differentially Induced by Activating GABAergic Lateral Hypothalamic Projections to VTA.

    PubMed

    Barbano, M Flavia; Wang, Hui-Ling; Morales, Marisela; Wise, Roy A

    2016-03-09

    Electrical stimulation of the lateral hypothalamus (LH) has two motivational effects: long trains of stimulation induce drive-like effects such as eating, and short trains are rewarding. It has not been clear whether a single set of activated fibers subserves the two effects. Previous optogenetic stimulation studies have confirmed that reinforcement and induction of feeding can each be induced by selective stimulation of GABAergic fibers originating in the bed nucleus of the LH and projecting to the ventral tegmental area (VTA). In the present study we determined the optimal stimulation parameters for each of the two optogenetically induced effects in food-sated mice. Stimulation-induced eating was strongest with 5 Hz and progressively weaker with 10 and 20 Hz. Stimulation-induced reward was strongest with 40 Hz and progressively weaker with lower or higher frequencies. Mean preferred duration for continuous 40 Hz stimulation was 61.6 s in a "real-time" place preference task; mean preferred duration for 5 Hz stimulation was 45.6 s. The differential effects of high- and low-frequency stimulation of this pathway seem most likely to be due to differential effects on downstream targets. Copyright © 2016 the authors 0270-6474/16/362975-11$15.00/0.

  17. KOI-256's Magnetic Activity Under the Influence of the White Dwarf

    NASA Astrophysics Data System (ADS)

    Yoldaş, Ezgi; Dal, Hasan Ali

    2017-11-01

    We present the findings about chromospheric activity nature of KOI-256 obtained from the Kepler Mission data. First, it was found that there are some sinusoidal variations out-of-eclipses due to cool spot activity. The sinusoidal variations modelled by the spotmodel program indicate that the active component has two different active regions. Their longitudinal variation revealed that one of them has a migration period of 3.95 yrs, while the other has a migration period of 8.37 yrs. Second, 225 flares were detected from the short cadence data in total. The parameters, such as increase (T r) and decay (T d) times, total flare time (T t), equivalent durations (P), were calculated for each flare. The distribution of equivalent durations versus total flare times in logarithmic scale is modelled to find flare activity level. The Plateau value known as the saturation level of the active component was calculated to be 2.3121 ± 0.0964 s, and the Half-life value, which is required flare total time to reach the saturation, was computed to be 2233.6 s. In addition, the frequency of N 1, which is the number of flares per an hour in the system, was found to be 0.05087 h-1, while the flare frequency N 2 that the flare-equivalent duration emitting per an hour was found to be 0.00051. Contrary to the spot activity, it has been found that the flares are in tends to appear at specific phases due to the white dwarf component.

  18. Photonic generation of low phase noise arbitrary chirped microwave waveforms with large time-bandwidth product.

    PubMed

    Xie, Weilin; Xia, Zongyang; Zhou, Qian; Shi, Hongxiao; Dong, Yi; Hu, Weisheng

    2015-07-13

    We present a photonic approach for generating low phase noise, arbitrary chirped microwave waveforms based on heterodyne beating between high order correlated comb lines extracted from frequency-agile optical frequency comb. Using the dual heterodyne phase transfer scheme, extrinsic phase noises induced by the separate optical paths are efficiently suppressed by 42-dB at 1-Hz offset frequency. Linearly chirped microwave waveforms are achieved within 30-ms temporal duration, contributing to a large time-bandwidth product. The linearity measurement leads to less than 90 kHz RMS frequency error during the entire chirp duration, exhibiting excellent linearity for the microwave and sub-THz waveforms. The capability of generating arbitrary waveforms up to sub-THz band with flexible temporal duration, long repetition period, broad bandwidth, and large time-bandwidth product is investigated and discussed.

  19. Breastfeeding duration is associated with child diet at 6 years.

    PubMed

    Perrine, Cria G; Galuska, Deborah A; Thompson, Frances E; Scanlon, Kelley S

    2014-09-01

    Breastfeeding has been associated with early infant food preferences, but less is known about how breastfeeding is associated with later child diet. The objective of this study was to assess whether any and exclusive breastfeeding duration are associated with child diet at 6 years. We linked data from the Infant Feeding Practices Study II and Year 6 Follow-Up. We used approximately monthly questionnaires throughout infancy to calculate any and exclusive breastfeeding duration (n = 1355). We calculated median daily frequency of intake of water, milk, 100% juice, fruits, vegetables, sugar-sweetened beverages, sweets, and savory snacks at 6 years from a dietary screener and examined frequency of consumption of each food or beverage group by any and exclusive breastfeeding duration. We used separate multivariable logistic regression models to calculate odds of consuming more than the median daily frequency of intake of food or beverage items, adjusting for confounders. Intake of milk, sweets, and savory snacks at 6 years was not associated with any or exclusive breastfeeding duration in unadjusted analyses. Frequency of consumption of water, fruits, and vegetables was positively associated, and intake of sugar-sweetened beverages was inversely associated with any and exclusive breastfeeding duration in adjusted models; 100% juice consumption was inversely associated with exclusive breastfeeding duration only. Among many other health benefits, breastfeeding is associated with a number of healthier dietary behaviors at age 6. The association between breastfeeding and child diet may be an important factor to consider when examining associations between breastfeeding and child obesity and chronic diseases. Copyright © 2014 by the American Academy of Pediatrics.

  20. Ultraviolet germicidal efficacy as a function of pulsed radiation parameters studied by spore film dosimetry.

    PubMed

    Bauer, Stefan; Holtschmidt, Hans; Ott, Günter

    2018-01-01

    Disinfection by pulsed ultraviolet (UV) radiation is a commonly used method, e.g. in industry or medicine and can be carried out either with lasers or broadband UV radiation sources. Detrimental effects to biological materials depending on parameters such as pulse duration τ or pulse repetition frequency f p are well-understood for pulsed coherent UV radiation, however, relatively little is known for its incoherent variant. Therefore, within this work, it is the first time that disinfection rates of pulsed and continuous (cw) incoherent UV radiation studied by means of spore film dosimetry are presented, compared with each other, and in a second step further investigated regarding two pulse parameters. After analyzing the dynamic range of the Bacillus subtilis spore films with variable cw radiant exposures H=5-100Jm -2 a validation of the Bunsen-Roscoe law revealed its restricted applicability and a 28% enhanced detrimental effect of pulsed compared to cw incoherent UV radiation. A radiant exposure H=50Jm -2 and an irradiance E=0.5Wm -2 were found to be suitable parameters for an analysis of the disinfection rate as a function of τ=0.5-10ms and f p =25-500Hz unveiling that shorter pulses and lower frequencies inactivate more spores. Finally, the number of applied pulses as well as the experiment time were considered with regard to spore film disinfection. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Geographical variation in sound production in the anemonefish Amphiprion akallopisos.

    PubMed

    Parmentier, E; Lagardère, J P; Vandewalle, P; Fine, M L

    2005-08-22

    Because of pelagic-larval dispersal, coral-reef fishes are distributed widely with minimal genetic differentiation between populations. Amphiprion akallopisos, a clownfish that uses sound production to defend its anemone territory, has a wide but disjunct distribution in the Indian Ocean. We compared sounds produced by these fishes from populations in Madagascar and Indonesia, a distance of 6500 km. Differentiation of agonistic calls into distinct types indicates a complexity not previously recorded in fishes' acoustic communication. Moreover, various acoustic parameters, including peak frequency, pulse duration, number of peaks per pulse, differed between the two populations. The geographic comparison is the first to demonstrate 'dialects' in a marine fish species, and these differences in sound parameters suggest genetic divergence between these two populations. These results highlight the possible approach for investigating the role of sounds in fish behaviour in reproductive divergence and speciation.

  2. Post-stroke bacteriuria among stroke patients attending a physiotherapy clinic in Ghana: a cross-sectional study

    PubMed Central

    Donkor, Eric S; Akumwena, Amos; Amoo, Philip K; Owolabi, Mayowa O; Aspelund, Thor; Gudnason, Vilmundur

    2016-01-01

    Background Infections are known to be a major complication of stroke patients. In this study, we evaluated the risk of community-acquired bacteriuria among stroke patients, the associated factors, and the causative organisms. Methods This was a cross-sectional study involving 70 stroke patients and 83 age- and sex-matched, apparently healthy controls. Urine specimens were collected from all the study subjects and were analyzed by standard microbiological methods. Demographic and clinical information was also collected from the study subjects. For stroke patients, the information collected also included stroke parameters, such as stroke duration, frequency, and subtype. Results Bacteriuria was significantly higher among stroke patients (24.3%, n=17) than among the control group (7.2%, n=6), with a relative risk of 3.36 (confidence interval [CI], 1.40–8.01, P=0.006). Among the control group, all six bacteriuria cases were asymptomatic, whereas the 17 stroke bacteriuria cases comprised 15 cases of asymptomatic bacteriuria and two cases of symptomatic bacteriuria. Female sex (OR, 3.40; CI, 1.12–10.30; P=0.03) and presence of stroke (OR, 0.24; CI, 0.08–0.70; P=0.009) were significantly associated with bacteriuria. The etiology of bacteriuria was similar in both study groups, and coagulase-negative Staphylococcus spp. were the most predominant organisms isolated from both stroke patients (12.9%) and the control group (2.4%). Conclusion Stroke patients in the study region have a significantly higher risk of community-acquired bacteriuria, which in most cases is asymptomatic. Community-acquired bacteriuria in stroke patients appears to have little or no relationship with clinical parameters of stroke such as stroke subtype, duration and frequency. PMID:27051289

  3. Dynamics of convulsive seizure termination and postictal generalized EEG suppression

    PubMed Central

    Bauer, Prisca R.; Thijs, Roland D.; Lamberts, Robert J.; Velis, Demetrios N.; Visser, Gerhard H.; Tolner, Else A.; Sander, Josemir W.; Lopes da Silva, Fernando H.; Kalitzin, Stiliyan N.

    2017-01-01

    Abstract It is not fully understood how seizures terminate and why some seizures are followed by a period of complete brain activity suppression, postictal generalized EEG suppression. This is clinically relevant as there is a potential association between postictal generalized EEG suppression, cardiorespiratory arrest and sudden death following a seizure. We combined human encephalographic seizure data with data of a computational model of seizures to elucidate the neuronal network dynamics underlying seizure termination and the postictal generalized EEG suppression state. A multi-unit computational neural mass model of epileptic seizure termination and postictal recovery was developed. The model provided three predictions that were validated in EEG recordings of 48 convulsive seizures from 48 subjects with refractory focal epilepsy (20 females, age range 15–61 years). The duration of ictal and postictal generalized EEG suppression periods in human EEG followed a gamma probability distribution indicative of a deterministic process (shape parameter 2.6 and 1.5, respectively) as predicted by the model. In the model and in humans, the time between two clonic bursts increased exponentially from the start of the clonic phase of the seizure. The terminal interclonic interval, calculated using the projected terminal value of the log-linear fit of the clonic frequency decrease was correlated with the presence and duration of postictal suppression. The projected terminal interclonic interval explained 41% of the variation in postictal generalized EEG suppression duration (P < 0.02). Conversely, postictal generalized EEG suppression duration explained 34% of the variation in the last interclonic interval duration. Our findings suggest that postictal generalized EEG suppression is a separate brain state and that seizure termination is a plastic and autonomous process, reflected in increased duration of interclonic intervals that determine the duration of postictal generalized EEG suppression. PMID:28073789

  4. Acoustic, respiratory kinematic and electromyographic effects of vocal training

    NASA Astrophysics Data System (ADS)

    Mendes, Ana Paula De Brito Garcia

    The longitudinal effects of vocal training on the respiratory, phonatory and articulatory systems were investigated in this study. During four semesters, fourteen voice major students were recorded while speaking and singing. Acoustic, temporal, respiratory kinematic and electromyographic parameters were measured to determine changes in the three systems as a function of vocal training. Acoustic measures of the speaking voice included fundamental frequency, sound pressure level (SPL), percent jitter and shimmer, and harmonic-to-noise ratio. Temporal measures included duration of sentences, diphthongs and the closure durations of stop consonants. Acoustic measures of the singing voice included fundamental frequency and sound pressure level of the phonational range, vibrato pulses per second, vibrato amplitude variation and the presence of the singer's formant. Analysis of the data revealed that vocal training had a significant effect on the singing voice. Fundamental frequency and SPL of the 90% level and 90--10% of the phonational range increased significantly during four semesters of vocal training. Physiological data was collected from four subjects during three semesters of vocal training. Respiratory kinematic measures included lung volume, rib cage and abdominal excursions extracted from spoken sung samples. Descriptive statistics revealed that rib cage and abdominal excursions increased from the 1st to the 2nd semester and decrease from the 2nd to the 3rd semester of vocal training. Electromyographic measures of the pectoralis major, rectus abdominis and external obliques muscles revealed that burst duration means decreased from the 1st to the 2nd semester and increased from the 2nd to the 3rd semester. Peak amplitude means increased from the 1st to the 2nd and decreased from the 2nd to the 3rd semester of vocal training. Chest wall excursions and muscle force generation of the three muscles increased as the demanding level and the length of the phonatory tasks increased.

  5. Effects of Behavior-Contingent and Fixed-Time Release Contingencies on Frequency and Duration of Therapeutic Restraint

    ERIC Educational Resources Information Center

    Luiselli, James K.; Pace, Gary M.; Dunn, Erin K.

    2006-01-01

    Reducing therapeutic restraint is a desirable outcome for programs that serve individuals who exhibit challenging behaviors. This study investigated the effects of modifying the criterion for release from therapeutic restraint on frequency and duration. Release from restraint was changed from a behavior-contingent criterion (restraint terminated…

  6. Measurement Properties of a Park Use Questionnaire

    PubMed Central

    Evenson, Kelly R.; Wen, Fang; Golinelli, Daniela; Rodríguez, Daniel A.; Cohen, Deborah A.

    2012-01-01

    We determined the criterion validity and test-retest reliability of a brief park use questionnaire. From five US locations, 232 adults completed a brief survey four times and wore a global positioning system (GPS) monitor for three weeks. We assessed validity for park visits during the past week and during a usual week by examining agreement between frequency and duration of park visits reported in the questionnaire to the GPS monitor results. Spearman correlation coefficients (SCC) were used to measure agreement. For past week park visit frequency and duration, the SCC were 0.62–0.65 and 0.62–0.67, respectively. For usual week park visit frequency and duration, the SCC were 0.40–0.50 and 0.50–0.53, respectively. Usual park visit frequency reliability was 0.78–0.88 (percent agreement 69%–82%) and usual park visit duration was 0.75–0.84 (percent agreement 64%–73%). These results suggest that the questionnaire to assess usual and past week park use had acceptable validity and reliability. PMID:23853386

  7. Characterization of Titanium Oxide Layers Formation Produced by Nanosecond Laser Coloration

    NASA Astrophysics Data System (ADS)

    Brihmat-Hamadi, F.; Amara, E. H.; Kellou, H.

    2017-06-01

    Laser marking technique is used to produce colors on titanium while scanning a metallic sample under normal atmospheric conditions. To proceed with different operating conditions related to the laser beam, the parameters of a Q-switched diode-pumped Nd:YAG ( λ = 532 nm) laser, with a pulse duration of τ = 5 ns, are varied. The effect on the resulting mark quality is the aim of the present study which is developed to determine the influence of the operating parameters ( i.e., pulse frequency, beam scanning speed, and pumping intensity) and furthermore their combination, such as the accumulated fluences and the overlapping rate of laser impacts. From the obtained experimental results, it is noted that the accumulated fluences and the scanning speed are the most influential operating parameters during laser marking, since they have a strong effect on the surface roughness and reflectance, and the occurrence of many oxide phases such as TiO, Ti2O3, TiO2 ( γ- phase, anatase, and rutile).

  8. Dosage Parameters in Pediatric Outcome Studies Reported in 9 Peer-Reviewed Occupational Therapy Journals from 2008 to 2014: A Content Analysis

    PubMed Central

    Gee, Bryan M.; Lloyd, Kimberly; Devine, Nancy; Tyrrell, Erin; Evans, Trisha; Hill, Rebekah; Dineen, Stacee; Magalogo, Kristin

    2016-01-01

    Occupational therapists determine the dosage when establishing the plan of care for their pediatric clients. A content analysis was conducted using 123 pediatric occupational therapy outcomes studies from 9 scholarly international occupational therapy journals. The parameters of dosage were calculated using descriptive statistics in order to obtain a representation of dosage available within the current collage of pediatric occupational therapy outcomes studies. The results revealed that most studies reported portions of dosage parameters within the published studies. The average findings for the subcomponents related to dosage were session length (minutes) M = 58.7, duration of plan of care (weeks) M = 12.1, session frequency (per week) M = 3.4, and total hours of therapy (hours) M = 18.1. This first attempt at describing and calculating dosage related to pediatric occupational therapy practice indicates that evidence is lacking within the published literature to adequately guide OT dosage decisions. Further research related to dosage in pediatric occupational therapy practice is needed. PMID:26949547

  9. Seismic hazard along a crude oil pipeline in the event of an 1811-1812 type New Madrid earthquake. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hwang, H.H.M.; Chen, C.H.S.

    1990-04-16

    An assessment of the seismic hazard that exists along the major crude oil pipeline running through the New Madrid seismic zone from southeastern Louisiana to Patoka, Illinois is examined in the report. An 1811-1812 type New Madrid earthquake with moment magnitude 8.2 is assumed to occur at three locations where large historical earthquakes have occurred. Six pipeline crossings of the major rivers in West Tennessee are chosen as the sites for hazard evaluation because of the liquefaction potential at these sites. A seismologically-based model is used to predict the bedrock accelerations. Uncertainties in three model parameters, i.e., stress parameter, cutoffmore » frequency, and strong-motion duration are included in the analysis. Each parameter is represented by three typical values. From the combination of these typical values, a total of 27 earthquake time histories can be generated for each selected site due to an 1811-1812 type New Madrid earthquake occurring at a postulated seismic source.« less

  10. Timing and Duration of Flow in Ephemeral Streams of the Sierra Vista Subwatershed of the Upper San Pedro Basin, Cochise County, Southeastern Arizona

    USGS Publications Warehouse

    Gungle, Bruce

    2006-01-01

    Frequency, timing, and duration of streamflow were monitored in 20 ephemeral-stream channels across the Sierra Vista Subwatershed of the Upper San Pedro Basin, southeastern Arizona, during an 18-month period. One channel (Walnut Gulch) had Agricultural Research Service streamflow-gaging stations in place. The sediments of the remaining 19 ephemeral-stream channels were instrumented with multiple temperature loggers along the channel lengths. A thermograph-interpretation technique was developed in order to determine frequency, timing, and duration of streamflow in these channels. Streamflow onset was characterized by exceedance of a critical minimum drop in temperature within the channel sediments during any 15-minute interval, whereas streamflow cessation was identified by the local temperature minimum that immediately followed the critical temperature drop. All data for the 18-month period from December 1, 2000, to May 31, 2002, were analyzed in terms of monsoon (June 1 to September 19) and nonmonsoon (September 20 to May 31) periods. Nonmonsoon precipitation during the 2000-2002 study period (excludes October and November 2000) was 82 percent and 39 percent of the 30-year average, respectively, whereas monsoon precipitation during 2001 was 99 percent of the 30-year average. Ephemeral streamflow was detected at least once during the monitoring period at 87 percent of the monitoring sites (45 of the 52 sites that returned useful data; includes 4 streamflow-gaging stations). The summer monsoon period accounted for 82 percent of all streamflow events by number and 71 percent of all events by total streamflow duration. Nonmonsoon streamflow events peaked in number, total streamflow duration, and mean streamflow duration midway between the Huachuca Mountains and the San Pedro River on the west side of the subwatershed. These three streamflow parameters dropped off sharply about 10 kilometers from the mountain front. The number and total duration of nonmonsoon streamflows on the east side of the subwatershed trended downward with increased distance from the mountain fronts. Monsoon streamflow events were more evenly distributed across the subwatershed than nonmonsoon events, and the number and duration of streamflows generally trended upward with distance from the mountain fronts. Additional years of data are needed to determine whether these patterns are consistent year to year, or were due to randomness in the spatial distribution of precipitation. Streamflows in three ephemeral-stream channels were analyzed in detail. More than two-thirds of the streamflow events detected in each of these channels occurred at no more than one monitoring site along the channel length. In only one of the three channels-Garden Canyon-was a streamflow event detected at all logger sites along its length. Five temperature loggers provided data from urbanized areas, and these loggers detected streamflow more than 50 percent more often and of a duration nearly three times greater than did temperature loggers across the rural parts of the subwatershed. Because historical records do not indicate that more precipitation occurs in the urbanized area than in the rural areas, the increased frequency of flow detection in the urban area is attributed to an increase in runoff from the impervious surfaces throughout the urbanized area.

  11. Repetitive transcranial magnetic stimulator with controllable pulse parameters

    NASA Astrophysics Data System (ADS)

    Peterchev, Angel V.; Murphy, David L.; Lisanby, Sarah H.

    2011-06-01

    The characteristics of transcranial magnetic stimulation (TMS) pulses influence the physiological effect of TMS. However, available TMS devices allow very limited adjustment of the pulse parameters. We describe a novel TMS device that uses a circuit topology incorporating two energy storage capacitors and two insulated-gate bipolar transistor (IGBT) modules to generate near-rectangular electric field pulses with adjustable number, polarity, duration, and amplitude of the pulse phases. This controllable pulse parameter TMS (cTMS) device can induce electric field pulses with phase widths of 10-310 µs and positive/negative phase amplitude ratio of 1-56. Compared to conventional monophasic and biphasic TMS, cTMS reduces energy dissipation up to 82% and 57% and decreases coil heating up to 33% and 41%, respectively. We demonstrate repetitive TMS trains of 3000 pulses at frequencies up to 50 Hz with electric field pulse amplitude and width variability less than the measurement resolution (1.7% and 1%, respectively). Offering flexible pulse parameter adjustment and reduced power consumption and coil heating, cTMS enhances existing TMS paradigms, enables novel research applications and could lead to clinical applications with potentially enhanced potency.

  12. Repetitive transcranial magnetic stimulator with controllable pulse parameters.

    PubMed

    Peterchev, Angel V; Murphy, David L; Lisanby, Sarah H

    2011-06-01

    The characteristics of transcranial magnetic stimulation (TMS) pulses influence the physiological effect of TMS. However, available TMS devices allow very limited adjustment of the pulse parameters. We describe a novel TMS device that uses a circuit topology incorporating two energy storage capacitors and two insulated-gate bipolar transistor (IGBT) modules to generate near-rectangular electric field pulses with adjustable number, polarity, duration, and amplitude of the pulse phases. This controllable pulse parameter TMS (cTMS) device can induce electric field pulses with phase widths of 10-310 µs and positive/negative phase amplitude ratio of 1-56. Compared to conventional monophasic and biphasic TMS, cTMS reduces energy dissipation up to 82% and 57% and decreases coil heating up to 33% and 41%, respectively. We demonstrate repetitive TMS trains of 3000 pulses at frequencies up to 50 Hz with electric field pulse amplitude and width variability less than the measurement resolution (1.7% and 1%, respectively). Offering flexible pulse parameter adjustment and reduced power consumption and coil heating, cTMS enhances existing TMS paradigms, enables novel research applications and could lead to clinical applications with potentially enhanced potency.

  13. Food advertising on Australian television: Frequency, duration and monthly pattern of advertising from a commercial network (four channels) for the entire 2016.

    PubMed

    Smithers, Lisa G; Haag, Dandara G; Agnew, Benjamin; Lynch, John; Sorell, Matthew

    2018-04-16

    To estimate the frequency, duration and monthly pattern of discretionary food advertising on Australian free-to-air television. We logged 30 000 h of television collected in Adelaide during 2016 from one network that has four channels. The Australian Guide to Healthy Eating was used to identify discretionary foods. Data were examined according to all times, to children's peak viewing times (PVTs) and to when C-(children's) rated programmes may be broadcast. Of the >800 000 advertisements logged during 2016, 11% were for foods (n = 97 837). The most frequently advertised products were: snack foods (e.g. crisps), crumbed/battered meats, fast foods/take away meals and sweetened beverages. The frequency and duration of discretionary food advertising was 1.7 times/h and 0.5 min/h respectively at all times. During children's PVTs, the frequency and duration of discretionary food advertising was 2.3 times/h and 0.7 min/h, respectively. When C-rated programmes can be broadcast, the frequency and duration of discretionary food advertising was 1.8 times/h and 0.6 min/h, respectively. Across the year, discretionary foods ranged between 41% (August) and 71% (January) of all food advertising. Discretionary foods dominate food advertising. On average, discretionary food advertising was higher during PVTs for children and during the summer school holidays (January). © 2018 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  14. Far Infrared All-Sky Survey

    NASA Technical Reports Server (NTRS)

    Richards, Paul L.

    1998-01-01

    Precise measurements of the angular power spectrum of the Cosmic Microwave Background (CMB) anisotropy will revolutionize cosmology. These measurements will discriminate between competing cosmological models and, if the standard inflationary scenario is correct, will determine each of the fundamental cosmological parameters with high precision. The astrophysics community has recognized this potential: the orbital experiments MAP and PLANCK, have been approved to measure CMB anisotropy. Balloon-borne experiments can realize much of this potential before these missions are launched. Additionally, properly designed balloon-borne experiments can complement MAP in frequency and angular resolution and can give the first realistic test of the instrumentation proposed for the high frequency instrument on PLANCK. The MAXIMA experiment is part of the MAXIMA/BOOMERANG collaboration which is doing balloon observations of the angular power spectrum of the Cosmic Microwave Background from l = 10 to l = 800. These experiments are designed to use the benefits of both North American and Antarctic long-duration ballooning to full advantage. We have developed several new technologies that together allow the power spectrum to be measured with unprecedented combination of angular resolution, beam throw, sensitivity, sky coverage and control of systematic effects. These technologies are the basis for the high frequency instrument for the PLANCK mission. Our measurements will strongly discriminate between models of the origin and evolution of structure in the universe and, for many models, will determine the value of the basic cosmological parameters to high precision.

  15. Variability of hydrological droughts in the conterminous United States, 1951 through 2014

    USGS Publications Warehouse

    Austin, Samuel H.; Wolock, David M.; Nelms, David L.

    2018-02-22

    Spatial and temporal variability in the frequency, duration, and severity of hydrological droughts across the conterminous United States (CONUS) was examined using monthly mean streamflow measured at 872 sites from 1951 through 2014. Hydrological drought is identified as starting when streamflow falls below the 20th percentile streamflow value for 3 consecutive months and ending when streamflow remains above the 20th percentile streamflow value for 3 consecutive months. Mean drought frequency for all aggregated ecoregions in CONUS is 16 droughts per 100 years. Mean drought duration is 5 months, and mean drought severity is 39 percent on a scale ranging from 0 percent to 100 percent (with 100% being the most severe). Hydrological drought frequency is highest in the Western Mountains aggregated ecoregion and lowest in the Eastern Highlands, Northeast, and Southeast Plains aggregated ecoregions. Hydrological drought frequencies of 17 or more droughts per 100 years were found for the Central Plains, Southeast Coastal Plains, Western Mountains, and Western Xeric aggregated ecoregions. Drought duration and severity indicate spatial variability among the sites, but unlike drought frequency, do not show coherent spatial patterns. A comparison of an older period (1951–82) with a recent period (1983–2014) indicates few sites have statistically significant changes in drought frequency, drought duration, or drought severity at a 95-percent confidence level.

  16. Comparison of Indo-Pacific humpback dolphin (Sousa chinensis) whistles from two areas of western Peninsular Malaysia.

    PubMed

    Hoffman, Jordan M; Ponnampalam, Louisa S; Araújo, Claryana C; Wang, John Y; Kuit, Sui Hyang; Hung, Samuel K

    2015-11-01

    Differences in the acoustic variables of whistles emitted by Indo-Pacific humpback dolphins (Sousa chinensis) from two coastal locations along western Peninsular Malaysia were investigated. Duration, frequency, and frequency modulation variables were extracted from and used to characterize recordings of free-ranging humpback dolphins that were made using a broadband towed hydrophone. A total of 960 whistles from Matang Mangroves and 823 whistles from Langkawi Island were used in analyses. The whistles of Malaysian humpback dolphins covered frequencies from 1231 to 27 120 Hz with durations from 0.010-1.575 s. Significant multivariate differences were found in whistles emitted between locations. Significant differences were also found between dolphins of the two locations in their whistle duration, frequency modulation, and all frequency variables except for minimum frequency, which is likely under morphological constraints. The differences in whistles may be related to adaptations to the local acoustic habitat or unique whistles may have developed due to social interactions within each location, or broader scale differences resulting from geographic separation between the locations.

  17. Coping and sickness absence

    PubMed Central

    Schaufeli, Wilmar B.; van Dijk, Frank J. H.; Blonk, Roland W. B.

    2007-01-01

    Objectives The aim of this study is to examine the role of coping styles in sickness absence. In line with findings that contrast the reactive–passive focused strategies, problem-solving strategies are generally associated with positive results in terms of well-being and overall health outcomes; our hypothesis is that such strategies are positively related to a low frequency of sickness absence and with short lengths (total number of days absent) and durations (mean duration per spell). Methods Using a prospective design, employees’ (N = 3,628) responses on a self-report coping inventory are used to predict future registered sickness absence (i.e. frequency, length, duration, and median time before the onset of a new sick leave period). Results and conclusions In accordance with our hypothesis, and after adjustment for potential confounders, employees with an active problem-solving coping strategy are less likely to drop out because of sickness absence in terms of frequency, length (longer than 14 days), and duration (more than 7 days) of sickness absence. This positive effect is observed in the case of seeking social support only for the duration of sickness absence and in the case of palliative reaction only for the length and frequency of absence. In contrast, an avoidant coping style, representing a reactive–passive strategy, increases the likelihood of frequent absences significantly, as well as the length and duration of sickness absence. Expression of emotions, representing another reactive–passive strategy, has no effect on future sickness absenteeism. The median time before the onset of a new episode of absenteeism is significantly extended for active problem-solving and reduced for avoidance and for a palliative response. The results of the present study support the notion that problem-solving coping and reactive–passive strategies are inextricably connected to frequency, duration, length and onset of sickness absence. Especially, active problem-solving decreases the chance of future sickness absence. PMID:17701200

  18. Coping and sickness absence.

    PubMed

    van Rhenen, Willem; Schaufeli, Wilmar B; van Dijk, Frank J H; Blonk, Roland W B

    2008-02-01

    The aim of this study is to examine the role of coping styles in sickness absence. In line with findings that contrast the reactive-passive focused strategies, problem-solving strategies are generally associated with positive results in terms of well-being and overall health outcomes; our hypothesis is that such strategies are positively related to a low frequency of sickness absence and with short lengths (total number of days absent) and durations (mean duration per spell). Using a prospective design, employees' (N = 3,628) responses on a self-report coping inventory are used to predict future registered sickness absence (i.e. frequency, length, duration, and median time before the onset of a new sick leave period). In accordance with our hypothesis, and after adjustment for potential confounders, employees with an active problem-solving coping strategy are less likely to drop out because of sickness absence in terms of frequency, length (longer than 14 days), and duration (more than 7 days) of sickness absence. This positive effect is observed in the case of seeking social support only for the duration of sickness absence and in the case of palliative reaction only for the length and frequency of absence. In contrast, an avoidant coping style, representing a reactive-passive strategy, increases the likelihood of frequent absences significantly, as well as the length and duration of sickness absence. Expression of emotions, representing another reactive-passive strategy, has no effect on future sickness absenteeism. The median time before the onset of a new episode of absenteeism is significantly extended for active problem-solving and reduced for avoidance and for a palliative response. The results of the present study support the notion that problem-solving coping and reactive-passive strategies are inextricably connected to frequency, duration, length and onset of sickness absence. Especially, active problem-solving decreases the chance of future sickness absence.

  19. Differential changes in myoelectric characteristics of slow and fast fatigable frog muscle fibres during long-lasting activity.

    PubMed

    Vydevska-Chichova, M; Mileva, K; Radicheva, N

    2007-04-01

    The electrical activity of different muscle fibre types during fatigue at varying stimulation frequency and fibre stretch was studied. Extracellular action potentials (ECAPs) were recorded from isolated frog muscle fibres at initial length and stretched by 15%, 25% and 35% and stimulated for 180 s by suprathreshold pulses with frequencies of 5, 6.7 and 10Hz. The changes in ECAP negative phase duration (T(0)), propagation velocity of excitation (PV), potential power spectrum and its median frequency (MDF) were analysed for the period of uninterrupted activity (endurance time, ET). Slow (SMF) and fast (FMF) fatigable muscle fibre types were distinguished by the rate of PV decrease during ET. With the increase of stimulation frequency and fibre stretch, the rate of ECAP parameter changes increased and was larger in FMF, but this proportion was reversed with stretching over 25% and 10Hz stimulation. In both fibre types the power spectrum shift to lower frequencies during continuous activity was more pronounced with higher stimulation frequency. In FMFs the rates of MDF changes were positively and more strongly correlated with the rates of PV changes, whilst in SMFs the inverse correlation between the rates of changes of MDF and T(0) was stronger. The results indicate specific adaptation of slow and fast fatigable muscle fibres to stretch and activation frequency due to the differences in their membrane processes.

  20. Low- and high-frequency transcutaneous electrical nerve stimulation have no deleterious or teratogenic effects on pregnant mice.

    PubMed

    Yokoyama, L M; Pires, L A; Ferreira, E A Gonçalves; Casarotto, R A

    2015-06-01

    To evaluate the effects of application of transcutaneous electrical nerve stimulation (TENS) at low and high frequencies to the abdomens of Swiss mice throughout pregnancy. Experimental animal study. Research laboratory. Thirty Swiss mice received TENS throughout pregnancy. They were divided into three groups (n=10): placebo, low-frequency TENS (LF group) and high-frequency TENS (HF group). In the placebo group, the electrodes were applied to the abdominal region without any electrical current. In the LF group, the frequency was 10 Hz, pulse duration was 200 μs and intensity started at 2 mA. In the HF group, the same parameters were applied and the frequency was 150 Hz. All stimulation protocols were applied for 20 min/day from Day 0 until Day 20. The pregnant mice were weighed on Days 0, 7, 14 and 20 to verify weekly weight gain by two-way analysis of variance. The numbers of fetuses, placentas, implantations, resorptions and major external fetal malformations on Day 20 were analysed using the Kruskal-Wallis test. No significant differences were found between the placebo and TENS groups (P>0.05). Application of low- and high-frequency TENS to the abdomens of pregnant mice did not cause any deleterious or major teratogenic effects. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  1. Proficiency in English sentence stress production by Cantonese speakers who speak English as a second language (ESL).

    PubMed

    Ng, Manwa L; Chen, Yang

    2011-12-01

    The present study examined English sentence stress produced by native Cantonese speakers who were speaking English as a second language (ESL). Cantonese ESL speakers' proficiency in English stress production as perceived by English-speaking listeners was also studied. Acoustical parameters associated with sentence stress including fundamental frequency (F0), vowel duration, and intensity were measured from the English sentences produced by 40 Cantonese ESL speakers. Data were compared with those obtained from 40 native speakers of American English. The speech samples were also judged by eight native listeners who were native speakers of American English for placement, degree, and naturalness of stress. Results showed that Cantonese ESL speakers were able to use F0, vowel duration, and intensity to differentiate sentence stress patterns. Yet, both female and male Cantonese ESL speakers exhibited consistently higher F0 in stressed words than English speakers. Overall, Cantonese ESL speakers were found to be proficient in using duration and intensity to signal sentence stress, in a way comparable with English speakers. In addition, F0 and intensity were found to correlate closely with perceptual judgement and the degree of stress with the naturalness of stress.

  2. Assessment of duration of the drive operation in the mode of kinetic energy recovery under power supply voltage sags in electrical grids of mechanical engineering enterprises

    NASA Astrophysics Data System (ADS)

    Shonin, O. B.; Novozhilov, N. G.

    2017-02-01

    Voltage sags in electric grids of mechanical engineering enterprises may lead to disconnection of important power consumers with variable frequency drives from the power grid and further interruption of the production process. The paper considers a sensorless V/f control system of еру induction motor drive under normal conditions and under voltage sags on the basis of a computer model of the drive and derivation of a formula for assessment of possible duration of the drive operation in the mode of controlled recovery of kinetic energy accumulated in rotating mass of the drive. Results of simulations have been used to validate results of calculations of the rotor velocity deceleration made in a closed form obtained from the equation reflecting the balance of torques. It is shown that results of calculations practically coincide with results of simulations in the range up to 5% of the velocity initial value. The proposed formula may be useful for estimation of the duration of the drive operation in the mode of recovery of kinetic energy depending on parameters of the motor and driven mechanisms.

  3. A Quantitative Risk Assessment Model Involving Frequency and Threat Degree under Line-of-Business Services for Infrastructure of Emerging Sensor Networks.

    PubMed

    Jing, Xu; Hu, Hanwen; Yang, Huijun; Au, Man Ho; Li, Shuqin; Xiong, Naixue; Imran, Muhammad; Vasilakos, Athanasios V

    2017-03-21

    The prospect of Line-of-Business Services (LoBSs) for infrastructure of Emerging Sensor Networks (ESNs) is exciting. Access control remains a top challenge in this scenario as the service provider's server contains a lot of valuable resources. LoBSs' users are very diverse as they may come from a wide range of locations with vastly different characteristics. Cost of joining could be low and in many cases, intruders are eligible users conducting malicious actions. As a result, user access should be adjusted dynamically. Assessing LoBSs' risk dynamically based on both frequency and threat degree of malicious operations is therefore necessary. In this paper, we proposed a Quantitative Risk Assessment Model (QRAM) involving frequency and threat degree based on value at risk. To quantify the threat degree as an elementary intrusion effort, we amend the influence coefficient of risk indexes in the network security situation assessment model. To quantify threat frequency as intrusion trace effort, we make use of multiple behavior information fusion. Under the influence of intrusion trace, we adapt the historical simulation method of value at risk to dynamically access LoBSs' risk. Simulation based on existing data is used to select appropriate parameters for QRAM. Our simulation results show that the duration influence on elementary intrusion effort is reasonable when the normalized parameter is 1000. Likewise, the time window of intrusion trace and the weight between objective risk and subjective risk can be set to 10 s and 0.5, respectively. While our focus is to develop QRAM for assessing the risk of LoBSs for infrastructure of ESNs dynamically involving frequency and threat degree, we believe it is also appropriate for other scenarios in cloud computing.

  4. A Quantitative Risk Assessment Model Involving Frequency and Threat Degree under Line-of-Business Services for Infrastructure of Emerging Sensor Networks

    PubMed Central

    Jing, Xu; Hu, Hanwen; Yang, Huijun; Au, Man Ho; Li, Shuqin; Xiong, Naixue; Imran, Muhammad; Vasilakos, Athanasios V.

    2017-01-01

    The prospect of Line-of-Business Services (LoBSs) for infrastructure of Emerging Sensor Networks (ESNs) is exciting. Access control remains a top challenge in this scenario as the service provider’s server contains a lot of valuable resources. LoBSs’ users are very diverse as they may come from a wide range of locations with vastly different characteristics. Cost of joining could be low and in many cases, intruders are eligible users conducting malicious actions. As a result, user access should be adjusted dynamically. Assessing LoBSs’ risk dynamically based on both frequency and threat degree of malicious operations is therefore necessary. In this paper, we proposed a Quantitative Risk Assessment Model (QRAM) involving frequency and threat degree based on value at risk. To quantify the threat degree as an elementary intrusion effort, we amend the influence coefficient of risk indexes in the network security situation assessment model. To quantify threat frequency as intrusion trace effort, we make use of multiple behavior information fusion. Under the influence of intrusion trace, we adapt the historical simulation method of value at risk to dynamically access LoBSs’ risk. Simulation based on existing data is used to select appropriate parameters for QRAM. Our simulation results show that the duration influence on elementary intrusion effort is reasonable when the normalized parameter is 1000. Likewise, the time window of intrusion trace and the weight between objective risk and subjective risk can be set to 10 s and 0.5, respectively. While our focus is to develop QRAM for assessing the risk of LoBSs for infrastructure of ESNs dynamically involving frequency and threat degree, we believe it is also appropriate for other scenarios in cloud computing. PMID:28335569

  5. A Moment Rate Function Deduced from Peak Ground Motions from M 3.3-5.3 Earthquakes: Implications for Scaling, Corner Frequency and Stress Drop

    NASA Astrophysics Data System (ADS)

    Archuleta, R. J.; Ji, C.

    2016-12-01

    Based on 3827 records of peak horizontal ground motions in the NGA-West2 database we computed linear regressions for Log PGA, Log PGV and the ratio PGA/2πPGV (which we call dominant frequency, DomF) versus moment magnitude for M 3.3-5.3 earthquakes. The slopes are nearly one for Log PGA and Log PGV and negative one for PGA/PGV. For magnitudes 5.3 and smaller the source can be treated as a point source. Using these regressions and an expression between the half peak-to-peak amplitude of Wood Anderson records (PWA) and moment magnitude, we have deduced an `apparent' moment rate function (aMRF) that increases quadratically in time until it reaches its maximum at time tp after which it decays linearly until a final duration td. For t*=0.054 s and with parameters tp and td scaling with seismic moment, tp(M0) = 0.03[M0/ M0(M=3.3)]1/7.0 and td(M0) = 0.31[M0/ M0(M=3.3)]1/3.3 . all the magnitude dependence within M 3.3-5.3 can be explained. The Fourier amplitude spectrum (FAS) of the aMRF has two corner frequencies connected by an intermediate slope of f-1. The smaller corner frequency fC 1/ td, i.e., a corner frequency related to the full duration. Stress drop associated with the average over the fault scales weakly with seismic moment Δσ M00.09. The larger corner frequency is proportional to 1/ tp. We also find that DomF ≈ 1/[2.2(tp(M0) + t*)], thus there is a strong tradeoff between tp and t*. The higher corner frequency and the intermediate slope in the spectrum could be completely obscured by t* for t* 0.04-0.06 s, producing a Brune-type spectrum. If so, it will be practically impossible to retrieve the true spectrum. Because the fC derived from the spectrum is controlled by td while PGA and PGV are controlled mostly by the time scale tp, this aMRF could explain the difference in uncertainty of the mean stress drop inferred from peak ground motion data and that inferred from displacement amplitude spectra. This aMRF is consistent with a rupture that initiates from a critical crack length, e.g., Campillo and Ionescu (1997), Ohnaka (2000). In such a scenario, the peak time corresponds to rupture of the critical crack length with a stress change corresponding to breakdown stress, not stress drop. This is consistent with a stress parameter for predicting ground motion larger than the stress drop generally found by spectral studies.

  6. The electrical conductivity of in vivo human uterine fibroids.

    PubMed

    DeLonzor, Russ; Spero, Richard K; Williams, Joseph J

    2011-01-01

    The purpose of this study was to determine the value of electrical conductivity that can be used for numerical modelling in vivo radiofrequency ablation (RFA) treatments of human uterine fibroids. No experimental electrical conductivity data have previously been reported for human uterine fibroids. In this study electrical data (voltage) from selected in vivo clinical procedures on human uterine fibroids were used to numerically model the treatments. Measured versus calculated power dissipation profiles were compared to determine uterine fibroid electrical conductivity. Numerical simulations were conducted utilising a wide range of values for tissue thermal conductivity, heat capacity and blood perfusion coefficient. The simulations demonstrated that power dissipation was insensitive to the exact values of these parameters for the simulated geometry, treatment duration, and power level. Consequently, it was possible to determine tissue electrical conductivity without precise knowledge of the values for these parameters. Results of this study showed that an electrical conductivity for uterine fibroids of 0.305 S/m at 37°C and a temperature coefficient of 0.2%/°C can be used for modelling Radio Frequency Ablation of human uterine fibroids at a frequency of 460 kHz for temperatures from 37°C to 100°C.

  7. Temporal Characterization of Aircraft Noise Sources

    NASA Technical Reports Server (NTRS)

    Grosveld, Ferdinand W.; Sullivan, Brenda M.; Rizzi, Stephen A.

    2004-01-01

    Current aircraft source noise prediction tools yield time-independent frequency spectra as functions of directivity angle. Realistic evaluation and human assessment of aircraft fly-over noise require the temporal characteristics of the noise signature. The purpose of the current study is to analyze empirical data from broadband jet and tonal fan noise sources and to provide the temporal information required for prediction-based synthesis. Noise sources included a one-tenth-scale engine exhaust nozzle and a one-fifth scale scale turbofan engine. A methodology was developed to characterize the low frequency fluctuations employing the Short Time Fourier Transform in a MATLAB computing environment. It was shown that a trade-off is necessary between frequency and time resolution in the acoustic spectrogram. The procedure requires careful evaluation and selection of the data analysis parameters, including the data sampling frequency, Fourier Transform window size, associated time period and frequency resolution, and time period window overlap. Low frequency fluctuations were applied to the synthesis of broadband noise with the resulting records sounding virtually indistinguishable from the measured data in initial subjective evaluations. Amplitude fluctuations of blade passage frequency (BPF) harmonics were successfully characterized for conditions equivalent to take-off and approach. Data demonstrated that the fifth harmonic of the BPF varied more in frequency than the BPF itself and exhibited larger amplitude fluctuations over the duration of the time record. Frequency fluctuations were found to be not perceptible in the current characterization of tonal components.

  8. Perceptual and acoustic study of professionally trained versus untrained voices.

    PubMed

    Brown, W S; Rothman, H B; Sapienza, C M

    2000-09-01

    Acoustic and perceptual analyses were completed to determine the effect of vocal training on professional singers when speaking and singing. Twenty professional singers and 20 nonsingers, acting as the control, were recorded while sustaining a vowel, reading a modified Rainbow Passage, and singing "America the Beautiful." Acoustic measures included fundamental frequency, duration, percent jitter, percent shimmer, noise-to-harmonic ratio, and determination of the presence or absence of both vibrato and the singer's formant. Results indicated that, whereas certain acoustic parameters differentiated singers from nonsingers within sex, no consistently significant trends were found across males and females for either speaking or singing. The most consistent differences were the presence or absence of the singer's vibrato and formant in the singers versus the nonsingers, respectively. Perceptual analysis indicated that singers could be correctly identified with greater frequency than by chance alone from their singing, but not their speaking utterances.

  9. Seismic and infrasonic signals associated with an unusual collapse event at the Soufrière Hills volcano, Montserrat

    NASA Astrophysics Data System (ADS)

    Green, D. N.; Neuberg, J.

    2005-04-01

    In March 2004, during a period of no magma extrusion at Soufrière Hills volcano, Montserrat, an explosive event occurred with little precursory activity. Recorded broadband seismic signals ranged from an ultra-long-period signal with a dominant period of 120 s to impulsive, short-duration events containing frequencies up to 30 Hz. Synthetic displacement functions were fit to the long-period data after application of the seismometer response. These indicate a shallow collapse of the volcanic edifice occurred, initiated ~300 m below the surface, lasting ~100 s. Infrasonic tremor and pulses were also recorded in the 1-20 Hz range. The high-frequency seismicity and infrasound are interpreted as the subsequent collapse of a gravitationally unstable buttress of remnant dome material which impacted upon the edifice surface. This unique dataset demonstrates the benefits of deploying multi-parameter stations equipped with broadband instruments.

  10. Experimental study of fs-laser induced sub-100-nm periodic surface structures on titanium.

    PubMed

    Nathala, Chandra S R; Ajami, Ali; Ionin, Andrey A; Kudryashov, Sergey I; Makarov, Sergey V; Ganz, Thomas; Assion, Andreas; Husinsky, Wolfgang

    2015-03-09

    In this work the formation of laser-induced periodic surface structures (LIPSS) on a titanium surface upon irradiation by linearly polarized femtosecond (fs) laser pulses with a repetition rate of 1 kHz in air environment was studied experimentally. In particular, the dependence of high-spatial-frequency-LIPSS (HSFL) characteristics on various laser parameters: fluence, pulse number, wavelength (800 nm and 400 nm), pulse duration (10 fs - 550 fs), and polarization was studied in detail. In comparison with low-spatial-frequency-LIPSS (LSFL), the HSFL emerge at a much lower fluence with orientation perpendicular to the ridges of the LSFL. It was observed that these two types of LIPSS demonstrate different fluence, shot number and wavelength dependencies, which suggest their origin is different. Therefore, the HSFL formation mechanism cannot be described by the widely accepted interference model developed for describing LSFL formation.

  11. Model-based spectral estimation of Doppler signals using parallel genetic algorithms.

    PubMed

    Solano González, J; Rodríguez Vázquez, K; García Nocetti, D F

    2000-05-01

    Conventional spectral analysis methods use a fast Fourier transform (FFT) on consecutive or overlapping windowed data segments. For Doppler ultrasound signals, this approach suffers from an inadequate frequency resolution due to the time segment duration and the non-stationarity characteristics of the signals. Parametric or model-based estimators can give significant improvements in the time-frequency resolution at the expense of a higher computational complexity. This work describes an approach which implements in real-time a parametric spectral estimator method using genetic algorithms (GAs) in order to find the optimum set of parameters for the adaptive filter that minimises the error function. The aim is to reduce the computational complexity of the conventional algorithm by using the simplicity associated to GAs and exploiting its parallel characteristics. This will allow the implementation of higher order filters, increasing the spectrum resolution, and opening a greater scope for using more complex methods.

  12. Therapeutic effects of different durations of acupuncture on rats with middle cerebral artery occlusion

    PubMed Central

    Zhang, Chao; Wen, Yan; Fan, Xiao-nong; Tian, Guang; Zhou, Xue-yi; Deng, Shi-zhe; Meng, Zhi-hong

    2015-01-01

    Acupuncture is regarded as an effective therapy for cerebral ischemia. Different acupuncture manipulations and durations may result in different therapeutic effects. In the present study, the Neiguan (PC6) acupoint of rats with occluded middle cerebral arteries was needled at a fixed frequency (3 Hz) with different durations, i.e., 5, 60 and 180 seconds under a twisting-rotating acupuncture method. Results showed that different durations of acupuncture had different therapeutic effects, with 60 seconds yielding a better therapeutic effect than the other two groups. This duration of treatment demonstrated rapid cerebral blood flow, encouraging recovery of neurological function, and small cerebral infarct volume. Experimental findings indicated that under 3 Hz frequency, the treatment of needling Neiguan for 60 seconds is effective for ischemic stroke. PMID:25788938

  13. Speaking-rate-induced variability in F2 trajectories.

    PubMed

    Tjaden, K; Weismer, G

    1998-10-01

    This study examined speaking-rate-induced spectral and temporal variability of F2 formant trajectories for target words produced in a carrier phrase at speaking rates ranging from fast to slow. F2 onset frequency measured at the first glottal pulse following the stop consonant release in target words was used to quantify the extent to which adjacent consonantal and vocalic gestures overlapped; F2 target frequency was operationally defined as the first occurrence of a frequency minimum or maximum following F2 onset frequency. Regression analyses indicated 70% of functions relating F2 onset and vowel duration were statistically significant. The strength of the effect was variable, however, and the direction of significant functions often differed from that predicted by a simple model of overlapping, sliding gestures. Results of a partial correlation analysis examining interrelationships among F2 onset, F2 target frequency, and vowel duration across the speaking rate range indicated that covariation of F2 target with vowel duration may obscure the relationship between F2 onset and vowel duration across rate. The results further suggested that a sliding based model of acoustic variability associated with speaking rate change only partially accounts for the present data, and that such a view accounts for some speakers' data better than others.

  14. Predictive factors of adherence to frequency and duration components in home exercise programs for neck and low back pain: an observational study

    PubMed Central

    2009-01-01

    Background Evidence suggests that to facilitate physical activity sedentary people may adhere to one component of exercise prescriptions (intensity, duration or frequency) without adhering to other components. Some experts have provided evidence for determinants of adherence to different components among healthy people. However, our understanding remains scarce in this area for patients with neck or low back pain. The aims of this study are to determine whether patients with neck or low back pain have different rates of adherence to exercise components of frequency per week and duration per session when prescribed with a home exercise program, and to identify if adherence to both exercise components have distinct predictive factors. Methods A cohort of one hundred eighty-four patients with chronic neck or low back pain who attended physiotherapy in eight primary care centers were studied prospectively one month after intervention. The study had three measurement periods: at baseline (measuring characteristics of patients and pain), at the end of physiotherapy intervention (measuring characteristics of the home exercise program) and a month later (measuring professional behaviors during clinical encounters, environmental factors and self-efficacy, and adherence behavior). Results Adherence to duration per session (70.9% ± 7.1) was more probable than adherence to frequency per week (60.7% ± 7.0). Self-efficacy was a relevant factor for both exercise components (p < 0.05). The total number of exercises prescribed was predictive of frequency adherence (p < 0.05). Professional behaviors have a distinct influence on exercise components. Frequency adherence is more probable if patients received clarification of their doubts (adjusted OR: 4.1; p < 0.05), and duration adherence is more probable if they are supervised during the learning of exercises (adjusted OR: 3.3; p < 0.05). Conclusion We have shown in a clinic-based study that adherence to exercise prescription frequency and duration components have distinct levels and predictive factors. We recommend additional study, and advise that differential attention be given in clinical practice to each exercise component for improving adherence. PMID:19995464

  15. Radio afterglow rebrightening: evidence for multiple active phases in gamma-ray burst central engines

    NASA Astrophysics Data System (ADS)

    Li, Long-Biao; Zhang, Zhi-Bin; Rice, Jared

    2015-09-01

    The rebrightening phenomenon is an interesting feature in some X-ray, optical, and radio afterglows of gamma-ray bursts (GRBs). Here, we propose a possible energy-supply assumption to explain the rebrightenings of radio afterglows, in which the central engine with multiple active phases can supply at least two GRB pulses in a typical GRB duration time. Considering the case of double pulses supplied by the central engine, the double pulses have separate physical parameters, except for the number density of the surrounding interstellar medium (ISM). Their independent radio afterglows are integrated by the ground detectors to form the rebrightening phenomenon. In this Letter, we firstly simulate diverse rebrightening light curves under consideration of different and independent physical parameters. Using this assumption, we also give our best fit to the radio afterglow of GRB 970508 at three frequencies of 1.43, 4.86, and 8.46 GHz. We suggest that the central engine may be active continuously at a timescale longer than that of a typical GRB duration time as many authors have suggested (e.g., Zhang et al., Astrophys. J. 787:66, 2014; Gao and Mészáros, Astrophys. J. 802:90, 2015), and that it may supply enough energy to cause the long-lasting rebrightenings observed in some GRB afterglows.

  16. Differential impairments of selective attention due to frequency and duration of cannabis use.

    PubMed

    Solowij, N; Michie, P T; Fox, A M

    1995-05-15

    The evidence for long-term cognitive impairments associated with chronic use of cannabis has been inconclusive. We report the results of a brain event-related potential (ERP) study of selective attention in long-term cannabis users in the unintoxicated state. Two ERP measures known to reflect distinct components of attention were found to be affected differentially by duration and frequency of cannabis use. The ability to focus attention and filter out irrelevant information, measured by frontal processing negativity to irrelevant stimuli, was impaired progressively with the number of years of use but was unrelated to frequency of use. The speed of information processing, measured by the latency of parietal P300, was delayed significantly with increasing frequency of use but was unaffected by duration of use. The results suggest that a chronic buildup of cannabinoids produces both short- and long-term cognitive impairments.

  17. Older adults' personal routine at time of hospitalization.

    PubMed

    Zisberg, Anna; Gur-Yaish, Nurit

    This study is the first to explore whether hospitalization disrupts the daily routines of dependent and independent older adults. Data were collected as part of a prospectively designed study from 330 hospitalized older adults age 70+. Patients reported prehospitalization frequency, duration, and timing of basic activities of daily living and leisure activities at hospital admission. Hospital routine was assessed on day of discharge. Results indicated that frequency and duration of most basic activities decreased during hospitalization; the sharpest decrease was in frequency of getting dressed. Showering occurred 2 h earlier in the hospital setting, and getting dressed occurred an hour and a half later. For dependent respondents, the greatest change was in duration; for independent respondents, the greatest change was in frequency. Given the importance of routine maintenance to health and well-being, understanding the dynamics of its disruption in the hospital setting is imperative. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Dose-response patterns for vibration-induced white finger

    PubMed Central

    Griffin, M; Bovenzi, M; Nelson, C

    2003-01-01

    Aims: To investigate alternative relations between cumulative exposures to hand-transmitted vibration (taking account of vibration magnitude, lifetime exposure duration, and frequency of vibration) and the development of white finger (Raynaud's phenomenon). Methods: Three previous studies have been combined to provide a group of 1557 users of powered vibratory tools in seven occupational subgroups: stone grinders, stone carvers, quarry drillers, dockyard caulkers, dockyard boilermakers, dockyard painters, and forest workers. The estimated total operating duration in hours was thus obtained for each subject, for each tool, and for all tools combined. From the vibration magnitudes and exposure durations, seven alternative measurements of cumulative exposure were calculated for each subject, using expressions of the form: dose = ∑amiti, where ai is the acceleration magnitude on tool i, ti is the lifetime exposure duration for tool i, and m = 0, 1, 2, or 4. Results: For all seven alternative dose measures, an increase in dose was associated with a significant increase in the occurrence of vibration-induced white finger, after adjustment for age and smoking. However, dose measures with high powers of acceleration (m > 1) faired less well than measures in which the weighted or unweighted acceleration, and lifetime exposure duration, were given equal weight (m = 1). Dose determined solely by the lifetime exposure duration (without consideration of the vibration magnitude) gave better predictions than measures with m greater than unity. All measures of dose calculated from the unweighted acceleration gave better predictions than the equivalent dose measures using acceleration frequency-weighted according to current standards. Conclusions: Since the total duration of exposure does not discriminate between exposures accumulated over the day and those accumulated over years, a linear relation between vibration magnitude and exposure duration seems appropriate for predicting the occurrence of vibration-induced white finger. Poorer predictions were obtained when the currently recommended frequency weighting was employed than when accelerations at all frequencies were given equal weight. Findings suggest that improvements are possible to both the frequency weighting and the time dependency used to predict the development of vibration-induced white finger in current standards. PMID:12499452

  19. A neural network-based input shaping for swing suppression of an overhead crane under payload hoisting and mass variations

    NASA Astrophysics Data System (ADS)

    Ramli, Liyana; Mohamed, Z.; Jaafar, H. I.

    2018-07-01

    This paper proposes an improved input shaping for minimising payload swing of an overhead crane with payload hoisting and payload mass variations. A real time unity magnitude zero vibration (UMZV) shaper is designed by using an artificial neural network trained by particle swarm optimisation. The proposed technique could predict and directly update the shaper's parameters in real time to handle the effects of time-varying parameters during the crane operation with hoisting. To evaluate the performances of the proposed method, experiments are conducted on a laboratory overhead crane with a payload hoisting, different payload masses and two different crane motions. The superiority of the proposed method is confirmed by reductions of at least 38.9% and 91.3% in the overall and residual swing responses, respectively over a UMZV shaper designed using an average operating frequency and a robust shaper namely Zero Vibration Derivative-Derivative (ZVDD). The proposed method also demonstrates a significant residual swing suppression as compared to a ZVDD shaper designed based on varying frequency. In addition, the significant reductions are achieved with a less shaper duration resulting in a satisfactory speed of response. It is envisaged that the proposed method can be used for designing effective input shapers for payload swing suppression of a crane with time-varying parameters and for a crane that employ finite actuation states.

  20. Measurements of the Acoustic Speaking Voice After Vocal Warm-up and Cooldown in Choir Singers.

    PubMed

    Onofre, Fernanda; Prado, Yuka de Almeida; Rojas, Gleidy Vannesa E; Garcia, Denny Marco; Aguiar-Ricz, Lílian

    2017-01-01

    The aim of this study was to evaluate the acoustic measurements of the vowel /a/ in modal recording before and after a singing voice resistance test and after 30 minutes of absolute rest in female choir singers. This is a prospective cohort study. A total of 13 soprano choir singers with experience in choir singing were evaluated through analysis of acoustic voice parameters at three points in time: before continuous use of the voice, after vocal warm-up and a singing test 60 minutes in duration respecting the pauses for breathing, and after vocal cooldown and an absolute voice rest for 30 minutes. The fundamental frequency increased after the voice resistance test (P = 0.012) and remained elevated after the 30 minutes of voice rest (P = 0.01). The jitter decreased after the voice resistance test (P = 0.02) and after the 30 minutes of voice rest. A significant difference was detected for the acoustic voice parameters relative average perturbation (RAP), (P = 0.05), and pitch perturbation quotient (PPQ), (P = 0.04), compared with the initial time point. The fundamental frequency increased after 60 minutes of singing and remained elevated after vocal cooldown and absolute rest for 30 minutes, proving an efficient parameter for identifying the changes inherent to voice demand during singing. Copyright © 2017. Published by Elsevier Inc.

  1. CAN A NANOFLARE MODEL OF EXTREME-ULTRAVIOLET IRRADIANCES DESCRIBE THE HEATING OF THE SOLAR CORONA?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tajfirouze, E.; Safari, H.

    2012-01-10

    Nanoflares, the basic units of impulsive energy release, may produce much of the solar background emission. Extrapolation of the energy frequency distribution of observed microflares, which follows a power law to lower energies, can give an estimation of the importance of nanoflares for heating the solar corona. If the power-law index is greater than 2, then the nanoflare contribution is dominant. We model a time series of extreme-ultraviolet emission radiance as random flares with a power-law exponent of the flare event distribution. The model is based on three key parameters: the flare rate, the flare duration, and the power-law exponentmore » of the flare intensity frequency distribution. We use this model to simulate emission line radiance detected in 171 A, observed by Solar Terrestrial Relation Observatory/Extreme-Ultraviolet Imager and Solar Dynamics Observatory/Atmospheric Imaging Assembly. The observed light curves are matched with simulated light curves using an Artificial Neural Network, and the parameter values are determined across the active region, quiet Sun, and coronal hole. The damping rate of nanoflares is compared with the radiative losses cooling time. The effect of background emission, data cadence, and network sensitivity on the key parameters of the model is studied. Most of the observed light curves have a power-law exponent, {alpha}, greater than the critical value 2. At these sites, nanoflare heating could be significant.« less

  2. Prazosin for Prophylaxis of Chronic Post Traumatic Headaches in OEF/OIF/OND Service Members and Veterans with Mild TBI

    DTIC Science & Technology

    2016-10-01

    compared to placebo on HA frequency, HA severity and duration, use of abortive /analgesic medications, and HA-related disability. Specific Aim 2: To...the effect of prazosin compared to placebo on post- traumatic HA frequency, severity, duration, use of abortive /analgesic medications, and HA-related

  3. Gap Detection in School-Age Children and Adults: Center Frequency and Ramp Duration

    ERIC Educational Resources Information Center

    Buss, Emily; Porter, Heather L.; Hall, Joseph W., III; Grose, John H.

    2017-01-01

    Purpose: The age at which gap detection becomes adultlike differs, depending on the stimulus characteristics. The present study evaluated whether the developmental trajectory differs as a function of stimulus frequency region or duration of the onset and offset ramps bounding the gap. Method: Thresholds were obtained for wideband noise (500-4500…

  4. Optimisation of thulium fibre laser parameters with generation of pulses by pump modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Obronov, I V; Larin, S V; Sypin, V E

    2015-07-31

    The formation of relaxation pulses of a thulium fibre laser (λ = 1.9 μm) by modulating the power of a pump erbium fibre laser (λ = 1.55 μm) is studied. A theoretical model is developed to find the dependences of pulse duration and peak power on different cavity parameters. The optimal cavity parameters for achieving the minimal pulse duration are determined. The results are confirmed by experimental development of a laser emitting pulses with a duration shorter than 10 ns, a peak power of 1.8 kW and a repetition rate of 50 kHz. (control of radiation parameters)

  5. Iterative design of one- and two-dimensional FIR digital filters. [Finite duration Impulse Response

    NASA Technical Reports Server (NTRS)

    Suk, M.; Choi, K.; Algazi, V. R.

    1976-01-01

    The paper describes a new iterative technique for designing FIR (finite duration impulse response) digital filters using a frequency weighted least squares approximation. The technique is as easy to implement (via FFT) and as effective in two dimensions as in one dimension, and there are virtually no limitations on the class of filter frequency spectra approximated. An adaptive adjustment of the frequency weight to achieve other types of design approximation such as Chebyshev type design is discussed.

  6. Sherborne Missile Fire Frequency with Unconstraint Parameters

    NASA Astrophysics Data System (ADS)

    Dong, Shaquan

    2018-01-01

    For the modeling problem of shipborne missile fire frequency, the fire frequency models with unconstant parameters were proposed, including maximum fire frequency models with unconstant parameters, and actual fire frequency models with unconstant parameters, which can be used to calculate the missile fire frequency with unconstant parameters.

  7. The effect of severity of unilateral vestibular dysfunction on symptoms, disabilities and handicap in vertiginous patients.

    PubMed

    Bamiou, D E; Davies, R A; McKee, M; Luxon, L M

    1999-02-01

    This study compares the symptoms, disabilities and handicap, as assessed by means of a questionnaire, in two groups of patients with a unilateral peripheral vestibular disorder: those with a total canal paresis and those with a partial canal paresis, as judged by the duration parameter using the Fitzgerald Hallpike caloric test in the absence of optic fixation. The results of the study indicate that the severity of dizziness, the Dizziness Index (severity x frequency) and the overall level of disabilities related to visual vertigo are less severe in unilateral profound or total loss of vestibular function than in unilateral mild vestibular loss.

  8. Damage Accumulation in Cyclically-Loaded Glass-Ceramic Matrix Composites Monitored by Acoustic Emission

    PubMed Central

    Aggelis, D. G.; Dassios, K. G.; Kordatos, E. Z.; Matikas, T. E.

    2013-01-01

    Barium osumilite (BMAS) ceramic matrix composites reinforced with SiC-Tyranno fibers are tested in a cyclic loading protocol. Broadband acoustic emission (AE) sensors are used for monitoring the occurrence of different possible damage mechanisms. Improved use of AE indices is proposed by excluding low-severity signals based on waveform parameters, rather than only threshold criteria. The application of such improvements enhances the accuracy of the indices as accumulated damage descriptors. RA-value, duration, and signal energy follow the extension cycles indicating moments of maximum or minimum strain, while the frequency content of the AE signals proves very sensitive to the pull-out mechanism. PMID:24381524

  9. Urbanization Induces Nonstationarity in Extreme Rainfall Characteristics over Contiguous United States

    NASA Astrophysics Data System (ADS)

    Singh, J.; Paimazumder, D.; Mohanty, M. P.; Ghosh, S.; Karmakar, S.

    2017-12-01

    The statistical assumption of stationarity in hydrologic extreme time/event series has been relied heavily in frequency analysis. However, due to the perceivable impacts of climate change, urbanization and land use pattern, assumption of stationarity in hydrologic time series will draw erroneous results, which in turn may affect the policy and decision-making. Also, it may no longer be reasonable to model rainfall extremes as a stationary process, yet nearly all-existing infrastructure design, water resource planning methods assume that historical extreme rainfall events will remain unchanged in the future. Therefore, a comprehensive multivariate nonstationary frequency analysis has been conducted for the CONUS to identify the precipitation characteristics (intensity, duration and depth) responsible for significant nonstationarity. We use 0.250 resolution of precipitation data for a period of 1948-2006, in a Generalized Additive Model for Location, Scale and Shape (GAMLSS) framework. A cluster of 74 GAMLSS models has been developed by considering nonstationarity in different combinations of distribution parameters through different regression techniques, and the best-fit model is further applied for bivariate analysis. Next, four demographic variables i.e. population density, housing unit, low income population and population below poverty line, have been utilized to identify the urbanizing regions through developing urbanization index. Furthermore to strengthen the analysis, Land cover map for 1992, 2001 and 2006 have been utilized to identify the location with the high change in impervious surface. The results show significant differences in the 50- and 100-year intensity, volume and duration estimated under the both stationary and nonstationary condition in urbanizing regions. Further results exhibit that rainfall duration has been decreased while, rainfall volume has been increased under nonstationary condition, which indicates increasing flood potential of rainfall events. The present study facilitate the understanding of anthropogenic climate change to extreme rainfall characteristics i.e. intensity, volume and duration, which could be utilized in designing flood control structure through a proposed nonstationary modeling.

  10. Possible Electromagnetic Effects on Abnormal Animal Behavior Before an Earthquake

    PubMed Central

    Hayakawa, Masashi

    2013-01-01

    Simple Summary Possible electromagnetic effects on abnormal animal behavior before earthquakes. Abstract The former statistical properties summarized by Rikitake (1998) on unusual animal behavior before an earthquake (EQ) have first been presented by using two parameters (epicentral distance (D) of an anomaly and its precursor (or lead) time (T)). Three plots are utilized to characterize the unusual animal behavior; (i) EQ magnitude (M) versus D, (ii) log T versus M, and (iii) occurrence histogram of log T. These plots are compared with the corresponding plots for different seismo-electromagnetic effects (radio emissions in different frequency ranges, seismo-atmospheric and -ionospheric perturbations) extensively obtained during the last 15–20 years. From the results of comparisons in terms of three plots, it is likely that lower frequency (ULF (ultra-low-frequency, f ≤ 1 Hz) and ELF (extremely-low-frequency, f ≤ a few hundreds Hz)) electromagnetic emissions exhibit a very similar temporal evolution with that of abnormal animal behavior. It is also suggested that a quantity of field intensity multiplied by the persistent time (or duration) of noise would play the primary role in abnormal animal behavior before an EQ. PMID:26487307

  11. Statistics and classification of the microwave zebra patterns associated with solar flares

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Baolin; Tan, Chengming; Zhang, Yin

    2014-01-10

    The microwave zebra pattern (ZP) is the most interesting, intriguing, and complex spectral structure frequently observed in solar flares. A comprehensive statistical study will certainly help us to understand the formation mechanism, which is not exactly clear now. This work presents a comprehensive statistical analysis of a big sample with 202 ZP events collected from observations at the Chinese Solar Broadband Radio Spectrometer at Huairou and the Ondŕejov Radiospectrograph in the Czech Republic at frequencies of 1.00-7.60 GHz from 2000 to 2013. After investigating the parameter properties of ZPs, such as the occurrence in flare phase, frequency range, polarization degree,more » duration, etc., we find that the variation of zebra stripe frequency separation with respect to frequency is the best indicator for a physical classification of ZPs. Microwave ZPs can be classified into three types: equidistant ZPs, variable-distant ZPs, and growing-distant ZPs, possibly corresponding to mechanisms of the Bernstein wave model, whistler wave model, and double plasma resonance model, respectively. This statistical classification may help us to clarify the controversies between the existing various theoretical models and understand the physical processes in the source regions.« less

  12. In vitro characterization of perfluorocarbon droplets for focused ultrasound therapy

    NASA Astrophysics Data System (ADS)

    Schad, Kelly C.; Hynynen, Kullervo

    2010-09-01

    Focused ultrasound therapy can be enhanced with microbubbles by thermal and cavitation effects. However, localization of treatment is difficult as bioeffects can occur outside of the target region. Spatial control of bubbles can be achieved by ultrasound-induced conversion of liquid perfluorocarbon droplets to gas bubbles. This study was undertaken to determine the acoustic parameters for bubble production by droplet conversion and how it depends on the acoustic conditions and droplet physical parameters. Lipid-encapsulated droplets containing dodecafluoropentane were manufactured with sizes ranging from 1.9 to 7.2 µm in diameter and diluted to a concentration of 8 × 106 droplets mL-1. The droplets were sonicated in vitro with a focused ultrasound transducer and varying frequency and exposure under flow conditions through an acoustically transparent vessel. The sonications were 10 ms in duration at frequencies of 0.578, 1.736 and 2.855 MHz. The pressure threshold for droplet conversion was measured with an active transducer operating in pulse-echo mode and simultaneous measurements of broadband acoustic emissions were performed with passive acoustic detection. The results show that droplets cannot be converted at low frequency without broadband emissions occurring. However, the pressure threshold for droplet conversion decreased with increasing frequency, exposure and droplet size. The pressure threshold for broadband emissions was independent of the droplet size and was 2.9, 4.4 and 5.3 MPa for 0.578, 1736 and 2.855 MHz, respectively. In summary, we have demonstrated that droplet conversion is feasible for clinically relevant sized droplets and acoustic exposures.

  13. Assessment of Time and Frequency Domain Parameters of Heart Rate Variability and Interictal Cardiac Rhythm Abnormalities in Drug-naïve Patients with Idiopathic Generalized Epilepsy.

    PubMed

    Kilinc, Ozden; Cincin, Altug; Pehlivan, Aslihan; Midi, Ipek; Kepez, Alper; Agan, Kadriye

    2016-06-01

    Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures.

  14. In vitro characterization of perfluorocarbon droplets for focused ultrasound therapy.

    PubMed

    Schad, Kelly C; Hynynen, Kullervo

    2010-09-07

    Focused ultrasound therapy can be enhanced with microbubbles by thermal and cavitation effects. However, localization of treatment is difficult as bioeffects can occur outside of the target region. Spatial control of bubbles can be achieved by ultrasound-induced conversion of liquid perfluorocarbon droplets to gas bubbles. This study was undertaken to determine the acoustic parameters for bubble production by droplet conversion and how it depends on the acoustic conditions and droplet physical parameters. Lipid-encapsulated droplets containing dodecafluoropentane were manufactured with sizes ranging from 1.9 to 7.2 microm in diameter and diluted to a concentration of 8 x 10(6) droplets mL(-1). The droplets were sonicated in vitro with a focused ultrasound transducer and varying frequency and exposure under flow conditions through an acoustically transparent vessel. The sonications were 10 ms in duration at frequencies of 0.578, 1.736 and 2.855 MHz. The pressure threshold for droplet conversion was measured with an active transducer operating in pulse-echo mode and simultaneous measurements of broadband acoustic emissions were performed with passive acoustic detection. The results show that droplets cannot be converted at low frequency without broadband emissions occurring. However, the pressure threshold for droplet conversion decreased with increasing frequency, exposure and droplet size. The pressure threshold for broadband emissions was independent of the droplet size and was 2.9, 4.4 and 5.3 MPa for 0.578, 1736 and 2.855 MHz, respectively. In summary, we have demonstrated that droplet conversion is feasible for clinically relevant sized droplets and acoustic exposures.

  15. Nanosecond electric pulses modulate skeletal muscle calcium dynamics and contraction

    NASA Astrophysics Data System (ADS)

    Valdez, Chris; Jirjis, Michael B.; Roth, Caleb C.; Barnes, Ronald A.; Ibey, Bennett L.

    2017-02-01

    Irreversible electroporation therapy is utilized to remove cancerous tissues thru the delivery of rapid (250Hz) and high voltage (V) (1,500V/cm) electric pulses across microsecond durations. Clinical research demonstrated that bipolar (BP) high voltage microsecond pulses opposed to monophasic waveforms relieve muscle contraction during electroporation treatment. Our group along with others discovered that nanosecond electric pulses (nsEP) can activate second messenger cascades, induce cytoskeletal rearrangement, and depending on the nsEP duration and frequency, initiate apoptotic pathways. Of high interest across in vivo and in vitro applications, is how nsEP affects muscle physiology, and if nuances exist in comparison to longer duration electroporation applications. To this end, we exposed mature skeletal muscle cells to monopolar (MP) and BP nsEP stimulation across a wide range of electric field amplitudes (1-20 kV/cm). From live confocal microscopy, we simultaneously monitored intracellular calcium dynamics along with nsEP-induced muscle movement on a single cell level. In addition, we also evaluated membrane permeability with Yo-PRO-1 and Propidium Iodide (PI) across various nsEP parameters. The results from our findings suggest that skeletal muscle calcium dynamics, and nsEP-induced contraction exhibit exclusive responses to both MP and BP nsEP exposure. Overall the results suggest in vivo nsEP application may elicit unique physiology and field applications compared to longer pulse duration electroporation.

  16. Electrical and contractile activities of the human rectosigmoid.

    PubMed Central

    Sarna, S; Latimer, P; Campbell, D; Waterfall, W E

    1982-01-01

    Electrical and mechanical activities were recorded from the rectosigmoid of normal subjects using an intraluminal recording tube with two sets of bipolar electrodes and strain gauges. Four distinct types of electrical activities were recorded. (1) Electrical control activity (ECA). This activity varied in amplitude and frequency over time and the control waves were not phase-locked. The means of dominant frequency components in the lower and higher frequency ranges were 3.86 +/- 0.18 SD and 10.41 +/- 0.46 SD c/min, respectively. The overall dominant frequency component was mostly in the lower frequency range of 2.0-9.0 c/min. (2) Discrete electrical response activity (DERA). This activity appeared as short duration bursts (less than 10 s) of response potentials whose repetition rate was in the total colonic electrical control activity frequency range of 2.0-13.0 c/min. The mean duration of this activity was 2.24 +/- 1.30 SD s. (3) Continuous electrical response activity (CERA). This activity appeared as long duration bursts (greater than 10 s) of response potentials which were not related to electrical control activity. Its mean duration was 14.78 +/- 3.68 SD s. This activity generally did not propagate. (4) Contractile electrical complex (CEC). This activity appeared as oscillations in the frequency range of 25-40 c/min and was also not related to electrical control activity. This activity propagated, sometimes proximally and sometimes distally. Its mean duration was 18.87 +/- 9.22 SD s. The latter three types of electrical activities were all associated with different types of contractions. These contractions, however, did not always occlude the lumen. Colonic electrical control activity controls the appearance of discrete electrical response activity in time and space. The mechanism of generation of continuous electrical response activity and contractile electrical complex is not yet known. PMID:7095566

  17. a Comparative Analysis of Fluent and Cerebral Palsied Speech.

    NASA Astrophysics Data System (ADS)

    van Doorn, Janis Lee

    Several features of the acoustic waveforms of fluent and cerebral palsied speech were compared, using six fluent and seven cerebral palsied subjects, with a major emphasis being placed on an investigation of the trajectories of the first three formants (vocal tract resonances). To provide an overall picture which included other acoustic features, fundamental frequency, intensity, speech timing (speech rate and syllable duration), and prevocalization (vocalization prior to initial stop consonants found in cerebral palsied speech) were also investigated. Measurements were made using repetitions of a test sentence which was chosen because it required large excursions of the speech articulators (lips, tongue and jaw), so that differences in the formant trajectories for the fluent and cerebral palsied speakers would be emphasized. The acoustic features were all extracted from the digitized speech waveform (10 kHz sampling rate): the fundamental frequency contours were derived manually, the intensity contours were measured using the signal covariance, speech rate and syllable durations were measured manually, as were the prevocalization durations, while the formant trajectories were derived from short time spectra which were calculated for each 10 ms of speech using linear prediction analysis. Differences which were found in the acoustic features can be summarized as follows. For cerebral palsied speakers, the fundamental frequency contours generally showed inappropriate exaggerated fluctuations, as did some of the intensity contours; the mean fundamental frequencies were either higher or the same as for the fluent subjects; speech rates were reduced, and syllable durations were longer; prevocalization was consistently present at the beginning of the test sentence; formant trajectories were found to have overall reduced frequency ranges, and to contain anomalous transitional features, but it is noteworthy that for any one cerebral palsied subject, the inappropriate trajectory pattern was generally reproducible. The anomalous transitional features took the form of (a) inappropriate transition patterns, (b) reduced frequency excursions, (c) increased transition durations, and (d) decreased maximum rates of frequency change.

  18. Bivariate drought frequency analysis using the copula method

    NASA Astrophysics Data System (ADS)

    Mirabbasi, Rasoul; Fakheri-Fard, Ahmad; Dinpashoh, Yagob

    2012-04-01

    Droughts are major natural hazards with significant environmental and economic impacts. In this study, two-dimensional copulas were applied to the analysis of the meteorological drought characteristics of the Sharafkhaneh gauge station, located in the northwest of Iran. Two major drought characteristics, duration and severity, as defined by the standardized precipitation index, were abstracted from observed drought events. Since drought duration and severity exhibited a significant correlation and since they were modeled using different distributions, copulas were used to construct the joint distribution function of the drought characteristics. The parameter of copulas was estimated using the method of the Inference Function for Margins. Several copulas were tested in order to determine the best data fit. According to the error analysis and the tail dependence coefficient, the Galambos copula provided the best fit for the observed drought data. Some bivariate probabilistic properties of droughts, based on the derived copula-based joint distribution, were also investigated. These probabilistic properties can provide useful information for water resource planning and management.

  19. Calling depths of baleen whales from single sensor data: development of an autocorrelation method using multipath localization.

    PubMed

    Valtierra, Robert D; Glynn Holt, R; Cholewiak, Danielle; Van Parijs, Sofie M

    2013-09-01

    Multipath localization techniques have not previously been applied to baleen whale vocalizations due to difficulties in application to tonal vocalizations. Here it is shown that an autocorrelation method coupled with the direct reflected time difference of arrival localization technique can successfully resolve location information. A derivation was made to model the autocorrelation of a direct signal and its overlapping reflections to illustrate that an autocorrelation may be used to extract reflection information from longer duration signals containing a frequency sweep, such as some calls produced by baleen whales. An analysis was performed to characterize the difference in behavior of the autocorrelation when applied to call types with varying parameters (sweep rate, call duration). The method's feasibility was tested using data from playback transmissions to localize an acoustic transducer at a known depth and location. The method was then used to estimate the depth and range of a single North Atlantic right whale (Eubalaena glacialis) and humpback whale (Megaptera novaeangliae) from two separate experiments.

  20. Statistical Distributions of Optical Flares from Gamma-Ray Bursts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yi, Shuang-Xi; Yu, Hai; Wang, F. Y.

    2017-07-20

    We statistically study gamma-ray burst (GRB) optical flares from the Swift /UVOT catalog. We compile 119 optical flares, including 77 flares with redshift measurements. Some tight correlations among the timescales of optical flares are found. For example, the rise time is correlated with the decay time, and the duration time is correlated with the peak time of optical flares. These two tight correlations indicate that longer rise times are associated with longer decay times of optical flares and also suggest that broader optical flares peak at later times, which are consistent with the corresponding correlations of X-ray flares. We alsomore » study the frequency distributions of optical flare parameters, including the duration time, rise time, decay time, peak time, and waiting time. Similar power-law distributions for optical and X-ray flares are found. Our statistic results imply that GRB optical flares and X-ray flares may share the similar physical origin, and both of them are possibly related to central engine activities.« less

  1. Cadaveric renal preservation with hyperosmolar, intracellular hypothermic washout solution and cold storage.

    PubMed

    Diethelm, A G; Blackstone, E H

    1978-07-01

    All 54 kidneys obtained from heart-beating cadavers functioned when preserved by a brief washout using a hypothermic, hyperosmolar, hyperkalemic perfusate, followed by cold storage. The duration of preservation ranged from two hours and 57 minutes to 39 hours and 47 minutes. Two other kidneys retrieved from a nonheart-beating cadaver and preserved by the same technique failed to function because of irreversible acute tubular necrosis. Fifty-six consecutive transplant patients were divided into four groups according to the period of preservation. There was no correlation between graft rejection, frequency of post-transplant dialysis, long term graft function and survival time, when the duration of preservation was less than 24 hours. The advantages of this technique included technical simplicity, low cost, minimal risk of graft infection and easy transportation. The two primary disadvantages were an apparent 24 to 30 hour limit of organ preservation with prompt function and the inability to determine intrarenal perfusion pressure during preservation, thereby missing an important parameter of graft viability.

  2. Low Frequency Stimulation Decreases Seizure Activity in a Mutation Model of Epilepsy

    PubMed Central

    Kile, Kara Buehrer; Tian, Nan; Durand, Dominique M.

    2013-01-01

    Summary Purpose To investigate brain electrical activity in Q54 mice that display spontaneous seizures because of a gain-of-function mutation of the Scn2a sodium channel gene, and to evaluate the efficacy of low frequency deep brain stimulation (DBS) for seizure frequency reduction. Methods EEG, EMG, and hippocampal deep electrodes were implanted into Q54 mice expressing an epileptic phenotype (n = 6). Chronic six channel recordings (wideband, 0.1–300 Hz) were stored 24 hours a day for more than 12 days. Low Frequency stimulation (LFS) (3Hz, square wave, biphasic, 100μs, 400μA) was applied to the ventral hippocampal commisure (VHC) in alternating five minute cycles (on or off) 24 hours a day for a period of four days. Results LFS (3Hz) resulted in a significant reduction in seizure frequency and duration (21% and 35%, p<0.05), when applied to the VHC of epileptic Q54 mice (n = 6). Seizure frequency was not directly affected by stimulation state (“on” versus “off”). Conclusion LFS applied at a frequency of 3Hz significantly reduced seizure frequency and duration in the Q54 model. Furthermore, the reduction of seizure frequency and duration by LFS was not immediate but had a delayed and lasting effect, supporting complex, indirect mechanisms of action. PMID:20659150

  3. Frequency-risk and duration-risk relations between second-hand smoke exposure and menopausal symptoms among middle-aged women in Guangzhou, China.

    PubMed

    Ye, X; Yao, Z; Xu, Y; Zhou, S; Gao, Y; Chen, S; Yang, Y

    2015-04-01

    Tobacco smoking and menopausal symptoms are strongly associated, but the possible effects of second-hand smoke (SHS) have not been evaluated. This study aimed to explore the possible frequency-risk and duration-risk relations between SHS exposure and menopausal symptoms among non-smoking, middle-aged women. A cross-sectional survey was conducted in Guangzhou, China using a stratified three-stage sampling method. Menopausal symptoms were measured by the modified Kupperman Index with a cut-off point of 7. The frequency-risk and duration-risk relations between SHS exposure and menopausal symptoms were examined using logistic regression models. Compared with non-exposure, SHS exposure was associated with increased menopausal symptoms (odds ratio (OR) = 1.69, 95% confidence interval (CI) 1.22-2.33 for exposure in any of the venues). The trend analysis showed that there were frequency-risk (OR = 1.43 for occasional exposure; OR = 2.30 for regular exposure; p for linear trend < 0.001) and duration-risk (OR = 1.09 for 1-15 years; OR = 1.99 for > 15 years; p for linear trend < 0.001) relations. When examining the frequency-risk and duration-risk relations by source of exposure (in homes or in workplaces), there was still evidence of increasing trend for risk of menopausal symptoms. Findings from the present study suggest that SHS exposure is positively associated with menopausal symptoms in middle-aged women in a dose-response manner and highlight the need for further research to establish the mechanisms of the association.

  4. Regionalization of precipitation characteristics in Montana using L-moments

    USGS Publications Warehouse

    Parrett, C.

    1998-01-01

    Dimensionless precipitation-frequency curves for estimating precipitation depths having small exceedance probabilities were developed for 2-, 6-, and 24-hour storm durations for three homogeneous regions in Montana. L-moment statistics were used to help define the homogeneous regions. The generalized extreme value distribution was used to construct the frequency curves for each duration within each region. The effective record length for each duration in each region was estimated using a graphical method and was found to range from 500 years for 6-hour duration data in Region 2 to 5,100 years for 24-hour duration data in Region 3. The temporal characteristics of storms were analyzed, and methods for estimating synthetic storm hyetographs were developed. Dimensionless depth-duration data were grouped by independent duration (2,6, and 24 hours) and by region, and the beta distribution was fit to dimensionless depth data for various incremental time intervals. Ordinary least-squares regression was used to develop relations between dimensionless depths for a key, short duration - termed the kernel duration - and dimensionless depths for other durations. The regression relations were used, together with the probabilistic dimensionless depth data for the kernel duration, to calculate dimensionless depth-duration curves for exceedance probabilities from .1 to .9. Dimensionless storm hyetographs for each independent duration in each region were constructed for median value conditions based on an exceedance probability of .5.

  5. Time-frequency dynamics during sleep spindles on the EEG in rodents with a genetic predisposition to absence epilepsy (WAG/Rij rats)

    NASA Astrophysics Data System (ADS)

    Hramov, Alexander E.; Sitnikova, Evgenija Y.; Pavlov, Alexey N.; Grubov, Vadim V.; Koronovskii, Alexey A.; Khramova, Marina V.

    2015-03-01

    Sleep spindles are known to appear spontaneously in the thalamocortical neuronal network of the brain during slow-wave sleep; pathological processes in the thalamocortical network may be the reason of the absence epilepsy. The aim of the present work is to study developed changes in the time-frequency structure of sleep spindles during the progressive development of the absence epilepsy in WAG/Rij rats. EEG recordings were made at age 7 and 9 months. Automatic recognition and subsequent analysis of sleep spindles on the EEG were performed using the continuous wavelet transform. The duration of epileptic discharges and the total duration of epileptic activity were found to increase with age, while the duration of sleep spindles, conversely, decreased. In terms of the mean frequency, sleep spindles could be divided into three classes: `slow' (mean frequency 9.3Hz), `medium' (11.4Hz), and `fast' (13.5Hz). Slow and medium (transitional) spindles in five-month-old animals showed increased frequency from the beginning to the end of the spindle. The more intense the epilepsy is, the shorter are the durations of spindles of all types. The mean frequencies of `medium' and `fast' spindles were higher in rats with more intense signs of epilepsy. Overall, high epileptic activity in WAG/Rij rats was linked with significant changes in spindles of the transitional type, with less marked changes in the two traditionally identified types of spindle, slow and fast.

  6. Retrospective comparison of voglibose or acarbose as an add-on therapy to sulfonylureas in Western Indian patients with uncontrolled overweight/obese type 2 diabetes.

    PubMed

    Talaviya, Praful A; Saboo, Banshi D; Dodiya, Hardik G; Rao, Shaival K; Joshi, Shashank R; Modh, Vipul B; Ghadiya, Sneha V

    2016-01-01

    The study was aimed to investigate the effect of voglibose or acarbose as an add-on treatment in overweight/obese type 2 diabetes (T2DM) patients who are uncontrolled with metformin and sulfonylureas (SUs) in Western part of India. A retrospective study included 77 participants (BMI≥25kg/m(2); HbA1c level>8% and<9.5%) with overweight/obese T2DM. These participants were treated with either voglibose or acarbose. Glycemic parameters (fasting blood glucose and glycated hemoglobin [HbA1c]), bodyweight, BMI and lipid parameters were evaluated at baseline, 3-month, 6-month and 9-month of treatment. Adverse events were also captured at respective time points. Voglibose showed significant reduction in HbA1c and bodyweight with short duration of treatment (6 months; P<0.05 and 9 months; P<0.01) whereas acarbose showed significant reduction with longer duration of treatment (9 months; P<0.05) when compared with baseline. Moreover, both treatment groups were reported with reduction in BMI. Further, significant improvement in lipid parameters except LDL and HDL were observed in both treatment groups when compared with baseline. None of participant was discontinued due to side effects of the treatment. In addition, the frequency of hypoglycemia was decreased in both treatment groups. Voglibose or acarbose as an add-on treatment with metformin and sulfonylureas in uncontrolled obese/overweight T2DM provides desired glycemic control, reduces bodyweight and improves lipid parameters with good tolerability profile. Copyright © 2015 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  7. Eruptive Source Parameters from Near-Source Gravity Waves Induced by Large Vulcanian eruptions

    NASA Astrophysics Data System (ADS)

    Barfucci, Giulia; Ripepe, Maurizio; De Angelis, Silvio; Lacanna, Giorgio; Marchetti, Emanuele

    2016-04-01

    The sudden ejection of hot material from volcanic vent perturbs the atmosphere generating a broad spectrum of pressure oscillations from acoustic infrasound (<10 Hz) to gravity waves (<0.03 Hz). However observations of gravity waves excited by volcanic eruptions are still rare, mostly limited to large sub-plinian eruptions and frequently at large distance from the source (>100 km). Atmospheric Gravity waves are induced by perturbations of the hydrostatic equilibrium of the atmosphere and propagate within a medium with internal density stratification. They are initiated by mechanisms that cause the atmosphere to be displaced as for the injection of volcanic ash plume during an eruption. We use gravity waves to infer eruptive source parameters, such as mass eruption rate (MER) and duration of the eruption, which may be used as inputs in the volcanic ash transport and dispersion models. We present the analysis of near-field observations (<7 km) of atmospheric gravity waves, with frequencies of 0.97 and 1.15 mHz, recorded by a pressure sensors network during two explosions in July and December 2008 at Soufrière Hills Volcano, Montserrat. We show that gravity waves at Soufrière Hills Volcano originate above the volcanic dome and propagate with an apparent horizontal velocities of 8-10 m/s. Assuming a single mass injection point source model, we constrain the source location at ~3.5 km a.s.l., above the vent, duration of the gas thrust < 140 s and MERs of 2.6 and 5.4 x10E7 kg/s, for the two eruptive events. Source duration and MER derived by modeling Gravity Waves are fully compatible with others independent estimates from field observations. Our work strongly supports the use of gravity waves to model eruption source parameters and can have a strong impact on our ability to monitor volcanic eruption at a large distance and may have future application in assessing the relative magnitude of volcanic explosions.

  8. Exploring Communication and Course Format: Conversation Frequency and Duration, Student Motives, and Perceived Teacher Approachability for Out-of-Class Contact

    ERIC Educational Resources Information Center

    Brooks, Catherine F.; Young, Stacy L.

    2016-01-01

    This study explored how course instructional format (i.e., online, face-to-face, or hybrid) is related to the frequency and duration of out-of-class communication (OCC) between college instructors and students, to student motives for communicating with teachers, and to perceived teacher approachability for conversation outside of class. Though…

  9. Mentoring and Other Adult Involvement with Juveniles in Treatment: Do They Decrease the Probability of Elopement?

    ERIC Educational Resources Information Center

    Burford, Michael L.; Nugent, William R.; Wodarski, John

    2005-01-01

    This paper focuses on whether running away from adolescent residential care facilities is related to having off grounds passes with an adult resource. It was hypothesized that as off grounds passes increased in frequency and duration, runaway behavior would decrease in frequency and duration. Data were collected from two hundred closed client…

  10. A new method to calculate the beam charge for an integrating current transformer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu Yuchi; Han Dan; Zhu Bin

    2012-09-15

    The integrating current transformer (ICT) is a magnetic sensor widely used to precisely measure the charge of an ultra-short-pulse charged particle beam generated by traditional accelerators and new laser-plasma particle accelerators. In this paper, we present a new method to calculate the beam charge in an ICT based on circuit analysis. The output transfer function shows an invariable signal profile for an ultra-short electron bunch, so the function can be used to evaluate the signal quality and calculate the beam charge through signal fitting. We obtain a set of parameters in the output function from a standard signal generated bymore » an ultra-short electron bunch (about 1 ps in duration) at a radio frequency linear electron accelerator at Tsinghua University. These parameters can be used to obtain the beam charge by signal fitting with excellent accuracy.« less

  11. Detection of tiny amounts of fissile materials in large-sized containers with radioactive waste

    NASA Astrophysics Data System (ADS)

    Batyaev, V. F.; Skliarov, S. V.

    2018-01-01

    The paper is devoted to non-destructive control of tiny amounts of fissile materials in large-sized containers filled with radioactive waste (RAW). The aim of this work is to model an active neutron interrogation facility for detection of fissile ma-terials inside NZK type containers with RAW and determine the minimal detectable mass of U-235 as a function of various param-eters: matrix type, nonuniformity of container filling, neutron gen-erator parameters (flux, pulse frequency, pulse duration), meas-urement time. As a result the dependence of minimal detectable mass on fissile materials location inside container is shown. Nonu-niformity of the thermal neutron flux inside a container is the main reason of the space-heterogeneity of minimal detectable mass in-side a large-sized container. Our experiments with tiny amounts of uranium-235 (<1 g) confirm the detection of fissile materials in NZK containers by using active neutron interrogation technique.

  12. Self-reported mobile phone use and semen parameters among men from a fertility clinic.

    PubMed

    Lewis, Ryan C; Mínguez-Alarcón, Lidia; Meeker, John D; Williams, Paige L; Mezei, Gabor; Ford, Jennifer B; Hauser, Russ

    2017-01-01

    There is increasing concern that use of mobile phones, a source of low-level radio-frequency electromagnetic fields, may be associated with poor semen quality, but the epidemiologic evidence is limited and conflicting. The relationship between mobile phone use patterns and markers of semen quality was explored in a longitudinal cohort study of 153 men that attended an academic fertility clinic in Boston, Massachusetts. Information on mobile phone use duration, headset or earpiece use, and the body location in which the mobile phone was carried was ascertained via nurse-administered questionnaire. Semen samples (n=350) were collected and analyzed onsite. To account for multiple semen samples per man, linear mixed models with random intercepts were used to investigate the association between mobile phone use and semen parameters. Overall, there was no evidence for a relationship between mobile phone use and semen quality. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Geographical variation in sound production in the anemonefish Amphiprion akallopisos

    PubMed Central

    Parmentier, E; Lagardère, J.P; Vandewalle, P; Fine, M.L

    2005-01-01

    Because of pelagic-larval dispersal, coral-reef fishes are distributed widely with minimal genetic differentiation between populations. Amphiprion akallopisos, a clownfish that uses sound production to defend its anemone territory, has a wide but disjunct distribution in the Indian Ocean. We compared sounds produced by these fishes from populations in Madagascar and Indonesia, a distance of 6500 km. Differentiation of agonistic calls into distinct types indicates a complexity not previously recorded in fishes' acoustic communication. Moreover, various acoustic parameters, including peak frequency, pulse duration, number of peaks per pulse, differed between the two populations. The geographic comparison is the first to demonstrate ‘dialects’ in a marine fish species, and these differences in sound parameters suggest genetic divergence between these two populations. These results highlight the possible approach for investigating the role of sounds in fish behaviour in reproductive divergence and speciation. PMID:16087425

  14. Self-reported mobile phone use and semen parameters among men from a fertility clinic

    PubMed Central

    Lewis, Ryan C.; Mínguez-Alarcón, Lidia; Meeker, John D.; Williams, Paige L.; Mezei, Gabor; Ford, Jennifer B.; Hauser, Russ

    2017-01-01

    There is increasing concern that use of mobile phones, a source of low-level radio-frequency electromagnetic fields, may be associated with poor semen quality, but the epidemiologic evidence is limited and conflicting. The relationship between mobile phone use patterns and markers of semen quality was explored in a longitudinal cohort study of 153 men that attended an academic fertility clinic in Boston, Massachusetts. Information on mobile phone use duration, headset or earpiece use, and the body location in which the mobile phone was carried was ascertained via nurse-administered questionnaire. Semen samples (n=350) were collected and analyzed onsite. To account for multiple semen samples per man, linear mixed models with random intercepts were used to investigate the association between mobile phone use and semen parameters. Overall, there was no evidence for a relationship between mobile phone use and semen quality. PMID:27838386

  15. Method of detecting system function by measuring frequency response

    DOEpatents

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.; Motloch, Chester G.

    2013-01-08

    Methods of rapidly measuring an impedance spectrum of an energy storage device in-situ over a limited number of logarithmically distributed frequencies are described. An energy storage device is excited with a known input signal, and a response is measured to ascertain the impedance spectrum. An excitation signal is a limited time duration sum-of-sines consisting of a select number of frequencies. In one embodiment, magnitude and phase of each frequency of interest within the sum-of-sines is identified when the selected frequencies and sample rate are logarithmic integer steps greater than two. This technique requires a measurement with a duration of one period of the lowest frequency. In another embodiment, where selected frequencies are distributed in octave steps, the impedance spectrum can be determined using a captured time record that is reduced to a half-period of the lowest frequency.

  16. Modeling the effect of sedentary behaviour on the prevention of population obesity using the system dynamics approach

    NASA Astrophysics Data System (ADS)

    Abidin, Norhaslinda Zainal; Zaibidi, Nerda Zura; Zulkepli, Jafri Hj

    2015-10-01

    Obesity is a medical condition where an individual has an excessive amount of body fat. There are many factors contributing to obesity and one of them is the sedentary behaviour. Rapid development in industrialization and urbanization has brought changes to Malaysia's socioeconomic, especially the lifestyles of Malaysians. With this lifestyle transition, one of the impact is on weight and obesity. How does sedentary behaviour have an impact on the growth of Malaysian population's weight and obesity? What is the most effective sedentary behaviour preventing strategy to obesity? Is it through reduction in duration or frequency of sedentary behaviour? Thus, the aim of this paper is to design an intervention to analyse the effect of decreasing duration and frequency of sedentary behaviour on the population reversion trends of average weight (AW), average body mass index (ABMI), and prevalence of overweight and obesity (POVB). This study combines the different strands of sub-models comprised of nutrition, physical activity and body metabolism, and then synthesis these knowledge into a system dynamics of weight behaviour model, namely SIMULObese. Findings from this study revealed that Malaysian's adults spend a lot of time engaged in sedentary behaviour and this resulted in weight gain and obesity. Comparing between frequency and duration of sedentary behaviour, this study reported that reduced in duration or time spend in sedentary behaviour is a better preventing strategy to obesity compared to duration. As a summary, this study highlighted the importance of decreasing the frequency and duration of sedentary behaviour in developing guidelines to prevent obesity.

  17. Fast vigilance decrement in closed head injury patients as reflected by the mismatch negativity (MMN).

    PubMed

    Kaipio, M L; Novitski, N; Tervaniemi, M; Alho, K; Ohman, J; Salonen, O; Näätänen, R

    2001-05-25

    Event-related potentials (ERPs) were measured from 24 chronic closed head injury (CHI) patients and 18 age- and education-matched controls. The oddball paradigm was applied while subjects were watching a silent movie. The standard (p=0.8) sound of 75 ms duration had a basic frequency of 500 Hz with harmonic partials of 1000 Hz and 1500 Hz, whereas these frequencies for the pitch deviant were each 10% higher. The frequencies of the duration deviant matched with those of the standard but was 25 ms in duration. The MMN (mismatch negativity), generated by the brain's automatic auditory change-detector mechanism, was elicited by both deviants. No significant differences in the MMN latency or amplitude for either pitch or duration deviants were found between the groups. However, the MMN amplitude for the pitch deviant decreased in the patient group during the experiment considerably faster than in controls, suggesting a faster vigilance decrement in the patients.

  18. High-frequency ultrasound evaluation of cellulite treated with the 1064 nm Nd:YAG laser.

    PubMed

    Bousquet-Rouaud, Regine; Bazan, Marie; Chaintreuil, Jean; Echague, Agustina Vila

    2009-03-01

    To investigate non-invasive laser treatment for cellulite using the 1064 nm Nd:YAG laser and to correlate clinical results with high-frequency skin ultrasound images. Twelve individuals of normal weight were treated on either the left or right posterior side of the thigh with the following parameters: fluence 30 J/cm, 18 mm spot size and dynamic cooling device pulse duration of 30 ms. Three treatments were performed at intervals of 3-4 weeks, and followed-up 1 and 3 months after the last session. Photographs and ultrasound imaging were assessed before each session. The 1064 nm Nd:YAG laser resulted in a tightening of the skin and an improvement in cellulite. No side effects were reported. High-resolution ultrasound imaging showed a significant improvement in dermis density and a reduction of dermis thickness. The method is described in detail in Appendix 1. Infra-red lasers may constitute a safe and effective treatment for cellulite and high-frequency ultrasound imaging provides a quantitative and objective measurement of the treatment efficacy.

  19. Biochemical Frequency Control by Synchronisation of Coupled Repressilators: An In Silico Study of Modules for Circadian Clock Systems

    PubMed Central

    Hinze, Thomas; Schumann, Mathias; Bodenstein, Christian; Heiland, Ines; Schuster, Stefan

    2011-01-01

    Exploration of chronobiological systems emerges as a growing research field within bioinformatics focusing on various applications in medicine, agriculture, and material sciences. From a systems biological perspective, the question arises whether biological control systems for regulation of oscillatory signals and their technical counterparts utilise similar mechanisms. If so, modelling approaches and parameterisation adopted from building blocks can help to identify general components for frequency control in circadian clocks along with gaining insight into mechanisms of clock synchronisation to external stimuli like the daily rhythm of sunlight and darkness. Phase-locked loops could be an interesting candidate in this context. Both, biology and engineering, can benefit from a unified view resulting from systems modularisation. In a first experimental study, we analyse a model of coupled repressilators. We demonstrate its ability to synchronise clock signals in a monofrequential manner. Several oscillators initially deviate in phase difference and frequency with respect to explicit reaction and diffusion rates. Accordingly, the duration of the synchronisation process depends on dedicated reaction and diffusion parameters whose settings still lack to be sufficiently captured analytically. PMID:22046179

  20. [EFFECTS OF WHOLE-BODY VIBRATION TRAINING ON BODY COMPOSITION AND PHYSICAL FITNESS IN RECREATIONALLY ACTIVE YOUNG ADULTS].

    PubMed

    Martínez-Pardo, Esmeraldo; Martínez-Ruiz, Enrique; Alcaraz, Pedro E; Rubio-Arias, Jacobo A

    2015-11-01

    In the last decade, it has been suggested that whole- body vibration training (WBV) may increase neuromuscular performance and consequently affect the muscular improvement as either acute response to vibration or chronic adaptation training. Vibrating platforms generate frequencies from 5-45 Hz and vertical oscillations of 1-11 mm peak to peak, affecting more or less intensity acceleration changing by combining frequency and amplitude. Vibration training, in a session as various offers different results in regard to changes in body composition and in increasing the vertical jump, sprint, and the different manifestations of force development. These promising results await further research to establish parameters (duration, frequency and amplitude) with vibration stimulation in young active subjects. This literature review provides an update on the scientific evidence on the body vibrations in order to answer the question whether WBV, meaning the exercise by increasing the gravitational load collection, is a treatment option if the aim is to improve neuromuscular function, flexibility, balance, agility, coordination and body composition. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  1. Formation of laser-induced periodic surface structures on niobium by femtosecond laser irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, A.; Dias, A.; Gomez-Aranzadi, M.

    2014-05-07

    The surface morphology of a Niobium sample, irradiated in air by a femtosecond laser with a wavelength of 800 nm and pulse duration of 100 fs, was examined. The period of the micro/nanostructures, parallel and perpendicularly oriented to the linearly polarized fs-laser beam, was studied by means of 2D Fast Fourier Transform analysis. The observed Laser-Induced Periodic Surface Structures (LIPSS) were classified as Low Spatial Frequency LIPSS (periods about 600 nm) and High Spatial Frequency LIPSS, showing a periodicity around 300 nm, both of them perpendicularly oriented to the polarization of the incident laser wave. Moreover, parallel high spatial frequency LIPSS were observedmore » with periods around 100 nm located at the peripheral areas of the laser fingerprint and overwritten on the perpendicular periodic gratings. The results indicate that this method of micro/nanostructuring allows controlling the Niobium grating period by the number of pulses applied, so the scan speed and not the fluence is the key parameter of control. A discussion on the mechanism of the surface topology evolution was also introduced.« less

  2. Variation of Static-PPP Positioning Accuracy Using GPS-Single Frequency Observations (Aswan, Egypt)

    NASA Astrophysics Data System (ADS)

    Farah, Ashraf

    2017-06-01

    Precise Point Positioning (PPP) is a technique used for position computation with a high accuracy using only one GNSS receiver. It depends on highly accurate satellite position and clock data rather than broadcast ephemeries. PPP precision varies based on positioning technique (static or kinematic), observations type (single or dual frequency) and the duration of collected observations. PPP-(dual frequency receivers) offers comparable accuracy to differential GPS. PPP-single frequency receivers has many applications such as infrastructure, hydrography and precision agriculture. PPP using low cost GPS single-frequency receivers is an area of great interest for millions of users in developing countries such as Egypt. This research presents a study for the variability of single frequency static GPS-PPP precision based on different observation durations.

  3. Damage characterization on human femur bone by means of ultrasonics and acoustic emission

    NASA Astrophysics Data System (ADS)

    Strantza, M.; Polyzos, D.; Louis, O.; Boulpaep, F.; Van Hemelrijck, D.; Aggelis, D. G.

    2015-07-01

    Human bone tissue is characterized as a material with high brittleness. Due to this nature, visible signs of cracking are not easy to be detected before final failure. The main objective of this work is to investigate if the acoustic emission (AE) technique can offer valuable insight to the fracture process of human femur specimens as in other engineering materials characterization. This study describes the AE activity during fracture of whole femur bones under flexural load. Before fracture, broadband AE sensors were used in order to measure parameters like wave velocity dispersion and attenuation. Waveform parameters like the duration, rise time and average frequency, were also examined relatively to the propagation distance as a preparation for the AE monitoring during fracture. After the ultrasonic study, the samples were partly cast in concrete and fixed as cantilevers. A point load was applied on the femur head, which due to the test geometry resulted in a combination of two different patterns of fracture, bending and torsion. Two AE broadband sensors were placed in different points of the sample, one near the fixing end and the other near the femur head. Preliminary analysis shows that parameters like the number of acquired AE signals and their amplitude are well correlated with the load history. Furthermore, the parameters of rise time and frequency can differentiate the two fracture patterns. Additionally, AE allows the detection of the load at the onset of fracture from the micro-cracking events that occur at the early loading stages, allowing monitoring of the whole fracture process. Parameters that have been used extensively for monitoring and characterization of fracture modes of engineering materials seem to poses characterization power in the case of bone tissue monitoring as well.

  4. Long-period long-duration seismic events during hydraulic fracturing: Implications for tensile fracture development

    NASA Astrophysics Data System (ADS)

    Hu, Hongru; Li, Aibing; Zavala-Torres, Ricardo

    2017-05-01

    Long-period long-duration (LPLD) seismic events are observed from a microseismic data set acquired by surface receivers in the Eagle Ford Shale. These events are characterized by low frequencies of 10-60 Hz and long durations of 30-60 s. The seismograms are dominated with P waves, and the frequency spectra have peaks at several isolated frequencies, similar to volcanic tremors. The LPLD events are located close to the horizontal hydraulic treatment well and migrate away from the well with time. These observations suggest that the LPLD events are related to hydraulic fracturing and are possibly caused by the jerky opening and resonance of fluid-filled cracks. Imaging this type of LPLD events can potentially map fluid flow and tensile fracture development during hydraulic fracturing.

  5. Risk of adverse health outcomes associated with frequency and duration of deployment with the Australian Defence Force.

    PubMed

    Bleier, Jonathan; McFarlane, Alexander; McGuire, Annabel; Treloar, Susan; Waller, Michael; Dobson, Annette

    2011-02-01

    The operational tempo of the Australian Defence Force has increased over the last two decades. We examine the relationship between health of personnel and the frequency and duration of their deployment. Self-reported health measures (number of symptoms, Kessler Psychological Distress Scale, and Post Traumatic Stress Disorder Checklist) were compared for people who had never deployed to those who had deployed only once and for those who had deployed at least twice with at least one deployment to East Timor and one deployment to Afghanistan or Iraq. Comparisons were also made between people who had deployed for at least one month and those who had deployed for longer periods. Frequency of deployment but not duration of deployment was associated with poorer health.

  6. Dissociable effects of inter-stimulus interval and presentation duration on rapid face categorization.

    PubMed

    Retter, Talia L; Jiang, Fang; Webster, Michael A; Rossion, Bruno

    2018-04-01

    Fast periodic visual stimulation combined with electroencephalography (FPVS-EEG) has unique sensitivity and objectivity in measuring rapid visual categorization processes. It constrains image processing time by presenting stimuli rapidly through brief stimulus presentation durations and short inter-stimulus intervals. However, the selective impact of these temporal parameters on visual categorization is largely unknown. Here, we presented natural images of objects at a rate of 10 or 20 per second (10 or 20 Hz), with faces appearing once per second (1 Hz), leading to two distinct frequency-tagged EEG responses. Twelve observers were tested with three squarewave image presentation conditions: 1) with an ISI, a traditional 50% duty cycle at 10 Hz (50-ms stimulus duration separated by a 50-ms ISI); 2) removing the ISI and matching the rate, a 100% duty cycle at 10 Hz (100-ms duration with 0-ms ISI); 3) removing the ISI and matching the stimulus presentation duration, a 100% duty cycle at 20 Hz (50-ms duration with 0-ms ISI). The face categorization response was significantly decreased in the 20 Hz 100% condition. The conditions at 10 Hz showed similar face-categorization responses, peaking maximally over the right occipito-temporal (ROT) cortex. However, the onset of the 10 Hz 100% response was delayed by about 20 ms over the ROT region relative to the 10 Hz 50% condition, likely due to immediate forward-masking by preceding images. Taken together, these results help to interpret how the FPVS-EEG paradigm sets temporal constraints on visual image categorization. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Perioperative Characteristics of Siblings Undergoing Liver or Kidney Transplant.

    PubMed

    Ersoy, Zeynep; Ozdemirkan, Aycan; Pirat, Arash; Torgay, Adnan; Arslan, Gulnaz; Haberal, Mehmet

    2015-11-01

    Reasons for chronic liver and kidney failure may vary; sometimes more than 1 family member may be affected, and may require a transplant. The aim of this study was to examine the similarities or differences between the perioperative characteristics of siblings undergoing liver or kidney transplant. The medical records of 6 pairs of siblings who underwent liver transplant and 4 pairs of siblings who underwent kidney transplant at Baskent University Hospital between 1989 and 2014 were retrospectively analyzed. Collected data included demographic features; comorbidities; reasons for liver and kidney failure; perioperative laboratory values; intraoperative hemodynamic parameters; use and volume of crystalloids, colloids, blood products, cell saver system, and albumin; duration of anesthesia; urine output; and postoperative follow-up data. The mean age of the 6 sibling pairs who underwent liver transplant was 16.3 ± 12.2 years. All 12 patients had Child-Pugh grade B cirrhosis, with mean disease duration of 7.8 ± 3.9 years. There were no significant differences between siblings with respect to intraoperative blood product transfusion, crystalloid and colloid fluid replacements, hypotension frequency, blood gas analyses, urinary output, duration of anhepatic phase, inotropic agent administration, postoperative laboratory values, need for mechanical ventilation and vasopressors, occurrence of acute renal failure and infections, and duration intensive care unit stay (P > .05). The mean age of the 4 sibling pairs who underwent kidney transplant was 21.3 ± 6.4 years, with mean duration of renal insufficiency of 2.2 ± 1.6 years. There were no significant differences between siblings with respect to intraoperative crystalloid and colloid fluid administration, duration of anesthesia, intraoperative mannitol and furosemide administration, and postoperative laboratory values (P > .05). In conclusion, the 6 sibling pairs who underwent liver transplant and 4 sibling pairs who underwent kidney transplant in our cohort had similar perioperative characteristics.

  8. Hearing threshold shifts and recovery after noise exposure in beluga whales, Delphinapterus leucas.

    PubMed

    Popov, Vladimir V; Supin, Alexander Ya; Rozhnov, Viatcheslav V; Nechaev, Dmitry I; Sysuyeva, Evgenia V; Klishin, Vladimir O; Pletenko, Mikhail G; Tarakanov, Mikhail B

    2013-05-01

    Temporary threshold shift (TTS) after loud noise exposure was investigated in a male and a female beluga whale (Delphinapterus leucas). The thresholds were evaluated using the evoked-potential technique, which allowed for threshold tracing with a resolution of ~1 min. The fatiguing noise had a 0.5 octave bandwidth, with center frequencies ranging from 11.2 to 90 kHz, a level of 165 dB re. 1 μPa and exposure durations from 1 to 30 min. The effects of the noise were tested at probe frequencies ranging from -0.5 to +1.5 octaves relative to the noise center frequency. The effect was estimated in terms of both immediate (1.5 min) post-exposure TTS and recovery duration. The highest TTS with the longest recovery duration was produced by noises of lower frequencies (11.2 and 22.5 kHz) and appeared at a test frequency of +0.5 octave. At higher noise frequencies (45 and 90 kHz), the TTS decreased. The TTS effect gradually increased with prolonged exposures ranging from 1 to 30 min. There was a considerable TTS difference between the two subjects.

  9. Effect of wet curing duration on durability parameters of hydraulic cement concretes.

    DOT National Transportation Integrated Search

    2010-01-01

    Hydraulic cement concrete slabs were cast and stored outdoors in Charlottesville, Virginia, to study the impact of wet curing duration on durability parameters. Concrete mixtures were produced using portland cement, portland cement with slag cement, ...

  10. Impact of exposure time, particle size and uptake pathway on silver nanoparticle effects on circulating immune cells in mytilus galloprovincialis.

    PubMed

    Bouallegui, Younes; Ben Younes, Ridha; Turki, Faten; Oueslati, Ridha

    2017-12-01

    Nanomaterials have increasingly emerged as potential pollutants to aquatic organisms. Nanomaterials are known to be taken up by hemocytes of marine invertebrates including Mytilus galloprovincialis. Indeed, assessments of hemocyte-related parameters are a valuable tool in the determination of potentials for nanoparticle (NP) toxicity. The present study assessed the effects from two size types of silver nanoparticles (AgNP: <50 nm and <100 nm) on the frequency of hemocytes subpopulations as immunomodulation biomarkers exposed in a mollusk host. Studies were performed using exposures prior to and after inhibition of potential NP uptake pathways (i.e. clathrin- and caveolae-mediated endocytosis) and over different durations of exposure (3, 6 and 12 h). Differential hemocyte counts (DHC) revealed significant variations in frequency of different immune cells in mussels exposed for 3 hr to either AgNP size. However, as exposure duration progressed cell levels were subsequently differentially altered depending on particle size (i.e. no significant effects after 3 h with larger AgNP). AgNP effects were also delayed/varied after blockade of either clathrin- or caveolae-mediated endocytosis. The results also noted significant negative correlations between changes in levels hyalinocytes and acidophils or in levels basophils and acidophils as a result of AgNP exposure. From these results, we concluded AgNP effects on mussels were size and duration of exposure dependent. This study highlighted how not only was NP size important, but that differing internalization mechanisms could be key factors impacting on the potential for NP in the environment to induce immunomodulation in a model/test sentinel host like M. galloprovincialis.

  11. Biomechanical properties of low back myofascial tissue in younger adult ankylosing spondylitis patients and matched healthy control subjects.

    PubMed

    White, Allison; Abbott, Hannah; Masi, Alfonse T; Henderson, Jacqueline; Nair, Kalyani

    2018-06-06

    Ankylosing spondylitis is a degenerative and inflammatory rheumatologic disorder that primarily affects the spine. Delayed diagnosis leads to debilitating spinal damage. This study examines biomechanical properties of non-contracting (resting) human lower lumbar myofascia in ankylosing spondylitis patients and matched healthy control subjects. Biomechanical properties of stiffness, frequency, decrement, stress relaxation time, and creep were quantified from 24 ankylosing spondylitis patients (19 male, 5 female) and 24 age- and sex-matched control subjects in prone position on both sides initially and after 10 min rest. Concurrent surface electromyography measurements were performed to ensure resting state. Statistical analyses were conducted, and significance was set at p < 0.05. Decreased lumbar muscle elasticity (inverse of decrement) was primarily correlated with disease duration in ankylosing spondylitis subjects, whereas BMI was the primary correlate in control subjects. In ankylosing spondylitis and control groups, significant positive correlations were observed between the linear elastic properties of stiffness and frequency as well as between the viscoelastic parameters of stress relaxation time and creep. The preceding groups also showed significant negative correlations between the linear elastic and viscoelastic properties. Findings indicate that increased disease duration is associated with decreased tissue elasticity or myofascial degradation. Both ankylosing spondylitis and healthy subjects revealed similar correlations between the linear and viscoelastic properties which suggest that the disease does not directly alter their inherent interrelations. The novel results that stiffness is greater in AS than normal subjects, whereas decrement is significantly correlated with AS disease duration deserves further investigation of the biomechanical properties and their underlying mechanisms. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Ethosuximide and Phenytoin Dose-Dependently Attenuate Acute Nonconvulsive Seizures after Traumatic Brain Injury in Rats

    PubMed Central

    Shear, Deborah A.; Potter, Brittney; Marcsisin, Sean R.; Sousa, Jason; Melendez, Victor; Tortella, Frank C.; Lu, Xi-Chun M.

    2013-01-01

    Abstract Acute seizures frequently occur following severe traumatic brain injury (TBI) and have been associated with poor patient prognosis. Silent or nonconvulsive seizures (NCS) manifest in the absence of motor convulsion, can only be detected via continuous electroencephalographic (EEG) recordings, and are often unidentified and untreated. Identification of effective anti-epileptic drugs (AED) against post-traumatic NCS remains crucial to improve neurological outcome. Here, we assessed the anti-seizure profile of ethosuximide (ETX, 12.5–187.5 mg/kg) and phenytoin (PHT, 5–30 mg/kg) in a spontaneously occurring NCS model associated with penetrating ballistic-like brain injury (PBBI). Rats were divided between two drug cohorts, PHT or ETX, and randomly assigned to one of four doses or vehicle within each cohort. Following PBBI, NCS were detected by continuous EEG monitoring for 72 h post-injury. Drug efficacy was evaluated on NCS parameters of incidence, frequency, episode duration, total duration, and onset latency. Both PHT and ETX attenuated NCS in a dose-dependent manner. In vehicle-treated animals, 69–73% experienced NCS (averaging 9–10 episodes/rat) with average onset of NCS occurring at 30 h post-injury. Compared with control treatment, the two highest PHT and ETX doses significantly reduced NCS incidence to 13–40%, reduced NCS frequency (1.8–6.2 episodes/rat), and delayed seizure onset: <20% of treated animals exhibited NCS within the first 48 h. NCS durations were also dose-dependently mitigated. For the first time, we demonstrate that ETX and PHT are effective against spontaneously occurring NCS following PBBI, and suggest that these AEDs may be effective at treating post-traumatic NCS. PMID:23822888

  13. The role of subjective frequency in language switching: An ERP investigation using masked priming

    PubMed Central

    Chauncey, Krysta; Grainger, Jonathan; Holcomb, Phillip J.

    2012-01-01

    Two experiments examined the nature of language-switching effects in a priming paradigm with event-related brain potential (ERP) recordings. primes and targets were always unrelated words but could be either from the same or different languages (Experiment 1) or from the same or a different frequency range (Experiment 2). Effects of switching language across prime and target differed as a function of the direction of the switch and prime duration in Experiment 1. Effects tended to be stronger with 100-ms prime durations than with 50-ms durations, and the expected pattern of greater negativity in the switch condition appeared earlier when primes were in L1 and targets in L2 than vice versa. Experiment 2 examined whether these language-switching effects could be due to differences in the subjective frequency of words in a bilingual’s two languages, by testing a frequency-switching manipulation within the L1. Effects of frequency switching were evident in the ERP waveforms, but the pattern did not resemble the language-switching effects, therefore suggesting that different mechanisms are at play. PMID:21264577

  14. Isolating spectral cues in amplitude and quasi-frequency modulation discrimination by reducing stimulus duration.

    PubMed

    Borucki, Ewa; Berg, Bruce G

    2017-05-01

    This study investigated the psychophysical effects of distortion products in a listening task traditionally used to estimate the bandwidth of phase sensitivity. For a 2000 Hz carrier, estimates of modulation depth necessary to discriminate amplitude modulated (AM) tones and quasi-frequency modulated (QFM) were measured in a two interval forced choice task as a function modulation frequency. Temporal modulation transfer functions were often non-monotonic at modulation frequencies above 300 Hz. This was likely to be due to a spectral cue arising from the interaction of auditory distortion products and the lower sideband of the stimulus complex. When the stimulus duration was decreased from 200 ms to 20 ms, thresholds for low-frequency modulators rose to near-chance levels, whereas thresholds in the region of non-monotonicities were less affected. The decrease in stimulus duration appears to hinder the listener's ability to use temporal cues in order to discriminate between AM and QFM, whereas spectral information derived from distortion product cues appears more resilient. Copyright © 2017. Published by Elsevier B.V.

  15. The Fourier analysis applied to the relationship between (7)Be activity in the Serbian atmosphere and meteorological parameters.

    PubMed

    Rajačić, M M; Todorović, D J; Krneta Nikolić, J D; Janković, M M; Djurdjević, V S

    2016-09-01

    Air sample monitoring in Serbia, Belgrade started in the 1960s, while (7)Be activity in air and total (dry and wet) deposition has been monitored for the last 22 years by the Environment and Radiation Protection Department of the Institute for Nuclear Sciences, Vinca. Using this data collection, the changes of the (7)Be activity in the air and the total (wet and dry) deposition samples, as well as their correlation with meteorological parameters (temperature, pressure, cloudiness, sunshine duration, precipitation and humidity) that affect (7)Be concentration in the atmosphere, were mathematically described using the Fourier analysis. Fourier analysis confirmed the expected; the frequency with the largest intensity in the harmonic spectra of the (7)Be activity corresponds to a period of 1 year, the same as the largest intensity frequency in Fourier series of meteorological parameters. To analyze the quality of the results produced by the Fourier analysis, we compared the measured values of the parameters with the values calculated according to the Fourier series. Absolute deviations between measured and predicted mean monthly values are in range from 0.02 mBq/m(3) to 0.7 mBq/m(3) for (7)Be activity in air, and 0.01 Bq/m(2) and 0.6 Bq/m(2) for (7)Be activity in deposition samples. Relatively good agreement of measured and predicted results offers the possibility of prediction of the (7)Be activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Virtual reality applications for motor rehabilitation after stroke.

    PubMed

    Sisto, Sue Ann; Forrest, Gail F; Glendinning, Diana

    2002-01-01

    Hemiparesis is the primary physical impairment underlying functional disability after stroke. A goal of rehabilitation is to enhance motor skill acquisition, which is a direct result of practice. However, frequency and duration of practice are limited in rehabilitation. Virtual reality (VR) is a computer technology that simulates real-life learning while providing augmented feedback and increased frequency, duration, and intensity of practiced tasks. The rate and extent of relearning of motor tasks could affect the duration, effectiveness, and cost of patient care. The purpose of this article is to review the use of VR training for motor rehabilitation after stroke.

  17. Acoustic emission signatures of damage modes in concrete

    NASA Astrophysics Data System (ADS)

    Aggelis, D. G.; Mpalaskas, A. C.; Matikas, T. E.; Van Hemelrijck, D.

    2014-03-01

    The characterization of the dominant fracture mode may assist in the prediction of the remaining life of a concrete structure due to the sequence between successive tensile and shear mechanisms. Acoustic emission sensors record the elastic responses after any fracture event converting them into electric waveforms. The characteristics of the waveforms vary according to the movement of the crack tips, enabling characterization of the original mode. In this study fracture experiments on concrete beams are conducted. The aim is to examine the typical acoustic signals emitted by different fracture modes (namely tension due to bending and shear) in a concrete matrix. This is an advancement of a recent study focusing on smaller scale mortar and marble specimens. The dominant stress field and ultimate fracture mode is controlled by modification of the four-point bending setup while acoustic emission is monitored by six sensors at fixed locations. Conclusions about how to distinguish the sources based on waveform parameters of time domain (duration, rise time) and frequency are drawn. Specifically, emissions during the shear loading exhibit lower frequencies and longer duration than tensile. Results show that, combination of AE features may help to characterize the shift between dominant fracture modes and contribute to the structural health monitoring of concrete. This offers the basis for in-situ application provided that the distortion of the signal due to heterogeneous wave path is accounted for.

  18. Differences in phonetic discrimination stem from differences in psychoacoustic abilities in learning the sounds of a second language: Evidence from ERP research

    PubMed Central

    Mo, Lei

    2017-01-01

    The scientific community has been divided as to the origin of individual differences in perceiving the sounds of a second language (L2). There are two alternative explanations: a general psychoacoustic origin vs. a speech-specific one. A previous study showed that such individual variability is linked to the perceivers’ speech-specific capabilities, rather than the perceivers’ psychoacoustic abilities. However, we assume that the selection of participants and parameters of sound stimuli might not appropriate. Therefore, we adjusted the sound stimuli and recorded event-related potentials (ERPs) from two groups of early, proficient Cantonese (L1)-Mandarin (L2) bilinguals who differed in their mastery of the Mandarin (L2) phonetic contrast /in-ing/, to explore whether the individual differences in perceiving L2 stem from participants’ ability to discriminate various pure tones (frequency, duration and pattern). To precisely measure the participants’ acoustic discrimination, mismatch negativity (MMN) elicited by the oddball paradigm was recorded in the experiment. The results showed that significant differences between good perceivers (GPs) and poor perceivers (PPs) were found in the three general acoustic conditions (frequency, duration and pattern), and the MMN amplitude for GP was significantly larger than for PP. Therefore, our results support a general psychoacoustic origin of individual variability in L2 phonetic mastery. PMID:29176886

  19. Differences in phonetic discrimination stem from differences in psychoacoustic abilities in learning the sounds of a second language: Evidence from ERP research.

    PubMed

    Lin, Yi; Fan, Ruolin; Mo, Lei

    2017-01-01

    The scientific community has been divided as to the origin of individual differences in perceiving the sounds of a second language (L2). There are two alternative explanations: a general psychoacoustic origin vs. a speech-specific one. A previous study showed that such individual variability is linked to the perceivers' speech-specific capabilities, rather than the perceivers' psychoacoustic abilities. However, we assume that the selection of participants and parameters of sound stimuli might not appropriate. Therefore, we adjusted the sound stimuli and recorded event-related potentials (ERPs) from two groups of early, proficient Cantonese (L1)-Mandarin (L2) bilinguals who differed in their mastery of the Mandarin (L2) phonetic contrast /in-ing/, to explore whether the individual differences in perceiving L2 stem from participants' ability to discriminate various pure tones (frequency, duration and pattern). To precisely measure the participants' acoustic discrimination, mismatch negativity (MMN) elicited by the oddball paradigm was recorded in the experiment. The results showed that significant differences between good perceivers (GPs) and poor perceivers (PPs) were found in the three general acoustic conditions (frequency, duration and pattern), and the MMN amplitude for GP was significantly larger than for PP. Therefore, our results support a general psychoacoustic origin of individual variability in L2 phonetic mastery.

  20. Metabolic syndrome and hypertension: regular exercise as part of lifestyle management.

    PubMed

    Lackland, Daniel T; Voeks, Jenifer H

    2014-11-01

    The incorporation of physical activity and exercise represents a clinically important aspect in the management of metabolic syndrome, hypertension, and diabetes. While the benefit of exercise and active lifestyles is well documented for prevention and risk reduction of cardiovascular and stroke outcomes, the detailed regiment and recommendations are less clear. The components of a prescribed physical activity include consideration of activity type, frequency of an activity, activity duration, and intensity of a specific physical movement. The exercise parameters prescribed as part of the management of metabolic syndrome, diabetes, and elevated blood pressure are most often proposed as separate documents while the general recommendations are similar. The evidence is strong such that physical activity and exercise recommendations in disease management guidelines are considered high quality. The general recommendations for both blood pressure and glycemic management include a regiment of physical activity with moderate- to high-intensity exercise of 30-min bouts on multiple days with a desired goal of a total of 150 min of exercise per week. While additional research is needed to identify the specific exercise/activity mode, frequencies for exercise training, intensity levels, and duration of exercise that achieve maximal blood pressure and glycemic lowering, this general recommendation showed a consistent and significant benefit in risk reduction. Similarly, the current available evidence also indicates that aerobic exercise, dynamic resistance exercise, and isometric exercises can lower blood pressure and improve glycemic control.

  1. Tactile stimulation during neonatal transition and its effect on vital parameters in neonates during neonatal transition.

    PubMed

    Baik-Schneditz, Nariae; Urlesberger, Berndt; Schwaberger, Bernhard; Mileder, Lukas; Schmölzer, Georg; Avian, Alexander; Pichler, Gerhard

    2018-06-01

    This study analysed tactile stimulation during neonatal transition and resuscitation in preterm and term neonates born by Caesarean delivery. It examined the frequency, location and body region, duration and possible effects of stimulation on heart rate and arterial oxygen saturation (SpO 2 ). Two independent investigators analysed video recordings of tactile stimulation on term and preterm neonates during neonatal transition from January 2012 to December 2014. They were recorded during a prospective observational study and randomised controlled trial at a tertiary centre, the Medical University of Graz, Austria. SpO 2 and heart rate were continuously recorded. Data on the frequency, body region and duration of stimulation were collected. To investigate the possible effects of stimulation, SpO 2 and heart rate were compared before and after stimulation. Term infants received tactile stimulation more than once, and it tended to start later, last longer and be applied in more locations than in preterm infants. Only preterm infants showed a significant increase in SpO 2 after stimulation and heart rates did not show any significant changes in either group. Tactile stimulation was applied in different ways to preterm and term infants during neonatal transition and SpO 2 showed a significant increase in preterm infants. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. Characteristics of whistles from rough-toothed dolphins (Steno bredanensis) in Rio de Janeiro coast, southeastern Brazil.

    PubMed

    Seabra de Lima, Isabela Maria; de Andrade, Luciana Guimarães; Ramos de Carvalho, Rafael; Lailson-Brito, José; de Freitas Azevedo, Alexandre

    2012-05-01

    There is no information about the whistles of rough-toothed dolphins in the South Atlantic Ocean. This study characterizes the whistle structure of free-ranging rough-toothed dolphins recorded on the Rio de Janeiro coast, southeastern Brazil, and compares it to that of the same species in other regions. A total of 340 whistles were analyzed. Constant (N = 115; 33.8%) and ascending (N = 99; 29.1%) whistles were the most common contours. The whistles recorded had their fundamental frequencies between 2.24 and 13.94 kHz. Whistles without inflection points were frequently emitted (N = 255; 75%). Some signals presented breaks or steps in their contour (N = 97; 28.5%). Whistle duration was short (347 ± 236 ms and 89.7% of the whistles lasted <600 ms). Seventy-eight whistle contour types were found in the total of whistles analyzed, and 27 (7.9%) of these occurred only once. Most of the whistle types were unique to a particular recording session (N = 43). The signals emitted by the rough-toothed dolphins in southeastern Brazil were characterized by low frequency modulation, short duration, low number of inflection points, and breaks. Differences in the mean values of the whistle parameters were found between this and other studies that recorded Steno bredanensis, but as in other localities, whistles above 14 kHz are rare.

  3. Sociodemographic characteristics associated with frequency and duration of eating family meals: a cross-sectional analysis.

    PubMed

    Skeer, Margie R; Yantsides, Konstantina E; Eliasziw, Misha; Tracy, Migdalia R; Carlton-Smith, Allison R; Spirito, Anthony

    2016-01-01

    Children who frequently eat family meals are less likely to develop risk- and behavior-related outcomes, such as substance misuse, sexual risk, and obesity. Few studies have examined sociodemographic characteristics associated with both meal frequency (i.e., number of meals) and duration (i.e., number of minutes spent at mealtimes). We examine the association between sociodemographics and family meal frequency and duration among a sample of 85 parents in a large New England city that was recruited through the public-school system. Additionally, we examined differences in family meals by race/ethnicity and parental nativity. Unadjusted ANOVA and adjusted ANCOVA models were used to assess the associations between sociodemographic characteristics and frequency and duration of meals. Sociodemographic characteristics were not significantly associated with the frequency of family meals; however, in the adjusted models, differences were associated with duration of meals. Parents who were born outside the U.S. spent an average of 135.0 min eating meals per day with their children compared to 76.2 for parents who were born in the U.S. ( p  < 0.01). Additionally, parents who reported being single, divorced, or separated on average, spent significantly more time per day eating family meals (126.7 min) compared to parents who reported being married or partnered (84.4; p  = 0.02). Differences existed in meal duration by parental nativity and race/ethnicity, ranging from 63.7 min among multi-racial/other parents born in the U.S. to 182.8 min among black parents born outside the U.S. This study builds a foundation for focused research into the mechanisms of family meals. Future longitudinal epidemiologic research on family meals may help to delineate targets for prevention of maladaptive behaviors, which could affect family-based practices, interventions, and policies.

  4. Electrocardiographic parameters predict super-response in cardiac resynchronization therapy.

    PubMed

    Cvijić, Marta; Žižek, David; Antolič, Bor; Zupan, Igor

    2015-01-01

    Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. However, determinants of response to CRT remain elusive. The aim of the study was to assess the value of ECG parameters to predict super-response in CRT patients. A 12-lead surface ECG was recorded at baseline and immediately after CRT-device implantation. Baseline ECG parameters (QRS duration, bundle branch morphology, axis, PR interval, QTc, intrinsicoid deflection) and post-implant paced QRS duration were analyzed; relative change in QRS duration was calculated. Decrease of left ventricular end-systolic volume ≥30% after 12 months was classified as super-response. In group of 101 patients, 32 (31.7%) were super-responders. There were no significant differences in baseline ECG parameters between super-responders and other patients. Post-implant QRS duration was shorter in super-responders (148 ± 22 ms vs. 162 ± 28 ms; P=0.010). Only in super-responders was significant QRS reduction observed after implantation. Relative QRS shortening was higher in super-responders (12.1% (6.8 to 22.2) vs. 1.7% (-11.9 to 11.8); P=0.005). In a multivariable analysis post-implant QRS duration and relative QRS shortening remained independent predictor of super-response. Absolute post-implant QRS duration and relative QRS shortening are the only ECG parameters associated with super-response in CRT. Further prospective studies on larger population are warranted to determine our findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Scaling A Moment-Rate Function For Small To Large Magnitude Events

    NASA Astrophysics Data System (ADS)

    Archuleta, Ralph; Ji, Chen

    2017-04-01

    Since the 1980's seismologists have recognized that peak ground acceleration (PGA) and peak ground velocity (PGV) scale differently with magnitude for large and moderate earthquakes. In a recent paper (Archuleta and Ji, GRL 2016) we introduced an apparent moment-rate function (aMRF) that accurately predicts the scaling with magnitude of PGA, PGV, PWA (Wood-Anderson Displacement) and the ratio PGA/2πPGV (dominant frequency) for earthquakes 3.3 ≤ M ≤ 5.3. This apparent moment-rate function is controlled by two temporal parameters, tp and td, which are related to the time for the moment-rate function to reach its peak amplitude and the total duration of the earthquake, respectively. These two temporal parameters lead to a Fourier amplitude spectrum (FAS) of displacement that has two corners in between which the spectral amplitudes decay as 1/f, f denotes frequency. At higher or lower frequencies, the FAS of the aMRF looks like a single-corner Aki-Brune omega squared spectrum. However, in the presence of attenuation the higher corner is almost certainly masked. Attempting to correct the spectrum to an Aki-Brune omega-squared spectrum will produce an "apparent" corner frequency that falls between the double corner frequency of the aMRF. We reason that the two corners of the aMRF are the reason that seismologists deduce a stress drop (e.g., Allmann and Shearer, JGR 2009) that is generally much smaller than the stress parameter used to produce ground motions from stochastic simulations (e.g., Boore, 2003 Pageoph.). The presence of two corners for the smaller magnitude earthquakes leads to several questions. Can deconvolution be successfully used to determine scaling from small to large earthquakes? Equivalently will large earthquakes have a double corner? If large earthquakes are the sum of many smaller magnitude earthquakes, what should the displacement FAS look like for a large magnitude earthquake? Can a combination of such a double-corner spectrum and random vibration theory explain the PGA, PGV scaling relationships for larger magnitude?

  6. Seismic Moment, Seismic Energy, and Source Duration of Slow Earthquakes: Application of Brownian slow earthquake model to three major subduction zones

    NASA Astrophysics Data System (ADS)

    Ide, Satoshi; Maury, Julie

    2018-04-01

    Tectonic tremors, low-frequency earthquakes, very low-frequency earthquakes, and slow slip events are all regarded as components of broadband slow earthquakes, which can be modeled as a stochastic process using Brownian motion. Here we show that the Brownian slow earthquake model provides theoretical relationships among the seismic moment, seismic energy, and source duration of slow earthquakes and that this model explains various estimates of these quantities in three major subduction zones: Japan, Cascadia, and Mexico. While the estimates for these three regions are similar at the seismological frequencies, the seismic moment rates are significantly different in the geodetic observation. This difference is ascribed to the difference in the characteristic times of the Brownian slow earthquake model, which is controlled by the width of the source area. We also show that the model can include non-Gaussian fluctuations, which better explains recent findings of a near-constant source duration for low-frequency earthquake families.

  7. Behavioral analysis of signals that guide learned changes in the amplitude and dynamics of the vestibulo-ocular reflex.

    PubMed

    Raymond, J L; Lisberger, S G

    1996-12-01

    We characterized the dependence of motor learning in the monkey vestibulo-ocular reflex (VOR) on the duration, frequency, and relative timing of the visual and vestibular stimuli used to induce learning. The amplitude of the VOR was decreased or increased through training with paired head and visual stimulus motion in the same or opposite directions, respectively. For training stimuli that consisted of simultaneous pulses of head and target velocity 80-1000 msec in duration, brief stimuli caused small changes in the amplitude of the VOR, whereas long stimuli caused larger changes in amplitude as well as changes in the dynamics of the reflex. When the relative timing of the visual and vestibular stimuli was varied, brief image motion paired with the beginning of a longer vestibular stimulus caused changes in the amplitude of the reflex alone, but the same image motion paired with a later time in the vestibular stimulus caused changes in the dynamics as well as the amplitude of the VOR. For training stimuli that consisted of sinusoidal head and visual stimulus motion, low-frequency training stimuli induced frequency-selective changes in the VOR, as reported previously, whereas high-frequency training stimuli induced changes in the amplitude of the VOR that were more similar across test frequency. The results suggest that there are at least two distinguishable components of motor learning in the VOR. One component is induced by short-duration or high-frequency stimuli and involves changes in only the amplitude of the reflex. A second component is induced by long-duration or low-frequency stimuli and involves changes in the amplitude and dynamics of the VOR.

  8. Behavioral analysis of signals that guide learned changes in the amplitude and dynamics of the vestibulo-ocular reflex

    NASA Technical Reports Server (NTRS)

    Raymond, J. L.; Lisberger, S. G.

    1996-01-01

    We characterized the dependence of motor learning in the monkey vestibulo-ocular reflex (VOR) on the duration, frequency, and relative timing of the visual and vestibular stimuli used to induce learning. The amplitude of the VOR was decreased or increased through training with paired head and visual stimulus motion in the same or opposite directions, respectively. For training stimuli that consisted of simultaneous pulses of head and target velocity 80-1000 msec in duration, brief stimuli caused small changes in the amplitude of the VOR, whereas long stimuli caused larger changes in amplitude as well as changes in the dynamics of the reflex. When the relative timing of the visual and vestibular stimuli was varied, brief image motion paired with the beginning of a longer vestibular stimulus caused changes in the amplitude of the reflex alone, but the same image motion paired with a later time in the vestibular stimulus caused changes in the dynamics as well as the amplitude of the VOR. For training stimuli that consisted of sinusoidal head and visual stimulus motion, low-frequency training stimuli induced frequency-selective changes in the VOR, as reported previously, whereas high-frequency training stimuli induced changes in the amplitude of the VOR that were more similar across test frequency. The results suggest that there are at least two distinguishable components of motor learning in the VOR. One component is induced by short-duration or high-frequency stimuli and involves changes in only the amplitude of the reflex. A second component is induced by long-duration or low-frequency stimuli and involves changes in the amplitude and dynamics of the VOR.

  9. Comparison of three-parameter probability distributions for representing annual extreme and partial duration precipitation series

    NASA Astrophysics Data System (ADS)

    Wilks, Daniel S.

    1993-10-01

    Performance of 8 three-parameter probability distributions for representing annual extreme and partial duration precipitation data at stations in the northeastern and southeastern United States is investigated. Particular attention is paid to fidelity on the right tail, through use of a bootstrap procedure simulating extrapolation on the right tail beyond the data. It is found that the beta-κ distribution best describes the extreme right tail of annual extreme series, and the beta-P distribution is best for the partial duration data. The conventionally employed two-parameter Gumbel distribution is found to substantially underestimate probabilities associated with the larger precipitation amounts for both annual extreme and partial duration data. Fitting the distributions using left-censored data did not result in improved fits to the right tail.

  10. Variations of bubble cavitation and temperature elevation during lesion formation by high-intensity focused ultrasound.

    PubMed

    Zhou, Yufeng; Gao, Xiaobin Wilson

    2013-08-01

    High-intensity focused ultrasound (HIFU) is emerging as an effective therapeutic modality in both thermal ablations for solid tumor/cancer and soft-tissue fragmentation. Mechanical and thermal effects, which play an important role in the HIFU treatment simultaneously, are dependent on the operating parameters and may vary with the progress of therapy. Mechanical erosion in the shape of a "squid," a "dumbbell" lesion with both mechanical and thermal lesions, or a "tadpole" lesion with mechanical erosion at the center and thermal necrosis on the boundary in the transparent gel phantom could be produced correspondingly with the pulse duration of 5-30 ms, which is much longer than histotripsy burst but shorter than the time for tissue boiling, and pulse repetition frequency (PRF) of 0.2-5 Hz. Meanwhile, variations of bubble cavitation (both inertial and stable cavitation) and temperature elevation in the focal region (i.e., z = -2.5, 0, and 2.5 mm) were measured by passive cavitation detection (PCD) and thermocouples during the therapeutic procedure, respectively. Stable cavitation increased with the pulse duration, PRF, and the number of pulses delivered. However, inertial cavitation was found to increase initially and then decrease with long pulse duration and high PRF. Temperature in the pre-focal region is always higher than those at the focal and post-focal position in all tests. Great variations of PCD signals and temperature elevation are due to the generation and persistence of large bubble, which is resistant to collapse and occurs with the increase of pulse duration and PRF. Similar lesion pattern and variations were also observed in ex vivo porcine kidneys. Hyperechoes in the B-mode ultrasound image were comparable to the shape and size of lesions in the dissected tissue. Thermal lesion volume increased with the increase of pulse duration and PRF, but mechanical erosion reached its maximum volume with the pulse duration of 20 ms and PRF of 1 Hz. Altogether, bubble cavitation and thermal field vary with the progress of HIFU treatment with different sonication parameters, which provide insights into the interaction of ultrasound burst with the induced bubbles for both soft tissue fractionation and enhancement in thermal accumulation. Appropriate synergy and monitoring of mechanical and thermal effects would broaden the HIFU application and enhance its efficiency as well as safety.

  11. "Change deafness" arising from inter-feature masking within a single auditory object.

    PubMed

    Barascud, Nicolas; Griffiths, Timothy D; McAlpine, David; Chait, Maria

    2014-03-01

    Our ability to detect prominent changes in complex acoustic scenes depends not only on the ear's sensitivity but also on the capacity of the brain to process competing incoming information. Here, employing a combination of psychophysics and magnetoencephalography (MEG), we investigate listeners' sensitivity in situations when two features belonging to the same auditory object change in close succession. The auditory object under investigation is a sequence of tone pips characterized by a regularly repeating frequency pattern. Signals consisted of an initial, regularly alternating sequence of three short (60 msec) pure tone pips (in the form ABCABC…) followed by a long pure tone with a frequency that is either expected based on the on-going regular pattern ("LONG expected"-i.e., "LONG-expected") or constitutes a pattern violation ("LONG-unexpected"). The change in LONG-expected is manifest as a change in duration (when the long pure tone exceeds the established duration of a tone pip), whereas the change in LONG-unexpected is manifest as a change in both the frequency pattern and a change in the duration. Our results reveal a form of "change deafness," in that although changes in both the frequency pattern and the expected duration appear to be processed effectively by the auditory system-cortical signatures of both changes are evident in the MEG data-listeners often fail to detect changes in the frequency pattern when that change is closely followed by a change in duration. By systematically manipulating the properties of the changing features and measuring behavioral and MEG responses, we demonstrate that feature changes within the same auditory object, which occur close together in time, appear to compete for perceptual resources.

  12. Psychosocial factors associated with work disability in men and women with diabetes: a pooled analysis of three occupational cohort studies.

    PubMed

    Ervasti, J; Kivimäki, M; Dray-Spira, R; Head, J; Goldberg, M; Pentti, J; Jokela, M; Vahtera, J; Zins, M; Virtanen, M

    2016-02-01

    To examine the extent to which adverse psychosocial factors, such as living alone, psychological distress, job strain and low support from supervisor, increase the risk of work disability (sickness absence and disability pension) among employees with diabetes. In this pooled analysis of individual-participant data from three occupational cohort studies (the Finnish Public Sector Study, the British Whitehall II study, and the French GAZEL study), 1088 women and 949 men with diabetes were followed up to determine the duration (number of days) and frequency (number of spells) of work disability. The mean follow-up periods were 3.2 years in the GAZEL study, 4.6 years in the Whitehall II study and 4.7 years in the Finnish Public Sector Study. Psychosocial factors and potential confounding factors were assessed at baseline using standard questionnaires. Study-specific estimates were pooled using fixed-effects meta-analysis. In analysis adjusted for sociodemographic factors, health behaviours and comorbidities, participants with psychological distress had longer (rate ratio 1.66; 95% CI 1.31-2.09) and more frequent absences (rate ratio 1.33; 95% CI 1.19-1.49) compared with those with no psychological distress. Job strain was associated with slightly increased absence frequency (rate ratio 1.19 95% CI 1.05-1.35), but not with absence duration. Living alone and low supervisor support were not associated with absence duration or frequency. We observed no sex differences in these associations. Psychological distress was associated with increased duration and frequency of work disability among employees with diabetes. Job strain was associated with increased absence frequency but not with absence duration. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  13. Classifying low flow hydrological regimes at a regional scale

    NASA Astrophysics Data System (ADS)

    Kirkby, M. J.; Gallart, F.; Kjeldsen, T. R.; Irvine, B. J.; Froebrich, J.; Lo Porto, A.; de Girolamo, A.; Mirage Team

    2011-12-01

    The paper uses a simple water balance model that partitions the precipitation between actual evapotranspiration, quick flow and delayed flow, and has sufficient complexity to capture the essence of climate and vegetation controls on this partitioning. Using this model, monthly flow duration curves have been constructed from climate data across Europe to address the relative frequency of ecologically critical low flow stages in semi-arid rivers, when flow commonly persists only in disconnected pools in the river bed. The hydrological model is based on a dynamic partitioning of precipitation to estimate water available for evapotranspiration and plant growth and for residual runoff. The duration curve for monthly flows has then been analysed to give an estimate of bankfull flow based on recurrence interval. Arguing from observed ratios of cross-sectional areas at flood and low flows, hydraulic geometry suggests that disconnected flow under "pool" conditions is approximately 0.1% of bankfull flow. Flow duration curves define a measure of bankfull discharge on the basis of frequency. The corresponding frequency for pools is then read from the duration curve, using this (0.1%) ratio to estimate pool discharge from bank full discharge. The flow duration curve then provides an estimate of the frequency of poorly connected pool conditions, corresponding to this discharge, that constrain survival of river-dwelling arthropods and fish. The methodology has here been applied across Europe at 15 km resolution, and the potential is demonstrated for applying the methodology under alternative climatic scenarios.

  14. Statistical Study in the mid-altitude cusp region: wave and particle data comparison using a normalized cusp crossing duration

    NASA Astrophysics Data System (ADS)

    Grison, B.; Escoubet, C. P.; Pitout, F.; Cornilleau-Wehrlin, N.; Dandouras, I.; Lucek, E.

    2009-04-01

    In the mid altitude cusp region the DC magnetic field presents a diamagnetic cavity due to intense ion earthward flux coming from the magnetosheath. A strong ultra low frequency (ULF) magnetic activity is also commonly observed in this region. Most of the mid altitude cusp statistical studies have focused on the location of the cusp and its dependence and response to solar wind, interplanetary magnetic field, dipole tilt angle parameters. In our study we use the database build by Pitout et al. (2006) in order to study the link of wave power in the ULF range (0.35-10Hz) measured by STAFF SC instrument with the ion plasma properties as measured by CIS (and CODIF) instrument as well as the diamagnetic cavity in the mid-altitude cusp region with FGM data. To compare the different crossings we don`t use the cusp position and dynamics but we use a normalized cusp crossing duration that permits to easily average the properties over a large number of crossings. As usual in the cusp, it is particularly relevant to sort the crossings by the corresponding interplanetary magnetic field (IMF) orientation in order to analyse the results. In particular we try to find out what is the most relevant parameter to link the strong wave activity with. The global statistic confirms previous single case observations that have noticed a simultaneity between ion injections and wave activity enhancements. We will also present results concerning other ion parameters and the diamagnetic cavity observed in the mid altitude cusp region.

  15. The role of exercise and gender for physical self-perceptions and importance ratings in Swedish university students.

    PubMed

    Lindwall, Magnus; Hassmén, Peter

    2004-12-01

    The purpose of this study was to investigate how scores on the Physical Self-Perception Profile (PSPP), including scores on the Perceived Importance Profile (PIP), were related to self-reported exercise frequency, duration, and gender in sample of Swedish university students. A total of 164 participants completed the PSPP, PIP, and a questionnaire focusing on frequency and duration of exercise. Exercise frequency, duration, and gender predicted best the PSPP sub-domains of Sport Competence and Physical Conditioning. Exercising more frequently, and for a longer time on each occasion was associated with higher PSPP and PIP scores. Women generally displayed lower PSPP scores than men. These results suggest that exercise professionals need to master a range of appropriate exercise strategies, since doubts concerning self-presentation may work against establishing a regular exercise routine.

  16. Development of regional skews for selected flood durations for the Central Valley Region, California, based on data through water year 2008

    USGS Publications Warehouse

    Lamontagne, Jonathan R.; Stedinger, Jery R.; Berenbrock, Charles; Veilleux, Andrea G.; Ferris, Justin C.; Knifong, Donna L.

    2012-01-01

    Flood-frequency information is important in the Central Valley region of California because of the high risk of catastrophic flooding. Most traditional flood-frequency studies focus on peak flows, but for the assessment of the adequacy of reservoirs, levees, other flood control structures, sustained flood flow (flood duration) frequency data are needed. This study focuses on rainfall or rain-on-snow floods, rather than the annual maximum, because rain events produce the largest floods in the region. A key to estimating flood-duration frequency is determining the regional skew for such data. Of the 50 sites used in this study to determine regional skew, 28 sites were considered to have little to no significant regulated flows, and for the 22 sites considered significantly regulated, unregulated daily flow data were synthesized by using reservoir storage changes and diversion records. The unregulated, annual maximum rainfall flood flows for selected durations (1-day, 3-day, 7-day, 15-day, and 30-day) for all 50 sites were furnished by the U.S. Army Corps of Engineers. Station skew was determined by using the expected moments algorithm program for fitting the Pearson Type 3 flood-frequency distribution to the logarithms of annual flood-duration data. Bayesian generalized least squares regression procedures used in earlier studies were modified to address problems caused by large cross correlations among concurrent rainfall floods in California and to address the extensive censoring of low outliers at some sites, by using the new expected moments algorithm for fitting the LP3 distribution to rainfall flood-duration data. To properly account for these problems and to develop suitable regional-skew regression models and regression diagnostics, a combination of ordinary least squares, weighted least squares, and Bayesian generalized least squares regressions were adopted. This new methodology determined that a nonlinear model relating regional skew to mean basin elevation was the best model for each flood duration. The regional-skew values ranged from -0.74 for a flood duration of 1-day and a mean basin elevation less than 2,500 feet to values near 0 for a flood duration of 7-days and a mean basin elevation greater than 4,500 feet. This relation between skew and elevation reflects the interaction of snow and rain, which increases with increased elevation. The regional skews are more accurate, and the mean squared errors are less than in the Interagency Advisory Committee on Water Data's National skew map of Bulletin 17B.

  17. Learning reduced kinetic Monte Carlo models of complex chemistry from molecular dynamics.

    PubMed

    Yang, Qian; Sing-Long, Carlos A; Reed, Evan J

    2017-08-01

    We propose a novel statistical learning framework for automatically and efficiently building reduced kinetic Monte Carlo (KMC) models of large-scale elementary reaction networks from data generated by a single or few molecular dynamics simulations (MD). Existing approaches for identifying species and reactions from molecular dynamics typically use bond length and duration criteria, where bond duration is a fixed parameter motivated by an understanding of bond vibrational frequencies. In contrast, we show that for highly reactive systems, bond duration should be a model parameter that is chosen to maximize the predictive power of the resulting statistical model. We demonstrate our method on a high temperature, high pressure system of reacting liquid methane, and show that the learned KMC model is able to extrapolate more than an order of magnitude in time for key molecules. Additionally, our KMC model of elementary reactions enables us to isolate the most important set of reactions governing the behavior of key molecules found in the MD simulation. We develop a new data-driven algorithm to reduce the chemical reaction network which can be solved either as an integer program or efficiently using L1 regularization, and compare our results with simple count-based reduction. For our liquid methane system, we discover that rare reactions do not play a significant role in the system, and find that less than 7% of the approximately 2000 reactions observed from molecular dynamics are necessary to reproduce the molecular concentration over time of methane. The framework described in this work paves the way towards a genomic approach to studying complex chemical systems, where expensive MD simulation data can be reused to contribute to an increasingly large and accurate genome of elementary reactions and rates.

  18. Learning reduced kinetic Monte Carlo models of complex chemistry from molecular dynamics

    PubMed Central

    Sing-Long, Carlos A.

    2017-01-01

    We propose a novel statistical learning framework for automatically and efficiently building reduced kinetic Monte Carlo (KMC) models of large-scale elementary reaction networks from data generated by a single or few molecular dynamics simulations (MD). Existing approaches for identifying species and reactions from molecular dynamics typically use bond length and duration criteria, where bond duration is a fixed parameter motivated by an understanding of bond vibrational frequencies. In contrast, we show that for highly reactive systems, bond duration should be a model parameter that is chosen to maximize the predictive power of the resulting statistical model. We demonstrate our method on a high temperature, high pressure system of reacting liquid methane, and show that the learned KMC model is able to extrapolate more than an order of magnitude in time for key molecules. Additionally, our KMC model of elementary reactions enables us to isolate the most important set of reactions governing the behavior of key molecules found in the MD simulation. We develop a new data-driven algorithm to reduce the chemical reaction network which can be solved either as an integer program or efficiently using L1 regularization, and compare our results with simple count-based reduction. For our liquid methane system, we discover that rare reactions do not play a significant role in the system, and find that less than 7% of the approximately 2000 reactions observed from molecular dynamics are necessary to reproduce the molecular concentration over time of methane. The framework described in this work paves the way towards a genomic approach to studying complex chemical systems, where expensive MD simulation data can be reused to contribute to an increasingly large and accurate genome of elementary reactions and rates. PMID:28989618

  19. Learning reduced kinetic Monte Carlo models of complex chemistry from molecular dynamics

    DOE PAGES

    Yang, Qian; Sing-Long, Carlos A.; Reed, Evan J.

    2017-06-19

    Here, we propose a novel statistical learning framework for automatically and efficiently building reduced kinetic Monte Carlo (KMC) models of large-scale elementary reaction networks from data generated by a single or few molecular dynamics simulations (MD). Existing approaches for identifying species and reactions from molecular dynamics typically use bond length and duration criteria, where bond duration is a fixed parameter motivated by an understanding of bond vibrational frequencies. Conversely, we show that for highly reactive systems, bond duration should be a model parameter that is chosen to maximize the predictive power of the resulting statistical model. We demonstrate our methodmore » on a high temperature, high pressure system of reacting liquid methane, and show that the learned KMC model is able to extrapolate more than an order of magnitude in time for key molecules. Additionally, our KMC model of elementary reactions enables us to isolate the most important set of reactions governing the behavior of key molecules found in the MD simulation. We develop a new data-driven algorithm to reduce the chemical reaction network which can be solved either as an integer program or efficiently using L1 regularization, and compare our results with simple count-based reduction. For our liquid methane system, we discover that rare reactions do not play a significant role in the system, and find that less than 7% of the approximately 2000 reactions observed from molecular dynamics are necessary to reproduce the molecular concentration over time of methane. Furthermore, we describe a framework in this work that paves the way towards a genomic approach to studying complex chemical systems, where expensive MD simulation data can be reused to contribute to an increasingly large and accurate genome of elementary reactions and rates.« less

  20. Is there a first night effect on sleep bruxism? A sleep laboratory study.

    PubMed

    Hasegawa, Yoko; Lavigne, Gilles; Rompré, Pierre; Kato, Takafumi; Urade, Masahiro; Huynh, Nelly

    2013-11-15

    Sleep bruxism (SB) is reported to vary in frequency over time. The aim of this study was to assess the first night effect on SB. A retrospective polysomnographic (PSG) analysis was performed of data from a sample of SB patients (12 females, 4 males; age range: 17-39 years) recorded in a sleep laboratory over 2 consecutive nights. Sleep parameters and jaw muscle activity variables (i.e., rhythmic masticatory muscle activity [RMMA]) for SB were quantified and compared between the 2 nights. Subjects were classified into groups according to severity of RMMA frequency, such as low frequency (2-4 episodes/h and/or < 25 bursts/h) and moderate-high frequency (≥ 4 episodes/h and ≥ 25 bursts/h). Overall, no first night effects were found for most sleep variables. However, total sleep time, sleep efficiency, and stage transitions showed significant time and group interactions (repeated measures ANOVAs, p ≤ 0.05). The RMMA episode index did not differ between the 2 nights, whereas the second night showed significantly higher burst index, bruxism time index, and mean burst duration (repeated measure ANOVAs, p ≤ 0.05). Five patients of 8 in the low frequency group were classified into the moderate-high frequency group on the second night, whereas only one patient in the moderate-high frequency group moved to the low frequency group. The results showed no overall first night effect on severity of RMMA frequency in young and healthy patients with SB. In clinical practice, one-night sleep recording may be sufficient for moderate-high frequency SB patients. However, low RMMA frequency in the first night could be confirmed by a second night based on the patient's medical and dental history.

  1. Effects of psychological stress test on the cardiac response of public safety workers: alternative parameters to autonomic balance

    NASA Astrophysics Data System (ADS)

    Huerta-Franco, M. R.; Vargas-Luna, F. M.; Delgadillo-Holtfort, I.

    2015-01-01

    It is well known that public safety workers (PSW) face many stressful situations that yield them as high-risk population for suffering chronic stress diseases. In this multidisciplinary research the cardiac response to induced psychological stress by a short duration Stroop test was evaluated in 20 female and 19 male PSW, in order to compare traditionally used cardiac response parameters with alternative ones. Electrocardiograms have been recorded using the Eindhoven electrodes configuration for 1 min before, 3 min during and 1 min after the test. Signals analysis has been performed for the heart rate and the power spectra of its variability and of the variability of the amplitude of the R-wave, i.e. the highest peak of the electrocardiographic signal periodic sequence. The results demonstrated that the traditional autonomic balance index shows no significant differences between stages. In contrast, the median of the area of the power spectrum of the R-wave amplitude variability in the frequency region dominated by the autonomous nervous system (0.04-to-0.4 Hz) is the more sensitive parameter. Moreover, this parameter allows to identify gender differences consistent with those encountered in other studies.

  2. Repetitive Transcranial Magnetic Stimulator with Controllable Pulse Parameters

    PubMed Central

    Peterchev, Angel V; Murphy, David L; Lisanby, Sarah H

    2013-01-01

    The characteristics of transcranial magnetic stimulation (TMS) pulses influence the physiological effect of TMS. However, available TMS devices allow very limited adjustment of the pulse parameters. We describe a novel TMS device that uses a circuit topology incorporating two energy storage capacitors and two insulated-gate bipolar transistor (IGBT) modules to generate near-rectangular electric field pulses with adjustable number, polarity, duration, and amplitude of the pulse phases. This controllable pulse parameter TMS (cTMS) device can induce electric field pulses with phase widths of 10–310 μs and positive/negative phase amplitude ratio of 1–56. Compared to conventional monophasic and biphasic TMS, cTMS reduces energy dissipation by up to 82% and 57%, and decreases coil heating by up to 33% and 41%, respectively. We demonstrate repetitive TMS trains of 3,000 pulses at frequencies up to 50 Hz with electric field pulse amplitude and width variability less than the measurement resolution (1.7% and 1%, respectively). Offering flexible pulse parameter adjustment and reduced power consumption and coil heating, cTMS enhances existing TMS paradigms, enables novel research applications, and could lead to clinical applications with potentially enhanced potency. PMID:21540487

  3. Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.

    PubMed

    Onisor, I; Pecie, R; Chaskelis, I; Krejci, I

    2013-06-01

    To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.

  4. Evaluating physical function and activity in the elderly patient using wearable motion sensors.

    PubMed

    Grimm, Bernd; Bolink, Stijn

    2016-05-01

    Wearable sensors, in particular inertial measurement units (IMUs) allow the objective, valid, discriminative and responsive assessment of physical function during functional tests such as gait, stair climbing or sit-to-stand.Applied to various body segments, precise capture of time-to-task achievement, spatiotemporal gait and kinematic parameters of demanding tests or specific to an affected limb are the most used measures.In activity monitoring (AM), accelerometry has mainly been used to derive energy expenditure or general health related parameters such as total step counts.In orthopaedics and the elderly, counting specific events such as stairs or high intensity activities were clinimetrically most powerful; as were qualitative parameters at the 'micro-level' of activity such as step frequency or sit-stand duration.Low cost and ease of use allow routine clinical application but with many options for sensors, algorithms, test and parameter definitions, choice and comparability remain difficult, calling for consensus or standardisation. Cite this article: Grimm B, Bolink S. Evaluating physical function and activity in the elderly patient using wearable motion sensors. EFORT Open Rev 2016;1:112-120. DOI: 10.1302/2058-5241.1.160022.

  5. Evaluating physical function and activity in the elderly patient using wearable motion sensors

    PubMed Central

    Grimm, Bernd; Bolink, Stijn

    2016-01-01

    Wearable sensors, in particular inertial measurement units (IMUs) allow the objective, valid, discriminative and responsive assessment of physical function during functional tests such as gait, stair climbing or sit-to-stand. Applied to various body segments, precise capture of time-to-task achievement, spatiotemporal gait and kinematic parameters of demanding tests or specific to an affected limb are the most used measures. In activity monitoring (AM), accelerometry has mainly been used to derive energy expenditure or general health related parameters such as total step counts. In orthopaedics and the elderly, counting specific events such as stairs or high intensity activities were clinimetrically most powerful; as were qualitative parameters at the ‘micro-level’ of activity such as step frequency or sit-stand duration. Low cost and ease of use allow routine clinical application but with many options for sensors, algorithms, test and parameter definitions, choice and comparability remain difficult, calling for consensus or standardisation. Cite this article: Grimm B, Bolink S. Evaluating physical function and activity in the elderly patient using wearable motion sensors. EFORT Open Rev 2016;1:112–120. DOI: 10.1302/2058-5241.1.160022. PMID:28461937

  6. Analysis of flash flood parameters and human impacts in the US from 2006 to 2012

    NASA Astrophysics Data System (ADS)

    Špitalar, Maruša; Gourley, Jonathan J.; Lutoff, Celine; Kirstetter, Pierre-Emmanuel; Brilly, Mitja; Carr, Nicholas

    2014-11-01

    Several different factors external to the natural hazard of flash flooding can contribute to the type and magnitude of their resulting damages. Human exposure, vulnerability, fatality and injury rates can be minimized by identifying and then mitigating the causative factors for human impacts. A database of flash flooding was used for statistical analysis of human impacts across the U.S. 21,549 flash flood events were analyzed during a 6-year period from October 2006 to 2012. Based on the information available in the database, physical parameters were introduced and then correlated to the reported human impacts. Probability density functions of the frequency of flash flood events and the PDF of occurrences weighted by the number of injuries and fatalities were used to describe the influence of each parameter. The factors that emerged as the most influential on human impacts are short flood durations, small catchment sizes in rural areas, vehicles, and nocturnal events with low visibility. Analyzing and correlating a diverse range of parameters to human impacts give us important insights into what contributes to fatalities and injuries and further raises questions on how to manage them.

  7. Phase noise in pulsed Doppler lidar and limitations on achievable single-shot velocity accuracy

    NASA Technical Reports Server (NTRS)

    Mcnicholl, P.; Alejandro, S.

    1992-01-01

    The smaller sampling volumes afforded by Doppler lidars compared to radars allows for spatial resolutions at and below some sheer and turbulence wind structure scale sizes. This has brought new emphasis on achieving the optimum product of wind velocity and range resolutions. Several recent studies have considered the effects of amplitude noise, reduction algorithms, and possible hardware related signal artifacts on obtainable velocity accuracy. We discuss here the limitation on this accuracy resulting from the incoherent nature and finite temporal extent of backscatter from aerosols. For a lidar return from a hard (or slab) target, the phase of the intermediate frequency (IF) signal is random and the total return energy fluctuates from shot to shot due to speckle; however, the offset from the transmitted frequency is determinable with an accuracy subject only to instrumental effects and the signal to noise ratio (SNR), the noise being determined by the LO power in the shot noise limited regime. This is not the case for a return from a media extending over a range on the order of or greater than the spatial extent of the transmitted pulse, such as from atmospheric aerosols. In this case, the phase of the IF signal will exhibit a temporal random walk like behavior. It will be uncorrelated over times greater than the pulse duration as the transmitted pulse samples non-overlapping volumes of scattering centers. Frequency analysis of the IF signal in a window similar to the transmitted pulse envelope will therefore show shot-to-shot frequency deviations on the order of the inverse pulse duration reflecting the random phase rate variations. Like speckle, these deviations arise from the incoherent nature of the scattering process and diminish if the IF signal is averaged over times greater than a single range resolution cell (here the pulse duration). Apart from limiting the high SNR performance of a Doppler lidar, this shot-to-shot variance in velocity estimates has a practical impact on lidar design parameters. In high SNR operation, for example, a lidar's efficiency in obtaining mean wind measurements is determined by its repetition rate and not pulse energy or average power. In addition, this variance puts a practical limit on the shot-to-shot hard target performance required of a lidar.

  8. Influence of SMAT Parameters on Microstructural and Mechanical Properties of Al-Mg-Si Alloy AA 6061

    NASA Astrophysics Data System (ADS)

    Anand Kumar, S.; Satish Kumar, P.; Ganesh Sundara Raman, S.; Sankara Narayanan, T. S. N.

    2017-04-01

    In the present work, the influence of surface mechanical attrition treatment (SMAT) parameters on the microstructural and mechanical properties of an aluminum-magnesium-silicon alloy AA 6061 was studied using design of experiment technique. Balls of three different diameters were used, and SMAT was done for three different durations. The microstructural features of the surface layer fabricated by SMAT were characterized by cross-sectional scanning electron microscopic observations, x-ray diffraction technique and transmission electron microscopy. The microindentation hardness, nanoindentation hardness and surface roughness were determined. Due to SMAT, nanocrystallites formed on the surface and near-surface regions, and hardness and surface roughness increased. The ball diameter was the most influencing SMAT parameter compared to the treatment duration. However, interaction between ball diameter and treatment duration could not be ignored. Regression equations were developed relating the process parameters to the surface properties. The ball diameter and treatment duration could thus be properly selected as per the required values of roughness and/or the hardness.

  9. Chiral magnetic currents with QGP medium response in heavy-ion collisions at RHIC and LHC energies

    NASA Astrophysics Data System (ADS)

    She, Duan; Feng, Sheng-Qin; Zhong, Yang; Yin, Zhong-Bao

    2018-03-01

    We calculate the electromagnetic current with a more realistic approach in the RHIC and LHC energy regions in the article. We take the partons formation time as the initial time of the magnetic field response of QGP medium. The maximum electromagnetic current and the time-integrated current are two important characteristics of the chiral magnetic effect (CME), which can characterize the intensity and duration of fluctuations of CME. We consider the finite frequency response of CME to a time-varying magnetic field, find a significant impact from QGP medium feedback, and estimate the generated electromagnetic current as a function of time, beam energy and impact parameter.

  10. Nonphasematched broadband THz amplification and reshaping in a dispersive chi(3) medium.

    PubMed

    Koys, Martin; Noskovicova, Eva; Velic, Dusan; Lorenc, Dusan

    2017-06-12

    We theoretically investigate non-phasematched broadband THz amplification in dispersive chi(3) media. A short 100 fs pump pulse is interacting with a temporally matched second harmonic pulse and a weak THz signal through the four wave mixing process and a significant broadband THz amplification and reshaping is observed. The pulse evolution dynamics is explored by numerically solving a set of generalized Nonlinear Schroedinger equations. The influence of incident pulse chirp, pulse duration and the role of wavelength, THz seed frequency and losses are evaluated separately. It is found that a careful choice of incident parameters can provide a broadband THz output and/or a significant increase of THz peak power.

  11. Delayed fertilization of anuran amphibian (Xenopus) eggs leads to reduced numbers of primordial germ cells

    NASA Technical Reports Server (NTRS)

    Wakahara, M.; Neff, A. W.; Malacinski, G. M.

    1984-01-01

    Several media were tested for the extent to which they promoted high fertilization efficiencies in ovulated, stripped Xenopus eggs. One medium was selected for maintaining eggs in a 'delayed fertilization' (DelF) condition. DelF eggs displayed several unusual characteristics, including shift of the center of gravity, prominent sperm entrance site, and occasional polyspermy. The frequency of normal pattern formation varied according to the length of time eggs were maintained in the DelF condition. Various developmental abnormalities were observed during gastrulation, neurulation, and organogenesis. Most abnormalities appeared, however, to be related to morphogenesis of the endoderm. Primordial germ cell (PGC) development was examined in DelF eggs which displayed normal external morphological features at the swimming tadpole stage. PGC counts were usually normal in short-duration (eg, 5 hr) DelF eggs, but frequently substantially reduced or completely diminished in longer-duration (eg, 25h) tadpoles. Six spawnings were compared and shown to exhibit considerable variability in fertility, morphogenesis, and PGC development. Yolk platelet shifts and developmental parameters were examined in two additional spawnings. The subcortical cytoplasm in which the germ plasm is normally localized appeared to be disrupted in longer duration DelF eggs. That observation may account for low PGC counts in DelF tadpoles.

  12. On the vanishing of the t-term in the short-time expansion of the diffusion coefficient for oscillating gradients in diffusion NMR

    NASA Astrophysics Data System (ADS)

    Laun, Frederik B.; Demberg, Kerstin; Nagel, Armin M.; Uder, Micheal; Kuder, Tristan A.

    2017-11-01

    Nuclear magnetic resonance (NMR) diffusion measurements can be used to probe porous structures or biological tissues by means of the random motion of water molecules. The short-time expansion of the diffusion coefficient in powers of sqrt(t), where t is the diffusion time related to the duration of the diffusion-weighting magnetic field gradient profile, is universally connected to structural parameters of the boundaries restricting the diffusive motion. The sqrt(t)-term is proportional to the surface to volume ratio. The t-term is related to permeability and curvature. The short time expansion can be measured with two approaches in NMR-based diffusion experiments: First, by the use of diffusion encodings of short total duration and, second, by application of oscillating gradients of long total duration. For oscillating gradients, the inverse of the oscillation frequency becomes the relevant time scale. The purpose of this manuscript is to show that the oscillating gradient approach is blind to the t-term. On the one hand, this prevents fitting of permeability and curvature measures from this term. On the other hand, the t-term does not bias the determination of the sqrt(t)-term in experiments.

  13. Application of pattern recognition techniques to acousto-ultrasonic testing of Kevlar composite panels

    NASA Astrophysics Data System (ADS)

    Hinton, Yolanda L.

    An acousto-ultrasonic evaluation of panels fabricated from woven Kevlar and PVB/phenolic resin is being conducted. The panels were fabricated with various simulated defects. They were examined by pulsing with one acoustic emission sensor, and detecting the signal with another sensor, on the same side of the panel at a fixed distance. The acoustic emission signals were filtered through high (400-600 KHz), low (100-300 KHz) and wide (100-1200 KHz) bandpass filters. Acoustic emission signal parameters, including amplitude, counts, rise time, duration, 'energy', rms, and counts to peak, were recorded. These were statistically analyzed to determine which of the AE parameters best characterize the simulated defects. The wideband filtered acoustic emission signal was also digitized and recorded for further processing. Seventy-one features of the signals in both the time and frequency domains were calculated and compared to determine which subset of these features uniquely characterize the defects in the panels. The objective of the program is to develop a database of AE signal parameters and features to be used in pattern recognition as an inspection tool for material fabricated from these materials.

  14. The timbre model

    NASA Astrophysics Data System (ADS)

    Jensen, Kristoffer

    2002-11-01

    A timbre model is proposed for use in multiple applications. This model, which encompasses all voiced isolated musical instruments, has an intuitive parameter set, fixed size, and separates the sounds in dimensions akin to the timbre dimensions as proposed in timbre research. The analysis of the model parameters is fully documented, and it proposes, in particular, a method for the estimation of the difficult decay/release split-point. The main parameters of the model are the spectral envelope, the attack/release durations and relative amplitudes, and the inharmonicity and the shimmer and jitter (which provide both for the slow random variations of the frequencies and amplitudes, and also for additive noises). Some of the applications include synthesis, where a real-time application is being developed with an intuitive gui, classification, and search of sounds based on the content of the sounds, and a further understanding of acoustic musical instrument behavior. In order to present the background of the model, this presentation will start with sinusoidal A/S, some timbre perception research, then present the timbre model, show the validity for individual music instrument sounds, and finally introduce some expression additions to the model.

  15. A simulation model for predicting the temperature during the application of MR-guided focused ultrasound for stroke treatment using pulsed ultrasound

    NASA Astrophysics Data System (ADS)

    Hadjisavvas, V.; Damianou, C.

    2011-09-01

    In this paper a simulation model for predicting the temperature during the application of MR-guided focused ultrasound for stroke treatment using pulsed ultrasound is presented. A single element spherically focused transducer of 5 cm diameter, focusing at 10 cm and operating at either 0.5 MHz or 1 MHz was considered. The power field was estimated using the KZK model. The temperature was estimated using the bioheat equation. The goal was to extract the acoustic parameters (power, pulse duration, duty factor and pulse repetition frequency) that maintain a temperature increase of less than 1 °C during the application of a pulse ultrasound protocol. It was found that the temperature change increases linearly with duty factor. The higher the power, the lower the duty factor needed to keep the temperature change to the safe limit of 1 °C. The higher the frequency the lower the duty factor needed to keep the temperature change to the safe limit of 1 °C. Finally, the deeper the target, the higher the duty factor needed to keep the temperature change to the safe limit of 1 °C. The simulation model was tested in brain tissue during the application of pulse ultrasound and the measured temperature was in close agreement with the simulated temperature. This simulation model is considered to be very useful tool for providing acoustic parameters (frequency, power, duty factor, pulse repetition frequency) during the application of pulsed ultrasound at various depths in tissue so that a safe temperature is maintained during the treatment. This model could be tested soon during stroke clinical trials.

  16. Sleep and dream habits in a sample of French college students who report no sleep disorders.

    PubMed

    Vallat, Raphael; Eskinazi, Mickael; Nicolas, Alain; Ruby, Perrine

    2018-02-06

    There is a lack of up-to-date data on sleep and dream habits of college students. To fill in this gap, we used an online questionnaire sent to the student mailing lists of two major universities of Lyon (Lyon 1 and Lyon 2) for the recruitment of an functional magnetic resonance imaging study with sleep disorders as exclusion criteria. In the sample (1,137 French college students, 411 males, mean age = 22.2 ± 2.4 years, body mass index = 22.0 ± 3.2 kg m -2 ), on average, the participants reported spending about 8 hr in bed during weekdays, 9 hr during the weekends, and 90.9% of them reported no difficulty falling asleep. Less than 0.4% of students reported to have sleep-walking episodes regularly, but nearly 7% reported regular sleep-talking episodes. The average dream recall frequency was about 3 mornings per week with a dream in mind. Dream recall frequency was positively correlated with the clarity of dream content and the frequency of lucid dreaming, and was negatively correlated with age. Fourteen percent of the students reported frequent lucid dreams, and 6% reported frequent recurrent dreams. We found a gender effect for several sleep and dream parameters, including dream recall frequency and time in bed, both of which were higher in women than in men. We have also observed differences between academic disciplines, namely humanities students (Lyon 2) reported spending more time in bed than sciences students (Lyon 1). These results confirm a gender difference for several sleep and dream parameters, and suggest a link between academic disciplines and sleep duration. © 2018 European Sleep Research Society.

  17. Parametric changes in response equilibrium during an intra-cranial self stimulation (ICSS) task: can reward value be assessed independently of absolute threshold?

    PubMed

    Easterling, K W; Holtzman, S G

    1997-01-01

    Traditional ICSS methodologies have attempted to evaluate changes in the rewarding value of brain stimulation by assessing the lowest value of the stimulation that will support responding. However, orderly changes in suprathreshold indicants of hedonic magnitude such as titration point have been shown. In the present experiments, rats were trained to respond on two ICSS autotitration schedules in which every response on one lever produced stimulation of the medial forebrain bundle, and every Xth response decreased either the stimulation current or the stimulation frequency. At any time, a response on a second "reset" lever restored the stimulation current or frequency available on the stimulation lever to its starting level and operationally defined changes in "reward value". In order to study this titration point measure, two response requirements (responses/stepdown; step size) and two stimulation parameters (initial stimulation level; train duration) were systematically varied. Under both current and frequency titration schedules, data indicated that response rate and titration point remained stable over repeated trials and multiple testing days--parameters being constant. Across all conditions, compared to the frequency titration schedule, subjects responding under the current titration schedule showed significantly higher titration points and lower rates of responding. Indicating the independence of rate and titration point data, parametric manipulations did not affect titration point and rate data concurrently. Results support the conclusion that titration point is a relative measure of "reward value" that is generally independent of response rate, but that is affected by manipulations that alter the amount of stimulation available between "resets". Additional work is needed in order to determine the relationship between the magnitude of stimulation needed to maintain minimal responding and that needed to maintain response equilibrium in an autotitration task.

  18. Assessment of Time and Frequency Domain Parameters of Heart Rate Variability and Interictal Cardiac Rhythm Abnormalities in Drug-naïve Patients with Idiopathic Generalized Epilepsy

    PubMed Central

    Kilinc, Ozden; Cincin, Altug; Pehlivan, Aslihan; Midi, Ipek; Kepez, Alper; Agan, Kadriye

    2016-01-01

    Background and Purpose: Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Methods: Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Results: Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Conclusions: Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures. PMID:27390676

  19. Effects of source spatial partial coherence on temporal fade statistics of irradiance flux in free-space optical links through atmospheric turbulence.

    PubMed

    Chen, Chunyi; Yang, Huamin; Zhou, Zhou; Zhang, Weizhi; Kavehrad, Mohsen; Tong, Shoufeng; Wang, Tianshu

    2013-12-02

    The temporal covariance function of irradiance-flux fluctua-tions for Gaussian Schell-model (GSM) beams propagating in atmospheric turbulence is theoretically formulated by making use of the method of effective beam parameters. Based on this formulation, new expressions for the root-mean-square (RMS) bandwidth of the irradiance-flux temporal spectrum due to GSM beams passing through atmospheric turbulence are derived. With the help of these expressions, the temporal fade statistics of the irradiance flux in free-space optical (FSO) communication systems, using spatially partially coherent sources, impaired by atmospheric turbulence are further calculated. Results show that with a given receiver aperture size, the use of a spatially partially coherent source can reduce both the fractional fade time and average fade duration of the received light signal; however, when atmospheric turbulence grows strong, the reduction in the fractional fade time becomes insignificant for both large and small receiver apertures and in the average fade duration turns inconsiderable for small receiver apertures. It is also illustrated that if the receiver aperture size is fixed, changing the transverse correlation length of the source from a larger value to a smaller one can reduce the average fade frequency of the received light signal only when a threshold parameter in decibels greater than the critical threshold level is specified.

  20. Tremor pattern differentiates drug-induced resting tremor from Parkinson disease.

    PubMed

    Nisticò, R; Fratto, A; Vescio, B; Arabia, G; Sciacca, G; Morelli, M; Labate, A; Salsone, M; Novellino, F; Nicoletti, A; Petralia, A; Gambardella, A; Zappia, M; Quattrone, A

    2016-04-01

    DAT-SPECT, is a well-established procedure for distinguishing drug-induced parkinsonism from Parkinson's disease (PD). We investigated the usefulness of blink reflex recovery cycle (BRrc) and of electromyographic parameters of resting tremor for the differentiation of patients with drug-induced parkinsonism with resting tremor (rDIP) from those with resting tremor due to PD. This was a cross-sectional study. In 16 patients with rDIP and 18 patients with PD we analysed electrophysiological parameters (amplitude, duration, burst and pattern) of resting tremor. BRrc at interstimulus intervals (ISI) of 100, 150, 200, 300, 400, 500 and 750 msec was also analysed in patients with rDIP, patients with PD and healthy controls. All patients and controls underwent DAT-SPECT. Rest tremor amplitude was higher in PD patients than in rDIP patients (p < 0.001), while frequency and burst duration were higher in rDIP than in PD (p < 0.001, p < 0.003, respectively). Resting tremor showed a synchronous pattern in all patients with rDIP, whereas it had an alternating pattern in all PD patients (p < 0.001). DAT-SPECT was normal in rDIP patients while it was markedly abnormal in patients with PD. In the absence of DAT-SPECT, the pattern of resting tremor can be considered a useful investigation for differentiating rDIP from PD. Copyright © 2016. Published by Elsevier Ltd.

  1. Effects of Word Frequency and Transitional Probability on Word Reading Durations of Younger and Older Speakers.

    PubMed

    Moers, Cornelia; Meyer, Antje; Janse, Esther

    2017-06-01

    High-frequency units are usually processed faster than low-frequency units in language comprehension and language production. Frequency effects have been shown for words as well as word combinations. Word co-occurrence effects can be operationalized in terms of transitional probability (TP). TPs reflect how probable a word is, conditioned by its right or left neighbouring word. This corpus study investigates whether three different age groups-younger children (8-12 years), adolescents (12-18 years) and older (62-95 years) Dutch speakers-show frequency and TP context effects on spoken word durations in reading aloud, and whether age groups differ in the size of these effects. Results show consistent effects of TP on word durations for all age groups. Thus, TP seems to influence the processing of words in context, beyond the well-established effect of word frequency, across the entire age range. However, the study also indicates that age groups differ in the size of TP effects, with older adults having smaller TP effects than adolescent readers. Our results show that probabilistic reduction effects in reading aloud may at least partly stem from contextual facilitation that leads to faster reading times in skilled readers, as well as in young language learners.

  2. High-frequency envelope inversion analysis of the 2003 Tokachi-Oki, JAPAN, earthquake (Mw8.0)

    NASA Astrophysics Data System (ADS)

    Nakahara, H.

    2004-12-01

    The 2003 Tokachi-Oki earthquake (Mw 8.0) took place on September 26, 2003 at the plate interface between the subducting Pacific plate and the Hokkaido island, northern Japan. The focal depth is around 30km and the focal mechanism is thrust type. This earthquake caused 2 missings, more than 100 injures, 2000 collapsed houses, and so on. Slip distribution on the fault plane was already estimated by inversion analyses of low-frequency seismograms. However, source characteristics for the earthquake in frequencies higher than 1 Hz is not so far clarified. In this study, we execute an envelope inversion analysis based on the method by Nakahara et al. (1998) and clarify the spatial distribution of high-frequency seismic energy radiation on the fault plane of this earthquake. We use three-component sum of mean squared velocity seismograms multiplied by a density of earth medium, which is called envelopes here, for the envelope inversion analysis. Three frequency bands of 1-2, 2-4, and 4-8 Hz are adopted. We use envelopes in the time window from the onset of S waves to the lapse time of 128 sec. Green functions of envelopes representing the energy propagation process through a scattering medium are calculated based on the radiative transfer theory, which are characterized by parameters of scattering attenuation and intrinsic absorption. We use the values obtained for eastern Hokkaido (Hoshiba, 1993). We assume the fault plane as follows: strike=249o, dip=15o, rake=130o, length=150km, width=165km with reference to a waveform inversion analysis in low frequencies (e.g. Yagi, 2003). We divide this fault plane into 110 subfaults, each of which is a 15km x 15km square. Rupture velocity is assumed to be constant. Seismic energy is radiated from a point source as soon as the rupture front passes the center of each subfault. Time function of energy radiation is assumed as a box-car function. The amount of seismic energy from all the subfaults and site amplification factors for all the stations are estimated by the envelope inversion method. Rupture velocity and the duration time of a box-car function should be estimated by a grid search. Theoretical envelopes calculated with best-fit parameters generally fit to observed ones. The rupture velocity and duration time were estimated as 3.0 km/s and 6 sec, respectively. The high-frequency seismic energy was found to be radiated mainly from two spots on the fault plane: The first one is the deeper part beneath the initial rupture point and the second is the southern shallow part of the fault plane. Radiated energy was estimated to be 7.2 × 1016J in the 1-8Hz band. Acknowledgements: We used strong-motion seismograms recorded by the K-NET and KiK-net of NIED, JAPAN.

  3. Time related variations in stem cell harvesting of umbilical cord blood

    NASA Astrophysics Data System (ADS)

    Mazzoccoli, Gianluigi; Miscio, Giuseppe; Fontana, Andrea; Copetti, Massimiliano; Francavilla, Massimo; Bosi, Alberto; Perfetto, Federico; Valoriani, Alice; de Cata, Angelo; Santodirocco, Michele; Totaro, Angela; Rubino, Rosa; di Mauro, Lazzaro; Tarquini, Roberto

    2016-02-01

    Umbilical cord blood (UCB) contains hematopoietic stem cells and multipotent mesenchymal cells useful for treatment in malignant/nonmalignant hematologic-immunologic diseases and regenerative medicine. Transplantation outcome is correlated with cord blood volume (CBV), number of total nucleated cells (TNC), CD34+ progenitor cells and colony forming units in UCB donations. Several studies have addressed the role of maternal/neonatal factors associated with the hematopoietic reconstruction potential of UCB, including: gestational age, maternal parity, newborn sex and birth weight, placental weight, labor duration and mode of delivery. Few data exist regarding as to how time influences UCB collection and banking patterns. We retrospectively analyzed 17.936 cord blood donations collected from 1999 to 2011 from Tuscany and Apulia Cord Blood Banks. Results from generalized multivariable linear mixed models showed that CBV, TNC and CD34+ cell were associated with known obstetric and neonatal parameters and showed rhythmic patterns in different time domains and frequency ranges. The present findings confirm that volume, total nucleated cells and stem cells of the UCB donations are hallmarked by rhythmic patterns in different time domains and frequency ranges and suggest that temporal rhythms in addition to known obstetric and neonatal parameters influence CBV, TNC and CD34+ cell content in UBC units.

  4. Evaluation of safety and tolerance of microencapsulated Lactobacillus reuteri NCIMB 30242 in a yogurt formulation: a randomized, placebo-controlled, double-blind study.

    PubMed

    Jones, Mitchell L; Martoni, Christopher J; Tamber, Sandeep; Parent, Mathieu; Prakash, Satya

    2012-06-01

    Probiotic organisms have shown promise in treating diseases. Previously, we have reported on the efficacy of microencapsulated Lactobacillus reuteri NCIMB 30242 in a yogurt formulation at lowering serum cholesterol levels in otherwise healthy hypercholesterolemic adults. This study investigates the safety and toxicology of oral ingestion of microencapsulated L. reuteri NCIMB 30242 in a yogurt formulation. A randomized group of 120 subjects received a dose of 5 × 10(10) CFU microencapsulated L. reuteri NCIMB 30242 in yogurt (n=59) or placebo yogurt (n=61) twice/day for 6 weeks. Clinical chemistry and hematological parameters of safety were analyzed. Fecal samples were collected at these time points for the analysis of deconjugated bile acids. The frequency, duration and intensity of adverse events (AEs) and clinical significance of safety parameters were recorded for both groups. No clinically significant differences between the probiotic yogurt and placebo yogurt treated groups were detected in either the blood clinical chemistry or hematology results and there was no significant increase in fecal deconjugated bile acids (P>0.05) between treated and control groups. The frequency and intensity of AEs was similar in the two groups. These results demonstrate the safe use of this formulation in food. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Graded hypoxia acts through a network of distributed peripheral oxygen chemoreceptors to produce changes in respiratory behaviour and plasticity.

    PubMed

    Janes, Tara A; Xu, Fenglian; Syed, Naweed I

    2015-07-01

    Respiratory behaviour relies critically upon sensory feedback from peripheral oxygen chemoreceptors. During environmental or systemic hypoxia, chemoreceptor input modulates respiratory central pattern generator activity to produce reflex-based increases in respiration and also shapes respiratory plasticity over longer timescales. The best-studied oxygen chemoreceptors are undoubtedly the mammalian carotid bodies; however, questions remain regarding this complex organ's role in shaping respiration in response to varying oxygen levels. Furthermore, many taxa possess distinct oxygen chemoreceptors located within the lungs, airways and cardiovasculature, but the functional advantage of multiple chemoreceptor sites is unclear. In this study, it is demonstrated that a distributed network of peripheral oxygen chemoreceptors exists in Lymnaea stagnalis and significantly modulates aerial respiration. Specifically, Lymnaea breath frequency and duration represent parameters that are shaped by interactions between hypoxic severity and its time-course. Using a combination of behaviour and electrophysiology approaches, the chemosensory pathways underlying hypoxia-induced changes in breath frequency/duration were explored. The current findings demonstrate that breath frequency is uniquely modulated by the known osphradial ganglion oxygen chemoreceptors during moderate hypoxia, while a newly discovered area of pneumostome oxygen chemoreception serves a similar function specifically during more severe hypoxia. Together, these findings suggest that multiple oxygen chemosensory sites, each with their own sensory and modulatory properties, act synergistically to form a functionally distributed network that dynamically shapes respiration in response to changing systemic or environmental oxygen levels. These distributed networks may represent an evolutionarily conserved strategy vis-à-vis respiratory adaptability and have significant implications for the understanding of fundamental respiratory control systems. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  6. Napping and associated factors: a Japanese nationwide general population survey.

    PubMed

    Furihata, Ryuji; Kaneita, Yoshitaka; Jike, Maki; Ohida, Takashi; Uchiyama, Makoto

    2016-04-01

    The objective of this study was to investigate napping habits and their associated factors in the Japanese adult general population. The cross-sectional survey was conducted in November 2007 for subjects selected randomly from among 300 districts throughout Japan. Data from 7664 people (3527 men and 4137 women), aged 20-99 years, were analyzed. Participants completed a self-administered questionnaire on frequency and duration of napping. The percentage of responders for high-frequency napping, four or more days per week, was 21.2% among men and 17.1% among women. The percentage of responders for long-duration napping, 2 h or more per one nap, was 2.9% among men and 2.6% among women. Multivariate logistic regression analyses revealed that men, older age, smoking, insomnia symptoms, long sleep duration, excessive daytime sleepiness, and having sufficient rest obtained by sleep were positively associated with high-frequency napping, whereas alcohol drinking showed a negative association. Older age was negatively associated with long-duration napping whereas living in a large community, smoking, long sleep duration, excessive daytime sleepiness, and psychological stress showed a positive association. These findings provide important data for future studies aimed at improvement of sleep habits. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Estimation of RF energy absorbed in the brain from mobile phones in the Interphone Study.

    PubMed

    Cardis, E; Varsier, N; Bowman, J D; Deltour, I; Figuerola, J; Mann, S; Moissonnier, M; Taki, M; Vecchia, P; Villegas, R; Vrijheid, M; Wake, K; Wiart, J

    2011-09-01

    The objective of this study was to develop an estimate of a radio frequency (RF) dose as the amount of mobile phone RF energy absorbed at the location of a brain tumour, for use in the Interphone Epidemiological Study. We systematically evaluated and quantified all the main parameters thought to influence the amount of specific RF energy absorbed in the brain from mobile telephone use. For this, we identified the likely important determinants of RF specific energy absorption rate during protocol and questionnaire design, we collected information from study subjects, network operators and laboratories involved in specific energy absorption rate measurements and we studied potential modifiers of phone output through the use of software-modified phones. Data collected were analysed to assess the relative importance of the different factors, leading to the development of an algorithm to evaluate the total cumulative specific RF energy (in joules per kilogram), or dose, absorbed at a particular location in the brain. This algorithm was applied to Interphone Study subjects in five countries. The main determinants of total cumulative specific RF energy from mobile phones were communication system and frequency band, location in the brain and amount and duration of mobile phone use. Though there was substantial agreement between categorisation of subjects by cumulative specific RF energy and cumulative call time, misclassification was non-negligible, particularly at higher frequency bands. Factors such as adaptive power control (except in Code Division Multiple Access networks), discontinuous transmission and conditions of phone use were found to have a relatively minor influence on total cumulative specific RF energy. While amount and duration of use are important determinants of RF dose in the brain, their impact can be substantially modified by communication system, frequency band and location in the brain. It is important to take these into account in analyses of risk of brain tumours from RF exposure from mobile phones.

  8. Esophageal sensation in premature human neonates: temporal relationships and implications of aerodigestive reflexes and electrocortical arousals

    PubMed Central

    Parks, Vanessa N.; Peng, Juan; Dzodzomenyo, Samuel; Fernandez, Soledad; Shaker, Reza; Splaingard, Mark

    2012-01-01

    Electrocortical arousal (ECA) as an effect of visceral provocation or of its temporal relationships with aerodigestive reflexes in premature neonates is not known. We tested the hypothesis that esophageal provocation results in both esophageal reflex responses and ECAs during sleep and that ECAs are dependent on the frequency characteristics of esophageal neuromotor responses. We defined the spatiotemporal relationship of ECAs in relation to 1) spontaneous pharyngoesophageal swallow sequences and gastroesophageal reflux (GER) events and 2) sensory-motor characteristics of esophageal reflexes. Sixteen healthy premature neonates born at 27.9 ± 3.4 wk were tested at 36.8 ± 1.9 wk postmenstrual age. Ninety-five midesophageal and 31 sham stimuli were given in sleep during concurrent manometry and videopolysomnography. With stimulus onset as reference point, we scored the response latency, frequency occurrence and duration of arousals, peristaltic reflex, and upper esophageal sphincter contractile reflex (UESCR). Changes in polysomnography-respiratory patterns and esophageal sensory-motor parameters were scored by blinded observers. Significantly (for each characteristic listed, P < 0.05), swallow sequences were associated with arousals and sleep state changes, and arousals were associated with incomplete peristalsis, response delays to lower esophageal sphincter relaxation, and prolonged esophageal clearance. GER events (73.5%) provoked arousals, and arousals were associated with response delays to peristaltic reflexes or clearance, sleep state modification, and prolonged respiratory arousal. Midesophageal stimuli (54%) provoked arousals and were associated with increased frequency, prolonged latency, prolonged response duration of peristaltic reflexes and UESCR, and increased frequency of sleep state changes and respiratory arousals. In human neonates, ECAs are provoked upon esophageal stimulation; the sensory-motor characteristics of esophageal reflexes are distinct when accompanied by arousals. Aerodigestive homeostasis is defended by multiple tiers of aerodigestive safety mechanisms, and when esophageal reflexes are delayed, cortical hypervigilance (ECAs) occurs. PMID:21852361

  9. Estimation of RF energy absorbed in the brain from mobile phones in the Interphone Study

    PubMed Central

    Varsier, N; Bowman, J D; Deltour, I; Figuerola, J; Mann, S; Moissonnier, M; Taki, M; Vecchia, P; Villegas, R; Vrijheid, M; Wake, K; Wiart, J

    2011-01-01

    Objectives The objective of this study was to develop an estimate of a radio frequency (RF) dose as the amount of mobile phone RF energy absorbed at the location of a brain tumour, for use in the Interphone Epidemiological Study. Methods We systematically evaluated and quantified all the main parameters thought to influence the amount of specific RF energy absorbed in the brain from mobile telephone use. For this, we identified the likely important determinants of RF specific energy absorption rate during protocol and questionnaire design, we collected information from study subjects, network operators and laboratories involved in specific energy absorption rate measurements and we studied potential modifiers of phone output through the use of software-modified phones. Data collected were analysed to assess the relative importance of the different factors, leading to the development of an algorithm to evaluate the total cumulative specific RF energy (in joules per kilogram), or dose, absorbed at a particular location in the brain. This algorithm was applied to Interphone Study subjects in five countries. Results The main determinants of total cumulative specific RF energy from mobile phones were communication system and frequency band, location in the brain and amount and duration of mobile phone use. Though there was substantial agreement between categorisation of subjects by cumulative specific RF energy and cumulative call time, misclassification was non-negligible, particularly at higher frequency bands. Factors such as adaptive power control (except in Code Division Multiple Access networks), discontinuous transmission and conditions of phone use were found to have a relatively minor influence on total cumulative specific RF energy. Conclusions While amount and duration of use are important determinants of RF dose in the brain, their impact can be substantially modified by communication system, frequency band and location in the brain. It is important to take these into account in analyses of risk of brain tumours from RF exposure from mobile phones. PMID:21659468

  10. Detecting Slow Deformation Signals Preceding Dynamic Failure: A New Strategy For The Mitigation Of Natural Hazards (SAFER)

    NASA Astrophysics Data System (ADS)

    Vinciguerra, S.; Colombero, C.; Comina, C.; Umili, G.

    2015-12-01

    Rock slope monitoring is a major aim in territorial risk assessment and mitigation. The use of "site specific" microseismic monitoring systems can allow to detect pre-failure signals in unstable sectors within the rock mass and to predict the possible acceleration to the failure. To this aim multi-scale geophysical methods can provide a unique tool for an high-resolution imaging of the internal structure of the rock mass and constraints on the physical state of the medium. We present here a cross-hole seismic tomography survey coupled with laboratory ultrasonic velocity measurements and determination of physical properties on rock samples to characterize the damaged and potentially unstable granitic cliff of Madonna del Sasso (NW, Italy). Results allowed to achieve two main advances, in terms of obtaining: i) a lithological interpretation of the velocity field obtained at the site, ii) a systematic correlation of the measured velocities with physical properties (density and porosity) and macroscopic features of the granite (weathering and anisotropy) of the cliff. A microseismic monitoring system developed by the University of Turin/Compagnia San Paolo, consisting of a network of 4 triaxial geophones (4.5 Hz) connected to a 12-channel data logger, has been deployed on the unstable granitic cliff. More than 2000 events with different waveforms, duration and frequency content were recorded between November 2013 and July 2014. By inspecting the acquired events we identified the key parameters for a reliable distinction among the nature of each signal, i.e. the signal shape (in terms of amplitude, duration, kurtosis) and the frequency content (maximum frequency content and frequency distribution). Four main classes of recorded signals can be recognised: microseismic events, regional earthquakes, electrical noises and calibration signals, and unclassified events (probably grouping rockfalls, quarry blasts, other anthropic and natural sources of seismic noise).

  11. Effect of Solar Radiation on Viscoelastic Properties of Bovine Leather: Temperature and Frequency Scans

    NASA Astrophysics Data System (ADS)

    Nalyanya, Kallen Mulilo; Rop, Ronald K.; Onyuka, Arthur S.

    2017-04-01

    This work presents both analytical and experimental results of the effect of unfiltered natural solar radiation on the thermal and dynamic mechanical properties of Boran bovine leather at both pickling and tanning stages of preparation. Samples cut from both pickled and tanned pieces of leather of appropriate dimensions were exposed to unfiltered natural solar radiation for time intervals ranging from 0 h (non-irradiated) to 24 h. The temperature of the dynamic mechanical analyzer was equilibrated at 30°C and increased to 240°C at a heating rate of 5°C \\cdot Min^{-1}, while its oscillation frequency varied from 0.1 Hz to 100 Hz. With the help of thermal analysis (TA) control software which analyzes and generates parameter means/averages at temperature/frequency range, the graphs were created by Microsoft Excel 2013 from the means. The viscoelastic properties showed linear frequency dependence within 0.1 Hz to 30 Hz followed by negligible frequency dependence above 30 Hz. Storage modulus (E') and shear stress (σ ) increased with frequency, while loss modulus (E''), complex viscosity (η ^{*}) and dynamic shear viscosity (η) decreased linearly with frequency. The effect of solar radiation was evident as the properties increased initially from 0 h to 6 h of irradiation followed by a steady decline to a minimum at 18 h before a drastic increase to a maximum at 24 h. Hence, tanning industry can consider the time duration of 24 h for sun-drying of leather to enhance the mechanical properties and hence the quality of the leather. At frequencies higher than 30 Hz, the dynamic mechanical properties are independent of the frequency. The frequency of 30 Hz was observed to be a critical value in the behavior in the mechanical properties of bovine hide.

  12. Characterization the microstructure of pulsed Nd:YAG welding method in low frequencies; correlation with tensile and fracture behavior in laser-welded nitinol joints

    NASA Astrophysics Data System (ADS)

    Shojaei Zoeram, Ali; Rahmani, Aida; Asghar Akbari Mousavi, Seyed Ali

    2017-05-01

    The precise controllability of heat input in pulsed Nd:YAG welding method provided by two additional parameters, frequency and pulse duration, has made this method very promising for welding of alloys sensitive to heat input. The poor weldability of Ti-rich nitinol as a result of the formation of Ti2Ni IMC has deprived us of the unique properties of this alloy. In this study, to intensify solidification rate during welding of Ti-rich nitinol, pulsed Nd:YAG laser beam in low frequency was employed in addition to the employment of a copper substrate. Specific microstructure produced in this condition was characterized and the effects of this microstructure on tensile and fracture behavior of samples welded by two different procedures, full penetration and double-sided method with halved penetration depth for each side were investigated. The investigations revealed although the combination of low frequencies, the use of a high thermal conductor substrate and double-sided method eliminated intergranular fracture and increased tensile strength, the particular microstructure, built in the pulsed welding method in low frequencies, results to the formation of the longitudinal cracks during the first stages of tensile test at weld centerline. This degrades tensile strength of welded samples compared to base metal. The results showed samples welded in double-sided method performed much better than samples welded in full penetration mode.

  13. Improving the efficiency of the cardiac catheterization laboratories through understanding the stochastic behavior of the scheduled procedures.

    PubMed

    Stepaniak, Pieter S; Soliman Hamad, Mohamed A; Dekker, Lukas R C; Koolen, Jacques J

    2014-01-01

    In this study, we sought to analyze the stochastic behavior of Catherization Laboratories (Cath Labs) procedures in our institution. Statistical models may help to improve estimated case durations to support management in the cost-effective use of expensive surgical resources. We retrospectively analyzed all the procedures performed in the Cath Labs in 2012. The duration of procedures is strictly positive (larger than zero) and has mostly a large minimum duration. Because of the strictly positive character of the Cath Lab procedures, a fit of a lognormal model may be desirable. Having a minimum duration requires an estimate of the threshold (shift) parameter of the lognormal model. Therefore, the 3-parameter lognormal model is interesting. To avoid heterogeneous groups of observations, we tested every group-cardiologist-procedure combination for the normal, 2- and 3-parameter lognormal distribution. The total number of elective and emergency procedures performed was 6,393 (8,186 h). The final analysis included 6,135 procedures (7,779 h). Electrophysiology (intervention) procedures fit the 3-parameter lognormal model 86.1% (80.1%). Using Friedman test statistics, we conclude that the 3-parameter lognormal model is superior to the 2-parameter lognormal model. Furthermore, the 2-parameter lognormal is superior to the normal model. Cath Lab procedures are well-modelled by lognormal models. This information helps to improve and to refine Cath Lab schedules and hence their efficient use.

  14. Bayesian Inference of Nonstationary Precipitation Intensity-Duration-Frequency Curves for Infrastructure Design

    DTIC Science & Technology

    2016-03-01

    design . ERDC/CHL CHETN-X-2. Vicksburg, MS: U.S. Army Engineer Research and Development Center. http://chl.erdc.usace.army. mil/chetn REFERENCES...Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change, edited by S. Solomon , D. Qin, M. Manning, Z. Chen, M...Duration- Frequency Curves for Infrastructure Design by Brian E. Skahill, Amir AghaKouchak, Linyin Cheng, Aaron Byrd, and Joseph Kanney

  15. Behavioral, Psychological, and Demographic Predictors of Physical Fitness.

    DTIC Science & Technology

    1987-12-14

    calisthenics ) were assessed: (a) frequency (i.e., times per week or month an exercise was done), and (b) duration (i.e., time spent exercising during a... workout period). An exercise activity scale was computed as the sum of the frequency-by-duration cross-product for each exercise. Substance consumption... street ") (alpha =- .79). Items used in these scales were taken from health behavior questionnaires developed by Vickers and He-vig (cf. Vickers & Hervig

  16. Varying effects of geomorphic change on floodplain inundation and forest communities

    NASA Astrophysics Data System (ADS)

    Keim, R.; Johnson, E. L.; Edwards, B. L.; King, S. L.; Hupp, C. R.

    2015-12-01

    Overbank flooding in floodplains is an important control on vegetation, but effects of changing flooding are difficult to predict because sensitivities of plant communities to multidimensional flooding (frequency, depth, duration, and timing) are not well understood. We used HEC-RAS to model the changing flooding regime in the lower White River floodplain, Arkansas, in response to rapid incision of the Mississippi River in the 1930s, and quantified flood frequency, depth, and duration by forest community type. Incision has decreased flooding especially in terms of frequency, which is one of the most important variables for ecological processes. Modeled depth-duration curves varied more among floodplain reaches than among forest communities within the same reach, but forest communities are now arranged in accordance with new flood regimes in place after river incision. Forest responses to subtle geomorphic change are slower than other vegetation communities, so detection of the full ramifications of ecohydrologic change may require decades.

  17. The relationship between human behavior and the process of epidemic spreading in a real social network

    NASA Astrophysics Data System (ADS)

    Grabowski, A.; Rosińska, M.

    2012-07-01

    On the basis of experimental data on interactions between humans we have investigated the process of epidemic spreading in a social network. We found that the distribution of the number of contacts maintained in one day is exponential. Data on frequency and duration of interpersonal interactions are presented. They allow us to simulate the spread of droplet-/-air-borne infections and to investigate the influence of human dynamics on the epidemic spread. Specifically, we investigated the influence of the distribution of frequency and duration of those contacts on magnitude, epidemic threshold and peak timing of epidemics propagating in respective networks. It turns out that a large increase in the magnitude of an epidemic and a decrease in epidemic threshold are visible if and only if both are taken into account. We have found that correlation between contact frequency and duration strongly influences the effectiveness of control measures like mass immunization campaigns.

  18. High-frequency, long-duration water sampling in acid mine drainage studies: a short review of current methods and recent advances in automated water samplers

    USGS Publications Warehouse

    Chapin, Thomas

    2015-01-01

    Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.

  19. Frequency-duration analysis of dissolved-oxygen concentrations in two southwestern Wisconsin streams

    USGS Publications Warehouse

    Greb, Steven R.; Graczyk, David J.

    2007-01-01

    Historically, dissolved-oxygen (DO) data have been collected in the same manner as other water-quality constituents, typically at infrequent intervals as a grab sample or an instantaneous meter reading. Recent years have seen an increase in continuous water-quality monitoring with electronic dataloggers. This new technique requires new approaches in the statistical analysis of the continuous record. This paper presents an application of frequency-duration analysis to the continuous DO records of a cold and a warm water stream in rural southwestern Wisconsin. This method offers a quick, concise way to summarize large time-series data bases in an easily interpretable manner. Even though the two streams had similar mean DO concentrations, frequency-duration analyses showed distinct differences in their DO-concentration regime. This type of analysis also may be useful in relating DO concentrations to biological effects and in predicting low DO occurrences.

  20. Effect of extremely low frequency electromagnetic field on brain histopathology of Caspian Sea Cyprinus carpio.

    PubMed

    Samiee, Farzaneh; Samiee, Keivandokht

    2017-01-01

    There is limited research on the effect of electromagnetic field on aquatic organisms, especially freshwater fish species. This study was conducted to evaluate the effect of extremely low frequency electromagnetic field (ELF-EMF) (50 Hz) exposure on brain histopathology of Cyprinus carpio, one of the important species of Caspian Sea with significant economic value. A total of 200 healthy fish were used in this study. They were classified randomly in two groups: sham-exposed group and experimental group, which were exposed to five different magnetic field intensities (0.1, 1, 3, 5, and 7 mT) at two different exposure times (0.5 and 1 h). Histologic results indicate that exposure of C. carpio to artificial ELF-EMF caused severe histopathological changes in the brain at field intensities ≥3 mT leading to brain necrosis. Field intensity and duration of exposure were key parameters in induction of lesion in the brain. Further studies are needed to elucidate exact mechanism of EMF exposure on the brain.

Top