NASA Astrophysics Data System (ADS)
Yuanxiang, ZHOU; Zhongliu, ZHOU; Ling, ZHANG; Yunxiao, ZHANG; Yajun, MO; Jiantao, SUN
2018-05-01
For the partial discharge test of electrical equipment with large capacitance, the use of low-frequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply. However, the validity of PD test under low frequency voltage needs to be evaluated. In order to investigate the influence of voltage frequency on corona discharge in the air, the discharge test of the tip-plate electrode under the frequency from 50 to 0.1 Hz is carried out based on the impulse current method. The results show that some of the main features of corona under low frequency do not change. The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle. The magnitude of discharge and interval in positive cycle are random, while that in negative cycle are regular. With the decrease of frequency, the inception voltage increases. The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated, with discussion and interpretation from the aspects of space charge transportation, effective discharge time and transition of discharge modes. There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency. The experimental results can be the reference for mode identification of partial discharge under low frequency tests. The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency (usually 50 Hz). Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.
Robles, Guillermo; Fresno, José Manuel; Martínez-Tarifa, Juan Manuel; Ardila-Rey, Jorge Alfredo; Parrado-Hernández, Emilio
2018-03-01
The measurement of partial discharge (PD) signals in the radio frequency (RF) range has gained popularity among utilities and specialized monitoring companies in recent years. Unfortunately, in most of the occasions the data are hidden by noise and coupled interferences that hinder their interpretation and renders them useless especially in acquisition systems in the ultra high frequency (UHF) band where the signals of interest are weak. This paper is focused on a method that uses a selective spectral signal characterization to feature each signal, type of partial discharge or interferences/noise, with the power contained in the most representative frequency bands. The technique can be considered as a dimensionality reduction problem where all the energy information contained in the frequency components is condensed in a reduced number of UHF or high frequency (HF) and very high frequency (VHF) bands. In general, dimensionality reduction methods make the interpretation of results a difficult task because the inherent physical nature of the signal is lost in the process. The proposed selective spectral characterization is a preprocessing tool that facilitates further main processing. The starting point is a clustering of signals that could form the core of a PD monitoring system. Therefore, the dimensionality reduction technique should discover the best frequency bands to enhance the affinity between signals in the same cluster and the differences between signals in different clusters. This is done maximizing the minimum Mahalanobis distance between clusters using particle swarm optimization (PSO). The tool is tested with three sets of experimental signals to demonstrate its capabilities in separating noise and PDs with low signal-to-noise ratio and separating different types of partial discharges measured in the UHF and HF/VHF bands.
Ardila-Rey, Jorge Alfredo; Montaña, Johny; de Castro, Bruno Albuquerque; Schurch, Roger; Covolan Ulson, José Alfredo; Muhammad-Sukki, Firdaus; Bani, Nurul Aini
2018-03-29
Partial discharges (PDs) are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power cables. Generally, the classical phase-resolved partial discharge (PRPD) patterns are used to perform the identification of the type of PD source when they are related to a specific degradation process and when the electrical noise level is low compared to the magnitudes of the PD signals. However, in practical applications such as measurements carried out in the field or in industrial environments, several PD sources and large noise signals are usually present simultaneously. In this study, three different inductive sensors have been used to evaluate and compare their performance in the detection and separation of multiple PD sources by applying the chromatic technique to each of the measured signals.
Ardila-Rey, Jorge Alfredo; Montaña, Johny; Schurch, Roger; Covolan Ulson, José Alfredo; Bani, Nurul Aini
2018-01-01
Partial discharges (PDs) are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power cables. Generally, the classical phase-resolved partial discharge (PRPD) patterns are used to perform the identification of the type of PD source when they are related to a specific degradation process and when the electrical noise level is low compared to the magnitudes of the PD signals. However, in practical applications such as measurements carried out in the field or in industrial environments, several PD sources and large noise signals are usually present simultaneously. In this study, three different inductive sensors have been used to evaluate and compare their performance in the detection and separation of multiple PD sources by applying the chromatic technique to each of the measured signals. PMID:29596337
Shoulder replacement - discharge
Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - ...
Development of Partial Discharging Simulation Test Equipment
NASA Astrophysics Data System (ADS)
Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu
2017-12-01
In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.
Partial Discharge Ultrasound Detection Using the Sagnac Interferometer System
Li, Xiaomin; Gao, Yan; Zhang, Hongjuan; Wang, Dong; Jin, Baoquan
2018-01-01
Partial discharge detection is crucial for electrical cable safety evaluation. The ultrasonic signals frequently generated in the partial discharge process contains important characteristic information. However, traditional ultrasonic transducers are easily subject to strong electromagnetic interference in environments with high voltages and strong magnetic fields. In order to overcome this problem, an optical fiber Sagnac interferometer system is proposed for partial discharge ultrasound detection. Optical fiber sensing and time-frequency analysis of the ultrasonic signals excited by the piezoelectric ultrasonic transducer is realized for the first time. The effective frequency band of the Sagnac interferometer system was up to 175 kHz with the help of a designed 10 kV partial discharge simulator device. Using the cumulative histogram method, the characteristic ultrasonic frequency band of the partial discharges was between 28.9 kHz and 57.6 kHz for this optical fiber partial discharge detection system. This new ultrasound sensor can be used as an ideal ultrasonic source for the intrinsically safe detection of partial discharges in an explosive environment. PMID:29734682
NASA Astrophysics Data System (ADS)
Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.
2017-12-01
The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.
NASA Astrophysics Data System (ADS)
Maqueo, P. D. G.; Maier, M.; Evans, M. D. G.; Coulombe, S.; Bergthorson, J. M.
2018-04-01
The operation of a nanosecond repetitively pulsed discharge for partial oxidation of CH4 is characterized at atmospheric pressure and room temperature. Two regimes are observed: diffuse and filamentary. The first is a low power regime, characterized by low rotational temperatures around 400 K. The second is much more energetic with rotational temperatures close to 600 K. Both have vibrational temperatures of at least 10 times their rotational temperatures. The average electron number density was determined to be 8.9×1015 and 4.0×1017 cm-3, respectively, showing an increase in the ionization fraction in the more powerful filamentary regime. Results of CH4 conversion to H2, CO, CO2 and C2H6 are presented for the filamentary regime, while the diffuse regime shows no measurable conversion ability. As expected, oxidative mixtures show higher conversion ability than pure CH4. A maximum conversion efficiency of 26.3% and a maximum energy efficiency of 19.7% were reached for the oxidative mixtures.
NASA Astrophysics Data System (ADS)
Sarathi, R.; Giridhar, A. V.; Sethupathi, K.
2010-01-01
Liquid nitrogen (LN 2) is used as an insulant as well as coolant in high temperature superconducting power equipments. Particle contamination in liquid nitrogen is one of the major cause for formation of partial discharges during operation. An attempt has been made in the present study to understand the feasibility of using Ultra High Frequency (UHF) sensors for identification of partial discharge (PD) formed due to particle movement in liquid nitrogen under AC voltages. It is observed that the partial discharge formed in LN 2 radiates UHF signal. The results of the study indicate that the conventional partial discharge measurement and UHF peak amplitude measurement have direct correlation. The Phase Resolved Partial Discharge (PRPD) analysis indicates that the partial discharge formed due to particle movement occurs in the entire phase windows of the AC voltage. The PD magnitude increases with increase in applied voltage. The frequency content of UHF signal generated due to particle movement in liquid nitrogen under AC voltages lies in the range of 0.5-1.5 GHz. The UHF sensor output signal analyzed using spectrum analyzer by operating it in zero-span mode, indicates that burst type PD occurs due to particle movement.
Design of a fast computer-based partial discharge diagnostic system
NASA Technical Reports Server (NTRS)
Oliva, Jose R.; Karady, G. G.; Domitz, Stan
1991-01-01
Partial discharges cause progressive deterioration of insulating materials working in high voltage conditions and may lead ultimately to insulator failure. Experimental findings indicate that deterioration increases with the number of discharges and is consequently proportional to the magnitude and frequency of the applied voltage. In order to obtain a better understanding of the mechanisms of deterioration produced by partial discharges, instrumentation capable of individual pulse resolution is required. A new computer-based partial discharge detection system was designed and constructed to conduct long duration tests on sample capacitors. This system is capable of recording large number of pulses without dead time and producing valuable information related to amplitude, polarity, and charge content of the discharges. The operation of the system is automatic and no human supervision is required during the testing stage. Ceramic capacitors were tested at high voltage in long duration tests. The obtained results indicated that the charge content of partial discharges shift towards high levels of charge as the level of deterioration in the capacitor increases.
Auto-Detection of Partial Discharges in Power Cables by Descrete Wavelet Transform
NASA Astrophysics Data System (ADS)
Yasuda, Yoh; Hara, Takehisa; Urano, Koji; Chen, Min
One of the serious problems that may happen in power XLPE cables is destruction of insulator. The best and conventional way to prevent such a crucial accident is generally supposed to ascertain partial corona discharges occurring at small void in organic insulator. However, there are some difficulties to detect those partial discharges because of existence of external noises in detected data, whose patterns are hardly identified at a glance. By the reason of the problem, there have been a number of researches on the way of development to accomplish detecting partial discharges by employing neural network (NN) system, which is widely known as the system for pattern recognition. We have been developing the NN system of the auto-detection for partial discharges, which we actually input numerical data of waveform itself into and obtained appropriate performance from. In this paper, we employed Descrete Wavelet Transform (DWT) to acquire more detailed transformed data in order to put them into the NN system. Employing DWT, we became able to express the waveform data in time-frequency space, and achieved effective detectiton of partial discharges by NN system. We present here the results using DWT analysis for partial discharges and noise signals which we obtained actually. Moreover, we present results out of the NN system which were dealt with those transformed data.
Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors
Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José
2016-01-01
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique. PMID:27517931
Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.
Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José
2016-08-10
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.
Wavelet transform processing applied to partial discharge evaluation
NASA Astrophysics Data System (ADS)
Macedo, E. C. T.; Araújo, D. B.; da Costa, E. G.; Freire, R. C. S.; Lopes, W. T. A.; Torres, I. S. M.; de Souza Neto, J. M. R.; Bhatti, S. A.; Glover, I. A.
2012-05-01
Partial Discharge (PD) is characterized by high frequency current pulses that occur in high voltage (HV) electrical equipments originated from gas ionization process when damaged insulation is submitted to high values of electric field [1]. PD monitoring is a useful method of assessing the aging degree of the insulation, manufacturing defects or chemical/mechanical damage. Many sources of noise (e.g. radio transmissions, commutator noise from rotating machines, power electronics switching circuits, corona discharge, etc.) can directly affect the PD estimation. Among the many mathematical techniques that can be applied to de-noise PD signals, the wavelet transform is one of the most powerful. It can simultaneously supply information about the pulse occurrence, time and pulse spectrum, and also de-noise in-field measured PD signals. In this paper is described the application of wavelet transform in the suppression of the main types of noise that can affect the observation and analysis of PD signals in high voltage apparatus. In addition, is presented a study that indicates the appropriated mother-wavelet for this application based on the cross-correlation factor.
Partial discharge testing of bulk transformer oil
NASA Astrophysics Data System (ADS)
Rohwein, G. J.
The generation of partial discharges in bulk transformer oil was investigated experimentally to determine the dominant conditions which contribute to their formation and growth under repetitive impulse stresses. The motivation for conducting these experiments arose from a problem with partial discharges and breakdowns occurring in the insulating oil around the high voltage switch in a continuous running 1.5 MV repetitive pulser system. From the experiment it was found tht repetitive stressing caused low level field ionization around the electrodes which led to bubble formation and eventually partial discharges. There were also qualitative indications of charge accumulation in the oil. Photographic records of numerous shot sequences were used to study the phenomena.
Transformer partial discharge monitoring based on optical fiber sensing
NASA Astrophysics Data System (ADS)
Wang, Kun; Tong, Xinglin; Zhu, Xiaolong
2014-06-01
The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the optical fiber sensing technology, we have done some research on fiber optics Fabry-Perot (FP) sensing which can be useful for the transformer on online partial discharge monitoring. This research aimed at improving the reliability of power system safety monitoring. We have done some work as follows: designing a set for fiber optics FP sensor preparation, according to the fabrication procedure strictly making out the sensors, building a reasonable signal demodulation system for fiber optics FP sensing, doing a preliminary analysis about online partial discharge signal monitoring, including the research on different discharge intensities with the same measuring distance and different measuring distances with the same discharge intensity, and then making a detailed analysis of the experimental results.
System for Measuring Conditional Amplitude, Phase, or Time Distributions of Pulsating Phenomena
Van Brunt, Richard J.; Cernyar, Eric W.
1992-01-01
A detailed description is given of an electronic stochastic analyzer for use with direct “real-time” measurements of the conditional distributions needed for a complete stochastic characterization of pulsating phenomena that can be represented as random point processes. The measurement system described here is designed to reveal and quantify effects of pulse-to-pulse or phase-to-phase memory propagation. The unraveling of memory effects is required so that the physical basis for observed statistical properties of pulsating phenomena can be understood. The individual unique circuit components that comprise the system and the combinations of these components for various measurements, are thoroughly documented. The system has been applied to the measurement of pulsating partial discharges generated by applying alternating or constant voltage to a discharge gap. Examples are shown of data obtained for conditional and unconditional amplitude, time interval, and phase-of-occurrence distributions of partial-discharge pulses. The results unequivocally show the existence of significant memory effects as indicated, for example, by the observations that the most probable amplitudes and phases-of-occurrence of discharge pulses depend on the amplitudes and/or phases of the preceding pulses. Sources of error and fundamental limitations of the present measurement approach are analyzed. Possible extensions of the method are also discussed. PMID:28053450
Parts, Materials, and Processes Control Program for Expendable Launch Vehicles
2015-07-31
burn-in, electrical tests (DWV, room and hot IR, partial discharge when in corona region); perform DPA with SEM/EDX analysis of dielectric...life test; x-ray and vicinal illumination inspection; electrical tests (DWV, room and hot IR, partial discharge when in corona region) Termination...defects; proper voltage derating. Partial discharge testing, corona inception testing up to 60% of rated voltage; CSAM screening; voltage burn
Dynamics of multiple double layers in high pressure glow discharge in a simple torus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar Paul, Manash, E-mail: manashkr@gmail.com; Sharma, P. K.; Thakur, A.
2014-06-15
Parametric characterization of multiple double layers is done during high pressure glow discharge in a toroidal vessel of small aspect ratio. Although glow discharge (without magnetic field) is known to be independent of device geometry, but the toroidal boundary conditions are conducive to plasma growth and eventually the plasma occupy the toroidal volume partially. At higher anode potential, the visibly glowing spots on the body of spatially extended anode transform into multiple intensely luminous spherical plasma blob structures attached to the tip of the positive electrode. Dynamics of multiple double layers are observed in argon glow discharge plasma in presencemore » of toroidal magnetic field. The radial profiles of plasma parameters measured at various toroidal locations show signatures of double layer formation in our system. Parametric dependence of double layer dynamics in presence of toroidal magnetic field is presented here.« less
NASA Astrophysics Data System (ADS)
Li, Yanran; Chen, Duo; Li, Li; Zhang, Jiwei; Li, Guang; Liu, Hongxia
2017-11-01
GIS (gas insulated switchgear), is an important equipment in power system. Partial discharge plays an important role in detecting the insulation performance of GIS. UHF method and ultrasonic method frequently used in partial discharge (PD) detection for GIS. However, few studies have been conducted on comparison of this two methods. From the view point of safety, it is necessary to investigate UHF method and ultrasonic method for partial discharge in GIS. This paper presents study aimed at clarifying the effect of UHF method and ultrasonic method for partial discharge caused by free metal particles in GIS. Partial discharge tests were performed in laboratory simulated environment. Obtained results show the ability of anti-interference of signal detection and the accuracy of fault localization for UHF method and ultrasonic method. A new method based on UHF method and ultrasonic method of PD detection for GIS is proposed in order to greatly enhance the ability of anti-interference of signal detection and the accuracy of detection localization.
Parts, Materials, and Processes Control Program for Expendable Launch Vehicles
2015-05-21
CSAM, thermal shock, voltage burn-in, electrical tests (DWV, room and hot IR, partial discharge when in corona region); perform DPA with SEM/EDX...controls to eliminate dielectric defects; proper voltage derating. Partial discharge testing, corona inception testing up to 60% of rated voltage...voltage burn-in; DWV; room and hot IR; life test; partial discharge when in corona region B-7 Table B-5. Metallized Plastic Capacitors
Kane, Thomas G.; Bauer, David J.; Martinez, Clair M.
1994-01-01
Streamflow and precipitation data collected at and near Yucca Mountain, Nevada, during water years 1986-90 are presented in this report. The data were collected and compiled as part of the studies by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, to characterize surface-water hydrology in the Yucca Mountain area. Streamflow data include daily-mean discharges and peak discharges at 5 continuous-record gaging stations, and peak discharges at 10 crest-stage, partial-record stations and 2 miscellaneous sites. Precipitation data include cumulative totals at 20 stations maintained by the U.S. Geological Survey and daily totals at 15 stations maintained by the Weather Service Nuclear Support Office, National Oceanic and Atmospheric Administration.
Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers
Ren, Ming; Song, Bo; Dong, Ming
2017-01-01
Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring. PMID:29125544
Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers.
Ren, Ming; Zhou, Jierui; Song, Bo; Zhang, Chongxing; Dong, Ming; Albarracín, Ricardo
2017-11-10
Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring.
Partial and no recovery from delirium after hospital discharge predict increased adverse events.
Cole, Martin G; McCusker, Jane; Bailey, Robert; Bonnycastle, Michael; Fung, Shek; Ciampi, Antonio; Belzile, Eric
2017-01-08
The implications of partial and no recovery from delirium after hospital discharge are not clear. We sought to explore whether partial and no recovery from delirium among recently discharged patients predicted increased adverse events (emergency room visits, hospitalisations, death) during the subsequent 3 months. Prospective study of recovery from delirium in older hospital inpatients. The Confusion Assessment Method was used to diagnose delirium in hospital and determine recovery status after discharge (T0). Adverse events were determined during the 3 months T0. Survival analysis to the first adverse event and counting process modelling for one or more adverse events were used to examine associations between recovery status (ordinal variable, 0, 1 or 2 for full, partial or no recovery, respectively) and adverse events. Of 278 hospital inpatients with delirium, 172 were discharged before the assessment of recovery status (T0). Delirium recovery status at T0 was determined for 152: 25 had full recovery, 32 had partial recovery and 95 had no recovery. Forty-four patients had at least one adverse event during the subsequent 3 months. In multivariable analysis of one or more adverse events, poorer recovery status predicted increased adverse events; the hazard ratio (HR) (95% confidence interval, CI) was 1.72 (1.09, 2.71). The association of recovery status with adverse events was stronger among patients without dementia. Partial and no recovery from delirium after hospital discharge appear to predict increased adverse events during the subsequent 3 months These findings have potentially important implications for in-hospital and post-discharge management and policy.
NASA Astrophysics Data System (ADS)
Dan, C.; Morar, R.
2017-05-01
Working methods for on site testing of insulations: Gas chromatography (using the TFGA-P200 chromatographer); Electrical measurements of partial discharge levels using the digital detection, recording, analysis and partial discharge acquisition system, MPD600. First performed, between 2000-2015, were the chromatographic analyses concerning electrical insulating environments of: 102 current transformers, 110kV. Items in operation, functioning in 110/20kV substations. 38 voltage transformers, 110kV also in operation, functioning in 110/20kV substations. Then, electrical measurements of partial discharge inside instrument transformers, on site (power substations) were made (starting in the year 2009, over a 7-year period, collecting data until the year 2015) according to the provisions of standard EN 61869-1:2007 „Instrument transformers. General requirements”, applying, assimilated to it, type A partial discharge test procedure, using as test voltage the very rated 110kV distribution grid voltage. Given the results of two parallel measurements, containing: to this type of failure specific gas amount (H 2) and the quantitative partial discharge’ level, establishing a clear dependence between the quantity of partial discharges and the type and amount of in oil dissolved gases inside equipments affected by this type of defect: partial discharges, was expected. Of the „population” of instrument transformers subject of the two parallel measurements, the dependency between Q IEC (apparent charge) and (H 2) (hydrogen, gas amount dissolved within their insulating environment) represents a finite assemblage situated between the two limits developed on an empirical basis.
Ardila-Rey, Jorge Alfredo; Rojas-Moreno, Mónica Victoria; Martínez-Tarifa, Juan Manuel; Robles, Guillermo
2014-02-19
Partial discharge (PD) detection is a standardized technique to qualify electrical insulation in machines and power cables. Several techniques that analyze the waveform of the pulses have been proposed to discriminate noise from PD activity. Among them, spectral power ratio representation shows great flexibility in the separation of the sources of PD. Mapping spectral power ratios in two-dimensional plots leads to clusters of points which group pulses with similar characteristics. The position in the map depends on the nature of the partial discharge, the setup and the frequency response of the sensors. If these clusters are clearly separated, the subsequent task of identifying the source of the discharge is straightforward so the distance between clusters can be a figure of merit to suggest the best option for PD recognition. In this paper, two inductive sensors with different frequency responses to pulsed signals, a high frequency current transformer and an inductive loop sensor, are analyzed to test their performance in detecting and separating the sources of partial discharges.
NASA Technical Reports Server (NTRS)
Bever, R. S.
1984-01-01
Nondestructive high voltage test techniques (mostly electrical methods) are studied to prevent total or catastrophic breakdown of insulation systems under applied high voltage in space. Emphasis is on the phenomenon of partial breakdown or partial discharge (P.D.) as a symptom of insulation quality, notably partial discharge testing under D.C. applied voltage. Many of the electronic parts and high voltage instruments in space experience D.C. applied stress in service, and application of A.C. voltage to any portion thereof would be prohibited. Suggestions include: investigation of the ramp test method for D.C. partial discharge measurements; testing of actual flight-type insulation specimen; perfect plotting resin samples with controlled defects for test; several types of plotting resins and recommendations of the better ones from the electrical characteristics; thermal and elastic properties are also considered; testing of commercial capaciters; and approximate acceptance/rejection/rerating criteria for sample test elements for space use, based on D.C. partial discharge.
Izzati, Wan Akmal; Arief, Yanuar Z; Adzis, Zuraimy; Shafanizam, Mohd
2014-01-01
Polymer nanocomposites have recently been attracting attention among researchers in electrical insulating applications from energy storage to power delivery. However, partial discharge has always been a predecessor to major faults and problems in this field. In addition, there is a lot more to explore, as neither the partial discharge characteristic in nanocomposites nor their electrical properties are clearly understood. By adding a small amount of weight percentage (wt%) of nanofillers, the physical, mechanical, and electrical properties of polymers can be greatly enhanced. For instance, nanofillers in nanocomposites such as silica (SiO2), alumina (Al2O3) and titania (TiO2) play a big role in providing a good approach to increasing the dielectric breakdown strength and partial discharge resistance of nanocomposites. Such polymer nanocomposites will be reviewed thoroughly in this paper, with the different experimental and analytical techniques used in previous studies. This paper also provides an academic review about partial discharge in polymer nanocomposites used as electrical insulating material from previous research, covering aspects of preparation, characteristics of the nanocomposite based on experimental works, application in power systems, methods and techniques of experiment and analysis, and future trends.
Thyroid gland removal - discharge
... tingling in your face or lips Alternative Names Total thyroidectomy - discharge; Partial thyroidectomy - discharge; Thyroidectomy - discharge; Subtotal thyroidectomy - discharge References Lai SY, Mandel SJ, Weber RS. Management of thyroid neoplasms. In: Flint PW, Haughey BH, ...
Sánchez-Rodríguez, Judith; Zugasti, Alejandro; Santamaría, Abel; Galván-Arzate, Sonia; Segura-Puertas, Lourdes
2006-08-01
In the sea anemone Bartholomea annulata, four different types of cnidocysts, basitrichous isorhizas, microbasic p-mastigophores, microbasic amastigophores and spirocysts were identified. In relation to the efficacy of different substances to induce discharge of nematocysts we observe that distilled water induced more than 70% of microbasic p-mastigophores to discharge, whereas spirocysts were discharged in a lesser extent (approximately 20%). The median lethal dose (LD50) in mice was found after injection of 700.7 mg protein per kg of body weight from the crude extract. The protein with neurotoxic effect was isolated using low-pressure liquid chromatography. The neurotoxic activity was determined using sea crabs (Ocypode quadrata), injecting 15 microg of crude extract or isolated fraction into the third walking leg, and violent motor activity followed by progressive loss of sensibility to external stimuli, further leading to full paralysis were observed. The active fraction (called V) eluted at 43.9 min.
Accelerated aging test results for aerospace wire insulation constructions
NASA Technical Reports Server (NTRS)
Dunbar, William G.
1995-01-01
Several wire insulation constructions were evaluated with and without continuous glow discharges at low pressure and high temperature to determine the aging characteristics of acceptable wire insulation constructions. It was known at the beginning of the test program that insulation aging takes several years when operated at normal ambient temperature and pressure of 20 C and 760 torr. Likewise, it was known that the accelerated aging process decreases insulation life by approximately 50% for each 10 C temperature rise. Therefore, the first phases of the program, not reported in these test results, were to select wire insulation constructions that could operate at high temperature and low pressure for over 10,000 hours with negligible shrinkage and little materials' deterioration.The final phase of the program was to determine accelerated aging characteristics. When an insulation construction is subjected to partial discharges the insulation is locally heated by the bombardment of the discharges, the insulation is also subjected to ozone and other deteriorating gas particles that may significantly increase the aging process. Several insulation systems using either a single material or combinations of teflon, kapton, and glass insulation constructions were tested. All constructions were rated to be partial discharge and/or corona-free at 240 volts, 400 Hz and 260 C (500 F) for 50, 000 hours at altitudes equivalent to the Paschen law. Minimum partial discharge aging tests were preceded by screening tests lasting 20 hours at 260 C. The aging process was accelerated by subjecting the test articles to temperatures up to 370 C (700 F) with and without partial discharges. After one month operation with continuous glow discharges surrounding the test articles, most insulation systems were either destroyed or became brittle, cracked, and unsafe for use. Time with space radiation as with partial discharges is accumulative.
Accelerated aging test results for aerospace wire insulation constructions
NASA Astrophysics Data System (ADS)
Dunbar, William G.
1995-11-01
Several wire insulation constructions were evaluated with and without continuous glow discharges at low pressure and high temperature to determine the aging characteristics of acceptable wire insulation constructions. It was known at the beginning of the test program that insulation aging takes several years when operated at normal ambient temperature and pressure of 20 C and 760 torr. Likewise, it was known that the accelerated aging process decreases insulation life by approximately 50% for each 10 C temperature rise. Therefore, the first phases of the program, not reported in these test results, were to select wire insulation constructions that could operate at high temperature and low pressure for over 10,000 hours with negligible shrinkage and little materials' deterioration.The final phase of the program was to determine accelerated aging characteristics. When an insulation construction is subjected to partial discharges the insulation is locally heated by the bombardment of the discharges, the insulation is also subjected to ozone and other deteriorating gas particles that may significantly increase the aging process. Several insulation systems using either a single material or combinations of teflon, kapton, and glass insulation constructions were tested. All constructions were rated to be partial discharge and/or corona-free at 240 volts, 400 Hz and 260 C (500 F) for 50, 000 hours at altitudes equivalent to the Paschen law. Minimum partial discharge aging tests were preceded by screening tests lasting 20 hours at 260 C. The aging process was accelerated by subjecting the test articles to temperatures up to 370 C (700 F) with and without partial discharges. After one month operation with continuous glow discharges surrounding the test articles, most insulation systems were either destroyed or became brittle, cracked, and unsafe for use. Time with space radiation as with partial discharges is accumulative.
Ardila-Rey, Jorge Alfredo; Rojas-Moreno, Mónica Victoria; Martínez-Tarifa, Juan Manuel; Robles, Guillermo
2014-01-01
Partial discharge (PD) detection is a standardized technique to qualify electrical insulation in machines and power cables. Several techniques that analyze the waveform of the pulses have been proposed to discriminate noise from PD activity. Among them, spectral power ratio representation shows great flexibility in the separation of the sources of PD. Mapping spectral power ratios in two-dimensional plots leads to clusters of points which group pulses with similar characteristics. The position in the map depends on the nature of the partial discharge, the setup and the frequency response of the sensors. If these clusters are clearly separated, the subsequent task of identifying the source of the discharge is straightforward so the distance between clusters can be a figure of merit to suggest the best option for PD recognition. In this paper, two inductive sensors with different frequency responses to pulsed signals, a high frequency current transformer and an inductive loop sensor, are analyzed to test their performance in detecting and separating the sources of partial discharges. PMID:24556674
Izzati, Wan Akmal; Adzis, Zuraimy; Shafanizam, Mohd
2014-01-01
Polymer nanocomposites have recently been attracting attention among researchers in electrical insulating applications from energy storage to power delivery. However, partial discharge has always been a predecessor to major faults and problems in this field. In addition, there is a lot more to explore, as neither the partial discharge characteristic in nanocomposites nor their electrical properties are clearly understood. By adding a small amount of weight percentage (wt%) of nanofillers, the physical, mechanical, and electrical properties of polymers can be greatly enhanced. For instance, nanofillers in nanocomposites such as silica (SiO2), alumina (Al2O3) and titania (TiO2) play a big role in providing a good approach to increasing the dielectric breakdown strength and partial discharge resistance of nanocomposites. Such polymer nanocomposites will be reviewed thoroughly in this paper, with the different experimental and analytical techniques used in previous studies. This paper also provides an academic review about partial discharge in polymer nanocomposites used as electrical insulating material from previous research, covering aspects of preparation, characteristics of the nanocomposite based on experimental works, application in power systems, methods and techniques of experiment and analysis, and future trends. PMID:24558326
Wang, Xiaohua; Li, Xi; Rong, Mingzhe; Xie, Dingli; Ding, Dan; Wang, Zhixiang
2017-01-01
The ultra-high frequency (UHF) method is widely used in insulation condition assessment. However, UHF signal processing algorithms are complicated and the size of the result is large, which hinders extracting features and recognizing partial discharge (PD) patterns. This article investigated the chromatic methodology that is novel in PD detection. The principle of chromatic methodologies in color science are introduced. The chromatic processing represents UHF signals sparsely. The UHF signals obtained from PD experiments were processed using chromatic methodology and characterized by three parameters in chromatic space (H, L, and S representing dominant wavelength, signal strength, and saturation, respectively). The features of the UHF signals were studied hierarchically. The results showed that the chromatic parameters were consistent with conventional frequency domain parameters. The global chromatic parameters can be used to distinguish UHF signals acquired by different sensors, and they reveal the propagation properties of the UHF signal in the L-shaped gas-insulated switchgear (GIS). Finally, typical PD defect patterns had been recognized by using novel chromatic parameters in an actual GIS tank and good performance of recognition was achieved. PMID:28106806
Wang, Xiaohua; Li, Xi; Rong, Mingzhe; Xie, Dingli; Ding, Dan; Wang, Zhixiang
2017-01-18
The ultra-high frequency (UHF) method is widely used in insulation condition assessment. However, UHF signal processing algorithms are complicated and the size of the result is large, which hinders extracting features and recognizing partial discharge (PD) patterns. This article investigated the chromatic methodology that is novel in PD detection. The principle of chromatic methodologies in color science are introduced. The chromatic processing represents UHF signals sparsely. The UHF signals obtained from PD experiments were processed using chromatic methodology and characterized by three parameters in chromatic space ( H , L , and S representing dominant wavelength, signal strength, and saturation, respectively). The features of the UHF signals were studied hierarchically. The results showed that the chromatic parameters were consistent with conventional frequency domain parameters. The global chromatic parameters can be used to distinguish UHF signals acquired by different sensors, and they reveal the propagation properties of the UHF signal in the L-shaped gas-insulated switchgear (GIS). Finally, typical PD defect patterns had been recognized by using novel chromatic parameters in an actual GIS tank and good performance of recognition was achieved.
NASA Astrophysics Data System (ADS)
Li, Yanran; Chen, Duo; Zhang, Jiwei; Chen, Ning; Li, Xiaoqi; Gong, Xiaojing
2017-09-01
GIS (gas insulated switchgear), is an important equipment in power system. Partial discharge plays an important role in detecting the insulation performance of GIS. UHF method and ultrasonic method frequently used in partial discharge (PD) detection for GIS. It is necessary to investigate UHF method and ultrasonic method for partial discharge in GIS. However, very few studies have been conducted on the method combined this two methods. From the view point of safety, a new method based on UHF method and ultrasonic method of PD detection for GIS is proposed in order to greatly enhance the ability of anti-interference of signal detection and the accuracy of fault localization. This paper presents study aimed at clarifying the effect of the new method combined UHF method and ultrasonic method. Partial discharge tests were performed in laboratory simulated environment. Obtained results show the ability of anti-interference of signal detection and the accuracy of fault localization for this new method combined UHF method and ultrasonic method.
Partial discharge detection and analysis in low pressure environments
NASA Astrophysics Data System (ADS)
Liu, Xin
Typical aerospace vehicles (aircraft and spacecraft) experience a wide range of operating pressures during ascending and returning to earth. Compared to the sea-level atmospheric pressure (760 Torr), the pressure at about 60 km altitude is 2 Torr. The performance of the electric power system components of the aerospace vehicles must remain reliable even under such sub-atmospheric operating conditions. It is well known that the dielectric strength of gaseous insulators, while the electrode arrangement remains unchanged, is pressure dependent. Therefore, characterization of the performance and behavior of the electrical insulation in flight vehicles in low-pressure environments is extremely important. Partial discharge testing is one of the practical methods for evaluating the integrity of electrical insulation in aerospace vehicles. This dissertation describes partial discharge (PD) measurements performed mainly with 60 Hz ac energization in air, argon and helium, for pressures between 2 and 760 Torr. Two main electrode arrangements were used. One was a needle-plane electrode arrangement with a Teflon insulating barrier. The other one was a twisted pair of insulated conductors taken from a standard aircraft wiring harness. The measurement results are presented in terms of typical PD current pulse waveforms and waveform analysis for both main electrode arrangements. The evaluation criteria are the waveform polarity, magnitude, shape, rise time, and phase angle (temporal location) relative to the source voltage. Two-variable histograms and statistical averages of the PD parameters are presented. The PD physical mechanisms are analyzed. For PD pattern recognition, both statistical methods (such as discharge parameter dot pattern representation, discharge parameter phase distribution, statistical operator calculations, and PD fingerprint development) and wavelet transform applications are investigated. The main conclusions of the dissertation include: (1) The PD current pulse waveforms are dependent on the pressure. (2) The rise time of the waveform is another effective PD current pulse characteristic indicator. (3) PD fingerprint patterns that are already available for atmospheric pressure (760 Torr) conditions are inadequate for the evaluation of PD pulses at low pressures. (4) Various wavelet transform techniques can be used effectively for PD pulse signal denoising purposes, and for PD pulse waveform transient feature recognition.
Critical analysis of partial discharge dynamics in air filled spherical voids
NASA Astrophysics Data System (ADS)
Callender, G.; Golosnoy, I. O.; Rapisarda, P.; Lewin, P. L.
2018-03-01
In this paper partial discharge (PD) is investigated inside a spherical air filled void at atmospheric pressure using a drift diffusion model. Discharge dynamics consisted of an electron avalanche transitioning into positive streamer, in agreement with earlier work on dielectric barrier discharges. Different model configurations were utilised to test many of the concepts employed in semi-analytical PD activity models, which use simplistic descriptions of the discharge dynamics. The results showed that many of these concepts may be erroneous, with significant discrepancies between the canonical reasoning and the simulation results. For example, the residual electric field, the electric field after a discharge, is significantly lower than the estimates used by classical PD activity models in the literature.
Advanced high frequency partial discharge measuring system
NASA Technical Reports Server (NTRS)
Karady, George G.
1994-01-01
This report explains the Advanced Partial Discharge Measuring System in ASU's High Voltage Laboratory and presents some of the results obtained using the setup. While in operation an insulation is subjected to wide ranging temperature and voltage stresses. Hence, it is necessary to study the effect of temperature on the behavior of partial discharges in an insulation. The setup described in this report can be used to test samples at temperatures ranging from -50 C to 200 C. The aim of conducting the tests described herein is to be able to predict the behavior of an insulation under different operating conditions in addition to being able to predict the possibility of failure.
Weingarten, Toby N; Del Mundo, Serena B; Yeoh, Tze Yeng; Scavonetto, Federica; Leibovich, Bradley C; Sprung, Juraj
2014-10-01
The aim of this retrospective study is to test the hypothesis that the use of spinal analgesia shortens the length of hospital stay after partial nephrectomy. We reviewed all patients undergoing partial nephrectomy for malignancy through flank incision between January 1, 2008, and June 30, 2011. We excluded patients who underwent tumor thrombectomy, used sustained-release opioids, or had general anesthesia supplemented by epidural analgesia. Patients were grouped into "spinal" (intrathecal opioid injection for postoperative analgesia) versus "general anesthetic" group, and "early" discharge group (within 3 postoperative days) versus "late" group. Association between demographics, patient physical status, anesthetic techniques, and surgical complexity and hospital stay were analyzed using multivariable logistic regression analysis. Of 380 patients, 158 (41.6%) were discharged "early" and 151 (39.7%) were "spinal" cases. Both spinal and early discharge groups had better postoperative pain control and used less postoperative systemic opioids. Spinal analgesia was associated with early hospital discharge, odds ratio 1.52, (95% confidence interval 1.00-2.30), P = 0.05, but in adjusted analysis was no longer associated with early discharge, 1.16 (0.73-1.86), P = 0.52. Early discharge was associated with calendar year, with more recent years being associated with early discharge. Spinal analgesia combined with general anesthesia was associated with improved postoperative pain control during the 1(st) postoperative day, but not with shorter hospital stay following partial nephrectomy. Therefore, unaccounted practice changes that occurred during more recent times affected hospital stay.
Anticipating electrical breakdown in dielectric elastomer actuators
NASA Astrophysics Data System (ADS)
Muffoletto, Daniel P.; Burke, Kevin M.; Zirnheld, Jennifer L.
2013-04-01
The output strain of a dielectric elastomer actuator is directly proportional to the square of its applied electric field. However, since the likelihood of electric breakdown is elevated with an increased applied field, the maximum operating electric field of the dielectric elastomer is significantly derated in systems employing these actuators so that failure due to breakdown remains unlikely even as the material ages. In an effort to ascertain the dielectric strength so that stronger electric fields can be applied, partial discharge testing is used to assess the health of the actuator by detecting the charge that is released when localized instances of breakdown partially bridge the insulator. Pre-stretched and unstretched samples of VHB4910 tape were submerged in dielectric oil to remove external sources of partial discharges during testing, and the partial discharge patterns were recorded just before failure of the dielectric sample.
Abdel Aziz, Karim; Elamin, Mohammed H; El-Saadouni, Nisrin M; El-Gabry, Dina Aly; Barakat, Mahmoud; Alhayyas, Fatima; Moselhy, Hamdy F
2016-12-01
Many patients suffering from psychosis are nonadherent to their medications. Nonadherence can range from treatment refusal to irregular use or partial change in daily medication doses. To investigate whether symptom dimensions, post-discharge care plans and being involved with faith healer affect the adherence to treatment in patients with schizophrenia. A total of 121 patients with schizophrenia were examined 6 weeks post-discharge from the inpatient unit and assessed for full, partial or nonadherence to medication. There was a significant association between family involvement and partial adherence and between community team involvement post-discharge and full adherence to medications. Psycho-education was a predictor for adherence to medications, persecutory delusions and lack of insight predicted partial adherence, while being involved with faith healers predicted nonadherence. Adherence to medications and socio-demographic variables are independent. This study demonstrated that nonadherence or partial adherence to medications is associated with lack of insight and persecutory delusions. Psycho-education could improve the adherence to medication compliances. © The Author(s) 2016.
Chun, Yang H; Ro, Jin Y
2009-01-01
Extracellular single unit recording experiments were performed to examine response characteristics of wide dynamic range neurons in the Vc that receive masseter afferent input in Sprague Dawley rats. Capsaicin, or its vehicle, was directly administered into the masseter muscle and changes in resting discharge, responses to mechanical stimulation on the cutaneous receptive field and the electrical threshold for masseter nerve stimulation were assessed. Intramuscular capsaicin induced significant increase in the background discharge and mechanical hypersensitivity to the cutaneous stimulation and lowered the threshold masseter nerve stimulation evoked responses in the majority of neurons. The capsaicin-induced increase in evoked responses, but not the resting discharge, was partially attenuated when the muscle was pretreated with a mGluR antagonist. The present study suggests that injury or inflammation in the masseter muscle induce generalized hyperexcitability of central trigeminal neurons and that the blockade of peripherally localized mGluR5 can effectively attenuate muscular hypersensitivity. PMID:19818833
A Modular Approach for Teaching Partial Discharge Phenomenon through Experiment
ERIC Educational Resources Information Center
Chatterjee, B.; Dey, D.; Chakravorti, S.
2011-01-01
Partial discharge (PD) monitoring is an effective predictive maintenance tool for electrical power equipment. As a result, an understanding of the theory related to PD and the associated measurement techniques is now necessary knowledge for power engineers in their professional life. This paper presents a modular course on PD phenomenon in which…
Partial discharge measurements on 110kV current transformers. Setting the control value. Case study
NASA Astrophysics Data System (ADS)
Dan, C.; Morar, R.
2017-05-01
The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).
DC partial discharge/environmental test screening of space TWTS
NASA Astrophysics Data System (ADS)
Hai, F.; Paschen, K. W.
Direct-current partial discharge/environmental tests are being conducted on traveling wave tubes (TWTs) designated for long-term space operation to screen out tubes with high voltage defects. Two types of TWTs with different external high-voltage insulation are being examined: (1) TWTs with polymeric potting, and (2) TWTs with ceramic feedthroughs. Detection of high voltage defects in the form of cracks and seprations in potted systems is enhanced by combining dc partial discharge testing with environmental (temperature and pressure) testing. These defects are usually caused by high stresses in the potting produced during temperature excursions by the difference in thermal expansion between the potting material and the confining ceramic-metal structure. Tests of all-ceramic-insulated TWTs indicate that the high voltage problem is internal to the vacuum envelope and requires both leakage and discharge measurements for diagnosis. This problem appears to be field emission from contaminated surfaces.
Weingarten, Toby N.; Del Mundo, Serena B.; Yeoh, Tze Yeng; Scavonetto, Federica; Leibovich, Bradley C.; Sprung, Juraj
2014-01-01
Background: The aim of this retrospective study is to test the hypothesis that the use of spinal analgesia shortens the length of hospital stay after partial nephrectomy. Materials and Methods: We reviewed all patients undergoing partial nephrectomy for malignancy through flank incision between January 1, 2008, and June 30, 2011. We excluded patients who underwent tumor thrombectomy, used sustained-release opioids, or had general anesthesia supplemented by epidural analgesia. Patients were grouped into “spinal” (intrathecal opioid injection for postoperative analgesia) versus “general anesthetic” group, and “early” discharge group (within 3 postoperative days) versus “late” group. Association between demographics, patient physical status, anesthetic techniques, and surgical complexity and hospital stay were analyzed using multivariable logistic regression analysis. Results: Of 380 patients, 158 (41.6%) were discharged “early” and 151 (39.7%) were “spinal” cases. Both spinal and early discharge groups had better postoperative pain control and used less postoperative systemic opioids. Spinal analgesia was associated with early hospital discharge, odds ratio 1.52, (95% confidence interval 1.00-2.30), P = 0.05, but in adjusted analysis was no longer associated with early discharge, 1.16 (0.73-1.86), P = 0.52. Early discharge was associated with calendar year, with more recent years being associated with early discharge. Conclusion: Spinal analgesia combined with general anesthesia was associated with improved postoperative pain control during the 1st postoperative day, but not with shorter hospital stay following partial nephrectomy. Therefore, unaccounted practice changes that occurred during more recent times affected hospital stay. PMID:25422611
Glow discharge sources for atomic and molecular analyses
NASA Astrophysics Data System (ADS)
Storey, Andrew Patrick
Two types of glow discharges were used and characterized for chemical analysis. The flowing atmospheric pressure afterglow (FAPA) source, based on a helium glow discharge (GD), was utilized to analyze samples with molecular mass spectrometry. A second GD, operated at reduced pressure in argon, was employed to map the elemental composition of a solid surface with novel optical detection systems, enabling new applications and perspectives for GD emission spectrometry. Like many plasma-based ambient desorption-ionization sources being used around the world, the FAPA requires a supply of helium to operate effectively. With increased pressures on global helium supply and pricing, the use of an interrupted stream of helium for analysis was explored for vapor and solid samples. In addition to the mass spectra generated by the FAPA source, schlieren imaging and infrared thermography were employed to map the behavior of the source and its surroundings under the altered conditions. Additionally, a new annular microplasma variation of the FAPA source was developed and characterized. A spectroscopic imaging system that utilized an adjustable-tilt interference filter was used to map the elemental composition of a sample surface by glow discharge emission spectroscopy. This apparatus was compared to other GD imaging techniques for mapping elemental surface composition. The wide bandpass filter resulted in significant spectral interferences that could be partially overcome with chemometric data processing. Because time-resolved GD emission spectroscopy can provide fine depth-profiling measurements, a natural extension of GD imaging would be its application to three-dimensional characterization of samples. However, the simultaneous cathodic sputtering that occur across the sample results in a sampling process that is not completely predictable. These issues are frequently encountered when laterally varied samples are explored with glow discharge imaging techniques. These insights are described with respect to their consequences for both imaging and conventional GD spectroscopic techniques.
ERIC Educational Resources Information Center
Karmakar, Subrata
2017-01-01
Online monitoring of high-voltage (HV) equipment is a vital tool for early detection of insulation failure. Most insulation failures are caused by partial discharges (PDs) inside the HV equipment. Because of the very high cost of establishing HV equipment facility and the limitations of electromagnetic interference-screened laboratories, only a…
NASA Astrophysics Data System (ADS)
Haţiegan, C.; Răduca, E.; Popescu, C.; Hamat, C. O.; Băra, A.; Anghel, D.; Pîrşan, D. A.
2018-01-01
The paper presents a determining and evaluating method from an experimental point of view of the partial discharges level from the insulation of the stator of a synchronous hydro-generator of high power that appear at different temperatures. The temperature is measured directly on the coil with placed thermo-resistant elements between the superior and inferior bars. Also, the level of partial discharges with the coil age in a cold state, at the temperature level of the surrounding environment from within the stator, but also in a warm state at different temperatures, is measured. Through this method there is created the possibility of highlighting some eventual degradations of the coil insulation of a hydro-generator.
NASA Astrophysics Data System (ADS)
McLachlan, R. L.; Ogston, A. S.; Allison, M. A.; Hilmo, R. S.
2016-12-01
Widely varying ratios of marine to freshwater influence within near-mouth distributaries have impacts on sedimentary processes within the lower river that have yet to be thoroughly characterized. These impacts are of particular interest because river gauging stations are often above the river-estuary interface and, therefore, may not accurately characterize sediment flux through the lower river. Flow velocity, salinity, and suspended sediment properties (concentration, particle size, and settling velocity) were measured within the tidal Sông Hu distributary of the lower Mekong River, Vietnam during both high and low river discharge seasons. Seasonal variations in river discharge and estuarine regime resulted in export of fine sediment when discharge was high ( 1.7 t s-1) and import when discharge was low ( 0.25 t s-1). Generally, the estuary moved in and out of 40 km of the lower distributary with discharge and tidal phase, and the estuary exhibited salt wedge to partially-mixed conditions. High river discharge and neap tides increased stratification of salinity and suspended sediment. Suspended sediment was influenced by seasonal and tidal fluctuations in near-bed shear stress and the intermittent presence of a protective salt wedge and associated estuary turbidity maximum. This fluctuating flow and salinity regime induced variations in flocculation, settling, and trapping of sediment within the river channel. Above the estuary, particles were pre-flocculated, and within and near the estuary, increased flocculation promoted particle settling. The degree of aggregation and settling velocity of suspended particles were largest during ebb tides of high river discharge and during flood tides of low river discharge. Sediment deposited on the river bed was protected from resuspension by lowered bed stress within and near the salt wedge. These patterns promote retention of mud in the lower river when estuarine processes exist and mud export when fluvial processes dominate. The spectrum of present conditions analyzed collaboratively with field studies, remotely sensed observations, and modeling has shed light on how this environment, and other large tropical deltas, will react to changing magnitudes of fluvial and marine influences due to sea-level rise and anthropogenic alterations to the delta.
NASA Astrophysics Data System (ADS)
Kavitha, A.; Kannan, R.; Gunasekhar, K. R.; Rajashabala, S.
2017-10-01
Amorphous titanium nitride (TiN) thin films have been prepared on silicon (Si) and glass substrates by direct-current (DC) reactive magnetron sputtering with a supported discharge (triode). Nitrogen gas (N2) at partial pressure of 0.3 Pa, 0.4 Pa, 0.5 Pa, and 0.6 Pa was used to prepare the TiN thin films, maintaining total pressure of argon and N2 of about 0.7 Pa. The chemical, microstructural, optical, and electrical properties of the TiN thin films were systematically studied. Presence of different phases of Ti with nitrogen (N), oxygen (O2), and carbon (C) elements was revealed by x-ray photoelectron spectroscopy characterization. Increase in the nitrogen pressure from 0.3 Pa to 0.6 Pa reduced the optical bandgap of the TiN thin film from 2.9 eV to 2.7 eV. Photoluminescence study showed that TiN thin film deposited at N2 partial pressure of 0.3 Pa exhibited three shoulder peaks at 330 nm, 335 nm, and 340 nm, which disappeared when the sample was deposited with N2 partial pressure of 0.6 Pa. Increase in the nitrogen content decreased the electrical resistivity of the TiN thin film from 3200 μΩ cm to 1800 μΩ cm. Atomic force microscopy studies of the TiN thin films deposited with N2 partial pressure of 0.6 Pa showed a uniform surface pattern associated with accumulation of fine grains. The results and advantages of this method of preparing TiN thin films are also reported.
Appropriate VTE prophylaxis is associated with lower direct medical costs.
Amin, Alpesh; Hussein, Mohamed; Battleman, David; Lin, Jay; Stemkowski, Stephen; Merli, Geno J
2010-11-01
To calculate and compare the direct medical costs of guideline-recommended prophylaxis with prophylaxis that does not fully adhere with guideline recommendations in a large, real-world population. Discharge records were retrieved from the US Premier Perspective™ database (January 2003-December 2003) for patients aged≥40 years with a primary diagnosis of cancer, chronic heart failure, lung disease, or severe infectious disease who received some form of thromboprophylaxis. Univariate analysis and multivariate regression modeling were performed to compare direct medical costs between discharges who received appropriate prophylaxis (correct type, dose, and duration based on sixth edition American College of Chest Physicians [ACCP] recommendations) and partial prophylaxis (not in full accordance with ACCP recommendations). Market segmentation analysis was used to compare costs stratified by hospital and patient characteristics. Of the 683 005 discharges included, 148,171 (21.7%) received appropriate prophylaxis and 534,834 (78.3%) received partial prophylaxis. The total direct unadjusted costs were $15,439 in the appropriate prophylaxis group and $17,763 in the partial prophylaxis group. After adjustment, mean adjusted total costs per discharge were lower for those receiving appropriate prophylaxis ($11,713; 95% confidence interval [CI], $11,675-$11,753) compared with partial prophylaxis ($13,369; 95% CI, $13,332-$13 406; P<0.01). Appropriate prophylaxis appeared to be associated with numerically lower unadjusted costs than partial prophylaxis, regardless of hospital size, rural/urban location, teaching status, and patient age and gender. This large, real-world analysis suggests that appropriate prophylaxis, in adherence with ACCP guidelines, is potentially cost-saving compared with partial prophylaxis in at-risk medical patients.
Detection of Partial Discharge Sources Using UHF Sensors and Blind Signal Separation
Boya, Carlos; Parrado-Hernández, Emilio
2017-01-01
The measurement of the emitted electromagnetic energy in the UHF region of the spectrum allows the detection of partial discharges and, thus, the on-line monitoring of the condition of the insulation of electrical equipment. Unfortunately, determining the affected asset is difficult when there are several simultaneous insulation defects. This paper proposes the use of an independent component analysis (ICA) algorithm to separate the signals coming from different partial discharge (PD) sources. The performance of the algorithm has been tested using UHF signals generated by test objects. The results are validated by two automatic classification techniques: support vector machines and similarity with class mean. Both methods corroborate the suitability of the algorithm to separate the signals emitted by each PD source even when they are generated by the same type of insulation defect. PMID:29140267
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-24
... Pollutant Discharge Elimination System (AgPDES) program pursuant to Section 402(b) of the Clean Water Act... Discharge Elimination System (NPDES) permit program under Section 402(n)(3) of the Act for all discharges of... through Friday, excluding legal holidays, at EPA Region 6, 1445 Ross Ave., Dallas, Texas 75202. A copy of...
NASA Astrophysics Data System (ADS)
Yasuoka, Shigekazu; Ishida, Jun; Kishida, Kyosuke; Inui, Haruyuki
2017-04-01
The influence of Ce addition on the phase constitution, microstructure, hydrogen absorption/desorption properties and battery performances of newly developed rare earth (RE)-Mg-Ni hydrogen-absorbing superlattice alloys for negative electrode materials in Ni-metal hydride (MH) batteries were investigated. The partial substitution of RE (La and Nd) with Ce results in a higher discharge performance and a lower cycle life in the battery. The Ce addition greatly affects the phase constitution, which is mainly characterized by increased formation of the AB2 phase (A = RE or Mg and B = Ni or Al). The existence of the AB2 phase is found to accelerate alloy pulverization and oxidation when the alloys are used as negative electrode materials in Ni-MH model cells. The accelerated pulverization and oxidation are considered to be responsible for the observed higher discharge performance and lower cycle life in the batteries, respectively.
NASA Astrophysics Data System (ADS)
Gadkari, Siddharth; Gu, Sai
2018-06-01
A two-dimensional numerical fluid model is developed for studying the influence of packing configurations on dielectric barrier discharge (DBD) characteristics. Discharge current profiles and time averaged electric field strength, electron number density, and electron temperature distributions are compared for the three DBD configurations, plain DBD with no packing, partially packed DBD, and fully packed DBD. The results show that a strong change in discharge behaviour occurs when a DBD is fully packed as compared to partial packing or no packing. While the average electric field strength and electron temperature of a fully packed DBD are higher relative to the other DBD configurations, the average electron density is substantially lower and may impede the DBD reactor performance under certain operating conditions. Possible scenarios of the synergistic effect of the combination of plasma with catalysis are also discussed.
Thongprayoon, Charat; Cheungpasitporn, Wisit; Srivali, Narat; Kittanamongkolchai, Wonngarm; Sakhuja, Ankit; Greason, Kevin L; Kashani, Kianoush B
2017-01-01
This study aimed to examine the association between renal recovery status at hospital discharge after acute kidney injury (AKI) and long-term mortality following transcatheter aortic valve replacement (TAVR). We screened all adult patients who survived to hospital discharge after TAVR for aortic stenosis at a quaternary referral medical center from January 1, 2008, through June 30, 2014. An AKI was defined as an increase in serum creatinine level of 0.3 mg/dL or a relative increase of 50% from baseline. Renal outcome at the time of discharge was evaluated by comparing the discharge serum creatinine level to the baseline level. Complete renal recovery was defined as no AKI at discharge, whereas partial renal recovery was defined as AKI without a need for renal replacement therapy at discharge. No renal recovery was defined as a need for renal replacement therapy at discharge. The study included 374 patients. Ninty-eight (26%) patients developed AKI during hospitalization: 55 (56%) had complete recovery; 39 (40%), partial recovery; and 4 (4%), no recovery. AKI development was significantly associated with increased risk of 2-year mortality (hazard ratio [HR], 2.20 [95% CI, 1.37-3.49]). For patients with AKI, the 2-year mortality rate for complete recovery was 34%; for partial recovery, 43%; and for no recovery, 75%; compared with 20% for patients without AKI (P < .001). In adjusted analysis, complete recovery (HR, 1.87 [95% CI, 1.03-3.23]); partial recovery (HR, 2.65 [95% CI, 1.40-4.71]) and no recovery (HR, 10.95 [95% CI, 2.59-31.49]) after AKI vs no AKI were significantly associated with increased risk of 2-year mortality. The mortality rate increased for all patients with AKI undergoing TAVR. A reverse correlation existed for progressively higher risk of death and the extent of AKI recovery.
NASA Astrophysics Data System (ADS)
Kim, Y. G.; Kim, J. C.; Kim, J. M.; Yoo, B. H.; Hwang, D. Y.; Lee, H. G.
2018-06-01
This study investigates the feasibility of using the partial insulation winding technique for the development of a self-protective MgB2 MRI magnet with a fast charge-discharge rate. Charge-discharge and quench tests for a prototype PI MgB2 magnet confirmed that the magnet was successfully operated at full-field performance and exhibited self-protecting behavior in the event of a quench. Nonetheless, the required time to charge the 0.5-T/300-mm PI MgB2 magnet was almost five days, implying that the charge-discharge delay of the PI MgB2 magnet still needs to be ameliorated further to develop a real-scale MgB2 MRI magnet with a fast charge-discharge rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shin, D.S.; Han, M.K.; Lee, J.H.
1996-12-31
In this paper, the authors have investigated effects of the arrangement of the voids in LDPE samples on PD characteristics, such as phase-related magnitude of PD, number of discharges. The differences of the PD patterns may be attributed to the arrangements of the voids. They have also employed available statistical operators, such as discharge factor and cross correlation factor in order to analyze the PD characteristics. The authors could conclude that partial discharge characteristics show quite different patterns due to the arrangements of voids in spite of the same size. The experimental results suggest that it is important to knowmore » the arrangements of the multiple voids as well as to obtain the information about the number of defects in the insulators.« less
Improved Li/BCX (thionyl chloride) cells for space applications
NASA Technical Reports Server (NTRS)
Clark, W. D. K.; Ebel, S. J.; Eberhard, D. P.; Takeuchi, E. S.
1988-01-01
New NASA requirements for the screening of lithium cells for space applications involve thermal soaks at elevated temperatures (149 C). The BCX DD and C size cells have been redesigned to pass this test with only marginal losses in capacity as was done previously for the D cells. In addition, the pressure increases in cells subjected to this high temperature environment have been characterized showing that the earlier designs failed this exposure due to lack of void volume. An improve BCX chemistry has been demonstrated which significantly improves voltage delay problems encountered after partial discharge and storage of the cells.
Partial discharge testing under direct voltage conditions
NASA Technical Reports Server (NTRS)
Bever, R. S.; Westrom, J. L.
1982-01-01
DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelerated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.
Posada-Roman, Julio; Garcia-Souto, Jose A.; Rubio-Serrano, Jesus
2012-01-01
A fiber optic interferometric sensor with an intrinsic transducer along a length of the fiber is presented for ultrasound measurements of the acoustic emission from partial discharges inside oil-filled power apparatus. The sensor is designed for high sensitivity measurements in a harsh electromagnetic field environment, with wide temperature changes and immersion in oil. It allows enough sensitivity for the application, for which the acoustic pressure is in the range of units of Pa at a frequency of 150 kHz. In addition, the accessibility to the sensing region is guaranteed by immune fiber-optic cables and the optical phase sensor output. The sensor design is a compact and rugged coil of fiber. In addition to a complete calibration, the in-situ results show that two types of partial discharges are measured through their acoustic emissions with the sensor immersed in oil. PMID:22666058
Measuring the degradation level of polymer films subjected to partial discharges
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bozzo, R.; Gemme, C.; Guastavino, F.
1996-12-31
Polymer films have been subjected to partial discharge (PD) aging. It is shown that statistical quantities derived from partial discharges patterns can be related to test conditions, film characteristics and degradation level. PDs have been measured by means of a digital system. Several resulting PD patterns have been elaborated and about 50 derived and statistical quantities have been obtained for each pattern. The effects of the test conditions on the derived quantities has been studied with relevance to the following items: To recognize the kind of film under test; to correlate the value of quantities with the degradation level ofmore » the film (i.e., to focus at the quantities which change with time); to find a link between the quantities values and the test ambient conditions (i.e., relative humidity); to determine the influence of the film thickness; and to evidence the effect of the voltage level.« less
NASA Astrophysics Data System (ADS)
Turba, Tomasz; Frącz, Paweł
2017-10-01
The paper presents results of a comparative analysis of parameters of two kinds of solid dielectrics used in air insulation systems to prevent occurring partial discharges. The research works regarded materials made of: cellulose pressboard and aramid paper. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage until breakdown occurred in the inhomogeneous environment that was simulated using needle-plate (made of copper) electrode system. The main contribution which resulted from studies is a statement that potential use of aramid paper as a dielectric can extend the life of a high voltage electric device as compared to standard cellulose pressboard usage due to higher electric resistances to breakdown or detection of corona voltage. Results shown that the aramid paper has greater electric resistance to breakdown in comparison to cellulose with no difference between both on detecting corona of partial discharge.
Flight Termination Systems Commonality Standard
2014-09-01
input level is increased 60 dB from threshold. Corona : A visible electric discharge resulting from a partial electric breakdown of gases as the...4-49 Figure 4-10. Electrostatic Discharge Test...check channel telemetry output (EFTR) CDR critical design review CFS flight self- discharge in amp-hrs CR remaining capacity for determining
NASA Astrophysics Data System (ADS)
Yin, Zelin; Zhang, Ruirui; Tong, Jie; Chen, Xi
2013-12-01
Partial discharges (PDs) are an electrical phenomenon that occurs within a transformer whenever the voltage stress is sufficient to produce ionization in voids or inclusions within a solid dielectric, at conductor/dielectric interfaces, or in bubbles within liquid dielectrics such as oil; high-frequency transient current discharges will then appear repeatedly and will progressively deteriorate the insulation, ultimately leading to breakdown. Fiber sensor has great potential on the partial discharge detection in high-voltage equipment for its immunity to electromagnetic interference and it can take direct measurement in the high voltage equipment. The energy released in PDs produces a number of effects, resulting in flash, chemical and structural changes and electromagnetic emissions and so on. Acoustic PD detection is based on the mechanical pressure wave emitted from the discharge and fluorescent fiber PD detection is based on the emitted light produced by ionization, excitation and recombination processes during the discharge. Both of the two methods have the shortage of weak anti-interference capacity in the physical environment, like thunder or other sound source. In order to avoid the false report, an all-fiber combined PD detection system of the two methods is developed in this paper. In the system the fluorescent fiber PD sensor is considered as a reference signal, three F-P based PD detection sensors are used to both monitor the PD intensity and calculate the exact position of the discharge source. Considering the wave band of the F-P cavity and the fluorescent probe are quite different, the reflection spectrum of the F-P cavity is in the infrared region, however the fluorescent probe is about 600nm to 700nm, thus the F-P sensor and fluorescent fiber probe can be connected in one fiber and the reflection light can be detected by two different detectors without mutual interference. The all-fiber partial discharge monitoring system not only can detect the PDs but also can ensure the position of the PD source and is of great anti-interference capacity in harsh environment.
Water Resources Data, New Jersey, Water Year 2002, Volume 1. Surface-Water Data
Reed, T.J.; White, B.T.; Centinaro, G.L.; Dudek, J.F.; Spehar, A.B.; Protz, A.R.; Shvanda, J.C.; Watson, A.F.; Holzer, G.K.
2003-01-01
Water-resources data for the 2002 Water Year for New Jersey are presented in three volumes, and consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground water. Volume 1 contains discharge records for 93 gaging stations; tide summaries at 31 gaging stations; and stage and contents at 39 lakes and reservoirs. Also included are stage and discharge for 104 crest-stage partial-record stations and stage-only at 31 tidal crest-stage gages. Locations of these sites are shown in figures 8-11. Additional water data were collected at various sites that are not part of the systematic data-collection program. Discharge measurements were made at 201 low-flow partial-record stations and 121 miscellaneous sites.
Electrodeless discharge lamp is easily started, has high stability
NASA Technical Reports Server (NTRS)
Bell, W. E.; Bloom, A. L.
1966-01-01
Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.
NASA Astrophysics Data System (ADS)
Kanazawa, Seiji; Enokizono, Masato; Shibakita, Toshihide; Umehara, Eiji; Toshimitsu, Jun; Ninomiya, Shinji; Taniguchi, Hideki; Abe, Yukari
In recent years, inverter drive machines such as a hybrid vehicle and an electric vehicle are operated under high voltage pulse with high repetition rate. In this case, inverter surge is generated and affected the machine operation. Especially, the enameled wire of a motor is deteriorated due to the partial discharge (PD) and finally breakdown of the wire will occur. In order to investigate a PD on a resistant enameled wire, characteristics of PD in the twisted pair sample under bipolar repetitive impulse voltages are investigated experimentally. The relationship between the applied voltage and discharge current was measured at PD inception and extinction, and we estimated the repetitive PD inception and extinction voltages experimentally. The corresponding optical emission of the discharge was also observed by using an ICCD camera. Furthermore, ozone concentration due to the discharge was measured during the life-time test of the resistant enameled wires from a working environmental point of view.
Sensitivity Testing of the NSTAR Ion Thruster
NASA Technical Reports Server (NTRS)
Sengupta, Anita; Anderson, John; Brophy, John
2007-01-01
During the Extended Life Test of the DS1 flight spare ion thruster, the engine was subjected to sensitvity testing in order to characterize the macroscopic dependence of discharge chamber sensitivity to a +\\-3% vatiation in main flow, cathode flow and beam current, and to +\\5% variation in beam and accelerator voltage, was determined for the minimum- (THO), half- (TH8) and full power (TH15) throttle levels. For each power level investigared, 16 high/low operating conditions were chosen to vary the flows, beam current, and grid voltages in in a matrix that mapped out the entire parameter space. The matrix of data generated was used to determine the partial derivative or senitivity of the dependent parameters--discharge voltage, discharge current, discharge loss, double-to-single-ion current ratio, and neutralizer-keeper voltage--to the variation in the independent parameters--main flow, cathode flow, beam current, and beam voltage. The sensititivities of each dependent parameter with respect to each independent parameter were determined using a least-square fit routine. Variation in these sensitivities with thruster runtime was recorded over the duration of the ELT, to detemine if discharge performance changed with thruster wear. Several key findings have been ascertained from the sensitivity testing. Discharge operation is most sensitve to changes in cathode flow and to a lesser degree main flow. The data also confirms that for the NSTAR configuration plasma production is limited by primary electron input due to the fixed neutral population. Key sensitivities along with their change with thruster wear (operating time) will be presented. In addition double ion content measurements with an ExB probe will also be presented to illustrate beam ion production and content sensitivity to the discharge chamber operating parameteres.
The recalculation of the original pulse produced by a partial discharge
NASA Technical Reports Server (NTRS)
Tanasescu, F.
1978-01-01
The loads on a dielectric or an insulation arrangement cannot be precisely rated without properly assessing the manner in which a pulse produced by a partial discharge is transmitted from the point of the event to the point where it is recorded. A number of analytical and graphic methods are presented, and computer simulations are used for specific cases of a few measurement circuits. It turns out to be possible to determine the effect of each circuit element and thus make some valid corrections.
Effects of Electrical Insulation Breakdown Voltage And Partial Discharge
NASA Astrophysics Data System (ADS)
Bahrim, F. S.; Rahman, N. F. A.; Haris, H. C. M.; Salim, N. A.
2018-03-01
During the last few decades, development of new materials using composite materials has been of much interest. The Cross-linked Polyethylene (XLPE) which is insulated power cables has been widely used. This paper describes the theoretical analysis, fundamental experiments and application experiments for the XLPE cable insulation. The composite that has been tested is a commercial XLPE and Polypropylene with 30% fiber glass. The results of breakdown strength and partial discharge (PD) behavior described the insulating performance of the composite.
DISCHARGE AND DEPTH BEHIND A PARTIALLY BREACHED DAM.
Chen, Cheng-lung
1987-01-01
The role that the velocity-distribution correction factor plays in the determination of the flood discharge and corresponding flow depth behind a partially breached dam is investigated. Assumption of a uniformly progressive flow for an established dam-break flood in a rectangular channel of infinite extent leads to the formulation of a theoretical relation between the depth and velocity of flow expressed in differential form. Integrating this ordinary differential equation, one can express the velocity in terms of the depth.
Determination of the “NiOOH” charge and discharge mechanisms at ideal activity
Merrill, Matthew; Worsley, Marcus; Wittstock, Arne; ...
2014-01-24
Here, optimization of electrodeposition conditions produced Ni(OH) 2 deposits chargeable up to 1.84 ± 0.02 e – per Ni on and the resulting nickel oxide/hydroxide active material could subsequently deliver 1.58 ± 0.02 e – per Ni ion (462 mA h/g) over a potential range <0.2 V. The ability of the “NiOOH” active material to deliver an approximately ideal charge and discharge facilitated a coulometric and thermodynamic analysis through which the charge/discharge mechanisms were determined from known enthalpies of formation. The (dis)charge states were confirmed with in situ Raman spectroscopy. The mechanisms were additionally evaluated with respect to pH andmore » potential dependence, charge quantities, hysteresis, and fluoride ion partial inhibition of the charge mechanism. The results indicate that the “NiOOH” (dis)charges as a solid-state system with mechanisms consistent with known nickel and oxygen redox reactions. A defect chemistry mechanism known for the LiNiO 2 system also occurs for “NiOOH” to cause both high activity and hysteresis. Similar to other cation insertion nickel oxides, the activity of the “NiOOH” mechanism is predominantly due to oxygen redox activity and does not involve the Ni4 + oxidation state. The “NiOOH” was produced from cathodic electrodeposition of Ni(OH) 2 from nickel nitrate solutions onto highly oriented pyrolytic graphite at ideal electrodeposition current efficiencies and the deposition mechanism was also characterized.« less
Dielectric Barrier Discharges: Pulsed Breakdown, Electrical Characterization and Chemistry
2013-06-01
DIELECTRIC BARRIER DISCHARGES : PULSED BREAKDOWN, ELECTRICAL CHARACTERIZATION AND CHEMISTRY R. Brandenburg, H. Höft, T. Hoder, A. Pipa, R...for pulsed driven Dielectric Barrier Discharges (DBDs) in particular. Fast electrical, optical and spectroscopic methods enable the study of...2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Dielectric Barrier Discharges : Pulsed Breakdown, Electrical Characterization
Detection of incipient defects in cables by partial discharge signal analysis
NASA Astrophysics Data System (ADS)
Martzloff, F. D.; Simmon, E.; Steiner, J. P.; Vanbrunt, R. J.
1992-07-01
As one of the objectives of a program aimed at assessing test methods for in-situ detection of incipient defects in cables due to aging, a laboratory test system was implemented to demonstrate that the partial discharge analysis method can be successfully applied to low-voltage cables. Previous investigations generally involved cables rated 5 kV or higher, while the objective of the program focused on the lower voltages associated with the safety systems of nuclear power plants. The defect detection system implemented for the project was based on commercially available signal analysis hardware and software packages, customized for the specific purposes of the project. The test specimens included several cables of the type found in nuclear power plants, including artificial defects introduced at various points of the cable. The results indicate that indeed, partial discharge analysis is capable of detecting incipient defects in low-voltage cables. There are, however, some limitations of technical and non-technical nature that need further exploration before this method can be accepted in the industry.
Controls on Filling and Evacuation of Sediment in Waterfall Plunge Pools
NASA Astrophysics Data System (ADS)
Scheingross, J. S.; Lamb, M. P.
2014-12-01
Many waterfalls are characterized by the presence of deep plunge pools that experience periods of sediment fill and evacuation. These cycles of sediment fill are a first order control on the relative magnitude of lateral versus vertical erosion at the base of waterfalls, as vertical incision requires cover-free plunge pools to expose the bedrock floor, while lateral erosion can occur when pools are partially filled and plunge-pool walls are exposed. Currently, there exists no mechanistic model describing sediment transport through waterfall plunge pools, limiting our ability to predict waterfall retreat. To address this knowledge gap, we performed detailed laboratory experiments measuring plunge-pool sediment transport capacity (Qsc_pool) under varying waterfall and plunge-pool geometries, flow hydraulics, and sediment size. Our experimental plunge-pool sediment transport capacity measurements match well with a mechanistic model we developed which combines existing waterfall jet theory with a modified Rouse profile to predict sediment transport capacity as a function of water discharge and suspended sediment concentration at the plunge-pool lip. Comparing the transport capacity of plunge pools to lower gradient portions of rivers (Qsc_river) shows that, for transport limited conditions, plunge pools fill with sediment under modest water discharges when Qsc_river > Qsc_pool, and empty to bedrock under high discharges when Qsc_pool > Qsc_river. These results are consistent with field observations of sand-filled plunge pools with downstream boulder rims, implying filling and excavation of plunge pools over single-storm timescales. Thus, partial filling of waterfall plunge pools may provide a mechanism to promote lateral undercutting and retreat of waterfalls in homogeneous rock in which plunge-pool vertical incision occurs during brief large floods that expose bedrock, whereas lateral erosion may prevail during smaller events.
Janz, David R.; Hollenbeck, Ryan D.; Pollock, Jeremy S.; McPherson, John A.; Rice, Todd W.
2012-01-01
Objective To determine if higher levels of partial pressure of arterial oxygen are associated with in-hospital mortality and poor neurologic status at hospital discharge in patients treated with mild therapeutic hypothermia after sudden cardiac arrest. Design Retrospective analysis of a prospective cohort study Patients A total of 170 consecutive patients treated with therapeutic hypothermia in the cardiovascular care unit of an academic tertiary care hospital. Interventions None. Measurements and Main Results Of 170 patients, 77 (45.2%) survived to hospital discharge. Survivors had a significantly lower maximum partial pressure of arterial oxygen(198 mmHg, IQR 152.5–282) measured in the first 24 hours following cardiac arrest compared to nonsurvivors (254 mmHg, IQR 172–363, p = .022). A multivariable analysis including age, time to return of spontaneous circulation, the presence of shock, bystander CPR, and initial rhythm revealed that higher levels of the partial pressure of arterial oxygen were significantly associated with increased in-hospital mortality (odds ratio 1.439, 95% confidence interval 1.028–2.015, p = 0.034) and poor neurologic status at hospital discharge (odds ratio 1.485, 95% confidence interval 1.032–2.136, p = 0.033). Conclusions Higher levels of the maximum measured partial pressure of arterial oxygen are associated with increased in-hospital mortality and poor neurologic status on hospital discharge in patients treated with mild therapeutic hypothermia after sudden cardiac arrest. PMID:22971589
Gas pressure and electron density at the level of the active zone of hollow cathode arc discharges
NASA Technical Reports Server (NTRS)
Minoo, M. H.
1984-01-01
A model for the longitudinal variations of the partial pressures of electrons, ions, and neutral particles is proposed as a result of an experimental study of pressure variations at the level of the active zone as a function of the various discharge parameters of a hollow cathode arc. The cathode region where the temperature passes through its maximum is called active zone. The proposed model embodies the very important variations which the partial electron and neutral particles pressures undergo at the level of the active zone.
Low-flow frequency analyses for streams in west-central Florida
Hammett, K.M.
1985-01-01
The log-Pearson type III distribution was used for defining low-flow frequency at 116 continuous-record streamflow stations in west-central Florida. Frequency distributions were calculated for 1, 3, 7, 14, 30, 60, 90, 120, and 183 consecutive-day periods for recurrence intervals of 2, 5, 10, and 20 years. Discharge measurements at more than 100 low-flow partial-record stations and miscellaneous discharge-measurement stations were correlated with concurrent daily mean discharge at continuous-record stations. Estimates of the 7-day, 2-year; 7-day, 10-year; 30-day, 2-year; and 30-day, 10-year discharges were made for most of the low-flow partial-record and miscellaneous discharge-measurement stations based on those correlations. Multiple linear-regression analysis was used in an attempt to mathematically relate low-flow frequency data to basin characteristics. The resulting equations showed an apparent bias and were considered unsatisfactory for use in estimating low-flow characteristics. Maps of the 7-day, 10-year and 30-day, 10-year low flows are presented. Techniques that can be used to estimate low-flow characteristics at an ungaged site are also provided. (USGS)
NASA Astrophysics Data System (ADS)
Brandenburg, Ronny
2017-05-01
Dielectric barrier discharges (DBDs) are plasmas generated in configurations with an insulating (dielectric) material between the electrodes which is responsible for a self-pulsing operation. DBDs are a typical example of nonthermal atmospheric or normal pressure gas discharges. Initially used for the generation of ozone, they have opened up many other fields of application. Therefore DBDs are a relevant tool in current plasma technology as well as an object for fundamental studies. Another motivation for further research is the fact that so-called partial discharges in insulated high voltage systems are special types of DBDs. The breakdown processes, the formation of structures, and the role of surface processes are currently under investigation. This review is intended to give an update to the already existing literature on DBDs considering the research and development within the last two decades. The main principles and different modes of discharge generation are summarized. A collection of known as well as special electrode configurations and reactor designs will be presented. This shall demonstrate the different and broad possibilities, but also the similarities and common aspects of devices for different fields of applications explored within the last years. The main part is devoted to the progress on the investigation of different aspects of breakdown and plasma formation with the focus on single filaments or microdischarges. This includes a summary of the current knowledge on the electrical characterization of filamentary DBDs. In particular, the recent new insights on the elementary volume and surface memory mechanisms in these discharges will be discussed. An outlook for the forthcoming challenges on research and development will be given.
Gustafsson, Greta; Broström, Anders; Ulander, Martin; Vrethem, Magnus; Svanborg, Eva
2015-08-01
To determine if melatonin is equally efficient as partial sleep deprivation in inducing sleep without interfering with epileptiform discharges in EEG recordings in children 1-16 years old. We retrospectively analysed 129 EEGs recorded after melatonin intake and 113 EEGs recorded after partial sleep deprivation. Comparisons were made concerning occurrence of epileptiform discharges, the number of children who fell asleep and the technical quality of EEG recordings. Comparison between different age groups was also made. No significant differences were found regarding occurrence of epileptiform discharges (33% after melatonin intake, 36% after sleep deprivation), or proportion of unsuccessful EEGs (8% and 10%, respectively). Melatonin and sleep deprivation were equally efficient in inducing sleep (70% in both groups). Significantly more children aged 1-4 years obtained sleep after melatonin intake in comparison to sleep deprivation (82% vs. 58%, p⩽0.01), and in comparison to older children with melatonin induced sleep (58-67%, p⩽0.05). Sleep deprived children 9-12 years old had higher percentage of epileptiform discharges (62%, p⩽0.05) compared to younger sleep deprived children. Melatonin is equally efficient as partial sleep deprivation to induce sleep and does not affect the occurrence of epileptiform discharges in the EEG recording. Sleep deprivation could still be preferable in older children as melatonin probably has less sleep inducing effect. Melatonin induced sleep have advantages, especially in younger children as they fall asleep easier than after sleep deprivation. The procedure is easier for the parents than keeping a young child awake for half the night. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Birjukova Canelas, Olga; Lage Ferreira, Rui Miguel; Heleno Cardoso, António
2017-04-01
Under steady water and sediment feeding in laboratory conditions, sediment fluxes tend to reach a steady state and bed morphology tends to equilibrium. This laboratory study states two objectives: i) to provide a detailed three-dimensional characterization of the flow field at a movable bed confluence and ii) to contribute to the characterization of the effect of the flow discharge ratio (Qr = Qt/Qm, Qt - tributary flow discharge and Qm - main channel flow discharge) on the flow field. While the junction angle between the main channel and the tributary as well as the sediment discharge ratio were kept constant, two scenarios corresponding to two different flow discharge ratios with dominant main channel flow discharge (Qm > Qt) were analyzed. Prior to the flow velocity measurements, both channels were fed with water and sand mixtures and tests were run until the equilibrium condition was reached, i.e. until the moment where the difference between the total supplied sand discharge and the total outgoing sand discharge was smaller than ± 5%. During the experiments, bed topography was systematically recorded. Then, the flow was stopped, the water was slowly drained and the bed was carefully fixed with a cement and vernix coat and allowed to dry to guarantee that it remained stable from there on, while the clear water (free of sand) discharges were fed again to the fixed bed converging channels. A 3D side looking Acoustic Doppler Velocimeter (ADV), installed on a remotely controlled and precisely positioned (± 0.1 mm) robotic arm, was used to measure the instantaneous velocities at a very dense mesh. Once the velocities measured and recorded, the water surface levels were surveyed. For the case with more dominant tributary flow (Qr = 0.17), as expected, the scour hole formed at the tributary mouth is much deeper and larger and extends towards the outer bank of the post-confluence channel, as well as upstream the junction corner. The avalanche slopes are, consequently, steeper. On the other hand, for the case with a weaker tributary flow (Qr = 0.08), no erosion is observed immediately upstream the junction. Moreover, the bank-attached sediment bar downstream the junction is considerably more developed in longitudinal and vertical directions. In both scenarios, a strong horizontal vortical structure was observed immediately downstream the junction. More detailed analysis of the origin and the characteristics of these and other flow patterns is still under investigation. Acknowledgements This research as partially supported by Portuguese and European funds, within programs COMPETE2020 and PORL-FEDER, through project PTDC/ECM-HID/6387/2014 granted by the National Foundation for Science and Technology (FCT).
Effect of toughened epoxy resin on partial discharge at solid-solid interface
NASA Astrophysics Data System (ADS)
Li, Manping; Wu, Kai; Zhang, Zhao; Cheng, Yonghong
2017-02-01
A series of solid-solid interfaces, consisting of ceramic-epoxy resin interface samples with a tip-plate electrode, were investigated by performing partial discharge tests and real-time electrical tree observations. A toughening agent was added to the epoxy resin at different ratios for comparison. The impact strength, differential scanning calorimetry (DSC) and dielectric properties of the cured compositions and ceramic were tested. The electric field strength at the tip was calculated based on Maxwell’s theory. The test results show that the addition of a toughener can improve the impact strength of epoxy resin but it decreases the partial discharge inception voltage (PDIV) of the interface sample. At the same time, toughening leads to complex branches of the electrical tree. The simulation result suggests that this reduction of the PDIV cannot be explained by a change of permittivity due to the addition of a toughening agent. The microstructural change caused by toughening was considered to be the key factor for lower PDIV and complex electrical tree branches. Supported by China Academy of Engineering Physics (Project 2014B05005).
NASA Astrophysics Data System (ADS)
Danouj, Boujemaa
An important issue affecting the sustainability of power transformers is systematic and progressive deterioration of the insulation system by the action of partial discharge. Ideally, it is appropriate to use on line, non-destructive techniques for detection and diagnosis of failures related to insulation systems, in order to determine whether preventive maintenance action is required. Thus, huge material losses can be saved (spared), while improving reliability and system availability. Based on a new generation of piezoelectric sensors (High Temperature Ultrasonic Transducers HTUTs), recently developed by the Industrial Materials Institute (IMI) in Boucherville (Qc, Canada) and offers very interesting features (broad band frequency response, flexible, miniature, economic, etc..), we propose in this thesis an investigation on the applicability of this technology to the problematic of partial discharges. This work presents an analysis of the metrological performance of these sensors and demonstrated empirically the consistency of their measures. It outlines the results of validation from a comparative study with the measures of a standard detection circuit. In addition, it also presents the potential of these sensors to locate partial discharge source position by acoustic emission.
A single overnight stay is possible for most patients undergoing robotic partial nephrectomy.
Abaza, Ronney; Shah, Ketul
2013-02-01
To evaluate establishment of overnight stay only as sufficient after robotic partial nephrectomy (RPN). Stated benefits of minimally invasive surgery include reduced hospitalization, but published hospital stays after laparoscopic or robotic partial nephrectomy are not significantly less than with open surgery. We developed a clinical pathway targeting discharge on postoperative day (POD) 1 after RPN of any complexity. We reviewed all RPNs by a single surgeon since instituting our clinical pathway, including ambulation and diet the night of surgery, avoidance of intravenous narcotics and drains, and catheter removal on POD 1 before discharge. Targeted discharge was not modified regardless of RPN complexity. A total of 150 consecutive patients underwent 160 RPNs with 35 hilar tumors and 26 with segmental, and 33 with no artery clamping. Three had solitary kidneys, and 8 underwent multiple (range, 2-4) RPNs. Mean patient age was 57 years (range, 22-89 years), and body mass index was 32 kg/m(2) (range, 18-54 kg/m(2)). Mean tumor size was 3.6 cm (range, 1.0-11.0; median, 3.2 cm), and the RENAL (radius, exophytic/endophytic, nearness to collecting system, anterior/posterior, and location) nephrometry score was 8 (range, 4-12; median, 8). Mean warm ischemia time was 12.1 minutes (range, 0-30.0 minutes). Mean preoperative and discharge creatinine were 0.9 mg/dL (range, 0.43-2.79 mg/dL) and 1.13 mg/dL (range, 0.56-2.93 mg/dL). All patients ambulated on POD 0. One patient required one dose of intravenous narcotic. Mean length of stay was 1.1 days, with 145 (97%) discharged on POD 1, of which only 4 (2.7%) were readmitted within 30 days. Discharge on POD 1 is feasible in most RPN patients regardless of complexity. Readmission rate was low, indicating that longer admissions may not prevent complications when patients meeting discharge criteria go home on POD 1. Copyright © 2013 Elsevier Inc. All rights reserved.
Hydrochemical characterization of a mine water geothermal energy resource in NW Spain.
Loredo, C; Ordóñez, A; Garcia-Ordiales, E; Álvarez, R; Roqueñi, N; Cienfuegos, P; Peña, A; Burnside, N M
2017-01-15
Abandoned and flooded mine networks provide underground reservoirs of mine water that can be used as a renewable geothermal energy source. A complete hydrochemical characterization of mine water is required to optimally design the geothermal installation, understand the hydraulic behavior of the water in the reservoir and prevent undesired effects such as pipe clogging via mineral precipitation. Water pumped from the Barredo-Figaredo mining reservoir (Asturias, NW Spain), which is currently exploited for geothermal use, has been studied and compared to water from a separate, nearby mountain mine and a river that receives mine water discharge and partially infiltrates into the mine workings. Although the hydrochemistry was altered during the flooding process, the deep mine waters are currently near neutral, net alkaline, high metal waters of Na-HCO 3 type. Isotopic values suggest that mine waters are closely related to modern meteoric water, and likely correspond to rapid infiltration. Suspended and dissolved solids, and particularly iron content, of mine water results in some scaling and partial clogging of heat exchangers, but water temperature is stable (22°C) and increases with depth, so, considering the available flow (>100Ls -1 ), the Barredo-Figaredo mining reservoir represents a sustainable, long-term resource for geothermal use. Copyright © 2016 Elsevier B.V. All rights reserved.
Fiber Fabry-Perot sensors for detection of partial discharges in power transformers.
Yu, Bing; Kim, Dae Woong; Deng, Jiangdong; Xiao, Hai; Wang, Anbo
2003-06-01
A diaphragm-based interferometric fiberoptic sensor that uses a low-coherence light source was designed and tested for on-line detection of the acoustic waves generated by partial discharges inside high-voltage power transformers. The sensor uses a fused-silica diaphragm and a single-mode optical fiber encapsulated in a fused-silica glass tube to form an extrinsic Fabry-Perot interferometer, which is interrogated by low-coherence light. Test results indicate that these fiber optic acoustic sensors are capable of faithfully detecting acoustic signals propagating inside transformer oil with high sensitivity and wide bandwidth.
Optical fiber sensor of partial discharges in High Voltage DC experiments
NASA Astrophysics Data System (ADS)
Búa-Núñez, I.; Azcárraga-Ramos, C. G.; Posada-Román, J. E.; Garcia-Souto, J. A.
2014-05-01
A setup simulating High Voltage DC (HVDC) transformers barriers was developed to demonstrate the effectiveness of an optical fiber (OF) sensor in detecting partial discharges (PD) under these peculiar conditions. Different PD detection techniques were compared: electrical methods, and acoustic methods. Standard piezoelectric sensors (R15i-AST) and the above mentioned OF sensors were used for acoustic detection. The OF sensor was able to detect PD acoustically with a sensitivity better than the other detection methods. The multichannel instrumentation system was tested in real HVDC conditions with the aim of analyzing the behavior of the insulation (mineral oil/pressboard).
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2010 CFR
2010-01-01
..., metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp..., current, and waveform) for starting and operating. High intensity discharge lamp means an electric... light is produced by radiation from mercury typically operating at a partial vapor pressure in excess of...
Storti, Silvia F; Del Felice, Alessandra; Formaggio, Emanuela; Boscolo Galazzo, Ilaria; Bongiovanni, Luigi G; Cerini, Roberto; Fiaschi, Antonio; Manganotti, Paolo
2015-07-01
The combined use of electroencephalography (EEG) and functional magnetic resonance imaging (EEG-fMRI) in epilepsy allows the noninvasive hemodynamic characterization of epileptic discharge-related neuronal activations. The aim of this study was to investigate pathophysiologic mechanisms underlying epileptic activity by exploring the spatial and temporal distribution of fMRI signal modifications during seizure in a single patient with posttraumatic epilepsy. EEG and fMRI data were acquired during two scanning sessions: a spontaneous critical episode was observed during the first, and interictal events were recorded during the second. The EEG-fMRI data were analyzed using the general linear model (GLM). Blood oxygenation level-dependent (BOLD) localization derived from the preictal and artifact-free postictal phase was concordant with the BOLD localization of the interictal epileptiform discharges identified in the second session, pointing to a left perilesional mesiofrontal area. Of note, BOLD signal modifications were already visible several seconds before seizure onset. In brief, BOLD activations from the preictal, postictal, and interictal epileptiform discharge analysis appear to be concordant with the clinically driven localization hypothesis, whereas a widespread network of activations is detected during the ictal phase in a partial seizure. © EEG and Clinical Neuroscience Society (ECNS) 2014.
Thin film deposition of conducting tin oxide from TMT in a low pressure glow discharge diode reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farber, Y.; Arefi, F.; Amouroux, J.
1993-12-31
This work concerns the study of the deposition mechanisms of tin oxide and its characterization from a mixture of Ar + TMT + O{sub 2} in a RF glow discharge diode reactor at low pressure (0.1-0.3 mbar). The gaseous mixture is introduced in the center of the HV electrode and the glass substrates are placed on the grounded electrode. With the help of an optical fiber fixed in front of a quartz window the discharge was characterized in line. The deposited material is characterized by different surface diagnostic techniques such as XPS, FTIR, SEM/EDX. The sheet conductivity of the thinmore » films were measured by a 4 point-probe measurements. The first step of this work has been to optimize the working parameters (such as the gas composition, the interelectrode gap, the injected power and the treatment time) in order to obtain SnO{sub 2{minus}x}C{sub y} films with reproducible properties. While the second step was devoted to adjust the partial pressure of oxygen in TMT + O{sub 2} + Ar mixture in the aim to decrease the carbon content of the deposit. The carbon-free in oxide films obtained in this way (Sn/O{approx}0.5) present conductivities varying from 10{sup {minus}4} S.cm{sup {minus}1} up to 10{sup 2} S.cm{sup {minus}1} with thicknesses in the range of 500 to 20000 {angstrom}. The conductivity of the films can be improved by either an annealing process in nitrogen gas or by a hydrogen plasma post-treatment. Moreover, in the case of the latter, {beta}Sn crystalline phase has been identified. Finally, the transparent tin oxide films being prepared at relatively low temperature (=100{degrees}C) can be very well realized on polymeric substrates.« less
Cost-effectiveness of the US Geological Survey stream-gaging program in Arkansas
Darling, M.E.; Lamb, T.E.
1984-01-01
This report documents the results of the cost-effectiveness of the stream-gaging program in Arkansas. Data uses and funding sources were identified for the daily-discharge stations. All daily-discharge stations were found to be in one or more data use categories, and none were candidates for alternate methods which would result in discontinuation or conversion to a partial record station. The cost for operation of daily-discharge stations and routing costs to partial record stations, crest gages, pollution control stations as well as seven recording ground-water stations was evaluated in the Kalman-Filtering Cost-Effective Resource allocation (K-CERA) analysis. This operation under current practices requires a budget of $292,150. The average standard error of estimate of streamflow record for the Arkansas District was analyzed at 33 percent.
NASA Astrophysics Data System (ADS)
Shang, Ya-na; Ni, Qing-yan; Ding, Ding; Chen, Na; Wang, Ting-yun
2015-01-01
In this paper, a partial discharge detection system is proposed using an optical fiber Fabry-Perot (FP) interferometric sensor, which is fabricated by photolithography. SU-8 photoresist is employed due to its low Young's modulus and potentially high sensitivity for ultrasound detection. The FP cavity is formed by coating the fiber end face with two layers of SU-8 so that the cavity can be controlled by the thickness of the middle layer of SU-8. Static pressure measurement experiments are done to estimate the sensing performance. The results show that the SU-8 based sensor has a sensitivity of 154.8 nm/kPa, which is much higher than that of silica based sensor under the same condition. Moreover, the sensor is demonstrated successfully to detect ultrasound from electrode discharge.
Groundwater flow in a coastal peatland and its influence on submarine groundwater discharge
NASA Astrophysics Data System (ADS)
Ptak, T.; Ibenthal, M.; Janssen, M.; Massmann, G.; Lenartz, B.
2017-12-01
Coastal peatlands are characterized by intense interactions between land and sea, comprising both a submarine discharge of fresh groundwater and inundations of the peatland with seawater. Nutrients and salts can influence the biogeochemical processes both in the shallow marine sediments and in the peatland. The determination of flow direction and quantity of groundwater flow are therefore elementary. Submarine groundwater discharge (SGD) has been reported from several locations in the Baltic. The objective of this study is to quantify the exchange of fresh and brackish water across the shoreline in a coastal peatland in Northeastern Germany, and to assess the influence of a peat layer extending into the Baltic Sea. Below the peatland, a shallow fine sand aquifer differs in depth and is limited downwards by glacial till. Water level and electrical conductivity (EC) are permanently measured in different depths at eight locations in the peatland. First results indicate a general groundwater flow direction towards the sea. Electrical conductivity measurements suggest different permeabilities within the peat layer, depending on its thickness and degradation. Near the beach, EC fluctuates partially during storm events due to seawater intrusion and reverse discharge afterwards. The groundwater flow will be verified with a 3D model considering varying thicknesses of the aquifer. Permanent water level and electrical conductivity readings, meteorological data and hydraulic conductivity from slug tests and grain size analysis are the base for the calibration of the numerical model.
Water Resources Data, New Jersey, Water Year 2003; Volume 1. Surface-Water Data
Reed, T.J.; White, B.T.; Centinaro, G.L.; Dudek, J.F.; Protz, A.R.; Shvanda, J.C.; Watson, A.F.
2004-01-01
Water-resources data for the 2003 Water Year for New Jersey are presented in three volumes, and consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground water. Volume 1 contains discharge records for 100 gaging stations; tide summaries at 29 tidal gaging stations; and stage and contents at 39 lakes and reservoirs. Also included are stage and discharge for 106 crest-stage partial-record stations, stage-only at 33 tidal crest-stage gages, and discharge for 142 low-flow partial- record stations. Locations of these sites are shown in figures 8-11. Additional discharge measurements were made at 143 miscellaneous sites that are not part of the systematic data-collection program. Discontinued station tables for gaging stations, crest-stage gages, tidal crest-stage and tidal gaging stations show historical coverage. The data in this report represent that part of the National Water Information System (NWIS) data collected by the United States Geological Survey (USGS). Hydrologic conditions are also described for this water year, including streamflow, precipitation, reservoir conditions, and air temperatures.
Water resources data, New Jersey, water year 2005. Volume 1 - surface-water data
White, B.T.; Hoppe, H.L.; Centinaro, G.L.; Dudek, J.F.; Painter, B.S.; Protz, A.R.; Reed, T.J.; Shvanda, J.C.; Watson, A.F.
2006-01-01
Water-resources data for the 2005 water year for New Jersey are presented in three volumes, and consists of records of stage, discharge, and water-quality of streams; stage and contents of lakes and reservoirs; and water levels and water-quality of ground water. Volume 1 contains discharge records for 103 gaging stations; tide summaries at 28 tidal gaging stations; stage and contents at 34 lakes and reservoirs; and diversions from 50 surface-water sources. Also included are stage and discharge for 116 crest-stage partial-record stations, stage-only at 33 tidal crest-stage gages, and discharge for 155 low-flow partial-record stations. Locations of these sites are shown in figures 8-11. Additional discharge measurements were made at 222 miscellaneous sites that are not part of the systematic data-collection program. Discontinued station tables for gaging stations, crest-stage gages, tidal crest-stage and tidal gaging stations show historical coverage. The data in this report represent that part of the National Water Information System (NWIS) data collected by the United States Geological Survey (USGS). Hydrologic conditions are also described for this water year, including stream-flow, precipitation, reservoir conditions, and air temperatures.
Water resources data, New Jersey, water year 2004-volume 1. surface-water data
Centinaro, G.L.; White, B.T.; Hoppe, H.L.; Dudek, J.F.; Protz, A.R.; Reed, T.J.; Shvanda, J.C.; Watson, A.F.
2005-01-01
Water-resources data for the 2004 water year for New Jersey are presented in three volumes, and consists of records of stage, discharge, and water-quality of streams; stage and contents of lakes and reservoirs; and water levels and water-quality of ground water. Volume 1 contains discharge records for 105 gaging stations; tide summaries at 27 tidal gaging stations; stage and contents at 39 lakes and reservoirs; and diversions from 51 surface-water sources. Also included are stage and discharge for 108 crest-stage partial-record stations, stage-only at 34 tidal crest-stage gages, and discharge for 124 low-flow partial-record stations. Locations of these sites are shown in figures 8-11. Additional discharge measurements were made at 131 miscellaneous sites that are not part of the systematic data-collection program. Discontinued station tables for gaging stations, crest-stage gages, tidal crest-stage and tidal gaging stations show historical coverage. The data in this report represent that part of the National Water Information System (NWIS) data collected by the United States Geological Survey (USGS). Hydrologic conditions are also described for this water year, including stream-flow, precipitation, reservoir conditions, and air temperatures.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Gilland, James H.; Haag, Thomas W.; Mackey, Jonathan; Yim, John; Pinero, Luis; Williams, George; Peterson, Peter; Herman, Daniel
2017-01-01
NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-3 (TDU-3) has been the subject of extensive technology maturation in preparation for flight system development. Detailed performance, stability, and plume characterization tests of the thruster were performed at NASA GRC's Vacuum Facility 5 (VF-5). The TDU-3 thruster implements a magnetic topology that is identical to TDU-1. The TDU-3 boron nitride silica composite discharge channel material is different than the TDU-1 heritage boron nitride discharge channel material. Performance and stability characterization of the TDU-3 thruster was performed at discharge voltages between 300V and 600V and at discharge currents between 5A and 21.8A. The thruster performance and stability were assessed for varying magnetic field strength, cathode flow fractions between 5% and 9%, varying harness inductance, and for reverse magnet polarity. Performance characterization test results indicate that the TDU-3 thruster performance is in family with the TDU-1 levels. TDU-3's thrust efficiency of 65% and specific impulse of 2,800sec at 600V and 12.5kW exceed performance levels of SOA Hall thrusters. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations (discharge current peak-to-peak and root mean square magnitudes), discharge current waveform power spectral density analysis, and maps of the current-voltage-magnetic field. Stability characterization test results indicate a stability profile similar to TDU-1. Finally, comparison of the TDU-1 and TDU-3 plume profiles found that there were negligible differences in the plasma plume characteristics between the TDU with heritage boron nitride versus the boron nitride silica composite discharge channel.
NASA Astrophysics Data System (ADS)
Saravanan, M.; Ganesan, M.; Ambalavanan, S.
2014-04-01
In this work, we report an in situ generated carbon from sugar as additive in the Negative Active Mass (NAM) which enhances the charge-discharge characteristics of the lead-acid cells. In situ formed sugar derived carbon (SDC) with leady oxide (LO) provides a conductive network and excellent protection against NAM irreversible lead sulfation. The effect of SDC and carbon black (CB) added negative plates are characterized by X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy (SEM), galvanostatic charge-discharge, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), respectively. The results show that subtle changes in the addition of carbon to NAM led to subsequent changes on the performance during partial-state-of-charge (PSoC) operations in lead-acid cells. Furthermore, SDC added cells exhibit remarkable improvement in the rate capability, active material utilization, cycle performance and charge acceptance compared to that of the conventional CB added cells. The impact of SDC with LO at various synthesis conditions on the electrochemical performance of the negative plate is studied systematically.
Methane chemistry involved in a low-pressure electron cyclotron wave resonant plasma discharge
NASA Astrophysics Data System (ADS)
Morrison, N. A.; William, C.; Milne, W. I.
2003-12-01
Radio frequency (rf) generated methane plasmas are commonly employed in the deposition of hydrogenated amorphous carbon (a-C:H) thin films. However, very little is known about the rf discharge chemistry and how it relates to the deposition process. Consequently, we have characterized a low-pressure methane plasma and compared the results with those obtained theoretically by considering the steady-state kinetics of the chemical processes present in a low-pressure plasma reactor, in order to elucidate the dominant reaction channels responsible for the generation of the active precursors required for film growth. Mass spectrometry measurements of the gas phase indicated little variation in the plasma chemistry with increasing electron temperature. This was later attributed to the partial saturation of the electron-impact dissociation and ionization rate constants at electron temperatures in excess of ˜4 eV. The ion densities in the plasma were also found to be strongly dependent upon the parent neutral concentration in the gas phase, indicating that direct electron-impact reactions exerted greater influence on the plasma chemistry than secondary ion-neutral reactions.
Characterization of a Plasmoid in the Afterglow of a Supersonic Flowing Microwave Discharge
NASA Technical Reports Server (NTRS)
Drake, D. J.; Miller, S.; Nikolic, M.; Popovic, S.; Vuskovic, L.
2009-01-01
We performed a detailed characterization a plasmoid in the afterglow region of an Ar supersonic microwave cavity discharge. The supersonic flow was generated using a convergent-divergent nozzle upstream of the discharge region. A cylindrical cavity was used to sustain a discharge in the pressure range of 100-600 Pa. Optical emission spectroscopy was used to observe populations of excited and ionic species in the plasmoid region. Plasmoid formation in the supersonic flowing afterglow located downstream from the primary microwave cavity discharge was characterized by measuring the radial and axial distributions of Argon excited states and Argon ions. More experiments are being carried out on the plasmoid to understand the discharge parameters within the region, i.e. rotational temperature, vibrational temperature, electron density, and how the electrodynamic and aerodynamic effects combine to form this plasmoid.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banerjee, Srutarshi; Rajan, Rehim N.; Singh, Sandeep K.
2014-07-01
DC Accelerators undergoes different types of discharges during its operation. A model depicting the discharges has been simulated to study the different transient conditions. The paper presents a Physics based approach of developing a compact circuit model of the DC Accelerator using Partial Element Equivalent Circuit (PEEC) technique. The equivalent RLC model aids in analyzing the transient behavior of the system and predicting anomalies in the system. The electrical discharges and its properties prevailing in the accelerator can be evaluated by this equivalent model. A parallel coupled voltage multiplier structure is simulated in small scale using few stages of coronamore » guards and the theoretical and practical results are compared. The PEEC technique leads to a simple model for studying the fault conditions in accelerator systems. Compared to the Finite Element Techniques, this technique gives the circuital representation. The lumped components of the PEEC are used to obtain the input impedance and the result is also compared to that of the FEM technique for a frequency range of (0-200) MHz. (author)« less
Characteristics of long-gap AC streamer discharges under low pressure conditions
NASA Astrophysics Data System (ADS)
Yang, Yaqi; Li, Weiguo; Xia, Yu; Yuan, Chuangye
2017-10-01
The generation and propagation of a streamer is a significant physical process of air gap discharge. Research on the mechanism of streamers under low-pressure conditions is helpful for understanding the process of long-gap discharge in a high-altitude area. This paper describes laboratory investigations of streamer discharge under alternating current (AC) voltage in a low pressure test platform for a 60 cm rod-plane gap at 30 kPa, and analyzes the characteristics of streamer generation and propagation. The results show that the partial streamer and breakdown streamer all occur in the positive half-cycle of AC voltage near the peak voltage at 30 kPa. The partial streamer could cause the distortion of current and voltage waveform, and it appears as the branching characteristic at the initial stage. With the extension of the streamer, the branching and tortuosity phenomena become gradually obvious, but the branching is suppressed when the streamer crosses the gap. The low-pressure condition has little influence on the tortuosity length and the tortuosity number of the streamer, but affect the diameter of streamer obviously.
2014-05-01
vulnerable to failure is air. This could be a discharge through an air medium or along an air/surface interface. Achieving robustness in dc power...sputtering” arcs) are discharges that are most commonly located in series with the intended load; the electrical impedance of the load limits the...particularly those used at voltages > 1000 V, is detection and measurement of partial- discharge (PD) activity. The presence of PD in a component typically
Wong, Shi-Bing; Cheng, Sin-Jhong; Hung, Wei-Chen; Lee, Wang-Tso; Min, Ming-Yuan
2015-01-01
Peroxisomal proliferator-activated receptor gamma (PPARγ) is a nuclear hormone receptor whose agonist, rosiglitazone has a neuroprotective effect to hippocampal neurons in pilocarpine-induced seizures. Hippocampal slice preparations treated in Mg2+ free medium can induce ictal and interictal-like epileptiform discharges, which is regarded as an in vitro model of N-methyl-D-aspartate (NMDA) receptor-mediated temporal lobe epilepsy (TLE). We applied rosiglitazone in hippocampal slices treated in Mg2+ free medium. The effects of rosiglitazone on hippocampal CA1-Schaffer collateral synaptic transmission were tested. We also examined the neuroprotective effect of rosiglitazone toward NMDA excitotoxicity on cultured hippocampal slices. Application of 10 μM rosiglitazone significantly suppressed amplitude and frequency of epileptiform discharges in CA1 neurons. Pretreatment with the PPARγ antagonist GW9662 did not block the effect of rosiglitazone on suppressing discharge frequency, but reverse the effect on suppressing discharge amplitude. Application of rosiglitazone suppressed synaptic transmission in the CA1-Schaffer collateral pathway. By miniature excitatory-potential synaptic current (mEPSC) analysis, rosiglitazone significantly suppressed presynaptic neurotransmitter release. This phenomenon can be reversed by pretreating PPARγ antagonist GW9662. Also, rosiglitazone protected cultured hippocampal slices from NMDA-induced excitotoxicity. The protective effect of 10 μM rosiglitazone was partially antagonized by concomitant high dose GW9662 treatment, indicating that this effect is partially mediated by PPARγ receptors. In conclusion, rosiglitazone suppressed NMDA receptor-mediated epileptiform discharges by inhibition of presynaptic neurotransmitter release. Rosiglitazone protected hippocampal slice from NMDA excitotoxicity partially by PPARγ activation. We suggest that rosiglitazone could be a potential agent to treat patients with TLE.
Pulsed electrothermal thruster
NASA Technical Reports Server (NTRS)
Burton, Rodney L. (Inventor); Goldstein, Yeshayahu S. A. (Inventor); Tidman, Derek A. (Inventor); Winsor, Niels K. (Inventor)
1989-01-01
A plasma electrothermal thruster includes a capillary passage in which a plasma discharge is formed and directed out of an open end of the passage into a supersonic nozzle. Liquid supplied to the capillary passage becomes partially atomized to cool a confining surface of the passage. The plasma discharge is formed as the atomized liquid flows out of the open end into a supersonic equilibrium nozzle. The discharge can have a duration greater than the two way travel time of acoustic energy in the capillary to cause the plasma to flow continuously through the nozzle during the time of the discharge pulse.
NASA Astrophysics Data System (ADS)
Naddaf, M.; Abdallah, B.; Ahmad, M.; A-Kharroub, M.
2016-08-01
The influence of N2 partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N2 partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N2 partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N2 partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N2 partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N2 partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N2 partial pressure.
Water resources data for New Mexico, water year 1975
,
1976-01-01
Water resources data for the 1975 water year for New Mexico consist of records of discharge and water quality of streams; stage, contents and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. This report contains discharge records for 201 gaging stations; stage and contents far 23 lakes and reservoirs; water quality for 62 gaging stations, 77 partial-record flow stations, 1 reservoir, 47 springs and 197 wells; and water levels for 93 observation wells. Also included are 162 crest-stage partial-record stations and 2 low-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic da,ta collection program, and are pu,blis"Q,ed as miscellaneous measurements. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in New Mexico.
Discharge Characterization of 40 cm-Microwave ECR Ion Source and Neutralizer
NASA Technical Reports Server (NTRS)
Foster, John E.; Patterson, Michael J.; Britton, Melissa
2003-01-01
Discharge characteristics of a 40 cm, 2.45 GHz Electron Cyclotron Resonance (ECR) ion thruster discharge chamber and neutralizer were acquired. Thruster bulk discharge plasma characteristics were assessed using a single Langmuir probe. Total extractable ion current was measured as a function of input microwave power and flow rate. Additionally, radial ion current density profiles at the thruster.s exit plane were characterized using five equally spaced Faraday probes. Distinct low and high density operating modes were observed as discharge input power was varied from 0 to 200 W. In the high mode, extractable ion currents as high as 0.82 A were measured. Neutralizer emission current was characterized as a function of flow rate and microwave power. Neutralizer extraction currents as high as 0.6 A were measured.
Weight loss and jaundice in healthy term newborns in partial and full rooming-in.
Zuppa, Antonio Alberto; Sindico, Paola; Antichi, Eleonora; Carducci, Chiara; Alighieri, Giovanni; Cardiello, Valentina; Cota, Francesco; Romagnoli, Costantino
2009-09-01
An inadequate start of breastfeeding has been associated with reduced caloric intake, excessive weight loss and high serum bilirubin levels in the first days of life. The rooming-in has been proposed as an optimal model for the promotion of breastfeeding. The aim of this study was to compare two different feeding models (partial and full rooming-in) to evaluate differences as regard to weight loss, hyperbilirubinemia and prevalence of exclusive breastfeeding at discharge. A total of 903 healthy term newborns have been evaluated; all the newborns were adequate for gestational age, with birth weight > or = 2800 g and gestational age > or = 37 weeks. The maximum weight loss (mean +/- SD), expressed as percent of birth weight, was not different in the two models (partial vs. full rooming-in 5.8% +/- 1.7%vs. 6% +/- 1.7%). A weight loss > or = 10% occurred in less than 1% in both groups. There were no statistical differences neither as mean of total serum bilirubin (partial vs. full rooming-in 10.5 +/- 3.3 vs. 10.1 +/- 2.9 mg/dl), nor as prevalence of hyperbilirubinemia (total serum bilirubin > or = 12 mg/dl). The prevalence of severe hyperbilirubinemia (total serum bilirubin > or = 18 mg/dl) and the use of phototherapy were not statistically different. Maximum weight loss was similar in the two models, even dividing by total serum bilirubin levels. At the discharge, exclusively breastfed newborns were 81% in full rooming-in and 42.9% in partial rooming-in. In conclusion, our results allow considering our assistance models similar as regards to severe hyperbilirubinemia and pathological weight loss in term healthy newborns even if full rooming-in is associated with higher prevalence of exclusive breastfeeding at the discharge.
Kinetic models for the VASIMR thruster helicon plasma source
NASA Astrophysics Data System (ADS)
Batishchev, Oleg; Molvig, Kim
2001-10-01
Helicon gas discharge [1] is widely used by industry because of its remarkable efficiency [2]. High energy and fuel efficiencies make it very attractive for space electrical propulsion applications. For example, helicon plasma source is used in the high specific impulse VASIMR [3] plasma thruster, including experimental prototypes VX-3 and upgraded VX-10 [4] configurations, which operate with hydrogen (deuterium) and helium plasmas. We have developed a set of models for the VASIMR helicon discharge. Firstly, we use zero-dimensional energy and mass balance equations to characterize partially ionized gas condition/composition. Next, we couple it to one-dimensional hybrid model [6] for gas flow in the quartz tube of the helicon. We compare hybrid model results to a purely kinetic simulation of propellant flow in gas feed + helicon source subsystem. Some of the experimental data [3-4] are explained. Lastly, we discuss full-scale kinetic modeling of coupled gas and plasmas [5-6] in the helicon discharge. [1] M.A.Lieberman, A.J.Lihtenberg, 'Principles of ..', Wiley, 1994; [2] F.F.Chen, Plas. Phys. Contr. Fus. 33, 339, 1991; [3] F.Chang-Diaz et al, Bull. APS 45 (7) 129, 2000; [4] J.Squire et al., Bull. APS 45 (7) 130, 2000; [5] O.Batishchev et al, J. Plasma Phys. 61, part II, 347, 1999; [6] O.Batishchev, K.Molvig, AIAA technical paper 2000-3754, -14p, 2001.
Influence of DC arc current on the formation of cobalt-based nanostructures
NASA Astrophysics Data System (ADS)
Orpe, P. B.; Balasubramanian, C.; Mukherjee, S.
2017-08-01
The synthesis of cobalt-based magnetic nanostructures using DC arc discharge technique with varying arc current is reported here. The structural, morphological, compositional and magnetic properties of these nanostructures were studied as a function of applied arc current. Various techniques like X-ray diffraction, transmission electron microscopy, EDAX and vibrating sample magnetometry were used to carry out this study and the results are reported here. The results clearly indicate that for a given oxygen partial pressure, an arc current of 100 A favours the formation of unreacted cobalt atomic species. Also change in arc current leads to variation in phase, diversity in morphology etc. Other property changes such as thermal changes, mechanical changes etc. are not addressed here. The magnetic characterization further indicates that the anisotropy in shape plays a crucial role in deciding the magnetic properties of the nanostructured materials. We have quantified an interesting result in our experiment, that is, for a given partial pressure, 100 A arc current results in unique variation in structural and magnetic properties as compared to other arc currents.
Anderson, S.; Markham, K.L.; Trujillo, L.F.; Shelton, W.F.; Grillo, D.A.
1987-01-01
Water resources data for the 1985 water year for California consists of records of stage, discharge, and water quality of streams; and stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 2 contains discharge records for 133 gaging stations; stage and contents for 9 lakes and reservoirs; and water quality for 34 stations. Also included are 3 low-flow partial-record stations and 1 water-quality partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Li, Jisheng; Xin, Xiaohu; Luo, Yongfen; Ji, Haiying; Li, Yanming; Deng, Junbo
2013-11-01
A conformal combined sensor is designed and it is used in Partial Discharge (PD) location experiments in transformer oil. The sensor includes a cross-shaped ultrasonic phased array of 13 elements and an ultra-high-frequency (UHF) electromagnetic rectangle array of 2 × 2 elements. Virtual expansion with high order cumulants, the ultrasonic array can achieve the effect of array with 61 elements. This greatly improves the aperture and direction sharpness of original array and reduces the cost of follow-up hardware. With the cross-shaped ultrasonic array, the results of PD location experiments are precise and the maximum error of the direction of arrival (DOA) is less than 5°.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayes, P.D.; Agajanian, J.A.; Rockwell, G.L.
1995-03-01
Water resources data for the 1994 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 143 streamflow-gaging stations, 15 crest-stage partial-record streamflow stations; (2) stage and contents records for 20 lakes and reservoirs; (3) water quality records for 19 streamflow-gaging stations and 2 partial-record stations; and (4) precipitation records for 8 stations.
Archer, Roger J.
1978-01-01
Minimum average 7-day, 10-year flow at 67 gaging stations and 173 partial-record stations in the Hudson River basin are given in tabular form. Variation of the 7-day, 10-year low flow from point to point in selected reaches, and the corresponding times of travel, are shown graphically for Wawayanda Creek, Wallkill River, Woodbury-Moodna Creek, and the Fishkill Creek basins. The 7-day, 10-year low flow for the Saw Kill basin, and estimates of the 7-day, 10-year low flow of the Roeliff Jansen Kill at Ancram and of Birch Creek at Pine Hill, are given. Summaries of discharge from Rondout and Ashokan Reservoirs, in Ulster County, are also included. Minimum average 7-day, 10-year flow for gaging stations with 10 years or more of record were determined by log-Pearson Type III computation; those for partial-record stations were developed by correlation of discharge measurements made at the partial-record stations with discharge data from appropriate long-term gaging stations. The variation in low flows from point to point within the selected subbasins were estimated from available data and regional regression formula. Time of travel at these flows in the four subbasins was estimated from available data and Boning's equations.
Classification of Partial Discharge Measured under Different Levels of Noise Contamination.
Jee Keen Raymond, Wong; Illias, Hazlee Azil; Abu Bakar, Ab Halim
2017-01-01
Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD) and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE) cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA) features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN), Adaptive Neuro-Fuzzy Inference System (ANFIS) and Support Vector Machine (SVM). It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination.
Discharging a DC bus capacitor of an electrical converter system
Kajouke, Lateef A; Perisic, Milun; Ransom, Ray M
2014-10-14
A system and method of discharging a bus capacitor of a bidirectional matrix converter of a vehicle are presented here. The method begins by electrically shorting the AC interface of the converter after an AC energy source is disconnected from the AC interface. The method continues by arranging a plurality of switching elements of a second energy conversion module into a discharge configuration to establish an electrical current path from a first terminal of an isolation module, through an inductive element, and to a second terminal of the isolation module. The method also modulates a plurality of switching elements of a first energy conversion module, while maintaining the discharge configuration of the second energy conversion module, to at least partially discharge a DC bus capacitor.
Impacts of blending on dilution of negatively buoyant brine discharge in a shallow tidal sea.
Kämpf, Jochen
2009-07-01
A fine-resolution three-dimensional hydrodynamic model is applied to study the dilution of desalination brine discharged into a tidal sea. Based on given inflow rate and salinity excess of discharge brine, this study explores variations in mid-field dilutions when other low-salinity wastewater is added to the discharge. Findings reveal that this blending leads to a decrease in dilution in the mixing zone and therefore to higher levels of pollutants in this zone, while, on the other hand, the mixing zone occupies a smaller area. The reason is that the discharge of brine creates a density-driven flow that operates to partially remove effluent from the discharge location. This removal is less efficient for the decrease in density excess of the discharge. Hence, in an ambient sea of moderate mixing, blending can be expected to increase the risk of marine pollution in the mixing zone.
26 CFR 1.662(a)-4 - Amounts used in discharge of a legal obligation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the terms of a will or trust instrument, is used in full or partial discharge or satisfaction of a... support his minor child if under local law property or income from property owned by the child cannot be... law a mother may use the resources of a child for the child's support in lieu of supporting him...
Morison, Gordon; Boreham, Philip
2018-01-01
Electromagnetic Interference (EMI) is a technique for capturing Partial Discharge (PD) signals in High-Voltage (HV) power plant apparatus. EMI signals can be non-stationary which makes their analysis difficult, particularly for pattern recognition applications. This paper elaborates upon a previously developed software condition-monitoring model for improved EMI events classification based on time-frequency signal decomposition and entropy features. The idea of the proposed method is to map multiple discharge source signals captured by EMI and labelled by experts, including PD, from the time domain to a feature space, which aids in the interpretation of subsequent fault information. Here, instead of using only one permutation entropy measure, a more robust measure, called Dispersion Entropy (DE), is added to the feature vector. Multi-Class Support Vector Machine (MCSVM) methods are utilized for classification of the different discharge sources. Results show an improved classification accuracy compared to previously proposed methods. This yields to a successful development of an expert’s knowledge-based intelligent system. Since this method is demonstrated to be successful with real field data, it brings the benefit of possible real-world application for EMI condition monitoring. PMID:29385030
Non-Contact Thermal Characterization of NASA's HERMeS Hall Thruster
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Kamhawi, Hani; Myers, James L.; Yim, John T.; Neff, Gregory
2015-01-01
The thermal characterization test of NASA's 12.5-kW Hall Effect Rocket with Magnetic Shielding has been completed. This thruster was developed to support a number of potential Solar Electric Propulsion Technology Demonstration Mission concepts, including the Asteroid Redirect Robotic Mission concept. As a part of the preparation for this characterization test, an infrared-based, non-contact thermal imaging system was developed to measure the temperature of various thruster surfaces that are exposed to high voltage or plasma. An in-situ calibration array was incorporated into the setup to improve the accuracy of the temperature measurement. The key design parameters for the calibration array were determined in a separate pilot test. The raw data from the characterization test was analyzed though further work is needed to obtain accurate anode temperatures. Examination of the front pole and discharge channel temperatures showed that the thruster temperature was driven more by discharge voltage than by discharge power. Operation at lower discharge voltages also yielded more uniform temperature distributions than at higher discharge voltages. When operating at high discharge voltage, increasing the magnetic field strength appeared to have made the thermal loading azimuthally more uniform.
Altman, Irwin M; Swick, Shannon; Malec, James F
2013-09-01
To (1) assess the effectiveness of home- and community-based rehabilitation (HCBR) in a large cohort of individuals with disabilities secondary to cerebrovascular accident (CVA); and (2) evaluate the responsiveness to treatment of the Mayo-Portland Adaptability Inventory (MPAI-4) to changes resulting from HCBR in this patient group. Retrospective analysis of program evaluation data for treatment completers and noncompleters. HCBR conducted in 7 geographically distinct U.S. cities. Individuals with CVA (n=738) who completed the prescribed course of rehabilitation (completed course of treatment [CCT]) compared with 150 individuals who were precipitously discharged (PD) before program completion. HCBR delivered by certified professional staff on an individualized basis. Mayo-Portland Adaptability Inventory (MPAI-4) completed by professional consensus on admission and at discharge. With the use of analysis of covariance, MPAI-4 total scores at discharge for CCT participants were compared with those of PD participants, with admission MPAI-4, age, length of stay, and time since event as covariates. CCT participants showed greater improvement than PD participants (F=99.48, P<.001) with a moderate effect size (partial η(2)=.10). Group differences and effect sizes were similar for the 3 index scores: Ability (F=75.96, P<.001; partial η(2)=.08), Adjustment (F=99.67, P<.001; partial η(2)=.10), and Participation (F=69.15, P<.001; partial η(2)=.07). Individuals in the CCT group who received the entire planned course of HCBR showed greater improvement on all MPAI-4 indexes than those in the PD group who were discharged before completing the prescribed program. This dose-response relationship provides evidence of a causal relationship between treatment and outcome. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Improving detection sensitivity for partial discharge monitoring of high voltage equipment
NASA Astrophysics Data System (ADS)
Hao, L.; Lewin, P. L.; Swingler, S. G.
2008-05-01
Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by the authors has shown that an electro-optic system can be used for PD measurement of oil-filled power transformers. A PD signal generated within an oil-filled power transformer may reach a winding and then travel along the winding to the bushing core bar. The bushing, acting like a capacitor, can transfer the high frequency components of the partial discharge signal to its earthed tap point. Therefore, an effective PD current measurement can be implemented at the bushing tap by using a radio frequency current transducer around the bushing-tap earth connection. In addition, the use of an optical transmission technique not only improves the electrical noise immunity and provides the possibility of remote measurement but also realizes electrical isolation and enhances safety for operators. However, the bushing core bar can act as an aerial and in addition noise induced by the electro-optic modulation system may influence overall measurement sensitivity. This paper reports on a machine learning technique, namely the use of a support vector machine (SVM), to improve the detection sensitivity of the system. Comparison between the signal extraction performances of a passive hardware filter and the SVM technique has been assessed. The results obtained from the laboratory-based experiment have been analysed and indicate that the SVM approach provides better performance than the passive hardware filter and it can reliably detect discharge signals with apparent charge greater than 30 pC.
A simple kinetic model of a Ne-H2 Penning-plasma laser
NASA Astrophysics Data System (ADS)
Petrov, G. M.; Stefanova, M. S.; Pramatarov, P. M.
1995-09-01
A simple kinetic model of the Ne-H2 Penning-Plasma Laser (PPL) (NeI 585.3 nm) is proposed. The negative glow of a hollow cathode discharge at intermediate pressures is considered as the active medium. The balance equations for the upper and lower laser levels, electrons, ions and electron energy are solved. The dependences of the laser gain on the discharge conditions (Ne and H2 partial pressures, discharge current) are calculated and measured. The calculated values are in a good agreement with the experimental data.
Bryson, Amanda E; Scipioni, Anna M; Essayli, Jamal H; Mahoney, Johnna R; Ornstein, Rollyn M
2018-05-01
To assess long-term outcomes of patients with avoidant/restrictive food intake disorder (ARFID) treated in a partial hospitalization program (PHP) for eating disorders (ED). A cross-sectional study comparing patients with ARFID to those with anorexia nervosa (AN) who had been discharged from a PHP for at least 12 months was performed. Percent median body mass index (%MBMI), scores on the Children's Eating Attitudes Test (ChEAT), and treatment utilization were assessed, with intake and discharge data collected via retrospective chart review. Of the 137 eligible patients, 62 (45.3%) consented to follow-up data collection. Patients with ARFID and AN exhibited similar increases in %MBMI from intake to discharge and reported low scores on the ChEAT by discharge. Patients with ARFID and AN maintained good weight outcomes and low ChEAT scores at follow-up. Most participants were still receiving outpatient treatment from a variety of providers, although fewer with ARFID than AN continued to receive services from our multidisciplinary ED clinic. Patients with ARFID and AN exhibit similar improvements in %MBMI when treated in the same PHP and appear to maintain treatment gains at long-term follow-up. Additionally, most patients continue to utilize outpatient services after being discharged from a PHP. © 2018 Wiley Periodicals, Inc.
Lateralized hyperkinetic motor behavior.
Krishnaiah, Balaji; Acharya, Jayant; Ahmed, Aiesha
2018-01-01
Seizures are followed by a post-ictal period, which is characterized by usual slowing of brain activity. This case report describes a 68-year old woman who presented with right-sided rhythmic, non-voluntary, semi-purposeful motor behavior that started 2 days after an episode of generalized seizure. Her initial electroencephalogram (EEG) showed beta activity with no evidence of epileptiform discharges. Computed tomography scan showed hypodensity in the left parieto-occipital region. Magnetic resonance imaging (MRI) showed restricted diffusion/fluid-attenuated inversion recovery hyperintensities in the left precentral and post-central gyrus. Unilateral compulsive motor behavior during the post-ictal state should be considered, and not confused with partial status epilepticus to avoid unnecessary treatment. Abnormal magnetic resonance imaging (MRI) findings, which are reversible, can help with the diagnostic and therapeutic approach.
NASA Astrophysics Data System (ADS)
Yang, Hengzhao; Zhang, Ying
2011-10-01
A new approach is presented to characterize the variable leakage resistance, a parameter in the variable leakage resistance model we developed to model supercapacitors used in environmentally powered wireless sensor network applications. Based on an analysis of the supercapacitor terminal behavior during the self-discharge, the variable leakage resistance is modeled as a function of the supercapacitor terminal voltage instead of the self-discharge time, which is more practical for an environmentally powered wireless sensor node. The new characterization approach is implemented and validated using MATLAB Simulink with a 10 F supercapacitor as an example. In addition, effects of initial voltages and temperatures on the supercapacitor self-discharge rate and the variable leakage resistance value are explored.
Webster, M.D.; Rockwell, G.L.; Friebel, M.F.; Brockner, S.J.
2005-01-01
Water-resources data for the 2004 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 4 contains discharge records for 188 gaging stations, stage and contents for 62 lakes and reservoirs, gage-height records for 1 station, water quality for 20 streamflow-gaging stations and 1 partial-record stations. Also included are 4 miscellaneous partial-record sites. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Freeman, L.A.; Smithson, J.R.; Webster, M.D.; Pope, G.L.; Friebel, M.F.
2003-01-01
Water-resources data for the 2002 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 2 contains discharge records for 133 gaging stations, stage and contents for 8 lakes and reservoirs, gage-height records for 6 stations, water quality for 43 streamflow-gaging stations and 5 partial-record stations. Also included are data for 1 low-flow partial-record station, and 5 miscellaneous-measurement stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Bowers, J.C.; McConaughy, C.E.; Polinoski, K.G.; Smith, G.B.
1988-01-01
Water resources data for the 1986 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 144 gaging stations; stage and contents for 15 lakes and reservoirs; watet quality for 21 streams. Also included are crest-stage partial-record stations, 3 miscellaneous measurement sites, and 5 water-quality partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Bowers, J.C.; McConaughy, C.E.; Polinoski, K.G.; Smith, G.B.
1987-01-01
Water resources data for the 1985 water year for California consists of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 150 gaging stations; stage and contents for 17 lakes and reservoirs; water quality for 23 streams. Also included are 10 crest-stage partial-record stations, three miscellaneous measurement sites, and one waterquality partial-record station. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Type curves for selected problems of flow to wells in confined aquifers
Reed, J.E.
1980-01-01
This report presents type curves and related material for 11 conditions of flow to wells m confined aquifers. These solutions, compiled from hydrologic literature, span an interval of time from Theis (1935) to Papadopulos, Bredehoeft, and Cooper (1973). Solutions are presented for constant discharge, constant drawdown, and variable discharge for pumping wells that fully penetrate leaky and nonleaky aquifers. Solutions for wells that partially penetrate leaky and nonleaky aquifers are included. Also, solutions are included for the effect of finite well radius and the sudden injection of a volume of water for nonleaky aquifers. Each problem includes the partial differential equation, boundary and initial conditions, and solutions. Programs in FORTRAN for calculating additional function values are included for most of the solutions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffman, E.B.; Bowers, J.C.; Mullen, J.R.
1993-09-01
Water resources data for the 1992 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 161 streamflow-gaging stations, 15 crest-stage partial-record streamflow stations, and 5 miscellaneous measurement stations; (2) stage and contents records for 26 lakes and reservoirs; (3) water-quality records for 23 streamflow-gaging stations and 3 partial-record stations; and (4) precipitation records for 11 stations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mullen, J.R.; Hayes, P.D.; Agajanian, J.A.
1994-06-01
Water resources data for the 1993 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 156 streamflow-gaging stations, 12 crest-stage partial-record streamflow stations, and 5 miscellaneous measurement stations; (2) stage and contents records for 26 lakes and reservoirs; (3) water-quality records for 17 streamflow-gaging stations and 6 partial-record stations; and (4) precipitation records for 10 stations.
Characterization of electrical discharges on Teflon dielectrics used as spacecraft thermal control
NASA Technical Reports Server (NTRS)
Yadlowsky, E. J.; Hazelton, R. C.; Churchill, R. J.
1979-01-01
The dual effects of system degradation and reduced life of synchronous-orbit satellites as a result of differential spacecraft charging underscore the need for a clearer understanding of the prevailing electrical discharge phenomena. In a laboratory simulation, the electrical discharge current, surface voltage, emitted particle fluxes, and photo-emission associated with discharge events on electron beam irradiated silver-backed Teflon samples were measured. Sample surface damage was examined with optical and electron beam microscopes. The results are suggestive of a model in which the entire sample surface is discharged by lateral sub-surface currents flowing from a charge deposition layer through a localized discharge channel to the back surface of the sample. The associated return current pulse appears to have a duration which may be a signature by which different discharge processes may be characterized.
Successful Outcome of Twin Gestation with Partial Mole and Co-Existing Live Fetus: A Case Report.
Rathod, Setu; Rani, Reddi; John, Lopamudra B; Samal, Sunil Kumar
2015-08-01
Sad fetus syndrome comprising of a live twin gestation with a hydatidiform mole is a rare entity. The condition is even rarer when the co-existing live fetus is associated with a partial mole than a complete mole. We report the case of a 24-year-old G2P1L1 at 28 weeks gestation who presented to our casualty in the second stage of labour. She had a previous ultrasound scan at 13 weeks which showed a live fetus with a focal area of multicystic placenta. She delivered an alive preterm male fetus weighing 1.32 kg vaginally. Following expulsion of normal placenta of the live fetus, partial mole was expelled. The fetus was admitted to neonatal ICU and discharged after two weeks. Soon after delivery, β-hCG (human chorionic gonadotropin) was 1,21,993 mIU/ml which decreased to 30mIU/ml within two weeks. The patient was discharged with advice of regular follow up of β-hCG reports.
Attainable high capacity in Li-excess Li-Ni-Ru-O rock-salt cathode for lithium ion battery
NASA Astrophysics Data System (ADS)
Wang, Xingbo; Huang, Weifeng; Tao, Shi; Xie, Hui; Wu, Chuanqiang; Yu, Zhen; Su, Xiaozhi; Qi, Jiaxin; Rehman, Zia ur; Song, Li; Zhang, Guobin; Chu, Wangsheng; Wei, Shiqiang
2017-08-01
Peroxide structure O2n- has proven to appear after electrochemical process in many lithium-excess precious metal oxides, representing extra reversible capacity. We hereby report construction of a Li-excess rock-salt oxide Li1+xNi1/2-3x/2Ru1/2+x/2O2 electrode, with cost effective and eco-friendly 3d transition metal Ni partially substituting precious 4d transition metal Ru. It can be seen that O2n- is formed in pristine Li1.23Ni0.155Ru0.615O2, and stably exists in subsequent cycles, enabling discharge capacities to 295.3 and 198 mAh g-1 at the 1st/50th cycle, respectively. Combing ex-situ X-ray absorption near edge spectroscopy, X-ray photoelectron spectroscopy, X-ray diffraction, high resolution transmission electron microscopy and electrochemical characterization, we demonstrate that the excellent electrochemical performance comes from both percolation network with disordered structure and cation/anion redox couples occurring in charge-discharge process. Li-excess and substitution of common element have been demonstrated to be a breakthrough for designing novel high performance commercial cathodes in rechargeable lithium ion battery field.
NASA Astrophysics Data System (ADS)
Zheng, B. C.; Wu, Z. L.; Wu, B.; Li, Y. G.; Lei, M. K.
2017-05-01
A spatially averaged, time-dependent global plasma model has been developed to describe the reactive deposition of a TiAlSiN thin film by modulated pulsed power magnetron sputtering (MPPMS) discharges in Ar/N2 mixture gas, based on the particle balance and the energy balance in the ionization region, and considering the formation and erosion of the compound at the target surface. The modeling results show that, with increasing the N2 partial pressure from 0% to 40% at a constant working pressure of 0.3 Pa, the electron temperature during the strongly ionized period increases from 4 to 7 eV and the effective power transfer coefficient, which represents the power fraction that effectively heats the electrons and maintains the discharge, increases from about 4% to 7%; with increasing the working pressure from 0.1 to 0.7 Pa at a constant N2 partial pressure of 25%, the electron temperature decreases from 10 to 4 eV and the effective power transfer coefficient decreases from 8% to 5%. Using the modeled plasma parameters to evaluate the kinetic energy of arriving ions, the ion-to-neutral flux ratio of deposited species, and the substrate heating, the variations of process parameters that increase these values lead to an enhanced adatom mobility at the target surface and an increased input energy to the substrate, corresponding to the experimental observation of surface roughness reduction, the microstructure transition from the columnar structure to the dense featureless structure, and the enhancement of phase separation. At higher N2 partial pressure or lower working pressure, the modeling results demonstrate an increase in electron temperature, which shifts the discharge balance of Ti species from Ti+ to Ti2+ and results in a higher return fraction of Ti species, corresponding to the higher Al/Ti ratio of deposited films at these conditions. The modeling results are well correlated with the experimental observation of the composition variation and the microstructure transition of deposited TiAlSiN compound films, demonstrating the applicability of this approach in understanding the characteristics of reactive MPPMS discharges as well as the composition and microstructure of deposited compound films. The model for reactive MPPMS discharges has no special limitations and is applicable to high power impulse magnetron sputtering discharges as well.
Toutle/Cowlitz River Sediment Budget
2010-05-18
Discharge Data, Partial Water Year Suspended Sediment Data, Partial Water Year USGS Gage No. Gage Name Drainage Area ( mi2 ) Water Year 1980s 1990s...Sediment mean cfs acre-ft tons/ mi2 tons/acre-ft 1982 - 1987 2,131 1,543,666 44,000 13.1 1988 - 1998 2,082 1,508,160 4,107 1.2 1999 - 2007 2,010
NASA Astrophysics Data System (ADS)
Abdallah, B.; Naddaf, M.; A-Kharroub, M.
2013-03-01
Non-stiochiometric zirconium nitride (ZrNx) thin films have been deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures at different N2 partial pressure ratio. The microstructure, mechanical, electrical and wetting properties of these films are studied by means of X-ray diffraction (XRD), micro-Raman spectroscopy, Rutherford back scattering (RBS) technique, conventional micro-hardness testing, electrical resistivity, atomic force microscopy (AFM) and contact angle (CA) measurements. RBS results and analysis show that the (N/Zr) ratio in the film increases with increasing the N2 partial pressure. A ZrNx film with (Zr/N) ratio in the vicinity of stoichiometric ZrN is obtained at N2 partial pressure of 10%. XRD and Raman results indicate that all deposited films have strained cubic crystal phase of ZrN, regardless of the N2 partial pressure. On increasing the N2 partial pressure, the relative intensity of (1 1 1) orientation with respect to (2 0 0) orientation is seen to decrease. The effect of N2 partial pressure on micro-hardness and the resistivity of the deposited film is revealed and correlated to the alteration of grain size, crystallographic texture, stoichiometry and residual stress developed in the film. In particular, it is found that residual stress and nitrogen incorporation in the film play crucial role in the alteration of micro-hardness and resistivity respectively. In addition, CA and AFM results demonstrate that as N2 partial pressure increases, both the surface hydrophobicity and roughness of the deposited film increase, leading to a significant decrease in the film surface free energy (SFE).
NASA Astrophysics Data System (ADS)
Winter, J.; Esser, H. G.; Könen, L.; Philipps, V.; Reimer, H.; Seggern, J. v.; Schlüter, J.; Vietzke, E.; Waelbroeck, F.; Wienhold, P.; Banno, T.; Ringer, D.; Vepřek, S.
1989-04-01
The liner and limiters of TEXTOR have been coated in situ with a boron containing carbon film using a RG discharge in a throughflow of 0.8 He + 0.1 B 2H 6 +0.1 CH 4. The average film thickness was 30-50 nm, the ratio of boron and carbon in the layer was about 1:1 according to Auger Electron Spectroscopy. Subsequent tokamak discharges are characterized by a small fraction of radiated power (< 0.3) even during high power ICRF heating (2.6 MW, 1.6 s). A concomitant strong increase of the convective power loading of the limiters is observed. Values of Z eff lower than 1.2 are derived from conductivity measurements. The most prominent change in the impurity concentration compared to good conditions in a carbonized surrounding is measured for oxygen. The value OVI/ n¯e of the OVI intensity normalized to the averaged plasma density overlinene decreases by more than a factor of four. The decrease in the oxygen content manifests itself also as a reduction of the CO and CO 2 partial pressures measured during and after the discharge with a sniffer probe. The carbon levels are reduced by a factor of about two as measured by the normalized intensity CII/ overlinene of the CII line and via the ratio of the C fluxes and deuterium fluxes measured at the limiter (CI/D α). The wall shows a pronounced sorption of hydrogen from the plasma, easing the density control and the establishment of low recycling conditions. The beneficial conditions did not show a significant deterioration during more than 200 discharges, including numerous shots at ICRH power levels > 2 MW.
Classification of Partial Discharge Measured under Different Levels of Noise Contamination
2017-01-01
Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD) and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE) cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA) features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN), Adaptive Neuro-Fuzzy Inference System (ANFIS) and Support Vector Machine (SVM). It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination. PMID:28085953
NASA Astrophysics Data System (ADS)
Dong, Xingchen; Zhang, Xiaoxing; Cui, Hao; Zhang, Jun
2017-11-01
Gas insulated switchgear has been widely used in modern electric systems due to its significantly excellent performances such as compact structure and low land occupation as well as the security stability. However, inside defects caused during manufacture process can lead to partial discharge which might develop into serious insulation failure. Online monitoring method on basis of gas sensors is considered a promising way of detecting partial discharge for alarm ahead of time. Research has found that TiO2 nanotubes sensors show good response to SO2, SOF2, SO2F2, the decomposition components as a result of partial discharge. In order to investigate the gas-sensing mechanism of nitrogen-doped TiO2 prepared via plasma treatment methods to SO2, SOF2, and SO2F2, the adsorption structures of both three gas molecules and anatase TiO2 (101) surface were built, and DFT calculations were then carried out for calculation and analysis of adsorption parameters. Adsorption property comparison of anatase TiO2 (101) surface after nitrogen doping with Au doping and without doping shows that nitrogen doping can obviously enhance the adsorption energy for SO2 and SOF2 adsorption and no charge transfer for SO2F2 adsorption, further explaining the adsorption mechanism and doping influence of different doping elements.
Two examples of intelligent systems based on smart materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unsworth, J.
1994-12-31
Two intelligent systems are described which are based on smart materials. The operation of the systems also rely on conventional well known technologies such as electronics, signal conditioning, signal processing, microprocessors and engineering design. However without the smart materials the development and integration into the intelligent systems would not have been possible. System 1 is a partial discharge monitor for on-line continuous checking of the condition of electrical power transformers. The ultrasonic and radio frequency detectors in this system rely on special piezoelectric composite integrated with a compact annular metal ring. Partial discharges set up ultrasonic and radio frequency signalsmore » which are received by the integrated detectors. The signals are amplified, conditioned, signal processed, the time interval between the two signals measured and the level of partial discharge activity averaged and assessed for numerous pairs and alarms triggered on remote control panels if the level is dangerous. The system has the capability of initiating automatic shutdown of the transformer once it is linked into the control computers of the electrical power authority. System 2 is called a Security Cradle and is an intelligent 3D shield designed to use the properties of electro active polymers to prevent hardware hackers from stealing valuable of sensitive information from memory devices (e.g., EPROMS) housed in computer or microprocessor installations.« less
Integrated environmental monitoring and multivariate data analysis-A case study.
Eide, Ingvar; Westad, Frank; Nilssen, Ingunn; de Freitas, Felipe Sales; Dos Santos, Natalia Gomes; Dos Santos, Francisco; Cabral, Marcelo Montenegro; Bicego, Marcia Caruso; Figueira, Rubens; Johnsen, Ståle
2017-03-01
The present article describes integration of environmental monitoring and discharge data and interpretation using multivariate statistics, principal component analysis (PCA), and partial least squares (PLS) regression. The monitoring was carried out at the Peregrino oil field off the coast of Brazil. One sensor platform and 3 sediment traps were placed on the seabed. The sensors measured current speed and direction, turbidity, temperature, and conductivity. The sediment trap samples were used to determine suspended particulate matter that was characterized with respect to a number of chemical parameters (26 alkanes, 16 PAHs, N, C, calcium carbonate, and Ba). Data on discharges of drill cuttings and water-based drilling fluid were provided on a daily basis. The monitoring was carried out during 7 campaigns from June 2010 to October 2012, each lasting 2 to 3 months due to the capacity of the sediment traps. The data from the campaigns were preprocessed, combined, and interpreted using multivariate statistics. No systematic difference could be observed between campaigns or traps despite the fact that the first campaign was carried out before drilling, and 1 of 3 sediment traps was located in an area not expected to be influenced by the discharges. There was a strong covariation between suspended particulate matter and total N and organic C suggesting that the majority of the sediment samples had a natural and biogenic origin. Furthermore, the multivariate regression showed no correlation between discharges of drill cuttings and sediment trap or turbidity data taking current speed and direction into consideration. Because of this lack of correlation with discharges from the drilling location, a more detailed evaluation of chemical indicators providing information about origin was carried out in addition to numerical modeling of dispersion and deposition. The chemical indicators and the modeling of dispersion and deposition support the conclusions from the multivariate statistics. Integr Environ Assess Manag 2017;13:387-395. © 2016 SETAC. © 2016 SETAC.
Plasma Jet Interactions with Liquids in Partial Fulfillment of an NRL Karles Fellowship
2015-11-30
deposition), modify (e.g., chemical functionalization), and etch (in Si technology) materials. In low- pressure non- equilibrium discharge plasmas... equilibrium discharge plasmas, associated with the above processes, the electron population is much more energetic than both the ions and neutral gas...to be crucial to the advancements of these fields1, 2. Background: Atmospheric-pressure, non- equilibrium (APNE) plasmas, like low-pressure plasmas
Relationship between locked modes and thermal quenches in DIII-D
NASA Astrophysics Data System (ADS)
Sweeney, R.; Choi, W.; Austin, M.; Brookman, M.; Izzo, V.; Knolker, M.; La Haye, R. J.; Leonard, A.; Strait, E.; Volpe, F. A.; The DIII-D Team
2018-05-01
Locked modes are known to be one of the major causes of disruptions, but the physical mechanisms by which locking leads to disruptions are not well understood. Here we analyze the evolution of the temperature profile in the presence of multiple coexisting locked modes during partial and full thermal quenches. Partial quenches are often observed to be an initial, distinct stage in the full thermal quench. Near the onset of partial quenches, locked island O-points are observed to align with each other on the midplane, and their widths are sufficient to overlap each other, as indicated by the Chirikov parameter. Energy conservation analysis of one partial thermal quench shows that the energy lost is both radiated in the divertor region, and conducted or convected to the divertor. Nonlinear resistive magnetohydrodynamic simulations support the interpretation of stochastic fields causing a partial axisymmetric collapse, though the simulated temperature profile exhibits less degradation than the experimental profiles. In discharges with minimum values of the safety factor above ∼1.2, locked modes are observed to self-stabilize by inducing, possibly via double tearing modes, a minor disruption that removes their neoclassical drive. These high q min discharges often exhibit relatively low ratios of the plasma internal inductance to the safety factor at 95% of the poloidal flux, which might imply classical stability, in agreement with the decay of the mode when the neoclassical drive is removed.
Effect of oblique channel on discharge characteristics of 200-W Hall thruster
NASA Astrophysics Data System (ADS)
Ding, Yongjie; Peng, Wuji; Sun, Hezhi; Xu, Yu; Wei, Liqiu; Li, Hong; Zeng, Ming; Wang, Fufeng; Yu, Daren
2017-02-01
In an experiment involving a 200-W Hall thruster, partial ionization occurs in the plume area because of the extrapolation of the magnetic field. To improve the thruster performance, the concept of an oblique channel is proposed for improving the ionization degree in the plume area. Calculations performed using a Particle-in-cell (PIC) simulator and the experimental results both show that an oblique channel structure can reduce the wall loss. Compared with a straight channel under similar conditions of the discharge voltage and current, the ionization degree in the plume area, thrust, specific impulse, propellant utilization, and anode efficiency are improved by ˜20%. The oblique channel is an important design consideration for improving the partial ionization of the plume area in the thruster.
Analysis of flow near a dug well in an unconfined aquifer
NASA Astrophysics Data System (ADS)
Sridharan, K.; Sathyanarayana, D.; Reddy, A. Siva
1990-11-01
A numerical analysis of flow to a dug well in an unconfined aquifer is made, taking into account well storage, elastic storage release, gravity drainage, anisotropy, partial penetration, vertical flow and seepage surface at the well face, and treating the water table in the aquifer and water level in the well as unknown boundaries. The pumped discharge is maintained constant. The solution is obtained by a two-level iterative scheme. The effects of governing parameters on the drawdown, development of seepage surface and contribution from aquifer flow to the total discharge are discussed. The degree of anisotropy and partial penetration are found to be the parameters which affect the flow characteristics most significantly. The effect of anisotropy on the development of seepage surface is very pronounced.
Pope, G.L.; Agajanian, J.; Caldwell, L.A.; Rockwell, G.L.
2004-01-01
Water-resources data for the 2003 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 193 gaging stations and 11 crest-stage partial-record stations, stage and contents for 22 lakes and reservoirs, gage-height records for 2 stations, water quality for 47 streamflow-gaging stations and 12 partial-record stations, and precipitation data for 1 station. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Agajanian, J.; Rockwell, G.L.; Anderson, S.W.; Pope, G.L.
2002-01-01
Water-resources data for the 2001 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 180 gaging stations and 13 crest-stage partial-record stations, stage and contents for 20 lakes and reservoirs, gage-height records for 2 stations, water quality for 37 streamflow-gaging stations and 2 partial-record stations, and precipitation data for 3 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Rockwell, G.L.; Pope, G.L.; Agajanian, J.; Caldwell, L.A.
2003-01-01
Water-resources data for the 2002 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 188 gaging stations and 10 crest-stage partial-record stations, stage and contents for 19 lakes and reservoirs, gage-height records for 2 stations, water quality for 39 streamflow-gaging stations and 11 partial-record stations, and precipitation data for 1 station. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Hayes, P.D.; Agajanian, J.A.; Rockwell, G.L.
1995-01-01
Water resources data for the 1994 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 143 streamflow-gaging stations, 15 crest-stage partial-record streamflow stations; (2) stage and contents records for 20 lakes and reservoirs; (3) water quality records for 19 streamflow-gaging stations and 2 partial-record stations; and ( 4) precipitation records for 8 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Agajanian, J.; Caldwell, L.A.; Rockwell, G.L.; Pope, G.L.
2005-01-01
Water-resources data for the 2004 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 195 gaging stations and 10 crest-stage partial-record stations, stage and contents for 25 lakes and reservoirs, gage-height records for 2 stations, water quality for 47 streamflow-gaging stations and 7 partial-record stations, and precipitation data for 5 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Polinoski, K.G.; Hoffman, E.B.; Smith, G.B.; Bowers, J.C.
1989-01-01
Water resources data for the 1988 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 134 gaging stations; stage and contents for 17 lakes and reservoirs; and water quality for 24 streams. Also included are 10 crest-stage partial-record stations, 5 miscellaneous measurement sites, and 16 water-quality partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Bowers, J.C.; Jensen, R.M.; Hoffman, E.B.
1991-01-01
Water resources data for the 1990 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 157 streamflow-gaging stations, 16 crest-stage partial-record streamflow stations, and 2miscellaneous measurement stations; stage and contents records for 16 lakes and reservoirs; water-quality records for 19 streamflow-gaging stations, 2 partial-record stations; and precipitation records for 13 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Agajanian, J.A.; Rockwell, G.L.; Hayes, P.D.
1996-01-01
Water resources data for the 1995 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 141 streamflow-gaging stations, 6 crest-stage partial-record streamflow stations; (2) stage and contents records for 20 lakes and reservoirs; (3) water quality records for 21 streamflow-gaging stations and 3 partial-record stations; and (4) precipitation records for 1 station. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Bowers, J.C.; McConaughy, C.E.; Polinoski, K.G.; Smith, G.B.
1988-01-01
Water resources data for the 1987 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 134 gaging stations; stage and contents for 16 lakes and reservoirs; and water quality for 16 streams. Also included are 10 crest-stage partial-record stations, 3 miscellaneous measurement sites, and 10 water-quality partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Hoffman, E.B.; Bowers, J.C.; Jensen, R.M.
1990-01-01
Water resources data for the 1989 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 137 gaging stations; stage and contents for 15 lakes and reservoirs; water quality for 25 streams; and precipitation for 8 gaging stations. Also included are 15 crest-stage partial-record stations, 7 miscellaneous measurement sites, and 5 water-quality partial record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Rockwell, G.L.; Hayes, P.D.; Agajanian, J.A.
1997-01-01
Water-resources data for the 1996 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 149 gaging stations and 6 crest-stage partial-record stations, stage and contents for 21 lakes and reservoirs, gage height records for 1 station, water quality for 19 streamflow-gaging stations and 17 partial record stations, and precipitation data for 4 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Anderson, S.W.; Agajanian, J.; Rockwell, G.L.
2001-01-01
Water-resources data for the 2000 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 175 gaging stations and 13 crest-stage partial-record stations, stage and contents for 20 lakes and reservoirs, gage-height records for 2 stations, water quality for 27 streamflow-gaging stations and 3 partial-record stations, and precipitation data for 4 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Discharge formation in a XеCl laser pumped by high specific power
NASA Astrophysics Data System (ADS)
Panchenko, Yu. N.; Losev, V. F.
2013-02-01
Stable glow of the discharge of various types in the gas mixture of a XeCl laser is investigated for specific pumping power in the range 1.2-4.6 MW/cm3 and pulse duration of 40 ns. It is demonstrated that formation of partially homogeneous plasma with many intensive cathode spots on the electrode allows the maximum energy and duration of the lasing pulse to be obtained with laser efficiency of 2.4%. It is revealed that for the specific pumping powers up to 1.5 MW/cm3, a very homogeneous volume discharge with a small number of lowintensive cathode spots is formed in the discharge gap. With further increase in the specific pumping power exceeding 4.5 MW/cm3, current microinhomogeneities are formed in the volume discharge of this type leading to lasing breakdown.
AC Glow Discharge Plasma in N2O
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yousif, F. B.; Martinez, H.; Robledo-Martinez, A.
2006-12-04
This paper considers the optical and electrical characterization of AC glow discharge plasma in the abnormal glow mode used for optical emission spectroscopy. The total discharge current and applied voltage are measured using conventional techniques. The electrical characteristics of the planer-cathode glow discharge confirmed that the plasma is operating at abnormal discharge mode characterized by the increases in the operating voltage as the current was raised under given pressure. Optical emission spectroscopy was used to determine the main emission lines of the glow discharge plasma of N2O at pressures between 0.5 and 4.0 Torr. It shows that the discharge emissionmore » range is mainly within 300-400 nm. The emission lines correspond to NO, O2, and O{sub 2}{sup +} are the dominant lines in the glow discharge plasma in the present study. Intensity of the emission lines show linear increase with the discharge current up to 0.4 A followed by saturation at higher currents. No emission lines were observed in this work corresponding to atomic oxygen or nitrogen.« less
NASA Astrophysics Data System (ADS)
Brusseau, M. L.; Carroll, K. C.; Baker, J. B.; Allen, T.; DiGuiseppi, W.; Hatton, J.; Morrison, C.; Russo, A. E.; Berkompas, J. L.
2011-12-01
A large-scale permanganate-based in-situ chemical oxidation (ISCO) effort has been conducted over the past ten years at a federal Superfund site in Tucson, AZ, for which trichloroethene (TCE) is the primary contaminant of concern. Remediation performance was assessed by examining the impact of treatment on contaminant mass discharge, an approach that has been used for only a very few prior ISCO projects. Contaminant mass discharge tests were conducted before and after permanganate injection to measure the impact at the source-zone scale. The results indicate that ISCO caused a significant reduction in mass discharge (approximately 75%). The standard approach of characterizing discharge at the source-zone scale was supplemented with additional characterization at the plume scale, which was evaluated by examining the change in contaminant mass discharge associated with the pump-and-treat system. The integrated contaminant mass discharge decreased by approximately 70%, consistent with the source-zone-scale measurements. The integrated mass discharge rebounded from 0.1 to 0.2 Kg/d within one year after cessation of permanganate injections, after which it has been stable for several years. Collection of the integrated contaminant mass discharge data throughout the ISCO treatment period provided a high-resolution, real-time analysis of the site-wide impact of ISCO, thereby linking source-zone remediation to impacts on overall risk. The results indicate that ISCO was successful in reducing contaminant mass discharge at this site, which comprises a highly heterogeneous subsurface environment. Analysis of TCE sediment concentration data for core material collected before and after ISCO supports the hypothesis that the remaining mass discharge is associated in part with poorly-accessible contaminant mass residing within lower-permeability zones.
Brusseau, M L; Carroll, K C; Allen, T; Baker, J; Diguiseppi, W; Hatton, J; Morrison, C; Russo, A; Berkompas, J
2011-06-15
A large-scale permanganate-based in situ chemical oxidation (ISCO) effort has been conducted over the past ten years at a federal Superfund site in Tucson, AZ, for which trichloroethene (TCE) is the primary contaminant of concern. Remediation performance was assessed by examining the impact of treatment on contaminant mass discharge, an approach that has been used for only a very few prior ISCO projects. Contaminant mass discharge tests were conducted before and after permanganate injection to measure the impact at the source-zone scale. The results indicate that ISCO caused a significant reduction in mass discharge (approximately 75%). The standard approach of characterizing discharge at the source-zone scale was supplemented with additional characterization at the plume scale, which was evaluated by examining the change in contaminant mass discharge associated with the pump-and-treat system. The integrated contaminant mass discharge decreased by approximately 70%, consistent with the source-zone-scale measurements. The integrated mass discharge rebounded from 0.1 to 0.2 kg/d within one year after cessation of permanganate injections, after which it has been stable for several years. Collection of the integrated contaminant mass discharge data throughout the ISCO treatment period provided a high-resolution, real-time analysis of the site-wide impact of ISCO, thereby linking source-zone remediation to impacts on overall risk. The results indicate that ISCO was successful in reducing contaminant mass discharge at this site, which comprises a highly heterogeneous subsurface environment. Analysis of TCE sediment concentration data for core material collected before and after ISCO supports the hypothesis that the remaining mass discharge is associated in part with poorly accessible contaminant mass residing within lower-permeability zones.
Fewell, Laura K; Levinson, Cheri A; Stark, Lynn
2017-06-01
This retrospective study explores depression, worry, psychosocial functioning, and change in body mass index (BMI) as predictors of eating disorder (ED) symptomatology and BMI at discharge and 1-year follow-up from a residential and partial hospitalization ED treatment center. Participants were 423 male and female patients receiving treatment at an ED treatment center. Results indicate significant improvement in ED symptomatology, psychological impairment, and change in BMI (in patients with anorexia nervosa) at treatment discharge and follow-up compared to treatment admission (ps < 0.001). Depression and worry predicted ED symptomatology and psychological impairment at discharge (ps < 0.05). Depression, worry, and psychosocial functioning predicted ED symptomatology and psychological impairment at 1-year follow-up (ps < 0.001). Change in BMI was not a significant predictor of outcome. Depression, worry, and psychosocial functioning each play a role in treatment outcomes and may help clarify who might benefit from treatment. Clinicians in ED treatment centers should consider these as areas of focus for improved outcomes.
Correlating Lithium Hydroxyl Accumulation with Capacity Retention in V2O5 Aerogel Cathodes.
Wangoh, Linda W; Huang, Yiqing; Jezorek, Ryan L; Kehoe, Aoife B; Watson, Graeme W; Omenya, Fredrick; Quackenbush, Nicholas F; Chernova, Natasha A; Whittingham, M Stanley; Piper, Louis F J
2016-05-11
V2O5 aerogels are capable of reversibly intercalating more than 5 Li(+)/V2O5 but suffer from lifetime issues due to their poor capacity retention upon cycling. We employed a range of material characterization and electrochemical techniques along with atomic pair distribution function, X-ray photoelectron spectroscopy, and density functional theory to determine the origin of the capacity fading in V2O5 aerogel cathodes. In addition to the expected vanadium redox due to intercalation, we observed LiOH species that formed upon discharge and were only partially removed after charging, resulting in an accumulation of electrochemically inactive LiOH over each cycle. Our results indicate that the tightly bound water that is necessary for maintaining the aerogel structure is also inherently responsible for the capacity fade.
Correlating Lithium Hydroxyl Accumulation with Capacity Retention in V 2 O 5 Aerogel Cathodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wangoh, Linda W.; Huang, Yiqing; Jezorek, Ryan L.
V 2O 5 aerogels are capable of reversibly intercalating more than 5 Li +/V 2O 5 but suffer from lifetime issues due to their poor capacity retention upon cycling. We employed a range of material characterization and electrochemical techniques along with atomic pair distribution function, X-ray photoelectron spectroscopy, and density functional theory to determine the origin of the capacity fading in V 2O 5 aerogel cathodes. In addition to the expected vanadium redox due to intercalation, we observed LiOH species that formed upon discharge and were only partially removed after charging, resulting in an accumulation of electrochemically inactive LiOH overmore » each cycle. Our results indicate that the tightly bound water that is necessary for maintaining the aerogel structure is also inherently responsible for the capacity fade.« less
Muhlestein, Whitney E; Akagi, Dallin S; Chotai, Silky; Chambless, Lola B
2017-08-01
Racial disparities exist in health care, frequently resulting in unfavorable outcomes for minority patients. Here, we use guided machine learning (ML) ensembles to model the impact of race on discharge disposition and length of stay (LOS) after brain tumor surgery from the Healthcare Cost and Utilization Project National Inpatient Sample. We performed a retrospective cohort study of 41,222 patients who underwent craniotomies for brain tumors from 2002 to 2011 and were registered in the National Inpatient Sample. Twenty-six ML algorithms were trained on prehospitalization variables to predict non-home discharge and extended LOS (>7 days) after brain tumor resection, and the most predictive algorithms combined to create ensemble models. Partial dependence analysis was performed to measure the independent impact of race on the ensembles. The guided ML ensembles predicted non-home disposition (area under the curve, 0.796) and extended LOS (area under the curve, 0.824) with good discrimination. Partial dependence analysis showed that black race increases the risk of non-home discharge and extended LOS over white race by 6.9% and 6.5%, respectively. Other, nonblack race increases the risk of extended LOS over white race by 6.0%. The impact of race on these outcomes is not seen when analyzing the general inpatient or general operative population. Minority race independently increases the risk of extended LOS and black race increases the risk of non-home discharge in patients undergoing brain tumor resection, a finding not mimicked in the general inpatient or operative population. Recognition of the influence of race on discharge and LOS could generate interventions that may improve outcomes in this population. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higashiguchi, Takeshi; Yugami, Noboru; CREST, Japan Science and Technology Agency, 4-1-8 Honcho, Kanagawa, Saitama 332-0012
2010-04-15
We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Nomarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 400 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.
Two cases of childhood narcolepsy mimicking epileptic seizures in video-EEG/EMG.
Yanagishita, Tomoe; Ito, Susumu; Ohtani, Yui; Eto, Kaoru; Kanbayashi, Takashi; Oguni, Hirokazu; Nagata, Satoru
2018-06-06
Narcolepsy is characterized by excessive sleepiness, hypnagogic hallucinations, and sleep paralysis, and can occur with or without cataplexy. Here, we report two children with narcolepsy presenting with cataplexy mimicking epileptic seizures as determined by long-term video-electroencephalography (EEG) and electromyography (EMG) monitoring. Case 1 was a 15-year-old girl presenting with recurrent episodes of "convulsions" and loss of consciousness, who was referred to our hospital with a diagnosis of epilepsy showing "convulsions" and "complex partial seizures". The long-term video-polygraph showed a clonic attack lasting for 15 s, which corresponded to 1-2 Hz with interruption of mentalis EMG discharges lasting for 70-300 ms without any EEG changes. Narcolepsy was suspected due to the attack induced by hearty laughs and the presence of sleep attacks, and confirmed by low orexin levels in cerebrospinal fluid (CSF). Case 2 was an 11-year-old girl presenting with recurrent episodes of myoclonic attacks simultaneously with dropping objects immediately after hearty laughs, in addition to sleep attacks, hypnagogic hallucinations, and sleep paralysis. The long-term video-polygraph showed a subtle attack, characterized by dropping chopsticks from her hand, which corresponded to an interruption of ongoing deltoid EMG discharges lasting 140 ms without any EEG changes. A diagnosis of narcolepsy was confirmed by the low orexin levels in CSF. These cases demonstrate that children with narcolepsy may have attacks of cataplexy that resemble clonic or myoclonic seizures. Copyright © 2018 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Electrophysiology of neurones of the inferior mesenteric ganglion of the cat.
Julé, Y; Szurszewski, J H
1983-01-01
Intracellular recordings were obtained from cells in vitro in the inferior mesenteric ganglia of the cat. Neurones could be classified into three types: non-spontaneous, irregular discharging and regular discharging neurones. Non-spontaneous neurones had a stable resting membrane potential and responded with action potentials to indirect preganglionic nerve stimulation and to intracellular injection of depolarizing current. Irregular discharging neurones were characterized by a discharge of excitatory post-synaptic potentials (e.p.s.p.s.) which sometimes gave rise to action potentials. This activity was abolished by hexamethonium bromide, chlorisondamine and d-tubocurarine chloride. Tetrodotoxin and a low Ca2+ -high Mg2+ solution also blocked on-going activity in irregular discharging neurones. Regular discharging neurones were characterized by a rhythmic discharge of action potentials. Each action potential was preceded by a gradual depolarization of the intracellularly recorded membrane potential. Intracellular injection of hyperpolarizing current abolished the regular discharge of action potential. No synaptic potentials were observed during hyperpolarization of the membrane potential. Nicotinic, muscarinic and adrenergic receptor blocking drugs did not modify the discharge of action potentials in regular discharging neurones. A low Ca2+ -high Mg2+ solution also had no effect on the regular discharge of action potentials. Interpolation of an action potential between spontaneous action potentials in regular discharging neurones reset the rhythm of discharge. It is suggested that regular discharging neurones were endogenously active and that these neurones provided synaptic input to irregular discharging neurones. PMID:6140310
Electrophysiology of neurones of the inferior mesenteric ganglion of the cat.
Julé, Y; Szurszewski, J H
1983-11-01
Intracellular recordings were obtained from cells in vitro in the inferior mesenteric ganglia of the cat. Neurones could be classified into three types: non-spontaneous, irregular discharging and regular discharging neurones. Non-spontaneous neurones had a stable resting membrane potential and responded with action potentials to indirect preganglionic nerve stimulation and to intracellular injection of depolarizing current. Irregular discharging neurones were characterized by a discharge of excitatory post-synaptic potentials (e.p.s.p.s.) which sometimes gave rise to action potentials. This activity was abolished by hexamethonium bromide, chlorisondamine and d-tubocurarine chloride. Tetrodotoxin and a low Ca2+ -high Mg2+ solution also blocked on-going activity in irregular discharging neurones. Regular discharging neurones were characterized by a rhythmic discharge of action potentials. Each action potential was preceded by a gradual depolarization of the intracellularly recorded membrane potential. Intracellular injection of hyperpolarizing current abolished the regular discharge of action potential. No synaptic potentials were observed during hyperpolarization of the membrane potential. Nicotinic, muscarinic and adrenergic receptor blocking drugs did not modify the discharge of action potentials in regular discharging neurones. A low Ca2+ -high Mg2+ solution also had no effect on the regular discharge of action potentials. Interpolation of an action potential between spontaneous action potentials in regular discharging neurones reset the rhythm of discharge. It is suggested that regular discharging neurones were endogenously active and that these neurones provided synaptic input to irregular discharging neurones.
Curran, Christopher A.; Eng, Ken; Konrad, Christopher P.
2012-01-01
Regional low-flow regression models for estimating Q7,10 at ungaged stream sites are developed from the records of daily discharge at 65 continuous gaging stations (including 22 discontinued gaging stations) for the purpose of evaluating explanatory variables. By incorporating the base-flow recession time constant τ as an explanatory variable in the regression model, the root-mean square error for estimating Q7,10 at ungaged sites can be lowered to 72 percent (for known values of τ), which is 42 percent less than if only basin area and mean annual precipitation are used as explanatory variables. If partial-record sites are included in the regression data set, τ must be estimated from pairs of discharge measurements made during continuous periods of declining low flows. Eight measurement pairs are optimal for estimating τ at partial-record sites, and result in a lowering of the root-mean square error by 25 percent. A low-flow survey strategy that includes paired measurements at partial-record sites requires additional effort and planning beyond a standard strategy, but could be used to enhance regional estimates of τ and potentially reduce the error of regional regression models for estimating low-flow characteristics at ungaged sites.
Characteristics of electromagnetic interference generated by arc discharges. [in spacecraft
NASA Technical Reports Server (NTRS)
Leung, Philip
1986-01-01
Electromagnetic interference (EMI) signatures resulting from arc discharges are characterized, and the effects of electrostatic discharges (ESDs) on the design of spacecraft systems are investigated. EMI characterization experiments were performed on Mylar, Teflon, Kapton, fused silica, and fiberglass in a vacuum chamber with acrylic walls; the experimental design and procedures are described. Discharge current pulses and RF spectra generated by the sample materials are examined. The relation between the magnitude of EMI generated during an ESD event and the material, environment, and geometry is studied. The solar-array/plasma interaction is analyzed; particular attention is given to the rate of discharge as a function of plasma density. The physical mechanisms of ESD-generated EMI are discussed. The data reveal that ESD parameters are dependent on the test environment.
Characterization testing of a 40 AHR bipolar nickel-hydrogen battery
NASA Astrophysics Data System (ADS)
Brewer, Jeffrey C.; Manzo, Michelle A.; Gemeiner, Russel P.
1989-12-01
Extensive characterization testing has been done on a second 40 amp-hour (Ahr), 10-cell bipolar nickel-hydrogen (Ni-H2) battery to study the effects of such operating parameters as charge and discharge rates, temperature, and pressure, on capacity, Ahr and watt-hour (Whr) efficiencies, end-of-charge (EOC) and mid-point discharge voltages. Testing to date has produced many interesting results, with the battery performing well throughout all of the test matrix except during the high-rate (5C and 10C) discharges, where poorer than expected results were observed. The exact cause of this poor performance is, as yet, unknown. Small scale 2 x 2 inch battery tests are to be used in studying this problem. Low earth orbit (LEO) cycle life testing at a 40 percent depth of discharge (DOD) and 10 C is scheduled to follow the characterization testing.
Characterization testing of a 40 AHR bipolar nickel-hydrogen battery
NASA Technical Reports Server (NTRS)
Brewer, Jeffrey C.; Manzo, Michelle A.; Gemeiner, Russel P.
1989-01-01
Extensive characterization testing has been done on a second 40 amp-hour (Ahr), 10-cell bipolar nickel-hydrogen (Ni-H2) battery to study the effects of such operating parameters as charge and discharge rates, temperature, and pressure, on capacity, Ahr and watt-hour (Whr) efficiencies, end-of-charge (EOC) and mid-point discharge voltages. Testing to date has produced many interesting results, with the battery performing well throughout all of the test matrix except during the high-rate (5C and 10C) discharges, where poorer than expected results were observed. The exact cause of this poor performance is, as yet, unknown. Small scale 2 x 2 inch battery tests are to be used in studying this problem. Low earth orbit (LEO) cycle life testing at a 40 percent depth of discharge (DOD) and 10 C is scheduled to follow the characterization testing.
Characterization testing of a 40 ampere hour bipolar nickel-hydrogen battery
NASA Technical Reports Server (NTRS)
Brewer, Jeffrey C.; Manzo, Michelle A.; Gemeiner, Russel P.
1990-01-01
Extensive characterization testing has been done on a second 40-ampere hour (A h), 10-cell, bipolar nickel-hydrogen (Ni-H2) battery, to study the effects of operating parameters such as charge and discharge rates, temperature, and pressure on capacity, A h and watt hour (W h) efficiencies, and end-of-charge and midpoint discharge voltages. Testing to date has produced many interesting results, with the battery performing well throughout the test matrix except during the high-rate (5 C and 10 C) discharges, where poorer than expected results were observed. The exact cause of this poor performance is, as yet, unknown. Small scale 2 in. x 2 in. battery tests are to be used in studying this problem. Low earth orbit cycle life testing at a 40-percent depth of discharge and 10 C is scheduled to follow the characterization testing.
Partial discharges and breakdown in C3F8
NASA Astrophysics Data System (ADS)
Koch, M.; Franck, C. M.
2014-10-01
Traditional search processes of gases or gas mixtures for replacing SF6 involve time consuming measurements of partial discharges and breakdown behaviour for several voltage waveforms and different field configurations. Recently a model for prediction of this behaviour for SF6 was described in literature. The model only requires basic properties of the gas such as the critical field strength and the effective ionization coefficient, which can be obtained by swarm parameter measurements, and thermodynamic properties, which can be calculated. In this paper, we show for the well-known and electronegative gas octafluoropropane (C3F8) that it is possible to transfer the model developed for SF6 to this gas to describe the breakdown behaviour of C3F8. Thus the model can be beneficial in the screening process of new insulation gases.
Mullen, J.R.; Hayes, P.D.; Agajanian, J.A.
1994-01-01
Water resources data for the 1993 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 156 streamflow-gaging stations, 12 crest-stage partial-record streamflow stations, and 5 miscellaneous measurement stations; (2) stage and contents records for 26 lakes and reservoirs; (3) water-quality records for 17 streamflow-gaging stations and 6 partial-record stations; and (4) precipitation records for 10 stations . These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
NASA Astrophysics Data System (ADS)
Hozumi, Naohiro; Nishioka, Koji; Suematsu, Takeshi; Murakami, Yoshinobu; Nagao, Masayuki; Sakata, Hiroshi
Feasibility of self-healing insulation system was studied. A silicone rubber without filler was mounted on a glass substrate with a needle electrode. An ac voltage with 4 kV in rms was applied. The voltage was cut off when the tree had propagated into 150 micrometers in length. After the cut-off, the partial discharge inception voltage was periodically observed. The partial discharge inception voltage had once reduced into as low as 2 kV. However, it gradually increased with time, and finally exceeded the tree inception voltage (4 kV) when 30 - 60 hours had passed. It was also observed by optical microscope that the tree gradually disappeared in parallel with the recovery of the partial discharge inception voltage. The same phenomenon was observed even if 1 kV ac voltage had been continuously applied during the process of the recovery. A simulation using a needle-shaped void was performed in order to clarify the mechanism of the self-healing effect. It was observed that the tip of the needle-shaped void gradually got wet with a liquid material. It would be the result of "bleed-out" of the low molecular component included in the rubber. The tip of the void was finally filled with the liquid, however, the rest of the needle-shaped void stayed without being filled. In this type of tree, it was suggested that the self-healing effect is expected if the diameter of the tree did not exceed ca. 5 micrometers.
Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors.
Zhang, Chongxing; Dong, Ming; Ren, Ming; Huang, Wenguang; Zhou, Jierui; Gao, Xuze; Albarracín, Ricardo
2018-02-11
Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of metal-enclosed switchgear. The transient earth voltage method, an effective non-intrusive method, has substantial engineering application value for estimating the insulation condition of switchgear. However, the practical application effectiveness of TEV detection is not satisfactory because of the lack of a TEV detection application method, i.e., a method with sufficient technical cognition and analysis. This paper proposes an innovative online PD detection system and a corresponding application strategy based on an intelligent feedback distributed TEV wireless sensor network, consisting of sensing, communication, and diagnosis layers. In the proposed system, the TEV signal or status data are wirelessly transmitted to the terminal following low-energy signal preprocessing and acquisition by TEV sensors. Then, a central server analyzes the correlation of the uploaded data and gives a fault warning level according to the quantity, trend, parallel analysis, and phase resolved partial discharge pattern recognition. In this way, a TEV detection system and strategy with distributed acquisition, unitized fault warning, and centralized diagnosis is realized. The proposed system has positive significance for reducing the fault rate of medium voltage switchgear and improving its operation and maintenance level.
Cao, Xiaoyu; Mo, Lulu; Zhu, Limin; Xie, Lingling
2017-01-01
Li3V2(PO4)3−xBrx/carbon (x = 0.08, 0.14, 0.20, and 0.26) composites as cathode materials for lithium-ion batteries were prepared through partially substituting PO43− with Br−, via a rheological phase reaction method. The crystal structure and morphology of the as-prepared composites were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM), and electrochemical properties were evaluated by charge/discharge cycling and electrochemical impedance spectroscopy (EIS). XRD results reveal that the Li3V2(PO4)3−xBrx/carbon composites with solid solution phase are well crystallized and have the same monoclinic structure as the pristine Li3V2(PO4)3/carbon composite. It is indicated by SEM images that the Li3V2(PO4)3−xBrx/carbon composites possess large and irregular particles, with an increasing Br− content. Among the Li3V2(PO4)3−xBrx/carbon composites, the Li3V2(PO4)2.86Br0.14/carbon composite shows the highest initial discharge capacity of 178.33 mAh·g−1 at the current rate of 30 mA·g−1 in the voltage range of 4.8–3.0 V, and the discharge capacity of 139.66 mAh·g−1 remains after 100 charge/discharge cycles. Even if operated at the current rate of 90 mA·g−1, Li3V2(PO4)2.86Br0.14/carbon composite still releases the initial discharge capacity of 156.57 mAh·g−1, and the discharge capacity of 123.3 mAh·g−1 can be maintained after the same number of cycles, which is beyond the discharge capacity and cycleability of the pristine Li3V2(PO4)3/carbon composite. EIS results imply that the Li3V2(PO4)2.86Br0.14/carbon composite demonstrates a decreased charge transfer resistance and preserves a good interfacial compatibility between solid electrode and electrolyte solution, compared with the pristine Li3V2(PO4)3/carbon composite upon cycling. PMID:28336886
Water resources data West Virginia water wear 2001
Ward, S.M.; Taylor, B.C.; Crosby, G.R.
2002-01-01
Water-resources data for the 2001 water year for West Virginia consist of records of discharge and water quality of streams and water levels of observation wells. This report contains discharge records for 65 streamflow-gaging stations; discharge records provided by adjacent states for 7 streamflow-gaging stations; annual maximum discharge at 18 crest-stage partial-record stations; water-quality records for 4 stations; and water-level records for 10 observation wells. Locations of these sites are shown on figures 4 and 5. Additional water data were collected at various sites, not involved in the systematic data collection program, and are published as miscellaneous sites. These data represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in West Virginia.
Generation and Reduction of NOx on Air-Fed Ozonizers
NASA Astrophysics Data System (ADS)
Ehara, Yoshiyasu; Amemiya, Yusuke; Yamamoto, Toshiaki
A generation and reduction of NOx on air-fed ozonizers using a ferroelectric packed bed reactor have been experimentally investigated. The reactors packed with CaTiO3, SrTiO3 and BaTiO3 pellets are examined for ozone generation. An ac voltage is applied to the reactor to generate partial discharge. Ozone concentration and the different nitrogen oxides at downstream of the packed bed reactor were measured with UV absorption ozone monitor and a Fourier transform infrared spectroscope respectively. The dielectric constant of packed ferroelectric pellets influences the discharge characteristic, ozone and NOx generations are varied by the dielectric constant value. Focusing on a discharge pulse current and maximum discharge magnitude, the ferroelectric packed bed plasma reactors have been evaluated on nitrogen oxide and ozone generated concentrations.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Yim, John; Herman, Daniel; Peterson, Peter Y.; Williams, George J.; Gilland, James; Hofer, Richard; Mikellides, Ioannis
2016-01-01
NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front magnetic pole cover thruster configuration with the thruster body electrically tied to cathode, and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68% and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the discharge current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability were mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 1×10-5 Torr-Xe (for thruster flow rates of 20.5 mg/s). Power spectral density analysis of the discharge current waveforms showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant breathing mode frequency. Finally, IVB maps of the TDU-1 thruster indicated that the discharge current became more oscillatory with higher discharge current peak-to-peak and RMS values with increased facility background pressure at lower thruster mass flow rates; thruster operation at higher flow rates resulted in less change to the thruster's IVB characteristics with elevated background pressure.
Relationship between locked modes and thermal quenches in DIII-D
Sweeney, R.; Choi, W.; Austin, M.; ...
2018-03-28
Locked modes are known to be one of the major causes of disruptions, but the physical mechanisms by which locking leads to disruptions are not well understood. For this study, we analyze the evolution of the temperature profile in the presence of multiple coexisting locked modes during partial and full thermal quenches. Partial quenches are often observed to be an initial, distinct stage in the full thermal quench. Near the onset of partial quenches, locked island O-points are observed to align with each other on the midplane, and their widths are sufficient to overlap each other, as indicated by themore » Chirikov parameter. Energy conservation analysis of one partial thermal quench shows that the energy lost is both radiated in the divertor region, and conducted or convected to the divertor. Nonlinear resistive magnetohydrodynamic simulations support the interpretation of stochastic fields causing a partial axisymmetric collapse, though the simulated temperature profile exhibits less degradation than the experimental profiles. In discharges with minimum values of the safety factor above ~1.2, locked modes are observed to self-stabilize by inducing, possibly via double tearing modes, a minor disruption that removes their neoclassical drive. These high q min discharges often exhibit relatively low ratios of the plasma internal inductance to the safety factor at 95% of the poloidal flux, which might imply classical stability, in agreement with the decay of the mode when the neoclassical drive is removed.« less
Relationship between locked modes and thermal quenches in DIII-D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sweeney, R.; Choi, W.; Austin, M.
Locked modes are known to be one of the major causes of disruptions, but the physical mechanisms by which locking leads to disruptions are not well understood. For this study, we analyze the evolution of the temperature profile in the presence of multiple coexisting locked modes during partial and full thermal quenches. Partial quenches are often observed to be an initial, distinct stage in the full thermal quench. Near the onset of partial quenches, locked island O-points are observed to align with each other on the midplane, and their widths are sufficient to overlap each other, as indicated by themore » Chirikov parameter. Energy conservation analysis of one partial thermal quench shows that the energy lost is both radiated in the divertor region, and conducted or convected to the divertor. Nonlinear resistive magnetohydrodynamic simulations support the interpretation of stochastic fields causing a partial axisymmetric collapse, though the simulated temperature profile exhibits less degradation than the experimental profiles. In discharges with minimum values of the safety factor above ~1.2, locked modes are observed to self-stabilize by inducing, possibly via double tearing modes, a minor disruption that removes their neoclassical drive. These high q min discharges often exhibit relatively low ratios of the plasma internal inductance to the safety factor at 95% of the poloidal flux, which might imply classical stability, in agreement with the decay of the mode when the neoclassical drive is removed.« less
A Study of Discharge Coefficient in Bileaflet Valves
2001-10-25
Granados J. Garcia MA. Luque I. Concha M. “Conservative operation for mitral stenosis with densely fibrosed or partially calcified valves. An eight...for aortic valves, whereas a lower value (around 0.7) has been proposed for valves mounted in the mitralic position, on account of the larger upstream...section; in the mitral position, then, a valve will have a smaller discharge coefficient (or Aeff/A ratio) than in the aortic position. Using dC =1
Gregory, E; Engel, K; Pfaff, D
1975-07-01
Male hamsters approach sources of odors from female hamster vaginal discharges and spend significantly more time around these odor sources than around control locations in the test box. This preference for female hamster vaginal odors appears in sexually inexperienced as well as experienced males, even in individuals isolated from females since the time of weaning. Castration significantly reduces the sex odor preference, and treatment with testosterone propionate partially restores it.
Hunt, Randall J.; Walker, John F.; Krabbenhoft, David P.
1999-01-01
Although considered the most important component for the establishment and persistence of wetlands, hydrology has been hard to characterize and linkages between hydrology and other environmental conditions are often poorly understood. In this work, methods for characterizing a wetland’s hydrology from hydrographs were developed, and the importance of ground water to the physical and geochemical conditions in the root zone was investigated. Detailed sampling of nearly continuous hydrographs showed that sites with greater ground-water discharge had higher water tables and more stable hydrographs. Subsampling of the continuous hydrograph failed to characterize the sites correctly, even though the wetland complex is located in a strong regional ground-water-discharge area. By comparing soil-moisture-potential measurements to the water-table hydrograph at one site, we noted that the amount of root-zone saturation was not necessarily driven by the water-table hydrograph but can be a result of other soil parameters (i.e., soil texture and associated capillary fringe). Ground-water discharge was not a significant determinant of maximum or average temperatures in the root zone. High ground-water discharge was associated with earliest date of thaw and shortest period of time that the root zone was frozen, however. Finally, the direction and magnitude of shallow ground-water flow was found to affect the migration and importance of a geochemical species. Areas of higher ground-water discharge had less downward penetration of CO2 generated in the root zone. In contrast, biotically derived CO2 was able to penetrate the deeper ground-water system in areas of ground-water recharge. Although ground-water flows are difficult to characterize, understanding these components is critical to the success of wetland restoration and creation efforts.
Particulate and aerosol detector
NASA Technical Reports Server (NTRS)
Wortman, J. J.; Donovan, R. P.; Brooks, A. D.; Monteith, L. K.; Kinard, W. H.; Oneil, R. L. (Inventor)
1976-01-01
A device is described for counting aerosols and sorting them according to either size, mass or energy. The component parts are an accelerator, a capacitor sensor and a readout. The accelerator is a means for accelerating the aerosols toward the face of the capacitor sensor with such force that they partially penetrate the capacitor sensor, momentarily discharging it. The readout device is a means for counting the number of discharges of the capacitor sensor and measuring the amplitudes of these different discharges. The aerosols are accelerated by the accelerator in the direction of the metal layer with such force that they penetrate the metal and damage the oxide layers, thereby allowing the electrical charge on the capacitor to discharge through the damaged region. Each incident aerosol initiates a discharge path through the capacitor in such a fashion as to vaporize the conducting path. Once the discharge action is complete, the low resistance path no longer exists between the two capacitor plates and the capacitor is again able to accept a charge. The active area of the capacitor is reduced in size by the damaged area each time a discharge occurs.
NASA Astrophysics Data System (ADS)
Zhou, Wanhai; Zhu, Ding; Tang, Zhengyao; Wu, Chaoling; Huang, Liwu; Ma, Zhewen; Chen, Yungui
2017-03-01
A series of Al-free Mn-modified AB5-type hydrogen storage alloys have been designed and the effects of thermodynamic stability and electrochemical kinetics on electrochemical performance via Mn substituting have been investigated. Compared with high-Al alloys, the Al-free alloys in this study have better low-temperature performance and instantaneous high-rate output because of the higher surface catalytic ability. After partial substitution of Ni by Mn, both the hydrogen desorption capacity and plateau pressure decrease, and correspondingly results in an improved thermodynamic stability which is adverse to low-temperature delivery. Additionally, with the improvement of charge acceptance ability and anti-corrosion property via Mn substitution, the room-temperature discharge capacity and cycling stability increase slightly. However, Mn adversely affects the electrochemical kinetics and deteriorates both the surface catalytic ability and the bulk hydrogen diffusion ability, leading to the drop of low-temperature dischargeability, high-rate dischargeability and peak power (Ppeak). Based on the thermodynamic and kinetic regulation and overall electrochemical properties, the optimal composition is obtained when x = 0.2, the discharge capacity is 243.6 mAh g-1 at -40 °C with 60 mA g-1, and the Ppeak attains to 969.6 W kg-1 at -40 °C.
Usefulness of ketogenic diet in a girl with migrating partial seizures in infancy.
Mori, Tatsuo; Imai, Katsumi; Oboshi, Taikan; Fujiwara, Yuh; Takeshita, Saoko; Saitsu, Hirotomo; Matsumoto, Naomichi; Takahashi, Yukitoshi; Inoue, Yushi
2016-06-01
Migrating partial seizures in infancy (MPSI) are an age-specific epilepsy syndrome characterized by migrating focal seizures, which are intractable to various antiepileptic drugs and cause severe developmental delay. We report a case of MPSI with heterozygous missense mutation in KCNT1, which was successfully managed by ketogenic diet. At age 2months, the patient developed epilepsy initially manifesting focal seizures with eye deviation and apnea, then evolving to secondarily generalized clonic convulsion. Various antiepileptic drugs including phenytoin, valproic acid, zonisamide, clobazam, levetiracetam, vitamin B6, and carbamazepine were not effective, but high-dose phenobarbital allowed discontinuation of midazolam infusion. Ictal scalp electroencephalogram showed migrating focal seizures. MPSI was suspected and she was transferred to our hospital for further treatment. Potassium bromide (KBr) was partially effective, but the effect was transient. High-dose KBr caused severe adverse effects such as over-sedation and hypercapnia, with no further effects on the seizures. At age 9months, we started a ketogenic diet, which improved seizure frequency and severity without obvious adverse effects, allowing her to be discharged from hospital. Ketogenic diet should be tried in patients with MPSI unresponsive to antiepileptic drugs. In MPSI, the difference in treatment response in patients with and those without KCNT1 mutation remains unknown. Accumulation of case reports would contribute to establish effective treatment options for MPSI. Copyright © 2016 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bilici, Mihai A.; Haase, John R.; Boyle, Calvin R.; Go, David B.; Sankaran, R. Mohan
2016-06-01
We report on the existence of a smooth transition from field emission to a self-sustained plasma in microscale electrode geometries at atmospheric pressure. This behavior, which is not found at macroscopic scales or low pressures, arises from the unique combination of large electric fields that are created in microscale dimensions to produce field-emitted electrons and the high pressures that lead to collisional ionization of the gas. Using a tip-to-plane electrode geometry, currents less than 10 μA are measured at onset voltages of ˜200 V for gaps less than 5 μm, and analysis of the current-voltage (I-V) relationship is found to follow Fowler-Nordheim behavior, confirming field emission. As the applied voltage is increased, gas breakdown occurs smoothly, initially resulting in the formation of a weak, partial-like glow and then a self-sustained glow discharge. Remarkably, this transition is essentially reversible, as no significant hysteresis is observed during forward and reverse voltage sweeps. In contrast, at larger electrode gaps, no field emission current is measured and gas breakdown occurs abruptly at higher voltages of ˜400 V, absent of any smooth transition from the pre-breakdown condition and is characterized only by glow discharge formation.
NASA Astrophysics Data System (ADS)
Krčma, F.; Kozáková, Z.; Mazánková, V.; Horák, J.; Dostál, L.; Obradović, B.; Nikiforov, A.; Belmonte, T.
2018-06-01
A recently presented novel plasma source generating discharge in liquids based on the pin-hole discharge configuration is characterized in detail. The system is supplied by DC non-pulsing high voltage of both polarities in NaCl water solutions at a conductivity range of 100–15 000 μS/cm. The discharge itself shows self-pulsing operation. The discharge ignition is observed in micro bubbles by transient discharge followed by a glow discharge in positive polarity at lower conductivities propagating inside the bubbles. At high conductivities, the glow regime is particularly replaced by a more energetic sequence of transient discharges followed by a shorter glow mode operation. The transient regime probability and its intensity are higher in the negative discharge polarity. The transient discharge produces acoustic waves and shock waves, which are observed at the moment of the bubble cavitation. The average gas temperature of 700–1500 K was calculated from the lowest OH (A-X) 0-0 band transitions. The average electron concentrations of 1020–1023 m‑3 were calculated from H α and H β line profiles. Finally, the production of a chemically active species is determined by hydrogen peroxide energy yields related to the energy consumption of the whole interelectrode system. All these quantities are dependent on the solution conductivity, the discharge polarity, and the applied power.
Motivational stage of change in young patients undergoing day treatment for eating disorders.
Bustin, Lisa A; Lane-Loney, Susan E; Hollenbeak, Christopher S; Ornstein, Rollyn M
2013-01-01
The objective was to determine whether motivation to change is significantly altered over the course of partial hospitalization in children and adolescents with eating disorders (EDs). This study was a retrospective chart review of 30 sets of adolescents and their parents who completed the Motivational Stage of Change for Adolescents Recovering from an Eating Disorder (MSCARED) at both intake and discharge from partial hospitalization. The main outcome variables included change in stage of change (SOC) for patients and their parents. Secondary outcomes included correlations between SOC and other baseline variables, as well as changes in SOC and psychological test scores. The SOC was significantly higher at discharge than at intake in both the patients and parents, but the two groups were not in agreement at discharge. The change in the SOC was correlated with change in Children's Eating Attitudes Test scores. Assessment of decisional balance showed correlations with SOC. Age, change in weight, and psychiatric diagnoses did not correlate with initial SOC. The MSCARED may be a useful tool for monitoring young ED patients' psychological improvements with day treatment. Initial SOC is not predictive of treatment outcomes.
NASA Technical Reports Server (NTRS)
Nordine, Paul C.; Fujimoto, Gordon T.; Greene, Frank T.
1987-01-01
The detection of excited oxygen and ozone molecules formed by surface catalyzed oxygen atom recombination and reaction was investigated by laser induced fluorescence (LIF), molecular beam mass spectrometric (MBMS), and field ionization (FI) techniques. The experiment used partially dissociated oxygen flows from a microwave discharge at pressures in the range from 60 to 400 Pa or from an inductively coupled RF discharge at atmospheric pressure. The catalyst materials investigated were nickel and the reaction cured glass coating used for Space Shuttle reusable surface insulation tiles. Nonradiative loss processes for the laser excited states makes LIF detection of O2 difficult such that formation of excited oxygen molecules could not be detected in the flow from the microwave discharge or in the gaseous products of atom loss on nickel. MBMS experiments showed that ozone was a product of heterogeneous O atom loss on nickel and tile surfaces at low temperatures and that ozone is lost on these materials at elevated temperatures. FI was separately investigated as a method by which excited oxygen molecules may be conveniently detected. Partial O2 dissociation decreases the current produced by FI of the gas.
High Power ECR Ion Thruster Discharge Characterization
NASA Technical Reports Server (NTRS)
Foster, John E.; Kamhawi, Hani; Haag, Thomas; Carpenter, Christian; Williams, George W.
2006-01-01
Electron cyclotron resonance (ECR) based ion thrusters with carbon based ion optics can potentially satisfy lifetime requirements for long duration missions (approximately 10 years) because grid erosion and cathode insert depletion issues are virtually eliminated. Though the ECR plasma discharge has been found to typically operate at slightly higher discharge losses than conventional DC ion thrusters (for high total thruster power applications), the discharge power fraction is small (less than 1 percent at 25 kW). In this regard, the benefits of increased life, low discharge plasma potentials, and reduced complexity are welcome tradeoffs for the associated discharge efficiency decrease. Presented here are results from discharge characterization of a large area ECR plasma source for gridded ion thruster applications. These measurements included load matching efficacy, bulk plasma properties via Langmuir probe, and plasma uniformity as measured using current probes distributed at the exit plane. A high degree of plasma uniformity was observed (flatness greater than 0.9). Additionally, charge state composition was qualitatively evaluated using emission spectroscopy. Plasma induced emission was dominated by xenon ion lines. No doubly charged xenon ions were detected.
Characterization of MoS2-Graphene Composites for High-Performance Coin Cell Supercapacitors.
Bissett, Mark A; Kinloch, Ian A; Dryfe, Robert A W
2015-08-12
Two-dimensional materials, such as graphene and molybdenum disulfide (MoS2), can greatly increase the performance of electrochemical energy storage devices because of the combination of high surface area and electrical conductivity. Here, we have investigated the performance of solution exfoliated MoS2 thin flexible membranes as supercapacitor electrodes in a symmetrical coin cell arrangement using an aqueous electrolyte (Na2SO4). By adding highly conductive graphene to form nanocomposite membranes, it was possible to increase the specific capacitance by reducing the resistivity of the electrode and altering the morphology of the membrane. With continued charge/discharge cycles the performance of the membranes was found to increase significantly (up to 800%), because of partial re-exfoliation of the layered material with continued ion intercalation, as well as increasing the specific capacitance through intercalation pseudocapacitance. These results demonstrate a simple and scalable application of layered 2D materials toward electrochemical energy storage.
Dielectric gas mixtures containing sulfur hexafluoride
Cooke, Chathan M.
1979-01-01
Electrically insulating gaseous media of unexpectedly high dielectric strength comprised of mixtures of two or more dielectric gases are disclosed wherein the dielectric strength of at least one gas in each mixture increases at less than a linear rate with increasing pressure and the mixture gases are present in such proportions that the sum of their electrical discharge voltages at their respective partial pressures exceeds the electrical discharge voltage of each individual gas at the same temperature and pressure as that of the mixture.
Laser-driven acceleration of electrons in a partially ionized plasma channel.
Rowlands-Rees, T P; Kamperidis, C; Kneip, S; Gonsalves, A J; Mangles, S P D; Gallacher, J G; Brunetti, E; Ibbotson, T; Murphy, C D; Foster, P S; Streeter, M J V; Budde, F; Norreys, P A; Jaroszynski, D A; Krushelnick, K; Najmudin, Z; Hooker, S M
2008-03-14
The generation of quasimonoenergetic electron beams, with energies up to 200 MeV, by a laser-plasma accelerator driven in a hydrogen-filled capillary discharge waveguide is investigated. Injection and acceleration of electrons is found to depend sensitively on the delay between the onset of the discharge current and the arrival of the laser pulse. A comparison of spectroscopic and interferometric measurements suggests that injection is assisted by laser ionization of atoms or ions within the channel.
NASA Astrophysics Data System (ADS)
Tschiersch, R.; Nemschokmichal, S.; Bogaczyk, M.; Meichsner, J.
2017-10-01
Single self-stabilized discharge filaments were investigated in the plane-parallel electrode configuration. The barrier discharge was operated inside a gap of 3 mm shielded by glass plates to both electrodes, using helium-nitrogen mixtures and a square-wave feeding voltage at a frequency of 2 kHz. The combined application of electrical measurements, ICCD camera imaging, optical emission spectroscopy and surface charge diagnostics via the electro-optic Pockels effect allowed the correlation of the discharge development in the volume and on the dielectric surfaces. The formation criteria and existence regimes were found by systematic variation of the nitrogen admixture to helium, the total pressure and the feeding voltage amplitude. Single self-stabilized discharge filaments can be operated over a wide parameter range, foremost, by significant reduction of the voltage amplitude after the operation in the microdischarge regime. Here, the outstanding importance of the surface charge memory effect on the long-term stability was pointed out by the recalculated spatio-temporally resolved gap voltage. The optical emission revealed discharge characteristics that are partially reminiscent of both the glow-like barrier discharge and the microdischarge regime, such as a Townsend pre-phase, a fast cathode-directed ionization front during the breakdown and radially propagating surface discharges during the afterglow.
Novel Physical Model for DC Partial Discharge in Polymeric Insulators
NASA Astrophysics Data System (ADS)
Andersen, Allen; Dennison, J. R.
The physics of DC partial discharge (DCPD) continues to pose a challenge to researchers. We present a new physically-motivated model of DCPD in amorphous polymers based on our dual-defect model of dielectric breakdown. The dual-defect model is an extension of standard static mean field theories, such as the Crine model, that describe avalanche breakdown of charge carriers trapped on uniformly distributed defect sites. It assumes the presence of both high-energy chemical defects and low-energy thermally-recoverable physical defects. We present our measurements of breakdown and DCPD for several common polymeric materials in the context of this model. Improved understanding of DCPD and how it relates to eventual dielectric breakdown is critical to the fields of spacecraft charging, high voltage DC power distribution, high density capacitors, and microelectronics. This work was supported by a NASA Space Technology Research Fellowship.
Calibration of ultra-high frequency (UHF) partial discharge sensors using FDTD method
NASA Astrophysics Data System (ADS)
Ishak, Asnor Mazuan; Ishak, Mohd Taufiq
2018-02-01
Ultra-high frequency (UHF) partial discharge sensors are widely used for conditioning monitoring and defect location in insulation system of high voltage equipment. Designing sensors for specific applications often requires an iterative process of manufacturing, testing and mechanical modifications. This paper demonstrates the use of finite-difference time-domain (FDTD) technique as a tool to predict the frequency response of UHF PD sensors. Using this approach, the design process can be simplified and parametric studies can be conducted in order to assess the influence of component dimensions and material properties on the sensor response. The modelling approach is validated using gigahertz transverse electromagnetic (GTEM) calibration system. The use of a transient excitation source is particularly suitable for modeling using FDTD, which is able to simulate the step response output voltage of the sensor from which the frequency response is obtained using the same post-processing applied to the physical measurement.
NASA Astrophysics Data System (ADS)
Dong, Bo; Han, Ming; Wang, Anbo
2012-06-01
A reliable and low-cost two-wavelength quadrature interrogating method has been developed to demodulate optical signals from diaphragm-based Fabry-Perot interferometric fiber optic sensors for multipoint partial discharge detection in power transformers. Commercial available fused-silica parts (a wafer, a fiber ferrule, and a mating sleeve) and a cleaved optical single mode fiber were bonded together to form an extrinsic Fabry-Perot acoustic sensor. Two lasers with center wavelengths separated by a quarter of the period of sensor interference fringes were used to probe acousticwave- induced diaphragm vibration. A coarse wavelength-division multiplexing (CWDM) add/drop multiplexer was used to separate the reflected two wavelengths before two photo detectors. Optical couplers were used to distribute mixed laser light to each sensor-detector module for multiplexing purpose. Sensor structure, detection system design and experiment results are presented.
Two dimensional radial gas flows in atmospheric pressure plasma-enhanced chemical vapor deposition
NASA Astrophysics Data System (ADS)
Kim, Gwihyun; Park, Seran; Shin, Hyunsu; Song, Seungho; Oh, Hoon-Jung; Ko, Dae Hong; Choi, Jung-Il; Baik, Seung Jae
2017-12-01
Atmospheric pressure (AP) operation of plasma-enhanced chemical vapor deposition (PECVD) is one of promising concepts for high quality and low cost processing. Atmospheric plasma discharge requires narrow gap configuration, which causes an inherent feature of AP PECVD. Two dimensional radial gas flows in AP PECVD induces radial variation of mass-transport and that of substrate temperature. The opposite trend of these variations would be the key consideration in the development of uniform deposition process. Another inherent feature of AP PECVD is confined plasma discharge, from which volume power density concept is derived as a key parameter for the control of deposition rate. We investigated deposition rate as a function of volume power density, gas flux, source gas partial pressure, hydrogen partial pressure, plasma source frequency, and substrate temperature; and derived a design guideline of deposition tool and process development in terms of deposition rate and uniformity.
Water resources data, Ohio, water year 2003 : Volume 1. Ohio River basin excluding project data
Shindel, H.L.; Mangus, J.P.; Frum, S.R.
2004-01-01
Water-resources data for the 2003 water year for Ohio consist of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground-water wells. This report, in two volumes, contains records for water discharge at 138 gaging stations and various partial-record sites; water levels at 217 observation wells and 35 crest-stage gages; and water quality at 30 gaging stations, 34 observation wells, and no partial-record sites. Also included are data from miscellaneous and synoptic sites. Additional water data were collected at various sites not involved in the systematic data-collection program and are published as miscellaneous measurements and analyses. These data represent that part of the National Water Information System collected by the U.S. Geological Survey and cooperating Federal, State, and local agencies in Ohio.
Shindel, H.L.; Mangus, J.P.; Frum, S.R.
2004-01-01
Water-resources data for the 2003 water year for Ohio consist of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground-water wells. This report, in two volumes, contains records for water discharge at 138 gaging stations and various partial-record sites; water levels at 217 observation wells and 35 crest-stage gages; and water quality at 30 gaging stations, 34 observation wells, and no partial-record sites. Also included are data from miscellaneous and synoptic sites. Additional water data were collected at various sites not involved in the systematic data-collection program and are published as miscellaneous measurements and analyses. These data represent that part of the National Water Information System collected by the U.S. Geological Survey and cooperating Federal, State, and local agencies in Ohio.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rockwell, G.L.; Hayes, P.D.; Agajanian, J.
1997-07-01
Water-resources data for the 1996 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 149 gaging stations and 6 crest-stage partial-record stations, stage and contents for 21 lakes and reservoirs, gage height records for 1 station, water quality for 19 streamflow-gaging stations and 17 partial-record stations, and precipitation data for 4 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State andmore » Federal agencies in California.« less
Bigger, Harold R.; Fogg, Louis J.; Patel, Aloka; Johnson, Tricia; Engstrom, Janet L.; Meier, Paula P.
2014-01-01
Objective The objective of this study was to compare the currently used human milk (HM) quality indicators that measure whether very low birthweight (VLBW; <1500 g birthweight) infants “ever” received HM and whether they were still receiving HM at discharge from the neonatal intensive care unit (NICU) to the actual amount and timing of HM received. Study Design This study used data from a large NIH-funded cohort study and calculated whether VLBW infants ever received HM (HM-Ever) and of these infants, the percentage who were still receiving HM at NICU discharge (HM-DC). Then, the HM-DC indicator (exclusive, partial and none) was compared with the amount and timing of HM feedings received by these same infants. Results Of the 291 VLBW infants who met inclusion criteria, 285 received some HM (HM-Ever = 98%). At NICU discharge (HM-DC), 24.2%, 15.1% and 60.7% were receiving exclusive, partial and no HM, respectively. Of the 60.7% infants with no HM-DC, some had received higher amounts of HM during the NICU hospitalization than infants categorized as exclusive and partial for HM-DC. Of the infants with no HM-DC, 76.8% and 59.7% had received exclusive HM during the Days 1–14 and Days 1–28 exposure periods, respectively. Conclusion The average daily dose (HM-DD; in mL/kg/d) and cumulative percentage (HM-PCT; as % of cumulative enteral intake) of HM feedings were sufficient to significantly reduce the risk of multiple morbidities, including late onset sepsis, necrotizing enterocolitis, neurocognitive delay and rehospitalization, in the majority of the VLBW infants who were discharged with no HM-DC. Quality indicators that focus on the amount and timing of HM feedings in the NICU should be added to the HM-Ever and HM-DC measures. PMID:24526005
Plasma polymerization of ethylene in an atmospheric pressure-pulsed discharge
NASA Technical Reports Server (NTRS)
Donohoe, K.; Wydeven, T.
1979-01-01
The polymerization of ethylene in an atmospheric pressure-pulsed discharge has been studied. Partial pressures of ethylene up to 4 kN/sq m were used with helium as a diluent. Deposition rates (on glass slides) were the same throughout the discharge volume over a wide range of operating conditions. These rates were in the 1-2 A/sec range. The films were clear, soft, and showed good adhesion to the glass substrates. Oligomers large enough to visibly scatter 637.8-nm light were observed in the gas phase under all conditions in which film deposition occurred. The experimental results suggest that Brownian diffusion of these oligomers was the rate-limiting step in the film deposition process.
NASA Technical Reports Server (NTRS)
Hong, S. H.; Wilhelm, H. E.
1978-01-01
An electrical discharge between two ring electrodes embedded in the mantle of a cylindrical chamber is considered, in which the plasma in the anode and cathode regions rotates in opposite directions under the influence of an external axial magnetic field. The associated boundary-value problem for the coupled partial differential equations describing the azimuthal velocity and radial current-density fields is solved in closed form. The velocity, current density, induced magnetic induction, and electric fields are presented for typical Hartmann numbers, magnetic Reynolds numbers, and geometry parameters. The discharge is shown to produce anodic and cathodic plasma sections rotating at speeds of the order 1,000,000 cm/sec for conventional magnetic field intensities. Possible application of the magnetoactive discharge as a plasma centrifuge for isotope separation is discussed.
Albert, Ryan J; McLaughlin, Christine; Falatko, Debra
2014-10-15
Fish hold effluent and the effluent produced from the cleaning of fish holds may contain organic material resulting from the degradation of seafood and cleaning products (e.g., soaps and detergents). This effluent is often discharged by vessels into near shore waters and, therefore, could have the potential to contribute to water pollution in bays and estuaries. We characterized effluent from commercial fishing vessels with holds containing refrigerated seawater, ice slurry, or chipped ice. Concentrations of trace heavy metals, wet chemistry parameters, and nutrients in effluent were compared to screening benchmarks to determine if there is a reasonable potential for effluent discharge to contribute to nonattainment of water quality standards. Most analytes (67%) exceeded their benchmark concentration and, therefore, may have the potential to pose risk to human health or the environment if discharges are in significant quantities or there are many vessels discharging in the same areas. Published by Elsevier Ltd.
Lithium battery discharge tests
NASA Technical Reports Server (NTRS)
Johnson, C. J.
1980-01-01
The long term discharge of a variety of lithium cells was characterized and the susceptibility of the cells to chemical variation during the slow discharge was tested. A shunt resistor was set across the terminals to monitor the voltage as a function of time. Failures were identified by premature voltage drops.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fields, M.K.; Davis, R.P.
1992-08-01
A wastewater characterization survey was conducted by members of the Armstrong Laboratory Occupational and Environmental Health directorate Water Quality Function from 28 Oct 91 - 7 Nov 91 at Whiteman AFB, MO. The purpose of the survey was to identify and characterize the wastewater, determine the appropriateness of present disposal methods, determine the need for routine sampling or monitoring and recommend parameters for wastewater analysis. Results of the sampling showed metals and volatile organic discharge in varying concentrations throughout the base. Recommendations are: (1) evaluation of industrial operations and chemical disposal procedures at designated sites; (2) routine monitoring of themore » discharge from the Hospital and Audiovisual for silver; (3) excavation and sediment disposal at the Transportation Washrack and WWTP Effluent discharge point; (4) collection and analyses of sludge at oil water separators, to include the oil and water side; (5) evaluation of the sanitary sewer system for corrosion and sediment buildup by a mobile Reveal and Seal Unit; (6) background soil sample collection and analyses; and (7) pretreatment of Aqueous Film Forming Foam discharge and notification of the Base Bioenvironmental Engineer, Environmental Coordinator, and WWTP personnel when discharge occurs.« less
NASA Astrophysics Data System (ADS)
Yunxiao, ZHANG; Yuanxiang, ZHOU; Ling, ZHANG; Zhen, LIN; Jie, LIU; Zhongliu, ZHOU
2018-05-01
In this paper, work was conducted to reveal electrical tree behaviors (initiation and propagation) of silicone rubber (SIR) under an impulse voltage with high temperature. Impulse frequencies ranging from 10 Hz to 1 kHz were applied and the temperature was controlled between 30 °C and 90 °C. Experimental results show that tree initiation voltage decreases with increasing pulse frequency, and the descending amplitude is different in different frequency bands. As the pulse frequency increases, more frequent partial discharges occur in the channel, increasing the tree growth rate and the final shape intensity. As for temperature, the initiation voltage decreases and the tree shape becomes denser as the temperature gets higher. Based on differential scanning calorimetry results, we believe that partial segment relaxation of SIR at high temperature leads to a decrease in the initiation voltage. However, the tree growth rate decreases with increasing temperature. Carbonization deposition in the channel under high temperature was observed under microscope and proven by Raman analysis. Different tree growth models considering tree channel characteristics are proposed. It is believed that increasing the conductivity in the tree channel restrains the partial discharge, holding back the tree growth at high temperature.
NASA Astrophysics Data System (ADS)
Chang, Chien-Chieh; Chen, Chia-Shyun
2003-02-01
An analytical approach using integral transform techniques is developed to deal with a well hydraulics model involving a mixed boundary of a flowing partially penetrating well, where constant drawdown is stipulated along the well screen and no-flux condition along the remaining unscreened part. The aquifer is confined of finite thickness. First, the mixed boundary is changed into a homogeneous Neumann boundary by discretizing the well screen into a finite number of segments, each of which at constant drawdown is subject to unknown a priori well bore flux. Then, the Laplace and the finite Fourier transforms are used to solve this modified model. Finally, the prescribed constant drawdown condition is reinstated to uniquely determine the well bore flux function, and to restore the relation between the solution and the original model. The transient and the steady-state solutions for infinite aquifer thickness can be derived from the semi-analytical solution, complementing the currently available dual integral solution. If the distance from the edge of the well screen to the bottom/top of the aquifer is 100 times greater than the well screen length, aquifer thickness can be assumed infinite for times of practical significance, and groundwater flow can reach a steady-state condition, where the well will continuously supply water under a constant discharge. However, if aquifer thickness is smaller, the well discharge decreases with time. The partial penetration effect is most pronounced in the vicinity of the flowing well, decreases with increasing horizontal distance, and vanishes at distances larger than 1-2 times the aquifer thickness divided by the square root of aquifer anisotropy. The horizontal hydraulic conductivity and the specific storage coefficient can be determined from vertically averaged drawdown as measured by fully penetrating observation wells. The vertical hydraulic conductivity can be determined from the well discharge under two particular partial penetration conditions.
Plasma processes in water under effect of short duration pulse discharges
NASA Astrophysics Data System (ADS)
Gurbanov, Elchin
2013-09-01
It is very important to get a clear water without any impurities and bacteria by methods, that don't change the physical and chemical indicators of water now. In this article the plasma processes during the water treatment by strong electric fields and short duration pulse discharges are considered. The crown discharge around an electrode with a small radius of curvature consists of plasma leader channels with a high conductivity, where the thermo ionization processes and UV-radiation are taken place. Simultaneously the partial discharges around potential electrode lead to formation of atomic oxygen and ozone. The spark discharge arises, when plasma leader channels cross the all interelectrode gap, where the temperature and pressure are strongly grown. As a result the shock waves and dispersing liquid streams in all discharge gap are formed. The plasma channels extend, pressure inside it becomes less than hydrostatic one and the collapse and UV-radiation processes are started. The considered physical processes can be successfully used as a basis for development of pilot-industrial installations for conditioning of drinking water and to disinfecting of sewage.
19 CFR 18.6 - Short shipments; shortages; entry and allowance.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., in the case of a partial shortage. (d) If merchandise covered by a carnet cannot be recovered intact... and birds found by the discharging officer to be dead on arrival at destination, shall be made in the...
19 CFR 18.6 - Short shipments; shortages; entry and allowance.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., in the case of a partial shortage. (d) If merchandise covered by a carnet cannot be recovered intact... and birds found by the discharging officer to be dead on arrival at destination, shall be made in the...
Giuli, Gabriele; Eisenmann, Tobias; Bresser, Dominic; Trapananti, Angela; Asenbauer, Jakob; Mueller, Franziska; Passerini, Stefano
2017-12-29
In order to further improve the energy and power density of state-of-the-art lithium-ion batteries (LIBs), new cell chemistries and, therefore, new active materials with alternative storage mechanisms are needed. Herein, we report on the structural and electrochemical characterization of Fe-doped ZnO samples with varying dopant concentrations, potentially serving as anode for LIBs (Rechargeable lithium-ion batteries). The wurtzite structure of the Zn 1-x Fe x O samples (with x ranging from 0 to 0.12) has been refined via the Rietveld method. Cell parameters change only slightly with the Fe content, whereas the crystallinity is strongly affected, presumably due to the presence of defects induced by the Fe 3+ substitution for Zn 2+ . XANES (X-ray absorption near edge structure) data recorded ex situ for Zn 0.9 Fe 0.1 O electrodes at different states of charge indicated that Fe, dominantly trivalent in the pristine anode, partially reduces to Fe 2+ upon discharge. This finding was supported by a detailed galvanostatic and potentiodynamic investigation of Zn 1-x Fe x O-based electrodes, confirming such an initial reduction of Fe 3+ to Fe 2+ at potentials higher than 1.2 V (vs. Li⁺/Li) upon the initial lithiation, i.e., discharge. Both structural and electrochemical data strongly suggest the presence of cationic vacancies at the tetrahedral sites, induced by the presence of Fe 3+ (i.e., one cationic vacancy for every two Fe 3+ present in the sample), allowing for the initial Li⁺ insertion into the ZnO lattice prior to the subsequent conversion and alloying reaction.
Plasma rotation by electric and magnetic fields in a discharge cylinder
NASA Technical Reports Server (NTRS)
Wilhelm, H. E.; Hong, S. H.
1977-01-01
A theoretical model for an electric discharge consisting of a spatially diverging plasma sustained electrically between a small ring cathode and a larger ring anode in a cylindrical chamber with an axial magnetic field is developed to study the rotation of the discharge plasma in the crossed electric and magnetic fields. The associated boundary-value problem for the coupled partial differential equations which describe the electric potential and the plasma velocity fields is solved in closed form. The electric field, current density, and velocity distributions are discussed in terms of the Hartmann number and the Hall coefficient. As a result of Lorentz forces, the plasma rotates with speeds as high as 1 million cm/sec around its axis of symmetry at typical conditions. As an application, it is noted that rotating discharges of this type could be used to develop a high-density plasma-ultracentrifuge driven by j x B forces, in which the lighter (heavier) ion and atom components would be enriched in (off) the center of the discharge cylinder.
Engel, Kirsten G; Buckley, Barbara A; Forth, Victoria E; McCarthy, Danielle M; Ellison, Emily P; Schmidt, Michael J; Adams, James G
2012-09-01
Many patients are discharged from the emergency department (ED) with an incomplete understanding of the information needed to safely care for themselves at home. Patients have demonstrated particular difficulty in understanding post-ED care instructions (including medications, home care, and follow-up). The objective of this study was to further characterize these deficits and identify gaps in knowledge that may place the patient at risk for complications or poor outcomes. This was a prospective cohort, phone interview-based study of 159 adult English-speaking patients within 24 to 36 hours of ED discharge. Patient knowledge was assessed for five diagnoses (ankle sprain, back pain, head injury, kidney stone, and laceration) across the following five domains: diagnosis, medications, home care, follow-up, and return instructions. Knowledge was determined based on the concordance between direct patient recall and diagnosis-specific discharge instructions combined with chart review. Two authors scored each case independently and discussed discrepancies before providing a final score for each domain (no, minimal, partial, or complete comprehension). Descriptive statistics were used for the analyses. The study population was 50% female with a median age of 41 years (interquartile range [IQR] = 29 to 53 years). Knowledge deficits were demonstrated by the majority of patients in the domain of home care instructions (80%) and return instructions (79%). Less frequent deficits were found for the domains of follow-up (39%), medications (22%), and diagnosis (14%). Minimal or no understanding in at least one domain was demonstrated by greater than two-thirds of patients and was found in 40% of cases for home care and 51% for return instructions. These deficits occurred less frequently for domains of follow-up (18%), diagnosis (3%), and medications (3%). Patients demonstrate the most frequent knowledge deficits for home care and return instructions, raising significant concerns for adherence and outcomes. © 2012 by the Society for Academic Emergency Medicine.
NASA Astrophysics Data System (ADS)
Vagin, N. P.; Ionin, A. A.; Kochetov, I. V.; Napartovich, A. P.; Sinitsyn, D. V.; Yuryshev, N. N.
2017-03-01
The existing kinetic model describing self-sustained and electroionization discharges in mixtures enriched with singlet oxygen has been modified to calculate the characteristics of a flow RF discharge in molecular oxygen and its mixtures with helium. The simulations were performed in the gas plug-flow approximation, i.e., the evolution of the plasma components during their motion along the channel was represented as their evolution in time. The calculations were carried out for the O2: He = 1: 0, 1: 1, 1: 2, and 1: 3 mixtures at an oxygen partial pressure of 7.5 Torr. It is shown that, under these conditions, volumetric gas heating in a discharge in pure molecular oxygen prevails over gas cooling via heat conduction even at an electrode temperature as low as 100 K. When molecular oxygen is diluted with helium, the behavior of the gas temperature changes substantially: heat removal begins to prevail over volumetric gas heating, and the gas temperature at the outlet of the discharge zone drops to 220-230 K at room gas temperature at the inlet, which is very important in the context of achieving the generation threshold in an electric-discharge oxygen-iodine laser based on a slab cryogenic RF discharge.
Wilberg, D.E.; Stolp, B.J.
1985-01-01
Hydrologic, geologic, and partial water quality data were collected at 90 selected springs in west-central Utah, and chemical analyses performed on water samples from 62 of the springs. Descriptions of the physiographic and geologic conditions, climate, and vegetation patterns for the study area are included. Allowable limits of certain chemical constituents in water for human and livestock consumption are included with the water quality data. Three classifications of springs were established based on physical characteristics of the springs, and chemical composition of the springflow: (1) mountain springs; (2) non-thermal valley springs, and (3) thermal valley springs. Mountain springs are in and near recharge areas, have seasonal variations of discharge and temperature, typically discharge from extrusive and metamorphic geohydrologic units, and generally discharge freshwater. Non-thermal valley springs are peripheral to recharge areas, have seasonal variations of discharge and temperature, typically discharge from a variety of geohydrologic units, and have variable water composition. Thermal valley springs are near topographic low areas of valleys , and have little seasonal variation of discharge or temperature. They typically discharge from unconsolidated deposits (but the discharge probably has flowed through buried carbonate geohydrologic units). They also have a considerable range of water composition that reflects the relative complexity of the groundwater system. (Author 's abstract)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durlin, R.R.; Schaffstall, W.P.
1996-03-01
Volume 2 contains: (1) discharge records for 94 continuous-record streamflow-gaging stations and 39 partial-record stations; (2) elevation and contents records for 12 lakes and reservoirs; (3) water-quality records for 17 gaging stations and 125 partial-record and project stations; and (4) water-level records for 25 observation wells. Additional water data collected at various sites not involved in the systematic data-collection program are also presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agajanian, J.A.; Rockwell, G.L.; Hayes, P.D.
1996-04-01
Volume 1 contains (1) discharge records for 141 streamflow-gaging stations, 6 crest-stage partial-record streamflow stations; (2) stage and contents records for 20 lakes and reservoirs; (3) water quality records for 21 streamflow-gaging stations and 3 partial-record stations; and (4) precipitation records for 1 station.
Characterization of a dielectric barrier discharge in controlled atmosphere
NASA Astrophysics Data System (ADS)
Kogelheide, Friederike; Offerhaus, Björn; Bibinov, Nikita; Bracht, Vera; Smith, Ryan; Lackmann, Jan-Wilm; Awakowicz, Peter; Stapelmann, Katharina; Bimap Team; Aept Team
2016-09-01
Non-thermal atmospheric-pressure plasmas are advantageous for various biomedical applications as they make a contact- and painless therapy possible. Due to the potential medical relevance of such plasma sources further understanding of the chemical and physical impact on biological tissue regarding the efficacy and health-promoting effect is necessary. The knowledge of properties and effects offers the possibility to configure plasmas free of risk for humans. Therefore, tailoring the discharge chemistry in regard to resulting oxidative and nitrosative effects on biological tissue by adjusting different parameters is of growing interest. In order to ensure stable conditions for the characterization of the discharge, the used dielectric barrier discharge was mounted in a vessel. Absolutely calibrated optical emission spectroscopy was carried out to analyze the electron density and the reduced electric field. The rather oxygen-based discharge was tuned towards a more nitrogen-based discharge by adjusting several parameters as reactive nitrogen species are known to promote wound healing. Furthermore, the impact of an ozone-free discharge has to be studied. This work was funded by the German Research Foundation (DFG) with the packet grant PAK 816 `Plasma Cell Interaction in Dermatology'.
Characterization of microwave discharge plasmas for surface processing
NASA Astrophysics Data System (ADS)
Nikolic, Milka
We have developed several diagnostic techniques to characterize two types of microwave (MW) discharge plasmas: a supersonic flowing argon MW discharge maintained in a cylindrical quartz cavity at frequency ƒ = 2.45 GHz and a pulse repetitive MW discharge in air at ƒ = 9.5 GHz. Low temperature MW discharges have been proven to posses attractive properties for plasma cleaning and etching of niobium surfaces of superconductive radio frequency (SRF) cavities. Plasma based surface modification technologies offer a promising alternative for etching and cleaning of SRF cavities. These technologies are low cost, environmentally friendly and easily controllable, and present a possible alternative to currently used acid based wet technologies, such as buffered chemical polishing (BCP), or electrochemical polishing (EP). In fact, weakly ionized. non-equilibrium, and low temperature gas discharges represent a powerful tool for surface processing due to the strong chemical reactivity of plasma radicals. Therefore, characterizing these discharges by applying non-perturbing, in situ measurement techniques is of vital importance. Optical emission spectroscopy has been employed to analyze the molecular structure and evaluate rotational and vibrational temperatures in these discharges. The internal plasma structure was studied by applying a tomographic numerical method based on the two-dimensional Radon formula. An automated optical measurement system has been developed for reconstruction of local plasma parameters. It was found that excited argon states are concentrated near the tube walls, thus confirming the assumption that the post discharge plasma is dominantly sustained by a travelling surface wave. Employing a laser induced fluorescence technique in combination with the time synchronization device allowed us to obtain time-resolved population densities of some excited atomic levels in argon. We have developed a technique for absolute measurements of electron density based on the time-resolved absolute intensity of a Nitrogen spectral band belonging to the Second Positive System, the kinetic model and the detailed particle balance of the N2 (C 3piu) state. Measured electron density waveforms are in fair agreement with electron densities obtained using the Stark broadening technique. In addition, time dependent population densities of Ar I metastable and resonant levels were obtained by employing a kinetic model developed based on analysis of population density rates of excited Ar I p levels. Both the experimental results and numerical models for both types of gas discharges indicate that multispecies chemistry of gases plays an important role in understanding the dynamics and characterizing the properties of these discharges.
Wall Conditioning Characterization in NSTX-U
NASA Astrophysics Data System (ADS)
Caron, D.; Soukhanovskii, V.; Scotti, F.; Weller, M.
2016-10-01
Impurities in tokamak plasmas can lead to disruptive instabilities due to radiative energy loss which impede access to high-confinements mode. One source of impurities in NSTX-U are water molecules trapped in graphite plasma facing components (PFCs), which make up the walls and divertors. Hydrogen and oxygen impurities are released into the plasma due to plasma surface interactions. Extreme ultraviolet (EUV) and visible spectrometers are used in conjunction with a residual gas analyzer (RGA) to characterize the source and amount of released impurities. A high resolution visible spectrometer measured H/D Balmer- α intensity ratio on the inner wall, the upper and lower divertors, and provided a hydrogen time history for shot-to-shot trends. The RGA provided partial pressure trends of masses 2 (H2) , 16 (O2) , and 18 (H2O). Trends of O VIII and C VI spectral line intensities from the core plasma were obtained from the EUV spectrometer. The trends are correlated with wall conditioning, namely helium glow discharge cleaning and boronization. Using these trends, impurity content monitoring and recommendations for wall conditioning can be implemented. Work supported by DOE under Contracts DE-AC52-07NA27344 and DE-AC02-09CH11466.
NASA Technical Reports Server (NTRS)
Lee, S. S.; Sengupta, S.; Nwadike, E. V.
1980-01-01
A user's manual for a one dimensional thermal model to predict the temperature profiles of a deep body of water for any number of annual cycles is presented. The model is essentially a set of partial differential equations which are solved by finite difference methods using a high speed digital computer. The model features the effects of area change with depth, nonlinear interaction of wind generated turbulence and buoyancy, adsorption of radiative heat flux below the surface, thermal discharges, and the effects of vertical convection caused by discharge. The main assumption in the formulation is horizontal homogeneity. The environmental impact of thermal discharges from power plants is emphasized. Although the model is applicable to most lakes, a specific site (Lake Keowee, S.C.) application is described in detail. The programs are written in FORTRAN 5.
Inert gas ion thruster development
NASA Technical Reports Server (NTRS)
Ramsey, W. D.
1980-01-01
Two 12 cm magneto-electrostatic containment (MESC) ion thrusters were performance mapped with argon and xenon. The first, hexagonal, thruster produced optimized performance of 48.5to 79 percent argon mass utilization efficiencies at discharge energies of 240 to 425 eV/ion, respectively, Xenon mass utilization efficiencies of 78 to 95 percent were observed at discharge energies of 220 to 290 eV/ion with the same optimized hexagonal thruster. Changes to the cathode baffle reduced the discharge anode potential during xenon operation from approximately 40 volts to about 30 volts. Preliminary tests conducted with the second, hemispherical, MESC thruster showed a nonuniform anode magnetic field adversely affected thruster performance. This performance degradation was partially overcome by changes in the boundary anode placement. Conclusions drawn the hemispherical thruster tests gave insights into the plasma processes in the MESC discharge that will aid in the design of future thrusters.
Water Resources Data, West Virginia, Water Year 2003
Ward, S.M.; Rosier, M.T.; Crosby, G.R.
2004-01-01
Water-resources data for the 2003 water year for West Virginia consists of records of stream discharge, reservoir and ground-water levels, and water quality of streams and ground-water wells. This report contains discharge records for 70 streamflow-gaging stations; discharge records provided by adjacent states for 8 streamflow-gaging stations; annual maximum discharge at 16 crest-stage partial-record stations; stage records for 6 detention reservoirs; water-quality records for 2 stations; and water-level records for 8 observation wells. Locations of streamflow, detention reservoir, and water-quality stations are shown on figure 4. Locations of ground-water observation wells are shown on figure 5. Additional water data were collected at various sites, not involved in the systematic data-collection program, and are published as miscellaneous sites. These data represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in West Virginia.
Water resources data-West Virginia, water year 2004
Ward, S.M.; Rosier, M.T.; Crosby, G.R.
2005-01-01
Water-resources data for the 2004 water year for West Virginia consist of records of stream discharge, reservoir and ground-water levels, and water quality of streams and ground-water wells. This report contains discharge records for 65 streamflow-gaging stations; discharge records provided by adjacent states for 8 streamflow-gaging stations; annual maximum discharge at 17 crest-stage partial-record stations; stage records for 14 detention reservoirs; water-quality records for 2 stations; and water-level records for 10 observation wells. Locations of streamflow, detention reservoir, and water-quality stations are shown on figure 4. Locations of ground-water observation wells are shown on figure 5. Additional water-quality data were collected at various sites, not involved in the systematic data collection program, and are published as miscellaneous sites. These data represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in West Virginia.
NASA Astrophysics Data System (ADS)
Richardson, M. J.; Zuck, N.; Gardner, W. D.
2016-02-01
Flow from the Mississippi-Atchafalaya River System generally peaks during the spring freshet, discharging nutrient-rich fresh water and sediment into the northern Gulf of Mexico. The peak discharge varies year to year as a result of varying drought or flood conditions in the Mississippi watershed. When compared to an 8-year climatological average, summer 2012 is characterized by low discharge into the northern Gulf of Mexico, whereas summer 2013 is characterized by average discharge conditions. Water samples were collected during four cruises during June and August of 2012 and 2013 to assess the changes in concentration and composition of bulk particulate matter. While no consistent relationship between particulate matter composition and hypoxia was observed, there are several statistically significant seasonal and inter-annual changes in the concentration and composition of particulate matter associated with varying river discharge. There is also evidence that some sub-pycnocline turbidity and chlorophyll-a may be due to in situ primary productivity, rather than settled plankton containing chlorophyll-a.
Astray, G; Soto, B; Lopez, D; Iglesias, M A; Mejuto, J C
2016-01-01
Transit data analysis and artificial neural networks (ANNs) have proven to be a useful tool for characterizing and modelling non-linear hydrological processes. In this paper, these methods have been used to characterize and to predict the discharge of Lor River (North Western Spain), 1, 2 and 3 days ahead. Transit data analyses show a coefficient of correlation of 0.53 for a lag between precipitation and discharge of 1 day. On the other hand, temperature and discharge has a negative coefficient of correlation (-0.43) for a delay of 19 days. The ANNs developed provide a good result for the validation period, with R(2) between 0.92 and 0.80. Furthermore, these prediction models have been tested with discharge data from a period 16 years later. Results of this testing period also show a good correlation, with R(2) between 0.91 and 0.64. Overall, results indicate that ANNs are a good tool to predict river discharge with a small number of input variables.
The hydrogen isotope ratio in W7-AS during deuterium NBI heating
NASA Astrophysics Data System (ADS)
Zebisch, P.; Taglauer, E.; W7-AS Team; NBI Team
1999-04-01
With a so-called sniffer probe the fraction of hydrogen during discharges with deuterium NBI heating was studied in the plasma edge of the stellarator W7-AS. As expected, the ratios were significantly lower than in discharges with hydrogen NBI heating but were higher than those in discharges with only ECRH. An examination of the possible reasons for this increase concludes that it is not only partially caused by the direct influence of neutral injection but also depends on the energy content of the plasma determined by the heating power and the confinement time. Of course, the isotope ratio also depends on the starting conditions, i.e. the isotope ratio before the onset of NBI.
Detrecting and Locating Partial Discharges in Transformers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shourbaji, A.; Richards, R.; Kisner, R. A.
A collaborative research between the Oak Ridge National Laboratory (ORNL), the American Electric Power (AEP), the Tennessee Valley Authority (TVA), and the State of Ohio Energy Office (OEO) has been formed to conduct a feasibility study to detect and locate partial discharges (PDs) inside large transformers. The success of early detection of the PDs is necessary to avoid costly catastrophic failures that can occur if the process of PD is ignored. The detection method under this research is based on an innovative technology developed by ORNL researchers using optical methods to sense the acoustical energy produced by the PDs. ORNLmore » researchers conducted experimental studies to detect PD using an optical fiber as an acoustic sensor capable of detecting acoustical disturbances at any point along its length. This technical approach also has the potential to locate the point at which the PD was sensed within the transformer. Several optical approaches were experimentally investigated, including interferometric detection of acoustical disturbances along the sensing fiber, light detection and ranging (LIDAR) techniques using frequency modulation continuous wave (FMCW), frequency modulated (FM) laser with a multimode fiber, FM laser with a single mode fiber, and amplitude modulated (AM) laser with a multimode fiber. The implementation of the optical fiber-based acoustic measurement technique would include installing a fiber inside a transformer allowing real-time detection of PDs and determining their locations. The fibers are nonconductive and very small (core plus cladding are diameters of 125 μm for single-mode fibers and 230 μm for multimode fibers). The research identified the capabilities and limitations of using optical technology to detect and locate sources of acoustical disturbances such as in PDs in large transformers. Amplitude modulation techniques showed the most promising results and deserve further research to better quantify the technique’s sensitivity and its ability to characterize a PD event. Other sensing techniques have been also identified, such as the wavelength shifting fiber optics and custom fabricated fibers with special coatings.« less
A lithium oxygen secondary battery
NASA Technical Reports Server (NTRS)
Semkow, Krystyna W.; Sammells, Anthony F.
1987-01-01
Some recent work on a lithium-oxygen secondary battery is reported in which stabilized zirconia oxygen vacancy conducting solid electrolytes were used for the effective separation of respective half-cell reactions. The electroactive material consisted of alloys possessing the general composition Li(x)FeSi2 immersed in a ternary molten salt comprising LiF, LiCl, and Li2O. The manufacture of the cell is described, and discharge-current voltage curves for partially charged cells are shown and discussed. A galvanostatic IR free-changing curve and an IR-free charge-discharge curve are also shown.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Yim, John; Herman, Daniel; Williams, George; Gilland, James; Peterson, Peter; Hofer, Richard; Mikellides, Ioannis
2016-01-01
NASAs Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) Hall thruster has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front pole cover thruster configuration with the thruster body electrically tied to cathode and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68 and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability was mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 110-5 Torr-Xe (for thruster flow rate above 8 mgs). Power spectral density analysis of the discharge current waveform showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant frequency. Finally the IVB maps of the TDU-1 thruster taken at elevated magnetic fields indicated that the discharge current became more oscillatory with increased facility background pressure at lower thruster mass flow rates, where thruster operation at higher flow rates resulted in less change to the thrusters IVB characteristics.
Zn/gelled 6 M KOH/O 2 zinc-air battery
NASA Astrophysics Data System (ADS)
Mohamad, A. A.
The gel electrolyte for the zinc-air cell was prepared by mixing hydroponics gel with a 6 M potassium hydroxide aqueous solution. The self-discharge of cells was characterized by measuring the open-circuit voltage. The effect of a discharge rate of 50 mA constant current on cell voltage and plateau hour, as well as the voltage-current and current density-power density were measured and analysed. The electrode degradation after discharge cycling was characterized by structural and surface methods. The oxidation of the electrode surface further blocked the utilization of the Zn anode and was identified as a cause for the failure of the cell.
Ocean outfall plume characterization using an Autonomous Underwater Vehicle.
Rogowski, Peter; Terrill, Eric; Otero, Mark; Hazard, Lisa; Middleton, William
2013-01-01
A monitoring mission to map and characterize the Point Loma Ocean Outfall (PLOO) wastewater plume using an Autonomous Underwater Vehicle (AUV) was performed on 3 March 2011. The mobility of an AUV provides a significant advantage in surveying discharge plumes over traditional cast-based methods, and when combined with optical and oceanographic sensors, provides a capability for both detecting plumes and assessing their mixing in the near and far-fields. Unique to this study is the measurement of Colored Dissolved Organic Matter (CDOM) in the discharge plume and its application for quantitative estimates of the plume's dilution. AUV mission planning methodologies for discharge plume sampling, plume characterization using onboard optical sensors, and comparison of observational data to model results are presented. The results suggest that even under variable oceanic conditions, properly planned missions for AUVs equipped with an optical CDOM sensor in addition to traditional oceanographic sensors, can accurately characterize and track ocean outfall plumes at higher resolutions than cast-based techniques.
Alternative hospital gift bags and breastfeeding exclusivity.
Bai, Yeon; Wunderlich, Shahla M; Kashdan, Rickie
2013-01-01
The type of gift bags given to new mothers at the time of discharge from the hospital can influence their confidence in breastfeeding. Most hospitals in the US continue to distribute commercial gift bags containing formula samples despite the reported negative influence of commercial bags on the duration of breastfeeding. This study compared breastfeeding outcomes in women receiving three different kinds of gift bags at discharge. A prospective intervention study was conducted during 2009-2010 in New Jersey. Three breastfeeding cohorts were recruited and assigned to three groups: COMMERCIAL received discharge bags containing formula samples, BF-INFO received breastfeeding information and supplies, and PUMP received breastfeeding information/supplies plus a manual breast pump. Follow-up contacts were at 2, 4, and 12 postpartum weeks to determine breastfeeding outcome. The mean durations of exclusive (EBF) and partial breastfeeding were compared between groups using ANOVA. A total of 386 participants completed the study. The mean EBF duration (weeks) in the PUMP (n = 138, 8.28 ± 4.86) and BF-INFO (n = 121, 7.87 ± 4.63) were significantly longer (P < 0.01) than COMMERCIAL (n = 127, 6.12 ± 4.49). The rate of EBF through 12 weeks in PUMP was most consistent. The mean duration of partial breastfeeding showed similar results: significantly longer in PUMP and BF-INFO than COMMERCIAL (P < 0.01).
NASA Astrophysics Data System (ADS)
Steves, Simon; Styrnoll, Tim; Mitschker, Felix; Bienholz, Stefan; Nikita, Bibinov; Awakowicz, Peter
2013-11-01
Optical emission spectroscopy (OES) and multipole resonance probe (MRP) are adopted to characterize low-pressure microwave (MW) and radio frequency (RF) discharges in oxygen. In this context, both discharges are usually applied for the deposition of permeation barrier SiOx films on plastic foils or the inner surface of plastic bottles. For technological reasons the MW excitation is modulated and a continuous wave (cw) RF bias is used. The RF voltage produces a stationary low-density plasma, whereas the high-density MW discharge is pulsed. For the optimization of deposition process and the quality of the deposited barrier films, plasma conditions are characterized using OES and MRP. To simplify the comparison of applied diagnostics, both MW and RF discharges are studied separately in cw mode. The OES and MRP diagnostic methods complement each other and provide reliable information about electron density and electron temperature. In the MW case, electron density amounts to ne = (1.25 ± 0.26) × 1017 m-3, and kTe to 1.93 ± 0.20 eV, in the RF case ne = (6.8 ± 1.8)×1015 m-3 and kTe = 2.6 ± 0.35 eV. The corresponding gas temperatures are 760±40 K and 440±20 K.
Chopper-controlled discharge life cycling studies on lead-acid batteries
NASA Technical Reports Server (NTRS)
Kraml, J. J.; Ames, E. P.
1982-01-01
State-of-the-art 6 volt lead-acid golf car batteries were tested. A daily charge/discharge cycling to failure points under various chopper controlled pulsed dc and continuous current load conditions was undertaken. The cycle life and failure modes were investigated for depth of discharge, average current chopper frequency, and chopper duty cycle. It is shown that battery life is primarily and inversely related to depth of discharge and discharge current. Failure mode is characterized by a gradual capacity loss with consistent evidence of cell element aging.
Dynamic characteristics of electric discharge in liquid under ultrasonic cavitation
NASA Astrophysics Data System (ADS)
Bulychev, N. A.; Kazaryan, M. A.; Averyushkin, A. S.; Kirichenko, M. N.; Zakharyan, Robert; Chernov, A. A.
2018-04-01
The characteristics of electrical discharges in liquid media under the influence of intense ultrasonic vibrations are investigated and the difference in dynamic characteristics of discharges before cavitation and after cavitation begins. The experiments carried out during this work made it possible to establish that in a liquid in an intense ultrasonic field above the cavitation threshold there exists a special form of an electric discharge characterized by volumetric luminescence in the entire space between the electrodes and the current-voltage characteristic inherent in an anomalous glow discharge in a gas.
Wang, Guizhi; Jing, Wenping; Wang, Shuling; Xu, Yi; Wang, Zhangyong; Zhang, Zhouling; Li, Quanlong; Dai, Minhan
2014-11-18
We identified a barely noticed contributor, submarine groundwater discharge (SGD), to acidification of a coastal fringing reef system in Sanya Bay in the South China Sea based on time-series observations of Ra isotopes and carbonate system parameters. This coastal system was characterized by strong diel changes throughout the spring to neap tidal cycle of dissolved inorganic carbon (DIC), total alkalinity, partial pressure of CO2 (pCO2) and pH, in the ranges of 1851-2131 μmol kg(-1), 2182-2271 μmol kg(-1), 290-888 μatm and 7.72-8.15, respectively. Interestingly, the diurnal amplitudes of these parameters decreased from spring to neap tides, governed by both tidal pumping and biological activities. In ebb stages during the spring tide, we observed the lowest salinities along with the highest DIC, pCO2 and Ra isotopes, and the lowest pH and aragonite saturation state. These observations were consistent with a concurrent SGD rate up to 25 and 44 cm d(-1), quantified using Darcy's law and (226)Ra, during the spring tide ebb, but negligible at flood tides. Such tidal-driven SGD of low pH waters is another significant contributor to coastal acidification, posing additional stress on coastal coral systems, which would be even more susceptible in future scenarios under higher atmospheric CO2.
Motor correlates of models of secondary bilateral synchrony and multiple epileptic foci.
Jiruska, Premysl; Proks, Jan; Otáhal, Jakub; Mares, Pavel
2007-10-01
Bilateral synchronous epileptiform discharges registered in patients with partial epilepsies may be generated by different pathophysiological mechanisms. Differentiation between underlying mechanisms is often crucial for correct diagnosis and adequate treatment in clinical epileptology. The aim of this study was to model in rats two possible mechanisms--secondary bilateral sychrony and interaction between multiple epilepic foci. Furthermore, to describe in detail semiology, laterality and differences in motor phenomena. Secondary bilateral synchrony was modeled by unilateral topical application of bicuculline methiodide (BMI) over the sensorimotor cortex. Bilateral symmetric application of BMI was used as a model of multiple epileptic foci. Electrographic and behavioural phenomena were recorded for 1h following the application of BMI. Electroencephalogram in both groups was characterized by presence of bilateral synchronous discharges. Myoclonic and clonic seizures involving forelimb and head muscles represented the most common motor seizure pattern in both groups. Significant differences were found in the laterality of motor phenomena. Motor seizures in unilateral foci always started in the contralateral limbs whereas symmetrical foci exhibited bilateral independent onset of convulsions. Similar lateralization was observed in interictal motor phenomena (myoclonic jerks). An important influence of posture on epileptic motor phenomena was demonstrated. Active or passive changes in animal posture (verticalization to bipedal posture) caused conversion from unilateral myoclonic jerks or clonic seizures to bilaterally synchronous (generalized) motor phenomena in both groups.
NASA Technical Reports Server (NTRS)
Abraham, K. M.; Elliot, J. E.
1984-01-01
NiS2 and NiS have been characterized as high energy density rechargeable positive electrodes for moderate-temperature Na batteries of the configuration, Na(1)/beta double prime-Al2O3/NaAlCl4(1), NiSx. The batteries operate in the temperature range 170 - 190 C. Positive electrode reactions during discharge/charge cycles have been characterized. Excellent rechargeability of the batteries has been demonstrated by extended cell cycling. A Na/NiS2 cell, operating at 190 C, exceeded 600 deep discharge/charge cycles with practically no capacity deterioration. The feasibility of secondary Na/NiSx batteries with specific energies equal to or greater than 50 Wh/lb and cycle lifes exceeding 1000 deep discharge/charge cycles has been demonstrated.
Plasma in a Pulsed Discharge Environment
NASA Technical Reports Server (NTRS)
Remy, J.; Bienier, L.; Salama, F.
2005-01-01
The plasma generated in a pulsed slit discharge nozzle is used to form molecular ions in an astrophysically relevant environment. The plasma has been characterized as a glow discharge in the abnormal regime. Laboratory studies help understand the formation processes of polycyclic aromatic hydrocarbon (PAH) ions that are thought to be the source of the ubiquitous unidentified infrared bands.
Matthieu, D.E.; Carroll, K.C.; Mainhagu, J.; Morrison, C.; McMillan, A.; Russo, A.; Plaschke, M.
2013-01-01
The objective of this study was to characterize the temporal behavior of contaminant mass discharge, and the relationship between reductions in contaminant mass discharge and reductions in contaminant mass, for a very heterogeneous, highly contaminated source-zone field site. Trichloroethene is the primary contaminant of concern, and several lines of evidence indicate the presence of organic liquid in the subsurface. The site is undergoing groundwater extraction for source control, and contaminant mass discharge has been monitored since system startup. The results show a significant reduction in contaminant mass discharge with time, decreasing from approximately 1 to 0.15 kg/d. Two methods were used to estimate the mass of contaminant present in the source area at the initiation of the remediation project. One was based on a comparison of two sets of core data, collected 3.5 years apart, which suggests that a significant (~80%) reduction in aggregate sediment-phase TCE concentrations occurred between sampling events. The second method was based on fitting the temporal contaminant mass discharge data with a simple exponential source-depletion function. Relatively similar estimates, 784 and 993 kg, respectively, were obtained with the two methods. These data were used to characterize the relationship between reductions in contaminant mass discharge (CMDR) and reductions in contaminant mass (MR). The observed curvilinear relationship exhibits a reduction in contaminant mass discharge essentially immediately upon initiation of mass reduction. This behavior is consistent with a system wherein significant quantities of mass are present in hydraulically poorly accessible domains for which mass removal is influenced by rate-limited mass transfer. The results obtained from the present study are compared to those obtained from other field studies to evaluate the impact of system properties and conditions on mass-discharge and mass-removal behavior. The results indicated that factors such as domain scale, hydraulic-gradient status (induced or natural), and flushing-solution composition had insignificant impact on the CMDR-MR profiles and thus on underlying mass-removal behavior. Conversely, source-zone age, through its impact on contaminant distribution and accessibility, was implicated as a critical factor influencing the nature of the CMDR-MR relationship. PMID:23528743
Electrolyte effects in a model of proton discharge on charged electrodes
NASA Astrophysics Data System (ADS)
Wiebe, Johannes; Kravchenko, Kateryna; Spohr, Eckhard
2015-01-01
We report results on the influence of NaCl electrolyte dissolved in water on proton discharge reactions from aqueous solution to charged platinum electrodes. We have extended a recently developed combined proton transfer/proton discharge model on the basis of empirical valence bond theory to include NaCl solutions with several different concentrations of cations and anions, both stoichiometric (1:1) compositions and non-stoichiometric ones with an excess of cations. The latter solutions partially screen the electrostatic potential from the surface charge of the negatively charged electrode. 500-1000 trajectories of a discharging proton were integrated by molecular dynamics simulations until discharge occurred, or for at most 1.5 ns. The results show a strong dependence on ionic strength, but only a weak dependence on the screening behavior, when comparing stoichiometric and non-stoichiometric solutions. Overall, the Na+ cations exert a more dominant effect on the discharge reaction, which we argue is likely due to the very rigid arrangements of the cations on the negatively polarized electrode surface. Thus, our model predicts, for the given and very high negative surface charge densities, the fastest discharge reaction for pure water, but obviously cannot take into account the fact that such high charge densities are even more out of reach experimentally than for higher electrolyte concentrations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Jiao; Wang Yanhui; Wang Dezhen
2013-04-15
The pulsed discharge for producing iodine atoms from the alkyl and perfluoroalky iodides (CH{sub 3}I, CF{sub 3}I, etc.) is the most efficient method for achieving the pulse operating mode of a chemical oxygen-iodine laser. In this paper, a one-dimensional fluid model is developed to study the characteristics of pulsed discharge in CF{sub 3}I-He mixture. By solving continuity equation, momentum equation, Poisson equation, Boltzmann equation, and an electric circuit equation, the temporal evolution of discharge current density and various discharge products, especially the atomic iodine, are investigated. The dependence of iodine atom density on discharge parameters is also studied. The resultsmore » show that iodine atom density increases with the pulsed width and pulsed voltage amplitude. The mixture ratio of CF{sub 3}I and helium plays a more significant role in iodine atom production. For a constant voltage amplitude, there exists an optimal mixture ratio under which the maximum iodine atom concentration is achieved. The bigger the applied voltage amplitude is, the higher partial pressure of CF{sub 3}I is needed to obtain the maximum iodine atom concentration.« less
NASA Astrophysics Data System (ADS)
Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.
2018-03-01
Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.
Curran, Janet A; Bishop, Andrea; Plint, Amy; MacPhee, Shannon; Zemek, Roger; Chorney, Jill; Jabbour, Mona; Porter, Stephen; Sawyer, Scott
2017-04-17
One of the most important transitions in the continuum of care for children is discharge to home. Optimal discharge communication between healthcare providers and caregivers (e.g., parents or other guardians) who present to the emergency department (ED) with their children is not well understood. The lack of policies and considerable variation in practice regarding discharge communication in pediatric EDs pose a quality and safety risk for children and their parents. The aim of this mixed methods study is to better understand the process and structure of discharge communication in a pediatric ED context to contribute to the design and development of discharge communication interventions. We will use surveys, administrative data and real-time video observation to characterize discharge communication for six common illness presentations in a pediatric ED: (1) asthma, (2) bronchiolitis, (3) abdominal pain, (4) fever, (5) diarrhea and vomiting, and (6) minor head injury. Participants will be recruited from one of two urban pediatric EDs in Canada. Video recordings will be analyzed using Observer XT. We will use logistic regression to identify potential demographic and visit characteristic cofounders and multivariate logistic regression to examine association between verbal and non-verbal behaviours and parent recall and comprehension. Video recording of discharge communication will provide an opportunity to capture important data such as temporality, sequence and non-verbal behaviours that might influence the communication process. Given the importance of better characterizing discharge communication to identify potential barriers and enablers, we anticipate that the findings from this study will contribute to the development of more effective discharge communication policies and interventions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vagin, N. P.; Ionin, A. A., E-mail: aion@sci.lebedev.ru; Kochetov, I. V.
The existing kinetic model describing self-sustained and electroionization discharges in mixtures enriched with singlet oxygen has been modified to calculate the characteristics of a flow RF discharge in molecular oxygen and its mixtures with helium. The simulations were performed in the gas plug-flow approximation, i.e., the evolution of the plasma components during their motion along the channel was represented as their evolution in time. The calculations were carried out for the O{sub 2}: He = 1: 0, 1: 1, 1: 2, and 1: 3 mixtures at an oxygen partial pressure of 7.5 Torr. It is shown that, under these conditions,more » volumetric gas heating in a discharge in pure molecular oxygen prevails over gas cooling via heat conduction even at an electrode temperature as low as ~100 K. When molecular oxygen is diluted with helium, the behavior of the gas temperature changes substantially: heat removal begins to prevail over volumetric gas heating, and the gas temperature at the outlet of the discharge zone drops to ~220–230 K at room gas temperature at the inlet, which is very important in the context of achieving the generation threshold in an electric-discharge oxygen−iodine laser based on a slab cryogenic RF discharge.« less
Nationwide survey of partial fundoplication in Korea: comparison with total fundoplication.
Lee, Chang Min; Park, Joong-Min; Lee, Han Hong; Jun, Kyong Hwa; Kim, Sungsoo; Seo, Kyung Won; Park, Sungsoo; Kim, Jong-Han; Kim, Jin-Jo; Han, Sang-Uk
2018-06-01
Laparoscopic total fundoplication is the standard surgery for gastroesophageal reflux disease. However, partial fundoplication may be a viable alternative. Here, we conducted a nationwide survey of partial fundoplication in Korea. The Korean Anti-Reflux Surgery study group recorded 32 cases of partial fundoplication at eight hospitals between September 2009 and January 2016. The surgical outcomes and postoperative adverse symptoms in these cases were evaluated and compared with 86 cases of total fundoplication. Anterior partial fundoplication was performed in 20 cases (62.5%) and posterior in 12 (37.5%). In most cases, partial fundoplication was a secondary procedure after operations for other conditions. Half of patients who underwent partial fundoplication had typical symptoms at the time of initial diagnosis, and most of them showed excellent (68.8%), good (25.0%), or fair (6.3%) symptom resolution at discharge. Compared to total fundoplication, partial fundoplication showed no difference in the resolution rate of typical and atypical symptoms. However, adverse symptoms such as dysphagia, difficult belching, gas bloating and flatulence were less common after partial fundoplication. Although antireflux surgery is not popular in Korea and total fundoplication is the primary surgical choice for gastroesophageal reflux disease, partial fundoplication may be useful in certain conditions because it has less postoperative adverse symptoms but similar efficacy to total fundoplication.
Characterization of the Electron Energy Distribution Function in a Penning Discharge
NASA Astrophysics Data System (ADS)
Skoutnev, Valentin; Dourbal, Paul; Raitses, Yevgeny
2017-10-01
Slow and fast sweeping Langmuir probe diagnostics were implemented to measure the electron energy distribution function (EEDF) in a cross-field Penning discharge undergoing rotating spoke phenomenon. The EEDF was measured using the Druyvesteyn method. Rotating spoke occurs in a variety of ExB devices and is characterized primarily by azimuthal light, density, and potential fluctuations on the order of a few kHz, but is theoretically still not well understood. Characterization of a time-resolved EEDF of the spoke would be important for understanding physical mechanisms responsible for the spoke and its effects on Penning discharges, Hall thrusters, sputtering magnetrons, and other ExB devices. In this work, preliminary results of measurements of the EEDF using slow and fast Langmuir probes that sweep below and above the fundamental spoke frequency will be discussed. This work was supported by the Air Force Office of Scientific Research (AFOSR).
NASA Astrophysics Data System (ADS)
Nemschokmichal, Sebastian; Tschiersch, Robert; Meichsner, Jürgen
2017-11-01
The laser photodetachment experiment in a diffuse helium-oxygen barrier discharge is evaluated by a 1D fluid simulation. As in the experiment, the simulated discharge operates in helium with 400 {ppm} oxygen admixture at 500 {mbar} inside a discharge gap of 3 {mm}. The laser photodetachment is included by the interaction of negative ions with a temporally and spatially dependent photon flux. The simulation with the usually applied set of reactions and rate coefficients provides a much lower negative ion density than needed to explain the impact on the discharge characteristics in the experiment. Further processes for an enhanced negative ion formation and their capabilities of reproducing the experimental results are discussed. These further processes are additional attachment processes in the volume and the negative ion formation at the negatively charged dielectric. Both approaches are able to reproduce the measured laser photodetachment effect partially, but the best agreement with the experimental results is achieved with the formation of negative ions at the negatively charged dielectric.
Characterization system for research on energy storage capacitors.
Noriega, J R; Iyore, O D; Budime, C; Gnade, B; Vasselli, J
2013-05-01
In this work a characterization system for high energy-density capacitors is described and demonstrated. Capacitors are being designed using thin-film technology in an attempt to achieve higher energy-density levels by operating the devices at a high voltage. These devices are fabricated from layers of 100 nm aluminum and a layer of polyvinylidene fluoride-hexafluoropropylene on a polyethylene naphthalate plastic substrate. The devices have been designed to store electrical charge at up to 200 V. Characterizations of these devices focus on the measurement of capacitance vs bias voltage and temperature, equivalent series resistance, and charge/discharge cycles. For the purpose of the characterization of these capacitors, an electronic charge/discharge interface was designed and tested.
NASA Astrophysics Data System (ADS)
Malinina, A. A.; Malinin, A. N.
2016-09-01
The results of studies of spectral, temporal, and energy characteristics of radiation in a gas discharge plasma based on a mixture of mercury diiodide vapor with helium and nitrogen in the spectral range of 350-800 nm are presented. Plasma was produced by a barrier discharge in a device with a cylindrical aperture. The electrodes 0.2 m in length were placed at a distance of 0.015 m. The amplitude of the pump pulses, their duration, and frequency were equal to 20-30 kV, 150 ns, and 1-20 kHz, respectively. Radiation of mercury monoiodide exciplex molecules was revealed in the visible spectra region. Dependences of the plasma optical characteristics on the partial pressures of the mixture components were established.
Water resources data, Kansas, water year 2004
Putnam, J.E.; Schneider, D.R.
2005-01-01
Water-resources data for the 2004 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 155 complete-record gaging stations; elevation and contents at 17 lakes and reservoirs; water-quality records at 2 precipitation stations, water-level data at 14 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 16 gaging stations and 2 lakes with water-quality monitors. Also included are discharge data for 29 high-flow partial-record stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.
Redox reactions with empirical potentials: atomistic battery discharge simulations.
Dapp, Wolf B; Müser, Martin H
2013-08-14
Batteries are pivotal components in overcoming some of today's greatest technological challenges. Yet to date there is no self-consistent atomistic description of a complete battery. We take first steps toward modeling of a battery as a whole microscopically. Our focus lies on phenomena occurring at the electrode-electrolyte interface which are not easily studied with other methods. We use the redox split-charge equilibration (redoxSQE) method that assigns a discrete ionization state to each atom. Along with exchanging partial charges across bonds, atoms can swap integer charges. With redoxSQE we study the discharge behavior of a nano-battery, and demonstrate that this reproduces the generic properties of a macroscopic battery qualitatively. Examples are the dependence of the battery's capacity on temperature and discharge rate, as well as performance degradation upon recharge.
NASA Technical Reports Server (NTRS)
Jorns, Benjamin A.; Goebel, Dan M.; Hofer, Richard R.
2015-01-01
An experimental investigation is presented to quantify the effect of high-speed probing on the plasma parameters inside the discharge chamber of a 6-kW Hall thruster. Understanding the nature of these perturbations is of significant interest given the importance of accurate plasma measurements for characterizing thruster operation. An array of diagnostics including a high-speed camera and embedded wall probes is employed to examine in real time the changes in electron temperature and plasma potential induced by inserting a high-speed reciprocating Langmuir probe into the discharge chamber. It is found that the perturbations onset when the scanning probe is downstream of the electron temperature peak, and that along channel centerline, the perturbations are best characterized as a downstream shift of plasma parameters by 15-20% the length of the discharge chamber. A parametric study is performed to investigate techniques to mitigate the observed probe perturbations including varying probe speed, probe location, and operating conditions. It is found that the perturbations largely disappear when the thruster is operated at low power and low discharge voltage. The results of this mitigation study are discussed in the context of recommended methods for generating unperturbed measurements of the discharge chamber plasma.
Application of surface electrical discharges to the study of lightning strikes on aircraft
NASA Technical Reports Server (NTRS)
Boulay, J. L.; Larigaldie, S.
1991-01-01
Considered here is the characterization of surface discharges which provide a facility complementary to that of artificially triggered lightning. General characteristics of a simplified surface discharge, including current waveforms and the constitution of a surface discharge are outlined, and the application of this approach to the study of aircraft lightning strikes is considered. Representations of leader-streamer and return-stroke phases are discussed, and the application to the two-dimensional discharge phase is covered. It is noted that the fact that the initiation times of surface discharges could be controlled, and the path followed by the discharge channels could be predetermined, indicates that it is possible to produce a highly dedicated high performance instrumentation system.
NASA Astrophysics Data System (ADS)
Hussain, S.; Qazi, H. I. A.; Badar, M. A.
2014-03-01
An experimental investigation to characterize the properties and highlight the benefits of atmospheric pressure radio-frequency dielectric-barrier discharge (rf DBD) with dielectric electrodes fabricated by anodizing aluminium substrate is presented. The current-voltage characteristics and millisecond images are used to distinguish the α and γ modes. This atmospheric rf DBD is observed to retain the discharge volume without constriction in γ mode. Optical emission spectroscopy demonstrates that the large discharge current leads to more abundant reactive species in this plasma source.
Modeling and characterization of supercapacitors for wireless sensor network applications
NASA Astrophysics Data System (ADS)
Zhang, Ying; Yang, Hengzhao
A simple circuit model is developed to describe supercapacitor behavior, which uses two resistor-capacitor branches with different time constants to characterize the charging and redistribution processes, and a variable leakage resistance to characterize the self-discharge process. The parameter values of a supercapacitor can be determined by a charging-redistribution experiment and a self-discharge experiment. The modeling and characterization procedures are illustrated using a 22F supercapacitor. The accuracy of the model is compared with that of other models often used in power electronics applications. The results show that the proposed model has better accuracy in characterizing the self-discharge process while maintaining similar performance as other models during charging and redistribution processes. Additionally, the proposed model is evaluated in a simplified energy storage system for self-powered wireless sensors. The model performance is compared with that of a commonly used energy recursive equation (ERE) model. The results demonstrate that the proposed model can predict the evolution profile of voltage across the supercapacitor more accurately than the ERE model, and therefore provides a better alternative for supporting research on storage system design and power management for wireless sensor networks.
Muscle hypertrophy with complex repetitive discharges in C-6 radiculopathy.
Rousseff, Rossen T; Tzvetanov, Plamen
2005-08-01
To report on a case of post-denervation muscle hypertrophy in an unusual distribution. A 52-year-old patient with severe flaccid paraparesis after polio developed unilateral C-6 radiculopathy that resolved with conservative treatment. Within 2 years marked hypertrophy, stiffness and pain in the muscles in the affected myotome developed. EMG discovered abundant complex repetitive discharges (CRD) within hypertrophic muscles. On biopsy, true hypertrophy of muscle fibers and some group atrophy was found. Steroid treatment relieved the symptoms and significantly suppressed the CRD. The possible causative role of CRD for hypertrophy in partially denervated muscle is discussed.
Drain placement can be safely omitted after the majority of robotic partial nephrectomies.
Abaza, Ronney; Prall, David
2013-03-01
Drain placement after partial nephrectomy is considered standard but it is based on routine and not on evidence. With experience we performed robotic partial nephrectomy and routinely omitted a drain even with significant collecting system violation. We have rarely used drains after robotic partial nephrectomy for several years, and we report our outcomes. We reviewed a single surgeon, prospective database of all robotic partial nephrectomies from February 2008 to March 2012, including the characteristics of those with and without a drain. The 150 patients underwent a total of 160 robotic partial nephrectomy procedures with a drain used in 11 patients and omitted in 93%. Mean patient age was 57 years (range 22 to 89), mean American Society of Anesthesiologists score was 2.8 (range 2 to 4) and mean body mass index was 32 kg/m(2) (range 18 to 54). Values were similar in patients with and without a drain. In patients without a drain and in those with a drain mean tumor size was 3.5 cm (range 1.0 to 11.0) and 4.6 cm (range 1.1 to 8.6), and mean R.E.N.A.L. (radius, exophytic/endophytic, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines, hilar tumor touching main renal artery or vein) nephrometry score was 7.8 (range 4 to 12) and 8.8 (range 6 to 11), respectively. Collecting system violation occurred in 88 patients (59%), including 78 without a drain. Two patients (1.3%) required transfusion with no intervention for bleeding. All except 5 patients (97%) were discharged home on postoperative day 1 with all drains removed before discharge. In 2 patients (1.3%) without a drain small urinomas without infection developed more than 2 weeks postoperatively, which were treated with a week of Foley catheter drainage and percutaneous drainage, respectively. Drain placement after robotic partial nephrectomy can be routinely omitted with a low rate of urine leaks, which can be managed safely when they rarely occur. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Ashpis, David E.; Laun, Matthew C.
2016-01-01
We present results of thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators. We have used a test setup, measurement, and data processing methodology that we developed in prior work. The tests were conducted with High Density Polyethylene (HDPE) actuators of three thicknesses. The applied voltage driving the actuators was a pure sinusoidal waveform. The test setup was suspended actuators with a partial liquid interface. The tests were conducted at low ambient humidity. The thrust was measured with an analytical balance and the results were corrected for anti-thrust to isolate the plasma generated thrust. Applying this approach resulted in smooth and repeatable data. It also enabled curve fitting that yielded quadratic relations between the plasma thrust and voltage in log-log space at constant frequencies. The results contrast power law relationships developed in literature that appear to be a rough approximation over a limited voltage range.
NASA Astrophysics Data System (ADS)
Zhao, Hongyang; Cai, Kang; Ma, Zhibin; Cheng, Zhenxiang; Jia, Tingting; Kimura, Hideo; Fu, Qiuming; Tao, Hong; Xiong, Liwei
2018-02-01
A method to synthesize molybdenum carbides has been developed based on microwave plasma treatment with methane and hydrogen mixed gases, using a microwave-plasma chemical vapor deposition device. The device framework and its mechanism are described in detail. Two-dimensional α-Mo2C has been directly synthesized by a plate-to-plate substrate holder structure with a microwave power of 920 W and a partial pressure of 20 kPa. In-situ optical emission spectroscopy was used to measure the radical types in the plasma ball during glow discharge. The as-grown α-Mo2C samples were characterized by X-ray diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy and Raman spectroscopy to determine their phases, purity and chemical groups. The superconducting transition temperature was measured, and the transition temperatures of the relevant phases are discussed in detail. The results confirmed that this method is an efficient way to obtain molybdenum carbides and inspire new research interest in transition metal carbides, which have many intrinsic local properties and applications.
Congenital Lobar Emphysema: An Approach of Anesthetic Management.
Mourya, Meenakshi; Meena, Dharam Singh
2016-08-01
Congenital Lobar Emphysema (CLE) is a medical condition which is quiet rarely seen especially in neonates. The disease is characterized by over inflation of lungs which is produced due to inhibition of escape of inspired air from lungs. This condition usually occurs in infants due to partial obstruction of the bronchus and can be reversed with timely and planned anaesthetic management. Here in, we are presenting a case of an infant who was merely four months of age. CLE was affecting his left upper lobe since birth which was being treated as lobar pneumonia outside at some peripheral health center. The case presented to hospital with the symptoms acute respiratory distress and was taken up for urgent surgical management. Left upper lobectomy was performed which relived his symptoms. Case was discharged from hospital after 10 days of uneventful hospital stay. The case was challenging, as it involved careful and planned anaesthetic management of lung separation as well as prevention of hyperventilation of the un-involved lung.
Chemically grafted carbon-coated LiFePO4 using diazonium chemistry
NASA Astrophysics Data System (ADS)
Delaporte, Nicolas; Perea, Alexis; Amin, Ruhul; Zaghib, Karim; Bélanger, Daniel
2015-04-01
The effect of surface functionalization of aminophenyl and bromophenyl groups on carbon-coated LiFePO4 and the electrochemical properties of composite electrode containing these materials are reported. The functionalization was performed by spontaneous reduction of the corresponding in situ generated diazonium ions. The resulting chemically grafted LiFePO4/C materials were characterized by energy-dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS) to confirm the presence of the surface organic species. XRD analyses indicated the cathode material was partially oxidized. Thermogravimetric and elemental analyses revealed the loading of grafted molecules was between 0.2 and 1.1 wt.% depending on the reaction conditions. Interestingly, the electrochemical performances of the modified LiFePO4/C are not adversely affected by the presence of either aminophenyl and bromophenyl groups at the carbon surface, and in fact the grafted LiFePO4/C displayed slightly superior discharge capacity at the highest C rate investigated for a low loading of organic molecules.
Carbon microgranule injection into NSTX-U discharges for edge diagnostic research
NASA Astrophysics Data System (ADS)
Lunsford, Robert; Roquemore, A. Lane; Scotti, Filippo; Mansfield, Dennis; Bortolon, Alessandro; Kaita, Robert; Maingi, Rajesh
2016-10-01
Microgranule injection is a versatile means for investigating edge plasmas in fusion devices. Employing a dual bladed rotary turbine, carbon microgranules ranging in diameter from 300 - 700 microns are radially injected into NSTX-U discharges at approximately 50 m/sec. Utilizing multiple high speed camera views, a 3D reconstruction of the injection geometry is created which characterizes the ablation rate and granule trajectory. By coupling this with a neutral gas shielding (NGS) ablation model, the granule mass deposition profile can be determined. Simulation projects a depositional barycenter near the pedestal shoulder for H-mode discharges, and 20 cm inboard of the LCFS for L-mode discharges. Spectroscopic measurements of this localized particle source can be used to characterize impurity transport within the discharge, and potentially allows for direct measurement of the safety factor profile (q). In addition, the transient pressure peaking resultant from injection into H-mode plasmas can also result in the prompt triggering of an edge localized mode (ELM). Work supported by DOE Contract No. DE-AC02-09CH11466.
Laufs, Helmut; Hamandi, Khalid; Salek-Haddadi, Afraim; Kleinschmidt, Andreas K; Duncan, John S; Lemieux, Louis
2007-01-01
A cerebral network comprising precuneus, medial frontal, and temporoparietal cortices is less active both during goal-directed behavior and states of reduced consciousness than during conscious rest. We tested the hypothesis that the interictal epileptic discharges affect activity in these brain regions in patients with temporal lobe epilepsy who have complex partial seizures. At the group level, using electroencephalography-correlated functional magnetic resonance imaging in 19 consecutive patients with focal epilepsy, we found common decreases of resting state activity in 9 patients with temporal lobe epilepsy (TLE) but not in 10 patients with extra-TLE. We infer that the functional consequences of TLE interictal epileptic discharges are different from those in extra-TLE and affect ongoing brain function. Activity increases were detected in the ipsilateral hippocampus in patients with TLE, and in subthalamic, bilateral superior temporal and medial frontal brain regions in patients with extra-TLE, possibly indicating effects of different interictal epileptic discharge propagation. PMID:17133385
Jang, Cheng-Shin
2015-05-01
Accurately classifying the spatial features of the water temperatures and discharge rates of hot springs is crucial for environmental resources use and management. This study spatially characterized classifications of the water temperatures and discharge rates of hot springs in the Tatun Volcanic Region of Northern Taiwan by using indicator kriging (IK). The water temperatures and discharge rates of the springs were first assigned to high, moderate, and low categories according to the two thresholds of the proposed spring classification criteria. IK was then used to model the occurrence probabilities of the water temperatures and discharge rates of the springs and probabilistically determine their categories. Finally, nine combinations were acquired from the probability-based classifications for the spatial features of the water temperatures and discharge rates of the springs. Moreover, various combinations of spring water features were examined according to seven subzones of spring use in the study region. The research results reveal that probability-based classifications using IK provide practicable insights related to propagating the uncertainty of classifications according to the spatial features of the water temperatures and discharge rates of the springs. The springs in the Beitou (BT), Xingyi Road (XYR), Zhongshanlou (ZSL), and Lengshuikeng (LSK) subzones are suitable for supplying tourism hotels with a sufficient quantity of spring water because they have high or moderate discharge rates. Furthermore, natural hot springs in riverbeds and valleys should be developed in the Dingbeitou (DBT), ZSL, Xiayoukeng (XYK), and Macao (MC) subzones because of low discharge rates and low or moderate water temperatures.
Del Galdo, Sara; Amadei, Andrea
2016-10-12
In this paper we apply the computational analysis recently proposed by our group to characterize the solvation properties of a native protein in aqueous solution, and to four model aqueous solutions of globular proteins in their unfolded states thus characterizing the protein unfolded state hydration shell and quantitatively evaluating the protein unfolded state partial molar volumes. Moreover, by using both the native and unfolded protein partial molar volumes, we obtain the corresponding variations (unfolding partial molar volumes) to be compared with the available experimental estimates. We also reconstruct the temperature and pressure dependence of the unfolding partial molar volume of Myoglobin dissecting the structural and hydration effects involved in the process.
NASA Astrophysics Data System (ADS)
Abarca, Elena; Karam, Hanan; Hemond, Harold F.; Harvey, Charles F.
2013-05-01
Detailed field measurements are combined with a numerical modeling to characterize the groundwater dynamics beneath the discharge zone at Waquoit Bay, Massachusetts. Groundwater salinity values revealed a saline circulation cell that overlaid the discharging freshwater and grew and disappeared with the lunar cycle. The cell was initiated by a greater bay water infiltration during the new moon when high tides overtopped the mean high-tide mark, flooding the flatter beach berm and inundating a larger area of the beach. The dynamics of this cell were further characterized by a tracer test and by constructing a density-dependent flow model constrained to salinity and head data. The numerical model captured the growing and diminishing behavior of the circulation cell and provided the estimates of freshwater and saline water fluxes and travel times. Furthermore, the model enabled quantification of the relationship between the characteristics of the observed tidal cycle (maximum, minimum, and mean tidal elevations) and the different components of the groundwater circulation (freshwater discharge, intertidal saline cycling, and deep saline cycling). We found that (1) recharge to the intertidal saline cell is largely controlled by the high-tide elevation; (2) freshwater discharge is positively correlated to the low-tide elevation, whereas deep saline discharge from below the discharging freshwater is negatively correlated to the low-tide elevation. So, when the low-tide elevation is relatively high, more freshwater discharges and less deep saltwater discharges. In contrast when low tides are very low, less freshwater discharges and more deep salt water discharges; (3) offshore inflow of saline water is largely insensitive to tides and the lunar cycle.
Dermal Sensitization of 1-Acetyloctahydro-3,5,7-Trinitro-1,3,5,7-Tetrazocine.
1984-08-08
raw data for this study were audited on 29 May 84. Routine inspections with no adverse findings are reported quarterly, thus these inspections are...SEX. Its discharge, while partially mitigated by present and planned polution abatement facilities at HSAAP, will continue and could increase at
The Taunton River is a partially mixed tidal estuary in southeastern Massachusetts (USA) which has received significant contaminant inputs, yet little information exists on the history of discharge and the subsequent fate of these contaminants. Three sediment cores taken along a...
Code of Federal Regulations, 2014 CFR
2014-10-01
...: Community Mental Health Centers (CMHCs) § 485.918 Condition of participation: Organization, governance... individuals, individuals with serious mental illness, and residents of its mental health service area who have been discharged from an inpatient mental health facility. (a) Standard: Governing body and...
Analytical solutions describing the time-dependent DNAPL source-zone mass and contaminant discharge rate are used as a flux-boundary condition in a semi-analytical contaminant transport model. These analytical solutions assume a power relationship between the flow-averaged sourc...
Index of surface-water stations in Texas, January 1986
Carrillo, E.R.; Buckner, H.D.; Rawson, Jack
1986-01-01
As of January 1, 1986, the surface-water data-collection network in Texas operated by the U.S. Geological Survey included 386 streamflow, 87 reservoir-contents, 33 stage, 10 crest-stage partial-record, 8 periodic discharge through range, 38 flood-hydrograph partial-record, 11 flood-profile partial-record , 36 low-flow partial-record 2 tide-level, 45 daily chemical-quality, 23 continuous-recording water-quality, 97 periodic biological, 19 lake surveys, 174 periodic organic- and (or) nutrient, 4 periodic insecticide, 58 periodic pesticide, 22 automatic sampler, 157 periodic minor elements, 141 periodic chemical-quality, 108 periodic physical-organic, 14 continuous-recording three- or four-parameter water-quality, 3 sediment, 39 periodic sediment, 26 continuous-recording temperature, and 37 national stream-quality accounting network stations were in operation. Tables describing the station location, type of data collected, and place where data are available are included, as well as maps showing the location of most of the stations. (USGS)
Dinkelacker, Vera; Xin, Xu; Baulac, Michel; Samson, Séverine; Dupont, Sophie
2016-09-01
Temporal lobe epilepsy (TLE) with hippocampal sclerosis has widespread effects on structural and functional connectivity and often entails cognitive dysfunction. EEG is mandatory to disentangle interactions in epileptic and physiological networks which underlie these cognitive comorbidities. Here, we examined how interictal epileptic discharges (IEDs) affect cognitive performance. Thirty-four patients (right TLE=17, left TLE=17) were examined with 24-hour video-EEG and a battery of neuropsychological tests to measure intelligence quotient and separate frontal and temporal lobe functions. Hippocampal segmentation of high-resolution T1-weighted imaging was performed with FreeSurfer. Partial correlations were used to compare the number and distribution of clinical interictal spikes and sharp waves with data from imagery and psychological tests. The number of IEDs was negatively correlated with executive functions, including verbal fluency and intelligence quotient (IQ). Interictal epileptic discharge affected cognitive function in patients with left and right TLE differentially, with verbal fluency strongly related to temporofrontal spiking. In contrast, IEDs had no clear effects on memory functions after corrections with partial correlations for age, age at disease onset, disease duration, and hippocampal volume. In patients with TLE of long duration, IED occurrence was strongly related to cognitive deficits, most pronounced for frontal lobe function. These data suggest that IEDs reflect dysfunctional brain circuitry and may serve as an independent biomarker for cognitive comorbidity. Copyright © 2016. Published by Elsevier Inc.
Influence Of Groundwater Discharge On Arsenic Contamination In Sediments
A field investigation was conducted to evaluate the impact of a discharging arsenic plume on sediment contaminant characteristics at a site adjacent to a landfill in northeastern Massachusetts. Site characterization included assessment of the hydrologic and chemical samples coll...
ISOLATION AND PARTIAL CHARACTERIZATION OF AN ACID PHOSPHATASE ACTIVITY FROM SPIRODELA OLIGORHIZA
An acid phosphatase activity from the aquatic plant Spirodela oligorhiza (duckweed) was isolated and partially characterized. S. oligorhiza was grown in a hydroponic growth medium, harvested, and ground up in liquid nitrogen. The ground plant material was added to a biological ...
Particle visualization in high-power impulse magnetron sputtering. II. Absolute density dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britun, Nikolay, E-mail: nikolay.britun@umons.ac.be; Palmucci, Maria; Konstantinidis, Stephanos
2015-04-28
Time-resolved characterization of an Ar-Ti high-power impulse magnetron sputtering discharge has been performed. The present, second, paper of the study is related to the discharge characterization in terms of the absolute density of species using resonant absorption spectroscopy. The results on the time-resolved density evolution of the neutral and singly-ionized Ti ground state atoms as well as the metastable Ti and Ar atoms during the discharge on- and off-time are presented. Among the others, the questions related to the inversion of population of the Ti energy sublevels, as well as to re-normalization of the two-dimensional density maps in terms ofmore » the absolute density of species, are stressed.« less
An Investigation of Low Earth Orbit Internal Charging
NASA Technical Reports Server (NTRS)
NeergaardParker, Linda; Minow, Joseph I.; Willis, Emily M.
2014-01-01
Low Earth orbit is usually considered a relatively benign environment for internal charging threats due to the low flux of penetrating electrons with energies of a few MeV that are encountered over an orbit. There are configurations, however, where insulators and ungrounded conductors used on the outside of a spacecraft hull may charge when exposed to much lower energy electrons of some 100's keV in a process that is better characterized as internal charging than surface charging. For example, the minimal radiation shielding afforded by thin thermal control materials such as metalized polymer sheets (e.g., aluminized Kapton or Mylar) and multilayer insulation may allow electrons of 100's of keV to charge underlying materials. Yet these same thermal control materials protect the underlying insulators and ungrounded conductors from surface charging currents due to electrons and ions at energies less than a few keV as well as suppress the photoemission, secondary electron, and backscattered electron processes associated with surface charging. We investigate the conditions required for this low Earth orbit "internal charging" to occur and evaluate the environments for which the process may be a threat to spacecraft. First, we describe a simple one-dimensional internal charging model that is used to compute the charge accumulation on materials under thin shielding. Only the electron flux that penetrates exposed surface shielding material is considered and we treat the charge balance in underlying insulation as a parallel plate capacitor accumulating charge from the penetrating electron flux and losing charge due to conduction to a ground plane. Charge dissipation due to conduction can be neglected to consider the effects of charging an ungrounded conductor. In both cases, the potential and electric field is computed as a function of time. An additional charge loss process is introduced due to an electrostatic discharge current when the electric field reaches a prescribed breakdown strength. For simplicity, the amount of charge lost in the discharge is treated as a random percentage of the total charge between a set maximum and minimum amount so a user can consider partial discharges of insulating materials (small loss of charge) or arcing from a conductor (large loss of charge). We apply the model to electron flux measurements from the NOAA-19 spacecraft to demonstrate that charging can reach levels where electrostatic discharges occur and estimate the magnitude of the discharge.
NASA Astrophysics Data System (ADS)
Biancamaria, S.; Frappart, F.; Normandin, C.; Blarel, F.; Bourrel, L.; Aumont, M.; Azema, P.; Vu, P. L.; Lubac, B.; Darrozes, J.
2017-12-01
The Tonle Sap lake is the largest freshwater lake in Southeast Asia and is located within the Mekong basin (mainly in Cambodia). It is one of he most productive ecosystem of the world and provide two thirds of Cambodia fish catch. It also plays a unique role on the Mekong basin hydrological cycle: during the monsoon period, the Mekong river partially flows to the lake, whereas during the dry season, the lake flows to the Mekong delta. It is therefore crucial to monitor and take into account this lake to estimate Mekong discharge to the ocean. However, in situ measurements of lake level and river discharge are very sparse (especially during the last decades) and computing lake storage variation from in situ data only is difficult due to the huge annual variation of lake area. That's why, satellite data (nadir radar altimetry and visible imagery) have been used to study its volume variation and its relationship with climate events and Mekong river discharge. Multi-mission altimetry data have been extracted (Topex, ERS-2, ENVISAT, Jason-1, Jason-2, Saral and Jason-3, using CTOH data extraction tools) to derive a lake water level from1993 to 2016, which varies from 3 m to 12 m. Lake area have been computed from MODIS data from 2000 to 2016 and varies from 3,400 km2 to 11,800 km2. These dataset clearly shows a relationship between lake water level and area, which has been used to estimate lake water volume change from 1995 to 2016, with a minimum in 2015 and a maximum in 2011. Lake's droughts and floods can be observed during moderate and strong El Nino/La Nina events, enhanced by the Pacific Decadal Oscillation. Besides, comparison with in situ discharge at the outlet of the Mekong basin (over 1995/2000 time period) shows that lake water level is 20 days time lagged and increases/decreases after Mekong discharge at its outlet. This time lag results of Mekong river partially flowing to the lake. Finally, high correlation between lake level and outlet discharge allows to use lake water level to derive Mekong discharge at its outlet after 2000, when in situ time series are not available anymore to the international scientific community. In the future, to improve time sampling, Sentinel-2 images and data from Sentinel-3 altimeter will be used.
Water resources data, Arkansas, 2002
Brossett, T.H.; Evans, D.A.
2003-01-01
Water resources data for the 2002 water year for Arkansas consist of records of discharge and water quality (physical measurements and chemical concentrations) of streams, water quality of lakes, and groundwater levels and ground-water quality. Data from selected sites in Missouri and Oklahoma also are included. This report contains daily discharge records for 108 surface-water gaging stations and 87 peak-discharge partial-record stations, water-quality data for 65 surface-water stations and 5 wells, and water levels for 15 observation wells. Additional water data were collected at various sites, not part of the systematic data-collection program, and are published as miscellaneous measurements. Note: Historically, this report has been published as a paper report. Beginning with the 2002 water year report, these reports will be available from the World Wide Web at http://ar.water.usgs.gov.
Water Resources Data, Kansas, Water Year 2001
Putnam, J.E.; Lacock, D.L.; Schneider, D.R.
2002-01-01
Water-resources data for the 2001 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 145 complete-record gaging stations; elevation and contents at 20 lakes and reservoirs; waterquality records at 2 precipitation stations, water-level data at 19 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 11 gaging stations. Also included are discharge data for 26 high-flow partial-record stations, miscellaneous onsite water-quality data collected at 140 stations, and suspended-sediment concentration for 12 stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.
Water Resources Data, Kansas, Water Year 2002
Putnam, J.E.; Schneider, D.R.
2003-01-01
Water-resources data for the 2002 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 149 complete-record gaging stations; elevation and contents at 20 lakes and reservoirs; waterquality records at 2 precipitation stations, water-level data at 18 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 11 gaging stations. Also included are discharge data for 26 high-flow partial-record stations, miscellaneous onsite water-quality data collected at 142 stations, and suspended-sediment concentration for 12 stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.
Water Resources Data, Kansas, Water Year 2000
Putnam, J.E.; Lacock, D.L.; Schneider, D.R.; Carlson, M.D.
2001-01-01
Water-resources data for the 2000 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 144 complete-record gaging stations; elevation and contents at 19 lakes and reservoirs; water-quality records at 2 precipitation stations, water-level data at 18 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 8 gaging stations. Also included are discharge data for 26 high-flow partial-record stations, and miscellaneous onsite water-quality data collected at 134 stations, and suspended-sediment concentration for 12 stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.
Evaluation of 20 Ah Li Ion Cells
NASA Technical Reports Server (NTRS)
Smart, Marshall; Ratnakumar, B. V.; Huang, Charles K.; Surampudi, S.; Hill, Carole; Radzykewycz, Dan T.; Marsh, Richard A.
1998-01-01
Lithium ion cells of 20 Ah capacity were fabricated by Bluestar Advanced Technology Corporation, Canada under a developmental contract from US Air Force. In this paper, we report our studies on the evaluation of these cells under various test conditions. These include generic test conditions such as discharges and charges at different temperatures to understand the rate-limiting processes in the discharge/charge processes as a function of temperature, and cycle life under standard cycling conditions (100% DOD) at ambient temperature. In addition, tests are being done to ascertain the performance of the cells in the Mars 2001 Lander application, which includes pulse testing of the cells at 60 A and 40 A loads for 100 mS and 1 min., respectively at different states of charge and temperatures, and cycling at low temperature at partial depths of discharge.
Naz, M. Y.; Sulaiman, S. A.; Ariwahjoedi, B.; Shaari, Ku Zilati Ku
2014-01-01
The objective of the research was to understand and improve the unusual physical and atomization properties of the complexes/adhesives derived from the tapioca starch by addition of borate and urea. The characterization of physical properties of the synthesized adhesives was carried out by determining the effect of temperature, shear rate, and mass concentration of thickener/stabilizer on the complex viscosity, density, and surface tension. In later stage, phenomenological analyses of spray jet breakup of heated complexes were performed in still air. Using a high speed digital camera, the jet breakup dynamics were visualized as a function of the system input parameters. The further analysis of the grabbed images confirmed the strong influence of the input processing parameters on full cone spray patternation. It was also predicted that the heated starch adhesive solutions generate a dispersed spray pattern by utilizing the partial evaporation of the spraying medium. Below 40°C of heating temperature, the radial spray cone width and angle did not vary significantly with increasing Reynolds and Weber numbers at early injection phases leading to increased macroscopic spray propagation. The discharge coefficient, mean flow rate, and mean flow velocity were significantly influenced by the load pressure but less affected by the temperature. PMID:24592165
Lithium-manganese dioxide cells for implantable defibrillator devices-Discharge voltage models
NASA Astrophysics Data System (ADS)
Root, Michael J.
The discharge potential behavior of lithium-manganese dioxide cells designed for implantable cardiac defibrillators was characterized as a function of extent of cell depletion for tests designed to discharge the cells for times between 1 and 7 years. The discharge potential curves may be separated into two segments from 0 ≤ x ≤ ∼0.51 and ∼0.51 ≤ x ≤ 1.00, where x is the dimensionless extent of discharge referenced to the rated cell capacity. The discharge potentials conform to Tafel kinetics in each segment. This behavior allows the discharge potential curves to be predicted for an arbitrary discharge load and long term discharge performance may be predicted from short term test results. The discharge potentials may subsequently be modeled by fitting the discharge curves to empirical functions like polynomials and Padé approximants. A function based on the Nernst equation that includes a term accounting for nonideal interactions between lithium ions and the cathode host material, such as the Redlich-Kister relationship, also may be used to predict discharge behavior.
2011-03-24
and radiation resistance of rare earth permanent magnets for applications such as ion thrusters and high efficiency Stirling Radioisotope Generators...from Electron Transitioning Discharge Current Discharge Power Discharge Voltage Θ Divergence Angle Earths Gravity at Sea Level...Hall effect thruster HIVAC High Voltage Hall Accelerator LEO Low Earth Orbit LDS Laser Displacement System LVDT Linear variable differential
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stenina, I.A.; Kulova, T.L.; Skundin, A.M.
2016-03-15
Highlights: • Li{sub 4}Ti{sub 5}O{sub 12}/TiO{sub 2} nanocomposites with high grain boundary density were synthesized. • {sup 7}Li NMR and impedance spectroscopy shows high Li-ion mobility in nanocomposites. • The shape of charge/discharge curves changes for nanocomposites. • Influence of particle size on cycling performance of lithium titanates was shown. • Li{sub 4}Ti{sub 5}O{sub 12}/TiO{sub 2} nanocomposite exhibits good cycling performance and rate capability. - Abstract: Li{sub 4}Ti{sub 5}O{sub 12}/TiO{sub 2} nanocomposites are synthesized by a sol-gel method. The size of Li{sub 4}Ti{sub 5}O{sub 12} and TiO{sub 2} particles is of 4–5 and 7–10 nm, respectively. The obtained materials aremore » characterized by XRD, SEM, HRTEM and BET. Ion mobility of the composites and their performance as anode materials for lithium-ion batteries are studied. According to the conductivity and {sup 7}Li NMR data, Li{sup +} mobility is much higher in the Li{sub 4}Ti{sub 5}O{sub 12}/TiO{sub 2} nanocomposites as compared with that in pure Li{sub 4}Ti{sub 5}O{sub 12}. For Li{sub 4}Ti{sub 5}O{sub 12}/TiO{sub 2} nanocomposites, marked changes in the charge–discharge curves are observed; charge–discharge rate and effective capacity at a high cycling rate are shown to increase. During the first cycle, charge capacity of these materials surpasses the theoretical capacity of Li{sub 4}Ti{sub 5}O{sub 12}. However, this parameter decreases sharply with cycling, whereas the discharge capacity remains almost unchanged. This phenomenon is attributed to the solid electrolyte interphase formation due to a partial electrolyte reduction on the Li{sub 4}Ti{sub 5}O{sub 12}/TiO{sub 2} composite surface.« less
NASA Technical Reports Server (NTRS)
Hallock, Ashley; Polzin, Kurt; Emsellem, Gregory
2012-01-01
Pulsed inductive plasma thrusters [1-3] are spacecraft propulsion devices in which electrical energy is capacitively stored and then discharged through an inductive coil. The thruster is electrodeless, with a time-varying current in the coil interacting with a plasma covering the face of the coil to induce a plasma current. Propellant is accelerated and expelled at a high exhaust velocity (O(10-100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, pulsed inductive plasma thrusters require high pulse energies to inductively ionize propellant. The Microwave Assisted Discharge Inductive Plasma Accelerator (MAD-IPA) [4, 5] is a pulsed inductive plasma thruster that addressees this issue by partially ionizing propellant inside a conical inductive coil via an electron cyclotron resonance (ECR) discharge. The ECR plasma is produced using microwaves and permanent magnets that are arranged to create a thin resonance region along the inner surface of the coil, restricting plasma formation, and in turn current sheet formation, to a region where the magnetic coupling between the plasma and the inductive coil is high. The use of a conical theta-pinch coil is under investigation. The conical geometry serves to provide neutral propellant containment and plasma plume focusing that is improved relative to the more common planar geometry of the Pulsed Inductive Thruster (PIT) [2, 3], however a conical coil imparts a direct radial acceleration of the current sheet that serves to rapidly decouple the propellant from the coil, limiting the direct axial electromagnetic acceleration in favor of an indirect acceleration mechanism that requires significant heating of the propellant within the volume bounded by the current sheet. In this paper, we describe thrust stand measurements performed to characterize the performance (specific impulse, thrust efficiency) of the MAD-IPA thruster. Impulse data are obtained at various pulse energies, mass flow rates and inductive coil. geometries. Dependencies on these experimental parameters are discussed in the context of the current sheet formation and electromagnetic plasma acceleration processes.
PARTIAL CHARACTERIZATION OF ALLERGENS IN EXTRACTS OF STACHYBOTRYS CHARTARUM
PARTIAL CHARACTERIZATION OF ALLERGENS IN EXTRACTS OF Stachybotrys chartarum. M E Viana1, MJ Selgrade2, and M D Ward2. 1NCSU, Raleigh, NC, USA. 2NHEERL, ORD, US EPA, RTP, NC, USA.
Exposure to Stachybotrys chartarum has been associated with the development of serious health ...
An acid phosphatase from the aquatic plant Spirodela oligorrhiza (duckweed) was isolated by fast protein liquid chromatography (FPLC) and partially characterized. The enzyme was purified 1871-fold with a total yield of 40%. SDS-PAGE electrophoresis of the pure acid phosphatase ...
NASA Astrophysics Data System (ADS)
Hdeib, Rouya; Abdallah, Chadi; Moussa, Roger; Colin, Francois
2017-04-01
Developing flood inundation maps of defined exceedance probabilities is required to provide information on the flood hazard and the associated risk. A methodology has been developed to model flood inundation in poorly gauged basins, where reliable information on the hydrological characteristics of floods are uncertain and partially captured by the traditional rain-gauge networks. Flood inundation is performed through coupling a hydrological rainfall-runoff (RR) model (HEC-HMS) with a hydraulic model (HEC-RAS). The RR model is calibrated against the January 2013 flood event in the Awali River basin, Lebanon (300 km2), whose flood peak discharge was estimated by post-event measurements. The resulting flows of the RR model are defined as boundary conditions of the hydraulic model, which is run to generate the corresponding water surface profiles and calibrated against 20 post-event surveyed cross sections after the January-2013 flood event. An uncertainty analysis is performed to assess the results of the models. Consequently, the coupled flood inundation model is simulated with design storms and flood inundation maps are generated of defined exceedance probabilities. The peak discharges estimated by the simulated RR model were in close agreement with the results from different empirical and statistical methods. This methodology can be extended to other poorly gauged basins facing common stage-gauge failure or characterized by floods with a stage exceeding the gauge measurement level, or higher than that defined by the rating curve.
Curia, Giulia; Biagini, Giuseppe; Perucca, Emilio; Avoli, Massimo
2016-01-01
The mechanism of action of several antiepileptic drugs (AEDs) rests on their ability to modulate the activity of voltage-gated sodium currents that are responsible for fast action potential generation. Recent data indicate that lacosamide (a compound with analgesic and anticonvulsant effects in animal models) shares a similar mechanism. When compared with other AEDs, lacosamide has the unique ability to interact with sodium channel slow inactivation without affecting fast inactivation. This article reviews these findings and discusses their relevance within the context of neuronal activity seen during epileptiform discharges generated by limbic neuronal networks in the presence of chemical convulsants. These seizure-like events are characterized by sustained discharges of sodium-dependent action potentials supported by robust depolarizations, thus providing synchronization within neuronal networks. Generally, AEDs such as phenytoin, carbamazepine and lamotrigine block sodium channels when activated. In contrast, lacosamide facilitates slow inactivation of sodium channels both in terms of kinetics and voltage dependency. This effect may be relatively selective for repeatedly depolarized neurons, such as those participating in seizure activity in which the persistence of sodium currents is more pronounced and promotes neuronal excitation. The clinical effectiveness of lacosamide has been demonstrated in randomized, double-blind, parallel-group, placebo-controlled, adjunctive-therapy trials in patients with refractory partial seizures. Further studies should determine whether the effects of lacosamide in animal models and in clinical settings are fully explained by its selective action on sodium current slow inactivation or whether other effects (e.g. interactions with the collapsin-response mediator protein-2) play a contributory role. PMID:19552484
Electrical Activity in Martian Dust Storms
NASA Astrophysics Data System (ADS)
Majid, W.; Arabshahi, S.; Kocz, J.
2016-12-01
Dust storms on Mars are predicted to be capable of producing electrostatic fields and discharges, even larger than those in dust storms on Earth. Such electrical activity poses serious risks to any Human exploration of the planet and the lack of sufficient data to characterize any such activity has been identified by NASA's MEPAG as a key human safety knowledge gap. There are three key elements in the characterization of Martian electrostatic discharges: dependence on Martian environmental conditions, frequency of occurrence, and the strength of the generated electric fields. We will describe a recently deployed detection engine using NASA's Deep Space Network (DSN) to carry out a long term monitoring campaign to search for and characterize the entire Mars hemisphere for powerful discharges during routine tracking of spacecraft at Mars on an entirely non-interfering basis. The resulting knowledge of Mars electrical activity would allow NASA to plan risk mitigation measures to ensure human safety during Mars exploration. In addition, these measurements will also allow us to place limits on presence of oxidants such as H2O2 that may be produced by such discharges, providing another measurement point for models describing Martian atmospheric chemistry and habitability. Because of the continuous Mars telecommunication needs of NASA's Mars-based assets, the DSN is the only instrument in the world that combines long term, high cadence, observing opportunities with large sensitive telescopes, making it a unique asset worldwide in searching for and characterizing electrostatic activity at Mars from the ground.
Radio Emissions from Electrical Activity in Martian Dust Storms
NASA Astrophysics Data System (ADS)
Majid, W.; Arabshahi, S.; Kocz, J.; Schulter, T.; White, L.
2017-12-01
Dust storms on Mars are predicted to be capable of producing electrostatic fields and discharges, even larger than those in dust storms on Earth. There are three key elements in the characterization of Martian electrostatic discharges: dependence on Martian environmental conditions, event rate, and the strength of the generated electric fields. The detection and characterization of electric activity in Martian dust storms has important implications for habitability, and preparations for human exploration of the red planet. Furthermore, electrostatic discharges may be linked to local chemistry and plays an important role in the predicted global electrical circuit. Because of the continuous Mars telecommunication needs of NASA's Mars-based assets, the Deep Space Network (DSN) is the only facility in the world that combines long term, high cadence, observing opportunities with large sensitive telescopes, making it a unique asset worldwide in searching for and characterizing electrostatic activity from large scale convective dust storms at Mars. We will describe a newly inaugurated program at NASA's Madrid Deep Space Communication Complex to carry out a long-term monitoring campaign to search for and characterize the entire Mars hemisphere for powerful discharges during routine tracking of spacecraft at Mars on an entirely non-interfering basis. The ground-based detections will also have important implications for the design of a future instrument that could make similar in-situ measurements from orbit or from the surface of Mars, with far greater sensitivity and duty cycle, opening up a new window in our understanding of the Martian environment.
Synthesis, characterization and application of doped electrolytic manganese dioxides
NASA Astrophysics Data System (ADS)
Jantscher, Wolfgang; Binder, Leo; Fiedler, Dirk A.; Andreaus, Reinhard; Kordesch, Karl
Electrolytic manganese dioxides (EMDs) were prepared on the 100 g scale by anodic deposition from acidic aqueous solutions of manganese sulfate. In situ doping with titanium ions was achieved by addition of tetra- n-butoxytitanium to the electrolytic bath. Samples were also doped ex situ by washing the products with aqueous barium hydroxide solution. The EMDs were characterized by electron microscopy studies and BET surface area determinations. Cyclic abrasive stripping voltammetry was successfully applied to evaluate the rechargeability of the newly synthesized undoped and doped EMDs in 9 M KOH. Relative discharge capacities at different depths of discharge (DOD) with respect to the first one-electron reduction of γ-MnO 2 are compared for different EMDs. At about 30% DOD, resulting relative discharge capacities show essentially the same trend as those measured in AA cells from about 10 to 20 discharge/charge cycles onwards. Accordingly, titanium-doped EMD was shown to exhibit superior charge retention and rechargeability when compared to the titanium-free samples.
An experimental and modeling study of isothermal charge/discharge behavior of commercial Ni-MH cells
NASA Astrophysics Data System (ADS)
Pan, Y. H.; Srinivasan, V.; Wang, C. Y.
In this study, a previously developed nickel-metal hydride (Ni-MH) battery model is applied in conjunction with experimental characterization. Important geometric parameters, including the active surface area and micro-diffusion length for both electrodes, are measured and incorporated in the model. The kinetic parameters of the oxygen evolution reaction are also characterized using constant potential experiments. Two separate equilibrium equations for the Ni electrode, one for charge and the other for discharge, are determined to provide a better description of the electrode hysteresis effect, and their use results in better agreement of simulation results with experimental data on both charge and discharge. The Ni electrode kinetic parameters are re-calibrated for the battery studied. The Ni-MH cell model coupled with the updated electrochemical properties is then used to simulate a wide range of experimental discharge and charge curves with satisfactory agreement. The experimentally validated model is used to predict and compare various charge algorithms so as to provide guidelines for application-specific optimization.
Sensitivity of RF-driven Plasma Filaments to Trace Gases
NASA Astrophysics Data System (ADS)
Burin, M. J.; Czarnocki, C. J.; Czarnocki, K.; Zweben, S. J.; Zwicker, A.
2011-10-01
Filamentary structures have been observed in many types of plasma discharges in both natural (e.g. lightning) and industrial systems (e.g. dielectric barrier discharges). Recent progress has been made in characterizing these structures, though various aspects of their essential physics remain unclear. A common example of this phenomenon can be found within a toy plasma globe (or plasma ball), wherein a primarily neon gas mixture near atmospheric pressure clearly and aesthetically displays filamentation. Recent work has provided the first characterization of these plasma globe filaments [Campanell et al., Physics of Plasmas 2010], where it was noticed that discharges of pure gases tend not to produce filaments. We have extended this initial work to investigate in greater detail the dependence of trace gases on filamentation within a primarily Neon discharge. Our preliminary results using a custom globe apparatus will be presented, along with some discussion of voltage dependencies. Newly supported by the NSF/DOE Partnership in Basic Plasma Science and Engineering.
Along-arc distribution of 3He/4He and 87Sr/86Sr in thermal fluids of the Kuril Island arc (Russia)
NASA Astrophysics Data System (ADS)
Taran, Y.; Kalacheva, E.; Bujakajte, M.; Inguaggiato, S.
2017-12-01
The Kuril Island arc in the NW Pacific extends for 1200 km from the Kamchatka Peninsula to Hokkaido Islandand separates the margin Sea of Okhotsk from the Pacific Ocean. Among 40 active volcanoes at least 7 are characterized by strong and high-temperature fumarolic activity, 1 to 3 volcanoes are erupting right now, and many of active and dormant volcanoes host hydrothermal systems. We report our data on hydrochemistry and isotopic composition of He and Sr from fumarolic and hydrothermal discharges sampled along the arc, from Ebeko volcano on Paramushir Island to Golovnin volcano on Kunashir Island. The data were obtained during the field campaign in 2015-2017. Most of hydrothermal systems of Kuril Islands discharge acid-to-ultra acid SO4-Cl and Cl-SO4 waters and steam-heated SO4 waters. On some islands, like Shiashkotan, northern Kurils, coastal hot springs can be found issuing Na-Cl waters mixed with seawater. Mature Na-Cl waters are known only on southern big islands Iturup and Kunashir. The distribution of 3He/4He in hydrothermal and fumarolic gases along the arc is very uniform with 3He/4He values close to the MORB value of 8Ra where Ra is atmospheric ratio (1.4 x 10-6). The northernmost Ebeko volcano discharges fumaroles with 3He/4He up to 7.9Ra, and bubbling gas in the nearest hot springs up to 7.6Ra. Such high 3He/4He values with a maximum of 8.3Ra in fumaroles of the Pallas Peak in the middle of the arc were measured in all thermal manifestations of the arc (fumaroles, hydrothermal steam vents and bubbling gases) up to the southernmost Kunashir Island, where volcanic and hydrothermal gases are characterized by significantly lower values of 5.5Ra at Mendeleev volcano and 3.5Ra at Golovnin volcano. Isotopic ratio of the dissolved Sr as a rule corresponds to the 87Sr/86Sr values of the host rocks and only in the coastal hot springs demonstrates partial mixing with seawater. There is also a general consistence of 87Sr/86Sr in springs and 3He/4He in gases. This study was supported by the Russian Science Foundation grant # 15-17-20011.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
... (soil and groundwater) of the properties proposed for deletion. DATES: This direct final partial... site media, including soil and groundwater for the following properties: Properties owned by the Town... streams were finally directed to the WWTP. As a result of these discharges, overburden soil and bedrock...
theoretically. Negative ions are produced by a corona discharge from a needle placed along the axis of a nozzle. A dense air-vapor mixture is...interaction with the gas molecules to an electrode of high potential. The effectiveness of the viscous coupling depends on the charge mobility being
1985-09-23
34" .-* .V° --. ° "’" . y-. " .,- .r- ..-- . ru-. . La.L 4.’. C’... o 0 0 I,-- E - o Q0 Ldhi z0 LA-, =E ;’-’. -0 L.C AA. r- 0"" 7-- ., I-:. ILI.’ I I I
Experimental results on the influence of fluxes on partial discharge onset in PCB solder joints
NASA Astrophysics Data System (ADS)
Bulletti, Andrea; Capineri, Lorenzo; Materassi, Maurizio
2003-09-01
This work concerns the development of an experimental set-up for assessing the influence of fluxes on Partial Discharge (PD) onset in High Voltage (HV) devices soldered on Printed Circuit Boards (PCBs). In particular, the work considered the effects of three types of fluxes chosen in agreement with the directions of the Materials and Processes Division at ESA/ESTEC. Contaminated samples are formed by a standard FR-4 PCB board with a pair of copper electrodes and a protocol of contamination has been applied for all samples. The measuring system is placed inside a shielded chamber and provides measurements of Corona Inception Voltage (CIV), Corona Extinction Voltage (CEV) and PD amplitudes collected in a vacuum chamber with controlled temperature fixture. The results shows that flux Alpha 850-33 has the mean CIV smaller than other types of fluxes and the same result is observed for the mean CEV. Also the PD amplitudes are greater for samples contaminated with flux Alpha 850-33 than the other two types and similar in value for samples without flux.
NASA Astrophysics Data System (ADS)
Wei, B. G.; Huo, K. X.; Yao, Z. F.; Lou, J.; Li, X. Y.
2018-03-01
It is one of the difficult problems encountered in the research of condition maintenance technology of transformers to recognize partial discharge (PD) pattern. According to the main physical characteristics of PD, three models of oil-paper insulation defects were set up in laboratory to study the PD of transformers, and phase resolved partial discharge (PRPD) was constructed. By using least square method, the grey-scale images of PRPD were constructed and features of each grey-scale image were 28 box dimensions and 28 information dimensions. Affinity propagation algorithm based on manifold distance (AP-MD) for transformers PD pattern recognition was established, and the data of box dimension and information dimension were clustered based on AP-MD. Study shows that clustering result of AP-MD is better than the results of affinity propagation (AP), k-means and fuzzy c-means algorithm (FCM). By choosing different k values of k-nearest neighbor, we find clustering accuracy of AP-MD falls when k value is larger or smaller, and the optimal k value depends on sample size.
Low-flow characteristics for selected streams in Indiana
Fowler, Kathleen K.; Wilson, John T.
2015-01-01
The management and availability of Indiana’s water resources increase in importance every year. Specifically, information on low-flow characteristics of streams is essential to State water-management agencies. These agencies need low-flow information when working with issues related to irrigation, municipal and industrial water supplies, fish and wildlife protection, and the dilution of waste. Industrial, municipal, and other facilities must obtain National Pollutant Discharge Elimination System (NPDES) permits if their discharges go directly to surface waters. The Indiana Department of Environmental Management (IDEM) requires low-flow statistics in order to administer the NPDES permit program. Low-flow-frequency characteristics were computed for 272 continuous-record stations. The information includes low-flow-frequency analysis, flow-duration analysis, and harmonic mean for the continuous-record stations. For those stations affected by some form of regulation, low-flow frequency curves are based on the longest period of homogeneous record under current conditions. Low-flow-frequency values and harmonic mean flow (if sufficient data were available) were estimated for the 166 partial-record stations. Partial-record stations are ungaged sites where streamflow measurements were made at base flow.
Álvarez, Fernando; Garnacho, Fernando; Ortego, Javier; Sánchez-Urán, Miguel Ángel
2015-01-01
Partial discharge (PD) measurements provide valuable information for assessing the condition of high voltage (HV) insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years specially designed to perform on-line measurements. Non-conventional PD methods operating in high frequency bands are usually used when this type of tests are carried out. In PD measurements the signal acquisition, the subsequent signal processing and the capability to obtain an accurate diagnosis are conditioned by the selection of a suitable detection technique and by the implementation of effective signal processing tools. This paper proposes an optimized electromagnetic detection method based on the combined use of wideband PD sensors for measurements performed in the HF and UHF frequency ranges, together with the implementation of powerful processing tools. The effectiveness of the measuring techniques proposed is demonstrated through an example, where several PD sources are measured simultaneously in a HV installation consisting of a cable system connected by a plug-in terminal to a gas insulated substation (GIS) compartment. PMID:25815452
A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System
Zhang, Tongzhi; Pang, Fufei; Liu, Huanhuan; Cheng, Jiajing; Lv, Longbao; Zhang, Xiaobei; Chen, Na; Wang, Tingyun
2016-01-01
We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad/(m⋅Pa). A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work. PMID:27916900
Xie, Qing; Tao, Junhan; Wang, Yongqiang; Geng, Jianghai; Cheng, Shuyi; Lü, Fangcheng
2014-08-01
Fast and accurate positioning of partial discharge (PD) sources in transformer oil is very important for the safe, stable operation of power systems because it allows timely elimination of insulation faults. There is usually more than one PD source once an insulation fault occurs in the transformer oil. This study, which has both theoretical and practical significance, proposes a method of identifying multiple PD sources in the transformer oil. The method combines the two-sided correlation transformation algorithm in the broadband signal focusing and the modified Gerschgorin disk estimator. The method of classification of multiple signals is used to determine the directions of arrival of signals from multiple PD sources. The ultrasonic array positioning method is based on the multi-platform direction finding and the global optimization searching. Both the 4 × 4 square planar ultrasonic sensor array and the ultrasonic array detection platform are built to test the method of identifying and positioning multiple PD sources. The obtained results verify the validity and the engineering practicability of this method.
Partial detachment of high power discharges in ASDEX Upgrade
NASA Astrophysics Data System (ADS)
Kallenbach, A.; Bernert, M.; Beurskens, M.; Casali, L.; Dunne, M.; Eich, T.; Giannone, L.; Herrmann, A.; Maraschek, M.; Potzel, S.; Reimold, F.; Rohde, V.; Schweinzer, J.; Viezzer, E.; Wischmeier, M.; the ASDEX Upgrade Team
2015-05-01
Detachment of high power discharges is obtained in ASDEX Upgrade by simultaneous feedback control of core radiation and divertor radiation or thermoelectric currents by the injection of radiating impurities. So far 2/3 of the ITER normalized heat flux Psep/R = 15 MW m-1 has been obtained in ASDEX Upgrade under partially detached conditions with a peak target heat flux well below 10 MW m-2. When the detachment is further pronounced towards lower peak heat flux at the target, substantial changes in edge localized mode (ELM) behaviour, density and radiation distribution occur. The time-averaged peak heat flux at both divertor targets can be reduced below 2 MW m-2, which offers an attractive DEMO divertor scenario with potential for simpler and cheaper technical solutions. Generally, pronounced detachment leads to a pedestal and core density rise by about 20-40%, moderate (<20%) confinement degradation and a reduction of ELM size. For AUG conditions, some operational challenges occur, like the density cut-off limit for X-2 electron cyclotron resonance heating, which is used for central tungsten control.
Controlled synthesis of different metal oxide nanostructures by direct current arc discharge.
Su, Yanjie; Zhang, Jing; Zhang, Liling; Zhang, Yafei
2013-02-01
Direct current (DC) arc discharge method gives high temperature in a short time, which has been widely used to prepare carbon nanotubes. We use this simple approach to synthesize metal oxide nanostructures (MgO, SnO2) without any catalyst. Different morphologies (nanowires, nanobelts, nanocubes, and nanodisks) of metal oxide nanostructures can be controllably synthesized by changing the content of air in buffer gas. The growth mechanisms for these nanostructures are discussed in detail. Oxygen partial pressure is supposed to be one of the most important key factors. The methodology might be used to synthesize similar nanostructures of other functional oxide materials and non-oxide materials.
Oxidation of aqueous pharmaceuticals by pulsed corona discharge.
Panorel, Iris; Preis, Sergei; Kornev, Iakov; Hatakka, Henry; Louhi-Kultanen, Marjatta
2013-01-01
Oxidation of aromatic compounds of phenolic (paracetamol, beta-oestradiol and salicylic acid) and carboxylic (indomethacin and ibuprofen) structure used in pharmaceutics was studied. Aqueous solutions were treated with pulsed corona discharge (PCD) as a means for advanced oxidation. Pulse repetition frequency, delivered energy dose and oxidation media were the main parameters studied for their influence on the process energy efficiency. The PCD treatment appeared to be effective in oxidation of the target compounds: complete degradation of pollutant together with partial mineralization was achieved at moderate energy consumption; oxidation proceeds faster in alkaline media. Low-molecular carboxylic acids were identified as ultimate oxidation by-products formed in the reaction.
Cho, Moon Kyoung; Kim, Chul Hong; Kim, Yoon Ha
2011-11-01
We present here the case report of a postmenopausal woman who complained of recurrent pus-like vaginal discharge and perianal pain 1 year after Le Fort colpocleisis, which was subsequently identified as a primary invasive carcinoma of the vagina. Biopsy confirmed a squamous cell carcinoma in the vagina, and the disease was classified as stage III according to FIGO staging. The patient received pelvic radiotherapy. This case emphasizes that differential diagnosis of recurrent vaginal discharge that presents remote from obliterative procedure for pelvic organ prolapse should consider not only pyometra, but also other causes.
Discharge variability and bedrock river incision on the Hawaiian island of Kaua'i
NASA Astrophysics Data System (ADS)
Huppert, K.; Deal, E.; Perron, J. T.; Ferrier, K.; Braun, J.
2017-12-01
Bedrock river incision occurs during floods that generate sufficient shear stress to strip riverbeds of sediment cover and erode underlying bedrock. Thresholds for incision can prevent erosion at low flows and slow down erosion at higher flows that do generate excess shear stress. Because discharge distributions typically display power-law tails, with non-negligible frequencies of floods much greater than the mean, models incorporating stochastic discharge and incision thresholds predict that discharge variability can sometimes have greater effects on long-term incision rates than mean discharge. This occurs when the commonly observed inverse scalings between mean discharge and discharge variability are weak or when incision thresholds are high. Because the effects of thresholds and discharge variability have only been documented in a few locations, their influence on long-term river incision rates remains uncertain. The Hawaiian island of Kaua'i provides an ideal natural laboratory to evaluate the effects of discharge variability and thresholds on bedrock river incision because it has one of Earth's steepest spatial gradients in mean annual rainfall and it also experiences dramatic spatial variations in rainfall and discharge variability, spanning a wide range of the conditions reported on Earth. Kaua'i otherwise has minimal variations in lithology, vertical motion, and other factors that can influence erosion. River incision rates averaged over 1.5 - 4.5 Myr timescales can be estimated along the lengths of Kauaian channels from the depths of river canyons and lava flow ages. We characterize rainfall and discharge variability on Kaua'i using records from an extensive network of rain and stream gauges spanning the past century. We use these characterizations to model long-term bedrock river incision along Kauaian channels with a threshold-dependent incision law, modulated by site-specific discharge-channel width scalings. Our comparisons between modeled and observed erosion rates suggest that variations in river incision rates on Kaua'i are dominated by variations in mean rainfall and discharge, rather than by differences in storminess across the island. We explore the implications of this result for the threshold dependence of river incision across Earth's varied climates.
NASA Astrophysics Data System (ADS)
Baranov, G. A.; Efremov, Yu V.; Smirnov, A. S.; Frolov, K. S.; Shevchenko, Yu I.
1989-02-01
An investigation was made of the distributions of the gain and input energy per unit volume along the discharge chamber length in a CO2-N2-He mixture stream excited by an rf discharge. The dependences of the gain and discharge luminescence intensity on the coordinate x were determined along the direction of the gas flow. The discharge luminescence intensity was shown to characterize the input energy distribution along the X axis. Calculations were made of the small-signal gain in the rf discharge. Experimental data on the distributions of the input energy and of the electric field in the discharge and the average values of the kinetic coefficients were used in the calculations. The efficiency of pumping CO2 lasers with an rf discharge was found to be close to the dc pumping efficiency. The results obtained provide evidence of promising prospects for using an rf discharge in fast-flow industrial lasers.
Patterns of Care, Utilization, and Outcomes of Treatments for Localized Prostate Cancer
2012-05-01
Hospital length of stay ( LOS ) was defined as the 148 interval between hospital admission to discharge. Blood transfusions were characterized during...wound, miscellaneous medical, and miscellaneous 301 surgical). NIS-specific outcomes included death, hospital length of stay ( LOS ), discharge 302...Low volume 340 hospitals had longer mean LOS (p<.01) and fewer routine home discharges (p<.01). Finally, 341 higher RALP hospital volume was
2014-06-01
TECHNICAL REPORT 2077 June 2014 Modeling Tool to Quantify Metal Sources in Stormwater Discharges at Naval Facilities (NESDI Project 455... Stormwater Discharges at Naval Facilities (NESDI Project 455) Final Report and Guidance C. Katz K. Sorensen E. Arias SSC Pacific R. Pitt L. Talebi...demonstration/validation project to assess the use of the urban stormwater model Windows Source Loading and Management Model (WinSLAMM) to characterize
Characterization of Plasma Discharges in a High-Field Magnetic Tandem Mirror
NASA Technical Reports Server (NTRS)
Chang-Diaz, Franklin R.
1998-01-01
High density magnetized plasma discharges in open-ended geometries, like Tandem Mirrors, have a variety of space applications. Chief among them is the production of variable Specific Impulse (I(sub sp)) and variable thrust in a magnetic nozzle. Our research group is pursuing the experimental characterization of such discharges in our high-field facility located at the Advanced Space Propulsion Laboratory (ASPL). These studies focus on identifying plasma stability criteria as functions of density, temperature and magnetic field strength. Plasma heating is accomplished by both Electron and Ion Cyclotron Resonance (ECR and ICR) at frequencies of 2-3 Ghz and 1-30 Mhz respectively, for both Hydrogen and Helium. Electron density and temperature has measured by movable Langmuir probes. Macroscopic plasma stability is being investigated in ongoing research.
NASA Astrophysics Data System (ADS)
Boisvert, J.-S.; Stafford, L.; Naudé, N.; Margot, J.; Massines, F.
2018-03-01
Diffuse dielectric barrier discharges are generated over a very wide range of frequencies. According to the targeted frequency, the glow, Townsend-like, hybrid, Ω and RF-α modes are sustained. In this paper, the electrical characterization of the discharge cell together with an electrical model are used to estimate the electron density from current and voltage measurements for excitation frequencies ranging from 50 kHz to 15 MHz. The electron density is found to vary from 1014 to 1017 m-3 over this frequency range. In addition, a collisional-radiative model coupled with optical emission spectroscopy is used to evaluate the electron temperature (assuming Maxwellian electron energy distribution function) in the same conditions. The time and space-averaged electron temperature is found to be about 0.3 eV in both the low-frequency and high-frequency ranges. However, in the medium-frequency range, it reaches almost twice this value as the discharge is in the hybrid mode. The hybrid mode is similar to the atmospheric-pressure glow discharge usually observed in helium DBDs at low frequency with the major difference being that the plasma is continuously sustained and is characterized by a higher power density.
Large scale Tesla coil guided discharges initiated by femtosecond laser filamentation in air
NASA Astrophysics Data System (ADS)
Arantchouk, L.; Point, G.; Brelet, Y.; Prade, B.; Carbonnel, J.; André, Y.-B.; Mysyrowicz, A.; Houard, A.
2014-07-01
The guiding of meter scale electric discharges produced in air by a Tesla coil is realized in laboratory using a focused terawatt laser pulse undergoing filamentation. The influence of the focus position, the laser arrival time, or the gap length is studied to determine the best conditions for efficient laser guiding. Discharge parameters such as delay, jitter, and resistance are characterized. An increase of the discharge length by a factor 5 has been achieved with the laser filaments, corresponding to a mean breakdown field of 2 kV/cm for a 1.8 m gap length. Consecutive guided discharges at a repetition rate of 10 Hz are also reported.
NASA/GSFC Testing of Li-Ion Cells: Update
NASA Technical Reports Server (NTRS)
Vaidyanathan, Hari; Rao, Gopalakrishna M.
2001-01-01
This viewgraph paper presents a report on the ongoing testing of Lithium Ion (Li-Ion) cells. Characterizes cells according to capacity, self-discharge, and mid-discharge voltage. Determines the cycling performance of Li-Ion cells as batteries according to number of cycles, charge voltage, and temperature.
Treatment of perforated giant gastric ulcer in an emergency setting.
Kumar, Pradeep; Khan, Hosni Mubarak; Hasanrabba, Safarulla
2014-01-27
To study and assess clinical outcomes of various modes of treatment for perforated giant gastric ulcer in an emergency setting. From May 2010 to February 2013, 20 cases of perforated giant gastric ulcer (> 2 cm) were operated on in an emergency setting. All the patients presented with features of peritonitis and were resuscitated aggressively before taking for surgery. In the first 4 cases, primary closure was done after taking a biopsy and among these, the 3(rd) case also underwent partial distal gastrectomy and gastrojejunostomy and the 4(th) case underwent a radical subtotal gastrectomy with D2 lymphadenectomy and gastrojejunostomy for malignancy. All the remaining 16 cases underwent partial distal gastrectomy and gastrojejunostomy. Among the first 4 cases, 2 had an uneventful recovery and were discharged on the 6(th) postoperative day. The 3(rd) and 4(th) patients developed gastric fistula, leading to prolonged hospitalization. For the 3(rd) patient, conservative management was tried for 1 wk, followed by partial distal gastrectomy and gastrojejunostomy, and he was discharged on the 20(th) day after admission, while the 4(th) patient underwent a radical subtotal gastrectomy with D2 lymphadenectomy and gastrojejunostomy. Postoperatively, he developed adult respiratory distress syndrome, multiorgan dysfunction syndrome and expired on the 3(rd) postoperative day of the second surgery. All the remaining 16 patients underwent partial distal gastrectomy and gastrojejunostomy and recovered well. Among these, 4 of them were malignant and the remaining were benign ulcers. All had an uneventful recovery. The percentage of malignancy in our series was 30% (6 out of 20 cases). In our study, 86% had an uneventful recovery, complications were seen in about 10%, and mortality was about 5%. In giant gastric ulcer, the chances of malignancy and leak after primary closure are high. So, we feel that partial distal gastrectomy and gastrojejunostomy is better.
Dahlen, Hannah G; Homer, Caroline S E
2010-03-01
There is a belief amongst midwives that Asian women are less likely to breastfeed compared to non-Asian women. The aim of this research was to compare the infant feeding decisions of Asian and non-Asian women on discharge from two Sydney hospitals, and at 6 and 12 weeks following birth. 235 Asian and 462 non-Asian first time mothers. A secondary analysis was undertaken into data from a randomised clinical trial of a perineal management technique (perineal warm packs). Simple descriptive statistics were used for analysis and Chi-square and logistic regression was used to examine differences between women from Asian and non-Asian backgrounds. Compared with non-Asian women, Asian women were no less likely to exclusively breastfeed on discharge from hospital (83% vs. 87%, OR 0.7, 95% CI 0.4-1.2), at 6 weeks (60% vs. 61%, OR 1, 95% CI 0.7-1.4) or 12 weeks postpartum (51% vs. 56%, OR 0.8, 95% CI 0.6-1.2). They were, however, significantly more likely to be partially breastfeeding on discharge from hospital (10% vs. 2%, OR 5.3, 95% CI 2.3-12.4), at 6 weeks (22% vs. 11%, OR 1.9, 95% CI 1.2-3.2) and 12 weeks postpartum (17% vs. 8%, OR 2.2, 95% CI 1.2-3.9). Asian women were more likely than non-Asian women to be giving their baby some breast milk at 6 and 12 weeks postpartum when partial breastfeeding was taken into account. This contradicts popular beliefs amongst midwives regarding the infant feeding practices of Asian women. Further research into this important issue is needed in order to improve breastfeeding support for women from different cultural backgrounds. The issue of causes of, and variations in, the levels of partial breastfeeding between different ethnic groups needs more investigation. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.
21 CFR 175.260 - Partial phosphoric acid esters of polyester resins.
Code of Federal Regulations, 2014 CFR
2014-04-01
... section, partial phosphoric acid esters of polyester resins are prepared by the reaction of trimellitic anhydride with 2,2-dimethyl-1,3-propanediol followed by reaction of the resin thus produced with phosphoric... characterizing the type of food and under the conditions of time and temperature characterizing the conditions of...
Kim, Grace J; Hinojosa, Jim; Rao, Ashwini K; Batavia, Mitchell; O'Dell, Michael W
2017-10-01
To compare the long-term effects of external focus (EF) and internal focus (IF) of attention after 4 weeks of arm training. Randomized, repeated-measures, mixed analysis of variance. Outpatient clinic. Individuals with stroke and moderate-to-severe arm impairment living in the community (N=33; withdrawals: n=3). Four-week arm training protocol on a robotic device (12 sessions). Joint independence, Fugl-Meyer Assessment, and Wolf Motor Function Test measured at baseline, discharge, and 4-week follow-up. There were no between-group effects for attentional focus. Participants in both groups improved significantly on all outcome measures from baseline to discharge and maintained those changes at 4-week follow-up regardless of group assignment (joint independence EF condition: F 1.6,45.4 =17.74; P<.0005; partial η 2 =.39; joint independence IF condition: F 2,56 =18.66; P<.0005; partial η 2 =.40; Fugl-Meyer Assessment: F 2,56 =27.83; P<.0005; partial η 2 =.50; Wolf Motor Function Test: F 2,56 =14.05; P<.0005; partial η 2 =.35). There were no differences in retention of motor skills between EF and IF participants 4 weeks after arm training, suggesting that individuals with moderate-to-severe arm impairment may not experience the advantages of an EF found in healthy individuals. Attentional focus is most likely not an active ingredient for retention of trained motor skills for individuals with moderate-to-severe arm impairment, whereas dosage and intensity of practice appear to be pivotal. Future studies should investigate the long-term effects of attentional focus for individuals with mild arm impairment. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Iwamoto, Masayoshi; Kawada, Kenji; Hida, Koya; Hasegawa, Suguru; Sakai, Yoshiharu
2017-08-01
Anastomotic leakage (AL) is one of the most dreadful postoperative complications because it can result in increased morbidity and mortality as well as poorer long-term prognosis. Although most studies of AL limited their investigation time to a period of 30 days postoperatively, only a few studies have shown that AL can occur after that period. Here, we report four patients of rectal cancer with delayed AL following laparoscopic intersphincteric resection (ISR) and conduct a literature review on delayed AL. Case 1 was a 67-year-old male who underwent laparoscopic partial ISR in July 2009. Although the patient was asymptomatic, an anastomotic-urethral fistula was observed 57 months after ISR. Case 2 was a 44-year-old female who underwent laparoscopic partial ISR in July 2008. She presented with discharge of gas and feces from her vagina, and an anastomotic-vaginal fistula was observed 14 months after ISR. Case 3 was a 74-year-old man who underwent laparoscopic partial ISR in August 2007. He presented with pneumaturia and fecaluria, and an anastomotic-urethral fistula was observed 4 months after ISR. Case 4 was a 68-year-old woman who underwent laparoscopic subtotal ISR for rectal cancer in February 2013 and partial hepatic resection for liver metastases in March 2013. She presented with anal pain and purulent perineal discharge, and an anastomotic-perineal fistula was observed 9 months after ISR. All four cases presented with fistula formation and required reoperation (establishment of a diverting ileostomy). Since delayed AL is not a rare postoperative complication, surgeons need to provide long-term follow-up and remain alert to the possible development of delayed AL.
The effect of a combined low-pressure gas discharge on metal surfaces
NASA Astrophysics Data System (ADS)
Brzhozovskii, B.; Brovkova, M.; Gestrin, S.; Martynov, V.; Zinina, E.
2018-04-01
The properties and effects of a combined gas discharge, obtained by superimposing ultrahigh-frequency electromagnetic and electrostatic fields on the surface of metal products, have been studied. Estimates for the main physical properties characterizing the discharge have been obtained. The paper shows that the properties of a combined discharge essentially depend on the sign of the constant electric potential of the workpiece. In the case of a positive potential, there is a substantial hardening of the metal surface layer. Blanket coating formation, which is a nanocomposite two-phase structure, has been recorded.
NASA Astrophysics Data System (ADS)
He, Yuchen; Satoshi, Uehara; Hidemasa, Takana; Hideya, Nishiyama
2016-09-01
A zero-dimensional model to simulate a nano-pulse-discharged bubble in water was developed. The model consists of gas and liquid phases corresponding to the inside and outside of the bubble, respectively. The diffusions of chemical species from the gas to the liquid phase through the bubble interface was also investigated. The initial gas is Ar, but includes a little H2O and O2 in the bubble. The time evolution of the OH concentration in the liquid phase was mainly investigated as an important species for water treatment. It was shown that OH was generated in the bubble and then diffused into the liquid. With the application of a continuous nano-pulse discharge, more OH radicals were generated as the frequency increased at a low voltage for a given power consumption. supported partially by Japan Society for the Promotion of Science (JSPS) KAKENHI (No. 26249015)
NASA Astrophysics Data System (ADS)
Matsuta, Hideyuki
2017-06-01
The coherent forward scattering (CFS) spectra of O I 844.6 nm and Ar I 842.5 nm lines in a radio frequency (RF) glow discharge were measured using a CFS spectrometer that functions in the Faraday configuration with permanent double-ring magnets and a diode-laser source. A significant change in the CFS spectrum of the Ar I 842.5 nm line was observed when the partial pressures of argon in a Hesbnd Ar RF glow discharge were changed . Based on the theoretical calculations of the CFS spectra performed using Faraday functions, a comparison between the observed and calculated spectra was performed. The CFS line profile of O I 844.6 nm and changes in the Ar I 842.5 nm CFS spectrum are explained by theoretical calculations.
Wicklein, Shaun M.; Powell, Eugene D.; Guyer, Joel R.; Owens, Joseph A.
2006-01-01
Water-resources data for the 2005 water year for Virginia includes records of stage, discharge, and water quality of streams and stage, contents, and water quality of lakes and reservoirs. This volume contains records for water discharge at 172 gaging stations; stage only at 2 gaging stations; elevation at 2 reservoirs and 2 tide gages; contents at 1 reservoir, and water quality at 25 gaging stations. Also included are data for 50 crest-stage partial-record stations. Locations of these sites are shown on figures 4A-B and 5A-B. Miscellaneous hydrologic data were collected at 128 measuring sites and 19 water-quality sampling sites not involved in the systematic data-collection program. The data in this report represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in Virginia.
Water Resources Data--Kansas, Water Year 2003
Putnam, J.E.; Schneider, D.R.
2004-01-01
Water-resources data for the 2003 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 148 complete-record gaging stations; elevation and contents at 17 lakes and reservoirs; water-quality records at 2 precipitation stations, water-level data at 12 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 11 gaging stations and 2 lakes with water-quality monitors. Also included are discharge data for 27 high-flow partial-record stations, miscellaneous onsite water-quality data collected at 138 stations, and suspended-sediment concentration for 11 stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.
Mathematical physics approaches to lightning discharge problems
NASA Technical Reports Server (NTRS)
Kyrala, A.
1985-01-01
Mathematical physics arguments useful for lightning discharge and generation problems are pursued. A soliton Ansatz for the lightning stroke is treated including a charge generation term which is the ultimate source for the phenomena. Equations are established for a partially ionized plasma inding the effects of pressure, magnetic field, electric field, gravitation, viscosity, and temperature. From these equations is then derived the non-stationary generalized Ohm's Law essential for describing field/current density relationships in the horizon channel of the lightning stroke. The discharge initiation problem is discussed. It is argued that the ionization rate drives both the convective current and electric displacement current to increase exponentially. The statistical distributions of charge in the thundercloud preceding a lightning dischage are considered. The stability of the pre-lightning charge distributions and the use of Boltzmann relaxational equations to determine them are discussed along with a covered impedance path provided by the aircraft.
Progress in the characterization of diamond thin films prepared by a laser plasma discharge
NASA Astrophysics Data System (ADS)
Davanloo, F.; Juengerman, E. M.; Jander, D. R.; Lee, T. J.; Collins, C. B.
Progress in the characterization of diamond thin films produced by a unique laser plasma discharge source at practical growth rates of 0.7 micron/hr is reported. Optical properties, mass densities, and electrical resistivities of deposited films are given and their relationship to the power density of the laser at the graphite target is discussed. Examination of films with scanning tunneling microscopy show the clear prevalence of the structure recently predicted by Angus et al. (1990) in which sp3 clusters are bonded together with the carbon polytypes.
NASA Astrophysics Data System (ADS)
Kästner, K.; Hoitink, A. J. F.; Torfs, P. J. J. F.; Vermeulen, B.; Ningsih, N. S.; Pramulya, M.
2018-02-01
River discharge has to be monitored reliably for effective water management. As river discharge cannot be measured directly, it is usually inferred from the water level. This practice is unreliable at places where the relation between water level and flow velocity is ambiguous. In such a case, the continuous measurement of the flow velocity can improve the discharge prediction. The emergence of horizontal acoustic Doppler current profilers (HADCPs) has made it possible to continuously measure the flow velocity. However, the profiling range of HADCPs is limited, so that a single instrument can only partially cover a wide cross section. The total discharge still has to be determined with a model. While the limitations of rating curves are well understood, there is not yet a comprehensive theory to assess the accuracy of discharge predicted from velocity measurements. Such a theory is necessary to discriminate which factors influence the measurements, and to improve instrument deployment as well as discharge prediction. This paper presents a generic method to assess the uncertainty of discharge predicted from range-limited velocity profiles. The theory shows that a major source of error is the variation of the ratio between the local and cross-section-averaged velocity. This variation is large near the banks, where HADCPs are usually deployed and can limit the advantage gained from the velocity measurement. We apply our theory at two gauging stations situated in the Kapuas River, Indonesia. We find that at one of the two stations the index velocity does not outperform a simple rating curve.
Microelectrode-assisted low-voltage atmospheric pressure glow discharge in air
NASA Astrophysics Data System (ADS)
Liu, Wenzheng; Zhao, Shuai; Niu, Jiangqi; Chai, Maolin
2017-09-01
During the process of discharge, appropriately changing the paths corresponding to electric field lines and the field strength distribution along these paths, as well as increasing the number of initial electrons, can effectively enhance the uniformity of discharge and inhibit the formation of filamentary discharge. A method is proposed that uses a microelectrode to initiate the macroscopic discharge phenomenon. An asymmetric structure was designed comprising a single electrode of carbon fiber; this electrode structure is of helical-contact type. Benefitting from the special electric field distribution and the microdischarge process, a three-dimensional atmospheric pressure glow discharge was achieved in air, characterized by low discharge voltage, low energy consumption, good diffusion performance, and less ozone generation. The plasma studied is uniform and stable with good diffusion characteristics and low levels of contaminants and hence has potential applications in the field of air purification.
NASA Astrophysics Data System (ADS)
Huang, Q.; Long, D.; Du, M.; Hong, Y.
2017-12-01
River discharge is among the most important hydrological variables of hydrologists' concern, as it links drinking water supply, irrigation, and flood forecast together. Despite its importance, there are extremely limited gauging stations across most of alpine regions such as the Tibetan Plateau (TP) known as Asia's water towers. Use of remote sensing combined with partial in situ discharge measurements is a promising way of retrieving river discharge over ungauged or poorly gauged basins. Successful discharge estimation depends largely on accurate water width (area) and water level, but it is challenging to obtain these variables for alpine regions from a single satellite platform due to narrow river channels, complex terrain, and limited observations. Here, we used high-spatial-resolution images from Landsat series to derive water area, and satellite altimetry (Jason 2) to derive water level for the Upper Brahmaputra River (UBR) in the TP with narrow river width (less than 400 m in most occasions). We performed waveform retracking using a 50% Threshold and Ice-1 Combined algorithm (TIC) developed in this study to obtain accurate water level measurements. The discharge was estimated well using a range of derived formulas including the power function between water level and discharge, and that between water area and discharge suitable for the triangular cross-section around the Nuxia gauging station in the UBR. Results showed that the power function using Jason 2-derived water levels after performing waveform retracking performed best, showing an overall NSE value of 0.92. The proposed approach for remotely sensed river discharge is effective in the UBR and possibly other alpine rivers globally.
Three distinct modes in a surface micro-discharge in atmospheric pressure He + N{sub 2} mixtures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Dong; Liu, Dingxin, E-mail: liudingxin@mail.xjtu.edu.cn; He, Tongtong
2015-12-15
A surface micro-discharge in atmospheric pressure He + N{sub 2} mixtures is studied in this paper with an emphasis on the discharge modes. With the N{sub 2} admixture increasing from 0.1% to 20%, the discharge evolves from a spatially diffuse mode to a filamentary mode during positive half-cycles of the applied voltage. However during the negative half-cycles, an additional patterned mode emerges between the diffuse and the filamentary modes, which has not been reported before to exist in surface micro-discharges. In the diffuse and patterned modes, the plasmas cover almost the entirety of the mesh area during one cycle after plasma ignitionmore » in all mesh elements, and the discharge power increases linearly with the applied voltage. In contrast, plasma coverage of the mesh area is only partial in the filamentary mode and the plasma is more unstable with the discharge power increasing exponentially with the applied voltage. As the surface micro-discharge evolves through the three modes, the density of excited species changes significantly, for instance, the density of N{sub 2}{sup +}(B) drops by ∼20-fold from [N{sub 2}] = 0.2% to 20%. The N{sub 2}{sup +}(B) is predicted to be generated mainly through successive processes of Penning ionization by helium metastables and electron-impact excitation of N{sub 2}{sup +}(X), the latter is most responsible for the density decrease of N{sub 2}{sup +}(B) because much more N{sub 2}{sup +}(X) is converted to N{sub 4}{sup +}(X) as the increase of N{sub 2} fraction. Also, the electron density and electron temperature decrease with the discharge mode transition.« less
Characterization of high power impulse magnetron sputtering discharges
NASA Astrophysics Data System (ADS)
Hala, Matej
Paper I: In the first paper, we present a new approach in the characterization of the high power pulsed magnetron sputtering (HiPIMS) discharge evolution—time- and species-resolved plasma imaging—employing a set of band-pass optical interference filters suitable for the isolation of the emission originating from different species populating the plasma. We demonstrate that the introduction of such filters can be used to distinguish different phases of the discharge, and to visualize numerous plasma effects including background gas excitations during the discharge ignition, gas shock waves, and expansion of metal-rich plasmas. In particular, the application of this technique is shown on the diagnostics of the 200 µs long non-reactive HiPIMS discharges using a Cr target. Paper II: In order to gain further information about the dynamics of reactive HiPIMS discharges, both fast plasma imaging and time- and space-resolved optical emission spectroscopy (OES) are used for a systematic investigation of the 200 µs long HiPIMS pulses operated in Ar, N2 and N 2/Ar mixtures and at various pressures. It is observed that the dense metal plasma created next to the target propagates in the reactor at a speed ranging from 0.7 to 3.5 km s-1, depending on the working gas composition and the pressure. In fact, it increases with higher N 2 concentration and with lower pressure. The visible form of the propagating plasma wave changes from a hemispherical shape in Ar to a drop-like shape extending far from the target with increasing N2 concentration, owing to the significant emission from molecular N2. Interestingly, the evidence of the target self-sputtering is found for all investigated conditions, including pure N2 atmosphere. Paper III: Here, we report on the time- and species-resolved plasma imaging analysis of the dynamics of the 200 µs long HiPIMS discharges above a Cr target ignited in pure O2. It is shown that the discharge emission is dominated solely by neutral and ionized oxygen, since the monitored discharge is operated above a fully poisoned (oxidized) target from which only a minimum of Cr is sputtered. No signs of self-sputtering have been detected, in contrast to the discharges in Ar, N2 and N2/Ar mixtures previously investigated. Paper IV: In the fourth paper, we study different power management approaches in HiPIMS and MPPMS and their effects on the pulsed discharge evolution, plasma composition, and metal ionization estimated by OES. It is shown that HiPIMS is the only technique that enables the discharge operation in self-sputtering mode within the investigated range of applied powers, resulting in a significantly higher ionization of the sputtered metal than that reached with MPPMS. In contrast to HiPIMS, MPPMS provides a higher versatility in adjusting the pulse shape and pulse length. This feature can be particularly beneficial, for instance, in the discharge ignition. Nb coatings prepared by HiPIMS and MPPMS have very similar deposition rates that are lower than in DCMS. All films prepared at p = 1Pa possess a dense columnar structure. Coatings deposited by the two high power pulsed discharges exhibit higher compressive stress and larger out-of-plane lattice spacing than those prepared by DC sputtering under comparable conditions. At higher pressure, p = 2Pa, DCMS-grown films show a tensile stress due to a porous microstructure, while films prepared by HiPIMS and MPPMS are dense and in compression, most probably due to the substantial ion bombardment. Paper V: In the last paper, we analyze the behavior of the HiPIMS, MPPMS and DCMS discharges in reactive O2/Ar gas mixtures and evaluate the characteristics of the fabricated NbOx films. We demonstrate that the surface metal oxides can be effectively sputter-eroded from the target during both HiPIMS and MPPMS pulses, and that sputtering from a partially oxide-free target is possible even at high oxygen concentrations. This results in a hysteresisfree deposition process which allows one to prepare optically transparent b2O5 coatings at a high growth rate without the need of feedback control commonly used in reactive DCMS. Nb2O 5 coatings prepared by both reactive high power pulsed discharges exhibited a high index of refraction, a low extinction coefficient, a near-zero internal stress, and high hardness and Young's modulus. The HiPIMS-deposited coatings showed the highest deposition rate and the highest index of refraction. The latter observation was related to the higher film density. In comparison, MPPMS exhibited the highest power-normalized deposition rate among the three investigated deposition techniques, possibly due to the longer period that is available for the gradual target cleaning. (Abstract shortened by UMI.).
Wang, Lutang; Fang, Nian; Wu, Chunxu; Qin, Haijuan; Huang, Zhaoming
2014-01-01
A novel fiber-optic acoustic sensor using an erbium-doped fiber amplifier (EDFA)-based fiber ring laser and a balanced Sagnac interferometer for acoustic sensing of the partial discharge (PD) in power transformers is proposed and demonstrated. As a technical background, an experimental investigation on how the variations of the fiber birefringence affect the sensor performances was carried out, and the results are discussed. The operation principles are described, and the relevant formulas are derived. The analytical results show that an EDFA-based fiber ring laser operating in chaotic mode can provide a degree of polarization (DOP) tunable light beam for effectively suppressing polarization fading noises. The balanced Sagnac interferometer can eliminate command intensity noises and enhance the signal-to-noise ratio (SNR). Furthermore, it inherently operates at the quadrature point of the response curve without any active stabilizations. Several experiments are conducted for evaluating the performances of the sensor system, as well as for investigating the ability of the detection of high-frequency acoustic emission signals. The experimental results demonstrate that the DOP of the laser beam can be continuously tuned from 0.2% to 100%, and the power fluctuation in the whole DOP tuning range is less than 0.05 dBm. A high-frequency response up to 300 kHz is reached, and the high sensing sensitivity for detections of weak corona discharges, as well as partial discharges also is verified. PMID:24824371
Dong, Xingchen; Zhang, Xiaoxing; Wu, Xiaoqing; Cui, Hao; Chen, Dachang
2016-01-01
Latent insulation defects introduced in manufacturing process of gas-insulated switchgears can lead to partial discharge during long-time operation, even to insulation fault if partial discharge develops further. Monitoring of decomposed components of SF6, insulating medium of gas-insulated switchgear, is a feasible method of early-warning to avoid the occurrence of sudden fault. Polyaniline thin-film with protonic acid deposited possesses wide application prospects in the gas-sensing field. Polyaniline thin-film sensors with only sulfosalicylic acid deposited and with both hydrochloric acid and sulfosalicylic acid deposited were prepared by chemical oxidative polymerization method. Gas-sensing experiment was carried out to test properties of new sensors when exposed to H2S and SO2, two decomposed products of SF6 under discharge. The gas-sensing properties of these two sensors were compared with that of a hydrochloric acid deposited sensor. Results show that the hydrochloric acid and sulfosalicylic acid deposited polyaniline thin-film sensor shows the most outstanding sensitivity and selectivity to H2S and SO2 when concentration of gases range from 10 to 100 μL/L, with sensitivity changing linearly with concentration of gases. The sensor also possesses excellent long-time and thermal stability. This research lays the foundation for preparing practical gas-sensing devices to detect H2S and SO2 in gas-insulated switchgears at room temperature. PMID:27834895
Numajiri, Toshiaki; Nakatsukasa, Katsuhiko; Sakaguchi, Koichi; Taguchi, Tetsuya
2017-01-01
Purpose The pedicled, descending-branch muscle-sparing latissimus dorsi (MSLD) flap has been widely used for breast reconstruction following total mastectomy. However, the superiority of the MSLD flap compared to the conventional latissimus dorsi (CLD) flap in preventing seroma formation has not been demonstrated. This study compares the morbidities related to seroma formation following pedicled MSLD flap and CLD flap breast reconstruction. Methods A total of 15 women who underwent partial mastectomy and immediate partial breast reconstruction with MSLD flaps were compared with 15 women under identical conditions with CLD flap breast reconstruction. The medical records were reviewed for both complications and demographic data. The authors compared morbidity, including donor-site seroma, total volume of drain discharge, indwelling period of drainage, and length of hospital stay following both MSLD flap and CLD flap breast reconstruction. Results The demographic data of the 2 groups were not significantly different. Donor-site seroma occurred in 2 MSLD patients (13.3%) and in 6 CLD patients (40.0%). The total volume of the drain discharge and the indwelling period of drainage at donor site were significantly lower in the MSLD group. The length of hospital stay was significantly shorter (by approximately a day and a half) for the MSLD group. Conclusion The MSLD flap, with its low complication rate and associated minimal functional and aesthetic deficits at the donor site, may be a useful option for small breast reconstruction if earlier discharge from hospital is demanded. PMID:28932726
Sowa, Yoshihiro; Numajiri, Toshiaki; Nakatsukasa, Katsuhiko; Sakaguchi, Koichi; Taguchi, Tetsuya
2017-09-01
The pedicled, descending-branch muscle-sparing latissimus dorsi (MSLD) flap has been widely used for breast reconstruction following total mastectomy. However, the superiority of the MSLD flap compared to the conventional latissimus dorsi (CLD) flap in preventing seroma formation has not been demonstrated. This study compares the morbidities related to seroma formation following pedicled MSLD flap and CLD flap breast reconstruction. A total of 15 women who underwent partial mastectomy and immediate partial breast reconstruction with MSLD flaps were compared with 15 women under identical conditions with CLD flap breast reconstruction. The medical records were reviewed for both complications and demographic data. The authors compared morbidity, including donor-site seroma, total volume of drain discharge, indwelling period of drainage, and length of hospital stay following both MSLD flap and CLD flap breast reconstruction. The demographic data of the 2 groups were not significantly different. Donor-site seroma occurred in 2 MSLD patients (13.3%) and in 6 CLD patients (40.0%). The total volume of the drain discharge and the indwelling period of drainage at donor site were significantly lower in the MSLD group. The length of hospital stay was significantly shorter (by approximately a day and a half) for the MSLD group. The MSLD flap, with its low complication rate and associated minimal functional and aesthetic deficits at the donor site, may be a useful option for small breast reconstruction if earlier discharge from hospital is demanded.
Pocket nickel cadmium cell and battery evaluation
NASA Technical Reports Server (NTRS)
Lear, J. W.
1980-01-01
The Nickel Cadmium 129-ampere hour cell was tested in order to characterize the cell under controlled conditions. Results of charge characterization and discharge characterization are reported. Ampere hour efficiency, open circuit stand, and cycle life operation results are included. The battery is briefly described.
Effects of Stormwater Pipe Size and Rainfall on Sediment and Nutrients Delivered to a Coastal Bayou
Pollutants discharged from stormwater pipes can cause water quality and ecosystem problems in coastal bayous. A study was conducted to characterize sediment and nutrients discharged by small and large (, 20 cm and .20 cm in internal diameters, respectively) pipes under different ...
Two approaches for estimating discharge on ungauged basins in Oregon, USA
Detailed information on the hydrologic behavior of streams is available for only a small proportion of all streams. Even in cases where discharge has been monitored, these measurements may not be available for a sufficiently long period to characterize the full behavior of a str...
Dynamics of laser-guided alternating current high voltage discharges
NASA Astrophysics Data System (ADS)
Daigle, J.-F.; Théberge, F.; Lassonde, P.; Kieffer, J.-C.; Fujii, T.; Fortin, J.; Châteauneuf, M.; Dubois, J.
2013-10-01
The dynamics of laser-guided alternating current high voltage discharges are characterized using a streak camera. Laser filaments were used to trigger and guide the discharges produced by a commercial Tesla coil. The streaking images revealed that the dynamics of the guided alternating current high voltage corona are different from that of a direct current source. The measured effective corona velocity and the absence of leader streamers confirmed that it evolves in a pure leader regime.
Performance of a dual anode nickel-hydrogen cell
NASA Technical Reports Server (NTRS)
Gahn, Randall F.
1991-01-01
An experimental study was conducted to characterize the voltage performance of a nickel hydrogen cell containing a hydrogen electrode on both sides of the nickel electrode. The dual anode cell was compared with a convenient single anode cell using the same nickel electrode. Higher discharge voltages and lower charge voltages were obtained with the dual anode cell during constant current discharges to 10C, pulse discharges to 8C, and polarization measurements at 50 percent of charge.
Simulated Beam Extraction Performance Characterization of a 50-cm Ion Thruster Discharge
NASA Technical Reports Server (NTRS)
Foster, John E.; Hubble, Aimee; Nowak-Gucker, Sarah; Davis, Chris; Peterson, Peter; Viges, Eric; Chen, Dave
2013-01-01
A 50 cm ion thruster is being developed to operate at >65 percent total efficiency at 11 kW, 2700 s Isp and over 25 kW, 4500 s Isp at a total efficiency of >75 percent. The engine is being developed to address the need for a multimode system that can provide a range of thrust-to- power to service national and commercial near-earth onboard propulsion needs such as station-keeping and orbit transfer. Operating characteristics of the 50 cm ion thruster were measured under simulated beam extraction. The discharge current distribution at the various magnet rings was measured over a range of operating conditions. The relationship between the anode current distribution and the resulting plasma uniformity and ion flux measured at the thruster exit plane is discussed. The thermal envelope will also be investigated through the monitoring of magnet temperatures over the range of discharge powers investigated. Discharge losses as a function of propellant utilization was also characterized at multiple simulated beam currents. Bulk plasma conditions such as electron temperature and electron density near engine centerline was measured over a range of operating conditions using an internal Langmuir probe. Sensitivity of discharge performance to chamber length is also discussed. This data acquired from this discharge study will be used in the refinement of a throttle table in anticipation for eventual beam extraction testing.
Sediment traps with guiding channel and hybrid check dams improve controlled sediment retention
NASA Astrophysics Data System (ADS)
Schwindt, Sebastian; Franca, Mário J.; Reffo, Alessandro; Schleiss, Anton J.
2018-03-01
Sediment traps with partially open check dams are crucial elements for flood protection in alpine regions. The trapping of sediment is necessary when intense sediment transport occurs during floods that may endanger urban areas at downstream river reaches. In turn, the unwanted permanent trapping of sediment during small, non-hazardous floods can result in the ecological and morphological degradation of downstream reaches. This study experimentally analyses a novel concept for permeable sediment traps. For ensuring the sediment transfer up to small floods, a guiding channel implemented in the deposition area of a sediment trap was systematically studied. The bankfull discharge of the guiding channel corresponds to a dominant morphological discharge. At the downstream end of the guiding channel, a permeable barrier (check dam) triggers sediment retention and deposition. The permeable barrier consists of a bar screen for mechanical deposition control, superposed to a flow constriction for the hydraulic control. The barrier obstructs hazardous sediment transport for discharges that are higher than the bankfull discharge of the guiding channel without the risk of unwanted sediment flushing (massive self-cleaning).
Kramer, Megan E; Suskauer, Stacy J; Christensen, James R; DeMatt, Ellen J; Trovato, Melissa K; Salorio, Cynthia F; Slomine, Beth S
2013-01-01
To examine in a pilot cohort factors associated with functional outcome at discharge and 3-month follow-up after discharge from inpatient rehabilitation in children with severe traumatic brain injury (TBI) who entered rehabilitation with the lowest level of functional skills. Thirty-nine children and adolescents (3-18 years old) who sustained a severe TBI and had the lowest possible rating at rehabilitation admission on the Functional Independence Measure for Children (total score = 18). Retrospective review of data collected as part of routine clinical care. At discharge, 59% of the children were partially dependent for basic activities, while 41% remained dependent for basic activities. Initial Glasgow Coma Scale score, time to follow commands, and time from injury to rehabilitation admission were correlated with functional status at discharge. Time to follow commands and time from injury to rehabilitation admission were correlated with functional status at 3-month follow-up. Changes in functional status during the first few weeks of admission were associated with functional status at discharge and follow-up. Even children with the most severe brain injuries, who enter rehabilitation completely dependent for all daily activities, have the potential to make significant gains in functioning by discharge and in the following few months. Assessment of functional status early in the course of rehabilitation contributes to the ability to predict outcome from severe TBI.
Hypersonic Flow over a Cylinder with a Nanosecond-Pulse Electrical Discharge
2013-01-01
variation in bow-shock location, but no other factors, including rarefaction effects due to partial-slip walls, made an appreciable difference in the bow...heat transfer coefficient, Ch = 2 q/(ρ∞ u 3 ∞) along the surface of the cylinder at various times after the ns-DBD pulse. The curves were spanwise
Code of Federal Regulations, 2010 CFR
2010-04-01
...(b) must be added to the date of death value of the decedent's gross estate situated in the United... INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE AND GIFT TAXES ESTATE TAX; ESTATES... insure avoidance of liability for taxes and penalties only by demanding and receiving transfer...
Code of Federal Regulations, 2011 CFR
2011-04-01
...(b) must be added to the date of death value of the decedent's gross estate situated in the United... SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE AND GIFT TAXES ESTATE TAX; ESTATES OF DECEDENTS... insure avoidance of liability for taxes and penalties only by demanding and receiving transfer...
Code of Federal Regulations, 2013 CFR
2013-04-01
...(b) must be added to the date of death value of the decedent's gross estate situated in the United... INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE AND GIFT TAXES ESTATE TAX; ESTATES... insure avoidance of liability for taxes and penalties only by demanding and receiving transfer...
Code of Federal Regulations, 2012 CFR
2012-04-01
...(b) must be added to the date of death value of the decedent's gross estate situated in the United... INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE AND GIFT TAXES ESTATE TAX; ESTATES... insure avoidance of liability for taxes and penalties only by demanding and receiving transfer...
Code of Federal Regulations, 2014 CFR
2014-04-01
...(b) must be added to the date of death value of the decedent's gross estate situated in the United... SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE AND GIFT TAXES ESTATE TAX; ESTATES OF DECEDENTS... insure avoidance of liability for taxes and penalties only by demanding and receiving transfer...
Radionuclides in groundwater flow system understanding
NASA Astrophysics Data System (ADS)
Erőss, Anita; Csondor, Katalin; Horváth, Ákos; Mádl-Szőnyi, Judit; Surbeck, Heinz
2017-04-01
Using radionuclides is a novel approach to characterize fluids of groundwater flow systems and understand their mixing. Particularly, in regional discharge areas, where different order flow systems convey waters with different temperature, composition and redox-state to the discharge zone. Radium and uranium are redox-sensitive parameters, which causes fractionation along groundwater flow paths. Discharging waters of regional flow systems are characterized by elevated total dissolved solid content (TDS), temperature and by reducing conditions, and therefore with negligible uranium content, whereas local flow systems have lower TDS and temperature and represent oxidizing environments, and therefore their radium content is low. Due to the short transit time, radon may appear in local systems' discharge, where its source is the soil zone. However, our studies revealed the importance of FeOOH precipitates as local radon sources throughout the adsorption of radium transported by the thermal waters of regional flow systems. These precipitates can form either by direct oxidizing of thermal waters at discharge, or by mixing of waters with different redox state. Therefore elevated radon content often occurs in regional discharge areas as well. This study compares the results of geochemical studies in three thermal karst areas in Hungary, focusing on radionuclides as natural tracers. In the Buda Thermal Karst, the waters of the distinct discharge areas are characterized by different temperature and chemical composition. In the central discharge area both lukewarm (20-35°C, 770-980 mg/l TDS) and thermal waters (40-65°C, 800-1350 mg/l TDS), in the South only thermal water discharge (33-43°C, 1450-1700 mg/l TDS) occur. Radionuclides helped to identify mixing of fluids and to infer the temperature and chemical composition of the end members for the central discharge area. For the southern discharge zone mixing components could not be identified, which suggests different cave formation. The Bükk karst area is largely compartmentalized owing to the complex geological and structural build-up. Majority of the waters is low mineralized (TDS < 600 mg/l) regardless of their temperatures (8-77 °C). This may indicate deep but relatively fast/short flow paths. Thermal wells, characterized by higher TDS (1000-2500 mg/l) and radium content (400-1900 mBq/l), show the effects of hydrocarbon reservoir fluids. In the Villány Thermal Karst area the majority of the springs have lukewarm (20-26°C) waters with 712-930 mg/l TDS. Natural thermal water discharge (52-62°C, 1100 mg/l TDS) can be found only in Harkány. Here the highest concentration of radionuclides (226Ra: 230 mBq/l, 238+234U: 66 mBq/l, 222Rn: 43 Bq/l) suggest mixing of different flow systems. The results reflect the effect of different hydrogeological environments and flow regimes but similarities also could be revealed. The National Research, Development and Innovation Fund has provided financial support to the Villány project under the grant agreement no. PD 116227. The Bükk research was supported by the European Union and the State of Hungary, co-financed by the European Social Fund in the framework of TÁMOP-4.2.4.A/ 2-11/1-2012-0001 National Excellence Program. The Buda Thermal Karst research was funded by Shell International E&P and by the Hungarian Scientific Research Fund under the grant agreement no. NK 101356.
Cheng, Chui Ling
2016-08-03
Statistical models were developed to estimate natural streamflow under low-flow conditions for streams with existing streamflow data at measurement sites on the Islands of Kauaʻi, Oʻahu, Molokaʻi, Maui, and Hawaiʻi. Streamflow statistics used to describe the low-flow characteristics are flow-duration discharges that are equaled or exceeded between 50 and 95 percent of the time during the 30-year base period 1984–2013. Record-augmentation techniques were applied to develop statistical models relating concurrent streamflow data at the measurement sites and long-term data from nearby continuous-record streamflow-gaging stations that were in operation during the base period and were selected as index stations. Existing data and subsequent low-flow analyses of the available data help to identify streams in under-represented geographic areas and hydrogeologic settings where additional data collection is suggested.Low-flow duration discharges were estimated for 107 measurement sites (including long-term and short-term continuous-record streamflow-gaging stations, and partial-record stations) and 27 index stations. The adequacy of statistical models was evaluated with correlation coefficients and modified Nash-Sutcliff coefficients of efficiency, and a majority of the low-flow duration-discharge estimates are satisfactory based on these regression statistics.Molokaʻi and Hawaiʻi have the fewest number of measurement sites (that are not located on ephemeral stream reaches) at which flow-duration discharges were estimated, which can be partially explained by the limited number of index stations available on these islands that could be used for record augmentation. At measurement sites on some tributary streams, low-flow duration discharges could not be estimated because no adequate correlations could be developed with the index stations. These measurement sites are located on streams where duration-discharge estimates are available at long-term stations at other locations on the main stream channel to provide at least some definition of low-flow characteristics on that stream. In terms of general natural streamflow data availability, data are scarce in the leeward areas for all five islands as many leeward streams are dry or have minimal flow. Other under-represented areas include central Oʻahu, central Maui, and southeastern Maui.
Mwendwa, A C; Musoke, R N; Wamalwa, D C
2012-02-01
To determine the effect of partial Kangaroo Mother Care (KMC) on growth rates and duration of hospital stay of Low Birth Weight (LBW) infants. Unblinded, randomised clinical controlled trial. Kenyatta National Hospital, Nairobi, Kenya. Over a nine month period, consecutive recruitment of eligible LBW infants weighing 1000 g to 1750 g was done until a sample of 166 infants was reached. Kangaroo mother care was practised over an eight hour period per day for the intervention group while the controls remained in incubators or cots. Weight, head circumference, and mid upper arm circumference were monitored for all infants till discharge at 1800 g. Of the 166 infants recruited 157 were followed up to discharge. Baseline characteristics were similar for the two groups except for mother's age, with the KMC group mothers having a mean age of 26.5 years while the control group mothers had a mean age of 24 years, (p = 0.04). The KMC group had significantly higher growth rates as shown by the higher mean weight gain of 22.5 g/kg/day compared with 16.7g/kg/day for the control group, (p < 0.001); higher mean head circumference gain of 0.91 cm/week compared with 0.54 cm/week for the control group, (p < 0.001) and higher mean mid upper arm circumference gain of 0.76 cm/week compared with 0.48 cm/week for the control group, (p = 0.002). Although overall duration of stay was similar between study arms, when infants were stratified into those above or below 1500 g KMC infants' duration of stay was significantly shorter than those in regular care. Using logistic regression, KMCwas the strongest predictor formeanweight, meanhead circumference and mean MUAC gain while mother's age (older) was the strongest predictor for mean duration of stay with KMC being an independent predictor of duration of stay. Low birth weight infants in this cohort achieved rates of growth within the recommended intrauterine growth but babies managed using partial KMC grew faster and were thus discharged earlier than those on standard of care. Since partial KMC was beneficial, it should be fully implemented for all eligible infants.
Hopper apparatuses for processing a bulk solid, and related systems and methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westover, Tyler Lott; Ryan, John Chadron Benjamin; Matthews, Austin Colter
A hopper apparatus comprises a movable wall comprising opposing walls movably connected to a support assembly and oriented at acute angles relative to a central vertical axis of the support assembly, and movement control devices configured and positioned to move the opposing walls along the support assembly to control dimensions of a discharge outlet at least partially defined by converging ends of the opposing walls; a liner assembly comprising liner structures at least partially overlying inner surfaces of the opposing walls and configured to remain at least partially stationary relative to the opposing walls during movement of the opposing walls;more » and pressure sensors between the inner surfaces of opposing walls and portions of the liner structures thereover. A bulk solids processing system and a method of processing a bulk solid are also described.« less
Particle visualization in high-power impulse magnetron sputtering. I. 2D density mapping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britun, Nikolay, E-mail: nikolay.britun@umons.ac.be; Palmucci, Maria; Konstantinidis, Stephanos
2015-04-28
Time-resolved characterization of an Ar-Ti high-power impulse magnetron sputtering discharge has been performed. This paper deals with two-dimensional density mapping in the discharge volume obtained by laser-induced fluorescence imaging. The time-resolved density evolution of Ti neutrals, singly ionized Ti atoms (Ti{sup +}), and Ar metastable atoms (Ar{sup met}) in the area above the sputtered cathode is mapped for the first time in this type of discharges. The energetic characteristics of the discharge species are additionally studied by Doppler-shift laser-induced fluorescence imaging. The questions related to the propagation of both the neutral and ionized discharge particles, as well as to theirmore » spatial density distributions, are discussed.« less
Test methods and results of the 10-cell bipolar Ni-H2 battery
NASA Technical Reports Server (NTRS)
Cataldo, R.
1983-01-01
Characterization tests were carried out at three charge levels and four discharge levels. The "c' or capacity of the battery is designated at 6.5 ampere-hours. The recharge ampere-hours was the same for all test conditions, 6.5 A-H, regardless of the discharge capacity removed for any particular discharge rate. Less capacity can be removed at higher discharge rates to the same termination voltage, which was 0.50 volts for the weakest (lowest voltage) cell. The general trend of efficiencies increases as the charge rate increases as noted in results of the table included in the handout package. The data also indicate the efficiency increases as the discharge rate decreases. This is true; however, efficiencies at the discharge rates of c and 2c are penalized because these cycles received more overcharge than necessary.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durlin, R.R.; Schaffstall, W.P.
1997-02-01
This report, Volume, 2, includes record from the Susquehanna and Potomac River Basins. Specifically, it contains: (1) discharge records for 90 continuous-record streamflow-gaging stations and 41 partial-record stations; (2) elevation and contents record for 12 lakes and reservoirs; (3) water-quality records for 13 streamflow-gaging stations and 189 partial-record and project stations; and (4) water-level records for 25 network observation wells. Site locations are shown in figures throughout the report. Additional water data collected at various sites not involved in the systematic data-collection program are also presented.
State National Pollutant Discharge Elimination System (NPDES) Program Withdrawal Petitions
Search for pending and resolved NPDES withdrawal petitions by state, region, date, or keyword. Pending means EPA has received the petition and is working with the state and petitioner to resolve it. Withdrew petition means that the petitioner has withdrawn the petition they submitted. Resolved means that EPA has resolved the issues raised in the petition and has denied the petition. Partially resolved means that EPA has partially denied the petition by resolving some of the issues, while continuing to work with the state and petitioner on other pending issues. Program withdrawn would apply if, after conducting investigations, EPA withdrew a state's NPDES authority.
Doheny, Edward J.; Starsoneck, Roger J.; Striz, Elise A.; Mayer, Paul M.
2006-01-01
Stream restoration efforts have been ongoing in Maryland since the early 1990s. Physical stream restoration often involves replacement of lost sediments to elevate degraded streambeds, re-establishment of riffle-pool sequences along the channel profile, planting vegetation in riparian zones, and re-constructing channel banks, point bars, flood plains, and stream-meanders. The primary goal of many restoration efforts is to re-establish geomorphic stability of the stream channel and reduce erosive energy from urban runoff. Monitoring streams prior to and after restoration could help quantify other possible benefits of stream restoration, such as improved water quality and biota. This report presents general watershed characteristics associated with the Minebank Run watershed; a small, urban watershed in the south-central section of Baltimore County, Maryland that was physically restored in phases during 1999, 2004, and 2005. The physiography, geology, hydrology, land use, soils, and pre-restoration geomorphic setting of the unrestored stream channel are discussed. The report describes a reach of Minebank Run that was selected for the purpose of collecting several types of environmental data prior to restoration, including continuous-record and partial-record stage and streamflow data, precipitation, and ground-water levels. Examples of surface-water data that were collected in and near the study reach during water years 2002 through 2004, including continuous-record streamflow, partial-record stage and discharge, and precipitation, are described. These data were used in analyses of several characteristics of surface-water hydrology in the watershed, including (1) rainfall totals, storm duration, and intensity, (2) instantaneous peak discharge and daily mean discharge, (3) stage-discharge ratings, (4) hydraulic-geometry relations, (5) water-surface slope, (6) time of concentration, (7) flood frequency, (8) flood volume, and (9) rainfall-runoff relations. Several hydrologic characteristics that are typical of urban environments were quantified by these analyses. These include (1) large ratios of peak discharge to daily mean discharge as an indicator of flashiness, (2) consistent shifting of the stage-discharge rating over short periods of time that indicates instability of the stream channel, (3) analyses of hydraulic-geometry relations that indicate mean velocities of 11 feet per second or more while the flow is contained in the stream channel, (4) discharges that are 4 to 5 times larger in Minebank Run for corresponding flood frequency recurrence intervals than in Slade Run, which is a Piedmont watershed of similar size with smaller percentages of urban development, and (5) flood waves that can travel through the stream channel at a velocity of 412 feet per minute, or 6.9 feet per second.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durlin, R.R.; Schaffstall, W.P.
1993-08-01
Water resources data for the 1992 water year for Pennsylvania consist of records of discharge and water quality of streams; contents and elevations of lakes and reservoirs; and water levels and water quality of ground-water wells. The report, Volume 2, includes records from the Susquehanna and Potomac River basins. Specifically, it contains discharge records for 85 continuous-record streamflow-gaging stations and 38 partial-record stations; elevation and contents records for 13 lakes and reservoirs; water-quality records for 12 streamflow-gaging stations and 48 ungaged streamsites; and water-level records for 25 observation wells.
NASA Astrophysics Data System (ADS)
Orlov, A. M.; Yavtushenko, I. O.; Bodnarskii, D. S.
2013-03-01
The variation of the pressure of a gas phase activated by spark discharges between an aqueous electrolyte solution (liquid cathode) and a metallic electrode (anode) hanging over the solution is studied. A mathematical model of the proceeding reaction kinetics is constructed, and the variation of the partial pressures of all initial and produced components in the gas phase is calculated. Both the Faraday and non-Faraday mechanisms of gas component production from water are confirmed. It is found that a large overhanging drop responsible for additional supply of simultaneously produced H2 and O2 molecules forms rapidly at the end face of the anodically polarized electrode.
Active lamp pulse driver circuit. [optical pumping of laser media
NASA Technical Reports Server (NTRS)
Logan, K. E. (Inventor)
1983-01-01
A flashlamp drive circuit is described which uses an unsaturated transistor as a current mode switch to periodically subject a partially ionized gaseous laser excitation flashlamp to a stable, rectangular pulse of current from an incomplete discharge of an energy storage capacitor. A monostable multivibrator sets the pulse interval, initiating the pulse in response to a flash command by providing a reference voltage to a non-inverting terminal of a base drive amplifier; a tap on an emitter resistor provides a feedback signal sensitive to the current amplitude to an inverting terminal of amplifier, thereby controlling the pulse amplitude. The circuit drives the flashlamp to provide a squarewave current flashlamp discharge.
NASA Astrophysics Data System (ADS)
Meyer-Plath, Asmus; Beckert, Fabian; Tölle, Folke J.; Sturm, Heinz; Mülhaupt, Rolf
2016-02-01
A process was developed for graphite particle exfoliation in water to stably dispersed multi-layer graphene. It uses electrohydraulic shockwaves and the functionalizing effect of solution plasma discharges in water. The discharges were excited by 100 ns high voltage pulsing of graphite particle chains that bridge an electrode gap. The underwater discharges allow simultaneous exfoliation and chemical functionalization of graphite particles to partially oxidized multi-layer graphene. Exfoliation is caused by shockwaves that result from rapid evaporation of carbon and water to plasma-excited gas species. Depending on discharge energy and locus of ignition, the shockwaves cause stirring, erosion, exfoliation and/or expansion of graphite flakes. The process was optimized to produce long-term stable aqueous dispersions of multi-layer graphene from graphite in a single process step without requiring addition of intercalants, surfactants, binders or special solvents. A setup was developed that allows continuous production of aqueous dispersions of flake size-selected multi-layer graphenes. Due to the well-preserved sp2-carbon structure, thin films made from the dispersed graphene exhibited high electrical conductivity. Underwater plasma discharge processing exhibits high innovation potential for morphological and chemical modifications of carbonaceous materials and surfaces, especially for the generation of stable dispersions of two-dimensional, layered materials.
A parametric study on the PD pulses activity within micro-cavities
NASA Astrophysics Data System (ADS)
Ganjovi, Alireza A.
2016-03-01
A two-dimensional kinetic model has been used to parametric investigation of the spark-type partial discharge pulses inside the micro-cavities. The model is based on particle-in-cell methods with Monte Carlo Collision techniques for modeling of collisions. Secondary processes like photo-emission and cathode-emission are considered. The micro-cavity may be sandwiched between two metallic conductors or two dielectrics. The discharge within the micro-cavity is studied in conjunction with the external circuit. The model is used to successfully simulate the evolution of the discharge and yield useful information about the build-up of space charge within the micro-cavity and the consequent modification of the applied electric field. The phase-space scatter plots for electrons, positive, and negative ions are obtained in order to understand the manner in which discharge progresses over time. The rise-time and the magnitude of the discharge current pulse are obtained and are seen to be affected by micro-cavity dimensions, gas pressure within the micro-cavity, and the permittivity of surrounding dielectrics. The results have been compared with existing experimental, theoretical, and computational results, wherever possible. An attempt has been made to understand the nature of the variations in terms of the physical processes involved.
Optical Emission Characterization of High-Power Hall Thruster Wear
NASA Technical Reports Server (NTRS)
WIlliams, George J.; Kamhawi, Hani
2013-01-01
Optical emission spectroscopy is employed to correlate BN insulator erosion with high-power operation of the NASA 300M Hall-effect thruster. Actinometry leveraging excited xenon states is used to normalize the emission spectra of ground state boron as a function of thruster operating condition. Trends in the strength of the boron signal are correlated with thruster power, discharge voltage, discharge current and magnetic field strength. The boron signals are shown to trend with discharge current and show weak dependence on discharge voltage. The trends are consistent with data previously collected on the NASA 300M and NASA 457M thrusters but are different from conventional wisdom.
Liu, Pan; Han, Jiuhui; Guo, Xianwei; Ito, Yoshikazu; Yang, Chuchu; Ning, Shoucong; Fujita, Takeshi; Hirata, Akihiko; Chen, Mingwei
2018-02-16
Rechargeable non-aqueous lithium-oxygen batteries with a large theoretical capacity are emerging as a high-energy electrochemical device for sustainable energy strategy. Despite many efforts made to understand the fundamental Li-O 2 electrochemistry, the kinetic process of cathodic reactions, associated with the formation and decomposition of a solid Li 2 O 2 phase during charging and discharging, remains debate. Here we report direct visualization of the charge/discharge reactions on a gold cathode in a non-aqueous lithium-oxygen micro-battery using liquid-cell aberration-corrected scanning transmission electron microscopy (STEM) combining with synchronized electrochemical measurements. The real-time and real-space characterization by time-resolved STEM reveals the electrochemical correspondence of discharge/charge overpotentials to the nucleation, growth and decomposition of Li 2 O 2 at a constant current density. The nano-scale operando observations would enrich our knowledge on the underlying reaction mechanisms of lithium-oxygen batteries during round-trip discharging and charging and shed lights on the strategies in improving the performances of lithium-oxygen batteries by tailoring the cathodic reactions.
A time-resolved Langmuir double-probe method for the investigation of pulsed magnetron discharges
NASA Astrophysics Data System (ADS)
Welzel, Th.; Dunger, Th.; Kupfer, H.; Richter, F.
2004-12-01
Langmuir probes are important means for the characterization of plasma discharges. For measurements in plasmas used for the deposition of thin films, the Langmuir double probe is especially suited. With the increasing popularity of pulsed deposition discharges, there is also an increasing need for time-resolved characterization methods. For Langmuir probes, several single-probe approaches to time-resolved measurements are reported but very few for the double probe. We present a time-resolved Langmuir double-probe technique, which is applied to a pulsed magnetron discharge at several 100 kHz used for MgO deposition. The investigations show that a proper treatment of the current measurement is necessary to obtain reliable results. In doing so, a characteristic time dependence of the charge-carrier density during the "pulse on" time containing maximum values of almost 2•1011cm-3 was found. This characteristic time dependence varies with the pulse frequency and the duty cycle. A similar time dependence of the electron temperature is only observed when the probe is placed near the magnesium target.
Characterizing the SWOT discharge error budget on the Sacramento River, CA
NASA Astrophysics Data System (ADS)
Yoon, Y.; Durand, M. T.; Minear, J. T.; Smith, L.; Merry, C. J.
2013-12-01
The Surface Water and Ocean Topography (SWOT) is an upcoming satellite mission (2020 year) that will provide surface-water elevation and surface-water extent globally. One goal of SWOT is the estimation of river discharge directly from SWOT measurements. SWOT discharge uncertainty is due to two sources. First, SWOT cannot measure channel bathymetry and determine roughness coefficient data necessary for discharge calculations directly; these parameters must be estimated from the measurements or from a priori information. Second, SWOT measurement errors directly impact the discharge estimate accuracy. This study focuses on characterizing parameter and measurement uncertainties for SWOT river discharge estimation. A Bayesian Markov Chain Monte Carlo scheme is used to calculate parameter estimates, given the measurements of river height, slope and width, and mass and momentum constraints. The algorithm is evaluated using simulated both SWOT and AirSWOT (the airborne version of SWOT) observations over seven reaches (about 40 km) of the Sacramento River. The SWOT and AirSWOT observations are simulated by corrupting the ';true' HEC-RAS hydraulic modeling results with the instrument error. This experiment answers how unknown bathymetry and roughness coefficients affect the accuracy of the river discharge algorithm. From the experiment, the discharge error budget is almost completely dominated by unknown bathymetry and roughness; 81% of the variance error is explained by uncertainties in bathymetry and roughness. Second, we show how the errors in water surface, slope, and width observations influence the accuracy of discharge estimates. Indeed, there is a significant sensitivity to water surface, slope, and width errors due to the sensitivity of bathymetry and roughness to measurement errors. Increasing water-surface error above 10 cm leads to a corresponding sharper increase of errors in bathymetry and roughness. Increasing slope error above 1.5 cm/km leads to a significant degradation due to direct error in the discharge estimates. As the width error increases past 20%, the discharge error budget is dominated by the width error. Above two experiments are performed based on AirSWOT scenarios. In addition, we explore the sensitivity of the algorithm to the SWOT scenarios.
Papp, Joseph K.; Forster, Jason D.; Burke, Colin M.; ...
2017-02-27
We show that a common Li–O 2 battery cathode binder, poly(vinylidene fluoride) (PVDF), degrades in the presence of reduced oxygen species during Li–O 2 discharge when adventitious impurities are present. This degradation process forms products that exhibit Raman shifts (~1133 and 1525 cm –1) nearly identical to those reported to belong to lithium superoxide (LiO 2), complicating the identification of LiO 2 in Li–O 2 batteries. We show that these peaks are not observed when characterizing extracted discharged cathodes that employ poly(tetrafluoroethylene) (PTFE) as a binder, even when used to bind iridium-decorated reduced graphene oxide (Ir-rGO)-based cathodes similar to thosemore » that reportedly stabilize bulk LiO 2 formation. We confirm that for all extracted discharged cathodes on which the 1133 and 1525 cm –1 Raman shifts are observed, only a 2.0 e –/O 2 process is identified during the discharge, and lithium peroxide (Li 2O 2) is predominantly formed (along with typical parasitic side product formation). In conclusion, our results strongly suggest that bulk, stable LiO 2 formation via the 1 e –/O 2 process is not an active discharge reaction in Li–O 2 batteries.« less
Henderson, Rory; Day-Lewis, Frederick D.; Abarca, Elena; Harvey, Charles F.; Karam, Hanan N.; Liu, Lanbo; Lane, John W.
2010-01-01
Electrical resistivity imaging has been used in coastal settings to characterize fresh submarine groundwater discharge and the position of the freshwater/salt-water interface because of the relation of bulk electrical conductivity to pore-fluid conductivity, which in turn is a function of salinity. Interpretation of tomograms for hydrologic processes is complicated by inversion artifacts, uncertainty associated with survey geometry limitations, measurement errors, and choice of regularization method. Variation of seawater over tidal cycles poses unique challenges for inversion. The capabilities and limitations of resistivity imaging are presented for characterizing the distribution of freshwater and saltwater beneath a beach. The experimental results provide new insight into fresh submarine groundwater discharge at Waquoit Bay National Estuarine Research Reserve, East Falmouth, Massachusetts (USA). Tomograms from the experimental data indicate that fresh submarine groundwater discharge may shut down at high tide, whereas temperature data indicate that the discharge continues throughout the tidal cycle. Sensitivity analysis and synthetic modeling provide insight into resolving power in the presence of a time-varying saline water layer. In general, vertical electrodes and cross-hole measurements improve the inversion results regardless of the tidal level, whereas the resolution of surface arrays is more sensitive to time-varying saline water layer.
Inner pressure characterization of a sealed nickel-metal hydride cell
NASA Astrophysics Data System (ADS)
Cuscueta, D. J.; Salva, H. R.; Ghilarducci, A. A.
This paper studies the electrochemical behaviour of the pressure inside a sealed Ni-MH cell due to gases evolved under different charge/discharge currents and states of charge (SOC). The work is focused to determine the best procedure to get fast charge and long cycle life without detrimental effects on the battery and possible hazards affecting the safety of the user. The device was studied under a wide range of charge current (0.1-5 C), establishing that optimum conditions to minimize the inner pressure during uninterrupted use are obtained if either charge rates up to 0.5 C or higher rates not surpassing 90% of the nominal capacity are employed. Charge times corresponding to the range between 80% and 130% of the nominal capacity were also tested, analyzing the effect of overcharges on inner pressure, discharge capacity, efficiency and integrity of the cell. It was verified that charging the cell up to 130% at 2 C rate reaches an inner pressure 5 times higher than that obtained at 0.5 C. High rate discharge was also characterized at uninterrupted use of the cell, demonstrating the importance of the cut-off discharge criterion at high rates, to avoid the inner gases accumulation due to incomplete discharge of electrodes and overcharge in a following electrochemical cycle.
NASA Astrophysics Data System (ADS)
Beyer, Claus; Feldmann, Ingo; Gilmour, Dave; Hoffmann, Volker; Jakubowski, Norbert
2002-10-01
A Grimm-type glow discharge ion source has been developed and was coupled to a commercial inductively coupled plasma mass spectrometer (ICP-MS) with high mass resolution (Axiom, ThermoElemental, Winsford, UK) by exchanging the front plate of the ICP-MS interface system only. In addition to high discharge powers of up to 70 W, which are typical for a Grimm-type design, this source could be operated with relative high gas flow rates of up to 240 ml min -1. In combination with a high discharge voltage the signal intensities are reaching a constant level within the first 20 s after the discharge has started. An analytical characterization of this source is given utilizing a calibration using the steel standard reference material NIST 1261A-1265A. The sensitivity for the investigated elements measured with a resolution of 4000 is in the range of 500-6000 cps μg -1 g -1, and a relative standard deviation (R.S.D.) of the measured isotope relative to Fe of less than 8% for the major and minor components of the sample has been achieved. Limits of detection at ng g -1 levels could be obtained.
Comparative analysis of discharges into Lake Michigan, Phase I - Southern Lake Michigan.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veil, J. A.; Elcock, D.; Gasper, J. R.
2008-06-30
BP Products North America Inc. (BP) owns and operates a petroleum refinery located on approximately 1,700 acres in Whiting, East Chicago, and Hammond, Indiana, near the southern tip of Lake Michigan. BP provided funding to Purdue University-Calumet Water Institute (Purdue) and Argonne National Laboratory (Argonne) to conduct studies related to wastewater treatment and discharges. Purdue and Argonne are working jointly to identify and characterize technologies that BP could use to meet the previous discharge permit limits for total suspended solids (TSS) and ammonia after refinery modernization. In addition to the technology characterization work, Argonne conducted a separate project task, whichmore » is the subject of this report. In Phase I of a two-part study, Argonne estimated the current levels of discharge to southern Lake Michigan from significant point and nonpoint sources in Illinois, Indiana, and portions of Michigan. The study does not consider all of the chemicals that are discharged. Rather, it is narrowly focused on a selected group of pollutants, referred to as the 'target pollutants'. These include: TSS, ammonia, total and hexavalent chromium, mercury, vanadium, and selenium. In Phase II of the study, Argonne will expand the analysis to cover the entire Lake Michigan drainage basin.« less
NASA Astrophysics Data System (ADS)
Layes, Vincent; Monje, Sascha; Corbella, Carles; Schulz-von der Gathen, Volker; von Keudell, Achim; de los Arcos, Teresa
2017-05-01
In-vacuum characterization of magnetron targets after High Power Impulse Magnetron Sputtering (HiPIMS) has been performed by X-ray photoelectron spectroscopy (XPS). Al-Cr composite targets (circular, 50 mm diameter) mounted in two different geometries were investigated: an Al target with a small Cr disk embedded at the racetrack position and a Cr target with a small Al disk embedded at the racetrack position. The HiPIMS discharge and the target surface composition were characterized in parallel for low, intermediate, and high power conditions, thus covering both the Ar-dominated and the metal-dominated HiPIMS regimes. The HiPIMS plasma was investigated using optical emission spectroscopy and fast imaging using a CCD camera; the spatially resolved XPS surface characterization was performed after in-vacuum transfer of the magnetron target to the XPS chamber. This parallel evaluation showed that (i) target redeposition of sputtered species was markedly more effective for Cr atoms than for Al atoms; (ii) oxidation at the target racetrack was observed even though the discharge ran in pure Ar gas without O2 admixture, the oxidation depended on the discharge power and target composition; and (iii) a bright emission spot fixed on top of the inserted Cr disk appeared for high power conditions.
RECOVIR Software for Identifying Viruses
NASA Technical Reports Server (NTRS)
Chakravarty, Sugoto; Fox, George E.; Zhu, Dianhui
2013-01-01
Most single-stranded RNA (ssRNA) viruses mutate rapidly to generate a large number of strains with highly divergent capsid sequences. Determining the capsid residues or nucleotides that uniquely characterize these strains is critical in understanding the strain diversity of these viruses. RECOVIR (an acronym for "recognize viruses") software predicts the strains of some ssRNA viruses from their limited sequence data. Novel phylogenetic-tree-based databases of protein or nucleic acid residues that uniquely characterize these virus strains are created. Strains of input virus sequences (partial or complete) are predicted through residue-wise comparisons with the databases. RECOVIR uses unique characterizing residues to identify automatically strains of partial or complete capsid sequences of picorna and caliciviruses, two of the most highly diverse ssRNA virus families. Partition-wise comparisons of the database residues with the corresponding residues of more than 300 complete and partial sequences of these viruses resulted in correct strain identification for all of these sequences. This study shows the feasibility of creating databases of hitherto unknown residues uniquely characterizing the capsid sequences of two of the most highly divergent ssRNA virus families. These databases enable automated strain identification from partial or complete capsid sequences of these human and animal pathogens.
NASA Astrophysics Data System (ADS)
Sheppard, Marsha I.; Thibault, D. H.; Milton, G. M.; Reid, J. A. K.; Smith, P. A.; Stevens, K.
1995-03-01
Underground storage and disposal of hazardous wastes require an understanding of groundwater flow and the ability to locate recharge and discharge. Usually, recharge and discharge occur at a transition zone where dispersion/advection, molecular diffusion and biogeochemical processes control the fate of a contaminants leaving an underground facility. Appropriate landscape modelling for risk assessment cannot proceed until this interface is well defined and groundwater discharge can be mapped. Although discharge locations have traditionally been thought of as aquatic, the presence of animal licks suggests the possibility of terrestrial discharge. We have characterized a suspected terrestrial discharge, a well-used deer lick, (1) physically, through surficial mapping, and vegetation and soil profile analyses; (2) geophysically, through magnetic and very low-frequency electromagnetic tilt-angle surveys; (3) hydrogeologically, through water-table elevation measurements; (4) geochemically, through overburden analyses for 238U, 226Ra, 210Pb, Na, tritium, Cl and 36{Cl}/{Cl} atom ratios, as well as pore-water and groundwater analyses for pH, electrical conductivity (EC) and major anions and cations; and (5) thermally, through overburden-rock interface temperatures. Halophytic plants and sedges contained more Na, Cl and 238U than averages reported in the literature. Lineament alignment, coincident with elevated groundwater EC, supported the presence and position of a subsurface fracture. Groundwater chemistry suggested that interfering runoff from a nearby ridge masked the chemical signatures expected of deep groundwater but attest to the weak and possibly ephemeral nature of this discharge. Interpretation of the geochemical data was supported by solute transport modelling. Good agreement between the predictions using an unsaturated soil model, a simple wetland compartment model and the observed profile implied that evapotranspiration, seasonal water-table fluctuations and flooding, and sorption of 238U due to anoxia deep in the overburden are major processes shaping the overburden solute profile. This evidence strongly supported the hypothesis that the site is a location where deep groundwater (groundwater from depths of 500-1000 m) discharges.
NASA Astrophysics Data System (ADS)
Jang, C. S.; Liu, C. W.
2014-12-01
The Tatun volcanic area is the only potential volcanic geothermal region in the Taiwan island, and abundant in hot spring resources owing to stream water mixing with fumarolic gases. According to the Meinzer's classification, spring temperatures and discharge rates are the most important properties for characterizing spring classifications. This study attempted to spatially characterize spring temperatures and discharge rates in the Tatun volcanic area, Taiwanusing indicator kriging (IK). First, data on spring temperatures and discharge rates, which were collected from surveyed data of the Taipei City Government, were divided into high, moderate and low categories according to spring classification criteria, and the various categories were regarded as estimation thresholds. Then, IK was adopted to model occurrence probabilities of specified temperatures and discharge rates in springs, and to determine their classifications based on estimated probabilities. Finally, nine combinations were obtained from the classifications of temperatures and discharge rates in springs. Moreover, the combinations and features of spring water were spatially quantified according to seven sub-zones of spring utilization. A suitable and sustainable development strategy of the spring area was proposed in each sub-zone based on probability-based combinations and features of spring water.The research results reveal that the probability-based classifications using IK provide an excellent insight in exploring the uncertainty of spatial features in springs, and can provide Taiwanese government administrators with detailed information on sustainable spring utilization and conservation in the overexploited spring tourism areas. The sub-zones BT (Beitou), RXY (Rd. Xingyi), ZSL (Zhongshanlou) and LSK (Lengshuikeng) with high or moderate discharge rates are suitable to supply spring water for tourism hotels.Local natural hot springs should be planned in the sub-zones DBT (Dingbeitou), ZSL, XYK (Xiayoukeng), and MC (Macao) with low discharge rates, and low or moderate temperatures, particularly in riverbeds or valleys.Keywords: Spring; Temperature; Discharge rate; Indicator kriging; Uncertainty
Jadcherla, Sudarshan; Khot, Tanvi; Moore, Rebecca; Malkar, Manish; Gulati, Ish; Slaughter, Jonathan
2017-01-01
Objective To test the hypothesis that oral (PO) feeding at first neonatal intensive care unit (NICU) discharge is associated with less neurodevelopmental impairment and better feeding milestones, as compared with discharge with a gastrostomy tube (g-tube). Study design We studied outcomes for a retrospective cohort of 194 neonates < 37 weeks gestation referred for evaluation and management of feeding difficulties between July 2006–July 2012. Discharge milestones, length of hospitalization, and Bayley Scales of Infant Development scores at 18–24 months were examined. Chi-Square, Mann-Whitney U, or t-tests and multivariable logistic regression models were used. Results 60% (n=117) of infants were discharged on PO feedings; of these, 96% remained PO-fed at 1-year. The remaining 40% (n=77) were discharged on g-tube feedings; of these, 31 (40%) remained g-tube dependent, 17 (22%) became PO-fed, and 29 (38%) were on PO and g-tube feedings at one year. Infants discharged on a g-tube had lower cognitive (p<0.01), communication (p=0.03), and motor (p<0.01) composite scores. The presence of a g-tube, younger gestation, bronchopulmonary dysplasia, or intraventricular hemorrhage was significantly associated with neurodevelopmental delay. Conclusions For infants referred for feeding concerns, g-tube evaluations and feeding management, the majority did not require a g-tube. Full PO feeding at first NICU discharge was associated with superior feeding milestones and less long-term neurodevelopmental impairment, relative to full or partial g-tube feeding. Evaluation and feeding management before and after g-tube placement may improve long-term feeding and neurodevelopmental outcomes. PMID:27939123
A four kHz repetition rate compact TEA CO2 laser
NASA Astrophysics Data System (ADS)
Zheng, Yijun; Tan, Rongqing
2013-09-01
A compact transversely excited atmospheric (TEA) CO2 laser with high repetition-rate was reported. The size of the laser is 380 mm×300 mm×200 mm, and the discharge volume is 12×103 mm3. The laser cavity has a length of 320mm and consists of a totally reflective concave mirror with a radius of curvature of 4 m (Cu metal substrate coated with Au) and a partially reflecting mirror. The ultraviolet preionization makes the discharge even and stable,the output energy can be as high as 28 mJ under the circumstance of free oscillation, and the width of the light pulse is 60ns.To acquire the high wind velocity, a turbocharger is used in the system of the fast-gas flow cycle. When the wind speed is 100m/s, the repetition rate of the transversely excited atmospheric CO2 laser is up to 2 kHz. On this basis, a dual modular structure with two sets of the gas discharge unit is adopted to obtain a higher pulse repetition frequency output. The dual discharge unit composed two sets of electrodes and two sets of turbo fan. Alternate trigger technology is used to make the two sets of discharge module work in turn with repetition frequency of 2 kHz, the discharge interval of two sets of the gas discharge unit can be adjusted continuously from 20 microseconds to 250 microseconds. Under the conditions of maintaining the other parameters constant, the repetition frequency of the laser pulse is up to 4 kHz. The total size of laser with dual modular structure is 380mm×520mm×200mm, and the discharge volume is 24×103 mm3 with the cavity length of 520mm.
Soil thaw effects on river discharge recessions of a subarctic catchment
NASA Astrophysics Data System (ADS)
Ploum, Stefan; Lyon, Steve; Teuling, Ryan; van der Velde, Ype
2017-04-01
Thawing permafrost in circumpolar regions is likely to change subsurface hydrology. In high latitude areas continuous permafrost is expected to partially thaw leading to sporadic permafrost with deeper groundwater flow paths. Moreover, freeze-thaw cycles of the shallow subsurface are likely to increase. River discharge recession analysis can be particularly useful to understand the hydrological effects of a thawing Arctic. Here we examine river discharge recessions of the Abiskojokka, a 560 km2 watershed with sporadic permafrost, using a river discharge record of 30 years (1985 - 2015). Snow observation records were used to separate river recessions in snowmelt and snowfree periods. We found significant differences between recessions during the snowmelt and snowfree seasons. During the snowmelt, recessions were close to linear (b=1.11), while during the snowfree period, recessions were more non-linear (b=1.54). Typically, non-linearity has been found to increase with discharge magnitude, while we observed the opposite (snowfree periods tend to have lower discharges than the snowmelt periods). We explain these contrasting results by hypothesizing that increased connectivity (increasing magnitude and number of water flow paths) between groundwater and stream leads to higher non-linearity. In temperate catchments without frozen soils, connectivity tends to increase with increasing discharge. In contrast, in Arctic systems, where soils are frozen, connectivity between groundwater and stream is limited. Therefore, thawing of frozen soils is expected to increase connectivity and thus non-linearity of river discharges. We tested this hypothesis with a detailed analysis of all spring flood recessions. Years with cold soil temperatures (b=1.08) and years with a below median snowpack depth were found to have progressively linear slopes (b=1.08 and 1.01 respectively). On the other hand, years with warm soil conditions show increasingly non-linear recessions (b=1.67). Although limited in spatial extent, these results further support our connectivity hypothesis, which predicts increasing non-linearity of river discharges (higher discharge peaks and lower low flows under the same precipitation regime) as permafrost thaws.
Liu, Mingkai; Miao, Yue-E; Zhang, Chao; Tjiu, Weng Weei; Yang, Zhibin; Peng, Huisheng; Liu, Tianxi
2013-08-21
A three dimensional (3D) polyaniline (PANI)-graphene nanoribbon (GNR)-carbon nanotube (CNT) composite, PANI-GNR-CNT, has been prepared via in situ polymerization of an aniline monomer on the surface of a GNR-CNT hybrid. Here, the 3D GNR-CNT hybrid has been conveniently prepared by partially unzipping the pristine multi-walled CNTs, while the residual CNTs act as "bridges" connecting different GNRs. The morphology and structure of the resulting hybrid materials have been characterized using transmission electron microscopy (TEM), scanning electron microscopy (SEM), Raman spectroscopy and X-ray diffraction (XRD). Electrochemical tests reveal that the hierarchical PANI-GNR-CNT composite based on the two-electrode cell possesses much higher specific capacitance (890 F g(-1)) than the GNR-CNT hybrid (195 F g(-1)) and neat PANI (283 F g(-1)) at a discharge current density of 0.5 A g(-1). At the same time, the PANI-GNR-CNT composite displays good cycling stability with a retention ratio of 89% after 1000 cycles, suggesting that this novel PANI-GNR-CNT composite is a promising candidate for energy storage applications.
NASA Astrophysics Data System (ADS)
Liu, Mingkai; Miao, Yue-E.; Zhang, Chao; Tjiu, Weng Weei; Yang, Zhibin; Peng, Huisheng; Liu, Tianxi
2013-07-01
A three dimensional (3D) polyaniline (PANI)-graphene nanoribbon (GNR)-carbon nanotube (CNT) composite, PANI-GNR-CNT, has been prepared via in situ polymerization of an aniline monomer on the surface of a GNR-CNT hybrid. Here, the 3D GNR-CNT hybrid has been conveniently prepared by partially unzipping the pristine multi-walled CNTs, while the residual CNTs act as ``bridges'' connecting different GNRs. The morphology and structure of the resulting hybrid materials have been characterized using transmission electron microscopy (TEM), scanning electron microscopy (SEM), Raman spectroscopy and X-ray diffraction (XRD). Electrochemical tests reveal that the hierarchical PANI-GNR-CNT composite based on the two-electrode cell possesses much higher specific capacitance (890 F g-1) than the GNR-CNT hybrid (195 F g-1) and neat PANI (283 F g-1) at a discharge current density of 0.5 A g-1. At the same time, the PANI-GNR-CNT composite displays good cycling stability with a retention ratio of 89% after 1000 cycles, suggesting that this novel PANI-GNR-CNT composite is a promising candidate for energy storage applications.
Strong damping of the localized surface plasmon resonance of Ag nanoparticles by Ag2O.
Wu, Qingmen; Si, Mengting; Zhang, Bing; Zhang, Kang; Li, Huanhuan; Mi, Longfei; Jiang, Yang; Rong, Yan; Chen, Junling; Fang, Yingcui
2018-07-20
By studying oxidation of AgNPs (Ag nanoparticles) and decomposition of the produced silver oxide, we demonstrate that the localized surface plasmon resonance (LSPR) of AgNPs was damped by Ag 2 O produced during oxygen plasma irradiation (OPI). The AgNPs were fabricated by evaporation of high pure silver under high vacuum. The oxidation was conducted in oxygen plasma generated by radio frequency glow discharging in vacuum, and the decomposition was performed by annealing the silver oxide in nitrogen ambient at temperatures ranging from room temperature to 450 °C. Samples were characterized by color, absorption spectra, surface enhanced Raman scattering, x-ray photoelectron spectroscopy, and field emission scanning electron microscopy. The bandgap of the silver oxide was calculated. We propose that AgNPs are only partially oxidized into silver oxide during OPI, and the LSPR of the AgNPs left without being oxidation is strongly damped by the produced silver oxide. This LSPR damping is responsible for the transparency of the sample after OPI for 2 s.
Numerical studies of the effects of jet-induced mixing on liquid-vapor interface condensation
NASA Technical Reports Server (NTRS)
Lin, Chin-Shun
1989-01-01
Numerical solutions of jet-induced mixing in a partially full cryogenic tank are presented. An axisymmetric laminar jet is discharged from the central part of the tank bottom toward the liquid-vapor interface. Liquid is withdrawn at the same volume flow rate from the outer part of the tank. The jet is at a temperature lower than the interface, which is maintained at a certain saturation temperature. The interface is assumed to be flat and shear-free and the condensation-induced velocity is assumed to be negligibly small compared with radial interface velocity. Finite-difference method is used to solve the nondimensional form of steady state continuity, momentum, and energy equations. Calculations are conducted for jet Reynolds numbers ranging from 150 to 600 and Prandtl numbers ranging from 0.85 to 2.65. The effects of above stated parameters on the condensation Nusselt and Stanton numbers which characterize the steady-state interface condensation process are investigated. Detailed analysis to gain a better understanding of the fundamentals of fluid mixing and interface condensation is performed.
Polymer composites with graphene nanofillers: electrical properties and applications.
Tjong, Sie Chin
2014-02-01
Graphene with extraordinary high elastic modulus and excellent electrical conductivity has good prospects for use as the filler material for fabricating novel polymer composites designed for electrostatic discharge and EMI shielding protection, field emission, gas sensor, and fuel cell applications. Large amounts of graphene oxide (GO) can be obtained by wet chemical oxidation of graphite into a mixture of concentrated sulfuric acid, sodium nitrate and potassium permanganate. Accordingly, carbon atoms in the basal plane and edges of GO are decorated with oxygenated functional groups, forming an electrical insulator. To restore electrical conductivity, chemical reduction or thermal annealing is needed to eliminate oxygenated groups of GO. However, such treatments induce internal defects and remove oxygenated atoms of GO partially. The remnant-oxygenated groups affect electrical conductivity of graphene greatly. Nevertheless, reduced graphene oxide and thermally reduced graphene oxide are sufficiently conductive to form polymer nanocomposites at very low percolation threshold. This review provides the fundamentals and state-of-the-art developments in the fabrication methods and electrical property characterizations as well as the applications of novel graphene/polymer nanocomposites. Particular attention is paid to their processing-structural-electrical property relationships.
Strong damping of the localized surface plasmon resonance of Ag nanoparticles by Ag2O
NASA Astrophysics Data System (ADS)
Wu, Qingmen; Si, Mengting; Zhang, Bing; Zhang, Kang; Li, Huanhuan; Mi, Longfei; Jiang, Yang; Rong, Yan; Chen, Junling; Fang, Yingcui
2018-07-01
By studying oxidation of AgNPs (Ag nanoparticles) and decomposition of the produced silver oxide, we demonstrate that the localized surface plasmon resonance (LSPR) of AgNPs was damped by Ag2O produced during oxygen plasma irradiation (OPI). The AgNPs were fabricated by evaporation of high pure silver under high vacuum. The oxidation was conducted in oxygen plasma generated by radio frequency glow discharging in vacuum, and the decomposition was performed by annealing the silver oxide in nitrogen ambient at temperatures ranging from room temperature to 450 °C. Samples were characterized by color, absorption spectra, surface enhanced Raman scattering, x-ray photoelectron spectroscopy, and field emission scanning electron microscopy. The bandgap of the silver oxide was calculated. We propose that AgNPs are only partially oxidized into silver oxide during OPI, and the LSPR of the AgNPs left without being oxidation is strongly damped by the produced silver oxide. This LSPR damping is responsible for the transparency of the sample after OPI for 2 s.
Information analysis of posterior canal afferents in the turtle, Trachemys scripta elegans.
Rowe, Michael H; Neiman, Alexander B
2012-01-24
We have used sinusoidal and band-limited Gaussian noise stimuli along with information measures to characterize the linear and non-linear responses of morpho-physiologically identified posterior canal (PC) afferents and to examine the relationship between mutual information rate and other physiological parameters. Our major findings are: 1) spike generation in most PC afferents is effectively a stochastic renewal process, and spontaneous discharges are fully characterized by their first order statistics; 2) a regular discharge, as measured by normalized coefficient of variation (cv*), reduces intrinsic noise in afferent discharges at frequencies below the mean firing rate; 3) coherence and mutual information rates, calculated from responses to band-limited Gaussian noise, are jointly determined by gain and intrinsic noise (discharge regularity), the two major determinants of signal to noise ratio in the afferent response; 4) measures of optimal non-linear encoding were only moderately greater than optimal linear encoding, indicating that linear stimulus encoding is limited primarily by internal noise rather than by non-linearities; and 5) a leaky integrate and fire model reproduces these results and supports the suggestion that the combination of high discharge regularity and high discharge rates serves to extend the linear encoding range of afferents to higher frequencies. These results provide a framework for future assessments of afferent encoding of signals generated during natural head movements and for comparison with coding strategies used by other sensory systems. This article is part of a Special Issue entitled: Neural Coding. Copyright © 2011 Elsevier B.V. All rights reserved.
Sustained diffusive alternating current gliding arc discharge in atmospheric pressure air
NASA Astrophysics Data System (ADS)
Zhu, Jiajian; Gao, Jinlong; Li, Zhongshan; Ehn, Andreas; Aldén, Marcus; Larsson, Anders; Kusano, Yukihiro
2014-12-01
Rapid transition from glow discharge to thermal arc has been a common problem in generating stable high-power non-thermal plasmas especially at ambient conditions. A sustained diffusive gliding arc discharge was generated in a large volume in atmospheric pressure air, driven by an alternating current (AC) power source. The plasma column extended beyond the water-cooled stainless steel electrodes and was stabilized by matching the flow speed of the turbulent air jet with the rated output power. Comprehensive investigations were performed using high-speed movies measured over the plasma column, synchronized with simultaneously recorded current and voltage waveforms. Dynamic details of the novel non-equilibrium discharge are revealed, which is characterized by a sinusoidal current waveform with amplitude stabilized at around 200 mA intermediate between thermal arc and glow discharge, shedding light to the governing mechanism of the sustained spark-suppressed AC gliding arc discharge.
NASA Astrophysics Data System (ADS)
Zeng, Fan Wen; Wang, Hong; Lin, Hua-Tay
2013-07-01
Lead zirconate titanate (PZT) multilayer actuators with an interdigital electrode design were studied under high electric fields (3 and 6 kV/mm) in a unipolar cycling mode. A 100 Hz sine wave was used in cycling. Five specimens tested under 6 kV/mm failed from 3.8 × 105 to 7 × 105 cycles, whereas three other specimens tested under 3 kV/mm were found to be still functional after 108 cycles. Variations in piezoelectric and dielectric responses of the tested specimens were observed during the fatigue test, depending on the measuring and cycling conditions. Selected fatigued and damaged actuators were characterized using an impedance analyzer or small signal measurement. Furthermore, involved fatigue and failure mechanisms were investigated using scanning acoustic microscope and scanning electron microscope. The extensive cracks and porous regions were revealed across the PZT layers on the cross sections of a failed actuator. The results from this study have demonstrated that the high-field cycling can accelerate the fatigue of PZT stacks as long as the partial discharge is controlled. The small signal measurement can also be integrated into the large signal measurement to characterize the fatigue response of PZT stacks in a more comprehensive basis. The former can further serve as an experimental method to test and monitor the behavior of PZT stacks.
Short hospitalization after caesarean delivery: effects on maternal pain and stress at discharge.
Zanardo, Vincenzo; Giliberti, Lara; Volpe, Francesca; Simbi, Alphonse; Guerrini, Pietro; Parotto, Matteo; Straface, Gianluca
2018-09-01
To characterize predischarge maternal pain and stress after caesarean delivery and short hospitalization. This is a descriptive study with 60 women in the postoperative period of caesarean section and 60 control women after vaginal delivery. Pain and stress were measured by McGill Pain Questionnaire (MGPQ) and by the Stress Measure (Psychological Stress Measure (PSM)), respectively, at mother-infant dyad discharge, scheduled at 36 hours after delivery. Caesarean section was the delivery modality with the highest MGPQ pain and sensorial, evaluative and mixed pain descriptive categories scores. The pain location involved lower abdomen, with associated localizations at back, breast and shoulders. Conversely, vaginal delivery was the delivery modality with the highest stress scores. This study provides important information on the quality of care implications of early discharge practices in puerperae after caesarean delivery, a critical time characterized by qualitatively and quantitatively high pain and stress.
Daniele Tonina; John M. Buffington
2011-01-01
Hyporheic flow results from the interaction between streamflow and channel morphology and is an important component of stream ecosystems because it enhances water and solute exchange between the river and its bed. Hyporheic flow in pool-riffle channels is particularly complex because of three-dimensional topography that spans a range of partially to fully submerged...
Liu, Jingcun; Zhang, Guogang; Dong, Jinlong; Wang, Jianhua
2015-11-20
Detecting partial discharge (PD) is an effective way to evaluate the condition of high-voltage electrical equipment insulation. The UHF detection method has attracted attention due to its high sensitivity, strong interference resistance, and ability to locate PDs. In this paper, a miniaturized equiangular spiral antenna (ESA) for UHF detection that uses a printed circuit board is proposed. I-shaped, L-shaped, and C-shaped microstrip baluns were designed to match the impedance between the ESA and coaxial cable and were verified by a vector network analyzer. For comparison, three other types of UHF antenna were also designed: A microstrip patch antenna, a microstrip slot antenna, and a printed dipole antenna. Their antenna factors were calibrated in a uniform electric field of different frequencies modulated in a gigahertz transverse electromagnetic cell. We performed comparison experiments on PD signal detection using an artificial defect model based on the international IEC 60270 standard. We also conducted time-delay test experiments on the ESA sensor to locate a PD source. It was found that the proposed ESA sensor meets PD signal detection requirements. The sensor's compact size makes it suitable for internal installation in high-voltage electrical equipment.
Liu, Jingcun; Zhang, Guogang; Dong, Jinlong; Wang, Jianhua
2015-01-01
Detecting partial discharge (PD) is an effective way to evaluate the condition of high-voltage electrical equipment insulation. The UHF detection method has attracted attention due to its high sensitivity, strong interference resistance, and ability to locate PDs. In this paper, a miniaturized equiangular spiral antenna (ESA) for UHF detection that uses a printed circuit board is proposed. I-shaped, L-shaped, and C-shaped microstrip baluns were designed to match the impedance between the ESA and coaxial cable and were verified by a vector network analyzer. For comparison, three other types of UHF antenna were also designed: A microstrip patch antenna, a microstrip slot antenna, and a printed dipole antenna. Their antenna factors were calibrated in a uniform electric field of different frequencies modulated in a gigahertz transverse electromagnetic cell. We performed comparison experiments on PD signal detection using an artificial defect model based on the international IEC 60270 standard. We also conducted time-delay test experiments on the ESA sensor to locate a PD source. It was found that the proposed ESA sensor meets PD signal detection requirements. The sensor’s compact size makes it suitable for internal installation in high-voltage electrical equipment. PMID:26610506
NASA Technical Reports Server (NTRS)
Bever, R. S.
1977-01-01
Several dummy tubes imitating the IUE Camera System design were encapsulated with Solithane 2, Conathane EN-11, Green and Black Hysols and SMRD 432. Various flaws were purposefully placed in some of these. Partial discharge testing in vacuum under direct voltage conditions was carried once a week for 12 weeks, 15 kv dc being applied during normal working hours for 40 hours duration per week. None of the units showed much damage during this time judging by the P.D. energy histograms. A more complete mathematical presentation is given on diffusion and permeation than previously. Measurements of diffusion constants for various silicone rubbers are carried out by the Time-Lag method and compared to other determinations in the literature. Calculations of the time required for diffusion through a thick wall are demonstrated in the long time approximation and for dimensions pertaining to void and wall sizes of a delamination problem in the LANDSAT-C vidicon tubes. An actual delaminated LANDSAT-C tube and some facsimiles are immersed in vacuum for long periods and tested for catastrophic breakdown due to diffusion of gas, by application of high voltage.
Water Resources Data, Alabama, Water Year 2002
Pearman, J.L.; Stricklin, V.E.; Psinakis, W.L.
2003-01-01
Water resources data for the 2002 water year for Alabama consist of records of stage, discharge, and water quality of streams; stages and contents of lakes and reservoirs; and water levels in wells. This report includes records on both surface and ground water in the State. Specifically, it contains: (1) discharge records for 131 streamflow-gaging stations, for 41 partial-record or miscellaneous streamflow stations; (2) stage and content records for 14 lakes and reservoirs and stage at 47 stations; (3) water-quality records for 12 streamflow-gaging stations, for 17 ungaged streamsites, and for 2 precipitation stations; (4) water temperature at 14 surfacewater stations; (5) specific conductance and dissolved oxygen at 12 stations; (6) turbidity at 3 stations; (7) sediment data at 6 stations; (8) water-level records for 2 recording observation wells; and (9) water-quality records for 21 ground-water stations. Also included are lists of active and discontinued continuous-record surface-water-quality stations, and partial-record and miscellaneous surface-water-quality stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating Federal, State, and local agencies in Alabama.
Water Resources Data, Alabama, Water Year 2003
Psinakis, W.L.; Lambeth, D.S.; Stricklin, V.E.; Treece, M.W.
2004-01-01
Water resources data for the 2003 water year for Alabama consist of records of stage, discharge, and water quality of streams; stages and contents of lakes and reservoirs; and water levels in wells. This report includes records on both surface and ground water in the State. Specifically, it contains: (1) discharge records for 130 streamflow-gaging stations, for 29 partial-record or miscellaneous streamflow stations; (2) stage and content records for 14 lakes and reservoirs and stage at 46 stations; (3) water-quality records for 12 streamflow-gaging stations, for 29 ungaged streamsites, and for 1 precipitation stations; (4) water temperature at 12 surfacewater stations; (5) specific conductance and dissolved oxygen at 12 stations; (6) turbidity at 3 stations; (7) sediment data at 6 stations; (8) water-level records for 2 recording observation wells; and (9) water-quality records for 9 ground-water stations. Also included are lists of active and discontinued continuous-record surface-water-quality stations, and partial-record and miscellaneous surface-water-quality stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating Federal, State, and local agencies in Alabama.
Water Resources Data, Alabama, Water Year 2004
Psinakis, W.L.; Lambeth, D.S.; Stricklin, V.E.; Treece, M.W.
2005-01-01
Water resources data for the 2004 water year for Alabama consist of records of stage, discharge, and water quality of streams; stages and contents of lakes and reservoirs; and water levels in wells. This report includes records on both surface and ground water in the State. Specifically, it contains: (1) discharge records for 131 streamflow-gaging stations, for 19 partial-record or miscellaneous streamflow stations; (2) stage and content records for 16 lakes and reservoirs and stage at 44 stations; (3) water-quality records for 21 streamflow-gaging stations, for 11 ungaged streamsites, and for 1 precipitation stations; (4) water temperature at 20 surface-water stations; (5) specific conductance and dissolved oxygen at 20 stations; (6) turbidity at 5 stations; (7) sediment data at 6 stations; (8) water-level records for 2 recording observa-tion wells; and (9) water-quality records for 6 ground-water stations. Also included are lists of active and discontinued continuous-record surface-water-quality stations, and partial-record and miscellaneous sur-face-water-quality stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating Federal, State, and local agencies in Alabama.
Water Resources Data, Alabama, Water Year 2005
Psinakis, W.L.; Lambeth, D.S.; Stricklin, V.E.; Treece, M.W.
2006-01-01
Water resources data for the 2005 water year for Alabama consist of records of stage, discharge, and water quality of streams; stages and contents of lakes and reservoirs; and water levels in wells. This report includes records on both surface and ground water in the State. Specifically, it contains: (1) discharge records for 131 streamflow-gaging stations and 23 partial-record or miscellaneous streamflow stations; (2) stage and content records for 14 lakes and reservoirs and stage at 44 stations; (3) water-quality records for 125 streamflow-gaging stations and 67 ungaged streamsites; (4) water temperature at 179 surface-water stations; (5) specific conductance at 180 stations; (6) dissolved oxygen at 17 stations; (7) turbidity at 52 stations; (8) sediment data at 2 stations; (9) water-level records for 2 recording observation wells; and (10) water-quality records for 6 ground-water stations. Also included are lists of active and discontinued continuous-record surface-water-quality stations, and partial-record and miscellaneous surface- water-quality stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating Federal, State, and local agencies in Alabama.
Zhang, Xiaoxing; Li, Xin; Luo, Chenchen; Dong, Xingchen; Zhou, Lei
2015-01-01
Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors’ resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors. PMID:26569245
Zhang, Xiaoxing; Li, Xin; Luo, Chenchen; Dong, Xingchen; Zhou, Lei
2015-11-11
Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors' resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors.
NASA Astrophysics Data System (ADS)
Peters, F.; Hünnekens, B.; Wieneke, S.; Militz, H.; Ohms, G.; Viöl, W.
2017-11-01
In this study, three different dielectric barrier discharges, based on the same setup and run with the same power supply, are characterized by emission spectroscopy with regards to the reduced electrical field strength, and the rotational, vibrational and electron temperature. To compare discharges common for the treatment on wood, a coplanar surface barrier discharge, a direct dielectric barrier discharge and a jet system/remote plasma are chosen. To minimize influences due to the setups or power, the discharges are realized with the same electrodes and power supply and normalized to the same power. To evaluate the efficiency of the different discharges and the influence on treated materials, the surface free energy is determined on a maple wood, high density fiberboard and wood plastic composite. The influence is measured depending on the treatment time, with the highest impact in the time of 5 s.
Vertical Mixing in the Dead Sea
NASA Astrophysics Data System (ADS)
Gertman, Isaac; Ozer, Tal; Katsenelson, Boris; Lensky, Nadav
2015-04-01
For hundreds of years, the Dead Sea was characterized by a stable haline stratification, supported by runoff. The penetration of the winter convection was limited to an upper mixed layer (UML) of about 30-50 m. Below the UML, a stable halocline prevented the mixing. As a result of the runoff reduction, the UML salinity increased and the gravitational stability diminished. During the winter of 1978-1979, the sea water overturned, ending the long-term stable hydrological regime. Since 1979, the haline stratification structure reoccurred twice after extremely rainy winters, in 1980-82 and 1992-1995. In other years, the sea was entirely mixed by winter thermal convection ( which occurs from November to March ) and had a seasonal pycnocline beneath the UML during summer. Profiles of temperature and quasi-salinity (density anomaly from 1000 kg/m3 for the chosen reference temperature of 32° C) during the last 19 years, show the formation of summer ``overturning halocline'' beneath the UML, and the thermocline that supports the stable stratification. Another warm and saline layer is formed also during the summer period near the bottom. This layer spreads from the southern part of the sea, where end-brine is discharged to the sea from the Israeli and Jordanian salt plants' evaporation ponds. The end-brine has extremely high salinity (˜ 350 g/kg) and, in spite of the high temperatures ( ˜ 45° C), high density (1350 kg/m^3), it therefore spreads as a gravitational current in the Dead Sea deep basin. Estimation of the density ratio (Rρ) for the Dead Sea water (where measurements of water salinity is quite difficult) was done using quasi-salinity (σ32) and potential temperature (θ): Rρ= [α(partialθ/partial z)]/[β(partial σ32/partial z)], where α and β are temperature expansion and quasi-salinity contraction coefficients respectively. The values of α and β for the Dead Sea water were defined from water samples collected during 2008. The Rρ values confirm that the summer Dead Sea thermohaline structure is appropriate for double diffusion mixing. A salt fingers regime beneath the UML (1.3< Rρ
Effects of oxygen partial pressure on Li-air battery performance
NASA Astrophysics Data System (ADS)
Kwon, Hyuk Jae; Lee, Heung Chan; Ko, Jeongsik; Jung, In Sun; Lee, Hyun Chul; Lee, Hyunpyo; Kim, Mokwon; Lee, Dong Joon; Kim, Hyunjin; Kim, Tae Young; Im, Dongmin
2017-10-01
For application in electric vehicles (EVs), the Li-air battery system needs an air intake system to supply dry oxygen at controlled concentration and feeding rate as the cathode active material. To facilitate the design of such air intake systems, we have investigated the effects of oxygen partial pressure (≤1 atm) on the performance of the Li-air cell, which has not been systematically examined. The amounts of consumed O2 and evolved CO2 from the Li-air cell are measured with a custom in situ differential electrochemical gas chromatography-mass spectrometry (DEGC-MS). The amounts of consumed O2 suggest that the oxygen partial pressure does not affect the reaction mechanism during discharge, and the two-electron reaction occurs under all test conditions. On the other hand, the charging behavior varies by the oxygen partial pressure. The highest O2 evolution ratio is attained under 70% O2, along with the lowest CO2 evolution. The cell cycle life also peaks at 70% O2 condition. Overall, an oxygen partial pressure of about 0.5-0.7 atm maximizes the Li-air cell capacity and stability at 1 atm condition. The findings here indicate that the appropriate oxygen partial pressure can be a key factor when developing practical Li-air battery systems.
A SIMPLE HYDROLOGICAL MODEL FOR WATERSHED CHARACTERIZATION
Catchment behavior is characterized with a variety of metrics - discharge, chemical export, biological activity, to name a few. Catchments have complex temporal behavior, e.g., summer and winter storm recessions and nutrient export may look nothing alike. Further, catchment res...
Workload Characterization of CFD Applications Using Partial Differential Equation Solvers
NASA Technical Reports Server (NTRS)
Waheed, Abdul; Yan, Jerry; Saini, Subhash (Technical Monitor)
1998-01-01
Workload characterization is used for modeling and evaluating of computing systems at different levels of detail. We present workload characterization for a class of Computational Fluid Dynamics (CFD) applications that solve Partial Differential Equations (PDEs). This workload characterization focuses on three high performance computing platforms: SGI Origin2000, EBM SP-2, a cluster of Intel Pentium Pro bases PCs. We execute extensive measurement-based experiments on these platforms to gather statistics of system resource usage, which results in workload characterization. Our workload characterization approach yields a coarse-grain resource utilization behavior that is being applied for performance modeling and evaluation of distributed high performance metacomputing systems. In addition, this study enhances our understanding of interactions between PDE solver workloads and high performance computing platforms and is useful for tuning these applications.
de Mestral, Charles; Salata, Konrad; Hussain, Mohamad A; Kayssi, Ahmed; Al-Omran, Mohammed; Roche-Nagle, Graham
2018-04-18
Early readmission to hospital after surgery is an omnipresent quality metric across surgical fields. We sought to understand the relative importance of hospital readmission among all health services received after hospital discharge. The aim of this study was to characterize 30-day postdischarge cost and risk of an emergency department (ED) visit, readmission, or death after hospitalization for elective major vascular surgery. This is a population-based retrospective cohort study of patients who underwent elective major vascular surgery - carotid endarterectomy, EVAR, open AAA repair, bypass for lower extremity peripheral arterial disease - in Ontario, Canada, between 2004 and 2015. The outcomes of interest included quality metrics - ED visit, readmission, death - and cost to the Ministry of Health, within 30 days of discharge. Costs after discharge included those attributable to hospital readmission, ED visits, rehab, physician billing, outpatient nursing and allied health care, medications, interventions, and tests. Multivariable regression models characterized the association of pre-discharge characteristics with the above-mentioned postdischarge quality metrics and cost. A total of 30,752 patients were identified. Within 30 days of discharge, 2588 (8.4%) patients were readmitted to hospital and 13 patients died (0.04%). Another 4145 (13.5%) patients visited an ED without requiring admission. Across all patients, over half of 30-day postdischarge costs were attributable to outpatient care. Patients at an increased risk of an ED visit, readmission, or death within 30 days of discharge differed from those patients with relatively higher 30-day costs. Events occurring outside the hospital setting should be integral to the evaluation of quality of care and cost after hospitalization for major vascular surgery.
2004-11-01
Hall thruster characteristics there was prepared Hall thruster model of the SPT-100 type for these experiments and there were manufactured the required discharge chamber parts (rings) made of the Russian BN-SiO2 (borosil) ceramics and of the Russian AIN-BN (ABN) and Western ABN ceramics having secondary electron emission yield (SEEY) different from that one for borosil. These parts were replaceable during experiments. Thruster model was equipped by set of the near wall probes mounted at external discharge chamber wall. There was made characterization
NASA Technical Reports Server (NTRS)
Leung, P. L.
1984-01-01
This paper discusses the measurements of the electromagnetic interference (EMI) generated during discharges of Mylar samples. The two components of EMI, the conducted emission and the radiated emission, are characterized by the replacement current and the radiated RF spectrum respectively. The measured radiated RF spectra reveal important information on the source of the electromagnetic radiation. The possible sources are the replacement current pulse and the discharged generated plasma. The scaling of the amplitudes of the EMI, as a function of the area of the test sample, is also discussed.
Annual Gaseous Electronics Conference (41st) Held in Minneapolis, Minnesota on 18-21 October 1988
1989-09-01
IMPEDANCE J. W. Butterbaugh, L. D. Baston and H. H. Sawin E-34. TEMPORAL AND SPATIAL PLASMA POTENTIAL MEASUREMENT IN PARALLEL PLATE RF GLOW DISCHARGE C...DISCHARGES P. J. Hargis, Jr. and K. E. Grecr.’ 10:51 - 11:04 LA-4. CHARACTERIZATION OF CF4 PLASMA KINETICS BY MODULATED POWER RELAXATION L. D. Baston and H. H...No. ECS-8704529 5n, E-33 Measurement and Analysis of RF Glow Discharge Electrical Impedance, J.W. BUTTERBAUGH, L.D. BASTON , and H.H. SAWIN
Understanding the occupational and organizational boundaries to safe hospital discharge.
Waring, Justin; Marshall, Fiona; Bishop, Simon
2015-01-01
Safe hospital discharge relies upon communication and coordination across multiple occupational and organizational boundaries. Our aim was to understand how these boundaries can exacerbate health system complexity and represent latent sociocultural threats to safe discharge. An ethnographic study was conducted in two local health and social care systems (health economies) in England, focusing on two clinical areas: stroke and hip fracture patients. Data collection involved 345 hours of observations and 220 semi-structured interviews with health and social care professionals, patients and their lay carers. Hospital discharge involves a dynamic network of interactions between heterogeneous health and social care actors, each characterized by divergent ways of organizing discharge activities; cultures of collaboration and interaction and understanding of what discharge involves and how it contributes to patient recovery. These interrelated dimensions elaborate the occupational and organisational boundaries that can influence communication and coordination in hospital discharge. Hospital discharge relies upon the coordination of multiple actors working across occupational and organizational boundaries. Attention to the sociocultural boundaries that influence communication and coordination can help inform interventions that might support enhanced discharge safety. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Analytical model of a corona discharge from a conical electrode under saturation
NASA Astrophysics Data System (ADS)
Boltachev, G. Sh.; Zubarev, N. M.
2012-11-01
Exact partial solutions are found for the electric field distribution in the outer region of a stationary unipolar corona discharge from an ideal conical needle in the space-charge-limited current mode with allowance for the electric field dependence of the ion mobility. It is assumed that only the very tip of the cone is responsible for the discharge, i.e., that the ionization zone is a point. The solutions are obtained by joining the spherically symmetric potential distribution in the drift space and the self-similar potential distribution in the space-charge-free region. Such solutions are outside the framework of the conventional Deutsch approximation, according to which the space charge insignificantly influences the shape of equipotential surfaces and electric lines of force. The dependence is derived of the corona discharge saturation current on the apex angle of the conical electrode and applied potential difference. A simple analytical model is suggested that describes drift in the point-plane electrode geometry under saturation as a superposition of two exact solutions for the field potential. In terms of this model, the angular distribution of the current density over the massive plane electrode is derived, which agrees well with Warburg's empirical law.
Master equation and runaway speed of the Francis turbine
NASA Astrophysics Data System (ADS)
Zhang, Zh.
2018-04-01
The master equation of the Francis turbine is derived based on the combination of the angular momentum (Euler) and the energy laws. It relates the geometrical design of the impeller and the regulation settings (guide vane angle and rotational speed) to the discharge and the power output. The master equation, thus, enables the complete characteristics of a given Francis turbine to be easily computed. While applying the energy law, both the shock loss at the impeller inlet and the swirling loss at the impeller exit are taken into account. These are main losses which occur at both the partial load and the overloads and, thus, dominantly influence the characteristics of the Francis turbine. They also totally govern the discharge of the water through the impeller when the impeller is found in the standstill. The computations have been performed for the discharge, the hydraulic torque and the hydraulic efficiency. They were also compared with the available measurements on a model turbine. Excellent agreement has been achieved. The computations also enable the runaway speed of the Francis turbine and the related discharge to be determined as a function of the setting angle of the guide vanes.
Modelling hydrological conditions in the maritime forest region of south-western Nova Scotia
NASA Astrophysics Data System (ADS)
Yanni, Shelagh; Keys, Kevin; Meng, Fan-Rui; Yin, Xiwei; Clair, Tom; Arp, Paul A.
2000-02-01
Hydrological processes and conditions were quantified for the Mersey River Basin (two basins: one exiting below Mill Falls, and one exiting below George Lake), the Roger's Brook Basin, Moosepit Brook, and for other selected locations at and near Kejimkujik National Park in Nova Scotia, Canada, from 1967 to 1990. Addressed variables included precipitation (rain, snow, fog), air temperature, stream discharge, snowpack accumulations, throughfall, soil and subsoil moisture, soil temperature and soil frost, at a monthly resolution. It was found that monthly per hectare stream discharge was essentially independent of catchment area from <20 km2 to more than 1000 km2. The forest hydrology model ForHyM2 was used to simulate monthly rates of stream discharge, throughfall and snowpack water equivalents for mature forest conditions. These simulations were in good agreement with the historical records once the contributions of fog and mist to the area-wide water budget were taken into account, each on a monthly basis. The resulting simulations establish a hydrologically consistent, continuous, comprehensive and partially verified record for basin-wide outcomes for all major hydrological processes and conditions, be these related to stream discharge, soil moisture, soil temperature, snowpack accumulations, soil frost, throughfall, interception and soil percolation.
Shelley, Jacob T; Wiley, Joshua S; Chan, George C Y; Schilling, Gregory D; Ray, Steven J; Hieftje, Gary M
2009-05-01
Two relatively new ambient ionization sources, direct analysis in real time (DART) and the flowing atmospheric-pressure afterglow (FAPA), use direct current, atmospheric-pressure discharges to produce reagent ions for the direct ionization of a sample. Although at a first glance these two sources appear similar, a fundamental study reveals otherwise. Specifically, DART was found to operate with a corona-to-glow transition (C-G) discharge whereas the FAPA was found to operate with a glow-to-arc transition (G-A) discharge. The characteristics of both discharges were evaluated on the basis of four factors: reagent-ion production, response to a model analyte (ferrocene), infrared (IR) thermography of the gas used for desorption and ionization, and spatial emission characteristics. The G-A discharge produced a greater abundance and a wider variety of reagent ions than the C-G discharge. In addition, the discharges yielded different adducts and signal strengths for ferrocene. It was also found that the gas exiting the discharge chamber reached a maximum of 235 degrees C and 55 degrees C for the G-A and C-G discharges, respectively. Finally, spatially resolved emission maps of both discharges showed clear differences for N(2)(+) and O(I). These findings demonstrate that the discharges used by FAPA and DART are fundamentally different and should have different optimal applications for ambient desorption/ionization mass spectrometry (ADI-MS).
Weaver, J. Curtis; Fine, Jason M.
2003-01-01
An understanding of the magnitude and frequency of low-flow discharges is an important part of protecting surface-water resources and planning for municipal and industrial economic expansion. Low-flow characteristics are summarized for 12 continuous-record gaging stations and 44 partial-record measuring sites in the Rocky River basin in North Carolina. Records of discharge collected through the 2002 water year at continuous-record gaging stations and through the 2001 water year at partial-record measuring sites were used. Flow characteristics included in the summary are (1) average annual unit flow; (2) 7Q10 low-flow discharge, the minimum average discharge for a 7-consecutive-day period occurring, on average, once in 10 years; (3) 30Q2 low-flow discharge; (4) W7Q10 low-flow discharge, which is similar to 7Q10 discharge but is based only on flow during the winter months of November through March; and (5) 7Q2 low-flow discharge. The Rocky River basin drains 1,413 square miles (mi2) of the southern Piedmont Province in North Carolina. The Rocky River is about 91 miles long and merges with the Yadkin River in eastern Stanly County to form the Pee Dee River, which discharges into the Atlantic Ocean in South Carolina. Low-flow characteristics compiled for selected sites in the Rocky River basin indicated that the potential for sustained base flows in the upper half of the basin is relatively higher than for streams in the lower half of the basin. The upper half of the basin is underlain by the Charlotte Belt, where streams have been identified as having moderate potentials for sustained base flows. In the lower half of the basin, many streams were noted as having little to no potential for sustained base flows. Much of the decrease in base-flow potential is attributed to the underlying rock types of the Carolina Slate Belt. Of the 19 sites in the basin having minimal (defined as less than 0.05 cubic foot per second) or zero 7Q10 discharges, 18 sites are located in the lower half of the basin underlain by the Carolina Slate Belt. Assessment of these 18 sites indicates that streams that have drainage areas less than about 25 square miles are likely to have minimal or zero 7Q10 discharges. No drainage-area threshold for minimal or zero 7Q10 discharges was identified for the upper half of the basin, which is underlain by the Charlotte Belt. Tributaries to the Rocky River include the West Branch Rocky River (22.8 mi2), Clarke Creek (28.2 mi2), Mallard Creek (41.2 mi2), Coddle Creek (78.8 mi2), Reedy Creek (43.0 mi2), Irish Buffalo/Coldwater Creeks (110 mi2), Dutch Buffalo Creek (99 mi2), Long Creek (200 mi2), Richardson Creek (234 mi2), and Lanes Creek (135 mi2). In the 20-mile reach upstream from the mouth (about 22 percent of the river length), the drainage area increases by 648 mi2, or about 46 percent of the total drainage area as a result of the confluences with Long Creek, Richardson Creek, and Lanes Creek. Low-flow discharge profiles for the Rocky River include 7Q10, 30Q2, W7Q10, and 7Q2 discharges in a continuous profile with contributions from major tributaries included. At the gaging stations above Irish Buffalo Creek and near Stanfield, the 7Q10 discharges are 25.2 and 42.3 cubic feet per second, corresponding to 0.09 and 0.07 cubic feet per second per square mile, respectively. At the gaging station near Norwood, the 7Q10 discharge is 45.8 cubic feet per second, equivalent to 0.03 cubic foot per second per square mile. Low-flow discharge profiles reflect the presence of several major flow diversions in the reaches upstream from Stanfield and an apparent losing reach between the continuous-record gaging stations near Stanfield and Norwood, North Carolina.
Water resources activities, Georgia District, 1986
Casteel, Carolyn A.; Ballew, Mary D.
1987-01-01
The U.S. Geological Survey, through its Water Resources Division , investigates the occurrence, quantity, quality, distribution, and movement of the surface and underground water that composes the Nation 's water resources. Much of the work is a cooperative effort in which planning and financial support are shared by state and local governments and other federal agencies. This report contains a brief description of the water-resources investigations in Georgia in which the Geological Survey participates, and a list of selected references. Water-resources data for the 1985 water year for Georgia consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and groundwater levels. These data include discharge records for 108 gaging stations; water quality for 43 continuous stations, 109 periodic stations, and miscellaneous sites; peak stage and discharge only for 130 crest-stage partial-record stations and 44 miscellaneous sites; and water levels of 27 observation wells. Nineteen Georgia District projects are summarized. (Lantz-PTT)
Water resources data, Idaho, 2002; Volume 1. Great Basin and Snake River basin above King Hill
Brennan, T.S.; Lehmann, A.K.; Campbell, A.M.; O'Dell, I.; Beattie, S.E.
2003-01-01
Water resources data for the 2002 water year for Idaho consists of records of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes and reservoirs; discharge of irrigation diversions; and water levels and water quality of groundwater. The two volumes of this report contain discharge records for 196 stream-gaging stations and 15 irrigation diversions; stage only records for 5 stream-gaging stations; stage only for 6 lakes and reservoirs; contents only for 13 lakes and reservoirs; water-quality for 78 stream-gaging stations and partial record sites, 3 lakes sites, and 383 groundwater wells; and water levels for 425 observation network wells and 900 special project wells. Additional water data were collected at various sites not involved in the systematic data collection program and are published as miscellaneous measurements. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in Idaho, adjacent States, and Canada.
Brennan, T.S.; Lehmann, A.K.; Campbell, A.M.; O'Dell, I.; Beattie, S.E.
2003-01-01
Water resources data for the 2002 water year for Idaho consists of records of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes and reservoirs; discharge of irrigation diversions; and water levels and water quality of groundwater. The two volumes of this report contain discharge records for 196 stream-gaging stations and 15 irrigation diversions; stage only records for 5 stream-gaging stations; stage only for 6 lakes and reservoirs; contents only for 13 lakes and reservoirs; water-quality for 78 stream-gaging stations and partial record sites, 3 lakes sites, and 383 groundwater wells; and water levels for 425 observation network wells and 900 special project wells. Additional water data were collected at various sites not involved in the systematic data collection program and are published as miscellaneous measurements. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in Idaho, adjacent States, and Canada.
Swanson, R Lawrence; Wilson, Robert; Brownawell, Bruce; Willig, Kaitlin
2017-08-15
Failure of the Bay Park Sewage Treatment Plant (STP) during Superstorm Sandy led to adverse effects in the waters of Hempstead Bay, Long Island, NY. These appear to be related to large discharges of partially treated sewage through its primary and auxiliary outfalls. Modeled dilution discharges indicate that sewage infiltrated the bay, remaining up to 10days. Water column impacts included salinity and dissolved oxygen declines, and biological oxygen demand and nitrogen concentration increases. While the STP does not appear to have released fecal coliform, there were elevated levels of enterococci within the bay for a considerable period following the storm, probably from multiple sources. The STP's reduced functioning and associated environmental impacts, even with resilience upgrades, are not conducive to removing the bay from the list of Impaired Water Bodies. The results reinforce the need to transfer the discharge from the existing outfall to the ocean. Copyright © 2017 Elsevier Ltd. All rights reserved.
Fratesi, S.E.; Leonard, V.; Sanford, W.E.
2007-01-01
In order to explore submarine groundwater discharge in the vicinity of karst features that penetrate the confining layer of an offshore, partially confined aquifer, we constructed a three-dimensional groundwater model using the SUTRA (Saturated-Unsaturated TRAnsport) variable-density groundwater flow model. We ran a parameter sensitivity analysis, testing the effects of recharge rates, permeabilities of the aquifer and confining layer, and thickness of the confining layer. In all simulations, less than 20% of the freshwater recharge for the entire model exits through the sinkhole. Recirculated seawater usually accounts for 10-30% of the total outflow from the model. Often, the sinkhole lies seaward of the transition zone and acts as a recharge feature for recirculating seawater. The permeability ratio between aquifer and confining layer influences the configuration of the freshwater wedge the most; as confining layer permeability decreases, the wedge lengthens and the fraction of total discharge exiting through the sinkhole increases. Copyright ?? 2007 IAHS Press.
Relationship Between Locked Modes and Disruptions in the DIII-D Tokamak
NASA Astrophysics Data System (ADS)
Sweeney, Ryan
This thesis is organized into three body chapters: (1) the first use of naturally rotating tearing modes to diagnose intrinsic error fields is presented with experimental results from the EXTRAP T2R reversed field pinch, (2) a large scale study of locked modes (LMs) with rotating precursors in the DIII-D tokamak is reported, and (3) an in depth study of LM induced thermal collapses on a few DIII-D discharges is presented. The amplitude of naturally rotating tearing modes (TMs) in EXTRAP T2R is modulated in the presence of a resonant field (given by the superposition of the resonant intrinsic error field, and, possibly, an applied, resonant magnetic perturbation (RMP)). By scanning the amplitude and phase of the RMP and observing the phase-dependent amplitude modulation of the resonant, naturally rotating TM, the corresponding resonant error field is diagnosed. A rotating TM can decelerate and lock in the laboratory frame, under the effect of an electromagnetic torque due to eddy currents induced in the wall. These locked modes often lead to a disruption, where energy and particles are lost from the equilibrium configuration on a timescale of a few to tens of milliseconds in the DIII-D tokamak. In fusion reactors, disruptions pose a problem for the longevity of the reactor. Thus, learning to predict and avoid them is important. A database was developed consisting of ˜ 2000 DIII-D discharges exhibiting TMs that lock. The database was used to study the evolution, the nonlinear effects on equilibria, and the disruptivity of locked and quasi-stationary modes with poloidal and toroidal mode numbers m = 2 and n = 1 at DIII-D. The analysis of 22,500 discharges shows that more than 18% of disruptions present signs of locked or quasi-stationary modes with rotating precursors. A parameter formulated by the plasma internal inductance li divided by the safety factor at 95% of the toroidal flux, q95, is found to exhibit predictive capability over whether a locked mode will cause a disruption or not, and does so up to hundreds of milliseconds before the disruption. Within 20 ms of the disruption, the shortest distance between the island separatrix and the unperturbed last closed flux surface, referred to as dedge, performs comparably to l i/q95 in its ability to discriminate disruptive locked modes, and it also correlates well with the duration of the locked mode. On average, and within errors, the n=1 perturbed field grows exponentially in the final 50 ms before a disruption, however, the island width cannot discern whether a LM will disrupt or not up to 20 ms before the disruption. A few discharges are selected to analyze the evolution of the electron temperature profile in the presence of multiple coexisting locked modes during partial and full thermal quenches. Partial thermal quenches are often an initial, distinct stage in the full thermal quench caused by radiation, conduction, or convection losses. Here we explore the fundamental mechanism that causes the partial quench. Near the onset of partial thermal quenches, locked islands are observed to align in a unique way, or island widths are observed to grow above a threshold. Energy analysis on one discharge suggests that about half of the energy is lost in the divertor region. In discharges with minimum values of the safety factor above ˜1.2, and with current profiles expected to be classically stable, locked modes are observed to self-stabilize by inducing a full thermal quench, possibly by double tearing modes that remove the pressure gradient across the island, thus removing the neoclassical drive.
NASA Astrophysics Data System (ADS)
Carlo Espinoza, Jhan; Ronchail, Josyane; Loup Guyot, Jean; Junquas, Clementine; Drapeau, Guillaume; Martinez, Jean Michel; Santini, William; Vauchel, Philippe; Lavado, Waldo; Ordoñez, Julio; Espinoza, Raúl
2012-06-01
In this work we document and analyze the hydrological annual cycles characterized by a rapid transition between low and high flows in the Amazonas River (Peruvian Amazon) and we show how these events, which may impact vulnerable riverside residents, are related to regional climate variability. Our analysis is based on comprehensive discharge, rainfall and average suspended sediment data sets. Particular attention is paid to the 2010-11 hydrological year, when an unprecedented abrupt transition from the extreme September 2010 drought (8300 m3 s-1) to one of the four highest discharges in April 2011 (49 500 m3 s-1) was recorded at Tamshiyacu (Amazonas River). This unusual transition is also observed in average suspended sediments. Years with a rapid increase in discharge are characterized by negative sea surface temperature anomalies in the central equatorial Pacific during austral summer, corresponding to a La Niña-like mode. It originates a geopotential height wave train over the subtropical South Pacific and southeastern South America, with a negative anomaly along the southern Amazon and the southeastern South Atlantic convergence zone region. As a consequence, the monsoon flux is retained over the Amazon and a strong convergence of humidity occurs in the Peruvian Amazon basin, favoring high rainfall and discharge. These features are also reported during the 2010-11 austral summer, when an intense La Niña event characterized the equatorial Pacific.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, S.P.; Hedgecock, N.S.
1989-10-01
Personnel from the AFOEHL conducted a waste-water characterization and hazardous-waste technical assistance survey at MAFB from 28 Nov to 9 Dec 1988. The scope of this survey was to characterize the waste-water, address hazardous-waste-management practices, and explore opportunities for hazardous waste minimization. The waste water survey team analyzed the base's industrial effluent, effluent from oil/water separators, and storm water. The team performed a shop-by-shop evaluation of chemical-waste-management practices. Survey results showed that MAFB needs to improve its hazardous-waste-management program. Recommendations for improvement include: (1) Collecting two additional grab samples on separate days from the hospital discharge. Analyze for EPA Methodmore » 601 to determine if the grab sample from the survey gives a true indication of what is being discharged. (2) Locate the source and prevent mercury from the hospital from discharging into the sanitary sewer. (3) Dilute the soaps used for cleaning at the Fuels Lab, Building 7060. (4) Investigate the source of chromium from the Photo Lab. (5) Clean out the sewer system manhole directly downgradient from the Photo Lab. (6) Locate the source of contamination in the West Ditch Outfall. (7) Reconnect the two oil/water separators that discharge into the storm sewerage system. (8) Investigate the source of methylene chloride coming on the base. (9) Investigate the source of mercury at Fuel Cell Repair, building 7005.« less
Effect of drive-through delivery laws on postpartum length of stay and hospital charges.
Liu, Zhimei; Dow, William H; Norton, Edward C
2004-01-01
Postpartum hospital length of stay fell rapidly during the 1980s and 1990s, perhaps due to increased managed care penetration. In response, 32 states enacted early postpartum discharge laws between 1995 and 1997, and a federal law took effect in 1998. We analyze how these laws changed length of stay and hospital charges, using a national discharge database. Difference-in-differences models show that the laws increased both length of stay and hospital charges, but the magnitude of this effect is much smaller than has been estimated in previously reported case studies. Furthermore, we find that effects vary by law details, that ERISA diluted the law effects, and that law effects partially spilled over to unregulated Medicaid births.
Water resources data, Indiana, water year 1982
Miller, R.L.; Hoggatt, R.E.; Nell, G.E.
1983-01-01
Water resources data for the 1982 water year for Indiana consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels in wells. This report contains discharge records for 176 gaging stations, stage and contents for 9 lakes and reservoirs, releases from 8 flood control reservoirs, water quality for 26 gaging stations, and water levels for 87 observation wells. Also included are 71 crest-stage partial-record stations. Additional water data were collected at various sites, not part of the systematic data-collection program, and are published as miscellaneous measurements. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in Indiana.
Water resources data, Indiana, water year 1983
Miller, R.L.; Hoggatt, R.E.; Nell, G.E.
1984-01-01
Water resources data for the 1983 water year for Indiana consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels in wells. This report contains discharge records for 174 gaging stations, stage and contents for 9 lake and reservoirs, releases from 7 flood control reservoirs, water quality for 5 gaging stations, and water levels for 84 observation wells. Also included are 23 crest-stage partial-record stations. Additional water data were collected at various sites, not part of the systematic data-collection program, and are published as miscellaneous measurements. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in Indiana.
NASA Technical Reports Server (NTRS)
Johnsen, R. L.; Cullom, R. R.
1977-01-01
A performance test of several experimental afterburner configurations was conducted with a mixed-flow turbofan engine in an altitude facility. The simulated flight conditions were for Mach 1.4 at two altitudes, 12,190 and 14,630 meters. Turbine discharge temperatures of 889 and 1056 K were used. A production afterburner was tested for comparison. The research afterburners included partial forced mixers with V-gutter flameholders, a carburetted V-gutter flameholder, and a triple ring V-gutter flameholder with four swirl-can fuel mixers. Fuel injection variations were included. Performance data shown include augmented thrust ratio, thrust specific fuel consumption, combustion efficiency, and total pressure drop across the afterburner.
,
1981-01-01
Volume 1 of water resources data for the 1980 water year for California consists of records of stage, discharge, and water quality of streams; stage and contents in lake and reservoirs; and water levels in wells. This report contains discharge records for 174 gaging stations; stage and contents for 18 lakes and reservoirs; water quality for 51 stations; water levels for 165 observation wells. Also included are 9 crest-stage partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
Bowers, J.C.; Butcher, M.T.; Lamb, C.E.; Singer, J.A.; Smith, G.B.
1985-01-01
Water resources data for the 1983 water year for California consists of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 154 gaging stations; stage and contents for 18 lakes and reservoirs; water quality for 20 streams and 18 wells; water levels for 165 observation wells. Also included are 10 crest-stage partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and federal agencies in California.
Bowers, J.C.; Butcher, M.T.; Lamb, C.E.; Singer, J.A.; Smith, G.B.
1984-01-01
Water-resources data for the 1982 water year for California consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 160 gaging stations; stage and contents for 19 lakes and reservoirs; water quality for 20 streams and 20 wells; water levels for 174 observation wells. Also included are 10 crest-stage partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Attebery, C.W.; Zimmer, A.T.; Hedgecock, N.S.
1989-01-01
A waste-water characterization hazardous-waste survey was conducted at Beale AFB by USAFOEHL/ECQ personnel to provide the base with sufficient information to address a State of California Notice of Violation concerning excessive discharges of boron and cyanide from the base sewage-treatment plant (STP). The results of the survey showed that the 9th RTS Precision Photo Lab along with other film-processing organizations were major contributors to the boron and cyanide discharge problems being experienced by the base STP. Maintenance organizations that utilize soaps and detergents that contain boron and cyanide also contributed to the problem.
Characterization factors for thermal pollution in freshwater aquatic environments.
Verones, Francesca; Hanafiah, Marlia Mohd; Pfister, Stephan; Huijbregts, Mark A J; Pelletier, Gregory J; Koehler, Annette
2010-12-15
To date the impact of thermal emissions has not been addressed in life cycle assessment despite the narrow thermal tolerance of most aquatic species. A method to derive characterization factors for the impact of cooling water discharges on aquatic ecosystems was developed which uses space and time explicit integration of fate and effects of water temperature changes. The fate factor is calculated with a 1-dimensional steady-state model and reflects the residence time of heat emissions in the river. The effect factor specifies the loss of species diversity per unit of temperature increase and is based on a species sensitivity distribution of temperature tolerance intervals for various aquatic species. As an example, time explicit characterization factors were calculated for the cooling water discharge of a nuclear power plant in Switzerland, quantifying the impact on aquatic ecosystems of the rivers Aare and Rhine. The relative importance of the impact of these cooling water discharges was compared with other impacts in life cycle assessment. We found that thermal emissions are relevant for aquatic ecosystems compared to other stressors, such as chemicals and nutrients. For the case of nuclear electricity investigated, thermal emissions contribute between 3% and over 90% to Ecosystem Quality damage.
NASA Astrophysics Data System (ADS)
Li, Jianhui; Xing, Lidan; Zhang, Liping; Yu, Le; Fan, Weizhen; Xu, Mengqing; Li, Weishan
2016-08-01
Self-discharge behavior of layered lithium-rich oxide as cathode of lithium ion battery in a carbonated-based electrolyte is understood, and a simple boron-containing compound, trimethyl borate (TMB), is used as an electrolyte additive to suppress this self-discharge. It is found that layered lithium-rich oxide charged under 4.8 V in additive-free electrolyte suffers severe self-discharge and TMB is an effective electrolyte additive for self-discharge suppression. Physical characterizations from XRD, SEM, TEM, XPS and ICP-MS demonstrate that the crystal structure of the layered lithium-rich oxide collapses due to the chemical interaction between the charged oxide and electrolyte. When TMB is applied, the structural integrity of the oxide is maintained due to the protective cathode film generated from the preferential oxidation of TMB.
Characterization of Early Partial Seizure Onset: Frequency, Complexity and Entropy
Jouny, Christophe C.; Bergey, Gregory K.
2011-01-01
Objective A clear classification of partial seizures onset features is not yet established. Complexity and entropy have been very widely used to describe dynamical systems, but a systematic evaluation of these measures to characterize partial seizures has never been performed. Methods Eighteen different measures including power in frequency bands up to 300Hz, Gabor atom density (GAD), Higuchi fractal dimension (HFD), Lempel-Ziv complexity, Shannon entropy, sample entropy, and permutation entropy, were selected to test sensitivity to partial seizure onset. Intracranial recordings from forty-five patients with mesial temporal, neocortical temporal and neocortical extratemporal seizure foci were included (331 partial seizures). Results GAD, Lempel-Ziv complexity, HFD, high frequency activity, and sample entropy were the most reliable measures to assess early seizure onset. Conclusions Increases in complexity and occurrence of high-frequency components appear to be commonly associated with early stages of partial seizure evolution from all regions. The type of measure (frequency-based, complexity or entropy) does not predict the efficiency of the method to detect seizure onset. Significance Differences between measures such as GAD and HFD highlight the multimodal nature of partial seizure onsets. Improved methods for early seizure detection may be achieved from a better understanding of these underlying dynamics. PMID:21872526
NASA Technical Reports Server (NTRS)
Woods, Stephen S.; Saulsberry, Regor
2010-01-01
Pyrotechnic thruster pressure cartridges (TPCs) are used for aeroshell separation on a new NASA crew launch vehicle. Nondestructive evaluation (NDE) during TPC acceptance testing indicated that internal assemblies moved during shock and vibration testing due to an internal bond anomaly. This caused concerns that the launch environment might produce the same movement and release propellant grains that might be prematurely ignited through impact or through electrostatic discharge (ESD) as grains vibrated against internal surfaces. Since a new lot could not be fabricated in time, a determination had to be made as to whether the lot was acceptable to fly. This paper discusses the ESD evaluation and a separate paper addresses the impact problem. A challenge to straight forward assessment existed due to the unavailability of triboelectric data characterizing the static charging characteristics of the propellants within the TPC. The approach examined the physical limitations for charge buildup within the TPC system geometry and evaluated it for discharge under simulated vibrations used to qualify components for launch. A facsimile TPC was fabricated using SS 301 for the case and surrogate worst case materials for the propellants based on triboelectric data. System discharge behavior was evaluated by applying high voltage to the point of discharge in air and by placing worst case charge accumulations within the facsimile TPC and forcing discharge. The facsimile TPC contained simulated propellant grains and lycopodium, a well characterized indicator for static discharge in dust explosions, and was subjected to accelerations equivalent to the maximum accelerations possible during launch. The magnitude of charge generated within the facsimile TPC system was demonstrated to lie in a range of 100 to 10,000 times smaller than the spark energies measured to ignite propellant grains in industry standard discharge tests. The test apparatus, methodology, and results are described in this paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRouen, L.R.; Hann, R.W.; Casserly, D.M.
1983-02-01
This project centers around the Strategic Petroleum Site (SPR) known as the West Hackberry salt dome which located in southwestern Louisiana, and which is designed to store 241 million barrels of crude oil. Oil storage caverns are formed by injecting water into salt deposits, and pumping out the resulting brine. Studies described in this report were designed as follow-on studies to three months of pre-discharge characterization work, and include data collected during the first year of brine leaching operations. The objectives were to: (1) characterize the environment in terms of physical, chemical and biological attributes; (2) determine if significant adversemore » changes in ecosystem productivity and stability of the biological community are occurring as a result of brine discharge; and (3) determine the magnitude of any change observed. Volume V contains appendices for the following: supporting data for estuarine hydrology and hydrography; supporting data analysis of discharge plume; supporting data for water and sediment chemistry; CTD/DO and pH profiles during biological monitoring; supporting data for nekton; and supporting data for data management.« less
High Voltage Testing. Volume 2. Specifications and Test Procedures
1982-08-01
the greatest impact on the initial assumption and criteria developed in the published criteria documents include: dielectric withstanding voltage...3382-75 Measurement of Energy and Integrated Charge Transfer Due to Partial Discharges (Corona) Using Bridge Techniques. ASTM-D 3426 - Dielectric... Energy (NEMA Publication No. WC 7-1971). NEMA Publication No. 109 - AIEE-EEI-NEMA Standard Basic Insulation Level. 092-57 - Method of Test for Flash and
Mattos-Guaraldi, A L; Damasco, P V; Gomes, D L R; Melendez, M G; Santos, L S; Marinelli, R S; Napoleão, F; Sabbadini, P S; Santos, C S; Moreira, L O; Hirata, R
2011-11-01
We report a case of concurrent diphtheria and infectious mononucleosis in an 11-year-old Brazilian child. Two days after specific treatment for diphtheria was started the patient was discharged following clinical recovery. This case highlights the difficulties in the clinical diagnosis of diphtheria in partially immunized individuals, and for the management and control of diphtheria in developing countries.
NASA Astrophysics Data System (ADS)
Gong, L.
2013-12-01
Large-scale hydrological models and land surface models are by far the only tools for accessing future water resources in climate change impact studies. Those models estimate discharge with large uncertainties, due to the complex interaction between climate and hydrology, the limited quality and availability of data, as well as model uncertainties. A new purely data-based scale-extrapolation method is proposed, to estimate water resources for a large basin solely from selected small sub-basins, which are typically two-orders-of-magnitude smaller than the large basin. Those small sub-basins contain sufficient information, not only on climate and land surface, but also on hydrological characteristics for the large basin In the Baltic Sea drainage basin, best discharge estimation for the gauged area was achieved with sub-basins that cover 2-4% of the gauged area. There exist multiple sets of sub-basins that resemble the climate and hydrology of the basin equally well. Those multiple sets estimate annual discharge for gauged area consistently well with 5% average error. The scale-extrapolation method is completely data-based; therefore it does not force any modelling error into the prediction. The multiple predictions are expected to bracket the inherent variations and uncertainties of the climate and hydrology of the basin. The method can be applied in both un-gauged basins and un-gauged periods with uncertainty estimation.
Flow resistance and hydraulic geometry in contrasting reaches of a bedrock channel
NASA Astrophysics Data System (ADS)
Ferguson, R. I.; Sharma, B. P.; Hardy, R. J.; Hodge, R. A.; Warburton, J.
2017-03-01
Assumptions about flow resistance in bedrock channels have to be made for mechanistic modeling of river incision, paleoflood estimation, flood routing, and river engineering. Field data on bedrock flow resistance are very limited and calculations generally use standard alluvial-river assumptions such as a fixed value of Manning's n. To help inform future work, we measured how depth, velocity, and flow resistance vary with discharge in four short reaches of a small bedrock channel, one with an entirely rock bed and the others with 20-70% sediment cover, and in the alluvial channel immediately upstream. As discharge and submergence increase in each of the partly or fully alluvial reaches there is a rapid increase in velocity and a strong decline in both n and the Darcy-Weisbach friction factor f. The bare-rock reach follows a similar trend from low to medium discharge but has increasing resistance at higher discharges because of the macroroughness of its rock walls. Flow resistance at a given discharge differs considerably between reaches and is highest where the partial sediment cover is coarsest and most extensive. Apart from the effect of rough rock walls, the flow resistance trends are qualitatively consistent with logarithmic and variable-power equations and with nondimensional hydraulic geometry, but quantitative agreement using sediment D84 as the roughness height is imperfect.
NASA Astrophysics Data System (ADS)
Vanpeene, V.; Etiemble, A.; Bonnin, A.; Maire, E.; Roué, L.
2017-05-01
The evolution of the three-dimensional (3D) morphology of a Si-based electrode upon cycling (1st discharge, 1st charge and 2nd discharge) is studied by in-situ synchrotron X-ray tomography. The Si-based electrode is constituted of silicon/carbon black/carboxymethylcellulose (Si/CB/CMC) embedded in a commercial carbon fiber paper, acting as a flexible 3D current collector. Its initial areal discharge capacity is 4.9 mAh cm-2. A reconstructed volume of 293 × 293 × 137 μm3 is analyzed with a resolution of ∼0.3 μm. Three phases are identified: (i) the solid phase (C fibers + Si + CB + CMC), (ii) the electrolyte phase (pores filled with electrolyte) and (iii) the gas phase (electrolyte-free pores). Their respective volume fraction, size distribution and connectivity, and also the dimensional changes of the electrode along the three axes are quantified during cycling. At the beginning of the 1st discharge (lithiation), the formation of gas channels attributed to the reductive electrolyte decomposition is observed. During the 1st charge, large cracks are formed through the electrode, which reclose during the subsequent discharge. The electrode expansion/contraction due to the Si volume change is partially irreversible, occurs mainly in the transverse direction and is much larger in the bottom part of the electrode.
Brown, Larry R.; Bauer, Marissa L.
2010-01-01
Alteration of natural flow regimes is generally acknowledged to have negative effects on native biota; however, methods for defining ecologically appropriate flow regimes in managed river systems are only beginning to be developed. Understanding how past and present water management has affected rivers is an important part of developing such tools. In this paper, we evaluate how existing hydrologic infrastructure and management affect streamflow characteristics of rivers in the Central Valley, California and discuss those characteristics in the context of habitat requirements of native and alien fishes. We evaluated the effects of water management by comparing observed discharges with estimated discharges assuming no water management ("full natural runoff"). Rivers in the Sacramento River drainage were characterized by reduced winter–spring discharges and augmented discharges in other months. Rivers in the San Joaquin River drainage were characterized by reduced discharges in all months but particularly in winter and spring. Two largely unaltered streams had hydrographs similar to those based on full natural runoff of the regulated rivers. The reduced discharges in the San Joaquin River drainage streams are favourable for spawning of many alien species, which is consistent with observed patterns of fish distribution and abundance in the Central Valley. However, other factors, such as water temperature, are also important to the relative success of native and alien resident fishes. As water management changes in response to climate change and societal demands, interdisciplinary programs of research and monitoring will be essential for anticipating effects on fishes and to avoid unanticipated ecological outcomes.
Hydrogeological characterization of peculiar Apenninic springs
NASA Astrophysics Data System (ADS)
Cervi, F.; Marcaccio, M.; Petronici, F.; Borgatti, L.
2014-09-01
In the northern Apennines of Italy, springs are quite widespread over the slopes. Due to the outcropping of low-permeability geologic units, they are generally characterized by low-yield capacities and high discharge variability during the hydrologic year. In addition, low-flow periods (discharge lower than 1 Ls-1) reflect rainfall and snowmelt distribution and generally occur in summer seasons. These features strongly condition the management for water-supply purposes, making it particularly complex. The "Mulino delle Vene" springs (420 m a.s.l., Reggio Emilia Province, Italy) are one of the largest in the Apennines for mean annual discharge and dynamic storage and are considered as the main water resource in the area. They flow out from several joints and fractures at the bottom of an arenite rock mass outcrop in the vicinity of the Tresinaro River. To date, these springs have not yet been exploited, as the knowledge about the hydrogeological characteristics of the aquifer and their hydrological behaviour is not fully achieved. This study aims to describe the recharge processes and to define the hydrogeological boundaries of the aquifer. It is based on river and spring discharge monitoring and groundwater balance assessment carried out during the period 2012-2013. Results confirm the effectiveness of the approach, as it allowed the total aliquot of discharge of the springs to be assessed. Moreover, by comparing the observed discharge volume with the one calculated with the groundwater balance, the aquifer has been identified with the arenite slab (mean altitude of 580 m a.s.l.), extended about 5.5 km2 and located 1 km west of the monitored springs.
Electrical, thermal and abusive tests on lithium thionyl chloride cells
NASA Technical Reports Server (NTRS)
Frank, H. A.
1980-01-01
Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.
Electrical, thermal and abusive tests on lithium thionyl chloride cells
NASA Astrophysics Data System (ADS)
Frank, H. A.
1980-04-01
Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.
Estimating river discharge uncertainty by applying the Rating Curve Model
NASA Astrophysics Data System (ADS)
Barbetta, S.; Melone, F.; Franchini, M.; Moramarco, T.
2012-04-01
The knowledge of the flow discharge at a river site is necessary for planning and management of water resources as well as for monitoring and real-time forecasting purposes when significant flood events occur. In the hydrological practice, the operational discharge measurement in medium and large rivers is mostly based on indirect approaches by converting the observed stage into discharge values using steady-flow rating curves. However, the stage-discharge relationship can be unknown for hydrometric sections where flow velocity measurements, particularly during high floods, are not available. To overcome this issue, a simplified approach named Rating Curve Model (RCM) and proposed by Moramarco et al. (Moramarco, T., Barbetta, S., F. Melone, F. & Singh, V.P., Relating local stage and remote discharge with significant lateral inflow, J. Hydrol. Engng ASCE, 10[1], 58?69, 2005) can be conveniently used. RCM turned out able to assess, with a high level of accuracy, the discharge hydrograph at a river site where only the stage is monitored while the flow is recorded at a different section along the river, even when significant lateral flows occur. The simple structure of the model is depending on three parameters of which two can be considered characteristic of the river reach and one of the wave travel time of floods. Considering that RCM well lends itself to predict the stage-discharge relationship at a river site wherein only stages are recorded, an uncertainty analysis on river discharge estimate is of interest for the hydrological practice definitely. To this aim, the uncertainty characterizing the RCM outcomes is addressed in this work by considering two different procedures based on the Monte Carlo approach and the Generalized Likelihood Uncertainty Estimation (GLUE) method, respectively. The statistical distribution of parameters is found and a random re-sampling of parameters is done for assessing the 90% confidence interval (CI) of discharge estimates. In particular, for the latter approach the Nash-Sutcliffe coefficient is used as likelihood measure. Two equipped river reaches of the Upper-Middle Tiber River basin, central Italy, are investigated as case studies. The results provided by the selected methodologies are discussed and compared showing that all the computed CIs are satisfied in term of percentage of included observed discharges with similar percentages characterizing the bands assessed by both Monte Carlo approach and GLUE procedure.
Nehme, Z; Andrew, E; Bernard, S; Smith, K
2014-09-01
Success rates from cardiopulmonary resuscitation (CPR) are often quantified by Utstein-style outcome reports in populations who receive an attempted resuscitation. In some cases, evidence of futility is ascertained after a partial resuscitation attempt has been administered, and these cases reduce the overall effectiveness of CPR. We examine the impact of partial resuscitation attempts on the reported outcomes of out-of-hospital cardiac arrest (OHCA) in Victoria, Australia. Between 2002 and 2012, 34,849 adult OHCA cases of presumed cardiac aetiology were included from the Victorian Ambulance Cardiac Arrest Registry. Resuscitation attempts lasting ≤10min in cases which died on scene were defined as a partial resuscitation. We used logistic regression to identify factors associated with a partial resuscitation attempt in the emergency medical service (EMS) treated population. Survival outcomes with and without partial resuscitations were compared across included years. The proportion of partial resuscitations in the overall EMS treated population increased significantly from 8.6% in 2002 to 18.8% in 2012 (p for trend<0.001), and were largely supported by documented evidence of irreversible death. Partial resuscitations were independently associated with older age, female gender, initial non-shockable rhythm, prolonged downtime, and lower skill level of EMS personnel. Selectively excluding partial resuscitations increased event survival by 7.6% (95% CI 4.1-11.2%), and survival to hospital discharge increased by 3.1% (95% CI 0.5-5.7%) in 2012 (p<0.001 for both). In our EMS system, evidence of futility was often identified after the commencement of a partial resuscitation attempt. Excluding these events from OHCA outcome reports may better reflect the overall effectiveness of CPR. Crown Copyright © 2014. Published by Elsevier Ireland Ltd. All rights reserved.
Phenomenology of hallucinations, illusions, and delusions as part of seizure semiology.
Kasper, B S; Kasper, E M; Pauli, E; Stefan, H
2010-05-01
In partial epilepsy, a localized hypersynchronous neuronal discharge evolving into a partial seizure affecting a particular cortical region or cerebral subsystem can give rise to subjective symptoms, which are perceived by the affected person only, that is, ictal hallucinations, illusions, or delusions. When forming the beginning of a symptom sequence leading to impairment of consciousness and/or a classic generalized seizure, these phenomena are referred to as an epileptic aura, but they also occur in isolation. They often manifest in the fully awake state, as part of simple partial seizures, but they also can be associated to different degrees of disturbed consciousness. Initial ictal symptoms often are closely related to the physiological functions of the cortical circuit involved and, therefore, can provide localizing information. When brain regions related to sensory integration are involved, the seizure discharge can cause specific kinds of hallucinations, for example, visual, auditory, gustatory, olfactory, and cutaneous sensory sensations. In addition to these elementary sensory perceptions, quite complex hallucinations related to a partial seizure can arise, for example, perception of visual scenes or hearing music. By involving psychic and emotional spheres of human perception, many seizures also give rise to hallucinatory emotional states (e.g., fear or happiness) or even more complex hallucinations (e.g., visuospatial phenomena), illusions (e.g., déjà vu, out-of-body experience), or delusional beliefs (e.g., identity change) that often are not easily recognized as epileptic. Here we suggest a classification into elementary sensory, complex sensory, and complex integratory seizure symptoms. Epileptic hallucinations, illusions, and delusions shine interesting light on the physiology and functional anatomy of brain regions involved and their functions in the human being. This article, in which 10 cases are described, introduces the fascinating phenomenology of subjective seizure symptoms. Copyright (c) 2010 Elsevier Inc. All rights reserved.
de Andrade, James N B M; Christopher Orton, E; Boon, June; Nishimori, Celina T D; Olivaes, Claudio; Camacho, Aparecido A
2011-09-01
To report the outcome of partial external mitral annuloplasty in dogs with congestive heart failure (CHF) due to mitral regurgitation caused by myxomatous mitral valve degeneration (MMVD). Nine client-owned dogs with CHF due to mitral regurgitation caused by MMVD. Surgery consisted of a double row of pledget-butressed continuous suture lines placed into the left ventricle parallel and just ventral to the atrioventricular groove between the subsinuosal branch of the left circumflex coronary artery and the paraconal branch of the left coronary artery. Two dogs died during surgery because of severe hemorrhage. Two dogs died 12 and 36 h after surgery because of acute myocardial infarction. Three dogs were euthanized 2 and 4 weeks after surgery because of progression of CHF, 1 was euthanized 30 days after surgery for non-cardiac disease, and 1 survived for 48 months. In the 5 dogs that survived to discharge there was no significant change in the left atrium to aortic ratio with surgery (3.6 ± 0.56 before surgery; 3.1 ± 0.4 after surgery; p = 0.182), and no significant change in mitral regurgitant fraction in 4 dogs in which this measurement was made (78.7 ± 2.0% before surgery; 68.7 ± 7.5% after surgery; p = 0.09). Partial external mitral annuloplasty in dogs with CHF due to MMVD was associated with high perioperative mortality and most dogs that survived to discharge failed to show clinically relevant palliation from this procedure. Consequently, partial external mitral annuloplasty is not a viable option for dogs with mitral regurgitation due to MMVD that has progressed to the stage of CHF. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Lamb, Michael P.; Brun, Fanny; Fuller, Brian M.
2017-09-01
Steep mountain streams have higher resistance to flow and lower sediment transport rates than expected by comparison with low gradient rivers, and often these differences are attributed to reduced near-bed flow velocities and stresses associated with form drag on channel forms and immobile boulders. However, few studies have directly measured drag and lift forces acting on bed sediment for shallow flows over coarse sediment, which ultimately control sediment transport rates and grain-scale flow resistance. Here we report on particle lift and drag force measurements in flume experiments using a planar, fixed cobble bed over a wide range of channel slopes (0.004 < S < 0.3) and water discharges. Drag coefficients are similar to previous findings for submerged particles (CD ˜ 0.7) but increase significantly for partially submerged particles. In contrast, lift coefficients decrease from near unity to zero as the flow shallows and are strongly negative for partially submerged particles, indicating a downward force that pulls particles toward the bed. Fluctuating forces in lift and drag decrease with increasing relative roughness, and they scale with the depth-averaged velocity squared rather than the bed shear stress. We find that, even in the absence of complex bed topography, shallow flows over coarse sediment are characterized by high flow resistance because of grain drag within a roughness layer that occupies a significant fraction of the total flow depth, and by heightened critical Shields numbers and reduced sediment fluxes because of reduced lift forces and reduced turbulent fluctuations.
Assessing the effects of non-point source pollution on American Samoa's coral reef communities.
Houk, Peter; Didonato, Guy; Iguel, John; Van Woesik, Robert
2005-08-01
Surveys were completed on Tutuila Island, American Samoa, to characterize reef development and assess the impacts of non-point source pollution on adjacent coral reefs at six sites. Multivariate analyses of benthic and coral community data found similar modern reef development at three locations; Aoa, Alofau, and Leone. These sites are situated in isolated bays with gentle sloping foundations. Aoa reefs had the highest estimates of crustose coralline algae cover and coral species richness, while Leone and Alofau showed high abundances of macroalgae and Porites corals. Aoa has the largest reef flat between watershed discharge and the reef slope, and the lowest human population density. Masefau and Fagaalu have a different geomorphology consisting of cemented staghorn coral fragments and steep slopes, however, benthic and coral communities were not similar. Benthic data suggest Fagaalu is heavily impacted compared with all other sites. Reef communities were assessed as bio-criteria indicators for waterbody health, using the EPA aquatic life use support designations of (1) fully supportive, (2) partially supportive, and (3) non-supportive for aquatic life. All sites resulted in a partially supportive ranking except Fagaalu, which was non-supportive. The results of this rapid assessment based upon relative benthic community measures are less desirable than long-term dataset analyses from monitoring programs, however it fills an important role for regulatory agencies required to report annual waterbody assessments. Future monitoring sites should be established to increase the number of replicates within each geological and physical setting to allow for meaningful comparisons along a gradient of hypothesized pollution levels.
Frømyr, Tomas-Roll; Bourgeaux-Goget, Marie; Hansen, Finn Knut
2015-05-01
A method has been developed to characterize the dispersion of multi-wall carbon nanotubes in water using a disc centrifuge for the detection of individual carbon nanotubes, residual aggregates, and contaminants. Carbon nanotubes produced by arc-discharge have been measured and compared with carbon nanotubes produced by chemical vapour deposition. Studies performed on both pristine (see text) arc-discharge nanotubes is rather strong and that high ultra-sound intensity is required to achieve complete dispersion of carbon nanotube bundles. The logarithm of the mode of the particle size distribution of the arc-discharge carbon nanotubes was found to be a linear function of the logarithm of the total ultrasonic energy input in the dispersion process.
NASA Astrophysics Data System (ADS)
Xu, S. J.; Zhang, Y. H.; Yu, Z.; Yao, J.; Zhang, Z. T.
2013-03-01
The streamer regime of pin-to-plane dielectric barrier discharge in air was studied by means of fast photography, electrical measurement and photoelectricity. The fast photographs of positive streamer were obtained by CCD camera with micro lens. The exposure time is one microseconds. The images illustrate that the streamer is non-axisymmetric because of some random factors, such as surface charge position, space charge distribution, gas liquidity and so on. In fact, the streamer propagates along bend discharge channel. The bending degree increases with the electric field strengthen. By surveying a mass of images, the diameter of streamer, height of surface charge effect and scope of surface charge was estimate used to describe the shape of streamer.
NASA Astrophysics Data System (ADS)
Laurent, Morgane; Desjardins, Edouard; Meichelboeck, Maximilian; Naudé, Nicolas; Stafford, Luc; Gherardi, Nicolas; Laroche, Gaétan
2017-11-01
The influence of the input voltage frequency (35 and 150 kHz), interelectrode gap (1 and 2 mm) and precursor concentration (250, 350, and 450 ppm) on the electron temperature (T e), number density of metastable Ar atoms (n(Ar m )), and discharge current density (proportional to the electron density ne) is studied in an argon-ethyl lactate dielectric barrier discharge (DBD). An argon-ammonia Penning mixture is also considered as reference. These results are correlated to the chemistry (XPS, IR) and topography (AFM) of the ethyl-lactate-based plasma polymer coatings. Low T e values from 0.3 to 0.5 eV were obtained for all discharges. This observation, in addition to resemblances with the Ar-NH3 mixture, suggested that the ionization kinetics of ethyl lactate-based discharges is driven by Penning reactions. Among the investigated parameters, the dissipated power obtained through changes of the excitation frequency had the largest impact on both the coatings properties and the discharge behavior.
Cloning and Partial Characterization of an Aniline Metabolic Pathway (Preprint)
1995-08-03
of aniline to organic acids. The pathway resides on a 20.66 kb BamH1 fragment, and is induced by a broad range of substituted anilines, with para ...methyl substitutions, with preference to additions in the meta and para positions. Metabolism of aniline in CIT1 is initiated by aniline, 1,2...metabolism in E.coli, expressing the cloned pathway was confirmed using HPLC . Cloning, Partial Characterization, Aniline Metabolic Pathway U U
Microstructural characterization of catalysis product of nanocement based materials: A review
NASA Astrophysics Data System (ADS)
Sutan, Norsuzailina Mohamed; Izaitul Akma Ideris, Nur; Taib, Siti Noor Linda; Lee, Delsye Teo Ching; Hassan, Alsidqi; Kudnie Sahari, Siti; Mohamad Said, Khairul Anwar; Rahman Sobuz, Habibur
2018-03-01
Cement as an essential element for cement-based products contributed to negative environmental issues due to its high energy consumption and carbon dioxide emission during its production. These issues create the need to find alternative materials as partial cement replacement where studies on the potential of utilizing silica based materials as partial cement replacement come into picture. This review highlights the effectiveness of microstructural characterization techniques that have been used in the studies that focus on characterization of calcium hydroxide (CH) and calcium silicate hydrate (C-S-H) formation during hydration process of cement-based product incorporating nano reactive silica based materials as partial cement replacement. Understanding the effect of these materials as cement replacement in cement based product focusing on the microstructural development will lead to a higher confidence in the use of industrial waste as a new non-conventional material in construction industry that can catalyse rapid and innovative advances in green technology.
This issue of Technology News and Trends highlights strategies and tools for characterizing or monitoring remediation of sites with contaminated sediment. Addressing these sites often relies upon dynamic workplans that involve more efficient, cost-effective, and practical methods...
Exploring SWOT discharge algorithm accuracy on the Sacramento River
NASA Astrophysics Data System (ADS)
Durand, M. T.; Yoon, Y.; Rodriguez, E.; Minear, J. T.; Andreadis, K.; Pavelsky, T. M.; Alsdorf, D. E.; Smith, L. C.; Bales, J. D.
2012-12-01
Scheduled for launch in 2019, the Surface Water and Ocean Topography (SWOT) satellite mission will utilize a Ka-band radar interferometer to measure river heights, widths, and slopes, globally, as well as characterize storage change in lakes and ocean surface dynamics with a spatial resolution ranging from 10 - 70 m, with temporal revisits on the order of a week. A discharge algorithm has been formulated to solve the inverse problem of characterizing river bathymetry and the roughness coefficient from SWOT observations. The algorithm uses a Bayesian Markov Chain estimation approach, treats rivers as sets of interconnected reaches (typically 5 km - 10 km in length), and produces best estimates of river bathymetry, roughness coefficient, and discharge, given SWOT observables. AirSWOT (the airborne version of SWOT) consists of a radar interferometer similar to SWOT, but mounted aboard an aircraft. AirSWOT spatial resolution will range from 1 - 35 m. In early 2013, AirSWOT will perform several flights over the Sacramento River, capturing river height, width, and slope at several different flow conditions. The Sacramento River presents an excellent target given that the river includes some stretches heavily affected by management (diversions, bypasses, etc.). AirSWOT measurements will be used to validate SWOT observation performance, but are also a unique opportunity for testing and demonstrating the capabilities and limitations of the discharge algorithm. This study uses HEC-RAS simulations of the Sacramento River to first, characterize expected discharge algorithm accuracy on the Sacramento River, and second to explore the required AirSWOT measurements needed to perform a successful inverse with the discharge algorithm. We focus on several specific research questions affecting algorithm performance: 1) To what extent do lateral inflows confound algorithm performance? We examine the ~100 km stretch of river from Colusa, CA to the Yolo Bypass, and investigate how the varying degrees of lateral flows affect algorithm performance. 2) To what extent does a simple slope-area method (i.e. Manning's equation) applied to river reaches accurately describe river discharge? 3) How accurately does the algorithm perform an inversion to accurately describe the river bathymetry and roughness coefficient? Finally, we explore the sensitivity of the algorithm to the number of AirSWOT flights and AirSWOT measurement precision for various river flow scenarios.
NASA Astrophysics Data System (ADS)
Falta, R. W.
2004-05-01
Analytical solutions are developed that relate changes in the contaminant mass in a source area to the behavior of biologically reactive dissolved contaminant groundwater plumes. Based on data from field experiments, laboratory experiments, numerical streamtube models, and numerical multiphase flow models, the chemical discharge from a source region is assumed to be a nonlinear power function of the fraction of contaminant mass removed from the source zone. This function can approximately represent source zone mass discharge behavior over a wide range of site conditions ranging from simple homogeneous systems, to complex heterogeneous systems. A mass balance on the source zone with advective transport and first order decay leads to a nonlinear differential equation that is solved analytically to provide a prediction of the time-dependent contaminant mass discharge leaving the source zone. The solution for source zone mass discharge is coupled semi-analytically with a modified version of the Domenico (1987) analytical solution for three-dimensional reactive advective and dispersive transport in groundwater. The semi-analytical model then employs the BIOCHLOR (Aziz et al., 2000; Sun et al., 1999) transformations to model sequential first order parent-daughter biological decay reactions of chlorinated ethenes and ethanes in the groundwater plume. The resulting semi-analytic model thus allows for transient simulation of complex source zone behavior that is fully coupled to a dissolved contaminant plume undergoing sequential biological reactions. Analyses of several realistic scenarios show that substantial changes in the ground water plume can result from the partial removal of contaminant mass from the source zone. These results, however, are sensitive to the nature of the source mass reduction-source discharge reduction curve, and to the rates of degradation of the primary contaminant and its daughter products in the ground water plume. Aziz, C.E., C.J. Newell, J.R. Gonzales, P. Haas, T.P. Clement, and Y. Sun, 2000, BIOCHLOR Natural Attenuation Decision Support System User's Manual Version 1.0, US EPA Report EPA/600/R-00/008 Domenico, P.A., 1987, An analytical model for multidimensional transport of a decaying contaminant species, J. Hydrol., 91: 49-58. Sun, Y., J.N. Petersen, T.P. Clement, and R.S. Skeen, 1999, A new analytical solution for multi-species transport equations with serial and parallel reactions, Water Resour. Res., 35(1): 185-190.
VRLA Ultrabattery for high-rate partial-state-of-charge operation
NASA Astrophysics Data System (ADS)
Lam, L. T.; Louey, R.; Haigh, N. P.; Lim, O. V.; Vella, D. G.; Phyland, C. G.; Vu, L. H.; Furukawa, J.; Takada, T.; Monma, D.; Kano, T.
The objective of this study is to produce and test the hybrid valve-regulated Ultrabattery designed specifically for hybrid-electric vehicle duty, i.e., high-rate partial-state-of-charge operation. The Ultrabattery developed by CSIRO Energy Technology is a hybrid energy-storage device, which combines an asymmetric supercapacitor, and a lead-acid battery in one unit cells, taking the best from both technologies without the need for extra, expensive electronic controls. The capacitor will enhance the power and lifespan of the lead-acid battery as it acts as a buffer during high-rate discharging and charging. Consequently, this hybrid technology is able to provide and absorb charge rapidly during vehicle acceleration and braking. The work programme of this study is divided into two main parts, namely, field trial of prototype Ultrabatteries in a Honda Insight HEV and laboratory tests of prototype batteries. In this paper, the performance of prototype Ultrabatteries under different laboratory tests is reported. The evaluation of Ultrabatteries in terms of initial performance and cycling performance has been conducted at both CSIRO and Furukawa laboratories. The initial performance of prototype Ultrabatteries, such as capacity, power, cold cranking and self-discharge has been evaluated based upon the US FreedomCAR Battery Test Manual (DOE/ID-11069, October 2003). Results show that the Ultrabatteries meet, or exceed, respective targets of power, available energy, cold cranking and self-discharge set for both minimum and maximum power-assist HEVs. The cycling performance of prototype Ultrabatteries has been evaluated using: (i) simplified discharge and charge profile to simulate the driving conditions of micro-HEV; (ii) 42-V profile to simulate the driving conditions of mild-HEV and (iii) EUCAR and RHOLAB profiles to simulate the driving conditions of medium-HEV. For comparison purposes, nickel-metal-hydride (Ni-MH) cells, which are presently used in the Honda Insight HEV, have also been subjected to some of the above profiles (i.e., simplified discharge and charge profile and EUCAR profile). Although the Ultrabattery and a Ni-MH cell under EUCAR test profile are still on cycling, the outcomes to date show that the performance of these batteries and cells has been at least four times longer than that of the state-of-the art lead-acid cells or batteries. Excitingly, the performance of Ultrabatteries is proven to be comparable with that of the Ni-MH cells.
Preliminary Evaluation of a 10 kW Hall Thruster
NASA Technical Reports Server (NTRS)
Jankovsky, Robert S.; McLean, Chris; McVey, John
1999-01-01
A 10 kW Hall thruster was characterized over a range of discharge voltages from 300-500 V and a range of discharge currents from 15-23 A. This corresponds to power levels from a low of 4.6 kW to a high of 10.7 kW. Over this range of discharge powers, thrust varied from 278 mN to 524 mN, specific impulse ranged from 1644 to 2392 seconds, and efficiency peaked at approximately 59%. A continuous 40 hour test was also undertaken in an attempt to gain insight with regard to long term operation of the engine. For this portion of the testing the thruster was operated at a discharge voltage of 500 V and a discharge current of 20 A. Steady-state temperatures were achieved after 3-5 hrs and very little variation in performance was detected.
Difficulty in clinical identification of neonatal seizures: an EEG monitor study.
Fenichel, G. M.
1987-01-01
Seventeen newborns were monitored for 24 hours using a three-channel ambulatory EEG (A/EEG). All newborns were thought to be having subtle seizures by the nursery staff. Fifteen of the 17 newborns were recorded as having 1-30 clinical seizures during the time of monitoring. Only one newborn had clinically identified seizures associated with A/EEG discharges. The seizures were characterized by eye rolling. Fifty-two episodes (thought to be seizures) of lip smacking, bicycling, jerking, fisting, staring, stiffening, or any combination of the above occurred in eight newborns without an associated discharge on A/EEG. However, two of the eight had seizure discharges at other times, not associated with any clinical manifestation. Seventy-four apnea spells, thought to be possible seizures, occurred in seven newborns. None was associated with discharges on A/EEG, but one of these newborns had 50 A/EEG discharges unrelated to apnea or other clinical manifestations. PMID:3577211
Development summary of a sympathetic discharge CO2 laser for lidar use
NASA Technical Reports Server (NTRS)
Jaenisch, Holger M.; Johnson, R. Barry
1991-01-01
A commercial pulsed sympathetic discharge laser has been characterized and modified for use as a potential lidar. This report summarizes the initial findings and modifications made to the baseline system. The new laser performance is then checked with theory and operational results are presented. The laser has inherent mode instability and high chirp. Several solutions were tried and their results are presented.
Combined Sewer Overflows as a Source of Hormones to Surface Water
NASA Astrophysics Data System (ADS)
Phillips, P.; Chalmers, A.; Gray, J. L.; Foreman, W.; Kolpin, D. W.; Wall, G.; Esposito, K.
2009-12-01
Some sources of hormones to surface water, such as wastewater-treatment-plant (WWTP) effluent, have been well documented, but other sources, particularly wet-weather discharges from combined-sewer-overflows (CSOs), are not well characterized. Flow-weighted composite samples of secondarily treated WWTP effluent and untreated sewage discharges from WWTP inflows and CSO discharges were collected during 12 storms and 6 non-storm conditions from November 2007-December 2008 at the main Burlington Vermont WWTP. Concentrations of many androgens and estrogens were highest in samples from untreated sewage, and lower in samples from treated sewage. For example, concentrations of estriol in CSO samples ranged from 5 to over 100 ng/L (nanograms per liter), but were generally less than 1 ng/L in treated sewage. Many androgens were detected in CSO discharge samples in concentrations ranging from 1 to over 1000 ng/L, but were not detected above 1 ng/L in treated samples. For many of the hormones, including androgens and estriol, CSO discharges comprised over half of the total load discharged by the WWTP, even though annual CSO discharge is less than 10% of the treated plant discharge. These results indicate that untreated discharges during CSO events can be a major source of some hormones and other wastewater compounds to the environment.
Exploration of Gas Discharges with GaAs, GaP and ZnSe Electrodes Under Atmospheric Pressure
NASA Astrophysics Data System (ADS)
Kurt, H. Hilal
2018-03-01
This work reports on the electrical and optical characterization of the atmospheric pressure glow discharge regimes for different semiconductor electrodes made of GaAs, GaP and ZnSe. The discharge cell is driven by DC feeding voltages at a wide pressure range of 0.66-120 kPa in argon and air media for different interelectrode gaps. The discharge phenomena including different stages of discharges such as glow and Townsend breakdown have been examined. In addition, the infrared sensitivities of the semiconducting materials are evaluated in the micro-discharge cell and discharge light emission measurements have been performed. The qualities of the semiconducting electrode samples can be determined by seeking the homogeneity of the discharge light emission for the optoelectronic device applications. Operation of optical devices under atmospheric pressures gives certain advantages for manufacturing of the devices including the material processing and surface treatment procedures. Besides, finite element analyses of the overall experimental system have been performed for the abovementioned semiconductors. The electron densities and potential patterns have been determined on the discharge cell plane between the electrodes. The findings have proven that the electron densities along the plasma cell depend on both the semiconductor type and plasma parameters.
Porubsky, W.P.; Weston, N.B.; Moore, W.S.; Ruppel, C.; Joye, S.B.
2014-01-01
Multiple techniques, including thermal infrared aerial remote sensing, geophysical and geological data, geochemical characterization and radium isotopes, were used to evaluate the role of groundwater as a source of dissolved nutrients, carbon, and trace gases to the Okatee River estuary, South Carolina. Thermal infrared aerial remote sensing surveys illustrated the presence of multiple submarine groundwater discharge sites in Okatee headwaters. Significant relationships were observed between groundwater geochemical constituents and 226Ra activity in groundwater with higher 226Ra activity correlated to higher concentrations of organics, dissolved inorganic carbon, nutrients, and trace gases to the Okatee system. A system-level radium mass balance confirmed a substantial submarine groundwater discharge contribution of these constituents to the Okatee River. Diffusive benthic flux measurements and potential denitrification rate assays tracked the fate of constituents in creek bank sediments. Diffusive benthic fluxes were substantially lower than calculated radium-based submarine groundwater discharge inputs, showing that advection of groundwater-derived nutrients dominated fluxes in the system. While a considerable potential for denitrification in tidal creek bank sediments was noted, in situ denitrification rates were nitrate-limited, making intertidal sediments an inefficient nitrogen sink in this system. Groundwater geochemical data indicated significant differences in groundwater chemical composition and radium activity ratios between the eastern and western sides of the river; these likely arose from the distinct hydrological regimes observed in each area. Groundwater from the western side of the Okatee headwaters was characterized by higher concentrations of dissolved organic and inorganic carbon, dissolved organic nitrogen, inorganic nutrients and reduced metabolites and trace gases, i.e. methane and nitrous oxide, than groundwater from the eastern side. Differences in microbial sulfate reduction, organic matter supply, and/or groundwater residence time likely contributed to this pattern. The contrasting features of the east and west sub-marsh zones highlight the need for multiple techniques for characterization of submarine groundwater discharge sources and the impact of biogeochemical processes on the delivery of nutrients and carbon to coastal areas via submarine groundwater discharge.
Staley, Christopher; Kaiser, Thomas; Gidley, Maribeth L.; Enochs, Ian C.; Jones, Paul R.; Goodwin, Kelly D.; Sinigalliano, Christopher D.
2017-01-01
ABSTRACT Coral reefs are dynamic ecosystems known for decades to be endangered due, in large part, to anthropogenic impacts from land-based sources of pollution (LBSP). In this study, we utilized an Illumina-based next-generation sequencing approach to characterize prokaryotic and fungal communities from samples collected off the southeast coast of Florida. Water samples from coastal inlet discharges, oceanic outfalls of municipal wastewater treatment plants, treated wastewater effluent before discharge, open ocean samples, and coral tissue samples (mucus and polyps) were characterized to determine the relationships between microbial communities in these matrices and those in reef water and coral tissues. Significant differences in microbial communities were noted among all sample types but varied between sampling areas. Contamination from outfalls was found to be the greatest potential source of LBSP influencing native microbial community structure among all reef samples, although pollution from inlets was also noted. Notably, reef water and coral tissue communities were found to be more greatly impacted by LBSP at southern reefs, which also experienced the most degradation during the course of the study. The results of this study provide new insights into how microbial communities from LBSP can impact coral reefs in southeast Florida and suggest that wastewater outfalls may have a greater influence on the microbial diversity and structure of these reef communities than do contaminants carried in runoff, although the influences of runoff and coastal inlet discharge on coral reefs are still substantial. IMPORTANCE Coral reefs are known to be endangered due to sewage discharge and to runoff of nutrients, pesticides, and other substances associated with anthropogenic activity. Here, we used next-generation sequencing to characterize the microbial communities of potential contaminant sources in order to determine how environmental discharges of microbiota and their genetic material may influence the microbiomes of coral reef communities and coastal receiving waters. Runoff delivered through inlet discharges impacted coral microbial communities, but impacts from oceanic outfalls carrying treated wastewater were greater. Geographic differences in the degree of impact suggest that coral microbiomes may be influenced by the microbiological quality of treated wastewater. PMID:28341673
Staley, Christopher; Kaiser, Thomas; Gidley, Maribeth L; Enochs, Ian C; Jones, Paul R; Goodwin, Kelly D; Sinigalliano, Christopher D; Sadowsky, Michael J; Chun, Chan Lan
2017-05-15
Coral reefs are dynamic ecosystems known for decades to be endangered due, in large part, to anthropogenic impacts from land-based sources of pollution (LBSP). In this study, we utilized an Illumina-based next-generation sequencing approach to characterize prokaryotic and fungal communities from samples collected off the southeast coast of Florida. Water samples from coastal inlet discharges, oceanic outfalls of municipal wastewater treatment plants, treated wastewater effluent before discharge, open ocean samples, and coral tissue samples (mucus and polyps) were characterized to determine the relationships between microbial communities in these matrices and those in reef water and coral tissues. Significant differences in microbial communities were noted among all sample types but varied between sampling areas. Contamination from outfalls was found to be the greatest potential source of LBSP influencing native microbial community structure among all reef samples, although pollution from inlets was also noted. Notably, reef water and coral tissue communities were found to be more greatly impacted by LBSP at southern reefs, which also experienced the most degradation during the course of the study. The results of this study provide new insights into how microbial communities from LBSP can impact coral reefs in southeast Florida and suggest that wastewater outfalls may have a greater influence on the microbial diversity and structure of these reef communities than do contaminants carried in runoff, although the influences of runoff and coastal inlet discharge on coral reefs are still substantial. IMPORTANCE Coral reefs are known to be endangered due to sewage discharge and to runoff of nutrients, pesticides, and other substances associated with anthropogenic activity. Here, we used next-generation sequencing to characterize the microbial communities of potential contaminant sources in order to determine how environmental discharges of microbiota and their genetic material may influence the microbiomes of coral reef communities and coastal receiving waters. Runoff delivered through inlet discharges impacted coral microbial communities, but impacts from oceanic outfalls carrying treated wastewater were greater. Geographic differences in the degree of impact suggest that coral microbiomes may be influenced by the microbiological quality of treated wastewater. Copyright © 2017 Staley et al.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRouen, L.R.; Hann, R.W.; Casserly, D.M.
1983-02-01
This project centers around the Strategic Petroleum Site (SPR) known as the West Hackberry salt dome which is located in southwestern Louisiana, and which is designed to store 241 million barrels of crude oil. Oil storage caverns are formed by injecting water into salt deposits, and pumping out the resulting brine. Studies described in this report were designed as follow-on studies to three months of pre-discharge characterization work, and include data collected during the first year of brine leaching operations. The objectives were to: (1) characterize the environment in terms of physical, chemical and biological attributes; (2) determine if significantmore » adverse changes in ecosystem productivity and stability of the biological community are occurring as a result of brine discharge; and (3) determine the magnitude of any change observed. Contents of Volume II include: introduction; physical oceanography; estuarine hydrology and hydrography; analysis of discharge plume; and water and sediment quality.« less
Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU
NASA Technical Reports Server (NTRS)
Deng, Yi; Jeevarajan, Judith; Rehm, Raymond; Bragg, Bobby; Strangways, Brad
2002-01-01
Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.
An investigation of plasma enhanced combustion
NASA Astrophysics Data System (ADS)
Kim, Woo Kyung
This study examines the use of plasma discharges in flame stabilization. Three different types of plasma discharges are applied to a lifted jet diffusion flame in coflow, and evaluated for their abilities to enhance flame stabilization. A single electrode corona discharge (SECD) is found to maintain the flame at a 20 % higher coflow speed than that without the discharge. A dielectric barrier discharge (DBD) results in flame stabilization at up to 50 % higher coflow speed. Finally, an ultra short-pulsed repetitive discharge (USRD) is found to increase the stability limit by nearly ten-fold. The stabilization process is sensitive to the positioning of the discharge in the flow field, and the optimal position of the discharge is mapped into mixture fraction space. The result shows that the local mixture fraction at the optimal position is much leaner than that of a conventional lifted jet flame. Parametric studies are conducted in a plasma-assisted methane/air premixed flame system using USRD. Criteria for optimal electrode selection are suggested. Platinum provides the best result at low frequency operation (< 20 kHz) but tungsten shows better performance at high frequency operation (> 20 kHz). The increase in the flame stability limit is also investigated. The flame stability limit extends from an equivalence ratio of 0.7 to 0.47. Nitric oxide (NO) concentration in the premixed flame is measured. The discharge is a potential source of NO. Under certain conditions, we observed the presence of a cold pre-flame, located between the discharge and the main flame. It is found that the pre-flame partially consumes some NO. The flame kernel structure and ignition mechanism of plasma-assisted premixed combustion are discussed. It is observed that the pre-flame has an abundance of OH radicals. The key physics of the flame ignition is the diffusion of an OH stream (from the pre-flame) into the surrounding combustible mixture to form the main flame. Lastly, the proposed flame kernel structure is numerically validated using the OPPDIF code. The simulation shows that possibly three reaction zones, one pre-flame and two main flames, exist in this flame configuration.
Robbins, I; Lenoir, F; Mathieu, M
1991-04-01
A putative glycogen mobilizing hormone (GMH) from the marine mussel Mytilus edulis L. has been partially characterized. GMH activity is present in the cerebral ganglia and the hemolymph serum and promotes the mobilization of glycogen in isolated glycogen cells. The cerebral GMH is trypsin sensitive and partially heat labile and has an apparent molecular mass of greater than 20 kDa. Following fractionation of cerebral extracts by molecular mass, a second factor, with a molecular mass of ca. 1.5 kDa, was discovered. This factor stimulates post-incubation incorporation of 14C into glycogen in isolated glycogen cells.
Time-resolved processes in a pulsed electrical discharge in argon bubbles in water
NASA Astrophysics Data System (ADS)
Gershman, S.; Belkind, A.
2010-12-01
A phenomenological picture of a pulsed electrical discharge in gas bubbles in water is produced by combining electrical, spectroscopic, and imaging characterization methods. The discharge is generated by applying 1 μ s pulses of 5 to 20 kV between a needle and a disk electrode submerged in water. An Ar gas bubble surrounds the tip of the needle electrode. Imaging, electrical characteristics, and time-resolved optical emission spectroscopic data suggest a fast streamer propagation mechanism and the formation of a plasma channel in the bubble. Comparing the electrical and imaging data for consecutive pulses applied to the bubble at a frequency of 1 Hz indicates that each discharge proceeds as an entirely new process with no memory of the previous discharge aside from the presence of long-lived chemical species, such as ozone and oxygen. Imaging and electrical data show the presence of two discharge events during each applied voltage pulse, a forward discharge near the beginning of the applied pulse depositing charge on the surface of the bubble and a reverse discharge removing the accumulated charge from the water/gas interface when the applied voltage is turned off. The pd value of ~ 300-500 torr cm, the 1 μs long pulse duration, low repetition rate, and unidirectional character of the applied voltage pulses make the discharge process here unique compared to the traditional corona or dielectric barrier discharges.
NASA Astrophysics Data System (ADS)
Sarathi, R.; Giridhar, A. V.; Sethupathi, K.
2011-02-01
The UHF signals are generated due to PD formed by particle movement in liquid nitrogen under AC voltages. The levitation voltage of a particle in liquid nitrogen measured through UHF technique and by conventional PD measurement technique is the same, confirming the sensitivity of UHF technique for identification of PD activity. The frequency content of UHF signal generated due to particle movement in liquid nitrogen, under AC voltages, lies in the range 0.5-1.5 GHz. The characteristics of UHF signal generated due to particle movement between the barrier and high voltage/ground electrode is much similar to the signal generated by particle movement in clean electrode gap. Pseudo resonance phenomena can occur in liquid nitrogen due to particle movement. It is also observed that the partial discharge magnitude, in general, be high when the particle moves between the barrier and high voltage electrode when compared to the barrier and the ground electrode. Percentage of clay in epoxy nanocomposites has not altered the levitation voltage of the particle in the electrode gap. Zero span analysis clearly indicates that pseudo resonance occurs when particle moves (in a short gap) between the barrier and high voltage/ground electrode.
Jiang, J; Ma, G M; Luo, D P; Li, C R; Li, Q M; Wang, W
2014-02-01
Damped AC voltages detection system (DAC) is a productive way to detect the faults in power cables. To solve the problems of large volume, complicated structure and electromagnetic interference in existing switches, this paper developed a compact solid state switch based on electromagnetic trigger, which is suitable for DAC test system. Synchronous electromagnetic trigger of 32 Insulated Gate Bipolar Transistors (IGBTs) in series was realized by the topological structure of single line based on pulse width modulation control technology. In this way, external extension was easily achieved. Electromagnetic trigger and resistor-capacitor-diode snubber circuit were optimized to reduce the switch turn-on time and circular layout. Epoxy encapsulating was chosen to enhance the level of partial discharge initial voltage (PDIV). The combination of synchronous trigger and power supply is proposed to reduce the switch volume. Moreover, we have overcome the drawback of the electromagnetic interference and improved the detection sensitivity of DAC by using capacitor storage energy to maintain IGBT gate driving voltage. The experimental results demonstrated that the solid-state switch, with compact size, whose turn-on time was less than 400 ns and PDIV was more than 65 kV, was able to meet the actual demands of 35 kV DAC test system.
Zhang, Xiaoxing; Cheng, Zheng; Gui, Yingang
2016-07-26
In this study a new built-in ultrahigh frequency (UHF) antenna sensor was designed and applied in a high-voltage switchgear for partial discharge (PD) detection. The casing of the switchgear was initially used as the ground plane of the antenna sensor, which integrated the sensor into the high-voltage switchgear. The Koch snowflake patch was adopted as the radiation patch of the antenna to overcome the disadvantages of common microstrip antennas, and the feed position and the dielectric layer thickness were simulated in detail. Simulation results show that the antenna sensor possessed four resonant points with good impedance matching from 300 MHz to 1000 MHz, and it also presented good multi-frequency performance in the entire working frequency band. PD detection experiments were conducted in the high-voltage switchgear, and the fabricated antenna sensor was effectively built into the high-voltage switchgear. In order to reflect the advantages of the built-in antenna sensor, another external UHF antenna sensor was used as a comparison to simultaneously detect PD. Experimental results demonstrated that the built-in antenna sensor possessed high detection sensitivity and strong anti-interference capacity, which ensured the practicability of the design. In addition, it had more high-voltage switchgear PD detection advantages than the external sensor.
Zhang, Xiaoxing; Cheng, Zheng; Gui, Yingang
2016-01-01
In this study a new built-in ultrahigh frequency (UHF) antenna sensor was designed and applied in a high-voltage switchgear for partial discharge (PD) detection. The casing of the switchgear was initially used as the ground plane of the antenna sensor, which integrated the sensor into the high-voltage switchgear. The Koch snowflake patch was adopted as the radiation patch of the antenna to overcome the disadvantages of common microstrip antennas, and the feed position and the dielectric layer thickness were simulated in detail. Simulation results show that the antenna sensor possessed four resonant points with good impedance matching from 300 MHz to 1000 MHz, and it also presented good multi-frequency performance in the entire working frequency band. PD detection experiments were conducted in the high-voltage switchgear, and the fabricated antenna sensor was effectively built into the high-voltage switchgear. In order to reflect the advantages of the built-in antenna sensor, another external UHF antenna sensor was used as a comparison to simultaneously detect PD. Experimental results demonstrated that the built-in antenna sensor possessed high detection sensitivity and strong anti-interference capacity, which ensured the practicability of the design. In addition, it had more high-voltage switchgear PD detection advantages than the external sensor. PMID:27472331
Yao, Chenguo; Chen, Pan; Huang, Congjian; Chen, Yu; Qiao, Panpan
2013-01-01
The ultra-high-frequency (UHF) method is used to analyze the insulation condition of electric equipment by detecting the UHF electromagnetic (EM) waves excited by partial discharge (PD). As part of the UHF detection system, the UHF sensor determines the detection system performance in signal extraction and recognition. In this paper, a UHF antenna sensor with the fractal structure for PD detection in switchgears was designed by means of modeling, simulation and optimization. This sensor, with a flat-plate structure, had two resonance frequencies of 583 MHz and 732 MHz. In the laboratory, four kinds of insulation defect models were positioned in the testing switchgear for typical PD tests. The results show that the sensor could reproduce the electromagnetic waves well. Furthermore, to optimize the installation position of the inner sensor for achieving best detection performance, the precise simulation model of switchgear was developed to study the propagation characteristics of UHF signals in switchgear by finite-difference time-domain (FDTD) method. According to the results of simulation and verification test, the sensor should be positioned at the right side of bottom plate in the front cabinet. This research established the foundation for the further study on the application of UHF technique in switchgear PD online detection. PMID:24351641