Sample records for partial discharge monitoring

  1. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    NASA Astrophysics Data System (ADS)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  2. Transformer partial discharge monitoring based on optical fiber sensing

    NASA Astrophysics Data System (ADS)

    Wang, Kun; Tong, Xinglin; Zhu, Xiaolong

    2014-06-01

    The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the optical fiber sensing technology, we have done some research on fiber optics Fabry-Perot (FP) sensing which can be useful for the transformer on online partial discharge monitoring. This research aimed at improving the reliability of power system safety monitoring. We have done some work as follows: designing a set for fiber optics FP sensor preparation, according to the fabrication procedure strictly making out the sensors, building a reasonable signal demodulation system for fiber optics FP sensing, doing a preliminary analysis about online partial discharge signal monitoring, including the research on different discharge intensities with the same measuring distance and different measuring distances with the same discharge intensity, and then making a detailed analysis of the experimental results.

  3. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors

    PubMed Central

    Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José

    2016-01-01

    Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique. PMID:27517931

  4. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.

    PubMed

    Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José

    2016-08-10

    Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.

  5. Virtual-Instrument-Based Online Monitoring System for Hands-on Laboratory Experiment of Partial Discharges

    ERIC Educational Resources Information Center

    Karmakar, Subrata

    2017-01-01

    Online monitoring of high-voltage (HV) equipment is a vital tool for early detection of insulation failure. Most insulation failures are caused by partial discharges (PDs) inside the HV equipment. Because of the very high cost of establishing HV equipment facility and the limitations of electromagnetic interference-screened laboratories, only a…

  6. A Modular Approach for Teaching Partial Discharge Phenomenon through Experiment

    ERIC Educational Resources Information Center

    Chatterjee, B.; Dey, D.; Chakravorti, S.

    2011-01-01

    Partial discharge (PD) monitoring is an effective predictive maintenance tool for electrical power equipment. As a result, an understanding of the theory related to PD and the associated measurement techniques is now necessary knowledge for power engineers in their professional life. This paper presents a modular course on PD phenomenon in which…

  7. An all-fiber partial discharge monitoring system based on both intrinsic fiber optic interferometry sensor and fluorescent fiber

    NASA Astrophysics Data System (ADS)

    Yin, Zelin; Zhang, Ruirui; Tong, Jie; Chen, Xi

    2013-12-01

    Partial discharges (PDs) are an electrical phenomenon that occurs within a transformer whenever the voltage stress is sufficient to produce ionization in voids or inclusions within a solid dielectric, at conductor/dielectric interfaces, or in bubbles within liquid dielectrics such as oil; high-frequency transient current discharges will then appear repeatedly and will progressively deteriorate the insulation, ultimately leading to breakdown. Fiber sensor has great potential on the partial discharge detection in high-voltage equipment for its immunity to electromagnetic interference and it can take direct measurement in the high voltage equipment. The energy released in PDs produces a number of effects, resulting in flash, chemical and structural changes and electromagnetic emissions and so on. Acoustic PD detection is based on the mechanical pressure wave emitted from the discharge and fluorescent fiber PD detection is based on the emitted light produced by ionization, excitation and recombination processes during the discharge. Both of the two methods have the shortage of weak anti-interference capacity in the physical environment, like thunder or other sound source. In order to avoid the false report, an all-fiber combined PD detection system of the two methods is developed in this paper. In the system the fluorescent fiber PD sensor is considered as a reference signal, three F-P based PD detection sensors are used to both monitor the PD intensity and calculate the exact position of the discharge source. Considering the wave band of the F-P cavity and the fluorescent probe are quite different, the reflection spectrum of the F-P cavity is in the infrared region, however the fluorescent probe is about 600nm to 700nm, thus the F-P sensor and fluorescent fiber probe can be connected in one fiber and the reflection light can be detected by two different detectors without mutual interference. The all-fiber partial discharge monitoring system not only can detect the PDs but also can ensure the position of the PD source and is of great anti-interference capacity in harsh environment.

  8. Detection of Partial Discharge Sources Using UHF Sensors and Blind Signal Separation

    PubMed Central

    Boya, Carlos; Parrado-Hernández, Emilio

    2017-01-01

    The measurement of the emitted electromagnetic energy in the UHF region of the spectrum allows the detection of partial discharges and, thus, the on-line monitoring of the condition of the insulation of electrical equipment. Unfortunately, determining the affected asset is difficult when there are several simultaneous insulation defects. This paper proposes the use of an independent component analysis (ICA) algorithm to separate the signals coming from different partial discharge (PD) sources. The performance of the algorithm has been tested using UHF signals generated by test objects. The results are validated by two automatic classification techniques: support vector machines and similarity with class mean. Both methods corroborate the suitability of the algorithm to separate the signals emitted by each PD source even when they are generated by the same type of insulation defect. PMID:29140267

  9. Classification of Partial Discharge Signals by Combining Adaptive Local Iterative Filtering and Entropy Features

    PubMed Central

    Morison, Gordon; Boreham, Philip

    2018-01-01

    Electromagnetic Interference (EMI) is a technique for capturing Partial Discharge (PD) signals in High-Voltage (HV) power plant apparatus. EMI signals can be non-stationary which makes their analysis difficult, particularly for pattern recognition applications. This paper elaborates upon a previously developed software condition-monitoring model for improved EMI events classification based on time-frequency signal decomposition and entropy features. The idea of the proposed method is to map multiple discharge source signals captured by EMI and labelled by experts, including PD, from the time domain to a feature space, which aids in the interpretation of subsequent fault information. Here, instead of using only one permutation entropy measure, a more robust measure, called Dispersion Entropy (DE), is added to the feature vector. Multi-Class Support Vector Machine (MCSVM) methods are utilized for classification of the different discharge sources. Results show an improved classification accuracy compared to previously proposed methods. This yields to a successful development of an expert’s knowledge-based intelligent system. Since this method is demonstrated to be successful with real field data, it brings the benefit of possible real-world application for EMI condition monitoring. PMID:29385030

  10. Partial Discharge Spectral Characterization in HF, VHF and UHF Bands Using Particle Swarm Optimization.

    PubMed

    Robles, Guillermo; Fresno, José Manuel; Martínez-Tarifa, Juan Manuel; Ardila-Rey, Jorge Alfredo; Parrado-Hernández, Emilio

    2018-03-01

    The measurement of partial discharge (PD) signals in the radio frequency (RF) range has gained popularity among utilities and specialized monitoring companies in recent years. Unfortunately, in most of the occasions the data are hidden by noise and coupled interferences that hinder their interpretation and renders them useless especially in acquisition systems in the ultra high frequency (UHF) band where the signals of interest are weak. This paper is focused on a method that uses a selective spectral signal characterization to feature each signal, type of partial discharge or interferences/noise, with the power contained in the most representative frequency bands. The technique can be considered as a dimensionality reduction problem where all the energy information contained in the frequency components is condensed in a reduced number of UHF or high frequency (HF) and very high frequency (VHF) bands. In general, dimensionality reduction methods make the interpretation of results a difficult task because the inherent physical nature of the signal is lost in the process. The proposed selective spectral characterization is a preprocessing tool that facilitates further main processing. The starting point is a clustering of signals that could form the core of a PD monitoring system. Therefore, the dimensionality reduction technique should discover the best frequency bands to enhance the affinity between signals in the same cluster and the differences between signals in different clusters. This is done maximizing the minimum Mahalanobis distance between clusters using particle swarm optimization (PSO). The tool is tested with three sets of experimental signals to demonstrate its capabilities in separating noise and PDs with low signal-to-noise ratio and separating different types of partial discharges measured in the UHF and HF/VHF bands.

  11. Shoulder replacement - discharge

    MedlinePlus

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - ...

  12. Development of Partial Discharging Simulation Test Equipment

    NASA Astrophysics Data System (ADS)

    Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu

    2017-12-01

    In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.

  13. Partial Discharge Ultrasound Detection Using the Sagnac Interferometer System

    PubMed Central

    Li, Xiaomin; Gao, Yan; Zhang, Hongjuan; Wang, Dong; Jin, Baoquan

    2018-01-01

    Partial discharge detection is crucial for electrical cable safety evaluation. The ultrasonic signals frequently generated in the partial discharge process contains important characteristic information. However, traditional ultrasonic transducers are easily subject to strong electromagnetic interference in environments with high voltages and strong magnetic fields. In order to overcome this problem, an optical fiber Sagnac interferometer system is proposed for partial discharge ultrasound detection. Optical fiber sensing and time-frequency analysis of the ultrasonic signals excited by the piezoelectric ultrasonic transducer is realized for the first time. The effective frequency band of the Sagnac interferometer system was up to 175 kHz with the help of a designed 10 kV partial discharge simulator device. Using the cumulative histogram method, the characteristic ultrasonic frequency band of the partial discharges was between 28.9 kHz and 57.6 kHz for this optical fiber partial discharge detection system. This new ultrasound sensor can be used as an ideal ultrasonic source for the intrinsically safe detection of partial discharges in an explosive environment. PMID:29734682

  14. Generation and Reduction of NOx on Air-Fed Ozonizers

    NASA Astrophysics Data System (ADS)

    Ehara, Yoshiyasu; Amemiya, Yusuke; Yamamoto, Toshiaki

    A generation and reduction of NOx on air-fed ozonizers using a ferroelectric packed bed reactor have been experimentally investigated. The reactors packed with CaTiO3, SrTiO3 and BaTiO3 pellets are examined for ozone generation. An ac voltage is applied to the reactor to generate partial discharge. Ozone concentration and the different nitrogen oxides at downstream of the packed bed reactor were measured with UV absorption ozone monitor and a Fourier transform infrared spectroscope respectively. The dielectric constant of packed ferroelectric pellets influences the discharge characteristic, ozone and NOx generations are varied by the dielectric constant value. Focusing on a discharge pulse current and maximum discharge magnitude, the ferroelectric packed bed plasma reactors have been evaluated on nitrogen oxide and ozone generated concentrations.

  15. Seismic Monitoring of Bedload Transport in a Steep Mountain Catchment

    NASA Astrophysics Data System (ADS)

    Roth, D. L.; Finnegan, N. J.; Brodsky, E. E.; Turowski, J. M.; Wyss, C. R.; Badoux, A.

    2014-12-01

    Predicting river channel evolution relies on an understanding of when and at what rate coarse sediment moves in a channel. Unfortunately, our predictive abilities are limited by the logistical challenges and potential dangers inherent in current techniques for monitoring sediment transport during flood events, especially in steep, highly active landscapes. However, the use of seismic signals near rivers shows promise as a safe, low-cost method for studying sediment transport in these settings. Seismic signals near rivers are partially generated by both water turbulence and bedload sediment particles impacting the river bed during transport. Here, we attempt to isolate the seismic signatures of discharge and bedload transport in a steep mountain channel by examining high-frequency broadband seismic data from the well-studied Erlenbach stream (local slope of ~10%) in the Swiss Prealps. The extensive monitoring infrastructure and long history of sediment transport data at this field site allow us to independently constrain discharge, precipitation, and bedload transport during flood events over a two month field campaign. We perform a general linear least squares inversion of the seismic data, exploiting times with isolated rain or discharge events, to identify the spectral signals of water turbulence, rain, and bedload sediment transport. We find that the signal generated by rain exhibits a roughly broadband spectrum, while discharge and sediment transport exhibit power primarily in lower frequency bands. Our preliminary results indicate that with only precipitation and discharge data, it is possible to isolate the seismic signal of bedload transport in steep fluvial environments. Seismic studies may therefore have the potential to revolutionize our ability to monitor and understand these environments.

  16. Wavelet transform processing applied to partial discharge evaluation

    NASA Astrophysics Data System (ADS)

    Macedo, E. C. T.; Araújo, D. B.; da Costa, E. G.; Freire, R. C. S.; Lopes, W. T. A.; Torres, I. S. M.; de Souza Neto, J. M. R.; Bhatti, S. A.; Glover, I. A.

    2012-05-01

    Partial Discharge (PD) is characterized by high frequency current pulses that occur in high voltage (HV) electrical equipments originated from gas ionization process when damaged insulation is submitted to high values of electric field [1]. PD monitoring is a useful method of assessing the aging degree of the insulation, manufacturing defects or chemical/mechanical damage. Many sources of noise (e.g. radio transmissions, commutator noise from rotating machines, power electronics switching circuits, corona discharge, etc.) can directly affect the PD estimation. Among the many mathematical techniques that can be applied to de-noise PD signals, the wavelet transform is one of the most powerful. It can simultaneously supply information about the pulse occurrence, time and pulse spectrum, and also de-noise in-field measured PD signals. In this paper is described the application of wavelet transform in the suppression of the main types of noise that can affect the observation and analysis of PD signals in high voltage apparatus. In addition, is presented a study that indicates the appropriated mother-wavelet for this application based on the cross-correlation factor.

  17. Calibration of ultra-high frequency (UHF) partial discharge sensors using FDTD method

    NASA Astrophysics Data System (ADS)

    Ishak, Asnor Mazuan; Ishak, Mohd Taufiq

    2018-02-01

    Ultra-high frequency (UHF) partial discharge sensors are widely used for conditioning monitoring and defect location in insulation system of high voltage equipment. Designing sensors for specific applications often requires an iterative process of manufacturing, testing and mechanical modifications. This paper demonstrates the use of finite-difference time-domain (FDTD) technique as a tool to predict the frequency response of UHF PD sensors. Using this approach, the design process can be simplified and parametric studies can be conducted in order to assess the influence of component dimensions and material properties on the sensor response. The modelling approach is validated using gigahertz transverse electromagnetic (GTEM) calibration system. The use of a transient excitation source is particularly suitable for modeling using FDTD, which is able to simulate the step response output voltage of the sensor from which the frequency response is obtained using the same post-processing applied to the physical measurement.

  18. Analysis of partial discharge activity by a conducting particle in liquid nitrogen under AC voltages adopting UHF technique

    NASA Astrophysics Data System (ADS)

    Sarathi, R.; Giridhar, A. V.; Sethupathi, K.

    2010-01-01

    Liquid nitrogen (LN 2) is used as an insulant as well as coolant in high temperature superconducting power equipments. Particle contamination in liquid nitrogen is one of the major cause for formation of partial discharges during operation. An attempt has been made in the present study to understand the feasibility of using Ultra High Frequency (UHF) sensors for identification of partial discharge (PD) formed due to particle movement in liquid nitrogen under AC voltages. It is observed that the partial discharge formed in LN 2 radiates UHF signal. The results of the study indicate that the conventional partial discharge measurement and UHF peak amplitude measurement have direct correlation. The Phase Resolved Partial Discharge (PRPD) analysis indicates that the partial discharge formed due to particle movement occurs in the entire phase windows of the AC voltage. The PD magnitude increases with increase in applied voltage. The frequency content of UHF signal generated due to particle movement in liquid nitrogen under AC voltages lies in the range of 0.5-1.5 GHz. The UHF sensor output signal analyzed using spectrum analyzer by operating it in zero-span mode, indicates that burst type PD occurs due to particle movement.

  19. Prerequisites for Accurate Monitoring of River Discharge Based on Fixed-Location Velocity Measurements

    NASA Astrophysics Data System (ADS)

    Kästner, K.; Hoitink, A. J. F.; Torfs, P. J. J. F.; Vermeulen, B.; Ningsih, N. S.; Pramulya, M.

    2018-02-01

    River discharge has to be monitored reliably for effective water management. As river discharge cannot be measured directly, it is usually inferred from the water level. This practice is unreliable at places where the relation between water level and flow velocity is ambiguous. In such a case, the continuous measurement of the flow velocity can improve the discharge prediction. The emergence of horizontal acoustic Doppler current profilers (HADCPs) has made it possible to continuously measure the flow velocity. However, the profiling range of HADCPs is limited, so that a single instrument can only partially cover a wide cross section. The total discharge still has to be determined with a model. While the limitations of rating curves are well understood, there is not yet a comprehensive theory to assess the accuracy of discharge predicted from velocity measurements. Such a theory is necessary to discriminate which factors influence the measurements, and to improve instrument deployment as well as discharge prediction. This paper presents a generic method to assess the uncertainty of discharge predicted from range-limited velocity profiles. The theory shows that a major source of error is the variation of the ratio between the local and cross-section-averaged velocity. This variation is large near the banks, where HADCPs are usually deployed and can limit the advantage gained from the velocity measurement. We apply our theory at two gauging stations situated in the Kapuas River, Indonesia. We find that at one of the two stations the index velocity does not outperform a simple rating curve.

  20. Improving detection sensitivity for partial discharge monitoring of high voltage equipment

    NASA Astrophysics Data System (ADS)

    Hao, L.; Lewin, P. L.; Swingler, S. G.

    2008-05-01

    Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by the authors has shown that an electro-optic system can be used for PD measurement of oil-filled power transformers. A PD signal generated within an oil-filled power transformer may reach a winding and then travel along the winding to the bushing core bar. The bushing, acting like a capacitor, can transfer the high frequency components of the partial discharge signal to its earthed tap point. Therefore, an effective PD current measurement can be implemented at the bushing tap by using a radio frequency current transducer around the bushing-tap earth connection. In addition, the use of an optical transmission technique not only improves the electrical noise immunity and provides the possibility of remote measurement but also realizes electrical isolation and enhances safety for operators. However, the bushing core bar can act as an aerial and in addition noise induced by the electro-optic modulation system may influence overall measurement sensitivity. This paper reports on a machine learning technique, namely the use of a support vector machine (SVM), to improve the detection sensitivity of the system. Comparison between the signal extraction performances of a passive hardware filter and the SVM technique has been assessed. The results obtained from the laboratory-based experiment have been analysed and indicate that the SVM approach provides better performance than the passive hardware filter and it can reliably detect discharge signals with apparent charge greater than 30 pC.

  1. A first principle simulation of competitive adsorption of SF6 decomposition components on nitrogen-doped anatase TiO2 (101) surface

    NASA Astrophysics Data System (ADS)

    Dong, Xingchen; Zhang, Xiaoxing; Cui, Hao; Zhang, Jun

    2017-11-01

    Gas insulated switchgear has been widely used in modern electric systems due to its significantly excellent performances such as compact structure and low land occupation as well as the security stability. However, inside defects caused during manufacture process can lead to partial discharge which might develop into serious insulation failure. Online monitoring method on basis of gas sensors is considered a promising way of detecting partial discharge for alarm ahead of time. Research has found that TiO2 nanotubes sensors show good response to SO2, SOF2, SO2F2, the decomposition components as a result of partial discharge. In order to investigate the gas-sensing mechanism of nitrogen-doped TiO2 prepared via plasma treatment methods to SO2, SOF2, and SO2F2, the adsorption structures of both three gas molecules and anatase TiO2 (101) surface were built, and DFT calculations were then carried out for calculation and analysis of adsorption parameters. Adsorption property comparison of anatase TiO2 (101) surface after nitrogen doping with Au doping and without doping shows that nitrogen doping can obviously enhance the adsorption energy for SO2 and SOF2 adsorption and no charge transfer for SO2F2 adsorption, further explaining the adsorption mechanism and doping influence of different doping elements.

  2. Two examples of intelligent systems based on smart materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unsworth, J.

    1994-12-31

    Two intelligent systems are described which are based on smart materials. The operation of the systems also rely on conventional well known technologies such as electronics, signal conditioning, signal processing, microprocessors and engineering design. However without the smart materials the development and integration into the intelligent systems would not have been possible. System 1 is a partial discharge monitor for on-line continuous checking of the condition of electrical power transformers. The ultrasonic and radio frequency detectors in this system rely on special piezoelectric composite integrated with a compact annular metal ring. Partial discharges set up ultrasonic and radio frequency signalsmore » which are received by the integrated detectors. The signals are amplified, conditioned, signal processed, the time interval between the two signals measured and the level of partial discharge activity averaged and assessed for numerous pairs and alarms triggered on remote control panels if the level is dangerous. The system has the capability of initiating automatic shutdown of the transformer once it is linked into the control computers of the electrical power authority. System 2 is called a Security Cradle and is an intelligent 3D shield designed to use the properties of electro active polymers to prevent hardware hackers from stealing valuable of sensitive information from memory devices (e.g., EPROMS) housed in computer or microprocessor installations.« less

  3. Design of a fast computer-based partial discharge diagnostic system

    NASA Technical Reports Server (NTRS)

    Oliva, Jose R.; Karady, G. G.; Domitz, Stan

    1991-01-01

    Partial discharges cause progressive deterioration of insulating materials working in high voltage conditions and may lead ultimately to insulator failure. Experimental findings indicate that deterioration increases with the number of discharges and is consequently proportional to the magnitude and frequency of the applied voltage. In order to obtain a better understanding of the mechanisms of deterioration produced by partial discharges, instrumentation capable of individual pulse resolution is required. A new computer-based partial discharge detection system was designed and constructed to conduct long duration tests on sample capacitors. This system is capable of recording large number of pulses without dead time and producing valuable information related to amplitude, polarity, and charge content of the discharges. The operation of the system is automatic and no human supervision is required during the testing stage. Ceramic capacitors were tested at high voltage in long duration tests. The obtained results indicated that the charge content of partial discharges shift towards high levels of charge as the level of deterioration in the capacitor increases.

  4. Water resources data, Kansas, water year 2004

    USGS Publications Warehouse

    Putnam, J.E.; Schneider, D.R.

    2005-01-01

    Water-resources data for the 2004 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 155 complete-record gaging stations; elevation and contents at 17 lakes and reservoirs; water-quality records at 2 precipitation stations, water-level data at 14 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 16 gaging stations and 2 lakes with water-quality monitors. Also included are discharge data for 29 high-flow partial-record stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.

  5. Auto-Detection of Partial Discharges in Power Cables by Descrete Wavelet Transform

    NASA Astrophysics Data System (ADS)

    Yasuda, Yoh; Hara, Takehisa; Urano, Koji; Chen, Min

    One of the serious problems that may happen in power XLPE cables is destruction of insulator. The best and conventional way to prevent such a crucial accident is generally supposed to ascertain partial corona discharges occurring at small void in organic insulator. However, there are some difficulties to detect those partial discharges because of existence of external noises in detected data, whose patterns are hardly identified at a glance. By the reason of the problem, there have been a number of researches on the way of development to accomplish detecting partial discharges by employing neural network (NN) system, which is widely known as the system for pattern recognition. We have been developing the NN system of the auto-detection for partial discharges, which we actually input numerical data of waveform itself into and obtained appropriate performance from. In this paper, we employed Descrete Wavelet Transform (DWT) to acquire more detailed transformed data in order to put them into the NN system. Employing DWT, we became able to express the waveform data in time-frequency space, and achieved effective detectiton of partial discharges by NN system. We present here the results using DWT analysis for partial discharges and noise signals which we obtained actually. Moreover, we present results out of the NN system which were dealt with those transformed data.

  6. Persulfate injection into a gasoline source zone

    NASA Astrophysics Data System (ADS)

    Sra, Kanwartej S.; Thomson, Neil R.; Barker, Jim F.

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O82 -, SO42 -, Na+, dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for > 10 months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in M indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M increased by > 100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone.

  7. Motivational stage of change in young patients undergoing day treatment for eating disorders.

    PubMed

    Bustin, Lisa A; Lane-Loney, Susan E; Hollenbeak, Christopher S; Ornstein, Rollyn M

    2013-01-01

    The objective was to determine whether motivation to change is significantly altered over the course of partial hospitalization in children and adolescents with eating disorders (EDs). This study was a retrospective chart review of 30 sets of adolescents and their parents who completed the Motivational Stage of Change for Adolescents Recovering from an Eating Disorder (MSCARED) at both intake and discharge from partial hospitalization. The main outcome variables included change in stage of change (SOC) for patients and their parents. Secondary outcomes included correlations between SOC and other baseline variables, as well as changes in SOC and psychological test scores. The SOC was significantly higher at discharge than at intake in both the patients and parents, but the two groups were not in agreement at discharge. The change in the SOC was correlated with change in Children's Eating Attitudes Test scores. Assessment of decisional balance showed correlations with SOC. Age, change in weight, and psychiatric diagnoses did not correlate with initial SOC. The MSCARED may be a useful tool for monitoring young ED patients' psychological improvements with day treatment. Initial SOC is not predictive of treatment outcomes.

  8. Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers

    PubMed Central

    Ren, Ming; Song, Bo; Dong, Ming

    2017-01-01

    Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring. PMID:29125544

  9. Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers.

    PubMed

    Ren, Ming; Zhou, Jierui; Song, Bo; Zhang, Chongxing; Dong, Ming; Albarracín, Ricardo

    2017-11-10

    Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring.

  10. Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in High-Voltage Equipment

    NASA Astrophysics Data System (ADS)

    Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.

    2018-03-01

    Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.

  11. Partial discharge testing of bulk transformer oil

    NASA Astrophysics Data System (ADS)

    Rohwein, G. J.

    The generation of partial discharges in bulk transformer oil was investigated experimentally to determine the dominant conditions which contribute to their formation and growth under repetitive impulse stresses. The motivation for conducting these experiments arose from a problem with partial discharges and breakdowns occurring in the insulating oil around the high voltage switch in a continuous running 1.5 MV repetitive pulser system. From the experiment it was found tht repetitive stressing caused low level field ionization around the electrodes which led to bubble formation and eventually partial discharges. There were also qualitative indications of charge accumulation in the oil. Photographic records of numerous shot sequences were used to study the phenomena.

  12. Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors.

    PubMed

    Zhang, Chongxing; Dong, Ming; Ren, Ming; Huang, Wenguang; Zhou, Jierui; Gao, Xuze; Albarracín, Ricardo

    2018-02-11

    Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of metal-enclosed switchgear. The transient earth voltage method, an effective non-intrusive method, has substantial engineering application value for estimating the insulation condition of switchgear. However, the practical application effectiveness of TEV detection is not satisfactory because of the lack of a TEV detection application method, i.e., a method with sufficient technical cognition and analysis. This paper proposes an innovative online PD detection system and a corresponding application strategy based on an intelligent feedback distributed TEV wireless sensor network, consisting of sensing, communication, and diagnosis layers. In the proposed system, the TEV signal or status data are wirelessly transmitted to the terminal following low-energy signal preprocessing and acquisition by TEV sensors. Then, a central server analyzes the correlation of the uploaded data and gives a fault warning level according to the quantity, trend, parallel analysis, and phase resolved partial discharge pattern recognition. In this way, a TEV detection system and strategy with distributed acquisition, unitized fault warning, and centralized diagnosis is realized. The proposed system has positive significance for reducing the fault rate of medium voltage switchgear and improving its operation and maintenance level.

  13. Integrated environmental monitoring and multivariate data analysis-A case study.

    PubMed

    Eide, Ingvar; Westad, Frank; Nilssen, Ingunn; de Freitas, Felipe Sales; Dos Santos, Natalia Gomes; Dos Santos, Francisco; Cabral, Marcelo Montenegro; Bicego, Marcia Caruso; Figueira, Rubens; Johnsen, Ståle

    2017-03-01

    The present article describes integration of environmental monitoring and discharge data and interpretation using multivariate statistics, principal component analysis (PCA), and partial least squares (PLS) regression. The monitoring was carried out at the Peregrino oil field off the coast of Brazil. One sensor platform and 3 sediment traps were placed on the seabed. The sensors measured current speed and direction, turbidity, temperature, and conductivity. The sediment trap samples were used to determine suspended particulate matter that was characterized with respect to a number of chemical parameters (26 alkanes, 16 PAHs, N, C, calcium carbonate, and Ba). Data on discharges of drill cuttings and water-based drilling fluid were provided on a daily basis. The monitoring was carried out during 7 campaigns from June 2010 to October 2012, each lasting 2 to 3 months due to the capacity of the sediment traps. The data from the campaigns were preprocessed, combined, and interpreted using multivariate statistics. No systematic difference could be observed between campaigns or traps despite the fact that the first campaign was carried out before drilling, and 1 of 3 sediment traps was located in an area not expected to be influenced by the discharges. There was a strong covariation between suspended particulate matter and total N and organic C suggesting that the majority of the sediment samples had a natural and biogenic origin. Furthermore, the multivariate regression showed no correlation between discharges of drill cuttings and sediment trap or turbidity data taking current speed and direction into consideration. Because of this lack of correlation with discharges from the drilling location, a more detailed evaluation of chemical indicators providing information about origin was carried out in addition to numerical modeling of dispersion and deposition. The chemical indicators and the modeling of dispersion and deposition support the conclusions from the multivariate statistics. Integr Environ Assess Manag 2017;13:387-395. © 2016 SETAC. © 2016 SETAC.

  14. Parts, Materials, and Processes Control Program for Expendable Launch Vehicles

    DTIC Science & Technology

    2015-07-31

    burn-in, electrical tests (DWV, room and hot IR, partial discharge when in corona region); perform DPA with SEM/EDX analysis of dielectric...life test; x-ray and vicinal illumination inspection; electrical tests (DWV, room and hot IR, partial discharge when in corona region) Termination...defects; proper voltage derating. Partial discharge testing, corona inception testing up to 60% of rated voltage; CSAM screening; voltage burn

  15. Persulfate injection into a gasoline source zone.

    PubMed

    Sra, Kanwartej S; Thomson, Neil R; Barker, Jim F

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O8(2-), SO4(2-), Na(+), dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for >10months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in [Formula: see text] indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M˙DIC increased by >100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Study of comparison between Ultra-high Frequency (UHF) method and ultrasonic method on PD detection for GIS

    NASA Astrophysics Data System (ADS)

    Li, Yanran; Chen, Duo; Li, Li; Zhang, Jiwei; Li, Guang; Liu, Hongxia

    2017-11-01

    GIS (gas insulated switchgear), is an important equipment in power system. Partial discharge plays an important role in detecting the insulation performance of GIS. UHF method and ultrasonic method frequently used in partial discharge (PD) detection for GIS. However, few studies have been conducted on comparison of this two methods. From the view point of safety, it is necessary to investigate UHF method and ultrasonic method for partial discharge in GIS. This paper presents study aimed at clarifying the effect of UHF method and ultrasonic method for partial discharge caused by free metal particles in GIS. Partial discharge tests were performed in laboratory simulated environment. Obtained results show the ability of anti-interference of signal detection and the accuracy of fault localization for UHF method and ultrasonic method. A new method based on UHF method and ultrasonic method of PD detection for GIS is proposed in order to greatly enhance the ability of anti-interference of signal detection and the accuracy of detection localization.

  17. Parts, Materials, and Processes Control Program for Expendable Launch Vehicles

    DTIC Science & Technology

    2015-05-21

    CSAM, thermal shock, voltage burn-in, electrical tests (DWV, room and hot IR, partial discharge when in corona region); perform DPA with SEM/EDX...controls to eliminate dielectric defects; proper voltage derating. Partial discharge testing, corona inception testing up to 60% of rated voltage...voltage burn-in; DWV; room and hot IR; life test; partial discharge when in corona region B-7 Table B-5. Metallized Plastic Capacitors

  18. Water Resources Data--Kansas, Water Year 2003

    USGS Publications Warehouse

    Putnam, J.E.; Schneider, D.R.

    2004-01-01

    Water-resources data for the 2003 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 148 complete-record gaging stations; elevation and contents at 17 lakes and reservoirs; water-quality records at 2 precipitation stations, water-level data at 12 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 11 gaging stations and 2 lakes with water-quality monitors. Also included are discharge data for 27 high-flow partial-record stations, miscellaneous onsite water-quality data collected at 138 stations, and suspended-sediment concentration for 11 stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.

  19. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    PubMed Central

    Zhang, Tongzhi; Pang, Fufei; Liu, Huanhuan; Cheng, Jiajing; Lv, Longbao; Zhang, Xiaobei; Chen, Na; Wang, Tingyun

    2016-01-01

    We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad/(m⋅Pa). A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work. PMID:27916900

  20. Partial and no recovery from delirium after hospital discharge predict increased adverse events.

    PubMed

    Cole, Martin G; McCusker, Jane; Bailey, Robert; Bonnycastle, Michael; Fung, Shek; Ciampi, Antonio; Belzile, Eric

    2017-01-08

    The implications of partial and no recovery from delirium after hospital discharge are not clear. We sought to explore whether partial and no recovery from delirium among recently discharged patients predicted increased adverse events (emergency room visits, hospitalisations, death) during the subsequent 3 months. Prospective study of recovery from delirium in older hospital inpatients. The Confusion Assessment Method was used to diagnose delirium in hospital and determine recovery status after discharge (T0). Adverse events were determined during the 3 months T0. Survival analysis to the first adverse event and counting process modelling for one or more adverse events were used to examine associations between recovery status (ordinal variable, 0, 1 or 2 for full, partial or no recovery, respectively) and adverse events. Of 278 hospital inpatients with delirium, 172 were discharged before the assessment of recovery status (T0). Delirium recovery status at T0 was determined for 152: 25 had full recovery, 32 had partial recovery and 95 had no recovery. Forty-four patients had at least one adverse event during the subsequent 3 months. In multivariable analysis of one or more adverse events, poorer recovery status predicted increased adverse events; the hazard ratio (HR) (95% confidence interval, CI) was 1.72 (1.09, 2.71). The association of recovery status with adverse events was stronger among patients without dementia. Partial and no recovery from delirium after hospital discharge appear to predict increased adverse events during the subsequent 3 months These findings have potentially important implications for in-hospital and post-discharge management and policy.

  1. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  2. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  3. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  4. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  5. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  6. Determining insulation condition of 110kV instrument transformers. Linking PD measurement results from both gas chromatography and electrical method

    NASA Astrophysics Data System (ADS)

    Dan, C.; Morar, R.

    2017-05-01

    Working methods for on site testing of insulations: Gas chromatography (using the TFGA-P200 chromatographer); Electrical measurements of partial discharge levels using the digital detection, recording, analysis and partial discharge acquisition system, MPD600. First performed, between 2000-2015, were the chromatographic analyses concerning electrical insulating environments of: 102 current transformers, 110kV. Items in operation, functioning in 110/20kV substations. 38 voltage transformers, 110kV also in operation, functioning in 110/20kV substations. Then, electrical measurements of partial discharge inside instrument transformers, on site (power substations) were made (starting in the year 2009, over a 7-year period, collecting data until the year 2015) according to the provisions of standard EN 61869-1:2007 „Instrument transformers. General requirements”, applying, assimilated to it, type A partial discharge test procedure, using as test voltage the very rated 110kV distribution grid voltage. Given the results of two parallel measurements, containing: to this type of failure specific gas amount (H 2) and the quantitative partial discharge’ level, establishing a clear dependence between the quantity of partial discharges and the type and amount of in oil dissolved gases inside equipments affected by this type of defect: partial discharges, was expected. Of the „population” of instrument transformers subject of the two parallel measurements, the dependency between Q IEC (apparent charge) and (H 2) (hydrogen, gas amount dissolved within their insulating environment) represents a finite assemblage situated between the two limits developed on an empirical basis.

  7. Characterization and comprehension of corona partial discharge in air under power frequency to very low frequency voltage

    NASA Astrophysics Data System (ADS)

    Yuanxiang, ZHOU; Zhongliu, ZHOU; Ling, ZHANG; Yunxiao, ZHANG; Yajun, MO; Jiantao, SUN

    2018-05-01

    For the partial discharge test of electrical equipment with large capacitance, the use of low-frequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply. However, the validity of PD test under low frequency voltage needs to be evaluated. In order to investigate the influence of voltage frequency on corona discharge in the air, the discharge test of the tip-plate electrode under the frequency from 50 to 0.1 Hz is carried out based on the impulse current method. The results show that some of the main features of corona under low frequency do not change. The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle. The magnitude of discharge and interval in positive cycle are random, while that in negative cycle are regular. With the decrease of frequency, the inception voltage increases. The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated, with discussion and interpretation from the aspects of space charge transportation, effective discharge time and transition of discharge modes. There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency. The experimental results can be the reference for mode identification of partial discharge under low frequency tests. The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency (usually 50 Hz). Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.

  8. Inductive sensor performance in partial discharges and noise separation by means of spectral power ratios.

    PubMed

    Ardila-Rey, Jorge Alfredo; Rojas-Moreno, Mónica Victoria; Martínez-Tarifa, Juan Manuel; Robles, Guillermo

    2014-02-19

    Partial discharge (PD) detection is a standardized technique to qualify electrical insulation in machines and power cables. Several techniques that analyze the waveform of the pulses have been proposed to discriminate noise from PD activity. Among them, spectral power ratio representation shows great flexibility in the separation of the sources of PD. Mapping spectral power ratios in two-dimensional plots leads to clusters of points which group pulses with similar characteristics. The position in the map depends on the nature of the partial discharge, the setup and the frequency response of the sensors. If these clusters are clearly separated, the subsequent task of identifying the source of the discharge is straightforward so the distance between clusters can be a figure of merit to suggest the best option for PD recognition. In this paper, two inductive sensors with different frequency responses to pulsed signals, a high frequency current transformer and an inductive loop sensor, are analyzed to test their performance in detecting and separating the sources of partial discharges.

  9. Forecasting of high voltage insulation performance: Testing of recommended potting materials and of capacitors

    NASA Technical Reports Server (NTRS)

    Bever, R. S.

    1984-01-01

    Nondestructive high voltage test techniques (mostly electrical methods) are studied to prevent total or catastrophic breakdown of insulation systems under applied high voltage in space. Emphasis is on the phenomenon of partial breakdown or partial discharge (P.D.) as a symptom of insulation quality, notably partial discharge testing under D.C. applied voltage. Many of the electronic parts and high voltage instruments in space experience D.C. applied stress in service, and application of A.C. voltage to any portion thereof would be prohibited. Suggestions include: investigation of the ramp test method for D.C. partial discharge measurements; testing of actual flight-type insulation specimen; perfect plotting resin samples with controlled defects for test; several types of plotting resins and recommendations of the better ones from the electrical characteristics; thermal and elastic properties are also considered; testing of commercial capaciters; and approximate acceptance/rejection/rerating criteria for sample test elements for space use, based on D.C. partial discharge.

  10. Partial discharge characteristics of polymer nanocomposite materials in electrical insulation: a review of sample preparation techniques, analysis methods, potential applications, and future trends.

    PubMed

    Izzati, Wan Akmal; Arief, Yanuar Z; Adzis, Zuraimy; Shafanizam, Mohd

    2014-01-01

    Polymer nanocomposites have recently been attracting attention among researchers in electrical insulating applications from energy storage to power delivery. However, partial discharge has always been a predecessor to major faults and problems in this field. In addition, there is a lot more to explore, as neither the partial discharge characteristic in nanocomposites nor their electrical properties are clearly understood. By adding a small amount of weight percentage (wt%) of nanofillers, the physical, mechanical, and electrical properties of polymers can be greatly enhanced. For instance, nanofillers in nanocomposites such as silica (SiO2), alumina (Al2O3) and titania (TiO2) play a big role in providing a good approach to increasing the dielectric breakdown strength and partial discharge resistance of nanocomposites. Such polymer nanocomposites will be reviewed thoroughly in this paper, with the different experimental and analytical techniques used in previous studies. This paper also provides an academic review about partial discharge in polymer nanocomposites used as electrical insulating material from previous research, covering aspects of preparation, characteristics of the nanocomposite based on experimental works, application in power systems, methods and techniques of experiment and analysis, and future trends.

  11. Thyroid gland removal - discharge

    MedlinePlus

    ... tingling in your face or lips Alternative Names Total thyroidectomy - discharge; Partial thyroidectomy - discharge; Thyroidectomy - discharge; Subtotal thyroidectomy - discharge References Lai SY, Mandel SJ, Weber RS. Management of thyroid neoplasms. In: Flint PW, Haughey BH, ...

  12. Accelerated aging test results for aerospace wire insulation constructions

    NASA Technical Reports Server (NTRS)

    Dunbar, William G.

    1995-01-01

    Several wire insulation constructions were evaluated with and without continuous glow discharges at low pressure and high temperature to determine the aging characteristics of acceptable wire insulation constructions. It was known at the beginning of the test program that insulation aging takes several years when operated at normal ambient temperature and pressure of 20 C and 760 torr. Likewise, it was known that the accelerated aging process decreases insulation life by approximately 50% for each 10 C temperature rise. Therefore, the first phases of the program, not reported in these test results, were to select wire insulation constructions that could operate at high temperature and low pressure for over 10,000 hours with negligible shrinkage and little materials' deterioration.The final phase of the program was to determine accelerated aging characteristics. When an insulation construction is subjected to partial discharges the insulation is locally heated by the bombardment of the discharges, the insulation is also subjected to ozone and other deteriorating gas particles that may significantly increase the aging process. Several insulation systems using either a single material or combinations of teflon, kapton, and glass insulation constructions were tested. All constructions were rated to be partial discharge and/or corona-free at 240 volts, 400 Hz and 260 C (500 F) for 50, 000 hours at altitudes equivalent to the Paschen law. Minimum partial discharge aging tests were preceded by screening tests lasting 20 hours at 260 C. The aging process was accelerated by subjecting the test articles to temperatures up to 370 C (700 F) with and without partial discharges. After one month operation with continuous glow discharges surrounding the test articles, most insulation systems were either destroyed or became brittle, cracked, and unsafe for use. Time with space radiation as with partial discharges is accumulative.

  13. Accelerated aging test results for aerospace wire insulation constructions

    NASA Astrophysics Data System (ADS)

    Dunbar, William G.

    1995-11-01

    Several wire insulation constructions were evaluated with and without continuous glow discharges at low pressure and high temperature to determine the aging characteristics of acceptable wire insulation constructions. It was known at the beginning of the test program that insulation aging takes several years when operated at normal ambient temperature and pressure of 20 C and 760 torr. Likewise, it was known that the accelerated aging process decreases insulation life by approximately 50% for each 10 C temperature rise. Therefore, the first phases of the program, not reported in these test results, were to select wire insulation constructions that could operate at high temperature and low pressure for over 10,000 hours with negligible shrinkage and little materials' deterioration.The final phase of the program was to determine accelerated aging characteristics. When an insulation construction is subjected to partial discharges the insulation is locally heated by the bombardment of the discharges, the insulation is also subjected to ozone and other deteriorating gas particles that may significantly increase the aging process. Several insulation systems using either a single material or combinations of teflon, kapton, and glass insulation constructions were tested. All constructions were rated to be partial discharge and/or corona-free at 240 volts, 400 Hz and 260 C (500 F) for 50, 000 hours at altitudes equivalent to the Paschen law. Minimum partial discharge aging tests were preceded by screening tests lasting 20 hours at 260 C. The aging process was accelerated by subjecting the test articles to temperatures up to 370 C (700 F) with and without partial discharges. After one month operation with continuous glow discharges surrounding the test articles, most insulation systems were either destroyed or became brittle, cracked, and unsafe for use. Time with space radiation as with partial discharges is accumulative.

  14. Rainfall, Discharge, and Water-Quality Data During Stormwater Monitoring, July 1, 2007, to June 30, 2008; Halawa Stream Drainage Basin and the H-1 Storm Drain, Oahu, Hawaii

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.; Young, Stacie T.M.

    2008-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at four stations, and water-quality data at six stations, which include the four continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2007, and June 30, 2008. A total of 16 environmental samples were collected over two storms during July 1, 2007, to June 30, 2008, within the Halawa Stream drainage area. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some samples were analyzed for only a partial list of these analytes because an insufficient volume of sample was collected by the automatic samplers. Three additional quality-assurance/quality-control samples were collected concurrently with the storm samples. A total of 16 environmental samples were collected over four storms during July 1, 2007, to June 30, 2008 at the H-1 Storm Drain. All samples at this site were collected using an automatic sampler. Samples generally were analyzed for total suspended solids, nutrients, chemical oxygen demand, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc), although some samples were analyzed for only a partial list of these analytes. During the storm of January 29, 2008, 10 discrete samples were collected. Varying constituent concentrations were detected for the samples collected at different times during this storm event. Two quality-assurance/quality-control samples were collected concurrently with the storm samples. Three additional quality-assurance/quality-control samples were collected during routine sampler maintenance to check the effectiveness of equipment-cleaning procedures.

  15. Inductive Sensor Performance in Partial Discharges and Noise Separation by Means of Spectral Power Ratios

    PubMed Central

    Ardila-Rey, Jorge Alfredo; Rojas-Moreno, Mónica Victoria; Martínez-Tarifa, Juan Manuel; Robles, Guillermo

    2014-01-01

    Partial discharge (PD) detection is a standardized technique to qualify electrical insulation in machines and power cables. Several techniques that analyze the waveform of the pulses have been proposed to discriminate noise from PD activity. Among them, spectral power ratio representation shows great flexibility in the separation of the sources of PD. Mapping spectral power ratios in two-dimensional plots leads to clusters of points which group pulses with similar characteristics. The position in the map depends on the nature of the partial discharge, the setup and the frequency response of the sensors. If these clusters are clearly separated, the subsequent task of identifying the source of the discharge is straightforward so the distance between clusters can be a figure of merit to suggest the best option for PD recognition. In this paper, two inductive sensors with different frequency responses to pulsed signals, a high frequency current transformer and an inductive loop sensor, are analyzed to test their performance in detecting and separating the sources of partial discharges. PMID:24556674

  16. Extending helium partial pressure measurement technology to JET DTE2 and ITER.

    PubMed

    Klepper, C C; Biewer, T M; Kruezi, U; Vartanian, S; Douai, D; Hillis, D L; Marcus, C

    2016-11-01

    The detection limit for helium (He) partial pressure monitoring via the Penning discharge optical emission diagnostic, mainly used for tokamak divertor effluent gas analysis, is shown here to be possible for He concentrations down to 0.1% in predominantly deuterium effluents. This result from a dedicated laboratory study means that the technique can now be extended to intrinsically (non-injected) He produced as fusion reaction ash in deuterium-tritium experiments. The paper also examines threshold ionization mass spectroscopy as a potential backup to the optical technique, but finds that further development is needed to attain with plasma pulse-relevant response times. Both these studies are presented in the context of continuing development of plasma pulse-resolving, residual gas analysis for the upcoming JET deuterium-tritium campaign (DTE2) and for ITER.

  17. Partial Discharge Characteristics of Polymer Nanocomposite Materials in Electrical Insulation: A Review of Sample Preparation Techniques, Analysis Methods, Potential Applications, and Future Trends

    PubMed Central

    Izzati, Wan Akmal; Adzis, Zuraimy; Shafanizam, Mohd

    2014-01-01

    Polymer nanocomposites have recently been attracting attention among researchers in electrical insulating applications from energy storage to power delivery. However, partial discharge has always been a predecessor to major faults and problems in this field. In addition, there is a lot more to explore, as neither the partial discharge characteristic in nanocomposites nor their electrical properties are clearly understood. By adding a small amount of weight percentage (wt%) of nanofillers, the physical, mechanical, and electrical properties of polymers can be greatly enhanced. For instance, nanofillers in nanocomposites such as silica (SiO2), alumina (Al2O3) and titania (TiO2) play a big role in providing a good approach to increasing the dielectric breakdown strength and partial discharge resistance of nanocomposites. Such polymer nanocomposites will be reviewed thoroughly in this paper, with the different experimental and analytical techniques used in previous studies. This paper also provides an academic review about partial discharge in polymer nanocomposites used as electrical insulating material from previous research, covering aspects of preparation, characteristics of the nanocomposite based on experimental works, application in power systems, methods and techniques of experiment and analysis, and future trends. PMID:24558326

  18. Results of Boron, Surfactant, and Cyanide Investigation, Beale AFB, California

    DTIC Science & Technology

    1991-07-01

    ensure that their discharge does not produce instream toxicity. The Discharger shall carry-out the biotoxicity monitoring program in accordance with...Discharger shall implement the approved biotoxicity monitoring program. d. The Discharger shall submit the results of the biotoxicity monitoring program to

  19. Study of New Method Combined Ultra-High Frequency (UHF) Method and Ultrasonic Method on PD Detection for GIS

    NASA Astrophysics Data System (ADS)

    Li, Yanran; Chen, Duo; Zhang, Jiwei; Chen, Ning; Li, Xiaoqi; Gong, Xiaojing

    2017-09-01

    GIS (gas insulated switchgear), is an important equipment in power system. Partial discharge plays an important role in detecting the insulation performance of GIS. UHF method and ultrasonic method frequently used in partial discharge (PD) detection for GIS. It is necessary to investigate UHF method and ultrasonic method for partial discharge in GIS. However, very few studies have been conducted on the method combined this two methods. From the view point of safety, a new method based on UHF method and ultrasonic method of PD detection for GIS is proposed in order to greatly enhance the ability of anti-interference of signal detection and the accuracy of fault localization. This paper presents study aimed at clarifying the effect of the new method combined UHF method and ultrasonic method. Partial discharge tests were performed in laboratory simulated environment. Obtained results show the ability of anti-interference of signal detection and the accuracy of fault localization for this new method combined UHF method and ultrasonic method.

  20. Critical analysis of partial discharge dynamics in air filled spherical voids

    NASA Astrophysics Data System (ADS)

    Callender, G.; Golosnoy, I. O.; Rapisarda, P.; Lewin, P. L.

    2018-03-01

    In this paper partial discharge (PD) is investigated inside a spherical air filled void at atmospheric pressure using a drift diffusion model. Discharge dynamics consisted of an electron avalanche transitioning into positive streamer, in agreement with earlier work on dielectric barrier discharges. Different model configurations were utilised to test many of the concepts employed in semi-analytical PD activity models, which use simplistic descriptions of the discharge dynamics. The results showed that many of these concepts may be erroneous, with significant discrepancies between the canonical reasoning and the simulation results. For example, the residual electric field, the electric field after a discharge, is significantly lower than the estimates used by classical PD activity models in the literature.

  1. Advanced high frequency partial discharge measuring system

    NASA Technical Reports Server (NTRS)

    Karady, George G.

    1994-01-01

    This report explains the Advanced Partial Discharge Measuring System in ASU's High Voltage Laboratory and presents some of the results obtained using the setup. While in operation an insulation is subjected to wide ranging temperature and voltage stresses. Hence, it is necessary to study the effect of temperature on the behavior of partial discharges in an insulation. The setup described in this report can be used to test samples at temperatures ranging from -50 C to 200 C. The aim of conducting the tests described herein is to be able to predict the behavior of an insulation under different operating conditions in addition to being able to predict the possibility of failure.

  2. Investigation of Gas-Sensing Property of Acid-Deposited Polyaniline Thin-Film Sensors for Detecting H2S and SO2

    PubMed Central

    Dong, Xingchen; Zhang, Xiaoxing; Wu, Xiaoqing; Cui, Hao; Chen, Dachang

    2016-01-01

    Latent insulation defects introduced in manufacturing process of gas-insulated switchgears can lead to partial discharge during long-time operation, even to insulation fault if partial discharge develops further. Monitoring of decomposed components of SF6, insulating medium of gas-insulated switchgear, is a feasible method of early-warning to avoid the occurrence of sudden fault. Polyaniline thin-film with protonic acid deposited possesses wide application prospects in the gas-sensing field. Polyaniline thin-film sensors with only sulfosalicylic acid deposited and with both hydrochloric acid and sulfosalicylic acid deposited were prepared by chemical oxidative polymerization method. Gas-sensing experiment was carried out to test properties of new sensors when exposed to H2S and SO2, two decomposed products of SF6 under discharge. The gas-sensing properties of these two sensors were compared with that of a hydrochloric acid deposited sensor. Results show that the hydrochloric acid and sulfosalicylic acid deposited polyaniline thin-film sensor shows the most outstanding sensitivity and selectivity to H2S and SO2 when concentration of gases range from 10 to 100 μL/L, with sensitivity changing linearly with concentration of gases. The sensor also possesses excellent long-time and thermal stability. This research lays the foundation for preparing practical gas-sensing devices to detect H2S and SO2 in gas-insulated switchgears at room temperature. PMID:27834895

  3. Hospitalization for partial nephrectomy was not associated with intrathecal opioid analgesia: Retrospective analysis.

    PubMed

    Weingarten, Toby N; Del Mundo, Serena B; Yeoh, Tze Yeng; Scavonetto, Federica; Leibovich, Bradley C; Sprung, Juraj

    2014-10-01

    The aim of this retrospective study is to test the hypothesis that the use of spinal analgesia shortens the length of hospital stay after partial nephrectomy. We reviewed all patients undergoing partial nephrectomy for malignancy through flank incision between January 1, 2008, and June 30, 2011. We excluded patients who underwent tumor thrombectomy, used sustained-release opioids, or had general anesthesia supplemented by epidural analgesia. Patients were grouped into "spinal" (intrathecal opioid injection for postoperative analgesia) versus "general anesthetic" group, and "early" discharge group (within 3 postoperative days) versus "late" group. Association between demographics, patient physical status, anesthetic techniques, and surgical complexity and hospital stay were analyzed using multivariable logistic regression analysis. Of 380 patients, 158 (41.6%) were discharged "early" and 151 (39.7%) were "spinal" cases. Both spinal and early discharge groups had better postoperative pain control and used less postoperative systemic opioids. Spinal analgesia was associated with early hospital discharge, odds ratio 1.52, (95% confidence interval 1.00-2.30), P = 0.05, but in adjusted analysis was no longer associated with early discharge, 1.16 (0.73-1.86), P = 0.52. Early discharge was associated with calendar year, with more recent years being associated with early discharge. Spinal analgesia combined with general anesthesia was associated with improved postoperative pain control during the 1(st) postoperative day, but not with shorter hospital stay following partial nephrectomy. Therefore, unaccounted practice changes that occurred during more recent times affected hospital stay.

  4. Ultra-broadband phase-sensitive optical time-domain reflectometry with a temporally sequenced multi-frequency source.

    PubMed

    Wang, Zhaoyong; Pan, Zhengqing; Fang, Zujie; Ye, Qing; Lu, Bin; Cai, Haiwen; Qu, Ronghui

    2015-11-15

    A phase-sensitive optical time-domain reflectometry (Φ-OTDR) with a temporally sequenced multi-frequency (TSMF) source is proposed. This technique can improve the system detection bandwidth without the sensing range decreasing. Up to 0.5 MHz detection bandwidth over 9.6 km is experimentally demonstrated as an example. To the best of our knowledge, this is the first time that such a high detection bandwidth over such a long sensing range is reported in Φ-OTDR-based distributed vibration sensing. The technical issues of TSMF Φ-OTDR are discussed in this Letter. This technique will help Φ-OTDR find new important foreground in long-haul distributed broadband-detection applications, such as structural-health monitoring and partial-discharge online monitoring of high voltage power cables.

  5. Anticipating electrical breakdown in dielectric elastomer actuators

    NASA Astrophysics Data System (ADS)

    Muffoletto, Daniel P.; Burke, Kevin M.; Zirnheld, Jennifer L.

    2013-04-01

    The output strain of a dielectric elastomer actuator is directly proportional to the square of its applied electric field. However, since the likelihood of electric breakdown is elevated with an increased applied field, the maximum operating electric field of the dielectric elastomer is significantly derated in systems employing these actuators so that failure due to breakdown remains unlikely even as the material ages. In an effort to ascertain the dielectric strength so that stronger electric fields can be applied, partial discharge testing is used to assess the health of the actuator by detecting the charge that is released when localized instances of breakdown partially bridge the insulator. Pre-stretched and unstretched samples of VHB4910 tape were submerged in dielectric oil to remove external sources of partial discharges during testing, and the partial discharge patterns were recorded just before failure of the dielectric sample.

  6. Schizophrenia: Impact of psychopathology, faith healers and psycho-education on adherence to medications.

    PubMed

    Abdel Aziz, Karim; Elamin, Mohammed H; El-Saadouni, Nisrin M; El-Gabry, Dina Aly; Barakat, Mahmoud; Alhayyas, Fatima; Moselhy, Hamdy F

    2016-12-01

    Many patients suffering from psychosis are nonadherent to their medications. Nonadherence can range from treatment refusal to irregular use or partial change in daily medication doses. To investigate whether symptom dimensions, post-discharge care plans and being involved with faith healer affect the adherence to treatment in patients with schizophrenia. A total of 121 patients with schizophrenia were examined 6 weeks post-discharge from the inpatient unit and assessed for full, partial or nonadherence to medication. There was a significant association between family involvement and partial adherence and between community team involvement post-discharge and full adherence to medications. Psycho-education was a predictor for adherence to medications, persecutory delusions and lack of insight predicted partial adherence, while being involved with faith healers predicted nonadherence. Adherence to medications and socio-demographic variables are independent. This study demonstrated that nonadherence or partial adherence to medications is associated with lack of insight and persecutory delusions. Psycho-education could improve the adherence to medication compliances. © The Author(s) 2016.

  7. Partial discharge measurements on 110kV current transformers. Setting the control value. Case study

    NASA Astrophysics Data System (ADS)

    Dan, C.; Morar, R.

    2017-05-01

    The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).

  8. DC partial discharge/environmental test screening of space TWTS

    NASA Astrophysics Data System (ADS)

    Hai, F.; Paschen, K. W.

    Direct-current partial discharge/environmental tests are being conducted on traveling wave tubes (TWTs) designated for long-term space operation to screen out tubes with high voltage defects. Two types of TWTs with different external high-voltage insulation are being examined: (1) TWTs with polymeric potting, and (2) TWTs with ceramic feedthroughs. Detection of high voltage defects in the form of cracks and seprations in potted systems is enhanced by combining dc partial discharge testing with environmental (temperature and pressure) testing. These defects are usually caused by high stresses in the potting produced during temperature excursions by the difference in thermal expansion between the potting material and the confining ceramic-metal structure. Tests of all-ceramic-insulated TWTs indicate that the high voltage problem is internal to the vacuum envelope and requires both leakage and discharge measurements for diagnosis. This problem appears to be field emission from contaminated surfaces.

  9. Hospitalization for partial nephrectomy was not associated with intrathecal opioid analgesia: Retrospective analysis

    PubMed Central

    Weingarten, Toby N.; Del Mundo, Serena B.; Yeoh, Tze Yeng; Scavonetto, Federica; Leibovich, Bradley C.; Sprung, Juraj

    2014-01-01

    Background: The aim of this retrospective study is to test the hypothesis that the use of spinal analgesia shortens the length of hospital stay after partial nephrectomy. Materials and Methods: We reviewed all patients undergoing partial nephrectomy for malignancy through flank incision between January 1, 2008, and June 30, 2011. We excluded patients who underwent tumor thrombectomy, used sustained-release opioids, or had general anesthesia supplemented by epidural analgesia. Patients were grouped into “spinal” (intrathecal opioid injection for postoperative analgesia) versus “general anesthetic” group, and “early” discharge group (within 3 postoperative days) versus “late” group. Association between demographics, patient physical status, anesthetic techniques, and surgical complexity and hospital stay were analyzed using multivariable logistic regression analysis. Results: Of 380 patients, 158 (41.6%) were discharged “early” and 151 (39.7%) were “spinal” cases. Both spinal and early discharge groups had better postoperative pain control and used less postoperative systemic opioids. Spinal analgesia was associated with early hospital discharge, odds ratio 1.52, (95% confidence interval 1.00-2.30), P = 0.05, but in adjusted analysis was no longer associated with early discharge, 1.16 (0.73-1.86), P = 0.52. Early discharge was associated with calendar year, with more recent years being associated with early discharge. Conclusion: Spinal analgesia combined with general anesthesia was associated with improved postoperative pain control during the 1st postoperative day, but not with shorter hospital stay following partial nephrectomy. Therefore, unaccounted practice changes that occurred during more recent times affected hospital stay. PMID:25422611

  10. Experimental measurements concerning the stator insulation partial discharge level of a hydro-generator of high power

    NASA Astrophysics Data System (ADS)

    Haţiegan, C.; Răduca, E.; Popescu, C.; Hamat, C. O.; Băra, A.; Anghel, D.; Pîrşan, D. A.

    2018-01-01

    The paper presents a determining and evaluating method from an experimental point of view of the partial discharges level from the insulation of the stator of a synchronous hydro-generator of high power that appear at different temperatures. The temperature is measured directly on the coil with placed thermo-resistant elements between the superior and inferior bars. Also, the level of partial discharges with the coil age in a cold state, at the temperature level of the surrounding environment from within the stator, but also in a warm state at different temperatures, is measured. Through this method there is created the possibility of highlighting some eventual degradations of the coil insulation of a hydro-generator.

  11. [Clinical and electrophysiologic studies on epileptic negative myoclonus in atypical benign partial epilepsy of childhood].

    PubMed

    Yang, Zhi-xian; Liu, Xiao-yan; Qin, Jiong; Zhang, Yue-hua; Bao, Xin-hua; Chang, Xing-zhi; Wu, Ye; Xiong, Hui

    2008-12-01

    To investigate the clinical, neurophysiologic characteristics and therapeutic considerations of epileptic negative myoclonus (ENM) in atypical benign partial epilepsy of childhood (ABPE). Video-EEG monitoring with outstretched arm tests were carried out in 17 patients, and 9 of them were examined with simultaneous electromyography (EMG). The ENM manifestations, electrophysiologic features and responses to antiepileptic drugs (AED) were analyzed. Seventeen patients were diagnosed as having benign childhood epilepsy with centrotemporal spikes (BECT) during the early course of the disease and were treated with AED. During the course of the disease, hand trembling, objects dropping, head nodding and instability during standing might be clues for ENM occurrence. ENM had been confirmed in our patients by outstretched arm tests during video-EEG recording. The ictal EEG showed that high-amplitude spikes followed by a slow wave over the contralateral motor areas. This was further confirmed by time-locked silent EMG in 9 patients. During ENM occurrence or recurrence, the habitual seizures and interictal discharges were exaggerated. Atypical absence seizures also occurred in 6 patients. The alteration of therapeutic options of AED relating to ENM appearance in some patients included the add-on therapy with carbamazepine (CBZ), oxcarbazepine, phenobarbital, or withdrawal of valproate (VPA). ENM was controlled in most cases by using VPA, clonazepam (CZP) and corticosteroid with different combination. ENM could occur during the course of ABPE. Outstretching arm tests during video-EEG monitoring in combination with EMG was essential to confirm ENM. The ENM occurrence was always associated with the frequency increasing of habitual seizures and the aggravation of interictal discharges. Some AED such as CBZ might induce ENM. VPA, benzodiazepines and corticosteroid with different combination were relatively effective in treatment of ENM.

  12. A study on epileptic negative myoclonus in atypical benign partial epilepsy of childhood.

    PubMed

    Yang, Zhixian; Liu, Xiaoyan; Qin, Jiong; Zhang, Yuehua; Bao, Xinhua; Chang, Xingzhi; Wang, Shuang; Wu, Ye; Xiong, Hui

    2009-04-01

    To investigate the clinical and neurophysiological characteristics, particularly therapeutic considerations, of epileptic negative myoclonus (ENM) in atypical benign partial epilepsy (ABPE) of childhood. From 1998 to 2006, 14/242 patients with benign children epilepsy with centrotemporal spikes (BECTS) were diagnosed as having ABPE with ENM. In all 14 patients, we performed video-EEG monitoring along with tests with the patient's arms outstretched; 6/14 patients were also simultaneously underwent surface electromyogram (EMG). ENM manifestations, electrophysiological features, and responses to antiepileptic drugs were analyzed. In all cases, ENM developed after the onset of epilepsy and during antiepileptic drug therapy, and the appearance of ENM were corresponding to EEG findings of high-amplitude spikes followed by a slow wave in the contralateral motor areas with secondary generalization. This was further confirmed by time-locked silent EMG. During ENM occurrence or recurrence, habitual seizures and interictal discharges were exaggerated. In some patients, the changes in antiepileptic drug regimens in relation to ENM appearance included add-on therapy with carbamazepine, oxcarbazepine, and phenobarbital or withdrawal of valproate. ENM was controlled in most cases by administration of various combinations of valproate, clonazepam, and corticosteroids. The incidence of ENM or ABPE in our center was approximately 5.79%. A combination of video-EEG monitoring with the patient's arms outstretched and EMG is essential to identify ENM. The aggravation of habitual seizures and interictal discharges indicate ENM. Some antiepileptic drugs, such as carbamazepine, oxcarbazepine, and phenobarbital, may be related to ENM occurrence during spontaneous aggravation of ABPE. Various combinations of valproate, benzodiazepines, and corticosteroids are relatively effective for treating ENM that occurs in ABPE.

  13. Non-contact flow gauging for the extension and development of rating curves

    NASA Astrophysics Data System (ADS)

    Perks, Matthew; Large, Andy; Russell, Andy

    2015-04-01

    Accurate measurement of river discharge is fundamental to understanding hydrological processes, associated hazards and ecological responses within fluvial systems. Established protocols for determining river discharge are partial, predominantly invasive and logistically difficult during high flows. There is demand for new methods for accurate quantification of flow velocity under high-flow/flood conditions to in turn enable better post-event reconstruction of peak discharge. As a consequence considerable effort has been devoted to the development of innovative technologies for the representation of flow in open channels. Remotely operated fixed and mobile systems capable of providing quantitative estimates of instantaneous and time-averaged flow characteristics using non-contact methods has been a major development. Amongst the new approaches for stand-alone continuous monitoring of surface flows is Large Scale Particle Image Velocimetry (LSPIV). Here we adapt the LSPIV concept, to provide continuous discharge measurements in non-uniform channels with complex flow conditions. High Definition videos (1080p; 30fps) of the water surface are acquired at 5 minute intervals. The image is rectified to correct for perspective distortion using a new, open source tool which minimises errors resulting from oblique image capture. Naturally occurring artefacts on the water surface (e.g. bubbles, debris, etc.) are tracked with the Kanade-Lucas-Tomasi (KLT) algorithm. The data generated is in the form of a complex surface water velocity field which can be interrogated to extract a range of hydrological information such as the streamwise velocity at a cross-section of interest, or even allow the interrogation of hydrodynamic flow structures. Here we demonstrate that this approach is capable of generating river discharge data comparable to concurrent measurements made using existing, accepted technologies (e.g. ADCP). The outcome is better constraint and extension of rating curves. The approach is suited to water management authorities throughout Europe who seek ever-increasingly cost-effective and non-invasive techniques for maximising the monitoring capabilities of their operational network.

  14. Using "residual depths" to monitor pool depths independently of discharge

    Treesearch

    Thomas E. Lisle

    1987-01-01

    As vital components of habitat for stream fishes, pools are often monitored to follow the effects of enhancement projects and natural stream processes. Variations of water depth with discharge, however, can complicate monitoring changes in the depth and volume of pools. To subtract the effect of discharge on depth in pools, residual depths can be measured. Residual...

  15. 40 CFR 468.03 - Monitoring and reporting requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard. ...

  16. 40 CFR 468.03 - Monitoring and reporting requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard. ...

  17. 40 CFR 468.03 - Monitoring and reporting requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard. ...

  18. 40 CFR 468.03 - Monitoring and reporting requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard. ...

  19. Appropriate VTE prophylaxis is associated with lower direct medical costs.

    PubMed

    Amin, Alpesh; Hussein, Mohamed; Battleman, David; Lin, Jay; Stemkowski, Stephen; Merli, Geno J

    2010-11-01

    To calculate and compare the direct medical costs of guideline-recommended prophylaxis with prophylaxis that does not fully adhere with guideline recommendations in a large, real-world population. Discharge records were retrieved from the US Premier Perspective™ database (January 2003-December 2003) for patients aged≥40 years with a primary diagnosis of cancer, chronic heart failure, lung disease, or severe infectious disease who received some form of thromboprophylaxis. Univariate analysis and multivariate regression modeling were performed to compare direct medical costs between discharges who received appropriate prophylaxis (correct type, dose, and duration based on sixth edition American College of Chest Physicians [ACCP] recommendations) and partial prophylaxis (not in full accordance with ACCP recommendations). Market segmentation analysis was used to compare costs stratified by hospital and patient characteristics. Of the 683 005 discharges included, 148,171 (21.7%) received appropriate prophylaxis and 534,834 (78.3%) received partial prophylaxis. The total direct unadjusted costs were $15,439 in the appropriate prophylaxis group and $17,763 in the partial prophylaxis group. After adjustment, mean adjusted total costs per discharge were lower for those receiving appropriate prophylaxis ($11,713; 95% confidence interval [CI], $11,675-$11,753) compared with partial prophylaxis ($13,369; 95% CI, $13,332-$13 406; P<0.01). Appropriate prophylaxis appeared to be associated with numerically lower unadjusted costs than partial prophylaxis, regardless of hospital size, rural/urban location, teaching status, and patient age and gender. This large, real-world analysis suggests that appropriate prophylaxis, in adherence with ACCP guidelines, is potentially cost-saving compared with partial prophylaxis in at-risk medical patients.

  20. Tonle Sap Lake Water Storage Change Over 24 Years From Satellite Observation and Its Link With Mekong River Discharge and Climate Events

    NASA Astrophysics Data System (ADS)

    Biancamaria, S.; Frappart, F.; Normandin, C.; Blarel, F.; Bourrel, L.; Aumont, M.; Azema, P.; Vu, P. L.; Lubac, B.; Darrozes, J.

    2017-12-01

    The Tonle Sap lake is the largest freshwater lake in Southeast Asia and is located within the Mekong basin (mainly in Cambodia). It is one of he most productive ecosystem of the world and provide two thirds of Cambodia fish catch. It also plays a unique role on the Mekong basin hydrological cycle: during the monsoon period, the Mekong river partially flows to the lake, whereas during the dry season, the lake flows to the Mekong delta. It is therefore crucial to monitor and take into account this lake to estimate Mekong discharge to the ocean. However, in situ measurements of lake level and river discharge are very sparse (especially during the last decades) and computing lake storage variation from in situ data only is difficult due to the huge annual variation of lake area. That's why, satellite data (nadir radar altimetry and visible imagery) have been used to study its volume variation and its relationship with climate events and Mekong river discharge. Multi-mission altimetry data have been extracted (Topex, ERS-2, ENVISAT, Jason-1, Jason-2, Saral and Jason-3, using CTOH data extraction tools) to derive a lake water level from1993 to 2016, which varies from 3 m to 12 m. Lake area have been computed from MODIS data from 2000 to 2016 and varies from 3,400 km2 to 11,800 km2. These dataset clearly shows a relationship between lake water level and area, which has been used to estimate lake water volume change from 1995 to 2016, with a minimum in 2015 and a maximum in 2011. Lake's droughts and floods can be observed during moderate and strong El Nino/La Nina events, enhanced by the Pacific Decadal Oscillation. Besides, comparison with in situ discharge at the outlet of the Mekong basin (over 1995/2000 time period) shows that lake water level is 20 days time lagged and increases/decreases after Mekong discharge at its outlet. This time lag results of Mekong river partially flowing to the lake. Finally, high correlation between lake level and outlet discharge allows to use lake water level to derive Mekong discharge at its outlet after 2000, when in situ time series are not available anymore to the international scientific community. In the future, to improve time sampling, Sentinel-2 images and data from Sentinel-3 altimeter will be used.

  1. Water Resources Data, Georgia, 2000, Volume 1: Continuous water-level, streamflow, water-quality data, and periodic water-quality data, Water Year 2000

    USGS Publications Warehouse

    McCallum, Brian E.; Hickey, Andrew C.

    2000-01-01

    Water resources data for the 2000 water year for Georgia consists of records of stage, discharge, and water quality of streams; and the stage and contents of lakes and reservoirs published in one volume in a digital format on a CD-ROM. This volume contains discharge records of 125 gaging stations; stage for 20 gaging stations; information for 18 lakes and reservoirs; continuous water-quality records for 10 stations; the annual peak stage and annual peak discharge for 77 crest-stage partial-record stations; and miscellaneous streamflow measurements at 21 stations. These data represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in Georgia. Note: Historically, this report was published as a paper report. For the 1999 and subsequent water-year reports, the Water Resources Data for Georgia changed to a new, more informative and functional format on CD-ROM. The format is based on a geographic information system (GIS) user interface that allows the user to view map locations of the hydrologic monitoring stations and networks within respective river basins.

  2. Fiberoptic nasopharyngolaryngoscopy for airway monitoring after obstructive sleep apnea surgery.

    PubMed

    Li, K K; Riley, R W; Powell, N B; Zonato, A

    2000-12-01

    This study evaluated the upper airway characteristics in the early postoperative period after reconstructive surgery for obstructive sleep apnea (OSA). During a 24-month period, the upper airway of patients who underwent uvulopalatopharyngoplasty (UPPP) with genioglossus advancement (GA) or hyoid myotomy (HM) or maxillomandibular advancement (MMA) were evaluated with fiberoptic nasopharyngolaryngoscopy (NPG) preoperatively and 24 to 72 hours postoperatively. NPG was performed on 271 patients. One hundred seventy-three patients had UPPP with GA or HM, and the remainder had MMA. All of the patients who underwent UPPP with GA or HM were found to have varying degrees of soft tissue edema involving the soft palate and the tongue base. The patients who underwent tonsillectomies and UPPP with GA or HM had greater soft palate/pharyngeal wall edema. In contrast, patients who underwent MMA had minimal edema involving the soft palate and the base of tongue, but diffuse lateral pharyngeal wall edema throughout the upper airway was identified. Eighteen of the MMA patients had ecchymosis and edema involving the pyriform sinus and aryepiglottic fold; 4 of these patients also had a hypopharyngeal hematoma involving the pyriform sinus, aryepiglottic fold, arytenoid, and false vocal cord, which partially obstructed the airway. These 4 patients were closely monitored for 1 to 2 additional days, and all were discharged without problems. None of the patients in the study had postoperative airway obstruction. NPG may be useful in postoperative airway monitoring and assist in discharge planning after upper airway reconstruction in the OSA patients.

  3. 77 FR 58830 - State Program Requirements; Application To Administer Partial National Pollutant Discharge...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-24

    ... Pollutant Discharge Elimination System (AgPDES) program pursuant to Section 402(b) of the Clean Water Act... Discharge Elimination System (NPDES) permit program under Section 402(n)(3) of the Act for all discharges of... through Friday, excluding legal holidays, at EPA Region 6, 1445 Ross Ave., Dallas, Texas 75202. A copy of...

  4. Rainfall, Streamflow, and Water-Quality Data During Stormwater Monitoring, Halawa Stream Drainage Basin, Oahu, Hawaii, July 1, 2005 to June 30, 2006

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.; Young-Smith, Stacie T. M.

    2006-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous discharge data at one station, continuous streamflow data at two stations, and water-quality data at five stations, which include the continuous discharge and streamflow stations. This report summarizes rainfall, discharge, streamflow, and water-quality data collected between July 1, 2005 and June 30, 2006. A total of 23 samples was collected over five storms during July 1, 2005 to June 30, 2006. The goal was to collect grab samples nearly simultaneously at all five stations, and flow-weighted time-composite samples at the three stations equipped with automatic samplers; however, all five storms were partially sampled owing to lack of flow at the time of sampling at some sites, or because some samples collected by the automatic sampler did not represent water from the storm. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.

  5. On the derivation of flow rating curves in data-scarce environments

    NASA Astrophysics Data System (ADS)

    Manfreda, Salvatore

    2018-07-01

    River monitoring is a critical issue for hydrological modelling that relies strongly on the use of flow rating curves (FRCs). In most cases, these functions are derived by least-squares fitting which usually leads to good performance indices, even when based on a limited range of data that especially lack high flow observations. In this context, cross-section geometry is a controlling factor which is not fully exploited in classical approaches. In fact, river discharge is obtained as the product of two factors: 1) the area of the wetted cross-section and 2) the cross-sectionally averaged velocity. Both factors can be expressed as a function of the river stage, defining a viable alternative in the derivation of FRCs. This makes it possible to exploit information about cross-section geometry limiting, at least partially, the uncertainty in the extrapolation of discharge at higher flow values. Numerical analyses and field data confirm the reliability of the proposed procedure for the derivation of FRCs.

  6. Influence of catalyst packing configuration on the discharge characteristics of dielectric barrier discharge reactors: A numerical investigation

    NASA Astrophysics Data System (ADS)

    Gadkari, Siddharth; Gu, Sai

    2018-06-01

    A two-dimensional numerical fluid model is developed for studying the influence of packing configurations on dielectric barrier discharge (DBD) characteristics. Discharge current profiles and time averaged electric field strength, electron number density, and electron temperature distributions are compared for the three DBD configurations, plain DBD with no packing, partially packed DBD, and fully packed DBD. The results show that a strong change in discharge behaviour occurs when a DBD is fully packed as compared to partial packing or no packing. While the average electric field strength and electron temperature of a fully packed DBD are higher relative to the other DBD configurations, the average electron density is substantially lower and may impede the DBD reactor performance under certain operating conditions. Possible scenarios of the synergistic effect of the combination of plasma with catalysis are also discussed.

  7. Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors

    PubMed Central

    2018-01-01

    Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when PD measurements are carried out on-site and on-line. For utilities, the most attractive characteristics of on-line measurements are that once the sensors are installed in the grid, the electrical service is uninterrupted and that electrical systems are tested in real operating conditions. In medium-voltage (MV) and HV installations, one of the critical points where an insulation defect can occur is inside metal-clad switchgears (including the cable terminals connected to them). Thus, this kind of equipment is increasingly being monitored to carry out proper maintenance based on their condition. This paper presents a study concerning the application of different electromagnetic measuring techniques (compliant with IEC 62478 and IEC 60270 standards), together with the use of suitable sensors, which enable the evaluation of the insulation condition mainly in MV switchgears. The main scope is to give a general overview about appropriate types of electromagnetic measuring methods and sensors to be applied, while considering the level of detail and accuracy in the diagnosis and the particular fail-save requirements of the electrical installations where the switchgears are located. PMID:29495601

  8. On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation

    PubMed Central

    Albarracín, Ricardo; Ardila-Rey, Jorge Alfredo; Mas’ud, Abdullahi Abubakar

    2016-01-01

    A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside. PMID:26821022

  9. On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation.

    PubMed

    Albarracín, Ricardo; Ardila-Rey, Jorge Alfredo; Mas'ud, Abdullahi Abubakar

    2016-01-25

    A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside.

  10. [Implementation of a post-discharge surgical site infection system in herniorrhaphy and mastectomy procedures].

    PubMed

    San Juan Sanz, Isabel; Díaz-Agero-Pérez, Cristina; Robustillo-Rodela, Ana; Pita López, María José; Oliva Iñiguez, Lourdes; Monge-Jodrá, Vicente

    2014-10-01

    Monitoring surgical site infection (SSI) performed during hospitalization can underestimate its rates due to the shortening in hospital stay. The aim of this study was to determine the actual rates of SSI using a post-discharge monitoring system. All patients who underwent herniorraphy or mastectomy in the Hospital Universitario Ramón y Cajal from 1 January 2011 to 31 December 2011 were included. SSI data were collected prospectively according to the continuous quality improvement indicators (Indicadores Clinicos de Mejora Continua de la Calidad [INCLIMECC]) monitoring system. Post-discharge follow-up was conducted by telephone survey. A total of 409patients were included in the study, of whom 299 underwent a herniorraphy procedure, and 110 underwent a mastectomy procedure. For herniorrhaphy, the SSI rate increased from 6.02% to 7.6% (the post-discharge survey detected 21.7% of SSI). For mastectomy, the SSI rate increased from 1.8% to 3.6% (the post-discharge survey detected 50% of SSI). Post-discharge monitoring showed an increased detection of SSI incidence. Post-discharge monitoring is useful to analyze the real trend of SSI, and evaluate improvement actions. Post-discharge follow-up methods need to standardised. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  11. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  12. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  13. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  14. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  15. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  16. IMPACT OF PARTIAL KANGAROO MOTHER CARE ON GROWTH RATES AND DURATION OF HOSPITAL STAY OF LOW BIRTH WEIGHT INFANTS AT THE KENYATTA NATIONAL HOSPITAL, NAIROBI.

    PubMed

    Mwendwa, A C; Musoke, R N; Wamalwa, D C

    2012-02-01

    To determine the effect of partial Kangaroo Mother Care (KMC) on growth rates and duration of hospital stay of Low Birth Weight (LBW) infants. Unblinded, randomised clinical controlled trial. Kenyatta National Hospital, Nairobi, Kenya. Over a nine month period, consecutive recruitment of eligible LBW infants weighing 1000 g to 1750 g was done until a sample of 166 infants was reached. Kangaroo mother care was practised over an eight hour period per day for the intervention group while the controls remained in incubators or cots. Weight, head circumference, and mid upper arm circumference were monitored for all infants till discharge at 1800 g. Of the 166 infants recruited 157 were followed up to discharge. Baseline characteristics were similar for the two groups except for mother's age, with the KMC group mothers having a mean age of 26.5 years while the control group mothers had a mean age of 24 years, (p = 0.04). The KMC group had significantly higher growth rates as shown by the higher mean weight gain of 22.5 g/kg/day compared with 16.7g/kg/day for the control group, (p < 0.001); higher mean head circumference gain of 0.91 cm/week compared with 0.54 cm/week for the control group, (p < 0.001) and higher mean mid upper arm circumference gain of 0.76 cm/week compared with 0.48 cm/week for the control group, (p = 0.002). Although overall duration of stay was similar between study arms, when infants were stratified into those above or below 1500 g KMC infants' duration of stay was significantly shorter than those in regular care. Using logistic regression, KMCwas the strongest predictor formeanweight, meanhead circumference and mean MUAC gain while mother's age (older) was the strongest predictor for mean duration of stay with KMC being an independent predictor of duration of stay. Low birth weight infants in this cohort achieved rates of growth within the recommended intrauterine growth but babies managed using partial KMC grew faster and were thus discharged earlier than those on standard of care. Since partial KMC was beneficial, it should be fully implemented for all eligible infants.

  17. The association between renal recovery after acute kidney injury and long-term mortality after transcatheter aortic valve replacement.

    PubMed

    Thongprayoon, Charat; Cheungpasitporn, Wisit; Srivali, Narat; Kittanamongkolchai, Wonngarm; Sakhuja, Ankit; Greason, Kevin L; Kashani, Kianoush B

    2017-01-01

    This study aimed to examine the association between renal recovery status at hospital discharge after acute kidney injury (AKI) and long-term mortality following transcatheter aortic valve replacement (TAVR). We screened all adult patients who survived to hospital discharge after TAVR for aortic stenosis at a quaternary referral medical center from January 1, 2008, through June 30, 2014. An AKI was defined as an increase in serum creatinine level of 0.3 mg/dL or a relative increase of 50% from baseline. Renal outcome at the time of discharge was evaluated by comparing the discharge serum creatinine level to the baseline level. Complete renal recovery was defined as no AKI at discharge, whereas partial renal recovery was defined as AKI without a need for renal replacement therapy at discharge. No renal recovery was defined as a need for renal replacement therapy at discharge. The study included 374 patients. Ninty-eight (26%) patients developed AKI during hospitalization: 55 (56%) had complete recovery; 39 (40%), partial recovery; and 4 (4%), no recovery. AKI development was significantly associated with increased risk of 2-year mortality (hazard ratio [HR], 2.20 [95% CI, 1.37-3.49]). For patients with AKI, the 2-year mortality rate for complete recovery was 34%; for partial recovery, 43%; and for no recovery, 75%; compared with 20% for patients without AKI (P < .001). In adjusted analysis, complete recovery (HR, 1.87 [95% CI, 1.03-3.23]); partial recovery (HR, 2.65 [95% CI, 1.40-4.71]) and no recovery (HR, 10.95 [95% CI, 2.59-31.49]) after AKI vs no AKI were significantly associated with increased risk of 2-year mortality. The mortality rate increased for all patients with AKI undergoing TAVR. A reverse correlation existed for progressively higher risk of death and the extent of AKI recovery.

  18. Feasibility study on partial insulation winding technique for the development of self-protective MgB2 magnet

    NASA Astrophysics Data System (ADS)

    Kim, Y. G.; Kim, J. C.; Kim, J. M.; Yoo, B. H.; Hwang, D. Y.; Lee, H. G.

    2018-06-01

    This study investigates the feasibility of using the partial insulation winding technique for the development of a self-protective MgB2 MRI magnet with a fast charge-discharge rate. Charge-discharge and quench tests for a prototype PI MgB2 magnet confirmed that the magnet was successfully operated at full-field performance and exhibited self-protecting behavior in the event of a quench. Nonetheless, the required time to charge the 0.5-T/300-mm PI MgB2 magnet was almost five days, implying that the charge-discharge delay of the PI MgB2 magnet still needs to be ameliorated further to develop a real-scale MgB2 MRI magnet with a fast charge-discharge rate.

  19. The effects of the distribution pattern of multiple voids within LDPE on partial discharge characteristics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, D.S.; Han, M.K.; Lee, J.H.

    1996-12-31

    In this paper, the authors have investigated effects of the arrangement of the voids in LDPE samples on PD characteristics, such as phase-related magnitude of PD, number of discharges. The differences of the PD patterns may be attributed to the arrangements of the voids. They have also employed available statistical operators, such as discharge factor and cross correlation factor in order to analyze the PD characteristics. The authors could conclude that partial discharge characteristics show quite different patterns due to the arrangements of voids in spite of the same size. The experimental results suggest that it is important to knowmore » the arrangements of the multiple voids as well as to obtain the information about the number of defects in the insulators.« less

  20. Partial discharge testing under direct voltage conditions

    NASA Technical Reports Server (NTRS)

    Bever, R. S.; Westrom, J. L.

    1982-01-01

    DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelerated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.

  1. A Comparison of Inductive Sensors in the Characterization of Partial Discharges and Electrical Noise Using the Chromatic Technique.

    PubMed

    Ardila-Rey, Jorge Alfredo; Montaña, Johny; de Castro, Bruno Albuquerque; Schurch, Roger; Covolan Ulson, José Alfredo; Muhammad-Sukki, Firdaus; Bani, Nurul Aini

    2018-03-29

    Partial discharges (PDs) are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power cables. Generally, the classical phase-resolved partial discharge (PRPD) patterns are used to perform the identification of the type of PD source when they are related to a specific degradation process and when the electrical noise level is low compared to the magnitudes of the PD signals. However, in practical applications such as measurements carried out in the field or in industrial environments, several PD sources and large noise signals are usually present simultaneously. In this study, three different inductive sensors have been used to evaluate and compare their performance in the detection and separation of multiple PD sources by applying the chromatic technique to each of the measured signals.

  2. Fiber Optic Sensor for Acoustic Detection of Partial Discharges in Oil-Paper Insulated Electrical Systems

    PubMed Central

    Posada-Roman, Julio; Garcia-Souto, Jose A.; Rubio-Serrano, Jesus

    2012-01-01

    A fiber optic interferometric sensor with an intrinsic transducer along a length of the fiber is presented for ultrasound measurements of the acoustic emission from partial discharges inside oil-filled power apparatus. The sensor is designed for high sensitivity measurements in a harsh electromagnetic field environment, with wide temperature changes and immersion in oil. It allows enough sensitivity for the application, for which the acoustic pressure is in the range of units of Pa at a frequency of 150 kHz. In addition, the accessibility to the sensing region is guaranteed by immune fiber-optic cables and the optical phase sensor output. The sensor design is a compact and rugged coil of fiber. In addition to a complete calibration, the in-situ results show that two types of partial discharges are measured through their acoustic emissions with the sensor immersed in oil. PMID:22666058

  3. Measuring the degradation level of polymer films subjected to partial discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bozzo, R.; Gemme, C.; Guastavino, F.

    1996-12-31

    Polymer films have been subjected to partial discharge (PD) aging. It is shown that statistical quantities derived from partial discharges patterns can be related to test conditions, film characteristics and degradation level. PDs have been measured by means of a digital system. Several resulting PD patterns have been elaborated and about 50 derived and statistical quantities have been obtained for each pattern. The effects of the test conditions on the derived quantities has been studied with relevance to the following items: To recognize the kind of film under test; to correlate the value of quantities with the degradation level ofmore » the film (i.e., to focus at the quantities which change with time); to find a link between the quantities values and the test ambient conditions (i.e., relative humidity); to determine the influence of the film thickness; and to evidence the effect of the voltage level.« less

  4. Comparative analysis of cellulose pressboard and aramid paper used in air insulation systems of high-voltage devices

    NASA Astrophysics Data System (ADS)

    Turba, Tomasz; Frącz, Paweł

    2017-10-01

    The paper presents results of a comparative analysis of parameters of two kinds of solid dielectrics used in air insulation systems to prevent occurring partial discharges. The research works regarded materials made of: cellulose pressboard and aramid paper. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage until breakdown occurred in the inhomogeneous environment that was simulated using needle-plate (made of copper) electrode system. The main contribution which resulted from studies is a statement that potential use of aramid paper as a dielectric can extend the life of a high voltage electric device as compared to standard cellulose pressboard usage due to higher electric resistances to breakdown or detection of corona voltage. Results shown that the aramid paper has greater electric resistance to breakdown in comparison to cellulose with no difference between both on detecting corona of partial discharge.

  5. Flight Termination Systems Commonality Standard

    DTIC Science & Technology

    2014-09-01

    input level is increased 60 dB from threshold. Corona : A visible electric discharge resulting from a partial electric breakdown of gases as the...4-49 Figure 4-10. Electrostatic Discharge Test...check channel telemetry output (EFTR) CDR critical design review CFS flight self- discharge in amp-hrs CR remaining capacity for determining

  6. Oak Ridge Reservation annual site environmental report for 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koncinski, W.S.

    1996-09-01

    This report presents the details of the environmental monitoring and management program for the Oak Ridge Reservation. Topics discussed include: site background, climate, and operations; environmental compliance strategies; effluent monitoring; environmental management program including environmental restoration, decontamination and decommissioning, technology development, and public involvement; effluent monitoring of airborne discharges, liquid discharges, toxicity control and monitoring, biological monitoring and abatement; environmental surveillance which encompasses meteorological monitoring, ambient air monitoring, surface water monitoring, soils monitoring, sediment monitoring, and contamination of food stuffs monitoring; radiation doses; chemical exposures; ground water monitoring; and quality assurance.

  7. Water-Surface Elevations, Discharge, and Water-Quality Data for Selected Sites in the Warm Springs Area near Moapa, Nevada

    USGS Publications Warehouse

    Beck, David A.; Ryan, Roslyn; Veley, Ronald J.; Harper, Donald P.; Tanko, Daron J.

    2006-01-01

    The U.S. Geological Survey, in cooperation with Southern Nevada Water Authority and the Nevada Division of Water Resources, operates and maintains a surface-water monitoring network of 6 continuous-record stream-flow gaging stations and 11 partial-record stations in the Warm Springs area near Moapa, Nevada. Permanent land-surface bench marks were installed within the Warm Springs area by the Las Vegas Valley Water District, the Southern Nevada Water Authority, and the U.S. Geological Survey to determine water-surface elevations at all network monitoring sites. Vertical datum elevation and horizontal coordinates were established for all bench marks through a series of Differential Global Positioning System surveys. Optical theodolite surveys were made to transfer Differential Global Positioning System vertical datums to reference marks installed at each monitoring site. The surveys were completed in June 2004 and water-surface elevations were measured on August 17, 2004. Water-surface elevations ranged from 1,810.33 feet above North American Vertical Datum of 1988 at a stream-gaging station in the Pederson Springs area to 1,706.31 feet at a station on the Muddy River near Moapa. Discharge and water-quality data were compiled for the Warm Springs area and include data provided by the U.S. Geological Survey, Nevada Division of Water Resources, U.S. Fish and Wildlife Service, Moapa Valley Water District, Desert Research Institute, and Converse Consultants. Historical and current hydrologic data-collection networks primarily are related to changes in land- and water-use activities in the Warm Springs area. These changes include declines in ranching and agricultural use, the exportation of water to other areas of Moapa Valley, and the creation of a national wildlife refuge. Water-surface elevations, discharge, and water-quality data compiled for the Warm Springs area will help identify (1) effects of changing vegetation within the former agricultural lands, (2) effects of restoration activities in the wildlife refuge, and (3) potential impacts of ground-water withdrawals.

  8. High-voltage spark carbon-fiber sticky-tape data analyzer

    NASA Technical Reports Server (NTRS)

    Yang, L. C.; Hull, G. G.

    1980-01-01

    An efficient method for detecting carbon fibers collected on a stick tape monitor was developed. The fibers were released from a simulated crash fire situation containing carbon fiber composite material. The method utilized the ability of the fiber to initiate a spark across a set of alternately biased high voltage electrodes to electronically count the number of fiber fragments collected on the tape. It was found that the spark, which contains high energy and is of very short duration, is capable of partially damaging or consuming the fiber fragments. It also creates a mechanical disturbance which ejects the fiber from the grid. Both characteristics were helpful in establishing a single discharge pulse for each fiber segment.

  9. [Italian national register of low etiological fraction occupational cancer pursuant to art. 244 of legislative decree n. 81/2008].

    PubMed

    Massari, S; Ippoliti, M; Menegozzo, S; Forastiere, F; Crosignani, P

    2011-01-01

    Legislative decree No. 81/2008 in the article n. 244 states that ISPESL, now INAIL, realizes a register of occupational cancers with low etiological fraction by means of a data collection method based exclusively on voluntary reports by GPs, healthcare and social security agencies (ReNaLOC) and a surveillance cancer monitoring system (OCCAM) based on linkage of routinely available data (cancer registries, hospital discharge records, Italian Social Security archives). ReNaLOC has produced a partial picture of the situation, it includes 1.584 cases as of June 2011. With OCCAM many situations of known risks were identified and others are worthy to be deepen.

  10. Experimental Verification of the Kruskal-Shafranov Stability Limit in Line-Tied Partial Toroidal Plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oz, E.; Myers, C. E.; Yamada, M.

    2011-07-19

    The stability properties of partial toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas, 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kinkmore » instability. Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., qa = 1).« less

  11. Experimental verification of the Kruskal-Shafranov stability limit in line-tied partial-toroidal plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oz, E.; Myers, C. E.; Yamada, M.

    2011-10-15

    The stability properties of partial-toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kink instability.more » Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., q{sub a} = 1).« less

  12. Water Resources Data, New Jersey, Water Year 2002, Volume 1. Surface-Water Data

    USGS Publications Warehouse

    Reed, T.J.; White, B.T.; Centinaro, G.L.; Dudek, J.F.; Spehar, A.B.; Protz, A.R.; Shvanda, J.C.; Watson, A.F.; Holzer, G.K.

    2003-01-01

    Water-resources data for the 2002 Water Year for New Jersey are presented in three volumes, and consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground water. Volume 1 contains discharge records for 93 gaging stations; tide summaries at 31 gaging stations; and stage and contents at 39 lakes and reservoirs. Also included are stage and discharge for 104 crest-stage partial-record stations and stage-only at 31 tidal crest-stage gages. Locations of these sites are shown in figures 8-11. Additional water data were collected at various sites that are not part of the systematic data-collection program. Discharge measurements were made at 201 low-flow partial-record stations and 121 miscellaneous sites.

  13. Electrodeless discharge lamp is easily started, has high stability

    NASA Technical Reports Server (NTRS)

    Bell, W. E.; Bloom, A. L.

    1966-01-01

    Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.

  14. EPA NetDMR CROMERR System Checklist

    EPA Pesticide Factsheets

    The Network Disharge Monitoring Report (NetDMR) electronic reporting system is used for the receipt of discharge monitoring reports (DMRs) under the National Pollutant Discharge Elimination System (NPDES) program,

  15. Characteristics of Partial Discharge and Ozone Generation for Twisted-pair of Enameled Wires under High-repetitive Impulse Voltage Application

    NASA Astrophysics Data System (ADS)

    Kanazawa, Seiji; Enokizono, Masato; Shibakita, Toshihide; Umehara, Eiji; Toshimitsu, Jun; Ninomiya, Shinji; Taniguchi, Hideki; Abe, Yukari

    In recent years, inverter drive machines such as a hybrid vehicle and an electric vehicle are operated under high voltage pulse with high repetition rate. In this case, inverter surge is generated and affected the machine operation. Especially, the enameled wire of a motor is deteriorated due to the partial discharge (PD) and finally breakdown of the wire will occur. In order to investigate a PD on a resistant enameled wire, characteristics of PD in the twisted pair sample under bipolar repetitive impulse voltages are investigated experimentally. The relationship between the applied voltage and discharge current was measured at PD inception and extinction, and we estimated the repetitive PD inception and extinction voltages experimentally. The corresponding optical emission of the discharge was also observed by using an ICCD camera. Furthermore, ozone concentration due to the discharge was measured during the life-time test of the resistant enameled wires from a working environmental point of view.

  16. Watershed Characteristics and Pre-Restoration Surface-Water Hydrology of Minebank Run, Baltimore County, Maryland, Water Years 2002-04

    USGS Publications Warehouse

    Doheny, Edward J.; Starsoneck, Roger J.; Striz, Elise A.; Mayer, Paul M.

    2006-01-01

    Stream restoration efforts have been ongoing in Maryland since the early 1990s. Physical stream restoration often involves replacement of lost sediments to elevate degraded streambeds, re-establishment of riffle-pool sequences along the channel profile, planting vegetation in riparian zones, and re-constructing channel banks, point bars, flood plains, and stream-meanders. The primary goal of many restoration efforts is to re-establish geomorphic stability of the stream channel and reduce erosive energy from urban runoff. Monitoring streams prior to and after restoration could help quantify other possible benefits of stream restoration, such as improved water quality and biota. This report presents general watershed characteristics associated with the Minebank Run watershed; a small, urban watershed in the south-central section of Baltimore County, Maryland that was physically restored in phases during 1999, 2004, and 2005. The physiography, geology, hydrology, land use, soils, and pre-restoration geomorphic setting of the unrestored stream channel are discussed. The report describes a reach of Minebank Run that was selected for the purpose of collecting several types of environmental data prior to restoration, including continuous-record and partial-record stage and streamflow data, precipitation, and ground-water levels. Examples of surface-water data that were collected in and near the study reach during water years 2002 through 2004, including continuous-record streamflow, partial-record stage and discharge, and precipitation, are described. These data were used in analyses of several characteristics of surface-water hydrology in the watershed, including (1) rainfall totals, storm duration, and intensity, (2) instantaneous peak discharge and daily mean discharge, (3) stage-discharge ratings, (4) hydraulic-geometry relations, (5) water-surface slope, (6) time of concentration, (7) flood frequency, (8) flood volume, and (9) rainfall-runoff relations. Several hydrologic characteristics that are typical of urban environments were quantified by these analyses. These include (1) large ratios of peak discharge to daily mean discharge as an indicator of flashiness, (2) consistent shifting of the stage-discharge rating over short periods of time that indicates instability of the stream channel, (3) analyses of hydraulic-geometry relations that indicate mean velocities of 11 feet per second or more while the flow is contained in the stream channel, (4) discharges that are 4 to 5 times larger in Minebank Run for corresponding flood frequency recurrence intervals than in Slade Run, which is a Piedmont watershed of similar size with smaller percentages of urban development, and (5) flood waves that can travel through the stream channel at a velocity of 412 feet per minute, or 6.9 feet per second.

  17. The recalculation of the original pulse produced by a partial discharge

    NASA Technical Reports Server (NTRS)

    Tanasescu, F.

    1978-01-01

    The loads on a dielectric or an insulation arrangement cannot be precisely rated without properly assessing the manner in which a pulse produced by a partial discharge is transmitted from the point of the event to the point where it is recorded. A number of analytical and graphic methods are presented, and computer simulations are used for specific cases of a few measurement circuits. It turns out to be possible to determine the effect of each circuit element and thus make some valid corrections.

  18. Effects of Electrical Insulation Breakdown Voltage And Partial Discharge

    NASA Astrophysics Data System (ADS)

    Bahrim, F. S.; Rahman, N. F. A.; Haris, H. C. M.; Salim, N. A.

    2018-03-01

    During the last few decades, development of new materials using composite materials has been of much interest. The Cross-linked Polyethylene (XLPE) which is insulated power cables has been widely used. This paper describes the theoretical analysis, fundamental experiments and application experiments for the XLPE cable insulation. The composite that has been tested is a commercial XLPE and Polypropylene with 30% fiber glass. The results of breakdown strength and partial discharge (PD) behavior described the insulating performance of the composite.

  19. DISCHARGE AND DEPTH BEHIND A PARTIALLY BREACHED DAM.

    USGS Publications Warehouse

    Chen, Cheng-lung

    1987-01-01

    The role that the velocity-distribution correction factor plays in the determination of the flood discharge and corresponding flow depth behind a partially breached dam is investigated. Assumption of a uniformly progressive flow for an established dam-break flood in a rectangular channel of infinite extent leads to the formulation of a theoretical relation between the depth and velocity of flow expressed in differential form. Integrating this ordinary differential equation, one can express the velocity in terms of the depth.

  20. Photogenic partial seizures.

    PubMed

    Hennessy, M J; Binnie, C D

    2000-01-01

    To establish the incidence and symptoms of partial seizures in a cohort of patients investigated on account of known sensitivity to intermittent photic stimulation and/or precipitation of seizures by environmental visual stimuli such as television (TV) screens or computer monitors. We report 43 consecutive patients with epilepsy, who had exhibited a significant EEG photoparoxysmal response or who had seizures precipitated by environmental visual stimuli and underwent detailed assessment of their photosensitivity in the EEG laboratory, during which all were questioned concerning their ictal symptoms. All patients were considered on clinical grounds to have an idiopathic epilepsy syndrome. Twenty-eight (65%) patients reported visually precipitated attacks occurring initially with maintained consciousness, in some instances evolving to a period of confusion or to a secondarily generalized seizure. Visual symptoms were most commonly reported and included positive symptoms such as coloured circles or spots, but also blindness and subjective symptoms such as "eyes going funny." Other symptoms described included nonspecific cephalic sensations, deja-vu, auditory hallucinations, nausea, and vomiting. No patient reported any clear spontaneous partial seizures, and there were no grounds for supposing that any had partial epilepsy excepting the ictal phenomenology of some or all of the visually induced attacks. These findings provide clinical support for the physiological studies that indicate that the trigger mechanism for human photosensitivity involves binocularly innervated cells located in the visual cortex. Thus the visual cortex is the seat of the primary epileptogenic process, and the photically triggered discharges and seizures may be regarded as partial with secondary generalization.

  1. A Comparison of Inductive Sensors in the Characterization of Partial Discharges and Electrical Noise Using the Chromatic Technique

    PubMed Central

    Ardila-Rey, Jorge Alfredo; Montaña, Johny; Schurch, Roger; Covolan Ulson, José Alfredo; Bani, Nurul Aini

    2018-01-01

    Partial discharges (PDs) are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power cables. Generally, the classical phase-resolved partial discharge (PRPD) patterns are used to perform the identification of the type of PD source when they are related to a specific degradation process and when the electrical noise level is low compared to the magnitudes of the PD signals. However, in practical applications such as measurements carried out in the field or in industrial environments, several PD sources and large noise signals are usually present simultaneously. In this study, three different inductive sensors have been used to evaluate and compare their performance in the detection and separation of multiple PD sources by applying the chromatic technique to each of the measured signals. PMID:29596337

  2. Detection of incipient defects in cables by partial discharge signal analysis

    NASA Astrophysics Data System (ADS)

    Martzloff, F. D.; Simmon, E.; Steiner, J. P.; Vanbrunt, R. J.

    1992-07-01

    As one of the objectives of a program aimed at assessing test methods for in-situ detection of incipient defects in cables due to aging, a laboratory test system was implemented to demonstrate that the partial discharge analysis method can be successfully applied to low-voltage cables. Previous investigations generally involved cables rated 5 kV or higher, while the objective of the program focused on the lower voltages associated with the safety systems of nuclear power plants. The defect detection system implemented for the project was based on commercially available signal analysis hardware and software packages, customized for the specific purposes of the project. The test specimens included several cables of the type found in nuclear power plants, including artificial defects introduced at various points of the cable. The results indicate that indeed, partial discharge analysis is capable of detecting incipient defects in low-voltage cables. There are, however, some limitations of technical and non-technical nature that need further exploration before this method can be accepted in the industry.

  3. Hyperoxia is Associated with Increased Mortality in Patients Treated with Mild Therapeutic Hypothermia after Sudden Cardiac Arrest

    PubMed Central

    Janz, David R.; Hollenbeck, Ryan D.; Pollock, Jeremy S.; McPherson, John A.; Rice, Todd W.

    2012-01-01

    Objective To determine if higher levels of partial pressure of arterial oxygen are associated with in-hospital mortality and poor neurologic status at hospital discharge in patients treated with mild therapeutic hypothermia after sudden cardiac arrest. Design Retrospective analysis of a prospective cohort study Patients A total of 170 consecutive patients treated with therapeutic hypothermia in the cardiovascular care unit of an academic tertiary care hospital. Interventions None. Measurements and Main Results Of 170 patients, 77 (45.2%) survived to hospital discharge. Survivors had a significantly lower maximum partial pressure of arterial oxygen(198 mmHg, IQR 152.5–282) measured in the first 24 hours following cardiac arrest compared to nonsurvivors (254 mmHg, IQR 172–363, p = .022). A multivariable analysis including age, time to return of spontaneous circulation, the presence of shock, bystander CPR, and initial rhythm revealed that higher levels of the partial pressure of arterial oxygen were significantly associated with increased in-hospital mortality (odds ratio 1.439, 95% confidence interval 1.028–2.015, p = 0.034) and poor neurologic status at hospital discharge (odds ratio 1.485, 95% confidence interval 1.032–2.136, p = 0.033). Conclusions Higher levels of the maximum measured partial pressure of arterial oxygen are associated with increased in-hospital mortality and poor neurologic status on hospital discharge in patients treated with mild therapeutic hypothermia after sudden cardiac arrest. PMID:22971589

  4. Using the tracer-dilution discharge method to develop streamflow records for ice-affected streams in Colorado

    USGS Publications Warehouse

    Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.

    2005-01-01

    Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period, the pumps underdischarged the tracer by 5.8-15.9 percent as compared to the initial pumping rate setting, which may explain some of the error in the tracer-dilution streamflow record as compared to current-meter streamflow record.

  5. Investigation of impurity transport using laser blow-off technique in the HL-2A Ohmic and ECRH plasmas

    NASA Astrophysics Data System (ADS)

    Kai, Zhang; Zheng-Ying, Cui; Ping, Sun; Chun-Feng, Dong; Wei, Deng; Yun-Bo, Dong; Shao-Dong, Song; Min, Jiang; Yong-Gao, Li; Ping, Lu; Qing-Wei, Yang

    2016-06-01

    Impurity transports in two neighboring discharges with and without electron cyclotron resonance heating (ECRH) are studied in the HL-2A tokamak by laser blow-off (LBO) technique. The progression of aluminium ions as the trace impurity is monitored by soft x-ray (SXR) and bolometer detector arrays with good temporal and spatial resolutions. Obvious difference in the time trace of the signal between the Ohmic and ECRH L-mode discharges is observed. Based on the numerical simulation with one-dimensional (1D) impurity transport code STRAHL, the radial profiles of impurity diffusion coefficient D and convective velocity V are obtained for each shot. The result shows that the diffusion coefficient D significantly increases throughout the plasma minor radius for the ECRH case with respect to the Ohmic case, and that the convection velocity V changes from negative (inward) for the Ohmic case to partially positive (outward) for the ECRH case. The result on HL-2A confirms the pump out effect of ECRH on impurity profile as reported on various other devices.

  6. An optimized network for phosphorus load monitoring for Lake Okeechobee, Florida

    USGS Publications Warehouse

    Gain, W.S.

    1997-01-01

    Phosphorus load data were evaluated for Lake Okeechobee, Florida, for water years 1982 through 1991. Standard errors for load estimates were computed from available phosphorus concentration and daily discharge data. Components of error were associated with uncertainty in concentration and discharge data and were calculated for existing conditions and for 6 alternative load-monitoring scenarios for each of 48 distinct inflows. Benefit-cost ratios were computed for each alternative monitoring scenario at each site by dividing estimated reductions in load uncertainty by the 5-year average costs of each scenario in 1992 dollars. Absolute and marginal benefit-cost ratios were compared in an iterative optimization scheme to determine the most cost-effective combination of discharge and concentration monitoring scenarios for the lake. If the current (1992) discharge-monitoring network around the lake is maintained, the water-quality sampling at each inflow site twice each year is continued, and the nature of loading remains the same, the standard error of computed mean-annual load is estimated at about 98 metric tons per year compared to an absolute loading rate (inflows and outflows) of 530 metric tons per year. This produces a relative uncertainty of nearly 20 percent. The standard error in load can be reduced to about 20 metric tons per year (4 percent) by adopting an optimized set of monitoring alternatives at a cost of an additional $200,000 per year. The final optimized network prescribes changes to improve both concentration and discharge monitoring. These changes include the addition of intensive sampling with automatic samplers at 11 sites, the initiation of event-based sampling by observers at another 5 sites, the continuation of periodic sampling 12 times per year at 1 site, the installation of acoustic velocity meters to improve discharge gaging at 9 sites, and the improvement of a discharge rating at 1 site.

  7. Gas pressure and electron density at the level of the active zone of hollow cathode arc discharges

    NASA Technical Reports Server (NTRS)

    Minoo, M. H.

    1984-01-01

    A model for the longitudinal variations of the partial pressures of electrons, ions, and neutral particles is proposed as a result of an experimental study of pressure variations at the level of the active zone as a function of the various discharge parameters of a hollow cathode arc. The cathode region where the temperature passes through its maximum is called active zone. The proposed model embodies the very important variations which the partial electron and neutral particles pressures undergo at the level of the active zone.

  8. Cost efficient environmental survey paths for detecting continuous tracer discharges

    NASA Astrophysics Data System (ADS)

    Alendal, G.

    2017-07-01

    Designing monitoring programs for detecting potential tracer discharges from unknown locations is challenging. The high variability of the environment may camouflage the anticipated anisotropic signal from a discharge, and there are a number of discharge scenarios. Monitoring operations may also be costly, constraining the number of measurements taken. By assuming that a discharge is active, and a prior belief on the most likely seep location, a method that uses Bayes' theorem combined with discharge footprint predictions is used to update the probability map. Measurement locations with highest reduction in the overall probability of a discharge to be active can be identified. The relative cost between reallocating and measurements can be taken into account. Three different strategies are suggested to enable cost efficient paths for autonomous vessels.

  9. Low-flow frequency analyses for streams in west-central Florida

    USGS Publications Warehouse

    Hammett, K.M.

    1985-01-01

    The log-Pearson type III distribution was used for defining low-flow frequency at 116 continuous-record streamflow stations in west-central Florida. Frequency distributions were calculated for 1, 3, 7, 14, 30, 60, 90, 120, and 183 consecutive-day periods for recurrence intervals of 2, 5, 10, and 20 years. Discharge measurements at more than 100 low-flow partial-record stations and miscellaneous discharge-measurement stations were correlated with concurrent daily mean discharge at continuous-record stations. Estimates of the 7-day, 2-year; 7-day, 10-year; 30-day, 2-year; and 30-day, 10-year discharges were made for most of the low-flow partial-record and miscellaneous discharge-measurement stations based on those correlations. Multiple linear-regression analysis was used in an attempt to mathematically relate low-flow frequency data to basin characteristics. The resulting equations showed an apparent bias and were considered unsatisfactory for use in estimating low-flow characteristics. Maps of the 7-day, 10-year and 30-day, 10-year low flows are presented. Techniques that can be used to estimate low-flow characteristics at an ungaged site are also provided. (USGS)

  10. 40 CFR Appendix B to Part 434 - Baseline Determination and Compliance Monitoring for Pre-existing Discharges at Remining Operations

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Monitoring for Pre-existing Discharges at Remining Operations B Appendix B to Part 434 Protection of.... B Appendix B to Part 434—Baseline Determination and Compliance Monitoring for Pre-existing... monthly (single-observation) procedure and an annual procedure shall be applied, as described below. b. In...

  11. Difficulty in clinical identification of neonatal seizures: an EEG monitor study.

    PubMed Central

    Fenichel, G. M.

    1987-01-01

    Seventeen newborns were monitored for 24 hours using a three-channel ambulatory EEG (A/EEG). All newborns were thought to be having subtle seizures by the nursery staff. Fifteen of the 17 newborns were recorded as having 1-30 clinical seizures during the time of monitoring. Only one newborn had clinically identified seizures associated with A/EEG discharges. The seizures were characterized by eye rolling. Fifty-two episodes (thought to be seizures) of lip smacking, bicycling, jerking, fisting, staring, stiffening, or any combination of the above occurred in eight newborns without an associated discharge on A/EEG. However, two of the eight had seizure discharges at other times, not associated with any clinical manifestation. Seventy-four apnea spells, thought to be possible seizures, occurred in seven newborns. None was associated with discharges on A/EEG, but one of these newborns had 50 A/EEG discharges unrelated to apnea or other clinical manifestations. PMID:3577211

  12. Occurrence of epileptiform discharges and sleep during EEG recordings in children after melatonin intake versus sleep-deprivation.

    PubMed

    Gustafsson, Greta; Broström, Anders; Ulander, Martin; Vrethem, Magnus; Svanborg, Eva

    2015-08-01

    To determine if melatonin is equally efficient as partial sleep deprivation in inducing sleep without interfering with epileptiform discharges in EEG recordings in children 1-16 years old. We retrospectively analysed 129 EEGs recorded after melatonin intake and 113 EEGs recorded after partial sleep deprivation. Comparisons were made concerning occurrence of epileptiform discharges, the number of children who fell asleep and the technical quality of EEG recordings. Comparison between different age groups was also made. No significant differences were found regarding occurrence of epileptiform discharges (33% after melatonin intake, 36% after sleep deprivation), or proportion of unsuccessful EEGs (8% and 10%, respectively). Melatonin and sleep deprivation were equally efficient in inducing sleep (70% in both groups). Significantly more children aged 1-4 years obtained sleep after melatonin intake in comparison to sleep deprivation (82% vs. 58%, p⩽0.01), and in comparison to older children with melatonin induced sleep (58-67%, p⩽0.05). Sleep deprived children 9-12 years old had higher percentage of epileptiform discharges (62%, p⩽0.05) compared to younger sleep deprived children. Melatonin is equally efficient as partial sleep deprivation to induce sleep and does not affect the occurrence of epileptiform discharges in the EEG recording. Sleep deprivation could still be preferable in older children as melatonin probably has less sleep inducing effect. Melatonin induced sleep have advantages, especially in younger children as they fall asleep easier than after sleep deprivation. The procedure is easier for the parents than keeping a young child awake for half the night. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  13. 33 CFR 157.02 - Incorporation by reference: Where can I get a copy of the publications mentioned in this part?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Item 11, Guidelines and Specifications for Oil Discharge Monitoring and Control Systems for Oil Tankers... Monitoring and Control Systems for Oil Tankers (“A.586(14)”), incorporation by reference approved for § 157... 1983, Guidelines for Plan Approval and Installation Survey of Oil Discharge Monitoring and Control...

  14. 33 CFR 157.02 - Incorporation by reference: Where can I get a copy of the publications mentioned in this part?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Item 11, Guidelines and Specifications for Oil Discharge Monitoring and Control Systems for Oil Tankers... Monitoring and Control Systems for Oil Tankers (“A.586(14)”), incorporation by reference approved for § 157... 1983, Guidelines for Plan Approval and Installation Survey of Oil Discharge Monitoring and Control...

  15. 33 CFR 157.02 - Incorporation by reference: Where can I get a copy of the publications mentioned in this part?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Item 11, Guidelines and Specifications for Oil Discharge Monitoring and Control Systems for Oil Tankers... Monitoring and Control Systems for Oil Tankers (“A.586(14)”), incorporation by reference approved for § 157... 1983, Guidelines for Plan Approval and Installation Survey of Oil Discharge Monitoring and Control...

  16. 33 CFR 157.02 - Incorporation by reference: Where can I get a copy of the publications mentioned in this part?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Item 11, Guidelines and Specifications for Oil Discharge Monitoring and Control Systems for Oil Tankers... Monitoring and Control Systems for Oil Tankers (“A.586(14)”), incorporation by reference approved for § 157... 1983, Guidelines for Plan Approval and Installation Survey of Oil Discharge Monitoring and Control...

  17. An experimental system for coiled tubing partial underbalanced drilling (CT-PUBD) technique

    NASA Astrophysics Data System (ADS)

    Shi, H. Z.; Ji, Z. S.; Zhao, H. Q.; Chen, Z. L.; Zhang, H. Z.

    2018-05-01

    To improve the rate of penetration (ROP) in hard formations, a new high-speed drilling technique called Coiled Tubing Partial Underbalanced Drilling (CT-PUBD) is proposed. This method uses a rotary packer to realize an underbalanced condition near the bit by creating a micro-annulus and an overbalanced condition at the main part of the annulus. A new full-scale laboratory experimental system is designed and set up to study the hydraulic characteristics and drilling performance of this method. The system is composed of a drilling system, circulation system, and monitor system, including three key devices, namely, cuttings discharge device, rotary packer, and backflow device. The experimental results showed that the pressure loss increased linearly with the flow rate of the drilling fluid. The high drilling speed of CT-PUBD proved it a better drilling method than the conventional drilling. The experimental system may provide a fundamental basis for the research of CT-PUBD, and the results proved that this new method is feasible in enhancing ROP and guaranteeing the drilling safety.

  18. Hydraulic reliability of a horizontal wetland for wastewater treatment in Sicily.

    PubMed

    Marzo, A; Ventura, D; Cirelli, G L; Aiello, R; Vanella, D; Rapisarda, R; Barbagallo, S; Consoli, S

    2018-09-15

    The purpose of this study was to evaluate how the hydraulic behavior of a horizontal subsurface wetland (HF), that is part of the hybrid wetland (hybrid-TW) of the IKEA® store in Eastern Sicily (Italy), influences the overall wastewater treatment performance. The HF unit experiences frequent overloading peaks due to the extreme variability in the number of visitors at the store, and after 2 years of operation it showed signals of partial clogging at the inlet area. The hydraulics of the HF unit has been monitored through measurements of hydraulic conductivity at saturation (Ks), tracer tests, and geophysical (i.e. electrical resistivity tomography-ERT) measurements carried out during the years 2016 and 2017. Results indicated a general good agreement between the performed measurement techniques, thus their combination, if adequately performed and calibrated, might be a reliable tool for detecting those wetland areas mainly affected by clogging conditions. The results also indicated that partial clogging had no significant effect on the quality of the discharged water. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Effect of toughened epoxy resin on partial discharge at solid-solid interface

    NASA Astrophysics Data System (ADS)

    Li, Manping; Wu, Kai; Zhang, Zhao; Cheng, Yonghong

    2017-02-01

    A series of solid-solid interfaces, consisting of ceramic-epoxy resin interface samples with a tip-plate electrode, were investigated by performing partial discharge tests and real-time electrical tree observations. A toughening agent was added to the epoxy resin at different ratios for comparison. The impact strength, differential scanning calorimetry (DSC) and dielectric properties of the cured compositions and ceramic were tested. The electric field strength at the tip was calculated based on Maxwell’s theory. The test results show that the addition of a toughener can improve the impact strength of epoxy resin but it decreases the partial discharge inception voltage (PDIV) of the interface sample. At the same time, toughening leads to complex branches of the electrical tree. The simulation result suggests that this reduction of the PDIV cannot be explained by a change of permittivity due to the addition of a toughening agent. The microstructural change caused by toughening was considered to be the key factor for lower PDIV and complex electrical tree branches. Supported by China Academy of Engineering Physics (Project 2014B05005).

  20. Caracterisation des signatures de decharges partielles en utilisant une nouvelle generation de coupleurs piezoelectriques

    NASA Astrophysics Data System (ADS)

    Danouj, Boujemaa

    An important issue affecting the sustainability of power transformers is systematic and progressive deterioration of the insulation system by the action of partial discharge. Ideally, it is appropriate to use on line, non-destructive techniques for detection and diagnosis of failures related to insulation systems, in order to determine whether preventive maintenance action is required. Thus, huge material losses can be saved (spared), while improving reliability and system availability. Based on a new generation of piezoelectric sensors (High Temperature Ultrasonic Transducers HTUTs), recently developed by the Industrial Materials Institute (IMI) in Boucherville (Qc, Canada) and offers very interesting features (broad band frequency response, flexible, miniature, economic, etc..), we propose in this thesis an investigation on the applicability of this technology to the problematic of partial discharges. This work presents an analysis of the metrological performance of these sensors and demonstrated empirically the consistency of their measures. It outlines the results of validation from a comparative study with the measures of a standard detection circuit. In addition, it also presents the potential of these sensors to locate partial discharge source position by acoustic emission.

  1. Options and limits of quantitative and qualitative online-monitoring of industrial discharges into municipal sewage systems.

    PubMed

    Hoppe, H; Messmann, S; Giga, A; Grüning, H

    2009-01-01

    In some cities, industrial enterprises' discharges into municipal sewage systems have a major impact on the quantity and quality of inflows to the municipal treatment plants. In many cases, industrial discharges stand out on account of the great fluctuations in their volumetric rates of flow, pollution loads and temperatures. As a result, these discharges put a great strain on the sewage system, the treatment plant, and ultimately the receiving waters. The enterprises concerned have to pay the treatment plant operators fees based on the load and/or volume discharged. In most cases, qualitative monitoring operations merely consist of spot checks. This means that continuously surveillance is not possible and infringements of the permissible limit values are only discovered by accident. If impermissible discharges are carried out that may be susceptible to causing a treatment plant failure, the rapid initiation of countermeasures is not possible. Hence, spectrometer probes and mobile flowmeters were used in order to determine volumetric rates of flow, COD concentrations, and ultimately the loads discharged. The possibilities for, and limits to, online monitoring as well as shortcomings of spot-checks are discussed in the course of this paper, which also includes an uncertainty analysis.

  2. Surface water discharge and salinity monitoring of coastal estuaries in Everglades National Park, USA, in support of the Comprehensive Everglades Restoration Plan

    USGS Publications Warehouse

    Woods, Jeff

    2010-01-01

    Discharge and salinity were measured along the southwest and the southeast coast of Florida in Everglades National Park (ENP) within several rivers and creeks from 1996 through 2008. Data were collected using hydro-acoustic instruments and continuous water-quality monitors at fixed monitoring stations. Water flowed through ENP within two distinct drainage basins; specifically, Shark Slough and Taylor Slough. Discharge to the southwest coast through Shark Slough was substantially larger than discharge to the southeast coast through Taylor Slough. Correlation analysis between coastal flows and regulated flows at water-management structures upstream from ENP suggests rainfall has a larger impact on discharge through Shark Slough than releases from the S-12 water management structures. In contrast, flow releases from water management structures upstream from Taylor Slough appear to be more closely related to discharge along the southeast coast. Salinity varied within a wide range (0 to 50 parts per thousand) along both coastlines. Periods of hypersalinity were greater along the southeast coast due to shallow compartmentalized basins within Florida Bay, which restrict circulation.

  3. A single overnight stay is possible for most patients undergoing robotic partial nephrectomy.

    PubMed

    Abaza, Ronney; Shah, Ketul

    2013-02-01

    To evaluate establishment of overnight stay only as sufficient after robotic partial nephrectomy (RPN). Stated benefits of minimally invasive surgery include reduced hospitalization, but published hospital stays after laparoscopic or robotic partial nephrectomy are not significantly less than with open surgery. We developed a clinical pathway targeting discharge on postoperative day (POD) 1 after RPN of any complexity. We reviewed all RPNs by a single surgeon since instituting our clinical pathway, including ambulation and diet the night of surgery, avoidance of intravenous narcotics and drains, and catheter removal on POD 1 before discharge. Targeted discharge was not modified regardless of RPN complexity. A total of 150 consecutive patients underwent 160 RPNs with 35 hilar tumors and 26 with segmental, and 33 with no artery clamping. Three had solitary kidneys, and 8 underwent multiple (range, 2-4) RPNs. Mean patient age was 57 years (range, 22-89 years), and body mass index was 32 kg/m(2) (range, 18-54 kg/m(2)). Mean tumor size was 3.6 cm (range, 1.0-11.0; median, 3.2 cm), and the RENAL (radius, exophytic/endophytic, nearness to collecting system, anterior/posterior, and location) nephrometry score was 8 (range, 4-12; median, 8). Mean warm ischemia time was 12.1 minutes (range, 0-30.0 minutes). Mean preoperative and discharge creatinine were 0.9 mg/dL (range, 0.43-2.79 mg/dL) and 1.13 mg/dL (range, 0.56-2.93 mg/dL). All patients ambulated on POD 0. One patient required one dose of intravenous narcotic. Mean length of stay was 1.1 days, with 145 (97%) discharged on POD 1, of which only 4 (2.7%) were readmitted within 30 days. Discharge on POD 1 is feasible in most RPN patients regardless of complexity. Readmission rate was low, indicating that longer admissions may not prevent complications when patients meeting discharge criteria go home on POD 1. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Silver-silver sulfate reference electrodes for use in lead-acid batteries

    NASA Astrophysics Data System (ADS)

    Ruetschi, Paul

    Electrochemical properties of silver-silver sulfate reference electrodes for lead-acid batteries are described, and the following possible applications discussed: Determination of individual capacities of positive and negative plates. Monitoring individual electrode behavior during deep discharge and cell reversal. Optimization charge or discharge parameters, by controlling the current such that pre-determined limits of positive or negative half-cell potential are respected. Observation of acid concentration differences, for example due to acid stratification, by measuring diffusion potentials (concentration-cell voltages). Detection of defective cells, and defective plate sets, in a string of cells, at the end of their service life. Silver-silver sulfate reference electrodes, permanently installed in lead-acid cells, may be a means to improve battery management, and therewith to improve reliability and service life. In vented batteries, reference electrodes may be used to limit positive plate polarization during charge, or float-charge. Limiting the positive half-cell potential to an upper, pre-set value would permit to keep anodic corrosion as low as possible. During cycling, discharge could be terminated when the half-cell potential of the positive electrode has dropped to a pre-set limit. This would prevent excessive discharge of the positive electrodes, which could result in an improvement of cycle life. In valve-regulated batteries, reference electrodes may be used to adjust float-charge conditions such as to assure sufficient cathodic polarization of the negative electrodes, in order to avoid sulfation. The use of such reference electrodes could be beneficial particularly in multi-cell batteries, with overall voltages above 12 V, operated in a partial-state-of-charge.

  5. Nutrient intake, peripheral edema, and weight change in elderly recuperative care patients.

    PubMed

    Sullivan, Dennis H; Johnson, Larry E; Dennis, Richard A; Roberson, Paula K; Garner, Kimberly K; Padala, Prasad R; Padala, Kalpana P; Bopp, Melinda M

    2013-06-01

    It is unclear whether serial measures of body weight are valid indicators of nutritional status in older patients recovering from illness. Objectives. Investigate the relative influence of nutrient intake and changes in peripheral edema on weight change. A prospective cohort study of 404 older men (mean age = 78.7±7.5 years) admitted to a transitional care unit of a Department of Veterans Affairs nursing home. Body weight and several indicators of lower extremity edema were measured at both unit admission and discharge. Complete nutrient intake assessments were performed daily. Over a median length of stay of 23 days (interquartile range: 15-41 days), 216 (53%) participants gained or lost more than or equal to 2.5% of their body weight. Two hundred eighty-two (70%) participants had recognizable lower extremity pitting edema at admission and/or discharge. The amount of weight change was strongly and positively correlated with multiple indicators of both nutrient intake and the change in the amount of peripheral edema. By multivariable analysis, the strongest predictor of weight change was maximal calf circumference change (partial R (2) = .35, p < .0001), followed by average daily energy intake (partial R (2) = .14, p < .0001), and the interaction of energy intake by time (partial R (2) = .02, p < .0001). Many older patients either gain or lose a significant amount of weight after admission to a transitional care unit. Because of the apparent high prevalence of co-occurring changes in total body water, the weight changes do not necessarily represent changes in nutritional status. Although repeat calf circumference measurements may provide some indication as to how much of the weight change is due to changes in body water, there is currently no viable alternative to monitoring the nutrient intake of older recuperative care patients in order to ensure that their nutrient needs are being met.

  6. Fiber Fabry-Perot sensors for detection of partial discharges in power transformers.

    PubMed

    Yu, Bing; Kim, Dae Woong; Deng, Jiangdong; Xiao, Hai; Wang, Anbo

    2003-06-01

    A diaphragm-based interferometric fiberoptic sensor that uses a low-coherence light source was designed and tested for on-line detection of the acoustic waves generated by partial discharges inside high-voltage power transformers. The sensor uses a fused-silica diaphragm and a single-mode optical fiber encapsulated in a fused-silica glass tube to form an extrinsic Fabry-Perot interferometer, which is interrogated by low-coherence light. Test results indicate that these fiber optic acoustic sensors are capable of faithfully detecting acoustic signals propagating inside transformer oil with high sensitivity and wide bandwidth.

  7. Optical fiber sensor of partial discharges in High Voltage DC experiments

    NASA Astrophysics Data System (ADS)

    Búa-Núñez, I.; Azcárraga-Ramos, C. G.; Posada-Román, J. E.; Garcia-Souto, J. A.

    2014-05-01

    A setup simulating High Voltage DC (HVDC) transformers barriers was developed to demonstrate the effectiveness of an optical fiber (OF) sensor in detecting partial discharges (PD) under these peculiar conditions. Different PD detection techniques were compared: electrical methods, and acoustic methods. Standard piezoelectric sensors (R15i-AST) and the above mentioned OF sensors were used for acoustic detection. The OF sensor was able to detect PD acoustically with a sensitivity better than the other detection methods. The multichannel instrumentation system was tested in real HVDC conditions with the aim of analyzing the behavior of the insulation (mineral oil/pressboard).

  8. 10 CFR 431.282 - Test Procedures [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp..., current, and waveform) for starting and operating. High intensity discharge lamp means an electric... light is produced by radiation from mercury typically operating at a partial vapor pressure in excess of...

  9. Mass separation of deuterium and helium with conventional quadrupole mass spectrometer by using varied ionization energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Yaowei; Hu, Jiansheng, E-mail: hujs@ipp.ac.cn; Wan, Zhao

    2016-03-15

    Deuterium pressure in deuterium-helium mixture gas is successfully measured by a common quadrupole mass spectrometer (model: RGA200) with a resolution of ∼0.5 atomic mass unit (AMU), by using varied ionization energy together with new developed software and dedicated calibration for RGA200. The new software is developed by using MATLAB with the new functions: electron energy (EE) scanning, deuterium partial pressure measurement, and automatic data saving. RGA200 with new software is calibrated in pure deuterium and pure helium 1.0 × 10{sup −6}–5.0 × 10{sup −2} Pa, and the relation between pressure and ion current of AMU4 under EE = 25 eVmore » and EE = 70 eV is obtained. From the calibration result and RGA200 scanning with varied ionization energy in deuterium and helium mixture gas, both deuterium partial pressures (P{sub D{sub 2}}) and helium partial pressure (P{sub He}) could be obtained. The result shows that deuterium partial pressure could be measured if P{sub D{sub 2}} > 10{sup −6} Pa (limited by ultimate pressure of calibration vessel), and helium pressure could be measured only if P{sub He}/P{sub D{sub 2}} > 0.45, and the measurement error is evaluated as 15%. This method is successfully employed in EAST 2015 summer campaign to monitor deuterium outgassing/desorption during helium discharge cleaning.« less

  10. Identifying trends in sediment discharge from alterations in upstream land use

    USGS Publications Warehouse

    Parker, R.S.; Osterkamp, W.R.

    1995-01-01

    Environmental monitoring is a primary reason for collecting sediment data. One emphasis of this monitoring is identification of trends in suspended sediment discharge. A stochastic equation was used to generate time series of annual suspended sediment discharges using statistics from gaging stations with drainage areas between 1606 and 1 805 230 km2. Annual sediment discharge was increased linearly to yield a given increase at the end of a fixed period and trend statistics were computed for each simulation series using Kendal's tau (at 0.05 significance level). A parameter was calculated from two factors that control trend detection time: (a) the magnitude of change in sediment discharge, and (b) the natural variability of sediment discharge. In this analysis the detection of a trend at most stations is well over 100 years for a 20% increase in sediment discharge. Further research is needed to assess the sensitivity of detecting trends at sediment stations.

  11. Cost-effectiveness of the US Geological Survey stream-gaging program in Arkansas

    USGS Publications Warehouse

    Darling, M.E.; Lamb, T.E.

    1984-01-01

    This report documents the results of the cost-effectiveness of the stream-gaging program in Arkansas. Data uses and funding sources were identified for the daily-discharge stations. All daily-discharge stations were found to be in one or more data use categories, and none were candidates for alternate methods which would result in discontinuation or conversion to a partial record station. The cost for operation of daily-discharge stations and routing costs to partial record stations, crest gages, pollution control stations as well as seven recording ground-water stations was evaluated in the Kalman-Filtering Cost-Effective Resource allocation (K-CERA) analysis. This operation under current practices requires a budget of $292,150. The average standard error of estimate of streamflow record for the Arkansas District was analyzed at 33 percent.

  12. Fabrication of optical fiber sensor based on double-layer SU-8 diaphragm and the partial discharge detection

    NASA Astrophysics Data System (ADS)

    Shang, Ya-na; Ni, Qing-yan; Ding, Ding; Chen, Na; Wang, Ting-yun

    2015-01-01

    In this paper, a partial discharge detection system is proposed using an optical fiber Fabry-Perot (FP) interferometric sensor, which is fabricated by photolithography. SU-8 photoresist is employed due to its low Young's modulus and potentially high sensitivity for ultrasound detection. The FP cavity is formed by coating the fiber end face with two layers of SU-8 so that the cavity can be controlled by the thickness of the middle layer of SU-8. Static pressure measurement experiments are done to estimate the sensing performance. The results show that the SU-8 based sensor has a sensitivity of 154.8 nm/kPa, which is much higher than that of silica based sensor under the same condition. Moreover, the sensor is demonstrated successfully to detect ultrasound from electrode discharge.

  13. Voice Enabled Framework to Support Post-Surgical Discharge Monitoring

    PubMed Central

    Blansit, Kevin; Marmor, Rebecca; Zhao, Beiqun; Tien, Dan

    2017-01-01

    Unplanned surgical readmissions pose a challenging problem for the American healthcare system. We propose to combine consumer electronic voice recognition technology with the FHIR standard to create a post-surgical discharge monitoring app to identify and alert physicians to a patient’s deteriorating status. PMID:29854267

  14. Water Resources Data, New Jersey, Water Year 2003; Volume 1. Surface-Water Data

    USGS Publications Warehouse

    Reed, T.J.; White, B.T.; Centinaro, G.L.; Dudek, J.F.; Protz, A.R.; Shvanda, J.C.; Watson, A.F.

    2004-01-01

    Water-resources data for the 2003 Water Year for New Jersey are presented in three volumes, and consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground water. Volume 1 contains discharge records for 100 gaging stations; tide summaries at 29 tidal gaging stations; and stage and contents at 39 lakes and reservoirs. Also included are stage and discharge for 106 crest-stage partial-record stations, stage-only at 33 tidal crest-stage gages, and discharge for 142 low-flow partial- record stations. Locations of these sites are shown in figures 8-11. Additional discharge measurements were made at 143 miscellaneous sites that are not part of the systematic data-collection program. Discontinued station tables for gaging stations, crest-stage gages, tidal crest-stage and tidal gaging stations show historical coverage. The data in this report represent that part of the National Water Information System (NWIS) data collected by the United States Geological Survey (USGS). Hydrologic conditions are also described for this water year, including streamflow, precipitation, reservoir conditions, and air temperatures.

  15. Water resources data, New Jersey, water year 2005. Volume 1 - surface-water data

    USGS Publications Warehouse

    White, B.T.; Hoppe, H.L.; Centinaro, G.L.; Dudek, J.F.; Painter, B.S.; Protz, A.R.; Reed, T.J.; Shvanda, J.C.; Watson, A.F.

    2006-01-01

    Water-resources data for the 2005 water year for New Jersey are presented in three volumes, and consists of records of stage, discharge, and water-quality of streams; stage and contents of lakes and reservoirs; and water levels and water-quality of ground water. Volume 1 contains discharge records for 103 gaging stations; tide summaries at 28 tidal gaging stations; stage and contents at 34 lakes and reservoirs; and diversions from 50 surface-water sources. Also included are stage and discharge for 116 crest-stage partial-record stations, stage-only at 33 tidal crest-stage gages, and discharge for 155 low-flow partial-record stations. Locations of these sites are shown in figures 8-11. Additional discharge measurements were made at 222 miscellaneous sites that are not part of the systematic data-collection program. Discontinued station tables for gaging stations, crest-stage gages, tidal crest-stage and tidal gaging stations show historical coverage. The data in this report represent that part of the National Water Information System (NWIS) data collected by the United States Geological Survey (USGS). Hydrologic conditions are also described for this water year, including stream-flow, precipitation, reservoir conditions, and air temperatures.

  16. Water resources data, New Jersey, water year 2004-volume 1. surface-water data

    USGS Publications Warehouse

    Centinaro, G.L.; White, B.T.; Hoppe, H.L.; Dudek, J.F.; Protz, A.R.; Reed, T.J.; Shvanda, J.C.; Watson, A.F.

    2005-01-01

    Water-resources data for the 2004 water year for New Jersey are presented in three volumes, and consists of records of stage, discharge, and water-quality of streams; stage and contents of lakes and reservoirs; and water levels and water-quality of ground water. Volume 1 contains discharge records for 105 gaging stations; tide summaries at 27 tidal gaging stations; stage and contents at 39 lakes and reservoirs; and diversions from 51 surface-water sources. Also included are stage and discharge for 108 crest-stage partial-record stations, stage-only at 34 tidal crest-stage gages, and discharge for 124 low-flow partial-record stations. Locations of these sites are shown in figures 8-11. Additional discharge measurements were made at 131 miscellaneous sites that are not part of the systematic data-collection program. Discontinued station tables for gaging stations, crest-stage gages, tidal crest-stage and tidal gaging stations show historical coverage. The data in this report represent that part of the National Water Information System (NWIS) data collected by the United States Geological Survey (USGS). Hydrologic conditions are also described for this water year, including stream-flow, precipitation, reservoir conditions, and air temperatures.

  17. Rebound of a coal tar creosote plume following partial source zone treatment with permanganate.

    PubMed

    Thomson, N R; Fraser, M J; Lamarche, C; Barker, J F; Forsey, S P

    2008-11-14

    The long-term management of dissolved plumes originating from a coal tar creosote source is a technical challenge. For some sites stabilization of the source may be the best practical solution to decrease the contaminant mass loading to the plume and associated off-site migration. At the bench-scale, the deposition of manganese oxides, a permanganate reaction byproduct, has been shown to cause pore plugging and the formation of a manganese oxide layer adjacent to the non-aqueous phase liquid creosote which reduces post-treatment mass transfer and hence mass loading from the source. The objective of this study was to investigate the potential of partial permanganate treatment to reduce the ability of a coal tar creosote source zone to generate a multi-component plume at the pilot-scale over both the short-term (weeks to months) and the long-term (years) at a site where there is >10 years of comprehensive synoptic plume baseline data available. A series of preliminary bench-scale experiments were conducted to support this pilot-scale investigation. The results from the bench-scale experiments indicated that if sufficient mass removal of the reactive compounds is achieved then the effective solubility, aqueous concentration and rate of mass removal of the more abundant non-reactive coal tar creosote compounds such as biphenyl and dibenzofuran can be increased. Manganese oxide formation and deposition caused an order-of-magnitude decrease in hydraulic conductivity. Approximately 125 kg of permanganate were delivered into the pilot-scale source zone over 35 days, and based on mass balance estimates <10% of the initial reactive coal tar creosote mass in the source zone was oxidized. Mass discharge estimated at a down-gradient fence line indicated >35% reduction for all monitored compounds except for biphenyl, dibenzofuran and fluoranthene 150 days after treatment, which is consistent with the bench-scale experimental results. Pre- and post-treatment soil core data indicated a highly variable and random spatial distribution of mass within the source zone and provided no insight into the mass removed of any of the monitored species. The down-gradient plume was monitored approximately 1, 2 and 4 years following treatment. The data collected at 1 and 2 years post-treatment showed a decrease in mass discharge (10 to 60%) and/or total plume mass (0 to 55%); however, by 4 years post-treatment there was a rebound in both mass discharge and total plume mass for all monitored compounds to pre-treatment values or higher. The variability of the data collected was too large to resolve subtle changes in plume morphology, particularly near the source zone, that would provide insight into the impact of the formation and deposition of manganese oxides that occurred during treatment on mass transfer and/or flow by-passing. Overall, the results from this pilot-scale investigation indicate that there was a significant but short-term (months) reduction of mass emanating from the source zone as a result of permanganate treatment but there was no long-term (years) impact on the ability of this coal tar creosote source zone to generate a multi-component plume.

  18. Stage-discharge relations and annual nitrogen and phosphorus load estimates for stream sites in the Elk River Basin, 2006–2008

    USGS Publications Warehouse

    Hoos, Anne B.; Williams, Shannon D.; Wolfe, William J.

    2016-11-22

    The U.S. Geological Survey, in cooperation with the Tennessee Department of Environment and Conservation (TDEC), measured continuous discharge at 4 water-quality monitoring sites and developed stage-discharge ratings for 10 additional water-quality monitoring sites in the Elk River Basin during 2006 through 2008. The discharge data were collected to support stream load assessments by TDEC. Annual nitrogen and phosphorus loads were estimated for the four sites where continuous daily discharge records were collected. Reported loads for the period 2006 through 2008 are not representative of long-term mean annual conditions at the sites in this study, however, because of severe drought conditions in the Elk River Basin during this period.

  19. The dynamic monitoring of warm-water discharge based on the airborne high-resolution thermal infrared remote sensing data

    NASA Astrophysics Data System (ADS)

    Shao, Honglan; Xie, Feng; Liu, Chengyu; Liu, Zhihui; Zhang, Changxing; Yang, Gui; Wang, Jianyu

    2016-04-01

    The cooling water discharged from the coastal plants flow into the sea continuously, whose temperature is higher than original sea surface temperature (SST). The fact will have non-negligible influence on the marine environment in and around where the plants site. Hence, it's significant to monitor the temporal and spatial variation of the warm-water discharge for the assessment of the effect of the plant on its surrounding marine environment. The paper describes an approach for the dynamic monitoring of the warm-water discharge of coastal plants based on the airborne high-resolution thermal infrared remote sensing technology. Firstly, the geometric correction was carried out for the thermal infrared remote sensing images acquired on the aircraft. Secondly, the atmospheric correction method was used to retrieve the sea surface temperature of the images. Thirdly, the temperature-rising districts caused by the warm-water discharge were extracted. Lastly, the temporal and spatial variations of the warm-water discharge were analyzed through the geographic information system (GIS) technology. The approach was applied to Qinshan nuclear power plant (NPP), in Zhejiang Province, China. In considering with the tide states, the diffusion, distribution and temperature-rising values of the warm-water discharged from the plant were calculated and analyzed, which are useful to the marine environment assessment.

  20. Discharge communication from inpatient care: an audit of written medical discharge summary procedure against the new National Health Service Standard for clinical handover.

    PubMed

    Reid, Daniel Brooks; Parsons, Shaun R; Gill, Stephen D; Hughes, Andrew J

    2015-04-01

    To audit written medical discharge summary procedure and practice against Standard Six (clinical handover) of the Australian National Safety and Quality Health Service Standards at a major regional Victorian health service. Department heads were invited to complete a questionnaire about departmental discharge summary practices. Twenty-seven (82%) department heads completed the questionnaire. Seven (26%) departments had a documented discharge summary procedure. Fourteen (52%) departments monitored discharge summary completion and 13 (48%) departments monitored the timeliness of completion. Seven (26%) departments informed the patient of the content of the discharge summary and six (22%) departments provided the patient with a copy. Seven (26%) departments provided training for staff members on how to complete discharge summaries. Completing discharge summaries was usually delegated to the medical intern. The introduction of the National Service Standards prompted an organisation-wide audit of discharge summary practices against the external criterion. There was substantial variation in the organisation's practices. The Standards and the current audit results highlight an opportunity for the organisation to enhance and standardise discharge summary practices and improve communication with general practice.

  1. Real-time radiative divertor feedback control development for the NSTX-U tokamak using a vacuum ultraviolet spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soukhanovskii, V. A., E-mail: vlad@llnl.gov; Kaita, R.; Stratton, B.

    2016-11-15

    A radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature T{sub e} estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPherson Modelmore » 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the Δn = 0, 1 line intensity ratios of carbon, nitrogen, or neon ion lines in the spectral range 300–1600 Å. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time T{sub e}-dependent signal within a characteristic divertor detachment equilibration time of ∼10–15 ms is expected.« less

  2. Real-time radiative divertor feedback control development for the NSTX-U tokamak using a vacuum ultraviolet spectrometer

    DOE PAGES

    Soukhanovskii, V. A.; Kaita, R.; Stratton, B.

    2016-08-04

    Here, a radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature T e estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPhersonmore » Model 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the Δn = 0, 1 line intensity ratios of carbon, nitrogen, or neon ion lines in the spectral range 300–1600 Å. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time T e-dependent signal within a characteristic divertor detachment equilibration time of ~10–15 ms is expected.« less

  3. X-ray tomography as a powerful method for zinc-air battery research

    NASA Astrophysics Data System (ADS)

    Franke-Lang, Robert; Arlt, Tobias; Manke, Ingo; Kowal, Julia

    2017-12-01

    X-ray tomography is used to investigate material redistribution and effects of electrochemical reactions in a zinc-air battery in-situ. For this, a special battery set-up is developed which meets tomographic and electrochemical requirements. The prepared batteries are discharged and some of them have partially been charged. To analyse the three-dimensional structure of the zinc and air electrode a tomographic measurement is made in charge and discharge condition without disassembling the battery. X-ray tomography gives the opportunity to detect and analyse three different effects within the cell operation: tracking the morphology and transformation of zinc and air electrode, monitoring electrolyte decomposition and movement, finding electrical misbehaviour by parasitic reactions. Therefore, it is possible to identify the loss of capacity and major problems of cyclability. The electrolyte strongly reacts with the pure zinc that leads to gassing and a loss of electrolyte. The loss prevents a charge carrier exchange between the anode and the cathode and reduces the theoretical capacity. One of the chemical reaction produces hydroxylated zinc, namely zincate. The most crucial problems with cyclability are affected by zincate movement into the catalyst layer. This assumption is confirmed by finding pure zinc areas within the catalyst layer.

  4. Compact lumped circuit model of discharges in DC accelerator using partial element equivalent circuit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banerjee, Srutarshi; Rajan, Rehim N.; Singh, Sandeep K.

    2014-07-01

    DC Accelerators undergoes different types of discharges during its operation. A model depicting the discharges has been simulated to study the different transient conditions. The paper presents a Physics based approach of developing a compact circuit model of the DC Accelerator using Partial Element Equivalent Circuit (PEEC) technique. The equivalent RLC model aids in analyzing the transient behavior of the system and predicting anomalies in the system. The electrical discharges and its properties prevailing in the accelerator can be evaluated by this equivalent model. A parallel coupled voltage multiplier structure is simulated in small scale using few stages of coronamore » guards and the theoretical and practical results are compared. The PEEC technique leads to a simple model for studying the fault conditions in accelerator systems. Compared to the Finite Element Techniques, this technique gives the circuital representation. The lumped components of the PEEC are used to obtain the input impedance and the result is also compared to that of the FEM technique for a frequency range of (0-200) MHz. (author)« less

  5. Characteristics of long-gap AC streamer discharges under low pressure conditions

    NASA Astrophysics Data System (ADS)

    Yang, Yaqi; Li, Weiguo; Xia, Yu; Yuan, Chuangye

    2017-10-01

    The generation and propagation of a streamer is a significant physical process of air gap discharge. Research on the mechanism of streamers under low-pressure conditions is helpful for understanding the process of long-gap discharge in a high-altitude area. This paper describes laboratory investigations of streamer discharge under alternating current (AC) voltage in a low pressure test platform for a 60 cm rod-plane gap at 30 kPa, and analyzes the characteristics of streamer generation and propagation. The results show that the partial streamer and breakdown streamer all occur in the positive half-cycle of AC voltage near the peak voltage at 30 kPa. The partial streamer could cause the distortion of current and voltage waveform, and it appears as the branching characteristic at the initial stage. With the extension of the streamer, the branching and tortuosity phenomena become gradually obvious, but the branching is suppressed when the streamer crosses the gap. The low-pressure condition has little influence on the tortuosity length and the tortuosity number of the streamer, but affect the diameter of streamer obviously.

  6. Insulation Coordination and Failure Mitigation Concerns for Roust Dc Electrical Power Systems (Preprint)

    DTIC Science & Technology

    2014-05-01

    vulnerable to failure is air. This could be a discharge through an air medium or along an air/surface interface. Achieving robustness in dc power...sputtering” arcs) are discharges that are most commonly located in series with the intended load; the electrical impedance of the load limits the...particularly those used at voltages > 1000 V, is detection and measurement of partial- discharge (PD) activity. The presence of PD in a component typically

  7. Internal Electrostatic Discharge Monitor - IESDM

    NASA Technical Reports Server (NTRS)

    Kim, Wousik; Goebel, Dan M.; Jun, Insoo; Garrett, Henry B.

    2011-01-01

    A document discusses an innovation designed to effectively monitor dielectric charging in spacecraft components to measure the potential for discharge in order to prevent damage from internal electrostatic discharge (IESD). High-energy electrons penetrate the structural materials and shielding of a spacecraft and then stop inside dielectrics and keep accumulating. Those deposited charges generate an electric field. If the electric field becomes higher than the breakdown threshold (approx. =2 x 10(exp 5) V/cm), discharge occurs. This monitor measures potentials as a function of dielectric depth. Differentiation of potential with respect to the depth yields electric field. Direct measurement of the depth profile of the potential in a dielectric makes real-time electronic field evaluation possible without simulations. The IESDM has been designed to emulate a multi-layer circuit board, to insert very thin metallic layers between the dielectric layers. The conductors serve as diagnostic monitoring locations to measure the deposited electron-charge and the charge dynamics. Measurement of the time-dependent potential of the metal layers provides information on the amount of charge deposited in the dielectrics and the movement of that charge with time (dynamics).

  8. Laser optogalvanic spectroscopy of molecules

    NASA Technical Reports Server (NTRS)

    Webster, C. R.; Rettner, C. T.

    1983-01-01

    In laser optogalvanic (LOG) spectroscopy, a tunable laser is used to probe the spectral characteristics of atomic or molecular species within an electrical discharge in a low pressure gas. Optogalvanic signals arise when the impedance of the discharge changes in response to the absorption of laser radiation. The technique may, therefore, be referred to as impedance spectroscopy. This change in impedance may be monitored as a change in the voltage across the discharge tube. LOG spectra are recorded by scanning the wavelength of a chopped CW dye laser while monitoring the discharge voltage with a lock-in amplifier. LOG signals are obtained if the laser wavelength matches a transition in a species present in the discharge (or flame), and if the absorption of energy in the laser beam alters the impedance of the discharge. Infrared LOG spectroscopy of molecules has been demonstrated and may prove to be the most productive application in the field of optogalvanic techniques.

  9. Rosiglitazone Suppresses In Vitro Seizures in Hippocampal Slice by Inhibiting Presynaptic Glutamate Release in a Model of Temporal Lobe Epilepsy.

    PubMed

    Wong, Shi-Bing; Cheng, Sin-Jhong; Hung, Wei-Chen; Lee, Wang-Tso; Min, Ming-Yuan

    2015-01-01

    Peroxisomal proliferator-activated receptor gamma (PPARγ) is a nuclear hormone receptor whose agonist, rosiglitazone has a neuroprotective effect to hippocampal neurons in pilocarpine-induced seizures. Hippocampal slice preparations treated in Mg2+ free medium can induce ictal and interictal-like epileptiform discharges, which is regarded as an in vitro model of N-methyl-D-aspartate (NMDA) receptor-mediated temporal lobe epilepsy (TLE). We applied rosiglitazone in hippocampal slices treated in Mg2+ free medium. The effects of rosiglitazone on hippocampal CA1-Schaffer collateral synaptic transmission were tested. We also examined the neuroprotective effect of rosiglitazone toward NMDA excitotoxicity on cultured hippocampal slices. Application of 10 μM rosiglitazone significantly suppressed amplitude and frequency of epileptiform discharges in CA1 neurons. Pretreatment with the PPARγ antagonist GW9662 did not block the effect of rosiglitazone on suppressing discharge frequency, but reverse the effect on suppressing discharge amplitude. Application of rosiglitazone suppressed synaptic transmission in the CA1-Schaffer collateral pathway. By miniature excitatory-potential synaptic current (mEPSC) analysis, rosiglitazone significantly suppressed presynaptic neurotransmitter release. This phenomenon can be reversed by pretreating PPARγ antagonist GW9662. Also, rosiglitazone protected cultured hippocampal slices from NMDA-induced excitotoxicity. The protective effect of 10 μM rosiglitazone was partially antagonized by concomitant high dose GW9662 treatment, indicating that this effect is partially mediated by PPARγ receptors. In conclusion, rosiglitazone suppressed NMDA receptor-mediated epileptiform discharges by inhibition of presynaptic neurotransmitter release. Rosiglitazone protected hippocampal slice from NMDA excitotoxicity partially by PPARγ activation. We suggest that rosiglitazone could be a potential agent to treat patients with TLE.

  10. Experiment of monitoring thermal discharge drained from nuclear plant through airborne infrared remote sensing

    NASA Astrophysics Data System (ADS)

    Wang, Difeng; Pan, Delu; Li, Ning

    2009-07-01

    The State Development and Planning Commission has approved nuclear power projects with the total capacity of 23,000 MW. The plants will be built in Zhejiang, Jiangsu, Guangdong, Shandong, Liaoning and Fujian Province before 2020. However, along with the nuclear power policy of accelerated development in our country, the quantity of nuclear plants and machine sets increases quickly. As a result the environment influence of thermal discharge will be a problem that can't be slid over. So evaluation of the environment influence and engineering simulation must be performed before station design and construction. Further more real-time monitoring of water temperature need to be arranged after fulfillment, reflecting variety of water temperature in time and provided to related managing department. Which will help to ensure the operation of nuclear plant would not result in excess environment breakage. At the end of 2007, an airborne thermal discharge monitoring experiment has been carried out by making use of MAMS, a marine multi-spectral scanner equipped on the China Marine Surveillance Force airplane. And experimental subject was sea area near Qin Shan nuclear plant. This paper introduces the related specification and function of MAMS instrument, and decrypts design and process of the airborne remote sensing experiment. Experiment showed that applying MAMS to monitoring thermal discharge is viable. The remote sensing on a base of thermal infrared monitoring technique told us that thermal discharge of Qin Shan nuclear plant was controlled in a small scope, never breaching national water quality standard.

  11. Pulsed electrothermal thruster

    NASA Technical Reports Server (NTRS)

    Burton, Rodney L. (Inventor); Goldstein, Yeshayahu S. A. (Inventor); Tidman, Derek A. (Inventor); Winsor, Niels K. (Inventor)

    1989-01-01

    A plasma electrothermal thruster includes a capillary passage in which a plasma discharge is formed and directed out of an open end of the passage into a supersonic nozzle. Liquid supplied to the capillary passage becomes partially atomized to cool a confining surface of the passage. The plasma discharge is formed as the atomized liquid flows out of the open end into a supersonic equilibrium nozzle. The discharge can have a duration greater than the two way travel time of acoustic energy in the capillary to cause the plasma to flow continuously through the nozzle during the time of the discharge pulse.

  12. Feasibility of early discharge after implantable cardioverter-defibrillator procedures.

    PubMed

    Choudhuri, Indrajit; Desai, Dipan; Walburg, Jon; August, Phyllis; Keller, Seth I; Suri, Ranjit

    2012-10-01

    Registry data demonstrate considerably low complication rates after implantable cardioverter-defibrillator (ICD) procedures for primary prevention of sudden death. Yet standard of care includes postimplant overnight in-hospital observation that may levy substantial unnecessary financial burden on health care systems. In appropriate patients, discharge soon after implant could translate into significant cost savings, if such practice does not result in complications. We applied a simple clinical algorithm to assess feasibility of discharge on the same day of ICD implantation in patients at low risk for procedural complications. We prospectively randomized primary prevention ICD candidates at low risk for complications (not pacing-dependent or requiring bridging heparin anticoagulation) to next-day discharge with overnight in-hospital observation, or same-day discharge with remote monitoring for 24 hours after ICD implant. Implants were performed via cephalic vein access, and randomization occurred after 4-hours clinical observation and device interrogation. All patients were followed for a minimum of 6 weeks to assess acute procedural complications. 71 patients comprised the study cohort (mean age 62, 79% male) after 3 were excluded. The most common indication for ICD implant was ischemic cardiomyopathy with ejection fraction ≤35%. Device data obtained through 24-hour remote monitoring was comparable to 4-hour postimplant parameters in same-day discharge patients. No acute complications occurred in same-day discharge patients; 1 next-day discharge patient developed pneumothorax. ICD implantation with same-day discharge is reasonable in patients at low risk for complications. Remote monitoring can be useful in indicating lead-parameter stability during the immediate postoperative period. © 2012 Wiley Periodicals, Inc.

  13. Influence of N2 partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N2 vacuum arc discharge

    NASA Astrophysics Data System (ADS)

    Naddaf, M.; Abdallah, B.; Ahmad, M.; A-Kharroub, M.

    2016-08-01

    The influence of N2 partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N2 partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N2 partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N2 partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N2 partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N2 partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N2 partial pressure.

  14. Factors controlling stream water nitrate and phosphor loads during precipitation events

    NASA Astrophysics Data System (ADS)

    Rozemeijer, J. C.; van der Velde, Y.; van Geer, F. G.; de Rooij, G. H.; Broers, H. P.; Bierkens, M. F. P.

    2009-04-01

    Pollution of surface waters in densely populated areas with intensive land use is a serious threat to their ecological, industrial and recreational utilization. European and national manure policies and several regional and local pilot projects aim at reducing pollution loads to surface waters. For the evaluation of measures, water authorities and environmental research institutes are putting a lot of effort into monitoring surface water quality. Fro regional surface water quality monitoring, the measurement locations are usually situated in the downstream part of the catchment to represent a larger area. The monitoring frequency is usually low (e.g. monthly), due to the high costs for sampling and analysis. As a consequence, human induced trends in nutrient loads and concentrations in these monitoring data are often concealed by the large variability of surface water quality caused by meteorological variations. Because natural surface water quality variability is poorly understood, large uncertainties occur in the estimates of (trends in) nutrient loads or average concentrations. This study aims at uncertainty reduction in the estimates of mean concentrations and loads of N and P from regional monitoring data. For this purpose, we related continuous N and P records of stream water to variations in precipitation, discharge, groundwater level and tube drain discharge. A specially designed multi scale experimental setup was installed in an agricultural lowland catchment in The Netherlands. At the catchment outlet, continuous measurements of water quality and discharge were performed from July 2007-January 2009. At an experimental field within the catchment continuous measurements of precipitation, groundwater levels and tube drain discharges were collected. 20 significant rainfall events with a variety of antecedent conditions, durations and intensities were selected for analysis. Singular and multiple regression analysis was used to identify relations between the continuous N and P records and characteristics of the dynamics of discharge, precipitation, groundwater level and tube drain discharge. From this study, we conclude that generally available and easy to measure explanatory data (such as continuous records of discharge, precipitation and groundwater level) can reduce uncertainty in estimations of N and P loads and mean concentrations. However, for capturing the observed short load pulses of P, continuous or discharge proportional sampling is needed.

  15. Water resources data for New Mexico, water year 1975

    USGS Publications Warehouse

    ,

    1976-01-01

    Water resources data for the 1975 water year for New Mexico consist of records of discharge and water quality of streams; stage, contents and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. This report contains discharge records for 201 gaging stations; stage and contents far 23 lakes and reservoirs; water quality for 62 gaging stations, 77 partial-record flow stations, 1 reservoir, 47 springs and 197 wells; and water levels for 93 observation wells. Also included are 162 crest-stage partial-record stations and 2 low-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic da,ta collection program, and are pu,blis"Q,ed as miscellaneous measurements. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in New Mexico.

  16. The role of passive sampling in monitoring the environmental impacts of produced water discharges from the Norwegian oil and gas industry.

    PubMed

    Hale, Sarah E; Oen, Amy M P; Cornelissen, Gerard; Jonker, Michiel T O; Waarum, Ivar-Kristian; Eek, Espen

    2016-10-15

    Stringent and periodic iteration of regulations related to the monitoring of chemical releases from the offshore oil and gas industry requires the use of ever changing, rapidly developing and technologically advancing techniques. Passive samplers play an important role in water column monitoring of produced water (PW) discharge to seawater under Norwegian regulation, where they are used to; i) measure aqueous concentrations of pollutants, ii) quantify the exposure of caged organisms and investigate PW dispersal, and iii) validate dispersal models. This article summarises current Norwegian water column monitoring practice and identifies research and methodological gaps for the use of passive samplers in monitoring. The main gaps are; i) the range of passive samplers used should be extended, ii) differences observed in absolute concentrations accumulated by passive samplers and organisms should be understood, and iii) the link between PW discharge concentrations and observed acute and sub-lethal ecotoxicological end points in organisms should be investigated. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Monitoring of tritium

    DOEpatents

    Corbett, James A.; Meacham, Sterling A.

    1981-01-01

    The fluid from a breeder nuclear reactor, which may be the sodium cooling fluid or the helium reactor-cover-gas, or the helium coolant of a gas-cooled reactor passes over the portion of the enclosure of a gaseous discharge device which is permeable to hydrogen and its isotopes. The tritium diffused into the discharge device is radioactive producing beta rays which ionize the gas (argon) in the discharge device. The tritium is monitored by measuring the ionization current produced when the sodium phase and the gas phase of the hydrogen isotopes within the enclosure are in equilibrium.

  18. 40 CFR 132.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Species Act. Existing Great Lakes discharger is any building, structure, facility, or installation from... discharger is any building, structure, facility, or installation from which there is or may be a “discharge... monitoring of the contaminant. Quantitative structure activity relationship (QSAR) or structure activity...

  19. Weight loss and jaundice in healthy term newborns in partial and full rooming-in.

    PubMed

    Zuppa, Antonio Alberto; Sindico, Paola; Antichi, Eleonora; Carducci, Chiara; Alighieri, Giovanni; Cardiello, Valentina; Cota, Francesco; Romagnoli, Costantino

    2009-09-01

    An inadequate start of breastfeeding has been associated with reduced caloric intake, excessive weight loss and high serum bilirubin levels in the first days of life. The rooming-in has been proposed as an optimal model for the promotion of breastfeeding. The aim of this study was to compare two different feeding models (partial and full rooming-in) to evaluate differences as regard to weight loss, hyperbilirubinemia and prevalence of exclusive breastfeeding at discharge. A total of 903 healthy term newborns have been evaluated; all the newborns were adequate for gestational age, with birth weight > or = 2800 g and gestational age > or = 37 weeks. The maximum weight loss (mean +/- SD), expressed as percent of birth weight, was not different in the two models (partial vs. full rooming-in 5.8% +/- 1.7%vs. 6% +/- 1.7%). A weight loss > or = 10% occurred in less than 1% in both groups. There were no statistical differences neither as mean of total serum bilirubin (partial vs. full rooming-in 10.5 +/- 3.3 vs. 10.1 +/- 2.9 mg/dl), nor as prevalence of hyperbilirubinemia (total serum bilirubin > or = 12 mg/dl). The prevalence of severe hyperbilirubinemia (total serum bilirubin > or = 18 mg/dl) and the use of phototherapy were not statistically different. Maximum weight loss was similar in the two models, even dividing by total serum bilirubin levels. At the discharge, exclusively breastfed newborns were 81% in full rooming-in and 42.9% in partial rooming-in. In conclusion, our results allow considering our assistance models similar as regards to severe hyperbilirubinemia and pathological weight loss in term healthy newborns even if full rooming-in is associated with higher prevalence of exclusive breastfeeding at the discharge.

  20. Heterogeneous hyporheic zone dechlorination of a TCE groundwater plume discharging to an urban river reach.

    PubMed

    Freitas, Juliana G; Rivett, Michael O; Roche, Rachel S; Durrant Neé Cleverly, Megan; Walker, Caroline; Tellam, John H

    2015-02-01

    The typically elevated natural attenuation capacity of riverbed-hyporheic zones is expected to decrease chlorinated hydrocarbon (CHC) groundwater plume discharges to river receptors through dechlorination reactions. The aim of this study was to assess physico-chemical processes controlling field-scale variation in riverbed-hyporheic zone dechlorination of a TCE groundwater plume discharge to an urban river reach. The 50-m long pool-riffle-glide reach of the River Tame in Birmingham (UK) studied is a heterogeneous high energy river environment. The shallow riverbed was instrumented with a detailed network of multilevel samplers. Freeze coring revealed a geologically heterogeneous and poorly sorted riverbed. A chlorine number reduction approach provided a quantitative indicator of CHC dechlorination. Three sub-reaches of contrasting behaviour were identified. Greatest dechlorination occurred in the riffle sub-reach that was characterised by hyporheic zone flows, moderate sulphate concentrations and pH, anaerobic conditions, low iron, but elevated manganese concentrations with evidence of sulphate reduction. Transient hyporheic zone flows allowing input to varying riverbed depths of organic matter are anticipated to be a key control. The glide sub-reach displayed negligible dechlorination attributed to the predominant groundwater baseflow discharge condition, absence of hyporheic zone, transition to more oxic conditions and elevated sulphate concentrations expected to locally inhibit dechlorination. The tail-of-pool-riffle sub-reach exhibited patchy dechlorination that was attributed to sub-reach complexities including significant flow bypass of a low permeability, high organic matter, silty unit of high dechlorination potential. A process-based conceptual model of reach-scale dechlorination variability was developed. Key findings of practitioner relevance were: riverbed-hyporheic zone CHC dechlorination may provide only a partial, somewhat patchy barrier to CHC groundwater plume discharges to a surface water receptor; and, monitoring requirements to assess the variability in CHC attenuation within a reach are expected to be onerous. Further research on transient hyporheic zone dechlorination is recommended. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Method and means for measuring acoustic emissions

    DOEpatents

    Renken, Jr., Claus J.

    1976-01-06

    The detection of acoustic emissions emanating from an object is achieved with a capacitive transducer coupled to the object. The capacitive transducer is charged and then allowed to discharge with the rate of discharge being monitored. Oscillations in the rate of discharge about the normally exponential discharge curve for the capacitive transducer indicate the presence of acoustic emissions.

  2. Water Resources Data for California, Water Year 1985. Volume 2. Pacific Slope Basins from Arroyo Grande to Oregon State Line except Central Valley

    USGS Publications Warehouse

    Anderson, S.; Markham, K.L.; Trujillo, L.F.; Shelton, W.F.; Grillo, D.A.

    1987-01-01

    Water resources data for the 1985 water year for California consists of records of stage, discharge, and water quality of streams; and stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 2 contains discharge records for 133 gaging stations; stage and contents for 9 lakes and reservoirs; and water quality for 34 stations. Also included are 3 low-flow partial-record stations and 1 water-quality partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  3. Study of cross-shaped ultrasonic array sensor applied to partial discharge location in transformer oil.

    PubMed

    Li, Jisheng; Xin, Xiaohu; Luo, Yongfen; Ji, Haiying; Li, Yanming; Deng, Junbo

    2013-11-01

    A conformal combined sensor is designed and it is used in Partial Discharge (PD) location experiments in transformer oil. The sensor includes a cross-shaped ultrasonic phased array of 13 elements and an ultra-high-frequency (UHF) electromagnetic rectangle array of 2 × 2 elements. Virtual expansion with high order cumulants, the ultrasonic array can achieve the effect of array with 61 elements. This greatly improves the aperture and direction sharpness of original array and reduces the cost of follow-up hardware. With the cross-shaped ultrasonic array, the results of PD location experiments are precise and the maximum error of the direction of arrival (DOA) is less than 5°.

  4. Water resources data for California water year 1994. Volume 1. Southern Great Basin from Mexican border to Mono Lake basin, and Pacific Slope basins from Tijuana River to Santa Maria river. Water-data report (Annual), 1 October 1993-30 September 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayes, P.D.; Agajanian, J.A.; Rockwell, G.L.

    1995-03-01

    Water resources data for the 1994 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 143 streamflow-gaging stations, 15 crest-stage partial-record streamflow stations; (2) stage and contents records for 20 lakes and reservoirs; (3) water quality records for 19 streamflow-gaging stations and 2 partial-record stations; and (4) precipitation records for 8 stations.

  5. Monitoring as a partially observable decision problem

    Treesearch

    Paul L. Fackler; Robert G. Haight

    2014-01-01

    Monitoring is an important and costly activity in resource man-agement problems such as containing invasive species, protectingendangered species, preventing soil erosion, and regulating con-tracts for environmental services. Recent studies have viewedoptimal monitoring as a Partially Observable Markov Decision Pro-cess (POMDP), which provides a framework for...

  6. Minimum average 7-day, 10-year flows in the Hudson River basin, New York, with release-flow data on Rondout and Ashokan reservoirs

    USGS Publications Warehouse

    Archer, Roger J.

    1978-01-01

    Minimum average 7-day, 10-year flow at 67 gaging stations and 173 partial-record stations in the Hudson River basin are given in tabular form. Variation of the 7-day, 10-year low flow from point to point in selected reaches, and the corresponding times of travel, are shown graphically for Wawayanda Creek, Wallkill River, Woodbury-Moodna Creek, and the Fishkill Creek basins. The 7-day, 10-year low flow for the Saw Kill basin, and estimates of the 7-day, 10-year low flow of the Roeliff Jansen Kill at Ancram and of Birch Creek at Pine Hill, are given. Summaries of discharge from Rondout and Ashokan Reservoirs, in Ulster County, are also included. Minimum average 7-day, 10-year flow for gaging stations with 10 years or more of record were determined by log-Pearson Type III computation; those for partial-record stations were developed by correlation of discharge measurements made at the partial-record stations with discharge data from appropriate long-term gaging stations. The variation in low flows from point to point within the selected subbasins were estimated from available data and regional regression formula. Time of travel at these flows in the four subbasins was estimated from available data and Boning's equations.

  7. Classification of Partial Discharge Measured under Different Levels of Noise Contamination.

    PubMed

    Jee Keen Raymond, Wong; Illias, Hazlee Azil; Abu Bakar, Ab Halim

    2017-01-01

    Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD) and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE) cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA) features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN), Adaptive Neuro-Fuzzy Inference System (ANFIS) and Support Vector Machine (SVM). It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination.

  8. Discharging a DC bus capacitor of an electrical converter system

    DOEpatents

    Kajouke, Lateef A; Perisic, Milun; Ransom, Ray M

    2014-10-14

    A system and method of discharging a bus capacitor of a bidirectional matrix converter of a vehicle are presented here. The method begins by electrically shorting the AC interface of the converter after an AC energy source is disconnected from the AC interface. The method continues by arranging a plurality of switching elements of a second energy conversion module into a discharge configuration to establish an electrical current path from a first terminal of an isolation module, through an inductive element, and to a second terminal of the isolation module. The method also modulates a plurality of switching elements of a first energy conversion module, while maintaining the discharge configuration of the second energy conversion module, to at least partially discharge a DC bus capacitor.

  9. Impacts of blending on dilution of negatively buoyant brine discharge in a shallow tidal sea.

    PubMed

    Kämpf, Jochen

    2009-07-01

    A fine-resolution three-dimensional hydrodynamic model is applied to study the dilution of desalination brine discharged into a tidal sea. Based on given inflow rate and salinity excess of discharge brine, this study explores variations in mid-field dilutions when other low-salinity wastewater is added to the discharge. Findings reveal that this blending leads to a decrease in dilution in the mixing zone and therefore to higher levels of pollutants in this zone, while, on the other hand, the mixing zone occupies a smaller area. The reason is that the discharge of brine creates a density-driven flow that operates to partially remove effluent from the discharge location. This removal is less efficient for the decrease in density excess of the discharge. Hence, in an ambient sea of moderate mixing, blending can be expected to increase the risk of marine pollution in the mixing zone.

  10. 26 CFR 1.662(a)-4 - Amounts used in discharge of a legal obligation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the terms of a will or trust instrument, is used in full or partial discharge or satisfaction of a... support his minor child if under local law property or income from property owned by the child cannot be... law a mother may use the resources of a child for the child's support in lieu of supporting him...

  11. Effectiveness of home- and community-based rehabilitation in a large cohort of patients disabled by cerebrovascular accident: evidence of a dose-response relationship.

    PubMed

    Altman, Irwin M; Swick, Shannon; Malec, James F

    2013-09-01

    To (1) assess the effectiveness of home- and community-based rehabilitation (HCBR) in a large cohort of individuals with disabilities secondary to cerebrovascular accident (CVA); and (2) evaluate the responsiveness to treatment of the Mayo-Portland Adaptability Inventory (MPAI-4) to changes resulting from HCBR in this patient group. Retrospective analysis of program evaluation data for treatment completers and noncompleters. HCBR conducted in 7 geographically distinct U.S. cities. Individuals with CVA (n=738) who completed the prescribed course of rehabilitation (completed course of treatment [CCT]) compared with 150 individuals who were precipitously discharged (PD) before program completion. HCBR delivered by certified professional staff on an individualized basis. Mayo-Portland Adaptability Inventory (MPAI-4) completed by professional consensus on admission and at discharge. With the use of analysis of covariance, MPAI-4 total scores at discharge for CCT participants were compared with those of PD participants, with admission MPAI-4, age, length of stay, and time since event as covariates. CCT participants showed greater improvement than PD participants (F=99.48, P<.001) with a moderate effect size (partial η(2)=.10). Group differences and effect sizes were similar for the 3 index scores: Ability (F=75.96, P<.001; partial η(2)=.08), Adjustment (F=99.67, P<.001; partial η(2)=.10), and Participation (F=69.15, P<.001; partial η(2)=.07). Individuals in the CCT group who received the entire planned course of HCBR showed greater improvement on all MPAI-4 indexes than those in the PD group who were discharged before completing the prescribed program. This dose-response relationship provides evidence of a causal relationship between treatment and outcome. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. Quantitative evaluation of intensive remedial action using long-term monitoring and tracer data at a DNAPL contaminated site, Wonju, Korea

    NASA Astrophysics Data System (ADS)

    Lee, S. S.; Kim, H. J.; Kim, M. O.; Lee, K.; Lee, K. K.

    2016-12-01

    A study finding evidence of remediation represented on monitoring data before and after in site intensive remedial action was performed with various quantitative evaluation methods such as mass discharge analysis, tracer data, statistical trend analysis, and analytical solutions at DNAPL contaminated site, Wonju, Korea. Remediation technologies such as soil vapor extraction, soil flushing, biostimulation, and pump-and-treat have been applied to eliminate the contaminant sources of trichloroethylene (TCE) and to prevent the migration of TCE plume from remediation target zones. Prior to the remediation action, the concentration and mass discharges of TCE at all transects were affected by seasonal recharge variation and residual DNAPLs sources. After the remediation, the effect of remediation took place clearly at the main source zone and industrial complex. By tracing a time-series of plume evolution, a greater variation in the TCE concentrations was detected at the plumes near the source zones compared to the relatively stable plumes in the downstream. The removal amount of the residual source mass during the intensive remedial action was estimated to evaluate the efficiency of the intensive remedial action using analytical solution. From results of quantitative evaluation using analytical solution, it is assessed that the intensive remedial action had effectively performed with removal efficiency of 70% for the residual source mass during the remediation period. Analytical solution which can consider and quantify the impacts of partial mass reduction have been proven to be useful tools for quantifying unknown contaminant source mass and verifying dissolved concentration at the DNAPL contaminated site and evaluating the efficiency of remediation using long-term monitoring data. Acknowledgement : This subject was supported by the Korea Ministry of Environment under "GAIA project (173-092-009) and (201400540010)", R&D Project on Enviornmental Management of Geologic CO2 storage" from the KEITI (Project number:2014001810003).

  13. Direct writing of fiber optic components in photonic crystal fibers and other specialty fibers

    NASA Astrophysics Data System (ADS)

    Fernandes, Luis Andre; Sezerman, Omur; Best, Garland; Ng, Mi Li; Kane, Saidou

    2016-04-01

    Femtosecond direct laser writing has recently shown great potential for the fabrication of complex integrated devices in the cladding of optical fibers. Such devices have the advantage of requiring no bulk optical components and no breaks in the fiber path, thus reducing the need for complicated alignment, eliminating contamination, and increasing stability. This technology has already found applications using combinations of Bragg gratings, interferometers, and couplers for the fabrication of optical filters, sensors, and power monitors. The femtosecond laser writing method produces a local modification of refractive index through non-linear absorption of the ultrafast laser pulses inside the dielectric material of both the core and cladding of the fiber. However, fiber geometries that incorporate air or hollow structures, such as photonic crystal fibers (PCFs), still present a challenge since the index modification regions created by the writing process cannot be generated in the hollow regions of the fiber. In this work, the femtosecond laser method is used together with a pre-modification method that consists of partially collapsing the hollow holes using an electrical arc discharge. The partial collapse of the photonic band gap structure provides a path for femtosecond laser written waveguides to couple light from the core to the edge of the fiber for in-line power monitoring. This novel approach is expected to have applications in other specialty fibers such as suspended core fibers and can open the way for the integration of complex devices and facilitate miniaturization of optical circuits to take advantage of the particular characteristics of the PCFs.

  14. Assessing the effects of non-point source pollution on American Samoa's coral reef communities.

    PubMed

    Houk, Peter; Didonato, Guy; Iguel, John; Van Woesik, Robert

    2005-08-01

    Surveys were completed on Tutuila Island, American Samoa, to characterize reef development and assess the impacts of non-point source pollution on adjacent coral reefs at six sites. Multivariate analyses of benthic and coral community data found similar modern reef development at three locations; Aoa, Alofau, and Leone. These sites are situated in isolated bays with gentle sloping foundations. Aoa reefs had the highest estimates of crustose coralline algae cover and coral species richness, while Leone and Alofau showed high abundances of macroalgae and Porites corals. Aoa has the largest reef flat between watershed discharge and the reef slope, and the lowest human population density. Masefau and Fagaalu have a different geomorphology consisting of cemented staghorn coral fragments and steep slopes, however, benthic and coral communities were not similar. Benthic data suggest Fagaalu is heavily impacted compared with all other sites. Reef communities were assessed as bio-criteria indicators for waterbody health, using the EPA aquatic life use support designations of (1) fully supportive, (2) partially supportive, and (3) non-supportive for aquatic life. All sites resulted in a partially supportive ranking except Fagaalu, which was non-supportive. The results of this rapid assessment based upon relative benthic community measures are less desirable than long-term dataset analyses from monitoring programs, however it fills an important role for regulatory agencies required to report annual waterbody assessments. Future monitoring sites should be established to increase the number of replicates within each geological and physical setting to allow for meaningful comparisons along a gradient of hypothesized pollution levels.

  15. Lithium battery discharge tests

    NASA Technical Reports Server (NTRS)

    Johnson, C. J.

    1980-01-01

    The long term discharge of a variety of lithium cells was characterized and the susceptibility of the cells to chemical variation during the slow discharge was tested. A shunt resistor was set across the terminals to monitor the voltage as a function of time. Failures were identified by premature voltage drops.

  16. TRI and DMR Comparison Dashboard | ECHO | US EPA

    EPA Pesticide Factsheets

    The dashboard provides a comparison of wastewater discharge data reported on Discharge Monitoring Reports (DMRs) under the Clean Water Act (CWA) National Pollutant Discharge Elimination System (NPDES) permit program and water releases reported under the Toxics Release Inventory (TRI) at a national, regional, or state level.

  17. Results from the Big Spring basin water quality monitoring and demonstration projects, Iowa, USA

    USGS Publications Warehouse

    Rowden, R.D.; Liu, H.; Libra, R.D.

    2001-01-01

    Agricultural practices, hydrology, and water quality of the 267-km2 Big Spring groundwater drainage basin in Clayton County, Iowa, have been monitored since 1981. Land use is agricultural; nitrate-nitrogen (-N) and herbicides are the resulting contaminants in groundwater and surface water. Ordovician Galena Group carbonate rocks comprise the main aquifer in the basin. Recharge to this karstic aquifer is by infiltration, augmented by sinkhole-captured runoff. Groundwater is discharged at Big Spring, where quantity and quality of the discharge are monitored. Monitoring has shown a threefold increase in groundwater nitrate-N concentrations from the 1960s to the early 1980s. The nitrate-N discharged from the basin typically is equivalent to over one-third of the nitrogen fertilizer applied, with larger losses during wetter years. Atrazine is present in groundwater all year; however, contaminant concentrations in the groundwater respond directly to recharge events, and unique chemical signatures of infiltration versus runoff recharge are detectable in the discharge from Big Spring. Education and demonstration efforts have reduced nitrogen fertilizer application rates by one-third since 1981. Relating declines in nitrate and pesticide concentrations to inputs of nitrogen fertilizer and pesticides at Big Spring is problematic. Annual recharge has varied five-fold during monitoring, overshadowing any water-quality improvements resulting from incrementally decreased inputs. ?? Springer-Verlag 2001.

  18. The efficacy and resource utilization of remifentanil and fentanyl in fast-track coronary artery bypass graft surgery: a prospective randomized, double-blinded controlled, multi-center trial.

    PubMed

    Cheng, D C; Newman, M F; Duke, P; Wong, D T; Finegan, B; Howie, M; Fitch, J; Bowdle, T A; Hogue, C; Hillel, Z; Pierce, E; Bukenya, D

    2001-05-01

    We compared (a) the perioperative complications; (b) times to eligibility for, and actual time of the following: extubation, less intense monitoring, intensive care unit (ICU), and hospital discharge; and (c) resource utilization of nursing ratio for patients receiving either a typical fentanyl/isoflurane/propofol regimen or a remifentanil/isoflurane/propofol regimen for fast-track cardiac anesthesia in 304 adults by using a prospective randomized, double-blinded, double-dummy trial. There were no differences in demographic data, or perioperative mortality and morbidity between the two study groups. The mini-mental status examination at postoperative Days 1 to 3 were similar between the two groups. The eligible and actual times for extubation, less intense monitoring, ICU discharge, and hospital discharge were not significantly different. Further analyses revealed no differences in times for extubation and resource utilization after stratification by preoperative risk scores, age, and country. The nurse/patient ratio was similar between the remifentanil/isoflurane/propofol and fentanyl/isoflu-rane/propofol groups during the initial ICU phase and less intense monitoring phase. Increasing preoperative risk scores and older age (>70 yr) were associated with longer times until extubation (eligible), ICU discharge (eligible and actual), and hospital discharge (eligible and actual). Times until extubation (eligible and actual) and less intense monitoring (eligible) were significantly shorter in Canadian patients than United States' patients. However, there was no difference in hospital length of stay in Canadian and United States' patients. We conclude that both anesthesia techniques permit early and similar times until tracheal extubation, less intense monitoring, ICU and hospital discharge, and reduced resource utilization after coronary artery bypass graft surgery. An ultra-short opioid technique was compared with a standard fast-track small-dose opioid technique in coronary artery bypass graft patients in a prospective randomized, double-blinded controlled study. The postoperative recovery and resource utilization, including stratification of preoperative risk score, age, and country, were analyzed.

  19. A simple kinetic model of a Ne-H2 Penning-plasma laser

    NASA Astrophysics Data System (ADS)

    Petrov, G. M.; Stefanova, M. S.; Pramatarov, P. M.

    1995-09-01

    A simple kinetic model of the Ne-H2 Penning-Plasma Laser (PPL) (NeI 585.3 nm) is proposed. The negative glow of a hollow cathode discharge at intermediate pressures is considered as the active medium. The balance equations for the upper and lower laser levels, electrons, ions and electron energy are solved. The dependences of the laser gain on the discharge conditions (Ne and H2 partial pressures, discharge current) are calculated and measured. The calculated values are in a good agreement with the experimental data.

  20. Outcomes of low-weight patients with avoidant/restrictive food intake disorder and anorexia nervosa at long-term follow-up after treatment in a partial hospitalization program for eating disorders.

    PubMed

    Bryson, Amanda E; Scipioni, Anna M; Essayli, Jamal H; Mahoney, Johnna R; Ornstein, Rollyn M

    2018-05-01

    To assess long-term outcomes of patients with avoidant/restrictive food intake disorder (ARFID) treated in a partial hospitalization program (PHP) for eating disorders (ED). A cross-sectional study comparing patients with ARFID to those with anorexia nervosa (AN) who had been discharged from a PHP for at least 12 months was performed. Percent median body mass index (%MBMI), scores on the Children's Eating Attitudes Test (ChEAT), and treatment utilization were assessed, with intake and discharge data collected via retrospective chart review. Of the 137 eligible patients, 62 (45.3%) consented to follow-up data collection. Patients with ARFID and AN exhibited similar increases in %MBMI from intake to discharge and reported low scores on the ChEAT by discharge. Patients with ARFID and AN maintained good weight outcomes and low ChEAT scores at follow-up. Most participants were still receiving outpatient treatment from a variety of providers, although fewer with ARFID than AN continued to receive services from our multidisciplinary ED clinic. Patients with ARFID and AN exhibit similar improvements in %MBMI when treated in the same PHP and appear to maintain treatment gains at long-term follow-up. Additionally, most patients continue to utilize outpatient services after being discharged from a PHP. © 2018 Wiley Periodicals, Inc.

  1. Development of a real time monitor and multivariate method for long term diagnostics of atmospheric pressure dielectric barrier discharges: application to He, He/N2, and He/O2 discharges.

    PubMed

    O'Connor, N; Milosavljević, V; Daniels, S

    2011-08-01

    In this paper we present the development and application of a real time atmospheric pressure discharge monitoring diagnostic. The software based diagnostic is designed to extract latent electrical and optical information associated with the operation of an atmospheric pressure dielectric barrier discharge (APDBD) over long time scales. Given that little is known about long term temporal effects in such discharges, the diagnostic methodology is applied to the monitoring of an APDBD in helium and helium with both 0.1% nitrogen and 0.1% oxygen gas admixtures over periods of tens of minutes. Given the large datasets associated with the experiments, it is shown that this process is much expedited through the novel application of multivariate correlations between the electrical and optical parameters of the corresponding chemistries which, in turn, facilitates comparisons between each individual chemistry also. The results of these studies show that the electrical and optical parameters of the discharge in helium and upon the addition of gas admixtures evolve over time scales far longer than the gas residence time and have been compared to current modelling works. It is envisaged that the diagnostic together with the application of multivariate correlations will be applied to rapid system identification and prototyping in both experimental and industrial APDBD systems in the future.

  2. Feasibility and Acceptability of Utilizing a Smartphone Based Application to Monitor Outpatient Discharge Instruction Compliance in Cardiac Disease Patients around Discharge from Hospitalization

    PubMed Central

    Layton, Aimee M.; Whitworth, James; Peacock, James; Bartels, Matthew N.; Jellen, Patricia A.; Thomashow, Byron M.

    2014-01-01

    The purpose of this study was to determine the feasibility and acceptability of utilizing a smartphone based application to monitor compliance in patients with cardiac disease around discharge. For 60 days after discharge, patients' medication compliance, physical activity, follow-up care, symptoms, and reading of education material were monitored daily with the application. 16 patients were enrolled in the study (12 males, 4 females, age 55 ± 18 years) during their hospital stay. Five participants were rehospitalized during the study and did not use the application once discharged. Seven participants completed 1–30 days and four patients completed >31 days. For those 11 patients, medication reminders were utilized 37% (1–30-day group) and 53% (>31-day group) of the time, education material was read 44% (1–30) and 53% (>31) of the time, and physical activity was reported 25% (1–30) and 42% (>31) of the time. Findings demonstrated that patients with stable health utilized the application, even if only minimally. Patients with decreased breath sounds by physical exam and who reported their health as fair to poor on the day of discharge were less likely to utilize the application. Acceptability of the application to report health status varied among the stable patients. PMID:25574165

  3. Model-based screening for critical wet-weather discharges related to micropollutants from urban areas.

    PubMed

    Mutzner, Lena; Staufer, Philipp; Ort, Christoph

    2016-11-01

    Wet-weather discharges contribute to anthropogenic micropollutant loads entering the aquatic environment. Thousands of wet-weather discharges exist in Swiss sewer systems, and we do not have the capacity to monitor them all. We consequently propose a model-based approach designed to identify critical discharge points in order to support effective monitoring. We applied a dynamic substance flow model to four substances representing different entry routes: indoor (Triclosan, Mecoprop, Copper) as well as rainfall-mobilized (Glyphosate, Mecoprop, Copper) inputs. The accumulation on different urban land-use surfaces in dry weather and subsequent substance-specific wash-off is taken into account. For evaluation, we use a conservative screening approach to detect critical discharge points. This approach considers only local dilution generated onsite from natural, unpolluted areas, i.e. excluding upstream dilution. Despite our conservative assumptions, we find that the environmental quality standards for Glyphosate and Mecoprop are not exceeded during any 10-min time interval over a representative one-year simulation period for all 2500 Swiss municipalities. In contrast, the environmental quality standard is exceeded during at least 20% of the discharge time at 83% of all modelled discharge points for Copper and at 71% for Triclosan. For Copper, this corresponds to a total median duration of approximately 19 days per year. For Triclosan, discharged only via combined sewer overflows, this means a median duration of approximately 10 days per year. In general, stormwater outlets contribute more to the calculated effect than combined sewer overflows for rainfall-mobilized substances. We further evaluate the Urban Index (A urban,impervious /A natural ) as a proxy for critical discharge points: catchments where Triclosan and Copper exceed the corresponding environmental quality standard often have an Urban Index >0.03. A dynamic substance flow analysis allows us to identify the most critical discharge points to be prioritized for more detailed analyses and monitoring. This forms a basis for the efficient mitigation of pollution. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. 33 CFR 157.12d - Technical specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pipe runs full of liquid at all times during the discharge of the effluent. Sampling probes must... line as appropriate, so as to be always filled with the liquid being discharged. (2) A flow meter must... Design, Equipment, and Installation § 157.12d Technical specifications. (a) Oil discharge monitoring and...

  5. 33 CFR 157.12d - Technical specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pipe runs full of liquid at all times during the discharge of the effluent. Sampling probes must... line as appropriate, so as to be always filled with the liquid being discharged. (2) A flow meter must... Design, Equipment, and Installation § 157.12d Technical specifications. (a) Oil discharge monitoring and...

  6. Water resources data-California, water year 2004. volume 4. northern central valley basins and the Great Basin from Honey Lake basin to Oregon state line

    USGS Publications Warehouse

    Webster, M.D.; Rockwell, G.L.; Friebel, M.F.; Brockner, S.J.

    2005-01-01

    Water-resources data for the 2004 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 4 contains discharge records for 188 gaging stations, stage and contents for 62 lakes and reservoirs, gage-height records for 1 station, water quality for 20 streamflow-gaging stations and 1 partial-record stations. Also included are 4 miscellaneous partial-record sites. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  7. Water Resources Data--California, Water Year 2002, Volume 2, Pacific Slope Basins from Arroyo Grande to Oregon State Line except Central Valley

    USGS Publications Warehouse

    Freeman, L.A.; Smithson, J.R.; Webster, M.D.; Pope, G.L.; Friebel, M.F.

    2003-01-01

    Water-resources data for the 2002 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 2 contains discharge records for 133 gaging stations, stage and contents for 8 lakes and reservoirs, gage-height records for 6 stations, water quality for 43 streamflow-gaging stations and 5 partial-record stations. Also included are data for 1 low-flow partial-record station, and 5 miscellaneous-measurement stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  8. Water Resources Data for California, Water Year 1986. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Bowers, J.C.; McConaughy, C.E.; Polinoski, K.G.; Smith, G.B.

    1988-01-01

    Water resources data for the 1986 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 144 gaging stations; stage and contents for 15 lakes and reservoirs; watet quality for 21 streams. Also included are crest-stage partial-record stations, 3 miscellaneous measurement sites, and 5 water-quality partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  9. Water Resources Data for California, Water Year 1985. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Bowers, J.C.; McConaughy, C.E.; Polinoski, K.G.; Smith, G.B.

    1987-01-01

    Water resources data for the 1985 water year for California consists of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 150 gaging stations; stage and contents for 17 lakes and reservoirs; water quality for 23 streams. Also included are 10 crest-stage partial-record stations, three miscellaneous measurement sites, and one waterquality partial-record station. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  10. Type curves for selected problems of flow to wells in confined aquifers

    USGS Publications Warehouse

    Reed, J.E.

    1980-01-01

    This report presents type curves and related material for 11 conditions of flow to wells m confined aquifers. These solutions, compiled from hydrologic literature, span an interval of time from Theis (1935) to Papadopulos, Bredehoeft, and Cooper (1973). Solutions are presented for constant discharge, constant drawdown, and variable discharge for pumping wells that fully penetrate leaky and nonleaky aquifers. Solutions for wells that partially penetrate leaky and nonleaky aquifers are included. Also, solutions are included for the effect of finite well radius and the sudden injection of a volume of water for nonleaky aquifers. Each problem includes the partial differential equation, boundary and initial conditions, and solutions. Programs in FORTRAN for calculating additional function values are included for most of the solutions.

  11. Water resources data for california, water year 1992. Volume 1. Southern Great Basin from Mexican border to Mono lake basin, and pacific slope basins from Tijuana river to Santa Maria river. Water-data report (Annual), 1 October 1991-30 September 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, E.B.; Bowers, J.C.; Mullen, J.R.

    1993-09-01

    Water resources data for the 1992 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 161 streamflow-gaging stations, 15 crest-stage partial-record streamflow stations, and 5 miscellaneous measurement stations; (2) stage and contents records for 26 lakes and reservoirs; (3) water-quality records for 23 streamflow-gaging stations and 3 partial-record stations; and (4) precipitation records for 11 stations.

  12. Water resources data for California, water year 1993. Volume 1. Southern Great Basin from Mexican border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River. Water-data report (Annual), 1 October 1992-30 September 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mullen, J.R.; Hayes, P.D.; Agajanian, J.A.

    1994-06-01

    Water resources data for the 1993 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 156 streamflow-gaging stations, 12 crest-stage partial-record streamflow stations, and 5 miscellaneous measurement stations; (2) stage and contents records for 26 lakes and reservoirs; (3) water-quality records for 17 streamflow-gaging stations and 6 partial-record stations; and (4) precipitation records for 10 stations.

  13. Successful Outcome of Twin Gestation with Partial Mole and Co-Existing Live Fetus: A Case Report.

    PubMed

    Rathod, Setu; Rani, Reddi; John, Lopamudra B; Samal, Sunil Kumar

    2015-08-01

    Sad fetus syndrome comprising of a live twin gestation with a hydatidiform mole is a rare entity. The condition is even rarer when the co-existing live fetus is associated with a partial mole than a complete mole. We report the case of a 24-year-old G2P1L1 at 28 weeks gestation who presented to our casualty in the second stage of labour. She had a previous ultrasound scan at 13 weeks which showed a live fetus with a focal area of multicystic placenta. She delivered an alive preterm male fetus weighing 1.32 kg vaginally. Following expulsion of normal placenta of the live fetus, partial mole was expelled. The fetus was admitted to neonatal ICU and discharged after two weeks. Soon after delivery, β-hCG (human chorionic gonadotropin) was 1,21,993 mIU/ml which decreased to 30mIU/ml within two weeks. The patient was discharged with advice of regular follow up of β-hCG reports.

  14. A global plasma model for reactive deposition of compound films by modulated pulsed power magnetron sputtering discharges

    NASA Astrophysics Data System (ADS)

    Zheng, B. C.; Wu, Z. L.; Wu, B.; Li, Y. G.; Lei, M. K.

    2017-05-01

    A spatially averaged, time-dependent global plasma model has been developed to describe the reactive deposition of a TiAlSiN thin film by modulated pulsed power magnetron sputtering (MPPMS) discharges in Ar/N2 mixture gas, based on the particle balance and the energy balance in the ionization region, and considering the formation and erosion of the compound at the target surface. The modeling results show that, with increasing the N2 partial pressure from 0% to 40% at a constant working pressure of 0.3 Pa, the electron temperature during the strongly ionized period increases from 4 to 7 eV and the effective power transfer coefficient, which represents the power fraction that effectively heats the electrons and maintains the discharge, increases from about 4% to 7%; with increasing the working pressure from 0.1 to 0.7 Pa at a constant N2 partial pressure of 25%, the electron temperature decreases from 10 to 4 eV and the effective power transfer coefficient decreases from 8% to 5%. Using the modeled plasma parameters to evaluate the kinetic energy of arriving ions, the ion-to-neutral flux ratio of deposited species, and the substrate heating, the variations of process parameters that increase these values lead to an enhanced adatom mobility at the target surface and an increased input energy to the substrate, corresponding to the experimental observation of surface roughness reduction, the microstructure transition from the columnar structure to the dense featureless structure, and the enhancement of phase separation. At higher N2 partial pressure or lower working pressure, the modeling results demonstrate an increase in electron temperature, which shifts the discharge balance of Ti species from Ti+ to Ti2+ and results in a higher return fraction of Ti species, corresponding to the higher Al/Ti ratio of deposited films at these conditions. The modeling results are well correlated with the experimental observation of the composition variation and the microstructure transition of deposited TiAlSiN compound films, demonstrating the applicability of this approach in understanding the characteristics of reactive MPPMS discharges as well as the composition and microstructure of deposited compound films. The model for reactive MPPMS discharges has no special limitations and is applicable to high power impulse magnetron sputtering discharges as well.

  15. Toutle/Cowlitz River Sediment Budget

    DTIC Science & Technology

    2010-05-18

    Discharge Data, Partial Water Year Suspended Sediment Data, Partial Water Year USGS Gage No. Gage Name Drainage Area ( mi2 ) Water Year 1980s 1990s...Sediment mean cfs acre-ft tons/ mi2 tons/acre-ft 1982 - 1987 2,131 1,543,666 44,000 13.1 1988 - 1998 2,082 1,508,160 4,107 1.2 1999 - 2007 2,010

  16. Experimentally derived resistivity for dielectric samples from the CRRES internal discharge monitor

    NASA Technical Reports Server (NTRS)

    Green, Nelson W.; Frederickson, A. Robb; Dennison, J. R.

    2005-01-01

    Resistivity values were experimentally determined using charge storage methods for six samples remaining from the construction of the Internal Discharge Monitor (IDM) flown on the Combined Release and Radiation Effects Satellite (CRRES). Three tests were performed over a period of four to five weeks each in a vacuum of -5x10^-6 torr with an average temperature of -25 (deg)C to simulate a space environment.

  17. Unfavorable surgical outcomes in partial epilepsy with secondary bilateral synchrony: Intracranial electroencephalography study.

    PubMed

    Sunwoo, Jun-Sang; Byun, Jung-Ick; Moon, Jangsup; Lim, Jung-Ah; Kim, Tae-Joon; Lee, Soon-Tae; Jung, Keun-Hwa; Park, Kyung-Il; Chu, Kon; Kim, Manho; Chung, Chun-Kee; Jung, Ki-Young; Lee, Sang Kun

    2016-05-01

    Secondary bilateral synchrony (SBS) indicates bilaterally synchronous epileptiform discharges arising from a focal cortical origin. The present study aims to investigate SBS in partial epilepsy with regard to surgical outcomes and intracranial EEG findings. We retrospectively reviewed consecutive patients who underwent epilepsy surgery following extraoperative intracranial electroencephalography (EEG) study from 2008 to 2012. The presence of SBS was determined based upon the results of scalp EEG monitoring performed for presurgical evaluations. We reviewed scalp EEG, neuroimaging, intracranial EEG findings, and surgical outcomes in patients with SBS. We found 12 patients with SBS who were surgically treated for intractable partial epilepsy. Nine (75%) patients had lateralized ictal semiology and only two (16.6%) patients showed localized ictal onset in scalp EEG. Brain MRI showed epileptogenic lesion in three (25%) patients. Intracranial EEG demonstrated that ictal onset zone was widespread or non-localized in six (50%) patients. Low-voltage fast activity was the most common ictal onset EEG pattern. Rapid propagation of ictal onset was noted in 10 (83.3%) patients. Eleven patients underwent resective epilepsy surgery and only two patients (18.2%) achieved seizure-freedom (median follow-up 56 months). MRI-visible brain lesions were associated with favorable outcomes (p=0.024). Patients with SBS, compared to frontal lobe epilepsy without SBS, showed lesser localization in ictal onset EEG (p=0.029) and more rapid propagation during evolution of ictal rhythm (p=0.015). The present results suggested that resective surgery for partial epilepsy with SBS should be decided carefully, especially in case of nonlesional epilepsy. Poor localization and rapid spread of ictal onset were prominent in intracranial EEG, which might contribute to incomplete resection of the epileptogenic zone and poor surgical outcomes. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Hydrologic data and description of a hydrologic monitoring plan for the Borax Lake area, Oregon

    USGS Publications Warehouse

    Schneider, Tiffany Rae; McFarland, William D.

    1995-01-01

    Information from field visits was used to develop a monitoring plan. The plan would include monitoring Borax Lake by measuring discharge, stage, evaporation, temperature, and specific conductance; water-quality sampling and analysis; and monitoring shallow ground-water levels near Borax Lake using shallow piezometers. Minimally, one hot spring in North Borax Lake Spring Group 1 would be monitored for temperature and specific conductance and sampled for water-quality analysis. In addition, two flowing wells would be monitored for water levels, temperature, specific conductance, and discharge and sampled for water-quality analysis. The construction characteristics of these wells must be verified before long-term data collection begins. In the future, it may be helpful to monitor shallow and (or) deep observation wells drilled into the thermal aquifer to understand the possible effects of geothermal development on Borax Lake and nearby springs.

  19. DSM-flux: A new technology for reliable Combined Sewer Overflow discharge monitoring with low uncertainties.

    PubMed

    Maté Marín, Ainhoa; Rivière, Nicolas; Lipeme Kouyi, Gislain

    2018-06-01

    In the past ten years, governments from the European Union have been encouraged to collect volume and quality data for all the effluent overflows from separated stormwater and combined sewer systems that result in a significant environmental impact on receiving water bodies. Methods to monitor and control these flows require improvements, particularly for complex Combined Sewer Overflow (CSO) structures. The DSM-flux (Device for Stormwater and combined sewer flows Monitoring and the control of pollutant fluxes) is a new pre-designed and pre-calibrated channel that provides appropriate hydraulic conditions suitable for measurement of overflow rates and volumes by means of one water level gauge. In this paper, a stage-discharge relation for the DSM-flux is obtained experimentally and validated for multiple inflow hydraulic configurations. Uncertainties in CSO discharges and volumes are estimated within the Guide to the expression of Uncertainty in Measurement (GUM) framework. Whatever the upstream hydraulic conditions are, relative uncertainties are lower than 15% and 2% for the investigated discharges and volumes, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Structural, mechanical, electrical and wetting properties of ZrNx films deposited by Ar/N2 vacuum arc discharge: Effect of nitrogen partial pressure

    NASA Astrophysics Data System (ADS)

    Abdallah, B.; Naddaf, M.; A-Kharroub, M.

    2013-03-01

    Non-stiochiometric zirconium nitride (ZrNx) thin films have been deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures at different N2 partial pressure ratio. The microstructure, mechanical, electrical and wetting properties of these films are studied by means of X-ray diffraction (XRD), micro-Raman spectroscopy, Rutherford back scattering (RBS) technique, conventional micro-hardness testing, electrical resistivity, atomic force microscopy (AFM) and contact angle (CA) measurements. RBS results and analysis show that the (N/Zr) ratio in the film increases with increasing the N2 partial pressure. A ZrNx film with (Zr/N) ratio in the vicinity of stoichiometric ZrN is obtained at N2 partial pressure of 10%. XRD and Raman results indicate that all deposited films have strained cubic crystal phase of ZrN, regardless of the N2 partial pressure. On increasing the N2 partial pressure, the relative intensity of (1 1 1) orientation with respect to (2 0 0) orientation is seen to decrease. The effect of N2 partial pressure on micro-hardness and the resistivity of the deposited film is revealed and correlated to the alteration of grain size, crystallographic texture, stoichiometry and residual stress developed in the film. In particular, it is found that residual stress and nitrogen incorporation in the film play crucial role in the alteration of micro-hardness and resistivity respectively. In addition, CA and AFM results demonstrate that as N2 partial pressure increases, both the surface hydrophobicity and roughness of the deposited film increase, leading to a significant decrease in the film surface free energy (SFE).

  1. Classification of Partial Discharge Measured under Different Levels of Noise Contamination

    PubMed Central

    2017-01-01

    Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD) and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE) cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA) features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN), Adaptive Neuro-Fuzzy Inference System (ANFIS) and Support Vector Machine (SVM). It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination. PMID:28085953

  2. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Monitoring devices. 154.525... Monitoring devices. The COTP may require the facility to install monitoring devices if the installation of monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous...

  3. Turbidity and suspended sediment in the upper Esopus Creek watershed, Ulster County, New York

    USGS Publications Warehouse

    McHale, Michael R.; Siemion, Jason

    2014-01-01

    Discharge, SSC, and turbidity were strongly related at the Coldbrook site but not at every monitoring site. In general, relations between discharge and SSC and turbidity were strongest at sites with high SSCs, with the exception of Stony Clove Creek. Stony Clove Creek had high SSCs and turbidity regardless of discharge, and although concentrations and turbidity values generally increased with increasing discharge, the relation was not strong. Five of the six sites used to investigate the relations between SSC and laboratory turbidity had a coefficient of determination (r2) greater than 0.7. Relations were not as strong between SSC and the turbidity measured by in situ probes because the period of record was shorter and therefore the sample sizes were smaller. Data from in situ turbidity probes were strongly related to turbidity data measured in the laboratory for all but one of the monitoring sites where the relation was strongly leveraged by one sample. Although the in situ turbidity probes appeared to provide a good surrogate for SSC and could allow more accurate calculations of suspended-sediment load than discrete suspended-sediment samples alone, more data would be required to define the regression models throughout the range in discharge, SSCs, and turbidity levels that occur at each monitoring site. Nonetheless, the in situ probes provided much greater detail about the relation between discharge and turbidity than did the grab samples and storm samples measured in the laboratory.

  4. Plasma Jet Interactions with Liquids in Partial Fulfillment of an NRL Karles Fellowship

    DTIC Science & Technology

    2015-11-30

    deposition), modify (e.g., chemical functionalization), and etch (in Si technology) materials. In low- pressure non- equilibrium discharge plasmas... equilibrium discharge plasmas, associated with the above processes, the electron population is much more energetic than both the ions and neutral gas...to be crucial to the advancements of these fields1, 2. Background: Atmospheric-pressure, non- equilibrium (APNE) plasmas, like low-pressure plasmas

  5. System for Measuring Conditional Amplitude, Phase, or Time Distributions of Pulsating Phenomena

    PubMed Central

    Van Brunt, Richard J.; Cernyar, Eric W.

    1992-01-01

    A detailed description is given of an electronic stochastic analyzer for use with direct “real-time” measurements of the conditional distributions needed for a complete stochastic characterization of pulsating phenomena that can be represented as random point processes. The measurement system described here is designed to reveal and quantify effects of pulse-to-pulse or phase-to-phase memory propagation. The unraveling of memory effects is required so that the physical basis for observed statistical properties of pulsating phenomena can be understood. The individual unique circuit components that comprise the system and the combinations of these components for various measurements, are thoroughly documented. The system has been applied to the measurement of pulsating partial discharges generated by applying alternating or constant voltage to a discharge gap. Examples are shown of data obtained for conditional and unconditional amplitude, time interval, and phase-of-occurrence distributions of partial-discharge pulses. The results unequivocally show the existence of significant memory effects as indicated, for example, by the observations that the most probable amplitudes and phases-of-occurrence of discharge pulses depend on the amplitudes and/or phases of the preceding pulses. Sources of error and fundamental limitations of the present measurement approach are analyzed. Possible extensions of the method are also discussed. PMID:28053450

  6. 40 CFR Appendix B to Part 434 - Baseline Determination and Compliance Monitoring for Pre-existing Discharges at Remining Operations

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Rather than assign one a rank of 2 and the other a rank of 3, the average of 2 and 3 (i.e., 2.5) is given... baseline and monitoring (i.e., n = 12 and m = 12), the critical value C is 99. (f) Compare C to Sn. If Sn... Discharges at Remining Operations I. General Procedure Requirements a. This appendix presents the procedures...

  7. 40 CFR Appendix B to Part 434 - Baseline Determination and Compliance Monitoring for Pre-existing Discharges at Remining Operations

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Rather than assign one a rank of 2 and the other a rank of 3, the average of 2 and 3 (i.e., 2.5) is given... baseline and monitoring (i.e., n = 12 and m = 12), the critical value C is 99. (f) Compare C to Sn. If Sn... Discharges at Remining Operations I. General Procedure Requirements a. This appendix presents the procedures...

  8. Methods for chemical analysis of water and wastes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-03-01

    This manual provides test procedures approved for the monitoring of water supplies, waste discharges, and ambient waters, under the Safe Drinking Water Act, the National Pollutant Discharge Elimination System, and Ambient Monitoring Requirements of Section 106 and 208 of Public Law 92-500. The test methods have been selected to meet the needs of federal legislation and to provide guidance to laboratories engaged in the protection of human health and the aquatic environment.

  9. Stormwater Collection, Treatment, Recycling and Reuse in a Shipyard

    DTIC Science & Technology

    1999-05-26

    effluent is monitored as if it was a confined, discrete source. Where tributyltin ( TBT ) paint is removed or applied to ships, it is one of the...ppt TBT limit). Based on NURP findings and the monitoring requirements of many shipyards, it would appear that copper, zinc, and lead would be likely...candidates for numeric limits on stormwater discharges. Stormwater discharge limits for tributyl tin ( TBT ) may also occur in the future; limits of 50

  10. Hydrogeologic data from a shallow flooding demonstration project, Twitchell Island, California, 1997-2001

    USGS Publications Warehouse

    Gamble, James M.; Burow, Karen R.; Wheeler, Gail A.; Hilditch, Robert; Drexler, Judy Z.

    2003-01-01

    Data were collected during a study to determine the effects of continuous shallow flooding on ground-water discharge to an agricultural drainage ditch on Twitchell Island, California. The conceptual model of the hydrogeologic setting was detailed with soil coring and borehole-geophysical logs. Twenty-two monitoring wells were installed to observe hydraulic head. Ten aquifer slug tests were done in peat and mineral sediments. Ground-water and surface-water temperature was monitored at 14 locations. Flow to and from the pond was monitored through direct measurement of flows and through the calculation of a water budget. These data were gathered to support the development of a two-dimensional ground-water flow model. The model will be used to estimate subsurface discharge to the drainage ditch as a result of the pond. The estimated discharge will be used to estimate the concentrations of DOC that can be expected in the ditch.

  11. Self-monitoring for atrial fibrillation recurrence in the discharge period post-cardiac surgery using an iPhone electrocardiogram.

    PubMed

    Lowres, Nicole; Mulcahy, Georgina; Gallagher, Robyn; Ben Freedman, Saul; Marshman, David; Kirkness, Ann; Orchard, Jessica; Neubeck, Lis

    2016-07-01

    Postoperative atrial fibrillation (POAF) occurs in 25-40% of patients following cardiac surgery, and is associated with a significant increased risk of stroke and mortality. Routine surveillance is not performed post-discharge; however, recurrence of POAF can occur in up to 30% of patients discharged in sinus rhythm. This study aimed to determine the feasibility of patients self-monitoring with an iPhone handheld electrocardiogram (iECG) to identify recurrence of POAF in the post-discharge period following cardiac surgery. Patients with POAF following cardiac surgery were eligible for participation if they had no prior history of atrial fibrillation (AF) and were discharged home in stable sinus rhythm. Participants were provided with an iECG and asked to record a 30-s iECG, four times per day for 4 weeks post-discharge. iECGs were automatically transmitted to a secure server, and reviewed for the presence of AF by the research team and a validated algorithm. All participants also received brief education on AF. Forty-two participants completed the intervention (mean age 69 ± 9 years, 80% male). Self-monitoring for POAF recurrence using an iECG was feasible and acceptable, and participants felt empowered. Self-monitoring identified 24% (95% confidence interval, 12-39%) with an AF recurrence within 17 days of hospital discharge. These participants were significantly younger than those without AF recurrence (64 ± 7 vs 70 ± 10 years; P = 0.025), and had a significantly lower CHA2DS2-VASc score (2.3 ± 1.2 vs 3.7 ± 2.3; P = 0.007). However, 80% were at high enough stroke risk to warrant consideration of anticoagulation, i.e. CHA2DS2-VASc score ≥2. Only 30% of recurrences were associated with palpitations. Participation also improved AF knowledge from 6.4 ± 1.8 to 7.3 ± 1.8 (P = 0.02), of a total score of 10. Providing patients with an iECG is a non-invasive, inexpensive, convenient and feasible way to monitor for AF recurrence in post-cardiac surgery patients. It also provides a mechanism to provide knowledge about the condition and also potentially reduce anxiety. The success of patients using this technology also has implications for extending the use of iECG self-monitoring to other patient groups such as those undergoing antiarrhythmic interventions for AF. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Relationship between locked modes and thermal quenches in DIII-D

    NASA Astrophysics Data System (ADS)

    Sweeney, R.; Choi, W.; Austin, M.; Brookman, M.; Izzo, V.; Knolker, M.; La Haye, R. J.; Leonard, A.; Strait, E.; Volpe, F. A.; The DIII-D Team

    2018-05-01

    Locked modes are known to be one of the major causes of disruptions, but the physical mechanisms by which locking leads to disruptions are not well understood. Here we analyze the evolution of the temperature profile in the presence of multiple coexisting locked modes during partial and full thermal quenches. Partial quenches are often observed to be an initial, distinct stage in the full thermal quench. Near the onset of partial quenches, locked island O-points are observed to align with each other on the midplane, and their widths are sufficient to overlap each other, as indicated by the Chirikov parameter. Energy conservation analysis of one partial thermal quench shows that the energy lost is both radiated in the divertor region, and conducted or convected to the divertor. Nonlinear resistive magnetohydrodynamic simulations support the interpretation of stochastic fields causing a partial axisymmetric collapse, though the simulated temperature profile exhibits less degradation than the experimental profiles. In discharges with minimum values of the safety factor above  ∼1.2, locked modes are observed to self-stabilize by inducing, possibly via double tearing modes, a minor disruption that removes their neoclassical drive. These high q min discharges often exhibit relatively low ratios of the plasma internal inductance to the safety factor at 95% of the poloidal flux, which might imply classical stability, in agreement with the decay of the mode when the neoclassical drive is removed.

  13. Effect of oblique channel on discharge characteristics of 200-W Hall thruster

    NASA Astrophysics Data System (ADS)

    Ding, Yongjie; Peng, Wuji; Sun, Hezhi; Xu, Yu; Wei, Liqiu; Li, Hong; Zeng, Ming; Wang, Fufeng; Yu, Daren

    2017-02-01

    In an experiment involving a 200-W Hall thruster, partial ionization occurs in the plume area because of the extrapolation of the magnetic field. To improve the thruster performance, the concept of an oblique channel is proposed for improving the ionization degree in the plume area. Calculations performed using a Particle-in-cell (PIC) simulator and the experimental results both show that an oblique channel structure can reduce the wall loss. Compared with a straight channel under similar conditions of the discharge voltage and current, the ionization degree in the plume area, thrust, specific impulse, propellant utilization, and anode efficiency are improved by ˜20%. The oblique channel is an important design consideration for improving the partial ionization of the plume area in the thruster.

  14. Analysis of flow near a dug well in an unconfined aquifer

    NASA Astrophysics Data System (ADS)

    Sridharan, K.; Sathyanarayana, D.; Reddy, A. Siva

    1990-11-01

    A numerical analysis of flow to a dug well in an unconfined aquifer is made, taking into account well storage, elastic storage release, gravity drainage, anisotropy, partial penetration, vertical flow and seepage surface at the well face, and treating the water table in the aquifer and water level in the well as unknown boundaries. The pumped discharge is maintained constant. The solution is obtained by a two-level iterative scheme. The effects of governing parameters on the drawdown, development of seepage surface and contribution from aquifer flow to the total discharge are discussed. The degree of anisotropy and partial penetration are found to be the parameters which affect the flow characteristics most significantly. The effect of anisotropy on the development of seepage surface is very pronounced.

  15. Water Resources Data -- California, Water Year 2003, Volume 1, Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Pope, G.L.; Agajanian, J.; Caldwell, L.A.; Rockwell, G.L.

    2004-01-01

    Water-resources data for the 2003 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 193 gaging stations and 11 crest-stage partial-record stations, stage and contents for 22 lakes and reservoirs, gage-height records for 2 stations, water quality for 47 streamflow-gaging stations and 12 partial-record stations, and precipitation data for 1 station. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  16. Water Resources Data--California, Water Year 2001, Volume 1, Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Agajanian, J.; Rockwell, G.L.; Anderson, S.W.; Pope, G.L.

    2002-01-01

    Water-resources data for the 2001 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 180 gaging stations and 13 crest-stage partial-record stations, stage and contents for 20 lakes and reservoirs, gage-height records for 2 stations, water quality for 37 streamflow-gaging stations and 2 partial-record stations, and precipitation data for 3 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  17. Water Resources Data--California, Water Year 2002, Volume 1, Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Rockwell, G.L.; Pope, G.L.; Agajanian, J.; Caldwell, L.A.

    2003-01-01

    Water-resources data for the 2002 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 188 gaging stations and 10 crest-stage partial-record stations, stage and contents for 19 lakes and reservoirs, gage-height records for 2 stations, water quality for 39 streamflow-gaging stations and 11 partial-record stations, and precipitation data for 1 station. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  18. Water Resources Data, California, Water Year 1994. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Hayes, P.D.; Agajanian, J.A.; Rockwell, G.L.

    1995-01-01

    Water resources data for the 1994 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 143 streamflow-gaging stations, 15 crest-stage partial-record streamflow stations; (2) stage and contents records for 20 lakes and reservoirs; (3) water quality records for 19 streamflow-gaging stations and 2 partial-record stations; and ( 4) precipitation records for 8 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  19. Water resources data, California, water year 2004, volume 1: Southern Great Basin from Mexican border to Mono Lake Basin, and Pacific Slope basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Agajanian, J.; Caldwell, L.A.; Rockwell, G.L.; Pope, G.L.

    2005-01-01

    Water-resources data for the 2004 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 195 gaging stations and 10 crest-stage partial-record stations, stage and contents for 25 lakes and reservoirs, gage-height records for 2 stations, water quality for 47 streamflow-gaging stations and 7 partial-record stations, and precipitation data for 5 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  20. Water Resources Data for California, Water Year 1988. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Polinoski, K.G.; Hoffman, E.B.; Smith, G.B.; Bowers, J.C.

    1989-01-01

    Water resources data for the 1988 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 134 gaging stations; stage and contents for 17 lakes and reservoirs; and water quality for 24 streams. Also included are 10 crest-stage partial-record stations, 5 miscellaneous measurement sites, and 16 water-quality partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  1. Water Resources Data, California, Water Year 1990. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin; and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Bowers, J.C.; Jensen, R.M.; Hoffman, E.B.

    1991-01-01

    Water resources data for the 1990 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 157 streamflow-gaging stations, 16 crest-stage partial-record streamflow stations, and 2miscellaneous measurement stations; stage and contents records for 16 lakes and reservoirs; water-quality records for 19 streamflow-gaging stations, 2 partial-record stations; and precipitation records for 13 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  2. Water Resources Data, California, Water Year 1995. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin; and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Agajanian, J.A.; Rockwell, G.L.; Hayes, P.D.

    1996-01-01

    Water resources data for the 1995 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 141 streamflow-gaging stations, 6 crest-stage partial-record streamflow stations; (2) stage and contents records for 20 lakes and reservoirs; (3) water quality records for 21 streamflow-gaging stations and 3 partial-record stations; and (4) precipitation records for 1 station. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  3. Water Resources Data for California, Water Year 1987. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Bowers, J.C.; McConaughy, C.E.; Polinoski, K.G.; Smith, G.B.

    1988-01-01

    Water resources data for the 1987 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 134 gaging stations; stage and contents for 16 lakes and reservoirs; and water quality for 16 streams. Also included are 10 crest-stage partial-record stations, 3 miscellaneous measurement sites, and 10 water-quality partial-record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  4. Water Resources Data, California, Water Year 1989. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin; and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Hoffman, E.B.; Bowers, J.C.; Jensen, R.M.

    1990-01-01

    Water resources data for the 1989 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains discharge records for 137 gaging stations; stage and contents for 15 lakes and reservoirs; water quality for 25 streams; and precipitation for 8 gaging stations. Also included are 15 crest-stage partial-record stations, 7 miscellaneous measurement sites, and 5 water-quality partial record stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  5. Water Resources Data, California, Water Year 1996. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Rockwell, G.L.; Hayes, P.D.; Agajanian, J.A.

    1997-01-01

    Water-resources data for the 1996 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 149 gaging stations and 6 crest-stage partial-record stations, stage and contents for 21 lakes and reservoirs, gage height records for 1 station, water quality for 19 streamflow-gaging stations and 17 partial record stations, and precipitation data for 4 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  6. Water Resources Data--California, Water Year 2000, Volume 1, Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Anderson, S.W.; Agajanian, J.; Rockwell, G.L.

    2001-01-01

    Water-resources data for the 2000 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 175 gaging stations and 13 crest-stage partial-record stations, stage and contents for 20 lakes and reservoirs, gage-height records for 2 stations, water quality for 27 streamflow-gaging stations and 3 partial-record stations, and precipitation data for 4 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  7. Discharge formation in a XеCl laser pumped by high specific power

    NASA Astrophysics Data System (ADS)

    Panchenko, Yu. N.; Losev, V. F.

    2013-02-01

    Stable glow of the discharge of various types in the gas mixture of a XeCl laser is investigated for specific pumping power in the range 1.2-4.6 MW/cm3 and pulse duration of 40 ns. It is demonstrated that formation of partially homogeneous plasma with many intensive cathode spots on the electrode allows the maximum energy and duration of the lasing pulse to be obtained with laser efficiency of 2.4%. It is revealed that for the specific pumping powers up to 1.5 MW/cm3, a very homogeneous volume discharge with a small number of lowintensive cathode spots is formed in the discharge gap. With further increase in the specific pumping power exceeding 4.5 MW/cm3, current microinhomogeneities are formed in the volume discharge of this type leading to lasing breakdown.

  8. 40 CFR 60.284a - Monitoring of emissions and operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... located close to the scrubber liquid discharge point. The Administrator may be consulted for approval of... record the opacity of the gases discharged into the atmosphere from any recovery furnace or lime kiln... emissions on a dry basis and the percent of oxygen by volume on a dry basis in the gases discharged into the...

  9. Teaching the Hydrologic and Geomorphic Significance of Drainage Basins and Discharge in Physical Geography.

    ERIC Educational Resources Information Center

    Sutherland, Ross

    1994-01-01

    States that drainage basins, stream discharge, and sediment discharge are fundamental concepts in physical geography and integral parts of other cognate disciplines. Presents two exercises about these concepts. Includes a set of field-based exercises and a set of exercises for students who are unable to conduct field monitoring. (CFR)

  10. Environmental concerns of desalinating seawater using reverse osmosis.

    PubMed

    Tularam, Gurudeo Anand; Ilahee, Mahbub

    2007-08-01

    This Critical Review on environmental concerns of desalination plants suggests that planning and monitoring stages are critical aspects of successful management and operation of plants. The site for the desalination plants should be selected carefully and should be away from residential areas particularly for forward planning for possible future expansions. The concerning issues identified are noise pollution, visual pollution, reduction in recreational fishing and swimming areas, emission of materials into the atmosphere, the brine discharge and types of disposal methods used are the main cause of pollution. The reverse osmosis (RO) method is the preferred option in modern times especially when fossil fuels are becoming expensive. The RO has other positives such as better efficiency (30-50%) when compared with distillation type plants (10-30%). However, the RO membranes are susceptible to fouling and scaling and as such they need to be cleaned with chemicals regularly that may be toxic to receiving waters. The input and output water in desalination plants have to be pre and post treated, respectively. This involves treating for pH, coagulants, Cl, Cu, organics, CO(2), H(2)S and hypoxia. The by-product of the plant is mainly brine with concentration at times twice that of seawater. This discharge also includes traces of various chemicals used in cleaning including any anticorrosion products used in the plant and has to be treated to acceptable levels of each chemical before discharge but acceptable levels vary depending on receiving waters and state regulations. The discharge of the brine is usually done by a long pipe far into the sea or at the coastline. Either way the high density of the discharge reaches the bottom layers of receiving waters and may affect marine life particularly at the bottom layers or boundaries. The longer term effects of such discharge concentrate has not been documented but it is possible that small traces of toxic substances used in the cleaning of RO membranes may be harmful to marine life and ecosystem. The plants require saline water and thus the construction of input and discharge output piping is vital. The piping are often lengthy and underground as it is in Tugun (QLD, Australia), passing below the ground. Leakage of the concentrate via cracks in rocks to aquifers is a concern and therefore appropriate monitoring quality is needed. Leakage monitoring devices ought to be attached to such piping during installation. The initial environment impact assessment should identify key parameters for monitoring during discharge processes and should recommend ongoing monitoring with devices attached to structures installed during construction of plants.

  11. Wesco Operating Inc., Lander Field NPDES Proposed Permit

    EPA Pesticide Factsheets

    Indian Country, Minor, indust., non-discharge, proposed permit WY-0000221 establishes monitoring and reporting provisions should an unauthorized release of produced water occur from the Wesco Operating, Inc., Lander Field NW Discharge oil production site.

  12. Depression, worry, and psychosocial functioning predict eating disorder treatment outcomes in a residential and partial hospitalization setting.

    PubMed

    Fewell, Laura K; Levinson, Cheri A; Stark, Lynn

    2017-06-01

    This retrospective study explores depression, worry, psychosocial functioning, and change in body mass index (BMI) as predictors of eating disorder (ED) symptomatology and BMI at discharge and 1-year follow-up from a residential and partial hospitalization ED treatment center. Participants were 423 male and female patients receiving treatment at an ED treatment center. Results indicate significant improvement in ED symptomatology, psychological impairment, and change in BMI (in patients with anorexia nervosa) at treatment discharge and follow-up compared to treatment admission (ps < 0.001). Depression and worry predicted ED symptomatology and psychological impairment at discharge (ps < 0.05). Depression, worry, and psychosocial functioning predicted ED symptomatology and psychological impairment at 1-year follow-up (ps < 0.001). Change in BMI was not a significant predictor of outcome. Depression, worry, and psychosocial functioning each play a role in treatment outcomes and may help clarify who might benefit from treatment. Clinicians in ED treatment centers should consider these as areas of focus for improved outcomes.

  13. Impact of different environmental conditions on lithium-ion batteries performance through the thermal monitoring with fiber sensors

    NASA Astrophysics Data System (ADS)

    Nascimento, Micael; Ferreira, Marta S.; Pinto, João. L.

    2017-08-01

    In this work, an optical fiber sensing network has been developed to assess the impact of different environmental conditions on lithium batteries performance through the real time thermal monitoring. The battery is submitted to constant current charge and different discharge C-rates, under normal and abusive operating conditions. The results show that for the discharge C-rate of 5.77C, the LiB under cold and dry climates had 32.5% and 27.2% lower temperature variations, when compared with temperate climates, respectively. The higher temperature shift detected in the temperate climate was related to the battery better performance regarding discharge capacity and power capabilities.

  14. Non-Destructive Monitoring of Charge-Discharge Cycles on Lithium Ion Batteries using 7Li Stray-Field Imaging

    PubMed Central

    Tang, Joel A.; Dugar, Sneha; Zhong, Guiming; Dalal, Naresh S.; Zheng, Jim P.; Yang, Yong; Fu, Riqiang

    2013-01-01

    Magnetic resonance imaging provides a noninvasive method for in situ monitoring of electrochemical processes involved in charge/discharge cycling of batteries. Determining how the electrochemical processes become irreversible, ultimately resulting in degraded battery performance, will aid in developing new battery materials and designing better batteries. Here we introduce the use of an alternative in situ diagnostic tool to monitor the electrochemical processes. Utilizing a very large field-gradient in the fringe field of a magnet, stray-field-imaging (STRAFI) technique significantly improves the image resolution. These STRAFI images enable the real time monitoring of the electrodes at a micron level. It is demonstrated by two prototype half-cells, graphite∥Li and LiFePO4∥Li, that the high-resolution 7Li STRAFI profiles allow one to visualize in situ Li-ions transfer between the electrodes during charge/discharge cyclings as well as the formation and changes of irreversible microstructures of the Li components, and particularly reveal a non-uniform Li-ion distribution in the graphite. PMID:24005580

  15. Relations of Water Quality to Streamflow, Season, and Land Use for Four Tributaries to the Toms River, Ocean County, New Jersey, 1994-99

    USGS Publications Warehouse

    Baker, Ronald J.; Hunchak-Kariouk, Kathryn

    2006-01-01

    The effects of nonpoint-source contamination on the water quality of four tributaries to the Toms River in Ocean County, New Jersey, have been investigated in a 5-year study by the U.S. Geological Survey (USGS), in cooperation with the New Jersey Department of Environmental Protection (NJDEP). The purpose of the study was to relate the extent of land development to loads of nutrients and other contaminants to these streams, and ultimately to Barnegat Bay. Volumetric streamflow (discharge) was measured at 6 monitoring sites during 37 stormflow and base-flow sampling events over a 5-year period (May 1994-September 1999). Concentrations and yields (area-normalized instantaneous load values) of nitrogen and phosphorus species, total suspended solids, and fecal coliform bacteria were quantified, and pH, dissolved oxygen, and stream stage were monitored during base-flow conditions and storms. Sufficient data were collected to allow for a statistical evaluation of differences in water quality among streams in subbasins with high, medium, and low levels of land development. Long Swamp Creek, in a highly developed subbasin (64.2 percent developed); Wrangle Brook, in a moderately developed subbasin (34.5 percent); Davenport Branch, in a slightly developed subbasin (22.8 percent); and Jakes Branch, in an undeveloped subbasin (0 percent) are the subbasins selected for this study. No point-source discharges are known to be present on these streams. Water samples were collected and analyzed by the NJDEP, and discharge measurements and data analysis were conducted by the USGS. Total nitrogen concentrations were lower in Davenport Branch than in Long Swamp Creek and Wrangle Brook during base flow and stormflow. Concentrations of total nitrogen and nitrate were highest in Wrangle Brook (as high as 3.0 mg/L and 1.6 mg/L, respectively) as a result of high concentrations of nitrate in samples collected during base flow; nitrate loading from ground-water discharge is much higher in Wrangle Brook than in any of the other streams, possibly as a result of an experimental wastewater-(secondary effluent) disposal site that was in operation during the 1980's. Ammonia concentrations were higher in samples from Long Swamp Creek than in those from the other two monitoring sites under all flow conditions, and ammonia yields were higher during stormflow than base flow at all monitoring sites. Concentrations and yields of fecal coliform bacteria and total suspended solids were higher during stormflow than during base flow at all monitoring sites. Concentrations and yields were significantly higher in Long Swamp Creek, a highly developed subbasin and Wrangle Brook, a moderately developed subbasin than in Davenport Branch, a slightly developed subbasin. Concentrations and yields of phosphate species, which also are strongly related to stormflow, were higher during stormflow in Long Swamp Creek than in the other subbasins. Base-flow separation techniques were used on hydrographs generated for storms to distinguish the fraction of discharge and constituent loading attributable to storm runoff (overland flow) from the fraction contributed by ground-water discharge. Precipitation records were used to determine the total annual volumes of ground-water discharge and runoff at each monitoring site. These volumes were used in conjunction with water-quality data to calculate total annual loads of each constituent at each monitoring site, separated into ground-water discharge and runoff fractions. It was determined that loads of ammonia, nitrate, organic nitrogen, total nitrogen, and orthophosphate in ground-water discharge were significantly higher in the moderately developed Wrangle Brook subbasin than in the highly developed Long Swamp Creek subbasin, and that no relation was apparent between the percent of land development and constituent loads from ground-water discharge. The loading of each constituent contributed by ground-water discharge is specific

  16. Hydrology of the North Klondike River: carbon export, water balance and inter-annual climate influences within a sub-alpine permafrost catchment.

    PubMed

    Lapp, Anthony; Clark, Ian; Macumber, Andrew; Patterson, Tim

    2017-10-01

    Arctic and sub-arctic watersheds are undergoing significant changes due to recent climate warming and degrading permafrost, engendering enhanced monitoring of arctic rivers. Smaller catchments provide understanding of discharge, solute flux and groundwater recharge at the process level that contributes to an understanding of how larger arctic watersheds are responding to climate change. The North Klondike River, located in west central Yukon, is a sub-alpine permafrost catchment, which maintains an active hydrological monitoring station with a record of >40 years. In addition to being able to monitor intra-annual variability, this data set allows for more complex analysis of streamflow records. Streamflow data, geochemistry and stable isotope data for 2014 show a groundwater-dominated system, predominantly recharged during periods of snowmelt. Radiocarbon is shown to be a valuable tracer of soil zone recharge processes and carbon sources. Winter groundwater baseflow contributes 20 % of total annual discharge, and accounts for up to 50 % of total river discharge during the spring and summer months. Although total stream discharge remains unchanged, mean annual groundwater baseflow has increased over the 40-year monitoring period. Wavelet analysis reveals a catchment that responds to El Niño and longer solar cycles, as well as climatic shifts such as the Pacific Decadal Oscillation. Dedicated to Professor Peter Fritz on the occasion of his 80th birthday.

  17. The Impact of Race on Discharge Disposition and Length of Hospitalization After Craniotomy for Brain Tumor.

    PubMed

    Muhlestein, Whitney E; Akagi, Dallin S; Chotai, Silky; Chambless, Lola B

    2017-08-01

    Racial disparities exist in health care, frequently resulting in unfavorable outcomes for minority patients. Here, we use guided machine learning (ML) ensembles to model the impact of race on discharge disposition and length of stay (LOS) after brain tumor surgery from the Healthcare Cost and Utilization Project National Inpatient Sample. We performed a retrospective cohort study of 41,222 patients who underwent craniotomies for brain tumors from 2002 to 2011 and were registered in the National Inpatient Sample. Twenty-six ML algorithms were trained on prehospitalization variables to predict non-home discharge and extended LOS (>7 days) after brain tumor resection, and the most predictive algorithms combined to create ensemble models. Partial dependence analysis was performed to measure the independent impact of race on the ensembles. The guided ML ensembles predicted non-home disposition (area under the curve, 0.796) and extended LOS (area under the curve, 0.824) with good discrimination. Partial dependence analysis showed that black race increases the risk of non-home discharge and extended LOS over white race by 6.9% and 6.5%, respectively. Other, nonblack race increases the risk of extended LOS over white race by 6.0%. The impact of race on these outcomes is not seen when analyzing the general inpatient or general operative population. Minority race independently increases the risk of extended LOS and black race increases the risk of non-home discharge in patients undergoing brain tumor resection, a finding not mimicked in the general inpatient or operative population. Recognition of the influence of race on discharge and LOS could generate interventions that may improve outcomes in this population. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Differentiated spring behavior under changing hydrological conditions in an alpine karst aquifer

    NASA Astrophysics Data System (ADS)

    Filippini, Maria; Squarzoni, Gabriela; De Waele, Jo; Fiorucci, Adriano; Vigna, Bartolomeo; Grillo, Barbara; Riva, Alberto; Rossetti, Stefano; Zini, Luca; Casagrande, Giacomo; Stumpp, Christine; Gargini, Alessandro

    2018-01-01

    Limestone massifs with a high density of dolines form important karst aquifers in most of the Alps, often with groundwater circulating through deep karst conduits and water coming out of closely spaced springs with flow rates of over some cubic meters per second. Although several hydrogeological studies and tracing experiments were carried out in many of these carbonate mountains in the past, the hydrogeology of most of these karst aquifers is still poorly known. Geological, hydrodynamic and hydrochemical investigations have been carried out in one of the most representative of these areas (Cansiglio-Monte Cavallo, NE Italy) since spring 2015, in order to enhance the knowledge on this important type of aquifer system. Additionally, a cave-to-spring multitracer test was carried out in late spring 2016 by using three different fluorescent tracers. This hydrogeological study allowed: 1) gathering new detailed information on the geological and tectonic structure of such alpine karst plateau; 2) defining discharge rates of the three main springs (Gorgazzo, Santissima, and Molinetto) by constructing rating curves; 3) understanding the discharging behavior of the system with respect to different recharge conditions; 4) better defining the recharge areas of the three springs. The three nearby springs (the spring front stretches over 5 km), that drain the investigated karst aquifer system, show different behaviors with respect to changing discharge conditions, demonstrating this aquifer to be divided in partially independent drainage systems under low-flow conditions, when their chemistry is clearly differentiated. Under high-flow conditions, waters discharging at all springs show more similar geochemical characteristics. The combination of geochemistry, hydrodynamic monitoring and dye tracing tests has shown that the three springs have different recharge areas. The study points out that even closely spaced karst springs, that apparently drain the same karst mountain, can have different behaviors, and thus distinctive reactions toward polluting events, a characteristic to be taken into account for their management.

  19. Discharge and suspended sediment patterns in a small mountainous watershed with widely distributed rock fragments

    NASA Astrophysics Data System (ADS)

    Fang, N. F.; Shi, Z. H.; Chen, F. X.; Zhang, H. Y.; Wang, Y. X.

    2015-09-01

    Understanding and quantifying sediment loads is important in watersheds with highly erodible materials, which will eventually cause environmental and ecological problems. Within this context, suspended sediment (SS) transport and its temporal dynamics were studied in a small mountainous watershed with sloping lands containing rock fragments in subtropical China. Soils containing rock fragments with many macro-pores have a high permeability rate. Over a 7-year period, the mean runoff coefficient of this watershed was 0.65. Overall, 30 flood events were monitored and accounted for 95.5%, 27.3%, 17.1% of the total SS load, precipitation and total discharge, respectively, over a 5-year period. The presence of rock fragments in soils can affect soil loss. When comparing the soil loss in the studied watershed with that of other watersheds under similar climatic conditions, rock fragments negatively affect soil loss. However, an extreme event occurred on 14 August 1990, and the sediment load exhibited a phenomenon called "small deposits towards lump withdrawal", which resulted in a soil loss of 20,499 t (4.6 times the mean yearly soil loss). This event exhausted most of the SSs stored by the rock fragments on the slope and channel. Following this event, the mean SS concentration (SSC) of the 11 events was 1.05 kg m-3, and the mean SSC of the 18 previous events was 1.75 kg m-3. Twelve variables were separated using the classical hydrograph separation method. Partial least-squares regression (PLSR) was used to determine the highly co-related variables of the discharge. The results indicated that PLSR could explain runoff well. The relationship between discharge and SSC was highly scattered. During 24 flood events, three types of hysteresis loops were observed: clockwise (17 events), figure-eight (3 events), and complex (4 events).

  20. 40 CFR 1065.195 - PM-stabilization environment for in-situ analyzers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... intervals recommended by the neutralizer manufacturer. (2) You may use other neutralizers, such as a corona-discharge ionizer. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net...

  1. 40 CFR 1065.195 - PM-stabilization environment for in-situ analyzers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... intervals recommended by the neutralizer manufacturer. (2) You may use other neutralizers, such as a corona-discharge ionizer. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net...

  2. 40 CFR 1065.190 - PM-stabilization and weighing environments for gravimetric analysis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... neutralizer manufacturer. (ii) You may use other neutralizers, such as corona-discharge ionizers. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net charge according to the...

  3. 40 CFR 1065.190 - PM-stabilization and weighing environments for gravimetric analysis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... recommended by the neutralizer manufacturer. (ii) You may use other neutralizers, such as corona-discharge ionizers. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net charge...

  4. 40 CFR 1065.190 - PM-stabilization and weighing environments for gravimetric analysis.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... neutralizer manufacturer. (ii) You may use other neutralizers, such as corona-discharge ionizers. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net charge according to the...

  5. 40 CFR 1065.190 - PM-stabilization and weighing environments for gravimetric analysis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... neutralizer manufacturer. (ii) You may use other neutralizers, such as corona-discharge ionizers. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net charge according to the...

  6. 40 CFR 1065.195 - PM-stabilization environment for in-situ analyzers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... intervals recommended by the neutralizer manufacturer. (2) You may use other neutralizers, such as a corona-discharge ionizer. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net...

  7. 40 CFR 1065.190 - PM-stabilization and weighing environments for gravimetric analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... recommended by the neutralizer manufacturer. (ii) You may use other neutralizers, such as corona-discharge ionizers. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net charge...

  8. 40 CFR 1065.195 - PM-stabilization environment for in-situ analyzers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... intervals recommended by the neutralizer manufacturer. (2) You may use other neutralizers, such as a corona-discharge ionizer. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net...

  9. 40 CFR 1065.195 - PM-stabilization environment for in-situ analyzers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... intervals recommended by the neutralizer manufacturer. (2) You may use other neutralizers, such as a corona-discharge ionizer. If you use a corona-discharge ionizer, we recommend that you monitor it for neutral net...

  10. Practical method for appearance match between soft copy and hard copy

    NASA Astrophysics Data System (ADS)

    Katoh, Naoya

    1994-04-01

    CRT monitors are often used as a soft proofing device for the hard copy image output. However, what the user sees on the monitor does not match its output, even if the monitor and the output device are calibrated with CIE/XYZ or CIE/Lab. This is especially obvious when correlated color temperature (CCT) of CRT monitor's white point significantly differs from ambient light. In a typical office environment, one uses a computer graphic monitor having a CCT of 9300K in a room of white fluorescent light of 4150K CCT. In such a case, human visual system is partially adapted to the CRT monitor's white point and partially to the ambient light. The visual experiments were performed on the effect of the ambient lighting. Practical method for soft copy color reproduction that matches the hard copy image in appearance is presented in this paper. This method is fundamentally based on a simple von Kries' adaptation model and takes into account the human visual system's partial adaptation and contrast matching.

  11. A computer-controlled, closed-loop infusion system for infusing muscle relaxants: its use during motor-evoked potential monitoring.

    PubMed

    Stinson, L W; Murray, M J; Jones, K A; Assef, S J; Burke, M J; Behrens, T L; Lennon, R L

    1994-02-01

    A microcomputer-controlled closed-loop infusion system (MCCLIS) has been developed that provides stable intraoperative levels of partial neuromuscular blockade. Complete neuromuscular blockade interferes with intraoperative motor-evoked potential (MEP) monitoring used for patients undergoing surgical procedures that place them at risk for spinal cord ischemia. Nine patients were studied during which the MCCLIS maintained stable levels of partial neuromuscular blockade and allowed transcranial magnetic motor-evoked potential (TcM-MEP) monitoring during thoracoabdominal aortic aneurysmectomy. The use of TcM-MEP for monitoring intraoperative spinal cord function was balanced against surgical considerations for muscle relaxation with 80% to 90% neuromuscular blockade fulfilling each requirement. Intraoperative adjustment of partial neuromuscular blockade to facilitate TcM-MEP monitoring was also possible with the MCCLIS. The MCCLIS should allow for further investigation into the sensitivity, specificity, and predictability of TcM-MEP monitoring for any patient at risk for intraoperative spinal cord ischemia including those undergoing thoracoabdominal aortic aneurysmectomy.

  12. Analysis of low flows and selected methods for estimating low-flow characteristics at partial-record and ungaged stream sites in western Washington

    USGS Publications Warehouse

    Curran, Christopher A.; Eng, Ken; Konrad, Christopher P.

    2012-01-01

    Regional low-flow regression models for estimating Q7,10 at ungaged stream sites are developed from the records of daily discharge at 65 continuous gaging stations (including 22 discontinued gaging stations) for the purpose of evaluating explanatory variables. By incorporating the base-flow recession time constant τ as an explanatory variable in the regression model, the root-mean square error for estimating Q7,10 at ungaged sites can be lowered to 72 percent (for known values of τ), which is 42 percent less than if only basin area and mean annual precipitation are used as explanatory variables. If partial-record sites are included in the regression data set, τ must be estimated from pairs of discharge measurements made during continuous periods of declining low flows. Eight measurement pairs are optimal for estimating τ at partial-record sites, and result in a lowering of the root-mean square error by 25 percent. A low-flow survey strategy that includes paired measurements at partial-record sites requires additional effort and planning beyond a standard strategy, but could be used to enhance regional estimates of τ and potentially reduce the error of regional regression models for estimating low-flow characteristics at ungaged sites.

  13. The probability of seizures during EEG monitoring in critically ill adults

    PubMed Central

    Westover, M. Brandon; Shafi, Mouhsin M.; Bianchi, Matt T.; Moura, Lidia M.V.R.; O’Rourke, Deirdre; Rosenthal, Eric S.; Chu, Catherine J.; Donovan, Samantha; Hoch, Daniel B.; Kilbride, Ronan D.; Cole, Andrew J.; Cash, Sydney S.

    2014-01-01

    Objective To characterize the risk for seizures over time in relation to EEG findings in hospitalized adults undergoing continuous EEG monitoring (cEEG). Methods Retrospective analysis of cEEG data and medical records from 625 consecutive adult inpatients monitored at a tertiary medical center. Using survival analysis methods, we estimated the time-dependent probability that a seizure will occur within the next 72-h, if no seizure has occurred yet, as a function of EEG abnormalities detected so far. Results Seizures occurred in 27% (168/625). The first seizure occurred early (<30 min of monitoring) in 58% (98/168). In 527 patients without early seizures, 159 (30%) had early epileptiform abnormalities, versus 368 (70%) without. Seizures were eventually detected in 25% of patients with early epileptiform discharges, versus 8% without early discharges. The 72-h risk of seizures declined below 5% if no epileptiform abnormalities were present in the first two hours, whereas 16 h of monitoring were required when epileptiform discharges were present. 20% (74/388) of patients without early epileptiform abnormalities later developed them; 23% (17/74) of these ultimately had seizures. Only 4% (12/294) experienced a seizure without preceding epileptiform abnormalities. Conclusions Seizure risk in acute neurological illness decays rapidly, at a rate dependent on abnormalities detected early during monitoring. This study demonstrates that substantial risk stratification is possible based on early EEG abnormalities. Significance These findings have implications for patient-specific determination of the required duration of cEEG monitoring in hospitalized patients. PMID:25082090

  14. Operation of a pond-cooler: the case of Berezovskaya GRES-1

    NASA Astrophysics Data System (ADS)

    Morozova, O. G.; Kamoza, T. L.; Koyupchenko, I. N.; Savelyev, A. S.; Pen, R. Z.; Veselkova, N. S.; Kudryavtsev, M. D.

    2017-08-01

    Pond-coolers at heat and nuclear power stations are natural-technological systems, so the program of their monitoring should include the effect made by the SRPS (state regional power station) on the pond ecosystem, including thermal discharge of cooling water. The objectives of this study were development and implementation of a monitoring program for the cooling pond of Berezovskaya SRPS-1 on the chemical and biological water quality indicators and identification of patterns of the thermal and hydrochemical regime when operating the progressive power plant (from 1996 to 2015). The quality of the cooling water of the pond-cooler BGRES-1 was studied under full-scale conditions by selecting and analyzing the water samples of the pond in accordance with the principles of complexity, systematic observation, and consistency of timing their conduct with the characteristic hydrological phases. Processing of the obtained array of monitoring data by methods of mathematical statistics makes it possible to identify the main factors affecting the water quality of the pond. The data on water quality obtained during their monitoring and mathematical processing over a long time interval are the scientific basis for forecasting the ecological state of the pond, which is necessary to economically ensure the efficient energy production and safety of water use. Recommendations proposed by these authors, including those partially already implemented, have been to prevent the development of eutrophication processes in the pond-cooler: the construction of a dam that cuts off the main peat massif and cleaning the river banks forming the cooling pond.

  15. Low flux laboratory test of the Internal Discharge Monitor (IDM) experiment intended for CRRES. [Combined Release and Rediation Effects Satellite

    NASA Technical Reports Server (NTRS)

    Coakley, P. G.; Treadaway, M. J.; Robinson, P. A., Jr.

    1985-01-01

    Twelve planar printed circuit board samples and four cable samples were exposed to a distributed electron source of 150 keV to 2.5 MeV at 4.5 pA/sq cm and were monitored for electron-caused EMP. Discharges were recorded on 10 of the 16 samples during the first 18 hours of testing (total incident fluence equaled 1.8 x 10 to the 12th e/sq cm).

  16. Partial discharges and breakdown in C3F8

    NASA Astrophysics Data System (ADS)

    Koch, M.; Franck, C. M.

    2014-10-01

    Traditional search processes of gases or gas mixtures for replacing SF6 involve time consuming measurements of partial discharges and breakdown behaviour for several voltage waveforms and different field configurations. Recently a model for prediction of this behaviour for SF6 was described in literature. The model only requires basic properties of the gas such as the critical field strength and the effective ionization coefficient, which can be obtained by swarm parameter measurements, and thermodynamic properties, which can be calculated. In this paper, we show for the well-known and electronegative gas octafluoropropane (C3F8) that it is possible to transfer the model developed for SF6 to this gas to describe the breakdown behaviour of C3F8. Thus the model can be beneficial in the screening process of new insulation gases.

  17. Water Resources Data, California, Water Year 1993. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin, and Pacific Slope Basins from Tijuana River to Santa Maria River

    USGS Publications Warehouse

    Mullen, J.R.; Hayes, P.D.; Agajanian, J.A.

    1994-01-01

    Water resources data for the 1993 water year for California consist of records of stage, discharge, and water quality of streams; stage and contents in lakes and reservoirs; and water levels and water quality in wells. Volume 1 contains (1) discharge records for 156 streamflow-gaging stations, 12 crest-stage partial-record streamflow stations, and 5 miscellaneous measurement stations; (2) stage and contents records for 26 lakes and reservoirs; (3) water-quality records for 17 streamflow-gaging stations and 6 partial-record stations; and (4) precipitation records for 10 stations . These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in California.

  18. Fundamental Study on Self-healing Insulation Performance of Silicone Rubber Affected by Local Breakdown

    NASA Astrophysics Data System (ADS)

    Hozumi, Naohiro; Nishioka, Koji; Suematsu, Takeshi; Murakami, Yoshinobu; Nagao, Masayuki; Sakata, Hiroshi

    Feasibility of self-healing insulation system was studied. A silicone rubber without filler was mounted on a glass substrate with a needle electrode. An ac voltage with 4 kV in rms was applied. The voltage was cut off when the tree had propagated into 150 micrometers in length. After the cut-off, the partial discharge inception voltage was periodically observed. The partial discharge inception voltage had once reduced into as low as 2 kV. However, it gradually increased with time, and finally exceeded the tree inception voltage (4 kV) when 30 - 60 hours had passed. It was also observed by optical microscope that the tree gradually disappeared in parallel with the recovery of the partial discharge inception voltage. The same phenomenon was observed even if 1 kV ac voltage had been continuously applied during the process of the recovery. A simulation using a needle-shaped void was performed in order to clarify the mechanism of the self-healing effect. It was observed that the tip of the needle-shaped void gradually got wet with a liquid material. It would be the result of "bleed-out" of the low molecular component included in the rubber. The tip of the void was finally filled with the liquid, however, the rest of the needle-shaped void stayed without being filled. In this type of tree, it was suggested that the self-healing effect is expected if the diameter of the tree did not exceed ca. 5 micrometers.

  19. Hydrologic data and description of a hydrologic monitoring plan for Medicine Lake Volcano, California

    USGS Publications Warehouse

    Schneider, Tiffany Rae; McFarland, W.D.

    1996-01-01

    A hydrologic reconnaissance of the Medicine Lake Volcano area was done to collect data needed for the design of a hydrologic monitoring plan. The reconnaissance was completed during two field trips made in June and September 1992, during which geothermal and hydrologic features of public interest in the Medicine Lake area were identified. Selected wells, springs, and geothermal features were located and documented, and initial water-level, discharge, temperature, and specific-conductance measurements were made. Lakes in the study area also were surveyed during the September field trip. Temperature, specific- conductance, dissolved oxygen, and pH data were collected by using a multiparameter probe. The proposed monitoring plan includes measurement of water levels in wells, discharge from springs, and lake stage, as well as analysis of well-,spring-, and lake-water quality. In determining lake-water quality, data for both stratified and unstratified conditions would be considered. (Data for stratified conditions were collected during the reconnaissance phase of this project, but data for unstratified conditions were not.) In addition, lake stage also would be monitored. A geothermal feature near Medicine Lake is a "hot spot" from which hot gases discharge from two distinct vents. Gas chemistry and temperature would be monitored in one of these vents.

  20. Correlations of turbidity to suspended-sediment concentration in the Toutle River Basin, near Mount St. Helens, Washington, 2010-11

    USGS Publications Warehouse

    Uhrich, Mark A.; Kolasinac, Jasna; Booth, Pamela L.; Fountain, Robert L.; Spicer, Kurt R.; Mosbrucker, Adam R.

    2014-01-01

    Researchers at the U.S. Geological Survey, Cascades Volcano Observatory, investigated alternative methods for the traditional sample-based sediment record procedure in determining suspended-sediment concentration (SSC) and discharge. One such sediment-surrogate technique was developed using turbidity and discharge to estimate SSC for two gaging stations in the Toutle River Basin near Mount St. Helens, Washington. To provide context for the study, methods for collecting sediment data and monitoring turbidity are discussed. Statistical methods used include the development of ordinary least squares regression models for each gaging station. Issues of time-related autocorrelation also are evaluated. Addition of lagged explanatory variables was used to account for autocorrelation in the turbidity, discharge, and SSC data. Final regression model equations and plots are presented for the two gaging stations. The regression models support near-real-time estimates of SSC and improved suspended-sediment discharge records by incorporating continuous instream turbidity. Future use of such models may potentially lower the costs of sediment monitoring by reducing time it takes to collect and process samples and to derive a sediment-discharge record.

  1. Water resources data West Virginia water wear 2001

    USGS Publications Warehouse

    Ward, S.M.; Taylor, B.C.; Crosby, G.R.

    2002-01-01

    Water-resources data for the 2001 water year for West Virginia consist of records of discharge and water quality of streams and water levels of observation wells. This report contains discharge records for 65 streamflow-gaging stations; discharge records provided by adjacent states for 7 streamflow-gaging stations; annual maximum discharge at 18 crest-stage partial-record stations; water-quality records for 4 stations; and water-level records for 10 observation wells. Locations of these sites are shown on figures 4 and 5. Additional water data were collected at various sites, not involved in the systematic data collection program, and are published as miscellaneous sites. These data represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in West Virginia.

  2. Photogrammetric discharge monitoring of small tropical mountain rivers - A case study at Rivière des Pluies, Réunion island

    NASA Astrophysics Data System (ADS)

    Stumpf, André; Augereau, Emmanuel; Delacourt, Christophe; Bonnier, Julien

    2016-04-01

    Reliable discharge measurements are indispensable for an effective management of natural water resources and floods. Limitations of classical current meter profiling and stage-discharge ratings have stimulated the development of more accurate and efficient gauging techniques. While new discharge measurements technologies such as acoustic doppler current profilers and large-scale image particle velocimetry (LSPIV) have been developed and tested in numerous studies, the continuous monitoring of small mountain rivers and discharge dynamics during strong meteorological events remains challenging. More specifically LSPIV studies are often focused on short-term measurements during flood events and there are still very few studies that address its use for long-term monitoring of small mountain rivers. To fill this gap this study targets the development and testing of largely autonomous photogrammetric discharge measurement system with a special focus on the application to small mountain river with high discharge variability and a mobile riverbed in the tropics. It proposes several enhancements among previous LSPIV methods regarding camera calibration, more efficient processing in image geometry, the automatic detection of the water level as well as the statistical calibration and estimation of the discharge from multiple profiles. To account for changes in the bed topography the riverbed is surveyed repeatedly during the dry seasons using multi-view photogrammetry or terrestrial laser scanners. The presented case study comprises the analysis of several thousand videos spanning over two and a half year (2013-2015) to test the robustness and accuracy of different processing steps. An analysis of the obtained results suggests that the quality of the camera calibration reaches a sub-pixel accuracy. The median accuracy of the watermask detections is F1=0.82, whereas the precision is systematically higher than the recall. The resulting underestimation of the water surface area and level leads to a systematic underestimation of the discharge and error rates of up to 25 %. However, the bias can be effectively removed using a least-square cross-calibration which reduces the error to a MAE of 6.39% and a maximum error of 16.18%. Those error rates are significantly lower than the uncertainties among multiple profiles (30%) and illustrate the importance of the spatial averaging from multiple measurements. The study suggests that LSPIV can already be considered as a valuable tool for the monitoring of torrential flows, whereas further research is still needed to fully integrate night-time observation and stereo-photogrammetric capabilities.

  3. Relationship between locked modes and thermal quenches in DIII-D

    DOE PAGES

    Sweeney, R.; Choi, W.; Austin, M.; ...

    2018-03-28

    Locked modes are known to be one of the major causes of disruptions, but the physical mechanisms by which locking leads to disruptions are not well understood. For this study, we analyze the evolution of the temperature profile in the presence of multiple coexisting locked modes during partial and full thermal quenches. Partial quenches are often observed to be an initial, distinct stage in the full thermal quench. Near the onset of partial quenches, locked island O-points are observed to align with each other on the midplane, and their widths are sufficient to overlap each other, as indicated by themore » Chirikov parameter. Energy conservation analysis of one partial thermal quench shows that the energy lost is both radiated in the divertor region, and conducted or convected to the divertor. Nonlinear resistive magnetohydrodynamic simulations support the interpretation of stochastic fields causing a partial axisymmetric collapse, though the simulated temperature profile exhibits less degradation than the experimental profiles. In discharges with minimum values of the safety factor above ~1.2, locked modes are observed to self-stabilize by inducing, possibly via double tearing modes, a minor disruption that removes their neoclassical drive. These high q min discharges often exhibit relatively low ratios of the plasma internal inductance to the safety factor at 95% of the poloidal flux, which might imply classical stability, in agreement with the decay of the mode when the neoclassical drive is removed.« less

  4. Relationship between locked modes and thermal quenches in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sweeney, R.; Choi, W.; Austin, M.

    Locked modes are known to be one of the major causes of disruptions, but the physical mechanisms by which locking leads to disruptions are not well understood. For this study, we analyze the evolution of the temperature profile in the presence of multiple coexisting locked modes during partial and full thermal quenches. Partial quenches are often observed to be an initial, distinct stage in the full thermal quench. Near the onset of partial quenches, locked island O-points are observed to align with each other on the midplane, and their widths are sufficient to overlap each other, as indicated by themore » Chirikov parameter. Energy conservation analysis of one partial thermal quench shows that the energy lost is both radiated in the divertor region, and conducted or convected to the divertor. Nonlinear resistive magnetohydrodynamic simulations support the interpretation of stochastic fields causing a partial axisymmetric collapse, though the simulated temperature profile exhibits less degradation than the experimental profiles. In discharges with minimum values of the safety factor above ~1.2, locked modes are observed to self-stabilize by inducing, possibly via double tearing modes, a minor disruption that removes their neoclassical drive. These high q min discharges often exhibit relatively low ratios of the plasma internal inductance to the safety factor at 95% of the poloidal flux, which might imply classical stability, in agreement with the decay of the mode when the neoclassical drive is removed.« less

  5. A Study of Discharge Coefficient in Bileaflet Valves

    DTIC Science & Technology

    2001-10-25

    Granados J. Garcia MA. Luque I. Concha M. “Conservative operation for mitral stenosis with densely fibrosed or partially calcified valves. An eight...for aortic valves, whereas a lower value (around 0.7) has been proposed for valves mounted in the mitralic position, on account of the larger upstream...section; in the mitral position, then, a valve will have a smaller discharge coefficient (or Aeff/A ratio) than in the aortic position. Using dC =1

  6. Male hamster preference for odors of female hamster vaginal discharges: studies of experiential and hormonal determinants.

    PubMed

    Gregory, E; Engel, K; Pfaff, D

    1975-07-01

    Male hamsters approach sources of odors from female hamster vaginal discharges and spend significantly more time around these odor sources than around control locations in the test box. This preference for female hamster vaginal odors appears in sexually inexperienced as well as experienced males, even in individuals isolated from females since the time of weaning. Castration significantly reduces the sex odor preference, and treatment with testosterone propionate partially restores it.

  7. Particulate and aerosol detector

    NASA Technical Reports Server (NTRS)

    Wortman, J. J.; Donovan, R. P.; Brooks, A. D.; Monteith, L. K.; Kinard, W. H.; Oneil, R. L. (Inventor)

    1976-01-01

    A device is described for counting aerosols and sorting them according to either size, mass or energy. The component parts are an accelerator, a capacitor sensor and a readout. The accelerator is a means for accelerating the aerosols toward the face of the capacitor sensor with such force that they partially penetrate the capacitor sensor, momentarily discharging it. The readout device is a means for counting the number of discharges of the capacitor sensor and measuring the amplitudes of these different discharges. The aerosols are accelerated by the accelerator in the direction of the metal layer with such force that they penetrate the metal and damage the oxide layers, thereby allowing the electrical charge on the capacitor to discharge through the damaged region. Each incident aerosol initiates a discharge path through the capacitor in such a fashion as to vaporize the conducting path. Once the discharge action is complete, the low resistance path no longer exists between the two capacitor plates and the capacitor is again able to accept a charge. The active area of the capacitor is reduced in size by the damaged area each time a discharge occurs.

  8. Improvement in low-temperature and instantaneous high-rate output performance of Al-free AB5-type hydrogen storage alloy for negative electrode in Ni/MH battery: Effect of thermodynamic and kinetic regulation via partial Mn substituting

    NASA Astrophysics Data System (ADS)

    Zhou, Wanhai; Zhu, Ding; Tang, Zhengyao; Wu, Chaoling; Huang, Liwu; Ma, Zhewen; Chen, Yungui

    2017-03-01

    A series of Al-free Mn-modified AB5-type hydrogen storage alloys have been designed and the effects of thermodynamic stability and electrochemical kinetics on electrochemical performance via Mn substituting have been investigated. Compared with high-Al alloys, the Al-free alloys in this study have better low-temperature performance and instantaneous high-rate output because of the higher surface catalytic ability. After partial substitution of Ni by Mn, both the hydrogen desorption capacity and plateau pressure decrease, and correspondingly results in an improved thermodynamic stability which is adverse to low-temperature delivery. Additionally, with the improvement of charge acceptance ability and anti-corrosion property via Mn substitution, the room-temperature discharge capacity and cycling stability increase slightly. However, Mn adversely affects the electrochemical kinetics and deteriorates both the surface catalytic ability and the bulk hydrogen diffusion ability, leading to the drop of low-temperature dischargeability, high-rate dischargeability and peak power (Ppeak). Based on the thermodynamic and kinetic regulation and overall electrochemical properties, the optimal composition is obtained when x = 0.2, the discharge capacity is 243.6 mAh g-1 at -40 °C with 60 mA g-1, and the Ppeak attains to 969.6 W kg-1 at -40 °C.

  9. Partial discharge detection and analysis in low pressure environments

    NASA Astrophysics Data System (ADS)

    Liu, Xin

    Typical aerospace vehicles (aircraft and spacecraft) experience a wide range of operating pressures during ascending and returning to earth. Compared to the sea-level atmospheric pressure (760 Torr), the pressure at about 60 km altitude is 2 Torr. The performance of the electric power system components of the aerospace vehicles must remain reliable even under such sub-atmospheric operating conditions. It is well known that the dielectric strength of gaseous insulators, while the electrode arrangement remains unchanged, is pressure dependent. Therefore, characterization of the performance and behavior of the electrical insulation in flight vehicles in low-pressure environments is extremely important. Partial discharge testing is one of the practical methods for evaluating the integrity of electrical insulation in aerospace vehicles. This dissertation describes partial discharge (PD) measurements performed mainly with 60 Hz ac energization in air, argon and helium, for pressures between 2 and 760 Torr. Two main electrode arrangements were used. One was a needle-plane electrode arrangement with a Teflon insulating barrier. The other one was a twisted pair of insulated conductors taken from a standard aircraft wiring harness. The measurement results are presented in terms of typical PD current pulse waveforms and waveform analysis for both main electrode arrangements. The evaluation criteria are the waveform polarity, magnitude, shape, rise time, and phase angle (temporal location) relative to the source voltage. Two-variable histograms and statistical averages of the PD parameters are presented. The PD physical mechanisms are analyzed. For PD pattern recognition, both statistical methods (such as discharge parameter dot pattern representation, discharge parameter phase distribution, statistical operator calculations, and PD fingerprint development) and wavelet transform applications are investigated. The main conclusions of the dissertation include: (1) The PD current pulse waveforms are dependent on the pressure. (2) The rise time of the waveform is another effective PD current pulse characteristic indicator. (3) PD fingerprint patterns that are already available for atmospheric pressure (760 Torr) conditions are inadequate for the evaluation of PD pulses at low pressures. (4) Various wavelet transform techniques can be used effectively for PD pulse signal denoising purposes, and for PD pulse waveform transient feature recognition.

  10. Statistical analysis of long-term hydrologic records for selection of drought-monitoring sites on Long Island, New York

    USGS Publications Warehouse

    Busciolano, Ronald J.

    2005-01-01

    Ground water is the sole source of water supply for more than 3 million people on Long Island, New York. Large-scale ground-water pumpage, sewering systems, and prolonged periods of below-normal precipitation have lowered ground-water levels and decreased stream-discharge in western and central Long Island. No method is currently (2004) available on Long Island that can assess data from the ground-water-monitoring network to enable water managers and suppliers with the ability to give timely warning of severe water-level declines.This report (1) quantifies past drought- and human-induced changes in the ground-water system underlying Long Island by applying statistical and graphical methods to precipitation, stream-discharge, and ground-water-level data from selected monitoring sites; (2) evaluates the relation between water levels in the upper glacial aquifer and those in the underlying Magothy aquifer; (3) defines trends in stream discharge and ground-water levels that might indicate the onset of drought conditions or the effects of excessive pumping; and (4) discusses the long-term records that were used to select sites for a Long Island drought-monitoring network.Long Island’s long-term hydrologic records indicated that the available data provide a basis for development of a drought-monitoring network. The data from 36 stations that were selected as possible drought-monitoring sites—8 precipitation-monitoring stations, 8 streamflow-gaging (discharge) stations, 15 monitoring wells screened in the upper glacial aquifer under water-table (unconfined) conditions, and 5 monitoring wells screened in the underlying Magothy aquifer under semi-confined conditions—indicate that water levels in western parts of Long Island have fallen and risen markedly (more than 15 ft) in response to fluctuations in pumpage, and have declined from the increased use of sanitary- and storm-sewer systems. Water levels in the central and eastern parts, in contrast, remain relatively unaffected compared to the western parts, although the effects of human activity are discernible in the records.The value of each site as a drought-monitoring indicator was assessed through an analysis of trends in the records. Fifty-year annual and monthly data sets were created and combined into three composite-average hydrographs—precipitation, stream discharge, and ground-water levels. Three zones representing the range of human effect on ground-water levels were delineated to help evaluate islandwide hydrologic conditions and to quantify the indices. Data from the three indices can be used to assess current conditions in the ground-water system underlying Long Island and evaluate water-level declines during periods of drought.

  11. Evaluation of radiocaesium wash-off by soil erosion from various land uses using USLE plots.

    PubMed

    Yoshimura, Kazuya; Onda, Yuichi; Kato, Hiroaki

    2015-01-01

    Radiocaesium wash-off associated with soil erosion in different land use was monitored using USLE plots in Kawamata, Fukushima Prefecture, Japan after the Fukushima Dai-ichi Nuclear Power Plant accident. Parameters and factors relating to soil erosion and (137)Cs concentration in the eroded soil were evaluated based on the field monitoring and presented. The erosion of fine soil, which is defined as the fraction of soil overflowed along with discharged water from a sediment-trap tank, constituted a large proportion of the discharged radiocaesium. This indicated that the quantitative monitoring of fine soil erosion is greatly important for the accurate evaluation of radiocaesium wash-off. An exponential relationship was found between vegetation cover and the amount of eroded soil. Moreover, the radiocaesium concentrations in the discharged soil were greatly affected by the land use. These results indicate that radiocaesium wash-off related to vegetation cover and land use is crucially important in modelling radiocaesium migration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Characteristic of leachate at Alor Pongsu Landfill Site, Perak, Malaysia: A comparative study

    NASA Astrophysics Data System (ADS)

    Nor Farhana Zakaria, Siti; Aziz, Hamidi Abdul

    2018-04-01

    Leachate is a harmful by product generated from the landfill site. Leachate contains a high concentration of pollutant which can cause serious pollution to environmental. In this study, characteristics of leachate in Alor Pongsu Landfill Site (APLS) were monitored and analyzed according to the Standard Methods for the Examination of Water and Wastewater (2005). Composition in leachate at APLS was monitored for one year starting from January 2015 until January 2016. Nine parameters were monitored including color, chemical oxygen demand (COD), biological oxygen demand (BOD5), ammoniacal nitrogen (NH3-N), biodegradability ratio (BOD5/COD), temperature, dissolved oxygen (DO), total dissolved solid (TDS) and pH. Based on the analysis, Alor Pongsu Landfill leachate was categorized as stabilized landfill leachate by referring to the BOD5/COD < 0.1. Comparison with allowable discharge limits for leachate shows that most of parameters exceeded the standard discharge limitation. Thus, proper treatment is needed before leachate can be discharged to the environment.

  13. Benchmarking of hospital information systems: Monitoring of discharge letters and scheduling can reveal heterogeneities and time trends

    PubMed Central

    Dugas, Martin; Eckholt, Markus; Bunzemeier, Holger

    2008-01-01

    Background Monitoring of hospital information system (HIS) usage can provide insights into best practices within a hospital and help to assess time trends. In terms of effort and cost of benchmarking, figures derived automatically from the routine HIS system are preferable to manual methods like surveys, in particular for repeated analysis. Methods Due to relevance for quality management and efficient resource utilization we focused on time-to-completion of discharge letters (assessed by CT-plots) and usage of patient scheduling. We analyzed these parameters monthly during one year at a major university hospital in Germany. Results We found several distinct patterns of discharge letter documentation indicating a large heterogeneity of HIS usage between different specialties (completeness 51 – 99%, delays 0 – 90 days). Overall usage of scheduling increased during the observation period by 62%, but again showed a considerable variation between departments. Conclusion Regular monitoring of HIS key figures can contribute to a continuous HIS improvement process. PMID:18423046

  14. Time-variation of hydrothermal discharge at selected sites in the Western United States: Implications for monitoring

    USGS Publications Warehouse

    Ingebritsen, S.E.; Galloway, D.L.; Colvard, E.M.; Sorey, M.L.; Mariner, R.H.

    2001-01-01

    We compiled time series of hydrothermal discharge consisting of 3593 chloride- or heat-flux measurements from 24 sites in the Yellowstone region, the northern Oregon Cascades, Lassen Volcanic National Park and vicinity, and Long Valley, California. At all of these sites the hydrothermal phenomena are believed to be as yet unaffected by human activity, though much of the data collection was driven by mandates to collect environmental-baseline data in acticipation of geothermal development. The time series average 19 years in length and some of the Yellowstone sites have been monitored intermittently for over 30 years. Many sites show strong seasonality but few show clear long-term trends, and at most sites statistically significant decadal-scale trends are absent. Thus, the data provide robust estimates of advective heat flow ranging from ~130 MW in the north-central Oregon Cascades to ~6100 MW in the Yellowstone region, and also document Yellowstone hydrothermal chloride and arsenic fluxes of 1740 and 15-20 g/s, respectively. The discharge time series show little sensitivity to regional tectonic events such as earthquakes or inflation/deflation cycles. Most long-term monitoring to date has focused on high-chloride springs and low-temperature fumaroles. The relative stability of these features suggests that discharge measurements done as part of volcano-monitoring programs should focus instead on high-temperature fumaroles, which may be more immediately linked to the magmatic heat source. ?? 2001 Elsevier Science B.V. All rights reserved.

  15. 40 CFR 60.175 - Monitoring of operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Zinc... monitor and record the opacity of gases discharged into the atmosphere from any sintering machine. The... volume. (i) The continuous monitoring system performance evaluation required under § 60.13(c) shall be...

  16. Effect of catalysts on dc corona discharge poisoning

    NASA Astrophysics Data System (ADS)

    Pekárek, S.

    2011-02-01

    The processes of ozone generation in non-thermal plasma produced by an electrical discharge in air at atmospheric pressure are burdened by the presence of nitrogen oxides, which on the one hand contribute to ozone generation and on the other hand are responsible for unpleasant discharge poisoning. The term discharge poisoning refers to the situation when the discharge ozone formation completely breaks down. Discharge poisoning can be affected by placing a catalyst in the discharge chamber. For the dc hollow needle to mesh corona discharge enhanced by the flow of air through the needle electrode we studied the effect of titanium dioxide TiO2, ZSM-5 zeolite or Cu++ZSM-5 zeolite on discharge poisoning by monitoring the ozone, nitrogen monoxide and nitrogen dioxide discharge production. We found that placing globules of any of these catalysts on the mesh decreases the energy density of the onset of discharge poisoning, and this energy density is smallest for a discharge with globules of a TiO2 on the mesh.

  17. Utilising monitoring and modelling of estuarine environments to investigate catchment conditions responsible for stratification events in a typically well-mixed urbanised estuary

    NASA Astrophysics Data System (ADS)

    Lee, Serena B.; Birch, Gavin F.

    2012-10-01

    Estuarine health is affected by contamination from stormwater, particularly in highly-urbanised environments. For systems where catchment monitoring is insufficient, novel techniques must be employed to determine the impact of urban runoff on receiving water bodies. In the present work, estuarine monitoring and modelling were successfully employed to determine stormwater runoff volumes and establish an appropriate rainfall/runoff relationship capable of replicating fresh-water discharge due to the full range of precipitation conditions in the Sydney Estuary, Australia. Using estuary response to determine relationships between catchment rainfall and runoff is a widely applicable method and may be of assistance in the study of waterways where monitoring fluvial discharges is not practical or is beyond the capacity of management authorities. For the Sydney Estuary, the SCS-CN method replicated rainfall/runoff and was applied in numerical modelling experiments investigating the hydrodynamic characteristics affecting stratification and estuary recovery following high precipitation. Numerical modelling showed stratification in the Sydney Estuary was dominated by fresh-water discharge. Spring tides and up-estuary winds contributed to mixing and neap tides and down-estuary winds enhanced stratification.

  18. 40 CFR 433.12 - Monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... indirect dischargers, the control authority) may allow dischargers to make the following certification... the permit limitation [or pretreatment standard] for total toxic organics (TTO), I certify that, to the best of my knowledge and belief, no dumping of concentrated toxic organics into the wastewaters...

  19. Method and apparatus for monitoring oxygen partial pressure in air masks

    NASA Technical Reports Server (NTRS)

    Kelly, Mark E. (Inventor); Pettit, Donald R. (Inventor)

    2006-01-01

    Method and apparatus are disclosed for monitoring an oxygen partial pressure in an air mask and providing a tactile warning to the user. The oxygen partial pressure in the air mask is detected using an electrochemical sensor, the output signal from which is provided to a comparator. The comparator compares the output signal with a preset reference value or range of values representing acceptable oxygen partial pressures. If the output signal is different than the reference value or outside the range of values, the air mask is vibrated by a vibrating motor to alert the user to a potentially hypoxic condition.

  20. The study of excited oxygen molecule gas species production and quenching on thermal protection system materials

    NASA Technical Reports Server (NTRS)

    Nordine, Paul C.; Fujimoto, Gordon T.; Greene, Frank T.

    1987-01-01

    The detection of excited oxygen and ozone molecules formed by surface catalyzed oxygen atom recombination and reaction was investigated by laser induced fluorescence (LIF), molecular beam mass spectrometric (MBMS), and field ionization (FI) techniques. The experiment used partially dissociated oxygen flows from a microwave discharge at pressures in the range from 60 to 400 Pa or from an inductively coupled RF discharge at atmospheric pressure. The catalyst materials investigated were nickel and the reaction cured glass coating used for Space Shuttle reusable surface insulation tiles. Nonradiative loss processes for the laser excited states makes LIF detection of O2 difficult such that formation of excited oxygen molecules could not be detected in the flow from the microwave discharge or in the gaseous products of atom loss on nickel. MBMS experiments showed that ozone was a product of heterogeneous O atom loss on nickel and tile surfaces at low temperatures and that ozone is lost on these materials at elevated temperatures. FI was separately investigated as a method by which excited oxygen molecules may be conveniently detected. Partial O2 dissociation decreases the current produced by FI of the gas.

  1. Dielectric gas mixtures containing sulfur hexafluoride

    DOEpatents

    Cooke, Chathan M.

    1979-01-01

    Electrically insulating gaseous media of unexpectedly high dielectric strength comprised of mixtures of two or more dielectric gases are disclosed wherein the dielectric strength of at least one gas in each mixture increases at less than a linear rate with increasing pressure and the mixture gases are present in such proportions that the sum of their electrical discharge voltages at their respective partial pressures exceeds the electrical discharge voltage of each individual gas at the same temperature and pressure as that of the mixture.

  2. Laser-driven acceleration of electrons in a partially ionized plasma channel.

    PubMed

    Rowlands-Rees, T P; Kamperidis, C; Kneip, S; Gonsalves, A J; Mangles, S P D; Gallacher, J G; Brunetti, E; Ibbotson, T; Murphy, C D; Foster, P S; Streeter, M J V; Budde, F; Norreys, P A; Jaroszynski, D A; Krushelnick, K; Najmudin, Z; Hooker, S M

    2008-03-14

    The generation of quasimonoenergetic electron beams, with energies up to 200 MeV, by a laser-plasma accelerator driven in a hydrogen-filled capillary discharge waveguide is investigated. Injection and acceleration of electrons is found to depend sensitively on the delay between the onset of the discharge current and the arrival of the laser pulse. A comparison of spectroscopic and interferometric measurements suggests that injection is assisted by laser ionization of atoms or ions within the channel.

  3. A Two-Year Water Quality Monitoring Curriculum.

    ERIC Educational Resources Information Center

    Glazer, Richard B.; And Others

    The Environmental Protection Agency developed this curriculum to train technicians to monitor water quality. Graduates of the program should be able to monitor municipal, industrial, and commercial discharges; test drinking water for purity; and determine quality of aquatic environments. The program includes algebra, communication skills, biology,…

  4. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Monitoring devices. 154.525...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154.525...

  5. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Monitoring devices. 154.525...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154.525...

  6. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Monitoring devices. 154.525...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154.525...

  7. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Monitoring devices. 154.525...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154.525...

  8. The probability of seizures during EEG monitoring in critically ill adults.

    PubMed

    Westover, M Brandon; Shafi, Mouhsin M; Bianchi, Matt T; Moura, Lidia M V R; O'Rourke, Deirdre; Rosenthal, Eric S; Chu, Catherine J; Donovan, Samantha; Hoch, Daniel B; Kilbride, Ronan D; Cole, Andrew J; Cash, Sydney S

    2015-03-01

    To characterize the risk for seizures over time in relation to EEG findings in hospitalized adults undergoing continuous EEG monitoring (cEEG). Retrospective analysis of cEEG data and medical records from 625 consecutive adult inpatients monitored at a tertiary medical center. Using survival analysis methods, we estimated the time-dependent probability that a seizure will occur within the next 72-h, if no seizure has occurred yet, as a function of EEG abnormalities detected so far. Seizures occurred in 27% (168/625). The first seizure occurred early (<30min of monitoring) in 58% (98/168). In 527 patients without early seizures, 159 (30%) had early epileptiform abnormalities, versus 368 (70%) without. Seizures were eventually detected in 25% of patients with early epileptiform discharges, versus 8% without early discharges. The 72-h risk of seizures declined below 5% if no epileptiform abnormalities were present in the first two hours, whereas 16h of monitoring were required when epileptiform discharges were present. 20% (74/388) of patients without early epileptiform abnormalities later developed them; 23% (17/74) of these ultimately had seizures. Only 4% (12/294) experienced a seizure without preceding epileptiform abnormalities. Seizure risk in acute neurological illness decays rapidly, at a rate dependent on abnormalities detected early during monitoring. This study demonstrates that substantial risk stratification is possible based on early EEG abnormalities. These findings have implications for patient-specific determination of the required duration of cEEG monitoring in hospitalized patients. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  9. Self-stabilized discharge filament in plane-parallel barrier discharge configuration: formation, breakdown mechanism, and memory effects

    NASA Astrophysics Data System (ADS)

    Tschiersch, R.; Nemschokmichal, S.; Bogaczyk, M.; Meichsner, J.

    2017-10-01

    Single self-stabilized discharge filaments were investigated in the plane-parallel electrode configuration. The barrier discharge was operated inside a gap of 3 mm shielded by glass plates to both electrodes, using helium-nitrogen mixtures and a square-wave feeding voltage at a frequency of 2 kHz. The combined application of electrical measurements, ICCD camera imaging, optical emission spectroscopy and surface charge diagnostics via the electro-optic Pockels effect allowed the correlation of the discharge development in the volume and on the dielectric surfaces. The formation criteria and existence regimes were found by systematic variation of the nitrogen admixture to helium, the total pressure and the feeding voltage amplitude. Single self-stabilized discharge filaments can be operated over a wide parameter range, foremost, by significant reduction of the voltage amplitude after the operation in the microdischarge regime. Here, the outstanding importance of the surface charge memory effect on the long-term stability was pointed out by the recalculated spatio-temporally resolved gap voltage. The optical emission revealed discharge characteristics that are partially reminiscent of both the glow-like barrier discharge and the microdischarge regime, such as a Townsend pre-phase, a fast cathode-directed ionization front during the breakdown and radially propagating surface discharges during the afterglow.

  10. 33 CFR 157.12b - Implementation requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... OIL IN BULK Design, Equipment, and Installation § 157.12b Implementation requirements. Oil discharge monitoring and control systems must be fitted to oil tankers to which this subpart applies. A monitoring and...

  11. 33 CFR 157.12b - Implementation requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... OIL IN BULK Design, Equipment, and Installation § 157.12b Implementation requirements. Oil discharge monitoring and control systems must be fitted to oil tankers to which this subpart applies. A monitoring and...

  12. 33 CFR 157.12b - Implementation requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... OIL IN BULK Design, Equipment, and Installation § 157.12b Implementation requirements. Oil discharge monitoring and control systems must be fitted to oil tankers to which this subpart applies. A monitoring and...

  13. 33 CFR 157.12b - Implementation requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OIL IN BULK Design, Equipment, and Installation § 157.12b Implementation requirements. Oil discharge monitoring and control systems must be fitted to oil tankers to which this subpart applies. A monitoring and...

  14. 33 CFR 157.12b - Implementation requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... OIL IN BULK Design, Equipment, and Installation § 157.12b Implementation requirements. Oil discharge monitoring and control systems must be fitted to oil tankers to which this subpart applies. A monitoring and...

  15. Novel Physical Model for DC Partial Discharge in Polymeric Insulators

    NASA Astrophysics Data System (ADS)

    Andersen, Allen; Dennison, J. R.

    The physics of DC partial discharge (DCPD) continues to pose a challenge to researchers. We present a new physically-motivated model of DCPD in amorphous polymers based on our dual-defect model of dielectric breakdown. The dual-defect model is an extension of standard static mean field theories, such as the Crine model, that describe avalanche breakdown of charge carriers trapped on uniformly distributed defect sites. It assumes the presence of both high-energy chemical defects and low-energy thermally-recoverable physical defects. We present our measurements of breakdown and DCPD for several common polymeric materials in the context of this model. Improved understanding of DCPD and how it relates to eventual dielectric breakdown is critical to the fields of spacecraft charging, high voltage DC power distribution, high density capacitors, and microelectronics. This work was supported by a NASA Space Technology Research Fellowship.

  16. Two-wavelength quadrature multipoint detection of partial discharge in power transformers using fiber Fabry-Perot acoustic sensors

    NASA Astrophysics Data System (ADS)

    Dong, Bo; Han, Ming; Wang, Anbo

    2012-06-01

    A reliable and low-cost two-wavelength quadrature interrogating method has been developed to demodulate optical signals from diaphragm-based Fabry-Perot interferometric fiber optic sensors for multipoint partial discharge detection in power transformers. Commercial available fused-silica parts (a wafer, a fiber ferrule, and a mating sleeve) and a cleaved optical single mode fiber were bonded together to form an extrinsic Fabry-Perot acoustic sensor. Two lasers with center wavelengths separated by a quarter of the period of sensor interference fringes were used to probe acousticwave- induced diaphragm vibration. A coarse wavelength-division multiplexing (CWDM) add/drop multiplexer was used to separate the reflected two wavelengths before two photo detectors. Optical couplers were used to distribute mixed laser light to each sensor-detector module for multiplexing purpose. Sensor structure, detection system design and experiment results are presented.

  17. Two dimensional radial gas flows in atmospheric pressure plasma-enhanced chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Kim, Gwihyun; Park, Seran; Shin, Hyunsu; Song, Seungho; Oh, Hoon-Jung; Ko, Dae Hong; Choi, Jung-Il; Baik, Seung Jae

    2017-12-01

    Atmospheric pressure (AP) operation of plasma-enhanced chemical vapor deposition (PECVD) is one of promising concepts for high quality and low cost processing. Atmospheric plasma discharge requires narrow gap configuration, which causes an inherent feature of AP PECVD. Two dimensional radial gas flows in AP PECVD induces radial variation of mass-transport and that of substrate temperature. The opposite trend of these variations would be the key consideration in the development of uniform deposition process. Another inherent feature of AP PECVD is confined plasma discharge, from which volume power density concept is derived as a key parameter for the control of deposition rate. We investigated deposition rate as a function of volume power density, gas flux, source gas partial pressure, hydrogen partial pressure, plasma source frequency, and substrate temperature; and derived a design guideline of deposition tool and process development in terms of deposition rate and uniformity.

  18. Water resources data, Ohio, water year 2003 : Volume 1. Ohio River basin excluding project data

    USGS Publications Warehouse

    Shindel, H.L.; Mangus, J.P.; Frum, S.R.

    2004-01-01

    Water-resources data for the 2003 water year for Ohio consist of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground-water wells. This report, in two volumes, contains records for water discharge at 138 gaging stations and various partial-record sites; water levels at 217 observation wells and 35 crest-stage gages; and water quality at 30 gaging stations, 34 observation wells, and no partial-record sites. Also included are data from miscellaneous and synoptic sites. Additional water data were collected at various sites not involved in the systematic data-collection program and are published as miscellaneous measurements and analyses. These data represent that part of the National Water Information System collected by the U.S. Geological Survey and cooperating Federal, State, and local agencies in Ohio.

  19. Water resources data, Ohio, water year 2003: Volume 2. St. Lawrence River basin and statewide project data

    USGS Publications Warehouse

    Shindel, H.L.; Mangus, J.P.; Frum, S.R.

    2004-01-01

    Water-resources data for the 2003 water year for Ohio consist of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground-water wells. This report, in two volumes, contains records for water discharge at 138 gaging stations and various partial-record sites; water levels at 217 observation wells and 35 crest-stage gages; and water quality at 30 gaging stations, 34 observation wells, and no partial-record sites. Also included are data from miscellaneous and synoptic sites. Additional water data were collected at various sites not involved in the systematic data-collection program and are published as miscellaneous measurements and analyses. These data represent that part of the National Water Information System collected by the U.S. Geological Survey and cooperating Federal, State, and local agencies in Ohio.

  20. Water resources data for California, water year 1996. Volume 1. Southern Great Basin from Mexican Border to Mono Lake Basin and Pacific Slope basins from Tijuana River to Santa Maria river. Water-data report (Annual), 1 October 1995-30 September 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rockwell, G.L.; Hayes, P.D.; Agajanian, J.

    1997-07-01

    Water-resources data for the 1996 water year for California consist of records of stage, discharge, and water quality of streams, stage and contents in lakes and reservoirs, and water levels and water quality in wells. Volume 1 contains discharge records for 149 gaging stations and 6 crest-stage partial-record stations, stage and contents for 21 lakes and reservoirs, gage height records for 1 station, water quality for 19 streamflow-gaging stations and 17 partial-record stations, and precipitation data for 4 stations. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State andmore » Federal agencies in California.« less

  1. Correlational Study of Sleep Apnea Patient Characteristics With Discharge Locations.

    PubMed

    Lee, Esther; Daugherty, JoAnn; Burkard, Joseph

    2016-10-01

    To determine if a correlation exists between OSA patient characteristics and the PACU discharge location; and the characteristics of the patients at-risk for low saturation levels, increased number of desaturations, and longer length of stay in the PACU. Retrospective, correlational study design. Chart review of OSA patients ≥ 18 years old. Correlational analysis was performed between 15 high risk patient variables and the PACU discharge disposition: home or monitored bed. Complications resulting in monitored bed admission were reviewed. 153 patients' charts were reviewed. The results showed that age>60, ASA classification, anesthesia type and narcotics use in the PACU were significantly correlated (p≤.05) with a patient's discharge disposition. The findings are consistent with other OSA research except BMI was not significant in this study. The results highlighted areas for future research and implications for clinical practice that would enable the perioperative care team to deliver safe care based on evidence. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  2. A framework to determine the locations of the environmental monitoring in an estuary of the Yellow Sea.

    PubMed

    Kim, Nam-Hoon; Hwang, Jin Hwan; Cho, Jaegab; Kim, Jae Seong

    2018-06-04

    The characteristics of an estuary are determined by various factors as like as tide, wave, river discharge, etc. which also control the water quality of the estuary. Therefore, detecting the changes of characteristics is critical in managing the environmental qualities and pollution and so the locations of monitoring should be selected carefully. The present study proposes a framework to deploy the monitoring systems based on a graphical method of the spatial and temporal optimizations. With the well-validated numerical simulation results, the monitoring locations are determined to capture the changes of water qualities and pollutants depending on the variations of tide, current and freshwater discharge. The deployment strategy to find the appropriate monitoring locations is designed with the constrained optimization method, which finds solutions by constraining the objective function into the feasible regions. The objective and constrained functions are constructed with the interpolation technique such as objective analysis. Even with the smaller number of the monitoring locations, the present method performs well equivalently to the arbitrarily and evenly deployed monitoring system. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. A New Method for Suppressing Periodic Narrowband Interference Based on the Chaotic van der Pol Oscillator

    NASA Astrophysics Data System (ADS)

    Lu, Jia; Zhang, Xiaoxing; Xiong, Hao

    The chaotic van der Pol oscillator is a powerful tool for detecting defects in electric systems by using online partial discharge (PD) monitoring. This paper focuses on realizing weak PD signal detection in the strong periodic narrowband interference by using high sensitivity to the periodic narrowband interference signals and immunity to white noise and PD signals of chaotic systems. A new approach to removing the periodic narrowband interference by using a van der Pol chaotic oscillator is described by analyzing the motion characteristic of the chaotic oscillator on the basis of the van der Pol equation. Furthermore, the Floquet index for measuring the amplitude of periodic narrowband signals is redefined. The denoising signal processed by the chaotic van der Pol oscillators is further processed by wavelet analysis. Finally, the denoising results verify that the periodic narrowband and white noise interference can be removed efficiently by combining the theory of the chaotic van der Pol oscillator and wavelet analysis.

  4. Incipient fault diagnosis of power transformers using optical spectro-photometric technique

    NASA Astrophysics Data System (ADS)

    Hussain, K.; Karmakar, Subrata

    2015-06-01

    Power transformers are the vital equipment in the network of power generation, transmission and distribution. Mineral oil in oil-filled transformers plays very important role as far as electrical insulation for the winding and cooling of the transformer is concerned. As transformers are always under the influence of electrical and thermal stresses, incipient faults like partial discharge, sparking and arcing take place. As a result, mineral oil deteriorates there by premature failure of the transformer occurs causing huge losses in terms of revenue and assets. Therefore, the transformer health condition has to be monitored continuously. The Dissolved Gas Analysis (DGA) is being extensively used for this purpose, but it has some drawbacks like it needs carrier gas, regular instrument calibration, etc. To overcome these drawbacks, Ultraviolet (UV) -Visible and Fourier Transform Infrared (FTIR) Spectro-photometric techniques are used as diagnostic tools for investigating the degraded transformer oil affected by electrical, mechanical and thermal stresses. The technique has several advantages over the conventional DGA technique.

  5. Palilalia, echolalia, and echopraxia-palipraxia as ictal manifestations in a patient with left frontal lobe epilepsy.

    PubMed

    Cho, Yang-Je; Han, Sang-Don; Song, Sook Keun; Lee, Byung In; Heo, Kyoung

    2009-06-01

    Palilalia is a relatively rare pathologic speech behavior and has been reported in various neurologic and psychiatric disorders. We encountered a case of palilalia, echolalia, and echopraxia-palipraxia as ictal phenomena of left frontal lobe epilepsy. A 55-year-old, right-handed man was admitted because of frequent episodes of rapid reiteration of syllables. Video-electroencephalography monitoring revealed stereotypical episodes of palilalia accompanied by rhythmic head nodding and right-arm posturing with ictal discharges over the left frontocentral area. He also displayed echolalia or echopraxia-palipraxia, partially responding to an examiner's stimulus. Magnetic resonance imaging revealed encephalomalacia on the left superior frontal gyrus and ictal single photon emission computed tomography showed hyperperfusion just above the lesion, corresponding to the left supplementary motor area (SMA), and subcortical nuclei. This result suggests that the neuroanatomic substrate involved in the generation of these behaviors as ictal phenomena might exist in the SMA of the left frontal lobe.

  6. Quality Indicators for Human Milk Use in Very Low Birthweight Infants: Are We Measuring What We Should be Measuring?

    PubMed Central

    Bigger, Harold R.; Fogg, Louis J.; Patel, Aloka; Johnson, Tricia; Engstrom, Janet L.; Meier, Paula P.

    2014-01-01

    Objective The objective of this study was to compare the currently used human milk (HM) quality indicators that measure whether very low birthweight (VLBW; <1500 g birthweight) infants “ever” received HM and whether they were still receiving HM at discharge from the neonatal intensive care unit (NICU) to the actual amount and timing of HM received. Study Design This study used data from a large NIH-funded cohort study and calculated whether VLBW infants ever received HM (HM-Ever) and of these infants, the percentage who were still receiving HM at NICU discharge (HM-DC). Then, the HM-DC indicator (exclusive, partial and none) was compared with the amount and timing of HM feedings received by these same infants. Results Of the 291 VLBW infants who met inclusion criteria, 285 received some HM (HM-Ever = 98%). At NICU discharge (HM-DC), 24.2%, 15.1% and 60.7% were receiving exclusive, partial and no HM, respectively. Of the 60.7% infants with no HM-DC, some had received higher amounts of HM during the NICU hospitalization than infants categorized as exclusive and partial for HM-DC. Of the infants with no HM-DC, 76.8% and 59.7% had received exclusive HM during the Days 1–14 and Days 1–28 exposure periods, respectively. Conclusion The average daily dose (HM-DD; in mL/kg/d) and cumulative percentage (HM-PCT; as % of cumulative enteral intake) of HM feedings were sufficient to significantly reduce the risk of multiple morbidities, including late onset sepsis, necrotizing enterocolitis, neurocognitive delay and rehospitalization, in the majority of the VLBW infants who were discharged with no HM-DC. Quality indicators that focus on the amount and timing of HM feedings in the NICU should be added to the HM-Ever and HM-DC measures. PMID:24526005

  7. Arctic River Discharge and Sediment Loads --- an Overview

    NASA Astrophysics Data System (ADS)

    Syvitski, J. P.; Overeem, I.; Brakenridge, G. R.; Hudson, B.; Cohen, S.

    2014-12-01

    Evidence suggests that river discharge has been increasing (+10%) over the last 30 years (1977-2007) for most arctic rivers. The peak melt month occurs earlier in the season in 66% of the studied rivers. Cold season flow is also increasing. Satellite discharge estimates, daily, based on microwave radiometry, are now possible from 1998 onwards. Daily river discharge hindcasts over the last 60 years using the water balance model WBMsed at a 10km spatial resolution are now available. The WBMsed model can be used in forecast mode assuming valid input climatology. The challenge here has been the accuracy of sub-polar precipitation grids. While each of these three methods (gauging, orbital sensing, modeling) has temporal and spatial coverage limitations, the combination of all three methods provides for a realistic way forward for estimating local discharge across the pan arctic. Flood inundation products are routinely produced for the pan-arctic using automated mapping algorithms developed by the Dartmouth Flood Observatory. The determination of artic river sediment loads is less than ideal. Some rivers have only been monitored for a short number of years, and many have not been monitored at all. The WBMsed model is perhaps the best method of estimating the daily sediment flux to the Arctic Ocean, at least for rivers where the mean discharge is greater than 30 m3/s. Additionally there is limited-duration field monitoring by national surveys. New methods are being explored, including back calculating the delivery of sediment to the coastal ocean by plume dimensions observed from space (MODIS, LandSat). These methods have had moderate success when applied to plumes extending in the Greenland fjords. Canada maintains an active circa 7-y satellite program (ArcticNet) to track the Mackenzie discharge during the spring-summer runoff period when turbid river water is apt to flow under and over marginal sea ice in the Beaufort Sea.

  8. Near real-time analysis of tritium in treated water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skibo, A.

    The Tokyo Electric Power Company (TEPCO) is managing large quantities of treated water at the Fukushima Daiichi Nuclear Power Station. Moving forward, TEPCO will be discharging from the site clean water that meets agreed criteria. As part of agreements with stakeholders, TEPCO is planning to carefully monitor the water prior to discharge to assure compliance. The objective of this proposal is to support implementation of an on-line “real-time” (continuous or semi-continuous) tritium monitor that will reliably measure levels down to the agreed target 1500 Becquerels per liter (Bq/L).

  9. Plasma polymerization of ethylene in an atmospheric pressure-pulsed discharge

    NASA Technical Reports Server (NTRS)

    Donohoe, K.; Wydeven, T.

    1979-01-01

    The polymerization of ethylene in an atmospheric pressure-pulsed discharge has been studied. Partial pressures of ethylene up to 4 kN/sq m were used with helium as a diluent. Deposition rates (on glass slides) were the same throughout the discharge volume over a wide range of operating conditions. These rates were in the 1-2 A/sec range. The films were clear, soft, and showed good adhesion to the glass substrates. Oligomers large enough to visibly scatter 637.8-nm light were observed in the gas phase under all conditions in which film deposition occurred. The experimental results suggest that Brownian diffusion of these oligomers was the rate-limiting step in the film deposition process.

  10. Boundary-value problem for a counterrotating electrical discharge in an axial magnetic field. [plasma centrifuge for isotope separation

    NASA Technical Reports Server (NTRS)

    Hong, S. H.; Wilhelm, H. E.

    1978-01-01

    An electrical discharge between two ring electrodes embedded in the mantle of a cylindrical chamber is considered, in which the plasma in the anode and cathode regions rotates in opposite directions under the influence of an external axial magnetic field. The associated boundary-value problem for the coupled partial differential equations describing the azimuthal velocity and radial current-density fields is solved in closed form. The velocity, current density, induced magnetic induction, and electric fields are presented for typical Hartmann numbers, magnetic Reynolds numbers, and geometry parameters. The discharge is shown to produce anodic and cathodic plasma sections rotating at speeds of the order 1,000,000 cm/sec for conventional magnetic field intensities. Possible application of the magnetoactive discharge as a plasma centrifuge for isotope separation is discussed.

  11. 40 CFR 75.5 - Prohibitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (c) No owner or operator of an affected unit shall use any alternative monitoring system, alternative... be discharged, emissions of SO2, NOX or CO2 to the atmosphere without accounting for all such... approved emission monitoring method, and thereby avoid monitoring and recording SO2, NOX, or CO2 emissions...

  12. 300 area TEDF NPDES Permit Compliance Monitoring Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loll, C.M.

    1995-09-05

    This document presents the 300 Area Treated Effluent Disposal Facility (TEDF) National Pollutant Discharge Elimination System (NPDES) Permit Compliance Monitoring Plan (MP). The MP describes how ongoing monitoring of the TEDF effluent stream for compliance with the NPDES permit will occur. The MP also includes Quality Assurance protocols to be followed.

  13. Peri-ictal water drinking and other ictal vegetative symptoms: Localizing and lateralizing the epileptogenic zone in temporal lobe epilepsy? Two case reports and review of the literature.

    PubMed

    Errguig, L; Lahjouji, F; Belaidi, H; Jiddane, M; Elkhamlichi, A; Dakka, T; Ouazzani, R

    2013-11-01

    Peri-ictal behavior disorders can be helpful in localizing and lateralizing seizure onset in partial epilepsies, especially those originating in the temporal lobe. In this paper, we present the case of two right-handed women aged 36 and 42 years who presented with partial seizures of mesial temporal type. Both of the patients had drug resistant epilepsy and undergone presurgical evaluation tests including brain magnetic resonance imaging, video-EEG monitoring and neuropsychological testing. The two patients had hippocampal sclerosis in the right temporal lobe and exhibited PIWD behavior concomitant with right temporal lobe discharges documented during video-EEG recordings. Anterior temporal lobectomy was performed in one case with an excellent outcome after surgery. The patient was free of seizures at 3 years follow-up. We reviewed other publications of peri-ictal autonomic symptoms considered to have a lateralizing significance, such as peri-ictal vomiting, urinary urge, ictal pilo-erection. Clinicians should search for these symptoms, even if not spontaneously reported by the patient, because they are often under-estimated, both by the patients themselves and by physicians. Additionally, patients with lateralizing auras during seizures have a significantly better outcome after epilepsy surgery than those without lateralizing features. Copyright © 2013. Published by Elsevier Masson SAS.

  14. 33 CFR 157.12d - Technical specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Design, Equipment, and Installation § 157.12d Technical specifications. (a) Oil discharge monitoring and... effectively under all environmental conditions normally encountered by oil tankers, and must be designed and... must be designed so a discharge of dirty-ballast or other oil-contaminated water from the cargo tank...

  15. 33 CFR 157.12d - Technical specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Design, Equipment, and Installation § 157.12d Technical specifications. (a) Oil discharge monitoring and... effectively under all environmental conditions normally encountered by oil tankers, and must be designed and... must be designed so a discharge of dirty-ballast or other oil-contaminated water from the cargo tank...

  16. Exploring Nontraditional Participation as an Approach to Make Water Quality Trading Markets More Effective

    EPA Science Inventory

    Water quality trading (WQT) under the Clean Water Act is a compliance option for water quality based effluent limitations in a National Pollutant Discharge Elimination System (NPDES) permit (i.e., the requirements for discharging, monitoring, and reporting). States that have enac...

  17. Electrical treeing behaviors in silicone rubber under an impulse voltage considering high temperature

    NASA Astrophysics Data System (ADS)

    Yunxiao, ZHANG; Yuanxiang, ZHOU; Ling, ZHANG; Zhen, LIN; Jie, LIU; Zhongliu, ZHOU

    2018-05-01

    In this paper, work was conducted to reveal electrical tree behaviors (initiation and propagation) of silicone rubber (SIR) under an impulse voltage with high temperature. Impulse frequencies ranging from 10 Hz to 1 kHz were applied and the temperature was controlled between 30 °C and 90 °C. Experimental results show that tree initiation voltage decreases with increasing pulse frequency, and the descending amplitude is different in different frequency bands. As the pulse frequency increases, more frequent partial discharges occur in the channel, increasing the tree growth rate and the final shape intensity. As for temperature, the initiation voltage decreases and the tree shape becomes denser as the temperature gets higher. Based on differential scanning calorimetry results, we believe that partial segment relaxation of SIR at high temperature leads to a decrease in the initiation voltage. However, the tree growth rate decreases with increasing temperature. Carbonization deposition in the channel under high temperature was observed under microscope and proven by Raman analysis. Different tree growth models considering tree channel characteristics are proposed. It is believed that increasing the conductivity in the tree channel restrains the partial discharge, holding back the tree growth at high temperature.

  18. A flowing partially penetrating well in a finite-thickness aquifer: a mixed-type initial boundary value problem

    NASA Astrophysics Data System (ADS)

    Chang, Chien-Chieh; Chen, Chia-Shyun

    2003-02-01

    An analytical approach using integral transform techniques is developed to deal with a well hydraulics model involving a mixed boundary of a flowing partially penetrating well, where constant drawdown is stipulated along the well screen and no-flux condition along the remaining unscreened part. The aquifer is confined of finite thickness. First, the mixed boundary is changed into a homogeneous Neumann boundary by discretizing the well screen into a finite number of segments, each of which at constant drawdown is subject to unknown a priori well bore flux. Then, the Laplace and the finite Fourier transforms are used to solve this modified model. Finally, the prescribed constant drawdown condition is reinstated to uniquely determine the well bore flux function, and to restore the relation between the solution and the original model. The transient and the steady-state solutions for infinite aquifer thickness can be derived from the semi-analytical solution, complementing the currently available dual integral solution. If the distance from the edge of the well screen to the bottom/top of the aquifer is 100 times greater than the well screen length, aquifer thickness can be assumed infinite for times of practical significance, and groundwater flow can reach a steady-state condition, where the well will continuously supply water under a constant discharge. However, if aquifer thickness is smaller, the well discharge decreases with time. The partial penetration effect is most pronounced in the vicinity of the flowing well, decreases with increasing horizontal distance, and vanishes at distances larger than 1-2 times the aquifer thickness divided by the square root of aquifer anisotropy. The horizontal hydraulic conductivity and the specific storage coefficient can be determined from vertically averaged drawdown as measured by fully penetrating observation wells. The vertical hydraulic conductivity can be determined from the well discharge under two particular partial penetration conditions.

  19. Waste-water characterization survey, Whiteman Air Force Base, Missouri. Final report, 28 Oct-7 Nov 91

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fields, M.K.; Davis, R.P.

    1992-08-01

    A wastewater characterization survey was conducted by members of the Armstrong Laboratory Occupational and Environmental Health directorate Water Quality Function from 28 Oct 91 - 7 Nov 91 at Whiteman AFB, MO. The purpose of the survey was to identify and characterize the wastewater, determine the appropriateness of present disposal methods, determine the need for routine sampling or monitoring and recommend parameters for wastewater analysis. Results of the sampling showed metals and volatile organic discharge in varying concentrations throughout the base. Recommendations are: (1) evaluation of industrial operations and chemical disposal procedures at designated sites; (2) routine monitoring of themore » discharge from the Hospital and Audiovisual for silver; (3) excavation and sediment disposal at the Transportation Washrack and WWTP Effluent discharge point; (4) collection and analyses of sludge at oil water separators, to include the oil and water side; (5) evaluation of the sanitary sewer system for corrosion and sediment buildup by a mobile Reveal and Seal Unit; (6) background soil sample collection and analyses; and (7) pretreatment of Aqueous Film Forming Foam discharge and notification of the Base Bioenvironmental Engineer, Environmental Coordinator, and WWTP personnel when discharge occurs.« less

  20. Plasma processes in water under effect of short duration pulse discharges

    NASA Astrophysics Data System (ADS)

    Gurbanov, Elchin

    2013-09-01

    It is very important to get a clear water without any impurities and bacteria by methods, that don't change the physical and chemical indicators of water now. In this article the plasma processes during the water treatment by strong electric fields and short duration pulse discharges are considered. The crown discharge around an electrode with a small radius of curvature consists of plasma leader channels with a high conductivity, where the thermo ionization processes and UV-radiation are taken place. Simultaneously the partial discharges around potential electrode lead to formation of atomic oxygen and ozone. The spark discharge arises, when plasma leader channels cross the all interelectrode gap, where the temperature and pressure are strongly grown. As a result the shock waves and dispersing liquid streams in all discharge gap are formed. The plasma channels extend, pressure inside it becomes less than hydrostatic one and the collapse and UV-radiation processes are started. The considered physical processes can be successfully used as a basis for development of pilot-industrial installations for conditioning of drinking water and to disinfecting of sewage.

  1. 19 CFR 18.6 - Short shipments; shortages; entry and allowance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., in the case of a partial shortage. (d) If merchandise covered by a carnet cannot be recovered intact... and birds found by the discharging officer to be dead on arrival at destination, shall be made in the...

  2. 19 CFR 18.6 - Short shipments; shortages; entry and allowance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., in the case of a partial shortage. (d) If merchandise covered by a carnet cannot be recovered intact... and birds found by the discharging officer to be dead on arrival at destination, shall be made in the...

  3. Factors controlling stream water nitrate and phosphor loads during precipitation events

    NASA Astrophysics Data System (ADS)

    Rozemeijer, J.; van der Velde, Y.; van Geer, F.; de Rooij, G. H.; Broers, H.; Bierkens, M. F.

    2009-12-01

    Pollution of surface waters in densely populated areas with intensive land use is a serious threat to their ecological, industrial and recreational utilization. European and national manure policies and several regional and local pilot projects aim at reducing pollution loads to surface waters. For the evaluation of measures, water authorities and environmental research institutes are putting a lot of effort into monitoring surface water quality. Within regional surface water quality monitoring networks, the measurement locations are usually situated in the downstream part of the catchment to represent a larger area. The monitoring frequency is usually low (e.g. monthly), due to the high costs for sampling and analysis. As a consequence, human induced trends in nutrient loads and concentrations in these monitoring data are often concealed by the large variability of surface water quality caused by meteorological variations. Because this natural variability in surface water quality is poorly understood, large uncertainties occur in the estimates of (trends in) nutrient loads or average concentrations. This study aims at uncertainty reduction in the estimates of mean concentrations and loads of N and P from regional monitoring data. For this purpose, we related continuous records of stream water N and P concentrations to easier and cheaper to collect quantitative data on precipitation, discharge, groundwater level and tube drain discharge. A specially designed multi scale experimental setup was installed in an agricultural lowland catchment in The Netherlands. At the catchment outlet, continuous measurements of water quality and discharge were performed from July 2007-January 2009. At an experimental field within the catchment we collected continuous measurements of precipitation, groundwater levels and tube drain discharges. 20 significant rainfall events with a variety of antecedent conditions, durations and intensities were selected for analysis. Singular and multiple regression analysis were used to identify relations between the N and P response to the rainfall events and the quantitative event characteristics. We successfully used these relations to predict the N and P responses to events and to improve the interpolation between low frequency grab sample measurements. Incorporating the predicted concentration changes during high discharge events dramatically improved the precision of our load estimations.

  4. Plasma rotation by electric and magnetic fields in a discharge cylinder

    NASA Technical Reports Server (NTRS)

    Wilhelm, H. E.; Hong, S. H.

    1977-01-01

    A theoretical model for an electric discharge consisting of a spatially diverging plasma sustained electrically between a small ring cathode and a larger ring anode in a cylindrical chamber with an axial magnetic field is developed to study the rotation of the discharge plasma in the crossed electric and magnetic fields. The associated boundary-value problem for the coupled partial differential equations which describe the electric potential and the plasma velocity fields is solved in closed form. The electric field, current density, and velocity distributions are discussed in terms of the Hartmann number and the Hall coefficient. As a result of Lorentz forces, the plasma rotates with speeds as high as 1 million cm/sec around its axis of symmetry at typical conditions. As an application, it is noted that rotating discharges of this type could be used to develop a high-density plasma-ultracentrifuge driven by j x B forces, in which the lighter (heavier) ion and atom components would be enriched in (off) the center of the discharge cylinder.

  5. Spatio-temporal monitoring of suspended sediments in the Solimões River (2000-2014)

    NASA Astrophysics Data System (ADS)

    Espinoza-Villar, Raul; Martinez, Jean-Michel; Armijos, Elisa; Espinoza, Jhan-Carlo; Filizola, Naziano; Dos Santos, Andre; Willems, Bram; Fraizy, Pascal; Santini, William; Vauchel, Philippe

    2018-01-01

    The Amazon River sediment discharge has been estimated at between 600 and 1200 Mt/year, of which more than 50% comes from the Solimões River. Because of the area's inaccessibility, few studies have examined the sediment discharge spatial and temporal pattern in the upper Solimões region. In this study, we use MODIS satellite images to retrieve and understand the spatial and temporal behaviour of suspended sediments in the Solimões River from Peru to Brazil. Six virtual suspended sediment gauging stations were created along the Solimões River on a 2050-km-long transect. At each station, field-derived river discharge estimates were available and field-sampling trips were conducted for validation of remote-sensing estimates during different periods of the annual hydrological cycle between 2007 and 2014. At two stations, 10-day surface suspended sediment data were available from the SO-HYBAM monitoring program (881 field SSS samples). MODIS-derived sediment discharge closely matched the field observations, showing a relative RMSE value of 27.3% (0.48 Mtday) overall. Satellite-retrieved annual sediment discharge at the Tamshiyacu (Peru) and Manacapuru (Brazil) stations is estimated at 521 and 825 Mt/year, respectively. While upstream the river presents one main sediment discharge peak during the hydrological cycle, a secondary sediment discharge peak is detected downstream during the declining water levels, which is induced by sediment resuspension from the floodplain, causing a 72% increase on average from June to September.

  6. 40 CFR 63.10010 - What are my monitoring, installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... that emissions are controlled with a common control device or series of control devices, are discharged... parallel control devices or multiple series of control devices are discharged to the atmosphere through... quality control activities (including, as applicable, calibration checks and required zero and span...

  7. 40 CFR 63.10010 - What are my monitoring, installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that emissions are controlled with a common control device or series of control devices, are discharged... parallel control devices or multiple series of control devices are discharged to the atmosphere through... quality control activities (including, as applicable, calibration checks and required zero and span...

  8. 40 CFR 60.185 - Monitoring of operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Lead... reverberatory furnace, or sintering machine discharge end. The span of this system shall be set at 80 to 100... discharged into the atmosphere from any sintering machine, electric furnace or converter subject to § 60.183...

  9. Two approaches for estimating discharge on ungauged basins in Oregon, USA

    EPA Science Inventory

    Detailed information on the hydrologic behavior of streams is available for only a small proportion of all streams. Even in cases where discharge has been monitored, these measurements may not be available for a sufficiently long period to characterize the full behavior of a str...

  10. Observations of volcanic hotspots with TET-1

    NASA Astrophysics Data System (ADS)

    Zakšek, Klemen; Hort, Matthias; Lorenz, Eckehard

    2016-04-01

    The most important source of uncertainties in thermal monitoring of active volcanoes from space stems from the lack of dedicated satellite instruments. Considering the currently available technology, we usually have to make a compromises between spatial and temporal resolution - if the data is available at high temporal resolution (from geostationary instruments), it is impossible to provide high spatial resolution data. The most promising solution seems to be a constellation of small satellites, for they can provide data at high spatial resolution and provide a short revisit time as there is a high number of satellites in the constellation. It is also difficult to provide narrow spectral channels at high radiometric accuracy for monitoring high and low temperatures at the same time. Instruments designed for meteorological applications are usually used in remote sensing of volcanic thermal anomalies. These instruments contain a mid-infrared channel, which provides crucial data for monitoring active volcanoes. However, the settings of meteorological instruments are optimized for monitoring low temperatures, which results in often saturated data over active volcanoes. The volcanological community can partially overcome the gap between the available meteorological satellites and its requirements with the small satellite TET-1 German abbreviation for "Technologie-Erprobungsträger 1" meaning Technology Experiment Carrier). TET-1 is the first satellite within the FireBird constellation. This consists of two small satellites which are predominantly dedicated to investigating high temperature events. They were built and are operated by the German Aerospace Center. TET-1 was launched in June 2012. Here we present the first results obtained from TET-1 data. The data were retrieved over several volcanoes: Etna, Stromboli, Bárdarbunga, etc. We show that using TET-1 data, it is possible to better constrain the time averaged lava discharge from other satellite data sources.

  11. Water quality of stormwater generated from an airport in a cold climate, function of an infiltration pond, and sampling strategy with limited resources.

    PubMed

    Jia, Yu; Ehlert, Ludwig; Wahlskog, Cecilia; Lundberg, Angela; Maurice, Christian

    2017-12-05

    Monitoring pollutants in stormwater discharge in cold climates is challenging. An environmental survey was performed by sampling the stormwater from Luleå Airport, Northern Sweden, during the period 2010-2013, when urea was used as a main component of aircraft deicing/anti-icing fluids (ADAFs). The stormwater collected from the runway was led through an oil trap to an infiltration pond to store excess water during precipitation periods and enhance infiltration and water treatment. Due to insufficient capacity, an emergency spillway was established and equipped with a flow meter and an automatic sampler. This study proposes a program for effective monitoring of pollutant discharge with a minimum number of sampling occasions when use of automatic samplers is not possible. The results showed that 90% of nitrogen discharge occurs during late autumn before the water pipes freeze and during snow melting, regardless of the precipitation during the remaining months when the pollutant discharge was negligible. The concentrations of other constituents in the discharge were generally low compared to guideline values. The best data quality was obtained using flow controlled sampling. Intensive time-controlled sampling during late autumn (few weeks) and snow melting (2 weeks) would be sufficient for necessary information. The flow meters installed at the rectangular notch appeared to be difficult to calibrate and gave contradictory results. Overall, the spillway was dry, as water infiltrated into the pond, and stagnant water close to the edge might be registered as flow. Water level monitoring revealed that the infiltration capacity gradually decreased with time.

  12. Monitoring of bioengineering stabilization projects : final report.

    DOT National Transportation Integrated Search

    2009-08-01

    Four sites with bioengineered stream banks were monitored for four years. Observations included quantitative : measurements of stream discharge, stage and velocity. No bank erosion was observed to have affected the stream : banks at any of the monito...

  13. Satellite Monitoring of Oil Spills in the Mediterranean Sea For 1999-2004

    NASA Astrophysics Data System (ADS)

    Topouzelis, Konstantinos; Muellenhoff, Oliver; Tarchi, Dario; Ferraro, Guido

    2008-01-01

    Besides accidental pollution caused by ships in distress, different types of routine ship operations lead to deliberate discharges of oil in the sea. Accidental pollution at sea can be reduced but never completely eliminated. On the other hand, deliberate illegal discharges from ships can indeed be reduced by the strict enforcement of existing regulations and the control, monitoring and surveillance of maritime traffic. Operational discharges are the greatest source of marine pollution from ships, and the one which poses a long-term threat to the marine and coastal environment.The present activities of the Joint Research Centre (JRC), in the field of monitoring sea-based oil pollution using space-borne radar imagery are described. The results obtained for the period 1999-2004 for the Mediterranean Sea are presented. This analysis is of special interest due to the lack of a regular aerial surveillance as that in the North and Baltic Sea. This action helped to reveal what the dimension of the oil pollution problem is, thus stressing the need for more concerted international actions.

  14. Measuring bed load discharge in rivers: bedload-surrogate monitoring workshop Minneapolis, Minnesota, 11-14 April 2007

    USGS Publications Warehouse

    Gray, John R.; Laronne, Jonathan B.; Marr, Jeffrey D.G.

    2007-01-01

    The International Bedload-Surrogate Monitoring Workshop (http://www.nced.umn.edu/BRIC_2007.html), organized by the Bedload Research International Cooperative (BRIC; www.bedloadresearch.org), was held to assess and abet progress in continuous, semiautomated, or fully automated (surrogate) technologies for monitoring bed load discharge in gravel-, sand-, and mixed gravel-sand-bedded rivers. Direct bed load measurements, particularly at medium and high flows, during which most bed load occurs, tend to be time-consuming, expensive, and potentially hazardous. Surrogate technologies developed largely over the past decade and used at a number of research sites around the world show considerable promise toward providing relatively dense, robust, and quantifiably reliable bed load data sets. However, information on the efficacy of selected technologies for use in monitoring programs is needed, as is identification of the ways and means for bringing the most promising and practical of the technologies to fruition.

  15. A prototype of an electric-discharge gas flow oxygen-iodine laser: I. Modeling of the processes of singlet oxygen generation in a transverse cryogenic slab RF discharge

    NASA Astrophysics Data System (ADS)

    Vagin, N. P.; Ionin, A. A.; Kochetov, I. V.; Napartovich, A. P.; Sinitsyn, D. V.; Yuryshev, N. N.

    2017-03-01

    The existing kinetic model describing self-sustained and electroionization discharges in mixtures enriched with singlet oxygen has been modified to calculate the characteristics of a flow RF discharge in molecular oxygen and its mixtures with helium. The simulations were performed in the gas plug-flow approximation, i.e., the evolution of the plasma components during their motion along the channel was represented as their evolution in time. The calculations were carried out for the O2: He = 1: 0, 1: 1, 1: 2, and 1: 3 mixtures at an oxygen partial pressure of 7.5 Torr. It is shown that, under these conditions, volumetric gas heating in a discharge in pure molecular oxygen prevails over gas cooling via heat conduction even at an electrode temperature as low as 100 K. When molecular oxygen is diluted with helium, the behavior of the gas temperature changes substantially: heat removal begins to prevail over volumetric gas heating, and the gas temperature at the outlet of the discharge zone drops to 220-230 K at room gas temperature at the inlet, which is very important in the context of achieving the generation threshold in an electric-discharge oxygen-iodine laser based on a slab cryogenic RF discharge.

  16. Physical characteristics and chemical quality of selected springs in parts of Juab, Millard, Tooele, and Utah counties, Utah

    USGS Publications Warehouse

    Wilberg, D.E.; Stolp, B.J.

    1985-01-01

    Hydrologic, geologic, and partial water quality data were collected at 90 selected springs in west-central Utah, and chemical analyses performed on water samples from 62 of the springs. Descriptions of the physiographic and geologic conditions, climate, and vegetation patterns for the study area are included. Allowable limits of certain chemical constituents in water for human and livestock consumption are included with the water quality data. Three classifications of springs were established based on physical characteristics of the springs, and chemical composition of the springflow: (1) mountain springs; (2) non-thermal valley springs, and (3) thermal valley springs. Mountain springs are in and near recharge areas, have seasonal variations of discharge and temperature, typically discharge from extrusive and metamorphic geohydrologic units, and generally discharge freshwater. Non-thermal valley springs are peripheral to recharge areas, have seasonal variations of discharge and temperature, typically discharge from a variety of geohydrologic units, and have variable water composition. Thermal valley springs are near topographic low areas of valleys , and have little seasonal variation of discharge or temperature. They typically discharge from unconsolidated deposits (but the discharge probably has flowed through buried carbonate geohydrologic units). They also have a considerable range of water composition that reflects the relative complexity of the groundwater system. (Author 's abstract)

  17. Water resources data for Pennsylvania, water year 1994. Volume 2. Susquehanna and Potomac River basins. Water-data report (Annual), 1 October 1993-30 September 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durlin, R.R.; Schaffstall, W.P.

    1996-03-01

    Volume 2 contains: (1) discharge records for 94 continuous-record streamflow-gaging stations and 39 partial-record stations; (2) elevation and contents records for 12 lakes and reservoirs; (3) water-quality records for 17 gaging stations and 125 partial-record and project stations; and (4) water-level records for 25 observation wells. Additional water data collected at various sites not involved in the systematic data-collection program are also presented.

  18. Water resources data for California, water year 1995. Volume 1. Southern Great Basin from Mexican border to Mono Lake basin, and Pacific slope basins from Tijuana River to Santa Maria River. Water-data report (Annual), 1 October 1994-30 SeptembeR 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agajanian, J.A.; Rockwell, G.L.; Hayes, P.D.

    1996-04-01

    Volume 1 contains (1) discharge records for 141 streamflow-gaging stations, 6 crest-stage partial-record streamflow stations; (2) stage and contents records for 20 lakes and reservoirs; (3) water quality records for 21 streamflow-gaging stations and 3 partial-record stations; and (4) precipitation records for 1 station.

  19. Monitoring the hydrothermal system in Long Valley caldera, California

    USGS Publications Warehouse

    Farrar, C.D.; Sorey, M.L.

    1985-01-01

    An ongoing program to monitor the hydrothermal system in Long Valley for changes caused by volcanic or tectonic processes has produced considerable data on the water chemistry and discharge of springs and fluid temperatures and pressures in wells. Chemical and isotopic data collected under this program have greatly expanded the knowledge of chemical variability both in space and time. Although no chemical or isotopic changes in hot spring waters can be attributed directly to volcanic or tectonic processes, changes in hot spring chemistry that have been recorded probably relate to interactions between and variations in the quantity of liquid and gas discharged. Stable carbon isotope data are consistent with a carbon source either perform the mantle or from metamorphosed carbonate rocks. Continuous and periodic measurements of hot spring discharge at several sites show significant co seismic and a seismic changes since 1980.

  20. Rainfall, Discharge, and Water-Quality Data During Stormwater Monitoring, July 1, 2008, to June 30, 2009 - Halawa Stream Drainage Basin and the H-1 Storm Drain, Oahu, Hawaii

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.

    2009-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream, and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at five stations, and water-quality data at six stations, which include the five continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2008, and June 30, 2009. Within the Halawa Stream drainage area, three storms (October 25 and December 11, 2008, and February 3, 2009) were sampled during July 1, 2008, to June 30, 2009. A total of 43 environmental samples were collected during these three storms. During the storm of October 25, 2009, 31 samples were collected and analyzed individually for metals only. The other 12 samples from the other two storms were analyzed for some or all of the following analytes: total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for some or all of the following analytes: oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some grab and composite samples were analyzed for only a partial list of these analytes, either because samples could not be delivered to the laboratory in a timely manner, or an insufficient volume of sample was collected by the automatic samplers. Two quality-assurance/quality-control samples were collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. Four environmental samples were collected at the H-1 Storm Drain during July 1, 2008, to June 30, 2009. An oil and grease sample and a composite sample were collected during the storm on November 15, 2008, and two composite samples were collected during the January 11, 2009, storm. All samples at this site were collected using an automatic sampler. Samples were analyzed for some or all of the following analytes: total suspended solids, nutrients, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). One qualityassurance/quality-control sample was collected after cleaning automatic sampler lines to verify that the sampling lines were not contaminated. During the storm of January 11, 2009, the two composite samples collected at H-1 Storm Drain were collected about three hours apart. Higher constituent concentrations were detected in the first 2 composite sample relative to the second composite sample, although the average discharge was higher during the period when the second sample was collected.

  1. Experimental research on medium-frequency discharge cleaning in the HT-6M tokamak

    NASA Astrophysics Data System (ADS)

    Li, Chengfu; Guo, Wenkang; Gu, Xuemao; Luo, Nanchang; Hu, Wanfen; Cheng, Shanhua; Qian, Chao

    1989-04-01

    Surface cleaning experiments of the wall of HT-6M tokamak chamber by medium-frequency discharge (MFD) in hydrogen has been monitored and analysed by. QMS and AES. After 300 min discharge, the signals with mass number 12 and 18 were 100 times less than their initial values. The concentration of C and O on the wall surface decreased to 26% and 5.8%, respectively. The cleaning efficiency of MFD has been compared with that of DC glow discharge. The results showed that the former was superior to the later in ability of water release.

  2. Automatic dilution gaging of rapidly varying flow

    USGS Publications Warehouse

    Duerk, M.D.

    1983-01-01

    The analysis showed that the discharges measured by dye-dilution techniques were generally within ± 10 percent of the discharges determined from ratings established by current-meter measurements. Larger differences were noted at the start of and on the rising limb of four hydrographs. Of the 20 storms monitored, dilution measurements on 17 were of acceptable accuracy. Peak discharges from the open-channel site ranged from 0 to 12 percent departures from the existing rating whereas the comparison of peak discharge at the storm sewer site ranged from 0 to 5 percent departures from the existing rating.

  3. Dynamics of multiple double layers in high pressure glow discharge in a simple torus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar Paul, Manash, E-mail: manashkr@gmail.com; Sharma, P. K.; Thakur, A.

    2014-06-15

    Parametric characterization of multiple double layers is done during high pressure glow discharge in a toroidal vessel of small aspect ratio. Although glow discharge (without magnetic field) is known to be independent of device geometry, but the toroidal boundary conditions are conducive to plasma growth and eventually the plasma occupy the toroidal volume partially. At higher anode potential, the visibly glowing spots on the body of spatially extended anode transform into multiple intensely luminous spherical plasma blob structures attached to the tip of the positive electrode. Dynamics of multiple double layers are observed in argon glow discharge plasma in presencemore » of toroidal magnetic field. The radial profiles of plasma parameters measured at various toroidal locations show signatures of double layer formation in our system. Parametric dependence of double layer dynamics in presence of toroidal magnetic field is presented here.« less

  4. Thermal Pollution Mathematical Model. Volume 3: User's Manual for One-Dimensional Numerical Model for the Seasonal Thermocline. [environment impact of thermal discharges from power plants

    NASA Technical Reports Server (NTRS)

    Lee, S. S.; Sengupta, S.; Nwadike, E. V.

    1980-01-01

    A user's manual for a one dimensional thermal model to predict the temperature profiles of a deep body of water for any number of annual cycles is presented. The model is essentially a set of partial differential equations which are solved by finite difference methods using a high speed digital computer. The model features the effects of area change with depth, nonlinear interaction of wind generated turbulence and buoyancy, adsorption of radiative heat flux below the surface, thermal discharges, and the effects of vertical convection caused by discharge. The main assumption in the formulation is horizontal homogeneity. The environmental impact of thermal discharges from power plants is emphasized. Although the model is applicable to most lakes, a specific site (Lake Keowee, S.C.) application is described in detail. The programs are written in FORTRAN 5.

  5. Inert gas ion thruster development

    NASA Technical Reports Server (NTRS)

    Ramsey, W. D.

    1980-01-01

    Two 12 cm magneto-electrostatic containment (MESC) ion thrusters were performance mapped with argon and xenon. The first, hexagonal, thruster produced optimized performance of 48.5to 79 percent argon mass utilization efficiencies at discharge energies of 240 to 425 eV/ion, respectively, Xenon mass utilization efficiencies of 78 to 95 percent were observed at discharge energies of 220 to 290 eV/ion with the same optimized hexagonal thruster. Changes to the cathode baffle reduced the discharge anode potential during xenon operation from approximately 40 volts to about 30 volts. Preliminary tests conducted with the second, hemispherical, MESC thruster showed a nonuniform anode magnetic field adversely affected thruster performance. This performance degradation was partially overcome by changes in the boundary anode placement. Conclusions drawn the hemispherical thruster tests gave insights into the plasma processes in the MESC discharge that will aid in the design of future thrusters.

  6. Water Resources Data, West Virginia, Water Year 2003

    USGS Publications Warehouse

    Ward, S.M.; Rosier, M.T.; Crosby, G.R.

    2004-01-01

    Water-resources data for the 2003 water year for West Virginia consists of records of stream discharge, reservoir and ground-water levels, and water quality of streams and ground-water wells. This report contains discharge records for 70 streamflow-gaging stations; discharge records provided by adjacent states for 8 streamflow-gaging stations; annual maximum discharge at 16 crest-stage partial-record stations; stage records for 6 detention reservoirs; water-quality records for 2 stations; and water-level records for 8 observation wells. Locations of streamflow, detention reservoir, and water-quality stations are shown on figure 4. Locations of ground-water observation wells are shown on figure 5. Additional water data were collected at various sites, not involved in the systematic data-collection program, and are published as miscellaneous sites. These data represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in West Virginia.

  7. Water resources data-West Virginia, water year 2004

    USGS Publications Warehouse

    Ward, S.M.; Rosier, M.T.; Crosby, G.R.

    2005-01-01

    Water-resources data for the 2004 water year for West Virginia consist of records of stream discharge, reservoir and ground-water levels, and water quality of streams and ground-water wells. This report contains discharge records for 65 streamflow-gaging stations; discharge records provided by adjacent states for 8 streamflow-gaging stations; annual maximum discharge at 17 crest-stage partial-record stations; stage records for 14 detention reservoirs; water-quality records for 2 stations; and water-level records for 10 observation wells. Locations of streamflow, detention reservoir, and water-quality stations are shown on figure 4. Locations of ground-water observation wells are shown on figure 5. Additional water-quality data were collected at various sites, not involved in the systematic data collection program, and are published as miscellaneous sites. These data represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in West Virginia.

  8. Eight electrode optical readout gap

    DOEpatents

    Boettcher, G.E.; Crain, R.W.

    1984-01-01

    A protective device for a plurality of electrical circuits includes a plurality of isolated electrodes forming a gap with a common electrode. An output signal, electrically isolated from the circuits being monitored, is obtained by a photosensor viewing the discharge gap through an optical window. Radioactive stabilization of discharge characteristics is provided for slowly changing voltages and carbon tipped dynamic starters provide desirable discharge characteristics for rapidly varying voltages. A hydrogen permeation barrier is provided on external surfaces of the device.

  9. RESULTS OF TRITIUM TRACKING AND GROUNDWATER MONITORING AT THE HANFORD SITE 200 AREA STATE APPROVED LAND DISPOSAL SITE FY2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ERB DB

    2008-11-19

    The Hanford Site's 200 Area Effluent Treatment Facility (ETF) processes contaminated aqueous wastes derived from Hanford Site facilities. The treated wastewater occasionally contains tritium, which cannot be removed by the ETF prior to the wastewater being discharged to the 200 Area State-Approved Land Disposal Site (SALDS). During the first 11 months of fiscal year 2008 (FY08) (September 1, 2007, to July 31, 2008), approximately 75.15 million L (19.85 million gal) of water were discharged to the SALDS. Groundwater monitoring for tritium and other constituents, as well as water-level measurements, is required for the SALDS by State Waste Discharge Permit Numbermore » ST-4500 (Ecology 2000). The current monitoring network consists of three proximal (compliance) monitoring wells and nine tritium-tracking wells. Quarterly sampling of the proximal wells occurred in October 2007 and in January/February 2008, April 2008, and August 2008. The nine tritium-tracking wells, including groundwater monitoring wells located upgradient and downgradient of the SALDS, were sampled in January through April 2008. Water-level measurements taken in the three proximal SALDS wells indicate that a small groundwater mound is present beneath the facility, which is a result of operational discharges. The mound increased in FY08 due to increased ETF discharges from treating groundwater from extraction wells at the 200-UP-l Operable Unit and the 241-T Tank Farm. Maximum tritium activities increased by an order of magnitude at well 699-48-77A (to 820,000 pCi/L in April 2008) but remained unchanged in the other two proximal wells. The increase was due to higher quantities of tritium in wastewaters that were treated and discharged in FY07 beginning to appear at the proximal wells. The FY08 tritium activities for the other two proximal wells were 68,000 pCi/L at well 699-48-77C (October 2007) and 120,000 pCi/L at well 699-48-77D (October 2007). To date, no indications of a tritium incursion from the SALDS have been detected in the tritium-tracking wells. Concentrations of all chemical constituents were within Permit limits or were below method detection limits when sampled during FY08. A summary of the chemical constituent concentrations or method detection limits is provided in Table 3-2 in the main text discussion. This report presents the results of groundwater monitoring and tritium-tracking samples from the SALDS facility during FY08. Due to the 30-day laboratory turnaround for analysis of proximal well groundwater samples, this report addresses available date extending from August 1, 2007, through September 30, 2008 (August 2007 data were not included in the FY07 report). Updated background information, which is necessary to understand the results of the groundwater analyses, is also provided on facility operations. Interpretive discussions and recommendations for future monitoring are also provided, where possible.« less

  10. Loch Vale Watershed Long-Term Ecological Research and Monitoring Program: Quality Assurance Report, 2003-09

    USGS Publications Warehouse

    Richer, Eric E.; Baron, Jill S.

    2011-01-01

    The Loch Vale watershed project is a long-term research and monitoring program located in Rocky Mountain National Park that addresses watershed-scale ecosystem processes, particularly as they respond to atmospheric deposition and climate variability. Measurements of precipitation depth, precipitation chemistry, discharge, and surface-water quality are made within the watershed and elsewhere in Rocky Mountain National Park. As data collected for the program are used by resource managers, scientists, policy makers, and students, it is important that all data collected in Loch Vale watershed meet high standards of quality. In this report, data quality was evaluated for precipitation, discharge, and surface-water chemistry measurements collected during 2003-09. Equipment upgrades were made at the Loch Vale National Atmospheric Deposition Program monitoring site to improve precipitation measurements and evaluate variability in precipitation depth and chemistry. Additional solar panels and batteries have been installed to improve the power supply, and data completeness, at the NADP site. As a result of equipment malfunction, discharge data for the Loch Outlet were estimated from October 18, 2005, to August 17, 2006. Quality-assurance results indicate that more than 98 percent of all surface-water chemistry measurements were accurate and precise. Records that did not meet quality criteria were removed from the database. Measurements of precipitation depth, precipitation chemistry, discharge, and surface-water quality were all sufficiently complete and consistent to support project data needs.

  11. The hydrogen isotope ratio in W7-AS during deuterium NBI heating

    NASA Astrophysics Data System (ADS)

    Zebisch, P.; Taglauer, E.; W7-AS Team; NBI Team

    1999-04-01

    With a so-called sniffer probe the fraction of hydrogen during discharges with deuterium NBI heating was studied in the plasma edge of the stellarator W7-AS. As expected, the ratios were significantly lower than in discharges with hydrogen NBI heating but were higher than those in discharges with only ECRH. An examination of the possible reasons for this increase concludes that it is not only partially caused by the direct influence of neutral injection but also depends on the energy content of the plasma determined by the heating power and the confinement time. Of course, the isotope ratio also depends on the starting conditions, i.e. the isotope ratio before the onset of NBI.

  12. GIS diagnostics: thermal imaging systems used for poor contact detection

    NASA Astrophysics Data System (ADS)

    Avital, Doron; Brandenbursky, V.; Farber, A.

    2004-04-01

    The reliability of GIS is very high but any failure that occurs can cause extensive damage result and the repair times are considerably long. The consequential losses to system security and economically can be high, especially if the nominal GIS voltage is 420 kV and above. In view of these circumstances, increasing attention is being given to diagnostic techniques for in-service maintenance undertaken to improve the reliability and availability of GIS. Recently considerable progress has been made in diagnostic techniques and they are now used successfully during the service life of the equipment. These diagnostic techniques in general focus on the GIS insulation system and are based on partial discharge (PD) measurements in GIS. There are three main methods for in-service PD detection in GIS: - the chemical method that rely on the detection of cracked gas caused by PD, the acoustic method designed to detect the acoustic emission excited by PD, and, the electrical method which is based on detection of electrical resonance at ultra high frequencies (UHF) up to 1.5 GHz caused by PD excitation in GIS chambers (UHF method). These three dielectric diagnostic methods cannot be used for the detection of poor current carrying contacts in GIS. This problem does not always produce partial discharges and at early stages it does not cause gas cracking. An interesting solution to use two techniques - the current unbalance alarm scheme and partial discharge monitoring was advised by A. Salinas from South California Edison Co. Unfortunately this way is complicated and very expensive. The investigations performed in Japan on standing alone SF6 breaker showed that joule heating of the contact accompanied by released power of 1600 Watt produce temperature difference on the enclosure up to 7 degrees centigrade that could be detected by infra-red Thermal Imaging System. According to CIGRE Joint Working Group 33/23.12 Report, 11% of all GIS failures are due to poor current carrying contacts in GIS. The Israel Electric Company (IEC) in seeking a solution to this problem have undertaken experimental work to examine the possibility of in-service diagnostic of poor contact problem in GIS via direct local heating detection, using a Thermal Imaging System. The experiments were carried out on the part of the GIS with nominal SF6 pressure. The following aspects of the problem were examined: - the range of power released in the defective contact that could give the practical temperature rise on the surface of enclosure; - temperature distribution on the surface of enclosure; - the influence of spacer type (with holes or without) on the heat transfer process; - the influence of the length of SF6 tubes and there position (horizontal or vertical); - the temperature difference between upper and lower parts of the tubes in horizontal position; - practical use of the Thermal Imaging System for detecting poor contact problem in GIS.

  13. A lithium oxygen secondary battery

    NASA Technical Reports Server (NTRS)

    Semkow, Krystyna W.; Sammells, Anthony F.

    1987-01-01

    Some recent work on a lithium-oxygen secondary battery is reported in which stabilized zirconia oxygen vacancy conducting solid electrolytes were used for the effective separation of respective half-cell reactions. The electroactive material consisted of alloys possessing the general composition Li(x)FeSi2 immersed in a ternary molten salt comprising LiF, LiCl, and Li2O. The manufacture of the cell is described, and discharge-current voltage curves for partially charged cells are shown and discussed. A galvanostatic IR free-changing curve and an IR-free charge-discharge curve are also shown.

  14. On the exploitation of optical and thermal band for river discharge estimation: synergy with radar altimetry

    NASA Astrophysics Data System (ADS)

    Tarpanelli, Angelica; Filippucci, Paolo; Brocca, Luca

    2017-04-01

    River discharge is recognized as a fundamental physical variable and it is included among the Essential Climate Variables by GCOS (Global Climate Observing System). Notwithstanding river discharge is one of the most measured components of the hydrological cycle, its monitoring is still an open issue. Collection, archiving and distribution of river discharge data globally is limited, and the currently operating network is inadequate in many parts of the Earth and is still declining. Remote sensing, especially satellite sensors, have great potential in offering new ways to monitor river discharge. Remote sensing guarantees regular, uniform and global measurements for long period thanks to the large number of satellites launched during the last twenty years. Because of its nature, river discharge cannot be measured directly and both satellite and traditional monitoring are referred to measurements of other hydraulic variables, e.g. water level, flow velocity, water extent and slope. In this study, we illustrate the potential of different satellite sensors for river discharge estimation. The recent advances in radar altimetry technology offered important information for water levels monitoring of rivers even if the spatio-temporal sampling is still a limitation. The multi-mission approach, i.e. interpolating different altimetry tracks, has potential to cope with the spatial and temporal resolution, but so far few studies were dedicated to deal with this issue. Alternatively, optical sensors, thanks to their frequent revisit time and large spatial coverage, could give a better support for the evaluation of river discharge variations. In this study, we focus on the optical (Near InfraRed) and thermal bands of different satellite sensors (MODIS, MERIS, AATSR, Landsat, Sentinel-2) and particularly, on the derived products such as reflectance, emissivity and land surface temperature. The performances are compared with respect to the well-known altimetry (Envisat/Ra-2, Jason-2/Poseidon-3 and Saral/Altika) for estimating the river discharge variation in Nigeria and Italy. For optical and thermal bands, results are more affected by the temporal resolution than the spatial resolution. Indeed, even if affected by cloud cover that limits the number of available images, thermal bands from MODIS (spatial resolution of 1 km) can be conveniently used for the estimation of the variation in the river discharge, whereas optical sensors as Landsat or Sentinel-2, characterized by 10 - 30 m of spatial resolution, fail in the estimation of extreme events, missing most of the peak values, because of the long revisit time ( 14-16 days). The best performances are obtained with the Near InfraRed bands from MODIS and MERIS that give similar results in river discharge estimation, even though with some underestimation of the flood peak values. Moreover, the multi-mission approach applied to radar altimetry data is found to be the most reliable tool to estimate river discharge in large rivers but its success is constrained both spatially (number of satellite tracks) and temporally (revisit time of the satellites). Therefore, it is expected that the multi-mission approach, merging also sensors of different characteristics (radar altimetry, and optical/thermal sensors), could improve the performances, if a consistent and comparable methodology is used for reducing the inter-satellite biases.

  15. Study of Gallium Arsenide Etching in a DC Discharge in Low-Pressure HCl-Containing Mixtures

    NASA Astrophysics Data System (ADS)

    Dunaev, A. V.; Murin, D. B.

    2018-04-01

    Halogen-containing plasmas are often used to form topological structures on semiconductor surfaces; therefore, spectral monitoring of the etching process is an important diagnostic tool in modern electronics. In this work, the emission spectra of gas discharges in mixtures of hydrogen chloride with argon, chlorine, and hydrogen in the presence of a semiconducting gallium arsenide plate were studied. Spectral lines and bands of the GaAs etching products appropriate for monitoring the etching rate were determined. It is shown that the emission intensity of the etching products is proportional to the GaAs etching rate in plasmas of HCl mixtures with Ar and Cl2, which makes it possible to monitor the etching process in real time by means of spectral methods.

  16. Alternative hospital gift bags and breastfeeding exclusivity.

    PubMed

    Bai, Yeon; Wunderlich, Shahla M; Kashdan, Rickie

    2013-01-01

    The type of gift bags given to new mothers at the time of discharge from the hospital can influence their confidence in breastfeeding. Most hospitals in the US continue to distribute commercial gift bags containing formula samples despite the reported negative influence of commercial bags on the duration of breastfeeding. This study compared breastfeeding outcomes in women receiving three different kinds of gift bags at discharge. A prospective intervention study was conducted during 2009-2010 in New Jersey. Three breastfeeding cohorts were recruited and assigned to three groups: COMMERCIAL received discharge bags containing formula samples, BF-INFO received breastfeeding information and supplies, and PUMP received breastfeeding information/supplies plus a manual breast pump. Follow-up contacts were at 2, 4, and 12 postpartum weeks to determine breastfeeding outcome. The mean durations of exclusive (EBF) and partial breastfeeding were compared between groups using ANOVA. A total of 386 participants completed the study. The mean EBF duration (weeks) in the PUMP (n = 138, 8.28 ± 4.86) and BF-INFO (n = 121, 7.87 ± 4.63) were significantly longer (P < 0.01) than COMMERCIAL (n = 127, 6.12 ± 4.49). The rate of EBF through 12 weeks in PUMP was most consistent. The mean duration of partial breastfeeding showed similar results: significantly longer in PUMP and BF-INFO than COMMERCIAL (P < 0.01).

  17. Construction, Geology, and Aquifer Testing of the Maalo Road, Aahoaka Hill, and Upper Eleele Tank Monitor Wells, Kauai, Hawaii

    USGS Publications Warehouse

    Izuka, Scot K.

    2005-01-01

    The Maalo Road, Aahoaka Hill, and Upper Eleele Tank monitor wells were constructed using rotary drilling methods between July 1998 and August 2002 as part of a program of exploratory drilling, aquifer testing, and hydrologic analysis on Kauai. Aquifer tests were conducted in the uncased boreholes of the wells. The Maalo Road monitor well in the Lihue Basin penetrated 915 feet, mostly through mafic lava flows. Most of the rock samples from this well had chemical compositions similar to the Koloa Volcanics, but the deepest sample analyzed had a composition similar to the Waimea Canyon Basalt. Water temperature ranged from 25.6 to 27.4 degrees Celsius and specific conductance ranged from 303 to 627 microsiemens per centimeter during aquifer testing. Discharge rate ranged from 174 to 220 gallons per minute and maximum drawdown was 138.25 ft during a 7-day sustained-discharge test, but the test was affected by pump and generator problems. The Aahoaka Hill monitor well in the Lihue Basin penetrated 804 feet, mostly through mafic lava flows and possibly dikes. The well penetrated rocks having chemical compositions similar to the Waimea Canyon Basalt. During the first three hours of a sustained-discharge aquifer test in which the discharge rate varied between 92 and 117 gallons per minute, water temperature was 24.6 to 25.6 degrees Celsius, and specific conductance was 212 to 238 microsiemens per centimeter; this test was halted after a short period because drawdown was high. In a subsequent 7-day test, discharge was 8 to 23 gallons per minute, and maximum drawdown was 37.71 feet after 1,515 minutes of testing. The Upper Eleele Tank monitor well is near the Hanapepe River Valley. The well penetrated 740 feet through soil, sediment, mafic lava flows, volcanic ash, and scoria. Rocks above a depth of 345 feet had compositions similar to the Koloa Volcanics, but a sample from 720 to 725 feet had a composition similar to rocks of the Waimea Canyon Basalt. During a 7-day aquifer test with a sustained discharge between 278 and 290 gallons per minute, most of the drawdown of 1.10 feet occurred in the first 455 minutes of the test. Water levels measured thereafter may have been influenced by pumping from a nearby well. Water temperature ranged from 20.2 to 21.4 degrees Celsius and specific conductance from 8,380 to 18,940 microsiemens per centimeter during the aquifer tests.

  18. 40 CFR 63.10010 - What are my monitoring, installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emissions are controlled with a common control device or series of control devices, are discharged to the... devices or multiple series of control devices are discharged to the atmosphere through more than one stack... control activities (including, as applicable, calibration checks and required zero and span adjustments...

  19. Functional requirements for Waste Area Grouping 6 Monitoring Station 3 upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fiuzat, A.A.

    1991-06-01

    The surface Waste Area Grouping (WAG)6 at ORNL may undergo many changes in the future as part of the closure activities. Changes in surface characteristics will cause changes in runoff characteristics of the MS 3 watershed. Appropriate assumptions are to be made in this project regarding the future surface conditions of the watershed. The extent to which the assumed surface conditions will affect the project objectives (defined in Section 1.0) is to be identified. The purpose of this FRD is to establish performance requirements for MS 3 consisting of the following: (1) The expected range of discharges passing through themore » station and the required accuracy levels for discharge measurements. (2) The equipment required to measure the expected discharges at the required accuracy levels. (3) The sampling requirements for monitoring water quality. (4) The hydraulic requirements for the discharge conveyance structure to be located under the IWMF access road. (5) The design loads to be used for the bridge over the IWMF access road. 12 refs., 5 figs.« less

  20. Understanding the hydrologic impacts of wastewater treatment plant discharge to shallow groundwater: Before and after plant shutdown

    USGS Publications Warehouse

    Hubbard, Laura E.; Keefe, Steffanie H.; Kolpin, Dana W.; Barber, Larry B.; Duris, Joseph W.; Hutchinson, Kasey J.; Bradley, Paul M.

    2016-01-01

    Effluent-impacted surface water has the potential to transport not only water, but wastewater-derived contaminants to shallow groundwater systems. To better understand the effects of effluent discharge on in-stream and near-stream hydrologic conditions in wastewater-impacted systems, water-level changes were monitored in hyporheic-zone and shallow-groundwater piezometers in a reach of Fourmile Creek adjacent to and downstream of the Ankeny (Iowa, USA) wastewater treatment plant (WWTP). Water-level changes were monitored from approximately 1.5 months before to 0.5 months after WWTP closure. Diurnal patterns in WWTP discharge were closely mirrored in stream and shallow-groundwater levels immediately upstream and up to 3 km downstream of the outfall, indicating that such discharge was the primary control on water levels before shutdown. The hydrologic response to WWTP shutdown was immediately observed throughout the study reach, verifying the far-reaching hydraulic connectivity and associated contaminant transport risk. The movement of WWTP effluent into alluvial aquifers has implications for potential WWTP-derived contamination of shallow groundwater far removed from the WWTP outfall.

  1. Bedload component of glacially discharged sediment: Insights from the Matanuska Glacier, Alaska

    USGS Publications Warehouse

    Pearce, J.T.; Pazzaglia, F.J.; Evenson, E.B.; Lawson, D.E.; Alley, R.B.; Germanoski, D.; Denner, J.D.

    2003-01-01

    The flux of glacially derived bedload and the proportions of the suspended and bedload components carried by proglacial streams are highly debated. Published data indicate a large range-from 75%-in the bedload percentage of the total load. Two "vents," where supercooled subglacial meltwater and sediment are discharged, were sampled over the course of an entire melt season in order to quantify the flux of glacially delivered bedload at the Matanuska Glacier, Alaska. The bedload component contributed by these vents, for the one melt season monitored, is negligible. Furthermore, the bedload fluxes appear to be strongly supply limited, as shown by the poorly correlated discharge, bedload-flux magnitude, and grain-size caliber. Thus, in this case, any attempt to employ a predictive quantitative expression for coarse-sediment production based on discharge alone would be inaccurate. A nonglaciated basin proximal to the Matanuska Glacier terminus yielded higher bedload sediment fluxes and larger clast sizes than delivered by the two monitored vents. Such nonglaciated basins should not be overlooked as potentially major sources of coarse bedload that is reworked and incorporated into valley outwash.

  2. Streamflow and streambed scour in 2010 at bridge 339, Copper River, Alaska

    USGS Publications Warehouse

    Conaway, Jeffrey S.; Brabets, Timothy P.

    2011-01-01

    The distribution of the Copper River's discharge through the bridges was relatively stable until sometime between 1969-70 and 1982-85. The majority of the total Copper River discharge in 1969-70 passed through three bridges on the western side of the delta, but by 1982-1985, 25 to 62 percent of the flow passed through bridge 342 on the eastern side of the Copper River Delta. In 2004, only 8 percent of the flow passed through the western bridges, while 90 percent of the discharge flowed through two bridges on the eastern side of the delta. Migration of the river across the delta and redistribution of discharge has resulted in streambed scour at some bridges, overtopping of the road during high flows, prolonged highway closures, and formation of new channels through forests. Scour monitoring at the eastern bridges has recorded as much as 44 feet of fill at one pier and 33 feet of scour at another. In 2009, flow distribution began to shift from the larger bridge 342 to bridge 339. In 2010, flow in excess of four times the design discharge scoured the streambed at bridge 339 to a level such that constant on-site monitoring was required to evaluate the potential need for bridge closure. In 2010, instantaneous flow through bridge 339 was never less than 30 percent and was as high as 49 percent of the total Copper River discharge. The percentage of flow through bridge 339 decreased when the overall Copper River discharge increased. The increased discharge through bridge 339 is attributed to a shift in the approach channel 3,500 feet upstream. Bridge channel alignment and analysis of flow distribution as of October 2010 indicate these hydrologic hazards will persist in 2011.

  3. Behavior of Combined Dielectric-Metallic Systems in a Charged Particle Environment

    NASA Technical Reports Server (NTRS)

    Gordon, W. L.; Hoffman, R. W.

    1984-01-01

    The charging and discharging characteristics of an electrically isolated solar array segment were studied in order to simulate discharges seen during geomagnetic substorms. A solar array segment was floated while bombarded with monoenergetic electrons at various angles of incidence. The potentials of the array surface and of the interconnects were monitored using Trek voltage probes to maintain electrical isolation. A back plate was capacitively coupled to the array to provide information on the characteristics of the transients accompanying the discharges. Several modes of discharging of the array were observed at relatively low differential and absolute potentials (a few kilovolts). A relatively slow discharge response in the array was observed, discharging over one second with currents of nanoamps. Two types of faster discharges were also seen which lasted a few hundredths of a millisecond and with currents on the order of microamps. Some results indicate an electron emission process associated with the arcs.

  4. Additive hazards regression and partial likelihood estimation for ecological monitoring data across space.

    PubMed

    Lin, Feng-Chang; Zhu, Jun

    2012-01-01

    We develop continuous-time models for the analysis of environmental or ecological monitoring data such that subjects are observed at multiple monitoring time points across space. Of particular interest are additive hazards regression models where the baseline hazard function can take on flexible forms. We consider time-varying covariates and take into account spatial dependence via autoregression in space and time. We develop statistical inference for the regression coefficients via partial likelihood. Asymptotic properties, including consistency and asymptotic normality, are established for parameter estimates under suitable regularity conditions. Feasible algorithms utilizing existing statistical software packages are developed for computation. We also consider a simpler additive hazards model with homogeneous baseline hazard and develop hypothesis testing for homogeneity. A simulation study demonstrates that the statistical inference using partial likelihood has sound finite-sample properties and offers a viable alternative to maximum likelihood estimation. For illustration, we analyze data from an ecological study that monitors bark beetle colonization of red pines in a plantation of Wisconsin.

  5. Investigation and Remediation Records Concerning Incidents of Weapons Discharges by Private Security Contractors Can Be Improved

    DTIC Science & Technology

    2009-07-28

    Incidents of Weapons Discharges by Private Security Contractors Can Be Improved 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...for Iraq Reconstruction,400 Army Navy Drive,Arlington,VA,22202-4704 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S...Defense’s (DoD) oversight of incidents involving the firing—or discharge —of weapons reported from May 2008 through February 2009 by its PSCs

  6. 40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... installed in each baghouse compartment or cell. For negative pressure or induced air fabric filters, the bag... hydrogen chloride testing with EPA Method 321 at 40 CFR part 63, appendix A, an owner or operator must install, calibrate, maintain, and operate a CEMS for monitoring hydrogen chloride emissions discharged to...

  7. 40 CFR 60.2730 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... detection system must be installed in each baghouse compartment or cell. For negative pressure or induced... scrubber, in place of hydrogen chloride testing with EPA Method 321 at 40 CFR part 63, appendix A, an owner... for monitoring hydrogen chloride emissions discharged to the atmosphere and record the output of the...

  8. 40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... leak detection system must be installed in each baghouse compartment or cell. For negative pressure or... scrubber, in place of hydrogen chloride testing with EPA Method 321 at 40 CFR part 63, appendix A, an owner... for monitoring hydrogen chloride emissions discharged to the atmosphere and record the output of the...

  9. 33 CFR 157.12a - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... recordings of data as specified in § 157.12d(h)(2). Oil discharge monitoring and control system or monitoring... RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design... means a unit in a monitoring system composed of the items specified in § 157.12d(a)(4)(viii). Control...

  10. 33 CFR 157.12a - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... recordings of data as specified in § 157.12d(h)(2). Oil discharge monitoring and control system or monitoring... RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design... means a unit in a monitoring system composed of the items specified in § 157.12d(a)(4)(viii). Control...

  11. 33 CFR 157.12a - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... recordings of data as specified in § 157.12d(h)(2). Oil discharge monitoring and control system or monitoring... RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design... means a unit in a monitoring system composed of the items specified in § 157.12d(a)(4)(viii). Control...

  12. 33 CFR 157.12a - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... recordings of data as specified in § 157.12d(h)(2). Oil discharge monitoring and control system or monitoring... RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design... means a unit in a monitoring system composed of the items specified in § 157.12d(a)(4)(viii). Control...

  13. 33 CFR 157.12a - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... recordings of data as specified in § 157.12d(h)(2). Oil discharge monitoring and control system or monitoring... RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design... means a unit in a monitoring system composed of the items specified in § 157.12d(a)(4)(viii). Control...

  14. Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery: A retrospective analysis of 685 patients.

    PubMed

    Kim, Sung-Hoon; Jin, Seok-Joon; Karm, Myong-Hwan; Moon, Young-Jin; Jeong, Hye-Won; Kim, Jae-Won; Ha, Seung-Il; Kim, Joung-Uk

    2016-08-01

    Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results between no and partial NMB during cerebral aneurysm clipping surgery. We reviewed patient medical records for demographic data, anesthesia regimen, neurophysiology event logs, MEP results, and clinical outcomes. Patients were divided into 2 groups according to the intraoperative use of NMB: no NMB group (n = 276) and partial NMB group (n = 409). We compared the diagnostic accuracy of MEP results to predict postoperative outcomes between both groups. Additionally, we evaluated unwanted patient movement during MEP monitoring in both groups. Of the 685 patients, 622 (90.8%) manifested no intraoperative changes in MEP and no postoperative motor deficits. Twenty patients showed postoperative neurologic deficits despite preserved intraoperative MEP. False-positive MEP results were 3.6% in the no NMB group and 3.9% in the partial NMB group (P = 1.00). False-negative MEP results were 1.1% in the no NMB group and 4.2% in the partial NMB group (P = 0.02). No spontaneous movement or spontaneous respiration was observed in either group. Propofol/remifentanil-based anesthesia without NMB decreases the stimulation intensity of MEPs, which may reduce the false-negative ratio of MEP monitoring during cerebral aneurysm surgery. Our anesthetic protocol enabled reliable intraoperative MEP recording and patient immobilization during cerebral aneurysm clipping surgery.

  15. Microbial and Nutrient Concentration and Load Data During Stormwater Runoff at a Swine Concentrated Animal Feeding Operation in the North Carolina Coastal Plain, 2006-2007

    USGS Publications Warehouse

    Harden, Stephen L.

    2008-01-01

    This report summarizes water-quality and hydrologic data collected during 2006-2007 to characterize bacteria and nutrient loads associated with overland runoff and subsurface tile drainage in spray fields at a swine concentrated animal feeding operation. Four monitoring locations were established at the Lizzie Research Site in the North Carolina Coastal Plain Physiographic Province for collecting discharge and water-quality data during stormwater-runoff events. Water stage was measured continuously at each monitoring location. A stage-discharge relation was developed for each site and was used to compute instantaneous discharge values for collected samples. Water-quality samples were collected for five storm events during 2006-2007 for analysis of nutrients and fecal indicator bacteria. Instantaneous loads of nitrite plus nitrate, total coliform, Escherichia coli (E. coli), and enterococci were computed for selected times during the five storm events.

  16. NEXIS Reservoir Cathode 2000 Hour Life Test

    NASA Technical Reports Server (NTRS)

    Vaughn, Jason; Schneider, Todd; Polk, Jay; Goebel, Dan; Ohlinger, Wayne; Hill, D. Norm

    2004-01-01

    The current design of the Nuclear Electric Xenon Ion System (NEXIS) employs a reservoir cathode as both the discharge and neutralizer cathode to meet the 10 yr thruster design life. The main difference between a reservoir cathode and a conventional discharge cathode is the source material (barium-containing compound) is contained within a reservoir instead of in an impregnated insert in the hollow tube. However, reservoir cathodes do not have much life test history associated with them. In order to demonstrate the feasibility of using a reservoir cathode as an integral part of the NEXIS ion thruster, a 2000 hr life test was performed. Several proof-of-concept (POC) reservoir cathodes were built early in the NEXIS program to conduct performance testing as well as life tests. One of the POC cathodes was sent to Marshall Space Flight Center (MSFC) where it was tested for 2000 hrs in a vacuum chamber. The cathode was operated at the NEXIS design point of 25 A discharge current and a xenon flow rate of 5.5 sccm during the 2000 hr test. The cathode performance parameters, including discharge current, discharge voltage, keeper current; keeper voltage, and flow rate were monitored throughout test. Also, the temperature upstream of cathode heater, the temperature downstream of the cathode heater, and the temperature of the orifice plate were monitored throughout the life of the test. The results of the 2000 hr test will be described in this paper. Included in the results will be time history of discharge current, discharge voltage, and flow rate. Also, a time history of the cathode temperature will be provided.

  17. 2014 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Mike

    2015-02-01

    This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  18. Geochemical and statistical evidence of recharge, mixing, and controls on spring discharge in an eogenetic karst aquifer

    NASA Astrophysics Data System (ADS)

    Moore, Paul J.; Martin, Jonathan B.; Screaton, Elizabeth J.

    2009-10-01

    SummaryInformation about sources of recharge, distributions of flow paths, and the extent of water-rock reactions in karst aquifers commonly result from monitoring spring chemistry and discharge. To investigate the relationship between spring characteristics and the complexities of karst aquifers, we couple variations in surface- and groundwater chemistry to physical conditions including river stage, precipitation, and evapotranspiration (ET) within a sink-rise system through a 6-km portion of the Upper Floridan aquifer (UFA) in north-central Florida. Principal component analysis (PCA) of time series major-element compositions suggests that at least three sources of water affect spring discharge, including allogenic recharge into a swallet, diffuse recharge through a thin vadose zone, and water upwelling from deep within the aquifer. The deep-water source exerts the strongest influence on water chemistry by providing a majority of Na +, Mg 2+, K +, Cl -, and SO42- to the system. Anomalously high temperature at one of several monitoring wells reflects vertical flow of about 1 m/year. Mass-balance calculations suggest diffuse recharge and deep-water upwelling can provide up to 50% of the spring discharge; however, their contributions depend on head gradients between the conduit and surrounding aquifer matrix, which are influenced by variations in precipitation, ET, and river stage. Our results indicate that upwelling from deep flow paths may provide significant contributions of water to spring discharge, and that monitoring only springs limits interpretations of karst systems by masking critical components of the aquifer, such as water sources and flow paths. These results also suggest the matrix in eogenetic aquifers is a major pathway for flow even in a system dominated by conduits.

  19. Water column monitoring of the biological effects of produced water from the Ekofisk offshore oil installation from 2006 to 2009.

    PubMed

    Brooks, Steven J; Harman, Christopher; Grung, Merete; Farmen, Eivind; Ruus, Anders; Vingen, Sjur; Godal, Brit F; Barsiene, Janina; Andreikenaite, Laura; Skarpheðinsdottir, Halldóra; Liewenborg, Birgitta; Sundt, Rolf C

    2011-01-01

    The Norwegian water column monitoring program investigates the biological effects of offshore oil and gas activities in Norwegian waters. In three separate surveys in 2006, 2008, and 2009, bioaccumulation and biomarker responses were measured in mussels (Mytilus edulis) and Atlantic cod (Gadus morhua) held in cages at known distances from the produced water (PW) discharge at the Ekofisk oil field. Identical monitoring studies performed in all three years have allowed the biological effects and bioaccumulation data to be compared, and in addition, enabled the potential environmental benefits of a PW treatment system (CTour), implemented in 2008, to be evaluated. The results of the 2009 survey showed that caged animals were exposed to low levels of PW components, with highest tissue concentrations in mussels located closest to the PW discharge. Mussels located approximately 1-2 km away demonstrated only background concentrations of target compounds. Concentrations of polycyclic aromatic hydrocarbons (PAH) and alkyl phenol (AP) metabolites in the bile of caged cod were elevated at stations 200-250 m from the discharge. There was also a signal of exposure relative to discharge for the biomarkers CYP1A in fish and micronuclei in mussels. All other fish and mussel biomarkers showed no significant exposure effects in 2009. The mussel bioaccumulation data in 2009 indicated a lower exposure to the PW effluent than seen previously in 2008 and 2006, resulting in an associated general improvement in the health of the caged mussels. This was due to the reduction in overall discharge of PW components (measured as oil in water) into the area in 2009 compared to previous years as a result of the improved PW treatment system.

  20. Oxygen desaturations triggered by partial seizures: implications for cardiopulmonary instability in epilepsy

    NASA Technical Reports Server (NTRS)

    Blum, A. S.; Ives, J. R.; Goldberger, A. L.; Al-Aweel, I. C.; Krishnamurthy, K. B.; Drislane, F. W.; Schomer, D. L.

    2000-01-01

    PURPOSE: The occurrence of hypoxemia in adults with partial seizures has not been systematically explored. Our aim was to study in detail the temporal dynamics of this specific type of ictal-associated hypoxemia. METHODS: During long-term video/EEG monitoring (LTM), patients underwent monitoring of oxygen saturation using a digital Spo2 (pulse oximeter) transducer. Six patients (nine seizures) were identified with oxygen desaturations after the onset of partial seizure activity. RESULTS: Complex partial seizures originated from both left and right temporal lobes. Mean seizure duration (+/-SD) was 73 +/- 18 s. Mean Spo2 desaturation duration was 76 +/- 19 s. The onset of oxygen desaturation followed seizure onset with a mean delay of 43 +/- 16 s. Mean (+/-SD) Spo2 nadir was 83 +/- 5% (range, 77-91%), occurring an average of 35 +/- 12 s after the onset of the desaturation. One seizure was associated with prolonged and recurrent Spo2 desaturations. CONCLUSIONS: Partial seizures may be associated with prominent oxygen desaturations. The comparable duration of each seizure and its subsequent desaturation suggests a close mechanistic (possibly causal) relation. Spo2 monitoring provides an added means for seizure detection that may increase LTM yield. These observations also raise the possibility that ictal ventilatory dysfunction could play a role in certain cases of sudden unexpected death in epilepsy in adults with partial seizures.

  1. Electrolyte effects in a model of proton discharge on charged electrodes

    NASA Astrophysics Data System (ADS)

    Wiebe, Johannes; Kravchenko, Kateryna; Spohr, Eckhard

    2015-01-01

    We report results on the influence of NaCl electrolyte dissolved in water on proton discharge reactions from aqueous solution to charged platinum electrodes. We have extended a recently developed combined proton transfer/proton discharge model on the basis of empirical valence bond theory to include NaCl solutions with several different concentrations of cations and anions, both stoichiometric (1:1) compositions and non-stoichiometric ones with an excess of cations. The latter solutions partially screen the electrostatic potential from the surface charge of the negatively charged electrode. 500-1000 trajectories of a discharging proton were integrated by molecular dynamics simulations until discharge occurred, or for at most 1.5 ns. The results show a strong dependence on ionic strength, but only a weak dependence on the screening behavior, when comparing stoichiometric and non-stoichiometric solutions. Overall, the Na+ cations exert a more dominant effect on the discharge reaction, which we argue is likely due to the very rigid arrangements of the cations on the negatively polarized electrode surface. Thus, our model predicts, for the given and very high negative surface charge densities, the fastest discharge reaction for pure water, but obviously cannot take into account the fact that such high charge densities are even more out of reach experimentally than for higher electrolyte concentrations.

  2. Numerical study of He/CF{sub 3}I pulsed discharge used to produce iodine atom in chemical oxygen-iodine laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Jiao; Wang Yanhui; Wang Dezhen

    2013-04-15

    The pulsed discharge for producing iodine atoms from the alkyl and perfluoroalky iodides (CH{sub 3}I, CF{sub 3}I, etc.) is the most efficient method for achieving the pulse operating mode of a chemical oxygen-iodine laser. In this paper, a one-dimensional fluid model is developed to study the characteristics of pulsed discharge in CF{sub 3}I-He mixture. By solving continuity equation, momentum equation, Poisson equation, Boltzmann equation, and an electric circuit equation, the temporal evolution of discharge current density and various discharge products, especially the atomic iodine, are investigated. The dependence of iodine atom density on discharge parameters is also studied. The resultsmore » show that iodine atom density increases with the pulsed width and pulsed voltage amplitude. The mixture ratio of CF{sub 3}I and helium plays a more significant role in iodine atom production. For a constant voltage amplitude, there exists an optimal mixture ratio under which the maximum iodine atom concentration is achieved. The bigger the applied voltage amplitude is, the higher partial pressure of CF{sub 3}I is needed to obtain the maximum iodine atom concentration.« less

  3. Regimes of an atmospheric pressure nanosecond repetitively pulsed discharge for methane partial oxidation

    NASA Astrophysics Data System (ADS)

    Maqueo, P. D. G.; Maier, M.; Evans, M. D. G.; Coulombe, S.; Bergthorson, J. M.

    2018-04-01

    The operation of a nanosecond repetitively pulsed discharge for partial oxidation of CH4 is characterized at atmospheric pressure and room temperature. Two regimes are observed: diffuse and filamentary. The first is a low power regime, characterized by low rotational temperatures around 400 K. The second is much more energetic with rotational temperatures close to 600 K. Both have vibrational temperatures of at least 10 times their rotational temperatures. The average electron number density was determined to be 8.9×1015 and 4.0×1017 cm-3, respectively, showing an increase in the ionization fraction in the more powerful filamentary regime. Results of CH4 conversion to H2, CO, CO2 and C2H6 are presented for the filamentary regime, while the diffuse regime shows no measurable conversion ability. As expected, oxidative mixtures show higher conversion ability than pure CH4. A maximum conversion efficiency of 26.3% and a maximum energy efficiency of 19.7% were reached for the oxidative mixtures.

  4. Alternate Test Procedures to Perform Clean Water Act Monitoring for Region 9

    EPA Pesticide Factsheets

    When performing Clean Water Act monitoring, parties interested in using a method not approved in 40 CFR Part 136 must apply to use the alternate test procedure (ATP) in the Region in which the discharging facility is located.

  5. A prototype of an electric-discharge gas flow oxygen−iodine laser: I. Modeling of the processes of singlet oxygen generation in a transverse cryogenic slab RF discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vagin, N. P.; Ionin, A. A., E-mail: aion@sci.lebedev.ru; Kochetov, I. V.

    The existing kinetic model describing self-sustained and electroionization discharges in mixtures enriched with singlet oxygen has been modified to calculate the characteristics of a flow RF discharge in molecular oxygen and its mixtures with helium. The simulations were performed in the gas plug-flow approximation, i.e., the evolution of the plasma components during their motion along the channel was represented as their evolution in time. The calculations were carried out for the O{sub 2}: He = 1: 0, 1: 1, 1: 2, and 1: 3 mixtures at an oxygen partial pressure of 7.5 Torr. It is shown that, under these conditions,more » volumetric gas heating in a discharge in pure molecular oxygen prevails over gas cooling via heat conduction even at an electrode temperature as low as ~100 K. When molecular oxygen is diluted with helium, the behavior of the gas temperature changes substantially: heat removal begins to prevail over volumetric gas heating, and the gas temperature at the outlet of the discharge zone drops to ~220–230 K at room gas temperature at the inlet, which is very important in the context of achieving the generation threshold in an electric-discharge oxygen−iodine laser based on a slab cryogenic RF discharge.« less

  6. Anaerobic treatment of Tequila vinasses in a CSTR-type digester.

    PubMed

    Méndez-Acosta, Hugo Oscar; Snell-Castro, Raúl; Alcaraz-González, Víctor; González-Alvarez, Víctor; Pelayo-Ortiz, Carlos

    2010-06-01

    Tequila industries in general produce great volumes of effluents with high pollutant loads, which are discharged (untreated or partially treated) into natural receivers, thus causing severe environmental problems. In this contribution, we propose an integrated system as a first step to comply with the Mexican ecological norms and stabilize the anaerobic treatment of Tequila vinasses with main design criteria: simple and easy operation, reduce operating time and associated costs (maintenance), integrated and compact design, minimal cost of set-up, start-up, monitoring and control. This system is composed of a fully instrumented and automated lab-scale CSTR-type digester, on-line measuring devices of key variables (pH, temperature, flow rates, etc.), which are used along with off-line readings of chemical oxygen demand (COD), biogas composition, alkalinity and volatile fatty acids to guarantee the operational stability of the anaerobic digestion process. The system performance was evaluated for 200 days and the experimental results show that even under the influence of load disturbances, it is possible to reduce the COD concentration to 85% in the start-up phase and up to 95% during the normal operation phase while producing a biogas with a methane composition greater than 65%. It is also shown that in order to maintain an efficient treatment, the buffering capacity (given by the alkalinity ratio, alpha = intermediate alkalinity/total alkalinity) must be closely monitored.

  7. Nationwide survey of partial fundoplication in Korea: comparison with total fundoplication.

    PubMed

    Lee, Chang Min; Park, Joong-Min; Lee, Han Hong; Jun, Kyong Hwa; Kim, Sungsoo; Seo, Kyung Won; Park, Sungsoo; Kim, Jong-Han; Kim, Jin-Jo; Han, Sang-Uk

    2018-06-01

    Laparoscopic total fundoplication is the standard surgery for gastroesophageal reflux disease. However, partial fundoplication may be a viable alternative. Here, we conducted a nationwide survey of partial fundoplication in Korea. The Korean Anti-Reflux Surgery study group recorded 32 cases of partial fundoplication at eight hospitals between September 2009 and January 2016. The surgical outcomes and postoperative adverse symptoms in these cases were evaluated and compared with 86 cases of total fundoplication. Anterior partial fundoplication was performed in 20 cases (62.5%) and posterior in 12 (37.5%). In most cases, partial fundoplication was a secondary procedure after operations for other conditions. Half of patients who underwent partial fundoplication had typical symptoms at the time of initial diagnosis, and most of them showed excellent (68.8%), good (25.0%), or fair (6.3%) symptom resolution at discharge. Compared to total fundoplication, partial fundoplication showed no difference in the resolution rate of typical and atypical symptoms. However, adverse symptoms such as dysphagia, difficult belching, gas bloating and flatulence were less common after partial fundoplication. Although antireflux surgery is not popular in Korea and total fundoplication is the primary surgical choice for gastroesophageal reflux disease, partial fundoplication may be useful in certain conditions because it has less postoperative adverse symptoms but similar efficacy to total fundoplication.

  8. Utility of Continuous EEG Monitoring in Noncritically lll Hospitalized Patients.

    PubMed

    Billakota, Santoshi; Sinha, Saurabh R

    2016-10-01

    Continuous EEG (cEEG) monitoring is used in the intensive care unit (ICU) setting to detect seizures, especially nonconvulsive seizures and status epilepticus. The utility and impact of such monitoring in non-ICU patients are largely unknown. Hospitalized patients who were not in an ICU and underwent cEEG monitoring in the first half of 2011 and 2014 were identified. Reason for admission, admitting service (neurologic and nonneurologic), indication for cEEG, comorbid conditions, duration of recording, EEG findings, whether an event/seizure was recorded, and impact of EEG findings on management were reviewed. We evaluated the impact of the year of recording, admitting service, indication for cEEG, and neurologic comorbidity on the yield of recordings based on whether an event was captured and/or a change in antiepileptic drug management occurred. Two hundred forty-nine non-ICU patients had cEEG monitoring during these periods. The indication for cEEG was altered mental status (60.6%), observed seizures (26.5%), or observed spells (12.9%); 63.5% were on neuro-related services. The average duration of recording was 1.8 days. EEG findings included interictal epileptiform discharges (14.9%), periodic lateralized discharges (4%), and generalized periodic discharges (1.6%). Clinical events were recorded in 28.1% and seizures in 16.5%. The cEEG led to a change in antiepileptic drug management in 38.6% of patients. There was no impact of type of admitting service; there was no significant impact of indication for cEEG. In non-ICU patients, cEEG monitoring had a relatively high yield of event/seizures (similar to ICU) and impact on management. Temporal trends, admitting service, and indication for cEEG did not alter this.

  9. Multi-parameter monitoring of a freshwater submarine groundwater discharge in SW Greece

    NASA Astrophysics Data System (ADS)

    Karageorgis, A. P.; Papathanassiou, E.

    2011-12-01

    In 2006, we visited for the first time the area of Kalogria-Stoupa in Peloponnissos, SW Greece, and recorded several submarine groundwater discharges (SGDs), one of which was permanent and very active. The main SGD was easily identified as a wide turbulent gyre (diameter 25-60 m) visible at the sea surface from long distance. Preliminary measurements revealed that freshwater was flowing from the spring at 25 m-depth, and plans for monitoring and potential exploitation were scheduled. The SGD was monitored continuously (measurements every 30 min.) from July 2009 to July 2010 for conductivity, temperature, and flow velocity. An autonomous underwater gamma-ray detector (KATERINA) was used to monitor the radioactivity concentration of radon daughters. During summer, the outflowing water was brackish, with low velocities around 0.2 m s-1. After the first intense rainfalls in mid-October 2009, the SGD emanated steadily low salinity waters (<2), whereas flow velocities exceeded 1.2 m s-1. Estimating that the active discharge area was approx. 1 m2, the spring water discharge varied from 750 to 4.500 m3 h-1 over the year. In May 2010, salinity increased abruptly from 4 to 13 within a few hours, accompanied by a slight decrease of flow velocity. We attribute this change to over-pumping of the carstic aquifer for irrigation in the mainland. Until July 2010, salinity increased furthermore (>20), and then decreased gradually to values ~12. Temperature and salinity variability was very high during some periods, probably due to intense turbulence and in-situ mixing of groundwater and ambient seawater. Radon progenies average activities were proportional to the variations of groundwater discharge, whereas potassium exhibited inverse relationship. The instability of salinity, especially during the summer time, where freshwater would be most needed for irrigation, and in ideal conditions for drinking purposes, terminated any exploitation plans. In mid-July 2011, the SGD without any prior notable decrease of its activity (as seen from the surface gyre), stopped completely any groundwater discharge. Divers recorded the absence of any signs of groundwater flow, where at the same time other, smaller SGDs continued to operate in the broader area. That SGD was known for many generations, and locals stated it was always active without any gaps. The reasons for the latter phenomenon remain unknown.

  10. 5 years of continuous seismic monitoring of a mountain river in the Pyrenees

    NASA Astrophysics Data System (ADS)

    Diaz, Jordi; Sanchez-Pastor, Pilar S.; Gallart, Josep

    2017-04-01

    The analysis of background seismic noise variations in the proximity of river channels has revealed as a useful tool to monitor river flow, even for modest discharges. Nevertheless, this monitoring is usually carried on using temporal deployments of seismic stations. The CANF seismic broad-band station, acquiring data continuously since 2010 and located inside an old railway tunnel in the Central Pyrenees, at about 400 m of the Aragón River channel, provides an excellent opportunity to enlarge this view and present a long term monitoring of a mountain river. Seismic signals in the 2-10 Hz band clearly related to river discharges have been identified in the seismic records. Discharge increases due to rainfall, large storms resulting in floods and snowmelt periods can be discriminated from the analysis of the seismic data. Up to now, two large rainfall events resulting in large discharge and damaging floods have been recorded, both sharing similar properties which can be used to implement automatic procedures to identify seismically potentially damaging floods. Another natural process that can be characterized using continuouly acquired seismic data is mountain snowmelt, as this process results in characteristic discharge patterns which can be identified in the seismic data. The time occurrence and intensity of the snowmelt stages for each season can be identified and the 5 seasons available so far compared to detect possible trends The so-called fluvial seismology can also provide important clues to evaluate the beadload transport in rivers, an important parameter to evaluate erosion rates in mountain environments. Analyzing both the amplitude and frequency variations of the seismic data and its hysteresis cycles, it seems possible to estimate the relative contribution of water flow and bedload transport to the seismic signal. The available results suggest that most of the river-generated seismic signal seems related to bed load transportation, while water turbulence is only significant above a discharge thres.hold Since 2015 we are operating 2 additional stations located beside the Cinca and Segre Rivers, also in the Pyrenean range. First results confirm that the river-generated signal can also be identified at these sites, although wind-related signals are recorded in a close frequency band and hence some further analysis is required to discern between both processes. (Founding: MISTERIOS project, CGL2013-48601-C2-1-R)

  11. The influence of negative ions in helium-oxygen barrier discharges: III. Simulation of laser photodetachment and comparison with experiment

    NASA Astrophysics Data System (ADS)

    Nemschokmichal, Sebastian; Tschiersch, Robert; Meichsner, Jürgen

    2017-11-01

    The laser photodetachment experiment in a diffuse helium-oxygen barrier discharge is evaluated by a 1D fluid simulation. As in the experiment, the simulated discharge operates in helium with 400 {ppm} oxygen admixture at 500 {mbar} inside a discharge gap of 3 {mm}. The laser photodetachment is included by the interaction of negative ions with a temporally and spatially dependent photon flux. The simulation with the usually applied set of reactions and rate coefficients provides a much lower negative ion density than needed to explain the impact on the discharge characteristics in the experiment. Further processes for an enhanced negative ion formation and their capabilities of reproducing the experimental results are discussed. These further processes are additional attachment processes in the volume and the negative ion formation at the negatively charged dielectric. Both approaches are able to reproduce the measured laser photodetachment effect partially, but the best agreement with the experimental results is achieved with the formation of negative ions at the negatively charged dielectric.

  12. Citizens' Guide to Biomonitoring in the Great Lakes and St. Lawrence River.

    ERIC Educational Resources Information Center

    Great Lakes United, Buffalo, NY.

    The purpose of this report is to present the issues surrounding biomonitoring of wastewaters discharged into the Great Lakes Basin. Biomonitoring is the process of using organisms to monitor the toxicity of a substance. The report reflects an interest in seeing zero discharge of toxic pollutants in the Great Lakes region. The report is organized…

  13. Feeding preterm infants after hospital discharge: a commentary by the ESPGHAN Committee on Nutrition.

    PubMed

    Aggett, Peter J; Agostoni, Carlo; Axelsson, Irene; De Curtis, Mario; Goulet, Olivier; Hernell, Olle; Koletzko, Berthold; Lafeber, Harry N; Michaelsen, Kim F; Puntis, John W L; Rigo, Jacques; Shamir, Raanan; Szajewska, Hania; Turck, Dominique; Weaver, Lawrence T

    2006-05-01

    Survival of small premature infants has markedly improved during the last few decades. These infants are discharged from hospital care with body weight below the usual birth weight of healthy term infants. Early nutrition support of preterm infants influences long-term health outcomes. Therefore, the ESPGHAN Committee on Nutrition has reviewed available evidence on feeding preterm infants after hospital discharge. Close monitoring of growth during hospital stay and after discharge is recommended to enable the provision of adequate nutrition support. Measurements of length and head circumference, in addition to weight, must be used to identify those preterm infants with poor growth that may need additional nutrition support. Infants with an appropriate weight for postconceptional age at discharge should be breast-fed when possible. When formula-fed, such infants should be fed regular infant formula with provision of long-chain polyunsaturated fatty acids. Infants discharged with a subnormal weight for postconceptional age are at increased risk of long-term growth failure, and the human milk they consume should be supplemented, for example, with a human milk fortifier to provide an adequate nutrient supply. If formula-fed, such infants should receive special postdischarge formula with high contents of protein, minerals and trace elements as well as an long-chain polyunsaturated fatty acid supply, at least until a postconceptional age of 40 weeks, but possibly until about 52 weeks postconceptional age. Continued growth monitoring is required to adapt feeding choices to the needs of individual infants and to avoid underfeeding or overfeeding.

  14. Merging Satellite Optical Sensors and Radar Altimetry for Daily River Discharge Estimation

    NASA Astrophysics Data System (ADS)

    Tarpanelli, A.; Santi, E. S.; Tourian, M. J.; Filippucci, P.; Amarnath, G.; Brocca, L.; Benveniste, J.

    2017-12-01

    River discharge is a fundamental physical variable of the hydrological cycle and notwithstanding its importance the monitoring of the flow in many parts of the Earth is still an open issue. Satellite sensors have great potential in offering new ways to monitor river discharge, because they guarantees regular, uniform and global measurements for long period thanks to the large number of satellites launched during the last twenty-five years. The multi-mission approach has been becoming a useful tool to integrate measurements and intensify the number of samples in space and time. In this study, we investigated the possibility to merge data from optical, i.e. Near InfraRed bands (from MODIS, MERIS, Landsat, and OLCI) and altimetry data (from Topex-Poseidon, Envisat/RA-2, Jason-2, SARAL/AltiKa and CryoSat-2) for estimating daily river discharge in Nigeria and Italy. The merging procedure is carried out by using artificial neural networks. Regarding the optical sensors, results are more affected by the temporal resolution than the spatial resolution. Landsat fails in the estimation of extreme events missing most of the peak values because of the long revisit time (14-16 days). Better performances are obtained with the Near InfraRed bands from MODIS and MERIS that give similar results in river discharge estimation. Finally, the multi-mission approach involving also radar altimetry data is found to be the most reliable tool to estimate river discharge in medium to large rivers.

  15. Idaho National Laboratory Vadose Zone Research Park Geohydrological Monitoring Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kristine Baker

    2006-01-01

    Vadose zone lithology, hydrological characterization of interbed sediments, and hydrological data from subsurface monitoring of Idaho Nuclear Technology and Engineering Center wastewater infiltration are presented. Three-dimensional subsurface lithology of the vadose zone beneath the Vadose Zone Research Park is represented in a 2 dimensional (2 D) diagram showing interpolated lithology between monitoring wells. Laboratory-measured values for saturated hydraulic conductivity and porosity are given for three major interbeds, denoted as the B BC interbed (20 to 35 m bls), the C D interbed (40 to 45 m bls), and the DE 1 2 interbed (55 to 65 m bls), along withmore » an overall physical description of the sediments and geologic depositional environments. Pre-operational pore water pressure conditions are presented to show the presence and location of perched water zones before pond discharge at the New Percolation Ponds. Subsurface infiltration conditions during initial high-volume discharge are presented to show water arrival times and arrival sequences. Steady-state conditions are then presented to show formation and locations of perched water zones and recharge sources after several months of discharge to the New Percolation Ponds.« less

  16. Fiber-Optic Based Compact Gas Leak Detection System

    NASA Technical Reports Server (NTRS)

    deGroot, Wim A.

    1995-01-01

    A propellant leak detection system based on Raman scattering principles is introduced. The proposed system is flexible and versatile as the result of the use of optical fibers. It is shown that multiple species can be monitored simultaneously. In this paper oxygen, nitrogen, carbon monoxide, and hydrogen are detected and monitored. The current detection sensitivity for both hydrogen and carbon monoxide is 1% partial pressure at ambient conditions. The sensitivity for oxygen and nitrogen is 0.5% partial pressure. The response time to changes in species concentration is three minutes. This system can be used to monitor multiple species at several locations.

  17. Optical Characteristics of a Gas Discharge Plasma Based on a Mixture of Mercury Diiodide Vapor, Nitrogen, and Helium

    NASA Astrophysics Data System (ADS)

    Malinina, A. A.; Malinin, A. N.

    2016-09-01

    The results of studies of spectral, temporal, and energy characteristics of radiation in a gas discharge plasma based on a mixture of mercury diiodide vapor with helium and nitrogen in the spectral range of 350-800 nm are presented. Plasma was produced by a barrier discharge in a device with a cylindrical aperture. The electrodes 0.2 m in length were placed at a distance of 0.015 m. The amplitude of the pump pulses, their duration, and frequency were equal to 20-30 kV, 150 ns, and 1-20 kHz, respectively. Radiation of mercury monoiodide exciplex molecules was revealed in the visible spectra region. Dependences of the plasma optical characteristics on the partial pressures of the mixture components were established.

  18. Streamflow and Selected Precipitation Data for Yucca Mountain Region, Southern Nevada and Eastern California, Water Years 1986-90

    USGS Publications Warehouse

    Kane, Thomas G.; Bauer, David J.; Martinez, Clair M.

    1994-01-01

    Streamflow and precipitation data collected at and near Yucca Mountain, Nevada, during water years 1986-90 are presented in this report. The data were collected and compiled as part of the studies by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, to characterize surface-water hydrology in the Yucca Mountain area. Streamflow data include daily-mean discharges and peak discharges at 5 continuous-record gaging stations, and peak discharges at 10 crest-stage, partial-record stations and 2 miscellaneous sites. Precipitation data include cumulative totals at 20 stations maintained by the U.S. Geological Survey and daily totals at 15 stations maintained by the Weather Service Nuclear Support Office, National Oceanic and Atmospheric Administration.

  19. Redox reactions with empirical potentials: atomistic battery discharge simulations.

    PubMed

    Dapp, Wolf B; Müser, Martin H

    2013-08-14

    Batteries are pivotal components in overcoming some of today's greatest technological challenges. Yet to date there is no self-consistent atomistic description of a complete battery. We take first steps toward modeling of a battery as a whole microscopically. Our focus lies on phenomena occurring at the electrode-electrolyte interface which are not easily studied with other methods. We use the redox split-charge equilibration (redoxSQE) method that assigns a discrete ionization state to each atom. Along with exchanging partial charges across bonds, atoms can swap integer charges. With redoxSQE we study the discharge behavior of a nano-battery, and demonstrate that this reproduces the generic properties of a macroscopic battery qualitatively. Examples are the dependence of the battery's capacity on temperature and discharge rate, as well as performance degradation upon recharge.

  20. Determinants of hemoglobin A1c level in patients with type 2 diabetes after in-hospital diabetes education: A study based on continuous glucose monitoring.

    PubMed

    Torimoto, Keiichi; Okada, Yosuke; Sugino, Sachiko; Tanaka, Yoshiya

    2017-05-01

    We investigated the relationship between blood glucose profile at hospital discharge, evaluated by continuous glucose monitoring (CGM), and hemoglobin A1c (HbA1c) level at 12 weeks after discharge in patients with type 2 diabetes who received inpatient diabetes education. This was a retrospective study. The participants were 54 patients with type 2 diabetes who did not change their medication after discharge. The mean blood glucose (MBG), standard deviation, coefficient of variation, mean postprandial glucose excursion, maximum blood glucose, minimum blood glucose, percentage of time with blood glucose at ≥180 mg/dL (time at ≥180), percentage of time with blood glucose at ≥140 mg/dL, and percentage of time with blood glucose at <70 mg/dL were measured at admission and discharge using CGM. The primary end-point was the relationship between CGM parameters and HbA1c level at 12 weeks after discharge. The HbA1c level at 12 weeks after discharge correlated with MBG level (r = 0.30, P = 0.029). Multivariate analysis showed that MBG level and disease duration were predictors of 12-week HbA1c level. Multivariate logistic regression analysis was carried out considering goal achievement as a HbA1c level <7.0% 12 weeks after discharge. Disease duration and time at ≥180 were associated with goal achievement. The present results suggested that blood glucose profile at discharge using CGM seems useful to predict HbA1c level after discharge in patients with type 2 diabetes who received inpatient diabetes education. Early treatment to improve MBG level, as well as postprandial hyperglycemia, is important to achieve strict glycemic control. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  1. Groundwater Discharge along a Channelized Coastal Plain Stream

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaSage, Danita M; Sexton, Joshua L; Mukherjee, Abhijit

    In the Coastal Plain of the southeastern USA, streams have commonly been artificially channelized for flood control and agricultural drainage. However, groundwater discharge along such streams has received relatively little attention. Using a combination of stream- and spring-flow measurements, spring temperature measurements, temperature profiling along the stream-bed, and geologic mapping, we delineated zones of diffuse and focused discharge along Little Bayou Creek, a channelized, first-order perennial stream in western Kentucky. Seasonal variability in groundwater discharge mimics hydraulic-head fluctuations in a nearby monitoring well and spring-discharge fluctuations elsewhere in the region, and is likely to reflect seasonal variability in recharge. Diffusemore » discharge occurs where the stream is incised into the semi-confined regional gravel aquifer, which is comprised of the Mounds Gravel. Focused discharge occurs upstream where the channel appears to have intersected preferential pathways within the confining unit. Seasonal fluctuations in discharge from individual springs are repressed where piping results in bank collapse. Thereby, focused discharge can contribute to the morphological evolution of the stream channel.« less

  2. 40 CFR 469.13 - Monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of my knowledge and belief, no dumping of concentrated toxic organics into the wastewaters has... implementing the solvent management plan submitted to the permitting authority.” (b) In requesting that no monitoring of TTO be required, the direct discharger shall submit a solvent management plan that specifies to...

  3. 40 CFR 469.13 - Monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of my knowledge and belief, no dumping of concentrated toxic organics into the wastewaters has... implementing the solvent management plan submitted to the permitting authority.” (b) In requesting that no monitoring of TTO be required, the direct discharger shall submit a solvent management plan that specifies to...

  4. 40 CFR 469.13 - Monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of my knowledge and belief, no dumping of concentrated toxic organics into the wastewaters has... implementing the solvent management plan submitted to the permitting authority.” (b) In requesting that no monitoring of TTO be required, the direct discharger shall submit a solvent management plan that specifies to...

  5. Universal trace pollutant detector for aircraft monitoring of the ozone layer and industrial areas

    NASA Technical Reports Server (NTRS)

    Filiouguine, I. V.; Kostiouchenko, S. V.; Koudriavtsev, N. N.

    1994-01-01

    A method of monitoring the trace impurities of nitrogen oxides based on controlling of luminescence of NO molecules excited by nanosecond gas discharge have been developed having pptv-ppbv sensitivity and temporal resolution less than 0.01 s.

  6. Quality of surface water in Missouri, water year 2012

    USGS Publications Warehouse

    Barr, Miya N.

    2014-01-01

    The U.S. Geological Survey, in cooperation with the Missouri Department of Natural Resources, designed and operates a series of monitoring stations on streams and springs throughout Missouri known as the Ambient Water-Quality Monitoring Network. During the 2012 water year (October 1, 2011, through September 30, 2012), data were collected at 81 stations—73 Ambient Water-Quality Monitoring Network stations, 6 alternate Ambient Water-Quality Monitoring Network stations, and 2 U.S. Geological Survey National Stream Quality Accounting Network stations. Dissolved oxygen, specific conductance, water temperature, suspended solids, suspended sediment, fecal coliform bacteria, Escherichia coli bacteria, dissolved nitrate plus nitrite as nitrogen, total phosphorus, dissolved and total recoverable lead and zinc, and select pesticide compound summaries are presented for 78 of these stations. The stations primarily have been classified into groups corresponding to the physiography of the State, primary land use, or unique station types. In addition, a summary of hydrologic conditions in the State including peak discharges, monthly mean discharges, and 7-day low flow is presented.

  7. Water-quality control, monitoring and wastewater treatment in Lithuania 1950 to 1999.

    PubMed

    Cetkauskaite, A; Zarkov, D; Stoskus, L

    2001-08-01

    The Lithuanian water-management system developed on the basis of Soviet regulations in 1950-1990. Surface-water quality monitoring started in the 1950s, and the system was improved in the 1960s. Today, 48 rivers are being monitored using up to 70 parameters. Statutory monitoring of discharges started in 1962, wastewater standards were issued in 1957 and 1966, and then revised in 1996. Wastewater-treatment plants were built first in rural areas, in factories since the 1950s, and later in towns. Since 1991, large capacity municipal plants have been constructed with foreign assistance. Water quality has improved in some rivers since 1970, but Lithuania's main river, Nemunas, remains moderately polluted. The lower Nemunas is especially affected by discharges of municipal and industrial wastewater from Sovietsk and Neman (Russia), which account for half of the total loading. Hydrobiological data of 1994-1998 indicated the eutrophication of the Curonian Lagoon, and bacteriological pollution and blue-green algae blooms in the Baltic Sea north of Klaipeda.

  8. Quality of surface water in Missouri, water year 2013

    USGS Publications Warehouse

    Barr, Miya N.; Schneider, Rachel E.

    2014-01-01

    The U.S. Geological Survey, in cooperation with the Missouri Department of Natural Resources, designed and operates a series of monitoring stations on streams and springs throughout Missouri known as the Ambient Water-Quality Monitoring Network. During the 2013 water year (October 1, 2012, through September 30, 2013), data were collected at 79 stations—73 Ambient Water-Quality Monitoring Network stations, 4 alternate Ambient Water-Quality Monitoring Network stations, and 2 U.S. Geological Survey National Stream Quality Accounting Network stations. Dissolved oxygen, specific conductance, water temperature, suspended solids, suspended sediment, Escherichia coli bacteria, fecal coliform bacteria, dissolved nitrate plus nitrite as nitrogen, total phosphorus, dissolved and total recoverable lead and zinc, and select pesticide compound summaries are presented for 76 of these stations. The stations primarily have been classified into groups corresponding to the physiography of the State, primary land use, or unique station types. In addition, a summary of hydrologic conditions in the State including peak discharges, monthly mean discharges, and 7-day low flow is presented.

  9. Which lesson can be learnt from a historical contamination analysis of the most polluted river in Europe?

    PubMed

    Lofrano, Giusy; Libralato, Giovanni; Acanfora, Floriana Giuseppina; Pucci, Luca; Carotenuto, Maurizio

    2015-08-15

    The Sarno River trend analysis during the last 60 years was traced focusing on the socio-economic and environmental issues. The river, originally worshiped as a god by Romans, is affected by an extreme level of environmental degradation, being sadly reputed as the most polluted river in Europe. This is the "not to be followed" example of the worst way a European river can be managed. Data about water, sediment, soil, biota and air contamination were collected from scientific papers, monitoring surveys, and technical reports depicting a sick river. Originally, the river was reputed as a source of livelihood, now it is considered a direct threat for human health. Wastewater can still flow through the river partially or completely untreated, waste production associated with the manufacture of metal products and leather tanning continues to suffer from the historical inadequacy of regional wastewater treatment plants (WWTPs), associated with the partial or no reuse of effluents. All efforts should be devoted to solving the lack of wastewater and waste management, the gap in land planning, improving the capacity of existing WWTPs also via the construction of new sewer sections, restoring Sarno River minimum vital-flow, keeping to a minimum uncontrolled discharges as well as supporting river contracts. The 2015 goal stated by the Water Framework Directive (2000/60/EC) is still far to be reached. The lesson has not been learnt yet. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Muscle hypertrophy with complex repetitive discharges in C-6 radiculopathy.

    PubMed

    Rousseff, Rossen T; Tzvetanov, Plamen

    2005-08-01

    To report on a case of post-denervation muscle hypertrophy in an unusual distribution. A 52-year-old patient with severe flaccid paraparesis after polio developed unilateral C-6 radiculopathy that resolved with conservative treatment. Within 2 years marked hypertrophy, stiffness and pain in the muscles in the affected myotome developed. EMG discovered abundant complex repetitive discharges (CRD) within hypertrophic muscles. On biopsy, true hypertrophy of muscle fibers and some group atrophy was found. Steroid treatment relieved the symptoms and significantly suppressed the CRD. The possible causative role of CRD for hypertrophy in partially denervated muscle is discussed.

  11. Real-time monitoring system for improving corona electrostatic separation in the process of recovering waste printed circuit boards.

    PubMed

    Li, Jia; Zhou, Quan; Xu, Zhenming

    2014-12-01

    Although corona electrostatic separation is successfully used in recycling waste printed circuit boards in industrial applications, there are problems that cannot be resolved completely, such as nonmetal particle aggregation and spark discharge. Both of these problems damage the process of separation and are not easy to identify during the process of separation in industrial applications. This paper provides a systematic study on a real-time monitoring system. Weight monitoring systems were established to continuously monitor the separation process. A Virtual Instrumentation program written by LabVIEW was utilized to sample and analyse the mass increment of the middling product. It includes four modules: historical data storage, steady-state analysis, data computing and alarm. Three kinds of operating conditions were used to verify the applicability of the monitoring system. It was found that the system achieved the goal of monitoring during the separation process and realized the function of real-time analysis of the received data. The system also gave comprehensible feedback on the accidents of material blockages in the feed inlet and high-voltage spark discharge. With the warning function of the alarm system, the whole monitoring system could save the human cost and help the new technology to be more easily applied in industry. © The Author(s) 2014.

  12. Water Resources Data, Georgia, 2001, Volume 2: Continuous ground-water level data, and periodic surface-water- and ground-water-quality data, Calendar Year 2001

    USGS Publications Warehouse

    Coffin, Robert; Grams, Susan C.; Cressler, Alan M.; Leeth, David C.

    2001-01-01

    Water resources data for the 2001 water year for Georgia consists of records of stage, discharge, and water quality of streams; and the stage and contents of lakes and reservoirs published in two volumes in a digital format on a CD-ROM. Volume one of this report contains water resources data for Georgia collected during water year 2001, including: discharge records of 133 gaging stations; stage for 144 gaging stations; precipitation for 58 gaging stations; information for 19 lakes and reservoirs; continuous water-quality records for 17 stations; the annual peak stage and annual peak discharge for 76 crest-stage partial-record stations; and miscellaneous streamflow measurements at 27 stations, and miscellaneous water-quality data recorded by the NAWQA program in Georgia. Volume two of this report contains water resources data for Georgia collected during calendar year 2001, including continuous water-level records of 159 ground-water wells and periodic records at 138 water-quality stations. These data represent that part of the National Water Data System collected by the U.S. Geological Survey and cooperating State and Federal agencies in Georgia. Note: Historically, this report was published as a paper report. For the 1999 and subsequent water-year reports, the Water Resources Data for Georgia changed to a new, more informative and functional format on CD-ROM. The format is based on a geographic information system (GIS) user interface that allows the user to view map locations of the hydrologic monitoring stations and networks within respective river basins. To obtain a copy of the CD version of this report, you may call the U.S. Geological Survey office in Atlanta at (770) 903-9100, or send e-mail to request the publication. Please include your name and mailing address in your e-mail.

  13. The monitoring and verification of nuclear weapons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garwin, Richard L., E-mail: RLG2@us.ibm.com

    2014-05-09

    This paper partially reviews and updates the potential for monitoring and verification of nuclear weapons, including verification of their destruction. Cooperative monitoring with templates of the gamma-ray spectrum are an important tool, dependent on the use of information barriers.

  14. Purus River suspended sediment variability and contributions to the Amazon River from satellite data (2000-2015)

    NASA Astrophysics Data System (ADS)

    Santos, Andre Luis Martinelli Real dos; Martinez, Jean Michel; Filizola, Naziano Pantoja; Armijos, Elisa; Alves, Luna Gripp Simões

    2018-01-01

    The Purus River is one of the major tributaries of Solimões River in Brazil, draining an area of 370,091 km2 and stretching over 2765 km. Unlike those of the other main tributaries of the Amazon River, the Purus River's sediment discharge is poorly characterized. In this study, as an alternative to the logistic difficulties and considering high monitoring costs, we report an experiment where field measurement data and 2700 satellite (MODIS) images are combined to retrieve both seasonal and interannual dynamics in terms of the Purus river sediment discharge near its confluence with the Solimões River. Field radiometric and hydrologic measurements were acquired during 18 sampling trips, including 115 surface water samples and 61 river discharge measurements. Remote sensing reflectance gave important results in the red and infrared levels. They were very well correlated with suspended sediment concentration. The values of R2 are greater than 0.8 (red band) and 0.9 (NIR band). A retrieval algorithm based on the reflectance in both the red and the infrared was calibrated using the water samples collected for the determination of the surface-suspended sediment concentration (SSS). The algorithm was used to calculate 16 years of SSS time series with MODIS images at the Purus River near its confluence with the Solimões River. Results from satellite data correlated with in situ SSS values validate the use of satellite data to be used as a tool to monitor SSS in the Purus River. We evidenced a very short and intense sediment discharge pulse with 55% of the annual sediment budget discharged during the months of January and February. Using river discharge records, we calculated the mean annual sediment discharge of the Purus River at about of 17 Mt·yr-1.

  15. 40 CFR 469.13 - Monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... with the permit limitation for total toxic organics (TTO), I certify that, to the best of my knowledge... management plan submitted to the permitting authority.” (b) In requesting that no monitoring of TTO be required, the direct discharger shall submit a solvent management plan that specifies to the permitting...

  16. 40 CFR 437.4 - Monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compliance monitoring is required for each regulated parameter. (b) Any CWT facility that discharges... wastestream subcategory limitations or standards, it is only subject to one subpart. (3) When a CWT facility treats any waste receipt that contains cyanide at a concentration higher than 136 mg/L, the CWT facility...

  17. 40 CFR 437.4 - Monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... compliance monitoring is required for each regulated parameter. (b) Any CWT facility that discharges... wastestream subcategory limitations or standards, it is only subject to one subpart. (3) When a CWT facility treats any waste receipt that contains cyanide at a concentration higher than 136 mg/L, the CWT facility...

  18. Drain placement can be safely omitted after the majority of robotic partial nephrectomies.

    PubMed

    Abaza, Ronney; Prall, David

    2013-03-01

    Drain placement after partial nephrectomy is considered standard but it is based on routine and not on evidence. With experience we performed robotic partial nephrectomy and routinely omitted a drain even with significant collecting system violation. We have rarely used drains after robotic partial nephrectomy for several years, and we report our outcomes. We reviewed a single surgeon, prospective database of all robotic partial nephrectomies from February 2008 to March 2012, including the characteristics of those with and without a drain. The 150 patients underwent a total of 160 robotic partial nephrectomy procedures with a drain used in 11 patients and omitted in 93%. Mean patient age was 57 years (range 22 to 89), mean American Society of Anesthesiologists score was 2.8 (range 2 to 4) and mean body mass index was 32 kg/m(2) (range 18 to 54). Values were similar in patients with and without a drain. In patients without a drain and in those with a drain mean tumor size was 3.5 cm (range 1.0 to 11.0) and 4.6 cm (range 1.1 to 8.6), and mean R.E.N.A.L. (radius, exophytic/endophytic, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines, hilar tumor touching main renal artery or vein) nephrometry score was 7.8 (range 4 to 12) and 8.8 (range 6 to 11), respectively. Collecting system violation occurred in 88 patients (59%), including 78 without a drain. Two patients (1.3%) required transfusion with no intervention for bleeding. All except 5 patients (97%) were discharged home on postoperative day 1 with all drains removed before discharge. In 2 patients (1.3%) without a drain small urinomas without infection developed more than 2 weeks postoperatively, which were treated with a week of Foley catheter drainage and percutaneous drainage, respectively. Drain placement after robotic partial nephrectomy can be routinely omitted with a low rate of urine leaks, which can be managed safely when they rarely occur. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Temporal lobe interictal epileptic discharges affect cerebral activity in “default mode” brain regions

    PubMed Central

    Laufs, Helmut; Hamandi, Khalid; Salek-Haddadi, Afraim; Kleinschmidt, Andreas K; Duncan, John S; Lemieux, Louis

    2007-01-01

    A cerebral network comprising precuneus, medial frontal, and temporoparietal cortices is less active both during goal-directed behavior and states of reduced consciousness than during conscious rest. We tested the hypothesis that the interictal epileptic discharges affect activity in these brain regions in patients with temporal lobe epilepsy who have complex partial seizures. At the group level, using electroencephalography-correlated functional magnetic resonance imaging in 19 consecutive patients with focal epilepsy, we found common decreases of resting state activity in 9 patients with temporal lobe epilepsy (TLE) but not in 10 patients with extra-TLE. We infer that the functional consequences of TLE interictal epileptic discharges are different from those in extra-TLE and affect ongoing brain function. Activity increases were detected in the ipsilateral hippocampus in patients with TLE, and in subthalamic, bilateral superior temporal and medial frontal brain regions in patients with extra-TLE, possibly indicating effects of different interictal epileptic discharge propagation. PMID:17133385

  20. Heated probe diagnostic inside of the gas aggregation nanocluster source

    NASA Astrophysics Data System (ADS)

    Kolpakova, Anna; Shelemin, Artem; Kousal, Jaroslav; Kudrna, Pavel; Tichy, Milan; Biederman, Hynek; Surface; Plasma Science Team

    2016-09-01

    Gas aggregation cluster sources (GAS) usually operate outside common working conditions of most magnetrons and the size of nanoparticles created in GAS is below that commonly studied in dusty plasmas. Therefore, experimental data obtained inside the GAS are important for better understanding of process of nanoparticles formation. In order to study the conditions inside the gas aggregation chamber, special ``diagnostic GAS'' has been constructed. It allows simultaneous monitoring (or spatial profiling) by means of optical emission spectroscopy, mass spectrometry and probe diagnostic. Data obtained from Langmuir and heated probes map the plasma parameters in two dimensions - radial and axial. Titanium has been studied as an example of metal for which the reactive gas in the chamber starts nanoparticles production. Three basic situations were investigated: sputtering from clean titanium target in argon, sputtering from partially pre-oxidized target and sputtering with oxygen introduced into the discharge. It was found that during formation of nanoparticles the plasma parameters differ strongly from the situation without nanoparticles. These experimental data will support the efforts of more realistic modeling of the process. Czech Science Foundation 15-00863S.

  1. West Hackberry Strategic Petroleum Reserve site brine disposal monitoring, Year I report. Volume V. Supporting data for estuarine hydrology, discharge plume analysis, chemical oceanography, biological oceanography, and data management. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRouen, L.R.; Hann, R.W.; Casserly, D.M.

    1983-02-01

    This project centers around the Strategic Petroleum Site (SPR) known as the West Hackberry salt dome which located in southwestern Louisiana, and which is designed to store 241 million barrels of crude oil. Oil storage caverns are formed by injecting water into salt deposits, and pumping out the resulting brine. Studies described in this report were designed as follow-on studies to three months of pre-discharge characterization work, and include data collected during the first year of brine leaching operations. The objectives were to: (1) characterize the environment in terms of physical, chemical and biological attributes; (2) determine if significant adversemore » changes in ecosystem productivity and stability of the biological community are occurring as a result of brine discharge; and (3) determine the magnitude of any change observed. Volume V contains appendices for the following: supporting data for estuarine hydrology and hydrography; supporting data analysis of discharge plume; supporting data for water and sediment chemistry; CTD/DO and pH profiles during biological monitoring; supporting data for nekton; and supporting data for data management.« less

  2. Sediment inflow, outflow and deposition for Lakes Marion and Moultrie, South Carolina, October 1983-March 1985

    USGS Publications Warehouse

    Cooney, T.W.

    1988-01-01

    In 1941 a Coastal Plain reach of the Santee River was impounded to form Lake Marion and diverted into a diked-off part of the Cooper River basin to form Lake Moultrie. Rates of sediment inflow and outflow of the lakes were determined by the U.S. Geological Survey for the periods July 1966 - June 1968 and October 1983 - March 1985. Total sediment discharge was estimated for two inflow stations and continuous streamflow monitors and automatic suspended-sediment samplers were used for computation of suspended-sediment discharge. Bedload discharge was computed by the modified Einstein procedure. Suspended-sediment discharge was monitored at three outflow stations, with the suspended-sediment concentration measured on a weekly basis. During the 1983-1985 study, mean annual suspended-sediment inflow to Lakes Marion and Moultrie was estimated to be 722,000 tons, and the outflow was estimated at 175,000 tons, for a trap efficiency of 76% and a deposition rate of about 547,000 tons/year. This is about 33% less than the deposition rate determined during the 1966-68 study. The deposition rate for suspended and bedload sediment during the 1983 - 1985 study was about 650,000 tons/year. (USGS)

  3. Proglacial River Reveals Substantial Greenland Ice Sheet Climate Sensitivity and Meltwater Routing Delays

    NASA Astrophysics Data System (ADS)

    van As, D.; Mikkelsen, A. B.; Holtegaard Nielsen, M.; Claesson Liljedahl, L.; Lindback, K.; Pitcher, L. H.; Hasholt, B.

    2016-12-01

    A 12.000 km2 area of the Greenland ice sheet discharges meltwater via the proglacial Watson River in west Greenland. In a ten-year time span of continuous monitoring (2006-2015), the river discharged 3.8 km3 to 11.2 km3 yr-1. The large interannual variability is for an important part explained by hypsometric amplification: the flattening of the ice sheet with elevation adds 70% meltwater discharge sensitivity to atmospheric temperature. Comparing river discharge with ice sheet surface meltwater production from an observation-based surface mass balance model we quantify multiple-day routing delays for meltwater transit through the supra-, en-, sub- and proglacial system. This delay increases with ice sheet surface elevation: on average five days for surface water at the previous-known equilibrium line altitude (ELA) of ca. 1550 m, and seven days at the 2009-2015 ELA of ca. 1800 m above sea level. A flooding of the Kangerlussuaq bridge as in July 2012 thus requires a multi-day high-melt episode and can therefore be anticipated by in-situ monitoring of ice sheet melt. No evidence of significant en- or subglacial meltwater retention is found.

  4. Dermal Sensitization of 1-Acetyloctahydro-3,5,7-Trinitro-1,3,5,7-Tetrazocine.

    DTIC Science & Technology

    1984-08-08

    raw data for this study were audited on 29 May 84. Routine inspections with no adverse findings are reported quarterly, thus these inspections are...SEX. Its discharge, while partially mitigated by present and planned polution abatement facilities at HSAAP, will continue and could increase at

  5. RECONSTRUCTION OF CONTAMINANT TRENDS IN A SALT WEDGE ESTUARY WITH SEDIMENT CORES DATED USING A MULTIPLE PROXY APPROACH

    EPA Science Inventory

    The Taunton River is a partially mixed tidal estuary in southeastern Massachusetts (USA) which has received significant contaminant inputs, yet little information exists on the history of discharge and the subsequent fate of these contaminants. Three sediment cores taken along a...

  6. 42 CFR 485.918 - Condition of participation: Organization, governance, administration of services, and partial...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: Community Mental Health Centers (CMHCs) § 485.918 Condition of participation: Organization, governance... individuals, individuals with serious mental illness, and residents of its mental health service area who have been discharged from an inpatient mental health facility. (a) Standard: Governing body and...

  7. ANALYTICAL ASSESSMENT OF THE IMPACTS OF PARTIAL MASS DEPLETION IN DNAPL SOURCE ZONES (SAN FRANCISCO, CA)

    EPA Science Inventory

    Analytical solutions describing the time-dependent DNAPL source-zone mass and contaminant discharge rate are used as a flux-boundary condition in a semi-analytical contaminant transport model. These analytical solutions assume a power relationship between the flow-averaged sourc...

  8. A solar charge and discharge controller for wireless sensor nodes

    NASA Astrophysics Data System (ADS)

    Dang, Yibo; Shen, Shu

    2018-02-01

    Aiming at the energy supply problem that restricts the life of wireless sensor nodes, a solar energy charge and discharge controller suitable for wireless sensor nodes is designed in this paper. A Microcontroller is used as the core of the solar charge and discharge controller. The software of the solar charge and discharge controller adopts the C language to realize the program of the main control module. Firstly, the function of monitoring solar panel voltage and lithium battery voltage are simulated by Protel software, and the charge time is tested in cloudy and overcast outdoor environment. The results of the experiment show that our controller meets the power supply demand of wireless sensor nodes.

  9. Index of surface-water stations in Texas, January 1986

    USGS Publications Warehouse

    Carrillo, E.R.; Buckner, H.D.; Rawson, Jack

    1986-01-01

    As of January 1, 1986, the surface-water data-collection network in Texas operated by the U.S. Geological Survey included 386 streamflow, 87 reservoir-contents, 33 stage, 10 crest-stage partial-record, 8 periodic discharge through range, 38 flood-hydrograph partial-record, 11 flood-profile partial-record , 36 low-flow partial-record 2 tide-level, 45 daily chemical-quality, 23 continuous-recording water-quality, 97 periodic biological, 19 lake surveys, 174 periodic organic- and (or) nutrient, 4 periodic insecticide, 58 periodic pesticide, 22 automatic sampler, 157 periodic minor elements, 141 periodic chemical-quality, 108 periodic physical-organic, 14 continuous-recording three- or four-parameter water-quality, 3 sediment, 39 periodic sediment, 26 continuous-recording temperature, and 37 national stream-quality accounting network stations were in operation. Tables describing the station location, type of data collected, and place where data are available are included, as well as maps showing the location of most of the stations. (USGS)

  10. Interictal epileptic discharge correlates with global and frontal cognitive dysfunction in temporal lobe epilepsy.

    PubMed

    Dinkelacker, Vera; Xin, Xu; Baulac, Michel; Samson, Séverine; Dupont, Sophie

    2016-09-01

    Temporal lobe epilepsy (TLE) with hippocampal sclerosis has widespread effects on structural and functional connectivity and often entails cognitive dysfunction. EEG is mandatory to disentangle interactions in epileptic and physiological networks which underlie these cognitive comorbidities. Here, we examined how interictal epileptic discharges (IEDs) affect cognitive performance. Thirty-four patients (right TLE=17, left TLE=17) were examined with 24-hour video-EEG and a battery of neuropsychological tests to measure intelligence quotient and separate frontal and temporal lobe functions. Hippocampal segmentation of high-resolution T1-weighted imaging was performed with FreeSurfer. Partial correlations were used to compare the number and distribution of clinical interictal spikes and sharp waves with data from imagery and psychological tests. The number of IEDs was negatively correlated with executive functions, including verbal fluency and intelligence quotient (IQ). Interictal epileptic discharge affected cognitive function in patients with left and right TLE differentially, with verbal fluency strongly related to temporofrontal spiking. In contrast, IEDs had no clear effects on memory functions after corrections with partial correlations for age, age at disease onset, disease duration, and hippocampal volume. In patients with TLE of long duration, IED occurrence was strongly related to cognitive deficits, most pronounced for frontal lobe function. These data suggest that IEDs reflect dysfunctional brain circuitry and may serve as an independent biomarker for cognitive comorbidity. Copyright © 2016. Published by Elsevier Inc.

  11. Progress in the development of the neutron flux monitoring system of the French GEN-IV SFR: simulations and experimental validations [ANIMMA--2015-IO-392

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jammes, C.; Filliatre, P.; Izarra, G. de

    France has a long experience of about 50 years in designing, building and operating sodium-cooled fast reactors (SFR) such as RAPSODIE, PHENIX and SUPER PHENIX. Fast reactors feature the double capability of reducing nuclear waste and saving nuclear energy resources by burning actinides. Since this reactor type is one of those selected by the Generation IV International Forum, the French government asked, in the year 2006, CEA, namely the French Alternative Energies and Atomic Energy Commission, to lead the development of an innovative GEN-IV nuclear- fission power demonstrator. The major objective is to improve the safety and availability of anmore » SFR. The neutron flux monitoring (NFM) system of any reactor must, in any situation, permit both reactivity control and power level monitoring from startup to full power. It also has to monitor possible changes in neutron flux distribution within the core region in order to prevent any local melting accident. The neutron detectors will have to be installed inside the reactor vessel because locations outside the vessel will suffer from severe disadvantages; radially the neutron shield that is also contained in the reactor vessel will cause unacceptable losses in neutron flux; below the core the presence of a core-catcher prevents from inserting neutron guides; and above the core the distance is too large to obtain decent neutron signals outside the vessel. Another important point is to limit the number of detectors placed in the vessel in order to alleviate their installation into the vessel. In this paper, we show that the architecture of the NFM system will rely on high-temperature fission chambers (HTFC) featuring wide-range flux monitoring capability. The definition of such a system is presented and the justifications of technological options are brought with the use of simulation and experimental results. Firstly, neutron-transport calculations allow us to propose two in-vessel regions, namely the above-core and under-core structures. We verify that they comply with the main objective, that is the neutron power and flux distribution monitoring. HTFC placed in these two regions can detect an inadvertent control rod withdrawal that is a postulated initiating event for safety demonstration. Secondly, we show that the HTFC reliability is enhanced thanks to a more robust physical design and the fact that it has been justified that the mineral insulation is insensitive to any increase in temperature. Indeed, the HTFC insulation is subject to partial discharges at high temperature when the electric field between their electrodes is greater than about 200 V/mm or so. These discharges give rise to signals similar to the neutron pulses generated by a fission chamber itself, which may bias the HTFC count rate at start-up only. However, as displayed in Figure 1, we have experimentally verified that one can discriminate neutron pulses from partial discharges using online estimation of pulse width. Thirdly, we propose to estimate the count rate of a HTFC using the third order cumulant of its signal that is described by a filtered Poisson process. For such a statistic process, it is known that any cumulant, also called cumulative moment, is proportional to the process intensity that is here the count rate of a fission chamber. One recalls that the so-called Campbelling mode of such a detector is actually based on the signal variance, which is the second-order cumulant as well. The use of this extended Campbelling mode based on the third-order cumulant will permit to ensure the HTFC response linearity over the entire neutron flux range using a signal processing technique that is simple enough to satisfy design constraints on electric devices important for nuclear safety. We also show that this technique, named high order Campbelling method (HOC), is significantly more robust than another technique based on the change in the HTFC filling gas, which consists in adding a few percent of nitrogen. Finally, we also present an experimental campaign devoted to the required calibration process of the so-called HOC method. The Campbelling results show a good agreement with the simple pulse counting estimation at low count rates. It is also shown that the HOC technique provides a linear estimation of the count rates at higher power levels as well.« less

  12. Monitoring nanoparticle synthesis in a carbon arc discharge environment, in situ

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitrani, James

    This work presents experimental and theoretical studies of gas-phase synthesis of fullerenes and carbon nanoparticles in the presence of an atmospheric-pressure, arc discharge plasma. Carbon arc discharges have been used for synthesizing carbon nanotubes for over 25 years, and have the potential for economically synthesizing industrial-scale quantities of fullerenes. However, the efficiency and selectivity of fullerene synthesis with carbon arc discharges are quite low. Optimizing carbon arc discharges for fullerene synthesis requires a thorough understanding of the dynamics behind gas-phase nanoparticle synthesis in the presence of an arc discharge plasma. We built a carbon arc discharge setup to study nanoparticlemore » and fullerene synthesis. The laser-induced incandescence (LII) diagnostic was applied for monitoring nanoparticle synthesis, in situ. The LII diagnostic had previously been applied as a combustion diagnostic for in situ measurements of concentrations and sizes of soot particles in flame environments. Prior to the present study, it had never been applied for studying fullerenes, nor had it been applied to study nanoparticles in the presence of an atmospheric-pressure plasma. Therefore, experiments were designed that allowed for the calibration of the LII diagnostic with research-grade, arc-synthesized soot particles and carbon nanotubes. Additionally, the theory and models underpinning the LII diagnostic were adapted to include the presence of an atmospheric-pressure, arc-discharge plasma. Results presented in this work confirm the ability of the LII diagnostic to measure sizes of arc-synthesized nanoparticles in situ, and show the spatial location of high densities of arc-synthesized nanoparticles with respect to the arc discharge plasma. Determining the spatial location of nanoparticle synthesis and growth is crucial for understanding the background conditions (e.g. background gas temperature, electron densities ...) in which nanoparticles nucleate and grow in the arc discharge environment. Future work would involve combining the LII diagnostic with other laser-based diagnostics (e.g. Rayleigh scattering, laser-induced fluorescence) for a more comprehensive study of gas-phase nanoparticle synthesis and investigating fundamental basic-science questions related to low temperature plasma physics, and laser-nanoparticle interactions.« less

  13. Monitoring Nanoparticle Synthesis in a Carbon Arc Discharge Environment, In Situ

    NASA Astrophysics Data System (ADS)

    Mitrani, James

    This work presents experimental and theoretical studies of gas-phase synthesis of fullerenes and carbon nanoparticles in the presence of an atmospheric-pressure, arc discharge plasma. Carbon arc discharges have been used for synthesizing carbon nanotubes for over 25 years, and have the potential for economically synthesizing industrial-scale quantities of fullerenes. However, the efficiency and selectivity of fullerene synthesis with carbon arc discharges are quite low. Optimizing carbon arc discharges for fullerene synthesis requires a thorough understanding of the dynamics behind gas-phase nanoparticle synthesis in the presence of an arc discharge plasma. We built a carbon arc discharge setup to study nanoparticle and fullerene synthesis. The laser-induced incandescence (LII) diagnostic was applied for monitoring nanoparticle synthesis, in situ. The LII diagnostic had previously been applied as a combustion diagnostic for in situ measurements of concentrations and sizes of soot particles in flame environments. Prior to the present study, it had never been applied for studying fullerenes, nor had it been applied to study nanoparticles in the presence of an atmospheric-pressure plasma. Therefore, experiments were designed that allowed for the calibration of the LII diagnostic with research-grade, arc-synthesized soot particles and carbon nanotubes. Additionally, the theory and models underpinning the LII diagnostic were adapted to include the presence of an atmospheric-pressure, arc-discharge plasma. Results presented in this work confirm the ability of the LII diagnostic to measure sizes of arc-synthesized nanoparticles in situ, and show the spatial location of high densities of arc-synthesized nanoparticles with respect to the arc discharge plasma. Determining the spatial location of nanoparticle synthesis and growth is crucial for understanding the background conditions (e.g. background gas temperature, electron densities ...) in which nanoparticles nucleate and grow in the arc discharge environment. Future work would involve combining the LII diagnostic with other laser-based diagnostics (e.g. Rayleigh scattering, laser-induced fluorescence) for a more comprehensive study of gas-phase nanoparticle synthesis and investigating fundamental basic-science questions related to low temperature plasma physics, and laser-nanoparticle interactions.

  14. Assessing the impacts of dams and levees on the hydrologic record of the Middle and Lower Mississippi River, USA

    USGS Publications Warehouse

    Remo, Jonathan W.F.; Ickes, Brian; Ryherd, Julia K.; Guida, Ross J.; Therrell, Matthew D.

    2018-01-01

    The impacts of dams and levees on the long-term (>130 years) discharge record was assessed along a ~1200 km segment of the Mississippi River between St. Louis, Missouri, and Vicksburg, Mississippi. To aid in our evaluation of dam impacts, we used data from the U.S. National Inventory of Dams to calculate the rate of reservoir expansion at five long-term hydrologic monitoring stations along the study segment. We divided the hydrologic record at each station into three periods: (1) a pre-rapid reservoir expansion period; (2) a rapid reservoir expansion period; and (3) a post-rapid reservoir expansion period. We then used three approaches to assess changes in the hydrologic record at each station. Indicators of hydrologic alteration (IHA) and flow duration hydrographs were used to quantify changes in flow conditions between the pre- and post-rapid reservoir expansion periods. Auto-regressive interrupted time series analysis (ARITS) was used to assess trends in maximum annual discharge, mean annual discharge, minimum annual discharge, and standard deviation of daily discharges within a given water year. A one-dimensional HEC-RAS hydraulic model was used to assess the impact of levees on flood flows. Our results revealed that minimum annual discharges and low-flow IHA parameters showed the most significant changes. Additionally, increasing trends in minimum annual discharge during the rapid reservoir expansion period were found at three out of the five hydrologic monitoring stations. These IHA and ARITS results support previous findings consistent with the observation that reservoirs generally have the greatest impacts on low-flow conditions. River segment scale hydraulic modeling revealed levees can modestly increase peak flood discharges, while basin-scale hydrologic modeling assessments by the U.S. Army Corps of Engineers showed that tributary reservoirs reduced peak discharges by a similar magnitude (2 to 30%). This finding suggests that the effects of dams and levees on peak flood discharges are in part offsetting one another along the modeled river segments and likely other substantially leveed segments of the Mississippi River.

  15. Assessing the impacts of dams and levees on the hydrologic record of the Middle and Lower Mississippi River, USA

    NASA Astrophysics Data System (ADS)

    Remo, Jonathan W. F.; Ickes, Brian S.; Ryherd, Julia K.; Guida, Ross J.; Therrell, Matthew D.

    2018-07-01

    The impacts of dams and levees on the long-term (>130 years) discharge record was assessed along a 1200 km segment of the Mississippi River between St. Louis, Missouri, and Vicksburg, Mississippi. To aid in our evaluation of dam impacts, we used data from the U.S. National Inventory of Dams to calculate the rate of reservoir expansion at five long-term hydrologic monitoring stations along the study segment. We divided the hydrologic record at each station into three periods: (1) a pre-rapid reservoir expansion period; (2) a rapid reservoir expansion period; and (3) a post-rapid reservoir expansion period. We then used three approaches to assess changes in the hydrologic record at each station. Indicators of hydrologic alteration (IHA) and flow duration hydrographs were used to quantify changes in flow conditions between the pre- and post-rapid reservoir expansion periods. Auto-regressive interrupted time series analysis (ARITS) was used to assess trends in maximum annual discharge, mean annual discharge, minimum annual discharge, and standard deviation of daily discharges within a given water year. A one-dimensional HEC-RAS hydraulic model was used to assess the impact of levees on flood flows. Our results revealed that minimum annual discharges and low-flow IHA parameters showed the most significant changes. Additionally, increasing trends in minimum annual discharge during the rapid reservoir expansion period were found at three out of the five hydrologic monitoring stations. These IHA and ARITS results support previous findings consistent with the observation that reservoirs generally have the greatest impacts on low-flow conditions. River segment scale hydraulic modeling revealed levees can modestly increase peak flood discharges, while basin-scale hydrologic modeling assessments by the U.S. Army Corps of Engineers showed that tributary reservoirs reduced peak discharges by a similar magnitude (2 to 30%). This finding suggests that the effects of dams and levees on peak flood discharges are in part offsetting one another along the modeled river segments and likely other substantially leveed segments of the Mississippi River.

  16. A partial pressure monitor and controller for stable ozone flow from a silica gel trap

    NASA Astrophysics Data System (ADS)

    Stevens, R. E.; Hsiao, C.-W.; Le, Linh; Curro, N. J.; Monton, B. J.; Chang, B.-Y.; Kung, C.-Y.; Kittrell, C.; Kinsey, J. L.

    1998-06-01

    A new ozone trapping system designed for safe and consistent delivery to a reaction vessel is described. Silica gel is used to trap the ozone because of its known safety advantages over traps that store ozone in liquid form. The new design is free of any liquid baths, such as freon or flammable solvents. A circuit design for monitoring and controlling the ozone partial pressure of 6-25 Torr is also described.

  17. Sediment motion and velocity in a glacier-fed stream

    NASA Astrophysics Data System (ADS)

    Mao, L.; Dell'Agnese, A.; Comiti, F.

    2017-08-01

    Current understanding of coarse sediment transport (e.g. threshold for motion, travel length and virtual velocity) in mountain rivers is still quite limited, and even less is known about glacial streams. However, the hydrological characteristics of these systems (strong daily discharge fluctuations, high water turbidity) pose challenges to the use of tracers to monitor bed sediment dynamics, as tagged clasts are usually located after bedload events when flow stage has receded, e.g. by means of portable antennas in the case of Passive Integrated Transponders (PIT). The use of stationary antennas, still scarcely in use worldwide, to detect PIT-tagged particles has potential advantages in glacier-fed streams. If water discharge is monitored continuously, a stationary antenna provides real time data on the actual discharge at the moment of tracer particles passage. This study focuses on incipient motion and virtual velocity of bed particles measured by a stationary antennas system in a steep mountain channel (Saldur River, drainage area 18.6 km2, Italian Alps) where significant daily discharge fluctuations and bedload transport occur as a result of a nivo-glacial regime. Four stationary antennas were installed 50-m apart in the study reach. A total of 629 PIT-tagged clasts were inserted in the studied reach between 2011 and 2014, ranging in size from 35 mm to 580 mm, with an overall recovery rate of around 44%. Critical discharge for sediment entrainment was obtained by detecting the movement of tracers placed immediately upstream of antennas. Virtual velocity was derived by knowing distances between the antennas and travel time of tracers. Results on initiation of motion show that the relationship between the size of transported tracers and the discharge measured at the time clasts were passing the stationary antenna is very weak. The influence of antecedent flows on incipient motion was thus investigated by dividing the highest discharge recorded between each PIT deployment and the subsequent entrainment by the actual critical discharge at the time of movement (ratio Qmax/Qc). Results show that approximately 50% of tracers moved at Qmax/Qc ≤ 1.2, and that 73% of tracers moved at Qmax/Qc < 1.5. Therefore, about 30% of tracers had to previously experience a discharge substantially greater than the one that actually mobilized them. Also, coarser particles moved at higher Qmax/Qc ratios, suggesting that higher antecedent flows may be needed to destabilize bed clustering. Results on the virtual velocity of the PIT-tagged clasts employed in the field show that the virtual velocity turned out to be highly variable (ranging from 101 to 10- 5 m min- 1) and weakly related to either particle size or flow discharge. However, virtual velocity was well correlated with the highest flow discharge experienced by each tracer normalized by a percentile of the flow duration curve. This evidence further stresses the importance of flow history on sediment entrainment and transport. Finally, the pros and cons of the deployed monitoring technology are discussed.

  18. 40 CFR 123.45 - Noncompliance and program reporting by the Director.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) WATER PROGRAMS STATE PROGRAM REQUIREMENTS Transfer of Information and Permit Review § 123.45... schedule report for final compliance or a monitoring report. This applies when the permittee has failed to submit a final compliance schedule progress report, pretreatment report, or a Discharge Monitoring Report...

  19. 40 CFR 123.45 - Noncompliance and program reporting by the Director.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) WATER PROGRAMS STATE PROGRAM REQUIREMENTS Transfer of Information and Permit Review § 123.45... schedule report for final compliance or a monitoring report. This applies when the permittee has failed to submit a final compliance schedule progress report, pretreatment report, or a Discharge Monitoring Report...

  20. 40 CFR 123.45 - Noncompliance and program reporting by the Director.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) WATER PROGRAMS STATE PROGRAM REQUIREMENTS Transfer of Information and Permit Review § 123.45... schedule report for final compliance or a monitoring report. This applies when the permittee has failed to submit a final compliance schedule progress report, pretreatment report, or a Discharge Monitoring Report...

  1. 40 CFR 123.45 - Noncompliance and program reporting by the Director.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) WATER PROGRAMS STATE PROGRAM REQUIREMENTS Transfer of Information and Permit Review § 123.45... schedule report for final compliance or a monitoring report. This applies when the permittee has failed to submit a final compliance schedule progress report, pretreatment report, or a Discharge Monitoring Report...

  2. Time series dataset of fish assemblages near thermal discharges at nuclear power plants in northern Taiwan.

    PubMed

    Chen, Hungyen; Chen, Ching-Yi; Shao, Kwang-Tsao

    2018-05-08

    Long-term time series datasets with consistent sampling methods are rather rare, especially the ones of non-target coastal fishes. Here we described a long-term time series dataset of fish collected by trammel net fish sampling and observed by an underwater diving visual census near the thermal discharges at two nuclear power plants on the northern coast of Taiwan. Both experimental and control stations of these two investigations were monitored four times per year in the surrounding seas at both plants from 2000 to 2017. The underwater visual census mainly monitored reef fish assemblages and trammel net samples monitored pelagic or demersal fishes above the muddy/sandy bottom. In total, 508 samples containing 203,863 individuals from 347 taxa were recorded in both investigations at both plants. These data can be used by ecologists and fishery biologists interested in the elucidation of the temporal patterns of species abundance and composition.

  3. Practical Approaches for Assessment of Daily and Post-discharge Room Disinfection in Healthcare Facilities.

    PubMed

    Deshpande, Abhishek; Donskey, Curtis J

    2017-09-01

    Cleaning and disinfection in healthcare facilities is essential to ensure patient safety. This review examines practical strategies used to assess and improve the effectiveness of daily and post-discharge manual cleaning in healthcare facilities. Effective implementation of cleaning interventions requires objective monitoring of staff performance with regular feedback on performance. Use of fluorescent markers to assess thoroughness of cleaning and measurement of residual ATP can provide rapid and objective feedback to personnel and have been associated with improved cleaning. Direct observation of cleaning and interviews with front-line staff are useful to identify variations and deficiencies in practice that may not be detected by other methods. Although not recommended for routine monitoring, cultures can be helpful for outbreak investigations. Monitoring and feedback can be effective in improving cleaning and disinfection in healthcare facilities. Ongoing commitment within institutions is needed to sustain successful cleaning and disinfection programs.

  4. Space radiation studies

    NASA Technical Reports Server (NTRS)

    Gregory, J. C.

    1986-01-01

    Instrument design and data analysis expertise was provided in support of several space radiation monitoring programs. The Verification of Flight Instrumentation (VFI) program at NASA included both the Active Radiation Detector (ARD) and the Nuclear Radiation Monitor (NRM). Design, partial fabrication, calibration and partial data analysis capability to the ARD program was provided, as well as detector head design and fabrication, software development and partial data analysis capability to the NRM program. The ARD flew on Spacelab-1 in 1983, performed flawlessly and was returned to MSFC after flight with unchanged calibration factors. The NRM, flown on Spacelab-2 in 1985, also performed without fault, not only recording the ambient gamma ray background on the Spacelab, but also recording radiation events of astrophysical significance.

  5. Water resources data, Arkansas, 2002

    USGS Publications Warehouse

    Brossett, T.H.; Evans, D.A.

    2003-01-01

    Water resources data for the 2002 water year for Arkansas consist of records of discharge and water quality (physical measurements and chemical concentrations) of streams, water quality of lakes, and groundwater levels and ground-water quality. Data from selected sites in Missouri and Oklahoma also are included. This report contains daily discharge records for 108 surface-water gaging stations and 87 peak-discharge partial-record stations, water-quality data for 65 surface-water stations and 5 wells, and water levels for 15 observation wells. Additional water data were collected at various sites, not part of the systematic data-collection program, and are published as miscellaneous measurements. Note: Historically, this report has been published as a paper report. Beginning with the 2002 water year report, these reports will be available from the World Wide Web at http://ar.water.usgs.gov.

  6. Water Resources Data, Kansas, Water Year 2001

    USGS Publications Warehouse

    Putnam, J.E.; Lacock, D.L.; Schneider, D.R.

    2002-01-01

    Water-resources data for the 2001 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 145 complete-record gaging stations; elevation and contents at 20 lakes and reservoirs; waterquality records at 2 precipitation stations, water-level data at 19 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 11 gaging stations. Also included are discharge data for 26 high-flow partial-record stations, miscellaneous onsite water-quality data collected at 140 stations, and suspended-sediment concentration for 12 stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.

  7. Water Resources Data, Kansas, Water Year 2002

    USGS Publications Warehouse

    Putnam, J.E.; Schneider, D.R.

    2003-01-01

    Water-resources data for the 2002 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 149 complete-record gaging stations; elevation and contents at 20 lakes and reservoirs; waterquality records at 2 precipitation stations, water-level data at 18 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 11 gaging stations. Also included are discharge data for 26 high-flow partial-record stations, miscellaneous onsite water-quality data collected at 142 stations, and suspended-sediment concentration for 12 stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.

  8. Water Resources Data, Kansas, Water Year 2000

    USGS Publications Warehouse

    Putnam, J.E.; Lacock, D.L.; Schneider, D.R.; Carlson, M.D.

    2001-01-01

    Water-resources data for the 2000 water year for Kansas consist of records of stage, discharge, and water quality of streams; elevation and contents of lakes and reservoirs; and water levels of ground-water wells. This report contains records for water discharge at 144 complete-record gaging stations; elevation and contents at 19 lakes and reservoirs; water-quality records at 2 precipitation stations, water-level data at 18 observation wells; and records of specific conductance, pH, water temperature, dissolved oxygen, and turbidity at 8 gaging stations. Also included are discharge data for 26 high-flow partial-record stations, and miscellaneous onsite water-quality data collected at 134 stations, and suspended-sediment concentration for 12 stations. These data represent that part of the National Water Information System collected by the U.S. Geological Survey in cooperation with local, State, and Federal agencies in Kansas.

  9. Evaluation of 20 Ah Li Ion Cells

    NASA Technical Reports Server (NTRS)

    Smart, Marshall; Ratnakumar, B. V.; Huang, Charles K.; Surampudi, S.; Hill, Carole; Radzykewycz, Dan T.; Marsh, Richard A.

    1998-01-01

    Lithium ion cells of 20 Ah capacity were fabricated by Bluestar Advanced Technology Corporation, Canada under a developmental contract from US Air Force. In this paper, we report our studies on the evaluation of these cells under various test conditions. These include generic test conditions such as discharges and charges at different temperatures to understand the rate-limiting processes in the discharge/charge processes as a function of temperature, and cycle life under standard cycling conditions (100% DOD) at ambient temperature. In addition, tests are being done to ascertain the performance of the cells in the Mars 2001 Lander application, which includes pulse testing of the cells at 60 A and 40 A loads for 100 mS and 1 min., respectively at different states of charge and temperatures, and cycling at low temperature at partial depths of discharge.

  10. Hydrogeological characterization of peculiar Apenninic springs

    NASA Astrophysics Data System (ADS)

    Cervi, F.; Marcaccio, M.; Petronici, F.; Borgatti, L.

    2014-09-01

    In the northern Apennines of Italy, springs are quite widespread over the slopes. Due to the outcropping of low-permeability geologic units, they are generally characterized by low-yield capacities and high discharge variability during the hydrologic year. In addition, low-flow periods (discharge lower than 1 Ls-1) reflect rainfall and snowmelt distribution and generally occur in summer seasons. These features strongly condition the management for water-supply purposes, making it particularly complex. The "Mulino delle Vene" springs (420 m a.s.l., Reggio Emilia Province, Italy) are one of the largest in the Apennines for mean annual discharge and dynamic storage and are considered as the main water resource in the area. They flow out from several joints and fractures at the bottom of an arenite rock mass outcrop in the vicinity of the Tresinaro River. To date, these springs have not yet been exploited, as the knowledge about the hydrogeological characteristics of the aquifer and their hydrological behaviour is not fully achieved. This study aims to describe the recharge processes and to define the hydrogeological boundaries of the aquifer. It is based on river and spring discharge monitoring and groundwater balance assessment carried out during the period 2012-2013. Results confirm the effectiveness of the approach, as it allowed the total aliquot of discharge of the springs to be assessed. Moreover, by comparing the observed discharge volume with the one calculated with the groundwater balance, the aquifer has been identified with the arenite slab (mean altitude of 580 m a.s.l.), extended about 5.5 km2 and located 1 km west of the monitored springs.

  11. Compliance Groundwater Monitoring of Nonpoint Sources - Emerging Approaches

    NASA Astrophysics Data System (ADS)

    Harter, T.

    2008-12-01

    Groundwater monitoring networks are typically designed for regulatory compliance of discharges from industrial sites. There, the quality of first encountered (shallow-most) groundwater is of key importance. Network design criteria have been developed for purposes of determining whether an actual or potential, permitted or incidental waste discharge has had or will have a degrading effect on groundwater quality. The fundamental underlying paradigm is that such discharge (if it occurs) will form a distinct contamination plume. Networks that guide (post-contamination) mitigation efforts are designed to capture the shape and dynamics of existing, finite-scale plumes. In general, these networks extend over areas less than one to ten hectare. In recent years, regulatory programs such as the EU Nitrate Directive and the U.S. Clean Water Act have forced regulatory agencies to also control groundwater contamination from non-incidental, recharging, non-point sources, particularly agricultural sources (fertilizer, pesticides, animal waste application, biosolids application). Sources and contamination from these sources can stretch over several tens, hundreds, or even thousands of square kilometers with no distinct plumes. A key question in implementing monitoring programs at the local, regional, and national level is, whether groundwater monitoring can be effectively used as a landowner compliance tool, as is currently done at point-source sites. We compare the efficiency of such traditional site-specific compliance networks in nonpoint source regulation with various designs of regional nonpoint source monitoring networks that could be used for compliance monitoring. We discuss advantages and disadvantages of the site vs. regional monitoring approaches with respect to effectively protecting groundwater resources impacted by nonpoint sources: Site-networks provide a tool to enforce compliance by an individual landowner. But the nonpoint source character of the contamination and its typically large spatial extend requires extensive networks at an individual site to accurately and fairly monitor individual compliance. In contrast, regional networks seemingly fail to hold individual landowners accountable. But regional networks can effectively monitor large-scale impacts and water quality trends; and thus inform regulatory programs that enforce management practices tied to nonpoint source pollution. Regional monitoring networks for compliance purposes can face significant challenges in the implementation due to a regulatory and legal landscape that is exclusively structured to address point sources and individual liability, and due to the non-intensive nature of a regional monitoring program (lack of control of hot spots; lack of accountability of individual landowners).

  12. Estimating aquatic hazards posed by prescription pharmaceutical residues from municipal wastewater

    EPA Science Inventory

    Risks posed by pharmaceuticals in the environment are hard to estimate due to limited monitoring capacity and difficulty interpreting monitoring results. In order to partially address these issues, we suggest a method for prioritizing pharmaceuticals for monitoring, and a framewo...

  13. Citizen Hydrology and Compressed-Air Hydropower for Rural Electrification in Haiti

    NASA Astrophysics Data System (ADS)

    Allen, S. M.

    2015-12-01

    At the present time, only one in eight residents of Haiti has access to electricity. Two recent engineering and statistical innovations have the potential for vastly reducing the cost of installation of hydropower in Haiti and the rest of the developing world. The engineering innovation is that wind, solar and fluvial energy have been used to compress air for generation of electricity for only 20 per megawatt-hour, in contrast to the conventional World Bank practice of funding photovoltaic cells for 156 per megawatt-hour. The installation of hydropower requires a record of stream discharge, which is conventionally obtained by installing a gaging station that automatically monitors gage height (height of the water surface above a fixed datum). An empirical rating curve is then used to convert gage height to stream discharge. The multiple field measurements of gage height and discharge over a wide range of discharge values that are required to develop and maintain a rating curve require a manpower of hydrologic technicians that is prohibitive in remote and impoverished areas of the world. The statistical innovation is that machine learning has been applied to the USGS database of nearly four million simultaneous measurements of gage height and discharge to develop a new classification of rivers so that a rating curve can be developed solely from the stream slope, channel geometry, horizontal and vertical distances to the nearest upstream and downstream confluences, and two pairs of discharge - gage height measurements. The objective of this study is to organize local residents to monitor gage height at ten stream sites in the northern peninsula of Haiti over a one-year period in preparation for installation of hydropower at one of the sites. The necessary baseline discharge measurements and channel surveying are being carried out for conversion of gage height to discharge. Results will be reported at the meeting.

  14. Assessing cadmium and vanadium accumulation using diffusive gradient in thin-films (DGT) and phytoplankton in the Churchill River estuary, Manitoba.

    PubMed

    Mangal, V; Zhu, Y; Shi, Y X; Guéguen, C

    2016-11-01

    Diffusive gradient in thin films (DGT) and phytoplankton communities were evaluated for the measurement of Cd and V at environmentally relevant concentrations in laboratory settings and in the Churchill River estuary (Manitoba, Canada) during an annual spring melt. Despite rapid changes in hydrology and water quality, DGT samplers and intracellular Cd and V concentrations were positively correlated (0.79 < r(2) < 0.99), suggesting comparable accumulation trends between both DGT-labile and intracellular monitoring techniques. The largest accumulated concentrations of both Cd and V by DGT and phytoplankton accumulation methods were found later into the river discharge period. In controlled settings, accumulated Cd and V concentrations by the diatom Attheya septentrionalis displayed a strong correlation with metals accumulated by DGTs (r(2) > 0.99). Principal component analysis (PCA) reinforced similarities between both metal monitoring techniques and assessed how changing environmental variables during the river discharge period influenced each monitoring technique. Cd accumulation was influenced by DOC concentrations and protein-like DOM whereas ionic strength (i.e. conductivity) and humic-like DOM influenced V accumulation. The present findings suggest that (1) DGT is a versatile tool for monitoring bioaccumulation of Cd and V in highly dynamic environmental systems and (2) DOC concentration, DOM composition, conductivity, pH, and river discharge influence the bioavailability of Cd and V in estuarine and riverine waters. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Comparison of balance of tritium activity in waste water from nuclear power plants and at selected monitoring sites in the Vltava River, Elbe River and Jihlava (Dyje) River catchments in the Czech Republic.

    PubMed

    Hanslík, Eduard; Marešová, Diana; Juranová, Eva; Sedlářová, Barbora

    2017-12-01

    During the routine operation, nuclear power plants discharge waste water containing a certain amount of radioactivity, whose main component is the artificial radionuclide tritium. The amounts of tritium released into the environment are kept within the legal requirements, which minimize the noxious effects of radioactivity, but the activity concentration is well measurable in surface water of the recipient. This study compares amount of tritium activity in waste water from nuclear power plants and the tritium activity detected at selected relevant sites of surface water quality monitoring. The situation is assessed in the catchment of the Vltava and Elbe Rivers, affected by the Temelín Nuclear Power Plant as well as in the Jihlava River catchment (the Danube River catchment respectively), where the waste water of the Dukovany Nuclear Power Plant is discharged. The results show a good agreement of the amount of released tritium stated by the power plant operator and the tritium amount detected in the surface water and highlighted the importance of a robust independent monitoring of tritium discharged from a nuclear power plant which could be carried out by water management authorities. The outputs of independent monitoring allow validating the values reported by a polluter and expand opportunities of using tritium as e.g. tracer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Absence of early epileptiform abnormalities predicts lack of seizures on continuous EEG.

    PubMed

    Shafi, Mouhsin M; Westover, M Brandon; Cole, Andrew J; Kilbride, Ronan D; Hoch, Daniel B; Cash, Sydney S

    2012-10-23

    To determine whether the absence of early epileptiform abnormalities predicts absence of later seizures on continuous EEG monitoring of hospitalized patients. We retrospectively reviewed 242 consecutive patients without a prior generalized convulsive seizure or active epilepsy who underwent continuous EEG monitoring lasting at least 18 hours for detection of nonconvulsive seizures or evaluation of unexplained altered mental status. The findings on the initial 30-minute screening EEG, subsequent continuous EEG recordings, and baseline clinical data were analyzed. We identified early EEG findings associated with absence of seizures on subsequent continuous EEG. Seizures were detected in 70 (29%) patients. A total of 52 patients had their first seizure in the initial 30 minutes of continuous EEG monitoring. Of the remaining 190 patients, 63 had epileptiform discharges on their initial EEG, 24 had triphasic waves, while 103 had no epileptiform abnormalities. Seizures were later detected in 22% (n = 14) of studies with epileptiform discharges on their initial EEG, vs 3% (n = 3) of the studies without epileptiform abnormalities on initial EEG (p < 0.001). In the 3 patients without epileptiform abnormalities on initial EEG but with subsequent seizures, the first epileptiform discharge or electrographic seizure occurred within the first 4 hours of recording. In patients without epileptiform abnormalities during the first 4 hours of recording, no seizures were subsequently detected. Therefore, EEG features early in the recording may indicate a low risk for seizures, and help determine whether extended monitoring is necessary.

  17. Absence of early epileptiform abnormalities predicts lack of seizures on continuous EEG

    PubMed Central

    Westover, M. Brandon; Cole, Andrew J.; Kilbride, Ronan D.; Hoch, Daniel B.; Cash, Sydney S.

    2012-01-01

    Objective: To determine whether the absence of early epileptiform abnormalities predicts absence of later seizures on continuous EEG monitoring of hospitalized patients. Methods: We retrospectively reviewed 242 consecutive patients without a prior generalized convulsive seizure or active epilepsy who underwent continuous EEG monitoring lasting at least 18 hours for detection of nonconvulsive seizures or evaluation of unexplained altered mental status. The findings on the initial 30-minute screening EEG, subsequent continuous EEG recordings, and baseline clinical data were analyzed. We identified early EEG findings associated with absence of seizures on subsequent continuous EEG. Results: Seizures were detected in 70 (29%) patients. A total of 52 patients had their first seizure in the initial 30 minutes of continuous EEG monitoring. Of the remaining 190 patients, 63 had epileptiform discharges on their initial EEG, 24 had triphasic waves, while 103 had no epileptiform abnormalities. Seizures were later detected in 22% (n = 14) of studies with epileptiform discharges on their initial EEG, vs 3% (n = 3) of the studies without epileptiform abnormalities on initial EEG (p < 0.001). In the 3 patients without epileptiform abnormalities on initial EEG but with subsequent seizures, the first epileptiform discharge or electrographic seizure occurred within the first 4 hours of recording. Conclusions: In patients without epileptiform abnormalities during the first 4 hours of recording, no seizures were subsequently detected. Therefore, EEG features early in the recording may indicate a low risk for seizures, and help determine whether extended monitoring is necessary. PMID:23054233

  18. A preliminary index of biotic integrity for monitoring the condition of the Rio Paraiba do Sul, southeast Brazil.

    PubMed

    Araujo, Francisco Gerson; Fichberg, Ilana; Pinto, Benjamin Carvalho Teixeira; Peixoto, Magna Galvao

    2003-10-01

    The biodiversity of many Brazilian rivers is seriously threatened by industrial and municipal pollution, and Rio Paraiba do Sul, located between two major industrial centers is one example of this situation. A survey of the fish assemblage was conducted from October 1998 to September 1999 and the data were used to develop an index of biotic integrity (IBI). We sampled three zones in bracketing a large urban-industrial complex to evaluate water quality changes and the usefulness of the IBI as a monitoring tool. Water quality was classified as poor upstream of the effluent discharges, very poor near the discharges, and poor-fair downstream of the discharges, with this latter situation revealing the current biological capacity of the river. Physical and chemical habitat characteristics were also measured at each site to construct an independent environmental index to validate the IBI. The habitat and IBI indices were highly correlated, suggesting this IBI would be applicable to other large rivers in southeast Brazil.

  19. Corona discharge ion mobility spectrometry with orthogonal acceleration time of flight mass spectrometry for monitoring of volatile organic compounds.

    PubMed

    Sabo, Martin; Matejčík, Štefan

    2012-06-19

    We demonstrate the application of corona discharge ion mobility spectrometry with orthogonal acceleration time of flight mass spectrometry (CD IMS-oaTOF) for volatile organic compounds (VOCs) monitoring. Two-dimensional (2D) IMS-oaTOF spectra of VOCs were recorded in nearly real time. The corona discharge atmospheric pressure chemical ionization (APCI) source was operated in positive mode in nitrogen and air. The CD ion source generates in air H(3)O(+)(H(2)O)(n) and NO(+). The NO(+) offers additional possibility for selective ionization and for an increase of the sensitivity of monoaromatic compounds. In addition to H(3)O(+)(H(2)O)(n) and NO(+), we have carried out ionization of VOCs using acetone as dopant gas ((CH(3))(2)COH(+)). Sixteen model VOCs (tetrahydrofuran, butanol, n-propanol, iso-propano, acetone, methanol, ethanol, toluene, benzene, amomnia, dioxan, triethylamine, acetonitrile, formaldehyde, m-xylene, 2,2,2-trifluoroethylamine) were tested using these ionization techniques.

  20. Two cases of childhood narcolepsy mimicking epileptic seizures in video-EEG/EMG.

    PubMed

    Yanagishita, Tomoe; Ito, Susumu; Ohtani, Yui; Eto, Kaoru; Kanbayashi, Takashi; Oguni, Hirokazu; Nagata, Satoru

    2018-06-06

    Narcolepsy is characterized by excessive sleepiness, hypnagogic hallucinations, and sleep paralysis, and can occur with or without cataplexy. Here, we report two children with narcolepsy presenting with cataplexy mimicking epileptic seizures as determined by long-term video-electroencephalography (EEG) and electromyography (EMG) monitoring. Case 1 was a 15-year-old girl presenting with recurrent episodes of "convulsions" and loss of consciousness, who was referred to our hospital with a diagnosis of epilepsy showing "convulsions" and "complex partial seizures". The long-term video-polygraph showed a clonic attack lasting for 15 s, which corresponded to 1-2 Hz with interruption of mentalis EMG discharges lasting for 70-300 ms without any EEG changes. Narcolepsy was suspected due to the attack induced by hearty laughs and the presence of sleep attacks, and confirmed by low orexin levels in cerebrospinal fluid (CSF). Case 2 was an 11-year-old girl presenting with recurrent episodes of myoclonic attacks simultaneously with dropping objects immediately after hearty laughs, in addition to sleep attacks, hypnagogic hallucinations, and sleep paralysis. The long-term video-polygraph showed a subtle attack, characterized by dropping chopsticks from her hand, which corresponded to an interruption of ongoing deltoid EMG discharges lasting 140 ms without any EEG changes. A diagnosis of narcolepsy was confirmed by the low orexin levels in CSF. These cases demonstrate that children with narcolepsy may have attacks of cataplexy that resemble clonic or myoclonic seizures. Copyright © 2018 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  1. Linking drugs of abuse in wastewater to contamination of surface and drinking water.

    PubMed

    Rodayan, Angela; Afana, Shadi; Segura, Pedro A; Sultana, Tamanna; Metcalfe, Chris D; Yargeau, Viviane

    2016-04-01

    The concentrations of 17 drugs of abuse, including cocaine, several amphetamines, opioid drugs, and 2 metabolites--benzoylecgonine, a metabolite of cocaine, and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrolidine, a metabolite of methadone--were investigated in an urban watershed that is heavily impacted by discharges of municipal wastewater. The artificial sweetener sucralose was also monitored as a persistent tracer of contamination from municipal wastewater. Monitoring was conducted in a municipal wastewater treatment plant (WWTP) and at sites upstream and downstream of the WWTP discharge, as well as in a drinking water treatment plant (DWTP) located 19 km downstream of the WWTP discharge that withdraws raw water from the river. Drug concentrations were monitored with polar organic chemical integrative samplers deployed for 2 wk in the river and in the WWTP and DWTP. Several of the investigated compounds exhibited a decrease in concentration with distance downstream from the wastewater discharge into the river, but there was little attenuation of sucralose, cocaine, benzoylecgonine, morphine, acetylmorphine, acetylcodeine, and oxycodone. Heroin and methadone were not detected at any sample locations. Amphetamine, methamphetamine, 3,4-methylenedioxy-methamphetamine, and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrolidine were not detected in the samples collected at the drinking water intake. Many of the drugs of abuse were not removed effectively in the DWTP, including cocaine, benzoylecgonine, methylenedioxyamphetamine, ephedrine, and several prescription opioids, most probably because the DWTP was operating at or above its rated treatment capacity. These data indicate that there can be transport of drugs of abuse from wastewater sources into drinking water in urban watersheds. © 2015 SETAC.

  2. Characterization and statistical modeling of bacterial (Escherichia coli) outflows from watersheds that discharge into Southern Lake Michigan

    USGS Publications Warehouse

    Olyphant, G.A.; Thomas, Joan; Whitman, R.L.; Harper, D.

    2003-01-01

    Two watersheds in northwestern Indiana were selected for detailed monitoring of bacterially contaminated discharges (Escherichia coli) into Lake Michigan. A large watershed that drains an urbanized area with treatment plants that release raw sewage during storms discharges into Lake Michigan at the outlet of Burns Ditch. A small watershed drains part of the Great Marsh, a wetland complex that has been disrupted by ditching and limited residential development, at the outlet of Derby Ditch. Monitoring at the outlet of Burns Ditch in 1999 and 2000 indicated that E. coli concentrations vary over two orders of magnitude during storms. During one storm, sewage overflows caused concentrations to increase to more than 10,000 cfu/100 mL for several hours. Monitoring at Derby Ditch from 1997 to 2000 also indicated that E. coli concentrations increase during storms with the highest concentrations generally occurring during rising streamflow. Multiple regression analysis indicated that 60% of the variability in measured outflows of E. coli from Derby Ditch (n = 88) could be accounted for by a model that utilizes continuously measured rainfall, stream discharge, soil temperature and depth to water table in the Great Marsh. A similar analysis indicated that 90% of the variability in measured E. coli concentrations at the outlet of Burns Ditch (n = 43) during storms could be accounted for by a combination of continuously measured water-quality variables including nitrate and ammonium. These models, which utilize data that can be collected on a real-time basis, could form part of an Early Warning System for predicting beach closures.

  3. Improved understanding of solute concentration-discharge dynamics through state-of-the-art antecedent moisture content (AMC) monitoring and analysis

    NASA Astrophysics Data System (ADS)

    Eludoyin, A. O.; Brazier, R.; Quine, T.; Bol, R.; Orr, R.; Griffith, B.

    2012-04-01

    The relationship between solute/sediment concentration and discharge (c-Q) can be neither understood nor predicted without full understanding of the antecedent moisture content (AMC). Many preceding studies have ignored this variable in part because of the problems associated with accurate and full documentation of AMC. This study presents new insights into the control of AMC on c-Q made possible through work on the uniquely well-instrumented 'NorthWyke Farm Platform' which was commissioned in April 2011 as a UK national capability for collaborative research, training and knowledge exchange in agro-environmental sciences for agricultural productivity and ecosystem responses to different management practices. The Farm Platform was designed into 15 hydrological units based on a predicted 50-year flood event, each with H-flume at catchment outlet. 9.2 km of French drains were installed at 800mm soil depth with perforated plastic drainage pipe installed to collect surface and near surface flow from the catchments. Each flume receives flow from 2 branches of each French drain system and discharges via concrete piping and a sampling pit. Where required the catchment is protected from groundwater seepage and surface runoff ingress from adjacent catchment with open ditches and sealed pipes. Discharge is measured at each flume with an ISCO bubbler flowmeter, and concentrations of Total Organic Carbon (TOC), Ammonium (NH4-N), Nitrate (NO3-N), Dissolved Oxygen (DO), total Phosphorus, chloride, pH and turbidity are monitored at 15 minutes intervals. In addition, rainfall, soil temperature and soil moisture are monitored at the same timestep. This study analyses discharge and soil moisture data alongside TOC, NO3-N and PO4-P at 15 min intervals in rain events between November 28 and December 13, 2011. Soil moisture exhibited moderately strong relationships with TOC and NO3 (r≥ -0.38; p≤0.05), but a weak one with PO4. Discharge, on the other hand, exhibited a weak (r ≤0.08; p>0.05) with all the ions. These results suggest that the behaviour of these ions is not explained by discharge alone. Analysis is in progress to determine the influence of soil moisture on hysteresis loops of these ions, as well as their contribution, with other end members to runoff in this study.

  4. Human-centered design for neonatal apnea monitoring: application of the UFuRT process to analyze a monitor display layout.

    PubMed

    Brannon, Timothy S

    2008-11-06

    Resolution of apnea of prematurity is a criterion for hospital discharge of the preterm infant. False alarms recorded as true events can prolong hospitalization and increase cost of care. The UFuRT process was used to analyze neonatal apnea monitoring, using a typical monitor display. The goals were to determine 1) the data needed to recognize true events and reject false alarms, and 2) how the display layout could be modified to better support these tasks.

  5. A purity monitor for the KEDR liquid krypton calorimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evtushenko, P. N.; Kotov, K. Yu.; Maslennikov, A. L.

    We present a purity monitor for the KEDR liquid krypton calorimeter. A new method is suggested based on the usage of a short pulse of a gas discharge as a source of ultraviolet radiation for the photoproduction of electrons in a drift cell of the monitor. This paper describes the design of the monitor, the results of experiments with gaseous and liquid krypton, as well as the experience of using the developed device in the process of krypton purification for the KEDR liquid krypton calorimeter.

  6. Closed Cycle Electric Discharge Laser Design Investigation

    DTIC Science & Technology

    1978-03-01

    Report Number Assigned by Contract Monitor: NASA CR- 135408 Comments on Document: Archive, RRI, DEW Descriptors, Keywords: Closed Cycle Electric...Discharge Laser Design Investigation Carbon Dioxide Monoxide Space Airborne Heat Disposal Point Track Power Solar Generator Radiation Pages: 00100...Cataloged Date: Nov 27,1992 Contract Number: NAS 3-20100 Document Type: HC Number of Copies In Library: 000001 Record ID: 25219 Source of Document: DEW

  7. Computational Gene Mapping to Analyze Continuous Automated Real-Time Vital Signs Monitoring Data

    DTIC Science & Technology

    2013-09-23

    Analysis as Most Likely to Provide Useful Information at 12 Hours into Care Regarding Eventual Outcome = GOSE at 3 Months……………………………………………………. 8...6 Weeks Post Discharge) GOSE Using the First 12 Hours of Data...Discharge) GOSE Using the First 12 Hours of Data .......................................................................................... 11

  8. Effect of different transport observations on inverse modeling results: case study of a long-term groundwater tracer test monitored at high resolution

    NASA Astrophysics Data System (ADS)

    Rasa, Ehsan; Foglia, Laura; Mackay, Douglas M.; Scow, Kate M.

    2013-11-01

    Conservative tracer experiments can provide information useful for characterizing various subsurface transport properties. This study examines the effectiveness of three different types of transport observations for sensitivity analysis and parameter estimation of a three-dimensional site-specific groundwater flow and transport model: conservative tracer breakthrough curves (BTCs), first temporal moments of BTCs ( m 1), and tracer cumulative mass discharge ( M d) through control planes combined with hydraulic head observations ( h). High-resolution data obtained from a 410-day controlled field experiment at Vandenberg Air Force Base, California (USA), have been used. In this experiment, bromide was injected to create two adjacent plumes monitored at six different transects (perpendicular to groundwater flow) with a total of 162 monitoring wells. A total of 133 different observations of transient hydraulic head, 1,158 of BTC concentration, 23 of first moment, and 36 of mass discharge were used for sensitivity analysis and parameter estimation of nine flow and transport parameters. The importance of each group of transport observations in estimating these parameters was evaluated using sensitivity analysis, and five out of nine parameters were calibrated against these data. Results showed the advantages of using temporal moment of conservative tracer BTCs and mass discharge as observations for inverse modeling.

  9. Influence of local calibration on the quality of online wet weather discharge monitoring: feedback from five international case studies.

    PubMed

    Caradot, Nicolas; Sonnenberg, Hauke; Rouault, Pascale; Gruber, Günter; Hofer, Thomas; Torres, Andres; Pesci, Maria; Bertrand-Krajewski, Jean-Luc

    2015-01-01

    This paper reports about experiences gathered from five online monitoring campaigns in the sewer systems of Berlin (Germany), Graz (Austria), Lyon (France) and Bogota (Colombia) using ultraviolet-visible (UV-VIS) spectrometers and turbidimeters. Online probes are useful for the measurement of highly dynamic processes, e.g. combined sewer overflows (CSO), storm events, and river impacts. The influence of local calibration on the quality of online chemical oxygen demand (COD) measurements of wet weather discharges has been assessed. Results underline the need to establish local calibration functions for both UV-VIS spectrometers and turbidimeters. It is suggested that practitioners calibrate locally their probes using at least 15-20 samples. However, these samples should be collected over several events and cover most of the natural variability of the measured concentration. For this reason, the use of automatic peristaltic samplers in parallel to online monitoring is recommended with short representative sampling campaigns during wet weather discharges. Using reliable calibration functions, COD loads of CSO and storm events can be estimated with a relative uncertainty of approximately 20%. If no local calibration is established, concentrations and loads are estimated with a high error rate, questioning the reliability and meaning of the online measurement. Similar results have been obtained for total suspended solids measurements.

  10. Nested monitoring approaches to delineate groundwater trichloroethene discharge to a UK lowland stream at multiple spatial scales.

    PubMed

    Weatherill, John; Krause, Stefan; Voyce, Kevin; Drijfhout, Falko; Levy, Amir; Cassidy, Nigel

    2014-03-01

    Integrated approaches for the identification of pollutant linkages between aquifers and streams are of crucial importance for evaluating the environmental risks posed by industrial contaminants like trichloroethene (TCE). This study presents a systematic, multi-scale approach to characterising groundwater TCE discharge to a 'gaining' UK lowland stream receiving baseflow from a major Permo-Triassic sandstone aquifer. Beginning with a limited number of initial monitoring points, we aim to provide a 'first pass' mechanistic understanding of the plume's fate at the aquifer/stream interface using a novel combination of streambed diffusion samplers, riparian monitoring wells and drive-point mini-piezometers in a spatially nested sampling configuration. Our results indicate the potential discharge zone of the plume to extend along a stream reach of 120 m in length, delineated by a network of 60 in-situ diffusion samplers. Within this section, a 40 m long sub-reach of higher concentration (>10 μg L(-1)) was identified; centred on a meander bend in the floodplain. 25 multi-level mini-piezometers installed to target this down-scaled reach revealed even higher TCE concentrations (20-40 μg L(-1)), significantly above alluvial groundwater samples (<6 μg L(-1)) from 15 riparian monitoring wells. Significant lateral and vertical spatial heterogeneity in TCE concentrations within the top 1m of the streambed was observed with the decimetre-scale vertical resolution provided by multi-level mini-piezometers. It appears that the distribution of fine-grained material in the Holocene deposits of the riparian floodplain and below the channel is exerting significant local-scale geological controls on the location and magnitude of the TCE discharge. Large-scale in-situ biodegradation of the plume was not evident during the monitoring campaigns. However, detections of cis-1,2-dichloroethene and vinyl chloride in discrete sections of the sediment profile indicate that shallow (e.g., <20 cm) TCE transformation may be significant at a local scale in the streambed deposits. Our findings highlight the need for efficient multi-scale monitoring strategies in geologically heterogeneous lowland stream/aquifer systems in order to more adequately quantify the risk to surface water ecological receptors posed by point-source groundwater contaminants like TCE. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. New insights into hydrochemical processes in lowland river systems gained from in situ, high-resolution monitoring

    NASA Astrophysics Data System (ADS)

    Wade, Andrew; Palmer-Felgate, Elizabeth; Halliday, Sarah; Skeffington, Richard; Loewenthal, Matthew; Jarvie, Helen; Bowes, Michael; Greenway, Gillian; Haswell, Stephen; Bell, Ian; Joly, Etienne; Fallatah, Ahmed; Neal, Colin; Williams, Richard; Gozzard, Emma; Newman, Jonathan

    2013-04-01

    This work focuses on the insights obtained from in situ, high-resolution hydrochemical monitoring in three lowland UK catchments experiencing different levels of nutrient enrichment. Between November 2009 and February 2012, the upper River Kennet, the River Enborne and The Cut, all located within the Thames basin, southeast England, were instrumented with in situ analytical equipment to make hourly measurements of a range of hydrochemical determinands. The upper River Kennet is a rural catchment with limited effluent inputs above the selected monitoring point. The River Enborne is a rural catchment, impacted by agricultural runoff, and septic tank and sewage treatment works (STWs) discharges. The Cut is a highly urbanised system significantly affected by STW discharges. On the upper River Kennet and the River Enborne hourly measurements of Total Reactive Phosphorus (TRP) were made using a Systea Micromac C. In addition on the River Enborne, a Hach Lange Nitratax was used to measure nitrate (NO3). On The Cut both Total P and TRP were measured using a Hach Lange Phosphax Sigma. At all stations nutrient monitoring was supplemented with hourly pH, chlorophyll, dissolved oxygen, conductivity, turbidity and water temperature using YSI 6600 Multi-parameter sondes. Instream hydrochemical dynamics were investigated using non-stationary time-series analysis techniques. The results reveal complex nutrient dynamics, with diurnal patterns which exhibit seasonal changes in phase and amplitude, and are influenced by flow conditions, shading and nutrient sources. On the River Enborne a marked diurnal cycle was present within the streamwater NO3 time-series. The cycle was strongest in the spring before riparian shading developed. At times of low flow a two peak diurnal cycle was also evident in the streamwater NO3 time-series. The reduction in diurnal NO3 processing after the development of riparian shading was also accompanied by a marked drop in dissolved oxygen at this time. The presence of a two peak diurnal cycle is indicative of the dominance of STW discharges to the system, as STW discharges exhibit a marked two peak diurnal cycle associated with peak water usage. This two peak diurnal cycling can also been seen in the River Enborne TRP data. The dominance of effluent discharges was also evident in the River Enborne seasonal NO3 and TRP dynamics. Both determinands displayed summer time peaks caused by the reduced dilution capacity of the system and increased water residence time during the low flow summer months. The TP and TRP dynamics on The Cut were highly complex with significant diurnal fluctuations. Although, a two peak diurnal signal was evident within the TRP time-series it was difficult to characterise due to the complexity of the dynamics observed. Monitoring on the upper River Kennet highlighted the challenges associated with undertaking in situ analytical monitoring without mains electricity. Resampling of the data at lower sampling frequencies demonstrated that within the point-source dominated catchments, daily monitoring was sufficient for accurate load estimation.

  12. Monitoring bedload entrainment and transport in snowmelt-dominated forest streams of the Columbia Mountains, Canada

    NASA Astrophysics Data System (ADS)

    Green, Kim; Brardinoni, Francesco; Alila, Younes

    2014-05-01

    We monitor bedload transport and water discharge at six stations in two forested headwater streams of the Columbia Mountains, Canada. The monitoring network of sediment traps is designed to examine the effects of channel bed texture, and the influence of alluvial (i.e., step pools, and riffle pools) and semi-alluvial morphologies (i.e., boulder cascades and forced step pools) on bedload entrainment and transport. Results suggest that patterns of bedload entrainment are influenced by flow resistance while the value of the critical dimensionless shear stress for mobilization of the surface D50 varies due to channel gradient, grain sheltering effects and, to a less extent, flow resistance. Regardless of channel morphology we observe: (i) equal-threshold entrainment for all mobile grains in channels with high grain and/or form resistance; and (ii) initial equal-threshold entrainment of calibers ≤ 22mm, and subsequent size-selective entrainment of coarser material in channels with low form resistance (e.g. riffle pool). Scaled fractional analysis reveals that in reaches with high flow resistance most bedload transport occurs in partial mobility fashion relative to the available bed material and that only material finer than 16mm attains full mobility during over-bank flows. Equal mobility transport for a wider range of grain sizes is achieved in reaches with reduced flow resistance. Evaluation of bedload rating curves across sites identifies that grain effects predominate with respect to bedload flux whereas morphological effects (i.e. form resistance) play a secondary role. Application of selected empirical formulae developed in steep alpine channels present variable success in predicting transport rates in the study reaches.

  13. Estimating river discharge uncertainty by applying the Rating Curve Model

    NASA Astrophysics Data System (ADS)

    Barbetta, S.; Melone, F.; Franchini, M.; Moramarco, T.

    2012-04-01

    The knowledge of the flow discharge at a river site is necessary for planning and management of water resources as well as for monitoring and real-time forecasting purposes when significant flood events occur. In the hydrological practice, the operational discharge measurement in medium and large rivers is mostly based on indirect approaches by converting the observed stage into discharge values using steady-flow rating curves. However, the stage-discharge relationship can be unknown for hydrometric sections where flow velocity measurements, particularly during high floods, are not available. To overcome this issue, a simplified approach named Rating Curve Model (RCM) and proposed by Moramarco et al. (Moramarco, T., Barbetta, S., F. Melone, F. & Singh, V.P., Relating local stage and remote discharge with significant lateral inflow, J. Hydrol. Engng ASCE, 10[1], 58?69, 2005) can be conveniently used. RCM turned out able to assess, with a high level of accuracy, the discharge hydrograph at a river site where only the stage is monitored while the flow is recorded at a different section along the river, even when significant lateral flows occur. The simple structure of the model is depending on three parameters of which two can be considered characteristic of the river reach and one of the wave travel time of floods. Considering that RCM well lends itself to predict the stage-discharge relationship at a river site wherein only stages are recorded, an uncertainty analysis on river discharge estimate is of interest for the hydrological practice definitely. To this aim, the uncertainty characterizing the RCM outcomes is addressed in this work by considering two different procedures based on the Monte Carlo approach and the Generalized Likelihood Uncertainty Estimation (GLUE) method, respectively. The statistical distribution of parameters is found and a random re-sampling of parameters is done for assessing the 90% confidence interval (CI) of discharge estimates. In particular, for the latter approach the Nash-Sutcliffe coefficient is used as likelihood measure. Two equipped river reaches of the Upper-Middle Tiber River basin, central Italy, are investigated as case studies. The results provided by the selected methodologies are discussed and compared showing that all the computed CIs are satisfied in term of percentage of included observed discharges with similar percentages characterizing the bands assessed by both Monte Carlo approach and GLUE procedure.

  14. Spatial and temporal dynamics of nitrate fluxes in a mesoscale catchment

    NASA Astrophysics Data System (ADS)

    Muller, C.; Musolff, A.; Strachauer, U.; Brauns, M.; Tarasova, L.; Merz, R.; Knoeller, K.

    2017-12-01

    Spatially and temporally variable and often superimposing processes like mobilization and turnover of N-species strongly affect nitrate fluxes at catchment outlets. It remains thus challenging to determine dominant nitrate sources to derive an effective river management. Here, we combine data sets from two spatially highly resolved key-date monitoring campaigns of nitrate fluxes along a mesoscale catchment in Germany with four years of monitoring data from two representative sites within the catchment. The study area is characterized by a strong land use gradient from pristine headwaters to lowland sub-catchments with intense agricultural land use and wastewater sources. Flow conditions were assessed by a hydrograph separation showing the clear dominance of base flow during both investigations. However, the absolute amounts of discharge differed significantly from each other (outlet: 1.42 m³ s-1 versus 0.43 m³ s-1). Nitrate concentration and flux in the headwater was found to be low. In contrast, nitrate loads further downstream originate from anthropogenic sources such as effluents from wastewater treatment plants (WWTP) and agricultural land use. The agricultural contribution did not vary in terms of nitrate concentration and isotopic signature between the years but in terms of flux. The contrasting amounts of discharge between the years led to a strongly increased relative wastewater contribution with decreasing discharge. This was mainly manifested in elevated δ18O-NO3- values downstream from the wastewater discharge. The four-year monitoring at two sides clearly indicates the chemostatic character of the agricultural N-source and its distinct, yet stable isotopic fingerprint. Denitrification was found to play no dominant role only for controlling nitrate loads in the river. The spatially highly resolved monitoring approach helped to accurately define hot spots of nitrate inputs into the stream while the long-term information allowed a classification of the results with respect to the seasonal N-dynamics in the catchment.

  15. Geothermal solute flux monitoring and the source and fate of solutes in the Snake River, Yellowstone National Park, WY

    USGS Publications Warehouse

    McCleskey, R. Blaine; Lowenstern, Jacob B.; Schaper, Jonas; Nordstrom, D. Kirk; Heasler, Henry P.; Mahony, Dan

    2016-01-01

    The combined geothermal discharge from over 10,000 features in Yellowstone National Park (YNP) can be can be estimated from the Cl flux in the Madison, Yellowstone, Falls, and Snake Rivers. Over the last 30 years, the Cl flux in YNP Rivers has been calculated using discharge measurements and Cl concentrations determined in discrete water samples and it has been determined that approximately 12% of the Cl flux exiting YNP is from the Snake River. The relationship between electrical conductivity and concentrations of Cl and other geothermal solutes was quantified at a monitoring site located downstream from the thermal inputs in the Snake River. Beginning in 2012, continuous (15 min) electrical conductivity measurements have been made at the monitoring site. Combining continuous electrical conductivity and discharge data, the Cl and other geothermal solute fluxes were determined. The 2013–2015 Cl fluxes (5.3–5.8 kt/yr) determined using electrical conductivity are comparable to historical data. In addition, synoptic water samples and discharge data were obtained from sites along the Snake River under low-flow conditions of September 2014. The synoptic water study extended 17 km upstream from the monitoring site. Surface inflows were sampled to identify sources and to quantify solute loading. The Lewis River was the primary source of Cl, Na, K, Cl, SiO2, Rb, and As loads (50–80%) in the Snake River. The largest source of SO4 was from the upper Snake River (50%). Most of the Ca and Mg (50–55%) originate from the Snake Hot Springs. Chloride, Ca, Mg, Na, K, SiO2, F, HCO3, SO4, B, Li, Rb, and As behave conservatively in the Snake River, and therefore correlate well with conductivity (R2 ≥ 0.97).

  16. The effects of combined sewer overflow events on riverine sources of drinking water.

    PubMed

    Madoux-Humery, Anne-Sophie; Dorner, Sarah; Sauvé, Sébastien; Aboulfadl, Khadija; Galarneau, Martine; Servais, Pierre; Prévost, Michèle

    2016-04-01

    This study was set out to investigate the impacts of Combined Sewer Overflows (CSOs) on the microbiological water quality of a river used as a source of drinking water treatment plants. Escherichia coli concentrations were monitored at various stations of a river segment located in the Greater Montreal Area including two Drinking Water Intakes (DWIs) in different weather conditions (dry weather and wet weather (precipitation and snowmelt period)). Long-term monitoring data (2002-2011) at DWIs revealed good microbiological water quality with E. coli median concentrations of 20 and 30 CFU/100 mL for DWI-1 and DWI-2 respectively. However, E. coli concentration peaks reached up to 510 and 1000 CFU/100 mL for both DWIs respectively. Statistical Process Control (SPC) analysis allowed the identification of E. coli concentration peaks in almost a decade of routine monitoring data at DWIs. Almost 80% of these concentrations were linked to CSO discharges caused by precipitation exceeding 10 mm or spring snowmelt. Dry weather monitoring confirmed good microbiological water quality. Wet weather monitoring showed an increase of approximately 1.5 log of E. coli concentrations at DWIs. Cumulative impacts of CSO discharges were quantified at the river center with an increase of approximately 0.5 log of E. coli concentrations. Caffeine (CAF) was tested as a potential chemical indicator of CSO discharges in the river and CAF concentrations fell within the range of previous measurements performed for surface waters in the same area (∼20 ng/L). However, no significant differences were observed between CAF concentrations in dry and wet weather, as the dilution potential of the river was too high. CSO event based monitoring demonstrated that current bi-monthly or weekly compliance monitoring at DWIs underestimate E. coli concentrations entering DWIs and thus, should not be used to quantify the risk at DWIs. High frequency event-based monitoring is a desirable approach to establish the importance and duration of E. coli peak concentrations entering DWIs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Culvert analysis program for indirect measurement of discharge

    USGS Publications Warehouse

    Fulford, Janice M.; ,

    1993-01-01

    A program based on the U.S. Geological Survey (USGS) methods for indirectly computing peak discharges through culverts allows users to employ input data formats used by the water surface profile program (WSPRO). The program can be used to compute discharge rating surfaces or curves that describe the behavior of flow through a particular culvert or to compute discharges from measurements of upstream of the gradually varied flow equations and has been adapted slightly to provide solutions that minimize the need for the user to determine between different flow regimes. The program source is written in Fortran 77 and has been run on mini-computers and personal computers. The program does not use or require graphics capability, a color monitor, or a mouse.

  18. Trend analyses of sediment data for the DEC project

    USGS Publications Warehouse

    Rebich, Richard Allen

    1995-01-01

    Daily stream discharge, suspended-sediment concentration, and suspended-sediment discharge data were collected at eight sites in six watersheds of the Demonstration Erosion Control project in the Yazoo River Basin in north-central Mississippi during the period July 1985 through September 1991. The project is part of an ongoing interagency program of planning, design, construction, monitoring, and evaluation to alleviate flooding, erosion, sedimentation, and water-quality problems for watersheds located in the bluff hills upstream of the Mississippi River alluvial plain. This paper presents preliminary results of trend analyses for stream discharge and sediment data for the eight project sites. More than 550 stream discharge measurements and 20,000 suspended-sediment samples have been collected at the eight sites since 1985.

  19. Preliminary measurements of neutrons from the D-D reaction in the COMPASS tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dankowski, J., E-mail: jan.dankowski@ifj.edu.pl; Kurowski, A.; Twarog, D.

    Recent results of measured fast neutrons created in the D-D reaction on the COMPASS tokamak during ohmic discharges are presented in this paper. Two different type detectors were used during experiment. He-3 detectors and bubble detectors as a support. The measurements are an introduction for neutron diagnostic on tokamak COMPASS and monitoring neutrons during discharges with Neutral Beam Injection (NBI). The He-3 counters and bubble detectors were located in two positions near tokamak vacuum chamber at a distance less than 40 cm to the centre of plasma. The neutrons flux was observed in ohmic discharges. However, analysis of our resultsmore » does not indicate any clear source of neutrons production during ohmic discharges.« less

  20. 77 FR 45968 - National Oil and Hazardous Substances Pollution Contingency Plan; National Priorities List...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-02

    ... (soil and groundwater) of the properties proposed for deletion. DATES: This direct final partial... site media, including soil and groundwater for the following properties: Properties owned by the Town... streams were finally directed to the WWTP. As a result of these discharges, overburden soil and bedrock...

Top