Sample records for partial thickness rotator

  1. Arthroscopic repair of partial-thickness and small full-thickness rotator cuff tears: tendon quality as a prognostic factor for repair integrity.

    PubMed

    Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong

    2015-03-01

    The healing failure rate is high for partial-thickness or small full-thickness rotator cuff tears. To retrospectively evaluate and compare outcomes after arthroscopic repair of high-grade partial-thickness and small full-thickness rotator cuff tears and factors affecting rotator cuff healing. Cohort study; Level of evidence, 3. Included in the study were 55 consecutive patients (mean age, 57.9 ± 7.2 years) who underwent arthroscopic repair for high-grade partial-thickness (n = 34) and small full-thickness (n = 21) rotator cuff tears. The study patients also underwent magnetic resonance imaging (MRI) preoperatively and computed tomography arthrography (CTA) at least 6 months postoperatively, and their functional outcomes were evaluated preoperatively and at the last follow-up (>24 months). All partial-thickness tears were repaired after being converted to full-thickness tears; thus, the repair process was almost the same as for small full-thickness tears. The tendinosis of the torn tendon was graded from the MRI images using a 4-point scale, and the reliabilities were assessed. The outcomes between high-grade partial-thickness tears that were converted to small full-thickness tears and initially small full-thickness tears were compared, and factors affecting outcomes were evaluated. The inter- and intraobserver reliabilities of the tendinosis grade were good (intraclass correlation coefficient, 0.706 and 0.777, respectively). Failure to heal as determined by CTA was observed in 12 patients with a high-grade partial-thickness tear (35.3%; complete failure in 4 and partial failure in 8) and in 3 patients with a small full-thickness tear (14.3%; complete failure in 1 and partial failure in 2). The patients with high-grade partial-thickness rotator cuff tears showed a higher tendinosis grade than did those with small full-thickness tears (P = .014), and the severity of the tendinosis was related to the failure to heal (P = .037). Tears with a higher tendinosis grade showed a 7.64-times higher failure rate (95% CI, 1.43-36.04) than did those with a lower tendinosis grade (P = .013). All functional outcome scores improved after surgery (all P < .001); however, there was no difference between groups. The high-grade partial-thickness rotator cuff tears showed more severe tendinosis compared with the small full-thickness tears in this study. Contrary to previous impressions that tear size or fatty infiltration is the factor that most influences healing, tendinosis severity assessed by preoperative MRI was the only factor associated with failure to heal, given the numbers available for analysis, in patients with partial-thickness and small full-thickness rotator cuff tears. Surgeons should pay more attention to tendon quality during repair surgery or rehabilitation in smaller rotator cuff tears, especially in high-grade partial-thickness tears with severe tendinosis. © 2014 The Author(s).

  2. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    PubMed

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.

  3. Partial Thickness Rotator Cuff Tears: Current Concepts

    PubMed Central

    Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.

    2015-01-01

    Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251

  4. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    PubMed

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P < 0.001). Logistic regression revealed that having a full-thickness tear was the most reliable risk factor for tear progression (P < 0.001). This study found that 28/34 (82.4%) of symptomatic full-thickness rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be monitored more carefully for progression than partial-thickness tears. IV.

  5. Transtendon, Double-Row, Transosseous-Equivalent Arthroscopic Repair of Partial-Thickness, Articular-Surface Rotator Cuff Tears

    PubMed Central

    Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.

    2014-01-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness. PMID:25473606

  6. Transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears.

    PubMed

    Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D

    2014-10-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.

  7. Biomechanical analysis of articular-sided partial-thickness rotator cuff tear and repair.

    PubMed

    Mihata, Teruhisa; McGarry, Michelle H; Ishihara, Yoko; Bui, Christopher N H; Alavekios, Damon; Neo, Masashi; Lee, Thay Q

    2015-02-01

    Articular-sided partial-thickness rotator cuff tears are common injuries in throwing athletes. The superior shoulder capsule beneath the supraspinatus and infraspinatus tendons works as a stabilizer of the glenohumeral joint. To assess the effect of articular-sided partial-thickness rotator cuff tear and repair on shoulder biomechanics. The hypothesis was that shoulder laxity might be changed because of superior capsular plication in transtendon repair of articular-sided partial-thickness rotator cuff tears. Controlled laboratory study. Nine fresh-frozen cadaveric shoulders were tested by using a custom shoulder-testing system at the simulated late-cocking phase and acceleration phase of throwing motion. Maximum glenohumeral external rotation angle, anterior translation, position of the humeral head apex with respect to the glenoid, internal impingement area, and glenohumeral and subacromial contact pressures were measured. Each specimen underwent 3 stages of testing: stage 1, with the intact shoulder; stage 2, after creation of articular-sided partial-thickness tears of the supraspinatus and infraspinatus tendons; and stage 3, after transtendon repair of the torn tendons by using 2 suture anchors. Articular-sided partial-thickness tears did not significantly change any of the shoulder biomechanical measurements. In the simulated late-cocking phase, transtendon rotator cuff repair resulted in decreased maximum external rotation angle by 4.2° (P = .03), posterior shift of the humeral head (1.1-mm shift; P = .02), decreased glenohumeral contact pressure by 1.7 MPa (56%; P = .004), and decreased internal impingement area by 26.4 mm(2) (65%; P < .001) compared with values in the torn shoulder. In the acceleration phase, the humeral head shifted inferiorly (1.2-mm shift; P = .03 vs torn shoulder), and glenohumeral anterior translation (1.5-mm decrease; P = .03 vs torn shoulder) and subacromial contact pressure (32% decrease; P = .004 vs intact shoulder) decreased significantly after transtendon repair. Transtendon repair of articular-sided partial-thickness supraspinatus and infraspinatus tears decreased glenohumeral and subacromial contact pressures at time zero; these changes might lead to reduced secondary subacromial and internal impingements and consequently progression to full-thickness rotator cuff tear. However, repair of the tendons decreased anterior translation and external rotation and changed the positional relationship between the humeral head and the glenoid. Careful attention should be paid to shoulder laxity and range of motion when transtendon repair is chosen to treat articular-sided partial-thickness rotator cuff tears, specifically in throwing athletes. © 2014 The Author(s).

  8. Delaminated rotator cuff tear: extension of delamination and cuff integrity after arthroscopic rotator cuff repair.

    PubMed

    Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John

    2015-05-01

    The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital.

    PubMed

    Zbojniewicz, Andrew M; Maeder, Matthew E; Emery, Kathleen H; Salisbury, Shelia R

    2014-06-01

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between rotator cuff tears and physeal patency (P > 0.05). Most patients were athletes (76%). Five tears were confirmed at surgery. Poor clinical follow-up limited evaluation of patient outcomes. Rotator cuff tears can be identified during MRI examination of symptomatic child and adolescent shoulders and often consist of tear patterns associated with repetitive microtrauma in overhead athletic activities or with single traumatic events. Rotator cuff tears are seen throughout the range of skeletal maturity, often coexist with labral tears and typically are found in athletes.

  10. Ultrasound and Functional Assessment of Transtendinous Repairs of Partial-Thickness Articular-Sided Rotator Cuff Tears.

    PubMed

    Ostrander, Roger V; Klauser, Jeffrey M; Menon, Sanjay; Hackel, Joshua G

    2017-03-01

    Partial-thickness articular-sided rotator cuff tears are a frequent source of shoulder pain. Despite conservative measures, some patients continue to be symptomatic and require surgical management. However, there is some controversy as to which surgical approach results in the best outcomes for grade 3 tears. The purpose of this study was to evaluate repair integrity and the clinical results of patients treated with transtendinous repair of high-grade partial-thickness articular-sided rotator cuff tears. Our hypothesis was that transtendinous repairs would result in reliable healing and acceptable functional outcomes. Case series; Level of evidence, 4. Twenty patients with a minimum follow-up of 2 years were included in the study. All patients underwent arthroscopic repair of high-grade partial-thickness rotator cuff tears utilizing a transtendinous technique by a single surgeon. At latest follow-up, the repair integrity was evaluated using ultrasound imaging, and functional scores were calculated. Ultrasound evaluation demonstrated that 18 of 20 patients had complete healing with a normal-appearing rotator cuff. Two patients had a minor residual partial tear. Sixteen of 20 patients had no pain on visual analog scale. Four patients complained of mild intermittent residual pain. All patients were rated as "excellent" by both the University of California at Los Angeles Shoulder Score and the Simple Shoulder Test. The transtendon technique for the repair of articular-sided high-grade partial rotator cuff tears results in reliable tendon healing and excellent functional outcomes.

  11. The Use of an Intra-Articular Depth Guide in the Measurement of Partial Thickness Rotator Cuff Tears

    PubMed Central

    Carroll, Michael J.; More, Kristie D.; Sohmer, Stephen; Nelson, Atiba A.; Sciore, Paul; Boorman, Richard; Hollinshead, Robert; Lo, Ian K. Y.

    2013-01-01

    Purpose. The purpose of this study was to compare the accuracy of the conventional method for determining the percentage of partial thickness rotator cuff tears to a method using an intra-articular depth guide. The clinical utility of the intra-articular depth guide was also examined. Methods. Partial rotator cuff tears were created in cadaveric shoulders. Exposed footprint, total tendon thickness, and percentage of tendon thickness torn were determined using both techniques. The results from the conventional and intra-articular depth guide methods were correlated with the true anatomic measurements. Thirty-two patients were evaluated in the clinical study. Results. Estimates of total tendon thickness (r = 0.41, P = 0.31) or percentage of thickness tears (r = 0.67, P = 0.07) using the conventional method did not correlate well with true tendon thickness. Using the intra-articular depth guide, estimates of exposed footprint (r = 0.92, P = 0.001), total tendon thickness (r = 0.96, P = 0.0001), and percentage of tendon thickness torn (r = 0.88, P = 0.004) correlated with true anatomic measurements. Seven of 32 patients had their treatment plan altered based on the measurements made by the intra-articular depth guide. Conclusions. The intra-articular depth guide appeared to better correlate with true anatomic measurements. It may be useful during the evaluation and development of treatment plans for partial thickness articular surface rotator cuff tears. PMID:23533789

  12. Internal impingement in the etiology of rotator cuff tendinosis revisited.

    PubMed

    Budoff, Jeffrey E; Nirschl, Robert P; Ilahi, Omer A; Rodin, Dennis M

    2003-10-01

    The theory of internal impingement holds that, in overhead athletes, repeated contact between the undersurface of the rotator cuff and the posterosuperior glenoid rim leads to articular-sided partial-thickness rotator cuff tears and superior labral lesions. However, we have noted this same constellation of lesions in our general patient population. These recreational athletic patients do not routinely assume the position of extreme abduction and external rotation, and thus are unlikely to experience significant internal impingement forces. The goal of this study was to document the prevalence of superior labral lesions in patients being treated for partial-thickness undersurface rotator cuff tears. Retrospective case series. We retrospectively reviewed the records of 75 shoulders arthroscopically treated for partial-thickness articular-sided rotator cuff tears. With the exception of one professional tennis player, no patients were playing sports at a professional or major college level. No professional or collegiate throwing athletes were included. The prevalence of these lesions and their association with recreational athletics was noted. We found that 55 of 75 (73.3%) shoulders with articular-sided partial-thickness rotator cuff tears also had superior labral lesions. A statistically significant increased prevalence of superior labral lesions in the dominant shoulder was seen (P =.03). In addition, our patients who engaged in overhand throwing had significantly fewer superior labral lesions in the dominant shoulders than did nonthrowers (P =.017). The "kissing lesions" of undersurface rotator cuff tears and posterosuperior labral damage may be explained by mechanisms other than "internal impingement."

  13. Shoulder disorders in an outpatient clinic: an epidemiological study.

    PubMed

    Malavolta, Eduardo Angeli; Gracitelli, Mauro Emilio Conforto; Assunção, Jorge Henrique; Pinto, Gustavo de Mello Ribeiro; da Silveira, Arthur Zorzi Freire; Ferreira, Arnaldo Amado

    2017-01-01

    To describe shoulder disorders in patients evaluated by two shoulder and elbow surgeons. This cross-sectional study analyzed patients evaluated by two authors, excluding acute fractures and dislocations and patients with symptoms not involving the shoulder. Age and sex distribution was determined for the different diagnoses. We evaluated 1001 patients. Mean age was 51.43±15.15 years and 51.0% were female. Disorders of the rotator cuff occurred in 64.3% (41.2% tendinopathy, 11.0% partial tears and 12.2% full-thickness tears). Adhesive capsulitis occurred in 13.5% of cases and glenohumeral instability in 8.1%. Rotator cuff disorders were more common in women, with a peak between 50 and 59 years for tendinopathy and partial tears and between 60 and 69 years for full-thickness tears. Glenohumeral instability was more frequent in men, with a peak between 30 and 39 years. The most frequent diagnosis was rotator cuff tendinopathy, followed by adhesive capsulitis, full-thickness rotator cuff tears, partial rotator cuff tears and glenohumeral instability. Rotator cuff lesions were more common in women, with a peak between 60 and 69 years for full-thickness tears. Level of Evidence IV, Case Series.

  14. Status of the contralateral rotator cuff in patients undergoing rotator cuff repair.

    PubMed

    Ro, Kyung-Han; Park, Jong-Hoon; Lee, Soon-Hyuck; Song, Dong-Ik; Jeong, Ha-Joon; Jeong, Woong-Kyo

    2015-05-01

    Although the prevalence of rotator cuff tear (RCT) in the general population has been analyzed, little information is available on the status of the opposite-side rotator cuff in patients who have undergone arthroscopic rotator cuff repair. To identify the characteristics of the contralateral shoulder and to identify factors associated with RCT of the contralateral shoulder in patients who underwent surgery for symptomatic RCT. The hypothesis was that the prevalence of RCT in the contralateral shoulder would be higher in patients with increasingly larger cuff tears requiring surgical intervention. Case series; Level of evidence, 4. The study cohort consisted of 140 patients with RCT who underwent arthroscopic rotator cuff repair. Opposite-shoulder rotator cuff tendons of all patients were evaluated by ultrasonography. Demographic information and factors related to contralateral RCT were investigated, and risk factors associated with contralateral RCT were assessed. Of the 140 patients who underwent arthroscopic rotator cuff repair, 54 (38.6%) had an RCT of the contralateral shoulder. Of 51 patients with partial-thickness and small-sized full-thickness tears of the operated shoulder, 35 (68.6%) had no tears; 14 (27.5%) had partial-thickness tears; and 2 (3.9%) had small-sized full-thickness tears of the contralateral shoulder. Of 75 patients with medium-sized full-thickness tears, 43 (57.3%) had no tears; 12 (16%) had partial-thickness tears; and 20 (26.7%) had full-thickness tears of the contralateral shoulder. Of 14 patients with large to massive full-thickness tears, 8 (57.1%) had no tears; 1 (7.1%) had a partial-thickness tear; and 5 (35.7%) had full-thickness tears of the contralateral shoulder. The prevalence of RCT of the contralateral shoulder differed significantly among groups classified by tear size (P=.007). The mean American Shoulder and Elbow Surgeons score was significantly lower in the RCT than in the nontear group (55.8±16.9 vs 61.6±13.3; P=.03). Of 29 subjects with symptomatic tears involving the nondominant arm, 17 (58.6%) had contralateral asymptomatic RCT, compared with 37 of 111 (33.3%) subjects with symptomatic tears involving the dominant arm (P=.007). The prevalence of RCT of the contralateral asymptomatic shoulder tends to be higher in patients with more symptomatic RCT on one side, in patients with medium-sized or larger RCT in the operated shoulder, and in patients with symptomatic RCT in the nondominant arm. © 2015 The Author(s).

  15. Detection of partial-thickness tears in ligaments and tendons by Stokes-polarimetry imaging

    NASA Astrophysics Data System (ADS)

    Kim, Jihoon; John, Raheel; Walsh, Joseph T.

    2008-02-01

    A Stokes polarimetry imaging (SPI) system utilizes an algorithm developed to construct degree of polarization (DoP) image maps from linearly polarized light illumination. Partial-thickness tears of turkey tendons were imaged by the SPI system in order to examine the feasibility of the system to detect partial-thickness rotator cuff tear or general tendon pathology. The rotating incident polarization angle (IPA) for the linearly polarized light provides a way to analyze different tissue types which may be sensitive to IPA variations. Degree of linear polarization (DoLP) images revealed collagen fiber structure, related to partial-thickness tears, better than standard intensity images. DoLP images also revealed structural changes in tears that are related to the tendon load. DoLP images with red-wavelength-filtered incident light may show tears and related organization of collagen fiber structure at a greater depth from the tendon surface. Degree of circular polarization (DoCP) images exhibited well the horizontal fiber orientation that is not parallel to the vertically aligned collagen fibers of the tendon. The SPI system's DOLP images reveal alterations in tendons and ligaments, which have a tissue matrix consisting largely of collagen, better than intensity images. All polarized images showed modulated intensity as the IPA was varied. The optimal detection of the partial-thickness tendon tears at a certain IPA was observed. The SPI system with varying IPA and spectral information can improve the detection of partial-thickness rotator cuff tears by higher visibility of fiber orientations and thereby improve diagnosis and treatment of tendon related injuries.

  16. Débridement of Small Partial-thickness Rotator Cuff Tears in Elite Overhead Throwers

    PubMed Central

    Dugas, Jeffrey R.; Cain, E. Lyle; McMichael, Christopher S.; Andrews, James R.

    2008-01-01

    Elite overhead throwing athletes with rotator cuff tears represent a unique group of patients with an ultimate goal of returning to their previous level of competition. We hypothesized débridement of small partial-thickness rotator cuff tears would return the majority of elite overhead throwing athletes to their previous level of competition. Preoperative and intraoperative findings on 82 professional pitchers who had undergone débridement of partial-thickness rotator cuff tears were evaluated using our database. We obtained return to play data on 67 of the 82 players (82%); 51 (76%) were able to return to competitive pitching at the professional level and 37 (55%) were able to return to the same or higher level of competition. Of the 67 patients, 34 pitchers returned a questionnaire with a minimum followup of 18 months (mean 38 months; range 18 to 59 months). SF-12 scores were above average with a mean PSF-12 and MSF-12 of 55.04 and 56.49 respectively. An Athletic Shoulder Outcome Rating Scale score of greater than 60 was found in 76.5% of pitchers. Débridement of small partial-thickness rotator cuff tears allowed a majority of elite overhead throwing athletes to return to competitive pitching, however, returning to their previous level of competition remains a challenge for many of these players. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18264849

  17. Learning curve of office-based ultrasonography for rotator cuff tendons tears.

    PubMed

    Ok, Ji-Hoon; Kim, Yang-Soo; Kim, Jung-Man; Yoo, Tae-Wook

    2013-07-01

    To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard. The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement. The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners. The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint. Diagnostic study, Level II.

  18. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model.

    PubMed

    Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul

    2015-11-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.

  19. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model

    PubMed Central

    Park, Gi-Young; Lee, Sang Chul

    2015-01-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340

  20. The Effects of Posterior Rotator Cuff Cable Tears on Glenohumeral Biomechanics in a Cadaveric Model of the Throwing Shoulder

    PubMed Central

    Photopoulos, Christos Demetris; ElAttrache, Neal S.; Doermann, Alex; Akeda, Masaki; McGarry, Michelle H.; Lee, Thay Q.

    2017-01-01

    Objectives: The rotator cuff cable has been postulated to be the primary load bearing substructure of the superior part of the rotator cuff. Tears of the posterior rotator cable are frequently seen in overhead throwing athletes. Although the biomechanical significance of the anterior rotator cable has been well described, our current understanding of the relevance of the posterior cable is limited. The purpose of this study was to examine how partial-thickness tears and full-thickness tears of the posterior rotator cable would alter glenohumeral biomechanics and kinematics in cadaveric shoulder models. Methods: Eight fresh-frozen cadaveric shoulder specimens were prepared and tested. To simulate the sequence of glenohumeral positions during the throwing motion, specimens were mounted on a custom shoulder testing system with the humerus positioned at 90° of abduction (30° scapular upward rotation, 60° glenohumeral abduction) and tested at 30, 60, 90, and 120 degrees of external rotation. After a circumferential capsulotomy was performed, rotator cuff muscles were loaded based on physiologic cross-sectional area ratios, and testing for each specimen was performed on each the following three conditions: intact posterior cable, partial-thickness (50%) articular-sided posterior cable tear, and full-thickness posterior cable tear. Primary outcome measures tested for each condition under the various degrees of glenohumeral rotation were: 1) anterior and total glenohumeral translation after application of a 30N anterior force; 2) path of glenohumeral articulation; 3) glenohumeral joint force. Results: With a 30N anterior force at 120° of external rotation, there was a significant increase in anterior glenohumeral translation between intact and full-thickness tear specimens (7.28±2.00mm and 17.49±3.75mm, respectively; p<0.05). Similarly, total joint translation at 120° of external rotation significantly increased between intact and full-thickness tear specimens (10.37±3.18mm and 23.37±5.05mm, respectively; p<0.05). No significant differences were apparent at other degrees of rotation (30, 60, 90 degrees), or with partial-thickness tears. Changes in the path of glenohumeral articulation were likewise most evident at 120° of external rotation, with a progressively anterior, inferior, and lateral shift in articulation with sequential sectioning of the posterior cable. Lastly, with regards to alterations in glenohumeral joint force, no significant changes were seen in any of the conditions. Conclusion: In this cadaveric shoulder model of the throwing shoulder, tears of the posterior rotator cuff cable lead to altered glenohumeral biomechanics and kinematics. These changes were most profound at 120° of external rotation, suggesting the importance of an intact posterior cable as a potential stabilizer during the late-cocking phase of throwing.

  1. Surgical correction of cryptotia combined with an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap.

    PubMed

    Yu, Xiaobo; Yang, Qinghua; Jiang, Haiyue; Pan, Bo; Zhao, Yanyong; Lin, Lin

    2017-11-01

    Cryptotia is a common congenital ear deformity in Asian populations. In cryptotia, a portion of the upper ear is hidden and fixed in a pocket of the skin of the mastoid. Here we describe our method for cryptotia correction by using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap. We developed a new method for correcting cryptotia by using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap. Following ear release, the full-thickness skin rotation flap is rotated into the defect, and the donor site is covered with an ultra-delicate split-thickness skin graft raised in continuity with the flap. All patients exhibited satisfactory release of cryptotia. No cases involved partial or total flap necrosis, and post-operative outcomes using this new technique for cryptotia correction have been more than satisfactory. Our method of using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap to correct cryptotia is simple and reliable. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. The incidence and effect of fatty atrophy, positive tangent sign, and rotator cuff tears on outcomes after total shoulder arthroplasty.

    PubMed

    Choate, W Stephen; Shanley, Ellen; Washburn, Richard; Tolan, Stefan J; Salim, Tariq I; Tadlock, Josh; Shealy, Elizabeth C; Long, Catherine D; Crawford, Ashley E; Kissenberth, Michael J; Lonergan, Keith T; Hawkins, Richard J; Tokish, John M

    2017-12-01

    Treatment choices for total shoulder arthroplasty (TSA) in the absence of full-thickness rotator cuff tears (RCTs) are not clearly defined in current literature. This study investigated the prevalence and effect of preoperative partial-thickness RCTs and muscular degenerative changes on postoperative outcomes after TSA. Medical records and magnetic resonance imaging studies were reviewed for patients who underwent TSA for primary glenohumeral osteoarthritis with minimum 2-year follow-up to determine preoperative tear classification, Goutallier grade, and supraspinatus tangent sign. Postoperative pain on the visual analog scale, range of motion, and patient outcomes scores were obtained to correlate preoperative RCT status, Goutallier grading, tangent sign, and postoperative outcomes. Patients with full-thickness RCT on preoperative magnetic resonance imaging were excluded. Forty-five patients met all inclusion criteria (average age, 65 ± 10 years; average follow-up, 43 months). Of the patients undergoing TSA, 40% had a significant (>50% thickness) partial RCT. Grade 3 to 4 Goutallier changes were noted in 22% of all patients, and 13% demonstrated grade 3 to 4 changes in the context of no tear. Positive tangent sign was present in 7% of all patients. The preoperative Goutallier grade of the infraspinatus was significantly negatively correlated with postoperative forward elevation (P = .02) and external rotation (P = .05), but rotator cuff pathology, including tear status, Goutallier grade, and the presence of a tangent sign, did not correlate with postoperative functional outcome scores. Even in the absence of a full-thickness RCT, rotator cuff atrophy, fatty infiltration, and partial thickness tearing are common findings. Although postoperative range of motion is correlated to Goutallier changes of the infraspinatus, rotator cuff pathology is not correlated to outcomes after TSA; therefore, one may proceed with TSA without concern of their effect on postoperative outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Clinical Outcomes of Modified Mason-Allen Single-Row Repair for Bursal-Sided Partial-Thickness Rotator Cuff Tears: Comparison With the Double-Row Suture-Bridge Technique.

    PubMed

    Shin, Sang-Jin; Kook, Seung-Hwan; Rao, Nandan; Seo, Myeong-Jae

    2015-08-01

    Various repair techniques have been reported for the operative treatment of bursal-sided partial-thickness rotator cuff tears. Recently, arthroscopic single-row repair using a modified Mason-Allen technique has been introduced. The arthroscopic, modified Mason-Allen single-row technique with preservation of the articular-sided tendon provides satisfactory clinical outcomes and similar results to the double-row suture-bridge technique after conversion of a partial-thickness tear to a full-thickness tear. Cohort study; Level of evidence, 3. A retrospective study was conducted on 84 consecutive patients with symptomatic, bursal-sided partial-thickness rotator cuff tears involving more than 50% thickness of the tendon. A total of 47 patients were treated by the modified Mason-Allen single-row repair technique, preserving the articular-sided tendon, and 37 patients were treated by the double-row suture-bridge repair technique after conversion to a full-thickness tear. The clinical and functional outcomes were evaluated using the American Shoulder and Elbow Surgeons (ASES) and Constant scores and a visual analog scale (VAS) for pain and satisfaction of patients. Magnetic resonance imaging (MRI) was used to analyze the integrity of tendons at 6-month follow-up. Patients were followed up for a mean of 32.5 months. In the 47 patients treated with the modified Mason-Allen suture technique, the VAS score decreased from a preoperative mean of 5.3 ± 0.3 to 0.9 ± 0.5 at the time of final follow-up. There was a statistically significant increase in the mean ASES score (from 45.4 ± 2.9 to 88.6 ± 4.5) and mean Constant score (from 66.9 ± 2.6 to 88.1 ± 2.4) (P < .001). Four of 47 patients (8.5%) demonstrated retears at 6-month postoperative MRI. There was no statistical difference in terms of functional outcomes and the retear rate compared with those of patients with the suture-bridge repair technique (3 patients, 8.1%). However, the mean number of suture anchors used in the patients with modified Mason-Allen suture repair (1.2 ± 0.4) was significantly fewer than that in the patients with suture-bridge repair (3.2 ± 0.4) (P < .01). The modified Mason-Allen single-row repair technique that preserved the articular-sided tendon provided satisfactory clinical outcomes in patients with symptomatic, bursal-sided partial-thickness rotator cuff tears. Despite a fewer number of suture anchors, the shoulder functional outcomes and retear rate in patients after modified Mason-Allen repair were comparable with those of patients who underwent double-row suture-bridge repair. Therefore, the modified Mason-Allen single-row repair technique using a triple-loaded suture anchor can be considered as an effective treatment in patients with bursal-sided partial-thickness rotator cuff tears. © 2015 The Author(s).

  4. Radiographic progression of arthritic changes in shoulders with degenerative rotator cuff tears.

    PubMed

    Chalmers, Peter N; Salazar, Dane H; Steger-May, Karen; Chamberlain, Aaron M; Stobbs-Cucchi, Georgia; Yamaguchi, Ken; Keener, Jay D

    2016-11-01

    Very little longitudinal information has been available regarding the relationship of cuff tears and arthritis. The purpose of this study was to determine the midterm risk of and risk factors for rotator cuff tear arthropathy progression in a cohort of subjects with an asymptomatic rotator cuff tear. Baseline (visit 1), 5-year (visit 2), and most recent follow-up (visit 3) radiographs were reviewed in a cohort of 105 subjects enrolled for longitudinal surveillance of asymptomatic degenerative rotator cuff tears and 33 controls. The radiographs were assessed in a blinded, randomized fashion by 3 observers who graded glenohumeral arthritic changes using the Hamada scores, Samilson-Prieto (SPO) scores, and acromiohumeral interval (AHI). Osteoarthritis (SPO classification), cuff tear arthropathy (Hamada classification), and AHI progressed between visits 1 and 3 (median, 8 years; P < .001 in all cases). SPO progression was not significantly different for partial- vs. full-thickness vs. control baseline tear types (P = .19). Both full-thickness and partial-thickness tears had greater progression in Hamada scores than controls did in the first 5 years of follow-up (P = .02 and P = .03, respectively), but scores did not differ between partial- and full-thickness tears. Tears with and without enlargement did not differ in progression in SPO grade, Hamada grade, or AHI. Glenohumeral arthritic changes progress significantly but remain minimal within an 8-year period in early to moderate degenerative cuff disease. Whereas the presence of a rotator cuff tear influences progression in Hamada grade, the magnitude of radiographic progression is not influenced by tear severity or enlargement at midterm time points. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. Improved apparatus for predictive diagnosis of rotator cuff disease

    NASA Astrophysics Data System (ADS)

    Pillai, Anup; Hall, Brittany N.; Thigpen, Charles A.; Kwartowitz, David M.

    2014-03-01

    Rotator cuff disease impacts over 50% of the population over 60, with reports of incidence being as high as 90% within this population, causing pain and possible loss of function. The rotator cuff is composed of muscles and tendons that work in tandem to support the shoulder. Heavy use of these muscles can lead to rotator cuff tear, with the most common causes is age-related degeneration or sport injuries, both being a function of overuse. Tears ranges in severity from partial thickness tear to total rupture. Diagnostic techniques are based on physical assessment, detailed patient history, and medical imaging; primarily X-ray, MRI and ultrasonography are the chosen modalities for assessment. The final treatment technique and imaging modality; however, is chosen by the clinician is at their discretion. Ultrasound has been shown to have good accuracy for identification and measurement of full-thickness and partial-thickness rotator cuff tears. In this study, we report on the progress and improvement of our method of transduction and analysis of in situ measurement of rotator cuff biomechanics. We have improved the ability of the clinician to apply a uniform force to the underlying musculotendentious tissues while simultaneously obtaining the ultrasound image. This measurement protocol combined with region of interest (ROI) based image processing will help in developing a predictive diagnostic model for treatment of rotator cuff disease and help the clinicians choose the best treatment technique.

  6. Editorial Commentary: Subacromial Decompression Is Unnecessary in Most Routine Rotator Cuff Repairs.

    PubMed

    Solomon, Daniel J

    2017-07-01

    There is no need to perform subacromial decompression in partial bursal-sided rotator cuff repairs to obtain a good result. This, paired with the findings of previous studies of full-thickness rotator cuff repairs, suggests that extrinsic factors rarely affect the rotator cuff. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Early postoperative repair status after rotator cuff repair cannot be accurately classified using questionnaires of patient function and isokinetic strength evaluation.

    PubMed

    Colliver, Jessica; Wang, Allan; Joss, Brendan; Ebert, Jay; Koh, Eamon; Breidahl, William; Ackland, Timothy

    2016-04-01

    This study investigated if patients with an intact tendon repair or partial-thickness retear early after rotator cuff repair display differences in clinical evaluations and whether early tendon healing can be predicted using these assessments. We prospectively evaluated 60 patients at 16 weeks after arthroscopic supraspinatus repair. Evaluation included the Oxford Shoulder Score, 11-item version of the Disabilities of the Arm, Shoulder and Hand, visual analog scale for pain, 12-item Short Form Health Survey, isokinetic strength, and magnetic resonance imaging (MRI). Independent t tests investigated clinical differences in patients based on the Sugaya MRI rotator cuff classification system (grades 1, 2, or 3). Discriminant analysis determined whether intact repairs (Sugaya grade 1) and partial-thickness retears (Sugaya grades 2 and 3) could be predicted. No differences (P < .05) existed in the clinical or strength measures. Although discriminant analysis revealed the 11-item version of the Disabilities of the Arm, Shoulder and Hand produced a 97% true-positive rate for predicting partial thickness retears, it also produced a 90% false-positive rate whereby it incorrectly predicted a retear in 90% of patients whose repair was intact. The ability to discriminate between groups was enhanced with up to 5 variables entered; however, only 87% of the partial-retear group and 36% of the intact-repair group were correctly classified. No differences in clinical scores existed between patients stratified by the Sugaya MRI classification system at 16 weeks. An intact repair or partial-thickness retear could not be accurately predicted. Our results suggest that correct classification of healing in the early postoperative stages should involve imaging. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliver, J. B.

    Planetary substrate rotation for optical-coating deposition is evaluated based on initial and final positions for a given layer with different numbers of revolutions and various deposition-source locations. The influence of partial revolutions of the rotation system is analyzed relative to the total number of planetary revolutions in that layer to determine the relative impact on film thickness and uniformity. Furthermore, guidance is provided on the necessary planetary revolutions that should take place in each layer versus the expected error level in the layer thickness for the modeled system.

  9. Impact of non-integer planetary revolutions on the distribution of evaporated optical coatings

    DOE PAGES

    Oliver, J. B.

    2017-02-08

    Planetary substrate rotation for optical-coating deposition is evaluated based on initial and final positions for a given layer with different numbers of revolutions and various deposition-source locations. The influence of partial revolutions of the rotation system is analyzed relative to the total number of planetary revolutions in that layer to determine the relative impact on film thickness and uniformity. Furthermore, guidance is provided on the necessary planetary revolutions that should take place in each layer versus the expected error level in the layer thickness for the modeled system.

  10. Arthroscopy and the Dramatic Increase in Frequency of Anterior Acromioplasty from 1980 to 2005: An Epidemiologic Study

    PubMed Central

    Yu, Elizabeth; Cil, Akin; Harmsen, William Scott; Schleck, Cathy; Sperling, John W.; Cofield, Robert H.

    2011-01-01

    Purpose The purpose of this study is to better understand the utilization of anterior acromioplasty over time – in the absence of rotator cuff repair, to examine the relationship to patient characteristics (age, sex) and types of rotator cuff pathology (inflammation or fibrosis, partial thickness tearing, full thickness tearing undergoing debridement), and to assess the utilization of arthroscopy in this procedure. Methods Using the resources of the Rochester Epidemiology Project, cataloging medical records of residents in Olmsted County, Minnesota, we identified 246 patients who underwent anterior acromioplasty between 1980 and 2005. It has previously been shown that rarely does a resident of Olmsted County undergo an orthopedic procedure at a facility outside the county. Results The incidence of anterior acromioplasty increased over time (p<0.001) with the crude rate of 3.3 per 100,000 in 1980 to 1985 to 19.0 per 100,000 in 2000 to 2005. Sex, age, and types of rotator cuff pathology did not significantly change over the twenty-six year period. There was a dramatic shift from use of the open to the arthroscopic approach over this time period (p<0.001) and a decrease in the concomitant performance of distal clavicle resection (p<0.001). Conclusions The frequency of anterior acromioplasty has dramatically increased over time. Increasing knowledge about this syndrome, including better imaging, has facilitated patient treatment for a stable spectrum of rotator cuff pathology (inflammation or fibrosis, partial thickness tearing, full thickness tearing undergoing debridement), as has the application of endoscopic surgery. PMID:20691562

  11. Clinical Results of Platelet-Rich Plasma for Partial Thickness Rotator Cuff Tears: A Case Series.

    PubMed

    Zafarani, Zohreh; Mirzaee, Fateme; Guity, Mohamadreza; Aslani, Hamidreza

    2017-09-01

    Partial thickness rotator cuff tears (PTRCTs) are a common pathology among shoulder disorders in people over 50 years. Treatment of PTRCTs remains controversial. Most studies on the treatment of PTRCTs have explained surgical techniques or outcomes; few studies have centralized on the conservative and new management of PTRCTs, like treatment with Platelet-rich plasma (PRP). These case series study have been conducted on Platelet-rich plasma (PRP) injection, as a concentrated source of cytokines that can stimulate healing of soft tissue. PRP injection showed positive effect on improving PTRCTs complains. This method improved pain, function, DASH score and shoulder joint range motion in. Because of PRP products are safe and easy to prepare and apply, and also according to improving patient's condition, this method can be used to treat PTRCTs.

  12. Smoking and morphology of calcific deposits affect the outcome of needle aspiration of calcific deposits (NACD) for calcific tendinitis of the rotator cuff.

    PubMed

    Oudelaar, Bart W; Ooms, Edwin M; Huis In 't Veld, Rianne M H A; Schepers-Bok, Relinde; Vochteloo, Anne J

    2015-11-01

    Although NACD has proven to be an effective minimal invasive treatment for calcific tendinitis of the rotator cuff, little is known about the factors associated with treatment failure or the need for multiple procedures. Patients with symptomatic calcific tendinitis who were treated by NACD were evaluated in a retrospective cohort study. Demographic details, medical history, sonographic and radiographic findings were collected from patient files. Failure of NACD was defined as the persistence of symptoms after a follow-up of at least six months. NACD procedures performed within six months after a previous NACD procedure were considered repeated procedures. Multivariate logistic regression analysis was used to determine factors associated with treatment failure and multiple procedures. 431 patients (277 female; mean age 51.4±9.9 years) were included. Smoking (adjusted odds ratio (AOR): 1.7, 95% CI 1.0-2.7, p=0.04) was significantly associated with failure of NACD. Patients with Gärtner and Heyer (GH) type I calcific deposits were more likely to need multiple NACD procedures (AOR: 3.4, 95% CI 1.6-7.5, p<0.01) compared to patients with type III calcific deposits. Partial thickness rotator cuff tears were of no influence on the outcome of NACD or the number of treatments necessary. Smoking almost doubled the chance of failure of NACD and the presence of GH type I calcific deposits significantly increased the chance of multiple procedures. Partial thickness rotator cuff tears did not seem to affect the outcome of NACD. Based on the findings in this study, the importance of quitting smoking should be emphasized prior to NACD and partial thickness rotator cuff tears should not be a reason to withhold patients NACD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Dedicated training program for shoulder sonography: the results of a quality program reverberate with everyone.

    PubMed

    Delzell, Patricia B; Boyle, Alex; Schneider, Erika

    2015-06-01

    The purpose of this study was to define and report on the effect of a comprehensive musculoskeletal sonography training program to improve accuracy (sensitivity and specificity) for the diagnosis of rotator cuff tears in relatively inexperienced operators. Before the training program was implemented, radiologists (n = 12) had a mean of 2 years (range, <1-12 years) of experience performing and interpreting musculoskeletal sonography. Pre- and post-training shoulder sonographic results were compared to surgical reports or, in their absence, to shoulder magnetic resonance imaging or computed tomographic arthrographic results if within 2 months of the sonographic examination. A total of 82 patients were included in the pre-training group (January 2010-December 2011), and 50 patients were included in the post-training group (January 2012-June 2013). The accuracy, sensitivity, specificity, and positive and negative predictive values were determined for the presence or absence of supraspinatus and infraspinatus tendon tears. After implementation of the training program, the sensitivity of sonography for detecting full-thickness rotator cuff tears increased by 14%, and the sensitivity for detecting partial-thickness rotator cuff tears increased by 3%. Quality improvement programs and acquisition standardization along with ongoing, focused case conferences for the entire care team increased the sensitivity of shoulder sonography for diagnosing both full- and partial-thickness rotator cuff tears, independent of the years of operator experience. © 2015 by the American Institute of Ultrasound in Medicine.

  14. Preservation of bursal-sided tendon in partial-thickness articular-sided rotator cuff tears: a novel arthroscopic transtendon anatomic repair technique.

    PubMed

    Shin, Sang-Jin; Jeong, Jae-Hoon; Jeon, Yoon Sang; Kim, Rag Gyu

    2016-12-01

    The purpose of this study was to introduce a novel arthroscopic transtendon anatomic repair technique that spares the intact bursal-sided tendon in articular-sided partial-thickness rotator cuff tears (PTRCT) and to present shoulder functional outcomes in patients with symptomatic articular-sided PCRCT that involves more than 50 % of its thickness after arthroscopic repair using a novel technique. Eighteen patients with symptomatic articular-sided PCRCT involving more than 50 % of the tendon's thickness underwent arthroscopic repair using a devised technique. The devised technique restores only the torn articular portion of the rotator cuff at the anatomical footprint using a suture anchor, and preserves the integrity of the corresponding bursal-sided tendon by tying knots at the most lateral bursal side on the subacromial space. Clinical and functional outcome using ASES and Constant scores were evaluated. The structural integrity of the rotator cuff was evaluated by MRI at 6 months postoperatively. Pain relief and shoulder functional outcomes were encouraging during the recovery phase after operation. ASES (preoperative 54.0 ± 10.3 to postoperative 92.6 ± 8.0), Constant score (61.2 ± 8.5-88.0 ± 5.3), VAS for pain (4.9 ± 2.6-0.6 ± 0.7) improved significantly after arthroscopic transtendon anatomic repair (p < 0.001). No patients had rotator cuff retears on 6-month MRI. No complications related to surgical procedures had occurred. The devised technique of arthroscopic transtendon repair provided satisfactory functional outcomes without postoperative discomforts. This technique minimizes over-tightening of the articular layer and reduces tension mismatches between the articular and bursal layers, which are considered as important factors for improvement of postoperative shoulder motion.

  15. The Superior Labrum, Anterior-to-Posterior ’SLAP’ Lesion

    DTIC Science & Technology

    2006-10-01

    and optimize surgical outcomes. Shoulder arthroscopy is the mainstay of diagnosis and treatment for most patients with SLAP lesions (1). A...complete diagnostic arthroscopy should include an inspection of the rotator cuff for associated partial thickness or full- thickness tears and inspection of...Karzel RP, Del Pizzo, W, et al: SLAP lesions of the shoulder. Arthroscopy 1990; 6:274-279. 2 Sanders TG, Morrison WB, and Miller, MD: Imaging

  16. Ultrasound evaluation of arthroscopic full-thickness supraspinatus rotator cuff repair: single-row versus double-row suture bridge (transosseous equivalent) fixation. Results of a prospective, randomized study.

    PubMed

    Gartsman, Gary M; Drake, Gregory; Edwards, T Bradley; Elkousy, Hussein A; Hammerman, Steven M; O'Connor, Daniel P; Press, Cyrus M

    2013-11-01

    The purpose of this study was to compare the structural outcomes of a single-row rotator cuff repair and double-row suture bridge fixation after arthroscopic repair of a full-thickness supraspinatus rotator cuff tear. We evaluated with diagnostic ultrasound a consecutive series of ninety shoulders in ninety patients with full-thickness supraspinatus tears at an average of 10 months (range, 6-12) after operation. A single surgeon at a single hospital performed the repairs. Inclusion criteria were full-thickness supraspinatus tears less than 25 mm in their anterior to posterior dimension. Exclusion criteria were prior operations on the shoulder, partial thickness tears, subscapularis tears, infraspinatus tears, combined supraspinatus and infraspinatus repairs and irreparable supraspinatus tears. Forty-three shoulders were repaired with single-row technique and 47 shoulders with double-row suture bridge technique. Postoperative rehabilitation was identical for both groups. Ultrasound criteria for healed repair included visualization of a tendon with normal thickness and length, and a negative compression test. Eighty-three patients were available for ultrasound examination (40 single-row and 43 suture-bridge). Thirty of 40 patients (75%) with single-row repair demonstrated a healed rotator cuff repair compared to 40/43 (93%) patients with suture-bridge repair (P = .024). Arthroscopic double-row suture bridge repair (transosseous equivalent) of an isolated supraspinatus rotator cuff tear resulted in a significantly higher tendon healing rate (as determined by ultrasound examination) when compared to arthroscopic single-row repair. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  17. Arthroscopic rotator cuff debridement without decompression for the treatment of tendinosis.

    PubMed

    Budoff, Jeffrey E; Rodin, Dennis; Ochiai, Derek; Nirschl, Robert P

    2005-09-01

    The treatment of rotator cuff injury in the absence of a full-thickness tear has traditionally consisted of acromioplasty. However, this disorder may also be treated by arthroscopic rotator cuff debridement without acromioplasty. Our previous study of 79 shoulders so treated reported 87% good or excellent results at an average 53-month follow-up. The purpose of this article is to report the long-term, average 9.5-year follow-up of this cohort. Long-term follow-up of case series. We retrospectively reviewed the records of 62 shoulders in 60 patients who had undergone arthroscopic rotator cuff debridement for partial-thickness rotator cuff tears. Demographic criteria, residual pain, and the ability to return to recreational athletics were noted. The UCLA Shoulder Score and the Simple Shoulder Test scores were determined and statistical analysis performed. Using the UCLA Shoulder Score, there were 79% excellent or good results at an average 114 months of follow-up. Patients with Workers' Compensation claims had significantly worse results, with only 40% rated good or excellent. Of the 60 patients, 77% had no or only minimal pain, 57% were still able to perform recreational athletics without difficulty, and 20% could participate at a lower level of intensity. Arthroscopic debridement of rotator cuff injury in the absence of a full-thickness tear has good long-term results and minimizes additional surgical trauma. Level IV, case series.

  18. Asymptomatic rotator cuff tears: Patient demographics and baseline shoulder function

    PubMed Central

    Keener, Jay D.; Steger-May, Karen; Stobbs, Georgia; Yamaguchi, Ken

    2010-01-01

    Background The purpose of this study is to characterize the demographic features and physical function of subjects with asymptomatic rotator cuff tears and to compare their shoulder function to controls with an intact rotator cuff. Materials and Methods 196 subjects with an asymptomatic rotator cuff tear and 54 subjects with an intact rotator cuff presenting with a painful rotator cuff tear in the contralateral shoulder were enrolled. Various demographic features, shoulder function (ASES score and SST score), range of motion and strength were compared. Results The demographic features of the study and control groups were similar. Hand dominance was associated with the presence of shoulder pain (p < .05). Subjects with an intact rotator cuff had greater but clinically insignificant ASES (p < .05) and SST scores (p < .05) than those with an asymptomatic tear. No differences in functional scores, range of motion or strength were seen between partial (n=61) and full-thickness tears (n=135). Of the full-thickness tears, 36 (27%) were classified as small, 85 (63%) as medium and 14 (10%) as large tears. No differences were seen in functional scores between full-thickness tears of various sizes. Conclusions When asymptomatic, a rotator cuff tear is associated with a clinically insignificant loss of shoulder function compared to those with an intact rotator cuff. Therefore, a clinically detectable decline in shoulder function may indicate an “at-risk” asymptomatic tear. The presence of pain is important in cuff deficient shoulders for creating a measurable loss of shoulder function. Hand dominance appears to be an important risk factor for pain. PMID:21030274

  19. Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs.

    PubMed

    Le, Brian T N; Wu, Xiao L; Lam, Patrick H; Murrell, George A C

    2014-05-01

    The rate of retears after rotator cuff repair varies from 11% to 94%. A retear is associated with poorer subjective and objective clinical outcomes than intact repair. This study was designed to determine which preoperative and/or intraoperative factors held the greatest association with retears after arthroscopic rotator cuff repair. Cohort study; Level of evidence, 3. This study retrospectively evaluated 1000 consecutive patients who had undergone a primary rotator cuff repair by a single surgeon using an arthroscopic inverted-mattress knotless technique and who had undergone an ultrasound evaluation 6 months after surgery to assess repair integrity. Exclusion criteria included previous rotator cuff repair on the same shoulder, incomplete repair, and repair using a synthetic polytetrafluoroethylene patch. All patients had completed the modified L'Insalata Questionnaire and underwent a clinical examination before surgery. Measurements of tear size, tear thickness, associated shoulder injury, tissue quality, and tendon mobility were recorded intraoperatively. The overall retear rate at 6 months after surgery was 17%. Retears occurred in 27% of full-thickness tears and 5% of partial-thickness tears (P < .0001). The best independent predictors of retears were anteroposterior tear length (correlation coefficient r = 0.41, P < .0001), tear size area (r = 0.40, P < .0001), mediolateral tear length (r = 0.34, P < .0001), tear thickness (r = 0.29, P < .0001), age at surgery (r = 0.27, P < .0001), and operative time (r = 0.18, P < .0001). These factors produced a predictive model for retears: logit P = (0.039 × age at surgery in years) + (0.027 × tear thickness in %) + (1 × anteroposterior tear length in cm) + (0.76 × mediolateral tear length in cm) - (0.17 × tear size area in cm(2)) + (0.018 × operative time in minutes) -9.7. Logit P can be transformed into P, which is the chance of retears at 6 months after surgery. A rotator cuff retear is a multifactorial process with no single preoperative or intraoperative factor being overwhelmingly predictive of it. Nevertheless, rotator cuff tear size (tear dimensions, tear size area, and tear thickness) showed stronger associations with retears at 6 months after surgery than did measures of tissue quality and concomitant shoulder injuries.

  20. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  1. Posterior capsular fibrosis in professional baseball pitchers: case series of MR arthrographic findings in six patients with glenohumeral internal rotational deficit.

    PubMed

    Tehranzadeh, Arash D; Fronek, Jan; Resnick, Donald

    2007-01-01

    In the high-performance athlete, acquired thickening of the posterior joint capsule is a proposed etiology for glenohumeral internal rotational deficit (GIRD). The purpose of this study was to present our MR arthrographic imaging observations of posterior capsular thickening in professional baseball players who present with reduced throwing velocity related to pain and clinical findings of internal rotational deficit of the glenohumeral joint. Our observations of MR imaging features in patients with clinical and arthroscopic manifestations of GIRD lesions include articular surface partial thickness tears of the supraspinatus and infraspinatus tendons, superoposterior subluxation of the humeral head and SLAP tears of the labrum. Although no empiric standard currently exists for the axial dimension thickness of the shoulder capsule, we have observed a thickened appearance of the posterior band of the inferior glenohumeral ligament in these patients.

  2. Aquarium Portal Technique for PASTA Lesion Repair.

    PubMed

    Meyer, Dominik C; Gerber, Christian; Familiari, Filippo

    2017-10-01

    The simultaneous arthroscopic exposure of the subacromial and intra-articular space of the shoulder is challenging in the presence of only partial-thickness rotator cuff tears. We present our experience and method of entering the joint through the opened rotator cuff interval from an anterosuperior portal between the coracoid process and anterior acromion. With moderate (approximately 30°) abduction and external rotation, the rotator interval opens readily, offering a view with the camera toward the anterior edge of the supraspinatus tendon. An anterior view on the anterior leading edge of the supraspinatus tendon is obtained, showing the subacromial space above and the glenohumeral space below the tendon, similar to the view in an aquarium. The rotator cuff can be elevated using a rod inserted intra-articularly from posterior, whereas anchors and other instruments may be inserted from lateral. This approach offers the advantages of full exposure of the posterior undersurface of the rotator cuff insertion; a convenient approximately 90° angle between the camera and instruments; and no need to change portals for anchor placement, tendon stitching, or suture handling. The objective of this Technical Note is to describe our arthroscopic repair approach (aquarium technique) to PASTA (partial articular supraspinatus tendon avulsion) lesions.

  3. Estimating the Minimal Important Difference for the Western Ontario Rotator Cuff Index (WORC) in adults with shoulder pain associated with partial-thickness rotator cuff tears.

    PubMed

    Braun, Cordula; Handoll, Helen H

    2018-06-01

    Knowledge about Minimal Important Differences (MIDs) is essential for the interpretation of continuous outcomes, especially patient-reported outcome measures (PROMS). The aim of this study was to estimate the MID for the Western Ontario Rotator Cuff Index (WORC: score 0 (best) to 2100 (worst disability)) in adults with shoulder pain associated with partial-thickness rotator cuff tears, 'symptomatic PTTs', undergoing conservative treatment with physiotherapy. A prospectively-designed anchor-based MID analysis using data from a prospective prognostic study with a three-month follow-up conducted within an outpatient care setting in Germany. The MID was estimated using data from 64 adults with atraumatic symptomatic PTTs who underwent three months of conservative treatment with physiotherapy. The anchor was a seven-point Global Perceived Change (GPC) scale. Based on a definition of the MID being the threshold of "being (at least slightly) improved" with a probability nearest to 0.90 (i.e. 9 of 10 patients achieving the MID), the MID for the WORC was estimated as -300 for 'improved' shoulder-related disability in 9 out of 10 patients (95% CI 8 out of 10 patients to everyone) undergoing three months of exercise-based physiotherapy for symptomatic PTTs. This is the first published MID estimate for the WORC in adults with symptomatic PTTs of the rotator cuff undergoing typical treatment comprising conservative treatment with physiotherapy. The conceptual framework for interpretation facilitates its use in similar clinical contexts. Copyright © 2018. Published by Elsevier Ltd.

  4. Experimental study on the heat transfer characteristics of waste printed circuit boards pyrolysis.

    PubMed

    Ma, Hongting; Du, Na; Lin, Xueyin; Li, Chen; Lai, Junwen; Li, Zihao

    2018-08-15

    In order to study the appropriate and advanced technology for recycling waste printed circuit boards (PCBs), a fixed bed pyrolysis device with stirring function has been designed and developed. The effect of rotating speed on the temperature distribution and mass change in the pyrolysis process of FR-4 PCB has been analyzed. The heat transfer and pyrolysis characteristics of different granular layers with and without stirring have been investigated. The results indicate that the stirring can change the main way of heat transfer from conduction to convection in the PCB layers. As the increase of rotating speed, the temperature rising rate of material at the bottom of the pyrolysis furnace gradually decreases, while the heating rate is increasing at the upper layer, and the temperature difference between the upper and bottom layers is gradually reduced. When the rotating speed varies from 0r/min to 18r/min, the weight loss of the material increases from 3.97% to 6.76%, and the overall pyrolysis degree is improved. During the pyrolysis process, the material layer can be divided into three zones along the vertical direction, namely complete pyrolysis zone, partial pyrolysis zone and non-pyrolysis zone. As the rotating speed is 0r/min, the thickness of each zones is 6cm, 6cm and 3cm, respectively. However, when the rotating speed is increased to 18r/min, the non-pyrolysis zone disappears, and the thickness of complete pyrolysis zone and partial pyrolysis zone increase to 9cm and 6cm, respectively. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. EXERCISE REHABILITATION IN THE NON-OPERATIVE MANAGEMENT OF ROTATOR CUFF TEARS: A REVIEW OF THE LITERATURE

    PubMed Central

    Edwards, Peter; Ebert, Jay; Joss, Brendan; Bhabra, Gev; Ackland, Tim; Wang, Allan

    2016-01-01

    The incidence of rotator cuff tears increases with age, with full-thickness rotator cuff tears present in approximately 25% of individuals in their sixties, and more than 50% of those in their eighties. While surgery is considered an effective treatment, recurrent tears at the insertion site are common, especially with degenerative tears, which are frequent in the older population. More recently, there has been increasing interest in exercise rehabilitation and physical therapy as a means to manage partial and full thickness tears of the rotator cuff by addressing weakness and functional deficits. Recent studies have suggested that patients opting for physical therapy have demonstrated high satisfaction, an improvement in function, and success in avoiding surgery. When considering the increasing rate of shoulder surgery and the associated economic and social burden rotator cuff surgery places on both the patient and the health care system, non-surgical management such as physical therapy and exercise may, in selected cases, be a treatment alternative to surgical repair. The purpose of this clinical commentary is to provide an overview of rotator cuff pathology and pathogenesis, and to present an evidence-based case for the role of conservative rehabilitation in the management of rotator cuff injuries. Level of Evidence Level 5 PMID:27104061

  6. Comparative investigation of five nanoparticles in flow of viscous fluid with Joule heating and slip due to rotating disk

    NASA Astrophysics Data System (ADS)

    Qayyum, Sumaira; Khan, Muhammad Ijaz; Hayat, Tasawar; Alsaedi, Ahmed

    2018-04-01

    Present article addresses the comparative study for flow of five water based nanofluids. Flow in presence of Joule heating is generated by rotating disk with variable thickness. Nanofluids are suspension of Silver (Ag), Copper (Cu), Copper oxide (CuO), Aluminum oxide or Alumina (Al2O3), Titanium oxide or titania (TiO2) and water. Boundary layer approximation is applied to partial differential equations. Using Von Karman transformations the partial differential equations are converted to ordinary differential equations. Convergent series solutions are obtained. Graphical results are presented to examine the behaviors of axial, radial and tangential velocities, temperature, skin friction and Nusselt number. It is observed that radial, axial and tangential velocities decay for slip parameters. Axial velocity decays for larger nanoparticle volume fraction. Effect of nanofluids on velocities dominant than base material. Temperature rises for larger Eckert number and temperature of silver water nanofluid is more because of its higher thermal conductivity. Surface drag force reduces for higher slip parameters. Transfer of heat is more for larger disk thickness index.

  7. Persistent Currents in a Rotating Superleak Partially Filled with Superfluid Helium.

    DTIC Science & Technology

    1982-12-01

    the difference in pressure of the helium bath Po and the reduced vapor pressure in the cell P. In the region from 1.0 to 0.1 the log Po-P has been seen...easily measurable quantities of temperature, T, the helium bath pressure, Po, and the cell pressure P to the film thickness d. Alpha is a measure of the...rotation is controlled by a motor and power supply. The temperature is controlled by the pumping rate and a feedback heater in the helium bath and -maybe

  8. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    PubMed

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P < .001]; Constant total: 87.8 ± 15.3 points [ P < .001]) and remained significantly higher after 10 years (UCLA total: 89.7% ± 15.9% [ P < .001]; Constant total: 77.5 ± 15.6 points [ P < .001]). The Constant total score and Constant strength subscore, but not the UCLA score, were also significantly better at 10 years postoperatively in patients with intact tendons compared with patients with retorn tendons (Constant total: 89.0 ± 7.8 points vs 75.7 ± 14.1 points, respectively [ P = .034]; Constant strength: 18.0 ± 4.9 points vs 9.2 ± 5.2 points, respectively [ P = .006]). The majority of patients rated their satisfaction with the procedure as "excellent" (83.3%), and 87.5% returned to their normal daily activities. Arthroscopic rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  9. Three dimensional rotating flow of Powell-Eyring nanofluid with non-Fourier's heat flux and non-Fick's mass flux theory

    NASA Astrophysics Data System (ADS)

    Ibrahim, Wubshet

    2018-03-01

    This article numerically examines three dimensional boundary layer flow of a rotating Powell-Eyring nanofluid. In modeling heat transfer processes, non-Fourier heat flux theory and for mass transfer non-Fick's mass flux theory are employed. This theory is recently re-initiated and it becomes the active research area to resolves some drawback associated with the famous Fourier heat flux and mass flux theory. The mathematical model of the flow problem is a system of non-linear partial differential equations which are obtained using the boundary layer analysis. The non-linear partial differential equations have been transformed into non-linear high order ordinary differential equations using similarity transformation. Employing bvp4c algorithm from matlab software routine, the numerical solution of the transformed ordinary differential equations is obtained. The governing equations are constrained by parameters such as rotation parameter λ , the non-Newtonian parameter N, dimensionless thermal relaxation and concentration relaxation parameters δt and δc . The impacts of these parameters have been discussed thoroughly and illustrated using graphs and tables. The findings show that thermal relaxation time δt reduces the thermal and concentration boundary layer thickness. Further, the results reveal that the rotational parameter λ has the effect of decreasing the velocity boundary layer thickness in both x and y directions. Further examination pinpoints that the skin friction coefficient along x-axis is an increasing and skin friction coefficient along y-axis is a decreasing function of rotation parameter λ . Furthermore, the non-Newtonian fluid parameter N has the characteristic of reducing the amount of local Nusselt numbers -f″ (0) and -g″ (0) both in x and y -directions.

  10. Incidence of retear with double-row versus single-row rotator cuff repair.

    PubMed

    Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi

    2014-11-01

    Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.

  11. Effort towards symmetric removal and surface smoothening of 1.3-GHz niobium single-cell cavity in vertical electropolishing using a unique cathode

    NASA Astrophysics Data System (ADS)

    Chouhan, Vijay; Kato, Shigeki; Nii, Keisuke; Yamaguchi, Takanori; Sawabe, Motoaki; Hayano, Hitoshi; Ida, Yoshiaki

    2017-08-01

    A detailed study on vertical electropolishing (VEP) of a 1.3-GHz single-cell niobium coupon cavity, which contains six coupons and four viewports at different positions, is reported. The cavity was vertically electropolished using a conventional rod and three types of unique cathodes named as Ninja cathodes, which were designed to have four retractable blades made of either an insulator or a metal or a combination of both. This study reveals the effect of the cathodes and their rotation speed on uniformity in removal thickness and surface morphology at different positions inside the cavity. Removal thickness was measured at several positions of the cavity using an ultrasonic thickness gauge and the surface features of the coupons were examined by an optical microscope and a surface profiler. The Ninja cathode with partial metallic blades was found to be effective not only in reducing asymmetric removal, which is one of the major problems in VEP and might be caused by the accumulation of hydrogen (H2 ) gas bubbles on the top iris of the cavity, but also in yielding a smooth surface of the entire cavity. A higher rotation speed of the Ninja cathode prevents bubble accumulation on the upper iris, and might result in a viscous layer of similar thickness in the cavity cell. Moreover, a higher electric field at the equator owing to the proximity of partial metallic blades to the equator surface resulted in a smooth surface. The effects of H2 gas bubbles and stirring were also observed in lab EP experiments.

  12. Risk Factors for Tear Progression in Symptomatic Rotator Cuff Tears: A Prospective Study of 174 Shoulders.

    PubMed

    Yamamoto, Nobuyuki; Mineta, Mitsuyoshi; Kawakami, Jun; Sano, Hirotaka; Itoi, Eiji

    2017-09-01

    The risk factors for tear progression in symptomatic rotator cuff tears have not been clarified yet. It is important for orthopaedic surgeons to know the natural course of tear progression when nonoperative management is to be chosen. Tears in younger patients, high-activity patients, or heavy laborers would progress in size more than those in older patients, low-activity patients, or light laborers. Case-control study; Level of evidence, 3. Two hundred twenty-five consecutive patients with symptomatic rotator cuff tears visited our institute between 2009 and 2015. Of these, 174 shoulders of 171 patients (mean age, 66.9 years) who underwent at least 2 magnetic resonance imaging (MRI) examinations were prospectively enrolled. The mean follow-up was 19 months. Tear progression was defined as positive when the tear size increased by ≥2 mm. The demographic factors that were analyzed by multivariate analysis included age, sex, hand dominance, smoking, alcohol drinking, hypercholesterolemia, sports participation, job type, tear size, and tear type (full or partial thickness). Of the 174 shoulders, 82 shoulders (47%) showed tear progression. The mean (±SD) tear length and width in the progression group on final MRI were 23.1 ± 12.5 mm and 17.3 ± 9.6 mm, respectively; the tear size progressed by a mean 5.8 ± 5.6 mm in length and 3.1 ± 5.2 mm in width. The mean propagation speed was 3.8 mm/y in length and 2.0 mm/y in width. The size of full-thickness tears significantly increased compared with that of articular-sided partial-thickness tears ( P = .0215). The size of medium tears significantly increased compared with that of other tears ( P < .0001). According to the logistic regression analysis, smoking was significantly correlated with tear progression ( P = .026). Subgroup analyses showed that male sex, hand dominance, and trauma were correlated with tear progression. Age, alcohol drinking, hypercholesterolemia, sports participation, and job type did not show any correlation with tear progression. The tear size of symptomatic rotator cuff tears progressed in 47% of the shoulders during a mean of 19 months, and the speed of progression was 3.8 mm/y in length and 2.0 mm/y in width. The risk factors for tear progression were (1) a medium-sized tear, (2) a full-thickness tear, and (3) smoking.

  13. Clast Rotation and Nature of Strain Localization in Thick Ultramylonites: the El Pichao Shear Zone (Sierra de Quilmes), NW Argentina.

    NASA Astrophysics Data System (ADS)

    Hasalova, Pavlina; Hunter, Nicholas James; Weinberg, Roberto; Finch, Melanie

    2013-04-01

    Ultramylonite formation is integral to understanding the accommodation of high strain in ductile shear zones, mountain building and crustal movement. The El Pichao Shear Zone (PSZ) is 3-7km thick ductile thrust zone in the Sierra de Quilmes, NW Argentina. Sinistral thrusting along the PSZ has placed granulite facies migmatites of the Tolombón Complex on top of amphibolite metasedimentary rocks of the Agua del Sapo Complex, separated by a sheared granitic body intruded by pegmatites. The fabric varies from protomylonite to ultramylonite. Ultramylonites in the core of the shear zone reach ~1km in thickness. Ultramylonites of this thickness are extremely rare, and thus the El Pichao Shear Zone provides a unique opportunity to investigate the origin of such high strain rocks. We used microstructural and quantitative textural analysis, quartz crystallographic preferred orientation (CPO), clast vorticity and geochemical data to investigate the origin of the thick ultramylonites, and variable strain accommodation associated with the mylonitization process. The mylonitic rocks have granitic composition and consist of a matrix of Bt+Qtz+Ms+Pl+Kfs, Qtz ribbons, mica bands and feldspar porphyroclasts. Feldspar clasts have been variably rotated and their deformation behaviour varies between brittle faulting and partial to complete dynamic recrystallisation. In the ultramylonite Qtz ribbons or strong S-C fabrics are lacking and the matrix tends to be homogeneous with only weak foliation defined by the preferred orientation of micas. There is also a systematic decrease in matrix grain size and mica connectivity towards ultramylonite. Quartz CPO suggests changes in deformation mechanisms associated with strain increase. The transition between mylonite and ultramylonite in the PSZ occurred due to a switch from dominant dislocation creep to dominant diffusion creep. Major and trace element data show no geochemical variation between samples, indicating that the mylonite-ultramylonite transition took place in a closed system with fixed P-T conditions. We argue that the formation of thick ultramlyonites can occur where strain is high enough to instigate intense clast rotation. The homogenization of the originally banded mylonite results from continual rotation of clasts, which disaggregated the anisotropic matrix and thus inhibited strain localisation. The relative rotation of clasts in the matrix was a function of their vorticity and geometry, which may have influenced the variable deformation behaviours of feldspars in the mylonites. Strain softening at the clast matrix interface may have also played a role in increasing the vorticity of clasts and promoting rotation-induced strain accomodation. Ultramylonite thickness may be explained, at least in part, by the homogenisation of the matrix by clast rotation, where the loss of effective slip planes resulted in strain being dispersed over larger areas in the ultramylonite.

  14. Functional Outcomes and Predictors of Failure After Rotator Cuff Repair During Total Shoulder Arthroplasty.

    PubMed

    Livesey, Michael; Horneff, John G; Sholder, Daniel; Lazarus, Mark; Williams, Gerald; Namdari, Surena

    2018-05-01

    A well-functioning rotator cuff is necessary for successful anatomic total shoulder arthroplasty (TSA). This study evaluated patients who underwent concomitant TSA and rotator cuff repair (RCR) for functional outcomes, revision rates, and predictors of poor results. Retrospective chart review was conducted to identify patients who underwent TSA and RCR. Demographic data, rotator cuff tear and RCR characteristics, range of motion, and radiographs were recorded. Minimum 2-year functional outcomes were obtained. Predictors of reoperation and/or poor clinical results were determined. Forty-five patients met inclusion criteria (22 high-grade partial-thickness and 23 full-thickness tears). Fourteen (31%) patients were labeled as having a poor result; 8 (18%) patients required reoperation. There was a significant difference between the acromiohumeral interval preoperatively and immediately postoperatively (P=.013). However, at maximum radiographic follow-up, the acromiohumeral interval was not significantly different from preoperative values (P=.86). Patients with a preoperative acromiohumeral interval of less than 8 mm had an increased rate of cuff-related reoperation (P=.003). Although concomitant TSA and RCR is a reasonable consideration, 31% of patients had a poor clinical result. An acromiohumeral interval of less than 8 mm was a predictor of cuff-related reoperation and may be an indication to consider reverse arthroplasty in the setting of joint arthrosis with a rotator cuff tear. [Orthopedics. 2018; 41(3):e334-e339.]. Copyright 2018, SLACK Incorporated.

  15. The role of platelet-rich plasma in rotator cuff repair.

    PubMed

    Mei-Dan, Omer; Carmont, Michael R

    2011-09-01

    The shoulder is a common source of disability resulting from traumatic and degenerate tears of the rotator cuff, subacromial impingement, and osteoarthritis. Nonoperative management has focused on treatment of the predisposing factors, the use of analgesics and anti-inflammatory medication usually in association with local anesthetic and steroid injections. Surgical intervention allows debridement of the degenerate cuff and partial thickness cuff tears, subacromial bursitis, impinging bone spurs and osteophytes together with rotator cuff repairs. Repairs of degenerate and torn tissue are often prone to failure due to many intrinsic and extrinsic factors. It is assumed that some biological therapies might improve clinical, mechanical, and histologic outcomes. Injections of platelet-rich plasma (PRP) have led to reduced pain and improved recovery in other degenerate pathologies areas together with the restoration of function. This study reviews the current literature on PRP and in particular discusses its relevance in the treatment of rotator cuff tears.

  16. The Repaired Rotator Cuff: MRI and Ultrasound Evaluation.

    PubMed

    Lee, Susan C; Williams, Danielle; Endo, Yoshimi

    2018-03-01

    The purposes of this review were to provide an overview of the current practice of evaluating the postoperative rotator cuff on imaging and to review the salient imaging findings of the normal and abnormal postoperative rotator cuff, as well as of postoperative complications. The repaired rotator cuff frequently appears abnormal on magnetic resonance imaging (MRI) and ultrasound (US). Recent studies have shown that while the tendons typically normalize, they can demonstrate clinically insignificant abnormal imaging appearances for longer than 6 months. Features of capsular thickening or subacromial-subdeltoid bursal thickening and fluid distension were found to decrease substantially in the first 6-month postoperative period. MRI and US were found to be highly comparable in the postoperative assessment of the rotator cuff, although they had a lower sensitivity for partial thickness tears. Imaging evaluation of newer techniques such as patch augmentation and superior capsular reconstruction needs to be further investigated. MRI and US are useful in the postoperative assessment of the rotator cuff, not only for evaluation of the integrity of the rotator cuff, but also for detecting hardware complications and other etiologies of shoulder pain.

  17. MRI findings associated with luxatio erecta humeri.

    PubMed

    Krug, David K; Vinson, Emily N; Helms, Clyde A

    2010-01-01

    Luxatio erecta humeri is a rare type of inferior glenohumeral dislocation with a unique radiographic appearance; however, the magnetic resonance imaging findings associated with this dislocation have not been described in the radiology literature. The purpose of this study is to identify magnetic resonance imaging findings associated with this uncommon type of glenohumeral dislocation. The magnetic resonance imaging features of four patients with clinical and radiographic evidence of luxatio erecta humeri were reviewed retrospectively by two musculoskeletal-trained radiologists. The reported mechanism of injury in all four patients was falling. The MR imaging examinations were evaluated for the presence of rotator cuff and biceps tendon pathology, glenoid labrum pathology, joint capsule and glenohumeral ligament injury, fractures and bone marrow contusions, articular cartilage injury, and joint effusions. All four patients demonstrated pathology of the glenohumeral joint. Three of the four patients demonstrated rotator cuff tears, including large full thickness tears of the supraspinatus and infraspinatus tendons in two patients, and small full thickness tear of the supraspinatus tendon with partial thickness tear of the infraspinatus tendon in the third patient. In the two patients with large full thickness tears of the supraspinatus and infraspinatus tendons, one patient demonstrated tearing of the subscapularis tendon with dislocation of a partially torn long head of the biceps tendon, and the second patient demonstrated full thickness tearing of the intra-articular biceps tendon. All four patients demonstrated injuries to the glenoid labrum and both anterior and posterior bands of the inferior glenohumeral ligament. Contusions or fractures of the humeral head were seen in two of the patients. Three of the four patients demonstrated cartilage abnormalities including a focal cartilage defect in the anterior inferior glenoid in one patient, and cartilage surface irregularity of the glenoid in the other two patients. Common magnetic resonance imaging findings in patients with a prior luxatio erecta humeri dislocation include rotator cuff tears, injury to the glenoid labrum, and injury to both the anterior and posterior bands of the inferior glenohumeral ligament. These findings are compatible with the mechanism of dislocation in luxatio erecta, and noting these findings on magnetic resonance imaging may suggest that the patient has sustained a prior inferiorly directed glenohumeral dislocation such as luxatio erecta.

  18. Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears.

    PubMed

    Zhang, Chun-Gang; Zhao, De-Wei; Wang, Wei-Ming; Ren, Ming-Fa; Li, Rui-Xin; Yang, Sheng; Liu, Yu-Peng

    2010-11-01

    For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of ≤ 45° into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Gap formation for the transtendon single-row repair was significantly smaller (P < 0.05) when compared with the double-row repair for the first cycle ((1.74 ± 0.38) mm vs. (2.86 ± 0.46) mm, respectively) and the last cycle ((3.77 ± 0.45) mm vs. (5.89 ± 0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P < 0.05) when compared with the double-row repair. Also, it had a higher mean ultimate tensile load and stiffness. For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation.

  19. Magnetic resonance anatomy of the superior part of the rotator cuff in normal shoulders, assessment and practical implication.

    PubMed

    Michelin, Paul; Trintignac, Adrien; Dacher, Jean Nicolas; Carvalhana, Gilbert; Lefebvre, Valentin; Duparc, Fabrice

    2014-12-01

    The superior part of the rotator cuff consists of the anterior (SSa) and posterior (SSp) parts of the supraspinatus tendon, the infraspinatus (IS) tendon plus the articular capsule. An overlap of the distal SSp tendon by the anterior part of the IS one has been anatomically demonstrated; the insertion area of the IS is more anterior than currently believed. The aim of our study was to assess this complex architecture through standard MRI scans. Twenty-five healthy volunteers underwent a shoulder MRI. Three planes T2 fat saturation sequences were read in consensus by two radiologists. The SSa, the SSp, the IS tendons and the articular capsule were assessed for visibility. The patterns of demarcation of each structure from adjacent ones were assessed. The width and the thickness of each tendinous band were measured on sagittal images. The SSa, the SSp and the IS tendons were distinguishable in all patients. The anterior part of the IS tendon overlapped the SSp tendon to reach a quite anterior insertion into the greater tuberosity of the humerus. The SSa, the SSp and the IS tendons were 6.5-3.4, 15.1-2.8 and 26.8-2.2 mm wide and thick, respectively. MR images of the normal superior rotator cuff are consistent with latest anatomical descriptions. The distal superposition of the IS over the SSp tendon should be considered regarding the linear increased signal areas and the commonly named "partial thickness ruptures" of the superior rotator cuff as well as the fatty infiltration of the IS muscle.

  20. Real-time compound sonography of the rotator-cuff: evaluation of artefact reduction and image definition.

    PubMed

    De Candia, Alessandro; Doratiotto, Stefsano; Paschina, Elio; Segatto, Enrica; Pelizzo, Francesco; Bazzocchi, Massimo

    2003-04-01

    The aim of this study was to compare real time compound sonography with conventional sonography in the evaluation of rotator cuff tears. A prospective study was performed on 50 supraspinatus tendons in 101 patients treated by surgical acromioplasty. The surgeon described 33 (66%) full-thickness tears and 17 (34%) partial-thickness tears. All tendons were examined by conventional sonography and real time compound sonography on the day before surgery. The techniques were compared by evaluating the images for freedom from artefacts, contrast resolution and overall image definition. Real time compound sonography proved to be superior to conventional sonography as regards freedom from artefacts in 50 cases out of 50 (100%). It was superior to conventional sonography in evaluating the image contrast resolution in 45 cases out of 50 (90%), and superior to conventional sonography in overall image definition in 45 out of 50 cases (90%). Real-time compound sonography reduces the intrinsic artefacts of conventional sonography and allows better overall image definition. In particular, the digital technique allowed us to study the rotator cuff with better contrast resolution and sharper and more detailed images than did conventional sonography.

  1. Method for hot pressing irregularly shaped refractory articles

    DOEpatents

    Steinkamp, William E.; Ballard, Ambrose H.

    1982-01-01

    The present invention is directed to a method for hot pressing irregularly haped refractory articles with these articles of varying thickness being provided with high uniform density and dimensional accuracy. Two partially pressed compacts of the refractory material are placed in a die cavity between displaceable die punches having compact-contacting surfaces of the desired article configuration. A floating, rotatable block is disposed between the compacts. The displacement of the die punches towards one another causes the block to rotate about an axis normal to the direction of movement of the die punches to uniformly distribute the pressure loading upon the compacts for maintaining substantially equal volume displacement of the powder material during the hot pressing operation.

  2. Impact of a counter-rotating planetary rotation system on thin-film thickness and uniformity

    DOE PAGES

    Oliver, J. B.

    2017-06-12

    Planetary rotation systems incorporating forward- and counter-rotating planets are used as a means of increasing coating-system capacity for large oblong substrates. Comparisons of planetary motion for the two types of rotating systems are presented based on point tracking for multiple revolutions, as well as comparisons of quantitative thickness and uniformity. Counter-rotation system geometry is shown to result in differences in thin-film thickness relative to standard planetary rotation for precision optical coatings. As a result, this systematic error in thin-film thickness will reduce deposition yields for sensitive coating designs.

  3. Impact of a counter-rotating planetary rotation system on thin-film thickness and uniformity.

    PubMed

    Oliver, J B

    2017-06-20

    Planetary rotation systems incorporating forward- and counter-rotating planets are used as a means of increasing coating-system capacity for large oblong substrates. Comparisons of planetary motion for the two types of rotating systems are presented based on point tracking for multiple revolutions as well as comparisons of quantitative thickness and uniformity. Counter-rotation system geometry is shown to result in differences in thin-film thickness relative to standard planetary rotation for precision optical coatings. This systematic error in thin-film thickness will reduce deposition yields for sensitive coating designs.

  4. Impact of a counter-rotating planetary rotation system on thin-film thickness and uniformity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliver, J. B.

    Planetary rotation systems incorporating forward- and counter-rotating planets are used as a means of increasing coating-system capacity for large oblong substrates. Comparisons of planetary motion for the two types of rotating systems are presented based on point tracking for multiple revolutions, as well as comparisons of quantitative thickness and uniformity. Counter-rotation system geometry is shown to result in differences in thin-film thickness relative to standard planetary rotation for precision optical coatings. As a result, this systematic error in thin-film thickness will reduce deposition yields for sensitive coating designs.

  5. Clinical Outcomes of Conservative Treatment and Arthroscopic Repair of Rotator Cuff Tears: A Retrospective Observational Study.

    PubMed

    Lee, Woo Hyung; Do, Hyun Kyung; Lee, Joong Hoon; Kim, Bo Ram; Noh, Jee Hyun; Choi, Soo Hyun; Chung, Sun Gun; Lee, Shi-Uk; Choi, Ji Eun; Kim, Seihee; Kim, Min Jee; Lim, Jae-Young

    2016-04-01

    To compare the clinical outcomes following conservative treatment and arthroscopic repair in patients with a rotator cuff tear. In this retrospective study, patients aged >50 years with a symptomatic rotator cuff tear were reviewed. The rotator cuff tendons were evaluated using ultrasonography, shoulder magnetic resonance imaging or MR arthrography, and the patients with either a high-grade partial-thickness or small-to-medium-sized (≤3 cm) full-thickness tear were included in this study. The primary outcome measures were a pain assessment score and range of motion (ROM) at 1-year follow-up. The secondary outcomes were the rate of tear progression or retear along with the rate of symptom aggravation after the treatments. A total of 357 patients were enrolled, including 183 patients that received conservative treatment and 174 patients who received an arthroscopic repair. The pain assessment score (p<0.001) and the ROM in forward flexion (p<0.001) were significantly improved in both groups. The ROM in internal rotation did not significantly change after conservative treatment and arthroscopic repair. The pain assessment score and ROM were not significantly different between the two groups. Retear was observed in 9.6% of patients who had an arthroscopic repair and tear progression was found in 6.7% of those who underwent conservative treatment. The proportion of aggravation for pain and ROM did not significantly differ between the two groups. The effectiveness of conservative treatment is not inferior to arthroscopic repair for patients >50 years old with a less than medium-sized rotator cuff tear in a 1-year follow-up period. Further study is warranted to find the optimal combination of conservative treatment for a symptomatic rotator cuff tear.

  6. Comparison of 2- and 3-dimensional shoulder ultrasound to magnetic resonance imaging in a community hospital for the detection of supraspinatus rotator cuff tears with improved worktime room efficiency.

    PubMed

    Co, Steven; Bhalla, Sonny; Rowan, Kevin; Aippersbach, Sven; Bicknell, Simon

    2012-08-01

    The purpose of this study was to evaluate whether 3-dimensional (3D) volumetric acquisition of shoulder ultrasound (US) data for supraspinatus rotator cuff tears is as sensitive when compared with conventional 2-dimensional (2D) US and routine magnetic resonance imaging (MRI), and whether there is improved workroom time efficiency when using the 3D technique compared with the 2D technique. In this prospective study, 39 shoulders underwent US and MRI examination of their rotator cuff to confirm the accuracy of both the 2D and 3D techniques. The difference in sensitivities was compared by using confidence interval analysis. The mean times required to obtain the 2D and 3D US data and to review the scans were compared by using a 1-tailed Wilcoxon test. Sensitivity and specificity of 2D US in detecting supraspinatus full- and partial-thickness tears was 100% and 96%, and 80% and 100%, respectively, and similar values were obtained with 3D US at 100% and 100%, and 90% and 96.6%, respectively. Analysis of the confidence limits of the sensitivities showed no significant difference. The mean time (± SD) of the overall 2D examination of the shoulder, including interpretation was 10.02 ± 3.28 minutes, whereas, for the 3D examination, it was 7.08 ± 0.35 minutes. Comparison between the 2 cohorts when using a 1-tailed Wilcoxon test showed a statistically significant difference (P < .05). 3D US of the shoulder is as accurate as 2D US when compared with MRI for the diagnosis of full- and partial-thickness supraspinatus rotator cuff tears, and 3D US examination significantly reduced the time between the initial scan and the radiologist interpretation, ultimately improving workplace efficiency. Copyright © 2012 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  7. Characterization of SiGe thin films using a laboratory X-ray instrument

    PubMed Central

    Ulyanenkova, Tatjana; Myronov, Maksym; Benediktovitch, Andrei; Mikhalychev, Alexander; Halpin, John; Ulyanenkov, Alex

    2013-01-01

    The technique of reciprocal space mapping using X-rays is a recognized tool for the nondestructive characterization of epitaxial films. X-ray scattering from epitaxial Si0.4Ge0.6 films on Si(100) substrates using a laboratory X-ray source was investigated. It is shown that a laboratory source with a rotating anode makes it possible to investigate the material parameters of the super-thin 2–6 nm layers. For another set of partially relaxed layers, 50–200 nm thick, it is shown that from a high-resolution reciprocal space map, conditioned from diffuse scattering on dislocations, it is possible to determine quantitatively from the shape of a diffraction peak (possessing no thickness fringes) additional parameters such as misfit dislocation density and layer thickness as well as concentration and relaxation. PMID:24046495

  8. Characterization of SiGe thin films using a laboratory X-ray instrument.

    PubMed

    Ulyanenkova, Tatjana; Myronov, Maksym; Benediktovitch, Andrei; Mikhalychev, Alexander; Halpin, John; Ulyanenkov, Alex

    2013-08-01

    The technique of reciprocal space mapping using X-rays is a recognized tool for the nondestructive characterization of epitaxial films. X-ray scattering from epitaxial Si 0.4 Ge 0.6 films on Si(100) substrates using a laboratory X-ray source was investigated. It is shown that a laboratory source with a rotating anode makes it possible to investigate the material parameters of the super-thin 2-6 nm layers. For another set of partially relaxed layers, 50-200 nm thick, it is shown that from a high-resolution reciprocal space map, conditioned from diffuse scattering on dislocations, it is possible to determine quantitatively from the shape of a diffraction peak (possessing no thickness fringes) additional parameters such as misfit dislocation density and layer thickness as well as concentration and relaxation.

  9. On the time-variable nature of Titan's obliquity

    NASA Astrophysics Data System (ADS)

    Noyelles, Benoit; Nimmo, Francis

    2014-05-01

    Titan presents an unexpectedly high obliquity (Stiles et al. 2008, Meriggiola & Iess 2012) while its topography and gravity suggest a non-hydrostatic ice shell (Hemingway et al. 2013). We here present a 6-dof model of the rotation of Titan simultaneously simulating the full orientation of the shell and the inner core, and considering a global subsurface ocean with a partially-compensated shell of spatially-variable thickness. Between 10 and 13% of our realistic interior models induce a resonance with the annual forcing, that dramatically raises the obliquity. The relevant model Titans are composed of a 130-140 km thick shell floating on a ~250 km thick ocean. The observed obliquity should not be considered as a mean one but as an instantaneous one, that should vary by ~7 arcmin over the duration of the Cassini mission.

  10. Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis.

    PubMed

    McGarvey, Ciaran; Harb, Ziad; Smith, Christian; Houghton, Russell; Corbett, Steven; Ajuied, Adil

    2016-02-01

    To compare the diagnostic accuracy of magnetic resonance imaging (MRI), 2-dimensional magnetic resonance arthrogram (MRA) and 3-dimensional isotropic MRA in the diagnosis of rotator cuff tears when performed exclusively at 3-T. A systematic review was undertaken of the Cochrane, MEDLINE and PubMed databases in accordance with the PRISMA guidelines. Studies comparing 3-T MRI or 3-T MRA (index tests) to arthroscopic surgical findings (reference test) were included. Methodological appraisal was performed using QUADAS 2. Pooled sensitivity and specificity were calculated and summary receiver-operating curves generated. Kappa coefficients quantified inter-observer reliability. Fourteen studies comprising 1332 patients were identified for inclusion. Twelve studies were retrospective and there were concerns regarding index test bias and applicability in nine and six studies respectively. Reference test bias was a concern in all studies. Both 3-T MRI and 3-T MRA showed similar excellent diagnostic accuracy for full-thickness supraspinatus tears. Concerning partial-thickness supraspinatus tears, 3-T 2D MRA was significantly more sensitive (86.6 vs. 80.5 %, p = 0.014) but significantly less specific (95.2 vs. 100 %, p < 0.001). There was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA showed similar accuracy to 3-T conventional 2D MRA. Three-Tesla MRI appeared equivalent to 3-T MRA in the diagnosis of full- and partial-thickness tears, although there was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA appears equivalent to 3-T 2D MRA for all types of tears.

  11. Outcome Comparison Between in Situ Repair Versus Tear Completion Repair for Partial Thickness Rotator Cuff Tears.

    PubMed

    Kim, Yang-Soo; Lee, Hyo-Jin; Bae, Sung-Ho; Jin, Hyonki; Song, Hyun Seok

    2015-11-01

    To compare the clinical outcomes of arthroscopic in situ repair with the tear completion repair technique for partial-thickness rotator cuff tears (PT-RCTs). We prospectively enrolled 100 cases with articular-sided and bursal-sided PT-RCTs exceeding 50% of tendon thickness and allocated them randomly. An in situ repair was performed in group 1 (n = 50). Completion of the remaining cuff tissue and repair were performed in group 2 (n = 50). The medial row was knotted as transosseous repair (suture-bridge technique) in all cases. American Shoulder Elbow Society (ASES) score, Constant shoulder (CS) score, Simple shoulder (SS) score, and Korean shoulder (KS) score, and visual analog scale (VAS) for pain and range of motion were assessed at 3, 6, and 12 months and at the last visit. Repaired tendon integrity was determined at 6 to 12 months by magnetic resonance imaging. Eight cases were lost to follow-up. Ultimately, 92 cases were analyzed. The average follow-up was 19.1 months (range, 12 to 42 months). Significant improvements in the VAS for pain and functional outcomes were observed in both groups postoperatively (P = .001 for VAS; P < .001 for ASES score; P < .001 for CS score; P = .001 for SS score; P<.001 for KS score). No significant difference in the clinical results was observed at any time between the groups. No difference of retear rate on articular-sided PT-RCT was observed between the groups (P = .34). Retears on the bursal-sided PT-RCT were more frequent in group 2 (P = .02). Arthroscopic repair of PT-RCT exceeding 50% of the thickness provided functional improvements and pain relief regardless of the repair technique. The retear rate for bursal-sided PT-RCT was higher in group 2, although the retear rate for the articular-sided PT-RCT was not different. Level II, prospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Comparative outcomes of extracorporeal shockwave therapy for shoulder tendinitis or partial tears of the rotator cuff in athletes and non-athletes: Retrospective study.

    PubMed

    Chou, Wen-Yi; Wang, Ching-Jen; Wu, Kuan-Ting; Yang, Ya-Ju; Cheng, Jai-Hong; Wang, Shih-Wei

    2018-03-01

    Refractory shoulder tendinitis or partial thickness rotator cuff tears (PTRCTs) are common findings in overhead athletes. Previous studies have examined the effectiveness of extracorporeal shockwave therapy (ESWT) for shoulder tendinitis. In the current study, we recruited 36 shoulders and performed a comparison between the professional athletes (13 shoulders, athletic group; AG) and the non-athletic population (23 shoulders, non-athletic group, NAG) with PTRCTs or shoulder tendinitis of the shoulder after ESWT. Patients with symptomatic tendinitis of the shoulder with or without a partial tear of the rotator cuff tendon and failed oral medication and physical therapy for more than 3 months were treated with electrohydraulic mode of ESWT. All patients that met the inclusion criteria were categorized into two groups according to their pre-treatment activity level. We found that NAG exhibited significant aging and degenerative change around the glenohumeral joint and subacromial space. After ESWT treatment, the patients in AG were with 53.8% high satisfaction rating and patients in NAG were 52.1% by one-year followed up. The results showed ESWT was equally effective treatment in both AG and NAG. In light of its efficacy and less-invasive nature, we suggest ESWT can be used to treat athletes with refractory tendinitis or PTRCTs before proceeding to arthroscopic intervention. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Beam hardening and partial beam hardening of the bowtie filter: Effects on dosimetric applications in CT

    NASA Astrophysics Data System (ADS)

    Lopez-Rendon, X.; Zhang, G.; Bosmans, H.; Oyen, R.; Zanca, F.

    2014-03-01

    Purpose: To estimate the consequences on dosimetric applications when a CT bowtie filter is modeled by means of full beam hardening versus partial beam hardening. Method: A model of source and filtration for a CT scanner as developed by Turner et. al. [1] was implemented. Specific exposures were measured with the stationary CT X-ray tube in order to assess the equivalent thickness of Al of the bowtie filter as a function of the fan angle. Using these thicknesses, the primary beam attenuation factors were calculated from the energy dependent photon mass attenuation coefficients and used to include beam hardening in the spectrum. This was compared to a potentially less computationally intensive approach, which accounts only partially for beam hardening, by giving the photon spectrum a global (energy independent) fan angle specific weighting factor. Percentage differences between the two methods were quantified by calculating the dose in air after passing several water equivalent thicknesses representative for patients having different BMI. Specifically, the maximum water equivalent thickness of the lateral and anterior-posterior dimension and of the corresponding (half) effective diameter were assessed. Results: The largest percentage differences were found for the thickest part of the bowtie filter and they increased with patient size. For a normal size patient they ranged from 5.5% at half effective diameter to 16.1% for the lateral dimension; for the most obese patient they ranged from 7.7% to 19.3%, respectively. For a complete simulation of one rotation of the x-ray tube, the proposed method was 12% faster than the complete simulation of the bowtie filter. Conclusion: The need for simulating the beam hardening of the bow tie filter in Monte Carlo platforms for CT dosimetry will depend on the required accuracy.

  14. From platelet-rich plasma to the reverse prosthesis: controversies in treating rotator cuff pathology.

    PubMed

    Craig, Edward V; Galatz, Leesa M; Sperling, John W

    2014-01-01

    Rotator cuff pathology and tearing remains a common cause of shoulder pain and disability. Although little controversy and disagreement exists regarding the treatment of small to moderate size tears in good quality tissue without retraction, there is difficulty in agreeing on the ideal treatment of the largest tears, particularly because those tears may be accompanied by widely variable levels of pain and function. Clinical decision making is made more difficult because of the variable presentations observed in patients with a documented full-thickness rotator cuff tear: some have good function and no pain, some have good function and pain, some have poor function and no pain, and some have both poor function and pain. The role of biologics as an adjunct in treating most rotator cuff tears remains unclear, with ongoing exploration of the roles of stem cells, growth factors, and platelet-rich plasma. In patients with unreconstructable tears with marked weakness in external rotation but good elevation, a latissimus transfer may restore rotation. Patches may play a role in partial repairs while serving as both a lattice for healing and a biomechanical anchoring point for sutures. In patients with massive tears and arthritis and in many who have rotator cuff insufficiency, pseudoparalysis, or anterosuperior escape without arthritis, reverse shoulder arthroplasty has led to improvements in pain and strength and revolutionized the treatment of rotator cuff tears.

  15. Hyperlipidemia increases the risk of retear after arthroscopic rotator cuff repair.

    PubMed

    Garcia, Grant H; Liu, Joseph N; Wong, Alexandra; Cordasco, Frank; Dines, David M; Dines, Joshua S; Gulotta, Lawrence V; Warren, Russell

    2017-12-01

    Hyperlipidemia (HL) has been identified as a risk factor for rotator cuff tear, but no studies have evaluated its effects on healing. The purpose of this study was to evaluate the effect of HL and statin use on rotator cuff healing after arthroscopic repair. This was a retrospective review of 85 patients (86 shoulders) who underwent arthroscopic rotator cuff repair with postoperative ultrasound evaluation. Ultrasound findings were graded no retear, partial-thickness retear (PT), or full-thickness retear (FT). Average age was 62.1 years (45.3-74.3 years). On ultrasound evaluation, 65 shoulders (75.5%) had no retear, 14 (16.3%) had PT, and 7 (8.1%) had FT. There was no significant difference in retear rate by age, technique, or tissue quality. There were 33 patients (38.8%) who had the diagnosis of HL, and all were taking a statin medication. Compared with patients without HL, patients with HL had significantly higher rates of FT (18.1% vs. 1.9%; P < .001) and PT (27.2% vs. 9.4%; P < .001). The total retear rate (PT and FT) for HL patients was significantly higher at 45.5% (15/33) compared with the patients without HL at 11.3% (6/53), with an odds ratio of 6.5 (P < .001). There was no difference in retear rate by dosage or type of statin mediation. After arthroscopic rotator cuff repair, HL was a risk factor for retear. Further investigation is warranted on this topic, and these results may help in managing expectations after surgery. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Outcomes of Arthroscopic Rotator Cuff Repair in Patients Who Are 70 Years of Age or Older Versus Under 70 Years of Age: A Sex- and Tear Size-Matched Case-Control Study.

    PubMed

    Gwark, Ji-Yong; Sung, Chang-Meen; Na, Jae-Boem; Park, Hyung Bin

    2018-05-19

    To compare the structural and clinical outcomes after arthroscopic rotator cuff repair (ARCR) of a case group aged 70 and above with those of a control group younger than 70, with the 2 groups matched for sex and tear size. The case group, comprising 53 patients 70 or older, and the control group, comprising 159 patients younger than 70, all received ARCR to 1 shoulder with symptomatic full-thickness rotator cuff tear. The case and the control subjects, who were matched for sex and tear size to minimize bias related to tendon healing, received ARCR during the same period. The mean age was 71.8 ± 2.6 years in the case group and 59.3 ± 7.1 years in the control group. The minimum follow-up period was 1 year in both groups. Cuff integrity was evaluated using ultrasonography. Structural and clinical outcomes of the 2 groups were compared. Regarding structural outcomes, the complete healing, partial-thickness retear, and full-thickness retear rates were 66% (35/53), 15% (8/53), and 19% (10/53) in the case group, and 68% (108/159), 19% (30/159), and 13% (21/159), respectively, in the control group. The 2 groups had no significantly different retear rates (P = .52). Regarding clinical outcomes, the mean improvements in range of motion, pain, muscle strength, and age- and sex-matched Constant scores were not significantly different between the 2 groups (P > .37). The preoperative tear size was significantly associated with retear in both studied groups (P = .02). The clinical and structural outcomes of ARCR in patients 70 or older with symptomatic full-thickness rotator cuff tear are comparable with those in patients younger than 70 with at least 1-year follow-up. Preoperative tear size, a biological factor, is a strong predictor for retear. Level III, a retrospective comparative (case-control) study. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Not all ultrasounds are created equal: general sonography versus musculoskeletal sonography in the detection of rotator cuff tears

    PubMed Central

    Cole, Brandi; Twibill, Kristen; Lam, Patrick; Hackett, Lisa

    2016-01-01

    Background This cross-sectional analytic diagnostic accuracy study was designed to compare the accuracy of ultrasound performed by general sonographers in local radiology practices with ultrasound performed by an experienced musculoskeletal sonographer for the detection of rotator cuff tears. Methods In total, 238 patients undergoing arthroscopy who had previously had an ultrasound performed by both a general sonographer and a specialist musculoskeletal sonographer made up the study cohort. Accuracy of diagnosis was compared with the findings at arthroscopy. Results When analyzed as all tears versus no tears, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 95%, whereas general sonography had an accuracy of 91%, a sensitivity of 91% and a specificity of 86%. When the partial tears were split with those ≥ 50% thickness in the tear group and those < 50% thickness in the no-tear group, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 100% and general sonography had an accuracy of 85%, a sensitivity of 84% and a specificity of 87%. Conclusions Ultrasound in the hands of an experienced musculoskeletal sonographer is highly accurate for the diagnosis of rotator cuff tears. General sonography has improved subsequent to earlier studies but remains inferior to an ultrasound performed by a musculoskeletal sonographer. PMID:27660657

  18. The gymnast's shoulder MRI and clinical findings.

    PubMed

    De Carli, A; Mossa, L; Larciprete, M; Ferretti, M; Argento, G; Ferretti, A

    2012-02-01

    The aim of the study was to evaluate effects of shoulder overuse in elite symptomatic or asymptomatic gymnasts. This was a university-based sport traumatology research, a cohort study, with a control group comparison. Patients included were: 21 elite male gymnasts performing in the Italian National team for at least 10 years and a control group of 10 patients (20 shoulders) of the same age and sex, randomly selected among a healthy non-athletic population who underwent shoulder MRI. Magnetic resonance imaging without contrast were performed to all participants and clinical findings were summarized. Two experienced musculoskeletal radiologists interpreted each MRI scan for multiple variables (rotator cuff tendons, labral signal, capsule), including type of measurements performed on soft tissues (muscles, tendons) to assess global modifications of the shoulders. Signal abnormalities were detected in 36/36 (100%) gymnasts' shoulders, and in 4/20 (20%) of the controls. Sixteen of 36 (44.4%) shoulders had findings consistent with SLAP tears, bilateral in four patients; anteroinferior labrum lesions were identified in 10/36 (27.7%) shoulders, as compared with none (0%) in the controls. Eight of 36 (22%) shoulders had findings consistent with partial- or full-thickness tears of the rotator cuff as compared with none (0%) of the controls. Increased thickness of rotator cuff tendons and hypertrophy of rotator cuff muscles and deltoid muscles were recorded: such reports were symmetrical between dominant and non dominant arms, and increased when compared to controls. Gymnasts' shoulders are significantly different from those of the general population. MRI findings, especially SLAP tears, and hypertrophy are symmetrical. SLAP tears seem to be responsible of most early retirement.

  19. Magneto-Rayleigh-Taylor instability driven by a rotating magnetic field

    NASA Astrophysics Data System (ADS)

    Duan, Shuchao; Xie, Weiping; Cao, Jintao; Li, Ding

    2018-04-01

    In this paper, we analyze theoretically the magneto-Rayleigh-Taylor instability driven by a rotating magnetic field. Slab configurations of finite thickness are treated both with and without using the Wenzel-Kramers-Brillouin approximation. Regardless of the slab thickness, the directional rotation of the driving magnetic field contributes to suppressing these instabilities. The two factors of the finite thickness and directional rotation of the magnetic field cooperate to enhance suppression, with the finite thickness playing a role only when the orientation of the magnetic field is time varying. The suppression becomes stronger as the driving magnetic field rotates faster, and all modes are suppressed, in contrast to the case of a non-rotating magnetic field, for which the vertical mode cannot be suppressed. This implies that the dynamically alternate configuration of a Theta-pinch and a Z-pinch may be applicable to the concept of Theta-Z liner inertial fusion.

  20. Dynamic mask for producing uniform or graded-thickness thin films

    DOEpatents

    Folta, James A [Livermore, CA

    2006-06-13

    A method for producing single layer or multilayer films with high thickness uniformity or thickness gradients. The method utilizes a moving mask which blocks some of the flux from a sputter target or evaporation source before it deposits on a substrate. The velocity and position of the mask is computer controlled to precisely tailor the film thickness distribution. The method is applicable to any type of vapor deposition system, but is particularly useful for ion beam sputter deposition and evaporation deposition; and enables a high degree of uniformity for ion beam deposition, even for near-normal incidence of deposition species, which may be critical for producing low-defect multilayer coatings, such as required for masks for extreme ultraviolet lithography (EUVL). The mask can have a variety of shapes, from a simple solid paddle shape to a larger mask with a shaped hole through which the flux passes. The motion of the mask can be linear or rotational, and the mask can be moved to make single or multiple passes in front of the substrate per layer, and can pass completely or partially across the substrate.

  1. Ultrasound evaluation of muscle thickness changes in the external oblique, internal oblique, and transversus abdominis muscles considering the influence of posture and muscle contraction.

    PubMed

    Sugaya, Tomoaki; Abe, Yota; Sakamoto, Masaaki

    2014-09-01

    [Purpose] The aim of this study was to investigate muscle thickness changes in the external oblique (EO), internal oblique (IO), and transversus abdominis (TrA) muscles between the neutral position and trunk rotation, under a state of rest without voluntary contractions, and isometric contractions to both sides with resistance of 50% of the maximum trunk rotation strength. [Subjects] The subjects of this study were 21 healthy young men. [Methods] Muscle thickness changes in the EO, IO, and TrA in each position and state were evaluated by ultrasound. The range of motion at maximum trunk rotation and the maximum strength of trunk rotation were measured using a hand-held dynamometer. [Results] In the neutral position and at 50% trunk rotation to the right side, the thicknesses of the IO and TrA significantly increased with resistance. In both states, the thicknesses of the IO and TrA significantly increased at 50% trunk rotation to the right side. [Conclusion] The muscular contractions of the IO and TrA were stronger during ipsilateral rotation than in the neutral position and with resistance than at rest. Moreover, the muscular contraction was strongest in the resistive state during ipsilateral rotation.

  2. Degree of tendon degeneration and stage of rotator cuff disease.

    PubMed

    Jo, Chris Hyunchul; Shin, Won Hyoung; Park, Ji Wan; Shin, Ji Sun; Kim, Ji Eun

    2017-07-01

    While tendon degeneration has been known to be an important cause of rotator cuff disease, few studies have objectively proven the association of tendon degeneration and rotator cuff disease. The purpose of this study was to investigate changes of tendon degeneration with respect to the stage of rotator cuff disease. A total of 48 patients were included in the study: 12 with tendinopathy, 12 with a partial-thickness tear (pRCT), 12 with a full-thickness tear (fRCT), and 12 as the control. A full-thickness supraspinatus tendon sample was harvested en bloc from the middle portion between the lateral edge and the musculotendinous junction of the tendon using a biopsy punch with a diameter of 3 mm. Harvested samples were evaluated using a semi-quantitative grading scale with 7 parameters after haematoxylin and eosin staining. There was no significant difference in age, gender, symptom duration, and Kellgren-Lawrence grade between the groups except for the global fatty degeneration index. All of the seven parameters were significantly different between the groups and could be categorized as follows: early responders (fibre structure and arrangement), gradual responder (rounding of the nuclei), after-tear responders (cellularity, vascularity, and stainability), and late responder (hyalinization). The total degeneration scores were not significantly different between the control (6.08 ± 1.16) and tendinopathy (6.67 ± 1.83) (n.s.). However, the score of pRCT group (10.42 ± 1.31) was greater than that of tendinopathy (P < 0.001), and so was the score of fRCT (12.33 ± 1.15) than that of pRCT (p = 0.009). This study showed that the degeneration of supraspinatus tendon increases as the stage of rotator cuff disease progresses from tendinopathy to pRCT, and then to fRCT. The degree of degeneration of tendinopathy was not different from that of normal but aged tendons, and significant tendon degeneration began from the stage of pRCT. The clinical relevance of the study is that strategies and goals of the treatment for rotator cuff disease should be specific to its stage, in order to prevent disease progression for tendinopathy and pRCT, as well to restore the structural integrity for fRCT. Diagnostic, Level I.

  3. Viscous free-surface flows on rotating elliptical cylinders

    NASA Astrophysics Data System (ADS)

    Li, Weihua; Carvalho, Marcio S.; Kumar, Satish

    2017-09-01

    The flow of liquid films on rotating discrete objects having complicated cross sections is encountered in coating processes for a broad variety of products. To advance fundamental understanding of this problem, we study viscous free-surface flows on rotating elliptical cylinders by solving the governing equations in a rotating reference frame using the Galerkin finite-element method. Results of our simulations agree well with Hunt's maximum-load condition [Hunt, Numer. Methods Partial Differ. Eqs. 24, 1094 (2008), 10.1002/num.20307], which was obtained in the absence of surface tension and inertia. The simulations are also used to track the transient behavior of the free surface. For O (1 ) cylinder aspect ratios, cylinder rotation results in a droplike liquid bulge hanging on the upward-moving side of the cylinder. This bulge shrinks in size due to surface tension provided that the liquid load is smaller than a critical value, leaving a relatively smooth coating on the cylinder. A decrease in cylinder aspect ratio leads to larger gradients in film thickness, but enhances the rate of bulge shrinkage and thus shortens the time required to obtain a smooth coating. Moreover, with a suitably chosen time-dependent rotation rate, more liquid can be supported by the cylinder relative to the constant-rotation-rate case. For cylinders with even smaller aspect ratios, film rupture and liquid shedding may occur over the cylinder tips, so simultaneous drying and rotation along with the introduction of Marangoni stresses will likely be especially important for obtaining a smooth coating.

  4. Piezoelectric coupling factor calculations for plates of langatate driven in simple thickness modes by lateral-field-excitation.

    PubMed

    Khan, Ajmal; Ballato, Arthur

    2002-07-01

    Piezoelectric coupling factors for langatate (La3Ga5.5Ta0.5O14) single-crystals driven by lateral-field-excitation have been calculated using the extended Christoffel-Bechmann method. Calculations were made using published materials constants. The results are presented in terms of the lateral piezoelectric coupling factor as functions of in-plane (azimuthal) rotation angle for the three simple thickness vibration modes of some non-rotated, singly-rotated, and doubly-rotated orientations. It is shown that lateral-field-excitation offers the potential to eliminate unwanted vibration modes and to achieve considerably greater piezoelectric coupling versus thickness-field-excitation for the rotated cuts considered and for a doubly-rotated cut that is of potential technological interest.

  5. Comparison of central corneal thickness measurement using ultrasonic pachymetry, rotating Scheimpflug camera, and scanning-slit topography.

    PubMed

    Sedaghat, Mohammad Reza; Daneshvar, Ramin; Kargozar, Abbas; Derakhshan, Akbar; Daraei, Mona

    2010-12-01

    To evaluate and compare central corneal thickness measurements using rotating Scheimpflug camera, scanning-slit topography, and ultrasound pachymetry in virgin, healthy corneas. Prospective, observational, cross-sectional study. Central corneal thickness in 157 healthy eyes of 157 patients without ocular abnormalities other than refractive errors was measured, in a sequential order, once with rotating Scheimpflug camera and scanning-slit topography and 3 times with ultrasound pachymetry as the last part of examination. All measurements were performed by a single experienced examiner. The results from scanning-slit topography are given with and without correction for "acoustic correction factor" of 0.92. The average measurements of central corneal thickness by rotating Scheimpflug imaging, scanning-slit pachymetry, and ultrasound were 537.15 ± 32.98 μm, 542.06 ± 39.04 μm, and 544.07 ± 34.75 μm, respectively. The mean differences between modalities were 6.92 μm between rotating Scheimpflug and ultrasound (P < .0001), 2.01 μm between corrected scanning-slit and ultrasound (P = .204), and 4.91 μm between corrected scanning-slit and rotating Scheimpflug imaging (P = .001). According to Bland-Altman analysis, highest agreement was between ultrasonic and rotating Scheimpflug pachymetry. In the assessment of normal corneas, rotating Scheimpflug topography measures central corneal thickness values with higher agreement to ultrasound pachymetry. Copyright © 2010 Elsevier Inc. All rights reserved.

  6. Retear rate in the late postoperative period after arthroscopic rotator cuff repair.

    PubMed

    Kim, Jae Hwa; Hong, In Tae; Ryu, Keun Jung; Bong, Sun Tae; Lee, Yoon Seok; Kim, Jang Hwan

    2014-11-01

    Few clinical studies have evaluated the integrity of repaired tendons and identified the timing of retears through the use of serial imaging. Retears after arthroscopic rotator cuff repair are uncommon in the late postoperative period (after 3 months). Case series; Level of evidence, 4. Among 221 arthroscopic rotator cuff repairs that were performed at a single hospital between May 2010 and February 2012, 61 were involved in this study. Rotator cuff tears consisted of 12 small, 31 medium, 8 large, and 6 massive rotator cuff tears. Additionally, 4 isolated subscapularis tears were included. For clinical evaluation, all patients were assessed both preoperatively and postoperatively by use of the University of California-Los Angeles Shoulder Rating Scale, absolute and relative Constant scores, and American Shoulder and Elbow Surgeons score; active range of motion was assessed as well. For radiological evaluation, all 61 patients had a magnetic resonance imaging (MRI) evaluation at 3 months postoperatively. Among them, 23 patients were evaluated for repaired tendon integrity on postoperative MRI at a minimum of 1 year after surgery (mean, 14.1 months; range, 12-19 months), and results were classified according to the Sugaya classification: type I, sufficient thickness with homogeneously low intensity on each image; type II, sufficient thickness, partial high-intensity area; type III, less than half the thickness without discontinuity; type IV, minor discontinuity; and type V, major discontinuity. The remaining 38 patients, who refused to undergo MRI again for financial reasons, were evaluated through ultrasound. Statistically significant clinical improvements were observed after surgery. The MRI conducted at 3 months postoperatively identified 9 patients with Sugaya type I, 28 patients with type II, and 24 patients with type III repairs. No patients showed Sugaya type IV or V repairs at postoperative 3 months. Thirty-seven patients who had shown Sugaya type I or II repairs on 3-month postoperative MRI had no retear on imaging study at a minimum of 1 year. Of 24 patients who had shown type III repairs on 3-month postoperative MRI, 1 patient exhibited retear (Sugaya type IV) on 1-year postoperative MRI and 3 patients showed full-thickness retear on 1-year postoperative ultrasonography. All 4 of these patients had had large to massive tears preoperatively. Retears occurred infrequently in the late postoperative period (after 3 months) in well-healed tendons that had shown intact cuff repair integrity with sufficient mechanical and biological healing within the first 3 postoperative months. © 2014 The Author(s).

  7. Relation Between Subacromial Bursitis on Ultrasonography and Efficacy of Subacromial Corticosteroid Injection in Rotator Cuff Disease: A Prospective Comparison Study.

    PubMed

    Lee, Doo-Hyung; Hong, Ji Yeon; Lee, Michael Young; Kwack, Kyu-Sung; Yoon, Seung-Hyun

    2017-05-01

    To evaluate the correlations between subacromial bursitis (bursal thickening and effusion) on ultrasonography and its response to subacromial corticosteroid injection in patients with rotator cuff disease. Prospective, longitudinal comparison study. University-affiliated tertiary care hospital. Patients with rotator cuff disease (N=69) were classified into 3 groups based on ultrasonographic findings; (1) normative bursa group (group 1, n=23): bursa and effusion thickness <1mm; (2) bursa thickening group (group 2, n=22): bursa thickness >2mm and effusion thickness <1mm; and (3) bursa effusion group (group 3, n=24): bursa thickness <1mm and effusion thickness >2mm. A single subacromial injection with 20mg of triamcinolone acetonide. Visual analog scale (VAS) of shoulder pain, Shoulder Disability Questionnaire (SDQ), angles of active shoulder range of motion (flexion, abduction, external rotation, and internal rotation), and bursa and effusion thickness at pre- and posttreatment at week 8. There were no significant differences between the 3 groups in demographic characteristics pretreatment. Groups 2 and 3 showed a significant difference compared with group 1 in changes on the VAS and abduction; group 3 showed a significant difference compared with group 1 in changes of the SDQ, internal rotation, and external rotation; and all groups showed significant differences when compared with each other (groups 1 and 3, 2 and 3, and 1 and 2) in changes of thickness. A patient with ultrasonographic observation of subacromial bursitis, instead of normative bursa, can expect better outcome with subacromial corticosteroid injection. Therefore, we recommend a careful selection of patients using ultrasonography prior to injection. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Do Magnetic Resonance Imaging Characteristics of Full-Thickness Rotator Cuff Tears Correlate With Sleep Disturbance?

    PubMed

    Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S

    2017-11-01

    Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.

  9. Alterations of the Deltoid Muscle After Open Versus Arthroscopic Rotator Cuff Repair.

    PubMed

    Cho, Nam Su; Cha, Sang Won; Rhee, Yong Girl

    2015-12-01

    Open repair can be more useful than arthroscopic repair for immobile and severely retracted, large to massive rotator cuff tears. However, it is not known whether the deltoid muscle is altered after open repair or to what extent the deltoid origin remains detached after surgery. To compare postoperative alterations of the deltoid muscle in open versus arthroscopic repair for severely retracted, large to massive rotator cuff tears. Case-control study; Level of evidence, 3. Enrolled in this study were 135 patients who underwent surgical repair for severely retracted, large to massive rotator cuff tears and who had routine follow-up MRIs at least 6 months after surgery. Open repairs were performed in 56 cases and arthroscopic repairs in 79 cases. The detachment and thickness of the deltoid muscle at its proximal origin were recorded in 5 zones on MRI. The alterations of the deltoid muscle and postoperative integrity of the repaired rotator cuff were evaluated. Partial detachment of the deltoid occurred in 1 patient (1.8%) in the open group and in 2 patients (2.5%) in the arthroscopic group (P = .80). All the partial detachments occurred in zones 2 and 3. Attenuation of the proximal origin of the deltoid was found in 3 patients (5.4%) in the open group and in 4 patients (5.1%) in the arthroscopic group (P = .87). Atrophy of the deltoid muscle was shown in 3 patients (5.4%) in the open group and 4 patients (5.1%) in the arthroscopic group (P = .61). The retear rate of the repaired cuff was 30.4% (17/56) in the open group and 38.0% (30/79) in the arthroscopic group (P = .74). Between open and arthroscopic repair for severely retracted, large to massive rotator cuff tears, there was no significant difference in detachment of the deltoid origin and alterations of the deltoid muscle after repair. Postoperative alterations of the deltoid occurred in arthroscopic surgery as well as in open surgery. For immobile massive rotator cuff tear, open repair is an acceptable technique as long as the deltoid muscle is meticulously reattached after surgery. © 2015 The Author(s).

  10. Patient self-assessed shoulder comfort and function and active motion are not closely related to surgically documented rotator cuff tear integrity.

    PubMed

    Hsu, Jason E; Tang, Anna; Matsen, Frederick A

    2017-11-01

    The rationale for rotator cuff repair surgery is that better integrity of the cuff should be associated with better comfort and function. However, in patients with cuff disease, there is not good evidence that the degree of rotator cuff integrity is closely associated with the shoulder's comfort, function, or active motion. The goal of this study was to explore these relationships in shoulders with surgically documented cuff disease. In 55 shoulders having surgery for cuff-related symptoms, we correlated the preoperative Simple Shoulder Test score with the objectively measured preoperative active shoulder motion and with the integrity of the cuff observed at surgery. The 16 shoulders with tendinosis or partial-thickness tears had an average Simple Shoulder Test score of 3.7 ± 3.3, active abduction of 111° ± 38°, and active flexion of 115° ± 36°. The corresponding values were 3.6 ± 2.8, 94° ± 47°, and 94° ± 52° for the 22 full-thickness supraspinatus tears and 3.9 ± 2.7, 89° ± 39°, and 100° ± 39° for the 17 supraspinatus and infraspinatus tears. In this study, surgically observed cuff integrity was not strongly associated with the shoulder's comfort or function. Whereas surgeons often seek to improve the integrity of the rotator cuff, the management of patients with rotator cuff disorders needs to be informed by a better understanding of the factors other than cuff integrity that influence the comfort and functioning of shoulders with cuff disease. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Scroll wave dynamics in a three-dimensional cardiac tissue model: roles of restitution, thickness, and fiber rotation.

    PubMed Central

    Qu, Z; Kil, J; Xie, F; Garfinkel, A; Weiss, J N

    2000-01-01

    Scroll wave (vortex) breakup is hypothesized to underlie ventricular fibrillation, the leading cause of sudden cardiac death. We simulated scroll wave behaviors in a three-dimensional cardiac tissue model, using phase I of the Luo-Rudy (LR1) action potential model. The effects of action potential duration (APD) restitution, tissue thickness, filament twist, and fiber rotation were studied. We found that APD restitution is the major determinant of scroll wave behavior and that instabilities arising from APD restitution are the main determinants of scroll wave breakup in this cardiac model. We did not see a "thickness-induced instability" in the LR1 model, but a minimum thickness is required for scroll breakup in the presence of fiber rotation. The major effect of fiber rotation is to maintain twist in a scroll wave, promoting filament bending and thus scroll breakup. In addition, fiber rotation induces curvature in the scroll wave, which weakens conduction and further facilitates wave break. PMID:10827961

  12. Rotational Augmentation on a 2.3 MW Rotor Blade with Thick Flatback Airfoil Cross-Sections: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schreck, S.; Fingersh, L.; Siegel, K.

    2013-01-01

    Rotational augmentation was analyzed for a 2.3 MW wind turbine, which was equipped with thick flatback airfoils at inboard radial locations and extensively instrumented for acquisition of time varying surface pressures. Mean aerodynamic force and surface pressure data were extracted from an extensive field test database, subject to stringent criteria for wind inflow and turbine operating conditions. Analyses of these data showed pronounced amplification of aerodynamic forces and significant enhancements to surface pressures in response to rotational influences, relative to two-dimensional, stationary conditions. Rotational augmentation occurrence and intensity in the current effort was found to be consistent with that observedmore » in previous research. Notably, elevated airfoil thickness and flatback design did not impede rotational augmentation.« less

  13. Multihelix rotating shield brachytherapy for cervical cancer

    PubMed Central

    Dadkhah, Hossein; Kim, Yusung; Wu, Xiaodong; Flynn, Ryan T.

    2015-01-01

    Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D90 of HR-CTV) were the two metrics used as the basis for evaluation and comparison. For all the generated treatment plans, the D90 of the HR-CTV in units of equivalent dose in 2 Gy fractions (EQD2) was escalated until the D2cc (minimum dose to hottest 2 cm3) tolerance of either the bladder (90 Gy3), rectum (75 Gy3), or sigmoid colon (75 Gy3) was reached. Results: Treatment time changed for H-RSBT versus S-RSBT by −7.62% to 1.17% with an average change of −2.8%, thus H-RSBT treatments times tended to be shorter than for S-RSBT. The HR-CTV D90 also changed by −2.7% to 2.38% with an average of −0.65%. Conclusions: H-RSBT is a mechanically feasible delivery technique for use in the curved applicators needed for cervical cancer brachytherapy. S-RSBT and H-RSBT were clinically equivalent for all patients considered, with the H-RSBT technique tending to require less time for delivery. PMID:26520749

  14. Effects of fixture rotation on coating uniformity for high-performance optical filter fabrication

    NASA Astrophysics Data System (ADS)

    Rubin, Binyamin; George, Jason; Singhal, Riju

    2018-04-01

    Coating uniformity is critical in fabricating high-performance optical filters by various vacuum deposition methods. Simple and planetary rotation systems with shadow masks are used to achieve the required uniformity [J. B. Oliver and D. Talbot, Appl. Optics 45, 13, 3097 (2006); O. Lyngnes, K. Kraus, A. Ode and T. Erguder, in `Method for Designing Coating Thickness Uniformity Shadow Masks for Deposition Systems with a Planetary Fixture', 2014 Technical Conference Proceedings, Optical Coatings, August 13, 2014, DOI: 10.14332/svc14.proc.1817.]. In this work, we discuss the effect of rotation pattern and speed on thickness uniformity in an ion beam sputter deposition system. Numerical modeling is used to determine statistical distribution of random thickness errors in coating layers. The relationship between thickness tolerance and production yield are simulated theoretically and demonstrated experimentally. Production yields for different optical filters produced in an ion beam deposition system with planetary rotation are presented. Single-wavelength and broadband optical monitoring systems were used for endpoint monitoring during filter deposition. Limitations of thickness tolerances that can be achieved in systems with planetary rotation are shown. Paths for improving production yield in an ion beam deposition system are described.

  15. Rotator cuff crepitus: could Codman really feel a cuff tear?

    PubMed

    Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J

    2014-07-01

    The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.

  16. Rotational Flap to Enhance Buccal Gingival Thickness and Implant Emergence Profile in the Esthetic Zone: Two Cases Reports

    PubMed Central

    AL-Juboori, Mohammed Jasim

    2017-01-01

    Objective: Many techniques have been developed to enhance the gingival thickness, gingival level and emergence profile around the implant in the esthetic zone. Introduction: In this study, a buccal rotational flap was used to improve the implant site in the esthetic zone and increase gingival tissue thickness. Methods: Two cases involved the use of a rotational flap during second-stage implant surgery, one case involved the use of a temporary crown with a healing abutment, and another case involved the use of a healing abutment. Result: The cases were followed up until the final crown was placed. The implant site was improved in 2 cases; the gingival thickness increased, the gingival level was enhanced and the emergence profile was developed. Conclusion: Many factors affect the results of a rotational flap; some factors are surgical, while others are prosthetic, biological and anatomical. PMID:28839477

  17. Magneto-optical microcavity with Au plasmonic layer

    NASA Astrophysics Data System (ADS)

    Mikhailova, T. V.; Lyashko, S. D.; Tomilin, S. V.; Karavainikov, A. V.; Prokopov, A. R.; Shaposhnikov, A. N.; Berzhansky, V. N.

    2017-11-01

    Optical and Faraday rotation spectra of magneto-optical microcavity coated with Au plasmonic layer of gradient thickness were investigated theoretically and experimentally. It was shown that the Tamm plasmon-polaritons mode forms near the long-wavelength edge of photonic band gap. The presence of Au coating of thickness of 90.4 nm increase the Faraday rotation at Tamm plasmon-polaritons and cavity resonances in 1.3 and 7 times, respectively. By transfer matrix method it were found that the incorporation of SiO2 buffer layer with a thickness in the range from 155 to 180 nm between microcavity and Au coating leads to the strong coupling between cavity mode and Tamm plasmon-polaritons. In this case, one or two resonances arise in the vicinity of the cavity mode depending on the thickness of plasmonic layer. The Faraday rotation for coupled mode in twice less than the value of rotation for single cavity mode.

  18. Femtosecond laser subsurface scleral treatment in cadaver human sclera and evaluation using two-photon and confocal microscopy

    NASA Astrophysics Data System (ADS)

    Sun, Hui; Fan, Zhongwei; Yan, Ying; Lian, Fuqiang; Kurtz, Ron; Juhasz, Tibor

    2016-03-01

    Glaucoma is the second-leading cause of blindness worldwide and is often associated with elevated intraocular pressure (IOP). Partial-thickness drainage channels can be created with femtosecond laser in the translucent sclera for the potential treatment of glaucoma. We demonstrate the creation of partial-thickness subsurface drainage channels with the femtosecond laser in the cadaver human eyeballs and describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. A femtosecond laser operating at a wavelength of 1700 nm was scanned along a rectangular raster pattern to create the partial thickness subsurface drainage channels in the sclera of cadaver human eyes. Analysis of the dimensions and location of these channels is important in understanding their effects. We describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. High-resolution images, hundreds of microns deep in the sclera, were obtained to allow determination of the shape and dimension of such partial thickness subsurface scleral channels. Our studies suggest that the confocal and two-photon microscopy can be used to investigate femtosecond-laser created partial-thickness drainage channels in the sclera of cadaver human eyes.

  19. Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.

    PubMed

    Lee, Ji Hyun; Yoon, Young Cheol; Jee, Sukkyung

    2015-06-01

    Indirect magnetic resonance (MR) arthrography is a non-invasive method for shoulder imaging. However, there are no studies that have examined the diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears in a large patient population. To assess the diagnostic performance of indirect fast spin-echo (FSE) MR arthrography for the diagnosis of rotator cuff tears at 3.0 T. A total of 149 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery were enrolled in this retrospective study. Two musculoskeletal radiologists evaluated images from each patient for the presence of supraspinatus-infraspinatus (SSP-ISP) or subscapularis (SSC) tendon tears. Using the arthroscopic findings as the reference standard, the overall diagnostic performance and detection rates for SSP-ISP and SSC tendon tears were calculated. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSP-ISP tendon tears were 94% and 95%, 89% and 85%, and 93% and 93%, respectively. The sensitivity of imaging for detection of SSP-ISP tendon tears by readers I and II were 100% and 100% for full-thickness tears and 84% and 86% for partial-thickness tears, respectively. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSC tendon tears were 80% and 76%, 89% and 93%, and 85% and 85%, respectively. Indirect MR arthrography is useful for the detection of SSP-ISP and SSC tendon tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Location of Rotator Cuff Tear Initiation: A Magnetic Resonance Imaging Study of 191 Shoulders.

    PubMed

    Jeong, Jeung Yeol; Min, Seul Ki; Park, Keun Min; Park, Yong Bok; Han, Kwang Joon; Yoo, Jae Chul

    2018-03-01

    Degenerative rotator cuff tears (RCTs) are generally thought to originate at the anterior margin of the supraspinatus tendon. However, a recent ultrasonography study suggested that they might originate more posteriorly than originally thought, perhaps even from the isolated infraspinatus (ISP) tendon, and propagate toward the anterior supraspinatus. Hypothesis/Purpose: It was hypothesized that this finding could be reproduced with magnetic resonance imaging (MRI). The purpose was to determine the most common location of degenerative RCTs by using 3-dimensional multiplanar MRI reconstruction. It was assumed that the location of the partial-thickness tears would identify the area of the initiation of full-thickness tears. Cross-sectional study; Level of evidence, 3. A retrospective analysis was conducted including 245 patients who had RCTs (nearly full- or partial-thickness tears) at the outpatient department between January 2011 and December 2013. RCTs were measured on 3-dimensional multiplanar reconstruction MRI with OsiriX software. The width and distance from the biceps tendon to the anterior margin of the tear were measured on T2-weighted sagittal images. In a spreadsheet, columns of consecutive numbers represented the size of each tear (anteroposterior width) and their locations with respect to the biceps brachii tendon. Data were pooled to graphically represent the width and location of all tears. Frequency histograms of the columns were made to visualize the distribution of tears. The tears were divided into 2 groups based on width (group A, <10 mm; group B, <20 and ≥10 mm) and analyzed for any differences in location related to size. The mean width of all RCTs was 11.9 ± 4.1 mm, and the mean length was 11.1 ± 5.0 mm. Histograms showed the most common location of origin to be 9 to 10 mm posterior to the biceps tendon. The histograms of groups A and B showed similar tear location distributions, indicating that the region approximately 10 mm posterior to the biceps tendon is the most common site of tear initiation. These results demonstrate that degenerative RCTs most commonly originate from approximately 9 to 10 mm posterior to the biceps tendon.

  1. Measuring Thicknesses of Wastewater Films

    NASA Technical Reports Server (NTRS)

    Schubert, F. H.; Davenport, R. J.

    1987-01-01

    Sensor determines when thickness of film of electrically conductive wastewater on rotating evaporator drum exceeds preset value. Sensor simple electrical probe that makes contact with liquid surface. Made of materials resistant to chemicals in liquid. Mounted on shaft in rotating cylinder, liquid-thickness sensor extends toward cylinder wall so tip almost touches. Sensor body accommodates probe measuring temperature of evaporated water in cylinder.

  2. Clinical effectiveness, quality of life and cost-effectiveness of Flaminal® versus Flamazine® in the treatment of partial thickness burns: study protocol for a randomized controlled trial.

    PubMed

    Rashaan, Zjir M; Krijnen, Pieta; van den Akker-van Marle, M Elske; van Baar, Margriet E; Vloemans, Adrianus F P; Dokter, Jan; Tempelman, Fenike R H; van der Vlies, Cees H; Breederveld, Roelf S

    2016-03-05

    Partial thickness burns are painful, difficult to manage and can have a negative effect on quality of life through scarring, permanent disfigurement and loss of function. The aim of burn treatment in partial thickness burns is to save lives, stimulate wound healing by creating an optimumly moist wound environment, to have debriding and analgesic effects, protect the wound from infection and be convenient for the patient and caregivers. However, there is no consensus on the optimal treatment of partial thickness wounds. Flaminal® and Flamazine® are two standard treatment options that provide the above mentioned properties in burn treatment. Nevertheless, no randomized controlled study has yet compared these two common treatment modalities in partial thickness burns. Thus, the aim of this study is to evaluate the clinical effectiveness, quality of life and cost-effectiveness of Flaminal® versus Flamazine® in the treatment of partial thickness burns. In this two-arm open multi-center randomized controlled trial, 90 patients will be randomized between Flaminal® and Flamazine® and followed for 12 months. The study population will consist of competent or temporarily non-competent (because of sedation and/or intubation) patients, 18 years of age or older, with acute partial thickness burns and a total body surface area (TBSA) of less than 30 %. The main study outcome is time to complete re-epithelialization (greater than 95 %). Secondary outcome measures include need for grafting, wound colonization/infection, number of dressing changes, pain and anxiety, scar formation, health-related quality of life (HRQoL), and costs. This study will contribute to the optimal treatment of patients with partial thickness burn wounds and will provide evidence on the (cost-)effectiveness and quality of life of Flaminal® versus Flamazine® in the treatment of partial thickness burns. Netherlands Trial Register NTR4486 , registered on 2 April 2014.

  3. Shoulder-specific outcomes 1 year after nontraumatic full-thickness rotator cuff repair: a systematic literature review and meta-analysis.

    PubMed

    Gurnani, Navin; van Deurzen, Derek F P; van den Bekerom, Michel P J

    2017-10-01

    Nontraumatic full-thickness rotator cuff tears are commonly initially treated conservatively. If conservative treatment fails, rotator cuff repair is a viable subsequent option. The objective of the present meta-analysis is to evaluate the shoulder-specific outcomes one year after arthroscopic or mini-open rotator cuff repair of nontraumatic rotator cuff tears. A literature search was conducted in PubMed and EMBASE within the period January 2000 to January 2017. All studies measuring the clinical outcome at 12 months after nontraumatic rotator cuff repair of full-thickness rotator cuff tears were listed. We included 16 randomized controlled trials that met our inclusion criteria with a total of 1.221 shoulders. At 12 months after rotator cuff repair, the mean Constant score had increased 29.5 points; the mean American Shoulder and Elbow Score score increased by 38.6 points; mean Simple Shoulder Test score was 5.6 points; mean University of California Los Angeles score improved by 13.0 points; and finally, mean Visual Analogue Scale score decreased by 4.1 points. Based on this meta-analysis, significant improvements in the shoulder-specific indices are observed 12 months after nontraumatic arthroscopic or mini-open rotator cuff repair.

  4. Experimental analysis and flow visualization of a thin liquid film on a stationary and rotating disk

    NASA Technical Reports Server (NTRS)

    Thomas, S.; Faghri, A.; Hankey, W.

    1991-01-01

    The mean thickness of a thin liquid film of deionized water with a free surface on a stationary and rotating horizontal disk has been measured with a nonobtrusive capacitance technique. The measurements were taken when the rotational speed ranged from 0-300 rpm and the flow rate varied from 7.0-15.0 lpm. A flow visualization study of the thin film was also performed to determine the characteristics of the waves on the free surface. When the disk was stationary, a circular hydraulic jump was present on the disk. Upstream from the jump, the film thickness was determined by the inertial and frictional forces on the fluid, and the radial spreading of the film. The surface tension at the edge of the disk affected the film thickness downstream from the jump. For the rotating disk, the film thickness was dependent upon the inertial and frictional forces near the center of the disk and the centrifugal forces near the edge of the disk.

  5. Effect of deltoid tension and humeral version in reverse total shoulder arthroplasty: a biomechanical study.

    PubMed

    Henninger, Heath B; Barg, Alexej; Anderson, Andrew E; Bachus, Kent N; Tashjian, Robert Z; Burks, Robert T

    2012-04-01

    No clear recommendations exist regarding optimal humeral component version and deltoid tension in reverse total shoulder arthroplasty (TSA). A biomechanical shoulder simulator tested humeral versions (0°, 10°, 20° retroversion) and implant thicknesses (-3, 0, +3 mm from baseline) after reverse TSA in human cadavers. Abduction and external rotation ranges of motion as well as abduction and dislocation forces were quantified for native arms and arms implanted with 9 combinations of humeral version and implant thickness. Resting abduction angles increased significantly (up to 30°) after reverse TSA compared with native shoulders. With constant posterior cuff loads, native arms externally rotated 20°, whereas no external rotation occurred in implanted arms (20° net internal rotation). Humeral version did not affect rotational range of motion but did alter resting abduction. Abduction forces decreased 30% vs native shoulders but did not change when version or implant thickness was altered. Humeral center of rotation was shifted 17 mm medially and 12 mm inferiorly after implantation. The force required for lateral dislocation was 60% less than anterior and was not affected by implant thickness or version. Reverse TSA reduced abduction forces compared with native shoulders and resulted in limited external rotation and abduction ranges of motion. Because abduction force was reduced for all implants, the choice of humeral version and implant thickness should focus on range of motion. Lateral dislocation forces were less than anterior forces; thus, levering and inferior/posterior impingement may be a more probable basis for dislocation (laterally) than anteriorly directed forces. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. Rotator Cuff Repair in Adolescent Athletes.

    PubMed

    Azzam, Michael G; Dugas, Jeffrey R; Andrews, James R; Goldstein, Samuel R; Emblom, Benton A; Cain, E Lyle

    2018-04-01

    Rotator cuff tears are rare injuries in adolescents but cause significant morbidity if unrecognized. Previous literature on rotator cuff repairs in adolescents is limited to small case series, with few data to guide treatment. Adolescent patients would have excellent functional outcome scores and return to the same level of sports participation after rotator cuff repair but would have some difficulty with returning to overhead sports. Case series; Level of evidence 4. A retrospective search of the practice's billing records identified all patients participating in at least 1 sport who underwent rotator cuff repair between 2006 and 2014 with an age <18 years at the time of surgery and a minimum follow-up of 2 years. Clinical records were evaluated for demographic information, and telephone follow-up was obtained regarding return to play, performance, other surgery and complications, a numeric pain rating scale (0-10) for current shoulder pain, American Shoulder and Elbow Surgeons (ASES) Shoulder Assessment Form, and the Western Ontario Rotator Cuff Index. Thirty-two consecutive adolescent athletes (28 boys and 4 girls) with a mean age of 16.1 years (range, 13.2-17.9 years) met inclusion criteria. Twenty-nine patients (91%) had a traumatic event, and 27 of these patients (93%) had no symptoms before the trauma. The most common single tendon injury was to the supraspinatus (21 patients, 66%), of which 2 were complete tendon tears, 1 was a bony avulsion of the tendon, and 18 were high-grade partial tears. Fourteen patients (56%) underwent single-row repair of their rotator cuff tear, and 11 (44%) underwent double-row repair. All subscapularis injuries were repaired in open fashion, while all other tears were repaired arthroscopically. Twenty-seven patients (84%) completed the outcome questionnaires at a mean 6.2 years after surgery (range, 2-10 years). The mean ASES score was 93 (range, 65-100; SD = 9); mean Western Ontario Rotator Cuff Index, 89% (range, 60%-100%; SD = 13%); and mean numeric pain rating, 0.3 (range, 0-3; SD = 0.8). Overall, 25 patients (93%) returned to the same level of play or higher. Among overhead athletes, 13 (93%) were able to return to the same level of play, but 8 (57%) were forced to change positions. There were no surgical complications, but 2 patients did undergo a subsequent operation. Surgical repair of high-grade partial-thickness and complete rotator cuff tears yielded successful outcomes among adolescents, with excellent functional outcomes at midterm follow-up. However, overhead athletes may have difficulty playing the same position after surgery.

  7. The Oxford Medial Partial Knee Replacement. The rationale for a femur first technique.

    PubMed

    Shakespeare, David; Waite, Jon

    2012-12-01

    The Oxford Medial Partial Knee Replacement (PKR) has been in clinical use for more than 20 years. The current surgical technique requires a number of judgements to be made, and even in the most experienced hands surgery can be challenging. We present an alternative surgical technique, which we believe addresses the unpredictability of the current method. The technique is based on precise femoral positioning prior to tibial resection. A prospective series of 125 Oxford Medial PKRs was performed using this new technique and a radiographical analysis was performed. We used meniscal thickness, meniscal position and femoral position as measures of reproducibility of the procedure. Variability in meniscal thickness has been minimised with a 3mm meniscal bearing used in 21 knees (15%), 4mm (the target thickness) in 73 knees (59%) and 5mm in 30 knees (24%). The mean meniscal position relative to the tibial tray upright was 2mm (SD 1mm). Femoral component position relative to the tibial tray, which defines the excursion of the meniscus was also assessed. Mean coronal plane alignment was 2° of valgus (SD 2.8). Mean flexion/extension was 3.8° (SD 3.1). The mean rotation was 10° internal (SD 5°). We believe this new technique makes this procedure more reproducible, and should be considered as a viable alternative to the current recommended technique. It may be a better technique for those surgeons who are relatively inexperienced with this prosthesis. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Effect of evaporative surface cooling on thermographic assessment of burn depth

    NASA Technical Reports Server (NTRS)

    Anselmo, V. J.; Zawacki, B. E.

    1977-01-01

    Differences in surface temperature between evaporating and nonevaporating, partial- and full-thickness burn injuries were studied in 20 male, white guinea pigs. Evaporative cooling can disguise the temperature differential of the partial-thickness injury and lead to a false full-thickness diagnosis. A full-thickness burn with blister intact may retain enough heat to result in a false partial-thickness diagnosis. By the fourth postburn day, formation of a dry eschar may allow a surface temperature measurement without the complication of differential evaporation. For earlier use of thermographic information, evaporation effects must be accounted for or eliminated.

  9. Multihelix rotating shield brachytherapy for cervical cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dadkhah, Hossein; Kim, Yusung; Flynn, Ryan T., E-mail: ryan-flynn@uiowa.edu

    Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as amore » feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for evaluation and comparison. For all the generated treatment plans, the D{sub 90} of the HR-CTV in units of equivalent dose in 2 Gy fractions (EQD2) was escalated until the D{sub 2cc} (minimum dose to hottest 2 cm{sup 3}) tolerance of either the bladder (90 Gy{sub 3}), rectum (75 Gy{sub 3}), or sigmoid colon (75 Gy{sub 3}) was reached. Results: Treatment time changed for H-RSBT versus S-RSBT by −7.62% to 1.17% with an average change of −2.8%, thus H-RSBT treatments times tended to be shorter than for S-RSBT. The HR-CTV D{sub 90} also changed by −2.7% to 2.38% with an average of −0.65%. Conclusions: H-RSBT is a mechanically feasible delivery technique for use in the curved applicators needed for cervical cancer brachytherapy. S-RSBT and H-RSBT were clinically equivalent for all patients considered, with the H-RSBT technique tending to require less time for delivery.« less

  10. Superior Labrum Anterior Posterior Lesions and Associated Injuries

    PubMed Central

    Beyzadeoglu, Tahsin; Circi, Esra

    2015-01-01

    Background: Superior labrum anterior posterior (SLAP) lesions often cause shoulder pain, dysfunction, and instability. Professional athletes require a high level of shoulder function for competition and overhead activities. Purpose: To evaluate elite athletes who had arthroscopic surgery for common shoulder pathologies and SLAP lesions with a follow-up of more than 3 years. The associated intra-articular pathologies and return to play were documented. Study Design: Case series; Level of evidence, 4. Methods: Thirty-five shoulders in 34 elite athletes (4 women and 30 men; mean age, 25 years [range, 18-32 years]) had arthroscopic repair of SLAP lesions and accompanying Bankart or rotator cuff tears between January 2008 and November 2011. The documentation included patient symptoms, physical examination, radiological analysis with radiographs, and magnetic resonance imaging. Shoulder function was evaluated preoperatively and at follow-up using American Shoulder and Elbow Surgeons (ASES) and Kerlan Jobe Orthopaedic Clinic (KJOC) scores. The mean follow-up was 52 months. Results: Isolated SLAP lesions were seen in 17.1% of patients, SLAP lesions and partial cuff tear occurred in 25.7%, associated Bankart lesions in 37.1%, full-thickness rotator cuff tears in 8.6%, Bankart and posterior labrum lesions in 8.6%, and Bankart and full-thickness rotator cuff tears in 2.9%. Return to play was a mean 6.4 ± 1.5 months. The mean postoperative ASES and KJOC scores were 89.6 ± 4.6 and 80.9 ± 6.8, respectively, compared with preoperative scores of 64.0 ± 7.2 and 50.5 ± 10.3 (t test, P < .01). Conclusion: The majority (88.2%) of professional athletes returned to their preinjury levels. SLAP lesions may frequently occur with Bankart lesions and rotator cuff tears. A high rate of return to sport at the same level of athletic performance can be achieved by anatomic repair and effective rehabilitation. PMID:26665050

  11. Superior Labrum Anterior Posterior Lesions and Associated Injuries: Return to Play in Elite Athletes.

    PubMed

    Beyzadeoglu, Tahsin; Circi, Esra

    2015-04-01

    Superior labrum anterior posterior (SLAP) lesions often cause shoulder pain, dysfunction, and instability. Professional athletes require a high level of shoulder function for competition and overhead activities. To evaluate elite athletes who had arthroscopic surgery for common shoulder pathologies and SLAP lesions with a follow-up of more than 3 years. The associated intra-articular pathologies and return to play were documented. Case series; Level of evidence, 4. Thirty-five shoulders in 34 elite athletes (4 women and 30 men; mean age, 25 years [range, 18-32 years]) had arthroscopic repair of SLAP lesions and accompanying Bankart or rotator cuff tears between January 2008 and November 2011. The documentation included patient symptoms, physical examination, radiological analysis with radiographs, and magnetic resonance imaging. Shoulder function was evaluated preoperatively and at follow-up using American Shoulder and Elbow Surgeons (ASES) and Kerlan Jobe Orthopaedic Clinic (KJOC) scores. The mean follow-up was 52 months. Isolated SLAP lesions were seen in 17.1% of patients, SLAP lesions and partial cuff tear occurred in 25.7%, associated Bankart lesions in 37.1%, full-thickness rotator cuff tears in 8.6%, Bankart and posterior labrum lesions in 8.6%, and Bankart and full-thickness rotator cuff tears in 2.9%. Return to play was a mean 6.4 ± 1.5 months. The mean postoperative ASES and KJOC scores were 89.6 ± 4.6 and 80.9 ± 6.8, respectively, compared with preoperative scores of 64.0 ± 7.2 and 50.5 ± 10.3 (t test, P < .01). The majority (88.2%) of professional athletes returned to their preinjury levels. SLAP lesions may frequently occur with Bankart lesions and rotator cuff tears. A high rate of return to sport at the same level of athletic performance can be achieved by anatomic repair and effective rehabilitation.

  12. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma.

    PubMed

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side ( P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  13. The Relationship Between Body Mass Index and Fatty Infiltration in the Shoulder Musculature.

    PubMed

    Dow, David F; Mehta, Kaushal; Xu, Yuanfang; England, Eric

    Fatty infiltration in the rotator cuff muscles has been well studied in the setting of rotator cuff tendon tears to help predict outcomes of surgical repair. Fatty infiltration in the rotator cuff has also been independently correlated to the variables of age and sex. The purpose of our study was to determine if there is a relationship between body mass index and fatty infiltration in patients with no imaging evidence of rotator cuff tendinosis or tear. Radiology reports of all magnetic resonance imaging examinations of the shoulder were searched over a 2-year period. Studies with imaging findings of rotator cuff tendinosis, partial tear, or full thickness tear were excluded from the study, resulting in a total of 143 patients with normal rotator cuffs who were included in the study. These studies were reviewed by consensus by 2 fellowship-trained musculoskeletal radiologists who used the Goutallier 5-stage scoring system to grade the supraspinatus, infraspinatus, subscapularis, teres minor, teres major, and deltoid muscles. Sex was shown not to be significantly associated with fatty infiltration with the exception of the deltoid muscle, which showed a statistically significant increase in fatty infiltration associated with female sex (P = 0.038). Age was shown to be a statistically significant predictor of fatty infiltration for all 6 muscles (P < 0.05). Body mass index was shown to be a statistically significant predictor of fatty infiltration for all of the evaluated shoulder musculature (P < 0.05) with the exception of the teres minor. Our results suggest that increased body mass index is associated with increased fatty infiltration in the supraspinatus, infraspinatus, subscapularis, teres major, and deltoid muscles. This relationship could help guide the decisions of orthopedic surgeons when considering rotator cuff repair.

  14. Recovery and nonrecovery of the untrained state in an exchange-coupled system

    NASA Astrophysics Data System (ADS)

    Jutimoosik, Jaru; Yimnirun, Rattikorn; Setzer, Annette; Esquinazi, Pablo; Stahn, Jochen; Paul, Amitesh

    2015-06-01

    We report depth sensitive investigations of the magnetic interaction between exchange-coupled stacked CoO and ferromagnetic Co bilayers (separated by thick Au layers) as we explore the degree of recovery of the untrained state after the first two field cycles. Such a recovery is expected by field cycling a reorientation field (HRE) along a direction (ΩRE) away from the initial field cooling direction. Measurements as a function of ΩRE and the strength of HRE (along each direction) map the influence of ΩRE on the reversal mechanism in the layers and thereby the degree of recovery. Our results are consistent with the earlier observations in similar systems that was realized with ΩRE=90∘ . We ascribe these partial and/or significant recoveries to the unchanged sense of rotation after initial field cooling of the ferromagnetic magnetization upon each field cycling. Furthermore, in our system, we find that this recovery can be regulated by choosing various other HRE and ΩRE values without changing the rotational sense. The best recipe for recovery is identified for ΩRE=45∘ , that can be achieved partially with HRE=3.0 kOe and remain significant even with HRE=10.0 kOe. In this study we not only understand the fundamental mechanism in the recovery of training, but also instigate its technological prospects by lifting the directional restrictions of the reorientation field.

  15. The use of type 1 collagen scaffold containing stromal cell-derived factor-1 to create a matrix environment conducive to partial-thickness cartilage defects repair.

    PubMed

    Zhang, Wei; Chen, Jialin; Tao, Jiadong; Jiang, Yangzi; Hu, Changchang; Huang, Lu; Ji, Junfeng; Ouyang, Hong Wei

    2013-01-01

    Despite the presence of cartilage-derived mesenchymal stem cells (C-MSCs) and synovial membrane-derived mesenchymal stem cells (SM-MSCs) populations, partial-thickness cartilage defects, in contrast to the full-thickness defects, are devoid of spontaneous repair capacity. This study aims to create an in situ matrix environment conducive to C-MSCs and SM-MSCs to promote cartilage self-repair. Spontaneous repair with MSCs migration into the defect area was observed in full-thickness defects, but not in partial-thickness defects in rabbit model. Ex vivo and in vitro studies showed that subchondral bone or type 1 collagen (col1) scaffold was more permissive for MSCs adhesion than cartilage or type 2 collagen (col2) scaffold and induced robust stromal cell-derived factors-1 (SDF-1) dependent migration of MSCs. Furthermore, creating a matrix environment with col1 scaffold containing SDF-1 enhanced in situ self-repair of partial-thickness defects in rabbit 6 weeks post-injury. Hence, the inferior self-repair capacity in partial-thickness defects is partially owing to the non-permissive matrix environment. Creating an in situ matrix environment conducive to C-MSCs and SM-MSCs migration and adhesion with col1 scaffold containing SDF-1 can be exploited to improve self-repair capacity of cartilage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. The Effect of Friction Stir Processing on Microstructure and Tensile Behavior of Thixomolded AZ91 Magnesium Alloy

    NASA Astrophysics Data System (ADS)

    Mansoor, B.; Decker, R. F.; Kulkarni, S.; LeBeau, S. E.; Khraisheh, M. K.

    Friction Stir Processing (FSP) to partial sheet thickness can be utilized to engineer unique microstructures in metallic alloys. These composite microstructures consist of three distinct layers associated with stirred, transition and core micro structural regions. The stirred region is of particular interest where severe plastic deformation imparted by the rotating and translating FSP tool under frictional heat leads to grain refinement down to 1 urn grain size. In this work, partial depth penetration into thixomolded AZ91 Mg plate from the top and bottom surfaces by friction stir processing is explored. Furthermore, low temperature aging treatments are applied to the processed material. The present results with AZ91 Mg show that FSP processed material exhibits higher strength (> 300 MPa), and improvement in ductility (> 7 % tensile elongation). It is found that in addition to Hall-Petch strengthening produced by 1 um grain size in the stirred region, the enhanced strength levels and ductility are strongly influenced by dispersoids of the intermetallic precipitates found in this alloy.

  17. Magneto-optical Kerr rotation and color in ultrathin lossy dielectric

    NASA Astrophysics Data System (ADS)

    Zhang, Jing; Wang, Hai; Qu, Xin; Zhou, Yun song; Li, Li na

    2017-05-01

    Ultra-thin optical coating comprising nanometer-thick silicon absorbing films on iron substrates can display strong optical interference effects. A resonance peak of ∼1.6^\\circ longitudinal Kerr rotation with the silicon thickness of ∼47 \\text{nm} was found at the wavelength of 660 nm. The optical properties of silicon thin films were well controlled by the sputtering power. Non-iridescence color exhibition and Kerr rotation enhancement can be manipulated and encoded individually.

  18. Partial repair in irreparable rotator cuff tear: our experience in long-term follow-up.

    PubMed

    Di Benedetto, E D; Di Benedetto, Paolo; Fiocchi, Andrea; Beltrame, Alessandro; Causero, Araldo

    2017-10-18

    Massive rotator cuff tears are a common source of shoulder pain and dysfunction, especially in middle age patient; these lesions represent about 20% of all rotator cuff tears and 80% of recurrent tears. Some lesions are not repairable or should not be repaired: in this case, a rotator cuff partial repair should be recommended. The aim of the study is to evaluate the outcome of rotator cuff partial repair in irreparable rotator cuff massive tear at medium and long-term follow-up. We have evaluated 74 consecutive patients treated with functional repair of rotator cuff by the same surgeon between 2006 and 2014. We divided patients into 2 groups, obtaining 2 average follow-up: at about 6,5 (group A) and 3 years (group B). In December 2015, we evaluated in every patient ROM and Constant Score. We analyzed difference between pre-operatory data and the 2 groups.  Results: We found statistical significant difference in ROM and in Constant Score between pre-operatory data and group A and group B. Between group A and group B there is relevant difference in Constant Score but not in ROM. Partial repair can give good results in a medium follow-up, in terms of pain relief and improvement of ROM, as well as in quality of life. Difference in ROM and Constant Score between group A and group B may indicate the begin of partial repair failure; according to our data, 6-7 years may be the time limit for this surgery technique.

  19. [Shoulder calcifying tendinitis].

    PubMed

    Clavert, P; Sirveaux, F

    2008-12-01

    Calcifying tendinitis is a frequent shoulder disease but the surgical treatment is still debatable. The authors of this symposium reviewed retrospectively 450 patients treated by arthroscopal excision for calcifying tendinitis. Imaging were used to assess the cuff status in every case. The minimum follow-up was five years except for subscapularis and infraspinatus calcification (minimum two years). At the same time, we led a prospective study evaluating the prevalence of the calcifications on 1276 asymptomatic shoulders. The prevalence of rotator cuff calcification was 7.3%, with a female predominance specially in the operated group. Calcifications have been found as well in patients more than 70 years old. The inter- and intraobserver agreement for the A-B-C classification was poor, specially to differentiate the type A and B calcifications. The long-term follow-up allows to prove that the calcifying tendinitis is temporary without any relation with rotator cuff rupture. Recurrence of the calcific deposit after complete disappearance was never observed and the rate of full thickness tears was 3.9% at an average of nine years follow-up (mean age 56 years). These findings allowed to conclude than cuff suture after removing the deposit is not mandatory. However, the preoperative cuff status had a significant influence on the functional results at follow-up. Preoperative associated partial tear of the cuff or a preoperative positive Jobe test affected significantly the results and increased the rate of full thickness tear at follow-up. The subscapularis calcifications were rare (6% of the calcifications) and were associated with further deposit on the cuff. Infraspinatus calcifications were more frequent (20%), mostly associated to over tendons calcifications. The arthroscopic treatment obtained good results independently from the calcification location but the surgical approach should be adapted. Functional results were lower after removing a type C calcification. Acromioplasty improved the results when the calcification was associated with an aggressive acromion or a partial cuff tear.

  20. Control of Transmembrane Helix Dynamics by Interfacial Tryptophan Residues.

    PubMed

    McKay, Matthew J; Martfeld, Ashley N; De Angelis, Anna A; Opella, Stanley J; Greathouse, Denise V; Koeppe, Roger E

    2018-06-05

    Transmembrane protein domains often contain interfacial aromatic residues, which may play a role in the insertion and stability of membrane helices. Residues such as Trp or Tyr, therefore, are often found situated at the lipid-water interface. We have examined the extent to which the precise radial locations of interfacial Trp residues may influence peptide helix orientation and dynamics. To address these questions, we have modified the GW 5,19 ALP23 (acetyl-GGALW 5 (LA) 6 LW 19 LAGA-[ethanol]amide) model peptide framework to relocate the Trp residues. Peptide orientation and dynamics were analyzed by means of solid-state nuclear magnetic resonance (NMR) spectroscopy to monitor specific 2 H- and 15 N-labeled residues. GW 5,19 ALP23 adopts a defined, tilted orientation within lipid bilayer membranes with minimal evidence of motional averaging of NMR observables, such as 2 H quadrupolar or 15 N- 1 H dipolar splittings. Here, we examine how peptide dynamics are impacted by relocating the interfacial Trp (W) residues on both ends and opposing faces of the helix, for example by a 100° rotation on the helical wheel for positions 4 and 20. In contrast to GW 5,19 ALP23, the modified GW 4,20 ALP23 helix experiences more extensive motional averaging of the NMR observables in several lipid bilayers of different thickness. Individual and combined Gaussian analyses of the 2 H and 15 N NMR signals confirm that the extent of dynamic averaging, particularly rotational "slippage" about the helix axis, is strongly coupled to the radial distribution of the interfacial Trp residues as well as the bilayer thickness. Additional 2 H labels on alanines A3 and A21 reveal partial fraying of the helix ends. Even within the context of partial unwinding, the locations of particular Trp residues around the helix axis are prominent factors for determining transmembrane helix orientation and dynamics within the lipid membrane environment. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  1. Diagnostic accuracy of ultrasonography, MRI and MR arthrography in the characterisation of rotator cuff disorders: a systematic review and meta-analysis

    PubMed Central

    Roy, Jean-Sébastien; Braën, Caroline; Leblond, Jean; Desmeules, François; Dionne, Clermont E; MacDermid, Joy C; Bureau, Nathalie J; Frémont, Pierre

    2015-01-01

    Background Different diagnostic imaging modalities, such as ultrasonography (US), MRI, MR arthrography (MRA) are commonly used for the characterisation of rotator cuff (RC) disorders. Since the most recent systematic reviews on medical imaging, multiple diagnostic studies have been published, most using more advanced technological characteristics. The first objective was to perform a meta-analysis on the diagnostic accuracy of medical imaging for characterisation of RC disorders. Since US is used at the point of care in environments such as sports medicine, a secondary analysis assessed accuracy by radiologists and non-radiologists. Methods A systematic search in three databases was conducted. Two raters performed data extraction and evaluation of risk of bias independently, and agreement was achieved by consensus. Hierarchical summary receiver-operating characteristic package was used to calculate pooled estimates of included diagnostic studies. Results Diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears was high with overall estimates of sensitivity and specificity over 0.90. As for partial RC tears and tendinopathy, overall estimates of specificity were also high (>0.90), while sensitivity was lower (0.67–0.83). Diagnostic accuracy of US was similar whether a trained radiologist, sonographer or orthopaedist performed it. Conclusions Our results show the diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears. Since full thickness tear constitutes a key consideration for surgical repair, this is an important characteristic when selecting an imaging modality for RC disorder. When considering accuracy, cost, and safety, US is the best option. PMID:25677796

  2. Risk Factor Analysis of Freestyle Propeller Flaps.

    PubMed

    Paik, Joo Myong; Pyon, Jai-Kyong

    2017-01-01

    Background  Freestyle propeller flaps have been widely used as a reconstructive option for both trunk and extremities. It offers the advantage of "like-with-like" reconstruction with an adjacent tissue with no dissection to the source vessels. However, there is the risk of vascular complications. In the present study, the authors investigated the incidence of vascular complications and their risk factors following freestyle propeller flap in the trunk and extremities. Methods  The authors conducted a retrospective review of 50 patients who underwent soft tissue reconstruction of the trunk and the extremities with 55 freestyle propeller flaps from 2004 to 2015. Data regarding patient demographics, surgical details, including the arc of rotation, and flap complications were collected from a prospectively maintained database and analyzed. Results  There were 10 flap complications (18.2%), including 7 superficial partial necrosis, 2 full-thickness partial necrosis, and 1 total necrosis from the 55 freestyle propeller flaps harvested. Previous irradiation was a significant risk factor for flap complications and the propeller flap harvested from the extremities showed a significantly higher rate of complications compared with those harvested from the trunk. Complication rates were higher in flaps with the arc of rotation between 150 and 180 degrees with marginal significance compared with flaps with the arc of rotation less than 150 degrees. Conclusions  Freestyle propeller flaps proved to be a valid and reliable option for reconstruction of defects in the trunk, while complication rate was quite high in the extremities. A prudent preoperative evaluation and preparation may be necessary before performing this surgical technique in the extremities. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. The effects of film thickness on the electrical, optical, and structural properties of cylindrical, rotating, magnetron-sputtered ITO films

    NASA Astrophysics Data System (ADS)

    Kim, Jae-Ho; Seong, Tae-Yeon; Ahn, Kyung-Jun; Chung, Kwun-Bum; Seok, Hae-Jun; Seo, Hyeong-Jin; Kim, Han-Ki

    2018-05-01

    We report the characteristics of Sn-doped In2O3 (ITO) films intended for use as transparent conducting electrodes; the films were prepared via a five-generation, in-line type, cylindrical, rotating magnetron sputtering (CRMS) system as a function of film thickness. By using a rotating cylindrical ITO target with high usage (∼80%), we prepared high conductivity, transparent ITO films on five-generation size glass. The effects of film thickness on the electrical, optical, morphological, and structural properties of CRMS-grown ITO films are investigated in detail to correlate the thickness and performance of ITO films. The preferred orientation changed from the (2 2 2) to the (4 0 0) plane with increasing thickness of ITO is attributed to the stability of the (4 0 0) plane against resputtering during the CRMS process. Based on X-ray diffraction, surface field emission scanning electron microscopy, and cross-sectional transmission electron microscopy, we suggest a possible mechanism to explain the preferred orientation and effects of film thickness on the performance of CRMS-grown ITO films.

  4. Method and apparatus for ultrasonic characterization through the thickness direction of a moving web

    DOEpatents

    Jackson, Theodore; Hall, Maclin S.

    2001-01-01

    A method and apparatus for determining the caliper and/or the ultrasonic transit time through the thickness direction of a moving web of material using ultrasonic pulses generated by a rotatable wheel ultrasound apparatus. The apparatus includes a first liquid-filled tire and either a second liquid-filled tire forming a nip or a rotatable cylinder that supports a thin moving web of material such as a moving web of paper and forms a nip with the first liquid-filled tire. The components of ultrasonic transit time through the tires and fluid held within the tires may be resolved and separately employed to determine the separate contributions of the two tire thicknesses and the two fluid paths to the total path length that lies between two ultrasonic transducer surfaces contained within the tires in support of caliper measurements. The present invention provides the benefit of obtaining a transit time and caliper measurement at any point in time as a specimen passes through the nip of rotating tires and eliminates inaccuracies arising from nonuniform tire circumferential thickness by accurately retaining point-to-point specimen transit time and caliper variation information, rather than an average obtained through one or more tire rotations. Morever, ultrasonic transit time through the thickness direction of a moving web may be determined independent of small variations in the wheel axle spacing, tire thickness, and liquid and tire temperatures.

  5. Contribution of calcaneal and leg segment rotations to ankle joint dorsiflexion in a weight-bearing task.

    PubMed

    Chizewski, Michael G; Chiu, Loren Z F

    2012-05-01

    Joint angle is the relative rotation between two segments where one is a reference and assumed to be non-moving. However, rotation of the reference segment will influence the system's spatial orientation and joint angle. The purpose of this investigation was to determine the contribution of leg and calcaneal rotations to ankle rotation in a weight-bearing task. Forty-eight individuals performed partial squats recorded using a 3D motion capture system. Markers on the calcaneus and leg were used to model leg and calcaneal segment, and ankle joint rotations. Multiple linear regression was used to determine the contribution of leg and calcaneal segment rotations to ankle joint dorsiflexion. Regression models for left (R(2)=0.97) and right (R(2)=0.97) ankle dorsiflexion were significant. Sagittal plane leg rotation had a positive influence (left: β=1.411; right: β=1.418) while sagittal plane calcaneal rotation had a negative influence (left: β=-0.573; right: β=-0.650) on ankle dorsiflexion. Sagittal plane rotations of the leg and calcaneus were positively correlated (left: r=0.84, P<0.001; right: r=0.80, P<0.001). During a partial squat, the calcaneus rotates forward. Simultaneous forward calcaneal rotation with ankle dorsiflexion reduces total ankle dorsiflexion angle. Rear foot posture is reoriented during a partial squat, allowing greater leg rotation in the sagittal plane. Segment rotations may provide greater insight into movement mechanics that cannot be explained via joint rotations alone. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Automated pharmaceutical tablet coating layer evaluation of optical coherence tomography images

    NASA Astrophysics Data System (ADS)

    Markl, Daniel; Hannesschläger, Günther; Sacher, Stephan; Leitner, Michael; Khinast, Johannes G.; Buchsbaum, Andreas

    2015-03-01

    Film coating of pharmaceutical tablets is often applied to influence the drug release behaviour. The coating characteristics such as thickness and uniformity are critical quality parameters, which need to be precisely controlled. Optical coherence tomography (OCT) shows not only high potential for off-line quality control of film-coated tablets but also for in-line monitoring of coating processes. However, an in-line quality control tool must be able to determine coating thickness measurements automatically and in real-time. This study proposes an automatic thickness evaluation algorithm for bi-convex tables, which provides about 1000 thickness measurements within 1 s. Beside the segmentation of the coating layer, optical distortions due to refraction of the beam by the air/coating interface are corrected. Moreover, during in-line monitoring the tablets might be in oblique orientation, which needs to be considered in the algorithm design. Experiments were conducted where the tablet was rotated to specified angles. Manual and automatic thickness measurements were compared for varying coating thicknesses, angles of rotations, and beam displacements (i.e. lateral displacement between successive depth scans). The automatic thickness determination algorithm provides highly accurate results up to an angle of rotation of 30°. The computation time was reduced to 0.53 s for 700 thickness measurements by introducing feasibility constraints in the algorithm.

  7. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    PubMed Central

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment. PMID:28900553

  8. Tempest in a glass tube: A helical vortex formation in a complex plasma

    NASA Astrophysics Data System (ADS)

    Saitou, Yoshifumi; Ishihara, Osamu; Ishihara

    2014-12-01

    A collective behavior of dust particles in a complex plasma with a magnetic field (up to 4 kG) is investigated. Dust particles form a dust disk which is rotating in a horizontal plane pushed by ions rotating with the E × B drift as a trigger force. The thickness of the disk is determined by controlling the experimental conditions. The disk rotates in a horizontal plane and forms a two-dimensional thin structure when the pressure pAr is relatively high. The dust particles are ejected from near the disk center and form a rotation in the vertical plane and, hence, forms a helical vortex when the disk is thick for relatively low pAr . The reason the dust disk has the different thickness is due to the neutral pressure. Under a higher (lower) neutral gas pressure, the disk becomes two (three) dimensional due to the influence of the neutral drag force.

  9. A semi-analytical solution for elastic analysis of rotating thick cylindrical shells with variable thickness using disk form multilayers.

    PubMed

    Zamani Nejad, Mohammad; Jabbari, Mehdi; Ghannad, Mehdi

    2014-01-01

    Using disk form multilayers, a semi-analytical solution has been derived for determination of displacements and stresses in a rotating cylindrical shell with variable thickness under uniform pressure. The thick cylinder is divided into disk form layers form with their thickness corresponding to the thickness of the cylinder. Due to the existence of shear stress in the thick cylindrical shell with variable thickness, the equations governing disk layers are obtained based on first-order shear deformation theory (FSDT). These equations are in the form of a set of general differential equations. Given that the cylinder is divided into n disks, n sets of differential equations are obtained. The solution of this set of equations, applying the boundary conditions and continuity conditions between the layers, yields displacements and stresses. A numerical solution using finite element method (FEM) is also presented and good agreement was found.

  10. A Semi-Analytical Solution for Elastic Analysis of Rotating Thick Cylindrical Shells with Variable Thickness Using Disk Form Multilayers

    PubMed Central

    Zamani Nejad, Mohammad; Jabbari, Mehdi; Ghannad, Mehdi

    2014-01-01

    Using disk form multilayers, a semi-analytical solution has been derived for determination of displacements and stresses in a rotating cylindrical shell with variable thickness under uniform pressure. The thick cylinder is divided into disk form layers form with their thickness corresponding to the thickness of the cylinder. Due to the existence of shear stress in the thick cylindrical shell with variable thickness, the equations governing disk layers are obtained based on first-order shear deformation theory (FSDT). These equations are in the form of a set of general differential equations. Given that the cylinder is divided into n disks, n sets of differential equations are obtained. The solution of this set of equations, applying the boundary conditions and continuity conditions between the layers, yields displacements and stresses. A numerical solution using finite element method (FEM) is also presented and good agreement was found. PMID:24719582

  11. Increased supraspinatus tendon thickness following fatigue loading in rotator cuff tendinopathy: potential implications for exercise therapy.

    PubMed

    McCreesh, Karen M; Purtill, Helen; Donnelly, Alan E; Lewis, Jeremy S

    2017-01-01

    Exercise imparts a load on tendon tissue that leads to changes in tendon properties. Studies suggest that loading immediately reduces tendon thickness, with a loss of this response in symptomatic tendinopathy. No studies investigating the response of tendon dimensions to load for the rotator cuff tendons exist. This study aimed to examine the short-term effect of loading on the thickness of the supraspinatus tendon and acromiohumeral distance those with and without rotator cuff tendinopathy. Participants were 20 painfree controls, and 23 people with painful rotator cuff tendinopathy. Supraspinatus tendon thickness and acromiohumeral distance were measured using ultrasound scans before, and at three time points after loading (1, 6 and 24 hours). Loading involved isokinetic eccentric and concentric external rotation and abduction. There was a significant increase in supraspinatus tendon thickness in the pain group at 1 (7%, ∆=0.38, 95% CI 0.19 to 0.57) and 6 hours (11%, ∆=0.53, 95% CI 0.34 to 0.71), although only the 6 hours difference exceeded minimal detectable difference. In contrast, there was a small non-significant reduction in thickness in controls. The acromiohumeral distance reduced significantly in both groups at 1 hour (controls: ∆=0.64, 95% CI 0.38 to 0.90; pain: ∆=1.1, 95% CI 0.85 to 1.33), with a larger change from baseline in the pain group. Those diagnosed with painful supraspinatus tendinopathy demonstrated increased thickening with delayed return to baseline following loading. Rehabilitation professionals may need to take into account the impact of loading to fatigue when planning rehabilitation programmes.

  12. Increased supraspinatus tendon thickness following fatigue loading in rotator cuff tendinopathy: potential implications for exercise therapy

    PubMed Central

    McCreesh, Karen M; Purtill, Helen; Donnelly, Alan E; Lewis, Jeremy S

    2017-01-01

    Background/aim Exercise imparts a load on tendon tissue that leads to changes in tendon properties. Studies suggest that loading immediately reduces tendon thickness, with a loss of this response in symptomatic tendinopathy. No studies investigating the response of tendon dimensions to load for the rotator cuff tendons exist. This study aimed to examine the short-term effect of loading on the thickness of the supraspinatus tendon and acromiohumeral distance those with and without rotator cuff tendinopathy. Methods Participants were 20 painfree controls, and 23 people with painful rotator cuff tendinopathy. Supraspinatus tendon thickness and acromiohumeral distance were measured using ultrasound scans before, and at three time points after loading (1, 6 and 24 hours). Loading involved isokinetic eccentric and concentric external rotation and abduction. Results There was a significant increase in supraspinatus tendon thickness in the pain group at 1 (7%, ∆=0.38, 95% CI 0.19 to 0.57) and 6 hours (11%, ∆=0.53, 95% CI 0.34 to 0.71), although only the 6 hours difference exceeded minimal detectable difference. In contrast, there was a small non-significant reduction in thickness in controls. The acromiohumeral distance reduced significantly in both groups at 1 hour (controls: ∆=0.64, 95% CI 0.38 to 0.90; pain: ∆=1.1, 95% CI 0.85 to 1.33), with a larger change from baseline in the pain group. Conclusion Those diagnosed with painful supraspinatus tendinopathy demonstrated increased thickening with delayed return to baseline following loading. Rehabilitation professionals may need to take into account the impact of loading to fatigue when planning rehabilitation programmes. PMID:29333279

  13. Angular shear plate

    DOEpatents

    Ruda, Mitchell C [Tucson, AZ; Greynolds, Alan W [Tucson, AZ; Stuhlinger, Tilman W [Tucson, AZ

    2009-07-14

    One or more disc-shaped angular shear plates each include a region thereon having a thickness that varies with a nonlinear function. For the case of two such shear plates, they are positioned in a facing relationship and rotated relative to each other. Light passing through the variable thickness regions in the angular plates is refracted. By properly timing the relative rotation of the plates and by the use of an appropriate polynomial function for the thickness of the shear plate, light passing therethrough can be focused at variable positions.

  14. The relationship between age, rotator cuff integrity, and osseous microarchitecture of greater tuberosity: Where should we put anchor?

    PubMed

    Kholinne, Erica; Lee, Hyun Joo; Kim, Sung Jung; Park, So Hyun; Jeon, In-Ho

    2018-01-01

    The aim of this study was to compare the microarchitecture of the greater tuberosity with or without rotator cuff tear and to obtain optimum location for anchor screw insertion for rotator cuff repair. Twenty-five humeral heads were harvested from 13 male cadavers of mean age 58.4 years, including 6 humeri with rotator cuff tear and 19 intact humeri. Six regions of interest (proximal, intermediate, and distal zones of the superficial and deep regions) were divided into the anterior (G1), middle (G2), and posterior (G3) areas of the greater tuberosity. Trabecular bone volume and cortical thickness were evaluated. Total trabecular bone volume was greater in subjects <50 years old than in subjects >50 years old but did not differ significantly in subjects with and without rotator cuff tear. Cortical thickness in both intact and torn rotator cuff groups was significantly greater in the proximal and intermediate zones than in the distal zone. Cortical thickness was related to anatomic location rather than age or cuff tear. The optimal location for anchor screw insertion during rotator cuff repair is either the proximal or intermediate region of the greater tuberosity. Age has more influence in terms of trabecular bone volume loss than rotator cuff integrity. Copyright © 2017. Production and hosting by Elsevier B.V.

  15. Quantitative assessment of fatty infiltration and muscle volume of the rotator cuff muscles using 3-dimensional 2-point Dixon magnetic resonance imaging.

    PubMed

    Matsumura, Noboru; Oguro, Sota; Okuda, Shigeo; Jinzaki, Masahiro; Matsumoto, Morio; Nakamura, Masaya; Nagura, Takeo

    2017-10-01

    In patients with rotator cuff tears, muscle degeneration is known to be a predictor of irreparable tears and poor outcomes after surgical repair. Fatty infiltration and volume of the whole muscles constituting the rotator cuff were quantitatively assessed using 3-dimensional 2-point Dixon magnetic resonance imaging. Ten shoulders with a partial-thickness tear, 10 shoulders with an isolated supraspinatus tear, and 10 shoulders with a massive tear involving supraspinatus and infraspinatus were compared with 10 control shoulders after matching age and sex. With segmentation of muscle boundaries, the fat fraction value and the volume of the whole rotator cuff muscles were computed. After reliabilities were determined, differences in fat fraction, muscle volume, and fat-free muscle volume were evaluated. Intra-rater and inter-rater reliabilities were regarded as excellent for fat fraction and muscle volume. Tendon rupture adversely increased the fat fraction value of the respective rotator cuff muscle (P < .002). In the massive tear group, muscle volume was significantly decreased in the infraspinatus (P = .035) and increased in the teres minor (P = .039). With subtraction of fat volume, a significant decrease of fat-free volume of the supraspinatus muscle became apparent with a massive tear (P = .003). Three-dimensional measurement could evaluate fatty infiltration and muscular volume with excellent reliabilities. The present study showed that chronic rupture of the tendon adversely increases the fat fraction of the respective muscle and indicates that the residual capacity of the rotator cuff muscles might be overestimated in patients with severe fatty infiltration. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Vibration and buckling of rotating, pretwisted, preconed beams including Coriolis effects

    NASA Technical Reports Server (NTRS)

    Subrahmanyam, K. B.; Kaza, K. R. V.

    1985-01-01

    The effects of pretwist, precone, setting angle and Coriolis forces on the vibration and buckling behavior of rotating, torsionally rigid, cantilevered beams were studied. The beam is considered to be clamped on the axis of rotation in one case, and off the axis of rotation in the other. Two methods are employed for the solution of the vibration problem: (1) one based upon a finite-difference approach using second order central differences for solution of the equations of motion, and (2) based upon the minimum of the total potential energy functional with a Ritz type of solution procedure making use of complex forms of shape functions for the dependent variables. The individual and collective effects of pretwist, precone, setting angle, thickness ratio and Coriolis forces on the natural frequencies and the buckling boundaries are presented. It is shown that the inclusion of Coriolis effects is necessary for blades of moderate to large thickness ratios while these effects are not so important for small thickness ratio blades. The possibility of buckling due to centrifugal softening terms for large values of precone and rotation is shown.

  17. Vibration and buckling of rotating, pretwisted, preconed beams including Cooriolis effects

    NASA Technical Reports Server (NTRS)

    Subrahmanyam, K. B.; Kaza, K. R. V.

    1985-01-01

    The effects of pretwist, precone, setting angle and Coriolis forces on the vibration and buckling behavior of rotating, torsionally rigid, cantilevered beams were studied. The beam is considered to be clamped on the axis of rotation in one case, and off the axis of rotation in the other. Two methods are employed for the solution of the vibration problem: (1) one based upon a finite-difference approach using second order central differences for solution of the equations of motion, and (2) based upon the minimum of the total potential energy functional with a Ritz type of solution procedure making use of complex forms of shape functions for the dependent variables. The individual and collective effects of pretwist, precone, setting angle, thickness ratio and Coriolis forces on the natural frequencies and the buckling boundaries are presented. It is shown that the inclusion of Coriolis effects is necessary for blades of moderate to large thickness ratios while these effects are not so important for small thickness ratio blades. The possibility of buckling due to centrifugal softening terms for large values of precone and rotation is shown.

  18. The prevalence of rotator cuff tears: is the contralateral shoulder at risk?

    PubMed

    Liem, Dennis; Buschmann, Vera Elisa; Schmidt, Carolin; Gosheger, Georg; Vogler, Tim; Schulte, Tobias L; Balke, Maurice

    2014-04-01

    Rotator cuff tears are a common cause of pain and disability of the shoulder. Information on the prevalence and identification of potential risk factors could help in early detection of rotator cuff tears and improve treatment outcome. Patients treated for a symptomatic rotator cuff tear on one side have a higher prevalence of rotator cuff tears and decreased shoulder function on the contralateral side compared with an age- and sex-matched group of healthy individuals. Case control study; Level of evidence, 3. One group consisted of 55 patients who had been arthroscopically treated on one shoulder for rotator cuff tear (tear group). In this group, the nonoperated contralateral shoulder was examined. For comparison, the matching shoulder in a control group consisting of 55 subjectively healthy individuals matched by age (±1 year) and sex to the tear group was included. Diagnosis of a rotator cuff tear was made by ultrasound. Outcomes were measured using the Constant score. The prevalence of supraspinatus tears was significantly higher (P < .0001) in the tear group (67.3%) compared with the control group (11.0%). The Constant score for the activities of daily living subscale, however, was significantly lower (18.4) in the tear group compared with the control group (19.9; P = .012). No other subcategory score nor the overall score showed a significant difference. There was a significantly higher tear prevalence in the tear group of patients aged between 50 and 59 years (P < .001) and 60 and 69 years (P = .004). No tear was diagnosed in the control group in individuals younger than 60 years. Patients treated for partial and full-thickness rotator cuff tears have a significantly higher risk of having a tear on the contralateral side and have noticeable deficits in their shoulder function regarding activities of daily living even if the tear is otherwise asymptomatic.

  19. [Clinical study and pathological examination on the treatment of deep partial thickness burn wound with negative charge aerosol].

    PubMed

    Li, Tian-zeng; Xu, Ying-bin; Hu, Xiao-gen; Shen, Rui; Peng, Xiao-dong; Wu, Wei-jiang; Luo, Lan; Dai, Xin-ming; Zou, Yong-tong; Qi, Shao-hai; Wu, Li-ping; Xie, Ju-lin; Deng, Xiao-xin; Chen, E; Zhang, Hui-Zhen

    2005-08-01

    To investigate the effect of negative charge aerosol (NCA) on the treatment of burn wound. Patients with superficial or deep partial thickness burn only were enrolled in the study, and they were randomly divided into trial group (T, including 180 cases of superficial thickness burn and 100 cases of deep partial thickness burn), control group (C, including 30 cases with superficial thickness burn and 30 with deep partial thickness burn), and self control group (SC, including 10 cases with superficial thickness burn and 10 with deep partial thickness burn). The patients in T and SC groups were treated with NCA for 1.5 hours, 1-2 times a day, from 6 postburn hour (PBH) to 2 postburn day (PBD), while those in C group received conventional treatment. For those in SC group, some of the wounds were covered with sterile schissel, while other wounds without schissel covering. The general changes in the wounds during NCA treatment were observed, and bacterial culture before and after NCA treatment was performed. The healing time was recorded and the blood biochemical parameters were determined. Rat model with deep partial thickness scald was established, and the rats were also divided into T and C groups, and received treatment as in human. Tissue samples were harvested from the wounds of rats in the 2 groups before and 1, 2, 3 weeks after treatment for pathological examination. There was no infection and little exudation in the patients in T group. No bacteria were found in the wound before and after NCA treatment. The healing time of the wounds of patients with superficial and deep partial thickness burn in T group was 6.3 +/- 1.6 d and 15.1 +/- 3.1 d, respectively, which was obviously shorter than those in C group (11.3 +/- 1.4 d and 21.2 +/- 1.4 d, P < 0.01). In SC group, the healing time of those with sterile schissel coverage was also significantly shorter than those without covering (P < 0.01). There was no obvious change in the liver and kidney functions and blood biochemical parameters among the patients. Pathological examination showed that the skin structure was almost recovered in the rats in T group 3 weeks after treatment, while those in C group was not. Negative charge aerosol is safe and effective in promoting wound healing of the patients with partial thickness burns.

  20. Effect of rotation on gravitational instability of optically thick magnetized quantum plasma in the presence of radiation

    NASA Astrophysics Data System (ADS)

    Kumar, A.; Pensia, R. K.

    2018-05-01

    This paper deals with the effect of rotation on the gravitational instability of optically thick magnetized quantum plasma in the presence of radiation. By using linearized perturbation equations of the problem, general dispersion relation is obtained which is reduced for longitudinal and transverse modes of propagation. For each mode, the problem is analyzed for two cases, when the direction of axis of rotation is parallel or perpendicular to the direction of magnetic field. Rotation parameter is found to modify the Jeans criterion of instability and expression for Jeans wavelength for transverse mode, when the axis of rotation is along the direction of magnetic field and it has stabilizing effect on the system. Magnetic field, radiation pressure and quantum correction also found to have stabilizing effect.

  1. The role of alternative therapy in the management of partial thickness burns of the face--experience with the use of moist exposed burn ointment (MEBO) compared with silver sulphadiazine.

    PubMed

    Ang, E S; Lee, S T; Gan, C S; See, P; Chan, Y H; Ng, L H; Machin, D

    2000-01-01

    Conventional management of partial thickness facial burn wounds includes the use of silver sulphadiazine dressings. Silver sulphadiazine forms an overlying slough that makes wound healing assessment difficult. Moist exposed burn ointment (MEBO) has been proposed as the ideal burn wound dressing both for burns of the face and other sites. Proponents of MEBO claim that it accelerates wound healing and results in scarless wound healing and at the same time reduce bacterial colonisation and the need for analgesics. We present here our experience with MEBO in the management of partial thickness burns of the face. One hundred and fifteen patients with partial thickness burns were randomly assigned to conventional treatment or MEBO. Out of this, 112 were analysed. Thirty-nine patients sustained facial burns; 17 received MEBO and 22 received silver sulphadiazine. Patients were followed up daily until the burn wounds were reduced by 75% of original body surface area (BSA). In patients with facial burns, MEBO was similar to silver sulphadiazine therapy with respect to rate of wound healing. Minimal slough was present over the wounds in MEBO-treated wounds resulting in clearer assessment of healing progression. Advantages of MEBO as compared to silver sulphadiazine in the management of partial thickness burns of the face include convenient change of dressing and easier assessment of healing progression. This suggests that MEBO is a useful alternative therapy for partial thickness burns of the face.

  2. New Optical Field Generated by Partial Tracing Over Two-Mode Squeezing-Rotating Entangled Vacuum State ^{{*}}

    NASA Astrophysics Data System (ADS)

    Ren, Gang; Du, Jian-ming; Zhang, Wen-Hai

    2018-05-01

    Based on the two-mode squeezing-rotating entangled vacuum state (Fan and Fan in Commun Theor Phys 33:701-704, 2000), we obtained a new quantum state by using partial tracing method. This new state can be considered as a real chaotic field. We also studied its squeezing properties and quantum statistical properties by giving the analytic results and exact numerical results. It was established that the rotation angle's parameter plays an important role in this new optical field.

  3. Mapping the Asymmetric Thick Disk. III. The Kinematics and Interaction with the Galactic Bar

    NASA Astrophysics Data System (ADS)

    Humphreys, Roberta M.; Beers, Timothy C.; Cabanela, Juan E.; Grammer, Skyler; Davidson, Kris; Lee, Young Sun; Larsen, Jeffrey A.

    2011-04-01

    In the first two papers of this series, Larsen et al. describe our faint CCD survey in the inner Galaxy and map the overdensity of thick disk stars in Quadrant 1 (Q1) to 5 kpc or more along the line of sight. The regions showing the strongest excess are above the density contours of the bar in the Galactic disk. In this third paper on the asymmetric thick disk, we report on radial velocities and derived metallicity parameters for over 4000 stars in Q1, above and below the plane, and in Quadrant 4 (Q4) above the plane. We confirm the corresponding kinematic asymmetry first reported by Parker et al., extended to greater distances and with more spatial coverage. The thick disk stars in Q1 have a rotational lag of 60-70 km s-1 relative to circular rotation, and the metal-weak thick disk stars have an even greater lag of 100 km s-1. Both lag their corresponding populations in Q4 by ≈30 km s-1. Interestingly, the disk stars in Q1 also appear to participate in the rotational lag by about 30 km s-1. The enhanced rotational lag for the thick disk in Q1 extends to 4 kpc or more from the Sun. At 3-4 kpc, our sight lines extend above the density contours on the near side of the bar, and as our lines of sight pass directly over the bar the rotational lag appears to decrease. This is consistent with a "gravitational wake" induced by the rotating bar in the disk which would trap and pile up stars behind it. We conclude that a dynamical interaction with the stellar bar is the most probable explanation for the observed kinematic and spatial asymmetries. Based on observations obtained at the MMT Observatory, a joint facility of the Smithsonian Institution and the University of Arizona, and at the Cerro Tololo Inter-American Observatory (NOAO) operated by the Association of Universities for Research in Astronomy (AURA).

  4. Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography.

    PubMed

    Amano, Shiro; Honda, Norihiko; Amano, Yuki; Yamagami, Satoru; Miyai, Takashi; Samejima, Tomokazu; Ogata, Miyuki; Miyata, Kazunori

    2006-06-01

    To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. Experimental study. Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5 subjects, and the intraexaminer repeatability was assessed as the absolute difference of the first and second measurements. Two experienced examiners took one measurement for each pachymetry in another 10 eyes of 5 subjects, and the interexaminer reproducibility was assessed as the absolute difference of the 2 measurements of the first and second examiners. Central corneal thickness measurements by the 3 methods, absolute difference of the first and second measurements by a single examiner, absolute difference of the 2 measurements by 2 examiners, and relative amount of variation. The average measurements of central corneal thickness by a rotating Scheimpflug camera, scanning-slit topography, and ultrasonic pachymetry were 538+/-31.3 microm, 541+/-40.7 microm, and 545+/-31.3 microm, respectively. There were no statistically significant differences in the measurement results among the 3 methods (P = 0.569, repeated-measures analysis of variance). There was a significant linear correlation between the rotating Scheimpflug camera and ultrasonic pachymetry (r = 0.908, P<0.0001), rotating Scheimpflug camera and scanning-slit topography (r = 0.930, P<0.0001), and ultrasonic pachymetry and scanning-slit topography (r = 0.887, P<0.0001). Ultrasonic pachymetry had the smallest intraexaminer variability, and scanning-slit topography had the largest intraexaminer variability among the 3 methods. There were similar variations in interexaminer reproducibility among the 3 methods. Mean corneal thicknesses were comparable among rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit topography with the acoustic equivalent correction factor. The measurements of the 3 instruments had significant linear correlations with one another, and all methods had highly satisfactory measurement repeatability.

  5. Medial collateral ligament injuries and subsequent load on the anterior cruciate ligament: a biomechanical evaluation in a cadaveric model.

    PubMed

    Battaglia, Michael J; Lenhoff, Mark W; Ehteshami, John R; Lyman, Stephen; Provencher, Matthew T; Wickiewicz, Thomas L; Warren, Russell F

    2009-02-01

    Numerous studies have documented the effect of complete medial collateral ligament injury on anterior cruciate ligament loads; few have addressed how partial medial collateral ligament disruption affects knee kinematics. To determine knee kinematics and subsequent change in anterior cruciate ligament load in a partial and complete medial collateral ligament injury model. Controlled laboratory study. Ten human cadaveric knees were sequentially tested by a robot with the medial collateral ligament intact, in a partial injury model, and in a complete injury model with a universal force-moment sensor measuring system. Tibial translation, rotation, and anterior cruciate ligament load were measured under 3 conditions: anterior load (125 N), valgus load (10 N x m), and internal-external rotation torque (4 N x m; all at 0 degrees and 30 degrees of flexion). Anterior and posterior translation did not statistically increase with a partial or complete medial collateral ligament injury at 0 degrees and 30 degrees of flexion. In response to a 125 N anterior load, at 0 degrees , the anterior cruciate ligament load increased 8.7% (from 99.5 to 108.2 N; P = .006) in the partial injury and 18.3% (117.7 N; P < .001) in the complete injury; at 30 degrees , anterior cruciate ligament load was increased 12.3% (from 101.7 to 114.2 N; P = .001) in the partial injury and 20.6% (122.7 N; P < .001) in the complete injury. In response to valgus torque (10 N x m) at 30 degrees , anterior cruciate ligament load was increased 55.3% (30.4 to 47.2 N; P = .044) in the partial injury model and 185% (86.8 N; P = .001) in the complete injury model. In response to internal rotation torque (4 N.m) at 30 degrees , anterior cruciate ligament load was increased 29.3% (27.6 to 35.7 N; P = .001) in the partial injury model and 65.2% (45.6 N; P < .001) in the complete injury model. The amount of internal rotation at 30 degrees of flexion was significantly increased in the complete injury model (22.8 degrees ) versus the intact state (19.5 degrees ; P < .001). Partial and complete medial collateral ligament tears significantly increased the load on the anterior cruciate ligament. In a partial tear, the resultant load on the anterior cruciate ligament was increased at 30 degrees of flexion and with valgus load and internal rotation torque. Patients may need to be protected from valgus and internal rotation forces after anterior cruciate ligament reconstruction in the setting of a concomitant partial medial collateral ligament tear. This information may help clinicians understand the importance of partial injuries of the medial collateral ligament with a combined anterior cruciate ligament injury complex.

  6. Diagnostic power of optic disc morphology, peripapillary retinal nerve fiber layer thickness, and macular inner retinal layer thickness in glaucoma diagnosis with fourier-domain optical coherence tomography.

    PubMed

    Huang, Jehn-Yu; Pekmezci, Melike; Mesiwala, Nisreen; Kao, Andrew; Lin, Shan

    2011-02-01

    To evaluate the capability of the optic disc, peripapillary retinal nerve fiber layer (P-RNFL), macular inner retinal layer (M-IRL) parameters, and their combination obtained by Fourier-domain optical coherent tomography (OCT) in differentiating a glaucoma suspect from perimetric glaucoma. Two hundred and twenty eyes from 220 patients were enrolled in this study. The optic disc morphology, P-RNFL, and M-IRL were assessed by the Fourier-domain OCT (RTVue OCT, Model RT100, Optovue, Fremont, CA). A linear discriminant function was generated by stepwise linear discriminant analysis on the basis of OCT parameters and demographic factors. The diagnostic power of these parameters was evaluated with receiver operating characteristic (ROC) curve analysis. The diagnostic power in the clinically relevant range (specificity ≥ 80%) was presented as the partial area under the ROC curve (partial AROC). The individual OCT parameter with the largest AROC and partial AROC in the high specificity (≥ 80%) range were cup/disc vertical ratio (AROC = 0.854 and partial AROC = 0.142) for the optic disc parameters, average thickness (AROC = 0.919 and partial AROC = 0.147) for P-RNFL parameters, inferior hemisphere thickness (AROC = 0.871 and partial AROC = 0.138) for M-IRL parameters, respectively. The linear discriminant function further enhanced the ability in detecting perimetric glaucoma (AROC = 0.970 and partial AROC = 0.172). Average P-RNFL thickness is the optimal individual OCT parameter to detect perimetric glaucoma. Simultaneous evaluation on disc morphology, P-RNFL, and M-IRL thickness can improve the diagnostic accuracy in diagnosing glaucoma.

  7. Validity of GNRB® arthrometer compared to Telos™ in the assessment of partial anterior cruciate ligament tears.

    PubMed

    Lefevre, N; Bohu, Y; Naouri, J F; Klouche, S; Herman, S

    2014-02-01

    The main goal of this study was to compare the results of the GNRB(®) arthrometer to those of Telos™ in the diagnosis of partial thickness tears of the anterior cruciate ligament (ACL). A prospective study performed January-December 2011 included all patients presenting with a partial or full-thickness ACL tears without ACL reconstruction and with a healthy contralateral knee. Anterior laxity was measured in all patients by the Telos™ and GNRB(®) devices. This series included 139 patients, mean age 30.7 ± 9.3 years. Arthroscopic reconstruction was performed in 109 patients, 97 for complete tears and 12 single bundle reconstructions for partial thickness tears. Conservative treatment was proposed in 30 patients with a partial thickness tear. The correlation between the two devices was evaluated by the Spearman coefficient. The optimal laxity thresholds were determined with ROC curves, and the diagnostic value of the tests was assessed by the area under the curve (AUC). The differential laxities of full and partial thickness tears were significantly different with the two tests. The correlation between the results of laxity measurement with the two devices was fair, with the strongest correlation between Telos™ 250 N and GNRB(®) 250 N (r = 0.46, p = 0.00001). Evaluation of the AUC showed that the informative value of all tests was fair with the best results with the GNRB(®) 250 N: AUC = 0.89 [95 % CI 0.83-0.94]. The optimal differential laxity threshold with the GNRB(®) 250 N was 2.5 mm (Se = 84 %, Sp = 81 %). The diagnostic value of GNRB(®) was better than Telos™ for ACL partial thickness tears.

  8. A process for providing positive primary control power by wind turbines

    NASA Astrophysics Data System (ADS)

    Marschner, V.; Michael, J.; Liersch, J.

    2014-12-01

    Due to the increasing share of wind energy in electricity generation, wind turbines have to fulfil additional requirements in the context of grid integration. The paper examines to which extent wind turbines can provide positive control power following the related grid code. The additional power has to be obtained from the rotating flywheel mass of the wind turbine's rotor. A simple physical model is developed that allows to draw conclusions about appropriate concepts by means of a dynamic simulation of the variables rotational speed, torque, power output and rotor power. The paper discusses scenarios to provide control power. The supply of control power at partial load is examined in detail using simulations. Under partial load conditions control power can be fed into the grid for a short time. Thereby the rotational speed drops so that aerodynamic efficiency decreases and feed-in power is below the initial value after the control process. In this way an unfavourable situation for the grid control is produced, therefore the paper proposes a modified partial load condition with a higher rotational speed. By providing primary control power the rotor is delayed to the optimum rotational speed so that more rotational energy can be fed in and fed-in power can be increased persistently. However, as the rotor does not operate at optimum speed, a small amount of the energy yield is lost. Finally, the paper shows that a wind farm can combine these two concepts: A part of the wind turbines work under modified partial load conditions can compensate the decrease of power of the wind turbines working under partial load conditions. Therefore the requested control power is provided and afterwards the original value of power is maintained.

  9. Faraday effect on the Rb D{sub 1} line in a cell with a thickness of half the wavelength of light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sargsyan, A., E-mail: sarmeno@mail.ru, E-mail: sargsyanarmen85@gmail.com; Pashayan-Leroy, Y.; Leroy, C.

    2016-09-15

    The rotation of the radiation polarization plane in a longitudinal magnetic field (Faraday effect) on the D{sub 1} line in atomic Rb vapor has been studied with the use of a nanocell with the thickness L varying in the range of 100–900 nm. It has been shown that an important parameter is the ratio L/λ, where λ = 795 nm is the wavelength of laser radiation resonant with the D{sub 1} line. The best parameters of the signal of rotation of the radiation polarization plane have been obtained at the thickness L = λ/2 = 397.5 nm. The fabricated nanocellmore » had a large region with such a thickness. The spectral width of the signal reached at the thickness L = 397.5 nm is approximately 30 MHz, which is much smaller than the spectral width (≈ 500 MHz) reached with ordinary cells with a thickness in the range of 1–100 mm. The parameters of the Faraday rotation signal have been studied as functions of the temperature of the nanocell, the laser power, and the magnetic field strength. The signal has been reliably detected at the laser power P{sub L} ≥ 1 μW, magnetic field strength B ≥ 0.5 G, and the temperature of the nanocell T ≥ 100°C. It has been shown that the maximum rotation angle of the polarization plane in the longitudinal magnetic field is reached on the F{sub g} = 3 → F{sub e} = 2 transition of the {sup 85}Rb atom. The spectral profile of the Faraday rotation signal has a specific shape with a sharp peak, which promotes its applications. In particular, Rb atomic transitions in high magnetic fields about 1000 G are split into a large number of components, which are completely spectrally resolved and allow the study of the behavior of an individual transition.« less

  10. Development of methods of producing large areas of silicon sheet by the slicing of silicon ingots using Inside Diameter (I.D.) saws

    NASA Technical Reports Server (NTRS)

    Aharonyan, P.

    1980-01-01

    Modifications to a 16 inch STC automated saw included: a programmable feed system; a crystal rotating system; and a STC dynatrack blade boring and control system. By controlling the plating operation and by grinding the cutting edge, 16 inch I.D. blades were produced with a cutting edge thickness of .22 mm. Crystal rotation mechanism was used to slice 100 mm diameter crystals with a 16 inch blade down to a thickness of .20 mm. Cutting rates with crystal rotation were generally slower than with standard plunge I.D. slicing techniques. Using programmed feeds and programmed rotation, maximum cutting rates were from 0.3 to 1.0 inches per minute.

  11. Partial rotator cuff repair and biceps tenotomy for the treatment of patients with massive cuff tears and retained overhead elevation: midterm outcomes with a minimum 5 years of follow-up.

    PubMed

    Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G

    2016-11-01

    A subset of patients with massive irreparable rotator cuff tears present with retained overhead elevation and pain as their primary complaint. Our aim was to evaluate the outcomes of partial arthroscopic rotator cuff repair with biceps tenotomy and to report the failure rate of this procedure for patients with >5 years of follow-up. Thirty-four patients underwent partial rotator cuff repair and biceps tenotomy for treatment of a massive rotator cuff tear. Patients had preoperative active forward elevation >120° and no radiographic evidence of glenohumeral arthritis. Patients were followed up clinically and radiographically, and 28 patients had a minimum of 5 years of follow-up. Failure was defined as an American Shoulder and Elbow Surgeons score of <70, loss of active elevation >90°, or revision to reverse shoulder arthroplasty during the study period. Patients demonstrated improvements in average preoperative to postoperative American Shoulder and Elbow Surgeons scores (46.6 to 79.3 [P < .001]) and Simple Shoulder Test scores (5.7 to 9.1 [P < .001]) along with decrease in visual analog scale for pain scores (6.9 to 1.9 [P < .001]). No significant change in forward elevation (168° to 154° [P = .07]), external rotation (38° to 39° [P = 1.0]), or internal rotation (84% to 80% [P = 1.0]) was identified; 36% of patients had progression of the Hamada stage. The failure rate was 29%; 75% of patients were satisfied with their index procedure. Partial rotator cuff repair and biceps tenotomy for patients with massive irreparable rotator cuff tears with retained overhead elevation and pain as the primary complaint produced reasonable outcomes at midterm follow-up of at least 5 years. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Differential effects of Losartan and Atorvastatin in partial and full thickness burn wounds

    PubMed Central

    Akershoek, Johanneke J.; Brouwer, Katrien M.; Vlig, Marcel; Boekema, Bouke K. H. L.; Beelen, Rob H. J.; Middelkoop, Esther

    2017-01-01

    Healing of burn wounds is often associated with scar formation due to excessive inflammation and delayed wound closure. To date, no effective treatment is available to prevent the fibrotic process. The Renin Angiotensin System (RAS) was shown to be involved in fibrosis in various organs. Statins (e.g. Atorvastatin), Angiotensin receptor antagonists (e.g. Losartan) and the combination of these drugs are able to reduce the local RAS activation, and reduced fibrosis in other organs. We investigated whether inhibition of the RAS could improve healing of burn wounds by treatment with Atorvastatin, Losartan or the combination of both drugs. Therefore, full and partial thickness burn wounds were inflicted on both flanks of Yorkshire pigs. Oral administration of Atorvastatin, Losartan or the combination was started at post-burn day 1 and continued for 28 days. Full thickness wounds were excised and transplanted with an autologous meshed split-thickness skin graft at post-burn day 14. Partial thickness wounds received conservative treatment. Atorvastatin treatment resulted in enhanced graft take and wound closure of the full thickness wounds, faster resolution of neutrophils compared to all treatments and reduced alpha-smooth muscle actin positive cells compared to control treatment. Treatment with Losartan and to a lesser extent the combination therapy resulted in diminished graft take, increased wound contraction and poorer scar outcome. In contrast, Losartan treatment in partial thickness wounds decreased the alpha-smooth muscle actin+ fibroblasts and contraction. In conclusion, we showed differential effects of Losartan and Atorvastatin in full and partial thickness wounds. The extensive graft loss seen in Losartan treated wounds is most likely responsible for the poor clinical outcome of these full thickness burn wounds. Therefore, Losartan treatment should not be started before transplantation in order to prevent graft loss. Atorvastatin seems to accelerate the healing process in full thickness wounds possibly by dampening the pro-inflammatory response. PMID:28614412

  13. Differential effects of Losartan and Atorvastatin in partial and full thickness burn wounds.

    PubMed

    Akershoek, Johanneke J; Brouwer, Katrien M; Vlig, Marcel; Boekema, Bouke K H L; Beelen, Rob H J; Middelkoop, Esther; Ulrich, Magda M W

    2017-01-01

    Healing of burn wounds is often associated with scar formation due to excessive inflammation and delayed wound closure. To date, no effective treatment is available to prevent the fibrotic process. The Renin Angiotensin System (RAS) was shown to be involved in fibrosis in various organs. Statins (e.g. Atorvastatin), Angiotensin receptor antagonists (e.g. Losartan) and the combination of these drugs are able to reduce the local RAS activation, and reduced fibrosis in other organs. We investigated whether inhibition of the RAS could improve healing of burn wounds by treatment with Atorvastatin, Losartan or the combination of both drugs. Therefore, full and partial thickness burn wounds were inflicted on both flanks of Yorkshire pigs. Oral administration of Atorvastatin, Losartan or the combination was started at post-burn day 1 and continued for 28 days. Full thickness wounds were excised and transplanted with an autologous meshed split-thickness skin graft at post-burn day 14. Partial thickness wounds received conservative treatment. Atorvastatin treatment resulted in enhanced graft take and wound closure of the full thickness wounds, faster resolution of neutrophils compared to all treatments and reduced alpha-smooth muscle actin positive cells compared to control treatment. Treatment with Losartan and to a lesser extent the combination therapy resulted in diminished graft take, increased wound contraction and poorer scar outcome. In contrast, Losartan treatment in partial thickness wounds decreased the alpha-smooth muscle actin+ fibroblasts and contraction. In conclusion, we showed differential effects of Losartan and Atorvastatin in full and partial thickness wounds. The extensive graft loss seen in Losartan treated wounds is most likely responsible for the poor clinical outcome of these full thickness burn wounds. Therefore, Losartan treatment should not be started before transplantation in order to prevent graft loss. Atorvastatin seems to accelerate the healing process in full thickness wounds possibly by dampening the pro-inflammatory response.

  14. Improved optical filter

    NASA Technical Reports Server (NTRS)

    Title, A. M.

    1978-01-01

    Filter includes partial polarizer between birefrigent elements. Plastic film on partial polarizer compensates for any polarization rotation by partial polarizer. Two quarter-wave plates change incident, linearly polarized light into elliptically polarized light.

  15. Experimental study of icing accretion on a rotating conical spinner

    NASA Astrophysics Data System (ADS)

    Chen, Ningli; Ji, Honghu; Hu, Yaping; Wang, Jian; Cao, Guangzhou

    2015-12-01

    A reduced scale experiment has been conducted to investigate the icing accretion procedure on a rotating spinner of 60° cone angle. The experiment was carried out in a small scale ice wind tunnel with three different rotating speeds of the spinner. The experimental conditions were determined from the actual icing condition of the spinner of a turbofan engine by using the similarity theory, which considers the rotating effects. The ice thickness on the spinner was got from the image taken by the high speed camera, by image processing. The results of this investigation show that under the experimental condition, ice on the spinner's tip of three different rotating speeds are all glaze ice and about the same thick. However, on the downstream surface of the spinner, ice shape on the rotating spinner is different from that on the stationary spinner. It is uneven glaze ice on the stationary spinner while it is `particle ice' when the rotating speed is 8240 rpm and it is `needle ice' when the rotating speed is 15,200 rpm. The experiment also reveals that when the rotating speed is higher, the ice layer is thicker.

  16. Ultrasound dimensions of the rotator cuff in young healthy adults.

    PubMed

    Karthikeyan, Shanmugam; Rai, Santosh B; Parsons, Helen; Drew, Steve; Smith, Christopher D; Griffin, Damian R

    2014-08-01

    No studies have looked at the rotator cuff dimensions in the young healthy population using ultrasonography. Our aim is to define the ultrasound dimensions of the rotator cuff in the healthy young adult population and explore correlations with other patient characteristics. Thirty male and 30 female healthy volunteers (aged 18-40 years), with no shoulder problems, underwent ultrasound assessment of both shoulders by a musculoskeletal radiologist. The dimensions of the rotator cuff, deltoid, and biceps were measured in a standardized manner. A total of 120 shoulders were scanned. The mean maximum width of the supraspinatus footprint was 14.9 mm in men and 13.5 mm in women (P < .001). The mean thickness of the supraspinatus tendon was 4.9 mm in women and 5.6 mm in men. The mean thickness of the subscapularis was 4.4 in men and 3.8 mm in women and for the infraspinatus was 4.9 mm in men and 4.4 mm in women. There was no correlation between height, weight, biceps, or deltoid thickness with any tendon measurements. Apart from supraspinatus tendon thickness, the difference between dominant and nondominant shoulders in the same sex was not significant for any other tendon dimensions. This study has defined the dimensions of the rotator cuff in the young healthy adult, which has not been previously published. This is important for the documentation of normal ultrasound anatomy of the rotator cuff and also demonstrates that the asymptomatic contralateral shoulder can and should be used to estimate the expected dimensions. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  17. Spatial frequency domain imaging of burn wounds in a preclinical model of graded burn severity

    NASA Astrophysics Data System (ADS)

    Nguyen, John Quan; Crouzet, Christian; Mai, Tuan; Riola, Kathleen; Uchitel, Daniel; Liaw, Lih-Huei; Bernal, Nicole; Ponticorvo, Adrien; Choi, Bernard; Durkin, Anthony J.

    2013-06-01

    Frequent monitoring of early-stage burns is necessary for deciding optimal treatment and management. Both superficial and full thickness burns are relatively easy to diagnose based on clinical observation. In between these two extremes are superficial-partial thickness and deep-partial thickness burns. These burns, while visually similar, differ dramatically in terms of clinical treatment and are known to progress in severity over time. The objective of this study was to determine the potential of spatial frequency domain imaging (SFDI) for noninvasively mapping quantitative changes in chromophore and optical properties that may be an indicative of burn wound severity. A controlled protocol of graded burn severity was developed and applied to 17 rats. SFDI data was acquired at multiple near-infrared wavelengths over a course of 3 h. Burn severity was verified using hematoxylin and eosin histology. From this study, we found that changes in water concentration (edema), deoxygenated hemoglobin concentration, and optical scattering (tissue denaturation) to be statistically significant at differentiating superficial partial-thickness burns from deep-partial thickness burns.

  18. A MODEL FOR THE TEAR FILM AND OCULAR SURFACE TEMPERATURE FOR PARTIAL BLINKS

    PubMed Central

    Deng, Quan; Braun, R. J.; Driscoll, T. A.; King-Smith, P. E.

    2015-01-01

    In this paper, we investigate the dynamics of tear film and the associated temperature variation for partial blinks. We investigate the mechanism of fluid supply during partial blink cycles, and compare the film thickness with observation in vivo. We find that varying the thickness of the fluid layer beneath the moving upper lid improves the agreement for the in vivo measurement of tear film thickness after a half blink. By examining the flux of the fluid, we provide an explanation of this assumption. We also investigate the temperature dynamics both at the ocular surface and inside the simulated anterior chamber. Our simulation results suggest that the ocular surface temperature readjusts rapidly to normal temperature distribution after partial blinks. PMID:25635242

  19. An Examination of Exposure Control and Content Balancing Restrictions on Item Selection in CATs Using the Partial Credit Model.

    ERIC Educational Resources Information Center

    Davis, Laurie Laughlin; Pastor, Dena A.; Dodd, Barbara G.; Chiang, Claire; Fitzpatrick, Steven J.

    2003-01-01

    Examined the effectiveness of the Sympson-Hetter technique and rotated content balancing relative to no exposure control and no content rotation conditions in a computerized adaptive testing system based on the partial credit model. Simulation results show the Sympson-Hetter technique can be used with minimal impact on measurement precision,…

  20. Can activity within the external abdominal oblique be measured using real-time ultrasound imaging?

    PubMed

    John, E K; Beith, I D

    2007-11-01

    Differences in the function of the anterolateral abdominal muscles have been the subject of much investigation, but primarily using electromyography. Recently changes in thickness of transversus abdominis and internal oblique measured from real-time ultrasound images have been shown to represent activity within these muscles. However it is still unclear if such a change in thickness in external oblique similarly represents activity within that muscle. The purpose of this study was to investigate the relationship between change in thickness and muscle activity in the external oblique using real-time ultrasound and surface electromyography. Simultaneous measurements of electromyography and real-time ultrasound images of external oblique were studied in up to 24 subjects during two tasks compared to the muscle at rest (1) isometric trunk rotation and (2) drawing in the lower abdomen. Changes in muscle thickness correlated significantly with electromyography during isometric trunk rotation in the majority of subjects but with a significant difference between subjects. In contrast, the relationship between change in thickness and electrical activity in the muscle when drawing in the lower abdomen was significant in less than 50% of subjects and the muscle often got thinner. Thickness changes of external oblique can be used as a valid indicator of electromyography activity during isometric trunk rotation, though the relationship is not as good as previously published data for transversus abdominis. Thickness changes of external oblique measured during lower abdominal drawing in cannot be used to detect activity within this muscle.

  1. Partial articular-sided rotator cuff tears: in situ repair versus tear completion prior to repair.

    PubMed

    Sethi, Paul M; Rajaram, Arun; Obopilwe, Elifho; Mazzocca, Augustus D

    2013-06-01

    Uncertainty exists over the ideal surgical treatment method for partial articular-sided rotator cuff tears, with options ranging from debridement to in situ repair to tear completion prior to repair. The purpose of this study was to determine whether in situ repair was a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. Fourteen fresh-frozen cadaveric shoulders were dissected. Partial articular-sided tears were created and repaired using in situ repair or tear completion prior to the repair. Strain and displacement were measured at 45°, 60°, and 90° of glenohumeral abduction. Testing was performed with a load of 100 N applied for 30 cycles. Data from the biomechanical testing displayed 4 conditions that showed improved characteristics of in situ repair over completion and repair: bursal-sided strain anteriorly at 45°, bursal-sided strain anteriorly at 90°, bursal-sided displacement anteriorly at 45°, and bursal-sided displacement anteriorly at 90°. The data indicate that in situ repair is a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. When clinically appropriate, the in situ repair may offer some biomechanical advantages, with lower strain and displacement observed on the bursal side compared with tear completion prior to repair. Copyright 2013, SLACK Incorporated.

  2. Pulley lesions in rotator cuff tears: prevalence, etiology, and concomitant pathologies.

    PubMed

    Hawi, Nael; Liodakis, Emmanouil; Garving, Christina; Habermeyer, Peter; Tauber, Mark

    2017-08-01

    This study aimed to demonstrate the prevalence of lesions in the biceps pulley complex in a representative, consecutive series of rotator cuff tears and rotator cuff interval treatments. We also analyzed associated tear pattern of rotator cuff injuries and superior labrum anterior-posterior (SLAP) lesions. We evaluated the relationships of these lesions to traumatic genesis and the prevalence of pulley lesions in revision cases. This retrospective study analyzed all pre- and intra-operative documentation on arthroscopic rotator cuff reconstructions and isolated pulley lesion treatments performed by a single surgeon over 2 consecutive years. According to Habermeyer et al., we classified cases into four groups, based on the presence of additional or related complete or partial rotator cuff tears, SLAP lesions, trauma, and primary or revision surgery. Among 382 patients with rotator cuff tears, 345 (90.3%) had an injured pulley system; 151 (43.8%) had partial tears of the rotator cuff; out of these, 106 (30.6%) were articular-sided. All of these articular-sided partial tears showed extension into the pulley complex. In 154 cases (44.6%), history of shoulder trauma was associated with the beginning of symptoms. In addition, concomitant SLAP lesions occurred in 25-62% of pulley lesions, correlating with the severity of pulley lesions. Among the 345 cases, there have been 32 (9.3%) revision cases where a pulley lesion was intra-operatively identified and addressed. Pulley complex lesions are present in 90.3% of surgically treated rotator cuff lesions, particularly in articular-sided injuries. In addition, we found a significant relationship between the incidence of SLAP lesions and the severity of pulley lesions. It seems reasonable to assume an important role of pulley system injuries in the pathogenesis of rotator cuff lesions.

  3. Lifestyle and metabolic factors in relation to shoulder pain and rotator cuff tendinitis: A population-based study

    PubMed Central

    2010-01-01

    Background Shoulder pain is a common health problem. The purpose of this study was to assess the associations of lifestyle factors, metabolic factors and carotid intima-media thickness with shoulder pain and chronic (> 3 months) rotator cuff tendinitis. Methods In this cross-sectional study, the target population consisted of subjects aged 30 years or older participating in a national Finnish Health Survey during 2000-2001. Of the 7,977 eligible subjects, 6,237 (78.2%) participated in a structured interview and clinical examination. Chronic rotator cuff tendinitis was diagnosed clinically. Weight-related factors, C-reactive protein and carotid intima-media thickness were measured. Results The prevalence of shoulder joint pain during the preceding 30 days was 16% and that of chronic rotator cuff tendinitis 2.8%. Smoking, waist circumference and waist-to-hip ratio were related to an increased prevalence of shoulder pain in both genders. Metabolic syndrome, type 2 diabetes mellitus and carotid intima-media thickness were associated with shoulder pain in men, whereas high level of C-reactive protein was associated with shoulder pain in women. Increased waist circumference and type 1 diabetes mellitus were associated with chronic rotator cuff tendinitis in men. Conclusions Our findings showed associations of abdominal obesity, some other metabolic factors and carotid intima-media thickness with shoulder pain. Disturbed glucose metabolism and atherosclerosis may be underlying mechanisms, although not fully supported by the findings of this study. Prospective studies are needed to further investigate the role of lifestyle and metabolic factors in shoulder disorders. PMID:20646281

  4. Lifestyle and metabolic factors in relation to shoulder pain and rotator cuff tendinitis: a population-based study.

    PubMed

    Rechardt, Martti; Shiri, Rahman; Karppinen, Jaro; Jula, Antti; Heliövaara, Markku; Viikari-Juntura, Eira

    2010-07-20

    Shoulder pain is a common health problem. The purpose of this study was to assess the associations of lifestyle factors, metabolic factors and carotid intima-media thickness with shoulder pain and chronic (> 3 months) rotator cuff tendinitis. In this cross-sectional study, the target population consisted of subjects aged 30 years or older participating in a national Finnish Health Survey during 2000-2001. Of the 7,977 eligible subjects, 6,237 (78.2%) participated in a structured interview and clinical examination. Chronic rotator cuff tendinitis was diagnosed clinically. Weight-related factors, C-reactive protein and carotid intima-media thickness were measured. The prevalence of shoulder joint pain during the preceding 30 days was 16% and that of chronic rotator cuff tendinitis 2.8%. Smoking, waist circumference and waist-to-hip ratio were related to an increased prevalence of shoulder pain in both genders. Metabolic syndrome, type 2 diabetes mellitus and carotid intima-media thickness were associated with shoulder pain in men, whereas high level of C-reactive protein was associated with shoulder pain in women. Increased waist circumference and type 1 diabetes mellitus were associated with chronic rotator cuff tendinitis in men. Our findings showed associations of abdominal obesity, some other metabolic factors and carotid intima-media thickness with shoulder pain. Disturbed glucose metabolism and atherosclerosis may be underlying mechanisms, although not fully supported by the findings of this study. Prospective studies are needed to further investigate the role of lifestyle and metabolic factors in shoulder disorders.

  5. Relationship of Tear Size and Location to Fatty Degeneration of the Rotator Cuff

    PubMed Central

    Kim, H. Mike; Dahiya, Nirvikar; Teefey, Sharlene A.; Keener, Jay D.; Galatz, Leesa M.; Yamaguchi, Ken

    2010-01-01

    Background: Fatty degeneration of the rotator cuff muscles may have detrimental effects on both anatomical and functional outcomes following shoulder surgery. The purpose of this study was to investigate the relationship between tear geometry and muscle fatty degeneration in shoulders with a deficient rotator cuff. Methods: Ultrasonograms of both shoulders of 262 patients were reviewed to assess the type of rotator cuff tear and fatty degeneration in the supraspinatus and infraspinatus muscles. The 251 shoulders with a full-thickness tear underwent further evaluation for tear size and location. The relationship of tear size and location to fatty degeneration of the supraspinatus and infraspinatus muscles was investigated with use of statistical comparisons and regression models. Results: Fatty degeneration was found almost exclusively in shoulders with a full-thickness rotator cuff tear. Of the 251 shoulders with a full-thickness tear, eighty-seven (34.7%) had fatty degeneration in either the supraspinatus or infraspinatus, or both. Eighty-two (32.7%) of the 251 full-thickness tears had a distance of 0 mm between the biceps tendon and anterior margin of the tear. Ninety percent of the full-thickness tears with fatty degeneration in both muscles had a distance of 0 mm posterior from the biceps, whereas only 9% of those without fatty degeneration had a distance of 0 mm. Tears with fatty degeneration had significantly greater width and length than those without fatty degeneration (p < 0.0001). Tears with fatty degeneration had a significantly shorter distance posterior from the biceps than those without fatty degeneration (p < 0.0001). The distance posterior from the biceps was found to be the most important predictor for supraspinatus fatty degeneration, whereas tear width and length were found to be the most important predictors for infraspinatus fatty degeneration. Conclusions: Fatty degeneration of the rotator cuff muscles is closely associated with tear size and location. The finding of this study suggests that the integrity of the anterior supraspinatus tendon is important to the development of fatty degeneration. Patients with full-thickness tears that extend through this area may benefit from earlier surgical intervention if fatty degeneration has not already occurred. Additionally, the findings suggest the importance of secure fixation and healing of the anterior aspect of the supraspinatus with surgical repair. PMID:20360505

  6. On chemical reaction and porous medium effect in the MHD flow due to a rotating disk with variable thickness

    NASA Astrophysics Data System (ADS)

    Hayat, Tasawar; Nazar, Hira; Imtiaz, Maria; Alsaedi, Ahmed

    2017-06-01

    The present analysis describes the magnetohydrodynamic (MHD) axisymmetric flow of a viscous fluid due to a rotating disk with variable thickness. An electrically conducting fluid fills the porous space. The first-order chemical reaction is considered. The equations of the present problem representing the flow of a fluid are reduced into nonlinear ordinary differential equations. Convergent series solutions are obtained. The impacts of the various involved dimensionless parameters on fluid flow, temperature, concentration, skin frction coefficient and Nusselt number are examined. The radial, tangential and axial components of velocity are affected in a similar manner on changing the thickness coefficient of the disk. Similar effects of the disk thickness coefficient are observed for both the temperature and concentration profile.

  7. Functional evaluation of patient after arthroscopic repair of rotator cuff tear.

    PubMed

    Kumar, Rohit; Jadhav, Umesh

    2014-06-01

    Rotator cuff tear is a common problem either after trauma or after degenerative tear in old age group. Arthroscopic repair is the current concept of rotator cuff repair. Here, we are trying to evaluate the functional outcome after arthroscopic repair of full thickness rotator cuff tear (single row) in Indian population. Twenty five patients (14 males and 11 females) who underwent arthroscopic repair of full thickness rotator cuff tear at a single institution were included in the study. Postoperatively patient's shoulder was rated according to UCLA score, pain was graded according to the visual analog score. The range of motion was analysed and documented. The mean age of the patients were 50.48 years. The preoperative VAS score mode was 7 and post operative VAS was 1 (p value <0.001). The UCLA grading was good in 80% (n = 20), fair in 12% (n = 3), excellent in 8% (n = 2) and poor results were seen in none of the patients. The mean UCLA improved from a score of 15.84 to 30.28 with a p value <0.001. Mean postoperative forward flexion was 161.6°, mean abduction was 147.6° and mean external rotation was 45.4°. Arthroscopic repair is a good procedure for full thickness rotator cuff tear with minimal complications. The newer double row repair claims to be biomechanically superior with faster healing rates without functional advantages, hence we used a single row repair considering the Indian population and the cost effectiveness of the surgery with good to excellent results.

  8. Magnetic resonance imaging assessment of the rotator cuff: is it really accurate?

    PubMed

    Wnorowski, D C; Levinsohn, E M; Chamberlain, B C; McAndrew, D L

    1997-12-01

    Magnetic resonance imaging (MRI) is used increasingly for evaluating the rotator cuff. This study of 39 shoulders (38 patients) compared the accuracy of MRI interpretation of rotator cuff integrity by a group of community hospital radiologists (clinical community scenario, CCS) with that of a musculoskeletal radiologist (experienced specialist scenario, ESS), relative to arthroscopy. For the CCS subgroup, the sensitivity, specificity, positive predictive value (PV), negative PV, and accuracy for partial tears were: 0%, 68%, 0%, 82%, and 59%, respectively; for complete tears: 56%, 73%, 36%, 86%, and 69%, respectively; and for all tears combined: 85%, 52%, 50%, 87%, and 64%, respectively. For the ESS subgroup, the respective values for partial tears were: 20%, 88%, 20%, 88%, and 79%, respectively; for complete tears: 78%, 83%, 58%, 92%, and 82%, respectively; and for all tears: 71%, 71%, 59%, 81%, and 71%, respectively. We concluded that MRI assessment of the rotator cuff was not accurate relative to arthroscopy. MRI was most helpful if the result was negative, and MRI diagnosis of partial tear was of little value. Considering the high cost of shoulder MRI, this study has significant implications for the evaluation of patients with possible rotator cuff pathology.

  9. Effect of Cattaneo-Christov heat flux on Jeffrey fluid flow with variable thermal conductivity

    NASA Astrophysics Data System (ADS)

    Hayat, Tasawar; Javed, Mehwish; Imtiaz, Maria; Alsaedi, Ahmed

    2018-03-01

    This paper presents the study of Jeffrey fluid flow by a rotating disk with variable thickness. Energy equation is constructed by using Cattaneo-Christov heat flux model with variable thermal conductivity. A system of equations governing the model is obtained by applying boundary layer approximation. Resulting nonlinear partial differential system is transformed to ordinary differential system. Homotopy concept leads to the convergent solutions development. Graphical analysis for velocities and temperature is made to examine the influence of different involved parameters. Thermal relaxation time parameter signifies that temperature for Fourier's heat law is more than Cattaneo-Christov heat flux. A constitutional analysis is made for skin friction coefficient and heat transfer rate. Effects of Prandtl number on temperature distribution and heat transfer rate are scrutinized. It is observed that larger Reynolds number gives illustrious temperature distribution.

  10. Classification of full-thickness rotator cuff lesions: a review

    PubMed Central

    Lädermann, Alexandre; Burkhart, Stephen S.; Hoffmeyer, Pierre; Neyton, Lionel; Collin, Philippe; Yates, Evan; Denard, Patrick J.

    2016-01-01

    Rotator cuff lesions (RCL) have considerable variability in location, tear pattern, functional impairment, and repairability. Historical classifications for differentiating these lesions have been based upon factors such as the size and shape of the tear, and the degree of atrophy and fatty infiltration. Additional recent descriptions include bipolar rotator cuff insufficiency, ‘Fosbury flop tears’, and musculotendinous lesions. Recommended treatment is based on the location of the lesion, patient factors and associated pathology, and often includes personal experience and data from case series. Development of a more comprehensive classification which integrates historical and newer descriptions of RCLs may help to guide treatment further. Cite this article: Lädermann A, Burkhart SS, Hoffmeyer P, et al. Classification of full thickness rotator cuff lesions: a review. EFORT Open Rev 2016;1:420-430. DOI: 10.1302/2058-5241.1.160005. PMID:28461921

  11. Emergence and transitions of dynamic patterns of thickness oscillation of the plasmodium of the true slime mold Physarum polycephalum

    NASA Astrophysics Data System (ADS)

    Takagi, Seiji; Ueda, Tetsuo

    2008-03-01

    The emergence and transitions of various spatiotemporal patterns of thickness oscillation were studied in the freshly isolated protoplasm of the Physarum plasmodium. New patterns, such as standing waves, and chaotic and rotating spirals, developed successively before the well-documented synchronous pattern appeared. There was also a spontaneous opposite transition from synchrony to chaotic and rotating spirals. Rotating spiral waves were observed in the large migrating plasmodium, where the vein structures were being destroyed. Thus, the Physarum plasmodium exhibits versatile patterns, which are generally expected in coupled oscillator systems. This paper discusses the physiological roles of spatiotemporal patterns, comparing them with other biological systems.

  12. Complete vs partial-thickness tears of the posterior cruciate ligament: MR findings.

    PubMed

    Patten, R M; Richardson, M L; Zink-Brody, G; Rolfe, B A

    1994-01-01

    We sought to define the MRI appearance of both complete and partial-thickness tears of the posterior cruciate ligament (PCL) and to describe patterns of injury and associated MRI findings. Three radiologists retrospectively reviewed MR images and medical records on 32 patients with PCL tears (15 complete, 17 partial) and correlated MRI findings to results of clinical testing and surgery. The PCL had indistinct margins in 27 (84%) of 32 patients and was abnormally thick in 25 (78%) patients. In 31 (97%) patients, the torn PCL showed increased signal intensity on both T1- and T2-weighted pulse sequences. Although there was no statistically significant difference between patients with complete tears and those with partial tears with regard to thickness, margination, and signal intensity of the PCL, MR images in patients with complete tears were more likely to show focal areas of ligamentous discontinuity (10 of 15 cases) (p = 0.01). Associated knee injuries were seen in 21 (66%) patients and were seen more frequently in patients with complete PCL tears (p = 0.015). Bony injury (n = 11, 34%) and tears of the medial collateral ligament (n = 13, 41%) and menisci (n = 10, 31%) were common. No specific pattern of bony injury was found. Posterior cruciate ligament tears can be diagnosed readily by multiplanar MRI using both morphological and signal intensity characteristics. Although differentiation between complete and partial-thickness PCL tears by MRI criteria alone is more problematic, complete tears are more likely to show focal areas of discontinuity and partial tears are more likely to show at least some intact fibers.

  13. Management of a facial partial thickness chemical burn in a dog caused by bleach.

    PubMed

    Kawalilak, Lukas T; Fransson, Boel A; Alessio, Terri L

    2017-03-01

    To describe the management and successful outcome of a late-recognition partial thickness bleach burn to the face and corneas of a dog. A 1-year-old male neutered Fox Terrier mix breed dog was evaluated for sloughing facial epithelium 5 days after coming into contact with an 8.25% household bleach cleaning solution. Severe erythema, edema, and crusting were noted around the muzzle and margins of both eyes, with moderate to severe alopecia in these areas. A partially detached, partial thickness eschar was present on the muzzle, while a firmly attached eschar was present in the region of both frontal sinuses. These injuries were consistent with a focal, superficial, and partial thickness chemical burn. Multiple ocular abnormalities, the most concerning of which was corneal ulceration, were also present. The patient's wounds were managed conservatively with limited surgical debridement of the affected epithelium 11 and 22 days after the initial exposure. Topical ocular medications, corneal debridement, and a superficial keratectomy were also used. All lesions resolved completely by 84 days postexposure, with no residual effects on the patient's quality of life. Chemical burns caused by contact with alkaline agents such as bleach (sodium hypochlorite) result in extensive necrosis of the skin and underlying structures. This is the first report of management alkaline facial burns in a dog. If inadequate or delayed hydrotherapy following exposure has resulted in superficial partial thickness burns, conservative management can be successful when traditional treatments, especially bandaging, are not feasible. © Veterinary Emergency and Critical Care Society 2017.

  14. Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis.

    PubMed

    Huang, Chun-Hsiung; Ma, Hon-Ming; Liau, Jiann-Jong; Ho, Fang-Yuan; Cheng, Cheng-Kung

    2002-12-01

    Five patients with late rotational dislocation of the rotating platform bearing in the New Jersey Low-Contact Stress total knee arthroplasty are reported. The prostheses had functioned well for 8 to 12 years before failure. Preoperative radiographs showed asymmetric femorotibial joint spaces. Entrapment of the dislocated bearing in three patients and spontaneous reduction of the dislocated bearing in another two patients were seen at revision. Femorotibial ligamentous instability was found after reduction. The retrieved polyethylene bearings showed advanced wear and cold flow deformities and the thickness was reduced. The revision arthroplasty was accomplished by replacement with a thicker bearing element. Progressive femorotibial ligament laxity and reduction of the thickness of polyethylene with wearing break down the originally well-balanced soft tissue tension of the knee. The rotational degree of the rotating platform bearing is unrestricted, which may result in late dislocation. Polyethylene wear is unavoidable in knee prostheses using metal contact with polyethylene even with a mobile-bearing design. Efforts to reduce polyethylene wear are mandatory.

  15. Poster — Thur Eve — 10: Partial kV CBCT, complete kV CBCT and EPID in breast treatment: a dose comparison study for skin, breasts, heart and lungs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roussin, E; Archambault, L K; Wierzbicki, W

    The advantages of kilovoltage cone beam CT (kV CBCT) imaging over electronic portal imaging device (EPID) such as accurate 3D anatomy, soft tissue visualization, fast rigid registration and enhanced precision on patient positioning has lead to its increasing use in clinics. The benefits of this imaging technique are at the cost of increasing the dose to healthy surrounding organs. Our center has moved toward the use of daily partial rotation kV CBCT to restrict the dose to healthy tissues. This study aims to better quantify radiation doses from different image-guidance techniques such as tangential EPID, complete and partial kV CBCTmore » for breast treatments. Cross-calibrated ionization chambers and kV calibrated Gafchromic films were used to measure the dose to the heart, lungs, breasts and skin. It was found that performing partial kV CBCT decreases the heart dose by about 36%, the lungs dose by 31%, the contralateral breast dose by 41% and the ipsilateral breast dose by 43% when compared to a full rotation CBCT. The skin dose measured for a full rotation CBCT was about 0.8 cGy for the contralateral breast and about 0.3 cGy for the ipsilateral breast. The study is still ongoing and results on skin doses for partial rotation kV CBCT as well as for tangential EPID images are upcoming.« less

  16. Three-dimensional modelling of thin liquid films over spinning disks

    NASA Astrophysics Data System (ADS)

    Zhao, Kun; Wray, Alex; Yang, Junfeng; Matar, Omar

    2016-11-01

    In this research the dynamics of a thin film flowing over a rapidly spinning, horizontal disk is considered. A set of non-axisymmetric evolution equations for the film thickness, radial and azimuthal flow rates are derived using a boundary-layer approximation in conjunction with the Karman-Polhausen approximation for the velocity distribution in the film. These highly nonlinear partial differential equations are then solved numerically in order to reveal the formation of two and three-dimensional large-amplitude waves that travel from the disk inlet to its periphery. The spatio-temporal profile of film thickness provides us with visualization of flow structures over the entire disk and by varying system parameters(volumetric flow rate of fluid and rotational speed of disk) different wave patterns can be observed, including spiral, concentric, smooth waves and wave break-up in exceptional conditions. Similar types of waves can be found by experimentalists in literature and CFD simulation and our results show good agreement with both experimental and CFD results. Furthermore, the semi-parabolic velocity profile assumed in our model under the waves is directly compared with CFD data in various flow regimes in order to validate our model. EPSRC UK Programme Grant EP/K003976/1.

  17. The Societal and Economic Value of Rotator Cuff Repair

    PubMed Central

    Mather, Richard C.; Koenig, Lane; Acevedo, Daniel; Dall, Timothy M.; Gallo, Paul; Romeo, Anthony; Tongue, John; Williams, Gerald

    2013-01-01

    Background: Although rotator cuff disease is a common musculoskeletal problem in the United States, the impact of this condition on earnings, missed workdays, and disability payments is largely unknown. This study examines the value of surgical treatment for full-thickness rotator cuff tears from a societal perspective. Methods: A Markov decision model was constructed to estimate lifetime direct and indirect costs associated with surgical and continued nonoperative treatment for symptomatic full-thickness rotator cuff tears. All patients were assumed to have been unresponsive to one six-week trial of nonoperative treatment prior to entering the model. Model assumptions were obtained from the literature and data analysis. We obtained estimates of indirect costs using national survey data and patient-reported outcomes. Four indirect costs were modeled: probability of employment, household income, missed workdays, and disability payments. Direct cost estimates were based on average Medicare reimbursements with adjustments to an all-payer population. Effectiveness was expressed in quality-adjusted life years (QALYs). Results: The age-weighted mean total societal savings from rotator cuff repair compared with nonoperative treatment was $13,771 over a patient’s lifetime. Savings ranged from $77,662 for patients who are thirty to thirty-nine years old to a net cost to society of $11,997 for those who are seventy to seventy-nine years old. In addition, surgical treatment results in an average improvement of 0.62 QALY. Societal savings were highly sensitive to age, with savings being positive at the age of sixty-one years and younger. The estimated lifetime societal savings of the approximately 250,000 rotator cuff repairs performed in the U.S. each year was $3.44 billion. Conclusions: Rotator cuff repair for full-thickness tears produces net societal cost savings for patients under the age of sixty-one years and greater QALYs for all patients. Rotator cuff repair is cost-effective for all populations. The results of this study should not be interpreted as suggesting that all rotator cuff tears require surgery. Rather, the results show that rotator cuff repair has an important role in minimizing the societal burden of rotator cuff disease. PMID:24257656

  18. The Study of Galactic Disk Kinematics with SCUSS and SDSS Data

    NASA Astrophysics Data System (ADS)

    Peng, Xiyan; Wu, Zhenyu; Qi, Zhaoxiang; Du, Cuihua; Ma, Jun; Zhou, Xu; Jia, Yunpeng; Wang, Songhu

    2018-07-01

    We derive chemical and kinematics properties of G and K dwarfs from the SCUSS and SDSS data. We aim to characterize and explore the properties of the Galactic disk in order to understand their origins and evolutions. A kinematics approach is used to separate Galactic stellar populations into the likely thin disk and thick disk sample. Then, we explore rotational velocity gradients with metallicity of the Galactic disks to provide constraints on the various formation models. We identify a negative gradient of the rotational velocity of the thin disk stars with [Fe/H], ‑18.2 ± 2.3 km s‑1 dex‑1. For the thick disk, we identify a positive gradient of the rotational velocity with [Fe/H], 41.7 ± 6.1 km s‑1 dex‑1. The eccentricity does not change with metallicity for the thin disk sample. Thick disk stars exhibit a trend of orbital eccentricity with metallicity (‑0.13 dex‑1). The thin disk shows a negative metallicity gradient with Galactocentric radial distance R, while the thick disk shows a flat radial metallicity gradient. Our results suggest that radial migration may play an important role in the formation and evolution of the thin disk.

  19. Influences of Friction Stir Welding Parameters on Microstructural and Mechanical Properties of AA5456 (AlMg5) at Different Lap Joint Thicknesses

    NASA Astrophysics Data System (ADS)

    Pishevar, M. R.; Mohandesi, J. Aghazadeh; Omidvar, H.; Safarkhanian, M. A.

    2015-10-01

    Friction stir welding is suitable for joining series 5000 alloys because no fusion welding problems arise for the alloys in this process. The present study examined the effects of double-pass welding and tool rotational and travel speeds for the second-pass welding on the mechanical and microstructural properties of friction stir lap welding of AA5456 (AlMg5)-H321 (5 mm thickness) and AA5456 (AlMg5)-O (2.5 mm thickness). The first pass of all specimens was performed at a rotational speed of 650 rpm and a travel speed of 50 mm/min. The second pass was performed at rotational speeds of 250, 450, and 650 rpm and travel speeds of 25, 50, and 75 mm/min. The results showed that the second pass changed the grain sizes in the center of the nugget zone compared with the first pass. It was observed that the size of the hooking defect of the double-pass-welded specimens was higher than that for the single-pass-welded specimen. The size of the hooking defect was found to be a function of the rotational and travel speeds. The optimal joint tensile shear properties were achieved at a rotational speed of 250 rpm and travel a speed of 75 mm/min.

  20. Effects of bone marrow aspirate concentrate and platelet-rich plasma on patients with partial tear of the rotator cuff tendon.

    PubMed

    Kim, Sang Jun; Kim, Eun Kyung; Kim, Sun Jeong; Song, Da Hyun

    2018-01-03

    We compared the clinical course of rotator cuff tears between rotator cuff exercise and bone marrow aspirate concentration (BMAC)-platelet rich plasma (PRP) injection to identify the therapeutic effects of BMAC-PRP on partial tear of the rotator cuff tendon. Twenty-four patients with partial tear of the rotator cuff tendon participated in this study. Twelve patients underwent extraction of BMACs and PRP and received the injection of BMAC-PRP at the tear site under ultrasound guidance. Twelve patients in the control group were asked to perform the rotator cuff exercise for 3 months. Visual analog scale (VAS) and manual muscle test (MMT) scores of the supraspinatus muscle were measured, and the American Shoulder and Elbow Surgeons (ASES) score was recorded before, 3 weeks, and 3 months after injection. Tear size was measured by the greatest longitudinal tear length. The change in the VAS differed between groups at 3 months (P = 0.039) but not at 3 weeks (P = 0.147). The ASES scores in the BMAC-PRP group changed from 39.4 ± 13.0 to 54.5 ± 11.5 at 3 weeks and 74.1 ± 8.5 at 3 months while those in the control group changed from 45.9 ± 12.4 to 56.3 ± 12.3 at 3 weeks (P = 0.712) and 62.2 ± 12.2 at 3 months (P = 0.011). The tear size decreased at 3 weeks or 3 months after the BMAC-PRP injection but was not significantly different from that in the control group. BMAC-PRP improved pain and shoulder function in patients with partial tear of the rotator cuff tendon. The patients were registered in the institutional board registry of Samsung Medical Center (registry number 2014-07-173 ).

  1. Quantitative evaluation of the relationship between dorsal wall length, sole thickness, and rotation of the distal phalanx in the bovine claw using computed tomography.

    PubMed

    Tsuka, T; Murahata, Y; Azuma, K; Osaki, T; Ito, N; Okamoto, Y; Imagawa, T

    2014-10-01

    Computed tomography (CT) was performed on 800 untrimmed claws (400 inner claws and 400 outer claws) of 200 pairs of bovine hindlimbs to investigate the relationships between dorsal wall length and sole thickness, and between dorsal wall length and the relative rotation angle of distal phalanx-to-sole surface (S-D angle). Sole thickness was 3.8 and 4.0 mm at the apex of the inner claws and outer claws, respectively, with dorsal wall lengths <70 mm. These sole thickness values were less than the critical limit of 5 mm, which is associated with a softer surface following thinning of the soles. A sole thickness of 5 mm at the apex was estimated to correlate with dorsal wall lengths of 72.1 and 72.7 mm for the inner and outer claws, respectively. Sole thickness was 6.1 and 6.4 mm at the apex of the inner and outer claws, respectively, with dorsal wall lengths of 75 mm. These sole thickness values were less than the recommended sole thickness of 7 mm based on the protective function of the soles. A sole thickness >7 mm at the apex was estimated to correlate with a dorsal wall length of 79.8 and 78.4mm for the inner and outer claws, respectively. The S-D angles were recorded as anteversions of 2.9° and 4.7° for the inner and outer claws, respectively, with a dorsal wall length of 75 mm. These values indicate that the distal phalanx is likely to have rotated naturally forward toward the sole surface. The distal phalanx rotated backward to the sole surface at 3.2° and 7.6° for inner claws with dorsal wall lengths of 90-99 and ≥100 mm, respectively; and at 3.5° for outer claws with a dorsal wall length ≥100 mm. Dorsal wall lengths of 85.7 and 97.2 mm were estimated to correlate with a parallel positional relationship of the distal phalanx to the sole surface in the inner and outer claws, respectively. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  2. Moist Exposed Burn Ointment (MEBO) in partial thickness burns - a randomized, comparative open mono-center study on the efficacy of dermaheal (MEBO) ointment on thermal 2nd degree burns compared to conventional therapy.

    PubMed

    Hirsch, T; Ashkar, W; Schumacher, O; Steinstraesser, L; Ingianni, G; Cedidi, C C

    2008-11-24

    Wound healing in burn wounds presents a challenge in healthcare, and there is still a lack of alternatives in topical burn wound treatments. - The purpose of this study was to evaluate the efficacy of a new therapeutic ointment (MEBO) in the treatment of partial thickness burns. 40 patients received either topical treatment with Moist Exposed Burn Ointment (MEBO) or standard Flammazine treatment. All patients suffered from partial-thickness burn injuries (< 20% TBSA). Wounds were evaluated for 60 up to days regarding wound healing, water loss, inflammation, and pain alleviation. For transepidermal water loss, there was a difference of 2.3 gr/m2/h between MEBO, and Flammazine, favoring MEBO. However, this difference was not statistically significant (p=0.78). For all secondary efficacy parameter results were similar. - This study showed that MEBO ointment for topical treatment of burn injuries presents an attractive alternative for the topical treatment of limited partial thickness thermal burns.

  3. Effects of weld defects at root on rotating bending fatigue strength of small diameter socket welded pipe joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higuchi, Makoto; Nakagawa, Akira; Chujo, Noriyuki

    1996-12-01

    Rotating bending fatigue tests were conducted on socket welded joints of a nominal diameter 20 mm, and effects of root defect and other various factors, including post-weld heat treatment (PWHT), pipe wall thickness, and socket wall thickness, were investigated. The socket joints exhibited, in the rotating bending fatigue mode, fatigue strengths that were markedly lower than the same 20 mm diameter joints in four-point bending fatigue. Also, where the latter specimens failed always at the toe, root-failures occurred in rotating bending fatigue. When PWHT`d, however, the fatigue strength showed a remarkable improvement, while the failure site reverted to toe. Thickermore » pipe walls and socket walls gave rise to higher fatigue strength. A formula relating the size of root defects to the fatigue strength reduction has been proposed.« less

  4. Honey compared with silver sulphadiazine in the treatment of superficial partial-thickness burns.

    PubMed

    Malik, Kamran Ishaque; Malik, M A Nasir; Aslam, Azhar

    2010-10-01

    Burn injury is associated with a high incidence of death and disability; yet, its management remains problematic and costly. We conducted this clinical study to evaluate the efficacy of honey in the treatment of superficial and partial-thickness burns covering less than 40% of body surface area and compared its results with those of silver sulphadiazine (SSD). In this randomised comparative clinical trial, carried out Burn Center of POF Hospital, Wah Cantt, Pakistan, from May 2007 to February 2008, 150 patients of all ages having similar types of superficial and partial-thickness burns at two sites on different parts of body were included. Each patient had one burn site treated with honey and one treated with topical SSD, randomly. The rate of re-epithelialization and healing of superficial and partial-thickness burns was significantly faster in the sites treated with honey than in the sites treated with SSD (13·47 ± 4·06 versus 15·62 ± 4·40 days, respectively: P < 0·0001). The site treated with honey healed completely in less than 21 days versus 24 days for the site treated with SSD. Six patients had positive culture for Pseudomonas aeroginsa in honey-treated site, whereas 27 patients had positive culture in SSD-treated site. The results clearly showed greater efficacy of honey over SSD cream for treating superficial and partial-thickness burns. 2010 The Authors. Journal Compilation © 2010 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  5. General relativistic treatment of the thermal, magnetic and rotational evolution of isolated neutron stars with crustal magnetic fields

    NASA Astrophysics Data System (ADS)

    Page, D.; Geppert, U.; Zannias, T.

    2000-08-01

    We investigate the thermal, magnetic and rotational evolution of isolated neutron stars assuming that the dipolar magnetic field is confined to the crust. Our treatment, for the first time, uses a fully general relativistic formalism not only for the thermal but also for the magnetic part, and includes partial general relativistic effects in the rotational part. Due to the fact that the combined evolution depends crucially upon the compactness of the star, three different equations of state have been employed in the calculations. In the absence of general relativistic effects, while upon increasing compactness a decrease of the crust thickness takes place leading into an accelerating field decay, the inclusion of general relativistic effects intend to "decelerate this acceleration". As a consequence we find that, within the crustal field hypothesis, a given equation of state is compatible with the observed distribution of pulsar periods P and period derivative &mathaccent "705Frelax dot; provided the initial field strength and current location as well as the magnitude of the impurity content are appropriately constrained. Finally, we access the flexibility of the soft, medium and stiff classes of equations of state as candidates in describing the state of the matter in the neutron star interiors. The comparison of our model calculations with observations, together with the consideration of independent information about neutron star evolution, suggests that a not too soft equation of state describes neutron star interiors and its cooling proceeds along the `standard' scenario.

  6. Optimal Timing for Early Excision in a Deep Partial Thickness Porcine Burn Model.

    PubMed

    Toussaint, Jimmy; Chung, Won Taek; Mc Clain, Steve; Raut, Vivek; Singer, Adam J

    Many deep partial thickness burns require more than 3 weeks to heal resulting in disfiguring and dysfunctional scarring. Early excision of the eschar has been shown to improve outcomes in deep burns; however, the optimal timing of the excision remains controversial. We compared wound healing and scarring of deep partial thickness burns that were excised at different time points in a porcine model. Deep partial thickness burns (2.5 by 2.5 cm each) were created on the backs of six anesthetized pigs using a previously validated model. The burns were randomly assigned to excision at days 2, 4, or 7 using an electric dermatome. Full thickness 4-mm punch biopsies were obtained at several time points for determination of re-epithelialization and at day 28 for determination of scar depth. Digital imaging was used to calculate percentage wound contraction at day 28. There were no statistically significant differences in wound re-epithelialization at any of the studied time points. Scar depth and percentage wound contraction were also similar among the wounds excised at 2, 4, and 7 days (4.4 ± 1.1 mm vs 3.9 ± 1.1 mm vs 4.1 ± 1.2 mm and 52.9 ± 17.9% vs 52.6 ± 15.6% vs 52.5 ± 13.8%, respectively). Timing of eschar excision (at 2, 4, or 7 days) does not affect the rates of re-epithelialization and scarring in a deep partial thickness porcine burn model. Timing of eschar excision may not change outcomes if performed within the first 2 to 7 days after injury.

  7. The Combination of Preoperative Bone Marrow Lesions and Partial-Thickness Cartilage Loss Did Not Result in Inferior Outcomes After Medial Unicompartmental Knee Arthroplasty.

    PubMed

    Berend, Keith R; Lombardi, Adolph V; Jacobs, Cale A

    2017-10-01

    The purpose of this study is to compare patient-reported outcomes and revision rates between medial unicompartmental knee arthroplasty (UKA) patients based on the presence of medial bone marrow lesions (BMLs) and/or partial- vs full-thickness cartilage loss. BMLs were graded on preoperative magnetic resonance imaging (MRI) findings from 174 UKAs performed between 2009 and 2013 using the MRI Osteoarthritis Knee Score criteria by a single evaluator blinded to the patient's outcome. A second evaluator blinded to the MRI findings and postoperative outcomes assessed medial joint space present on both weight-bearing and valgus stress radiographs. Preoperative and postoperative Knee Society Knee Scores, Pain Scores, and Function Scores were then compared between 4 groups of patients: patients with BML with either partial- or full-thickness cartilage loss, and patients without BML with either partial- or full-thickness cartilage loss. In total, 152 of 174 (87%) patients had minimum 2-year follow-up. One patient in the no BML/full-thickness loss group was converted to total knee arthroplasty secondary to arthrofibrosis; however, there were no statistical differences in revision rate between the 4 groups as no other revisions were performed (P = .61). Similarly, preoperative and postoperative Knee Society Knee Scores, Pain Scores, and Function Scores did not differ between groups, nor did postoperative University of California, Los Angeles activity scores. Medial tibial BMLs were not associated with inferior outcomes, either in patients with partial- or full-thickness cartilage loss. Although the current results do not allow for the presence of preoperative BML to be considered an indication for UKA, these results definitively support that BMLs are not a contraindication for medial UKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Comparison of three different dressings for partial thickness burns in children: study protocol for a randomised controlled trial.

    PubMed

    Gee Kee, Emma; Kimble, Roy M; Cuttle, Leila; Stockton, Kellie

    2013-11-25

    In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤ 10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Australian New Zealand Clinical Trials Registry ACTRN12613000105741.

  9. Efficacy of platelet-rich plasma in arthroscopic repair of full-thickness rotator cuff tears: a meta-analysis.

    PubMed

    Cai, You-zhi; Zhang, Chi; Lin, Xiang-jin

    2015-12-01

    The use of platelet-rich plasma (PRP) is an innovative clinical therapy, especially in arthroscopic rotator cuff repair. The purpose of this study was to compare the clinical improvement and tendon-to-bone healing with and without PRP therapy in arthroscopic rotator cuff repair. A systematic search was done in the major medical databases to evaluate the studies using PRP therapy (PRP+) or with no PRP (PRP-) for the treatment of patients with rotator cuff tears. We reviewed clinical scores such as the Constant score, the American Shoulder and Elbow Surgeons score, the University of California at Los Angeles (UCLA) Shoulder Rating Scale, the Simple Shoulder Test, and the failure-to-heal rate by magnetic resonance imaging between PRP+ and PRP- groups. Five studies included in this review were used for a meta-analysis based on data availability. There were no statistically significant differences between PRP+ and PRP- groups for overall outcome scores (P > .05). However, the PRP+ group exhibited better healing rates postoperatively than the PRP- group (P = .03) in small/moderate full-thickness tears. The use of PRP therapy in full-thickness rotator cuff repairs showed no statistically significant difference compared with no PRP therapy in clinical outcome scores, but the failure-to-heal rate was significantly decreased when PRP was used for treatment of small-to-moderately sized tears. PRP therapy may improve tendon-to-bone healing in patients with small or moderate rotator cuff tears. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. The severity of the long head biceps tendinopathy in patients with chronic rotator cuff tears: macroscopic versus microscopic results.

    PubMed

    Wu, Po-Ting; Jou, I-Ming; Yang, Cheng-Chang; Lin, Chii-Jeng; Yang, Chyun-Yu; Su, Fong-Chin; Su, Wei-Ren

    2014-08-01

    This study investigated the histopathology of the long head of biceps (LHB) tendon and correlated the findings with the macroscopic appearances of the LHB and the size of rotator cuff tears (RCTs) in patients with chronic RCTs. We compared biopsy specimens from LHBs in 34 patients with chronic RCTs and grossly normal LHBs in 8 patients undergoing shoulder hemiarthroplasty (controls). Duration of preoperative symptoms, the severity of RCTs, and macroscopic appearance of LHBs were recorded, classified, and compared with the histologic grading and apoptosis index of terminal deoxynucleotide transferase-mediated biotin-deoxy uridine triphosphate nick-end labeling (TUNEL) assays of LHBs. In the RCT group, there were 8 partial-thickness tears with 5 macroscopic LHB lesions, 12 full-thickness tears with 8 macroscopic LHB lesions, and 14 massive tears with 13 macroscopic LHB lesions. There were 6 LHB subluxations. However, the macroscopic grading and the symptom duration were not correlated with the severity of the histology. In patients with massive tears, no matter what the macroscopic appearance of the LHB, the proportion of end-stage (grade 4) histologic LHB tendinopathy significantly increased (85.7%, P < .05) compared with patients with other types of RCTs. There was a consistently high incidence of advanced LHB histology (grade 3 or higher) in each classification of RCTs (75.0%-100.0%). The 8 patients in the control group showed milder histopathology (grade 1 or 2). The apoptosis index significantly increased as the tendinopathy progressed (P < .05). The macroscopic pathology of LHB may not fully reflect the severity of tendinopathy, and the coexisting size of RCTs plays a role in the severity of LHB tendinopathy. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. Impact of Platelet-Rich Plasma on Arthroscopic Repair of Small- to Medium-Sized Rotator Cuff Tears: A Randomized Controlled Trial.

    PubMed

    Holtby, Richard; Christakis, Monique; Maman, Eran; MacDermid, Joy C; Dwyer, Tim; Athwal, George S; Faber, Kenneth; Theodoropoulos, John; Woodhouse, Linda J; Razmjou, Helen

    2016-09-01

    Increased interest in using platelet-rich plasma (PRP) as an augment to rotator cuff repair warrants further investigation, particularly in smaller rotator cuff tears. To examine the effectiveness of PRP application in improving perioperative pain and function and promoting healing at 6 months after arthroscopic repair of small- or medium-sized rotator cuff tears. Randomized controlled trial; Level of evidence, 1. This was a double-blinded randomized controlled trial of patients undergoing arthroscopic repair of partial- or full-thickness rotator cuff tears of up to 3 cm who were observed for 6 months. Patients were randomized to either repair and PRP application (study group) or repair only (control group) groups. The patient-oriented outcome measures utilized were the visual analog scale (VAS), the Short Western Ontario Rotator Cuff Index (ShortWORC), the American Shoulder and Elbow Surgeons (ASES) form, and the Constant-Murley Score (CMS). Range of motion (ROM) and inflammatory and coagulation markers were measured before and after surgery. Magnetic resonance imaging was used at 6 months to assess retear and fatty infiltration rate. Eighty-two patients (41 males) with a mean age of 59 ± 8 years were enrolled; 41 patients were included in each group. Both the PRP and control groups showed a significant improvement in their pain level based on the VAS within the first 30 days (P < .0001), with the PRP group reporting less pain than the control group (P = .012), which was clinically significantly different from days 8 through 11. The PRP group reported taking less painkillers (P = .026) than the control group within the first 30 days. All outcome measure scores and ROM improved significantly after surgery (P < .0001), with no between-group differences. No differences were observed between groups in inflammatory or coagulation marker test results (P > .05), retear (14% vs 18% full retear; P = .44), or fatty infiltration rate (P = .08). The PRP biological augmentation for repair of small- to medium-sized rotator cuff tears has a short-term effect on perioperative pain without any significant impact on patient-oriented outcome measures or structural integrity of the repair compared with control group.

  12. Does partial tear repair of adjacent tendons improve the outcome of supraspinatus tendonfull-thickness tear reinsertion?

    PubMed

    Nich, C; Dhiaf, N; Di Schino, M; Augereau, B

    2014-11-01

    Partial tearing of the infraspinatus and/or subscapularis tendon(s) is frequently associated with supraspinatus full-thickness tears. However, limited data regarding its influence on supraspinatus surgical repair is available. Our aim was to assess the functional and anatomical outcomes of open repair of supraspinatus full-thickness tears combined with adjacent partial tearing, comparatively to a control. We retrospectively identified 22 patients (22 shoulders) with a partial tear, most of them being a delamination tear, of the infraspinatus and/or subscapularis tendons associated with a complete detachment of the supraspinatus tendon. Twenty-seven patients (27 shoulders) treated for an isolated complete detachment of the supraspinatus tendon by open repair served as controls. The mean age was 58 years. A proximalized trans-osseous reinsertion of the supraspinatus tendon was combined with a curettage-closure of the delamination tear. Patients were evaluated with standardized MRI at last follow-up. At a mean of 75-month follow-up, the presence of a partial tear of either infraspinatus or subscapularis, or both, did not influence function and healing rates of supraspinatus tendon repair. Conversely to the control, when a retear occurred, the functional score tended to worsen. Preoperatively, fatty muscular degeneration was more pronounced when a partial tear was present. Fatty degeneration worsened regardless of repair healing. Open reinsertion of a supraspinatus full-thickness tear associated with a thorough treatment of partial tear of adjacent tendons led to optimal functional and anatomical mid term outcomes. Our results suggest the presence of a partial tear of adjacent tendons could be associated with poorer function in case of supraspinatus tendon re-rupture. Level III case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  13. The Relationship Between Intraoperative Tear Dimensions and Postoperative Pain in 1624 Consecutive Arthroscopic Rotator Cuff Repairs.

    PubMed

    Yeo, Daniel Y T; Walton, Judie R; Lam, Patrick; Murrell, George A C

    2017-03-01

    Rotator cuff repair often results in significant pain postoperatively, the cause of which is undetermined. Purpose/Hypothesis: The aim of this study was to evaluate the relationship between rotator cuff tear area and postoperative pain in patients who had undergone arthroscopic rotator cuff repair. We hypothesized that larger tears would be more painful because of elevated repair tension at 1 week postoperatively but that smaller tears would be more painful because of a greater healing response, especially from 6 weeks postoperatively. Cohort study; Level of evidence, 3. A total of 1624 patients who underwent arthroscopic rotator cuff repair were included in this study. Exclusion criteria were moderate to severe osteoarthritis, isolated subscapularis repair, calcific tendinitis, synthetic patch repair, revision surgery, and retears on ultrasound at 6 months after surgery. Rotator cuff tears were subdivided into groups based on the tear size and retear rate found for each group. A modified L'Insalata questionnaire was given before surgery and at 1 week, 6 weeks, 3 months, and 6 months after surgery. Pearson and Spearman correlation coefficient tests were performed between rotator cuff tear areas and pain scores. Intraoperative rotator cuff tear areas did not correlate with pain scores preoperatively or at 1 week after surgery. A smaller tear area was associated with more frequent and severe pain with overhead activities, at rest, and during sleep as well as a poorer perceived overall shoulder condition at 6 weeks, 3 months, and 6 months after repair ( r = 0.11-0.23, P < .0001). Patients who were younger, had partial-thickness tears, and had occupational injuries experienced more pain postoperatively ( r = 0.10-0.28, P < .0001). Larger tears did not have more pain at 1 week after surgery. The retear rate was 7% in tears <2 cm 2 but reached 44% in tears >8 cm 2 . There were fewer retears with smaller tears, but they were more painful than large tears postoperatively from 6 weeks to 6 months after surgery. Smaller tears may heal more vigorously, causing more pain. Patients with smaller tears experienced more pain after rotator cuff repair compared with patients with larger tears. These findings are contrary to previous ideas about tear size and postoperative pain. Healing is likely a determinant of postoperative pain.

  14. Accounting for partiality in serial crystallography using ray-tracing principles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroon-Batenburg, Loes M. J., E-mail: l.m.j.kroon-batenburg@uu.nl; Schreurs, Antoine M. M.; Ravelli, Raimond B. G.

    Serial crystallography generates partial reflections from still diffraction images. Partialities are estimated with EVAL ray-tracing simulations, thereby improving merged reflection data to a similar quality as conventional rotation data. Serial crystallography generates ‘still’ diffraction data sets that are composed of single diffraction images obtained from a large number of crystals arbitrarily oriented in the X-ray beam. Estimation of the reflection partialities, which accounts for the expected observed fractions of diffraction intensities, has so far been problematic. In this paper, a method is derived for modelling the partialities by making use of the ray-tracing diffraction-integration method EVAL. The method estimates partialitiesmore » based on crystal mosaicity, beam divergence, wavelength dispersion, crystal size and the interference function, accounting for crystallite size. It is shown that modelling of each reflection by a distribution of interference-function weighted rays yields a ‘still’ Lorentz factor. Still data are compared with a conventional rotation data set collected from a single lysozyme crystal. Overall, the presented still integration method improves the data quality markedly. The R factor of the still data compared with the rotation data decreases from 26% using a Monte Carlo approach to 12% after applying the Lorentz correction, to 5.3% when estimating partialities by EVAL and finally to 4.7% after post-refinement. The merging R{sub int} factor of the still data improves from 105 to 56% but remains high. This suggests that the accuracy of the model parameters could be further improved. However, with a multiplicity of around 40 and an R{sub int} of ∼50% the merged still data approximate the quality of the rotation data. The presented integration method suitably accounts for the partiality of the observed intensities in still diffraction data, which is a critical step to improve data quality in serial crystallography.« less

  15. Cortical thickness measurement from magnetic resonance images using partial volume estimation

    NASA Astrophysics Data System (ADS)

    Zuluaga, Maria A.; Acosta, Oscar; Bourgeat, Pierrick; Hernández Hoyos, Marcela; Salvado, Olivier; Ourselin, Sébastien

    2008-03-01

    Measurement of the cortical thickness from 3D Magnetic Resonance Imaging (MRI) can aid diagnosis and longitudinal studies of a wide range of neurodegenerative diseases. We estimate the cortical thickness using a Laplacian approach whereby equipotentials analogous to layers of tissue are computed. The thickness is then obtained using an Eulerian approach where partial differential equations (PDE) are solved, avoiding the explicit tracing of trajectories along the streamlines gradient. This method has the advantage of being relatively fast and insure unique correspondence points between the inner and outer boundaries of the cortex. The original method is challenged when the thickness of the cortex is of the same order of magnitude as the image resolution since partial volume (PV) effect is not taken into account at the gray matter (GM) boundaries. We propose a novel way to take into account PV which improves substantially accuracy and robustness. We model PV by computing a mixture of pure Gaussian probability distributions and use this estimate to initialize the cortical thickness estimation. On synthetic phantoms experiments, the errors were divided by three while reproducibility was improved when the same patients was scanned three consecutive times.

  16. What happens to patients when we do not repair their cuff tears? Five-year rotator cuff quality-of-life index outcomes following nonoperative treatment of patients with full-thickness rotator cuff tears.

    PubMed

    Boorman, Richard S; More, Kristie D; Hollinshead, Robert M; Wiley, James P; Mohtadi, Nicholas G; Lo, Ian K Y; Brett, Kelly R

    2018-03-01

    The purpose of this study was to examine 5-year outcomes in a prospective cohort of patients previously enrolled in a nonoperative rotator cuff tear treatment program. Patients with chronic (>3 months), full-thickness rotator cuff tears (demonstrated on imaging) who were referred to 1 of 2 senior shoulder surgeons were enrolled in the study between October 2008 and September 2010. They participated in a comprehensive, nonoperative, home-based treatment program. After 3 months, the outcome in these patients was defined as "successful" or "failed." Patients in the successful group were essentially asymptomatic and did not require surgery. Patients in the failed group were symptomatic and consented to undergo surgical repair. All patients were followed up at 1 year, 2 years, and 5 or more years. At 5 or more years, all patients were contacted for follow-up; the response rate was 84%. Approximately 75% of patients remained successfully treated with nonoperative treatment at 5 years and reported a mean rotator cuff quality-of-life index score of 83 of 100 (SD, 16). Furthermore, between 2 and 5 years, only 3 patients who had previously been defined as having a successful outcome became more symptomatic and underwent surgical rotator cuff repair. Those in whom nonoperative treatment had failed and who underwent surgical repair had a mean rotator cuff quality-of-life index score of 89 (SD, 11) at 5-year follow-up. The operative and nonoperative groups at 5-year follow-up were not significantly different (P = .11). Nonoperative treatment is an effective and lasting option for many patients with a chronic, full-thickness rotator cuff tear. While some clinicians may argue that nonoperative treatment delays inevitable surgical repair, our study shows that patients can do very well over time. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Surface quality of unsaturated polyester resin processed via continuous multi-shot rotational molding

    NASA Astrophysics Data System (ADS)

    Ogila, K. O.; Yang, W.; Shao, M.; Tan, J.

    2017-05-01

    Unsaturated Polyester Resin is a versatile and cost efficient thermosetting plastic whose application in rotational molding is currently limited by its relatively high initial viscosity and heat of reaction. These material characteristics result in uneven material distribution, poor surface finish and imperfections in the moldings especially when large wall thicknesses are required. The current work attempts to remedy these shortcomings through the development of a continuous multi-shot system which adds predetermined loads of unsaturated polyester resin into a rotating mold at various intervals. As part of this system, a laboratory-scale uniaxial rotational molding machine was used to produce Unsaturated Polyester Resin moldings in single and double shots. Optimal processing conditions were determined through visual studies, three dimensional microscopic studies, thickness distribution analysis and Fourier Transform Infrared spectroscopy. Volume filling fractions of 0.049-0.065, second shot volumes of 0.5-0.75 from the first shot, rotational speeds of 15-20 rpm and temperatures of 30-50 °C resulted in moldings of suitable quality on both the inner and outer surfaces.

  18. On the rotation and pitching of flat plates

    NASA Astrophysics Data System (ADS)

    Jin, Yaqing; Ji, Sheng; Chamorro, Leonardo P.

    2016-11-01

    Wind tunnel experiments were performed to characterize the flow-induced rotation and pitching of various flat plates as a function of the thickness ratio, the location of the axis of rotation and turbulence levels. High-resolution telemetry, laser tachometer, and hotwire were used to get time series of the plates motions and the signature of the wake flow at a specific location. Results show that a minor axis offset can induce high-order modes in the plate rotation under low turbulence due to torque unbalance. The spectral decomposition of the flow velocity in the plate wake reveals the existence of a dominating high-frequency mode that corresponds to a static-like vortex shedding occurring at the maximum plate pitch, where the characteristic length scale is the projected width at maximum pitch. The plate thickness ratio shows inverse relation with the angular velocity. A simple model is derived to explain the linear relation between pitching frequency and wind speed. The spectra of the plate rotation show nonlinear relation with the incoming turbulence, and the dominating role of the generated vortices in the plate motions.

  19. Randomized Controlled Trial of Polyhexanide/Betaine Gel Versus Silver Sulfadiazine for Partial-Thickness Burn Treatment.

    PubMed

    Wattanaploy, Saruta; Chinaroonchai, Kusuma; Namviriyachote, Nantaporn; Muangman, Pornprom

    2017-03-01

    Silver sulfadiazine is commonly used in the treatment of partial-thickness burns, but it sometimes forms pseudo-eschar and delays wound healing. Polyhexanide/betaine gel, a new wound cleansing and moisturizing product, has some advantages in removing biofilm and promotes wound healing. This study was designed to compare clinical efficacy of polyhexanide/betaine gel with silver sulfadiazine in partial-thickness burn treatment. From September 2013 to May 2015, 46 adult patients with partial-thickness burn ≥10% total body surface area that were admitted to the Burn Unit of Siriraj Hospital within 48 hours after injury were randomly allocated into 2 groups. One group was treated with polyhexanide/betaine gel, and the other group was treated with silver sulfadiazine. Both groups received daily dressing changes and the same standard care given to patients with burns in this center. Healing times in the polyhexanide/betaine gel group and silver sulfadiazine group were 17.8 ± 2.2 days and 18.8 ± 2.1 days, respectively ( P value .13). There were no significant differences in healing times, infection rates, bacterial colonization rates, and treatment cost in both groups. The pain score of the polyhexanide/betaine gel group was significantly less than the silver sulfadiazine group at 4 to 9 days after treatment ( P < .001). The satisfactory assessment result of the polyhexanide/betaine gel group was better than that in the silver sulfadiazine group. These data indicate the need for adequately designed studies to elicit the full potential of polyhexanide gel as a wound dressing for partial-thickness burn wounds.

  20. US appearance of partial-thickness supraspinatus tendon tears: Application of the string theory. Pictorial essay.

    PubMed

    Guerini, H; Fermand, M; Godefroy, D; Feydy, A; Chevrot, A; Morvan, G; Gault, N; Drapé, J L

    2012-02-01

    The supraspinatus tendon is composed of 5 different layers consisting of intertwining bundles. On a front portion of the tendon, the layers become coated bundles which insert on the trochanter. At the insertion, the superficial or bursal surface of the tendon corresponding to the tendon fibers in contact with the subacromial bursa can be distinguished from the deep surface corresponding to the fibers in contact with the glenohumeral joint. A tendon tear may involve partial or total disruption of the tendon fibers and is called full-thickness tear if it affects the entire tendon, and partial-thickness tear if it involves only part of the tendon. Partial-thickness tears of the supraspinatus tendon include lesions of the superficial, deep and central surface or tendon delamination.A contrast enhanced examination requires injection of contrast agent into the joint (arthrography followed by computed tomography (CT) or magnetic resonance imaging (MRI)) to study the deep surface, and injection into the subacromial bursa (bursography followed by CT) to study the superficial surface. MRI and ultrasound (US) examination allow the study of these different tendon layers without the use of contrast agent (which is not possible at CT).

  1. Influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage restorations.

    PubMed

    Bakeman, E M; Rego, N; Chaiyabutr, Y; Kois, J C

    2015-01-01

    This study evaluated the influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage ceramic restorations. Forty extracted molars were allocated into four groups (n=10) to test for two variables: 1) the thickness of ceramic (1 mm or 2 mm) and 2) the ceramic materials (a lithium disilicate glass-ceramic [IPS e.max] or leucite-reinforced glass ceramic [IPS Empress]). All ceramic restorations were luted with resin cement (Variolink II) on the prepared teeth. These luted specimens were loaded to failure in a universal testing machine, in the compression mode, with a crosshead speed of 1.0 mm/min. The data were analyzed using two-way analysis of variance and the Tukey Honestly Significantly Different multiple comparison test (α =0.05). The fracture resistance revealed a significant effect for materials (p<0.001); however, the thickness of ceramic was not significant (p=0.074), and the interaction between the thickness of ceramic and the materials was not significant (p=0.406). Mean (standard deviation) fracture resistance values were as follows: a 2-mm thickness of a lithium disilicate bonded to tooth structure (2505 [401] N) revealed a significantly higher fracture resistance than did a 1-mm thickness of leucite-reinforced (1569 [452] N) and a 2-mm thickness of leucite-reinforced ceramic bonded to tooth structure (1716 [436] N) (p<0.05). There was no significant difference in fracture resistance values between a lithium disilicate ceramic at 1-mm thickness (2105 [567] N) and at 2-mm thickness. Using a lithium disilicate glass ceramic for partial coverage restoration significantly improved fracture resistance compared to using a leucite-reinforced glass ceramic. The thickness of ceramic had no significant effect on fracture resistance when the ceramics were bonded to the underlying tooth structure.

  2. Sustainable antimicrobial effect of silver sulfadiazine-loaded nanosheets on infection in a mouse model of partial-thickness burn injury.

    PubMed

    Ito, Keisuke; Saito, Akihiro; Fujie, Toshinori; Nishiwaki, Keisuke; Miyazaki, Hiromi; Kinoshita, Manabu; Saitoh, Daizoh; Ohtsubo, Shinya; Takeoka, Shinji

    2015-09-01

    Partial-thickness burn injury has the potential for reepithelialization and heals within 3weeks. If the wound is infected by bacteria before reepithelization, however, the depth of disruption increases and the lesion easily progresses to the full-thickness dermal layers. In the treatment of partial-thickness burn injury, it is important to prevent the wound area from bacterial infection with an antimicrobial dressing. Here, we have tested the antimicrobial properties of polymeric ultra-thin films composed of poly(lactic acid) (termed "PLA nanosheets"), which have high flexibility, adhesive strength and transparency, and silver sulfadiazine (AgSD), which exhibits antimicrobial efficacy. The AgSD-loaded nanosheet released Ag(+) for more than 3days, and exerted antimicrobial efficacy against methicillin-resistant Staphylococcus aureus (MRSA) in an in vitro Kirby-Bauer test. By contrast, a cell viability assay indicated that the dose of AgSD used in the PLA nanosheets did not show significant cytotoxicity toward fibroblasts. In vivo evaluation using a mouse model of infection in a partial-thickness burn wound demonstrated that the nanosheet significantly reduced the number of MRSA bacteria on the lesion (more than 10(5)-fold) and suppressed the inflammatory reaction, thereby preventing a protracted wound healing process. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  3. User's guide to computer programs JET 5A and CIVM-JET 5B to calculate the large elastic-plastic dynamically-induced deformations of multilayer partial and/or complete structural rings

    NASA Technical Reports Server (NTRS)

    Wu, R. W. H.; Stagliano, T. R.; Witmer, E. A.; Spilker, R. L.

    1978-01-01

    These structural ring deflections lie essentially in one plane and, hence, are called two-dimensional (2-d). The structural rings may be complete or partial; the former may be regarded as representing a fragment containment ring while the latter may be viewed as a 2-d fragment-deflector structure. These two types of rings may be either free or supported in various ways (pinned-fixed, locally clamped, elastic-foundation supported, mounting-bracket supported, etc.). The initial geometry of each ring may be circular or arbitrarily curved; uniform-thickness or variable-thickness rings may be analyzed. Strain-hardening and strain-rate effects of initially-isotropic material are taken into account. An approximate analysis utilizing kinetic energy and momentum conservation relations is used to predict the after-impact velocities of each fragment and of the impact-affected region of the ring; this procedure is termed the collision-imparted velocity method (CIVM) and is used in the CIVM-JET 5 B program. This imparted-velocity information is used in conjunction with a finite-element structural response computation code to predict the transient, large-deflection, elastic-plastic responses of the ring. Similarly, the equations of motion of each fragment are solved in small steps in time. Provisions are made in the CIVM-JET 5B code to analyze structural ring response to impact attack by from 1 to 3 fragments, each with its own size, mass, translational velocity components, and rotational velocity. The effects of friction between each fragment and the impacted ring are included.

  4. Do postoperative platelet-rich plasma injections accelerate early tendon healing and functional recovery after arthroscopic supraspinatus repair? A randomized controlled trial.

    PubMed

    Wang, Allan; McCann, Philip; Colliver, Jess; Koh, Eamon; Ackland, Timothy; Joss, Brendan; Zheng, Minghao; Breidahl, Bill

    2015-06-01

    Tendon-bone healing after rotator cuff repair directly correlates with a successful outcome. Biological therapies that elevate local growth-factor concentrations may potentiate healing after surgery. To ascertain whether postoperative and repeated application of platelet-rich plasma (PRP) to the tendon repair site improves early tendon healing and enhances early functional recovery after double-row arthroscopic supraspinatus repair. Randomized controlled trial; Level of evidence, 1. A total of 60 patients underwent arthroscopic double-row supraspinatus tendon repair. After randomization, half the patients received 2 ultrasound-guided injections of PRP to the repair site at postoperative days 7 and 14. Early structural healing was assessed with MRI at 16 weeks, and cuff appearances were graded according to the Sugaya classification. Functional scores were recorded with the Oxford Shoulder Score; Quick Disability of the Arm, Shoulder and Hand; visual analog scale for pain; and Short Form-12 quality-of-life score both preoperatively and at postoperative weeks 6, 12, and 16; isokinetic strength and active range of motion were measured at 16 weeks. PRP treatment did not improve early functional recovery, range of motion, or strength or influence pain scores at any time point after arthroscopic supraspinatus repair. There was no difference in structural integrity of the supraspinatus repair on MRI between the PRP group (0% full-thickness retear; 23% partial tear; 77% intact) and the control group (7% full-thickness retear; 23% partial tear; 70% intact) at 16 weeks postoperatively (P = .35). After arthroscopic supraspinatus tendon repair, image-guided PRP treatment on 2 occasions does not improve early tendon-bone healing or functional recovery. © 2015 The Author(s).

  5. Radiative Heating Methodology for the Huygens Probe

    NASA Technical Reports Server (NTRS)

    Johnston, Christopher O.; Hollis, Brian R.; Sutton, Kenneth

    2007-01-01

    The radiative heating environment for the Huygens probe near peak heating conditions for Titan entry is investigated in this paper. The task of calculating the radiation-coupled flowfield, accounting for non-Boltzmann and non-optically thin radiation, is simplified to a rapid yet accurate calculation. This is achieved by using the viscous-shock layer (VSL) technique for the stagnation-line flowfield calculation and a modified smeared rotational band (SRB) model for the radiation calculation. These two methods provide a computationally efficient alternative to a Navier-Stokes flowfield and line-by-line radiation calculation. The results of the VSL technique are shown to provide an excellent comparison with the Navier-Stokes results of previous studies. It is shown that a conventional SRB approach is inadequate for the partially optically-thick conditions present in the Huygens shock-layer around the peak heating trajectory points. A simple modification is proposed to the SRB model that improves its accuracy in these partially optically-thick conditions. This modified approach, labeled herein as SRBC, is compared throughout this study with a detailed line-by-line (LBL) calculation and is shown to compare within 5% in all cases. The SRBC method requires many orders-of-magnitude less computational time than the LBL method, which makes it ideal for coupling to the flowfield. The application of a collisional-radiative (CR) model for determining the population of the CN electronic states, which govern the radiation for Huygens entry, is discussed and applied. The non-local absorption term in the CR model is formulated in terms of an escape factor, which is then curve-fit with temperature. Although the curve-fit is an approximation, it is shown to compare well with the exact escape factor calculation, which requires a computationally intensive iteration procedure.

  6. Synthesis and Characterization of Hexagonal Boron Nitride as a Gate Dielectric

    PubMed Central

    Jang, Sung Kyu; Youn, Jiyoun; Song, Young Jae; Lee, Sungjoo

    2016-01-01

    Two different growth modes of large-area hexagonal boron nitride (h-BN) film, a conventional chemical vapor deposition (CVD) growth mode and a high-pressure CVD growth mode, were compared as a function of the precursor partial pressure. Conventional self-limited CVD growth was obtained below a critical partial pressure of the borazine precursor, whereas a thick h-BN layer (thicker than a critical thickness of 10 nm) was grown beyond a critical partial pressure. An interesting coincidence of a critical thickness of 10 nm was identified in both the CVD growth behavior and in the breakdown electric field strength and leakage current mechanism, indicating that the electrical properties of the CVD h-BN film depended significantly on the film growth mode and the resultant film quality. PMID:27458024

  7. Electro-physical properties of superconducting ceramic thick film prepared by partial melting method.

    PubMed

    Lee, Sang Heon

    2013-05-01

    BiSrCaCuO superconductor thick films were prepared at several curing temperatures, and their electro-physical properties were determined to find an optimum fabrication conditions. Critical temperatures of the superconductors were decreased with increasing melting temperature, which was related to the amount of equilibrium phases of the superconducting materials with temperature. The critical temperature of BiSrCaCuO bulk and thick film superconductors were 107 K and 96 K, respectively. The variation of susceptibility of the superconductor thick film formed at 950 degrees C had multi-step-type curve for 70 G externally applied field, whereas, a superconductor thick film formed at 885 degrees C had a single step-type curve like a bulk BiSrCaCuO ceramic superconductor in the temperature-susceptibility curves. A partial melting at 865 degrees C is one of optimum conditions for making a superconductor thick film with a relatively homogeneous phase.

  8. METHOD OF APPLYING METALLIC COATINGS

    DOEpatents

    Robinson, J.W.; Eubank, L.D.

    1961-08-01

    A method for applying a protective coating to a uranium rod is described. The steps include preheating the unanium rod to the coating temperature, placement of the rod between two rotating rollers, pouring a coating metal such as aluminum-silicon in molten form between one of the rotating rollers and the uranium rod, and rotating the rollers continually until the coating is built up to the desired thickness. (AEC)

  9. Arthroscopic transtendinous repair of articular-sided pasta (partial articular supraspinatus tendon avulsion) injury.

    PubMed

    Wang, Yi; Lu, Liangyu; Lu, Zhe; Xiao, Lei; Kang, Yifan; Wang, Zimin

    2015-01-01

    To evaluate clinical efficacy of arthroscopic transtendinous repair of partial articular-sided PASTA (partial articular supraspinatus tendon avulsion) injury. From February 2011 to July 2014, 12 cases of PASTA, aged 29 to 72 years with an average of 52.9 ± 13.3 years, were treated arthoscopically. To repair PASTA, articular-sided rotator cuff tear was explored, injury site was punctured and labeled with PDS absorbable monofilament suture (Ethicon, Somerville, NJ, USA) suture, subacromial bursa was cleaned up with acromioplasty, and integrity of bursa-side rotator cuff was assessed. Then with arthroscope in glenohumeral joint, footprint of the bursa-side supraspinatus tendon was preserved, rivets were introduced into the joint through supraspinatus tendon, joint-side partial tear was sutured, and anatomical reconstruction of the rotator cuff footprint was established. The patients were followed up post-operatively for 12-36 months, average 22 ± 7.3 months. The clinical outcomes were emulated with ASES (American Shoulder and Elbow Surgeons) Shoulder Score system and UCLA (University of California at Los Angeles) Shoulder rating scale. The post-operative ASES score was 89.7 ± 5.6, higher than the pre-operative one 49.8 ± 9.8 (t = 12.25, P <0.0001). While UCLA scale increased from the pre-operative 17.3, ± 3.3 to the post-operative 30.4 ± 3.2 points (t = 9.87, P <0.0001), with a satisfaction rate of 11/12 (91.7%). Trans-tendon repair is ideal for PASTA with advantage of maximal preservation of the normal rotator cuff tissue, anatomical reconstruction of the rotator cuff footprint and stable fixation of tendon-bone interface.

  10. Effect of 1partial thickness actuation on stress concentration reduction near a hole

    NASA Technical Reports Server (NTRS)

    Sensharma, P. K.; Kadivar, M. H.; Haftka, R. T.

    1994-01-01

    Recently, there has been much interest in adaptive structures that can respond to a varying environment by changing their properties. Piezoelectric materials and shape memory alloys (SMA) are often used as partial thickness actuators to create such adaptivity by applied energy, usually electric curent. These actuators can be used to inducce strains in a structure and reduce stresses in regions of high stress concentration. Two of the present authors show that axisymmetric actuation strains applied troughout the thickness of a plate with a hole can reduce the stress concentration factor (SCF) in an isotropic plate from 3 to 2. However, in most cases actuators are expected to be bonded to or embedded in the plate, so that the actuation strains are applied in the actuators and not directly in the plate. The objective of this note is to show that such partial-thickness actuation cannot be used to reduce the stress concentration factor with axisymmetric actuations strain distribution.

  11. Effect of Rotational Speed on Microstructure and Mechanical Properties of Refill Friction Stir Spot Welded 2024 Al Alloy

    NASA Astrophysics Data System (ADS)

    Li, Zhengwei; Gao, Shuangsheng; Ji, Shude; Yue, Yumei; Chai, Peng

    2016-04-01

    Refill friction stir spot welding (RFSSW) was successfully used to weld alclad 2024 aluminum alloy with different thicknesses. Effects of tool rotational speed on the weld formation, microstructure, and mechanical properties of the RFSSW welds were mainly discussed. Results show that keyhole is successfully refilled and welding defects such as flash, annular groove, and material adhesion can be observed. A bright contrast bonding ligament is found embedded in the weld and it is thicker in the center. Defects of hook, void, lack of mixing, and incomplete refilling can be found at the thermo-mechanically affected zone/stir zone (TMAZ/SZ) interface, which can be attributed to weak metallurgical bonding effect. With increasing the tool rotational speed, thickness of the bonding ligament decreases, grains in the SZ coarsen, hardness of the SZ decreases, and lap shear load of the welds decreases. When changing the rotating speed, impact strength shows rather complicated variation trend.

  12. Thin-film magnetless Faraday rotators for compact heterogeneous integrated optical isolators

    NASA Astrophysics Data System (ADS)

    Karki, Dolendra; Stenger, Vincent; Pollick, Andrea; Levy, Miguel

    2017-06-01

    This report describes the fabrication, characterization, and transfer of ultra-compact thin-film magnetless Faraday rotators to silicon photonic substrates. Thin films of magnetization latching bismuth-substituted rare-earth iron garnets were produced from commercially available materials by mechanical lapping, dice polishing, and crystal-ion-slicing. Eleven- μ m -thick films were shown to retain the 45 ° Faraday rotation of the bulk material to within 2 ° at 1.55 μ m wavelength without re-poling. Anti-reflection coated films evince 0.09 dB insertion loses and better than -20 dB extinction ratios. Lower extinction ratios than the bulk are ascribed to multimode propagation. Significantly larger extinction ratios are predicted for single-mode waveguides. Faraday rotation, extinction ratios, and insertion loss tests on He-ion implanted slab waveguides of the same material yielded similar results. The work culminated with bond alignment and transfer of 7 μ m -thick crystal-ion-sliced 50 × 480 μ m 2 films onto silicon photonic substrates.

  13. Effect of rotating electric field on 3D complex (dusty) plasma

    NASA Astrophysics Data System (ADS)

    Wörner, L.; Nosenko, V.; Ivlev, A. V.; Zhdanov, S. K.; Thomas, H. M.; Morfill, G. E.; Kroll, M.; Schablinski, J.; Block, D.

    2011-06-01

    The effect of rotating electric field on 3D particle clusters suspended in rf plasma was studied experimentally. Spheroidal clusters were suspended inside a glass box mounted on the lower horizontal rf electrode, with gravity partially balanced by thermophoretic force. Clusters rotated in the horizontal plane, in response to rotating electric field that was created inside the box using conducting coating on its inner surfaces ("rotating wall" technique). Cluster rotation was always in the direction of applied field and had a shear in the vertical direction. The angular speed of rotation was 104-107 times lower than applied frequency. The experiment is compared to a recent theory.

  14. The rotation of cellulose synthase trajectories is microtubule dependent and influences the texture of epidermal cell walls in Arabidopsis hypocotyls.

    PubMed

    Chan, Jordi; Crowell, Elizabeth; Eder, Magdalena; Calder, Grant; Bunnewell, Susan; Findlay, Kim; Vernhettes, Samantha; Höfte, Herman; Lloyd, Clive

    2010-10-15

    Plant shoots have thick, polylamellate outer epidermal walls based on crossed layers of cellulose microfibrils, but the involvement of microtubules in such wall lamellation is unclear. Recently, using a long-term movie system in which Arabidopsis seedlings were grown in a biochamber, the tracks along which cortical microtubules move were shown to undergo slow rotary movements over the outer surface of hypocotyl epidermal cells. Because microtubules are known to guide cellulose synthases over the short term, we hypothesised that this previously unsuspected microtubule rotation could, over the longer term, help explain the cross-ply structure of the outer epidermal wall. Here, we test that hypothesis using Arabidopsis plants expressing the cellulose synthase GFP-CESA3 and show that cellulose synthase trajectories do rotate over several hours. Neither microtubule-stabilising taxol nor microtubule-depolymerising oryzalin affected the linear rate of GFP-CESA3 movement, but both stopped the rotation of cellulose synthase tracks. Transmission electron microscopy revealed that drug-induced suppression of rotation alters the lamellation pattern, resulting in a thick monotonous wall layer. We conclude that microtubule rotation, rather than any hypothetical mechanism for wall self-assembly, has an essential role in developing cross-ply wall texture.

  15. Comparison of three different dressings for partial thickness burns in children: study protocol for a randomised controlled trial

    PubMed Central

    2013-01-01

    Background In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Methods/Design Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. Discussion The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12613000105741 PMID:24274190

  16. Partial polarizer filter

    NASA Technical Reports Server (NTRS)

    Title, A. M. (Inventor)

    1978-01-01

    A birefringent filter module comprises, in seriatum. (1) an entrance polarizer, (2) a first birefringent crystal responsive to optical energy exiting the entrance polarizer, (3) a partial polarizer responsive to optical energy exiting the first polarizer, (4) a second birefringent crystal responsive to optical energy exiting the partial polarizer, and (5) an exit polarizer. The first and second birefringent crystals have fast axes disposed + or -45 deg from the high transmitivity direction of the partial polarizer. Preferably, the second crystal has a length 1/2 that of the first crystal and the high transmitivity direction of the partial polarizer is nine times as great as the low transmitivity direction. To provide tuning, the polarizations of the energy entering the first crystal and leaving the second crystal are varied by either rotating the entrance and exit polarizers, or by sandwiching the entrance and exit polarizers between pairs of half wave plates that are rotated relative to the polarizers. A plurality of the filter modules may be cascaded.

  17. Theoretical axial wall angulation for rotational resistance form in an experimental-fixed partial denture

    PubMed Central

    2017-01-01

    PURPOSE The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. MATERIALS AND METHODS Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. RESULTS Low levels of vertical wall taper, ≤ 10-degrees, were needed to resist rotational displacement in all wall height categories; 2–to–6–degrees is generally considered ideal, with 7–to–10–degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. CONCLUSION The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form. PMID:28874995

  18. New clues on the interior of Titan from its rotation state

    NASA Astrophysics Data System (ADS)

    Noyelles, Benoît; Nimmo, Francis

    2014-07-01

    The Saturnian satellite Titan is one of the main targets of the Cassini-Huygens mission, which revealed in particular Titan's shape, gravity field, and rotation state. The shape and gravity field suggest that Titan is not in hydrostatic equilibrium, that it has a global subsurface ocean, and that its ice shell is both rigid (at tidal periods) and of variable thickness. The rotational state of Titan consists of an expected synchronous rotation rate and an unexpectedly high obliquity (0.3○) explained by Baland et al. (2011) to be a resonant behavior. We here combine a realistic model of the ice shell and interior and a 6-degrees of freedom rotational model, in which the librations, obliquity and polar motion of the rigid core and of the shell are modelled, to constrain the structure of Titan from the observations. We consider the gravitational pull of Saturn on the 2 rigid layers, the gravitational coupling between them, and the pressure coupling at the liquid-solid interfaces. We confirm the influence of the resonance found by Baland et al., that affects between 10 and 13% of the possible Titans. It is due to the 29.5-year periodic annual forcing. The resonant Titans can be obtained in situations in which a mass anomaly at the shell-ocean boundary (bottom loading) is from 80 to 92% compensated. This suggests a 250 to 280 km thick ocean below a 130 to 140 km thick shell, and is consistent with the degree-3 analysis of Hemingway 26 et al. (2013).

  19. Rotational glenohumeral adaptations are associated with shoulder pathology in professional male handball players.

    PubMed

    Lubiatowski, Przemyslaw; Kaczmarek, Piotr; Cisowski, Pawel; Breborowicz, Ewa; Grygorowicz, Monika; Dzianach, Marcin; Krupecki, Tomasz; Laver, Lior; Romanowski, Leszek

    2018-01-01

    Glenohumeral range of motion adaptations may affect throwing athletes and contribute to shoulder injury. The purpose of this study was to evaluate shoulder rotation deficits among elite professional handball players and its correlation to the presence of shoulder pain and morphological changes. Eighty-seven elite professional handball players and 41 healthy non-athlete volunteers participated in the study. Evaluations included measurement of range of internal and external rotation, total arch of motion, identification of shoulder pain and ultrasound scan for diagnosis of rotator cuff tears and internal impingement. Glenohumeral rotational deficits (>20-25°) were found among 11 players group (13%). The throwing shoulders in the players group showed a decrease in internal rotation and an increase in external rotation with significantly larger ranges among players compared to the non-athlete group. Internal rotation deficit >20° was associated with higher incidence of shoulder pain among players. Both internal rotation deficits (>25°) and total arch of motion deficit (>20°) co-existed with higher incidence of internal impingement. Shoulder pain was common (36/97-41%) and was associated with decreased external rotation and total arch of motion. Internal impingement (found in 13/87-15%) correlated with decreased rotation ranges and a greater deficit in total arch of motion, whereas higher gain in external rotation correlated with a partial rotator cuff tear (found in 12/87-14%). Shoulder pathologies and problems commonly affected the group of handball players. Greater glenohumeral rotational deficits in throwing shoulders of handball players correlate with shoulder pain and internal impingement, while increased external rotation with partial rotator cuff tears. Such deficits affect 13% of the athlete population. Major clinical relevance of the study is to monitor handball players' shoulders both clinically and by proper imaging. Evaluation of range of rotation seems to identify shoulders at risk of the pathology. Cross-Sectional study with control group, Level II.

  20. Combined V-Y Fasciocutaneous Advancement and Gluteus Maximus Muscle Rotational Flaps for Treating Sacral Sores

    PubMed Central

    Choi, Eun Jeong; Moon, Suk Ho; Lee, Yoon Jae

    2016-01-01

    The sacral area is the most common site of pressure sore in bed-ridden patients. Though many treatment methods have been proposed, a musculocutaneous flap using the gluteus muscles or a fasciocutaneous flap is the most popular surgical option. Here, we propose a new method that combines the benefits of these 2 methods: combined V-Y fasciocutaneous advancement and gluteus maximus muscle rotational flaps. A retrospective review was performed for 13 patients who underwent this new procedure from March 2011 to December 2013. Patients' age, sex, accompanying diseases, follow-up duration, surgical details, complications, and recurrence were documented. Computed tomography was performed postoperatively at 2 to 4 weeks and again at 4 to 6 months to identify the thickness and volume of the rotational muscle portion. After surgery, all patients healed within 1 month; 3 patients experienced minor complications. The average follow-up period was 13.6 months, during which time 1 patient had a recurrence (recurrence rate, 7.7%). Average thickness of the rotated muscle was 9.43 mm at 2 to 4 weeks postoperatively and 9.22 mm at 4 to 6 months postoperatively (p = 0.087). Muscle thickness had not decreased, and muscle volume was relatively maintained. This modified method is relatively simple and easy for reconstructing sacral sores, provides sufficient padding, and has little muscle donor-site morbidity. PMID:27366755

  1. Non-Darcian flow to a partially penetrating well in a confined aquifer with a finite-thickness skin

    NASA Astrophysics Data System (ADS)

    Feng, Qinggao; Wen, Zhang

    2016-08-01

    Non-Darcian flow to a partially penetrating well in a confined aquifer with a finite-thickness skin was investigated. The Izbash equation is used to describe the non-Darcian flow in the horizontal direction, and the vertical flow is described as Darcian. The solution for the newly developed non-Darcian flow model can be obtained by applying the linearization procedure in conjunction with the Laplace transform and the finite Fourier cosine transform. The flow model combines the effects of the non-Darcian flow, partial penetration of the well, and the finite thickness of the well skin. The results show that the depression cone spread is larger for the Darcian flow than for the non-Darcian flow. The drawdowns within the skin zone for a fully penetrating well are smaller than those for the partially penetrating well. The skin type and skin thickness have great impact on the drawdown in the skin zone, while they have little influence on drawdown in the formation zone. The sensitivity analysis indicates that the drawdown in the formation zone is sensitive to the power index ( n), the length of well screen ( w), the apparent radial hydraulic conductivity of the formation zone ( K r2), and the specific storage of the formation zone ( S s2) at early times, and it is very sensitive to the parameters n, w and K r2 at late times, especially to n, while it is not sensitive to the skin thickness ( r s).

  2. Electrorotation of a metal sphere immersed in an electrolyte of finite Debye length.

    PubMed

    García-Sánchez, Pablo; Ramos, Antonio

    2015-11-01

    We theoretically study the rotation induced on a metal sphere immersed in an electrolyte and subjected to a rotating electric field. The rotation arises from the interaction of the field with the electric charges induced at the metal-electrolyte interface, i.e., the induced electrical double layer (EDL). Particle rotation is due to the torque on the induced dipole, and also from induced-charge electro-osmostic flow (ICEO). The interaction of the electric field with the induced dipole on the system gives rise to counterfield rotation, i.e., the direction opposite to the rotation of the electric field. ICEO generates co-field rotation of the sphere. For thin EDL, ICEO generates negligible rotation. For increasing size of EDL, co-field rotation appears and, in the limit of very thick EDL, it compensates the counter-field rotation induced by the electrical torque. We also report computations of the rotating fluid velocity field around the sphere.

  3. Standardization of deep partial-thickness scald burns in C57BL/6 mice

    PubMed Central

    Medina, Jorge L; Fourcaudot, Andrea B; Sebastian, Eliza A; Shankar, Ravi; Brown, Ammon W; Leung, Kai P

    2018-01-01

    Mouse burn models are used to understand the wound healing process and having a reproducible model is important. The different protocols used by researchers can lead to differences in depth of partial-thickness burn wounds. Additionally, standardizing a protocol for mouse burns in the laboratory for one strain may result in substantially different results in other strains. In our current study we describe the model development of a deep partial-thickness burn in C57BL/6 mice using hot water scalding as the source of thermal injury. As part of our model development we designed a template with specifications to allow for even contact of bare mouse skin (2×3 cm) with hot water while protecting the rest of the mouse. Burn depth was evaluated with H&E, Masson’s trichrome, and TUNEL staining. Final results were validated with pathology analysis. A water temperature of 54°C with a scalding time of 20 seconds produced consistent deep partial-thickness burns with available equipment described. Other than temperature and time, factors such as template materials and cooling steps after the burn could affect the uniformity of the burns. These findings are useful to burn research by providing some key parameters essential for researchers to simplify the development of their own mouse burn models. PMID:29755839

  4. Orofacial contracture management outcomes following partial thickness facial burns.

    PubMed

    Clayton, N A; Ward, E C; Maitz, P K M

    2015-09-01

    To examine clinical outcomes following non-surgical exercise for contracture management post partial thickness orofacial burn. A cohort of 229 patients with partial thickness orofacial burn was recruited over 3 years. Orofacial contracture management combining exercise and stretching was initiated within 48h of admission and continued until functional goals were consistently achieved. A second cohort of 120 healthy controls was recruited for normative comparison. Vertical and horizontal mouth opening measures were recorded at the start and completion of orofacial intervention for patients and once only for controls. At commencement of intervention, participants with orofacial burns had significantly (p<0.001) reduced vertical and horizontal mouth opening. Treatment duration averaged 30.7 days (SD=52.3). Post treatment significant (p<0.001) improvements in vertical and horizontal opening were noted. At treatment conclusion, a significant (p<0.01) difference remained between the burns cohort and control group for vertical mouth opening, though horizontal mouth opening was now statistically comparable to the controls. This study supports positive outcomes following orofacial contracture management for patients with partial thickness orofacial burn. Despite this, some functional loss remained with patients demonstrating persistent reduced vertical mouth opening at conclusion of treatment compared to their healthy counterparts. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  5. Negative pressure wound therapy for partial-thickness burns.

    PubMed

    Dumville, Jo C; Munson, Christopher; Christie, Janice

    2014-12-15

    A burn wound is a complex and evolving injury, with both local and systemic consequences. Burn treatments include a variety of dressings, as well as newer strategies, such as negative pressure wound therapy (NPWT), which, by means of a suction force that drains excess fluids from the burn, tries to promote the wound healing process and minimise progression of the burn wound. To assess the effectiveness of NPWT for people with partial-thickness burns. We searched the Cochrane Wounds Group Specialised Register (searched 04 September 2014); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 8). All randomised controlled trials (RCTs) and controlled clinical trials (CCTs) that evaluated the safety and effectiveness of NPWT for partial-thickness burns. Two review authors used standardised forms, and extracted the data independently. We assessed each trial for risk of bias, and resolved differences by discussion. One RCT, that was an interim report, satisfied the inclusion criteria. We undertook a narrative synthesis of results, as the absence of data and poor reporting precluded us from carrying out any formal statistical analysis. The trial was at high risk of bias. There was not enough evidence available to permit any conclusions to be drawn regarding the use of NPWT for treatment of partial-thickness burn wounds.

  6. Effectiveness of Physical Therapy in Treating Atraumatic Full Thickness Rotator Cuff Tears. A Multicenter Prospective Cohort Study

    PubMed Central

    Kuhn, John E.; Dunn, Warren R.; Sanders, Rosemary; An, Qi; Baumgarten, Keith M.; Bishop, Julie Y.; Brophy, Robert H.; Carey, James L.; Holloway, Brian G.; Jones, Grant L.; Ma, C. Benjamin; Marx, Robert G.; McCarty, Eric C.; Poddar, Sourav K.; Smith, Matthew V.; Spencer, Edwin E.; Vidal, Armando F.; Wolf, Brian R.; Wright, Rick W.

    2013-01-01

    Purpose To assess the effectiveness of a specific non-operative physical therapy program in treating atraumatic full thickness rotator cuff tears using a multicenter prospective cohort study design. Methods Patients with atraumatic full thickness rotator cuff tears who consented to enroll provided data via questionnaire on demographics, symptom characteristics, co-morbidities, willingness to undergo surgery, and patient related outcome assessments (SF-12, ASES, WORC, SANE score, Shoulder Activity Scale). Physicians recorded physical examination and imaging data. Patients began a physical therapy program developed from a systematic review of the literature and returned for evaluation at 6 and 12 weeks. At those visits patients could chose one of three courses: 1.) Cured (no formal follow up scheduled), 2.) Improved (continue therapy with scheduled reassessment in 6 weeks), or 3.) No better (offered surgery). Patients were contacted by telephone at 1 and 2 years to determine if they had undergone surgery since their last visit. A Wilcoxon signed rank test with continuity correction was used to compare initial, 6 week, and 12 week outcome scores. Results The cohort consists of 452 patients. Patient reported outcomes improved significantly at 6 and 12 weeks. Patients elected to undergo surgery less than 25% of the time. Patients who decided to have surgery generally did so between 6 and 12 weeks, and few had surgery between 3 and 24 months. Conclusion Non-operative treatment using this physical therapy protocol is effective for treating atraumatic full thickness rotator cuff tears in approximately 75% of patients followed for two years. Level of evidence Level IV, Case Series, Treatment Study PMID:23540577

  7. An X-ray monitor for measurement of a titanium tritide target thickness

    NASA Technical Reports Server (NTRS)

    Alger, D. L.; Steinberg, R.

    1972-01-01

    An X-ray device capable of measuring titanium tritide film thickness from 0.1 to 30 micrometers has been built and tested. The monitor was designed for use in a rotating target system which used thick targets and incorporated a sputtering electrode to remove depleted layers from the target surface. The thickness measurement can be done in the presence of an intense background of bremsstrahlung and characteristic titanium X-radiation. A measurement can be accomplished in situ in two hours with reasonable accuracy.

  8. Accurate Measurement of Small Airways on Low-Dose Thoracic CT Scans in Smokers

    PubMed Central

    Conradi, Susan H.; Atkinson, Jeffrey J.; Zheng, Jie; Schechtman, Kenneth B.; Senior, Robert M.; Gierada, David S.

    2013-01-01

    Background: Partial volume averaging and tilt relative to the scan plane on transverse images limit the accuracy of airway wall thickness measurements on CT scan, confounding assessment of the relationship between airway remodeling and clinical status in COPD. The purpose of this study was to assess the effect of partial volume averaging and tilt corrections on airway wall thickness measurement accuracy and on relationships between airway wall thickening and clinical status in COPD. Methods: Airway wall thickness measurements in 80 heavy smokers were obtained on transverse images from low-dose CT scan using the open-source program Airway Inspector. Measurements were corrected for partial volume averaging and tilt effects using an attenuation- and geometry-based algorithm and compared with functional status. Results: The algorithm reduced wall thickness measurements of smaller airways to a greater degree than larger airways, increasing the overall range. When restricted to analyses of airways with an inner diameter < 3.0 mm, for a theoretical airway of 2.0 mm inner diameter, the wall thickness decreased from 1.07 ± 0.07 to 0.29 ± 0.10 mm, and the square root of the wall area decreased from 3.34 ± 0.15 to 1.58 ± 0.29 mm, comparable to histologic measurement studies. Corrected measurements had higher correlation with FEV1, differed more between BMI, airflow obstruction, dyspnea, and exercise capacity (BODE) index scores, and explained a greater proportion of FEV1 variability in multivariate models. Conclusions: Correcting for partial volume averaging improves accuracy of airway wall thickness estimation, allowing direct measurement of the small airways to better define their role in COPD. PMID:23172175

  9. Thickening of the inferior glenohumeral capsule: an ultrasound sign for shoulder capsular contracture.

    PubMed

    Michelin, Paul; Delarue, Yohann; Duparc, Fabrice; Dacher, Jean Nicolas

    2013-10-01

    The aim of this retrospective study was to measure the inferior glenohumeral capsule thickness of shoulders clinically affected by capsular contracture by comparison to the contralateral asymptomatic side. Bilateral shoulder ultrasound (US) examinations of 20 patients with clinically or MRI proven unilateral capsular contracture were retrospectively assessed. Inferior capsule evaluation was performed with a transducer placed within the axilla in maximally abducted shoulders. Measurements were symmetrically performed orthogonally to the inferior glenohumeral ligament (IGHL) in the axial plane; the coronal plane was used to ensure the tension of the IGHL. The significance of any difference in thickening was assessed with the Mann-Whitney test. The average thickness was 4.0 mm in shoulders with capsular contracture vs. 1.3 mm in asymptomatic contralateral shoulders (P < 0.0001). Twenty per cent of patients with capsular contracture and inferior capsule thickness increase showed US features of other painful diseases of the rotator cuff. The thickness of the inferior capsule is measurable through ultrasound examination and appears to be increased in shoulders with capsular contracture. Exploration of the inferior aspect of the shoulder joint could be added to shoulder US examination protocols for capsular contracture assessment even if other rotator cuff abnormalities are diagnosed by US. • Ultrasound is increasingly used to diagnose shoulder problems. • The thickness of the inferior glenohumeral ligament is measurable in the axilla. • The inferior glenohumeral ligament appears thickened in shoulders with capsular contracture. • Capsular contracture ultrasound features can be associated with other rotator cuff problems.

  10. Rotary seal with enhanced lubrication and contaminant flushing

    DOEpatents

    Dietle, Lannie L.

    2000-01-01

    A resilient, ring shaped interference-type hydrodynamic rotary seal having waves on the lubricant side which provide increased film thickness and flushing action by creating contact pressure induced angulated restrictions formed by abrupt restrictive diverters. The angulated restrictions are defined by projecting ridges, corners at the trailing edge of the waves, or simply by use of a converging shape at the trailing edge of the waves which is more abrupt than the gently converging hydrodynamic inlet shape at the leading edge of the waves. The abrupt restrictive diverter performs two functions; a restricting function and a diverting function. The angulated restrictions cause a local film thickness restriction which produces a damming effect preventing a portion of the lubricant from leaking out of the dynamic sealing interface at the trailing edge of the wave, and results in a much thicker lubricant film thickness under the waves. This contributes to more film thickness in the remainder of the dynamic sealing interface toward the environment because film thickness tends to decay gradually rather than abruptly due to the relative stiffness of the seal material. Because of the angle of the abrupt restrictive diverter relative to the relative rotation direction, in conjunction with the restriction or damming effect, a strong diverting action is produced which pumps lubricant across the dynamic sealing interface toward the environment. The lubricant diversion is caused by the component of the rotational velocity tangent to the abrupt restrictive diverter. The component of rotational velocity normal to the abrupt restrictive diverter causes a portion of the lubricant film to be pumped past the abrupt restrictive diverter, thereby assuring adequate lubrication thereof.

  11. Accounting for partiality in serial crystallography using ray-tracing principles.

    PubMed

    Kroon-Batenburg, Loes M J; Schreurs, Antoine M M; Ravelli, Raimond B G; Gros, Piet

    2015-09-01

    Serial crystallography generates `still' diffraction data sets that are composed of single diffraction images obtained from a large number of crystals arbitrarily oriented in the X-ray beam. Estimation of the reflection partialities, which accounts for the expected observed fractions of diffraction intensities, has so far been problematic. In this paper, a method is derived for modelling the partialities by making use of the ray-tracing diffraction-integration method EVAL. The method estimates partialities based on crystal mosaicity, beam divergence, wavelength dispersion, crystal size and the interference function, accounting for crystallite size. It is shown that modelling of each reflection by a distribution of interference-function weighted rays yields a `still' Lorentz factor. Still data are compared with a conventional rotation data set collected from a single lysozyme crystal. Overall, the presented still integration method improves the data quality markedly. The R factor of the still data compared with the rotation data decreases from 26% using a Monte Carlo approach to 12% after applying the Lorentz correction, to 5.3% when estimating partialities by EVAL and finally to 4.7% after post-refinement. The merging R(int) factor of the still data improves from 105 to 56% but remains high. This suggests that the accuracy of the model parameters could be further improved. However, with a multiplicity of around 40 and an R(int) of ∼50% the merged still data approximate the quality of the rotation data. The presented integration method suitably accounts for the partiality of the observed intensities in still diffraction data, which is a critical step to improve data quality in serial crystallography.

  12. Solute boundary layer on a rotating crystal

    NASA Astrophysics Data System (ADS)

    Povinelli, Michelle L.; Korpela, Seppo A.; Chait, Arnon

    1994-11-01

    A perturbation analysis has been carried out for the solutal boundary layer next to a rotating crystal. Our aim is to extend the classical results of Burton, Prim and Slicher [1] in order to obtain higher order terms in asymptotic expansions for the concentration field and boundary-layer thickness. Expressions for the effective segregation coefficient are directly obtained from the concentration solution in the two limits that correspond to weak and strong rotation.

  13. Restorative Effects of Uridine Plus Docosahexaenoic Acid in a Rat Model of Parkinson’s Disease

    PubMed Central

    Cansev, Mehmet; Ulus, Ismail H.; Wang, Lei; Maher, Timothy J.; Wurtman, Richard J.

    2008-01-01

    Summary Administering uridine-5’-monophosphate (UMP) and docosahexaenoic acid (DHA) increases synaptic membranes (as characterized by pre-and post-synaptic proteins) and dendritic spines in rodents. We examined their effects on rotational behavior and dopaminergic markers in rats with partial unilateral 6-hydroxydopamine (6-OHDA)-induced striatal lesions. Rats receiving UMP, DHA, both, or neither, daily, and intrastriatal 6-OHDA 3 days after treatment onset, were tested for d-amphetamine-induced rotational behavior and dopaminergic markers after 24 and 28 days, respectively. UMP/DHA treatment reduced ipsilateral rotations by 57% and significantly elevated striatal dopamine, tyrosine hydroxylase (TH) activity, TH protein and Synapsin-1 on the lesioned side. Hence, giving uridine and DHA may partially restore dopaminergic neurotransmission in this model of Parkinson’s Disease. PMID:18761383

  14. Restorative effects of uridine plus docosahexaenoic acid in a rat model of Parkinson's disease.

    PubMed

    Cansev, Mehmet; Ulus, Ismail H; Wang, Lei; Maher, Timothy J; Wurtman, Richard J

    2008-11-01

    Administering uridine-5'-monophosphate (UMP) and docosahexaenoic acid (DHA) increases synaptic membranes (as characterized by pre- and post-synaptic proteins) and dendritic spines in rodents. We examined their effects on rotational behavior and dopaminergic markers in rats with partial unilateral 6-hydroxydopamine (6-OHDA)-induced striatal lesions. Rats receiving UMP, DHA, both, or neither, daily, and intrastriatal 6-OHDA 3 days after treatment onset, were tested for d-amphetamine-induced rotational behavior and dopaminergic markers after 24 and 28 days, respectively. UMP/DHA treatment reduced ipsilateral rotations by 57% and significantly elevated striatal dopamine, tyrosine hydroxylase (TH) activity, TH protein and synapsin-1 on the lesioned side. Hence, giving uridine and DHA may partially restore dopaminergic neurotransmission in this model of Parkinson's disease.

  15. Hybrid theory and calculation of e-N2 scattering. [quantum mechanics - nuclei (nuclear physics)

    NASA Technical Reports Server (NTRS)

    Chandra, N.; Temkin, A.

    1975-01-01

    A theory of electron-molecule scattering was developed which was a synthesis of close coupling and adiabatic-nuclei theories. The theory is shown to be a close coupling theory with respect to vibrational degrees of freedom but is a adiabatic-nuclei theory with respect to rotation. It can be applied to any number of partial waves required, and the remaining ones can be calculated purely in one or the other approximation. A theoretical criterion based on fixed-nuclei calculations and not on experiment can be given as to which partial waves and energy domains require the various approximations. The theory allows all cross sections (i.e., pure rotational, vibrational, simultaneous vibration-rotation, differential and total) to be calculated. Explicit formulae for all the cross sections are presented.

  16. The Microwave Spectrum of Partially Deuterated Species of Dimethyl Ether

    NASA Astrophysics Data System (ADS)

    Lauvergnat, D.; Margulès, L.; Motiyenko, R. A.; Guillemin, J.-C.; Coudert, L. H.

    2011-06-01

    Dimethyl ether is a molecule of astrophysical interest spectroscopically well characterized. It is one of the simplest molecules with two methyl groups undergoing large amplitude internal rotations. Due to deuterium enrichment in the interstellar medium, one can reasonably expect that partially deuterated species of dimethyl ether might be detected. However, there are no spectroscopic results about the microwave spectrum of such species. A theoretical calculation of the rotation-torsion energy levels of the partially deuterated species of dimethyl ether has been undertaken aided by ab initio calculations. The approach accounts for the complicated torsion-rotation interactions displayed by this molecule and for the fact that deuteration leads to changes of the bidimensional internal rotation effective potential energy surface. Due to zero-point energy contributions from the 19 small amplitude vibrational modes, this surface no longer displays G36 symmetry. Rotation-torsion energy levels are computed treating the two angles of internal rotation as active coordinates and evaluating Hamiltonian matrix elements with the help of Gaussian quadrature. It is hoped that the present results will allow us to understand the microwave spectrum of the mono deuterated species CH_2DOCH_3 which has been recorded in Lille with the new sub millimeter wave spectrometer (150--950 GHz) based on harmonic generation of solid-state sources. [2] Snyder, Buhl, and Schwartz, Astrophys. J. Letters 191 (1974) L79. [3] Endres, Drouin, Pearson, Müller, Lewen, Schlemmer, and Giesen, A&A 504 (2009) 635. [4] Solomon and Woolf, Astrophys. J. Letters 180 (1973) L89. [5] Lauvergnat and Nauts, J. Chem. Phys. 116 (2002) 8560; and Light and Bačić, J. Chem. Phys. 87 (1987) 4008.

  17. Does Additional Biceps Augmentation Improve Rotator Cuff Healing and Clinical Outcomes in Anterior L-Shaped Rotator Cuff Tears? Clinical Comparisons With Arthroscopic Partial Repair.

    PubMed

    Jeon, Yoon Sang; Lee, Juyeob; Kim, Rag Gyu; Ko, Young-Won; Shin, Sang-Jin

    2017-11-01

    The repair of anterior L-shaped tears is usually difficult because of the lack of anterior rotator cuff tendon to cover the footprint. The biceps tendon is usually exposed from the retracted anterolateral corner of the torn tendon and can be easily used to augment rotator cuff repair. Hypothesis/Purpose: This study compared the clinical outcomes of the biceps augmentation technique with those of partial tendon repair for the arthroscopic treatment of large anterior L-shaped rotator cuff tears to evaluate the role of additional biceps augmentation in tendon healing. We hypothesized that the biceps augmentation technique would lead to a lower rotator cuff tendon retear rate and provide satisfactory functional outcomes. Cohort study; Level of evidence, 3. This study included 64 patients with anterior L-shaped rotator cuff tears who underwent arthroscopic repair. Patients were divided into 2 groups: group A (31 patients) underwent repair of an anterior L-shaped tear combined with biceps augmentation, and group B (33 patients) had a partially repaired tendon whose footprint was exposed after repair without undue tension on the retracted tendon. Clinical evaluations were performed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, muscle strength, visual analog scale for pain, and patient satisfaction. Magnetic resonance imaging (MRI) was performed for tendon integrity at 6 months postoperatively. The mean period of follow-up was 29.1 ± 3.5 months (range, 24-40 months). The mean ASES and Constant scores significantly improved from 52.8 ± 10.6 and 43.2 ± 9.9 preoperatively to 88.2 ± 6.9 and 86.8 ± 6.2 at final follow-up in group A ( P < .001) and from 53.0 ± 11.8 and 44.3 ± 11.3 preoperatively to 87.4 ± 7.2 and 87.9 ± 7.3 at final follow-up in group B ( P < .001). Overall muscle strength (given as % of the other side's strength) significantly increased from preoperatively to final follow-up in group A (forward flexion [FF]: 62.0 ± 8.2 to 89.0 ± 8.6; external rotation [ER]: 57.5 ± 9.9 to 86.8 ± 9.3; internal rotation [IR]: 68.1 ± 10.8 to 88.1 ± 8.4; P < .001) and group B (FF: 59.9 ± 9.6 to 87.7 ± 9.0; ER: 58.6 ± 9.3 to 86.2 ± 7.5; IR: 70.0 ± 9.3 to 87.0 ± 8.4; P < .001). Twenty-one patients (67.7%) in group A and 20 patients (60.6%) in group B showed a healed rotator cuff tendon on postoperative MRI. The retear rate between the 2 groups showed no significant difference ( P = .552). Regarding clinical outcomes, both groups had no significant difference in the ASES score ( P = .901), Constant score ( P = .742), and muscle strength. There was no significant difference in the clinical outcomes and retear rate of anterior L-shaped tears between biceps augmentation and partial tendon repair. Additional biceps augmentation proved to have no enhancement in tendon healing. A precise method such as only partial tendon repair for reducing the footprint exposure without undue tension may be considered as one of the treatment options for large anterior L-shaped rotator cuff tears.

  18. Impact of Platelet-Rich Plasma on Arthroscopic Repair of Small- to Medium-Sized Rotator Cuff Tears

    PubMed Central

    Holtby, Richard; Christakis, Monique; Maman, Eran; MacDermid, Joy C.; Dwyer, Tim; Athwal, George S.; Faber, Kenneth; Theodoropoulos, John; Woodhouse, Linda J.; Razmjou, Helen

    2016-01-01

    Background: Increased interest in using platelet-rich plasma (PRP) as an augment to rotator cuff repair warrants further investigation, particularly in smaller rotator cuff tears. Purpose: To examine the effectiveness of PRP application in improving perioperative pain and function and promoting healing at 6 months after arthroscopic repair of small- or medium-sized rotator cuff tears. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: This was a double-blinded randomized controlled trial of patients undergoing arthroscopic repair of partial- or full-thickness rotator cuff tears of up to 3 cm who were observed for 6 months. Patients were randomized to either repair and PRP application (study group) or repair only (control group) groups. The patient-oriented outcome measures utilized were the visual analog scale (VAS), the Short Western Ontario Rotator Cuff Index (ShortWORC), the American Shoulder and Elbow Surgeons (ASES) form, and the Constant-Murley Score (CMS). Range of motion (ROM) and inflammatory and coagulation markers were measured before and after surgery. Magnetic resonance imaging was used at 6 months to assess retear and fatty infiltration rate. Results: Eighty-two patients (41 males) with a mean age of 59 ± 8 years were enrolled; 41 patients were included in each group. Both the PRP and control groups showed a significant improvement in their pain level based on the VAS within the first 30 days (P < .0001), with the PRP group reporting less pain than the control group (P = .012), which was clinically significantly different from days 8 through 11. The PRP group reported taking less painkillers (P = .026) than the control group within the first 30 days. All outcome measure scores and ROM improved significantly after surgery (P < .0001), with no between-group differences. No differences were observed between groups in inflammatory or coagulation marker test results (P > .05), retear (14% vs 18% full retear; P = .44), or fatty infiltration rate (P = .08). Conclusion: The PRP biological augmentation for repair of small- to medium-sized rotator cuff tears has a short-term effect on perioperative pain without any significant impact on patient-oriented outcome measures or structural integrity of the repair compared with control group. PMID:27660800

  19. Partial melting of amphibolite to trondhjemite at Nunatak Fiord, St. Elias Mountains, Alaska

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barker, F.; McLellan, E.L.; Plafker, G.

    1985-01-01

    At Nunatak Fiord, 55km NE of Yakutat, Alaska, a uniform layer of Cretaceous basalt ca. 3km thick was metamorphosed ca. 67 million years ago to amphibolite and locally partially melted to pegmatitic trondhjemite. Segregations of plagioclase-quartz+/-biotite rock, leucosomes in amphibolite matrix, range from stringers 5-10mm thick to blunt pods as thick as 6m. They tend to be parallel to foliation of the amphibolite, but crosscutting is common. The assemblage aluminous hornblende-plagioclase-epidote-sphene-quartz gave a hydrous melt that crystallized to plagioclase-quartz+/-biotite pegmatitic trondhjemite. 5-10% of the rock melted. Eu at 2x chondrites is positively anomalous. REE partitioning in melt/residum was controlled largelymore » by hornblende and sphene. Though the mineralogical variability precludes quantitative modeling, partial melting of garnet-free amphibolite to heavy-REE-depleted trondhjemitic melt is a viable process.« less

  20. Swivel Joint For Liquid Nitrogen

    NASA Technical Reports Server (NTRS)

    Milner, James F.

    1988-01-01

    Swivel joint allows liquid-nitrogen pipe to rotate through angle of 100 degree with respect to mating pipe. Functions without cracking hard foam insulation on lines. Pipe joint rotates on disks so mechanical stress not transmitted to thick insulation on pipes. Inner disks ride on fixed outer disks. Disks help to seal pressurized liquid nitrogen flowing through joint.

  1. Anodic concentration loss and impedance characteristics in rotating disk electrode microbial fuel cells.

    PubMed

    Shen, Liye; Ma, Jingxing; Song, Pengfei; Lu, Zhihao; Yin, Yao; Liu, Yongdi; Cai, Lankun; Zhang, Lehua

    2016-10-01

    A rotating disk electrode (RDE) was used to investigate the concentration loss and impedance characteristics of anodic biofilms in microbial fuel cells (MFCs). Amperometric time-current analysis revealed that at the rotation rate of 480 rpm, a maximum current density of 168 µA cm(-2) can be achieved, which was 22.2 % higher than when there was no rotation. Linear sweep voltammetry and electrochemical impedance spectroscopy tests showed that when the anodic potential was set to -300 mV vs. Ag/AgCl reference, the power densities could increase by 59.0  %, reaching 1385 mW m(-2), the anodic resistance could reduce by 19  %, and the anodic capacitance could increase by 36 %. These results concur with a more than 85 % decrease of the diffusion layer thickness. Data indicated that concentration loss, diffusion layer thickness, and the mixing velocity play important roles in anodic resistance reduction and power output of MFCs. These findings could be helpful to the design of future industrial-scale MFCs with mixed bacteria biofilms.

  2. Synchronization of coupled active rotators by common noise

    NASA Astrophysics Data System (ADS)

    Dolmatova, Anastasiya V.; Goldobin, Denis S.; Pikovsky, Arkady

    2017-12-01

    We study the effect of common noise on coupled active rotators. While such a noise always facilitates synchrony, coupling may be attractive (synchronizing) or repulsive (desynchronizing). We develop an analytical approach based on a transformation to approximate angle-action variables and averaging over fast rotations. For identical rotators, we describe a transition from full to partial synchrony at a critical value of repulsive coupling. For nonidentical rotators, the most nontrivial effect occurs at moderate repulsive coupling, where a juxtaposition of phase locking with frequency repulsion (anti-entrainment) is observed. We show that the frequency repulsion obeys a nontrivial power law.

  3. Restoration of shoulder biomechanics according to degree of repair completion in a cadaveric model of massive rotator cuff tear: importance of margin convergence and posterior cuff fixation.

    PubMed

    Oh, Joo Han; McGarry, Michelle H; Jun, Bong Jae; Gupta, Akash; Chung, Kyung Chil; Hwang, James; Lee, Thay Q

    2012-11-01

    Complete repair in massive rotator cuff tear may not be possible, allowing for only partial repair. However, the effect of partial repair on glenohumeral biomechanics has not been evaluated. Therefore, the purpose of this study was to compare the rotational range of motion (ROM), glenohumeral kinematics, and gap formation at the repaired tendon edge following massive cuff tear and repair according to the degree of repair completion. Posterior fixation will restore the altered biomechanics of massive rotator cuff tear. Controlled laboratory study. Eight cadaveric shoulders were tested at 0°, 30°, and 60° of abduction in the scapular plane. Muscle loading was applied based on physiological muscle cross-sectional area ratios. Maximum internal (MaxIR) and external rotations (MaxER) were measured. Humeral head apex (HHA) position and gap formation at the repaired tendon edge were measured using a MicroScribe from MaxIR to MaxER in 30° increments. Testing was performed for intact, massive cuff tear, complete repair, and 4 types of partial repair. A repeated-measures analysis of variance was used to determine significant differences. Massive tear significantly increased ROM and shifted HHA superiorly in MaxIR at all abduction angles (P < .05). The complete repair restored ROM to intact (P < .05), while all partial repairs did not. Abnormal HHA elevation due to massive tear was restored by all repairs (P < .05). Release of the anterior single row alone and release of the marginal convergence significantly increased gap formation at the anterior tendon edge (P < .05). This study emphasizes the importance of anterior fixation in massive cuff tear to restore rotational range of motion and decrease gap formation at the repaired tendon edge and of posterior fixation to restore abnormal glenohumeral kinematics due to massive cuff tear. If complete repair of massive cuff tear is not possible, posterior cuff (infraspinatus) repair is necessary to restore abnormal glenohumeral kinematics, and margin convergence anteriorly is recommended to decrease gap formation of the repaired tendon edge, which may provide a better biomechanical environment for healing.

  4. Partial slip effect in the flow of MHD micropolar nanofluid flow due to a rotating disk - A numerical approach

    NASA Astrophysics Data System (ADS)

    Ramzan, Muhammad; Chung, Jae Dong; Ullah, Naeem

    The aim of present exploration is to study the flow of micropolar nanofluid due to a rotating disk in the presence of magnetic field and partial slip condition. The governing coupled partial differential equations are reduced to nonlinear ordinary differential equations using appropriate transformations. The differential equations are solved numerically by using Maple dsolve command with option numeric which utilize Runge-Kutta fourth-fifth order Fehlberg technique. A comparison to previous study is also added to validate the present results. Moreover, behavior of different parameters on velocity, microrotation, temperature and concentration of nanofluid are presented via graphs and tables. It is noted that the slip effect and magnetic field decay the velocity and microrotation or spin component.

  5. Is the arthroscopic modified tension band suture technique suitable for all full-thickness rotator cuff tears?

    PubMed

    Bae, Kyu Hwan; Kim, Jeong Woo; Kim, Tae Kyun; Kweon, Seok Hyun; Kang, Hong Je; Kim, Jong Yun; Joo, Min Su; Kim, Dong Moon

    2016-09-01

    We aimed to identify the clinical and structural outcomes after arthroscopic repair of full-thickness rotator cuff tears of all sizes with a modified tension band suture technique. Among 63 patients who underwent arthroscopic rotator cuff repair for a full-thickness rotator cuff tear with the modified tension band suture technique at a single hospital between July 2011 and March 2013, 47 were enrolled in this study. The mean follow-up period was 29 months. Visual analog scale scores, range of motion, American Shoulder and Elbow Surgeons scores, Constant scores, and Shoulder Strength Index were measured preoperatively and at the final follow-up. For radiologic evaluation, we conducted magnetic resonance imaging 6 months postoperatively and ultrasonography at the final follow-up. We allocated the small and medium tears to group A and the large and massive tears to group B and then compared clinical outcomes and repair integrity. Postoperative clinical outcomes at the final follow-up showed significant improvements compared with those seen during preoperative evaluations (P < .001). However, group B showed worse clinical results than group A. Evaluation with magnetic resonance imaging performed 6 months postoperatively and ultrasonography taken at the final follow-up revealed that group B showed a significantly higher retear rate than did group A (69% vs. 6%, respectively; P < .001). Arthroscopic repair with the modified tension band suture technique for rotator cuff tears was a more suitable method for small to medium tears than for large to massive tears. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Clinical outcomes and repair integrity after arthroscopic full-thickness rotator cuff repair: suture-bridge versus double-row modified Mason-Allen technique.

    PubMed

    Lee, Kwang Won; Yang, Dae Suk; Lee, Gyu Sang; Ma, Chang Hyun; Choy, Won Sik

    2018-05-23

    This retrospective study compared the clinical and radiologic outcomes of patients who underwent arthroscopic rotator cuff repairs by the suture-bridge and double-row modified Mason-Allen techniques. From January 2012 to May 2013, 76 consecutive cases of full-thickness rotator cuff tear, 1 to 4 cm in the sagittal plane, for which arthroscopic rotator cuff repair was performed, were included. The suture-bridge technique was used in 37 consecutive shoulders; and the double-row modified Mason-Allen technique, in 39 consecutive shoulders. Clinical outcomes at a minimum of 2 years (mean, 35.7 months) were evaluated postoperatively using the visual analog scale; University of California, Los Angeles Shoulder Scale; American Shoulder and Elbow Surgeons Subjective Shoulder Scale; and Constant score. Postoperative cuff integrity was evaluated at a mean of 17.7 months by magnetic resonance imaging. At the final follow-up, the clinical outcomes improved in both groups (all P < .001) but with no significant differences between the 2 groups (all P > .05). The retear rate was 18.9% in the shoulders subjected to suture-bridge repair and 12.8% in the double-row modified Mason-Allen group; the difference was not significant (P = .361). Despite the presence of fewer suture anchors, the patients who underwent double-row modified Mason-Allen repair had comparable shoulder functional outcomes and a comparable retear rate with those who underwent suture-bridge repair. Therefore, the double-row modified Mason-Allen repair technique can be considered an effective treatment for patients with medium- to large-sized full-thickness rotator cuff tears. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Transport Phenomena in Thin Rotating Liquid Films Including: Nucleate Boiling

    NASA Technical Reports Server (NTRS)

    Faghri, Amir

    2005-01-01

    In this grant, experimental, numerical and analytical studies of heat transfer in a thin liquid film flowing over a rotating disk have been conducted. Heat transfer coefficients were measured experimentally in a rotating disk heat transfer apparatus where the disk was heated from below with electrical resistance heaters. The heat transfer measurements were supplemented by experimental characterization of the liquid film thickness using a novel laser based technique. The heat transfer measurements show that the disk rotation plays an important role on enhancement of heat transfer primarily through the thinning of the liquid film. Experiments covered both momentum and rotation dominated regimes of the flow and heat transfer in this apparatus. Heat transfer measurements have been extended to include evaporation and nucleate boiling and these experiments are continuing in our laboratory. Empirical correlations have also been developed to provide useful information for design of compact high efficiency heat transfer devices. The experimental work has been supplemented by numerical and analytical analyses of the same problem. Both numerical and analytical results have been found to agree reasonably well with the experimental results on liquid film thickness and heat transfer Coefficients/Nusselt numbers. The numerical simulations include the free surface liquid film flow and heat transfer under disk rotation including the conjugate effects. The analytical analysis utilizes an integral boundary layer approach from which

  8. Conformational statistics of stiff macromolecules as solutions to partial differential equations on the rotation and motion groups

    PubMed

    Chirikjian; Wang

    2000-07-01

    Partial differential equations (PDE's) for the probability density function (PDF) of the position and orientation of the distal end of a stiff macromolecule relative to its proximal end are derived and solved. The Kratky-Porod wormlike chain, the Yamakawa helical wormlike chain, and the original and revised Marko-Siggia models are examples of stiffness models to which the present formulation is applied. The solution technique uses harmonic analysis on the rotation and motion groups to convert PDE's governing the PDF's of interest into linear algebraic equations which have mathematically elegant solutions.

  9. Full-Thickness Reconstruction with Pedicle Flap and Diced Homologous Cartilage Over the Pericardium Complicated. Cardiac Arrest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rees, Thomas D.

    1961-01-01

    Successful repair by plastic surgery of nonhealing ulceration of the chest wall, induced by radiotherapy for breast cancer, is described. Reconstruction of the chest wali defect by pedicle flap coverage was carried out. Radiation injury extended through the entire thickness of the chest wall and osteoradionecrosis of the ribs was present. Reconstruction with thoracoabdominal tube was considered to be the best technique, so a 4- by 9-in. tube pedicle was constructed. The underlying donor wound of the pedicle was covered with a split- thickness skin graft. Healing was without incident, and approximates 3 weeks after formation, the inferior end ofmore » this tube pedicle was migrated to the left epigastrium as an intermediate step. Healing was uncomplicated, and the lateral attachment of the pedicle was partially severed. Three weeks later, resection of all avascular tissue along with portions of the fourth and fifth ribs was carried out. This created a full-thickness chest wall defect measuring 4 by 8 in., with the anterior surface of the pericardial sac exposed in the wound. The end of the abdominal tube pedicle was elevated from its bed, rotated into position, and sutured to the healthy margins of the chest wall defect. The exposed subcutaneous fat of the undersurface of the pedicle was placed in juxtaposition to the pericardium. A split-thickness skin graft was cut from the skin of the left thigh and draped over the pedicle flap donor wound. All sutured wounds healed per primum and the entire skin graft survived. The inferior inset of the tube pedicle was cut free and the pedicle flap was tailored into position 6 weeks later. The patient was discharged from the hospital in good condition and engaged in normal activities. An attempt was made to provide protection for the heart beneath the pedicle inset by introduction of diced homologous cartilage grafts, just beneath the skin of the pedicle flap. This healed with the formation of a thick fibrocartilaginous structure providing some protection for the pericardial contents beneath.« less

  10. Influence of glenoid component design and humeral component retroversion on internal and external rotation in reverse shoulder arthroplasty: a cadaver study.

    PubMed

    Berhouet, J; Garaud, P; Favard, L

    2013-12-01

    A common disadvantage of reverse shoulder arthroplasty is limitation of the range of arm rotation. Several changes to the prosthesis design and implantation technique have been suggested to improve rotation range of motion (ROM). Glenoid component design and degree of humeral component retroversion influence rotation ROM after reverse shoulder arthroplasty. The Aequalis Reversed™ shoulder prosthesis (Tornier Inc., Edina, MN, USA) was implanted into 40 cadaver shoulders. Eight glenoid component combinations were tested, five with the 36-mm sphere (centred seating, eccentric seating, inferior tilt, centred with a 5-mm thick lateralised spacer, and centred with a 7-mm thick lateralised spacer) and three with the 42-mm sphere (centred with no spacer or with a 7-mm or 10-mm spacer). Humeral component position was evaluated with 0°, 10°, 20°, 30°, and 40° of retroversion. External and internal rotation ROMs to posterior and anterior impingement on the scapular neck were measured with the arm in 20° of abduction. The large glenosphere (42 mm) was associated with significantly (P<0.05) greater rotation ROMs, particularly when combined with a lateralised spacer (46° internal and 66° external rotation). Rotation ROMs were smallest with the 36-mm sphere. Greater humeral component retroversion was associated with a decrease in internal rotation and a significant increase (P<0.05) in external rotation. The best balance between rotation ROMs was obtained with the native retroversion, which was estimated at 17.5° on average in this study. Our anatomic study in a large number of cadavers involved a detailed and reproducible experimental protocol. However, we did not evaluate the variability in scapular anatomy. Earlier studies of the influence of technical parameters did not take humeral component retroversion into account. In addition, no previous studies assessed rotation ROMs. Rotation ROM should be improved by the use of a large-diameter glenosphere with a spacer to lateralise the centre of rotation of the gleno-humeral joint, as well as by positioning the humeral component at the patient's native retroversion value. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  11. Rotational superradiant scattering in a vortex flow

    NASA Astrophysics Data System (ADS)

    Torres, Theo; Patrick, Sam; Coutant, Antonin; Richartz, Maurício; Tedford, Edmund W.; Weinfurtner, Silke

    2017-09-01

    When an incident wave scatters off of an obstacle, it is partially reflected and partially transmitted. In theory, if the obstacle is rotating, waves can be amplified in the process, extracting energy from the scatterer. Here we describe in detail the first laboratory detection of this phenomenon, known as superradiance. We observed that waves propagating on the surface of water can be amplified after being scattered by a draining vortex. The maximum amplification measured was 14% +/- 8%, obtained for 3.70 Hz waves, in a 6.25-cm-deep fluid, consistent with the superradiant scattering caused by rapid rotation. We expect our experimental findings to be relevant to black-hole physics, since shallow water waves scattering on a draining fluid constitute an analogue of a black hole, as well as to hydrodynamics, due to the close relation to over-reflection instabilities.

  12. Accounting for partiality in serial crystallography using ray-tracing principles

    PubMed Central

    Kroon-Batenburg, Loes M. J.; Schreurs, Antoine M. M.; Ravelli, Raimond B. G.; Gros, Piet

    2015-01-01

    Serial crystallography generates ‘still’ diffraction data sets that are composed of single diffraction images obtained from a large number of crystals arbitrarily oriented in the X-ray beam. Estimation of the reflection partialities, which accounts for the expected observed fractions of diffraction intensities, has so far been problematic. In this paper, a method is derived for modelling the partialities by making use of the ray-tracing diffraction-integration method EVAL. The method estimates partialities based on crystal mosaicity, beam divergence, wavelength dispersion, crystal size and the interference function, accounting for crystallite size. It is shown that modelling of each reflection by a distribution of interference-function weighted rays yields a ‘still’ Lorentz factor. Still data are compared with a conventional rotation data set collected from a single lysozyme crystal. Overall, the presented still integration method improves the data quality markedly. The R factor of the still data compared with the rotation data decreases from 26% using a Monte Carlo approach to 12% after applying the Lorentz correction, to 5.3% when estimating partialities by EVAL and finally to 4.7% after post-refinement. The merging R int factor of the still data improves from 105 to 56% but remains high. This suggests that the accuracy of the model parameters could be further improved. However, with a multiplicity of around 40 and an R int of ∼50% the merged still data approximate the quality of the rotation data. The presented integration method suitably accounts for the partiality of the observed intensities in still diffraction data, which is a critical step to improve data quality in serial crystallography. PMID:26327370

  13. Should massive rotator cuff tears be reconstructed even when only partially repairable?

    PubMed

    Godenèche, Arnaud; Freychet, Benjamin; Lanzetti, Riccardo Maria; Clechet, Julien; Carrillon, Yannick; Saffarini, Mo

    2017-07-01

    (1) To evaluate midterm functional outcomes of arthroscopic repair of massive rotator cuff tears and (2) to determine the prognostic factors that could influence outcome. The hypothesis was that both partial and complete repairs would result in equivalent improvement of clinical score. From a prospective series of 525 rotator cuff repairs, we analysed records of the 73 patients who were treated for massive tears. The median follow-up was 41 months (range 29-55), and functional outcome was evaluated using the Constant score, shoulder strength, and subjective shoulder value. The median CS improved from 34 points to 81 points (p < 0.001). The scores were better for both types of two-tendon tears, posterosuperior (83, n = 33) and anterosuperior (85, n = 13) (n.s.), than for three-tendon tears (74, n = 27) (p < 0.001). The scores were also better when fatty infiltration was of stage I (84, n = 28) than of stage II (78, n = 34) (p < 0.001) or stage III (74, n = 11) (p = 0.04). The scores were only slightly higher for completely reparable tears (81.5, n = 50) than for partially reparable tears (79, n = 23) (n.s.). Ultrasonic examination revealed incomplete healing, in 10 of the 50 completely repaired tears, and in 11 of the 23 partially repaired tears. The results of the present study compare favourably with those in recent literature and confirm the hypothesis that both partial and complete repairs of massive rotator cuff tears produce equivalent improvements of Constant scores. The clinical relevance of these observations is that even if repairs of two-tendon tears result in superior functional outcomes, repairs of three-tendon tears produce equivalent 'relative' improvement that grants sufficient patient satisfaction and autonomy. Comparative case series, Level IV.

  14. Clinical applications of perforator-based propeller flaps in upper limb soft tissue reconstruction.

    PubMed

    Ono, Shimpei; Sebastin, Sandeep J; Yazaki, Naoya; Hyakusoku, Hiko; Chung, Kevin C

    2011-05-01

    A propeller flap is an island flap that moves from one orientation to another by rotating around its vascular axis. The vascular axis is stationary, and flap movement is achieved by revolving on this axis. Early propeller flaps relied on a thick, subcutaneous pedicle to maintain vascularity, and this limited the flap rotation to 90°. With increasing awareness of the location and the vascular territory perfused by cutaneous perforators, it is now possible to design propeller flaps based on a single perforator, so-called "perforator-based propeller flaps." These flaps permit flap rotation up to 180°. We present the results of upper limb soft tissue reconstruction using perforator-based propeller flaps. We constructed a treatment strategy based on the location of the soft tissue defect and the perforator anatomy for expedient wound coverage in 1 stage. All perforator-based propeller flaps derived from 3 institutions that were used for upper limb soft tissue reconstruction were retrospectively analyzed. The parameters studied included the size and location of the defect, the perforator that was used, the size and shape of the flap, the direction (ie, clockwise or counter-clockwise) of flap rotation, the degree of twisting of the perforator, the management of the donor site (ie, linear closure or skin grafting), and flap survival (recorded as the percentage of the flap area that survived). Twelve perforator-based propeller flaps were used to reconstruct upper limb soft tissue defects in 12 patients. Six different perforators were used as vascular pedicles. The donor defects of 11 flaps could be closed primarily. One flap was partially lost in a patient with electrical burns. Perforator-based propeller flaps provide a reliable option for covering small- to medium-size upper limb soft tissue defects. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Paleomagnetism and Lithostratigraphy of the Miocene Tuff of Huntoon Creek Type Section

    NASA Astrophysics Data System (ADS)

    Johnson, S.; Pluhar, C. J.; Lindeman, J. R.

    2014-12-01

    Here we define the Tuff of Huntoon Creek (THC), previously identified and mapped in Mono Basin, CA by Gilbert et al. (1968) as "latite ignimbrite" (K-Ar date of 11.1-11.9 Ma). Formally defining this formation and its paleomagnetic characteristics, can help reveal the spatial and temporal relationships of the Walker Lane and Mina Deflection structural features, including distribution of vertical axis rotation. THC is composed of four tuffs with an intercalated volcaniclastic sandstone giving a total stratigraphic thickness of ~300 m. We define THC in a gorge of Huntoon Creek, where the stratigraphic section is capped by Pliocene basalt. The lowest and most extensive stratigraphic unit, the Huntoon Valley member of THC, is ~243 m thick and can be distinguished from other units by the presence of sanidine and biotite phenocrysts and normal polarity. A 7-meter-thick volcaniclastic sandstone overlies the Huntoon Valley member, straddling a magnetic polarity reversal within the section. The 3 overlying members of THC are reversed-polarity, biotite-bearing, sanidine-free tuffs of variable degrees of welding. Their paleomagnetic directions are each statistically distinguishable from the others, indicating that the deposition of each tuff is separated by a significant amount of time and can be used as a geologically instantaneous measure of Earth's magnetic field for purposes of averaging out secular variation. The capping Pliocene olivine basalt was emplaced over an erosional unconformity of significant relief, as evidenced by the complete absence at some locations of the uppermost biotite-bearing THC member. The tilt corrected mean paleomagnetic direction for the 4 members of THC indicate a clockwise rotation magnitude of 77.5°±40.3°. The absolute rotation results of this locality are statistically indistinguishable from the relative rotation results of this locality compared to Cowtrack Mountain (Lindeman et al. 2013). The corroboration of these data suggests that this region of the Mina Deflection has undergone large magnitude clockwise rotation since the emplacement of THC. However, the capping basalt exhibits a magnetic declination of due north, suggesting that this unit experienced little rotation and that rotational deformation in this region had mostly ended by the time of its emplacement at ~3.5 Ma.

  16. High-Resolution 3-T Magnetic Resonance Imaging of the Shoulder in Nonsymptomatic Professional Baseball Pitcher Draft Picks.

    PubMed

    Del Grande, Filippo; Aro, Michael; Jalali Farahani, Sahar; Cosgarea, Andrew; Wilckens, John; Carrino, John A

    2016-01-01

    To retrospectively assess the qualitative and quantitative high-resolution 3-T magnetic resonance imaging (MRI) findings in nonsymptomatic baseball pitcher draft picks. Institutional review board-approved and HIPAA compliant study. Three-Tesla MRI of the dominant shoulder of 19 asymptomatic baseball pitcher draft picks and detailed clinical examination was performed before contract signing. Two radiologists performed independently qualitative and quantitative evaluation of shoulder structures. Descriptive statistics were performed. Sixty-eight percent (13/19), 32% (6/19), and 21% (4/19) of the baseball pitcher draft picks showed tendinopathy, partial thickness tendon tear of the supraspinatus, and acromioclavicular joint osteoarthritis, respectively. Glenohumeral subluxation, glenoid remodeling, and Bennett lesion were present in 53% (10/19), 79% (15/19), and 21% (4/19) of the subjects, respectively. Interclass coefficient was 0.633 to 0.863 and κ was 0.27 to 1. In asymptomatic baseball pitcher draft picks, 3-T MRI frequently shows abnormalities involving rotator cuff tendons, the coracohumeral, inferior glenohumeral, labrum, and osseous structures.

  17. High-resolution imaging gamma-ray spectroscopy with externally segmented germanium detectors

    NASA Technical Reports Server (NTRS)

    Callas, J. L.; Mahoney, W. A.; Varnell, L. S.; Wheaton, W. A.

    1993-01-01

    Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. An angular resolution of 0.2 deg becomes practical by combining position-sensitive germanium detectors having a segment thickness of a few millimeters with a one-dimensional coded aperture located about a meter from the detectors. Correspondingly higher angular resolutions are possible with larger separations between the detectors and the coded aperture. Two-dimensional images can be obtained by rotating the instrument. Although the basic concept is similar to optical or X-ray coded-aperture imaging techniques, several complicating effects arise because of the penetrating nature of gamma rays. The complications include partial transmission through the coded aperture elements, Compton scattering in the germanium detectors, and high background count rates. Extensive electron-photon Monte Carlo modeling of a realistic detector/coded-aperture/collimator system has been performed. Results show that these complicating effects can be characterized and accounted for with no significant loss in instrument sensitivity.

  18. Centrifuge in Free Fall: Combustion at Partial Gravity

    NASA Technical Reports Server (NTRS)

    Ferkul, Paul

    2017-01-01

    A centrifuge apparatus is developed to study the effect of variable acceleration levels in a drop tower environment. It consists of a large rotating chamber, within which the experiment is conducted. NASA Glenn Research Center 5.18-second Zero-Gravity Facility drop tests were successfully conducted at rotation rates up to 1 RPS with no measurable effect on the overall Zero-Gravity drop bus. Arbitrary simulated gravity levels from zero to 1-g (at a radius of rotation 30 cm) were produced. A simple combustion experiment was used to exercise the capabilities of the centrifuge. A total of 23 drops burning a simulated candle with heptane and ethanol fuel were performed. The effect of gravity level (rotation rate) and Coriolis force on the flames was observed. Flames became longer, narrower, and brighter as gravity increased. The Coriolis force tended to tilt the flames to one side, as expected, especially as the rotation rate was increased. The Zero-Gravity Centrifuge can be a useful tool for other researchers interested in the effects of arbitrary partial gravity on experiments, especially as NASA embarks on future missions which may be conducted in non-Earth gravity.

  19. Ultrasound measures of supraspinatus tendon thickness and acromiohumeral distance in rotator cuff tendinopathy are reliable.

    PubMed

    McCreesh, Karen M; Anjum, Shakeel; Crotty, James M; Lewis, Jeremy S

    2016-01-01

    Rotator cuff (RC) tendinopathy has been widely ascribed to impingement of the supraspinatus tendon (SsT) in the subacromial space, measured as the acromiohumeral distance (AHD). Ultrasound (US) is suitable for measuring AHD and SsT thickness, but few reliability studies have been carried out in symptomatic populations, and interrater reliability is unconfirmed. This study aimed to examine the intrarater and interrater reliability of US measurements of AHD and SsT thickness in asymptomatic control subjects and patients with RC tendinopathy. Seventy participants were recruited and grouped as healthy controls (n = 25) and RC tendinopathy (n = 45). Repeated US measurements of AHD and SsT thickness were obtained by one rater in both groups and by two raters in the RC tendinopathy group. Intrarater and interrater reliability coefficients were excellent for both measurements (intraclass correlation > 0.92), but the intrarater reliability was superior. The minimal detectable change values in the symptomatic group were 0.7 mm for AHD and 0.6 mm for SsT thickness for a single experienced examiner; the values rose to 1.2 mm and 1.3 mm, respectively, for the pair of examiners. The results support the reliability of US for the measurement of AHD and SsT thickness in patients with symptomatic RC tendinopathy and provide minimal detectable change values for use in future research studies. © 2015 Wiley Periodicals, Inc.

  20. Arthroscopic versus mini-open rotator cuff repair: a prospective, randomized study with 24-month follow-up.

    PubMed

    Zhang, Zhenxiang; Gu, Beibei; Zhu, Wei; Zhu, Lixian; Li, Qingsong

    2014-08-01

    This prospective, randomized study was performed to evaluate the results of mini-open and arthroscopic rotator cuff repair in a comparative case series of patients followed for 24 months. A total of 125 patients were randomized to mini-open (Group I) or arthroscopic (Group II) rotator cuff repair at the time of surgical intervention. The University of California Los Angeles (UCLA) score, the American Shoulder and Elbow Surgeons (ASES) index, and muscle strength were measured to evaluate the clinical results, while magnetic resonance arthrography was used at 24-month follow-up to investigate the postoperative rotator cuff integrity. Fifty-three patients in Group I and 55 patients in Group II were available for evaluation at 24-month follow-up. At 24-month follow-up, the UCLA score, the ASES index, and muscle strength were statistically significantly increased in both groups postoperatively, while no significant difference was detected between the 2 groups. Intact rotator cuffs were investigated in 42 patients in Group I and 35 in Group II, and there was a significant difference in postoperative structural integrity between the two groups (P < 0.05). When analysis was limited to the patients with full-thickness tear, the muscle strength of the shoulder was significantly better in Group II, and the retearing rate was significantly higher in Group II. Based on the results obtained from this study, it can be indicated that arthroscopic and mini-open rotator cuff repair displayed substantially equal outcomes, except for higher retearing rate in the arthroscopic repair group. While for patients with full-thickness tear, arthroscopic rotator cuff repair displayed better shoulder strength and significantly higher retearing rate as compared to mini-open rotator cuff repair at 24-month follow-up.

  1. Poster - 11: Radiation barrier thickness calculations for the GammaPod

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    La Russa, Daniel; Vandervoort, Eric; Wilkins, Davi

    A consortium of radiotherapy centers in North America is in the process of evaluating a novel new {sup 60}Co teletherapy device, called the GammaPod™ (Xcision Medical Systems, Columbia Maryland), designed specifically for breast SBRT. The GammaPod consists of 36 collimated {sup 60}Co sources with a total activity of 4320 Ci. The sources are housed in a hemispherical source carrier that rotates during treatment to produce a cylindrically symmetric cone of primary beam spanning 16° – 54° degrees from the horizontal. This unique beam geometry presents challenges when designing or evaluating room shielding for the purposes of meeting regulatory requirements, andmore » for ensuring the safety of staff and the public in surrounding areas. Conventional methods for calculating radiation barrier thicknesses have been adapted so that barrier transmission factors for the GammaPod can be determined from a few relevant distances and characteristics of the primary beam. Simple formalisms have been determined for estimating shielding requirements for primary radiation (with a rotating and non-rotating source carrier), patient-scattered radiation, and leakage radiation. When making worst case assumptions, it was found that conventional barrier thicknesses associated with linac treatment suites are sufficient for shielding all sources of radiation from the GammaPod.« less

  2. Effect of trailing edge thickness on the performance of a helium turboexpander used in cryogenic refrigeration and liquefaction cycles

    NASA Astrophysics Data System (ADS)

    Sam, Ashish Alex; Ghosh, Parthasarathi

    2017-02-01

    Turboexpanders in cryogenic refrigeration and liquefaction cycles, which is of radial inflow configuration, constitute stationary and rotating components like nozzle, a rotating wheel and a diffuser. The relative motion between the stationary and rotating components and the interactions of secondary flows and vortices at different stages make the turboexpander flow unsteady. Computational Fluid Dynamics (CFD) analysis of this flow is essential to identify the scope for improvement in efficiency. The trailing edge vortex formed due to the mixing of the pressure and suction side streams is an important phenomenon to analyse, as this leads to efficiency degradation of the machine. Additionally, there are mechanical vibrations and dynamic loading associated with. This flow non-uniformity at the exit should be suppressed as this may affect the pressure recovery process in the diffuser and thereby the turboexpander’s performance. The strength of this vortex depends upon the geometrical parameters like trailing edge shape, thickness etc. In this paper, transient CFD analyses of a cryogenic turboexpander designed for helium refrigeration and liquefaction cycles using Ansys CFX® were performed to investigate the effect of trailing edge thickness on the turboexpander performance and the performance characteristics and the flow patterns were compared to understand the flow characteristics in each case.

  3. A flowing partially penetrating well in a finite-thickness aquifer: a mixed-type initial boundary value problem

    NASA Astrophysics Data System (ADS)

    Chang, Chien-Chieh; Chen, Chia-Shyun

    2003-02-01

    An analytical approach using integral transform techniques is developed to deal with a well hydraulics model involving a mixed boundary of a flowing partially penetrating well, where constant drawdown is stipulated along the well screen and no-flux condition along the remaining unscreened part. The aquifer is confined of finite thickness. First, the mixed boundary is changed into a homogeneous Neumann boundary by discretizing the well screen into a finite number of segments, each of which at constant drawdown is subject to unknown a priori well bore flux. Then, the Laplace and the finite Fourier transforms are used to solve this modified model. Finally, the prescribed constant drawdown condition is reinstated to uniquely determine the well bore flux function, and to restore the relation between the solution and the original model. The transient and the steady-state solutions for infinite aquifer thickness can be derived from the semi-analytical solution, complementing the currently available dual integral solution. If the distance from the edge of the well screen to the bottom/top of the aquifer is 100 times greater than the well screen length, aquifer thickness can be assumed infinite for times of practical significance, and groundwater flow can reach a steady-state condition, where the well will continuously supply water under a constant discharge. However, if aquifer thickness is smaller, the well discharge decreases with time. The partial penetration effect is most pronounced in the vicinity of the flowing well, decreases with increasing horizontal distance, and vanishes at distances larger than 1-2 times the aquifer thickness divided by the square root of aquifer anisotropy. The horizontal hydraulic conductivity and the specific storage coefficient can be determined from vertically averaged drawdown as measured by fully penetrating observation wells. The vertical hydraulic conductivity can be determined from the well discharge under two particular partial penetration conditions.

  4. Proton Density Fat-Fraction of Rotator Cuff Muscles Is Associated With Isometric Strength 10 Years After Rotator Cuff Repair: A Quantitative Magnetic Resonance Imaging Study of the Shoulder.

    PubMed

    Karampinos, Dimitrios C; Holwein, Christian; Buchmann, Stefan; Baum, Thomas; Ruschke, Stefan; Gersing, Alexandra S; Sutter, Reto; Imhoff, Andreas B; Rummeny, Ernst J; Jungmann, Pia M

    2017-07-01

    Quantitative muscle fat-fraction magnetic resonance (MR) imaging techniques correlate with semiquantitative Goutallier scores with failure after rotator cuff (RC) repair. To investigate the relationship of proton density fat fraction (PDFF) of the RC muscles with semiquantitative MR scores, cartilage T2 relaxation times, and clinical isometric strength measurements in patients 10 years after unilateral RC repair. Cross-sectional study; Level of evidence, 3. Bilateral shoulder MR imaging was performed in 13 patients (11 male, 2 female; age, 72 ± 8 years) 10.9 ± 0.4 years after unilateral autologous periosteal flap augmented RC repair (total shoulders assessed, N = 26). Goutallier classification, muscle atrophy, RC tendon integrity, and cartilage defects were determined based on morphological MR sequences. A paracoronal 2D multi-slice multi-echo sequence was used for quantitative cartilage T2 mapping. A chemical shift-encoding-based water-fat separation technique (based on a 6-echo 3D spoiled gradient echo sequence) was used for quantification of the PDFF of RC muscles. Isometric shoulder abduction strength was measured clinically. Mean and SD, Pearson correlation, and partial Spearman correlation were calculated. There were 6 RC full-thickness retears in ipsilateral shoulders and 6 RC full-thickness tears in contralateral shoulders. Isometric shoulder abduction strength was not significantly different between ipsilateral and contralateral shoulders (50 ± 24 N vs 54 ± 24 N; P = .159). The mean PDFF of RC muscles was 11.7% ± 10.4% (ipsilateral, 14.2% ± 8.5%; contralateral, 9.2% ± 7.8%; P = .002). High supraspinatus PDFF correlated significantly with higher Goutallier scores ( R = 0.75, P < .001) and with lower isometric muscle strength ( R = -0.49, P = .011). This correlation remained significant after adjustment for muscle area measurements and tendon rupture ( R = -0.41, P = .048). More severe cartilage defects at the humerus were significantly associated with higher supraspinatus PDFF ( R = 0.44; P = .023). Cartilage T2 values did not correlate with muscle PDFF ( P > .05). MR imaging-derived RC muscle PDFF is associated with isometric strength independent of muscle atrophy and tendon rupture in shoulders with early and advanced degenerative changes. It therefore provides complementary, clinically relevant information in tracking RC muscle composition on a quantitative level.

  5. Tape casting and partial melting of Bi-2212 thick films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density ofmore » 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).« less

  6. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  7. Organization of model helical peptides in lipid bilayers: insight into the behavior of single-span protein transmembrane domains.

    PubMed Central

    Sharpe, Simon; Barber, Kathryn R; Grant, Chris W M; Goodyear, David; Morrow, Michael R

    2002-01-01

    Selectively deuterated transmembrane peptides comprising alternating leucine-alanine subunits were examined in fluid bilayer membranes by solid-state nuclear magnetic resonance (NMR) spectroscopy in an effort to gain insight into the behavior of membrane proteins. Two groups of peptides were studied: 21-mers having a 17-amino-acid hydrophobic domain calculated to be close in length to the hydrophobic thickness of 1-palmitoyl-2-oleoyl phosphatidylcholine and 26-mers having a 22-amino-acid hydrophobic domain calculated to exceed the membrane hydrophobic thickness. (2)H NMR spectral features similar to ones observed for transmembrane peptides from single-span receptors of higher animal cells were identified which apparently correspond to effectively monomeric peptide. Spectral observations suggested significant distortion of the transmembrane alpha-helix, and/or potential for restriction of rotation about the tilted helix long axis for even simple peptides. Quadrupole splittings arising from the 26-mer were consistent with greater peptide "tilt" than were those of the analogous 21-mer. Quadrupole splittings associated with monomeric peptide were relatively insensitive to concentration and temperature over the range studied, indicating stable average conformations, and a well-ordered rotation axis. At high peptide concentration (6 mol% relative to phospholipid) it appeared that the peptide predicted to be longer than the membrane thickness had a particular tendency toward reversible peptide-peptide interactions occurring on a timescale comparable with or faster than approximately 10(-5) s. This interaction may be direct or lipid-mediated and was manifest as line broadening. Peptide rotational diffusion rates within the membrane, calculated from quadrupolar relaxation times, T(2e), were consistent with such interactions. In the case of the peptide predicted to be equal to the membrane thickness, at low peptide concentration spectral lineshape indicated the additional presence of a population of peptide having rotational motion that was restricted on a timescale of 10(-5) s. PMID:12080125

  8. A similarity measure for partially folded proteins: application to unfolded and native-like conformational fluctuations

    NASA Astrophysics Data System (ADS)

    Larios, Edgar; Yang, Wei Y.; Schulten, K.; Gruebele, M.

    2004-12-01

    Computing the root-mean-square deviation (RMSD) of a partially folded protein structure from the folded state requires the two structures to be translationally and rotationally aligned. We examine the constraint matrix L that preserves orthogonality of the rotation matrix during minimization of the RMSD. L is proportional to the sensitivity of the RMSD to the rotational alignment matrix. Its trace yields an isotropic reaction coordinate, while its off-diagonal matrix elements are related to the moment of inertia derivative tensor that encodes anisotropic information about the structure. We use L to compare λ-repressor fragment 6-85 (λ 6-85) to several partially folded structures obtained from molecular dynamics simulation (MD), and find that L as a reaction coordinate indeed encodes some information about protein topology. We also apply C α RMSD, L and tryptophan sidechain mobility as criteria for native state structural fluctuations of several λ 6-85 mutants. The mutants' denaturation curves and fluorescence quenching are measured experimentally for comparison. The results are in accord with a recent proposal that structural fluctuations near the chromophore can induce increased native state fluorescence or hyperfluorescence during unfolding of proteins.

  9. Maximizing the short circuit current of organic solar cells by partial decoupling of electrical and optical properties

    NASA Astrophysics Data System (ADS)

    Qarony, Wayesh; Hossain, Mohammad I.; Jovanov, Vladislav; Knipp, Dietmar; Tsang, Yuen Hong

    2018-03-01

    The partial decoupling of electronic and optical properties of organic solar cells allows for realizing solar cells with increased short circuit current and energy conversion efficiency. The proposed device consists of an organic solar cell conformally prepared on the surface of an array of single and double textured pyramids. The device geometry allows for increasing the optical thickness of the organic solar cell, while the electrical thickness is equal to the nominal thickness of the solar cell. By increasing the optical thickness of the solar cell, the short circuit current is distinctly increased. The quantum efficiency and short circuit current are determined using finite-difference time-domain simulations of the 3D solar cell structure. The influence of different solar cell designs on the quantum efficiency and short circuit current is discussed and optimal device dimensions are proposed.

  10. Negative pressure wound therapy for partial-thickness burns.

    PubMed

    Dumville, Jo C; Munson, Christopher

    2012-12-12

    A burn wound is a complex and evolving injury, with both local and systemic consequences. Burn treatments include a variety of dressings, as well as newer strategies, such as negative pressure wound therapy (NPWT), which, by means of a suction force that drains excess fluids from the burn, tries to promote the wound healing process and minimise progression of the burn wound. To assess the effectiveness of NPWT for people with partial-thickness burns. For this third update we searched the Cochrane Wounds Group Specialised Register (searched 18 May 2012); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 5); Ovid MEDLINE (2010 to May Week 2 2012); Ovid MEDLINE (In-Process & Other Non-Indexed Citations 17 May 2012); Ovid EMBASE (2010 to 2012 Week 19); and EBSCO CINAHL (2010 to 16 May 2012). All randomised controlled trials (RCTs) and controlled clinical trials (CCTs) that evaluated the safety and effectiveness of NPWT for partial-thickness burns. Two review authors used standardised forms, and extracted the data independently. We assessed each trial for risk of bias, and resolved differences by discussion. One RCT, that was an interim report, satisfied the inclusion criteria. We undertook a narrative synthesis of results, as the absence of data and poor reporting precluded us from carrying out any formal statistical analysis. The trial was at high risk of bias. There was not enough evidence available to permit any conclusions to be drawn regarding the use of NPWT for treatment of partial-thickness burn wounds.

  11. Systemic and Microvascular Effects of Resuscitation with Blood Products After Severe Hemorrhage in Rats

    DTIC Science & Technology

    2014-01-01

    thickness, blood flow, and microvascular permeability were studied using intravital microscopy. Hemodynamics and coagulation tests (rotational...Microcirculation; packed red blood cells; intravital microscopy; ROTEM; plasma proteins; rats. Current US military guidance for the resuscitation of warfighters...was used for coagulation assays (rotational thromboelast- ometry [ROTEM], TEM Innovations GmbH, Germany). Intravital Microscopy and Animal Preparation

  12. Masks For Deposition Of Aspherical Optical Surfaces

    NASA Technical Reports Server (NTRS)

    Rogers, John R.; Martin, John D.

    1992-01-01

    Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.

  13. INTEGRITY OF THE SUBSCAPULARIS TENDON AFTER OPEN SURGERY FOR THE TREATMENT OF ANTERIOR SHOULDER INSTABILITY: A CLINICAL AND RADIOLOGICAL EVALUATION.

    PubMed

    Lech, Osvandré; Piluski, Paulo; Tambani, Renato; Castro, Nero; Pimentel, Gilnei

    2009-01-01

    To evaluate the integrity of the subscapularis tendon by strength, function and magnetic resonance imaging after deltopectoralis access for anterior shoulder instability. 20 patients with anterior shoulder instability have been evaluated. Minimum follow-up was 12 months, with a mean of 40 months. Only male patients were included, with a mean of age of 29 years (20 - 42 years). The patients have been submitted to physical examinations of mobility, muscular strength, Belly Test and Gerber Test. The isokinetic strength in internal and external rotation, in angular speeds of 60(0)/s and 180(0)/s, for both shoulders was measured using a dynamometer. In 15 patients magnetic resonance imaging (MRI) was carried out on both shoulders for evaluating the thickness, cross-sectional area and atrophy of the subscapularis muscle. A significant difference was found between torque peaks at the speed of 60(0)/s for internal (p=0.036) and external (p=0.008) rotation. However, at 180(0)/s the opposite happens (internal rotation: p=0.133; external rotation: p=0.393). Subscapularis muscle thickness and area are significantly smaller than the normal side, with a deficit of 19% and 23%, respectively. According to Rowe and UCLA scores, we find excellent and good results for the majority of patients, with a mean of 88 and 31.6 points, respectively. Despite of the good functional results, open surgery can limit strength and reduce the thickness and the cross-sectional area of subscapularis muscle. However, the best results were found in the patients who had the dominant side operated.

  14. Comparative physical and chemical analyses of cotton fibers from two near isogenic upland lines differing in fiber wall thickness

    USDA-ARS?s Scientific Manuscript database

    The thickness of cotton fiber cell walls is an important property that partially determines the economic value of cotton. To better understand the physical and chemical manifestations of the genetic variations that regulate the degree of fiber wall thickness, we used a comprehensive set of methods t...

  15. Analysis of continuous beams with joint slip

    Treesearch

    L. A. Soltis

    1981-01-01

    A computer analysis with user guidelines to analyze partially continuous multi-span beams is presented. Partial continuity is due to rotational slip which occurs at spliced joints at the supports of continuous beams such as floor joists. Beam properties, loads, and joint slip are input; internal forces, reactions, and deflections are output.

  16. Analysis of microstructure and mechanical properties of aluminium-copper joints welded by FSW process

    NASA Astrophysics Data System (ADS)

    Iordache, M.; Sicoe, G.; Iacomi, D.; Niţu, E.; Ducu, C.

    2017-08-01

    The research conducted in this article aimed to check the quality of joining some dissimilar materials Al-Cu by determining the mechanical properties and microstructure analysis. For the experimental measurements there were used tin alloy Al - EN-AW-1050A with a thickness of 2 mm and Cu99 sheet with a thickness of 2 mm, joined by FSW weld overlay. The main welding parameters were: rotating speed of the rotating element 1400 rev/min, speed of the rotating element 50 mm/min. The experimental results were determined on samples specially prepared for metallographic analysis. In order to prepare samples for their characterization, there was designed and built a device that allowed simultaneous positioning and fixing for grinding. The characteristics analyzed in the joint welded samples were mictrostructure, microhardness and residual stresses. The techniques used to determine these characteristics were optical microscopy, electron microscopy with fluorescence radioactive elemental analysis (EDS), Vickers microhardness line - HV0.3 and X-ray diffractometry.

  17. Human Health Countermeasures - Partial-Gravity Analogs Workshop

    NASA Technical Reports Server (NTRS)

    Barr, Yael; Clement, Gilles; Norsk, Peter

    2016-01-01

    The experimental conditions that were deemed the most interesting by the HHC Element lead scientists are those permitting studies of the long-term effects of exposure to (a) chronic rotation when supine or in head down tilt (ground-based); and (b) long-radius centrifugation (space based). It is interesting to note that chronic ground based slow rotation room studies have not been performed since the 1960's, when the USA and USSR were investigating the potential use of AG for long-duration space missions. On the other hand, the other partial gravity analogs, i.e., parabolic flight, HUT, suspension, and short-radius centrifugation, have been regularly used in the last three decades (see review in Clément et al. 2015). Based on the workshop evaluations and the scores by the HHC scientific disciplines indicated in tables 3 and 4, simulation of partial G between 0 and 1 should be prioritized as follows: Priority 1. Chronic space-based partial-G analogs: a. Chronic space-based long-radius centrifugation. The ideal scenario would be chronic long-radius centrifugation of cells, animals and humans in a translational research approach - ideally beyond low earth orbit under deep space environmental effects and at various rotations - to obtain different G-effects. In this scenario, all physiological systems could be evaluated and the relationship between physiological response and G level established. This would be the most integrative way of defining, for the first time ever, G-thresholds for each physiological system. b. Chronic space-based centrifugation of animals. Chronic centrifugation of rodents at various G levels in space would allow for determination of AG thresholds of protection for each physiological system. In this case, all physiological systems will be of interest. Intermittent centrifugation will be of secondary interest. c. Chronic space-based centrifugation of cell cultures (RWV). Bioreactor studies of cells and cell cultures of various tissues at various G levels would allow for intracellular investigations of the effects of partial-G. Priority 2. Acute, intermittent space based partial-G analogs: a. Acute, intermittent space-based short radius human centrifugation. Intermittent centrifugation of humans would allow determination of thresholds of AG for protection of astronaut health in space. Priority 3. Chronic ground-based partial-G analogs: a. Chronic centrifugation of supine or head-down tilted humans. b. Chronic head-up tilt in humans. c. Chronic head-out graded dry immersion in humans. d. Chronic partial suspension of rodents e. Chronic rotating bioreactor cell culture studies (RWV) Priority 4. Acute ground based partial-G analogs. a. Parabolic flights. Very acute and short term effects of G levels between 0 and 1 in humans for fast responding systems like cardiovascular and sensorimotor as well as for acute responses in cell cultures and animals. b. Other acute models as indicated in table 3.

  18. Turbine and method for reducing shock losses in a turbine

    DOEpatents

    Ristau, Neil

    2015-09-01

    A turbine includes a rotor and a casing that circumferentially surrounds at least a portion of the rotor. The rotor and the casing at least partially define a gas path through the turbine. A last stage of rotating blades is circumferentially arranged around the rotor and includes a downstream swept portion radially outward from the rotor. A method for reducing shock losses in a turbine includes removing a last stage of rotating blades circumferentially arranged around a rotor and replacing the last stage of rotating blades with rotating blades having a downstream swept portion radially outward from the rotor.

  19. A new Faraday rotator for high average power lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khazanov, E A

    2001-04-30

    The new design of a Faraday rotator is proposed which allows one to compensate partially the radiation depolarisation in magneto-optical elements induced by heating due to the laser radiation absorption. The new design is compared analytically and numerically with a conventional design for the cases of glass and crystal magneto-optical media. It is shown that a rotator, which provides the compensation for birefringence in active elements with the accuracy up to 1 % at the average laser radiation power of 1 kW in the rotator, can be created. (laser applications and other topics in quantum electronics)

  20. Observation of partial relaxation mechanisms via anisotropic strain relief on epitaxial islands using semiconductor nanomembranes

    NASA Astrophysics Data System (ADS)

    Rosa, Barbara L. T.; Marçal, Lucas A. B.; Ribeiro Andrade, Rodrigo; Dornellas Pinto, Luciana; Rodrigues, Wagner N.; Lustoza Souza, Patrícia; Pamplona Pires, Mauricio; Wagner Nunes, Ricardo; Malachias, Angelo

    2017-07-01

    In this work we attempt to directly observe anisotropic partial relaxation of epitaxial InAs islands using transmission electron microscopy (TEM) and synchrotron x-ray diffraction on a 15 nm thick InAs:GaAs nanomembrane. We show that under such conditions TEM provides improved real-space statistics, allowing the observation of partial relaxation processes that were not previously detected by other techniques or by usual TEM cross section images. Besides the fully coherent and fully relaxed islands that are known to exist above previously established critical thickness, we prove the existence of partially relaxed islands, where incomplete 60° half-loop misfit dislocations lead to a lattice relaxation along one of the <110> directions, keeping a strained lattice in the perpendicular direction. Although individual defects cannot be directly observed, their implications to the resulting island registry are identified and discussed within the frame of half-loops propagations.

  1. Observation of partial relaxation mechanisms via anisotropic strain relief on epitaxial islands using semiconductor nanomembranes.

    PubMed

    Rosa, Barbara L T; Marçal, Lucas A B; Andrade, Rodrigo Ribeiro; Pinto, Luciana Dornellas; Rodrigues, Wagner N; Souza, Patrícia Lustoza; Pires, Mauricio Pamplona; Nunes, Ricardo Wagner; Malachias, Angelo

    2017-07-28

    In this work we attempt to directly observe anisotropic partial relaxation of epitaxial InAs islands using transmission electron microscopy (TEM) and synchrotron x-ray diffraction on a 15 nm thick InAs:GaAs nanomembrane. We show that under such conditions TEM provides improved real-space statistics, allowing the observation of partial relaxation processes that were not previously detected by other techniques or by usual TEM cross section images. Besides the fully coherent and fully relaxed islands that are known to exist above previously established critical thickness, we prove the existence of partially relaxed islands, where incomplete 60° half-loop misfit dislocations lead to a lattice relaxation along one of the 〈110〉 directions, keeping a strained lattice in the perpendicular direction. Although individual defects cannot be directly observed, their implications to the resulting island registry are identified and discussed within the frame of half-loops propagations.

  2. Hexagonal pattern instabilities in rotating Rayleigh-Bénard convection of a non-Boussinesq fluid: experimental results.

    PubMed

    Guarino, Alessio; Vidal, Valerie

    2004-06-01

    Motivated by the Küppers-Lortz instability of roll patterns in the presence of rotation, we have investigated the effects of rotation on a hexagonal pattern in Rayleigh-Bénard convection. While several theoretical models have been developed, experimental data cannot be found in the literature. In order to check the validity of the predictions and to study the effects of rotation on the behavior of the system, we present experimental results for a non-Boussinesq Rayleigh-Bénard convection with rotation about the vertical axis. Rotation introduces an additional control parameter, namely the dimensionless rotation rate Omega= 2 pi f d(2)/nu, where f is the rotation rate (in Hz), d is the thickness of the cell, and nu is the kinematic viscosity. We observe that the cell rotation induces a slow rotation of the pattern in the opposite direction (approximately Omega x 10(-4) ) in the rotating frame. Moreover, it tends to destroy the convective pattern. No oscillation of the hexagonal pattern over the range of its existence (Omega< or =6) has been observed.

  3. Topical Modulation of the Burn Wound Inflammatory Response to Improve Short and Long Term Outcomes

    DTIC Science & Technology

    2017-10-01

    casualty, treatment, organ failure, systemic inflammatory response syndrome , thermal injury, wound model, intervention 3. ACCOMPLISHMENTS:   What...thickness burns have a blister response. Using human eye or H&E studies, we did not observe any blisters in the pig model. However, the OCT...the deeper the partial thickness burn, the bigger the blister, until it gets close to full-thickness burns. The full-thickness burns are dry and

  4. Thermal and unroofing history of a thick, tilted Basin-and-Range crustal section in the Tortilla Mountains, Arizona

    USGS Publications Warehouse

    Howard, K.A.; Foster, D.A.

    1996-01-01

    We estimate here a geothermal gradient of only 17 ?? 5??C km-1 for the tilted Grayback fault block in southeastern Arizona when extension began ???25 Ma. This gradient is lower than preextension gradients estimated elsewhere in the Basin and Range, is only about 50% of typical gradients in the Basin and Range today, and needs to be accounted for in models of continental extension. The Grayback block exposes a 12-km-thick crustal section of Proterozoic and Cretaceous granitoids, which was tilted 90?? during extension between 25 and 15 Ma. Zircon fission-track ages decrease structurally downward (westward) across the block and were all within a zone of partial track annealing prior to tilting and quenching. The zircon age gradient suggests that the 220??-240??C isotherm migrated downward 5-6 km during Paleogene erosion and regional cooling. Apatite fission-track ages decrease westward from ???83 Ma in the structurally highest crystalline rocks to ???24 Ma at ???6-km paleodepth and then to ???15 Ma another 6 km farther west. Track-length analysis confirms that apatites above the break in slope in age at ???5.7-km paleodepth resided in a zone of partial annealing prior to tilting, and deeper apatites record rapid cooling upon tilting and unroofing beginning ???25 Ma. At that time the 110 ?? 10??C isotherm determined by the depth at which tracks in apatite were fully erased was at a basement paleodepth of ???5.7 km, and the 220 ?? 30??C isotherm as estimated from zircon data resided at a pretilting basement depth of ???12.15 km. From consistent values of paleogeothermal gradient for two depth intervals we estimate the pretilt gradient was 17 ?? 5??C km-1. From 25 to 15 Ma the rotating Grayback block cooled rapidly as higher, westward moving blocks unroofed it tectonically at a rate of ???1 km m.y.-1.

  5. A thick-walled sphere rotating in a uniform magnetic field: The next step to de-spin a space object

    NASA Astrophysics Data System (ADS)

    Nurge, Mark A.; Youngquist, Robert C.; Caracciolo, Ryan A.; Peck, Mason; Leve, Frederick A.

    2017-08-01

    Modeling the interaction between a moving conductor and a static magnetic field is critical to understanding the operation of induction motors, eddy current braking, and the dynamics of satellites moving through Earth's magnetic field. Here, we develop the case of a thick-walled sphere rotating in a uniform magnetic field, which is the simplest, non-trivial, magneto-statics problem that leads to complete closed-form expressions for the resulting potentials, fields, and currents. This solution requires knowledge of all of Maxwell's time independent equations, scalar and vector potential equations, and the Lorentz force law. The paper presents four cases and their associated experimental results, making this topic appropriate for an advanced student lab project.

  6. The Use of Implants to Improve Removable Partial Denture Function.

    PubMed

    Pimentel, Marcele Jardim; Arréllaga, Juan Pablo; Bacchi, Ataís; Del Bel Cury, Altair A

    2014-12-01

    The oral rehabilitation with conventional removable partial dentures in Kennedy class I patients allows continuous bone resorption, dislodgment of the prosthesis during the mastication caused by the resilience of the mucosa, and rotation of the prosthesis. Thus, the associations of distal implants become an attractive modality of treatment for these patients. This case report presented an association of removable partial dentures, milled crowns and osseointegrated implants to rehabilitate a partial edentulous patient. A removable partial denture associated with implants and metal-ceramic milled crowns can offer excellent esthetics, and will improve function and biomechanics, at a reduced cost.

  7. Effect of baffle on slosh reaction forces in rotating liquid helium subjected to a lateral impulse in microgravity

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Long, Y. T.

    1995-01-01

    Sloshing dynamics within a partially filled rotating Dewar of superfluid He II are investigated in response to a lateral impulse. The study investigates several factors, including how the rotating bubble of superfluid He II reacts to the impulse in microgravity, how the amplitudes of slosh reaction forces act on the Dewar with various rotating speeds, how the frequencies of the sloshing modes excited differ in terms of differences in rotating speeds, and how the sloshing dynamics differ with and without a baffle. The numerical computation of sloshing dynamics is based on the noninertial frame spacecraft-bound coordinates. Results of the simulations are illustrated.

  8. A Dynamic Pathway for Stone-Wales Bond Rotation on Carbon Nanotubes through Diamond-Like Bonds

    NASA Technical Reports Server (NTRS)

    Wei, Chen-Yu; Srivastava, Deepak; Cho, Kyeong-Jae; Menon, Madhu

    2003-01-01

    A new lower energy barrier with a two-step pathway of Stone-Wales (SW) ,ond rotation on carbon nanotubes (CNTs) is found through molecular dynamics (MD) simulations of CNTs under tension. The first step involves going over to a stable sp3-like metastable configuration with half rotated and partially tilted C-C bond. The second step involves going over to the fully rotated C-C bond with the formation of a SW defect in the nanotube. The energy barrier for this two-step dynamic pathway is significantly lower than the previously known static barrier for in-plane rotation of the C-C bond on a tensile strained (> 4%) CNT.

  9. Keratin-based products for effective wound care management in superficial and partial thickness burns injuries.

    PubMed

    Loan, Fiona; Cassidy, Sharon; Marsh, Clive; Simcock, Jeremy

    2016-05-01

    This n=40 cohort study on superficial and partial thickness burns compares novel keratin-based products with the standard products used at our facility. The keratin products are found to facilitate healing with minimal scarring, be well tolerated with minimal pain and itch, be easy to use for the health professional and be cost effective for the health care provider. For these reasons they are being adopted into use at our facility. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  10. Rotator cuff tear and sarcopenia: are these related?

    PubMed

    Chung, Seok Won; Yoon, Jong Pil; Oh, Kyung-Soo; Kim, Hyung Sup; Kim, Young Gun; Lee, Hyun-Joo; Jeong, Won-Ju; Kim, Dong-Hyun; Lee, Jong Soo; Yoon, Jee Wook

    2016-09-01

    Sarcopenia is the loss of muscle mass and consequent loss of muscle function with aging. Its prevalence among the general population is 12% to 30% in those aged >60 years. We evaluated (1) the difference in the prevalence of sarcopenia between patients with rotator cuff tear and controls and (2) the sarcopenia severity according to the size of the rotator cuff tear. Group 1 included 48 consecutive patients with chronic symptomatic full-thickness rotator cuff tears (mean age, 60.1 ± 6.5 years; range, 46-76 years), and group 2 included 48 age- and sex-matched patients. The sarcopenic index was evaluated by using the grip strength of the asymptomatic contralateral side and the skeletal muscle mass. No significant differences were found in the baseline data and demographic factors between the groups. The sarcopenic index was significantly inferior in the rotator cuff tear group than in the age- and sex-matched control groups (P = .041, .007, and .05, respectively). Patients with large to massive tears had a significantly inferior sarcopenic index than those with small and medium tears. The results showed that sarcopenia was more severe in patients with a chronic symptomatic full-thickness rotator cuff tear than in the age- and sex-matched control population and was correlated with the size of the tear, with the numbers available. Despite the individual variance in the underlying medical condition and physical activities, this study suggests that clinicians should consider the sarcopenic condition of patients with a rotator cuff tear, especially in elderly patients with large to massive tears. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Genetic and familial predisposition to rotator cuff disease: a systematic review.

    PubMed

    Dabija, Dominique I; Gao, Chan; Edwards, Todd L; Kuhn, John E; Jain, Nitin B

    2017-06-01

    Rotator cuff disease is a common disorder leading to shoulder pain and loss of function. Its etiology in atraumatic cases is uncertain and is likely to extend beyond repetitive microtrauma or overuse. Our objective was to determine whether there is a genetic or familial predisposition to rotator cuff disease. A literature search of PubMed and Embase databases identified 251 citations. After review of the titles, abstracts, and full articles, 7 met our inclusion and exclusion criteria. Four studies assessed familial predisposition to rotator cuff disease. One of these demonstrated that siblings of an individual with a rotator cuff tear were more likely to develop a full-thickness tear and more likely to be symptomatic. A 5-year follow-up showed that the relative risks were increased for the siblings to have a full-thickness tear, for a tear to progress in size, and for being symptomatic. Another study demonstrated that a significantly higher number of individuals with tears had family members with a history of tears or surgery than those without tears did. The other 3 studies investigated whether a genetic predisposition to rotator cuff disease exists and found significant association of haplotypes in DEFB1, FGFR1, FGF3, ESRRB, and FGF10 and 2 single-nucleotide polymorphisms within SAP30BP and SASH1. Prior studies provide preliminary evidence for genetic and familial predisposition to rotator cuff disease. However, there is a lack of large genome-wide studies that can provide more definitive information and guide early detection of individuals at risk, prophylactic rehabilitation, and potential gene therapies and regenerative medicine interventions. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Genetic and Familial Predisposition to Rotator Cuff Disease: A Systematic Review

    PubMed Central

    Dabija, Dominique I.; Gao, Chan; Edwards, Todd L; Kuhn, John E.; Jain, Nitin B.

    2017-01-01

    Background Rotator cuff disease is a common disorder leading to shoulder pain and loss of function. Its etiology in atraumatic cases is uncertain and likely extends beyond repetitive micro-trauma or overuse. Our objective was to determine whether there is a genetic or familial predisposition to rotator cuff disease. Methods A literature search of PubMed and EMBASE databases identified 251 citations. After reviewing the titles, abstracts, and full articles, seven met our inclusion/exclusion criteria. Results Four studies assessed familial predisposition to rotator cuff disease. One of these demonstrated that siblings of an individual with a rotator cuff tear were more likely to develop a full-thickness tear and more likely to be symptomatic. A five-year follow-up showed that the relative risks were increased for the siblings to have a full-thickness tear, for a tear to progress in size, and for being symptomatic. Another study demonstrated that a significantly higher number of individuals with tears had family members with a history of tears or surgery than those without tears. The other three studies investigated whether a genetic predisposition to rotator cuff disease exists and found significant association of haplotypes in DEFB1, FGFR1, FGFR3, ESRRB, and FGF10, and two single nucleotide polymorphisms within SAP30BP and SASH1. Conclusion Prior studies provide preliminary evidence for genetic and familial predisposition to rotator cuff disease. However, there is a lack of large genome-wide studies that can provide more definitive information and guide early detection of individuals at risk, prophylactic rehabilitation, and potential gene therapies and regenerative medicine interventions. Level of Evidence Systematic Review PMID:28162885

  13. A prospective randomized controlled trial comparing occupational therapy with home-based exercises in conservative treatment of rotator cuff tears.

    PubMed

    Krischak, Gert; Gebhard, Florian; Reichel, Heiko; Friemert, Benedikt; Schneider, Florian; Fisser, Christoph; Kaluscha, Rainer; Kraus, Michael

    2013-09-01

    This pilot study evaluates the outcome after occupational therapy, compared to home-based exercises in the conservative treatment of patients with full thickness rotator cuff tears. Forty-three adult subjects (range, 18-75 years), who had a full thickness rupture of the rotator cuff which was verified by magnetic imaging tomography, with clinical signs of a chronic rotator cuff impingement, and who were available for follow-up, were randomized to occupational therapy or to independent home-based exercises using a booklet. After drop-out, 38 patients were available for full examination at follow-up. Before therapy and after 2 months of conservative treatment, pain intensity, the Constant-Murley score, isokinetic strength testing in abduction and external rotation, functional limitation, clinical shoulder tests and health-related quality of life (EQ-5D) were evaluated. Two-thirds of the patients improved in clinical shoulder tests, regardless of the therapy group. There were no significant differences between the groups with reference to pain, range of motion, maximum peak force (abduction, external rotation), the Constant-Murley score, and the EQ-5D index. The only significant difference observed was the improvement in the self-assessed health- related quality of life (EQ-5D VAS) favoring home-based exercises. Home-based exercise, on the basis of an illustrated booklet with exercises twice a day, supplies comparable results to formal occupational therapy in the conservative treatment of rotator cuff tears. The results of this pilot study suggest some potential advantages related to psychological benefits using home-based treatment. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  14. Arthroscopic repair of massive contracted rotator cuff tears: aggressive release with anterior and posterior interval slides do not improve cuff healing and integrity.

    PubMed

    Kim, Sung-Jae; Kim, Sung-Hwan; Lee, Su-Keon; Seo, Jae-Wan; Chun, Yong-Min

    2013-08-21

    Few studies of large-to-massive contracted rotator cuff tears have examined the arthroscopic complete repair obtained by a posterior interval slide and whether the clinical outcomes or structural integrity achieved are better than those after partial repair without the posterior interval slide. The study included forty-one patients with large-to-massive contracted rotator cuff tears, not amenable to complete repair with margin convergence alone. The patients underwent either arthroscopic complete repair with a posterior interval slide and side-to-side repair of the interval slide edge (twenty-two patients; Group P) or partial repair with margin convergence (nineteen patients; Group M). The patient assignment was not randomized. The Simple Shoulder Test (SST), American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) shoulder score, and range of motion were used to compare the functional outcomes. Preoperative and six-month postoperative magnetic resonance arthrography (MRA) images were compared within or between groups. At the two-year follow-up evaluation, the SST, ASES score, UCLA score, and range of motion had significantly improved (p < 0.001 for all) in both groups. However, no significant differences were detected between groups. Even though the difference in preoperative tear size on MRA images was not significant, follow-up MRA images identified a retear in twenty patients (91%) in Group P and a significant difference in tear size between groups (p = 0.007). The complete repair group with an aggressive release had no better clinical or structural outcomes compared with the partial repair group with margin convergence alone for large-to-massive contracted rotator cuff tears. In addition, the complete repair group had a 91% retear rate and a greater defect on follow-up MRA images. Even though this study had a relatively short-term follow-up, a complete repair of large-to-massive contracted rotator cuff tears, with an aggressive release such as posterior interval slide, may not have an increased benefit compared with partial repair without posterior interval slide.

  15. Multiple Graft Harvestings from Deep Partial-Thickness Scald Wounds Healed under the Influence of Weak Direct Current

    DTIC Science & Technology

    1990-01-01

    acanthosis (H&E, 10X). FIG. 8. Scald wound of a treated animal 16 days after the second split-thickness skin graft harvesting. A) Gross appearance...that is, simply cutting the skin graft at a prede- Doctor Monafo’s questions about another model: yes, in fact, termined thickness and then

  16. Ultracompact and high efficient silicon-based polarization splitter-rotator using a partially-etched subwavelength grating coupler

    PubMed Central

    Xu, Yin; Xiao, Jinbiao

    2016-01-01

    On-chip polarization manipulation is pivotal for silicon-on-insulator material platform to realize polarization-transparent circuits and polarization-division-multiplexing transmissions, where polarization splitters and rotators are fundamental components. In this work, we propose an ultracompact and high efficient silicon-based polarization splitter-rotator (PSR) using a partially-etched subwavelength grating (SWG) coupler. The proposed PSR consists of a taper-integrated SWG coupler combined with a partially-etched waveguide between the input and output strip waveguides to make the input transverse-electric (TE) mode couple and convert to the output transverse-magnetic (TM) mode at the cross port while the input TM mode confine well in the strip waveguide during propagation and directly output from the bar port with nearly neglected coupling. Moreover, to better separate input polarizations, an additional tapered waveguide extended from the partially-etched waveguide is also added. From results, an ultracompact PSR of only 8.2 μm in length is achieved, which is so far the reported shortest one. The polarization conversion loss and efficiency are 0.12 dB and 98.52%, respectively, together with the crosstalk and reflection loss of −31.41/−22.43 dB and −34.74/−33.13 dB for input TE/TM mode at wavelength of 1.55 μm. These attributes make the present device suitable for constructing on-chip compact photonic integrated circuits with polarization-independence. PMID:27306112

  17. A Kinematic Model for Vertical Axis Rotation within the Mina Deflection of the Walker Lane

    NASA Astrophysics Data System (ADS)

    Gledhill, T.; Pluhar, C. J.; Johnson, S. A.; Lindeman, J. R.; Petronis, M. S.

    2016-12-01

    The Mina Deflection, at the boundary between the Central and Southern Walker Lane, spans the California-Nevada border and includes a heavily-faulted Pliocene volcanic field overlying Miocene ignimbrites. The dextral Walker Lane accommodates 25% of relative Pacific-North America plate motion and steps right across the sinistral Mina deflection. Ours and previous work shows that the Mina Deflection partially accommodates deformation by vertical-axis rotation of up to 99.9o ± 6.1o rotation since 11 Ma. This rotation is evident in latite ignimbrite of Gilbert et al. (1971), which we have formalized as three members of Tuff of Huntoon Creek (THC). The welded, basal, normal-polarity Huntoon Valley Member of THC is overlain by the unwelded to partially-welded, reversed-polarity Adobe Hills Mbr. This member includes internal breaks suggesting multiple eruptive phases, but the paleomagnetic results from each are statistically indistinguishable, meaning that they were likely erupted in rapid succession (within a few centuries of one another). THC ends with a welded member exhibiting very shallow inclination and south declination that we call Excursional Mbr. One of the upper members has been dated at 11.17 ± 0.04 Ma. These Miocene units are overlain by Pliocene basalts, Quaternary alluvium, and lacustrine deposits. Our paleomagnetic results show a gradient between the zero rotation domain and high rotation across a 20km baseline. A micropolar model, based on 25 years of earthquake data from the Northern and Southern California Seismic Network, suggest the Mina Deflection is currently experiencing transpressional seismogenic deformation (Unruh et al., 2003). Accepting Unruh's model and assuming continuous rotation since 11 Ma, we propose a kinematic model for the western Mina Deflection that accommodates 90o of vertical axis rotation from N-S to ENE-WSW oriented blocks.

  18. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears.

    PubMed

    Lee, Ro Woon; Choi, Soo-Jung; Lee, Man Ho; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Ki Won

    2016-12-01

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears.

  19. Non-contrast magnetic resonance imaging for diagnosing shoulder injuries.

    PubMed

    Arnold, Heino

    2012-12-01

    To compare preoperative non-contrast magnetic resonance imaging (MRI) with arthroscopy findings in diagnosing labral and rotator cuff tears. 86 men and 60 women aged 21 to 70 (mean, 52) years underwent non-contrast MRI before arthroscopic operations on the glenohumeral joint. Slices were made in a transverse, parasagittal, and paracoronar orientation. The sequences used were T2- and proton-weighted for paracoronar imaging, T1- and T2-weighted for transverse and parasagittal imaging, and T2-weigthed sequences with fat suppression and short tau inversion recovery sequences. MRI was evaluated with the surgeon to eliminate interobserver bias. Arthroscopic surgery was performed by a single surgeon. If a labral or rotator cuff tear was found, surgery was performed using corkscrew anchors. For full thickness rotator cuff tears, MRI and arthroscopy detected them in 76 and 82 patients, respectively. One such tear found by MRI could not be confirmed by arthroscopy. MRI missed 4 subscapularis and 3 supraspinatus tears. The sensitivity and specificity of MRI in diagnosing full thickness rotator cuff tears were 0.90 and 0.91, respectively. For labral tears, MRI and arthroscopy detected them in 16 and 31 patients, respectively. One anterior labral tear detected by MRI could not be verified by arthroscopy. All 16 labral tears detected by MRI were Bankart type-I tears (of the anterior glenoid) except for one superior labral tear from anterior to posterior (SLAP tear). All 13 SLAP tears (10 type 2 and 3 type 3) except for one could be found by arthroscopy only. The sensitivity and specificity of MRI in diagnosing labral tears were 0.52 and 0.89, respectively. Non-contrast MRI is reliable only for diagnosing full thickness rotator cuff tears and anterior labral tears. Direct or indirect contrast enhancement is recommended for more differentiation. Special scan orientation is necessary for SLAP tears.

  20. Arthroscopic Repair of Full-Thickness Rotator Cuff Tears With and Without Acromioplasty: Randomized Prospective Trial With 2-Year Follow-up.

    PubMed

    Abrams, Geoffrey D; Gupta, Anil K; Hussey, Kristen E; Tetteh, Elizabeth S; Karas, Vasili; Bach, Bernard R; Cole, Brian J; Romeo, Anthony A; Verma, Nikhil N

    2014-06-01

    Acromioplasty is commonly performed during arthroscopic rotator cuff repair, but its effect on short-term outcomes is debated. To report the short-term clinical outcomes of patients undergoing arthroscopic repair of full-thickness rotator cuff tears with and without acromioplasty. Randomized controlled trial; Level of evidence, 2. Patients undergoing arthroscopic repair of full-thickness rotator cuff tears were randomized into acromioplasty or nonacromioplasty groups. The Simple Shoulder Test (SST), American Shoulder and Elbow Surgeons (ASES) score, Constant score, University of California-Los Angeles (UCLA) score, and Short Form-12 (SF-12) health assessment were collected along with physical examination including range of motion and dynamometer strength testing. Intraoperative data including tear size, repair configuration, and concomitant procedures were recorded. Follow-up examination was performed at regular intervals up to 2 years. Preoperative imaging was reviewed to classify the acromial morphologic type, acromial angle, and lateral acromial angulation. A total of 114 patients were initially enrolled in the study, and 95 (83%; 43 nonacromioplasty, 52 acromioplasty) were available for a minimum 2-year follow-up. There were no significant differences in baseline characteristics, including number of tendons torn, repair configuration, concomitant procedures, and acromion type and angles. Within groups, there was a significant (P < .001) improvement in all functional outcome scores from preoperatively to all follow-up time points, including 2 years, for the nonacromioplasty and acromioplasty groups (ASES score: 55.1-91.5, 48.8-89.0; Constant score: 48.3-75.0, 51.9-78.7, respectively). There were no significant differences in functional outcomes between nonacromioplasty and acromioplasty groups or between subjects with different acromial features at any time point. The results of this study demonstrate no difference in clinical outcomes after rotator cuff repair with or without acromioplasty at 2 years postoperatively. © 2014 The Author(s).

  1. New closed analytical solutions for geometrically thick fluid tori around black holes. Numerical evolution and the onset of the magneto-rotational instability

    NASA Astrophysics Data System (ADS)

    Witzany, V.; Jefremov, P.

    2018-06-01

    Context. When a black hole is accreting well below the Eddington rate, a geometrically thick, radiatively inefficient state of the accretion disk is established. There is a limited number of closed-form physical solutions for geometrically thick (nonselfgravitating) toroidal equilibria of perfect fluids orbiting a spinning black hole, and these are predominantly used as initial conditions for simulations of accretion in the aforementioned mode. However, different initial configurations might lead to different results and thus observational predictions drawn from such simulations. Aims: We aim to expand the known equilibria by a number of closed multiparametric solutions with various possibilities of rotation curves and geometric shapes. Then, we ask whether choosing these as initial conditions influences the onset of accretion and the asymptotic state of the disk. Methods: We have investigated a set of examples from the derived solutions in detail; we analytically estimate the growth of the magneto-rotational instability (MRI) from their rotation curves and evolve the analytically obtained tori using the 2D magneto-hydrodynamical code HARM. Properties of the evolutions are then studied through the mass, energy, and angular-momentum accretion rates. Results: The rotation curve has a decisive role in the numerical onset of accretion in accordance with our analytical MRI estimates: in the first few orbital periods, the average accretion rate is linearly proportional to the initial MRI rate in the toroids. The final state obtained from any initial condition within the studied class after an evolution of ten or more orbital periods is mostly qualitatively identical and the quantitative properties vary within a single order of magnitude. The average values of the energy of the accreted fluid have an irregular dependency on initial data, and in some cases fluid with energies many times its rest mass is systematically accreted.

  2. Experimental analysis of flow structure in contra-rotating axial flow pump designed with different rotational speed concept

    NASA Astrophysics Data System (ADS)

    Cao, Linlin; Watanabe, Satoshi; Imanishi, Toshiki; Yoshimura, Hiroaki; Furukawa, Akinori

    2013-08-01

    As a high specific speed pump, the contra-rotating axial flow pump distinguishes itself in a rear rotor rotating in the opposite direction of the front rotor, which remarkably contributes to the energy conversion, the reduction of the pump size, better hydraulic and cavitation performances. However, with two rotors rotating reversely, the significant interaction between blade rows was observed in our prototype contra-rotating rotors, which highly affected the pump performance compared with the conventional axial flow pumps. Consequently, a new type of rear rotor was designed by the rotational speed optimization methodology with some additional considerations, aiming at better cavitation performance, the reduction of blade rows interaction and the secondary flow suppression. The new rear rotor showed a satisfactory performance at the design flow rate but an unfavorable positive slope of the head — flow rate curve in the partial flow rate range less than 40% of the design flow rate, which should be avoided for the reliability of pump-pipe systems. In the present research, to understand the internal flow field of new rear rotor and its relation to the performances at the partial flow rates, the velocity distributions at the inlets and outlets of the rotors are firstly investigated. Then, the boundary layer flows on rotor surfaces, which clearly reflect the secondary flow inside the rotors, are analyzed through the limiting streamline observations using the multi-color oil-film method. Finally, the unsteady numerical simulations are carried out to understand the complicated internal flow structures in the rotors.

  3. Investigations of the influence of the profile thickness of the compressible plane flow through compressor cascades

    NASA Technical Reports Server (NTRS)

    Bahr, J.

    1978-01-01

    Flow-through cascade of an aircraft turbine compressor is studied experimentally over wide range of Reynolds numbers and subsonic Mach numbers; it was found that deterioration of flow properties due to decreasing Reynolds numbers is less noticeable on thin profiles than on thick ones; however, thick profiles are advantageous in compressors designed for efficient partial load behavior because thick profiles have a relatively large range of usable inlet flow angles.

  4. Macroscopic Rotator Cuff Tendinopathy and Histopathology Do Not Predict Repair Outcomes of Rotator Cuff Tears.

    PubMed

    Sethi, Paul M; Sheth, Chirag D; Pauzenberger, Leo; McCarthy, Mary Beth R; Cote, Mark P; Soneson, Emma; Miller, Seth; Mazzocca, Augustus D

    2018-03-01

    Numerous studies have identified factors that may affect the chances of rotator cuff healing after surgery. Intraoperative tendon quality may be used to predict healing and to determine type of repair and/or consideration of augmentation. There are no data that correlate how gross tendon morphology and degree of tendinopathy affect patient outcome or postoperative tendon healing. Purpose/Hypothesis: The purposes of this study were to (1) compare the gross appearance of the tendon edge during arthroscopic rotator cuff repair with its histological degree of tendinopathy and (2) determine if gross appearance correlated with postoperative repair integrity. The hypothesis was that gross (macroscopic) tendon with normal thickness, no delamination, and elastic tissue before repair would have a correlation with low Bonar scores, higher postoperative American Shoulder and Elbow Surgeons (ASES) scores, and increased rates of postoperative tendon healing on ultrasound. Cross-sectional study; Level of evidence, 3. A total of 105 patients undergoing repair of medium-size (1-3 cm) full-thickness rotator cuff tears were enrolled in the study. Intraoperatively, the supraspinatus tendon was rated on thickness, fraying, and stiffness. Tendon tissue was recovered for histological analysis based on the Bonar scoring system. Postoperative ASES and ultrasound assessment of healing were obtained 1 year after repair. Correlation between gross appearance of the tendon and rotator cuff histology was determined. Of the 105 patients, 85 were followed the study to completion. The mean age of the patients was 61.6 years; Bonar score, 7.5; preoperative ASES score, 49; and postoperative ASES score, 86. Ninety-one percent of repairs were intact on ultrasound. Gross appearance of torn rotator cuff tendon tissue did not correlate with histological appearance. Neither histological (Bonar) score nor gross appearance correlated with multivariate analysis of ASES score, postoperative repair status, or demographic data. The degree of tendinopathy did not correlate with morphological appearance of the tendon. Neither of these parameters correlated with healing or patient outcome. This study suggests that the degree of tendinopathy, unlike muscle atrophy, may not be predictive of outcomes and that, on appearance, poor quality tendon has adequate healing capacity. Therefore, abnormal gross tendon appearance should not affect the repair effort or technique.

  5. A Computer Program to Evaluate Experimental Therapies for Treating Burned Patients

    PubMed Central

    Flora, Jairus D.; Flora, Sharyl Ann

    1980-01-01

    Determining the worth of new therapies for burn patients has been difficult because of the rarity of the burn injury and the disparate survival chances associated with different sizes of burns. Recently a burn survival model has been developed that estimates the risk of death from a burn as a function of the patient's age, sex, area of full thickness (third degree) burn, area of partial thickness burn, involvement of the perineum, and time from burn to admission. An alternative risk model uses the total area burned in place of the areas of partial thickness burn and full thickness burn, and is appropriate if the amount of full thickness burn is not determined accurately. This paper describes a program that uses these risk models to correct or standardize for demographic and severity factors, then, after that adjustment, tests whether a group of burn patients who received a new or experimental therapy shows a significantly better survival rate than that predicted by a baseline model. The program is a simple one written in Fortran for easy adaptation to other computer systems.

  6. Second-degree burns with six etiologies treated with autologous noncultured cell-spray grafting.

    PubMed

    Esteban-Vives, Roger; Choi, Myung S; Young, Matthew T; Over, Patrick; Ziembicki, Jenny; Corcos, Alain; Gerlach, Jörg C

    2016-11-01

    Partial and deep partial-thickness burn wounds present a difficult diagnosis and prognosis that makes the planning for a conservative treatment versus mesh grafting problematic. A non-invasive treatment strategy avoiding mesh grafting is often chosen by practitioners based on their clinical and empirical evidence. However, a delayed re-epithelialization after conservative treatment may extend the patient's hospitalization period, increase the risk of infection, and lead to poor functional and aesthetic outcome. Early spray grafting, using non-cultured autologous cells, is under discussion for partial and deep partial-thickness wounds to accelerate the re-epithelialization process, reducing the healing time in the hospital, and minimizing complications. To address planning for future clinical studies on this technology, suitable indications will be interesting. We present case information on severe second-degree injuries after gas, chemical, electrical, gasoline, hot water, and tar scalding burns showing one patient per indication. The treatment results with autologous non-cultured cells, support rapid, uncomplicated re-epithelialization with aesthetically and functionally satisfying outcomes. Hospital stays averaged 7.6±1.6 days. Early autologous cell-spray grafting does not preclude or prevent simultaneous or subsequent traditional mesh autografting when indicated on defined areas of full-thickness injury. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  7. Terahertz disorder-localized rotational modes and lattice vibrational modes in the orientationally-disordered and ordered phases of camphor.

    PubMed

    Nickel, Daniel V; Ruggiero, Michael T; Korter, Timothy M; Mittleman, Daniel M

    2015-03-14

    The temperature-dependent terahertz spectra of the partially-disordered and ordered phases of camphor (C10H16O) are measured using terahertz time-domain spectroscopy. In its partially-disordered phases, a low-intensity, extremely broad resonance is found and is characterized using both a phenomenological approach and an approach based on ab initio solid-state DFT simulations. These two descriptions are consistent and stem from the same molecular origin for the broad resonance: the disorder-localized rotational correlations of the camphor molecules. In its completely ordered phase(s), multiple lattice phonon modes are measured and are found to be consistent with those predicted using solid-state DFT simulations.

  8. Moist occlusive dressing (Aquacel(®) Ag) versus moist open dressing (MEBO(®)) in the management of partial-thickness facial burns: a comparative study in Ain Shams University.

    PubMed

    Mabrouk, Amr; Boughdadi, Nahed Samir; Helal, Hesham A; Zaki, Basim M; Maher, Ashraf

    2012-05-01

    The face is the central point of the physical features; it transmits expressions and emotions, communicates feelings and allows for individual identity. Facial burns are very common and are devastating to the affected patient and results into numerous physical, emotional and psychosocial sequels. Partial thickness facial burns are very common especially among children. This study compares the effect of standard moist open technique management and a moist closed technique for partial thickness burns of the face. Patients with partial-thickness facial burns admitted in the burn unit, Ain Shams University, Cairo, Egypt in the period from April 2009 to December 2009 were included in this study. They were divided into two groups to receive either open treatment with MEBO(®) (n=20) or coverage with Aquacel(®) Ag (n=20). Demographics (age, gender, ethnicity, TBSA, burn areas), length of hospital stay (LOS), rate of infections, time to total healing, frequency of dressing changes, pain, cost benefit and patient discomfort were compared between the two groups. The long-term outcome (incidence of hypertrophic scarring) was assessed for up to 6 months follow-up period. There were no significant differences in demographics between the two groups. In the group treated with the Aquacel(®) Ag, the mean time for re-epithelialization was 10.5 days, while it was 12.4 days in the MEBO(®) group (p<0.05). Frequency of changes, pain and patient discomfort were less with Aquacel(®) Ag. Cost was of no significant difference between the two groups. Scar quality improved in the Aquacel(®) Ag treatment group. Three and 6 months follow-up was done and long-term outcomes were recorded in both groups. Moist occlusive dressing (Aquacel(®) Ag) significantly improves the management and healing rate of partial thickness facial burns with better long-term outcome compared to moist open dressing (MEBO(®)). Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.

  9. Cost-effectiveness of silver dressings for paediatric partial thickness burns: An economic evaluation from a randomized controlled trial.

    PubMed

    Gee Kee, E; Stockton, K; Kimble, R M; Cuttle, L; McPhail, S M

    2017-06-01

    Partial thickness burns of up to 10% total body surface area (TBSA) in children are common injuries primarily treated in the outpatient setting using expensive silver-containing dressings. However, economic evaluations in the paediatric burns population are lacking to assist healthcare providers when choosing which dressing to use. The aim of this study was to conduct a cost-effectiveness analysis of three silver dressings for partial thickness burns ≤10% TBSA in children aged 0-15 years using days to full wound re-epithelialization as the health outcome. This study was a trial based economic evaluation (incremental cost effectiveness) conducted from a healthcare provider perspective. Ninety-six children participated in the trial investigating Acticoat™, Acticoat™ with Mepitel™ or Mepilex Ag™. Costs directly related to the management of partial thickness burns ≤10% TBSA were collected during the trial from March 2013 to July 2014 and for a one year after re-epithelialization time horizon. Incremental cost effectiveness ratios were estimated and dominance probabilities calculated from bootstrap resampling trial data. Sensitivity analyses were conducted to examine the potential effect of accounting for infrequent, but high cost, skin grafting surgical procedures. Costs (dressing, labour, analgesics, scar management) were considerably lower in the Mepilex Ag™ group (median AUD$94.45) compared to the Acticoat™ (median $244.90) and Acticoat™ with Mepitel™ (median $196.66) interventions. There was a 99% and 97% probability that Mepilex Ag™ dominated (cheaper and more effective than) Acticoat™ and Acticoat™ with Mepitel™, respectively. This pattern of dominance was consistent across raw cost and effects, after a priori adjustments, and sensitivity analyses. There was an 82% probability that Acticoat™ with Mepitel dominated Acticoat™ in the primary analysis, although this probability was sensitive to the effect of skin graft procedures. This economic evaluation has demonstrated that Mepilex Ag™ was the dominant dressing choice over both Acticoat™ and Acticoat™ with Mepitel™ in this trial-based economic evaluation and is recommended for treatment of paediatric partial thickness burns ≤10% TBSA. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  10. Pool film boiling from rotating and stationary spheres in liquid nitrogen. [for SSME turbopump ball bearings

    NASA Technical Reports Server (NTRS)

    Cuan, Winston M.; Schwartz, Sidney H.

    1988-01-01

    Results are presented for a preliminary experiment involving a saturated pool boiling at 1 atm from rotating 2 and 3 inch diameter spheres which were immersed in LN2. Additional results are presented for a stationary 2 inch diameter sphere quenched in LN2, which were obtained with a more versatile and complete experimental apparatus. The speed of the rotational tests varied from 0 to 10,000 rpm. The stationary experiments parametrically varied pressure and subcooling levels from 0 to 600 psig and from 0 to 50 F, respectively. During the rotational tests, a high speed photographic analysis was undertaken to measure the thickness of the vapor film surrounding the sphere.

  11. Management of In-Season Concurrent Rotator Cuff Tear With Shoulder Instability in Professional Contact Football Athletes; Respect the Career Goals!

    PubMed Central

    Mueller, Maike; Hoy, Gregory; Branson, Ruben

    2016-01-01

    Introduction Professional sports injuries are usually all dealt with at one single operation to return the player to the sport after appropriate rehabilitation. We questioned the assumption that rotator cuff tears must be repaired concurrently with instability syndromes, and aimed to allow a professional rugby league player to achieve career goals by NOT correcting all pathology at one surgery. Case Presentation A professional rugby league player presented with acute shoulder instability on a setting of a chronic full thickness rotator cuff tear. We performed an “in season” arthroscopic stabilization on an elite rugby league player, leaving a previously diagnosed large full thickness rotator cuff tear untreated. This allowed aggressive rehabilitation and return to contact competition at 12 weeks post-surgery. The player achieved a long held career goal of winning a premiership ring before undertaking rotator cuff repair at the end of the season. Latest follow up at seven years (still at elite level) demonstrated an asymptomatic shoulder. Conclusions The assumption that all pathology found at surgical exploration requires correction to play at elite level is not universally correct. We postulate that whilst rotator cuff deficiency has severe long-term sequelae, it is shoulder instability alone that prevents high level contact sports participation. Career goal management is an important part of managing elite level athletes. We have demonstrated that by careful management of the specific pathology preventing participation can allow elite athletes to achieve career goals without compromising long-term health. PMID:27217928

  12. A Pilot Study of the Efficacy of Active Leptospermum Honey for the Treatment of Partial-Thickness Facial Burns.

    PubMed

    Duncan, Christina L; Enlow, Paul T; Szabo, Margo M; Tolchin, Eric; Kelly, Robert W; Castanon, Lourdes; Aballay, Ariel M

    2016-08-01

    Research suggests that active Leptospermum honey (ALH) improves outcomes in patients with partial-thickness burns by enhancing healing and reepithelialization rates, as well as by protecting against antibiotic-resistant microorganisms. This study assessed the effectiveness of ALH gel on healing time, bacterial growth, patient satisfaction, and cost of treatment. Single-arm, prospective case series. Seven patients (aged 7-64 years) with partial-thickness facial burns were recruited from a northeastern US burn center. All patients cleansed their wounds daily with soap and water, after which they applied ALH gel. Three physicians independently rated healing using wound photography and daily tests for the presence of exudate. Wound cultures on days 1 and 7 (±2 days) assessed bacterial growth. Patients completed a satisfaction survey at the end of treatment, and cost of treatment was calculated. Healing time ranged from 3 to 14 days (mean, 8.1 days). Wound cultures revealed normal bacterial growth on days 1 and 7 for all patients. Patients rated ALH gel favorably, with the most common complaint of stickiness in 5 patients. One patient experienced transient burning on application that did not interrupt treatment. Average hospital-based cost of treatment was $26.15 per patient. Healing time was congruent with or better than what would have been expected with standard treatment. Furthermore, despite no antibiotic treatment, wound culture results yielded no abnormal bacterial growth. Finally, patients overall reported satisfaction with treatment. The findings of this study suggest that ALH is a clinically and economically valuable treatment for partial-thickness facial burns.

  13. Impact of deposition-rate fluctuations on thin-film thickness and uniformity

    DOE PAGES

    Oliver, Joli B.

    2016-11-04

    Variations in deposition rate are superimposed on a thin-film–deposition model with planetary rotation to determine the impact on film thickness. Variations in magnitude and frequency of the fluctuations relative to the speed of planetary revolution lead to thickness errors and uniformity variations up to 3%. Sufficiently rapid oscillations in the deposition rate have a negligible impact, while slow oscillations are found to be problematic, leading to changes in the nominal film thickness. Finally, superimposing noise as random fluctuations in the deposition rate has a negligible impact, confirming the importance of any underlying harmonic oscillations in deposition rate or source operation.

  14. Aligning flaky FeSiAl particles with a two-dimensional rotating magnetic field to improve microwave-absorbing and shielding properties of composites

    NASA Astrophysics Data System (ADS)

    Liu, Chang; Cai, Jun; Duan, Yubing; Li, Xinghao; Zhang, Deyuan

    2018-07-01

    In order to enhance the microwave-absorbing and shielding properties of the composites, the flaky FeSiAl particles embedded in an epoxy polymer were aligned with a two-dimensional rotating magnetic field. The morphologies, electromagnetic (EM) characteristics, and microwave-absorbing and shielding properties of the unaligned and aligned FeSiAl/epoxy composites were investigated. The results showed that after alignment treatment, the flaky FeSiAl particles tend to orient uniformly in the rotating magnetic field, and the permittivity and permeability of the aligned composites were increased in the frequency range of 1-18 GHz compared with that of randomly distributed composites. The calculated microwave-absorbing properties indicated that the peak value of the return loss (RL) of the aligned composites can reach 8.8 dB, compared with 5.8 dB of the unaligned composites of 2.5 mm in thickness (60 wt%); and the bandwidth with RL value more than 6 dB is in a wider frequency range from 1 to 2.8 GHz. And the calculated shielding effectiveness (SE) of the aligned composites is 1.1-3 times higher than that of unaligned one in every thickness, and the maximum SE of the aligned one is 31.8 dB at 18 GHz with a thickness of 2.5 mm.

  15. Extended lateral thoracic fasciocutaneous biosynthetic flap for reconstruction of full-thickness partial external ear defects: an experimental study.

    PubMed

    Kuvat, Samet Vasfi; Taşkın, Ümit; Yücebaş, Kadir; Tansuker, Hasan Deniz; Oktay, Mehmet Faruk; Kozanoğlu, Erol; Aydın, Salih

    2017-01-01

    External ear reconstruction is a controversial topic in reconstructive plastic surgery. Here, we prepared a pedicled biosynthetic flap for full-thickness, partial ear defects in rabbits. We operated on six adult female New Zealand rabbits weighing 3-4 kg. The dimensions of the lateral thoracic fasciocutaneous flap were 7 × 6 cm. The flap was elevated based on one of the bilaterally located internal thoracic arteries, which were dissected proximally. The pedicled flap was folded in two, and polypropylene mesh was sandwiched in the middle. The flap was adapted to a defect of 3.5 × 3 cm in diameter. In fact, the defect was created before elevation of the flap. Rabbits were followed up for 4 weeks, at the end of which they were killed and their ears were evaluated histopathologically. The survival rate of the rabbits was 100 %. All pedicled biosynthetic flaps were viable, but one showed partial (20 %) necrosis (1/6) and one was partially detached (1/6). Macroscopic (color, thickness, texture) and histological (polymorphonuclear leukocyte invasion in the skin, subcutaneous tissue, and at the junction between the polypropylene mesh and the flap) features of the flap were compared to the ipsilateral ear. A new technique was developed for partial external ear reconstruction with sufficient inner skeletal support and outer skin lining. Level of evidence Level NA.

  16. Radiography and partial tomography of wood with thermal neutrons

    NASA Astrophysics Data System (ADS)

    Osterloh, K.; Fratzscher, D.; Schwabe, A.; Schillinger, B.; Zscherpel, U.; Ewert, U.

    2011-09-01

    The effective high neutron scattering absorption coefficient of hydrogen (48.5 cm 2/g) due to the scattering allows neutrons to reveal hydrocarbon structures with more contrast than X-rays, but at the same time limits the sample size and thickness that can be investigated. Many planar shaped objects, particularly wood samples, are sufficiently thin to allow thermal neutrons to transmit through the sample in a direction perpendicular to the planar face but not in a parallel direction, due to increased thickness. Often, this is an obstacle that prevents some tomographic reconstruction algorithms from obtaining desired results because of inadequate information or presence of distracting artifacts due to missing projections. This can be true for samples such as the distribution of glue in glulam (boards of wooden layers glued together), or the course of partially visible annual rings in trees where the features of interest are parallel to the planar surface of the sample. However, it should be possible to study these features by rotating the specimen within a limited angular range. In principle, this approach has been shown previously in a study with fast neutrons [2]. A study of this kind was performed at the Antares facility of FRM II in Garching with a 2.6×10 7/cm 2 s thermal neutron beam. The limit of penetration was determined for a wooden step wedge carved from a 2 cm×4 cm block of wood in comparison to other materials such as heavy metals and Lucite as specimens rich in hydrogen. The depth of the steps was 1 cm, the height 0.5 cm. The annual ring structures were clearly detectable up to 2 cm thickness. Wooden specimens, i.e. shivers, from a sunken old ship have been subjected to tomography. Not visible from the outside, clear radial structures have been found that are typical for certain kinds of wood. This insight was impaired in a case where the specimen had been soaked with ethylene glycol. In another large sample study, a planar board made of glulam has been studied to show the glued layers. This study shows not only the limits of penetration in wood but also demonstrates access to structures perpendicular to the surface in larger planar objects by tomography with fast neutrons, even with incomplete sets of projection data that covers an angular range of only 90° or even 60°.

  17. Paleoslumps in coal-bearing strata of the Breathitt Group (Pennsylvanian), Eastern Kentucky Coal Field, U.S.A

    USGS Publications Warehouse

    Greb, S.F.; Weisenfluh, G.A.

    1996-01-01

    The benefits of geologic analysis for roof-control studies and hazard prediction in coal mines are well documented. Numerous case studies have illustrated the importance of recognizing geologic features such as paleochannels, coal riders, and kettlebottoms in mine roofs. Relatively understudied features, in terms of mining, are paleoslumps. Paleoslumps represent ancient movement and rotation of semi-consolidated sediment. Because bedding in paleoslumps is deformed or inclined, these features cause instability in mine roofs, haul roads, surface highwalls, and other excavations. Various types of paleoslumps above coals in the Eastern Kentucky Coal Field were studied in order to aid in their recognition and prediction in mines. The paleoslumps studied all showed characteristic slump-deformation features, although some differences in magnitude of deformation and overall slump size were noted. Coals beneath slumps often exhibited folding, reverse displacements, truncation, clastic dikes, and locally increased thickness. Slumps are inferred to have been triggered by a wide range of mechanisms, such as loading of water-saturated sediment on rigid substrates, synsedimentary faulting, and over-pressurization of channel margin and bar slopes. Analysis of paleoslumps in underground mines, where paleoslumps are viewed from beneath rather than in profile is difficult, since characteristic bed rotation may not be conspicuous. Sudden increases in bed-dip angle inferred from changes in rock type or bedding contacts in the roof; occurrence of bounding, polished rotation surfaces; or roof irregularity and occurrence of loading features may indicate the presence of paleoslumps. Another key to recognition may be the sudden appearance of over-thickened coal, which can occur because of slump-created paleotopography, synsedimentary faults, and slump-generated overthrusting. In addition, steeply inclined, folded, or transported coal marginal to paleoslumps can create apparent increases in coal thickness in cores. Although thick coals are obviously a target of exploration, anomalously thick coals may actually indicate adjacent paleoslumps accompanied by hazardous roof conditions and loss of seam thickness.

  18. Assessment and characterization of in situ rotator cuff biomechanics

    NASA Astrophysics Data System (ADS)

    Trent, Erika A.; Bailey, Lane; Mefleh, Fuad N.; Raikar, Vipul P.; Shanley, Ellen; Thigpen, Charles A.; Dean, Delphine; Kwartowitz, David M.

    2013-03-01

    Rotator cuff disease is a degenerative disorder that is a common, costly, and often debilitating, ranging in severity from partial thickness tear, which may cause pain, to total rupture, leading to loss in function. Currently, clinical diagnosis and determination of disease extent relies primarily on subjective assessment of pain, range of motion, and possibly X-ray or ultrasound images. The final treatment plan however is at the discretion of the clinician, who often bases their decision on personal experiences, and not quantitative standards. The use of ultrasound for the assessment of tissue biomechanics is established, such as in ultrasound elastography, where soft tissue biomechanics are measured. Few studies have investigated the use of ultrasound elastography in the characterization of musculoskeletal biomechanics. To assess tissue biomechanics we have developed a device, which measures the force applied to the underlying musculotendentious tissue while simultaneously obtaining the related ultrasound images. In this work, the musculotendinous region of the infraspinatus of twenty asymptomatic male organized baseball players was examined to access the variability in tissue properties within a single patient and across a normal population. Elastic moduli at percent strains less than 15 were significantly different than those above 15 percent strain within the normal population. No significant difference in tissue properties was demonstrated within a single patient. This analysis demonstrated elastic moduli are variable across individuals and incidence. Therefore threshold elastic moduli will likely be a function of variation in local-tissue moduli as opposed to a specific global value.

  19. INTEGRITY OF THE SUBSCAPULARIS TENDON AFTER OPEN SURGERY FOR THE TREATMENT OF ANTERIOR SHOULDER INSTABILITY: A CLINICAL AND RADIOLOGICAL EVALUATION

    PubMed Central

    Lech, Osvandré; Piluski, Paulo; Tambani, Renato; Castro, Nero; Pimentel, Gilnei

    2015-01-01

    Objective: To evaluate the integrity of the subscapularis tendon by strength, function and magnetic resonance imaging after deltopectoralis access for anterior shoulder instability. Methods: 20 patients with anterior shoulder instability have been evaluated. Minimum follow-up was 12 months, with a mean of 40 months. Only male patients were included, with a mean of age of 29 years (20 − 42 years). The patients have been submitted to physical examinations of mobility, muscular strength, Belly Test and Gerber Test. The isokinetic strength in internal and external rotation, in angular speeds of 600/s and 1800/s, for both shoulders was measured using a dynamometer. In 15 patients magnetic resonance imaging (MRI) was carried out on both shoulders for evaluating the thickness, cross-sectional area and atrophy of the subscapularis muscle. Results: A significant difference was found between torque peaks at the speed of 600/s for internal (p=0.036) and external (p=0.008) rotation. However, at 1800/s the opposite happens (internal rotation: p=0.133; external rotation: p=0.393). Subscapularis muscle thickness and area are significantly smaller than the normal side, with a deficit of 19% and 23%, respectively. According to Rowe and UCLA scores, we find excellent and good results for the majority of patients, with a mean of 88 and 31.6 points, respectively. Conclusion: Despite of the good functional results, open surgery can limit strength and reduce the thickness and the cross-sectional area of subscapularis muscle. However, the best results were found in the patients who had the dominant side operated. PMID:27004190

  20. Effect of metallic walls on dynamos generated by laminar boundary-driven flow in a spherical domain.

    PubMed

    Guervilly, Céline; Wood, Toby S; Brummell, Nicholas H

    2013-11-01

    We present a numerical study of dynamo action in a conducting fluid encased in a metallic spherical shell. Motions in the fluid are driven by differential rotation of the outer metallic shell, which we refer to as "the wall." The two hemispheres of the wall are held in counter-rotation, producing a steady, axisymmetric interior flow consisting of differential rotation and a two-cell meridional circulation with radial inflow in the equatorial plane. From previous studies, this type of flow is known to maintain a stationary equatorial dipole by dynamo action if the magnetic Reynolds number is larger than about 300 and if the outer boundary is electrically insulating. We vary independently the thickness, electrical conductivity, and magnetic permeability of the wall to determine their effect on the dynamo action. The main results are the following: (a) Increasing the conductivity of the wall hinders the dynamo by allowing eddy currents within the wall, which are induced by the relative motion of the equatorial dipole field and the wall. This processes can be viewed as a skin effect or, equivalently, as the tearing apart of the dipole by the differential rotation of the wall, to which the field lines are anchored by high conductivity. (b) Increasing the magnetic permeability of the wall favors dynamo action by constraining the magnetic field lines in the fluid to be normal to the wall, thereby decoupling the fluid from any induction in the wall. (c) Decreasing the wall thickness limits the amplitude of the eddy currents, and is therefore favorable for dynamo action, provided that the wall is thinner than the skin depth. We explicitly demonstrate these effects of the wall properties on the dynamo field by deriving an effective boundary condition in the limit of vanishing wall thickness.

  1. Crustal Thickness Beneath Libya and the Origin of Partial Melt Beneath AS Sawda Volcanic Province From Receiver Function Constraints

    NASA Astrophysics Data System (ADS)

    Lemnifi, Awad A.; Elshaafi, Abdelsalam; Browning, John; Aouad, Nassib S.; El Ebaidi, Saad K.; Liu, Kelly K.; Gudmundsson, Agust

    2017-12-01

    This study investigates crustal thickness and properties within the Libyan region. Results obtained from 15 seismic stations belonging to the Libyan Center for Remote Sensing and Space Science are reported, in addition to 3 seismic stations publically available, using receiver functions. The results show crustal thicknesses ranging from 24 km to 36 km (with uncertainties ranging between ±0.10 km and ±0.90 km). More specifically, crustal thickness ranges from 32 km to 36 km in the southern portion of the Libyan territory then becomes thinner, between 24 km and 30 km, in the coastal areas of Libya and thinnest, between 24 km and 28 km, in the Sirt Basin. The observed high Vp/Vs value of 1.91 at one station located at the AS Sawda Volcanic Province in central Libya indicates the presence of either partial melt or an abnormally warm area. This finding suggests that magma reservoirs beneath the Libyan territory may still be partially molten and active, thereby posing significant earthquake and volcanic risks. The hypothesis of an active magma source is further demonstrated though the presence of asthenospheric upwelling and extension of the Sirt Basin. This study provides a new calculation of unconsolidated sediment layers by using the arrival time of the P to S converted phases. The results show sediments thicknesses of 0.4 km to 3.7 km, with the Vp/Vs values ranging from 2.2 to 4.8. The variations in crustal thickness throughout the region are correlated with surface elevation and Bouguer gravity anomalies, which suggest that they are isostatically compensated.

  2. Growth factors in porcine full and partial thickness burn repair. Differing targets and effects of keratinocyte growth factor, platelet-derived growth factor-BB, epidermal growth factor, and neu differentiation factor.

    PubMed Central

    Danilenko, D. M.; Ring, B. D.; Tarpley, J. E.; Morris, B.; Van, G. Y.; Morawiecki, A.; Callahan, W.; Goldenberg, M.; Hershenson, S.; Pierce, G. F.

    1995-01-01

    The topical application of recombinant growth factors such as epidermal growth factor, platelet-derived growth factor-BB homodimer (rPDGF-BB), keratinocyte growth factor (rKGF), and neu differentiation factor has resulted in significant acceleration of healing in several animal models of wound repair. In this study, we established highly reproducible and quantifiable full and deep partial thickness porcine burn models in which burns were escharectomized 4 or 5 days postburn and covered with an occlusive dressing to replicate the standard treatment in human burn patients. We then applied these growth factors to assess their efficacy on several parameters of wound repair: extracellular matrix and granulation tissue production, percent reepithelialization, and new epithelial area. In full thickness burns, only rPDGF-BB and the combination of rPDGF-BB and rKGF induced significant changes in burn repair. rPDGF-BB induced marked extracellular matrix and granulation tissue production (P = 0.013) such that the burn defect was filled within several days of escharectomy, but had no effect on new epithelial area or reepithelialization. The combination of rPDGF-BB and rKGF in full thickness burns resulted in a highly significant increase in extracellular matrix and granulation tissue area (P = 0.0009) and a significant increase in new epithelial area (P = 0.007), but had no effect on reepithelialization. In deep partial thickness burns, rKGF induced the most consistent changes. Daily application of rKGF induced a highly significant increase in new epithelial area (P < 0.0001) but induced only a modest increase in reepithelialization (83.7% rKGF-treated versus 70.2% control; P = 0.016) 12 days postburn. rKGF also doubled the number of fully reepithelialized burns (P = 0.02) at 13 days postburn, at least partially because of marked stimulation of both epidermal and follicular proliferation as assessed by proliferating cell nuclear antigen expression. In situ hybridization for KGFR in porcine burns revealed strong expression of KGFR on hair follicles and basal epidermis, confirming direct rKGF action on follicular as well as epidermal keratinocytes. Although the epithelial proliferation induced by rKGF resulted in marked neoepidermal psoriasiform hyperplasia with exaggerated rete ridges and neoepidermal and follicular maturation as assessed by expression of cytokeratin 10, a marker of keratinocyte terminal differentiation was not delayed and appeared to be accelerated in some rKGF-treated burns. Recombinant epidermal growth factor induced a trend toward increased new epithelial area in deep partial thickness burns, but had no effect on reepithelialization. The recombinant neu differentiation factor-alpha 2 isoform had no significant biological effects in either full or deep partial thickness burns.(ABSTRACT TRUNCATED AT 250 WORDS) Images Figure 1 Figure 2 Figure 4 Figure 7 Figure 8 PMID:7485390

  3. An all-reflective polarization rotator

    NASA Astrophysics Data System (ADS)

    Bohus, J.; Budai, Judit; Kalashnikov, M.; Osvay, K.

    2017-05-01

    The conceptual design and proof of principle experimental results of a polarization rotator based on mirrors are presented. The device is suitable for any-angle, online rotation of the plane of polarization of high peak intensity ultrashort laser pulses. Controllable rotation of the polarization vector of short laser pulses with a broad bandwidth requires achromatic retarding plates which have a limited scalability and the substantial plate thickness can lead to pulse broadening and inaccurate polarization rotation. Polarization rotators based on reflective optical elements are preferable alternatives to wave plates especially when used in high average power or high peak intensity ultra-short laser systems. The control of the polarization state is desirable in many laser-matter interaction experiments e.g., high harmonic and attosecond pulse generation, electron, proton and ion acceleration, electron-positron pair creating, vacuum nonlinear polarization effect. The device can also serve as a beam attenuator, in combination with a linear polarizer.

  4. Pool boiling from rotating and stationary spheres in liquid nitrogen

    NASA Technical Reports Server (NTRS)

    Cuan, Winston M.; Schwartz, Sidney H.

    1988-01-01

    Results are presented for a preliminary experiment involving saturated pool boiling at 1 atm from rotating 2 and 3 in. diameter spheres which were immersed in liquid nitrogen (LN2). Additional results are presented for a stationary, 2 inch diameter sphere, quenched in LN2, which were obtained utilizing a more versatile and complete experimental apparatus that will eventually be used for additional rotating sphere experiments. The speed for the rotational tests was varied from 0 to 10,000 rpm. The stationary experiments parametrically varied pressure and subcooling levels from 0 to 600 psig and from 0 to 50 F, respectively. During the rotational tests, a high speed photographic analysis was undertaken to measure the thickness of the vapor film surrounding the sphere. The average Nusselt number over the cooling period was plotted against the rotational Reynolds number. Stationary sphere results included local boiling heat transfer coefficients at different latitudinal locations, for various pressure and subcooling levels.

  5. The Gradual Expansion Muscle Flap

    DTIC Science & Technology

    2014-01-01

    acute shortening and angulation of the tibia and rotational muscle flap coverage and split thickness skin grafting of the soft tissue defect...is also amenable to split-thickness skin grafting after tissue incorporation.11 In addition to donor site morbidity, free tissue transfer is dependent...necessary soft tissue coverage. In the second stage, after the flap has adequately set and overlying skin graft has full adherence, a Taylor Spatial

  6. Spatial Distribution of Oxygen Chemical Potential under Potential Gradients and Theoretical Maximum Power Density with 8YSZ Electrolyte

    NASA Astrophysics Data System (ADS)

    Lim, Dae-Kwang; Im, Ha-Ni; Song, Sun-Ju

    2016-01-01

    The maximum power density of SOFC with 8YSZ electrolyte as the function of thickness was calculated by integrating partial conductivities of charge carriers under various DC bias conditions at a fixed oxygen chemical potential gradient at both sides of the electrolyte. The partial conductivities were successfully taken using the Hebb-Wagner polarization method as a function of temperature and oxygen partial pressure, and the spatial distribution of oxygen partial pressure across the electrolyte was calculated based on Choudhury and Patterson’s model by considering zero electrode polarization. At positive voltage conditions corresponding to SOFC and SOEC, the high conductivity region was expanded, but at negative cell voltage condition, the low conductivity region near n-type to p-type transition was expanded. In addition, the maximum power density calculated from the current-voltage characteristic showed approximately 5.76 W/cm2 at 700 oC with 10 μm thick-8YSZ, while the oxygen partial pressure of the cathode and anode sides maintained ≈0.21 and 10-22 atm.

  7. Polygons on a rotating fluid surface.

    PubMed

    Jansson, Thomas R N; Haspang, Martin P; Jensen, Kåre H; Hersen, Pascal; Bohr, Tomas

    2006-05-05

    We report a novel and spectacular instability of a fluid surface in a rotating system. In a flow driven by rotating the bottom plate of a partially filled, stationary cylindrical container, the shape of the free surface can spontaneously break the axial symmetry and assume the form of a polygon rotating rigidly with a speed different from that of the plate. With water, we have observed polygons with up to 6 corners. It has been known for many years that such flows are prone to symmetry breaking, but apparently the polygonal surface shapes have never been observed. The creation of rotating internal waves in a similar setup was observed for much lower rotation rates, where the free surface remains essentially flat [J. M. Lopez, J. Fluid Mech. 502, 99 (2004). We speculate that the instability is caused by the strong azimuthal shear due to the stationary walls and that it is triggered by minute wobbling of the rotating plate.

  8. Rotator cuff tendinopathy: a model for the continuum of pathology and related management.

    PubMed

    Lewis, Jeremy S

    2010-10-01

    Pathology of the soft tissues of the shoulder including the musculotendinous rotator cuff and subacromial bursa are extremely common and are a principal cause of pain and suffering. Competing theories have been proposed to explain the pathoaetiology of rotator cuff pathology at specific stages and presentations of the condition. This review proposes a model to describe the continuum of the rotator cuff pathology from asymptomatic tendon through full thickness rotator cuff tears. The pathoaetiology of rotator cuff failure is multifactorial and results from a combination of intrinsic, extrinsic and environmental factors. Recently a new and generic model detailing the continuum of tendon pathology has been proposed. This model is relevant for the rotator cuff and provides a framework to stage the continuity of rotator cuff pathology. Furthermore, it provides a structure to identify the substantial deficiencies in our knowledge base and areas where research would improve our understanding of the pathological and repair process, together with assessment and management. The strength of this model adapted for the rotator cuff tendons and subacromial bursa will be tested in its ability to incorporate and adapt to emerging research.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghafarian, M.; Ariaei, A., E-mail: ariaei@eng.ui.ac.ir

    The free vibration analysis of a multiple rotating nanobeams' system applying the nonlocal Eringen elasticity theory is presented. Multiple nanobeams' systems are of great importance in nano-optomechanical applications. At nanoscale, the nonlocal effects become non-negligible. According to the nonlocal Euler-Bernoulli beam theory, the governing partial differential equations are derived by incorporating the nonlocal scale effects. Assuming a structure of n parallel nanobeams, the vibration of the system is described by a coupled set of n partial differential equations. The method involves a change of variables to uncouple the equations and the differential transform method as an efficient mathematical technique tomore » solve the nonlocal governing differential equations. Then a number of parametric studies are conducted to assess the effect of the nonlocal scaling parameter, rotational speed, boundary conditions, hub radius, and the stiffness coefficients of the elastic interlayer media on the vibration behavior of the coupled rotating multiple-carbon-nanotube-beam system. It is revealed that the bending vibration of the system is significantly influenced by the rotational speed, elastic mediums, and the nonlocal scaling parameters. This model is validated by comparing the results with those available in the literature. The natural frequencies are in a reasonably good agreement with the reported results.« less

  10. EFFECT OF CHERENKOV LIGHT POLARIZATION ON TOTAL REFLECTION COUNTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, J.D.; Duteil, P.; Leontic, B.

    1963-01-01

    A rugged total internal reflection counter with a 3- to 5cm thick compact radiator was used at the CERN proton synchrotron for beam analysis. The threshold behavior of this counter was compared when filled with glycerol and with turpentine. Turpentine is optically active and rotates the plane of polarization about 7 un. Concent 85% /cm. Figures illustrate the effect of this polarization rotation. (A.G.W.)

  11. A high yield neutron target for cancer therapy

    NASA Technical Reports Server (NTRS)

    Alger, D. L.; Steinberg, R.

    1972-01-01

    A rotating target was developed that has the potential for providing an initial yield of 10 to the 13th power neutrons per second by the T(d,n)He-4 reaction, and a useable lifetime in excess of 600 hours. This yield and lifetime are indicated for a 300 Kv and 30 mA deuteron accelerator and a 30 microns thick titanium tritide film formed of the stoichiometric compound TiT2. The potential for extended lifetime is made possible by incorporating a sputtering electrode that permits use of titanium tritide thicknesses much greater than the deuteron range. The electrode is used to remove in situ depleted titanium layers to expose fresh tritide beneath. The utilization of the rotating target as a source of fast neutrons for cancer therapy is discussed.

  12. High power water load for microwave and millimeter-wave radio frequency sources

    DOEpatents

    Ives, R. Lawrence; Mizuhara, Yosuke M.; Schumacher, Richard V.; Pendleton, Rand P.

    1999-01-01

    A high power water load for microwave and millimeter wave radio frequency sources has a front wall including an input port for the application of RF power, a cylindrical dissipation cavity lined with a dissipating material having a thickness which varies with depth, and a rear wall including a rotating reflector for the reflection of wave energy inside the cylindrical cavity. The dissipation cavity includes a water jacket for removal of heat generated by the absorptive material coating the dissipation cavity, and this absorptive material has a thickness which is greater near the front wall than near the rear wall. Waves entering the cavity reflect from the rotating reflector, impinging and reflecting multiple times on the absorptive coating of the dissipation cavity, dissipating equal amounts of power on each internal reflection.

  13. Simulations of the kinematic dynamo onset of spherical Couette flows with smooth and rough boundaries.

    PubMed

    Finke, K; Tilgner, A

    2012-07-01

    We study numerically the dynamo transition of an incompressible electrically conducting fluid filling the gap between two concentric spheres. In a first series of simulations, the fluid is driven by the rotation of a smooth inner sphere through no-slip boundary conditions, whereas the outer sphere is stationary. In a second series a volume force intended to simulate a rough surface drives the fluid next to the inner sphere within a layer of thickness one-tenth of the gap width. We investigate the effect of the boundary layer thickness on the dynamo threshold in the turbulent regime. The simulations show that the boundary forcing simulating the rough surface lowers the necessary rotation rate, which may help to improve spherical dynamo experiments.

  14. Prolateness of the Solar Tachocline Inferred from Latitudinal Force Balance in a Magnetohydrodynamic Shallow-Water Model

    NASA Astrophysics Data System (ADS)

    Dikpati, Mausumi; Gilman, Peter A.

    2001-05-01

    Motivated by recent helioseismic observations concerning solar tachocline shape and thickness and by the theoretical development of MHD shallow-water equations for the tachocline, we compute the prolateness of the tachocline using an MHD shallow-water model, in which the shape and thickness are determined from the latitudinal force balance equation. We show that a strong toroidal magnetic field stored at or below the overshoot part of the tachocline leads to a pileup of fluid at high latitude, owing to the poleward magnetic curvature stress which has to be balanced by an equatorward latitudinal hydrostatic pressure gradient. For toroidal fields of solar amplitude (~100 kG), results for differentially rotating and uniformly rotating tachoclines are almost the same. In contrast, the unmagnetized differentially rotating tachocline would always be weakly oblate. We propose that a strong toroidal field in the overshoot part of the tachocline should tend to suppress the overshooting, thereby increasing the magnetic storage capacity of the layer since the stratification there should become more subadiabatic. We illustrate the effect of this process on the shape and thickness of the layer by assuming its effective gravity is a function of field strength. If toroidal fields are concentrated in relatively narrow bands which migrate toward the equator with the advance of the sunspot cycle, then they should be accompanied by a ``thickness front'' advancing at the same rate. Applying our model to the prolateness estimate of Charbonneau et al. yields toroidal fields of 60-150 kG in the overshoot layer, consistent with other considerations. Their prolateness in the radiative part of the tachocline would require ~600 kG fields to be present.

  15. Partial oxidation power plant with reheating and method thereof

    DOEpatents

    Newby, Richard A.; Yang, Wen-Ching; Bannister, Ronald L.

    1999-01-01

    A system and method for generating power having an air compression/partial oxidation system, a turbine, and a primary combustion system. The air compression/partial oxidation system receives a first air stream and a fuel stream and produces a first partially oxidized fuel stream and a first compressed air stream therefrom. The turbine expands the first partially oxidized fuel stream while being cooled by the first compressed air stream to produce a heated air stream. The heated air stream is injected into the expanding first partially oxidized fuel stream, thereby reheating it in the turbine. A second partially oxidized fuel stream is emitted from the turbine. The primary combustion system receives said second partially oxidized fuel stream and a second air stream, combusts said second partially oxidized fuel stream, and produces rotating shaft power and an emission stream therefrom.

  16. Numerical simulation of VAWT on the effects of rotation cylinder

    NASA Astrophysics Data System (ADS)

    Xing, Shuda; Cao, Yang; Ren, Fuji

    2017-06-01

    Based on Finite Element Analysis Method, studying on Vertical Axis Wind Turbine (VAWT) which is added rotating cylinder in front of its air foils, especially focusing on the analysis of NACA6 series air foils about variation of lift to drag ratio. Choosing the most suitable blades with rotary cylinder added on leading edge. Analysis indicates that the front rotating cylinders on the VAWT is benefit to lift rise and drag fall. The most suitable air foil whose design lift coefficient is 0.8, the blades relative thickness is 20%, and the optimistic tip speed ratio is about 7.

  17. Drop deformation and breakup in a partially filled horizontal rotating cylinder

    NASA Astrophysics Data System (ADS)

    White, Andrew; Pereira, Caroline; Hyacinthe, Hyaquino; Ward, Thomas

    2014-11-01

    Drop deformation and breakup due to shear flow has been studied extensively in Couette devices as well as in gravity-driven flows. In these cases shear is generated either by the moving wall or the drop's motion. For such flows the drop shape remains unperturbed at low capillary number (Ca), deforms at moderate Ca , and can experience breakup as Ca --> 1 and larger. Here single drops of NaOH(aq) will be placed in a horizontal cylindrical rotating tank partially filled with vegetable oil resulting in 10-2 < Ca <101 . It will be shown that the reactive vegetable oil-NaOH(aq) system, where surfactants are produced in situ by saponification, can yield lower minimum surface tensions and faster adsorption than non-reactive surfactant systems. Oil films between the wall and drop as well as drop shape will be observed as rotation rates and NaOH(aq) concentration are varied. Results will be presented in the context of previous work on bubble and drop shapes and breakup. NSF CBET #1262718.

  18. Regimes of an atmospheric pressure nanosecond repetitively pulsed discharge for methane partial oxidation

    NASA Astrophysics Data System (ADS)

    Maqueo, P. D. G.; Maier, M.; Evans, M. D. G.; Coulombe, S.; Bergthorson, J. M.

    2018-04-01

    The operation of a nanosecond repetitively pulsed discharge for partial oxidation of CH4 is characterized at atmospheric pressure and room temperature. Two regimes are observed: diffuse and filamentary. The first is a low power regime, characterized by low rotational temperatures around 400 K. The second is much more energetic with rotational temperatures close to 600 K. Both have vibrational temperatures of at least 10 times their rotational temperatures. The average electron number density was determined to be 8.9×1015 and 4.0×1017 cm-3, respectively, showing an increase in the ionization fraction in the more powerful filamentary regime. Results of CH4 conversion to H2, CO, CO2 and C2H6 are presented for the filamentary regime, while the diffuse regime shows no measurable conversion ability. As expected, oxidative mixtures show higher conversion ability than pure CH4. A maximum conversion efficiency of 26.3% and a maximum energy efficiency of 19.7% were reached for the oxidative mixtures.

  19. Classification and Surgical Repair of Ramp Lesions of the Medial Meniscus.

    PubMed

    Thaunat, Mathieu; Fayard, Jean Marie; Guimaraes, Tales M; Jan, Nicolas; Murphy, Colin G; Sonnery-Cottet, Bertrand

    2016-08-01

    Ramp lesions of the medial meniscus are commonly associated with anterior cruciate ligament ruptures and consist of longitudinal peripheral tears of the posterior horn of the medial meniscus. Given the frequency of partial-thickness tears, they can be difficult to diagnose arthroscopically from the anterior compartment. We describe a classification of the different types of ramp lesions depending on both tear pattern (partial- or full-thickness tear) and associated meniscotibial ligament disruption. An original technique of arthroscopic suture placement through a single posteromedial portal with a 25° curved suture hook device is described.

  20. The role of silver in the processing and properties of Bi-2212

    NASA Technical Reports Server (NTRS)

    Lang, TH.; Heeb, B.; Buhl, D.; Gauckler, L. J.

    1995-01-01

    The influence of the silver content and the oxygen partial pressure on the solidus temperature and the weight loss during melting of Bi2Sr2Ca1Cu2O(x) has been examined by means of DTA and TGA. By decreasing the oxygen partial pressure the solidus is lowered (e.g. del T = 59 C by decreasing pO2 from 1 atm to 0.001 atm) and the weight loss is increased. The addition of silver causes two effects: (1) the solidus is further decreased (e.g. 2 wt% Ag lower T (solidus) by up to 25 C, depending on the oxygen partial pressure); and (2) the weight loss during melting is reduced. Thick films (10-20 micron in thickness) with 0 and 5 wt% silver and bulk samples with) and 2.7 wt% silver were melt processed in flowing oxygen on a silver substrate in the DTA, allowing the observation of the melting process and a good temperature control. The critical current densities are vigorously dependent on the maximum processing temperature. The highest j(sub c) in thick films (8000 A/sq cm at 77 K, O T) was reached by melting 7 C above the solidus temperature. The silver addition shows no significant effect on the processing parameters or the superconducting properties. The highest j(sub c) for bulk samples (1 mm in thickness) was obtained by partial melting at 900 C or 880 C, depending on the silver content of the powder (0 or 2.7 wt%). The j(sub c) of the samples is slightly enhanced from 1800 A/sq cm (at 77 K, O T) to 2000 A/sq cm by the silver addition. To be able to reach at least 80% of the maximum critical current density, the temperature has to be controlled in a window of 5 C for thick films and 17 C for bulk samples.

  1. Rotating disk electrodes to assess river biofilm thickness and elasticity.

    PubMed

    Boulêtreau, Stéphanie; Charcosset, Jean-Yves; Gamby, Jean; Lyautey, Emilie; Mastrorillo, Sylvain; Azémar, Frédéric; Moulin, Frédéric; Tribollet, Bernard; Garabetian, Frédéric

    2011-01-01

    The present study examined the relevance of an electrochemical method based on a rotating disk electrode (RDE) to assess river biofilm thickness and elasticity. An in situ colonisation experiment in the River Garonne (France) in August 2009 sought to obtain natural river biofilms exhibiting differentiated architecture. A constricted pipe providing two contrasted flow conditions (about 0.1 and 0.45 m s(-1) in inflow and constricted sections respectively) and containing 24 RDE was immersed in the river for 21 days. Biofilm thickness and elasticity were quantified using an electrochemical assay on 7 and 21 days old RDE-grown biofilms (t(7) and t(21), respectively). Biofilm thickness was affected by colonisation length and flow conditions and ranged from 36 ± 15 μm (mean ± standard deviation, n = 6) in the fast flow section at t(7) to 340 ± 140 μm (n = 3) in the slow flow section at t(21). Comparing the electrochemical signal to stereomicroscopic estimates of biofilms thickness indicated that the method consistently allowed (i) to detect early biofilm colonisation in the river and (ii) to measure biofilm thickness of up to a few hundred μm. Biofilm elasticity, i.e. biofilm squeeze by hydrodynamic constraint, was significantly higher in the slow (1300 ± 480 μm rpm(1/2), n = 8) than in the fast flow sections (790 ± 350 μm rpm(1/2), n = 11). Diatom and bacterial density, and biofilm-covered RDE surface analyses (i) confirmed that microbial accrual resulted in biofilm formation on the RDE surface, and (ii) indicated that thickness and elasticity represent useful integrative parameters of biofilm architecture that could be measured on natural river assemblages using the proposed electrochemical method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Comparison of Clinical and Radiological Results in the Arthroscopic Repair of Full-Thickness Rotator Cuff Tears With and Without the Anterior Attachment of the Rotator Cable.

    PubMed

    Cho, Nam Su; Moon, Seong Cheol; Hong, Se Jung; Bae, Seong Hae; Rhee, Yong Girl

    2017-09-01

    The anterior rotator cable is critical in force transmission of the rotator cuff. However, few clinical studies have examined the correlation between the integrity of the anterior supraspinatus tendon and surgical outcomes in patients with rotator cuff tears. To compare the clinical and structural outcomes of the arthroscopic repair of full-thickness rotator cuff tears with and without anterior disruption of the supraspinatus tendon. Cohort study; Level of evidence, 3. One hundred eighty-one shoulders available for magnetic resonance imaging (MRI) at least 6 months after arthroscopic rotator cuff repair, with a minimum 1-year follow-up, were enrolled. The anterior attachment of the rotator cable was disrupted in 113 shoulders (group A) and intact in 68 shoulders (group B). The mean age at the time of surgery in groups A and B was 59.6 and 59.2 years, respectively, and the mean follow-up period was 24.2 and 25.1 months, respectively. There were statistically significant differences in the preoperative tear size and pattern and muscle fatty degeneration between the 2 groups ( P = .004, P = .008, and P < .001, respectively). At final follow-up, the mean visual analog scale (VAS) for pain score during motion was 1.31 ± 0.98 and 1.24 ± 0.90 in groups A and B, respectively ( P = .587). The mean Constant score was 77.5 ± 11.2 and 78.0 ± 11.9 points in groups A and B, respectively ( P = .875). The mean University of California, Los Angeles score was 30.5 ± 4.1 and 31.0 ± 3.0 points in groups A and B, respectively ( P = .652). In assessing the repair integrity on postoperative MRI, the retear rate was 23.9% and 14.7% in groups A and B, respectively ( P = .029). Irrespective of involvement in the anterior attachment of the rotator cable, the mean 24-month follow-up demonstrated excellent pain relief and improvement in the ability to perform activities of daily living after arthroscopic rotator cuff repair. However, tears with anterior disruption of the rotator cable showed a significantly larger and more complex tear pattern and more advanced fatty degeneration. Additionally, the retear rate was significantly higher in patients with a tear involving the anterior attachment of the rotator cable.

  3. Electrohydrodynamics of drops covered with small particles

    NASA Astrophysics Data System (ADS)

    Ouriemi, Malika; Vlahovska, Petia

    2013-11-01

    A weakly conductive drop immersed in a more conductive liquid first undergoes an oblate deformation, and then experiences a rotation similar to Quincke rotation when submitted to an increasing DC uniform electrical field. We present an experimental study of a drop with an interface partially or completely covered with microscopic particles. Depending on the field intensity, the surface coverage, and the characteristics of the particles, the drop exhibits: (i) prolate deformation, (ii) emergence of pattern of sustained particle motions, or (iii) decrease of the electrical field that induces rotation.

  4. Missing mass or missing light?

    NASA Astrophysics Data System (ADS)

    Davies, J. I.

    1990-07-01

    Disney et al. (1989) have argued that the observational data are consistent with disk galaxies being optically thick, particularly in their inner regions. Here, these results are used to reinterpret the radial surface-brightness distributions of spiral galaxies. It is found that the fitting of a profile with an absorbed disk plus bulge leads to both disk and bulge masses (mass in luminous material) that are larger than previously assumed. In addition, it is shown how the rotation velocity, as determined from optical data in the central regions, may systematically underestimate the true rotational velocity in an optically thick disk. If the bulges of late-type galaxies are as large as is hypothesized, then this has important implications in models of galaxy evolution and galaxy dynamics. The model greatly reduces or even eliminates the need for dark matter within the optical radius; it removes a major argument against S0 evolution from later-type galaxies; it accounts for the similarity of rotation curve forms among galaxies of different morphological types; and it leads to a further reappraisal of the observed constancy of the extrapolated central surface brightness of galactic disks.

  5. The effects of rotational flow, viscosity, thickness, and shape on transonic flutter dip phenomena

    NASA Technical Reports Server (NTRS)

    Reddy, T. S. R.; Srivastava, Rakesh; Kaza, Krishna Rao V.

    1988-01-01

    The transonic flutter dip phenomena on thin airfoils, which are employed for propfan blades, is investigated using an integrated Euler/Navier-Stokes code and a two degrees of freedom typical section structural model. As a part of the code validation, the flutter characteristics of the NACA 64A010 airfoil are also investigated. In addition, the effects of artificial dissipation models, rotational flow, initial conditions, mean angle of attack, viscosity, airfoil thickness and shape on flutter are investigated. The results obtained with a Euler code for the NACA 64A010 airfoil are in reasonable agreement with published results obtained by using transonic small disturbance and Euler codes. The two artificial dissipation models, one based on the local pressure gradient scaled by a common factor and the other based on the local pressure gradient scaled by a spectral radius, predicted the same flutter speeds except in the recovery region for the case studied. The effects of rotational flow, initial conditions, mean angle of attack, and viscosity for the Reynold's number studied seem to be negligible or small on the minima of the flutter dip.

  6. Modern Optimization Methods in Minimum Weight Design of Elastic Annular Rotating Disk with Variable Thickness

    NASA Astrophysics Data System (ADS)

    Jafari, S.; Hojjati, M. H.

    2011-12-01

    Rotating disks work mostly at high angular velocity and this results a large centrifugal force and consequently induce large stresses and deformations. Minimizing weight of such disks yields to benefits such as low dead weights and lower costs. This paper aims at finding an optimal disk thickness profile for minimum weight design using the simulated annealing (SA) and particle swarm optimization (PSO) as two modern optimization techniques. In using semi-analytical the radial domain of the disk is divided into some virtual sub-domains as rings where the weight of each rings must be minimized. Inequality constrain equation used in optimization is to make sure that maximum von Mises stress is always less than yielding strength of the material of the disk and rotating disk does not fail. The results show that the minimum weight obtained for all two methods is almost identical. The PSO method gives a profile with slightly less weight (6.9% less than SA) while the implementation of both PSO and SA methods are easy and provide more flexibility compared with classical methods.

  7. Gamma-ray bursts from stellar mass accretion disks around black holes

    NASA Technical Reports Server (NTRS)

    Woosley, S. E.

    1993-01-01

    A cosmological model for gamma-ray bursts is explored in which the radiation is produced as a broadly beamed pair fireball along the rotation axis of an accreting black hole. The black hole may be a consequence of neutron star merger or neutron star-black hole merger, but for long complex bursts, it is more likely to come from the collapse of a single Wolf-Rayet star endowed with rotation ('failed' Type Ib supernova). The disk is geometrically thick and typically has a mass inside 100 km of several tenths of a solar mass. In the failed supernova case, the disk is fed for a longer period of time by the collapsing star. At its inner edge the disk is thick to its own neutrino emission and evolves on a viscous time scale of several seconds. In a region roughly 30 km across, interior to the accretion disk and along its axis of rotation, a pair fireball is generated by neutrino annihilation and electron-neutrino scattering which deposit approximately 10 exp 50 ergs/s.

  8. Demystifying the Clinical Diagnosis of Greater Trochanteric Pain Syndrome in Women.

    PubMed

    Ganderton, Charlotte; Semciw, Adam; Cook, Jill; Pizzari, Tania

    2017-06-01

    To evaluate the diagnostic accuracy of 10 clinical tests that can be used in the diagnosis of greater trochanteric pain syndrome (GTPS) in women, and to compare these clinical tests to magnetic resonance imaging (MRI) findings. Twenty-eight participants with GTPS (49.5 ± 22.0 years) and 18 asymptomatic participants (mean age ± standard deviation [SD], 52.5 ± 22.8 years) were included. A blinded physiotherapist performed 10 pain provocation tests potentially diagnostic for GTPS-palpation of the greater trochanter, resisted external derotation test, modified resisted external derotation test, standard and modified Ober's tests, Patrick's or FABER test, resisted hip abduction, single-leg stance test, and the resisted hip internal rotation test. A sample of 16 symptomatic and 17 asymptomatic women undertook a hip MRI scan. Gluteal tendons were evaluated and categorized as no pathology, mild tendinosis, moderate tendinosis/partial tear, or full-thickness tear. Clinical test analyses show high specificity, high positive predictive value, low to moderate sensitivity, and negative predictive value for most clinical tests. All symptomatic and 88% of asymptomatic participants had pathological gluteal tendon changes on MRI, from mild tendinosis to full-thickness tear. The study found the Patrick's or FABER test, palpation of the greater trochanter, resisted hip abduction, and the resisted external derotation test to have the highest diagnostic test accuracy for GTPS. Tendon pathology on MRI is seen in both symptomatic and asymptomatic women.

  9. Predictive factor analysis for successful performance of iris recognition-assisted dynamic rotational eye tracking during laser in situ keratomileusis.

    PubMed

    Prakash, Gaurav; Ashok Kumar, Dhivya; Agarwal, Amar; Jacob, Soosan; Sarvanan, Yoga; Agarwal, Athiya

    2010-02-01

    To analyze the predictive factors associated with success of iris recognition and dynamic rotational eye tracking on a laser in situ keratomileusis (LASIK) platform with active assessment and correction of intraoperative cyclotorsion. Interventional case series. Two hundred seventy-five eyes of 142 consecutive candidates underwent LASIK with attempted iris recognition and dynamic rotational tracking on the Technolas 217z100 platform (Techolas Perfect Vision, St Louis, Missouri, USA) at a tertiary care ophthalmic hospital. The main outcome measures were age, gender, flap creation method (femtosecond, microkeratome, epi-LASIK), success of static rotational tracking, ablation algorithm, pulses, and depth; preablation and intraablation rotational activity were analyzed and evaluated using regression models. Preablation static iris recognition was successful in 247 eyes, without difference in flap creation methods (P = .6). Age (partial correlation, -0.16; P = .014), amount of pulses (partial correlation, 0.39; P = 1.6 x 10(-8)), and gender (P = .02) were significant predictive factors for the amount of intraoperative cyclodeviation. Tracking difficulties leading to linking the ablation with a new intraoperatively acquired iris image were more with femtosecond-assisted flaps (P = 2.8 x 10(-7)) and the amount of intraoperative cyclotorsion (P = .02). However, the number of cases having nonresolvable failure of intraoperative rotational tracking was similar in the 3 flap creation methods (P = .22). Intraoperative cyclotorsional activity depends on the age, gender, and duration of ablation (pulses delivered). Femtosecond flaps do not seem to have a disadvantage over microkeratome flaps as far as iris recognition and success of intraoperative dynamic rotational tracking is concerned. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  10. Distribution, Complications, and Outcome of Footpad Injuries in Pet and Military Working Dogs.

    PubMed

    Hansen, Lane A; Hazenfield, Kurt M; Olea-Popelka, Francisco; Smeak, Dan D

    2015-01-01

    This study reports the findings of 120 traumatic pad injuries in pet and military dogs. Most dogs (68%) presented with a laceration to a thoracic limb footpad, and one-third of dogs were middle-aged castrated males. Metacarpal pads were most commonly injured. Short-term complications were noted in 27% of dogs. No long-term complications were identified. No disability from pad injury was present at the completion of healing. Concurrent injuries to adjacent structures were uncommon and did not affect outcome. Dogs with full-thickness pad lacerations were at greater risk for major short-term complications compared to dogs with partial-thickness pad lacerations (odds ratio, 7.27; P = .001). Military working dogs with full-thickness pad lacerations were at greater risk for major short-term complications than pet dogs with a similar injury. When major complications developed in dogs with full-thickness pad injuries, time to final healing was significantly longer (by a median of 12 days). The partial-thickness pad lesions healed uneventfully regardless of whether they were bandaged, surgically repaired, or left to heal by second intention. Suture repair and bandaging of full-thickness lesions could not be shown to either decrease the risk for complications or improve healing. Future work should focus on establishing standards for footpad treatment to reduce complications.

  11. Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karunamuni, Roshan; Bartsch, Hauke; White, Nathan S.

    Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thicknessmore » between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.« less

  12. Role of epidermal stem cells in repair of partial-thickness burn injury after using Moist Exposed Burn Ointment (MEBO(®)) histological and immunohistochemical study.

    PubMed

    El-Hadidy, M R; El-Hadidy, A R; Bhaa, A; Asker, S A; Mazroa, S A

    2014-04-01

    Moist Exposed Burn Ointment (MEBO(®)) is widely used topical agent applied on skin burn. This study investigated the effect of MEBO topical application on activation and proliferation of epidermal stem cells through the immunohistochemical localization of cytokeratin 19 (CK19) as a known marker expressed in epidermal stem cells. Biopsies from normal skin and burn wounds were taken from 21 patients with partial thickness burn 1, 4, 7, 14, 21, and 28 days after treatment with MEBO. Tissue sections were prepared for histological study and for CK19 immunohistochemical localization. In control skin, only few cells showed a positive CK19 immune-reaction. Burned skin showed necrosis of full thickness epidermis that extended to dermis. Gradual regeneration of skin accompanied with an enhancement in CK19 immune-reactivity was noted 4, 7, 14 and 21 days after treatment with MEBO. On day 28, a complete regeneration of skin was observed with a return of CK19 immune-reactivity to the basal pattern again. In conclusion, the enhancement of epidermal stem cell marker CK19 after treatment of partial thickness burn injuries with MEBO suggested the role of MEBO in promoting epidermal stem cell activation and proliferation during burn wound healing. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Asymptotic derivation of nonlocal plate models from three-dimensional stress gradient elasticity

    NASA Astrophysics Data System (ADS)

    Hache, F.; Challamel, N.; Elishakoff, I.

    2018-01-01

    This paper deals with the asymptotic derivation of thin and thick nonlocal plate models at different orders from three-dimensional stress gradient elasticity, through the power series expansions of the displacements in the thickness ratio of the plate. Three nonlocal asymptotic approaches are considered: a partial nonlocality following the thickness of the plate, a partial nonlocality following the two directions of the plates and a full nonlocality (following all the directions). The three asymptotic approaches lead at the zeroth order to a nonlocal Kirchhoff-Love plate model, but differ in the expression of the length scale. The nonlocal asymptotic models coincide at this order with the stress gradient Kirchhoff-Love plate model, only when the nonlocality is following the two directions of the plate and expressed through a nabla operator. This asymptotic model also yields the nonlocal truncated Uflyand-Mindlin plate model at the second order. However, the two other asymptotic models lead to equations that differ from the current existing nonlocal engineering models (stress gradient engineering plate models). The natural frequencies for an all-edges simply supported plate are obtained for each model. It shows that the models provide similar results for low orders of frequencies or small thickness ratio or nonlocal lengths. Moreover, only the asymptotic model with a partial nonlocality following the two directions of the plates is consistent with a stress gradient plate model, whatever the geometry of the plate.

  14. Three-year clinical follow-up of posterior teeth restored with leucite-reinforced ips empress onlays and partial veneer crowns.

    PubMed

    Murgueitio, Rafael; Bernal, Guillermo

    2012-07-01

    The aim of this study was to analyze the survival rate and failure mode of IPS leucite-reinforced ceramic onlays and partial veneer crowns regarding thickness under the following clinical conditions: vital versus nonvital teeth, tooth location, and type of opposing dentition. Teeth were prepared according to established guidelines for ceramic onlays and partial veneer crowns. Before cementation, the restorations were measured for occlusal thickness at the central fossa, mesial, and distal marginal ridges, and functional and nonfunctional cusps. A total of 210 ceramic restorations were cemented in 99 patients within a mean observation period of 2.9 ± 1.89 years. The mode of failure was classified and evaluated as (1) adhesive, (2) cohesive, (3) combined failure, (4) decementation, (5) tooth sensitivity, and (6) pulpal necrosis. Kaplan, log-rank, and Cox regression tests were used for statistical analysis. The failure rate was 3.33% (7/210). Increased material thickness produced less probability of failures. Vital teeth were less likely to fail than nonvital teeth. Second molars were five times more susceptible to failure than first molars. Tooth sensitivity postcementation and the type of opposing dentition were not statistically significant in this study. In this study, thickness of the restorations, tooth vitality, and location of teeth in the dental arch influenced restoration failures. © 2012 by the American College of Prosthodontists.

  15. Critical thickness of MBE-grown Ga 1-xIn xSb ( x<0.2) on GaSb

    NASA Astrophysics Data System (ADS)

    Nilsen, T. A.; Breivik, M.; Selvig, E.; Fimland, B. O.

    2009-03-01

    Several Ga 1-xIn xSb layers, capped with 1 μm of GaSb, were grown on GaSb(0 0 1) substrates by molecular beam epitaxy in a Varian Gen II Modular system using either the conventional sample growth position with substrate rotation, or a tilted sample position with no substrate rotation. The GaInSb layers were examined by X-ray diffraction (XRD) using both symmetrical and asymmetrical reflections. The "tilted sample method" gave a variation of ±25% in thickness of the Ga 1-xIn xSb layers, while the indium (In) content varied by ±10% around the nominal value. The disappearance of thickness fringes in 004 XRD scans was used to determine the onset of relaxation, as determining the in-plane lattice constant for tilted samples was found to be difficult. Determining residual strain in samples grown by the tilted method was likewise found to be very difficult. The critical thickness for several In mole fractions between 5% and 19% was determined and was found to be from 2.2 to 2.7 times higher than predicted by Matthews and Blakeslee (1974) [J. Crystal Growth 27 (1974) 118] but lower than that predicted by People and Bean (1985) [Appl. Phys. Lett. 47 (1985) 322].

  16. An analytical theory for a three-dimensional thick-disc thin-plate vibratory gyroscope

    NASA Astrophysics Data System (ADS)

    Sedebo, G. T.; Joubert, S. V.; Shatalov, M. Y.

    2018-04-01

    We consider a cylindrical vibratory gyroscope comprising a not necessarliy thin-shelled annular disc with small-plate thickness, vibrating in the m -th vibration mode in-plane and in the (m + 1)st vibration mode out-of-plane. We derive the equations of motion for this contrivance in the “force-to-rebalance regime” and show how a slow (three-dimensional) inertial rotation rate of the gyroscope can be calculated in terms of amplitudes of vibration and other constants, all of which can be measured experimentally or calculated when the eigenfunctions and eigenvalues of the system are known. By means of a concrete example, a numerical experiment demonstrates how varying the inner radius of the annulus as well as the thickness of the plate allows us to “tune” the vibration frequencies of the in-plane and out-of-plane vibrations so that they coincide (for all practical purposes), eliminating any frequency split. Conventionally, an array of at least three thin-shelled hemispherical (or thin-ring) vibratory (resonator) gyroscopes is used to measure any three-dimensional rotation of the craft to which the gyroscopes are fixed. With the design proposed here, the array can be reduced to a solitary, tuned, annular thick-disc thin-plate vibratory gyroscope, reducing both size and cost.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levy, Miguel; Chakravarty, A.; Huang, H.-C.

    Significant departures from bulk-like magneto-optic behavior are found in ultra-thin bismuth-substituted iron-garnet films grown by liquid-phase-epitaxy. These changes are due, at least in part, to geometrical factors and not to departures from bulk-composition in the transient layer at the film-substrate interface. A monotonic increase in specific Faraday rotation with reduced thickness is the signature feature of the observed phenomena. These are traced to size-dependent modifications in the diamagnetic transition processes responsible for the Faraday rotation. These processes correspond to the electronic transitions from singlet {sup 6}S ground states to spin-orbit split excited states of the Fe{sup 3+} ions in themore » garnet. A measurable reduction in the corresponding ferrimagnetic resonance linewidths is found, thus pointing to an increase in electronic relaxation times and longer lived excitations at reduced thicknesses. These changes together with a shift in vibrational frequency of the Bi-O bonds in the garnet at reduced thicknesses result in greatly enhanced magneto-optical performance. These studies were conducted on epitaxial monocrystalline Bi{sub 0.8}Gd{sub 0.2}Lu{sub 2}Fe{sub 5}O{sub 12} films.« less

  18. Clostridial collagenase aggravates the systemic inflammatory response in rats with partial-thickness burns.

    PubMed

    Dokumcu, Zafer; Ergun, Orkan; Celik, Handan Ak; Aydemir, Sohret; Sezak, Murat; Ozok, Geylani; Celik, Ahmet

    2008-11-01

    Clostridial collagenase A (CCA) has been shown effective in degrading collagen in eschar tissue and promoting healing in partial-thickness burns. As there are also reports of fever, leukocytosis, increased C-reactive protein (CRP) levels and septic complications during treatment with CCA, we aimed to determine in rats whether CCA aggravates the systemic inflammatory response. Rats with partial-thickness burns were randomly divided into groups with either no dressing (ND), povidone-iodine dressing (PID) or CCA dressing (CCAD). Body weights and temperatures, blood leukocyte counts, and serum levels of CRP, interleukin-1 beta (IL-1 beta), interleukin-6 (IL-6) and tumour necrosis factor-alpha (TNF-alpha), were measured at 0, 3, and 24h and days 3 and 7 from burn. Wounds were cultured on days 1, 3 and 7 and burn depth was evaluated on day 1. Body weights for all groups were significantly lower after burn, with highest loss (25.5%) in the CCAD group. At 3h a significant drop in rectal temperature was noted in all groups. The CCAD group had higher rectal temperature levels than the PID group on days 3 and 7 (p<0.05). Changes in serum levels of CRP, IL-1 beta, IL-6 and TNF-alpha were not significant in the ND and PID groups; the CCAD group showed a significant rise in serum levels of CRP on day 1, of IL-6 on day 3 and of TNF-alpha on day 7. Wound infection was more common in CCAD group and increased on days 3 and 7, but this was insignificant. CCA aggravated the systemic inflammatory response in rats with partial-thickness burns, which is accompanied by a higher risk of infection.

  19. Effect of wellbore storage and finite thickness skin on flow to a partially penetrating well in a phreatic aquifer

    NASA Astrophysics Data System (ADS)

    Pasandi, M.; Samani, N.; Barry, D. A.

    2008-02-01

    An analytical model is presented for the analysis of constant flux tests conducted in a phreatic aquifer having a partially penetrating well with a finite thickness skin. The solution is derived in the Laplace transform domain for the drawdown in the pumping well, skin and formation regions. The time-domain solution in terms of the aquifer drawdown is then obtained from the numerical inversion of the Laplace transform and presented as dimensionless drawdown-time curves. The derived solution is used to investigate the effects of the hydraulic conductivity contrast between the skin and formation, in addition to wellbore storage, skin thickness, delayed yield, partial penetration and distance to the observation well. The results of the developed solution were compared with those from an existing solution for the case of an infinitesimally thin skin. The latter solution can never approximate that for the developed finite skin. Dimensionless drawdown-time curves were compared with the other published results for a confined aquifer. Positive skin effects are reflected in the early time and disappear in the intermediate and late time aquifer responses. But in the case of negative skin this is reversed and the negative skin also tends to disguise the wellbore storage effect. A thick negative skin lowers the overall drawdown in the aquifer and leads to more persistent delayed drainage. Partial penetration increases the drawdown in the case of a positive skin; however its effect is masked by the negative skin. The influence of a negative skin is pronounced over a broad range of radial distances. At distant observation points the influence of a positive skin is too small to be reflected in early and intermediate time pumping test data and consequently the type curve takes its asymptotic form.

  20. Impact of a Newly Implemented Burn Protocol on Surgically Managed Partial Thickness Burns at a Specialized Burns Center in Singapore.

    PubMed

    Tay, Khwee-Soon Vincent; Chong, Si-Jack; Tan, Bien-Keem

    2016-03-01

    This study evaluated the impact of a newly implemented protocol for superficial to mid-dermal partial thickness burns which involves early surgery and rapid coverage with biosynthetic dressing in a specialized national burns center in Singapore. Consecutive patients with 5% or greater total body surface area (TBSA) superficial to mid-dermal partial thickness burns injury admitted to the Burns Centre at the Singapore General Hospital between August and December 2014 for surgery within 48 hours of injury were prospectively recruited into the study to form the protocol group. Comparable historical cases from the year 2013 retrieved from the burns center audit database were used to form the historical control group. Demographics (age, sex), type and depth of burns, %TBSA burnt, number of operative sessions, and length of stay were recorded for each patient of both cohorts. Thirty-nine burns patients managed under the new protocol were compared with historical control (n = 39) comparable in age and extensiveness of burns. A significantly shorter length of stay (P < 0.05) per TBSA burns was observed in the new protocol group (0.74 day/%TBSA) versus historical control (1.55 day/%TBSA). Fewer operative sessions were needed under the new protocol for burns 10% or greater TBSA burns (P < 0.05). The authors report their promising experience with a newly implemented protocol for surgically managed burns patients which involves early surgery and appropriate use of biosynthetic dressing on superficial to mid-dermal partial thickness burns. Clinically, shorter lengths of stay, fewer operative sessions, and decreased need for skin grafting of burns patient were observed.

  1. A phase II prospective, non-comparative assessment of a new silver sodium carboxymethylcellulose (AQUACEL(®) Ag BURN) glove in the management of partial thickness hand burns.

    PubMed

    Duteille, Franck; Jeffery, Steven L A

    2012-11-01

    Nylon-reinforced silver sodium carboxymethylcellulose (AQUACEL(®) Ag BURN) dressings were developed to be pliable and conforming for the management of partial-thickness burns. This study evaluated the AQUACEL(®) Ag BURN glove for the management of hand burns. This 21-day, phase II, prospective, non-comparative study included 23 patients with partial-thickness hand burn of at least two fingers. The AQUACEL(®) Ag BURN glove was applied to one hand and could remain in place up to 21 days until clinically indicated to change the glove. Dressings were evaluated 1, 2, 4, 6, 8, 14, and 21 days after initial application. Safety was the primary study endpoint. Sixteen (70%) hand burns re-epithelialized fully over a mean of 15.6 days. Initial application was easy/very easy for 20 (87%) patients. Mean time for initial dressing application was 5.4 min. At final evaluation, most patients gave ratings of excellent/good for conformability (91%), overall glove performance (74%), and appropriateness of sizes (83%). Mean pain score from 0 (none) to 10 (worst imaginable) was 3.43 at baseline; during the study, mean scores were 1.15 at rest and 2.29 during movement. Of 61 glove removals, most (72%) were easy/very easy, and 12% had fallen off. Adverse events (wound site or elsewhere) occurred in 15 (65%) patients. Treatment-related adverse events were wound pain (17%), maceration (9%), and stiff fingers (4%). The AQUACEL(®) Ag BURN glove was well tolerated in the management of partial-thickness hand burn. Many patients used only one glove. When glove changes were required, they were usually quick and easy. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  2. SU-E-T-564: Multi-Helix Rotating Shield Brachytherapy for Cervical Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dadkhah, H; Wu, X; Flynn, R

    Purpose: To present a novel and practical brachytherapy technique, called multi-helix rotating shield brachytherapy (H-RSBT), for the precise positioning of a partial shield in a curved applicator. H-RSBT enables RSBT delivery using only translational motion of the radiation source/shield combination. H-RSBT overcomes the challenges associated with previously proposed RSBT approaches based on a serial (S-RSBT) step-and-shoot delivery technique, which required independent translational and rotational motion. Methods: A Fletcher-type applicator, compatible with the combination of a Xoft Axxent™ electronic brachytherapy source and a 0.5 mm thick tungsten shield, is proposed. The wall of the applicator contains six evenly-spaced helical keyways thatmore » rigidly define the emission direction of the shield as a function of depth. The shield contains three protruding keys and is attached to the source such that it rotates freely. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients representative of a wide range of high-risk clinical target volume (HR-CTV) shapes and applicator positions. The number of beamlets used in the treatment planning process was nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. For all the treatment plans the EQD2 of the HR-CTV was escalated until the EQD{sub 2cc} tolerance of either the bladder, rectum, or sigmoid colon was reached. Results: Treatment times for H-RSBT tended to be shorter than for S-RSBT, with changes of −38.47% to 1.12% with an average of −8.34%. The HR-CTV D{sub 90} changed by −8.81% to 2.08% with an average of −2.46%. Conclusion: H-RSBT is a mechanically feasible technique in the curved applicators needed for cervical cancer brachytherapy. S-RSBT and H-RSBT dose distributions were clinically equivalent for all patients considered, with the H-RSBT deliveries tending to be faster. Ryan Flynn has ownership interest in pxAlpha, LLC, which is a startup company developing a rotating shield brachytherapy system.« less

  3. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results.

    PubMed

    Tudisco, Cosimo; Bisicchia, Salvatore; Savarese, Eugenio; Fiori, Roberto; Bartolucci, Dario A; Masala, Salvatore; Simonetti, Giovanni

    2013-01-27

    Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR) repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR) repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA), showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS), the Simple Shoulder Test (SST) scores, surgical time and implant expense. The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant expense, despite no difference in clinical outcomes. We think that leakage of the contrast medium is due to an incomplete tendon-to-bone sealing, which is not a re-tear. This phenomenon could have important medicolegal implications. Level of evidence III. Treatment study: Case-control study.

  4. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results

    PubMed Central

    2013-01-01

    Background Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR) repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR) repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA), showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. Methods The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS), the Simple Shoulder Test (SST) scores, surgical time and implant expense. Results The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. Conclusions To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant expense, despite no difference in clinical outcomes. We think that leakage of the contrast medium is due to an incomplete tendon-to-bone sealing, which is not a re-tear. This phenomenon could have important medicolegal implications. Level of evidence III. Treatment study: Case–control study. PMID:23351978

  5. Return to Sport After Rotator Cuff Tear Repair: A Systematic Review and Meta-analysis.

    PubMed

    Klouche, Shahnaz; Lefevre, Nicolas; Herman, Serge; Gerometta, Antoine; Bohu, Yoann

    2016-07-01

    One of the most frequent demands from athletes after rotator cuff tear repair is to return to sport, if possible at the same level of play. The main goal of this study was to determine the rate of return to sport after treatment of rotator cuff tears. Meta-analysis and systematic review. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were followed to perform this systematic review and meta-analysis of the results in the literature, as well as for the presentation of results. A search of the literature was performed on the electronic databases MEDLINE, Scopus, EMBASE, and the Cochrane Library. The quality of the included studies was evaluated according to the MINORS (Methodological Index for Nonrandomized Studies) checklist. Inclusion criteria were studies in English evaluating return to sport after treatment of traumatic, degenerative, partial or full-thickness rotator cuff tears in patients practicing a sport regularly, whatever the level, all ages and sports included. The main judgment criterion was the number of patients who returned to a sports activity after treatment of a rotator cuff tear. The criterion was analyzed in 2 ways: return to sport (yes/no) and the level of play (identical or higher/lower level). Twenty-five studies were reviewed, including 859 patients (683 athletes), all treated surgically after a mean follow-up of 3.4 years (range, 0.3-13.4 years). The level of sports was recorded in 23 studies or 635 (93%) athletes and included 286 competitive or professional athletes and 349 recreational athletes. The most commonly practiced sports were baseball (224 participants), tennis (104 participants), and golf (54 participants). The overall rate of return to sport was 84.7% (95% CI, 77.6%-89.8%), including 65.9% (95% CI, 54.9%-75.4%) at an equivalent level of play, after 4 to 17 months. Of the professional and competitive athletes, 49.9% (95% CI, 35.3-64.6%) returned to the same level of play. Most recreational athletes return to sports at the same level of play as before their injury, but only half of professional and competitive athletes return to an equivalent level of play. © 2015 The Author(s).

  6. Rifting by continental rotation, mantle flow and hotspot volcanism in the salt-depositing South Atlantic

    NASA Astrophysics Data System (ADS)

    Szatmari, P.

    2012-04-01

    Rabinowitz & LaBrecque (1979) proposed that Africa and South America separated between 130 Ma and 107 Ma by 11.1° rigid plate rotation about an Euler pole in NE Brazil. According to those authors, the two continents remained contiguous in the north as the wedge-shaped South Atlantic opened up between them and deposited salt mostly over oceanic crust. Subsequent seismic profiling and drilling showed that salt, restricted to north of the volcanic proto-Walvis Ridge, deposited over rift sediments and stretched-thinned continental crust. Increasingly accurate restorations by Nürnberg & Müller (1991), Aslanian et al. (2009), Torsvik et al. (2009), and Moulin et al. (2010) differentiated in both continents several rigid plates separated by active deformation zones. Still, tectonic analysis of the rifted margins indicates that the main Early Cretaceous event was the clockwise rotation of South America about an Euler pole in its northeast. Both rifting and volcanism, including the Paraná-Etendeka large igneous province, where most flood basalts erupted at 134.6 ± 0.6 Ma (Thiede & Vasconcelos, 2010), were controlled by distance and orientation of rift segments relative to that pole in NE Brazil. Rifting was active from latest Jurassic to early Albian time (Magnavita et al., 2011) over inherited late Proterozoic fold-thrust belts. By Aptian time a long, dry wedge-shaped basin formed north of the volcanic barrier of the proto-Walvis Ridge, widening southward to 700 km and subsiding deep below sea level in the Santos Basin. The basin was filled with oil-rich lacustrine limestone and marine salt, each more than 2 km thick, deposited in often desiccating shallow water over the partially hyperextended continental crust of the São Paulo Plateau (Zalán et al., 2010; Magnavita et al., 2011; Szatmari, 2011). Further south marine sediments deposited over oceanic crust. Surface subsidence of the long, deep sediment-starved rift wedge was shaped, prior to the deposition of the lacustrine limestones and marine evaporites, by South America's continental rotation and by hotspot activity; asthenosphere inflow was limited by the bordering two old continents.

  7. The Effect of Bioturbation on Relative Paleointenstiy Records

    NASA Astrophysics Data System (ADS)

    Egli, R.; Zhao, X.; Gilder, S. A.

    2015-12-01

    Bioturbation is one of the key factors affecting the acquisition of a natural remanent magnetization (NRM) in sediments featuring a top mixed layer. In this case, a rotational diffusion process controls the acquisition timing, which is described in terms of a lock-in function, and NRM intensity. In general terms, NRM acquisition by rotational diffusion is described by a Smoluchowski-Debye differential equation, which yields analytical solutions describing how an initially acquired depositional remanent magnetization (DRM) is progressively replaced by a post-depositional remanent magnetization (PDRM) [Egli and Mao, Geochem. Geophys. Geosyst. 16, 995-1016, 2015]. These solutions in turn support the calculation of lock-in functions. Results are controlled by the following parameters: (1) a rotation diffusivity constant γ = 2DrL/ω, where Dr is the rotational diffusion coefficient, L the thickness of the mixed layer, and ω the sedimentation rate, and (2) the ratio between magnetic aligning torques τm = mB and the torques τp associated with mechanical interactions between sediment particles and with the action of perturbing forces. The PDRM acquisition rate and the extent of DRM replacement is controlled by γ, while PDRM intensity is a Langevin function of τm/ τp. Associated lock-in functions range from a constant (NRM is acquired only at the sediment surface) to the classical lock-in function starting below the mixed layer, though intermediate situations where PDRM is partially acquired in the mixed layer. This model has been confirmed by redeposition experiments performed with fresh sediment containing living microorganisms. Redeposition experiments show that the intensity of bioturbation-driven PDRMs can reach ~50% of the originally acquired DRM. Our model has profound consequences for the evaluation of relative paleointensity records, where variations can be driven by changes of the depositional environment. While this knowledge is not new, we provide for the first time a key for understanding, in a quantitative manner, how the NRM acquisition efficiency is controlled by bioturbation. A combination of proxies leading to estimates of the bioturbation activity might provide a new path for improving the reliability of relative paleointensity records.

  8. Rotating flow of a nanofluid due to an exponentially stretching surface with suction

    NASA Astrophysics Data System (ADS)

    Salleh, Siti Nur Alwani; Bachok, Norfifah; Arifin, Norihan Md

    2017-08-01

    An analysis of the rotating nanofluid flow past an exponentially stretched surface with the presence of suction is studied in this work. Three different types of nanoparticles, namely, copper, titania and alumina are considered. The system of ordinary differential equations is computed numerically using a shooting method in Maple software after being transformed from the partial differential equations. This transformation has considered the similarity transformations in exponential form. The physical effect of the rotation, suction and nanoparticle volume fraction parameters on the rotating flow and heat transfer phenomena is investigated and has been described in detail through graphs. The dual solutions are found to appear when the governing parameters reach a certain range.

  9. Partial oxidation power plant with reheating and method thereof

    DOEpatents

    Newby, R.A.; Yang, W.C.; Bannister, R.L.

    1999-08-10

    A system and method are disclosed for generating power having an air compression/partial oxidation system, a turbine, and a primary combustion system. The air compression/partial oxidation system receives a first air stream and a fuel stream and produces a first partially oxidized fuel stream and a first compressed air stream therefrom. The turbine expands the first partially oxidized fuel stream while being cooled by the first compressed air stream to produce a heated air stream. The heated air stream is injected into the expanding first partially oxidized fuel stream, thereby reheating it in the turbine. A second partially oxidized fuel stream is emitted from the turbine. The primary combustion system receives said second partially oxidized fuel stream and a second air stream, combusts said second partially oxidized fuel stream, and produces rotating shaft power and an emission stream therefrom. 2 figs.

  10. Universal Faraday Rotation in HgTe Wells with Critical Thickness.

    PubMed

    Shuvaev, A; Dziom, V; Kvon, Z D; Mikhailov, N N; Pimenov, A

    2016-09-09

    The universal value of the Faraday rotation angle close to the fine structure constant (α≈1/137) is experimentally observed in thin HgTe quantum wells with a thickness on the border between trivial insulating and the topologically nontrivial Dirac phases. The quantized value of the Faraday angle remains robust in the broad range of magnetic fields and gate voltages. Dynamic Hall conductivity of the holelike carriers extracted from the analysis of the transmission data shows a theoretically predicted universal value of σ_{xy}=e^{2}/h, which is consistent with the doubly degenerate Dirac state. On shifting the Fermi level by the gate voltage, the effective sign of the charge carriers changes from positive (holes) to negative (electrons). The electronlike part of the dynamic response does not show quantum plateaus and is well described within the classical Drude model.

  11. Process Parameters Optimization in Single Point Incremental Forming

    NASA Astrophysics Data System (ADS)

    Gulati, Vishal; Aryal, Ashmin; Katyal, Puneet; Goswami, Amitesh

    2016-04-01

    This work aims to optimize the formability and surface roughness of parts formed by the single-point incremental forming process for an Aluminium-6063 alloy. The tests are based on Taguchi's L18 orthogonal array selected on the basis of DOF. The tests have been carried out on vertical machining center (DMC70V); using CAD/CAM software (SolidWorks V5/MasterCAM). Two levels of tool radius, three levels of sheet thickness, step size, tool rotational speed, feed rate and lubrication have been considered as the input process parameters. Wall angle and surface roughness have been considered process responses. The influential process parameters for the formability and surface roughness have been identified with the help of statistical tool (response table, main effect plot and ANOVA). The parameter that has the utmost influence on formability and surface roughness is lubrication. In the case of formability, lubrication followed by the tool rotational speed, feed rate, sheet thickness, step size and tool radius have the influence in descending order. Whereas in surface roughness, lubrication followed by feed rate, step size, tool radius, sheet thickness and tool rotational speed have the influence in descending order. The predicted optimal values for the wall angle and surface roughness are found to be 88.29° and 1.03225 µm. The confirmation experiments were conducted thrice and the value of wall angle and surface roughness were found to be 85.76° and 1.15 µm respectively.

  12. A simulation technique for predicting thickness of thermal sprayed coatings

    NASA Technical Reports Server (NTRS)

    Goedjen, John G.; Miller, Robert A.; Brindley, William J.; Leissler, George W.

    1995-01-01

    The complexity of many of the components being coated today using the thermal spray process makes the trial and error approach traditionally followed in depositing a uniform coating inadequate, thereby necessitating a more analytical approach to developing robotic trajectories. A two dimensional finite difference simulation model has been developed to predict the thickness of coatings deposited using the thermal spray process. The model couples robotic and component trajectories and thermal spraying parameters to predict coating thickness. Simulations and experimental verification were performed on a rotating disk to evaluate the predictive capabilities of the approach.

  13. Hip capsular thickness correlates with range of motion limitations in femoroacetabular impingement.

    PubMed

    Zhang, Kailai; de Sa, Darren; Yu, Hang; Choudur, Hema Nalini; Simunovic, Nicole; Ayeni, Olufemi Rolland

    2018-03-24

    Femoroacetabular impingement (FAI) is a clinical entity of the hip causing derangements in range of motion, pain, gait, and function. Computer-assisted modeling and clinical studies suggest that patients with FAI have increased capsular thickness compared to those without.A retrospective chart review was performed to assess relationships between capsular thickness, hip range of motion, and demographic factors in patients with FAI. Local Research Ethics Board approval was obtained to extract electronic medical records for 188 patients at a single institution who had undergone hip arthroscopy. Procedures were performed from 2009 to 2017 by a single, fellowship-trained, board-certified sports medicine orthopaedic surgeon. Inclusion criteria were preoperative hip range of motion testing, positive clinical impingement testing, and magnetic resonance imaging (MRI) of the affected hip. Patient demographics, hip range of motion, and time to surgery were recorded. MRIs were reviewed by a board-certified musculoskeletal radiologist blinded to clinical data. Maximum thickness of the anterior hip capsule was measured in axial, axial oblique, and sagittal oblique sequences. Anterior capsular thickness was also measured at the level of the femoral head-neck junction in axial sequences (axial midline). Axial midline capsular thickness was negatively correlated with hip flexion (r = - 0.196, p = 0.0042) and internal rotation (r = - 0.143, p = 0.0278). Significant differences were seen between genders in axial midline thickness (5.3 ± 1.4 mm males/4.8 ± 1.3 mm females, p = 0.0079), flexion (113° ± 18° males/120° ± 17° females, p = 0.0029), and internal rotation (23° ± 13° males/29° ± 12° females, p = 0.0155). Significant differences also existed between side affected in flexion (116° ± 17° right/119° ± 17° left, p = 0.0396) and internal rotation (26° ± 12° right/29° ± 13° left, p = 0.0029). Positive correlation was observed between axial oblique capsular thickness and flexion (r = 0.2345) (p = 0.0229). Increased anterior hip capsular thickness at the femoral head-neck correlates with limitations in hip range of motion in FAI. The strength of this relationship may be affected between pathologies, genders, and affected side. Pathologic thickening of the hip capsule may contribute to restricted hip mobility on clinical examination, and elucidation of this relationship may provide guidance into capsular management during hip arthroscopy. 4, retrospective case series.

  14. Partial melting of amphibolite to trondhjemite near Ykutat, Alaska

    NASA Technical Reports Server (NTRS)

    Barker, F.

    1986-01-01

    At Nunatak Fiord, 55 km NE of Yakutat, Alaska, a uniform layer of Cretaceous metabasalt approximately 3 km thick was metamorphosed to amphibolite facies and locally partially melted to trondhjemite pegmatite. Results of the rare earth element analysis performed on the amphibolite and the trondhjemite pegmatite are discussed.

  15. Simulations of turbulent rotating flows using a subfilter scale stress model derived from the partially integrated transport modeling method

    NASA Astrophysics Data System (ADS)

    Chaouat, Bruno

    2012-04-01

    The partially integrated transport modeling (PITM) method [B. Chaouat and R. Schiestel, "A new partially integrated transport model for subgrid-scale stresses and dissipation rate for turbulent developing flows," Phys. Fluids 17, 065106 (2005), 10.1063/1.1928607; R. Schiestel and A. Dejoan, "Towards a new partially integrated transport model for coarse grid and unsteady turbulent flow simulations," Theor. Comput. Fluid Dyn. 18, 443 (2005), 10.1007/s00162-004-0155-z; B. Chaouat and R. Schiestel, "From single-scale turbulence models to multiple-scale and subgridscale models by Fourier transform," Theor. Comput. Fluid Dyn. 21, 201 (2007), 10.1007/s00162-007-0044-3; B. Chaouat and R. Schiestel, "Progress in subgrid-scale transport modelling for continuous hybrid non-zonal RANS/LES simulations," Int. J. Heat Fluid Flow 30, 602 (2009), 10.1016/j.ijheatfluidflow.2009.02.021] viewed as a continuous approach for hybrid RANS/LES (Reynolds averaged Navier-Stoke equations/large eddy simulations) simulations with seamless coupling between RANS and LES regions is used to derive a subfilter scale stress model in the framework of second-moment closure applicable in a rotating frame of reference. This present subfilter scale model is based on the transport equations for the subfilter stresses and the dissipation rate and appears well appropriate for simulating unsteady flows on relatively coarse grids or flows with strong departure from spectral equilibrium because the cutoff wave number can be located almost anywhere inside the spectrum energy. According to the spectral theory developed in the wave number space [B. Chaouat and R. Schiestel, "From single-scale turbulence models to multiple-scale and subgrid-scale models by Fourier transform," Theor. Comput. Fluid Dyn. 21, 201 (2007), 10.1007/s00162-007-0044-3], the coefficients used in this model are no longer constants but they are some analytical functions of a dimensionless parameter controlling the spectral distribution of turbulence. The pressure-strain correlation term encompassed in this model is inspired from the nonlinear SSG model [C. G. Speziale, S. Sarkar, and T. B. Gatski, "Modelling the pressure-strain correlation of turbulence: an invariant dynamical systems approach," J. Fluid Mech. 227, 245 (1991), 10.1017/S0022112091000101] developed initially for homogeneous rotating flows in RANS methodology. It is modeled in system rotation using the principle of objectivity. Its modeling is especially extended in a low Reynolds number version for handling non-homogeneous wall flows. The present subfilter scale stress model is then used for simulating large scales of rotating turbulent flows on coarse and medium grids at moderate, medium, and high rotation rates. It is also applied to perform a simulation on a refined grid at the highest rotation rate. As a result, it is found that the PITM simulations reproduce fairly well the mean features of rotating channel flows allowing a drastic reduction of the computational cost in comparison with the one required for performing highly resolved LES. Overall, the mean velocities and turbulent stresses are found to be in good agreement with the data of highly resolved LES [E. Lamballais, O. Metais, and M. Lesieur, "Spectral-dynamic model for large-eddy simulations of turbulent rotating flow," Theor. Comput. Fluid Dyn. 12, 149 (1998)]. The anisotropy character of the flow resulting from the rotation effects is also well reproduced in accordance with the reference data. Moreover, the PITM2 simulations performed on the medium grid predict qualitatively well the three-dimensional flow structures as well as the longitudinal roll cells which appear in the anticyclonic wall-region of the rotating flows. As expected, the PITM3 simulation performed on the refined grid reverts to highly resolved LES. The present model based on a rational formulation appears to be an interesting candidate for tackling a large variety of engineering flows subjected to rotation.

  16. Predictors of outcomes after arthroscopic transosseous equivalent rotator cuff repair in 155 cases: a propensity score weighted analysis of knotted and knotless self-reinforcing repair techniques at a minimum of 2 years.

    PubMed

    Millett, Peter J; Espinoza, Chris; Horan, Marilee P; Ho, Charles P; Warth, Ryan J; Dornan, Grant J; Christoph Katthagen, J

    2017-10-01

    To evaluate the outcomes of two commonly used transosseous-equivalent (TOE) arthroscopic rotator cuff repair (RCR) techniques for full-thickness supraspinatus tendon tears (FTST) using a robust multi-predictor model. 155 shoulders in 151 patients (109 men, 42 women; mean age 59 ± 10 years) who underwent arthroscopic RCR of FTST, using either a knotted suture bridging (KSB) or a knotless tape bridging (KTB) TOE technique were included. ASES and SF-12 PCS scores assessed at a minimum of 2 years postoperatively were modeled using propensity score weighting in a multiple linear regression model. Patients able to return to the study center underwent a follow-up MRI for evaluation of rotator cuff integrity. The outcome data were available for 137 shoulders (88%; n = 35/41 KSB; n = 102/114 KTB). Seven patients (5.1%) that underwent revision rotator cuff surgery were considered failures. The median postoperative ASES score of the remaining 130 shoulders was 98 at a mean follow-up of 2.9 years (range 2.0-5.4 years). A higher preoperative baseline outcome score and a longer follow-up had a positive effect, whereas a previous RCR and workers' compensation claims (WCC) had a negative effect on final ASES or SF 12 PCS scores. The repair technique, age, gender and the number of anchors used for the RCR had no significant influence. Fifty-two patients returned for a follow-up MRI at a mean of 4.4 years postoperatively. Patients with a KSB RCR were significantly more likely to have an MRI-diagnosed full-thickness rotator cuff re-tear (p < 0.05). Excellent outcomes can be achieved at a minimum of 2 years following arthroscopic KSB or KTB TOE RCR of FTST. The preoperative baseline outcome score, a prior RCR, WCC and the length of follow-up significantly influenced the outcome scores. The repair technique did not affect the final functional outcomes, but patients with KTB TOE RCR were less likely to have a full-thickness rotator cuff re-tear. Level III, Retrospective Comparative Study.

  17. Methods and systems for monitoring a solid-liquid interface

    DOEpatents

    Stoddard, Nathan G.; Clark, Roger F.; Kary, Tim

    2010-07-20

    Methods and systems are provided for monitoring a solid-liquid interface, including providing a vessel configured to contain an at least partially melted material; detecting radiation reflected from a surface of a liquid portion of the at least partially melted material that is parallel with the liquid surface; measuring a disturbance on the surface; calculating at least one frequency associated with the disturbance; and determining a thickness of the liquid portion based on the at least one frequency, wherein the thickness is calculated based on.times. ##EQU00001## where g is the gravitational constant, w is the horizontal width of the liquid, and f is the at least one frequency.

  18. Crustal Structure of the Iceland Region from Spectrally Correlated Free-air and Terrain Gravity Data

    NASA Technical Reports Server (NTRS)

    Leftwich, T. E.; vonFrese, R. R. R. B.; Potts, L. V.; Roman, D. R.; Taylor, Patrick T.

    2003-01-01

    Seismic refraction studies have provided critical, but spatially restricted constraints on the structure of the Icelandic crust. To obtain a more comprehensive regional view of this tectonically complicated area, we spectrally correlated free-air gravity anomalies against computed gravity effects of the terrain for a crustal thickness model that also conforms to regional seismic and thermal constraints. Our regional crustal thickness estimates suggest thickened crust extends up to 500 km on either side of the Greenland-Scotland Ridge with the Iceland-Faeroe Ridge crust being less extended and on average 3-5 km thinner than the crust of the Greenland-Iceland Ridge. Crustal thickness estimates for Iceland range from 25-35 km in conformity with seismic predictions of a cooler, thicker crust. However, the deepening of our gravity-inferred Moho relative to seismic estimates at the thermal plume and rift zones of Iceland suggests partial melting. The amount of partial melting may range from about 8% beneath the rift zones to perhaps 20% above the plume core where mantle temperatures may be 200-400 C above normal. Beneath Iceland, areally limited regions of partial melting may also be compositionally and mechanically layered

  19. Sequential therapy with "vacuum sealing drainage-artificial dermis implantation-thin partial thickness skin grafting" for deep and infected wound surfaces in children.

    PubMed

    Yuan, X-G; Zhang, X; Fu, Y-X; Tian, X-F; Liu, Y; Xiao, J; Li, T-W; Qiu, L

    2016-05-01

    To evaluate the efficacy of a "vacuum sealing drainage (VSD) - artificial dermis implantation (ADI) - thin partial thickness skin grafting (TSG)" sequential therapy for deep and infected wounds in children. Fifty-three pediatric patients with deep and infected wounds were treated with sequential VSD-ADI-TSG therapy. The efficacy of this treatment was compared with that of the surgical debridement-change dressings-thin partial thickness skin grafting previously performed on 20 patients. Survival of tissue grafts, color and flexibility, subcutaneous fullness and scar formation of the graft site were examined and compared. The sequential therapy combined the advantages of the VSD treatment, in reducing tissue necrosis and infection on the wound surfaces and promoting the growth of granulation tissue, with the enhancement of grafting by artificial dermis. Compared with the 20 controls, skin grafted on the artificial dermis was more smooth and glossy, while the textures of the region were more elastic, and the scars were significantly lighter in Vancouver scale. The sequential VSD-ADI-TSG therapy is a simple and effective treatment for children with deep and infected wounds. IV. Copyright © 2016. Published by Elsevier Masson SAS.

  20. SU-F-T-414: Mathematical Formulation of Gantry Starting Angle for Right Medial Tangential Arc in Left Intact Partial Breast Irradiation Using Volumetric Modulated Arc Therapy (VMAT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giri, U; Sarkar, B; Kaur, H

    Purpose: To choose appropriate gantry starting angle for partial left breast irradiation using volumetric modulated arc therapy (VMAT). Methods: A random patient of left breast carcinoma was selected for this study. The slice which was selected for this mathematical formulation was having maximum breast thickness and maximum medial and lateral tangential distance. After this appropriate isocenter was chosen on that CT slice. The distances between various points were measured by the measuring tool in Monaco 5.00.04. Using the various trigonometric equations, a final equation was derived which shows the relationship between Gantry start angle, isocenter Location and tissue thickness. Results:more » The final equation for gantry start for right medial tangential arc is given asStarting angle = 270°+tan^(−1)(sin(θ)/(x-1/x-2 +cosθ))The above equation was tested for 10 cases and it was found to be appropriate for all the cases. Conclusion: Gantry starting angle for partial arc irradiation depends upon Breast thickness, Distance between Medial and lateral tangent and isocenter location.« less

  1. The introduction of a protocol for the use of biobrane for facial burns in children.

    PubMed

    Rogers, A D; Adams, S; Rode, H

    2011-01-01

    BIOBRANE HAS BECOME AN INDISPENSIBLE DRESSING WITH THREE ESTABLISHED INDICATIONS IN ACUTE BURNS CARE AT OUR INSTITUTION: (1) as the definitive dressing of superficial partial thickness facial burns, (2) after tangential excision of deep burns when autograft or cadaver skin is unavailable, and (3) for graft reduction. This paper details our initial experience of Biobrane for the management of superficial partial thickness facial burns in children and the protocol that was compiled for its optimal use. A retrospective analysis of theatre records, case notes and photographs was performed to evaluate our experience with Biobrane over a one-year period. Endpoints included length of stay, analgesic requirements, time to application of Biobrane, healing times, and aesthetic results. Historical controls were used to compare the results with our previous standard of care. 87 patients with superficial partial thickness burns of the face had Biobrane applied during this period. By adhering to the protocol we were able to demonstrate significant reductions in hospital stay, healing time, analgesic requirements, nursing care, with excellent cosmetic results. The protocol is widely accepted by all involved in the optimal management of these patients, including parents, anaesthetists, and nursing staff.

  2. The use of Hyalomatrix PA in the treatment of deep partial-thickness burns.

    PubMed

    Gravante, Gianpiero; Delogu, Daniela; Giordan, Nicola; Morano, Giuseppina; Montone, Antonio; Esposito, Gaetano

    2007-01-01

    Since 2001, Hyalomatrix PA (Fidia Advanced Biopolymers, Abano Terme, Italy) has been used in our center on pediatric burned patients as a temporary dermal substitute to cover deep partial-thickness burns after dermabrasion. This "bridge" treatment was adopted to remove necrotic debris (dermabrasion) and to stimulate regeneration in a humid and protected environment (Hyalomatrix PA). We present results obtained with this approach. On the third to fifth day after admission, dermabrasion was practiced on deep burned areas, which were covered with Hyalomatrix PA. Change of dressings was performed every 7 days. On day 21, those areas still without signs of recovery were removed with classic escharectomy and covered with thin skin grafts. We treated 300 patients. Sixty-one percent needed only one dermabrasion treatment, 22.3% (67 patients) more than one, and 16.7% (50 patients) the classic escharectomy. A total of 83% of patients healed within 21 days. Our study suggests that the combination of dermabrasion with a temporary dermal substitute could be a good and feasible approach for treatment of deep partial-thickness burns. Prospective randomized studies are now necessary to compare our protocol with the gold standard treatment of topical dressings.

  3. Rotation Capacity of Bolted Flush End-Plate Stiffened Beam-to-Column Connection

    NASA Astrophysics Data System (ADS)

    Ostrowski, Krzysztof; Kozłowski, Aleksander

    2017-06-01

    One of the flexibility parameters of semi-rigid joints is rotation capacity. Plastic rotation capacity is especially important in plastic design of framed structures. Current design codes, including Eurocode 3, do not posses procedures enabling designers to obtain value of rotation capacity. In the paper the calculation procedure of the rotation capacity for stiffened bolted flush end-plate beam-to-column connections has been proposed. Theory of experiment design was applied with the use of Hartley's PS/DS-P:Ha3 plan. The analysis was performed with the use of finite element method (ANSYS), based on the numerical experiment plan. The determination of maximal rotation angle was carried out with the use of regression analysis. The main variables analyzed in parametric study were: pitch of the bolt "w" (120-180 mm), the distance between the bolt axis and the beam upper edge cg1 (50-90 mm) and the thickness of the end-plate tp (10-20 mm). Power function was proposed to describe available rotation capacity of the joint. Influence of the particular components on the rotation capacity was also investigated. In the paper a general procedure for determination of rotation capacity was proposed.

  4. Enhanced optical rotation and diminished depolarization in diffusive scattering from a chiral liquid

    NASA Astrophysics Data System (ADS)

    Silverman, M. P.; Strange, Wayne; Badoz, J.; Vitkin, I. A.

    1996-02-01

    Optical rotation and degree of polarization of linearly polarized light were observed by forward, lateral, and back scattering from solutions of D-glucose containing a dispersion of micron-size polystyrene spheres. Rotations increased linearly with glucose concentration at a rate determined by the microsphere concentration and were large even at optical thicknesses sufficiently great to extinguish transmission of the incident beam. Depolarization of light with increasing microsphere concentration occurred at a much slower rate in chiral glucose solution than in pure water. These experiments suggest new possibilities for studying turbid chiral media for which light transmission and specular reflection techniques are inappropriate.

  5. Helioseismic Constraints on the Gradient of Angular Velocity at the Base of the Solar Convection Zone

    NASA Technical Reports Server (NTRS)

    Kosovichev, A. G.

    1996-01-01

    The layer of transition from the nearly rigid rotation of the radiative interior to the latitudinal differential rotation of the convection zone plays a significant role in the internal dynamics of the Sun. Using rotational splitting coefficients of the p-mode frequencies, obtained during 1986-1990 at the Big Bear Solar Observatory, we have found that the thickness of the transitional layer is 0.09 +/- 0.04 solar radii (63 +/- 28 Mm), and that most of the transition occurs beneath the adiabatically stratified part of the convection zone, as suggested by the dynamo theories of the 22 yr solar activity cycle.

  6. Graft Utilization in the Bridging Reconstruction of Irreparable Rotator Cuff Tears: A Systematic Review.

    PubMed

    Lewington, Matthew R; Ferguson, Devin P; Smith, T Duncan; Burks, Robert; Coady, Catherine; Wong, Ivan Ho-Bun

    2017-11-01

    Rotator cuff tears are one of the most common conditions affecting the shoulder. Because of the difficulty in managing massive rotator cuff tears and the inability of standard techniques to prevent arthropathy, surgeons have developed several novel techniques to improve outcomes and ideally alter the natural history. To systematically review the existing literature and analyze reported outcomes to evaluate the effectiveness of using a bridging graft reconstruction technique to treat large to massive irreparable rotator cuff tears. Systematic review. A systematic search of PubMed, EMBASE, CINAHL, and CENTRAL was employed with the key terms "tear," "allograft," and "rotator cuff." Eligibility was determined by a 3-phase screening process according to the outlined inclusion/exclusion criteria. Data in relation to the primary and secondary outcomes were summarized. The results were synthesized according to the origin of the graft and the level of evidence. Fifteen studies in total were included in this review: 2 comparative studies and 13 observational case series. Both the biceps tendon and the fascia lata autograft groups had significantly superior structural integrity rates on magnetic resonance imaging at 12-month minimum follow-up when compared with their partial primary repair counterparts (58% vs 26%, P = .036; 79% vs 58%, P < .05), respectively. Multiple noncomparative case series investigating allografts, xenografts, and synthetic materials for bridging reconstruction of large to massive rotator cuff tears demonstrated high structural healing rates (74%-90%, 73%-100%, and 60%-90%, respectively). Additionally, both comparative studies and case series demonstrated a general improvement of patients' functional outcome scores. Using a graft for an anatomic bridging rotator cuff repair results in improved function on objective testing and may be functionally better than nonanatomic or partial repair of large to massive rotator cuff tears. Allograft or xenograft techniques appear to be favorable options, given demonstrated functional improvement, imaging-supported graft survival, and lack of harvest complication risk. More high-quality randomized controlled studies are needed to further assess this technique.

  7. Analysis of the Rotation-Torsion Spectrum of CH_2DOH Within the e_0, e_1, and o_1 Torsional Levels

    NASA Astrophysics Data System (ADS)

    Coudert, L. H.; Pearson, John C.; Yu, Shanshan; Margules, L.; Motiyenko, R. A.; Klee, S.

    2013-06-01

    Since the first assignments of Quade and coworkers, a more satisfactory understanding of the spectrum of CH_2DOH has now been achieved. Thanks to a multidimensional potential energy surface and to a new theoretical approach accounting for the internal rotation of a partially deuterated methyl group, 76 torsional subbands could be identified in the microwave and FIR domains. 8356 rotation and rotation-torsion transitions were also assigned for the three lowest lying torsional levels, e_0, e_1, and o_1, in the microwave and terahertz domains and were analyzed with empirical models. In this paper, a new approach aimed at accounting for the rotation-torsion energy levels of CH_2DOH will be presented. It is based on the exact expression of the generalized 4× 4 inertia tensor of the molecule and accounts for the C_s symmetry of the partially deuterated methyl group, for the dependence of the rotational constants on the angle of internal rotation, and for the rotation-torsion Coriolis coupling. This approach will be used to analyze high-resolution data involving the three lowest lying torsional levels, up to k=11. In addition to the microwave data reported recently,^d new transitions recorded in the terahertz domain at JPL will be analyzed. The results of the analysis will be presented in the paper and the parameters determined in the analysis will be discussed. Quade and Suenram, J. Chem. Phys. {73} (1980) 1127; and Su and Quade, J. Mol. Spec. {134} (1989) 290. Lauvergnat, Coudert, Klee, and Smirnov, J. Mol. Spec. {256} (2009) 204. El Hilali, Coudert, Konov, and Klee, J. Chem. Phys. {135} (2011) 194309. Pearson, Yu, and Drouin, J. Mol. Spec. {280} (2012) 119. Quade and Lin, J. Chem. Phys. {38} (1963) 540.

  8. Partial IK1 blockade destabilizes spiral wave rotation center without inducing wave breakup and facilitates termination of reentrant arrhythmias in ventricles.

    PubMed

    Kushiyama, Yasunori; Honjo, Haruo; Niwa, Ryoko; Takanari, Hiroki; Yamazaki, Masatoshi; Takemoto, Yoshio; Sakuma, Ichiro; Kodama, Itsuo; Kamiya, Kaichiro

    2016-09-01

    It has been reported that blockade of the inward rectifier K(+) current (IK1) facilitates termination of ventricular fibrillation. We hypothesized that partial IK1 blockade destabilizes spiral wave (SW) re-entry, leading to its termination. Optical action potential (AP) signals were recorded from left ventricles of Langendorff-perfused rabbit hearts with endocardial cryoablation. The dynamics of SW re-entry were analyzed during ventricular tachycardia (VT), induced by cross-field stimulation. Intercellular electrical coupling in the myocardial tissue was evaluated by the space constant. In separate experiments, AP recordings were made using the microelectrode technique from right ventricular papillary muscles of rabbit hearts. Ba(2+) (10-50 μM) caused a dose-dependent prolongation of VT cycle length and facilitated termination of VT in perfused hearts. Baseline VT was maintained by a stable rotor, where an SW rotated around an I-shaped functional block line (FBL). Ba(2+) at 10 μM prolonged I-shaped FBL and phase-singularity trajectory, whereas Ba(2+) at 50 μM transformed the SW rotation dynamics from a stable linear pattern to unstable circular/cycloidal meandering. The SW destabilization was not accompanied by SW breakup. Under constant pacing, Ba(2+) caused a dose-dependent prolongation of APs, and Ba(2+) at 50 μM decreased conduction velocity. In papillary muscles, Ba(2+) at 50 μM depolarized the resting membrane potential. The space constant was increased by 50 μM Ba(2+) Partial IK1 blockade destabilizes SW rotation dynamics through a combination of prolongation of the wave length, reduction of excitability, and enhancement of electrotonic interactions, which facilitates termination of ventricular tachyarrhythmias. Copyright © 2016 the American Physiological Society.

  9. Mental Health Has a Stronger Association with Patient-Reported Shoulder Pain and Function Than Tear Size in Patients with Full-Thickness Rotator Cuff Tears.

    PubMed

    Wylie, James D; Suter, Thomas; Potter, Michael Q; Granger, Erin K; Tashjian, Robert Z

    2016-02-17

    Patient-reported outcome measures have increasingly accompanied objective examination findings in the evaluation of orthopaedic interventions. Our objective was to determine whether a validated measure of mental health (Short Form-36 Mental Component Summary [SF-36 MCS]) or measures of tear severity on magnetic resonance imaging were more strongly associated with self-assessed shoulder pain and function in patients with symptomatic full-thickness rotator cuff tears. One hundred and sixty-nine patients with full-thickness rotator cuff tears were prospectively enrolled. Patients completed the Short Form-36, visual analog scales for shoulder pain and function, the Simple Shoulder Test (SST), and the American Shoulder and Elbow Surgeons (ASES) instrument at the time of diagnosis. Shoulder magnetic resonance imaging examinations were reviewed to document the number of tendons involved, tear size, tendon retraction, and tear surface area. Age, sex, body mass index, number of medical comorbidities, smoking status, and Workers' Compensation status were recorded. Bivariate correlations and multivariate regression models were calculated to identify associations with baseline shoulder scores. The SF-36 MCS had the strongest correlation with the visual analog scale for shoulder pain (Pearson correlation coefficient, -0.48; p < 0.001), the visual analog scale for shoulder function (Pearson correlation coefficient, -0.33; p < 0.001), the SST (Pearson correlation coefficient, 0.37; p < 0.001), and the ASES score (Pearson correlation coefficient, 0.51; p < 0.001). Tear severity only correlated with the visual analog scale for shoulder function; the Pearson correlation coefficient was 0.19 for tear size (p = 0.018), 0.18 for tendon retraction (p = 0.025), 0.18 for tear area (p = 0.022), and 0.20 for the number of tendons involved (p = 0.011). Tear severity did not correlate with other scores in bivariate correlations (all p > 0.05). In all multivariate models, the SF-36 MCS had the strongest association with the visual analog scale for shoulder pain, the visual analog scale for shoulder function, the SST, and the ASES score (all p < 0.001). Patient mental health may play an influential role in patient-reported pain and function in patients with full-thickness rotator cuff tears. Further studies are needed to determine its effect on the outcome of the treatment of rotator cuff disease. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  10. Requirements, Technology and Configuration Evaluation for Crash Survivable Flight Data Recording (CSFDR) System

    DTIC Science & Technology

    1981-03-23

    25% Rotational angle - 350 degrees Temperature range - -65°C to + 125°C Vibration - 15 g Shock - 50 g Rotational load life - 25,000,000...structed of multi-layered metal foils, vacuum deposited on thin films of Mylar, Kapton, or similar plastics) slowly outgas and contaminate their own...armor. Intumescent coating is a paint derivative, which swells 5 to 50 times its original thickness when exposed to high temperatures ( 350 ° to 500

  11. A spectrum synthesis program for binary stars

    NASA Technical Reports Server (NTRS)

    Linnell, Albert P.; Hubeny, Ivan

    1994-01-01

    A new program produces synthetic spectra of binary stars at arbitrary values of orbital longitude, including longitudes of partial or complete eclipse. The stellar components may be distorted, either tidally or rotationally, or both. Either or both components may be rotating nonsynchronously. We illustrate the program performance with two cases: EE Peg, an eclipsing binary with small distortion, and SX Aur, an eclipsing binary that is close to contact.

  12. Structural development of the onshore Otway passive margin (Australia): the interaction of rotating syn-sedimentary faults

    NASA Astrophysics Data System (ADS)

    Tanner, David C.; Ziesch, Jennifer; Krawczyk, Charlotte M.

    2017-04-01

    Within the context of long-term CO2 storage integrity, we interpreted the faults within the 2.2 km thick, syn-rift, Late Cretaceous to Recent sediments below the CO2CRC Otway Project site in Australia using a detailed interpretation of a 3-D reflection seismic cube (32.3 km×14.35 km × 4100 ms TWT). All the faults in the onshore Otway passive margin basin in this area were active to varying degrees during sedimentation, between ca. 120 and 50 Ma, before they died out. From analysis of fault juxtaposition and fault tip-line propagation maps, as well as analysis of individual stratigraphic thickness maps, we determine the direction and incremental amount of syn-sedimentary movement on each fault. Thickening of the hanging-walls of the faults occurred, as is typical for syn-sedimentary faults. However, we also determine that substantial local footwall thinning took place. Although the syn-sedimentary behaviour of the faults was constantly maintained until 50 Ma, there were two main phases of footwall thinning, separated by a quiescent phase. We postulate that these phases of footwall thinning represent rotation of the fault blocks that correlate with prograding sediment pulses within the passive margin. The rotation of the fault blocks occurred simultaneously, i.e., they could only rotate if they interacted.

  13. A numerical and experimental study of three-dimensional liquid sloshing in a rotating spherical container

    NASA Technical Reports Server (NTRS)

    Chen, Kuo-Huey; Kelecy, Franklyn J.; Pletcher, Richard H.

    1992-01-01

    A numerical and experimental study of three dimensional liquid sloshing inside a partially-filled spherical container undergoing an orbital rotating motion is described. Solutions of the unsteady, three-dimensional Navier-Stokes equations for the case of a gradual spin-up from rest are compared with experimental data obtained using a rotating test rig fitted with two liquid-filled spherical tanks. Data gathered from several experiments are reduced in terms of a dimensionless free surface height for comparison with transient results from the numerical simulations. The numerical solutions are found to compare favorably with the experimental data.

  14. Time-dependent dynamical behavior of surface tension on rotating fluids under microgravity environment

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Tsao, Y. D.; Hong, B. B.; Leslie, F. W.

    1988-01-01

    Time dependent evolutions of the profile of free surface (bubble shapes) for a cylindrical container partially filled with a Newtonian fluid of constant density, rotating about its axis of symmetry, have been studied. Numerical computations of the dynamics of bubble shapes have been carried out with the following situations: (1) linear functions of spin-up and spin-down in low and microgravity environments, (2) step functions of spin-up and spin-down in a low gravity environment, and (3) sinusoidal function oscillation of gravity environment in high and low rotating cylinder speeds.

  15. Spatially periodic patterns in rotating fluids: a new spin on the old "soup-can race"

    NASA Astrophysics Data System (ADS)

    Carnevali, Antonino; Carnevali, Dora; Christ, Jessica

    2000-11-01

    A student's investigation of the old "soup-can race" experiment revealed spatially periodic structures at the surface of the rotating fluid. To better observe this effect, the experiment was transferred to a test bench, where an electric motor was used to spin a cylindrical bottle, partially filled with fluids of varied densities, about its longitudinal axis. A photogate and event-counter software provided real-time measurements of the rotational frequency. Various cell-formation patterns were observed. Experimental results will be presented, and connections with the theory will be explored.

  16. Collisional evolution of rotating, non-identical particles. [in Saturn rings

    NASA Technical Reports Server (NTRS)

    Salo, H.

    1987-01-01

    Hameen-Anttila's (1984) theory of self-gravitating collisional particle disks is extended to include the effects of particle spin. Equations are derived for the coupled evolution of random velocities and spins, showing that friction and surface irregularity both reduce the local velocity dispersion and transfer significant amounts of random kinetic energy to rotational energy. Results for the equilibrium ratio of rotational energy to random kinetic energy are exact not only for identical nongravitating mass points, but also if finite size, self-gravitating forces, or size distribution are included. The model is applied to the dynamics of Saturn's rings, showing that the inclusion of rotation reduces the geometrical thickness of the layer of cm-sized particles to, at most, about one-half, with large particles being less affected.

  17. Rotator Cuff Tendinopathy: Navigating the Diagnosis-Management Conundrum.

    PubMed

    Lewis, Jeremy; McCreesh, Karen; Roy, Jean-Sébastien; Ginn, Karen

    2015-11-01

    Synopsis The hallmark characteristics of rotator cuff (RC) tendinopathy are pain and weakness, experienced most commonly during shoulder external rotation and elevation. Assessment is complicated by nonspecific clinical tests and the poor correlation between structural failure and symptoms. As such, diagnosis is best reached by exclusion of other potential sources of symptoms. Symptomatic incidence and prevalence data currently cannot be determined with confidence, primarily as a consequence of a lack of diagnostic accuracy, as well as the uncertainty as to the location of symptoms. People with symptoms of RC tendinopathy should derive considerable comfort from research that consistently demonstrates improvement in symptoms with a well-structured and graduated exercise program. This improvement is equivalent to outcomes reported in surgical trials, with the additional generalized benefits of exercise, less sick leave, a faster return to work, and reduced costs to the health care system. This evidence covers the spectrum of conditions that include symptomatic RC tendinopathy and atraumatic partial- and full-thickness RC tears. The principles guiding exercise treatment for RC tendinopathy include relative rest, modification of painful activities, an exercise strategy that initially does not exacerbate pain, controlled reloading, and gradual progression from simple to complex shoulder movements. Evidence also exists for a specific exercise program being beneficial for people with massive inoperable tears of the RC. Education is an essential component of rehabilitation, and attention to lifestyle factors (smoking cessation, nutrition, stress, and sleep management) may enhance outcomes. Outcomes may also be enhanced by subgrouping RC tendinopathy presentations and directing treatment strategies according to the clinical presentation and the patient's response to shoulder symptom modification procedures outlined herein. There are substantial deficits in our knowledge regarding RC tendinopathy that need to be addressed to further improve clinical outcomes. J Orthop Sports Phys Ther 2015;45(11):923-937. Epub 21 Sep 2015. doi:10.2519/jospt.2015.5941.

  18. Composite lamination method

    NASA Technical Reports Server (NTRS)

    Dickerson, G. E. (Inventor)

    1977-01-01

    A process was developed for preparing relatively thick composite laminate structure wherein thin layers of prepreg tapes are assembled, these thin layers are cut into strips that are partially cured, and stacked into the desired thickness with uncured prepreg disposed between each layer of strips. The formed laminate is finally cured and thereafter machined to the desired final dimensions.

  19. Intelligence and cortical thickness in children with complex partial seizures.

    PubMed

    Tosun, Duygu; Caplan, Rochelle; Siddarth, Prabha; Seidenberg, Michael; Gurbani, Suresh; Toga, Arthur W; Hermann, Bruce

    2011-07-15

    Prior studies on healthy children have demonstrated regional variations and a complex and dynamic relationship between intelligence and cerebral tissue. Yet, there is little information regarding the neuroanatomical correlates of general intelligence in children with epilepsy compared to healthy controls. In vivo imaging techniques, combined with methods for advanced image processing and analysis, offer the potential to examine quantitative mapping of brain development and its abnormalities in childhood epilepsy. A surface-based, computational high resolution 3-D magnetic resonance image analytic technique was used to compare the relationship of cortical thickness with age and intelligence quotient (IQ) in 65 children and adolescents with complex partial seizures (CPS) and 58 healthy controls, aged 6-18 years. Children were grouped according to health status (epilepsy; controls) and IQ level (average and above; below average) and compared on age-related patterns of cortical thickness. Our cross-sectional findings suggest that disruption in normal age-related cortical thickness expression is associated with intelligence in pediatric CPS patients both with average and below average IQ scores. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Broadband and wide-angle light harvesting by ultra-thin silicon solar cells with partially embedded dielectric spheres.

    PubMed

    Yang, Zhenhai; Shang, Aixue; Qin, Linling; Zhan, Yaohui; Zhang, Cheng; Gao, Pingqi; Ye, Jichun; Li, Xiaofeng

    2016-04-01

    We propose a design of crystalline silicon thin-film solar cells (c-Si TFSCs, 2 μm-thick) configured with partially embedded dielectric spheres on the light-injecting side. The intrinsic light trapping and photoconversion are simulated by the complete optoelectronic simulation. It shows that the embedding depth of the spheres provides an effective way to modulate and significantly enhance the optical absorption. Compared to the conventional planar and front sphere systems, the optimized partially embedded sphere design enables a broadband, wide-angle, and strong optical absorption and efficient carrier transportation. Optoelectronic simulation predicts that a 2 μm-thick c-Si TFSC with half-embedded spheres shows an increment of more than 10  mA/cm2 in short-circuit current density and an enhancement ratio of more than 56% in light-conversion efficiency, compared to the conventional planar counterparts.

  1. Process and apparatus for measuring degree of polarization and angle of major axis of polarized beam of light

    DOEpatents

    Decker, Derek E.; Toeppen, John S.

    1994-01-01

    Apparatus and process are disclosed for calibrating measurements of the phase of the polarization of a polarized beam and the angle of the polarized optical beam's major axis of polarization at a diagnostic point with measurements of the same parameters at a point of interest along the polarized beam path prior to the diagnostic point. The process is carried out by measuring the phase angle of the polarization of the beam and angle of the major axis at the point of interest, using a rotatable polarizer and a detector, and then measuring these parameters again at a diagnostic point where a compensation apparatus, including a partial polarizer, which may comprise a stack of glass plates, is disposed normal to the beam path between a rotatable polarizer and a detector. The partial polarizer is then rotated both normal to the beam path and around the axis of the beam path until the detected phase of the beam polarization equals the phase measured at the point of interest. The rotatable polarizer at the diagnostic point may then be rotated manually to determine the angle of the major axis of the beam and this is compared with the measured angle of the major axis of the beam at the point of interest during calibration. Thereafter, changes in the polarization phase, and in the angle of the major axis, at the point of interest can be monitored by measuring the changes in these same parameters at the diagnostic point.

  2. Comparison of Dorsal Intercostal Artery Perforator Propeller Flaps and Bilateral Rotation Flaps in Reconstruction of Myelomeningocele Defects.

    PubMed

    Tenekeci, Goktekin; Basterzi, Yavuz; Unal, Sakir; Sari, Alper; Demir, Yavuz; Bagdatoglu, Celal; Tasdelen, Bahar

    2018-04-09

    Bilateral rotation flaps are considered the workhorse flaps in reconstruction of myelomeningocele defects. Since the introduction of perforator flaps in the field of reconstructive surgery, perforator flaps have been used increasingly in the reconstruction of various soft tissue defects all over the body because of their appreciated advantages. The aim of this study was to compare the complications and surgical outcomes between bilateral rotation flaps and dorsal intercostal artery perforator (DICAP) flaps in the soft tissue reconstruction of myelomeningocele defects. Between January 2005-February 2017, we studied 47 patients who underwent reconstruction of myelomeningocele defects. Patient demographics, operative data, and postoperative data were reviewed retrospectively and are included in the study. We found no statistically significant differences in patient demographics and surgical complications between these two groups; this may be due to small sample size. With regard to complications-partial flap necrosis, cerebrospinal fluid (CSF) leakage, necessity for reoperation, and wound infection-DICAP propeller flaps were clinically superior to rotation flaps. Partial flap necrosis was associated with CSF leakage and wound infection, and CSF leakage was associated with wound dehiscence. Although surgical outcomes obtained with DICAP propeller flaps were clinically superior to those obtained with rotation flaps, there was no statistically significant difference between the two patient groups. A well-designed comparative study with adequate sample size is needed. Nonetheless, we suggest using DICAP propeller flaps for reconstruction of large myelomeningocele defects.

  3. Effects of partial harvest on the carbon stores in Douglas-fir/western hemlock forests: a simulation study

    Treesearch

    Mark E. Harmon; Adam Moreno; James B. Domingo

    2009-01-01

    The STANDCARB 2.0 model was used to examine the effects of partial harvest of trees within stands on forest-related carbon (C) stores in a typical Pacific Northwest Pseudotsuga/Tsuga forest. For harvest rotation intervals of 20 to 250 years the effect of completely dispersed (that is, a checkerboard) versus completely aggregated cutting patterns (...

  4. Fundamentally Distributed Information Processing Integrates the Motor Network into the Mental Workspace during Mental Rotation.

    PubMed

    Schlegel, Alexander; Konuthula, Dedeepya; Alexander, Prescott; Blackwood, Ethan; Tse, Peter U

    2016-08-01

    The manipulation of mental representations in the human brain appears to share similarities with the physical manipulation of real-world objects. In particular, some neuroimaging studies have found increased activity in motor regions during mental rotation, suggesting that mental and physical operations may involve overlapping neural populations. Does the motor network contribute information processing to mental rotation? If so, does it play a similar computational role in both mental and manual rotation, and how does it communicate with the wider network of areas involved in the mental workspace? Here we used multivariate methods and fMRI to study 24 participants as they mentally rotated 3-D objects or manually rotated their hands in one of four directions. We find that information processing related to mental rotations is distributed widely among many cortical and subcortical regions, that the motor network becomes tightly integrated into a wider mental workspace network during mental rotation, and that motor network activity during mental rotation only partially resembles that involved in manual rotation. Additionally, these findings provide evidence that the mental workspace is organized as a distributed core network that dynamically recruits specialized subnetworks for specific tasks as needed.

  5. Accuracy of Currently Used Paper Burn Diagram vs a Three-Dimensional Computerized Model.

    PubMed

    Benjamin, Nicole C; Lee, Jong O; Norbury, William B; Branski, Ludwik K; Wurzer, Paul; Jimenez, Carlos J; Benjamin, Debra A; Herndon, David N

    Burn units have historically used paper diagrams to estimate percent burn; however, unintentional errors can occur. The use of a computer program that incorporates wound mapping from photographs onto a three-dimensional (3D) human diagram could decrease subjectivity in preparing burn diagrams and subsequent calculations of TBSA burned. Analyses were done on 19 burned patients who had an estimated TBSA burned of ≥20%. The patients were admitted to Shriners Hospitals for Children or the University of Texas Medical Branch in Galveston, Texas, from July 2012 to September 2013 for treatment. Digital photographs were collected before the patient's first surgery. Using BurnCase 3D (RISC Software GmbH, Hagenberg, Austria), a burn mapping software, the user traced partial- and full-thickness burns from photographs. The program then superimposed tracings onto a 3D model and calculated percent burned. The results were compared with the Lund and Browder diagrams completed after the first operation. A two-tailed t-test was used to calculate statistical differences. For partial-thickness burns, burn sizes calculated using Lund and Browder diagrams were significantly larger than those calculated using BurnCase 3D (15% difference, P < .01). The opposite was found for full-thickness burns, with burn sizes being smaller when calculated using Lund and Browder diagrams (11% difference, P < .05). In conclusion, substantial differences exist in percent burn estimations derived from BurnCase 3D and paper diagrams. In our studied cohort, paper diagrams were associated with overestimation of partial-thickness burn size and underestimation of full-thickness burn size. Additional studies comparing BurnCase 3D with other commonly used methods are warranted.

  6. Process stability and morphology optimization of very thick 4H-SiC epitaxial layers grown by chloride-based CVD

    NASA Astrophysics Data System (ADS)

    Yazdanfar, M.; Stenberg, P.; Booker, I. D.; Ivanov, I. G.; Kordina, O.; Pedersen, H.; Janzén, E.

    2013-10-01

    The development of a chemical vapor deposition (CVD) process for very thick silicon carbide (SiC) epitaxial layers suitable for high power devices is demonstrated by epitaxial growth of 200 μm thick, low doped 4H-SiC layers with excellent morphology at growth rates exceeding 100 μm/h. The process development was done in a hot wall CVD reactor without rotation using both SiCl4 and SiH4+HCl precursor approaches to chloride based growth chemistry. A C/Si ratio <1 and an optimized in-situ etch are shown to be the key parameters to achieve 200 μm thick, low doped epitaxial layers with excellent morphology.

  7. Gravity Probe-B Spacecraft attitude control based on the dynamics of slosh wave-induced fluid stress distribution on rotating dewar container of cryogenic propellant

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Lee, C. C.; Leslie, F. W.

    1991-01-01

    The dynamical behavior of fluids, in particular the effect of surface tension on partially-filled rotating fluids, in a full-scale Gravity Probe-B Spacecraft propellant dewar tank imposed by various frequencies of gravity jitters have been investigated. Results show that fluid stress distribution exerted on the outer and inner walls of rotating dewar are closely related to the characteristics of slosh waves excited on the liquid-vapor interface in the rotating dewar tank. This can provide a set of tool for the spacecraft dynamic control leading toward the control of spacecraft unbalance caused by the uneven fluid stress distribution due to slosh wave excitations.

  8. Steadily oscillating axial bands of binary granules in a nearly filled coaxial cylinder.

    PubMed

    Inagaki, Shio; Ebata, Hiroyuki; Yoshikawa, Kenichi

    2015-01-01

    Granular materials often segregate under mechanical agitation such as flowing, shaking, or rotating, in contrast to an expectation of mixing. It is well known that bidisperse mixtures of granular materials in a partially filled rotating cylinder exhibit monotonic coarsening dynamics of segregation. Here we report the steady oscillation of segregated axial bands under the stationary rotation of a nearly filled coaxial cylinder for O(10(3)) revolutions. The axial bands demonstrate steady back-and-forth motion along the axis of rotation. Experimental findings indicated that these axial band dynamics are driven by global convection throughout the system. The essential features of the spatiotemporal dynamics are reproduced with a simple phenomenological equation that incorporates the effect of global convection.

  9. Cold quantum-controlled rotationally inelastic scattering of HD with H2 and D2 reveals collisional partner reorientation

    NASA Astrophysics Data System (ADS)

    Perreault, William E.; Mukherjee, Nandini; Zare, Richard N.

    2018-05-01

    Molecular interactions are best probed by scattering experiments. Interpretation of these studies has been limited by lack of control over the quantum states of the incoming collision partners. We report here the rotationally inelastic collisions of quantum-state prepared deuterium hydride (HD) with H2 and D2 using a method that provides an improved control over the input states. HD was coexpanded with its partner in a single supersonic beam, which reduced the collision temperature to 0-5 K, and thereby restricted the involved incoming partial waves to s and p. By preparing HD with its bond axis preferentially aligned parallel and perpendicular to the relative velocity of the colliding partners, we observed that the rotational relaxation of HD depends strongly on the initial bond-axis orientation. We developed a partial-wave analysis that conclusively demonstrates that the scattering mechanism involves the exchange of internal angular momentum between the colliding partners. The striking differences between H2/HD and D2/HD scattering suggest the presence of anisotropically sensitive resonances.

  10. A novel method for rotation invariant palm print image stitching

    NASA Astrophysics Data System (ADS)

    Rao, Shishir Paramathma; Panetta, Karen; Agaian, Sos S.

    2017-05-01

    Although not as popular as fingerprint biometrics, palm prints have garnered interest in scientific community for the rich amount of distinctive information available on the palm. In this paper, a novel method for touchless palm print stitching to increase the effective area is presented. The method is not only rotation invariant but also able to robustly handle many distortions of touchless systems like illumination variations, pose variations etc. The proposed method also can handle partial palmprints, which have a high chance of occurrence in a scene of crime, by stitching them together to produce a much larger-to-full size palmprint for authentication purpose. Experiment results are shown for IIT-D palmprint database, from which pseudo partial palmprints were generated by cropping and randomly rotating them. Furthermore, the quality of stitching algorithm is determined by extensive computer simulations and visual analysis of the stitched image. Experimental results also show that the stitching significantly increases the area of palm image for feature point detection and hence provides a way to increase the accuracy and reliability of detection.

  11. Magnetic Resonance Imaging Findings in Symptomatic Patients After Arthroscopic Partial Meniscectomy for Torn Discoid Lateral Meniscus.

    PubMed

    Lee, Chang-Rack; Bin, Seong-Il; Kim, Jong-Min; Kim, Nam-Ki

    2016-11-01

    To evaluate the change in the thickness and width of the residual meniscus using magnetic resonance imaging (MRI) in patients who underwent arthroscopic partial meniscectomy for discoid lateral meniscus (DLM), to assess whether the degeneration of the articular cartilage in the lateral compartment of the knee progressed, and to evaluate clinical results. Among the patients who underwent arthroscopic partial meniscectomy for DLM between January 1997 and December 2011, those who were aged 40 or below at surgery were followed up for at least 3 years, and received at least 2 follow-up MRIs that were retrospectively reviewed. MRIs were done in symptomatic knees. Using MRI, the relative thickness and width were measured in the anterior horn, midportion, and posterior horn. To determine whether the degeneration of the lateral compartment would progress, the articular cartilage was graded based on the Outerbridge classification in MRIs. The clinical results were evaluated using the Lysholm score. A total of 20 patients (21 knees) were included. The average follow-up period was 6.8 years. In residual meniscus, the relative thickness of the midportion decreased from 9.0% ± 2.4% to 7.3% ± 2.3% (P < .001), the relative thickness of the anterior horn decreased from 15.6% ± 4.3% to 14.3% ± 6.7% (P = .030), and the relative thickness of the posterior horn decreased from 20.0% ± 4.4% to 16.7% ± 6.7% (P = .019). A decrease in the relative width was observed in the midportion (12.4% ± 4.8% to 10.9% ± 4.9%, P = .003). No significant changes in size were observed in the medial meniscus. A progression of degeneration in the lateral compartment was observed. However, the clinical results did not present significant changes. In symptomatic patients after arthroscopic partial meniscectomy for DLM, the thickness and width of the residual meniscus decreases over time. The arthritic change of the lateral compartment of the knee progressed. However, the change in the size of the residual meniscus was of unknown clinical significance. Level IV, therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Glenohumeral internal rotation deficit in throwing athletes: current perspectives

    PubMed Central

    Rose, Michael B; Noonan, Thomas

    2018-01-01

    Glenohumeral internal rotation deficit (GIRD) is an adaptive process in which the throwing shoulder experiences a loss of internal rotation (IR). GIRD has most commonly been defined by a loss of >20° of IR compared to the contralateral shoulder. Total rotational motion of the shoulder is the sum of internal and external rotation and may be more important than the absolute value of IR loss. Pathologic GIRD has been defined as a loss of IR combined with a loss of total rotational motion. The leading pathologic process in GIRD is posterior capsular and rotator-cuff tightness, due to the repetitive cocking that occurs with the overhead throwing motion. GIRD has been associated with numerous pathologic conditions, including posterior superior labral tears, partial articular-sided rotator-cuff tears, and superior labral anterior-to-posterior tears. The mainstay of treatment for patients with GIRD is posterior capsular stretching and strengthening to improve scapular mechanics. In patients who fail nonoperative therapy, shoulder arthroscopy can be performed. Arthroscopic surgery in the high-level throwing athlete should be to restore them to their functional baseline with the minimum amount of intervention possible. PMID:29593438

  13. Analytic Modeling of the Hydrodynamic, Thermal, and Structural Behavior of Foil Thrust Bearings

    NASA Technical Reports Server (NTRS)

    Bruckner, Robert J.; DellaCorte, Christopher; Prahl, Joseph M.

    2005-01-01

    A simulation and modeling effort is conducted on gas foil thrust bearings. A foil bearing is a self acting hydrodynamic device capable of separating stationary and rotating components of rotating machinery by a film of air or other gaseous lubricant. Although simple in appearance these bearings have proven to be complicated devices in analysis. They are sensitive to fluid structure interaction, use a compressible gas as a lubricant, may not be in the fully continuum range of fluid mechanics, and operate in the range where viscous heat generation is significant. These factors provide a challenge to the simulation and modeling task. The Reynolds equation with the addition of Knudsen number effects due to thin film thicknesses is used to simulate the hydrodynamics. The energy equation is manipulated to simulate the temperature field of the lubricant film and combined with the ideal gas relationship, provides density field input to the Reynolds equation. Heat transfer between the lubricant and the surroundings is also modeled. The structural deformations of the bearing are modeled with a single partial differential equation. The equation models the top foil as a thin, bending dominated membrane whose deflections are governed by the biharmonic equation. A linear superposition of hydrodynamic load and compliant foundation reaction is included. The stiffness of the compliant foundation is modeled as a distributed stiffness that supports the top foil. The system of governing equations is solved numerically by a computer program written in the Mathematica computing environment. Representative calculations and comparisons with experimental results are included for a generation I gas foil thrust bearing.

  14. Laparoscopic partial nephrectomy for renal tumor: Nagoya experience.

    PubMed

    Yoshikawa, Yoko; Ono, Yoshinari; Hattori, Ryohei; Gotoh, Momokazu; Yoshino, Yasushi; Katsuno, Satoshi; Katoh, Masashi; Ohshima, Shinichi

    2004-08-01

    To clarify the indication for a vascular clamp during laparoscopic partial nephrectomy, the clinical results of 17 patients who underwent the procedure for small renal tumors were reviewed. Seventeen patients with renal tumors were enrolled in our laparoscopic partial nephrectomy program between October 1999 and November 2003. During laparoscopy, a vascular clamp was used to remove the tumor mass and suture the incised renal parenchyma and urinary collecting system in 8 patients who had less-than-1-cm-thick renal parenchyma between the mass and the renal sinus or calices. In the remaining 9 patients, who had 1-cm-or-more-thick renal parenchyma between the mass and sinus or calices, renal bleeding was controlled using ultrasonic scissors, gauze tampon, argon beam coagulator, and fibrin glue. Sixteen patients were successfully treated with laparoscopy; one required conversion to open surgery because of uncontrollable bleeding. The average operative time was 4.5 hours, and average estimated bleeding volume was 301 mL. In the 8 patients requiring vascular clamping by forceps, the average ischemic time was 25 minutes. In all patients, the tumor mass was completely removed with negative surgical margins, and renal function was preserved. Three patients had prolonged urinary leakage for a mean of 21 days. Laparoscopic partial nephrectomy offers many advantages, including surgery that is both nephron sparing and minimally invasive. A vascular clamp was indicated for patients with less-than-1-cm-thick renal parenchyma between the tumor mass and renal sinus or calices.

  15. Rotary union for use with ultrasonic thickness measuring probe

    DOEpatents

    Nachbar, H.D.

    1992-09-15

    A rotary union for rotatably supporting an ultrasonic probe operable to nondestructively measure the thickness of steam generator tubes to determine the amount of corrosion experienced by the tubes includes a stationary body having a bore therethrough and an outlet drain, and a fitting rotatably mounted within the upper end of the body. The fitting has a bore aligned with the bore of the body. An electrical cable positioned within a water supply tube in an annular arrangement passes through the bore of the body and the bore of the fitting. This annular arrangement, in turn, is positioned within a connector element which extends outwardly from the fitting bore and is connected to the ultrasonic probe. An elastomeric lower bushing seals the annular arrangement to the lower end of the rotary union body and an elastomeric upper bushing seals the connector element to the fitting to permit the connector element and the ultrasonic probe connected thereto to rotate with the fitting relative to the body. The lower and upper bushings permit water to be passed through the annular arrangement and into the ultrasonic probe and thereafter discharged between the annular arrangement and the connector element to the outlet drain of the rotary union body. 5 figs.

  16. Exponential increase in the on-off ratio of conductance in organic memory devices by controlling the surface morphology of the devices

    NASA Astrophysics Data System (ADS)

    Vyas, Giriraj; Dagar, Parveen; Sahu, Satyajit

    2018-05-01

    We have shown an exponential increase in the ratio of conductance in the on and off states of switching devices by controlling the surface morphology of the thin films for the device by depositing at different rotational speeds. The pinholes which are preferred topography on the surface at higher rotational speed give rise to higher on-off ratio of current from the devices fabricated at the speed. The lower rotational speed contributes to higher thickness of the film and hence no switching. For thicker films, the domain is formed due to phase segregation between the two components in the film, which also indicates that the film is far from thermal equilibrium. At higher speed, there is very little scope of segregation when the film is drying up. Hence, there are only few pinholes on the surface of the film which are shallow. So, the filamentary mechanism of switching in memory devices can be firmly established by varying the speed of thin film deposition which leads to phase segregation of the materials. Thus, the formation of filament can be regulated by controlling the thickness and the surface morphology.

  17. Rotary union for use with ultrasonic thickness measuring probe

    DOEpatents

    Nachbar, Henry D.

    1992-01-01

    A rotary union for rotatably supporting an ultrasonic probe operable to nondestructively measure the thickness of steam generator tubes to determine the amount of corrosion experienced by the tubes includes a stationary body having a bore therethrough and an outlet drain, and a fitting rotatably mounted within the upper end of the body. The fitting has a bore aligned with the bore of the body. An electrical cable positioned within a water supply tube in an annular arrangement passes through the bore of the body and the bore of the fitting. This annular arrangement, in turn, is positioned within a connector element which extends outwardly from the fitting bore and is connected to the ultrasonic probe. An elastomeric lower bushing seals the annular arrangement to the lower end of the rotary union body and an elastomeric upper bushing seals the connector element to the fitting to permit the connector element and the ultrasonic probe connected thereto to rotate with the fitting relative to the body. The lower and upper bushings permit water to be passed through the annular arrangement and into the ultrasonic probe and thereafter discharged between the annular arrangement and the connector element to the outlet drain of the rotary union body.

  18. Target Track and Stabilization for Manportable Direct Fire Missiles.

    DTIC Science & Technology

    1981-11-01

    appeared to achieve resonable results, since there is always the possibility that summing weighted scores can be misleading, as was the case with the 1-3...coelostat and variable prism compensation approaches (Appendix, Reference 6) but both suffered from even greater size and complexity problems than approach...8 mm Thick 2 an. Al., Glass, etc. ( ( )Rotating Prisms (Rilley) -30 mm diam x 6 mm Thick 2 ea Germanium. Silicon. Zu On Searn motion ± max requires

  19. Design of a rear anamorphic attachment for digital cinematography

    NASA Astrophysics Data System (ADS)

    Cifuentes, A.; Valles, A.

    2008-09-01

    Digital taking systems for HDTV and now for the film industry present a particularly challenging design problem for rear adapters in general. The thick 3-channel prism block in the camera provides an important challenge in the design. In this paper the design of a 1.33x rear anamorphic attachment is presented. The new design departs significantly from the traditional Bravais condition due to the thick dichroic prism block. Design strategies for non-rotationally symmetric systems and fields of view are discussed. Anamorphic images intrinsically have a lower contrast and less resolution than their rotationally symmetric counterparts, therefore proper image evaluation must be considered. The interpretation of the traditional image quality methods applied to anamorphic images is also discussed in relation to the design process. The final design has a total track less than 50 mm, maintaining the telecentricity of the digital prime lens and taking full advantage of the f/1.4 prism block.

  20. Field dependent magnetic anisotropy of Ga0.2Fe0.8 thin films

    NASA Astrophysics Data System (ADS)

    Resnick, Damon A.; McClure, A.; Kuster, C. M.; Rugheimer, P.; Idzerda, Y. U.

    2011-04-01

    Using longitudinal MOKE in combination with a variable strength rotating magnetic field, called the rotational MOKE (ROTMOKE) method, we show that the magnetic anisotropy for a Ga0.2Fe0.8 single crystal film with a thickness of 17 nm, grown on GaAs (001) with a thick ZnSe buffer layer, depends linearly on the strength of the applied magnetic field. The torque moment curves generated using ROTMOKE are well fit with a model that accounts for the uniaxial, cubic, or fourfold anisotropy, as well as additional terms with a linear dependence on the applied magnetic field. The uniaxial and cubic anisotropy fields, taken from both the hard and the easy axis scans, are seen to remain field independent. The field dependent terms are evidence of a large affect of the magnetostriction and its contribution to the effective magnetic anisotropy in GaxFe1-x thin films.

  1. Magnetic modulation of inverse spin Hall effect in lateral spin-valves

    NASA Astrophysics Data System (ADS)

    Andrianov, T.; Vedyaev, A.; Dieny, B.

    2018-05-01

    We analytically investigated the spin-dependent transport properties in a lateral spin-valve device comprising pinned ferromagnetic electrodes allowing the injection of a spin current in a spin conducting channel where spin orbit scattering takes place. This produces an inverse spin Hall (ISHE) voltage across the thickness of the spin conducting channel. It is shown that by adding an extra soft ferromagnetic electrode with rotatable magnetization along the spin conducting channel, the ISHE generated voltage can be magnetically modulated by changing the magnetization orientation of this additional electrode. The dependence of the ISHE voltage on the direction of magnetization of the ferromagnetic electrode with rotatable magnetization was calculated in various configurations. Our results suggest that such structures could be considered as magnetic field sensors in situations where the total thickness of the sensor is constrained such as in hard disk drive readers.

  2. Universal Faraday Rotation in HgTe Wells with Critical Thickness

    NASA Astrophysics Data System (ADS)

    Shuvaev, A.; Dziom, V.; Kvon, Z. D.; Mikhailov, N. N.; Pimenov, A.

    2016-09-01

    The universal value of the Faraday rotation angle close to the fine structure constant (α ≈1 /137 ) is experimentally observed in thin HgTe quantum wells with a thickness on the border between trivial insulating and the topologically nontrivial Dirac phases. The quantized value of the Faraday angle remains robust in the broad range of magnetic fields and gate voltages. Dynamic Hall conductivity of the holelike carriers extracted from the analysis of the transmission data shows a theoretically predicted universal value of σx y=e2/h , which is consistent with the doubly degenerate Dirac state. On shifting the Fermi level by the gate voltage, the effective sign of the charge carriers changes from positive (holes) to negative (electrons). The electronlike part of the dynamic response does not show quantum plateaus and is well described within the classical Drude model.

  3. LUMINOSITY EVOLUTION OF GAMMA-RAY PULSARS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirotani, Kouichi, E-mail: hirotani@tiara.sinica.edu.tw

    2013-04-01

    We investigate the electrodynamic structure of a pulsar outer-magnetospheric particle accelerator and the resulting gamma-ray emission. By considering the condition for the accelerator to be self-sustained, we derive how the trans-magnetic-field thickness of the accelerator evolves with the pulsar age. It is found that the thickness is small but increases steadily if the neutron-star envelope is contaminated by sufficient light elements. For such a light element envelope, the gamma-ray luminosity of the accelerator is kept approximately constant as a function of age in the initial 10,000 yr, forming the lower bound of the observed distribution of the gamma-ray luminosity ofmore » rotation-powered pulsars. If the envelope consists of only heavy elements, on the other hand, the thickness is greater, but it increases less rapidly than a light element envelope. For such a heavy element envelope, the gamma-ray luminosity decreases relatively rapidly, forming the upper bound of the observed distribution. The gamma-ray luminosity of a general pulsar resides between these two extreme cases, reflecting the envelope composition and the magnetic inclination angle with respect to the rotation axis. The cutoff energy of the primary curvature emission is regulated below several GeV even for young pulsars because the gap thickness, and hence the acceleration electric field, is suppressed by the polarization of the produced pairs.« less

  4. Acromion Index in Korean Population and Its Relationship with Rotator Cuff Tears.

    PubMed

    Kum, Dong Ho; Kim, Jun Ho; Park, Keun Min; Lee, Eun Su; Park, Yong Bok; Yoo, Jae Chul

    2017-06-01

    Among the many causes of rotator cuff tears, scapular morphology is associated with the accelerating degenerative process of the rotator cuff. Acromion index (AI) was previously introduced and compared in two populations. We enrolled 100 Korean patients diagnosed with full-thickness rotator cuff tears by magnetic resonance imaging and intraoperative arthroscopic findings between January and December 2013. Another 100 Korean patients with an intact rotator cuff tendon identified on magnetic resonance imaging and other shoulder diseases, such as frozen shoulder and instability, were enrolled as controls. We retrospectively compared these 100 rotator cuff tear patients (mean age, 63 years) and 100 controls (mean age, 51 years) in this study. Two independent orthopedic surgeons assessed the AI on radiographs. We performed an interobserver reliability test of the AI assessment, and then compared the AI between two groups. The measurement of the AI showed excellent reliability (intraclass correlation coefficient, 0.82). The mean AI in the rotator cuff tear group was 0.68 and it was significantly different between groups ( p <0.001, 95% confidence interval). The AI was not related to tear size. Our study showed that the AI was an effective predictive factor for rotator cuff tears in a Korean population.

  5. The role of silver in the processing and properties of Bi-2212

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lang, T.; Heeb, B.; Buhl, D.

    1994-12-31

    The influence of the silver content and the oxygen partial pressure on the solidus temperature and the weight loss during melting of Bi{sub 2}Sr{sub 2}Ca{sub 1}Cu{sub 2}O{sub x} has been examined by means of DTA and TGA. By decreasing the oxygen partial pressure the solidus is lowered (e.g. {triangle}T=59{degrees}C by decreasing pO{sub 2} from 1 atm to 0.001 atm) and the weight loss is increased. The addition of silver causes two effects: (a) the solidus is further decreased (e.g. 2wt% Ag lower T{sub solidus} by up to 25{degrees}C, depending on the oxygen partial pressure), (b) the weight loss during meltingmore » is reduced. Thick films (10-20 {mu}m in thickness) with 0 and 5 wt% silver and bulk samples with 0 and 2.7 wt% silver were melt processed in flowing oxygen on a silver substrate in the DTA, allowing the observation of the melting process and a good temperature control. The critical current densities are vigorously dependent on the maximum processing temperature. The highest j{sub c} in thick films (8000 A/cm{sup 2} at 77 K, O T) was reached by melting 7{degrees}C above the solidus temperature. The silver addition shows no significant effect on the processing parameters or the superconducting properties. The highest j{sub c} for bulk samples (1 mm in thickness) was obtained by partial melting at 900{degrees}C or 880{degrees}C, depending on the silver content of the powder (0 or 2.7 wt%). The j{sub c} of the samples is slightly enhanced from 1800 A/cm{sup 2} (at 77 K, O T) to 2000 A/cm{sup 2} by the silver addition. To be able to reach at least 80% of the maximum critical current density, the temperature has to be controlled in a window of 5{degrees}C for thick films and 17{degrees}C for bulk samples.« less

  6. Engineering new properties in PbTiO3 based superlattices: compositionally broken inversion symmetry and polarization rotation

    NASA Astrophysics Data System (ADS)

    Dawber, Matthew

    2013-03-01

    In this talk I will present results on two superlattice systems which contain ultra fine layers of PbTiO3 and another perovskite material. In recent years, much work has been done on the PbTiO3/SrTiO3 system, with a focus on improper ferroelectricity and the arrangement of ferroelectric domains. Here, we consider two different partner materials for PbTiO3, each of which introduces markedly different behavior in the resulting superlattice. PbTiO3/SrRuO3 superlattices with ultra-thin SrRuO3 layers were studied both experimentally and using density functional theory. Due to the superlattice geometry, the samples show a large anisotropy in their electrical resistivity, which can be controlled by changing the thickness of the PbTiO3 layers. Therefore, along the ferroelectric direction, SrRuO3 layers can act as dielectric, rather than metallic, elements. We show that, by reducing the thickness of the PbTiO3 layers, an increasingly important effect of polarization asymmetry due to compositional inversion symmetry breaking occurs. The compositional inversion symmetry breaking is seen in this bi-color superlattice due to the combined variation of A and B site ions within the superlattice. We have also achieved an experimental enhancement of the piezoelectric response and dielectric tunability in artificially layered epitaxial PbTiO3/CaTiO3 superlattices through an engineered rotation of the polarization direction. As the relative layer thicknesses within the superlattice were changed from sample to sample we found evidence for polarization rotation in multiple x-ray diffraction measurements. Associated changes in functional properties were seen in electrical measurements and piezoforce microscopy. These results demonstrate a new approach to inducing polarization rotation under ambient conditions in an artificially layered thin film. Work supported by NSF DMR1055413

  7. Relationship between neurotoxic kynurenine metabolites and reductions in right medial prefrontal cortical thickness in major depressive disorder.

    PubMed

    Meier, Timothy B; Drevets, Wayne C; Wurfel, Brent E; Ford, Bart N; Morris, Harvey M; Victor, Teresa A; Bodurka, Jerzy; Teague, T Kent; Dantzer, Robert; Savitz, Jonathan

    2016-03-01

    Reductions in gray matter volume of the medial prefrontal cortex (mPFC), especially the rostral and subgenual anterior cingulate cortex (rACC, sgACC) are a widely reported finding in major depressive disorder (MDD). Inflammatory mediators, which are elevated in a subgroup of patients with MDD, activate the kynurenine metabolic pathway and increase production of neuroactive metabolites such as kynurenic acid (KynA), 3-hydroxykynurenine (3HK) and quinolinic acid (QA) which influence neuroplasticity. It is not known whether the alterations in brain structure and function observed in major depressive disorders are due to the direct effect of inflammatory mediators or the effects of neurotoxic kynurenine metabolites. Here, using partial posterior predictive distribution mediation analysis, we tested whether the serum concentrations of kynurenine pathway metabolites mediated reductions in cortical thickness in mPFC regions in MDD. Further, we tested whether any association between C-reactive protein (CRP) and cortical thickness would be mediated by kynurenine pathway metabolites. Seventy-three unmedicated subjects who met DSM-IV-TR criteria for MDD and 91 healthy controls (HC) completed MRI scanning using a pulse sequence optimized for tissue contrast resolution. Automated cortical parcellation was performed using the PALS-B12 Brodmann area atlas as implemented in FreeSurfer in order to compare the cortical thickness and cortical area of six PFC regions: Brodmann areas (BA) 9, 10, 11, 24, 25, and 32. Serum concentrations of kynurenine pathway metabolites were determined by high performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS) detection, while high-sensitivity CRP concentration was measured immunoturbidimetrically. Compared with HCs, the MDD group showed a reduction in cortical thickness of the right BA24 (p<0.01) and BA32 (p<0.05) regions and MDD patients with a greater number of depressive episodes displayed thinner cortex in BA32 (p<0.05). Consistent with our previous findings in an overlapping sample, the KynA/3HK ratio and the log KynA/QA were reduced in the MDD group relative to the HC group (p's<0.05) and symptoms of anhedonia were negatively correlated with log KynA/QA in the MDD group (p<0.05). Both KynA/3HK and log KynA/QA at least partially mediated the relationship between diagnosis and cortical thickness of right BA32 (p's<0.05). CRP was inversely associated with BA32 thickness (p<0.01) and KynA/3HK partially mediated the relationship between CRP and the thickness of right BA32 (p<0.05). The results raise the possibility that the relative imbalance between KynA and neurotoxic kynurenine metabolites may partially explain the reductions in mPFC thickness observed in MDD, and further that these changes are more strongly linked to the putative effects of neuroactive kynurenine metabolites than those of inflammatory mediators. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Method and apparatus for conducting variable thickness vapor deposition

    DOEpatents

    Nesslage, G.V.

    1984-08-03

    A method of vapor depositing metal on a substrate in variable thickness comprises conducting the deposition continuously without interruption to avoid formation of grain boundaries. To achieve reduced deposition in specific regions a thin wire or ribbon blocking body is placed between source and substrate to partially block vapors from depositing in the region immediately below.

  9. Origin of the Local Group satellite planes

    NASA Astrophysics Data System (ADS)

    Banik, Indranil; O'Ryan, David; Zhao, Hongsheng

    2018-04-01

    We attempt to understand the planes of satellite galaxies orbiting the Milky Way (MW) and M31 in the context of Modified Newtonian Dynamics (MOND), which implies a close MW-M31 flyby occurred ≈8 Gyr ago. Using the timing argument, we obtain MW-M31 trajectories consistent with cosmological initial conditions and present observations. We adjust the present M31 proper motion within its uncertainty in order to simulate a range of orbital geometries and closest approach distances. Treating the MW and M31 as point masses, we follow the trajectories of surrounding test particle disks, thereby mapping out the tidal debris distribution. Around each galaxy, the resulting tidal debris tends to cluster around a particular orbital pole. We find some models in which these preferred spin vectors align fairly well with those of the corresponding observed satellite planes. The radial distributions of material in the simulated satellite planes are similar to what we observe. Around the MW, our best-fitting model yields a significant fraction (0.22) of counter-rotating material, perhaps explaining why Sculptor counter-rotates within the MW satellite plane. In contrast, our model yields no counter-rotating material around M31. This is testable with proper motions of M31 satellites. In our best model, the MW disk is thickened by the flyby 7.65 Gyr ago to a root mean square height of 0.75 kpc. This is similar to the observed age and thickness of the Galactic thick disk. Thus, the MW thick disk may have formed together with the MW and M31 satellite planes during a past MW-M31 flyby.

  10. Origin of the Local Group satellite planes

    NASA Astrophysics Data System (ADS)

    Banik, Indranil; O'Ryan, David; Zhao, Hongsheng

    2018-07-01

    We attempt to understand the planes of satellite galaxies orbiting the Milky Way (MW) and M31 in the context of Modified Newtonian Dynamics, which implies a close MW-M31 flyby occurred ≈8 Gyr ago. Using the timing argument, we obtain MW-M31 trajectories consistent with cosmological initial conditions and present observations. We adjust the present M31 proper motion within its uncertainty in order to simulate a range of orbital geometries and closest approach distances. Treating the MW and M31 as point masses, we follow the trajectories of surrounding test particle discs, thereby mapping out the tidal debris distribution. Around each galaxy, the resulting tidal debris tends to cluster around a particular orbital pole. We find some models in which these preferred spin vectors align fairly well with those of the corresponding observed satellite planes. The radial distributions of material in the simulated satellite planes are similar to what we observe. Around the MW, our best-fitting model yields a significant fraction (0.22) of counter-rotating material, perhaps explaining why Sculptor counter-rotates within the MW satellite plane. In contrast, our model yields no counter-rotating material around M31. This is testable with proper motions of M31 satellites. In our best model, the MW disc is thickened by the flyby 7.65 Gyr ago to a root mean square height of 0.75 kpc. This is similar to the observed age and thickness of the Galactic thick disc. Thus, the MW thick disc may have formed together with the MW and M31 satellite planes during a past MW-M31 flyby.

  11. Non-contrast MRI diagnosis of adhesive capsulitis of the shoulder.

    PubMed

    Chi, Andrew S; Kim, John; Long, Suzanne S; Morrison, William B; Zoga, Adam C

    To investigate non-contrast MRI findings of clinical adhesive capsulitis. 31 non-contrast, non-arthrographic, shoulder MRIs were evaluated for coracohumeral ligament thickness, rotator interval infiltration, and axillary recess thickening/edema. In detection of adhesive capsulitis, sensitivity is 76.7% and specificity is 53.3% for coracohumeral ligament thickening, sensitivity is 66.7% and specificity is 55.2% for coracohumeral ligament thickening and rotator interval infiltration, and sensitivity is 23.3% and specificity is 86.7% for coracohumeral ligament thickening, rotator interval infiltration, and axillary recess thickening/edema. Adhesive capsulitis can be accurately diagnosed on non-contrast MRI shoulder examinations with appropriate clinical criteria without direct MR arthrography. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. A high yield neutron target

    NASA Technical Reports Server (NTRS)

    Alger, D. L.; Steinberg, R.; Weisenbach, P.

    1974-01-01

    Target, in cylinder form, rotates rapidly in front of beam. Titanium tritide film is much thicker than range of accelerated deutron. Sputtering electrode permits full use of thick film. Stream of high-velocity coolant provides efficient transfer of heat from target.

  13. The evolution of rotating stars. III - Predicted surface rotation velocities for stars which conserve total angular momentum

    NASA Technical Reports Server (NTRS)

    Endal, A. S.; Sofia, S.

    1979-01-01

    Predicted surface rotation velocities for Population I stars at 10, 7, 5, 3, and 1.5 solar masses are presented. The surface velocities were computed for angular momentum with no radial redistribution, complete redistribution, and partial redistribution as predicted by consideration of circulation currents in rotating stars. Near the main sequence, rotational effects can reduce the moment of inertia of a star, so nonrotating models underestimate the expected velocities for evolving stars. On the red giant branch, angular momentum redistribution reduces the surface velocity by a factor of 2 or more, relative to the velocity expected for no radial redistribution. This removes the discrepancy between predicted and observed rotation rates for the K giants and makes it unlikely that these stars lose significant amounts of angular momentum by stellar winds. Calculations indicate that improved observations of the red giants in the Hyades cluster can be used to determine how angular momentum is redistributed by convection

  14. Single perforator greater saphenous neuro-veno-fasciocutaneous propeller flaps for lower extremity reconstructions.

    PubMed

    Zhong, Wanrun; Lu, Shengdi; Wang, Chunyang; Wen, Gen; Han, Pei; Chai, Yimin

    2017-07-01

    The lack of soft tissue that is available for medial leg and foot defect reconstructions presents a challenge for plastic surgeons. The saphenous neurofasciocutaneous perforator flap application presents an effective alternative to local flap transfers. However, the venous flow and pedicle twisting problems are still disputed. Here, we present our experiences with modified cutaneous pedicles with a single perforator pedicle, which improves the venous flow and the pedicle twisting problem. This study was conducted from June 2007 through September 2011, and a total of 15 patients with lower medial leg and foot defects were included. There were 11 men and four women. An asymmetric 'propeller' flap was planned around a perforator that was adjacent to the defects, which was preoperatively confirmed by Doppler. The perforator was sufficiently dissociated to allow for the flap to be turned towards the defects. We preserved some distal skin and subcutaneous tissue from the short side of the 'propeller' to cover some donor site regions, and other regions were covered with split thickness skin grafts. The follow-up period ranged from 3 to 12 months. An infection occurred in one case. Partial flap necrosis was noted in two cases. The other 12 flaps completely survived and matched the recipient sites with regard to colour, texture and thickness. The single perforator greater saphenous neuro-veno-fasciocutaneous propeller flap is an effective solution for medial leg and foot defects, and it has a large rotation arc and a satisfactory aesthetic result. © 2015 Royal Australasian College of Surgeons.

  15. The age of the galactic disk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandage, A.

    The galactic disk is a dissipative structure and must, therefore be younger than the halo if galaxy formation generally proceeds by collapse. Just how much younger the oldest stars in the galactic disk are than the oldest halo stars remains an open question. A fast collapse (on a time scale no longer than the rotation period of the extended protogalaxy) permits an age gap of the order of approximately 10 to the 9th power years. A slow collapse, governed by the cooling rate of the partially pressure supported falling gas that formed into what is now the thick stellar disk,more » permits a longer age gap, claimed by some to be as long as 6 Gyr. Early methods of age dating the oldest components of the disk contain implicit assumptions concerning the details of the age-metallicity relation for stars in the solar neighborhood. The discovery that this relation for open clusters outside the solar circle is different that in the solar neighborhood (Geisler 1987), complicates the earlier arguments. The oldest stars in the galactic disk are at least as old as NGC 188. The new data by Janes on NGC 6791, shown first at this conference, suggest a disk age of at least 12.5 Gyr, as do data near the main sequence termination point of metal rich, high proper motion stars of low orbital eccentricity. Hence, a case can still be made that the oldest part of the galactic thick disk is similar in age to the halo globular clusters, if their ages are the same as 47 Tuc.« less

  16. The age of the galactic disk

    NASA Technical Reports Server (NTRS)

    Sandage, Allan

    1988-01-01

    The galactic disk is a dissipative structure and must, therefore be younger than the halo if galaxy formation generally proceeds by collapse. Just how much younger the oldest stars in the galactic disk are than the oldest halo stars remains an open question. A fast collapse (on a time scale no longer than the rotation period of the extended protogalaxy) permits an age gap of the order of approximately 10 to the 9th power years. A slow collapse, governed by the cooling rate of the partially pressure supported falling gas that formed into what is now the thick stellar disk, permits a longer age gap, claimed by some to be as long as 6 Gyr. Early methods of age dating the oldest components of the disk contain implicit assumptions concerning the details of the age-metallicity relation for stars in the solar neighborhood. The discovery that this relation for open clusters outside the solar circle is different that in the solar neighborhood (Geisler 1987), complicates the earlier arguments. The oldest stars in the galactic disk are at least as old as NGC 188. The new data by Janes on NGC 6791, shown first at this conference, suggest a disk age of at least 12.5 Gyr, as do data near the main sequence termination point of metal rich, high proper motion stars of low orbital eccentricity. Hence, a case can still be made that the oldest part of the galactic thick disk is similar in age to the halo globular clusters, if their ages are the same as 47 Tuc.

  17. Functionality of Immunoglobulin G and Immunoglobulin M Antibody Physisorbed on Cellulosic Films

    PubMed Central

    Huang, Ziwei; Raghuwanshi, Vikram Singh; Garnier, Gil

    2017-01-01

    The functionality and aging mechanism of antibodies physisorbed onto cellulosic films was investigated. Blood grouping antibodies immunoglobulin G (IgG) and immunoglobulin M (IgM) were adsorbed onto smooth cellulose acetate (CAF) and regenerated cellulose (RCF) films. Cellulose films and adsorbed IgG layers were characterized at the air and liquid interface by X-ray and neutron reflectivity (NR), respectively. Cellulose film 208 Å thick (in air) swell to 386 Å once equilibrated in water. IgG adsorbs from solution onto cellulose as a partial layer 62 Å thick. IgG and IgM antibodies were adsorbed onto cellulose and cellulose acetate films, air dried, and aged at room temperature for periods up to 20 days. Antibody functionality and surface hydrophobicity were measured everyday with the size of red blood cell (RBC) agglutinates (using RBC specific to IgG/IgM) and the water droplet contact angle, respectively. The functionality of the aged IgG/IgM decreases faster if physisorbed on cellulose than on cellulose acetate and correlates to surface hydrophobicity. IgG physisorbed on RCF or CAF age better and remain functional longer than physisorbed IgM. We found a correlation between antibody stability and hydrogen bond formation ability of the system, evaluated from antibody carbonyl concentration and cellulosic surface hydroxyl concentration. Antibody physisorbs on cellulose by weak dipole forces and hydrogen bonds. Strong hydrogen bonding contributes to the physisorption of antibody on cellulose into a non-functional configuration in which the molecule relaxes by rotation of hydophobic groups toward the air interface. PMID:28770196

  18. [MRI of the rotator cuff: evaluation of a new symptomatologic classification].

    PubMed

    Tavernier, T; Walch, G; Noël, E; Lapra, C; Bochu, M

    1995-05-01

    The different classifications use for the rotator cuff pathology seem to be incomplete. We propose a new classification with many advantages: 1) Differentiate the tendinopathy between less serious (grade 2A) and serious (grade 2B). 2) Recognize the intra-tendinous cleavage of the infra-spinatus associated with complete tear of the supra-spinatus. 3) Differentiate partial and complete tears of the supra-spinatus. We established this classification after a retrospective study of 42 patients operated on for a rotator cuff pathology. Every case had had a preoperative MRI. This classification is simple, reliable, especially for the associated intra tendinous cleavage.

  19. Coolant side heat transfer with rotation: User manual for 3D-TEACH with rotation

    NASA Technical Reports Server (NTRS)

    Syed, S. A.; James, R. H.

    1989-01-01

    This program solves the governing transport equations in Reynolds average form for the flow of a 3-D, steady state, viscous, heat conducting, multiple species, single phase, Newtonian fluid with combustion. The governing partial differential equations are solved in physical variables in either a Cartesian or cylindrical coordinate system. The effects of rotation on the momentum and enthalpy calculations modeled in Cartesian coordinates are examined. The flow of the fluid should be confined and subsonic with a maximum Mach number no larger than 0.5. This manual describes the operating procedures and input details for executing a 3D-TEACH computation.

  20. Bracing can partially limit tibial rotation during stressful activities after anterior crucial ligament reconstruction with a hamstring graft.

    PubMed

    Giotis, D; Paschos, N K; Zampeli, F; Pappas, E; Mitsionis, G; Georgoulis, A D

    2016-09-01

    Hamstring graft has substantial differences with BPTB graft regarding initial mechanical strength, healing sequence, and vascularization, which may imply that a different approach during rehabilitation period is required. The purpose of this study was to investigate the influence of knee bracing on tibial rotation in ACL-reconstructed patients with a hamstring autograft during high loading activities. The hypothesis was that there would be a decrease in tibial rotation in the ACL-reconstructed braced knee as compared to the unbraced knee. Twenty male patients having undergone unilateral ACL reconstruction with a semitendinosus/gracilis autograft were assessed. Kinematic data were collected with an eight-camera optoelectronic system during two stressful tasks: (1) descending from a stair and subsequent pivoting; and (2) landing from a platform and subsequent pivoting. In each patient, three different experimental conditions were evaluated: (A) wearing a prophylactic brace (braced condition); (B) wearing a patellofemoral brace (sleeved condition); (C) without brace (unbraced condition). The intact knee without brace served as a control. Tibial rotation was significantly lower in the intact knee compared to all three conditions of the ACL-reconstructed knee (P≤0.01 for both tasks). Presence of a brace or sleeve resulted in lower tibial rotation than in the unbraced condition (p=0.003 for descending/pivot and P=0.0004 for landing/pivot). The braced condition resulted in lower rotation than the sleeved condition for descending/pivoting (P=0.031) while no differences were found for landing/pivoting (P=0.230). Knee bracing limited the excessive tibial rotation during pivoting under high loading activities in ACL-reconstructed knees with a hamstring graft. This partial restoration of normal kinematics may have a potential beneficial effect in patients recovering from ACL reconstruction with a hamstring autograft. Level III, case-control therapeutic study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Stowage and Deployment of Slit Tube Booms

    NASA Technical Reports Server (NTRS)

    Adams, Larry (Inventor); Turse, Dana (Inventor); Richardson, Doug (Inventor)

    2016-01-01

    A system comprising a boom having a first end, a longitudinal length, and a slit that extends along the longitudinal length of the boom; a drum having an elliptic cross section and a longitudinal length; an attachment mechanism coupled with the first end of the boom and the drum such that the boom and the drum are substantially perpendicular relative to one another; an inner shaft having a longitudinal length, the inner shaft disposed within the drum, the longitudinal length of the inner shaft is aligned substantially parallel with the longitudinal length of the drum, the inner shaft at least partially rotatable relative to the drum, and the inner shaft is at least partially rotatable with the drum; and at least two cords coupled with the inner shaft and portions of the boom near the first end of the boom.

  2. PARTIAL ARTICULAR SUPRASPINATUS TENDON AVULSION (PASTA) LESION. CURRENT CONCEPTS IN REHABILITATION

    PubMed Central

    2016-01-01

    ABSTRACT Rotator cuff pathology can contribute to shoulder pain and may affect the performance of sport activities, work, and activities of daily living. The partial articular supraspinatus tendon avulsion (PASTA) lesion represents a very common type of rotator cuff pathology seen in rehabilitation. When conservative treatment fails, surgery is generally required. Success of recovery depends on several factors, including: repair techniques, healing process related to timing, rehabilitation programs, and patient compliance with home exercises. To date, most treatment modalities and rehabilitation programs are based on clinical experience rather than scientific evidence. Therefore, the purpose of this clinical commentary is to provide an overview on the PASTA lesion, discuss the common treatment approaches adopted to date and to propose a rehabilitation program based on the available scientific evidence. Level of Evidence 5 PMID:27274431

  3. The treatment of sulphur mustard burns with laser debridement.

    PubMed

    Evison, D; Brown, R F R; Rice, P

    2006-01-01

    The chemical warfare agent, sulphur mustard (SM), is a potent blistering agent in man. Skin exposure can produce partial-thickness burns which take up to three months to heal. The aim of this study was to investigate the use of early laser ablation as a means of accelerating this exceptionally slow rate of healing. Four circular partial-thickness SM burns were induced on the dorsum of nine large white pigs (under general anaesthesia). At 72 h post-exposure, three burns per animal were ablated with a single pass of an UltraPulse 5000C CO(2) laser, at a fluence of 5-6 J cm(-2). All the burns were dressed with silver sulphadiazine and a semi-occlusive dressing. At one, two and three weeks post-surgery three animals were culled and all lesions excised for histological analysis. Burn depth was confirmed and measurements of the radii of regenerative epithelium were performed allowing the area of the zone of re-epithelialisation in each lesion to be calculated. Laser-treated lesions showed a significant increase (350%) in healing rates compared to controls (p<0.005). At two weeks, the laser-treated sites were 95% healed in comparison with control sites (28% healed). These data suggest that laser ablation may be effective in the treatment of partial-thickness SM-induced skin injury.

  4. Effects of artificially produced defects on film thickness distribution in sliding EHD point contacts

    NASA Technical Reports Server (NTRS)

    Cusano, C.; Wedeven, L. D.

    1981-01-01

    The effects of artificially produced dents and grooves on the elastohydrodynamic (EHD) film thickness profile in a sliding point contact were investigated by means of optical interferometry. The defects, formed on the surface of a highly polished ball, were held stationary at various locations within and in the vicinity of the contact region while the disk was rotating. It is shown that the defects, having a geometry similar to what can be expected in practice, can dramatically change the film thickness which exists when no defects are present in or near the contact. This change in film thickness is mainly a function of the position of the defects in the inlet region, the geometry of the defects, the orientation of the defects in the case of grooves, and the depth of the defect relative to the central film thickness.

  5. Stereotype susceptibility narrows the gender gap in imagined self-rotation performance.

    PubMed

    Wraga, Maryjane; Duncan, Lauren; Jacobs, Emily C; Helt, Molly; Church, Jessica

    2006-10-01

    Three studies examined the impact of stereotype messages on men's and women's performance of a mental rotation task involving imagined self-rotations. Experiment 1 established baseline differences between men and women; women made 12% more errors than did men. Experiment 2 found that exposure to a positive stereotype message enhanced women's performance in comparison with that of another group of women who received neutral information. In Experiment 3, men who were exposed to the same stereotype message emphasizing a female advantage made more errors than did male controls, and the magnitude of error was similar to that for women from Experiment 1. The results suggest that the gender gap in mental rotation performance is partially caused by experiential factors, particularly those induced by sociocultural stereotypes.

  6. Nonlinear model of a rotating hub-beams structure: Equations of motion

    NASA Astrophysics Data System (ADS)

    Warminski, Jerzy

    2018-01-01

    Dynamics of a rotating structure composed of a rigid hub and flexible beams is presented in the paper. A nonlinear model of a beam takes into account bending, extension and nonlinear curvature. The influence of geometric nonlinearity and nonconstant angular velocity on dynamics of the rotating structure is presented. The exact equations of motion and associated boundary conditions are derived on the basis of the Hamilton's principle. The simplification of the exact nonlinear mathematical model is proposed taking into account the second order approximation. The reduced partial differential equations of motion together with associated boundary conditions can be used to study natural or forced vibrations of a rotating structure considering constant or nonconstant angular speed of a rigid hub and an arbitrary number of flexible blades.

  7. Bubble mass center and fluid feedback force fluctuations activated by constant lateral impulse with variable thrust

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Long, Y. T.

    1995-01-01

    Sloshing dynamics within a partially filled rotating dewar of superfluid helium 2 are investigated in response to constant lateral impulse with variable thrust. The study, including how the rotating bubble of superfluid helium 2 reacts to the constant impulse with variable time period of thrust action in microgravity, how amplitudes of bubble mass center fluctuates with growth and decay of disturbances, and how fluid feedback forces fluctuates in activating on the rotating dewar through the dynamics of sloshing waves are investigated. The numerical computation of sloshing dynamics is based on the non-inertial frame spacecraft bound coordinate with lateral impulses actuating on the rotating dewar in both inertial and non-inertial frames of thrust. Results of the simulations are illustrated.

  8. Development of rotating magnetic field coil system in the HIST spherical torus device

    NASA Astrophysics Data System (ADS)

    Yoshikawa, T.; Kikuchi, Y.; Yamada, S.; Hashimoto, S.; Nishioka, T.; Fukumoto, N.; Nagata, M.

    2007-11-01

    Coaxial Helicity Injection (CHI) is one of most attractive methods to achieve non-inductive current drive in spherical torus devices. The current drive mechanism of CHI relies on MHD relaxation process of rotating kink behavior [1], so that there is a possibility to control the CHI by using an externally applied rotating magnetic field (RMF). We have recently started to develop a RMF coil system in the HIST spherical torus device. Eight coils are located above and below the midplane at four toroidal locations so that the RMF is resonant with n = 1 rotating kink mode driven by the CHI. In addition, the RMF coil set is installed inside a flux conserver of 5 mm thickness (cut-off frequency ˜ 170 Hz) so that the RMF penetrates into the plasma. The coil winding is made of 20 turns of enameled copper circular wires (1.5 mm^2 conductor cross section), covered with a thin stainless steal case of 0.5 mm thickness (cut-off frequency ˜ 710 kHz). The RMF system is driven by an IGBT inverter power supply (nominal current: 1 kA, nominal voltage: 1 kV) with an operating frequency band from 10 kHz to 30 kHz. The estimated amplitude of RMF neglecting effects of image current at the flux conserver is a few tens Gauss at around the magnetic axis. A preliminary experimental result will be shown in the conference. [1] M. Nagata, et al., Physics of Plasmas 10, 2932 (2003).

  9. Uniform analytic approximation of Wigner rotation matrices

    NASA Astrophysics Data System (ADS)

    Hoffmann, Scott E.

    2018-02-01

    We derive the leading asymptotic approximation, for low angle θ, of the Wigner rotation matrix elements, dm1m2 j(θ ) , uniform in j, m1, and m2. The result is in terms of a Bessel function of integer order. We numerically investigate the error for a variety of cases and find that the approximation can be useful over a significant range of angles. This approximation has application in the partial wave analysis of wavepacket scattering.

  10. Identification and Characterization of Sites Where Persistent Atrial Fibrillation Is Terminated by Localized Ablation.

    PubMed

    Zaman, Junaid A B; Sauer, William H; Alhusseini, Mahmood I; Baykaner, Tina; Borne, Ryan T; Kowalewski, Christopher A B; Busch, Sonia; Zei, Paul C; Park, Shirley; Viswanathan, Mohan N; Wang, Paul J; Brachmann, Johannes; Krummen, David E; Miller, John M; Rappel, Wouter Jan; Narayan, Sanjiv M; Peters, Nicholas S

    2018-01-01

    The mechanisms by which persistent atrial fibrillation (AF) terminates via localized ablation are not well understood. To address the hypothesis that sites where localized ablation terminates persistent AF have characteristics identifiable with activation mapping during AF, we systematically examined activation patterns acquired only in cases of unequivocal termination by ablation. We recruited 57 patients with persistent AF undergoing ablation, in whom localized ablation terminated AF to sinus rhythm or organized tachycardia. For each site, we performed an offline analysis of unprocessed unipolar electrograms collected during AF from multipolar basket catheters using the maximum -dV/dt assignment to construct isochronal activation maps for multiple cycles. Additional computational modeling and phase analysis were used to study mechanisms of map variability. At all sites of AF termination, localized repetitive activation patterns were observed. Partial rotational circuits were observed in 26 of 57 (46%) cases, focal patterns in 19 of 57 (33%), and complete rotational activity in 12 of 57 (21%) cases. In computer simulations, incomplete segments of partial rotations coincided with areas of slow conduction characterized by complex, multicomponent electrograms, and variations in assigning activation times at such sites substantially altered mapped mechanisms. Local activation mapping at sites of termination of persistent AF showed repetitive patterns of rotational or focal activity. In computer simulations, complete rotational activation sequence was observed but was sensitive to assignment of activation timing particularly in segments of slow conduction. The observed phenomena of repetitive localized activation and the mechanism by which local ablation terminates putative AF drivers require further investigation. © 2018 American Heart Association, Inc.

  11. Neovascularization prevalence in the supraspinatus of patients with rotator cuff tendinopathy.

    PubMed

    Kardouni, Joseph R; Seitz, Amee L; Walsworth, Matthew K; Michener, Lori A

    2013-11-01

    A high prevalence of neovascularity in lower extremity tendinopathies has been reported. Neovascularity in those with rotator cuff tendinopathy exclusively has not been examined. The objective was to determine the prevalence of neovascularization in patients with rotator cuff tendinopathy compared with asymptomatic controls. Single-blind cross-sectional study. Research laboratory. Participants (n = 40; age = 44.9 years, 23-62 years; 20 females) with rotator cuff tendinopathy (n = 20) but without full-thickness rotator cuff tears, and asymptomatic controls that were age, gender, and hand dominance matched (n = 20) to the patients. The participants laying in supine had their shoulder positioned in internal rotation and extension. Ultrasound images were collected of the supraspinatus tendon and subacromial bursae in the transverse and longitudinal planes using a linear transducer in color Doppler mode. Images were assessed for neovascularization by 2 trained raters who were blinded to group (rotator cuff tendinopathy or asymptomatic group). No statistically significant difference in neovascularization was identified between participants with and without rotator cuff tendinopathy (χ = 0.13, df = 1, P = 0.72). Neovascularization was identified in 6 of 20 patients with rotator cuff tendinopathy (30%) and 5 of 20 asymptomatic control participants (25%). The authors found no differences in neovascularization rate in patients with rotator cuff tendinopathy (30%) and asymptomatic controls (25%). The study indicates that neovascularization is not related to presence of symptomatic tendinopathy in those with rotator cuff tendinopathy. Neovascularization may not be a relevant sonographic finding to aid the clinical assessment of those with rotator cuff tendinopathy.

  12. Finite plate thickness effects on the Rayleigh-Taylor instability in elastic-plastic materials

    NASA Astrophysics Data System (ADS)

    Polavarapu, Rinosh; Banerjee, Arindam

    2017-11-01

    The majority of theoretical studies have tackled the Rayleigh-Taylor instability (RTI) problem in solids using an infinitely thick plate. Recent theoretical studies by Piriz et al. (PRE 95, 053108, 2017) have explored finite thickness effects. We seek to validate this recent theoretical estimate experimentally using our rotating wheel RTI experiment in an accelerated elastic-plastic material. The test section consists of a container filled with air and mayonnaise (a non-Newtonian emulsion) with an initial perturbation between two materials. The plate thickness effects are studied by varying the depth of the soft-solid. A set of experiments is run by employing different initial conditions with different container dimensions. Additionally, the effect of acceleration rate (driving pressure rise time) on the instability threshold with reference to the finite thickness will also be inspected. Furthermore, the experimental results are compared to the analytical strength models related to finite thickness effects on RTI. Authors acknowledge financial support from DOE-SSAA Grant # DE-NA0003195 and LANL subcontract #370333.

  13. Use of a copolymer dressing on superficial and partial-thickness burns in a paediatric population.

    PubMed

    Everett, M; Massand, S; Davis, W; Burkey, B; Glat, P M

    2015-07-01

    Despite extensive research into the treatment of partial-thickness burns, to date there has not been the emergence of a preeminent modality. This pilot study, the first such study to be performed in a burn unit in the US, was designed to evaluate the efficacy and outcomes of the application of copolymer dressing (Suprathel; PolyMedics Innovations Corporation, Stuttgart, Germany) for both superficial and deeper partial-thickness burns. The copolymer dressing was used as a primary wound dressing to treat superficial and deep partial-thickness burns (average 5% total body surface area) in paediatric patients. Burns were debrided within 24 hours, at bedside, in the burn unit or in the operating room. The copolymer dressing was then applied directly to the wound and covered with a non-adherent second layer and an absorptive outer dressing. After discharge, patients were seen every 5-7 days until healed. Parameters evaluated included average hospital length of stay, average number of intravenous doses of narcotics administered, pain score at first follow-up visit, average time to complete re epithelialisation, incidence of burn wound infection, and patient/parent satisfaction on a 4-point scale. We also evaluated our experience with the dressing. Data were evaluated retrospectively under an Investigational Review Board approved protocol. Of the 17 patients assessed the average hospital length of stay was 1.4 days during which the average number of intravenous narcotic doses administered before copolymer dressing application was 1.5 and after was 0.1 doses. At the first follow-up visit, average pain score was 1.2 on a 10-point scale and the average time to re epithelialisation was 9.5 days. There was no incidence of burn wound infection. Patient/parent satisfaction was average of 3.66 on a 4-point scale. The staff had found that the self-adherence and elasticity of the dressing made it easy to apply and stay adherent, especially in areas of difficult contour. There were no readmissions for further debridement or skin grafting. Our experience shows that patients may be discharged shortly after the application of the copolymer dressing, with manageable pain scores and ease of use as determined by the caretakers high satisfaction. This new, fully synthetic copolymer dressing is easy to apply, does not require any additional antimicrobial coverage and may be used to successfully manage deeper partial-thickness burns, donor sites or burns in areas of contour, where many other dressings might not be considered or be appropriate. None declared.

  14. Effects of oriental sweet gum storax on porcine wound healing.

    PubMed

    Ocsel, Hakan; Teke, Zafer; Sacar, Mustafa; Kabay, Burhan; Duzcan, S Ender; Kara, Inci Gokalan

    2012-08-01

    The objective of the present study was to assess the effects of oriental sweet gum (Liquidambar orientalis Mill.) storax on partial-thickness and full-thickness wounds compared to conventional wound dressings in a porcine model. Six young Yorkshire pigs were used. Sixteen square excisional wounds measuring 3 × 3 cm were performed per animal. The wounds were allocated to one of the four treatment modalities: storax, hydrocolloid dressing, silver sulfadiazine, and control groups. Partial-thickness wounds were created in two pigs, and tissue samples were harvested on days 4 and 8, respectively. Full-thickness wounds were created in four pigs, and tissue samples were taken on days 4, 8, 14, and 21, respectively. Histologically, all wounds were examined for re-epithelialization and granulation tissue formation. Tissue hydroxyproline content and wound contraction areas were measured. In storax-applied group, there was a greater depth of granulation tissue at 4 and 8 days compared to all other groups (p < .0125), and there was a faster re-epithelialization at 21 days compared to both hydrocolloid dressing and control groups in full-thickness wounds (p < .0125). Tissue hydroxyproline content and wound contraction did not differ significantly between the groups. The results of this study indicate that topical application of storax enhanced both re-epithelialization and granulation tissue formation in full-thickness wounds. Further studies are indicated in this important area of wound healing research to evaluate the clinical efficacy of this storax and search for the mechanisms that explain its effects.

  15. Enhancing Friction Stir Weldability of 6061-T6 Al and AZ31B Mg Alloys Assisted by External Non-rotational Shoulder

    NASA Astrophysics Data System (ADS)

    Ji, Shude; Huang, Ruofei; Meng, Xiangchen; Zhang, Liguo; Huang, Yongxian

    2017-05-01

    In order to increase cooling rate and then reduce the amounts of intermetallic compounds, external non-rotational shoulder tool system derived from traditional tool in friction stir welding was used to join dissimilar Al and Mg alloys. In this study, based on the external non-rotational shoulder, the weldability of Al and Mg alloys was significantly improved. The non-rotational shoulder tool is propitious to make more materials into weld, increase cooling rate and then reduce material adhesion of rotational pin, obtaining sound joint with smaller flashes and smooth surface. Importantly, the thickness of intermetallic compounds layer is reduced compared with traditional tool. Meanwhile, hardness values of dissimilar joint present uneven distribution, resulting from complex intercalated structures in nugget zone (NZ) featured by intermetallic compound layers and fine recrystallized Mg and Al grains. Compared with traditional tool, non-rotational shoulder is beneficial to higher tensile properties of joint. Due to the intermetallic compound layer formed in the interface of Al-Mg, the welding joint easily fractures at the NZ, presenting the typical brittle fracture mode.

  16. Rotational stabilization of the resistive wall modes in tokamaks with a ferritic wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pustovitov, V. D.; National Research Nuclear University “MEPhI,” Kashirskoe sh. 31, Moscow 115409; Yanovskiy, V. V.

    The dynamics of the rotating resistive wall modes (RWMs) is analyzed in the presence of a uniform ferromagnetic resistive wall with μ{sup ^}≡μ/μ{sub 0}≤4 (μ is the wall magnetic permeability, and μ{sub 0} is the vacuum one). This mimics a possible arrangement in ITER with ferromagnetic steel in test blanket modules or in future experiments in JT-60SA tokamak [Y. Kamada, P. Barabaschi, S. Ishida, the JT-60SA Team, and JT-60SA Research Plan Contributors, Nucl. Fusion 53, 104010 (2013)]. The earlier studies predict that such a wall must provide a destabilizing influence on the plasma by reducing the beta limit and increasingmore » the growth rates, compared to the reference case with μ{sup ^}=1. This is true for the locked modes, but the presented results show that the mode rotation changes the tendency to the opposite. At μ{sup ^}>1, the rotational stabilization related to the energy sink in the wall becomes even stronger than at μ{sup ^}=1, and this “external” effect develops at lower rotation frequency, estimated as several kHz at realistic conditions. The study is based on the cylindrical dispersion relation valid for arbitrary growth rates and frequencies. This relation is solved numerically, and the solutions are compared with analytical dependences obtained for slow (s/d{sub w}≫1) and fast (s/d{sub w}≪1) “ferromagnetic” rotating RWMs, where s is the skin depth and d{sub w} is the wall thickness. It is found that the standard thin-wall modeling becomes progressively less reliable at larger μ{sup ^}, and the wall should be treated as magnetically thick. The analysis is performed assuming only a linear plasma response to external perturbations without constraints on the plasma current and pressure profiles.« less

  17. Magnetic anisotropies and rotational hysteresis in Ni81Fe19/Fe50Mn50 films: A study by torque magnetometry and anisotropic magnetoresistance

    NASA Astrophysics Data System (ADS)

    da Silva, O. E.; de Siqueira, J. V.; Kern, P. R.; Garcia, W. J. S.; Beck, F.; Rigue, J. N.; Carara, M.

    2018-04-01

    Exchange bias properties of NiFe/FeMn thin films have been investigated through X-ray diffraction, hysteresis loops, angular measurements of anisotropic magnetoresistance (AMR) and magnetic torque. As first predicted by Meiklejohn and Bean we found a decrease on the bias field as the NiFe layer thickness increases. However such reduction is not as strong as expected and it was attributed to the increase on the number of uncompensed antiferromagnetic spins resulting from the increase on the number of FeMn grains at the interface as the thickness of the NiFe layer is increased. The angular evolution of AMR and the magnetic torque were calculated and compared to the experimental ones using the minimization of the free magnetic energy and finding the magnetization equilibrium angle. The free energy, for each grain of the polycrystalline sample, is composed by the following terms: Zeeman, uniaxial, unidirectional and the rotatable energies. While from the AMR curves we obtain stable anisotropy fields independently on the measuring fields, from the torque curves we obtain increasing values of the uniaxial and rotatable fields, as the measuring field is increased. These results were attributed to the physical origin and sensitivity of the two different techniques. Magnetoresistance is mainly sensitive to the inner portion of the ferromagnetic layer, and the torque brings out information of the whole ferromagnetic layer including the interface of the layers. In this way, we believe that the increase in the uniaxial and rotatable values were due to an increase on the volume of the ferromagnetic layer, near the interfaces, which is made to rotate with the measuring field. Studying the rotational hysteresis by both techniques allows to separately obtain the contributions coming from the inner portion of ferromagnetic layer and from the interface.

  18. STRONG DEPENDENCE OF THE INNER EDGE OF THE HABITABLE ZONE ON PLANETARY ROTATION RATE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Jun; Abbot, Dorian S.; Boué, Gwenaël

    2014-05-20

    Planetary rotation rate is a key parameter in determining atmospheric circulation and hence the spatial pattern of clouds. Since clouds can exert a dominant control on planetary radiation balance, rotation rate could be critical for determining the mean planetary climate. Here we investigate this idea using a three-dimensional general circulation model with a sophisticated cloud scheme. We find that slowly rotating planets (like Venus) can maintain an Earth-like climate at nearly twice the stellar flux as rapidly rotating planets (like Earth). This suggests that many exoplanets previously believed to be too hot may actually be habitable, depending on their rotationmore » rate. The explanation for this behavior is that slowly rotating planets have a weak Coriolis force and long daytime illumination, which promotes strong convergence and convection in the substellar region. This produces a large area of optically thick clouds, which greatly increases the planetary albedo. In contrast, on rapidly rotating planets a much narrower belt of clouds form in the deep tropics, leading to a relatively low albedo. A particularly striking example of the importance of rotation rate suggested by our simulations is that a planet with modern Earth's atmosphere, in Venus' orbit, and with modern Venus' (slow) rotation rate would be habitable. This would imply that if Venus went through a runaway greenhouse, it had a higher rotation rate at that time.« less

  19. The local rotation curve of the Milky Way based on SEGUE and RAVE data

    NASA Astrophysics Data System (ADS)

    Sysoliatina, K.; Just, A.; Golubov, O.; Parker, Q. A.; Grebel, E. K.; Kordopatis, G.; Zwitter, T.; Bland-Hawthorn, J.; Gibson, B. K.; Kunder, A.; Munari, U.; Navarro, J.; Reid, W.; Seabroke, G.; Steinmetz, M.; Watson, F.

    2018-06-01

    Aims: We construct the rotation curve of the Milky Way in the extended solar neighbourhood using a sample of Sloan Extension for Galactic Understanding and Exploration (SEGUE) G-dwarfs. We investigate the rotation curve shape for the presence of any peculiarities just outside the solar radius as has been reported by some authors. Methods: Using the modified Strömberg relation and the most recent data from the RAdial Velocity Experiment (RAVE), we determine the solar peculiar velocity and the radial scale lengths for the three populations of different metallicities representing the Galactic thin disc. Subsequently, with the same binning in metallicity for the SEGUE G-dwarfs, we construct the rotation curve for a range of Galactocentric distances from 7 to 10 kpc. We approach this problem in a framework of classical Jeans analysis and derive the circular velocity by correcting the mean tangential velocity for the asymmetric drift in each distance bin. With SEGUE data we also calculate the radial scale length of the thick disc taking as known the derived peculiar motion of the Sun and the slope of the rotation curve. Results: The tangential component of the solar peculiar velocity is found to be V ⊙ = 4.47 ± 0.8 km s-1 and the corresponding scale lengths from the RAVE data are Rd(0 < [Fe/H] < 0.2) = 2.07 ± 0.2 kpc, Rd(-0.2 < [Fe/H] < 0) = 2.28 ± 0.26 kpc and Rd(-0.5 < [Fe/H] <-0.2) = 3.05 ± 0.43 kpc. In terms of the asymmetric drift, the thin disc SEGUE stars are demonstrated to have dynamics similar to the thin disc RAVE stars, therefore the scale lengths calculated from the SEGUE sample have close values: Rd(0 < [Fe/H] < 0.2) = 1.91 ± 0.23 kpc, Rd(-0.2 < [Fe/H] < 0) = 2.51 ± 0.25 kpc and Rd(-0.5 < [Fe/H] <-0.2) = 3.55 ± 0.42 kpc. The rotation curve constructed through SEGUE G-dwarfs appears to be smooth in the selected radial range 7 kpc < R < 10 kpc. The inferred power law index of the rotation curve is 0.033 ± 0.034, which corresponds to a local slope of dV c/dR = 0.98 ± 1 km s-1 kpc-1. The radial scale length of the thick disc is 2.05 kpc with no essential dependence on metallicity. Conclusions: The local kinematics of the thin disc rotation as determined in the framework of our new careful analysis does not favour the presence of a massive overdensity ring just outside the solar radius. We also find values for solar peculiar motion, radial scale lengths of thick disc, and three thin disc populations of different metallicities as a side result of this work.

  20. The flow of a thin liquid film on a stationary and rotating disk. I - Experimental analysis and flow visualization

    NASA Technical Reports Server (NTRS)

    Thomas, S.; Faghri, A.; Hankey, W.

    1990-01-01

    The mean thickness of a thin liquid film of deionized water with a free surface on a stationary and rotating horizontal disk has been measured with a nonobtrusive capacitance technique. The measurements were taken when the rotational speed was 0-300 RPM and the flow rate was 7.0-15.0 LPM. A flow visualization study of the thin film was also performed to determine the characteristics of the waves on the free surface. When the disk was stationary, a circular hydraulic jump was present on the disk. Surface waves were found in the supercritical and subcritical regions at all flow rates studied. When the rotational speed of the disk is low, a standing wave at the edge of the disk was present. As the rotational speed increased, the surface waves changed from the wavy-laminar region to a region in which the waves ran nearly radially across the disk on top of a thin substrate of fluid.

  1. Analysis of Hydrodynamics and Heat Transfer in a Thin Liquid Film Flowing over a Rotating Disk by Integral Method

    NASA Technical Reports Server (NTRS)

    Basu, S.; Cetegen, B. M.

    2005-01-01

    An integral analysis of hydrodynamics and heat transfer in a thin liquid film flowing over a rotating disk surface is presented for both constant temperature and constant heat flux boundary conditions. The model is found to capture the correct trends of the liquid film thickness variation over the disk surface and compare reasonably well with experimental results over the range of Reynolds and Rossby numbers covering both inertia and rotation dominated regimes. Nusselt number variation over the disk surface shows two types of behavior. At low rotation rates, the Nusselt number exhibits a radial decay with Nusselt number magnitudes increasing with higher inlet Reynolds number for both constant wall temperature and heat flux cases. At high rotation rates, the Nusselt number profiles exhibit a peak whose location advances radially outward with increasing film Reynolds number or inertia. The results also compare favorably with the full numerical simulation results from an earlier study as well as with the reported experimental results.

  2. Experimental investigation of trailing edge noise from stationary and rotating airfoils

    PubMed Central

    Zajamsek, Branko; Doolan, Con J.; Moreau, Danielle J.; Fischer, Jeoffrey; Prime, Zebb

    2017-01-01

    Trailing edge noise from stationary and rotating NACA 0012 airfoils is characterised and compared with a noise prediction based on the semi-empirical Brooks, Pope, and Marcolini (BPM) model. The NACA 0012 is symmetrical airfoil with no camber and 12% thickness to chord length ratio. Acoustic measurements were conducted in an anechoic wind tunnel using a stationary NACA 0012 airfoil at 0° pitch angle. Airfoil self-noise emissions from rotating NACA 0012 airfoils mounted at 0° and 10° pitch angles on a rotor-rig are studied in an anechoic room. The measurements were carried out using microphone arrays for noise localisation and magnitude estimation using beamforming post-processing. Results show good agreement between peak radiating trailing edge noise emissions of stationary and rotating NACA 0012 airfoils in terms of the Strouhal number. Furthermore, it is shown that noise predictions based on the BPM model considering only two dimensional flow effects, are in good agreement with measurements for rotating airfoils, at these particular conditions. PMID:28599535

  3. Experimental investigation of trailing edge noise from stationary and rotating airfoils.

    PubMed

    Zajamsek, Branko; Doolan, Con J; Moreau, Danielle J; Fischer, Jeoffrey; Prime, Zebb

    2017-05-01

    Trailing edge noise from stationary and rotating NACA 0012 airfoils is characterised and compared with a noise prediction based on the semi-empirical Brooks, Pope, and Marcolini (BPM) model. The NACA 0012 is symmetrical airfoil with no camber and 12% thickness to chord length ratio. Acoustic measurements were conducted in an anechoic wind tunnel using a stationary NACA 0012 airfoil at 0° pitch angle. Airfoil self-noise emissions from rotating NACA 0012 airfoils mounted at 0° and 10° pitch angles on a rotor-rig are studied in an anechoic room. The measurements were carried out using microphone arrays for noise localisation and magnitude estimation using beamforming post-processing. Results show good agreement between peak radiating trailing edge noise emissions of stationary and rotating NACA 0012 airfoils in terms of the Strouhal number. Furthermore, it is shown that noise predictions based on the BPM model considering only two dimensional flow effects, are in good agreement with measurements for rotating airfoils, at these particular conditions.

  4. Noninvasive measurement of burn wound depth applying infrared thermal imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Jaspers, Mariëlle E.; Maltha, Ilse M.; Klaessens, John H.; Vet, Henrica C.; Verdaasdonk, Rudolf M.; Zuijlen, Paul P.

    2016-02-01

    In burn wounds early discrimination between the different depths plays an important role in the treatment strategy. The remaining vasculature in the wound determines its healing potential. Non-invasive measurement tools that can identify the vascularization are therefore considered to be of high diagnostic importance. Thermography is a non-invasive technique that can accurately measure the temperature distribution over a large skin or tissue area, the temperature is a measure of the perfusion of that area. The aim of this study was to investigate the clinimetric properties (i.e. reliability and validity) of thermography for measuring burn wound depth. In a cross-sectional study with 50 burn wounds of 35 patients, the inter-observer reliability and the validity between thermography and Laser Doppler Imaging were studied. With ROC curve analyses the ΔT cut-off point for different burn wound depths were determined. The inter-observer reliability, expressed by an intra-class correlation coefficient of 0.99, was found to be excellent. In terms of validity, a ΔT cut-off point of 0.96°C (sensitivity 71%; specificity 79%) differentiates between a superficial partial-thickness and deep partial-thickness burn. A ΔT cut-off point of -0.80°C (sensitivity 70%; specificity 74%) could differentiate between a deep partial-thickness and a full-thickness burn wound. This study demonstrates that thermography is a reliable method in the assessment of burn wound depths. In addition, thermography was reasonably able to discriminate among different burn wound depths, indicating its potential use as a diagnostic tool in clinical burn practice.

  5. Optimal treatment of partial thickness burns in children: a systematic review.

    PubMed

    Vloemans, A F P M; Hermans, M H E; van der Wal, M B A; Liebregts, J; Middelkoop, E

    2014-03-01

    A large part of the patient population of a burn centre consists of children, most of whom are younger than four years. The majority of these young children suffer from superficial and deep partial thickness scald burns that may easily deepen to full thickness burns. A proper wound therapy, that prevents infection and ensures a moist wound condition, might prevent the deterioration of the wound. Therefore, we performed a systematic review of wound management and dressing materials to select the best treatment option for children with burns. A search in Medline and Embase revealed 51 articles for a critical appraisal. The articles were divided into randomized controlled trials, cohort studies and a group of case-reports. Total appraisal did not differ much amongst the groups; the level of evidence was highest in the randomized controlled trials and lowest in the case-reports. In 16 out of 34 comparative studies, silver sulfadiazine or a silver sulfadiazine/chlorhexidine-gluconate combination was the standard of wound care treatment. The competitor dressing was Biobrane(®) in six studies and amnion membrane in three. Tulle gauze, or tulle gauze impregnated with an antibacterial addition were the standard of care treatment in seven studies. In general, membranous dressings like Biobrane(®) and amnion membrane performed better than the standard of care on epithelialization rate, length of hospital stay and pain for treatment of partial thickness burns in children. However, hardly any of the studies investigated long-term results like scar formation. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  6. High Rotation Speed Friction Stir Welding for 2014 Aluminum Alloy Thin Sheets

    NASA Astrophysics Data System (ADS)

    Chen, Shujin; Zhou, Yang; Xue, Junrong; Ni, Ruiyang; Guo, Yue; Dong, Jianghui

    2017-03-01

    In this study, 2014 aluminum alloy sheets with 1 mm thickness are welded successfully by friction stir welding (FSW) robot under the condition of high rotation speed. When the high rotation speed of 10,000-16,500 rpm is applied, the lower axial pressure (less than 200 N) is obtained, which reduces stiffness requirements for equipment. Welding deformation is inevitable because high rotation speed can easily result in rapid heating rate and uneven heat input. The welding distortion caused by two cooling methods is measured, respectively, by laser range finder. The experimental results show that the welding distortion is smaller under the condition of water cooling. When the rotation speed is up to 15,000 rpm and welding speed 50-170 mm/min, the whole welding process is controllable. Under the higher rotation speed condition, the welding defects disappear gradually and more stable mechanical properties can be obtained up to 75% of base metal (ω = 16,000 rpm, ν = 110 mm/min). The results of different welding parameters demonstrate that the high rotation speed can increase material mixing and reduce the axial force (z force), and it can benefit lightweight sheet welding by using FSW robot.

  7. Design of electrostatically levitated micromachined rotational gyroscope based on UV-LIGA technology

    NASA Astrophysics Data System (ADS)

    Cui, Feng; Chen, Wenyuan; Su, Yufeng; Zhang, Weiping; Zhao, Xiaolin

    2004-12-01

    The prevailing micromachined vibratory gyroscope typically has a proof mass connected to the substrate by a mechanical suspension system, which makes it face a tough challenge to achieve tactical or inertial grade performance levels. With a levitated rotor as the proof mass, a micromachined rotational gyroscope will potentially have higher performance than vibratory gyroscope. Besides working as a moment rebalance dual-axis gyroscope, the micromachined rotational gyroscope based on a levitated rotor can simultaneously work as a force balance tri-axis accelerometer. Micromachined rotational gyroscope based on an electrostatically levitated silicon micromachined rotor has been notably developed. In this paper, factors in designing a rotational gyro/accelerometer based on an electrostatically levitated disc-like rotor, including gyroscopic action of micro rotor, methods of stable levitation, micro displacement detection and control, rotation drive and speed control, vacuum packaging and microfabrication, are comprehensively considered. Hence a design of rotational gyro/accelerometer with an electroforming nickel rotor employing low cost UV-LIGA technology is presented. In this design, a wheel-like flat rotor is proposed and its basic dimensions, diameter and thickness, are estimated according to the required loading capability. Finally, its micromachining methods based on UV-LIGA technology and assembly technology are discussed.

  8. Finite-size versus interface-proximity effects in thin-film epitaxial SrTiO3

    NASA Astrophysics Data System (ADS)

    De Souza, R. A.; Gunkel, F.; Hoffmann-Eifert, S.; Dittmann, R.

    2014-06-01

    The equilibrium electrical conductivity of epitaxial SrTiO3 (STO) thin films was investigated as a function of temperature, 950≤ T/K ≤1100, and oxygen partial pressure, 10-23≤ pO2/bar ≤1. Compared with single-crystal STO, nanoscale thin-film STO exhibited with decreasing film thickness an increasingly enhanced electronic conductivity under highly reducing conditions, with a corresponding decrease in the activation enthalpy of conduction. This implies substantial modification of STO's point-defect thermodynamics for nanoscale film thicknesses. We argue, however, against such a finite-size effect and for an interface-proximity effect. Indeed, assuming trapping of oxygen vacancies at the STO surface and concomitant depletion of oxygen vacancies—and accumulation of electrons—in an equilibrium surface space-charge layer, we are able to predict quantitatively the conductivity as a function of temperature, oxygen partial pressure, and film thickness. Particularly complex behavior is predicted for ultrathin films that are consumed entirely by space charge.

  9. Elucidation of Two Giants: Challenges to Thick-shell Synthesis in CdSe/ZnSe and ZnSe/CdS Core/Shell Quantum Dots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acharya, Krishna P.; Nguyen, Hue M.; Paulite, Melissa

    2015-03-06

    Core/thick-shell "giant" quantum dots (gQDs) possessing type II electronic structures exhibit suppressed blinking and diminished nonradiative Auger recombination. Here we investigate CdSe/ZnSe and ZnSe/CdS as potential new gQDs. We show theoretically and experimentally that both can exhibit partial or complete spatial separation of an excited-state electron–hole pair (i.e., type II behavior). However, we reveal that thick-shell growth is challenged by competing processes: alloying and cation exchange. We demonstrate that these can be largely avoided by choice of shelling conditions (e.g., time, temperature, and QD core identity). The resulting CdSe/ZnSe gQDs exhibit unusual single-QD properties, principally emitting from dim gray statesmore » but having high two-exciton (biexciton) emission efficiencies, whereas ZnSe/CdS gQDs show characteristic gQD blinking suppression, though only if shelling is accompanied by partial cation exchange.« less

  10. Deformation partitioning and fabric development during shearing of felsic migmatites (Valpelline Series, NW Alps)

    NASA Astrophysics Data System (ADS)

    Pariani, Federico; Menegon, Luca; Bistacchi, Andrea; Malaspina, Nadia

    2014-05-01

    The relationships between partial melting and deformation in the continental lower crust are critical for understanding lithosphere rheology and the processes leading to melt segregation. In metapelitic rocks in the lower portions of the crust partial melting typically occurs via dehydration of biotite and is generally characterized by a negative volume change when garnet is produced as a peritectic phase. As a result, segregation of biotite-derived melt by fracturing resulting from dilational strain is not common. Hence segregation of biotite-derived melts in the lower crust is likely to be controlled by active deformation via creation of structural anisotropies (fabric), which define migration pathways from the grain-size to the kilometre scale. This study investigates the relations between deformation mechanisms of minerals, fabric development and grain- and meso-scale deformation partitioning in felsic migmatites. The study area is located in the Valpelline Series of the Dent Blanche Nappe in the north-western Alps, which represents a slice of pre-Alpine lower crust dominated by metapelitic migmatites (i.e. 'kinzigites' in the Alpine literature). The migmatites are stromatic and show a leucosome-melanosome interlayering defining the dominant foliation (S2), which forms along a sinistral shear zone at least 1 km thick and laterally continuous for at least 8 km. Ti-in biotite geothermometry, mineral inclusions in garnet, and literature data indicate that S2 formed at P, T conditions of 800-820°C, 0.4-0.7 GPa, during dehydration melting of biotite. The melanosomes have about 80 vol% of garnet + biotite + sillimanite and are very poor in quartz and feldspars, indicating almost complete removal of melt. Garnet forms slightly elongated grains wrapped by biotite and sillimanite layers. Compositional maps of the elongated garnet do not show any zonation. EBSD analysis indicates that the elongated garnets are actually clusters of individual grains with no internal misorientation. We interpret these microstructures as deriving from amalgamation of individual garnets in elongated sites during shearing. Prismatic sillimanite has a strong crystallographic preferred orientation (CPO) with the c-axes parallel to the stretching lineation. However, evidence for internal misorientaton is scarce, indicating that the CPO was probably achieved by passive rotation during shearing. Elongated K-feldspar grains also do not show any internal misorientation and crystal plasticity features. They are rich of sillimanite and quartz inclusions, suggesting that they represent melt pockets crystallized near the site of production. K-feldspar has a weak CPO with the (010) planes parallel to the foliation and either <100> or <101> axis parallel to the lineation. The high aspect ratio was probably achieved by oriented growth during crystallization of melt. In summary, deformation mechanisms of minerals during melt removal from the melanosome seem to be dominated by passive rotation and oriented growth during magmatic flow, with negligible contribution of dislocation creep. A large (at least several hundred metres thick across foliation) low-strain domain of less pelitic, more quartzofeldspathic composition has escaped the pervasive development of S2. This domain preserves an S1 associated with older stages of partial melting. We speculate that the different bulk and mineralogical composition, reflecting the different nature of the protolith but also the effect of pre-existing melting episodes, determined a reduced melting during D2. This resulted in localization of deformation along melt-richer portions of this lower crustal section.

  11. Comparing oil based ointment versus standard practice for the treatment of moderate burns in Greece: a trial based cost effectiveness evaluation

    PubMed Central

    2011-01-01

    Background The local treatment of burn wounds has long been a subject of debate. The objective of this study was to compare the cost and the effectiveness of Moist Exposed Burn Ointment -MEBO versus a combination of povidone iodine plus bepanthenol cream for partial thickness burns. Methods The study was carried out in the Burn Center of a state hospital in Athens, Greece. 211 patients needing conservative therapy were prospectively selected according to the depth of the burn wound. The treatment was allocated according to the Stratified Randomization Design. The outcomes measured were mean cost of in-hospital stay, rate of complications, time of 50% wound healing, pain scores, in hospital stay diminution. We have adopted a societal perspective. Results In the total groups MEBO presented lower cost, (although not significantly different: p = 0.10) and better effectiveness. The data suggest that MEBO is the dominant therapy for superficial partial burn wound with significantly lower costs and significantly higher effectiveness due to a lesser time of recovery and consequently lower time of hospitalization and follow-up. MEBO presented similar percentages of complications with the comparator, lower pain levels and smaller time of no healthy appearance of the burn limits for superficial partial thickness burns. Conclusions The data suggested that topical application of MEBO may be considered for further investigation as a potential first-line treatment modality for superficial partial thickness burns. Trial registration The trial has been registered on the International Standard Randomised Controlled Trial Number Register (ISRCTN) and given the registration number ISRCTN74058791. PMID:22132709

  12. Comparing oil based ointment versus standard practice for the treatment of moderate burns in Greece: a trial based cost effectiveness evaluation.

    PubMed

    Carayanni, Vilelmine J; Tsati, Evangelia G; Spyropoulou, Georgia C H; Antonopoulou, Fotini N; Ioannovich, John D

    2011-12-01

    The local treatment of burn wounds has long been a subject of debate. The objective of this study was to compare the cost and the effectiveness of Moist Exposed Burn Ointment -MEBO versus a combination of povidone iodine plus bepanthenol cream for partial thickness burns. The study was carried out in the Burn Center of a state hospital in Athens, Greece. 211 patients needing conservative therapy were prospectively selected according to the depth of the burn wound. The treatment was allocated according to the Stratified Randomization Design. The outcomes measured were mean cost of in-hospital stay, rate of complications, time of 50% wound healing, pain scores, in hospital stay diminution. We have adopted a societal perspective. In the total groups MEBO presented lower cost, (although not significantly different: p = 0.10) and better effectiveness. The data suggest that MEBO is the dominant therapy for superficial partial burn wound with significantly lower costs and significantly higher effectiveness due to a lesser time of recovery and consequently lower time of hospitalization and follow-up. MEBO presented similar percentages of complications with the comparator, lower pain levels and smaller time of no healthy appearance of the burn limits for superficial partial thickness burns. The data suggested that topical application of MEBO may be considered for further investigation as a potential first-line treatment modality for superficial partial thickness burns. The trial has been registered on the International Standard Randomised Controlled Trial Number Register (ISRCTN) and given the registration number ISRCTN74058791.

  13. Electric field controlled strain induced reversible switching of magnetization in Galfenol nanomagnets delineated on PMN-PT substrate

    NASA Astrophysics Data System (ADS)

    Ahmad, Hasnain; Atulasimha, Jayasimha; Bandyopadhyay, Supriyo

    We report a non-volatile converse magneto-electric effect in elliptical Galfenol (FeGa) nanomagnets of ~300 nm lateral dimensions and ~10nm thickness delineated on a PMN-PT substrate. This effect can be harnessed for energy-efficient non-volatile memory. The nanomagnets are fabricated with e-beam lithography and sputtering. Their major axes are aligned parallel to the direction in which the substrate is poled and they are magnetized in this direction with a magnetic field. An electric field in the opposite direction generates compressive strain in the piezoelectric substrate which is partially transferred to the nanomagnets and rotates their magnetization away from the major axes to metastable orientations. There they remain after the field is removed, resulting in non-volatility. Reversing the electric field generates tensile strain which returns the magnetization to the original state. The two states can encode two binary bits which can be written using the correct voltage polarity, resulting in non-toggle behavior. Scaled memory fashioned on this effect can exhibit write energy dissipation of only ~2 aJ. Work is supported by NSF under ECCS-1124714 and CCF-1216614. Sputtering was carried out at NIST Gaithersburg.

  14. Unusual Contact-Line Dynamics of Thick Films and Drops

    NASA Technical Reports Server (NTRS)

    Veretennikov, Igor; Agarwal, Abhishek; Indeikina, Alexandra; Chang, Hsueh-Chia

    1999-01-01

    We report several novel phenomena In contact-line and fingering dynamics of macroscopic spinning drops and gravity-driven films with dimensions larger than the capillary length. It is shown through experimental and theoretical analysis that such macroscopic films can exhibit various interfacial shapes, including multi valued ones, near the contact line due to a balance between the external body forces with capillarity. This rich variety of front shapes couples with the usual capillary, viscous, and intermolecular forces at the contact line to produce a rich and unexpected spectrum of contact-line dynamics. A single finger develops when part of the front becomes multivalued on a partially wetting macroscopic spinning drop in contrast to a different mechanism for microscopic drops of completely wetting fluids. Contrary to general expectation, we observe that, at high viscosity and low frequencies of rotation, the speed of a glycerine finger increases with increasing viscosity. Completely wetting Dow Corning 200 Fluid spreads faster over a dry inclined plane than a prewetted one. The presence of a thin prewetted film suppresses fingering both for gravity-driven flow and for spin coating. We analyze some of these unique phenomena in detail and offer qualitative physical explanations for the others.

  15. Effects of the calcium channel blocker verapamil and sulphydryl reducing agent dithiothreitol on atractyloside toxicity in precision-cut rat renal cortical and liver slices.

    PubMed

    Obatomi, D K; Blackburn, R O; Bach, P H

    2001-10-01

    The effects of dithiothreitol (DTT), a sulfhydryl-containing agent and verapamil (VRP), a calcium channel blocker as possible cytoprotectants against the atractyloside-induced toxicity were characterized in rat kidney and liver slices in vitro using multiple markers of toxicity. Precision-cut slices (200 microM thick) were either incubated with atractyloside (2 mM) or initially preincubated with either DTT (5 mM) or VRP (100 microM) for 30 min followed by exposure to atractyloside (2 mM) for 3 h at 37 degrees C on a rocker platform rotated at approximately 3 rpm. All of the toxicity parameters were sensitive to exposure to atractyloside, but treatment with DTT or VRP alone did not provide any indication of damage to the tissues. Preincubation of slices containing either DTT or VRP for 30 min provided total protection against atractyloside-induced increase in LDH leakage in both kidney and liver slices. Increased induction of lipid peroxidation by atractyloside in liver slices was completely abolished by DTT and VRP. Both DTT and VRP provided partial protection against atractyloside-induced inhibition of gluconeogenesis in both kidney and liver slices. Atractyloside-induced ATP depletion in both kidney and liver slices was partially abolished by VRP but not DTT. The significant depletion of GSH in the kidney slices by atractyloside was completely reversed by DTT only, while VRP alone reversed the same process in liver slices. Decreased MTT reductive capacity and significant increase in ALT leakage caused by atractyloside in liver slices was partially reversed. Complete protection was achieved with both DTT and VRP against atractyloside-induced inhibition of PAH uptake in kidney slices. These findings suggest that both DTT and VRP exert cytoprotective effects in atractyloside-induced biochemical perturbation, effects that differ in liver and kidney. The effect of these agents on atractyloside has provided us with a further understanding of the molecular mechanism of its action.

  16. Thickness of a Europan ice shell from impact crater simulations.

    PubMed

    Turtle, E P; Pierazzo, E

    2001-11-09

    Several impact craters on Jupiter's satellite Europa exhibit central peaks. On the terrestrial planets, central peaks consist of fractured but competent rock uplifted during cratering. Therefore, the observation of central peaks on Europa indicates that an ice layer must be sufficiently thick that the impact events did not completely penetrate it. We conducted numerical simulations of vapor and melt production during cratering of water ice layers overlying liquid water to estimate the thickness of Europa's icy crust. Because impacts disrupt material well beyond the zone of partial melting, our simulations put a lower limit on ice thickness at the locations and times of impact. We conclude that the ice must be more than 3 to 4 kilometers thick.

  17. Chemical reactions and morphological stability at the Cu/Al2O3 interface.

    PubMed

    Scheu, C; Klein, S; Tomsia, A P; Rühle, M

    2002-10-01

    The microstructures of diffusion-bonded Cu/(0001)Al2O3 bicrystals annealed at 1000 degrees C at oxygen partial pressures of 0.02 or 32 Pa have been studied with various microscopy techniques ranging from optical microscopy to high-resolution transmission electron microscopy. The studies revealed that for both oxygen partial pressures a 20-35 nm thick interfacial CuAlO2 layer formed, which crystallises in the rhombohedral structure. However, the CuAlO2 layer is not continuous, but interrupted by many pores. In the samples annealed in the higher oxygen partial pressure an additional reaction phase with a needle-like structure was observed. The needles are several millimetres long, approximately 10 microm wide and approximately 1 microm thick. They consist of CuAlO2 with alternating rhombohedral and hexagonal structures. Solid-state contact angle measurements were performed to derive values for the work of adhesion. The results show that the adhesion is twice as good for the annealed specimen compared to the as-bonded sample.

  18. Methods and systems for monitoring a solid-liquid interface

    DOEpatents

    Stoddard, Nathan G [Gettysburg, PA; Clark, Roger F [Frederick, MD

    2011-10-04

    Methods and systems are provided for monitoring a solid-liquid interface, including providing a vessel configured to contain an at least partially melted material; detecting radiation reflected from a surface of a liquid portion of the at least partially melted material; providing sound energy to the surface; measuring a disturbance on the surface; calculating at least one frequency associated with the disturbance; and determining a thickness of the liquid portion based on the at least one frequency, wherein the thickness is calculated based on L=(2m-1)v.sub.s/4f, where f is the frequency where the disturbance has an amplitude maximum, v.sub.s is the speed of sound in the material, and m is a positive integer (1, 2, 3, . . . ).

  19. Collision effects on propagation characteristics of electromagnetic waves in a sub-wavelength plasma slab of partially ionized dense plasmas

    NASA Astrophysics Data System (ADS)

    Bowen, LI; Zhibin, WANG; Qiuyue, NIE; Xiaogang, WANG; Fanrong, KONG; Zhenyu, WANG

    2018-01-01

    Intensive collisions between electrons and neutral particles in partially ionized plasmas generated in atmospheric/sub-atmospheric pressure environments can sufficiently affect the propagation characteristics of electromagnetic waves, particularly in the sub-wavelength regime. To investigate the collisional effect in such plasmas, we introduce a simplified plasma slab model with a thickness on the order of the wavelength of the incident electromagnetic wave. The scattering matrix method (SMM) is applied to solve the wave equation in the plasma slab with significant nonuniformity. Results show that the collisions between the electrons and the neutral particles, as well as the incident angle and the plasma thickness, can disturb the transmission and reduce reflection significantly.

  20. New possibilities for tuning ultrathin cobalt film magnetic properties by a noble metal overlayer.

    PubMed

    Kisielewski, M; Maziewski, A; Tekielak, M; Wawro, A; Baczewski, L T

    2002-08-19

    Complementary multiscale magneto-optical studies based on the polar Kerr effect are carried out on an ultrathin cobalt wedge covered with a silver wedge and subsequently with the Au thick layer. A few monolayers of Ag are found to have a substantial effect on magnetic anisotropy, the coercivity field, and Kerr rotation. The silver overlayer thickness-driven magnetic reorientation from easy axis to easy plane generates a new type of 90 degrees magnetic wall for cobalt thicknesses between 1.3 and 1.8 nm. The tuning of the wall width in a wide range is possible. Tailoring of the overlayer structure can be used for ultrathin film magnetic patterning.

  1. Surgical Versus Nonsurgical Management of Rotator Cuff Tears: Predictors of Treatment Allocation.

    PubMed

    Kweon, Christopher; Gagnier, Joel J; Robbins, Christopher B; Bedi, Asheesh; Carpenter, James E; Miller, Bruce S

    2015-10-01

    Rotator cuff tears are a common shoulder disorder resulting in significant disability to patients and financial burden on the health care system. While both surgical and nonsurgical management are accepted treatment options, there is a paucity of data to support a treatment algorithm for care providers. Defining variables to guide treatment allocation may be important for patient education and counseling, as well as to deliver the most efficient care plan at the time of presentation. To identify independent variables at the time of initial clinical presentation that are associated with preferred allocation to surgical versus nonsurgical management for patients with known full-thickness rotator cuff tears. Case control study; Level of evidence, 3. A total of 196 consecutive adult patients with known full-thickness rotator cuff tears were enrolled into a prospective cohort study. Robust data were collected for each subject at baseline, including age, sex, body mass index (BMI), shoulder activity score, smoking status, size of cuff tear, duration of symptoms, functional comorbidity index, the American Shoulder and Elbow Surgeons (ASES) score, the Western Ontario Rotator Cuff index (WORC), and the Veterans Rand 12-Item Health Survey (VR-12). Logistic regression was performed to identify variables associated with treatment allocation, and the corresponding odds ratios were calculated. Of the 196 patients enrolled, 112 underwent surgical intervention and 84 nonoperative management. With covariates controlled for, significant baseline patient characteristics predictive of eventual allocation to surgical treatment included younger age, lower BMI, and durations of symptoms less than 1 year. Increasing age, higher BMI, and duration of symptoms longer than 1 year were predictive of nonsurgical treatment. Factors that were not associated with treatment allocation included sex, tear size, functional comorbidity score, or any of the patient-derived outcome scores at presentation (ASES, WORC, VR-12, shoulder activity score). Patient demographics at the time of initial presentation for a symptomatic rotator cuff tear are more predictive of treatment allocation to a surgical or nonoperative approach than the patient-derived outcome scores for activity level and shoulder disability. Further study is warranted to help define appropriate indications for treatment allocation in patients with rotator cuff tears. © 2015 The Author(s).

  2. Free Vibration Characteristics of Functionally Graded Pre-twisted Conical Shells under Rotation

    NASA Astrophysics Data System (ADS)

    Das, Apurba; Karmakar, Amit

    2017-06-01

    This article deals with effect of rotation and pretwist angle on free vibration characteristics of functionally graded conical shells. The dynamic equilibrium equation is derived from Lagrange's equation neglecting the Coriolis effect for moderate rotational speeds. The materials properties of conical shell are varied with a power-law distribution of the volume fractions of their constituents through its thickness. Convergence studies are performed in respect of mesh sizes, and comparisons of the present solutions and those reported in open literature are provided to substantiate the accuracy of the proposed method. Computer codes developed to obtain the numerical results for the combined effects of twist angle and rotational speed on the natural frequencies of functionally graded conical shells. The mode shapes for a typical laminate configuration under different conditions are also illustrated. Numerical results are obtained for the non-dimensional fundamental (NDFF) and second frequencies (NDSF).

  3. An on-line monitoring system for oil-film, pressure and temperature distributions in large-scale hydro-generator bearings

    NASA Astrophysics Data System (ADS)

    Höbel, M.; Haffner, K.

    1999-05-01

    Instrumentation that allows the behaviour of a hydro-generator thrust bearing to be monitored during operation is described. The measurement system was developed at the Asea Brown Boveri corporate research centre in Switzerland and was tested under realistic operating conditions at the Harbin Electric Machinery Company bearing-testing facility in the People's Republic of China. Newly developed fibre-optical proximity probes were used for the on-line monitoring of the thin oil film between the static and rotating parts of the bearing. These sensors are based on a back-reflection technique and can be used for various target materials such as Babbitt and Teflon. The monitoring system comprises about 120 temperature sensors, four pressure sensors and five optical oil-film thickness sensors. Temperature sensors are installed at specific static locations, whereas pressure and oil-film sensors are positioned in the runner and generate data during rotation. A special feature of the monitoring equipment is its on-line processing capability. Digital signal processors operating in parallel handle pressure and oil-film thickness data. Important measurement parameters such as the maximum pressure, maximum temperature and minimum oil-film thickness are displayed on-line. Detailed three-dimensional temperature information on one of the load segments can be obtained from subsequent off-line data analysis. The system also calculates two-dimensional plots of the oil-film thickness and pressure for most of the 12 load segments.

  4. Gate-tunable resonant tunneling in double bilayer graphene heterostructures.

    PubMed

    Fallahazad, Babak; Lee, Kayoung; Kang, Sangwoo; Xue, Jiamin; Larentis, Stefano; Corbet, Christopher; Kim, Kyounghwan; Movva, Hema C P; Taniguchi, Takashi; Watanabe, Kenji; Register, Leonard F; Banerjee, Sanjay K; Tutuc, Emanuel

    2015-01-14

    We demonstrate gate-tunable resonant tunneling and negative differential resistance in the interlayer current-voltage characteristics of rotationally aligned double bilayer graphene heterostructures separated by hexagonal boron nitride (hBN) dielectric. An analysis of the heterostructure band alignment using individual layer densities, along with experimentally determined layer chemical potentials indicates that the resonance occurs when the energy bands of the two bilayer graphene are aligned. We discuss the tunneling resistance dependence on the interlayer hBN thickness, as well as the resonance width dependence on mobility and rotational alignment.

  5. Implementation of Free-Formulation-Based Flat Shell Elements into NASA Comet Code and Development of Nonlinear Shallow Shell Element

    NASA Technical Reports Server (NTRS)

    Barut, A.; Madenci, Erdogan; Tessler, A.

    1997-01-01

    This study presents a transient nonlinear finite element analysis within the realm of a multi-body dynamics formulation for determining the dynamic response of a moderately thick laminated shell undergoing a rapid and large rotational motion and nonlinear elastic deformations. Nonlinear strain measure and rotation, as well as 'the transverse shear deformation, are explicitly included in the formulation in order to capture the proper motion-induced stiffness of the laminate. The equations of motion are derived from the virtual work principle. The analysis utilizes a shear deformable shallow shell element along with the co-rotational form of the updated Lagrangian formulation. The shallow shell element formulation is based on the Reissner-Mindlin and Marguerre theory.

  6. Separability and Entanglement in the Hilbert Space Reference Frames Related Through the Generic Unitary Transform for Four Level System

    NASA Astrophysics Data System (ADS)

    Man'ko, V. I.; Markovich, L. A.

    2018-02-01

    Quantum correlations in the state of four-level atom are investigated by using generic unitary transforms of the classical (diagonal) density matrix. Partial cases of pure state, X-state, Werner state are studied in details. The geometrical meaning of unitary Hilbert reference-frame rotations generating entanglement in the initially separable state is discussed. Characteristics of the entanglement in terms of concurrence, entropy and negativity are obtained as functions of the unitary matrix rotating the reference frame.

  7. Quantum noise in bright soliton matterwave interferometry

    NASA Astrophysics Data System (ADS)

    Haine, Simon A.

    2018-03-01

    There has been considerable recent interest in matterwave interferometry with bright solitons in quantum gases with attractive interactions, for applications such as rotation sensing. We model the quantum dynamics of these systems and find that the attractive interactions required for the presence of bright solitons causes quantum phase-diffusion, which severely impairs the sensitivity. We propose a scheme that partially restores the sensitivity, but find that in the case of rotation sensing, it is still better to work in a regime with minimal interactions if possible.

  8. Photometric geodesy of main-belt asteroids. I - Lightcurves of 26 large, rapid rotators

    NASA Technical Reports Server (NTRS)

    Weidenschilling, S. J.; Chapman, C. R.; Davis, D. R.; Greenberg, R.; Levy, D. H.

    1987-01-01

    A 'photometric geodesy' program is selected on the basis of light-curve data from five years' observations of large, rapidly rotating asteroids, where the observing protocol was designed to obtain precise, absolute photometry at a wide variety of orbital longitudes and phase angles. A total of 257 complete or partial light-curves are obtained for 26 asteroids; the data set will allow the future determination of pole positions and shapes, as well as to constrain the geophysical traits of these bodies.

  9. Motor/generator

    DOEpatents

    Hickam, Christopher Dale [Glasford, IL

    2008-05-13

    A motor/generator is provided for connecting between a transmission input shaft and an output shaft of a prime mover. The motor/generator may include a motor/generator housing, a stator mounted to the motor/generator housing, a rotor mounted at least partially within the motor/generator housing and rotatable about a rotor rotation axis, and a transmission-shaft coupler drivingly coupled to the rotor. The transmission-shaft coupler may include a clamp, which may include a base attached to the rotor and a plurality of adjustable jaws.

  10. Evaluation of Outcome of Models at Fort Bliss, Texas

    DTIC Science & Technology

    1992-12-01

    15 Sex: M Age: 36 DOB: 5-13-55 Date of Injury: 8-2-91 Formal report received: 6-9-91 Injury: Shoulder strain, rotator cuff tear, and biceps tendon...right rotator cuff . COP: 2 days RTW: Returned to transitional work for two weeks, then to full duty. Job: mason Troop Clinic/WBAMC: All treatment was...flexor tendons of the right wrist; bilateral carpal tunnel syndrome; bilateral tendinitis . COP: 13 days RTW: Return to partial duty after COP. Reassigned

  11. Influence of basis images and skull position on evaluation of cortical bone thickness in cone beam computed tomography.

    PubMed

    Nascimento, Monikelly do Carmo Chagas; Boscolo, Solange Maria de Almeida; Haiter-Neto, Francisco; Santos, Emanuela Carla Dos; Lambrichts, Ivo; Pauwels, Ruben; Jacobs, Reinhilde

    2017-06-01

    The aim of this study was to assess the influence of the number of basis images and the orientation of the skull on the evaluation of cortical alveolar bone in cone beam computed tomography (CBCT). Eleven skulls with a total of 59 anterior teeth were selected. CBCT images were acquired by using 4 protocols, by varying the rotation of the tube-detector arm and the orientation of the skull (protocol 1: 360°/0°; protocol 2: 180°/0°; protocol 3: 180°/90°; protocol 4: 180°/180°). Observers evaluated cortical bone as absent, thin, or thick. Direct observation of the skulls was used as the gold standard. Intra- and interobserver agreement, as well as agreement of scoring between the 3 bone thickness classifications, were calculated by using the κ statistic. The Wilcoxon signed-rank test was used to compare the 4 protocols. For lingual cortical bone, protocol 1 showed no statistical difference from the gold standard. Higher reliability was found in protocol 3 for absent (κ = 0.80) and thin (κ = 0.47) cortices, whereas for thick cortical bone, protocol 2 was more consistent (κ = 0.60). In buccal cortical bone, protocol 1 obtained the highest agreement for absent cortices (κ = 0.61), whereas protocol 4 was better for thin cortical plates (κ = 0.38) and protocol 2 for thick cortical plates (κ = 0.40). No consistent effect of the number of basis images or head orientation for visual detection of alveolar bone was detected, except for lingual cortical bone, for which full rotation scanning showed improved visualization. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Non-linear dynamics of compound sawteeth in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, J.-H., E-mail: jae-heon.ahn@polytechnique.edu; Garbet, X.; Sabot, R.

    2016-05-15

    Compound sawteeth is studied with the XTOR-2F code. Non-linear full 3D magnetohydrodynamic simulations show that the plasma hot core is radially displaced and rotates during the partial crash, but is not fully expelled out of the q = 1 surface. Partial crashes occur when the radius of the q = 1 surface exceeds a critical value, at fixed poloidal beta. This critical value depends on the plasma elongation. The partial crash time is larger than the collapse time of an ordinary sawtooth, likely due to a weaker diamagnetic stabilization. This suggests that partial crashes result from a competition between destabilizing effects such as themore » q = 1 radius and diamagnetic stabilization.« less

  13. Three-dimensional solutions of the magnetohydrostatic equations for rigidly rotating magnetospheres in cylindrical coordinates

    NASA Astrophysics Data System (ADS)

    Wilson, F.; Neukirch, T.

    2018-01-01

    We present new analytical three-dimensional solutions of the magnetohydrostatic equations, which are applicable to the co-rotating frame of reference outside a rigidly rotating cylindrical body, and have potential applications to planetary magnetospheres and stellar coronae. We consider the case with centrifugal force only, and use a transformation method in which the governing equation for the "pseudo-potential" (from which the magnetic field can be calculated) becomes the Laplace partial differential equation. The new solutions extend the set of previously found solutions to those of a "fractional multipole" nature, and offer wider possibilities for modelling than before. We consider some special cases, and present example solutions.

  14. Interface stability in a slowly rotating, low gravity tank Experiments

    NASA Technical Reports Server (NTRS)

    Leslie, F.; Gans, R. F.

    1986-01-01

    Analytical models of liquid in partially-filled rotating tanks predict both the shape of the interface between the liquid and its vapor, and the stability of that interface. The models are of necessity incomplete and experimental data are needed to assess the approximations made. Presented are preliminary experimental studies both in the laboratory and in the low-gravity environment of a free-falling aircraft. Emphasis is placed on bubbles which intersect the container boundaries. Measurements of rotating equilibrium bubble shapes are in agreement with theoretical profiles derived from Laplace's formula. The interface shape depends on the contact angle, the radius of intersection with container, and the ratio of centrifugal force to surface tension.

  15. Rotating flow over a stretching sheet in nanofluid using Buongiorno model and thermophysical properties of nanoliquids

    NASA Astrophysics Data System (ADS)

    Bakar, Nor Ashikin Abu; Bachok, Norfifah; Arifin, Norihan Md.

    2017-08-01

    The boundary layer flow and heat transfer in rotating nanofluid over a stretching sheet using Buongiorno model and thermophysical properties of nanoliquids is studied. Four types of nanoparticles, namely silver (Ag), copper (Cu), alumina (Al2O3) and titania (TiO2) are used in our analysis with water as the base fluid (Prandtl number, Pr = 6.2). The nonlinear partial differential equations are transformed into ordinary differential equations by using the similarity transformation. The numerical solutions of these equation is obtained using shooting method in Maple software. The numerical results is concentrated on the effects of nanoparticle volume fraction φ, Brownian motion Nb, thermophoresis Nt, rotation Ω and suction S parameters on the skin friction coefficient and heat transfer rate. Dual solutions are observed in a certain range of the rotating parameter.

  16. Shape effects in the turbulent tumbling of large particles

    NASA Astrophysics Data System (ADS)

    Variano, Evan; Oehmke, Theresa; Pujara, Nimish

    2017-11-01

    We present laboratory results on rotation of finite-sized, neutrally buoyant, anisotropic particles in isotropic turbulence. The isotropic turbulent flow is generated using a randomly-actuated synthetic jet array that minimizes tank scale circulation and measurements are made with stereoscopic particle image velocimetry. By using particles of different shapes, we explore the effects that symmetries have on particle rotation. We add to previous data collected for spheres cylinders and ellipsoids by performing new measurements on cubes, cuboids and cones. The measurement technique and results on mean-square particle rotation will be presented. Preliminary results, at the time of writing this abstract, indicate that symmetry breaking increases the rate of particle rotation. More complete quantitative results will be presented. This work was partially supported by the NSF award ENG-1604026 and by the Army Research Office Biomathematics Program.

  17. Channel plate for DNA sequencing

    DOEpatents

    Douthart, R.J.; Crowell, S.L.

    1998-01-13

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface. 15 figs.

  18. 76 FR 35425 - Notice of Intent to Grant Partially Exclusive License of the United States Patent Application No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-17

    ... like. For observation of the sample, embodiments provide a thin-membrane window etched in the center of... windows. This gap may be adjusted by employing spacers. Alternatively, the thickness of a film established... optimize resolution each window may have a thickness on the order of 50 nm and the gap may be on the order...

  19. Non-contacting Measurement of Oil Film Thickness Between Loaded Metallic Gear Teeth

    NASA Astrophysics Data System (ADS)

    Cox, Daniel B.; Ceccio, Steven L.; Dowling, David R.

    2013-11-01

    The mechanical power transmission efficiency of gears is depends on the lubrication condition between gear teeth. While the lubrication levels can be generally predicted, an effective in-situ non-contacting measurement of oil film thicknesses between loaded metallic gear teeth has proved elusive. This study explores a novel oil film thickness measurement technique based on optical fluence, the light energy transmitted between loaded gear teeth. A gear testing apparatus that allowed independent control of gear rotation rate, load torque, and oil flow was designed and built. Film thickness measurements made with 5-inch-pitch-diameter 60-tooth spur gears ranged from 0.3 to 10.2 mil. These results are compared with film thickness measurements made in an earlier investigation (MacConochie and Cameron, 1960), as well as with predictions from two film thickness models: a simple two-dimensional squeezed oil film and the industry-accepted model as described by the American Gear Manufacturers Association (AGMA 925, 2003). In each case, the measured film thicknesses were larger than the predicted thicknesses, though these discrepancies might be attributed to the specifics the experiments and to challenges associated with calibrating the fluence measurements. [Sponsored by General Electric].

  20. A rotation-translation invariant molecular descriptor of partial charges and its use in ligand-based virtual screening

    PubMed Central

    2014-01-01

    Background Measures of similarity for chemical molecules have been developed since the dawn of chemoinformatics. Molecular similarity has been measured by a variety of methods including molecular descriptor based similarity, common molecular fragments, graph matching and 3D methods such as shape matching. Similarity measures are widespread in practice and have proven to be useful in drug discovery. Because of our interest in electrostatics and high throughput ligand-based virtual screening, we sought to exploit the information contained in atomic coordinates and partial charges of a molecule. Results A new molecular descriptor based on partial charges is proposed. It uses the autocorrelation function and linear binning to encode all atoms of a molecule into two rotation-translation invariant vectors. Combined with a scoring function, the descriptor allows to rank-order a database of compounds versus a query molecule. The proposed implementation is called ACPC (AutoCorrelation of Partial Charges) and released in open source. Extensive retrospective ligand-based virtual screening experiments were performed and other methods were compared with in order to validate the method and associated protocol. Conclusions While it is a simple method, it performed remarkably well in experiments. At an average speed of 1649 molecules per second, it reached an average median area under the curve of 0.81 on 40 different targets; hence validating the proposed protocol and implementation. PMID:24887178

Top