Sample records for particulate control performance

  1. PARTICULATE EMISSIONS AND CONTROL IN FLUIDIZED-BED COMBUSTION: MODELING AND PARAMETRIC PERFORMANCE

    EPA Science Inventory

    The report discusses a model, developed to describe the physical characteristics of the particulates emitted from fluidized-bed combustion (FBC) systems and to evaluate data on FBC particulate control systems. The model, which describes the particulate emissions profile from FBC,...

  2. THE IMPACT OF PARTICULATE EMISSIONS CONTROL ON THE CONTROL OF OTHER MWC AIR EMISSIONS

    EPA Science Inventory

    On December 20, 1989, the Environmental Protection Agency (EPA) proposed revised new source performance standards for new municipal waste combustion (MWC) units and guidelines for existing sources. The proposed national regulations require tighter particulate matter control and a...

  3. PARTICULATE CONTROL HIGHLIGHTS: RESEARCH ON ELECTROSTATIC PRECIPITATOR TECHNOLOGY

    EPA Science Inventory

    The report gives highlights of a major EPA research program on electrostatic precipitator (ESP) technology, directed toward improving the performance of ESPs in controlling industrial particulate emissions, notably fly ash from coal combustion in electric power plants. Relationsh...

  4. 40 CFR 60.272a - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...

  5. 40 CFR 60.272a - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...

  6. 40 CFR 60.272 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.272... Standard for particulate matter. (a) On and after the date on which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf). (2) Exit from a...

  7. 40 CFR 60.272a - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...

  8. 40 CFR 60.272 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.272... Standard for particulate matter. (a) On and after the date on which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf). (2) Exit from a...

  9. 40 CFR 60.272a - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...

  10. 40 CFR 60.272 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.272... Standard for particulate matter. (a) On and after the date on which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf). (2) Exit from a...

  11. 40 CFR 60.272a - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...

  12. 40 CFR 60.272 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.272... Standard for particulate matter. (a) On and after the date on which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf). (2) Exit from a...

  13. Cost-effective particulate control options at Potomac Electric Power Company's Dickerson Station: An integrated approach to current and future particulate limits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christoffersen, S.W.; Rouse, G.T.; Krasnopoler, M.J.

    1998-07-01

    The Dickerson Generating Station evaluated several particulate control options to identify the most cost-effective option. The study's goals were to: eliminate the particulate scrubber and its high maintenance costs, and incorporate flexibility for low-sulfur coal and possible stricter emission limits. Each of the three Dickerson 190 MW units has a small 37-year-old electrostatic precipitator and a wet particulate scrubber. The study evaluated alternatives to replace the scrubber and enhance ESP performance: Existing ESP alternatives--Extend height of existing ESP; Flue gas conditioning. Scrubber stream alternatives--Partial-flow ESP or pulse jet baghouse. Full-flow alternatives--Supplemental ESP; COHPAC baghouse; replacement ESP or baghouse. A technicalmore » and economic prescreening eliminated some of the options. Capital, operating, and life cycle costs were estimated for the remaining options to determine the most cost-effective alternative. This paper will present the technical and economic evaluations done for this study, including performance and costs.« less

  14. EVALUATION OF FOUR NOVEL FINE PARTICULATE COLLECTION DEVICES

    EPA Science Inventory

    The report gives results of an experimental performance evaluation of four novel fine particulate control devices: the Johns-Manville Cleanable High-Efficiency Air Filtration (CHEAF) System, the APS Electrostatic Scrubber, the APS Electrotube, and the TRW Charged Droplet Scrubber...

  15. 40 CFR 60.381 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...

  16. 40 CFR 60.381 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...

  17. 40 CFR 60.381 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...

  18. 40 CFR 60.381 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...

  19. 40 CFR 60.381 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...

  20. Settling Efficiency of Urban Particulate Matter Transported by Stormwater Runoff.

    PubMed

    Carbone, Marco; Penna, Nadia; Piro, Patrizia

    2015-09-01

    The main purpose of control measures in urban areas is to retain particulate matter washed out by stormwater over impermeable surfaces. In stormwater control measures, particulate matter removal typically occurs via sedimentation. Settling column tests were performed to examine the settling efficiency of such units using monodisperse and heterodisperse particulate matter (for which the particle size distributions were measured and modelled by the cumulative gamma distribution). To investigate the dependence of settling efficiency from the particulate matter, a variant of the evolutionary polynomial regression (EPR), a Microsoft Excel function based on multi-objective EPR technique (EPR-MOGA), called EPR MOGA XL, was used as a data-mining strategy. The results from this study have shown that settling efficiency is a function of the initial total suspended solids (TSS) concentration and of the median diameter (d50 index), obtained from the particle size distributions (PSDs) of the samples.

  1. Performance characteristics of a low-volume PM10 sampler

    USDA-ARS?s Scientific Manuscript database

    Four identical PM10 pre-separators, along with four identical low-volume (1m3 hr-1) total suspended particulate (TSP) samplers were tested side-by-side in a controlled laboratory particulate matter (PM) chamber. The four PM10 and four TSP samplers were also tested in an oil pipe-cleaning field to ev...

  2. Electrically heated particulate filter propagation support methods and systems

    DOEpatents

    Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

    2011-06-07

    A control system that controls regeneration of a particulate filter is provided. The system generally includes a regeneration module that controls current to the particulate filter to initiate combustion of particulate matter in the particulate filter. A propagation module estimates a propagation status of the combustion of the particulate matter based on a combustion temperature. A temperature adjustment module controls the combustion temperature by selectively increasing a temperature of exhaust that passes through the particulate filter.

  3. Review of the state-of-the-art of exhaust particulate filter technology in internal combustion engines.

    PubMed

    Guan, Bin; Zhan, Reggie; Lin, He; Huang, Zhen

    2015-05-01

    The increasingly stringent emission regulations, such as US 2010, Tier 2 Bin 5 and beyond, off-road Tier 4 final, and Euro V/5 for particulate matter (PM) reduction applications, will mandate the use of the diesel particulate filters (DPFs) technology, which is proven to be the only way that can effectively control the particulate emissions. This paper covers a comprehensive overview of the state-of-the-art DPF technologies, including the advanced filter substrate materials, the novel catalyst formulations, the highly sophisticated regeneration control strategies, the DPF uncontrolled regenerations and their control methodologies, the DPF soot loading prediction, and the soot sensor for the PM on-board diagnostics (OBD) legislations. Furthermore, the progress of the highly optimized hybrid approaches, which involves the integration of diesel oxidation catalyst (DOC) + (DPF, NOx reduction catalyst), the selective catalytic reduction (SCR) catalyst coated on DPF, as well as DPF in the high-pressure exhaust gas recirculation (EGR) loop systems, is well discussed. Besides, the impacts of the quality of fuel and lubricant on the DPF performance and the maintenance and retrofit of DPF are fully elaborated. Meanwhile, the high efficiency gasoline particulate filter (GPF) technology is being required to effectively reduce the PM and particulate number (PN) emissions from the gasoline direct injection (GDI) engines to comply with the future increasingly stricter emissions regulations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. 40 CFR 52.2059 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) Pennsylvania has committed to undertake a comprehensive program... Investigating and Controlling Nontraditional Particulate Matter Emissions Task Completion date Scheduled tasks...

  5. 40 CFR 52.2059 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) Pennsylvania has committed to undertake a comprehensive program... Investigating and Controlling Nontraditional Particulate Matter Emissions Task Completion date Scheduled tasks...

  6. 40 CFR 52.2059 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) Pennsylvania has committed to undertake a comprehensive program... Investigating and Controlling Nontraditional Particulate Matter Emissions Task Completion date Scheduled tasks...

  7. 40 CFR 52.2059 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) Pennsylvania has committed to undertake a comprehensive program... Investigating and Controlling Nontraditional Particulate Matter Emissions Task Completion date Scheduled tasks...

  8. 40 CFR 1042.125 - Maintenance instructions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Emission... converters, electronic control units, particulate traps, trap oxidizers, components related to particulate..., electronic control units, particulate traps, trap oxidizers, components related to particulate traps and trap...

  9. 40 CFR 1042.125 - Maintenance instructions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Emission... converters, electronic control units, particulate traps, trap oxidizers, components related to particulate..., electronic control units, particulate traps, trap oxidizers, components related to particulate traps and trap...

  10. 40 CFR 1042.125 - Maintenance instructions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Emission... converters, electronic control units, particulate traps, trap oxidizers, components related to particulate..., electronic control units, particulate traps, trap oxidizers, components related to particulate traps and trap...

  11. 40 CFR 1042.125 - Maintenance instructions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Emission... converters, electronic control units, particulate traps, trap oxidizers, components related to particulate..., electronic control units, particulate traps, trap oxidizers, components related to particulate traps and trap...

  12. Electrically heated particulate filter restart strategy

    DOEpatents

    Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

    2011-07-12

    A control system that controls regeneration of a particulate filter is provided. The system generally includes a propagation module that estimates a propagation status of combustion of particulate matter in the particulate filter. A regeneration module controls current to the particulate filter to re-initiate regeneration based on the propagation status.

  13. Healing of rabbit calvarial critical-sized defects using autogenous bone grafts and fibrin glue.

    PubMed

    Lappalainen, Olli-Pekka; Korpi, Riikka; Haapea, Marianne; Korpi, Jarkko; Ylikontiola, Leena P; Kallio-Pulkkinen, Soili; Serlo, Willy S; Lehenkari, Petri; Sándor, George K

    2015-04-01

    This study aimed to evaluate ossification of cranial bone defects comparing the healing of a single piece of autogenous calvarial bone representing a bone flap as in cranioplasty compared to particulated bone slurry with and without fibrin glue to represent bone collected during cranioplasty. These defect-filling materials were then compared to empty control cranial defects. Ten White New Zealand adult male rabbits had bilateral critical-sized calvarial defects which were left either unfilled as control defects or filled with a single full-thickness piece of autogenous bone, particulated bone, or particulated bone combined with fibrin glue. The defects were left to heal for 6 weeks postoperatively before termination. CT scans of the calvarial specimens were performed. Histomorphometric assessment of hematoxylin-eosin- and Masson trichrome-stained specimens was used to analyze the proportion of new bone and fibrous tissue in the calvarial defects. There was a statistically significant difference in both bone and soft tissue present in all the autogenous bone-grafted defect sites compared to the empty negative control defects. These findings were supported by CT scan findings. While fibrin glue combined with the particulated bone seemed to delay ossification, the healing was more complete compared to empty control non-grafted defects. Autogenous bone grafts in various forms such as solid bone flaps or particulated bone treated with fibrin glue were associated with bone healing which was superior to the empty control defects.

  14. Electrically heated particulate filter preparation methods and systems

    DOEpatents

    Gonze, Eugene V [Pinckney, MI

    2012-01-31

    A control system that controls regeneration of a particulate filter is provided. The system generally includes a fuel control module that controls injection of fuel into exhaust that passes through the particulate filter. A regeneration module controls current to the particulate filter to initiate regeneration after the fuel has been injected into the exhaust.

  15. Electrically heated particulate filter regeneration methods and systems for hybrid vehicles

    DOEpatents

    Gonze, Eugene V.; Paratore, Jr., Michael J.

    2010-10-12

    A control system for controlling regeneration of a particulate filter for a hybrid vehicle is provided. The system generally includes a regeneration module that controls current to the particulate filter to initiate regeneration. An engine control module controls operation of an engine of the hybrid vehicle based on the control of the current to the particulate filter.

  16. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...

  17. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...

  18. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...

  19. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...

  20. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...

  1. 40 CFR 60.1325 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flue gases at the inlet of my particulate matter control device? 60.1325 Section 60.1325 Protection of... the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate... particulate matter control device. ...

  2. 40 CFR 60.1325 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... flue gases at the inlet of my particulate matter control device? 60.1325 Section 60.1325 Protection of... the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate... particulate matter control device. ...

  3. Performance of a Retrofitted Multicyclone for PM2.5 Emission Control

    NASA Astrophysics Data System (ADS)

    Dewika, M.; Rashid, M.; Ammar, M. R.

    2018-03-01

    This paper presents on the performance of a retrofitted multicyclone system, which aims to increase the collection efficiency of PM2.5 (i.e. particulate size fraction ≤ 2.5 μm) emission. The multicyclone was retrofitted by extracting 15% and 20% of the total volumetric air flow rate at the dust hopper of the unit using an additional Induced Draft Fan. The total collection efficiency with and without the extraction was measured at various air volumetric flow rates and particulate mass inlet concentration. The results showed that there was a reduction of 12% to 54% depending on the inlet concentration of PM2.5 emission in the stack with compared to without extraction increasing the collection efficiency of the retrofitted multicyclone. The finding suggests that a simple technique of applying gas extraction at the dust hopper of a multicyclone as reported in this study able to increase the overall performance in fine particulate collection.

  4. ETV TEST REPORT OF MOBILE SOURCE EMISSIONS CONTROL DEVICES: LUBRIZOL ENGINE CONTROL SYSTEMS PURIFILTER SC17L

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the Lubrizol Engine Control Systems Purifilter SC17L manufactured by Lubrizol Engine Control Systems. The technology is a precious and base metal, passively regenerated particulate filter...

  5. Gastric emptying of multi-particulate dosage forms.

    PubMed

    Newton, J Michael

    2010-08-16

    The evidence in the literature for the concept that multi-particulate dosage forms below a specific size empty from the stomach as if they were liquids and hence have the potential to provide the best solution to the formulation of controlled release oral dosage forms, has been considered. There is some evidence that particles less than 1.0mm provide a more rapid response than larger size particles but there is also evidence that this is not always the case and that rapid and reproducible gastric emptying of small particles does not always occur when they are administered. There is strong evidence that food can delay the gastric emptying of multi-particulate systems. Some of the misconception for gastric emptying performance of multi-particulate system is shown to be related to the limitation of the study design and limitation of the way the data is processed. Nevertheless, there is clear evidence that multi-particulate systems can provide effective oral controlled release dosage forms. There is still some way to go with experimental techniques which would allow a definitive answer to the issue of how the variability of the gastric emptying of multi-particulate systems of less than 2.0mm arises. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  6. PROCEEDINGS: EIGHTH SYMPOSIUM ON THE TRANSFER AND UTILIZATION OF PARTICULATE CONTROL TECHNOLOGY - VOLUME 2. BAGHOUSES AND PARTICULATE CONTROL FOR NEW APPLICATIONS

    EPA Science Inventory

    The two-volume proceedings describe the latest research and development efforts to improve particulate control devices, while treating traditional concerns of operational cost and compliance. Overall, particulate control remains a key issue in the cost and applicability of furnac...

  7. 40 CFR 52.1678 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: Particulate matter. 52.1678 Section 52.1678 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1678 Control strategy and regulations: Particulate matter. (a)-(c) [Reserved] (d) Section 227.3(a... CFR Subpart G, Control strategy: Sulfur oxides and particulate matter. (e) Determination of Attainment...

  8. 40 CFR 52.2059 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) [Reserved] (b) EPA approves the PM-10 attainment demonstration...-Wilmington, PA-NJ-DE fine particulate matter (PM2.5) nonattainment area has attained the 2006 24-hour PM2.5...

  9. 40 CFR 60.1815 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flue gases at the inlet of my particulate matter control device? 60.1815 Section 60.1815 Protection of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You... flue gas stream at the inlet of each particulate matter control device. ...

  10. 40 CFR 60.1815 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... flue gases at the inlet of my particulate matter control device? 60.1815 Section 60.1815 Protection of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You... flue gas stream at the inlet of each particulate matter control device. ...

  11. 40 CFR 62.15270 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... flue gases at the inlet of my particulate matter control device? 62.15270 Section 62.15270 Protection....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...

  12. 40 CFR 62.15270 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flue gases at the inlet of my particulate matter control device? 62.15270 Section 62.15270 Protection....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...

  13. 40 CFR 89.109 - Maintenance instructions and minimum allowable maintenance intervals.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Turbocharger. (iii) Electronic engine control unit and its associated sensors and actuators. (iv) Particulate... emission control and whose function is not integral to the design and performance of the engine). (d... once before the low-hour emission test point. Any other engine, emission control system, or fuel system...

  14. 40 CFR 89.109 - Maintenance instructions and minimum allowable maintenance intervals.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Turbocharger. (iii) Electronic engine control unit and its associated sensors and actuators. (iv) Particulate... emission control and whose function is not integral to the design and performance of the engine). (d... once before the low-hour emission test point. Any other engine, emission control system, or fuel system...

  15. 40 CFR 89.109 - Maintenance instructions and minimum allowable maintenance intervals.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Turbocharger. (iii) Electronic engine control unit and its associated sensors and actuators. (iv) Particulate... emission control and whose function is not integral to the design and performance of the engine). (d... once before the low-hour emission test point. Any other engine, emission control system, or fuel system...

  16. 40 CFR 52.776 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter...: Particulate matter. Link to an amendment published at 78 FR 28507, May 15, 2013. (a) The requirements of... the secondary standards for particulate matter in the Metropolitan Indianapolis Intrastate Region. (b...

  17. 40 CFR 52.2276 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: Particulate matter. 52.2276 Section 52.2276 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....2276 Control strategy and regulations: Particulate matter. (a) Part D conditional approval. The Texas... of the fabric filters, Parker Brothers and Co., Inc., shall not emit particulate matter in excess of...

  18. 40 CFR 52.1781 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1781 Section 52.1781 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.1781 Control strategy: Sulfur oxides and particulate matter. (a) The plan's control strategy...

  19. 40 CFR 52.1781 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1781 Section 52.1781 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.1781 Control strategy: Sulfur oxides and particulate matter. (a) The plan's control strategy...

  20. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter in...

  1. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... National Ambient Air Quality Standards for particulate matter. (1) NAQR Article 7.2.7, Particulate Matter; Table 4.2, Emissions Inventory Summary for Particulates and Table 5.2, Summary of Control Strategy... 24, 1979. (2) Nevada Air Quality Regulations, Article 4, Rule 4.34, (Visible Emission from Stationary...

  2. 40 CFR 52.776 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for attainment and maintenance of the secondary standards for particulate matter in the...

  3. 40 CFR 52.776 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for attainment and maintenance of the secondary standards for particulate matter in the...

  4. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter in...

  5. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter in...

  6. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter in...

  7. 40 CFR 52.227 - Control strategy and regulations: Particulate matter, Metropolitan Los Angeles Intrastate Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: Particulate matter, Metropolitan Los Angeles Intrastate Region. 52.227 Section 52.227 Protection of... IMPLEMENTATION PLANS California § 52.227 Control strategy and regulations: Particulate matter, Metropolitan Los... does not provide for attainment and maintenance of the secondary standards for particulate matter in...

  8. 40 CFR 52.227 - Control strategy and regulations: Particulate matter, Metropolitan Los Angeles Intrastate Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: Particulate matter, Metropolitan Los Angeles Intrastate Region. 52.227 Section 52.227 Protection of... IMPLEMENTATION PLANS California § 52.227 Control strategy and regulations: Particulate matter, Metropolitan Los... does not provide for attainment and maintenance of the secondary standards for particulate matter in...

  9. Sedimentary particulate iron: the missing micronutrients ?

    NASA Astrophysics Data System (ADS)

    Beghoura, Houda; Gorgues, Thomas; Aumont, Olivier; Planquette, Hélène

    2017-04-01

    Iron is known to regulate the marine primary production and to impact the structure of ecosystems. Indeed, iron is the limiting nutrient for the phytoplankton growth over about 30% of the global ocean. However, the nature of the external sources of iron to the ocean and their quantification remain uncertain. Among these external sources, the sediment sources have been recently shown to be underestimated. Besides, since the operationally defined dissolved iron (which is the sum of truly dissolved and colloidal iron) was traditionally assumed to be the only form available to phytoplankton and bacteria, most studies have focused on the supply of dissolved iron to the ocean, the role of the particulate fraction of iron being largely ignored. This traditional view has been recently challenged, noticeably, by observational evidences. Indeed, in situ observations have shown that large amounts of particulate iron are being resuspended from continental margins to the open ocean thanks to fine grained particles' transport over long distances. A fraction of this particulate iron may dissolve and thereby fuel the phytoplankton growth. The magnitude of the sedimentary sources of particulate iron and the releasing processes affecting this iron phase are not yet well constrained or quantified. As a consequence, the role of sedimentary particulate iron in the biogeochemical cycles is still unclear despite its potentially major widespread importance. Here, we propose a modeling exercise to assess the first order impacts of this newly considered particulate sedimentary iron on global ocean biogeochemistry. We designed global experiments with a coupled dynamical-biogeochemical model (NEMO-PISCES). First, a control simulation that includes only a sediment source of iron in the dissolved phase has been run. Then, this control simulation is being compared with simulations, in which we include a sediment source of iron in both phases (dissolved as well as particulate). Those latter simulations have been performed using a range of particulate iron dissolution rates (from published studies and laboratory experiment results) that will permit to test the sensitivity of the biogeochemical response.

  10. 40 CFR 60.58b - Compliance and performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... demonstrated municipal waste combustor unit load shall be the highest 4-hour arithmetic average load achieved... shall be the highest 4-hour arithmetic average temperature achieved at the particulate matter control...

  11. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  12. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  13. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  14. 40 CFR 52.1081 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...

  15. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  16. 40 CFR 52.1131 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March 30...

  17. 40 CFR 52.1131 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March 30...

  18. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  19. 40 CFR 52.1081 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...

  20. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  1. 40 CFR 52.1131 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March 30...

  2. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  3. 40 CFR 52.1081 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...

  4. 40 CFR 52.1081 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...

  5. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  6. 40 CFR 52.1081 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...

  7. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  8. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...

  9. Control of polysilicon on-film particulates with on-product measurements

    NASA Astrophysics Data System (ADS)

    Barker, Judith B.; Chain, Elizabeth E.; Plachecki, Vincent E.

    1997-08-01

    Historically, a number of in-line particle measurements have been performed on separate test wafers included with product wafers during polysilicon processes. By performing film thickness and particulate measurements directly on product wafers, instead, a number of benefits accrue: (1) reduced test wafer usage, (2) reduced test wafer storage requirements, (3) reduced need for equipment to reclaim test wafers, (4) reduced need for direct labor to reclaim test wafers, and (5) reduced engineering 'false alarms' due to incorrectly processed test wafers. Implementation of on-product measurements for the polysilicon diffusion process required a number of changes in both philosophy and methodology. We show the necessary steps to implementation of on-product particle measurements with concern for overall manufacturing efficiency and the need to maintain appropriate control. Particle results from the Tencor 7600 Surfscan are presented.

  10. 40 CFR 52.427 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) Determination of attainment. EPA has determined, as of May 16, 2012, that based on... fine particulate matter (PM2.5) nonattainment area has attained the 2006 24-hour PM2.5 national ambient...

  11. 40 CFR 52.427 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) Determination of attainment. EPA has determined, as of May 16, 2012, that based on... fine particulate matter (PM2.5) nonattainment area has attained the 2006 24-hour PM2.5 national ambient...

  12. 40 CFR 52.2526 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...

  13. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...

  14. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification to...

  15. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...

  16. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...

  17. 40 CFR 52.1341 - Control strategy: particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: particulate matter. 52.1341 Section 52.1341 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: particulate matter. Determination of Attainment. EPA has determined, as of May 23, 2011...

  18. 40 CFR 52.2526 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...

  19. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification to...

  20. 40 CFR 52.2526 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...

  1. 40 CFR 52.2526 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...

  2. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...

  3. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...

  4. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification to...

  5. 40 CFR 52.1341 - Control strategy: particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: particulate matter. 52.1341 Section 52.1341 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: particulate matter. Determination of Attainment. EPA has determined, as of May 23, 2011...

  6. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification to...

  7. 40 CFR 52.2526 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...

  8. PROCEEDINGS: EIGHTH SYMPOSIUM ON THE TRANSFER AND UTILIZATION OF PARTICULATE CONTROL TECHNOLOGY - VOLUME 1. ELECTROSTATIC PRECIPITATORS

    EPA Science Inventory

    The two-volume proceedings describe the latest research and development efforts to improve particulate control devices, while treating traditional concerns of operational cost and compliance. Overall, particulate control remains a key issue in the cost and applicability of furnac...

  9. 40 CFR 52.2678 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy and regulations: Particulate matter. 52.2678 Section 52.2678 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....2678 Control strategy and regulations: Particulate matter. (a) The requirements of § 51.110(a) and...

  10. 40 CFR 52.2678 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy and regulations: Particulate matter. 52.2678 Section 52.2678 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....2678 Control strategy and regulations: Particulate matter. (a) The requirements of § 51.110(a) and...

  11. 40 CFR 52.275 - Particulate matter control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Particulate matter control. 52.275 Section 52.275 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.275 Particulate matter control. (a) The following rules or portions of rules...

  12. 40 CFR 52.275 - Particulate matter control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Particulate matter control. 52.275 Section 52.275 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.275 Particulate matter control. (a) The following rules or portions of rules...

  13. 40 CFR 52.275 - Particulate matter control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Particulate matter control. 52.275 Section 52.275 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.275 Particulate matter control. (a) The following rules or portions of rules...

  14. 40 CFR 52.275 - Particulate matter control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Particulate matter control. 52.275 Section 52.275 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.275 Particulate matter control. (a) The following rules or portions of rules...

  15. PROCEEDINGS: SEVENTH SYMPOSIUM ON THE TRANSFER AND UTILIZATION OF PARTICULATE CONTROL TECHNOLOGY. VOLUME 1

    EPA Science Inventory

    The proceedings document presentations from the seventh symposium on the transfer and utilization of particulate control technology, March 22-25, 1988, in Nashville, TN. Objectives of the symposium were to encourage the exchange of new knowledge in the particulate control field b...

  16. 40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...

  17. 40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. In a letter dated January 30...

  18. 40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...

  19. 40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...

  20. 40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...

  1. 40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. In a letter dated January 30...

  2. 40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. (a) In a letter dated January 30...

  3. 40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...

  4. 40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...

  5. 40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. In a letter dated January 30...

  6. 40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...

  7. 40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. (a) In a letter dated January 30...

  8. 40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...

  9. 40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...

  10. 40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    A test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPs) was conducted . Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical characterization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions. Field testing was conducted in twomore » phases. The Phase I field program was performed over the period of August 24 through September 20, 1992, at the Tennessee Valley Authority Widows Creek Unit 8 Power Station, located near Stevenson (Jackson County), Alabama, on the Tennessee River. Sampling activities for Phase II were conducted from September 11 through October 14, 1993. Widows Creek Unit 8 is a 575-megawatt plant that uses bituminous coal averaging 3.7% sulfur and 13% ash. Downstream of the boiler, a venture wet scrubbing system is used for control of both sulfur dioxide and particulate emissions. There is no electrostatic precipitator (ESP) in this system. This system is atypical and represents only about 5% of the US utility industry. However, this site was chosen for this study because of the lack of information available for this particulate emission control system.« less

  12. Summary of performance data for technologies to control gaseous, odor, and particulate emissions from livestock operations: Air management practices assessment tool (AMPAT)

    PubMed Central

    Maurer, Devin L.; Koziel, Jacek A.; Harmon, Jay D.; Hoff, Steven J.; Rieck-Hinz, Angela M.; Andersen, Daniel S.

    2016-01-01

    The livestock and poultry production industry, regulatory agencies, and researchers lack a current, science-based guide and data base for evaluation of air quality mitigation technologies. Data collected from science-based review of mitigation technologies using practical, stakeholders-oriented evaluation criteria to identify knowledge gaps/needs and focuses for future research efforts on technologies and areas with the greatest impact potential is presented in the Literature Database tab on the air management practices tool (AMPAT). The AMPAT is web-based (available at www.agronext.iastate.edu/ampat) and provides an objective overview of mitigation practices best suited to address odor, gaseous, and particulate matter (PM) emissions at livestock operations. The data was compiled into Excel spreadsheets from a literature review of 265 papers was performed to (1) evaluate mitigation technologies performance for emissions of odor, volatile organic compounds (VOCs), ammonia (NH3), hydrogen sulfide (H2S), particulate matter (PM), and greenhouse gases (GHGs) and to (2) inform future research needs. PMID:27158660

  13. Air cleaning performance of a new environmentally controlled primary crusher operator booth.

    PubMed

    Organiscak, J A; Cecala, A B; Zimmer, J A; Holen, B; Baregi, J R

    2016-02-01

    The National Institute for Occupational Safety and Health (NIOSH) cooperated with 3M Company in the design and testing of a new environmentally controlled primary crusher operator booth at the company's Wausau granite quarry near Wausau, WI. This quarry had an older crusher booth without a central heating, ventilation and air conditioning (HVAC) system, and without an air filtration and pressurization system. A new replacement operator booth was designed and installed by 3M based on design considerations from past NIOSH research on enclosed cab filtration systems. NIOSH conducted pre-testing of the old booth and post-testing of the new booth to assess the new filtration and pressurization system's effectiveness in controlling airborne dusts and particulates. The booth's dust and particulate control effectiveness is described by its protection factor, expressed as a ratio of the outside to inside concentrations measured during testing. Results indicate that the old booth provided negligible airborne respirable dust protection and low particulate protection from the outside environment. The newly installed booth provided average respirable dust protection factors from 2 to 25 over five shifts of dust sampling with occasional worker ingress and egress from the booth, allowing some unfiltered contaminants to enter the enclosure. Shorter-term particle count testing outside and inside the booth under near-steady-state conditions, with no workers entering or exiting the booth, resulted in protection factors from 35 to 127 on 0.3- to 1.0-μm respirable size particulates under various HVAC airflow operating conditions.

  14. Environmental Verification Experiment for the Explorer Platform (EVEEP)

    NASA Technical Reports Server (NTRS)

    Norris, Bonnie; Lorentson, Chris

    1992-01-01

    Satellites and long-life spacecraft require effective contamination control measures to ensure data accuracy and maintain overall system performance margins. Satellite and spacecraft contamination can occur from either molecular or particulate matter. Some of the sources of the molecular species are as follows: mass loss from nonmetallic materials; venting of confined spacecraft or experiment volumes; exhaust effluents from attitude control systems; integration and test activities; and improper cleaning of surfaces. Some of the sources of particulates are as follows: leaks or purges which condense upon vacuum exposure; abrasion of movable surfaces; and micrometeoroid impacts. The Environmental Verification Experiment for the Explorer Platform (EVEEP) was designed to investigate the following aspects of spacecraft contamination control: materials selection; contamination modeling of existing designs; and thermal vacuum testing of a spacecraft with contamination monitors.

  15. PARTICULATE EMISSION MEASUREMENTS FROM CONTROLLED CONSTRUCTION ACTIVITIES

    EPA Science Inventory

    The report summarized the results of field testing of the effectiveness of control measures for sources of fugitive particulate emissions found at construction sites. The effectiveness of watering temporary, unpaved travel surfaces on emissions of particulate matter with aerodyna...

  16. 40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control Strategy: Sulfur oxides and... Strategy: Sulfur oxides and particulate matter. Link to an amendment published at 76 FR 31859, June 2, 2011... user, the added text is set forth as follows: § 52.578 Control Strategy: Sulfur oxides and particulate...

  17. TREATMENT PLANT EVALUATION FOR PARTICULATE CONTAMINANT REMOVAL

    EPA Science Inventory

    A general procedure is suggested for evaluating performance of water filtration plants. Plant operating records should be reviewed. Plant hydraulics should be evaluated. Chemical feed pumps, measuring, and additional points, plus control of chemical doses, are discussed. Rapid mi...

  18. Evolution and current understanding of physicochemical characterization of particulate matter from reactivity controlled compression ignition combustion on a multicylinder light-duty engine

    DOE PAGES

    Storey, John Morse; Curran, Scott J.; Lewis, Samuel A.; ...

    2016-08-04

    Low-temperature compression ignition combustion can result in nearly smokeless combustion, as indicated by a smoke meter or other forms of soot measurement that rely on absorbance due to elemental carbon content. Highly premixed low-temperature combustion modes do not form particulate matter in the traditional pathways seen with conventional diesel combustion. Previous research into reactivity controlled compression ignition particulate matter has shown, despite a near zero smoke number, significant mass can be collected on filter media used for particulate matter certification measurement. In addition, particulate matter size distributions reveal that a fraction of the particles survive heated double-dilution conditions. This papermore » summarizes research completed at Oak Ridge National Laboratory to date on characterizing the nature, chemistry and aftertreatment considerations of reactivity controlled compression ignition particulate matter and presents new research highlighting the importance of injection strategy and fuel composition on reactivity controlled compression ignition particulate matter formation. Particle size measurements and the transmission electron microscopy results do show the presence of soot particles; however, the elemental carbon fraction was, in many cases, within the uncertainty of the thermal–optical measurement. Particulate matter emitted during reactivity controlled compression ignition operation was also collected with a novel sampling technique and analyzed by thermal desorption or pyrolysis gas chromatography mass spectroscopy. Particulate matter speciation results indicated that the high boiling range of diesel hydrocarbons was likely responsible for the particulate matter mass captured on the filter media. Finally, to investigate potential fuel chemistry effects, either ethanol or biodiesel were incorporated to assess whether oxygenated fuels may enhance particle emission reduction.« less

  19. Evolution and current understanding of physicochemical characterization of particulate matter from reactivity controlled compression ignition combustion on a multicylinder light-duty engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Storey, John Morse; Curran, Scott J.; Lewis, Samuel A.

    Low-temperature compression ignition combustion can result in nearly smokeless combustion, as indicated by a smoke meter or other forms of soot measurement that rely on absorbance due to elemental carbon content. Highly premixed low-temperature combustion modes do not form particulate matter in the traditional pathways seen with conventional diesel combustion. Previous research into reactivity controlled compression ignition particulate matter has shown, despite a near zero smoke number, significant mass can be collected on filter media used for particulate matter certification measurement. In addition, particulate matter size distributions reveal that a fraction of the particles survive heated double-dilution conditions. This papermore » summarizes research completed at Oak Ridge National Laboratory to date on characterizing the nature, chemistry and aftertreatment considerations of reactivity controlled compression ignition particulate matter and presents new research highlighting the importance of injection strategy and fuel composition on reactivity controlled compression ignition particulate matter formation. Particle size measurements and the transmission electron microscopy results do show the presence of soot particles; however, the elemental carbon fraction was, in many cases, within the uncertainty of the thermal–optical measurement. Particulate matter emitted during reactivity controlled compression ignition operation was also collected with a novel sampling technique and analyzed by thermal desorption or pyrolysis gas chromatography mass spectroscopy. Particulate matter speciation results indicated that the high boiling range of diesel hydrocarbons was likely responsible for the particulate matter mass captured on the filter media. Finally, to investigate potential fuel chemistry effects, either ethanol or biodiesel were incorporated to assess whether oxygenated fuels may enhance particle emission reduction.« less

  20. Conduction and Narrow Escape in Dense, Disordered, Particulate-based Heterogeneous Materials

    NASA Astrophysics Data System (ADS)

    Lechman, Jeremy

    For optimal and reliable performance, many technological devices rely on complex, disordered heterogeneous or composite materials and their associated manufacturing processes. Examples include many powder and particulate-based materials found in phyrotechnic devices for car airbags, electrodes in energy storage devices, and various advanced composite materials. Due to their technological importance and complex structure, these materials have been the subject of much research in a number of fields. Moreover, the advent of new manufacturing techniques based on powder bed and particulate process routes, the potential of functional nano-structured materials, and the additional recognition of persistent shortcomings in predicting reliable performance of high consequence applications; leading to ballooning costs of fielding and maintaining advanced technologies, should motivate renewed efforts in understanding, predicting and controlling these materials' fabrication and behavior. Our particular effort seeks to understand the link between the top-down control presented in specific non-equilibrium processes routes (i.e., manufacturing processes) and the variability and uncertainty of the end product performance. Our ultimate aim is to quantify the variability inherent in these constrained dynamical or random processes and to use it to optimize and predict resulting material properties/performance and to inform component design with precise margins. In fact, this raises a set of deep and broad-ranging issues that have been recognized and as touching the core of a major research challenge at Sandia National Laboratories. In this talk, we will give an overview of recent efforts to address aspects of this vision. In particular the case of conductive properties of packed particulate materials will be highlighted. Combining a number of existing approaches we will discuss new insights and potential directions for further development toward the stated goal. Sandia National Laboratories is a multiprogram laboratory managed and operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy's National Nuclear Security Administration under Contract No. DE-AC04-94AL85000.

  1. Particulate Emissions Control using Advanced Filter Systems: Final Report for Argonne National Laboratory, Corning Inc. and Hyundai Motor Company CRADA Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seong, Hee Je; Choi, Seungmok

    2015-10-09

    This is a 3-way CRADA project working together with Corning, Inc. and Hyundai Motor Co. (HMC). The project is to understand particulate emissions from gasoline direct-injection engines (GDI) and their physico-chemical properties. In addition, this project focuses on providing fundamental information about filtration and regeneration mechanisms occurring in gasoline particulate filter (GPF) systems. For the work, Corning provides most advanced filter substrates for GPF applications and HMC provides three-way catalyst (TWC) coating services of these filter by way of a catalyst coating company. Then, Argonne National Laboratory characterizes fundamental behaviors of filtration and regeneration processes as well as evaluated TWCmore » functionality for the coated filters. To examine aging impacts on TWC and GPF performance, the research team evaluates gaseous and particulate emissions as well as back-pressure increase with ash loading by using an engine-oil injection system to accelerate ash loading in TWC-coated GPFs.« less

  2. 40 CFR 60.45c - Compliance and performance test methods and procedures for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Compliance and performance test methods and procedures for particulate matter. 60.45c Section 60.45c Protection of Environment ENVIRONMENTAL... Compliance and performance test methods and procedures for particulate matter. (a) The owner or operator of...

  3. 40 CFR 52.427 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.427 Section 52.427 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. Determination of attainment. EPA has determined, as of May 16, 2012, that based on 2007 to...

  4. 40 CFR 52.332 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...

  5. 40 CFR 52.332 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...

  6. 40 CFR 52.332 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...

  7. 40 CFR 52.332 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...

  8. 40 CFR 52.332 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shao, Huifang; Lam, William; Remias, Joseph

    Mobile source emissions standards are becoming more stringent and particulate emissions from gasoline direct injection (GDI) engines represent a particular challenge. Gasoline particulate filter (GPF) is deemed as one possible technical solution for particulate emissions reduction. In this work, a study was conducted on eight formulations of lubricants to determine their effect on GDI engine particulate emissions and GPF performance. Accelerated ash loading tests were conducted on a 2.4L GDI engine with engine oil injection in gasoline fuel by 2%. The matrix of eight formulations was designed with changing levels of sulfated ash (SASH) level, Zinc dialkyldithiophosphates (ZDDP) level andmore » detergent type. Comprehensive evaluations of particulates included mass, number, size distribution, composition, morphology and soot oxidation properties. GPF performance was assessed through filtration efficiency, back pressure and morphology. It was determined that oil formulation affects the particulate emission characteristics and subsequent GPF performance.« less

  10. 40 CFR 60.285a - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... performance test. (b) The owner or operator must determine compliance with the filterable particulate matter... used to determine the filterable particulate matter concentration. The sampling time and sample volume... repeat performance tests for filterable particulate matter at intervals no longer than 5 years following...

  11. 40 CFR 60.422 - Standards for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for particulate matter. 60... Manufacture § 60.422 Standards for particulate matter. On or after the date on which the performance test... sulfate dryer, particulate matter at an emission rate exceeding 0.15 kilogram of particulate per megagram...

  12. 40 CFR 60.422 - Standards for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for particulate matter. 60... Manufacture § 60.422 Standards for particulate matter. On or after the date on which the performance test... sulfate dryer, particulate matter at an emission rate exceeding 0.15 kilogram of particulate per megagram...

  13. 40 CFR 60.422 - Standards for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for particulate matter. 60... Manufacture § 60.422 Standards for particulate matter. On or after the date on which the performance test... sulfate dryer, particulate matter at an emission rate exceeding 0.15 kilogram of particulate per megagram...

  14. 40 CFR 60.422 - Standards for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for particulate matter. 60... Manufacture § 60.422 Standards for particulate matter. On or after the date on which the performance test... sulfate dryer, particulate matter at an emission rate exceeding 0.15 kilogram of particulate per megagram...

  15. Air cleaning performance of a new environmentally controlled primary crusher operator booth

    PubMed Central

    Organiscak, J.A.; Cecala, A.B.; Zimmer, J.A.; Holen, B.; Baregi, J.R.

    2016-01-01

    The National Institute for Occupational Safety and Health (NIOSH) cooperated with 3M Company in the design and testing of a new environmentally controlled primary crusher operator booth at the company’s Wausau granite quarry near Wausau, WI. This quarry had an older crusher booth without a central heating, ventilation and air conditioning (HVAC) system, and without an air filtration and pressurization system. A new replacement operator booth was designed and installed by 3M based on design considerations from past NIOSH research on enclosed cab filtration systems. NIOSH conducted pre-testing of the old booth and post-testing of the new booth to assess the new filtration and pressurization system’s effectiveness in controlling airborne dusts and particulates. The booth’s dust and particulate control effectiveness is described by its protection factor, expressed as a ratio of the outside to inside concentrations measured during testing. Results indicate that the old booth provided negligible airborne respirable dust protection and low particulate protection from the outside environment. The newly installed booth provided average respirable dust protection factors from 2 to 25 over five shifts of dust sampling with occasional worker ingress and egress from the booth, allowing some unfiltered contaminants to enter the enclosure. Shorter-term particle count testing outside and inside the booth under near-steady-state conditions, with no workers entering or exiting the booth, resulted in protection factors from 35 to 127 on 0.3- to 1.0-μm respirable size particulates under various HVAC airflow operating conditions. PMID:26937052

  16. 40 CFR 52.1880 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because the... matter in the Greater Metropolitan Cleveland Intrastate Region and the Ohio portions of the Northwest...

  17. 40 CFR 52.1880 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because the... matter in the Greater Metropolitan Cleveland Intrastate Region and the Ohio portions of the Northwest...

  18. 40 CFR 52.1880 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because the... matter in the Greater Metropolitan Cleveland Intrastate Region and the Ohio portions of the Northwest...

  19. 40 CFR 52.1880 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because the... matter in the Greater Metropolitan Cleveland Intrastate Region and the Ohio portions of the Northwest...

  20. 40 CFR 52.933 - Control Strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.933 Section 52.933 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. (a) In a letter dated March 27, 1987, the Kentucky...

  1. 40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.578 Section 52.578 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 26, 1987, the Georgia Department of...

  2. 40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.578 Section 52.578 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 26, 1987, the Georgia Department of...

  3. 40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.578 Section 52.578 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 26, 1987, the Georgia Department of...

  4. 40 CFR 52.933 - Control Strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.933 Section 52.933 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 27, 1987, the Kentucky Department...

  5. 40 CFR 52.62 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.62 Section 52.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... strategy: Sulfur oxides and particulate matter. In a letter dated May 29, 1987, the Alabama Department of...

  6. 40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.578 Section 52.578 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 26, 1987, the Georgia Department of...

  7. 40 CFR 62.15270 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...

  8. 40 CFR 62.15270 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...

  9. 40 CFR 62.15270 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...

  10. Controlling soot formation with filtered EGR for diesel and biodiesel fuelled engines.

    PubMed

    Gill, S S; Turner, D; Tsolakis, A; York, A P E

    2012-04-03

    Although exhaust gas recirculation (EGR) is an effective strategy for controlling the levels of nitrogen oxides (NO(X)) emitted from a diesel engine, the full potential of EGR in NO(X)/PM trade-off and engine performance (i.e., fuel economy) has not fully been exploited. Significant work into the cause and control of particulate matter (PM) has been made over the past decade with new cleaner fuels and after-treatment devices emerging to comply with the current and forthcoming emission regulations. In earlier work, we demonstrated that engine operation with oxygenated fuels (e.g., biodiesel) reduces the PM emissions and extends the engine tolerance to EGR before it reaches smoke-limited conditions. The same result has also been reported when high cetane number fuels such as gas-to-liquid (GTL) are used. To further our understanding of the relationship between EGR and PM formation, a diesel particulate filter (DPF) was integrated into the EGR loop to filter the recirculated soot particulates. The control of the soot recirculation penalty through filtered EGR (FEGR) resulted in a 50% engine-out soot reduction, thus showing the possibility of extending the maximum EGR limit or being able to run at the same level of EGR with an improved NO(X)/soot trade-off.

  11. 40 CFR 60.46b - Compliance and performance test methods and procedures for particulate matter and nitrogen oxides.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Compliance and performance test methods and procedures for particulate matter and nitrogen oxides. 60.46b Section 60.46b Protection of... Generating Units § 60.46b Compliance and performance test methods and procedures for particulate matter and...

  12. 40 CFR 60.2720 - May I conduct performance testing less often?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen chloride, or...) If your CISWI unit continues to meet the emission limitation for particulate matter, hydrogen... shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or opacity, you...

  13. A laboratory comparison of evacuation devices on aerosol reduction.

    PubMed

    Jacks, Mary E

    2002-01-01

    Aerosols are defined as airborne particles that range in size from 0.5 to 10 microns (micron). They are produced during ultrasonic instrumentation, but they can be reduced. Irrigant solutions, which produce the therapeutic effects of lavage, also combine with blood, saliva, and bacteria to produce potentially harmful airborne particulates. The American Dental Association (ADA) and the Centers for Disease Control and Prevention (CDC) recommend utilization of high volume evacuation, rubber dam, and patient positioning for aerosol control. But for the non-assisted dental hygienist, these recommendations are difficult to implement. This study was designed to compare the concentration of airborne particulates from ultrasonic scaling, utilizing three different methods of evacuation. In a laboratory setting, ultrasonic airborne particulates were generated utilizing a 25,000 cps magnetostrictive ultrasonic scaling instrument. Three evacuation devises were compared for effectiveness: a standard saliva ejector intraorally positioned; and two extraorally positioned, hands-free high-volume evacuation (HFHVE) techniques. One of these devices had a standard attachment, and, the other had a funnel-shaped attachment. Measurement of airborne particles was performed with a DataRAM Real-Time Aerosol Monitor. This study (N = 21) found a significant reduction in the number of airborne particulates with either form of extraoral HFHVE attachment in place. Standard attachments and funnel-shaped attachments to HFHVE resulted in reduction of particulates by 90.8% and 89.7%, respectively, when compared to the intraorally positioned standard saliva ejector. Utilizing either form of HFHVE during ultrasonic instrumentation significantly reduced the number of aerosolized particulates that reached the breathing space of the client and clinician. This lends support for the ADA and CDC recommendation that HVE be used during aerosol producing procedures. Currently, no preventive measure is 100% effective; therefore, clinicians are encouraged to use additional methods to minimize the number of airborne particulates produced during intraoral instrumentation.

  14. 40 CFR 60.472 - Standards for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.472 Standards for particulate matter. (a) On and after the...) Particulate matter in excess of: (i) 0.04 kg/Mg (0.08 lb/ton) of asphalt shingle or mineral-surfaced roll...

  15. 40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...

  16. 40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...

  17. 40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...

  18. 40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...

  19. 40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...

  20. 30 CFR 57.5066 - Maintenance standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., Physical Agents, and Diesel Particulate Matter Diesel Particulate Matter-Underground Only § 57.5066... manufacturer specifications; and (3) The operator must maintain any emission or particulate control device...

  1. 30 CFR 57.5066 - Maintenance standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Physical Agents, and Diesel Particulate Matter Diesel Particulate Matter-Underground Only § 57.5066... manufacturer specifications; and (3) The operator must maintain any emission or particulate control device...

  2. 40 CFR 52.228 - Regulations: Particulate matter, Southeast Desert Intrastate Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Regulations: Particulate matter... § 52.228 Regulations: Particulate matter, Southeast Desert Intrastate Region. (a) The following... particulate matter in the Southeast Desert Intrastate Region. (1) Imperial County Air Pollution Control...

  3. 40 CFR 52.228 - Regulations: Particulate matter, Southeast Desert Intrastate Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Regulations: Particulate matter... § 52.228 Regulations: Particulate matter, Southeast Desert Intrastate Region. (a) The following... particulate matter in the Southeast Desert Intrastate Region. (1) Imperial County Air Pollution Control...

  4. Methods and apparatus for handling or treating particulate material

    NASA Technical Reports Server (NTRS)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2009-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  5. 40 CFR 52.126 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: Particulate matter. 52.126 Section 52.126 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... strategy and regulations: Particulate matter. (a) The requirements of subpart G and § 51.281 of this... the national standards for particulate matter in Gila, Maricopa, Pima, Pinal, and Santa Cruz Counties...

  6. 40 CFR 52.1781 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and... Carolina § 52.1781 Control strategy: Sulfur oxides and particulate matter. (a) The plan's control strategy... State expects the resulting emission reductions of nitrogen oxides and sulfur dioxide from this control...

  7. 40 CFR 52.1781 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and... Carolina § 52.1781 Control strategy: Sulfur oxides and particulate matter. (a) The plan's control strategy... State expects the resulting emission reductions of nitrogen oxides and sulfur dioxide from this control...

  8. 40 CFR 52.1781 - Control strategy: Sulfur oxides and particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and... Carolina § 52.1781 Control strategy: Sulfur oxides and particulate matter. (a) The plan's control strategy... State expects the resulting emission reductions of nitrogen oxides and sulfur dioxide from this control...

  9. Control Techniques for Particulate Air Pollutants.

    ERIC Educational Resources Information Center

    National Air Pollution Control Administration (DHEW), Washington, DC.

    Included is a comprehensive review of the approaches commonly recommended for controlling the sources of particulate air pollution. Not all possible combinations of control techniques that might bring about more stringent control of each individual source are reviewed. The many agricultural, commercial, domestic, industrial, and municipal…

  10. Method of making polymer powders and whiskers as well as particulate products of the method and atomizing apparatus

    DOEpatents

    Otaigbe, Joshua U.; McAvoy, Jon M.; Anderson, Iver E.; Ting, Jason; Mi, Jia; Terpstra, Robert

    2001-01-09

    Method for making polymer particulates, such as spherical powder and whiskers, by melting a polymer material under conditions to avoid thermal degradation of the polymer material, atomizing the melt using gas jet means in a manner to form atomized droplets, and cooling the droplets to form polymer particulates, which are collected for further processing. Atomization parameters can be controlled to produce polymer particulates with controlled particle shape, particle size, and particle size distribution. For example, atomization parameters can be controlled to produce spherical polymer powders, polymer whiskers, and combinations of spherical powders and whiskers. Atomizing apparatus also is provided for atoomizing polymer and metallic materials.

  11. 40 CFR 60.172 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  12. 40 CFR 60.172 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  13. 40 CFR 60.162 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  14. 40 CFR 60.172 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  15. 40 CFR 60.162 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  16. 40 CFR 60.172 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  17. 40 CFR 60.162 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  18. 40 CFR 60.162 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  19. 40 CFR 60.162 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  20. 40 CFR 60.172 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...

  1. 40 CFR 60.262 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.262... Production Facilities § 60.262 Standard for particulate matter. (a) On and after the date on which the... furnace any gases which: (1) Exit from a control device and contain particulate matter in excess of 0.45...

  2. 40 CFR 60.262 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.262... Production Facilities § 60.262 Standard for particulate matter. (a) On and after the date on which the... furnace any gases which: (1) Exit from a control device and contain particulate matter in excess of 0.45...

  3. 40 CFR 60.262 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.262... Production Facilities § 60.262 Standard for particulate matter. (a) On and after the date on which the... furnace any gases which: (1) Exit from a control device and contain particulate matter in excess of 0.45...

  4. 40 CFR 60.262 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.262... Production Facilities § 60.262 Standard for particulate matter. (a) On and after the date on which the... furnace any gases which: (1) Exit from a control device and contain particulate matter in excess of 0.45...

  5. A review of phosphorus removal structures: How to assess and compare their performance

    USDA-ARS?s Scientific Manuscript database

    Controlling dissolved phosphorus (P) losses to surface waters is challenging as most conservation practices are only effective at preventing particulate P losses. As a result, P removal structures were developed to filter dissolved P from drainage water before reaching a water body. While many P rem...

  6. TI-59 PROGRAMMABLE CALCULATOR PROGRAMS FOR IN-STACK OPACITY, VENTURI SCRUBBERS, AND ELECTROSTATIC PRECIPITATORS

    EPA Science Inventory

    The report explains the basic concepts of in-stack opacity as measured by in-stack opacity monitors. Also included are calculator programs that model the performance of venturi scrubbers and electrostatic precipitators. The effect of particulate control devices on in-stack opacit...

  7. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES: MITSUI ENGINEERING & SHIPBUILDING DIESEL PARTICULATE FILTER

    EPA Science Inventory

    EPA‘s Environmental Technology Verification program is designed to further environmental protection by accelerating the acceptance and use of improved and cost effective technologies. This is done by providing high-quality, peer reviewed data on technology performance to those in...

  8. Removal of residual particulate matter from filter media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almlie, Jay C.; Miller, Stanley J.

    A method for removing residual filter cakes that remain adhered to a filter after typical particulate removal methodologies have been employed, such as pulse-jet filter element cleaning, for all cleanable filters used for air pollution control, dust control, or powder control.

  9. Removal of residual particulate matter from filter media

    DOEpatents

    Almlie, Jay C; Miller, Stanley J

    2014-11-11

    A method for removing residual filter cakes that remain adhered to a filter after typical particulate removal methodologies have been employed, such as pulse-jet filter element cleaning, for all cleanable filters used for air pollution control, dust control, or powder control.

  10. 40 CFR 60.182 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...

  11. 40 CFR 60.52 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...

  12. 40 CFR 60.182 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...

  13. 40 CFR 60.52 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...

  14. 40 CFR 60.52 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...

  15. 40 CFR 60.182 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...

  16. 40 CFR 60.52 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...

  17. 40 CFR 60.52 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...

  18. 40 CFR 60.182 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...

  19. 40 CFR 60.182 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...

  20. Waste Water Treatment Apparatus and Methods

    NASA Technical Reports Server (NTRS)

    Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor); Littman, Howard (Inventor)

    2014-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  1. Economic comparison of fabric filters and electrostatic precipitators for particulate control on coal-fired utility boilers

    NASA Technical Reports Server (NTRS)

    Cukor, P. M.; Chapman, R. A.

    1978-01-01

    The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.

  2. 40 CFR 52.330 - Control strategy: Total suspended particulates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Total suspended particulates. 52.330 Section 52.330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.330 Control strategy...

  3. Mass and number size distributions of emitted particulates at five important operation units in a hazardous industrial waste incineration plant.

    PubMed

    Lin, Chi-Chi; Huang, Hsiao-Lin; Hsiao, Wen-Yuan

    2016-01-01

    Past studies indicated particulates generated by waste incineration contain various hazardous compounds. The aerosol characteristics are very important for particulate hazard control and workers' protection. This study explores the detailed characteristics of emitted particulates from each important operation unit in a rotary kiln-based hazardous industrial waste incineration plant. A dust size analyzer (Grimm 1.109) and a scanning mobility particle sizer (SMPS) were used to measure the aerosol mass concentration, mass size distribution, and number size distribution at five operation units (S1-S5) during periods of normal operation, furnace shutdown, and annual maintenance. The place with the highest measured PM10 concentration was located at the area of fly ash discharge from air pollution control equipment (S5) during the period of normal operation. Fine particles (PM2.5) constituted the majority of the emitted particles from the incineration plant. The mass size distributions (elucidated) made it clear that the size of aerosols caused by the increased particulate mass, resulting from work activities, were mostly greater than 1.5 μm. Whereas the number size distributions showed that the major diameters of particulates that caused the increase of particulate number concentrations, from work activities, were distributed in the sub micrometer range. The process of discharging fly ash from air pollution control equipment can significantly increase the emission of nanoparticles. The mass concentrations and size distributions of emitted particulates were different at each operation unit. This information is valuable for managers to take appropriate strategy to reduce the particulate emission and associated worker exposure.

  4. 40 CFR 52.227 - Control strategy and regulations: Particulate matter, Metropolitan Los Angeles Intrastate Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... IMPLEMENTATION PLANS California § 52.227 Control strategy and regulations: Particulate matter, Metropolitan Los... Los Angeles Intrastate Region. (1) Los Angeles County Air Pollution Control District: (i) Regulation IV, Rule 68.1. (2) Riverside County Air Pollution Control District: (i) Regulation IV, Rule 54 for...

  5. 40 CFR 52.227 - Control strategy and regulations: Particulate matter, Metropolitan Los Angeles Intrastate Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... IMPLEMENTATION PLANS California § 52.227 Control strategy and regulations: Particulate matter, Metropolitan Los... Los Angeles Intrastate Region. (1) Los Angeles County Air Pollution Control District: (i) Regulation IV, Rule 68.1. (2) Riverside County Air Pollution Control District: (i) Regulation IV, Rule 54 for...

  6. 40 CFR 52.227 - Control strategy and regulations: Particulate matter, Metropolitan Los Angeles Intrastate Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... IMPLEMENTATION PLANS California § 52.227 Control strategy and regulations: Particulate matter, Metropolitan Los... Los Angeles Intrastate Region. (1) Los Angeles County Air Pollution Control District: (i) Regulation IV, Rule 68.1. (2) Riverside County Air Pollution Control District: (i) Regulation IV, Rule 54 for...

  7. Review of Leading Approaches for Mitigating Hypersonic Vehicle Communications Blackout and a Method of Ceramic Particulate Injection Via Cathode Spot Arcs for Blackout Mitigation

    NASA Technical Reports Server (NTRS)

    Gillman, Eric D.; Foster, John E.; Blankson, Isaiah M.

    2010-01-01

    Vehicles flying at hypersonic velocities within the atmosphere become enveloped in a "plasma sheath" that prevents radio communication, telemetry, and most importantly, GPS signal reception for navigation. This radio "blackout" period has been a problem since the dawn of the manned space program and was an especially significant hindrance during the days of the Apollo missions. An appropriate mitigation method must allow for spacecraft to ground control and ground control to spacecraft communications through the reentry plasma sheath. Many mitigation techniques have been proposed, including but not limited to, aerodynamic shaping, magnetic windows, and liquid injection. The research performed on these mitigation techniques over the years will be reviewed and summarized, along with the advantages and obstacles that each technique will need to overcome to be practically implemented. A unique approach for mitigating the blackout communications problem is presented herein along with research results associated with this method. The novel method involves the injection of ceramic metal-oxide particulate into a simulated reentry plasma to quench the reentry plasma. Injection of the solid ceramic particulates is achieved by entrainment within induced, energetic cathode spot flows.

  8. Cardiovascular changes in workers exposed to fine particulate dust.

    PubMed

    Bortkiewicz, Alicja; Gadzicka, Elżbieta; Stroszejn-Mrowca, Grażyna; Szyjkowska, Agata; Szymczak, Wiesław; Koszada-Włodarczyk, Wiesława; Szadkowska-Stańczyk, Irena

    2014-01-01

    Epidemiological studies provide evidence that airborne particulate matter may contribute to the increased incidence and mortality rates due to pulmonary and cardiovascular diseases. Only some of them address the problem of occupational exposure to particulate air pollution. The aim of our study was to assess cardiovascular reaction and autonomic regulation in workers exposed to fine particles. All workers had medical examination, resting ECG with heart rate variability analysis (HRV), 24-h ECG, and ambulatory blood pressure monitoring (ABPM) performed. The subjects were 20 male workers (mean age: 32.14.0 year) of a ceramic ware factory exposed to the dust and 20 workers who were not exposed (mean age: 39.4±7.8 year). The period of employment under exposure amounted to 5.6±2.1 year. Dust exposure was measured using individual dosimeters. The geometric mean total dust concentration was 44±1.5 mg/m(3) and the FPD (fine particulate dust) concentration amounted to 11.5±1.6 mg/m(3). No abnormalities were noted in the resting ECG in both groups, in 24-h ECG 2 subjects, both from exposed and control groups, had ventricular heart rhythm and repolarization disturbances. Blood pressure in ABPM, both systolic as well as diastolic, was normal and did not differ between the groups. Resting heart rate in the exposed group was significantly lower (p = 0.038) than in the control group. In the exposed group STD R-R from short-term records was significantly higher (p = 0.01). Fast Fourier Transform (FFT) analysis showed that the low frequency power spectrum (LF) did not differ in the exposed and the control group, while high frequency (HF) was significantly higher in the exposed group. LF/HF ratio was significantly lower in the exposed in comparison with the control group. Although we did not reveal significant abnormalities in ECG as well as in ABPM in the exposed group, it seems that neurovegetative disturbances (parasympathetic predominance) may serve as an early indicator of fine particulate dust effect on cardiovascular system.

  9. 40 CFR 60.122 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...

  10. 40 CFR 60.92 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...

  11. 40 CFR 60.92 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...

  12. 40 CFR 60.122 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...

  13. 40 CFR 60.92 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...

  14. 40 CFR 60.122 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...

  15. 40 CFR 60.152 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...

  16. 40 CFR 60.152 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...

  17. 40 CFR 60.92 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...

  18. 40 CFR 60.122 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...

  19. 40 CFR 60.122 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...

  20. 40 CFR 60.152 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...

  1. 40 CFR 60.92 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...

  2. 40 CFR 60.152 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...

  3. 40 CFR 60.152 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...

  4. Advanced Hybrid Particulate Collector Project Management Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, S.J.

    As the consumption of energy increases, its impact on ambient air quality has become a significant concern. Recent studies indicate that fine particles from coal combustion cause health problems as well as atmospheric visibility impairment. These problems are further compounded by the concentration of hazardous trace elements such as mercury, cadmium, selenium, and arsenic in fine particles. Therefore, a current need exists to develop superior, but economical, methods to control emissions of fine particles. Since most of the toxic metals present in coal will be in particulate form, a high level of fine- particle collection appears to be the bestmore » method of overall air toxics control. However, over 50% of mercury and a portion of selenium emissions are in vapor form and cannot be collected in particulate control devices. Therefore, this project will focus on developing technology not only to provide ultrahigh collection efficiency of particulate air toxic emissions, but also to capture vapor- phase trace metals such as mercury and selenium. Currently, the primary state-of-the-art technologies for particulate control are fabric filters (baghouses) and electrostatic precipitators (ESPs). However, they both have limitations that prevent them from achieving ultrahigh collection of fine particulate matter and vapor-phase trace metals. The objective of this project is to develop a highly reliable advanced hybrid particulate collector (AHPC) that can provide > 99.99 % particulate collection efficiency for all particle sizes between 0.01 and 50 14m, is applicable for use with all U.S. coals, and is cost-0443competitive with existing technologies. Phase I of the project is organized into three tasks: Task I - Project Management, Reporting, and Subcontract Consulting Task 2 - Modeling, Design, and Construction of 200-acfm AHPC Model Task 3 - Experimental Testing and Subcontract Consulting« less

  5. Grain Elevators: New Source Performance Standards (NSPS)

    EPA Pesticide Factsheets

    The New Source Performance Standards (NSPS) for Grain Elevators aims to reduce particulate matter pollution. The new amendments seek to clarify definitions, and requirements, as well as propose new regulations on particulate matter emissions

  6. 40 CFR 52.1783 - Original identification of plan section.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of Particulates from Hot Mix Asphalt Plants 2D.0507—Particulates from Chemical Fertilizer Manufacturing Plants 2D.0508—Control of Particulates from Pulp and Paper Mills 2D.0509—Particulates from Mica or... Emissions from Bulk Gasoline Terminals 2D.0918—Can Coating 2D.0919—Coil Coating 2D.0920—Paper Coating 2D...

  7. 40 CFR 52.1783 - Original identification of plan section.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of Particulates from Hot Mix Asphalt Plants 2D.0507—Particulates from Chemical Fertilizer Manufacturing Plants 2D.0508—Control of Particulates from Pulp and Paper Mills 2D.0509—Particulates from Mica or... Emissions from Bulk Gasoline Terminals 2D.0918—Can Coating 2D.0919—Coil Coating 2D.0920—Paper Coating 2D...

  8. 40 CFR 52.1783 - Original identification of plan section.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of Particulates from Hot Mix Asphalt Plants 2D.0507—Particulates from Chemical Fertilizer Manufacturing Plants 2D.0508—Control of Particulates from Pulp and Paper Mills 2D.0509—Particulates from Mica or... Emissions from Bulk Gasoline Terminals 2D.0918—Can Coating 2D.0919—Coil Coating 2D.0920—Paper Coating 2D...

  9. Cost Effectiveness Of Selected Roadway Dust Control Methods For Eagle River, Alaska

    DOT National Transportation Integrated Search

    1988-01-01

    The U.S. Environmental Protection Agency has set air quality standards for airborne particulates with diameters equal to or less than ten microns (PM10 particulates). These particulates have been correlated with respiratory illnesses. The primary sta...

  10. INTERNATIONAL APPROACHES TO DEVELOPING STANDARDS FOR NONCRITERIA POLLUTANTS

    EPA Science Inventory

    Much of the initial interest in the control of pollutants, both in the United States and abroad, focused on such "traditional" pollutants as sulfur dioxide, particulate matter, Total Suspended Particulate (TSP) and particulate matter, nitrogen oxides, carbon monoxide, ozone, and ...

  11. ENVIRONMENTAL TECHNOLOGY VERIFICATION: TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES--PUREM NORTH AMERICA LLC, PMF GREENTEC 1004205.00.0 DIESEL PARTICULATE FILTER

    EPA Science Inventory

    The U.S. EPA has created the Environmental Technology Verification (ETV) program to provide high quality, peer reviewed data on technology performance to those involved in the design, distribution, financing, permitting, purchase, and use of environmental technologies. The Air Po...

  12. 40 CFR 52.126 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be determined by using method 2 and traversing according to method 1. Gas analysis shall be performed using the integrated sample technique of method 3, and moisture content shall be determined by the condenser technique of method 4. (iii) All tests shall be conducted while the source is operating at the...

  13. Monitoring by Control Technique - Wet Scrubber For Particulate Matter

    EPA Pesticide Factsheets

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about Wet Scrubber For Particulate Matter controls used to reduce pollutant emissions.

  14. Duct having oscillatory side wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sprouse, Kenneth M.

    A pump system includes a particulate consolidator pump that has a pump outlet. A duct is coupled to the pump outlet. The duct has a wall that is coupled with an oscillator. The oscillator is operable to oscillate the wall at a controlled frequency. The controlled frequency is selected with respect to breaking static bridging of particulate in the duct due, at least in part, to consolidation of the particulate from a downstream check valve.

  15. Analysis of airborne particulate matter pollution in Timisoara city urban area and correlations between measurements and meteorological data

    NASA Astrophysics Data System (ADS)

    Lungu, Mihai; Lungu, Antoanetta; Stefu, Nicoleta; Neculae, Adrian; Strambeanu, Nicolae

    2017-01-01

    Air pollution is known to have many adverse effects, among which those on human health are considered the most important. Healthy people of all ages can be adversely affected by high levels of air pollutants. Nanoparticles can be considered among the most harmful of all pollutants as they can penetrate straight into the lungs and blood stream. Their role in the aging process has also recently been revealed. In Romania, practically in all important urban areas (Bucureşti, Iaşi, Timişoara, Braşov, Baia Mare, etc.) the daily limit values for airborne particulate matter are exceeded, so more efforts in controlling air quality are required, along with more research and policies with positive impact on reducing the pollutants concentration in air. The approaches that have been developed to assess the air quality and health impacts of pollution sources are based on analytical methods such as source apportionment, factor analyses, and the measurement of source-relevant indicator compounds. The goal of the present study is to offer preliminary but relevant information on the particulate matter distribution in the city of Timisoara, Romania. Measurements of inhalable coarse and fine particles in two areas of the city, the most affected by industrial particulate emissions, were performed in days with various meteorological conditions. Meteorological parameters for the specific measurement days were recorded (wind speed and direction, humidity, temperature, pressure, etc.) and the influence of these parameters on the particulate matter dispersion was studied. The results show that the meteorological conditions cause differences between airborne particulate matter distributions in different days in the same zones. Measurements were made in northern and southern areas of the city of Timisoara because previous results have shown high levels of airborne particulate matter in these areas.

  16. Research on particulate filter simulation and regeneration control strategy

    NASA Astrophysics Data System (ADS)

    Dawei, Qu; Jun, Li; Yu, Liu

    2017-03-01

    This paper reports a DPF (Diesel Particulate Filter) collection mathematical model for a new regeneration control strategy. The new strategy is composed by main parts, such as regeneration time capturing, temperature rising strategy and regeneration control strategy. In the part of regeneration time capturing, a multi-level regeneration capturing method is put forward based on the combined effect of the PM (Particulate Matter) loading, pressure drop and fuel consumption. The temperature rising strategy proposes the global temperature for all operating conditions. The regeneration control process considers the particle loading density, temperature and oxygen respectively. Based on the analysis of the initial overheating, runaway temperature and local hot spot, the final control strategy is established.

  17. 78 FR 59672 - Draft National Pollutant Discharge Elimination System (NPDES) General Permit for Stormwater...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-27

    ... particulates and other potential pollutants present on pavement, specific effluent limits have been included to ensure particulates and other potential pollutants mobilized by pavement washing are controlled via treatment controls before they are discharged, unless the pavement wash waters were treated by the control...

  18. Environmental Technology Verification, Baghouse Filtration Products TTG Inc., TG800 Filtration Media (Tested August 2012)

    EPA Science Inventory

    Baghouses are air pollution control devices used to control particulate emissions from stationary sources and are among the technologies evaluated by the APCT Center. Baghouses and their accompanying filter media have long been one of the leading particulate control techniques fo...

  19. Donaldson Company, Inc., Dura-Life #0701607 Filtration Media(Tested October 2011) (ETV Baghouse Filtration Products) Verification Report

    EPA Science Inventory

    Baghouses are air pollution control devices used to control particulate emissions from stationary sources and are among the technologies evaluated by the APCT Center. Baghouses and their accompanying filter media have long been one of the leading particulate control techniques fo...

  20. Environmental Technology Verification; Baghouse Filtration Products TTG Inc., TG100 Filtration Media (Tested August 2012)

    EPA Science Inventory

    Baghouses are air pollution control devices used to control particulate emissions from stationary sources and are among the technologies evaluated by the APCT Center. Baghouses and their accompanying filter media have long been one of the leading particulate control techniques fo...

  1. Electrically heated particulate filter enhanced ignition strategy

    DOEpatents

    Gonze, Eugene V; Paratore, Jr., Michael J

    2012-10-23

    An exhaust system that processes exhaust generated by an engine is provided. The system generally includes a particulate filter (PF) that filters particulates from the exhaust wherein an upstream end of the PF receives exhaust from the engine. A grid of electrically resistive material is applied to an exterior upstream surface of the PF and selectively heats exhaust passing through the grid to initiate combustion of particulates within the PF. A catalyst coating applied to at least one of the PF and the grid. A control module estimates a temperature of the grid and controls the engine to produce a desired exhaust product to increase the temperature of the grid.

  2. 40 CFR 52.725 - Control strategy: Particulates.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status... Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance... the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM...

  3. 40 CFR 52.725 - Control strategy: Particulates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status... Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance... the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM...

  4. 40 CFR 52.725 - Control strategy: Particulates.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status... Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance... the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM...

  5. 40 CFR 52.725 - Control strategy: Particulates.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status... Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance... the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM...

  6. CHARACTERIZATION OF PARTICULATE MATTER FROM PHOENIX, ARIZONA, USING RAY FLUORESCENCE AND COMPUTER-CONTROLLED SCANNING ELECTRON MICROSCOPY

    EPA Science Inventory

    Numerous epidemiological studies have found associations between airborne particulate matter measured at community monitors and increased mortality and morbidity. Chemical and physical characteristics of particulate matter (e.g., elemental composition, size) and source identifi...

  7. Hyperspectral imaging applied to complex particulate solids systems

    NASA Astrophysics Data System (ADS)

    Bonifazi, Giuseppe; Serranti, Silvia

    2008-04-01

    HyperSpectral Imaging (HSI) is based on the utilization of an integrated hardware and software (HW&SW) platform embedding conventional imaging and spectroscopy to attain both spatial and spectral information from an object. Although HSI was originally developed for remote sensing, it has recently emerged as a powerful process analytical tool, for non-destructive analysis, in many research and industrial sectors. The possibility to apply on-line HSI based techniques in order to identify and quantify specific particulate solid systems characteristics is presented and critically evaluated. The originally developed HSI based logics can be profitably applied in order to develop fast, reliable and lowcost strategies for: i) quality control of particulate products that must comply with specific chemical, physical and biological constraints, ii) performance evaluation of manufacturing strategies related to processing chains and/or realtime tuning of operative variables and iii) classification-sorting actions addressed to recognize and separate different particulate solid products. Case studies, related to recent advances in the application of HSI to different industrial sectors, as agriculture, food, pharmaceuticals, solid waste handling and recycling, etc. and addressed to specific goals as contaminant detection, defect identification, constituent analysis and quality evaluation are described, according to authors' originally developed application.

  8. Field testing of particulate matter continuous emission monitors at the DOE Oak Ridge TSCA incinerator. Toxic Substances Control Act.

    PubMed

    Dunn, James E; Davis, Wayne T; Calcagno, James A; Allen, Marshall W

    2002-01-01

    A field study to evaluate the performance of three commercially available particulate matter (PM) continuous emission monitors (CEMs) was conducted in 1999-2000 at the US Department of Energy (DOE) Toxic Substances Control Act (TSCA) Incinerator. This study offers unique features that are believed to enhance the collective US experience with PM CEMs. The TSCA Incinerator is permitted to treat PCB-contaminated RCRA hazardous low-level radioactive wastes. The air pollution control system utilizes MACT control technology and is comprised of a rapid quench, venturi scrubber, packed bed scrubber, and two ionizing wet scrubbers in series, which create a saturated flue gas that must be conditioned by the CEMs prior to measurement. The incinerator routinely treats a wide variety of wastes including high and low BTU organic liquids, aqueous, and solid wastes. The various possible combinations for treating liquid and solid wastes may present a challenge in establishing a single, acceptable correlation relationship for individual CEMs. The effect of low-level radioactive material present in the waste is a unique site-specific factor not evaluated in previous tests. The three systems chosen for evaluation were two beta gauge devices and a light scattering device. The performance of the CEMs was evaluated using the requirements in draft Environmental Protection Agency (EPA) Performance Specification 11 (PS11) and Procedure 2. The results of Reference Method 5i stack tests for establishing statistical correlations between the reference method data and the CEMs responses are discussed.

  9. Simulated Fuel Economy and Emissions Performance during City and Interstate Driving for a Heavy-Duty Hybrid Truck

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daw, C. Stuart; Gao, Zhiming; Smith, David E.

    2013-04-08

    We compare simulated fuel economy and emissions for both conventional and hybrid class 8 heavy-duty diesel trucks operating over multiple urban and highway driving cycles. Both light and heavy freight loads were considered, and all simulations included full aftertreatment for NOx and particulate emissions controls. The aftertreatment components included a diesel oxidation catalyst (DOC), urea-selective catalytic NOx reduction (SCR), and a catalyzed diesel particulate filter (DPF). Our simulated hybrid powertrain was configured with a pre-transmission parallel drive, with a single electric motor between the clutch and gearbox. A conventional HD truck with equivalent diesel engine and aftertreatment was also simulatedmore » for comparison. Our results indicate that hybridization can significantly increase HD fuel economy and improve emissions control in city driving. However, there is less potential hybridization benefit for HD highway driving. A major factor behind the reduced hybridization benefit for highway driving is that there are fewer opportunities to utilize regenerative breaking. Our aftertreatment simulations indicate that opportunities for passive DPF regeneration are much greater for both hybrid and conventional trucks during highway driving due to higher sustained exhaust temperatures. When passive DPF regeneration is extensively utilized, the fuel penalty for particulate control is virtually eliminated, except for the 0.4%-0.9% fuel penalty associated with the slightly higher exhaust backpressure.« less

  10. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  11. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  12. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  13. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  14. 40 CFR 60.2155 - May I conduct performance testing less often?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pollutant (particulate matter, hydrogen chloride, or opacity) over 3 consecutive years show that you comply... limitation for particulate matter, hydrogen chloride, or opacity, you may choose to conduct performance tests... matter, hydrogen chloride, or opacity, you must conduct annual performance tests for that pollutant until...

  15. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  16. Characterization of exhaust emissions from diesel-powered passenger cars with particular reference to unregulated components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lies, K.H.; Postulka, A.; Gring, H.

    Besides regulated components VW's research program in the field of characterization of diesel emissions comprises a detailed analysis of the particulates and a comprehensive study of a number of unregulated gaseous compounds. The following chemical compounds and classes of compounds are measured: particulates, traces of metals, major elements, sulfates, sulfur dioxide, hydrogen sulfide, hydrogen cyanide, aldehydes, ammonia, phenols, individual hydrocarbons, and odor (DOAS). The test fleet of this investigation included a number of VW and Audi cars equipped with 4-, and 5-cylinder diesel engines (naturally aspirated and turbocharged). All measurements were performed on a chassis dynamometer in accordance with themore » specification of the known US-test-procedures: Federal Test Procedure, Sulfate Emission Test, Fuel Economy Test. For sampling , in principle, the dilution tunnel technique was used combined with an automatically working collection system. This micro-processor controlled system involves 13 individual sample lines, 8 for gaseous and 5 for particulate components.« less

  17. Characterization of particulate matter binding peptides screened from phage display.

    PubMed

    Liang Alvin, Aw Wei; Tanaka, Masayoshi; Okochi, Mina

    2017-05-01

    Particulate matter (PM), especially particulates with diameters of less than 2.5 μm, can penetrate the alveolar region and increase the risk of respiratory diseases. This has stimulated research efforts to develop detection methods so that counter measures can be taken. In this study, four PM binding peptides were obtained by phage display and binding characteristics of these peptides were investigated using the peptide array. The strongest binding peptide, WQDFGAVRSTRS, displayed a binding property, measured in terms of spot intensity, 11.4 times higher than that of the negative control, AAAAA. Inductively coupled plasma mass spectrometry (ICPMS) analysis of the transition metal compounds in the PM bound to the peptide spots was performed, and two peptides showed higher binding towards Cu and Zn compounds in PM. These results suggest that the screened peptides could serve as an indicator of transition metal compounds, which are related to adverse health effects, contained in PM. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  18. EXPOSURE ASSESSMENT FROM THE NERL RESEARCH TRIANGLE PARK PARTICULATE MATTER PANEL STUDY

    EPA Science Inventory

    The U.S. Environmental Protection Agency performed a particulate matter (PM) exposure assessment based on data from the National Exposure Research Laboratory (NERL) Research Triangle Park (RTP) Particulate Matter (PM) Panel Study. This study was a one-year investigation of PM ...

  19. Inductively heated particulate matter filter regeneration control system

    DOEpatents

    Gonze, Eugene V; Paratore Jr., Michael J; Kirby, Kevin W; Phelps, Amanda; Gregoire, Daniel J

    2012-10-23

    A system includes a particulate matter (PM) filter with an upstream end for receiving exhaust gas, a downstream end and zones. The system also includes a heating element. A control module selectively activates the heating element to inductively heat one of the zones.

  20. FATE OF TRACE METALS IN A ROTARY KILN INCINERATOR WITH A SINGLE-STAGE IONIZING WET SCRUBBER. VOLUME 1. TECHNICAL RESULTS.

    EPA Science Inventory

    A series of pilot-scale incineration tests was performed at EPA's Incineration Research Facility (IRF) in Jefferson, Arkansas, to evaluate the fate of trace metals fed to a rotary kiln incinerator equipped with an ionizing wet scrubber (IWS) for particulate and acid gas control. ...

  1. Handbook on Air Cleaning Particulate Removal

    DTIC Science & Technology

    1952-09-01

    Type D Rotoclone, another type of (Fig. 2.7) has an exit duct fitted with an centrifugal dust separator (Fig. 2.8), in- adjustable collar which controls ...8091 10,870 15,056 18.620 Cost/sq ft cloth area 3.26 4.80 1.80 2.42 1.68 2.08 aIntermittent operation bAutomatic -continuous operation hh PERFORMANCE

  2. THE FATE OF TRACE METALS IN A ROTARY KILN INCINERATOR WITH A SINGLE-STAGE IONIZING WET SCRUBBER - VOLUME II: APPENDICES

    EPA Science Inventory

    A series of pilot-scale incineration tests was performed at EPA's Incineration Research Facility (IRF) in Jefferson, Arkansas, to evaluate the fate of trace metals fed to a rotary kiln incinerator equipped with an ionizing wet scrubber (IWS) for particulate and acid gas control. ...

  3. Fugitive dust emission source profiles and assessment of selected control strategies for particulate matter at gravel processing sites in Taiwan.

    PubMed

    Chang, Chang-Tang; Chang, Yu-Min; Lin, Wen-Yinn; Wu, Ming-Ching

    2010-10-01

    Particles emitted from gravel processing sites are one contributor to worsening air quality in Taiwan. Major pollution sources at gravel processing sites include gravel and sand piles, unpaved roads, material crushers, and bare ground. This study analyzed fugitive dust emission characteristics at each pollution source using several types of particle samplers, including total suspended particulates (TSP), suspended particulate (PM10), fine suspended particulate (PM2.5), particulate sizer, and dust-fall collectors. Furthermore, silt content and moisture in the gravel were measured to develop particulate emission factors. The results showed that TSP (< 100 microm) concentrations at the boundary of gravel sites ranged from 280 to 1290 microg/m3, which clearly exceeds the Taiwan hourly air quality standard of 500 microg/m3. Moreover, PM10 concentrations, ranging from 135 to 550 microg/m3, were also above the daily air quality standard of 125 microg/m3 and approximately 1.2 and 1.5 times the PM2.5 concentrations, ranging from 105 to 470 microg/m3. The size distribution analysis reveals that mass mean diameter and geometric standard deviation ranged from 3.2 to 5.7 microm and from 2.82 to 5.51, respectively. In this study, spraying surfactant was the most effective control strategy to abate windblown dust from unpaved roads, having a control efficiency of approximately 93%, which is significantly higher than using paved road strategies with a control efficiency of approximately 45%. For paved roads, wet suppression provided the best dust control efficiencies ranging from 50 to 83%. Re-vegetation of disturbed ground had dust control efficiencies ranging from 48 to 64%.

  4. THE RELATIONSHIP BETWEEN BOTH REAL-TIME AND TIME-INTEGRATED COARSE AND FINE PARTICULATE MATTER AT AN URBAN SITE IN LOS ANGELES

    EPA Science Inventory

    Population exposure to ambient particulate matter (PM) has received considerable attention due to the association between ambient particulate concentrations and mortality. Current toxicological studies and controlled human and animal exposures suggest that all size fractions of...

  5. Development and characterization of sugarcane bagasse fiber and nano-silica reinforced epoxy hybrid composites

    NASA Astrophysics Data System (ADS)

    Fong, A. L.; Khandoker, N. A. N.; Debnath, S.

    2018-04-01

    This paper presents an experimental study on the mechanical performance of sugarcane bagasse fiber reinforced epoxy composite. Tensile and flexural properties of the composites were investigated in this research. Different weightage of short fiber and fiber particulates were utilized to study their effects on the mechanical performance of the composites in terms of tensile and flexural properties. 1% of nano-silica was reinforced to investigate its effect on the mechanical performance of the composites. Hand lay-up composite molding process was used to fabricate the composite samples. During fabrication, ultrasonic mixing was carried out to study the effects on mechanical performance of the fiber particulate reinforced composites. In overall, ultrasonic mixing and addition of nano-silica particles has improved the mechanical performance of the fiber particulate composites. Morphology analysis on surface of composites has shown the removal of air bubbles and deagglomeration. 1wt% of short fiber reinforced composite exhibits the highest tensile and flexural properties among all the samples. Sugarcane bagasse particulates reinforced composites were shown to have better performance compared to short fiber reinforced composites when the wt% of the fiber increase.

  6. Environmental Technology Verification Report and Statement for Baghouse Filtration Products, W. L. Gore & Associates, Inc. 5117 High Durability PPS Laminate Filtration Media (Tested March-April 2012)

    EPA Science Inventory

    Baghouses are air pollution control devices used to control particulate emissions from stationary sources and are among the technologies evaluated by the APCT Center. Baghouses and their accompanying filter media have long been one of the leading particulate control techniques fo...

  7. 40 CFR 52.1678 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy and regulations: Particulate matter. 52.1678 Section 52.1678 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York...

  8. MULTISCALE AIR QUALITY SIMULATION PLATFORM (MAQSIP): INITIAL APPLICATIONS AND PERFORMANCE FOR TROPOSPHERIC OZONE AND PARTICULATE MATTER

    EPA Science Inventory

    This manuscript provides an overview of the formulation, process considerations, and performance for simulating tropospheric ozone and particulate matter distributions of the Multiscale Air Quality Simulation Platform (MAQSIP). MAQSIP is a comprehensive atmospheric chemistry/tran...

  9. Motorcycle pollution control in Taiwan, Republic of China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, H.W.; Hsiao, H.C.; Walsh, M.P.

    1998-12-31

    The Taiwan EPA has developed a comprehensive approach to motor vehicle pollution control. Building on its early adoption of US `83 standards for light duty vehicles (starting July 1, 1990) it recently moved to US `87 requirements, which include the 0.2 gram per mile particulate standard, as of July 1, 1995. Heavy duty diesel particulate standards almost as stringent as US `90, 6.0 grams per brake horsepower hour NO{sub x} and 0.7 particulate, using the US transient test procedure, went into effect on July 1, 1993. It is intended that US`94 standards, 5.0 NO{sub x} and 0.25 particulate, will bemore » adopted soon. Clearly the most distinctive feature of the Taiwan program, however, is its motorcycle control effort, reflecting the fact that motorcycles dominate the vehicle fleet and are a substantial source of emissions. This paper will summarize Taiwan`s extensive efforts to address this problem.« less

  10. JV Task 124 - Understanding Multi-Interactions of SO3, Mercury, Selenium, and Arsenic in Illinois Coal Flue Gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ye Zhuang; Christopher Martin; John Pavlish

    2009-03-31

    This project consisted of pilot-scale combustion testing with a representative Illinois basin coal to explore the multi-interactions of SO{sub 3}, mercury, selenium and arsenic. The parameters investigated for SO{sub 3} and mercury interactions included different flue gas conditions, i.e., temperature, moisture content, and particulate alkali content, both with and without activated carbon injection for mercury control. Measurements were also made to track the transformation of selenium and arsenic partitioning as a function of flue gas temperature through the system. The results from the mercury-SO{sub 3} testing support the concept that SO{sub 3} vapor is the predominant factor that impedes efficientmore » mercury removal with activated carbon in an Illinois coal flue gas, while H{sub 2}SO{sub 4} aerosol has less impact on activated carbon injection performance. Injection of a suitably mobile and reactive additives such as sodium- or calcium-based sorbents was the most effective strategy tested to mitigate the effect of SO{sub 3}. Transformation measurements indicate a significant fraction of selenium was associated with the vapor phase at the electrostatic precipitator inlet temperature. Arsenic was primarily particulate-bound and should be captured effectively with existing particulate control technology.« less

  11. DEVELOPMENT OF A SAMPLER FOR PARTICULATE-ASSOCIATED AND LOW VOLATILITY ORGANIC POLLUTANTS IN RESIDENTIAL AIR

    EPA Science Inventory

    The report describes the development of a sampler for particulate-associated and low volatility organic pollutants in residential air. The performance of the sampler inlet, which is compatible with the proposed PM-10 regulations for particulate sampling, is documented under a var...

  12. Atomizing apparatus for making polymer and metal powders and whiskers

    DOEpatents

    Otaigbe, Joshua U.; McAvoy, Jon M.; Anderson, Iver E.; Ting, Jason; Mi, Jia; Terpstra, Robert

    2003-03-18

    Method for making polymer particulates, such as spherical powder and whiskers, by melting a polymer material under conditions to avoid thermal degradation of the polymer material, atomizing the melt using gas jet means in a manner to form atomized droplets, and cooling the droplets to form polymer particulates, which are collected for further processing. Atomization parameters can be controlled to produce polymer particulates with controlled particle shape, particle size, and particle size distribution. For example, atomization parameters can be controlled to produce spherical polymer powders, polymer whiskers, and combinations of spherical powders and whiskers. Atomizing apparatus also is provided for atoomizing polymer and metallic materials.

  13. The impact of size on particulate vaccine adjuvants.

    PubMed

    Shah, Ruchi R; O'Hagan, Derek T; Amiji, Mansoor M; Brito, Luis A

    2014-12-01

    Particulate adjuvants have been successful at inducing increased immune responses against many poorly immunogenic antigens. However, the mechanism of action of these adjuvants often remains unclear. As more potential vaccine targets are emerging, it is becoming necessary to broaden our knowledge on the factors involved in generating potent immune responses to recombinant antigens with adjuvants. While composition of adjuvants is integral in defining the overall performance of an adjuvant, some physical parameters such as particle size, surface charge and surface modification may also contribute to the potency. In this review, we will try to highlight the role of particle size in controlling the immune responses to adjuvanted vaccines, with a focus on insoluble aluminum salts, oil-in-water emulsions, polymeric particles and liposomes.

  14. Integrin-directed modulation of macrophage responses to biomaterials.

    PubMed

    Zaveri, Toral D; Lewis, Jamal S; Dolgova, Natalia V; Clare-Salzler, Michael J; Keselowsky, Benjamin G

    2014-04-01

    Macrophages are the primary mediator of chronic inflammatory responses to implanted biomaterials, in cases when the material is either in particulate or bulk form. Chronic inflammation limits the performance and functional life of numerous implanted medical devices, and modulating macrophage interactions with biomaterials to mitigate this response would be beneficial. The integrin family of cell surface receptors mediates cell adhesion through binding to adhesive proteins nonspecifically adsorbed onto biomaterial surfaces. In this work, the roles of integrin Mac-1 (αMβ2) and RGD-binding integrins were investigated using model systems for both particulate and bulk biomaterials. Specifically, the macrophage functions of phagocytosis and inflammatory cytokine secretion in response to a model particulate material, polystyrene microparticles were investigated. Opsonizing proteins modulated microparticle uptake, and integrin Mac-1 and RGD-binding integrins were found to control microparticle uptake in an opsonin-dependent manner. The presence of adsorbed endotoxin did not affect microparticle uptake levels, but was required for the production of inflammatory cytokines in response to microparticles. Furthermore, it was demonstrated that integrin Mac-1 and RGD-binding integrins influence the in vivo foreign body response to a bulk biomaterial, subcutaneously implanted polyethylene terephthalate. A thinner foreign body capsule was formed when integrin Mac-1 was absent (~30% thinner) or when RGD-binding integrins were blocked by controlled release of a blocking peptide (~45% thinner). These findings indicate integrin Mac-1 and RGD-binding integrins are involved and may serve as therapeutic targets to mitigate macrophage inflammatory responses to both particulate and bulk biomaterials. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Indirect latex glove contamination and its inhibitory effect on vinyl polysiloxane polymerization.

    PubMed

    Kimoto, Katsuhiko; Tanaka, Kinya; Toyoda, Minoru; Ochiai, Kent T

    2005-05-01

    The inhibitory effect of indirect latex contamination on the polymerization of vinyl polysiloxane (VPS) impression material has been previously reported. However, the transfer of specific elements that cause inhibition has not been confirmed, nor has the removal of such contaminants been reported. This study examined the surfaces of materials commonly used in restorative procedures that were contaminated by indirect latex glove contact and then evaluated for inhibition of polymerization of VPS. The effect of selected cleansing procedures was then studied. Four experimental groups (n = 8) were prepared: (1) clean vinyl gloves (control), (2) clean gingival retraction cords (control), (3) contaminated vinyl gloves, and (4) contaminated gingival retraction cord. Microscopic evaluation of the appearance and the characterization of surface particulate contamination were performed for each. Three cleansing protocols were then evaluated for efficacy in cleaning vinyl glove surfaces contaminated by latex contact (n = 10): (1) brushing with water, (2) brushing with soap/rinsing with water, (3) cleansing with rubbing alcohol. The subsequent degree of VPS polymerization inhibition was evaluated subjectively. A chi-square test was used for data analysis (alpha=.05). Particulate sulfur elements and sulfur-chloride compounds were present on the contaminated substrates. None of the 3 cleansing procedures eliminated polymerization inhibition (P =.33). Residual elemental sulfur remained on all tested surfaces. Particulate sulfur and sulfur-chloride compounds were identified as the particulate contamination that resulted in polymerization inhibition of the tested VPS dental impression material. Removal of these contaminants from the tested vinyl gloves and gingival retraction cord was not possible with the 3 cleansing protocols tested in this study.

  16. Particulate Air Pollution Control for Army Coal-Fired Boiler Plants.

    DTIC Science & Technology

    1983-03-01

    Army flue gas . The condensed material usually is sticky and emissions control . Of the current new technologies. traps the flyash on the bag, where it... control device is made a matter of convenience. The location Flue gas temperature control is an important factor of other components is given the prime...consideration. *in the application of baghouses to flue gas particulate This often results in the particle-laden gas being forced control . Bag

  17. DAILY VARIATION OF PARTICULATE AIR POLLUTION AND POOR CARDIAC AUTONOMIC CONTROL IN THE ELDERLY

    EPA Science Inventory

    Particulate matter air pollution (PM) has been related to cardiovascular disease mortality in a number of recent studies. The pathophysiologic mechanisms for this association are under study. Low heart rate variability, a marker of poor cardiac autonomic control, is associated wi...

  18. 40 CFR 52.228 - Regulations: Particulate matter, Southeast Desert Intrastate Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California... particulate matter in the Southeast Desert Intrastate Region. (1) Imperial County Air Pollution Control District: (i) Rule 114A. (ii) Rule 116B. (2) Los Angeles County Air Pollution Control District: (i...

  19. 40 CFR 52.228 - Regulations: Particulate matter, Southeast Desert Intrastate Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California... particulate matter in the Southeast Desert Intrastate Region. (1) Imperial County Air Pollution Control District: (i) Rule 114A. (ii) Rule 116B. (2) Los Angeles County Air Pollution Control District: (i...

  20. 40 CFR 52.228 - Regulations: Particulate matter, Southeast Desert Intrastate Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California... particulate matter in the Southeast Desert Intrastate Region. (1) Imperial County Air Pollution Control District: (i) Rule 114A. (ii) Rule 116B. (2) Los Angeles County Air Pollution Control District: (i...

  1. Importance of filter’s microstructure in dynamic filtration modeling of gasoline particulate filters (GPFs): Inhomogeneous porosity and pore size distribution

    DOE PAGES

    Gong, Jian; Stewart, Mark L.; Zelenyuk, Alla; ...

    2018-01-03

    The state-of-the-art multiscale modeling of gasoline particulate filter (GPF) including channel scale, wall scale, and pore scale is described. The microstructures of two GPFs were experimentally characterized. The pore size distributions of the GPFs were determined by mercury porosimetry. The porosity was measured by X-ray computed tomography (CT) and found to be inhomogeneous across the substrate wall. The significance of pore size distribution with respect to filtration performance was analyzed. The predictions of filtration efficiency were improved by including the pore size distribution in the filtration model. A dynamic heterogeneous multiscale filtration (HMF) model was utilized to simulate particulate filtrationmore » on a single channel particulate filter with realistic particulate emissions from a spark-ignition direct-injection (SIDI) gasoline engine. The dynamic evolution of filter’s microstructure and macroscopic filtration characteristics including mass- and number-based filtration efficiencies and pressure drop were predicted and discussed. In conclusion, the microstructure of the GPF substrate including inhomogeneous porosity and pore size distribution is found to significantly influence local particulate deposition inside the substrate and macroscopic filtration performance and is recommended to be resolved in the filtration model to simulate and evaluate the filtration performance of GPFs.« less

  2. Importance of filter’s microstructure in dynamic filtration modeling of gasoline particulate filters (GPFs): Inhomogeneous porosity and pore size distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Jian; Stewart, Mark L.; Zelenyuk, Alla

    The state-of-the-art multiscale modeling of gasoline particulate filter (GPF) including channel scale, wall scale, and pore scale is described. The microstructures of two GPFs were experimentally characterized. The pore size distributions of the GPFs were determined by mercury porosimetry. The porosity was measured by X-ray computed tomography (CT) and found to be inhomogeneous across the substrate wall. The significance of pore size distribution with respect to filtration performance was analyzed. The predictions of filtration efficiency were improved by including the pore size distribution in the filtration model. A dynamic heterogeneous multiscale filtration (HMF) model was utilized to simulate particulate filtrationmore » on a single channel particulate filter with realistic particulate emissions from a spark-ignition direct-injection (SIDI) gasoline engine. The dynamic evolution of filter’s microstructure and macroscopic filtration characteristics including mass- and number-based filtration efficiencies and pressure drop were predicted and discussed. In conclusion, the microstructure of the GPF substrate including inhomogeneous porosity and pore size distribution is found to significantly influence local particulate deposition inside the substrate and macroscopic filtration performance and is recommended to be resolved in the filtration model to simulate and evaluate the filtration performance of GPFs.« less

  3. Contamination control program for the Extreme Ultraviolet Explorer instruments

    NASA Technical Reports Server (NTRS)

    Ray, David C.; Malina, Roger F.; Welsh, Barry Y.; Austin, James D.; Teti, Bonnie Gray

    1989-01-01

    A contamination-control program has been instituted for the optical components of the EUV Explorer satellite, whose 80-900 A range performance is easily degraded by particulate and molecular contamination. Cleanliness requirements have been formulated for the design, fabrication, and test phases of these instruments; in addition, contamination-control steps have been taken which prominently include the isolation of sensitive components in a sealed optics cavity. Prelaunch monitoring systems encompass the use of quartz crystal microbalances, particle witness plates, direct flight hardware sampling, and optical witness sampling of EUV scattering and reflectivity.

  4. Mobile Gas and Particulate Emission Studies of the New York City Transit Bus Fleet

    NASA Astrophysics Data System (ADS)

    Jayne, J. T.; Canagaratna, M.; Herndon, S.; Shorter, J.; Zahniser, M.; Shi, Q.; Kolb, C.; Worsnop, D.; Jimenez, J.; Drewnick, F.; Demerjian, K.; Lanni, T.

    2001-12-01

    Emissions from both diesel and gasoline powered motor vehicles are a significant source of particulate (PM2.5) and trace gas pollution, especially in urban environments. Emission characterizations of motor vehicles can be performed using a dynamometer but these studies make fleet characterization impractical. Few studies have been performed which characterize emissions from in-use vehicles using a mobile sampling platform. This work describes application of new technology instrumentation for rapid (1-5 second) and real-time characterization of both gas and particulate emissions from in-use vehicles and is part of the PM2.5 Technology Assessment and Characterization Study in New York (PMTACS-NY). An aerosol mass spectrometer (AMS) and a tunable infrared laser differential absorption spectrometer (TILDAS) system were deployed on the Aerodyne Research mobile laboratory designed to "chase" target vehicles in and around the New York City area and measure their emissions under actual driving conditions. The AMS provides particle size and composition information for volatile and semi-volatile matter while the TILDAS system was configured to measure NO, NO2, CO, CH4, SO2 and formaldehyde. In addition to a GPS, an ELPI and a condensation particle counter, the mobile laboratory was also equipped with a CO2 monitor to allow emission ratios to be computed for the targeted vehicles. Emission ratios for both particulate and trace gases are reported for a representative fraction of the NYC Metropolitan Transit Authority (MTA) bus fleet in an effort to characterize new emission control technologies currently implemented by the NYC MTA.

  5. Electrically heated DPF start-up strategy

    DOEpatents

    Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

    2012-04-10

    An exhaust system that processes exhaust generated by an engine has a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates in the exhaust. An electrical heater is disposed upstream of the DPF and selectively heats the exhaust to initiate combustion of the particulates. Heat generated by combustion of particulates in the heater induces combustion of particulates within the DPF. A control module selectively enables current flow to the electrical heater for an initial period of a DPF regeneration cycle, and limits exhaust flow while the electrical heater is heating to a predetermined soot combustion temperature.

  6. EVALUATION OF THE COMMUNITY MULTISCALE AIR QUALITY (CMAQ) MODEL VERSION 4.5: UNCERTAINTIES AND SENSITIVITIES IMPACTING MODEL PERFORMANCE: PART II - PARTICULATE MATTER

    EPA Science Inventory

    This paper presents an analysis of the CMAQ v4.5 model performance for particulate matter and its chemical components for the simulated year 2001. This is part two is two part series of papers that examines the model performance of CMAQ v4.5.

  7. USERS GUIDE FOR THE CONVERSION OF NAVY PAINT SPRAY BOOTH PARTICULATE EMISSION CONTROL SYSTEMS FROM WET TO DRY OPERATION

    EPA Science Inventory

    The report is a guide or convrting U.S. Navy paint spray booth particulate emission control systems from wet to dry operation. The use of water curtains for air pollution control of paint spray booths is considered a major source of water and solid waste pol-lution from industria...

  8. Mobile Particulate Emission Studies of New York City Vehicles

    NASA Astrophysics Data System (ADS)

    Canagaratna, M.; Jayne, J.; Shi, Q.; Kolb, C. E.; Worsnop, D.

    Emissions from both diesel and gasoline powered motor vehicles are a significant source of urban particulate (PM2.5) and trace gas pollution. Emission characteriza- tions of motor vehicles are typically performed using a dynamometer. Few studies have been performed which characterize emissions from in-use vehicles using a mo- bile sampling platform. This work, which was part of the PM2.5 Technology Assess- ment and Characterization Study in New York (PMTACS-NY), describes the applica- tion of new instrumentation for rapid (1-5 second) and real-time characterization of particulate emissions from in-use vehicles . An Aerosol Mass Spectrometer (AMS) was deployed on the Aerodyne Research (ARI) mobile laboratory designed to "chase" target vehicles in and around the New York City area and measure their emissions under actual driving conditions. The AMS provides quantitative particle size and composition information for volatile and semi- volatile matter (0.05-2.5 um). The AMS was operated in a fast acquisition mode de- signed to monitor particle emissions from the mobile sources. In this mode mass spec- tra (0-300 amu) and chemically speciated particle size distributions were recorded at 4 sec intervals. In addition to the AMS, the Mobile Laboratory was equipped with the ARI tunable diode laser (TILDAS) system which was configured to measure NO, NO2, CO, CH4, SO2 and formaldehyde, a global positioning system, a condensation particle counter, and a Licor CO2 instrument. The simultaneous measurement of particulate mass loading and plume CO2 enabled the calculation of emission indices for the targeted vehicles. Particulate matter emis- sion indices for a representative fraction of the NYC Metropolitan Transit Authority (MTA) bus fleet were determined in an effort to characterize new emission control technologies currently implemented by the NYC MTA. In addition to total particle emission indices, chemically speciated sulfate and organic mass loadings and size distributions were determined. Representative mass spectral signatures and size dis- tributions observed from the exhaust plume particles and correlations between the simultaneous gas and particulate measurements will be discussed. Differences in ob- served particle emission factors and compositions between buses using different fuels and technologies will also be presented.

  9. Inhalation of diesel engine exhaust affects spermatogenesis in growing male rats.

    PubMed

    Watanabe, N; Oonuki, Y

    1999-07-01

    We conducted experiments to determine whether diesel engine exhaust affects reproductive endocrine function in growing rats. The rats were assigned to three groups: a group exposed to total diesel engine exhaust containing 5.63 mg/m3 particulate matter, 4.10 ppm nitrogen dioxide, and 8.10 ppm nitrogen oxide; a group exposed to filtered exhaust without particulate matter; and a group exposed to clean air. Dosing experiments were performed for 3 months beginning at birth (6 hr/day for 5 days/week). Serum levels of testosterone and estradiol were significantly higher in animals exposed to total diesel exhaust and filtered exhaust (p < 0.05 for each group) as compared to the controls. Follicle-stimulating hormone was significantly decreased in the two groups exposed to diesel exhaust as compared to the control group (p < 0.05). Luteinizing hormone was significantly decreased in the total exhaust-exposed group as compared to the control and filtered groups (p < 0.05). Although testis weight did not show any significant difference among the groups, sperm production and activity of testicular hyaluronidase were significantly reduced in both exhaust-exposed groups as compared to the control group. Histological examination showed decreased numbers of step 18 and 19 spermatids in stage VI, VII, and VIII tubules in the testes of both diesel exhaust-exposed groups. This study suggests that diesel exhaust stimulates hormonal secretion of the adrenal cortex, depresses gonadotropin-releasing-hormone, and inhibits spermatogenesis in rats. Because these effects were not inhibited by filtration, the gaseous phase of the exhaust appears to be more responsible than particulate matter for disrupting the endocrine system.

  10. 40 CFR 52.1230 - Control strategy and rules: Particulates.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Minnesota § 52.1230 Control strategy and rules: Particulates. (a) Part D(1) Approval. The State of Minnesota has satisfied the... provision of Rule 7005.2910. (b) Approval—On May 31, 1988, the State of Minnesota submitted a committal SIP...

  11. 40 CFR 52.1230 - Control strategy and rules: Particulates.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Minnesota § 52.1230 Control strategy and rules: Particulates. (a) Part D—(1) Approval. The State of Minnesota has satisfied... alternative test method provision of Rule 7005.2910. (b) Approval—On May 31, 1988, the State of Minnesota...

  12. 40 CFR 52.1230 - Control strategy and rules: Particulates.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Minnesota § 52.1230 Control strategy and rules: Particulates. (a) Part D—(1) Approval. The State of Minnesota has satisfied... alternative test method provision of Rule 7005.2910. (b) Approval—On May 31, 1988, the State of Minnesota...

  13. 40 CFR 52.1230 - Control strategy and rules: Particulates.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Minnesota § 52.1230 Control strategy and rules: Particulates. (a) Part D—(1) Approval. The State of Minnesota has satisfied... alternative test method provision of Rule 7005.2910. (b) Approval—On May 31, 1988, the State of Minnesota...

  14. 40 CFR 52.1230 - Control strategy and rules: Particulates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Minnesota § 52.1230 Control strategy and rules: Particulates. (a) Part D—(1) Approval. The State of Minnesota has satisfied... alternative test method provision of Rule 7005.2910. (b) Approval—On May 31, 1988, the State of Minnesota...

  15. PROCEEDINGS: SEMINAR ON IN-STACK PARTICLE SIZING FOR PARTICULATE CONTROL DEVICE EVALUATION

    EPA Science Inventory

    The proceedings document discussions during an EPA/IERL-RTP-sponsored seminar on In-stack Particle Sizing for Particulate Control Device Evaluation. The seminar, organized by IERL-RTP's Process Measurements Branch, was held at IERL-RTP in North Carolina on December 3 and 4, 1975....

  16. EPA AND ERDA HIGH-TEMPERATURE/HIGH-PRESSURE PARTICULATE CONTROL PROGRAMS

    EPA Science Inventory

    The report describes and compares current projects sponsored by EPA and the U.S. Energy Research and Development Administration (ERDA), relating to the control of particulate matter in fuel gas streams at high temperatures (1000 to 2000F) and high pressures (5 atm and greater). T...

  17. Use of high-volume outdoor smog chamber photo-reactors for studying physical and chemical atmospheric aerosol formation and composition

    NASA Astrophysics Data System (ADS)

    Borrás, E.; Ródenas, M.; Vera, T.; Muñoz, A.

    2015-12-01

    The atmospheric particulate matter has a large impact on climate, biosphere behaviour and human health. Its study is complex because of large number of species are present at low concentrations and the continuous time evolution, being not easily separable from meteorology, and transport processes. Closed systems have been proposed by isolating specific reactions, pollutants or products and controlling the oxidizing environment. High volume simulation chambers, such as EUropean PHOtoREactor (EUPHORE), are an essential tool used to simulate atmospheric photochemical reactions. This communication describes the last results about the reactivity of prominent atmospheric pollutants and the subsequent particulate matter formation. Specific experiments focused on organic aerosols have been developed at the EUPHORE photo-reactor. The use of on-line instrumentation, supported by off-line techniques, has provided well-defined reaction profiles, physical properties, and up to 300 different species are determined in particulate matter. The application fields include the degradation of anthropogenic and biogenic pollutants, and pesticides under several atmospheric conditions, studying their contribution on the formation of secondary organic aerosols (SOA). The studies performed at the EUPHORE have improved the mechanistic studies of atmospheric degradation processes and the knowledge about the chemical and physical properties of atmospheric particulate matter formed during these processes.

  18. Level 1 environmental assessment performance evaluation. Final report jun 77-oct 78

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Estes, E.D.; Smith, F.; Wagoner, D.E.

    1979-02-01

    The report gives results of a two-phased evaluation of Level 1 environmental assessment procedures. Results from Phase I, a field evaluation of the Source Assessment Sampling System (SASS), showed that the SASS train performed well within the desired factor of 3 Level 1 accuracy limit. Three sample runs were made with two SASS trains sampling simultaneously and from approximately the same sampling point in a horizontal duct. A Method-5 train was used to estimate the 'true' particulate loading. The sampling systems were upstream of the control devices to ensure collection of sufficient material for comparison of total particulate, particle sizemore » distribution, organic classes, and trace elements. Phase II consisted of providing each of three organizations with three types of control samples to challenge the spectrum of Level 1 analytical procedures: an artificial sample in methylene chloride, an artificial sample on a flyash matrix, and a real sample composed of the combined XAD-2 resin extracts from all Phase I runs. Phase II results showed that when the Level 1 analytical procedures are carefully applied, data of acceptable accuracy is obtained. Estimates of intralaboratory and interlaboratory precision are made.« less

  19. 40 CFR 60.42Da - Standard for particulate matter (PM).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter (PM). 60.42Da Section 60.42Da Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR....42Da Standard for particulate matter (PM). (a) On and after the date on which the initial performance...

  20. 40 CFR 60.42Da - Standard for particulate matter (PM).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter (PM). 60.42Da Section 60.42Da Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR....42Da Standard for particulate matter (PM). (a) On and after the date on which the initial performance...

  1. Particulate generation and control in the PREPP (Process Experimental Pilot Plant) incinerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stermer, D.L.; Gale, L.G.

    1989-03-01

    Particulate emissions in radioactive incineration systems using a wet scrubbing system are generally ultimately controlled by flowing the process offgas stream through a high-efficiency filter, such as a High Efficient Particulate Air (HEPA) filter. Because HEPA filters are capable of reducing particulate emissions over an order of magnitude below regulatory limits, they consequently are vulnerable to high loading rates. This becomes a serious handicap in radioactive systems when filter change-out is required at an unacceptably high rate. The Process Experimental Pilot Plant (PREPP) incineration system is designed for processing retrieved low level mixed hazardous waste. It has a wet offgasmore » treatment system consisting of a Quencher, Venturi Scrubber, Entrainment Eliminator, Mist Eliminator, two stages of HEPA filters, and induced draft fans. During previous tests, it was noted that the offgas filters loaded with particulate at a rate requiring replacement as often as every four hours. During 1988, PREPP conducted a series of tests which included an investigation of the causes of heavy particulate accumulation on the offgas filters in relation to various operating parameters. This was done by measuring the particulate concentrations in the offgas system, primarily as a function of scrub solution salt concentration, waste feed rate, and offgas flow rate. 2 figs., 9 tabs.« less

  2. THE RELATIONSHIP BETWEEN REAL-TIME AND TIME-INTEGRATED COARSE (2.5-10MM), INTERMEDIATE (1-2.5MM), AND FINE (<2.5MM) PARTICULATE MATTER IN THE LOS ANGELES BASIN

    EPA Science Inventory

    Population exposure to ambient particulate matter (PM) has received considerable attention due to the association between ambient particulate concentrations and mortality. Current toxicological and epidemiological studies and controlled human and animal exposures suggest that a...

  3. Baumot BA-B Diesel Particulate Filter with Pre-Catalyst (ETV Mobile Source Emissions Control Devices) Verification Report

    EPA Science Inventory

    The Baumot BA-B Diesel Particulate Filter with Pre-Catalyst is a diesel engine retrofit device for light, medium, and heavy heavy-duty diesel on-highway engines for use with commercial ultra-low-sulfur diesel (ULSD) fuel. The BA-B particulate filter is composed of a pre-catalyst ...

  4. Advanced particulate matter control apparatus and methods

    DOEpatents

    Miller, Stanley J [Grand Forks, ND; Zhuang, Ye [Grand Forks, ND; Almlie, Jay C [East Grand Forks, MN

    2012-01-10

    Apparatus and methods for collection and removal of particulate matter, including fine particulate matter, from a gas stream, comprising a unique combination of high collection efficiency and ultralow pressure drop across the filter. The apparatus and method utilize simultaneous electrostatic precipitation and membrane filtration of a particular pore size, wherein electrostatic collection and filtration occur on the same surface.

  5. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD USE OF THE PARTICULATE SAMPLER (UA-F-3.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the in-field use of the particulate sampling system (pumping, control unit, and size selective inlet impactors) for collecting samples of particulate matter from the air during a predetermined time period during the Arizona NHEXAS project an...

  6. Sensitivity analyses of factors influencing CMAQ performance for fine particulate nitrate.

    PubMed

    Shimadera, Hikari; Hayami, Hiroshi; Chatani, Satoru; Morino, Yu; Mori, Yasuaki; Morikawa, Tazuko; Yamaji, Kazuyo; Ohara, Toshimasa

    2014-04-01

    Improvement of air quality models is required so that they can be utilized to design effective control strategies for fine particulate matter (PM2.5). The Community Multiscale Air Quality modeling system was applied to the Greater Tokyo Area of Japan in winter 2010 and summer 2011. The model results were compared with observed concentrations of PM2.5 sulfate (SO4(2-)), nitrate (NO3(-)) and ammonium, and gaseous nitric acid (HNO3) and ammonia (NH3). The model approximately reproduced PM2.5 SO4(2-) concentration, but clearly overestimated PM2.5 NO3(-) concentration, which was attributed to overestimation of production of ammonium nitrate (NH4NO3). This study conducted sensitivity analyses of factors associated with the model performance for PM2.5 NO3(-) concentration, including temperature and relative humidity, emission of nitrogen oxides, seasonal variation of NH3 emission, HNO3 and NH3 dry deposition velocities, and heterogeneous reaction probability of dinitrogen pentoxide. Change in NH3 emission directly affected NH3 concentration, and substantially affected NH4NO3 concentration. Higher dry deposition velocities of HNO3 and NH3 led to substantial reductions of concentrations of the gaseous species and NH4NO3. Because uncertainties in NH3 emission and dry deposition processes are probably large, these processes may be key factors for improvement of the model performance for PM2.5 NO3(-). The Community Multiscale Air Quality modeling system clearly overestimated the concentration of fine particulate nitrate in the Greater Tokyo Area of Japan, which was attributed to overestimation of production of ammonium nitrate. Sensitivity analyses were conducted for factors associated with the model performance for nitrate. Ammonia emission and dry deposition of nitric acid and ammonia may be key factors for improvement of the model performance.

  7. 40 CFR 60.422 - Standards for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate... required to be conducted by § 60.8 is completed, no owner or operator of an ammonium sulfate dryer subject... of ammonium sulfate produced (0.30 pound of particulate per ton of ammonium sulfate produced) and...

  8. 40 CFR 60.402 - Standard for particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Phosphate Rock... subpart shall cause to be discharged into the atmosphere: (1) From any phosphate rock dryer any gases which: (i) Contain particulate matter in excess of 0.030 kilogram per megagram of phosphate rock feed (0...

  9. 40 CFR 60.402 - Standard for particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Phosphate Rock... subpart shall cause to be discharged into the atmosphere: (1) From any phosphate rock dryer any gases which: (i) Contain particulate matter in excess of 0.030 kilogram per megagram of phosphate rock feed (0...

  10. 40 CFR 60.402 - Standard for particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Phosphate Rock... subpart shall cause to be discharged into the atmosphere: (1) From any phosphate rock dryer any gases which: (i) Contain particulate matter in excess of 0.030 kilogram per megagram of phosphate rock feed (0...

  11. 40 CFR 60.402 - Standard for particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Phosphate Rock... subpart shall cause to be discharged into the atmosphere: (1) From any phosphate rock dryer any gases which: (i) Contain particulate matter in excess of 0.030 kilogram per megagram of phosphate rock feed (0...

  12. 40 CFR 60.402 - Standard for particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Phosphate Rock... subpart shall cause to be discharged into the atmosphere: (1) From any phosphate rock dryer any gases which: (i) Contain particulate matter in excess of 0.030 kilogram per megagram of phosphate rock feed (0...

  13. 42 CFR 84.1157 - Chemical cartridge respirators with particulate filters; performance requirements; general.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Chemical cartridge respirators with particulate filters; performance requirements; general. 84.1157 Section 84.1157 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  14. 42 CFR 84.1157 - Chemical cartridge respirators with particulate filters; performance requirements; general.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Chemical cartridge respirators with particulate filters; performance requirements; general. 84.1157 Section 84.1157 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  15. 42 CFR 84.1157 - Chemical cartridge respirators with particulate filters; performance requirements; general.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Chemical cartridge respirators with particulate filters; performance requirements; general. 84.1157 Section 84.1157 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  16. 42 CFR 84.1157 - Chemical cartridge respirators with particulate filters; performance requirements; general.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Chemical cartridge respirators with particulate filters; performance requirements; general. 84.1157 Section 84.1157 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  17. 42 CFR 84.1157 - Chemical cartridge respirators with particulate filters; performance requirements; general.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Chemical cartridge respirators with particulate filters; performance requirements; general. 84.1157 Section 84.1157 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  18. Improved Electronic Control for Electrostatic Precipitators

    NASA Technical Reports Server (NTRS)

    Johnston, D. F.

    1986-01-01

    Electrostatic precipitators remove particulate matter from smoke created by burning refuse. Smoke exposed to electrostatic field, and particles become electrically charged and migrate to electrically charged collecting surfaces. New microprocessor-based electronic control maintains precipitator power at maximum particulate-collection level. Control automatically senses changes in smoke composition due to variations in fuel or combustion and adjusts precipitator voltage and current accordingly. Also, sensitive yet stable fault detection provided.

  19. Laboratory evaluation of electrostatic spray wet scrubber to control particulate matter emissions from poultry facilities

    USDA-ARS?s Scientific Manuscript database

    Particulate matter (PM) is a major air pollutant emitted from animal production and has significant impacts on health and the environment. Abatement of PM emissions is imperative and effective PM control technologies are strongly needed. In this work, an electrostatic spray wet scrubber (ESWS) techn...

  20. 40 CFR 52.126 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Therefore, Regulation 7-1-3.6 (process industries) of the Arizona Rules and Regulations for Air Pollution... regulation for Regulation 7-1-3.6 of the Arizona Rules and Regulations for Air Pollution Control (Gila... regulation 7-3-1.7 (Particulate Emissions—Fuel Burning Equipment) of the Rules and Regulations for Pinal-Gila...

  1. 40 CFR 52.126 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Therefore, Regulation 7-1-3.6 (process industries) of the Arizona Rules and Regulations for Air Pollution... regulation for Regulation 7-1-3.6 of the Arizona Rules and Regulations for Air Pollution Control (Gila... regulation 7-3-1.7 (Particulate Emissions—Fuel Burning Equipment) of the Rules and Regulations for Pinal-Gila...

  2. 40 CFR 52.126 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Therefore, Regulation 7-1-3.6 (process industries) of the Arizona Rules and Regulations for Air Pollution... regulation for Regulation 7-1-3.6 of the Arizona Rules and Regulations for Air Pollution Control (Gila... regulation 7-3-1.7 (Particulate Emissions—Fuel Burning Equipment) of the Rules and Regulations for Pinal-Gila...

  3. Radio Frequency Sensing of Particulate Matter Accumulation on a Gasoline Particulate Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parks, James; Prikhodko, Vitaly Y.; Sappok, Alex

    Filter Sensing Technology’s radio frequency (RF) sensor for particulate filter on-board diagnostics (OBD) was studied on a lean gasoline engine at the National Transportation Research Center (NTRC) at Oak Ridge National Laboratory (ORNL). The response of the RF sensor to particulate matter (PM) or “soot” accumulation on the gasoline particulate filter (GPF) installed in the engine exhaust was evaluated. In addition, end plugs of the GPF were purposely removed, and subsequent changes to the RF sensor measured soot loading on the GPF were characterized. Results from the study showed that the RF sensor can accurately measure soot accumulation on amore » GPF; furthermore, the predicted decreased soot accumulation due to plug removal was detected by the RF sensor. Overall, the studies were short and preliminary in nature; however, clearly, the RF sensor demonstrated the capability of measuring GPF soot loading at a level suitable for use in lean gasoline engine emission control OBD and control.« less

  4. 40 CFR 63.9621 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... must I use to demonstrate initial compliance with the emission limits for particulate matter? 63.9621... the emission limits for particulate matter? (a) You must conduct each performance test that applies to... source, you must determine compliance with the applicable emission limit for particulate matter in Table...

  5. 40 CFR 63.9621 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... must I use to demonstrate initial compliance with the emission limits for particulate matter? 63.9621... the emission limits for particulate matter? (a) You must conduct each performance test that applies to... source, you must determine compliance with the applicable emission limit for particulate matter in Table...

  6. Influenza virus infection in mice after exposure to coal dust and diesel engine emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahon, N.; Booth, J.A.; Green, F.

    1985-06-01

    Influenza virus infection initiated after aerosol exposure of CD-1, white Swiss mice for durations of 1, 3, and 6 months to respirable particulates maintained at 2 mg/m3 of either coal dust (CD), diesel engine emissions (DEE), a combination of both (CD/DEE), or to filtered air (control) was studied. The course of infection in mice previously exposed for 1 month to various particulates did not differ appreciably among the four animal groups with respect to mortality, virus growth in lungs, interferon levels, or hemagglutinin antibody response. In mice exposed for 3 and 6 months to different particulates, the mortality response wasmore » similar among all animal groups. However, the percentage of animals showing lung consolidation was significantly higher in the 3-month groups exposed to DEE (96.5%) and CD/DEE (97%) than in the control (61.2%); in the 6-month groups, the percentages were twice that of the control for both DEE- and CD/DEE-exposed animals. Complementing these observations of both 3- and 6-month-exposed animals was the higher virus growth levels attained in the DEE and CD/DEE animals with concomitant depressed interferon levels which were the inverse of findings noted in the control group. Hemagglutinin-antibody levels in particulate-exposed animals, especially at the 6-month interval, were fourfold less than the control. Histopathologic examination of lungs revealed no qualitative differences in the inflammatory response at any one specified time interval of exposure to influenza virus among the control and particulate-exposed animal groups. However, there were differences in severity of reaction in relation to the particulate component of the exposures. Focal macular collections of pigment-laden macrophages were seen only in DEE and CD/DEE but not in CD animals after 3- and 6-month exposures.« less

  7. A study of the effectiveness of particulate cleaning protocols on intentionally contaminated niobium surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reece, Charles E.; Ciancio, Elizabeth J.; Keyes, Katharine A.

    2009-11-01

    Particulate contamination on the surface of SRF cavities limits their performance via the enhanced generation of field-emitted electrons. Considerable efforts are expended to actively clean and avoid such contamination on niobium surfaces. The protocols in active use have been developed via feedback from cavity testing. This approach has the risk of over-conservatively ratcheting an ever increasing complexity of methods tied to particular circumstances. A complementary and perhaps helpful approach is to quantitatively assess the effectiveness of candidate methods at removing intentional representative particulate contamination. Toward this end, we developed a standardized contamination protocol using water suspensions of Nb{sub 2}O{sub 5}more » and SS 316 powders applied to BCP’d surfaces of standardized niobium samples yielding particle densities of order 200 particles/mm{sup 2}. From these starting conditions, controlled application of high pressure water rinse, ultrasonic cleaning, or CO{sub 2} snow jet cleaning was applied and the resulting surfaces examined via SEM/scanning EDS with particle recognition software. Results of initial parametric variations of each will be reported.« less

  8. Contamination avoidance devices for poppettype shutoff valves

    NASA Technical Reports Server (NTRS)

    Endicott, D. L.

    1973-01-01

    The determination of the cycle life is reported of the scal closure of a typical poppet-type shutoff valve in an uncontaminated GH2 environment and then compared this component performance with simulated operation with GN2 and LN2 containing controlled amounts of AL2O3 contaminant particles. The original valve design was tested for contamination damage tolerance characteristics under full-flow and cyclic-operating conditions, redesigned to improve the damage tolerance to contaminants, and then retested. The redesigned valve was found to have acceptable tolerance characteristics under all full-flow conditions and cyclic operation with small (25-75 microns) particulate contamination. The tolerance characteristics of the valve under cyclic conditions with large (75-250 microns) particulate contamination was improved but was not found to be completely satisfactory.

  9. Fuel-Burning Technology Alternatives for the Army.

    DTIC Science & Technology

    1985-01-01

    control 0.85 2,287,000 Flue gas desulfurization 0.68 3,410,000 Total 12,478,000 *Capital cost estimate...34......... . . Particulate and sulfur dioxide control are needed. A baghouse and flue gas desulfurization (FD) scrubber system must be installed. Each item’s cost in...direct cost) Contingency (20% of 1,253,000 direct and indirect costs) Subtotal 7,518,000 Particulate control 1,342,000 Flue gas desulfurization

  10. Electrically heated particulate matter filter soot control system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonze, Eugene V.; Paratore, Jr., Michael J.; Bhatia, Garima

    A regeneration system includes a particulate matter (PM) filter with an upstream end for receiving exhaust gas and a downstream end. A control module determines a current soot loading level of the PM filter and compares the current soot loading level to a predetermined soot loading level. The control module permits regeneration of the PM filter when the current soot loading level is less than the predetermined soot loading level.

  11. DETERMINING COARSE PARTICULATE MATTER CONCENTRATIONS: A PERFORMANCE EVALUATION OF CANDIDATE METHODOLOGIES UNDER WINTERTIME CONDITIONS

    EPA Science Inventory

    The main objective of this study is to evaluate the performance of sampling methods for potential use as a Federal Reference Method (FRM) capable of providing an estimate of coarse particle (PMc: particulate matter with an aerodynamic diameter between 2.5 um and 10 um) mass con...

  12. Effectiveness of radiation synovectomy with samarium-153 particulate hydroxyapatite in rheumatoid arthritis patients with knee synovitis: a controlled randomized double-blind trial.

    PubMed

    Santos, Marla Francisca dos; Furtado, Rita Nely Vilar; Konai, Monique Sayuri; Castiglioni, Mario Luiz Vieira; Marchetti, Renata Rosa; Natour, Jamil

    2009-01-01

    The aim of the present study was to investigate the effectiveness of Samarium(153)-particulate hydroxyapatite radiation synovectomy in rheumatoid arthritis patients with chronic knee synovitis. Fifty-eight rheumatoid arthritis patients (60 knees) with chronic knee synovitis participated in a controlled double-blinded trial. Patients were randomized to receive either an intra-articular injection with 40 mg triamcinolone hexacetonide alone (TH group) or 40 mg triamcinolone hexacetonide combined with 15 mCi Samarium(153)-particulate hydroxyapatite (Sm/TH group). Blinded examination at baseline (T0) and at 1 (T1), 4 (T4), 12 (T12), 32 (T32), and 48 (T48) weeks post-intervention were performed on all patients and included a visual analog scale for joint pain and swelling as well as data on morning stiffness, flexion, extension, knee circumference, Likert scale of improvement, percentage of improvement, SF-36 generic quality of life questionnaire, Stanford Health Assessment Questionnaire (HAQ), Lequesne index, use of non-steroidal anti-inflammatory drugs or oral corticosteroids, events and adverse effects, calls to the physician, and hospital visits. The sample was homogeneous at baseline, and there were no withdrawals. Improvement was observed in both groups in relation to T0, but no statistically significant differences between groups were observed regarding all variables at the time points studied. The Sm/TH group exhibited more adverse effects at T1 (p<0.05), but these were mild and transitory. No severe adverse effects were reported during follow-up. Intra-articular injection of Samarium(153)-particulate hydroxyapatite (15 mCi) with 40 mg of triamcinolone hexacetonide is not superior to triamcinolone hexacetonide alone for the treatment of knee synovitis in patients with rheumatoid arthritis at 1 y of follow-up.

  13. High-rate activated sludge system for carbon management--Evaluation of crucial process mechanisms and design parameters.

    PubMed

    Jimenez, Jose; Miller, Mark; Bott, Charles; Murthy, Sudhir; De Clippeleir, Haydee; Wett, Bernhard

    2015-12-15

    The high-rate activated sludge (HRAS) process is a technology suitable for the removal and redirection of organics from wastewater to energy generating processes in an efficient manner. A HRAS pilot plant was operated under controlled conditions resulting in concentrating the influent particulate, colloidal, and soluble COD to a waste solids stream with minimal energy input by maximizing sludge production, bacterial storage, and bioflocculation. The impact of important process parameters such as solids retention time (SRT), hydraulic residence time (HRT) and dissolved oxygen (DO) levels on the performance of a HRAS system was demonstrated in a pilot study. The results showed that maximum removal efficiencies of soluble COD were reached at a DO > 0.3 mg O2/L, SRT > 0.5 days and HRT > 15 min which indicates that minimizing the oxidation of the soluble COD in the high-rate activated sludge process is difficult. The study of DO, SRT and HRT exhibited high degree of impact on the colloidal and particulate COD removal. Thus, more attention should be focused on controlling the removal of these COD fractions. Colloidal COD removal plateaued at a DO > 0.7 mg O2/L, SRT > 1.5 days and HRT > 30 min, similar to particulate COD removal. Concurrent increase in extracellular polymers (EPS) production in the reactor and the association of particulate and colloidal material into sludge flocs (bioflocculation) indicated carbon capture by biomass. The SRT impacted the overall mass and energy balance of the high-rate process indicating that at low SRT conditions, lower COD mineralization or loss of COD content occurred. In addition, the lower SRT conditions resulted in higher sludge yields and higher COD content in the WAS. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Development of Test Protocols for International Space Station Particulate Filters

    NASA Technical Reports Server (NTRS)

    Vijayakumar, R.; Green, Robert D.; Agui, Juan H.

    2015-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing can be applied to conducting acceptance testing and inventory testing for future manned exploration programs with air revitalization filtration needs, possibly even for in-situ filter element integrity testing for extensively long-duration missions. We plan to address the unique needs for test protocols for crewed spacecraft particulate filters by preparing the initial version of a standard, to be documented as a NASA Technical Memorandum (TM).

  15. Effects of particulate oxidation catalyst on unregulated pollutant emission and toxicity characteristics from heavy-duty diesel engine.

    PubMed

    Feng, Xiangyu; Ge, Yunshan; Ma, Chaochen; Tan, Jianwei

    2015-01-01

    To evaluate the effects of particulate oxidation catalyst (POC) on unregulated pollutant emission and toxicity characteristics, polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs), soot, soluble organic fractions (SOF) and sulphate emissions emitted from a heavy-duty diesel engine retrofitted with a POC were investigated on a diesel bench. The particulate matter (PM) in the exhaust was collected by Teflon membrane, and the PAHs and VOCs were analysed by a gas chromatography/mass spectrometer (GC/MS). The results indicate that the POC exhibits good performance on the emission control of VOCs, PAHs and PM. The POC and the diesel particulate filters (DPF) both show a good performance on reducing the VOCs emission. Though the brake-specific emission (BSE) reductions of the total PAHs by the POC were lower than those by the DPF, the POC still removed almost more than 50% of the total PAHs emission. After the engine was retrofitted with the POC, the reductions of the PM mass, SOF and soot emissions were 45.2-89.0%, 7.8-97.7% and 41.7-93.3%, respectively. The sulphate emissions decreased at low and medium loads, whereas at high load, the results were contrary. The PAHs emissions were decreased by 32.4-69.1%, and the contributions of the PAH compounds were affected by the POC, as well as by load level. The benzo[a]pyrene equivalent (BaPeq) of PAHs emissions were reduced by 35.9-97.6% with the POC. The VOCs emissions were reduced by 21.8-94.1% with the POC, and the reduction was more evident under high load.

  16. Mobile Particulate Emission Measurements of New York City Transit Buses and Other in use Vehicles

    NASA Astrophysics Data System (ADS)

    Jayne, J. T.; Canagaratna, M.; Herndon, S.; Shorter, J.; Zahniser, M.; Kolb, C.; Williams, L.; Worsnop, D.; Drewnick, F.; Demerjian, K. L.; Lanni, T.

    2002-12-01

    Emissions from both diesel and gasoline powered motor vehicles are a significant source of particulate (PM2.5) and trace gas pollution, especially in urban environments. Emission characterizations of motor vehicles can be performed using a dynamometer but these studies make fleet characterization impractical. Few studies have been performed which characterize emissions from in-use vehicles using a mobile sampling platform. This work describes application of new technology instrumentation for rapid (1-5 second) and real-time characterization of both gas and particulate emissions from in-use vehicles and is part of the PM2.5 Technology Assessment and Characterization Study in New York (PMTACS-NY). An aerosol mass spectrometer (AMS) and a tunable infrared laser differential absorption spectrometer (TILDAS) system were deployed on the Aerodyne Research mobile laboratory designed to "chase" target vehicles in and around the New York City area and measure their emissions under actual driving conditions. The AMS provides particle size and composition information for volatile and semi-volatile matter (0.03 - 1 um) while the TILDAS system was configured to measure NO, NO2, CO, CH4, SO2 and formaldehyde. In addition to a global positioning system, an ELPI and a condensation particle counter, the mobile laboratory was also equipped with a Licor CO2 monitor to allow emission indices to be computed for the targeted vehicles. Emission indices for both particulate and trace gases correlated with engine type are reported for a representative fraction of the NYC Metropolitan Transit Authority (MTA) bus fleet in an effort to characterize new emission control technologies currently implemented by the NYC MTA.

  17. Systems and methods for controlling diesel engine emissions

    DOEpatents

    Webb, Cynthia Chaffin; Weber, Phillip Anthony; Khair, Magdi K.

    2004-06-01

    Systems and methods for controlling diesel engine emissions, including, for example, oxides of nitrogen emissions, particulate matter emissions, and the like. The emission control system according to this invention is provided in the exhaust passageway of a diesel engine and includes a catalyst-based particulate filter; and first and second lean NO.sub.x trap systems coupled to the catalyst-based particulate filter. The first and second lean NO.sub.x trap systems are arranged in a parallel flow configuration with each other. Each of the first and second lean NO.sub.x trap systems include a carbon monoxide generating catalyst device, a sulfur trap device, a lean NO.sub.x device, a supplemental fuel injector device, and a plurality of flow diverter devices.

  18. Suspended particulate matter determines physical speciation of Fe, Mn, and trace metals in surface waters of Loire watershed.

    PubMed

    Baalousha, Mohamed; Stoll, Serge; Motelica-Heino, Mikaël; Guigues, Nathalie; Braibant, Gilles; Huneau, Frédéric; Le Coustumer, Philippe

    2018-02-10

    This study investigates the spatiotemporal variability of major and trace elements, dissolved organic carbon (DOC), total dissolved solids (TDS), and suspended particulate matter (SPM) in surface waters of several hydrosystems of the Loire River watershed in France. In particular, this study aims to delineate the impact of the abovementioned water physicochemical parameters on natural iron and manganese physical speciation (homoaggregation/heteroaggregation) among fine colloidal and dissolved (< 10 nm), colloidal (10-450 nm) and particulate (> 450 nm) phases in Loire River watershed. Results show that the chemistry of the Loire River watershed is controlled by two end members: magmatic and metamorphic petrographic context on the upper part of the watershed; and sedimentary rocks for the middle and low part of the Loire. The percentage of particulate Fe and Mn increased downstream concurrent with the increase in SPM and major cations concentration, whereas the percentage of colloidal Fe and Mn decreased downstream. Transmission electron microscopy analyses of the colloidal and particulate fractions (from the non-filtered water sample) revealed that heteroaggregation of Fe and Mn rich natural nanoparticles and natural organic matter to the particulate phase is the dominant mechanism. The heteroaggregation controls the partitioning of Fe and Mn in the different fractions, potentially due to the increase in the ionic strength, and divalent cations concentration downstream, and SPM concentration. These findings imply that SPM concentration plays an important role in controlling the fate and behavior of Fe and Mn in various sized fractions. Graphical abstract Physical speciation by heteroaggregation of (Fe-Mn) compounds: high [SPM] → [Fe-Mn] particulate faction; low {SPM] → [Fe-Mn] colloid-dissolved fraction.

  19. [Methodical problems of monitoring of fine particulate matters in atmospheric air of residential areas].

    PubMed

    Karelin, A O; Lomtev, A Yu; Mozzhukhina, N A; Yeremin, G B; Nikonov, V A

    Inhalation of fine particulate matters (PM and PM ) poses a threat for the health of population. Purpose of the study the analysis of the monitoring of fine particulate matters in the atmospheric air of Saint-Petersburg and identification of the main problems of the monitoring. Research methods methods of scientific hypothetical deductive cognition, sanitary-statistical methods, general logical methods and approaches of researches: analysis, synthesis, abstracting, generalization, induction. Results. The article represents the analysis of the monitoring of fine particulate matters in the atmospheric air of Saint- Petersburg. Only 11 in automatic monitoring stations out of 22 there is carried out the control of fine particulate matters: in 7 - PM and PM, and in 4 - PM The average year concentrations were below MAC in all the stations. The maximum concentrations achieved 3 MAC, but the repeatance of cases of exceedence of concentrations more than MAC was very rare. On the average of the city concentrations of PM were decreased from 0,8 MAC in 2006 and 1,1 MAC in 2007 to 0,5 MAC in 2013-14. The executed analysis revealed main problems of the monitoring of fine particulate matters in the Russian Federation. They include the absence of the usage 1of the officially approved methods of controlling of PM and PM in the atmospheric air until March 1, 2016, lack of the modern equipment for measurement of fine particulate matters. Conclusions. Therefore, the state of the monitoring of fine particulate matters in the atmospheric air in the Russian Federation fails to be satisfactory. It is necessary to improve system of the monitoring, create modern Russian appliances, methods and means for measurement of fine particulate matters concentrations in the atmospheric air.

  20. 40 CFR 63.9913 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... must I use to demonstrate initial compliance with the emission limits for particulate matter and PM10... compliance with the emission limits for particulate matter and PM10? (a) You must conduct each performance... determine compliance with the applicable emission limits for particulate matter in Table 1 to this subpart...

  1. 40 CFR 63.9913 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... must I use to demonstrate initial compliance with the emission limits for particulate matter and PM10... compliance with the emission limits for particulate matter and PM10? (a) You must conduct each performance... determine compliance with the applicable emission limits for particulate matter in Table 1 to this subpart...

  2. Garment selection for cleanrooms and controlled environments for spacecraft

    NASA Astrophysics Data System (ADS)

    Watts, Ethel J.

    Strict contamination control practices are exercised throughout the lifetime of a spacecraft in order to satisfy the performance requirements of the system. Spacecraft materials are carefully selected to have low outgassing values and particulate deposition. Parts are cleaned, and the vehicle is assembled in cleanrooms and work stations having controlled environments. Specifications are examined which govern the selection of special items of clothing designed to protect spacecraft from contaminants released by personnel and by garments. Special clothing includes coveralls, footwear, and head/face covers. Garments appropriate for both hazardous (meltproof as well as flame resistant), and nonhazardous operations are described.

  3. 40 CFR 52.776 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Approval—The complete Indiana plan for Clark, Dearborn, Dubois, Marion (except for coke batteries), St..., Vandenburgh County; 6-1-17, Clark County; 6-1-18, St. Joseph County; 6-2, Particulate Emissions Limitations...

  4. 40 CFR 52.776 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Approval—The complete Indiana plan for Clark, Dearborn, Dubois, Marion (except for coke batteries), St..., Vandenburgh County; 6-1-17, Clark County; 6-1-18, St. Joseph County; 6-2, Particulate Emissions Limitations...

  5. Interaction of PM2.5 airborne particulates with ZnO and TiO2 nanoparticles and their effect on bacteria.

    PubMed

    Baysal, Asli; Saygin, Hasan; Ustabasi, Gul Sirin

    2017-12-21

    A significant knowledge gap in nanotechnology is the absence of standardized protocols for examining and comparison the effect of metal oxide nanoparticles on different environment media. Despite the large number of studies on ecotoxicity of nanoparticles, most of them disregard the particles physicochemical transformation under real exposure conditions and interaction with different environmental components like air, soil, water, etc. While one of the main exposure ways is inhalation and/or atmosphere for human and environment, there is no investigation between airborne particulates and nanoparticles. In this study, some metal oxide nanoparticle (ZnO and TiO 2 ) transformation and behavior in PM2.5 air particulate media were examined and evaluated by the influence on nanoparticle physicochemical properties (size, surface charge, surface functionalization) and on bacterium (Gram-positive Bacillus subtilis, Staphylococcus aureus/Gram-negative Escherichia coli, Pseudomonas aeruginosa bacteria) by testing in various concentrations of PM2.5 airborne particulate media to contribute to their environmental hazard and risk assessment in atmosphere. PM2.5 airborne particulate media affected their toxicity and physicochemical properties when compared the results obtained in controlled conditions. ZnO and TiO 2 surfaces were functionalized mainly with sulfoxide groups in PM2.5 air particulates. In addition, tested particles were not observed to be toxic in controlled conditions. However, these were observed inhibition in PM2.5 airborne particulates media by the exposure concentration. These observations and dependence of the bacteria viability ratio explain the importance of particulate matter-nanoparticle interaction.

  6. 40 CFR 60.46b - Compliance and performance test methods and procedures for particulate matter and nitrogen oxides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and procedures for particulate matter and nitrogen oxides. 60.46b Section 60.46b Protection of... NEW STATIONARY SOURCES Standards of Performance for Industrial-Commercial-Institutional Steam... nitrogen oxides. (a) The PM emission standards and opacity limits under § 60.43b apply at all times except...

  7. PRELIMINARY RESULTS OF EPA'S PERFORMANCE EVALUATION OF FEDERAL REFERENCE METHODS AND FEDERAL EQUIVALENT METHODS FOR COARSE PARTICULATE MATTER

    EPA Science Inventory

    The main objective of this study is to evaluate the performance of sampling methods for potential use as a Federal Reference Method (FRM) capable of providing an estimate of coarse particle (PMc: particulate matter with an aerodynamic diameter between 2.5 µm and 10 µm) ...

  8. DETERMINING COARSE PARTICULATE MATTER CONCENTRATIONS: A PERFORMANCE EVALUATION OF CANDIDATE METHODOLOGIES - STUDY DESIGN AND RESULTS FROM THE RTP EQUIPMENT SHAKEDOWN

    EPA Science Inventory

    The main objective of this study is to evaluate the performance of candidate sampling methods for potential use as a Federal Reference Method (FRM) capable of providing an estimate of coarse particle (PMc: particulate matter with an aerodynamic diameter between 2.5 um and 10 um...

  9. U.S./U.S.S.R. SYMPOSIUM ON PARTICULATE CONTROL (3RD) HELD AT SUZDAL, U.S.S.R. ON SEPTEMBER 10-12, 1979

    EPA Science Inventory

    The proceedings document the Third U.S./U.S.S.R. Symposium on Particulate Control, September 10-12, 1979, in Suzdal, U.S.S.R. Papers covered such topics as: predicting back-corona formation and fly ash resistivity, improved electrostatic precipitator (ESP) mathematical modeling, ...

  10. Cyclone separator having boundary layer turbulence control

    DOEpatents

    Krishna, Coimbatore R.; Milau, Julius S.

    1985-01-01

    A cyclone separator including boundary layer turbulence control that is operable to prevent undue build-up of particulate material at selected critical areas on the separator walls, by selectively varying the fluid pressure at those areas to maintain the momentum of the vortex, thereby preventing particulate material from inducing turbulence in the boundary layer of the vortical fluid flow through the separator.

  11. Mechanisms and Factors Regulating the Uptake and Toxicity of Heavy Metals in Phytoplankton

    DTIC Science & Technology

    1997-09-30

    Laboratory, National Marine Fisheries Service, NOAA, Beaufort, NC 28516 Phone: 919/728-8754; Fax: 919/728-8784 E-mail: BSUNDA@HATTERAS.BEA.NMFS.GOV Award...composition of phytoplankton communities in coastal waters and to determine the role of algal metal uptake in controlling the particulate removal and...7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) National Oceanic and Atmospheric Administration (NOAA),National Marine Fisheries Service,325

  12. Importance of filter’s microstructure in dynamic filtration modeling of gasoline particulate filters (GPFs): Inhomogeneous porosity and pore size distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Jian; Stewart, Mark L.; Zelenyuk, Alla

    The state-of-the-art multiscale modeling of GPFs including channel scale, wall scale, and pore scale is described. The microstructures of two GPFs were experimentally characterized. The pore size distributions of the GPFs were determined by mercury porosimetry. The porosity was measured by X-ray computed tomography (CT) and found to be inhomogeneous across the substrate wall. The significance of pore size distribution with respect to filtration performance was analyzed. The predictions of filtration efficiency were improved by including the pore size distribution in the filtration model. A dynamic heterogeneous multiscale filtration (HMF) model was utilized to simulate particulate filtration on a singlemore » channel particulate filter with realistic particulate emissions from a spark-ignition direct-injection (SIDI) gasoline engine. The dynamic evolution of filter’s microstructure and macroscopic filtration characteristics including mass- and number-based filtration efficiencies and pressure drop were predicted and discussed. The microstructure of the GPF substrate including inhomogeneous porosity and pore size distribution is found to significantly influence local particulate deposition inside the substrate and macroscopic filtration performance and is recommended to be resolved in the filtration model to simulate and evaluate the filtration performance of GPFs.« less

  13. HIGH-TEMPERATURE AND HIGH-PRESSURE PARTICULATE CONTROL REQUIREMENTS

    EPA Science Inventory

    The report reviews and evaluates high-temperature and high-pressure particulate cleanup requirements of existing and proposed energy processes. The study's aims are to define specific high-temperature and high-pressure particle removal problems, to indicate potential solutions, a...

  14. Setting and Reviewing Standards to Control Particulate Matter (PM) Pollution

    EPA Pesticide Factsheets

    The Clean Air Act requires EPA to set national air quality standards for particulate matter, and to periodically review the standards to ensure that they provide adequate health and environmental protection, updating those standards as necessary.

  15. Transportation conformity particulate matter hot-spot air quality modeling.

    DOT National Transportation Integrated Search

    2013-07-01

    In light of the new development in particulate matter (PM) hot-spot regulations and Illinois Department : of Transportation (IDOT)s National Environmental Policy Act (NEPA) documentation requirements, : this project is intended to (1) perform and ...

  16. 40 CFR 60.1815 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false How do I monitor the temperature of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate a device to continuously measure the temperature of the...

  17. 40 CFR 60.1815 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false How do I monitor the temperature of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate a device to continuously measure the temperature of the...

  18. 40 CFR 60.1815 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false How do I monitor the temperature of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate a device to continuously measure the temperature of the...

  19. Low exhaust temperature electrically heated particulate matter filter system

    DOEpatents

    Gonze, Eugene V [Pinckney, MI; Paratore, Jr., Michael J.; Bhatia, Garima [Bangalore, IN

    2012-02-14

    A system includes a particulate matter (PM) filter, a sensor, a heating element, and a control module. The PM filter includes with an upstream end that receives exhaust gas, a downstream end and multiple zones. The sensor detects a temperature of the exhaust gas. The control module controls current to the heating element to convection heat one of the zones and initiate a regeneration process. The control module selectively increases current to the heating element relative to a reference regeneration current level when the temperature is less than a predetermined temperature.

  20. Fine particulates over South Asia: Review and meta-analysis of PM2.5 source apportionment through receptor model.

    PubMed

    Singh, Nandita; Murari, Vishnu; Kumar, Manish; Barman, S C; Banerjee, Tirthankar

    2017-04-01

    Fine particulates (PM 2.5 ) constitute dominant proportion of airborne particulates and have been often associated with human health disorders, changes in regional climate, hydrological cycle and more recently to food security. Intrinsic properties of particulates are direct function of sources. This initiates the necessity of conducting a comprehensive review on PM 2.5 sources over South Asia which in turn may be valuable to develop strategies for emission control. Particulate source apportionment (SA) through receptor models is one of the existing tool to quantify contribution of particulate sources. Review of 51 SA studies were performed of which 48 (94%) were appeared within a span of 2007-2016. Almost half of SA studies (55%) were found concentrated over few typical urban stations (Delhi, Dhaka, Mumbai, Agra and Lahore). Due to lack of local particulate source profile and emission inventory, positive matrix factorization and principal component analysis (62% of studies) were the primary choices, followed by chemical mass balance (CMB, 18%). Metallic species were most regularly used as source tracers while use of organic molecular markers and gas-to-particle conversion were minimum. Among all the SA sites, vehicular emissions (mean ± sd: 37 ± 20%) emerged as most dominating PM 2.5 source followed by industrial emissions (23 ± 16%), secondary aerosols (22 ± 12%) and natural sources (20 ± 15%). Vehicular emissions (39 ± 24%) also identified as dominating source for highly polluted sites (PM 2.5 >100 μgm -3 , n = 15) while site specific influence of either or in combination of industrial, secondary aerosols and natural sources were recognized. Source specific trends were considerably varied in terms of region and seasonality. Both natural and industrial sources were most influential over Pakistan and Afghanistan while over Indo-Gangetic plain, vehicular, natural and industrial emissions appeared dominant. Influence of vehicular emission was found single dominating source over southern part while over Bangladesh, both vehicular, biomass burning and industrial sources were significant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. The photo-oxidation of automobile emissions: measurements of the transformation products and their mutagenic activity

    NASA Astrophysics Data System (ADS)

    Kleindienst, Tadeusz E.; Smith, David F.; Hudgens, Edward E.; Snow, Richard F.; Perry, Erica; Claxton, Larry D.; Bufalini, Joseph J.; Black, Francis M.; Cupitt, Larry T.

    Dilute mixtures of automobile emissions (comprising 50% exhaust and 50% surrogate evaporative emissions) were irradiated in a 22.7 m 3 smog chamber and tested for mutagenic activity by using a variant of the Ames test. The exhaust was taken from a single vehicle, a 1977 Ford Mustang equipped with a catalytic converter. Irradiated and nonirradiated gas-phase emissions were used in exposures of the bacteria, Salmonella typhimurium, strains TA100 and TA98. A single set of vehicular operating conditions was used to perform multiple exposures. The mutagenic activities of extracts from the particulate phase were also measured with the standard plate incorporation assay. (In most experiments only direct-acting mutagenic compounds were measured.) The gas-phase data for TA100 and TA98 showed increased activity for the irradiated emissions when compared to the nonirradiated mixture, which exhibited negligible activity with respect to the control values. The particulate phase for both the irradiated and nonirradiated mixtures showed negligible activity when results were compared to the control values for both strains. However, the experimental conditions limited the amount of extractable mass which could be collected in the particulate phase. The measured activities from the gas phase and particulate phase were converted to the number of revertants per cubic meter of effluent (i.e. the mutagenic density) to compare the contributions of each of these phases to the total mutagenic activity for each strain. Under the experimental conditions of this study, the mutagenic density of the gas-phase component of the irradiated mixture contributed approximately two orders of magnitude more of the total TA100 activity than did the particulate phase. For TA98 the gas-phase component contributed approximately one order of magnitude more. However, caution must be exercised in extrapolating these results to urban atmospheres heavily impacted by automotive emissions, because the bacterial mutagenicity assay was used as a screening method, and additional assays using mammalian systems have not yet been conducted. In addition, only limited number of conditions were able to be tested. The significance and limitations of the results are discussed.

  2. School Environmental Intervention to Reduce Particulate Pollutant Exposures for Children with Asthma.

    PubMed

    Jhun, Iny; Gaffin, Jonathan M; Coull, Brent A; Huffaker, Michelle F; Petty, Carter R; Sheehan, William J; Baxi, Sachin N; Lai, Peggy S; Kang, Choong-Min; Wolfson, Jack M; Gold, Diane R; Koutrakis, Petros; Phipatanakul, Wanda

    Home-based interventions to improve indoor air quality have demonstrated benefits for asthma morbidity, yet little is known about the effect of environmental interventions in the school setting. We piloted the feasibility and effectiveness of a classroom-based air cleaner intervention to reduce particulate pollutants in classrooms of children with asthma. In this pilot randomized controlled trial, we assessed the effect of air cleaners on indoor air particulate pollutant concentrations in 18 classrooms (9 control, 9 intervention) in 3 urban elementary schools. We enrolled 25 children with asthma (13 control, 12 intervention) aged 6 to 10 years. Classroom air pollutant measurements and spirometry were completed once before and twice after randomization. Asthma symptoms were surveyed every 3 months. Baseline classroom levels of fine particulate matter (particulate matter with diameter of <2.5 μm [PM 2.5 ]) and black carbon (BC) were 6.3 and 0.41 μg/m 3 , respectively. When comparing the intervention to the control group, classroom PM 2.5 levels were reduced by 49% and 42% and BC levels were reduced by 58% and 55% in the first and second follow-up periods, respectively (P < .05 for all comparisons). When comparing the children randomized to intervention and control classrooms, there was a modest improvement in peak flow, but no significant changes in forced expiratory volume in 1 second (FEV 1 ) and asthma symptoms. In this pilot study, a classroom-based air cleaner intervention led to significant reductions in PM 2.5 and BC. Future large-scale studies should comprehensively evaluate the effect of school-based environmental interventions on pediatric asthma morbidity. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. PARTICULATE EMISSION CONTROL

    EPA Science Inventory

    Particle or particulate matter is defined as any finely divided solid or liquid material, other than uncombined water, emitted to the ambient air as measured by applicable reference methods, or an equivalent or alternative method, or by a test method specified in 40CFR50.

  4. Silicone-oil-based subvisible particles: their detection, interactions, and regulation in prefilled container closure systems for biopharmaceuticals.

    PubMed

    Felsovalyi, Flora; Janvier, Sébastien; Jouffray, Sébastien; Soukiassian, Hervé; Mangiagalli, Paolo

    2012-12-01

    Recent increased regulatory scrutiny concerning subvisible particulates (SbVPs) in parenteral formulations of biologics has led to the publication of numerous articles about the sources, characteristics, implications, and approaches to monitoring and detecting SbVPs. Despite varying opinions on the level of associated risks and method of regulation, nearly all industry scientists and regulators agree on the need for monitoring and reporting visible and subvisible particles. As prefillable drug delivery systems have become a prominent packaging option, silicone oil, a common primary packaging lubricant, may play a role in the appearance of particles. The goal of this article is to complement the current SbVP knowledge base with new insights into the evolution of silicone-oil-related particulates and their interactions with components in prefillable systems. We propose a "toolbox" for improved silicone-oil-related particulate detection and enumeration, and discuss the benefits and limitations of approaches for lowering and controlling silicone oil release in parenterals. Finally, we present surface cross-linking of silicone as the recommended solution for achieving significant SbVP reduction without negatively affecting functional performance. Copyright © 2012 Wiley Periodicals, Inc.

  5. Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions

    DTIC Science & Technology

    2015-12-30

    FINAL REPORT Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM...Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions 6. AUTHOR(S) E. Corporan, M...report contains color. 14. ABSTRACT This project consists of demonstrating the performance and viability of two devices to condition aircraft turbine

  6. Effects of Contamination Upon the Performance of X-Ray Telescopes

    NASA Technical Reports Server (NTRS)

    O'Dell, Stephen L.; Elsner, Ronald F.; Oosterbroek, Tim

    2010-01-01

    Particulate and molecular contamination can each impact the performance of x-ray telescope systems. Furthermore, any changes in the level of contamination between on-ground calibration and in-space operation can compromise the validity of the calibration. Thus, it is important to understand the sensitivity of telescope performance, especially the net effective area and the wings of the point spread function to contamination. Here, we quantify this sensitivity and discuss the flow-down of science requirements to contamination-control requirements. As an example, we apply this methodology to the International X-ray Observatory (IXO), currently under joint study by ESA, JAXA, and NASA.

  7. Effects of contamination upon the performance of x-ray telescopes

    NASA Astrophysics Data System (ADS)

    O'Dell, Stephen L.; Elsner, Ronald F.; Oosterbroek, Tim

    2010-07-01

    Particulate and molecular contamination can each impact the performance of x-ray telescope systems. Furthermore, any changes in the level of contamination between on-ground calibration and in-space operation can compromise the validity of the calibration. Thus, it is important to understand the sensitivity of telescope performance---especially the net effective area and the wings of the point spread function---to contamination. Here, we quantify this sensitivity and discuss the flow-down of science requirements to contamination-control requirements. As an example, we apply this methodology to the International X-ray Observatory (IXO), currently under joint study by ESA, JAXA, and NASA.

  8. Development of Test Protocols for International Space Station Particulate Filters

    NASA Technical Reports Server (NTRS)

    Green, Robert D.; Vijayakumar, R.; Agui, Juan H.

    2014-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High- Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. Over the years, the service life of these filters has been re-evaluated based on limited post-flight tests of returned filters and risk factors. On earth, a well designed and installed HEPA filter will last for several years, e.g. in industrial and research clean room applications. Test methods for evaluating these filters are being developed on the basis of established test protocols used by the industry and the military. This paper will discuss the test methods adopted and test results on prototypes of the ISS filters. The results will assist in establishing whether the service life can be extended for these filters. Results from unused filters that have been in storage will also be presented to ascertain the shelf life and performance deterioration, if any and determine if the shelf life may be extended.

  9. INVESTIGATING THE PREFERENTIAL DISSOLUTION OF LEAD FROM SOLDER PARTICULATES

    EPA Science Inventory

    During a building corrosion control study, bottles containing acid-preserved water samples with high levels of lead often had particulate material on the bottom. Scanning electron microscope analysis of the particles showed the presence of tin and the absence of lead, indicating ...

  10. Bayesian Hierarchical Modeling of Cardiac Response to Particulate Matter Exposure

    EPA Science Inventory

    Studies have linked increased levels of particulate air pollution to decreased autonomic control, as measured by heart rate variability (HRV), particularly in populations such as the elderly. In this study, we use data obtained from the 1998 USEPA epidemiology-exposure longitudin...

  11. Gelatin Scaffolds with Controlled Pore Structure and Mechanical Property for Cartilage Tissue Engineering.

    PubMed

    Chen, Shangwu; Zhang, Qin; Nakamoto, Tomoko; Kawazoe, Naoki; Chen, Guoping

    2016-03-01

    Engineering of cartilage tissue in vitro using porous scaffolds and chondrocytes provides a promising approach for cartilage repair. However, nonuniform cell distribution and heterogeneous tissue formation together with weak mechanical property of in vitro engineered cartilage limit their clinical application. In this study, gelatin porous scaffolds with homogeneous and open pores were prepared using ice particulates and freeze-drying. The scaffolds were used to culture bovine articular chondrocytes to engineer cartilage tissue in vitro. The pore structure and mechanical property of gelatin scaffolds could be well controlled by using different ratios of ice particulates to gelatin solution and different concentrations of gelatin. Gelatin scaffolds prepared from ≥70% ice particulates enabled homogeneous seeding of bovine articular chondrocytes throughout the scaffolds and formation of homogeneous cartilage extracellular matrix. While soft scaffolds underwent cellular contraction, stiff scaffolds resisted cellular contraction and had significantly higher cell proliferation and synthesis of sulfated glycosaminoglycan. Compared with the gelatin scaffolds prepared without ice particulates, the gelatin scaffolds prepared with ice particulates facilitated formation of homogeneous cartilage tissue with significantly higher compressive modulus. The gelatin scaffolds with highly open pore structure and good mechanical property can be used to improve in vitro tissue-engineered cartilage.

  12. Evaluation of low-cost aluminum composites for aircraft engine structural applications

    NASA Technical Reports Server (NTRS)

    Mcdanels, D. L.; Signorelli, R. A.

    1983-01-01

    Panels of discontinuous SiC composites, with several aluminum matrices, were fabricated and evaluated. Modulus, yield strength and tensile strength results indicated that the properties of composites containing SiC whisker, nodule or particulate reinforcements were similar. The modulus of the composites was controlled by the volume percentage of the SiC reinforcement content, while the strength and ductility were controlled by both the reinforcement content and the matrix alloy. The feasibility of fabricating structural shapes by both wire performs and direct casting was demonstrated for Al2O3/Al composites. The feasibility of fabricating high performance composites into structural shapes by low pressure hot molding was demonstrated for B4C-coated B/Al composites.

  13. Exploring the piezoelectric performance of PZT particulate-epoxy composites loaded in shear

    NASA Astrophysics Data System (ADS)

    Van Loock, F.; Deutz, D. B.; van der Zwaag, S.; Groen, W. A.

    2016-08-01

    The active and passive piezoelectric response of lead zirconium titanate (PZT)-epoxy particulate composites loaded in shear is studied using analytical models, a finite element model and by experiments. The response is compared to that of the same composites when loaded in simple tension. Analogously to bulk PZT, particulate PZT-polymer composites loaded in shear show higher piezoelectric charge coefficient (d 15) and energy density figure of merit (FOM15) values compared to simple tension (d 33) and (FOM33). This outcome demonstrates the as-yet barely explored potential of piezoelectric particulate composites for optimal strain energy harvesting when activated in shear.

  14. Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions

    DTIC Science & Technology

    2017-03-06

    WP-201317) Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non -volatile Particulate Matter (PM...Engine Volatile and Non -Volatile Particulate Matter (PM) Emissions 6. AUTHOR(S) E. Corporan, M. DeWitt, C. Klingshirn, M.D. Cheng, R. Miake-Lye, J. Peck...the performance and viability of two devices to condition aircraft turbine engine exhaust to allow the accurate measurement of total (volatile and non

  15. 78 FR 19991 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Motor Vehicle...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ... Environmental protection, Air pollution control, Incorporation by reference, Nitrogen dioxide, Particulate... Promulgation of Air Quality Implementation Plans; Pennsylvania; Motor Vehicle Emissions Budgets for the Pennsylvania Counties in the Philadelphia-Wilmington, PA-NJ-DE 1997 Fine Particulate Matter Nonattainment Area...

  16. Particulates and fine dust removal: processes and equipment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sittig, M.

    1977-01-01

    Particulates and fine dust created by man's activities contribute significantly to all major aspects of air pollution. While the generation of natural fine dusts is also very large in some parts of the earth, industrially generated, particle-loaded air emissions may push the particulate level to a point where acceptable air quality standards are exceeded continuously. How to reduce such emissions at the source, and what processes and equipment to use, is the subject of this book, which is based on reports of federally-financed air pollution studies as well as U.S. patents. Following an introduction with an overview of industrial particulatemore » emissions, emission data and emission control processes are discussed for the following specific industries: airlines; asphalt; cement; coal; electric utilities; ferrous metals; fertilizer; food; forest products; paper; chemicals; nonferrous metals; nuclear; petroleum refining; stone and clay; and textiles. Conventional and innovative particle removal devices are described. The disposal of collected particles is discussed. The economic and energy consumption aspects of particulate control are presented. (LCL)« less

  17. Biological effects of compressive forces exerted on particulate bone grafts during socket preservation: animal study.

    PubMed

    Delgado-Ruiz, Rafael; Romanos, Georgios E; Alexandre Gerhke, Sergio; Gomez-Moreno, Gerardo; Maté-Sánchez de Val, José Eduardo; Calvo-Guirado, José Luis

    2016-08-02

    To compare different compressive forces exerted on a particulate graft material during socket preservation and their effects on bone regeneration. Six male dogs were used. The second, third, and fourth premolars, and the first molar were extracted bilaterally at the lower jaws. A particulate synthetic biphasic grafting material (60% HA and 40% β-tricalcium phosphate) was used. Three different standardized compressive forces were applied randomly during the socket preservation. The sample was divided into four experimental groups Test A (10 g), Test B (50 g), Test C (200 g), and Control (empty sockets). Collagen membranes were placed, and primary closure was obtained. Two months after the surgery the animals were sacrificed, and histomorphometric analysis of non-decalcified samples was performed at the coronal, middle, and apical thirds. Grafted sockets resulted in higher bony contour (3 ± 0.43 mm 2 ; P < 0.05). The particles penetrated up to the apical third in the group C but not in the other test groups and controls (P < 0.05). The percentage of new bone were higher at the coronal and apical thirds for Controls and group C compared to A and B groups (P < 0.05). The residual graft was higher for group C (53 ± 1.4%), followed by group B (45 ± 3.1%) and group A (35 ± 1.9%; P < 0.05). The percentages of connective tissue were higher at the middle third without differences between groups (P > 0.05). Within the limitations of this experimental animal study, it might be concluded that grafted sockets compressed with 200 g force will have higher bony contours; higher compressive forces facilitate the penetration of the particulate graft material into the apical area of the socket and results in more bone formation at the coronal, middle, and apical thirds. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Source contributions of fine particulate matter during one winter haze episodes in Xi'an, China

    NASA Astrophysics Data System (ADS)

    Yang, X.; Wu, Q.

    2017-12-01

    Long-term exposure to high levels of fine particulate matter (PM2.5) is found to be associated with adverse effects on human health, ecological environment and climate change. Identification the major source regions of fine particulate matter are essential to proposing proper joint prevention and control strategies for heavy haze mitigation. In this work, the Comprehensive Air Quality Model with extensions (CAMx) together with the Particulate Source Apportionment Technology (PSAT) and the Weather Research and Forecast Model (WRF), have been applied to analyze the major source regions of PM2.5 in Xi'an during the heavy haze episodes in winter (29, December, 2016 - 5 January 2017), and the framework of the model system is shown in Fig. 1. Firstly, according to the model evaluation of the daily PM2.5 concentrations for the two months, the model has well performance, and the fraction of predictions within a factor of 2 of the observations (FAC2) is 84%, while the correlation coefficient (R) is 0.80 in Xi'an. By using the PSAT in CAMx model, a detailed source region contribution matrix is derived for all points within the Xi'an region and its six surrounding areas, and long-range regional transport. The results show that the local emission in Xi'an is the mainly sources at downtown area, which contributing 72.9% as shown in Fig.2, and the contribution rate of transportations between adjacent areas depends on wind direction. Meanwhile, three different suburban areas selected for detailed analysis in fine particles sources. Comparing to downtown area, the sources of suburban areas are more multiply, and the transportations make the contribution 40%-82%. In the suburban areas, regional inflows play an important role in the fine particles concentrations, indicating a strong need for regional joint emission control efforts. The results enhance the quantitative understanding of the PM2.5 source regions and provide a basis for policymaking to advance the control of pollution in Xi'an, China.

  19. Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.

    2016-01-01

    It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 milligrams per square meter, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems, however, vary considerably, notably within the aerospace industry. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

  20. Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.

    2016-01-01

    It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 mg/sq m, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems vary considerably. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

  1. Regional Background Fine Particulate Matter

    EPA Science Inventory

    A modeling system composed of the global model GEOS-Chem providing hourly lateral boundary conditions to the regional model CMAQ was used to calculate the policy relevant background level of fine particulate: matter. Simulations were performed for the full year of 2004 over the d...

  2. Electrically heated particulate filter with zoned exhaust flow control

    DOEpatents

    Gonze, Eugene V [Pinckney, MI

    2012-06-26

    A system includes a particulate matter (PM) filter that includes X zones. An electrical heater includes Y heater segments that are associated with respective ones of the X zones. The electrical heater is arranged upstream from and proximate with the PM filter. A valve assembly includes Z sections that are associated with respective ones of the X zones. A control module adjusts flow through each of the Z sections during regeneration of the PM filter via control of the valve assembly. X, Y and Z are integers.

  3. Is the Relation Between Ozone and Mortality Confounded by Chemical Components of Particulate Matter? Analysis of 7 Components in 57 US Communities

    PubMed Central

    Anderson, G. Brooke; Krall, Jenna R.; Peng, Roger D.; Bell, Michelle L.

    2012-01-01

    Epidemiologic studies have linked tropospheric ozone pollution and human mortality. Although research has shown that this relation is not confounded by particulate matter when measured by mass, little scientific evidence exists on whether confounding exists by chemical components of the particle mixture. Using mortality and particulate matter with aerodynamic diameter ≤2.5 µm (PM2.5) component data from 57 US communities (2000–2005), the authors investigate whether the ozone-mortality relation is confounded by 7 components of PM2.5: sulfate, nitrate, silicon, elemental carbon, organic carbon matter, sodium ion, and ammonium. Together, these components constitute most PM2.5 mass in the United States. Estimates of the effect of ozone on mortality were almost identical before and after controlling for the 7 components of PM2.5 considered (mortality increase/10-ppb ozone increase, before and after controlling: ammonium, 0.34% vs. 0.35%; elemental carbon, 0.36% vs. 0.37%; nitrate, 0.27% vs. 0.26%; organic carbon matter, 0.34% vs. 0.31%; silicon, 0.36% vs. 0.37%; sodium ion, 0.21% vs. 0.18%; and sulfate, 0.35% vs. 0.38%). Additionally, correlations were weak between ozone and each particulate component across all communities. Previous research found that the ozone-mortality relation is not confounded by particulate matter measured by mass; this national study indicates that the relation is also robust to control for specific components of PM2.5. PMID:23043133

  4. STATUS OF RESEARCH ON AIR QUALITY: MERCURY, TRACE ELEMENTS, AND PARTICULATE MATTER. (R827649)

    EPA Science Inventory

    The Air Quality Conference reviewed the state of science and policy on the pollutants mercury, trace elements, and particulate matter (PM) in the environment. Critical issues dealing with impacts on health and ecosystems, emission prevention and control, measurement methods, a...

  5. SOURCE SAMPLING FINE PARTICULATE MATTER: WOOD-FIRED INDUSTRIAL BOILER

    EPA Science Inventory

    The report provides a profile for a wood-fired industrial boiler equipped with a multistage electrostatic precipitator control device. Along with the profile of emissions of fine particulate matter of aerodynamic diameter of 2.5 micrometers or less (PM-2.5), data are also provide...

  6. HIGHLIGHTS FROM TECHNICAL MANUAL ON HOOD SYSTEM CAPTURE OF PROCESS FUGITIVE PARTICULATE EMISSIONS

    EPA Science Inventory

    The paper discusses a technical manual whose emphasis is on the design and evaluation of actual hood systems used to control various fugitive particulate emission sources. Engineering analyses of the most important hood types are presented to provide a conceptual understanding of...

  7. An evaluation of indoor and outdoor biological particulate matter (BioPM)

    EPA Science Inventory

    Monitoring of indoor and ambient particulate matter (PM) and the characterization of the content for biological aerosol concentrations has not been extensively performed. Samples from urban and rural North Carolina, and Denver, CO, were collected and analyzed as the goal of this ...

  8. AN EVALUATION OF THE PROTEIN MASS OF PARTICULATE MATTER

    EPA Science Inventory

    A comparison of ambient particulate matter mass concentrations with the total protein mass concentration has not been performed previously for North Carolina and was the goal of this study. The analysis of total protein mass was used as an all inclusive indicator of biologically ...

  9. Particulate Characterization and Control Evaluation for Carbon Fiber Composite Aircraft Crash Recovery Operations

    DTIC Science & Technology

    2010-03-01

    Advanced Composite Office, Wright-Patterson BEE Flight, and USAFSAM for their help procuring the materials and supplies needed to perform this study...through the cyclone. (Cohen & Charles S . McCammonn, 2001) The major limitation of the cyclone is that the cut curve of the cyclone does not precisely...If the pump is not precisely calibrated to the specified flow the cut point will be altered. (Cohen & Charles S . McCammonn, 2001) Once the sample

  10. Environmental Assessment for the Maintenance, Upgrade, and Construction of the Jet Fuel Distribution System, Edwards Air Force Base, California

    DTIC Science & Technology

    2009-01-01

    5c. PROGRAM ELEMENT NUMBER 6. AUTHOR (S) 5d. PROJECT NUMBER 5e. TASK NUMBER EIAP Control No. 07-0485 5f. WORK UNIT NUMBER 7. PERFORMING...chemical hazards such as fuel vapors, heavy metal paints, and asbestos particulates; venomous snakes; and potential exposure to hantavirus or valley...OCCUPATIONAL HEALTH Environmental hazards Personnel could be exposed to heat stress, venomous snakes, hantavirus from infected rodents, and valley

  11. Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Fosetyl-Aluminum in Airborne Particulate Matter

    PubMed Central

    Di Filippo, Patrizia; Riccardi, Carmela; Pomata, Donatella; Marsiglia, Riccardo; Console, Carla; Puri, Daniele

    2018-01-01

    Fosetyl-aluminum is a synthetic fungicide administered to plants especially to prevent diseases caused by the members of the Peronosporales and several Phytophthora species. Herein, we present a selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze residues of fosetyl-A1 in air particulate matter. This study was performed in perspective of an exposure assessment of this substance of health concern in environments where high levels of fosetly-Al, relatively to airborne particulate matter, can be found after spraying it. The cleanup procedure of the analyte, from sampled filters of atmospheric particulate matter, was optimized using a Strata X solid-phase extraction cartridge, after accelerated extraction by using water. The chromatographic separation was achieved using a polymeric column based on hydrophilic interaction in step elution with water/acetonitrile, whereas the mass spectrometric detection was performed in negative electrospray ionization. The proposed method resulted to be a simple, fast, and suitable method for confirmation purposes. PMID:29686933

  12. Effectiveness of Radiation Synovectomy with Samarium-153 Particulate Hydroxyapatite in Rheumatoid Arthritis Patients with Knee Synovitis: A Controlled Randomized Double-Blind Trial

    PubMed Central

    dos Santos, Marla Francisca; Furtado, Rita Nely Vilar; Konai, Monique Sayuri; Castiglioni, Mario Luiz Vieira; Marchetti, Renata Rosa; Natour, Jamil

    2009-01-01

    OBJECTIVES: The aim of the present study was to investigate the effectiveness of Samarium153-particulate hydroxyapatite radiation synovectomy in rheumatoid arthritis patients with chronic knee synovitis. METHODS: Fifty-eight rheumatoid arthritis patients (60 knees) with chronic knee synovitis participated in a controlled double-blinded trial. Patients were randomized to receive either an intra-articular injection with 40 mg triamcinolone hexacetonide alone (TH group) or 40 mg triamcinolone hexacetonide combined with 15 mCi Samarium153-particulate hydroxyapatite (Sm/TH group). Blinded examination at baseline (T0) and at 1 (T1), 4 (T4), 12 (T12), 32 (T32), and 48 (T48) weeks post-intervention were performed on all patients and included a visual analog scale for joint pain and swelling as well as data on morning stiffness, flexion, extension, knee circumference, Likert scale of improvement, percentage of improvement, SF-36 generic quality of life questionnaire, Stanford Health Assessment Questionnaire (HAQ), Lequesne index, use of non-steroidal anti-inflammatory drugs or oral corticosteroids, events and adverse effects, calls to the physician, and hospital visits. RESULTS: The sample was homogeneous at baseline, and there were no withdrawals. Improvement was observed in both groups in relation to T0, but no statistically significant differences between groups were observed regarding all variables at the time points studied. The Sm/TH group exhibited more adverse effects at T1 (p<0.05), but these were mild and transitory. No severe adverse effects were reported during follow-up. CONCLUSION: Intra-articular injection of Samarium153-particulate hydroxyapatite (15 mCi) with 40 mg of triamcinolone hexacetonide is not superior to triamcinolone hexacetonide alone for the treatment of knee synovitis in patients with rheumatoid arthritis at 1 y of follow-up. PMID:20037706

  13. Our contaminated atmosphere: The danger of climate change, phases 1 and 2. [effect of atmospheric particulate matter on surface temperature and earth's radiation budget

    NASA Technical Reports Server (NTRS)

    Cimorelli, A. J.; House, F. B.

    1974-01-01

    The effects of increased concentrations of atmospheric particulate matter on average surface temperature and on the components of the earth's radiation budget are studied. An atmospheric model which couples particulate loading to surface temperature and to changes in the earth's radiation budget was used. A determination of the feasibility of using satellites to monitor the effect of increased atmospheric particulate concentrations is performed. It was found that: (1) a change in man-made particulate loading of a factor of 4 is sufficient to initiate an ice age; (2) variations in the global and hemispheric weighted averages of surface temperature, reflected radiant fluz and emitted radiant flux are nonlinear functions of particulate loading; and (3) a black satellite sphere meets the requirement of night time measurement sensitivity, but not the required day time sensitivity. A nonblack, spherical radiometer whose external optical properties are sensitive to either the reflected radiant fluz or the emitted radiant flux meets the observational sensitivity requirements.

  14. SEM-EDX analysis in the source apportionment of particulate matter on Hypogymnia physodes lichen transplants around the Cu smelter and former mining town of Karabash, South Urals, Russia.

    PubMed

    Williamson, B J; Mikhailova, I; Purvis, O W; Udachin, V

    2004-04-25

    Scanning electron microscopy with energy-dispersive X-ray analysis (SEM-EDX) of particulate matter on lichen transplant thalli (Hypogymnia physodes) was assessed as a complementary technique to wet chemical analysis for source apportionment of airborne contaminants. Transplants (2 month exposure) stationed in the Cu smelter and former mining town of Karabash were compared with those from a control site 30 km south. Particulate matter in Karabash samples (715 analyses) showed higher levels of S, Pb, Cu, Sn and Zn compared with the control (598 analyses). Complex element associations among the particles confounded detailed mineralogical identifications, and therefore a simplified particle classification scheme was devised for source apportionment. Karabash samples contained high levels of particles classified as mining-related (MRP), and these were also identified in control samples, indicating wide spatial dispersion from the smelter and highlighting the sensitivity of the method. It was noted that MRP <2.5-microm diameter were poorly represented on lichen surfaces suggesting this may limit the usefulness of Hypogymnia transplants as proxies when assessing human health impacts from airborne particulates. Analyses of the lichen thallus surface (away from surface particulates) revealed high levels of Cu, Zn, Fe and Pb associated with organics in the Karabash samples compared with the control, with a proportionate loss of K, interpreted as being due to a stress-related increase in cell membrane permeability. This type of analysis may provide a novel SEM-EDX-based method for assessing lichen vitality. The techniques developed are presented and further implications of the study are discussed.

  15. Apollo Saturn 511 effluent measurements from the Apollo 16 launch operations: An experiment

    NASA Technical Reports Server (NTRS)

    Gregory, G. L.; Hulten, W. C.; Wornom, D. E.

    1974-01-01

    An experiment was performed in conjunction with the Apollo 16 launch to define operational and instrumentational problems associated with launch-vehicle exhaust effluent monitoring. Ground and airborne sampling were performed for CO, CO2, hydrocarbons, and particulates. Sampling systems included filter pads and photometers for particulates and whole-air grab samples for gases. Launch debris was identified in the particulate samples at ground level(taken immediately after launch) and in the airborne measurements (taken 40 to 50 minutes after launch approximately 40 km downwind of the pad). Operational problems were identified and included the need for higher instrumentation mobility and the need for real-time sampling instrumentation as opposed to collection-type samples such as the whole-air grab sample.

  16. Properties of discontinuous S2-glass fiber-particulate-reinforced resin composites with two different fiber length distributions.

    PubMed

    Huang, Qiting; Garoushi, Sufyan; Lin, Zhengmei; He, Jingwei; Qin, Wei; Liu, Fang; Vallittu, Pekka Kalevi; Lassila, Lippo Veli Juhana

    2017-10-01

    To investigate the reinforcing efficiency and light curing properties of discontinuous S2-glass fiber-particulate reinforced resin composite and to examine length distribution of discontinuous S2-glass fibers after a mixing process into resin composite. Experimental S2-glass fiber-particulate reinforced resin composites were prepared by mixing 10wt% of discontinuous S2-glass fibers, which had been manually cut into two different lengths (1.5 and 3.0mm), with various weight ratios of dimethacrylate based resin matrix and silaned BaAlSiO 2 filler particulates. The resin composite made with 25wt% of UDMA/SR833s resin system and 75wt% of silaned BaAlSiO 2 filler particulates was used as control composite which had similar composition as the commonly used resin composites. Flexural strength (FS), flexural modulus (FM) and work of fracture (WOF) were measured. Fractured specimens were observed by scanning electron microscopy. Double bond conversion (DC) and fiber length distribution were also studied. Reinforcement of resin composites with discontinuous S2-glass fibers can significantly increase the FS, FM and WOF of resin composites over the control. The fibers from the mixed resin composites showed great variation in final fiber length. The mean aspect ratio of experimental composites containing 62.5wt% of particulate fillers and 10wt% of 1.5 or 3.0mm cutting S2-glass fibers was 70 and 132, respectively. No difference was found in DC between resin composites containing S2-glass fibers with two different cutting lengths. Discontinuous S2-glass fibers can effectively reinforce the particulate-filled resin composite and thus may be potential to manufacture resin composites for high-stress bearing application. Copyright © 2017. Published by Elsevier Ltd.

  17. Instrumental neutron activation analysis data for cloud-water particulate samples, Mount Bamboo, Taiwan

    USGS Publications Warehouse

    Lin, Neng-Huei; Sheu, Guey-Rong; Wetherbee, Gregory A.; Debey, Timothy M.

    2013-01-01

    Cloud water was sampled on Mount Bamboo in northern Taiwan during March 22-24, 2002. Cloud-water samples were filtered using 0.45-micron filters to remove particulate material from the water samples. Filtered particulates were analyzed by instrumental neutron activation analysis (INAA) at the U.S. Geological Survey National Reactor Facility in Denver, Colorado, in February 2012. INAA elemental composition data for the particulate materials are presented. These data complement analyses of the aqueous portion of the cloud-water samples, which were performed earlier by the Department of Atmospheric Sciences, National Central University, Taiwan. The data are intended for evaluation of atmospheric transport processes and air-pollution sources in Southeast Asia.

  18. 78 FR 19128 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Particulate Matter Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-29

    ... holidays. We recommend that you telephone Matt Rau, Environmental Engineer, at (312) 886-6524 before visiting the Region 5 office. FOR FURTHER INFORMATION CONTACT: Matt Rau, Environmental Engineer, Control..., Restrictions on Particulate Emissions from Industrial Sources, on December 13, 2011. The revised rule was...

  19. Techniques for determining partial size distribution of particulate matter: Laser diffraction versus electrical sensing zone

    USDA-ARS?s Scientific Manuscript database

    The study of health impacts, emission estimation of particulate matter (PM), and development of new control technologies require knowledge of PM characteristics. Among these PM characteristics, the particle size distribution (PSD) is perhaps the most important physical parameter governing particle b...

  20. A LOW COST CATALYTIC FILTER FOR SIMULTANEOUS VOC AND PARTICULATE REMOVAL - PHASE II

    EPA Science Inventory

    Emissions of VOC's are subject to control by the EPA both because VOC's are regarded as ozone precursors and because many specific VOC's are hazardous air pollutants (HAP's) under the Clean Air Act Amendments. A number of industries generate offgases with both fine particul...

  1. 40 CFR 52.2276 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... its limestone quarry facilities near New Braunfels, Comal County, Texas shall install fabric filters... of the fabric filters, Parker Brothers and Co., Inc., shall not emit particulate matter in excess of 0.03 grains per standard cubic foot from the exhaust stack of the fabric filter on its primary...

  2. 40 CFR 52.2276 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... its limestone quarry facilities near New Braunfels, Comal County, Texas shall install fabric filters... of the fabric filters, Parker Brothers and Co., Inc., shall not emit particulate matter in excess of 0.03 grains per standard cubic foot from the exhaust stack of the fabric filter on its primary...

  3. Particulate measurement and control devices for hot mix asphalt plants.

    DOT National Transportation Integrated Search

    1973-01-01

    The emission of particulates is the main form of air pollution from hot mix asphalt plants. The measurement of these emissions in the ambient air may be used by the state and the plant personnel to monitor the quality of air in the area of a plant. S...

  4. 40 CFR 52.2276 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... its limestone quarry facilities near New Braunfels, Comal County, Texas shall install fabric filters... of the fabric filters, Parker Brothers and Co., Inc., shall not emit particulate matter in excess of 0.03 grains per standard cubic foot from the exhaust stack of the fabric filter on its primary...

  5. EFFECT OF AIR-POLLUTION CONTROL ON DEATH RATES IN DUBLIN, IRELAND: AN INTERVENTION STUDY. (R827353C006)

    EPA Science Inventory

    Background Particulate air pollution episodes have been associated with increased daily death. However, there is little direct evidence that diminished particulate air pollution concentrations would lead to reductions in death rates. We assessed the effect of ...

  6. CHARACTERIZATION OF PARTICULATE EMISSIONS FROM CONTROLLED CONSTRUCTION ACTIVITIES: MUD/DIRT CARRYOUT

    EPA Science Inventory

    The report describes a field study of PM-2.5 and PM-10 (particulate matter with aerodynamic diameter less than 2.5 and 10 micrometers, respectively) emissions from a public paved road in Overland Park, Kansas, adjacent to a 200-acre construction site which will ultimately have 4 ...

  7. Single Particulate SEM-EDX Analysis of Iron-Containing Coarse Particulate Matter in an Urban Environment: Sources and Distribution of Iron within Cleveland, Ohio

    EPA Science Inventory

    The physicochemical properties of coarse-mode, iron-containing particles, and their temporal and spatial distributions are poorly understood. Single particle analysis combining x-ray elemental mapping and computer-controlled scanning electron microscopy (CCSEM-EDX) of passively ...

  8. CHEMICAL AND PHYSICAL CHARACTERISTICS OF OUTDOOR, INDOOR, AND PERSONAL PARTICULATE AIR SAMPLES COLLECTED IN AND AROUND A RETIREMENT FACILITY

    EPA Science Inventory

    Residential, personal, indoor, and outdoor sampling of particulate matter was conducted at a retirement center in the Towson area of northern Baltimore County in 1998. Concurrent sampling was conducted at a central community site. Computer-controlled scanning electron microsco...

  9. Characterization of cotton gin particulate matter emissions – project plan

    USDA-ARS?s Scientific Manuscript database

    In 2006, EPA implemented a more stringent standard for particulate matter with an effective diameter less than 2.5 microns (PM2.5). The implementation timeline for this standard will vary by state/district regulatory agency. For example, the San Joaquin Valley Air Pollution Control District, has pro...

  10. Characterization of cotton gin particulate matter emissions - project plan

    USDA-ARS?s Scientific Manuscript database

    In 2006, EPA implemented a more stringent standard for particulate matter with an effective diameter less than 2.5 microns (PM2.5). The implementation time line for this standard will vary by state/district regulatory agency. For example, the San Joaquin Valley Air Pollution Control District has pro...

  11. 40 CFR 49.128 - Rule for limiting particulate matter emissions from wood products industry sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emissions from wood products industry sources. 49.128 Section 49.128 Protection of Environment ENVIRONMENTAL... Rule for limiting particulate matter emissions from wood products industry sources. (a) What is the... certain wood products industry sources operating within the Indian reservation to control ground-level...

  12. A COMPUTER-CONTROLLED SYSTEM FOR GENERATING UNIFORM SURFACE DEPOSITS TO STUDY THE TRANSPORT OF PARTICULATE MATTER

    EPA Science Inventory

    Improved methods for measuring and assessing microenvironmental exposure in individuals are needed. How human activities affect particulate matter in the personal cloud is poorly understood. A quality assurance tool to aid the study of particle transport mechanisms (e.g., re-en...

  13. A multi-factor designation method for mapping particulate-pollution control zones in China.

    PubMed

    Qin, Y; Xie, S D

    2011-09-01

    A multi-factor designation method for mapping particulate-pollution control zones was brought out through synthetically considering PM(10) pollution status, PM(10) anthropogenic emissions, fine particle pollution, long-range transport and economic situation. According to this method, China was divided into four different particulate-pollution control regions: PM Suspended Control Region, PM(10) Pollution Control Region, PM(2.5) Pollution Control Region and PM(10) and PM(2.5) Common Control Region, which accounted for 69.55%, 9.66%, 4.67% and 16.13% of China's territory, respectively. The PM(10) and PM(2.5) Common Control Region was mainly distributed in Bohai Region, Yangtze River Delta, Pearl River Delta, eastern of Sichuan province and Chongqing municipality, calling for immediate control of both PM(10) and PM(2.5). Cost-effective control effects can be achieved through concentrating efforts on PM(10) and PM(2.5) Common Control Region to address 60.32% of national PM(10) anthropogenic emissions. Air quality in districts belonging to PM(2.5) Pollution Control Region suggested that Chinese national ambient air quality standard for PM(10) was not strict enough. The result derived from application to China proved that this approach was feasible for mapping pollution control regions for a country with vast territory, complicated pollution characteristics and limited available monitoring data. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Efficiency of Emission Control Measures on Particulate Matter-Related Health Impacts and Economic Cost during the 2014 Asia-Pacific Economic Cooperation Meeting in Beijing.

    PubMed

    Liu, Qichen; Huang, Jing; Guo, Bin; Guo, Xinbiao

    2016-12-28

    Background : The Asia-Pacific Economic Cooperation (APEC) meeting was held from 5 November to 11 November 2014 in Beijing, and comprehensive emission control measures were implemented. The efficiency of these measures on particulate matter-related health impacts and economic cost need to be evaluated. Methods : The influences of emission control measures during APEC on particulate matter were evaluated, and health economic effects were assessed. Results : Average concentrations of PM 2.5 and PM 10 during APEC were reduced by 57.0%, and 50.6% respectively, compared with pre-APEC period. However, the concentrations of particulate matter rebounded after APEC. Compared with the pre-APEC and post-APEC periods, the estimated number of deaths caused by non-accidental, cardiovascular and respiratory diseases that could be attributed to PM 2.5 and PM 10 during the APEC were the lowest. The economic cost associated with mortality caused by PM 2.5 and PM 10 during the APEC were reduced by (61.3% and 66.6%) and (50.3% and 60.8%) respectively, compared with pre-APEC and post-APEC. Conclusions : The emission control measures were effective in improving short term air quality and reducing health risks and medical expenses during 2014 APEC, but more efforts is needed for long term and continuous air quality improvement and health protection.

  15. Efficiency of Emission Control Measures on Particulate Matter-Related Health Impacts and Economic Cost during the 2014 Asia-Pacific Economic Cooperation Meeting in Beijing

    PubMed Central

    Liu, Qichen; Huang, Jing; Guo, Bin; Guo, Xinbiao

    2016-01-01

    Background: The Asia-Pacific Economic Cooperation (APEC) meeting was held from 5 November to 11 November 2014 in Beijing, and comprehensive emission control measures were implemented. The efficiency of these measures on particulate matter-related health impacts and economic cost need to be evaluated. Methods: The influences of emission control measures during APEC on particulate matter were evaluated, and health economic effects were assessed. Results: Average concentrations of PM2.5 and PM10 during APEC were reduced by 57.0%, and 50.6% respectively, compared with pre-APEC period. However, the concentrations of particulate matter rebounded after APEC. Compared with the pre-APEC and post-APEC periods, the estimated number of deaths caused by non-accidental, cardiovascular and respiratory diseases that could be attributed to PM2.5 and PM10 during the APEC were the lowest. The economic cost associated with mortality caused by PM2.5 and PM10 during the APEC were reduced by (61.3% and 66.6%) and (50.3% and 60.8%) respectively, compared with pre-APEC and post-APEC. Conclusions: The emission control measures were effective in improving short term air quality and reducing health risks and medical expenses during 2014 APEC, but more efforts is needed for long term and continuous air quality improvement and health protection. PMID:28036006

  16. Size-selective sampling performance of six low-volume “total” suspended particulate (TSP) inlets

    EPA Science Inventory

    Several low-volume inlets (flow rates ≤ 16.7 liters per minute (Lpm)) are commercially available as components of low-cost, portable ambient particulate matter samplers. Because the inlets themselves do not contain internal fractionators, they are often assumed to representati...

  17. THE RESEARCH TRIANGLE PARK PARTICULATE MATTER PANEL STUDY: PM MASS CONCENTRATION RELATIONSHIPS

    EPA Science Inventory

    The U.S. Environmental Protection Agency has recently performed the Research Triangle Park Particulate Matter Panel Study. This was a one-year investigation of PM and related co-pollutants involving participants living within the RTP area of North Carolina. Primary goals were t...

  18. DESIGN AND PERFORMANCE OF A LOW FLOW RATE INLET

    EPA Science Inventory

    Several ambient air samplers that have been designated by the U. S. EPA as Federal Reference Methods (FRMs) for measuring particulate matter nominally less than 10 um (PM10) include the use of a particular inlet design that aspirates particulate matter from the atmosphere at 1...

  19. Pulse energization; A precipitator performance upgrade technology following low sulfur coal switching

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, K.S.; Feldman, P.L.; Jacobus, P.L.

    1992-01-01

    Madison Gas and Electric operates two 50 MWe pulverized coal fired boilers at its Blount station. This paper reports that these two units have been designed to operate with gas or coalfiring in combination with refuse derived fuel. Both these units are fitted with electrostatic precipitators for particulate control. Historically, these units have utilized Midwestern and Appalachian coals varying in sulfur contents between 2 and 5 %, with the SO{sub 2} emission level in the 3.5 pounds per million Btu range. Wisconsin's acid rain control law goes into effect in 1993 requiring utilities to control sulfur dioxide emissions below 1.2more » pounds per million Btu.« less

  20. [Distribution characteristics of particulate mercury in aerosol in coastal city].

    PubMed

    Zhang, Fu-Wang; Zhao, Jin-Ping; Chen, Jin-Sheng; Xu, Ya

    2010-10-01

    Particulate mercury, which is bound with aerosol in atmosphere, has a negative impact on human health and the environment, also plays an important role in the biogeochemical process of mercury. In this paper, taking southeast coastal city of Xiamen as research object, the PM2.5, PM10 and TSP were collected in residential, tourism, industrial area and background, respectively, during four seasons (October 2008-September 2009). RA-915 + mercury analyzer was employed to determinate mercury concentration in different size particle matters based on zeeman atomic absorption spectrometry. The results showed that the contents of particulate mercury in different size of aerosol during Winter, Spring were obviously higher than that of Summer, Autumn; the concentrations of particulate mercury in fine particle during Spring, Summer, Autumn and Winter were (51.46 +/- 19.28), (42.41 +/- 12.74), (38.38 +/- 6.08) and (127.23 +/- 33.70) pg/m3, respectively. The experimental data showed that the particulate mercury were mainly distributed in fine particles (PM2.5), which covered 42.48%-67.87%, and it can be concluded that the rate of particulate mercury enrichment in coarse particle was much lower than that of fine particle. The sequence of atmospheric particulate mercury concentration in different functional areas was: background < resident < tourism < industrial area < suburban; which showed characteristics of spatial distribution of particulate mercury was affected by the sampling location. On the whole, Xiamen had a low level of atmospheric particulate mercury; the enrichment of PM2.5 to particulate mercury was significantly higher than that of PM10 and TSP, and showed that fine particle pollution should be tightly controlled to reduce particulate mercury.

  1. Forms of trace arsenic, cesium, cadmium, and lead transported into river water for the irrigation of Japanese paddy rice fields

    NASA Astrophysics Data System (ADS)

    Nakaya, Shinji; Chi, Hai; Muroda, Kengo; Masuda, Harue

    2018-06-01

    In this study, we focus on the behavior of geogenic, toxic trace elements, particularly As, Cs, Cd, and Pb, during their transportation in two rivers for irrigation commonly used in monsoon Asia; one river originates from an active volcano, Mt. Asama, and the other originates from a currently inactive volcano, Yatsugatake Mountains in Nagano, Japan. These rivers were investigated to understand the role of river water as a pollutant of rice and other aquatic plants (via irrigation) and aquatic animals. The results indicated that the behavior of toxic trace elements in river water are likely controlled by their interactions with particulate Fe, Al, and Ti compounds. The majority of Pb and Cd is transported as particulate matter with Fe, Al, and Ti, while the majority of As is transported in the dissolved form, predominantly as arsenate, with low abundance of particulate matter. Cs is transported either as the dissolved form or as particulate matter in both rivers. The investigated elements are transported in the rivers as particulate and dissolved forms, and the ratio of these forms is controlled by the pH and presence of particulate Fe, Al, and Ti phases in the river water. With respect to Cs in both rivers, the parameter governing the concentration and transportation of Cs, in the bimodal form (i.e., particulate and dissolved forms), through the river possibly shifts from sorption to pH by particulate Fe-Al-Ti, according to the abrupt increase in the concentration of Cs in the river. The chemical attraction of particulate Fe-Al-Ti for Cs is weaker than that for Pb and Cd, indicating that the lower electronegativity of Cs weakens the chemical attraction on a colloid for the competitive sorption with the other trace elements. The different relationships between As and Fe in the river and in the irrigation water and soil water, as well as those in paddy rice, suggested that As in paddy rice is not directly derived from As in the irrigation water from the river under flooding.

  2. Adsorbents for capturing mercury in coal-fired boiler flue gas.

    PubMed

    Yang, Hongqun; Xu, Zhenghe; Fan, Maohong; Bland, Alan E; Judkins, Roddie R

    2007-07-19

    This paper reviews recent advances in the research and development of sorbents used to capture mercury from coal-fired utility boiler flue gas. Mercury emissions are the source of serious health concerns. Worldwide mercury emissions from human activities are estimated to be 1000 to 6000 t/annum. Mercury emissions from coal-fired power plants are believed to be the largest source of anthropogenic mercury emissions. Mercury emissions from coal-fired utility boilers vary in total amount and speciation, depending on coal types, boiler operating conditions, and configurations of air pollution control devices (APCDs). The APCDs, such as fabric filter (FF) bag house, electrostatic precipitator (ESP), and wet flue gas desulfurization (FGD), can remove some particulate-bound and oxidized forms of mercury. Elemental mercury often escapes from these devices. Activated carbon injection upstream of a particulate control device has been shown to have the best potential to remove both elemental and oxidized mercury from the flue gas. For this paper, NORIT FGD activated carbon was extensively studied for its mercury adsorption behavior. Results from bench-, pilot- and field-scale studies, mercury adsorption by coal chars, and a case of lignite-burned mercury control were reviewed. Studies of brominated carbon, sulfur-impregnated carbon and chloride-impregnated carbon were also reviewed. Carbon substitutes, such as calcium sorbents, petroleum coke, zeolites and fly ash were analyzed for their mercury-adsorption performance. At this time, brominated activated carbon appears to be the best-performing mercury sorbent. A non-injection regenerable sorbent technology is briefly introduced herein, and the issue of mercury leachability is briefly covered. Future research directions are suggested.

  3. APTI Course 450, Source Sampling for Particulate Pollutants. Instructor's Guide.

    ERIC Educational Resources Information Center

    Aldina, G. J.; And Others

    This manual covers a four and one half day laboratory course in source sampling for particulates. The course presents principles and techniques necessary for performing isokinetic source sampling procedures. Lectures cover formulas dealing with basic fluid mechanics appropriate to the techniques employed. Laboratory exercises are intended to…

  4. GUIDANCE FOR THE PERFORMANCE EVALUATION OF THREE-DIMENSIONAL AIR QUALITY MODELING SYSTEMS FOR PARTICULATE MATTER AND VISIBILITY

    EPA Science Inventory

    The National Ambient Air Quality Standards for particulate matter (PM) and the federal regional haze regulations place some emphasis on the assessment of fine particle (PM; 5) concentrations. Current air quality models need to be improved and evaluated against observations to a...

  5. Thermoelectric performance of SrTiO3 enhanced by nanostructuring-self-assembled particulate film of nanocubes.

    PubMed

    Dang, Feng; Wan, Chunlei; Park, Nam-Hee; Tsuruta, Kazuki; Seo, Won-Seon; Koumoto, Kunihito

    2013-11-13

    Self-assembled particulate films with a uniform structure over a large area were prepared from La-SrTiO3 nanocubes for thermoelectric applications. UV irradiation was used to assist the formation of particulate film for decomposition of the organic phase in situ to obtain a mechanically robust structure at high temperature. The thermoelectric properties of the particulate film were measured after calcination at 1000 °C under a reductive atmosphere (Ar/H2 = 60/40). A Seebeck coefficient of S = -239 ± 24 μV/K, electrical conductivity of σ = 160 ± 5 S/cm, and thermal conductivity of κ ≈ 1.5 W/mK were obtained for a self-assembled particulate film (La: 5%) corresponding to a ZT value of 0.2 at room temperature, which exceeded that of a La-SrTiO3 single crystal with similar composition.

  6. A prospective, randomized controlled preclinical trial to evaluate different formulations of biphasic calcium phosphate in combination with a hydroxyapatite collagen membrane to reconstruct deficient alveolar ridges.

    PubMed

    Nevins, Myron; Nevins, Marc L; Schupbach, Peter; Kim, Soo-Woo; Lin, Zhao; Kim, David M

    2013-04-01

    Many patients and clinicians would prefer a synthetic particulate bone replacement graft, but most available alloplastic biomaterials have limited osteogenic potential. An alloplast with increased regenerative capacity would be advantageous for the treatment of localized alveolar ridge defects. This prospective, randomized controlled preclinical trial utilized 6 female foxhounds to analyze the osteogenic impact of different formulations of biphasic calcium phosphate (BCP) in combination with an hydroxyapatite-collagen membrane and their ability to reconstruct deficient alveolar ridges for future implant placement. The grafted sites were allowed to heal 3 months, and then trephine biopsies were obtained to perform light microscopic and histomorphometric analyses. All treated sites healed well with no early membrane exposure or adverse soft tissue responses during the healing period. The grafted sites exhibited greater radiopacity than the surrounding native bone with BCP particles seen as radiopaque granules. The graft particles appeared to be well-integrated and no areas of loose particles were observed. Histologic evaluation demonstrated BCP particles embedded in woven bone with dense connective tissue/marrow space. New bone growth was observed around the graft particles as well as within the structure of the graft particulate. There was intimate contact between the graft particles and newly formed bone, and graft particles were bridged by the newly formed bone in all biopsies from the tested groups. The present study results support the potential of these BCP graft particulates to stimulate new bone formation. Clinical studies are recommended to confirm these preclinical findings.

  7. Characteristics of inhalable particulate matter concentration and size distribution from power plants in China.

    PubMed

    Yi, Honghong; Hao, Jiming; Duan, Lei; Li, Xinghua; Guo, Xingming

    2006-09-01

    In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 microm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38-99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1-1 microm. In this size range, ESP and baghouse collection efficiencies are 85.79-98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.

  8. Impacts of continuously regenerating trap and particle oxidation catalyst on the NO2 and particulate matter emissions emitted from diesel engine.

    PubMed

    Liu, Zhihua; Ge, Yunshan; Tan, Jianwei; He, Chao; Shah, Asad Naeem; Ding, Yan; Yu, Linxiao; Zhao, Wei

    2012-01-01

    Two continuously regenerating diesel particulate filter (CRDPF) with different configurations and one particles oxidation catalyst (POC) were employed to perform experiments in a controlled laboratory setting to evaluate their effects on NO2, smoke and particle number emissions. The results showed that the application of the after-treatments increased the emission ratios of NO2/NOx significantly. The results of smoke emissions and particle number (PN) emissions indicated that both CRDPFs had sufficient capacity to remove more than 90% of total particulate matter (PM) and more than 97% of solid particles. However, the POC was able to remove the organic components of total PM, and only partially to remove the carbonaceous particles with size less than 30 nm. The negligible effects of POC on larger particles were observed due to its honeycomb structure leads to an inadequate residence time to oxidize the solid particles or trap them. The particles removal efficiencies of CRDPFs had high degree of correlations with the emission ratio of NO2/NOx. The PN emission results from two CRDPFs indicated that more NO2 generating in diesel oxidation catalyst section could obtain the higher removal efficiency of solid particles. However this also increased the risk of NO2 exposure in atmosphere.

  9. Emissions of volatile organic compounds and particulate matter from small-scale peat fires

    NASA Astrophysics Data System (ADS)

    George, I. J.; Black, R.; Walker, J. T.; Hays, M. D.; Tabor, D.; Gullett, B.

    2013-12-01

    Air pollution emitted from peat fires can negatively impact regional air quality, visibility, climate, and human health. Peat fires can smolder over long periods of time and, therefore, can release significantly greater amounts of carbon into the atmosphere per unit area compared to burning of other types of biomass. However, few studies have characterized the gas and particulate emissions from peat burning. To assess the atmospheric impact of peat fires, particulate matter (PM) and volatile organic compounds (VOCs) were quantified from controlled small-scale peat fire experiments. Major carbon emissions (i.e. CO2, CO, methane and total hydrocarbons) were measured during the peat burn experiments. Speciated PM mass was also determined from the peat burns from filter and polyurethane foam samples. Whole air samples were taken in SUMMA canisters and analyzed by gas chromatography-mass spectrometry to measure 82 trace VOCs. Additional gaseous carbonyl species were measured by sampling with dinitrophenylhydrazine-coated cartridges and analyzed with high performance liquid chromatography. VOCs with highest observed concentrations measured from the peat burns were propylene, benzene, chloromethane and toluene. Gas-phase carbonyls with highest observed concentrations included acetaldehyde, formaldehyde and acetone. Emission factors of major pollutants will be compared with recommended values for peat and other biomass burning.

  10. Techno-economic analysis of wood biomass boilers for the greenhouse industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chau, J.; Sowlati, T.; Sokhansanj, Shahabaddine

    2009-01-01

    The objective of this study is to perform a techno-economic analysis on a typical wood pellet and wood residue boiler for generation of heat to an average-sized greenhouse in British Columbia. The variables analyzed included greenhouse size and structure, boiler efficiency, fuel types, and source of carbon dioxide (CO2) for crop fertilization. The net present value (NPV) show that installing a wood pellet or a wood residue boiler to provide 40% of the annual heat demand is more economical than using a natural gas boiler to provide all the heat at a discount rate of 10%. For an assumed lifespanmore » of 25 years, a wood pellet boiler system could generate NPV of C$259,311 without electrostatic precipitator (ESP) and C$74,695 with ESP, respectively. While, installing a wood residue boiler with or without an ESP could provide NPV of C$919,922 or C$1,104,538, respectively. Using a wood biomass boiler could also eliminate over 3000 tonne CO2 equivalents of greenhouse gases annually. Wood biomass combustion generates more particulate matters than natural gas combustion. However, an advanced emission control system could significantly reduce particulate matters emission from wood biomass combustion which would bring the particulate emission to a relatively similar level as for natural gas.« less

  11. Carcinogenicity of airborne fine particulate benzo(a)pyrene: an appraisal of the evidence and the need for control.

    PubMed Central

    Perera, F

    1981-01-01

    Benzo(a)pyrene(BaP) originating from fossil fuel and other organic combustion processes is largely adsorbed on fine particulate and hence is a widespread atmospheric pollutant. Available emissions and air quality data are based on the total weight of particulate matter without reference to size and give little information on trends and concentrations of fine particulate BaP. Greater reliance on coal, synfuels and diesel fuel for energy production and transportation will significantly increase ambient levels of BaP. Because of the particulate size, BaP is substantially deposited in the lower lung and readily eluted into surrounding tissue. After elution in the lung, BaP is metabolically activated to its electrophilic, carcinogenic from by a complex enzyme system whose activity is increased by prior exposure to air pollutants, cigarette smoke and certain drugs. The resultant diol epoxide metabolite has been shown to bind covalently with the DNA of the lung. In experimental animals, BaP is a potent initiating carcinogen whose action is enhanced by sulfur dioxide, promoting agents and carrier fine particles. The effect of small, divided doses of BaP has been shown to be greater than that of a single high dose; no threshold has been established. Epidemiological studies show that mixtures containing BaP (such as urban air, industrial emissions and cigarette smoke) are carcinogenic and may interact synergistically. Occupational studies indicate that the action of BaP-containing mixtures is enhanced in the presence of SO2. However, quantitative risk assessment for BaP is precluded by problems in extrapolating to the general population from small-scale animal studies; uncertainties in findings of epidemiology; and imprecise exposure data. Existing stationary and mobile controls preferentially remove coarse particulate matter and are inefficient collectors of the particulate BaP. In the current absence of health and environmental standards for BaP, there is little incentive to control BaP emissions. BaP meets the criteria for regulation under the Clean Air Act; however, no such BaP standards have yet been proposed. PMID:6277615

  12. Development of a clean optical telescope

    NASA Technical Reports Server (NTRS)

    Brown, R. A.

    1983-01-01

    Particulate contamination on astronomical mirrors degrades performance in two ways: by information loss by extinction of light; and background and noise from scattering, especially forward or Fraunhofer scattering. These effects were not generally understood, and an ambitious pilot program was outlined to measure particulate effects on telescope optical performance; develop prophylactic and cleaning procedures suitable for groundbased observatories; investigate by computational modelling the effects on telescopes in space; and communicate the results and concerns within the astronomical community.

  13. Tuberculosis Infection Control in Health-Care Facilities: Environmental Control and Personal Protection.

    PubMed

    Lee, Ji Yeon

    2016-10-01

    Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installation of ventilation systems is a priority because ventilation reduces the number of infectious particles in the air. Natural ventilation is cost-effective but depends on climatic conditions. Supplemented intervention such as air-cleaning methods including high efficiency particulate air filtration and ultraviolet germicidal irradiation should be considered in areas where adequate ventilation is difficult to achieve. Personal protective equipment including particulate respirators provides additional benefit when administrative and environmental controls cannot assure protection.

  14. Wearing long sleeves while prepping a patient in the operating room decreases airborne contaminants.

    PubMed

    Markel, Troy A; Gormley, Thomas; Greeley, Damon; Ostojic, John; Wagner, Jennifer

    2018-04-01

    The use of long sleeves by nonscrubbed personnel in the operating room has been called into question. We hypothesized that wearing long sleeves and gloves, compared with having bare arms without gloves, while applying the skin preparation solution would decrease particulate and microbial contamination. A mock patient skin prep was performed in 3 different operating rooms. A long-sleeved gown and gloves, or bare arms, were used to perform the procedure. Particle counters were used to assess airborne particulate contamination, and active and passive microbial assessment was achieved through air samplers and settle plate analysis. Data were compared with Student's t-test or Mann-Whitney U, and P < .05 was considered to be significant. Operating room B demonstrated decreased 5.0- µm particle sizes with the use of sleeves, while operating rooms A and C showed decreased total microbes only with the use of sleeves. Despite there being no difference in the average number of total microbes for all operating rooms assessed, the use of sleeves specifically appeared to decrease the shed of Micrococcus. The use of long sleeves and gloves while applying the skin preparation solution decreased particulate and microbial shedding in several of the operating rooms tested. Although long sleeves may not be necessary for all operating room personnel, they may decrease airborne contamination while the skin prep is applied, which may lead to decreased surgical site infections. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Characterization of Dust on Solar Devices in Southern Nevada =

    NASA Astrophysics Data System (ADS)

    Sylva, Jason R.

    Dust can impact the efficiency of solar energy collection devices, and in some arid environments, dust can reduce solar energy efficiency up to 30%. Reducing the impact of dust is therefore critical in the expansion of solar technology throughout regions where solar energy is utilized. Characterization of suspended and settled particulate matter can assist in developing strategies for dust mitigation. With the characterization of suspended and settled particulate in remote, rural, and urban environments, more informed decisions can be made regarding the selection of coating material on solar panels as well as developing cleaning and maintenance procedures. Particulate matter that deposits on a solar surface can potentially interact with solar radiation, precipitation, or even directly with the surface material itself. These interactions could lead to the formation of coatings that reduce/block radiation and/or degrade the integrity of the surface. When you extrapolate these possibilities to a larger scale preliminary characterization of dust will play a vital role when planning the construction of a solar energy facility. A variety of sampling techniques were employed to obtain particulate matter for characterization. These included direct collection of particulates from solar surfaces: via vacuum and wipe sample collection on panels, tacky dot adhesive slides and plain slides that were exposed at different intervals, desert vugs that are natural particulate collectors, as well as high volume air sampling for collection of suspended particulates. High volume air sampling was performed using glass fiber filters and 2 micron stainless steel screens. Direct collection of settled particulates was performed by sampling from solar surfaces, vugs, and by collection on exposed glass surfaces. Collection onto glass surfaces was achieved by setting up a plain microscope slide, tacky dot slides, and panes of glass. The sampling methodology allowed for the collection of samples for analyses using various analytical methods that included Raman microspectroscopy, pyrolysis gas chromatography mass spectrometry, ion chromatography and inductively coupled plasma mass spectrometry. These various methods allow for identification of organic and inorganic components as well the mineral distribution of suspended and settled particulate material. None None None None None

  16. Combustor for fine particulate coal

    DOEpatents

    Carlson, L.W.

    1988-01-26

    A particulate coal combustor with two combustion chambers is provided. The first combustion chamber is toroidal; air and fuel are injected, mixed, circulated and partially combusted. The air to fuel ratio is controlled to avoid production of soot or nitrogen oxides. The mixture is then moved to a second combustion chamber by injection of additional air where combustion is completed and ash removed. Temperature in the second chamber is controlled by cooling and gas mixing. The clean stream of hot gas is then delivered to a prime mover. 4 figs.

  17. Combustor for fine particulate coal

    DOEpatents

    Carlson, Larry W.

    1988-01-01

    A particulate coal combustor with two combustion chambers is provided. The first combustion chamber is toroidal; air and fuel are injected, mixed, circulated and partially combusted. The air to fuel ratio is controlled to avoid production of soot or nitrogen oxides. The mixture is then moved to a second combustion chamber by injection of additional air where combustion is completed and ash removed. Temperature in the second chamber is controlled by cooling and gas mixing. The clean stream of hot gas is then delivered to a prime mover.

  18. Combustor for fine particulate coal

    DOEpatents

    Carlson, L.W.

    1988-11-08

    A particulate coal combustor with two combustion chambers is provided. The first combustion chamber is toroidal; air and fuel are injected, mixed, circulated and partially combusted. The air to fuel ratio is controlled to avoid production of soot or nitrogen oxides. The mixture is then moved to a second combustion chamber by injection of additional air where combustion is completed and ash removed. Temperature in the second chamber is controlled by cooling and gas mixing. The clean stream of hot gas is then delivered to a prime mover. 4 figs.

  19. 40 CFR 49.128 - Rule for limiting particulate matter emissions from wood products industry sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emissions from wood products industry sources. 49.128 Section 49.128 Protection of Environment ENVIRONMENTAL... Region 10 § 49.128 Rule for limiting particulate matter emissions from wood products industry sources. (a... emitted from certain wood products industry sources operating within the Indian reservation to control...

  20. 40 CFR 49.128 - Rule for limiting particulate matter emissions from wood products industry sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emissions from wood products industry sources. 49.128 Section 49.128 Protection of Environment ENVIRONMENTAL... Region 10 § 49.128 Rule for limiting particulate matter emissions from wood products industry sources. (a... emitted from certain wood products industry sources operating within the Indian reservation to control...

  1. ARE CARS OR TREES MORE IMPORTANT TO PARTICULATE MATTER AIR POLUTION? WHAT RADIOCARBON MEASUREMENTS HAVE TO SAY

    EPA Science Inventory

    Air pollution in the form of particulate matter (PM) originates from both human activities and "natural" phenomena. Setting and achieving National Ambient Air Quality Standards (NAAQS) for PM has to take into account the latter since they are in general less controllable than th...

  2. 78 FR 882 - Approval and Promulgation of Air Quality Implementation Plans; Delaware, New Jersey, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-07

    ...)(2).) List of Subjects in 40 CFR Part 52 Environmental protection, Air pollution control... 2011 ambient air quality data, the Philadelphia-Wilmington, PA-NJ-DE fine particulate matter (PM 2.5... 2011 ambient air quality data, the Philadelphia-Wilmington, PA-NJ-DE fine particulate matter (PM 2.5...

  3. 40 CFR 266.105 - Standards to control particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standard cubic foot) after correction to a stack gas concentration of 7% oxygen, using procedures... particulate matter standard. (c) Oxygen correction. (1) Measured pollutant levels must be corrected for the amount of oxygen in the stack gas according to the formula: ER30SE99.027 Where: Pc is the corrected...

  4. 40 CFR 266.105 - Standards to control particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... standard cubic foot) after correction to a stack gas concentration of 7% oxygen, using procedures... particulate matter standard. (c) Oxygen correction. (1) Measured pollutant levels must be corrected for the amount of oxygen in the stack gas according to the formula: ER30SE99.027 Where: Pc is the corrected...

  5. 40 CFR 266.105 - Standards to control particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... standard cubic foot) after correction to a stack gas concentration of 7% oxygen, using procedures... particulate matter standard. (c) Oxygen correction. (1) Measured pollutant levels must be corrected for the amount of oxygen in the stack gas according to the formula: ER30SE99.027 Where: Pc is the corrected...

  6. 40 CFR 266.105 - Standards to control particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... standard cubic foot) after correction to a stack gas concentration of 7% oxygen, using procedures... particulate matter standard. (c) Oxygen correction. (1) Measured pollutant levels must be corrected for the amount of oxygen in the stack gas according to the formula: ER30SE99.027 Where: Pc is the corrected...

  7. 40 CFR 49.128 - Rule for limiting particulate matter emissions from wood products industry sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emissions from wood products industry sources. 49.128 Section 49.128 Protection of Environment ENVIRONMENTAL... Region 10 § 49.128 Rule for limiting particulate matter emissions from wood products industry sources. (a... emitted from certain wood products industry sources operating within the Indian reservation to control...

  8. KENNEDY SPACE CENTER, FLA. - A KSC employee uses a clean-air shower before entering a clean room. Streams of pressurized air directed at the occupant from nozzles in the chamber's ceiling and walls are designed to dislodge particulate matter from hair, clothing and shoes. The adhesive mat on the floor captures soil from shoe soles, as well as particles that fall on its surface. Particulate matter has the potential to contaminate the space flight hardware being stored or processed in the clean room. The shower is part of KSC's Foreign Object Debris (FOD) control program, an important safety initiative.

    NASA Image and Video Library

    2003-08-29

    KENNEDY SPACE CENTER, FLA. - A KSC employee uses a clean-air shower before entering a clean room. Streams of pressurized air directed at the occupant from nozzles in the chamber's ceiling and walls are designed to dislodge particulate matter from hair, clothing and shoes. The adhesive mat on the floor captures soil from shoe soles, as well as particles that fall on its surface. Particulate matter has the potential to contaminate the space flight hardware being stored or processed in the clean room. The shower is part of KSC's Foreign Object Debris (FOD) control program, an important safety initiative.

  9. Toxicity and mutagenicity of exhaust from compressed natural gas: Could this be a clean solution for megacities with mixed-traffic conditions?

    PubMed

    Agarwal, Avinash K; Ateeq, Bushra; Gupta, Tarun; Singh, Akhilendra P; Pandey, Swaroop K; Sharma, Nikhil; Agarwal, Rashmi A; Gupta, Neeraj K; Sharma, Hemant; Jain, Ayush; Shukla, Pravesh C

    2018-08-01

    Despite intensive research carried out on particulates, correlation between engine-out particulate emissions and adverse health effects is not well understood yet. Particulate emissions hold enormous significance for mega-cities like Delhi that have immense traffic diversity. Entire public transportation system involving taxis, three-wheelers, and buses has been switched from conventional liquid fuels to compressed natural gas (CNG) in the Mega-city of Delhi. In this study, the particulate characterization was carried out on variety of engines including three diesel engines complying with Euro-II, Euro-III and Euro-IV emission norms, one Euro-II gasoline engine and one Euro-IV CNG engine. Physical, chemical and biological characterizations of particulates were performed to assess the particulate toxicity. The mutagenic potential of particulate samples was investigated at different concentrations using two different Salmonella strains, TA98 and TA100 in presence and absence of liver S9 metabolic enzyme fraction. Particulates emitted from diesel and gasoline engines showed higher mutagenicity, while those from CNG engine showed negligible mutagenicity compared to other test fuels and engine configurations. Polycyclic aromatic hydrocarbons (PAHs) adsorbed onto CNG engine particulates were also relatively fewer compared to those from equivalent diesel and gasoline engines. Taken together, our findings indicate that CNG is comparatively safer fuel compared to diesel and gasoline and can offer a cleaner transport energy solution for mega-cities with mixed-traffic conditions, especially in developing countries. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sappok, Alex; Ragaller, Paul; Herman, Andrew

    The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this study, radio frequency (RF) sensors were used to directlymore » monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.« less

  11. The Effect of Oyster Reef Morphology on Particulate Transfer in a North Carolina Tidal Creek

    NASA Astrophysics Data System (ADS)

    Lemon, M. G.; Posey, M.; Mallin, M.; Alphin, T.

    2014-12-01

    The eastern oyster (Crassostrea virginica) is a vital ecosystem engineer species, providing a number of ecosystem services that structure and maintain estuarine environments through the construction of large, hard-bottom reef complexes. Through suspension feeding, oysters clear the water column of particulates, leading to decreased suspended material and enhanced benthic pelagic coupling. Past field studies have indicated the potential importance of the physical reef structure in regulating the transfer of particulate material in the seston. In order to directly assess the existence of the physical reef effect, multiple field experiments were performed in a small tidal creek estuary along the south eastern coast of North Carolina. Comparison of clearance rates derived from two different in situ methods, one accounting for the physical structure of the oyster reef in addition to oyster filtration and one looking at oyster filtration alone, indicate that the reef structure may increase the amount of particulate removal performed by the reef by more than 4 times the removal performed by oyster filtration alone. A defaunation experiment was performed by eliminating the live component of the oyster reef and comparing particulate transfer of this defaunated transect to that of an adjacent faunated transect. The defaunated transect had reduced but not significantly lower material removal when compared to the faunated transect prior to defaunation. Results from short and long term sediment collection and flow velocity measurements indicate that the physical effect of oyster reefs is strong over short temporal scales (days) but is much smaller when evaluated over longer time periods (months). Generally, large silt and small sand sized material is permanently removed from the seston due to the interaction of oyster reef structure and tidal flows, however the transfer of small and medium sized silt grains is only slowed down by the presence of large reef complexes. This effect has important ecological implications for downstream water quality and must be accounted for when modeling water quality improvements performed by oysters.

  12. Control strategies for the reduction of airborne particulate nitrate in California's San Joaquin Valley

    NASA Astrophysics Data System (ADS)

    Kleeman, Michael J.; Ying, Qi; Kaduwela, Ajith

    The effect of NO x, volatile organic compound (VOC), and NH 3 emissions control programs on the formation of particulate ammonium nitrate in the San Joaquin Valley (SJV) was examined under the typical winter conditions that existed on 4-6 January, 1996. The UCD/CIT photochemical transport model was used for this study so that the source origin of primary particulate matter and secondary particulate matter could be identified. When averaged across the entire SJV, the model results predict that 13-18% of the reactive nitrogen (NO y=NO x+reaction products of NO x) emitted from local sources within the SJV was converted to nitrate at the ground level. Each gram of NO x emitted locally within the SJV (expressed as NO 2) produced 0.23-0.31 g of particulate ammonium nitrate (NH 4NO 3), which is much smaller than the maximum theoretical yield of 1.7 g of NH 4NO 3 per gram of NO 2. The fraction of reactive nitrogen converted to nitrate varied strongly as a function of location. Urban regions with large amounts of fresh NO emissions converted little reactive nitrogen to nitrate, while remote areas had up to 70% conversion (equivalent to approximately 1.2 g of NH 4NO 3 per gram of NO 2). The use of a single spatially averaged ratio of NH 4NO 3/NO x as a predictor of how changes to NO x emissions would affect particulate nitrate concentrations would not be accurate at all locations in the SJV under the conditions studied. The largest local sources of particulate nitrate in the SJV were predicted to be diesel engines and catalyst equipped gasoline engines under the conditions experienced on 6 January, 1996. Together, these sources accounted for less than half of the ground-level nitrate aerosol in the SJV. The remaining fraction of the aerosol nitrate originated from reactive nitrogen originally released upwind of the SJV. The majority of this upwind reactive nitrogen was already transformed to nitrate by the time it entered the SJV. The effect of local emissions controls on this upwind material was small. A 50% reduction in NO x emissions applied to sources within the SJV reduced the predicted concentration of total nitrate by approximately 25% during the study episode. VOC emissions controls were less effective, while reasonable NH 3 emissions controls had the smallest effect on the amount of ammonium nitrate produced. A 50% reduction in VOC emissions lowered predicted concentrations of total nitrate by 17.5%, while a 50% reduction in NH 3 emissions lowered predicted concentrations of total nitrate by only 10%. This latter result is expected since the formation of ammonium nitrate aerosol is limited by the availability of gas-phase nitric acid, with large amounts of excess NH 3 available. NO x emissions controls appear to be the most efficient method to reduce the concentration of locally generated particulate nitrate in the SJV under the conditions experienced on 4-6 January, 1996.

  13. Composition of water and suspended sediment in streams of urbanized subtropical watersheds in Hawaii

    USGS Publications Warehouse

    De Carlo, E. H.; Beltran, V.L.; Tomlinson, M.S.

    2004-01-01

    Urbanization on the small subtropical island of Oahu, Hawaii provides an opportunity to examine how anthropogenic activity affects the composition of material transferred from land to ocean by streams. This paper investigates the variability in concentrations of trace elements (Pb, Zn, Cu, Ba, Co, As, Ni, V and Cr) in streams of watersheds on Oahu, Hawaii. The focus is on water and suspended particulate matter collected from the Ala Wai Canal watershed in Honolulu and also the Kaneohe Stream watershed. As predicted, suspended particulate matter controls most trace element transport. Elements such as Pb, Zn, Cu, Ba and Co exhibit increased concentrations within urbanized portions of the watersheds. Particulate concentrations of these elements vary temporally during storms owing to input of road runoff containing elevated concentrations of elements associated with vehicular traffic and other anthropogenic activities. Enrichments of As in samples from predominantly conservation areas are interpreted as reflecting agricultural use of fertilizers at the boundaries of urban and conservation lands. Particulate Ni, V and Cr exhibit distributions during storm events that suggest a mineralogical control. Principal component analysis of particulate trace element concentrations establishes eigenvalues that account for nearly 80% of the total variance and separates trace elements into 3 factors. Factor 1 includes Pb, Zn, Cu, Ba and Co, interpreted to represent metals with an urban anthropogenic enrichment. Factor 2 includes Ni, V and Cr, elements whose concentrations do not appear to derive from anthropogenic activity and is interpreted to reflect mineralogical control. Another, albeit less significant, anthropogenic factor includes As, Cd and U and is thought to represent agricultural inputs. Samples collected during a storm derived from an offshore low-pressure system suggest that downstream transport of upper watershed material during tradewind-derived rains results in a 2-3-fold dilution of the particulate concentrations of Pb, Zn and Cu in the Ala Wai canal watershed. ?? 2004 Elsevier Ltd. All rights reserved.

  14. Analysis of Metallized Teflon(trademark) Film Materials Performance on Satellites

    NASA Technical Reports Server (NTRS)

    Pippin, H. Gary; Normand, Eugene; Wolf, Suzanne L. B.; Kamenetzky, Rachel; Kauffman, William J., Jr. (Technical Monitor)

    2002-01-01

    Laboratory and on-orbit performance data for two common thermal control materials, silver- and aluminum-backed (metallized) fluorinated ethyl-propylene (TER) was collected from a variety of sources and analyzed. This paper demonstrates that the change in solar absorptance, alpha, is a strong function of particulate radiation for these materials. Examination of additional data shows that the atomic oxygen recession rate is a strong function of solar exposure with an induction period of between 25 to 50 equivalent solar hours. The relationships determined in this analysis were incorporated into an electronic knowledge base, the 'Spacecraft Materials Selector,' under NASA contract NAS8-98213.

  15. Rate-programming of nano-particulate delivery systems for smart bioactive scaffolds in tissue engineering.

    PubMed

    Izadifar, Mohammad; Haddadi, Azita; Chen, Xiongbiao; Kelly, Michael E

    2015-01-09

    Development of smart bioactive scaffolds is of importance in tissue engineering, where cell proliferation, differentiation and migration within scaffolds can be regulated by the interactions between cells and scaffold through the use of growth factors (GFs) and extra cellular matrix peptides. One challenge in this area is to spatiotemporally control the dose, sequence and profile of release of GFs so as to regulate cellular fates during tissue regeneration. This challenge would be addressed by rate-programming of nano-particulate delivery systems, where the release of GFs via polymeric nanoparticles is controlled by means of the methods of, such as externally-controlled and physicochemically/architecturally-modulated so as to mimic the profile of physiological GFs. Identifying and understanding such factors as the desired release profiles, mechanisms of release, physicochemical characteristics of polymeric nanoparticles, and externally-triggering stimuli are essential for designing and optimizing such delivery systems. This review surveys the recent studies on the desired release profiles of GFs in various tissue engineering applications, elucidates the major release mechanisms and critical factors affecting release profiles, and overviews the role played by the mathematical models for optimizing nano-particulate delivery systems. Potentials of stimuli responsive nanoparticles for spatiotemporal control of GF release are also presented, along with the recent advances in strategies for spatiotemporal control of GF delivery within tissue engineered scaffolds. The recommendation for the future studies to overcome challenges for developing sophisticated particulate delivery systems in tissue engineering is discussed prior to the presentation of conclusions drawn from this paper.

  16. Aqueous Cleaning and Validation for Space Shuttle Propulsion Hardware at the White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hornung, Steven D.; Biesinger, Paul; Kirsch, Mike; Beeson, Harold; Leuders, Kathy

    1999-01-01

    The NASA White Sands Test Facility (WSTF) has developed an entirely aqueous final cleaning and verification process to replace the current chlorofluorocarbon (CFC) 113 based process. This process has been accepted for final cleaning and cleanliness verification of WSTF ground support equipment. The aqueous process relies on ultrapure water at 50 C (323 K) and ultrasonic agitation for removal of organic compounds and particulate. The cleanliness is verified bv determining the total organic carbon (TOC) content and filtration with particulate counting. The effectiveness of the aqueous methods for detecting hydrocarbon contamination and particulate was compared to the accepted CFC 113 sampling procedures. Testing with known contaminants, such as hydraulic fluid and cutting and lubricating oils, to establish a correlation between aqueous TOC and CFC 113 nonvolatile residue (NVR) was performed. Particulate sampling on cleaned batches of hardware that were randomly separated and sampled by the two methods was performed. This paper presents the approach and results, and discusses the issues in establishing the equivalence of aqueous sampling to CFC 113 sampling, while describing the approach for implementing aqueous techniques on Space Shuttle Propulsion hardware.

  17. Emission factors of particulate matter, polycyclic aromatic hydrocarbons, and levoglucosan from wood combustion in south-central Chile.

    PubMed

    Jimenez, Jorge; Farias, Oscar; Quiroz, Roberto; Yañez, Jorge

    2017-07-01

    In south-central Chile, wood stoves have been identified as an important source of air pollution in populated areas. Eucalyptus (Eucalyptus globulus), Chilean oak (Nothofagus oblique), and mimosa (Acacia dealbata) were burned in a single-chamber slow-combustion wood stove at a controlled testing facility located at the University of Concepción, Chile. In each experiment, 2.7-3.1 kg of firewood were combusted while continuously monitoring temperature, exhaust gases, burn rate, and collecting particulate matter samples in Teflon filters under isokinetic conditions for polycyclic aromatic hydrocarbon and levoglucosan analyses. Mean particulate matter emission factors were 2.03, 4.06, and 3.84 g/kg dry wood for eucalyptus, oak, and mimosa, respectively. The emission factors were inversely correlated with combustion efficiency. The mean emission factors of the sums of 12 polycyclic aromatic hydrocarbons in particle phases were 1472.5, 2134.0, and 747.5 μg/kg for eucalyptus, oak, and mimosa, respectively. Fluoranthene, pyrene, benzo[a]anthracene, and chrysene were present in the particle phase in higher proportions compared with other polycyclic aromatic hydrocarbons that were analyzed. Mean levoglucosan emission factors were 854.9, 202.3, and 328.0 mg/kg for eucalyptus, oak, and mimosa, respectively. Since the emissions of particulate matter and other pollutants were inversely correlated with combustion efficiency, implementing more efficient technologies would help to reduce air pollutant emissions from wood combustion. Residential wood burning has been identified as a significant source of air pollution in populated areas. Local wood species are combusted for home cooking and heating, which releases several toxic air pollutants, including particulate matter, carbon monoxide, and polycyclic aromatic hydrocarbons. Air pollutant emissions depend on the type of wood and the technology and operational conditions of the wood stove. A better understanding of emissions from local wood species and wood stove performance would help to identify better biomass fuels and wood stove technologies in order to reduce air pollution from residential wood burning.

  18. Critical operational parameters for zero sludge production in biological wastewater treatment processes combined with sludge disintegration.

    PubMed

    Yoon, Seong-Hoon; Lee, Sangho

    2005-09-01

    Mathematical models were developed to elucidate the relationships among process control parameters and the effect of these parameters on the performance of anoxic/oxic biological wastewater processes combined with sludge disintegrators (A/O-SD). The model equations were also applied for analyses of activated sludge processes hybrid with sludge disintegrators (AS-SD). Solubilization ratio of sludge in the sludge disintegrator, alpha, hardly affected sludge reduction efficiencies if the biomass was completely destructed to smaller particulates. On the other hand, conversion efficiency of non-biodegradable particulates to biodegradable particulates, beta, significantly affected sludge reduction efficiencies because beta was directly related to the accumulation of non-biodegradable particulates in bioreactors. When 30% of sludge in the oxic tank was disintegrated everyday and beta was 0.5, sludge reduction was expected to be 78% and 69% for the A/O-SD and AS-SD processes, respectively. Under this condition, the sludge disintegration number (SDN), which is the amount of sludge disintegrated divided by the reduced sludge, was calculated to be around 4. Due to the sludge disintegration, live biomass concentration decreased while other non-biodegradable particulates concentration increased. As a consequence, the real F/M ratio was expected to be much higher than the apparent F/M. The effluent COD was maintained almost constant for the range of sludge disintegration rate considered in this study. Nitrogen removal efficiencies of the A/O-SD process was hardly affected by the sludge disintegration until daily sludge disintegration reaches 40% of sludge in the oxic tank. Above this level of sludge disintegration, autotrophic biomass concentration decreases overly and TKN in the effluent increases abruptly in both the A/O-SD and AS-SD processes. Overall, the trends of sludge reduction and effluent quality according to operation parameters matched well with experimental results found in literatures.

  19. Effect of flood events on transport of suspended sediments, organic matter and particulate metals in a forest watershed in the Basque Country (Northern Spain).

    PubMed

    Peraza-Castro, M; Sauvage, S; Sánchez-Pérez, J M; Ruiz-Romera, E

    2016-11-01

    An understanding of the processes controlling sediment, organic matter and metal export is critical to assessing and anticipating risk situations in water systems. Concentrations of suspended particulate matter (SPM), dissolved (DOC) and particulate (POC) organic carbon and metals (Cu, Ni, Pb, Cr, Zn, Mn, Fe) in dissolved and particulate phases were monitored in a forest watershed in the Basque Country (Northern Spain) (31.5km(2)) over three hydrological years (2009-2012), to evaluate the effect of flood events on the transport of these materials. Good regression was found between SPM and particulate metal concentration, making it possible to compute the load during the twenty five flood events that occurred during the study period at an annual scale. Particulate metals were exported in the following order: Fe>Mn>Zn>Cr>Pb>Cu>Ni. Annual mean loads of SPM, DOC and POC were estimated at 2267t, 104t and 57t, respectively, and the load (kg) of particulate metals at 76 (Ni), 83 (Cu), 135 (Pb), 256 (Cr), 532 (Zn), 1783 (Mn) and 95170 (Fe). Flood events constituted 91%-SPM, 65%-DOC, 71%-POC, 80%-Cu, 85%-Ni, 72%-Pb, 84%-Cr, 74%-Zn, 87%-Mn and 88%-Fe of total load exported during the three years studied. Flood events were classified into three categories according to their capacity for transporting organic carbon and particulate metals. High intensity flood events are those with high transport capacity of SPM, organic carbon and particulate metals. Most of the SPM, DOC, POC and particulate metal load was exported by this type of flood event, which contributed 59% of SPM, 45% of organic carbon and 54% of metals. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Measurement and analysis of ambient atmospheric particulate matter in urban and remote environments

    NASA Astrophysics Data System (ADS)

    Hagler, Gayle S. W.

    Atmospheric particulate matter pollution is a challenging environmental concern in both urban and remote locations worldwide. It is intrinsically difficult to control, given numerous anthropogenic and natural sources (e.g. fossil fuel combustion, biomass burning, dust, and seaspray) and atmospheric transport up to thousands of kilometers after production. In urban regions, fine particulate matter (particles with diameters under 2.5 mum) is of special concern for its ability to penetrate the human respiratory system and threaten cardiopulmonary health. A second major impact area is climate, with particulate matter altering Earth's radiative balance through scattering and absorbing solar radiation, modifying cloud properties, and reducing surface reflectivity after deposition in snow-covered regions. While atmospheric particulate matter has been generally well-characterized in populated areas of developed countries, particulate pollution in developing nations and remote regions is relatively unexplored. This thesis characterizes atmospheric particulate matter in locations that represent the extreme ends of the spectrum in terms of air pollution-the rapidly-developing and heavily populated Pearl River Delta Region of China, the pristine and climate-sensitive Greenland Ice Sheet, and a remote site in the Colorado Rocky Mountains. In China, fine particles were studied through a year-long field campaign at seven sites surrounding the Pearl River Delta. Fine particulate matter was analyzed for chemical composition, regional variation, and meteorological impacts. On the Greenland Ice Sheet and in the Colorado Rocky Mountains, the carbonaceous fraction (organic and elemental carbon) of particulate matter was studied in the atmosphere and snow pack. Analyses included quantifying particulate chemical and optical properties, assessing atmospheric transport, and evaluating post-depositional processing of carbonaceous species in snow.

  1. 40 CFR 63.7326 - How do I demonstrate initial compliance with the emission limitations that apply to me?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7326... coke oven battery subject to the emission limit for particulate matter from a control device applied to... process-weighted mass rate of particulate matter (lb/ton of coke), measured in accordance with the...

  2. 40 CFR 63.7326 - How do I demonstrate initial compliance with the emission limitations that apply to me?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7326... coke oven battery subject to the emission limit for particulate matter from a control device applied to... process-weighted mass rate of particulate matter (lb/ton of coke), measured in accordance with the...

  3. 40 CFR 63.7326 - How do I demonstrate initial compliance with the emission limitations that apply to me?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7326... coke oven battery subject to the emission limit for particulate matter from a control device applied to... process-weighted mass rate of particulate matter (lb/ton of coke), measured in accordance with the...

  4. 40 CFR 63.7326 - How do I demonstrate initial compliance with the emission limitations that apply to me?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7326... coke oven battery subject to the emission limit for particulate matter from a control device applied to... process-weighted mass rate of particulate matter (lb/ton of coke), measured in accordance with the...

  5. 40 CFR 63.7326 - How do I demonstrate initial compliance with the emission limitations that apply to me?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7326... coke oven battery subject to the emission limit for particulate matter from a control device applied to... process-weighted mass rate of particulate matter (lb/ton of coke), measured in accordance with the...

  6. Particulate Matter Stack Emission Compliance Test Procedure for Fuel Burning Units.

    ERIC Educational Resources Information Center

    West Virginia Air Pollution Control Commission, Charleston.

    This publication details the particulate matter emissions test procedure that is applicable for conducting compliance tests for fuel burning units required to be tested under Sub-section 7 of Regulation II (1972) as established by the state of West Virginia Air Pollution Control Commission. The testing procedure is divided into five parts:…

  7. 40 CFR 52.1638 - Bernalillo County particulate matter (PM10) Group II SIP commitments.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) New Mexico § 52.1638 Bernalillo County particulate matter (PM10) Group II SIP commitments. (a) On December 7, 1988, the Governor of New Mexico submitted a revision to the State Implementation Plan (SIP... SIPs. The City of Albuquerque and Bernalillo County Air Quality Control Board adopted this SIP revision...

  8. 40 CFR 52.1638 - Bernalillo County particulate matter (PM10) Group II SIP commitments.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) New Mexico § 52.1638 Bernalillo County particulate matter (PM10) Group II SIP commitments. (a) On December 7, 1988, the Governor of New Mexico submitted a revision to the State Implementation Plan (SIP... SIPs. The City of Albuquerque and Bernalillo County Air Quality Control Board adopted this SIP revision...

  9. Observed And Modeled Seasonal Trends In Dissolved And Particulate Cu, Fe, Mn, And Zn In A Mining-Impacted Stream

    EPA Science Inventory

    North Fork Clear Creek (NFCC) in Colorado, an acid-mine drainage (AMD) impacted stream, was chosen to examine the distribution of dissolved and particulate Cu, Fe, Mn, and Zn in the water column, with respect to seasonal hydrologic controls. NFCC is a high-gradient stream with d...

  10. Fine Ambient Particulate and Ozone Co-Exposures in Durham, North Carolina: Influence of Season on Particle Chemistry and Cardiovascular Responses in Rats

    EPA Science Inventory

    Epidemiological studies have shown that the presence of one air pollutant modifies the cardiovascular health effects of another while controlled exposure studies in humans have documented synergistic effects of co-exposure to ambient particulate matter (PM) and ozone (O3) on bloo...

  11. 40 CFR Table 2 to Subpart Fffff of... - Initial Compliance With Emission and Opacity Limits

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... flow-weighted average concentration of particulate matter from one or more control devices applied to...). 4. Each discharge end at a new sinter plant a. The flow-weighted average concentration of... BOPF at a new or existing BOPF shop a. The average concentration of particulate matter from a primary...

  12. 40 CFR Table 2 to Subpart Fffff of... - Initial Compliance With Emission and Opacity Limits

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... flow-weighted average concentration of particulate matter from one or more control devices applied to...). 4. Each discharge end at a new sinter plant a. The flow-weighted average concentration of... BOPF at a new or existing BOPF shop a. The average concentration of particulate matter from a primary...

  13. 40 CFR Table 2 to Subpart Fffff of... - Initial Compliance With Emission and Opacity Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flow-weighted average concentration of particulate matter from one or more control devices applied to...). 4. Each discharge end at a new sinter plant a. The flow-weighted average concentration of... BOPF at a new or existing BOPF shop a. The average concentration of particulate matter from a primary...

  14. 40 CFR Table 2 to Subpart Fffff of... - Initial Compliance With Emission and Opacity Limits

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... flow-weighted average concentration of particulate matter from one or more control devices applied to...). 4. Each discharge end at a new sinter plant a. The flow-weighted average concentration of... BOPF at a new or existing BOPF shop a. The average concentration of particulate matter from a primary...

  15. Transient particle emission measurement with optical techniques

    NASA Astrophysics Data System (ADS)

    Bermúdez, Vicente; Luján, José M.; Serrano, José R.; Pla, Benjamín

    2008-06-01

    Particulate matter is responsible for some respiratory and cardiovascular diseases. In addition, it is one of the most important pollutants of high-speed direct injection (HSDI) passenger car engines. Current legislation requires particulate dilution tunnels for particulate matter measuring. However for development work, dilution tunnels are expensive and sometimes not useful since they are not able to quantify real-time particulate emissions during transient operation. In this study, the use of a continuous measurement opacimeter and a fast response HFID is proven to be a good alternative to obtain instantaneous particle mass emissions during transient operation (due to particulate matter consisting mainly of soot and SOF). Some methods and correlations available from literature, but developed for steady conditions, are evaluated during transient operation by comparing with mini-tunnel measurements during the entire MVEG-A transient cycle. A new correlation was also derived from this evaluation. Results for soot and SOF (obtained from the new correlation proposed) are compared with soot and SOF captured with particulate filters, which have been separated by means of an SOF extraction method. Finally, as an example of ECU design strategies using these sort of correlations, the EGR valve opening is optimized during transient operation. The optimization is performed while simultaneously taking into account instantaneous fuel consumption, particulate emissions (calculated with the proposed correlation) and other regulated engine pollutants.

  16. Environmentally-friendly animal litter

    DOEpatents

    Boxley, Chett; McKelvie, Jessica

    2012-08-28

    An animal litter composition including geopolymerized ash particulates having a network of repeating aluminum-silicon units is described herein. Generally, the animal litter is made from a quantity of a pozzolanic ash mixed with a sufficient quantity of water and an alkaline activator to initiate a geopolymerization reaction that forms geopolymerized ash. After the geopolymerized ash is formed, it is dried, broken into particulates, and sieved to a desired size. These geopolymerized ash particulates are used to make a non-clumping or clumping animal litter. Odor control is accomplished with the addition of a urease inhibitor, pH buffer, an odor eliminating agent, and/or fragrance.

  17. Twelve-month, 12 km resolution North American WRF-Chem v3.4 air quality simulation: performance evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tessum, C. W.; Hill, J. D.; Marshall, J. D.

    We present results from and evaluate the performance of a 12-month, 12 km horizontal resolution year 2005 air pollution simulation for the contiguous United States using the WRF-Chem (Weather Research and Forecasting with Chemistry) meteorology and chemical transport model (CTM). We employ the 2005 US National Emissions Inventory, the Regional Atmospheric Chemistry Mechanism (RACM), and the Modal Aerosol Dynamics Model for Europe (MADE) with a volatility basis set (VBS) secondary aerosol module. Overall, model performance is comparable to contemporary modeling efforts used for regulatory and health-effects analysis, with an annual average daytime ozone (O 3) mean fractional bias (MFB) ofmore » 12% and an annual average fine particulate matter (PM 2.5) MFB of −1%. WRF-Chem, as configured here, tends to overpredict total PM 2.5 at some high concentration locations and generally overpredicts average 24 h O 3 concentrations. Performance is better at predicting daytime-average and daily peak O 3 concentrations, which are more relevant for regulatory and health effects analyses relative to annual average values. Predictive performance for PM 2.5 subspecies is mixed: the model overpredicts particulate sulfate (MFB = 36%), underpredicts particulate nitrate (MFB = −110%) and organic carbon (MFB = −29%), and relatively accurately predicts particulate ammonium (MFB = 3%) and elemental carbon (MFB = 3%), so that the accuracy in total PM 2.5 predictions is to some extent a function of offsetting over- and underpredictions of PM 2.5 subspecies. Model predictive performance for PM 2.5 and its subspecies is in general worse in winter and in the western US than in other seasons and regions, suggesting spatial and temporal opportunities for future WRF-Chem model development and evaluation.« less

  18. Twelve-month, 12 km resolution North American WRF-Chem v3.4 air quality simulation: performance evaluation

    DOE PAGES

    Tessum, C. W.; Hill, J. D.; Marshall, J. D.

    2015-04-07

    We present results from and evaluate the performance of a 12-month, 12 km horizontal resolution year 2005 air pollution simulation for the contiguous United States using the WRF-Chem (Weather Research and Forecasting with Chemistry) meteorology and chemical transport model (CTM). We employ the 2005 US National Emissions Inventory, the Regional Atmospheric Chemistry Mechanism (RACM), and the Modal Aerosol Dynamics Model for Europe (MADE) with a volatility basis set (VBS) secondary aerosol module. Overall, model performance is comparable to contemporary modeling efforts used for regulatory and health-effects analysis, with an annual average daytime ozone (O 3) mean fractional bias (MFB) ofmore » 12% and an annual average fine particulate matter (PM 2.5) MFB of −1%. WRF-Chem, as configured here, tends to overpredict total PM 2.5 at some high concentration locations and generally overpredicts average 24 h O 3 concentrations. Performance is better at predicting daytime-average and daily peak O 3 concentrations, which are more relevant for regulatory and health effects analyses relative to annual average values. Predictive performance for PM 2.5 subspecies is mixed: the model overpredicts particulate sulfate (MFB = 36%), underpredicts particulate nitrate (MFB = −110%) and organic carbon (MFB = −29%), and relatively accurately predicts particulate ammonium (MFB = 3%) and elemental carbon (MFB = 3%), so that the accuracy in total PM 2.5 predictions is to some extent a function of offsetting over- and underpredictions of PM 2.5 subspecies. Model predictive performance for PM 2.5 and its subspecies is in general worse in winter and in the western US than in other seasons and regions, suggesting spatial and temporal opportunities for future WRF-Chem model development and evaluation.« less

  19. Emission characteristics for gaseous- and size-segregated particulate PAHs in coal combustion flue gas from circulating fluidized bed (CFB) boiler.

    PubMed

    Wang, Ruwei; Liu, Guijian; Sun, Ruoyu; Yousaf, Balal; Wang, Jizhong; Liu, Rongqiong; Zhang, Hong

    2018-07-01

    The partitioning behavior of polycyclic aromatic hydrocarbons (PAHs) between gaseous and particulate phases from coal-fired power plants (CFPPs) is critically important to predict PAH removal by dust control devices. In this study, 16 US-EPA priority PAHs in gaseous and size-segregated particulate phases at the inlet and outlet of the fabric filter unit (FFs) of a circulating fluidized bed (CFB) boiler were analyzed. The partitioning mechanisms of PAHs between gaseous and particulate phases and in particles of different size classes were investigated. We found that the removal efficiencies of PAHs are 45.59% and 70.67-89.06% for gaseous and particulate phases, respectively. The gaseous phase mainly contains low molecular weight (LMW) PAHs (2- and 3-ring PAHs), which is quite different from the particulate phase that mainly contains medium and high molecular weight (MMW and HMW) PAHs (4- to 6-ring PAHs). The fractions of LMW PAHs show a declining trend with the decrease of particle size. The gas-particle partitioning of PAHs is primarily controlled by organic carbon absorption, in addition, it has a clear dependence on the particle sizes. Plot of log (TPAH/PM) against logD p shows that all slope values were below -1, suggesting that PAHs were mainly adsorbed to particulates. The adsorption effect of PAHs in size-segregated PMs for HMW PAHs is more evident than LMW PAHs. The particle size distributions (PSDs) of individual PAHs show that most of PAHs exhibit bi-model structures, with one mode peaking in the accumulation size range (2.1-1.1 μm) and another mode peaking in coarse size range (5.8-4.7 μm). The intensities of these two peaks vary in function of ring number of PAHs, which is likely attributed to Kelvin effect that the less volatile HMW PAH species preferentially condense onto the finer particulates. The emission factor of PAHs was calculated as 3.53 mg/kg of coal burned, with overall mean EF PAH of 0.55 and 2.98 mg/kg for gaseous and particulate phase, respectively. Moreover, the average emission amount of PAHs for the investigated CFPP was 1016.6 g/day and 371073.6 g/y, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Ash reduction system using electrically heated particulate matter filter

    DOEpatents

    Gonze, Eugene V [Pinckney, MI; Paratore, Jr., Michael J; He, Yongsheng [Sterling Heights, MI

    2011-08-16

    A control system for reducing ash comprises a temperature estimator module that estimates a temperature of an electrically heated particulate matter (PM) filter. A temperature and position estimator module estimates a position and temperature of an oxidation wave within the electrically heated PM filter. An ash reduction control module adjusts at least one of exhaust flow, fuel and oxygen levels in the electrically heated PM filter to adjust a position of the oxidation wave within the electrically heated PM filter based on the oxidation wave temperature and position.

Top