Neri, Tommaso; Pergoli, Laura; Petrini, Silvia; Gravendonk, Lotte; Balia, Cristina; Scalise, Valentina; Amoruso, Angela; Pedrinelli, Roberto; Paggiaro, Pierluigi; Bollati, Valentina; Celi, Alessandro
2016-04-01
Particulate airborne pollution is associated with increased cardiopulmonary morbidity. Microparticles are extracellular vesicles shed by cells upon activation or apoptosis involved in physiological processes such as coagulation and inflammation, including airway inflammation. We investigated the hypothesis that particulate matter causes the shedding of microparticles by human mononuclear and endothelial cells. Cells, isolated from the blood and the umbilical cords of normal donors, were cultured in the presence of particulate from a standard reference. Microparticles were assessed in the supernatant as phosphatidylserine concentration. Microparticle-associated tissue factor was assessed by an one-stage clotting assay. Nanosight technology was used to evaluate microparticle size distribution. Particulate matter induces a dose- and time- dependent, rapid (1h) increase in microparticle generation in both cells. These microparticles express functional tissue factor. Particulate matter increases intracellular calcium concentration and phospholipase C inhibition reduces microparticle generation. Nanosight analysis confirmed that upon exposure to particulate matter both cells express particles with a size range consistent with the definition of microparticles (50-1000 nm). Exposure of mononuclear and endothelial cells to particulate matter upregulates the generation of microparticles at least partially mediated by calcium mobilization. This observation might provide a further link between airborne pollution and cardiopulmonary morbidity. Copyright © 2016 Elsevier B.V. All rights reserved.
MODELING ENVIRONMENTAL EXPOSURES TO PARTICULATE MATTER AND PESTICIDES
This presentation describes initial results from on-going research at EPA on modeling human exposures to particulate matter and residential pesticides. A first generation probabilistic population exposure model for Particulate Matter (PM), specifically for predicting PM1o and P...
40 CFR 60.43b - Standard for particulate matter (PM).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter (PM). 60.43b Section 60.43b Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Industrial-Commercial-Institutional Steam Generating Units § 60.43b Standard for particulate matter (PM). (a...
40 CFR 60.43c - Standard for particulate matter (PM).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter (PM). 60.43c Section 60.43c Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Industrial-Commercial-Institutional Steam Generating Units § 60.43c Standard for particulate matter (PM). (a...
NASA Astrophysics Data System (ADS)
Swamy, S.; Power, J.; Pham, D.; Preston, K. B.; Iqbal, A.
2007-12-01
Human and animal activity that occurs on gravel and dirt roads tends to contribute to high levels of particulate matter in the atmosphere. Birds molt their feathers, automobiles emit unused residues, and humans and animals stir up debris on the ground. Not only do these activities generate particulate matter, but they also generate noise. The aim of our study was to determine if a direct correlation exists between the amount of particulate matter and the noise levels in select areas within the Lake Merritt Park region of downtown Oakland, California. In addition, our research was aimed at determining if the level of noise at various locations conforms to City of Oakland regulations. Over a four-week period we measured noise levels and particulate matter concentrations at 27 different sites within the Park region. Preliminary results indicate that at a construction site and a residential area near the lake a direct correlation between our two variables existed; high noise level accompanied high particulate matter while low noise level accompanied low particulate matter, respectively. However, at the majority of the areas around the lake either indirect or no correlation was observed. Based on our results thus far, we conclude that noise levels are not indicative of particulate matter levels and that noise levels around Lake Merritt do conform to the city's regulations.
Generation of hydroxyl radicals by urban suspended particulate air matter. The role of iron ions
NASA Astrophysics Data System (ADS)
Valavanidis, Athanasios; Salika, Anastasia; Theodoropoulou, Anna
Recent epidemiologic studies showed statistical associations between particulate air pollution in urban areas and increased morbidity and mortality, even at levels well within current national air quality standards. Inhalable particulate matter (PM 10) can penetrate into the lower airways where they can cause acute and chronic lung injury by generating toxic oxygen free radicals. We tested inhalable total suspended particulates (TSP) from the Athens area, diesel and gasoline exhaust particles (DEP and GED), and urban street dusts, by Electron Paramagnetic Resonance (EPR). All particulates can generate hydroxyl radicals (HO ṡ), in aqueous buffered solutions, in the presence of hydrogen peroxide. Results showed that oxidant generating activity is related with soluble iron ions. Leaching studies showed that urban particulate matter can release large amounts of Fe 3+ and lesser amounts of Fe 2+, as it was shown from other studies. Direct evidence of HO ṡ was confirmed by spin trapping with DMPO and measurement of DMPO-OH adduct by EPR. Evidence was supported with the use of chelator (EDTA), which increases the EPR signal, and the inhibition of the radical generating activity by desferrioxamine or/and antioxidants ( D-mannitol, sodium benzoate).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Compliance and performance test methods and procedures for particulate matter and nitrogen oxides. 60.46b Section 60.46b Protection of... Generating Units § 60.46b Compliance and performance test methods and procedures for particulate matter and...
NASA Astrophysics Data System (ADS)
Baitimirova, M.; Osite, A.; Katkevics, J.; Viksna, A.
2012-08-01
Burning of candles generates particulate matter of fine dimensions that produces poor indoor air quality, so it may cause harmful impact on human health. In this study solid aerosol particles of burning of candles of different composition and kerosene combustion were collected in a closed laboratory system. Present work describes particulate matter collection for structure analysis and the relationship between source and size distribution of particulate matter. The formation mechanism of particulate matter and their tendency to agglomerate also are described. Particles obtained from kerosene combustion have normal size distribution. Whereas, particles generated from the burning of stearin candles have distribution shifted towards finer particle size range. If an additive of stearin to paraffin candle is used, particle size distribution is also observed in range of towards finer particles. A tendency to form agglomerates in a short time is observed in case of particles obtained from kerosene combustion, while in case of particles obtained from burning of candles of different composition such a tendency is not observed. Particles from candles and kerosene combustion are Aitken and accumulation mode particles
Nayek, Sukanta; Padhy, Pratap Kumar
2018-06-01
More than 85% of the rural Indian households use traditional solid biofuels (SBFs) for daily cooking. Burning of the easily available unprocessed solid fuels in inefficient earthen cooking stoves produce large quantities of particulate matters. Smaller particulates, especially with aerodynamic diameter of 2.5 μm or less (PM 2.5 ), largely generated during cooking, are considered to be health damaging in nature. In the present study, kitchen level exposure of women cooks to fine particulate matters during lunch preparation was assessed considering kitchen openness as surrogate to the ventilation condition. Two-way ANCOVA analysis considering meal quantity as a covariate revealed no significant interaction between the openness and the seasons explaining the variability of the personal exposure to the fine particulate matters in rural kitchen during cooking. Multiple linear regression analysis revealed the openness as the only significant predictor for personal exposure to the fine particulate matters. In the present study, the annual average fine particulate matter exposure concentration was found to be 974 μg m -3 .
An enhanced research paradigm is presented to address the spatial and temporal gaps in fine particulate matter (PM2.5) measurements and generate realistic and representative concentration fields for use in epidemiological studies of human exposure to ambient air particulate conce...
A multi-phase instrument comparison study was conducted on two different diesel engines on a dynamometer to compare commonly used particulate matter (PM) measurement techniques while sampling the same diesel exhaust aerosol and to evaluate inter- and intra-method variability. In...
Improved methods for measuring and assessing microenvironmental exposure in individuals are needed. How human activities affect particulate matter in the personal cloud is poorly understood. A quality assurance tool to aid the study of particle transport mechanisms (e.g., re-en...
Comparative In Vivo and Ex Vivo Toxicity Studies of Wildfire Particulate Matter
Inhalation of particulate matter (PM) generated from biomass burning is of concern particularly as the frequency and severity of wildfires have been increasing. Size-fractionated PM samples (ultrafine, <0.2 µm; fine, 0.2-2.5 µm; coarse, 2.5-10 µm) were colle...
Effect of Feeding Schedule on Fractionated Particulate Matter Distribution in Rooster House
USDA-ARS?s Scientific Manuscript database
The persistence and long life expectancy of ammonia, odors and toxic pollutants from poultry houses may be due to the ability of suspended particulate matters (SPM) to serve as carriers for odorous compounds such as ammonium ions and volatile organic compounds. SPM is generated from the feed, anima...
40 CFR 60.42 - Standard for particulate matter (PM).
Code of Federal Regulations, 2013 CFR
2013-07-01
... Fossil-Fuel-Fired Steam Generators § 60.42 Standard for particulate matter (PM). (a) Except as provided... fossil fuel or fossil fuel and wood residue. (2) Exhibit greater than 20 percent opacity except for one... owner or operator of an affected facility that combusts only gaseous or liquid fossil fuel (excluding...
40 CFR 60.42 - Standard for particulate matter (PM).
Code of Federal Regulations, 2012 CFR
2012-07-01
... Fossil-Fuel-Fired Steam Generators § 60.42 Standard for particulate matter (PM). (a) Except as provided... fossil fuel or fossil fuel and wood residue. (2) Exhibit greater than 20 percent opacity except for one... owner or operator of an affected facility that combusts only gaseous or liquid fossil fuel (excluding...
40 CFR 60.42 - Standard for particulate matter (PM).
Code of Federal Regulations, 2014 CFR
2014-07-01
... Fossil-Fuel-Fired Steam Generators § 60.42 Standard for particulate matter (PM). (a) Except as provided... fossil fuel or fossil fuel and wood residue. (2) Exhibit greater than 20 percent opacity except for one... owner or operator of an affected facility that combusts only gaseous or liquid fossil fuel (excluding...
Impact of feed delivery pattern on aerial particulate matter and behavior of feedlot cattle
USDA-ARS?s Scientific Manuscript database
Fine particulate matter (PM) generated by cattle in feedlots is an environmental pollutant and a potential human and animal health issue. The objective of this study was to determine if a feeding schedule affects cattle behaviors that promote PM in a commercial feedlot. The study used 2,813 crossbre...
USDA-ARS?s Scientific Manuscript database
The persistence and long life expectancy of ammonia, odors and toxic pollutants from poultry houses may be due to the ability of suspended particulate matters (SPM) to serve as carriers for odorous compounds such as ammonium ions and volatile organic compounds. SPM is generated from the feed, anima...
This dataset provides all data used to generate the figures and tables in the article entitled Particulate matter and black carbon optical properties and emission factors from prescribed fires in the southeastern United States published in the Journal of Geophysical Research: AtmospheresThis dataset is associated with the following publication:Holder , A., G. Hagler , J. Aurell, M. Hays , and B. Gullett. Particulate matter and black carbon optical properties and emission factors from prescribed fires in the southeastern United States. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES. American Geophysical Union, Washington, DC, USA, 121(7): 3465-3483, (2016).
NASA Technical Reports Server (NTRS)
Perry, J. L.; Agui, J. H.; Vijayakimar, R
2016-01-01
Contaminants generated aboard crewed spacecraft by diverse sources consist of both gaseous chemical contaminants and particulate matter. Both HEPA media filters and packed beds of granular material, such as activated carbon, which are both commonly employed for cabin atmosphere purification purposes have efficacy for removing nanoparticulate contaminants from the cabin atmosphere. The phenomena associated with particulate matter removal by HEPA media filters and packed beds of granular material are reviewed relative to their efficacy for removing fine (less than 2.5 micrometers) and ultrafine (less than 0.01 micrometers) sized particulate matter. Considerations are discussed for using these methods in an appropriate configuration to provide the most effective performance for a broad range of particle sizes including nanoparticulates.
Particulate matter emissions from combustion of wood in district heating applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghafghazi, S.; Sowlati, T.; Sokhansanj, Shahabaddine
2011-01-01
The utilization of wood biomass to generate district heat and power in communities that have access to this energy source is increasing. In this paper the effect of wood fuel properties, combustion condition, and flue gas cleaning system on variation in the amount and formation of particles in the flue gas of typical district heating wood boilers are discussed based on the literature survey. Direct measurements of particulate matter (PM) emissions from wood boilers with district heating applications are reviewed and presented. Finally, recommendations are given regarding the selection of wood fuel, combustion system condition, and flue gas cleaning systemmore » in district heating systems in order to meet stringent air quality standards. It is concluded that utilization of high quality wood fuel, such as wood pellets produced from natural, uncontaminated stem wood, would generate the least PM emissions compared to other wood fuel types. Particulate matter emissions from grate burners equipped with electrostatic precipitators when using wood pellets can be well below stringent regulatory emission limit such as particulate emission limit of Metro Vancouver, Canada.« less
NASA Astrophysics Data System (ADS)
Stone, Elizabeth; Jayarathne, Thilina; Stockwell, Chelsea; Christian, Ted; Bhave, Prakash; Siva Praveen, Puppala; Panday, Arnico; Adhikari, Sagar; Maharjan, Rashmi; Goetz, Doug; DeCarlo, Peter; Saikawa, Eri; Yokelson, Robert
2016-04-01
The Nepal Ambient Monitoring and Source Testing Experiment (NAMASTE) field campaign targeted the in situ characterization of widespread and under-sampled combustion sources. In Kathmandu and the Terai, southern Nepal's flat plains, samples of fine particulate matter (PM2.5) were collected from wood and dung cooking fires (n = 22), generators (n = 2), groundwater pumps (n = 2), clamp kilns (n = 3), zig-zag kilns (n = 3), trash burning (n = 4), one heating fire, and one crop residue fire. Co-located measurements of carbon dioxide, carbon monoxide, and volatile organic compounds allowed for the application of the carbon mass balance approach to estimate emission factors for PM2.5, elemental carbon, organic carbon, and water-soluble inorganic ions. Organic matter was chemically speciated using gas chromatography - mass spectrometry for polycyclic aromatic hydrocarbons, sterols, n-alkanes, hopanes, steranes, and levoglucosan, which accounted for 2-8% of the measured organic carbon. These data were used to develop molecular-marker based profiles for use in source apportionment modeling. This study provides quantitative emission factors for particulate matter and its constituents for many important combustion sources in Nepal and South Asia.
Hydrocarbon-enhanced particulate filter regeneration via microwave ignition
Gonze, Eugene V.; Brown, David B.
2010-02-02
A regeneration method for a particulate filter includes estimating a quantity of particulate matter trapped within the particulate filter, comparing the quantity of particulate matter to a predetermined quantity, heating at least a portion of the particulate filter to a combustion temperature of the particulate matter, and introducing hydrocarbon fuel to the particulate filter. The hydrocarbon fuel facilitates combustion of the particulate matter to regenerate the particulate filter.
Jørgensen, Rikke Bramming; Kero, Ida Teresia
2017-12-20
Airborne particulate matter in the silicon carbide (SiC) industry is a known health hazard. The aims of this study were to elucidate whether the particulate matter generated inside the Acheson furnace during active operation is representative of the overall particulate matter in the furnace hall, and whether the Acheson furnaces are the main sources of ultrafine particles (UFP) in primary SiC production. The number concentration of ultrafine particles was evaluated using an Electrical Low Pressure Impactor (ELPI TM , Dekati Ltd., Tampere, Finland), a Fast Mobility Particle Sizer (FMPS TM , TSI, Shoreview, MN, USA) and a Condensation Particle Counter (CPC, TSI, Shoreview, MN, USA). The results are discussed in terms of particle number concentration, particle size distribution and are also characterized by means of electron microscopy (TEM/SEM). Two locations were investigated; the industrial Acheson process furnace hall and a pilot furnace hall; both of which represent an active operating furnace. The geometric mean of the particle number concentration in the Acheson process furnace hall was 7.7 × 10⁴ particles/cm³ for the UFP fraction and 1.0 × 10⁵ particles/cm³ for the submicrometre fraction. Particulate matter collected at the two sites was analysed by electron microscopy. The PM from the Acheson process furnace hall is dominated by carbonaceous particles while the samples collected near the pilot furnace are primarily rich in silicon.
2017-01-01
Airborne particulate matter in the silicon carbide (SiC) industry is a known health hazard. The aims of this study were to elucidate whether the particulate matter generated inside the Acheson furnace during active operation is representative of the overall particulate matter in the furnace hall, and whether the Acheson furnaces are the main sources of ultrafine particles (UFP) in primary SiC production. The number concentration of ultrafine particles was evaluated using an Electrical Low Pressure Impactor (ELPITM, Dekati Ltd., Tampere, Finland), a Fast Mobility Particle Sizer (FMPSTM, TSI, Shoreview, MN, USA) and a Condensation Particle Counter (CPC, TSI, Shoreview, MN, USA). The results are discussed in terms of particle number concentration, particle size distribution and are also characterized by means of electron microscopy (TEM/SEM). Two locations were investigated; the industrial Acheson process furnace hall and a pilot furnace hall; both of which represent an active operating furnace. The geometric mean of the particle number concentration in the Acheson process furnace hall was 7.7 × 104 particles/cm3 for the UFP fraction and 1.0 × 105 particles/cm3 for the submicrometre fraction. Particulate matter collected at the two sites was analysed by electron microscopy. The PM from the Acheson process furnace hall is dominated by carbonaceous particles while the samples collected near the pilot furnace are primarily rich in silicon. PMID:29261158
Modeling particulate matter emissions during mineral loading process under weak wind simulation.
Zhang, Xiaochun; Chen, Weiping; Ma, Chun; Zhan, Shuifen
2013-04-01
The quantification of particulate matter emissions from mineral handling is an important problem for the quantification of global emissions on industrial sites. Mineral particulate matter emissions could adversely impact environmental quality in mining regions, transport regions, and even on a global scale. Mineral loading is an important process contributing to mineral particulate matter emissions, especially under weak wind conditions. Mathematical models are effective ways to evaluate particulate matter emissions during the mineral loading process. The currently used empirical models based on the form of a power function do not predict particulate matter emissions accurately under weak wind conditions. At low particulate matter emissions, the models overestimated, and at high particulate matter emissions, the models underestimated emission factors. We conducted wind tunnel experiments to evaluate the particulate matter emission factors for the mineral loading process. A new approach based on the mathematical form of a logistical function was developed and tested. It provided a realistic depiction of the particulate matter emissions during the mineral loading process, accounting for fractions of fine mineral particles, dropping height, and wind velocity. Copyright © 2013 Elsevier B.V. All rights reserved.
Processing and Analysis of Multibeam Sonar Data and Images near the Yellow River Estuary
NASA Astrophysics Data System (ADS)
Tang, Q.
2017-12-01
Yellow River Estuary is a typical high-suspended particulate matter estuary in the world. A lot of sediments from Yellow River and other substances produced by human activity cause high-concentration suspended matter and depositional system in the estuary and adjacent water area. Multibeam echo sounder (MBES) was developed in the 1970s, and it not only provided high-precision bathymetric data, but also provided seabed backscatter strength data and water column data with high temporal and spatial resolution. Here, based on high-precision sonar data of the seabed and water column collected by SeaBat7125 MBES system near the Yellow River Estuary, we use advanced data and image processing methods to generate seabed sonar images and water suspended particulate matter acoustic images. By analyzing these data and images, we get a lot of details of the seabed and whole water column features, and we also acquire their shape, size and basic physical characteristics of suspended particulate matters in the experiment area near the Yellow River Estuary. This study shows great potential for monitoring suspended particulate matter use MBES, and the research results will contribute to a comprehensive understanding of sediment transportation, evolution of river trough and shoal in Yellow River Estuary.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-25
...-AR30 Implementation of the New Source Review (NSR) Program for Particulate Matter Less Than 2.5... Particulate Matter AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: The EPA is... for particulate matter (PM) known as ``particulate matter emissions'' in the context of the PSD and...
Characteristics of particulate matter emissions from toy cars with electric motors.
Wang, Xiaofei; Williams, Brent J; Biswas, Pratim
2015-04-01
Aerosol emissions from toy cars with electric motors were characterized. Particle emission rates from the toy cars, as high as 7.47×10(7) particles/s, were measured. This emission rate is lower than other indoor sources such as smoking and cooking. The particles emitted from toy cars are generated from spark discharges inside the electric motors that power the toy cars. Size distribution measurements indicated that most particles were below 100 nm in diameter. Copper was the dominant inorganic species in these particles. By deploying aerosol mass spectrometers, high concentrations of particulate organic matter were also detected and characterized in detail. Several organic compounds were identified using a thermal desorption aerosol gas chromatography. The mass size distribution of particulate organic matter was bimodal. The formation mechanism of particulate organic matter from toy cars was elucidated. A possible new source of indoor air pollution, particles from electric motors in toy cars, was identified. This study characterized aerosol emissions from toy cars in detail. Most of these particles have a diameter less than 100 nm. Copper and some organics are the major components of these particles. Conditions that minimize these emissions were determined.
40 CFR 60.422 - Standards for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for particulate matter. 60... Manufacture § 60.422 Standards for particulate matter. On or after the date on which the performance test... sulfate dryer, particulate matter at an emission rate exceeding 0.15 kilogram of particulate per megagram...
40 CFR 60.422 - Standards for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for particulate matter. 60... Manufacture § 60.422 Standards for particulate matter. On or after the date on which the performance test... sulfate dryer, particulate matter at an emission rate exceeding 0.15 kilogram of particulate per megagram...
40 CFR 60.422 - Standards for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for particulate matter. 60... Manufacture § 60.422 Standards for particulate matter. On or after the date on which the performance test... sulfate dryer, particulate matter at an emission rate exceeding 0.15 kilogram of particulate per megagram...
40 CFR 60.422 - Standards for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for particulate matter. 60... Manufacture § 60.422 Standards for particulate matter. On or after the date on which the performance test... sulfate dryer, particulate matter at an emission rate exceeding 0.15 kilogram of particulate per megagram...
2013-01-01
Underground railway stations are known to have elevated particulate matter (PM) loads compared to ambient air. As these particles are derived from metal-rich sources and transition metals may pose a risk to health by virtue of their ability to catalyze generation of reactive oxygen species (ROS), their potential enrichment in underground environments is a source of concern. Compared to coarse (PM10) and fine (PM2.5) particulate fractions of underground railway airborne PM, little is known about the chemistry of the ultrafine (PM0.1) fraction that may contribute significantly to particulate number and surface area concentrations. This study uses inductively coupled plasma mass spectrometry and ion chromatography to compare the elemental composition of size-fractionated underground PM with woodstove, roadwear generator, and road tunnel PM. Underground PM is notably rich in Fe, accounting for greater than 40% by mass of each fraction, and several other transition metals (Cu, Cr, Mn, and Zn) compared to PM from other sources. Importantly, ultrafine underground PM shows similar metal-rich concentrations as the coarse and fine fractions. Scanning electron microscopy revealed that a component of the coarse fraction of underground PM has a morphology indicative of generation by abrasion, absent for fine and ultrafine particulates, which may be derived from high-temperature processes. Furthermore, underground PM generated ROS in a concentration- and size-dependent manner. This study suggests that the potential health effects of exposure to the ultrafine fraction of underground PM warrant further investigation as a consequence of its greater surface area/volume ratio and high metal content. PMID:23477491
30 CFR 57.5075 - Diesel particulate records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Diesel particulate records. 57.5075 Section 57..., Radiation, Physical Agents, and Diesel Particulate Matter Diesel Particulate Matter-Underground Only § 57.5075 Diesel particulate records. (a) The table entitled “Diesel Particulate Matter Recordkeeping...
30 CFR 57.5075 - Diesel particulate records.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Diesel particulate records. 57.5075 Section 57..., Radiation, Physical Agents, and Diesel Particulate Matter Diesel Particulate Matter-Underground Only § 57.5075 Diesel particulate records. (a) The table entitled “Diesel Particulate Matter Recordkeeping...
Lung, Shih-Chun Candice; Hu, Shu-Chuan
2003-02-01
The generation rates and emission factors of particulate matter and associated polycyclic aromatic hydrocarbons (PAHs) from incense burning were assessed in a laboratory setting. The differences among different segments of the same stick, among different sticks of the same kind of incense, and between two kinds of manually made Chih-Chen incense sticks (A and B) were evaluated. Joss sticks were burned inside a 44 cm long elutriator; personal environmental monitors fitted into the top of the elutriator were used to take PM2.5 and PM10 samples of incense smoke. Samples were analyzed for PAHs by gas chromatography-flame ionization Detector. It was found that particle and associated PAHs were generated approximately at 561 microg/min (geometric standard deviation (GSD) = 1.1) and 0.56 microg/min (GSD = 1.1) from Incense A, and at 661 microg/min (GSD = 1.7) and 0.46 microg/min (GSD = 1.3) from Incense B, respectively. One gram of Incense A emitted about 19.8 mg (GSD = 1.1) particulate matter and 17.1 microg (GSD = 1.2) particulate-phase PAHs, while one gram of Incense B produced around 43.6 mg (GSD = 1.1) of particles and 25.2 microg (GSD = 1.2) of particle-bound PAHs. There were significant differences in emissions between Incenses A and B, although they belong to the same class of incense. A 10-20% variability in emissions was observed in the main part of the manually produced stick, and a larger variation was found at both tips of the combustible part.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-02
... Promulgation of Air Quality Implementation Plans; Wisconsin; Particulate Matter Standards; Withdrawal of Direct... were made to the particulate matter standards by adding fine particulate standards and revoking the..., Intergovernmental relations, Particulate matter. Authority: 42 U.S.C. 7401 et seq. Dated: May 14, 2010. Walter W...
Controls on mineral dust emissions at four arid locations in the western USA
NASA Astrophysics Data System (ADS)
Engelbrecht, Johann P.; Gillies, John A.; Etyemezian, Vicken; Kuhns, Hampden; Baker, Sophie E.; Zhu, Dongzi; Nikolich, George; Kohl, Steven D.
Dust emission measurements from unique military sources, including tracked and wheeled military vehicles, low flying rotary-winged aircraft, and artillery backblast, were conducted in the course of four field campaigns in 2005-2008, at Yuma Proving Ground (YPG) in Arizona (twice), Yakima Test Center (YTC) in Washington State, and Ft. Carson in Colorado. This paper reports on the observed relationships between levels of dust emission, and the mineralogy, particle size, and chemical composition of the surface sediment and associated airborne mineral dust. We propose a mechanism for the generation of fine particulate matter, providing an explanation for high emissions in certain regions. PM10 (particulate matter with aerodynamic diameter of <10 μm) and PM2.5 (particulate matter with aerodynamic diameter of <2.5 μm) filter as well as bulk samples were collected for laboratory analysis in the course of the field campaigns. Analytical techniques applied include X-ray diffraction, Scanning Electron Microscopy, laser particle size analysis, as well as X-ray fluorescence spectrometry, Ion Chromatography, and Automated Colorimetry. Previous work has shown YTC has higher dust emission factors than YPG and Ft. Carson. The results presented in this paper demonstrate that the high PM10 and PM2.5 emissions measured at YTC can be explained by the high silt and low clay content of the surface sediment, attributed to glacial loess. In the other test areas, the abrasion of microscopic clay and oxide coatings, from and by silicate mineral grains, is considered a factor in the generation of fine particulate matter.
40 CFR 52.2059 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) Pennsylvania has committed to undertake a comprehensive program... Investigating and Controlling Nontraditional Particulate Matter Emissions Task Completion date Scheduled tasks...
40 CFR 52.2059 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) Pennsylvania has committed to undertake a comprehensive program... Investigating and Controlling Nontraditional Particulate Matter Emissions Task Completion date Scheduled tasks...
40 CFR 52.2059 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) Pennsylvania has committed to undertake a comprehensive program... Investigating and Controlling Nontraditional Particulate Matter Emissions Task Completion date Scheduled tasks...
40 CFR 52.2059 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) Pennsylvania has committed to undertake a comprehensive program... Investigating and Controlling Nontraditional Particulate Matter Emissions Task Completion date Scheduled tasks...
40 CFR 89.404 - Test procedure overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engine operating conditions to be conducted on an engine dynamometer. The exhaust gases, generated raw or... matter. For more information on particulate matter sampling see § 89.112(c). The test cycles consist of... (raw analysis), and the power output during each mode. The measured values are weighted and used to...
40 CFR 52.228 - Regulations: Particulate matter, Southeast Desert Intrastate Region.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Regulations: Particulate matter... § 52.228 Regulations: Particulate matter, Southeast Desert Intrastate Region. (a) The following... particulate matter in the Southeast Desert Intrastate Region. (1) Imperial County Air Pollution Control...
40 CFR 52.228 - Regulations: Particulate matter, Southeast Desert Intrastate Region.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Regulations: Particulate matter... § 52.228 Regulations: Particulate matter, Southeast Desert Intrastate Region. (a) The following... particulate matter in the Southeast Desert Intrastate Region. (1) Imperial County Air Pollution Control...
40 CFR 52.776 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter...: Particulate matter. Link to an amendment published at 78 FR 28507, May 15, 2013. (a) The requirements of... the secondary standards for particulate matter in the Metropolitan Indianapolis Intrastate Region. (b...
40 CFR 52.2276 - Control strategy and regulations: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Particulate matter. 52.2276 Section 52.2276 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....2276 Control strategy and regulations: Particulate matter. (a) Part D conditional approval. The Texas... of the fabric filters, Parker Brothers and Co., Inc., shall not emit particulate matter in excess of...
40 CFR 52.1678 - Control strategy and regulations: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Particulate matter. 52.1678 Section 52.1678 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1678 Control strategy and regulations: Particulate matter. (a)-(c) [Reserved] (d) Section 227.3(a... CFR Subpart G, Control strategy: Sulfur oxides and particulate matter. (e) Determination of Attainment...
Particulate Matter Filtration Design Considerations for Crewed Spacecraft Life Support Systems
NASA Technical Reports Server (NTRS)
Agui, Juan H.; Vijayakumar, R.; Perry, Jay L.
2016-01-01
Particulate matter filtration is a key component of crewed spacecraft cabin ventilation and life support system (LSS) architectures. The basic particulate matter filtration functional requirements as they relate to an exploration vehicle LSS architecture are presented. Particulate matter filtration concepts are reviewed and design considerations are discussed. A concept for a particulate matter filtration architecture suitable for exploration missions is presented. The conceptual architecture considers the results from developmental work and incorporates best practice design considerations.
Kuki, Kacilda Naomi; Oliva, Marco Antônio; Pereira, Eduardo Gusmão; Costa, Alan Carlos; Cambraia, José
2008-09-15
Particulate matter is a natural occurrence in the environment, but some industries, such as the iron ore sector, can raise the total amount of particles in the atmosphere. This industry is primarily a source of iron and sulfur dioxide particulates. The effects of the pollutants from the iron ore industries on representatives of restinga vegetation in a Brazilian coastal ecosystem were investigated using physiological and biochemical measures. Two species, Schinus terebinthifolius and Sophora tomentosa, were exposed to simulated deposition of acid mist and iron ore particulate matter in acrylic chambers in a greenhouse. Parameters such as gas exchange, fluorescence emission, chlorophyll content, total iron content, antioxidant enzyme activity and malondialdehyde content were assessed in order to evaluate the responses of the two species. Neither treatment was capable of inducing oxidative stress in S. terebinthifolius. Nevertheless, the deposition of iron ore particulates on this species increased chlorophyll content, the maximum quantum efficiency of photosystem II and the electron transport rate, while iron content was unaltered. On the other hand, S. tomentosa showed a greater sensitivity to the treatments. Plants of S. tomentosa that were exposed to acid mist had a decrease in photosynthesis, while the deposition of iron particulate matter led to an increase in iron content and membrane permeability of the leaves. The activities of antioxidant enzymes, such as catalases and superoxide dismutase, were enhanced by both treatments. The results suggested that the two restinga species use different strategies to overcome the stressful conditions created by the deposition of particulate matter, either solid or wet. It seems that while S. terebinthifolius avoided stress, S. tomentosa used antioxidant enzyme systems to partially neutralize oxidative stress. The findings also point to the potential use of S. tomentosa as a biomarker species under field conditions.
40 CFR 52.1476 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter in...
40 CFR 60.172 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 52.776 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for attainment and maintenance of the secondary standards for particulate matter in the...
40 CFR 52.2584 - Control strategy; Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...
40 CFR 60.532 - Standards for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for particulate matter. 60... Wood Heaters § 60.532 Standards for particulate matter. Unless exempted under § 60.530, each affected..., 1992, shall comply with the following particulate matter emission limits as determined by the test...
40 CFR 60.172 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 52.2584 - Control strategy; Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...
40 CFR 60.162 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-08
... Promulgation of Air Quality Implementation Plans; Wisconsin; Particulate Matter Standards AGENCY: Environmental... matter standards in October 2006 by strengthening the 24-hour fine particulate standard and revoking the... standards to match the current Federal standards for particulate matter. DATES: Comments must be received on...
40 CFR 52.776 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for attainment and maintenance of the secondary standards for particulate matter in the...
40 CFR 52.1476 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter in...
40 CFR 60.172 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 60.162 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 52.1476 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter in...
40 CFR 60.532 - Standards for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for particulate matter. 60... Wood Heaters § 60.532 Standards for particulate matter. Unless exempted under § 60.530, each affected..., 1992, shall comply with the following particulate matter emission limits as determined by the test...
40 CFR 52.2584 - Control strategy; Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...
40 CFR 52.2584 - Control strategy; Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...
40 CFR 52.2584 - Control strategy; Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not contain...
40 CFR 60.172 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 60.162 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 60.162 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 60.162 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.162... Smelters § 60.162 Standard for particulate matter. (a) On and after the date on which the performance test... particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 52.2059 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) [Reserved] (b) EPA approves the PM-10 attainment demonstration...-Wilmington, PA-NJ-DE fine particulate matter (PM2.5) nonattainment area has attained the 2006 24-hour PM2.5...
40 CFR 60.532 - Standards for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for particulate matter. 60... Wood Heaters § 60.532 Standards for particulate matter. Unless exempted under § 60.530, each affected..., 1992, shall comply with the following particulate matter emission limits as determined by the test...
40 CFR 60.532 - Standards for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for particulate matter. 60... Wood Heaters § 60.532 Standards for particulate matter. Unless exempted under § 60.530, each affected..., 1992, shall comply with the following particulate matter emission limits as determined by the test...
40 CFR 60.172 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.172... Smelters § 60.172 Standard for particulate matter. (a) On and after the date on which the performance test... contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). ...
40 CFR 52.1476 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter in...
Code of Federal Regulations, 2011 CFR
2011-07-01
... flue gases at the inlet of my particulate matter control device? 60.1325 Section 60.1325 Protection of... the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate... particulate matter control device. ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... flue gases at the inlet of my particulate matter control device? 60.1325 Section 60.1325 Protection of... the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate... particulate matter control device. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-26
... Promulgation of Air Quality Implementation Plans; Ohio; Particulate Matter Standards AGENCY: Environmental... in Ohio Administrative Code (OAC) Chapter 3745-17, ``Particulate Matter Standards.'' The revisions were submitted by Ohio EPA to satisfy the State's 5-year review requirements. The particulate matter...
40 CFR 52.126 - Control strategy and regulations: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Particulate matter. 52.126 Section 52.126 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... strategy and regulations: Particulate matter. (a) The requirements of subpart G and § 51.281 of this... the national standards for particulate matter in Gila, Maricopa, Pima, Pinal, and Santa Cruz Counties...
Code of Federal Regulations, 2010 CFR
2010-07-01
...: Particulate matter, Metropolitan Los Angeles Intrastate Region. 52.227 Section 52.227 Protection of... IMPLEMENTATION PLANS California § 52.227 Control strategy and regulations: Particulate matter, Metropolitan Los... does not provide for attainment and maintenance of the secondary standards for particulate matter in...
40 CFR 49.126 - Rule for limiting fugitive particulate matter emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Rule for limiting fugitive particulate matter emissions. (a) What is the purpose of this section? This section limits the amount of fugitive particulate matter that may be emitted from certain air pollution... source of fugitive particulate matter emissions. (c) What is exempted from this section? This section...
40 CFR 63.1357 - Temporary, conditioned exemption from particulate matter and opacity standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... particulate matter and opacity standards. 63.1357 Section 63.1357 Protection of Environment ENVIRONMENTAL... Cement Manufacturing Industry Other § 63.1357 Temporary, conditioned exemption from particulate matter... methods) is exempt from: (1) Any particulate matter and opacity standards of part 60 or part 63 of this...
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Particulate matter, Metropolitan Los Angeles Intrastate Region. 52.227 Section 52.227 Protection of... IMPLEMENTATION PLANS California § 52.227 Control strategy and regulations: Particulate matter, Metropolitan Los... does not provide for attainment and maintenance of the secondary standards for particulate matter in...
Toxicity of inhaled traffic related particulate matter
NASA Astrophysics Data System (ADS)
Gerlofs-Nijland, Miriam E.; Campbell, Arezoo; Miller, Mark R.; Newby, David E.; Cassee, Flemming R.
2009-02-01
Traffic generated ultrafine particulates may play a major role in the development of adverse health effects. However, little is known about harmful effects caused by recurring exposure. We hypothesized that repeated exposure to particulate matter results in adverse pulmonary and systemic toxic effects. Exposure to diesel engine exhaust resulted in signs of oxidative stress in the lung, impaired coagulation, and changes in the immune system. Pro-inflammatory cytokine levels were decreased in some regions of the brain but increased in the striatum implying that exposure to diesel engine exhaust may selectively aggravate neurological impairment. Data from these three studies suggest that exposure to traffic related PM can mediate changes in the vasculature and brain of healthy rats. To what extent these changes may contribute to chronic neurodegenerative or vascular diseases is at present unclear.
Particulate contamination removal from wafers using plasmas and mechanical agitation
Selwyn, G.S.
1998-12-15
Particulate contamination removal from wafers is disclosed using plasmas and mechanical agitation. The present invention includes the use of plasmas with mechanical agitation for removing particulate matter from the surface of a wafer. The apparatus hereof comprises a mechanical activator, at least one conducting contact pin for transferring the vibration from the activator to the wafer, clamp fingers that maintain the wafer`s position, and means for generating a plasma in the vicinity of the surface of the wafer, all parts of the cleaning apparatus except the mechanical activator and part of the contact pin being contained inside the processing chamber. By exposing a wafer to a plasma and providing motion thereto in a direction perpendicular to its surface, the bonding between the particulate matter and the surface may be overcome. Once free of the wafer surface, the particulates become charged by electrons from the plasma and are drawn into the plasma by attractive forces which keep them from redepositing. The introduction of a flowing gas through the plasma sweeps the particulates away from the wafer and out of the plasma. The entire surface is cleaned during one cleaning step. The use of an rf plasma to accomplish the particulate removal was found to remove more than 90% of the particulates. 4 figs.
Particulate contamination removal from wafers using plasmas and mechanical agitation
Selwyn, Gary S.
1998-01-01
Particulate contamination removal from wafers using plasmas and mechanical agitation. The present invention includes the use of plasmas with mechanical agitation for removing particulate matter from the surface of a wafer. The apparatus hereof comprises a mechanical activator, at least one conducting contact pin for transferring the vibration from the activator to the wafer, clamp fingers that maintain the wafer's position, and means for generating a plasma in the vicinity of the surface of the wafer, all parts of the cleaning apparatus except the mechanical activator and part of the contact pin being contained inside the processing chamber. By exposing a wafer to a plasma and providing motion thereto in a direction perpendicular to its surface, the bonding between the particulate matter and the surface may be overcome. Once free of the wafer surface, the particulates become charged by electrons from the plasma and are drawn into the plasma by attractive forces which keep them from redepositing. The introduction of a flowing gas through the plasma sweeps the particulates away from the wafer and out of the plasma. The entire surface is cleaned during one cleaning step. The use of an rf plasma to accomplish the particulate removal was found to remove more than 90% of the particulates.
Code of Federal Regulations, 2011 CFR
2011-07-01
... diesel-powered equipment other than generators and compressors. 72.502 Section 72.502 Mineral Resources... FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.502 Requirements for nonpermissible light-duty diesel-powered equipment other than generators and compressors. (a...
Code of Federal Regulations, 2010 CFR
2010-07-01
... diesel-powered equipment other than generators and compressors. 72.502 Section 72.502 Mineral Resources... FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.502 Requirements for nonpermissible light-duty diesel-powered equipment other than generators and compressors. (a...
Basics of Sterile Compounding: Particulate Matter.
Akers, Michael J
2017-01-01
This article focuses on the requirements for particulate matter in sterile products. Topics include particles and quality, particulate matter standards (large- and small-volume injectables), development of the small-volume injectable test, electronic (light obscuration) and microscope testing, and special requirements for particulate matter in biopharmaceutical preparations. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
40 CFR 60.732 - Standards for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for particulate matter. 60... Dryers in Mineral Industries § 60.732 Standards for particulate matter. Each owner or operator of any... particulate matter in excess of 0.092 gram per dry standard cubic meter (g/dscm) [0.040 grain per dry standard...
40 CFR 60.182 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...
40 CFR 60.132 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.132... and Bronze Production Plants § 60.132 Standard for particulate matter. (a) On and after the date on... reverberatory furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf...
40 CFR 60.262 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.262... Production Facilities § 60.262 Standard for particulate matter. (a) On and after the date on which the... furnace any gases which: (1) Exit from a control device and contain particulate matter in excess of 0.45...
40 CFR 60.342 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.342... Manufacturing Plants § 60.342 Standard for particulate matter. (a) On and after the date on which the... gases which: (1) Contain particulate matter in excess of 0.30 kilogram per megagram (0.60 lb/ton) of...
40 CFR 60.292 - Standards for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for particulate matter. 60... Manufacturing Plants § 60.292 Standards for particulate matter. (a) On and after the date on which the..., particulate matter at emission rates exceeding those specified in table CC-1, Column 2 and Column 3...
40 CFR 60.732 - Standards for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for particulate matter. 60... Dryers in Mineral Industries § 60.732 Standards for particulate matter. Each owner or operator of any... particulate matter in excess of 0.092 gram per dry standard cubic meter (g/dscm) [0.040 grain per dry standard...
40 CFR 60.132 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.132... and Bronze Production Plants § 60.132 Standard for particulate matter. (a) On and after the date on... reverberatory furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf...
40 CFR 60.472 - Standards for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for particulate matter. 60... Processing and Asphalt Roofing Manufacture § 60.472 Standards for particulate matter. (a) On and after the...) Particulate matter in excess of: (i) 0.04 kg/Mg (0.08 lb/ton) of asphalt shingle or mineral-surfaced roll...
40 CFR 60.262 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.262... Production Facilities § 60.262 Standard for particulate matter. (a) On and after the date on which the... furnace any gases which: (1) Exit from a control device and contain particulate matter in excess of 0.45...
40 CFR 60.52 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...
40 CFR 60.182 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...
40 CFR 60.292 - Standards for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for particulate matter. 60... Manufacturing Plants § 60.292 Standards for particulate matter. (a) On and after the date on which the..., particulate matter at emission rates exceeding those specified in table CC-1, Column 2 and Column 3...
40 CFR 60.382 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.382... Processing Plants § 60.382 Standard for particulate matter. (a) On and after the date on which the... stack emissions that: (1) Contain particulate matter in excess of 0.05 grams per dry standard cubic...
40 CFR 60.302 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.302... § 60.302 Standard for particulate matter. (a) On and after the 60th day of achieving the maximum... a grain dryer any process emission which: (1) Contains particulate matter in excess of 0.023 g/dscm...
40 CFR 60.732 - Standards for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for particulate matter. 60... Dryers in Mineral Industries § 60.732 Standards for particulate matter. Each owner or operator of any... particulate matter in excess of 0.092 gram per dry standard cubic meter (g/dscm) [0.040 grain per dry standard...
40 CFR 60.52 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...
40 CFR 52.427 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) Determination of attainment. EPA has determined, as of May 16, 2012, that based on... fine particulate matter (PM2.5) nonattainment area has attained the 2006 24-hour PM2.5 national ambient...
40 CFR 60.302 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.302... § 60.302 Standard for particulate matter. (a) On and after the 60th day of achieving the maximum... a grain dryer any process emission which: (1) Contains particulate matter in excess of 0.023 g/dscm...
40 CFR 60.342 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.342... Manufacturing Plants § 60.342 Standard for particulate matter. (a) On and after the date on which the... gases which: (1) Contain particulate matter in excess of 0.30 kilogram per megagram (0.60 lb/ton) of...
40 CFR 60.382 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.382... Processing Plants § 60.382 Standard for particulate matter. (a) On and after the date on which the... stack emissions that: (1) Contain particulate matter in excess of 0.05 grams per dry standard cubic...
40 CFR 60.132 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.132... and Bronze Production Plants § 60.132 Standard for particulate matter. (a) On and after the date on... reverberatory furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf...
40 CFR 60.472 - Standards for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for particulate matter. 60... Processing and Asphalt Roofing Manufacture § 60.472 Standards for particulate matter. (a) On and after the...) Particulate matter in excess of: (i) 0.04 kg/Mg (0.08 lb/ton) of asphalt shingle or mineral-surfaced roll...
40 CFR 60.292 - Standards for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for particulate matter. 60... Manufacturing Plants § 60.292 Standards for particulate matter. (a) On and after the date on which the..., particulate matter at emission rates exceeding those specified in table CC-1, Column 2 and Column 3...
40 CFR 60.302 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.302... § 60.302 Standard for particulate matter. (a) On and after the 60th day of achieving the maximum... a grain dryer any process emission which: (1) Contains particulate matter in excess of 0.023 g/dscm...
40 CFR 60.52 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...
40 CFR 60.382 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.382... Processing Plants § 60.382 Standard for particulate matter. (a) On and after the date on which the... stack emissions that: (1) Contain particulate matter in excess of 0.05 grams per dry standard cubic...
40 CFR 52.427 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) Determination of attainment. EPA has determined, as of May 16, 2012, that based on... fine particulate matter (PM2.5) nonattainment area has attained the 2006 24-hour PM2.5 national ambient...
40 CFR 60.472 - Standards for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for particulate matter. 60... Processing and Asphalt Roofing Manufacture § 60.472 Standards for particulate matter. (a) On and after the...) Particulate matter in excess of: (i) 0.04 kg/Mg (0.08 lb/ton) of asphalt shingle or mineral-surfaced roll...
40 CFR 60.182 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...
40 CFR 60.302 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.302... § 60.302 Standard for particulate matter. (a) On and after the 60th day of achieving the maximum... a grain dryer any process emission which: (1) Contains particulate matter in excess of 0.023 g/dscm...
40 CFR 60.52 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...
40 CFR 60.52 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.52... § 60.52 Standard for particulate matter. (a) On and after the date on which the initial performance... atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0...
40 CFR 60.132 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.132... and Bronze Production Plants § 60.132 Standard for particulate matter. (a) On and after the date on... reverberatory furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf...
40 CFR 60.262 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.262... Production Facilities § 60.262 Standard for particulate matter. (a) On and after the date on which the... furnace any gases which: (1) Exit from a control device and contain particulate matter in excess of 0.45...
40 CFR 60.732 - Standards for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for particulate matter. 60... Dryers in Mineral Industries § 60.732 Standards for particulate matter. Each owner or operator of any... particulate matter in excess of 0.092 gram per dry standard cubic meter (g/dscm) [0.040 grain per dry standard...
40 CFR 60.182 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...
40 CFR 60.132 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.132... and Bronze Production Plants § 60.132 Standard for particulate matter. (a) On and after the date on... reverberatory furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf...
40 CFR 60.292 - Standards for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for particulate matter. 60... Manufacturing Plants § 60.292 Standards for particulate matter. (a) On and after the date on which the..., particulate matter at emission rates exceeding those specified in table CC-1, Column 2 and Column 3...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-26
... Cleveland/Akron, Ohio Submitted Annual Fine Particulate Matter Attainment Demonstration for Transportation... (MVEBs) for fine particulate matter (PM 2.5 ) and oxides of nitrogen (NO X ) as a precursor to fine particulate matter in the Cleveland/Akron, Ohio area are adequate for use in transportation conformity...
40 CFR 60.292 - Standards for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for particulate matter. 60... Manufacturing Plants § 60.292 Standards for particulate matter. (a) On and after the date on which the..., particulate matter at emission rates exceeding those specified in table CC-1, Column 2 and Column 3...
40 CFR 60.342 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.342... Manufacturing Plants § 60.342 Standard for particulate matter. (a) On and after the date on which the... gases which: (1) Contain particulate matter in excess of 0.30 kilogram per megagram (0.60 lb/ton) of...
40 CFR 60.302 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.302... § 60.302 Standard for particulate matter. (a) On and after the 60th day of achieving the maximum... a grain dryer any process emission which: (1) Contains particulate matter in excess of 0.023 g/dscm...
40 CFR 60.182 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.182... Smelters § 60.182 Standard for particulate matter. (a) On and after the date on which the performance test... furnace, or sintering machine discharge end any gases which contain particulate matter in excess of 50 mg...
40 CFR 60.472 - Standards for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for particulate matter. 60... Processing and Asphalt Roofing Manufacture § 60.472 Standards for particulate matter. (a) On and after the...) Particulate matter in excess of: (i) 0.04 kg/Mg (0.08 lb/ton) of asphalt shingle or mineral-surfaced roll...
40 CFR 60.262 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.262... Production Facilities § 60.262 Standard for particulate matter. (a) On and after the date on which the... furnace any gases which: (1) Exit from a control device and contain particulate matter in excess of 0.45...
40 CFR 60.382 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.382... Processing Plants § 60.382 Standard for particulate matter. (a) On and after the date on which the... stack emissions that: (1) Contain particulate matter in excess of 0.05 grams per dry standard cubic...
Urban tree effects on fine particulate matter and human health
David J. Nowak
2014-01-01
Overall, city trees reduce particulate matter and provide substantial health benefits; but under certain conditions, they can locally increase particulate matter concentrations. Urban foresters need to understand how trees affect particulate matter so they can select proper species and create appropriate designs to improve air quality. This article details trees'...
Environmental Issues in Managing Asthma
Diette, Gregory B; McCormack, Meredith C; Hansel, Nadia N; Breysse, Patrick N; Matsui, Elizabeth C
2008-01-01
Management of asthma requires attention to environmental exposures both indoors and outdoors. Americans spend most of their time indoors, where they have a greater ability to modify their environment. The indoor environment contains both pollutants (eg, particulate matter, nitrogen dioxide, secondhand smoke, and ozone) and allergens from furred pets, dust mites, cockroaches, rodents, and molds. Indoor particulate matter consists of particles generated from indoor sources such as cooking and cleaning activities, and particles that penetrate from the outdoors. Nitrogen dioxide sources include gas stoves, furnaces, and fireplaces. Indoor particulate matter and nitrogen dioxide are linked to asthma morbidity. The indoor ozone concentration is mainly influenced by the outdoor ozone concentration. The health effects of indoor ozone exposure have not been well studied. In contrast, there is substantial evidence of detrimental health effects from secondhand smoke. Guideline recommendations are not specific for optimizing indoor air quality. The 2007 National Asthma Education and Prevention Program asthma guidelines recommend eliminating indoor smoking and improving the ventilation. Though the guidelines state that there is insufficient evidence to recommend air cleaners, air cleaners and reducing activities that generate indoor pollutants may be sound practical approaches for improving the health of individuals with asthma. The guidelines are more specific about allergen avoidance; they recommend identifying allergens to which the individual is immunoglobin E sensitized and employing a multifaceted, comprehensive strategy to reduce exposure. Outdoor air pollutants that impact asthma include particulate matter, ozone, nitrogen dioxide, and sulfur dioxide, and guidelines recommend that individuals with asthma avoid exertion outdoors when these pollutants are elevated. Outdoor allergens include tree, grass, and weed pollens, which vary in concentration by season. Recommendations to reduce exposure include staying indoors, keeping windows and doors closed, using air conditioning and perhaps high-efficiency particulate arrestor (HEPA) air filters, and thorough daily washing to remove allergens from one’s person. PMID:18426614
Forero, Luis Gabriel; Limay-Rios, Victor; Xue, Yingen; Schaafsma, Arthur
2017-12-01
Atmospheric emissions of neonicotinoid seed treatment insecticides as particulate matter in field crops occur mainly for two reasons: 1) due to abraded dust of treated seed generated during planting using vacuum planters, and 2) as a result of disturbances (tillage or wind events) in the surface of parental soils which release wind erodible soil-bound residues. In the present study, concentration and movement of neonicotinoids as particulate matter were quantified under real conditions using passive and active air samplers. Average neonicotinoid concentrations in Total Suspended Particulate (TSP) using passive samplers were 0.48 ng/cm 2 , trace, trace (LOD 0.80 and 0.04 ng/cm 2 for clothianidin and thiamethoxam, respectively), and using active samplers 16.22, 1.91 and 0.61 ng/m 3 during planting, tillage and wind events, respectively. There was a difference between events on total neonicotinoid concentration collected in particulate matter using either passive or active sampling. Distance of sampling from the source field during planting of treated seed had an effect on total neonicotinoid air concentration. However, during tillage distance did not present an effect on measured concentrations. Using hypothetical scenarios, values of contact exposure for a honey bee were estimated to be in the range from 1.1% to 36.4% of the reference contact LD 50 value of clothianidin of 44 ng/bee. Copyright © 2017 Elsevier Ltd. All rights reserved.
Twardella, D; Fromme, H; Dietrich, S; Dietrich, W C
2009-02-01
The aims of the research project were (I) to describe the exposure to particulate matter in Bavarian schools and identify predictors of increased exposure and (II) to evaluate whether exposure can be reduced by improving the ventilation and/or cleaning routine. Air quality was measured in 46 schools, two classrooms each, in the City of Munich and Dachau county. Each classroom was measured on one school day in both winter 2004/2005 and summer 2005. The continuously generated data on particulate matter during the teaching hours were summarised to daily medians and the possible association of the median concentration with classroom characteristics was tested using non-parametric methods. In winter, the median PM (2.5) concentration was 18.8 microg/m (3), in summer 12.7 microg/m (3). The median PM (10) concentration was 91.5 microg/m (3) in winter and 64.9 microg/m (3) in summer. Determinants of a high particulate matter concentration were the winter period, an increased number of pupils or decreased room size, a high CO(2) concentration, and a low class level. Following this survey, a pilot study on the effects of improved cleaning and ventilation routines was conducted in autumn 2005. Three conditions were tested in two classrooms of one school: (a) standard, (b) improved airing (3 min during short and 20 min during long breaks), and (c) improved airing and improved cleaning (thorough cleaning once and vacuuming before wet wiping). Each condition was implemented for 2 weeks and particulate matter concentrations measured concurrently. In both rooms a reduction of both PM (2.5) and PM (10) concentration was found following improved airing and a further reduction occurred when improved cleaning was introduced in addition. However, in a linear regression accounting for other factors (room, physical activity of the pupils, outdoor concentration of particulate matter) the effect of improved airing was no longer significant, while the effect of improved cleaning remained at a reduction of 6 microg/m (3) for PM (2.5) and of 30 microg/m (3) for PM (10). The research projects show, that exposure to particulate matter in schools is high and indicate that, in particular, improved cleaning may be an effective measure to reduce the indoor particulate matter concentration. More and larger studies are needed to prove the efficacy of this measure.
Kiepper, B H; Merka, W C; Fletcher, D L
2008-08-01
An experiment was conducted to compare the proximate composition of particulate matter recovered from poultry processing wastewater (PPW) generated by broiler slaughter plants. Poultry processing wastewater is the cumulative wastewater stream generated during the processing of poultry following primary and secondary physical screening (typically to 500 mum) that removes gross offal. Composite samples of PPW from 3 broiler slaughter plants (southeast United States) were collected over 8 consecutive weeks. All 3 broiler slaughter plants process young chickens with an average live weight of 2.0 kg. At each plant, a single 72-L composite sample was collected using an automatic sampler programmed to collect 1 L of wastewater every 20 min for 24 h during one normal processing day each week. Each composite sample was thoroughly mixed, and 60 L was passed through a series of sieves (2.0 mm, 1.0 mm, 500 mum, and 53 mum). The amount of particulate solids collected on the 2.0 mm, 1.0 mm, and 500 mum sieves was insignificant. The solids recovered from the 53-mum sieve were subjected to proximate analysis to determine percent moisture, fat, protein, ash, and fiber. The average percentages of fat, protein, ash, and fiber for all samples on a dry-weight basis were 55.3, 27.1, 6.1, and 4.1, respectively. Fat made up over half of the dry-weight matter recovered, representing PPW particulate matter between 500 and 53 mum. Despite the variation in number of birds processed daily, further processing operations, and number and type of wastewater screens utilized, there were no significance differences in percentage of fat and fiber between the slaughter plants. There were significant differences in percent protein and ash between the slaughter plants.
40 CFR 60.682 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.682... Insulation Manufacturing Plants § 60.682 Standard for particulate matter. On and after the date on which the... gases which contain particulate matter in excess of 5.5 kg/Mg (11.0 1b/ton) of glass pulled. ...
40 CFR 60.142a - Standards for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for particulate matter. 60... 20, 1983 § 60.142a Standards for particulate matter. (a) Except as provided under paragraphs (b) and...-blown BOPF and contain particulate matter in excess of 23 mg/dscm (0.010 gr/dscf). (3) Exit from a...
40 CFR 60.142a - Standards for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for particulate matter. 60... 20, 1983 § 60.142a Standards for particulate matter. (a) Except as provided under paragraphs (b) and...-blown BOPF and contain particulate matter in excess of 23 mg/dscm (0.010 gr/dscf). (3) Exit from a...
40 CFR 60.682 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.682... Insulation Manufacturing Plants § 60.682 Standard for particulate matter. On and after the date on which the... gases which contain particulate matter in excess of 5.5 kg/Mg (11.0 1b/ton) of glass pulled. ...
40 CFR 60.122 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...
40 CFR 60.92 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...
40 CFR 60.272a - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...
40 CFR 60.92 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...
40 CFR 60.122 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...
40 CFR 60.682 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.682... Insulation Manufacturing Plants § 60.682 Standard for particulate matter. On and after the date on which the... gases which contain particulate matter in excess of 5.5 kg/Mg (11.0 1b/ton) of glass pulled. ...
40 CFR 60.272a - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...
40 CFR 60.682 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.682... Insulation Manufacturing Plants § 60.682 Standard for particulate matter. On and after the date on which the... gases which contain particulate matter in excess of 5.5 kg/Mg (11.0 1b/ton) of glass pulled. ...
40 CFR 60.272 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.272... Standard for particulate matter. (a) On and after the date on which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf). (2) Exit from a...
40 CFR 60.92 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...
40 CFR 60.122 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...
40 CFR 60.152 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...
40 CFR 60.142a - Standards for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for particulate matter. 60... 20, 1983 § 60.142a Standards for particulate matter. (a) Except as provided under paragraphs (b) and...-blown BOPF and contain particulate matter in excess of 23 mg/dscm (0.010 gr/dscf). (3) Exit from a...
40 CFR 60.152 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...
40 CFR 60.92 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...
40 CFR 60.272a - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...
40 CFR 60.122 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...
40 CFR 60.122 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.122... Smelters § 60.122 Standard for particulate matter. (a) On and after the date on which the performance test... furnace any gases which: (1) Contain particulate matter in excess of 50 mg/dscm (0.022 gr/dscf). (2...
40 CFR 60.142a - Standards for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for particulate matter. 60... 20, 1983 § 60.142a Standards for particulate matter. (a) Except as provided under paragraphs (b) and...-blown BOPF and contain particulate matter in excess of 23 mg/dscm (0.010 gr/dscf). (3) Exit from a...
40 CFR 60.272 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.272... Standard for particulate matter. (a) On and after the date on which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf). (2) Exit from a...
40 CFR 60.152 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...
40 CFR 60.272a - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...
40 CFR 60.92 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.92... Facilities § 60.92 Standard for particulate matter. (a) On and after the date on which the performance test... which: (1) Contain particulate matter in excess of 90 mg/dscm (0.04 gr/dscf). (2) Exhibit 20 percent...
40 CFR 60.152 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...
40 CFR 60.682 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for particulate matter. 60.682... Insulation Manufacturing Plants § 60.682 Standard for particulate matter. On and after the date on which the... gases which contain particulate matter in excess of 5.5 kg/Mg (11.0 1b/ton) of glass pulled. ...
40 CFR 60.142a - Standards for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for particulate matter. 60... 20, 1983 § 60.142a Standards for particulate matter. (a) Except as provided under paragraphs (b) and...-blown BOPF and contain particulate matter in excess of 23 mg/dscm (0.010 gr/dscf). (3) Exit from a...
40 CFR 60.272 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for particulate matter. 60.272... Standard for particulate matter. (a) On and after the date on which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf). (2) Exit from a...
40 CFR 60.152 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for particulate matter. 60.152... Plants § 60.152 Standard for particulate matter. (a) On and after the date on which the performance test...: (1) Particulate matter at a rate in excess of 0.65 g/kg dry sludge input (1.30 lb/ton dry sludge...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Process Heaters With Particulate Matter Emission Limits 2 Table 2 to Subpart DDDDD of Part 63 Protection... Heaters With Particulate Matter Emission Limits As stated in § 63.7500, you must comply with the applicable operating limits: If you demonstrate compliance with applicable particulate matter emission limits...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Process Heaters With Particulate Matter Emission Limits 2 Table 2 to Subpart DDDDD of Part 63 Protection... Heaters With Particulate Matter Emission Limits As stated in § 63.7500, you must comply with the applicable operating limits: If you demonstrate compliance with applicable particulate matter emission limits...
40 CFR 60.272a - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60... Standard for particulate matter. (a) On and after the date of which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf); (2) Exit from a...
40 CFR 60.272 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter. 60.272... Standard for particulate matter. (a) On and after the date on which the performance test required to be... control device and contain particulate matter in excess of 12 mg/dscm (0.0052 gr/dscf). (2) Exit from a...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Agents, and Diesel Particulate Matter Diesel Particulate Matter-Underground Only § 57.5067 Engines. (a... (2) Meet or exceed the applicable particulate matter emission requirements of the Environmental...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Mijung; Liu, Pengfei F.; Hanna, Sarah J.
To improve predictions of air quality, visibility, and climate change, knowledge of the viscosities and diffusion rates within organic particulate matter consisting of secondary organic material (SOM) is required. Most qualitative and quantitative measurements of viscosity and diffusion rates within organic particulate matter have focused on SOM particles generated from biogenic volatile organic compounds (VOCs) such as α-pinene and isoprene. In this study, we quantify the relative humidity (RH)-dependent viscosities at 295±1K of SOM produced by photo-oxidation of toluene, an anthropogenic VOC. The viscosities of toluene-derived SOM were 2 × 10 ₋1 to ~6 ×10 6Pa s from 30 tomore » 90%RH, and greater than ~2 × 10 8 Pa s (similar to or greater than the viscosity of tar pitch) for RH ≤ 17%. These viscosities correspond to Stokes–Einstein-equivalent diffusion coefficients for large organic molecules of ~2 ×10 ₋15cm 2s ₋1 for 30 % RH, and lower than ~3 × 10 ₋17cm 2s ₋1 for RH ≤ 17 %. Based on these estimated diffusion coefficients, the mixing time of large organic molecules within 200 nm toluene-derived SOM particles is 0.1–5 h for 30% RH, and higher than ~100 h for RH ≤ 17%. As a starting point for understanding the mixing times of large organic molecules in organic particulate matter over cities, we applied the mixing times determined for toluene-derived SOM particles to the world's top 15 most populous megacities. If the organic particulate matter in these megacities is similar to the toluene-derived SOM in this study, in Istanbul, Tokyo, Shanghai, and São Paulo, mixing times in organic particulate matter during certain periods of the year may be very short, and the particles may be well-mixed. On the other hand, the mixing times of large organic molecules in organic particulate matter in Beijing, Mexico City, Cairo, and Karachi may be long and the particles may not be well-mixed in the afternoon (15:00–17:00 LT) during certain times of the year.« less
Establishing the origin of particulate matter across Europe
NASA Astrophysics Data System (ADS)
Schaap, Martijn; Kranenburg, Richard; Hendriks, Carlijn; Kuenen, Jeroen
2016-04-01
Exposure to particulate matter (PM) in ambient air leads to adverse health effects. To design cost effective mitigation strategies, a thorough understanding of the sources of particulate matter is crucial. In this paper we like to provide an overview of recent source apportionment studies aimed at PM and its precursors carried out at TNO. The source apportionment module that tracks the origin of modelled particulate matter distributions throughout a LOTOS-EUROS simulation will be explained. To optimally apply this technology dedicated emission inventories, e.g. fuel type specific, need to be generated. Applications to Europe shows that in northwestern Europe the contribution of transport and agricultural emissions dominate the PM mass concentrations, especially during episodic events. In eastern Europe, the domestic and energy sector are much more important. In southern Europe the picture is more mixed, although the frequent high levels of desert dust stand out. Evaluation of the source allocation against experimental data and PMF analyses is challenging as there is only a limited availability of source specific tracers or factors that can be used for direct comparison. Nonetheless, for the available tracers such as vanadium for heavy fuel oil combustion an evaluation is very well possible. The source apportionment technique can also be used to interpret particulate matter formation efficiencies. It will be shown that the conversion rates for the secondary inorganic aerosol precursors (NOx, NH3 and SO2) have changed during the last 20 years. A particular problem is related to the fact that CTMs systematically underestimate observed PM levels, which means that the contribution of certain source categories (natural, agriculture, combustion) are underestimated. Future developments needed to improve the source apportionment information concerning process knowledge, data assimilation as well as model implementation will be discussed. Specific challenges concerning the underlying emission information will be highlighted.
Code of Federal Regulations, 2011 CFR
2011-07-01
... flue gases at the inlet of my particulate matter control device? 60.1815 Section 60.1815 Protection of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You... flue gas stream at the inlet of each particulate matter control device. ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... flue gases at the inlet of my particulate matter control device? 60.1815 Section 60.1815 Protection of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You... flue gas stream at the inlet of each particulate matter control device. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-29
... Subject to BART 3. BART Determination for Kanoelehua Hill a. BART for NO X and Particulate Matter (PM) b.... The initials PM mean or refer to particulate matter. xxiv. The initials PM2.5 mean or refer to particulate matter with an aerodynamic diameter of less than 2.5 micrometers (fine particulate matter). xxv...
Status of Suspended Particulate Matters Pollution at Traditional Markets in Makassar City
NASA Astrophysics Data System (ADS)
Suryani, Sri; Fahrunnisa
2018-03-01
Research on the status of suspended particulate matters pollution in four traditional markets located in Makassar city has been done. The purpose of this research is to know the air quality in the traditional market areas, especially caused by suspended particulate matters. The background of this research is because traders who trade in traditional markets generally peddle their goods along dusty roads and suspended particulate matters in dust can be inhaled when the vehicle passes. These suspended particulate matters pollutant can cause lung diseases. The results showed that the level of suspended particulate matters pollution fluctuates every year depending on the local wind speed, humidity, and temperature. Research results also showed the values were over the standard value according to the governor of South Sulawesi regulation.
The contribution of outdoor particulate matter (PM) to residential indoor concentrations is currently not well understood. Most importantly, separating indoor PM into indoor- and outdoor-generated components will greatly enhance our knowledge of the outdoor contribution to tot...
NASA Astrophysics Data System (ADS)
Rahman, Habibur M.; Kennedy, Martin; Löhr, Stefan; Dewhurst, David N.; Sherwood, Neil; Yang, Shengyu; Horsfield, Brian
2018-01-01
Accurately assessing the temperature and hence the depth and timing of hydrocarbon generation is a critical step in the characterization of a petroleum system. Clay catalysis is a potentially significant modifier of hydrocarbon generation temperature, but experimental studies of clay catalysis show inconsistent or contradictory results. This study tests the hypothesis that source rock fabric itself is an influence on clay mineral catalysis as it controls the extent to which organic matter and clay minerals are physically associated. Two endmember clay-organic fabrics distinguish the source rocks studied: (1) a particulate fabric where organic matter is present as discrete, >5 μm particles and (2) a nanocomposite fabric in which amorphous organic matter is associated with clay mineral surfaces at sub-micron scale. High-resolution electron imaging and bulk geochemical characterisation confirm that samples of the Miocene Monterey Formation (California) are representative of the nanocomposite source rock endmember, whereas samples from the Permian Stuart Range Formation (South Australia) represent the particulate source rock endmember. Kinetic experiments are performed on paired whole rock and kerogen isolate samples from these two formations using open system, non-isothermal pyrolysis at three different heating rates (0.7, 2 and 5 K/min) to determine the effects of the different shale fabrics on hydrocarbon generation kinetics. Extrapolation to a modelled geological heating rate shows a 20 °C reduction in the onset temperature of hydrocarbon generation in Monterey Formation whole rock samples relative to paired kerogen isolates. This result is consistent with the Monterey Formations's nanocomposite fabric where clay catalysis can proceed because reactive clay minerals are intimately associated with organic matter. By contrast, there is no significant difference in the modelled hydrocarbon generation temperature of paired whole rock and kerogen isolates from the Stuart Range Formation. This is consistent with its particulate fabric, where relatively large, discrete organic particles have limited contact with the mineral matrix and the clay minerals are mainly diagenetic and physically segregated within pores. While heating rate may have a control on mineral matrix effects, this result shows that the extent to which organic matter and clay minerals are physically associated could have a significant effect on the timing of hydrocarbon generation, and is a function of the depositional environment and detrital vs diagenetic origin of clay minerals in source rocks.
Code of Federal Regulations, 2010 CFR
2010-07-01
... flue gases at the inlet of my particulate matter control device? 62.15270 Section 62.15270 Protection....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... flue gases at the inlet of my particulate matter control device? 62.15270 Section 62.15270 Protection....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...
40 CFR 52.1476 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... National Ambient Air Quality Standards for particulate matter. (1) NAQR Article 7.2.7, Particulate Matter; Table 4.2, Emissions Inventory Summary for Particulates and Table 5.2, Summary of Control Strategy... 24, 1979. (2) Nevada Air Quality Regulations, Article 4, Rule 4.34, (Visible Emission from Stationary...
Storey, John Morse; Curran, Scott J.; Lewis, Samuel A.; ...
2016-08-04
Low-temperature compression ignition combustion can result in nearly smokeless combustion, as indicated by a smoke meter or other forms of soot measurement that rely on absorbance due to elemental carbon content. Highly premixed low-temperature combustion modes do not form particulate matter in the traditional pathways seen with conventional diesel combustion. Previous research into reactivity controlled compression ignition particulate matter has shown, despite a near zero smoke number, significant mass can be collected on filter media used for particulate matter certification measurement. In addition, particulate matter size distributions reveal that a fraction of the particles survive heated double-dilution conditions. This papermore » summarizes research completed at Oak Ridge National Laboratory to date on characterizing the nature, chemistry and aftertreatment considerations of reactivity controlled compression ignition particulate matter and presents new research highlighting the importance of injection strategy and fuel composition on reactivity controlled compression ignition particulate matter formation. Particle size measurements and the transmission electron microscopy results do show the presence of soot particles; however, the elemental carbon fraction was, in many cases, within the uncertainty of the thermal–optical measurement. Particulate matter emitted during reactivity controlled compression ignition operation was also collected with a novel sampling technique and analyzed by thermal desorption or pyrolysis gas chromatography mass spectroscopy. Particulate matter speciation results indicated that the high boiling range of diesel hydrocarbons was likely responsible for the particulate matter mass captured on the filter media. Finally, to investigate potential fuel chemistry effects, either ethanol or biodiesel were incorporated to assess whether oxygenated fuels may enhance particle emission reduction.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Storey, John Morse; Curran, Scott J.; Lewis, Samuel A.
Low-temperature compression ignition combustion can result in nearly smokeless combustion, as indicated by a smoke meter or other forms of soot measurement that rely on absorbance due to elemental carbon content. Highly premixed low-temperature combustion modes do not form particulate matter in the traditional pathways seen with conventional diesel combustion. Previous research into reactivity controlled compression ignition particulate matter has shown, despite a near zero smoke number, significant mass can be collected on filter media used for particulate matter certification measurement. In addition, particulate matter size distributions reveal that a fraction of the particles survive heated double-dilution conditions. This papermore » summarizes research completed at Oak Ridge National Laboratory to date on characterizing the nature, chemistry and aftertreatment considerations of reactivity controlled compression ignition particulate matter and presents new research highlighting the importance of injection strategy and fuel composition on reactivity controlled compression ignition particulate matter formation. Particle size measurements and the transmission electron microscopy results do show the presence of soot particles; however, the elemental carbon fraction was, in many cases, within the uncertainty of the thermal–optical measurement. Particulate matter emitted during reactivity controlled compression ignition operation was also collected with a novel sampling technique and analyzed by thermal desorption or pyrolysis gas chromatography mass spectroscopy. Particulate matter speciation results indicated that the high boiling range of diesel hydrocarbons was likely responsible for the particulate matter mass captured on the filter media. Finally, to investigate potential fuel chemistry effects, either ethanol or biodiesel were incorporated to assess whether oxygenated fuels may enhance particle emission reduction.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reed, James R., E-mail: rreed@lsuhsc.edu; Cruz, Albert Leo N. dela, E-mail: adelac2@tigers.lsu.edu; Lomnicki, Slawo M., E-mail: slomni1@lsu.edu
Combustion processes generate different types of particulate matter (PM) that can have deleterious effects on the pulmonary and cardiovascular systems. Environmentally persistent free radicals (EPFRs) represent a type of particulate matter that is generated after combustion of environmental wastes in the presence of redox-active metals and aromatic hydrocarbons. Cytochromes P450 (P450/CYP) are membrane-bound enzymes that are essential for the phase I metabolism of most lipophilic xenobiotics. The EPFR formed by chemisorption of 2-monochlorophenol to silica containing 5% copper oxide (MCP230) has been shown to generally inhibit the activities of different forms of P450s without affecting those of cytochrome P450 reductasemore » and heme oxygenase-1. The mechanism of inhibition of rat liver microsomal CYP2D2 and purified rabbit CYP2B4 by MCP230 has been shown previously to be noncompetitive with respect to substrate. In this study, MCP230 was shown to competitively inhibit metabolism of 7-benzyl-4-trifluoromethylcoumarin and 7-ethoxyresorufin by the purified, reconstituted rabbit CYP1A2. MCP230 is at least 5- and 50-fold more potent as an inhibitor of CYP1A2 than silica containing 5% copper oxide and silica, respectively. Thus, even though PM generally inhibit multiple forms of P450, PM interacts differently with the forms of P450 resulting in different mechanisms of inhibition. P450s function as oligomeric complexes within the membrane. We also determined the mechanism by which PM inhibited metabolism by the mixed CYP1A2–CYP2B4 complex and found that the mechanism was purely competitive suggesting that the CYP2B4 is dramatically inhibited when bound to CYP1A2. - Highlights: • Combustion of organic pollutants generates long-lived particulate radicals (EPFRs). • Particulate matter (PM) competitively inhibited CYP1A2 activity. • EPFRs were much more potent CYP1A2 inhibitors than other types of PM. • PM interacts differently with different forms of P450. • PM competitively inhibited metabolism by the mixed CYP1A2–CYP2B4 complex.« less
Techno-economic analysis of wood biomass boilers for the greenhouse industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chau, J.; Sowlati, T.; Sokhansanj, Shahabaddine
2009-01-01
The objective of this study is to perform a techno-economic analysis on a typical wood pellet and wood residue boiler for generation of heat to an average-sized greenhouse in British Columbia. The variables analyzed included greenhouse size and structure, boiler efficiency, fuel types, and source of carbon dioxide (CO2) for crop fertilization. The net present value (NPV) show that installing a wood pellet or a wood residue boiler to provide 40% of the annual heat demand is more economical than using a natural gas boiler to provide all the heat at a discount rate of 10%. For an assumed lifespanmore » of 25 years, a wood pellet boiler system could generate NPV of C$259,311 without electrostatic precipitator (ESP) and C$74,695 with ESP, respectively. While, installing a wood residue boiler with or without an ESP could provide NPV of C$919,922 or C$1,104,538, respectively. Using a wood biomass boiler could also eliminate over 3000 tonne CO2 equivalents of greenhouse gases annually. Wood biomass combustion generates more particulate matters than natural gas combustion. However, an advanced emission control system could significantly reduce particulate matters emission from wood biomass combustion which would bring the particulate emission to a relatively similar level as for natural gas.« less
Samek, Lucyna; Furman, Leszek; Mikrut, Magdalena; Regiel-Futyra, Anna; Macyk, Wojciech; Stochel, Grażyna; van Eldik, Rudi
2017-11-01
Submicron particulate matter containing particles with an aerodynamic diameter ≤1 μm (PM1) are not monitored continuously by Environmental Protection Agencies around the World and are seldom studied. Numerous studies have indicated that people exposed to ultrafine (≤100 nm), submicron and fine particulate matter containing particles with an aerodynamic diameter ≤2.5 μm (PM2.5), can suffer from respiratory track diseases, cardiovascular, immunological or heart diseases and others. Inorganic pollutants containing redox active transition metals and small gaseous molecules, are involved in the generation of reactive oxygen and reactive nitrogen species. Inhalation of this kind of particles can affect immune-toxicity. Environmental pollution may aggravate the course of autoimmune diseases, in particular influence the mechanisms of the autoimmune system. Important factors that influence the toxicity of particulate matter, are particle size distribution, composition and concentration. This report deals with the composition of PM1 and PM2.5 fractions collected in Krakow, Poland. In spring 2015, the mean concentrations of PM1 and PM2.5 were 19 ± 14 and 27 ± 19 μg/m 3 , respectively. The PM2.5 fraction contained approximately 70 ± 17% of submicron particulate matter. In spring 2016, the mean concentrations of PM1 and PM2.5 were 12 ± 5 and 22 ± 12 μg/m 3 , respectively. The PM2.5 fraction contained approximately 60 ± 15% of submicron particulate matter. The concentrations of the elements Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr and Pb in both fractions were determined by X-ray fluorescence spectrometry. Most of the analyzed metals had higher concentrations in the fine fraction than in the submicron one. Concentrations of V and As were below the detection limit in both fractions, whereas concentrations of Mn and Ca were below the detection limits in the PM1 fraction. The results are discussed in terms of the consequences they may have on the APARIC project presently underway in Krakow. Copyright © 2017 Elsevier Ltd. All rights reserved.
40 CFR 52.1880 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because the... matter in the Greater Metropolitan Cleveland Intrastate Region and the Ohio portions of the Northwest...
40 CFR 52.1880 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because the... matter in the Greater Metropolitan Cleveland Intrastate Region and the Ohio portions of the Northwest...
40 CFR 52.1880 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because the... matter in the Greater Metropolitan Cleveland Intrastate Region and the Ohio portions of the Northwest...
40 CFR 52.1880 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because the... matter in the Greater Metropolitan Cleveland Intrastate Region and the Ohio portions of the Northwest...
Code of Federal Regulations, 2014 CFR
2014-07-01
... previously approved in 40 CFR 52.223 is retained. (iii) The addition of Rule 209, Fossil Fuel-Steam Generator... CFR 52.223 are retained. (ii) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on July 22...) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on February 10, 1977, is disapproved and the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... previously approved in 40 CFR 52.223 is retained. (iii) The addition of Rule 209, Fossil Fuel-Steam Generator... CFR 52.223 are retained. (ii) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on July 22...) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on February 10, 1977, is disapproved and the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... previously approved in 40 CFR 52.223 is retained. (iii) The addition of Rule 209, Fossil Fuel-Steam Generator... CFR 52.223 are retained. (ii) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on July 22...) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on February 10, 1977, is disapproved and the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... previously approved in 40 CFR 52.223 is retained. (iii) The addition of Rule 209, Fossil Fuel-Steam Generator... CFR 52.223 are retained. (ii) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on July 22...) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on February 10, 1977, is disapproved and the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... previously approved in 40 CFR 52.223 is retained. (iii) The addition of Rule 209, Fossil Fuel-Steam Generator... CFR 52.223 are retained. (ii) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on July 22...) Rule 209, Fossil Fuel-Steam Generator Facility, submitted on February 10, 1977, is disapproved and the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
... Promulgation of Implementation Plans; Kentucky; Louisville; Fine Particulate Matter 2002 Base Year Emissions... action to approve the 1997 annual fine particulate matter (PM 2.5 ) 2002 base year emissions inventory... 45957
Lopez, Ramon; Farber, Mark O.; Wong, Vincent; Lacey, Steven E.
2016-01-01
Objective We conducted an exposure chamber study in humans using a simulated clinical procedure lasing porcine tissue to demonstrate evidence of effects of exposure to laser generated particulate matter (LGPM). Methods We measured pre- and post-exposure changes in exhaled nitric oxide (eNO), spirometry, heart rate variability (HRV), and blood markers of inflammation in five volunteers. Results Change in pre- and post-exposure measurements of eNO and spirometry were unremarkable. Neutrophil and lymphocyte counts increased and fibrinogen levels decreased in four of the five subjects. Measures of HRV showed decreases in the standard deviation of normal between beat intervals and sequential five-minute intervals. Conclusion These data represent the first evidence of human physiologic response to LGPM exposure. Further exploration of coagulation effects and HRV are warranted. PMID:27465102
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gunasekar, Palur G., E-mail: palur.gunasekar@wpafb.af.mil; Stanek, Lindsay W., E-mail: Stanek.Lindsay@epa.gov
2011-07-15
The 2009 Toxicology and Risk Assessment Conference (TRAC) session on 'Advances in Exposure and Toxicity Assessment of Particulate Matter' was held in April 2009 in West Chester, OH. The goal of this session was to bring together toxicology, geology and risk assessment experts from the Department of Defense and academia to examine issues in exposure assessment and report on recent epidemiological findings of health effects associated with particulate matter (PM) exposure. Important aspects of PM exposure research are to detect and monitor low levels of PM with various chemical compositions and to assess the health risks associated with these exposures.more » As part of the overall theme, some presenters discussed collection methods for sand and dust from Iraqi and Afghanistan regions, health issues among deployed personnel, and future directions for risk assessment research among these populations. The remaining speakers focused on the toxicity of ultrafine PM and the characterization of aerosols generated during ballistic impacts of tungsten heavy alloys.« less
Gunasekar, Palur G; Stanek, Lindsay W
2011-07-15
The 2009 Toxicology and Risk Assessment Conference (TRAC) session on "Advances in Exposure and Toxicity Assessment of Particulate Matter" was held in April 2009 in West Chester, OH. The goal of this session was to bring together toxicology, geology and risk assessment experts from the Department of Defense and academia to examine issues in exposure assessment and report on recent epidemiological findings of health effects associated with particulate matter (PM) exposure. Important aspects of PM exposure research are to detect and monitor low levels of PM with various chemical compositions and to assess the health risks associated with these exposures. As part of the overall theme, some presenters discussed collection methods for sand and dust from Iraqi and Afghanistan regions, health issues among deployed personnel, and future directions for risk assessment research among these populations. The remaining speakers focused on the toxicity of ultrafine PM and the characterization of aerosols generated during ballistic impacts of tungsten heavy alloys. Copyright © 2011 Elsevier Inc. All rights reserved.
Singh, Nahar; Ahuja, Tarushee; Ojha, Vijay Narain; Soni, Daya; Tripathy, S Swarupa; Leito, Ivo
2013-01-01
As a result of rapid industrialization several chemical forms of organic and inorganic mercury are constantly introduced to the environment and affect humans and animals directly. All forms of mercury have toxic effects; therefore accurate measurement of mercury is of prime importance especially in suspended particulate matter (SPM) collected through high volume sampler (HVS). In the quantification of mercury in SPM samples several steps are involved from sampling to final result. The quality, reliability and confidence level of the analyzed data depends upon the measurement uncertainty of the whole process. Evaluation of measurement uncertainty of results is one of the requirements of the standard ISO/IEC 17025:2005 (European Standard EN IS/ISO/IEC 17025:2005, issue1:1-28, 2006). In the presented study the uncertainty estimation in mercury determination in suspended particulate matter (SPM) has been carried out using cold vapor Atomic Absorption Spectrometer-Hydride Generator (AAS-HG) technique followed by wet chemical digestion process. For the calculation of uncertainty, we have considered many general potential sources of uncertainty. After the analysis of data of seven diverse sites of Delhi, it has been concluded that the mercury concentration varies from 1.59 ± 0.37 to 14.5 ± 2.9 ng/m(3) with 95% confidence level (k = 2).
EXPOSURE ASSESSMENT OF OLDER ADULTS TO PARTICULATE MATTER
The factors that influence the amount of particulate matter that potentially susceptible elderly Americans are exposed to is an issue of concern. This presentation and abstract investigates these factors using data obtained from three longitudinal particulate matter panel studies...
Concentrations of elemental carbon (EC), organic carbon matter (OM), particulate matter less than 2.5 um (PM2.5), and reconstructed soil, trace element oxides, and sulfate are reported from four locations near the World Trade Center (WTC) complex for airborne particulate matter (...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-02
... Matter AGENCY: Environmental Protection Agency (EPA). ACTION: Announcement of public hearings. SUMMARY... Standards for Particulate Matter,'' that is scheduled to be published in the Federal Register on June 29... standards (NAAQS) for particulate matter (PM) to provide requisite protection of public health and welfare...
Uchiyama, Shigehisa; Senoo, Yui; Hayashida, Hideki; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki
2016-01-01
We developed an analytical method for analyzing electronic cigarette (E-cigarette) smoke, and measured the carbonyl compounds and volatile organic compounds generated by 10 brands of second-generation E-cigarettes. A glass filter (Cambridge filter pad) for particulate matter and a solid sorbent tube packed with Carboxen-572 for gaseous compounds were used to collect E-cigarette smoke. These were then analyzed using a two-step elution method with carbon disulfide and methanol, followed by high-performance liquid chromatography (HPLC) and gas chromatography mass spectrometry (GC/MS). Formaldehyde (FA), acetaldehyde (AA), acetone (AC), acrolein (ACR), propanal (PA), acetol (AT), glyoxal (GO), and methyl glyoxal (MGO) were detected by HPLC in some E-cigarettes. Propylene glycol (PG), glycerol (GLY), and some esters were detected by GC/MS. GO and MGO exist mainly as particulate matter. AA, AC, ACR, PA, and AT exist mainly as gaseous compounds. FA exists as both particulate matter and gaseous compounds. These carbonyl compounds have carbon numbers C1 - C3. The main components of E-liquid are PG (C3) and GLY (C3). Therefore, the oxidation of liquids, such as PG and GLY in E-cigarettes upon incidental contact with the heating element in E-cigarette, is suggested as being a possible cause for carbonyl generation. When the puff number exceeds a critical point, carbonyl generation rapidly increases and then remains constant. The results of this study are now being used to determine the following E-cigarette smoking protocol: puff volume, 55 mL; puff duration, 2 s; and puff number, 30. E-cigarette analysis revealed very large variation in carbonyl concentration among not only different brands, but also different samples of the same product. Typical distributions of carbonyl concentration were not observed in any of the E-cigarettes tested, and the mean values greatly differed from median values.
Choi, Juwhan; Oh, Jee Youn; Lee, Young Seok; Min, Kyung Hoon; Hur, Gyu Young; Lee, Sung Yong; Kang, Kyung Ho; Shim, Jae Jeong
2018-01-01
Particulate matter and air pollution in Korea are becoming worse. There is a lack of research regarding the impact of particulate matter on patients with COPD. Therefore, the purpose of this study was to investigate the effects of various air pollution factors, including particulate matter, on the incidence rate of severe acute exacerbations of COPD (AECOPD) events. We analyzed the relationship between air pollutants and AECOPD events that required hospitalization at Guro Hospital in Korea from January 1, 2015 to May 31, 2017. We used general linear models with Poisson distribution and log-transformation to obtain adjusted relative risk (RR). We conducted further analysis through the Comprehensive Air-quality Index (CAI) that is used in Korea. Among various other air pollutants, particulate matter was identified as a major source of air pollution in Korea. When the CAI score was over 50, the incidence rate of severe AECOPD events was statistically significantly higher [RR 1.612, 95% CI, 1.065-2.440, P =0.024]. Additionally, the particulate matter levels 3 days before hospitalization were statistically significant [RR 1.003, 95% CI, 1.001-1.005, P =0.006]. Particulate matter and air pollution increase the incidence rate of severe AECOPD events. COPD patients should be cautioned against outdoor activities when particulate matter levels are high.
Burton, Kerrie A; Whitelaw, Jane L; Jones, Alison L; Davies, Brian
2016-07-01
Diesel engines have been a mainstay within many industries since the early 1900s. Exposure to diesel particulate matter (DPM) is a major issue in many industrial workplaces given the potential for serious health impacts to exposed workers; including the potential for lung cancer and adverse irritant and cardiovascular effects. Personal respiratory protective devices are an accepted safety measure to mitigate worker exposure against the potentially damaging health impacts of DPM. To be protective, they need to act as effective filters against carbon and other particulates. In Australia, the filtering efficiency of respiratory protective devices is determined by challenging test filter media with aerosolised sodium chloride to determine penetration at designated flow rates. The methodology outlined in AS/NZS1716 (Standards Australia International Ltd and Standards New Zealand 2012. Respiratory protective devices. Sydney/Wellington: SAI Global Limited/Standards New Zealand) does not account for the differences between characteristics of workplace contaminants like DPM and sodium chloride such as structure, composition, and particle size. This study examined filtering efficiency for three commonly used AS/NZS certified respirator filter models, challenging them with two types of diesel emissions; those from a diesel generator and a diesel engine. Penetration through the filter media of elemental carbon (EC), total carbon (TC), and total suspended particulate (TSP) was calculated. Results indicate that filtering efficiency assumed by P2 certification in Australia was achieved for two of the three respirator models for DPM generated using the small diesel generator, whilst when the larger diesel engine was used, filtering efficiency requirements were met for all three filter models. These results suggest that the testing methodology specified for certification of personal respiratory protective devices by Standards Australia may not ensure adequate protection for respirator users against DPM under all circumstances of diesel generated particles. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Zhang, Zhi-Dan; Xi, Ben-Ye; Cao, Zhi-Guo; Jia, Li-Ming
2014-08-01
Taking Populus tomentosa as an example, a methodology called elution-weighing-particle size-analysis (EWPA) was proposed to evaluate quantitatively the ability of retaining fine particulate matter (PM2.5, diameter d ≤ 2.5 μm) and atmospheric particulate matter by plant leaves using laser particle size analyzer and balance. This method achieved a direct, accurate measurement with superior operability about the quality and particle size distribution of atmospheric particulate matter retained by plant leaves. First, a pre-experiment was taken to test the stability of the method. After cleaning, centrifugation and drying, the particulate matter was collected and weighed, and then its particle size distribution was analyzed by laser particle size analyzer. Finally, the mass of particulate matter retained by unit area of leaf and stand was translated from the leaf area and leaf area index. This method was applied to a P. tomentosa stand which had not experienced rain for 27 days in Beijing Olympic Forest Park. The results showed that the average particle size of the atmospheric particulate matter retained by P. tomentosa was 17.8 μm, and the volume percentages of the retained PM2.5, inhalable particulate matter (PM10, d ≤ 10 μm) and total suspended particle (TSP, d ≤ 100 μm) were 13.7%, 47.2%, and 99.9%, respectively. The masses of PM2.5, PM10, TSP and total particulate matter were 8.88 x 10(-6), 30.6 x 10(-6), 64.7 x 10(-6) and 64.8 x 10(-6) g x cm(-2) respectively. The retention quantities of PM2.5, PM10, TSP and total particulate matter by the P. tomentosa stand were 0.963, 3.32, 7.01 and 7.02 kg x hm(-2), respectively.
Štrbová, Kristína; Raclavská, Helena; Bílek, Jiří
2017-12-01
The aim of the study was to characterize vertical distribution of particulate matter, in an area well known by highest air pollution levels in Europe. A balloon filled with helium with measuring instrumentation was used for vertical observation of air pollution over the fugitive sources in Moravian-Silesian metropolitan area during spring and summer. Synchronously, selected meteorological parameters were recorded together with particulate matter for exploration its relationship with particulate matter. Concentrations of particulate matter in the vertical profile were significantly higher in the spring than in the summer. Significant effect of fugitive sources was observed up to the altitude ∼255 m (∼45 m above ground) in both seasons. The presence of inversion layer was observed at the altitude ∼350 m (120-135 m above ground) at locations with major source traffic load. Both particulate matter concentrations and number of particles for the selected particle sizes decreased with increasing height. Strong correlation of particulate matter with meteorological parameters was not observed. The study represents the first attempt to assess the vertical profile over the fugitive emission sources - old environmental burdens in industrial region. Copyright © 2017 Elsevier Ltd. All rights reserved.
Estimation of particulate matter from simulation and measurements
NASA Astrophysics Data System (ADS)
Nakata, Makiko; Nakano, Tomio; Okuhara, Takaaki; Sano, Itaru; Mukai, Sonoyo
2011-11-01
The particulate matter is a typical indicator of small particles in the atmosphere. In addition to providing impacts on climate and environment, these small particles can bring adverse effects on human health. Then an accurate estimation of particulate matter is an urgent subject. We set up SPM sampler attached to our AERONET (Aerosol Robotics Network) station in urban city of Higashi-Osaka in Japan. The SPM sampler provides particle information about the concentrations of various SPMs (e.g., PM10 and PM2.5) separately. The AEROENT program is world wide ground based sunphotometric observation networks by NASA and provides the spectral information about aerosol optical thickness (AOT) and Angstrom exponent (α). Simultaneous measurements show that a linear correlation definitely exists between AOT and PM2.5. These results indicate that particulate matter can be estimated from AOT. However AOT represents integrated values of column aerosol amount retrieved from optical property, while particulate matter concentration presents in-situ aerosol loading on the surface. Then simple way using linear correlation brings the discrepancy between observed and estimated particulate matter. In this work, we use cluster information about aerosol type to reduce the discrepancy. Our improved method will be useful for retrieving particulate matter from satellite measurements.
NEW TECHNOLOGY FOR THE CONTROL OF AEROSOLS FROM STATIONARY SOURCES
The paper discusses an EPA program to develop new technologies for controlling particulate matter from stationary sources, including both electrostatically augmented fabric filtration (ESFF) and electrostatic precipitators (ESPs). The first generation ESFF system, using an electr...
Oh, Hyeon-Ju; Jeong, Na-Na; Chi, Woo-Bae; Seo, Ji-Hoon; Jun, Si-Moon; Sohn, Jong-Ryeul
2015-10-01
Particulate matter (PM) in buildings are mostly sourced from the transport of outdoor particles through a heating, ventilation, and air conditioning (HVAC) system and generation of particle within the building itself. We investigated the concentrations and characteristic of indoor and outdoor particles and airborne bacteria concentrations across four floors of a building located in a high-traffic area. In all the floors we studied (first, second, fifth, and eighth), the average concentrations of particles less than 10 μm (PM10) in winter for were higher than those in summer. On average, a seasonal variation in the PM10 level was found for the first, fifth, and eighth floors, such that higher values occurred in the winter season, compared to the summer season. In addition, in winter, the indoor concentrations of PM10 on the first, fifth, and eighth floors were higher than those of the outdoor PM10. The maximum level of airborne bacteria concentration was found in a fifth floor office, which held a private academy school consisting of many students. Results indicated that the airborne bacteria remained at their highest concentration throughout the weekday period and varied by students' activity. The correlation coefficient (R (2)) and slope of linear approximation for the concentrations of particulate matter were used to evaluate the relationship between the indoor and outdoor particulate matter. These results can be used to predict both the indoor particle levels and the risk of personal exposure to airborne bacteria.
NASA Astrophysics Data System (ADS)
Lau, Maximilian Peter; Sander, Michael; Gelbrecht, Jörg; Hupfer, Michael
2014-05-01
Microbial respiration is a key driver of element cycling in oxic and anoxic environments. Upon depletion of oxygen as terminal electron acceptor (TEA), a number of anaerobic bacteria can employ alternative TEA for intracellular energy generation. Redox active quinone moieties in dissolved organic matter (DOM) are well known electron acceptors for microbial respiration. However, it remains unclear whether quinones in adsorbed and particulate OM accept electrons in a same way. In our studies we aim to understand the importance of natural organic matter (NOM) as electron acceptors for microbial energy gain and its possible implications for methanogenesis. Using a novel electrochemical approach, mediated electrochemical reduction and -oxidation, we can directly quantify reduced hydroquinone and oxidized quionone moieties in dissolved and particulate NOM samples. In a mesocosm experiment, we rewetted sediment and peat soil and followed electron transfer to the inorganic and organic electron acceptors over time. We found that inorganic and organic electron acceptor pools were depleted over the same timescales. More importantly, we showed that organic, NOM-associated electron accepting moieties represent as much as 21 40% of total TEA inventories. These findings support earlier studies that propose that the reduction of quinone moieties in particulate organic matter competitively suppresses methanogenesis in wetland soils. Our results indicate that electron transfer to organic, particulate TEA in inundated ecosystems has to be accounted for when establishing carbon budgets in and projecting greenhouse gas emissions from these systems.
Measurement and analysis of ambient atmospheric particulate matter in urban and remote environments
NASA Astrophysics Data System (ADS)
Hagler, Gayle S. W.
Atmospheric particulate matter pollution is a challenging environmental concern in both urban and remote locations worldwide. It is intrinsically difficult to control, given numerous anthropogenic and natural sources (e.g. fossil fuel combustion, biomass burning, dust, and seaspray) and atmospheric transport up to thousands of kilometers after production. In urban regions, fine particulate matter (particles with diameters under 2.5 mum) is of special concern for its ability to penetrate the human respiratory system and threaten cardiopulmonary health. A second major impact area is climate, with particulate matter altering Earth's radiative balance through scattering and absorbing solar radiation, modifying cloud properties, and reducing surface reflectivity after deposition in snow-covered regions. While atmospheric particulate matter has been generally well-characterized in populated areas of developed countries, particulate pollution in developing nations and remote regions is relatively unexplored. This thesis characterizes atmospheric particulate matter in locations that represent the extreme ends of the spectrum in terms of air pollution-the rapidly-developing and heavily populated Pearl River Delta Region of China, the pristine and climate-sensitive Greenland Ice Sheet, and a remote site in the Colorado Rocky Mountains. In China, fine particles were studied through a year-long field campaign at seven sites surrounding the Pearl River Delta. Fine particulate matter was analyzed for chemical composition, regional variation, and meteorological impacts. On the Greenland Ice Sheet and in the Colorado Rocky Mountains, the carbonaceous fraction (organic and elemental carbon) of particulate matter was studied in the atmosphere and snow pack. Analyses included quantifying particulate chemical and optical properties, assessing atmospheric transport, and evaluating post-depositional processing of carbonaceous species in snow.
This presentation reviews the status and progress in forecasting particulate matter distributions. The shortcomings in representation of particulate matter formation in current atmospheric chemistry/transport models are presented based on analyses and detailed comparisons with me...
Numerous epidemiological studies have found associations between airborne particulate matter measured at community monitors and increased mortality and morbidity. Chemical and physical characteristics of particulate matter (e.g., elemental composition, size) and source identifi...
40 CFR 52.2429 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.477 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.477 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.1081 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...
40 CFR 52.2429 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.1131 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March 30...
40 CFR 52.1131 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March 30...
40 CFR 52.477 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.1081 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...
40 CFR 52.2429 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.1131 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March 30...
40 CFR 52.477 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.1081 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...
40 CFR 52.1081 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...
40 CFR 52.2429 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.1081 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1081 Section 52.1081 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Determination of Attainment. EPA has determined, as of January...
40 CFR 52.2429 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.2429 Section 52.2429 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 52.477 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.477 Section 52.477 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January 12...
40 CFR 60.282a - Standard for filterable particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... matter. 60.282a Section 60.282a Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... 23, 2013 § 60.282a Standard for filterable particulate matter. (a) On and after the date on which the... furnace any gases which: (i) Contain filterable particulate matter in excess of 0.10 gram per dry standard...
Karelin, A O; Lomtev, A Yu; Mozzhukhina, N A; Yeremin, G B; Nikonov, V A
Inhalation of fine particulate matters (PM and PM ) poses a threat for the health of population. Purpose of the study the analysis of the monitoring of fine particulate matters in the atmospheric air of Saint-Petersburg and identification of the main problems of the monitoring. Research methods methods of scientific hypothetical deductive cognition, sanitary-statistical methods, general logical methods and approaches of researches: analysis, synthesis, abstracting, generalization, induction. Results. The article represents the analysis of the monitoring of fine particulate matters in the atmospheric air of Saint- Petersburg. Only 11 in automatic monitoring stations out of 22 there is carried out the control of fine particulate matters: in 7 - PM and PM, and in 4 - PM The average year concentrations were below MAC in all the stations. The maximum concentrations achieved 3 MAC, but the repeatance of cases of exceedence of concentrations more than MAC was very rare. On the average of the city concentrations of PM were decreased from 0,8 MAC in 2006 and 1,1 MAC in 2007 to 0,5 MAC in 2013-14. The executed analysis revealed main problems of the monitoring of fine particulate matters in the Russian Federation. They include the absence of the usage 1of the officially approved methods of controlling of PM and PM in the atmospheric air until March 1, 2016, lack of the modern equipment for measurement of fine particulate matters. Conclusions. Therefore, the state of the monitoring of fine particulate matters in the atmospheric air in the Russian Federation fails to be satisfactory. It is necessary to improve system of the monitoring, create modern Russian appliances, methods and means for measurement of fine particulate matters concentrations in the atmospheric air.
NASA Astrophysics Data System (ADS)
Greene, N. A.; Morris, D. R.
2004-05-01
The District of Columbia has one of the greatest health disparities of cancer in the nation and ranks seventh highest as one of the unhealthiest places to live due to poor air quality (EPA Report, 1999). Also, a 1999 report from the Centers for Disease Control stated that the District had the highest overall rate of cancer incidence in the nation. Particulate matter is one of the major contributors to pollution in the environment. Quite often particulate matter is composed of toxic materials including heavy metals, pesticides, and spores. In some cases, the heavy metal particulates are considered carcinogenic. They are typically characterized as particles with diameters smaller than 1 m and are easily deposited into the alveolar regions of the human lungs, which can impose threatening health risks. In this study, I will design and execute an environmental exposure assessment for PM2.5, PM10, and heavy metals like chromium, as well as lead, cadmium and arsenic, in four observed wards of Washington, DC. Most interestingly, spatial distributions of both aerosols and heavy metals will be characterized as a function of size and mass properties. This will formulate a limited climatology of both types of particulate matter and selected heavy metals for specific regions within the District of Columbia. This dataset will further be related to epidemiological data and health outcomes for the observed areas of study. The essence of this study lies in its notoriety as the first to generate a dataset that focuses on toxic air pollutants in particular wards and may be utilized in various aspects of public health.
40 CFR 60.285a - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... performance test. (b) The owner or operator must determine compliance with the filterable particulate matter... used to determine the filterable particulate matter concentration. The sampling time and sample volume... repeat performance tests for filterable particulate matter at intervals no longer than 5 years following...
FEDERAL REFERENCE AND EQUIVALENT METHODS FOR MEASURING FINE PARTICULATE MATTER
In the national ambient air quality standards specified by the U.S. Environmental Protection Agency in the Code of Federal Regulations, new standards were established for particulate matter on July 18, 1997. The new particulate matter standards specify mass concentration as the...
Exposure to particulate matter air pollution has been causally linked to cardiovascular disease in humans. Several broad and overlapping hypotheses describing the biological mechanisms by which particulate matter exposure leads to cardiovascular disease and cardiac dysfunction ha...
Ambient particulate matter accelerates coagulation via an IL-6-dependent pathway
The mechanisms by which exposure to particulate matter increases the risk of cardiovascular events are not known. Recent human and animal data suggest that particulate matter may induce alterations in hemostatic factors. In this study we determined the mechanisms by which particu...
EXPOSURE ASSESSMENT FROM THE NERL RESEARCH TRIANGLE PARK PARTICULATE MATTER PANEL STUDY
The U.S. Environmental Protection Agency performed a particulate matter (PM) exposure assessment based on data from the National Exposure Research Laboratory (NERL) Research Triangle Park (RTP) Particulate Matter (PM) Panel Study. This study was a one-year investigation of PM ...
40 CFR 52.2526 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...
40 CFR 52.1374 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...
40 CFR 52.1025 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification to...
40 CFR 52.1374 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...
40 CFR 52.1374 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...
40 CFR 52.1341 - Control strategy: particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: particulate matter. 52.1341 Section 52.1341 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: particulate matter. Determination of Attainment. EPA has determined, as of May 23, 2011...
40 CFR 52.2526 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...
40 CFR 52.1025 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification to...
40 CFR 52.2526 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...
40 CFR 52.2526 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...
40 CFR 52.1374 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...
40 CFR 52.1374 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted minor...
40 CFR 52.1025 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification to...
40 CFR 52.1341 - Control strategy: particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: particulate matter. 52.1341 Section 52.1341 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: particulate matter. Determination of Attainment. EPA has determined, as of May 23, 2011...
40 CFR 52.1025 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification to...
40 CFR 52.2526 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.2526 Section 52.2526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal for...
Researchers at the U.S. Environmental Protection Agency's (EPA's) Office of Research and
Development (ORD) have conducted a series of tests to characterize the size and composition of primary particulate matter (PM) generated from the combustion of heavy fuel oil and pulverize...
Exposure to Air Pollution Enhances the Generation of Vascular Microparticles
Epidemiological studies associate exposure to ambient levels of particulate matter (PM) with cardiovascular morbidity and mortality. The biological mechanisms by which PM exposure induces cardiovascular effects remain to be elucidated. One important limitation is the lack of sens...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-23
.... Visibility impairment is primarily caused by fine particulate matter (PM 2.5 ) or secondary aerosol formed in.... 70 FR 39104. In making a BART applicability determination for a fossil fuel-fired electric generating...
30 CFR 57.5066 - Maintenance standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Physical Agents, and Diesel Particulate Matter Diesel Particulate Matter-Underground Only § 57.5066... manufacturer specifications; and (3) The operator must maintain any emission or particulate control device...
30 CFR 57.5066 - Maintenance standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Physical Agents, and Diesel Particulate Matter Diesel Particulate Matter-Underground Only § 57.5066... manufacturer specifications; and (3) The operator must maintain any emission or particulate control device...
Extensive research has been conducted on effects resulting from exposure to ambient particulate matter. Particulate matter has been linked to cardiovascular diseases, respiratory problems, and reproductive effects. A large body of work on particulate matter focuses on atmospher...
40 CFR 60.2720 - May I conduct performance testing less often?
Code of Federal Regulations, 2010 CFR
2010-07-01
... least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen chloride, or...) If your CISWI unit continues to meet the emission limitation for particulate matter, hydrogen... shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or opacity, you...
40 CFR 52.427 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.427 Section 52.427 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. Determination of attainment. EPA has determined, as of May 16, 2012, that based on 2007 to...
40 CFR 52.332 - Control strategy: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...
40 CFR 52.332 - Control strategy: Particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...
40 CFR 52.332 - Control strategy: Particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...
40 CFR 52.332 - Control strategy: Particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-09
... and 2006 Fine Particulate Matter National Ambient Air Quality Standards AGENCY: Environmental...-hour fine particulate matter (PM 2.5 ) national ambient air quality standards (NAAQS). Section 110(a..., Incorporation by reference, Intergovernmental relations, Nitrogen dioxide, Particulate matter, Reporting and...
40 CFR 52.332 - Control strategy: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.332 Section 52.332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10 nonattainment...
40 CFR 52.2678 - Control strategy and regulations: Particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy and regulations: Particulate matter. 52.2678 Section 52.2678 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....2678 Control strategy and regulations: Particulate matter. (a) The requirements of § 51.110(a) and...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-01
... 2006 Fine Particulate Matter National Ambient Air Quality Standards AGENCY: Environmental Protection... 24-hour fine particulate matter (PM 2.5 ) national ambient air quality standards (NAAQS). Section 110..., Incorporation by reference, Intergovernmental relations, Nitrogen dioxide, Particulate matter, Reporting and...
40 CFR 52.2678 - Control strategy and regulations: Particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy and regulations: Particulate matter. 52.2678 Section 52.2678 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....2678 Control strategy and regulations: Particulate matter. (a) The requirements of § 51.110(a) and...
SUMMARY FINDINGS FROM THE U.S. EPA'S PARTICULATE MATTER PANEL STUDIES
The U.S. EPA's Particulate Matter Panel Studies were a series of longitudinal human exposure studies used to characterize personal exposures to particulate matter (PM) and related co-pollutants to that of pollutants of ambient origin. Participants were monitored over time (28 d...
Impact of climatic extremity upon human health
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miah, M.A.; Samad, M.A.
The extreme climate generated in the wake of the shortage of the supply of natural water in the lower Ganges basin has triggered a number of environmental diseases in the lower Ganges basin. In the wake of improper sanitation conditions for the scarcity of water, water-borne diseases like cholera, diarrhea, hepatitis, etc., break out and take out the lives of victims. Further, the development of the dry climate has favored an increased amount of suspended particulate matter in the air. The result is the prevalent problem of asthma which is even worse than the water-borne diseases. Almost one in everymore » four families living in this city has an asthma patient. The worst is that more than 10% of the families have three asthma patients. And, most of the elderly asthma patients suffer from diabetes and high blood pressure at the same time. The wide spread of asthma is thought to be related to the triggering allergic action suffered by patients due to the presence of excess particulate matter in the air. More than 50% of the population suffer from nasal allergy, sinusitis, and chronic bronchitis. The suspended particles are mostly fine grains of sands and carbon. The cleanest air (usually, after a heavy rainfall) contains at least one gm of particulate matter in every 2,039 cubic meter of air. An average man will inhale about 1.11 million gallons of air per year which amounts to about 2 gm of particulate matter per year. Additionally, during the dry months, major duststorms appear a couple of times with an uplift of half a million kg of dust in air over about 810 square km each time. The paper will focus on water scarcity, the climatic extremity, suspended particulate matter, the outbreaks of water-borne and the prevalent respiratory diseases, and suggestions to mitigate human sufferings.« less
Peiris, R H; Jaklewicz, M; Budman, H; Legge, R L; Moresoli, C
2013-06-15
Fluorescence excitation-emission matrix (EEM) approach together with principal component analysis (PCA) was used for assessing hydraulically irreversible fouling of three pilot-scale ultrafiltration (UF) systems containing full-scale and bench-scale hollow fiber membrane modules in drinking water treatment. These systems were operated for at least three months with extensive cycles of permeation, combination of back-pulsing and scouring and chemical cleaning. The principal component (PC) scores generated from the PCA of the fluorescence EEMs were found to be related to humic substances (HS), protein-like and colloidal/particulate matter content. PC scores of HS- and protein-like matter of the UF feed water, when considered separately, showed reasonably good correlations with the rate of hydraulically irreversible fouling for long-term UF operations. In contrast, comparatively weaker correlations for PC scores of colloidal/particulate matter and the rate of hydraulically irreversible fouling were obtained for all UF systems. Since, individual correlations could not fully explain the evolution of the rate of irreversible fouling, multi-linear regression models were developed to relate the combined effect of HS-like, protein-like and colloidal/particulate matter PC scores to the rate of hydraulically irreversible fouling for each specific UF system. These multi-linear regression models revealed significant individual and combined contribution of HS- and protein-like matter to the rate of hydraulically irreversible fouling, with protein-like matter generally showing the greatest contribution. The contribution of colloidal/particulate matter to the rate of hydraulically irreversible fouling was not as significant. The addition of polyaluminum chloride, as coagulant, to UF feed appeared to have a positive impact in reducing hydraulically irreversible fouling by these constituents. The proposed approach has applications in quantifying the individual and synergistic contribution of major natural water constituents to the rate of hydraulically irreversible membrane fouling and shows potential for controlling UF irreversible fouling in the production of drinking water. Copyright © 2013 Elsevier Ltd. All rights reserved.
40 CFR Table 7 to Subpart Ddddd of... - Establishing Operating Limits
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Particulate matter, mercury, or total selected metals a. Wet scrubber operating parameters i. Establish a site... drop and liquid flow rate monitors and the particulate matter, mercury, or total selected metals... from the pressure drop and liquid flow rate monitors and the particulate matter, mercury, or total...
A microscale emission factor model (MicroFacPM) for predicting real-time site-specific motor vehicle particulate matter emissions was presented in the companion paper entitled "Development of a Microscale Emission Factor Model for Particulate Matter (MicroFacPM) for Predicting Re...
40 CFR 52.275 - Particulate matter control.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Particulate matter control. 52.275 Section 52.275 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.275 Particulate matter control. (a) The following rules or portions of rules...
40 CFR 52.275 - Particulate matter control.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Particulate matter control. 52.275 Section 52.275 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.275 Particulate matter control. (a) The following rules or portions of rules...
40 CFR 52.275 - Particulate matter control.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Particulate matter control. 52.275 Section 52.275 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.275 Particulate matter control. (a) The following rules or portions of rules...
40 CFR 52.275 - Particulate matter control.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Particulate matter control. 52.275 Section 52.275 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.275 Particulate matter control. (a) The following rules or portions of rules...
USDA-ARS?s Scientific Manuscript database
Particulate Matter (PM) emissions from animal operations have been identified as a major air pollutant source with health and environmental impacts. Nearly 600 million broilers are produced annually on the Delmarva Peninsula, making it a hot spot for particulate matter emissions from poultry houses....
40 CFR 60.472 - Standards for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.472 Standards for particulate matter. (a) On and after the...) Particulate matter in excess of: (i) 0.04 kg/Mg (0.08 lb/ton) of asphalt shingle or mineral-surfaced roll...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-08
... and 2006 Fine Particulate Matter National Ambient Air Quality Standards AGENCY: Environmental...) requirements for the 1997 annual and 2006 24-hour fine particulate matter (PM 2.5 ) National Ambient Air..., Incorporation by reference, Nitrogen dioxide, Particulate Matter, Reporting and recordkeeping requirements...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-01
... Review of the National Ambient Air Quality Standards for Particulate Matter AGENCY: Environmental... Review of the Particulate Matter National Ambient Air Quality Standards--First External Review Draft (75... Particulate Matter National Ambient Air Quality Standards--First External Review Draft (March 2010), please...
40 CFR 52.634 - Particulate matter (PM-10) Group III SIP.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Particulate matter (PM-10) Group III SIP. 52.634 Section 52.634 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Hawaii § 52.634 Particulate matter...
40 CFR 52.146 - Particulate matter (PM-10) Group II SIP commitments.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Particulate matter (PM-10) Group II SIP commitments. 52.146 Section 52.146 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Arizona § 52.146 Particulate matter...
GENETIC INFLUENCES ON IN VITRO PARTICULATE MATTER-INDUCED AIRWAY EPITHELIAL INJURY AND INFLAMMATORY MEDIATOR RELEASE.
JA Dye, JH Richards, DA Andrews, UP Kodavanti. US EPA, RTP, NC, USA.
Particulate matter (PM) air pollution is capable of damaging the airway epitheli...
In response to epidemiological studies published over twenty years ago, at least three research communities have been intensively studying airborne particulate matter (PM). These efforts have been coordinated by approaching the source - atmospheric accumulation/receptor - exposu...
40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...
40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. In a letter dated January 30...
40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...
40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...
40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...
40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. In a letter dated January 30...
40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. (a) In a letter dated January 30...
40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...
40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...
40 CFR 52.933 - Control Strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.933 Section 52.933 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. (a) In a letter dated March 27, 1987, the Kentucky...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., hydrocarbon, and particulate matter exhaust emission standards. 89.112 Section 89.112 Protection of....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., hydrocarbon, and particulate matter exhaust emission standards. 89.112 Section 89.112 Protection of....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-25
... Promulgation of Implementation Plans; Kentucky; Louisville; Fine Particulate Matter 2002 Base Year Emissions... approve the fine particulate matter (PM 2.5 ) 2002 base year emissions inventory, portion of the State...), a reasonable further progress (RFP) plan, contingency measures, a 2002 base year emissions inventory...
40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. In a letter dated January 30...
40 CFR 52.2231 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2231 Section 52.2231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2231 Control strategy: Sulfur oxides and particulate matter. (a) Part D conditional approval. The...
40 CFR 52.1781 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1781 Section 52.1781 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.1781 Control strategy: Sulfur oxides and particulate matter. (a) The plan's control strategy...
40 CFR 52.1278 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1278 Section 52.1278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Mississippi § 52.1278 Control strategy: Sulfur oxides and particulate matter. (a) In a letter dated January 30...
40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.578 Section 52.578 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 26, 1987, the Georgia Department of...
40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...
40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.578 Section 52.578 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 26, 1987, the Georgia Department of...
40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.578 Section 52.578 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 26, 1987, the Georgia Department of...
40 CFR 52.933 - Control Strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.933 Section 52.933 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 27, 1987, the Kentucky Department...
40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...
40 CFR 52.62 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.62 Section 52.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... strategy: Sulfur oxides and particulate matter. In a letter dated May 29, 1987, the Alabama Department of...
40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control Strategy: Sulfur oxides and particulate matter. 52.578 Section 52.578 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Strategy: Sulfur oxides and particulate matter. In a letter dated March 26, 1987, the Georgia Department of...
40 CFR 52.2130 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.2130 Section 52.2130 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.2130 Control strategy: Sulfur oxides and particulate matter. In letters dated May 7, and...
40 CFR 52.1781 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and particulate matter. 52.1781 Section 52.1781 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carolina § 52.1781 Control strategy: Sulfur oxides and particulate matter. (a) The plan's control strategy...
30 CFR 57.5060 - Limit on exposure to diesel particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent... particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift... mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350...
30 CFR 57.5060 - Limit on exposure to diesel particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent... particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift... mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350...
30 CFR 57.5060 - Limit on exposure to diesel particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent... particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift... mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350...
30 CFR 57.5060 - Limit on exposure to diesel particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent... particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift... mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-19
... Promulgation of Air Quality Implementation Plans; Indiana; Particulate Matter Ambient Air Quality Standards... revise the Indiana State Implementation Plan (SIP) for particulate matter under the Clean Air Act. This submission contains the 24-hour fine particle National Ambient Air Quality Standards (NAAQS) promulgated by...
Characterization of functional groups of airborne particulate matter
NASA Astrophysics Data System (ADS)
Baitimirova, M.; Katkevics, J.; Baumane, L.; Bakis, E.; Viksna, A.
2013-12-01
Particulate matter of organic combustibles burning consists of various hydrocarbons and radicals, which may cause harmful impact to human health. In this study solid particulate matter were collected on the filters from burning of various combustibles in a burning chamber and from atmosphere of city of Riga by dichotomous impactor. FTIR spectra were obtained before and after samples' treatment. Absorptions associated with aliphatic and aromatic hydrocarbons and alcohol functional groups were observed in the FTIR spectra. Free radicals of particulate matter were detected by electron paramagnetic resonance (EPR).
Association between ambient particulate matter and disorders of vestibular function.
Han, Changwoo; Lim, Youn-Hee; Jung, Kweon; Hong, Yun-Chul
2017-05-01
Exposure to environmental chemicals has been suggested to alter the physiologic state of the inner and middle ear. However, it is unknown if particulate matter exposure is associated with acute vestibular dysfunction. To estimate the effects of particulate matter exposure on the number of hospital visits related to three major diseases of vestibular dysfunction, Meniere's disease (MD), benign paroxysmal positional vertigo (BPPV), and vestibular neuronitis (VN). Our study subject is from Korean National Health Insurance Service-National Sample Cohort, which is dynamic cohort consist of 1 million participants representing the Korean population. Among total cohort participants, we used the hospital visit data of 210,000 individuals who resided in Seoul from 2007 to 2010. Time series analysis using the Poisson generalized additive model and case-crossover analysis using conditional logistic regression were used to investigate the association between daily particulate matter levels (PM 2.5 , particulate matter <2.5μg/m 3 ; PM 10 , particulate matter <10μg/m 3 ; PM 10-2.5 , PM 10 - PM 2.5 ) and number of MD, BPPV, and VN hospital visits. Time series analysis showed that an interquartile range (IQR) increase in PM 10 and PM 10-2.5 on lag day 1 was associated with an increased risk of MD hospital visits [relative risk (RR), 95% confidence interval (CI), PM 10 : 1.09 (1.02-1.15); PM 10-2.5 : 1.06 (1.02-1.10)]. In addition, elderly individuals (≥60 years old) showed an increased risk of MD hospital visits after particulate matter exposure when compared to younger individuals. An IQR increase in particulate matter on lag day 1 was associated with a marginally significant increase in VN hospital visits [RR (95%CI), PM 2.5 : 1.11 (0.98-1.25); PM 10 : 1.07 (0.99-1.15); PM 10-2.5 : 1.04 (0.99-1.09)]. However, no association between particulate matter exposure and BPPV hospital visits was noted. Case-crossover analyses showed similar results to the time-series analysis across all three diseases. MD hospital visits were associated with ambient particulate matter exposure. Elderly individuals, in particular, were more susceptible to particulate matter exposure than younger individuals. Copyright © 2017 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Ammonia, greenhouse gases, and other emissions (e.g., particulate matter, volatile organic compounds, hydrogen sulfide) from livestock production systems are being increasingly scrutinized by regulatory agencies. These pollutants, which are also generated by energy, industrial, and transportation se...
Electrically heated particulate filter propagation support methods and systems
Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI
2011-06-07
A control system that controls regeneration of a particulate filter is provided. The system generally includes a regeneration module that controls current to the particulate filter to initiate combustion of particulate matter in the particulate filter. A propagation module estimates a propagation status of the combustion of the particulate matter based on a combustion temperature. A temperature adjustment module controls the combustion temperature by selectively increasing a temperature of exhaust that passes through the particulate filter.
McDonald-Buller, Elena; Kimura, Yosuke; Craig, Michael; McGaughey, Gary; Allen, David; Webster, Mort
2016-02-02
Cap and trade programs have historically been designed to achieve annual or seasonal reductions in emissions of nitrogen oxides and sulfur dioxide from power plants. Emissions reductions may not be temporally coincident with meteorological conditions conducive to the formation of peak ozone and fine particulate matter concentrations. Integrated power system and air quality modeling methods were developed to evaluate time-differentiated emissions price signals on high ozone days in the Mid-Atlantic portion of the Pennsylvania-New Jersey-Maryland (PJM) Interconnection and Electric Reliability Council of Texas (ERCOT) grids. Sufficient flexibility exists in the two grids with marked differences in demand and fuel generation mix to accommodate time-differentiated emissions pricing alone or in combination with a season-wide program. System-wide emissions reductions and production costs from time-differentiated pricing are shown to be competitive with those of a season-wide program on high ozone days and would be more cost-effective if the primary policy goal was to target emissions reductions on these days. Time-differentiated pricing layered as a complement to the Cross-State Air Pollution Rule had particularly pronounced benefits for the Mid-Atlantic PJM system that relies heavily on coal-fired generation. Time-differentiated pricing aimed at reducing ozone concentrations had particulate matter reduction co-benefits, but if particulate matter reductions are the primary objective, other approaches to time-differentiated pricing may lead to greater benefits.
Introduction
An exposure assessment study was conducted in Atlanta, GA during fall 1999 and spring 2000 to examine the short-term effects of exposure to particulate matter and gaseous air pollutants on heart rate variability (HRV). Characterization of particulate matter (PM...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-09
... requirement for inclusion of condensable emissions of particulate matter (condensables) within the definition of ``regulated new source review (NSR) pollutant'' for fine particulate matter (PM 2.5 ) and particulate matter emissions less than or equal to ten micrometers in diameter (PM 10 ). In addition, because...
The NERL Particulate Matter Longitudinal Panel Studies were used to characterize temporal variations of personal exposure to PM and related co-pollutants, including that of PM measured at ambient sites. These studies were fundamental in understanding the associations between p...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-08
..., Quantitative Health Risk Assessment for Particulate Matter and Particulate Matter Urban-Focused Visibility Assessment. These two documents describe the quantitative analyses that have been conducted as part of the..., Quantitative Health Risk Assessment for Particulate Matter, please contact Dr. Zachary Pekar, Office of Air...
Under Project No. WP-1538 of the Strategic Environmental Research and Development Program, the U. S. Air Force's Arnold Engineering Development Center (AEDC) is developing an interim test method for non-volatile particulate matter (PM) specifically for the Joint Strike Fighter (J...
The Particulate Nature of Matter in Science Education and in Science.
ERIC Educational Resources Information Center
Vos, Wobbe de; Verdonk, Adri H.
1996-01-01
Discusses ideas about the particulate nature of matter and assesses the extent to which these represent a compromise between scientific and educational considerations. Analyzes relations between the particulate nature of matter in science and science education in an attempt to understand children's inclination to attribute all kinds of macroscopic…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-27
... ENVIRONMENTAL PROTECTION AGENCY [EPA-R10-OAR-2010-1914; FRL-9664-7] Adequacy Status of the Eagle River, Alaska Particulate Matter Limited Maintenance Plan for Transportation Conformity Purposes AGENCY... notifying the public of its finding that the Eagle River, Alaska, Particulate Matter (PM 10 ) Limited...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-12
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 52 [EPA-R04-OAR-2011-0849-201153(b); FRL-9617-3] Approval and Promulgation of Implementation Plans; Georgia; Rome; Fine Particulate Matter 2002 Emissions... approve the fine particulate matter (PM 2.5 ) 2002 base year emissions inventory portion of the State...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-20
... Promulgation of Implementation Plans; State of Missouri; Restriction of Emission of Particulate Matter From...) submitted March 17, 2011. This revision will amend the rule restricting emissions of particulate matter from... amendments to rule 10 CSR 10-6.400 Restriction of Emission of Particulate Matter from Industrial Processes...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-06
... ENVIRONMENTAL PROTECTION AGENCY [EPA-R05-OAR-2008-0398; FRL-9145-9] Adequacy Status of the Indianapolis, Indiana Submitted Annual Fine Particulate Matter Attainment Demonstration for Transportation... (MVEBs) for fine particulate matter (PM 2.5 ) and oxides of nitrogen (NOx) as a precursor to PM 2.5 in...
40 CFR 60.42Da - Standard for particulate matter (PM).
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for particulate matter (PM). 60.42Da Section 60.42Da Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR....42Da Standard for particulate matter (PM). (a) On and after the date on which the initial performance...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-02
... Deterioration and Nonattainment New Source Review; Fine Particulate Matter (PM2.5) AGENCY: Environmental... preconstruction permitting requirements for fine particulate matter (PM 2.5 ) into the Delaware SIP. In addition... fine particulate matter (PM 2.5 ) into the Delaware SIP. In addition, EPA proposed approval of SIP...
40 CFR 52.2306 - Particulate Matter (PM10) Group II SIP commitments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Particulate Matter (PM10) Group II SIP commitments. 52.2306 Section 52.2306 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Particulate Matter (PM10) Group II SIP commitments. On July 18, 1988, the Governor of Texas submitted a...
40 CFR 52.2306 - Particulate Matter (PM10) Group II SIP commitments.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Particulate Matter (PM10) Group II SIP commitments. 52.2306 Section 52.2306 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Particulate Matter (PM10) Group II SIP commitments. On July 18, 1988, the Governor of Texas submitted a...
40 CFR 60.42Da - Standard for particulate matter (PM).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for particulate matter (PM). 60.42Da Section 60.42Da Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR....42Da Standard for particulate matter (PM). (a) On and after the date on which the initial performance...
40 CFR 52.1637 - Particulate Matter (PM10) Group II SIP commitments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Particulate Matter (PM10) Group II SIP commitments. 52.1637 Section 52.1637 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Particulate Matter (PM10) Group II SIP commitments. (a) On August 19, 1988, the Governor of New Mexico...
77 FR 63234 - Approval and Promulgation of Implementation Plans; North Carolina 110(a)(1) and (2...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-16
... and 2006 Fine Particulate Matter National Ambient Air Quality Standards AGENCY: Environmental... SIP addresses emissions of particulate matter generally, and does not distinguish between PM 10 and PM 2.5. The Commenter also references the particulate matter maximum emission rates for two coal-fired...
40 CFR 52.1637 - Particulate Matter (PM10) Group II SIP commitments.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Particulate Matter (PM10) Group II SIP commitments. 52.1637 Section 52.1637 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Particulate Matter (PM10) Group II SIP commitments. (a) On August 19, 1988, the Governor of New Mexico...
A combined epidemiological-exposure panel study was conducted during the summer of 1998 in Baltimore, Maryland. The objectives of the exposure analysis component of the 28-day study were to investigate the statistical relationships between particulate matter (PM) and related co...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-12
...] Approval and Promulgation of Implementation Plans; Georgia; Rome; Fine Particulate Matter 2002 Base Year... is taking direct final action to approve the fine particulate matter (PM 2.5 ) 2002 base year... progress (RFP) plan, contingency measures, a 2002 base year emissions inventory and other planning SIP...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-21
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 52 [EPA-R04-OAR-2010-0153(b); FRL-9717-4] Approval and Promulgation of Implementation Plans; Tennessee; Knoxville; Fine Particulate Matter 2002 Base Year Emissions... approve the 1997 annual fine particulate matter (PM 2.5 ) 2002 base year emissions inventory portion of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
...] Approval and Promulgation of Implementation Plans; Georgia; Atlanta; Fine Particulate Matter 2002 Base Year... is taking direct final action to approve the fine particulate matter (PM 2.5 ) 2002 base year... progress (RFP) plan, contingency measures, a 2002 base year emissions inventory and other planning SIP...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-02
...] Approval and Promulgation of Implementation Plans; Georgia; Macon; Fine Particulate Matter 2002 Base Year... is taking direct final action to approve the fine particulate matter (PM 2.5 ) 2002 base year... progress (RFP) plan, contingency measures, a 2002 base year emissions inventory and other planning SIP...
Li, Wei; Wu, Jun
2014-01-01
Objectives. We assessed how traffic and mobile-source air pollution impacts are distributed across racial/ethnic and socioeconomically diverse groups in port-adjacent communities in southern Los Angeles County, which may experience divergent levels of exposure to port-related heavy-duty diesel truck traffic because of existing residential and land use patterns. Methods. We used spatial regression techniques to assess the association of neighborhood racial/ethnic and socioeconomic composition with residential parcel-level traffic and vehicle-related fine particulate matter exposure after accounting for built environment and land use factors. Results. After controlling for factors associated with traffic generation, we found that a higher percentage of nearby Black and Asian/Pacific Islander residents was associated with higher exposure, a higher percentage of Hispanic residents was associated with higher traffic exposure but lower vehicle particulate matter exposure, and areas with lower socioeconomic status experienced lower exposure. Conclusions. Disparities in traffic and vehicle particulate matter exposure are nuanced depending on the exposure metric used, the distribution of the traffic and emissions, and pollutant dispersal patterns. Future comparative research is needed to assess potential disparities in other transportation and goods movement corridors. PMID:23678919
Houston, Douglas; Li, Wei; Wu, Jun
2014-01-01
We assessed how traffic and mobile-source air pollution impacts are distributed across racial/ethnic and socioeconomically diverse groups in port-adjacent communities in southern Los Angeles County, which may experience divergent levels of exposure to port-related heavy-duty diesel truck traffic because of existing residential and land use patterns. We used spatial regression techniques to assess the association of neighborhood racial/ethnic and socioeconomic composition with residential parcel-level traffic and vehicle-related fine particulate matter exposure after accounting for built environment and land use factors. After controlling for factors associated with traffic generation, we found that a higher percentage of nearby Black and Asian/Pacific Islander residents was associated with higher exposure, a higher percentage of Hispanic residents was associated with higher traffic exposure but lower vehicle particulate matter exposure, and areas with lower socioeconomic status experienced lower exposure. Disparities in traffic and vehicle particulate matter exposure are nuanced depending on the exposure metric used, the distribution of the traffic and emissions, and pollutant dispersal patterns. Future comparative research is needed to assess potential disparities in other transportation and goods movement corridors.
Laceby, J Patrick; Huon, Sylvain; Onda, Yuichi; Vaury, Veronique; Evrard, Olivier
2016-12-01
The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident resulted in radiocesium fallout contaminating coastal catchments of the Fukushima Prefecture. As the decontamination effort progresses, the potential downstream migration of radiocesium contaminated particulate matter from forests, which cover over 65% of the most contaminated region, requires investigation. Carbon and nitrogen elemental concentrations and stable isotope ratios are thus used to model the relative contributions of forest, cultivated and subsoil sources to deposited particulate matter in three contaminated coastal catchments. Samples were taken from the main identified sources: cultivated (n = 28), forest (n = 46), and subsoils (n = 25). Deposited particulate matter (n = 82) was sampled during four fieldwork campaigns from November 2012 to November 2014. A distribution modelling approach quantified relative source contributions with multiple combinations of element parameters (carbon only, nitrogen only, and four parameters) for two particle size fractions (<63 μm and <2 mm). Although there was significant particle size enrichment for the particulate matter parameters, these differences only resulted in a 6% (SD 3%) mean difference in relative source contributions. Further, the three different modelling approaches only resulted in a 4% (SD 3%) difference between relative source contributions. For each particulate matter sample, six models (i.e. <63 μm and <2 mm from the three modelling approaches) were used to incorporate a broader definition of potential uncertainty into model results. Forest sources were modelled to contribute 17% (SD 10%) of particulate matter indicating they present a long term potential source of radiocesium contaminated material in fallout impacted catchments. Subsoils contributed 45% (SD 26%) of particulate matter and cultivated sources contributed 38% (SD 19%). The reservoir of radiocesium in forested landscapes in the Fukushima region represents a potential long-term source of particulate contaminated matter that will require diligent management for the foreseeable future. Copyright © 2016 Elsevier Ltd. All rights reserved.
Residential environmental risks for reproductive age women in developing countries.
Dyjack, David; Soret, Samuel; Chen, Lie; Hwang, Rhonda; Nazari, Nahid; Gaede, Donn
2005-01-01
Published research suggests there is an association between maternal inhalation of common ambient air pollutants and adverse birth outcomes, including an increased risk for preterm delivery, intrauterine growth retardation, small head circumference, low birth weight, and increased rate of malformations. The air pollutants produced by indoor combustion of biomass fuels, used by 50% of households worldwide, have been linked to acute lower respiratory infections, the single most important cause of mortality in children under the age of 5. This report describes a hypothesis-generating study in West Wollega, Ethiopia, conducted to assess airborne particulate matter concentrations in homes that combust biomass fuels (biomass homes). Respirable suspended particulate matter was measured in biomass homes and nonbiomass homes using NIOSH method 0600. Measured airborne particulate concentrations in biomass homes were up to 130 times higher than air quality standards. These findings, in part, confirm that exposure to indoor air pollutants are a major source of concern for mother/child health. Midwives are encouraged to raise awareness, contribute to research efforts, and assist in interventions.
NASA Astrophysics Data System (ADS)
Muñoz, David; Aguilar, Bertha; Fuentealba, Raúl; Préndez, Margarita
2017-03-01
Emissions from motor vehicles are considered to be one of the main sources of airborne particulate matter in Santiago. International researchers have shown that particulate matter contains metal oxides and magnetic particles, both of which are emitted mainly from vehicles exhaust pipes. On the other hand, trees are effective in reducing such contamination, so that they act as passive collectors of particulate matter. This work presents the results obtained from the first magnetic study of the particulate matter collected in two areas of the city of Santiago de Chile. Magnetic susceptibility and Saturation Isothermic Remanent Magnetization (SIRM) were determined in leaves from abundant urban trees and from urban dust samples. Results indicate that most of the samples contain ferromagnetic minerals with magnetite (Fe3O4) as the main carrier. Values of magnetic susceptibility (SI ×10-6 m3/kg) in the range 0.04-0.24 for leaves and in the range 10-45 for urban dust were determinated. In one of the city areas studied, significant correlation between the particulate matter deposited on leaves of Platanus orientalis and measured traffic flows was obtained. In addition, it was possible to estimate that the species Platanus orientalis and Acer negundo have a better ability to capture particulate matter than the species Robinia pseudoacacia.
Exposure to Diesel Exhaust Enhances the Generation of Vascular Microparticles
Introduction: In the study of the health impacts of traffic-related air pollution, diesel exhaust is a pollutant of particular interest, since it is a major source of particulate matter (PM). Epidemiological studies associate exposure to ambient levels of PM with cardiovascular m...
DOT National Transportation Integrated Search
2016-08-01
Biodiesel has diverse sources of feedstock and the amount and composition of its emissions vary significantly depending on : combustion conditions. Results of laboratory and field tests reveal that nitrogen oxides (NOx) and particulate matter (PM) : ...
DOT National Transportation Integrated Search
2010-10-22
The Arizona Department of Transportation (ADOT) sponsored this investigation, a field : study of emissions and air quality impacts generated from a road widening project, to gain : insight into construction-related emissions of particulate matter (PM...
Chemical evolution of atmospheric organic carbon over multiple generations of oxidation
NASA Astrophysics Data System (ADS)
Isaacman-VanWertz, Gabriel; Massoli, Paola; O'Brien, Rachel; Lim, Christopher; Franklin, Jonathan P.; Moss, Joshua A.; Hunter, James F.; Nowak, John B.; Canagaratna, Manjula R.; Misztal, Pawel K.; Arata, Caleb; Roscioli, Joseph R.; Herndon, Scott T.; Onasch, Timothy B.; Lambe, Andrew T.; Jayne, John T.; Su, Luping; Knopf, Daniel A.; Goldstein, Allen H.; Worsnop, Douglas R.; Kroll, Jesse H.
2018-02-01
The evolution of atmospheric organic carbon as it undergoes oxidation has a controlling influence on concentrations of key atmospheric species, including particulate matter, ozone and oxidants. However, full characterization of organic carbon over hours to days of atmospheric processing has been stymied by its extreme chemical complexity. Here we study the multigenerational oxidation of α-pinene in the laboratory, characterizing products with several state-of-the-art analytical techniques. Although quantification of some early generation products remains elusive, full carbon closure is achieved (within measurement uncertainty) by the end of the experiments. These results provide new insights into the effects of oxidation on organic carbon properties (volatility, oxidation state and reactivity) and the atmospheric lifecycle of organic carbon. Following an initial period characterized by functionalization reactions and particle growth, fragmentation reactions dominate, forming smaller species. After approximately one day of atmospheric aging, most carbon is sequestered in two long-lived reservoirs—volatile oxidized gases and low-volatility particulate matter.
Chemical evolution of atmospheric organic carbon over multiple generations of oxidation.
Isaacman-VanWertz, Gabriel; Massoli, Paola; O'Brien, Rachel; Lim, Christopher; Franklin, Jonathan P; Moss, Joshua A; Hunter, James F; Nowak, John B; Canagaratna, Manjula R; Misztal, Pawel K; Arata, Caleb; Roscioli, Joseph R; Herndon, Scott T; Onasch, Timothy B; Lambe, Andrew T; Jayne, John T; Su, Luping; Knopf, Daniel A; Goldstein, Allen H; Worsnop, Douglas R; Kroll, Jesse H
2018-04-01
The evolution of atmospheric organic carbon as it undergoes oxidation has a controlling influence on concentrations of key atmospheric species, including particulate matter, ozone and oxidants. However, full characterization of organic carbon over hours to days of atmospheric processing has been stymied by its extreme chemical complexity. Here we study the multigenerational oxidation of α-pinene in the laboratory, characterizing products with several state-of-the-art analytical techniques. Although quantification of some early generation products remains elusive, full carbon closure is achieved (within measurement uncertainty) by the end of the experiments. These results provide new insights into the effects of oxidation on organic carbon properties (volatility, oxidation state and reactivity) and the atmospheric lifecycle of organic carbon. Following an initial period characterized by functionalization reactions and particle growth, fragmentation reactions dominate, forming smaller species. After approximately one day of atmospheric aging, most carbon is sequestered in two long-lived reservoirs-volatile oxidized gases and low-volatility particulate matter.
Advanced particulate matter control apparatus and methods
Miller, Stanley J [Grand Forks, ND; Zhuang, Ye [Grand Forks, ND; Almlie, Jay C [East Grand Forks, MN
2012-01-10
Apparatus and methods for collection and removal of particulate matter, including fine particulate matter, from a gas stream, comprising a unique combination of high collection efficiency and ultralow pressure drop across the filter. The apparatus and method utilize simultaneous electrostatic precipitation and membrane filtration of a particular pore size, wherein electrostatic collection and filtration occur on the same surface.
Code of Federal Regulations, 2010 CFR
2010-07-01
... must I use to demonstrate initial compliance with the emission limits for particulate matter? 63.9621... the emission limits for particulate matter? (a) You must conduct each performance test that applies to... source, you must determine compliance with the applicable emission limit for particulate matter in Table...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-29
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 52 [EPA-R05-OAR-2012-0088; FRL-9783-4] Approval and Promulgation of Air Quality Implementation Plans; Ohio; Particulate Matter Standards AGENCY: Environmental... submitted a request to approve a section of its particulate matter (PM) rules on February 23, 2012. The PM...
40 CFR 60.45c - Compliance and performance test methods and procedures for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Compliance and performance test methods and procedures for particulate matter. 60.45c Section 60.45c Protection of Environment ENVIRONMENTAL... Compliance and performance test methods and procedures for particulate matter. (a) The owner or operator of...
40 CFR 52.1489 - Particulate matter (PM-10) Group II SIP commitments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Particulate matter (PM-10) Group II SIP commitments. 52.1489 Section 52.1489 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Particulate matter (PM-10) Group II SIP commitments. (a) On March 29, 1989, the Air Quality Officer for the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... must I use to demonstrate initial compliance with the emission limits for particulate matter? 63.7822... demonstrate initial compliance with the emission limits for particulate matter? (a) You must conduct each... applicable emission limit for particulate matter in Table 1 to this subpart, follow the test methods and...
Code of Federal Regulations, 2010 CFR
2010-07-01
... must I use to demonstrate initial compliance with the emission limits for particulate matter? 63.7822... demonstrate initial compliance with the emission limits for particulate matter? (a) You must conduct each... applicable emission limit for particulate matter in Table 1 to this subpart, follow the test methods and...
40 CFR 52.1489 - Particulate matter (PM-10) Group II SIP commitments.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Particulate matter (PM-10) Group II SIP commitments. 52.1489 Section 52.1489 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Particulate matter (PM-10) Group II SIP commitments. (a) On March 29, 1989, the Air Quality Officer for the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... must I use to demonstrate initial compliance with the emission limits for particulate matter? 63.9621... the emission limits for particulate matter? (a) You must conduct each performance test that applies to... source, you must determine compliance with the applicable emission limit for particulate matter in Table...
The final 2008 lead (Pb) national ambient air quality standards (NAAQS) revision maintains Pb in total suspended particulate matter as the indicator. However, the final rule permits the use of low-volume PM10 (particulate matter sampled with a 50% cut-point of 10 μm) F...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-02
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 52 [EPA-R04-OAR-2011-0850-201154(b); FRL-9639-7] Approval and Promulgation of Implementation Plans; Georgia; Macon; Fine Particulate Matter 2002 Base Year... proposing to approve the fine particulate matter (PM 2.5 ) 2002 base year emissions inventory, portion of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 52 [EPA-R04-OAR-2012-0050-201207(b); FRL-9639-3] Approval and Promulgation of Implementation Plans; Georgia; Atlanta; Fine Particulate Matter 2002 Base Year... proposing to approve the fine particulate matter (PM 2.5 ) 2002 base year emissions inventory, portion of...
Settling Efficiency of Urban Particulate Matter Transported by Stormwater Runoff.
Carbone, Marco; Penna, Nadia; Piro, Patrizia
2015-09-01
The main purpose of control measures in urban areas is to retain particulate matter washed out by stormwater over impermeable surfaces. In stormwater control measures, particulate matter removal typically occurs via sedimentation. Settling column tests were performed to examine the settling efficiency of such units using monodisperse and heterodisperse particulate matter (for which the particle size distributions were measured and modelled by the cumulative gamma distribution). To investigate the dependence of settling efficiency from the particulate matter, a variant of the evolutionary polynomial regression (EPR), a Microsoft Excel function based on multi-objective EPR technique (EPR-MOGA), called EPR MOGA XL, was used as a data-mining strategy. The results from this study have shown that settling efficiency is a function of the initial total suspended solids (TSS) concentration and of the median diameter (d50 index), obtained from the particle size distributions (PSDs) of the samples.
NASA Astrophysics Data System (ADS)
Sulovcová, Katarína; Jandačka, Jozef; Nosek, Radovan
2014-08-01
Concentration of solid particles in ambient atmosphere is increasing in many countries nowadays. Particulate matter pollution in higher concentration has harmful impact on human and animal health. Source of particulate matter are not only industry and traffic. Small heat sources with biomass combustion, especially during winter heating season, are also significant producer of particulate matter emission. There is a huge importance to decrease quantities of solid particles which are getting into the atmosphere in every region of their production in order to decrease environmental pollution and improve air quality. The ability of flue gas emission elimination can influence future using of biomass combustion. Therefore effective and affordable solutions are searching for. The paper deals with the reduction of particulate matter in small heat source with biomass combustion by modification of geometric parameters in flue gas path.
Atmospheric pollution measurement by optical cross correlation methods - A concept
NASA Technical Reports Server (NTRS)
Fisher, M. J.; Krause, F. R.
1971-01-01
Method combines standard spectroscopy with statistical cross correlation analysis of two narrow light beams for remote sensing to detect foreign matter of given particulate size and consistency. Method is applicable in studies of generation and motion of clouds, nuclear debris, ozone, and radiation belts.
Hierarchical Bayesian Model (HBM) - Derived Estimates of Air Quality for 2007: Annual Report
This report describes EPA's Hierarchical Bayesian model generated (HBM) estimates of ozone (O3) and fine particulate matter (PM2.5 particles with aerodynamic diameter < 2.5 microns)concentrations throughout the continental United States during the 2007 calen...
A PROBABILISTIC POPULATION EXPOSURE MODEL FOR PM10 AND PM 2.5
A first generation probabilistic population exposure model for Particulate Matter (PM), specifically for predicting PM10, and PM2.5, exposures of an urban, population has been developed. This model is intended to be used to predict exposure (magnitude, frequency, and duration) ...
40 CFR 52.2620 - Identification of plan.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Ambient standards for particulate matter 9/13/99, 10/29/99 7/28/04, 69 FR 44965. Section 3 Ambient... standards for particulate matter 9/13/99, 10/29/99 7/28/04, 69 FR 44965. Section 3 Emission standards for... sources 9/13/99, 10/29/99 7/28/04, 69 FR 44965. Chapter 8 Section 2 Sweetwater County particulate matter...
40 CFR 60.62 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... particulate matter in excess of 0.15 kg per metric ton of feed (dry basis) to the kiln (0.30 lb per ton). (2... subpart shall cause to be discharged into the atmosphere from any clinker cooler any gases which: (1) Contain particulate matter in excess of 0.050 kg per metric ton of feed (dry basis) to the kiln (0.10 lb...
ERIC Educational Resources Information Center
Aydeniz, Mehmet; Bilican, Kader; Kirbulut, Zubeyde Demet
2017-01-01
The purpose of this study was to explore Pre-service Elementary Science Teachers' (PSTs) conceptual understanding of Particulate Nature of Matter (PNM) through a three-tier diagnostic test. Participants were 215 PSTs from Turkey. Data consisted of participants' responses to the Particulate Nature of Matter Test (PNMT). The PNMT consists of…
Code of Federal Regulations, 2011 CFR
2011-07-01
... with the particulate matter standards for existing, new, and reconstructed cupolas? To comply with the... 40 Protection of Environment 10 2011-07-01 2011-07-01 false How do I comply with the particulate matter standards for existing, new, and reconstructed cupolas? 63.1181 Section 63.1181 Protection of...
Code of Federal Regulations, 2011 CFR
2011-07-01
... must I use to demonstrate initial compliance with the emission limits for particulate matter and PM10... compliance with the emission limits for particulate matter and PM10? (a) You must conduct each performance... determine compliance with the applicable emission limits for particulate matter in Table 1 to this subpart...
Code of Federal Regulations, 2010 CFR
2010-07-01
... with the particulate matter standards for existing, new, and reconstructed cupolas? To comply with the... 40 Protection of Environment 10 2010-07-01 2010-07-01 false How do I comply with the particulate matter standards for existing, new, and reconstructed cupolas? 63.1181 Section 63.1181 Protection of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... must I use to demonstrate initial compliance with the emission limits for particulate matter and PM10... compliance with the emission limits for particulate matter and PM10? (a) You must conduct each performance... determine compliance with the applicable emission limits for particulate matter in Table 1 to this subpart...
Impact of Feed Delivery Pattern on Aerial Particulate Matter and Behavior of Feedlot Cattle †
Mitloehner, Frank M.; Dailey, Jeff W.; Morrow, Julie L.; McGlone, John J.
2017-01-01
Simple Summary Fine particulate matter (with less than 2.5 microns diameter; aka PM2.5) are a human and animal health concern because they can carry microbes and chemicals into the lungs. Particulate matter (PM) in general emitted from cattle feedlots can reach high concentrations. When feedlot cattle were given an altered feeding schedule (ALT) that more closely reflected their biological feeding times compared with conventional morning feeding (CON), PM2.5 generation at peak times was substantially lowered. Average daily generation of PM2.5 was decreased by 37% when cattle behavior was redirected away from PM-generating behaviors and toward evening feeding behaviors. Behavioral problems such as agonistic (i.e., aggressive) and bulling (i.e., mounting each other) behaviors also were reduced several fold among ALT compared with CON cattle. Intake of feed was less and daily body weight gain tended to be less with the altered feeding schedule while efficiency of feed utilization was not affected. Although ALT may pose a challenge in feed delivery and labor scheduling, cattle had fewer behavioral problems and reduced PM2.5 generation when feed delivery times matched with the natural drive to eat in a crepuscular pattern. Abstract Fine particulate matter with less than 2.5 microns diameter (PM2.5) generated by cattle in feedlots is an environmental pollutant and a potential human and animal health issue. The objective of this study was to determine if a feeding schedule affects cattle behaviors that promote PM2.5 in a commercial feedlot. The study used 2813 crossbred steers housed in 14 adjacent pens at a large-scale commercial West Texas feedlot. Treatments were conventional feeding at 0700, 1000, and 1200 (CON) or feeding at 0700, 1000, and 1830 (ALT), the latter feeding time coincided with dusk. A mobile behavior lab was used to quantify behaviors of steers that were associated with generation of PM2.5 (e.g., fighting, mounting of peers, and increased locomotion). PM2.5 samplers measured respirable particles with a mass median diameter ≤2.5 μm (PM2.5) every 15 min over a period of 7 d in April and May. Simultaneously, the ambient temperature, humidity, wind speed and direction, precipitation, air pressure, and solar radiation were measured with a weather station. Elevated downwind PM2.5 concentrations were measured at dusk, when cattle that were fed according to the ALT vs. the CON feeding schedule, demonstrated less PM2.5-generating behaviors (p < 0.05). At dusk, steers on ALT vs. CON feeding schedules ate or were waiting to eat (standing in second row behind feeding cattle) at much greater rates (p < 0.05). Upwind PM2.5 concentrations were similar between the treatments. Downwind PM2.5 concentrations averaged over 24 h were lower from ALT compared with CON pens (0.072 vs. 0.115 mg/m3, p < 0.01). However, dry matter intake (DMI) was less (p < 0.05), and average daily gain (ADG) tended to be less (p < 0.1) in cattle that were fed according to the ALT vs. the CON feeding schedules, whereas feed efficiency (aka gain to feed, G:F) was not affected. Although ALT feeding may pose a challenge in feed delivery and labor scheduling, cattle exhibited fewer PM2.5-generating behaviors and reduced generation of PM2.5 when feed delivery times matched the natural desires of cattle to eat in a crepuscular pattern. PMID:28257061
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-14
... Matter and Ozone; Correction AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule..., Nitrogen oxides, Ozone, Particulate matter, Regional haze, Reporting and recordkeeping requirements, Sulfur...
CHARACTERIZATION OF EMISSIONS FROM BURNING INCENSE
The primary objective of this study was to improve the characterization of particulate matter emissions from burning incense. Emissions of particulate matter were measured for 23 different types of incense using a cyclone/filter method. Emission rates for PM2.5 (particulate matte...
INTERNATIONAL APPROACHES TO DEVELOPING STANDARDS FOR NONCRITERIA POLLUTANTS
Much of the initial interest in the control of pollutants, both in the United States and abroad, focused on such "traditional" pollutants as sulfur dioxide, particulate matter, Total Suspended Particulate (TSP) and particulate matter, nitrogen oxides, carbon monoxide, ozone, and ...
Kuwaiti oil fires—Particulate monitoring
NASA Astrophysics Data System (ADS)
Husain, Tahir; Amin, Mohamed B.
The total suspended particulate (TSP) matters using a high-volume sampler and inhalable particulate matters using PM-10 samplers were collected at various locations in the Eastern Province of Saudi Arabia during and after the Kuwaiti oil fires. The collected samples were analysed for toxic metals and oil hydrocarbon concentrations including some carcinogenic organic compounds in addition to gravimetric analysis. The concentration values of particulate matters were determined on a daily basis at Dhahran. Abqaiq, Rahima, Tanajib and Jubail locations. The analyses of the filters show a high concentration of the inhalable particulate at various locations, especially when north or northwest winds were blowing. It was found that the inhalable particulate concentration exceeded the Meteorology and Environmental Protection Administration (MEPA) permissible limit of 340 μg m- 3 at most of these locations during May-October 1991. A trend between the total suspended particulate and inhalable particulate measured concurrently at the same locations was observed and a regression equation was developed to correlate PM-10 data with the total suspended particulate data.
Particulate air pollution from bushfires: human exposure and possible health effects.
Karthikeyan, Sathrugnan; Balasubramanian, Rajasekhar; Iouri, Kostetski
2006-11-01
Toxicological studies have implicated trace metals adsorbed onto airborne particles as possible contributors to respiratory and/or cardiovascular inflammation. In particular, the water-soluble metal content is considered to be a harmful component of airborne particulate matter. In this work, the trace metal characteristics of airborne particulate matter, PM2.5, collected in Singapore from February to March 2005 were investigated with specific reference to their bioavailability. PM2.5 mass concentrations varied between 20.9 mug/m3 and 46.3 microg/m3 with an average mass of 32.8 microg/m3. During the sampling period, there were several bushfires in Singapore that contributed to sporadic increases in the particulate air pollution, accompanied by an acrid smell and asthma-related allergies. The aerosol samples were subjected to analysis of trace elements for determining their total concentrations as well as their water soluble fractions. Our results showed an increase in concentration of several water-soluble trace metals during bushfires compared to their urban background levels in Singapore. In order to measure the human exposure to particulate air pollution, the daily respiratory uptake (DRU) of several trace metals was calculated and compared between haze and nonhaze periods. The DRU values were significantly higher for several metals, including Zn, Cu, and Fe, during bushfires. Electron paramagnetic resonance (EPR) measurements showed that the particulate samples collected during bush fires generate more toxic hydroxyl radicals (OH.) than those in the background air, due to the presence of more soluble iron ions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of Particulate Matter as PM10 in the Atmosphere J Appendix J to Part 50 Protection of Environment... STANDARDS Pt. 50, App. J Appendix J to Part 50—Reference Method for the Determination of Particulate Matter... sampler draws ambient air at a constant flow rate into a specially shaped inlet where the suspended...
Code of Federal Regulations, 2011 CFR
2011-07-01
... of Particulate Matter as PM10 in the Atmosphere J Appendix J to Part 50 Protection of Environment... STANDARDS Pt. 50, App. J Appendix J to Part 50—Reference Method for the Determination of Particulate Matter... sampler draws ambient air at a constant flow rate into a specially shaped inlet where the suspended...
Method for removing particulate matter from a gas stream
Postma, Arlin K.
1984-01-01
Particulate matter is removed from a stream of pressurized gas by directing the stream of gas upwardly through a bed of porous material, the porous bed being held in an open ended container and at least partially submerged in liquid. The passage of the gas through the porous bed sets up a circulation in the liquid which cleans the particulate matter from the bed.
ERIC Educational Resources Information Center
Othman, Jazilah; Treagust, David F.; Chandrasegaran, A. L.
2008-01-01
A thorough understanding of chemical bonding requires familiarity with the particulate nature of matter. In this study, a two-tier multiple-choice diagnostic instrument consisting of ten items (five items involving each of the two concepts) was developed to assess students' understanding of the particulate nature of matter and chemical bonding so…
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 9 2012-07-01 2012-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 9 2013-07-01 2013-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 9 2014-07-01 2014-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...
Inorganic PM in poultry house using rice hull bedding
USDA-ARS?s Scientific Manuscript database
The persistence and long life expectancy of ammonia, odors and toxic pollutants from poultry houses may be due to the ability of suspended particulate matters (SPM) to serve as carriers for odorous compounds such as ammonium ions and volatile organic compounds. SPM is generated from the feed, anima...
The United States Environmental Protection Agency's (EPA) National Exposure Research Laboratory is developing improved methods for modeling the source through the air pathway to human exposure in significant microenvironments of exposure. As a part of this project, we develope...
EPA proposes withdrawing the federal implementation plan provisions that require affected electricity generating units (EGUs) in Texas to participate in Phase 2 of the Cross-State Air Pollution Rule trading programs for annual emissions of SO2 and NOx.
Hierarchical Bayesian Model (HBM) - Derived Estimates of Air Quality for 2008: Annual Report
This report describes EPA’s Hierarchical Bayesian model generated (HBM) estimates of ozone (O3) and fine particulate matter (PM2.5, particles with aerodynamic diameter < 2.5 microns) concentrations throughout the continental United States during the 2007 ca...
Primary ultrafine particulate matter (PM) is produced during pulverized coal combustion by the nucleation and heterogeneous condensation of vapor-phase species. This differs from the mechanisms that control the formation of the supermicron fly ash that is heavily influenced by t...
Ozone (O3), particulate matter (PM), and nitrogen dioxide (NO2) are criteria pollutants used to evaluate air quality. Using EPA’s Mobile Reaction Chamber (MRC), we generated 2 simulated-smog atmospheres (SSA-1 & SSA-2) with different concentrations of these criteria pol...
40 CFR 52.725 - Control strategy: Particulates.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status... Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance... the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM...
40 CFR 52.725 - Control strategy: Particulates.
Code of Federal Regulations, 2010 CFR
2010-07-01
... requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status... Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance... the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM...
40 CFR 52.725 - Control strategy: Particulates.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status... Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance... the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM...
40 CFR 52.725 - Control strategy: Particulates.
Code of Federal Regulations, 2014 CFR
2014-07-01
... requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status... Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance... the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM...
STATISTICAL ISSUES IN THE STUDY OF AIR POLLUTION INVOLVING AIRBORNE PARTICULATE MATTER
Epidemiological research in the early 1990s focusing on health effects of airborne particulate matter pointed to a statistical association between increases in concentration of particulate in ambient air and increases in daily nonaccidental mortality, particularly among the eld...
Shideler, G.L.
1981-01-01
A monitoring study of suspended sediment on the South Texas Continental Shelf indicates that a turbid benthic nepheloid layer is regionally persistent. A sequence of quasi-synoptic measurements of the water column obtained during six cruises in an 18-month period indicates substantial spatial and temporal variability in nepheloidlayer characteristics. Regionally, the thickness of the shelf nepheloid layer increases both seaward and in a convergent alongshelf direction. Greatest thicknesses occur over a muddy substrate, indicating a causal relationship; maximum observed local thickness is 35 m which occurs along the southern shelf break. Analyses of suspended particulate matter in shelf bottom waters indicate mean concentrations ranging from 49 ?? 104 to 111 ?? 104 particle counts/cc; concentrations persistently increase shoreward throughout the region. Bottom particulate matter is predominantly composed of inorganic detritus. Admixtures of organic skeletal particles, primarily diatoms, are generally present but average less than 10% of the total particulate composition. Texturally, the particulate matter in bottom waters is predominantly poorly sorted sediment composed of very fine silt (3.9-7.8 ??m). The variability in nepheloid-layer characteristics indicates a highly dynamic shelf feature. The relationship of nepheloid-layer characteristics to hydrographic and substrate conditions suggests a conceptual model whereby nepheloid-layer development and maintenance are the results of the resuspension of sea-floor sediment. Bottom turbulence is attributed primarily to vertical shear and shoaling progressive internal waves generated by migrating shelf-water masses, especially oceanic frontal systems, and secondarily to shoaling surface gravity waves. ?? 1981.
Soil separator and sampler and method of sampling
O'Brien, Barry H [Idaho Falls, ID; Ritter, Paul D [Idaho Falls, ID
2010-02-16
A soil sampler includes a fluidized bed for receiving a soil sample. The fluidized bed may be in communication with a vacuum for drawing air through the fluidized bed and suspending particulate matter of the soil sample in the air. In a method of sampling, the air may be drawn across a filter, separating the particulate matter. Optionally, a baffle or a cyclone may be included within the fluidized bed for disentrainment, or dedusting, so only the finest particulate matter, including asbestos, will be trapped on the filter. The filter may be removable, and may be tested to determine the content of asbestos and other hazardous particulate matter in the soil sample.
Lazaridis, Mihalis; Semb, Arne; Larssen, Steinar; Hjellbrekke, Anne-Gunn; Hov, Oystein; Hanssen, Jan Erik; Schaug, Jan; Tørseth, Kjetil
2002-02-21
Particulate matter (PM) monitoring presents a new challenge to the transboundary air pollution strategies in Europe. Evidence for the role of long-range transport of particulate matter and its significant association with a wide range of adverse health effects has urged for the inclusion of particulate matter within the European Monitoring and Evaluation Programme (EMEP) framework. Here we review available data on PM physico-chemical characteristics within the EMEP framework. In addition we identify future research needs for the characterisation of the background PM in Europe that include detailed harmonised measurements of mass, size and chemical composition (mass closure) of the ambient aerosol.
A Study on Characteristics of Atmospheric Heavy Metals in Subway Station
Kim, Chun-Huem; Yoo, Dong-Chul; Kwon, Young-Min; Han, Woong-Soo; Kim, Gi-Sun; Park, Mi-Jung; Kim, Young Soon
2010-01-01
In this study, we investigated the atmospheric heavy metal concentrations in the particulate matter inside the subway stations of Seoul. In particular, we examined the correlation between the heavy metals and studied the effect of the heavy metals on cell proliferation. In six selected subway stations in Seoul, particulate matter was captured at the platforms and 11 types of heavy metals were analyzed. The results showed that the mean concentration of iron was the highest out of the heavy metals in particulate matter, followed by copper, potassium, calcium, zinc, nickel, sodium, manganese, magnesium, chromium and cadmium in that order. The correlation analysis showed that the correlations between the heavy metals was highest in the following order: (Cu vs Zn) , (Ca vs Na) , (Ca vs Mn) , (Ni vs Cr) , (Na vs Mn) , (Cr vs Cd) , (Zn vs Cd) , (Cu vs Cd) , (Ni vs Cd) , (Cu vs Ni) , (K vs Zn) , (Cu vs K) , (Cu vs Cr) , (K vs Cd) , (Zn vs Cr) , (K vs Ni) , (Zn vs Ni) , (K vs Cr) , and (Fe vs Cu) . The correlation coefficient between zinc and copper was 0.937, indicating the highest correlation. Copper, zinc, nickel, chromium and cadmium, which are generated from artificial sources in general, showed correlations with many of the other metals and the correlation coefficients were also relatively high. The effect of the heavy metals on cell proliferation was also investigated in this study. Cultured cell was exposed to 10 mg/l or 100 mg/l of iron, copper, calcium, zinc, nickel, manganese, magnesium, chromium and cadmium for 24 hours. The cell proliferation in all the heavy metal-treated groups was not inhibited at 10 mg/l of the heavy metal concentration. The only exception to this was with the cadmium-treated group which showed a strong cell proliferation inhibition. This study provides the fundamental data for the understanding of simultaneous heavy metal exposure tendency at the time of particulate matter exposure in subway stations and the identification of heavy metal sources. Moreover, this study can be used as the fundamental data for the cell toxicity study of the subway-oriented heavy metal-containing particulate matter. PMID:24278519
NASA Astrophysics Data System (ADS)
Armin, W.; Mueller, M.; Klinger, A.; Striednig, M.
2017-12-01
A quantitative characterization of the organic fraction of atmospheric particulate matter is still challenging. Herein we present the novel modular "Chemical Analysis of Aerosol Online" (CHARON) particle inlet system coupled to a new-generation proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF 6000 X2, Ionicon Analytik, Austria) that quantitatively detects organic analytes in real-time and sub-pptV levels by chemical ionization with hydronium reagent ions. CHARON consists of a gas-phase denuder for stripping off gas-phase analytes (efficiency > 99.999%), an aerodynamic lens for particle collimation combined with an inertial sampler for the particle-enriched flow and a thermodesorption unit for particle volatilization prior to chemical analysis. With typical particle enrichment factors of around 30 for particle diameters (DP) between 120 nm and 1000 nm (somewhat reduced enrichment for 60 nm < DP < 120 nm) we boost the already excellent limits of detection of the PTR-TOF 6000 X2 system to unprecedented levels. We demonstrate that particulate organic analytes of mass concentrations down to 100 pg m-3 can be detected on-line and in single-minute time-resolutions. In addition, PTR-MS allows for a quantitative detection of almost the full range of particulate organics of intermediate to low volatility. With the high mass resolution (R > 6000) and excellent mass accuracies (< 10 ppm) chemical compositions can be assigned and included in further analyses. In addition to a detailed characterization of the CHARON PTR-TOF 6000 X2 we will present first results on the chemical composition of sub-µm particulate organic matter in the urban atmosphere in Innsbruck (Austria).
Urban air-quality assessment and source apportionment studies for Bhubaneshwar, Odisha
NASA Astrophysics Data System (ADS)
Mahapatra, Parth Sarathi; Ray, Sanak; Das, Namrata; Mohanty, Ayusman; Ramulu, T. S.; Das, Trupti; Chaudhury, G. Roy; Das, S. N.
2013-04-01
Acid- and water-soluble component of suspended particulate matter was studied from January 2009 to December 2009 at Bhubaneshwar, an urban coastal location of eastern India, by high-volume sampler, environmental dust monitor using GRIMM®, and scanning electron microscope and energy dispersive X-ray spectrometer. The water-soluble components accounted for 30-45 % of the total suspended particulate matter, and the major elements were observed to be ammonium and nitrate as the cationic and anionic species, respectively. The acid-soluble component like copper, nickel, cobalt, iron, and lead accounted for 5-15 % of the total particulate matter concentration. The composition of particulate matter shows a clear seasonal variation in relation to wind speed, wind direction, and trajectories of the air mass movement. The GRIMM spectrometer analysis shows higher concentration of fine particulate matter. Source apportionment and enrichment factor analysis indicated that except sodium and chloride, all other elements have emerged from different sources such as crustal as well as anthropogenic.
Regional air quality impacts of increased natural gas production and use in Texas.
Pacsi, Adam P; Alhajeri, Nawaf S; Zavala-Araiza, Daniel; Webster, Mort D; Allen, David T
2013-04-02
Natural gas use in electricity generation in Texas was estimated, for gas prices ranging from $1.89 to $7.74 per MMBTU, using an optimal power flow model. Hourly estimates of electricity generation, for individual electricity generation units, from the model were used to estimate spatially resolved hourly emissions from electricity generation. Emissions from natural gas production activities in the Barnett Shale region were also estimated, with emissions scaled up or down to match demand in electricity generation as natural gas prices changed. As natural gas use increased, emissions decreased from electricity generation and increased from natural gas production. Overall, NOx and SO2 emissions decreased, while VOC emissions increased as natural gas use increased. To assess the effects of these changes in emissions on ozone and particulate matter concentrations, spatially and temporally resolved emissions were used in a month-long photochemical modeling episode. Over the month-long photochemical modeling episode, decreases in natural gas prices typical of those experienced from 2006 to 2012 led to net regional decreases in ozone (0.2-0.7 ppb) and fine particulate matter (PM) (0.1-0.7 μg/m(3)). Changes in PM were predominantly due to changes in regional PM sulfate formation. Changes in regional PM and ozone formation are primarily due to decreases in emissions from electricity generation. Increases in emissions from increased natural gas production were offset by decreasing emissions from electricity generation for all the scenarios considered.
Hubeny, J Bradford; Kenney, Melanie; Warren, Barbara; Louisos, Jeremy
2017-01-01
Turbidity is a water quality parameter that is known to adversely affect aquatic systems, however the causes of turbid water are often elusive. We present results of a study designed to constrain the source of particulate matter in a coastal embayment that has suffered from increased turbidity over past decades. Our approach utilized monitoring buoys to quantify turbidity at high temporal resolution complemented by geochemical isotope analysis of suspended sediment samples and meteorological data. Results reveal a complex system in which multiple sources are associated with particulate matter. Weight of evidence demonstrates that phytoplankton productivity in the water column, however, is the dominant source of particulate matter associated with elevated turbidity in Salem Harbor, Massachusetts. Allochthonous matter from the watershed was observed to mix into the pool of suspended particulate matter near river mouths, especially in spring and summer. Resuspension of harbor surface sediments likely provides additional particulates in the regions of boat moorings, especially during summer when recreational boats are attached to moorings. Our approach allows us to constrain the causes of turbidity events in this embayment, is helping with conservation efforts of environmental quality in the region, and can be used as a template for other locations. Copyright © 2016 Elsevier B.V. All rights reserved.
Gass, Katherine; Balachandran, Sivaraman; Chang, Howard H.; Russell, Armistead G.; Strickland, Matthew J.
2015-01-01
Epidemiologic studies utilizing source apportionment (SA) of fine particulate matter have shown that particles from certain sources might be more detrimental to health than others; however, it is difficult to quantify the uncertainty associated with a given SA approach. In the present study, we examined associations between source contributions of fine particulate matter and emergency department visits for pediatric asthma in Atlanta, Georgia (2002–2010) using a novel ensemble-based SA technique. Six daily source contributions from 4 SA approaches were combined into an ensemble source contribution. To better account for exposure uncertainty, 10 source profiles were sampled from their posterior distributions, resulting in 10 time series with daily SA concentrations. For each of these time series, Poisson generalized linear models with varying lag structures were used to estimate the health associations for the 6 sources. The rate ratios for the source-specific health associations from the 10 imputed source contribution time series were combined, resulting in health associations with inflated confidence intervals to better account for exposure uncertainty. Adverse associations with pediatric asthma were observed for 8-day exposure to particles generated from diesel-fueled vehicles (rate ratio = 1.06, 95% confidence interval: 1.01, 1.10) and gasoline-fueled vehicles (rate ratio = 1.10, 95% confidence interval: 1.04, 1.17). PMID:25776011
Fine Particulate Matter Concentrations in Urban Chinese Cities, 2005-2016: A Systematic Review.
He, Mike Z; Zeng, Xiange; Zhang, Kaiyue; Kinney, Patrick L
2017-02-14
Background : Particulate matter pollution has become a growing health concern over the past few decades globally. The problem is especially evident in China, where particulate matter levels prior to 2013 are publically unavailable. We conducted a systematic review of scientific literature that reported fine particulate matter (PM 2.5 ) concentrations in different regions of China from 2005 to 2016. Methods : We searched for English articles in PubMed and Embase and for Chinese articles in the China National Knowledge Infrastructure (CNKI). We evaluated the studies overall and categorized the collected data into six geographical regions and three economic regions. Results : The mean (SD) PM 2.5 concentration, weighted by the number of sampling days, was 60.64 (33.27) μg/m³ for all geographic regions and 71.99 (30.20) μg/m³ for all economic regions. A one-way ANOVA shows statistically significant differences in PM 2.5 concentrations between the various geographic regions (F = 14.91, p < 0.0001) and the three economic regions (F = 4.55, p = 0.01). Conclusions: This review identifies quantifiable differences in fine particulate matter concentrations across regions of China. The highest levels of fine particulate matter were found in the northern and northwestern regions and especially Beijing. The high percentage of data points exceeding current federal regulation standards suggests that fine particulate matter pollution remains a huge problem for China. As pre-2013 emissions data remain largely unavailable, we hope that the data aggregated from this systematic review can be incorporated into current and future models for more accurate historical PM 2.5 estimates.
Ni, Yang; Tu, Xing-ying; Zhu, Yi-dan; Guo, Xin-biao; Deng, Fu-rong
2014-06-18
To study the concentrations of fine particulate matters and ultrafine particles and influenced factors during winter in an area of Beijing. Real-time monitoring of particles' mass and number concentrations were conducted in an area of Beijing from February 7(th) to 27(th), 2013. At the same time, the meteorological data were also collected from the Beijing meteorological website. Differences of the particles' mass and number concentrations during different periods were analyzed using Mann-Whitney U test. Meanwhile, the influenced factors were also analyzed. The mean concentrations of fine particulate matters and ultrafine particles were (157.2 ± 142.8) μg/m³ and (25 018 ± 9 309) particles/cm³, respectively. The particles' number and mass concentrations in haze days were 1.27 times and 2.91 times higher than those in non-haze days, respectively. The mass concentrations of fine particulate matters in the self-monitoring site were higher than those in the nearest central monitoring sites, and the hourly-average concentrations of particles were significantly consistent with those at the commuter times. Meanwhile, the setting off of fireworks/firecrackers during the Spring Festival could lead to short-term increases of the particles' number and mass concentrations. When the wind speed was low and the related humidity was high, the concentrations of particulate matters were relatively high, and the mass concentrations of fine particulate matters were lagged about 1-2 d. The level of the particulate matters in this area was high. Heavy traffic, setting off of fireworks/firecrackers and meteorological factors may be some of the main factors affecting the concentrations of the particulate matters in this area. Among those factors, the effect of setting off of fireworks/firecrackers didn't last long and the effect of the meteorological factors had a hysteresis effect.
Systems and methods for controlling diesel engine emissions
Webb, Cynthia Chaffin; Weber, Phillip Anthony; Khair, Magdi K.
2004-06-01
Systems and methods for controlling diesel engine emissions, including, for example, oxides of nitrogen emissions, particulate matter emissions, and the like. The emission control system according to this invention is provided in the exhaust passageway of a diesel engine and includes a catalyst-based particulate filter; and first and second lean NO.sub.x trap systems coupled to the catalyst-based particulate filter. The first and second lean NO.sub.x trap systems are arranged in a parallel flow configuration with each other. Each of the first and second lean NO.sub.x trap systems include a carbon monoxide generating catalyst device, a sulfur trap device, a lean NO.sub.x device, a supplemental fuel injector device, and a plurality of flow diverter devices.
Stable Isotopic Composition of Particulate Organic Carbon in the Caspian Sea
NASA Astrophysics Data System (ADS)
Kravchishina, M. D.; Klyuvitkin, A. A.; Pautova, L. A.; Politova, N. V.; Lein, A. Yu.
2018-01-01
The data on the isotopic composition of particulate organic carbon (δ13CPOC) in the Caspian Sea water in summer-autumn 2008, 2010, 2012, and 2013 are discussed in the paper. These data allowed as to reveal the predominant genesis of organic carbon in suspended particulate matter of the active seawater layer (from 0 to 40 m). The δ13CPOC =-27‰ (PDB) and δ13CPOC =-20.5‰ (PDB) values were taken as the reference data for terrigenous and planktonogenic organic matter, respectively. Seasonal (early summer, late summer, and autumn) variations in the composition of suspended particulate matter in the active sea layer were revealed. A shift of δ13CPOC towards greater values was seen in autumn (with a slight outburst in the development (bloom) of phytoplankton) in comparison with summer (with large accumulations and an extraordinary phytoplankton bloom confined to the thermocline area). The seasonal dynamics of autochthonous and allochthonous components in the suspended particulate matter of the Middle and Southern Caspian Sea was studied with the use of data on the concentration of particulate matter and chlorophyll a, the phytoplankton biomass and the POC content.
NASA Astrophysics Data System (ADS)
Ravi, Sujith; Sharratt, Brenton S.; Li, Junran; Olshevski, Stuart; Meng, Zhongju; Zhang, Jianguo
2016-10-01
Novel carbon sequestration strategies such as large-scale land application of biochar may provide sustainable pathways to increase the terrestrial storage of carbon. Biochar has a long residence time in the soil and hence comprehensive studies are urgently needed to quantify the environmental impacts of large-scale biochar application. In particular, black carbon emissions from soils amended with biochar may counteract the negative emission potential due to the impacts on air quality, climate, and biogeochemical cycles. We investigated, using wind tunnel experiments, the particulate matter emission potential of a sand and two agriculturally important soils amended with different concentrations of biochar, in comparison to control soils. Our results indicate that biochar application considerably increases particulate emissions possibly by two mechanisms-the accelerated emission of fine biochar particles and the generation and emission of fine biochar particles resulting from abrasion of large biochar particles by sand grains. Our study highlights the importance of considering the background soil properties (e.g., texture) and geomorphological processes (e.g., aeolian transport) for biochar-based carbon sequestration programs.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-02
... Matter and Ozone AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of public hearings... Implementation Plans to Reduce Interstate Transport of Fine Particulate Matter and Ozone'' (Transport Rule) which... matter (PM 2.5 ) national ambient air quality standards (NAAQS) and the 1997 ozone NAAQS. Public hearing...
2015-12-30
FINAL REPORT Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM...Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions 6. AUTHOR(S) E. Corporan, M...report contains color. 14. ABSTRACT This project consists of demonstrating the performance and viability of two devices to condition aircraft turbine
Wooten, Kimberly J; Sandoz, Melissa A; Smith, Philip N
2018-04-01
Beef cattle in the United States are routinely administered ractopamine, a β-adrenergic receptor agonist, to enhance growth. The present study is the first to quantify ractopamine in feedyard-emitted particulate matter and playa wetlands near feedyards. Ractopamine was present in 92% of particulate matter samples, 16% of playa sediment samples, and 3% of playa water samples, at maximum concentrations of 4.7 μg/g, 5.2 ng/g (dry wt), and 271 ng/L, respectively. These data suggest that aerial transmission and deposition of particulate matter is a transport mechanism for ractopamine between feedyards and aquatic systems in the region. Environ Toxicol Chem 2018;37:970-974. © 2017 SETAC. © 2017 SETAC.
Design and Calibration of a High Volume Cascade Impactor
ERIC Educational Resources Information Center
Gussman, R. A.; And Others
1973-01-01
This study was to develop an air sampling device capable of classifying large quantities of airborne particulate matter into discrete size fractions. Such fractionation will facilitate chemical analysis of the various particulate pollutants and thereby provide a more realistic assessment of the effects of particulate matter on human beings. (BL)
TEST METHODS TO CHARACTERIZE PARTICULATE MATTER EMISSIONS AND DEPOSITION RATES IN A RESEARCH HOUSE
The paper discusses test methods to characterize particulate matter (PM) emissions and deposition rates in a research house. In a room in the research house, specially configured for PM source testing, a high-efficiency particulate air (HEPA)-filtered air supply system, used for...
Design and evaluation of a low-volume total suspended particulate sampler
USDA-ARS?s Scientific Manuscript database
The regulation of particulate matter (PM) emitted by agricultural sources, e.g., cotton gins, feed mills, and concentrated animal feeding operations (CAFOs), is based on downwind concentrations of particulate matter less than 10 and 2.5 'm (PM10 and PM2.5) aerodynamic equivalent diameter (AED). Both...
Population exposure to ambient particulate matter (PM) has received considerable attention due to the association between ambient particulate concentrations and mortality. Current toxicological studies and controlled human and animal exposures suggest that all size fractions of...
This work was motivated by the need to better reconcile emission factors for fugitive dust with the amount of geologic material found on ambient filter samples. The deposition of particulate matter with aerodynamic diameter less than or equal to 10 µm (PM10), generated...
Airborne particulate matter (PM) is an important risk factor for asthma. Generation of oxidative stress by PM-associated chemicals is a major mechanism of its health effects. Transcription factor nuclear factor (erythroid-derived 2)-like 2 (Nrf2) mediates antioxidant and phase II...
Wildland fires, favored by prolonged drought and rising temperatures, generate significant amounts of ambient particulate matter (PM), which has been linked to adverse health outcomes. The eastern North Carolina peat fires of Pocosin Lake in 2008 and Pains Bay in 2011 were some o...
Ozone (O3), particulate matter (PM), and nitrogen dioxide (NO2) are criteria pollutants used to evaluate air quality. Using a 14.3-m3 Teflon-lined smog chamber with 120 UV bulbs to simulate solar radiation, we generated 2 simulated-smog atmospheres (SSA-1 & SSA-2) with differ...
Assessing the impact of fine particulate matter (PM2.5) on ...
An enhanced research paradigm is presented to address the spatial and temporal gaps in fine particulate matter (PM2.5) measurements and generate realistic and representative concentration fields for use in epidemiological studies of human exposure to ambient air particulate concentrations. The general approach for research designed to analyze health impacts of exposure to PM2.5 is to use concentration data from the nearest ground-based air quality monitor(s), which typically have missing data on the temporal and spatial scales due to filter sampling schedules and monitor placement, respectively. To circumvent these data gaps, this research project uses a Hierarchical Bayesian Model (HBM) to generate estimates of PM2.5 in areas with and without air quality monitors by combining PM2.5 concentrations measured by monitors, PM2.5 concentration estimates derived from satellite aerosol optical depth (AOD) data, and Community-Multiscale Air Quality (CMAQ) model predictions of PM2.5 concentrations. This methodology represents a substantial step forward in the approach for developing representative PM2.5 concentration datasets to correlate with inpatient hospitalizations and emergency room visits data for asthma and inpatient hospitalizations for myocardial infarction (MI) and heart failure (HF) using case-crossover analysis. There were two key objective of this current study. First was to show that the inputs to the HBM could be expanded to include AOD data in addition t
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, P.A.; Rasmussen, J.B.; Blaise, C.
1998-02-01
Previous investigations of organic genotoxins in industrial effluents discharged into the St. Lawrence River system (Quebec, Canada) indicated that a substantial fraction of the genotoxicity is adsorbed to suspended particulate matter. This study used the SOS Chromotest to investigate the presence, potency, and behavior of particle-bound genotoxins in the downstream ecosystem. The results indicate that although extracts of both suspended and sedimented particulate matter are genotoxic, suspended particulate matter samples are more potent in the absence of S9 activation, with the reverse being true for bottom sediments. The results confirmed a positive relationship between the genotoxicity of bottom sediment extractsmore » and sediment organic matter content. A similar relationship between organic matter content and total polycyclic aromatic hydrocarbon (PAH) concentration indicates that putative genotoxins have physicochemical properties similar to the PAH class of contaminants. Conversion of PAH values to benzo[a]pyrene equivalents indicates that measured PAHs only account for a small fraction ({approximately}10%) of the observed SOS Chromotest response. Sites that receive discharges from foundries, aluminum refineries, and petroleum refineries yielded several of the most genotoxic samples. Further analyses revealed that the genotoxicity of suspended and sedimented particulate matter extracts is empirically related to the genotoxicity of industrial discharges. Comparisons of total genotoxicity levels in suspended particulates and bottom sediments suggest that direct-acting substances adsorbed to suspended matter are rapidly degraded and/or converted to more stable progenotoxins upon deposition. Further research is required to test this hypothesis and investigate effects on indigenous biota.« less
Particulate Matter (PM) Pollution
Particulate matter (PM) is one of the air pollutants regulated by the National Ambient Air Quality Standards (NAAQS). Reducing emissions of inhalable particles improves public health as well as visibility.
Leenheer, Jerry A.; Rostad, Colleen E.
2004-01-01
Organic matter in wastewater sampled from a swine waste-retention basin in Iowa was fractionated into 14 fractions on the basis of size (particulate, colloid, and dissolved); volatility; polarity (hydrophobic, transphilic, hydrophilic); acid, base, neutral characteristics; and precipitate or flocculates (floc) formation upon acidification. The compound-class composition of each of these fractions was determined by infrared and 13C-NMR spectral analyses. Volatile acids were the largest fraction with acetic acid being the major component of this fraction. The second most abundant fraction was fine particulate organic matter that consisted of bacterial cells that were subfractionated into extractable lipids consisting of straight chain fatty acids, peptidoglycans components of bacterial cell walls, and protein globulin components of cellular plasma. The large lipid content of the particulate fraction indicates that non-polar contaminants, such as certain pharmaceuticals added to swine feed, likely associate with the particulate fraction through partitioning interactions. Hydrocinnamic acid is a major component of the hydrophobic acid fraction, and its presence is an indication of anaerobic degradation of lignin originally present in swine feed. This is the first study to combine particulate organic matter with dissolved organic matter fractionation into a total organic matter fractionation and characterization.
NASA Astrophysics Data System (ADS)
Sówka, Izabela; Chlebowska-Styś, Anna; Mathews, Barbara
2018-01-01
It is commonly known, that suspended particulate matter pose a threat to human life and health, negatively influence the flora, climate and also materials. Especially dangerous is the presence of high concentration of particulate matter in the area of cities, where density of population is high. The research aimed at determining the variability of suspended particulate matter concentration (PM1.0, PM2.5 and PM10) in two different thermal seasons, in the area of Poznań city. As a part of carried out work we analyzed the variability of concentrations and also performed a preliminary analysis of their correlation. Measured concentrations of particulate matter were contained within following ranges: PM10 - 8.7-69.6 μg/m3, PM2.5 - 2.2-88.5 μg/m3, PM1.0 - 2.5-22.9 μg/m3 in the winter season and 1.0-42.8 μg/m3 (PM10), 1.2-40.3 μg/m3 (PM2.5) and 2.7-10.4 (PM1.0) in the summer season. Preliminary correlative analysis indicated interdependence between the temperature of air, the speed of wind and concentration of particulate matter in selected measurement points. The values of correlation coefficients between the air temperature, speed of wind and concentrations of particulate matter were respectively equal to: for PM10: -0.59 and -0.55 (Jana Pawła II Street), -0.53 and -0.53 (Szymanowskiego Street), for PM2.5: -0.60 and -0.53 (Jana Pawła II Street) and for PM1.0 -0.40 and -0.59 (Jana Pawła II Street).
2017-03-06
WP-201317) Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non -volatile Particulate Matter (PM...Engine Volatile and Non -Volatile Particulate Matter (PM) Emissions 6. AUTHOR(S) E. Corporan, M. DeWitt, C. Klingshirn, M.D. Cheng, R. Miake-Lye, J. Peck...the performance and viability of two devices to condition aircraft turbine engine exhaust to allow the accurate measurement of total (volatile and non
Spatial Statistics of atmospheric particulate matter in China
NASA Astrophysics Data System (ADS)
Huang, Yongxiang; Wang, Yangjun; Liu, Yulu
2017-04-01
In this work, the spatial dynamics of the atmospheric particulate matters (resp. PM10 and PM2.5) are studied using turbulence methodologies. The hourly concentrations of particulate matter were released by the Chinese government (http://www.cnemc.cn). We first processed these data into daily average concentrations. Totally, there are 305 monitor stations with an observations period of 425 days. It is found experimentally that the spatial correlation function ρ(r) shows a log-law on the mesoscale range, i.e., 50 ≤ r ≤ 500 km, with an experimental scaling exponent β = 0.45. The spatial structure function shows a power-law behavior on the mesoscale range 90 ≤ r ≤ 500 km. The experimental scaling exponent ζ(q) is convex, showing that the intermittent correction is relevant in characterizing the spatial dynamics of particulate matter. The measured singularity spectrum f(α) also shows its multifractal nature. Experimentally, the particulate matter is more intermittent than the passive scalar, which could be partially due to the mesoscale movements of the atmosphere, and also due to local sources, such as local industry activities.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-16
... Ozone AGENCY: Environmental Protection Agency (EPA). ACTION: Withdrawal of direct final rule. SUMMARY... Particulate Matter and Ozone'' as a direct final rule on February 21, 2012. Because the EPA received adverse... Implementation Plans To Reduce Interstate Transport of Fine Particulate Matter and Ozone'' as a direct final rule...
Abstract
Epidemiological studies suggest an association between ambient particulate matter and cardiopulmonary diseases in humans. The mechanisms underlying these health effects are poorly understood. To better understand the potential relationship between particulate-ma...
40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...
40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...
40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...
40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...
40 CFR 52.528 - Control strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides and... strategy: Sulfur oxides and particulate matter. (a) In a letter dated October 10, 1986, the Florida... sulfur dioxide in the Everglades National Park. These plants must meet the 0.1#/MMBTU particulate limit...
NASA Astrophysics Data System (ADS)
Philip, Sajeev; Martin, Randall V.; Snider, Graydon; Weagle, Crystal L.; van Donkelaar, Aaron; Brauer, Michael; Henze, Daven K.; Klimont, Zbigniew; Venkataraman, Chandra; Guttikunda, Sarath K.; Zhang, Qiang
2017-04-01
Global measurements of the elemental composition of fine particulate matter across several urban locations by the Surface Particulate Matter Network reveal an enhanced fraction of anthropogenic dust compared to natural dust sources, especially over Asia. We develop a global simulation of anthropogenic fugitive, combustion, and industrial dust which, to our knowledge, is partially missing or strongly underrepresented in global models. We estimate 2-16 μg m-3 increase in fine particulate mass concentration across East and South Asia by including anthropogenic fugitive, combustion, and industrial dust emissions. A simulation including anthropogenic fugitive, combustion, and industrial dust emissions increases the correlation from 0.06 to 0.66 of simulated fine dust in comparison with Surface Particulate Matter Network measurements at 13 globally dispersed locations, and reduces the low bias by 10% in total fine particulate mass in comparison with global in situ observations. Global population-weighted PM2.5 increases by 2.9 μg m-3 (10%). Our assessment ascertains the urgent need of including this underrepresented fine anthropogenic dust source into global bottom-up emission inventories and global models.
Shuster-Meiseles, Timor; Shafer, Martin M; Heo, Jongbae; Pardo, Michal; Antkiewicz, Dagmara S; Schauer, James J; Rudich, Assaf; Rudich, Yinon
2016-04-01
In this study we investigated the possible causal role for soluble metal species extracted from roadway traffic emissions in promoting particulate matter (PM)-induced reactive oxygen species (ROS) production and antioxidant response element (ARE) promoter activation. To this end, these responses have been evaluated in alveolar macrophage and epithelial lung cells that have been exposed to 'Unfiltered', 'Filtered' and 'Filtered+Chelexed' water extracts of PM samples collected from the roadway urban environments of Thessaloniki, Milan and London. Except for Thessaloniki, our results demonstrate that filtration resulted in a minor decrease in ROS activity of the fine PM fraction, suggesting that ROS activity is attributed mainly to water-soluble PM species. In contrast to ROS, ARE activity was mediated predominantly by the water-soluble component of PM present in both the fine and coarse extracts. Further removal of metals by Chelex treatment from filtered water extracts showed that soluble metal species are the major factors mediating ROS and ARE activities of the soluble fraction, especially in the London PM extracts. Finally, utilizing step-wise multiple-regression analysis, we show that 87% and 78% of the total variance observed in ROS and ARE assays, respectively, is accounted for by changes in soluble metal concentration. Using a statistical analysis we find that As, Zn and Fe best predict the ROS-generating/ARE-activating capacity of the near roadway particulate matter in the pulmonary cells studied. Collectively, our findings imply that soluble metals present in roadside PM are potential drivers of both pro- and anti-oxidative effects of PM in respiratory tract. Copyright © 2016 Elsevier Inc. All rights reserved.
Electrostatic particle trap for ion beam sputter deposition
Vernon, Stephen P.; Burkhart, Scott C.
2002-01-01
A method and apparatus for the interception and trapping of or reflection of charged particulate matter generated in ion beam sputter deposition. The apparatus involves an electrostatic particle trap which generates electrostatic fields in the vicinity of the substrate on which target material is being deposited. The electrostatic particle trap consists of an array of electrode surfaces, each maintained at an electrostatic potential, and with their surfaces parallel or perpendicular to the surface of the substrate. The method involves interception and trapping of or reflection of charged particles achieved by generating electrostatic fields in the vicinity of the substrate, and configuring the fields to force the charged particulate material away from the substrate. The electrostatic charged particle trap enables prevention of charged particles from being deposited on the substrate thereby enabling the deposition of extremely low defect density films, such as required for reflective masks of an extreme ultraviolet lithography (EUVL) system.
Canada-United States Transboundary Particulate Matter Science Assessment
This 2004 document summarizes the findings of the Canada-U.S. subcommittee on Scientific Cooperation concerning the transboundary transport of particulate matter (PM) and PM precursors between the two countries.
Tavares, Fernanda Vasconcelos Fonseca; Ardisson, José Domingos; Rodrigues, Paulo César Horta; Fabris, José Domingos; Fernandez-Outon, Luis Eugenio; Feliciano, Vanusa Maria Delage
2017-08-01
Samples of soil, iron ore, and airborne particulate matter (size <10 μm) were analyzed with the main goal of investigating the differentiating physicochemical properties of their ferruginous compounds. These data were used to identify whether the sources of airborne particulate matter in the metropolitan area of Belo Horizonte, Minas Gerais, Brazil, are either from natural origin, as, for instance, re-suspension of particles from soil, or due to anthropogenic activities, meaning that it would be originated from the many iron ore minings surrounding the metropolitan area. Numerical simulations were used to model the atmospheric dispersion of the airborne particulate matter emitted by iron mining located at the Iron Quadrangle geodomain, Minas Gerais. Results from these numerical simulations supported identifying the sites with the highest concentrations of airborne particulate matter in the metropolitan area. Samples of these suspended materials were collected at the selected sites by using high-volume air samplers. The physicochemical features of the solid materials were assessed by X-ray fluorescence, X-ray diffraction, magnetometry, and 57 Fe Mössbauer spectroscopy. The soil materials were found to be rich in quartz, aluminum, organic matter, and low contents of iron, mainly as low crystalline iron oxides. The samples of the iron ores, on the other hand, contain high concentration of iron, dominantly as relatively pure and crystalline hematite (α-Fe 2 O 3 ). The samples of the airborne particulate matter are rich in iron, mainly as hematite, but contained also quartz, aluminum, and calcium. Mössbauer spectroscopy was used to evaluate the hyperfine structure of 57 Fe of the hematite both from the iron ore and the soil samples. The structural characteristics of the hematite of these particulate materials were further explored. The direct influence of the iron ore mining on the composition of the airborne particulate matter was clearly evidenced based on the trace ability of hematite to its source of emission. Even the atmospheric air on regions relatively far away from the mining activities is also significantly influenced.
Investigation into pedestrian exposure to near-vehicle exhaust emissions
2009-01-01
Background Inhalation of diesel particulate matter (DPM) is known to have a negative impact on human health. Consequently, there are regulations and standards that limit the maximum concentrations to which persons may be exposed and the maximum concentrations allowed in the ambient air. However, these standards consider steady exposure over large spatial and time scales. Due to the nature of many vehicle exhaust systems, pedestrians in close proximity to a vehicle's tailpipe may experience events where diesel particulate matter concentrations are high enough to cause acute health effects for brief periods of time. Methods In order to quantify these exposure events, instruments which measure specific exhaust constituent concentrations were placed near a roadway and connected to the mouth of a mannequin used as a pedestrian surrogate. By measuring concentrations at the mannequin's mouth during drive-by events with a late model diesel truck, a representative estimate of the exhaust constituent concentrations to which a pedestrian may be exposed was obtained. Typical breathing rates were then multiplied by the measured concentrations to determine the mass of pollutant inhaled. Results The average concentration of diesel particulate matter measured over the duration of a single drive-by test often exceeded the low concentrations used in human clinical studies which are known to cause acute health effects. It was also observed that higher concentrations of diesel particulate matter were measured at the height of a stroller than were measured at the mouth of a mannequin. Conclusion Diesel particulate matter concentrations during drive-by incidents easily reach or exceed the low concentrations that can cause acute health effects for brief periods of time. For the case of a particularly well-tuned late-model year vehicle, the mass of particulate matter inhaled during a drive-by incident is small compared to the mass inhaled daily at ambient conditions. On a per breath basis, however, the mass of particulate matter inhaled is large compared to the mass inhaled at ambient conditions. Finally, it was determined that children, infants, or people breathing at heights similar to that of a passing vehicle's tailpipe may be exposed to higher concentrations of particulate matter than those breathing at higher locations, such as adults standing up. PMID:19331669
EMAT enhanced dispersion of particles in liquid
Kisner, Roger A.; Rios, Orlando; Melin, Alexander M.; Ludtka, Gerard Michael; Ludtka, Gail Mackiewicz; Wilgen, John B.
2016-11-29
Particulate matter is dispersed in a fluid material. A sample including a first material in a fluid state and second material comprising particulate matter are placed into a chamber. The second material is spatially dispersed in the first material utilizing EMAT force. The dispersion process continues until spatial distribution of the second material enables the sample to meet a specified criterion. The chamber and/or the sample is electrically conductive. The EMAT force is generated by placing the chamber coaxially within an induction coil driven by an applied alternating current and placing the chamber and induction coil coaxially within a high field magnetic. The EMAT force is coupled to the sample without physical contact to the sample or to the chamber, by another physical object. Batch and continuous processing are utilized. The chamber may be folded within the bore of the magnet. Acoustic force frequency and/or temperature may be controlled.
40 CFR 60.285 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... determine compliance with the particulate matter standards in § 60.282(a) (1) and (3) as follows: (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample... opacity. (c) The owner or operator shall determine compliance with the particular matter standard in § 60...
40 CFR 60.285 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... determine compliance with the particulate matter standards in § 60.282(a) (1) and (3) as follows: (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample... opacity. (c) The owner or operator shall determine compliance with the particular matter standard in § 60...
40 CFR 60.285 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... determine compliance with the particulate matter standards in § 60.282(a) (1) and (3) as follows: (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample... opacity. (c) The owner or operator shall determine compliance with the particular matter standard in § 60...
40 CFR 60.285 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determine compliance with the particulate matter standards in § 60.282(a) (1) and (3) as follows: (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample... opacity. (c) The owner or operator shall determine compliance with the particular matter standard in § 60...
40 CFR 60.2155 - May I conduct performance testing less often?
Code of Federal Regulations, 2010 CFR
2010-07-01
... pollutant (particulate matter, hydrogen chloride, or opacity) over 3 consecutive years show that you comply... limitation for particulate matter, hydrogen chloride, or opacity, you may choose to conduct performance tests... matter, hydrogen chloride, or opacity, you must conduct annual performance tests for that pollutant until...
Students' Understanding of the Particulate Nature of Matter
ERIC Educational Resources Information Center
Singer, Jonathan E.; Tal, Revital; Wu, Hsin-Kai
2003-01-01
The particulate nature of matter is identified in science education standards as one of the fundamental concepts that students should understand at the middle school level. However, science education research in indicates that secondary school students have difficulties understanding the structure of matter. The purpose of the study is to describe…
Population exposure to ambient particulate matter (PM) has received considerable attention due to the association between ambient particulate concentrations and mortality. Current toxicological and epidemiological studies and controlled human and animal exposures suggest that a...
40 CFR 52.578 - Control Strategy: Sulfur oxides and particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control Strategy: Sulfur oxides and... Strategy: Sulfur oxides and particulate matter. Link to an amendment published at 76 FR 31859, June 2, 2011... user, the added text is set forth as follows: § 52.578 Control Strategy: Sulfur oxides and particulate...
Canada-United States Transboundary Particulate Matter Science Assessment 2013
This 2013 document summarizes the findings of the Canada-U.S. subcommittee on Scientific Cooperation concerning the transboundary transport of particulate matter (PM) and PM precursors between the two countries.
ADVANCES IN CONTROL OF PM2..5 AND PM2..5 PRECURSORS GENERATED BY THE COMBUSTION OF PULVERIZED COAL
Particulate matter smaller than 2.5 micrometers in aerodynamic diameter (PM2.5) is of concern due to adverse health effects associated with elevated ambient mass concentrations of PM2.5. PM2.5 from coal-fired utility boilers is composed of directly emitted (primary) particles and...
40 CFR 60.42 - Standard for particulate matter (PM).
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fossil-Fuel-Fired Steam Generators for Which Construction Is Commenced After August 17, 1971 § 60.42... PM in excess of 43 nanograms per joule (ng/J) heat input (0.10 lb/MMBtu) derived from fossil fuel or fossil fuel and wood residue. (2) Exhibit greater than 20 percent opacity except for one six-minute...
40 CFR 60.42 - Standard for particulate matter (PM).
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fossil-Fuel-Fired Steam Generators for Which Construction Is Commenced After August 17, 1971 § 60.42... PM in excess of 43 nanograms per joule (ng/J) heat input (0.10 lb/MMBtu) derived from fossil fuel or fossil fuel and wood residue. (2) Exhibit greater than 20 percent opacity except for one six-minute...
This paper addresses the need for detailed chemical information on the fine particulate matter (PM2.5) generated by commercial aviation engines. The exhaust plumes of nine engine models were sampled during the three test campaigns of the Aircraft Particle Emissions eXperiment (AP...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
... Administrative Code, and it modifies the sulfur dioxide (SO 2 ) mass emissions limit associated with Conectiv... and the estimate of future operations using the low sulfur (0.5%) residual fuel to generate..., Particulate matter, Sulfur oxides. Authority: 42 U.S.C. 7401 et seq. Dated: December 17, 2009. James W. Newsom...
USDA-ARS?s Scientific Manuscript database
Moisture is paramount to cotton fiber properties dictating harvesting, ginning, storage and spinning as well as others. Currently, oven drying in air is often utilized to generate the percentage of moisture in cotton fibers. Karl Fischer Titration another method for cotton moisture, has been compa...
Leachable transition metals are considered to be important mediators in the biological effects of ambient particulate matter (PM) and model particles such as oil-fly ashes (OFA). We determined metal driven Fenton activity in 10 OFA in the presence of hydrogen peroxide using elect...
40 CFR 52.1920 - Identification of plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Allowable particulate matter emission rates from combined wood fuel and fossil fuel fired steam generating... 7709 Subsection (o) only. 595:20-3-42 Responsibility for signs, forms, etc. 05/26/1994 02/29/1996 61 FR... 05/26/1994 02/29/1996 61 FR 7709 Subsection (a) only. 595:20-7-3 Rejection receipt—Form VID 44 05/26...
40 CFR 52.1920 - Identification of plan.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Allowable particulate matter emission rates from combined wood fuel and fossil fuel fired steam generating... 7709 Subsection (o) only. 595:20-3-42 Responsibility for signs, forms, etc. 05/26/1994 02/29/1996 61 FR... 05/26/1994 02/29/1996 61 FR 7709 Subsection (a) only. 595:20-7-3 Rejection receipt—Form VID 44 05/26...
Plasma discharge self-cleaning filtration system
Cho, Young I.; Fridman, Alexander; Gutsol, Alexander F.; Yang, Yong
2014-07-22
The present invention is directed to a novel method for cleaning a filter surface using a plasma discharge self-cleaning filtration system. The method involves utilizing plasma discharges to induce short electric pulses of nanoseconds duration at high voltages. These electrical pulses generate strong Shockwaves that disintegrate and dislodge particulate matter located on the surface of the filter.
NASA Astrophysics Data System (ADS)
Mukherjee, A. D.; Brown, S. G.; McCarthy, M. C.
2017-12-01
A new generation of low cost air quality sensors have the potential to provide valuable information on the spatial-temporal variability of air pollution - if the measurements have sufficient quality. This study examined the performance of a particulate matter sensor model, the AirBeam (HabitatMap Inc., Brooklyn, NY), over a three month period in the urban environment of Sacramento, California. Nineteen AirBeam sensors were deployed at a regulatory air monitoring site collocated with meteorology measurements and as a local network over an 80 km2 domain in Sacramento, CA. This study presents the methodology to evaluate the precision, accuracy, and reliability of the sensors over a range of meteorological and aerosol conditions. The sensors demonstrated a robust degree of precision during collocated measurement periods (R2 = 0.98 - 0.99) and a moderate degree of correlation against a Beta Attenuation Monitor PM2.5 monitor (R2 0.6). A normalization correction is applied during the study period so that each AirBeam sensor in the network reports a comparable value. The role of the meteorological environment on the accuracy of the sensor measurements is investigated, along with the possibility of improving the measurements through a meteorology weighted correction. The data quality of the network of sensors is examined, and the spatial variability of particulate matter through the study domain derived from the sensor network is presented.
Grain Elevators: New Source Performance Standards (NSPS)
The New Source Performance Standards (NSPS) for Grain Elevators aims to reduce particulate matter pollution. The new amendments seek to clarify definitions, and requirements, as well as propose new regulations on particulate matter emissions
Borrok, D.M.; Gieré, R.; Ren, M.; Landa, E.R.
2010-01-01
Atmospheric Zn emissions from the burning of coal and tire-derived fuel (TDF) for power generation can be considerable. In an effort to lay the foundation for tracking these contributions, we evaluated the Zn isotopes of coal, a mixture of 95 wt % coal + 5 wt % TDF, and the particulate matter (PM) derived from their combustion in a power-generating plant. The average Zn concentrations and δ(66)Zn were 36 mg/kg and 183 mg/kg and +0.24‰ and +0.13‰ for the coal and coal + TDF, respectively. The δ(66)Zn of the PM sequestered in the cyclone-type mechanical separator was the lightest measured, -0.48‰ for coal and -0.81‰ for coal+TDF. The δ(66)Zn of the PM from the electrostatic precipitator showed a slight enrichment in the heavier Zn isotopes relative to the starting material. PM collected from the stack had the heaviest δ(66)Zn in the system, +0.63‰ and +0.50‰ for the coal and coal + TDF, respectively. Initial fractionation during the generation of a Zn-rich vapor is followed by temperature-dependent fractionation as Zn condenses onto the PM. The isotopic changes of the two fuel types are similar, suggesting that their inherent chemical differences have only a secondary impact on the isotopic fractionation process.
Borrok, David M; Gieré, Reto; Ren, Minghua; Landa, Edward R
2010-12-01
Atmospheric Zn emissions from the burning of coal and tire-derived fuel (TDF) for power generation can be considerable. In an effort to lay the foundation for tracking these contributions, we evaluated the Zn isotopes of coal, a mixture of 95 wt % coal + 5 wt % TDF, and the particulate matter (PM) derived from their combustion in a power-generating plant. The average Zn concentrations and δ(66)Zn were 36 mg/kg and 183 mg/kg and +0.24‰ and +0.13‰ for the coal and coal + TDF, respectively. The δ(66)Zn of the PM sequestered in the cyclone-type mechanical separator was the lightest measured, -0.48‰ for coal and -0.81‰ for coal+TDF. The δ(66)Zn of the PM from the electrostatic precipitator showed a slight enrichment in the heavier Zn isotopes relative to the starting material. PM collected from the stack had the heaviest δ(66)Zn in the system, +0.63‰ and +0.50‰ for the coal and coal + TDF, respectively. Initial fractionation during the generation of a Zn-rich vapor is followed by temperature-dependent fractionation as Zn condenses onto the PM. The isotopic changes of the two fuel types are similar, suggesting that their inherent chemical differences have only a secondary impact on the isotopic fractionation process.
NASA Astrophysics Data System (ADS)
Lungu, Mihai; Lungu, Antoanetta; Stefu, Nicoleta; Neculae, Adrian; Strambeanu, Nicolae
2017-01-01
Air pollution is known to have many adverse effects, among which those on human health are considered the most important. Healthy people of all ages can be adversely affected by high levels of air pollutants. Nanoparticles can be considered among the most harmful of all pollutants as they can penetrate straight into the lungs and blood stream. Their role in the aging process has also recently been revealed. In Romania, practically in all important urban areas (Bucureşti, Iaşi, Timişoara, Braşov, Baia Mare, etc.) the daily limit values for airborne particulate matter are exceeded, so more efforts in controlling air quality are required, along with more research and policies with positive impact on reducing the pollutants concentration in air. The approaches that have been developed to assess the air quality and health impacts of pollution sources are based on analytical methods such as source apportionment, factor analyses, and the measurement of source-relevant indicator compounds. The goal of the present study is to offer preliminary but relevant information on the particulate matter distribution in the city of Timisoara, Romania. Measurements of inhalable coarse and fine particles in two areas of the city, the most affected by industrial particulate emissions, were performed in days with various meteorological conditions. Meteorological parameters for the specific measurement days were recorded (wind speed and direction, humidity, temperature, pressure, etc.) and the influence of these parameters on the particulate matter dispersion was studied. The results show that the meteorological conditions cause differences between airborne particulate matter distributions in different days in the same zones. Measurements were made in northern and southern areas of the city of Timisoara because previous results have shown high levels of airborne particulate matter in these areas.
The heart as an extravascular target of endothelin-1 in ...
Exposure to particulate matter air pollution has been causally linked to cardiovascular disease in humans. Several broad and overlapping hypotheses describing the biological mechanisms by which particulate matter exposure leads to cardiovascular disease and cardiac dysfunction have been explored, though linkage with specific factors or genes remains limited. Given evidence pointing to autocrine/paracrine signaling systems as modulators of cardiac dysfunction, the present review highlights the emerging role of endothelins as mediators of cardiac dysfunction following particulate matter exposure. Endothelin-1 is a small multifunctional protein expressed in the pulmonary and cardiovascular system, known for its ability to constrict blood vessels. Although endothelin-1 can also directly and indirectly (via secondary signaling events) modulate cardiac contractility, heart rate, and rhythm, research on the role of endothelins in the context of air pollution has tended to focus on the vascular effects. The plausibility of endothelin as a mechanism underlying particulate matter-induced cardiac dysfunction is further supported by the therapeutic utility of certain endothelin receptor antagonists. Extravascular effects of endothelin on the heart could better explain one mechanism by which particulate matter exposure may lead to cardiac dysfunction. We propose and support the novel hypothesis that autocrine/paracrine signaling systems, such as endothelins, mediate cardiac
Carbonaceous aerosols in fine particulate matter of Santiago Metropolitan Area, Chile.
Toro Araya, Richard; Flocchini, Robert; Morales Segura, Rául G E; Leiva Guzmán, Manuel A
2014-01-01
Measurements of carbonaceous aerosols in South American cities are limited, and most existing data are of short term and limited to only a few locations. For 6 years (2002-2007), concentrations of fine particulate matter and organic and elemental carbon were measured continuously in the capital of Chile. The contribution of carbonaceous aerosols to the primary and secondary fractions was estimated at three different sampling sites and in the warm and cool seasons. The results demonstrate that there are significant differences in the levels in both the cold (March to August) and warm (September to February) seasons at all sites studied. The percent contribution of total carbonaceous aerosol fine particulate matter was greater in the cool season (53 ± 41%) than in the warm season (44 ± 18%). On average, the secondary organic carbon in the city corresponded to 29% of the total organic carbon. In cold periods, this proportion may reach an average of 38%. A comparison of the results with the air quality standards for fine particulate matter indicates that the total carbonaceous fraction alone exceeds the World Health Organization standard (10 µg/m(3)) and the United States Environmental Protection Agency standard (15 µg/m(3)) for fine particulate matter.
Apparatus for particulate matter analysis
Gundel, Lara A.; Apte, Michael G.; Hansen, Anthony D.; Black, Douglas R.
2007-01-30
The apparatus described herein is a miniaturized system for particle exposure assessment (MSPEA) for the quantitative measurement and qualitative identification of particulate content in gases. The present invention utilizes a quartz crystal microbalance (QCM) or other mass-sensitive temperature compensated acoustic wave resonator for mass measurement. Detectors and probes and light sources are used in combination for the qualitative determination of particulate matter.
The Detroit Exposure and Aerosol Research Study (DEARS) provided data to compare outdoor residential coarse particulate matter (PM10-2.5) concentrations in six different areas of Detroit with data from a central monitoring site. Daily and seasonal influences on the spa...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-21
... Matter and Ozone AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY: EPA is...: Interstate Transport of Fine Particulate Matter and Ozone and Correction of SIP Approvals, published August 8... ) and sulfur dioxide (SO 2 ) that contribute harmful levels of fine particle matter and ozone in...
Representations of Fundamental Chemistry Concepts in Relation to the Particulate Nature of Matter
ERIC Educational Resources Information Center
Kirbulut, Zubeyde Demet; Beeth, Michael Edward
2013-01-01
This study investigated high school students' understanding of fundamental chemistry concepts - states of matter, melting, evaporation, condensation, boiling, and vapor pressure, in relation to their understanding of the particulate nature of matter. A sample of six students (four females and two males) enrolled in a second year chemistry course…
Representations of Fundamental Chemistry Concepts in Relation to the Particulate Nature of Matter
ERIC Educational Resources Information Center
Kirbulut, Zübeyde Demet; Beeth, Michael Edward
2013-01-01
This study investigated high school students' understanding of fundamental chemistry concepts--states of matter, melting, evaporation, condensation, boiling, and vapor pressure, in relation to their understanding of the particulate nature of matter. A sample of six students (four females and two males) enrolled in a second year chemistry course at…
Summary of Ambient Air Monitoring in Southeast Chicago - Oct. 28, 2013
The monitoring station at George Washington High School reports pollutants including fine particulate matter, inhalable particulate matter, lead, and toxic metals. Data suggests sources including Beemsterboer and KCBX petcoke (petroleum coke) facilities.