Sample records for passing

  1. 78 FR 62344 - Sabine Pass Liquefaction Expansion, LLC, Sabine Pass Liquefaction, LLC, and Sabine Pass LNG, L.P...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-18

    .... CP13-553-000] Sabine Pass Liquefaction Expansion, LLC, Sabine Pass Liquefaction, LLC, and Sabine Pass... 30, 2013, Sabine Pass Liquefaction Expansion, LLC, Sabine Pass Liquefaction, LLC, and Sabine Pass LNG, L.P. (collectively referred to as Sabine Pass) filed with the Federal Energy Regulatory Commission...

  2. Creep Deformation and Rupture Behavior of Single- and Dual-Pass 316LN Stainless-Steel-Activated TIG Weld Joints

    NASA Astrophysics Data System (ADS)

    Vijayanand, V. D.; Vasudevan, M.; Ganesan, V.; Parameswaran, P.; Laha, K.; Bhaduri, A. K.

    2016-06-01

    Creep deformation and rupture behavior of single-pass and dual-pass 316LN stainless steel (SS) weld joints fabricated by an autogenous activated tungsten inert gas welding process have been assessed by performing metallography, hardness, and conventional and impression creep tests. The fusion zone of the single-pass joint consisted of columnar zones adjacent to base metals with a central equiaxed zone, which have been modified extensively by the thermal cycle of the second pass in the dual-pass joint. The equiaxed zone in the single-pass joint, as well as in the second pass of the dual-pass joint, displayed the lowest hardness in the joints. In the dual-pass joint, the equiaxed zone of the first pass had hardness comparable to the columnar zone. The hardness variations in the joints influenced the creep deformation. The equiaxed and columnar zone in the first pass of the dual-pass joint was more creep resistant than that of the second pass. Both joints possessed lower creep rupture life than the base metal. However, the creep rupture life of the dual-pass joint was about twofolds more than that of the single-pass joint. Creep failure in the single-pass joint occurred in the central equiaxed fusion zone, whereas creep cavitation that originated in the second pass was blocked at the weld pass interface. The additional interface and strength variation between two passes in the dual-pass joint provides more restraint to creep deformation and crack propagation in the fusion zone, resulting in an increase in the creep rupture life of the dual-pass joint over the single-pass joint. Furthermore, the differences in content, morphology, and distribution of delta ferrite in the fusion zone of the joints favors more creep cavitation resistance in the dual-pass joint over the single-pass joint with the enhancement of creep rupture life.

  3. Passing and Catching in Rugby.

    ERIC Educational Resources Information Center

    Namudu, Mike M.

    This booklet contains the fundamentals for rugby at the primary school level. It deals primarily with passing and catching the ball. It contains instructions on (1) holding the ball for passing, (2) passing the ball to the left--standing, (3) passing the ball to the left--running, (4) making a switch pass, (5) the scrum half's normal pass, (6) the…

  4. Two antenna, two pass interferometric synthetic aperture radar

    DOEpatents

    Martinez, Ana; Doerry, Armin W.; Bickel, Douglas L.

    2005-06-28

    A multi-antenna, multi-pass IFSAR mode utilizing data driven alignment of multiple independent passes can combine the scaling accuracy of a two-antenna, one-pass IFSAR mode with the height-noise performance of a one-antenna, two-pass IFSAR mode. A two-antenna, two-pass IFSAR mode can accurately estimate the larger antenna baseline from the data itself and reduce height-noise, allowing for more accurate information about target ground position locations and heights. The two-antenna, two-pass IFSAR mode can use coarser IFSAR data to estimate the larger antenna baseline. Multi-pass IFSAR can be extended to more than two (2) passes, thereby allowing true three-dimensional radar imaging from stand-off aircraft and satellite platforms.

  5. The US Navy Coastal Surge and Inundation Prediction System (CSIPS): Making Forecasts Easier

    DTIC Science & Technology

    2013-02-14

    produced the best results Peak Water Level Percent Error CD Formulation LAWMA , Amerada Pass Freshwater Canal Locks Calcasieu Pass Sabine Pass...Conclusions Ongoing Work 16 Baseline Simulation Results Peak Water Level Percent Error LAWMA , Amerada Pass Freshwater Canal Locks Calcasieu Pass...Conclusions Ongoing Work 20 Sensitivity Studies Waves Run Water Level – Percent Error of Peak HWM MAPE Lawma , Armeda Pass Freshwater

  6. Assessing the efficacy of single-pass backpack electrofishing to characterize fish community structure

    USGS Publications Warehouse

    Meador, M.R.; McIntyre, J.P.; Pollock, K.H.

    2003-01-01

    Two-pass backpack electrofishing data collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program were analyzed to assess the efficacy of single-pass backpack electrofishing. A two-capture removal model was used to estimate, within 10 river basins across the United States, proportional fish species richness from one-pass electrofishing and probabilities of detection for individual fish species. Mean estimated species richness from first-pass sampling (ps1) ranged from 80.7% to 100% of estimated total species richness for each river basin, based on at least seven samples per basin. However, ps1 values for individual sites ranged from 40% to 100% of estimated total species richness. Additional species unique to the second pass were collected in 50.3% of the samples. Of these, cyprinids and centrarchids were collected most frequently. Proportional fish species richness estimated for the first pass increased significantly with decreasing stream width for 1 of the 10 river basins. When used to calculate probabilities of detection of individual fish species, the removal model failed 48% of the time because the number of individuals of a species was greater in the second pass than in the first pass. Single-pass backpack electrofishing data alone may make it difficult to determine whether characterized fish community structure data are real or spurious. The two-pass removal model can be used to assess the effectiveness of sampling species richness with a single electrofishing pass. However, the two-pass removal model may have limited utility to determine probabilities of detection of individual species and, thus, limit the ability to assess the effectiveness of single-pass sampling to characterize species relative abundances. Multiple-pass (at least three passes) backpack electrofishing at a large number of sites may not be cost-effective as part of a standardized sampling protocol for large-geographic-scale studies. However, multiple-pass electrofishing at some sites may be necessary to better evaluate the adequacy of single-pass electrofishing and to help make meaningful interpretations of fish community structure.

  7. Spanish validation of the Premorbid Adjustment Scale (PAS-S).

    PubMed

    Barajas, Ana; Ochoa, Susana; Baños, Iris; Dolz, Montse; Villalta-Gil, Victoria; Vilaplana, Miriam; Autonell, Jaume; Sánchez, Bernardo; Cervilla, Jorge A; Foix, Alexandrina; Obiols, Jordi E; Haro, Josep Maria; Usall, Judith

    2013-02-01

    The Premorbid Adjustment Scale (PAS) has been the most widely used scale to quantify premorbid status in schizophrenia, coming to be regarded as the gold standard of retrospective assessment instruments. To examine the psychometric properties of the Spanish version of the PAS (PAS-S). Retrospective study of 140 individuals experiencing a first episode of psychosis (n=77) and individuals who have schizophrenia (n=63), both adult and adolescent patients. Data were collected through a socio-demographic questionnaire and a battery of instruments which includes the following scales: PAS-S, PANSS, LSP, GAF and DAS-sv. The Cronbach's alpha was performed to assess the internal consistency of PAS-S. Pearson's correlations were performed to assess the convergent and discriminant validity. The Cronbach's alpha of the PAS-S scale was 0.85. The correlation between social PAS-S and total PAS-S was 0.85 (p<0.001); while for academic PAS-S and total PAS-S it was 0.53 (p<0.001). Significant correlations were observed between all the scores of each age period evaluated across the PAS-S scale, with a significance value less than 0.001. There was a relationship between negative symptoms and social PAS-S (0.20, p<0.05) and total PAS-S (0.22, p<0.05), but not with academic PAS-S. However, there was a correlation between academic PAS-S and general subscale of the PANSS (0.19, p<0.05). Social PAS-S was related to disability measures (DAS-sv); and academic PAS-S showed discriminant validity with most of the variables of social functioning. PAS-S did not show association with the total LSP scale (discriminant validity). The Spanish version of the Premorbid Adjustment Scale showed appropriate psychometric properties in patients experiencing a first episode of psychosis and who have a chronic evolution of the illness. Moreover, each domain of the PAS-S (social and academic premorbid functioning) showed a differential relationship to other characteristics such as psychotic symptoms, disability or social functioning after onset of illness. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. SEAHT: A computer program for the use of intersecting arcs of altimeter data for sea surface height refinement

    NASA Technical Reports Server (NTRS)

    Allen, C. P.; Martin, C. F.

    1977-01-01

    The SEAHT program is designed to process multiple passes of altimeter data with intersecting ground tracks, with the estimation of corrections for orbital errors to each pass such that the data has the best overall agreement at the crossover points. Orbit error for each pass is modeled as a polynomial in time, with optional orders of 0, 1, or 2. One or more passes may be constrained in the adjustment process, thus allowing passes with the best orbits to provide the overall level and orientation of the estimated sea surface heights. Intersections which disagree by more than an input edit level are not used in the error parameter estimation. In the program implementation, passes are grouped into South-North passes and North-South passes, with the North-South passes partitioned out for the estimation of orbit error parameters. Computer core utilization is thus dependent on the number of parameters estimated for the set of South-North arcs, but is independent on the number of North-South passes. Estimated corrections for each pass are applied to the data at its input data rate and an output tape is written which contains the corrected data.

  9. Evaluation of Dynamic Passing Sight Distance Problem Using a Finite Element Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Xuedong; Radwan, Essam; Zhang, Fan

    2008-06-01

    Sufficient passing sight distance is an important control for two-lane rural highway design to minimize the possibility of a head-on collision between passing and opposing vehicles. Traditionally, passing zones are marked by checking passing sight distance that is potentially restricted by static sight obstructions. Such obstructions include crest curves, overpasses, and lateral objects along highways. This paper proposes a new concept of dynamic sight-distance assessment, which involves restricted passing sight distances due to the impeding vehicles that are traveling in the same direction. Using a finite-element model, the dynamic passing sight-distance problem was evaluated, and the writers analyzed the relationshipsmore » between the available passing sight distance and other factors such as the horizontal curve radius, impeding vehicle dimensions, and a driver s following distance. It was found that the impeding vehicles may cause substantially insufficient passing sight distances, which may lead to potential traffic safety problems. It is worthwhile to expand on this safety issue and consider the dynamic passing sight distance in highway design.« less

  10. Method for optimizing output in ultrashort-pulse multipass laser amplifiers with selective use of a spectral filter

    DOEpatents

    Backus, Sterling J [Erie, CO; Kapteyn, Henry C [Boulder, CO

    2007-07-10

    A method for optimizing multipass laser amplifier output utilizes a spectral filter in early passes but not in later passes. The pulses shift position slightly for each pass through the amplifier, and the filter is placed such that early passes intersect the filter while later passes bypass it. The filter position may be adjust offline in order to adjust the number of passes in each category. The filter may be optimized for use in a cryogenic amplifier.

  11. 78 FR 62657 - Proposed Information Collection; The Interagency Access Pass and Senior Pass Application Processes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... issued to U.S. citizens or permanent residents who are 62 years or older. There is a $10 fee for the... Information Collection; The Interagency Access Pass and Senior Pass Application Processes AGENCY: National... Service. The passes provide U.S. citizens and visitors an affordable and convenient way to access Federal...

  12. 75 FR 68347 - Sabine Pass Liquefaction LLC, and Sabine Pass LNG, L.P.; Notice of Intent To Prepare an...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-05

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF10-24-000] Sabine Pass Liquefaction LLC, and Sabine Pass LNG, L.P.; Notice of Intent To Prepare an Environmental Assessment for the Planned Sabine Pass Liquefaction Project and Request for Comments on Environmental Issues October 29, 2010...

  13. Ultrastructural evaluation of multiple pass low energy versus single pass high energy radio-frequency treatment.

    PubMed

    Kist, David; Burns, A Jay; Sanner, Roth; Counters, Jeff; Zelickson, Brian

    2006-02-01

    The radio-frequency (RF) device is a system capable of volumetric heating of the mid to deep dermis and selective heating of the fibrous septa strands and fascia layer. Clinically, these effects promote dermal collagen production, and tightening of these deep subcutaneous structures. A new technique of using multiple low energy passes has been described which results in lower patient discomfort and fewer side effects. This technique has also been anecdotally described as giving more reproducible and reliable clinical results of tissue tightening and contouring. This study will compare ultrastructural changes in collagen between a single pass high energy versus up to five passes of a multiple pass lower energy treatment. Three subjects were consented and treated in the preauricular region with the RF device using single or multiple passes (three or five) in the same 1.5 cm(2) treatment area with a slight delay between passes to allow tissue cooling. Biopsies from each treatment region and a control biopsy were taken immediately, 24 hours or 6 months post treatment for electron microscopic examination of the 0-1 mm and 1-2 mm levels. Sections of tissue 1 mm x 1 mm x 80 nm were examined with an RCA EMU-4 Transmission Electron Microscope. Twenty sections from 6 blocks from each 1 mm depth were examined by 2 blinded observers. The morphology and degree of collagen change in relation to area examined was compared to the control tissue, and estimated using a quantitative scale. Ultrastructural examination of tissue showed that an increased amount of collagen fibril changes with increasing passes at energies of 97 J (three passes) and 122 J (five passes), respectively. The changes seen after five multiple passes were similar to those detected after much more painful single pass high-energy treatments. This ultrastructural study shows changes in collagen fibril morphology with an increased effect demonstrated at greater depths of the skin with multiple low-fluence passes and at lesser depths with single pass higher fluence settings. Findings suggest that similar collagen fibril alteration can occur with multiple pass low-energy treatments and single pulse high-energy treatments. The lower fluence multiple pass approach is associated with less patient discomfort, less side effects, and more consistent clinical results. Copyright 2005 Wiley-Liss, Inc.

  14. Simulation of double-pass stimulated Raman backscattering

    NASA Astrophysics Data System (ADS)

    Wu, Z.; Chen, Q.; Morozov, A.; Suckewer, S.

    2018-04-01

    Experiments on Stimulated Raman Backscattering (SRBS) in plasma have demonstrated significantly higher energy conversion in a double-pass amplifier where the laser pulses go through the plasma twice compared with a single-pass amplifier with double the plasma length of a single pass. In this paper, the improvement in understanding recent experimental results is presented by considering quite in detail the effects of plasma heating on the modeling of SRBS. Our simulation results show that the low efficiency of single-pass amplifiers can be attributed to Landau damping and the frequency shift of Langmuir waves. In double-pass amplifiers, these issues can be avoided, to some degree, because pump-induced heating could be reduced, while the plasma cools down between the passes. Therefore, double-pass amplifiers yield considerably enhanced energy transfer from the pump to the seed, hence the output pulse intensity.

  15. First results of electron temperature measurements by the use of multi-pass Thomson scattering system in GAMMA 10

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshikawa, M., E-mail: yosikawa@prc.tsukuba.ac.jp; Nagasu, K.; Shimamura, Y.

    2014-11-15

    A multi-pass Thomson scattering (TS) has the advantage of enhancing scattered signals. We constructed a multi-pass TS system for a polarisation-based system and an image relaying system modelled on the GAMMA 10 TS system. We undertook Raman scattering experiments both for the multi-pass setting and for checking the optical components. Moreover, we applied the system to the electron temperature measurements in the GAMMA 10 plasma for the first time. The integrated scattering signal was magnified by approximately three times by using the multi-pass TS system with four passes. The electron temperature measurement accuracy is improved by using this multi-pass system.

  16. First results of electron temperature measurements by the use of multi-pass Thomson scattering system in GAMMA 10.

    PubMed

    Yoshikawa, M; Yasuhara, R; Nagasu, K; Shimamura, Y; Shima, Y; Kohagura, J; Sakamoto, M; Nakashima, Y; Imai, T; Ichimura, M; Yamada, I; Funaba, H; Kawahata, K; Minami, T

    2014-11-01

    A multi-pass Thomson scattering (TS) has the advantage of enhancing scattered signals. We constructed a multi-pass TS system for a polarisation-based system and an image relaying system modelled on the GAMMA 10 TS system. We undertook Raman scattering experiments both for the multi-pass setting and for checking the optical components. Moreover, we applied the system to the electron temperature measurements in the GAMMA 10 plasma for the first time. The integrated scattering signal was magnified by approximately three times by using the multi-pass TS system with four passes. The electron temperature measurement accuracy is improved by using this multi-pass system.

  17. 40 CFR 205.171-8 - Passing or failing under SEA.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Passing or failing under SEA. 205.171... Passing or failing under SEA. (a) A failing exhaust system is one which, when installed on any motorcycle... equal to the number in Column A, the sample passes. (c) Pass or failure of a SEA takes place when a...

  18. 40 CFR 205.171-8 - Passing or failing under SEA.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Passing or failing under SEA. 205.171... Passing or failing under SEA. (a) A failing exhaust system is one which, when installed on any motorcycle... equal to the number in Column A, the sample passes. (c) Pass or failure of a SEA takes place when a...

  19. 40 CFR 205.171-8 - Passing or failing under SEA.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Passing or failing under SEA. 205.171... Passing or failing under SEA. (a) A failing exhaust system is one which, when installed on any motorcycle... equal to the number in Column A, the sample passes. (c) Pass or failure of a SEA takes place when a...

  20. 40 CFR 205.171-8 - Passing or failing under SEA.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Passing or failing under SEA. 205.171... Passing or failing under SEA. (a) A failing exhaust system is one which, when installed on any motorcycle... equal to the number in Column A, the sample passes. (c) Pass or failure of a SEA takes place when a...

  1. 9 CFR 315.1 - Carcasses and parts passed for cooking; rendering into lard or tallow.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Carcasses and parts passed for cooking... PARTS PASSED FOR COOKING § 315.1 Carcasses and parts passed for cooking; rendering into lard or tallow. Carcasses and parts passed for cooking may be rendered into lard in accordance with § 319.702 of this...

  2. 22 CFR 9b.8 - Term and renewal of Department of State press building passes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... building passes. 9b.8 Section 9b.8 Foreign Relations DEPARTMENT OF STATE GENERAL REGULATIONS GOVERNING DEPARTMENT OF STATE PRESS BUILDING PASSES § 9b.8 Term and renewal of Department of State press building passes. (a) Department of State press building passes for U.S. citizens are issued with three years...

  3. Productivity and cost of conventional understory biomass harvesting systems

    Treesearch

    Douglas E. Miller; Thomas J. Straka; Bryce J. Stokes; William Watson

    1987-01-01

    Conventional harvesting equipment was tested for removing forest understory biomass (energywood) for use as fuel. Two types of systems were tested--a one-pass system and a two-pass system. In the one-pass system, the energywood and pulpwood were harvested simultaneously. In the two-pass system, the energywood was harvested in a first pass through the stand, and the...

  4. 76 FR 78144 - Amendment of Class E Airspace; Anaktuvuk Pass, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-16

    ... Anaktuvuk Pass Airport, Anaktuvuk Pass, AK. The creation of two standard instrument approach procedures at... 700 feet above the surface, at Anaktuvuk Pass Airport, to accommodate the creation of two standard...

  5. Risk appraisal of passing zones on two-lane rural highways and policy applications.

    PubMed

    Mwesige, Godfrey; Farah, Haneen; Koutsopoulos, Haris N

    2016-05-01

    Passing on two-lane rural highways is associated with risks of head-on collision resulting from unsafe completion of passing maneuvers in the opposite traffic lane. In this paper, we explore the use of time-to-collision (TTC) as a surrogate safety measure of the risk associated with passing maneuvers. Logistic regression models to predict the probability to end the passing maneuver with TTC less than 2 or 3s-threshold were developed with the time-gap from initiation of the maneuver to arrival of the opposite vehicle (effective accepted gap), and the passing duration as explanatory variables. The data used for model estimation was collected using stationary tripod-mounted camcorders at 19 passing zones in Uganda. Results showed that passing maneuvers completed with TTC less than 3s are unsafe and often involved sudden speed reduction, flashing headlights, and lateral shift to shoulders. Model sensitivity analysis was conducted for observed passing durations involving passenger cars or short trucks (2-3 axles), and long trucks (4-7 axles) as the passed vehicles for 3s TTC-threshold. Three risk levels were proposed based on the probability to complete passing maneuvers with TTC less than 3s for a range of opposite direction traffic volumes. Applications of the results for safety improvements of two-lane rural highways are also discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. 7 CFR 51.2285 - Tolerances for size.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... for size Smaller than three-fourths halves Will not pass through 24/64 inch round hole Pass through 24/64 inch round hole Pass through 16/64 inch round hole Pass through 8/64 inch round hole Halves 5 1...

  7. 7 CFR 51.2285 - Tolerances for size.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... for size Smaller than three-fourths halves Will not pass through 24/64 inch round hole Pass through 24/64 inch round hole Pass through 16/64 inch round hole Pass through 8/64 inch round hole Halves 5 1...

  8. 7 CFR 51.2285 - Tolerances for size.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... for size Smaller than three-fourths halves Will not pass through 24/64 inch round hole Pass through 24/64 inch round hole Pass through 16/64 inch round hole Pass through 8/64 inch round hole Halves 5 1...

  9. Case Study of the Denver Regional Transportation District Eco Pass Program

    DOT National Transportation Integrated Search

    1993-11-01

    This report documents the Denver Regional Transportation District (RTD) Eco Pass Program and evaluates its impacts. The Eco Pass is an annual, unlimited-use photo identification pass covering transportation on all RTD transit routes. Employers in the...

  10. School Bond Referenda Reloaded: An Examination of a School District in Passing a Subsequent Bond Referendum after Failing to Pass Previous Bond Referenda

    ERIC Educational Resources Information Center

    Benzaquen, Eitan Yacov

    2016-01-01

    In April 2008, the Wisconsin Erie School District attempted and failed to pass a school bond referendum to renovate its high school. In November 2008, again the school district did not pass a referendum. Interestingly, in the 2009-2010 school year, the district was successful in passing a bond referendum. Although the original bond measure called…

  11. Thermal effectiveness of multiple shell and tube pass TEMA E heat exchangers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pignotti, A.; Tamborenea, P.I.

    1988-02-01

    The thermal effectiveness of a TEMAE shell-and-tube heat exchanger, with one shell pass and an arbitrary number of tube passes, is determined under the usual simplifying assumptions of perfect transverse mixing of the shell fluid, no phase change, and temperature independence of the heat capacity rates and the heat transfer coefficient. A purely algebraic solution is obtained for the effectiveness as a functions of the heat capacity rate ratio and the number of heat transfer units. The case with M shell passes and N tube passes is easily expressed in terms of the single-shell-pass case.

  12. Integrating Research, Quality Improvement, and Medical Education for Better Handoffs and Safer Care: Disseminating, Adapting, and Implementing the I-PASS Program.

    PubMed

    Starmer, Amy J; Spector, Nancy D; West, Daniel C; Srivastava, Rajendu; Sectish, Theodore C; Landrigan, Christopher P

    2017-07-01

    In 2009 the I-PASS Study Group was formed by patient safety, medical education, health services research, and clinical experts from multiple institutions in the United States and Canada. When the I-PASS Handoff Program, which was developed by the I-PASS Study Group, was implemented in nine hospitals, it was associated with a 30% reduction in injuries due to medical errors and significant improvements in handoff processes, without any adverse effects on provider work flow. To effectively disseminate and adapt I-PASS for use across specialties and disciplines, a series of federally and privately funded dissemination and implementation projects were carried out following the publication of the initial study. The results of these efforts have informed ongoing initiatives intended to continue adapting and scaling the program. As of this writing, I-PASS Study Group members have directly worked with more than 50 hospitals to facilitate implementation of I-PASS. To further disseminate I-PASS, Study Group members delivered hundreds of academic presentations, including plenaries at scientific meetings, workshops, and institutional Grand Rounds. Some 3,563 individuals, representing more than 500 institutions in the 50 states in the United States, the District of Columbia, Puerto Rico, and 57 other countries, have requested access to I-PASS materials. Most recently, the I-PASS SM Patient Safety Institute has developed a virtual immersion training platform, mobile handoff observational tools, and processes to facilitate further spread of I-PASS. Implementation of I-PASS has been associated with substantial improvements in patient safety and can be applied to a variety of disciplines and types of patient handoffs. Widespread implementation of I-PASS has the potential to substantially improve patient safety in the United States and beyond. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  13. Ultra-compact resonant tunneling-based TE-pass and TM-pass polarizers for SOI platform.

    PubMed

    Azzam, Shaimaa I; Obayya, Salah S A

    2015-03-15

    We investigate the polarization-dependent resonance tunneling effect in silicon waveguides to achieve ultra-compact and highly efficient polarization fitters for integrated silicon photonics, to the best of our knowledge for the first time. We hence propose simple structures for silicon-on-insulator transverse electric (TE)-pass and transverse magnetic (TM)-pass polarizers based on the resonance tunneling effect in silicon waveguides. The suggested TE-pass polarizer has insertion losses (IL), extinction ratio (ER), and return losses (RL) of 0.004 dB, 18 dB, and 24 dB, respectively; whereas, the TM-pass polarizer is characterized by IL, ER, and RL of 0.15 dB, 20 dB, and 23 dB, respectively. Both polarizers have an ultra-short device length of only 1.35 and 1.31 μm for the TE-pass and the TM-pass polarizers which are the shortest reported lengths to the best of our knowledge.

  14. Microstructural and mechanical responses to various rolling speeds determined in multi-pass break-down rolling of AZ31B alloy

    NASA Astrophysics Data System (ADS)

    Jia, Weitao; Tang, Yan; Ning, Fangkun; Le, Qichi; Cui, Jianzhong

    2018-04-01

    Different rolling operations of as-cast AZ31B alloy were performed under different rolling speed (18 ∼ 72 m min‑1) and rolling pass conditions at 400 °C. Microstructural studies, tensile testing and formability evaluation relevant to each rolling operation were investigated. For 1-pass rolling, coarse average grain size (CAGS) region gradually approached the center layer as the rolling speed increased. Moreover, twins, shear bands and coarse-grain structures were the dominant components in the microstructure of plates rolled at 18, 48 and 72 m min‑1, respectively, indicating the severe deformation inhomogeneity under the high reduction per pass condition. For 2-pass rolling and 4-pass rolling, dynamic recrystallization was observed to be well and CAGS region has substantially disappeared, indicating the significant improvement in deformation uniformity and further the grain homogenization under the conditions. Microstructure uniformity degree of 2-pass rolled plates did not vary much as the rolling speed varied. On this basis, shear band distribution dominated the deformation behavior during the uniaxial tension of the 2-pass rolled plates. However, microstructure uniformity accompanied by twin distribution played a leading role in stretching the 4-pass rolled plates.

  15. Global HRSC Image Mosaics of Mars: Dodging for High-Pass Filtering, Combined with Low-Pass-Filtered OMEGA Mosaics

    NASA Astrophysics Data System (ADS)

    McGuire, P. C.; Walter, S. H. G.; van Gasselt, S.; Dumke, A.; Dunker, T.; Gross, C.; Michael, G.; Wendt, L.; Audouard, J.; Ody, A.; Poulet, F.

    2014-07-01

    We discuss our approach towards automatically mosaicking hundreds of the HRSC panchromatic or RGB images together. Our best results consist of adding a high-pass-filtered HRSC mosaic to a low-pass-filtered OMEGA global mosaic.

  16. Improving liquid chromatography-tandem mass spectrometry determinations by modifying noise frequency spectrum between two consecutive wavelet-based low-pass filtering procedures.

    PubMed

    Chen, Hsiao-Ping; Liao, Hui-Ju; Huang, Chih-Min; Wang, Shau-Chun; Yu, Sung-Nien

    2010-04-23

    This paper employs one chemometric technique to modify the noise spectrum of liquid chromatography-tandem mass spectrometry (LC-MS/MS) chromatogram between two consecutive wavelet-based low-pass filter procedures to improve the peak signal-to-noise (S/N) ratio enhancement. Although similar techniques of using other sets of low-pass procedures such as matched filters have been published, the procedures developed in this work are able to avoid peak broadening disadvantages inherent in matched filters. In addition, unlike Fourier transform-based low-pass filters, wavelet-based filters efficiently reject noises in the chromatograms directly in the time domain without distorting the original signals. In this work, the low-pass filtering procedures sequentially convolve the original chromatograms against each set of low pass filters to result in approximation coefficients, representing the low-frequency wavelets, of the first five resolution levels. The tedious trials of setting threshold values to properly shrink each wavelet are therefore no longer required. This noise modification technique is to multiply one wavelet-based low-pass filtered LC-MS/MS chromatogram with another artificial chromatogram added with thermal noises prior to the other wavelet-based low-pass filter. Because low-pass filter cannot eliminate frequency components below its cut-off frequency, more efficient peak S/N ratio improvement cannot be accomplished using consecutive low-pass filter procedures to process LC-MS/MS chromatograms. In contrast, when the low-pass filtered LC-MS/MS chromatogram is conditioned with the multiplication alteration prior to the other low-pass filter, much better ratio improvement is achieved. The noise frequency spectrum of low-pass filtered chromatogram, which originally contains frequency components below the filter cut-off frequency, is altered to span a broader range with multiplication operation. When the frequency range of this modified noise spectrum shifts toward the high frequency regimes, the other low-pass filter is able to provide better filtering efficiency to obtain higher peak S/N ratios. Real LC-MS/MS chromatograms, of which typically less than 6-fold peak S/N ratio improvement achieved with two consecutive wavelet-based low-pass filters remains the same S/N ratio improvement using one-step wavelet-based low-pass filter, are improved to accomplish much better ratio enhancement 25-folds to 40-folds typically when the noise frequency spectrum is modified between two low-pass filters. The linear standard curves using the filtered LC-MS/MS signals are validated. The filtered LC-MS/MS signals are also reproducible. The more accurate determinations of very low concentration samples (S/N ratio about 7-9) are obtained using the filtered signals than the determinations using the original signals. Copyright 2010 Elsevier B.V. All rights reserved.

  17. Getting Better or Getting Well? The Patient Acceptable Symptom State (PASS) Better Predicts Patient's Satisfaction than the Decrease of Pain, in Knee Osteoarthritis Subjects Treated with Viscosupplementation.

    PubMed

    Conrozier, Thierry; Monet, Matthieu; Lohse, Anne; Raman, Raghu

    2017-08-01

    Background In the management of knee osteoarthritis (OA), patient-reported-outcomes (PROs) are being developed for relevant assessment of pain. The patient acceptable symptom state (PASS) is a relevant cutoff, which allows classifying patients as being in "an acceptable state" or not. Viscosupplementation is a therapeutic modality widely used in patients with knee OA that many patients are satisfied with despite meta-analyses give conflicting results. Objectives To compare, 6 months after knee viscosupplementation, the percentage of patients who reached the PASS threshold (PASS +) with that obtained from other PROs. Methods Data of 53 consecutive patients treated with viscosupplementation (HANOX-M-XL) and followed using a standardized procedure, were analyzed at baseline and month 6. The PROs were Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and function, patient's global assessment of pain (PGAP), patient's self-assessment of satisfaction, PASS for WOMAC pain and PGAP. Results At baseline, WOMAC pain and PGAP (range 0-10) were 4.6 (1.1) and 6.0 (1.1). At month 6, they were 1.9 (1.2) and 3.1 (5) ( P < 0.0001). At 6 months, 83% of patients were "PASS + pain," 100% "PASS + function," 79% "PASS + PGAP," 79% were satisfied, and 73.6% experienced a ≥50% decrease in WOMAC pain. Among "PASS + pain" and "PASS + PGAP" subjects, 90% and 83.3% were satisfied with the treatment, respectively. Conclusion In daily practice, clinical response to viscosupplementation slightly varies according to PROs. "PASS + PGAP" was the most related to patient satisfaction.

  18. Alternative Fuels Data Center

    Science.gov Websites

    High Occupancy Vehicle (HOV) Lane Exemption Through the Clean Pass Program, eligible plug-in number of occupants in the vehicle. Vehicles must display the Clean Pass vehicle sticker, which is . For a list of eligible vehicles and Clean Pass sticker application instructions, see the Clean Pass

  19. 49 CFR 383.135 - Passing knowledge and skills tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Passing knowledge and skills tests. 383.135... COMMERCIAL DRIVER'S LICENSE STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.135 Passing knowledge and skills tests. (a) Knowledge tests. (1) To achieve a passing score on each of the knowledge tests, a...

  20. 49 CFR 383.135 - Passing knowledge and skills tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Passing knowledge and skills tests. 383.135... COMMERCIAL DRIVER'S LICENSE STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.135 Passing knowledge and skills tests. (a) Knowledge tests. (1) To achieve a passing score on each of the knowledge tests, a...

  1. 49 CFR 383.135 - Passing knowledge and skills tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Passing knowledge and skills tests. 383.135... COMMERCIAL DRIVER'S LICENSE STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.135 Passing knowledge and skills tests. (a) Knowledge tests. (1) To achieve a passing score on each of the knowledge tests, a...

  2. 49 CFR 178.337-4 - Joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... must be considered as essential variables: Number of passes; thickness of plate; heat input per pass... not be used. The number of passes, thickness of plate, and heat input per pass may not vary more than... machine heat processes, provided such surfaces are remelted in the subsequent welding process. Where there...

  3. 49 CFR 178.337-4 - Joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... must be considered as essential variables: Number of passes; thickness of plate; heat input per pass... not be used. The number of passes, thickness of plate, and heat input per pass may not vary more than... machine heat processes, provided such surfaces are remelted in the subsequent welding process. Where there...

  4. 49 CFR 178.337-4 - Joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... must be considered as essential variables: Number of passes; thickness of plate; heat input per pass... not be used. The number of passes, thickness of plate, and heat input per pass may not vary more than... machine heat processes, provided such surfaces are remelted in the subsequent welding process. Where there...

  5. 49 CFR 178.337-4 - Joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... must be considered as essential variables: Number of passes; thickness of plate; heat input per pass... not be used. The number of passes, thickness of plate, and heat input per pass may not vary more than... machine heat processes, provided such surfaces are remelted in the subsequent welding process. Where there...

  6. Spacecraft control center automation using the generic inferential executor (GENIE)

    NASA Technical Reports Server (NTRS)

    Hartley, Jonathan; Luczak, Ed; Stump, Doug

    1996-01-01

    The increasing requirement to dramatically reduce the cost of mission operations led to increased emphasis on automation technology. The expert system technology used at the Goddard Space Flight Center (MD) is currently being applied to the automation of spacecraft control center activities. The generic inferential executor (GENIE) is a tool which allows pass automation applications to be constructed. The pass script templates constructed encode the tasks necessary to mimic flight operations team interactions with the spacecraft during a pass. These templates can be configured with data specific to a particular pass. Animated graphical displays illustrate the progress during the pass. The first GENIE application automates passes of the solar, anomalous and magnetospheric particle explorer (SAMPEX) spacecraft.

  7. BEHAVIORAL COACHING TO IMPROVE OFFENSIVE LINE PASS-BLOCKING SKILLS OF HIGH SCHOOL FOOTBALL ATHLETES

    PubMed Central

    Stokes, John V; Luiselli, James K; Reed, Derek D; Fleming, Richard K

    2010-01-01

    We evaluated several behavioral coaching procedures for improving offensive line pass-blocking skills with 5 high school varsity football players. Pass blocking was measured during practice drills and games, and our intervention included descriptive feedback with and without video feedback and teaching with acoustical guidance (TAG). Intervention components and pass blocking were evaluated in a multiple baseline design, which showed that video feedback and TAG were the most effective procedures. For all players, improved pass blocking matched a standard derived by observing more experienced linemen and was evident in games. Additional intervention was required to maintain pass-blocking proficiency. Issues pertinent to behavioral coaching and sport psychology research are discussed. PMID:21358905

  8. Three-dimensional flow characteristics of aluminum alloy in multi-pass equal channel angular pressing

    NASA Astrophysics Data System (ADS)

    Jin, Young-Gwan; Son, Il-Heon; Im, Yong-Taek

    2010-06-01

    Experiments with a square specimen made of commercially pure aluminum alloy (AA1050) were conducted to investigate deformation behaviour during a multi-pass Equal Channel Angular Pressing (ECAP) for routes A, Bc, and C up to four passes. Three-dimensional finite element numerical simulations of the multi-pass ECAP were carried out in order to evaluate the influence of processing routes and number of passes on local flow behaviour by applying a simplified saturation model of flow stress under an isothermal condition. Simulation results were investigated by comparing them with the experimentally measured data in terms of load variations and microhardness distributions. Also, transmission electron microscopy analysis was employed to investigate the microstructural changes. The present work clearly shows that the three-dimensional flow characteristics of the deformed specimen were dependent on the strain path changes due to the processing routes and number of passes that occurred during the multi-pass ECAP.

  9. Modeling a maintenance simulation of the geosynchronous platform

    NASA Technical Reports Server (NTRS)

    Kleiner, A. F., Jr.

    1980-01-01

    A modeling technique used to conduct a simulation study comparing various maintenance routines for a space platform is dicussed. A system model is described and illustrated, the basic concepts of a simulation pass are detailed, and sections on failures and maintenance are included. The operation of the system across time is best modeled by a discrete event approach with two basic events - failure and maintenance of the system. Each overall simulation run consists of introducing a particular model of the physical system, together with a maintenance policy, demand function, and mission lifetime. The system is then run through many passes, each pass corresponding to one mission and the model is re-initialized before each pass. Statistics are compiled at the end of each pass and after the last pass a report is printed. Items of interest typically include the time to first maintenance, total number of maintenance trips for each pass, average capability of the system, etc.

  10. 78 FR 5477 - Agency Information Collection Activities: InfoPass System, No Form Number; Extension, Without...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-25

    ...-0113] Agency Information Collection Activities: InfoPass System, No Form Number; Extension, Without... Change, of a Currently Approved Collection. (2) Title of the Form/Collection: InfoPass System. (3) Agency...: Primary: Individuals or households. The InfoPass system allows an applicant or petitioner to schedule an...

  11. 77 FR 65898 - Agency Information Collection Activities: InfoPass System, No Form Number; Extension, Without...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-31

    ...-0113] Agency Information Collection Activities: InfoPass System, No Form Number; Extension, Without...) Title of the Form/Collection: InfoPass System. (3) Agency form number, if any, and the applicable... InfoPass system allows an applicant or petitioner to schedule an interview appointment with USCIS...

  12. 78 FR 35625 - Sabine Pass Liquefaction Expansion, LLC; Sabine Pass Liquefaction, LLC; Sabine Pass LNG, L.P...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-13

    ... Pipeline, L.P.: Notice of Intent To Prepare an Environmental Assessment for the Planned Sabine Pass Liquefaction Expansion Project and Cheniere Creole Trail Pipeline Expansion Project, Request for Comments on... Expansion Project (SPLE Project) and the Cheniere Creole Trail Pipeline, L.P. (CCTPL) Chenier Creole Trail...

  13. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  14. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  15. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  16. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  17. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  18. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  19. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  20. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  1. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  2. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  3. 36 CFR 13.918 - Sable Pass Wildlife Viewing Area.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Sable Pass Wildlife Viewing... Preserve General Provisions § 13.918 Sable Pass Wildlife Viewing Area. (a) Entry into the Sable Pass Wildlife Viewing Area is prohibited from May 1 to September 30 unless authorized by the Superintendent. (b...

  4. 36 CFR 13.918 - Sable Pass Wildlife Viewing Area.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Sable Pass Wildlife Viewing... Preserve General Provisions § 13.918 Sable Pass Wildlife Viewing Area. (a) Entry into the Sable Pass Wildlife Viewing Area is prohibited from May 1 to September 30 unless authorized by the Superintendent. (b...

  5. 36 CFR 13.918 - Sable Pass Wildlife Viewing Area.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Sable Pass Wildlife Viewing... Preserve General Provisions § 13.918 Sable Pass Wildlife Viewing Area. (a) Entry into the Sable Pass Wildlife Viewing Area is prohibited from May 1 to September 30 unless authorized by the Superintendent. (b...

  6. 36 CFR 13.918 - Sable Pass Wildlife Viewing Area.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 1 2014-07-01 2014-07-01 false Sable Pass Wildlife Viewing... Preserve General Provisions § 13.918 Sable Pass Wildlife Viewing Area. (a) Entry into the Sable Pass Wildlife Viewing Area is prohibited from May 1 to September 30 unless authorized by the Superintendent. (b...

  7. 36 CFR 13.918 - Sable Pass Wildlife Viewing Area.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 1 2013-07-01 2013-07-01 false Sable Pass Wildlife Viewing... Preserve General Provisions § 13.918 Sable Pass Wildlife Viewing Area. (a) Entry into the Sable Pass Wildlife Viewing Area is prohibited from May 1 to September 30 unless authorized by the Superintendent. (b...

  8. 9 CFR 310.6 - Carcasses and parts passed for cooking; marking.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Carcasses and parts passed for cooking... INSPECTION AND CERTIFICATION POST-MORTEM INSPECTION § 310.6 Carcasses and parts passed for cooking; marking. Carcasses and parts passed for cooking shall be marked conspicuously on the surface tissues thereof by a...

  9. PASS Student Leader and Mentor Roles: A Tertiary Leadership Pathway

    ERIC Educational Resources Information Center

    Skalicky, Jane; Caney, Annaliese

    2010-01-01

    In relation to developing leadership skills during tertiary studies, this paper considers the leadership pathway afforded by a Peer Assisted Study Sessions (PASS) program which includes the traditional PASS Leader role and a more senior PASS Mentor role. Data was collected using a structured survey with open-ended questions designed to capture the…

  10. Disruption rates for one vulnerable soil in Organ Pipe Cactus National Monument, Arizona, USA

    USGS Publications Warehouse

    Webb, Robert H.; Esque, Todd C.; Nussear, Kenneth E.; Sturm, Mark

    2013-01-01

    Rates of soil disruption from hikers and vehicle traffic are poorly known, particularly for arid landscapes. We conducted an experiment in Organ Pipe Cactus National Monument (ORPI) in western Arizona, USA, on an air-dry very fine sandy loam that is considered to be vulnerable to disruption. We created variable-pass tracks using hikers, an all-terrain vehicle (ATV), and a four-wheel drive vehicle (4WD) and measured changes in cross-track topography, penetration depth, and bulk density. Hikers (one pass = 5 hikers) increased bulk density and altered penetration depth but caused minimal surface disruption up to 100 passes; a minimum of 10 passes were required to overcome surface strength of this dry soil. Both ATV and 4WD traffic significantly disrupted the soil with one pass, creating deep ruts with increasing passes that rendered the 4WD trail impassable after 20 passes. Despite considerable soil loosening (dilation), bulk density increased in the vehicle trails, and lateral displacement created berms of loosened soil. This soil type, when dry, can sustain up to 10 passes of hikers but only one vehicle pass before significant soil disruption occurs; greater disruption is expected when soils are wet. Bulk density increased logarithmically with applied pressure from hikers, ATV, and 4WD.

  11. Effect of reduction of area on microstructure and mechanical properties of twinning-induced plasticity steel during wire drawing

    NASA Astrophysics Data System (ADS)

    Hwang, Joong-Ki; Son, Il-Heon; Yoo, Jang-Yong; Zargaran, A.; Kim, Nack J.

    2015-09-01

    The effect of reduction of area (RA), 10%, 20%, and 30%, during wire drawing on the inhomogeneities in microstructure and mechanical properties along the radial direction of Fe-Mn-Al-C twinning-induced plasticity steel has been investigated. After wire drawing, the deformation texture developed into the major <111> and minor <100> duplex fiber texture. However, the <111> texture became more pronounced in both center and surface areas as the RA per pass increased. It also shows that a larger RA per pass resulted in a higher yield strength and smaller elongation than a smaller RA per pass at all strain levels. Although inhomogeneities in microstructure and mechanical properties along the radial direction decreased with increasing RA per pass, there existed an optimum RA per pass for maximum drawing limit. Insufficient penetration of strain from surface to center at small RA per pass (e.g., 10%) and high friction and unsound metal flow at large RA per pass (e.g., 30%) all resulted in heterogeneous microstructure and mechanical properties along the radial direction of drawn wire. On the other hand, 20% RA per pass improved the drawing limit by about 30% as compared to the 10% and 30% RAs per pass.

  12. A Comparison of Four- Versus Three-Pass Transjugular Biopsy Using a 19-G Tru-Cut Needle and a Randomized Study Using a Cassette to Prevent Biopsy Fragmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vibhakorn, Shusang; Cholongitas, Evangelos; Kalambokis, George

    2009-05-15

    Recently, it has been shown that transjugular liver biopsy (TJLB) with three passes gives comparable specimens to percutaneous liver biopsy (PLB). The aim of this study was to evaluate the adequacy of TJLB using four passes in a consecutive series of patients, and whether using a supportive cassette can prevent fragmentation. One hundred consecutive TJLBs in 92 patients (48 transplanted), always using four passes (19-G Tru-Cut), were compared to three-pass TJLBs. The four-pass TJLB specimens were randomized at a 1:1 ratio of liver cores placed in a cassette versus not. The four-pass TJLBs, compared to three-pass TJLBs, resulted in bettermore » specimens for length ({>=}25 mm: 50% vs. 35%; p = 0.026) and number of complete portal tracts (CPTs) ({>=}11: 40% vs. 26%; p = 0.027), without a higher complication rate. The four-pass TJLB with {>=}11 CPTs had a median length of 27 mm, and 57% of them longer than 28 mm contained {>=}11 CPTs. Putting the liver biopsy cores into a cassette did not improve the fragmentation rate or adequacy of the specimen (length and number of CPTs) of TJLB. We conclude that at least four passes with TJLB should be performed when liver specimens are needed for grading and staging. Using a supportive cassette did not reduce fragmentation.« less

  13. Flow structure, heat transfer and pressure drop in varying aspect ratio two-pass rectangular smooth channels

    NASA Astrophysics Data System (ADS)

    Siddique, Waseem; El-Gabry, Lamyaa; Shevchuk, Igor V.; Hushmandi, Narmin B.; Fransson, Torsten H.

    2012-05-01

    Two-pass channels are used for internal cooling in a number of engineering systems e.g., gas turbines. Fluid travelling through the curved path, experiences pressure and centrifugal forces, that result in pressure driven secondary motion. This motion helps in moving the cold high momentum fluid from the channel core to the side walls and plays a significant role in the heat transfer in the channel bend and outlet pass. The present study investigates using Computational Fluid Dynamics (CFD), the flow structure, heat transfer enhancement and pressure drop in a smooth channel with varying aspect ratio channel at different divider-to-tip wall distances. Numerical simulations are performed in two-pass smooth channel with aspect ratio Win/H = 1:3 at inlet pass and Wout/H = 1:1 at outlet pass for a variety of divider-to-tip wall distances. The results show that with a decrease in aspect ratio of inlet pass of the channel, pressure loss decreases. The divider-to-tip wall distance (Wel) not only influences the pressure drop, but also the heat transfer enhancement at the bend and outlet pass. With an increase in the divider-to-tip wall distance, the areas of enhanced heat transfer shifts from side walls of outlet pass towards the inlet pass. To compromise between heat transfer and pressure drop in the channel, Wel/H = 0.88 is found to be optimum for the channel under study.

  14. Rethinking covert stuttering.

    PubMed

    Constantino, Christopher Dominick; Manning, Walter H; Nordstrom, Susan Naomi

    2017-09-01

    The experience of passing as fluent, also called covert stuttering, has been uncritically framed as an inherently negative pursuit. Historically passing has been understood as a repression of one's true, authentic self in response to either psychological distress or social discrimination. The authors of this paper seek a more nuanced understanding of passing. We ask, how must a person relate to herself in order to pass as fluent? This is a qualitative research study in which the authors utilized the ethical theories of philosopher Michel Foucault to contextualize data obtained from semi-structured interviews with nine participants who pass as fluent. Rather than a repression of an authentic self our data suggests passing is more usefully understood as a form of resistance by people who stutter to a hostile society. Participants learned from experiences of delegitimization that their stuttering had ethical ramifications. Consequently, they used a variety of self-forming practices to pass and thereby achieve the privileges that come with perceived able-bodiedness. Passing as fluent is not an inauthentic form of stuttering but a form of stuttering that is produced through the use of specific technologies of communication. These technologies of communication are constituted by the unique ethical relationship of the person who stutters with herself. Passing can be understood as an active form of resistance rather than a passive form of repression. By theorizing passing as fluent as an ethical relationship, we open up the possibility of changing the relationship and performing it differently. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A swath across the great divide: Kelp forests across the Samalga Pass biogeographic break

    USGS Publications Warehouse

    Konar, Brenda H.; Edwards, Matthew S.; Bland, Aaron; Metzger, Jacob; Ravelo, Alexandra; Traiger, Sarah; Weitzman, Ben P.

    2017-01-01

    Biogeographic breaks are often described as locations where a large number of species reach their geographic range limits. Samalga Pass, in the eastern Aleutian Archipelago, is a known biogeographic break for the spatial distribution of several species of offshore-pelagic communities, including numerous species of cold-water corals, zooplankton, fish, marine mammals, and seabirds. However, it remains unclear whether Samalga Pass also serves as a biogeographic break for nearshore benthic communities. The occurrence of biogeographic breaks across multiple habitats has not often been described. In this study, we examined if the biogeographic break for offshore-pelagic communities applies to nearshore kelp forests. To examine whether Samalga Pass serves as a biogeographic break for kelp forest communities, this study compared abundance, biomass and percent bottom cover of species associated with kelp forests on either side of the pass. We observed marked differences in kelp forest community structure, with some species reaching their geographic range limits on the opposing sides of the pass. In particular, the habitat-forming kelp Nereocystis luetkeana, and the predatory sea stars Pycnopodia helianthoides and Orthasterias koehleri all occurred on the eastern side of Samalga Pass but were not observed west of the pass. In contrast, the sea star Leptasterias camtschatica dispar was observed only on the western side of the pass. We also observed differences in overall abundance and biomass of numerous associated fish, invertebrate and macroalgal species on opposing sides of the pass. We conclude that Samalga Pass is important biogeographic break for kelp forest communities in the Aleutian Archipelago and may demark the geographic range limits of several ecologically important species.

  16. Non-exercise Estimation of V02max Using a Dichotomy of Meeting or Not Meeting DHHS Physical Activity Recommendations

    NASA Technical Reports Server (NTRS)

    Wier, Larry T.; Jackson, Allen W.; Jackson, Andrew S.

    2009-01-01

    The physical activity guidelines (PAG) established by the US Dept. of Health and Human Services in 2008 is consistent with a rating of >/= 6 on the 11-point NASA Physical Activity Status Scale (PASS). Wier, et. al. developed non-exercise models for estimating VO2(sub max) from a combination of PASS, age, gender and either waist girth (WG) (R = 0.810, SEE= 4.799 ml/kg/min), %Fat (R = 0. 817, SEE = 4.716 ml/kg/min) or BMI (R = 0.802, SEE = 4.900 ml . kg-1. min -1 ). PURPOSE: to develop non-exercise models to estimate VO2max from age, gender, body composition (WG, %Fat, BMI) and PASS dichotomized at meets or does not meet the PAG (PAG-PASS), and to compare the accuracy of the PAG-PASS models with the models using the 11-point PASS. METHODS: 2417 men and 384 women were measured for VO2max by indirect calorimetry (RER >1.1); age (yr), gender by M = 1, W = 0; WG at the umbilicus; %fat by skin-folds, BMI by weight (kg) divided by height squared (m 2 ) , and PAGPASS by PASS < 6 = 0 and =/> 6 = 1. RESULTS: Three models were developed by multiple regression to estimate VO2(sub max) from age, gender, PAG-PASS and either WG (R = 0.790, SEE=5.019 ml/kg/min), %FAT (R= 0.080, SEE = 4.915 ml/kg/min) or BMI (R = 0.777, SEE = 5.162ml/kg/min). Cross-validation by the PRESS technique confirmed these statistics. Simple correlations between measured VO2(sub max) and estimates from the PAG-PASS models with WG, %Fat and BMI were 0.790, 0.800 and 0.777, minimally different from the correlations obtained with the PASS models (0.810, 0.810, and 0.802). PAG-PASS and PASS model constant errors were also similar: < 1 ml/kg/min for subsamples of age, gender, PASS and for VO2(sub max) between 30 and 50 ml/kg/min (70% of the sample) but > 1 ml/kg/min for VO2(sub max) <30 and >50 ml/kg/min. CONCLUSIONS: Non-exercise models using the combined effects of age, gender, body composition and the dichotomized PAG-PASS provide estimates of VO2(sub max) that are accurate for most adults, and the accuracy of these models are similar to previously published models using the 11-point PASS.

  17. 75 FR 32810 - 60-Day Notice of Intention To Request Clearance of Collection of Information; Opportunity for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-09

    ... Recreational Lands Pass available, for free, to any United States citizen or person domiciled in the United... Parks and Federal Recreational Lands Access Pass (Interagency Access Pass) was created to meet the... published them within the America the Beautiful--The National Parks and Federal Recreational Lands Pass...

  18. 9 CFR 312.3 - Official marks and devices to identify inspected and passed equine products.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... inspected and passed equine products. 312.3 Section 312.3 Animals and Animal Products FOOD SAFETY AND... § 312.3 Official marks and devices to identify inspected and passed equine products. (a) The official... § 317.2 of this subchapter to identify inspected and passed mule and other (nonhorse) equine carcasses...

  19. 22 CFR 9b.5 - Temporary Department of State press building passes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Temporary Department of State press building passes. 9b.5 Section 9b.5 Foreign Relations DEPARTMENT OF STATE GENERAL REGULATIONS GOVERNING DEPARTMENT OF STATE PRESS BUILDING PASSES § 9b.5 Temporary Department of State press building passes. A media...

  20. Hydrogen production by high-temperature water splitting using electron-conducting membranes

    DOEpatents

    Lee, Tae H.; Wang, Shuangyan; Dorris, Stephen E.; Balachandran, Uthamalingam

    2004-04-27

    A device and method for separating water into hydrogen and oxygen is disclosed. A first substantially gas impervious solid electron-conducting membrane for selectively passing hydrogen is provided and spaced from a second substantially gas impervious solid electron-conducting membrane for selectively passing oxygen. When steam is passed between the two membranes at disassociation temperatures the hydrogen from the disassociation of steam selectively and continuously passes through the first membrane and oxygen selectively and continuously passes through the second membrane, thereby continuously driving the disassociation of steam producing hydrogen and oxygen.

  1. Multiple pass gas absorption cell utilizing a spherical mirror opposite one or more pair of obliquely disposed flat mirrors

    NASA Technical Reports Server (NTRS)

    Pearson, Richard (Inventor); Lynch, Dana H. (Inventor); Gunter, William D. (Inventor)

    1995-01-01

    A method and apparatus for passing light bundles through a multiple pass sampling cell is disclosed. The multiple pass sampling cell includes a sampling chamber having first and second ends positioned along a longitudinal axis of the sampling cell. The sampling cell further includes an entrance opening, located adjacent the first end of the sampling cell at a first azimuthal angular position. The entrance opening permits a light bundle to pass into the sampling cell. The sampling cell also includes an exit opening at a second azimuthal angular position. The light exit permits a light bundle to pass out of the sampling cell after the light bundle has followed a predetermined path.

  2. Lessons learned on the design and the conduct of Post-Authorization Safety Studies: review of 3 years of PRAC oversight.

    PubMed

    Engel, Pierre; Almas, Mariana Ferreira; De Bruin, Marieke Louise; Starzyk, Kathryn; Blackburn, Stella; Dreyer, Nancy Ann

    2017-04-01

    To describe and characterize the first cohort of Post-Authorization Safety Study (PASS) protocols reviewed under the recent European pharmacovigilance legislation. A systematic approach was used to compile all publicly available information on PASS protocols and assessments submitted from July 2012 to July 2015 from Pharmacovigilance Risk Assessment Committee (PRAC) minutes, European Medicines Agency (EMA) and European Network of Pharmacovigilance and Pharmacoepidemiology (ENCePP) webpages. During the study period, 189 different PASS protocols were submitted to the PRAC, half of which were entered in the ENCePP electronic register of post-authorization studies (EU-PAS) by July 2015. Those protocols were assessed during 353 PRAC reviews. The EMA published only 31% of the PRAC feedback, of which the main concerns were study design (37%) and feasibility (30%). Among the 189 PASS, slightly more involved primary data capture (58%). PASS assessing drug utilization mainly leveraged secondary data sources (58%). The majority of the PASS did not include a comparator (65%) and 35% of PASS also evaluated clinical effectiveness endpoints. To the best of our knowledge this is the first comprehensive review of three years of PASS protocols submitted under the new pharmacovigilance legislation. Our results show that both EMA and PASS sponsors could respectively increase the availability of protocol assessments and documents in the EU-PAS. Protocol content review and the high number of PRAC comments related to methodological issues and feasibility concerns should raise awareness among PASS stakeholders to design more thoughtful studies according to pharmacoepidemiological principles and existing guidelines. © 2016 The British Pharmacological Society.

  3. Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.

    PubMed

    Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P

    2018-03-01

    The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.

  4. 40 CFR 205.160-6 - Passing or failing under SEA.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Passing or failing under SEA. 205.160-6... SEA. (a) A failing vehicle is one whose measured noise level is in excess of the applicable noise... less than or equal to the number in Column A, the sample passes. (c) Pass or failure of an SEA takes...

  5. 40 CFR 205.160-6 - Passing or failing under SEA.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Passing or failing under SEA. 205.160... failing under SEA. (a) A failing vehicle is one whose measured noise level is in excess of the applicable... vehicles is less than or equal to the number in Column A, the sample passes. (c) Pass or failure of an SEA...

  6. 40 CFR 205.160-6 - Passing or failing under SEA.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Passing or failing under SEA. 205.160... failing under SEA. (a) A failing vehicle is one whose measured noise level is in excess of the applicable... vehicles is less than or equal to the number in Column A, the sample passes. (c) Pass or failure of an SEA...

  7. 40 CFR 205.160-6 - Passing or failing under SEA.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Passing or failing under SEA. 205.160... failing under SEA. (a) A failing vehicle is one whose measured noise level is in excess of the applicable... vehicles is less than or equal to the number in Column A, the sample passes. (c) Pass or failure of an SEA...

  8. 40 CFR 205.171-8 - Passing or failing under SEA.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Passing or failing under SEA. 205.171-8... failing under SEA. (a) A failing exhaust system is one which, when installed on any motorcycle which is in... in Column A, the sample passes. (c) Pass or failure of a SEA takes place when a decision that an...

  9. 40 CFR 205.160-6 - Passing or failing under SEA.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Passing or failing under SEA. 205.160... failing under SEA. (a) A failing vehicle is one whose measured noise level is in excess of the applicable... vehicles is less than or equal to the number in Column A, the sample passes. (c) Pass or failure of an SEA...

  10. The Effects on Soccer Passing Skills When Warming Up with Two Different Sized Soccer Balls

    ERIC Educational Resources Information Center

    Burcak, Keskin

    2015-01-01

    The purpose of the present research is studying the effects of warm-up with two different sizes of balls on passing skills. Loughborough Soccer Passing Test (LSPT) was conducted on 28 non-elite football players, who participated in the present research for 10 training days. LSPT is a passing skill protocol established on completing 16 passes…

  11. 9 CFR 315.3 - Disposal of products passed for cooking if not handled according to this part.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... cooking if not handled according to this part. 315.3 Section 315.3 Animals and Animal Products FOOD SAFETY... OF CARCASSES AND PARTS PASSED FOR COOKING § 315.3 Disposal of products passed for cooking if not handled according to this part. Products passed for cooking if not handled and processed in accordance...

  12. 9 CFR 315.2 - Carcasses and parts passed for cooking; utilization for food purposes after cooking.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Carcasses and parts passed for cooking; utilization for food purposes after cooking. 315.2 Section 315.2 Animals and Animal Products FOOD SAFETY AND... PARTS PASSED FOR COOKING § 315.2 Carcasses and parts passed for cooking; utilization for food purposes...

  13. 22 CFR 9b.4 - Department of State building press pass for technical crews.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Department of State building press pass for technical crews. 9b.4 Section 9b.4 Foreign Relations DEPARTMENT OF STATE GENERAL REGULATIONS GOVERNING DEPARTMENT OF STATE PRESS BUILDING PASSES § 9b.4 Department of State building press pass for technical crews...

  14. 22 CFR 9b.6 - Grounds for denial, revocation, or non-renewal of Department of State press building passes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... of Department of State press building passes. 9b.6 Section 9b.6 Foreign Relations DEPARTMENT OF STATE GENERAL REGULATIONS GOVERNING DEPARTMENT OF STATE PRESS BUILDING PASSES § 9b.6 Grounds for denial, revocation, or non-renewal of Department of State press building passes. In consultation with the Bureau of...

  15. Static Noise Margin Enhancement by Flex-Pass-Gate SRAM

    NASA Astrophysics Data System (ADS)

    O'Uchi, Shin-Ichi; Masahara, Meishoku; Sakamoto, Kunihiro; Endo, Kazuhiko; Liu, Yungxun; Matsukawa, Takashi; Sekigawa, Toshihiro; Koike, Hanpei; Suzuki, Eiichi

    A Flex-Pass-Gate SRAM, i.e. a fin-type-field-effect-transistor- (FinFET-) based SRAM, is proposed to enhance noise margin during both read and write operations. In its cell, the flip-flop is composed of usual three-terminal- (3T-) FinFETs while pass gates are composed of four-terminal- (4T-) FinFETs. The 4T-FinFETs enable to adopt a dynamic threshold-voltage control in the pass gates. During a write operation, the threshold voltage of the pass gates is lowered to enhance the writing speed and stability. During the read operation, on the other hand, the threshold voltage is raised to enhance the static noise margin. An asymmetric-oxide 4T-FinFET is helpful to manage the leakage current through the pass gate. In this paper, a design strategy of the pass gate with an asymmetric gate oxide is considered, and a TCAD-based Monte Carlo simulation reveals that the Flex-Pass-Gate SRAM based on that design strategy is expected to be effective in half-pitch 32-nm technology for low-standby-power (LSTP) applications, even taking into account the variability in the device performance.

  16. Low-cycle fatigue of Fe-20%Cr alloy processed by equal- channel angular pressing

    NASA Astrophysics Data System (ADS)

    Kaneko, Yoshihisa; Tomita, Ryuji; Vinogradov, Alexei

    2014-08-01

    Low-cycle fatigue properties were investigated on Fe-20%Cr ferritic stainless steel processed by equal channel angular pressing (ECAP). The Fe-20%Cr alloy bullets were processed for one to four passes via Route-Bc. The ECAPed samples were cyclically deformed at the constant plastic strain amplitude ɛpl of 5x10-4 at room temperature in air. After the 1-pass ECAP, low-angle grain boundaries were dominantly formed. During the low-cycle fatigue test, the 1-pass sample revealed the rapid softening which continued until fatigue fracture. Fatigue life of the 1-pass sample was shorter than that of a coarse-grained sample. After the 4-pass ECAP, the average grain size reduced down to about 1.5 μm. At initial stage of the low-cycle fatigue tests, the stress amplitude increased with increasing ECAP passes. At the samples processed for more than 2 passes, the cyclic softening was relatively moderate. It was found that fatigue life of the ECAPed Fe-20%Cr alloy excepting the 1-pass sample was improved as compared to the coarse-grained sample, even under the strain controlled fatigue condition.

  17. The comparative effectiveness of fine-needle aspiration cytology sampling policies: a simulation study.

    PubMed

    Schmidt, Robert L; Howard, Kirsten; Hall, Brian J; Layfield, Lester J

    2012-12-01

    Sample adequacy is an important aspect of overall fine-needle aspiration cytology (FNAC) performance. FNAC effectiveness is augmented by an increasing number of needle passes, but increased needle passes are associated with higher costs and greater risk of adverse events. The objective of this study was to compare the impact of several different sampling policies on FNAC effectiveness and adverse event rates using discrete event simulation. We compared 8 different sampling policies in 12 different sampling environments. All sampling policies were effective when the per-pass accuracy is high (>80%). Rapid on-site evaluation (ROSE) improves FNAC effectiveness when the per-pass adequacy rate is low. ROSE is unlikely to be cost-effective in sampling environments in which the per-pass adequacy is high. Alternative ROSE assessors (eg, cytotechnologists) may be a cost-effective alternative to pathologists when the per-pass adequacy rate is moderate (60%-80%) or when the number of needle passes is limited.

  18. Visualization of mcr mRNA in a methanogen by fluorescence in situ hybridization with an oligonucleotide probe and two-pass tyramide signal amplification (two-pass TSA-FISH).

    PubMed

    Kubota, Kengo; Ohashi, Akiyoshi; Imachi, Hiroyuki; Harada, Hideki

    2006-09-01

    Two-pass tyramide signal amplification-fluorescence in situ hybridization (two-pass TSA-FISH) with a horseradish peroxidase (HRP)-labeled oligonucleotide probe was applied to detect prokaryotic mRNA. In this study, mRNA of a key enzyme for methanogenesis, methyl coenzyme M reductase (mcr), in Methanococcus vannielii was targeted. Applicability of mRNA-targeted probes to in situ hybridization was verified by Clone-FISH. It was observed that sensitivity of two-pass TSA-FISH was significantly higher than that of TSA-FISH, which was further increased by the addition of dextran sulphate in TSA working solution. Signals from two-pass TSA-FISH were more reliable compared to the weak, spotty signals yielded by TSA-FISH.

  19. Characterization of Microstructure and Texture of 13Cr4Ni Martensitic Stainless Steel Weld Before and After Tempering =

    NASA Astrophysics Data System (ADS)

    Mokhtabad Amrei, Mohsen

    13Cr4Ni martensitic stainless steels are known for their outstanding performances in the hydroelectric industry, where they are mainly used in the construction of turbine components. Considering the size and geometry of turbine runners and blades, multi-pass welding procedures are commonly used in the fabrication and repair of such turbines. The final microstructure and mechanical properties of the weld are sensitive to the welding process parameters and thermal history. In the case of 13Cr4Ni steel, the thermal cycles imposed by the multi-pass welding operation have significant effects on the complex weld microstructure. Additionally, post-weld heat treatments are commonly used to reduce weld heterogeneity and improve the material's mechanical properties by tempering the microstructure and by forming a "room-temperature-stable austenite." In the first phase of this research, the microstructures and crystallographic textures of aswelded single-pass and double-pass welds were studied as a basis to studying the more complex multi-pass weld microstructure. This study found that the maximum hardness is obtained in high temperature heat affected zone inside the base metal. In particular, the results showed that the heat cycle exposed by the second pass increases the hardness of the previous pass because it produces a finer martensite microstructure. In areas of heat affected zone, a tempering effect is reported from 3 up to 6 millimeters far from the fusion line. Finding austenite phase in these areas are matter of interest and it can be indicative of the microstructure complexity of multi-pass welds. In the second phase of research, the microstructure of multi-pass welds was found to be more heterogeneous than that of single- and double-pass welds. Any individual pass in a multi-pass weld consists of several regions formed by adjacent weld passes heat cycle. Results showed that former austenite grains modification occurred in areas close to the subsequent weld passes. Furthermore, low angle interface laths were observed inside martensite sub-blocks over different regions. The hardness profile of a multi-pass weld was explained by the overlaying heat effects of surrounding passes. In some regions, a tempered matrix was observed, while in other regions a double-quenched microstructure was found. The final aspect of this study focused on the effects of post-weld heat treatments on reformed austenite and carbide formations, and evolution of hardness. The effects of tempering duration and temperature on microstructure were investigated. The study found that nanometer-sized carbides form at martensite lath interfaces and sub-block boundaries. Additionally, it was determined that for any holding duration, the maximum austenite percentage is achievable by tempering at 610 °C. Similarly, the maximum softening was reported for tempering at 610 °C, for any given holding period.

  20. 9 CFR 325.7 - Shipment of products requiring special supervision between official establishments under official...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... restricted product shall be marked “U.S. passed for cooking” or “pork product __ °F. __days refrigeration” or “beef passed for refrigeration,” as the case may be. In addition, a “U.S. retained” tag shall be securely affixed to each container of product passed for cooking and of beef passed for refrigeration. The...

  1. 9 CFR 325.7 - Shipment of products requiring special supervision between official establishments under official...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... restricted product shall be marked “U.S. passed for cooking” or “pork product __ °F. __days refrigeration” or “beef passed for refrigeration,” as the case may be. In addition, a “U.S. retained” tag shall be securely affixed to each container of product passed for cooking and of beef passed for refrigeration. The...

  2. 9 CFR 325.7 - Shipment of products requiring special supervision between official establishments under official...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... restricted product shall be marked “U.S. passed for cooking” or “pork product __ °F. __days refrigeration” or “beef passed for refrigeration,” as the case may be. In addition, a “U.S. retained” tag shall be securely affixed to each container of product passed for cooking and of beef passed for refrigeration. The...

  3. 9 CFR 325.7 - Shipment of products requiring special supervision between official establishments under official...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... restricted product shall be marked “U.S. passed for cooking” or “pork product __ °F. __days refrigeration” or “beef passed for refrigeration,” as the case may be. In addition, a “U.S. retained” tag shall be securely affixed to each container of product passed for cooking and of beef passed for refrigeration. The...

  4. 9 CFR 325.7 - Shipment of products requiring special supervision between official establishments under official...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... restricted product shall be marked “U.S. passed for cooking” or “pork product __ °F. __days refrigeration” or “beef passed for refrigeration,” as the case may be. In addition, a “U.S. retained” tag shall be securely affixed to each container of product passed for cooking and of beef passed for refrigeration. The...

  5. 30 CFR 57.22220 - Air passing unsealed areas (I-A, II-A, III, and V-A mines).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air passing unsealed areas (I-A, II-A, III, and V-A mines). 57.22220 Section 57.22220 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... passing unsealed areas (I-A, II-A, III, and V-A mines). Air that has passed by or through unsealed...

  6. 30 CFR 57.22220 - Air passing unsealed areas (I-A, II-A, III, and V-A mines).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air passing unsealed areas (I-A, II-A, III, and V-A mines). 57.22220 Section 57.22220 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... passing unsealed areas (I-A, II-A, III, and V-A mines). Air that has passed by or through unsealed...

  7. Playing the Game: The Impact of No Pass/No Play Sanctions on High School Athletes, A Youth Development Approach

    ERIC Educational Resources Information Center

    Oliphant, Jennifer A.

    2011-01-01

    In the original "No Pass/No Play" legislation (enacted by Texas State Legislature in 1985), students had to pass all classes with at least a 70% average to participate in sports or extracurricular activities. Since then, no pass/no play regulations have been enacted across the nation with little evidence regarding their effectiveness. Questions…

  8. Feasibility of a Modified E-PASS and POSSUM System for Postoperative Risk Assessment in Patients with Spinal Disease.

    PubMed

    Chun, Dong Hyun; Kim, Do Young; Choi, Sun Kyu; Shin, Dong Ah; Ha, Yoon; Kim, Keung Nyun; Yoon, Do Heum; Yi, Seong

    2018-04-01

    This retrospective case control study aimed to evaluate the feasibility of using Estimation of Physiological Ability and Surgical Stress (E-PASS) and Physiological and Operative Severity Score for the enumeration of Mortality and Morbidity (POSSUM) systems in patients undergoing spinal surgical procedures. Degenerative spine disease has increased in incidence in aging societies, as has the number of older adult patients undergoing spinal surgery. Many older adults are at a high surgical risk because of comorbidity and poor general health. We retrospectively reviewed 217 patients who had undergone spinal surgery at a single tertiary care. We investigated complications within 1 month after surgery. Criteria for both skin incision in E-PASS and operation magnitude in the POSSUM system were modified to fit spine surgery. We calculated the E-PASS and POSSUM scores for enrolled patients, and investigated the relationship between postoperative complications and both surgical risk scoring systems. To reinforce the predictive ability of the E-PASS system, we adjusted equations and developed modified E-PASS systems. The overall complication rate for spinal surgery was 22.6%. Forty-nine patients experienced 58 postoperative complications. Nineteen major complications, including hematoma, deep infection, pleural effusion, progression of weakness, pulmonary edema, esophageal injury, myocardial infarction, pneumonia, reoperation, renal failure, sepsis, and death, occurred in 17 patients. The area under the receiver operating characteristic curve (AUC) for predicted postoperative complications after spine surgery was 0.588 for E-PASS and 0.721 for POSSUM. For predicted major postoperative complications, the AUC increased to 0.619 for E-PASS and 0.842 for POSSUM. The AUC of the E-PASS system increased from 0.588 to 0.694 with the Modified E-PASS equation. The POSSUM system may be more useful than the E-PASS system for estimating postoperative surgical risk in patients undergoing spine surgery. The preoperative risk scores of E-PASS and POSSUM can be useful for predicting postoperative major complications. To enhance the predictability of the scoring systems, using of modified equations based on spine surgery-specific factors may help ensure surgical outcomes and patient safety. Copyright © 2017. Published by Elsevier Inc.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nielsen, Yousef W., E-mail: yujwni01@heh.regionh.d; Eiberg, Jonas P.; Logager, Vibeke B.

    The purpose of this investigation was to determine if addition of infragenicular steady-state (SS) magnetic resonance angiography (MRA) to first-pass imaging improves diagnostic performance compared with first-pass imaging alone in patients with peripheral arterial disease (PAD) undergoing whole-body (WB) MRA. Twenty consecutive patients with PAD referred to digital-subtraction angiography (DSA) underwent WB-MRA. Using a bolus-chase technique, first-pass WB-MRA was performed from the supra-aortic vessels to the ankles. The blood-pool contrast agent gadofosveset trisodium was used at a dose of 0.03 mmol/kg body weight. Ten minutes after injection of the contrast agent, high-resolution (0.7-mm isotropic voxels) SS-MRA of the infragenicular arteriesmore » was performed. Using DSA as the 'gold standard,' sensitivities and specificities for detecting significant arterial stenoses ({>=}50% luminal narrowing) with first-pass WB-MRA, SS-MRA, and combined first-pass and SS-MRA were calculated. Kappa statistics were used to determine intermodality agreement between MRA and DSA. Overall sensitivity and specificity for detecting significant arterial stenoses with first-pass WB-MRA was 0.70 (95% confidence interval 0.61 to 0.78) and 0.97 (0.94 to 0.99), respectively. In first-pass WB-MRA, the lowest sensitivity was in the infragenicular region, with a value of 0.42 (0.23 to 0.63). Combined analysis of first-pass WB-MRA and SS-MRA increased sensitivity to 0.81 (0.60 to 0.93) in the infragenicular region, with specificity of 0.94 (0.88 to 0.97). Sensitivity and specificity for detecting significant arterial stenoses with isolated infragenicular SS-MRA was 0.47 (0.27 to 0.69) and 0.86 (0.78 to 0.91), respectively. Intermodality agreement between MRA and DSA in the infragenicular region was moderate for first-pass WB-MRA ({kappa} = 0.49), fair for SS-MRA ({kappa} = 0.31), and good for combined first-pass/SS-MRA ({kappa} = 0.71). Addition of infragenicular SS-MRA to first-pass WB MRA improves diagnostic performance.« less

  10. Wave-optics simulation of the double-pass beam propagation in modulating retro-reflector FSO systems using a corner cube reflector.

    PubMed

    Yang, Guowei; You, Shengzui; Bi, Meihua; Fan, Bing; Lu, Yang; Zhou, Xuefang; Li, Jing; Geng, Hujun; Wang, Tianshu

    2017-09-10

    Free-space optical (FSO) communication utilizing a modulating retro-reflector (MRR) is an innovative way to convey information between the traditional optical transceiver and the semi-passive MRR unit that reflects optical signals. The reflected signals experience turbulence-induced fading in the double-pass channel, which is very different from that in the traditional single-pass FSO channel. In this paper, we consider the corner cube reflector (CCR) as the retro-reflective device in the MRR. A general geometrical model of the CCR is established based on the ray tracing method to describe the ray trajectory inside the CCR. This ray tracing model could treat the general case that the optical beam is obliquely incident on the hypotenuse surface of the CCR with the dihedral angle error and surface nonflatness. Then, we integrate this general CCR model into the wave-optics (WO) simulation to construct the double-pass beam propagation simulation. This double-pass simulation contains the forward propagation from the transceiver to the MRR through the atmosphere, the retro-reflection of the CCR, and the backward propagation from the MRR to the transceiver, which can be realized by a single-pass WO simulation, the ray tracing CCR model, and another single-pass WO simulation, respectively. To verify the proposed CCR model and double-pass WO simulation, the effective reflection area, the incremental phase, and the reflected beam spot on the transceiver plane of the CCR are analyzed, and the numerical results are in agreement with the previously published results. Finally, we use the double-pass WO simulation to investigate the double-pass channel in the MRR FSO systems. The histograms of the turbulence-induced fading in the forward and backward channels are obtained from the simulation data and are fitted by gamma-gamma (ΓΓ) distributions. As the two opposite channels are highly correlated, we model the double-pass channel fading by the product of two correlated ΓΓ random variables (RVs).

  11. A multicenter prospective study of surgical audit systems.

    PubMed

    Haga, Yoshio; Ikejiri, Koji; Wada, Yasuo; Takahashi, Tadateru; Ikenaga, Masakazu; Akiyama, Noriyoshi; Koike, Shoichiro; Koseki, Masato; Saitoh, Toshihiro

    2011-01-01

    This study was undertaken to evaluate a modified form of Estimation of Physiologic Ability and Surgical Stress (E-PASS) for surgical audit comparing with other existing models. Although several scoring systems have been devised for surgical audit, no nation-wide survey has been performed yet. We modified our previous E-PASS surgical audit system by computing the weights of 41 procedures, using data from 4925 patients who underwent elective digestive surgery, designated it as mE-PASS. Subsequently, a prospective cohort study was conducted in 43 national hospitals in Japan from April 1, 2005, to April 8, 2007. Variables for the E-PASS and American Society of Anesthesiologists (ASA) status-based model were collected for 5272 surgically treated patients. Of the 5272 patients, we also collected data for the Portsmouth modification of Physiologic and Operative Severity Score for the enUmeration of Mortality and morbidity (P-POSSUM) in 3128 patients. The area under the receiver operative characteristic curve (AUC) was used to evaluate discrimination performance to detect in-hospital mortality. The ratio of observed to estimated in-hospital mortality rates (OE ratio) was defined as a measure of quality. The numbers of variables required were 10 for E-PASS, 7 for mE-PASS, 20 for P-POSSUM, and 4 for the ASA status-based model. The AUC (95% confidence interval) values were 0.86 (0.79-0.93) for E-PASS, 0.86 (0.79-0.92) for mE-PASS, 0.81 (0.75-0.88) for P-POSSUM, and 0.73 (0.63-0.83) for the ASA status-based model. The OE ratios for mE-PASS among large-volume hospitals significantly correlated with those for E-PASS (R = 0.93, N = 9, P = 0.00026), P-POSSUM (R = 0.96, N = 6, P = 0.0021), and ASA status-based model (R = 0.83, N = 9, P = 0.0051). Because of its features of easy use, accuracy, and generalizability, mE-PASS is a candidate for a nation-wide survey.

  12. Khyber Pass, Afghanistan-Pakistan

    NASA Image and Video Library

    2010-11-08

    The ASTER instrument onboard NASA Terra spacecraft imaged the Khyber Pass, a mountain pass that links Afghanistan and Pakistan. Throughout its history it has been an important trade route between Central Asia and South Asia.

  13. Band-pass filtering algorithms for adaptive control of compressor pre-stall modes in aircraft gas-turbine engine

    NASA Astrophysics Data System (ADS)

    Kuznetsova, T. A.

    2018-05-01

    The methods for increasing gas-turbine aircraft engines' (GTE) adaptive properties to interference based on empowerment of automatic control systems (ACS) are analyzed. The flow pulsation in suction and a discharge line of the compressor, which may cause the stall, are considered as the interference. The algorithmic solution to the problem of GTE pre-stall modes’ control adapted to stability boundary is proposed. The aim of the study is to develop the band-pass filtering algorithms to provide the detection functions of the compressor pre-stall modes for ACS GTE. The characteristic feature of pre-stall effect is the increase of pressure pulsation amplitude over the impeller at the multiples of the rotor’ frequencies. The used method is based on a band-pass filter combining low-pass and high-pass digital filters. The impulse response of the high-pass filter is determined through a known low-pass filter impulse response by spectral inversion. The resulting transfer function of the second order band-pass filter (BPF) corresponds to a stable system. The two circuit implementations of BPF are synthesized. Designed band-pass filtering algorithms were tested in MATLAB environment. Comparative analysis of amplitude-frequency response of proposed implementation allows choosing the BPF scheme providing the best quality of filtration. The BPF reaction to the periodic sinusoidal signal, simulating the experimentally obtained pressure pulsation function in the pre-stall mode, was considered. The results of model experiment demonstrated the effectiveness of applying band-pass filtering algorithms as part of ACS to identify the pre-stall mode of the compressor for detection of pressure fluctuations’ peaks, characterizing the compressor’s approach to the stability boundary.

  14. Physical and hydrologic characteristics of Matlacha Pass, southwestern Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kane, R.L.; Russell, G.M.

    1994-03-01

    Matlacha Pass is part of the connected inshore waters of the Charlotte Harbor estuary in southwestern Florida. Bathymetry indicates that depths in the main channel of the pass range from 4 to 14 feet below sea level. The channel averages about 8 feet deep in the northern part of the pass and about 5 feet deep in the southern part. Additionally, depths average about 4 feet in a wide section of the middle of the pass and about 2 feet along the mangrove swamps near the shoreline. Tidal flow within Matlacha Pass varies depending on aquatic vegetation densities, oyster beds,more » and tidal flats. Surface-water runoff occurs primarily during the wet season (May to September), with most of the flow entering the Matlacha Pass through two openings in the spreader canal system near the city of Matlacha. Freshwater flow into the pass from the north Cape Coral spreader canal system averaged 113 cubic feet per second from October 1987 to September 1992. Freshwater inflow from the Aries Canal of the south Cape Coral spreader canal system averaged 14.1 cubic feet per second from October 1989 to September 1992. Specific conductance throughout Matlacha Pass ranged from less than 1,000 to 57,000 microsiemens per centimeter. Specific conductance, collected from a continuous monitoring data logger in the middle of the pass from February to September 1992, averaged 36,000 microsiemens per centimeter at 2 feet below the water surface and 40,000 microsiemens per centimeter at 2 feet above the bottom. During both the wet and dry seasons, specific conductance indicated that the primary mixing of tidal waters and freshwater inflow occurs in the mangrove swamps along the shoreline.« less

  15. Coaxial charged particle energy analyzer

    NASA Technical Reports Server (NTRS)

    Kelly, Michael A. (Inventor); Bryson, III, Charles E. (Inventor); Wu, Warren (Inventor)

    2011-01-01

    A non-dispersive electrostatic energy analyzer for electrons and other charged particles having a generally coaxial structure of a sequentially arranged sections of an electrostatic lens to focus the beam through an iris and preferably including an ellipsoidally shaped input grid for collimating a wide acceptance beam from a charged-particle source, an electrostatic high-pass filter including a planar exit grid, and an electrostatic low-pass filter. The low-pass filter is configured to reflect low-energy particles back towards a charged particle detector located within the low-pass filter. Each section comprises multiple tubular or conical electrodes arranged about the central axis. The voltages on the lens are scanned to place a selected energy band of the accepted beam at a selected energy at the iris. Voltages on the high-pass and low-pass filters remain substantially fixed during the scan.

  16. An Artificial Intelligence Approach to Automatic Left Ventricular Border Detection in 2-D Echocardiography

    PubMed Central

    Buchan, Iris; Covvey, H. Dominic; Rakowski, Harry

    1985-01-01

    A program has been developed for left ventricular (LV) border tracking on ultrasound images. For each frame, forty border points at equally-spaced angles around the LV center are found gradually during three passes. Pass 1 uses adaptive thresholding to find the most obvious border points. Pass 2 then uses an artificial intelligence technique of finding possible border path segments, associating a score with each, and, from paths with superior scores, obtaining more of the border points. Pass 3 closes any remaining gaps by interpolation. The program tracks the LV border quite well in spite of dropout and interference from intracardiac structures, except during end-systole. Multi-level passes provide a very useful structure for border tracking, with increasingly slow but more sophisticated algorithms possible at higher levels for use when earlier passes recognise failure.

  17. New Models for Protocol Security

    DTIC Science & Technology

    2015-06-18

    Rafael Pass, Alon Rosen , Eylon Yogev: One- Way Functions and (Im)Perfect Obfuscation. FOCS 2014: 374-383 14. Joseph Y. Halpern, Rafael Pass, Lior Seeman...Conservative belief and rationality. Games and Economic Behavior 80: 186-192 (2013) 21. Rafael Pass, Alon Rosen , Wei-Lung Dustin Tseng: Public-Coin...Pass, Wei-Lung Dustin Tseng: The Knowledge Tightness of Par- allel Zero-Knowledge. TCC 2012: 512-529 44. Boaz Barak , Ran Canetti, Yehuda Lindell, Rafael

  18. Synchrotron X-ray microbeam diffraction measurements of full elastic long range internal strain and stress tensors in commercial-purity aluminum processed by multiple passes of equal-channel angular pressing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phan, Thien Q.; Levine, Lyle E.; Lee, I-Fang

    Synchrotron X-ray microbeam diffraction was used to measure the full elastic long range internal strain and stress tensors of low dislocation density regions within the submicrometer grain/subgrain structure of equal-channel angular pressed (ECAP) aluminum alloy AA1050 after 1, 2, and 8 passes using route B C. This is the first time that full tensors were measured in plastically deformed metals at this length scale. The maximum (most tensile or least compressive) principal elastic strain directions for the unloaded 1 pass sample for the grain/subgrain interiors align well with the pressing direction, and are more random for the 2 and 8more » pass samples. The measurements reported here indicate that the local stresses and strains become increasingly isotropic (homogenized) with increasing ECAP passes using route BC. The average maximum (in magnitude) LRISs are -0.43 σ a for 1 pass, -0.44 σ a for 2 pass, and 0.14 σ a for the 8 pass sample. Furthermore, these LRISs are larger than those reported previously because those earlier measurements were unable to measure the full stress tensor. Significantly, the measured stresses are inconsistent with the two-component composite model.« less

  19. MOBILE GAMMA IRRADIATORS FOR FRUIT PRODUCE (Engineering Materials)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1963-10-31

    Mobile irradiators used for the radiopasteurization of strawberries, grapes, peaches, tomatoes, and lemons are described. The irradiators are mounted on trailers and each irradiator, including the trailer, weighs 70 to 80 tons. Radiatton doses range from 100,000 to 200,000 rads. Minimum production is 500 lb of fruit per hour. Drawings are included for four types of irradiators: the single-slab twopass, double-slab one-pass, single-slab four-pass, and line-source rotary. In the single-slab two-pass system, the packages make two passes in front of the source. The length of the packages is parallel to the direction of travel. The packages are irradiated on eachmore » side. This system is light in weight, has low capital cost, and is simple to fabricate. The double-slab one- pass system is the same as the above except the source strength is doubled and irradiation time is cut in half. The same arrangement is used in the single-slab four-pass system that is used in the singleslab two-pass system except the packages make two passes on each side of the source. The rotary system combines a linear and rotary motion to provide high dosage. It uses a small Co/sup 60/ source but costs more than a single-slab twopass system. (F.E.S.)« less

  20. Relationship between High School Mathematics Grade and Number of Attempts Required to Pass the Medication Calculation Test in Nurse Education: An Explorative Study

    PubMed Central

    Alteren, Johanne; Nerdal, Lisbeth

    2015-01-01

    In Norwegian nurse education, students are required to achieve a perfect score in a medication calculation test before undertaking their first practice period during the second semester. Passing the test is a challenge, and students often require several attempts. Adverse events in medication administration can be related to poor mathematical skills. The purpose of this study was to explore the relationship between high school mathematics grade and the number of attempts required to pass the medication calculation test in nurse education. The study used an exploratory design. The participants were 90 students enrolled in a bachelor’s nursing program. They completed a self-report questionnaire, and statistical analysis was performed. The results provided no basis for the conclusion that a statistical relationship existed between high school mathematics grade and number of attempts required to pass the medication calculation test. Regardless of their grades in mathematics, 43% of the students passed the medication calculation test on the first attempt. All of the students who had achieved grade 5 had passed by the third attempt. High grades in mathematics were not crucial to passing the medication calculation test. Nonetheless, the grade may be important in ensuring a pass within fewer attempts. PMID:27417767

  1. Synchrotron X-ray microbeam diffraction measurements of full elastic long range internal strain and stress tensors in commercial-purity aluminum processed by multiple passes of equal-channel angular pressing

    DOE PAGES

    Phan, Thien Q.; Levine, Lyle E.; Lee, I-Fang; ...

    2016-04-23

    Synchrotron X-ray microbeam diffraction was used to measure the full elastic long range internal strain and stress tensors of low dislocation density regions within the submicrometer grain/subgrain structure of equal-channel angular pressed (ECAP) aluminum alloy AA1050 after 1, 2, and 8 passes using route B C. This is the first time that full tensors were measured in plastically deformed metals at this length scale. The maximum (most tensile or least compressive) principal elastic strain directions for the unloaded 1 pass sample for the grain/subgrain interiors align well with the pressing direction, and are more random for the 2 and 8more » pass samples. The measurements reported here indicate that the local stresses and strains become increasingly isotropic (homogenized) with increasing ECAP passes using route BC. The average maximum (in magnitude) LRISs are -0.43 σ a for 1 pass, -0.44 σ a for 2 pass, and 0.14 σ a for the 8 pass sample. Furthermore, these LRISs are larger than those reported previously because those earlier measurements were unable to measure the full stress tensor. Significantly, the measured stresses are inconsistent with the two-component composite model.« less

  2. Pass-transistor very large scale integration

    NASA Technical Reports Server (NTRS)

    Maki, Gary K. (Inventor); Bhatia, Prakash R. (Inventor)

    2004-01-01

    Logic elements are provided that permit reductions in layout size and avoidance of hazards. Such logic elements may be included in libraries of logic cells. A logical function to be implemented by the logic element is decomposed about logical variables to identify factors corresponding to combinations of the logical variables and their complements. A pass transistor network is provided for implementing the pass network function in accordance with this decomposition. The pass transistor network includes ordered arrangements of pass transistors that correspond to the combinations of variables and complements resulting from the logical decomposition. The logic elements may act as selection circuits and be integrated with memory and buffer elements.

  3. Possibilities of the fish pass restoration

    NASA Astrophysics Data System (ADS)

    Čubanová, Lea

    2018-03-01

    According to the new elaborated methodology of the Ministry of Environment of the Slovak Republic: Identification of the appropriate fish pass types according to water body typology (2015) each barrier on the river must be passable. On the barriers or structures without fish passes new ones should be design and built and on some water structures with existed but nonfunctional fish passes must be realized reconstruction or restoration of such objects. Assessment should be done in terms of the existing migratory fish fauna and hydraulic conditions. Fish fauna requirements resulting from the ichthyological research of the river section with barrier. Hydraulic conditions must than fulfil these requirements inside the fish pass body.

  4. Intel NX to PVM 3.2 message passing conversion library

    NASA Technical Reports Server (NTRS)

    Arthur, Trey; Nelson, Michael L.

    1993-01-01

    NASA Langley Research Center has developed a library that allows Intel NX message passing codes to be executed under the more popular and widely supported Parallel Virtual Machine (PVM) message passing library. PVM was developed at Oak Ridge National Labs and has become the defacto standard for message passing. This library will allow the many programs that were developed on the Intel iPSC/860 or Intel Paragon in a Single Program Multiple Data (SPMD) design to be ported to the numerous architectures that PVM (version 3.2) supports. Also, the library adds global operations capability to PVM. A familiarity with Intel NX and PVM message passing is assumed.

  5. Statistical variability and confidence intervals for planar dose QA pass rates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bailey, Daniel W.; Nelms, Benjamin E.; Attwood, Kristopher

    Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics ofmore » various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.« less

  6. 48 CFR 2415.304 - Evaluation factors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... assigned a numerical weight (except for pass-fail factors) which shall appear in the RFP. When using LPTA, each evaluation factor is applied on a “pass-fail” basis; numerical scores are not assigned. “Pass-fail...

  7. 48 CFR 2415.304 - Evaluation factors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... assigned a numerical weight (except for pass-fail factors) which shall appear in the RFP. When using LPTA, each evaluation factor is applied on a “pass-fail” basis; numerical scores are not assigned. “Pass-fail...

  8. The Pattern of Indoor Smoking Restriction Law Transitions, 1970–2009: Laws Are Sticky

    PubMed Central

    Sanders-Jackson, Ashley; Gonzalez, Mariaelena; Zerbe, Brandon; Song, Anna V.

    2013-01-01

    Objectives. We examined the pattern of the passage of smoking laws across venues (government and private workplaces, restaurants, bars) and by strength (no law to 100% smoke-free). Methods. We conducted transition analyses of local and state smoking restrictions passed between 1970 and 2009, with data from the Americans for Nonsmokers’ Rights Ordinance Database. Results. Each decade, more laws were enacted, from 18 passed in the 1970s to 3172 in the first decade of this century, when 91% of existing state laws were passed. Most laws passed took states and localities from no law to some level of smoking restriction, and most new local (77%; 5148/6648) and state (73%; 115/158) laws passed in the study period did not change strength. Conclusions. Because these laws are “sticky”—once a law has passed, strength of the law and venues covered do not change often—policymakers and advocates should focus on passing strong laws the first time, rather than settling for less comprehensive laws with the hope of improving them in the future. PMID:23763408

  9. Precipitation behavior of σ phase in fusion zone of dissimilar stainless steel welds during multi-pass GTAW process

    NASA Astrophysics Data System (ADS)

    Hsieh, Chih-Chun; Chang, Tao-Chih; Lin, Dong-Yih; Chen, Ming-Che; Wu, Weite

    2007-10-01

    The purpose of this study is to investigate the precipitation characteristics of σ phase in the fusion zone of stainless steel welds at various welding passes during a tungsten are welding (GTAW) process. The morphology, quantity, and chemical composition of the δ-ferrite and σ phase were analyzed using optical microscopy (OM), a ferritscope (FS), a X-ray diffractometer (XRD), scanning electron microscopy (SEM), an electron probe micro-analyzer (EPMA), and a wavelength dispersive spectrometer (WDS), respectively. Massive δ-ferrite was observed in the fusion zone of the first pass welds during welding of dissimilar stainless steels. The σ phase precipitated at the inner δ-ferrite particles and decreased δ-ferrite content during the third pass welding. The σ and δ phases can be stabilized by Si element, which promoted the phase transformation of σ→ϱ+λ2 in the fusion zone of the third pass welds. It was found that the σ phase was a Fe-Cr-Si intermetallic compound found in the fusion zone of the third pass welds during multi-pass welding.

  10. Fabrication of seamless calandria tubes by cold pilgering route using 3-pass and 2-pass schedules

    NASA Astrophysics Data System (ADS)

    Saibaba, N.

    2008-12-01

    Calandria tube is a large diameter, extremely thin walled zirconium alloy tube which has diameter to wall thickness ratio as high as 90-95. Such tubes are conventionally produced by the 'welded route', which involves extrusion of slabs followed by a series of hot and cold rolling passes, intermediate anneals, press forming of sheets into circular shape and closing the gap by TIG welding. Though pilgering is a well established process for the fabrication of seamless tubes, production of extremely thin walled tubes offers several challenges during pilgering. Nuclear fuel complex (NFC), Hyderabad, has successfully developed a process for the production of Zircaloy-4 calandria tubes by adopting the 'seamless route' which involves hot extrusion of mother blanks followed by three-pass pilgering or two-pass pilgering schedules. This paper deals with standardization of the seamless route processes for fabrication of calandria tubes, comparison between the tubes produced by 2-pass and 3-pass pilgering schedules, role of ultrasonic test charts for control of process parameters, development of new testing methods for burst testing and other properties.

  11. Bozeman Pass post-fencing wildlife monitoring.

    DOT National Transportation Integrated Search

    2010-12-01

    The Bozeman Pass transportation corridor between Bozeman and Livingston, Montana, includes Interstate 90 (I-90), frontage roads, : and a railroad. The highway was a suspected barrier and hazard to animal movement in the Bozeman Pass area, which is co...

  12. The Objective Borderline Method (OBM): A Probability-Based Model for Setting up an Objective Pass/Fail Cut-Off Score in Medical Programme Assessments

    ERIC Educational Resources Information Center

    Shulruf, Boaz; Turner, Rolf; Poole, Phillippa; Wilkinson, Tim

    2013-01-01

    The decision to pass or fail a medical student is a "high stakes" one. The aim of this study is to introduce and demonstrate the feasibility and practicality of a new objective standard-setting method for determining the pass/fail cut-off score from borderline grades. Three methods for setting up pass/fail cut-off scores were compared: the…

  13. Combinatorial games with a pass: a dynamical systems approach.

    PubMed

    Morrison, Rebecca E; Friedman, Eric J; Landsberg, Adam S

    2011-12-01

    By treating combinatorial games as dynamical systems, we are able to address a longstanding open question in combinatorial game theory, namely, how the introduction of a "pass" move into a game affects its behavior. We consider two well known combinatorial games, 3-pile Nim and 3-row Chomp. In the case of Nim, we observe that the introduction of the pass dramatically alters the game's underlying structure, rendering it considerably more complex, while for Chomp, the pass move is found to have relatively minimal impact. We show how these results can be understood by recasting these games as dynamical systems describable by dynamical recursion relations. From these recursion relations, we are able to identify underlying structural connections between these "games with passes" and a recently introduced class of "generic (perturbed) games." This connection, together with a (non-rigorous) numerical stability analysis, allows one to understand and predict the effect of a pass on a game.

  14. Comparing NET and ERI standardized exam scores between baccalaureate graduates who pass or fail the NCLEX-RN.

    PubMed

    Bondmass, Mary D; Moonie, Sheniz; Kowalski, Susan

    2008-01-01

    In the United States, nursing programs are commonly evaluated by their graduates success on the National Council Licensure Examination for Registered Nurses (NCLEX-RN). The purpose of this paper is to describe a change in NCLEX-RN success rates following the addition of standardized exams throughout our program's curriculum, and to compare these exam scores between graduates who pass NCLEX-RN and those who do not. Our results indicate an 8.5% change (p < 0.000) in the NCLEX-RN pass rate from our previous 5-year mean pass rate, and significant differences in standardized test scores for those who pass the NCLEX-RN compared to those who do not (p < 0.03). We conclude that our selected standardized exam scores are able to significantly identify graduates who are more likely to pass NCLEX-RN than not.

  15. The volumetric flux through Deception Pass, Washington and its effects on the circulation in the Whidbey Basin.

    NASA Astrophysics Data System (ADS)

    Heinze, K. R.

    2002-05-01

    The volumetric flux through Deception Pass, Washington will be determined by using tidal height differences between Bowman and Cornet Bays, which are located on the seaward and landward sides of Deception Pass respectively in Deception Pass State Park. Hydrolab sensors for measuring temperature, salinity and fluid depth will be attached to public boat docks in each of these bays. The numerical Puget Sound Regional Synthesis Model, PRISM, will be run with and without the flux through Deception Pass and compared to determine theoretically whether or not the flow through Deception Pass plays a significant role in the circulation of the Whidbey Basin, which could affect the circulation in the northern part of the Main Basin known as the Triple Junction. This could influence water movement near the new sewer outfall that King County is proposing to build in that area.

  16. Heating and cooling system for an on-board gas adsorbent storage vessel

    DOEpatents

    Tamburello, David A.; Anton, Donald L.; Hardy, Bruce J.; Corgnale, Claudio

    2017-06-20

    In one aspect, a system for controlling the temperature within a gas adsorbent storage vessel of a vehicle may include an air conditioning system forming a continuous flow loop of heat exchange fluid that is cycled between a heated flow and a cooled flow. The system may also include at least one fluid by-pass line extending at least partially within the gas adsorbent storage vessel. The fluid by-pass line(s) may be configured to receive a by-pass flow including at least a portion of the heated flow or the cooled flow of the heat exchange fluid at one or more input locations and expel the by-pass flow back into the continuous flow loop at one or more output locations, wherein the by-pass flow is directed through the gas adsorbent storage vessel via the by-pass line(s) so as to adjust an internal temperature within the gas adsorbent storage vessel.

  17. Four-Pass Coupler for Laser-Diode-Pumped Solid-State Laser

    NASA Technical Reports Server (NTRS)

    Coyle, Donald B.

    2008-01-01

    A four-pass optical coupler affords increased (in comparison with related prior two-pass optical couplers) utilization of light generated by a laser diode in side pumping of a solid-state laser slab. The original application for which this coupler was conceived involves a neodymium-doped yttrium aluminum garnet (Nd:YAG) crystal slab, which, when pumped by a row of laser diodes at a wavelength of 809 nm, lases at a wavelength of 1,064 nm. Heretofore, typically, a thin laser slab has been pumped in two passes, the second pass occurring by virtue of reflection of pump light from a highly reflective thin film on the side opposite the side through which the pump light enters. In two-pass pumping, a Nd:YAG slab having a thickness of 2 mm (which is typical) absorbs about 84 percent of the 809-nm pump light power, leaving about 16 percent of the pump light power to travel back toward the laser diodes. This unused power can cause localized heating of the laser diodes, thereby reducing their lifetimes. Moreover, if the slab is thinner than 2 mm, then even more unused power travels back toward the laser diodes. The four-pass optical coupler captures most of this unused pump light and sends it back to the laser slab for two more passes. As a result, the slab absorbs more pump light, as though it were twice as thick. The gain and laser cavity beam quality of a smaller laser slab in conjunction with this optical coupler can thus be made comparable to those of a larger two-pass-pumped laser slab.

  18. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results.

    PubMed

    Ari-Even Roth, Daphne; Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-12-06

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. © The Author(s) 2016.

  19. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results

    PubMed Central

    Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-01-01

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. PMID:27927982

  20. Modeling of the static recrystallization for 7055 aluminum alloy by cellular automaton

    NASA Astrophysics Data System (ADS)

    Zhang, Tao; Lu, Shi-hong; Zhang, Jia-bin; Li, Zheng-fang; Chen, Peng; Gong, Hai; Wu, Yun-xin

    2017-09-01

    In order to simulate the flow behavior and microstructure evolution during the pass interval period of the multi-pass deformation process, models of static recovery (SR) and static recrystallization (SRX) by the cellular automaton (CA) method for the 7055 aluminum alloy were established. Double-pass hot compression tests were conducted to acquire flow stress and microstructure variation during the pass interval period. With the basis of the material constants obtained from the compression tests, models of the SR, incubation period, nucleation rate and grain growth were fitted by least square method. A model of the grain topology and a statistical computation of the CA results were also introduced. The effects of the pass interval time, temperature, strain, strain rate and initial grain size on the microstructure variation for the SRX of the 7055 aluminum alloy were studied. The results show that a long pass interval time, large strain, high temperature and large strain rate are beneficial for finer grains during the pass interval period. The stable size of the static recrystallized grain is not concerned with the initial grain size, but mainly depends on the strain rate and temperature. The SRX plays a vital role in grain refinement, while the SR has no effect on the variation of microstructure morphology. Using flow stress and microstructure comparisons of the simulated and experimental CA results, the established CA models can accurately predict the flow stress and microstructure evolution during the pass interval period, and provide guidance for the selection of optimized parameters for the multi-pass deformation process.

  1. 75 FR 60423 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-30

    ... November 1, 2010. Title and OMB Number: DoD Building Pass Application; DD Form 2249; OMB Number 0704-0328... applicants for DoD Building Passes. The information collected from the DD Form 2249, ``DoD Building Pass...

  2. Sequential Participation in a Multi-Institutional Mock Oral Examination Is Associated With Improved American Board of Surgery Certifying Examination First-Time Pass Rate.

    PubMed

    Fingeret, Abbey L; Arnell, Tracey; McNelis, John; Statter, Mindy; Dresner, Lisa; Widmann, Warren

    We sought to determine whether sequential participation in a multi-institutional mock oral examination affected the likelihood of passing the American Board of Surgery Certifying Examination (ABSCE) in first attempt. Residents from 3 academic medical centers were able to participate in a regional mock oral examination in the fall and spring of their fourth and fifth postgraduate year from 2011 to 2014. Candidate׳s highest composite score of all mock orals attempts was classified as risk for failure, intermediate, or likely to pass. Factors including United States Medical Licensing Examination steps 1, 2, and 3, number of cases logged, American Board of Surgery In-Training Examination performance, American Board of Surgery Qualifying Examination (ABSQE) performance, number of attempts, and performance in the mock orals were assessed to determine factors predictive of passing the ABSCE. A total of 128 mock oral examinations were administered to 88 (71%) of 124 eligible residents. The overall first-time pass rate for the ABSCE was 82%. There was no difference in pass rates between participants and nonparticipants. Of them, 16 (18%) residents were classified as at risk, 47 (53%) as intermediate, and 25 (29%) as likely to pass. ABSCE pass rate for each group was as follows: 36% for at risk, 84% for intermediate, and 96% for likely pass. The following 4 factors were associated with first-time passing of ABSCE on bivariate analysis: mock orals participation in postgraduate year 4 (p = 0.05), sequential participation in mock orals (p = 0.03), ABSQE performance (p = 0.01), and best performance on mock orals (p = 0.001). In multivariable logistic regression, the following 3 factors remained associated with ABSCE passing: ABSQE performance, odds ratio (OR) = 2.9 (95% CI: 1.3-6.1); mock orals best performance, OR = 1.7 (1.2-2.4); and participation in multiple mock oral examinations, OR = 1.4 (1.1-2.7). Performance on a multi-institutional mock oral examination can identify residents at risk for failure of the ABSCE. Sequential participation in mock oral examinations is associated with improved ABSCE first-time pass rate. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  3. Theoretic derivation of directed acyclic subgraph algorithm and comparisons with message passing algorithm

    NASA Astrophysics Data System (ADS)

    Ha, Jeongmok; Jeong, Hong

    2016-07-01

    This study investigates the directed acyclic subgraph (DAS) algorithm, which is used to solve discrete labeling problems much more rapidly than other Markov-random-field-based inference methods but at a competitive accuracy. However, the mechanism by which the DAS algorithm simultaneously achieves competitive accuracy and fast execution speed, has not been elucidated by a theoretical derivation. We analyze the DAS algorithm by comparing it with a message passing algorithm. Graphical models, inference methods, and energy-minimization frameworks are compared between DAS and message passing algorithms. Moreover, the performances of DAS and other message passing methods [sum-product belief propagation (BP), max-product BP, and tree-reweighted message passing] are experimentally compared.

  4. Aeromagnetic map of the Glacier Peak Wilderness and adjacent areas, Chelan, Skagit, and Snohomish counties, Washington

    USGS Publications Warehouse

    Flanigan, V.J.; Sherrard, Mark

    1985-01-01

    The Glacier Peak Wilderness encompasses 464,741 acres, including 483 acres of patented mining and millsite claims. Also included in the present study are nine areas adjoining the wilderness (see fig. 1), totaling 90,034 acres of recommended wilderness additions. All these lands are here collectively called the “study area.” Access to the study area is provided by generally well maintained trails from gravel or dirt roads along major valleys above Darrington, Marblemount, Stehekin, Holden, Trinity, and Lake Wnatchee. Other than the main access trails across a few passes (Cloudy Pass, Buck Creek Pass, White Pass, and Indian Pass), trails are rough, infrequently maintained, or nonexistent.

  5. Frequency-Domain Characterization of Optic Flow and Vision-Based Ocellar Sensing for Rotational Motion

    DTIC Science & Technology

    2017-04-01

    complementary fusion: Fourth-order Butterworth filter was used to high -pass ocelli and low-pass optic flow. The normalized cutoff frequency had to be kept...information introduced by luminance change. The high - frequency cutoff was added to reject the flickering noise for indoor usage. The filtered signals from the...function of the low- pass filter is to attenuate high - frequency noise. The final band-pass filter transfer function is in Eq. 2. (()

  6. Workability Limits of Magnesium Alloy AZ31B Subjected to Equal Channel Angular Pressing

    NASA Astrophysics Data System (ADS)

    Arun, M. S.; Chakkingal, Uday

    2018-03-01

    Equal channel angular pressing (ECAP) is an important severe plastic deformation process to produce ultrafine grained microstructures in metals and alloys. Magnesium and its alloys generally possess poor workability at temperatures below 250 °C. This investigation examines the influence of different passes and processing routes of ECAP on improving the workability of Mg alloy AZ31B. ECAP was carried out for three passes using a die of angle 120° using processing routes Bc and C. The operating temperature was 523 K for the first pass and 423 K for the subsequent two passes. The resultant microstructure and mechanical properties were determined. Workability of the alloy at 423 K (150 °C) was determined using upsetting experiments on cylindrical specimens machined from the annealed and ECAPed samples. Workability limit diagrams have been constructed for the various processed conditions. The workability data generated were also analyzed using five different workability criteria (also referred to as ductile fracture models) and the material constants for these five models were evaluated. Specimens processed by two passes through route C (pass 2C) exhibits better workability compared to other passes since the workability limit line after this pass shows maximum safe working area and lies above the other workability lines. Among the five different workability criteria investigated, the Freudenthal workability criterion is more suitable for prediction of failure in this alloy.

  7. Efficient flattop ultra-wideband wavelength converters based on double-pass cascaded sum and difference frequency generation using engineered chirped gratings.

    PubMed

    Tehranchi, Amirhossein; Morandotti, Roberto; Kashyap, Raman

    2011-11-07

    High-efficiency ultra-broadband wavelength converters based on double-pass quasi-phase-matched cascaded sum and difference frequency generation including engineered chirped gratings in lossy lithium niobate waveguides are numerically investigated and compared to the single-pass counterparts, assuming a large twin-pump wavelength difference of 75 nm. Instead of uniform gratings, few-section chirped gratings with the same length, but with a small constant period change among sections with uniform gratings, are proposed to flatten the response and increase the mean efficiency by finding the common critical period shift and minimum number of sections for both single-pass and double-pass schemes whilst for the latter the efficiency is remarkably higher in a low-loss waveguide. It is also verified that for the same waveguide length and power, the efficiency enhancement expected due to the use of the double-pass scheme instead of the single-pass one, is finally lost if the waveguide loss increases above a certain value. For the double-pass scheme, the criteria for the design of the low-loss waveguide length, and the assignment of power in the pumps to achieve the desired efficiency, bandwidth and ripple are presented for the optimum 3-section chirped-gratings-based devices. Efficient conversions with flattop bandwidths > 84 nm for lengths < 3 cm can be obtained.

  8. "Which pass is better?" Novel approaches to assess passing effectiveness in elite soccer.

    PubMed

    Rein, Robert; Raabe, Dominik; Memmert, Daniel

    2017-10-01

    Passing behaviour is a key property of successful performance in team sports. Previous investigations however have mainly focused on notational measurements like total passing frequencies which provide little information about what actually constitutes successful passing behaviour. Consequently, this has hampered the transfer of research findings into applied settings. Here we present two novel approaches to assess passing effectiveness in elite soccer by evaluating their effects on majority situations and space control in front of the goal. Majority situations are assessed by calculating the number of defenders between the ball carrier and the goal. Control of space is estimated using Voronoi-diagrams based on the player's positions on the pitch. Both methods were applied to position data from 103 German First division games from the 2011/2012, 2012/2013 and 2014/2015 seasons using a big data approach. The results show that both measures are significantly related to successful game play with respect to the number of goals scored and to the probability of winning a game. The results further show that on average passes from the mid-field into the attacking area are most effective. The presented passing efficiency measures thereby offer new opportunities for future applications in soccer and other sports disciplines whilst maintaining practical relevance with respect to tactical training regimes or game performances analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Distributed Offline Data Reconstruction in BaBar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pulliam, Teela M

    The BaBar experiment at SLAC is in its fourth year of running. The data processing system has been continuously evolving to meet the challenges of higher luminosity running and the increasing bulk of data to re-process each year. To meet these goals a two-pass processing architecture has been adopted, where 'rolling calibrations' are quickly calculated on a small fraction of the events in the first pass and the bulk data reconstruction done in the second. This allows for quick detector feedback in the first pass and allows for the parallelization of the second pass over two or more separate farms.more » This two-pass system allows also for distribution of processing farms off-site. The first such site has been setup at INFN Padova. The challenges met here were many. The software was ported to a full Linux-based, commodity hardware system. The raw dataset, 90 TB, was imported from SLAC utilizing a 155 Mbps network link. A system for quality control and export of the processed data back to SLAC was developed. Between SLAC and Padova we are currently running three pass-one farms, with 32 CPUs each, and nine pass-two farms with 64 to 80 CPUs each. The pass-two farms can process between 2 and 4 million events per day. Details about the implementation and performance of the system will be presented.« less

  10. Influences of Friction Stir Welding Parameters on Microstructural and Mechanical Properties of AA5456 (AlMg5) at Different Lap Joint Thicknesses

    NASA Astrophysics Data System (ADS)

    Pishevar, M. R.; Mohandesi, J. Aghazadeh; Omidvar, H.; Safarkhanian, M. A.

    2015-10-01

    Friction stir welding is suitable for joining series 5000 alloys because no fusion welding problems arise for the alloys in this process. The present study examined the effects of double-pass welding and tool rotational and travel speeds for the second-pass welding on the mechanical and microstructural properties of friction stir lap welding of AA5456 (AlMg5)-H321 (5 mm thickness) and AA5456 (AlMg5)-O (2.5 mm thickness). The first pass of all specimens was performed at a rotational speed of 650 rpm and a travel speed of 50 mm/min. The second pass was performed at rotational speeds of 250, 450, and 650 rpm and travel speeds of 25, 50, and 75 mm/min. The results showed that the second pass changed the grain sizes in the center of the nugget zone compared with the first pass. It was observed that the size of the hooking defect of the double-pass-welded specimens was higher than that for the single-pass-welded specimen. The size of the hooking defect was found to be a function of the rotational and travel speeds. The optimal joint tensile shear properties were achieved at a rotational speed of 250 rpm and travel a speed of 75 mm/min.

  11. Reversible wavelet filter banks with side informationless spatially adaptive low-pass filters

    NASA Astrophysics Data System (ADS)

    Abhayaratne, Charith

    2011-07-01

    Wavelet transforms that have an adaptive low-pass filter are useful in applications that require the signal singularities, sharp transitions, and image edges to be left intact in the low-pass signal. In scalable image coding, the spatial resolution scalability is achieved by reconstructing the low-pass signal subband, which corresponds to the desired resolution level, and discarding other high-frequency wavelet subbands. In such applications, it is vital to have low-pass subbands that are not affected by smoothing artifacts associated with low-pass filtering. We present the mathematical framework for achieving 1-D wavelet transforms that have a spatially adaptive low-pass filter (SALP) using the prediction-first lifting scheme. The adaptivity decisions are computed using the wavelet coefficients, and no bookkeeping is required for the perfect reconstruction. Then, 2-D wavelet transforms that have a spatially adaptive low-pass filter are designed by extending the 1-D SALP framework. Because the 2-D polyphase decompositions are used in this case, the 2-D adaptivity decisions are made nonseparable as opposed to the separable 2-D realization using 1-D transforms. We present examples using the 2-D 5/3 wavelet transform and their lossless image coding and scalable decoding performances in terms of quality and resolution scalability. The proposed 2-D-SALP scheme results in better performance compared to the existing adaptive update lifting schemes.

  12. Investigation of the effects of sleeper-passing impacts on the high-speed train

    NASA Astrophysics Data System (ADS)

    Wu, Xingwen; Cai, Wubin; Chi, Maoru; Wei, Lai; Shi, Huailong; Zhu, Minhao

    2015-12-01

    The sleeper-passing impact has always been considered negligible in normal conditions, while the experimental data obtained from a High-speed train in a cold weather expressed significant sleeper-passing impacts on the axle box, bogie frame and car body. Therefore, in this study, a vertical coupled vehicle/track dynamic model was developed to investigate the sleeper-passing impacts and its effects on the dynamic performance of the high-speed train. In the model, the dynamic model of vehicle is established with 10 degrees of freedom. The track model is formulated with two rails supported on the discrete supports through the finite element method. The contact forces between the wheel and rail are estimated using the non-linear Hertz contact theory. The parametric studies are conducted to analyse effects of both the vehicle speeds and the discrete support stiffness on the sleeper-passing impacts. The results show that the sleeper-passing impacts become extremely significant with the increased support stiffness of track, especially when the frequencies of sleeper-passing impacts approach to the resonance frequencies of wheel/track system. The damping of primary suspension can effectively lower the magnitude of impacts in the resonance speed ranges, but has little effect on other speed ranges. Finally, a more comprehensively coupled vehicle/track dynamic model integrating with a flexible wheel set is developed to discuss the sleeper-passing-induced flexible vibration of wheel set.

  13. The integrated proactive surveillance system for prostate cancer.

    PubMed

    Wang, Haibin; Yatawara, Mahendra; Huang, Shao-Chi; Dudley, Kevin; Szekely, Christine; Holden, Stuart; Piantadosi, Steven

    2012-01-01

    In this paper, we present the design and implementation of the integrated proactive surveillance system for prostate cancer (PASS-PC). The integrated PASS-PC is a multi-institutional web-based system aimed at collecting a variety of data on prostate cancer patients in a standardized and efficient way. The integrated PASS-PC was commissioned by the Prostate Cancer Foundation (PCF) and built through the joint of efforts by a group of experts in medical oncology, genetics, pathology, nutrition, and cancer research informatics. Their main goal is facilitating the efficient and uniform collection of critical demographic, lifestyle, nutritional, dietary and clinical information to be used in developing new strategies in diagnosing, preventing and treating prostate cancer.The integrated PASS-PC is designed based on common industry standards - a three tiered architecture and a Service- Oriented Architecture (SOA). It utilizes open source software and programming languages such as HTML, PHP, CSS, JQuery, Drupal and MySQL. We also use a commercial database management system - Oracle 11g. The integrated PASS-PC project uses a "confederation model" that encourages participation of any interested center, irrespective of its size or location. The integrated PASS-PC utilizes a standardized approach to data collection and reporting, and uses extensive validation procedures to prevent entering erroneous data. The integrated PASS-PC controlled vocabulary is harmonized with the National Cancer Institute (NCI) Thesaurus. Currently, two cancer centers in the USA are participating in the integrated PASS-PC project.THE FINAL SYSTEM HAS THREE MAIN COMPONENTS: 1. National Prostate Surveillance Network (NPSN) website; 2. NPSN myConnect portal; 3. Proactive Surveillance System for Prostate Cancer (PASS-PC). PASS-PC is a cancer Biomedical Informatics Grid (caBIG) compatible product. The integrated PASS-PC provides a foundation for collaborative prostate cancer research. It has been built to meet the short term goal of gathering prostate cancer related data, but also with the prerequisites in place for future evolution into a cancer research informatics platform. In the future this will be vital for successful prostate cancer studies, care and treatment.

  14. The Integrated Proactive Surveillance System for Prostate Cancer

    PubMed Central

    Wang, Haibin; Yatawara, Mahendra; Huang, Shao-Chi; Dudley, Kevin; Szekely, Christine; Holden, Stuart; Piantadosi, Steven

    2012-01-01

    In this paper, we present the design and implementation of the integrated proactive surveillance system for prostate cancer (PASS-PC). The integrated PASS-PC is a multi-institutional web-based system aimed at collecting a variety of data on prostate cancer patients in a standardized and efficient way. The integrated PASS-PC was commissioned by the Prostate Cancer Foundation (PCF) and built through the joint of efforts by a group of experts in medical oncology, genetics, pathology, nutrition, and cancer research informatics. Their main goal is facilitating the efficient and uniform collection of critical demographic, lifestyle, nutritional, dietary and clinical information to be used in developing new strategies in diagnosing, preventing and treating prostate cancer. The integrated PASS-PC is designed based on common industry standards – a three tiered architecture and a Service- Oriented Architecture (SOA). It utilizes open source software and programming languages such as HTML, PHP, CSS, JQuery, Drupal and MySQL. We also use a commercial database management system – Oracle 11g. The integrated PASS-PC project uses a “confederation model” that encourages participation of any interested center, irrespective of its size or location. The integrated PASS-PC utilizes a standardized approach to data collection and reporting, and uses extensive validation procedures to prevent entering erroneous data. The integrated PASS-PC controlled vocabulary is harmonized with the National Cancer Institute (NCI) Thesaurus. Currently, two cancer centers in the USA are participating in the integrated PASS-PC project. The final system has three main components: 1. National Prostate Surveillance Network (NPSN) website; 2. NPSN myConnect portal; 3. Proactive Surveillance System for Prostate Cancer (PASS-PC). PASS-PC is a cancer Biomedical Informatics Grid (caBIG) compatible product. The integrated PASS-PC provides a foundation for collaborative prostate cancer research. It has been built to meet the short term goal of gathering prostate cancer related data, but also with the prerequisites in place for future evolution into a cancer research informatics platform. In the future this will be vital for successful prostate cancer studies, care and treatment. PMID:22505956

  15. 7 CFR 51.2285 - Tolerances for size.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... inch round hole Pass through 24/64 inch round hole Pass through 16/64 inch round hole Pass through 8/64 inch round hole Halves 5 1 (included in 5 percent) Pieces and halves 1 18 3 (included in 18 percent) 1...

  16. 7 CFR 51.2285 - Tolerances for size.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... inch round hole Pass through 24/64 inch round hole Pass through 16/64 inch round hole Pass through 8/64 inch round hole Halves 5 1 (included in 5 percent) Pieces and halves 1 18 3 (included in 18 percent) 1...

  17. Evaluating the performance and making best use of passing relief lanes.

    DOT National Transportation Integrated Search

    2011-12-01

    This report documents the evaluation of the performance and safety effectiveness of passing relief lanes within the State of Michigan. The study began with the identification of passing relief lanes within Michigan. This was followed by collecting hi...

  18. Using the arthroscopic surgery skill evaluation tool as a pass-fail examination.

    PubMed

    Koehler, Ryan J; Nicandri, Gregg T

    2013-12-04

    Examination of arthroscopic skill requires evaluation tools that are valid and reliable with clear criteria for passing. The Arthroscopic Surgery Skill Evaluation Tool was developed as a video-based assessment of technical skill with criteria for passing established by a panel of experts. The purpose of this study was to test the validity and reliability of the Arthroscopic Surgery Skill Evaluation Tool as a pass-fail examination of arthroscopic skill. Twenty-eight residents and two sports medicine faculty members were recorded performing diagnostic knee arthroscopy on a left and right cadaveric specimen in our arthroscopic skills laboratory. Procedure videos were evaluated with use of the Arthroscopic Surgery Skill Evaluation Tool by two raters blind to subject identity. Subjects were considered to pass the Arthroscopic Surgery Skill Evaluation Tool when they attained scores of ≥ 3 on all eight assessment domains. The raters agreed on a pass-fail rating for fifty-five of sixty videos rated with an interclass correlation coefficient value of 0.83. Ten of thirty participants were assigned passing scores by both raters for both diagnostic arthroscopies performed in the laboratory. Receiver operating characteristic analysis demonstrated that logging more than eighty arthroscopic cases or performing more than thirty-five arthroscopic knee cases was predictive of attaining a passing Arthroscopic Surgery Skill Evaluation Tool score on both procedures performed in the laboratory. The Arthroscopic Surgery Skill Evaluation Tool is valid and reliable as a pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. This study demonstrates that the Arthroscopic Surgery Skill Evaluation Tool may be a useful tool for pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. Further study is necessary to determine whether the Arthroscopic Surgery Skill Evaluation Tool can be used for the assessment of multiple arthroscopic procedures and whether it can be used to evaluate arthroscopic procedures performed in the operating room.

  19. SU-G-BRB-16: Vulnerabilities in the Gamma Metric

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neal, B; Siebers, J

    Purpose: To explore vulnerabilities in the gamma index metric that undermine its wide use as a radiation therapy quality assurance tool. Methods: 2D test field pairs (images) are created specifically to achieve high gamma passing rates, but to also include gross errors by exploiting the distance-to-agreement and percent-passing components of the metric. The first set has no requirement of clinical practicality, but is intended to expose vulnerabilities. The second set exposes clinically realistic vulnerabilities. To circumvent limitations inherent to user-specific tuning of prediction algorithms to match measurements, digital test cases are manually constructed, thereby mimicking high-quality image prediction. Results: Withmore » a 3 mm distance-to-agreement metric, changing field size by ±6 mm results in a gamma passing rate over 99%. For a uniform field, a lattice of passing points spaced 5 mm apart results in a passing rate of 100%. Exploiting the percent-passing component, a 10×10 cm{sup 2} field can have a 95% passing rate when an 8 cm{sup 2}=2.8×2.8 cm{sup 2} highly out-of-tolerance (e.g. zero dose) square is missing from the comparison image. For clinically realistic vulnerabilities, an arc plan for which a 2D image is created can have a >95% passing rate solely due to agreement in the lateral spillage, with the failing 5% in the critical target region. A field with an integrated boost (e.g whole brain plus small metastases) could neglect the metastases entirely, yet still pass with a 95% threshold. All the failure modes described would be visually apparent on a gamma-map image. Conclusion: The %gamma<1 metric has significant vulnerabilities. High passing rates can obscure critical faults in hypothetical and delivered radiation doses. Great caution should be used with gamma as a QA metric; users should inspect the gamma-map. Visual analysis of gamma-maps may be impractical for cine acquisition.« less

  20. Test-retest reliability and minimal detectable change of two simplified 3-point balance measures in patients with stroke.

    PubMed

    Chen, Yi-Miau; Huang, Yi-Jing; Huang, Chien-Yu; Lin, Gong-Hong; Liaw, Lih-Jiun; Lee, Shih-Chieh; Hsieh, Ching-Lin

    2017-10-01

    The 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) were simplified from the BBS and PASS to overcome the complex scoring systems. The BBS-3P and PASS-3P were more feasible in busy clinical practice and showed similarly sound validity and responsiveness to the original measures. However, the reliability of the BBS-3P and PASS-3P is unknown limiting their utility and the interpretability of scores. We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BBS-3P and PASS-3P in patients with stroke. Cross-sectional study. The rehabilitation departments of a medical center and a community hospital. A total of 51 chronic stroke patients (64.7% male). Both balance measures were administered twice 7 days apart. The test-retest reliability of both the BBS-3P and PASS-3P were examined by intraclass correlation coefficients (ICC). The MDC and its percentage over the total score (MDC%) of each measure was calculated for examining the random measurement errors. The ICC values of the BBS-3P and PASS-3P were 0.99 and 0.97, respectively. The MDC% (MDC) of the BBS-3P and PASS-3P were 9.1% (5.1 points) and 8.4% (3.0 points), respectively, indicating that both measures had small and acceptable random measurement errors. Our results showed that both the BBS-3P and the PASS-3P had good test-retest reliability, with small and acceptable random measurement error. These two simplified 3-level balance measures can provide reliable results over time. Our findings support the repeated administration of the BBS-3P and PASS-3P to monitor the balance of patients with stroke. The MDC values can help clinicians and researchers interpret the change scores more precisely.

  1. Group- and Individual-Level Responsiveness of the 3-Point Berg Balance Scale and 3-Point Postural Assessment Scale for Stroke Patients.

    PubMed

    Huang, Yi-Jing; Lin, Gong-Hong; Lee, Shih-Chieh; Chen, Yi-Miau; Huang, Sheau-Ling; Hsieh, Ching-Lin

    2018-03-01

    To examine both group- and individual-level responsiveness of the 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) in patients with stroke, and to compare the responsiveness of both 3-point measures versus their original measures (Berg Balance Scale [BBS] and Postural Assessment Scale for Stroke Patients [PASS]) and their short forms (short-form Berg Balance Scale [SFBBS] and short-form Postural Assessment Scale for Stroke Patients [SFPASS]) and between the BBS-3P and PASS-3P. Data were retrieved from a previous study wherein 212 patients were assessed at 14 and 30 days after stroke with the BBS and PASS. Medical center. Patients (N=212) with first onset of stroke within 14 days before hospitalization. Not applicable. Group-level responsiveness was examined by the standardized response mean (SRM), and individual-level responsiveness was examined by the proportion of patients whose change scores exceeded the minimal detectable change of each measure. The responsiveness was compared using the bootstrap approach. The BBS-3P and PASS-3P had good group-level (SRM, .60 and SRM, .56, respectively) and individual-level (48.1% and 44.8% of the patients with significant improvement, respectively) responsiveness. Bootstrap analyses showed that the BBS-3P generally had superior responsiveness to the BBS and SFBBS, and the PASS-3P had similar responsiveness to the PASS and SFPASS. The BBS-3P and PASS-3P were equally responsive to both group and individual change. The responsiveness of the BBS-3P and PASS-3P was comparable or superior to those of the original and short-form measures. We recommend the BBS-3P and PASS-3P as responsive outcome measures of balance for individuals with stroke. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. U-Groove Aluminum Weld Strength Improvement

    NASA Technical Reports Server (NTRS)

    Verderaime, V.; Vaughan, R.

    1997-01-01

    Though butt-welds are among the most preferred joining methods in aerostructures, their strength dependence on inelastic mechanics is generally the least understood. This study investigated experimental strain distributions across a thick aluminum U-grooved weld and identified two weld process considerations for improving the multipass weld strength. One is the source of peaking in which the extreme thermal expansion and contraction gradient of the fusion heat input across the groove tab thickness produces severe angular distortion that induces bending under uniaxial loading. The other is the filler strain hardening decreasing with increasing filler pass sequences, producing the weakest welds on the last weld pass side. Both phenomena are governed by weld pass sequences. Many industrial welding schedules unknowingly compound these effects, which reduce the weld strength. A depeaking index model was developed to select filler pass thickness, pass numbers, and sequences to improve depeaking in the welding process. The result was to select the number and sequence of weld passes to reverse the peaking angle such as to combine the strongest weld pass side with the peaking induced bending tension component side to provide a more uniform stress and stronger weld under axial tensile loading.

  3. Do Medicaid Wage Pass-through Payments Increase Nursing Home Staffing?

    PubMed Central

    Feng, Zhanlian; Lee, Yong Suk; Kuo, Sylvia; Intrator, Orna; Foster, Andrew; Mor, Vincent

    2010-01-01

    Objective To assess the impact of state Medicaid wage pass-through policy on direct-care staffing levels in U.S. nursing homes. Data Sources Online Survey Certification and Reporting (OSCAR) data, and state Medicaid nursing home reimbursement policies over the period 1996–2004. Study Design A fixed-effects panel model with two-step feasible-generalized least squares estimates is used to examine the effect of pass-through adoption on direct-care staff hours per resident day (HPRD) in nursing homes. Data Collection/Extraction Methods A panel data file tracking annual OSCAR surveys per facility over the study period is linked with annual information on state Medicaid wage pass-through and related policies. Principal Findings Among the states introducing wage pass-through over the study period, the policy is associated with between 3.0 and 4.0 percent net increases in certified nurse aide (CNA) HPRD in the years following adoption. No discernable pass-through effect is observed on either registered nurse or licensed practical nurse HPRD. Conclusions State Medicaid wage pass-through programs offer a potentially effective policy tool to boost direct-care CNA staffing in nursing homes, at least in the short term. PMID:20403054

  4. Mixing weld gases offers advantages

    NASA Technical Reports Server (NTRS)

    May, J. L.; Mendenhall, M. M.

    1969-01-01

    Argon added to helium during gas tungsten arc cover-pass welding in the horizontal position results in a better controlled wider bead width, increased arc stability, and reduction in heat input. Adequate filler material wetness and penetration pass coverage is possible with only one pass.

  5. 14. VIEW FROM TUNDRA CURVES (ON TRAIL RIDGE ROAD) SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. VIEW FROM TUNDRA CURVES (ON TRAIL RIDGE ROAD) SHOWING FALL RIVER ROAD RISING FROM BENEATH CHAPIN PASS (AT EXTREME RIGHT) TO FALL RIVER PASS (FAR LEFT). - Fall River Road, Between Estes Park & Fall River Pass, Estes Park, Larimer County, CO

  6. [Performance on the Board of Pediatrics certification examination by the Sociedad Argentina de Pediatría, 2001-2010].

    PubMed

    Ferrero, Fernando; Yulitta, Horacio; Molina, María Paz; Valli, Raúl

    2011-08-01

    Professional certification guarantees professional's performance, but the examination tool must be periodically evaluated. To describe the result of the pediatric certifying examination (PCE) of the Sociedad Argentina de Pediatría (SAP), between 2001-2010 analyzing the impact of the age and the elapsed time since the graduation and to describe the performance of training institutions in this period. Cross-section study. Data were obtained from the records of Board of Pediatrics of the SAP. The results of the PCE, were analyzed assessing examination pass rate and training institutions (2001-2010), and age and elapsed time since graduation of the examined professionals (2001-2005). Of 2527 professionals from 138 institutions, 69.6% passed. Those that passed were younger (31.7 ± 4.1 vs. 35.6 ± 6.2 years; p <0.0001) and had less years since graduation (6.3 ± 4.0 vs. 9.0 ± 5.9; p <0.0001) than those who did not pass. The examination pass rate was higher in institutions accredited by SAP (78.4% vs. 48.8%; OR= 3,8 IC95%= 3,1-4,7; p <0.001). The pass rate was significantly higher in institutions with accredited programs for 5 years than those not accredited (78.4% vs. 48.8%, OR= 3.8 95% CI= 3.1 to 4.7, p <0.001). The pass rate at accredited institutions for 3 years (53.7%) and 1 year (48.7%) showed no statistically significant differences with non-accredited institutions. The certifying examination pass rate was 68.5%. Younger professionals with fewer years since graduation, and trained in SAP 5 years accredited programs were significantly more likely to pass the examination.

  7. Expertise and decision-making in American football

    PubMed Central

    Woods, Adam J.; Kranjec, Alexander; Lehet, Matt; Chatterjee, Anjan

    2015-01-01

    In American football, pass interference calls can be difficult to make, especially when the timing of contact between players is ambiguous. American football history contains many examples of controversial pass interference decisions, often with fans, players, and officials interpreting the same event differently. The current study sought to evaluate the influence of experience with concepts important for officiating decisions in American football on the probability (i.e., response criteria) of pass interference calls. We further investigated the extent to which such experience modulates perceptual biases that might influence the interpretation of such events. We hypothesized that observers with less experience with the American football concepts important for pass interference would make progressively more pass interference calls than more experienced observers, even when given an explicit description of the necessary criteria for a pass interference call. In a go/no-go experiment using photographs from American football games, three groups of participants with different levels of experience with American football (Football Naïve, Football Player, and Football Official) made pass interference calls for pictures depicting left-moving and right-moving events. More experience was associated with progressively and significantly fewer pass interference calls [F(2,48) = 10.4, p < 0.001], with Football Naïve participants making the most pass interference calls, and Football Officials the least. In addition, our data replicated a prior finding of spatial biases for interpreting left-moving images more harshly than identical right-moving images, but only in Football Players. These data suggest that experience with the concepts important for making a decision may influence the rate of decision-making, and may also play a role in susceptibility to spatial biases. PMID:26217294

  8. Expertise and decision-making in American football.

    PubMed

    Woods, Adam J; Kranjec, Alexander; Lehet, Matt; Chatterjee, Anjan

    2015-01-01

    In American football, pass interference calls can be difficult to make, especially when the timing of contact between players is ambiguous. American football history contains many examples of controversial pass interference decisions, often with fans, players, and officials interpreting the same event differently. The current study sought to evaluate the influence of experience with concepts important for officiating decisions in American football on the probability (i.e., response criteria) of pass interference calls. We further investigated the extent to which such experience modulates perceptual biases that might influence the interpretation of such events. We hypothesized that observers with less experience with the American football concepts important for pass interference would make progressively more pass interference calls than more experienced observers, even when given an explicit description of the necessary criteria for a pass interference call. In a go/no-go experiment using photographs from American football games, three groups of participants with different levels of experience with American football (Football Naïve, Football Player, and Football Official) made pass interference calls for pictures depicting left-moving and right-moving events. More experience was associated with progressively and significantly fewer pass interference calls [F (2,48) = 10.4, p < 0.001], with Football Naïve participants making the most pass interference calls, and Football Officials the least. In addition, our data replicated a prior finding of spatial biases for interpreting left-moving images more harshly than identical right-moving images, but only in Football Players. These data suggest that experience with the concepts important for making a decision may influence the rate of decision-making, and may also play a role in susceptibility to spatial biases.

  9. Relationship between internal medicine program board examination pass rates, accreditation standards, and program size.

    PubMed

    Falcone, John L; Gonzalo, Jed D

    2014-01-19

    To determine Internal Medicine residency program compliance with the Accreditation Council for Graduate Medical Education 80% pass-rate standard and the correlation between residency program size and performance on the American Board of Internal Medicine Certifying Examination. Using a cross-sectional study design from 2010-2012 American Board of Internal Medicine Certifying Examination data of all Internal Medicine residency pro-grams, comparisons were made between program pass rates to the Accreditation Council for Graduate Medical Education pass-rate standard. To assess the correlation between program size and performance, a Spearman's rho was calculated. To evaluate program size and its relationship to the pass-rate standard, receiver operative characteristic curves were calculated. Of 372 Internal Medicine residency programs, 276 programs (74%) achieved a pass rate of =80%, surpassing the Accreditation Council for Graduate Medical Education minimum standard. A weak correlation was found between residency program size and pass rate for the three-year period (p=0.19, p<0.001). The area underneath the receiver operative characteristic curve was 0.69 (95% Confidence Interval [0.63-0.75]), suggesting programs with less than 12 examinees/year are less likely to meet the minimum Accreditation Council for Graduate Medical Education pass-rate standard (sensitivity 63.8%, specificity 60.4%, positive predictive value 82.2%, p<0.001). Although a majority of Internal Medicine residency programs complied with Accreditation Council for Graduate Medical Education pass-rate standards, a quarter of the programs failed to meet this requirement. Program size is positively but weakly associated with American Board of Internal Medicine Certifying Examination performance, suggesting other unidentified variables significantly contribute to program performance.

  10. Pulsed dye laser double-pass treatment of patients with resistant capillary malformations.

    PubMed

    Rajaratnam, Ratna; Laughlin, Sharyn A; Dudley, Denis

    2011-07-01

    The pulsed dye laser is an effective and established treatment for port-wine stains and has become the generally accepted standard of care. However, in many cases, complete clearance cannot be achieved as a significant proportion of lesions become resistant to treatment. Multiple passes or pulse-stacking techniques have been used to improve the extent and rate of fading, but concerns over increased adverse effects have limited this clinical approach. In this work, a double-pass technique with the pulsed dye laser has been described, which may allow for increased depth of vascular injury, greater efficacy, and an acceptable risk profile. Our aim was to determine the efficacy and the rate of side-effects for a double-pass protocol with a pulsed dye laser (PDL) to treat patients previously treated with PDL and/or other laser modalities. A retrospective chart review was conducted of 26 patients treated with a minimum of three double-pass treatments alone, or in combination, with single pass conventional PDL. Almost half of the patients (n = 12) showed either a moderate or significant improvement in fading compared to pre-treatment photographs with the double-pass technique. In a further 12 patients, there was a mild improvement. In two patients, there was no change. Sixteen patients developed mild side-effects: blisters (n = 5), dry scabs (n = 11) and transient hyperpigmentation (n = 4). This preliminary experience suggests that a double-pass technique at defined intervals between the first and second treatment with PDL can further lighten some port-wine stains, which are resistant to conventional single-pass treatments. This technique may be a useful addition to the laser treatment of PWS and deserves further scrutiny with randomized prospective studies and histological analysis to confirm the increased depth of vascular injury.

  11. Langevin and Fokker-Planck analyses of inhibited molecular passing processes controlling transport and reactivity in nanoporous materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chi-Jen; Ackerman, David M.; Slowing, Igor I.

    2014-07-14

    Inhibited passing of reactant and product molecules within the linear pores of nanoporous catalytic materials strongly reduces reactivity. The dependence of the passing propensity P on pore radius R is analyzed utilizing Langevin dynamics to account for solvent effects. We find that P~(R-R c) σ, where passing is sterically blocked for R≤R c, with σ below the transition state theory value. Deeper insight comes from analysis of the corresponding high-dimensional Fokker-Planck equation, which facilitates an effective small-P approximation, and dimensional reduction enabling utilization of conformal mapping ideas. We analyze passing for spherical molecules and also assess the effect of rotationalmore » degrees of freedom for elongated molecules.« less

  12. Teaching Strategies for the Forearm Pass in Volleyball

    ERIC Educational Resources Information Center

    Casebolt, Kevin; Zhang, Peng; Brett, Christine

    2014-01-01

    This article shares teaching strategies for the forearm pass in the game of volleyball and identifies how they will help students improve their performance and development of forearm passing skills. The article also provides an assessment rubric to facilitate student understanding of the skill.

  13. 48 CFR 652.237-71 - Identification/Building Pass.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Identification/Building... Identification/Building Pass. As prescribed in 637.110(b), insert the following clause. Identification/Building.... (1) The contractor shall obtain a Department of State building pass for all employees performing...

  14. The aerodynamic effects of passing trains to surrounding objects and people

    DOT National Transportation Integrated Search

    2009-04-01

    Two safety issues are raised on the aerodynamic effects of a passing train on its surroundings. First, a high-speed train passing other trains on an adjacent track exerts aerodynamic pressure that can affect the structural integrity of window mount a...

  15. 47 CFR 6.9 - Information pass through.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... achievable. In particular, signal compression technologies shall not remove information needed for access or... 47 Telecommunication 1 2010-10-01 2010-10-01 false Information pass through. 6.9 Section 6.9... Entities Do? § 6.9 Information pass through. Telecommunications equipment and customer premises equipment...

  16. Energy savings from transit passes : an evaluation of the University at Buffalo NFTA transit pass program for students, faculty, and staff.

    DOT National Transportation Integrated Search

    2014-04-01

    The University Transportation Research Center Region 2 supported a study entitled Connections Beyond Campus: An Evaluation of the Niagara Frontier Transportation : Authority University at Buffalo Transit Pass Program. Unlimited Access t...

  17. Development of polarization-controlled multi-pass Thomson scattering system in the GAMMA 10 tandem mirror

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshikawa, M.; Morimoto, M.; Shima, Y.

    2012-10-15

    In the GAMMA 10 tandem mirror, the typical electron density is comparable to that of the peripheral plasma of torus-type fusion devices. Therefore, an effective method to increase Thomson scattering (TS) signals is required in order to improve signal quality. In GAMMA 10, the yttrium-aluminum-garnet (YAG)-TS system comprises a laser, incident optics, light collection optics, signal detection electronics, and a data recording system. We have been developing a multi-pass TS method for a polarization-based system based on the GAMMA 10 YAG TS. To evaluate the effectiveness of the polarization-based configuration, the multi-pass system was installed in the GAMMA 10 YAG-TSmore » system, which is capable of double-pass scattering. We carried out a Rayleigh scattering experiment and applied this double-pass scattering system to the GAMMA 10 plasma. The integrated scattering signal was made about twice as large by the double-pass system.« less

  18. Ductility Improvement of an AZ61 Magnesium Alloy through Two-Pass Submerged Friction Stir Processing

    PubMed Central

    Luo, Xicai; Cao, Genghua; Zhang, Wen; Qiu, Cheng; Zhang, Datong

    2017-01-01

    Friction stir processing (FSP) has been considered as a novel technique to refine the grain size and homogenize the microstructure of metallic materials. In this study, two-pass FSP was conducted under water to enhance the cooling rate during processing, and an AZ61 magnesium alloy with fine-grained and homogeneous microstructure was prepared through this method. Compared to the as-cast material, one-pass FSP resulted in grain refinement and the β-Mg17Al12 phase was broken into small particles. Using a smaller stirring tool and an overlapping ratio of 100%, a finer and more uniform microstructure with an average grain size of 4.6 μm was obtained through two-pass FSP. The two-pass FSP resulted in a significant improvement in elongation of 37.2% ± 4.3%, but a slight decrease in strength compared with one-pass FSP alloy. Besides the microstructure refinement, the texture evolution in the stir zone is also considered responsible for the ductility improvement. PMID:28772614

  19. Effects of hot compression deformation temperature on the microstructure and properties of Al-Zr-La alloys

    NASA Astrophysics Data System (ADS)

    Yue, Xian-hua; Liu, Chun-fang; Liu, Hui-hua; Xiao, Su-fen; Tang, Zheng-hua; Tang, Tian

    2018-02-01

    The main goal of this study is to investigate the microstructure and electrical properties of Al-Zr-La alloys under different hot compression deformation temperatures. In particular, a Gleeble 3500 thermal simulator was used to carry out multi-pass hot compression tests. For five-pass hot compression deformation, the last-pass deformation temperatures were 240, 260, 300, 340, 380, and 420°C, respectively, where the first-pass deformation temperature was 460°C. The experimental results indicated that increasing the hot compression deformation temperature with each pass resulted in improved electrical conductivity of the alloy. Consequently, the flow stress was reduced after deformation of the samples subjected to the same number of passes. In addition, the dislocation density gradually decreased and the grain size increased after hot compression deformation. Furthermore, the dynamic recrystallization behavior was effectively suppressed during the hot compression process because spherical Al3Zr precipitates pinned the dislocation movement effectively and prevented grain boundary sliding.

  20. Multiple-pass high-pressure homogenization of milk for the development of pasteurization-like processing conditions.

    PubMed

    Ruiz-Espinosa, H; Amador-Espejo, G G; Barcenas-Pozos, M E; Angulo-Guerrero, J O; Garcia, H S; Welti-Chanes, J

    2013-02-01

    Multiple-pass ultrahigh pressure homogenization (UHPH) was used for reducing microbial population of both indigenous spoilage microflora in whole raw milk and a baroresistant pathogen (Staphylococcus aureus) inoculated in whole sterile milk to define pasteurization-like processing conditions. Response surface methodology was followed and multiple response optimization of UHPH operating pressure (OP) (100, 175, 250 MPa) and number of passes (N) (1-5) was conducted through overlaid contour plot analysis. Increasing OP and N had a significant effect (P < 0·05) on microbial reduction of both spoilage microflora and Staph. aureus in milk. Optimized UHPH processes (five 202-MPa passes; four 232-MPa passes) defined a region where a 5-log(10) reduction of total bacterial count of milk and a baroresistant pathogen are attainable, as a requisite parameter for establishing an alternative method of pasteurization. Multiple-pass UHPH optimized conditions might help in producing safe milk without the detrimental effects associated with thermal pasteurization. © 2012 The Society for Applied Microbiology.

  1. The role of low-spatial frequencies in lexical decision and masked priming.

    PubMed

    Boden, C; Giaschi, D

    2009-04-01

    Spatial frequency filtering was used to test the hypotheses that low-spatial frequency information in printed text can: (1) lead to a rapid lexical decision or (2) facilitate word recognition. Adult proficient readers made lexical decisions in unprimed and masked repetition priming experiments with unfiltered, low-pass, high-pass and notch filtered letter strings. In the unprimed experiments, a filtered target was presented for 105 or 400 ms followed by a pattern mask. Sensitivity (d') was lowest for the low-pass filtered targets at both durations with a bias towards a 'non-word' response. Sensitivity was higher in the high-pass and notch filter conditions. In the priming experiments, a forward mask was followed by a filtered prime then an unfiltered target. Primed words, but not non-words, were identified faster than unprimed words in both the low-pass and high-pass filtered conditions. These results do not support a unique role for low-spatial frequency information in either facilitating or making rapid lexical decisions.

  2. The reliability of the pass/fail decision for assessments comprised of multiple components.

    PubMed

    Möltner, Andreas; Tımbıl, Sevgi; Jünger, Jana

    2015-01-01

    The decision having the most serious consequences for a student taking an assessment is the one to pass or fail that student. For this reason, the reliability of the pass/fail decision must be determined for high quality assessments, just as the measurement reliability of the point values. Assessments in a particular subject (graded course credit) are often composed of multiple components that must be passed independently of each other. When "conjunctively" combining separate pass/fail decisions, as with other complex decision rules for passing, adequate methods of analysis are necessary for estimating the accuracy and consistency of these classifications. To date, very few papers have addressed this issue; a generally applicable procedure was published by Douglas and Mislevy in 2010. Using the example of an assessment comprised of several parts that must be passed separately, this study analyzes the reliability underlying the decision to pass or fail students and discusses the impact of an improved method for identifying those who do not fulfill the minimum requirements. The accuracy and consistency of the decision to pass or fail an examinee in the subject cluster Internal Medicine/General Medicine/Clinical Chemistry at the University of Heidelberg's Faculty of Medicine was investigated. This cluster requires students to separately pass three components (two written exams and an OSCE), whereby students may reattempt to pass each component twice. Our analysis was carried out using the method described by Douglas and Mislevy. Frequently, when complex logical connections exist between the individual pass/fail decisions in the case of low failure rates, only a very low reliability for the overall decision to grant graded course credit can be achieved, even if high reliabilities exist for the various components. For the example analyzed here, the classification accuracy and consistency when conjunctively combining the three individual parts is relatively low with κ=0.49 or κ=0.47, despite the good reliability of over 0.75 for each of the three components. The option to repeat each component twice leads to a situation in which only about half of the candidates who do not satisfy the minimum requirements would fail the overall assessment, while the other half is able to continue their studies despite having deficient knowledge and skills. The method put forth by Douglas and Mislevy allows the analysis of the decision accuracy and consistency for complex combinations of scores from different components. Even in the case of highly reliable components, it is not necessarily so that a reliable pass/fail decision has been reached - for instance in the case of low failure rates. Assessments must be administered with the explicit goal of identifying examinees that do not fulfill the minimum requirements.

  3. The reliability of the pass/fail decision for assessments comprised of multiple components

    PubMed Central

    Möltner, Andreas; Tımbıl, Sevgi; Jünger, Jana

    2015-01-01

    Objective: The decision having the most serious consequences for a student taking an assessment is the one to pass or fail that student. For this reason, the reliability of the pass/fail decision must be determined for high quality assessments, just as the measurement reliability of the point values. Assessments in a particular subject (graded course credit) are often composed of multiple components that must be passed independently of each other. When “conjunctively” combining separate pass/fail decisions, as with other complex decision rules for passing, adequate methods of analysis are necessary for estimating the accuracy and consistency of these classifications. To date, very few papers have addressed this issue; a generally applicable procedure was published by Douglas and Mislevy in 2010. Using the example of an assessment comprised of several parts that must be passed separately, this study analyzes the reliability underlying the decision to pass or fail students and discusses the impact of an improved method for identifying those who do not fulfill the minimum requirements. Method: The accuracy and consistency of the decision to pass or fail an examinee in the subject cluster Internal Medicine/General Medicine/Clinical Chemistry at the University of Heidelberg’s Faculty of Medicine was investigated. This cluster requires students to separately pass three components (two written exams and an OSCE), whereby students may reattempt to pass each component twice. Our analysis was carried out using the method described by Douglas and Mislevy. Results: Frequently, when complex logical connections exist between the individual pass/fail decisions in the case of low failure rates, only a very low reliability for the overall decision to grant graded course credit can be achieved, even if high reliabilities exist for the various components. For the example analyzed here, the classification accuracy and consistency when conjunctively combining the three individual parts is relatively low with κ=0.49 or κ=0.47, despite the good reliability of over 0.75 for each of the three components. The option to repeat each component twice leads to a situation in which only about half of the candidates who do not satisfy the minimum requirements would fail the overall assessment, while the other half is able to continue their studies despite having deficient knowledge and skills. Conclusion: The method put forth by Douglas and Mislevy allows the analysis of the decision accuracy and consistency for complex combinations of scores from different components. Even in the case of highly reliable components, it is not necessarily so that a reliable pass/fail decision has been reached – for instance in the case of low failure rates. Assessments must be administered with the explicit goal of identifying examinees that do not fulfill the minimum requirements. PMID:26483855

  4. Pass-fail grading: laying the foundation for self-regulated learning.

    PubMed

    White, Casey B; Fantone, Joseph C

    2010-10-01

    Traditionally, medical schools have tended to make assumptions that students will "automatically" engage in self-education effectively after graduation and subsequent training in residency and fellowships. In reality, the majority of medical graduates out in practice feel unprepared for learning on their own. Many medical schools are now adopting strategies and pedagogies to help students become self-regulating learners. Along with these changes in practices and pedagogy, many schools are eliminating a cornerstone of extrinsic motivation: discriminating grades. To study the effects of the switch from discriminating to pass-fail grading in the second year of medical school, we compared internal and external assessments and evaluations for a second-year class with a discriminating grading scale (Honors, High Pass, Pass, Fail) and for a second-year class with a pass-fail grading scale. Of the measures we compared (MCATs, GPAs, means on second-year examinations, USMLE Step 1 scores, residency placement, in which there were no statistically significant changes), the only statistically significant decreases (lower performance with pass fail) were found in two of the second-year courses. Performance in one other course also improved significantly. Pass-fail grading can meet several important intended outcomes, including "leveling the playing field" for incoming students with different academic backgrounds, reducing competition and fostering collaboration among members of a class, more time for extracurricular interests and personal activities. Pass-fail grading also reduces competition and supports collaboration, and fosters intrinsic motivation, which is key to self-regulated, lifelong learning.

  5. Nursing students' attendance at learning activities in relation to attainment and passing courses: A prospective quantitative study.

    PubMed

    Rejnö, Åsa; Nordin, Per; Forsgren, Susanne; Sundell, Yvonne; Rudolfsson, Gudrun

    2017-03-01

    Students' motivation and ways of engaging in their schoolwork are important for their performance, including passing exams. Attendance at learning activities has also been argued to be of major importance, although no causal relationship with passing exams has been established in nursing education. The aim of this study was to describe the impact of attendance at nonmandatory learning activities on attainment, in terms of passing or failing of exams, in nursing education courses including both mandatory and non-mandatory activities. A prospective quantitative design. The nursing education programme at a Swedish university. Nursing students (n=361) from two courses and four classes within the nursing programme. Attendance was registered at every non-mandatory teaching activity by asking the students to note their attendance on a list. Data such as sex, age, and whether the students had passed the exam were also collected for each course and each semester separately. Increased participation was associated with an increasing proportion of students passing the exam. The chance of passing the exam increased by 13% for every additional learning occasion attended. Logistic regression showed an OR of 5.4 for an attendance of 100%. An increase in attendance gave a higher proportion of exam passes. Encouraging students to attend non-mandatory learning activities could be of value, and potentially contribute to an increased graduation rate for nursing students. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. 47 CFR 73.9006 - Add-in covered demodulator products.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Section 73.9006 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES... passed to an output (e.g., where a demodulator add-in card in a personal computer passes such content to an associated software application installed in the same computer), it shall pass such content: (1...

  7. PASS--Placement/Advisement for Student Success.

    ERIC Educational Resources Information Center

    Shreve, Chuck; Wildie, Avace

    In 1985-86, Northern Michigan College (NMC) used funds received from the United States Department of Education to develop a system of assessment, advisement, and placement--Placement/Advisement for Student Success (PASS), an integrated system designed to improve student retention. PASS currently consists of three components: summer orientation,…

  8. ACHP | News | Legislation Passes Senate

    Science.gov Websites

    Search skip specific nav links Home arrow News arrow Legislation Passes Senate Secretary Kempthorne continue historic preservation programs founded by each of the past two First Ladies in legislation passed Hillary Clinton. "Bipartisan approval of this legislation by an overwhelming margin reflects the

  9. 47 CFR 7.9 - Information pass through.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Information pass through. 7.9 Section 7.9 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL ACCESS TO VOICEMAIL AND INTERACTIVE MENU SERVICES AND EQUIPMENT BY PEOPLE WITH DISABILITIES Obligations-What Must Covered Entities Do? § 7.9 Information pass...

  10. 47 CFR 7.9 - Information pass through.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Information pass through. 7.9 Section 7.9 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL ACCESS TO VOICEMAIL AND INTERACTIVE MENU SERVICES AND EQUIPMENT BY PEOPLE WITH DISABILITIES Obligations-What Must Covered Entities Do? § 7.9 Information pass...

  11. 47 CFR 7.9 - Information pass through.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Information pass through. 7.9 Section 7.9 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL ACCESS TO VOICEMAIL AND INTERACTIVE MENU SERVICES AND EQUIPMENT BY PEOPLE WITH DISABILITIES Obligations-What Must Covered Entities Do? § 7.9 Information pass...

  12. 47 CFR 7.9 - Information pass through.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Information pass through. 7.9 Section 7.9 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL ACCESS TO VOICEMAIL AND INTERACTIVE MENU SERVICES AND EQUIPMENT BY PEOPLE WITH DISABILITIES Obligations-What Must Covered Entities Do? § 7.9 Information pass...

  13. Evolving Trends in the Epidemiology, Resource Utilization, and Outcomes of Pregnancy-Associated Severe Sepsis: A Population-Based Cohort Study

    PubMed Central

    Oud, Lavi; Watkins, Phillip

    2015-01-01

    Background Infections are a well-known complication of pregnancy. However, pregnancy-associated severe sepsis (PASS) has not been as well-characterized, with limited population-level data reported to date. We performed a population-based study of the evolving patterns of the epidemiology, clinical characteristics, resource utilization, and outcomes of PASS in Texas over the past decade. Methods The Texas Inpatient Public Use Data File was used to identify pregnancy-associated hospitalizations and PASS hospitalizations for the years 2001 - 2010. The Texas Center for Health Statistics reports of live births, abortions and fetal deaths, and a previously reported population-based, age-specific linkage study on miscarriage were used to derive the annual total estimated pregnancies (TEPs). The incidence, demographics, clinical characteristics, resource utilization and outcomes of PASS were examined. Logistic regression modeling was used to explore the predictors of PASS and its associated mortality. Results There were 4,060,201 pregnancy-associated hospitalizations and 1,007 PASS hospitalizations during study period. The incidence of PASS was increased by 236% over the past decade, rising from 11 to 26 hospitalizations per 100,000 TEPs. The key changes between 2001 - 2002 and 2009 - 2010 within PASS hospitalizations included: admission to ICU 78% vs. 90% (P = 0.002); development of ≥ 3 organ failures 9% vs. 35% (P < 0.0001); and inflation-adjusted median hospital charges (2,010 dollars) $64,034 vs. $89,895 (P = 0.0141). Hospital mortality (11%) remained unchanged during study period. Chronic liver disease (adjusted odds ratio (aOR) 41.4) and congestive heart failure (CHF) (aOR 20.5) were associated with the highest risk of PASS, in addition to black race, poverty, drug abuse, and lack of health insurance. The highest risk of death was among women with HIV infection (aOR 45.5), need for mechanical ventilation (aOR 4.5), drug abuse (aOR 3.0), and lacking health insurance (aOR 2.9). Conclusions The incidence, severity, and fiscal burden of PASS rose substantially over the past decade. Case fatality was lower than that for severe sepsis in the general population. Chronic liver disease and CHF pose especially high risk of PASS. Pregnant women with history of drug abuse and lacking health insurance are at high risk of both developing and dying with PASS, requiring extra vigilance for early diagnosis and targeted intervention. PMID:25883702

  14. 48 CFR 2415.304 - Evaluation factors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DEVELOPMENT CONTRACTING METHODS AND CONTRACTING TYPES CONTRACTING BY NEGOTIATION Source Selection 2415.304... assigned a numerical weight (except for pass-fail factors) which shall appear in the RFP. When using LPTA, each evaluation factor is applied on a “pass-fail” basis; numerical scores are not assigned. “Pass-fail...

  15. 49 CFR 172.102 - Special provisions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... design type that has passed a leakproofness test at the Packing Group II level. Small inner packagings... packaging or transport unit is closed. Each packaging must correspond to a design type that has passed a... transport unit is closed. Each packaging must correspond to a design type that has passed a leakproofness...

  16. 49 CFR 172.102 - Special provisions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... bags, each packaging must correspond to a design type that has passed a leakproofness test at the... packaging must correspond to a design type that has passed a leakproofness test at the Packing Group II... packaging must correspond to a design type that has passed a leakproofness test at the Packing Group II...

  17. 49 CFR 172.102 - Special provisions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... packaging must correspond to a design type that has passed a leakproofness test at the Packing Group II... packaging must correspond to a design type that has passed a leakproofness test at the Packing Group II... packagings, each packaging must correspond to a design type that has passed a leakproofness test at the...

  18. 49 CFR 172.102 - Special provisions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... packaging must correspond to a design type that has passed a leakproofness test at the Packing Group II... packaging must correspond to a design type that has passed a leakproofness test at the Packing Group II... packagings, each packaging must correspond to a design type that has passed a leakproofness test at the...

  19. 49 CFR 172.102 - Special provisions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... design type that has passed a leakproofness test at the Packing Group II level. Small inner packagings... packaging or transport unit is closed. Each packaging must correspond to a design type that has passed a... transport unit is closed. Each packaging must correspond to a design type that has passed a leakproofness...

  20. 12 CFR 560.32 - Pass-through investments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Pass-through investments. 560.32 Section 560.32 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY LENDING AND INVESTMENT Lending and Investment Powers for Federal Savings Associations § 560.32 Pass-through investments. (a) A...

  1. Low-Noise Band-Pass Amplifier

    NASA Technical Reports Server (NTRS)

    Kleinberg, L.

    1982-01-01

    Circuit uses standard components to overcome common limitation of JFET amplifiers. Low-noise band-pass amplifier employs JFET and operational amplifier. High gain and band-pass characteristics are achieved with suitable choice of resistances and capacitances. Circuit should find use as low-noise amplifier, for example as first stage instrumentation systems.

  2. 42 CFR 419.64 - Transitional pass-through payments: Drugs and biologicals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... biologicals. 419.64 Section 419.64 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... biologicals. (a) Eligibility for pass-through payment. CMS makes a transitional pass-through payment for the following drugs and biologicals that are furnished as part of an outpatient hospital service: (1) Orphan...

  3. 42 CFR 419.64 - Transitional pass-through payments: Drugs and biologicals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... biologicals. 419.64 Section 419.64 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... biologicals. (a) Eligibility for pass-through payment. CMS makes a transitional pass-through payment for the following drugs and biologicals that are furnished as part of an outpatient hospital service: (1) Orphan...

  4. 12 CFR 560.32 - Pass-through investments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 5 2011-01-01 2011-01-01 false Pass-through investments. 560.32 Section 560.32 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY LENDING AND INVESTMENT Lending and Investment Powers for Federal Savings Associations § 560.32 Pass-through investments. (a) A...

  5. 26 CFR 1.1295-3 - Retroactive elections.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... termination of a pass through entity or pass through entity's business. The complete termination of a pass...'s trade or business, will not terminate a waiver that applies to a partner, shareholder, or... entity or the entity's trade or business. (ii) Terms of waiver—(A) Scope of waiver. The waiver of the...

  6. Establishing Passing Scores.

    ERIC Educational Resources Information Center

    McLarty, Joyce R.

    The problem of establishing appropriate passing scores is one of evaluation rather than estimation and not amenable to exact solution. It must therefore be approached by (1) identifying criteria for judging the acceptability of the passing score, (2) collecting the data appropriate to assessing each relevant criterion, and (3) judging how well the…

  7. 77 FR 56686 - Self-Regulatory Organizations; Financial Industry Regulatory Authority, Inc.; Notice of Filing of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-13

    ... Change Relating to Post-Trade Transparency for Agency Pass-Through Mortgage-Backed Securities Traded in... and dissemination of transactions in TRACE- Eligible Securities that are: (1) Agency Pass-Through... Security, Agency Pass-Through Mortgage-Backed Security, Specified Pool Transaction, Asset-Backed Security...

  8. 78 FR 62728 - Self Regulatory Organizations; Chicago Stock Exchange, Inc.; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... registered as Institutional Brokers will be required to pass the appropriate examinations as defined in the... pass the Exchange's internal Institutional Broker Examination.\\10\\ The proposed rules clarify that Institutional Broker Representatives will need to pass the internal Institutional Broker Examination as under...

  9. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... invalid test condition, unsafe conditions, fast pass/fail algorithms, or, in the case of the on-board... using approved fast pass or fast fail algorithms and multiple pass/fail algorithms may be used during the test cycle to eliminate false failures. The transient test procedure, including algorithms and...

  10. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... invalid test condition, unsafe conditions, fast pass/fail algorithms, or, in the case of the on-board... using approved fast pass or fast fail algorithms and multiple pass/fail algorithms may be used during the test cycle to eliminate false failures. The transient test procedure, including algorithms and...

  11. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... invalid test condition, unsafe conditions, fast pass/fail algorithms, or, in the case of the on-board... using approved fast pass or fast fail algorithms and multiple pass/fail algorithms may be used during the test cycle to eliminate false failures. The transient test procedure, including algorithms and...

  12. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... invalid test condition, unsafe conditions, fast pass/fail algorithms, or, in the case of the on-board... using approved fast pass or fast fail algorithms and multiple pass/fail algorithms may be used during the test cycle to eliminate false failures. The transient test procedure, including algorithms and...

  13. North elevation from shoulder of Altamont Pass Road; Interstate Highway ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    North elevation from shoulder of Altamont Pass Road; Interstate Highway 5 viaduct in background; former Western Pacific (now Union Pacific) Railroad at right; abandoned Southern Pacific right of way beneath bridge; view to southwest; 90 mm lens - Carroll Overhead Bridge, Altamont Pass Road, Livermore, Alameda County, CA

  14. 14 CFR 61.35 - Knowledge test: Prerequisites and passing grades.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Knowledge test: Prerequisites and passing....35 Knowledge test: Prerequisites and passing grades. (a) An applicant for a knowledge test must have... the applicant accomplished the appropriate ground-training or a home-study course required by this...

  15. 14 CFR 61.35 - Knowledge test: Prerequisites and passing grades.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Knowledge test: Prerequisites and passing....35 Knowledge test: Prerequisites and passing grades. (a) An applicant for a knowledge test must have... the applicant accomplished the appropriate ground-training or a home-study course required by this...

  16. Efficient Single-Pass Index Construction for Text Databases.

    ERIC Educational Resources Information Center

    Heinz, Steffen; Zobel, Justin

    2003-01-01

    Discusses index construction for text collections, reviews principal approaches to inverted indexes, analyzes their theoretical cost, and presents experimental results of the use of a single-pass inversion method on Web document collections. Shows that the single-pass approach is faster and does not require the complete vocabulary of the indexed…

  17. 20 CFR 631.18 - Federal by-pass authority.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Federal by-pass authority. 631.18 Section 631.18 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR PROGRAMS UNDER... Secretary's intent to exercise by-pass authority and an opportunity to request and to receive a hearing...

  18. 9 CFR 311.18 - Caseous lymphadenitis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...-marked lesions in the skeletal lymph nodes with only slight lesions elsewhere may be passed for cooking... may be passed for cooking; but where the lesions in a well-nourished carcass are both numerous and... without restriction or passed for cooking shall be removed and condemned. (g) As used in this section, the...

  19. Finding Your Way in the Legislation Maze: How To Pass Legislation in Your State.

    ERIC Educational Resources Information Center

    Gross, Steve

    1997-01-01

    Offers tips for developing and passing legislation that would protect animals. Recommends being an authority on the issue, researching current laws, recognizing support groups and lobbyists, and knowing key legislative players. Contains a description of laws passed in the state of Illinois. (PVD)

  20. On sampling band-pass signals

    NASA Technical Reports Server (NTRS)

    Sadr, R.; Shahshahani, M.

    1989-01-01

    Four techniques for uniform sampling of band-bass signals are examined. The in-phase and quadrature components of the band-pass signal are computed in terms of the samples of the original band-pass signal. The relative implementation merits of these techniques are discussed with reference to the Deep Space Network (DSN).

  1. Using Silence to "Pass": Embodiment and Interactional Categorization in a Diasporic Context

    ERIC Educational Resources Information Center

    Wagner, Lauren

    2015-01-01

    This article posits that "passing" is a manipulation of ambiguously embodied characteristics, linguistic practice, and ratification by other speakers. I explore discourses and practices of "passing" by post-migrant generation, diasporically-resident Moroccans who seek to be unmarked by migration when bargaining in Moroccan…

  2. Baseline wildlife monitoring at I-90 Snoqualmie Pass East, prior to the installation of wildlife crossing structures.

    DOT National Transportation Integrated Search

    2012-12-01

    The I-90 Snoqualmie Pass East Project (SPE) is located along a 15-mile stretch of Interstate 90 : that passes through the Okanogan-Wenatchee National Forest. The project corridor has been : identified as a critical connectivity zone for Pacific North...

  3. 42 CFR 419.64 - Transitional pass-through payments: Drugs and biologicals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., 2000. (2) Cancer therapy drugs and biologicals. A drug or biological that is used in cancer therapy... 42 Public Health 3 2014-10-01 2014-10-01 false Transitional pass-through payments: Drugs and...-through payments: Drugs and biologicals. (a) Eligibility for pass-through payment. CMS makes a...

  4. 42 CFR 419.64 - Transitional pass-through payments: Drugs and biologicals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., 2000. (2) Cancer therapy drugs and biologicals. A drug or biological that is used in cancer therapy... 42 Public Health 3 2012-10-01 2012-10-01 false Transitional pass-through payments: Drugs and...-through payments: Drugs and biologicals. (a) Eligibility for pass-through payment. CMS makes a...

  5. 42 CFR 419.64 - Transitional pass-through payments: Drugs and biologicals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., 2000. (2) Cancer therapy drugs and biologicals. A drug or biological that is used in cancer therapy... 42 Public Health 3 2013-10-01 2013-10-01 false Transitional pass-through payments: Drugs and...-through payments: Drugs and biologicals. (a) Eligibility for pass-through payment. CMS makes a...

  6. AVHRR Satellite Data - Users Guide for Accessing NOARL Archives

    DTIC Science & Technology

    1991-08-01

    passes recorded from NOAA-9, NOAA- 10 and NOAA- I I polar orbiters. Data is in the form of raw radiance counts in 1 km by 1 km bins in 5 separate...wavelength channels ranging from visible to infrared (IR) (see Table 1). For each recorded pass, the collected data covers a finite section of the globe. An...while the number of recorded lines along the length of the orbiter’s path varies from pass to pass. Typically, from 8 to 15 minutes of data are stored

  7. Feasibility Study to Adapt the Microflown Vector Sensor for Underwater Use

    DTIC Science & Technology

    2012-12-01

    properties were of less importance for this experiment. A calibrated ACO Pacific pressure microphone in combination with an ACO pacific 1/2” preamplifier ... preamplifier was used for amplification and filtering. Pre-amplification was set to 10x and a 1 kHz High pass and 100 kHz Low pass filter was used to reduce...Kjær Turntable system type 9640 Stanford RS preamplifier model SR560 Pre-amplification: 10x High pass filter: 1 kHz Low pass filter: 100 kHz

  8. Does administering a comprehensive examination affect pass rates on the Registered Health Information Administrator certification examination?

    PubMed

    McNeill, Marjorie H

    2009-01-01

    The purpose of this research study was to determine whether the administration of a comprehensive examination before graduation increases the percentage of students passing the Registered Health Information Administrator certification examination. A t-test for independent means yielded a statistically significant difference between the Registered Health Information Administrator certification examination pass rates of health information administration programs that administer a comprehensive examination and programs that do not administer a comprehensive examination. Programs with a high certification examination pass rate do not require a comprehensive examination when compared with those programs with a lower pass rate. It is concluded that health information administration faculty at the local level should perform program self-analysis to improve student progress toward achievement of learning outcomes and entry-level competencies.

  9. Hydrogen production by high temperature water splitting using electron conducting membranes

    DOEpatents

    Balachandran, Uthamalingam; Wang, Shuangyan; Dorris, Stephen E.; Lee, Tae H.

    2006-08-08

    A device and method for separating water into hydrogen and oxygen is disclosed. A first substantially gas impervious solid electron-conducting membrane for selectively passing protons or hydrogen is provided and spaced from a second substantially gas impervious solid electron-conducting membrane for selectively passing oxygen. When steam is passed between the two membranes at dissociation temperatures the hydrogen from the dissociation of steam selectively and continuously passes through the first membrane and oxygen selectively and continuously passes through the second membrane, thereby continuously driving the dissociation of steam producing hydrogen and oxygen. The oxygen is thereafter reacted with methane to produce syngas which optimally may be reacted in a water gas shift reaction to produce CO2 and H2.

  10. High time resolved electron temperature measurements by using the multi-pass Thomson scattering system in GAMMA 10/PDX.

    PubMed

    Yoshikawa, Masayuki; Yasuhara, Ryo; Ohta, Koichi; Chikatsu, Masayuki; Shima, Yoriko; Kohagura, Junko; Sakamoto, Mizuki; Nakashima, Yousuke; Imai, Tsuyoshi; Ichimura, Makoto; Yamada, Ichihiro; Funaba, Hisamichi; Minami, Takashi

    2016-11-01

    High time resolved electron temperature measurements are useful for fluctuation study. A multi-pass Thomson scattering (MPTS) system is proposed for the improvement of both increasing the TS signal intensity and time resolution. The MPTS system in GAMMA 10/PDX has been constructed for enhancing the Thomson scattered signals for the improvement of measurement accuracy. The MPTS system has a polarization-based configuration with an image relaying system. We optimized the image relaying optics for improving the multi-pass laser confinement and obtaining the stable MPTS signals over ten passing TS signals. The integrated MPTS signals increased about five times larger than that in the single pass system. Finally, time dependent electron temperatures were obtained in MHz sampling.

  11. Validation of the one pass measure for motivational interviewing competence.

    PubMed

    McMaster, Fiona; Resnicow, Ken

    2015-04-01

    This paper examines the psychometric properties of the OnePass coding system: a new, user-friendly tool for evaluating practitioner competence in motivational interviewing (MI). We provide data on reliability and validity with the current gold-standard: Motivational Interviewing Treatment Integrity tool (MITI). We compared scores from 27 videotaped MI sessions performed by student counselors trained in MI and simulated patients using both OnePass and MITI, with three different raters for each tool. Reliability was estimated using intra-class coefficients (ICCs), and validity was assessed using Pearson's r. OnePass had high levels of inter-rater reliability with 19/23 items found from substantial to almost perfect agreement. Taking the pair of scores with the highest inter-rater reliability on the MITI, the concurrent validity between the two measures ranged from moderate to high. Validity was highest for evocation, autonomy, direction and empathy. OnePass appears to have good inter-rater reliability while capturing similar dimensions of MI as the MITI. Despite the moderate concurrent validity with the MITI, the OnePass shows promise in evaluating both traditional and novel interpretations of MI. OnePass may be a useful tool for developing and improving practitioner competence in MI where access to MITI coders is limited. Copyright © 2015. Published by Elsevier Ireland Ltd.

  12. Enhancing sensitivity of biconical tapered fiber sensors with multiple passes through the taper

    NASA Astrophysics Data System (ADS)

    Cohoon, Gregory; Boyter, Chris; Errico, Michael; Vandervoort, Kurt; Salik, Ertan

    2010-03-01

    A single biconical fiber taper is a simple and low-cost yet powerful sensor. With a distinct strength in refractive index (RI) sensing, biconical tapered fiber sensors can find their place in handheld sensor platforms, especially as biosensors that are greatly needed in health care, environmental protection, food safety, and biodefense. We report doubling of sensitivity for these sensors with two passes through the tapered region, which becomes possible through the use of sensitive and high-dynamic-range photodetectors. In a proof-of-principle experiment, we measured transmission through the taper when it was immersed in isopropyl alcohol-water mixtures of varying concentrations, in which a thin gold layer at the tip of the fiber acted as a mirror enabling two passes through the tapered region. This improved the sensitivity from 0.43 dB/vol % in the single-pass case to 0.78 dB/vol % with two passes through the taper. The refractive index detection limit was estimated to be ~1.2×10-5 RI units (RIU) and ~0.6×10-5 RIU in the single- and double-pass schemes, respectively. We predict that further enhancement of sensitivity may be achieved with a higher number of passes through the taper.

  13. SU-F-T-301: Planar Dose Pass Rate Inflation Due to the MapCHECK Measurement Uncertainty Function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bailey, D; Spaans, J; Kumaraswamy, L

    Purpose: To quantify the effect of the Measurement Uncertainty function on planar dosimetry pass rates, as analyzed with Sun Nuclear Corporation analytic software (“MapCHECK” or “SNC Patient”). This optional function is toggled on by default upon software installation, and automatically increases the user-defined dose percent difference (%Diff) tolerance for each planar dose comparison. Methods: Dose planes from 109 IMRT fields and 40 VMAT arcs were measured with the MapCHECK 2 diode array, and compared to calculated planes from a commercial treatment planning system. Pass rates were calculated within the SNC analytic software using varying calculation parameters, including Measurement Uncertainty onmore » and off. By varying the %Diff criterion for each dose comparison performed with Measurement Uncertainty turned off, an effective %Diff criterion was defined for each field/arc corresponding to the pass rate achieved with MapCHECK Uncertainty turned on. Results: For 3%/3mm analysis, the Measurement Uncertainty function increases the user-defined %Diff by 0.8–1.1% average, depending on plan type and calculation technique, for an average pass rate increase of 1.0–3.5% (maximum +8.7%). For 2%, 2 mm analysis, the Measurement Uncertainty function increases the user-defined %Diff by 0.7–1.2% average, for an average pass rate increase of 3.5–8.1% (maximum +14.2%). The largest increases in pass rate are generally seen with poorly-matched planar dose comparisons; the MapCHECK Uncertainty effect is markedly smaller as pass rates approach 100%. Conclusion: The Measurement Uncertainty function may substantially inflate planar dose comparison pass rates for typical IMRT and VMAT planes. The types of uncertainties incorporated into the function (and their associated quantitative estimates) as described in the software user’s manual may not accurately estimate realistic measurement uncertainty for the user’s measurement conditions. Pass rates listed in published reports or otherwise compared to the results of other users or vendors should clearly indicate whether the Measurement Uncertainty function is used.« less

  14. Psychometric Properties of an Arabic Pain Anxiety Symptoms Scale-20 (PASS-20) in Healthy Volunteers and Patients Attending a Physiotherapy Clinic.

    PubMed

    Tashani, Osama A; AlAbas, Oras A; Kabil, Raafat A M; Johnson, Mark I

    2017-06-01

    The aim of this study was to cross-culturally adapt the PASS-20 questionnaire for use in Libya. Participants were 71 patients (42 women) attending the physiotherapy clinic, Ibn Sina Hospital, Sirt, Libya for management of persistent pain and 137 healthy unpaid undergraduate students (52 women) from the University of Sirt, Libya. The English PASS-20 was translated into Arabic. Patients completed the Arabic PASS-20 and the Arabic Pain Rating Scales on two occasions separated by a 14-day interval. Healthy participants completed the Arabic PASS-20 on one occasion. The internal consistency (ICC) for pain patient and healthy participant samples yielded a good reliability for the total score, cognitive anxiety, fear of pain, and physiological anxiety. The test-retest reliability of the Arabic PASS-20 score showed high reliability for the total score (ICC = 0.93, p < 0.001), escape/avoidance (ICC = 0.93, p < 0.001), fear of pain (ICC = 0.94, p < 0.001), and physiological anxiety subscales (ICC = 0.96, p < 0.001) and good reliability for the cognitive anxiety (ICC = 0.85, p < 0.001). Inspection of the Promax rotation showed that each factor comprised of five items were consistent with the theoretical constructs of the original PASS-20 subscales. The Arabic PASS-20 retained internal consistency and reliability with the original English version and can be used to measure pain anxiety symptoms in both pain and healthy individual samples in Libya.

  15. The Physical Therapy and Society Summit (PASS) Meeting: observations and opportunities.

    PubMed

    Kigin, Colleen M; Rodgers, Mary M; Wolf, Steven L

    2010-11-01

    The construct of delivering high-quality and cost-effective health care is in flux, and the profession must strategically plan how to meet the needs of society. In 2006, the House of Delegates of the American Physical Therapy Association passed a motion to convene a summit on "how physical therapists can meet current, evolving, and future societal health care needs." The Physical Therapy and Society Summit (PASS) meeting on February 27-28, 2009, in Leesburg, Virginia, sent a clear message that for physical therapists to be effective and thrive in the health care environment of the future, a paradigm shift is required. During the PASS meeting, participants reframed our traditional focus on the physical therapist and the patient/client (consumer) to one in which physical therapists are an integral part of a collaborative, multidisciplinary health care team with the health care consumer as its focus. The PASS Steering Committee recognized that some of the opportunities that surfaced during the PASS meeting may be disruptive or may not be within the profession's present strategic or tactical plans. Thus, adopting a framework that helps to establish the need for change that is provocative and potentially disruptive to our present care delivery, yet prioritizes opportunities, is a critical and essential step. Each of us in the physical therapy profession must take on post-PASS roles and responsibilities to accomplish the systemic change that is so intimately intertwined with our destiny. This article offers a perspective of the dynamic dialogue and suggestions that emerged from the PASS event, providing further opportunities for discussion and action within our profession.

  16. 40 CFR 91.608 - Compliance with acceptable quality level and passing and failing criteria for selective...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... level and passing and failing criteria for selective enforcement audits. 91.608 Section 91.608... with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final test...

  17. 40 CFR 89.510 - Compliance with acceptable quality level and passing and failing criteria for selective...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... level and passing and failing criteria for selective enforcement audits. 89.510 Section 89.510... Compliance with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final...

  18. 40 CFR 89.510 - Compliance with acceptable quality level and passing and failing criteria for selective...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... level and passing and failing criteria for selective enforcement audits. 89.510 Section 89.510... Compliance with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final...

  19. 40 CFR 91.608 - Compliance with acceptable quality level and passing and failing criteria for selective...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... level and passing and failing criteria for selective enforcement audits. 91.608 Section 91.608... with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final test...

  20. 40 CFR 91.608 - Compliance with acceptable quality level and passing and failing criteria for selective...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... level and passing and failing criteria for selective enforcement audits. 91.608 Section 91.608... with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final test...

  1. Medical Educators' Social Acts of Explaining Passing Underperformance in Students: A Qualitative Study

    ERIC Educational Resources Information Center

    Monrouxe, Lynn V.; Rees, Charlotte E.; Lewis, Natalie J.; Cleland, Jennifer A.

    2011-01-01

    Passing underperformance in students is ubiquitous across health and social care educators and is intimately related to the subsequent welfare of patients: underperforming students may become underperforming practitioners. This paper aims to examine how medical educators construct passing underperformance through an analysis of their social act of…

  2. Bridging the Gap in Volleyball. From Basic Instruction to Game Play.

    ERIC Educational Resources Information Center

    Dawson, Linda; Polvino, Geri

    1982-01-01

    Using volleyball "mini games," which emphasize, one at a time, skills needed to play volleyball, helps students to develop skills needed to play. Mini games described are: (1) forearm pass; (2) overhand pass; (3) overhand pass; (4) overhand serve; (5) mini volleyball; and (6) alternate court set-up. (CJ)

  3. 14 CFR 61.35 - Knowledge test: Prerequisites and passing grades.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Knowledge test: Prerequisites and passing....35 Knowledge test: Prerequisites and passing grades. (a) An applicant for a knowledge test must have... part for the certificate or rating sought and is prepared for the knowledge test; and (2) Proper...

  4. 14 CFR 61.35 - Knowledge test: Prerequisites and passing grades.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Knowledge test: Prerequisites and passing....35 Knowledge test: Prerequisites and passing grades. (a) An applicant for a knowledge test must have... part for the certificate or rating sought and is prepared for the knowledge test; and (2) Proper...

  5. 14 CFR 61.35 - Knowledge test: Prerequisites and passing grades.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Knowledge test: Prerequisites and passing....35 Knowledge test: Prerequisites and passing grades. (a) An applicant for a knowledge test must have... part for the certificate or rating sought and is prepared for the knowledge test; and (2) Proper...

  6. South Africa?s Increased Matriculation Passes: What Skunks behind the Rose?

    ERIC Educational Resources Information Center

    Monyooe, Lebusa; Tjatji, Martin; Mosese, Eulenda

    2014-01-01

    This article argues that the exponential increases in the Grade 12 (Matriculation) passes post 1994 do not necessarily translate to quality because of the low performance norms and standards set for passing Grade 12. It further calls for a serious reflection and interrogation of existing policies on performance, benchmarks, teacher education…

  7. 47 CFR 80.1011 - Transmitter.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Mississippi River from the territorial sea boundary, and within either the Southwest Pass safety fairway or the South Pass safety fairway specified in § 166.200 of the U.S. Coast Guard's Rules, 33 CFR 166.200, to mile 242.4 AHP (Above Head of Passes) near Baton Rouge; (2) The Mississippi River-Gulf Outlet from...

  8. 47 CFR 80.1011 - Transmitter.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Mississippi River from the territorial sea boundary, and within either the Southwest Pass safety fairway or the South Pass safety fairway specified in § 166.200 of the U.S. Coast Guard's Rules, 33 CFR 166.200, to mile 242.4 AHP (Above Head of Passes) near Baton Rouge; (2) The Mississippi River-Gulf Outlet from...

  9. 33 CFR 80.825 - Mississippi Passes, LA.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28°54.5′ N., longitude 89°26.1′ W. (d) A line drawn from Mississippi River South Pass East Jetty Light 4 to Mississippi River South Pass West Jetty Light; thence following the general trend of the... general trend of the seaward, highwater shoreline in a southwesterly direction to Mississippi River...

  10. 47 CFR 80.1011 - Transmitter.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Mississippi River from the territorial sea boundary, and within either the Southwest Pass safety fairway or the South Pass safety fairway specified in § 166.200 of the U.S. Coast Guard's Rules, 33 CFR 166.200, to mile 242.4 AHP (Above Head of Passes) near Baton Rouge; (2) The Mississippi River-Gulf Outlet from...

  11. 47 CFR 80.1011 - Transmitter.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Mississippi River from the territorial sea boundary, and within either the Southwest Pass safety fairway or the South Pass safety fairway specified in § 166.200 of the U.S. Coast Guard's Rules, 33 CFR 166.200, to mile 242.4 AHP (Above Head of Passes) near Baton Rouge; (2) The Mississippi River-Gulf Outlet from...

  12. 47 CFR 80.1011 - Transmitter.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Mississippi River from the territorial sea boundary, and within either the Southwest Pass safety fairway or the South Pass safety fairway specified in § 166.200 of the U.S. Coast Guard's Rules, 33 CFR 166.200, to mile 242.4 AHP (Above Head of Passes) near Baton Rouge; (2) The Mississippi River-Gulf Outlet from...

  13. 33 CFR 80.825 - Mississippi Passes, LA.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28°54.5′ N., longitude 89°26.1′ W. (d) A line drawn from Mississippi River South Pass East Jetty Light 4 to Mississippi River South Pass West Jetty Light; thence following the general trend of the... general trend of the seaward, highwater shoreline in a southwesterly direction to Mississippi River...

  14. 14 CFR 399.82 - Passing off of carrier identity by affiliation between carriers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Passing off of carrier identity by... Relating to Enforcement § 399.82 Passing off of carrier identity by affiliation between carriers. (a... points served by both carriers should preserve the identity of the individual carriers; (5) Where joint...

  15. 40 CFR 90.510 - Compliance with acceptable quality level and passing and failing criteria for selective...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Compliance with acceptable quality level and passing and failing criteria for selective enforcement audits. 90.510 Section 90.510....510 Compliance with acceptable quality level and passing and failing criteria for selective...

  16. 78 FR 50405 - Amended Application for Presidential Permit; Northern Pass Transmission LLC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-19

    ... project would adversely affect the operation of the U.S. electric power supply system under normal and... proposed project. Northern Pass is wholly owned by NU Transmission Ventures, Inc., a wholly-owned..., that would meet the needs of the Project.'' On July 1, 2013, Northern Pass submitted an amended...

  17. 7 CFR 52.1845 - Sizes of seedless raisins.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... percent, by weight, of all the raisins will pass through round perforations 22/64-inch in diameter, but not more than 10 percent, by weight, of all the raisins may pass through round perforations 20/64-inch... will pass through round perforations 24/64-inch in diameter, and not less than 70 percent, by weight...

  18. 7 CFR 52.1845 - Sizes of seedless raisins.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... percent, by weight, of all the raisins will pass through round perforations 22/64-inch in diameter, but not more than 10 percent, by weight, of all the raisins may pass through round perforations 20/64-inch... will pass through round perforations 24/64-inch in diameter, and not less than 70 percent, by weight...

  19. 7 CFR 52.1845 - Sizes of seedless raisins.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... raisins will pass through round perforations 22/64-inch in diameter, but not more than 10 percent, by weight, of all the raisins may pass through round perforations 20/64-inch in diameter. (b) Small or midget size raisins means that 95 percent, by weight, of all the raisins will pass through round...

  20. 14 CFR 399.82 - Passing off of carrier identity by affiliation between carriers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Passing off of carrier identity by... Relating to Enforcement § 399.82 Passing off of carrier identity by affiliation between carriers. (a... points served by both carriers should preserve the identity of the individual carriers; (5) Where joint...

  1. 14 CFR 399.82 - Passing off of carrier identity by affiliation between carriers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Passing off of carrier identity by... Relating to Enforcement § 399.82 Passing off of carrier identity by affiliation between carriers. (a... points served by both carriers should preserve the identity of the individual carriers; (5) Where joint...

  2. 14 CFR 399.82 - Passing off of carrier identity by affiliation between carriers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Passing off of carrier identity by... Relating to Enforcement § 399.82 Passing off of carrier identity by affiliation between carriers. (a... points served by both carriers should preserve the identity of the individual carriers; (5) Where joint...

  3. 14 CFR 399.82 - Passing off of carrier identity by affiliation between carriers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Passing off of carrier identity by... Relating to Enforcement § 399.82 Passing off of carrier identity by affiliation between carriers. (a... points served by both carriers should preserve the identity of the individual carriers; (5) Where joint...

  4. 78 FR 18480 - Drawbridge Operation Regulations; Chef Menteur Pass, at Lake Catherine, LA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-27

    ... Operation Regulations; Chef Menteur Pass, at Lake Catherine, LA AGENCY: Coast Guard, DHS. ACTION: Notice of..., mile 2.8, at Lake Catherine, Orleans Parish, Louisiana. The deviation is necessary to ensure the safety.... Highway 90 swing bridge crossing the Chef Menteur Pass, mile 2.8, at Lake Catherine, Orleans, Parish...

  5. 9 CFR 310.8 - Passing and marking of carcasses and parts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Passing and marking of carcasses and parts. 310.8 Section 310.8 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF... INSPECTION AND CERTIFICATION POST-MORTEM INSPECTION § 310.8 Passing and marking of carcasses and parts...

  6. Analyzing Driver Behavior in Passing Zones with Differential Speed Limits on Two-Lane Two-Way Undivided Highways in Alaska

    DOT National Transportation Integrated Search

    2017-12-01

    Due to the relatively high crash rates attributed to two lane highways in Alaska, solutions have been explored to improve safety by providing passing lanes to give drivers a better chance to pass the slow moving vehicles. Drivers of slow moving vehic...

  7. 77 FR 20719 - Safety Zone; Matlacha Bridge Construction, Matlacha Pass, Matlacha, FL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-06

    ...-AA00 Safety Zone; Matlacha Bridge Construction, Matlacha Pass, Matlacha, FL AGENCY: Coast Guard, DHS... waters of Matlacha Pass in the vicinity of the Matlacha Bridge in Matlacha, Florida. The safety zone will be enforced during construction of the Matlacha Bridge from Monday, March 12, 2012 through Tuesday...

  8. 77 FR 1870 - Safety Zone; Matlacha Bridge Construction, Matlacha Pass, Matlacha, FL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-12

    ...-AA00 Safety Zone; Matlacha Bridge Construction, Matlacha Pass, Matlacha, FL AGENCY: Coast Guard, DHS... waters of Matlacha Pass in the vicinity of the Matlacha Bridge in Matlacha, Florida. The safety zone will be enforced during construction of the Matlacha Bridge from Thursday, December 15, 2011 until Sunday...

  9. Making the Grade: How Learner Engagement Changes after Passing a Course

    ERIC Educational Resources Information Center

    Lang, David; Kindel, Alex; Domingue, Ben; Paepcke, Andreas

    2017-01-01

    Understanding how individuals interact with a course after receiving a passing grade could have important implications for course design. If individuals become disengaged after passing a class, then this may raise questions about optimal ordering of content, course difficulty, and grade transparency. Using a person fixed effects model, we analyze…

  10. Try, Try, Again: A Two-Step Strategy for Passing School Levies

    ERIC Educational Resources Information Center

    Johnson, Paul A.

    2008-01-01

    Passing property tax issues is an increasing challenge for many school districts. This article examines 21 school levy strategies identified through a literature review associated with successful school levy campaigns. These strategies were then used as a framework to evaluate one district's attempts to pass a school bond levy. Whereas the study…

  11. The Objective Borderline method (OBM): a probability-based model for setting up an objective pass/fail cut-off score in medical programme assessments.

    PubMed

    Shulruf, Boaz; Turner, Rolf; Poole, Phillippa; Wilkinson, Tim

    2013-05-01

    The decision to pass or fail a medical student is a 'high stakes' one. The aim of this study is to introduce and demonstrate the feasibility and practicality of a new objective standard-setting method for determining the pass/fail cut-off score from borderline grades. Three methods for setting up pass/fail cut-off scores were compared: the Regression Method, the Borderline Group Method, and the new Objective Borderline Method (OBM). Using Year 5 students' OSCE results from one medical school we established the pass/fail cut-off scores by the abovementioned three methods. The comparison indicated that the pass/fail cut-off scores generated by the OBM were similar to those generated by the more established methods (0.840 ≤ r ≤ 0.998; p < .0001). Based on theoretical and empirical analysis, we suggest that the OBM has advantages over existing methods in that it combines objectivity, realism, robust empirical basis and, no less importantly, is simple to use.

  12. Microstructure, Texture and Mechanical Properties of Titanium Grade 2 Processed by ECAP (Route C)

    NASA Astrophysics Data System (ADS)

    Wroński, M.; Wierzbanowski, K.; Wojtas, D.; Szyfner, E.; Valiev, R. Z.; Kawałko, J.; Berent, K.; Sztwiertnia, K.

    2018-03-01

    In the present work the properties of titanium grade 2 after ECAP processing with original route and regimes (route C, channel angle Φ= 120°, deformation temperature 300 °C, number of passes up to 8) were examined. Texture development and microstructure parameters after ECAP processing and after recrystallization were determined using electron back scatter diffraction and analysed. A significant increase of the mechanical strength accompanied by some increase of ductility was observed in the deformed samples. The kernel average misorientation and average grain orientation spread were strongly increased after deformation, which confirms the material refinement and fragmentation. The proportion of low angle boundaries increased after four ECAP passes, but after four consecutive passes high angle grain boundaries became predominant. No deformation twins were observed after four and eight ECAP passes. The material recrystallized after deformation retained a fine grain microstructure. The textures of deformed and recrystallized samples were determined. It was found that texture after 8 passes is more homogeneous that that after 4 passes, which partly explains higher ductility of this first sample.

  13. The utility of mock oral examinations in preparation for the American Board of Surgery certifying examination.

    PubMed

    Higgins, Rana M; Deal, Rebecca A; Rinewalt, Daniel; Hollinger, Edward F; Janssen, Imke; Poirier, Jennifer; Austin, Delores; Rendina, Megan; Francescatti, Amanda; Myers, Jonathan A; Millikan, Keith W; Luu, Minh B

    2016-02-01

    Determine the utility of mock oral examinations in preparation for the American Board of Surgery certifying examination (ABS CE). Between 2002 and 2012, blinded data were collected on 63 general surgery residents: 4th and 5th-year mock oral examination scores, first-time pass rates on ABS CE, and an online survey. Fifty-seven residents took the 4th-year mock oral examination: 30 (52.6%) passed and 27 (47.4%) failed, with first-time ABS CE pass rates 93.3% and 81.5% (P = .238). Fifty-nine residents took the 5th-year mock oral examination: 28 (47.5%) passed and 31 (52.5%) failed, with first-time ABS CE pass rates 82.1% and 93.5% (P = .240). Thirty-eight responded to the online survey, 77.1% ranked mock oral examinations as very or extremely helpful with ABS CE preparation. Although mock oral examinations and ABS CE passing rates do not directly correlate, residents perceive the mock oral examinations to be helpful. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Multi-focus image fusion based on area-based standard deviation in dual tree contourlet transform domain

    NASA Astrophysics Data System (ADS)

    Dong, Min; Dong, Chenghui; Guo, Miao; Wang, Zhe; Mu, Xiaomin

    2018-04-01

    Multiresolution-based methods, such as wavelet and Contourlet are usually used to image fusion. This work presents a new image fusion frame-work by utilizing area-based standard deviation in dual tree Contourlet trans-form domain. Firstly, the pre-registered source images are decomposed with dual tree Contourlet transform; low-pass and high-pass coefficients are obtained. Then, the low-pass bands are fused with weighted average based on area standard deviation rather than the simple "averaging" rule. While the high-pass bands are merged with the "max-absolute' fusion rule. Finally, the modified low-pass and high-pass coefficients are used to reconstruct the final fused image. The major advantage of the proposed fusion method over conventional fusion is the approximately shift invariance and multidirectional selectivity of dual tree Contourlet transform. The proposed method is compared with wavelet- , Contourletbased methods and other the state-of-the art methods on common used multi focus images. Experiments demonstrate that the proposed fusion framework is feasible and effective, and it performs better in both subjective and objective evaluation.

  15. High Probability of Cyclone Development in the Bay of Bengal

    NASA Image and Video Library

    2014-05-22

    The Joint Typhoon Warning Center states that formation of a significant tropical cyclone is possible in the Bay of Bengal within the next 12 - 24 hours as of 0730Z on May 21, 2014. Along with deep convective banding associated with a consolidating low-level circulation center, warm sea surface temperatures are conducive for further development. This image was taken by the Suomi NPP satellite's VIIRS instrument in two passes, the east pass around 0615Z and the west pass around 0755Z on May 21, 2014. Credit: NASA/NOAA/NPP/VIIRS The Joint Typhoon Warning Center states that formation of a significant tropical cyclone is possible in the Bay of Bengal within the next 12 - 24 hours as of 0730Z on May 21, 2014. Along with deep convective banding associated with a consolidating low-level circulation center, warm sea surface temperatures are conducive for further development. This image was taken by the Suomi NPP satellite's VIIRS instrument in two passes, the east pass around 0615Z and the west pass around 0755Z on May 21, 2014.

  16. Associations Between Five Important Domains of Health and the Patient Acceptable Symptom State in Rheumatoid Arthritis and Psoriatic Arthritis: A Cross-Sectional Study of 977 Patients.

    PubMed

    Puyraimond-Zemmour, Déborah; Etcheto, Adrien; Fautrel, Bruno; Balanescu, Andra; de Wit, Maarten; Heiberg, Turid; Otsa, Kati; Kvien, Tore K; Dougados, Maxime; Gossec, Laure

    2017-10-01

    To explore the link between a patient acceptable symptom state (PASS) and patient-perceived impact in rheumatoid arthritis (RA) and psoriatic arthritis (PsA). This was a cross-sectional study of unselected patients with definite RA or PsA. Pain, functional capacity, fatigue, coping, and sleep disturbance were assessed using a numeric rating scale (0-10) and compared between patients in PASS or not (Cohen's effect sizes). The domains of health associated with PASS status were assessed by multivariate forward logistic regression, and PASS thresholds were determined using the 75th percentile method and receiver operating characteristic analyses. Among 977 patients (531 with RA, 446 with PsA), the mean ± SD age was 53.4 ± 13.2 years, mean ± SD disease duration was 11.2 ± 10.0 years, and 637 (65.8%) were women. In all, 595 patients (60.9%) were in PASS; they had lower symptom levels, and all domains of health except sleep disturbance discriminated clearly between patients in PASS or not (effect sizes 0.73-1.45 in RA and 0.82-1.52 in PsA). In multivariate analysis, less pain and better coping were predictive of being in PASS. Odds ratios were: RA pain 0.80 (95% confidence interval [95% CI] 0.67-0.96), PsA pain 0.63 (95% CI 0.52-0.75), RA coping 0.84 (95% CI 0.74-0.96), and PsA coping 0.83 (95% CI 0.71-0.97). The cutoffs of symptom intensity (range 0-10), corresponding to PASS for the 5 domains of health and the 2 diseases were similar, i.e., approximately 4-5. In RA and PsA, PASS was associated with the 5 domains of health analyzed, and in particular with less pain and better coping. © 2016, American College of Rheumatology.

  17. Equal Channel Angular Pressing (ECAP) and Its Application to Grain Refinement of Al-Zn-Mg-Cu Alloy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tekeli, Sueleyman; Gueral, Ahmet

    Microstructure of a metal can be considerably changed by severe plastic deformation techniques such as high pressure torsion, extrusion and equal-channel angular pressing (ECAP). Among these methods, ECAP is particularly attractive because it has a potential for introducing significant grain refinement and homogeneous microstructure into bulk materials. Typically, it reduces the grain size to the submicrometer level or even nanometer range and thus produces materials that are capable of exhibiting unusual mechanical properties. In the present study, a test unites for equal channel angular pressing was constructed and this system was used for Al-Zn-Mg-Cu alloy. After the optimization tests, itmore » was seen that the most effective lubricant for the dies was MoS{sub 2}, the pressing pressure was around 25-35 ton and the pressing speed was 2 mm/s. By using these parameters, the Al-Zn-Mg-Cu alloy was successfully ECAPed up to 14 passes at 200 deg. C using route C. After ECAP tests, the specimens were characterized by transmission electron microscope (TEM), hardness and macrostructural investigations. It was seen that the plastic deformation in the ECAPed specimens occurred from edge to the centre like whirlpool. In addition, the deformation intensity increased with increasing pass number. The grain size of the specimens effectively also decreased with increasing pass number. That is, while the grain size of unECAPed specimen was 10 {mu}m, this value decreased to 300 nm after 14 passes. At the beginning, while there was a banding tendency in the grains toward deformation direction, homogeneous and equiaxed grains were formed with increasing pass number. This grain refinement was as a result of an interaction between shear strain and thermal recovery during ECAP processing. Hardness measurements showed that the hardness values increased up to 4 passes, decreased effectively at 6th pass, again increased at 8th pass and after this pass, the hardness again decreased due to dynamic recrystallization.« less

  18. The Diagnostic Validity and Reliability of an Internet-Based Clinical Assessment Program for Mental Disorders

    PubMed Central

    Klein, Britt; Meyer, Denny; Austin, David William; Abbott, Jo-Anne M

    2015-01-01

    Background Internet-based assessment has the potential to assist with the diagnosis of mental health disorders and overcome the barriers associated with traditional services (eg, cost, stigma, distance). Further to existing online screening programs available, there is an opportunity to deliver more comprehensive and accurate diagnostic tools to supplement the assessment and treatment of mental health disorders. Objective The aim was to evaluate the diagnostic criterion validity and test-retest reliability of the electronic Psychological Assessment System (e-PASS), an online, self-report, multidisorder, clinical assessment and referral system. Methods Participants were 616 adults residing in Australia, recruited online, and representing prospective e-PASS users. Following e-PASS completion, 158 participants underwent a telephone-administered structured clinical interview and 39 participants repeated the e-PASS within 25 days of initial completion. Results With structured clinical interview results serving as the gold standard, diagnostic agreement with the e-PASS varied considerably from fair (eg, generalized anxiety disorder: κ=.37) to strong (eg, panic disorder: κ=.62). Although the e-PASS’ sensitivity also varied (0.43-0.86) the specificity was generally high (0.68-1.00). The e-PASS sensitivity generally improved when reducing the e-PASS threshold to a subclinical result. Test-retest reliability ranged from moderate (eg, specific phobia: κ=.54) to substantial (eg, bulimia nervosa: κ=.87). Conclusions The e-PASS produces reliable diagnostic results and performs generally well in excluding mental disorders, although at the expense of sensitivity. For screening purposes, the e-PASS subclinical result generally appears better than a clinical result as a diagnostic indicator. Further development and evaluation is needed to support the use of online diagnostic assessment programs for mental disorders. Trial Registration Australian and New Zealand Clinical Trials Registry ACTRN121611000704998; http://www.anzctr.org.au/trial_view.aspx?ID=336143 (Archived by WebCite at http://www.webcitation.org/618r3wvOG). PMID:26392066

  19. Does the endolymph pass through the base of the cupula?

    NASA Astrophysics Data System (ADS)

    Jijiwa, H.; Watanabe, N.; Hattori, T.; Matuda, F.; Hashiba, M.; Mizuno, Y.; Shindo, M.; Watanabe, S.

    2001-08-01

    Whether the endolymph of the semicircular canal passes the cupular partition or not was examined using the lateral semicircular canal system of adult pigeons (Columba livia). By applying various pressures by means of injection of a dye solution through the membranous canal, it was found that the dye solution was seen to pass the cupula even under very low pressures when the pressure was increased gradually. When pulled by a magnet, the ultrafine particles of the dextran magnetite contained in the injected fluid were found to pass through the subcupular space without evident increase of the ampullary pressure.

  20. High Speed Edge Detection

    NASA Technical Reports Server (NTRS)

    Prokop, Norman F (Inventor)

    2016-01-01

    Analog circuits for detecting edges in pixel arrays are disclosed. A comparator may be configured to receive an all pass signal and a low pass signal for a pixel intensity in an array of pixels. A latch may be configured to receive a counter signal and a latching signal from the comparator. The comparator may be configured to send the latching signal to the latch when the all pass signal is below the low pass signal minus an offset. The latch may be configured to hold a last negative edge location when the latching signal is received from the comparator.

  1. High Speed Edge Detection

    NASA Technical Reports Server (NTRS)

    Prokop, Norman F (Inventor)

    2015-01-01

    Analog circuits for detecting edges in pixel arrays are disclosed. A comparator may be configured to receive an all pass signal and a low pass signal for a pixel intensity in an array of pixels. A latch may be configured to receive a counter signal and a latching signal from the comparator. The comparator may be configured to send the latching signal to the latch when the all pass signal is below the low pass signal minus an offset. The latch may be configured to hold a last negative edge location when the latching signal is received from the comparator.

  2. Evaluating single-pass catch as a tool for identifying spatial pattern in fish distribution

    USGS Publications Warehouse

    Bateman, Douglas S.; Gresswell, Robert E.; Torgersen, Christian E.

    2005-01-01

    We evaluate the efficacy of single-pass electrofishing without blocknets as a tool for collecting spatially continuous fish distribution data in headwater streams. We compare spatial patterns in abundance, sampling effort, and length-frequency distributions from single-pass sampling of coastal cutthroat trout (Oncorhynchus clarki clarki) to data obtained from a more precise multiple-pass removal electrofishing method in two mid-sized (500–1000 ha) forested watersheds in western Oregon. Abundance estimates from single- and multiple-pass removal electrofishing were positively correlated in both watersheds, r = 0.99 and 0.86. There were no significant trends in capture probabilities at the watershed scale (P > 0.05). Moreover, among-sample variation in fish abundance was higher than within-sample error in both streams indicating that increased precision of unit-scale abundance estimates would provide less information on patterns of abundance than increasing the fraction of habitat units sampled. In the two watersheds, respectively, single-pass electrofishing captured 78 and 74% of the estimated population of cutthroat trout with 7 and 10% of the effort. At the scale of intermediate-sized watersheds, single-pass electrofishing exhibited a sufficient level of precision to be effective in detecting spatial patterns of cutthroat trout abundance and may be a useful tool for providing the context for investigating fish-habitat relationships at multiple scales.

  3. Cigarette Smoke Cadmium Breakthrough from Traditional Filters: Implications for Exposure

    PubMed Central

    Pappas, R. Steven; Fresquez, Mark R.; Watson, Clifford H.

    2015-01-01

    Cadmium, a carcinogenic metal, is highly toxic to renal, skeletal, nervous, respiratory, and cardiovascular systems. Accurate and precise quantification of mainstream smoke cadmium levels in cigarette smoke is important because of exposure concerns. The two most common trapping techniques for collecting mainstream tobacco smoke particulate for analysis are glass fiber filters and electrostatic precipitators. We observed that a significant portion of total cadmium passed through standard glass fiber filters that are used to trap particulate matter. We therefore developed platinum traps to collect the cadmium that passed through the filters and tested a variety of cigarettes with different physical parameters for quantities of cadmium that passed though the filters. We found less than 1% cadmium passed through electrostatic precipitators. In contrast, cadmium that passed through 92 mm glass fiber filters on a rotary smoking machine was significantly higher, ranging from 3.5% to 22.9% of total smoke cadmium deliveries. Cadmium passed through 44 mm filters typically used on linear smoking machines to an even greater degree, ranging from 13.6% to 30.4% of the total smoke cadmium deliveries. Differences in the cadmium that passed through from the glass fiber filters and electrostatic precipitator could be explained in part if cadmium resides in the smaller mainstream smoke aerosol particle sizes. Differences in particle size distribution could have toxicological implications and could help explain the pulmonary and cardiovascular cadmium uptake in smokers. PMID:25313385

  4. Impacts after four years of experimental trampling on alpine/sub-alpine environments in western Tasmania.

    PubMed

    Whinam, Jennie; Chilcott, Nicole M

    2003-04-01

    Experimental trials were undertaken over four years to assess the impact of recreational trampling in undisturbed alpine and sub-alpine vegetation communities in the Western Arthur Range, western Tasmania. Data on 'pad' formation due to human trampling were collected using vegetation cover assessments, biomass estimates and detailed cross-sectional surface profiles. In sub-alpine buttongrass and alpine herbfield, prolonged and sustained damage may occur after 100 passes by walkers. The environmental threshold of the flat alpine herbfield site was breached after 200 passes. Plant morphology was one determinant of resistance and resilience, with upright woody shrubs and tall tussock graminoids most vulnerable to sustained trampling damage. Cushions are susceptible to trampling impacts at 500 passes. Loss of vegetation cover peaks 6-12 months after trampling. Our results show that pads formed with as few as 30-100 passes per annum and tracks form at between 100 and 500 passes per annum. Two years after the cessation of trampling, there is some small recovery in vegetation cover after 30 and 100 passes per annum applied for three years, but no evidence of recovery at the 500 pass treatments. The low trampling threshold and slow recovery rates in western Tasmania suggest that concentrating walkers on a minimal number of sites may be the best management option for these untracked alpine and sub-alpine environments.

  5. A Student Experience of Peer Assisted Study Sessions in Physiotherapy

    ERIC Educational Resources Information Center

    Sole, Gisela; Rose, Andrew; Bennet, Tracey; Jaques, Katrina; Rippon, Zoe; van der Meer, Jacques

    2012-01-01

    Peer Assisted Study Sessions (PASS) were introduced as an optional learning experience in a Bachelor of Physiotherapy programme. The aim of this study was to evaluate the use of PASS from the student perspective. Eight third year physiotherapy students who had participated in PASS during their second year of training attended a focus group, at…

  6. 40 CFR 90.510 - Compliance with acceptable quality level and passing and failing criteria for selective...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... level and passing and failing criteria for selective enforcement audits. 90.510 Section 90.510....510 Compliance with acceptable quality level and passing and failing criteria for selective... failed engine is an engine whose final test results pursuant to § 90.509(b), for one or more of the...

  7. 40 CFR 86.610-98 - Compliance with acceptable quality level and passing and failing criteria for Selective...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... quality level and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results...

  8. 40 CFR 86.610-98 - Compliance with acceptable quality level and passing and failing criteria for Selective...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... quality level and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results...

  9. 40 CFR 86.610-98 - Compliance with acceptable quality level and passing and failing criteria for Selective...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... quality level and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results...

  10. 40 CFR 86.610-98 - Compliance with acceptable quality level and passing and failing criteria for Selective...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results pursuant to...

  11. 40 CFR 86.610-98 - Compliance with acceptable quality level and passing and failing criteria for Selective...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... quality level and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results...

  12. 40 CFR 90.510 - Compliance with acceptable quality level and passing and failing criteria for selective...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... level and passing and failing criteria for selective enforcement audits. 90.510 Section 90.510....510 Compliance with acceptable quality level and passing and failing criteria for selective... failed engine is an engine whose final test results pursuant to § 90.509(b), for one or more of the...

  13. Effect of High-Pass Filtering on the Neonatal Auditory Brainstem Response to Air- and Bone-Conducted Clicks.

    ERIC Educational Resources Information Center

    Stuart, Andrew; Yang, Edward Y.

    1994-01-01

    Simultaneous 3- channel recorded auditory brainstem responses (ABR) were obtained from 20 neonates with various high-pass filter settings and low intensity levels. Results support the advocacy of less restrictive high-pass filtering for neonatal and infant ABR screening to air-conducted and bone-conducted clicks. (Author/JDD)

  14. Military Health Service System Ambulatory Work Unit (AWU).

    DTIC Science & Technology

    1988-04-01

    E-40 BBC-4 Ambulatory Work Unit Distribution Screen Passes BBC - Neurosurgery Clinic .... ............. . E-40 BBD -I Initial Record...Screen Failures BBD - Ophthalmology Clinic ... ............ E-41 BBD -2 Distribution Screen Failures BBD - Ophthalmology Clinic ............ E-41 BBD -3...Descriptive Statistics Distribution Screen Passes BBD - Ophthalmology Clinic ............ E-42 BBD -4 Ambulatory Work Unit Distribution Screen Passes BBD

  15. Pre-Calculus California Content Standards: Standards Deconstruction Project. Version 1.0

    ERIC Educational Resources Information Center

    Arnold, Bruce; Cliffe, Karen; Cubillo, Judy; Kracht, Brenda; Leaf, Abi; Legner, Mary; McGinity, Michelle; Orr, Michael; Rocha, Mario; Ross, Judy; Teegarden, Terrie; Thomson, Sarah; Villero, Geri

    2008-01-01

    This project was coordinated and funded by the California Partnership for Achieving Student Success (Cal-PASS). Cal-PASS is a data sharing system linking all segments of education. Its purpose is to improve student transition and success from one educational segment to the next. Cal-PASS' standards deconstruction project was initiated by the…

  16. The 150 Credit-Hour Requirement and CPA Examination Pass Rates--A Four Year Study

    ERIC Educational Resources Information Center

    Briggs, Gary P.; He, Lerong

    2012-01-01

    Debate concerning the minimum educational requirements of certified public accountant (CPA) candidates in the USA has been taking place for decades. This paper compares the sectional pass rates of CPA candidates from jurisdictions requiring 150 credit hours of college study with the pass rates of candidates from jurisdictions not requiring 150…

  17. Course Pass Rates in Fall 1987. Enrollment Analysis Report EA88-6.

    ERIC Educational Resources Information Center

    Clagett, Craig A.; Diehl, Patricia K.

    A study was conducted at Prince George's Community College (PGCC) in Maryland to determine the percentage of students enrolled in courses in fall 1987 who received passing grades, and to examine these pass rates with respect to academic discipline, and student gender, age, race, and admission status. Study findings included the following: (1) the…

  18. 9 CFR 310.6 - Carcasses and parts passed for cooking; marking.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Carcasses and parts passed for cooking; marking. 310.6 Section 310.6 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF.... Carcasses and parts passed for cooking shall be marked conspicuously on the surface tissues thereof by a...

  19. 9 CFR 310.6 - Carcasses and parts passed for cooking; marking.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Carcasses and parts passed for cooking; marking. 310.6 Section 310.6 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF.... Carcasses and parts passed for cooking shall be marked conspicuously on the surface tissues thereof by a...

  20. 9 CFR 310.6 - Carcasses and parts passed for cooking; marking.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Carcasses and parts passed for cooking; marking. 310.6 Section 310.6 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF.... Carcasses and parts passed for cooking shall be marked conspicuously on the surface tissues thereof by a...

  1. 9 CFR 310.6 - Carcasses and parts passed for cooking; marking.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Carcasses and parts passed for cooking; marking. 310.6 Section 310.6 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF.... Carcasses and parts passed for cooking shall be marked conspicuously on the surface tissues thereof by a...

  2. Use of Online Assessment to Enhance Teaching and Learning: The PASS-IT Project

    ERIC Educational Resources Information Center

    Ashton, Helen; Wood, Christine

    2006-01-01

    This article describes a recent collaborative project (PASS-IT) which investigated the use of online assessment in secondary education in Scotland. The aim of PASS-IT was to explore the potential of formative and summative assessment in secondary education, and to build on previous research into the applicability and validity of online…

  3. Impact of Online Summer Mathematics Bridge Program on Placement Scores and Pass Rates

    ERIC Educational Resources Information Center

    Frost, Jodi L.; Dreher, J. P.

    2017-01-01

    An online four-week summer mathematics bridge program was implemented at a Midwest university with historically low pass rates in College Algebra and Remedial Mathematics. Students who completed the four week program significantly increased their mathematics placement exam scores. These students also had a higher pass rate in their initial college…

  4. 77 FR 12100 - Self-Regulatory Organizations; NASDAQ OMX PHLX LLC; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ... proposes a pass-through reduction in the fees for connectivity to Toronto and Chicago venues as follows: (1... low latency telecommunication carriers. The Exchange is passing along the entire savings of the... passing on the reduction in low latency connectivity fees to the Toronto and Chicago venues to the members...

  5. The Grading Nemesis: An Historical Overview and a Current Look at Pass/Fail Grading.

    ERIC Educational Resources Information Center

    Weller, L. David

    1983-01-01

    A brief history of grading practices at American colleges and universities is given, along with results of a survey of the current uses of pass/fail grading. The pass/fail system is widely used for a limited number of elective courses. Its adoption peaked during the mid-1970s. (PP)

  6. Multiple pass laser amplifier system

    DOEpatents

    Brueckner, Keith A.; Jorna, Siebe; Moncur, N. Kent

    1977-01-01

    A laser amplification method for increasing the energy extraction efficiency from laser amplifiers while reducing the energy flux that passes through a flux limited system which includes apparatus for decomposing a linearly polarized light beam into multiple components, passing the components through an amplifier in delayed time sequence and recombining the amplified components into an in phase linearly polarized beam.

  7. The Dubious Utility of the Value-Added Concept in Higher Education: The Case of Accounting

    ERIC Educational Resources Information Center

    Yunker, J.A.

    2005-01-01

    Using data on CPA exam pass rates and various institutional variables, this research examines the potential usefulness of the value-added concept in accounting higher education. For a sample of 548 US colleges and universities, predicted pass rates were computed from regression equations relating observed pass rates to institutional variables. The…

  8. 77 FR 60165 - Self-Regulatory Organizations; Fixed Income Clearing Corporation; Order Approving Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-02

    ... Time at Which the Mortgage-Backed Securities Division Runs Its Daily Morning Pass September 26, 2012. I... FICC proposes to move the time at which its Mortgage-Backed Securities Division (``MBSD'') runs its... processing passes. MBSD currently runs its first processing pass of the day (historically referred to as the...

  9. 9 CFR 381.79 - Passing of carcasses and parts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Passing of carcasses and parts. 381.79 Section 381.79 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Carcasses and Parts § 381.79 Passing of carcasses and parts. Each carcass and all organs and other parts of...

  10. Examining the Seven-Flag "Chieu Hoi" Pass: A Primary Document from the American War in Viet Nam

    ERIC Educational Resources Information Center

    Engelmann, Ted

    2006-01-01

    During the Viet Nam war, U.S. military helicopters dropped "Chieu Hoi" (safe conduct) passes over suspected enemy locations to encourage enemy soldiers to surrender. This article presents a classroom activity that encourages students to examine a "Chieu Hoi" pass as a primary historical document, identify its various elements,…

  11. Logical Consequences: Using Passing Times to Prevent Misbehavior

    ERIC Educational Resources Information Center

    Harriman, Dion; Pierre, Christina

    2009-01-01

    This article discusses the No Passing Plan, a no-passing policy implemented at White Bear Lake (MN) High School-North Campus in order to prevent chronic tardiness and misbehavior in the halls. The plan is an alternative consequence for administrators to use with students who are disruptive in the halls or consistently tardy to class. Suspending…

  12. Investigating passage of ESA-listed juvenile fall Chinook salmon at Lower Granite Dam during winter when the fish bypass system is not operated

    USGS Publications Warehouse

    Kock, Tobias J.; Tiffan, Kenneth F.; Connor, William P.

    2007-01-01

    During the winter of 2006-07, we radio and passive integrated transponder (PIT) tagged, and released 99 juvenile fall Chinook salmon to evaluate over-wintering behavior and dam passage in the lower Snake River, Washington. All fish were released 10 km upstream of Lower Granite Dam at Granite Point in early November, 2006. Fixed radio telemetry detection sites located in the forebay and tailrace areas of Lower Granite, Little Goose, Lower Monumental, Ice Harbor, Bonneville dams, and at Lyle, Washington were used to monitor fish movements and dam passage through early-May 2007. Of the 99 fish released during our study, 80 passed Lower Granite Dam and were detected at downstream detection sites, 37 passed Little Goose Dam, 41 passed Lower Monumental Dam, 31 passed Ice Harbor Dam, 18 passed Lyle, WA, and 13 passed Bonneville Dam. Of the fish that passed Lower Granite Dam in the fall, 63 fish did so during the extended bypass period from November 1 through December 16. Of these fish, 53 were also detected by the PIT-tag interrogation system. Fifteen of the fish that passed Lower Granite Dam in the fall continued to pass lower Snake River dams and exit the system by the end of January. The remaining fish either died, their tags failed, or they resided in Little Goose Reservoir until spring when relatively few continued their seaward migration. Passage of tagged fish past lower Snake River dams generally declined during the winter as temperatures decreased, but increased again in the spring as temperatures and flows increased. Fish residence times in reservoirs and forebays was lengthy during the winter (up to 160 d), and varied by reservoir and time of year. We observed no diel trends in fish passage. Very few fish were detected at PIT-tag interrogation sites in the spring compared to detection by radio telemetry detection sites indicating that fish may have passed via spill. We believe that passage of overwintering juvenile fall Chinook salmon during winter is due more to chance than directed downstream movement. Since the primary route of passage during the winter is through powerhouse turbines, the potential exists for increased mortality for over-wintering juvenile fall Chinook salmon in the Snake River. Our findings that some fish can pass undetected during the winter likely bias traditional smolt-to-adult return rate calculations that are typically used to measure the success of juvenile transportation studies.

  13. Reliability and Validity of the Pain Anxiety Symptom Scale in Persian Speaking Chronic Low Back Pain Patients.

    PubMed

    Shanbehzadeh, Sanaz; Salavati, Mahyar; Tavahomi, Mahnaz; Khatibi, Ali; Talebian, Saeed; Khademi-Kalantari, Khosro

    2017-11-01

    Psychometric testing of the Persian version of Pain Anxiety Symptom Scale 20. The aim of this study was to assess the reliability and construct validity of the PASS-20 in nonspecific chronic low back pain (LBP) patients. The PASS-20 is a self-report questionnaire that assesses pain-related anxiety. The Psychometric properties of this instrument have not been assessed in Persian-speaking chronic LBP patients. One hundred and sixty participants with chronic LBP completed the Persian version of PASS-20, Tampa Scale of Kinesiophobia (TSK), Fear-Avoidance Beliefs Questionnaire (FABQ), Pain Catastrophizing Scale (PCS), trait form of the State-Trait Anxiety (STAI-T), Oswestry Low Back Pain Disability Index (ODI), Beck Depression Inventory (BDI-II), and Visual Analogue Scale (VAS). To evaluate test-retest reliability, 60 patients filled out the PASS-20, 6 to 8 days after the first visit. Test-retest reliability (intraclass correlation coefficient [ICC], standard error of measurement [SEM], and minimal detectable change [MDC]), internal consistency, dimensionality, and construct validity were examined. The ICCs of the PASS-20 subscales and total score ranged from 0.71 to 0.8. The SEMs for PASS-20 total score was 7.29 and for the subscales ranged from 2.43 to 2.98. The MDC for the total score was 20.14 and for the subscales ranged from 6.71 to 8.23. The Cronbach alpha values for the subscales and total score ranged from 0.70 to 0.91. Significant positive correlations were found between the PASS-20 total score and PCS, TSK, FABQ, ODI, BDI, STAI-T, and pain intensity. The Persian version of the PASS-20 showed acceptable psychometric properties for the assessment of pain-related anxiety in Persian-speaking patients with chronic LBP. 3.

  14. Toward the Reliable Diagnosis of DSM-5 Premenstrual Dysphoric Disorder: The Carolina Premenstrual Assessment Scoring System (C-PASS)

    PubMed Central

    Eisenlohr-Moul, Tory A.; Girdler, Susan S.; Schmalenberger, Katja M.; Dawson, Danyelle N.; Surana, Pallavi; Johnson, Jacqueline L.; Rubinow, David R.

    2016-01-01

    Objective Despite evidence for the validity of premenstrual dysphoric disorder (PMDD) and its recent inclusion in DSM-5, variable diagnostic practices compromise the construct validity of the diagnosis and threaten the clarity of efforts to understand and treat its underlying pathophysiology. In an effort to hasten and streamline the translation of the new DSM-5 criteria for PMDD into terms compatible with existing research practices, we present the development and initial validation of the Carolina Premenstrual Assessment Scoring System (C-PASS). The C-PASS is a standardized scoring system for making DSM-5 PMDD diagnoses using 2 or more menstrual cycles of daily symptom ratings using the Daily Record of Severity of Problems (DRSP). Method Two hundred women recruited for retrospectively-reported premenstrual emotional symptoms provided 2–4 menstrual cycles of daily symptom ratings on the DRSP. Diagnoses were made by expert clinician and the C-PASS. Results Agreement of C-PASS diagnosis with expert clinical diagnosis was excellent; overall correct classification by the C-PASS was estimated at 98%. Consistent with previous evidence, retrospective reports of premenstrual symptom increases were a poor predictor of prospective C-PASS diagnosis. Conclusions The C-PASS (available as a worksheet, Excel macro, and SAS macro) is a reliable and valid companion protocol to the DRSP that standardizes and streamlines the complex, multilevel diagnosis of DSM-5 PMDD. Consistent use of this robust diagnostic method would result in more clearly-defined, homogeneous samples of women with PMDD, thereby improving the clarity of studies seeking to characterize or treat the underlying pathophysiology of the disorder. PMID:27523500

  15. Development of SiC Nanoparticles and Second Phases Synergistically Reinforced Mg-Based Composites Processed by Multi-Pass Forging with Varying Temperatures

    PubMed Central

    Nie, Kaibo; Guo, Yachao; Deng, Kunkun; Wang, Xiaojun; Wu, Kun

    2018-01-01

    In this study, SiC nanoparticles were added into matrix alloy through a combination of semisolid stirring and ultrasonic vibration while dynamic precipitation of second phases was obtained through multi-pass forging with varying temperatures. During single-pass forging of the present composite, as the deformation temperature increased, the extent of recrystallization increased, and grains were refined due to the inhibition effect of the increasing amount of dispersed SiC nanoparticles. A small amount of twins within the SiC nanoparticle dense zone could be found while the precipitated phases of Mg17Al12 in long strips and deformation bands with high density dislocations were formed in the particle sparse zone after single-pass forging at 350 °C. This indicated that the particle sparse zone was mainly deformed by dislocation slip while the nanoparticle dense zone may have been deformed by twinning. The yield strength and ultimate tensile strength of the composites were gradually enhanced through increasing the single-pass forging temperature from 300 °C to 400 °C, which demonstrated that initial high forging temperature contributed to the improvement of the mechanical properties. During multi-pass forging with varying temperatures, the grain size of the composite was gradually decreased while the grain size distribution tended to be uniform with reducing the deformation temperature and extending the forging passes. In addition, the amount of precipitated second phases was significantly increased compared with that after multi-pass forging under a constant temperature. The improvement in the yield strength of the developed composite was related to grain refinement strengthening and Orowan strengthening resulting from synergistical effect of the externally applied SiC nanoparticles and internally precipitated second phases. PMID:29342883

  16. Development of SiC Nanoparticles and Second Phases Synergistically Reinforced Mg-Based Composites Processed by Multi-Pass Forging with Varying Temperatures.

    PubMed

    Nie, Kaibo; Guo, Yachao; Deng, Kunkun; Wang, Xiaojun; Wu, Kun

    2018-01-13

    In this study, SiC nanoparticles were added into matrix alloy through a combination of semisolid stirring and ultrasonic vibration while dynamic precipitation of second phases was obtained through multi-pass forging with varying temperatures. During single-pass forging of the present composite, as the deformation temperature increased, the extent of recrystallization increased, and grains were refined due to the inhibition effect of the increasing amount of dispersed SiC nanoparticles. A small amount of twins within the SiC nanoparticle dense zone could be found while the precipitated phases of Mg 17 Al 12 in long strips and deformation bands with high density dislocations were formed in the particle sparse zone after single-pass forging at 350 °C. This indicated that the particle sparse zone was mainly deformed by dislocation slip while the nanoparticle dense zone may have been deformed by twinning. The yield strength and ultimate tensile strength of the composites were gradually enhanced through increasing the single-pass forging temperature from 300 °C to 400 °C, which demonstrated that initial high forging temperature contributed to the improvement of the mechanical properties. During multi-pass forging with varying temperatures, the grain size of the composite was gradually decreased while the grain size distribution tended to be uniform with reducing the deformation temperature and extending the forging passes. In addition, the amount of precipitated second phases was significantly increased compared with that after multi-pass forging under a constant temperature. The improvement in the yield strength of the developed composite was related to grain refinement strengthening and Orowan strengthening resulting from synergistical effect of the externally applied SiC nanoparticles and internally precipitated second phases.

  17. [Impact of passing items above the ceiling on the assessment results of Peabody developmental motor scales].

    PubMed

    Zhao, Gai; Bian, Yang; Li, Ming

    2013-12-18

    To analyze the impact of passing items above the roof level in the gross motor subtest of Peabody development motor scales (PDMS-2) on its assessment results. In the subtests of PDMS-2, 124 children from 1.2 to 71 months were administered. Except for the original scoring method, a new scoring method which includes passing items above the ceiling were developed. The standard scores and quotients of the two scoring methods were compared using the independent-samples t test. Only one child could pass the items above the ceiling in the stationary subtest, 19 children in the locomotion subtest, and 17 children in the visual-motor integration subtest. When the scores of these passing items were included in the raw scores, the total raw scores got the added points of 1-12, the standard scores added 0-1 points and the motor quotients added 0-3 points. The diagnostic classification was changed only in two children. There was no significant difference between those two methods about motor quotients or standard scores in the specific subtest (P>0.05). The passing items above a ceiling of PDMS-2 isn't a rare situation. It usually takes place in the locomotion subtest and visual-motor integration subtest. Including these passing items into the scoring system will not make significant difference in the standard scores of the subtests or the developmental motor quotients (DMQ), which supports the original setting of a ceiling established by upassing 3 items in a row. However, putting the passing items above the ceiling into the raw score will improve tracking of children's developmental trajectory and intervention effects.

  18. U-Groove aluminum weld strength improvement

    NASA Technical Reports Server (NTRS)

    Verderaime, V.; Vaughan, R.

    1996-01-01

    Though butt-welds are among the most preferred joining methods in aerostructures, their strength dependence on inelastic mechanics is generally the least understood. This study investigated experimental strain distributions across a thick aluminum U-grooved weld and identified two weld process considerations for improving the multipass weld strength. The extreme thermal expansion and contraction gradient of the fusion heat input across the groove tab thickness produces severe peaking, which induces bending under uniaxial loading. The filler strain-hardening decreased with increasing filler pass sequence, producing the weakest welds on the last pass side. Current welding schedules unknowingly compound these effects which reduce the weld strength. A depeaking index model was developed to select filler pass thicknesses, pass numbers, and sequences to improve depeaking in the welding process. The intent is to combine the strongest weld pass side with the peaking induced bending tension to provide a more uniform stress and stronger weld under axial tensile loading.

  19. Numerical simulation of terahertz transmission of bilayer metallic meshes with different thickness of substrates

    NASA Astrophysics Data System (ADS)

    Zhang, Gaohui; Zhao, Guozhong; Zhang, Shengbo

    2012-12-01

    The terahertz transmission characteristics of bilayer metallic meshes are studied based on the finite difference time domain method. The bilayer well-shaped grid, the array of complementary square metallic pill and the cross wire-hole array were investigated. The results show that the bilayer well-shaped grid achieves a high-pass of filter function, while the bilayer array of complementary square metallic pill achieves a low-pass of filter function, the bilayer cross wire-hole array achieves a band-pass of filter function. Between two metallic microstructures, the medium need to be deposited. Obviously, medium thicknesses have an influence on the terahertz transmission characteristics of metallic microstructures. Simulation results show that with increasing the thicknesses of the medium the cut-off frequency of high-pass filter and low-pass filter move to low frequency. But the bilayer cross wire-hole array possesses two transmission peaks which display competition effect.

  20. An error analysis of the recovery capability of the relative sea-surface profile over the Puerto Rican trench from multi-station and ship tracking of GEOS-2

    NASA Technical Reports Server (NTRS)

    Stanley, H. R.; Martin, C. F.; Roy, N. A.; Vetter, J. R.

    1971-01-01

    Error analyses were performed to examine the height error in a relative sea-surface profile as determined by a combination of land-based multistation C-band radars and optical lasers and one ship-based radar tracking the GEOS 2 satellite. It was shown that two relative profiles can be obtained: one using available south-to-north passes of the satellite and one using available north-to-south type passes. An analysis of multi-station tracking capability determined that only Antigua and Grand Turk radars are required to provide satisfactory orbits for south-to-north type satellite passes, while a combination of Merritt Island, Bermuda, and Wallops radars provide secondary orbits for north-to-south passes. Analysis of ship tracking capabilities shows that high elevation single pass range-only solutions are necessary to give only moderate sensitivity to systematic error effects.

  1. Passing particle toroidal precession induced by electric field in a tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andreev, V. V.; Ilgisonis, V. I.; Sorokina, E. A.

    2013-12-15

    Characteristics of a rotation of passing particles in a tokamak with radial electric field are calculated. The expression for time-averaged toroidal velocity of the passing particle induced by the electric field is derived. The electric-field-induced additive to the toroidal velocity of the passing particle appears to be much smaller than the velocity of the electric drift calculated for the poloidal magnetic field typical for the trapped particle. This quantity can even have the different sign depending on the azimuthal position of the particle starting point. The unified approach for the calculation of the bounce period and of the time-averaged toroidalmore » velocity of both trapped and passing particles in the whole volume of plasma column is presented. The results are obtained analytically and are confirmed by 3D numerical calculations of the trajectories of charged particles.« less

  2. High peak-power kilohertz laser system employing single-stage multi-pass amplification

    DOEpatents

    Shan, Bing; Wang, Chun; Chang, Zenghu

    2006-05-23

    The present invention describes a technique for achieving high peak power output in a laser employing single-stage, multi-pass amplification. High gain is achieved by employing a very small "seed" beam diameter in gain medium, and maintaining the small beam diameter for multiple high-gain pre-amplification passes through a pumped gain medium, then leading the beam out of the amplifier cavity, changing the beam diameter and sending it back to the amplifier cavity for additional, high-power amplification passes through the gain medium. In these power amplification passes, the beam diameter in gain medium is increased and carefully matched to the pump laser's beam diameter for high efficiency extraction of energy from the pumped gain medium. A method of "grooming" the beam by means of a far-field spatial filter in the process of changing the beam size within the single-stage amplifier is also described.

  3. Assessment of right ventricular function with nonimaging first pass ventriculography and comparison of results with gamma camera studies.

    PubMed

    Zhang, Z; Liu, X J; Liu, Y Z; Lu, P; Crawley, J C; Lahiri, A

    1990-08-01

    A new technique has been developed for measuring right ventricular function by nonimaging first pass ventriculography. The right ventricular ejection fraction (RVEF) obtained by non-imaging first pass ventriculography was compared with that obtained by gamma camera first pass and equilibrium ventriculography. The data has demonstrated that the correlation of RVEFs obtained by the nonimaging nuclear cardiac probe and by gamma camera first pass ventriculography in 15 subjects was comparable (r = 0.93). There was also a good correlation between RVEFs obtained by the nonimaging nuclear probe and by equilibrium gated blood pool studies in 33 subjects (r = 0.89). RVEF was significantly reduced in 15 patients with right ventricular and/or inferior myocardial infarction compared to normal subjects (28 +/- 9% v. 45 +/- 9%). The data suggests that nonimaging probes may be used for assessing right ventricular function accurately.

  4. Short-term absence from industry: II Temporal variation and inter-association with other recorded factors

    PubMed Central

    Froggatt, P.

    1970-01-01

    Froggatt, P. (1970).Brit. J. industr. Med.,27, 211-224. Short-term absence from industry. II. Temporal variation and inter-association with other recorded factors. This paper (a) extends the previous analysis (Froggatt, 1970b) of short-term absence from work among groups of male and female industrial personnel and clerks in government service, and (b) studies other recorded variables, particularly lateness, long-term sickness absence, and passes from work both `medical' and `works'. Multiple regression shows one-day absences to be generally associated with two-day absences, lateness, and medical passes but independent of works passes and long-term sickness absence; and two-day absences to be generally associated with one-day absences and long-term sickness absence but not with lateness or passes from work. Higher order correlations show lateness and works passes, medical passes and works passes, and lateness and age to be (weakly) associated, the last negatively. Irrespective of season, one-day absences were consistently most prevalent on Monday and least so on Friday, with a subsidiary peak for the male groups on Wednesday; two-day absences - as measured by the day each absence starts - were consistently most prevalent on Monday and least so on Thursday (Friday was omitted) and during the summer months. Medical passes were generally independent of the day of the week and the period of the year; lateness was greatest on Friday and during the winter, though the increase was slight; but works passes were relatively prevalent on Friday. Correlation and regression show the association between numbers of one-day absences taken in two periods of time (each one year) to be marked (r = 0·5 to 0·7), unaffected by transforming to normal functions, and explicable on a linear hypothesis, but the value of r to increase as the periods of time increase and to decrease as the interval between the periods of time lengthens. Similar analyses for two-day absences show r = 0·25 to 0·55, acceptance of a linear hypothesis, and a suggestion that the value of r may increase as the periods of time increase and as the interval between them shortens. More limited examination shows corresponding values of r (for contiguous years) to be of the order 0·25 for medical passes, 0·60 for works passes, but > 0·80 for lateness. Values of r between each of these factors in turn for all possible pairs of days of the week are reasonably consistent and show r of the order 0·35 for one-day absences, 0·25 for medical passes, 0·40 for works passes, and 0·80 for lateness (values for two-day absences are irregular and in the range 0 to 0·4). The consistency of lateness experience over days and years is very marked, the correlations being among the highest recorded for any event involving human behaviour. The importance and application of the findings are briefly discussed; detailed consideration is reserved for the third and last paper. PMID:5448119

  5. A Short Note on the Relationship between Pass Rate and Multiple Attempts

    ERIC Educational Resources Information Center

    Cheng, Ying; Liu, Cheng

    2016-01-01

    For a certification, licensure, or placement exam, allowing examinees to take multiple attempts at the test could effectively change the pass rate. Change in the pass rate can occur without any change in the underlying latent trait, and can be an artifact of multiple attempts and imperfect reliability of the test. By deriving formulae to compute…

  6. 7 CFR 868.315 - Special grades and special grade requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... milled rice which has been crushed or granulated so that 95.0 percent or more will pass through a 5 sieve, 70.0 percent or more will pass through a 4 sieve, and not more than 15.0 percent will pass through a 21/2 sieve. (c) Parboiled milled rice. Parboiled milled rice shall be milled rice in which the starch...

  7. 7 CFR 868.315 - Special grades and special grade requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... milled rice which has been crushed or granulated so that 95.0 percent or more will pass through a 5 sieve, 70.0 percent or more will pass through a 4 sieve, and not more than 15.0 percent will pass through a 21/2 sieve. (c) Parboiled milled rice. Parboiled milled rice shall be milled rice in which the starch...

  8. 7 CFR 868.315 - Special grades and special grade requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... milled rice which has been crushed or granulated so that 95.0 percent or more will pass through a 5 sieve, 70.0 percent or more will pass through a 4 sieve, and not more than 15.0 percent will pass through a 21/2 sieve. (c) Parboiled milled rice. Parboiled milled rice shall be milled rice in which the starch...

  9. Wave and Beach Processes Modeling for Sabine Pass to Galveston Bay, Texas, Shoreline Erosion Feasibility Study

    DTIC Science & Technology

    2007-08-01

    local wind field , led to the development of an appropriate alternative procedure which produced GENESIS results in agreement with observations...River field site wave data. ........................................................................................................53 Table 17...been abandoned since 1989 due to shoreline erosion. From east to west, the inlets in the study area include Sabine Pass, Rollover Pass near the

  10. 77 FR 12094 - Self-Regulatory Organizations; NASDAQ OMX BX, Inc.; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ...-BX-2011-073). \\4\\ Id. at 80998. The Exchange now proposes a pass-through reduction in the fees for.... The Exchange is passing along the entire savings of the reduction in fees to the subscribers of the... passing on reduced costs to members that opt to receive the connectivity options in question. \\8\\ See...

  11. Respectful Alignment of Programs as a Possible Factor in Remedial Writers' Pass Rates

    ERIC Educational Resources Information Center

    McDonald, Mary

    2017-01-01

    For over four years, students enrolled in remedial writing classes who attended eight writing center tutorials directly linked to their assignments had an average pass rate of 95.6 percent, whereas students who did not attend any writing center tutorials had an average pass rate of 39.4 percent. These correlations are just that--correlations that…

  12. Instantaneous Velocity Using Photogate Timers

    ERIC Educational Resources Information Center

    Wolbeck, John

    2010-01-01

    Photogate timers are commonly used in physics laboratories to determine the velocity of a passing object. In this application a card attached to a moving object breaks the beam of the photogate timer providing the time for the card to pass. The length L of the passing card can then be divided by this time to yield the average velocity (or speed)…

  13. 33 CFR 165.812 - Security Zones; Lower Mississippi River, Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans, LA. (a) Location. Within the Lower Mississippi River and Southwest Pass, moving security zones are established around all cruise ships between the... encompass all waters within 500 yards of a cruise ship. These zones remain in effect during the entire...

  14. 33 CFR 165.812 - Security Zones; Lower Mississippi River, Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans, LA. (a) Location. Within the Lower Mississippi River and Southwest Pass, moving security zones are established around all cruise ships between the... encompass all waters within 500 yards of a cruise ship. These zones remain in effect during the entire...

  15. 33 CFR 165.812 - Security Zones; Lower Mississippi River, Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans, LA. (a) Location. Within the Lower Mississippi River and Southwest Pass, moving security zones are established around all cruise ships between the... encompass all waters within 500 yards of a cruise ship. These zones remain in effect during the entire...

  16. 33 CFR 165.812 - Security Zones; Lower Mississippi River, Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans, LA. (a) Location. Within the Lower Mississippi River and Southwest Pass, moving security zones are established around all cruise ships between the... encompass all waters within 500 yards of a cruise ship. These zones remain in effect during the entire...

  17. 77 FR 50198 - Self-Regulatory Organizations; The Fixed Income Clearing Corporation; Notice of Filing Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-20

    ... Time at Which the Mortgage-Backed Securities Division Runs Its Daily Morning Pass August 14, 2012... Division (``MBSD'') runs its first processing pass of the day from 2 p.m. to 4 p.m. Eastern Standard Time... MBSD intends to move the time at which it runs its first processing pass of the day (historically...

  18. Low Temperature Cure Powder Coatings

    DTIC Science & Technology

    2013-05-01

    operations Minimize worker exposure to VOCs, HAPs, and hexavalent chrome Passed objective AF Engr Qual Plan = Air Force Engineer Quality Plan MIL-PRF...Inconclusive • Inconclusive • Not applicable (N/A) • Passed criteria Reduction of hexavalent chromium use • Passed objective Reduction of hazardous...compliance. The implementation of the OSHA Final Rule designating the permissible exposure limit (PEL) for hexavalent chromium is a significant

  19. Personal Academic Strategies for Success (PASS) Tool Administrator’s User Manual

    DTIC Science & Technology

    2013-12-01

    Personal Academic Strategies for Success (PASS) Tool Administrator’s User Manual by Jim H. Hewson, Valerie J. Rice, and Petra Alfred ARL...SR-275 December 2013 Personal Academic Strategies for Success (PASS) Tool Administrator’s User Manual Jim H. Hewson Career Management...Associates ( CMA ) Valerie J. Rice and Petra Alfred Human Research and Engineering Directorate, ARL

  20. Optical gas monitor

    DOEpatents

    Wu, Sheng; Deev, Andrei; Palm, Steve L.; Tang, Yongchun; Goddard, William A.

    2010-11-30

    A frequency modulated spectroscopy system, including a photo-detector, a band-pass filter to filter the output of the photo-detector, and a rectifier to demodulate. The band-pass filter has a relatively high Q factor. With the high Q factor band-pass filter and rectifier, a reference sinusoid is not required for demodulation, resulting in phase-insensitive spectroscopy. Other embodiments are described and claimed.

  1. Staffing Subsidies and the Quality of Care in Nursing Homes

    PubMed Central

    Foster, Andrew D.; Lee, Yong Suk

    2015-01-01

    Concerns about the quality of state-financed nursing home care has led to the wide-scale adoption by states of pass-through subsidies, in which Medicaid reimbursement rates are directly tied to staffing expenditure. We examine the effects of Medicaid pass-through on nursing home staffing and quality of care by adapting a two-step FGLS method that addresses clustering and state-level temporal autocorrelation. We find that pass-through subsidies increases staffing by about 1% on average and 2.7% in nursing homes with a low share of Medicaid patients. Furthermore, pass-through subsidies reduce the incidences of pressure ulcer worsening by about 0.9%. PMID:25814437

  2. The Effect of Multi-pass Equal-Channel Angular Pressing (ECAP) for Consolidation of Aluminum-Nano Alumina Composite Powder on Wear Resistance

    NASA Astrophysics Data System (ADS)

    Derakhshandeh-Haghighi, Reza; Jenabali Jahromi, Seyed Ahmad

    2016-02-01

    The wear behavior of aluminum matrix composite powder with varying concentration of nano alumina particles, which was consolidated by equal-channel angular pressing (ECAP) at different passes, was determined by applying, 10 and 46 N loads, using a pin-on-disk machine. Optical and electronic microscopy, EDX analysis, and hardness measurement were performed in order to characterize the worn samples. The relative density of the samples after each pass of ECAP was determined using Archimedes principle. Within the studied range of loads, the wear loss decreased by increasing the number of ECAP passes.

  3. By-Pass Diode Temperature Tests of a Solar Array Coupon under Space Thermal Environment Conditions

    NASA Technical Reports Server (NTRS)

    Wright, Kenneth H.; Schneider, Todd A.; Vaughn, Jason A.; Hoang, Bao; Wong, Frankie; Wu, Gordon

    2016-01-01

    By-Pass diodes are a key design feature of solar arrays and system design must be robust against local heating, especially with implementation of larger solar cells. By-Pass diode testing was performed to aid thermal model development for use in future array designs that utilize larger cell sizes that result in higher string currents. Testing was performed on a 56-cell Advanced Triple Junction solar array coupon provided by SSL. Test conditions were vacuum with cold array backside using discrete by-pass diode current steps of 0.25 A ranging from 0 A to 2.0 A.

  4. On the Performance of the Martin Digital Filter for High- and Low-pass Applications

    NASA Technical Reports Server (NTRS)

    Mcclain, C. R.

    1979-01-01

    A nonrecursive numerical filter is described in which the weighting sequence is optimized by minimizing the excursion from the ideal rectangular filter in a least squares sense over the entire domain of normalized frequency. Additional corrections to the weights in order to reduce overshoot oscillations (Gibbs phenomenon) and to insure unity gain at zero frequency for the low pass filter are incorporated. The filter is characterized by a zero phase shift for all frequencies (due to a symmetric weighting sequence), a finite memory and stability, and it may readily be transformed to a high pass filter. Equations for the filter weights and the frequency response function are presented, and applications to high and low pass filtering are examined. A discussion of optimization of high pass filter parameters for a rather stringent response requirement is given in an application to the removal of aircraft low frequency oscillations superimposed on remotely sensed ocean surface profiles. Several frequency response functions are displayed, both in normalized frequency space and in period space. A comparison of the performance of the Martin filter with some other commonly used low pass digital filters is provided in an application to oceanographic data.

  5. State legislation to improve employee wellness.

    PubMed

    Lankford, Tina; Kruger, Judy; Bauer, Deborah

    2009-01-01

    Categorize and describe the content and status of state legislation of worksite wellness. State worksite wellness legislation was compiled from the Centers for Disease Control's Division of Nutrition, Physical Activity and Obesity State Legislative Database (http://apps.nccd.cdc.gov/DNPALeg/index.asp) and from LexisNexis (http://www.lexisnexis. com). Key word searches were used to gather worksite wellness legislation (2001-2006), with the exception of resolutions and those bills not pertaining to general employee wellness. Legislation was individually examined, categorized, and analyzed for content and status. The four categories of state legislation that appeared to be most common were tax credits (n = 34; 0 passed), wellness policies and programs (n = 21; 4 passed), alternative transportation (n = 18; 4 passed), and health insurance (n = 14; 3 passed). During 2001 to 2006, seven of 27 states enacted worksite wellness bills. In the three categories in which bills passed (wellness policies and programs, alternative transportation, and health insurance), 19% to 22% were enacted. This proportion, similar to other health promotions bills, indicates that worksite health promotion legislation passed as favorably as other health promotion topics. Further, the language in the bills did not recommend a specific standard for employee health, such as that in the national Healthy People 2010 objectives.

  6. Linear fixed-field multipass arcs for recirculating linear accelerators

    DOE PAGES

    Morozov, V. S.; Bogacz, S. A.; Roblin, Y. R.; ...

    2012-06-14

    Recirculating Linear Accelerators (RLA's) provide a compact and efficient way of accelerating particle beams to medium and high energies by reusing the same linac for multiple passes. In the conventional scheme, after each pass, the different energy beams coming out of the linac are separated and directed into appropriate arcs for recirculation, with each pass requiring a separate fixed-energy arc. In this paper we present a concept of an RLA return arc based on linear combined-function magnets, in which two and potentially more consecutive passes with very different energies are transported through the same string of magnets. By adjusting themore » dipole and quadrupole components of the constituting linear combined-function magnets, the arc is designed to be achromatic and to have zero initial and final reference orbit offsets for all transported beam energies. We demonstrate the concept by developing a design for a droplet-shaped return arc for a dog-bone RLA capable of transporting two beam passes with momenta different by a factor of two. Finally, we present the results of tracking simulations of the two passes and lay out the path to end-to-end design and simulation of a complete dog-bone RLA.« less

  7. Laboratory septic tank performance response to electrolytic stimulation.

    PubMed

    Zaveri, Rahul M; Flora, Joseph R V

    2002-11-01

    This research investigated the effects of electrolytic stimulation on the performance of two laboratory-scale septic tanks. The tanks were fed a synthetic solution that included cellulose, peptone trypticase, beef extract, and urea. After a baseline period with no passed current, currents ranging from 100 to 500 mA were passed through the electrodes. The chemical oxygen demand (COD) removal efficiency from the tanks improved when a current was passed, with higher removal efficiencies observed at higher levels of passed current. Hydrolytic reactions resulted in ammonia and phosphate levels in the tanks that were higher than the influent. At currents > 300 mA, these hydrolytic reactions were suppressed, resulting in phosphate levels similar to the influent and ammonia levels lower than the influent because of the settling of ammonia-containing components of the feed solution. A slight increase in nitrate levels was observed when a current was passed, indicating minimal stimulation of nitrification activity. Abiotic studies confirmed that the COD can be removed via electrolysis and the removal was proportional to the passed current. Under the conditions of this study, the primary benefit of electrolytic stimulation of the septic tank is enhanced COD removal.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, H.L.; Spronsen, G. van; Klaus, E.H.

    A simulation model of the dynamics of a by-pass pig and related two-phase flow behavior along with field trials of the pig in a dry-gas pipeline have revealed significant gains in use of a by-pass pig in modifying gas and liquid production rates. The method can widen the possibility of applying two-phase flow pipeline transportation to cases in which separator or slug-catcher capacity is limited by practicality or cost. Pigging two-phase pipelines normally generates large liquid slug volumes in front of the pig. These require large separators or slug catchers. Using a high by-pass pig to disperse the liquid andmore » reduce the maximum liquid production rate before pig arrival has been investigated by Shell Exploration and Production companies. A simulation model of the dynamics of the pig and related two-phase flow behavior in the pipeline was used to predict the performance of by-pass pigs. Field trials in a dry-gas pipeline were carried out to provide friction data and to validate the model. The predicted mobility of the high by-pass pig in the pipeline and risers was verified and the beneficial effects due to the by-pass concept exceeded the prediction of the simplified model.« less

  9. Investigation of Microstructure and Mechanical Properties of ECAP-Processed AM Series Magnesium Alloy

    NASA Astrophysics Data System (ADS)

    Gopi, K. R.; Nayaka, H. Shivananda; Sahu, Sandeep

    2016-09-01

    Magnesium alloy Mg-Al-Mn (AM70) was processed by equal channel angular pressing (ECAP) at 275 °C for up to 4 passes in order to produce ultrafine-grained microstructure and improve its mechanical properties. ECAP-processed samples were characterized for microstructural analysis using optical microscopy, scanning electron microscopy, and transmission electron microscopy. Microstructural analysis showed that, with an increase in the number of ECAP passes, grains refined and grain size reduced from an average of 45 to 1 µm. Electron backscatter diffraction analysis showed the transition from low angle grain boundaries to high angle grain boundaries in ECAP 4 pass sample as compared to as-cast sample. The strength and hardness values an showed increasing trend for the initial 2 passes of ECAP processing and then started decreasing with further increase in the number of ECAP passes, even though the grain size continued to decrease in all the successive ECAP passes. However, the strength and hardness values still remained quite high when compared to the initial condition. This behavior was found to be correlated with texture modification in the material as a result of ECAP processing.

  10. SU-E-T-133: Assessing IMRT Treatment Delivery Accuracy and Consistency On a Varian TrueBeam Using the SunNuclear PerFraction EPID Dosimetry Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dieterich, S; Trestrail, E; Holt, R

    2015-06-15

    Purpose: To assess if the TrueBeam HD120 collimator is delivering small IMRT fields accurately and consistently throughout the course of treatment using the SunNuclear PerFraction software. Methods: 7-field IMRT plans for 8 canine patients who passed IMRT QA using SunNuclear Mapcheck DQA were selected for this study. The animals were setup using CBCT image guidance. The EPID fluence maps were captured for each treatment field and each treatment fraction, with the first fraction EPID data serving as the baseline for comparison. The Sun Nuclear PerFraction Software was used to compare the EPID data for subsequent fractions using a Gamma (3%/3mm)more » pass rate of 90%. To simulate requirements for SRS, the data was reanalyzed using a Gamma (3%/1mm) pass rate of 90%. Low-dose, low- and high gradient thresholds were used to focus the analysis on clinically relevant parts of the dose distribution. Results: Not all fractions could be analyzed, because during some of the treatment courses the DICOM tags in the EPID images intermittently change from CU to US (unspecified), which would indicate a temporary loss of EPID calibration. This technical issue is still being investigated. For the remaining fractions, the vast majority (7/8 of patients, 95% of fractions, and 96.6% of fields) are passing the less stringent Gamma criteria. The more stringent Gamma criteria caused a drop in pass rate (90 % of fractions, 84% of fields). For the patient with the lowest pass rate, wet towel bolus was used. Another patient with low pass rates experienced masseter muscle wasting. Conclusion: EPID dosimetry using the PerFraction software demonstrated that the majority of fields passed a Gamma (3%/3mm) for IMRT treatments delivered with a TrueBeam HD120 MLC. Pass rates dropped for a DTA of 1mm to model SRS tolerances. PerFraction pass rates can flag missing bolus or internal shields. Sanjeev Saini is an employee of Sun Nuclear Corporation. For this study, a pre-release version of PerFRACTION 1.1 software from Sun Nuclear Corporation was used.« less

  11. Quality of hip and knee osteoarthritis management in primary health care in a Norwegian county: a cross-sectional survey.

    PubMed

    Grønhaug, Gudmund; Østerås, Nina; Hagen, Kåre Birger

    2014-11-25

    Osteoarthritis (OA) is one of the most common causes of pain and disability in the adult population. Several studies have documented discordance between general practioners (GP) practice and management recommendations, but there is limited published information about patient reported experience of quality of care. The primary aim of this study was to assess the patient perceived quality of OA management in primary health care. Secondly, we wanted to explore the factors associated with the perceived quality of OA care. A cross-sectional survey in six general practices in the county of Nord-Trøndelag in Norway, patients with radiologically diagnosed OA, according to ICPC codes L89, L90 or L91 or clinical signs and symptoms corresponding to OA in the hip or knee and patient-reported quality of OA care on the 17-item OsteoArthritis Quality Indicator questionnaire (OA-QI). OA-QI summary pass rates were calculated, in which the numerator represents the number with indicators passed and the denominator represents the total number of eligible persons. Associations with summary pass rates were explored with demographic, disease related and health care related factors as independent variables. A total of 119 patients were included (response rate 42%). The median summary QI pass rate for all 17 QIs was 47% (Inter Quartile Range 33-65%), but there were large variation between the different items. The referral for weight reduction had the lowest pass rate (8%), whereas the highest pass rate was having received information about the importance of physical activity and exercise (84%). The median summary QI pass rates for both non-pharmacological- (QIs 1-11) and pharmacological (QIs 13-16) treatments were 50% (IQR 25-75). In bivariate regression analyses, only overall treatment satisfaction was significantly associated with QI pass rate (p = 0.001), with unstandardized beta = 6.1 (95% CI 2.7 to 9.5), i.e. a one-point increase on the five-point satisfaction scale was associated with a 6% increase in pass rate. Considering that the median summary QI pass rate was 47%, there might be room for improvement in OA care. Advice and the referral of OA patients in need of weight reduction seem to have the greatest potential for improvement.

  12. Correlation of histological findings of single session Er:YAG skin fractional resurfacing with various passes and energies and the possible clinical implications.

    PubMed

    Trelles, Mario A; Vélez, Mariano; Mordon, Serge

    2008-03-01

    Ablative fractional resurfacing shows promise for skin resurfacing and tightening and also to improve treatment of epidermal and dermal pigmentary disorders. This study aimed at determining any correlation between epidermal ablation and effects on the dermis when using an Er:YAG laser in ablative fractional resurfacing mode. Ten female subjects participated in the study, mean age 52 years, Skin phototypes: 1 Fitzpatrick type II; 8 type III and 1 type IV. The degree of wrinkles (Glogau scale II or III) was similar in all cases. The laser used was the Pixel Er:YAG system (Alma Lasertrade mark, Israel) which delivers the laser beam via a hand-piece equipped with a beam splitter to divide the 2,940 nm beam into various microbeams of 850 microm in diameter in an 11 mmx11 mm treatment area. Using a constant energy of 1,400 mJ/cm(2), on a test area of 4 cmx2 cm. Two, 4, 6, and 8 passes on the preauricular area of the face were evaluated immediately after treatment. In all cases, the handpiece was kept in the same position, and rotated slightly around its perpendicular axis between passes, then moved on to the next spot. Biopsies were performed and tissue samples were routinely processed and stained with hematoxylin and eosin (H&E). No patient reported any noticeable discomfort, even at 8 passes. The histological findings revealed that, independent of the degree of the wrinkles, more laser passes produced more ablative removal of the epidermis. Residual thermal damage (RTD) with 2 laser passes was not observed but with 4 and 6 passes increased thermal effects and vacuole formation in the epidermal cells were noticed. With 8 laser passes, total epidermal removal was seen together with frank RTD-related changes in the upper part of the papillary dermis. In this study, we have demonstrated that high density fractional Er:YAG laser energy in a single session with multiple passes targeted not only the skin surface with elimination of the epidermis, but could also achieve heat deposition in the upper dermis. When performing ablative fractional resurfacing with an Er:YAG laser, treatment of varying degrees of damage could be achieved by varying the number of passes. (c) 2008 Wiley-Liss, Inc.

  13. The effect of Medicaid wage pass-through programs on the wages of direct care workers.

    PubMed

    Baughman, Reagan A; Smith, Kristin

    2010-05-01

    Despite growing demand for nursing and home health care as the US population ages, compensation levels in the low-skill nursing labor market that provides the bulk of long-term care remain quite low. The challenge facing providers of long-term care is that Medicaid reimbursement rates for nursing home and home health care severely restrict the wage growth that is necessary to attract workers, resulting in high turnover and labor shortages. Almost half of US states have responded by enacting "pass-through" provisions in their Medicaid programs, channeling additional long-term care funding directly to compensation of lower-skill nursing workers. We test the effect of Medicaid wage pass-through programs on hourly wages for direct care workers. We estimate several specifications of wage models using employment data from the 1996 and 2001 panels of the Survey of Income and Program Participation for nursing, home health, and personal care aides. The effect of pass-through programs is identified by an indicator variable for states with programs; 20 states adopted pass-throughs during the sample period. Workers in states with pass-through programs earn as much as 12% more per hour than workers in other states after those programs are implemented. Medicaid wage pass-through programs appear to be a viable policy option for raising compensation levels of direct care workers, with an eye toward improving recruitment and retention in long-term care settings.

  14. [PASS neurocognitive dysfunction in attention deficit].

    PubMed

    Pérez-Alvarez, F; Timoneda-Gallart, C

    Attention deficit disorder shows both cognitive and behavioral patterns. To determine a particular PASS (planning, attention, successive and simultaneous) pattern in order to early diagnosis and remediation according to PASS theory. 80 patients were selected from the neuropediatric attendance, aged 6 to 12 years old, 55 boys and 25 girls. Inclusion criteria were inattention (80 cases) and inattention with hyperactive symptoms (40 cases) according to the Diagnostic and Statistical Manual (DSM-IV). Exclusion criteria were the criteria of phonologic awareness previously reported, considered useful to diagnose dyslexia. A control group of 300 individuals, aged 5 to 12 years old, was used, criteria above mentioned being controlled. DN:CAS (Das-Naglieri Cognitive Assessment System) battery, translated to native language, was given to assess PASS cognitive processes. Results were analyzed with cluster analysis and t-Student test. Statistical factor analysis of the control group had previously identified the four PASS processes: planning, attention, successive and simultaneous. The dendrogram of the cluster analysis discriminated three categories of attention deficit disorder: 1. The most frequent, with planning deficit; 2. Without planning deficit but with deficit in other processes, and 3. Just only a few cases, without cognitive processing deficit. Cognitive deficiency in terms of means of scores was statistically significant when compared to control group (p = 0.001). According to PASS pattern, planning deficiency is a relevant factor. Neurological planning is not exactly the same than neurological executive function. The behavioral pattern is mainly linked to planning deficiency, but also to other PASS processing deficits and even to no processing deficit.

  15. Late Quaternary history of contourite drifts and variations in Labrador Current flow, Flemish Pass, offshore eastern Canada

    NASA Astrophysics Data System (ADS)

    Marshall, Nicole R.; Piper, David J. W.; Saint-Ange, Francky; Campbell, D. Calvin

    2014-10-01

    Contourite drifts of alternating sand and mud, shaped by the Labrador Current, formed during the late Quaternary in Flemish Pass seaward of the Grand Banks of Newfoundland, Canada. The drifts preserve a record of Labrador Current flow variations through the last glacial maximum. A high-resolution seismic profile and a transect of four cores were collected across Beothuk drift on the southeast side of Flemish Pass. Downcore and lateral trends in grain size and sedimentation rate provide evidence that, between 16 and 13 ka, sediment was partitioned across Beothuk drift and the adjacent Flemish Pass floor by a strong current flow but, from 29 to 16 ka, sedimentation was more of a blanketing style, represented by draped reflections interpreted as being due to a weaker current. The data poorly resolve the low sedimentation rates since 13 ka, but the modern Labrador Current in Flemish Pass is the strongest it has been in at least the past 29 ka. Pre-29 ka current flow is interpreted based on reflection architecture in seismic profiles. A prominent drift on the southwestern side of Flemish Pass formed above a mid-Miocene erosion surface, but was buried by a mass-transport deposit after the penultimate glacial maximum and after drift deposition switched to eastern Flemish Pass. These findings illustrate the temporal complexity of drift sedimentation and provide the first detailed proxy for Labrador Current flow since the last glacial maximum.

  16. Role of the micro/macro structure of welds in crack nucleation and propagation in aerospace aluminum-lithium alloy

    NASA Technical Reports Server (NTRS)

    Talia, George E.

    1996-01-01

    Al-Li alloys offer the benefits of increased strength, elastic modulus and lower densities as compared to conventional aluminum alloys. Martin Marietta Laboratories has developed an Al-Li alloy designated 2195 which is designated for use in the cryogenic tanks of the space shuttle. The Variable Polarity Plasma Arc (VPPA) welding process is currently being used to produce these welds [1]. VPPA welding utilizes high temperature ionized gas (plasma) to transfer heat to the workpiece. An inert gas, such as Helium, is used to shield the active welding zone to prevent contamination of the molten base metal with surrounding reactive atmospheric gases. [1] In the Space Shuttle application, two passes of the arc are used to complete a butt-type weld. The pressure of the plasma stream is increased during the first pass to force the arc entirely through the material, a practice commonly referred to as keyholing. Molten metal forms on either side of the arc and surface tension draws this liquid together as the arc passes. 2319 Al alloy filler material may also be fed into the weld zone during this pass. During the second pass, the plasma stream pressure is reduced such that only partial penetration of the base material is obtained. Al 2319 filler material is added during this pass to yield a uniform, fully filled welded joint. This additional pass also acts to alter the grain structure of the weld zone to yield a higher strength joint.

  17. Factors Affecting Route Selection and Survival of Steelhead Kelts at Snake River Dams in 2012 and 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harnish, Ryan A.; Colotelo, Alison HA; Li, Xinya

    2014-12-01

    In 2012 and 2013, Pacific Northwest National Laboratory conducted a study that summarized the passage proportions and route-specific survival rates of steelhead kelts that passed through Federal Columbia River Power System (FCRPS) dams. To accomplish this, a total of 811 steelhead kelts were tagged with Juvenile Salmon Acoustic Telemetry System (JSATS) transmitters. Acoustic receivers, both autonomous and cabled, were deployed throughout the FCRPS to monitor the downstream movements of tagged-kelts. Kelts were also tagged with Passive Integrated Transponder tags to monitor passage through juvenile bypass systems and detect returning fish. The current study evaluated data collected in 2012 and 2013more » to identify individual, behavioral, environmental and dam operation variables that were related to passage and survival of steelhead kelts that passed through FCRPS dams. Bayesian model averaging of multivariable logistic regression models was used to identify the environmental, temporal, operational, individual, and behavioral variables that had the highest probability of influencing the route of passage and the route-specific survival probabilities for kelts that passed Lower Granite (LGR), Little Goose (LGS), and Lower Monumental (LMN) dams in 2012 and 2013. The posterior probabilities of the best models for predicting route of passage ranged from 0.106 for traditional spill at LMN to 0.720 for turbine passage at LGS. Generally, the behavior (depth and near-dam searching activity) of kelts in the forebay appeared to have the greatest influence on their route of passage. Shallower-migrating kelts had a higher probability of passing via the weir and deeper-migrating kelts had a higher probability of passing via the JBS and turbines than other routes. Kelts that displayed a higher level of near-dam searching activity had a higher probability of passing via the spillway weir and those that did less near-dam searching had a higher probability of passing via the JBS and turbines. The side of the river in which kelts approached the dam and dam operations also affected route of passage. Dam operations and the size and condition of kelts were found to have the greatest effect on route-specific survival probabilities for fish that passed via the spillway at LGS. That is, longer kelts and those in fair condition had a lower probability of survival for fish that passed via the spillway weir. The survival of spillway weir- and deep-spill passed kelts was positively correlated with the percent of the total discharge that passed through turbine unit 4. Too few kelts passed through the traditional spill, JBS, and turbine units to evaluate survival through these routes. The information gathered in this study describes Snake River steelhead kelt passage behavior, rates, and distributions through the FCRPS as well as provide information to biologists and engineers about the dam operations and abiotic conditions that are related to passage and survival of steelhead kelts.« less

  18. Older Children's Misunderstanding of Uncertain Belief after Passing the False Belief Test

    ERIC Educational Resources Information Center

    Zhang, Ting; Zheng, Xueru; Zhang, Li; Sha, Wenju; Deak, Gedeon; Li, Hong

    2010-01-01

    A four-location belief task was designed to examine children's understanding of another's uncertain belief after passing a false belief (FB) task. In Experiment 1, after passing the FB task, participants were asked what a puppet would do after he failed to find his toy at the falsely believed location. Most 4-year-olds and half of 6-year-olds…

  19. 26 CFR 1.53-3 - Separate rule for pass-through of jobs credit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 1 2013-04-01 2013-04-01 false Separate rule for pass-through of jobs credit. 1... INCOME TAXES Tax Surcharge § 1.53-3 Separate rule for pass-through of jobs credit. (a) In general. Under section 53(b), in the case of a new jobs credit or targeted jobs credit earned under section 44B by a...

  20. "We Were Told We're Not Teachers... It Gets Difficult to Draw the Line": Negotiating Roles in Peer-Assisted Study Sessions (PASS)

    ERIC Educational Resources Information Center

    Brown, Kim; Nairn, Karen; van der Meer, Jacques; Scott, Carole

    2014-01-01

    Peer learning models in pre-service teacher education are in the early stages of implementation. In this article, we evaluated a pilot Peer-Assisted Study Sessions (PASS) program that supplemented a course for pre-service teachers at one New Zealand university. PASS participants discussed experiences of the program, revealing tensions between what…

  1. North Texas Sediment Budget: Sabine Pass to San Luis Pass

    DTIC Science & Technology

    2006-09-01

    concrete units have been placed over sand-filled fabric tube . .......................................33 Figure 28. Sand-filled fabric tubes protecting...system UTM Zone 15, NAD 83 Longshore drift directions King (in preparation) Based on wave hindcast statistics and limited buoy data Rollover Pass...along with descriptions of the jetties and limited geographic coordinate data1 (Figure 18). The original velum or Mylar sheets from which the report

  2. Students with Specific Learning Disabilities Can Pass State Competency Exams: Systematic Strategy Instruction Makes a Difference

    ERIC Educational Resources Information Center

    Barry, Leasha M.; Moore, William E., IV

    2004-01-01

    Students with specific learning disabilities (SLD) are required to pass the same competency exams as students enrolled in general education in order to graduate to new grade levels and to earn a high school diploma. In this study, the authors taught students with SLD a self-directed organizational strategy designed to assist them in passing the…

  3. Evaluation of the Class Pass Intervention for Typically Developing Students with Hypothesized Escape-Motivated Disruptive Classroom Behavior

    ERIC Educational Resources Information Center

    Cook, Clayton R.; Collins, Tai; Dart, Evan; Vance, Michael J.; McIntosh, Kent; Grady, Erin A.; DeCano, Policarpio

    2014-01-01

    The aim of this study was to evaluate the Class Pass Intervention (CPI) as a secondary intervention for typically developing students with escape-motivated disruptive classroom behavior. The CPI consists of providing students with passes that they can use to appropriately request a break from an academic task to engage in a preferred activity for…

  4. 33 CFR 165.812 - Security Zones; Lower Mississippi River, Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... River, Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans, LA. 165.812 Section 165.812 Navigation..., Southwest Pass Sea Buoy to Mile Marker 96.0, New Orleans, LA. (a) Location. Within the Lower Mississippi... Lower Mississippi River mile marker 96.0 in New Orleans, Louisiana. These moving security zones...

  5. Passing the Torch by Passing on a Skill: Passing the Torch to the Next Generation is the Intrinsic Reward for Dedicated Technology Teachers

    ERIC Educational Resources Information Center

    Millson, David; Jerie, Branko

    2005-01-01

    Motivating students to master the basics in any field is a demanding task. In technical education, while the direct benefit--almost certain, well-paying employment--is obvious, the challenge is to keep students' interest high. Absent that, the technical workforce lacks skilled replenishment, and the possibility of being overtaken by competition…

  6. Laser Line Scan System for UXO Characterization

    DTIC Science & Technology

    2012-04-01

    they geometrically rectified. The Year 2 survey collected LLSS images from seven passes over two separate calibration strings and six passes over two...Microsoft DOS-based software tool. According to the side- by-side comparisons shown in Figure 9, the morphometrics were relatively equal between...survey. Note: The imagery in this figure is not presented at full resolution nor geometrically rectified. LLSS Targets, Pass One 1. Danforth

  7. 76 FR 13683 - Self-Regulatory Organizations; The Fixed Income Clearing Corporation; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... To Move the Time at Which It Runs Its Daily Morning Pass March 8, 2011. Pursuant to Section 19(b)(1... Backed Securities Division (``MBSD'') intends to move the time at which it runs its daily morning pass... notify participants that MBSD intends to move the time at which it runs its daily morning pass from 10:30...

  8. Standard Setting for Clinical Competence at Graduation from Medical School: A Comparison of Passing Scores across Five Medical Schools

    ERIC Educational Resources Information Center

    Boursicot, Katharine A. M.; Roberts, Trudie E.; Pell, Godfrey

    2006-01-01

    While Objective Structured Clinical Examinations (OSCEs) have become widely used to assess clinical competence at the end of undergraduate medical courses, the method of setting the passing score varies greatly, and there is no agreed best methodology. While there is an assumption that the passing standard at graduation is the same at all medical…

  9. SU-F-T-236: Comparison of Two IMRT/VMAT QA Systems Using Gamma Index Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dogan, N; Denissova, S

    2016-06-15

    Purpose: The goal of this study is to assess differences in the Gamma index pass rates when using two commercial QA systems and provide optimum Gamma index parameters for pre-treatment patient specific QA. Methods: Twenty-two VMAT cases that consisted of prostate, lung, head and neck, spine, brain and pancreas, were included in this study. The verification plans have been calculated using AcurosXB(V11) algorithm for different dose grids (1.5mm, 2.5mm, 3mm). The measurements were performed on TrueBeam(Varian) accelerator using both EPID(S1000) portal imager and ArcCheck(SunNuclearCorp) devices. Gamma index criteria variation of 3%/3mm, 2%/3mm, 2%/2mm and threshold (TH) doses of 5% tomore » 50% were used in analysis. Results: The differences in Gamma pass rates between two devices are not statistically significant for 3%/3mm, yielding pass rate higher than 95%. Increase of lower dose TH showed reduced pass rates for both devices. ArcCheck’s more pronounced effect can be attributed to higher contribution of lower dose region spread. As expected, tightening criteria to 2%/2mm (TH: 10%) decreased Gamma pass rates below 95%. Higher EPID (92%) pass rates compared to ArcCheck (86%) probably due to better spatial resolution. Portal Dosimetry results showed lower Gamma pass rates for composite plans compared to individual field pass rates. This may be due to the expansion in the analyzed region which includes pixels not included in the separate field analysis. Decreasing dose grid size from 2.5mm to 1.5mm did not show statistically significant (p<0.05) differences in Gamma pass rates for both QA devices. Conclusion: Overall, both system measurements agree well with calculated dose when using gamma index criteria of 3%/3mm for a variety of VMAT cases. Variability between two systems increases using different dose GRID, TH and tighter gamma criteria and must be carefully assessed prior to clinical use.« less

  10. A 9-year follow-up of a self-management group intervention for persistent neck pain in primary health care: a randomized controlled trial

    PubMed Central

    Gustavsson, Catharina; von Koch, Lena

    2017-01-01

    Background and objective In previous short-term and 2-year follow-ups, a pain and stress self-management group intervention (PASS) had better effect on pain-related disability, self-efficacy, catastrophizing, and perceived pain control than individually administered physiotherapy (IAPT) for patients with persistent tension-type neck pain. Studies that have evaluated long-term effects of self-management approaches toward persistent neck pain are sparse. The objective of this study was to compare pain-related disability, self-efficacy for activities of daily living (ADL), catastrophizing, pain, pain control, use of analgesics, and health care utilization in people with persistent tension-type neck pain 9 years after they received the PASS or IAPT. Materials and methods Of 156 people (PASS, n = 77; IAPT, n = 79) originally included in a randomized controlled trial, 129 people (PASS, n = 63; IAPT, n = 66) were eligible and were approached for the 9-year follow-up. They were sent a self-assessment questionnaire, comprising the Neck Disability Index, the Self-Efficacy Scale, the Coping Strategies Questionnaire, and questions regarding pain, analgesics, and health care utilization. Mixed linear models for repeated measures analysis or generalized estimating equations were used to evaluate the differences between groups and within groups over time (baseline, previous follow-ups, and 9-year follow-up) and the interaction effect of “time by group”. Results Ninety-four participants (73%) responded (PASS, n = 48; IAPT, n = 46). At 9 years, PASS participants reported less pain-related disability, pain at worst, and analgesics usage, and a trend toward better self-efficacy compared to IAPT participants. There was a difference between groups in terms of change over time for disability, self-efficacy for ADL, catastrophizing, perceived pain control, and health care visits in favor of PASS. Analyses of simple main effects at 9 years showed that the PASS group had less disability (p = 0.006) and a trend toward better self-efficacy (p = 0.059) than the IAPT group. Conclusion The favorable effects on pain-related disability of PASS were sustained 9 years after the intervention. PMID:28115865

  11. Performance of a surface bypass structure to enhance juvenile steelhead passage and survival at Lower Granite Dam, Washington

    USGS Publications Warehouse

    Adams, Noah S.; Plumb, John M.; Perry, Russell W.; Rondorf, Dennis W.

    2014-01-01

    An integral part of efforts to recover stocks of Pacific salmon Oncorhynchus spp. and steelhead O. mykiss in Pacific Northwest rivers is to increase passage efficacy and survival of juveniles past hydroelectric dams. As part of this effort, we evaluated the efficacy of a prototype surface bypass structure, the removable spillway weir (RSW), installed in a spillbay at Lower Granite Dam, Washington, on the Snake River during 2002, 2003, 2005, and 2006. Radio-tagged juvenile steelhead were released upstream from the dam and their route of passage through the turbines, juvenile bypass, spillway, or RSW was recorded. The RSW was operated in an on-or-off condition and passed 3–13% of the total discharge at the dam when it was on. Poisson rate models were fit to the passage counts of hatchery- and natural-origin juvenile steelhead to predict the probability of fish passing the dam. Main-effect predictor variables were RSW operation, diel period, day of the year, proportion of flow passed by the spillway, and total discharge at the dam. The combined fish passage through the RSW and spillway was 55–85% during the day and 37–61% during the night. The proportion of steelhead passing through nonturbine routes was <88% when the RSW was off during the day and increased to >95% when the RSW was on during the day. The ratio of the proportion of steelhead passed to the proportion of water passing the RSW was from 6.3:1 to 10.0:1 during the day and from 2.7:1 to 5.2:1 during the night. Steelhead passing through the RSW exited the tailrace about 15 min faster than fish passing through the spillway. Mark–recapture single-release survival estimates for steelhead passing the RSW ranged from 0.95 to 1.00. The RSW appeared to be an effective bypass structure compared with other routes of fish passage at the dam.

  12. The Pancreatitis Activity Scoring System predicts clinical outcomes in acute pancreatitis: findings from a prospective cohort study.

    PubMed

    Buxbaum, James; Quezada, Michael; Chong, Bradford; Gupta, Nikhil; Yu, Chung Yao; Lane, Christianne; Da, Ben; Leung, Kenneth; Shulman, Ira; Pandol, Stephen; Wu, Bechien

    2018-05-01

    The Pancreatitis Activity Scoring System (PASS) has been derived by an international group of experts via a modified Delphi process. Our aim was to perform an external validation study to assess for concordance of the PASS score with high face validity clinical outcomes and determine specific meaningful thresholds to assist in application of this scoring system in a large prospectively ascertained cohort. We analyzed data from a prospective cohort study of consecutive patients admitted to the Los Angeles County Hospital between March 2015 and March 2017. Patients were identified using an emergency department paging system and electronic alert system. Comprehensive characterization included substance use history, pancreatitis etiology, biochemical profile, and detailed clinical course. We calculated the PASS score at admission, discharge, and at 12 h increments during the hospitalization. We performed several analyses to assess the relationship between the PASS score and outcomes at various points during hospitalization as well as following discharge. Using multivariable logistic regression analysis, we assessed the relationship between admission PASS score and risk of severe pancreatitis. PASS score performance was compared to established systems used to predict severe pancreatitis. Additional inpatient outcomes assessed included local complications, length of stay, development of systemic inflammatory response syndrome (SIRS), and intensive care unit (ICU) admission. We also assessed whether the PASS score at discharge was associated with early readmission (re-hospitalization for pancreatitis symptoms and complications within 30 days of discharge). A total of 439 patients were enrolled, their mean age was 42 (±15) years, and 53% were male. Admission PASS score >140 was associated with moderately severe and severe pancreatitis (OR 3.5 [95% CI 2.0, 6.3]), ICU admission (OR 4.9 [2.5, 9.4]), local complications (3.0 [1.6, 5.7]), and development of SIRS (OR 2.9 [1.8, 4.5]) as well as prolongation of hospitalization by a mean of 1.5 (1.3-1.7) days. For the prediction of moderately severe/severe pancreatitis, the PASS score (AUC = 0.71) was comparable to the more established Ranson's (AUC = 0.63), Glasgow (AUC = 0.72), Panc3 (AUC = 0.57), and HAPS (AUC = 0.54) scoring systems. Discharge PASS score >60 was associated with early readmission (OR 5.0 [2.4, 10.7]). The PASS score is associated with important clinical outcomes in acute pancreatitis. The ability of the score to forecast important clinical events at different points in the disease course suggests that it is a valid measure of activity in patients with acute pancreatitis.

  13. Skills and offensive tactics used in pick-up basketball games.

    PubMed

    Wang, Jianyu; Liu, Wenhao; Moffit, Jeffrey

    2009-10-01

    The purpose of this study was to describe skills and offensive tactics frequently used in pick-up basketball games. 65 participants were recruited from public basketball courts. An observational instrument was developed to analyze the performances of pick-up games. Participants' performances were videotaped and coded. Results indicated that the passing skills most frequently observed in the games were chest pass, overhead pass, and bounce pass. For dribbling, crossover dribble and change-of-pace dribble were frequently observed. Jump shot, set shot, and layup were also frequently used. The offensive tactics frequently used included drive, cut, and set screen. The study may be beneficial for helping young people prepare to play pick-up basketball games.

  14. MPF: A portable message passing facility for shared memory multiprocessors

    NASA Technical Reports Server (NTRS)

    Malony, Allen D.; Reed, Daniel A.; Mcguire, Patrick J.

    1987-01-01

    The design, implementation, and performance evaluation of a message passing facility (MPF) for shared memory multiprocessors are presented. The MPF is based on a message passing model conceptually similar to conversations. Participants (parallel processors) can enter or leave a conversation at any time. The message passing primitives for this model are implemented as a portable library of C function calls. The MPF is currently operational on a Sequent Balance 21000, and several parallel applications were developed and tested. Several simple benchmark programs are presented to establish interprocess communication performance for common patterns of interprocess communication. Finally, performance figures are presented for two parallel applications, linear systems solution, and iterative solution of partial differential equations.

  15. Final Inspection of Lactated Ringer’s Resuscitation Fluid, Intravenous Sodium Chloride Solution, and Sodium Chloride-Glucose Solution Used in the Deglycerolization of Human Red Cells Frozen With 40% W/V Glycerol, Produced by the Sterimatics EDM Reflups System and Stored for 8 Months to 2.3 Years.

    DTIC Science & Technology

    1994-09-08

    SHIP LR500 000218201816 07/28/94 P N N 25 8237 SHIP LR500 000218201905 07/30/94 P N N 26 8301 SHIP LR500 000218201910 07/30/94 P N N 27 7395 SHIP...24 25 8237 SHIP LR500 000218201905 07/30/94 P 561 512 PASS 537 500 PASS 24 26 8301 SHIP LR500 000218201910 07/30/94 P 562 513 PASS 538 501 PASS 24

  16. Investigation of tidal displacements of the Earth's surface by laser ranging to GEOS-3

    NASA Technical Reports Server (NTRS)

    Bower, D. R.; Halpenny, J.; Paul, M. K.; Lambert, A.

    1980-01-01

    An analysis of laser ranging data from three stations was carried out in an attempt to measure the geometric Earth tide. Two different approaches to the problem were investigated. The dynamic method computes pass to pass apparent movements in stations height relative to short arcs fitted to several passes of data from the same station by the program GEODYNE. The quasi-geometric method reduces the dependence on unmodelled satellite dynamics to a knowledge of only the radial position of the satellite by considering two station simultaneous ranging at the precise time that the satellite passes through the plane defined by two stations and the center of mass of the Earth.

  17. Interpretation of surface-water circulation, Aransas Pass, Texas, using Landsat imagery

    NASA Technical Reports Server (NTRS)

    Finley, R. J.; Baumgardner, R. W., Jr.

    1980-01-01

    The development of plumes of turbid surface water in the vicinity of Aransas Pass, Texas has been analyzed using Landsat imagery. The shape and extent of plumes present in the Gulf of Mexico is dependent on the wind regime and astronomical tide prior to and at the time of satellite overpass. The best developed plumes are evident when brisk northerly winds resuspend bay-bottom muds and flow through Aransas Pass is increased by wind stress. Seaward diversion of nearshore waters by the inlet jetties was also observed. A knowledge of surface-water circulation through Aransas Pass under various wind conditions is potentially valuable for monitoring suspended and surface pollutants

  18. Bathymetric survey of the nearshore from Belle Pass to Caminada Pass, Louisiana: methods and data report

    USGS Publications Warehouse

    DeWitt, Nancy T.; Flocks, James G.; Hansen, Mark; Kulp, Mark; Reynolds, B.J.

    2007-01-01

    The U.S. Geological Survey (USGS), in cooperation with the University of New Orleans (UNO) and the Louisiana Department of Natural Resources (LDNR), conducted a high-resolution, single-beam bathymetric survey along the Louisiana southern coastal zone from Belle Pass to Caminada Pass. The survey consisted of 483 line kilometers of data acquired in July and August of 2005. This report outlines the methodology and provides the data from the survey. Analysis of the data and comparison to a similar bathymetric survey completed in 1989 show significant loss of seafloor and shoreline retreat, which is consistent with previously published estimates of shoreline change in the study area.

  19. Efficiently passing messages in distributed spiking neural network simulation.

    PubMed

    Thibeault, Corey M; Minkovich, Kirill; O'Brien, Michael J; Harris, Frederick C; Srinivasa, Narayan

    2013-01-01

    Efficiently passing spiking messages in a neural model is an important aspect of high-performance simulation. As the scale of networks has increased so has the size of the computing systems required to simulate them. In addition, the information exchange of these resources has become more of an impediment to performance. In this paper we explore spike message passing using different mechanisms provided by the Message Passing Interface (MPI). A specific implementation, MVAPICH, designed for high-performance clusters with Infiniband hardware is employed. The focus is on providing information about these mechanisms for users of commodity high-performance spiking simulators. In addition, a novel hybrid method for spike exchange was implemented and benchmarked.

  20. UAVSAR Active Electronically-Scanned Array

    NASA Technical Reports Server (NTRS)

    Sadowy, Gregory; Brown, Kyle; Chamberlain, Neil; Figueroa, Harry; Fisher, Charlie; Grando, Maurio; Hamilton, Gary; Vorperian, Vatche; Zawadzki, Mark

    2010-01-01

    The Uninhabited Airborne Vehicle Synthetic Aperture Radar (UAVSAR) L-band (1.2-1.3 GHz) repeat pass, interferometric synthetic aperture radar (InSAR) used for Earth science applications. Using complex radar images collected during separate passes on time scales of hours to years, changes in surface topography can be measured. The repeat-pass InSAR technique requires that the radar look angle be approximately the same on successive passes. Due to variations in aircraft attitude between passes, antenna beam steering is required to replicate the radar look angle. This paper describes an active, electronically steered array (AESA) that provides beam steering capability in the antenna azimuth plane. The array contains 24 transmit/receive modules generating 2800 W of radiated power and is capable of pulse-to-pulse beam steering and polarization agility. Designed for high reliability as well as serviceability, all array electronics are contained in single 178cm x 62cm x 12 cm air-cooled panel suitable for operation up 60,000 ft altitude.

  1. Overtaking collision effects in a cw double-pass proton linac

    DOE PAGES

    Tao, Yue; Qiang, Ji; Hwang, Kilean

    2017-12-22

    The recirculating superconducting proton linac has the advantage of reducing the number of cavities in the accelerator and the corresponding construction and operational costs. Beam dynamics simulations were done recently in a double-pass recirculating proton linac using a single proton beam bunch. For continuous wave (cw) operation, the high-energy proton bunch during the second pass through the linac will overtake and collide with the low-energy bunch during the first pass at a number of locations of the linac. These collisions might cause proton bunch emittance growth and beam quality degradation. Here, we study the collisional effects due to Coulomb space-chargemore » forces between the high-energy bunch and the low-energy bunch. Our results suggest that these effects on the proton beam quality would be small and might not cause significant emittance growth or beam blowup through the linac. A 10 mA, 500 MeV cw double-pass proton linac is feasible without using extra hardware for phase synchronization.« less

  2. A new method for the automatic interpretation of Schlumberger and Wenner sounding curves

    USGS Publications Warehouse

    Zohdy, A.A.R.

    1989-01-01

    A fast iterative method for the automatic interpretation of Schlumberger and Wenner sounding curves is based on obtaining interpreted depths and resistivities from shifted electrode spacings and adjusted apparent resistivities, respectively. The method is fully automatic. It does not require an initial guess of the number of layers, their thicknesses, or their resistivities; and it does not require extrapolation of incomplete sounding curves. The number of layers in the interpreted model equals the number of digitized points on the sounding curve. The resulting multilayer model is always well-behaved with no thin layers of unusually high or unusually low resistivities. For noisy data, interpretation is done in two sets of iterations (two passes). Anomalous layers, created because of noise in the first pass, are eliminated in the second pass. Such layers are eliminated by considering the best-fitting curve from the first pass to be a smoothed version of the observed curve and automatically reinterpreting it (second pass). The application of the method is illustrated by several examples. -Author

  3. Multiple pass and multiple layer friction stir welding and material enhancement processes

    DOEpatents

    Feng, Zhili [Knoxville, TN; David, Stan A [Knoxville, TN; Frederick, David Alan [Harriman, TN

    2010-07-27

    Processes for friction stir welding, typically for comparatively thick plate materials using multiple passes and multiple layers of a friction stir welding tool. In some embodiments a first portion of a fabrication preform and a second portion of the fabrication preform are placed adjacent to each other to form a joint, and there may be a groove adjacent the joint. The joint is welded and then, where a groove exists, a filler may be disposed in the groove, and the seams between the filler and the first and second portions of the fabrication preform may be friction stir welded. In some embodiments two portions of a fabrication preform are abutted to form a joint, where the joint may, for example, be a lap joint, a bevel joint or a butt joint. In some embodiments a plurality of passes of a friction stir welding tool may be used, with some passes welding from one side of a fabrication preform and other passes welding from the other side of the fabrication preform.

  4. Evaluation of the utility of the Estimation of Physiologic Ability and Surgical Stress score for predicting post-operative morbidity after orthopaedic surgery.

    PubMed

    Nagata, Takehiro; Hirose, Jun; Nakamura, Takayuki; Tokunaga, Takuya; Uehara, Yusuke; Mizuta, Hiroshi

    2015-11-01

    The purpose of this study was to investigate the utility of the Estimation of Physiologic Ability and Surgical Stress (E-PASS) scoring system for predicting post-operative morbidity. We included 1,883 patients (mean age, 52.1 years) who underwent orthopaedic surgery. The post-operative complications were classified as surgical site and non-surgical site complications, and the relationship between the E-PASS scores and post-operative morbidity was investigated. The incidence of post-operative complications (n = 274) significantly increased with an increase in E-PASS scores (p < 0.001). The areas under the curve for the comprehensive risk score of the E-PASS scoring system for overall and non-surgical site complications were 0.777 and 0.794, respectively. The E-PASS scoring system showed some utility in predicting post-operative morbidity after general orthopaedic surgery. However, creating a new risk score that is more suitable for orthopaedic surgery will be challenging.

  5. Reflex ring laser amplifier system

    DOEpatents

    Summers, M.A.

    1983-08-31

    The invention is a method and apparatus for providing a reflex ring laser system for amplifying an input laser pulse. The invention is particularly useful in laser fusion experiments where efficient production of high-energy and high power laser pulses is required. The invention comprises a large aperture laser amplifier in an unstable ring resonator which includes a combination spatial filter and beam expander having a magnification greater than unity. An input pulse is injected into the resonator, e.g., through an aperture in an input mirror. The injected pulse passes through the amplifier and spatial filter/expander components on each pass around the ring. The unstable resonator is designed to permit only a predetermined number of passes before the amplified pulse exits the resonator. On the first pass through the amplifier, the beam fills only a small central region of the gain medium. On each successive pass, the beam has been expanded to fill the next concentric non-overlapping region of the gain medium.

  6. High frequency fishbone driven by passing energetic ions in tokamak plasmas

    NASA Astrophysics Data System (ADS)

    Wang, Feng; Yu, L. M.; Fu, G. Y.; Shen, Wei

    2017-05-01

    High frequency fishbone instability driven by passing energetic ions was first reported in the Princeton beta experiment with tangential neutral-beam-injection (Heidbrink et al 1986 Phys. Rev. Lett. 57 835-8). It could play an important role for ITER-like burning plasmas, where α particles are mostly passing particles. In this work, a generalized energetic ion distribution function and finite drift orbit width effect are considered to improve the theoretical model for passing particle driving fishbone instability. For purely passing energetic ions with zero drift orbit width, the kinetic energy δ {{W}k} is derived analytically. The derived analytic expression is more accurate as compared to the result of previous work (Wang 2001 Phys. Rev. Lett. 86 5286-8). For a generalized energetic ion distribution function, the fishbone dispersion relation is derived and is solved numerically. Numerical results show that broad and off-axis beam density profiles can significantly increase the beam ion beta threshold {βc} for instability and decrease mode frequency.

  7. High frequency fishbone driven by passing energetic ions in tokamak plasmas

    DOE PAGES

    Wang, Feng; Yu, L. M.; Fu, G. Y.; ...

    2017-03-22

    High frequency fishbone instability driven by passing energetic ions was first reported in the Princeton beta experiment with tangential neutral-beam-injection (Heidbrink et al 1986 Phys. Rev. Lett. 57 835–8). It could play an important role for ITER-like burning plasmas, where α particles are mostly passing particles. In this work, a generalized energetic ion distribution function and finite drift orbit width effect are considered to improve the theoretical model for passing particle driving fishbone instability. For purely passing energetic ions with zero drift orbit width, the kinetic energymore » $$\\delta {{W}_{k}}$$ is derived analytically. The derived analytic expression is more accurate as compared to the result of previous work. For a generalized energetic ion distribution function, the fishbone dispersion relation is derived and is solved numerically. As a result, numerical results show that broad and off-axis beam density profiles can significantly increase the beam ion beta threshold $${{\\beta}_{c}}$$ for instability and decrease mode frequency.« less

  8. Overtaking collision effects in a cw double-pass proton linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tao, Yue; Qiang, Ji; Hwang, Kilean

    The recirculating superconducting proton linac has the advantage of reducing the number of cavities in the accelerator and the corresponding construction and operational costs. Beam dynamics simulations were done recently in a double-pass recirculating proton linac using a single proton beam bunch. For continuous wave (cw) operation, the high-energy proton bunch during the second pass through the linac will overtake and collide with the low-energy bunch during the first pass at a number of locations of the linac. These collisions might cause proton bunch emittance growth and beam quality degradation. Here, we study the collisional effects due to Coulomb space-chargemore » forces between the high-energy bunch and the low-energy bunch. Our results suggest that these effects on the proton beam quality would be small and might not cause significant emittance growth or beam blowup through the linac. A 10 mA, 500 MeV cw double-pass proton linac is feasible without using extra hardware for phase synchronization.« less

  9. Optical ionization detector

    DOEpatents

    Wuest, C.R.; Lowry, M.E.

    1994-03-29

    An optical ionization detector wherein a beam of light is split so that one arm passes through a fiber optics and the other arm passes through a gas-filled region, and uses interferometry to detect density changes in a gas when charged particles pass through it. The gas-filled region of the detector is subjected to a high electric field and as a charged particle traverses this gas region electrons are freed from the cathode and accelerated so as to generate an electron avalanche which is collected on the anode. The gas density is effected by the electron avalanche formation and if the index or refraction is proportional to the gas density the index will change accordingly. The detector uses this index change by modulating the one arm of the split light beam passing through the gas, with respect to the other arm that is passed through the fiber optic. Upon recombining of the beams, interference fringe changes as a function of the index change indicates the passage of charged particles through the gaseous medium. 3 figures.

  10. Optical ionization detector

    DOEpatents

    Wuest, Craig R.; Lowry, Mark E.

    1994-01-01

    An optical ionization detector wherein a beam of light is split so that one arm passes through a fiber optics and the other arm passes through a gas-filled region, and uses interferometry to detect density changes in a gas when charged particles pass through it. The gas-filled region of the detector is subjected to a high electric field and as a charged particle traverses this gas region electrons are freed from the cathode and accelerated so as to generate an electron avalanche which is collected on the anode. The gas density is effected by the electron avalanche formation and if the index or refraction is proportional to the gas density the index will change accordingly. The detector uses this index change by modulating the one arm of the split light beam passing through the gas, with respect to the other arm that is passed through the fiber optic. Upon recombining of the beams, interference fringe changes as a function of the index change indicates the passage of charged particles through the gaseous medium.

  11. Analysis of the NASA/MSFC airborne Doppler lidar results from San Gorgonio Pass, California

    NASA Technical Reports Server (NTRS)

    Cliff, W. C.; Skarda, J. R.; Renne, D. S.; Sandusky, W. F.

    1985-01-01

    The NASA/MSFC Airborne Doppler Lidar System was flown in July 1981 aboard the NASA/Ames Convair 990 on the east side of San Gorgonio Pass California, near Palm Springs, to measure and investigate the accelerated atmospheric wind field discharging from the pass. At this region, the maritime layer from the west coast accelerates through the pass and spreads out over the valley floor on the east side of the pass. The experiment was selected in order to study accelerated flow in and at the exit of the canyon. Ground truth wind data taken concurrently with the flight data were available from approximately 12 meteorological towers and 3 tala kites for limited comparison purposes. The experiment provided the first spatial data for ensemble averaging of spatial correlations to compute lateral and longitudinal length scales in the lateral and longitudinal directions for both components, and information on atmospheric flow in this region of interest from wind energy resource considerations.

  12. Real-time digital signal recovery for a multi-pole low-pass transfer function system.

    PubMed

    Lee, Jhinhwan

    2017-08-01

    In order to solve the problems of waveform distortion and signal delay by many physical and electrical systems with multi-pole linear low-pass transfer characteristics, a simple digital-signal-processing (DSP)-based method of real-time recovery of the original source waveform from the distorted output waveform is proposed. A mathematical analysis on the convolution kernel representation of the single-pole low-pass transfer function shows that the original source waveform can be accurately recovered in real time using a particular moving average algorithm applied on the input stream of the distorted waveform, which can also significantly reduce the overall delay time constant. This method is generalized for multi-pole low-pass systems and has noise characteristics of the inverse of the low-pass filter characteristics. This method can be applied to most sensors and amplifiers operating close to their frequency response limits to improve the overall performance of data acquisition systems and digital feedback control systems.

  13. Do People Prefer to Pass Along Good or Bad News? Valence and Relevance of News as Predictors of Transmission Propensity

    PubMed

    Heath

    1996-11-01

    Anecdotal evidence seems to indicate that exaggeratedly bad news may propagate in the marketplace of ideas. Three studies investigate whether people prefer to pass along pieces of bad news or good news that are equated for "surprisingness." People typically prefer to pass along central rather than extreme information (i.e., news that is less surprising rather than more surprising). However, when confronted with extreme information, the results support a preference for congruence, that is, people prefer to pass along news that is congruent with the emotional valence of the domain in question. This means that in emotionally negative domains, contrary to some theoretical predictions, people are willing to pass along bad news even when it is exaggeratedly bad. At the same time, however, people transmit exaggeratedly good news in emotionally positive domains. The general discussion indicates how these results may inform research on word of mouth for consumer products and social relations in organizations.

  14. Computer-Based Algorithmic Determination of Muscle Movement Onset Using M-Mode Ultrasonography

    DTIC Science & Technology

    2017-05-01

    contraction images were analyzed visually and with three different classes of algorithms: pixel standard deviation (SD), high-pass filter and Teager Kaiser...Linear relationships and agreements between computed and visual muscle onset were calculated. The top algorithms were high-pass filtered with a 30 Hz...suggest that computer automated determination using high-pass filtering is a potential objective alternative to visual determination in human

  15. Catalytic reactor for promoting a chemical reaction on a fluid passing therethrough

    NASA Technical Reports Server (NTRS)

    Roychoudhury, Subir (Inventor); Pfefferle, William C. (Inventor)

    2001-01-01

    A catalytic reactor with an auxiliary heating structure for raising the temperature of a fluid passing therethrough whereby the catalytic reaction is promoted. The invention is a apparatus employing multiple electrical heating elements electrically isolated from one another by insulators that are an integral part of the flow path. The invention provides step heating of a fluid as the fluid passes through the reactor.

  16. Passing the Bubble: Cognitive Efficiency of Augmented Video for Collaborative Transfer of Situational Understanding

    DTIC Science & Technology

    2003-01-01

    media factors affecting: • Shared Understanding – explicit and operational knowledge • Decision-Making – what information format best helps decision...Passing the Bubble: Cognitive Efficiency of Augmented Video for Collaborative Transfer of Situational Understanding Collaboration and Knowledge ...operational knowledge ? • Informed Decision-Making – what information format is best to pass the bubble to a decision-maker 1/14/2003 ONR David Kirsh

  17. Modification of the flow pass method as applied to problems of chemistry of planet atmospheres

    NASA Technical Reports Server (NTRS)

    Parshev, V. A.

    1980-01-01

    It was shown that the modified flow pass method possesses considerable effectiveness, both in the case when the coefficient of diffusion changes severely in the examined region and in the case when diffusion is the prevalent process, as compared with chemical reactions. The case when a regular pass proves inapplicable, or applicable in a limited interval of the decisive parameters, was examined.

  18. Defense Authorization and Appropriations Bills: FY1970-FY2017

    DTIC Science & Technology

    2017-01-18

    9/29/95 # 700 (y151-n267) S. 1087 104-124 7/28/95 Hh 9/5/95 # 397 (y62-n35) 104-344 11/16/95 # 806 (y270-n158) — 104-344 11/16...Senate passed S. 3189 on October 15, 1990, then vitiated this action on October 16, 1990, and passed H.R. 5803 in lieu. h. Senate passed S. 1087

  19. Defense Authorization and Appropriations Bills: FY1970-FY2016

    DTIC Science & Technology

    2016-04-20

    103-335 9/30/94 1996 H.R. 2126 104-208 7/27/95 9/7/95 # 646 (y294-n125) 104-261 9/29/95 # 700 (y151-n267) S. 1087 104-124 7/28/95 Hh...1990, and passed H.R. 5803 in lieu. h. Senate passed S. 1087 , amended by recorded vote # 397 on September 5, 1995, then passed H.R. 2126 in lieu on

  20. Do Differences in Programmatic Resource Investments Result in Different 3-Year Pass Rates on the U.S. National Physical Therapy Examination?

    PubMed

    Covington, Kyle; McCallum, Christine; Engelhard, Chalee; Landry, Michel D; Cook, Chad

    2016-01-01

    The rising cost of health professions education is well documented and a growing concern among educators; however, little is known about the implications of resource investment on student success. The objective of this study was to determine whether programs with higher National Physical Therapist Exam (NPTE) pass rates invested significantly more on programmatic resources. This observational study used data from the Commission on Accreditation in Physical Therapy Education's (CAPTE) Annual Accreditation Report including all accredited physical therapist programs from the United States who graduated physical therapist students in 2011. Resource expenditures were recorded as both raw and as an index variable (resources per student). Descriptive statistics and comparisons (using chi-square and t-tests) among programs with <100% and 100% pass rates were analyzed from 2009-2011. An ANCOVA was used to determine differences in raw resource expenditures and resource expenditures per student. There were no differences in raw resource expenditures between programs with <100% and 100% pass rates. Programs with 100% pass rates were provided more resource expenditures per student for personnel, overall budget, and core faculty. The results of this study suggest programs with 100% pass rates invested significantly more per student for selected resources.

  1. Introducing passive acoustic filter in acoustic based condition monitoring: Motor bike piston-bore fault identification

    NASA Astrophysics Data System (ADS)

    Jena, D. P.; Panigrahi, S. N.

    2016-03-01

    Requirement of designing a sophisticated digital band-pass filter in acoustic based condition monitoring has been eliminated by introducing a passive acoustic filter in the present work. So far, no one has attempted to explore the possibility of implementing passive acoustic filters in acoustic based condition monitoring as a pre-conditioner. In order to enhance the acoustic based condition monitoring, a passive acoustic band-pass filter has been designed and deployed. Towards achieving an efficient band-pass acoustic filter, a generalized design methodology has been proposed to design and optimize the desired acoustic filter using multiple filter components in series. An appropriate objective function has been identified for genetic algorithm (GA) based optimization technique with multiple design constraints. In addition, the sturdiness of the proposed method has been demonstrated in designing a band-pass filter by using an n-branch Quincke tube, a high pass filter and multiple Helmholtz resonators. The performance of the designed acoustic band-pass filter has been shown by investigating the piston-bore defect of a motor-bike using engine noise signature. On the introducing a passive acoustic filter in acoustic based condition monitoring reveals the enhancement in machine learning based fault identification practice significantly. This is also a first attempt of its own kind.

  2. An update on the potential role of intestinal first-pass metabolism for the prediction of drug-drug interactions: the role of PBPK modeling.

    PubMed

    Alqahtani, Saeed; Bukhari, Ishfaq; Albassam, Ahmed; Alenazi, Maha

    2018-05-28

    The intestinal absorption process is a combination of several events that are governed by various factors. Several transport mechanisms are involved in drug absorption through enterocytes via active and/or passive processes. The transported molecules then undergo intestinal metabolism, which together with intestinal transport may affect the systemic availability of drugs. Many studies have provided clear evidence on the significant role of intestinal first-pass metabolism on drug bioavailability and degree of drug-drug interactions (DDIs). Areas covered: This review provides an update on the role of intestinal first-pass metabolism in the oral bioavailability of drugs and prediction of drug-drug interactions. It also provides a comprehensive overview and summary of the latest update in the role of PBPK modeling in prediction of intestinal metabolism and DDIs in humans. Expert opinion: The contribution of intestinal first-pass metabolism in the oral bioavailability of drugs and prediction of DDIs has become more evident over the last few years. Several in vitro, in situ, and in vivo models have been developed to evaluate the role of first-pass metabolism and to predict DDIs. Currently, physiologically based pharmacokinetic modeling is considered the most valuable tool for the prediction of intestinal first-pass metabolism and DDIs.

  3. Pass rates on the American Board of Family Medicine Certification Exam by residency location and size.

    PubMed

    Falcone, John L; Middleton, Donald B

    2013-01-01

    The Accreditation Council for Graduate Medical Education (ACGME) sets residency performance standards for the American Board of Family Medicine Certification Examination. This study aims are to describe the compliance of residency programs with ACGME standards and to determine whether residency pass rates depend on program size and location. In this retrospective cohort study, residency performance from 2007 to 2011 was compared with the ACGME performance standards. Simple linear regression was performed to see whether program pass rates were dependent on program size. Regional differences in performance were compared with χ(2) tests, using an α level of 0.05. Of 429 total residency programs, there were 205 (47.8%) that violate ACGME performance standards. Linear regression showed that program pass rates were positively correlated and dependent on program size (P < .001). The median pass rate per state was 86.4% (interquartile range, 82.0-90.8. χ(2) Tests showed that states in the West performed higher than the other 3 US Census Bureau Regions (all P < .001). Approximately half of the family medicine training programs do not meet the ACGME examination performance standards. Pass rates are associated with residency program size, and regional variation occurs. These findings have the potential to affect ACGME policy and residency program application patterns.

  4. Exploring Team Passing Networks and Player Movement Dynamics in Youth Association Football

    PubMed Central

    Coutinho, Diogo; Santos, Sara; Lago-Penas, Carlos; Jiménez, Sergio; Sampaio, Jaime

    2017-01-01

    Understanding how youth football players base their game interactions may constitute a solid criterion for fine-tuning the training process and, ultimately, to achieve better individual and team performances during competition. The present study aims to explore how passing networks and positioning variables can be linked to the match outcome in youth elite association football. The participants included 44 male elite players from under-15 and under-17 age groups. A passing network approach within positioning-derived variables was computed to identify the contributions of individual players for the overall team behaviour outcome during a simulated match. Results suggested that lower team passing dependency for a given player (expressed by lower betweenness network centrality scores) and high intra-team well-connected passing relations (expressed by higher closeness network centrality scores) were related to better outcomes. The correlation between the dyads’ positioning regularity and the passing density showed a most likely higher correlation in under-15 (moderate effect), indicating a possible more dependence of the ball position rather than in the under-17 teams (small/unclear effects). Overall, this study emphasizes the potential of coupling notational analyses with spatial-temporal relations to produce a more functional and holistic understanding of teams’ sports performance. Also, the social network analysis allowed to reveal novel key determinants of collective performance. PMID:28141823

  5. Security analysis and improvements to the PsychoPass method.

    PubMed

    Brumen, Bostjan; Heričko, Marjan; Rozman, Ivan; Hölbl, Marko

    2013-08-13

    In a recent paper, Pietro Cipresso et al proposed the PsychoPass method, a simple way to create strong passwords that are easy to remember. However, the method has some security issues that need to be addressed. To perform a security analysis on the PsychoPass method and outline the limitations of and possible improvements to the method. We used the brute force analysis and dictionary attack analysis of the PsychoPass method to outline its weaknesses. The first issue with the Psychopass method is that it requires the password reproduction on the same keyboard layout as was used to generate the password. The second issue is a security weakness: although the produced password is 24 characters long, the password is still weak. We elaborate on the weakness and propose a solution that produces strong passwords. The proposed version first requires the use of the SHIFT and ALT-GR keys in combination with other keys, and second, the keys need to be 1-2 distances apart. The proposed improved PsychoPass method yields passwords that can be broken only in hundreds of years based on current computing powers. The proposed PsychoPass method requires 10 keys, as opposed to 20 keys in the original method, for comparable password strength.

  6. Deformation Behavior and Microstructure Evolution of As-Cast 42CrMo Alloy in Isothermal and Non-isothermal Compression

    NASA Astrophysics Data System (ADS)

    Qin, Fangcheng; Li, Yongtang; Qi, Huiping; Lv, Zhenhua

    2016-11-01

    The isothermal and non-isothermal multi-pass compression tests of centrifugal casting 42CrMo steel were conducted on a Gleeble-3500 thermal simulation machine. The effects of compression passes and finishing temperatures on deformation behavior and microstructure evolution were investigated. It is found that the microstructure is homogeneous with equiaxed grains, and the flow stress does not show significant change with the increase in passes, while the peak softening coefficient increases first and then decreases during inter-pass. Moreover, the dominant mechanisms of controlled temperature and accumulated static recrystallization for grain refinement and its homogeneous distribution are found after 5 passes deformation. As the finishing temperature increases, the flow stress decreases gradually, but the dynamic recrystallization accelerates and softening effect increases, resulting in the larger grain size and homogeneous microstructure. The microhardness decreases sharply because the sufficient softening occurs in microstructure. When the finishing temperature is 890 °C, the carbide particles are precipitated in the vicinity of the grain boundaries, thus inhibiting the dislocation motion. Thus, the higher finishing temperature (≥970 °C) for centrifugal casting 42CrMo alloy should be avoided in non-isothermal multi-pass deformation, which is beneficial to grain refinement and properties improvement.

  7. The Predictors and Determinants of Inter-Seasonal Success in a Professional Soccer Team

    PubMed Central

    Kite, Christopher S.; Nevill, Alan

    2017-01-01

    Abstract The aims of this study were to 1) directly compare the performances of a professional soccer team over three seasons, 2) identify key variables that discriminated between a successful or unsuccessful performance, and 3) identify variables that best predicted success. ANOVA revealed that attempted and completed passes were significantly lower (both p < 0.001) in the most successful season (S1). Additionally, shot effectiveness was significantly less (p < 0.001) in their least successful season (S3) (vs S1 -11.61%; d = 0.735; vs S2 -12.02%; d = 0.760). When the match outcome was considered, they attempted significantly fewer passes when they won (-60.26; p = 0.002; d = -0.729) or drew (-44.87; p = 0.023; d = -0.543) compared to when they lost. The binary logistic regression analysis also retained passing variables. The team should attempt fewer passes, but ensure that more of these passes are completed. With away matches, the effect became more pronounced (β = -0.042, OR = 0.959, p = 0.012). In conclusion, the team should adopt a more direct style of play. They should move the ball into a shooting position with fewer passes and ensure that more shots are on the target. PMID:28828086

  8. A prototype for the PASS Permanent All Sky Survey

    NASA Astrophysics Data System (ADS)

    Deeg, H. J.; Alonso, R.; Belmonte, J. A.; Horne, K.; Alsubai, K.; Collier Cameron, A.; Doyle, L. R.

    2004-10-01

    A prototype system for the Permanent All Sky Survey (PASS) project is presented. PASS is a continuous photometric survey of the entire celestial sphere with a high temporal resolution. Its major objectives are the detection of all giant-planet transits (with periods up to some weeks) across stars up to mag 10.5, and to deliver continuously photometry that is useful for the study of any variable stars. The prototype is based on CCD cameras with short focal length optics on a fixed mount. A small dome to house it at Teide Observatory, Tenerife, is currently being constructed. A placement at the antarctic Dome C is also being considered. The prototype will be used for a feasibility study of PASS, to define the best observing strategies, and to perform a detailed characterization of the capabilities and scope of the survey. Afterwards, a first partial sky surveying will be started with it. That first survey may be able to detect transiting planets during its first few hundred hours of operation. It will also deliver a data set around which software modules dealing with the various scientific objectives of PASS will be developed. The PASS project is still in its early phase and teams interested in specific scientific objectives, in providing technical expertise, or in participating with own observations are invited to collaborate.

  9. Cyclone reactor with internal separation and axial recirculation

    DOEpatents

    Becker, F.E.; Smolensky, L.A.

    1988-07-19

    A cyclone combustor apparatus contains a circular partition plate containing a central circular aperture is described. The partition plate divides the apparatus into a cylindrical precombustor chamber and a combustor chamber. A coal-water slurry is passed axially into the inlet end of the precombustor chamber, and primary air is passed tangentially into said chamber to establish a cyclonic air flow. Combustion products pass through the partition plate aperture and into the combustor chamber. Secondary air may also be passed tangentially into the combustor chamber adjacent the partition plate to maintain the cyclonic flow. Flue gas is passed axially out of the combustor chamber at the outlet end and ash is withdrawn tangentially from the combustor chamber at the outlet end. A first mixture of flue gas and ash may be tangentially withdrawn from the combustor chamber at the outlet end and recirculated to the axial inlet of the precombustor chamber with the coal-water slurry. A second mixture may be tangentially withdrawn from the outlet end and passed to a heat exchanger for cooling. Cooled second mixture is then recirculated to the axial inlet of the precombustor chamber. In another embodiment a single cyclone combustor chamber is provided with both the recirculation streams of the first mixture and the second mixture. 10 figs.

  10. Cyclone reactor with internal separation and axial recirculation

    DOEpatents

    Becker, Frederick E.; Smolensky, Leo A.

    1989-01-01

    A cyclone combustor apparatus contains a circular partition plate containing a central circular aperture. The partition plate divides the apparatus into a cylindrical precombustor chamber and a combustor chamber. A coal-water slurry is passed axially into the inlet end of the precombustor chamber, and primary air is passed tangentially into said chamber to establish a cyclonic air flow. Combustion products pass through the partition plate aperture and into the combustor chamber. Secondary air may also be passed tangentially into the combustor chamber adjacent the partition plate to maintain the cyclonic flow. Flue gas is passed axially out of the combustor chamber at the outlet end and ash is withdrawn tangentially from the combuston chamber at the outlet end. A first mixture of flue gas and ash may be tangentially withdrawn from the combustor chamber at the outlet end and recirculated to the axial inlet of the precombustor chamber with the coal-water slurry. A second mixture of flue gas and ash may be tangentially withdrawn from the outlet end of the combustor chamber and passed to a heat exchanger for cooling. Cooled second mixture is then recirculated to the axial inlet of the precombustor chamber. In another embodiment a single cyclone combustor chamber is provided with both the recirculation streams of the first mixture and the second mixture.

  11. [The permanence of access to health care: a tradition of hospitality and innovative organizational model].

    PubMed

    Georges-Tarragano, C

    2015-01-01

    The PASS ("Permanence d'Accès aux Soins de Santé") are hospital-based units providing primary care services to patients who lack health care coverage. Using a "whole person" approach and providing a combination of health and social care, the PASS offer an appropriately adapted response to complex health problems within a context of marked social vulnerability and contribute to reducing health inequalities. The PASS are an example of an interdisciplinary approach to health care which contrasts with the segmentary approach typical of conventional hospital departments. Operating at the interface between primary and secondary care, the PASS have the potential to become key players in developing models of patient pathways. Their presence reduces inappropriate emergency attendances and hospitalisation by offering medical care in a timely fashion, in an outpatient-type setting. The PASS can provide a resource for research into optimum models of health care, where the social context of health needs are fully recognized and inform medical treatment appropriately. According to their potential development, PASS are living labs of an innovative organizational model of care. Copyright © 2014 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  12. Security Analysis and Improvements to the PsychoPass Method

    PubMed Central

    2013-01-01

    Background In a recent paper, Pietro Cipresso et al proposed the PsychoPass method, a simple way to create strong passwords that are easy to remember. However, the method has some security issues that need to be addressed. Objective To perform a security analysis on the PsychoPass method and outline the limitations of and possible improvements to the method. Methods We used the brute force analysis and dictionary attack analysis of the PsychoPass method to outline its weaknesses. Results The first issue with the Psychopass method is that it requires the password reproduction on the same keyboard layout as was used to generate the password. The second issue is a security weakness: although the produced password is 24 characters long, the password is still weak. We elaborate on the weakness and propose a solution that produces strong passwords. The proposed version first requires the use of the SHIFT and ALT-GR keys in combination with other keys, and second, the keys need to be 1-2 distances apart. Conclusions The proposed improved PsychoPass method yields passwords that can be broken only in hundreds of years based on current computing powers. The proposed PsychoPass method requires 10 keys, as opposed to 20 keys in the original method, for comparable password strength. PMID:23942458

  13. Establishing pass/fail criteria for bronchoscopy performance.

    PubMed

    Konge, Lars; Clementsen, Paul; Larsen, Klaus Richter; Arendrup, Henrik; Buchwald, Christian; Ringsted, Charlotte

    2012-01-01

    Several tools have been created to assess competence in bronchoscopy. However, educational guidelines still use an arbitrary number of performed procedures to decide when basic competency is acquired. The purpose of this study was to define pass/fail scores for two bronchoscopy assessment tools, and investigate how these scores relate to physicians' experience regarding the number of bronchoscopy procedures performed. We studied two assessment tools and used two standard setting methods to create cut scores: the contrasting-groups method and the extended Angoff method. In the first we compared bronchoscopy performance scores of 14 novices with the scores of 14 experienced consultants to find the score that best discriminated between the two groups. In the second we asked an expert group of 7 experienced bronchoscopists to judge how a borderline trainee would perform on each item of the test. Using the contrasting-groups method we found a standard that would fail all novices and pass all consultants. A clear pass related to prior experience of 75 procedures. The consequences of using the extended Angoff method were also acceptable: all trainees who had performed less than 50 bronchoscopies failed the test and all consultants passed. A clear pass related to 80 procedures. Our proposed pass/fail scores for these two methods seem appropriate in terms of consequences. Prior experience with the performance of 75 and 80 bronchoscopies, respectively, seemed to ensure basic competency. In the future objective assessment tools could become an important aid in the certification of physicians performing bronchoscopies. Copyright © 2011 S. Karger AG, Basel.

  14. Setting and validating the pass/fail score for the NBDHE.

    PubMed

    Tsai, Tsung-Hsun; Dixon, Barbara Leatherman

    2013-04-01

    This report describes the overall process used for setting the pass/fail score for the National Board Dental Hygiene Examination (NBDHE). The Objective Standard Setting (OSS) method was used for setting the pass/fail score for the NBDHE. The OSS method requires a panel of experts to determine the criterion items and proportion of these items that minimally competent candidates would answer correctly, the percentage of mastery and the confidence level of the error band. A panel of 11 experts was selected by the Joint Commission on National Dental Examinations (Joint Commission). Panel members represented geographic distribution across the U.S. and had the following characteristics: full-time dental hygiene practitioners with experience in areas of preventive, periodontal, geriatric and special needs care, and full-time dental hygiene educators with experience in areas of scientific basis for dental hygiene practice, provision of clinical dental hygiene services and community health/research principles. Utilizing the expert panel's judgments, the pass/fail score was set and then the score scale was established using the Rasch measurement model. Statistical and psychometric analysis shows the actual failure rate and the OSS failure rate are reasonably consistent (2.4% vs. 2.8%). The analysis also showed the lowest error of measurement, an index of the precision at the pass/fail score point and that the highest reliability (0.97) are achieved at the pass/fail score point. The pass/fail score is a valid guide for making decisions about candidates for dental hygiene licensure. This new standard was reviewed and approved by the Joint Commission and was implemented beginning in 2011.

  15. Melanogenesis inhibition in mice using a low-fluence 1064-nm Q-switched neodymium-doped yttrium aluminum garnet laser: a pilot study.

    PubMed

    Nam, Jae-Hui; Min, Joon Hong; Kim, Wang-Kyun; Yim, Sunmin; Kim, Won-Serk

    2017-07-01

    A low-fluence 1064-nm Q-switched neodymium-doped yttrium aluminum garnet laser, or laser toning, has yielded favorable outcomes in various benign pigmented disorders. However, the exact mechanism of action of laser toning has not been fully elucidated. We sought to determine the inhibitory effect of laser toning on melanogenesis and to assess how laser passes influence the outcomes. To produce perceptible pigmentation, nine HRM-2 melanin-possessing hairless mice were treated with ultraviolet (UV) B radiation on the dorsal skin. This was followed by zero, two, four, or six passes of laser toning twice in 2 weeks on each designated quadrant. The spectrophotometric values and pigmentation-related protein expressions were measured. Pigment changes were found in the mice skin using the Fontana-Masson stain for histopathological analysis. Four- and six-pass laser toning significantly improved the lightness compared to that in the unirradiated control (p < 0.002). The Fontana-Masson stain showed that melanin was considerably decreased in laser-irradiated skin. As the number of laser passes increased, the expression of tyrosinase decreased (p < 0.008). The following parameters also decreased in proportion to the number of laser passes: MITF, TRP-1, TRP-2, p-ERK, and p-Akt. In contrast, TGF-β increased in proportion to the number of laser passes. However, the changes in these six proteins were not statistically significant. Our study demonstrates that laser toning improves skin pigmentation with increased number of passes in a dose-dependent manner. This effect is mediated by tyrosinase inhibition.

  16. Effectiveness of Spiritist "passe" (Spiritual healing) for anxiety levels, depression, pain, muscle tension, well-being, and physiological parameters in cardiovascular inpatients: A randomized controlled trial.

    PubMed

    Carneiro, Élida Mara; Barbosa, Luana Pereira; Marson, Jorge Marcelo; Terra, Juverson Alves; Martins, Claudio Jacinto Pereira; Modesto, Danielle; Resende, Luiz Antônio Pertili Rodrigues de; Borges, Maria de Fátima

    2017-02-01

    Biofield therapies, such as laying on of hands, are used in association with Conventional Medicine as Spiritist "passe", among others. The aim of this study was to evaluate anxiety, depression, pain, muscle tension and well-being, as well as physiological parameters in cardiovascular inpatients submitted to the Spiritist "passe", sham, and no intervention. In the total, 41 cardiovascular inpatients submitted to the Spiritist "passe", sham, and no intervention during a 10-min period on 3 consecutive days. They were evaluated through anxiety and depression level, pain, the perceptions of muscle tension and well-being and physiological parameters, before and after interventions. A significant reduction (p=0.001) in anxiety scores and muscle tension (p=0.011), improvement of well-being (p=0.003) and a significant increase in peripheral oxyhemoglobin saturation scores (p=0.028) were observed in Spiritist "passe" patients, and a significant reduction (p=0.028) of muscle tension and improvement of well-being (p=0.045) in sham patients. However, muscle tension reduction (p=0.003) and improvement of well-being (p=0.003) were more accentuated in the Spiritist "passe" compared to sham and no intervention. Results suggest that the Spiritist "passe" appeared to be effective, reducing anxiety level and the perception of muscle tension, consequently improving peripheral oxyhemoglobin saturation and the sensation of well-being compared to sham and no intervention in cardiovascular inpatients. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Multiple-rotor-cycle 2D PASS experiments with applications to (207)Pb NMR spectroscopy.

    PubMed

    Vogt, F G; Gibson, J M; Aurentz, D J; Mueller, K T; Benesi, A J

    2000-03-01

    Thetwo-dimensional phase-adjusted spinning sidebands (2D PASS) experiment is a useful technique for simplifying magic-angle spinning (MAS) NMR spectra that contain overlapping or complicated spinning sideband manifolds. The pulse sequence separates spinning sidebands by their order in a two-dimensional experiment. The result is an isotropic/anisotropic correlation experiment, in which a sheared projection of the 2D spectrum effectively yields an isotropic spectrum with no sidebands. The original 2D PASS experiment works best at lower MAS speeds (1-5 kHz). At higher spinning speeds (8-12 kHz) the experiment requires higher RF power levels so that the pulses do not overlap. In the case of nuclei such as (207)Pb, a large chemical shift anisotropy often yields too many spinning sidebands to be handled by a reasonable 2D PASS experiment unless higher spinning speeds are used. Performing the experiment at these speeds requires fewer 2D rows and a correspondingly shorter experimental time. Therefore, we have implemented PASS pulse sequences that occupy multiple MAS rotor cycles, thereby avoiding pulse overlap. These multiple-rotor-cycle 2D PASS sequences are intended for use in high-speed MAS situations such as those required by (207)Pb. A version of the multiple-rotor-cycle 2D PASS sequence that uses composite pulses to suppress spectral artifacts is also presented. These sequences are demonstrated on (207)Pb test samples, including lead zirconate, a perovskite-phase compound that is representative of a large class of interesting materials. Copyright 2000 Academic Press.

  18. Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor.

    PubMed

    Vilaseca, Meritxell; Arjona, Montserrat; Pujol, Jaume; Peris, Elvira; Martínez, Vanessa

    2013-01-01

    To evaluate the accuracy of spherical equivalent (SE) estimates of a double-pass system and to compare it with retinoscopy, subjective refraction and a table-mounted autorefractor. Non-cycloplegic refraction was performed on 125 eyes of 65 healthy adults (age 23.5±3.0 years) from October 2010 to January 2011 using retinoscopy, subjective refraction, autorefraction (Auto kerato-refractometer TOPCON KR-8100, Japan) and a double-pass system (Optical Quality Analysis System, OQAS, Visiometrics S.L., Spain). Nine consecutive measurements with the double-pass system were performed on a subgroup of 22 eyes to assess repeatability. To evaluate the trueness of the OQAS instrument, the SE laboratory bias between the double-pass system and the other techniques was calculated. The SE mean coefficient of repeatability obtained was 0.22D. Significant correlations could be established between the OQAS and the SE obtained with retinoscopy (r=0.956, P<0.001), subjective refraction (r=0.955, P<0.001) and autorefraction (r=0.957, P<0.001). The differences in SE between the double-pass system and the other techniques were significant (P<0.001), but lacked clinical relevance except for retinoscopy; Retinoscopy gave more hyperopic values than the double-pass system -0.51±0.50D as well as the subjective refraction -0.23±0.50D; More myopic values were achieved by means of autorefraction 0.24±0.49D. The double-pass system provides accurate and reliable estimates of the SE that can be used for clinical studies. This technique can determine the correct focus position to assess the ocular optical quality. However, it has a relatively small measuring range in comparison with autorefractors (-8.00 to +5.00D), and requires prior information on the refractive state of the patient.

  19. Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor

    PubMed Central

    Vilaseca, Meritxell; Arjona, Montserrat; Pujol, Jaume; Peris, Elvira; Martínez, Vanessa

    2013-01-01

    AIM To evaluate the accuracy of spherical equivalent (SE) estimates of a double-pass system and to compare it with retinoscopy, subjective refraction and a table-mounted autorefractor. METHODS Non-cycloplegic refraction was performed on 125 eyes of 65 healthy adults (age 23.5±3.0 years) from October 2010 to January 2011 using retinoscopy, subjective refraction, autorefraction (Auto kerato-refractometer TOPCON KR-8100, Japan) and a double-pass system (Optical Quality Analysis System, OQAS, Visiometrics S.L., Spain). Nine consecutive measurements with the double-pass system were performed on a subgroup of 22 eyes to assess repeatability. To evaluate the trueness of the OQAS instrument, the SE laboratory bias between the double-pass system and the other techniques was calculated. RESULTS The SE mean coefficient of repeatability obtained was 0.22D. Significant correlations could be established between the OQAS and the SE obtained with retinoscopy (r=0.956, P<0.001), subjective refraction (r=0.955, P<0.001) and autorefraction (r=0.957, P<0.001). The differences in SE between the double-pass system and the other techniques were significant (P<0.001), but lacked clinical relevance except for retinoscopy; Retinoscopy gave more hyperopic values than the double-pass system -0.51±0.50D as well as the subjective refraction -0.23±0.50D; More myopic values were achieved by means of autorefraction 0.24±0.49D. CONCLUSION The double-pass system provides accurate and reliable estimates of the SE that can be used for clinical studies. This technique can determine the correct focus position to assess the ocular optical quality. However, it has a relatively small measuring range in comparison with autorefractors (-8.00 to +5.00D), and requires prior information on the refractive state of the patient. PMID:24195036

  20. The thermal structure of Titan’s upper atmosphere, I: Temperature profiles from Cassini INMS observations

    NASA Astrophysics Data System (ADS)

    Snowden, D.; Yelle, R. V.; Cui, J.; Wahlund, J.-E.; Edberg, N. J. T.; Ågren, K.

    2013-09-01

    We derive vertical temperature profiles from Ion Neutral Mass Spectrometer (INMS) N2 density measurements from 32 Cassini passes. We find that the average temperature of Titan’s thermosphere varies significantly from pass-to-pass between 112 and 175 K. The temperatures from individual temperature profiles also varies considerably, with many passes exhibiting wave-like temperature perturbations and large temperature gradients. Wave-like temperature perturbations have wavelengths between 150 and 420 km and amplitudes between 3% and 22% and vertical wave power spectra of the INMS data and HASI data have a slope between -2 and -3, which is consistent with vertically propagating atmospheric waves. The lack of a strong correlation between temperature and latitude, longitude, solar zenith angle, or local solar time indicates that the thermal structure of Titan’s thermosphere is not primarily determined by the absorption of solar EUV flux. At N2 densities greater than 108 cm-3, Titan’s thermosphere is colder when Titan is observed in Saturn’s magnetospheric lobes compared to Saturn’s plasma sheet as proposed by Westlake et al. (Westlake, J.H. et al. [2011]. J. Geophys. Res. 116, A03318. http://dx.doi.org/10.1029/2010JA016251). This apparent correlation suggests that magnetospheric particle precipitation causes the temperature variability in Titan’s thermosphere; however, at densities smaller than 108 cm-3 the lobe passes are hotter than the plasma sheet passes and we find no correlation between the temperature of Titan’s thermosphere and ionospheric signatures of enhanced particle precipitation, which suggests that the correlation is not indicative of a physical connection. The temperature of Titan’s thermosphere also may have decreased by ∼10 K around mid-2007. Finally, we classify the vertical temperature profiles to show which passes are hot and cold and which passes have the largest temperature variations. In a companion paper (Part II), we estimate the strength of energy sources and sinks in Titan’s thermosphere.

  1. WE-D-BRA-06: IMRT QA with ArcCHECK: The MD Anderson Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aristophanous, M; Suh, Y; Chi, P

    Purpose: The objective of this project was to report our initial IMRT QA results and experience with the SunNuclear ArcCHECK. Methods: Three thousand one-hundred and sixteen cases were treated with IMRT or VMAT at our institution between October 2013 and September 2014. All IMRT/VMAT treatment plans underwent Quality Assurance (QA) using ArcCHECK prior to therapy. For clinical evaluation, a Gamma analysis is performed following QA delivery using the SNC Patient software (Sun Nuclear Corp) at the 3%/3mm level. QA Gamma pass rates were analyzed based on categories of treatment site, technique, and type of MLCs. Our current clinical threshold formore » passing a QA (Tclin) is set at a Gamma pass rate greater than 90%. We recorded the percent of failures for each category, as well as the Gamma pass rate threshold that would Result in 95% of QAs to pass (T95). Results: Using Tclin a failure rate of 5.9% over all QAs was observed. The highest failure rate was observed for gynecological (22%) and the lowest for CNS (0.9%) treatments. T95 was 91% over all QAs and ranged from 73% (gynecological) to 96.5% (CNS) for individual treatments sites. T95 was lower for IMRT and non-HD (high definition) MLCs at 88.5% and 94.5%, respectively, compared to 92.4% and 97.1% for VMAT and HD MLC treatments, respectively. There was a statistically significant difference between the passing rates for IMRT vs. VMAT and for HD MLCs vs. non-HD MLCs (p-values << 0.01). Gynecological, IMRT, and HD MLC treatments typically include more plans with larger field sizes. Conclusion: On average, Tclin with ArcCHECK was consistent with T95, as well as the 90% action level reported in TG-119. However, significant variations between the examined categories suggest a link between field size and QA passing rates and may warrant field size-specific passing rate thresholds.« less

  2. Fundamental Use of Surgical Energy (FUSE) certification: validation and predictors of success.

    PubMed

    Robinson, Thomas N; Olasky, Jaisa; Young, Patricia; Feldman, Liane S; Fuchshuber, Pascal R; Jones, Stephanie B; Madani, Amin; Brunt, Michael; Mikami, Dean; Jackson, Gretchen P; Mischna, Jessica; Schwaitzberg, Steven; Jones, Daniel B

    2016-03-01

    The Fundamental Use of Surgical Energy (FUSE) program includes a Web-based didactic curriculum and a high-stakes multiple-choice question examination with the goal to provide certification of knowledge on the safe use of surgical energy-based devices. The purpose of this study was (1) to set a passing score through a psychometrically sound process and (2) to determine what pretest factors predicted passing the FUSE examination. Beta-testing of multiple-choice questions on 62 topics of importance to the safe use of surgical energy-based devices was performed. Eligible test takers were physicians with a minimum of 1 year of surgical training who were recruited by FUSE task force members. A pretest survey collected baseline information. A total of 227 individuals completed the FUSE beta-test, and 208 completed the pretest survey. The passing/cut score for the first test form of the FUSE multiple-choice examination was determined using the modified Angoff methodology and for the second test form was determined using a linear equating methodology. The overall passing rate across the two examination forms was 81.5%. Self-reported time studying the FUSE Web-based curriculum for a minimum of >2 h was associated with a passing examination score (p < 0.001). Performance was not different based on increased years of surgical practice (p = 0.363), self-reported expertise on one or more types of energy-based devices (p = 0.683), participation in the FUSE postgraduate course (p = 0.426), or having reviewed the FUSE manual (p = 0.428). Logistic regression found that studying the FUSE didactics for >2 h predicted a passing score (OR 3.61; 95% CI 1.44-9.05; p = 0.006) independent of the other baseline characteristics recorded. The development of the FUSE examination, including the passing score, followed a psychometrically sound process. Self-reported time studying the FUSE curriculum predicted a passing score independent of other pretest characteristics such as years in practice and self-reported expertise.

  3. The statistical validity of nursing home survey findings.

    PubMed

    Woolley, Douglas C

    2011-11-01

    The Medicare nursing home survey is a high-stakes process whose findings greatly affect nursing homes, their current and potential residents, and the communities they serve. Therefore, survey findings must achieve high validity. This study looked at the validity of one key assessment made during a nursing home survey: the observation of the rate of errors in administration of medications to residents (med-pass). Statistical analysis of the case under study and of alternative hypothetical cases. A skilled nursing home affiliated with a local medical school. The nursing home administrators and the medical director. Observational study. The probability that state nursing home surveyors make a Type I or Type II error in observing med-pass error rates, based on the current case and on a series of postulated med-pass error rates. In the common situation such as our case, where med-pass errors occur at slightly above a 5% rate after 50 observations, and therefore trigger a citation, the chance that the true rate remains above 5% after a large number of observations is just above 50%. If the true med-pass error rate were as high as 10%, and the survey team wished to achieve 75% accuracy in determining that a citation was appropriate, they would have to make more than 200 med-pass observations. In the more common situation where med pass errors are closer to 5%, the team would have to observe more than 2000 med-passes to achieve even a modest 75% accuracy in their determinations. In settings where error rates are low, large numbers of observations of an activity must be made to reach acceptable validity of estimates for the true rates of errors. In observing key nursing home functions with current methodology, the State Medicare nursing home survey process does not adhere to well-known principles of valid error determination. Alternate approaches in survey methodology are discussed. Copyright © 2011 American Medical Directors Association. Published by Elsevier Inc. All rights reserved.

  4. Influence of poor effort on neuropsychological test performance in U.S. military personnel following mild traumatic brain injury.

    PubMed

    Lange, Rael T; Pancholi, Sonal; Bhagwat, Aditya; Anderson-Barnes, Victoria; French, Louis M

    2012-01-01

    The purpose of this study was to examine the influence of poor effort on neuropsychological test performance in military personnel following mild traumatic brain injury (MTBI). Participants were 143 U.S. service members who sustained a TBI, divided into three groups based on injury severity and performance on the Word Memory Test and four embedded markers of poor effort: MTBI-pass (n = 87), MTBI-fail (n = 21), and STBI-pass (n = 35; where STBI denotes severe TBI). Patients were evaluated at the Walter Reed Army Medical Center on average 3.9 months (SD = 3.4) post injury. The majority of the sample was Caucasian (84.6%), was male (93.0%), and had 12+ years of education (96.5%). Measures included the Personality Assessment Inventory (PAI) and 13 common neurocognitive measures. Patients in the MTBI-fail group performed worse on the majority of neurocognitive measures, followed by the Severe TBI-Pass group and the MTBI-pass group. Using a criterion of three or more low scores <10th percentile, the MTBI-fail group had the greatest rate of impairment (76.2%), followed by the Severe TBI-Pass group (34.3%) and MTBI-pass group (16.1%). On the PAI, the MTBI-fail group had higher scores on the majority of clinical scales (p < .05). There were a greater number of elevated scales (e.g., 5 or more elevated mild or higher) in the MTBI-fail group (71.4%) than in the MTBI-pass group (32.2%) and Severe TBI-Pass group (17.1%). Effort testing is an important component of postacute neuropsychological evaluations following combat-related MTBI. Those who fail effort testing are likely to be misdiagnosed as having severe cognitive impairment, and their symptom reporting is likely to be inaccurate.

  5. Development and psychometric properties of the Y-PASS questionnaire to assess correlates of lunchtime and after-school physical activity in children

    PubMed Central

    2014-01-01

    Background To frame interventions, it is useful to understand context- and time-specific correlates of children’s physical activity. To do this, we need accurate assessment of these correlates. There are currently no measures that assess correlates at all levels of the social ecological model, contain items that are specifically worded for the lunchtime and/or after-school time periods, and assess correlates that have been conceptualised and defined by children. The aim of this study was to develop and evaluate the psychometric properties of the lunchtime and after-school Youth Physical Activity Survey for Specific Settings (Y-PASS) questionnaires. Methods The Y-PASS questionnaire was administered to 264 South Australian children (146 boys, 118 girls; mean age = 11.7 ± 0.93 years). Factorial structure and internal consistency of the intrapersonal, sociocultural and physical environmental/policy lunchtime and after-school subscales were examined through an exploratory factor analysis. The test-retest reliability of the Y-PASS subscales was assessed over a one-week period on a subsample of children (lunchtime Y-PASS: n = 12 boys, 12 girls, mean age of 11.6 ± 0.8 years; after-school Y-PASS: n = 9 boys, 13 girls; mean age = 11.4 ± 0.9 years). Results For the lunchtime Y-PASS, three factors were identified under each of the intrapersonal, sociocultural and physical environmental/policy subscales. For the after-school Y-PASS, six factors were identified in the intrapersonal subscale, four factors in the sociocultural subscale and seven factors in the physical environmental/policy subscale. Following item reduction, all subscales demonstrated acceptable internal consistency (Cronbach alpha = 0.78 – 0.85), except for the lunchtime sociocultural subscale (Cronbach alpha = 0.55). The factors and items demonstrated fair to very high test-retest reliability (ICC = 0.26 – 0.93). Conclusion The preliminary reliability and factorial structure evidence suggests the Y-PASS correlate questionnaires are robust tools for measuring correlates of context-specific physical activity in children. The multi-dimensional factor structure provides justification for exploring physical activity correlates from a social ecological perspective and demonstrates the importance of developing items that are context specific. Further development and refinement of the Y-PASS questionnaires is recommended, including a confirmatory factor analysis and exploring the inclusion of additional items. PMID:24885601

  6. A feasibility study of reactor-based deep-burn concepts.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, T. K.; Taiwo, T. A.; Hill, R. N.

    2005-09-16

    A systematic assessment of the General Atomics (GA) proposed Deep-Burn concept based on the Modular Helium-Cooled Reactor design (DB-MHR) has been performed. Preliminary benchmarking of deterministic physics codes was done by comparing code results to those from MONTEBURNS (MCNP-ORIGEN) calculations. Detailed fuel cycle analyses were performed in order to provide an independent evaluation of the physics and transmutation performance of the one-pass and two-pass concepts. Key performance parameters such as transuranic consumption, reactor performance, and spent fuel characteristics were analyzed. This effort has been undertaken in close collaborations with the General Atomics design team and Brookhaven National Laboratory evaluation team.more » The study was performed primarily for a 600 MWt reference DB-MHR design having a power density of 4.7 MW/m{sup 3}. Based on parametric and sensitivity study, it was determined that the maximum burnup (TRU consumption) can be obtained using optimum values of 200 {micro}m and 20% for the fuel kernel diameter and fuel packing fraction, respectively. These values were retained for most of the one-pass and two-pass design calculations; variation to the packing fraction was necessary for the second stage of the two-pass concept. Using a four-batch fuel management scheme for the one-pass DB-MHR core, it was possible to obtain a TRU consumption of 58% and a cycle length of 286 EFPD. By increasing the core power to 800 MWt and the power density to 6.2 MW/m{sup 3}, it was possible to increase the TRU consumption to 60%, although the cycle length decreased by {approx}64 days. The higher TRU consumption (burnup) is due to the reduction of the in-core decay of fissile Pu-241 to Am-241 relative to fission, arising from the higher power density (specific power), which made the fuel more reactivity over time. It was also found that the TRU consumption can be improved by utilizing axial fuel shuffling or by operating with lower material temperatures (colder core). Results also showed that the transmutation performance of the one-pass deep-burn concept is sensitive to the initial TRU vector, primarily because longer cooling time reduces the fissile content (Pu-241 specifically.) With a cooling time of 5 years, the TRU consumption increases to 67%, while conversely, with 20-year cooling the TRU consumption is about 58%. For the two-pass DB-MHR (TRU recycling option), a fuel packing fraction of about 30% is required in the second pass (the recycled TRU). It was found that using a heterogeneous core (homogeneous fuel element) concept, the TRU consumption is dependent on the cooling interval before the 2nd pass, again due to Pu-241 decay during the time lag between the first pass fuel discharge and the second pass fuel charge. With a cooling interval of 7 years (5 and 2 years before and after reprocessing) a TRU consumption of 55% is obtained. With an assumed ''no cooling'' interval, the TRU consumption is 63%. By using a cylindrical core to reduce neutron leakage, TRU consumption of the case with 7-year cooling interval increases to 58%. For a two-pass concept using a heterogeneous fuel element (and homogeneous core) with first and second pass volume ratio of 2:1, the TRU consumption is 62.4%. Finally, the repository loading benefits arising from the deep-burn and Inert Matrix Fuel (IMF) concepts were estimated and compared, for the same initial TRU vector. The DB-MHR concept resulted in slightly higher TRU consumption and repository loading benefit compared to the IMF concept (58.1% versus 55.1% for TRU consumption and 2.0 versus 1.6 for estimated repository loading benefit).« less

  7. On the generalizability of the Chunk-and-Pass processing approach: Perspectives from language acquisition and music.

    PubMed

    Lakshmanan, Usha; Graham, Robert E

    2016-01-01

    Christiansen & Chater (C&C) offer the Chunk-and-Pass strategy as a language processing approach allowing humans to make sense of incoming language in the face of cognitive and perceptual constraints. We propose that the Chunk-and-Pass strategy is not adequate to extend universally across languages (accounting for typologically diverse languages), nor is it sufficient to generalize to other auditory modalities such as music.

  8. A Statistical Comparison of First Time Praxis II Pass Rates between Homegrown 4 Year Students and Transfer Students of a Medium Size Suburban University: A Six Year Study

    ERIC Educational Resources Information Center

    Holmes, Jason Edward, Jr.

    2011-01-01

    In order to meet the federal mandate specified by the No Child Left Behind Act to demonstrate content competency for teaching certification, students must pass a written examination. Missouri and 37 other states chose the Praxis II to satisfy requirements. Presently, schools of education advertise the passing rate of the Praxis II as 100%, since…

  9. Analysis of Microstructure Refinement During Single-Pass and Multi-Pass Friction Stir Processing of Nial Propeller Bronze

    DTIC Science & Technology

    2010-09-01

    on an Optical Micrograph of the Transverse View of Single-Pass NAB. After [5]............................................... 6 Figure 4 . Vertical...deformed and 6 elongated but does not see the same refinement that is seen inside the SZ [ 4 ]. The grain structure right outside the TMAZ will also...including grinding, polishing, and electropolishing . The first step was to grind the surface using a Buehler ECOMET 4 Variable Speed Grinder

  10. The Thurgood Marshall School of Law Empirical Findings: A Report of the Correlational Analysis of Bar Passing Rates and Final GPA of Years 2005-2009

    ERIC Educational Resources Information Center

    Kadhi, T.; Holley, D.; Palasota, A.; Garrison, P.; Green, T.

    2010-01-01

    The following analysis was done to investigate the findings of the Correlational Relationship (R) between the Bar Passing Rates and GPAs of the Years 2005-2009. This report of findings was done to see if there are any significant relationships between the three variables (Bar Pass/Fail/Unknown, Overall GPA, and Bar GPA). The following procedures…

  11. Verification of Faulty Message Passing Systems with Continuous State Space in PVS

    NASA Technical Reports Server (NTRS)

    Pilotto, Concetta; White, Jerome

    2010-01-01

    We present a library of Prototype Verification System (PVS) meta-theories that verifies a class of distributed systems in which agent commu nication is through message-passing. The theoretic work, outlined in, consists of iterative schemes for solving systems of linear equations , such as message-passing extensions of the Gauss and Gauss-Seidel me thods. We briefly review that work and discuss the challenges in formally verifying it.

  12. 33 CFR 110.195 - Mississippi River below Baton Rouge, LA, including South and Southwest Passes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... river from mile 1.5 to mile 6.7 above Head of Passes, extending in width to 1600 feet from the left... along the left descending bank of the river from mile 8.0 to mile 9.6 above Head of Passes with the west... Venice Anchorage. An area 1.2 miles in length along the left descending bank of the river from mile 10.0...

  13. 33 CFR 110.195 - Mississippi River below Baton Rouge, LA, including South and Southwest Passes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... river from mile 1.5 to mile 6.7 above Head of Passes, extending in width to 1600 feet from the left... along the left descending bank of the river from mile 8.0 to mile 9.6 above Head of Passes with the west... Venice Anchorage. An area 1.2 miles in length along the left descending bank of the river from mile 10.0...

  14. Space Shuttle Program Primary Avionics Software System (PASS) Success Legacy - Major Accomplishments and Lessons Learned Detail Historical Timeline Analysis

    NASA Technical Reports Server (NTRS)

    Orr, James K.

    2010-01-01

    This presentation focuses on the Space Shuttle Primary Avionics Software System (PASS) and the people who developed and maintained this system. One theme is to provide quantitative data on software quality and reliability over a 30 year period. Consistent data relates to code break discrepancies. Requirements were supplied from external sources. Requirement inspections and measurements not implemented until later, beginning in 1985. Second theme is to focus on the people and organization of PASS. Many individuals have supported the PASS project over the entire period while transitioning from company to company and contract to contract. Major events and transitions have impacted morale (both positively and negatively) across the life of the project.

  15. LEACHING OF URANIUM ORES USING ALKALINE CARBONATES AND BICARBONATES AT ATMOSPHERIC PRESSURE

    DOEpatents

    Thunaes, A.; Brown, E.A.; Rabbits, A.T.; Simard, R.; Herbst, H.J.

    1961-07-18

    A method of leaching uranium ores containing sulfides is described. The method consists of adding a leach solution containing alkaline carbonate and alkaline bicarbonate to the ore to form a slurry, passing the slurry through a series of agitators, passing an oxygen containing gas through the slurry in the last agitator in the series, passing the same gas enriched with carbon dioxide formed by the decomposition of bicarbonates in the slurry through the penultimate agitator and in the same manner passing the same gas increasingly enriched with carbon dioxide through the other agitators in the series. The conditions of agitation is such that the extraction of the uranium content will be substantially complete before the slurry reaches the last agitator.

  16. Single-pass incremental force updates for adaptively restrained molecular dynamics.

    PubMed

    Singh, Krishna Kant; Redon, Stephane

    2018-03-30

    Adaptively restrained molecular dynamics (ARMD) allows users to perform more integration steps in wall-clock time by switching on and off positional degrees of freedoms. This article presents new, single-pass incremental force updates algorithms to efficiently simulate a system using ARMD. We assessed different algorithms for speedup measurements and implemented them in the LAMMPS MD package. We validated the single-pass incremental force update algorithm on four different benchmarks using diverse pair potentials. The proposed algorithm allows us to perform simulation of a system faster than traditional MD in both NVE and NVT ensembles. Moreover, ARMD using the new single-pass algorithm speeds up the convergence of observables in wall-clock time. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  17. Fish pass assessment by remote control: a novel framework for quantifying the hydraulics at fish pass entrances

    NASA Astrophysics Data System (ADS)

    Kriechbaumer, Thomas; Blackburn, Kim; Gill, Andrew; Breckon, Toby; Everard, Nick; Wright, Ros; Rivas Casado, Monica

    2014-05-01

    Fragmentation of aquatic habitats can lead to the extinction of migratory fish species with severe negative consequences at the ecosystem level and thus opposes the target of good ecological status of rivers defined in the EU Water Framework Directive (WFD). In the UK, the implementation of the EU WFD requires investments in fish pass facilities of estimated 532 million GBP (i.e. 639 million Euros) until 2027 to ensure fish passage at around 3,000 barriers considered critical. Hundreds of passes have been installed in the past. However, monitoring studies of fish passes around the world indicate that on average less than half of the fish attempting to pass such facilities are actually successful. There is a need for frameworks that allow the rapid identification of facilities that are biologically effective and those that require enhancement. Although there are many environmental characteristics that can affect fish passage success, past research suggests that variations in hydrodynamic conditions, reflected in water velocities, velocity gradients and turbulences, are the major cues that fish use to seek migration pathways in rivers. This paper presents the first steps taken in the development of a framework for the rapid field-based quantification of the hydraulic conditions downstream of fish passes and the assessment of the attractivity of fish passes for salmonids and coarse fish in UK rivers. For this purpose, a small-sized remote control platform carrying an acoustic Doppler current profiler (ADCP), a GPS unit, a stereo camera and an inertial measurement unit has been developed. The large amount of data on water velocities and depths measured by the ADCP within relatively short time is used to quantify the spatial and temporal distribution of water velocities. By matching these hydraulic features with known preferences of migratory fish, it is attempted to identify likely migration routes and aggregation areas at barriers as well as hydraulic features that may distract fish away from fish pass entrances. The initial steps of the framework development have focused on the challenge of precise spatial data referencing in areas with limited sky view to navigation satellites. Platform tracking with a motorised Total Station, various satellite-based positioning solutions and simultaneous localisation and mapping (SLAM) based on stereo images have been tested. The effect of errors in spatial data referencing on ADCP-derived maps of flow features and bathymetry will be quantified through simultaneous deployment of these navigation technologies and the ADCP. This will inform the selection of a cost-effective platform positioning system in practice. Further steps will cover the quantification of uncertainties in ADCP data caused by highly turbulent flows and the identification of suitable ADCP data sampling strategies at fish passes. The final framework for fish pass assessment can contribute to an improved understanding of the interaction of fish and the complex hydraulic river environment.

  18. Community Petascale Project for Accelerator Science and Simulation: Advancing Computational Science for Future Accelerators and Accelerator Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spentzouris, P.; /Fermilab; Cary, J.

    The design and performance optimization of particle accelerators are essential for the success of the DOE scientific program in the next decade. Particle accelerators are very complex systems whose accurate description involves a large number of degrees of freedom and requires the inclusion of many physics processes. Building on the success of the SciDAC-1 Accelerator Science and Technology project, the SciDAC-2 Community Petascale Project for Accelerator Science and Simulation (ComPASS) is developing a comprehensive set of interoperable components for beam dynamics, electromagnetics, electron cooling, and laser/plasma acceleration modelling. ComPASS is providing accelerator scientists the tools required to enable the necessarymore » accelerator simulation paradigm shift from high-fidelity single physics process modeling (covered under SciDAC1) to high-fidelity multiphysics modeling. Our computational frameworks have been used to model the behavior of a large number of accelerators and accelerator R&D experiments, assisting both their design and performance optimization. As parallel computational applications, the ComPASS codes have been shown to make effective use of thousands of processors. ComPASS is in the first year of executing its plan to develop the next-generation HPC accelerator modeling tools. ComPASS aims to develop an integrated simulation environment that will utilize existing and new accelerator physics modules with petascale capabilities, by employing modern computing and solver technologies. The ComPASS vision is to deliver to accelerator scientists a virtual accelerator and virtual prototyping modeling environment, with the necessary multiphysics, multiscale capabilities. The plan for this development includes delivering accelerator modeling applications appropriate for each stage of the ComPASS software evolution. Such applications are already being used to address challenging problems in accelerator design and optimization. The ComPASS organization for software development and applications accounts for the natural domain areas (beam dynamics, electromagnetics, and advanced acceleration), and all areas depend on the enabling technologies activities, such as solvers and component technology, to deliver the desired performance and integrated simulation environment. The ComPASS applications focus on computationally challenging problems important for design or performance optimization to all major HEP, NP, and BES accelerator facilities. With the cost and complexity of particle accelerators rising, the use of computation to optimize their designs and find improved operating regimes becomes essential, potentially leading to significant cost savings with modest investment.« less

  19. A Regional Survey of River-plume Sedimentation on the Mississippi River Delta Front

    NASA Astrophysics Data System (ADS)

    Courtois, A. J.; Bentley, S. J.; Xu, K.; Georgiou, I. Y.; Maloney, J. M.; Miner, M. D.; Chaytor, J. D.; Smith, J.

    2017-12-01

    Many studies of the Mississippi River and Delta (MRD) have shown historic declines in sediment load reaching the main river distributaries over the last few decades. Recent studies also reported that 50% of the suspended load during floods is sequestered within the delta. While the impact of declining sediment load on wetland loss is well documented, submarine sedimentary processes on the delta front during this recent period of declining sediment load are understudied. To better understand modern sediment dispersal and deposition across the Mississippi River Delta Front, 31 multicores were collected in June 2017 from locations extending offshore from Southwest Pass, South Pass, and Pass a Loutre (the main river outlets) in water depths of 25-280 m. Core locations were selected based on multibeam bathymetry and morphology collected by the USGS in May 2017; the timing of collection coincided with the end of annual peak discharge on the Mississippi River. This multi-agency survey is the first to study delta-front sedimentary processes regionally with such a wide suite of tools. Target locations for coring included the dominant depositional environments: mudflow lobes, gullies, and undisturbed prodelta. Cores were subsampled at 2 cm intervals and analyzed for Beryllium-7 activity via gamma spectrometry; in such settings, Be-7 can be used as a tracer of sediment recently delivered from fluvial origin. Results indicate a general trend of declining Be-7 activity with increasing distance from source, and in deeper water. Inshore samples near Southwest Pass show the deepest penetration depth of Be-7 into the sediment (24-26 cm), which is a preliminary indicator of rapid seasonal sedimentation. Nearshore samples from South Pass exhibited similar Be-7 penetration depths, with results near Pass a Loutre to 14-16 cm depth. Be-7 remains detectable to 2 cm in water 206 m deep, approximately 20 km from South Pass. Sediment dispersal remains impressive offshore from all three major river outlets, despite overall decline of sediment load in recent decades, and pronounced declines for South Pass and Pass a Loutre. Future research will focus on relationships among changing sediment loads, dispersal patterns, and sediment transport by mudflows, which are an important process for dispersal after initial deposition.

  20. Development of a reliable simulation-based test for diagnostic abdominal ultrasound with a pass/fail standard usable for mastery learning.

    PubMed

    Østergaard, Mia L; Nielsen, Kristina R; Albrecht-Beste, Elisabeth; Konge, Lars; Nielsen, Michael B

    2018-01-01

    This study aimed to develop a test with validity evidence for abdominal diagnostic ultrasound with a pass/fail-standard to facilitate mastery learning. The simulator had 150 real-life patient abdominal scans of which 15 cases with 44 findings were selected, representing level 1 from The European Federation of Societies for Ultrasound in Medicine and Biology. Four groups of experience levels were constructed: Novices (medical students), trainees (first-year radiology residents), intermediates (third- to fourth-year radiology residents) and advanced (physicians with ultrasound fellowship). Participants were tested in a standardized setup and scored by two blinded reviewers prior to an item analysis. The item analysis excluded 14 diagnoses. Both internal consistency (Cronbach's alpha 0.96) and inter-rater reliability (0.99) were good and there were statistically significant differences (p < 0.001) between all four groups, except the intermediate and advanced groups (p = 1.0). There was a statistically significant correlation between experience and test scores (Pearson's r = 0.82, p < 0.001). The pass/fail-standard failed all novices (no false positives) and passed all advanced (no false negatives). All intermediate participants and six out of 14 trainees passed. We developed a test for diagnostic abdominal ultrasound with solid validity evidence and a pass/fail-standard without any false-positive or false-negative scores. • Ultrasound training can benefit from competency-based education based on reliable tests. • This simulation-based test can differentiate between competency levels of ultrasound examiners. • This test is suitable for competency-based education, e.g. mastery learning. • We provide a pass/fail standard without false-negative or false-positive scores.

  1. Factors Associated with First-Pass Success in Pediatric Intubation in the Emergency Department.

    PubMed

    Goto, Tadahiro; Gibo, Koichiro; Hagiwara, Yusuke; Okubo, Masashi; Brown, David F M; Brown, Calvin A; Hasegawa, Kohei

    2016-03-01

    The objective of this study was to investigate the factors associated with first-pass success in pediatric intubation in the emergency department (ED). We analyzed the data from two multicenter prospective studies of ED intubation in 17 EDs between April 2010 and September 2014. The studies prospectively measured patient's age, sex, principal indication for intubation, methods (e.g., rapid sequence intubation [RSI]), devices, and intubator's level of training and specialty. To evaluate independent predictors of first-pass success, we fit logistic regression model with generalized estimating equations. In the sensitivity analysis, we repeated the analysis in children <10 years. A total of 293 children aged ≤18 years who underwent ED intubation were eligible for the analysis. The overall first-pass success rate was 60% (95%CI [54%-66%]). In the multivariable model, age ≥10 years (adjusted odds ratio [aOR], 2.45; 95% CI [1.23-4.87]), use of RSI (aOR, 2.17; 95% CI [1.31-3.57]), and intubation attempt by an emergency physician (aOR, 3.21; 95% CI [1.78-5.83]) were significantly associated with a higher chance of first-pass success. Likewise, in the sensitivity analysis, the use of RSI (aOR, 3.05; 95% CI [1.63-5.70]), and intubation attempt by an emergency physician (aOR, 4.08; 95% CI [1.92-8.63]) were significantly associated with a higher chance of first-pass success. Based on two large multicenter prospective studies of ED airway management, we found that older age, use of RSI, and intubation by emergency physicians were the independent predictors of a higher chance of first-pass success in children. Our findings should facilitate investigations to develop optimal airway management strategies in critically-ill children in the ED.

  2. Imaging Spectrometer on a Chip

    NASA Technical Reports Server (NTRS)

    Wang, Yu; Pain, Bedabrata; Cunningham, Thomas; Zheng, Xinyu

    2007-01-01

    A proposed visible-light imaging spectrometer on a chip would be based on the concept of a heterostructure comprising multiple layers of silicon-based photodetectors interspersed with long-wavelength-pass optical filters. In a typical application, this heterostructure would be replicated in each pixel of an image-detecting integrated circuit of the active-pixel-sensor type (see figure). The design of the heterostructure would exploit the fact that within the visible portion of the spectrum, the characteristic depth of penetration of photons increases with wavelength. Proceeding from the front toward the back, each successive long-wavelength-pass filter would have a longer cutoff wavelength, and each successive photodetector would be made thicker to enable it to absorb a greater proportion of incident longer-wavelength photons. Incident light would pass through the first photodetector and encounter the first filter, which would reflect light having wavelengths shorter than its cutoff wavelength and pass light of longer wavelengths. A large portion of the incident and reflected shorter-wavelength light would be absorbed in the first photodetector. The light that had passed through the first photodetector/filter pair of layers would pass through the second photodetector and encounter the second filter, which would reflect light having wavelengths shorter than its cutoff wavelength while passing light of longer wavelengths. Thus, most of the light reflected by the second filter would lie in the wavelength band between the cutoff wavelengths of the first and second filters. Thus, further, most of the light absorbed in the second photodetector would lie in this wavelength band. In a similar manner, each successive photodetector would detect, predominantly, light in a successively longer wavelength band bounded by the shorter cutoff wavelength of the preceding filter and the longer cutoff wavelength of the following filter.

  3. The American Board of Internal Medicine Maintenance of Certification Examination and State Medical Board Disciplinary Actions: a Population Cohort Study.

    PubMed

    McDonald, Furman S; Duhigg, Lauren M; Arnold, Gerald K; Hafer, Ruth M; Lipner, Rebecca S

    2018-03-07

    Some have questioned whether successful performance in the American Board of Internal Medicine (ABIM) Maintenance of Certification (MOC) program is meaningful. The association of the ABIM Internal Medicine (IM) MOC examination with state medical board disciplinary actions is unknown. To assess risk of disciplinary actions among general internists who did and did not pass the MOC examination within 10 years of initial certification. Historical population cohort study. The population of internists certified in internal medicine, but not a subspecialty, from 1990 through 2003 (n = 47,971). ABIM IM MOC examination. General internal medicine in the USA. The primary outcome measure was time to disciplinary action assessed in association with whether the physician passed the ABIM IM MOC examination within 10 years of initial certification, adjusted for training, certification, demographic, and regulatory variables including state medical board Continuing Medical Education (CME) requirements. The risk for discipline among physicians who did not pass the IM MOC examination within the 10 year requirement window was more than double than that of those who did pass the examination (adjusted HR 2.09; 95% CI, 1.83 to 2.39). Disciplinary actions did not vary by state CME requirements (adjusted HR 1.02; 95% CI, 0.94 to 1.16), but declined with increasing MOC examination scores (Kendall's tau-b coefficient = - 0.98 for trend, p < 0.001). Among disciplined physicians, actions were less severe among those passing the IM MOC examination within the 10-year requirement window than among those who did not pass the examination. Passing a periodic assessment of medical knowledge is associated with decreased state medical board disciplinary actions, an important quality outcome of relevance to patients and the profession.

  4. Subcutaneous ICD screening with the Boston Scientific ZOOM programmer versus a 12-lead ECG machine.

    PubMed

    Chang, Shu C; Patton, Kristen K; Robinson, Melissa R; Poole, Jeanne E; Prutkin, Jordan M

    2018-02-24

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) requires preimplant screening to ensure appropriate sensing and reduce risk of inappropriate shocks. Screening can be performed using either an ICD programmer or a 12-lead electrocardiogram (ECG) machine. It is unclear whether differences in signal filtering and digital sampling change the screening success rate. Subjects were recruited if they had a transvenous single-lead ICD without pacing requirements or were candidates for a new ICD. Screening was performed using both a Boston Scientific ZOOM programmer (Marlborough, MA, USA) and General Electric MAC 5000 ECG machine (Fairfield, CT, USA). A pass was defined as having at least one lead that fit within the screening template in both supine and sitting positions. A total of 69 subjects were included and 27 sets of ECG leads had differing screening results between the two machines (7%). Of these sets, 22 (81%) passed using the ECG machine but failed using the programmer and five (19%) passed using the ECG machine but failed using the programmer (P < 0.001). Four subjects (6%) passed screening using the ECG machine but failed using the programmer. No subject passed screening with the programmer but failed with the ECG machine. There can be occasional disagreement in S-ICD patient screening between an ICD programmer and ECG machine, all of whom passed with the ECG machine but failed using the programmer. On a per lead basis, the ECG machine passes more subjects. It is unknown what the inappropriate shock rate would be if an S-ICD was implanted. Clinical judgment should be used in borderline cases. © 2018 Wiley Periodicals, Inc.

  5. The Effect of Cu Powder During Friction Stir Welding on Microstructure and Mechanical Properties of AA3003-H18

    NASA Astrophysics Data System (ADS)

    Abnar, B.; Kazeminezhad, M.; Kokabi, A. H.

    2014-08-01

    Friction stir welding (FSW) was used to join 3003-H18 non-heat-treatable aluminum alloy plates by adding copper powder. The copper powder was first added to the gap (0.1 and 0.2 mm) between two plates and then the FSW was performed. The specimens were joined at various rotational speeds of 800, 1000, and 1200 rpm at traveling speeds of 70 and 100 mm/min. The effects of rotational speed, second pass of FSW, and direction of second pass also were studied on copper particle distribution and formation of Al-Cu intermetallic compounds in the stir zone. The second pass of FSW was carried out in two ways; in line with the first pass direction (2F) and in the reverse direction of the first pass (FB). The microstructure, mechanical properties, and formation of intermetallic compounds type were investigated. In high copper powder compaction into the gap, large clusters were formed in the stir zone, while fine clusters and sound copper particles distribution were obtained in low powder compaction. The copper particle distribution and amount of Al-Cu intermetallic compounds were increased in the stir zone with increasing the rotational speed and applying the second pass. Al2Cu and AlCu intermetallic phases were formed in the stir zone and consequently the hardness was significantly increased. The copper particles and in situ intermetallic compounds were symmetrically distributed in both advancing and retreating sides of weld zone after FB passes. Thus, the wider area was reinforced by the intermetallic compounds. Also, the tensile test specimens tend to fracture from the coarse copper aggregation at the low rotational speeds. At high rotational speeds, the fracture locations are placed in HAZ and TMAZ.

  6. A pilot study of EUS-guided through-the-needle forceps biopsy (with video).

    PubMed

    Nakai, Yousuke; Isayama, Hiroyuki; Chang, Kenneth J; Yamamoto, Natsuyo; Mizuno, Suguru; Mohri, Dai; Kogure, Hirofumi; Matsubara, Saburo; Tada, Minoru; Koike, Kazuhiko

    2016-07-01

    In EUS-guided FNA (EUS-FNA), small-caliber needles are preferable for optimal cytologic yield, whereas large ones are preferable when histologic specimens are needed. Because of the rigidity and friction induced by its large caliber, however, technical limitation does exist in a 19-gauge FNA needle. Recent development of miniature biopsy forceps enables EUS-guided through-the-needle forceps biopsy (EUS-TTNFB). The aim of this study is to evaluate safety and efficacy of EUS-TTNFB. Eighteen sessions of EUS-TTNFB in 17 patients with solid lesions were performed by using a 0.75-mm biopsy forceps through a 19-gauge FNA needle. Technical feasibility, safety, and diagnostic yield of EUS-TTNFB were retrospectively studied. A total of 49 passes, a median of 3 passes per session, were performed, and the needle puncture, advancement and removal of the biopsy forceps, and subsequent EUS-FNA were technically successful in all patients. No adverse events were observed other than one case with hyperamylasemia without pancreatitis. Macroscopic histologic core by EUS-TTNFB was obtained at a rate of 71% per pass. The tissue acquisition rate by EUS-TTNFB alone was 67% per pass and 100% per session. When EUS-TTNFB and subsequent EUS-FNA were combined, the tissue acquisition rate was 94% per pass. The accuracy of combined EUS-TTNFB and EUS-FNA to diagnose malignancy was 88% per pass and 94% per session. With a single pass of EUS-TTNFB and EUS-FNA, the tissue acquisition rate was 89%, and the accuracy to diagnose malignancy was 83%. EUS-TTNFB was safe and technically feasible and provided additional tissue acquisition with a single puncture of a 19-gauge FNA needle. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. A low-dose, dual-phase cardiovascular CT protocol to assess left atrial appendage anatomy and exclude thrombus prior to left atrial intervention.

    PubMed

    Lazoura, Olga; Ismail, Tevfik F; Pavitt, Christopher; Lindsay, Alistair; Sriharan, Mona; Rubens, Michael; Padley, Simon; Duncan, Alison; Wong, Tom; Nicol, Edward

    2016-02-01

    Assessment of the left atrial appendage (LAA) for thrombus and anatomy is important prior to atrial fibrillation (AF) ablation and LAA exclusion. The use of cardiovascular CT (CCT) to detect LAA thrombus has been limited by the high incidence of pseudothrombus on single-pass studies. We evaluated the diagnostic accuracy of a two-phase protocol incorporating a limited low-dose delayed contrast-enhanced examination of the LAA, compared with a single-pass study for LAA morphological assessment, and transesophageal echocardiography (TEE) for the exclusion of thrombus. Consecutive patients (n = 122) undergoing left atrial interventions for AF were assessed. All had a two-phase CCT protocol (first-past scan plus a limited, 60-s delayed scan of the LAA) and TEE. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) were calculated for the detection of true thrombus on first-pass and delayed scans, using TEE as the gold standard. Overall, 20/122 (16.4 %) patients had filling defects on the first-pass study. All affected the full delineation of the LAA morphology; 17/20 (85 %) were confirmed as pseudo-filling defects. Three (15 %) were seen on late-pass and confirmed as true thrombi on TEE; a significant improvement in diagnostic performance relative to a single-pass scan (McNemar Chi-square 17, p < 0.001). The sensitivity, specificity, diagnostic accuracy, PPV and NPV was 100, 85.7, 86.1, 15.0 and 100 % respectively for first-pass scans, and 100 % for all parameters for the delayed scans. The median (range) additional radiation dose for the delayed scan was 0.4 (0.2-0.6) mSv. A low-dose delayed scan significantly improves the identification of true LAA anatomy and thrombus in patients undergoing LA intervention.

  8. Clinical utility of the Conners' Continuous Performance Test-II to detect poor effort in U.S. military personnel following traumatic brain injury.

    PubMed

    Lange, Rael T; Iverson, Grant L; Brickell, Tracey A; Staver, Tara; Pancholi, Sonal; Bhagwat, Aditya; French, Louis M

    2013-06-01

    The purpose of this study is to examine the clinical utility of the Conners' Continuous Performance Test (CPT-II) as an embedded marker of poor effort in military personnel undergoing neuropsychological evaluations following traumatic brain injury. Participants were 158 U.S. military service members divided into 3 groups on the basis of brain injury severity and performance (pass/fail) on 2 symptom validity tests: Mild Traumatic Brain Injury (MTBI)-Pass (n = 87), MTBI-Fail (n = 42), and severe traumatic brain injury (STBI)-Pass (n = 29). The MTBI-Fail group performed worse on the majority of CPT-II measures compared with both the MTBI-Pass and STBI-Pass groups. When comparing the MTBI-Fail group and MTBI-Pass groups, the most accurate measure for identifying poor effort was the Commission T score. When selected measures were combined (i.e., Omissions, Commissions, and Perseverations), there was a very small increase in sensitivity (from .26 to .29). When comparing the MTBI-Fail group and STBI-Pass groups, the most accurate measure for identifying poor effort was the Omission and Commissions T score. When selected measures were combined, sensitivity again increased (from .24 to .45). Overall, these results suggest that individual CPT-II measures can be useful for identifying people who are suspected of providing poor effort from those who have provided adequate effort. However, due to low sensitivity and modest negative predictive power values, this measure cannot be used in isolation to detect poor effort, and is largely useful as a test to "rule in," not "rule out" poor effort. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  9. Pore pressure may control rupture propagation of the 2001 Mw=7.8 Kokoxili earthquake from the Kunlun fault to the Kunlun Pass fault

    NASA Astrophysics Data System (ADS)

    Xiao, J.; Wang, W.; He, J.

    2016-12-01

    The 2001 Mw=7.8 Kokoxili earthquake nucleated on the west-east tending Kunlun strike-slip fault in center of the Tibetan plateau. When the rupture propagated eastward near the Xidatan segment of the Kunlun fault, this earthquake jumped to the Kunlun Pass fault, a less matured fault that, due to the geometric orientation, was obviously clamped by the coseismic deformation before its rupture. To investigate the possible mechanism for the rupture jump, we updated the coseismic rupture model from a joint inversion of the geological, geodetic and seismic wave data. Constrained with the rupture process, a three-dimensional finite element model was developed to calculate the failure stress from elastic and poroelastic deformation of the crust during the rupture propagation. Results show that just before the rupture reached the conjunction of the Xidatan segment and the Kunlun Pass fault, the failure stress induced by elastic deformation is indeed larger on Xidatan segment of the Kunlun fault than on the Kunlun Pass fault. However, if the pore pressure resulted from undrained poroelastic deformation was invoked, the failure stress is significantly increased on the Kunlun Pass fault. Given a reasonable bound on fault friction and on poroelastic parameters, it can be seen that the poroelastic failure stress is 0.3-0.9 Mpa greater on the Kunlun Pass fault than on Xidatan segment of the Kunlun fault. We therefore argue that during the rupture process of the 2001 Mw=7.8 Kokoxili earthquake, pore pressure may play an important role on controlling the rupture propagation from the Kunlun fault to the Kunlun Pass fault.

  10. Prehospital Acute Stroke Severity Scale to Predict Large Artery Occlusion: Design and Comparison With Other Scales.

    PubMed

    Hastrup, Sidsel; Damgaard, Dorte; Johnsen, Søren Paaske; Andersen, Grethe

    2016-07-01

    We designed and validated a simple prehospital stroke scale to identify emergent large vessel occlusion (ELVO) in patients with acute ischemic stroke and compared the scale to other published scales for prediction of ELVO. A national historical test cohort of 3127 patients with information on intracranial vessel status (angiography) before reperfusion therapy was identified. National Institutes of Health Stroke Scale (NIHSS) items with the highest predictive value of occlusion of a large intracranial artery were identified, and the most optimal combination meeting predefined criteria to ensure usefulness in the prehospital phase was determined. The predictive performance of Prehospital Acute Stroke Severity (PASS) scale was compared with other published scales for ELVO. The PASS scale was composed of 3 NIHSS scores: level of consciousness (month/age), gaze palsy/deviation, and arm weakness. In derivation of PASS 2/3 of the test cohort was used and showed accuracy (area under the curve) of 0.76 for detecting large arterial occlusion. Optimal cut point ≥2 abnormal scores showed: sensitivity=0.66 (95% CI, 0.62-0.69), specificity=0.83 (0.81-0.85), and area under the curve=0.74 (0.72-0.76). Validation on 1/3 of the test cohort showed similar performance. Patients with a large artery occlusion on angiography with PASS ≥2 had a median NIHSS score of 17 (interquartile range=6) as opposed to PASS <2 with a median NIHSS score of 6 (interquartile range=5). The PASS scale showed equal performance although more simple when compared with other scales predicting ELVO. The PASS scale is simple and has promising accuracy for prediction of ELVO in the field. © 2016 American Heart Association, Inc.

  11. Performance of single-pass and by-pass multi-step multi-soil-layering systems for low-(C/N)-ratio polluted river water treatment.

    PubMed

    Wei, Cai-Jie; Wu, Wei-Zhong

    2018-09-01

    Two kinds of hybrid two-step multi-soil-layering (MSL) systems loaded with different filter medias (zeolite-ceramsite MSL-1 and ceramsite-red clay MSL-2) were set-up for the low-(C/N)-ratio polluted river water treatment. A long-term pollutant removal performance of these two kinds of MSL systems was evaluated for 214 days. By-pass was employed in MSL systems to evaluate its effect on nitrogen removal enhancement. Zeolite-ceramsite single-pass MSL-1 system owns outstanding ammonia removal capability (24 g NH 4 + -Nm -2 d -1 ), 3 times higher than MSL-2 without zeolite under low aeration rate condition (0.8 × 10 4  L m -2 .h -1 ). Aeration rate up to 1.6 × 10 4  L m -2 .h -1 well satisfied the requirement of complete nitrification in first unit of both two MSLs. However, weak denitrification in second unit was commonly observed. By-pass of 50% influent into second unit can improve about 20% TN removal rate for both MSL-1 and MSL-2. Complete nitrification and denitrification was achieved in by-pass MSL systems after addition of carbon source with the resulting C/N ratio up to 2.5. The characters of biofilms distributed in different sections inside MSL-1 system well illustrated the nitrogen removal mechanism inside MSL systems. Two kinds of MSLs are both promising as an appealing nitrifying biofilm reactor. Recirculation can be considered further for by-pass MSL-2 system to ensure a complete ammonia removal. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Serpentine Ultralong Path with Extended Routing (SUPER) High Resolution Traveling Wave Ion Mobility-MS using Structures for Lossless Ion Manipulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Liulin; Webb, Ian K.; Garimella, Sandilya V. B.

    Ion mobility (IM) separations have a broad range of analytical applications, but insufficient resolution limits many applications. Here we report on traveling wave (TW) ion mobility (IM) separations in a Serpentine Ultra-long Path with Extended Routing (SUPER) Structures for Lossless Ion Manipulations (SLIM) module in conjunction with mass spectrometry (MS). The extended routing utilized multiple passes was facilitated by the introduction of a lossless ion switch at the end of the ion path that either directed ions to the MS detector or to another pass through the serpentine separation region, providing theoretically unlimited TWIM path lengths. Ions were confined inmore » the SLIM by rf fields in conjunction with a DC guard bias, enabling essentially lossless TW transmission over greatly extended paths (e.g., ~1094 meters over 81 passes through the 13.5 m serpentine path). In this multi-pass SUPER TWIM provided resolution approximately proportional to the square root of the number of passes (or path length). More than 30-fold higher IM resolution for Agilent tuning mix m/z 622 and 922 ions (~340 vs. ~10) was achieved for 40 passes compared to commercially available drift tube IM and other TWIM-based platforms. An initial evaluation of the isomeric sugars Lacto-N-hexaose and Lacto-N-neohexaose showed the isomeric structures to be baseline resolved, and a new conformational feature for Lacto-N-neohexaose was revealed after 9 passes. The new SLIM SUPER high resolution TWIM platform has broad utility in conjunction with MS and is expected to enable a broad range of previously challenging or intractable separations.« less

  13. Association between EMS Question Bank Completion and Passing Rates on the EMS Certification Examination.

    PubMed

    Clemency, Brian; Martin-Gill, Christian; Rall, Nicole; May, Paul; Lubin, Jeffrey; Cooley, Craig; Van Dillen, Christine; Silvestri, Salvatore; Portela, Roberto; Cooney, Derek; Knutsen, Christian; March, Juan

    2017-01-01

    A board review question bank was created to assist candidates in their preparation for the 2015 EMS certification examination. We aimed to describe the development of this question bank and evaluate its successes in preparing candidates to obtain EMS subspecialty board certification. An online question bank was developed by 13 subject matter experts who participated as item writers, representing eight different EMS fellowship programs. The online question bank consisted of four practice tests, with each of the tests comprised of 100 questions. The number of candidates who participated in and completed the question bank was calculated. The passing rate among candidates who completed the question bank was calculated and compared to the publicly reported statistics for all candidates. The relationship between candidates' performance on the question bank and subspecialty exam pass rates was determined. A total of 252 candidates took at least one practice test and, of those, 225 candidates completed all four 100-question practice tests. The pass rate on the 2015 EMS certification exam was 79% (95%CI 74-85%) among candidates who completed the question bank, which is 12% higher than the overall pass rate (p = 0.003). Candidates' performance on the question bank was positively associated with overall success on the exam (X 2 = 75.8, p < 0.0001). Achieving a score of ≥ 70% on the question bank was associated with a higher likelihood of passing the exam (OR = 17.8; 95% CI: 8.0-39.6). Completing the question bank program was associated with improved pass rates on the EMS certification exam. Strong performance on the question bank correlated with success on the exam.

  14. Sources of Conflict in the Middle East - The Haves and Have Nots

    DTIC Science & Technology

    1993-04-01

    aircraft passed over the pyramids of Giza . From the air they were awe inspiring symbols of a great civilization. Landing at Cairo’s international...airport, we passed through a sargasso sea of bureaucracy and boarded a bus for a trip to those same pyramids . On the way we passed through the city of...time next to absolute poverty stood magnificent palaces, luxurious hotels and imposing government edifices. Arriving at the pyramids , we were

  15. Spectrometer capillary vessel and method of making same

    DOEpatents

    Linehan, John C.; Yonker, Clement R.; Zemanian, Thomas S.; Franz, James A.

    1995-01-01

    The present invention is an arrangement of a glass capillary tube for use in spectroscopy. In particular, the invention is a capillary arranged in a manner permitting a plurality or multiplicity of passes of a sample material through a spectroscopic measurement zone. In a preferred embodiment, the multi-pass capillary is insertable within a standard NMR sample tube. The present invention further includes a method of making the multi-pass capillary tube and an apparatus for spinning the tube.

  16. Users manual for the Chameleon parallel programming tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gropp, W.; Smith, B.

    1993-06-01

    Message passing is a common method for writing programs for distributed-memory parallel computers. Unfortunately, the lack of a standard for message passing has hampered the construction of portable and efficient parallel programs. In an attempt to remedy this problem, a number of groups have developed their own message-passing systems, each with its own strengths and weaknesses. Chameleon is a second-generation system of this type. Rather than replacing these existing systems, Chameleon is meant to supplement them by providing a uniform way to access many of these systems. Chameleon`s goals are to (a) be very lightweight (low over-head), (b) be highlymore » portable, and (c) help standardize program startup and the use of emerging message-passing operations such as collective operations on subsets of processors. Chameleon also provides a way to port programs written using PICL or Intel NX message passing to other systems, including collections of workstations. Chameleon is tracking the Message-Passing Interface (MPI) draft standard and will provide both an MPI implementation and an MPI transport layer. Chameleon provides support for heterogeneous computing by using p4 and PVM. Chameleon`s support for homogeneous computing includes the portable libraries p4, PICL, and PVM and vendor-specific implementation for Intel NX, IBM EUI (SP-1), and Thinking Machines CMMD (CM-5). Support for Ncube and PVM 3.x is also under development.« less

  17. Living in the country and studying in the city. The art of passing exams and remaining sane.

    PubMed

    Grant, Cameron C; Pinnock, Ralph; Asher, M Innes; Sullivan, Michael James

    2008-10-01

    Doctors working in smaller centres have fewer resources available to help them pass the specialist examination components of their training. To describe the delivery of a teaching programme that helps paediatricians in training in both peripheral and regional centres in New Zealand (NZ) to successfully prepare for their specialist written examinations. The teaching programme was initially developed for paediatricians in training in Auckland and then developed into a national teaching resource. Real-time visual and auditory communication among the various teaching sites was established by the NZ Telepaediatric Service. The sessions were also available for subsequent review, initially as a DVD recording or via a Telepaediatric service videoconferencing unit and, since 2007, as a webcast. In association with the development of this teaching programme, the percentage pass rate for the paediatric specialist examinations has increased significantly for those exam candidates that access the teaching sessions remotely from other NZ centres (60% vs. 82%, chi(1)(2) = 4.28, P = 0.04). Between 80 and 90% of NZ candidates now pass the examination. In comparison, the pass rate for Australian candidates sitting the identical examination remains between 60 and 70%. Telepaediatrics has enabled interactive sessions to be conducted with students in peripheral and the other regional centres as well as those attending in person in Auckland. Its development has enabled examination pass rates in smaller centres to increase.

  18. Improved multiple-pass Raman spectrometer

    NASA Astrophysics Data System (ADS)

    Kc, Utsav; Silver, Joel A.; Hovde, David C.; Varghese, Philip L.

    2011-08-01

    An improved Raman gain spectrometer for flame measurements of gas temperature and species concentrations is described. This instrument uses a multiple-pass optical cell to enhance the incident light intensity in the measurement volume. The Raman signal is 83 times larger than from a single pass, and the Raman signal-to-noise ratio (SNR) in room-temperature air of 153 is an improvement over that from a single-pass cell by a factor of 9.3 when the cell is operated with 100 passes and the signal is integrated over 20 laser shots. The SNR improvement with the multipass cell is even higher for flame measurements at atmospheric pressure, because detector readout noise is more significant for single-pass measurements when the gas density is lower. Raman scattering is collected and dispersed in a spectrograph with a transmission grating and recorded with a fast gated CCD array detector to help eliminate flame interferences. The instrument is used to record spontaneous Raman spectra from N2, CO2, O2, and CO in a methane--air flame. Curve fits of the recorded Raman spectra to detailed simulations of nitrogen spectra are used to determine the flame temperature from the shapes of the spectral signatures and from the ratio of the total intensities of the Stokes and anti-Stokes signals. The temperatures measured are in good agreement with radiation-corrected thermocouple measurements for a range of equivalence ratios.

  19. Effect of fit testing on the protection offered by n95 filtering facepiece respirators against fine particles in a laboratory setting.

    PubMed

    Reponen, Tiina; Lee, Shu-An; Grinshpun, Sergey A; Johnson, Erik; McKay, Roy

    2011-04-01

    This study investigated particle-size-selective protection factors (PFs) of four models of N95 filtering facepiece respirators (FFRs) that passed and failed fit testing. Particle size ranges were representative of individual viruses and bacteria (aerodynamic diameter d(a) = 0.04-1.3 μm). Standard respirator fit testing was followed by particle-size-selective measurement of PFs while subjects wore N95 FFRs in a test chamber. PF values obtained for all subjects were then compared to those obtained for the subjects who passed the fit testing. Overall fit test passing rate for all four models of FFRs was 67%. Of these, 29% had PFs <10 (the Occupational Safety and Health Administration Assigned Protection Factor designated for this type of respirator). When only subjects that passed fit testing were included, PFs improved with 9% having values <10. On average, the PFs were 1.4 times (29.5/21.5) higher when only data for those who passed fit testing were included. The minimum PFs were consistently observed in the particle size range of 0.08-0.2 μm. Overall PFs increased when subjects passed fit testing. The results support the value of fit testing but also show for the first time that PFs are dependent on particle size regardless of fit testing status.

  20. [Dyslexia as a disfunction in successive processing].

    PubMed

    Pérez-Alvarez, F; Timoneda-Gallart, C

    We present a study on reading and writing difficulties after normal instruction during a year. Verifying if these patients showed a specific pattern of PASS (Planning, Attention, Sequential and Simultaneous) cognitive processing; if so, it allows us a rapid diagnosis and a useful cognitive remediation according to the PASS theory of intelligence. Thirty patients were selected from neuropediatric patients because of learning disability. They were selected according to their performance on several tests of phonological aware and a test of writing to discover errors in spelling. Patients with verbal language problems, as in dysphasia, and patients with learning difficulty not determined by reading or writing were ruled out. A control group of 300 scholars was used. The translated DN:CAS battery was administered to the study group and the control group for assessing the PASS cognitive processing. Statistical factorial analysis of the control group was performed as a validity confirmation to discriminate the four PASS cognitive processes. Cluster analysis of the study group was performed to discriminate its homogeneity. Differences between means were tested with the t-Student. The four PASS cognitive processes were identified in the control group. The study group scored less than minus 1 SD in successive processing, the rest of the processes being clearly higher than minus 1 SD, and the mean of study group was inferior to control group (p = 0.001). A kind of dyslexia may be defined by disfunction in PASS successive processing.

  1. A Weld Position Recognition Method Based on Directional and Structured Light Information Fusion in Multi-Layer/Multi-Pass Welding.

    PubMed

    Zeng, Jinle; Chang, Baohua; Du, Dong; Wang, Li; Chang, Shuhe; Peng, Guodong; Wang, Wenzhu

    2018-01-05

    Multi-layer/multi-pass welding (MLMPW) technology is widely used in the energy industry to join thick components. During automatic welding using robots or other actuators, it is very important to recognize the actual weld pass position using visual methods, which can then be used not only to perform reasonable path planning for actuators, but also to correct any deviations between the welding torch and the weld pass position in real time. However, due to the small geometrical differences between adjacent weld passes, existing weld position recognition technologies such as structured light methods are not suitable for weld position detection in MLMPW. This paper proposes a novel method for weld position detection, which fuses various kinds of information in MLMPW. First, a synchronous acquisition method is developed to obtain various kinds of visual information when directional light and structured light sources are on, respectively. Then, interferences are eliminated by fusing adjacent images. Finally, the information from directional and structured light images is fused to obtain the 3D positions of the weld passes. Experiment results show that each process can be done in 30 ms and the deviation is less than 0.6 mm. The proposed method can be used for automatic path planning and seam tracking in the robotic MLMPW process as well as electron beam freeform fabrication process.

  2. Influence of multiple-passes on microstructure and mechanical properties of Al-Mg/SiC surface composites fabricated via underwater friction stir processing

    NASA Astrophysics Data System (ADS)

    Srivastava, Manu; Rathee, Sandeep; Maheshwari, Sachin; Siddiquee, Arshad Noor

    2018-06-01

    Friction stir processing (FSP) is a relatively newly developed solid-state process involving surface modifications for fabricating metal matrix surface composites. Obtaining metal matrix nano-composites with uniform dispersion of reinforcement particles via FSP route is an intricate task to accomplish. In this work, AA5059/SiC nano surface composites (SCs) were developed. Effect of multiple FSP passes and SiC addition on microstructure and mechanical properties of fabricated SCs during underwater condition was investigated. Results reflected that the average microhardness value of base metal (BM) increases from 85 Hv to 159 Hv in stir zone of four pass underwater friction stir processed (FSPed) SC. Highest ultimate tensile strength (UTS) achieved during four pass FSPed sample was 377 MPa that is higher than UTS of BM (321 MPa) and four pass FSPed sample developed at ambient air FSP conditions (347 MPa). An appreciably narrower heat affected zone is obtained owing to fast cooling and reduced heat conduction during underwater FSP, amounting to higher UTS as compared to BM and SC at ambient conditions. Thus, it can be concluded that surrounding medium and number of FSP passes have significant impact on mechanical properties of fabricated SCs. Analysis of microstructures and distribution of SiC particles in fabricated SCs were studied by optical microscope and FESEM respectively and found in good corroboration with the mechanical properties.

  3. Double Pass 595 nm Pulsed Dye Laser Does Not Enhance the Efficacy of Port Wine Stains Compared with Single Pass: A Randomized Comparison with Histological Examination.

    PubMed

    Yu, Wenxin; Zhu, Jiafang; Wang, Lizhen; Qiu, Yajing; Chen, Yijie; Yang, Xi; Chang, Lei; Ma, Gang; Lin, Xiaoxi

    2018-03-27

    To compare the efficacy and safety of double-pass pulsed dye laser (DWL) and single-pass PDL (SWL) in treating virgin port wine stain (PWS). The increase in the extent of vascular damage attributed to the use of double-pass techniques for PWS remains inconclusive. A prospective, side-by-side comparison with a histological study for virgin PWS is still lacking. Twenty-one patients (11 flat PWS, 10 hypertrophic PWS) with untreated PWS underwent 3 treatments at 2-month intervals. Each PWS was divided into three treatment sites: SWL, DWL, and untreated control. Chromametric and visual evaluation of the efficacy and evaluation of side effects were conducted 3 months after final treatment. Biopsies were taken at the treated sites immediately posttreatment. Chromametric and visual evaluation suggested that DWL sites showed no significant improvement compared with SWL (p > 0.05) in treating PWS. The mean depth of photothermal damage to the vessels was limited to a maximum of 0.36-0.41 mm in both SWL and DWL sides. Permanent side effects were not observed in any patients. Double-pass PDL does not enhance PWS clearance. To improve the clearance of PWS lesions, either the depth of laser penetration should be increased or greater photothermal damage to vessels should be generated.

  4. Stream capture to form Red Pass, northern Soda Mountains, California

    USGS Publications Warehouse

    Miller, David; Mahan, Shannon

    2014-01-01

    Red Pass, a narrow cut through the Soda Mountains important for prehistoric and early historic travelers, is quite young geologically. Its history of downcutting to capture streams west of the Soda Mountains, thereby draining much of eastern Fort Irwin, is told by the contrast in alluvial fan sediments on either side of the pass. Old alluvial fan deposits (>500 ka) were shed westward off an intact ridge of the Soda Mountains but by middle Pleistocene time, intermediate-age alluvial fan deposits (~100 ka) were laid down by streams flowing east through the pass into Silurian Valley. The pass was probably formed by stream capture driven by high levels of groundwater on the west side. This is evidenced by widespread wetland deposits west of the Soda Mountains. Sapping and spring discharge into Silurian Valley over millennia formed a low divide in the mountains that eventually was overtopped and incised by a stream. Lessons include the importance of groundwater levels for stream capture and the relatively youthful appearance of this ~100-200 ka feature in the slowly changing Mojave Desert landscape.

  5. Physicochemical properties of bio-oil and biochar produced by fast pyrolysis of stored single-pass corn stover and cobs.

    PubMed

    Shah, Ajay; Darr, Matthew J; Dalluge, Dustin; Medic, Dorde; Webster, Keith; Brown, Robert C

    2012-12-01

    Short harvest window of corn (Zea mays) stover necessitates its storage before utilization; however, there is not enough work towards exploring the fast pyrolysis behavior of stored biomass. This study investigated the yields and the physicochemical properties (proximate and ultimate analyses, higher heating values and acidity) of the fast pyrolysis products obtained from single-pass stover and cobs stored either inside a metal building or anaerobically within plastic wraps. Biomass samples were pyrolyzed in a 183 cm long and 2.1cm inner diameter free-fall fast pyrolysis reactor. Yields of bio-oil, biochar and non-condensable gases from different biomass samples were in the ranges of 45-55, 25-37 and 11-17 wt.%, respectively, with the highest bio-oil yield from the ensiled single-pass stover. Bio-oils generated from ensiled single-pass cobs and ensiled single-pass stover were, respectively, the most and the least acidic with the modified acid numbers of 95.0 and 65.2 mg g(-1), respectively. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Performance Comparison of a Matrix Solver on a Heterogeneous Network Using Two Implementations of MPI: MPICH and LAM

    NASA Technical Reports Server (NTRS)

    Phillips, Jennifer K.

    1995-01-01

    Two of the current and most popular implementations of the Message-Passing Standard, Message Passing Interface (MPI), were contrasted: MPICH by Argonne National Laboratory, and LAM by the Ohio Supercomputer Center at Ohio State University. A parallel skyline matrix solver was adapted to be run in a heterogeneous environment using MPI. The Message-Passing Interface Forum was held in May 1994 which lead to a specification of library functions that implement the message-passing model of parallel communication. LAM, which creates it's own environment, is more robust in a highly heterogeneous network. MPICH uses the environment native to the machine architecture. While neither of these free-ware implementations provides the performance of native message-passing or vendor's implementations, MPICH begins to approach that performance on the SP-2. The machines used in this study were: IBM RS6000, 3 Sun4, SGI, and the IBM SP-2. Each machine is unique and a few machines required specific modifications during the installation. When installed correctly, both implementations worked well with only minor problems.

  7. Passivation Behavior of Ultrafine-Grained Pure Copper Fabricated by Accumulative Roll Bonding (ARB) Process

    NASA Astrophysics Data System (ADS)

    Fattah-alhosseini, Arash; Imantalab, Omid

    2016-01-01

    In this study, passivation behavior of ultrafine-grained (UFG) pure copper fabricated by ARB process in 0.01 M borax solution has been investigated. Before any electrochemical measurements, evaluation of microstructure was obtained by transmission electron microscopy (TEM). TEM observations revealed that with increasing the number of ARB passes, the grain size of specimens decrease. Also, TEM images showed that UFGs with average size of below 100 nm appeared after 7 passes of ARB. To investigate the passivation behavior of the specimens, electrochemical impedance spectroscopy (EIS) and Mott-Schottky analysis was carried out. For this purpose, three potentials within the passive region were chosen for potentiostatic passive film growth. EIS results showed that both passive film and charge-transfer resistance increases with increasing the number of ARB passes. Moreover, Mott-Schottky analysis revealed that with increasing the number of ARB passes, the acceptor density of the passive films decreased. In conclusion, increasing the number of ARB passes offers better conditions for forming the passive films with higher protection behavior, due to the growth of a much thicker and less defective films.

  8. Decision-Tree Analysis for Predicting First-Time Pass/Fail Rates for the NCLEX-RN® in Associate Degree Nursing Students.

    PubMed

    Chen, Hsiu-Chin; Bennett, Sean

    2016-08-01

    Little evidence shows the use of decision-tree algorithms in identifying predictors and analyzing their associations with pass rates for the NCLEX-RN(®) in associate degree nursing students. This longitudinal and retrospective cohort study investigated whether a decision-tree algorithm could be used to develop an accurate prediction model for the students' passing or failing the NCLEX-RN. This study used archived data from 453 associate degree nursing students in a selected program. The chi-squared automatic interaction detection analysis of the decision trees module was used to examine the effect of the collected predictors on passing/failing the NCLEX-RN. The actual percentage scores of Assessment Technologies Institute®'s RN Comprehensive Predictor(®) accurately identified students at risk of failing. The classification model correctly classified 92.7% of the students for passing. This study applied the decision-tree model to analyze a sequence database for developing a prediction model for early remediation in preparation for the NCLEXRN. [J Nurs Educ. 2016;55(8):454-457.]. Copyright 2016, SLACK Incorporated.

  9. Double-pass measurement of human eye aberrations: limitations and practical realization

    NASA Astrophysics Data System (ADS)

    Letfullin, Renat R.; Belyakov, Alexey I.; Cherezova, Tatyana Y.; Kudryashov, Alexis V.

    2004-11-01

    The problem of correct eye aberrations measurement is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). The double-pass technique commonly used for measuring aberrations of a human eye involves some uncertainties. One of them is loosing the information about odd human eye aberrations. We report about investigations of the applicability limit of the double-pass measurements depending upon the aberrations status introduced by human eye and actual size of the entrance pupil. We evaluate the double-pass effects for various aberrations and different pupil diameters. It is shown that for small pupils the double-pass effects are negligible. The testing and alignment of aberrometer was performed using the schematic eye, developed in our lab. We also introduced a model of human eye based on bimorph flexible mirror. We perform calculations to demonstrate that our schematic eye is capable of reproducing spatial-temporal statistics of aberrations of living eye with normal vision or even myopic or hypermetropic or with high aberrations ones.

  10. Analysis of the NASA/MSFC Airborne Doppler Lidar results from San Gorgonio Pass, California

    NASA Technical Reports Server (NTRS)

    Cliff, W. C.; Skarda, J. R.; Renne, D. S.; Sandusky, W. F.

    1984-01-01

    Two days during July of 1981 the NASA/MSFC Airborne Doppler Lidar System (ADLS) was flown aboard the NASA/AMES Convair 990 on the east side of San Gorgonio Pass California, near Palm Springs, to measure and investigate the accelerated atmospheric wind field discharging from the pass. The vertical and horizontal extent of the fast moving atmospheric flow discharging from the San Gorgonio Pass were examined. Conventional ground measurements were also taken during the tests to assist in validating the ADLS results. This particular region is recognized as a high wind resource region and, as such, a knowledge of the horizontal and vertical extent of this flow was of interest for wind energy applications. The statistics of the atmospheric flow field itself as it discharges from the pass and then spreads out over the desert were also of scientific interests. This data provided the first spatial data for ensemble averaging of spatial correlations to compute longitudinal and lateral integral length scales in the longitudinal and lateral directions for both components.

  11. Secchi disk observation with spectral-selective glasses in blue and green waters.

    PubMed

    Lee, Zhongping; Shang, Shaoling; Lin, Gong; Liu, Tongtong; Liu, Yangyang; Du, Keping; Luis, Kelly

    2017-08-21

    Radiative transfer modeling of Secchi disk observations has historically been based on conjugated signals of eye response and radiance, where water's attenuation in the entire visible band is included in the attenuation when deciding the Secchi disk depth in water. Aas et al. [Ocean Sci.10(2), 177 (2014)Remote Sens. Environ.169, 139 (2015)] hypothesized that it is actually the attenuation in water's transparent window that matters to the observation of a Secchi disk in water. To test this hypothesis, observations of Secchi disks in blue and green waters were conducted via naked eyes, blue-pass glasses, and green-pass glasses. Measurement results indicate that for blue waters, the observed Secchi depths via naked eyes match the depths obtained with blue-pass glasses and much deeper than the depths with green-pass glasses, although the green-pass glasses match the highest response of human eyes. These observations experimentally support the hypothesis that our eye-brain system uses the contrast information in the transparent window to make a judgement decision regarding sighting a Secchi disk in water.

  12. SEMICONDUCTOR INTEGRATED CIRCUITS: An asymmetric MOSFET-C band-pass filter with on-chip charge pump auto-tuning

    NASA Astrophysics Data System (ADS)

    Fangxiong, Chen; Min, Lin; Heping, Ma; Hailong, Jia; Yin, Shi; Forster, Dai

    2009-08-01

    An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 μm CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 Ω as the source impedance. The input referred noise is about 47.455 μVrms. The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm2 and it can be utilized in GPS (global positioning system) and Bluetooth systems.

  13. Hydrodynamic interaction of two deformable drops in confined shear flow.

    PubMed

    Chen, Yongping; Wang, Chengyao

    2014-09-01

    We investigate hydrodynamic interaction between two neutrally buoyant circular drops in a confined shear flow based on a computational fluid dynamics simulation using the volume-of-fluid method. The rheological behaviors of interactive drops and the flow regimes are explored with a focus on elucidation of underlying physical mechanisms. We find that two types of drop behaviors during interaction occur, including passing-over motion and reversing motion, which are governed by the competition between the drag of passing flow and the entrainment of reversing flow in matrix fluid. With the increasing confinement, the drop behavior transits from the passing-over motion to reversing motion, because the entrainment of the reversing-flow matrix fluid turns to play the dominant role. The drag of the ambient passing flow is increased by enlarging the initial lateral separation due to the departure of the drop from the reversing flow in matrix fluid, resulting in the emergence of passing-over motion. In particular, a corresponding phase diagram is plotted to quantitatively illustrate the dependence of drop morphologies during interaction on confinement and initial lateral separation.

  14. BOREAS AFM-2 King Air 1994 Aircraft Flux and Moving Window Data

    NASA Technical Reports Server (NTRS)

    Kelly, Robert D.; Hall, Forrest G. (Editor); Newcomer, Jeffrey A. (Editor); Smith, David E. (Technical Monitor)

    2000-01-01

    The BOREAS AFM-2 team collected pass-by-pass fluxes (and many other statistics) for a large number of level (constant altitude), straight-line passes used in a variety of flight patterns. The data were collected by the University of Wyoming King Air in 1994 BOREAS IFCs 1-3. Most of these data were collected at 60-70 m above ground level, but a significant number of passes were also flown at various levels in the planetary boundary layer, up to about the inversion height. This documentation concerns only the data from the straight and level passes that are presented as original (over the NSA and SSA) and moving window values (over the Transect). Another archive of King Air data is also available, containing data from all the soundings flown by the King Air 1994 IFCs 1-3. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

  15. Forward light scatter analysis of the eye in a spatially-resolved double-pass optical system.

    PubMed

    Nam, Jayoung; Thibos, Larry N; Bradley, Arthur; Himebaugh, Nikole; Liu, Haixia

    2011-04-11

    An optical analysis is developed to separate forward light scatter of the human eye from the conventional wavefront aberrations in a double pass optical system. To quantify the separate contributions made by these micro- and macro-aberrations, respectively, to the spot image blur in the Shark-Hartmann aberrometer, we develop a metric called radial variance for spot blur. We prove an additivity property for radial variance that allows us to distinguish between spot blurs from macro-aberrations and micro-aberrations. When the method is applied to tear break-up in the human eye, we find that micro-aberrations in the second pass accounts for about 87% of the double pass image blur in the Shack-Hartmann wavefront aberrometer under our experimental conditions. © 2011 Optical Society of America

  16. Aeroassisted orbit transfer vehicle trajectory analysis

    NASA Technical Reports Server (NTRS)

    Braun, Robert D.; Suit, William T.

    1988-01-01

    The emphasis in this study was on the use of multiple pass trajectories for aerobraking. However, for comparison, single pass trajectories, trajectories using ballutes, and trajectories corrupted by atmospheric anomolies were run. A two-pass trajectory was chosen to determine the relation between sensitivity to errors and payload to orbit. Trajectories that used only aerodynamic forces for maneuvering could put more weight into the target orbits but were very sensitive to variations from the planned trajectors. Using some thrust control resulted in less payload to orbit, but greatly reduced the sensitivity to variations from nominal trajectories. When compared to the non-thrusting trajectories investigated, the judicious use of thrusting resulted in multiple pass trajectories that gave 97 percent of the payload to orbit with almost none of the sensitivity to variations from the nominal.

  17. Long Return Periods for Earthquakes in San Gorgonio Pass and Implications for Large Ruptures of the San Andreas Fault in Southern California

    NASA Astrophysics Data System (ADS)

    Yule, J.; McBurnett, P.; Ramzan, S.

    2011-12-01

    The largest discontinuity in the surface trace of the San Andreas fault occurs in southern California at San Gorgonio Pass. Here, San Andreas motion moves through a 20 km-wide compressive stepover on the dextral-oblique-slip thrust system known as the San Gorgonio Pass fault zone. This thrust-dominated system is thought to rupture during very large San Andreas events that also involve strike-slip fault segments north and south of the Pass region. A wealth of paleoseismic data document that the San Andreas fault segments on either side of the Pass, in the San Bernardino/Mojave Desert and Coachella Valley regions, rupture on average every ~100 yrs and ~200 yrs, respectively. In contrast, we report here a notably longer return period for ruptures of the San Gorgonio Pass fault zone. For example, features exposed in trenches at the Cabezon site reveal that the most recent earthquake occurred 600-700 yrs ago (this and other ages reported here are constrained by C-14 calibrated ages from charcoal). The rupture at Cabezon broke a 10 m-wide zone of east-west striking thrusts and produced a >2 m-high scarp. Slip during this event is estimated to be >4.5 m. Evidence for a penultimate event was not uncovered but presumably lies beneath ~1000 yr-old strata at the base of the trenches. In Millard Canyon, 5 km to the west of Cabezon, the San Gorgonio Pass fault zone splits into two splays. The northern splay is expressed by 2.5 ± 0.7 m and 5.0 ± 0.7 m scarps in alluvial terraces constrained to be ~1300 and ~2500 yrs old, respectively. The scarp on the younger, low terrace postdates terrace abandonment ~1300 yrs ago and probably correlates with the 600-700 yr-old event at Cabezon, though we cannot rule out that a different event produced the northern Millard scarp. Trenches excavated in the low terrace reveal growth folding and secondary faulting and clear evidence for a penultimate event ~1350-1450 yrs ago, during alluvial deposition prior to the abandonment of the low terrace. Subtle evidence for a third event is poorly constrained by age data to have occurred between 1600 and 2500 yrs ago. The southern splay at Millard Canyon forms a 1.5 ± 0.1 m scarp in an alluvial terrace that is inset into the lowest terrace at the northern Millard site, and therefore must be < ~1300 yrs old. Slip on this fault probably occurred during the most recent rupture in the Pass. In summary, we think that the most recent earthquake occurred 600-700 yrs ago and generated ~6 m of slip on the San Gorgonio Pass fault zone. The evidence for two older earthquakes is less complete but suggests that they are similar in style and magnitude to the most recent event. The available data therefore suggest that the San Gorgonio Pass fault zone has produced three large (~6 m) events in the last ~2000 yrs, a return period of ~700 yrs assuming that the next rupture is imminent. We prefer a model whereby a majority of San Andreas fault ruptures end as they approach the Pass region from the north or the south (like the Wrightwood event of A.D. 1812 and possibly the Coachella Valley event of ~A.D. 1680). Relatively rare (once-per-millennia?), through-going San Andreas events break the San Gorgonio Pass fault zone and produce the region's largest earthquakes.

  18. Statistics of Epidemics in Networks by Passing Messages

    NASA Astrophysics Data System (ADS)

    Shrestha, Munik Kumar

    Epidemic processes are common out-of-equilibrium phenomena of broad interdisciplinary interest. In this thesis, we show how message-passing approach can be a helpful tool for simulating epidemic models in disordered medium like networks, and in particular for estimating the probability that a given node will become infectious at a particular time. The sort of dynamics we consider are stochastic, where randomness can arise from the stochastic events or from the randomness of network structures. As in belief propagation, variables or messages in message-passing approach are defined on the directed edges of a network. However, unlike belief propagation, where the posterior distributions are updated according to Bayes' rule, in message-passing approach we write differential equations for the messages over time. It takes correlations between neighboring nodes into account while preventing causal signals from backtracking to their immediate source, and thus avoids "echo chamber effects" where a pair of adjacent nodes each amplify the probability that the other is infectious. In our first results, we develop a message-passing approach to threshold models of behavior popular in sociology. These are models, first proposed by Granovetter, where individuals have to hear about a trend or behavior from some number of neighbors before adopting it themselves. In thermodynamic limit of large random networks, we provide an exact analytic scheme while calculating the time dependence of the probabilities and thus learning about the whole dynamics of bootstrap percolation, which is a simple model known in statistical physics for exhibiting discontinuous phase transition. As an application, we apply a similar model to financial networks, studying when bankruptcies spread due to the sudden devaluation of shared assets in overlapping portfolios. We predict that although diversification may be good for individual institutions, it can create dangerous systemic effects, and as a result financial contagion gets worse with too much diversification. We also predict that financial system exhibits "robust yet fragile" behavior, with regions of the parameter space where contagion is rare but catastrophic whenever it occurs. In further results, we develop a message-passing approach to recurrent state epidemics like susceptible-infectious-susceptible and susceptible-infectious-recovered-susceptible where nodes can return to previously inhabited states and multiple waves of infection can pass through the population. Given that message-passing has been applied exclusively to models with one-way state changes like susceptible-infectious and susceptible-infectious-recovered, we develop message-passing for recurrent epidemics based on a new class of differential equations and demonstrate that our approach is simple and efficiently approximates results obtained from Monte Carlo simulation, and that the accuracy of message-passing is often superior to the pair approximation (which also takes second-order correlations into account).

  19. Genetic Discrimination

    MedlinePlus

    ... the News Canadian 41 st Parliament Passes New Law, S-201 "Genetic Non-Discrimination Act" Canadian lawmakers passed ... Title II). Read more Genetic Discrimination and Other Laws Genetic Discrimination and Other Laws includes the Health ...

  20. Channel Shoaling with Deepening of Houma Navigation Channel at Cat Island Pass, Louisiana

    DTIC Science & Technology

    2011-01-01

    is, Ac (m2)=6.992x10-4P0.86 (m3) (2) The minimum cross-sectional area for Cat Island Pass has increased through time, approximately 32,100...Journal of Coastal Research SI 59 256-265 West Palm Beach, Florida 2011 Channel Shoaling with Deepening of Houma Navigation Channel at Cat ...Deepening of Houma Navigation Channel at Cat Island Pass, Louisiana. In: Roberts, T.M., Rosati, J.D., and Wang, P. (eds.), Proceedings, Symposium to Honor

  1. Evaluation of a Constrained Facet Analysis Efficiency Model for Identifying the Efficiency of Medical Treatment Facilities in the Army Medical Department

    DTIC Science & Technology

    1990-07-31

    examples on their use is available with the PASS User Documentation Manual. 2 The data structure of PASS requires a three- lvel organizational...files, and missing control variables. A specific problem noted involved the absence of 8087 mathematical co-processor on the target IBM-XT 21 machine...System, required an operational understanding of the advanced mathematical technique used in the model. Problems with the original release of the PASS

  2. Two-pass smoother based on the SVSF estimation strategy

    NASA Astrophysics Data System (ADS)

    Gadsden, S. A.; Al-Shabi, M.; Kirubarajan, T.

    2015-05-01

    The smooth variable structure filter (SVSF) has seen significant development and research activity in recent years. It is based on sliding mode concepts, which utilizes a switching gain that brings an inherent amount of stability to the estimation process. In this paper, the SVSF is reformulated to present a two-pass smoother based on the SVSF gain. The proposed method is applied on an aerospace flight surface actuator, and the results are compared with the popular Kalman-based two-pass smoother.

  3. Spectrometer capillary vessel and method of making same

    DOEpatents

    Linehan, J.C.; Yonker, C.R.; Zemanian, T.S.; Franz, J.A.

    1995-11-21

    The present invention is an arrangement of a glass capillary tube for use in spectroscopy. In particular, the invention is a capillary arranged in a manner permitting a plurality or multiplicity of passes of a sample material through a spectroscopic measurement zone. In a preferred embodiment, the multi-pass capillary is insertable within a standard NMR sample tube. The present invention further includes a method of making the multi-pass capillary tube and an apparatus for spinning the tube. 13 figs.

  4. Community Project for Accelerator Science and Simulation (ComPASS) Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cary, John R.; Cowan, Benjamin M.; Veitzer, S. A.

    2016-03-04

    Tech-X participated across the full range of ComPASS activities, with efforts in the Energy Frontier primarily through modeling of laser plasma accelerators and dielectric laser acceleration, in the Intensity Frontier primarily through electron cloud modeling, and in Uncertainty Quantification being applied to dielectric laser acceleration. In the following we present the progress and status of our activities for the entire period of the ComPASS project for the different areas of Energy Frontier, Intensity Frontier and Uncertainty Quantification.

  5. Dry method for recycling iodine-loaded silver zeolite

    DOEpatents

    Thomas, Thomas R.; Staples, Bruce A.; Murphy, Llewellyn P.

    1978-05-09

    Fission product iodine is removed from a waste gas stream and stored by passing the gas stream through a bed of silver-exchanged zeolite until the zeolite is loaded with iodine, passing dry hydrogen gas through the bed to remove the iodine and regenerate the bed, and passing the hydrogen stream containing the hydrogen iodide thus formed through a lead-exchanged zeolite which adsorbs the radioactive iodine from the gas stream and permanently storing the lead-exchanged zeolite loaded with radioactive iodine.

  6. Hansen Solubility Parameters for Octahedral Oligomeric Silsesquioxanes

    DTIC Science & Technology

    2012-08-28

    Chujo, Y. Synthesis of organic-inorganic polymer hybrids from poly(vinyl chloride ) and polyhedral oligomeric silsesquioxane via CH/pi interaction...referred to as octa(phenethyl), POSS and either polystyrene22 or polyvinyl chloride .23 However, in many cases, the reported solubility of POSS...Acetonitrile 1.82 Fail E- 1.85 Fail E- 2.40 Fail E- Acetone 0.33 Pass E+ 0.58 Pass E+ 1.27 Pass U+ Allyl Chloride 1.64 Fail E- 1.83 Fail E- 1.42 Fail E

  7. CALUTRON RECEIVERS

    DOEpatents

    Lofgren, E.J.

    1958-09-01

    Improvements are described in isotope separation devices of the calutron type and, in particular, deals with a novel caiutron receiver which passes the optimum portions of the ion beam to a collecting chamber. In broad aspects the receiver provides means for pass delimited pontion of the beam and an elongated collecting pocket disposed to receive ions passed by the beam delimiting means. The collecting pocket is transversely partitioned into a plurality of ion receiving compartments respectively defined by a corresponding plurality of separately removable liner elements.

  8. Degree Distribution of Position-Dependent Ball-Passing Networks in Football Games

    NASA Astrophysics Data System (ADS)

    Narizuka, Takuma; Yamamoto, Ken; Yamazaki, Yoshihiro

    2015-08-01

    We propose a simple stochastic model describing the position-dependent ball-passing network in football (soccer) games. In this network, a player in a certain area in a divided field is a node, and a pass between two nodes corresponds to an edge. Our stochastic process model is characterized by the consecutive choice of a node depending on its intrinsic fitness. We derive an explicit expression for the degree distribution and find that the derived distribution reproduces that for actual data reasonably well.

  9. Space Shuttle Program Primary Avionics Software System (PASS) Success Legacy - Quality and Reliability Date

    NASA Technical Reports Server (NTRS)

    Orr, James K.; Peltier, Daryl

    2010-01-01

    Thsi slide presentation reviews the avionics software system on board the space shuttle, with particular emphasis on the quality and reliability. The Primary Avionics Software System (PASS) provides automatic and fly-by-wire control of critical shuttle systems which executes in redundant computers. Charts given show the number of space shuttle flights vs time, PASS's development history, and other charts that point to the reliability of the system's development. The reliability of the system is also compared to predicted reliability.

  10. Learning Style as a Predictor of First-Time NCLEX-RN Success: Implications for Nurse Educators.

    PubMed

    Lown, Susan G; Hawkins, Lee Ann

    Improving NCLEX-RN® pass rates remains a priority for nursing programs. Many programs collect learning style inventory data, yet few studies have looked at relationships between these data and NCLEX-RN pass/fail rates. Learning style preferences (visual, auditory, tactile, individual, group) and NCLEX pass/fail results were examined for 532 undergraduates in a Midwestern university. A significant correlation between preference for group learning and failure of the NCLEX was found (χ = 5.99, P = .05).

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ploskey, Gene R.; Weiland, Mark A.; Faber, Derrek M.

    This report describes a 2008 acoustic telemetry survival study conducted by the Pacific Northwest National Laboratory for the Portland District of the U.S. Army Corps of Engineers. The study estimated the survival of juvenile Chinook salmon and steelhead passing Bonneville Dam (BON) and its spillway. Of particular interest was the relative survival of smolts detected passing through end spill bays 1-3 and 16-18, which had deep flow deflectors immediately downstream of spill gates, versus survival of smolts passing middle spill bays 4-15, which had shallow flow deflectors.

  12. 60. Adney Gap. View of curvilinear alignment of parkway passing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Adney Gap. View of curvilinear alignment of parkway passing through agricultural lease lands. - Blue Ridge Parkway, Between Shenandoah National Park & Great Smoky Mountains, Asheville, Buncombe County, NC

  13. Publications - GMC 417 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    the Sun Prospect, Ambler Mining District, Survey Pass Quadrangle, Alaska Authors: ALS Minerals Sun Prospect, Ambler Mining District, Survey Pass Quadrangle, Alaska: Alaska Division of Geological

  14. Inward Leakage Variability between Respirator Fit Test Panels – Part I. Deterministic Approach

    PubMed Central

    Zhuang, Ziqing; Liu, Yuewei; Coffey, Christopher C.; Miller, Colleen; Szalajda, Jonathan

    2015-01-01

    Inter-panel variability has never been investigated. The objective of this study was to determine the variability between different anthropometric panels used to determine the inward leakage (IL) of N95 filtering facepiece respirators (FFRs) and elastomeric half-mask respirators (EHRs). A total of 144 subjects, who were both experienced and non-experienced N95 FFR users, were recruited. Five N95 FFRs and five N95 EHRs were randomly selected from among those models tested previously in our laboratory. The PortaCount Pro+ (without N95-Companion) was used to measure IL of the ambient particles with a detectable size range of 0.02 to 1 μm. The Occupational Safety and Health Administration standard fit test exercises were used for this study. IL test were performed for each subject using each of the 10 respirators. Each respirator/subject combination was tested in duplicate, resulting in a total 20 IL tests for each subject. Three 35-member panels were randomly selected without replacement from the 144 study subjects stratified by the National Institute for Occupational Safety and Health bivariate panel cell for conducting statistical analyses. The geometric mean (GM) IL values for all 10 studied respirators were not significantly different among the three randomly selected 35-member panels. Passing rate was not significantly different among the three panels for all respirators combined or by each model. This was true for all IL pass/fail levels of 1%, 2%, and 5%. Using 26 or more subjects to pass the IL test, all three panels had consistent passing/failing results for pass/fail levels of 1% and 5%. Some disagreement was observed for the 2% pass/fail level. Inter-panel variability exists, but it is small relative to the other sources of variation in fit testing data. The concern about inter-panel variability and other types of variability can be alleviated by properly selecting: pass/fail level (IL 1–5%); panel size (e.g., 25 or 35); and minimum number of subjects required to pass (e.g., 26 of 35 or 23 of 35). PMID:26011282

  15. An evaluation of demographic factors affecting performance in a paediatric membership multiple-choice examination.

    PubMed

    Menzies, Lara; Minson, Susan; Brightwell, Alexandra; Davies-Muir, Anna; Long, Andrew; Fertleman, Caroline

    2015-02-01

    To determine if demographic factors are associated with outcome in a multiple-choice, electronically marked paediatric postgraduate examination. Retrospective analysis of pass rates of UK trainees sitting Membership of the Royal College of Paediatrics and Child Health (MRCPCH) part 1B from 2007 to 2011. Data collected by the RCPCH from examination candidates were analysed to assess the effects of gender, age, and country and university of medical qualification on examination outcome. At first attempt at MRCPCH part 1B, the overall pass rate from 2007 to 2011 was 843/2056 (41.0%). In univariate analysis, passing the examination was associated with being a UK graduate (649/1376 (47.2%)) compared with being an international medical graduate (130/520 (25.0%)) (OR 2.68 (95% CI 2.14 to 3.36), p<0.001). There was strong evidence that the proportion of candidates passing the examination differed for graduates of the 19 different UK medical schools (Fisher's exact test p<0.001). In multivariate logistic regression analysis, after adjustment for age, sex and whether the part 1A examination was taken concurrently, being a UK graduate was still strongly associated with passing the examination (OR 3.17 (95% CI 2.41 to 4.17), p<0.001). UK graduates performed best at 26-27 years of age (52.4% pass rate), whereas overseas graduates performed best at ≥38 years of age (50.8% pass rate). MRCPCH part 1B outcome was related to place of primary medical qualification, with a significantly lower pass rate for international medical graduates compared with UK graduates, as well as significant variation in examination outcome between graduates from different UK medical schools. These data may be used to guide new initiatives to improve support and education for these trainees and to inform development of undergraduate curricula and help trainees prepare more successfully for postgraduate examinations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. A Markov chain analysis of the movements of juvenile salmonids in the forebay of McNary Dam, Washington and Oregon, 2006-09

    USGS Publications Warehouse

    Adams, Noah S.; Hatton, Tyson W.

    2012-01-01

    Passage and survival data for yearling and subyearling Chinook salmon and juvenile steelhead were collected at McNary Dam between 2006 and 2009. These data have provided critical information for resource managers to implement structural and operational changes designed to improve the survival of juvenile salmonids as they migrate past the dam. Much of the information collected at McNary Dam was in the form of three-dimensional tracks of fish movements in the forebay. These data depicted the behavior of multiple species (in three dimensions) during different diel periods, spill conditions, powerhouse operations, and test configurations of the surface bypass structures (temporary spillway weirs; TSWs). One of the challenges in reporting three-dimensional results is presenting the information in a manner that allows interested parties to summarize the behavior of many fish over many different conditions across multiple years. To accomplish this, we investigated the feasibility of using a Markov chain analysis to characterize fish movement patterns in the forebay of McNary Dam. The Markov chain analysis is one way that can be used to summarize numerically the behavior of fish in the forebay. Numerically summarizing the behavior of juvenile salmonids in the forebay of McNary Dam using the Markov chain analysis allowed us to confirm what had been previously summarized using visualization software. For example, proportions of yearling and subyearling Chinook salmon passing the three powerhouse areas was often greater in the southern and middle areas, compared to the northern area. The opposite generally was observed for steelhead. Results of this analysis also allowed us to confirm and quantify the extent of milling behavior that had been observed for steelhead. For fish that were first detected in the powerhouse region, less than 0.10 of the steelhead, on average, passed within each of the powerhouse areas. Instead, steelhead transitioned to adjoining areas in the spillway before passing the dam. In comparison, greater than 0.20 of the Chinook salmon passed within the powerhouse areas. Less milling behavior was observed for all species for fish that first approached the spillway. Compared to the powerhouse areas, a higher proportion of fish, regardless of species, passed the spillway areas and fewer transitioned to adjoining areas in the powerhouse. In addition to quantifying what had been previously speculated about the behavior of fish in the forebay of McNary Dam, the Markov chain analysis refined our understanding of how fish behavior and passage can be influenced by changes to the operations and structure of McNary Dam. For example, the addition of TSWs to the spillway area clearly influenced the passage of fish. Previous results have been reported showing that TSWs increased the number of fish passing through non-turbine routes and the fish-track videos indicated, in general, how fish behaved before passing through the TSWs. However, the analysis presented in this report allowed us to better understand how fish moved across the face of the dam before passing the TSWs and provided a way to quantify the effect of TSW location. Installation of the TSWs in bays 22 and 20 clearly increased passage proportions through the southern one-third of the spillway area for all species, most significantly for steelhead. When the TSWs were moved to bays 19 and 20 in 2008, overall passage through the southern one-third of the spillway remained higher than 2006, but decreased from what was observed in 2007. Shifting the TSWs to the north decreased the proportion of fish passing through the TSWs and increased the number of fish that moved to adjoining areas before passing the dam. Perhaps the most interesting new information to come out of the two-step Markov chain analysis relates to how the performance of the TSWs was influenced by their proximity to the powerhouse. During 2007, the highest proportion of fish passing through TSW22 was for fish that transitioned from the powerhouse area. In contrast, a relatively low proportion of fish passed through TSW20 after coming from the powerhouse area. Instead, the proportion of fish that passed TSW20 after coming from the northern part of the spillway was twice as high as the proportion of fish that passed through TSW20 after coming from the powerhouse. During 2008, the TSW in bay 22 was moved to bay 19, leaving the TSW in bay 20 as the one closest to the powerhouse. As was the case when a TSW was located in bay 22; the proportion of fish passing TSW20 after coming from the powerhouse was greater than the proportion of fish passing through TSW20 after coming from the northern part of the spillway. Passage proportions for fish passing through TSW19, the farthest north of the two TSWs during 2008, was higher for fish that came from the northern part of the spillway compared to the proportion of fish that passed through TSW19 after coming from the powerhouse. The Markov chain analysis provided a mathematical way to characterize fish behavior in the forebay of McNary Dam and helped refine our understanding of how fish movements were influenced by operational and structural changes at McNary Dam. The Markov chain analysis also could be used to examine how future structural and operational changes proposed for McNary Dam might influence the passage of juvenile salmonids.

  17. Earth Observation

    NASA Image and Video Library

    2014-09-01

    Earth Observation taken during a night pass by the Expedition 40 crew aboard the International Space Station (ISS). Folder lists this as: New Zealand Aurora night pass. On crewmember's Flickr page - Look straight down into an aurora.

  18. 76 FR 7863 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ... Eligibility of Drugs, Biologicals, and Radiopharmaceutical Agents for Transitional Pass-Through Status Under... physicians can apply for transitional pass-through payment for drugs and biologicals used with services...

  19. Conjunctivitis (Pink Eye) in Newborns

    MedlinePlus

    ... passed from the mother to her baby during childbirth. Even mothers without symptoms (asymptomatic) at the time ... can pass the bacteria to her baby during childbirth. Symptoms of inclusion conjunctivitis include redness of the ...

  20. 33 CFR 110.196 - Sabine Pass Channel, Sabine Pass, Tex.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (a) The anchorage area. The water bounded by a line connecting the following coordinates: Latitude... of their voyages. (2) Except when stress of weather or adverse tides or currents make sailing...

Top