Sample records for passive case detection

  1. Importance of Enhanced Surveillance for Prevention of Pertussis in Children.

    PubMed

    Domínguez, Angela; Godoy, Pere; Toledo, Diana; Soldevila, Núria; García-Cenoz, Manuel; Farrús, Gloria; Crespo, Inma; Caylà, Joan A; Sala, Maria Rosa; Camps, Neus; Barrabeig, Irene; Alvarez, Josep

    2015-07-01

    Bordetella pertussis infection causes considerable morbidity, even in countries with high vaccination coverage. Surveillance of pertussis is usually passive and based on mandatory reporting. We assessed the epidemiologic and clinical characteristics of pertussis cases detected by passive or enhanced surveillance. A prospective population-based study was carried out from January 2012 to December 2013 in Catalonia and Navarre, 2 Spanish regions with a total population of 8.2 million. For each confirmed case, variables of age, sex, clinical symptoms, laboratory results and vaccination status were investigated. Associations between the variables studied and the type of surveillance were assessed by odds ratio (OR) and its 95% confidence interval (CI). Logistic regression was used to estimate adjusted OR (aOR). In children <18 years of age, passive surveillance was the most important source of detection (95.7% in <1 year). In children 5-10 years of age, passive surveillance detected 67.5% of cases. In those ≥18 years, enhanced surveillance was the most frequent source of case detection (82.5%). Inspiratory whoop (aOR: 1.94; 95% CI: 1.40-2.70), apnea (aOR: 1.92; 95% CI: 1.28-2.87) and posttussive vomiting (aOR: 1.43; 95% CI: 1.04-1.96) were symptoms included in the clinical case definition that were associated with passive surveillance. Underreporting of symptomatic cases is important not only in adults, but also in children >1 year of age and suggests that providing clinics with free, fast laboratory diagnostic tests, together with enhanced surveillance of family contacts of any age is necessary to better determine existing cases. Enhanced surveillance may be helpful to better understand transmission patterns in the family and in the community.

  2. Reactive case detection for malaria elimination: real-life experience from an ongoing program in Swaziland.

    PubMed

    Sturrock, Hugh J W; Novotny, Joe M; Kunene, Simon; Dlamini, Sabelo; Zulu, Zulisile; Cohen, Justin M; Hsiang, Michelle S; Greenhouse, Bryan; Gosling, Roly D

    2013-01-01

    As countries move towards malaria elimination, methods to identify infections among populations who do not seek treatment are required. Reactive case detection, whereby individuals living in close proximity to passively detected cases are screened and treated, is one approach being used by a number of countries including Swaziland. An outstanding issue is establishing the epidemiologically and operationally optimal screening radius around each passively detected index case. Using data collected between December 2009 and June 2012 from reactive case detection (RACD) activities in Swaziland, we evaluated the effect of screening radius and other risk factors on the probability of detecting cases by reactive case detection. Using satellite imagery, we also evaluated the household coverage achieved during reactive case detection. Over the study period, 250 cases triggered RACD, which identified a further 74 cases, showing the value of RACD over passive surveillance alone. Results suggest that the odds of detecting a case within the household of the index case were significantly higher than in neighbouring households (odds ratio (OR) 13, 95% CI 3.1-54.4). Furthermore, cases were more likely to be detected when RACD was conducted within a week of the index presenting at a health facility (OR 8.7, 95% CI 1.1-66.4) and if the index household had not been sprayed with insecticide (OR sprayed vs not sprayed 0.11, 95% CI 0.03-0.46). The large number of households missed during RACD indicates that a 1 km screening radius may be impractical in such resource limited settings such as Swaziland. Future RACD in Swaziland could be made more effective by achieving high coverage amongst individuals located near to index cases and in areas where spraying has not been conducted. As well as allowing the programme to implement RACD more rapidly, this would help to more precisely define the optimal screening radius.

  3. Detection of emission sources using passive-remote Fourier transform infrared spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demirgian, J.C.; Macha, S.M.; Darby, S.M.

    1995-12-31

    The detection and identification of toxic chemicals released in the environment is important for public safety. Passive-remote Fourier transform infrared (FTIR) spectrometers can be used to detect these releases. Their primary advantages are their small size and ease of setup and use. Open-path FTIR spectrometers are used to detect concentrations of pollutants from a fixed frame of reference. These instruments detect plumes, but they are too large and difficult to aim to be used to track a plume to its source. Passive remote FTIR spectrometers contain an interferometer, optics, and a detector. They can be used on tripods and inmore » some cases can be hand-held. A telescope can be added to most units. The authors will discuss the capability of passive-remote FTIR spectrometers to detect the origin of plumes. Low concentration plumes were released using a custom-constructed vaporizer. These plumes were detected with different spectrometers from different distances. Passive-remote spectrometers were able to detect small 10 cm on a side chemical releases at concentration-pathlengths at the low parts per million-meter (ppm-m) level.« less

  4. Detection of emission sources using passive-remote Fourier transform infrared spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demirgian, J.C.; Macha, S.M.; Darby, S.M.

    1995-04-01

    The detection and identification of toxic chemicals released in the environment is important for public safety. Passive-remote Fourier transform infrared (FTIR) spectrometers can be used to detect these releases. Their primary advantages are their small size and ease of setup and use. Open-path FTIR spectrometers are used to detect concentrations of pollutants from a fixed frame of reference. These instruments detect plumes, but they are too large and difficult to aim to be used to track a plume to its source. Passive remote FTIR spectrometers contain an interferometer, optics, and a detector. They can be used on tripods and inmore » some cases can be hand-held. A telescope can be added to most units. We will discuss the capability of passive-remote FTIR spectrometers to detect the origin of plumes. Low concentration plumes were released using a custom-constructed vaporizer. These plumes were detected with different spectrometers from different distances. Passive-remote spectrometers were able to detect small 10 cm on a side chemical releases at concentration-pathlengths at the low parts per million-meter (ppm-m) level.« less

  5. Combining Radiography and Passive Measurements for Radiological Threat Detection in Cargo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Erin A.; White, Timothy A.; Jarman, Kenneth D.

    Abstract Radiography is widely understood to provide information complimentary to passive detection: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions which may mask a passive radiological signal. We present a method for combining radiographic and passive data which uses the radiograph to provide an estimate of scatter and attenuation for possible sources. This approach allows quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present first results for this method for a simple modeled test case of a cargo container drivingmore » through a PVT portal. With this inversion approach, we address criteria for an integrated passive and radiographic screening system and how detection of SNM threats might be improved in such a system.« less

  6. An islanding detection methodology combining decision trees and Sandia frequency shift for inverter-based distributed generations

    DOE PAGES

    Azim, Riyasat; Li, Fangxing; Xue, Yaosuo; ...

    2017-07-14

    Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only whenmore » the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.« less

  7. An islanding detection methodology combining decision trees and Sandia frequency shift for inverter-based distributed generations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Azim, Riyasat; Li, Fangxing; Xue, Yaosuo

    Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only whenmore » the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.« less

  8. Testing the Feasibility of a Passive and Active Case Ascertainment System for Multiple Rare Conditions Simultaneously: The Experience in Three US States

    PubMed Central

    McDermott, Suzanne; Ruttenber, Margaret; Mann, Joshua; Smith, Michael G; Royer, Julie; Valdez, Rodolfo

    2016-01-01

    Background Owing to their low prevalence, single rare conditions are difficult to monitor through current state passive and active case ascertainment systems. However, such monitoring is important because, as a group, rare conditions have great impact on the health of affected individuals and the well-being of their caregivers. A viable approach could be to conduct passive and active case ascertainment of several rare conditions simultaneously. This is a report about the feasibility of such an approach. Objective To test the feasibility of a case ascertainment system with passive and active components aimed at monitoring 3 rare conditions simultaneously in 3 states of the United States (Colorado, Kansas, and South Carolina). The 3 conditions are spina bifida, muscular dystrophy, and fragile X syndrome. Methods Teams from each state evaluated the possibility of using current or modified versions of their local passive and active case ascertainment systems and datasets to monitor the 3 conditions. Together, these teams established the case definitions and selected the variables and the abstraction tools for the active case ascertainment approach. After testing the ability of their local passive and active case ascertainment system to capture all 3 conditions, the next steps were to report the number of cases detected actively and passively for each condition, to list the local barriers against the combined passive and active case ascertainment system, and to describe the experiences in trying to overcome these barriers. Results During the test period, the team from South Carolina was able to collect data on all 3 conditions simultaneously for all ages. The Colorado team was also able to collect data on all 3 conditions but, because of age restrictions in its passive and active case ascertainment system, it was able to report few cases of fragile X syndrome. The team from Kansas was able to collect data only on spina bifida. For all states, the implementation of an active component of the ascertainment system was problematic. The passive component appears viable with minor modifications. Conclusions Despite evident barriers, the joint passive and active case ascertainment of rare disorders using modified existing surveillance systems and datasets seems feasible, especially for systems that rely on passive case ascertainment. PMID:27574026

  9. Evaluation of an image-based tracking workflow using a passive marker and resonant micro-coil fiducials for automatic image plane alignment in interventional MRI.

    PubMed

    Neumann, M; Breton, E; Cuvillon, L; Pan, L; Lorenz, C H; de Mathelin, M

    2012-01-01

    In this paper, an original workflow is presented for MR image plane alignment based on tracking in real-time MR images. A test device consisting of two resonant micro-coils and a passive marker is proposed for detection using image-based algorithms. Micro-coils allow for automated initialization of the object detection in dedicated low flip angle projection images; then the passive marker is tracked in clinical real-time MR images, with alternation between two oblique orthogonal image planes along the test device axis; in case the passive marker is lost in real-time images, the workflow is reinitialized. The proposed workflow was designed to minimize dedicated acquisition time to a single dedicated acquisition in the ideal case (no reinitialization required). First experiments have shown promising results for test-device tracking precision, with a mean position error of 0.79 mm and a mean orientation error of 0.24°.

  10. Detecting Ebola with limited laboratory access in the Democratic Republic of Congo: evaluation of a clinical passive surveillance reporting system.

    PubMed

    Ashbaugh, Hayley R; Kuang, Brandon; Gadoth, Adva; Alfonso, Vivian H; Mukadi, Patrick; Doshi, Reena H; Hoff, Nicole A; Sinai, Cyrus; Mossoko, Mathias; Kebela, Benoit Ilunga; Muyembe, Jean-Jacques; Wemakoy, Emile Okitolonda; Rimoin, Anne W

    2017-09-01

    Ebola virus disease (EVD) can be clinically severe and highly fatal, making surveillance efforts for early disease detection of paramount importance. In areas with limited access to laboratory testing, the Integrated Disease Surveillance and Response (IDSR) strategy in the Democratic Republic of Congo (DRC) may be a vital tool in improving outbreak response. Using DRC IDSR data from the nation's four EVD outbreak periods from 2007-2014, we assessed trends of Viral Hemorrhagic Fever (VHF) and EVD differential diagnoses reportable through IDSR. With official case counts from active surveillance of EVD outbreaks, we assessed accuracy of reporting through the IDSR passive surveillance system. Although the active and passive surveillance represent distinct sets of data, the two were correlated, suggesting that passive surveillance based only on clinical evaluation may be a useful predictor of true cases prior to laboratory confirmation. There were 438 suspect VHF cases reported through the IDSR system and 416 EVD cases officially recorded across the outbreaks examined. Although collected prior to official active surveillance cases, case reporting through the IDSR during the 2007, 2008 and 2012 outbreaks coincided with official EVD epidemic curves. Additionally, all outbreak areas experienced increases in suspected cases for both malaria and typhoid fever during EVD outbreaks, underscoring the importance of training health care workers in recognising EVD differential diagnoses and the potential for co-morbidities. © 2017 John Wiley & Sons Ltd.

  11. Fast contactless vibrating structure characterization using real time field programmable gate array-based digital signal processing: demonstrations with a passive wireless acoustic delay line probe and vision.

    PubMed

    Goavec-Mérou, G; Chrétien, N; Friedt, J-M; Sandoz, P; Martin, G; Lenczner, M; Ballandras, S

    2014-01-01

    Vibrating mechanical structure characterization is demonstrated using contactless techniques best suited for mobile and rotating equipments. Fast measurement rates are achieved using Field Programmable Gate Array (FPGA) devices as real-time digital signal processors. Two kinds of algorithms are implemented on FPGA and experimentally validated in the case of the vibrating tuning fork. A first application concerns in-plane displacement detection by vision with sampling rates above 10 kHz, thus reaching frequency ranges above the audio range. A second demonstration concerns pulsed-RADAR cooperative target phase detection and is applied to radiofrequency acoustic transducers used as passive wireless strain gauges. In this case, the 250 ksamples/s refresh rate achieved is only limited by the acoustic sensor design but not by the detection bandwidth. These realizations illustrate the efficiency, interest, and potentialities of FPGA-based real-time digital signal processing for the contactless interrogation of passive embedded probes with high refresh rates.

  12. [Schistosomiasis monitoring and its cost in population in Danyang City, 2010-2014].

    PubMed

    Zhu, Tao; Jiang, Tao; Shi, Yu-kun; Wang, Juan

    2015-12-01

    To explore the monitoring method of the infection source of schistosomiasis in the population of the schistosomiasis transmission-interrupted area with Oncomelania hupensis snails. The changes of schistosomiasis among the population were investigated by using the active and passive monitoring methods in Danyang City from 2010 to 2014, and the cost-effectiveness of the two monitoring methods was evaluated. Totally 49,277 persons were detected for schistosomiasis by dipstick dye immunoassay (DDIA) from 2010 to 2014 and 608 cases were positive, and the positive rate was 1.23%. There were no positive persons by etiology detections. The positive rates of active and passive monitoring methods were 1.61% and 1.13%, respectively and there was a significant difference between them (χ² = 15.982, P < 0.05). The average cost per positive case of the active monitoring was higher than that of the passive monitoring without considering the costs of the mobilization and labor. In the schistosomiasis transmission-interrupted area with snails, the active and passive monitoring methods need to be combined in the future.

  13. An automated cross-correlation based event detection technique and its application to surface passive data set

    USGS Publications Warehouse

    Forghani-Arani, Farnoush; Behura, Jyoti; Haines, Seth S.; Batzle, Mike

    2013-01-01

    In studies on heavy oil, shale reservoirs, tight gas and enhanced geothermal systems, the use of surface passive seismic data to monitor induced microseismicity due to the fluid flow in the subsurface is becoming more common. However, in most studies passive seismic records contain days and months of data and manually analysing the data can be expensive and inaccurate. Moreover, in the presence of noise, detecting the arrival of weak microseismic events becomes challenging. Hence, the use of an automated, accurate and computationally fast technique for event detection in passive seismic data is essential. The conventional automatic event identification algorithm computes a running-window energy ratio of the short-term average to the long-term average of the passive seismic data for each trace. We show that for the common case of a low signal-to-noise ratio in surface passive records, the conventional method is not sufficiently effective at event identification. Here, we extend the conventional algorithm by introducing a technique that is based on the cross-correlation of the energy ratios computed by the conventional method. With our technique we can measure the similarities amongst the computed energy ratios at different traces. Our approach is successful at improving the detectability of events with a low signal-to-noise ratio that are not detectable with the conventional algorithm. Also, our algorithm has the advantage to identify if an event is common to all stations (a regional event) or to a limited number of stations (a local event). We provide examples of applying our technique to synthetic data and a field surface passive data set recorded at a geothermal site.

  14. Surveillance for Chikungunya and Dengue During the First Year of Chikungunya Virus Circulation in Puerto Rico

    PubMed Central

    Sharp, Tyler M.; Ryff, Kyle R.; Alvarado, Luisa; Shieh, Wun-Ju; Zaki, Sherif R.; Margolis, Harold S.; Rivera-Garcia, Brenda

    2016-01-01

    After chikungunya virus (CHIKV) transmission was detected in Puerto Rico in May 2014, multiple surveillance systems were used to describe epidemiologic trends and CHIKV-associated disease. Of 28 327 cases reported via passive surveillance, 6472 were tested for evidence of CHIKV infection, and results for 4399 (68%) were positive. Of 250 participants in household cluster investigations, 70 (28%) had evidence of recent CHIKV infection. Enhanced surveillance for chikungunya at 2 hospitals identified 1566 patients who tested positive for CHIKV, of whom 10.9% were hospitalized. Enhanced surveillance for fatal cases enabled identification of 31 cases in which CHIKV was detected in blood or tissue specimens. All surveillance systems detected a peak incidence of chikungunya in September 2014 and continued circulation in 2015. Concomitant surveillance for dengue demonstrated low incidence, which had decreased before CHIKV was introduced. Multifaceted chikungunya surveillance in Puerto Rico resolved gaps in traditional passive surveillance and enabled a holistic description of the spectrum of disease associated with CHIKV infection. PMID:27920177

  15. Autoantibody-mediated bowel and bladder dysfunction in a patient with chronic, nondiabetic neuropathy.

    PubMed

    Jackson, Michael W; Gordon, Thomas P; McCombe, Pamela A

    2008-04-01

    Physiological techniques can be used to detect novel autoantibodies causing alteration of autonomic function after passive transfer to mice. Previously, such antibodies have been detected in patients with type I diabetes mellitus, myasthenia gravis, and Sjogren's syndrome. We now describe a patient with an idiopathic nondiabetic neuropathy with prominent autonomic symptoms, including bladder and bowel dysfunction. Physiological assays of whole colon and bladder were used to determine the presence in the patient serum of functional autoantibodies capable of mediating autonomic dysfunction. Immunoglobulin G (IgG) from this patient was able to disrupt bladder and bowel function on passive transfer to mice. This is a new pattern of autoantibody-mediated abnormality. Although the target antigen is unknown, it is likely to be a cell-surface receptor or ion channel. This case highlights the usefulness of passive transfer studies in detecting functional antibodies in patients with autonomic neuropathy.

  16. Aggressive active case detection: a malaria control strategy based on the Brazilian model.

    PubMed

    Macauley, Cameron

    2005-02-01

    Since 1996, the Brazilian Ministry of Health has adopted a malaria control strategy known as aggressive active case detection (AACD) in which most or all members of every community are tested and treated for malaria on a monthly basis. The strategy attempts to identify and treat cases of asymptomatic malaria, which, if untreated, continue to transmit the infection. Malaria remains uncontrolled because almost all health care systems in the world rely on passive case detection: the treatment of only symptomatic cases of malaria. Research has shown conclusively that asymptomatic cases exist in any population where malaria transmission is stable and incidence is high: therefore passive case detection simply will not succeed in breaking the cycle of transmission. Numerous case studies show that malaria has been successfully controlled on a regional or national level by mass blood surveys. AACD is an effective malaria control strategy if used in conjunction with other methods, especially when (1) an effective treatment exists, (2) influx of potential carriers of the infection can be monitored, and (3) people are inclined to cooperate with monthly blood testing. AACD requires access to rapid diagnostic tests (RDTs), microscopy supplies, extensive human resources, and prompt, affordable, and effective treatment. AACD is compared to PCD in terms of clinical efficacy and cost effectiveness in a case study of malaria in the Brazilian Yanomami Indians. Where it is feasible, AACD could drastically reduce the incidence of malaria and should be an integral part of the World Health Organization's Roll Back Malaria strategy.

  17. Expanded opportunities of THz passive camera for the detection of concealed objects

    NASA Astrophysics Data System (ADS)

    Trofimov, Vyacheslav A.; Trofimov, Vladislav V.; Kuchik, Igor E.

    2013-10-01

    Among the security problems, the detection of object implanted into either the human body or animal body is the urgent problem. At the present time the main tool for the detection of such object is X-raying only. However, X-ray is the ionized radiation and therefore can not be used often. Other way for the problem solving is passive THz imaging using. In our opinion, using of the passive THz camera may help to detect the object implanted into the human body under certain conditions. The physical reason of such possibility arises from temperature trace on the human skin as a result of the difference in temperature between object and parts of human body. Modern passive THz cameras have not enough resolution in temperature to see this difference. That is why, we use computer processing to enhance the passive THz camera resolution for this application. After computer processing of images captured by passive THz camera TS4, developed by ThruVision Systems Ltd., we may see the pronounced temperature trace on the human body skin from the water, which is drunk by person, or other food eaten by person. Nevertheless, there are many difficulties on the way of full soution of this problem. We illustrate also an improvement of quality of the image captured by comercially available passive THz cameras using computer processing. In some cases, one can fully supress a noise on the image without loss of its quality. Using computer processing of the THz image of objects concealed on the human body, one may improve it many times. Consequently, the instrumental resolution of such device may be increased without any additional engineering efforts.

  18. Effectiveness and Cost Efficiency of Different Surveillance Components for Proving Freedom and Early Detection of Disease: Bluetongue Serotype 8 in Cattle as Case Study for Belgium, France and the Netherlands.

    PubMed

    Welby, S; van Schaik, G; Veldhuis, A; Brouwer-Middelesch, H; Peroz, C; Santman-Berends, I M; Fourichon, C; Wever, P; Van der Stede, Y

    2017-12-01

    Quick detection and recovery of country's freedom status remain a constant challenge in animal health surveillance. The efficacy and cost efficiency of different surveillance components in proving the absence of infection or (early) detection of bluetongue serotype 8 in cattle populations within different countries (the Netherlands, France, Belgium) using surveillance data from years 2006 and 2007 were investigated using an adapted scenario tree model approach. First, surveillance components (sentinel, yearly cross-sectional and passive clinical reporting) within each country were evaluated in terms of efficacy for substantiating freedom of infection. Yearly cross-sectional survey and passive clinical reporting performed well within each country with sensitivity of detection values ranging around 0.99. The sentinel component had a sensitivity of detection around 0.7. Secondly, how effective the components were for (early) detection of bluetongue serotype 8 and whether syndromic surveillance on reproductive performance, milk production and mortality data available from the Netherlands and Belgium could be of added value were evaluated. Epidemic curves were used to estimate the timeliness of detection. Sensitivity analysis revealed that expected within-herd prevalence and number of herds processed were the most influential parameters for proving freedom and early detection. Looking at the assumed direct costs, although total costs were low for sentinel and passive clinical surveillance components, passive clinical surveillance together with syndromic surveillance (based on reproductive performance data) turned out most cost-efficient for the detection of bluetongue serotype 8. To conclude, for emerging or re-emerging vectorborne disease that behaves such as bluetongue serotype 8, it is recommended to use passive clinical and syndromic surveillance as early detection systems for maximum cost efficiency and sensitivity. Once an infection is detected and eradicated, cross-sectional screening for substantiating freedom of infection and sentinel for monitoring the disease evolution are recommended. © 2016 Blackwell Verlag GmbH.

  19. Application of passive imaging polarimetry in the discrimination and detection of different color targets of identical shapes using color-blind imaging sensors

    NASA Astrophysics Data System (ADS)

    El-Saba, A. M.; Alam, M. S.; Surpanani, A.

    2006-05-01

    Important aspects of automatic pattern recognition systems are their ability to efficiently discriminate and detect proper targets with low false alarms. In this paper we extend the applications of passive imaging polarimetry to effectively discriminate and detect different color targets of identical shapes using color-blind imaging sensor. For this case of study we demonstrate that traditional color-blind polarization-insensitive imaging sensors that rely only on the spatial distribution of targets suffer from high false detection rates, especially in scenarios where multiple identical shape targets are present. On the other hand we show that color-blind polarization-sensitive imaging sensors can successfully and efficiently discriminate and detect true targets based on their color only. We highlight the main advantages of using our proposed polarization-encoded imaging sensor.

  20. Parvovirus B19 Passive Transmission by Transfusion of Intercept® Blood System-Treated Platelet Concentrate

    PubMed Central

    Gowland, Peter; Fontana, Stefano; Stolz, Martin; Andina, Nicola; Niederhauser, Christoph

    2016-01-01

    Summary Background Pathogen reduction methods for blood components are effective for a large number of viruses though less against small, non-enveloped viruses such as Parvovirus B19 (B19V). This article describes the passive transmission by transfusion of two B19V-contaminated pooled platelet concentrates (PCs) which were treated with the Intercept® blood pathogen reduction system. Case Reports Two transfusion cases of B19V-contaminated Intercept-treated pooled PCs were described. Due to the analysis delay, the PCs were already transfused. The viral content of each donation was 4.87 × 1010 IU/ml in case 1and 1.46 × 108 IU/ml in case 2. B19V (52 IU/ml) was detected in the recipient of the case 1 PC, whereas no virus could be detected in the case 2 PC recipient. A B19V IgM response and a transient boost of the underlying B19V IgG immune status and was observed in recipient 1. Recipient of the case 2 PC remained B19V IgG- and IgM-negative. B19V DNA sequence and phylogenetic analysis revealed a 100% homology between donor and recipient. Conclusion This report describes passive B19V transmission by a PC with very high B19 viral load which elicited a transient boost of the B19V immunity, but not by a PC with a lower B19V content, suggesting that there is a B19 viral load threshold value at which B19V inactivation is exceeded. PMID:27403092

  1. Discreet passive explosive detection through 2-sided waveguided fluorescence

    DOEpatents

    Harper, Ross James [Stillwater, OK; la Grone, Marcus [Cushing, OK; Fisher, Mark [Stillwater, OK

    2011-10-18

    The current invention provides a passive sampling device suitable for collecting and detecting the presence of target analytes. In particular, the passive sampling device is suitable for detecting nitro-aromatic compounds. The current invention further provides a passive sampling device reader suitable for determining the collection of target analytes. Additionally, the current invention provides methods for detecting target analytes using the passive sampling device and the passive sampling device reader.

  2. Passive smoking and risk of pulmonary tuberculosis in children immediately following infection. A case-control study.

    PubMed

    Altet, M N; Alcaide, J; Plans, P; Taberner, J L; Saltó, E; Folguera, L I; Salleras, L

    1996-12-01

    Passive smoking-related respiratory disorders in children. To assess the effect of passive smoking on the development of active pulmonary tuberculosis (PTB) in children immediately following infection by Mycobacterium tuberculosis within the family. An unmatched case-control study in which 93 contacts who became cases (active PTB diagnosed) and 95 contacts who did not became cases (tuberculin-positive children without evidence of active disease) were included. All were household contacts of a new case of pulmonary bacillary tuberculosis. Smoking habits were investigated by a questionnaire. Urinary cotinine was analysed. Odds Ratio (OR) was adjusted for age and socio-economic status using multiple logistic regression analysis. Passive smoking was a risk factor for PTB (OR: 5.29; 95% confidence interval (CI): 2.33-12.82; P < 0.00005). The adjusted OR was 5.39 (95% CI: 2.44-11.91; P < 0.00001). The risk increased when contacts were passive smokers both at home and outside the home within the family (OR: 6.35; 95% CI: 3.20, 12.72; P < 0.00001). Contacts 0-4 and 5-9 years old showed a significantly higher risk than those aged > or = 10. There was a dose-response relationship between the risk of developing active PTB immediately following infection and the number of cigarettes smoked daily by the household adults (P < 0.001). Mean (SD) urinary continine detectable concentrations (ng/ml) were different between disease contacts (119.46 [68.61]) and non diseased contacts (91.87 [73.10]). The difference was statistically significant (P < 0.001). Passive exposure to tobacco smoke in children was associated with an increased risk of developing pulmonary tuberculosis immediately following infection. This is an association of great concern requiring health education programmes and antitobacco medical advice.

  3. Detection Thresholds of Falling Snow from Satellite-Borne Active and Passive Sensors

    NASA Technical Reports Server (NTRS)

    Jackson, Gail

    2012-01-01

    Precipitation, including rain and snow, is a critical part of the Earth's energy and hydrology cycles. In order to collect information on the complete global precipitation cycle and to understand the energy budget in terms of precipitation, uniform global estimates of both liquid and frozen precipitation must be collected. Active observations of falling snow are somewhat easier to estimate since the radar will detect the precipitation particles and one only needs to know surface temperature to determine if it is liquid rain or snow. The challenges of estimating falling snow from passive spaceborne observations still exist though progress is being made. While these challenges are still being addressed, knowledge of their impact on expected retrieval results is an important key for understanding falling snow retrieval estimations. Important information to assess falling snow retrievals includes knowing thresholds of detection for active and passive sensors, various sensor channel configurations, snow event system characteristics, snowflake particle assumptions, and surface types. For example, can a lake effect snow system with low (2.5 km) cloud tops having an ice water content (Iwe) at the surface of 0.25 g m-3 and dendrite snowflakes be detected? If this information is known, we can focus retrieval efforts on detectable storms and concentrate advances on achievable results. Here, the focus is to determine thresholds of detection for falling snow for various snow conditions over land and lake surfaces. The analysis relies on simulated Weather Research Forecasting (WRF) simulations of falling snow cases since simulations provide all the information to determine the measurements from space and the ground truth. Results are presented for active radar at Ku, Ka, and W-band and for passive radiometer channels from 10 to 183 GHz (Skofronick-Jackson, et al. submitted to IEEE TGRS, April 2012). The notable results show: (1) the W-Band radar has detection thresholds more than an order of magnitude lower than the future GPM sensors, (2) the cloud structure macrophysics influences the thresholds of detection for passive channels, (3) the snowflake microphysics plays a large role in the detection threshold for active and passive instruments, (4) with reasonable assumptions, the passive 166 GHz channel has detection threshold values comparable to the GPM DPR Ku and Ka band radars with 0.05 g m-3 detected at the surface, or an 0.5-1 mm hr-l melted snow rate (equivalent to 0.5-2 cm hr-l solid fluffy snowflake rate).

  4. Discreet passive explosive detection through 2-sided wave guided fluorescence

    DOEpatents

    Harper, Ross James; la Grone, Marcus; Fisher, Mark

    2012-10-16

    The current invention provides a passive sampling device suitable for collecting and detecting the presence of target analytes. In particular, the passive sampling device is suitable for detecting nitro-aromatic compounds. The current invention further provides a passive sampling device reader suitable for determining the collection of target analytes. Additionally, the current invention provides methods for detecting target analytes using the passive sampling device and the passive sampling device reader.

  5. Passive and Active Detection of Clouds: Comparisons between MODIS and GLAS Observations

    NASA Technical Reports Server (NTRS)

    Mahesh, Ashwin; Gray, Mark A.; Palm, Stephen P.; Hart, William D.; Spinhirne, James D.

    2003-01-01

    The Geoscience Laser Altimeter System (GLAS), launched on board the Ice, Cloud and Land Elevation Satellite in January 2003 provides space-borne laser observations of atmospheric layers. GLAS provides opportunities to validate passive observations of the atmosphere for the first time from space with an active optical instrument. Data from the Moderate Resolution Imaging Spectrometer aboard the Aqua satellite is examined along with GLAS observations of cloud layers. In more than three-quarters of the cases, MODIS scene identification from spectral radiances agrees with GLAS. Disagreement between the two platforms is most significant over snow-covered surfaces in the northern hemisphere. Daytime clouds detected by GLAS are also more easily seen in the MODIS data as well, compared to observations made at night. These comparisons illustrate the capabilities of active remote sensing to validate and assess passive measurements, and also to complement them in studies of atmospheric layers.

  6. Surveillance for Chikungunya and Dengue During the First Year of Chikungunya Virus Circulation in Puerto Rico.

    PubMed

    Sharp, Tyler M; Ryff, Kyle R; Alvarado, Luisa; Shieh, Wun-Ju; Zaki, Sherif R; Margolis, Harold S; Rivera-Garcia, Brenda

    2016-12-15

    After chikungunya virus (CHIKV) transmission was detected in Puerto Rico in May 2014, multiple surveillance systems were used to describe epidemiologic trends and CHIKV-associated disease. Of 28 327 cases reported via passive surveillance, 6472 were tested for evidence of CHIKV infection, and results for 4399 (68%) were positive. Of 250 participants in household cluster investigations, 70 (28%) had evidence of recent CHIKV infection. Enhanced surveillance for chikungunya at 2 hospitals identified 1566 patients who tested positive for CHIKV, of whom 10.9% were hospitalized. Enhanced surveillance for fatal cases enabled identification of 31 cases in which CHIKV was detected in blood or tissue specimens. All surveillance systems detected a peak incidence of chikungunya in September 2014 and continued circulation in 2015. Concomitant surveillance for dengue demonstrated low incidence, which had decreased before CHIKV was introduced. Multifaceted chikungunya surveillance in Puerto Rico resolved gaps in traditional passive surveillance and enabled a holistic description of the spectrum of disease associated with CHIKV infection. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  7. Over/Undervoltage and undervoltage shift of hybrid islanding detection method of distributed generation.

    PubMed

    Yingram, Manop; Premrudeepreechacharn, Suttichai

    2015-01-01

    The mainly used local islanding detection methods may be classified as active and passive methods. Passive methods do not perturb the system but they have larger nondetection zones, whereas active methods have smaller nondetection zones but they perturb the system. In this paper, a new hybrid method is proposed to solve this problem. An over/undervoltage (passive method) has been used to initiate an undervoltage shift (active method), which changes the undervoltage shift of inverter, when the passive method cannot have a clear discrimination between islanding and other events in the system. Simulation results on MATLAB/SIMULINK show that over/undervoltage and undervoltage shifts of hybrid islanding detection method are very effective because they can determine anti-islanding condition very fast. ΔP/P > 38.41% could determine anti-islanding condition within 0.04 s; ΔP/P < -24.39% could determine anti-islanding condition within 0.04 s; -24.39% ≤ ΔP/P ≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of -24.39% ≤ ΔP/P ≤ 38.41% at which the control system of inverter injected a signal of undervoltage shift as necessary to check if the occurrence condition was an islanding condition or not.

  8. H7N9 Highly Pathogenic Avian Influenza in the United States in 2017

    USDA-ARS?s Scientific Manuscript database

    In early March of 2017 an outbreak of highly pathogenic avian influenza H7N9 was reported from a broiler-breeder flock Tennessee. A second HPAI case was detected 2 weeks later. Subsequent active and passive surveillance identified several LPAI cases in Alabama, Georgia, Kentucky, and TN that was g...

  9. Analysis on Target Detection and Classification in LTE Based Passive Forward Scattering Radar.

    PubMed

    Raja Abdullah, Raja Syamsul Azmir; Abdul Aziz, Noor Hafizah; Abdul Rashid, Nur Emileen; Ahmad Salah, Asem; Hashim, Fazirulhisyam

    2016-09-29

    The passive bistatic radar (PBR) system can utilize the illuminator of opportunity to enhance radar capability. By utilizing the forward scattering technique and procedure into the specific mode of PBR can provide an improvement in target detection and classification. The system is known as passive Forward Scattering Radar (FSR). The passive FSR system can exploit the peculiar advantage of the enhancement in forward scatter radar cross section (FSRCS) for target detection. Thus, the aim of this paper is to show the feasibility of passive FSR for moving target detection and classification by experimental analysis and results. The signal source is coming from the latest technology of 4G Long-Term Evolution (LTE) base station. A detailed explanation on the passive FSR receiver circuit, the detection scheme and the classification algorithm are given. In addition, the proposed passive FSR circuit employs the self-mixing technique at the receiver; hence the synchronization signal from the transmitter is not required. The experimental results confirm the passive FSR system's capability for ground target detection and classification. Furthermore, this paper illustrates the first classification result in the passive FSR system. The great potential in the passive FSR system provides a new research area in passive radar that can be used for diverse remote monitoring applications.

  10. Analysis on Target Detection and Classification in LTE Based Passive Forward Scattering Radar

    PubMed Central

    Raja Abdullah, Raja Syamsul Azmir; Abdul Aziz, Noor Hafizah; Abdul Rashid, Nur Emileen; Ahmad Salah, Asem; Hashim, Fazirulhisyam

    2016-01-01

    The passive bistatic radar (PBR) system can utilize the illuminator of opportunity to enhance radar capability. By utilizing the forward scattering technique and procedure into the specific mode of PBR can provide an improvement in target detection and classification. The system is known as passive Forward Scattering Radar (FSR). The passive FSR system can exploit the peculiar advantage of the enhancement in forward scatter radar cross section (FSRCS) for target detection. Thus, the aim of this paper is to show the feasibility of passive FSR for moving target detection and classification by experimental analysis and results. The signal source is coming from the latest technology of 4G Long-Term Evolution (LTE) base station. A detailed explanation on the passive FSR receiver circuit, the detection scheme and the classification algorithm are given. In addition, the proposed passive FSR circuit employs the self-mixing technique at the receiver; hence the synchronization signal from the transmitter is not required. The experimental results confirm the passive FSR system’s capability for ground target detection and classification. Furthermore, this paper illustrates the first classification result in the passive FSR system. The great potential in the passive FSR system provides a new research area in passive radar that can be used for diverse remote monitoring applications. PMID:27690051

  11. Global Passivity in Microscopic Thermodynamics

    NASA Astrophysics Data System (ADS)

    Uzdin, Raam; Rahav, Saar

    2018-04-01

    The main thread that links classical thermodynamics and the thermodynamics of small quantum systems is the celebrated Clausius inequality form of the second law. However, its application to small quantum systems suffers from two cardinal problems. (i) The Clausius inequality does not hold when the system and environment are initially correlated—a commonly encountered scenario in microscopic setups. (ii) In some other cases, the Clausius inequality does not provide any useful information (e.g., in dephasing scenarios). We address these deficiencies by developing the notion of global passivity and employing it as a tool for deriving thermodynamic inequalities on observables. For initially uncorrelated thermal environments the global passivity framework recovers the Clausius inequality. More generally, global passivity provides an extension of the Clausius inequality that holds even in the presences of strong initial system-environment correlations. Crucially, the present framework provides additional thermodynamic bounds on expectation values. To illustrate the role of the additional bounds, we use them to detect unaccounted heat leaks and weak feedback operations ("Maxwell demons") that the Clausius inequality cannot detect. In addition, it is shown that global passivity can put practical upper and lower bounds on the buildup of system-environment correlations for dephasing interactions. Our findings are highly relevant for experiments in various systems such as ion traps, superconducting circuits, atoms in optical cavities, and more.

  12. Soil gas screening for chlorinated solvents at three contaminated karst sites in Tennessee

    USGS Publications Warehouse

    Wolfe, W.J.; Williams, S.D.

    2002-01-01

    Soil gas was sampled using active sampling techniques and passive collectors at three sites in Tennessee to evaluate the effectiveness of these techniques for locating chlorinated solvent sources and flowpaths in karst aquifers. Actively collected soil gas samples were analyzed in the field with a portable gas chromatograph, and the passive soil gas collectors were analyzed in the lab with gas chromatography/mass spectrometry. Results of the sampling indicate that the effectiveness of both techniques is highly dependent on the distribution of the contaminants in the subsurface, the geomorphic and hydrogeologic characteristics of the site, and, in one case, on seasonal conditions. Both active and passive techniques identified areas of elevated subsurface chlorinated solvent concentrations at a landfill site where contamination remains concentrated in the regolith. Neither technique detected chlorinated solvents known to be moving in the bedrock at a manufacturing site characterized by thick regolith and an absence of surficial karst features. Passive soil gas sampling had varied success detecting flowpaths for chloroform in the bedrock at a train derailment site characterized by shallow regolith and abundant surficial karst features. At the train derailment site, delineation of the contaminant flowpath through passive soil gas sampling was stronger and more detailed under Winter conditions than summer.

  13. Over/Undervoltage and Undervoltage Shift of Hybrid Islanding Detection Method of Distributed Generation

    PubMed Central

    Premrudeepreechacharn, Suttichai

    2015-01-01

    The mainly used local islanding detection methods may be classified as active and passive methods. Passive methods do not perturb the system but they have larger nondetection zones, whereas active methods have smaller nondetection zones but they perturb the system. In this paper, a new hybrid method is proposed to solve this problem. An over/undervoltage (passive method) has been used to initiate an undervoltage shift (active method), which changes the undervoltage shift of inverter, when the passive method cannot have a clear discrimination between islanding and other events in the system. Simulation results on MATLAB/SIMULINK show that over/undervoltage and undervoltage shifts of hybrid islanding detection method are very effective because they can determine anti-islanding condition very fast. ΔP/P > 38.41% could determine anti-islanding condition within 0.04 s; ΔP/P < −24.39% could determine anti-islanding condition within 0.04 s; −24.39% ≤ ΔP/P ≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of −24.39% ≤ ΔP/P ≤ 38.41% at which the control system of inverter injected a signal of undervoltage shift as necessary to check if the occurrence condition was an islanding condition or not. PMID:25879064

  14. Using paired visual and passive acoustic surveys to estimate passive acoustic detection parameters for harbor porpoise abundance estimates.

    PubMed

    Jacobson, Eiren K; Forney, Karin A; Barlow, Jay

    2017-01-01

    Passive acoustic monitoring is a promising approach for monitoring long-term trends in harbor porpoise (Phocoena phocoena) abundance. Before passive acoustic monitoring can be implemented to estimate harbor porpoise abundance, information about the detectability of harbor porpoise is needed to convert recorded numbers of echolocation clicks to harbor porpoise densities. In the present study, paired data from a grid of nine passive acoustic click detectors (C-PODs, Chelonia Ltd., United Kingdom) and three days of simultaneous aerial line-transect visual surveys were collected over a 370 km 2 study area. The focus of the study was estimating the effective detection area of the passive acoustic sensors, which was defined as the product of the sound production rate of individual animals and the area within which those sounds are detected by the passive acoustic sensors. Visually estimated porpoise densities were used as informative priors in a Bayesian model to solve for the effective detection area for individual harbor porpoises. This model-based approach resulted in a posterior distribution of the effective detection area of individual harbor porpoises consistent with previously published values. This technique is a viable alternative for estimating the effective detection area of passive acoustic sensors when other experimental approaches are not feasible.

  15. Contributing to shipping container security: can passive sensors bring a solution?

    PubMed

    Janssens-Maenhout, G; De Roo, F; Janssens, W

    2010-02-01

    Illicit trafficking of fissionable material in container cargoes is recognized as a potential weakness in Nuclear Security. Triggered by the attacks of 11 September 2001, measures were undertaken to enhance maritime security in extension to the Safety Of Life At Sea Convention and in line with the US Container Security Initiatives. Effective detection techniques are needed that allow the inspector to intercept illicit trafficking of nuclear weapons components or components of other nuclear explosive devices. Many security measures focus on active interrogation of the container content by X-ray scan, which might be extended with the newly developed tagged neutron inspection system. Both active interrogation techniques can, with the current huge volume of container traffic, only be applied to a limited number of selected containers. The question arises whether a passive detection technique can offer an alternative solution. This study investigates if containers equipped with a small passive detector will register during transport the neutron irradiation by fissionable material such as plutonium in a measurable way. In practice, 4/5 of the containers are about 1/8 filled with hydrogenous material and undergo a typical 2 months route. For this reference case, it was found that the most compatible passive detector would be an activation foil of iridium. Monte-Carlo simulations showed that for the reference case the activity of a 250 microm thin foil with 6 cm(2) cross-section would register 1.2 Bq when it is irradiated by a significant quantity of Reactor-Grade PuO(2). However this activity drops with almost two orders of magnitude for other fillings and other isotopic compositions and forms of the Pu-source. The procedure of selecting the target material for Pu detection is detailed with the theoretical methods, in order to be useful for other applications. Moreover the value of such additional passive sensors for securing maritime container transport is situated within the global framework of the First, Second and Third Line of Defense against illicit trafficking. Copyright 2009 Elsevier Ltd. All rights reserved.

  16. Developing a Passive Acoustic Monitoring Network for Harbor Porpoise in California

    NASA Astrophysics Data System (ADS)

    Jacobson, Eiren Kate

    Assessing the abundance of and trends in whale, dolphin, and porpoise (cetacean) populations using traditional visual methods can be challenging due primarily to their limited availability at the surface of the ocean. As a result, researchers are increasingly interested in incorporating non-visual and remote observations to improve cetacean population assessments. Passive acoustic monitoring (PAM) can complement or replace visual surveys for cetaceans that produce echolocation clicks, whistles, and other vocalizations. My doctoral dissertation is focused on developing methods to improve PAM of cetaceans. I used the Monterey Bay population of harbor porpoise (Phocoena phocoena ) as a case study for methods development. In Chapter 2, I used passive acoustic data to document that harbor porpoises avoid bottlenose dolphins (Tursiops truncatus) in nearshore Monterey Bay. In Chapter 3, I investigated whether different passive acoustic instruments could be used to monitor harbor porpoise. I recorded harbor porpoise echolocation clicks simultaneously on two different passive acoustic instruments and compared the number and peak frequency of echolocation signals recorded on the two instruments. I found that the number of echolocation clicks was highly correlated between instruments but that the peak frequency of echolocation clicks was not well-correlated, suggesting that some instruments may not be capable of discriminating harbor porpoise echolocation clicks in regions where multiple species with similar echolocation signals are present. In Chapter 4, I used paired visual and passive acoustic surveys to estimate the effective detection area of the passive acoustic sensors in a Bayesian framework. This approach resulted in a posterior distribution of the effective detection area that was consistent with previously published values. In Chapter 5, I used aerial survey and passive acoustic data in a simulation framework to investigate the statistical power of different passive acoustic network designs and hypothetical changes in harbor porpoise abundance. As a whole, this dissertation used an applied approach to methods development to advance the use of PAM for cetaceans.

  17. Analysis of passive acoustic ranging of helicopters from the joint acoustic propagation experiment

    NASA Technical Reports Server (NTRS)

    Carnes, Benny L.; Morgan, John C.

    1993-01-01

    For more than twenty years, personnel of the U.S.A.E. Waterways Experiment Station (WES) have been performing research dealing with the application of sensors for detection of military targets. The WES research has included the use of seismic, acoustic, magnetic, and other sensors to detect, track, and classify military ground targets. Most of the WES research has been oriented toward the employment of such sensors in a passive mode. Techniques for passive detection are of particular interest in the Army because of the advantages over active detection. Passive detection methods are not susceptible to interception, detection, jamming, or location of the source by the threat. A decided advantage for using acoustic and seismic sensors for detection in tactical situations is the non-line-of-sight capability; i.e., detection of low flying helicopters at long distances without visual contact. This study was conducted to analyze the passive acoustic ranging (PAR) concept using a more extensive data set from the Joint Acoustic Propagation Experiment (JAPE).

  18. Development Of An In Situ Passive Sampler For The Detection And Remediation of Explosive Compounds

    DTIC Science & Technology

    2016-06-07

    FINAL REPORT Development of an In Situ Passive Sampler for the Detection and Remediation of Explosive Compounds SERDP Project ER-2539 MAY 2016...DATES COVERED (From - To) 4/24/15 – 12/1/2016 4. TITLE AND SUBTITLE Development of an In Situ Passive Sampler for the Detection and Remediation of...SUBJECT TERMS Passive samplers, Ethylene vinyl acetate, EVA sampler, Munitions, Monitoring, Remediation , Marine, Sediments 16. SECURITY

  19. A modular microfluidic architecture for integrated biochemical analysis.

    PubMed

    Shaikh, Kashan A; Ryu, Kee Suk; Goluch, Edgar D; Nam, Jwa-Min; Liu, Juewen; Thaxton, C Shad; Chiesl, Thomas N; Barron, Annelise E; Lu, Yi; Mirkin, Chad A; Liu, Chang

    2005-07-12

    Microfluidic laboratory-on-a-chip (LOC) systems based on a modular architecture are presented. The architecture is conceptualized on two levels: a single-chip level and a multiple-chip module (MCM) system level. At the individual chip level, a multilayer approach segregates components belonging to two fundamental categories: passive fluidic components (channels and reaction chambers) and active electromechanical control structures (sensors and actuators). This distinction is explicitly made to simplify the development process and minimize cost. Components belonging to these two categories are built separately on different physical layers and can communicate fluidically via cross-layer interconnects. The chip that hosts the electromechanical control structures is called the microfluidic breadboard (FBB). A single LOC module is constructed by attaching a chip comprised of a custom arrangement of fluid routing channels and reactors (passive chip) to the FBB. Many different LOC functions can be achieved by using different passive chips on an FBB with a standard resource configuration. Multiple modules can be interconnected to form a larger LOC system (MCM level). We demonstrated the utility of this architecture by developing systems for two separate biochemical applications: one for detection of protein markers of cancer and another for detection of metal ions. In the first case, free prostate-specific antigen was detected at 500 aM concentration by using a nanoparticle-based bio-bar-code protocol on a parallel MCM system. In the second case, we used a DNAzyme-based biosensor to identify the presence of Pb(2+) (lead) at a sensitivity of 500 nM in <1 nl of solution.

  20. 26 CFR 1.1398-1 - Treatment of passive activity losses and passive activity credits in individuals' title 11 cases.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 11 2011-04-01 2011-04-01 false Treatment of passive activity losses and passive activity credits in individuals' title 11 cases. 1.1398-1 Section 1.1398-1 Internal Revenue... (CONTINUED) Rules Relating to Individuals' Title 11 Cases § 1.1398-1 Treatment of passive activity losses and...

  1. 26 CFR 1.1398-1 - Treatment of passive activity losses and passive activity credits in individuals' title 11 cases.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Treatment of passive activity losses and passive... to Individuals' Title 11 Cases § 1.1398-1 Treatment of passive activity losses and passive activity... and rules of general application. For purposes of this section— (1) Passive activity and former...

  2. Passive Impact Damage Detection of Fiber Glass Composite Panels

    DTIC Science & Technology

    2013-12-19

    PASSIVE IMPACT DAMAGE DETECTION OF FIBER GLASS COMPOSITE PANELS. By BRUNO ZAMORANO-SENDEROS A dissertation...COVERED 04-11-2012 to 10-12-2013 4. TITLE AND SUBTITLE PASSIVE IMPACT DAMAGE DETECTION OF FIBER GLASS COMPOSITE PANELS 5a. CONTRACT NUMBER 5b...process. .................................... 31 Figure 3-8 Sensor attached to the fiber glass fabric

  3. Enhanced passive screening and diagnosis for gambiense human African trypanosomiasis in north-western Uganda – Moving towards elimination

    PubMed Central

    Bessell, Paul Richard; Ndung’u, Joseph Mathu

    2017-01-01

    Introduction The incidence of gambiense human African trypanosomiasis (gHAT) in Uganda has been declining, from 198 cases in 2008, to only 20 in 2012. Interruption of transmission of the disease by early diagnosis and treatment is core to the control and eventual elimination of gHAT. Until recently, the format of available screening tests had restricted screening and diagnosis to central health facilities (passive screening). We describe a novel strategy that is contributing to elimination of gHAT in Uganda through expansion of passive screening to the entire population at risk. Methodology / Principal findings In this strategy, patients who are clinically suspected of having gHAT at primary health facilities are screened using a rapid diagnostic test (RDT), followed by parasitological confirmation at strategically located microscopy centres. For patients who are positive with the RDT and negative by microscopy, blood samples undergo further testing using loop-mediated isothermal amplification (LAMP), a molecular test that detects parasite DNA. LAMP positive patients are considered strong suspects, and are re-evaluated by microscopy. Location and upgrading of facilities to perform microscopy and LAMP was informed by results of georeferencing and characterization of all public healthcare facilities in the 7 gHAT endemic districts in Uganda. Three facilities were upgraded to perform RDTs, microscopy and LAMP, 9 to perform RDTs and microscopy, and 200 to screen patients with RDTs. This reduced the distance that a sick person must travel to be screened for gHAT to a median distance of 2.5km compared to 23km previously. In this strategy, 9 gHAT cases were diagnosed in 2014, and 4 in 2015. Conclusions This enhanced passive screening strategy for gHAT has enabled full coverage of the population at risk, and is being replicated in other gHAT endemic countries. The improvement in case detection is making elimination of the disease in Uganda an imminent possibility. PMID:29023573

  4. Propagation of narrow-band-high-frequency clicks: measured and modeled transmission loss of porpoise-like clicks in porpoise habitats.

    PubMed

    DeRuiter, Stacy L; Hansen, Michael; Koopman, Heather N; Westgate, Andrew J; Tyack, Peter L; Madsen, Peter T

    2010-01-01

    Estimating the range at which harbor porpoises can detect prey items and environmental objects is integral to understanding their biosonar. Understanding the ranges at which they can use echolocation to detect and avoid obstacles is particularly important for strategies to reduce bycatch. Transmission loss (TL) during acoustic propagation is an important determinant of those detection ranges, and it also influences animal detection functions used in passive acoustic monitoring. However, common assumptions regarding TL have rarely been tested. Here, TL of synthetic porpoise clicks was measured in porpoise habitats in Canada and Denmark, and field data were compared with spherical spreading law and ray-trace (Bellhop) model predictions. Both models matched mean observations quite well in most cases, indicating that a spherical spreading law can usually provide an accurate first-order estimate of TL for porpoise sounds in porpoise habitat. However, TL varied significantly (+/-10 dB) between sites and over time in response to variability in seafloor characteristics, sound-speed profiles, and other short-timescale environmental fluctuations. Such variability should be taken into account in estimates of the ranges at which porpoises can communicate acoustically, detect echolocation targets, and be detected via passive acoustic monitoring.

  5. Determinants of Cancer Early Detection Behaviors:Application of Protection Motivation Theory.

    PubMed

    Rahaei, Zohreh; Ghofranipour, Fazlollah; Morowatisharifabad, Mohammad Ali; Mohammadi, Eesa

    2015-01-01

    Cancer is account for 13% of all deaths around the world and is the third cause of mortality in Iran. More than one third of these cases are pre-ventable and about 33% are curable with early detection. The aim of this study was to determine the predictors of cancer early detection (CED) behaviors applying Protection Motivation Theory (PMT). In this cross-sectional study, cluster sampling method was employed to recruit 260 individuals of above 20 years old in Yazd, Iran and a researcher designed questionnaire was completed through interviews for each of the respondents. PMT theoretical variables and CED behaviors were the basis of data collection procedure. Participants acquired 64.47% of the protection motivation, 30.97% of the passive and 45.64% of the active behaviors‟ possible scores. Theory constructs predicted 19.8%, 15.6% and 9.6% of the variations for protection motivation, passive and active behavior respectively. Protection motivation was responsible for 3.6% of passive and 8% of active behaviors‟ variations. Considering the scarceness of CED behaviors and the applicability of PMT in predicting these behaviors, utilization of the PMT‟s constructs in any interventional programs to accelerate CED behaviors could be an alternate methodological choice in the cancer control initiatives.

  6. Vibrational spectroscopy standoff detection of threat chemicals

    NASA Astrophysics Data System (ADS)

    Ortiz-Rivera, William; Pacheco-Londoño, Leonardo C.; Castro-Suarez, John R.; Felix-Rivera, Hilsamar; Hernandez-Rivera, Samuel P.

    2011-06-01

    Spectroscopy based standoff detection systems: Raman and FTIR have been tested for detection of threat chemicals, including highly energetic materials, homemade explosives, explosives formulations and high explosives mixtures. Other threat chemicals studied included toxic industrial compounds (TIC) and chemical agent simulants. Microorganisms and biological threat agent simulants have also been detected at standoff distances. Open Path FTIR has been used to detect vapors and chemicals deposited on metal surfaces at μg/cm2 levels at distances as far as 30 m in active mode and 60 m in passive mode. In the case of Raman telescope, standoff distances for acetonitrile and ammonium nitrate were 140 m.

  7. Potential Application of Airborne Passive Microwave Observations for Monitoring Inland Flooding Caused by Tropical Cyclones

    NASA Technical Reports Server (NTRS)

    Hood, Robbie E.; Radley, C.D.; LaFontaine, F.J.

    2008-01-01

    Inland flooding from tropical cyclones can be a significant factor in storm-related deaths in the United States and other countries. Information collected during NASA tropical cyclone field studies suggest surface water and flooding induced by tropical cyclone precipitation can be detected and therefore monitored using passive microwave airborne radiometers. In particular, the 10.7 GHz frequency of the NASA Advanced Microwave Precipitation Radiometer (AMPR) flown on the NASA ER-2 has demonstrated high resolution detection of anomalous surface water and flooding in numerous situations. This presentation will highlight the analysis of three cases utilizing primarily satellite and airborne radiometer data. Radiometer data from the 1998 Third Convection and Moisture Experiment (CAMEX-3) are utilized to detect surface water during landfalling Hurricane Georges in both the Dominican Republic and Louisiana. A third case is landfalling Tropical Storm Gert in Eastern Mexico during the Tropical Cloud Systems and Processes (TCSP) experiment in 2005. AMPR data are compared to topographic data and vegetation indices to evaluate the significance of the surface water signature visible in the 10.7 GHz information. The results of this study suggest the benefit of an aircraft 10 GHz radiometer to provide real-time observations of surface water conditions as part of a multi-sensor flood monitoring network.

  8. Hemoglobin E and Glucose-6-Phosphate Dehydrogenase Deficiency and Plasmodium falciparum Malaria in the Chittagong Hill Districts of Bangladesh.

    PubMed

    Shannon, Kerry L; Ahmed, Sabeena; Rahman, Hafizur; Prue, Chai S; Khyang, Jacob; Ram, Malathi; Haq, M Zahirul; Chowdhury, Ashish; Akter, Jasmin; Glass, Gregory E; Shields, Timothy; Nyunt, Myaing M; Khan, Wasif A; Sack, David A; Sullivan, David J

    2015-08-01

    Hemoglobin E is largely confined to south and southeast Asia. The association between hemoglobin E (HbE) and malaria is less clear than that of hemoglobin S and C. As part of a malaria study in the Chittagong Hill Districts of Bangladesh, an initial random sample of 202 individuals showed that 39% and 49% of Marma and Khyang ethnic groups, respectively, were positive for either heterozygous or homozygous hemoglobin E. In this group, 6.4% were also found to be severely deficient and 35% mildly deficient for glucose-6-phosphate dehydrogenase (G6PD). In a separate Plasmodium falciparum malaria case-uninfected control study, the odds of having homozygous hemoglobin E (HbEE) compared with normal hemoglobin (HbAA) were higher among malaria cases detected by passive surveillance than age and location matched uninfected controls (odds ratio [OR] = 5.0, 95% confidence interval [CI] = 1.07-46.93). The odds of heterozygous hemoglobin E (HbAE) compared with HbAA were similar between malaria cases and uninfected controls (OR = 0.71, 95% CI = 0.42-1.19). No association by hemoglobin type was found in the initial parasite density or the proportion parasite negative after 2 days of artemether/lumefantrine treatment. HbEE, but not HbAE status was associated with increased passive case detection of malaria. © The American Society of Tropical Medicine and Hygiene.

  9. Passive Detection of Gases in the Atmosphere. Case Study: Remote Sensing of SO(2) in the UV Using LINUS

    DTIC Science & Technology

    2002-12-01

    COSPEC and FLYSPEC. (From: Mares, 2002) 32 Figure 4.13. FLYSPEC sample data frame collected at Kilauea Volcano , Hawaii in March 2002. (From: Mares...March 2002 at Kilauea Volcano , Hawaii . (From: Mares, 2002) .................. 33 Figure 4.15. UV sensors used in the detection of volcanic SO2. (From... Kilauea Volcano , Hawaii from 1995 to 1997 showed that the vehicle-based measurements were 1.3-2 times greater than the tripod-based. That

  10. Spatio-temporal distribution of injured elephants in Masai Mara and the putative negative and positive roles of the local community.

    PubMed

    Mijele, Domnic; Obanda, Vincent; Omondi, Patrick; Soriguer, Ramón C; Gakuya, Francis; Otiende, Moses; Hongo, Peter; Alasaad, Samer

    2013-01-01

    Very few studies have ever focused on the elephants that are wounded or killed as local communities attempt to scare these animals away from their settlements and farms, or on the cases in which local people take revenge after elephants have killed or injured humans. On the other hand, local communities live in close proximity to elephants and hence can play a positive role in elephant conservation by informing the authorities of the presence of injured elephants. Between 2007 and 2011, 129 elephants were monitored in Masai Mara (Kenya), of which 54 had various types of active (intentionally caused) or passive (non-intentionally caused) injuries. Also studied were 75 random control samples of apparently unaffected animals. The observed active injuries were as expected biased by age, with adults suffering more harm; on the other hand, no such bias was observed in the case of passive injuries. Bias was also observed in elephant sex since more males than females were passively and actively injured. Cases of passive and active injuries in elephants were negatively related to the proximity to roads and farms; the distribution of injured elephants was not affected by the presence of either human settlements or water sources. Overall more elephants were actively injured during the dry season than the wet season as expected. Local communities play a positive role by informing KWS authorities of the presence of injured elephants and reported 43% of all cases of injured elephants. Our results suggest that the negative effect of local communities on elephants could be predicted by elephant proximity to farms and roads. In addition, local communities may be able to play a more positive role in elephant conservation given that they are key informants in the early detection of injured elephants.

  11. Use of passive scalar tagging for the study of coherent structures in the plane mixing layer

    NASA Technical Reports Server (NTRS)

    Ramaprian, B. R.; Sandham, N. D.; Mungal, M. G.; Reynolds, W. C.

    1988-01-01

    Data obtained from the numerical simulation of a 2-D mixing layer were used to study the feasibility of using the instantaneous concentration of a passive scalar for detecting the typical coherent structures in the flow. The study showed that this technique works quite satisfactorily and yields results similar to those that can be obtained by using the instantaneous vorticity for structure detection. Using the coherent events educed by the scalar conditioning technique, the contribution of the coherent events to the total turbulent momentum and scalar transport was estimated. It is found that the contribution from the typical coherent events is of the same order as that of the time-mean value. However, the individual contributions become very large during the pairing of these structures. The increase is particularly spectacular in the case of the Reynolds shear stress.

  12. False-positive result when a diphenylcarbazide spot test is used on trivalent chromium-passivated zinc surfaces.

    PubMed

    Reveko, Valeriia; Lampert, Felix; Din, Rameez U; Thyssen, Jacob P; Møller, Per

    2018-05-01

    A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. A colorimetric DPC spot test was used for the initial detection of hexavalent chromium on new and 1-year-aged trivalent chromium-passivated zinc surfaces. Then, X-ray photoelectron spectroscopy (XPS) was performed for all samples. The DPC spot test indicated the presence of hexavalent chromium in aged, but not new, trivalent chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent chromium-passivated zinc surface. Further validation of the use of the DPC test for chromium-containing metallic surfaces is required. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. WiFi-Based Real-Time Calibration-Free Passive Human Motion Detection.

    PubMed

    Gong, Liangyi; Yang, Wu; Man, Dapeng; Dong, Guozhong; Yu, Miao; Lv, Jiguang

    2015-12-21

    With the rapid development of WLAN technology, wireless device-free passive human detection becomes a newly-developing technique and holds more potential to worldwide and ubiquitous smart applications. Recently, indoor fine-grained device-free passive human motion detection based on the PHY layer information is rapidly developed. Previous wireless device-free passive human detection systems either rely on deploying specialized systems with dense transmitter-receiver links or elaborate off-line training process, which blocks rapid deployment and weakens system robustness. In the paper, we explore to research a novel fine-grained real-time calibration-free device-free passive human motion via physical layer information, which is independent of indoor scenarios and needs no prior-calibration and normal profile. We investigate sensitivities of amplitude and phase to human motion, and discover that phase feature is more sensitive to human motion, especially to slow human motion. Aiming at lightweight and robust device-free passive human motion detection, we develop two novel and practical schemes: short-term averaged variance ratio (SVR) and long-term averaged variance ratio (LVR). We realize system design with commercial WiFi devices and evaluate it in typical multipath-rich indoor scenarios. As demonstrated in the experiments, our approach can achieve a high detection rate and low false positive rate.

  14. WiFi-Based Real-Time Calibration-Free Passive Human Motion Detection †

    PubMed Central

    Gong, Liangyi; Yang, Wu; Man, Dapeng; Dong, Guozhong; Yu, Miao; Lv, Jiguang

    2015-01-01

    With the rapid development of WLAN technology, wireless device-free passive human detection becomes a newly-developing technique and holds more potential to worldwide and ubiquitous smart applications. Recently, indoor fine-grained device-free passive human motion detection based on the PHY layer information is rapidly developed. Previous wireless device-free passive human detection systems either rely on deploying specialized systems with dense transmitter-receiver links or elaborate off-line training process, which blocks rapid deployment and weakens system robustness. In the paper, we explore to research a novel fine-grained real-time calibration-free device-free passive human motion via physical layer information, which is independent of indoor scenarios and needs no prior-calibration and normal profile. We investigate sensitivities of amplitude and phase to human motion, and discover that phase feature is more sensitive to human motion, especially to slow human motion. Aiming at lightweight and robust device-free passive human motion detection, we develop two novel and practical schemes: short-term averaged variance ratio (SVR) and long-term averaged variance ratio (LVR). We realize system design with commercial WiFi devices and evaluate it in typical multipath-rich indoor scenarios. As demonstrated in the experiments, our approach can achieve a high detection rate and low false positive rate. PMID:26703612

  15. Results from the dynamic albedo of neutrons (DAN) passive mode experiment: Yellowknife Bay to Amargosa Valley (Sols 201-753)

    NASA Astrophysics Data System (ADS)

    Tate, C. G.; Moersch, J.; Mitrofanov, I.; Litvak, M.; Bellutta, P.; Boynton, W. V.; Drake, D.; Ehresmann, B.; Fedosov, F.; Golovin, D.; Hardgrove, C.; Harshman, K.; Hassler, D. M.; Jun, I.; Kozyrev, A. S.; Lisov, D.; Malakhov, A.; Ming, D. W.; Mischna, M.; Mokrousov, M.; Nikiforov, S.; Sanin, A. B.; Starr, R.; Vostrukhin, A.; Zeitlin, C.

    2018-01-01

    The Mars Science Laboratory (Curiosity rover) Dynamic Albedo of Neutrons (DAN) experiment detects neutrons for the purpose of searching for hydrogen in the shallow subsurface of Mars. DAN has two modes of operation, active and passive. In passive mode, the instrument detects neutrons produced by Galactic Cosmic Ray interactions in the atmosphere and regolith and by the rover's Multi-Mission Radioisotope Thermoelectric Generator. DAN passive data from Yellowknife Bay to Amargosa Valley (sols 201 through 753) are presented and analyzed here. Water equivalent hydrogen (WEH) estimates from this portion of Curiosity's traverse range from 0.0 wt. % up to 15.3 wt. %. Typical uncertainties on these WEH estimates are ∼0.5 wt. % but in some cases can be as high as ∼4.0 wt. % depending on the specific circumstances of a given measurement. Here we also present a new way of reporting results from the passive mode of the experiment, the DAN passive geochemical index (DPGI). This index is sensitive to some key geochemical variations, but it does not require assumptions about the abundances of high thermal neutron absorption cross section elements, which are needed to estimate WEH. DPGI variations in this section of the traverse indicate that the shallow regolith composition is changing on both the local (∼meters) and regional (∼100 s of meters) scales. This variability is thought to be representative of the diverse composition of source regions for sediments within the crater floor. Kolmogorov-Smirnov Tests on the populations of WEH estimates and DPGI values demonstrate there are statistically significant differences between nearly all of the geologic units investigated along the rover's traverse. We also present updated previous DAN passive results from Bradbury Landing to John Klein that make use of revised DAN active mode results for calibration, however, no qualitative changes in the interpretations made in Tate et al. (2015b) are incurred.

  16. [Investigation on remote measurement of air pollution by a method of infrared passive scanning imaging].

    PubMed

    Jiao, Yang; Xu, Liang; Gao, Min-Guang; Feng, Ming-Chun; Jin, Ling; Tong, Jing-Jing; Li, Sheng

    2012-07-01

    Passive remote sensing by Fourier-transform infrared (FTIR) spectrometry allows detection of air pollution. However, for the localization of a leak and a complete assessment of the situation in the case of the release of a hazardous cloud, information about the position and the distribution of a cloud is essential. Therefore, an imaging passive remote sensing system comprising an interferometer, a data acquisition and processing software, scan system, a video system, and a personal computer has been developed. The remote sensing of SF6 was done. The column densities of all directions in which a target compound has been identified may be retrieved by a nonlinear least squares fitting algorithm and algorithm of radiation transfer, and a false color image is displayed. The results were visualized by a video image, overlaid by false color concentration distribution image. The system has a high selectivity, and allows visualization and quantification of pollutant clouds.

  17. Complexity quantification of dense array EEG using sample entropy analysis.

    PubMed

    Ramanand, Pravitha; Nampoori, V P N; Sreenivasan, R

    2004-09-01

    In this paper, a time series complexity analysis of dense array electroencephalogram signals is carried out using the recently introduced Sample Entropy (SampEn) measure. This statistic quantifies the regularity in signals recorded from systems that can vary from the purely deterministic to purely stochastic realm. The present analysis is conducted with an objective of gaining insight into complexity variations related to changing brain dynamics for EEG recorded from the three cases of passive, eyes closed condition, a mental arithmetic task and the same mental task carried out after a physical exertion task. It is observed that the statistic is a robust quantifier of complexity suited for short physiological signals such as the EEG and it points to the specific brain regions that exhibit lowered complexity during the mental task state as compared to a passive, relaxed state. In the case of mental tasks carried out before and after the performance of a physical exercise, the statistic can detect the variations brought in by the intermediate fatigue inducing exercise period. This enhances its utility in detecting subtle changes in the brain state that can find wider scope for applications in EEG based brain studies.

  18. Passive Standoff Detection of Chemical Warfare Agents on Surfaces

    NASA Astrophysics Data System (ADS)

    Thériault, Jean-Marc; Puckrin, Eldon; Hancock, Jim; Lecavalier, Pierre; Lepage, Carmela Jackson; Jensen, James O.

    2004-11-01

    Results are presented on the passive standoff detection and identification of chemical warfare (CW) liquid agents on surfaces by the Fourier-transform IR radiometry. This study was performed during surface contamination trials at Defence Research and Development Canada-Suffield in September 2002. The goal was to verify that passive long-wave IR spectrometric sensors can potentially remotely detect surfaces contaminated with CW agents. The passive sensor, the Compact Atmospheric Sounding Interferometer, was used in the trial to obtain laboratory and field measurements of CW liquid agents, HD and VX. The agents were applied to high-reflectivity surfaces of aluminum, low-reflectivity surfaces of Mylar, and several other materials including an armored personnel carrier. The field measurements were obtained at a standoff distance of 60 m from the target surfaces. Results indicate that liquid contaminant agents deposited on high-reflectivity surfaces can be detected, identified, and possibly quantified with passive sensors. For low-reflectivity surfaces the presence of the contaminants can usually be detected; however, their identification based on simple correlations with the absorption spectrum of the pure contaminant is not possible.

  19. Automated aural classification used for inter-species discrimination of cetaceans.

    PubMed

    Binder, Carolyn M; Hines, Paul C

    2014-04-01

    Passive acoustic methods are in widespread use to detect and classify cetacean species; however, passive acoustic systems often suffer from large false detection rates resulting from numerous transient sources. To reduce the acoustic analyst workload, automatic recognition methods may be implemented in a two-stage process. First, a general automatic detector is implemented that produces many detections to ensure cetacean presence is noted. Then an automatic classifier is used to significantly reduce the number of false detections and classify the cetacean species. This process requires development of a robust classifier capable of performing inter-species classification. Because human analysts can aurally discriminate species, an automated aural classifier that uses perceptual signal features was tested on a cetacean data set. The classifier successfully discriminated between four species of cetaceans-bowhead, humpback, North Atlantic right, and sperm whales-with 85% accuracy. It also performed well (100% accuracy) for discriminating sperm whale clicks from right whale gunshots. An accuracy of 92% and area under the receiver operating characteristic curve of 0.97 were obtained for the relatively challenging bowhead and humpback recognition case. These results demonstrated that the perceptual features employed by the aural classifier provided powerful discrimination cues for inter-species classification of cetaceans.

  20. Wireless SAW passive tag temperature measurement in the collision case

    NASA Astrophysics Data System (ADS)

    Sorokin, A.; Shepeta, A.; Wattimena, M.

    2018-04-01

    This paper describes temperature measurement in the multisensor systems based on the radio-frequency identification SAW passive tags which are currently applied in the electric power systems and the switchgears. Different approaches of temperature measurement in the collision case are shown here. The study is based on the tag model with specific topology, which allows us to determine temperature through the response signal with time-frequency information. This research considers the collision case for several passive tags as the temperature sensors which are placed in the switchgear. This research proposal is to analyze the possibility of using several SAW passive sensors in the collision case. We consider the using of the different typical elements for passive surface acoustic wave tag which applies as an anticollision passive sensor. These wireless sensors based on the surface acoustic waves tags contain specifically coded structures. This topology makes possible the reliability of increasing tag identification and the temperature measurement in the collision case. As the results for this case we illustrate simultaneous measurement of at least six sensors.

  1. Glider-based Passive Acoustic Monitoring Techniques in the Southern California Region & West Coast Naval Training Range Demonstration of Glider-based Passive Acoustic Monitoring

    DTIC Science & Technology

    2012-09-30

    generalized power-law detection algorithm for humpback whale vocalizations. J. Acous. Soc. Am. 131(4), 2682-2699. Roch, M. A., H. Klinck, S...Heaney (2012b). Site specific probability of passive acoustic detection of humpback whale calls from single fixed hydrophones. J. Acous. Soc. Am...monitoring: Correcting humpback call detections for site-specific and time-dependent environmental characteristics . JASA Express Letters, submitted October, 2012, 5 pgs plus 3 figs.

  2. Prospects of passive radio detection of a subsurface ocean on Europa with a lander

    NASA Astrophysics Data System (ADS)

    Romero-Wolf, Andrew; Schroeder, Dustin M.; Ries, Paul; Bills, Bruce G.; Naudet, Charles; Scott, Bryan R.; Treuhaft, Robert; Vance, Steve

    2016-09-01

    We estimate the sensitivity of a lander-based instrument for the passive radio detection of a subsurface ocean beneath the ice shell of Europa, expected to be between 3 km and 30 km thick, using Jupiter's decametric radiation. A passive technique was previously studied for an orbiter. Using passive detection in a lander platform provides a point measurement with significant improvements due to largely reduced losses from surface roughness effects, longer integration times, and diminished dispersion due to ionospheric effects allowing operation at lower frequencies and a wider band. A passive sounder on-board a lander provides a low resource instrument sensitive to subsurface ocean at Europa up to depths of 6.9 km for high loss ice (16 dB/km two-way attenuation rate) and 69 km for pure ice (1.6 dB/km).

  3. Detection of Rare Antimicrobial Resistance Profiles by Active and Passive Surveillance Approaches

    PubMed Central

    Mather, Alison E.; Reeve, Richard; Mellor, Dominic J.; Matthews, Louise; Reid-Smith, Richard J.; Haydon, Daniel T.; Reid, Stuart W. J.

    2016-01-01

    Antimicrobial resistance (AMR) surveillance systems are generally not specifically designed to detect emerging resistances and usually focus primarily on resistance to individual drugs. Evaluating the diversity of resistance, using ecological metrics, allows the assessment of sampling protocols with regard to the detection of rare phenotypes, comprising combinations of resistances. Surveillance data of phenotypic AMR of Canadian poultry Salmonella Heidelberg and swine Salmonella Typhimurium var. 5- were used to contrast active (representative isolates derived from healthy animals) and passive (diagnostic isolates) surveillance and assess their suitability for detecting emerging resistance patterns. Although in both datasets the prevalences of resistance to individual antimicrobials were not significantly different between the two surveillance systems, analysis of the diversity of entire resistance phenotypes demonstrated that passive surveillance of diagnostic isolates detected more unique phenotypes. Whilst the most appropriate surveillance method will depend on the relevant objectives, under the conditions of this study, passive surveillance of diagnostic isolates was more effective for the detection of rare and therefore potentially emerging resistance phenotypes. PMID:27391966

  4. Real-time reporting of baleen whale passive acoustic detections from ocean gliders.

    PubMed

    Baumgartner, Mark F; Fratantoni, David M; Hurst, Thomas P; Brown, Moira W; Cole, Tim V N; Van Parijs, Sofie M; Johnson, Mark

    2013-09-01

    In the past decade, much progress has been made in real-time passive acoustic monitoring of marine mammal occurrence and distribution from autonomous platforms (e.g., gliders, floats, buoys), but current systems focus primarily on a single call type produced by a single species, often from a single location. A hardware and software system was developed to detect, classify, and report 14 call types produced by 4 species of baleen whales in real time from ocean gliders. During a 3-week deployment in the central Gulf of Maine in late November and early December 2012, two gliders reported over 25,000 acoustic detections attributed to fin, humpback, sei, and right whales. The overall false detection rate for individual calls was 14%, and for right, humpback, and fin whales, false predictions of occurrence during 15-min reporting periods were 5% or less. Transmitted pitch tracks--compact representations of sounds--allowed unambiguous identification of both humpback and fin whale song. Of the ten cases when whales were sighted during aerial or shipboard surveys and a glider was within 20 km of the sighting location, nine were accompanied by real-time acoustic detections of the same species by the glider within ±12 h of the sighting time.

  5. Target detection using microwave irradiances from natural sources: A passive, local and global surveillance system

    NASA Technical Reports Server (NTRS)

    Stacey, J. M.

    1984-01-01

    Detection of metal objects on or near the Earth's surface was investigated using existing, passive, microwave sensors operating from Earth orbit. The range equations are derived from basic microwave principles and theories and the expressions are given explicitly to estimate the signal to noise ratio for detecting metal targets operating as bistatic scatterers. Actual measurements are made on a range of metal objects observed from orbit using existing passive microwave receiving systems. The details of the measurements and the results are tabulated and discussed. The advantages of a passive microwave sensor as it is applied to surveillance of metal objects as viewed from aerial platforms or from orbit, are examined.

  6. Passive Detection of Misbehaving Name Servers

    DTIC Science & Technology

    2013-10-01

    Passive Detection of Misbehaving Name Servers Leigh B. Metcalf Jonathan M. Spring October 2013 TECHNICAL REPORT CMU/SEI-2013-TR-010 ESC-TR...Detection of Misbehaving Name Servers 5. FUNDING NUMBERS FA8721-05-C-0003 6. AUTHOR(S) Leigh B. Metcalf and Jonathan M. Spring 7. PERFORMING

  7. Novel Application of FTIR Spectroscopy for the Passive Standoff Detection of Radiological Materials

    DTIC Science & Technology

    2006-08-01

    possibility of applying the long-wave passive standoff detection technique to the identification of radiological materials. This work is based on...infrared (FTIR) radiometry is a well-known technique for detecting and identifying chemical warfare agents. In addition to these potential threats...necessary tools and techniques available for detecting and identifying radioactive products. At present, the main detection techniques depend on methods

  8. Submarine Combat Systems Engineering Project Capstone Project

    DTIC Science & Technology

    2011-06-06

    sonar , imaging, Electronic Surveillance (ES) and communications. These sensors passively detect contacts, which emit... passive sensors is included. A Search Detect Identify Track Decide Engage Assess 3 contact can be sensed by the system as either surface or... Detect Track Avoid Search Detect Identify Track Search Engage Assess Detect Track Avoid Search • SONAR •Imagery •TC • SONAR • SONAR •EW •Imagery •ESM

  9. Sampled-data consensus in switching networks of integrators based on edge events

    NASA Astrophysics Data System (ADS)

    Xiao, Feng; Meng, Xiangyu; Chen, Tongwen

    2015-02-01

    This paper investigates the event-driven sampled-data consensus in switching networks of multiple integrators and studies both the bidirectional interaction and leader-following passive reaction topologies in a unified framework. In these topologies, each information link is modelled by an edge of the information graph and assigned a sequence of edge events, which activate the mutual data sampling and controller updates of the two linked agents. Two kinds of edge-event-detecting rules are proposed for the general asynchronous data-sampling case and the synchronous periodic event-detecting case. They are implemented in a distributed fashion, and their effectiveness in reducing communication costs and solving consensus problems under a jointly connected topology condition is shown by both theoretical analysis and simulation examples.

  10. Methodology for the passive detection and discrimination of chemical and biological aerosols

    NASA Astrophysics Data System (ADS)

    Marinelli, William J.; Shokhirev, Kirill N.; Konno, Daisei; Rossi, David C.; Richardson, Martin

    2013-05-01

    The standoff detection and discrimination of aerosolized biological and chemical agents has traditionally been addressed through LIDAR approaches, but sensor systems using these methods have yet to be deployed. We discuss the development and testing of an approach to detect these aerosols using the deployed base of passive infrared hyperspectral sensors used for chemical vapor detection. The detection of aerosols requires the inclusion of down welling sky and up welling ground radiation in the description of the radiative transfer process. The wavelength and size dependent ratio of absorption to scattering provides much of the discrimination capability. The approach to the detection of aerosols utilizes much of the same phenomenology employed in vapor detection; however, the sensor system must acquire information on non-line-of-sight sources of radiation contributing to the scattering process. We describe the general methodology developed to detect chemical or biological aerosols, including justifications for the simplifying assumptions that enable the development of a real-time sensor system. Mie scattering calculations, aerosol size distribution dependence, and the angular dependence of the scattering on the aerosol signature will be discussed. This methodology will then be applied to two test cases: the ground level release of a biological aerosol (BG) and a nonbiological confuser (kaolin clay) as well as the debris field resulting from the intercept of a cruise missile carrying a thickened VX warhead. A field measurement, conducted at the Utah Test and Training Range will be used to illustrate the issues associated with the use of the method.

  11. Datasets of Odontocete Sounds Annotated for Developing Automatic Detection Methods

    DTIC Science & Technology

    2010-12-01

    Passive acoustic detection of Minke whales (Balaenoptera acutorostrata) off the West Coast of Kauai, HI. Book of abstracts, Fourth International...Workshop on Detection , Classification and Localization of Marine Mammals using Passive Acoustics , Pavia, Italy, Sept. 10- 13, 2009, p. 57. Roch, M., Y...Mellinger, and D. Gillespie. 2010. Comparison of beaked whale detection algorithms. Applied Acoustics 71:1043-1049. 8 References

  12. The spatio-temporal dynamics of deviance and target detection in the passive and active auditory oddball paradigm: a sLORETA study.

    PubMed

    Justen, Christoph; Herbert, Cornelia

    2018-04-19

    Numerous studies have investigated the neural underpinnings of passive and active deviance and target detection in the well-known auditory oddball paradigm by means of event-related potentials (ERPs) or functional magnetic resonance imaging (fMRI). The present auditory oddball study investigates the spatio-temporal dynamics of passive versus active deviance and target detection by analyzing amplitude modulations of early and late ERPs while at the same time exploring the neural sources underling this modulation with standardized low-resolution brain electromagnetic tomography (sLORETA) . A 64-channel EEG was recorded from twelve healthy right-handed participants while listening to 'standards' and 'deviants' (500 vs. 1000 Hz pure tones) during a passive (block 1) and an active (block 2) listening condition. During passive listening, participants had to simply listen to the tones. During active listening they had to attend and press a key in response to the deviant tones. Passive and active listening elicited an N1 component, a mismatch negativity (MMN) as difference potential (whose amplitudes were temporally overlapping with the N1) and a P3 component. N1/MMN and P3 amplitudes were significantly more pronounced for deviants as compared to standards during both listening conditions. Active listening augmented P3 modulation to deviants significantly compared to passive listening, whereas deviance detection as indexed by N1/MMN modulation was unaffected by the task. During passive listening, sLORETA contrasts (deviants > standards) revealed significant activations in the right superior temporal gyrus (STG) and the lingual gyri bilaterally (N1/MMN) as well as in the left and right insulae (P3). During active listening, significant activations were found for the N1/MMN in the right inferior parietal lobule (IPL) and for the P3 in multiple cortical regions (e.g., precuneus). The results provide evidence for the hypothesis that passive as well as active deviance and target detection elicit cortical activations in spatially distributed brain regions and neural networks including the ventral attention network (VAN), dorsal attention network (DAN) and salience network (SN). Based on the temporal activation of the neural sources underlying ERP modulations, a neurophysiological model of passive and active deviance and target detection is proposed which can be tested in future studies.

  13. A comparison of passive and active acoustic sampling for a bat community impacted by White-nose syndrome

    USGS Publications Warehouse

    Coleman, Laci S.; Ford, W. Mark; Dobony, Christopher A.; Britzke, Eric R.

    2014-01-01

    In the summers of 2011 and 2012, we compared passive and active acoustic sampling for bats at 31 sites at Fort Drum Military Installation, New York. We defined active sampling as acoustic sampling that occurred in 30-min intervals between the hours of sunset and 0200 with a user present to manipulate the directionality of the microphone. We defined passive sampling as acoustic sampling that occurred over a 12-h period (1900–0700 hours) without a user present and with the microphone set in a predetermined direction. We detected seven of the nine possible species at Fort Drum, including the federally endangered Indiana bat Myotis sodalis, the proposed-for-listing northern bat M. septentrionalis, the little brown bat M. lucifugus, and the big brown bat Eptesicus fuscus, which are impacted by white-nose syndrome (WNS); and the eastern red bat Lasiurus borealis, the hoary bat L. cinereus, and the silver-haired bat Lasionycteris noctivagans, which are not known to be impacted by WNS. We did not detect two additional WNS-impacted species known to historically occur in the area: the eastern small-footed bat Myotis leibii and the tri-colored bat Perimyotis subflavus. Single-season occupancy models revealed lower detection probabilities of all detected species using active sampling versus passive sampling. Additionally, overall detection probabilities declined in detected WNS-impacted species between years. A paired t-test of simultaneous sampling on 21 occasions revealed that overall recorded foraging activity per hour was greater using active than passive sampling for big brown bats and greater using passive than active sampling for little brown bats. There was no significant difference in recorded activity between methods for other WNS-impacted species, presumably because these species have been so reduced in number that their “apparency” on the landscape is lower. Finally, a cost analysis of standard passive and active sampling protocols revealed that passive sampling is substantially more cost-effective than active sampling per hour of data collection. We recommend passive sampling over active sampling methodologies as they are defined in our study for detection probability and/or occupancy studies focused on declining bat species in areas that have experienced severe WNS-associated impacts.

  14. The comparison of detection methods of asymptomatic malaria in hypoendemic areas

    NASA Astrophysics Data System (ADS)

    Siahaan, L.; Panggabean, M.; Panggabean, Y. C.

    2018-03-01

    Malaria is still a problem that disrupts public health in North Sumatera. Late diagnosis will increase the chances of increased morbidity and mortality due to malaria. The early detection of asymptomatic malaria is one of the best efforts to reduce the transmission of the disease. Early detection is certainly must be done on suspect patients who have no malaria complaints. Passive Case Detection (PCD) methods seem hard to find asymptomatic malaria. This study was conducted to compare ACD (Active Case Detection) and PCD methods in asymptomatic malaria detection in the hypoendemic areas of malaria. ACD method is done by going to the sample based on secondary data. Meanwhile, PCD is done on samples that come to health services. Samples were taken randomly and diagnosis was confirmed by microscopic examination with 3% Giemsa staining, as gold standard of malaria diagnostics. There was a significant difference between ACD and PCD detection methods (p = 0.034), where ACD method was seen superior in detecting malaria patients in all categories, such as: clinical malaria (65.2%), asymptomatic malaria (65.1%) and submicroscopic malaria (58.5%). ACD detection methods are superior in detecting malaria sufferers, especially asymptomatic malaria sufferers.

  15. Sensor Failure Detection of FASSIP System using Principal Component Analysis

    NASA Astrophysics Data System (ADS)

    Sudarno; Juarsa, Mulya; Santosa, Kussigit; Deswandri; Sunaryo, Geni Rina

    2018-02-01

    In the nuclear reactor accident of Fukushima Daiichi in Japan, the damages of core and pressure vessel were caused by the failure of its active cooling system (diesel generator was inundated by tsunami). Thus researches on passive cooling system for Nuclear Power Plant are performed to improve the safety aspects of nuclear reactors. The FASSIP system (Passive System Simulation Facility) is an installation used to study the characteristics of passive cooling systems at nuclear power plants. The accuracy of sensor measurement of FASSIP system is essential, because as the basis for determining the characteristics of a passive cooling system. In this research, a sensor failure detection method for FASSIP system is developed, so the indication of sensor failures can be detected early. The method used is Principal Component Analysis (PCA) to reduce the dimension of the sensor, with the Squarred Prediction Error (SPE) and statistic Hotteling criteria for detecting sensor failure indication. The results shows that PCA method is capable to detect the occurrence of a failure at any sensor.

  16. [A comparative analysis of the passive electric probe detection and spectrum diagnosis of laser-induced plasma].

    PubMed

    Liu, Tong; Yang, Li-Jun; Wang, Li-Jun; Wang, Lang-Ping

    2014-02-01

    An approach to detecting laser-induced plasma using passive probe was brought up. The plasma of laser welding was studied by using a synchronous electric and spectral information acquisition system, the laser-induced plasma was detected by a passive electric probe and fiber spectrometer, the electrical signal was analyzed on the basis of the theory of plasma sheath, and the temperature of laser-induced plasma was calculated by using the method of relative spectral intensity. The analysis results from electrical signal and spectral one were compared. Calculation results of three kinds of surface circumstances, which were respectively coated by KF, TiO2 and without coating, were compared. The factors affecting the detection accuracy were studied. The results indicated that the results calculated by passive probe matched that by spectral signal basically, and the accuracy was affected by ions mass of the plasma. The designed passive electric probe can be used to reflect the continuous fluctuation of electron temperature of the generated plasma, and monitor the laser-induced plasma.

  17. Effect of ultrasonic cavitation on the diffusivity of a point defect in the passive film on formed Nb in 0.5 M HCl solution.

    PubMed

    Li, D G

    2015-11-01

    This work primarily focused on the influence of ultrasonic cavitation on the transport property of the point defect in the passive film on formed Nb in 0.5M HCl solution via electrochemical techniques based on the point defect model (PDM). The influence of ultrasonic cavitation on the composition and structure of the passive film was detected by X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). The transport property of a point defect in the passive film was characterized by the diffusivity of the point defect (D0). The influences of the ultrasonic cavitation power, passivated time and the distance between horn bottom and sample surface on D0 were analyzed. The results demonstrated that the passive film formed on Nb was an n-type semiconductor with a donor density (ND) ranging from 10(19) cm(-3) to 10(20) cm(-3) in the case of static state, while the order of ND increased one to two times by applying ultrasonic cavitation during film formation. The diffusivity of the point defect (D0) in the passive film formed on Nb at 0.5 V for 1 h in a 0.5 M HCl solution in the static state was calculated to be 9.704×10(-18) cm(2) s(-1), and it increased to 1.255×10(-16) cm(2) s(-1), 7.259×10(-16) cm(2) s(-1) and 7.296×10(-15) cm(2) s(-1) when applying the 180 W, 270 W and 450 W ultrasonic cavitation powers during film formation. D0 increased with the increment of the ultrasonic cavitation power, and decreased with the increased in formation time and distance between the horn bottom and sample surface. AES results showed the film structure and composition were changed by applying the ultrasonic cavitation. XPS results revealed that the passive film was mainly composed of Nb2O5 in the static state, and the low valence Nb-oxide (NbO) appeared in the passive film except Nb2O5 in the case of applying a 270 W ultrasonic cavitation power. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Spatio-Temporal Distribution of Injured Elephants in Masai Mara and the Putative Negative and Positive Roles of the Local Community

    PubMed Central

    Mijele, Domnic; Obanda, Vincent; Omondi, Patrick; Soriguer, Ramón C.; Gakuya, Francis; Otiende, Moses; Hongo, Peter; Alasaad, Samer

    2013-01-01

    Background Very few studies have ever focused on the elephants that are wounded or killed as local communities attempt to scare these animals away from their settlements and farms, or on the cases in which local people take revenge after elephants have killed or injured humans. On the other hand, local communities live in close proximity to elephants and hence can play a positive role in elephant conservation by informing the authorities of the presence of injured elephants. Methodology/Principal Findings Between 2007 and 2011, 129 elephants were monitored in Masai Mara (Kenya), of which 54 had various types of active (intentionally caused) or passive (non-intentionally caused) injuries. Also studied were 75 random control samples of apparently unaffected animals. The observed active injuries were as expected biased by age, with adults suffering more harm; on the other hand, no such bias was observed in the case of passive injuries. Bias was also observed in elephant sex since more males than females were passively and actively injured. Cases of passive and active injuries in elephants were negatively related to the proximity to roads and farms; the distribution of injured elephants was not affected by the presence of either human settlements or water sources. Overall more elephants were actively injured during the dry season than the wet season as expected. Local communities play a positive role by informing KWS authorities of the presence of injured elephants and reported 43% of all cases of injured elephants. Conclusions Our results suggest that the negative effect of local communities on elephants could be predicted by elephant proximity to farms and roads. In addition, local communities may be able to play a more positive role in elephant conservation given that they are key informants in the early detection of injured elephants. PMID:23936262

  19. Environmental monitoring of selected pesticides and organic chemicals in urban stormwater recycling systems using passive sampling techniques

    NASA Astrophysics Data System (ADS)

    Page, Declan; Miotliński, Konrad; Gonzalez, Dennis; Barry, Karen; Dillon, Peter; Gallen, Christie

    2014-03-01

    Water recycling via aquifers has become a valuable tool to augment urban water supplies in many countries. This study reports the first use of passive samplers for monitoring of organic micropollutants in Managed Aquifer Recharge (MAR). Five different configurations of passive samplers were deployed in a stormwater treatment wetland, groundwater monitoring wells and a recovery tank to capture a range of polar and non-polar micropollutants present in the system. The passive samplers were analysed for a suite of pesticides, polycyclic aromatic hydrocarbons (PAHs) and other chemicals. As a result, 17 pesticides and pesticide degradation products, 5 PAHs and 8 other organic chemicals including flame retardants and fragrances were detected in urban stormwater recharging Aquifer Storage and Recovery (ASR) and an Aquifer Storage Transfer and Recovery (ASTR) system. Of the pesticides detected, diuron, metolachlor and chlorpyrifos were generally detected at the highest concentrations in one or more passive samplers, whereas chlorpyrifos, diuron, metolachlor, simazine, galaxolide and triallate were detected in multiple samplers. Fluorene was the PAH detected at the highest concentration and the flame retardant Tris(1-chloro-2-propyl)phosphate was the chemical detected in the greatest abundance at all sites. The passive samplers showed different efficiencies for capture of micropollutants with the Empore disc samplers giving the most reliable results. The results indicate generally low levels of organic micropollutants in the stormwater, as the contaminants detected were present at very low ng/L levels, generally two to four orders of magnitude below the drinking water guidelines (NHMRC, 2011). The efficiency of attenuation of these organic micropollutants during MAR was difficult to determine due to variations in the source water concentrations. Comparisons were made between different samplers, to give a field-based calibration where existing lab-based calibrations were unavailable.

  20. Detection Thresholds of Falling Snow From Satellite-Borne Active and Passive Sensors

    NASA Technical Reports Server (NTRS)

    Skofronick-Jackson, Gail M.; Johnson, Benjamin T.; Munchak, S. Joseph

    2013-01-01

    There is an increased interest in detecting and estimating the amount of falling snow reaching the Earths surface in order to fully capture the global atmospheric water cycle. An initial step toward global spaceborne falling snow algorithms for current and future missions includes determining the thresholds of detection for various active and passive sensor channel configurations and falling snow events over land surfaces and lakes. In this paper, cloud resolving model simulations of lake effect and synoptic snow events were used to determine the minimum amount of snow (threshold) that could be detected by the following instruments: the W-band radar of CloudSat, Global Precipitation Measurement (GPM) Dual-Frequency Precipitation Radar (DPR)Ku- and Ka-bands, and the GPM Microwave Imager. Eleven different nonspherical snowflake shapes were used in the analysis. Notable results include the following: 1) The W-band radar has detection thresholds more than an order of magnitude lower than the future GPM radars; 2) the cloud structure macrophysics influences the thresholds of detection for passive channels (e.g., snow events with larger ice water paths and thicker clouds are easier to detect); 3) the snowflake microphysics (mainly shape and density)plays a large role in the detection threshold for active and passive instruments; 4) with reasonable assumptions, the passive 166-GHz channel has detection threshold values comparable to those of the GPM DPR Ku- and Ka-band radars with approximately 0.05 g *m(exp -3) detected at the surface, or an approximately 0.5-1.0-mm * h(exp -1) melted snow rate. This paper provides information on the light snowfall events missed by the sensors and not captured in global estimates.

  1. A habituation based approach for detection of visual changes in surveillance camera

    NASA Astrophysics Data System (ADS)

    Sha'abani, M. N. A. H.; Adan, N. F.; Sabani, M. S. M.; Abdullah, F.; Nadira, J. H. S.; Yasin, M. S. M.

    2017-09-01

    This paper investigates a habituation based approach in detecting visual changes using video surveillance systems in a passive environment. Various techniques have been introduced for dynamic environment such as motion detection, object classification and behaviour analysis. However, in a passive environment, most of the scenes recorded by the surveillance system are normal. Therefore, implementing a complex analysis all the time in the passive environment resulting on computationally expensive, especially when using a high video resolution. Thus, a mechanism of attention is required, where the system only responds to an abnormal event. This paper proposed a novelty detection mechanism in detecting visual changes and a habituation based approach to measure the level of novelty. The objective of the paper is to investigate the feasibility of the habituation based approach in detecting visual changes. Experiment results show that the approach are able to accurately detect the presence of novelty as deviations from the learned knowledge.

  2. Multi-Sensor Radiometric Study to Detect Pathologies in Historical Buildings

    NASA Astrophysics Data System (ADS)

    Del Pozo, S.; Herrero-Pascual, J.; Felipe-García, B.; Hernández-López, D.; Rodríguez-Gonzálvez, P.; González-Aguilera, D.

    2015-02-01

    This paper presents a comparative study with different remote sensing technologies to recognize pathologies in façades of historical buildings. Building materials deteriorate over the years due to different extrinsic and intrinsic agents, so assessing these diseases in a non-invasive way is crucial to help preserve them. Most of these buildings are extremely valuable and some of them have been declared monuments of cultural interest. In this way through close range remote sensing techniques, it is possible to study material pathologies in a rigorous way and in a short duration field campaign. For the investigation two different acquisition systems were applied, active and passive methods. The terrestrial laser scanner FARO Focus 3D was used as active sensor, working at the wavelength of 905 nm. For the case of passive sensors, a Nikon D-5000 and a 6- bands Mini-MCA multispectral camera (530-801 nm) were applied covering visible and near infrared spectral range. This analysis allows assessing the sensor, or sensors combination, suitability for pathologies detection, addressing the limitations according to the spatial and spectral resolution. Moreover, the pathology detection by unsupervised classification methods is addressed in order to evaluate the automation capability of this process.

  3. Analysis of RFI Statistics for Aquarius RFI Detection and Mitigation Improvements

    NASA Technical Reports Server (NTRS)

    de Matthaeis, Paolo; Soldo, Yan; Le Vine, David M.

    2016-01-01

    Aquarius is an L-band active/passive sensor designed to globally map sea surface salinity from space. Two instruments, a radar scatterometer and a radiometer, observe the same surface footprint almost simultaneously. The radiometer is the primary instrument for sensing sea surface salinity (SSS), while the scatterometer is included to provide a correction for sea surface roughness, which is a primary source of error in the salinity retrieval. Although the primary objective is the measurement of SSS, the instrument combination operates continuously, acquiring data over land and sea ice as well. An important feature of the data processing includes detection and mitigation of Radio Frequency Interference (RFI) which is done separately for both active and passive instruments. Correcting for RFI is particularly critical over ocean because of the high accuracy required in the brightness temperature measurements for SSS retrieval. It is also necessary for applications of the Aquarius data over land, where man-made interference is widespread, even though less accuracy is required in this case. This paper will provide an overview of the current status of the Aquarius RFI processing and an update on the ongoing work on the improvement of the RFI detection and mitigation performance.

  4. Using Passive Sensing to Estimate Relative Energy Expenditure for Eldercare Monitoring

    PubMed Central

    2012-01-01

    This paper describes ongoing work in analyzing sensor data logged in the homes of seniors. An estimation of relative energy expenditure is computed using motion density from passive infrared motion sensors mounted in the environment. We introduce a new algorithm for detecting visitors in the home using motion sensor data and a set of fuzzy rules. The visitor algorithm, as well as a previous algorithm for identifying time-away-from-home (TAFH), are used to filter the logged motion sensor data. Thus, the energy expenditure estimate uses data collected only when the resident is home alone. Case studies are included from TigerPlace, an Aging in Place community, to illustrate how the relative energy expenditure estimate can be used to track health conditions over time. PMID:25266777

  5. Rapid detection of microorganisms based on active and passive modes of QCM.

    PubMed

    Farka, Zdeněk; Kovář, David; Skládal, Petr

    2014-12-23

    Label-free immunosensors are well suited for detection of microorganisms because of their fast response and reasonable sensitivity comparable to infection doses of common pathogens. Active (lever oscillator and frequency counter) and passive (impedance analyzer) modes of quartz crystal microbalance (QCM) were used and compared for rapid detection of three strains of E. coli. Different approaches for antibody immobilization were compared, the immobilization of reduced antibody using Sulfo-SMCC was most effective achieving the limit of detection (LOD) 8 × 104 CFU·mL-1 in 10 min. For the passive mode, software evaluating impedance characteristics in real-time was developed and used. Almost the same results were achieved using both active and passive modes confirming that the sensor properties are not limited by the frequency evaluation method but mainly by affinity of the antibody. Furthermore, reference measurements were done using surface plasmon resonance. Effect of condition of cells on signal was observed showing that cells ruptured by ultrasonication provided slightly higher signal changes than intact microbes.

  6. Rapid Detection of Microorganisms Based on Active and Passive Modes of QCM

    PubMed Central

    Farka, Zdeněk; Kovář, David; Skládal, Petr

    2015-01-01

    Label-free immunosensors are well suited for detection of microorganisms because of their fast response and reasonable sensitivity comparable to infection doses of common pathogens. Active (lever oscillator and frequency counter) and passive (impedance analyzer) modes of quartz crystal microbalance (QCM) were used and compared for rapid detection of three strains of E. coli. Different approaches for antibody immobilization were compared, the immobilization of reduced antibody using Sulfo‐SMCC was most effective achieving the limit of detection (LOD) 8 × 104 CFU·mL−1 in 10 min. For the passive mode, software evaluating impedance characteristics in real-time was developed and used. Almost the same results were achieved using both active and passive modes confirming that the sensor properties are not limited by the frequency evaluation method but mainly by affinity of the antibody. Furthermore, reference measurements were done using surface plasmon resonance. Effect of condition of cells on signal was observed showing that cells ruptured by ultrasonication provided slightly higher signal changes than intact microbes. PMID:25545267

  7. Combining Radiography and Passive Measurements for Radiological Threat Localization in Cargo

    NASA Astrophysics Data System (ADS)

    Miller, Erin A.; White, Timothy A.; Jarman, Kenneth D.; Kouzes, Richard T.; Kulisek, Jonathan A.; Robinson, Sean M.; Wittman, Richard A.

    2015-10-01

    Detecting shielded special nuclear material (SNM) in a cargo container is a difficult problem, since shielding reduces the amount of radiation escaping the container. Radiography provides information that is complementary to that provided by passive gamma-ray detection systems: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions that may mask a passive radiological signal. Combining these measurements has the potential to improve SNM detection, either through improved sensitivity or by providing a solution to the inverse problem to estimate source properties (strength and location). We present a data-fusion method that uses a radiograph to provide an estimate of the radiation-transport environment for gamma rays from potential sources. This approach makes quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present results for this method for a modeled test case of a cargo container passing through a plastic-scintillator-based radiation portal monitor and a transmission-radiography system. We find that a radiograph-based inversion scheme allows for localization of a low-noise source placed randomly within the test container to within 40 cm, compared to 70 cm for triangulation alone, while strength estimation accuracy is improved by a factor of six. Improvements are seen in regions of both high and low shielding, but are most pronounced in highly shielded regions. The approach proposed here combines transmission and emission data in a manner that has not been explored in the cargo-screening literature, advancing the ability to accurately describe a hidden source based on currently-available instrumentation.

  8. Operational Performance Analysis of Passive Acoustic Monitoring for Killer Whales

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzner, Shari; Fu, Tao; Ren, Huiying

    2011-09-30

    For the planned tidal turbine site in Puget Sound, WA, the main concern is to protect Southern Resident Killer Whales (SRKW) due to their Endangered Species Act status. A passive acoustic monitoring system is proposed because the whales emit vocalizations that can be detected by a passive system. The algorithm for detection is implemented in two stages. The first stage is an energy detector designed to detect candidate signals. The second stage is a spectral classifier that is designed to reduce false alarms. The evaluation presented here of the detection algorithm incorporates behavioral models of the species of interest, environmentalmore » models of noise levels and potential false alarm sources to provide a realistic characterization of expected operational performance.« less

  9. Error in measuring radon in soil gas by means of passive detectors

    USGS Publications Warehouse

    Tanner, A.B.

    1991-01-01

    Passive detection of radon isotopes depends on diffusion of radon atoms from the sites of their generation to the location of the detecting or collecting device. Because some radon decays en route to a passive detector in soil, the radon concentration measured by the detector must be less than the concentration in those soil pores where it is undiminished by diffusion to the detector cavity. The true radon concentration may be significantly underestimated in moist soils. -Author

  10. Appearance-Based Vision and the Automatic Generation of Object Recognition Programs

    DTIC Science & Technology

    1992-07-01

    q u a groued into equivalence clases with respect o visible featms; the equivalence classes me called alpecu. A recognitio smuegy is generated from...illustates th concept. pge 9 Table 1: Summary o fSnsors Samr Vertex Edge Face Active/ Passive Edge detector line, passive Shape-fzm-shading - r passive...example of the detectability computation for a liht-stripe range finder is shown zn Fqgur 2. Figure 2: Detectability of a face for a light-stripe range

  11. Laboratory evaluation of two passive alcohol sensor devices

    DOT National Transportation Integrated Search

    1988-12-01

    Passive alcohol sensing devices are designed to detect the presence of alcohol in a person's normally-expelled breath; they are "passive" in that one is not required to blow into a mouthpiece as with conventional breath test devices. The National Hig...

  12. Environmental monitoring of selected pesticides and organic chemicals in urban stormwater recycling systems using passive sampling techniques.

    PubMed

    Page, Declan; Miotliński, Konrad; Gonzalez, Dennis; Barry, Karen; Dillon, Peter; Gallen, Christie

    2014-03-01

    Water recycling via aquifers has become a valuable tool to augment urban water supplies in many countries. This study reports the first use of passive samplers for monitoring of organic micropollutants in Managed Aquifer Recharge (MAR). Five different configurations of passive samplers were deployed in a stormwater treatment wetland, groundwater monitoring wells and a recovery tank to capture a range of polar and non-polar micropollutants present in the system. The passive samplers were analysed for a suite of pesticides, polycyclic aromatic hydrocarbons (PAHs) and other chemicals. As a result, 17 pesticides and pesticide degradation products, 5 PAHs and 8 other organic chemicals including flame retardants and fragrances were detected in urban stormwater recharging Aquifer Storage and Recovery (ASR) and an Aquifer Storage Transfer and Recovery (ASTR) system. Of the pesticides detected, diuron, metolachlor and chlorpyrifos were generally detected at the highest concentrations in one or more passive samplers, whereas chlorpyrifos, diuron, metolachlor, simazine, galaxolide and triallate were detected in multiple samplers. Fluorene was the PAH detected at the highest concentration and the flame retardant Tris(1-chloro-2-propyl)phosphate was the chemical detected in the greatest abundance at all sites. The passive samplers showed different efficiencies for capture of micropollutants with the Empore disc samplers giving the most reliable results. The results indicate generally low levels of organic micropollutants in the stormwater, as the contaminants detected were present at very low ng/L levels, generally two to four orders of magnitude below the drinking water guidelines (NHMRC, 2011). The efficiency of attenuation of these organic micropollutants during MAR was difficult to determine due to variations in the source water concentrations. Comparisons were made between different samplers, to give a field-based calibration where existing lab-based calibrations were unavailable. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  13. Passive Coherent Detection and Target Location with Multiple Non-Cooperative Transmitters

    DTIC Science & Technology

    2015-06-01

    to detect, separate, classify, locate, and track sources of emissions in multi-target environments—triggered the development of passive radar...radar capitalizes on transmitters of opportunity to detect and locate sources of transmission or targets without deliberate emissions . The...equipment as all necessary hardware is currently available on most naval ships. 3 Bistatic radar geometry. Figure 1. B. HISTORY The concept of

  14. Intraoperative Mapping of Expressive Language Cortex Using Passive Real-Time Electrocorticography

    DTIC Science & Technology

    2016-08-26

    lsev ie r .com/ locate /ebcrCase ReportIntraoperative mapping of expressive language cortex using passive real-time electrocorticographyAmiLyn M...case report, we investigated the utility and practicality of passive intraoperative functional mapping of expressive language cortex using high...expressive lan- guage regions. In preparation of tumor resection, the patient underwent multiple functional language mapping procedures. We examined

  15. Passive detection of copy-move forgery in digital images: state-of-the-art.

    PubMed

    Al-Qershi, Osamah M; Khoo, Bee Ee

    2013-09-10

    Currently, digital images and videos have high importance because they have become the main carriers of information. However, the relative ease of tampering with images and videos makes their authenticity untrustful. Digital image forensics addresses the problem of the authentication of images or their origins. One main branch of image forensics is passive image forgery detection. Images could be forged using different techniques, and the most common forgery is the copy-move, in which a region of an image is duplicated and placed elsewhere in the same image. Active techniques, such as watermarking, have been proposed to solve the image authenticity problem, but those techniques have limitations because they require human intervention or specially equipped cameras. To overcome these limitations, several passive authentication methods have been proposed. In contrast to active methods, passive methods do not require any previous information about the image, and they take advantage of specific detectable changes that forgeries can bring into the image. In this paper, we describe the current state-of-the-art of passive copy-move forgery detection methods. The key current issues in developing a robust copy-move forgery detector are then identified, and the trends of tackling those issues are addressed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Stream Splitting in Support of Intrusion Detection

    DTIC Science & Technology

    2003-06-01

    increased. Every computer on the Internet has no need to see the traffic of every other computer on the Internet. Indeed if this was so, nothing would get ...distinguishes the stream splitter from other network analysis tools. B. HIGH LEVEL DESIGN To get the desired level of performance, a multi-threaded...of greater concern than added accuracy of a Bayesian model. This is a case where close is good enough . b. PassiveSensors Though similar to active

  17. DECAF - Density Estimation for Cetaceans from Passive Acoustic Fixed Sensors

    DTIC Science & Technology

    2010-01-01

    david.k.mellinger@noaa.gov Steve Martin SPAWAR Systems Center San Diego, Code 2374, 53560 Hull Street, San Diego, CA 92152-5001 Phone: (619) 553-9882...Diego, CA. Mr. Steve Martin oversaw the test cases based on data from PMRF. Martin was previously the PI on the ONR-funded project to collect...Ward, Dr. Ronald Morrissey, Ms. Nancy DiMarzio, Ms. Susan Jarvis , and Dr. Paul Baggenstoss. They used new detection algorithms developed under this

  18. Structural Damage Detection Using Virtual Passive Controllers

    NASA Technical Reports Server (NTRS)

    Lew, Jiann-Shiun; Juang, Jer-Nan

    2001-01-01

    This paper presents novel approaches for structural damage detection which uses the virtual passive controllers attached to structures, where passive controllers are energy dissipative devices and thus guarantee the closed-loop stability. The use of the identified parameters of various closed-loop systems can solve the problem that reliable identified parameters, such as natural frequencies of the open-loop system may not provide enough information for damage detection. Only a small number of sensors are required for the proposed approaches. The identified natural frequencies, which are generally much less sensitive to noise and more reliable than the identified natural frequencies, are used for damage detection. Two damage detection techniques are presented. One technique is based on the structures with direct output feedback controllers while the other technique uses the second-order dynamic feedback controllers. A least-squares technique, which is based on the sensitivity of natural frequencies to damage variables, is used for accurately identifying the damage variables.

  19. Edge modulation of electronics and transport properties of cliff-edge phosphorene nanoribbons

    NASA Astrophysics Data System (ADS)

    Guo, Caixia; Wang, Tianxing; Xia, Congxin; Liu, Yufang

    2017-12-01

    Based on the first-principles calculations, we study the electronic structures and transport properties of cliff-like edge phosphorene nanoribbons (CPNRs), considering different types of edge passivation. The band structures of bare CPNRs possess the metallic features; while hydrogen (H), fluorine (F), chlorine (Cl) and oxygen (O) atoms-passivated CPNRs are semiconductor materials, and the band gap values monotonically decrease when the ribbon width increases. Moreover, the H and F-passivated CPNRs exhibit the direct band gap characteristics, while the Cl and O-passivated cases show the features of indirect band gap. In addition, the edge passivated CPNRs are more energetically stable than bare edge case. Meanwhile, our results also show that the transport properties of the CPNRs can be obviously influenced by the different edge passivation.

  20. Workshop on the Detection, Classification, Localization and Density Estimation of Marine Mammals Using Passive Acoustics - 2015

    DTIC Science & Technology

    2015-09-30

    together the research community working on marine mammal acoustics to discuss detection, classification, localization and density estimation methods...and Density Estimation of Marine Mammals Using Passive Acoustics - 2015 John A. Hildebrand Scripps Institution of Oceanography UCSD La Jolla...dclde LONG-TERM GOALS The goal of this project was to bring together the community of researchers working on methods for detection

  1. Active and Passive Remote Sensing Data Time Series for Flood Detection and Surface Water Mapping

    NASA Astrophysics Data System (ADS)

    Bioresita, Filsa; Puissant, Anne; Stumpf, André; Malet, Jean-Philippe

    2017-04-01

    As a consequence of environmental changes surface waters are undergoing changes in time and space. A better knowledge of the spatial and temporal distribution of surface waters resources becomes essential to support sustainable policies and development activities. Especially because surface waters, are not only a vital sweet water resource, but can also pose hazards to human settlements and infrastructures through flooding. Floods are a highly frequent disaster in the world and can caused huge material losses. Detecting and mapping their spatial distribution is fundamental to ascertain damages and for relief efforts. Spaceborne Synthetic Aperture Radar (SAR) is an effective way to monitor surface waters bodies over large areas since it provides excellent temporal coverage and, all-weather day-and-night imaging capabilities. However, emergent vegetation, trees, wind or flow turbulence can increase radar back-scatter returns and pose problems for the delineation of inundated areas. In such areas, passive remote sensing data can be used to identify vegetated areas and support the interpretation of SAR data. The availability of new Earth Observation products, for example Sentinel-1 (active) and Sentinel-2 (passive) imageries, with both high spatial and temporal resolution, have the potential to facilitate flood detection and monitoring of surface waters changes which are very dynamic in space and time. In this context, the research consists of two parts. In the first part, the objective is to propose generic and reproducible methodologies for the analysis of Sentinel-1 time series data for floods detection and surface waters mapping. The processing chain comprises a series of pre-processing steps and the statistical modeling of the pixel value distribution to produce probabilistic maps for the presence of surface waters. Images pre-processing for all Sentinel-1 images comprise the reduction SAR effect like orbit errors, speckle noise, and geometric effects. A modified Split Based Approach (MSBA) is used in order to focus on surface water areas automatically and facilitate the estimation of class models for water and non-water areas. A Finite Mixture Model is employed as the underlying statistical model to produce probabilistic maps. Subsequently, bilateral filtering is applied to take into account spatial neighborhood relationships in the generation of final map. The elimination of shadows effect is performed in a post-processing step. The processing chain is tested on three case studies. The first case is a flood event in central Ireland, the second case is located in Yorkshire county / Great Britain, and the third test case covers a recent flood event in northern Italy. The tests showed that the modified SBA step and the Finite Mixture Models can be applied for the automatic surface water detection in a variety of test cases. An evaluation again Copernicus products derived from very-high resolution imagery was performed, and showed a high overall accuracy and F-measure of the obtained maps. This evaluation also showed that the use of probability maps and bilateral filtering improved the accuracy of classification results significantly. Based on this quantitative evaluation, it is concluded that the processing chain can be applied for flood mapping from Sentinel-1 data. To estimate robust statistical distributions the method requires sufficient surface waters areas in the observed zone and sufficient contrast between surface waters and other land use classes. Ongoing research addresses the fusion of Sentinel-1 and passive remote sensing data (e.g. Sentinel-2) in order to reduce the current shortcomings in the developed processing chain. In this work, fusion is performed at the feature level to better account for the difference image properties of SAR and optical sensors. Further, the processing chain is currently being optimized in terms of calculation time for a further integration as a flood mapping service on the A2S (Alsace Aval Sentinel) high-performance computing infrastructure of University of Strasbourg.

  2. Laser heterodyne detection techniques. [for atmospheric monitoring applications

    NASA Technical Reports Server (NTRS)

    Menzies, R. T.

    1976-01-01

    The principles of heterodyne radiometry are examined, taking into account thermal radiation, the Dicke microwave radiometer, photomixing in the infrared, and signal-to-noise considerations. The passive heterodyne radiometer is considered and a description is presented of heterodyne techniques in active monitoring systems. Attention is given to gas emissivities in the infrared, component requirements, experimental heterodyne detection of gases, a comparison of the passive heterodyne radiometer with the Michelson interferometer-spectrometer, airborne monitoring applications, turbulence effects on passive heterodyne radiometry, sensitivity improvements with heterodyning, atmosphere-induced degradation of bistatic system performance, pollutant detection experiments with a bistatic system, and the airborne laser absorption spectrometer. Future improvements in spectral flexibility are also discussed.

  3. The epidemiology of childhood tuberculosis in the Netherlands: still room for prevention

    PubMed Central

    2014-01-01

    Background The occurrence of tuberculosis (TB) among children has long been neglected as a public health concern. However, any child with TB is a sentinel event indicating recent transmission. Vaccination, early case finding and treatment of those latently infected with TB can prevent cases, severe morbidity and unnecessary death. Method The objective of the study was to describe the occurrence of TB events among children in the Netherlands which may be avoided through preventive measures. For this purpose we performed a trend analysis of routine Dutch TB and LTBI (surveillance data in 1993–2012 and a descriptive analysis of children with TB and with LTBI diagnosed in 2005–2012). Results Overall childhood TB incidence has declined over the last two decades from 3.6 in 1993 to 1.9 per 100,000 children in 2012. The decline was stronger among Dutch-born children compared to foreign-born children. In 2005–2012 64% of childhood TB cases were detected through active case finding. Foreign-born children with TB were less likely to be detected through active case finding, when not detected through post-entry TB screening. Childhood TB diagnosis was culture confirmed in 68% of passively detected cases and 12% of actively detected cases. Of 1,049 children with LTBI started on preventive treatment in 2005–2012, 90% completed treatment. In 37% of all childhood TB cases there was at least one ‘missed opportunity’ for prevention. Thirty nine percent of child TB patients eligible for BCG were not vaccinated. Conclusion Children with TB in the Netherlands are generally detected at an early stage and treatment completion rates are high. However, more TB cases among children can be prevented through enhancing TB case finding and screening and preventive treatment of latent TB infection among migrant children, and improving the coverage of BCG vaccination among eligible risk groups. PMID:24885314

  4. Testing Of An Ultraviolet (UV)-Transparent Polymer-Based Passive Sampler for Rapid, Ultra-Low-Cost EDC Screening Applications

    EPA Science Inventory

    A new passive sampling method with rapid low-cost spectral detection has recently been developed. The method makes use of an ultraviolet (UV)-transparent polymer which serves as both a concentrator for dissolved compounds, and an optical cell for UV spectral detection. Because ...

  5. Auditory backup alarms: distance-at-first-detection via in-situ experimentation on alarm design and hearing protection effects.

    PubMed

    Alali, Khaled; Casali, John G

    2012-01-01

    The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them more time to react to approaching vehicles. The results of this study suggest that as the attenuation of the hearing protectors increases, precautions should be considered by safety professionals. This is because, as it was the case with the Bilsom passive earmuff and E-A-R/3M Combat ArmsTM earplug-passive steady state, high attenuation minimizes the detection distance and as a result on-foot workers will have less time to react to any approaching vehicle. The main effects of the type of backup alarm signal demonstrated a statistically-significant advantage of the standard backup alarm over the broadband backup alarm on detection distance in feet. The magnitude of the improvement produced by the standard backup alarm was 221.5 feet, a very large margin. For example, with a vehicle backing at 10 mph, the 221.5 ft decrease in detection distance with the Brigade alarm equates to the vehicle arriving 15 seconds sooner at the worker from the point at which its alarm was first heard.

  6. Cardiac Magnetic Resonance-Measured Left Atrial Volume and Function and Incident Atrial Fibrillation: Results From MESA (Multi-Ethnic Study of Atherosclerosis).

    PubMed

    Habibi, Mohammadali; Samiei, Sanaz; Ambale Venkatesh, Bharath; Opdahl, Anders; Helle-Valle, Thomas M; Zareian, Mytra; Almeida, Andre L C; Choi, Eui-Young; Wu, Colin; Alonso, Alvaro; Heckbert, Susan R; Bluemke, David A; Lima, João A C

    2016-08-01

    Early detection of structural changes in left atrium (LA) before atrial fibrillation (AF) development could be helpful in identification of those at higher risk for AF. Using cardiac magnetic resonance imaging, we examined the association of LA volume and function, and incident AF in a multiethnic population free of clinical cardiovascular diseases. In a case-cohort study embedded in MESA (Multi-Ethnic Study of Atherosclerosis), baseline LA size and function assessed by cardiac magnetic resonance feature-tracking were compared between 197 participants with incident AF and 322 participants randomly selected from the whole MESA cohort. Participants were followed up for 8 years. Incident AF cases had a larger LA volume and decreased passive, active, and total LA emptying fractions and peak global LA longitudinal strain (peak LA strain) at baseline. In multivariable analysis, elevated LA maximum volume index (hazard ratio, 1.38 per SD; 95% confidence interval, 1.01-1.89) and decreased peak LA strain (hazard ratio, 0.68 per SD; 95% confidence interval, 0.48-0.96), and passive and total LA emptying fractions (hazard ratio for passive LA emptying fractions, 0.55 per SD; 95% confidence interval, 0.40-0.75 and hazard ratio for active LA emptying fractions, 0.70 per SD; 95% confidence interval, 0.52-0.95), but not active LA emptying fraction, were associated with incident AF. Elevated LA volumes and decreased passive and total LA emptying fractions were independently associated with incident AF in an asymptomatic multiethnic population. Including LA functional variables along with other risk factors of AF may help to better risk stratify individuals at risk of AF development. © 2016 American Heart Association, Inc.

  7. Passive infrared ice detection for helicopter applications

    NASA Technical Reports Server (NTRS)

    Dershowitz, Adam L.; Hansman, R. John, Jr.

    1990-01-01

    A technique is proposed to remotely detect rotor icing on helicopters by using passive IR thermometry to detect the warming caused by latent heat release as supercooled water freezes. During icing, the ice accretion region will be warmer than the uniced trailing edge, resulting in a characteristic chordwise temperature profile. Preliminary tests were conducted on a static model in the NASA Icing Research Tunnel for a variety of wet (glaze) and dry (rime) ice conditions. The chordwise temperature profiles were confirmed by observation with an IR thermal video system and thermocouple observations. The IR observations were consistent with predictions of the LEWICE ice accretion code, which was used to extrapolate the observations to rotor icing conditions. Based on the static observations, the passive IR ice detection technique appears promising; however, further testing or rotating blades is required.

  8. Combining Radiography and Passive Measurements for Radiological Threat Localization in Cargo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Erin A.; White, Timothy A.; Jarman, Kenneth D.

    Detecting shielded special nuclear material (SNM) in a cargo container is a difficult problem, since shielding reduces the amount of radiation escaping the container. Radiography provides information that is complementary to that provided by passive gamma-ray detection systems: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions that may mask a passive radiological signal. Combining these measurements has the potential to improve SNM detection, either through improved sensitivity or by providing a solution to the inverse problem to estimate source properties (strength and location). We present a data-fusion method that uses a radiograph to provide anmore » estimate of the radiation-transport environment for gamma rays from potential sources. This approach makes quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present results for this method for a modeled test case of a cargo container passing through a plastic-scintillator-based radiation portal monitor and a transmission-radiography system. We find that a radiograph-based inversion scheme allows for localization of a low-noise source placed randomly within the test container to within 40 cm, compared to 70 cm for triangulation alone, while strength estimation accuracy is improved by a factor of six. Improvements are seen in regions of both high and low shielding, but are most pronounced in highly shielded regions. The approach proposed here combines transmission and emission data in a manner that has not been explored in the cargo-screening literature, advancing the ability to accurately describe a hidden source based on currently-available instrumentation.« less

  9. Cloud Coverage and Height Distribution from the GLAS Polar Orbiting Lidar: Comparison to Passive Cloud Retrievals

    NASA Technical Reports Server (NTRS)

    Spinhime, J. D.; Palm, S. P.; Hlavka, D. L.; Hart, W. D.; Mahesh, A.

    2004-01-01

    The Geoscience Laser Altimeter System (GLAS) began full on orbit operations in September 2003. A main application of the two-wavelength GLAS lidar is highly accurate detection and profiling of global cloud cover. Initial analysis indicates that cloud and aerosol layers are consistently detected on a global basis to cross-sections down to 10(exp -6) per meter. Images of the lidar data dramatically and accurately show the vertical structure of cloud and aerosol to the limit of signal attenuation. The GLAS lidar has made the most accurate measurement of global cloud coverage and height to date. In addition to the calibrated lidar signal, GLAS data products include multi level boundaries and optical depth of all transmissive layers. Processing includes a multi-variable separation of cloud and aerosol layers. An initial application of the data results is to compare monthly cloud means from several months of GLAS observations in 2003 to existing cloud climatologies from other satellite measurement. In some cases direct comparison to passive cloud retrievals is possible. A limitation of the lidar measurements is nadir only sampling. However monthly means exhibit reasonably good global statistics and coverage results, at other than polar regions, compare well with other measurements but show significant differences in height distribution. For polar regions where passive cloud retrievals are problematic and where orbit track density is greatest, the GLAS results are particularly an advance in cloud cover information. Direct comparison to MODIS retrievals show a better than 90% agreement in cloud detection for daytime, but less than 60% at night. Height retrievals are in much less agreement. GLAS is a part of the NASA EOS project and data products are thus openly available to the science community (see http://glo.gsfc.nasa.gov).

  10. L-Band RFI in Japan

    NASA Technical Reports Server (NTRS)

    Soldo, Yan; de Matthaeis, Paolo; Le Vine, David M.

    2016-01-01

    In recent years, three instruments have been launched into orbit with the aim of producing global maps of sea surface salinity and soil moisture using the 1400-1427 MHz band: SMOS, Aquarius and SMAP. Although this frequency band is allocated to passive measurements only, RFI (Radio-Frequency Interference) is present in the data of all three missions. On a global scale, the three sensors have observed approximately the same distribution of RFI. Japan is an important exception that has implications for the design of RFI detection algorithms. RFI in Japan is caused by a large number of emitters belonging to the same system (TV receivers) and for this reason some traditional RFI detection strategies detect little to no RFI over Japan. The study of this case has led to an improvement of the approach to detect RFI in Aquarius data.

  11. Passive detection of subpixel obstacles for flight safety

    NASA Astrophysics Data System (ADS)

    Nixon, Matthew D.; Loveland, Rohan C.

    2001-12-01

    Military aircraft fly below 100 ft. above ground level in support of their missions. These aircraft include fixed and rotary wing and may be manned or unmanned. Flying at these low altitudes presents a safety hazard to the aircrew and aircraft, due to the occurrences of obstacles within the aircraft's flight path. The pilot must rely on eyesight and in some cases, infrared sensors to see obstacles. Many conditions can exacerbate visibility creating a situation in which obstacles are essentially invisible, creating a safety hazard, even to an alerted aircrew. Numerous catastrophic accidents have occurred in which aircraft have collided with undetected obstacles. Accidents of this type continue to be a problem for low flying military and commercial aircraft. Unmanned Aerial Vehicles (UAVs) have the same problem, whether operating autonomously or under control of a ground operator. Boeing-SVS has designed a passive, small, low- cost (under $100k) gimbaled, infrared imaging based system with advanced obstacle detection algorithms. Obstacles are detected in the infrared band, and linear features are analyzed by innovative cellular automata based software. These algorithms perform detection and location of sub-pixel linear features. The detection of the obstacles is performed on a frame by frame basis, in real time. Processed images are presented to the aircrew on their display as color enhanced features. The system has been designed such that the detected obstacles are displayed to the aircrew in sufficient time to react and maneuver the aircraft to safety. A patent for this system is on file with the US patent office, and all material herein should be treated accordingly.

  12. High rates of detection of Clade 2.3.4.4 Highly Pathogenic Avian Influenza H5 viruses in wild birds in the Pacific Northwest during the winter of 2014-2015

    USGS Publications Warehouse

    Ip, Hon S.; Dusek, Robert J.; Bodenstein, Barbara L.; Kim Torchetti, Mia; DeBruyn, Paul; Mansfield, Kristin G.; DeLiberto, Thomas; Sleeman, Jonathan M.

    2016-01-01

    In 2014, Clade 2.3.4.4 H5N8 highly pathogenic avian influenza (HPAI) viruses spread across the Republic of Korea and ultimately were reported in China, Japan, Russia and Europe. Mortality associated with a reassortant HPAI H5N2 virus was detected in poultry farms in Western Canada at the end of November. The same strain (with identical genetic structure) was then detected in free-living wild birds that had died prior to December 8 of unrelated causes in Whatcom County, Washington, USA in an area contiguous with the index Canadian location. A gyrfalcon (Falco rusticolus) that had hunted and fed on an American wigeon (Anas americana) on December 6 in the same area and died two days later, tested positive for the Eurasian origin HPAI H5N8. Subsequently, an Active Surveillance Program using hunter-harvest waterfowl in Washington and Oregon detected ten HPAI H5 viruses, of three different subtypes (four H5N2, three H5N8 and three H5N1) with 4 segments in common (HA, PB2, NP and MA). In addition, a mortality-based Passive Surveillance Program detected 18 HPAI (14 H5N2 and four H5N8) cases from Idaho, Kansas, Oregon, Minnesota, Montana, Washington and Wisconsin. Comparatively, mortality-based passive surveillance appears to be detecting these HPAI infections at a higher rate than active surveillance during the period following initial introduction into the US.

  13. High Rates of Detection of Clade 2.3.4.4 Highly Pathogenic Avian Influenza H5 Viruses in Wild Birds in the Pacific Northwest During the Winter of 2014-15.

    PubMed

    Ip, Hon S; Dusek, Robert J; Bodenstein, Barbara; Torchetti, Mia Kim; DeBruyn, Paul; Mansfield, Kristin G; DeLiberto, Thomas; Sleeman, Jonathan M

    2016-05-01

    In 2014, clade 2.3.4.4 H5N8 highly pathogenic avian influenza (HPAI) viruses spread across the Republic of Korea and ultimately were reported in China, Japan, Russia, and Europe. Mortality associated with a reassortant HPAI H5N2 virus was detected in poultry farms in western Canada at the end of November. The same strain (with identical genetic structure) was then detected in free-living wild birds that had died prior to December 8, 2014, of unrelated causes in Whatcom County, Washington, U. S. A., in an area contiguous with the index Canadian location. A gyrfalcon (Falco rusticolus) that had hunted and fed on an American wigeon (Anas americana) on December 6, 2014, in the same area, and died 2 days later, tested positive for the Eurasian-origin HPAI H5N8. Subsequently, an active surveillance program using hunter-harvested waterfowl in Washington and Oregon detected 10 HPAI H5 viruses, of three different subtypes (four H5N2, three H5N8, and three H5N1) with four segments in common (HA, PB2, NP, and MA). In addition, a mortality-based passive surveillance program detected 18 HPAI (14 H5N2 and four H5N8) cases from Idaho, Kansas, Oregon, Minnesota, Montana, Washington, and Wisconsin. Comparatively, mortality-based passive surveillance appears to have detected these HPAI infections at a higher rate than active surveillance during the period following initial introduction into the United States.

  14. Nicotine cut-off value in human hair as a tool to distinguish active from passive smokers: A cross-sectional study in Japanese men.

    PubMed

    Tsuji, Masayoshi; Kanda, Hideyuki; Hayakawa, Takehito; Mori, Yayoi; Ito, Teruna; Hidaka, Tomoo; Kakamu, Takeyasu; Kumagai, Tomohiro; Osaki, Yoneatsu; Kawazoe, Miki; Sato, Sei; Fukushima, Tetsuhito

    2017-07-19

    Nicotine concentration in hair is a useful marker of tobacco exposure. Detection of nicotine in the hair of non-smokers indicates passive smoking. Accurate measurement of nicotine among active and passive smokers can help in smoking cessation programs or programs designed to prevent secondhand smoke exposure. To establish, using high-performance liquid chromatography-ultraviolet detection (HPLC/UV), a hair nicotine cut-off value to distinguish active from passive smokers. Hair samples were collected from randomly chosen Japanese men (n= 192) between 2009 and 2011. Nicotine and cotinine levels in hair were measured using HPLC/UV with column-switching. T-tests and chi-square tests were performed to compare active and passive smokers, while receiver operating characteristic curves were used to evaluate the effectiveness of the cut-off value. There were 69 active smokers and 123 passive smokers. The nicotine and cotinine concentrations in hair were significantly higher in active than in passive smokers (p< 0.01). The area under the curve for nicotine was 0.92. A hair nicotine cut-off value of 5.68 ng/mg, with a sensitivity of 94.2% and specificity of 87.0%, was identified as the optimal cut-off value for separating active from passive smokers. Nicotine and cotinine concentrations in hair clearly distinguished active from passive smokers.

  15. Multi-sensor millimeter-wave system for hidden objects detection by non-collaborative screening

    NASA Astrophysics Data System (ADS)

    Zouaoui, Rhalem; Czarny, Romain; Diaz, Frédéric; Khy, Antoine; Lamarque, Thierry

    2011-05-01

    In this work, we present the development of a multi-sensor system for the detection of objects concealed under clothes using passive and active millimeter-wave (mmW) technologies. This study concerns both the optimization of a commercial passive mmW imager at 94 GHz using a phase mask and the development of an active mmW detector at 77 GHz based on synthetic aperture radar (SAR). A first wide-field inspection is done by the passive imager while the person is walking. If a suspicious area is detected, the active imager is switched-on and focused on this area in order to obtain more accurate data (shape of the object, nature of the material ...).

  16. Design of short-range terahertz wave passive detecting system

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Lou, Guowei; Zhu, Li; Qian, Songsong; Li, Ting

    2016-09-01

    Based on the study of radiation and transmission characteristics on THz waveband, a short-range passive detecting system is designed. The scheme originated from microwave passive detecting system. A prototype was developed following the design of key components including antennas and a harmonic mixer. The system operated at 0.36 THz. A dual-beam Cassegrain antenna was adopted for receiving signals which radiated by object and background. Local oscillator signal was generated by frequency multiplication. Harmonic mixing is adopted for reducing local oscillator signal frequency required by half. Superheterodyne technology is employed for signal acquisition. The system implemented easily. Tests and measurements were taken, which showed that the scheme was feasible and the performance of the prototype system met the design requirements.

  17. A Wireless Fully Passive Neural Recording Device for Unobtrusive Neuropotential Monitoring.

    PubMed

    Kiourti, Asimina; Lee, Cedric W L; Chae, Junseok; Volakis, John L

    2016-01-01

    We propose a novel wireless fully passive neural recording device for unobtrusive neuropotential monitoring. Previous work demonstrated the feasibility of monitoring emulated brain signals in a wireless fully passive manner. In this paper, we propose a novel realistic recorder that is significantly smaller and much more sensitive. The proposed recorder utilizes a highly efficient microwave backscattering method and operates without any formal power supply or regulating elements. Also, no intracranial wires or cables are required. In-vitro testing is performed inside a four-layer head phantom (skin, bone, gray matter, and white matter). Compared to our former implementation, the neural recorder proposed in this study has the following improved features: 1) 59% smaller footprint, 2) up to 20-dB improvement in neuropotential detection sensitivity, and 3) encapsulation in biocompatible polymer. For the first time, temporal emulated neuropotentials as low as 63 μVpp can be detected in a wireless fully passive manner. Remarkably, the high-sensitivity achieved in this study implies reading of most neural signals generated by the human brain. The proposed recorder brings forward transformational possibilities in wireless fully passive neural detection for a very wide range of applications (e.g., epilepsy, Alzheimer's, mental disorders, etc.).

  18. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    NASA Astrophysics Data System (ADS)

    Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter

    2017-11-01

    Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  19. Signatures of Hydrometeor Species from Airborne Passive Microwave Data for Frequencies 10-183 GHz

    NASA Technical Reports Server (NTRS)

    Cecil, Daniel J.; Leppert, Kenneth, II

    2014-01-01

    There are 2 basic precipitation retrieval methods using passive microwave measurements: (1) Emission-based: Based on the tendency of liquid precipitation to cause an increase in brightness temperature (BT) primarily at frequencies below 22 GHz over a radiometrically cold background, often an ocean background (e.g., Spencer et al. 1989; Adler et al. 1991; McGaughey et al. 1996); and (2) Scattering-based: Based on the tendency of precipitation-sized ice to scatter upwelling radiation, thereby reducing the measured BT over a relatively warmer (usually land) background at frequencies generally 37 GHz (e.g., Spencer et al. 1989; Smith et al. 1992; Ferraro and Marks 1995). Passive microwave measurements have also been used to detect intense convection (e.g., Spencer and Santek 1985) and for the detection of hail (e.g., Cecil 2009; Cecil and Blankenship 2012; Ferraro et al. 2014). The Global Precipitation Measurement (GPM) mission expands upon the successful Tropical Rainfall Measurement Mission program to provide global rainfall and snowfall observations every 3 hours (Hou et al. 2014). One of the instruments on board the GPM Core Observatory is the GPM Microwave Imager (GMI) which is a conically-scanning microwave radiometer with 13 channels ranging from 10-183 GHz. Goal of this study: Determine the signatures of various hydrometeor species in terms of BTs measured at frequencies used by GMI by using data collected on 3 case days (all having intense/severe convection) during the Mid-latitude Continental Convective Clouds Experiment conducted over Oklahoma in 2011.

  20. Inertial navigation sensor integrated obstacle detection system

    NASA Technical Reports Server (NTRS)

    Bhanu, Bir (Inventor); Roberts, Barry A. (Inventor)

    1992-01-01

    A system that incorporates inertial sensor information into optical flow computations to detect obstacles and to provide alternative navigational paths free from obstacles. The system is a maximally passive obstacle detection system that makes selective use of an active sensor. The active detection typically utilizes a laser. Passive sensor suite includes binocular stereo, motion stereo and variable fields-of-view. Optical flow computations involve extraction, derotation and matching of interest points from sequential frames of imagery, for range interpolation of the sensed scene, which in turn provides obstacle information for purposes of safe navigation.

  1. Possible Statistics of Two Coupled Random Fields: Application to Passive Scalar

    NASA Technical Reports Server (NTRS)

    Dubrulle, B.; He, Guo-Wei; Bushnell, Dennis M. (Technical Monitor)

    2000-01-01

    We use the relativity postulate of scale invariance to derive the similarity transformations between two coupled scale-invariant random elds at different scales. We nd the equations leading to the scaling exponents. This formulation is applied to the case of passive scalars advected i) by a random Gaussian velocity field; and ii) by a turbulent velocity field. In the Gaussian case, we show that the passive scalar increments follow a log-Levy distribution generalizing Kraichnan's solution and, in an appropriate limit, a log-normal distribution. In the turbulent case, we show that when the velocity increments follow a log-Poisson statistics, the passive scalar increments follow a statistics close to log-Poisson. This result explains the experimental observations of Ruiz et al. about the temperature increments.

  2. Neuronal correlates of a virtual-reality-based passive sensory P300 network.

    PubMed

    Chen, Chun-Chuan; Syue, Kai-Syun; Li, Kai-Chiun; Yeh, Shih-Ching

    2014-01-01

    P300, a positive event-related potential (ERP) evoked at around 300 ms after stimulus, can be elicited using an active or passive oddball paradigm. Active P300 requires a person's intentional response, whereas passive P300 does not require an intentional response. Passive P300 has been used in incommunicative patients for consciousness detection and brain computer interface. Active and passive P300 differ in amplitude, but not in latency or scalp distribution. However, no study has addressed the mechanism underlying the production of passive P300. In particular, it remains unclear whether the passive P300 shares an identical active P300 generating network architecture when no response is required. This study aims to explore the hierarchical network of passive sensory P300 production using dynamic causal modelling (DCM) for ERP and a novel virtual reality (VR)-based passive oddball paradigm. Moreover, we investigated the causal relationship of this passive P300 network and the changes in connection strength to address the possible functional roles. A classical ERP analysis was performed to verify that the proposed VR-based game can reliably elicit passive P300. The DCM results suggested that the passive and active P300 share the same parietal-frontal neural network for attentional control and, underlying the passive network, the feed-forward modulation is stronger than the feed-back one. The functional role of this forward modulation may indicate the delivery of sensory information, automatic detection of differences, and stimulus-driven attentional processes involved in performing this passive task. To our best knowledge, this is the first study to address the passive P300 network. The results of this study may provide a reference for future clinical studies on addressing the network alternations under pathological states of incommunicative patients. However, caution is required when comparing patients' analytic results with this study. For example, the task presented here is not applicable to incommunicative patients.

  3. Neuronal Correlates of a Virtual-Reality-Based Passive Sensory P300 Network

    PubMed Central

    Chen, Chun-Chuan; Syue, Kai-Syun; Li, Kai-Chiun; Yeh, Shih-Ching

    2014-01-01

    P300, a positive event-related potential (ERP) evoked at around 300 ms after stimulus, can be elicited using an active or passive oddball paradigm. Active P300 requires a person’s intentional response, whereas passive P300 does not require an intentional response. Passive P300 has been used in incommunicative patients for consciousness detection and brain computer interface. Active and passive P300 differ in amplitude, but not in latency or scalp distribution. However, no study has addressed the mechanism underlying the production of passive P300. In particular, it remains unclear whether the passive P300 shares an identical active P300 generating network architecture when no response is required. This study aims to explore the hierarchical network of passive sensory P300 production using dynamic causal modelling (DCM) for ERP and a novel virtual reality (VR)-based passive oddball paradigm. Moreover, we investigated the causal relationship of this passive P300 network and the changes in connection strength to address the possible functional roles. A classical ERP analysis was performed to verify that the proposed VR-based game can reliably elicit passive P300. The DCM results suggested that the passive and active P300 share the same parietal-frontal neural network for attentional control and, underlying the passive network, the feed-forward modulation is stronger than the feed-back one. The functional role of this forward modulation may indicate the delivery of sensory information, automatic detection of differences, and stimulus-driven attentional processes involved in performing this passive task. To our best knowledge, this is the first study to address the passive P300 network. The results of this study may provide a reference for future clinical studies on addressing the network alternations under pathological states of incommunicative patients. However, caution is required when comparing patients’ analytic results with this study. For example, the task presented here is not applicable to incommunicative patients. PMID:25401520

  4. Successful passive and active immunization of cynomolgus monkeys against hepatitis E.

    PubMed Central

    Tsarev, S A; Tsareva, T S; Emerson, S U; Govindarajan, S; Shapiro, M; Gerin, J L; Purcell, R H

    1994-01-01

    Virtually full protection against hepatitis E and partial or complete protection against infection with hepatitis E virus (HEV) were achieved in passively or actively immunized cynomolgus monkeys. Hepatitis, viremia, and shedding of the virus in feces were detected in all nonimmunized animals that were challenged with HEV. HEV titers detected by reverse transcriptase PCR were higher in feces than in serum of nonimmunized animals. Anti-HEV antibody titers at the time of challenge ranged between 1:40 and 1:200 in animals passively immunized with convalescent plasma from a cynomolgus monkey previously infected with HEV and between 1:100 and 1:10,000 in animals actively immunized with a recombinant 55-kDa open reading frame 2 protein. The estimated 50% protective titer of passively acquired anti-HEV antibodies was 1:40. Although only one of four passively immunized animals showed histopathologic evidence of hepatitis, all four were infected after challenge; however, the titers of HEV in serum and feces were lower in the passively immunized animals than in the nonimmunized group. The actively immunized animals developed neither hepatitis nor viremia when challenged with HEV and virus was either not detected or was present in low titer in feces. The protective response was a function of the ELISA anti-HEV antibody titer at the time of challenge and the immunization schedule. PMID:7937861

  5. Passive Smoking and Breast Cancer Risk among Non-Smoking Women: A Case-Control Study in China.

    PubMed

    Li, Bin; Wang, Lian; Lu, Min-Shan; Mo, Xiong-Fei; Lin, Fang-Yu; Ho, Suzanne C; Zhang, Cai-Xia

    2015-01-01

    The role of passive smoking on breast cancer risk was unclear. This study aimed to evaluate the association between passive smoking and breast cancer risk among Chinese women. A hospital-based case-control study, including 877 breast cancer cases and 890 controls, frequency-matched by age and residence, was conducted. A structured questionnaire was used to collect information on passive smoking history through face-to-face interview by trained interviewers. Unconditional logistic regression models were used to estimate the association between passive smoking and breast cancer risk. A positive association between any passive smoking exposure and breast cancer risk was observed. Compared with women who were never exposed to passive smoking, women who were ever exposed had a higher breast cancer risk, with the adjusted odds ratio (OR) and 95% confidence interval (CI) of 1.35 (1.11-1.65). Similar result was found on home passive smoking exposure and breast cancer risk, but not on workplace passive smoking exposure. Women who were ever exposed to tobacco smoke at home had a higher risk of breast cancer compared with never exposed women, with the adjusted OR (95% CI) of 1.30 (1.05-1.61). Home passive smoking exposure showed significant dose-response relationships with breast cancer risk in smoker-years, cigarettes/day and total pack-years (Ptrend=0.003, 0.006 and 0.009, respectively). An increased total smoker-years of any passive exposure significantly elevated the risk of breast cancer (Ptrend<0.001). Positive associations and dose-response relationships were found among postmenopausal women and all subtypes of estrogen receptor (ER) and progesterone receptor (PR) status of breast cancer. Passive smoking was associated with an increased risk of breast cancer among non-smoking Chinese women. A stronger positive association with breast cancer risk was seen mainly among postmenopausal women.

  6. Passive Smoking and Breast Cancer Risk among Non-Smoking Women: A Case-Control Study in China

    PubMed Central

    Li, Bin; Wang, Lian; Lu, Min-Shan; Mo, Xiong-Fei; Lin, Fang-Yu; Ho, Suzanne C.; Zhang, Cai-Xia

    2015-01-01

    Background The role of passive smoking on breast cancer risk was unclear. This study aimed to evaluate the association between passive smoking and breast cancer risk among Chinese women. Methods/Principal Findings A hospital-based case-control study, including 877 breast cancer cases and 890 controls, frequency-matched by age and residence, was conducted. A structured questionnaire was used to collect information on passive smoking history through face-to-face interview by trained interviewers. Unconditional logistic regression models were used to estimate the association between passive smoking and breast cancer risk. A positive association between any passive smoking exposure and breast cancer risk was observed. Compared with women who were never exposed to passive smoking, women who were ever exposed had a higher breast cancer risk, with the adjusted odds ratio (OR) and 95% confidence interval (CI) of 1.35 (1.11-1.65). Similar result was found on home passive smoking exposure and breast cancer risk, but not on workplace passive smoking exposure. Women who were ever exposed to tobacco smoke at home had a higher risk of breast cancer compared with never exposed women, with the adjusted OR (95% CI) of 1.30 (1.05-1.61). Home passive smoking exposure showed significant dose-response relationships with breast cancer risk in smoker-years, cigarettes/day and total pack-years (P trend=0.003, 0.006 and 0.009, respectively). An increased total smoker-years of any passive exposure significantly elevated the risk of breast cancer (P trend<0.001). Positive associations and dose-response relationships were found among postmenopausal women and all subtypes of estrogen receptor (ER) and progesterone receptor (PR) status of breast cancer. Conclusions Passive smoking was associated with an increased risk of breast cancer among non-smoking Chinese women. A stronger positive association with breast cancer risk was seen mainly among postmenopausal women. PMID:25915759

  7. Vestibular-somatosensory interactions: effects of passive whole-body rotation on somatosensory detection.

    PubMed

    Ferrè, Elisa Raffaella; Kaliuzhna, Mariia; Herbelin, Bruno; Haggard, Patrick; Blanke, Olaf

    2014-01-01

    Vestibular signals are strongly integrated with information from several other sensory modalities. For example, vestibular stimulation was reported to improve tactile detection. However, this improvement could reflect either a multimodal interaction or an indirect interaction driven by vestibular effects on spatial attention and orienting. Here we investigate whether natural vestibular activation induced by passive whole-body rotation influences tactile detection. In particular, we assessed the ability to detect faint tactile stimuli to the fingertips of the left and right hand during spatially congruent or incongruent rotations. We found that passive whole-body rotations significantly enhanced sensitivity to faint shocks, without affecting response bias. Critically, this enhancement of somatosensory sensitivity did not depend on the spatial congruency between the direction of rotation and the hand stimulated. Thus, our results support a multimodal interaction, likely in brain areas receiving both vestibular and somatosensory signals.

  8. Mobile Pit verification system design based on passive special nuclear material verification in weapons storage facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul, J. N.; Chin, M. R.; Sjoden, G. E.

    2013-07-01

    A mobile 'drive by' passive radiation detection system to be applied in special nuclear materials (SNM) storage facilities for validation and compliance purposes has been designed through the use of computational modeling and new radiation detection methods. This project was the result of work over a 1 year period to create optimal design specifications to include creation of 3D models using both Monte Carlo and deterministic codes to characterize the gamma and neutron leakage out each surface of SNM-bearing canisters. Results were compared and agreement was demonstrated between both models. Container leakages were then used to determine the expected reactionmore » rates using transport theory in the detectors when placed at varying distances from the can. A 'typical' background signature was incorporated to determine the minimum signatures versus the probability of detection to evaluate moving source protocols with collimation. This established the criteria for verification of source presence and time gating at a given vehicle speed. New methods for the passive detection of SNM were employed and shown to give reliable identification of age and material for highly enriched uranium (HEU) and weapons grade plutonium (WGPu). The finalized 'Mobile Pit Verification System' (MPVS) design demonstrated that a 'drive-by' detection system, collimated and operating at nominally 2 mph, is capable of rapidly verifying each and every weapon pit stored in regularly spaced, shelved storage containers, using completely passive gamma and neutron signatures for HEU and WGPu. This system is ready for real evaluation to demonstrate passive total material accountability in storage facilities. (authors)« less

  9. Experimental investigation of passive infrared ice detection for helicopter applications

    NASA Technical Reports Server (NTRS)

    Dershowitz, Adam; Hansman, R. John, Jr.

    1991-01-01

    A technique is proposed to remotely detect rotor icing on helicopters. Using passive infrared (IR) thermometry it is possible to detect the warming caused by latent heat released as supercooled water freezes. During icing, the ice accretion region on the blade leading edge will be warmer than the uniced trailing edge resulting in a chordwise temperature profile characteristic of icing. Preliminary tests were conducted on a static model in the NASA Icing Research Tunnel for a variety of wet (glaze) and dry (rime) ice conditions. The characteristic chordwise temperature profiles were observed with an IR thermal video system and confirmed with thermocouple measurements. A prototype detector system was built consisting of a single point IR pyrometer, and experiments were run on a small scale rotor model. Again the characteristic chordwise temperature profiles were observed during icing, and the IR system was able to remotely detect icing. Based on the static and subscale rotor tests the passive IR technique is promising for rotor ice detection.

  10. Experimental investigation of passive infrared ice detection for helicopter applications

    NASA Technical Reports Server (NTRS)

    Dershowitz, Adam; Hansman, R. John, Jr.

    1991-01-01

    A technique is proposed to remotely detect rotor icing on helicopters. Using passive infrared (IR) thermometry, it is possible to detect the warming caused by latent heat released as supercooled water freezes. During icing, the ice accretion region on the blade leading edge will be warmer than the uniced trailing edge, resulting in a chordwise temperature profile characteristic of icing. Preliminary tests were conducted on a static model in the NASA Icing Research Tunnel for a variety of wet (glaze) and dry (rime) ice conditions. The characteristic chordwise temperature profiles were observed with an IR thermal video system and confirmed with thermocouple measurements. A prototype detector system was built consisting of a single point IR pyrometer. Experiments were run on a small scale rotor model. Again, the characteristic chordwise temperature profiles were observed during icing, and the IR system was able to remotely detect icing. Based on the static and subscale rotor tests, the passive IR technique is promising for rotor ice detection.

  11. Study to investigate and evaluate means of optimizing the Ku-band combined radar/communication functions for the space shuttle

    NASA Technical Reports Server (NTRS)

    Weber, C. L.; Udalov, S.; Alem, W.

    1977-01-01

    The performance of the space shuttle orbiter's Ku-Band integrated radar and communications equipment is analyzed for the radar mode of operation. The block diagram of the rendezvous radar subsystem is described. Power budgets for passive target detection are calculated, based on the estimated values of system losses. Requirements for processing of radar signals in the search and track modes are examined. Time multiplexed, single-channel, angle tracking of passive scintillating targets is analyzed. Radar performance in the presence of main lobe ground clutter is considered and candidate techniques for clutter suppression are discussed. Principal system parameter drivers are examined for the case of stationkeeping at ranges comparable to target dimension. Candidate ranging waveforms for short range operation are analyzed and compared. The logarithmic error discriminant utilized for range, range rate and angle tracking is formulated and applied to the quantitative analysis of radar subsystem tracking loops.

  12. pySeismicDQA: open source post experiment data quality assessment and processing

    NASA Astrophysics Data System (ADS)

    Polkowski, Marcin

    2017-04-01

    Seismic Data Quality Assessment is python based, open source set of tools dedicated for data processing after passive seismic experiments. Primary goal of this toolset is unification of data types and formats from different dataloggers necessary for further processing. This process requires additional data checks for errors, equipment malfunction, data format errors, abnormal noise levels, etc. In all such cases user needs to decide (manually or by automatic threshold) if data is removed from output dataset. Additionally, output dataset can be visualized in form of website with data availability charts and waveform visualization with earthquake catalog (external). Data processing can be extended with simple STA/LTA event detection. pySeismicDQA is designed and tested for two passive seismic experiments in central Europe: PASSEQ 2006-2008 and "13 BB Star" (2013-2016). National Science Centre Poland provided financial support for this work via NCN grant DEC-2011/02/A/ST10/00284.

  13. Visible absorbance spectra: A basis for in situ and passive remote sensing of phytoplankton concentration and community composition

    NASA Technical Reports Server (NTRS)

    Farmer, F. H.; Jarrett, O., Jr.; Brown, C. A., Jr.

    1983-01-01

    The concentration and composition of phytoplankton populations are measured by an optical method which can be used either in situ or remotely. This method is based upon the in vivo light absorption characteristics of phytoplankton. To provide a data base for testing assumptions relative to the proposed method, visible absorbance spectra of pure cultures of 20 marine phytoplankton were obtained under laboratory conditions. Descriptive and analytical statistics were computed for the absorbance spectra and were used to make comparisons between members of major taxonomic groups and between groups. Spectral variation between the members of the major taxonomic groups was observed to be considerably less than the spectral variation between these groups. In several cases the differences between the mean absorbance spectra of major taxonomic groups are significant enough to be detected with passive remote sensing techniques.

  14. Nancy B and Nancy F.

    PubMed

    Burkholder, L

    2001-01-01

    In this article I provide a virtuous slippery slope argument which shows that there is no morally significant difference between passive and active euthanasia. At the top of the slope is an example of passive euthanasia; at the bottom, an example of active euthanasia. For each pair of cases down the slope there is nothing that sensibly makes a morally significant difference between the pair of cases. Thus, there is no morally significant difference between passive euthanasia and active euthanasia.

  15. Advanced Demonstration of Motion Correction for Ship-to-Ship Passive Inspections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ziock, Klaus-Peter; Boehnen, Chris Bensing; Ernst, Joseph

    2013-09-30

    Passive radiation detection is a key tool for detecting illicit nuclear materials. In maritime applications it is most effective against small vessels where attenuation is of less concern. Passive imaging provides: discrimination between localized (threat) and distributed (non-threat) sources, removal of background fluctuations due to nearby shorelines and structures, source localization to an individual craft in crowded waters, and background subtracted spectra. Unfortunately, imaging methods cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing sensitivity. This is particularly true for the smaller water craft where passive inspections aremore » most valuable. In this project we performed tests and improved the performance of an instrument (developed earlier under, “Motion Correction for Ship-to-Ship Passive Inspections”) that uses automated tracking of a target vessel in visible-light images to generate a 3D radiation map of the target vessel from data obtained using a gamma-ray imager.« less

  16. Applications of matched field processing to damage detection in composite wind turbine blades

    NASA Astrophysics Data System (ADS)

    Tippmann, Jeffery D.; Lanza di Scalea, Francesco

    2015-03-01

    There are many structures serving vital infrastructure, energy, and national security purposes. Inspecting the components and areas of the structure most prone to failure during maintenance operations by using non- destructive evaluation methods has been essential in avoiding costly, but preventable, catastrophic failures. In many cases, the inspections are performed by introducing acoustic, ultrasonic, or even thermographic waves into the structure and then evaluating the response. Sometimes the structure, or a component, is not accessible for active inspection methods. Because of this, there is a growing interest to use passive methods, such as using ambient noise, or sources of opportunity, to produce a passive impulse response function similar to the active approach. Several matched field processing techniques most notably used in oceanography and seismology applications are examined in more detail. While sparse array imaging in structures has been studied for years, all methods studied previously have used an active interrogation approach. Here, structural damage detection is studied by use of the reconstructed impulse response functions in ambient noise within sparse array imaging techniques, such as matched-field processing. This has been studied in experiments on a 9-m wind turbine blade.

  17. Global Measurements of Optically Thin Ice Clouds Using CALIOP

    NASA Technical Reports Server (NTRS)

    Ryan, R.; Avery, M.; Tackett, J.

    2017-01-01

    Optically thin ice clouds have been shown to have a net warming effect on the globe but, because passive instruments are not sensitive to optically thin clouds, the occurrence frequency of this class of clouds is greatly underestimated in historical passive sensor cloud climatology. One major strength of CALIOP (Cloud-Aerosol Lidar with Orthogonal Polarization), onboard the CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations) spacecraft, is its ability to detect these thin clouds, thus filling an important missing piece in the historical data record. This poster examines the full mission of CALIPSO Level 2 data, focusing on those CALIOP retrievals identified as thin ice clouds according to the definition shown to the right. Using this definition, thin ice clouds are identified and counted globally and vertically for each season. By examining the spatial and seasonal distributions of these thin clouds we hope to gain a better understanding these thin ice clouds and how their global distribution has changed over the mission. This poster showcases when and where CALIOP detects thin ice clouds and examines a case study of the eastern pacific and the effects seen from the El Nino-Southern Oscillation (ENSO).

  18. Method and means of passive detection of leaks in buried pipes

    DOEpatents

    Claytor, T.

    1979-10-30

    A method and means for passive detection of a leak in a buried pipe containing fluid under pressure includes a plurality of acoustic detectors that are placed in contact with the pipe. Noise produced by the leak is detected by the detectors, and the detected signals are correlated to locate the leak. In one embodiment of the invention two detectors are placed at different locations to locate a leak between them. In an alternate embodiment two detectors of different waves are placed at substantially the same location to determine the distance of the leak from the location.

  19. Method and means of passive detection of leaks in buried pipes

    DOEpatents

    Claytor, Thomas N.

    1981-01-01

    A method and means for passive detection of a leak in a buried pipe containing fluid under pressure includes a plurality of acoustic detectors that are placed in contact with the pipe. Noise produced by the leak is detected by the detectors, and the detected signals are correlated to locate the leak. In one embodiment of the invention two detectors are placed at different locations to locate a leak between them. In an alternate embodiment two detectors of different waves are placed at substantially the same location to determine the distance of the leak from the location.

  20. Automated Detection of a Crossing Contact Based on Its Doppler Shift

    DTIC Science & Technology

    2009-03-01

    contacts in passive sonar systems. A common approach is the application of high- gain processing followed by successive classification criteria. Most...contacts in passive sonar systems. A common approach is the application of high-gain processing followed by successive classification criteria...RESEARCH MOTIVATION The trade-off between the false alarm and detection probability is fundamental in radar and sonar . (Chevalier, 2002) A common

  1. Detection of chemical pollutants by passive LWIR hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Lavoie, Hugo; Thériault, Jean-Marc; Bouffard, François; Puckrin, Eldon; Dubé, Denis

    2012-09-01

    Toxic industrial chemicals (TICs) represent a major threat to public health and security. Their detection constitutes a real challenge to security and first responder's communities. One promising detection method is based on the passive standoff identification of chemical vapors emanating from the laboratory under surveillance. To investigate this method, the Department of National Defense and Public Safety Canada have mandated Defense Research and Development Canada (DRDC) - Valcartier to develop and test passive Long Wave Infrared (LWIR) hyperspectral imaging (HSI) sensors for standoff detection. The initial effort was focused to address the standoff detection and identification of toxic industrial chemicals (TICs) and precursors. Sensors such as the Multi-option Differential Detection and Imaging Fourier Spectrometer (MoDDIFS) and the Improved Compact ATmospheric Sounding Interferometer (iCATSI) were developed for this application. This paper describes the sensor developments and presents initial results of standoff detection and identification of TICs and precursors. The standoff sensors are based on the differential Fourier-transform infrared (FTIR) radiometric technology and are able to detect, spectrally resolve and identify small leak plumes at ranges in excess of 1 km. Results from a series of trials in asymmetric threat type scenarios will be presented. These results will serve to establish the potential of the method for standoff detection of TICs precursors and surrogates.

  2. Anti-collision radio-frequency identification system using passive SAW tags

    NASA Astrophysics Data System (ADS)

    Sorokin, A. V.; Shepeta, A. P.

    2017-06-01

    Modern multi sensor systems should have high operating speed and resistance to climate impacts. Radiofrequency systems use passive SAW tags for identification items and vehicles. These tags find application in industry, traffic remote control systems, and railway remote traffic control systems for identification and speed measuring. However, collision of the passive SAW RFID tags hinders development passive RFID SAW technology in Industry. The collision problem for passive SAW tags leads for incorrect identification and encoding each tag. In our researching, we suggest approach for identification of several passive SAW tags in collision case.

  3. Site specific probability of passive acoustic detection of humpback whale calls from single fixed hydrophones.

    PubMed

    Helble, Tyler A; D'Spain, Gerald L; Hildebrand, John A; Campbell, Gregory S; Campbell, Richard L; Heaney, Kevin D

    2013-09-01

    Passive acoustic monitoring of marine mammal calls is an increasingly important method for assessing population numbers, distribution, and behavior. A common mistake in the analysis of marine mammal acoustic data is formulating conclusions about these animals without first understanding how environmental properties such as bathymetry, sediment properties, water column sound speed, and ocean acoustic noise influence the detection and character of vocalizations in the acoustic data. The approach in this paper is to use Monte Carlo simulations with a full wave field acoustic propagation model to characterize the site specific probability of detection of six types of humpback whale calls at three passive acoustic monitoring locations off the California coast. Results show that the probability of detection can vary by factors greater than ten when comparing detections across locations, or comparing detections at the same location over time, due to environmental effects. Effects of uncertainties in the inputs to the propagation model are also quantified, and the model accuracy is assessed by comparing calling statistics amassed from 24,690 humpback units recorded in the month of October 2008. Under certain conditions, the probability of detection can be estimated with uncertainties sufficiently small to allow for accurate density estimates.

  4. 26 CFR 1.1375-1 - Tax imposed when passive investment income of corporation having subchapter C earnings and...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Tax imposed when passive investment income of... passive investment income of corporation having subchapter C earnings and profits exceed 25 percent of... on the income of certain S corporations that have passive investment income. In the case of a taxable...

  5. 26 CFR 1.1375-1 - Tax imposed when passive investment income of corporation having subchapter C earnings and...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 11 2011-04-01 2011-04-01 false Tax imposed when passive investment income of... imposed when passive investment income of corporation having subchapter C earnings and profits exceed 25...) imposes a tax on the income of certain S corporations that have passive investment income. In the case of...

  6. Travel patterns and demographic characteristics of malaria cases in Swaziland, 2010-2014.

    PubMed

    Tejedor-Garavito, Natalia; Dlamini, Nomcebo; Pindolia, Deepa; Soble, Adam; Ruktanonchai, Nick W; Alegana, Victor; Le Menach, Arnaud; Ntshalintshali, Nyasatu; Dlamini, Bongani; Smith, David L; Tatem, Andrew J; Kunene, Simon

    2017-09-08

    As Swaziland progresses towards national malaria elimination, the importation of parasites into receptive areas becomes increasingly important. Imported infections have the potential to instigate local transmission and sustain local parasite reservoirs. Travel histories from Swaziland's routine surveillance data from January 2010 to June 2014 were extracted and analysed. The travel patterns and demographics of rapid diagnostic test (RDT)-confirmed positive cases identified through passive and reactive case detection (RACD) were analysed and compared to those found to be negative through RACD. Of 1517 confirmed cases identified through passive surveillance, 67% reported travel history. A large proportion of positive cases reported domestic or international travel history (65%) compared to negative cases (10%). The primary risk factor for malaria infection in Swaziland was shown to be travel, more specifically international travel to Mozambique by 25- to 44-year old males, who spent on average 28 nights away. Maputo City, Inhambane and Gaza districts were the most likely travel destinations in Mozambique, and 96% of RDT-positive international travellers were either Swazi (52%) or Mozambican (44%) nationals, with Swazis being more likely to test negative. All international travellers were unlikely to have a bed net at home or use protection of any type while travelling. Additionally, paths of transmission, important border crossings and means of transport were identified. Results from this analysis can be used to direct national and well as cross-border targeting of interventions, over space, time and by sub-population. The results also highlight that collaboration between neighbouring countries is needed to tackle the importation of malaria at the regional level.

  7. Using stereophotogrammetric technology for obtaining intraoral digital impressions of implants.

    PubMed

    Pradíes, Guillermo; Ferreiroa, Alberto; Özcan, Mutlu; Giménez, Beatriz; Martínez-Rus, Francisco

    2014-04-01

    The procedure for making impressions of multiple implants continues to be a challenge, despite the various techniques proposed to date. The authors' objective in this case report is to describe a novel digital impression method for multiple implants involving the use of stereophotogrammetric technology. The authors present three cases of patients who had multiple implants in which the impressions were obtained with this technology. Initially, a stereo camera with an infrared flash detects the position of special flag abutments screwed into the implants. This process is based on registering the x, y and z coordinates of each implant and the distances between them. This information is converted into a stereolithographic (STL) file. To add the soft-tissue information, the user must obtain another STL file by using an intraoral or extraoral scanner. In the first case presented, this information was acquired from the plaster model with an extraoral scanner; in the second case, from a Digital Imaging and Communication in Medicine (DICOM) file of the plaster model obtained with cone-beam computed tomography; and in the third case, through an intraoral digital impression with a confocal scanner. In the three cases, the frameworks manufactured from this technique showed a correct clinical passive fit. At follow-up appointments held six, 12 and 24 months after insertion of the prosthesis, no complications were reported. Stereophotogrammetric technology is a viable, accurate and easy technique for making multiple implant impressions. Clinicians can use stereophotogrammetric technology to acquire reliable digital master models as a first step in producing frameworks with a correct passive fit.

  8. Passive Endwall Treatments for Enhancing Stability

    NASA Technical Reports Server (NTRS)

    Hathaway, Michael D.

    2007-01-01

    These lecture notes were presented at the von Karman Institutes lecture series on Advances in Axial Compressor Aerodynamics, May 2006. They provide a fairly extensive overview of what's been learned from numerous investigations of various passive casing endwall technologies that have been proposed for alleviating the stall limiting physics associated with the compressor endwall flow field. The lecture notes are organized to give an appreciation for the inventiveness and understanding of the earliest compressor technologists and to provide a coherent thread of understanding that has arisen out of the early investigations. As such the lecture notes begin with a historical overview of casing treatments from their infancy through the earliest proposed concepts involving blowing, suction and flow recirculation. A summary of lessons learned from these early investigations is provided at the end of this section. The lecture notes then provide a somewhat more in-depth overview of recent advancements in the development of passive casing treatments from the late 1990's through 2006, including advancements in understanding the flow mechanism of circumferential groove casing treatments, and the development of discrete tip injection and self-recirculating casing treatments. At the conclusion of the lecture notes a final summary of lessons learned throughout the history of the development of passive casing treatments is provided. Finally, a list of future needs is given. It is hoped that these lecture notes will be a useful reference for future research endeavors to improve our understanding of the fluid physics of passive casing treatments and how they act to enhance compressor stability, and that they will perhaps provide a springboard for future research activities in this area of interest

  9. Flight data acquisition methodology for validation of passive ranging algorithms for obstacle avoidance

    NASA Technical Reports Server (NTRS)

    Smith, Phillip N.

    1990-01-01

    The automation of low-altitude rotorcraft flight depends on the ability to detect, locate, and navigate around obstacles lying in the rotorcraft's intended flightpath. Computer vision techniques provide a passive method of obstacle detection and range estimation, for obstacle avoidance. Several algorithms based on computer vision methods have been developed for this purpose using laboratory data; however, further development and validation of candidate algorithms require data collected from rotorcraft flight. A data base containing low-altitude imagery augmented with the rotorcraft and sensor parameters required for passive range estimation is not readily available. Here, the emphasis is on the methodology used to develop such a data base from flight-test data consisting of imagery, rotorcraft and sensor parameters, and ground-truth range measurements. As part of the data preparation, a technique for obtaining the sensor calibration parameters is described. The data base will enable the further development of algorithms for computer vision-based obstacle detection and passive range estimation, as well as provide a benchmark for verification of range estimates against ground-truth measurements.

  10. New opportunities for quality enhancing of images captured by passive THz camera

    NASA Astrophysics Data System (ADS)

    Trofimov, Vyacheslav A.; Trofimov, Vladislav V.

    2014-10-01

    As it is well-known, the passive THz camera allows seeing concealed object without contact with a person and this camera is non-dangerous for a person. Obviously, efficiency of using the passive THz camera depends on its temperature resolution. This characteristic specifies possibilities of the detection for concealed object: minimal size of the object; maximal distance of the detection; image quality. Computer processing of the THz image may lead to many times improving of the image quality without any additional engineering efforts. Therefore, developing of modern computer code for its application to THz images is urgent problem. Using appropriate new methods one may expect such temperature resolution which will allow to see banknote in pocket of a person without any real contact. Modern algorithms for computer processing of THz images allow also to see object inside the human body using a temperature trace on the human skin. This circumstance enhances essentially opportunity of passive THz camera applications for counterterrorism problems. We demonstrate opportunities, achieved at present time, for the detection both of concealed objects and of clothes components due to using of computer processing of images captured by passive THz cameras, manufactured by various companies. Another important result discussed in the paper consists in observation of both THz radiation emitted by incandescent lamp and image reflected from ceramic floorplate. We consider images produced by THz passive cameras manufactured by Microsemi Corp., and ThruVision Corp., and Capital Normal University (Beijing, China). All algorithms for computer processing of the THz images under consideration in this paper were developed by Russian part of author list. Keywords: THz wave, passive imaging camera, computer processing, security screening, concealed and forbidden objects, reflected image, hand seeing, banknote seeing, ceramic floorplate, incandescent lamp.

  11. Ultrasonic cavitation erosion of Ti in 0.35% NaCl solution with bubbling oxygen and nitrogen.

    PubMed

    Li, D G; Wang, J D; Chen, D R; Liang, P

    2015-09-01

    The influences of oxygen and nitrogen on the ultrasonic cavitation erosion of Ti in 0.35%NaCl solution at room temperature, were investigated using a magnetostrictive-induced ultrasonic cavitation erosion (CE) facility and scanning electron microscopy (SEM). The roles of oxygen and nitrogen in the composition and the electronic property of the passive film on Ti, were studied by Mott-Schottky plot and X-ray photoelectron spectroscopy (XPS). The results showed that the mass loss of Ti in 0.35%NaCl solution increased with increasing cavitation time. Bubbling oxygen can evidently increase the resistance of ultrasonic cavitation erosion comparing with bubbling nitrogen. XPS results showed that the thickness of the passive film on Ti in 0.35%NaCl solution in the case of bubbling oxygen for 3 weeks, was about 7 nm, and the passive film was mainly composed of TiO2 with an anatase structure. While TiO2 with a rutile structure was found to be the major component of the passive film on Ti in 0.35%NaCl solution in the case of bubbling nitrogen for 3 weeks, and the film thickness was 5 nm. The results extracted from Mott-Schottky plot showed that the passive film on Ti in the case of bubbling oxygen had more donor density than the passive film on Ti in the case of bubbling nitrogen. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Passive imaging based multi-cue hazard detection spacecraft safe landing

    NASA Technical Reports Server (NTRS)

    Huertas, Andres; Cheng, Yang; Madison, Richard

    2006-01-01

    Accurate assessment of potentially damaging ground hazards during the spacecraft EDL (Entry, Descent and Landing) phase is crucial to insure a high probability of safe landing. A lander that encounters a large rock, falls off a cliff, or tips over on a steep slope can sustain mission ending damage. Guided entry is expected to shrink landing ellipses from 100-300 km to -10 km radius for the second generation landers as early as 2009. Regardless of size and location, however, landing ellipses will almost always contain hazards such as craters, discontinuities, steep slopes, and large rocks. It is estimated that an MSL (Mars Science Laboratory)-sized lander should detect and avoid 16- 150m diameter craters, vertical drops similar to the edges of 16m or 3.75m diameter crater, for high and low altitude HAD (Hazard Detection and Avoidance) respectively. It should also be able to detect slopes 20' or steeper, and rocks 0.75m or taller. In this paper we will present a passive imaging based, multi-cue hazard detection and avoidance (HDA) system suitable for Martian and other lander missions. This is the first passively imaged HDA system that seamlessly integrates multiple algorithm-crater detection, slope estimation, rock detection and texture analysis, and multicues- crater morphology, rock distribution, to detect these hazards in real time.

  13. Passive Standoff Detection of Chemical Vapors by Differential FTIR Radiometry

    DTIC Science & Technology

    2001-01-01

    8217 utilisation d’un interferometre infrarouge a transformation de Fourier (FTIR) a double entree optimise pour la soustraction optique. En vue de sa mise...Valcartier (DREV) is currently developing a passive Fourier Transform InfraRed (FTIR) technique for the standoff detection and identification of...chemical vapors. A well-known difficulty associated with this technique is that the recorded signal also contains a large amount of unwanted background

  14. Comparison of marine sampling methods for organic contaminants: Passive samplers, water extractions, and live oyster deployment.

    PubMed

    Raub, Kristin B; Vlahos, Penny; Whitney, Michael

    2015-08-01

    Laboratory and field trials evaluated the efficacy of three methods of detecting aquatic pesticide concentrations. Currently used pesticides: atrazine, metolachlor, and diazinon and legacy pesticide dieldrin were targeted. Pesticides were extracted using solid-phase extraction (SPE) of water samples, titanium plate passive samplers coated in ethylene vinyl acetate (EVA) and eastern oysters (Crassostrea viginica) as biosamplers. A laboratory study assessed the extraction efficiencies and precision of each method. Passive samplers yielded the highest precision of the three methods (RSD: 3-14% EVA plates; 19-60% oysters; and 25-56% water samples). Equilibrium partition coefficients were derived. A significant relationship was found between the concentration in oyster tissue and the ambient aquatic concentration. In the field (Housatonic River, CT (U.S.)) water sampling (n = 5) detected atrazine at 1.61-7.31 μg L(-1), oyster sampling (n = 2×15) detected dieldrin at n.d.-0.096 μg L(-1) SW and the passive samplers (n = 5×3) detected atrazine at 0.97-3.78 μg L(-1) SW and dieldrin at n.d.-0.68 μg L(-1) SW. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Pattern recognition for passive polarimetric data using nonparametric classifiers

    NASA Astrophysics Data System (ADS)

    Thilak, Vimal; Saini, Jatinder; Voelz, David G.; Creusere, Charles D.

    2005-08-01

    Passive polarization based imaging is a useful tool in computer vision and pattern recognition. A passive polarization imaging system forms a polarimetric image from the reflection of ambient light that contains useful information for computer vision tasks such as object detection (classification) and recognition. Applications of polarization based pattern recognition include material classification and automatic shape recognition. In this paper, we present two target detection algorithms for images captured by a passive polarimetric imaging system. The proposed detection algorithms are based on Bayesian decision theory. In these approaches, an object can belong to one of any given number classes and classification involves making decisions that minimize the average probability of making incorrect decisions. This minimum is achieved by assigning an object to the class that maximizes the a posteriori probability. Computing a posteriori probabilities requires estimates of class conditional probability density functions (likelihoods) and prior probabilities. A Probabilistic neural network (PNN), which is a nonparametric method that can compute Bayes optimal boundaries, and a -nearest neighbor (KNN) classifier, is used for density estimation and classification. The proposed algorithms are applied to polarimetric image data gathered in the laboratory with a liquid crystal-based system. The experimental results validate the effectiveness of the above algorithms for target detection from polarimetric data.

  16. A passive infrared ice detection technique for helicopter applications

    NASA Technical Reports Server (NTRS)

    Dershowitz, Adam L.; Hansman, R. John, Jr.

    1991-01-01

    A technique has been developed, and successfully tested, to detect icing remotely on helicopter rotor blades. Using passive infrared (IR) thermometry it is possible to detect the warming caused by latent heat released as supercooled water freezes. During icing, the ice accretion region on the leading edge of the blade is found to be warmer than the uniced trailing edge resulting in a chordwise temperature profile characteristic of icing. Preliminary tests, using an IR Thermal video system, were conducted on a static model in the NASA Icing Research Tunnel (IRT) for a variety of wet (glaze) and dry (rime) ice conditions. A prototype detector system was built consisting of a single point IR pyrometer, and experiments were run on a small scale rotor model. Using this prototype detector, the characteristic chordwise temperature profiles were again observed for a range of icing conditions. Several signal processing methods were investigated, to allow automatic recognition of the icing signature. Additionally, several implementation issues were considered. Based on both the static and subscale rotor tests, where ice was successfully detected, the passive IR technique appears to be promising for rotor ice detection.

  17. Establishing a cost-effective national surveillance system for Bluetongue using scenario tree modelling.

    PubMed

    Hadorn, Daniela C; Racloz, Vanessa; Schwermer, Heinzpeter; Stärk, Katharina D C

    2009-01-01

    Vector-borne diseases pose a special challenge to veterinary authorities due to complex and time-consuming surveillance programs taking into account vector habitat. Using stochastic scenario tree modelling, each possible surveillance activity of a future surveillance system can be evaluated with regard to its sensitivity and the expected cost. The overall sensitivity of various potential surveillance systems, composed of different combinations of surveillance activities, is calculated and the proposed surveillance system is optimized with respect to the considered surveillance activities, the sensitivity and the cost. The objective of this project was to use stochastic scenario tree modelling in combination with a simple cost analysis in order to develop the national surveillance system for Bluetongue in Switzerland. This surveillance system was established due to the emerging outbreak of Bluetongue virus serotype 8 (BTV-8) in Northern Europe in 2006. Based on the modelling results, it was decided to implement an improved passive clinical surveillance in cattle and sheep through campaigns in order to increase disease awareness alongside a targeted bulk milk testing strategy in 200 dairy cattle herds located in high-risk areas. The estimated median probability of detection of cases (i.e. sensitivity) of the surveillance system in this combined approach was 96.4%. The evaluation of the prospective national surveillance system predicted that passive clinical surveillance in cattle would provide the highest probability to detect BTV-8 infected animals, followed by passive clinical surveillance in sheep and bulk milk testing of 200 dairy cattle farms in high-risk areas. This approach is also applicable in other countries and to other epidemic diseases.

  18. CATSI EDM: recent advances in the development and validation of a ruggedized passive standoff CWA sensor

    NASA Astrophysics Data System (ADS)

    Lavoie, Hugo; Thériault, Jean-Marc; Bouffard, François; Puckrin, Eldon; Turcotte, Caroline S.; Lacasse, Paul

    2008-04-01

    Defence Research and Development Canada (DRDC) - Valcartier is currently developing a ruggedized passive standoff sensor for the detection of chemical warfare agents (CWAs) based on differential Fourier-transform infrared (FTIR) radiometry. This system is referred to as the Compact ATmospheric Sounding Interferometer (CATSI) Engineering Development Model (EDM). The CATSI EDM sensor is based on the use of a double-beam FTIR spectrometer that is optimized for optical subtraction. A description of the customized sensor is given along with a discussion on the detection and identification approaches that have been developed. Preliminary results of validation from a number of laboratory measurements and open-air trials are analyzed to establish the capability of detection and identification of various toxic and non-toxic chemical vapor plumes. These results clearly demonstrate the capability of the passive differential radiometric approach for the standoff detection and identification of chemical vapors at distances up to a few kilometers from the sensor.

  19. Electrochemical Detection of Platinum(IV) Prodrug Satraplatin in Serum.

    PubMed

    Wu, Yao; Lai, Rebecca Y

    2015-11-03

    We report the design and fabrication of a reagentless and reusable electrochemical sensor for detection of satraplatin (SAT), a platinum(IV) prodrug. The detection strategy is based on the electrocatalytic reaction between the Pt(IV) center of SAT and surface-immobilized methylene blue. We systematically evaluated the effect of passivating diluent chain length on the overall sensor performance. Our results show that the use of a shorter diluent like 2-mercaptoethanol is more advantageous than using a longer and more passivating diluent such as 6-mercapto-1-hexanol. Independent of the use of cyclic voltammetry or chronoamperometry as the sensor interrogation technique, all three sensors, each passivated with a different alkanethiol diluent, have been demonstrated to be sensitive; the limit of detection is in the range of 1-10 μM. They are also highly specific and do not respond to Pt(II) drugs such as cisplatin and carboplatin. More importantly, they are selective enough to be employed directly in 50% serum. This sensing strategy has potential applications in clinical pharmacokinetics studies.

  20. System considerations for detection and tracking of small targets using passive sensors

    NASA Astrophysics Data System (ADS)

    DeBell, David A.

    1991-08-01

    Passive sensors provide only a few discriminants to assist in threat assessment of small targets. Tracking of the small targets provides additional discriminants. This paper discusses the system considerations for tracking small targets using passive sensors, in particular EO sensors. Tracking helps establish good versus bad detections. Discussed are the requirements to be placed on the sensor system's accuracy, with respect to knowledge of the sightline direction. The detection of weak targets sets a requirement for two levels of tracking in order to reduce processor throughput. A system characteristic is the need to track all detections. For low thresholds, this can mean a heavy track burden. Therefore, thresholds must be adaptive in order not to saturate the processors. Second-level tracks must develop a range estimate in order to assess threat. Sensor platform maneuvers are required if the targets are moving. The need for accurate pointing, good stability, and a good update rate will be shown quantitatively, relating to track accuracy and track association.

  1. An Evaluation of Passive and Active Approaches to Improve Tuberculosis Notifications in Afghanistan

    PubMed Central

    Sanaie, A.; Nasrat, A.; Seddiq, M. K.; Mahmoodi, S. D.; Stevens, R. H.; Creswell, J.

    2016-01-01

    Background In Afghanistan, improving TB case detection remains challenging. In 2014, only half of the estimated incident TB cases were notified, and notifications have decreased since peaking in 2007. Active case finding has been increasingly considered to improve TB case notifications. While access to health services has improved in Afghanistan, it remains poor and many people seeking health services won’t receive proper care. Methods From October 2011 through December 2012 we conducted three separate case finding strategies in six provinces of Afghanistan and measured impact on TB case notification. Systematically screening cough among attendees at 47 health facilities, active household contact investigation of smear-positive index TB patients, and active screening at 15 camps for internally displaced people were conducted. We collected both intervention yield and official quarterly notification data. Additional TB notifications were calculated by comparing numbers of cases notified during the intervention with those notified before the intervention, then adjusting for secular trends in notification. Results We screened 2,022,127 people for TB symptoms during the intervention, tested 59,838 with smear microscopy and detected 5,046 people with smear-positive TB. Most cases (81.7%, 4,125) were identified in health facilities while nearly 20% were found through active case finding. A 56% increase in smear-positive TB notifications was observed between the baseline and intervention periods among the 47 health facilities, where cases detected by all three strategies were notified. Discussion While most people with TB are likely to be identified through health facility screening, there are many people who remain without a proper diagnosis if outreach is not attempted. This is especially true in places like Afghanistan where access to general services is poor. Targeted active case finding can improve the number of people who are detected and treated for TB and can push towards the targets of the Stop TB Global Plan and End TB Strategy. PMID:27701446

  2. An Evaluation of Passive and Active Approaches to Improve Tuberculosis Notifications in Afghanistan.

    PubMed

    Sanaie, A; Mergenthaler, C; Nasrat, A; Seddiq, M K; Mahmoodi, S D; Stevens, R H; Creswell, J

    2016-01-01

    In Afghanistan, improving TB case detection remains challenging. In 2014, only half of the estimated incident TB cases were notified, and notifications have decreased since peaking in 2007. Active case finding has been increasingly considered to improve TB case notifications. While access to health services has improved in Afghanistan, it remains poor and many people seeking health services won't receive proper care. From October 2011 through December 2012 we conducted three separate case finding strategies in six provinces of Afghanistan and measured impact on TB case notification. Systematically screening cough among attendees at 47 health facilities, active household contact investigation of smear-positive index TB patients, and active screening at 15 camps for internally displaced people were conducted. We collected both intervention yield and official quarterly notification data. Additional TB notifications were calculated by comparing numbers of cases notified during the intervention with those notified before the intervention, then adjusting for secular trends in notification. We screened 2,022,127 people for TB symptoms during the intervention, tested 59,838 with smear microscopy and detected 5,046 people with smear-positive TB. Most cases (81.7%, 4,125) were identified in health facilities while nearly 20% were found through active case finding. A 56% increase in smear-positive TB notifications was observed between the baseline and intervention periods among the 47 health facilities, where cases detected by all three strategies were notified. While most people with TB are likely to be identified through health facility screening, there are many people who remain without a proper diagnosis if outreach is not attempted. This is especially true in places like Afghanistan where access to general services is poor. Targeted active case finding can improve the number of people who are detected and treated for TB and can push towards the targets of the Stop TB Global Plan and End TB Strategy.

  3. Minimum weight passive insulation requirements for hypersonic cruise vehicles.

    NASA Technical Reports Server (NTRS)

    Ardema, M. D.

    1972-01-01

    Analytical solutions are derived for two representative cases of the transient heat conduction equation to determine the minimum weight requirements for passive insulation systems of hypersonic cruise vehicles. The cases discussed are the wet wall case with the interior wall temperature held to that of the boiling point of the fuel throughout the flight, and the dry wall case where the heat transferred through the insulation is absorbed by the interior structure whose temperature is allowed to rise.

  4. Comparative assessment of passive surveillance in disease-free and endemic situation: Example of Brucella melitensis surveillance in Switzerland and in Bosnia and Herzegovina

    PubMed Central

    Hadorn, Daniela C; Haracic, Sabina Seric; Stärk, Katharina DC

    2008-01-01

    Background Globalization and subsequent growth in international trade in animals and animal products has increased the importance of international disease reporting. Efficient and reliable surveillance systems are needed in order to document the disease status of a population at a given time. In this context, passive surveillance plays an important role in early warning systems. However, it is not yet routinely integrated in the assessment of disease surveillance systems because different factors like the disease awareness (DA) of people reporting suspect cases influence the detection performance of passive surveillance. In this paper, we used scenario tree methodology in order to evaluate and compare the quality and benefit of abortion testing (ABT) for Brucella melitensis (Bm) between the disease free situation in Switzerland (CH) and a hypothetical disease free situation in Bosnia and Herzegovina (BH), taking into account DA levels assumed for the current endemic situation in BH. Results The structure and input parameters of the scenario tree were identical for CH and BH with the exception of population data in small ruminants and the DA in farmers and veterinarians. The sensitivity analysis of the stochastic scenario tree model showed that the small ruminant population structure and the DA of farmers were important influential parameters with regard to the unit sensitivity of ABT in both CH and BH. The DA of both farmers and veterinarians was assumed to be higher in BH than in CH due to the current endemic situation in BH. Although the same DA cannot necessarily be assumed for the modelled hypothetical disease free situation as for the actual endemic situation, it shows the importance of the higher vigilance of people reporting suspect cases on the probability that an average unit processed in the ABT-component would test positive. Conclusion The actual sensitivity of passive surveillance approaches heavily depends on the context in which they are applied. Scenario tree modelling allows for the evaluation of such passive surveillance system components under assumed disease free situation. Despite data gaps, this is a real opportunity to compare different situations and to explore consequences of changes that could be made. PMID:19099610

  5. Comparative assessment of passive surveillance in disease-free and endemic situation: example of Brucella melitensis surveillance in Switzerland and in Bosnia and Herzegovina.

    PubMed

    Hadorn, Daniela C; Haracic, Sabina Seric; Stärk, Katharina D C

    2008-12-22

    Globalization and subsequent growth in international trade in animals and animal products has increased the importance of international disease reporting. Efficient and reliable surveillance systems are needed in order to document the disease status of a population at a given time. In this context, passive surveillance plays an important role in early warning systems. However, it is not yet routinely integrated in the assessment of disease surveillance systems because different factors like the disease awareness (DA) of people reporting suspect cases influence the detection performance of passive surveillance. In this paper, we used scenario tree methodology in order to evaluate and compare the quality and benefit of abortion testing (ABT) for Brucella melitensis (Bm) between the disease free situation in Switzerland (CH) and a hypothetical disease free situation in Bosnia and Herzegovina (BH), taking into account DA levels assumed for the current endemic situation in BH. The structure and input parameters of the scenario tree were identical for CH and BH with the exception of population data in small ruminants and the DA in farmers and veterinarians. The sensitivity analysis of the stochastic scenario tree model showed that the small ruminant population structure and the DA of farmers were important influential parameters with regard to the unit sensitivity of ABT in both CH and BH. The DA of both farmers and veterinarians was assumed to be higher in BH than in CH due to the current endemic situation in BH. Although the same DA cannot necessarily be assumed for the modelled hypothetical disease free situation as for the actual endemic situation, it shows the importance of the higher vigilance of people reporting suspect cases on the probability that an average unit processed in the ABT-component would test positive. The actual sensitivity of passive surveillance approaches heavily depends on the context in which they are applied. Scenario tree modelling allows for the evaluation of such passive surveillance system components under assumed disease free situation. Despite data gaps, this is a real opportunity to compare different situations and to explore consequences of changes that could be made.

  6. Passive infrared bullet detection and tracking

    DOEpatents

    Karr, Thomas J.

    1997-01-01

    An apparatus and method for passively detecting a projectile such as, for example, a bullet using a passive infrared detector. A passive infrared detector is focused onto a region in which a projectile is expected to be located. Successive images of infrared radiation in the region are recorded. Background infrared radiation present in the region is suppressed such that second successive images of infrared radiation generated by the projectile as the projectile passes through the region are produced. A projectile path calculator determines the path and other aspects of the projectile by using the second successive images of infrared radiation generated by the projectile. The present invention, in certain embodiments, also determines the origin of the path of the projectile and takes a photograph of the area surrounding the origin and/or fires at least one projectile at the area surrounding the origin of the path of the projectile.

  7. Passive infrared bullet detection and tracking

    DOEpatents

    Karr, T.J.

    1997-01-21

    An apparatus and method for passively detecting a projectile such as, for example, a bullet using a passive infrared detector. A passive infrared detector is focused onto a region in which a projectile is expected to be located. Successive images of infrared radiation in the region are recorded. Background infrared radiation present in the region is suppressed such that second successive images of infrared radiation generated by the projectile as the projectile passes through the region are produced. A projectile path calculator determines the path and other aspects of the projectile by using the second successive images of infrared radiation generated by the projectile. The present invention, in certain embodiments, also determines the origin of the path of the projectile and takes a photograph of the area surrounding the origin and/or fires at least one projectile at the area surrounding the origin of the path of the projectile. 9 figs.

  8. Evaluation of active and passive near-millimeter-wave radiometric imaging techniques for detection of concealed objects

    NASA Astrophysics Data System (ADS)

    Reber, E. E.; Foote, F. B.; Schellenbaum, R. L.; Bradley, R. G.

    1981-07-01

    The potential of radiometric imaging technique to detect shielded nuclear materials and explosives carried covertly by personnel was investigated. This method of detecting contraband depends upon the differences in emissivity and reflectivity of the contraband relative to human tissue. Explosives, unlike metals and metal composites, generally have high emissivities and low reflectivities that closely approximate those of human tissue making explosives difficult to detect. Samples of several common types of explosives (TNT, Detasheet, C4, and several types of water gels) were examined at the 1.4- and 3-mm wavelengths using active and passive radiometeric techniques.

  9. EGFR Somatic Mutations in Lung Tumors: Radon Exposure and Passive-smoking in Former- and Never-smoking U.S. Women

    PubMed Central

    Taga, Masataka; Mechanic, Leah E.; Hagiwara, Nobutoshi; Vähäkangas, Kirsi H.; Bennett, William P.; Alavanja, Michael C. R.; Welsh, Judith A.; Khan, Mohammed A.; Lee, Adam; Diasio, Robert; Edell, Eric; Bungum, Aaron; Jang, Jin Sung; Yang, Ping; Jen, Jin; Harris, Curtis C.

    2012-01-01

    Background Lung cancer patients with mutations in EGFR tyrosine kinase have improved prognosis when treated with EGFR inhibitors. We hypothesized that EGFR mutations may be related to residential radon or passive tobacco smoke. Methods This hypothesis was investigated by analyzing EGFR mutations in seventy lung tumors from a population of never and long-term former female smokers from Missouri with detailed exposure assessments. The relationship with passive-smoking was also examined in never-smoking female lung cancer cases from the Mayo clinic. Results Overall, the frequency of EGFR mutation was 41% [95% Confidence Interval (CI): 32-49%]. Neither radon nor passive-smoking exposure was consistently associated with EGFR mutations in lung tumors. Conclusions The results suggest that EGFR mutations are common in female, never-smoking, lung cancer cases from the U.S, and EGFR mutations are unlikely due to exposure to radon or passive-smoking. PMID:22523180

  10. Estimating the sensitivity of passive surveillance for HPAI H5N1 in Bayelsa state, Nigeria.

    PubMed

    Ojimelukwe, Agatha E; Prakarnkamanant, Apisit; Rushton, Jonathan

    2016-07-01

    This study identified characteristics of poultry farming with a focus on practices that affect the detection of HPAI; and estimated the system sensitivity of passive surveillance for HPAI H5N1 in commercial and backyard chicken farms in Bayelsa-State, Nigeria. Field studies were carried out in Yenegoa and Ogbia local government areas in Bayelsa state. Willingness to report HPAI was highest in commercial poultry farms (13/13) than in Backyard farms (8/13). Poor means of dead bird disposal was common to both commercial and backyard farms. Administering some form of treatment to sick birds without prior consultation with a professional was higher in backyard farms (8/13) than in commercial farms (4/13). Consumption of sick birds was reported in 4/13 backyard farms and sale of dead birds was recorded in one commercial farm. The sensitivity of passive surveillance for HPAI was assessed using scenario tree modelling. A scenario tree model was developed and applied to estimate the sensitivity, i.e. the probability of detecting one or more infected chicken farms in Bayelsa state at different levels of disease prevalence. The model showed a median sensitivity of 100%, 67% and 23% for detecting HPAI by passive surveillance at a disease prevalence of 0.1%, a minimum of 10 and 3 infected poultry farms respectively. Passive surveillance system sensitivity at a design prevalence of 10 infected farms is increasable up to 86% when the disease detection in backyard chicken farms is enhanced. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Improving the Navy’s Passive Underwater Acoustic Monitoring of Marine Mammal Populations

    DTIC Science & Technology

    2013-09-30

    passive acoustic monitoring: Correcting humpback whale call detections for site-specific and time-dependent environmental characteristics ,” JASA Exp...marine mammal species using passive acoustic monitoring, with application to obtaining density estimates of transiting humpback whale populations in...minimize the variance of the density estimates, 3) to apply the numerical modeling methods for humpback whale vocalizations to understand distortions

  12. Method of remote powering and detecting multiple UWB passive tags in an RFID system

    DOEpatents

    Dowla, Farid U [Castro Valley, CA; Nekoogar, Faranak [San Ramon, CA; Benzel, David M [Livermore, CA; Dallum, Gregory E [Livermore, CA; Spiridon, Alex [Palo Alto, CA

    2012-05-29

    A new Radio Frequency Identification (RFID), tracking, powering apparatus/system and method using coded Ultra-wideband (UWB) signaling is introduced. The proposed hardware and techniques disclosed herein utilize a plurality of passive UWB transponders in a field of an RFID-radar system. The radar system itself enables multiple passive tags to be remotely powered (activated) at about the same time frame via predetermined frequency UWB pulsed formats. Once such tags are in an activated state, an UWB radar transmits specific "interrogating codes" to put predetermined tags in an awakened status. Such predetermined tags can then communicate by a unique "response code" so as to be detected by an UWB system using radar methods.

  13. Sequential dengue virus infections detected in active and passive surveillance programs in Thailand, 1994-2010.

    PubMed

    Bhoomiboonchoo, Piraya; Nisalak, Ananda; Chansatiporn, Natkamol; Yoon, In-Kyu; Kalayanarooj, Siripen; Thipayamongkolgul, Mathuros; Endy, Timothy; Rothman, Alan L; Green, Sharone; Srikiatkhachorn, Anon; Buddhari, Darunee; Mammen, Mammen P; Gibbons, Robert V

    2015-03-14

    The effect of prior dengue virus (DENV) exposure on subsequent heterologous infection can be beneficial or detrimental depending on many factors including timing of infection. We sought to evaluate this effect by examining a large database of DENV infections captured by both active and passive surveillance encompassing a wide clinical spectrum of disease. We evaluated datasets from 17 years of hospital-based passive surveillance and nine years of cohort studies, including clinical and subclinical DENV infections, to assess the outcomes of sequential heterologous infections. Chi square or Fisher's exact test was used to compare proportions of infection outcomes such as disease severity; ANOVA was used for continuous variables. Multivariate logistic regression was used to assess risk factors for infection outcomes. Of 38,740 DENV infections, two or more infections were detected in 502 individuals; 14 had three infections. The mean ages at the time of the first and second detected infections were 7.6 ± 3.0 and 11.2 ± 3.0 years. The shortest time between sequential infections was 66 days. A longer time interval between sequential infections was associated with dengue hemorrhagic fever (DHF) in the second detected infection (OR 1.3, 95% CI 1.2-1.4). All possible sequential serotype pairs were observed among 201 subjects with DHF at the second detected infection, except DENV-4 followed by DENV-3. Among DENV infections detected in cohort subjects by active study surveillance and subsequent non-study hospital-based passive surveillance, hospitalization at the first detected infection increased the likelihood of hospitalization at the second detected infection. Increasing time between sequential DENV infections was associated with greater severity of the second detected infection, supporting the role of heterotypic immunity in both protection and enhancement. Hospitalization was positively associated between the first and second detected infections, suggesting a possible predisposition in some individuals to more severe dengue disease.

  14. Evidence Integration in Natural Acoustic Textures during Active and Passive Listening

    PubMed Central

    Rupp, Andre; Celikel, Tansu

    2018-01-01

    Abstract Many natural sounds can be well described on a statistical level, for example, wind, rain, or applause. Even though the spectro-temporal profile of these acoustic textures is highly dynamic, changes in their statistics are indicative of relevant changes in the environment. Here, we investigated the neural representation of change detection in natural textures in humans, and specifically addressed whether active task engagement is required for the neural representation of this change in statistics. Subjects listened to natural textures whose spectro-temporal statistics were modified at variable times by a variable amount. Subjects were instructed to either report the detection of changes (active) or to passively listen to the stimuli. A subset of passive subjects had performed the active task before (passive-aware vs passive-naive). Psychophysically, longer exposure to pre-change statistics was correlated with faster reaction times and better discrimination performance. EEG recordings revealed that the build-up rate and size of parieto-occipital (PO) potentials reflected change size and change time. Reduced effects were observed in the passive conditions. While P2 responses were comparable across conditions, slope and height of PO potentials scaled with task involvement. Neural source localization identified a parietal source as the main contributor of change-specific potentials, in addition to more limited contributions from auditory and frontal sources. In summary, the detection of statistical changes in natural acoustic textures is predominantly reflected in parietal locations both on the skull and source level. The scaling in magnitude across different levels of task involvement suggests a context-dependent degree of evidence integration. PMID:29662943

  15. Evidence Integration in Natural Acoustic Textures during Active and Passive Listening.

    PubMed

    Górska, Urszula; Rupp, Andre; Boubenec, Yves; Celikel, Tansu; Englitz, Bernhard

    2018-01-01

    Many natural sounds can be well described on a statistical level, for example, wind, rain, or applause. Even though the spectro-temporal profile of these acoustic textures is highly dynamic, changes in their statistics are indicative of relevant changes in the environment. Here, we investigated the neural representation of change detection in natural textures in humans, and specifically addressed whether active task engagement is required for the neural representation of this change in statistics. Subjects listened to natural textures whose spectro-temporal statistics were modified at variable times by a variable amount. Subjects were instructed to either report the detection of changes (active) or to passively listen to the stimuli. A subset of passive subjects had performed the active task before (passive-aware vs passive-naive). Psychophysically, longer exposure to pre-change statistics was correlated with faster reaction times and better discrimination performance. EEG recordings revealed that the build-up rate and size of parieto-occipital (PO) potentials reflected change size and change time. Reduced effects were observed in the passive conditions. While P2 responses were comparable across conditions, slope and height of PO potentials scaled with task involvement. Neural source localization identified a parietal source as the main contributor of change-specific potentials, in addition to more limited contributions from auditory and frontal sources. In summary, the detection of statistical changes in natural acoustic textures is predominantly reflected in parietal locations both on the skull and source level. The scaling in magnitude across different levels of task involvement suggests a context-dependent degree of evidence integration.

  16. A novel and sensitive fluorescence sensor for glutathione detection by controlling the surface passivation degree of carbon quantum dots.

    PubMed

    Pan, Jiahong; Zheng, Zengyao; Yang, Jianying; Wu, Yaoyu; Lu, Fushen; Chen, Yaowen; Gao, Wenhua

    2017-05-01

    A novel fluorescence sensor based on controlling the surface passivation degree of carbon quantum dots (CQDs) was developed for glutathione (GSH) detection. First, we found that the fluorescence intensity of the CQDs which was obtained by directly pyrolyzing citric acid would increased largely after the surface passivation treatment by 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC). In the light of this phenomenon, we designed a simple, rapid and selective fluorescence sensor based on the surface passivated CQDs. A certain and excess amount of EDC were mixed with GSH, part of EDC would form a stable complex with GSH owing to the exposed sulfhydryl group of GSH. As the synthesized CQDs were added into the above mixture solution, the fluorescence intensity of the (EDC/GSH)/CQDs mixture solution could be directly related to the amount of GSH. Compared to other fluorescence analytical methods, the fluorescence sensor we design is neither the traditional fluorescent "turn on" probes nor "turn off" probes. It is a new fluorescence analytical method that target object indirectly control the surface passivation degree of CQDs so that it can realize the detection of the target object. Moreover, the proposed method manifested great advantages including short analysis time, low cost and ease of operation. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Asymptotic Stability of Interconnected Passive Non-Linear Systems

    NASA Technical Reports Server (NTRS)

    Isidori, A.; Joshi, S. M.; Kelkar, A. G.

    1999-01-01

    This paper addresses the problem of stabilization of a class of internally passive non-linear time-invariant dynamic systems. A class of non-linear marginally strictly passive (MSP) systems is defined, which is less restrictive than input-strictly passive systems. It is shown that the interconnection of a non-linear passive system and a non-linear MSP system is globally asymptotically stable. The result generalizes and weakens the conditions of the passivity theorem, which requires one of the systems to be input-strictly passive. In the case of linear time-invariant systems, it is shown that the MSP property is equivalent to the marginally strictly positive real (MSPR) property, which is much simpler to check.

  18. Passive language mapping combining real-time oscillation analysis with cortico-cortical evoked potentials for awake craniotomy.

    PubMed

    Tamura, Yukie; Ogawa, Hiroshi; Kapeller, Christoph; Prueckl, Robert; Takeuchi, Fumiya; Anei, Ryogo; Ritaccio, Anthony; Guger, Christoph; Kamada, Kyousuke

    2016-12-01

    OBJECTIVE Electrocortical stimulation (ECS) is the gold standard for functional brain mapping; however, precise functional mapping is still difficult in patients with language deficits. High gamma activity (HGA) between 80 and 140 Hz on electrocorticography is assumed to reflect localized cortical processing, whereas the cortico-cortical evoked potential (CCEP) can reflect bidirectional responses evoked by monophasic pulse stimuli to the language cortices when there is no patient cooperation. The authors propose the use of "passive" mapping by combining HGA mapping and CCEP recording without active tasks during conscious resections of brain tumors. METHODS Five patients, each with an intraaxial tumor in their dominant hemisphere, underwent conscious resection of their lesion with passive mapping. The authors performed functional localization for the receptive language area, using real-time HGA mapping, by listening passively to linguistic sounds. Furthermore, single electrical pulses were delivered to the identified receptive temporal language area to detect CCEPs in the frontal lobe. All mapping results were validated by ECS, and the sensitivity and specificity were evaluated. RESULTS Linguistic HGA mapping quickly identified the language area in the temporal lobe. Electrical stimulation by linguistic HGA mapping to the identified temporal receptive language area evoked CCEPs on the frontal lobe. The combination of linguistic HGA and frontal CCEPs needed no patient cooperation or effort. In this small case series, the sensitivity and specificity were 93.8% and 89%, respectively. CONCLUSIONS The described technique allows for simple and quick functional brain mapping with higher sensitivity and specificity than ECS mapping. The authors believe that this could improve the reliability of functional brain mapping and facilitate rational and objective operations. Passive mapping also sheds light on the underlying physiological mechanisms of language in the human brain.

  19. Effects of HIFU induced cavitation on flooded lung parenchyma.

    PubMed

    Wolfram, Frank; Dietrich, Georg; Boltze, Carsten; Jenderka, Klaus Vitold; Lesser, Thomas Günther

    2017-01-01

    High intensity focused ultrasound (HIFU) has gained clinical interest as a non-invasive local tumour therapy in many organs. In addition, it has been shown that lung cancer can be targeted by HIFU using One-Lung Flooding (OLF). OLF generates a gas free saline-lung compound in one lung wing and therefore acoustic access to central lung tumours. It can be assumed that lung parenchyma is exposed to ultrasound intensities in the pre-focal path and in cases of misguiding. If so, cavitation might be induced in the saline fraction of flooded lung and cause tissue damage. Therefore this study was aimed to determine the thresholds of HIFU induced cavitation and tissue erosion in flooded lung. Resected human lung lobes were flooded ex-vivo. HIFU (1,1 MHz) was targeted under sonographic guidance into flooded lung parenchyma. Cavitation events were counted using subharmonic passive cavitation detection (PCD). B-Mode imaging was used to detect cavitation and erosion sonographically. Tissue samples out of the focal zone were analysed histologically. In flooded lung, a PCD and a sonographic cavitation detection threshold of 625  Wcm - 2 ( p r  = 4, 3  MPa ) and 3.600  Wcm - 2 ( p r  = 8, 3  MPa ) was found. Cavitation in flooded lung appears as blurred hyperechoic focal region, which enhances echogenity with insonation time. Lung parenchyma erosion was detected at intensities above 7.200  Wcm - 2 ( p r  = 10, 9  MPa ). Cavitation occurs in flooded lung parenchyma, which can be detected passively and by B-Mode imaging. Focal intensities required for lung tumour ablation are below levels where erosive events occur. Therefore focal cavitation events can be monitored and potential risk from tissue erosion in flooded lung avoided.

  20. Effect of Ultrasonic Nano-Crystal Surface Modification (UNSM) on the Passivation Behavior of Aged 316L Stainless Steel

    PubMed Central

    Kim, Ki-Tae; Lee, Jung-Hee; Kim, Young-Sik

    2017-01-01

    Stainless steels have good corrosion resistance in many environments but welding or aging can decrease their resistance. This work focused on the effect of aging time and ultrasonic nano-crystal surface modification on the passivation behavior of 316L stainless steel. In the case of slightly sensitized 316L stainless steel, increasing the aging time drastically decreased the pitting potential, increased the passive current density, and decreased the resistance of the passive film, even though aging did not form chromium carbide and a chromium depletion zone. This behavior is due to the micro-galvanic corrosion between the matrix and carbon segregated area, and this shows the importance of carbon segregation in grain boundaries to the pitting corrosion resistance of stainless steel, in addition to the formation of the chromium depletion zone. UNSM (Ultrasonic Nano Crystal Surface Modification)-treatment to the slightly sensitized 316L stainless steel increased the pitting potential, decreased the passive current density, and increased the resistance of the passive film. However, in the case of heavily sensitized 316L stainless steel, UNSM-treatment decreased the pitting potential, increased the passive current density, and decreased the resistance of the passive film. This behavior is due to the dual effects of the UNSM-treatment. That is, the UNSM-treatment reduced the carbon segregation, regardless of whether the stainless steel 316L was slightly or heavily sensitized. However, since this treatment made mechanical flaws in the outer surface in the case of the heavily sensitized stainless steel, UNSM-treatment may eliminate chromium carbide, and this flaw can be a pitting initiation site, and therefore decrease the pitting corrosion resistance. PMID:28773067

  1. Effect of Ultrasonic Nano-Crystal Surface Modification (UNSM) on the Passivation Behavior of Aged 316L Stainless Steel.

    PubMed

    Kim, Ki-Tae; Lee, Jung-Hee; Kim, Young-Sik

    2017-06-27

    Stainless steels have good corrosion resistance in many environments but welding or aging can decrease their resistance. This work focused on the effect of aging time and ultrasonic nano-crystal surface modification on the passivation behavior of 316L stainless steel. In the case of slightly sensitized 316L stainless steel, increasing the aging time drastically decreased the pitting potential, increased the passive current density, and decreased the resistance of the passive film, even though aging did not form chromium carbide and a chromium depletion zone. This behavior is due to the micro-galvanic corrosion between the matrix and carbon segregated area, and this shows the importance of carbon segregation in grain boundaries to the pitting corrosion resistance of stainless steel, in addition to the formation of the chromium depletion zone. UNSM (Ultrasonic Nano Crystal Surface Modification)-treatment to the slightly sensitized 316L stainless steel increased the pitting potential, decreased the passive current density, and increased the resistance of the passive film. However, in the case of heavily sensitized 316L stainless steel, UNSM-treatment decreased the pitting potential, increased the passive current density, and decreased the resistance of the passive film. This behavior is due to the dual effects of the UNSM-treatment. That is, the UNSM-treatment reduced the carbon segregation, regardless of whether the stainless steel 316L was slightly or heavily sensitized. However, since this treatment made mechanical flaws in the outer surface in the case of the heavily sensitized stainless steel, UNSM-treatment may eliminate chromium carbide, and this flaw can be a pitting initiation site, and therefore decrease the pitting corrosion resistance.

  2. Aspects and Some Results on Passivity and Positivity of Dynamic Systems

    NASA Astrophysics Data System (ADS)

    De la Sen, M.

    2017-12-01

    This paper is devoted to discuss certain aspects of passivity results in dynamic systems and the characterization of the regenerative systems counterparts. In particular, the various concepts of passivity as standard passivity, strict input passivity, strict output passivity and very strict passivity (i.e. joint strict input and output passivity) are given and related to the existence of a storage function and a dissipation function. Later on, the obtained results are related to external positivity of systems and positivity or strict positivity of the transfer matrices and transfer functions in the time-invariant case. On the other hand, it is discussed how to achieve or how eventually to increase the passivity effects via linear feedback by the synthesis of the appropriate feed-forward or feedback controllers or, simply, by adding a positive parallel direct input-output matrix interconnection gain.

  3. Focal Plane Array Technology for IR Detectors

    DTIC Science & Technology

    1996-06-01

    samples are determined. Our results on p-(HgCd)Te coated with passivation layers are evident from Figs 3.1 and 3.2. In the first case (native sulphides ...samples are evident from the Table II. We studied influence of (a) atmosphere, (b) ZnS passivation, (c) native sulphides + ZnS passivation. The (HgCd)Te...native sulphides + ZnS, full symbols RH<O, open symbols RH>O. 10 5 6408A3 10- 010o E 102 000 2 days after passivation 10 : 80 days after passivation 0

  4. Adding tsetse control to medical activities contributes to decreasing transmission of sleeping sickness in the Mandoul focus (Chad).

    PubMed

    Mahamat, Mahamat Hissene; Peka, Mallaye; Rayaisse, Jean-Baptiste; Rock, Kat S; Toko, Mahamat Abdelrahim; Darnas, Justin; Brahim, Guihini Mollo; Alkatib, Ali Bachar; Yoni, Wilfrid; Tirados, Inaki; Courtin, Fabrice; Brand, Samuel P C; Nersy, Cyrus; Alfaroukh, Idriss Oumar; Torr, Steve J; Lehane, Mike J; Solano, Philippe

    2017-07-01

    Gambian sleeping sickness or HAT (human African trypanosomiasis) is a neglected tropical disease caused by Trypanosoma brucei gambiense transmitted by riverine species of tsetse. A global programme aims to eliminate the disease as a public health problem by 2020 and stop transmission by 2030. In the South of Chad, the Mandoul area is a persistent focus of Gambian sleeping sickness where around 100 HAT cases were still diagnosed and treated annually until 2013. Pre-2014, control of HAT relied solely on case detection and treatment, which lead to a gradual decrease in the number of cases of HAT due to annual screening of the population. Because of the persistence of transmission and detection of new cases, we assessed whether the addition of vector control to case detection and treatment could further reduce transmission and consequently, reduce annual incidence of HAT in Mandoul. In particular, we investigated the impact of deploying 'tiny targets' which attract and kill tsetse. Before tsetse control commenced, a census of the human population was conducted and their settlements mapped. A pre-intervention survey of tsetse distribution and abundance was implemented in November 2013 and 2600 targets were deployed in the riverine habitats of tsetse in early 2014, 2015 and 2016. Impact on tsetse and on the incidence of sleeping sickness was assessed through nine tsetse monitoring surveys and four medical surveys of the human population in 2014 and 2015. Mathematical modelling was used to assess the relative impact of tsetse control on incidence compared to active and passive screening. The census indicated that a population of 38674 inhabitants lived in the vicinity of the Mandoul focus. Within this focus in November 2013, the vector is Glossina fuscipes fuscipes and the mean catch of tsetse from traps was 0.7 flies/trap/day (range, 0-26). The catch of tsetse from 44 sentinel biconical traps declined after target deployment with only five tsetse being caught in nine surveys giving a mean catch of 0.005 tsetse/trap/day. Modelling indicates that 70.4% (95% CI: 51-95%) of the reduction in reported cases between 2013 and 2015 can be attributed to vector control with the rest due to medical intervention. Similarly tiny targets are estimated to have reduced new infections dramatically with 62.8% (95% CI: 59-66%) of the reduction due to tsetse control, and 8.5% (95% 8-9%) to enhanced passive detection. Model predictions anticipate that elimination as a public health problem could be achieved by 2018 in this focus if vector control and screening continue at the present level and, furthermore, there may have been virtually no transmission since 2015. This work shows that tiny targets reduced the numbers of tsetse in this focus in Chad, which may have interrupted transmission and the combination of tsetse control to medical detection and treatment has played a major role in reducing in HAT incidence in 2014 and 2015.

  5. Characterization of the epidemiology of bat-borne rabies in Chile between 2003 and 2013.

    PubMed

    Alegria-Moran, Raul; Miranda, Daniela; Barnard, Matt; Parra, Alonso; Lapierre, Lisette

    2017-08-01

    Rabies is a zoonotic disease of great impact to public health. According to the World Health Organization, the country of Chile is currently declared free from human rabies transmitted by dogs. An epidemiological characterization and description was conducted using rabies data from 2003 to 2013 held by the National Program for Prevention and Control of Rabies from the Ministry of Health, consisting of bats samples reported as suspect and samples taken by active surveillance (bats brain tissue). Spatial autocorrelation analysis was performed using Local Indicators of Spatial Association (LISA) statistics, particularly Moran's I index, for the detection of spatial clusters. Temporal descriptive analysis was also carried out. Nine hundred and twenty-seven positive cases were reported, presenting an average of 84 cases per year, mainly originated from passive surveillance (98.5%), whilst only 1.5% of cases were reported by active surveillance. Global positivity for the study period was 7.02% and 0.1% in passive and active surveillance respectively. Most of the cases were reported in the central zone of Chile (88.1%), followed by south zone (9.1%) and north zone (2.8%). At a regional level, Metropolitana (40.6%), Valparaíso (19.1%) and Maule (11.8%) regions reported the majority of the cases. Tadarida brasiliensis (92%) presented the majority of the cases reported, with viral variant 4 (82%) being most commonly diagnosed. Only two cases were detected in companion animals. The central zone presented a positive spatial autocorrelation (Moran's I index=0.1537, 95% CI=0.1141-0.1933; p-value=0.02); north and south zones returned non-significant results (Moran's I index=0.0517 and -0.0117, 95% CI=-0.0358-0.1392 and -0.0780-0.0546, and p-values=0.21 and 0.34 respectively). The number of rabies cases decreased between May and August (late fall and winter) and tended to increase during the hot season (December to March), confirmed with the evidence from Autocorrelation analysis and the Ljun-Box test (X 2 =234.85 and p-value<0.0001). Knowledge of animal rabies epidemiologic behaviour becomes relevant when designing prevention and control measures and surveillance programs. This is especially important considering the high impact to Public Health of this disease and that wildlife rabies in bats remains endemic in Chile. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Cellular automaton formulation of passive scalar dynamics

    NASA Technical Reports Server (NTRS)

    Chen, Hudong; Matthaeus, William H.

    1987-01-01

    Cellular automata modeling of the advection of a passive scalar in a two-dimensional flow is examined in the context of discrete lattice kinetic theory. It is shown that if the passive scalar is represented by tagging or 'coloring' automation particles a passive advection-diffusion equation emerges without use of perturbation expansions. For the specific case of the hydrodynamic lattice gas model of Frisch et al. (1986), the diffusion coefficient is calculated by perturbation.

  7. Spiny lobsters detect conspecific blood-borne alarm cues exclusively through olfactory sensilla.

    PubMed

    Shabani, Shkelzen; Kamio, Michiya; Derby, Charles D

    2008-08-01

    When attacked by predators, diverse animals actively or passively release molecules that evoke alarm and related anti-predatory behavior by nearby conspecifics. The actively released molecules are alarm pheromones, whereas the passively released molecules are alarm cues. For example, many insects have alarm-signaling systems that involve active release of alarm pheromones from specialized glands and detection of these signals using specific sensors. Many crustaceans passively release alarm cues, but the nature of the cues, sensors and responses is poorly characterized. Here we show in laboratory and field experiments that injured Caribbean spiny lobsters, Panulirus argus, passively release alarm cues via blood (hemolymph) that induce alarm responses in the form of avoidance and suppression of feeding. These cues are detected exclusively through specific olfactory chemosensors, the aesthetasc sensilla. The alarm cues for Caribbean spiny lobsters are not unique to the species but do show some phylogenetic specificity: P. argus responds primarily with alarm behavior to conspecific blood, but with mixed alarm and appetitive behaviors to blood from the congener Panulirus interruptus, or with appetitive behaviors to blood from the blue crab Callinectes sapidus. This study lays the foundation for future neuroethological studies of alarm cue systems in this and other decapod crustaceans.

  8. Factors Facilitating Implicit Learning: The Case of the Sesotho Passive

    ERIC Educational Resources Information Center

    Kline, Melissa; Demuth, Katherine

    2010-01-01

    Researchers have long debated the mechanisms underlying the learning of syntactic structure. Of significant interest has been the fact that passive constructions appear to be learned earlier in Sesotho than English. This paper provides a comprehensive, quantitative analysis of the passive input Sesotho-speaking children hear, how it differs from…

  9. Can you hear me now? Range-testing a submerged passive acoustic receiver array in a Caribbean coral reef habitat

    USGS Publications Warehouse

    Selby, Thomas H.; Hart, Kristen M.; Fujisaki, Ikuko; Smith, Brian J.; Pollock, Clayton J; Hillis-Star, Zandy M; Lundgren, Ian; Oli, Madan K.

    2016-01-01

    Submerged passive acoustic technology allows researchers to investigate spatial and temporal movement patterns of many marine and freshwater species. The technology uses receivers to detect and record acoustic transmissions emitted from tags attached to an individual. Acoustic signal strength naturally attenuates over distance, but numerous environmental variables also affect the probability a tag is detected. Knowledge of receiver range is crucial for designing acoustic arrays and analyzing telemetry data. Here, we present a method for testing a relatively large-scale receiver array in a dynamic Caribbean coastal environment intended for long-term monitoring of multiple species. The U.S. Geological Survey and several academic institutions in collaboration with resource management at Buck Island Reef National Monument (BIRNM), off the coast of St. Croix, recently deployed a 52 passive acoustic receiver array. We targeted 19 array-representative receivers for range-testing by submersing fixed delay interval range-testing tags at various distance intervals in each cardinal direction from a receiver for a minimum of an hour. Using a generalized linear mixed model (GLMM), we estimated the probability of detection across the array and assessed the effect of water depth, habitat, wind, temperature, and time of day on the probability of detection. The predicted probability of detection across the entire array at 100 m distance from a receiver was 58.2% (95% CI: 44.0–73.0%) and dropped to 26.0% (95% CI: 11.4–39.3%) 200 m from a receiver indicating a somewhat constrained effective detection range. Detection probability varied across habitat classes with the greatest effective detection range occurring in homogenous sand substrate and the smallest in high rugosity reef. Predicted probability of detection across BIRNM highlights potential gaps in coverage using the current array as well as limitations of passive acoustic technology within a complex coral reef environment.

  10. Passive exposure to nicotine from e-cigarettes.

    PubMed

    Gallart-Mateu, D; Elbal, L; Armenta, S; de la Guardia, M

    2016-05-15

    A procedure based on the use of ion mobility spectrometry (IMS), after liquid-liquid microextraction (LLME), has been successfully employed for the determination of passive exposure to nicotine from cigarette and e-cigarette smoking. Nicotine has been determined in exhaled breath and oral fluids of both, active and passive smokers. The aforementioned studies, made in closed environments, evidenced that the exhaled breath after conventional blend cigarette smoke provides nicotine levels of the order of 220 ng per puff, in the case of experienced smokers, being exhaled only 32 ng in the case of e-cigarettes. On the other hand, the nicotine amount in oral fluids of passive vapers was between 8 and 14 µg L(-1) lower than the average value of 38±14 µg L(-1) found for passive smokers of rolling tobacco and clearly lower than the 79±36 µg L(-1) obtained from passive smokers of classical yellow blend. This study was also placed in the frame of the verification of the e-cigarettes composition. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Surveillance for pneumonic plague in the United States during an international emergency: a model for control of imported emerging diseases.

    PubMed Central

    Fritz, C. L.; Dennis, D. T.; Tipple, M. A.; Campbell, G. L.; McCance, C. R.; Gubler, D. J.

    1996-01-01

    In September 1994, in response to a reported epidemic of plague in India, the Centers for Disease Control and Prevention (CDC) enhanced surveillance in the United States for imported pneumonic plague. Plague information materials were rapidly developed and distributed to U.S. public health officials by electronic mail, facsimile, and expedited publication. Information was also provided to medical practitioners and the public by recorded telephone messages and facsimile transmission. Existing quarantine protocols were modified to effect active surveillance for imported plague cases at U.S. airports. Private physicians and state and local health departments were relied on in a passive surveillance system to identify travelers with suspected plague not detected at airports. From September 27 to October 27, the surveillance system identified 13 persons with suspected plague; no case was confirmed. This coordinated response to an international health emergency may serve as a model for detecting other emerging diseases and preventing their importation. PMID:8964057

  12. Surveillance for pneumonic plague in the United States during an international emergency: a model for control of imported emerging diseases.

    PubMed

    Fritz, C L; Dennis, D T; Tipple, M A; Campbell, G L; McCance, C R; Gubler, D J

    1996-01-01

    In September 1994, in response to a reported epidemic of plague in India, the Centers for Disease Control and Prevention (CDC) enhanced surveillance in the United States for imported pneumonic plague. Plague information materials were rapidly developed and distributed to U.S. public health officials by electronic mail, facsimile, and expedited publication. Information was also provided to medical practitioners and the public by recorded telephone messages and facsimile transmission. Existing quarantine protocols were modified to effect active surveillance for imported plague cases at U.S. airports. Private physicians and state and local health departments were relied on in a passive surveillance system to identify travelers with suspected plague not detected at airports. From September 27 to October 27, the surveillance system identified 13 persons with suspected plague; no case was confirmed. This coordinated response to an international health emergency may serve as a model for detecting other emerging diseases and preventing their importation.

  13. Exposure to passive smoking and rheumatoid arthritis risk: results from the Swedish EIRA study.

    PubMed

    Hedström, Anna Karin; Klareskog, Lars; Alfredsson, Lars

    2018-07-01

    Smoking has consistently been associated with increased risk of developing rheumatoid arthritis (RA). The aim of this study was to estimate the influence of passive smoking on the risk of developing anti-cyclic citrullinated peptide antibodies (ACPA)-positive and ACPA-negative RA. A population-based case-control study using incident cases of RA was performed in Sweden, and the study population in this report was restricted to include never-smokers (589 cases, 1764 controls). The incidence of RA among never-smokers who had been exposed to passive smoking was compared with that of never-smokers who had never been exposed, by calculating the OR with a 95% CI employing logistic regression. No association was observed between exposure to passive smoking and RA risk (OR 1.0, 95% CI 0.8 to 1.2 for ACPA-positive RA, and OR 0.9, 95% CI 0.7 to 1.2, for ACPA-negative RA). No suggestion of a trend between duration of passive smoking and RA risk was observed. No association was observed between exposure to passive smoking and RA risk, which may be explained by a threshold below which no association between smoke exposure and RA occurs. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Evaluation of the Loop Mediated Isothermal DNA Amplification (LAMP) Kit for Malaria Diagnosis in P. vivax Endemic Settings of Colombia

    PubMed Central

    Vallejo, Andrés F.; Martínez, Nora L.; González, Iveth J.; Arévalo-Herrera, Myriam; Herrera, Sócrates

    2015-01-01

    Background Most commonly used malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections which are frequent in low transmission settings. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too laborious for field deployment. In this study, the applicability of a malaria diagnosis kit based on loop-mediated isothermal amplification (mLAMP) was assessed in malaria endemic areas of Colombia with Plasmodium vivax predominance. Methodology/Principal Findings First, a passive case detection (PCD) study on 278 febrile patients recruited in Tierralta (department of Cordoba) was conducted to assess the diagnostic performance of the mLAMP method. Second, an active case detection (ACD) study on 980 volunteers was conducted in 10 sentinel sites with different epidemiological profiles. Whole blood samples were processed for microscopic and mLAMP diagnosis. Additionally RT-PCR and nested RT-PCR were used as reference tests. In the PCD study, P. falciparum accounted for 23.9% and P. vivax for 76.1% of the infections and no cases of mixed-infections were identified. Microscopy sensitivity for P. falciparum and P. vivax were 100% and 86.1%, respectively. mLAMP sensitivity for P. falciparum and P. vivax was 100% and 91.4%, respectively. In the ACD study, mLAMP detected 65 times more cases than microscopy. A high proportion (98.0%) of the infections detected by mLAMP was from volunteers without symptoms. Conclusions/Significance mLAMP sensitivity and specificity were comparable to RT-PCR. LAMP was significantly superior to microscopy and in P. vivax low-endemicity settings and under minimum infrastructure conditions, it displayed sensitivity and specificity similar to that of single-well RT-PCR for detection of both P. falciparum and P. vivax infections. Here, the dramatically increased detection of asymptomatic malaria infections by mLAMP demonstrates the usefulness of this new tool for diagnosis, surveillance, and screening in elimination strategies. PMID:25569550

  15. Fabrication of microfluidic integrated biosensor

    NASA Astrophysics Data System (ADS)

    Adam, Tijjani; Dhahi, Th S.; Mohammed, Mohammed; Hashim, U.; Noriman, N. Z.; Dahham, Omar S.

    2017-09-01

    An event of miniaturizing for sensor systems to carry out biological diagnostics are gaining wade spread acceptance. The system may contain several different sensor units for the detection of specific analyte, the analyte to be detected might be any kind of biological molecules (DNA, mRNA or proteins) or chemical substances. In most cases, the detection is based on receptor-ligand binding like DNA hybridization or antibody-antigen interaction, achieving this on a nanostructure. DNA or protein must be attached to certain locations within the structure. Critical for this is to have a robust binding chemistry to the surface in the microstructure. Here we successfully designed and fabricated microfluidics element for passive fluid delivery into polysilicon Nanowire sensing domain, we further demonstrated a very simple and effective way of integrating the two devices to give full functionalities of laboratory on a single chip. The sensing element was successfully surface modified and tested on real biomedical clinical sample for evaluation and validation.

  16. First experience with Remote Sensing methods and selected sensors in the monitoring of mining areas - a case study of the Belchatow open cast mine

    NASA Astrophysics Data System (ADS)

    Wajs, Jaroslaw

    2018-01-01

    The paper presents satellite imagery from active SENTINEL-1A and passive SENTINEL-2A/2B sensors for their application in the monitoring of mining areas focused on detecting land changes. Multispectral scenes of SENTINEL-2A/2B have allowed for detecting changes in land-cover near the region of interest (ROI), i.e. the Szczercow dumping site in the Belchatow open cast lignite mine, central Poland, Europe. Scenes from SENTINEL-1A/1B satellite have also been used in the research. Processing of the SLC signal enabled creating a return intensity map in VV polarization. The obtained SAR scene was reclassified and shows a strong return signal from the dumping site and the open pit. This fact may be used in detection and monitoring of changes occurring within the analysed engineering objects.

  17. Multiplex Detection of KRAS Mutations Using Passive Droplet Fusion.

    PubMed

    Pekin, Deniz; Taly, Valerie

    2017-01-01

    We describe a droplet microfluidics method to screen for multiple mutations of a same oncogene in a single experiment using passive droplet fusion. Genomic DNA from H1573 cell-line was screened for the presence of the six common mutations of the KRAS oncogene as well as wild-type sequences with a detection efficiency of 98 %. Furthermore, the mutant allelic fraction of the cell-line was also assessed correctly showing that the technique is quantitative.

  18. Techniques for active passivation

    DOEpatents

    Roscioli, Joseph R.; Herndon, Scott C.; Nelson, Jr., David D.

    2016-12-20

    In one embodiment, active (continuous or intermittent) passivation may be employed to prevent interaction of sticky molecules with interfaces inside of an instrument (e.g., an infrared absorption spectrometer) and thereby improve response time. A passivation species may be continuously or intermittently applied to an inlet of the instrument while a sample gas stream is being applied. The passivation species may have a highly polar functional group that strongly binds to either water or polar groups of the interfaces, and once bound presents a non-polar group to the gas phase in order to prevent further binding of polar molecules. The instrument may be actively used to detect the sticky molecules while the passivation species is being applied.

  19. Hydrodynamic interactions between a self-rotation rotator and passive particles

    NASA Astrophysics Data System (ADS)

    Ouyang, Zhenyu; Lin, Jian-Zhong; Ku, Xiaoke

    2017-10-01

    In this paper, we numerically investigate the hydrodynamic interaction between a self-rotation rotator and passive particles in a two-dimensional confined cavity at two typical Reynolds numbers according to the different flow features. Both the fluid-particle interaction and particle-particle interaction through fluid media are taken into consideration. The results show that from the case of a rotator and one passive particle to the case of a rotator and two passive particles, the system becomes much more complex because the relative displacement between the rotator and the passive particles and the velocity of passive particles are strongly dependent on the Reynolds number and the initial position of passive particles. For the system of two particles, the passive particle gradually departs from the rotator although its relative displacement to the rotator exhibits a periodic oscillation at the lower Reynolds number. Furthermore, the relative distance between the two particles and the rotator's rotational frequency are responsible for the oscillation amplitude and frequency of the passive particle's velocity. For the system of three particles, the passive particle's velocities exhibit a superposition of a large amplitude oscillation and a small amplitude oscillation at the lower Reynolds number, and the large amplitude oscillation will disappear at the higher Reynolds number. The change of the included angle of the two passive particles is dependent on the initial positions of the passive particles at the lower Reynolds number, whereas the included angle of the two passive particles finally approaches a fixed value at the higher Reynolds number. It is interesting that the two passive particles periodically approach and depart from each other when the included angle is not equal to π, while all the three particles (including the rotator) keep the positions in a straight line when the included angle is equal to π because the interference between two passive particles disappears. In addition, the passive particle rotates not only around the rotator but also around its own axis, and the rotation speed of the former is far greater than that of the latter.

  20. Generation and transmission of DPSK signals using a directly modulated passive feedback laser.

    PubMed

    Karar, Abdullah S; Gao, Ying; Zhong, Kang Ping; Ke, Jian Hong; Cartledge, John C

    2012-12-10

    The generation of differential-phase-shift keying (DPSK) signals is demonstrated using a directly modulated passive feedback laser at 10.709-Gb/s, 14-Gb/s and 16-Gb/s. The quality of the DPSK signals is assessed using both noncoherent detection for a bit rate of 10.709-Gb/s and coherent detection with digital signal processing involving a look-up table pattern-dependent distortion compensator. Transmission over a passive link consisting of 100 km of single mode fiber at a bit rate of 10.709-Gb/s is achieved with a received optical power of -45 dBm at a bit-error-ratio of 3.8 × 10(-3) and a 49 dB loss margin.

  1. I-SCAD® standoff chemical agent detector overview

    NASA Astrophysics Data System (ADS)

    Popa, Mirela O.; Griffin, Matthew T.

    2012-06-01

    This paper presents a system-level description of the I-SCAD® Standoff Chemical Agent Detector, a passive Fourier Transform InfraRed (FTIR) based remote sensing system, for detecting chemical vapor threats. The passive infrared detection system automatically searches the 7 to 14 micron region of the surrounding atmosphere for agent vapor clouds. It is capable of operating while on the move to accomplish reconnaissance, surveillance, and contamination avoidance missions. Additionally, the system is designed to meet the needs for application on air and sea as well as ground mobile and fixed site platforms. The lightweight, passive, and fully automatic detection system scans the surrounding atmosphere for chemical warfare agent vapors. It provides on-the-move, 360-deg coverage from a variety of tactical and reconnaissance platforms at distances up to 5 km. The core of the system is a rugged Michelson interferometer with a flexure spring bearing mechanism and bi-directional data acquisition capability. The modular system design facilitates interfacing to many platforms. A Reduced Field of View (RFOV) variant includes novel modifications to the scanner subcomponent assembly optical design that gives extended performance in detection range and detection probability without sacrificing existing radiometric sensitivity performance. This paper will deliver an overview of system.

  2. How Can We Identify the Elimination of Infectious Diseases? Experience From an Active Measles Laboratory Surveillance System in the Republic of Korea.

    PubMed

    Yang, Tae Un; Kang, Hae Ji; Eom, Hye Eun; Park, Young-Joon; Park, Ok; Kim, Su Jin; Nam, Jeong-Gu; Kim, Sung Soon; Jeong, Eun Kyeong

    2015-11-01

    Global efforts have markedly decreased the disease burden of vaccine-preventable diseases. Many countries have made considerable progress toward the elimination of measles. As elimination is approached, the very low incidence achieved by high vaccination coverage has underscored the need for a sensitive and timely surveillance system. In the Republic of Korea, an active laboratory surveillance system (ALSS) was implemented to supplement the existing passive surveillance system in 2006. The ALSS connects 5 major commercial laboratories and the national measles reference laboratory, where referred samples with positive or equivocal results are retested. Annually, from 2009 to 2013, 3714 suspected cases were detected through the ALSS, an expansion of 8- to 57-fold, compared with only the passive surveillance system. The ALSS, with its sensitivity and timeliness, is a reasonable strategy to supplement the existing measles surveillance system and to help identify the elimination of measles. © 2015 APJPH.

  3. An intercomparison for NIRS and NYU passive thoron gas detectors at NYU.

    PubMed

    Sorimachi, Atsuyuki; Ishikawa, Tetsuo; Tokonami, Shinji; Chittaporn, Passaporn; Harley, Naomi H

    2012-04-01

    An intercomparison on thoron ((220)Rn) measurement was carried out between National Institute of Radiological Sciences, Japan (NIRS), and New York University School of Medicine, USA (NYU). The measurements of (220)Rn concentration at NIRS and NYU were performed by using the scintillation cell method and the two-filter method, respectively, as the standard measurement method. Three types of alpha track detectors based on passive radon ((222)Rn)-(220)Rn discriminative measurement technique were used: Raduet and Radopot detectors were used at NIRS, and four-leaf detectors were used at NYU. In this study, the authors evaluated (220)Rn concentration variation in terms of run for exposure, measurement method, and exposure chamber. The detectors were exposed to (220)Rn gas with approximately 15 kBq m(-3) during the period from 0.75 to 3 d. As a result, the variation of each measurement method among these exposure runs was comparable to or less than that for the two-filter method. Agreement between the standard measurement methods of NIRS and NYU was observed to be about 10%, as is the case with the passive detectors. The Raduet detector showed a large variation in the detection response between the NIRS and NYU chambers, which could be related to different traceability.

  4. 48 CFR 211.275-1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Documents 211.275-1 Definitions. Bulk commodities, case, palletized unit load, passive RFID tag, and radio frequency identification are defined in the clause at 252.211-7006, Passive Radio Frequency Identification...

  5. Passive millimeter-wave imaging for concealed article detection

    NASA Astrophysics Data System (ADS)

    Lovberg, John A.; Galliano, Joseph A., Jr.; Clark, Stuart E.

    1997-02-01

    Passive-millimeter-wave imaging (PMI) provides a powerful sensing tool for law enforcement, allowing an unobtrusive means for detecting concealed weapons, explosives, or contraband on persons or in baggage. Natural thermal emissions at millimeter wavelengths from bodies, guns, explosives, and other articles pass easily through clothing or other concealment materials, where they can be detected and converted into conventional 2-dimensional images. A new implementation of PMI has demonstrated a large-area, near- real-time staring capability for personnel inspection at standoff ranges of greater than 10 meters. In this form, PMI does not require operator cuing based on subjective 'profiles' of suspicious appearance or behaviors, which may otherwise be construed as violations of civil rights. To the contrary, PMI detects and images heat generated by any object with no predisposition as to its nature or function (e.g. race or gender of humans). As a totally passive imaging tool, it generates no radio-frequency or other radiation which might raise public health concerns. Specifics of the new PMI architecture are presented along with a host of imaging data representing the current state- of-the-art.

  6. Monoclonal antibody passive hemagglutination and capture enzyme-linked immunosorbent assays for direct detection and quantitation of F41 and K99 fimbrial antigens in enterotoxigenic Escherichia coli.

    PubMed Central

    Raybould, T J; Crouch, C F; Acres, S D

    1987-01-01

    Production of diarrhea in neonatal calves by enterotoxigenic Escherichia coli depends on its ability to attach to the epithelial cells of the intestine via surface adhesins called pili or fimbriae and to secrete enterotoxins. The most important of these fimbriae are designated K99 and F41. We produced and characterized a murine monoclonal antibody specific to F41. This monoclonal antibody and a K99-specific monoclonal antibody were used to develop sensitive and specific passive hemagglutination and capture enzyme-linked immunosorbent assays (ELISAs) for detection and quantitation of F41 and K99 antigens in E. coli cultures and culture supernatants. The capture ELISA systems exhibited excellent sensitivity and specificity, whereas the passive hemagglutination systems appeared to be oversensitive. The ability of the capture ELISAs to detect K99 and F41 fimbrial antigens in fecal specimens from calves was evaluated. Fimbrial antigens were detected in six of six specimens from scouring calves but not in four of four specimens from nonscouring calves. PMID:2880866

  7. Attentional Capacity Limits Gap Detection during Concurrent Sound Segregation.

    PubMed

    Leung, Ada W S; Jolicoeur, Pierre; Alain, Claude

    2015-11-01

    Detecting a brief silent interval (i.e., a gap) is more difficult when listeners perceive two concurrent sounds rather than one in a sound containing a mistuned harmonic in otherwise in-tune harmonics. This impairment in gap detection may reflect the interaction of low-level encoding or the division of attention between two sound objects, both of which could interfere with signal detection. To distinguish between these two alternatives, we compared ERPs during active and passive listening with complex harmonic tones that could include a gap, a mistuned harmonic, both features, or neither. During active listening, participants indicated whether they heard a gap irrespective of mistuning. During passive listening, participants watched a subtitled muted movie of their choice while the same sounds were presented. Gap detection was impaired when the complex sounds included a mistuned harmonic that popped out as a separate object. The ERP analysis revealed an early gap-related activity that was little affected by mistuning during the active or passive listening condition. However, during active listening, there was a marked decrease in the late positive wave that was thought to index attention and response-related processes. These results suggest that the limitation in detecting the gap is related to attentional processing, possibly divided attention induced by the concurrent sound objects, rather than deficits in preattentional sensory encoding.

  8. Spatio-temporal pattern of sylvatic rabies in the Sultanate of Oman, 2006-2010.

    PubMed

    Hussain, Muhammad Hammad; Ward, Michael P; Body, Mohammed; Al-Rawahi, Abdulmajeed; Wadir, Ali Awlad; Al-Habsi, Saif; Saqib, Muhammad; Ahmed, Mohammed Sayed; Almaawali, Mahir Gharib

    2013-07-01

    Rabies was first reported in the Sultanate of Oman is 1990. We analysed passive surveillance data (444 samples) collected and reported between 2006 and 2010. During this period, between 45 and 75% of samples submitted from suspect animals were subsequently confirmed (fluorescent antibody test, histopathology and reverse transcription PCR) as rabies cases. Overall, 63% of submitted samples were confirmed as rabies cases. The spatial distribution of species-specific cases were similar (centred in north-central Oman with a northeast-southwest distribution), although fox cases had a wider distribution and an east-west orientation. Clustering of cases was detected using interpolation, local spatial autocorrelation and scan statistical analysis. Several local government areas (wilayats) in north-central Oman were identified where higher than expected numbers of laboratory-confirmed rabies cases were reported. For fox rabies, more clusters (local spatial autocorrelation analysis) and a larger clustered area (scan statistical analysis) were detected. In Oman, monthly reports of fox rabies cases were highly correlated (rSP>0.5) with reports of camel, cattle, sheep and goat rabies. The best-fitting ARIMA model included a seasonality component. Fox rabies cases reported 6 months previously best explained rabies reported cases in other animal species. Despite likely reporting bias, results suggest that rabies exists as a sylvatic cycle of transmission in Oman and an opportunity still exists to prevent establishment of dog-mediated rabies. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Sensor Management for Tactical Surveillance Operations

    DTIC Science & Technology

    2007-11-01

    active and passive sonar for submarine and tor- pedo detection, and mine avoidance. [range, bearing] range 1.8 km to 55 km Active or Passive AN/SLQ-501...finding (DF) unit [bearing, classification] maximum range 1100 km Passive Cameras (day- light/ night- vision) ( video & still) Record optical and...infrared still images or motion video of events for near-real time assessment or long term analysis and archiving. Range is limited by the image resolution

  10. Remote monitoring of fish in small streams: A unified approach using PIT tags

    USGS Publications Warehouse

    Zydlewski, G.B.; Horton, G.; Dubreuil, T.; Letcher, B.; Casey, S.; Zydlewski, Joseph D.

    2006-01-01

    Accurate assessments of fish populations are often limited by re-observation or recapture events. Since the early 1990s, passive integrated transponders (PIT tags) have been used to understand the biology of many fish species. Until recently, PIT applications in small streams have been limited to physical recapture events. To maximize recapture probability, we constructed PIT antenna arrays in small streams to remotely detect individual fish. Experiences from two different laboratories (three case studies) allowed us to develop a unified approach to applying PIT technology for enhancing data assessments. Information on equipment, its installation, tag considerations, and array construction is provided. Theoretical and practical definitions are introduced to standardize metrics for assessing detection efficiency. We demonstrate how certain conditions (stream discharge, vibration, and ambient radio frequency noise) affect the detection efficiency and suggest that by monitoring these conditions, expectations of efficiency can be modified. We emphasize the importance of consistently estimating detection efficiency for fisheries applications.

  11. Avian Influenza Vaccination of Poultry and Passive Case Reporting, Egypt

    PubMed Central

    Grosbois, Vladimir; Jobre, Yilma; Saad, Ahmed; El Nabi, Amira Abd; Galal, Shereen; Kalifa, Mohamed; El Kader, Soheir Abd; Dauphin, Gwenaëlle; Roger, François; Lubroth, Juan; Peyre, Marisa

    2012-01-01

    We investigated the influence of a mass poultry vaccination campaign on passive surveillance of highly pathogenic avian influenza subtype (H5N1) outbreaks among poultry in Egypt. Passive reporting dropped during the campaign, although probability of infection remained unchanged. Future poultry vaccination campaigns should consider this negative impact on reporting for adapting surveillance strategies. PMID:23171740

  12. Using Ozone To Clean and Passivate Oxygen-Handling Hardware

    NASA Technical Reports Server (NTRS)

    Torrance, Paul; Biesinger, Paul

    2009-01-01

    A proposed method of cleaning, passivating, and verifying the cleanliness of oxygen-handling hardware would extend the established art of cleaning by use of ozone. As used here, "cleaning" signifies ridding all exposed surfaces of combustible (in particular, carbon-based) contaminants. The method calls for exposing the surfaces of the hardware to ozone while monitoring the ozone effluent for carbon dioxide. The ozone would passivate the hardware while oxidizing carbon-based residues, converting the carbon in them to carbon dioxide. The exposure to ozone would be continued until no more carbon dioxide was detected, signifying that cleaning and passivation were complete.

  13. Rural health centres, communities and malaria case detection in Zambia using mobile telephones: a means to detect potential reservoirs of infection in unstable transmission conditions.

    PubMed

    Kamanga, Aniset; Moono, Petros; Stresman, Gillian; Mharakurwa, Sungano; Shiff, Clive

    2010-04-15

    Effective malaria control depends on timely acquisition of information on new cases, their location and their frequency so as to deploy supplies, plan interventions or focus attention on specific locations appropriately to intervene and prevent an upsurge in transmission. The process is known as active case detection, but because the information is time sensitive, it is difficult to carry out. In Zambia, the rural health services are operating effectively and for the most part are provided with adequate supplies of rapid diagnostic tests (RDT) as well as effective drugs for the diagnosis and treatment of malaria. The tests are administered to all prior to treatment and appropriate records are kept. Data are obtained in a timely manner and distribution of this information is important for the effective management of malaria control operations. The work reported here involves combining the process of positive diagnoses in rural health centres (passive case detection) to help detect potential outbreaks of malaria and target interventions to foci where parasite reservoirs are likely to occur. Twelve rural health centres in the Choma and Namwala Districts were recruited to send weekly information of rapid malaria tests used and number of positive diagnoses to the Malaria Institute at Macha using mobile telephone SMS. Data were entered in excel, expressed as number of cases per rural health centre and distributed weekly to interested parties. These data from each of the health centres which were mapped using geographical positioning system (GPS) coordinates were used in a time sensitive manner to plot the patterns of malaria case detection in the vicinity of each location. The data were passed on to the appropriate authorities. The seasonal pattern of malaria transmission associated with local ecological conditions can be seen in the distribution of cases diagnosed. Adequate supplies of RDT are essential in health centres and the system can be expanded throughout the country to support strategic targeting of interventions by the National Malaria Control Programme. Participation by the health centre staff was excellent.

  14. Passive fire building protection system evaluation (case study: millennium ict centre)

    NASA Astrophysics Data System (ADS)

    Rahman, Vinky; Stephanie

    2018-03-01

    Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper

  15. [Effects of active and passive smoking during pregnancy on the development of gestational hypertension and fetal hypotrophy].

    PubMed

    Krzyścin, Mariola; Dera-Szymanowska, Anna; Napierała, Marta; Chuchracki, Marek; Markwitz, Wiesław; Breborowicz, Grzegorz H; Florek, Ewa

    2015-01-01

    In prenatal life the fetus can be exposed to more incentires which affect the mother. In case of both active and passive smoking by pregnant women many pernicious substances contained in tobacco smoke can influence the foetus. The components of tobacco smoke can contribute to various antenatal complications. The aim of present work was to assess if the data given by the patient in anonymous questionnaire go along with the real exposure to components of smoke assessed on the basis of concentration of nicotine metabolite- cotinine in mother's serum and next to assess the risk of development of gestational hypertension and hypotrophy. The biological material was extracted with means of liquid-liquid technique and next we performed laboratory determinations with means of liquid chro- matography with sectrophotometric detection, in which norephedrine is used as inner sample. The study was carried out on 106 women in perinatal period who give birth from single, full term pregnancy. On the basis of questionnaire data considering the concentration of cotinine, the patients were divided into three groups: I group--active smokers (n = 27), II group--passive smokers (n = 32), III group--not exposed to tobacco smoke (n = 41). The average concentration of cotinine in blood serum in the first group was 129.6 ng/ml, second group--5.1 ng/ ml, but in all patients from the control group the concentration of cotinine was below the detection level. Gestational hypertension was diagnosed in 17 women (16%) and hypotrophy of the foetus was diagnosed in 15 patients (14%). Tobacco smoking didn't influence the development of gestational hypertension and hypotrophy showered it is more often observed in women exposed to components of tobacco smoke during pregnancy.

  16. FT-IR standoff detection of thermally excited emissions of trinitrotoluene (TNT) deposited on aluminum substrates.

    PubMed

    Castro-Suarez, John R; Pacheco-Londoño, Leonardo C; Vélez-Reyes, Miguel; Diem, Max; Tague, Thomas J; Hernandez-Rivera, Samuel P

    2013-02-01

    A standoff detection system was assembled by coupling a reflecting telescope to a Fourier transform infrared spectrometer equipped with a cryo-cooled mercury cadmium telluride detector and used for detection of solid-phase samples deposited on substrates. Samples of highly energetic materials were deposited on aluminum substrates and detected at several collector-target distances by performing passive-mode, remote, infrared detection measurements on the heated analytes. Aluminum plates were used as support material, and 2,4,6-Trinitrotoluene (TNT) was used as the target. For standoff detection experiments, the samples were placed at different distances (4 to 55 m). Several target surface temperatures were investigated. Partial least squares regression analysis was applied to the analysis of the intensities of the spectra obtained. Overall, standoff detection in passive mode was useful for quantifying TNT deposited on the aluminum plates with high confidence up to target-collector distances of 55 m.

  17. Detection of person borne IEDs using multiple cooperative sensors

    NASA Astrophysics Data System (ADS)

    MacIntosh, Scott; Deming, Ross; Hansen, Thorkild; Kishan, Neel; Tang, Ling; Shea, Jing; Lang, Stephen

    2011-06-01

    The use of multiple cooperative sensors for the detection of person borne IEDs is investigated. The purpose of the effort is to evaluate the performance benefits of adding multiple sensor data streams into an aided threat detection algorithm, and a quantitative analysis of which sensor data combinations improve overall detection performance. Testing includes both mannequins and human subjects with simulated suicide bomb devices of various configurations, materials, sizes and metal content. Aided threat recognition algorithms are being developed to test detection performance of individual sensors against combined fused sensors inputs. Sensors investigated include active and passive millimeter wave imaging systems, passive infrared, 3-D profiling sensors and acoustic imaging. The paper describes the experimental set-up and outlines the methodology behind a decision fusion algorithm-based on the concept of a "body model".

  18. In situ-synthesized cadmium sulfide nanowire photosensor with a parylene passivation layer for chemiluminescent immunoassays.

    PubMed

    Im, Ju-Hee; Kim, Hong-Rae; An, Byoung-Gi; Chang, Young Wook; Kang, Min-Jung; Lee, Tae-Geol; Son, Jin Gyeng; Park, Jae-Gwan; Pyun, Jae-Chul

    2017-06-15

    The direct in situ synthesis of cadmium sulfide (CdS) nanowires (NWs) was presented by direct synthesis of CdS NWs on the gold surface of an interdigitated electrode (IDE). In this work, we investigated the effect of a strong oxidant on the surfaces of the CdS NWs using X-ray photoelectron spectroscopy, transmission electron microscopy, and time-of-flight secondary ion mass spectrometry. We also fabricated a parylene-C film as a surface passivation layer for in situ-synthesized CdS NW photosensors and investigated the influence of the parylene-C passivation layer on the photoresponse during the coating of parylene-C under vacuum using a quartz crystal microbalance and a photoanalyzer. Finally, we used the in situ-synthesized CdS NW photosensor with the parylene-C passivation layer to detect the chemiluminescence of horseradish peroxidase and luminol and applied it to medical detection of carcinoembryonic antigen. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Gas House Autonomous System Monitoring

    NASA Technical Reports Server (NTRS)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  20. Malaria in tree crop plantations in south-eastern and western provinces of Thailand.

    PubMed

    Singhasivanon, P; Thimasarn, K; Yimsamran, S; Linthicum, K; Nualchawee, K; Dawreang, D; Kongrod, S; Premmanisakul, N; Maneeboonyang, W; Salazar, N

    1999-09-01

    During the past three decades almost half of the existing natural tropical forests in Thailand were destroyed and replaced by cash crops, rubber, coffee, fruit orchards (durian, rambutan, mangosteen) and other commercial plantations. In order to determine the proportion of malaria cases contracted from such commercial plantations, an epidemiological study was conducted between June 1996 to May 1997 in two districts, one in Pong Nam Ron, located in a south-eastern province near the Cambodian border and another in Sai Yok, in a western province along the Myanmar border. Data were collected by passive case detection from patients attending the existing malaria clinics and active case detection by monthly malariometric survey in selected villages. All malaria cases were thoroughly investigated and classified according to exposure to different ecotypes prior to onset of malaria symptoms in the preceding two weeks. Malaria cases acquired from commercial plantations accounted for 35.2% and 11.2% in Pong Nam Ron and in Sai Yok districts respectively. In such plantations, most of the malaria cases were contracted from fruit orchards and to a lesser extent from rubber and teak plantations. From this study it is evident that commercial plantations provide a significant site of malaria transmission in addition to the forest and foothills areas in Southeast Asia where efficient vectors such as An. dirus and An. minimus are prevalent and have adapted to such changed ecosystems.

  1. Cost-effectiveness of active case-finding of household contacts of pulmonary tuberculosis patients in a low HIV, tuberculosis-endemic urban area of Lima, Peru.

    PubMed

    Shah, L; Rojas, M; Mori, O; Zamudio, C; Kaufman, J S; Otero, L; Gotuzzo, E; Seas, C; Brewer, T F

    2017-04-01

    We compared the cost-effectiveness (CE) of an active case-finding (ACF) programme for household contacts of tuberculosis (TB) cases enrolled in first-line treatment to routine passive case-finding (PCF) within an established national TB programme in Peru. Decision analysis was used to model detection of TB in household contacts through: (1) self-report of symptomatic cases for evaluation (PCF), (2) a provider-initiated ACF programme, (3) addition of an Xpert MTB/RIF diagnostic test for a single sputum sample from household contacts, and (4) all strategies combined. CE was calculated as the incremental cost-effectiveness ratio (ICER) in terms of US dollars per disability-adjusted life years (DALYs) averted. Compared to PCF alone, ACF for household contacts resulted in an ICER of $2155 per DALY averted. The addition of the Xpert MTB/RIF diagnostic test resulted in an ICER of $3275 per DALY averted within a PCF programme and $3399 per DALY averted when an ACF programme was included. Provider-initiated ACF of household contacts in an urban setting of Lima, Peru can be highly cost-effective, even including costs to seek out contacts and perform an Xpert/MTB RIF test. ACF including Xpert MTB/RIF was not cost-effective if TB cases detected had high rates of default from treatment or poor outcomes.

  2. Speech characteristics after articulation therapy in children with cleft palate and velopharyngeal dysfunction - A single case experimental design.

    PubMed

    Derakhshandeh, Fatemeh; Nikmaram, Mohammadreza; Hosseinabad, Hedieh Hashemi; Memarzadeh, Mehrdad; Taheri, Masoud; Omrani, Mohammadreza; Jalaie, Shohreh; Bijankhan, Mahmood; Sell, Debbie

    2016-07-01

    The aim of this study was to investigate the impact of an intensive 10-week course of articulation therapy on articulation errors in cleft lip and palate patients who have Velopharyngeal Insufficiency (VPI), non-oral and passive cleft speech characteristics. Five children with cleft palate (+/-cleft lip) with VPI and non-oral and passive cleft speech characteristics underwent 40 intensive articulation therapies over 10 weeks in a single case experimental design. The percentage of non-oral CSCs (NCSCs), passive CSCs (PCSCs), stimulable consonants (SC), correct consonants in word imitation (CCI), and correct consonants in picture naming (CCN) were captured at baseline, during intervention and in follow up phases. Visual analysis and two effect size indexes of Percentage of Nonoverlapping Data and Percentage of Improvement Rate Difference were analyzed. Articulation therapy resulted in visible decrease in NCSCs for all 5 participants across the intervention phases. Intervention was effective in changing percentage of passive CSCs in two different ways; it reduced the PCSCs in three cases and resulted in an increase in PCSCs in the other two cases. This was interpreted as intervention having changed the non-oral CSCs to consonants produced within the oral cavity but with passive characteristics affecting manner of production including weakness, nasalized plosives and nasal realizations of plosives and fricatives. Percent SC increased throughout the intervention period in all five patients. All participants demonstrated an increase in percentage of CCI and CCN suggesting an increase in the consonant inventory. Follow-up data showed that all the subjects were able to maintain their ability to articulate learned phonemes correctly even after a 4-week break from intervention. This single case experimental study supports the hypothesis that speech intervention in patients with VPI can result in an improvement in oral placements and passive CSCs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Passive micromixer for luminol-peroxide chemiluminescence detection.

    PubMed

    Lok, Khoi Seng; Kwok, Yien Chian; Nguyen, Nam-Trung

    2011-06-21

    This paper reports a microchip with an integrated passive micromixer based on chaotic advection. The micromixer with staggered herringbone structures was used for luminol-peroxide chemiluminescence detection. The micromixer was examined to assess its suitability for chemiluminescence reaction. The relationship between the flow rate and the location of maximum chemiluminescence intensity was investigated. The light intensity was detected using an optical fiber attached along the mixing channel and a photon detector. A linear correlation between chemiluminescence intensity and the concentration of cobalt(ii) ions or hydrogen peroxide was observed. This microchip has a potential application in environmental monitoring for industries involved in heavy metals and in medical diagnostics.

  4. Threat detection in desert environment with passive millimeter-wave sensor

    NASA Astrophysics Data System (ADS)

    Wilson, John P.; Schuetz, Christopher A.; Martin, Richard D.; Dillon, Thomas E.; Murakowski, Maciej; Prather, Dennis W.

    2011-06-01

    A new technique for improvised explosive device (IED) creation uses an explosive device buried in foam and covered in a layer of dirt. These devices are difficult to detect visually, however, their material characteristics make them detectable by passive millimeter-wave (pmmW) sensors. Results are presented from a test using a mock IED and an outdoor set-up consisting of two mock IEDs on a dirt background. The results show that the mock IEDs produces a millimeter-wave signature which is distinguishable from the background surrounding the mock IEDs. Simulations based on the measured data are presented and a design for a future vehicle mounted sensor is shown.

  5. A family of asymptotically stable control laws for flexible robots based on a passivity approach

    NASA Technical Reports Server (NTRS)

    Lanari, Leonardo; Wen, John T.

    1991-01-01

    A general family of asymptotically stabilizing control laws is introduced for a class of nonlinear Hamiltonian systems. The inherent passivity property of this class of systems and the Passivity Theorem are used to show the closed-loop input/output stability which is then related to the internal state space stability through the stabilizability and detectability condition. Applications of these results include fully actuated robots, flexible joint robots, and robots with link flexibility.

  6. Performance of passive samplers for monitoring estuarine water column concentrations: 2. Emerging contaminants.

    PubMed

    Perron, Monique M; Burgess, Robert M; Suuberg, Eric M; Cantwell, Mark G; Pennell, Kelly G

    2013-10-01

    Measuring dissolved concentrations of emerging contaminants, such as polybrominated diphenyl ethers (PBDEs) and triclosan, can be challenging due to their physicochemical properties resulting in low aqueous solubilities and association with particles. Passive sampling methods have been applied to assess dissolved concentrations in water and sediments primarily for legacy contaminants. Although the technology is applicable to some emerging contaminants, the use of passive samplers with emerging contaminants is limited. In the present study, the performance of 3 common passive samplers was evaluated for sampling PBDEs and triclosan. Passive sampling polymers included low-density polyethylene (PE) and polyoxymethylene (POM) sheets, and polydimethylsiloxane (PDMS)-coated solid-phase microextraction (SPME) fibers. Dissolved concentrations were calculated using measured sampler concentrations and laboratory-derived partition coefficients. Dissolved tri-, tetra-, and pentabrominated PBDE congeners were detected at several of the study sites at very low pg/L concentrations using PE and POM. Calculated dissolved water concentrations of triclosan ranged from 1.7 ng/L to 18 ng/L for POM and 8.8 ng/L to 13 ng/L for PE using performance reference compound equilibrium adjustments. Concentrations in SPME were not reported due to lack of detectable chemical in the PDMS polymer deployed. Although both PE and POM were found to effectively accumulate emerging contaminants from the water column, further research is needed to determine their utility as passive sampling devices for emerging contaminants. © 2013 SETAC.

  7. Performance characterisation of a passive cavitation detector optimised for subharmonic periodic shock waves from acoustic cavitation in MHz and sub-MHz ultrasound.

    PubMed

    Johansen, Kristoffer; Song, Jae Hee; Prentice, Paul

    2018-05-01

    We describe the design, construction and characterisation of a broadband passive cavitation detector, with the specific aim of detecting low frequency components of periodic shock waves, with high sensitivity. A finite element model is used to guide selection of matching and backing layers for the shock wave passive cavitation detector (swPCD), and the performance is evaluated against a commercially available device. Validation of the model, and characterisation of the swPCD is achieved through experimental detection of laser-plasma bubble collapse shock waves. The final swPCD design is 20 dB more sensitive to the subharmonic component, from acoustic cavitation driven at 220 kHz, than the comparable commercial device. This work may be significant for monitoring cavitation in medical applications, where sensitive detection is critical, and higher frequencies are more readily absorbed by tissue. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Spent fuel measurements. passive neutron albedo reactivity (PNAR) and photon signatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eigenbrodt, Julia; Menlove, Howard Olsen

    2016-03-29

    The International Atomic Energy Agency’s (IAEA) safeguards technical objective is the timely detection of a diversion of a significant quantity of nuclear material from peaceful activities to the manufacture of nuclear weapons or of other nuclear explosive devices or for purposes unknown, and deterrence of such diversion by the risk of early detection. An important IAEA task towards meeting this objective is the ability to accurately and reliably measure spent nuclear fuel (SNF) to verify reactor operating parameters and verify that the fuel has not been removed from reactors or SNF storage facilities. This dissertation analyzes a method to improvemore » the state-of-the-art of nuclear material safeguards measurements using two combined measurement techniques: passive neutron albedo reactivity (PNAR) and passive spectral photon measurements.« less

  9. AMS of 93Zr: Passive absorber versus gas-filled magnet

    NASA Astrophysics Data System (ADS)

    Hain, Karin; Deneva, Boyana; Faestermann, Thomas; Fimiani, Leticia; Gómez-Guzmán, José Manuel; Koll, Dominik; Korschinek, Gunther; Ludwig, Peter; Sergeyeva, Victoria; Thiollay, Nicolas

    2018-05-01

    Two different isobar separation techniques were tested for the detection of the long-lived fission product 93Zr (T1/2 = 1.64 · 106 a) using Accelerator Mass Spectrometry (AMS), i.e. a passive absorber and a gas-filled magnet, respectively. Both techniques were used in combination with a Time-of-Flight path for the identification of the stable neighboring isotopes 92Zr and 94Zr. The passive absorber was represented by a stack of silicon nitride foils for high flexibility regarding the thickness for optimal isobar separation. Ion beams with a large variety of energies, between 80 and 180 MeV, were provided for this experiment by the tandem accelerator at the Maier-Leibnitz Laboratory in Garching, Germany. With these beams, the stopping powers of 93Zr and 93Nb as a function of energy were determined experimentally and compared to the results obtained with the simulation program SRIM. Considerable discrepancies regarding the energy dependence of the two stopping power curves relative to each other were found. The lowest detection limit for 93Zr achieved with the passive absorber setup was 93Zr/Zr = 1 · 10-10. In comparison, by optimizing the gas-filled magnet set-up, 93Nb was suppressed by around six orders of magnitude and a detection limit of 93Zr/Zr = 5 · 10-11 was obtained. To our knowledge, these results represent the lowest detection limit achieved for 93Zr until now.

  10. Wavelet Fusion for Concealed Object Detection Using Passive Millimeter Wave Sequence Images

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Pang, L.; Liu, H.; Xu, X.

    2018-04-01

    PMMW imaging system can create interpretable imagery on the objects concealed under clothing, which gives the great advantage to the security check system. Paper addresses wavelet fusion to detect concealed objects using passive millimeter wave (PMMW) sequence images. According to PMMW real-time imager acquired image characteristics and storage methods firstly, using the sum of squared difference (SSD) as the image-related parameters to screen the sequence images. Secondly, the selected images are optimized using wavelet fusion algorithm. Finally, the concealed objects are detected by mean filter, threshold segmentation and edge detection. The experimental results show that this method improves the detection effect of concealed objects by selecting the most relevant images from PMMW sequence images and using wavelet fusion to enhance the information of the concealed objects. The method can be effectively applied to human body concealed object detection in millimeter wave video.

  11. West Nile virus in north-eastern Italy, 2011: entomological and equine IgM-based surveillance to detect active virus circulation.

    PubMed

    Mulatti, Paolo; Bonfanti, Lebana; Capelli, Gioia; Capello, Katia; Lorenzetto, Monica; Terregino, Calogero; Monaco, Federica; Ferri, Gaetana; Marangon, Stefano

    2013-08-01

    Since 2008, West Nile Virus (WNV) has expanded its range in several Italian regions, and its yearly recurrence suggests the virus may have become endemic in some areas. In 2011, a new plan based also on the detection of IgM antibodies was implemented in the north-eastern Italian regions of Veneto and Friuli Venezia Giulia, aiming to early detect WNV infections in areas where the virus had already circulated during the previous summers, and in adjacent zones. From July to November 2011, 1880 sera from 521 equine premises were screened by a commercial IgM capture ELISA. Mosquitoes were captured by CDC-CO2 traps at 61 locations in the two regions. Collected mosquitoes were identified, pooled by species/date/location and examined by real-time RT-PCR and sequencing. Passive surveillance was carried out on clinically affected horses and non-migratory wild birds found dead. IgM sero-positive equines were detected in 19 holdings, five in the area with WNV circulation (AWC) and 14 in the surveillance area (SA); 10 more horse premises tested positive to further serological controls within 4 km of the positive holdings. A total of 85,398 mosquitoes of 15 species were collected and 2732 pools examined. Five Culex pipiens pools tested positive for the presence of WNV. Passive surveillance on non-migratory wild birds allowed detection of the virus only in one found dead collared dove (Streptopelia decaocto), of 82 birds sampled. The WNV belonged to the lineage 2, which had been isolated for the first time in Italy earlier in 2011. By the first week of October, nine human cases had been confirmed in the same area. The implementation of a protocol combining IgM screening of horses with surveillance on mosquito vectors proved to be valuable for early detecting WNV circulation. © 2012 Blackwell Verlag GmbH.

  12. Comparison of human and algorithmic target detection in passive infrared imagery

    NASA Astrophysics Data System (ADS)

    Weber, Bruce A.; Hutchinson, Meredith

    2003-09-01

    We have designed an experiment that compares the performance of human observers and a scale-insensitive target detection algorithm that uses pixel level information for the detection of ground targets in passive infrared imagery. The test database contains targets near clutter whose detectability ranged from easy to very difficult. Results indicate that human observers detect more "easy-to-detect" targets, and with far fewer false alarms, than the algorithm. For "difficult-to-detect" targets, human and algorithm detection rates are considerably degraded, and algorithm false alarms excessive. Analysis of detections as a function of observer confidence shows that algorithm confidence attribution does not correspond to human attribution, and does not adequately correlate with correct detections. The best target detection score for any human observer was 84%, as compared to 55% for the algorithm for the same false alarm rate. At 81%, the maximum detection score for the algorithm, the same human observer had 6 false alarms per frame as compared to 29 for the algorithm. Detector ROC curves and observer-confidence analysis benchmarks the algorithm and provides insights into algorithm deficiencies and possible paths to improvement.

  13. Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mule, S.J.; Lomax, P.; Gross, S.J.

    Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation.

  14. Passive tick surveillance, dog seropositivity, and incidence of human Lyme disease

    USGS Publications Warehouse

    Johnson, Jaree L.; Ginsberg, Howard S.; Zhioua, Elyes; Whitworth, Ulysses G.; Markowski, Daniel; Hyland, Kerwin E.; Hu, Renjie

    2004-01-01

    Data on nymphal Ixodes scapularis ticks submitted by the public to the University of Rhode Island Tick Research Laboratory for testing from 1991 to 2000 were compared with human case data from the Rhode Island Department of Health to determine the efficacy of passive tick surveillance at assessing human risk of Lyme disease. Numbers of ticks submitted were highly correlated with human cases by county (r = 0.998, n = 5 counties) and by town (r = 0.916, n = 37 towns), as were the numbers of positive ticks submitted (r = 0.989 by county, r = 0.787 by town). Human cases were correlated with ticks submitted by town each year, and with positive ticks in all but 2 years. Thus, passive tick surveillance effectively assessed geographical risk of human Lyme disease. In contrast, tick submissions through time were not correlated with human cases from year to year. Dog seropositivity was significantly correlated with human cases by county in both years tested, but by town in only one of two years. Numbers of ticks submitted were correlated with dog seropositivity by county but not by town, apparently because of high variability among towns with small sample sizes. Our results suggest that passive tick surveillance, using ticks submitted by the public for Lyme spirochete testing, can be used to assess the geographical distribution of Lyme disease risk, but cannot reliably predict Lyme incidence from year to year.

  15. Passive in-vehicle driver breath alcohol detection using advanced sensor signal acquisition and fusion.

    PubMed

    Ljungblad, Jonas; Hök, Bertil; Allalou, Amin; Pettersson, Håkan

    2017-05-29

    The research objective of the present investigation is to demonstrate the present status of passive in-vehicle driver breath alcohol detection and highlight the necessary conditions for large-scale implementation of such a system. Completely passive detection has remained a challenge mainly because of the requirements on signal resolution combined with the constraints of vehicle integration. The work is part of the Driver Alcohol Detection System for Safety (DADSS) program aiming at massive deployment of alcohol sensing systems that could potentially save thousands of American lives annually. The work reported here builds on earlier investigations, in which it has been shown that detection of alcohol vapor in the proximity of a human subject may be traced to that subject by means of simultaneous recording of carbon dioxide (CO 2 ) at the same location. Sensors based on infrared spectroscopy were developed to detect and quantify low concentrations of alcohol and CO 2 . In the present investigation, alcohol and CO 2 were recorded at various locations in a vehicle cabin while human subjects were performing normal in-step procedures and driving preparations. A video camera directed to the driver position was recording images of the driver's upper body parts, including the face, and the images were analyzed with respect to features of significance to the breathing behavior and breath detection, such as mouth opening and head direction. Improvement of the sensor system with respect to signal resolution including algorithm and software development, and fusion of the sensor and camera signals was successfully implemented and tested before starting the human study. In addition, experimental tests and simulations were performed with the purpose of connecting human subject data with repeatable experimental conditions. The results include occurrence statistics of detected breaths by signal peaks of CO 2 and alcohol. From the statistical data, the accuracy of breath alcohol estimation and timing related to initial driver routines (door opening, taking a seat, door closure, buckling up, etc.) can be estimated. The investigation confirmed the feasibility of passive driver breath alcohol detection using our present system. Trade-offs between timing and sensor signal resolution requirements will become critical. Further improvement of sensor resolution and system ruggedness is required before the results can be industrialized. It is concluded that a further important step toward completely passive detection of driver breath alcohol has been taken. If required, the sniffer function with alcohol detection capability can be combined with a subsequent highly accurate breath test to confirm the driver's legal status using the same sensor device. The study is relevant to crash avoidance, in particular driver monitoring systems and driver-vehicle interface design.

  16. Active Detection for Exposing Intelligent Attacks in Control Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weerakkody, Sean; Ozel, Omur; Griffioen, Paul

    In this paper, we consider approaches for detecting integrity attacks carried out by intelligent and resourceful adversaries in control systems. Passive detection techniques are often incorporated to identify malicious behavior. Here, the defender utilizes finely-tuned algorithms to process information and make a binary decision, whether the system is healthy or under attack. We demonstrate that passive detection can be ineffective against adversaries with model knowledge and access to a set of input/output channels. We then propose active detection as a tool to detect attacks. In active detection, the defender leverages degrees of freedom he has in the system to detectmore » the adversary. Specifically, the defender will introduce a physical secret kept hidden from the adversary, which can be utilized to authenticate the dynamics. In this regard, we carefully review two approaches for active detection: physical watermarking at the control input, and a moving target approach for generating system dynamics. We examine practical considerations for implementing these technologies and discuss future research directions.« less

  17. Passivation of long-wave infrared InAs/GaSb strained layer superlattice detectors

    NASA Astrophysics Data System (ADS)

    Plis, E.; Kutty, M. N.; Myers, S.; Kim, H. S.; Gautam, N.; Dawson, L. R.; Krishna, S.

    2011-05-01

    We have investigated various passivation techniques for type-II InAs/GaSb strained layer superlattice (SLS) detectors with p-i-n and PbIbN designs with a 100%-cut-off wavelength of ˜12 μm at 77 K. The passivation schemes include dielectric deposition (silicon nitride (SiN x), silicon dioxide (SiO 2), photoresist (SU-8)), chalcogenide treatments (zinc sulfide (ZnS), ammonium sulfide [(NH 4) 2S]), and electrochemical sulphur deposition. [(NH 4) 2S] passivation and electrochemical sulphur passivation (ECP) showed the better performances, improving the dark current density by factors of 200 and 25 (p-i-n detector) and ˜3 and 54 (PbIbN detector), respectively ( T = 77 K, -0.1 V of applied bias). The specific detectivity D* was improved by a factor of 2 and by an order of magnitude for (NH 4) 2S and ECP passivated PbIbN detectors, respectively.

  18. Structure for implementation of back-illuminated CMOS or CCD imagers

    NASA Technical Reports Server (NTRS)

    Pain, Bedabrata (Inventor); Cunningham, Thomas J. (Inventor)

    2009-01-01

    A structure for implementation of back-illuminated CMOS or CCD imagers. An epitaxial silicon layer is connected with a passivation layer, acting as a junction anode. The epitaxial silicon layer converts light passing through the passivation layer and collected by the imaging structure to photoelectrons. A semiconductor well is also provided, located opposite the passivation layer with respect to the epitaxial silicon layer, acting as a junction cathode. Prior to detection, light does not pass through a dielectric separating interconnection metal layers.

  19. Meals on Wheels? A Decade of Megafaunal Visual and Acoustic Observations from Offshore Oil & Gas Rigs and Platforms in the North and Irish Seas.

    PubMed

    Todd, Victoria Louise Georgia; Warley, Jane Clare; Todd, Ian Boyer

    2016-01-01

    A decade of visual and acoustic detections of marine megafauna around offshore Oil & Gas (O&G) installations in the North and Irish Seas are presented. Marine megafauna activity was monitored visually and acoustically by Joint Nature Conservation Committee (JNCC) qualified and experienced Marine Mammal Observers (MMO) and Passive Acoustic Monitoring (PAM) Operators respectively, with real-time towed PAM in combination with industry standard software, PAMGuard. Monitoring was performed during routine O&G industrial operations for underwater noise mitigation purposes, and to ensure adherence to regulatory guidelines. Incidental sightings by off-effort MMOs and installation crew were also reported. Visual and acoustic monitoring spanned 55 non-consecutive days between 2004 and 2014. A total of 47 marine mammal sightings were recorded by MMOs on dedicated watch, and 10 incidental sightings of marine megafauna were reported over 10 years. Species included: harbour porpoise (Phocoena phocoena), Atlantic white-sided dolphin (Lagenorhynchus acutus), white beaked dolphin (Lagenorhynchus albirostris), common dolphin (Delphinus delphis), minke whale (Balaenoptera acutorostrata), common seal (Phoca vitulina), grey seal (Halichoerus grypus) and, basking shark (Cetorhinus maximus). Passive Acoustic Monitoring was conducted on two occasions in 2014; 160 PAM hours over 12 days recorded a total of 308 individual clicks identified as harbour porpoises. These appear to be the first such acoustic detections obtained from a North Sea drilling rig whilst using a typically configured hydrophone array designed for towing in combination with real-time PAMGuard software. This study provides evidence that marine megafauna are present around mobile and stationary offshore O&G installations during routine operational activities. On this basis, Environmental Impact Assessments (EIAs) for decommissioning O&G platforms should be carried-out on a case-by-case basis, and must include provisions for hitherto overlooked marine megafauna.

  20. Passive seismic monitoring of natural and induced earthquakes: case studies, future directions and socio-economic relevance

    USGS Publications Warehouse

    Bohnhoff, Marco; Dresen, Georg; Ellsworth, William L.; Ito, Hisao; Cloetingh, Sierd; Negendank, Jörg

    2010-01-01

    An important discovery in crustal mechanics has been that the Earth’s crust is commonly stressed close to failure, even in tectonically quiet areas. As a result, small natural or man-made perturbations to the local stress field may trigger earthquakes. To understand these processes, Passive Seismic Monitoring (PSM) with seismometer arrays is a widely used technique that has been successfully applied to study seismicity at different magnitude levels ranging from acoustic emissions generated in the laboratory under controlled conditions, to seismicity induced by hydraulic stimulations in geological reservoirs, and up to great earthquakes occurring along plate boundaries. In all these environments the appropriate deployment of seismic sensors, i.e., directly on the rock sample, at the earth’s surface or in boreholes close to the seismic sources allows for the detection and location of brittle failure processes at sufficiently low magnitude-detection threshold and with adequate spatial resolution for further analysis. One principal aim is to develop an improved understanding of the physical processes occurring at the seismic source and their relationship to the host geologic environment. In this paper we review selected case studies and future directions of PSM efforts across a wide range of scales and environments. These include induced failure within small rock samples, hydrocarbon reservoirs, and natural seismicity at convergent and transform plate boundaries. Each example represents a milestone with regard to bridging the gap between laboratory-scale experiments under controlled boundary conditions and large-scale field studies. The common motivation for all studies is to refine the understanding of how earthquakes nucleate, how they proceed and how they interact in space and time. This is of special relevance at the larger end of the magnitude scale, i.e., for large devastating earthquakes due to their severe socio-economic impact.

  1. Some signals cannot wait: effects of a national campaign on early detection of cancer among Dutch adults (>55 years).

    PubMed

    Reubsaet, Astrid; van Osch, Liesbeth A D M; de Vries, Hein; de Coul, Maaike R Op; Lechner, Lilian

    2009-10-01

    The present study examined the effects of the campaign "early detection of cancer" on knowledge, attitudes, awareness, and intention to perform passive detection and timely seeking medical help. Further, the campaign was evaluated on recall and recognition and the various campaign components were evaluated. A longitudinal study using a Solomon four-group design among 784 Dutch adults aged 55 years and older was conducted. Data was gathered by means of telephone interviews. The results showed moderate levels of campaign awareness. After the campaign, solely respondents who received a pre-test questionnaire and were aware of the campaign had significant higher cancer knowledge levels regarding passive detection. Respondents who were only aware of the campaign were significantly more willing to perform passive detection behavior and to timely seek medical help in the future. Further, they were more aware that paying attention to cancer warning signs can lead to early detection of cancer. It can be concluded that solely the combination of the pre-test questionnaire and exposure to the campaign had a significant positive impact on respondents' cancer knowledge levels. The effects of the campaign on intention and awareness are indistinct and could be a consequence of (the results of) a self-selection bias. It seems that the dose, frequency, and duration of the campaign should be increased in order to substantiate the effects of the campaign.

  2. A non-imaging polarized terahertz passive system for detecting and identifying concealed explosives

    NASA Astrophysics Data System (ADS)

    Karam, Mostafa A.; Meyer, Doug

    2011-06-01

    Existing terahertz THz systems for detecting concealed explosives are not capable of identifying explosive type which leads to higher false alarm rates. Moreover, some of those systems are imaging systems that invade personal privacy, and require more processing and computational resources. Other systems have no polarization preference which makes them incapable of capturing the geometric features of an explosive. In this study a non-imaging polarized THz passive system for detecting and identifying concealed explosives overcoming the forgoing shortcomings is developed. The system employs a polarized passive THz sensor in acquiring emitted data from a scene that may have concealed explosives. The acquired data are decomposed into their natural resonance frequencies, and the number of those frequencies is used as criteria in detecting the explosive presence. If the presence of an explosive is confirmed, a set of physically based retrieval algorithms is used in extracting the explosive dielectric constant/refractive index value from natural resonance frequencies and amplitudes of associated signals. Comparing the refractive index value against a database of refractive indexes of known explosives identifies the explosive type. As an application, a system having a dual polarized radiometer operating within the frequency band of 0.62- 0.82 THz is presented and used in detecting and identifying person borne C-4 explosive concealed under a cotton garment. The system showed higher efficiencies in detecting and identifying the explosive.

  3. Digital filtering implementations for the detection of broad spectral features by direct analysis of passive Fourier transform infrared interferograms.

    PubMed

    Tarumi, Toshiyasu; Small, Gary W; Combs, Roger J; Kroutil, Robert T

    2004-04-01

    Finite impulse response (FIR) filters and finite impulse response matrix (FIRM) filters are evaluated for use in the detection of volatile organic compounds with wide spectral bands by direct analysis of interferogram data obtained from passive Fourier transform infrared (FT-IR) measurements. Short segments of filtered interferogram points are classified by support vector machines (SVMs) to implement the automated detection of heated plumes of the target analyte, ethanol. The interferograms employed in this study were acquired with a downward-looking passive FT-IR spectrometer mounted on a fixed-wing aircraft. Classifiers are trained with data collected on the ground and subsequently used for the airborne detection. The success of the automated detection depends on the effective removal of background contributions from the interferogram segments. Removing the background signature is complicated when the analyte spectral bands are broad because there is significant overlap between the interferogram representations of the analyte and background. Methods to implement the FIR and FIRM filters while excluding background contributions are explored in this work. When properly optimized, both filtering procedures provide satisfactory classification results for the airborne data. Missed detection rates of 8% or smaller for ethanol and false positive rates of at most 0.8% are realized. The optimization of filter design parameters, the starting interferogram point for filtering, and the length of the interferogram segments used in the pattern recognition is discussed.

  4. Passivation on High Q Acoustic Strain Sensor for Accelerometer.

    DTIC Science & Technology

    1984-11-01

    selection of passivation layers. Preliminary results indicated that V203 , (yttrium oxide ) and AIN (aluminum nitride) were the best materials for...thickness selection of passivation layers. Preliminary results indicated that Y203 (yttrium oxide ) and AIN (aluminum nitride) were the best materials...crystal, in this case a parabolic temperature characteristic. Several circuits were designed using varactor diode phase shifting networks. FOjcTl Ta tor

  5. The Utility of Malaria Rapid Diagnostic Tests as a Tool in Enhanced Surveillance for Malaria Elimination in Vanuatu

    PubMed Central

    Guintran, Jean-Olivier; Iata, Harry; Anderson, Karen; Nausien, Johnny; Gresty, Karryn J; Waters, Norman C.; Vestergaard, Lasse S.; Taleo, George; Cheng, Qin

    2016-01-01

    Background As part of efforts to eliminate malaria, Vanuatu has piloted the implementation of enhanced malaria surveillance and response strategies since 2011. This involves passive case detection (PCD) in health facilities, proactive case detection (Pro-ACD) and reactive case detection (Re-ACD) in communities using malaria rapid diagnostic tests (RDTs). While RDTs improve case management, their utility for detection of malaria infections in ACDs in this setting is unclear. Methods The utility of malaria RDTs as diagnostic tools was evaluated in PCD, in five rounds of Pro-ACDs and five rounds of Re-ACDs conducted in Tafea and Torba Provinces between 2011 and 2014. The number of malaria infections detected by RDTs was compared to that detected by PCR from collected used-RDTs. Results PCD in Tafea Province (2013) showed a RDT-positive rate of 0.21% (2/939) and a PCR-positive rate of 0.44% (2/453), indicating less than 1% of suspected malaria cases in Tafea Province were due to malaria. In Pro-ACDs conducted in Tafea and Torba Provinces, RDT-positive rates in 2013 and 2014 were 0.14% (3/2145) and 0% (0/2823), respectively, while the corresponding PCR-positive rates were 0.72% (9/1242) and 0.79% (9/1141). PCR identified villages in both provinces appearing to be transmission foci with a small number of low-density infections, mainly P. falciparum infections. In five rounds of Re-ACD, RDTs did not identify any additional infections while PCR detected only one among 173 subjects screened. Conclusions PCD and Pro-ACDs demonstrate that both Tafea and Torba Provinces in Vanuatu has achieved very low malaria prevalence. In these low-transmission areas, conducting Pro-ACD and Re-ACDs using RDTs appears not cost-effective and may have limited impact on interrupting malaria transmission due to the small number of infections identified by RDTs and considerable operational resources invested. More sensitive, field deployable and affordable diagnostic tools will improve malaria surveillance in malaria elimination settings. PMID:27902755

  6. Real-time detection of mercury ions in water using a reduced graphene oxide/DNA field-effect transistor with assistance of a passivation layer

    DOE PAGES

    Chang, Jingbo; Zhou, Guihua; Gao, Xianfeng; ...

    2015-08-01

    Field-effect transistor (FET) sensors based on reduced graphene oxide (rGO) for detecting chemical species provide a number of distinct advantages, such as ultrasensitivity, label-free, and real-time response. However, without a passivation layer, channel materials directly exposed to an ionic solution could generate multiple signals from ionic conduction through the solution droplet, doping effect, and gating effect. Therefore, a method that provides a passivation layer on the surface of rGO without degrading device performance will significantly improve device sensitivity, in which the conductivity changes solely with the gating effect. In this work, we report rGO FET sensor devices with Hg 2+-dependentmore » DNA as a probe and the use of an Al 2O 3 layer to separate analytes from conducting channel materials. The device shows good electronic stability, excellent lower detection limit (1 nM), and high sensitivity for real-time detection of Hg 2+ in an underwater environment. Our work shows that optimization of an rGO FET structure can provide significant performance enhancement and profound fundamental understanding for the sensor mechanism.« less

  7. A multifrequency evaluation of active and passive microwave sensors for oil spill detection and assessment

    NASA Technical Reports Server (NTRS)

    Fenner, R. G.; Reid, S. C.; Solie, C. H.

    1980-01-01

    An evaluation is given of how active and passive microwave sensors can best be used in oil spill detection and assessment. Radar backscatter curves taken over oil spills are presented and their effect on synthetic aperture radar (SAR) imagery are discussed. Plots of microwave radiometric brightness variations over oil spills are presented and discussed. Recommendations as to how to select the best combination of frequency, viewing angle, and sensor type for evaluation of various aspects of oil spills are also discussed.

  8. Adding tsetse control to medical activities contributes to decreasing transmission of sleeping sickness in the Mandoul focus (Chad)

    PubMed Central

    Mahamat, Mahamat Hissene; Peka, Mallaye; Rayaisse, Jean-Baptiste; Rock, Kat S.; Toko, Mahamat Abdelrahim; Darnas, Justin; Brahim, Guihini Mollo; Yoni, Wilfrid; Tirados, Inaki; Courtin, Fabrice; Brand, Samuel P. C.; Nersy, Cyrus; Alfaroukh, Idriss Oumar; Torr, Steve J.; Lehane, Mike J.; Solano, Philippe

    2017-01-01

    Background Gambian sleeping sickness or HAT (human African trypanosomiasis) is a neglected tropical disease caused by Trypanosoma brucei gambiense transmitted by riverine species of tsetse. A global programme aims to eliminate the disease as a public health problem by 2020 and stop transmission by 2030. In the South of Chad, the Mandoul area is a persistent focus of Gambian sleeping sickness where around 100 HAT cases were still diagnosed and treated annually until 2013. Pre-2014, control of HAT relied solely on case detection and treatment, which lead to a gradual decrease in the number of cases of HAT due to annual screening of the population. Methods Because of the persistence of transmission and detection of new cases, we assessed whether the addition of vector control to case detection and treatment could further reduce transmission and consequently, reduce annual incidence of HAT in Mandoul. In particular, we investigated the impact of deploying ‘tiny targets’ which attract and kill tsetse. Before tsetse control commenced, a census of the human population was conducted and their settlements mapped. A pre-intervention survey of tsetse distribution and abundance was implemented in November 2013 and 2600 targets were deployed in the riverine habitats of tsetse in early 2014, 2015 and 2016. Impact on tsetse and on the incidence of sleeping sickness was assessed through nine tsetse monitoring surveys and four medical surveys of the human population in 2014 and 2015. Mathematical modelling was used to assess the relative impact of tsetse control on incidence compared to active and passive screening. Findings The census indicated that a population of 38674 inhabitants lived in the vicinity of the Mandoul focus. Within this focus in November 2013, the vector is Glossina fuscipes fuscipes and the mean catch of tsetse from traps was 0.7 flies/trap/day (range, 0–26). The catch of tsetse from 44 sentinel biconical traps declined after target deployment with only five tsetse being caught in nine surveys giving a mean catch of 0.005 tsetse/trap/day. Modelling indicates that 70.4% (95% CI: 51–95%) of the reduction in reported cases between 2013 and 2015 can be attributed to vector control with the rest due to medical intervention. Similarly tiny targets are estimated to have reduced new infections dramatically with 62.8% (95% CI: 59–66%) of the reduction due to tsetse control, and 8.5% (95% 8–9%) to enhanced passive detection. Model predictions anticipate that elimination as a public health problem could be achieved by 2018 in this focus if vector control and screening continue at the present level and, furthermore, there may have been virtually no transmission since 2015. Conclusion This work shows that tiny targets reduced the numbers of tsetse in this focus in Chad, which may have interrupted transmission and the combination of tsetse control to medical detection and treatment has played a major role in reducing in HAT incidence in 2014 and 2015. PMID:28750007

  9. The Passive Film Growth Mechanism of New Corrosion-Resistant Steel Rebar in Simulated Concrete Pore Solution: Nanometer Structure and Electrochemical Study

    PubMed Central

    Jiang, Jin-yang; Wang, Danqian; Chu, Hong-yan; Ma, Han; Liu, Yao; Gao, Yun; Shi, Jinjie; Sun, Wei

    2017-01-01

    An elaborative study was carried out on the growth mechanism and properties of the passive film for a new kind of alloyed corrosion-resistant steel (CR steel). The passive film naturally formed in simulated concrete pore solutions (pH = 13.3). The corrosion resistance was evaluated by various methods including open circuit potential (OCP), linear polarization resistance (LPR) measurements, and electrochemical impedance spectroscopy (EIS). Meanwhile, the 2205 duplex stainless steel (SS steel) was evaluated for comparison. Moreover, the passive film with CR steel was studied by means of X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), Atomic Force Microscope (AFM), and the Mott‑Schottky approach. The results showed that the excellent passivity of CR steel could be detected in a high alkaline environment. The grain boundaries between the fine passive film particles lead to increasing Cr oxide content in the later passivation stage. The filling of cation vacancies in the later passivation stage as well as the orderly crystalized inner layer contributed to the excellent corrosion resistance of CR steel. A passive film growth model for CR steel was proposed. PMID:28772772

  10. The Passive Film Growth Mechanism of New Corrosion-Resistant Steel Rebar in Simulated Concrete Pore Solution: Nanometer Structure and Electrochemical Study.

    PubMed

    Jiang, Jin-Yang; Wang, Danqian; Chu, Hong-Yan; Ma, Han; Liu, Yao; Gao, Yun; Shi, Jinjie; Sun, Wei

    2017-04-14

    An elaborative study was carried out on the growth mechanism and properties of the passive film for a new kind of alloyed corrosion-resistant steel (CR steel). The passive film naturally formed in simulated concrete pore solutions (pH = 13.3). The corrosion resistance was evaluated by various methods including open circuit potential (OCP), linear polarization resistance (LPR) measurements, and electrochemical impedance spectroscopy (EIS). Meanwhile, the 2205 duplex stainless steel (SS steel) was evaluated for comparison. Moreover, the passive film with CR steel was studied by means of X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), Atomic Force Microscope (AFM), and the Mott‑Schottky approach. The results showed that the excellent passivity of CR steel could be detected in a high alkaline environment. The grain boundaries between the fine passive film particles lead to increasing Cr oxide content in the later passivation stage. The filling of cation vacancies in the later passivation stage as well as the orderly crystalized inner layer contributed to the excellent corrosion resistance of CR steel. A passive film growth model for CR steel was proposed.

  11. The Burden of Dengue Fever and Chikungunya in Southern Coastal Ecuador: Epidemiology, Clinical Presentation, and Phylogenetics from the First Two Years of a Prospective Study

    PubMed Central

    Stewart-Ibarra, Anna M.; Ryan, Sadie J.; Kenneson, Aileen; King, Christine A.; Abbott, Mark; Barbachano-Guerrero, Arturo; Beltrán-Ayala, Efraín; Borbor-Cordova, Mercy J.; Cárdenas, Washington B.; Cueva, Cinthya; Finkelstein, Julia L.; Lupone, Christina D.; Jarman, Richard G.; Maljkovic Berry, Irina; Mehta, Saurabh; Polhemus, Mark; Silva, Mercy; Endy, Timothy P.

    2018-01-01

    Abstract. Here, we report the findings from the first 2 years (2014–2015) of an arbovirus surveillance study conducted in Machala, Ecuador, a dengue-endemic region. Patients with suspected dengue virus (DENV) infections (index cases, N = 324) were referred from five Ministry of Health clinical sites. A subset of DENV-positive index cases (N = 44) were selected, and individuals from the index household and four neighboring homes within 200 m were recruited (N = 400). Individuals who entered the study, other than the index cases, are referred to as associates. In 2014, 70.9% of index cases and 35.6% of associates had acute or recent DENV infections. In 2015, 28.3% of index cases and 12.8% of associates had acute or recent DENV infections. For every DENV infection captured by passive surveillance, we detected an additional three acute or recent DENV infections in associates. Of associates with acute DENV infections, 68% reported dengue-like symptoms, with the highest prevalence of symptomatic acute infections in children aged less than 10 years. The first chikungunya virus (CHIKV) infections were detected on epidemiological week 12 in 2015; 43.1% of index cases and 3.5% of associates had acute CHIKV infections. No Zika virus infections were detected. Phylogenetic analyses of isolates of DENV from 2014 revealed genetic relatedness and shared ancestry of DENV1, DENV2, and DENV4 genomes from Ecuador with those from Venezuela and Colombia, indicating the presence of viral flow between Ecuador and surrounding countries. Enhanced surveillance studies, such as this, provide high-resolution data on symptomatic and inapparent infections across the population. PMID:29512482

  12. Multi-Sensor Mud Detection

    NASA Technical Reports Server (NTRS)

    Rankin, Arturo L.; Matthies, Larry H.

    2010-01-01

    Robust mud detection is a critical perception requirement for Unmanned Ground Vehicle (UGV) autonomous offroad navigation. A military UGV stuck in a mud body during a mission may have to be sacrificed or rescued, both of which are unattractive options. There are several characteristics of mud that may be detectable with appropriate UGV-mounted sensors. For example, mud only occurs on the ground surface, is cooler than surrounding dry soil during the daytime under nominal weather conditions, is generally darker than surrounding dry soil in visible imagery, and is highly polarized. However, none of these cues are definitive on their own. Dry soil also occurs on the ground surface, shadows, snow, ice, and water can also be cooler than surrounding dry soil, shadows are also darker than surrounding dry soil in visible imagery, and cars, water, and some vegetation are also highly polarized. Shadows, snow, ice, water, cars, and vegetation can all be disambiguated from mud by using a suite of sensors that span multiple bands in the electromagnetic spectrum. Because there are military operations when it is imperative for UGV's to operate without emitting strong, detectable electromagnetic signals, passive sensors are desirable. JPL has developed a daytime mud detection capability using multiple passive imaging sensors. Cues for mud from multiple passive imaging sensors are fused into a single mud detection image using a rule base, and the resultant mud detection is localized in a terrain map using range data generated from a stereo pair of color cameras.

  13. Multistatic GNSS Receiver Array for Passive Air Surveillance

    NASA Astrophysics Data System (ADS)

    Wachtl, Stefan; Koch, Volker; Westphal, Robert; Schmidt, Lorenz-Peter

    2016-03-01

    The performance of a passive air surveillance sensor based on Global Navigation Satellite Systems (GNSS) is mainly limited by the receiver noise efficiency, the achievable signal processing gain and the radar cross section (RCS) of an airplane. For surveillance applications large detection ranges as well as a high probability of detection are crucial parameters. Due to the very low GNSS signal powers received on the earth's surface, high radar cross sections are mandatory to achieve detection ranges for airplanes at some kilometers distance. This paper will discuss a multistatic transmitter and receiver arrangement, which is indispensable to get a reasonable detection rate with respect to a hemispheric field of view. The strong performance dependency of such a sensor on the number of transmitters and receivers will be shown by means of some exemplary simulation results.

  14. Calibrating passive acoustic monitoring: correcting humpback whale call detections for site-specific and time-dependent environmental characteristics.

    PubMed

    Helble, Tyler A; D'Spain, Gerald L; Campbell, Greg S; Hildebrand, John A

    2013-11-01

    This paper demonstrates the importance of accounting for environmental effects on passive underwater acoustic monitoring results. The situation considered is the reduction in shipping off the California coast between 2008-2010 due to the recession and environmental legislation. The resulting variations in ocean noise change the probability of detecting marine mammal vocalizations. An acoustic model was used to calculate the time-varying probability of detecting humpback whale vocalizations under best-guess environmental conditions and varying noise. The uncorrected call counts suggest a diel pattern and an increase in calling over a two-year period; the corrected call counts show minimal evidence of these features.

  15. Presence of active pharmaceutical ingredients in the continuum of surface and ground water used in drinking water production.

    PubMed

    Ahkola, Heidi; Tuominen, Sirkku; Karlsson, Sanja; Perkola, Noora; Huttula, Timo; Saraperä, Sami; Artimo, Aki; Korpiharju, Taina; Äystö, Lauri; Fjäder, Päivi; Assmuth, Timo; Rosendahl, Kirsi; Nysten, Taina

    2017-12-01

    Anthropogenic chemicals in surface water and groundwater cause concern especially when the water is used in drinking water production. Due to their continuous release or spill-over at waste water treatment plants, active pharmaceutical ingredients (APIs) are constantly present in aquatic environment and despite their low concentrations, APIs can still cause effects on the organisms. In the present study, Chemcatcher passive sampling was applied in surface water, surface water intake site, and groundwater observation wells to estimate whether the selected APIs are able to end up in drinking water supply through an artificial groundwater recharge system. The API concentrations measured in conventional wastewater, surface water, and groundwater grab samples were assessed with the results obtained with passive samplers. Out of the 25 APIs studied with passive sampling, four were observed in groundwater and 21 in surface water. This suggests that many anthropogenic APIs released to waste water proceed downstream and can be detectable in groundwater recharge. Chemcatcher passive samplers have previously been used in monitoring several harmful chemicals in surface and wastewaters, but the path of chemicals to groundwater has not been studied. This study provides novel information on the suitability of the Chemcatcher passive samplers for detecting APIs in groundwater wells.

  16. New Developments for Physically-based Falling Snow Retrievals over Land in Preparation for GPM

    NASA Technical Reports Server (NTRS)

    Jackson, Gail S.; Tokay, Ali; Kramer, Anne W.; Hudak, David

    2008-01-01

    The NASA Global Precipitation Measurement mission (GPM) concept centers on deploying a Core spacecraft carrying a dual-frequency precipitation radar and a microwave radiometric imager with channels from 10 to 183 GHz to serve as a precipitation physics observatory and a calibration reference to unify a constellation of dedicated and operational passive microwave sensors. Because of the extended orbit of the Core (plus or minus 65 deg) and the enhanced dual frequency radar and high frequency radiometer, GPM will be able to sense falling snow precipitation and light rain over land. Accordingly, GPM has partnered with the Canadian CloudSat/CALIPSO Validation Project (C3VP) to obtain observations to provide one of several important ground-based validation data sets around which the falling snow models and retrieval algorithms can be further developed and tested. In this work we compare and correlate the long time series (Nov.'06 - March '07) measurements of precipitation rate from parsivels to the passive (89, 150, 183 plus or minus 1, plus or minus 3, plus or minus 7 GHz) observations of NOAA's AMSU-B radiometer. We separate the comparisons into categories of no precipitation, liquid rain and falling snow precipitation. We found that there are similar TBs (especially at 89 and 150 GHz) for cases with falling snow and for non-precipitating cases. The comparisons indicate that surface emissivity contributions to the satellite observed TB over land can add uncertainty in detecting and estimating falling snow. The newest results show that by computing brightness temperatures based on CARE radiosonde data and a rough estimate of surface emissivity show that the cloud ice scattering signal in the AMSU-B data is detected. That is the differences in computed TB and AMSU-B TB for precipitating and non-precipitating cases are unique such that the precipitating and non-precipitating cases can be identified. These results require that the radiosonde releases are within an hour of the AMSU-B data. Forest fraction, snow cover, and measured emissivities were combined to calculate the surface emissivities.

  17. The impact of including passive benefits in cost-effectiveness analysis: the case of automated external defibrillators on commercial aircraft.

    PubMed

    Cram, Peter; Vijan, Sandeep; Wolbrink, Alex; Fendrick, A Mark

    2003-01-01

    Traditional cost-utility analysis assumes that all benefits from health-related interventions are captured by the quality-adjusted life-years (QALYs) gained by the few individuals whose outcome is improved by the intervention. However, it is possible that many individuals who do not directly benefit from an intervention receive utility, and therefore QALYs, because of the passive benefit (aka sense of security) provided by the existence of the intervention. The objective of this study was to evaluate the impact that varying quantities of passive benefit have on the cost-effectiveness of airline defibrillator programs. A decision analytic model with Markov processes was constructed to evaluate the cost-effectiveness of defibrillator deployment on domestic commercial passenger aircraft over 1 year. Airline passengers were assigned small incremental utility gains (.001-.01) during an estimated 3-hour flight to evaluate the impact of passive benefit on overall cost-effectiveness. In the base case analysis with no allowance for passive benefit, the cost-effectiveness of airline automated external defibrillator deployment was US dollars 34000 per QALY gained. If 1% of all passengers received utility gain of.01, the cost-effectiveness declined to US dollars 30000. Cost-effectiveness was enhanced when the quantity of passive benefit was raised or the percentage of individuals receiving passive benefit increased. Automated external defibrillator deployment on passenger aircraft is likely to be cost-effective. If a small percentage of airline passengers receive incremental utility gains from passive benefit of automated external defibrillator availability, the impact on overall cost-effectiveness may be substantial. Further research should attempt to clarify the magnitude and percentage of patients who receive passive benefit.

  18. Photodetectors with passive thermal radiation control

    DOEpatents

    Lin, Shawn-Yu; Fleming, James G.; Dodson, Brian W.

    2001-10-02

    A new class of photodetectors which include means for passive shielding against undesired thermal radiation is disclosed. Such devices can substitute in applications currently requiring cooled optical sensors, such as IR detection and imaging. This description is included for purposes of searching, and is not intended to limit or otherwise influence the interpretation of the present invention.

  19. Quantification of fatigue cracking in CT specimens with passive and active piezoelectric sensing

    NASA Astrophysics Data System (ADS)

    Yu, Jianguo; Ziehl, Paul; Zarate, Boris; Caicedo, Juan; Yu, Lingyu; Giurgiutiu, Victor; Metrovich, Brian; Matta, Fabio

    2010-04-01

    Monitoring of fatigue cracks in steel bridges is of interest to bridge owners and agencies. Monitoring of fatigue cracks has been attempted with acoustic emission using either resonant or broadband sensors. One drawback of passive sensing is that the data is limited to that caused by growing cracks. In this work, passive emission was complemented with active sensing (piezoelectric wafer active sensors) for enhanced detection capabilities. Passive and active sensing methods were described for fatigue crack monitoring on specialized compact tension specimens. The characteristics of acoustic emission were obtained to understand the correlation of acoustic emission behavior and crack growth. Crack and noise induced signals were interpreted through Swansong II Filter and waveform-based approaches, which are appropriate for data interpretation of field tests. Upon detection of crack extension, active sensing was activated to measure the crack size. Model updating techniques were employed to minimize the difference between the numerical results and experimental data. The long term objective of this research is to develop an in-service prognostic system to monitor structural health and to assess the remaining fatigue life.

  20. Grab and passive sampling applied to pesticide analysis in the São Lourenço river headwater in Campo Verde - MT, Brazil.

    PubMed

    Berton, André; Brugnera, Michelle F; Dores, Eliana F G C

    2018-04-03

    In this study, the quality of surface water in the headwaters of São Lourenço River in Mato Grosso, Brazil, was evaluated in relation to contamination by pesticides. For this purpose, samples were collected between December 2015 and June 2016 by grab sampling and by passive sampling using an integrative polar organic compound sampler installed in the field during four 14-day cycles between March and June 2016. The analyses were performed by gas chromatography (CG/MS) and by liquid chromatography (UPLC-MS/MS). The results showed the detection of two pesticides (atrazine and pyraclostrobin) of the five analyzed by passive sampling and eight active principles among the 20 analyzed (malathion, diuron, carbofuran, carbendazim, trifluralin, imidacloprid, metolachlor, and acetamiprid) by grab sampling. The detection of 10 pesticides, even almost a decade after the beginning of a recovery process of the ciliary forest, confirms the headwaters' vulnerability to these contaminants and passive sampling proved to be an important tool in capturing small concentrations of pesticides constituting an interesting complement to grab sampling.

  1. A surface acoustic wave response detection method for passive wireless torque sensor

    NASA Astrophysics Data System (ADS)

    Fan, Yanping; Kong, Ping; Qi, Hongli; Liu, Hongye; Ji, Xiaojun

    2018-01-01

    This paper presents an effective surface acoustic wave (SAW) response detection method for the passive wireless SAW torque sensor to improve the measurement accuracy. An analysis was conducted on the relationship between the response energy-entropy and the bandwidth of SAW resonator (SAWR). A self-correlation method was modified to suppress the blurred white noise and highlight the attenuation characteristic of wireless SAW response. The SAW response was detected according to both the variation and the duration of energy-entropy ascension of an acquired RF signal. Numerical simulation results showed that the SAW response can be detected even when the signal-to-noise ratio (SNR) is 6dB. The proposed SAW response detection method was evaluated with several experiments at different conditions. The SAW response can be well distinguished from the sinusoidal signal and the noise. The performance of the SAW torque measurement system incorporating the detection method was tested. The obtained repeatability error was 0.23% and the linearity was 0.9934, indicating the validity of the detection method.

  2. Socio economic position in TB prevalence and access to services: results from a population prevalence survey and a facility-based survey in Bangladesh.

    PubMed

    Hossain, Shahed; Quaiyum, Mohammad Abdul; Zaman, Khalequ; Banu, Sayera; Husain, Mohammad Ashaque; Islam, Mohammad Akramul; Cooreman, Erwin; Borgdorff, Martien; Lönnroth, Knut; Salim, Abdul Hamid; van Leth, Frank

    2012-01-01

    In Bangladesh DOTS has been provided free of charge since 1993, yet information on access to TB services by different population group is not well documented. The objective of this study was to assess and compare the socio economic position (SEP) of actively detected cases from the community and the cases being routinely detected under National Tuberculosis Control Programme (NTP) in Bangladesh. SEP was assessed by validated asset item for each of the 21,427 households included in the national tuberculosis prevalence survey 2007-2009. A principal component analysis generated household scores and categorized in quartiles. The distribution of 33 actively identified cases was compared with the 240 NTP cases over the identical SEP quartiles to evaluate access to TB services by different groups of the population. The population prevalence of tuberculosis was 5 times higher in the lowest quartiles of population (95.4, 95% CI: 48.0-189.7) to highest quartile population (19.5, 95% CI: 6.9-55.0). Among the 33 cases detected during survey, 25 (75.8%) were from lower two quartiles, and the rest 8 (24.3%) were from upper two quartiles. Among TB cases detected passively under NTP, more than half of them 137 (57.1%) were from uppermost two quartiles, 98 (41%) from the second quartile, and 5 (2%) in the lowest quartile of the population. This distribution is not affected when adjusted for other factors or interactions among them. The findings indicate that despite availability free of charge, DOTS is not equally accessed by the poorer sections of the population. However, these figures should be interpreted with caution since there is a need for additional studies that assess in-depth poverty indicators and its determinants in relation to access of the TB services provided in Bangladesh.

  3. Real time observation and automated measurement of red blood cells agglutination inside a passive microfluidic biochip containing embedded reagents.

    PubMed

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2017-07-15

    The process of agglutination is commonly used for the detection of biomarkers like proteins or viruses. The multiple bindings between micrometer sized particles, either latex beads or red blood cells (RBCs), create aggregates that are easily detectable and give qualitative information about the presence of the biomarkers. In most cases, the detection is made by simple naked-eye observation of agglutinates without any access to the kinetics of agglutination. In this study, we address the development of a real-time time observation of RBCs agglutination. Using ABO blood typing as a proof-of-concept, we developed i) an integrated biological protocol suitable for further use as point-of-care (POC) analysis and ii) two dedicated image processing algorithms for the real-time and quantitative measurement of agglutination. Anti-A or anti-B typing reagents were dried inside the microchannel of a passive microfluidic chip designed to enhance capillary flow. A blood drop deposit at the tip of the biochip established a simple biological protocol. In situ agglutination of autologous RBCs was achieved by means of embedded reagents and real time agglutination process was monitored by video recording. Using a training set of 24 experiments, two real-time indicators based on correlation and variance of gray levels were optimized and then further confirmed on a validation set. 100% correct discrimination between positive and negative agglutinations was performed within less than 2min by measuring real-time evolution of both correlation and variance indicators. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Distributed micro-radar system for detection and tracking of low-profile, low-altitude targets

    NASA Astrophysics Data System (ADS)

    Gorwara, Ashok; Molchanov, Pavlo

    2016-05-01

    Proposed airborne surveillance radar system can detect, locate, track, and classify low-profile, low-altitude targets: from traditional fixed and rotary wing aircraft to non-traditional targets like unmanned aircraft systems (drones) and even small projectiles. Distributed micro-radar system is the next step in the development of passive monopulse direction finder proposed by Stephen E. Lipsky in the 80s. To extend high frequency limit and provide high sensitivity over the broadband of frequencies, multiple angularly spaced directional antennas are coupled with front end circuits and separately connected to a direction finder processor by a digital interface. Integration of antennas with front end circuits allows to exclude waveguide lines which limits system bandwidth and creates frequency dependent phase errors. Digitizing of received signals proximate to antennas allows loose distribution of antennas and dramatically decrease phase errors connected with waveguides. Accuracy of direction finding in proposed micro-radar in this case will be determined by time accuracy of digital processor and sampling frequency. Multi-band, multi-functional antennas can be distributed around the perimeter of a Unmanned Aircraft System (UAS) and connected to the processor by digital interface or can be distributed between swarm/formation of mini/micro UAS and connected wirelessly. Expendable micro-radars can be distributed by perimeter of defense object and create multi-static radar network. Low-profile, lowaltitude, high speed targets, like small projectiles, create a Doppler shift in a narrow frequency band. This signal can be effectively filtrated and detected with high probability. Proposed micro-radar can work in passive, monostatic or bistatic regime.

  5. Use of prospective hospital surveillance data to define spatiotemporal heterogeneity of malaria risk in coastal Kenya.

    PubMed

    Bisanzio, Donal; Mutuku, Francis; LaBeaud, Angelle D; Mungai, Peter L; Muinde, Jackson; Busaidy, Hajara; Mukoko, Dunstan; King, Charles H; Kitron, Uriel

    2015-12-01

    Malaria in coastal Kenya shows spatial heterogeneity and seasonality, which are important factors to account for when planning an effective control system. Routinely collected data at health facilities can be used as a cost-effective method to acquire information on malaria risk for large areas. Here, data collected at one specific hospital in coastal Kenya were used to assess the ability of such passive surveillance to capture spatiotemporal heterogeneity of malaria and effectiveness of an augmented control system. Fever cases were tested for malaria at Msambweni sub-County Referral Hospital, Kwale County, Kenya, from October 2012 to March 2015. Remote sensing data were used to classify the development level of each monitored community and to identify the presence of rice fields nearby. An entomological study was performed to acquire data on the seasonality of malaria vectors in the study area. Rainfall data were obtained from a weather station located in proximity of the study area. Spatial analysis was applied to investigate spatial patterns of malarial and non-malarial fever cases. A space-time Bayesian model was performed to evaluate risk factors and identify locations at high malaria risk. Vector seasonality was analysed using a generalized additive mixed model (GAMM). Among the 25,779 tested febrile cases, 28.7 % were positive for Plasmodium infection. Malarial and non-malarial fever cases showed a marked spatial heterogeneity. High risk of malaria was linked to patient age, community development level and presence of rice fields. The peak of malaria prevalence was recorded close to rainy seasons, which correspond to periods of high vector abundance. Results from the Bayesian model identified areas with significantly high malaria risk. The model also showed that the low prevalence of malaria recorded during late 2012 and early 2013 was associated with a large-scale bed net distribution initiative in the study area during mid-2012. The results indicate that the use of passive surveillance was an effective method to detect spatiotemporal patterns of malaria risk in coastal Kenya. Furthermore, it was possible to estimate the impact of extensive bed net distribution on malaria prevalence among local fever cases over time. Passive surveillance based on georeferenced malaria testing is an important tool that control agencies can use to improve the effectiveness of interventions targeting malaria (and other causes of fever) in such high-risk locations.

  6. Response of CR-39 to 0.9-2.5 MeV protons for KOH and NaOH etching solutions

    NASA Astrophysics Data System (ADS)

    Bahrami, F.; Mianji, F.; Faghihi, R.; Taheri, M.; Ansarinejad, A.

    2016-03-01

    In some circumstances passive detecting methods are the only or preferable measuring approaches. For instance, defining particles' energy profile inside the objects being irradiated with heavy ions and measuring fluence of neutrons or heavy particles in space missions are the cases covered by these methods. In this paper the ability of polyallyl diglycol carbonate (PADC) track detector (commercially known as CR-39) for passive spectrometry of proton particles is studied. Furthermore, the effect of KOH and NaOH as commonly used chemical etching solutions on the response of the detector is investigated. The experiments were carried out with protons in the energy range of 0.94-2.5 MeV generated by a Van de Graaff accelerator. Then, the exposed track dosimeters were etched in the two aforementioned etchants through similar procedure with the same normality of 6.25 N and the same temperature of 85 °C. Formation of the tracks was precisely investigated and the track diameters were recorded following every etching step for each solution using a multistage etching process. The results showed that the proposed method can be efficiently used for the spectrometry of protons over a wider dynamic range and with a reasonable accuracy. Moreover, NaOH and KOH outperformed each other over different regions of the proton energy range. The detection efficiency of both etchants was approximately 100%.

  7. Acoustic occurrence detection of a newly recorded Indo-Pacific humpback dolphin population in waters southwest of Hainan Island, China.

    PubMed

    Dong, Lijun; Liu, Mingming; Dong, Jianchen; Li, Songhai

    2017-11-01

    In 2014, Indo-Pacific humpback dolphins were recorded for the first time in waters southwest of Hainan Island, China. In this paper, the temporal occurrence of Indo-Pacific humpback dolphins in this region was detected by stationary passive acoustic monitoring. During the 130-day observation period (from January to July 2016), 1969 click trains produced by Indo-Pacific humpback dolphins were identified, and 262 ten-minute recording bins contained echolocation click trains of dolphins, of which 70.9% were at night and 29.1% were during the day. A diurnal rhythm with a nighttime peak in acoustic detections was found. Passive acoustic detections indicated that the Indo-Pacific humpback dolphins frequently occurred in this area and were detected mainly at night. This information may be relevant to conservation efforts for these dolphins in the near future.

  8. Performance evaluation of a tailor-made passive sampler for monitoring of tropospheric ozone.

    PubMed

    Ozden, Ozlem; Döğeroğlu, Tuncay

    2012-09-01

    This study presents the performance evaluation of a tailor-made passive sampler developed for the monitoring of tropospheric ozone. The performance of the passive sampler was tested in the field conditions in terms of accuracy, precision, blank values, detection limit, effects of some parameters such as sampling site characteristics and sampling period on the field blanks, self-consistency, experimental and theoretical uptake rates, shelf life and comparison with commercial passive samplers. There was an agreement (R (2) = 0.84) between the responses of passive sampler and the continuous automatic analyser. The accuracy of the sampler, expressed as percent relative error, was obtained lower than 15%. Method precision in terms of coefficient of variance for three simultaneously applied passive samplers was 12%. Sampler detection limit was 2.42 μg m(-3) for an exposure period of 1 week, and the sampler can be stored safely for a period of up to 8 weeks before exposure. Satisfactory self-consistency results showed that extended periods gave the same integrated response as a series of short-term samplers run side by side. The uptake rate of ozone was found to be 10.21 mL min(-1) in a very good agreement with the theoretical uptake rate (10.32 mL min(-1)). The results of the comparison study conducted against a commercially available diffusion tube (Gradko diffusion tube) showed a good linear relationship (R (2) = 0.93) between two passive samplers. The sampler seems suitable to be used in large-scale measurements of ozone where no data are available or the number of existing automated monitors is not sufficient.

  9. Silicone Wristband Passive Samplers Yield Highly Individualized Pesticide Residue Exposure Profiles.

    PubMed

    Aerts, Raf; Joly, Laure; Szternfeld, Philippe; Tsilikas, Khariklia; De Cremer, Koen; Castelain, Philippe; Aerts, Jean-Marie; Van Orshoven, Jos; Somers, Ben; Hendrickx, Marijke; Andjelkovic, Mirjana; Van Nieuwenhuyse, An

    2018-01-02

    Monitoring human exposure to pesticides and pesticide residues (PRs) remains crucial for informing public health policies, despite strict regulation of plant protection product and biocide use. We used 72 low-cost silicone wristbands as noninvasive passive samplers to assess cumulative 5-day exposure of 30 individuals to polar PRs. Ethyl acetate extraction and LC-MS/MS analysis were used for the identification of PRs. Thirty-one PRs were detected of which 15 PRs (48%) were detected only in worn wristbands, not in environmental controls. The PRs included 16 fungicides (52%), 8 insecticides (26%), 2 herbicides (6%), 3 pesticide derivatives (10%), 1 insect repellent (3%), and 1 pesticide synergist (3%). Five detected pesticides were not approved for plant protection use in the EU. Smoking and dietary habits that favor vegetable consumption were associated with higher numbers and higher cumulative concentrations of PRs in wristbands. Wristbands featured unique PR combinations. Our results suggest both environment and diet contributed to PR exposure in our study group. Silicone wristbands could serve as sensitive passive samplers to screen population-wide cumulative dietary and environmental exposure to authorized, unauthorized and banned pesticides.

  10. A Wireless, Fully-Passive Recorder for Medical Applications (2016 Version)

    NASA Astrophysics Data System (ADS)

    Lee, Cedric W.

    This dissertation presents a fully-passive wireless neurorecording system for moni- toring very low level neuropotential. The subject new recording device has no battery, power harvester or regulator. As a result, it addresses concerns related to: (1) exter- nal wired connection (causing lack of mobility and risk of infection in patients), and (2) heat generation that may impact neural functioning. The developed sensor also exhibits large bandwidth and extremely high sensitivity down to 20 muVpp. Specifi- cally, this minimum detectable voltage is 25 times lower than previous fully-passive wireless neurorecorder. Further, for the first time, it allows detection of signals up to 5000 Hz. As a result, it can detect all neural signals of interest. A key aspect of the proposed sensors increased sensitivity is the introduction of an anti-parallel diode pair (APDP) to greatly reduce the second harmonic mixing conversion loss in the implant. Also, a smaller size antenna allows for a less intrusive implant. The implant is excited by an external interrogator possibly integrated within a baseball cap, to power the implanted recorder and reading the neurosignal.

  11. Impact of building forms on thermal performance and thermal comfort conditions in religious buildings in hot climates: a case study in Sharjah city

    NASA Astrophysics Data System (ADS)

    Mushtaha, Emad; Helmy, Omar

    2017-11-01

    The common system used for thermal regulation in mosques of United Arab Emirates (UAE) is the heating, ventilating and air-conditioning (HVAC) system. This system increases demands on energy consumption and increases CO2 emission. A passive design approach is one of the measures to reduce these problems. This study involved an analytical examination of building forms, followed by testing the impact of these forms on its thermal performance and indoor thermal comfort. The tests were conducted using energy simulations software packages. Passive parameters such as shading devices, thermal insulation and natural ventilation were applied in six cases, including the baseline case within each form. The obtained results showed a significant effect of mosque forms as well as passive design techniques on the thermal comfort within the structures. The findings confirmed that the use of passive design alone would not help achieve thermal comfort, but reduce the annual energy consumption by10%. By integrating a hybrid air-conditioning system as another supporting approach, the annual energy consumption could be reduced by 67.5%, which allows for the designing of a much smaller HVAC system.

  12. Comparison of mechanical energy profiles of passive and active below-knee prostheses: a case study.

    PubMed

    Takahashi, Kota Z; Horne, John R; Stanhope, Steven J

    2015-04-01

    With the recent technological advancements of prosthetic lower limbs, there is currently a great desire to objectively evaluate existing prostheses. Using a novel biomechanical analysis, the purpose of this case study was to compare the mechanical energy profiles of anatomical and two disparate prostheses: a passive prosthesis and an active prosthesis. An individual with a transtibial amputation who customarily wears a passive prosthesis (Elation, Össur) and an active prosthesis (BiOM, iWalk, Inc.) and 11 healthy subjects participated in an instrumented gait analysis. The total mechanical power and work of below-knee structures during stance were quantified using a unified deformable segment power analysis. Active prosthesis generated greater peak power and total positive work than passive prosthesis and healthy anatomical limbs. The case study will enhance future efforts to objectively evaluate prosthetic functions during gait in individuals with transtibial amputations. A prosthetic limb should closely replicate the mechanical energy profiles of anatomical limbs. The unified deformable (UD) analysis may be valuable to facilitate future clinical prescription and guide fine adjustments of prosthetic componentry to optimize gait outcomes. © The International Society for Prosthetics and Orthotics 2014.

  13. International Workshop on Detection, Classification and Localization of Marine Mammals Using Passive Acoustics (4th). International Workshop on Density Estimation of Marine Mammals Using Passive Acoustics (1st)

    DTIC Science & Technology

    2009-09-13

    University of Singapore) Olivier Adam (NAMC, Univ. of Paris , France) Len Thomas (Univ St Andrews, Scotland; convenor of the DE workshop...Hervé, Paris Sébastien 90 3 - The Continuous Development for Passive Acoustic Monitoring in Offshore Commercial Industry A. Cucknell and N. Clark...encourage researchers to work on a common dataset, to focus on the same problems, to find original solutions, and to present and compare them at the

  14. Identification of corrosion and damage mechanisms by using scanning electron microscopy and energy-dispersive X-ray microanalysis: contribution to failure analysis case histories

    NASA Astrophysics Data System (ADS)

    Pantazopoulos, G.; Vazdirvanidis, A.

    2014-03-01

    Emphasis is placed on the evaluation of corrosion failures of copper and machineable brass alloys during service. Typical corrosion failures of the presented case histories mainly focussed on stress corrosion cracking and dezincification that acted as the major degradation mechanisms in components used in piping and water supply systems. SEM assessment, coupled with EDS spectroscopy, revealed the main cracking modes together with the root-source(s) that are responsible for the damage initiation and evolution. In addition, fracture surface observations contributed to the identification of the incurred fracture mechanisms and potential environmental issues that stimulated crack initiation and propagation. Very frequently, the detection of chlorides among the corrosion products served as a suggestive evidence of the influence of working environment on passive layer destabilisation and metal dissolution.

  15. Polarization-based index of refraction and reflection angle estimation for remote sensing applications.

    PubMed

    Thilak, Vimal; Voelz, David G; Creusere, Charles D

    2007-10-20

    A passive-polarization-based imaging system records the polarization state of light reflected by objects that are illuminated with an unpolarized and generally uncontrolled source. Such systems can be useful in many remote sensing applications including target detection, object segmentation, and material classification. We present a method to jointly estimate the complex index of refraction and the reflection angle (reflected zenith angle) of a target from multiple measurements collected by a passive polarimeter. An expression for the degree of polarization is derived from the microfacet polarimetric bidirectional reflectance model for the case of scattering in the plane of incidence. Using this expression, we develop a nonlinear least-squares estimation algorithm for extracting an apparent index of refraction and the reflection angle from a set of polarization measurements collected from multiple source positions. Computer simulation results show that the estimation accuracy generally improves with an increasing number of source position measurements. Laboratory results indicate that the proposed method is effective for recovering the reflection angle and that the estimated index of refraction provides a feature vector that is robust to the reflection angle.

  16. A Laboratory-Based Surveillance System for Wuchereria bancrofti in Togo: A Practical Model for Resource-Poor Settings

    PubMed Central

    Mathieu, Els; Dorkenoo, Ameyo; Otogbe, Felix K. J.; Budge, Philip J.; Sodahlon, Yao K.

    2011-01-01

    One goal of the Global Program to Eliminate Lymphatic Filariasis (GAELF) is interruption of disease transmission through annual mass drug administration (MDA) in areas where LF prevalence is greater than 1%. After MDAs are completed, the World Health Organization (WHO) recommends a period of passive surveillance before final certification of LF elimination is achieved. Guidelines for such a surveillance system have yet to be developed. This paper describes a surveillance system launched in Togo in 2006. The system uses existing laboratories with technicians on call at night who, among other activities, prepare nocturnal thick blood smears for malaria diagnosis that can also be used for LF diagnosis. During its first 2 years (2006–2007), the system provided geographically disperse sampling nationwide, and 1 of 750 people residing in Togo was tested. Over the same period, the system detected two cases of LF, both from areas previously considered non-endemic. This system could be a cost-effective, sustainable model for WHO-mandated passive surveillance after cessation of MDA. PMID:21633038

  17. Polarization-based index of refraction and reflection angle estimation for remote sensing applications

    NASA Astrophysics Data System (ADS)

    Thilak, Vimal; Voelz, David G.; Creusere, Charles D.

    2007-10-01

    A passive-polarization-based imaging system records the polarization state of light reflected by objects that are illuminated with an unpolarized and generally uncontrolled source. Such systems can be useful in many remote sensing applications including target detection, object segmentation, and material classification. We present a method to jointly estimate the complex index of refraction and the reflection angle (reflected zenith angle) of a target from multiple measurements collected by a passive polarimeter. An expression for the degree of polarization is derived from the microfacet polarimetric bidirectional reflectance model for the case of scattering in the plane of incidence. Using this expression, we develop a nonlinear least-squares estimation algorithm for extracting an apparent index of refraction and the reflection angle from a set of polarization measurements collected from multiple source positions. Computer simulation results show that the estimation accuracy generally improves with an increasing number of source position measurements. Laboratory results indicate that the proposed method is effective for recovering the reflection angle and that the estimated index of refraction provides a feature vector that is robust to the reflection angle.

  18. Effects of passive and active movement on vibrotactile detection thresholds of the Pacinian channel and forward masking.

    PubMed

    Yıldız, Mustafa Z; Toker, İpek; Özkan, Fatma B; Güçlü, Burak

    2015-01-01

    We investigated the gating effect of passive and active movement on the vibrotactile detection thresholds of the Pacinian (P) psychophysical channel and forward masking. Previous work on gating mostly used electrocutaneous stimulation and did not allow focusing on tactile submodalities. Ten healthy adults participated in our study. Passive movement was achieved by swinging a platform, on which the participant's stimulated hand was attached, manually by a trained operator. The root-mean-square value of the movement speed was kept in a narrow range (slow: 10-20 cm/s, fast: 50-60 cm/s). Active movement was performed by the participant him-/herself using the same apparatus. The tactile stimuli consisted of 250-Hz sinusoidal mechanical vibrations, which were generated by a shaker mounted on the movement platform and applied to the middle fingertip. In the forward-masking experiments, a high-level masking stimulus preceded the test stimulus. Each movement condition was tested separately in a two-interval forced-choice detection task. Both passive and active movement caused a robust gating effect, that is, elevation of thresholds, in the fast speed range. Statistically significant change of thresholds was not found in slow movement conditions. Passive movement yielded higher thresholds than those measured during active movement, but this could not be confirmed statistically. On the other hand, the effect of forward masking was approximately constant as the movement condition varied. These results imply that gating depends on both peripheral and central factors in the P channel. Active movement may have some facilitatory role and produce less gating. Additionally, the results support the hypothesis regarding a critical speed for gating, which may be relevant for daily situations involving vibrations transmitted through grasped objects and for manual exploration.

  19. Preliminary Experiments Using a Passive Detector for Measuring Indoor 220Rn Progeny Concentrations with an Aerosol Chamber.

    PubMed

    Sorimachi, Atsuyuki; Tokonami, Shinji; Kranrod, Chutima; Ishikawa, Tetsuo

    2015-06-01

    This paper describes preliminary experiments using a passive detector for integrating measurements of indoor thoron (²²⁰Rn) progeny concentrations with an aerosol chamber. A solid state nuclear detector (CR-39) covered with a thin aluminum-vaporized polyethylene plate (Mylar film) was used to detect only alpha particles emitted from ²¹²Po due to ²²⁰Rn progeny deposited on the detector surfaces. The initial experiment showed that Mylar film with area density of more than 5 mg cm⁻² was suitable to cut off completely alpha particles of 7.7 MeV from ²¹⁴Po of ²²²Rn progeny decay. In the experiment using the passive detector, it was observed that the net track density increased linearly with an increase of time-integrating ²²⁰Rn progeny concentration. As a result of dividing deposition rates by atom concentrations, the deposition velocity was given as 0.023 cm s⁻¹ for total ²²⁰Rn progeny. The model estimates of deposition velocities were 0.330 cm s⁻¹ for unattached ²²⁰Rn progeny and 0.0011 cm s⁻¹ for aerosol-attached ²²⁰Rn progeny using Lai-Nazaroff formulae. These deposition velocities were in the same range with the results reported in the literature. It was also found that the exposure experiments showed little influence of vertical profiles and surface orientations of the passive detector in the chamber on the detection responses, which was in good agreement with that in the model estimates. Furthermore, it was inferred that the main uncertainty of the passive detector was inhomogeneous deposition of Rn progeny onto its detection surfaces.

  20. Malaria elimination in Botswana, 2012-2014: achievements and challenges.

    PubMed

    Chihanga, Simon; Haque, Ubydul; Chanda, Emmanuel; Mosweunyane, Tjantilili; Moakofhi, Kense; Jibril, Haruna Baba; Motlaleng, Mpho; Zhang, Wenyi; Glass, Gregory E

    2016-02-24

    Botswana significantly reduced its malaria burden between 2000 and 2012. Incidence dropped from 0.99 to 0.01 % and deaths attributed to malaria declined from 12 to 3. The country initiated elimination strategies in October 2012. We examine the progress and challenges during implementation and identify future needs for a successful program in Botswana. A national, rapid notification and response strategy was developed. Cases detected through the routine passive surveillance system at health facilities were intended to initiate screening of contacts around a positive case during follow up. Positive cases were reported to district health management teams to activate district rapid response teams (DRRT). The health facility and the DRRT were to investigate the cases, and screen household members within 100 m of case households within 48 h of notification using rapid diagnostic tests (RDT) and microscopy. Positive malaria cases detected in health facilities were used for spatial analysis. There were 1808 malaria cases recorded in Botswana during 26 months from October, 2012 to December, 2014. Males were more frequently infected (59%) than females. Most cases (60%) were reported from Okavango district which experienced an outbreak in 2013 and 2014. Among the factors creating challenges for malaria eradication, only 1148 cases (63.5%) were captured by the required standardized notification forms. In total, 1080 notified cases were diagnosed by RDT. Of the positive malaria cases, only 227 (12.6%) were monitored at the household level. One hundred (8.7%) cases were associated with national or transnational movement of patients. Local movements of infected individuals within Botswana accounted for 31 cases while 69 (6.01%) cases were imported from other countries. Screening individuals in and around index households identified 37 additional, asymptomatic infections. Oscillating, sporadic and new malaria hot-spots were detected in Botswana during the study period. Botswana's experience shows some of the practical challenges of elimination efforts. Among them are the substantial movements of human infections within and among countries, and the persistence of asymptomatic reservoir infections. Programmatically, challenges include improving the speed of communicating and improving the thoroughness when responding to newly identified cases. The country needs further sustainable interventions to target infections if it is to successfully achieve its elimination goal.

  1. Radio-Frequency Interference (RFI) Mitigation for the Soil, Moisture Active/Passive (SMAP) Radiometer

    NASA Technical Reports Server (NTRS)

    Bradley, Damon; Brambora, Cliff; Wong, Mark Englin; Miles, Lynn; Durachka, David; Farmer, Brian; Mohammed, Priscilla; Piepmier, Jeff; Medeiros, Jim; Martin Neil; hide

    2010-01-01

    The presence of anthropogenic RFI is expected to adversely impact soil moisture measurement by NASA s Soil Moisture Active Passive mission. The digital signal processing approach and preliminary design for detecting and mitigating this RFI is presented in this paper. This approach is largely based upon the work of Johnson and Ruf.

  2. [Passive inhalation of cannabis smoke--is it detectable?].

    PubMed

    Westin, Andreas Austgulen; Slørdal, Lars

    2009-01-15

    It is frequently questioned whether cannabinoids are detectable in urine from individuals having been passively exposed to hashish or marihuana smoke. Literature was reviewed to shed light on an issue that is often debated in the health services, judicial system and in sports. A Medline search with the index terms "cannabis", "hashish", "marihuana" was conducted in September 2007. Summaries, abstracts and reference lists of selected articles were screened for relevancy. Seven experimental studies with humans were identified. Cannabinoids were detected in urine in two studies where the subjects had been exposed to high smoke levels. In studies conducted under less extreme conditions no urine samples were positive for more than a few hours after exposure and the measured cannabinoid levels were low. When cannabinoids are detected in urine with conventional methods and limits of quantification the results are commensurate with active smoking.

  3. Combined passive detection and ultrafast active imaging of cavitation events induced by short pulses of high-intensity ultrasound.

    PubMed

    Gateau, Jérôme; Aubry, Jean-François; Pernot, Mathieu; Fink, Mathias; Tanter, Mickaël

    2011-03-01

    The activation of natural gas nuclei to induce larger bubbles is possible using short ultrasonic excitations of high amplitude, and is required for ultrasound cavitation therapies. However, little is known about the distribution of nuclei in tissues. Therefore, the acoustic pressure level necessary to generate bubbles in a targeted zone and their exact location are currently difficult to predict. To monitor the initiation of cavitation activity, a novel all-ultrasound technique sensitive to single nucleation events is presented here. It is based on combined passive detection and ultrafast active imaging over a large volume using the same multi-element probe. Bubble nucleation was induced using a focused transducer (660 kHz, f-number = 1) driven by a high-power electric burst (up to 300 W) of one to two cycles. Detection was performed with a linear array (4 to 7 MHz) aligned with the single-element focal point. In vitro experiments in gelatin gel and muscular tissue are presented. The synchronized passive detection enabled radio-frequency data to be recorded, comprising high-frequency coherent wave fronts as signatures of the acoustic emissions linked to the activation of the nuclei. Active change detection images were obtained by subtracting echoes collected in the unnucleated medium. These indicated the appearance of stable cavitating regions. Because of the ultrafast frame rate, active detection occurred as quickly as 330 μs after the high-amplitude excitation and the dynamics of the induced regions were studied individually.

  4. Combined passive detection and ultrafast active imaging of cavitation events induced by short pulses of high-intensity ultrasound

    PubMed Central

    Gateau, Jérôme; Aubry, Jean-François; Pernot, Mathieu; Fink, Mathias; Tanter, Mickaël

    2011-01-01

    The activation of natural gas nuclei to induce larger bubbles is possible using short ultrasonic excitations of high amplitude, and is required for ultrasound cavitation therapies. However, little is known about the distribution of nuclei in tissues. Therefore, the acoustic pressure level necessary to generate bubbles in a targeted zone and their exact location are currently difficult to predict. In order to monitor the initiation of cavitation activity, a novel all-ultrasound technique sensitive to single nucleation events is presented here. It is based on combined passive detection and ultrafast active imaging over a large volume and with the same multi-element probe. Bubble nucleation was induced with a focused transducer (660kHz, f#=1) driven by a high power (up to 300 W) electric burst of one to two cycles. Detection was performed with a linear array (4–7MHz) aligned with the single-element focal point. In vitro experiments in gelatin gel and muscular tissue are presented. The synchronized passive detection enabled radio-frequency data to be recorded, comprising high-frequency coherent wave fronts as signatures of the acoustic emissions linked to the activation of the nuclei. Active change detection images were obtained by subtracting echoes collected in the unucleated medium. These indicated the appearance of stable cavitating regions. Thanks to the ultrafast frame rate, active detection occurred as soon as 330 μs after the high amplitude excitation and the dynamics of the induced regions were studied individually. PMID:21429844

  5. Comparison of a novel passive sampler to standard water-column sampling for organic contaminants associated with wastewater effluents entering a New Jersey stream

    USGS Publications Warehouse

    Alvarez, D.A.; Stackelberg, P.E.; Petty, J.D.; Huckins, J.N.; Furlong, E.T.; Zaugg, S.D.; Meyer, M.T.

    2005-01-01

    Four water samples collected using standard depth and width water-column sampling methodology were compared to an innovative passive, in situ, sampler (the polar organic chemical integrative sampler or POCIS) for the detection of 96 organic wastewater-related contaminants (OWCs) in a stream that receives agricultural, municipal, and industrial wastewaters. Thirty-two OWCs were identified in POCIS extracts whereas 9-24 were identified in individual water-column samples demonstrating the utility of POCIS for identifying contaminants whose occurrence are transient or whose concentrations are below routine analytical detection limits. Overall, 10 OWCs were identified exclusively in the POCIS extracts and only six solely identified in the water-column samples, however, repetitive water samples taken using the standard method during the POCIS deployment period required multiple trips to the sampling site and an increased number of samples to store, process, and analyze. Due to the greater number of OWCs detected in the POCIS extracts as compared to individual water-column samples, the ease of performing a single deployment as compared to collecting and processing multiple water samples, the greater mass of chemical residues sequestered, and the ability to detect chemicals which dissipate quickly, the passive sampling technique offers an efficient and effective alternative for detecting OWCs in our waterways for wastewater contaminants.

  6. Medical Image Tamper Detection Based on Passive Image Authentication.

    PubMed

    Ulutas, Guzin; Ustubioglu, Arda; Ustubioglu, Beste; V Nabiyev, Vasif; Ulutas, Mustafa

    2017-12-01

    Telemedicine has gained popularity in recent years. Medical images can be transferred over the Internet to enable the telediagnosis between medical staffs and to make the patient's history accessible to medical staff from anywhere. Therefore, integrity protection of the medical image is a serious concern due to the broadcast nature of the Internet. Some watermarking techniques are proposed to control the integrity of medical images. However, they require embedding of extra information (watermark) into image before transmission. It decreases visual quality of the medical image and can cause false diagnosis. The proposed method uses passive image authentication mechanism to detect the tampered regions on medical images. Structural texture information is obtained from the medical image by using local binary pattern rotation invariant (LBPROT) to make the keypoint extraction techniques more successful. Keypoints on the texture image are obtained with scale invariant feature transform (SIFT). Tampered regions are detected by the method by matching the keypoints. The method improves the keypoint-based passive image authentication mechanism (they do not detect tampering when the smooth region is used for covering an object) by using LBPROT before keypoint extraction because smooth regions also have texture information. Experimental results show that the method detects tampered regions on the medical images even if the forged image has undergone some attacks (Gaussian blurring/additive white Gaussian noise) or the forged regions are scaled/rotated before pasting.

  7. Stylistic features of case reports as a genre of medical discourse.

    PubMed

    Lysanets, Yuliia; Morokhovets, Halyna; Bieliaieva, Olena

    2017-03-13

    The present paper discusses the lexical and grammatical peculiarities of English language medical case reports, taking into account their communicative purposes and intentions. The objective of the research is to clarify the principal mechanisms of producing an effective English language medical case report and thus to provide recommendations and guidelines for medical professionals who will deal with this genre. The analysis of medical case reports will largely focus on the most significant linguistic peculiarities, such as the use of active and passive voice, the choice of particular verb tenses, and pronouns. The selected medical case reports will be considered using methods of lexico-grammatical analysis, quantitative examination, and contextual, structural, narrative, and stylistic analyses. The research revealed a range of important stylistic features of medical case reports which markedly distinguish them from other genres of medical scientific writing: educational and instructive intentions, conciseness and brevity, direct and personal tone, and material presented in a narrative style. The present research has shown that the communicative strategies of the analyzed discourse, mentioned immediately above, are effectively implemented by means of specific lexical units and grammatical structures: the dominance of active voice sentences, past simple tense, personal pronouns, and modal verbs. The research has also detected the occasional use of the present perfect, present simple, and future simple tenses and passive voice which also serve particular communicative purposes of medical case reports. Medical case reports possess a range of unique characteristics which differ from those of research articles and other scientific genres within the framework of written medical discourse. It is to be emphasized that it is highly important for medical professionals to master the major stylistic principles and communicative intentions of medical case report as a genre in order to share their findings with fellow researchers from all over the world. Hence, in the process of training future medical researchers, the analysis of the basic mechanisms of writing a medical case report should be an integral part of the curricula in English for Specific Purposes at universities.

  8. Combining Passive Thermography and Acoustic Emission for Large Area Fatigue Damage Growth Assessment of a Composite Structure

    NASA Technical Reports Server (NTRS)

    Zalameda, Joseph N.; Horne, Michael R.; Madaras, Eric I.; Burke, Eric R.

    2016-01-01

    Passive thermography and acoustic emission data were obtained for improved real time damage detection during fatigue loading. A strong positive correlation was demonstrated between acoustic energy event location and thermal heating, especially if the structure under load was nearing ultimate failure. An image processing routine was developed to map the acoustic emission data onto the thermal imagery. This required removing optical barrel distortion and angular rotation from the thermal data. The acoustic emission data were then mapped onto thermal data, revealing the cluster of acoustic emission event locations around the thermal signatures of interest. By combining both techniques, progression of damage growth is confirmed and areas of failure are identified. This technology provides improved real time inspections of advanced composite structures during fatigue testing.Keywords: Thermal nondestructive evaluation, fatigue damage detection, aerospace composite inspection, acoustic emission, passive thermography

  9. Automatic vehicle location system

    NASA Technical Reports Server (NTRS)

    Hansen, G. R., Jr. (Inventor)

    1973-01-01

    An automatic vehicle detection system is disclosed, in which each vehicle whose location is to be detected carries active means which interact with passive elements at each location to be identified. The passive elements comprise a plurality of passive loops arranged in a sequence along the travel direction. Each of the loops is tuned to a chosen frequency so that the sequence of the frequencies defines the location code. As the vehicle traverses the sequence of the loops as it passes over each loop, signals only at the frequency of the loop being passed over are coupled from a vehicle transmitter to a vehicle receiver. The frequencies of the received signals in the receiver produce outputs which together represent a code of the traversed location. The code location is defined by a painted pattern which reflects light to a vehicle carried detector whose output is used to derive the code defined by the pattern.

  10. Preliminary results of the Source China Sea passive source OBS array experiment

    NASA Astrophysics Data System (ADS)

    Yang, T.; Liu, C.; Pei, Y.; Xia, S.

    2013-12-01

    The Scarborough, or Huangyan, Seamount chain in South China Sea (SCS) represents an extreme case of the global mid-ocean ridge system where the magmatism continues for many million years after the cessation of spreading. To understand this unique process, the South China Sea Deep (SCSD) program funded an experiment deploying a passive source OBS array to image the lithospheric structure beneath the extinct ridge. In April 2012, 18 passive source OBSs, including 15 Guralp CMG-40T OBS and 3 I-4C OBS, were deployed around the Huangyan Island for one year. 11 OBSs were successfully recovered this April, and their data are being processed. Here we present some preliminary results from analyses of this dataset, including the general quality of three-component seismograms, characteristics of seafloor ambient noise spectra, determining the OBS orientation from the Rayleigh wave polarization, and the dispersion analysis of Rayleigh waves. We found that, for most stations, seismograms from teleseismic, regional and local events are generally good with the horizontal records being comparable with vertical component. The noise levels in these seafloor stations are much higher than land-based stations, especially in shorter periods, likely suggesting the direct and stronger impact from the tempestuous SCS. Applications of more sophisticated seismic techniques such as surface wave tomography, seismic anisotropy, receiver function and ambient noise cross-correlation are underway. In addition to the low recovery rate, there are other lessons learned from this experiment. For example, at least two stations have detectable timing problems; Airgun shots should have been used to constrain the timings and orientations in both deployment and recovery. It is still challenging and costly to carry out long-term passive source seismic observations in deep sea.

  11. Microwave responses of the western North Atlantic

    NASA Technical Reports Server (NTRS)

    Stacey, J. M.; Girard, M. A.

    1985-01-01

    Features and objects in the Western North Atlantic Ocean - the Eastern Seaboard of the United States - are observed from Earth orbit by passive microwaves. The intensities of their radiated flux signatures are measured and displayed in color as a microwave flux image. The features of flux emitting objects such as the course of the Gulf Stream and the occurrence of cold eddies near the Gulf Stream are identified by contoured patterns of relative flux intensities. The flux signatures of ships and their wakes are displayed and discussed. Metal data buoys and aircraft are detected. Signal to clutter ratios and probabilities of detection are computed from their measured irradiances. Theoretical models and the range equations that explain passive microwave detection using the irradiances of natural sources are summarized.

  12. Shaking table experimentation on adjacent structures controlled by passive and semi-active MR dampers

    NASA Astrophysics Data System (ADS)

    Basili, M.; De Angelis, M.; Fraraccio, G.

    2013-06-01

    This paper presents the results of shaking table tests on adjacent structures controlled by passive and semi-active MR dampers. The aim was to demonstrate experimentally the effectiveness of passive and semi-active strategies in reducing structural vibrations due to seismic excitation. The physical model at issue was represented by two adjacent steel structures, respectively of 4 and 2 levels, connected at the second level by a MR damper. When the device operated in semi-active mode, an ON-OFF control algorithm, derived by the Lyapunov stability theory, was implemented and experimentally validated. Since the experimentation concerned adjacent structures, two control objectives have been reached: global and selective protection. In case of global protection, the attention was focused on protecting both structures, whereas, in case of selective protection, the attention was focused on protecting only one structure. For each objective the effectiveness of passive control has been compared with the situation of no control and then the effectiveness of semi-active control has been compared with the passive one. The quantities directly compared have been: measured displacements, accelerations and force-displacement of the MR damper, moreover some global response quantities have been estimated from experimental measures, which are the base share force and the base bending moment, the input energy and the energy dissipated by the device. In order to evaluate the effectiveness of the control action in both passive and semi-active case, an energy index EDI, previously defined and already often applied numerically, has been utilized. The aspects investigated in the experimentation have been: the implementation and validation of the control algorithm for selective and global protection, the MR damper input voltage influence, the kind of seismic input and its intensity.

  13. Radio Frequency Interference Detection for Passive Remote Sensing Using Eigenvalue Analysis

    NASA Technical Reports Server (NTRS)

    Schoenwald, Adam; Kim, Seung-Jun; Mohammed-Tano, Priscilla

    2017-01-01

    Radio frequency interference (RFI) can corrupt passive remote sensing measurements taken with microwave radiometers. With the increasingly utilized spectrum and the push for larger bandwidth radiometers, the likelihood of RFI contamination has grown significantly. In this work, an eigenvalue-based algorithm is developed to detect the presence of RFI and provide estimates of RFI-free radiation levels. Simulated tests show that the proposed detector outperforms conventional kurtosis-based RFI detectors in the low-to-medium interferece-to-noise-power-ratio (INR) regime under continuous wave (CW) and quadrature phase shift keying (QPSK) RFIs.

  14. Radio Frequency Interference Detection for Passive Remote Sensing Using Eigenvalue Analysis

    NASA Technical Reports Server (NTRS)

    Schoenwald, Adam J.; Kim, Seung-Jun; Mohammed, Priscilla N.

    2017-01-01

    Radio frequency interference (RFI) can corrupt passive remote sensing measurements taken with microwave radiometers. With the increasingly utilized spectrum and the push for larger bandwidth radiometers, the likelihood of RFI contamination has grown significantly. In this work, an eigenvalue-based algorithm is developed to detect the presence of RFI and provide estimates of RFI-free radiation levels. Simulated tests show that the proposed detector outperforms conventional kurtosis-based RFI detectors in the low-to-medium interference-to-noise-power-ratio (INR) regime under continuous wave (CW) and quadrature phase shift keying (QPSK) RFIs.

  15. Distress detection, location, and communications using advanced space technology

    NASA Technical Reports Server (NTRS)

    Sivertson, W. E., Jr.

    1977-01-01

    This paper briefly introduces a concept for low-cost, global, day-night, all-weather disaster warning and assistance. Evolving, advanced space technology with passive radio frequency reflectors in conjunction with an imaging synthetic aperture radar is employed to detect, identify, locate, and provide passive communication with earth users in distress. This concept evolved from a broad NASA research on new global search and rescue techniques. Appropriate airborne radar test results from this research are reviewed and related to potential disaster applications. The analysis indicates the approach has promise for disaster communications relative to floods, droughts, earthquakes, volcanic eruptions, and severe storms.

  16. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Excellent Passivation of p-Type Si Surface by Sol-Gel Al2O3 Films

    NASA Astrophysics Data System (ADS)

    Xiao, Hai-Qing; Zhou, Chun-Lan; Cao, Xiao-Ning; Wang, Wen-Jing; Zhao, Lei; Li, Hai-Ling; Diao, Hong-Wei

    2009-08-01

    Al2O3 films with a thickness of about 100 nm synthesized by spin coating and thermally treated are applied for field-induced surface passivation of p-type crystalline silicon. The level of surface passivation is determined by techniques based on photoconductance. An effective surface recombination velocity below 100 cm/s is obtained on 10Ω ·cm p-type c-Si wafers (Cz Si). A high density of negative fixed charges in the order of 1012 cm-2 is detected in the Al2O3 films and its impact on the level of surface passivation is demonstrated experimentally. Furthermore, a comparison between the surface passivation achieved for thermal SiO2 and plasma enhanced chemical vapor deposition SiNx:H films on the same c-Si is presented. The high negative fixed charge density explains the excellent passivation of p-type c-Si by Al2O3.

  17. Association between lifetime exposure to passive smoking and risk of breast cancer subtypes defined by hormone receptor status among non-smoking Caucasian women

    PubMed Central

    Strumylaite, Loreta; Kregzdyte, Rima; Poskiene, Lina; Bogusevicius, Algirdas; Pranys, Darius; Norkute, Roberta

    2017-01-01

    Tobacco smoking is inconsistently associated with breast cancer. Although some studies suggest that breast cancer risk is related to passive smoking, little is known about the association with breast cancer by tumor hormone receptor status. We aimed to explore the association between lifetime passive smoking and risk of breast cancer subtypes defined by estrogen receptor and progesterone receptor status among non-smoking Caucasian women. A hospital-based case-control study was performed in 585 cases and 1170 controls aged 28–90 years. Information on lifetime passive smoking and other factors was collected via a self-administered questionnaire. Logistic regression was used for analyses restricted to the 449 cases and 930 controls who had never smoked actively. All statistical tests were two-sided. Adjusted odds ratio of breast cancer was 1.01 (95% confidence interval (CI): 0.72–1.41) in women who experienced exposure to passive smoking at work, 1.88 (95% CI: 1.38–2.55) in women who had exposure at home, and 2.80 (95% CI: 1.84–4.25) in women who were exposed at home and at work, all compared with never exposed regularly. Increased risk was associated with longer exposure: women exposed ≤ 20 years and > 20 years had 1.27 (95% CI: 0.97–1.66) and 2.64 (95% CI: 1.87–3.74) times higher risk of breast cancer compared with never exposed (Ptrend < 0.001). The association of passive smoking with hormone receptor-positive breast cancer did not differ from that with hormone receptor-negative breast cancer (Pheterogeneity > 0.05). There was evidence of interaction between passive smoking intensity and menopausal status in both overall group (P = 0.02) and hormone receptor-positive breast cancer group (P < 0.05). In Caucasian women, lifetime exposure to passive smoking is associated with the risk of breast cancer independent of tumor hormone receptor status with the strongest association in postmenopausal women. PMID:28151962

  18. Underreporting of congenital rubella in Italy, 2010-2014.

    PubMed

    Giambi, Cristina; Bella, Antonino; Filia, Antonietta; Del Manso, Martina; Nacca, Gloria; Declich, Silvia; Rota, Maria Cristina

    2017-07-01

    In accordance with the goals of the World Health Organization Regional Committee for Europe, the Italian national Measles and Rubella Elimination Plan 2010-2015 aimed to reduce the incidence of congenital rubella cases to <1 case/100,000 live births by 2015. In Italy, a passive national surveillance system for congenital rubella and rubella in pregnancy is active since 2005. We estimated the degree of underreporting of congenital rubella, performing a capture-recapture analysis of cases detected through two independent sources: the national surveillance system and the national hospital discharge database, in the years 2010-2014. We found that 6 out of 11 cases tracked in the retrospective case-finding from hospital registries had not been notified to the surveillance system, and we estimated a degree of underreporting of 53% for the period 2010-2014. This approach showed to be simple to perform, repeatable, and effective. In order to reduce underreporting, some actions aimed at strengthening surveillance procedures are needed. The adoption on a routine basis of the review of hospital discharge registries for case-finding, monthly zero-reporting, and actions to train and sensitize all the specialists involved in the care of pregnant women and the newborns to notification procedures are recommended. What is Known • In Italy, the incidence of congenital rubella was below the WHO target of 1/100,000 live births in 2005-2015, except for two peaks in 2008 and 2012 (5 and 4/100,000, respectively). • Further efforts are required to improve congenital rubella surveillance so that it is more sensitive and specific. The WHO proposes retrospective case-finding from hospital records as an alternative approach to detect infants with congenital rubella. What is New • Underreporting of congenital rubella in Italy was 53% in 2010-2014. • Hospital discharge registries resulted to be an appropriate source to detect congenital rubella cases.

  19. The contribution of a non-governmental organisation's Community Based Tuberculosis Care Programme to case finding in Myanmar: trend over time.

    PubMed

    Maung, Htet Myet Win; Saw, Saw; Isaakidis, Petros; Khogali, Mohammed; Reid, Anthony; Hoa, Nguyen Binh; Zaw, Ko Ko; Thein, Saw; Aung, Si Thu

    2017-04-03

    It is estimated that the standard, passive case finding (PCF) strategy for detecting cases of tuberculosis (TB) in Myanmar has not been successful: 26% of cases are missing. Therefore, alternative strategies, such as active case finding (ACF) by community volunteers, have been initiated since 2011. This study aimed to assess the contribution of a Community Based TB Care Programme (CBTC) by local non-government organizations (NGOs) to TB case finding in Myanmar over 4 years. This was a descriptive study using routine, monitoring data. Original data from the NGOs were sent to a central registry within the National TB Programme and data for this study were extracted from that database. Data from all 84 project townships in five regions and three states in Myanmar were used. The project was launched in 2011. Over time, the number of presumptive TB cases that were referred decreased, except in the Yangon Region, although in some areas, the numbers fluctuated. At the same time, there was a trend for the proportion of cases treated, compared to those referred, that decreased over time (P = 0.051). Overall, among 84 townships, the contribution of CBTC to total case detection deceased from 6% to 4% over time (P < 0.001). Contrary to expectations and evidence from previous studies in other countries, a concerning reduction in TB case finding by local NGO volunteer networks in several areas in Myanmar was recorded over 4 years. This suggests that measures to support the volunteer network and improve its performance are needed. They may include discussion with local NGOs human resources personnel, incentives for the volunteers, closer supervision of volunteers and improved monitoring and evaluation tools.

  20. Altered Passive Eruption Complicating Optimal Orthodontic Bracket Placement: A Case Report and Review of Literature.

    PubMed

    Pulgaonkar, Rohan; Chitra, Prasad

    2015-11-01

    An unusual case of altered passive eruption with gingival hyperpigmentation and a Class I malocclusion in a 12-year-old girl having no previous history of medication is presented. The patient reported with spacing in the upper arch, moderate crowding in the lower arch, anterior crossbite and excessive gingival tissue on the labial surfaces of teeth in both the arches. The inadequate crown lengths made placement of the orthodontic brackets difficult. Preadjusted orthodontic brackets have a very precise placement protocol which can affect tooth movement in all 3 planes of space if violated. The periodontal condition was diagnosed as altered passive eruption Type IA. Interdisciplinary treatment protocols including periodontal surgical and orthodontic procedures were used. The periodontal surgical procedures were carried out prior to orthodontic therapy and the results obtained were satisfactory. It is suggested that orthodontists should be aware of conditions like altered passive eruption and modalities of management. In most instances, orthodontic therapy is not hindered.

  1. Passive smoking and cooking oil fumes (COF) may modify the association between tea consumption and oral cancer in Chinese women.

    PubMed

    Chen, Fa; He, Baochang; Hu, Zhijian; Huang, Jiangfeng; Liu, Fangping; Yan, Lingjun; Lin, Zheng; Zheng, Xiaoyan; Lin, Lisong; Zhang, Zuofeng; Cai, Lin

    2016-05-01

    To evaluate the confounding effects of passive smoking and COF exposure on association between tea and oral cancer in Chinese women. A case-control study including 207 female oral cancer cases and 480 age-matched controls was performed in Fujian, China. Data were collected with a structured questionnaire by face-to-face interviews. The effects of tea consumption on oral cancer were, respectively, adjusted for Model-1 and Model-2 using logistic regression analysis. Model-1 did not adjusted for passive smoking and COF; Model-2 included the variables in Model-1, passive smoking and COF. Tea consumption was associated with a decreased risk of oral cancer in females: The OR was 0.498 (95 % CI 0.312-0.795) for Model-1 and 0.565 (95 % CI 0.352-0.907) for Model-2. The ORs for all the categories of tea consumption estimated by Model-2 were slightly higher than Model-1. When stratified by passive smoking, the statistically significant association between tea drinking and oral cancer was only emerged in non-passive smoking women. Stratification by COF found tea drinking was still associated with a decreased risk of oral cancer for women who have light-COF exposure, but an increased risk for those who subjected to heavy exposure. A negative, multiplicative interaction was found between tea consumption and COF exposure for oral cancer, but not found between tea consumption and passive smoking. Tea consumption reduces the risk of oral cancer in Chinese women, but this effect is modified by the carcinogenic effects of passive smoking and COF exposure.

  2. Extraction of thermal Green's function using diffuse fields: a passive approach applied to thermography

    NASA Astrophysics Data System (ADS)

    Capriotti, Margherita; Sternini, Simone; Lanza di Scalea, Francesco; Mariani, Stefano

    2016-04-01

    In the field of non-destructive evaluation, defect detection and visualization can be performed exploiting different techniques relying either on an active or a passive approach. In the following paper the passive technique is investigated due to its numerous advantages and its application to thermography is explored. In previous works, it has been shown that it is possible to reconstruct the Green's function between any pair of points of a sensing grid by using noise originated from diffuse fields in acoustic environments. The extraction of the Green's function can be achieved by cross-correlating these random recorded waves. Averaging, filtering and length of the measured signals play an important role in this process. This concept is here applied in an NDE perspective utilizing thermal fluctuations present on structural materials. Temperature variations interacting with thermal properties of the specimen allow for the characterization of the material and its health condition. The exploitation of the thermographic image resolution as a dense grid of sensors constitutes the basic idea underlying passive thermography. Particular attention will be placed on the creation of a proper diffuse thermal field, studying the number, placement and excitation signal of heat sources. Results from numerical simulations will be presented to assess the capabilities and performances of the passive thermal technique devoted to defect detection and imaging of structural components.

  3. The effect of tibio-femoral traction mobilization on passive knee flexion motion impairment and pain: a case series

    PubMed Central

    Maher, Sara; Creighton, Doug; Kondratek, Melodie; Krauss, John; Qu, Xianggui

    2010-01-01

    The purpose of this case series was to explore the effects of tibio-femoral (TF) manual traction on pain and passive range of motion (PROM) in individuals with unilateral motion impairment and pain in knee flexion. Thirteen participants volunteered for the study. All participants received 6 minutes of TF traction mobilization applied at end-range passive knee flexion. PROM measurements were taken before the intervention and after 2, 4, and 6 minutes of TF joint traction. Pain was measured using a visual analog scale with the TF joint at rest, at end-range passive knee flexion, during the application of joint traction, and immediately post-treatment. There were significant differences in PROM after 2 and 4 minutes of traction, with no significance noted after 4 minutes. A significant change in knee flexion of 25.9°, which exceeded the MDC95, was found when comparing PROM measurements pre- to final intervention. While pain did not change significantly over time, pain levels did change significantly during each treatment session. Pain significantly increased when the participant’s knee was passively flexed to end range; it was reduced, although not significantly, during traction mobilization; and it significantly decreased following traction. This case series supports TF joint traction as a means of stretching shortened articular and periarticular tissues without increasing reported levels of pain during or after treatment. In addition, this is the first study documenting the temporal aspects of treatment effectiveness in motion restoration. PMID:21655421

  4. Estimating animal population density using passive acoustics.

    PubMed

    Marques, Tiago A; Thomas, Len; Martin, Stephen W; Mellinger, David K; Ward, Jessica A; Moretti, David J; Harris, Danielle; Tyack, Peter L

    2013-05-01

    Reliable estimation of the size or density of wild animal populations is very important for effective wildlife management, conservation and ecology. Currently, the most widely used methods for obtaining such estimates involve either sighting animals from transect lines or some form of capture-recapture on marked or uniquely identifiable individuals. However, many species are difficult to sight, and cannot be easily marked or recaptured. Some of these species produce readily identifiable sounds, providing an opportunity to use passive acoustic data to estimate animal density. In addition, even for species for which other visually based methods are feasible, passive acoustic methods offer the potential for greater detection ranges in some environments (e.g. underwater or in dense forest), and hence potentially better precision. Automated data collection means that surveys can take place at times and in places where it would be too expensive or dangerous to send human observers. Here, we present an overview of animal density estimation using passive acoustic data, a relatively new and fast-developing field. We review the types of data and methodological approaches currently available to researchers and we provide a framework for acoustics-based density estimation, illustrated with examples from real-world case studies. We mention moving sensor platforms (e.g. towed acoustics), but then focus on methods involving sensors at fixed locations, particularly hydrophones to survey marine mammals, as acoustic-based density estimation research to date has been concentrated in this area. Primary among these are methods based on distance sampling and spatially explicit capture-recapture. The methods are also applicable to other aquatic and terrestrial sound-producing taxa. We conclude that, despite being in its infancy, density estimation based on passive acoustic data likely will become an important method for surveying a number of diverse taxa, such as sea mammals, fish, birds, amphibians, and insects, especially in situations where inferences are required over long periods of time. There is considerable work ahead, with several potentially fruitful research areas, including the development of (i) hardware and software for data acquisition, (ii) efficient, calibrated, automated detection and classification systems, and (iii) statistical approaches optimized for this application. Further, survey design will need to be developed, and research is needed on the acoustic behaviour of target species. Fundamental research on vocalization rates and group sizes, and the relation between these and other factors such as season or behaviour state, is critical. Evaluation of the methods under known density scenarios will be important for empirically validating the approaches presented here. © 2012 The Authors. Biological Reviews © 2012 Cambridge Philosophical Society.

  5. Estimating animal population density using passive acoustics

    PubMed Central

    Marques, Tiago A; Thomas, Len; Martin, Stephen W; Mellinger, David K; Ward, Jessica A; Moretti, David J; Harris, Danielle; Tyack, Peter L

    2013-01-01

    Reliable estimation of the size or density of wild animal populations is very important for effective wildlife management, conservation and ecology. Currently, the most widely used methods for obtaining such estimates involve either sighting animals from transect lines or some form of capture-recapture on marked or uniquely identifiable individuals. However, many species are difficult to sight, and cannot be easily marked or recaptured. Some of these species produce readily identifiable sounds, providing an opportunity to use passive acoustic data to estimate animal density. In addition, even for species for which other visually based methods are feasible, passive acoustic methods offer the potential for greater detection ranges in some environments (e.g. underwater or in dense forest), and hence potentially better precision. Automated data collection means that surveys can take place at times and in places where it would be too expensive or dangerous to send human observers. Here, we present an overview of animal density estimation using passive acoustic data, a relatively new and fast-developing field. We review the types of data and methodological approaches currently available to researchers and we provide a framework for acoustics-based density estimation, illustrated with examples from real-world case studies. We mention moving sensor platforms (e.g. towed acoustics), but then focus on methods involving sensors at fixed locations, particularly hydrophones to survey marine mammals, as acoustic-based density estimation research to date has been concentrated in this area. Primary among these are methods based on distance sampling and spatially explicit capture-recapture. The methods are also applicable to other aquatic and terrestrial sound-producing taxa. We conclude that, despite being in its infancy, density estimation based on passive acoustic data likely will become an important method for surveying a number of diverse taxa, such as sea mammals, fish, birds, amphibians, and insects, especially in situations where inferences are required over long periods of time. There is considerable work ahead, with several potentially fruitful research areas, including the development of (i) hardware and software for data acquisition, (ii) efficient, calibrated, automated detection and classification systems, and (iii) statistical approaches optimized for this application. Further, survey design will need to be developed, and research is needed on the acoustic behaviour of target species. Fundamental research on vocalization rates and group sizes, and the relation between these and other factors such as season or behaviour state, is critical. Evaluation of the methods under known density scenarios will be important for empirically validating the approaches presented here. PMID:23190144

  6. Some Limitations for Early Diagnosis of Congenital Chagas Infection by PCR.

    PubMed

    Volta, Bibiana Julieta; Perrone, Alina Elizabet; Rivero, Rocío; Scollo, Karenina; Bustos, Patricia Laura; Bua, Jacqueline

    2018-04-01

    Trypanosoma cruzi , the causing agent of Chagas disease, can be transmitted to the offspring of infected pregnant women, thus being an epidemiologically important way of parasite transmission in humans. In addition, the migration of infected women from endemic areas to nonendemic countries may export this parasite infection. The diagnosis of congenital Chagas disease relies on the detection of the parasite because maternal antibodies are passively transferred to infants during pregnancy. The diagnosis of congenital infection can also be confirmed by detection of infant-specific anti- T cruzi antibodies at 10 months after delivery. Because early detection of T cruzi infection in newborns allows an efficient trypanocidal treatment and cure, more sensitive molecular techniques such as DNA amplification are being used for a prompt parasitological diagnosis of children born to seropositive mothers. In this report, we describe a diagnosis case of a child congenitally infected with T cruzi who tested negative for parasite detection both by microscopic observation and DNA amplification at 20 days and 6 months after delivery. However, at 7 months of age, a hemoculture was made from the infant's blood, and the infective parasite was finally isolated and classified as T cruzi discrete typing unit I. In a retrospective study, real-time polymerase chain reaction also allowed detecting the parasite but failed to detect any parasite load in earlier control samples. This case report stresses that even when molecular techniques are negative, a long-term follow-up is necessary for the diagnosis of infants congenitally infected with T cruzi . Copyright © 2018 by the American Academy of Pediatrics.

  7. Passive immunization of mice pups through oral immunization of dams with a plant-derived vaccine.

    PubMed

    Walmsley, Amanda M; Kirk, Dwayne D; Mason, Hugh S

    2003-03-03

    Passive immunization plays an important role in protecting young mammals against pathogens before the maturation of their own immune systems. Although many reports have shown active immunization of animals and human through the use of plant-derived vaccines, only one report has given evidence of passive immunization of offspring through oral immunization of parents using plant-derived vaccines. In this case, a challenge alone provided the evidence of passive immunization and the mechanism through which this occurred was not investigated. This report describes the first step in elucidating the mechanism of passive immunization of offspring through actively immunizing the female parent through an orally delivered, plant-derived vaccine. The authors found passive immunization of offspring was caused by transfer of antigen-specific IgG through either transplacental transfer or ingesting colostrum. Future studies will investigate the roles of transplacental antibody transfer and ingesting colostrum in passive immunization and the possible involvement of IgA in this immunization route.

  8. Hysteresis in the Active Oxidation of SiC

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Harder, Bryan J.; Myers, Dwight L.

    2011-01-01

    Si and SiC show both passive oxidation behavior where a protective film of SiO2 forms and active oxidation behavior where a volatile suboxide SiO(g) forms. The active-to-passive and passive-to-active oxidation transitions are explored for both Si and SiC. Si shows a dramatic difference between the P(O2) for the two transitions of 10-4 bar. The active-to-passive transition is controlled by the condition for SiO2/Si equilibrium and the passive-to-active transition is controlled by the decomposition of SiO2. In the case of SiC, the P(O2) for these transitions are much closer. The active-to-passive transition appears to be controlled by the condition for SiO2/SiC equilibrium. The passive-to-active transition appears to be controlled by the interfacial reaction of SiC and SiO2 and subsequent generation of gases at the interface which leads to scale breakdown.

  9. First detection of European bat lyssavirus type 2 (EBLV-2) in Norway.

    PubMed

    Moldal, Torfinn; Vikøren, Turid; Cliquet, Florence; Marston, Denise A; van der Kooij, Jeroen; Madslien, Knut; Ørpetveit, Irene

    2017-07-11

    In Europe, bat rabies is primarily attributed to European bat lyssavirus type 1 (EBLV-1) and European bat lyssavirus type 2 (EBLV-2) which are both strongly host-specific. Approximately thirty cases of infection with EBLV-2 in Daubenton's bats (Myotis daubentonii) and pond bats (M. dasycneme) have been reported. Two human cases of rabies caused by EBLV-2 have also been confirmed during the last thirty years, while natural spill-over to other non-flying mammals has never been reported. Rabies has never been diagnosed in mainland Norway previously. In late September 2015, a subadult male Daubenton's bat was found in a poor condition 800 m above sea level in the southern part of Norway. The bat was brought to the national Bat Care Centre where it eventually displayed signs of neurological disease and died after two days. EBLV-2 was detected in brain tissues by polymerase chain reaction (PCR) followed by sequencing of a part of the nucleoprotein gene, and lyssavirus was isolated in neuroblastoma cells. The detection of EBLV-2 in a bat in Norway broadens the knowledge on the occurrence of this zoonotic agent. Since Norway is considered free of rabies, adequate information to the general public regarding the possibility of human cases of bat-associated rabies should be given. No extensive surveillance of lyssavirus infections in bats has been conducted in the country, and a passive surveillance network to assess rabies prevalence and bat epidemiology is highly desired.

  10. Persistent konzo and cyanogen toxicity from cassava in northern Mozambique.

    PubMed

    Ernesto, Mario; Cardoso, A Paula; Nicala, Domingos; Mirione, Estevão; Massaza, Fernando; Cliff, Julie; Haque, M Rezaul; Bradbury, J Howard

    2002-06-01

    We aimed to detect new cases of konzo and monitor cyanogen exposure from cassava flour in communities previously affected by konzo epidemics in Nampula Province, northern Mozambique. Other objectives were to detect subclinical upper motor neuron damage in schoolchildren and test a new kit to measure urinary thiocyanate concentration. In 1999 and 2000, we carried out active and passive case detection for konzo in Memba and Mogincual Districts. In July and October, 1999, we collected cassava flour from 30 houses in three communities and measured cyanogen concentrations with a picrate kit. In October 1999, we examined all schoolchildren in three communities for ankle clonus and measured urinary thiocyanate concentration in thirty schoolchildren in each of five communities with a picrate kit. We found 27 new cases of konzo in Mogincual District. Mean total cyanogen concentrations in cassava flour varied between both seasons and years, but were always high, ranging from 26 to 186 ppm. Very high mean levels at three sites in November 1998 and July 1999 were probably due to low rainfall in the 1997-1998 season. The proportion of schoolchildren with ankle clonus varied from 8 to 17%. The new picrate kit for urinary thiocyanate worked well; mean concentrations in schoolchildren ranged from 225 to 384 micromol x l(-1). Konzo and sub-clinical upper motor neuron damage persist in poor rural communities in northern Mozambique, associated with high cyanogen concentrations in cassava flour and high urinary thiocyanate concentrations in schoolchildren.

  11. The Acute Effect of Cryotherapy on Muscle Strength and Shoulder Proprioception.

    PubMed

    Torres, Rui; Silva, Filipa; Pedrosa, Vera; Ferreira, João; Lopes, Alexandre

    2017-11-01

    Cryotherapy, a common intervention used by clinicians, poses several benefits in managing acute injuries. However, cooling muscle tissue can interfere with muscular properties and the sensory-motor system. The aim of this study was to analyze the influence of cryotherapy with a crushed-ice pack on shoulder proprioception concerning joint position sense, force sense, the threshold for detecting passive movement, and maximal force production. A randomized, double-blind controlled trial. 48 healthy women aged 22.6 ± 0.4 y with a mean body mass index of 22.8 ±0.37 kg/m2 and a percentage of body fat of 15.4 ± 1.5%. In the experimental group, a crushed-ice pack was applied to the shoulder for 15 min, whereas participants in the control group applied a sandbag at skin temperature, also for 15 min. An isokinetic dynamometer was used to assess maximal voluntary contraction, force sense, joint position sense, and the threshold for detecting passive movement. Paired sample t tests revealed that maximal voluntary isometric contraction decreased significantly after cryotherapy (P ≤ .001), or approximately 10% of the reduction found in both muscular groups assessed. Shoulder position sense (P < .001) and the threshold for detecting passive movement (P = .01 and P = .01 for lateral and medial shoulder rotator muscles, respectively) also suffered significant impairment. Nevertheless, no significant differences emerged in force sense at 20% and 50% of maximal force reproduction (P = .41 and P = .10 for lateral rotator muscles at 20% and 50%, respectively; and P = .20 and P = .09 for medial rotator muscles at 20% and 50%, respectively). Applying a crushed-ice pack to the shoulder for 15 min negatively affected muscle strength and impaired shoulder proprioception by decreasing joint position sense and the threshold for detecting passive movement.

  12. Passive MIMO Radar Detection

    DTIC Science & Technology

    2013-09-01

    investigated using recent results from random matrix theory. Equivalence is established between PMR networks without direct-path signals and passive...approach ignores a potentially useful source of information about the unknown transmit signals . This is particularly true in high-DNR scenarios, in...which the direct-path signal provides a high-quality reference that can be used for (noisy) matched filtering, as in the conventional approach. Thus

  13. Learned Helplessness at Fifty: Insights from Neuroscience

    PubMed Central

    Maier, Steven F.; Seligman, Martin E. P.

    2016-01-01

    Learned helplessness, the failure to escape shock induced by uncontrollable aversive events, was discovered half a century ago. Seligman and Maier (1967) theorized that animals learned that outcomes were independent of their responses—that nothing they did mattered – and that this learning undermined trying to escape. The mechanism of learned helplessness is now very well-charted biologically and the original theory got it backwards. Passivity in response to shock is not learned. It is the default, unlearned response to prolonged aversive events and it is mediated by the serotonergic activity of the dorsal raphe nucleus, which in turn inhibits escape. This passivity can be overcome by learning control, with the activity of the medial prefrontal cortex, which subserves the detection of control leading to the automatic inhibition of the dorsal raphe nucleus. So animals learn that they can control aversive events, but the passive failure to learn to escape is an unlearned reaction to prolonged aversive stimulation. In addition, alterations of the ventromedial prefrontal cortex-dorsal raphe pathway can come to subserve the expectation of control. We speculate that default passivity and the compensating detection and expectation of control may have substantial implications for how to treat depression. PMID:27337390

  14. Learned helplessness at fifty: Insights from neuroscience.

    PubMed

    Maier, Steven F; Seligman, Martin E P

    2016-07-01

    Learned helplessness, the failure to escape shock induced by uncontrollable aversive events, was discovered half a century ago. Seligman and Maier (1967) theorized that animals learned that outcomes were independent of their responses-that nothing they did mattered-and that this learning undermined trying to escape. The mechanism of learned helplessness is now very well-charted biologically, and the original theory got it backward. Passivity in response to shock is not learned. It is the default, unlearned response to prolonged aversive events and it is mediated by the serotonergic activity of the dorsal raphe nucleus, which in turn inhibits escape. This passivity can be overcome by learning control, with the activity of the medial prefrontal cortex, which subserves the detection of control leading to the automatic inhibition of the dorsal raphe nucleus. So animals learn that they can control aversive events, but the passive failure to learn to escape is an unlearned reaction to prolonged aversive stimulation. In addition, alterations of the ventromedial prefrontal cortex-dorsal raphe pathway can come to subserve the expectation of control. We speculate that default passivity and the compensating detection and expectation of control may have substantial implications for how to treat depression. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. A complete passive blind image copy-move forensics scheme based on compound statistics features.

    PubMed

    Peng, Fei; Nie, Yun-ying; Long, Min

    2011-10-10

    Since most sensor pattern noise based image copy-move forensics methods require a known reference sensor pattern noise, it generally results in non-blinded passive forensics, which significantly confines the application circumstances. In view of this, a novel passive-blind image copy-move forensics scheme is proposed in this paper. Firstly, a color image is transformed into a grayscale one, and wavelet transform based de-noising filter is used to extract the sensor pattern noise, then the variance of the pattern noise, the signal noise ratio between the de-noised image and the pattern noise, the information entropy and the average energy gradient of the original grayscale image are chosen as features, non-overlapping sliding window operations are done to the images to divide them into different sub-blocks. Finally, the tampered areas are detected by analyzing the correlation of the features between the sub-blocks and the whole image. Experimental results and analysis show that the proposed scheme is completely passive-blind, has a good detection rate, and is robust against JPEG compression, noise, rotation, scaling and blurring. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. Prevalence of human malaria infection in Pakistani areas bordering with Iran.

    PubMed

    Yasinzai, Mohammad Iqbal; Kakarsulemankhel, Juma Khan

    2013-03-01

    To study the prevalence of malarial infections in human population of district Panjgur in south-western Pakistan. The cross-sectional study identified malarial parasites in the blood slides of 6119 suspected malaria patients from July 2006 to June 2008 through passive and active case detection methods. SPSS 11 was used for statistical analysis. Out of 6119 suspected cases of malaria, 2346 (38.3%) were found to be positive for malarial parasite on blood smear slides. Of these, 1868 (79.6%) cases were due to Plasmodium vivax infection, and 478 (20.3%) had P. falciparum. However, seasonal variation was also noted: P. vivax infection was the highest (n = 131/144, 90.9%) in November and the lowest (n=83/176, 47.1%) in October. The prevalence was higher (n=1831, 78%) in males. Age-wise, the prevalence of the disease was 81.2% (n=334) and 80% (n=860) for age groups 1-10 years and 11-20 years. No case of P. malariae and P. ovale was detected in the study period. No association was found between types of infection and age groups. Human malaria infection was quite frequent in the study region, which is one of the hottest areas of Balochistan, Pakistan. In clinically-suspected cases of malaria, there was a high slide positivity rate. The high prevalence rate of P. vivax poses a significant health hazard but R falciparum also may lead to serious complications, including cerebral malaria.

  17. Improved pulse shape discriminator for fast neutron-gamma ray detection system

    NASA Technical Reports Server (NTRS)

    Lockwood, J. A.; St. Onge, R.

    1969-01-01

    Discriminator in nuclear particle detection system distinguishes nuclear particle type and energy among many different nuclear particles. Discriminator incorporates passive, linear circuit elements so that it will operate over a wide dynamic range.

  18. Occurrence and seasonal distribution of polycyclic aromatic hydrocarbons and legacy and current-use pesticides in air from a Mediterranean coastal lagoon (Mar Menor, SE Spain).

    PubMed

    Carratalá, A; Moreno-González, R; León, V M

    2017-01-01

    The occurrence and seasonal distribution of polycyclic aromatic hydrocarbons (PAHs) and legacy and current-use pesticides (CUPs) in air were characterized around the Mar Menor lagoon using both active and passive sampling devices. The seasonal distribution of these pollutants was determined at 6 points using passive samplers. Passive sampler sampling rates were estimated for all detected analytes using an active sampler, considering preferentially winter data, due to probable losses in active sampling during summer (high temperatures and solar irradiation). The presence of 28 compounds (14 CUPs, 11 PAHs and 3 organochlorinated pesticides) were detected in air by polyurethane passive sampling. The most commonly detected contaminants (>95% of samples) in air were chlorpyrifos, chlorpyrifos-methyl and phenanthrene. The maximum concentrations corresponded to phenanthrene (6000 pg m -3 ) and chlorpyrifos (4900 pg m -3 ). The distribution of contaminants was spatially and seasonally heterogeneous. The highest concentrations of PAHs were found close to the airport, while the highest concentrations of pesticides were found in the influence area of agricultural fields (western stations). PAH and herbicide concentrations were higher in winter than in the other seasons, although some insecticides such as chlorpyrifos were more abundant in autumn. The presence of PAHs and legacy and current-use pesticides in air confirmed their transference potential to marine coastal areas such as the Mar Menor lagoon. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Strain Wave Acquisition by a Fiber Optic Coherent Sensor for Impact Monitoring

    PubMed Central

    Sbarufatti, Claudio; Beligni, Alessio; Gilioli, Andrea; Ferrario, Maddalena; Mattarei, Marco; Martinelli, Mario; Giglio, Marco

    2017-01-01

    A novel fiber optic sensing technology for high frequency dynamics detection is proposed in this paper, specifically tailored for structural health monitoring applications based on strain wave analysis, for both passive impact identification and active Lamb wave monitoring. The sensing solution relies on a fiber optic-based interferometric architecture associated to an innovative coherent detection scheme, which retrieves in a completely passive way the high-frequency phase information of the received optical signal. The sensing fiber can be arranged into different layouts, depending on the requirement of the specific application, in order to enhance the sensor sensitivity while still ensuring a limited gauge length if punctual measures are required. For active Lamb wave monitoring, this results in a sensing fiber arranged in multiple loops glued on an aluminum thin panel in order to increase the phase signal only in correspondence to the sensing points of interest. Instead, for passive impact identification, the required sensitivity is guaranteed by simply exploiting a longer gauge length glued to the structure. The fiber optic coherent (FOC) sensor is exploited to detect the strain waves emitted by a piezoelectric transducer placed on the aluminum panel or generated by an impulse hammer, respectively. The FOC sensor measurements have been compared with both a numerical model based on Finite Elements and traditional piezoelectric sensors, confirming a good agreement between experimental and simulated results for both active and passive impact monitoring scenarios. PMID:28773154

  20. Ultra-fast photon counting with a passive quenching silicon photomultiplier in the charge integration regime

    NASA Astrophysics Data System (ADS)

    Zhang, Guoqing; Lina, Liu

    2018-02-01

    An ultra-fast photon counting method is proposed based on the charge integration of output electrical pulses of passive quenching silicon photomultipliers (SiPMs). The results of the numerical analysis with actual parameters of SiPMs show that the maximum photon counting rate of a state-of-art passive quenching SiPM can reach ~THz levels which is much larger than that of the existing photon counting devices. The experimental procedure is proposed based on this method. This photon counting regime of SiPMs is promising in many fields such as large dynamic light power detection.

  1. Passive Polarimetric Information Processing for Target Classification

    NASA Astrophysics Data System (ADS)

    Sadjadi, Firooz; Sadjadi, Farzad

    Polarimetric sensing is an area of active research in a variety of applications. In particular, the use of polarization diversity has been shown to improve performance in automatic target detection and recognition. Within the diverse scope of polarimetric sensing, the field of passive polarimetric sensing is of particular interest. This chapter presents several new methods for gathering in formation using such passive techniques. One method extracts three-dimensional (3D) information and surface properties using one or more sensors. Another method extracts scene-specific algebraic expressions that remain unchanged under polariza tion transformations (such as along the transmission path to the sensor).

  2. X ray screening at entry and systematic screening for the control of tuberculosis in a highly endemic prison.

    PubMed

    Sanchez, Alexandra; Massari, Veronique; Gerhardt, Germano; Espinola, Ana Beatriz; Siriwardana, Mahinda; Camacho, Luiz Antonio B; Larouzé, Bernard

    2013-10-20

    Tuberculosis (TB) is a major issue in prisons of low and middle income countries where TB incidence rates are much higher in prison populations as compared with the general population. In the Rio de Janeiro (RJ) State prison system, the TB control program is limited to passive case-finding and supervised short duration treatment. The aim of this study was to measure the impact of X-ray screening at entry associated with systematic screening on the prevalence and incidence of active TB. We followed up for 2 years a RJ State prison for adult males (1429 inmates at the beginning of the study) and performed, in addition to passive case-finding, 1) two "cross-sectional" X-ray systematic screenings: the first at the beginning of the study period and the second 13 months later; 2) X-ray screening of inmates entering the prison during the 2 year study period. Bacteriological examinations were performed in inmates presenting any pulmonary, pleural or mediastinal X-ray abnormality or spontaneously attending the prison clinic for symptoms suggestive of TB. Overall, 4326 X-rays were performed and 246 TB cases were identified. Prevalence among entering inmates remained similar during 1st and the 2nd year of the study: 2.8% (21/754) and 2.9% (28/954) respectively, whereas prevalence decreased from 6.0% (83/1374) to 2.8% (35/1244) between 1st and 2nd systematic screenings (p < 0.0001). Incidence rates of cases identified by passive case-finding decreased from 42 to 19 per 1000 person-years between the 1st and the 2nd year (p < 0.0001). Cases identified by screenings were less likely to be bacteriologically confirmed as compared with cases identified by passive-case finding. The strategy investigated, which seems highly effective, should be considered in highly endemic confined settings such as prisons.

  3. Association between environmental tobacco smoke exposure and lung cancer susceptibility: modification by antioxidant enzyme genetic polymorphisms.

    PubMed

    Fathy, Mona; Hamed, Mai; Youssif, Omnia; Fawzy, Nahla; Ashour, Wafa

    2014-02-01

    Environmental tobacco smoke (ETS) is the primary etiologic factor responsible for lung cancer. However, only 10-15 % of smokers develop lung cancer, suggesting a genetic role in modifying individual susceptibility to lung cancer. Antioxidant enzymes and genetic polymorphisms should be considered. The present study aimed to evaluate the role of antioxidant enzyme activity and genetic polymorphisms in modifying the susceptibility to lung cancer among individuals exposed to ETS. A total of 150 male subjects were divided into three groups: 50 lung cancer patients, 50 chronic smokers, and 50 passive smokers. Genotyping of microsomal epoxide hydrolase (mEH) exon 3 (Tyr(113)Hist) and exon 4 (Hist(139)Arg) polymorphisms were done by the polymerase chain reaction-restriction fragment length polymorphism technique. MnSOD (Val(16)Ala) polymorphism was detected by the real time-TaqMan assay. Erythrocyte MnSOD activity was measured spectrophotometrically. ETS-exposed individuals (both active and passive smokers) who carried the His allele of mEH exon3 have a 2.9-fold increased risk of lung cancer (odds ratio [OR] 2.9, P < 0.001). In addition, ETS-exposed carriers of the Arg allele of mEH exon 4 have a 2.1-fold increased risk of lung cancer (OR 2.1, P = 0.024). However, no association between the MnSOD Val(16)Ala polymorphism and lung cancer was detected among ETS-exposed individuals (OR 1.6, P = 0.147), although the lung cancer group had significantly lower MnSOD activity than the chronic or passive smoker groups (P = 0.03). Exons 3 and 4 polymorphisms of the mEH gene may contribute to lung cancer susceptibility through disturbed antioxidant balance. However, this was not the case with the MnSOD Val(16)Ala single-nucleotid polymorphism. Antioxidant enzymes may modulate the influence of ETS exposure on lung cancer risk.

  4. Passive Optical Link Budget for LEO Space Surveillance

    NASA Astrophysics Data System (ADS)

    Wagner, P.; Hasenohr, T.; Hampf, D.; Sproll, F.; Humbert, L.; Rodmann, J.; Riede, W.

    The rising space debris population is becoming an increasing risk for space assets. Even objects with the size of 10mm can cause major damages to active spacecraft. Especially the orbits around 800km high are densely populated with space debris objects. To assess the risk of collisions with active satellites, the Earth orbits need to be surveyed permanently. Space debris laser ranging systems for example can deliver highly accurate positional data for precise orbit determination. Therefor a priori information about the objects coarse trajectory is needed. Such initial orbit information can be provided by wide angle optical sensors. The Institute of Technical Physics at the German Aerospace Center in Stuttgart runs an observatory to perform passive as well as laser optical measurements to LEO objects. In order to detect unknown objects, a wide-angle imaging system with a field of view in the range of 5° to 15° equipped with an astronomical CCD camera and a commercial off the shelf (COTS) lens was designed to continuously observe the night sky for LEO objects. This paper presents the passive optical link budget for observing LEO objects to show the benefits and limits of the physical performance of an optical surveillance system. A compact COTS system is able to detect objects with a couple of decimeters in size while a large aperture telescope can detect objects with diameters below 10cm. Additionally, data captured by a passive optical staring system with a 10 cm aperture was analyzed. It is shown that 90% of all objects with a radar cross section larger than 2m² are detected with such a system during twilight conditions. The smallest detected LEO object with this system has a size of 0.32m x 0.32m x 0.26m. These measurements are compared to the developed link budget which allows an estimation of the performance of larger systems.

  5. Virus-Specific Differences in Rates of Disease during the 2010 Dengue Epidemic in Puerto Rico

    PubMed Central

    Sharp, Tyler M.; Hunsperger, Elizabeth; Santiago, Gilberto A.; Muñoz-Jordan, Jorge L.; Santiago, Luis M.; Rivera, Aidsa; Rodríguez-Acosta, Rosa L.; Gonzalez Feliciano, Lorenzo; Margolis, Harold S.; Tomashek, Kay M.

    2013-01-01

    Background Dengue is a potentially fatal acute febrile illness (AFI) caused by four mosquito-transmitted dengue viruses (DENV-1–4) that are endemic in Puerto Rico. In January 2010, the number of suspected dengue cases reported to the passive dengue surveillance system exceeded the epidemic threshold and an epidemic was declared soon after. Methodology/Principal Findings To characterize the epidemic, surveillance and laboratory diagnostic data were compiled. A suspected case was a dengue-like AFI in a person reported by a health care provider with or without a specimen submitted for diagnostic testing. Laboratory-positive cases had: (i) DENV nucleic acid detected by reverse transcriptase-polymerase chain reaction (RT-PCR) in an acute serum specimen; (ii) anti-DENV IgM antibody detected by ELISA in any serum specimen; or (iii) DENV antigen or nucleic acid detected in an autopsy-tissue specimen. In 2010, a total of 26,766 suspected dengue cases (7.2 per 1,000 residents) were identified, of which 46.6% were laboratory-positive. Of 7,426 RT-PCR-positive specimens, DENV-1 (69.0%) and DENV-4 (23.6%) were detected more frequently than DENV-2 (7.3%) and DENV-3 (<0.1%). Nearly half (47.1%) of all laboratory-positive cases were adults, 49.7% had dengue with warning signs, 11.1% had severe dengue, and 40 died. Approximately 21% of cases were primary DENV infections, and 1–4 year olds were the only age group for which primary infection was more common than secondary. Individuals infected with DENV-1 were 4.2 (95% confidence interval [CI]: 1.7–9.8) and 4.0 (95% CI: 2.4–6.5) times more likely to have primary infection than those infected with DENV-2 or -4, respectively. Conclusions/Significance This epidemic was long in duration and yielded the highest incidence of reported dengue cases and deaths since surveillance began in Puerto Rico in the late 1960's. This epidemic re-emphasizes the need for more effective primary prevention interventions to reduce the morbidity and mortality of dengue. PMID:23593526

  6. Passivity analysis for uncertain BAM neural networks with time delays and reaction-diffusions

    NASA Astrophysics Data System (ADS)

    Zhou, Jianping; Xu, Shengyuan; Shen, Hao; Zhang, Baoyong

    2013-08-01

    This article deals with the problem of passivity analysis for delayed reaction-diffusion bidirectional associative memory (BAM) neural networks with weight uncertainties. By using a new integral inequality, we first present a passivity condition for the nominal networks, and then extend the result to the case with linear fractional weight uncertainties. The proposed conditions are expressed in terms of linear matrix inequalities, and thus can be checked easily. Examples are provided to demonstrate the effectiveness of the proposed results.

  7. Technology Solutions for New Homes Case Study: Columbia County Habitat for Humanity Passive Townhomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-04-01

    The Columbia County (New York) Habitat for Humanity (Columbia County Habitat) affiliate has been experimenting with high-performance building since 2012, starting with ENERGY STAR® Certified Homes. In 2013, they constructed their first homes aimed at the Passive House standards. Building off of this effort, in 2014 they began work on a second set of Passive Townhomes in Hudson, New York, in partnership with the Advanced Residential Integrated Energy Solutions (ARIES) Building America team and BarlisWedlick Architects.

  8. Technology Solutions Case Study: Design Guidance for Passive Vents in New Construction, Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    In an effort to improve indoor air quality in high-performance, new construction, multifamily buildings, dedicated sources of outdoor air are being implemented. Passive vents are being selected by some design teams over other strategies because of their lower first costs and operating costs. The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings constructed eight steps, which outline the design and commissioning required for these passive vents to perform as intended.

  9. National Transportation Safety Board Safety Study: Safety At Passive Grade Crossings. Volume 2: Case Summaries

    DOT National Transportation Integrated Search

    1998-07-07

    More than 4,000 accidents have occurred at the nation's active and passive grade crossings each year from 1991 through 1996. Many of the accidents at active crossings have involved highway vehicle drivers who did not comply with train-activated warni...

  10. Counseling Practice: In Defense of Passive Modes of Professional Engagement

    ERIC Educational Resources Information Center

    Hansen, James T.

    2010-01-01

    Historically, passive ideologies of counseling have regularly morphed into active approaches. The author contends that professional power and status are the underlying motives for this ideological transition. Based on empirical findings and recent philosophical developments, a case is made for the counseling profession to revalue passive…

  11. Detection Thresholds of Falling Snow from Satellite-Borne Active and Passive Sensors

    NASA Technical Reports Server (NTRS)

    Skofronick-Jackson, Gail; Johnson, Benjamin T.; Munchak, S. Joseph

    2012-01-01

    Precipitation, including rain and snow, is a critical part of the Earth's energy and hydrology cycles. Precipitation impacts latent heating profiles locally while global circulation patterns distribute precipitation and energy from the equator to the poles. For the hydrological cycle, falling snow is a primary contributor in northern latitudes during the winter seasons. Falling snow is the source of snow pack accumulations that provide fresh water resources for many communities in the world. Furthermore, falling snow impacts society by causing transportation disruptions during severe snow events. In order to collect information on the complete global precipitation cycle, both liquid and frozen precipitation must be collected. The challenges of estimating falling snow from space still exist though progress is being made. These challenges include weak falling snow signatures with respect to background (surface, water vapor) signatures for passive sensors over land surfaces, unknowns about the spherical and non-spherical shapes of the snowflakes, their particle size distributions (PSDs) and how the assumptions about the unknowns impact observed brightness temperatures or radar reflectivities, differences in near surface snowfall and total column snow amounts, and limited ground truth to validate against. While these challenges remain, knowledge of their impact on expected retrieval results is an important key for understanding falling snow retrieval estimations. Since falling snow from space is the next precipitation measurement challenge from space, information must be determined in order to guide retrieval algorithm development for these current and future missions. This information includes thresholds of detection for various sensor channel configurations, snow event system characteristics, snowflake particle assumptions, and surface types. For example, can a lake effect snow system with low (approx 2.5 km) cloud tops having an ice water content (IWC) at the surface of 0.25 g / cubic m and dendrite snowflakes be detected? If this information is known, we can focus retrieval efforts on detectable storms and concentrate advances on achievable results. Here, the focus is to determine thresholds of detection for falling snow for various snow conditions over land and lake surfaces. The results rely on simulated Weather Research Forecasting (WRF) simulations of falling snow cases since simulations provide all the information to determine the measurements from space and the ground truth. Sensitivity analyses were performed to better ascertain the relationships between multifrequency microwave and millimeter-wave sensor observations and the falling snow/underlying field of view. In addition, thresholds of detection for various sensor channel configurations, snow event system characteristics, snowflake particle assumptions, and surface types were studied. Results will be presented for active radar at Ku, Ka, and W-band and for passive radiometer channels from 10 to 183 GHz.

  12. A Novel Displacement and Tilt Detection Method Using Passive UHF RFID Technology.

    PubMed

    Lai, Xiaozheng; Cai, Zhirong; Xie, Zeming; Zhu, Hailong

    2018-05-21

    The displacement and tilt angle of an object are useful information for wireless monitoring applications. In this paper, a low-cost detection method based on passive radio frequency identification (RFID) technology is proposed. This method uses a standard ultrahigh-frequency (UHF) RFID reader to measure the phase variation of the tag response and detect the displacement and tilt angle of RFID tags attached to the targeted object. An accurate displacement result can be detected by the RFID system with a linearly polarized (LP) reader antenna. Based on the displacement results, an accurate tilt angle can also be detected by the RFID system with a circularly polarized (CP) reader antenna, which has been proved to have a linear relationship with the phase parameter of the tag’s backscattered wave. As far as accuracy is concerned, the mean absolute error (MAE) of displacement is less than 2 mm and the MAE of the tilt angle is less than 2.5° for an RFID system with 500 mm working range.

  13. Unmanned Ground Vehicle Perception Using Thermal Infrared Cameras

    NASA Technical Reports Server (NTRS)

    Rankin, Arturo; Huertas, Andres; Matthies, Larry; Bajracharya, Max; Assad, Christopher; Brennan, Shane; Bellutta, Paolo; Sherwin, Gary W.

    2011-01-01

    The ability to perform off-road autonomous navigation at any time of day or night is a requirement for some unmanned ground vehicle (UGV) programs. Because there are times when it is desirable for military UGVs to operate without emitting strong, detectable electromagnetic signals, a passive only terrain perception mode of operation is also often a requirement. Thermal infrared (TIR) cameras can be used to provide day and night passive terrain perception. TIR cameras have a detector sensitive to either mid-wave infrared (MWIR) radiation (3-5?m) or long-wave infrared (LWIR) radiation (8-12?m). With the recent emergence of high-quality uncooled LWIR cameras, TIR cameras have become viable passive perception options for some UGV programs. The Jet Propulsion Laboratory (JPL) has used a stereo pair of TIR cameras under several UGV programs to perform stereo ranging, terrain mapping, tree-trunk detection, pedestrian detection, negative obstacle detection, and water detection based on object reflections. In addition, we have evaluated stereo range data at a variety of UGV speeds, evaluated dual-band TIR classification of soil, vegetation, and rock terrain types, analyzed 24 hour water and 12 hour mud TIR imagery, and analyzed TIR imagery for hazard detection through smoke. Since TIR cameras do not currently provide the resolution available from megapixel color cameras, a UGV's daytime safe speed is often reduced when using TIR instead of color cameras. In this paper, we summarize the UGV terrain perception work JPL has performed with TIR cameras over the last decade and describe a calibration target developed by General Dynamics Robotic Systems (GDRS) for TIR cameras and other sensors.

  14. Flow microcapillary plasma mass spectrometry-based investigation of new Al-Cr-Fe complex metallic alloy passivation.

    PubMed

    Ott, N; Beni, A; Ulrich, A; Ludwig, C; Schmutz, P

    2014-03-01

    Al-Cr-Fe complex metallic alloys are new intermetallic phases with low surface energy, low friction, and high corrosion resistance down to very low pH values (0-2). Flow microcapillary plasma mass spectrometry under potentiostatic control was used to characterize the dynamic aspect of passivation of an Al-Cr-Fe gamma phase in acidic electrolytes, allowing a better insight on the parameters inducing chemical stability at the oxyhydroxide-solution interface. In sulfuric acid pH 0, low element dissolution rates (in the µg cm(-2) range after 60 min) evidenced the passive state of the Al-Cr-Fe gamma phase with a preferential over-stoichiometric dissolution of Al and Fe cations. Longer air-aging was found to be beneficial for stabilizing the passive film. In chloride-containing electrolytes, ten times higher Al dissolution rates were detected at open-circuit potential (OCP), indicating that the spontaneously formed passive film becomes unstable. However, electrochemical polarization at low passive potentials induces electrical field generated oxide film modification, increasing chemical stability at the oxyhydroxide-solution interface. In the high potential passive region, localized attack is initiated with subsequent active metal dissolution. © 2013 Published by Elsevier B.V.

  15. High sensitivity broadband 360GHz passive receiver for TeraSCREEN

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Oldfield, Matthew; Maestrojuán, Itziar; Platt, Duncan; Brewster, Nick; Viegas, Colin; Alderman, Byron; Ellison, Brian N.

    2016-05-01

    TeraSCREEN is an EU FP7 Security project aimed at developing a combined active, with frequency channel centered at 360 GHz, and passive, with frequency channels centered at 94, 220 and 360 GHz, imaging system for border controls in airport and commercial ferry ports. The system will include automatic threat detection and classification and has been designed with a strong focus on the ethical, legal and practical aspects of operating in these environments and with the potential threats in mind. Furthermore, both the passive and active systems are based on array receivers with the active system consisting of a 16 element MIMO FMCW radar centered at 360 GHz with a bandwidth of 30 GHz utilizing a custom made direct digital synthesizer. The 16 element passive receiver system at 360 GHz uses commercial Gunn diode oscillators at 90 GHz followed by custom made 90 to 180 GHz frequency doublers supplying the local oscillator for 360 GHz sub-harmonic mixers. This paper describes the development of the passive antenna module, local oscillator chain, frequency mixers and detectors used in the passive receiver array of this system. The complete passive receiver chain is characterized in this paper.

  16. Distress detection, location, and communications using advanced space technology. [satellite-borne synthetic aperture radar

    NASA Technical Reports Server (NTRS)

    Sivertson, W. E., Jr.

    1977-01-01

    This paper briefly introduces a concept for low-cost, global, day-night, all-weather disaster warning and assistance. Evolving, advanced space technology with passive radio frequency reflectors in conjunction with an imaging synthetic aperture radar is employed to detect, identify, locate, and provide passive communication with earth users in distress. This concept evolved from a broad NASA research on new global search and rescue techniques. Appropriate airborne radar test results from this research are reviewed and related to potential disaster applications. The analysis indicates the approach has promise for disaster communications relative to floods, droughts, earthquakes, volcanic eruptions, and severe storms.

  17. Last call: Passive acoustic monitoring shows continued rapid decline of critically endangered vaquita.

    PubMed

    Thomas, Len; Jaramillo-Legorreta, Armando; Cardenas-Hinojosa, Gustavo; Nieto-Garcia, Edwyna; Rojas-Bracho, Lorenzo; Ver Hoef, Jay M; Moore, Jeffrey; Taylor, Barbara; Barlow, Jay; Tregenza, Nicholas

    2017-11-01

    The vaquita is a critically endangered species of porpoise. It produces echolocation clicks, making it a good candidate for passive acoustic monitoring. A systematic grid of sensors has been deployed for 3 months annually since 2011; results from 2016 are reported here. Statistical models (to compensate for non-uniform data loss) show an overall decline in the acoustic detection rate between 2015 and 2016 of 49% (95% credible interval 82% decline to 8% increase), and total decline between 2011 and 2016 of over 90%. Assuming the acoustic detection rate is proportional to population size, approximately 30 vaquita (95% credible interval 8-96) remained in November 2016.

  18. Kinesthetic deficit in children with developmental coordination disorder.

    PubMed

    Li, Kuan-yi; Su, Wei-jen; Fu, Hsuan-wei; Pickett, Kristen A

    2015-03-01

    The aim of this study was to measure and compare kinesthetic sensitivity in children with developmental coordination disorder (DCD) and typically developing (TD) children between 6 and 11 years old. 30 children with DCD aged 6 to 11 years (5 in each age group) and 30 TD children participated in the study. Participants placed their forearms on a passive motion apparatus which extended the elbow joint at constant velocities between 0.15 and 1.35°s(-1). Participants were required to concentrate on detection of passive arm motion and press a trigger held in their left hand once they sensed it. The detection time was measured for each trial. The DCD group was significantly less sensitive in detection of passive motion than TD children. Further analysis of individual age groups revealed that kinesthetic sensitivity was worse in DCD than TD children for age groups beyond six years of age. Our findings suggested that individual with DCD lag behind their TD counterparts in kinesthetic sensitivity. Between the ages of 7 and 11 years the difference between groups is quantifiable and significant with 11 year old children with DCD performing similar to 7 year old TD children. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Sensitive detection of chemical agents and toxic industrial chemicals using active open-path FTIRs

    NASA Astrophysics Data System (ADS)

    Walter, William T.

    2004-03-01

    Active open-path FTIR sensors provide more sensitive detection of chemical agents than passive FTIRs, such as the M21 RSCAAL and JSLSCAD, and at the same time identify and quantify toxic industrial chemicals (TIC). Passive FTIRs are bistatic sensors relying on infrared sources of opportunity. Utilization of earth-based sources of opportunity limits the source temperatures available for passive chemical-agent FTIR sensors to 300° K. Active FTIR chemical-agent sensors utilize silicon carbide sources, which can be operated at 1500° K. The higher source temperature provides more than an 80-times increase in the infrared radiant flux emitted per unit area in the 7 to 14 micron spectral fingerprint region. Minimum detection limits are better than 5 μgm/m3 for GA, GB, GD, GF and VX. Active FTIR sensors can (1) assist first responders and emergency response teams in their assessment of and reaction to a terrorist threat, (2) provide information on the identification of the TIC present and their concentrations and (3) contribute to the understanding and prevention of debilitating disorders analogous to the Gulf War Syndrome for military and civilian personnel.

  20. Passive monitoring for near surface void detection using traffic as a seismic source

    NASA Astrophysics Data System (ADS)

    Zhao, Y.; Kuzma, H. A.; Rector, J.; Nazari, S.

    2009-12-01

    In this poster we present preliminary results based on our several field experiments in which we study seismic detection of voids using a passive array of surface geophones. The source of seismic excitation is vehicle traffic on nearby roads, which we model as a continuous line source of seismic energy. Our passive seismic technique is based on cross-correlation of surface wave fields and studying the resulting power spectra, looking for "shadows" caused by the scattering effect of a void. High frequency noise masks this effect in the time domain, so it is difficult to see on conventional traces. Our technique does not rely on phase distortions caused by small voids because they are generally too tiny to measure. Unlike traditional impulsive seismic sources which generate highly coherent broadband signals, perfect for resolving phase but too weak for resolving amplitude, vehicle traffic affords a high power signal a frequency range which is optimal for finding shallow structures. Our technique results in clear detections of an abandoned railroad tunnel and a septic tank. The ultimate goal of this project is to develop a technology for the simultaneous imaging of shallow underground structures and traffic monitoring near these structures.

  1. Cetacean population density estimation from single fixed sensors using passive acoustics.

    PubMed

    Küsel, Elizabeth T; Mellinger, David K; Thomas, Len; Marques, Tiago A; Moretti, David; Ward, Jessica

    2011-06-01

    Passive acoustic methods are increasingly being used to estimate animal population density. Most density estimation methods are based on estimates of the probability of detecting calls as functions of distance. Typically these are obtained using receivers capable of localizing calls or from studies of tagged animals. However, both approaches are expensive to implement. The approach described here uses a MonteCarlo model to estimate the probability of detecting calls from single sensors. The passive sonar equation is used to predict signal-to-noise ratios (SNRs) of received clicks, which are then combined with a detector characterization that predicts probability of detection as a function of SNR. Input distributions for source level, beam pattern, and whale depth are obtained from the literature. Acoustic propagation modeling is used to estimate transmission loss. Other inputs for density estimation are call rate, obtained from the literature, and false positive rate, obtained from manual analysis of a data sample. The method is applied to estimate density of Blainville's beaked whales over a 6-day period around a single hydrophone located in the Tongue of the Ocean, Bahamas. Results are consistent with those from previous analyses, which use additional tag data. © 2011 Acoustical Society of America

  2. StopWatch: The preliminary evaluation of a smartwatch-based system for passive detection of cigarette smoking.

    PubMed

    Skinner, Andrew L; Stone, Christopher J; Doughty, Hazel; Munafò, Marcus R

    2018-01-24

    Recent developments in smoking cessation support systems and interventions have highlighted the requirement for unobtrusive, passive ways to measure smoking behaviour. A number of systems have been developed for this that either use bespoke sensing technology, or expensive combinations of wearables and smartphones. Here we present StopWatch, a system for passive detection of cigarette smoking that runs on a low-cost smartwatch and does not require additional sensing or a connected smartphone. Our system uses motion data from the accelerometer and gyroscope in an Android smartwatch to detect the signature hand movements of cigarette smoking. It uses machine learning techniques to transform raw motion data into motion features, and in turn into individual drags and instances of smoking. These processes run on the smartwatch, and do not require a smartphone. We conducted preliminary validations of the system in daily smokers (n=13) in laboratory and free-living conditions running on an Android LG G-Watch. In free-living conditions, over a 24-hour period, the system achieved precision of 86% and recall of 71%. StopWatch is a system for passive measurement of cigarette smoking that runs entirely on a commercially available Android smartwatch. It requires no smartphone so the cost is low, and needs no bespoke sensing equipment so participant burden is also low. Performance is currently lower than other more expensive and complex systems, though adequate for some applications. Future developments will focus on enhancing performance, validation on a range of smartwatches, and detection of electronic cigarette use. We present a low-cost, smartwatch-based system for passive detection of cigarette smoking. It uses data from the motion sensors in the watch to identify the signature hand movements of cigarette smoking. The system will provide the detailed measures of individual smoking behaviour needed for context-triggered just-in-time smoking cessation support systems, and to enable just-in-time adaptive interventions. More broadly, the system will enable researchers to obtain detailed measures of individual smoking behaviour in free-living conditions that are free from the recall errors and reporting biases associated with self-report of smoking. © The Author(s) 2018. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco.

  3. Active sampling technique to enhance chemical signature of buried explosives

    NASA Astrophysics Data System (ADS)

    Lovell, John S.; French, Patrick D.

    2004-09-01

    Deminers and dismounted countermine engineers commonly use metal detectors, ground penetrating radar and probes to locate mines. Many modern landmines have a very low metal content, which severely limits the effectiveness of metal detectors. Canines have also been used for landmine detection for decades. Experiments have shown that canines smell the explosives which are known to leak from most types of landmines. The fact that dogs can detect landmines indicates that vapor sensing is a viable approach to landmine detection. Several groups are currently developing systems to detect landmines by "sniffing" for the ultra-trace explosive vapors above the soil. The amount of material that is available to passive vapor sensing systems is limited to no more than the vapor in equilibrium with the explosive related chemicals (ERCs) distributed in the surface soils over and near the landmine. The low equilibrium vapor pressure of TNT in the soil/atmosphere boundary layer and the limited volume of the boundary layer air imply that passive chemical vapor sensing systems require sensitivities in the picogram range, or lower. ADA is working to overcome many of the limitations of passive sampling methods, by the use of an active sampling method that employs a high-powered (1,200+ joules) strobe lamp to create a highly amplified plume of vapor and/or ERC-bearing fine particulates. Initial investigations have demonstrated that this approach can amplify the detectability of TNT by two or three orders of magnitude. This new active sampling technique could be used with any suitable explosive sensor.

  4. Physical characterization and performance comparison of active- and passive-pixel CMOS detectors for mammography.

    PubMed

    Elbakri, I A; McIntosh, B J; Rickey, D W

    2009-03-21

    We investigated the physical characteristics of two complementary metal oxide semiconductor (CMOS) mammography detectors. The detectors featured 14-bit image acquisition, 50 microm detector element (del) size and an active area of 5 cm x 5 cm. One detector was a passive-pixel sensor (PPS) with signal amplification performed by an array of amplifiers connected to dels via data lines. The other detector was an active-pixel sensor (APS) with signal amplification performed at each del. Passive-pixel designs have higher read noise due to data line capacitance, and the APS represents an attempt to improve the noise performance of this technology. We evaluated the detectors' resolution by measuring the modulation transfer function (MTF) using a tilted edge. We measured the noise power spectra (NPS) and detective quantum efficiencies (DQE) using mammographic beam conditions specified by the IEC 62220-1-2 standard. Our measurements showed the APS to have much higher gain, slightly higher MTF, and higher NPS. The MTF of both sensors approached 10% near the Nyquist limit. DQE values near dc frequency were in the range of 55-67%, with the APS sensor DQE lower than the PPS DQE for all frequencies. Our results show that lower read noise specifications in this case do not translate into gains in the imaging performance of the sensor. We postulate that the lower fill factor of the APS is a possible cause for this result.

  5. Passive Immunotherapy Protects against Enteric Invasion and Lethal Sepsis in a Murine Model of Gastrointestinal Anthrax

    PubMed Central

    Huang, Bruce; Xie, Tao; Rotstein, David; Fang, Hui; Frucht, David M.

    2015-01-01

    The principal portal for anthrax infection in natural animal outbreaks is the digestive tract. Enteric exposure to anthrax, which is difficult to detect or prevent in a timely manner, could be exploited as an act of terror through contamination of human or animal food. Our group has developed a novel animal model of gastrointestinal (GI) anthrax for evaluation of disease pathogenesis and experimental therapeutics, utilizing vegetative Bacillus anthracis (Sterne strain) administered to A/J mice (a complement-deficient strain) by oral gavage. We hypothesized that a humanized recombinant monoclonal antibody (mAb) * that neutralizes the protective antigen (PA) component of B. anthracis lethal toxin (LT) and edema toxin (ET) could be an effective treatment. Although the efficacy of this anti-anthrax PA mAb has been shown in animal models of inhalational anthrax, its activity in GI infection had not yet been ascertained. We hereby demonstrate that passive immunotherapy with anti-anthrax PA mAb, administered at the same time as gastrointestinal exposure to B. anthracis, prevents lethal sepsis in nearly all cases (>90%), while a delay of up to forty-eight hours in treatment still greatly reduces mortality following exposure (65%). Moreover, passive immunotherapy protects against enteric invasion, associated mucosal injury and subsequent dissemination by gastrointestinal B. anthracis, indicating that it acts to prevent the initial stages of infection. * Expired raxibacumab being cycled off the Strategic National Stockpile; biological activity confirmed by in vitro assay. PMID:26426050

  6. Passive Immunotherapy Protects against Enteric Invasion and Lethal Sepsis in a Murine Model of Gastrointestinal Anthrax.

    PubMed

    Huang, Bruce; Xie, Tao; Rotstein, David; Fang, Hui; Frucht, David M

    2015-09-29

    The principal portal for anthrax infection in natural animal outbreaks is the digestive tract. Enteric exposure to anthrax, which is difficult to detect or prevent in a timely manner, could be exploited as an act of terror through contamination of human or animal food. Our group has developed a novel animal model of gastrointestinal (GI) anthrax for evaluation of disease pathogenesis and experimental therapeutics, utilizing vegetative Bacillus anthracis (Sterne strain) administered to A/J mice (a complement-deficient strain) by oral gavage. We hypothesized that a humanized recombinant monoclonal antibody (mAb) * that neutralizes the protective antigen (PA) component of B. anthracis lethal toxin (LT) and edema toxin (ET) could be an effective treatment. Although the efficacy of this anti-anthrax PA mAb has been shown in animal models of inhalational anthrax, its activity in GI infection had not yet been ascertained. We hereby demonstrate that passive immunotherapy with anti-anthrax PA mAb, administered at the same time as gastrointestinal exposure to B. anthracis, prevents lethal sepsis in nearly all cases (>90%), while a delay of up to forty-eight hours in treatment still greatly reduces mortality following exposure (65%). Moreover, passive immunotherapy protects against enteric invasion, associated mucosal injury and subsequent dissemination by gastrointestinal B. anthracis, indicating that it acts to prevent the initial stages of infection. * Expired raxibacumab being cycled off the Strategic National Stockpile; biological activity confirmed by in vitro assay.

  7. Find and treat or find and lose? Tuberculosis treatment outcomes among screened newly arrived asylum seekers in Germany 2002 to 2014.

    PubMed

    Kuehne, Anna; Hauer, Barbara; Brodhun, Bonita; Haas, Walter; Fiebig, Lena

    2018-03-01

    BackgroundGermany has a low tuberculosis (TB) incidence. A relevant and increasing proportion of TB cases is diagnosed among asylum seekers upon screening. Aim: We aimed to assess whether cases identified by screening asylum seekers had equally successful and completely reported treatment outcomes as cases diagnosed by passive case finding and contact tracing in the general population. Methods: We analysed characteristics and treatment outcomes of pulmonary TB cases notified in Germany between 2002 and 2014, stratified by mode of case finding. We performed three multivariable analyses with different dependent variables: Model A: successful vs all other outcomes, Model B: successful vs documented non-successful clinical outcome and Model C: known outcome vs lost to follow-up. Results: TB treatment success was highest among cases identified by contact tracing (87%; 3,139/3,591), followed by passive case finding (74%; 28,804/39,019) and by screening asylum seekers (60%; 884/1,474). Cases identified by screening asylum seekers had 2.4 times higher odds of not having a successful treatment outcome as opposed to all other outcomes (A), 1.4 times higher odds of not having a successful treatment outcome as opposed to known non-successful outcomes (B) and 2.3 times higher odds of loss to follow-up (C) than cases identified by passive case finding. Conclusion: Screened asylum seekers had poorer treatment outcomes and were more often lost to follow-up. Linking patients to treatment facilities and investigating potential barriers to treatment completion are needed to secure screening benefits for asylum seekers and communities.

  8. Vector-borne disease surveillance in livestock populations: A critical review of literature recommendations and implemented surveillance (BTV-8) in five European countries.

    PubMed

    Dórea, Fernanda C; Elbers, Armin R W; Hendrikx, Pascal; Enoe, Claes; Kirkeby, Carsten; Hoinville, Linda; Lindberg, Ann

    2016-03-01

    Preparedness against vector-borne threats depends on the existence of a long-term, sustainable surveillance of vector-borne disease and their relevant vectors. This work reviewed the availability of such surveillance systems in five European countries (Denmark, France, The Netherlands, Sweden and United Kingdom, part of the CoVetLab network). A qualitative assessment was then performed focusing on surveillance directed particularly to BTV-8. Information regarding surveillance activities were reviewed for the years 2008 and 2012. The results were then complemented with a critical scoping review of the literature aimed at identifying disease surveillance strategies and methods that are currently suggested as best suited to target vector-borne diseases in order to guide future development of surveillance in the countries in question. Passive surveillance was found to be efficient for early detection of diseases during the early phase of introduction into a free country. However, its value diminished once the disease has been established in a territory. Detection of emerging diseases was found to be very context and area specific, and thus active surveillance designs need to take the available epidemiological, ecological and entomological information into account. This was demonstrated by the effectiveness of the bulk milk surveillance in detecting the first case in Sweden, highlighting the need for output based standards to allow the most effective, context dependent, surveillance strategies to be used. Preparedness was of fundamental importance in determining the timeliness of detection and control in each country and that this in turn was heavily influenced by knowledge of emerging diseases in neighboring countries. Therefore it is crucial to share information on outbreaks between researchers and decision-makers and across borders continuously in order to react timely in case of an outbreak. Furthermore, timely reaction to an outbreak was heavily influenced by availability of control measures (vaccines), which is also strengthened if knowledge is shared quickly between countries. The assessment of the bluetongue surveillance in the affected countries showed that the degree of voluntary engagement varied, and that it is important to engage the public by general awareness and dissemination of results. The degree of engagement will also aid in establishing a passive surveillance system. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. The occurrence of reactions and impairments in leprosy: experience in the leprosy control program of three provinces in northeastern Thailand, 1987-1995 [correction of 1978-1995]. I. Overview of the study.

    PubMed

    Schreuder, P A

    1998-06-01

    This paper is the first in a series of three reports on the occurrence of reactions and impairments in leprosy in Thailand. This first paper gives a general overview about the methodology of the study, some epidemiological observations, delay in detection, multidrug therapy (MDT) completion rates and relapses. The other two papers report on: II. Reactions and III. Neural and Other Impairments. This study was carried out from 1987 until 1995 in three neighboring provinces in northeastern Thailand. A population-based, prospective cohort study. All 640 newly diagnosed leprosy patients in the three provinces, registered between October 1987 and September 1990, were included [420 paucibacillary (PB) and 220 multibacillary (MB)]. This group was followed up (actively and passively) until the end of 1995. Patients were found by active and passive case finding. All new, untreated leprosy patients from the area were enrolled and started on the World Health Organization (WHO) MDT (WHO/MDT) regimen. A vertical control service was run by specialized leprosy workers. During treatment the patients received their monthly doses at home. During surveillance the patients were followed up once a year by a special team. Patients were questioned about delay in detection. Treatment completion rates were calculated. The occurrence of reactions and neural and other impairments at the beginning of, during and after treatment was ascertained. After treatment, the occurrence of late reactions and relapses was recorded. A higher frequency of leprosy was found among the male patients, especially in the MB group. However, in the PB group a higher female/male ratio was found in the age group 55 years and older. There was an increase in the detection rate from the youngest age group to the age group 55 years and older, which showed the highest detection rate. Treatment completion rates were high, 95% in both in the PB and MB treatment groups. About 50% of the new cases reported a delay between onset and registration of 1 year or more. By 1995, 93% of the original patient group was still available for follow up. By the end of 1995, 8 PB and 2 MB relapses were recorded.

  10. Use of radio-tagging to map spatial organization and social interactions in insects.

    PubMed

    Moreau, Mathieu; Arrufat, Patrick; Latil, Gérard; Jeanson, Raphaël

    2011-01-01

    Understanding of the organization of animal societies often requires knowledge of the identity of group members and their spatial location. We propose an original experimental design to track automatically the position of individuals using radio frequency identification technology (RFID). Ants equipped with passive transponders were detected by a reader mounted on a mobile arm moving across the nest surface. We developed an algorithm to accurately extract the positions of individuals moving in two dimensions. Our method was validated on synthetic test cases and then used for characterization of the spatial distribution of ants within nests. This approach provides an amenable system for monitoring large populations of individuals over long periods of time.

  11. Moonquakes and lunar tectonism results from the Apollo passive seismic experiment.

    NASA Technical Reports Server (NTRS)

    Latham, G.; Ewing, M.; Dorman, J.; Lammlein, D.; Press, F.; Toksoz, N.; Sutton, G.; Duennebier, F.; Nakamura, Y.

    1972-01-01

    The natural seismicity of the moon appears to be very low relative to that of the earth. However, moonquakes do occur. They are detected by the stations of the Apollo seismic network at an average rate of 1800/yr at Station 14 and at lower rates at Stations 12 and 15. All of the moonquakes are small, and in the few cases for which the foci have been located, they occur at great depth (about 800 km). The frequency of occurrence of moonquakes is strongly correlated with lunar tides. The dynamic processes that generate quakes are clearly much less vigorous within the moon than they are within the earth.

  12. Small Business Innovation Research (SBIR) Program. FY 1991 Program Solicitation 91.2

    DTIC Science & Technology

    1991-07-01

    Based Robotic Control Systems Technology A91-034 Passive Sensor Self- Interference Cancellation A91-035 High Performance Propelling Charges A91-036...laboratory tests. A91-034 TITLE: Passive Sensor Self- Interference Cancellation CATEGORY: Exploratory Development OBJECTIVE: Develop practical and effective...acoustic sensor to detect, classify, identify, and locate targets is ARMY 19 degraded by own-platform noise and local interference . Elementary

  13. Improvements to Passive Acoustic Tracking Methods for Marine Mammal Monitoring

    DTIC Science & Technology

    2016-05-02

    separate and associate calls from individual animals . Marine mammal; Passive acoustic monitoring; Localization; Tracking; Multiple source; Sparse array...position and hydrophone timing offset in addition to animal position Almost all marine mammal tracking methods treat animal position as the only unknown...Workshop on Detection, Classification and Localization (DCL) of Marine Mammals). The animals were expected to be relatively close to the surface

  14. Pointing control system design and performance evaluation of TPF coronagraph

    NASA Astrophysics Data System (ADS)

    Liu, Kuo-Chia; Blaurock, Carl; Mosier, Gary E.

    2004-09-01

    The Terrestrial Planet Finder (TPF) project aims to detect and characterize extra-solar Earth-like planets. The coronagraph telescope is one of the two mission concepts being studied. To reject the star flux and detect the planet flux in the visible light range, the coronagraph telescope must achieve a rejection ratio on the order of a billion to one. Dynamic jitter, introduced by environmental and on-board mechanical disturbances, degrades the optical performance, as characterized primarily by contrast ratio. The feasibility of using passive vibration isolation combined with active attitude and line-of-sight (LOS) control systems to stabilize the spacecraft and the optical components to the requisite level is being studied. The telescope is also required to slew between targets or rotate around the LOS. The slew mode control law must be designed to balance the need for efficient large-angle maneuvers while simultaneously avoiding the excitation of flexible modes in order to minimize settling time. This paper provides an overview of the current control design concept and sensor/actuator topology for TPF Coronagraph and illustrates the fine pointing performance of the telescope. This performance is primarily a function of the rejection of high-frequency dynamic disturbances, in this case due to reaction wheel disturbance forces/torques transmitted through the passive isolation stage. Trade studies between isolator force rejection and disturbance level reduction via wheel redesign are also presented to illustrate the requirements imposed on current technologies. Finally, the paper summarizes preliminary results on the slew/settle performance of the telescope.

  15. Time-to-impact estimation in passive missile warning systems

    NASA Astrophysics Data System (ADS)

    Şahıngıl, Mehmet Cihan

    2017-05-01

    A missile warning system can detect the incoming missile threat(s) and automatically cue the other Electronic Attack (EA) systems in the suit, such as Directed Infrared Counter Measure (DIRCM) system and/or Counter Measure Dispensing System (CMDS). Most missile warning systems are currently based on passive sensor technology operating in either Solar Blind Ultraviolet (SBUV) or Midwave Infrared (MWIR) bands on which there is an intensive emission from the exhaust plume of the threatening missile. Although passive missile warning systems have some clear advantages over pulse-Doppler radar (PDR) based active missile warning systems, they show poorer performance in terms of time-to-impact (TTI) estimation which is critical for optimizing the countermeasures and also "passive kill assessment". In this paper, we consider this problem, namely, TTI estimation from passive measurements and present a TTI estimation scheme which can be used in passive missile warning systems. Our problem formulation is based on Extended Kalman Filter (EKF). The algorithm uses the area parameter of the threat plume which is derived from the used image frame.

  16. Independent and joint exposure to passive smoking and cooking oil fumes on oral cancer in Chinese women: a hospital-based case-control study.

    PubMed

    He, Baochang; Chen, Fa; Yan, Lingjun; Huang, Jiangfeng; Liu, Fangping; Qiu, Yu; Lin, Lisong; Zhang, Zuofeng; Cai, Lin

    2016-10-01

    Passive smoking and COF exposure are independent risk factors for oral cancer in Chinese women, with the multiplicative interactions from combined exposures. Avoiding exposure to environmental tobacco smoke and COF may contribute to the prevention of oral cancer in Chinese women. To evaluate the independent and joint effects of passive smoking and cooking oil fumes (COF) on oral cancer in Chinese women. A case-control study was performed including 238 female patients with pathologically confirmed oral cancer and 470 controls as age-matched controls. Face-to-face interviews were conducted based on a structured questionnaire. The effects of passive smoking and COF exposure were analyzed using non-conditional logistic regression models. Passive smoking significantly increased the risk of oral cancer in Chinese women: adjusted ORs were 2.12 (95% CI = 1.11-4.07) for those only exposed before age 18, 1.52 (95% CI = 1.01-2.31) for those only exposed after age 18, and 2.38 (95% CI = 1.47-3.85) for those both exposed before and after age 18. In addition, COF exposure was significantly associated with a risk of oral cancer (adjusted ORs were 1.69 (95% CI = 1.03-2.78) for light exposure and 2.06 (95% CI = 1.21-3.50) for heavy exposure). Furthermore, there was a significantly multiplicative interaction between passive smoking and COF for oral cancer.

  17. Passive Euro-American terahertz camera (PEAT-CAM): passive indoor THz imaging at video rates for security applications

    NASA Astrophysics Data System (ADS)

    Luukanen, Arttu; Grönberg, Leif; Helistö, Panu; Penttilä, Jari S.; Seppä, Heikki; Sipola, Hannu; Dietlein, Charles R.; Grossman, Erich N.

    2007-04-01

    The objective of this program is to demonstrate a system capable of passive indoors detection and identification of concealed threat items hidden underneath the clothing of non-cooperative subjects from a stand-off distance of several meters. To meet this difficult task, we are constructing an imaging system utilising superconducting ultrawideband antenna-coupled microbolometers, coupled to innovative room temperature read-out electronics, and operated within a cryogen-free pulse tube refrigerator. Previously, we have demonstrated that these devices are capable of a Noise Equivalent Temperature Difference (NETD) of 125 mK over a pre-detection bandwidth from 0.2-1 THz using a post-detection integration time of 30 ms. Further improvements on our devices are reducing this number to a few tens of mK. Such an exquisite sensitivity is necessary in order to achieve the undoubtedly stringent requirements for low false positive alarm rate combined with high probability of detection dictated by the application. Our technological approach allows for excellent per frame NETD (objective 0.5 K or below at 30 Hz frame rate), and is also amenable to multispectral (colour) imagery that enhances the discrimination of innocuous objects against real threats. In the paper we present results obtained with an 8-pixel subarray from our linear array of 128 pixels constructed using a modular approach. Two-dimensional imaging will be achieved by the use of conical scanning.

  18. Passivity of Directed and Undirected Complex Dynamical Networks With Adaptive Coupling Weights.

    PubMed

    Wang, Jin-Liang; Wu, Huai-Ning; Huang, Tingwen; Ren, Shun-Yan; Wu, Jigang

    2017-08-01

    A complex dynamical network consisting of N identical neural networks with reaction-diffusion terms is considered in this paper. First, several passivity definitions for the systems with different dimensions of input and output are given. By utilizing some inequality techniques, several criteria are presented, ensuring the passivity of the complex dynamical network under the designed adaptive law. Then, we discuss the relationship between the synchronization and output strict passivity of the proposed network model. Furthermore, these results are extended to the case when the topological structure of the network is undirected. Finally, two examples with numerical simulations are provided to illustrate the correctness and effectiveness of the proposed results.

  19. The use of far infra-red radiation for the detection of concealed metal objects

    DOT National Transportation Integrated Search

    1971-11-01

    The use of infrared radiation for the detection of concealed metal objects has been investigated both theoretically and experimentally. The investigation was divided into two phases, one which considered passive techniques, and another which involved...

  20. The use of far infra-red radiation for the detection of concealed metal objects.

    DOT National Transportation Integrated Search

    1971-11-01

    Abstract The use of infrared radiation for the detection : of concealed metal objects has been investigated both : theoretically and experimentally. The investigation was : divided into two phases, one which considered passive : techniques, and anoth...

  1. Non-human primate skull effects on the cavitation detection threshold of FUS-induced blood-brain barrier opening

    NASA Astrophysics Data System (ADS)

    Wu, Shih-Ying; Tung, Yao-Sheng; Marquet, Fabrice; Chen, Cherry C.; Konofagou, Elisa E.

    2012-11-01

    Microbubble (MB)-assisted focused ultrasound is a promising technique for delivering drugs to the brain by noninvasively and transiently opening the blood-brain barrier (BBB), and monitoring BBB opening using passive cavitation detection (PCD) is critical in detecting its occurrence, extent as well as assessing its mechanism. One of the main obstacles in achieving those objectives in large animals is the transcranial attenuation. To study the effects, the cavitation response through the in-vitro non-human primate (NHP) skull was investigated. In-house manufactured lipid-shelled MB (medium diameter: 4-5 um) were injected into a 4-mm channel of a phantom below a degassed monkey skull. A hydrophone confocally aligned with the FUS transducer served as PCD during sonication (frequency: 0.50 MHz, peak rarefactional pressures: 0.05-0.60 MPa, pulse length: 100 cycles, PRF: 10 Hz, duration: 2 s) for four cases: water without skull, water with skull, MB without skull and MB with skull. A 5.1-MHz linear-array transducer was also used to monitor the MB disruption. The frequency spectra, spectrograms, stable cavitation dose (SCD) and inertial cavitation dose (ICD) were quantified. Results showed that the onset of stable cavitation and inertial cavitation in the experiments occurred at 50 kPa, and was detectable throught the NHP skull since the both the detection thresholds for stable cavitation and inertial cavitation remained unchanged compared to the non-skull case, and the SCD and ICD acquired transcranially may not adequately represent the true extent of stable and inertial cavitation due to the skull attenuation.

  2. Snapshot imaging Fraunhofer line discriminator for detection of plant fluorescence

    NASA Astrophysics Data System (ADS)

    Gupta Roy, S.; Kudenov, M. W.

    2015-05-01

    Non-invasive quantification of plant health is traditionally accomplished using reflectance based metrics, such as the normalized difference vegetative index (NDVI). However, measuring plant fluorescence (both active and passive) to determine photochemistry of plants has gained importance. Due to better cost efficiency, lower power requirements, and simpler scanning synchronization, detecting passive fluorescence is preferred over active fluorescence. In this paper, we propose a high speed imaging approach for measuring passive plant fluorescence, within the hydrogen alpha Fraunhofer line at ~656 nm, using a Snapshot Imaging Fraunhofer Line Discriminator (SIFOLD). For the first time, the advantage of snapshot imaging for high throughput Fraunhofer Line Discrimination (FLD) is cultivated by our system, which is based on a multiple-image Fourier transform spectrometer and a spatial heterodyne interferometer (SHI). The SHI is a Sagnac interferometer, which is dispersion compensated using blazed diffraction gratings. We present data and techniques for calibrating the SIFOLD to any particular wavelength. This technique can be applied to quantify plant fluorescence at low cost and reduced complexity of data collection.

  3. Passive monitoring and localization of marine mammals in open ocean environments using widely spaced bottom mounted hydrophones

    NASA Astrophysics Data System (ADS)

    Jarvis, Susan; Moretti, David; Morrissey, Ronald; Dimarzio, Nancy

    2003-10-01

    The Marine Mammal Monitoring on Navy Ranges (M3R) project has developed a toolset for passive detection and localization of marine mammals using the existing infrastructure of Navy's undersea ranges. The Office of Naval Research funded the M3R project as part of the Navy's effort to determine the effects of acoustic and other emissions on marine mammals and threatened/endangered species. A necessary first step in this effort is the creation of a baseline of behavior, which requires long-term monitoring of marine mammals. Such monitoring, in turn, requires the ability to detect and localize the animals. This paper will present the passive acoustic monitoring and localization tools developed under M3R. It will also present results of the deployment of the M3R tools at the Atlantic Undersea Test and Evaluation Center (AUTEC), Andros Island, Bahamas from June through November 2003. Finally, it will discuss current work to improve automated species classification.

  4. A Simulation Study of Acoustic-Assisted Tracking of Whales for Mark-Recapture Surveys

    PubMed Central

    Peel, David; Miller, Brian S.; Kelly, Natalie; Dawson, Steve; Slooten, Elisabeth; Double, Michael C.

    2014-01-01

    Collecting enough data to obtain reasonable abundance estimates of whales is often difficult, particularly when studying rare species. Passive acoustics can be used to detect whale sounds and are increasingly used to estimate whale abundance. Much of the existing effort centres on the use of acoustics to estimate abundance directly, e.g. analysing detections in a distance sampling framework. Here, we focus on acoustics as a tool incorporated within mark-recapture surveys. In this context, acoustic tools are used to detect and track whales, which are then photographed or biopsied to provide data for mark-recapture analyses. The purpose of incorporating acoustics is to increase the encounter rate beyond using visual searching only. While this general approach is not new, its utility is rarely quantified. This paper predicts the “acoustically-assisted” encounter rate using a discrete-time individual-based simulation of whales and survey vessel. We validate the simulation framework using existing data from studies of sperm whales. We then use the framework to predict potential encounter rates in a study of Antarctic blue whales. We also investigate the effects of a number of the key parameters on encounter rate. Mean encounter rates from the simulation of sperm whales matched well with empirical data. Variance of encounter rate, however, was underestimated. The simulation of Antarctic blue whales found that passive acoustics should provide a 1.7–3.0 fold increase in encounter rate over visual-only methods. Encounter rate was most sensitive to acoustic detection range, followed by vocalisation rate. During survey planning and design, some indication of the relationship between expected sample size and effort is paramount; this simulation framework can be used to predict encounter rates and establish this relationship. For a case in point, the simulation framework indicates unequivocally that real-time acoustic tracking should be considered for quantifying the abundance of Antarctic blue whales via mark-recapture methods. PMID:24827919

  5. A simulation study of acoustic-assisted tracking of whales for mark-recapture surveys.

    PubMed

    Peel, David; Miller, Brian S; Kelly, Natalie; Dawson, Steve; Slooten, Elisabeth; Double, Michael C

    2014-01-01

    Collecting enough data to obtain reasonable abundance estimates of whales is often difficult, particularly when studying rare species. Passive acoustics can be used to detect whale sounds and are increasingly used to estimate whale abundance. Much of the existing effort centres on the use of acoustics to estimate abundance directly, e.g. analysing detections in a distance sampling framework. Here, we focus on acoustics as a tool incorporated within mark-recapture surveys. In this context, acoustic tools are used to detect and track whales, which are then photographed or biopsied to provide data for mark-recapture analyses. The purpose of incorporating acoustics is to increase the encounter rate beyond using visual searching only. While this general approach is not new, its utility is rarely quantified. This paper predicts the "acoustically-assisted" encounter rate using a discrete-time individual-based simulation of whales and survey vessel. We validate the simulation framework using existing data from studies of sperm whales. We then use the framework to predict potential encounter rates in a study of Antarctic blue whales. We also investigate the effects of a number of the key parameters on encounter rate. Mean encounter rates from the simulation of sperm whales matched well with empirical data. Variance of encounter rate, however, was underestimated. The simulation of Antarctic blue whales found that passive acoustics should provide a 1.7-3.0 fold increase in encounter rate over visual-only methods. Encounter rate was most sensitive to acoustic detection range, followed by vocalisation rate. During survey planning and design, some indication of the relationship between expected sample size and effort is paramount; this simulation framework can be used to predict encounter rates and establish this relationship. For a case in point, the simulation framework indicates unequivocally that real-time acoustic tracking should be considered for quantifying the abundance of Antarctic blue whales via mark-recapture methods.

  6. Magneto-electronic properties of graphene nanoribbons with various edge structures passivated by phosphorus and hydrogen atoms.

    PubMed

    Yu, Z L; Wang, D; Zhu, Z; Zhang, Z H

    2015-10-07

    The electronic and magnetic structures of graphene nanoribbons (GNRs) with various edge structures passivated by P atoms are investigated systematically, and compared with H passivation as well. GNRs with the entire reconstructed Klein edge or armchair edge are found to be nonmagnetic regardless of P or H passivation. However, if the edge of GNRs is a mixture of zigzag edge and reconstructed Klein edge, they are nonmagnetic for H passivation but significantly magnetic for P passivation, which could be attributed to the "charge transfer doping" effect. And the corresponding magnetic device shows a noticeable negative differential resistance phenomenon and an excellent spin filtering effect under AP configuration, which originate from the special energy band structure. The GNRs with zigzag edge, reconstructed Klein edge, or mixed edge shapes are all metals in the nonmagnetic state regardless of the H or P atoms involved. The relationship between the energy gap and the width in armchair-edged GNRs by P passivation with a dimer structure also satisfies the 3p periodicity, but different in detail from the case of H passivation. The calculated edge formation energy indicates that P-passivated GNRs are energetically more favorable, suggesting that they can stably exist in the experiment.

  7. Passive-dynamic ankle-foot orthosis replicates soleus but not gastrocnemius muscle function during stance in gait: Insights for orthosis prescription.

    PubMed

    Arch, Elisa S; Stanhope, Steven J; Higginson, Jill S

    2016-10-01

    Passive-dynamic ankle-foot orthosis characteristics, including bending stiffness, should be customized for individuals. However, while conventions for customizing passive-dynamic ankle-foot orthosis characteristics are often described and implemented in clinical practice, there is little evidence to explain their biomechanical rationale. To develop and combine a model of a customized passive-dynamic ankle-foot orthosis with a healthy musculoskeletal model and use simulation tools to explore the influence of passive-dynamic ankle-foot orthosis bending stiffness on plantar flexor function during gait. Dual case study. The customized passive-dynamic ankle-foot orthosis characteristics were integrated into a healthy musculoskeletal model available in OpenSim. Quasi-static forward dynamic simulations tracked experimental gait data under several passive-dynamic ankle-foot orthosis conditions. Predicted muscle activations were calculated through a computed muscle control optimization scheme. Simulations predicted that the passive-dynamic ankle-foot orthoses substituted for soleus but not gastrocnemius function. Induced acceleration analyses revealed the passive-dynamic ankle-foot orthosis acts like a uniarticular plantar flexor by inducing knee extension accelerations, which are counterproductive to natural knee kinematics in early midstance. These passive-dynamic ankle-foot orthoses can provide plantar flexion moments during mid and late stance to supplement insufficient plantar flexor strength. However, the passive-dynamic ankle-foot orthoses negatively influenced knee kinematics in early midstance. Identifying the role of passive-dynamic ankle-foot orthosis stiffness during gait provides biomechanical rationale for how to customize passive-dynamic ankle-foot orthoses for patients. Furthermore, these findings can be used in the future as the basis for developing objective prescription models to help drive the customization of passive-dynamic ankle-foot orthosis characteristics. © The International Society for Prosthetics and Orthotics 2015.

  8. Impact detection and analysis/health monitoring system for composites

    NASA Astrophysics Data System (ADS)

    Child, James E.; Kumar, Amrita; Beard, Shawn; Qing, Peter; Paslay, Don G.

    2006-05-01

    This manuscript includes information from test evaluations and development of a smart event detection system for use in monitoring composite rocket motor cases for damaging impacts. The primary purpose of the system as a sentry for case impact event logging is accomplished through; implementation of a passive network of miniaturized piezoelectric sensors, logger with pre-determined force threshold levels, and analysis software. Empirical approaches to structural characterizations and network calibrations along with implementation techniques were successfully evaluated, testing was performed on both unloaded (less propellants) as well as loaded rocket motors with the cylindrical areas being of primary focus. The logged test impact data with known physical network parameters provided for impact location as well as force determination, typically within 3 inches of actual impact location using a 4 foot network grid and force accuracy within 25%of an actual impact force. The simplistic empirical characterization approach along with the robust / flexible sensor grids and battery operated portable logger show promise of a system that can increase confidence in composite integrity for both new assets progressing through manufacturing processes as well as existing assets that may be in storage or transportation.

  9. Case study: videogame distraction reduces behavioral distress in a preschool-aged child undergoing repeated burn dressing changes: a single-subject design.

    PubMed

    Sil, Soumitri; Dahlquist, Lynnda M; Burns, Andrew J

    2013-04-01

    This single-subject design study evaluated the feasibility and efficacy of passive and interactive videogame distraction on behavioral distress for a preschool-aged child receiving repeated burn dressing changes. A 4-year-old girl underwent 3 baseline and 10 videogame distraction sessions (5 passive and 5 interactive) using a restricted alternating treatments design. Observed behavioral distress was coded, and parents and nurses rated the child's distress and cooperative behavior. Relative to baseline, behavioral distress decreased and cooperative behavior increased immediately after the onset of videogame distraction. Single Case Randomization Tests revealed significantly lower behavioral distress and greater cooperation during interactive videogame distraction relative to passive videogame distraction. Interactive videogame distraction appears to be a feasible and effective pain management strategy for a preschool-aged child undergoing repeated painful medical procedures.

  10. Pervasive refusal syndrome. Three German cases provide further illustration.

    PubMed

    Jans, Thomas; Ball, Juliane; Preiss, Maike; Haberhausen, Michael; Warnke, Andreas; Renner, Tobias J

    2011-09-01

    Pervasive refusal syndrome (PRS) has been proposed as a new diagnostic entity among child and adolescent psychiatric disorders. It is characterized by a cluster of life-threatening symptoms including refusal of hood intake, decreased or complete lack of mobilization, and lack of communication as well as retreat from normal life activities. Active refusal to accept help as well as neglect of personal care have been core features of PRS in the limited number of cases reported in the last decade. There have, however; been cases with predominantly passive resistance, indicating the possibility that there may be a continuum from active refusal to passive resistance within PRS. Postulating this continuum allows for the integration of "depressive devitalization" -- a refusal syndrome mainly characterized by passive resistance -- into the concept of PRS. Here, three case vignettes of adolescent patients with PRS are presented. The patients' symptomatology can be allocated on this continuum of PRS. PRS and dissociative disorders are compared in greater detail and contrasted within this discussion of differential diagnoses at the poles of such a continuum. PRS is a useful diagnosis for cases involving symptoms of predominating refusal and retreat which cannot satisfactorily be classified by existing diagnostic categories, and which can mostly clearly be separated from dissociative disorder.

  11. Physical criteria for the interface passivation layer in hydrogenated amorphous/crystalline silicon heterojunction solar cell

    NASA Astrophysics Data System (ADS)

    Zhao, Lei; Wang, Guanghong; Diao, Hongwei; Wang, Wenjing

    2018-01-01

    AFORS-HET (automat for simulation of heterostructures) simulation was utilized to explore the physical criteria for the passivation layer in hydrogenated amorphous/crystalline silicon heterojunction (SHJ) solar cells, by systematically investigating the solar cell current density-voltage (J-V) performance as a function of the interface defect density (D it) at the passivation layer/c-Si hetero-interface, the thickness (t) of the passivation layer, the bandgap (E g) of the passivation layer, and the density of dangling bond states (D db)/band tail states (D bt) in the band gap of the passivation layer. The corresponding impact regulations were presented clearly. Except for D it, the impacts of D db, D bt and E g are strongly dependent on the passivation layer thickness t. While t is smaller than 4-5 nm, the solar cell performance is less sensitive to the variation of D db, D bt and E g. Low D it at the a-Si:H/c-Si interface and small thickness t are the critical criteria for the passivation layer in such a case. However, if t has to be relatively larger, the microstructure, i.e. the material quality, including D db, D bt and E g, of the passivation layer should be controlled carefully. The mechanisms involved were analyzed and some applicable methods to prepare the passivation layer were proposed.

  12. A case-control study of the relationship between a passive second stage of labor and obstetric anal sphincter injuries.

    PubMed

    Gossett, Dana R; Deibel, Philip; Lewicky-Gaupp, Christina

    2016-02-01

    To estimate the relationship between a passive second stage of labor and obstetric anal sphincter injuries (OASIS). A retrospective, case-control study was undertaken of women who delivered at a tertiary-care center in Chicago, IL, USA, between November 2005 and December 2012. Cases had sustained OASIS and were matched on the basis of parity with controls who had no OASIS. Data were obtained from an electronic repository and chart review. Participants with a passive second stage of labor lasting 60 minutes or more were deemed to have "labored down." A logistic regression model to predict OASIS was created. Overall, 1629 cases were compared with 1312 controls. OASIS were recorded among 1452 (57.8%) of 2510 women who did not labor down compared with 169 (40.0%) of 423 women who labored down (P<0.001). However, in binary logistic regression, the addition of laboring down to the model only increased the predictive accuracy from 80.1% to 80.7%. When known risk factors for OASIS are accounted for, the effect of laboring down on perineal outcome is negligible. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  13. TB control programmes: the challenges for Africa.

    PubMed

    Harries, T

    1996-11-01

    Governmental neglect of tuberculosis (TB), inadequately managed and inaccurately designed TB control programs, population growth, and the HIV epidemic account for the resurgence of TB in sub-Saharan Africa. The World Health Organization and the International Union against TB and Lung Disease have developed a TB control strategy that aims to reduce mortality, morbidity, and transmission of TB. It aims for an 85% cure rate among detected new cases of smear-positive TB and a 70% rate of detecting existing smear-positive TB cases. The strategy involves the provision of short-course chemotherapy (SCC) to all identified smear-positive TB cases through directly observed treatment (DOTS). SCC treatment regimens for smear-positive pulmonary TB recommended for sub-Saharan African countries are: initial phase = daily administration over 2 months of streptomycin, rifampicin, isoniazid, and pyrazinamide; continuation phase = 3 doses over 4 months of isoniazid and rifampicin or daily administration of thiacetazone and isoniazid or of ethambutol and isoniazid. A TB control policy must be implemented to bring about effective TB control. The essential elements of this policy include political commitment, case detection through passive case-finding, SCC, a regular supply of essential drugs, and a monitoring and evaluation system. Political commitment involves establishing a National TB Control Program to be integrated into the existing health structure. Increased awareness of TB in the community and among health workers and a reference laboratory are needed to make case finding successful. A distribution and logistics system is needed to ensure uninterrupted intake of drugs throughout treatment. These regimens have been very successful and cost-effective but pose several disadvantages (e.g., heavy workload of recommended 3 sputum smear tests). A simplified approach involves 1 initial sputum smear for 6 months; 6-months, intermittent rifampicin-based therapy, 100% DOTS throughout entire treatment course, and ascertainment of treatment completion rates and mortality rates in all patients.

  14. The surface geometry of inherited joint and fracture trace patterns resulting from active and passive deformation

    NASA Technical Reports Server (NTRS)

    Podwysocki, M. H.; Gold, D. P.

    1974-01-01

    Hypothetical models are considered for detecting subsurface structure from the fracture or joint pattern, which may be influenced by the structure and propagated to the surface. Various patterns of an initially orthogonal fracture grid are modeled according to active and passive deformation mechanisms. In the active periclinal structure with a vertical axis, fracture frequency increased both over the dome and basin, and remained constant with decreasing depth to the structure. For passive periclinal features such as a reef or sand body, fracture frequency is determined by the arc of curvature and showed a reduction over the reefmound and increased over the basin.

  15. Passive Fully Polarimetric W-Band Millimeter-Wave Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernacki, Bruce E.; Kelly, James F.; Sheen, David M.

    2012-04-01

    We present the theory, design, and experimental results obtained from a scanning passive W-band fully polarimetric imager. Passive millimeter-wave imaging offers persistent day/nighttime imaging and the ability to penetrate dust, clouds and other obscurants, including clothing and dry soil. The single-pixel scanning imager includes both far-field and near-field fore-optics for investigation of polarization phenomena. Using both fore-optics, a variety of scenes including natural and man-made objects was imaged and these results are presented showing the utility of polarimetric imaging for anomaly detection. Analysis includes conventional Stokes-parameter based approaches as well as multivariate image analysis methods.

  16. Age-related Decline in Case-Marker Processing and its Relation to Working Memory Capacity.

    PubMed

    Sung, Jee Eun

    2017-09-01

    Purposes of the current study were to investigate whether age-related decline emerged in a case-marker assignment task (CMAT) and to explore the relationship between working-memory (WM) capacity and case-marker processing. A total of 121 individuals participated in the study with 62 younger adults and 59 elderly adults. All were administered a CMAT that consisted of active and passive constructions with canonical and noncanonical word-order conditions. A composite measure of WM tasks served as an index of participants' WM capacity. The older group performed worse than the younger group, and the noncanonical word order elicited worse performance than the canonical condition. The older group demonstrated greater difficulty in case-marker processing under the canonical condition and passive construction. Regression results revealed that age, education, and sentence type were the best predictors to account for performance on the CMAT. The canonicity of word order and passive construction were critical factors related to decline in abilities in a case-marker assignment. The combination of age, education, and sentence type factors accounted for overall performance on case-marker processing. Results indicated the crucial necessity to find a cognitively and linguistically demanding condition that elicits aging effects most efficiently, considering language-specific syntactic features. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Sputter-Deposited Oxides for Interface Passivation of CdTe Photovoltaics

    DOE PAGES

    Kephart, Jason M.; Kindvall, Anna; Williams, Desiree; ...

    2018-01-18

    Commercial CdTe PV modules have polycrystalline thin films deposited on glass, and devices made in this format have exceeded 22% efficiency. Devices made by the authors with a magnesium zinc oxide window layer and tellurium back contact have achieved efficiency over 18%, but these cells still suffer from an open-circuit voltage far below ideal values. Oxide passivation layers made by sputter deposition have the potential to increase voltage by reducing interface recombination. CdTe devices with these passivation layers were studied with photoluminescence (PL) emission spectroscopy and time-resolved photoluminescence (TRPL) to detect an increase in minority carrier lifetime. Because these oxidemore » materials exhibit barriers to carrier collection, micropatterning was used to expose small point contacts while still allowing interface passivation. TRPL decay lifetimes have been greatly enhanced for thin polycrystalline absorber films with interface passivation. Device performance was measured and current collection was mapped spatially by light-beam-induced current.« less

  18. The passive river restoration approach as an efficient tool to improve the hydromorphological diversity of rivers - Case study from two river restoration projects in the German lower mountain range

    NASA Astrophysics Data System (ADS)

    Groll, M.

    2017-09-01

    Intensive use of European rivers during the last hundreds of years has led to profound changes in the physicochemical properties, river morphology, and aquatic faunistic communities. Rectifying these changes and improving the ecological state of all surface water bodies is the central aim of the European Water Frame Directive (WFD), and river restoration measures are the main tool to achieve this goal for many rivers. As the cost-effectiveness of all measures is crucial to the WFD implementation, the approach of the passive river restoration has become very popular over the last decades. But while costs of this approach are minimal, not much is known about the long-term effectiveness of passive river restorations. The research presented here provides essential and in-depth data about the effects of two such restoration measures on the riverbed morphology of a large river of the lower mountain region in Germany (type 9.2). More than 3200 data sets were acquired using the TRiSHa method (Typology of Riverbed Structures and Habitats). The results show a high spatial and temporal diversity and dynamic for all analyzed hydromorphologic parameters - ranging from riverbed sediments, organic structures like dead wood or macrophytes, to the distribution of 32 microhabitat types. The structures and their dynamic depend on the character of the study area (free-flowing or impounded), the location of the study sites within the research area (main channel or restored side channel), and on the occurrence of major flood events (the mapping and sampling were conducted annually from 2006 to 2008 with a 50-year flood event occurring in early 2007). These results show the potential of the passive restoration approach for creating morphologically diverse riverbeds, as habitat diversity and the spatial heterogeneity of the riverbed substrates increased significantly (e.g., more than 40% of all habitat types were only detected in the newly restored side channels). But the results also show the limitations of the passive restoration approach, as impounded river sections do not develop as rapidly as their free-flowing counterparts as more than 78% of the restored riverbed in an impounded river stretch remained completely unchanged - even by the 50-year flood event. These differences have to be taken into consideration when formulating the expectations of any passive river restoration.

  19. Passive Bistatic Radar and Waveform Diversity

    DTIC Science & Technology

    2009-11-01

    transmission, but these are significantly beyond the detection ranges of interest. The sidelobe structure of the ambiguity function is flat , as would...kHz (corresponding to a monostatic range resolution c/2B = 3000 m). The transmitters are usually sited on tall towers or masts in high locations. The...peak and the sidelobe structure are well-defined, though the peak Passive Bistatic Radar and Waveform Diversity RTO-EN-SET-119(2009) 3 - 5

  20. Munitions Detection Using Unmanned Underwater Vehicles Equipped with Advanced Sensors

    DTIC Science & Technology

    2012-06-29

    buried target. The RTG is a small passive magnetic sensor using fluxgate magnetometers measuring 3- orthogonal magnetic-field vector components at 3...surveys. Figure 6 shows the RTG magnetic sensor in both an open (showing the fluxgate magnetometers ) and enclosed state (mode for integration onto...7.6 Real-time Tracking Gradiometer (RTG) System The RTG is a small passive magnetic sensor using fluxgate magnetometers measuring 3- orthogonal

  1. Active and Passive Remote Sensing of Ice

    DTIC Science & Technology

    1991-11-15

    To demonstrate the use of polarimetry in passive remote sensing of azimuthally asymmetric features on a terrain surface, an experiment was designed...azimuthal asymmetry on the remotely sensed soil surface. It is also observed from the experiment that the brightness temperatures for all three Stokes...significant implication of this experiment is that the surface asymmetry can be detected with a measurement of U at a single azimuthal angle. -8

  2. Using Passive and Active Acoustics to Examine Relationships of Cetacean and Prey Densities

    DTIC Science & Technology

    2015-09-30

    modulation or production to the marine soundscape with daily, lunar, and seasonal patterns. We aim to document how presence and intensity of certain...sounds relate to spatio-temporal variability of active acoustic backscatter strength. Additionally, several marine mammal species are predators of deep...scattering layer (DSL) species as well as krill. We intend to investigate if passive acoustic marine mammal detections are related to increased

  3. Formation of infectious dengue virus-antibody immune complex in vivo in marmosets (Callithrix jacchus) after passive transfer of anti-dengue virus monoclonal antibodies and infection with dengue virus.

    PubMed

    Moi, Meng Ling; Ami, Yasushi; Shirai, Kenji; Lim, Chang-Kweng; Suzaki, Yuriko; Saito, Yuka; Kitaura, Kazutaka; Saijo, Masayuki; Suzuki, Ryuji; Kurane, Ichiro; Takasaki, Tomohiko

    2015-02-01

    Infection with a dengue virus (DENV) serotype induces cross-reactive, weakly neutralizing antibodies to different dengue serotypes. It has been postulated that cross-reactive antibodies form a virus-antibody immune complex and enhance DENV infection of Fc gamma receptor (FcγR)-bearing cells. We determined whether infectious DENV-antibody immune complex is formed in vivo in marmosets after passive transfer of DENV-specific monoclonal antibody (mAb) and DENV inoculation and whether infectious DENV-antibody immune complex is detectable using FcγR-expressing cells. Marmosets showed that DENV-antibody immune complex was exclusively infectious to FcγR-expressing cells on days 2, 4, and 7 after passive transfer of each of the mAbs (mAb 4G2 and mAb 6B6C) and DENV inoculation. Although DENV-antibody immune complex was detected, contribution of the passively transferred antibody to overall viremia levels was limited in this study. The results indicate that DENV cross-reactive antibodies form DENV-antibody immune complex in vivo, which is infectious to FcγR-bearing cells but not FcγR-negative cells. © The American Society of Tropical Medicine and Hygiene.

  4. Detection of passive movement of the arytenoid cartilage in unilateral vocal-fold paralysis by laryngoscopic observation: useful diagnostic findings.

    PubMed

    Okamoto, Isaku; Tokashiki, Ryoji; Hiramatsu, Hiroyuki; Motohashi, Ray; Suzuki, Mamoru

    2012-02-01

    In a previous study of patients with unilateral vocal-fold paralysis (UVFP), three-dimensional computed tomography (3DCT) revealed passive movement during phonation, with the arytenoid cartilage on the paralyzed side pushed to the unaffected side and deviated upwards. The present work compares the 3DCT findings with those obtained by 2-dimensional endoscopy to visualize the vertical passive movement of the arytenoid cartilage. The study population consisted of 23 patients with UVFP and two with laryngeal deviation but normal movement of the vocal folds. Two endoscopic findings represented cranial deviation during phonation: posterior deviation of the arytenoid hump and lateral deviation of the muscular process. These two findings were classified into four grades, ranging from 0 (normal) to 3 (severe). Cranial displacement detected by 3DCT was also classified into four grades. Significant correlations were found between the 3DCT-determined grade of cranial displacement of the arytenoid cartilage and the grade assigned based on the two endoscopic findings. Moreover, lateral deviation of the muscular process was more significantly correlated with 3DCT grade than with endoscopic grade. Thus, endoscopic findings may be useful in the diagnosis of vocal-fold paralysis, and passive lateral deviation of the muscular process as an indicator of UVFP.

  5. The use of far infra-red radiation for the detection of concealed metal objects.

    DOT National Transportation Integrated Search

    1971-11-01

    The use of infra-red radiation for the detection : of conceal ed metal objects has been investiga ted both : theoretically and experimentally. The investigation was : divided into two phases, one which considered passive : techniques, and another whi...

  6. Meals on Wheels? A Decade of Megafaunal Visual and Acoustic Observations from Offshore Oil & Gas Rigs and Platforms in the North and Irish Seas

    PubMed Central

    Todd, Victoria Louise Georgia; Todd, Ian Boyer

    2016-01-01

    A decade of visual and acoustic detections of marine megafauna around offshore Oil & Gas (O&G) installations in the North and Irish Seas are presented. Marine megafauna activity was monitored visually and acoustically by Joint Nature Conservation Committee (JNCC) qualified and experienced Marine Mammal Observers (MMO) and Passive Acoustic Monitoring (PAM) Operators respectively, with real-time towed PAM in combination with industry standard software, PAMGuard. Monitoring was performed during routine O&G industrial operations for underwater noise mitigation purposes, and to ensure adherence to regulatory guidelines. Incidental sightings by off-effort MMOs and installation crew were also reported. Visual and acoustic monitoring spanned 55 non-consecutive days between 2004 and 2014. A total of 47 marine mammal sightings were recorded by MMOs on dedicated watch, and 10 incidental sightings of marine megafauna were reported over 10 years. Species included: harbour porpoise (Phocoena phocoena), Atlantic white-sided dolphin (Lagenorhynchus acutus), white beaked dolphin (Lagenorhynchus albirostris), common dolphin (Delphinus delphis), minke whale (Balaenoptera acutorostrata), common seal (Phoca vitulina), grey seal (Halichoerus grypus) and, basking shark (Cetorhinus maximus). Passive Acoustic Monitoring was conducted on two occasions in 2014; 160 PAM hours over 12 days recorded a total of 308 individual clicks identified as harbour porpoises. These appear to be the first such acoustic detections obtained from a North Sea drilling rig whilst using a typically configured hydrophone array designed for towing in combination with real-time PAMGuard software. This study provides evidence that marine megafauna are present around mobile and stationary offshore O&G installations during routine operational activities. On this basis, Environmental Impact Assessments (EIAs) for decommissioning O&G platforms should be carried-out on a case-by-case basis, and must include provisions for hitherto overlooked marine megafauna. PMID:27078153

  7. NEW DEVELOPMENTS AND APPLICATIONS OF SUPERHEATED EMULSIONS: WARHEAD VERIFICATION AND SPECIAL NUCLEAR MATERIAL INTERDICTION.

    PubMed

    d'Errico, F; Chierici, A; Gattas-Sethi, M; Philippe, S; Goldston, R; Glaser, A

    2018-04-25

    In recent years, neutron detection with superheated emulsions has received renewed attention thanks to improved detector manufacturing and read-out techniques, and thanks to successful applications in warhead verification and special nuclear material (SNM) interdiction. Detectors are currently manufactured with methods allowing high uniformity of the drop sizes, which in turn allows the use of optical read-out techniques based on dynamic light scattering. Small detector cartridges arranged in 2D matrices are developed for the verification of a declared warhead without revealing its design. For this application, the enabling features of the emulsions are that bubbles formed at different times cannot be distinguished from each other, while the passive nature of the detectors avoids the susceptibility to electronic snooping and tampering. Large modules of emulsions are developed to detect the presence of shielded special nuclear materials hidden in cargo containers 'interrogated' with high energy X-rays. In this case, the enabling features of the emulsions are photon discrimination, a neutron detection threshold close to 3 MeV and a rate-insensitive read-out.

  8. Protective immunity and lack of histopathological damage two years after DNA vaccination against infectious hematopoietic necrosis virus in trout

    USGS Publications Warehouse

    Kurath, Gael; Garver, Kyle A.; Corbeil, Serge; Elliott, Diane G.; Anderson, Eric D.; LaPatra, Scott E.

    2006-01-01

    The DNA vaccine pIHNw-G encodes the glycoprotein of the fish rhabdovirus infectious hematopoietic necrosis virus (IHNV). Vaccine performance in rainbow trout was measured 3, 6, 13, 24, and 25 months after vaccination. At three months all fish vaccinated with 0.1 μg pIHNw-G had detectable neutralizing antibody (NAb) and they were completely protected from lethal IHNV challenge with a relative percent survival (RPS) of 100% compared to control fish. Viral challenges at 6, 13, 24, and 25 months post-vaccination showed protection with RPS values of 47–69%, while NAb seroprevalence declined to undetectable levels. Passive transfer experiments with sera from fish after two years post-vaccination were inconsistent but significant protection was observed in some cases. The long-term duration of protection observed here defined a third temporal phase in the immune response to IHNV DNA vaccination, characterized by reduced but significant levels of protection, and decline or absence of detectable NAb titers. Examination of multiple tissues showed an absence of detectable long-term histopathological damage due to DNA vaccination.

  9. A case of "order insensitivity"? Natural and artificial language processing in a man with primary progressive aphasia.

    PubMed

    Zimmerer, Vitor C; Varley, Rosemary A

    2015-08-01

    Processing of linear word order (linear configuration) is important for virtually all languages and essential to languages such as English which have little functional morphology. Damage to systems underpinning configurational processing may specifically affect word-order reliant sentence structures. We explore order processing in WR, a man with primary progressive aphasia (PPA). In a previous report, we showed how WR showed impaired processing of actives, which rely strongly on word order, but not passives where functional morphology signals thematic roles. Using the artificial grammar learning (AGL) paradigm, we examined WR's ability to process order in non-verbal, visual sequences and compared his profile to that of healthy controls, and aphasic participants with and without severe syntactic disorder. Results suggested that WR, like some other patients with severe syntactic impairment, was unable to detect linear configurational structure. The data are consistent with the notion that disruption of possibly domain-general linearization systems differentially affects processing of active and passive sentence structures. Further research is needed to test this account, and we suggest hypotheses for future studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Quantitative Frequency-Domain Passive Cavitation Imaging

    PubMed Central

    Haworth, Kevin J.; Bader, Kenneth B.; Rich, Kyle T.; Holland, Christy K.; Mast, T. Douglas

    2017-01-01

    Passive cavitation detection has been an instrumental technique for measuring cavitation dynamics, elucidating concomitant bioeffects, and guiding ultrasound therapies. Recently, techniques have been developed to create images of cavitation activity to provide investigators with a more complete set of information. These techniques use arrays to record and subsequently beamform received cavitation emissions, rather than processing emissions received on a single-element transducer. In this paper, the methods for performing frequency-domain delay, sum, and integrate passive imaging are outlined. The method can be applied to any passively acquired acoustic scattering or emissions, including cavitation emissions. In order to compare data across different systems, techniques for normalizing Fourier transformed data and converting the data to the acoustic energy received by the array are described. A discussion of hardware requirements and alternative imaging approaches are additionally outlined. Examples are provided in MATLAB. PMID:27992331

  11. Measuring, Understanding, and Responding to Covert Social Networks: Passive and Active Tomography

    DTIC Science & Technology

    2017-11-11

    practical algorithms for sociologically principled detection of small sub- networks. To detect “foreground” networks, we need two competing models...understanding of how to model “background” network clutter, leading to principled approaches to “foreground” sub-network detection. Before the MURI...no frameworks existed for network detection theory or goodness-of-fit, nor were models and algorithms coupled to sound sociological principles

  12. Identification of P/S-wave successions for application in microseismicity

    NASA Astrophysics Data System (ADS)

    Deflandre, J.-P.; Dubesset, M.

    1992-09-01

    Interpretation of P/S-wave successions is used in induced or passive microseismicity. It makes the location of microseismic events possible when the triangulation technique cannot be used. To improve the reliability of the method, we propose a technique that identifies the P/S-wave successions among recorded wave successions. A polarization software is used to verify the orthogonality between the P and S polarization axes. The polarization parameters are computed all along the 3-component acoustic signal. Then the algorithm detects time windows within which the signal polarization axis is perpendicular to the polarization axis of the wave in the reference time window (representative of the P wave). The technique is demonstrated for a synthetic event, and three application cases are presented. The first one corresponds to a calibration shot within which the arrivals of perpendicularly polarized waves are correctly detected in spite of their moderate amplitude. The second example presents a microseismic event recorded during gas withdrawal from an underground gas storage reservoir. The last example is chosen as a counter-example, concerning a microseismic event recorded during a hydraulic fracturing job. The detection algorithm reveals that, in this case, the wave succession does not correspond to a P/S one. This implies that such an event must not be located by the method based on the interpretation of a P/S-wave succession as no such a succession is confirmed.

  13. Passive acoustic monitoring to detect spawning in large-bodied catostomids

    USGS Publications Warehouse

    Straight, Carrie A.; Freeman, Byron J.; Freeman, Mary C.

    2014-01-01

    Documenting timing, locations, and intensity of spawning can provide valuable information for conservation and management of imperiled fishes. However, deep, turbid or turbulent water, or occurrence of spawning at night, can severely limit direct observations. We have developed and tested the use of passive acoustics to detect distinctive acoustic signatures associated with spawning events of two large-bodied catostomid species (River Redhorse Moxostoma carinatum and Robust Redhorse Moxostoma robustum) in river systems in north Georgia. We deployed a hydrophone with a recording unit at four different locations on four different dates when we could both record and observe spawning activity. Recordings captured 494 spawning events that we acoustically characterized using dominant frequency, 95% frequency, relative power, and duration. We similarly characterized 46 randomly selected ambient river noises. Dominant frequency did not differ between redhorse species and ranged from 172.3 to 14,987.1 Hz. Duration of spawning events ranged from 0.65 to 11.07 s, River Redhorse having longer durations than Robust Redhorse. Observed spawning events had significantly higher dominant and 95% frequencies than ambient river noises. We additionally tested software designed to automate acoustic detection. The automated detection configurations correctly identified 80–82% of known spawning events, and falsely indentified spawns 6–7% of the time when none occurred. These rates were combined over all recordings; rates were more variable among individual recordings. Longer spawning events were more likely to be detected. Combined with sufficient visual observations to ascertain species identities and to estimate detection error rates, passive acoustic recording provides a useful tool to study spawning frequency of large-bodied fishes that displace gravel during egg deposition, including several species of imperiled catostomids.

  14. Counter Unmanned Aerial Systems Testing: Evaluation of VIS SWIR MWIR and LWIR passive imagers.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birch, Gabriel Carlisle; Woo, Bryana Lynn

    This report contains analysis of unmanned aerial systems as imaged by visible, short-wave infrared, mid-wave infrared, and long-wave infrared passive devices. Testing was conducted at the Nevada National Security Site (NNSS) during the week of August 15, 2016. Target images in all spectral bands are shown and contrast versus background is reported. Calculations are performed to determine estimated pixels-on-target for detection and assessment levels, and the number of pixels needed to cover a hemisphere for detection or assessment at defined distances. Background clutter challenges are qualitatively discussed for different spectral bands, and low contrast scenarios are highlighted for long-wave infraredmore » imagers.« less

  15. Vision based techniques for rotorcraft low altitude flight

    NASA Technical Reports Server (NTRS)

    Sridhar, Banavar; Suorsa, Ray; Smith, Philip

    1991-01-01

    An overview of research in obstacle detection at NASA Ames Research Center is presented. The research applies techniques from computer vision to automation of rotorcraft navigation. The development of a methodology for detecting the range to obstacles based on the maximum utilization of passive sensors is emphasized. The development of a flight and image data base for verification of vision-based algorithms, and a passive ranging methodology tailored to the needs of helicopter flight are discussed. Preliminary results indicate that it is possible to obtain adequate range estimates except at regions close to the FOE. Closer to the FOE, the error in range increases since the magnitude of the disparity gets smaller, resulting in a low SNR.

  16. An RFI Detection Algorithm for Microwave Radiometers Using Sparse Component Analysis

    NASA Technical Reports Server (NTRS)

    Mohammed-Tano, Priscilla N.; Korde-Patel, Asmita; Gholian, Armen; Piepmeier, Jeffrey R.; Schoenwald, Adam; Bradley, Damon

    2017-01-01

    Radio Frequency Interference (RFI) is a threat to passive microwave measurements and if undetected, can corrupt science retrievals. The sparse component analysis (SCA) for blind source separation has been investigated to detect RFI in microwave radiometer data. Various techniques using SCA have been simulated to determine detection performance with continuous wave (CW) RFI.

  17. An airborne laser fluorosensor for the detection of oil on water

    NASA Technical Reports Server (NTRS)

    Kim, H. H.; Hickman, G. D.

    1973-01-01

    The successful operation of an airborne laser fluorosensor system is reported that makes it possible to detect and map surface oil, either of natural-seepage or spill origin, on large bodies of water. Preliminary results indicate that the sensitivity of the instrument exceeds that of conventional passive remote sensors currently available for oil spill detection.

  18. LWIR hyperspectral imaging application and detection of chemical precursors

    NASA Astrophysics Data System (ADS)

    Lavoie, Hugo; Thériault, Jean-Marc; Bouffard, François; Puckrin, Eldon; Dubé, Denis

    2012-10-01

    Detection and identification of Toxic industrial chemicals (TICs) represent a major challenge to protect and sustain first responder and public security. In this context, passive Hyperspectral Imaging (HSI) is a promising technology for the standoff detection and identification of chemical vapors emanating from a distant location. To investigate this method, the Department of National Defense and Public Safety Canada have mandated Defense Research and Development Canada (DRDC) - Valcartier to develop and test Very Long Wave Infrared (VLWIR) HSI sensors for standoff detection. The initial effort was focused to address the standoff detection and identification of toxic industrial chemicals (TICs), surrogates and precursors. Sensors such as the Improved Compact ATmospheric Sounding Interferometer (iCATSI) and the Multi-option Differential Detection and Imaging Fourier Spectrometer (MoDDIFS) were developed for this application. This paper presents the sensor developments and preliminary results of standoff detection and identification of TICs and precursors. The iCATSI and MoDDIFS sensors are based on the optical differential Fourier-transform infrared (FTIR) radiometric technology and are able to detect, spectrally resolve and identify small leak at ranges in excess of 1 km. Results from a series of trials in asymmetric threat type scenarios are reported. These results serve to establish the potential of passive standoff HSI detection of TICs, precursors and surrogates.

  19. Detection of Staphylococcus aureus enterotoxigenic strains in bovine raw milk by reversed passive latex agglutination and multiplex polymerase chain reaction.

    PubMed

    Mansour, Asmaa Samy; Wagih, Gad El-Said; Morgan, Sabry D; Elhariri, Mahmoud; El-Shabrawy, Mona A; Abuelnaga, Azza S M; Elgabry, E A

    2017-08-01

    This review gives an outline of the assessment of enterotoxigenic Staphylococcus aureus tainting levels in raw milk from different sources in Egypt and characterization of enterotoxigenic strains utilizing a technique in light of PCR to identify genes coding for the production of staphylococcal enterotoxin (SE). The obtained data were compared with results from the application of the reversed passive latex. Multiplex PCR and reversed passive latex agglutination (RPLA) were used. A total of 141 samples of raw milk (cow's milk=33, buffalo's milk=58, and bulk tank milk=50) were investigated for S. aureus contamination and tested for enterotoxin genes presence and toxin production. S. aureus was detected in 23 (16.3%) samples phenotypically and genotypically by amplification of nuc gene. The S. aureus isolates were investigated for SEs genes ( sea to see ) by multiplex PCR and the toxin production by these isolates was screened by RPLA. SEs genes were detected in six isolates (26.1%) molecularly; see was the most observed gene where detected in all isolates, two isolates harbored seb , and two isolates harbored sec . According to RPLA, three isolates produced SEB and SEC. The study revealed the widespread of S. aureus strains caring genes coding for toxins. The real significance of the presence of these strains or its toxins in raw milk and their possible impact a potential hazard for staphylococcal food poisoning by raw milk consumption. Therefore, detection of enterotoxigenic S. aureus strains in raw milk is necessary for consumer safety.

  20. Evaluation of surveillance methods for staphylococcal toxic shock syndrome.

    PubMed

    Lesher, Lindsey; Devries, Aaron; Danila, Richard; Lynfield, Ruth

    2009-05-01

    We compared passive surveillance and International Classification of Diseases, 9th Revision, codes for completeness of staphylococcal toxic shock syndrome (TSS) surveillance in the Minneapolis-St. Paul area, Minnesota, USA. TSS-specific codes identified 55% of cases compared with 30% by passive surveillance and were more sensitive (p = 0.0005, McNemar chi2 12.25).

  1. Evaluation of Surveillance Methods for Staphylococcal Toxic Shock Syndrome

    PubMed Central

    DeVries, Aaron; Danila, Richard; Lynfield, Ruth

    2009-01-01

    We compared passive surveillance and International Classification of Diseases, 9th Revision, codes for completeness of staphylococcal toxic shock syndrome (TSS) surveillance in the Minneapolis–St. Paul area, Minnesota, USA. TSS-specific codes identified 55% of cases compared with 30% by passive surveillance and were more sensitive (p = 0.0005, McNemar χ2 12.25). PMID:19402965

  2. RATE OF TCE DEGRADATION IN PASSIVE REACTIVE BARRIERS CONSTRUCTED WITH PLANT MULCH (BIOWALLS)

    EPA Science Inventory

    This presentation reviews a case study at Altus AFB on the extent of treatment of TCE in a passive reactive barrier constructed with plant mulch. It presents data from a tracer test to estimate the rate of ground water flow at the site, and the residence time of water and TCE in...

  3. Processing and characterization of device solder interconnection and module attachment for power electronics modules

    NASA Astrophysics Data System (ADS)

    Haque, Shatil

    This research is focused on the processing of an innovative three-dimensional packaging architecture for power electronics building blocks with soldered device interconnections and subsequent characterization of the module's critical interfaces. A low-cost approach termed metal posts interconnected parallel plate structure (MPIPPS) was developed for packaging high-performance modules of power electronics building blocks (PEBB). The new concept implemented direct bonding of copper posts, not wire bonding of fine aluminum wires, to interconnect power devices as well as joining the different circuit planes together. We have demonstrated the feasibility of this packaging approach by constructing PEBB modules (consisting of Insulated Gate Bipolar Transistors (IGBTs), diodes, and a few gate driver elements and passive components). In the 1st phase of module fabrication with IGBTs with Si3N 4 passivation, we had successfully fabricated packaged devices and modules using the MPIPPS technique. These modules were tested electrically and thermally, and they operated at pulse-switch and high power stages up to 6kW. However, in the 2nd phase of module fabrication with polyimide passivated devices, we experienced significant yield problems due to metallization difficulties of these devices. The under-bump metallurgy scheme for the development of a solderable interface involved sputtering of Ti-Ni-Cu and Cr-Cu, and an electroless deposition of Zn-Ni-Au metallization. The metallization process produced excellent yield in the case of Si3N4 passivated devices. However, under the same metallization schemes, devices with a polyimide passivation exhibited inconsistent electrical contact resistance. We found that organic contaminants such as hydrocarbons remain in the form of thin monolayers on the surface, even in the case of as-received devices from the manufacturer. Moreover, in the case of polyimide passivated devices, plasma cleaning introduced a few carbon constituents on the surface, which was not observed in the case of Si3N4 passivated devices. X-Ray Photoelectron Spectroscopy (XPS) Spectra showed evidence of possible carbon contaminants, such as carbide (˜282.9eV) and graphite (˜284.3eV) on the surface at binding energies below the binding energy of the hydrocarbon peak (C 1s at 285eV). Whereas above the hydrocarbon peak energy level, carbon-nitrogen compounds, single bond carbon compounds (˜285.9eV) and double bond carbon compounds (˜288.5eV) were evident. The majority of the carbon composition on the pad surface was associated with hydrocarbons, which were hydrophobic in nature, thus making the device contact pad less wettable. (Abstract shortened by UMI.)

  4. Passivity analysis of memristor-based impulsive inertial neural networks with time-varying delays.

    PubMed

    Wan, Peng; Jian, Jigui

    2018-03-01

    This paper focuses on delay-dependent passivity analysis for a class of memristive impulsive inertial neural networks with time-varying delays. By choosing proper variable transformation, the memristive inertial neural networks can be rewritten as first-order differential equations. The memristive model presented here is regarded as a switching system rather than employing the theory of differential inclusion and set-value map. Based on matrix inequality and Lyapunov-Krasovskii functional method, several delay-dependent passivity conditions are obtained to ascertain the passivity of the addressed networks. In addition, the results obtained here contain those on the passivity for the addressed networks without impulse effects as special cases and can also be generalized to other neural networks with more complex pulse interference. Finally, one numerical example is presented to show the validity of the obtained results. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  5. Malaria profiles and challenges in artemisinin resistance containment in Myanmar.

    PubMed

    Nwe, Thet Wai; Oo, Tin; Wai, Khin Thet; Zhou, Shuisen; van Griensven, Johan; Chinnakali, Palanivel; Shah, Safieh; Thi, Aung

    2017-04-25

    This study examined evolving malaria profiles from January, 2010 to December, 2014 to evaluate achievements and challenges of implementing measures to prevent and control spread of artemisinin resistance in Myanmar. Using National Malaria Control Programme (NMCP) data, a cross-sectional descriptive study of 52 townships in artemisinin-resistant containment areas in Myanmar was conducted. Annual program data were analysed, and trends over time are graphically presented. In the 52 study townships populated by 8.7 million inhabitants, malaria incidence showed a decreasing trend from 10.54 per 1 000 population in 2010 to 2.53 in 2014, and malaria mortalities also decreased from 1.83 per 100 000 population in 2010 to 0.17 in 2014. The proportion of confirmed to total tested malaria cases also decreased from 6 to 1%, while identification of cases improved. All cases from all parasites species, including Plasmodium falciparum, decreased. Coverage of LLIN (long-lasting insecticidal net)/ITN (insecticide-treated mosquito nets) and indoor residual spraying (IRS) was high in targeted areas with at-risk persons, even though the total population was not covered. In addition to passive case detection (PCD), active case detection (ACD) was conducted in hard-to-reach areas and worksites where mobile migrant populations were present. ACD improved in most areas from 2012 to 2014, but continues to need to be strengthened. The findings provide useful data on the malaria situation in artemisinin-resistant initiative areas, which may be useful for the NMCP to meet its elimination goal. These profiles could contribute to better planning, implementation, and evaluation of intervention activities.

  6. Real-Time Adaptation of Decision Thresholds in Sensor Networks for Detection of Moving Targets (PREPRINT)

    DTIC Science & Technology

    2010-01-01

    target kinematics for multiple sensor detections is referred to as the track - before - detect strategy, and is commonly adopted in multi-sensor surveillance...of moving targets. Wettergren [4] presented an application of track - before - detect strategies to undersea distributed sensor networks. In de- signing...the deployment of a distributed passive sensor network that employs this track - before - detect procedure, it is impera- tive that the placement of

  7. Effects of musical training on sound pattern processing in high-school students.

    PubMed

    Wang, Wenjung; Staffaroni, Laura; Reid, Errold; Steinschneider, Mitchell; Sussman, Elyse

    2009-05-01

    Recognizing melody in music involves detection of both the pitch intervals and the silence between sequentially presented sounds. This study tested the hypothesis that active musical training in adolescents facilitates the ability to passively detect sequential sound patterns compared to musically non-trained age-matched peers. Twenty adolescents, aged 15-18 years, were divided into groups according to their musical training and current experience. A fixed order tone pattern was presented at various stimulus rates while electroencephalogram was recorded. The influence of musical training on passive auditory processing of the sound patterns was assessed using components of event-related brain potentials (ERPs). The mismatch negativity (MMN) ERP component was elicited in different stimulus onset asynchrony (SOA) conditions in non-musicians than musicians, indicating that musically active adolescents were able to detect sound patterns across longer time intervals than age-matched peers. Musical training facilitates detection of auditory patterns, allowing the ability to automatically recognize sequential sound patterns over longer time periods than non-musical counterparts.

  8. Towards a precise test for malaria diagnosis in the Brazilian Amazon: comparison among field microscopy, a rapid diagnostic test, nested PCR, and a computational expert system based on artificial neural networks

    PubMed Central

    2010-01-01

    Background Accurate malaria diagnosis is mandatory for the treatment and management of severe cases. Moreover, individuals with asymptomatic malaria are not usually screened by health care facilities, which further complicates disease control efforts. The present study compared the performances of a malaria rapid diagnosis test (RDT), the thick blood smear method and nested PCR for the diagnosis of symptomatic malaria in the Brazilian Amazon. In addition, an innovative computational approach was tested for the diagnosis of asymptomatic malaria. Methods The study was divided in two parts. For the first part, passive case detection was performed in 311 individuals with malaria-related symptoms from a recently urbanized community in the Brazilian Amazon. A cross-sectional investigation compared the diagnostic performance of the RDT Optimal-IT, nested PCR and light microscopy. The second part of the study involved active case detection of asymptomatic malaria in 380 individuals from riverine communities in Rondônia, Brazil. The performances of microscopy, nested PCR and an expert computational system based on artificial neural networks (MalDANN) using epidemiological data were compared. Results Nested PCR was shown to be the gold standard for diagnosis of both symptomatic and asymptomatic malaria because it detected the major number of cases and presented the maximum specificity. Surprisingly, the RDT was superior to microscopy in the diagnosis of cases with low parasitaemia. Nevertheless, RDT could not discriminate the Plasmodium species in 12 cases of mixed infections (Plasmodium vivax + Plasmodium falciparum). Moreover, the microscopy presented low performance in the detection of asymptomatic cases (61.25% of correct diagnoses). The MalDANN system using epidemiological data was worse that the light microscopy (56% of correct diagnoses). However, when information regarding plasma levels of interleukin-10 and interferon-gamma were inputted, the MalDANN performance sensibly increased (80% correct diagnoses). Conclusions An RDT for malaria diagnosis may find a promising use in the Brazilian Amazon integrating a rational diagnostic approach. Despite the low performance of the MalDANN test using solely epidemiological data, an approach based on neural networks may be feasible in cases where simpler methods for discriminating individuals below and above threshold cytokine levels are available. PMID:20459613

  9. Towards a precise test for malaria diagnosis in the Brazilian Amazon: comparison among field microscopy, a rapid diagnostic test, nested PCR, and a computational expert system based on artificial neural networks.

    PubMed

    Andrade, Bruno B; Reis-Filho, Antonio; Barros, Austeclino M; Souza-Neto, Sebastião M; Nogueira, Lucas L; Fukutani, Kiyoshi F; Camargo, Erney P; Camargo, Luís M A; Barral, Aldina; Duarte, Angelo; Barral-Netto, Manoel

    2010-05-06

    Accurate malaria diagnosis is mandatory for the treatment and management of severe cases. Moreover, individuals with asymptomatic malaria are not usually screened by health care facilities, which further complicates disease control efforts. The present study compared the performances of a malaria rapid diagnosis test (RDT), the thick blood smear method and nested PCR for the diagnosis of symptomatic malaria in the Brazilian Amazon. In addition, an innovative computational approach was tested for the diagnosis of asymptomatic malaria. The study was divided in two parts. For the first part, passive case detection was performed in 311 individuals with malaria-related symptoms from a recently urbanized community in the Brazilian Amazon. A cross-sectional investigation compared the diagnostic performance of the RDT Optimal-IT, nested PCR and light microscopy. The second part of the study involved active case detection of asymptomatic malaria in 380 individuals from riverine communities in Rondônia, Brazil. The performances of microscopy, nested PCR and an expert computational system based on artificial neural networks (MalDANN) using epidemiological data were compared. Nested PCR was shown to be the gold standard for diagnosis of both symptomatic and asymptomatic malaria because it detected the major number of cases and presented the maximum specificity. Surprisingly, the RDT was superior to microscopy in the diagnosis of cases with low parasitaemia. Nevertheless, RDT could not discriminate the Plasmodium species in 12 cases of mixed infections (Plasmodium vivax + Plasmodium falciparum). Moreover, the microscopy presented low performance in the detection of asymptomatic cases (61.25% of correct diagnoses). The MalDANN system using epidemiological data was worse that the light microscopy (56% of correct diagnoses). However, when information regarding plasma levels of interleukin-10 and interferon-gamma were inputted, the MalDANN performance sensibly increased (80% correct diagnoses). An RDT for malaria diagnosis may find a promising use in the Brazilian Amazon integrating a rational diagnostic approach. Despite the low performance of the MalDANN test using solely epidemiological data, an approach based on neural networks may be feasible in cases where simpler methods for discriminating individuals below and above threshold cytokine levels are available.

  10. Passive margins getting squeezed in the mantle convection vice

    NASA Astrophysics Data System (ADS)

    Yamato, Philippe; Husson, Laurent; Becker, Thorsten W.; Pedoja, Kevin

    2014-05-01

    Passive margins often exhibit uplift, exhumation and tectonic inversion. We speculate that the compression in the lithosphere gradually increased during the Cenozoic. In the same time, the many mountain belts at active margins that accompany this event seem readily witness this increase. However, how that compression increase affects passive margins remains unclear. In order to address this issue, we design a 2D viscous numerical model wherein a lithospheric plate rests above a weaker mantle. It is driven by a mantle conveyor belt, alternatively excited by a lateral downwelling on one side, an upwelling on the other side, or both simultaneously. The lateral edges of the plate are either free or fixed, representing the cases of free convergence, and collision or slab anchoring, respectively. This distinction changes the upper boundary condition for mantle circulation and, as a consequence, the stress field. Our results show that between these two regimes, the flow pattern transiently evolves from a free-slip convection mode towards a no-slip boundary condition above the upper mantle. In the second case, the lithosphere is highly stressed horizontally and deforms. For an equivalent bulk driving force, compression increases drastically at passive margins provided that upwellings are active. Conversely, if downwellings alone are activated, compression occurs at short distances from the trench and extension prevails elsewhere. These results are supported by Earth-like 3D spherical models that reveal the same pattern, where active upwellings are required to excite passive margins compression. These results support the idea that compression at passive margins, is the response to the underlying mantle flow, that is increasingly resisted by the Cenozoic collisions.

  11. Spatio-temporal variation in click production rates of beaked whales: Implications for passive acoustic density estimation.

    PubMed

    Warren, Victoria E; Marques, Tiago A; Harris, Danielle; Thomas, Len; Tyack, Peter L; Aguilar de Soto, Natacha; Hickmott, Leigh S; Johnson, Mark P

    2017-03-01

    Passive acoustic monitoring has become an increasingly prevalent tool for estimating density of marine mammals, such as beaked whales, which vocalize often but are difficult to survey visually. Counts of acoustic cues (e.g., vocalizations), when corrected for detection probability, can be translated into animal density estimates by applying an individual cue production rate multiplier. It is essential to understand variation in these rates to avoid biased estimates. The most direct way to measure cue production rate is with animal-mounted acoustic recorders. This study utilized data from sound recording tags deployed on Blainville's (Mesoplodon densirostris, 19 deployments) and Cuvier's (Ziphius cavirostris, 16 deployments) beaked whales, in two locations per species, to explore spatial and temporal variation in click production rates. No spatial or temporal variation was detected within the average click production rate of Blainville's beaked whales when calculated over dive cycles (including silent periods between dives); however, spatial variation was detected when averaged only over vocal periods. Cuvier's beaked whales exhibited significant spatial and temporal variation in click production rates within vocal periods and when silent periods were included. This evidence of variation emphasizes the need to utilize appropriate cue production rates when estimating density from passive acoustic data.

  12. Case Study: Videogame Distraction Reduces Behavioral Distress in a Preschool-Aged Child Undergoing Repeated Burn Dressing Changes: A Single-Subject Design

    PubMed Central

    Sil, Soumitri; Burns, Andrew J.

    2013-01-01

    Objective This single-subject design study evaluated the feasibility and efficacy of passive and interactive videogame distraction on behavioral distress for a preschool-aged child receiving repeated burn dressing changes. Method A 4-year-old girl underwent 3 baseline and 10 videogame distraction sessions (5 passive and 5 interactive) using a restricted alternating treatments design. Observed behavioral distress was coded, and parents and nurses rated the child’s distress and cooperative behavior. Results Relative to baseline, behavioral distress decreased and cooperative behavior increased immediately after the onset of videogame distraction. Single Case Randomization Tests revealed significantly lower behavioral distress and greater cooperation during interactive videogame distraction relative to passive videogame distraction. Conclusions Interactive videogame distraction appears to be a feasible and effective pain management strategy for a preschool-aged child undergoing repeated painful medical procedures. PMID:23248343

  13. Rapid, sensitive, and reusable detection of glucose by a robust radiofrequency integrated passive device biosensor chip.

    PubMed

    Kim, Nam-Young; Adhikari, Kishor Kumar; Dhakal, Rajendra; Chuluunbaatar, Zorigt; Wang, Cong; Kim, Eun-Soo

    2015-01-15

    Tremendous demands for sensitive and reliable label-free biosensors have stimulated intensive research into developing miniaturized radiofrequency resonators for a wide range of biomedical applications. Here, we report the development of a robust, reusable radiofrequency resonator based integrated passive device biosensor chip fabricated on a gallium arsenide substrate for the detection of glucose in water-glucose solutions and sera. As a result of the highly concentrated electromagnetic energy between the two divisions of an intertwined spiral inductor coupled with an interdigital capacitor, the proposed glucose biosensor chip exhibits linear detection ranges with high sensitivity at center frequency. This biosensor, which has a sensitivity of up to 199 MHz/mgmL(-1) and a short response time of less than 2 sec, exhibited an ultralow detection limit of 0.033 μM and a reproducibility of 0.61% relative standard deviation. In addition, the quantities derived from the measured S-parameters, such as the propagation constant (γ), impedance (Z), resistance (R), inductance (L), conductance (G) and capacitance (C), enabled the effective multi-dimensional detection of glucose.

  14. Chemistry, metabolism, and toxicology of cannabis: clinical implications.

    PubMed

    Sharma, Priyamvada; Murthy, Pratima; Bharath, M M Srinivas

    2012-01-01

    Cannabis is one of the most widely abused substances throughout the world. The primary psychoactive constituent of cannabis, delta 9-tetrahydrocannabinol (▵(9_)THC), produces a myriad of pharmacological effects in animals and humans. Although it is used as a recreational drug, it can potentially lead to dependence and behavioral disturbances and its heavy use may increase the risk for psychotic disorders.Many studies that endeavor to understand the mechanism of action of cannabis concentrate on pharmacokinetics and pharmacodynamics of cannabinoids in humans. However, there is limited research on the chronic adverse effects and retention of cannabinoids in human subjects.Cannabis can be detected in body fluids following exposure through active/passive inhalation and exposure through breastfeeding. Cannabis detection is directly dependent on accurate analytical procedures for detection of metabolites and verification of recent use.In this review, an attempt has been made to summarize the properties of cannabis and its derivatives, and to discuss the implications of its use with emphasis on bioavailability, limit of detection, carry over period and passive inhalation, important factors for detection and diagnosis.

  15. Rapid, Sensitive, and Reusable Detection of Glucose by a Robust Radiofrequency Integrated Passive Device Biosensor Chip

    PubMed Central

    Kim, Nam-Young; Adhikari, Kishor Kumar; Dhakal, Rajendra; Chuluunbaatar, Zorigt; Wang, Cong; Kim, Eun-Soo

    2015-01-01

    Tremendous demands for sensitive and reliable label-free biosensors have stimulated intensive research into developing miniaturized radiofrequency resonators for a wide range of biomedical applications. Here, we report the development of a robust, reusable radiofrequency resonator based integrated passive device biosensor chip fabricated on a gallium arsenide substrate for the detection of glucose in water-glucose solutions and sera. As a result of the highly concentrated electromagnetic energy between the two divisions of an intertwined spiral inductor coupled with an interdigital capacitor, the proposed glucose biosensor chip exhibits linear detection ranges with high sensitivity at center frequency. This biosensor, which has a sensitivity of up to 199 MHz/mgmL−1 and a short response time of less than 2 sec, exhibited an ultralow detection limit of 0.033 μM and a reproducibility of 0.61% relative standard deviation. In addition, the quantities derived from the measured S-parameters, such as the propagation constant (γ), impedance (Z), resistance (R), inductance (L), conductance (G) and capacitance (C), enabled the effective multi-dimensional detection of glucose. PMID:25588958

  16. Chemistry, Metabolism, and Toxicology of Cannabis: Clinical Implications

    PubMed Central

    Murthy, Pratima; Bharath, M.M. Srinivas

    2012-01-01

    Cannabis is one of the most widely abused substances throughout the world. The primary psychoactive constituent of cannabis, delta 9-tetrahydrocannabinol (▵9_THC), produces a myriad of pharmacological effects in animals and humans. Although it is used as a recreational drug, it can potentially lead to dependence and behavioral disturbances and its heavy use may increase the risk for psychotic disorders. Many studies that endeavor to understand the mechanism of action of cannabis concentrate on pharmacokinetics and pharmacodynamics of cannabinoids in humans. However, there is limited research on the chronic adverse effects and retention of cannabinoids in human subjects. Cannabis can be detected in body fluids following exposure through active/passive inhalation and exposure through breastfeeding. Cannabis detection is directly dependent on accurate analytical procedures for detection of metabolites and verification of recent use. In this review, an attempt has been made to summarize the properties of cannabis and its derivatives, and to discuss the implications of its use with emphasis on bioavailability, limit of detection, carry over period and passive inhalation, important factors for detection and diagnosis. PMID:23408483

  17. Influence of Co content on the biocompatibility and bio-corrosion of super ferritic stainless steels

    NASA Astrophysics Data System (ADS)

    Yoo, Y. R.; Jang, S. G.; Nam, H. S.; Shim, G. T.; Cho, H. H.; Kim, J. G.; Kim, Y. S.

    2008-12-01

    Bio-metals require high corrosion resistance, because their biocompatibility is closely related to this parameter. Bio-metals release metal ions into the human body, leading to deleterious effects. Allergies, dermatitis, and asthma are the predominant systemic effects resulting in the human body. In particular, Ni is one of the most common causes of allergic contact dermatitis. In the present work, we designed new ferritic stainless steels wherein Ni is replaced with Co under consideration of allergic respondes and microstructural stability. This work focuses on the effect of Co content on the biocompatibility and corrosion resistance of high PRE super ferritic stainless steels in bio-solution and acidic chloride solution. In the case of the acidic chloride solution, with increasing Co content in the ferritic stainless steels, passive current density increased and critical pitting temperature (CPT) decreased. Also, in the passive state, AC impedance and repassivation rate were reduced. These results are attributed to the thermodynamic stability of cobalt ions, as indicated in the EpH diagram for a Co-H2O system. However, in the case of bio-solutions, with increasing Co content of the alloys, the passive current density decreased. AC impedance and repassivation rate meanwhile increased in the passive state. This is due to the increased ratios of Cr2O3/Cr(OH)3 and [Metal Oxide]/Metal + Metal Oxide] of the passive film formed in bio-solution.

  18. Analysis and suppression of passive noise in surface microseismic data

    NASA Astrophysics Data System (ADS)

    Forghani-Arani, Farnoush

    Surface microseismic surveys are gaining popularity in monitoring the hydraulic fracturing process. The effectiveness of these surveys, however, is strongly dependent on the signal-to-noise ratio of the acquired data. Cultural and industrial noise generated during hydraulic fracturing operations usually dominate the data, thereby decreasing the effectiveness of using these data in identifying and locating microseismic events. Hence, noise suppression is a critical step in surface microseismic monitoring. In this thesis, I focus on two important aspects in using surface-recorded microseismic seismic data: first, I take advantage of the unwanted surface noise to understand the characteristics of these noise and extract information about the propagation medium from the noise; second, I propose effective techniques to suppress the surface noise while preserving the waveforms that contain information about the source of microseisms. Automated event identification on passive seismic data using only a few receivers is challenging especially when the record lengths span over long durations of time. I introduce an automatic event identification algorithm that is designed specifically for detecting events in passive data acquired with a small number of receivers. I demonstrate that the conventional STA/LTA (Short-term Average/Long-term Average) algorithm is not sufficiently effective in event detection in the common case of low signal-to-noise ratio. With a cross-correlation based method as an extension of the STA/LTA algorithm, even low signal-to-noise events (that were not detectable with conventional STA/LTA) were revealed. Surface microseismic data contains surface-waves (generated primarily from hydraulic fracturing activities) and body-waves in the form of microseismic events. It is challenging to analyze the surface-waves on the recorded data directly because of the randomness of their source and their unknown source signatures. I use seismic interferometry to extract the surface-wave arrivals. Interferometry is a powerful tool to extract waves (including body-wave and surface-waves) that propagate from any receiver in the array (called a pseudo source) to the other receivers across the array. Since most of the noise sources in surface microseismic data lie on the surface, seismic interferometry yields pseudo source gathers dominated by surface-wave energy. The dispersive characteristics of these surface-waves are important properties that can be used to extract information necessary for suppressing these waves. I demonstrate the application of interferometry to surface passive data recorded during the hydraulic fracturing operation of a tight gas reservoir and extract the dispersion properties of surface-waves corresponding to a pseudo-shot gather. Comparison of the dispersion characteristics of the surface waves from the pseudo-shot gather with that of an active shot-gather shows interesting similarities and differences. The dispersion character (e.g. velocity change with frequency) of the fundamental mode was observed to have the same behavior for both the active and passive data. However, for the higher mode surface-waves, the dispersion properties are extracted at different frequency ranges. Conventional noise suppression techniques in passive data are mostly stacking-based that rely on enforcing the amplitude of the signal by stacking the waveforms at the receivers and are unable to preserve the waveforms at the individual receivers necessary for estimating the microseismic source location and source mechanism. Here, I introduce a technique based on the tau - p transform, that effectively identifies and separates microseismic events from surface-wave noise in the tau -p domain. This technique is superior to conventional stacking-based noise suppression techniques, because it preserves the waveforms at individual receivers. Application of this methodology to microseismic events with isotropic and double-couple source mechanism, show substantial improvement in the signal-to-noise ratio. Imaging of the processed field data also show improved imaging of the hypocenter location of the microseismic source. In the case of double-couple source mechanism, I suggest two approaches for unifying the polarities at the receivers, a cross-correlation approach and a semblance-based prediction approach. The semblance-based approach is more effective at unifying the polarities, especially for low signal-to-noise ratio data.

  19. Cardiomyopathy in captive African hedgehogs (Atelerix albiventris).

    PubMed

    Raymond, J T; Garner, M M

    2000-09-01

    From 1994 to 1999, 16 captive African hedgehogs (Atelerix albiventris), from among 42 necropsy cases, were diagnosed with cardiomyopathy. The incidence of cardiomyopathy in this study population was 38%. Fourteen of 16 hedgehogs with cardiomyopathy were males and all hedgehogs were adult (>1 year old). Nine hedgehogs exhibited 1 or more of the following clinical signs before death: heart murmur, lethargy, icterus, moist rales, anorexia, dyspnea, dehydration, and weight loss. The remaining 7 hedgehogs died without premonitory clinical signs. Gross findings were cardiomegaly (6 cases), hepatomegaly (5 cases), pulmonary edema (5 cases), pulmonary congestion (4 cases), hydrothorax (3 cases), pulmonary infarct (1 case), renal infarcts (1 case), ascites (1 case), and 5 cases showed no changes. Histologic lesions were found mainly within the left ventricular myocardium and consisted primarily of myodegeneration, myonecrosis, atrophy, hypertrophy, and disarray of myofibers. All hedgehogs with cardiomyopathy had myocardial fibrosis, myocardial edema, or both. Other common histopathologic findings were acute and chronic passive congestion of the lungs, acute passive congestion of the liver, renal tubular necrosis, vascular thrombosis, splenic extramedullary hematopoiesis, and hepatic lipidosis. This is the first report of cardiomyopathy in African hedgehogs.

  20. Passive solar design strategies: Remodeling guidelines for conserving energy at home

    NASA Astrophysics Data System (ADS)

    The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler's typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house's need for purchased heating (and in some cases, cooling) energy - but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical, and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive Solar Design Strategies: Remodeling Guidelines For Conserving Energy At Home is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: the guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; the worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; and the worked example demonstrates how to complete the worksheets for a typical residence.

  1. Damage detection and isolation via autocorrelation: a step toward passive sensing

    NASA Astrophysics Data System (ADS)

    Chang, Y. S.; Yuan, F. G.

    2018-03-01

    Passive sensing technique may eliminate the need of expending power from actuators and thus provide a means of developing a compact and simple structural health monitoring system. More importantly, it may provide a solution for monitoring the aircraft subjected to environmental loading from air flow during operation. In this paper, a non-contact auto-correlation based technique is exploited as a feasibility study for passive sensing application to detect damage and isolate the damage location. Its theoretical basis bears some resemblance to reconstructing Green's function from diffusive wavefield through cross-correlation. Localized high pressure air from air compressor are randomly and continuously applied on the one side surface of the aluminum panels through the air blow gun. A laser Doppler vibrometer (LDV) was used to scan a 90 mm × 90 mm area to create a 6 × 6 2D-array signals from the opposite side of the panels. The scanned signals were auto-correlated to reconstruct a "selfimpulse response" (or Green's function). The premise for stably reconstructing the accurate Green's function requires long sensing times. For a 609.6 mm × 609.6 mm flat aluminum panel, the sensing times roughly at least four seconds is sufficient to establish converged Green's function through correlation. For the integral stiffened aluminum panel, the geometrical features of the panel expedite the formation of the diffusive wavefield and thus shorten the sensing times. The damage is simulated by gluing a magnet onto the panels. Reconstructed Green's functions (RGFs) are used for damage detection and damage isolation based on an imaging condition with mean square deviation of the RGFs from the pristine and the damaged structure and the results are shown in color maps. The auto-correlation based technique is shown to consistently detect the simulated damage, image and isolate the damage in the structure subjected to high pressure air excitation. This technique may be transformed into passive sensing applied on the aircraft during operation.

  2. 4-D imaging of seepage in earthen embankments with time-lapse inversion of self-potential data constrained by acoustic emissions localization

    NASA Astrophysics Data System (ADS)

    Rittgers, J. B.; Revil, A.; Planes, T.; Mooney, M. A.; Koelewijn, A. R.

    2015-02-01

    New methods are required to combine the information contained in the passive electrical and seismic signals to detect, localize and monitor hydromechanical disturbances in porous media. We propose a field experiment showing how passive seismic and electrical data can be combined together to detect a preferential flow path associated with internal erosion in a Earth dam. Continuous passive seismic and electrical (self-potential) monitoring data were recorded during a 7-d full-scale levee (earthen embankment) failure test, conducted in Booneschans, Netherlands in 2012. Spatially coherent acoustic emissions events and the development of a self-potential anomaly, associated with induced concentrated seepage and internal erosion phenomena, were identified and imaged near the downstream toe of the embankment, in an area that subsequently developed a series of concentrated water flows and sand boils, and where liquefaction of the embankment toe eventually developed. We present a new 4-D grid-search algorithm for acoustic emissions localization in both time and space, and the application of the localization results to add spatially varying constraints to time-lapse 3-D modelling of self-potential data in the terms of source current localization. Seismic signal localization results are utilized to build a set of time-invariant yet spatially varying model weights used for the inversion of the self-potential data. Results from the combination of these two passive techniques show results that are more consistent in terms of focused ground water flow with respect to visual observation on the embankment. This approach to geophysical monitoring of earthen embankments provides an improved approach for early detection and imaging of the development of embankment defects associated with concentrated seepage and internal erosion phenomena. The same approach can be used to detect various types of hydromechanical disturbances at larger scales.

  3. Assessment of soil-gas and groundwater contamination at the Gibson Road landfill, Fort Gordon, Georgia, 2011

    USGS Publications Warehouse

    Falls, W. Fred; Caldwell, Andral W.; Guimaraes, Wladmir G.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2012-01-01

    Soil-gas and groundwater assessments were conducted at the Gibson Road landfill in 201 to provide screening-level environmental contamination data to supplement the data collected during previous environmental studies at the landfill. Passive samplers were used in both assessments to detect volatile and semivolatile organic compounds and polycyclic aromatic hydrocarbons in soil gas and groundwater. A total of 56 passive samplers were deployed in the soil in late July and early August for the soil-gas assessment. Total petroleum hydrocarbons (TPH) were detected at masses greater than the method detection level of 0.02 microgram in all samplers and masses greater than 2.0 micrograms in 13 samplers. Three samplers located between the landfill and a nearby wetland had TPH masses greater than 20 micrograms. Diesel was detected in 28 of the 56 soil-gas samplers. Undecane, tridecane, and pentadecane were detected, but undecane was the most common diesel compound with 23 detections. Only five detections exceeded a combined diesel mass of 0.10 microgram, including the highest mass of 0.27 microgram near the wetland. Toluene was detected in only five passive samplers, including masses of 0.65 microgram near the wetland and 0.85 microgram on the southwestern side of the landfill. The only other gasoline-related compound detected was octane in two samplers. Naphthalene was detected in two samplers in the gully near the landfill and two samplers along the southwestern side of the landfill, but had masses less than or equal to 0.02 microgram. Six samplers located southeast of the landfill had detections of chlorinated compounds, including one perchloroethene detections (0.04 microgram) and five chloroform detections (0.05 to0.08 microgram). Passive samplers were deployed and recovered on August 8, 2011, in nine monitoring wells along the southwestern, southeastern and northeastern sides of the landfill and down gradient from the eastern corner of the landfill. Six of the nine samplers had TPH concentrations greater than 100 micrograms per liter. TPH concentrations declined from 320 micrograms per liter in a sampler near the landfill to 18 micrograms in a sampler near the wetland. Five of the samplers had detections of one or more diesel compounds but detections of individual diesel compounds had concentrations below a method detection level of 0.01 microgram per liter. Benzene was detected in three samplers and exceeded the national primary drinking-water standard of 5 micrograms per liter set by the U.S. Environmental Protection Agency. The concentrations of benzene, and therefore BTEX, were 6.1 micrograms per liter in the sampler near the eastern corner of the landfill, 27 micrograms per liter in the sampler near the wetland, and 37 micrograms per liter in the sampler at the southern corner of the landfill. Nonfuel-related compounds were detected in the four wells that are aligned between the eastern corner of the landfill and the wetland. The sampler deployed nearest the eastern corner of the landfill had the greatest number of detected organic compounds and had the only detections of two trimethylbenzene compounds, naphthalene, 2-methyl naphthalene, and 1,4-dichlorobenzene. The two up gradient samplers had the greatest number of chlorinated compounds with five compounds each, compared to detections of four compounds and one compound in the two down gradient samplers. All four samplers had detections of 1,1-dichloroethane which ranged from 42 to 1,300 micrograms per liter. Other detections of chlorinated compounds included trichloroethene, perchloroethene, cis-1,2-dichloroethene, 1,1,1-trichloroethane and chloroform.

  4. Variation in detection among passive infrared triggered-cameras used in wildlife research

    USGS Publications Warehouse

    Damm, Philip E.; Grand, James B.; Barnett, Steven W.

    2010-01-01

    Precise and accurate estimates of demographics such as age structure, productivity, and density are necessary in determining habitat and harvest management strategies for wildlife populations. Surveys using automated cameras are becoming an increasingly popular tool for estimating these parameters. However, most camera studies fail to incorporate detection probabilities, leading to parameter underestimation. The objective of this study was to determine the sources of heterogeneity in detection for trail cameras that incorporate a passive infrared (PIR) triggering system sensitive to heat and motion. Images were collected at four baited sites within the Conecuh National Forest, Alabama, using three cameras at each site operating continuously over the same seven-day period. Detection was estimated for four groups of animals based on taxonomic group and body size. Our hypotheses of detection considered variation among bait sites and cameras. The best model (w=0.99) estimated different rates of detection for each camera in addition to different detection rates for four animal groupings. Factors that explain this variability might include poor manufacturing tolerances, variation in PIR sensitivity, animal behavior, and species-specific infrared radiation. Population surveys using trail cameras with PIR systems must incorporate detection rates for individual cameras. Incorporating time-lapse triggering systems into survey designs should eliminate issues associated with PIR systems.

  5. Laser based analysis using a passively Q-switched laser employing analysis electronics and a means for detecting atomic optical emission of the laser media

    DOEpatents

    Woodruff, Steven D.; Mcintyre, Dustin L.

    2016-03-29

    A device for Laser based Analysis using a Passively Q-Switched Laser comprising an optical pumping source optically connected to a laser media. The laser media and a Q-switch are positioned between and optically connected to a high reflectivity mirror (HR) and an output coupler (OC) along an optical axis. The output coupler (OC) is optically connected to the output lens along the optical axis. A means for detecting atomic optical emission comprises a filter and a light detector. The optical filter is optically connected to the laser media and the optical detector. A control system is connected to the optical detector and the analysis electronics. The analysis electronics are optically connected to the output lens. The detection of the large scale laser output production triggers the control system to initiate the precise timing and data collection from the detector and analysis.

  6. Suppression of optical beat interference-noise in orthogonal frequency division multiple access-passive optical network link using self-homodyne balanced detection

    NASA Astrophysics Data System (ADS)

    Won, Yong-Yuk; Jung, Sang-Min; Han, Sang-Kook

    2014-08-01

    A new technique, which reduces optical beat interference (OBI) noise in orthogonal frequency division multiple access-passive optical network (OFDMA-PON) links, is proposed. A self-homodyne balanced detection, which uses a single laser for the optical line terminal (OLT) as well as for the optical network unit (ONU), reduces OBI noise and also improves the signal to noise ratio (SNR) of the discrete multi-tone (DMT) signal. The proposed scheme is verified by transmitting quadrature phase shift keying (QPSK)-modulated DMT signal over a 20-km single mode fiber. The optical signal to noise ratio (OSNR), that is required for BER of 10-5, is reduced by 2 dB in the balanced detection compared with a single channel due to the cancellation of OBI noise in conjunction with the local laser.

  7. Remarkable sensitivity for detection of bisphenol A on a gold electrode modified with nickel tetraamino phthalocyanine containing Ni-O-Ni bridges.

    PubMed

    Chauke, Vongani; Matemadombo, Fungisai; Nyokong, Tebello

    2010-06-15

    This work reports the electrocatalysis of bisphenol A on Ni(II) tetraamino metallophthalocyanine (NiTAPc) polymer modified gold electrode containing Ni-O-Ni bridges (represented as Ni(OH)TAPc). The Ni(II)TAPc films were electro-transformed in 0.1 mol L(-1) NaOH aqueous solution to form 'O-Ni-O oxo bridges', forming poly-n-Ni(OH)TAPc (where n is the number of polymerising scans). poly-30-Ni(OH)TAPc, poly-50-Ni(OH)TAPc, poly-70-Ni(OH)TAPc and poly-90-Ni(OH)TAPc films were investigated. The polymeric films were characterised by electrochemical impedance spectroscopy and the charge transfer resistance (R(CT)) values increased with film thickness. The best catalytic activity for the detection of bisphenol A was on poly-70-Ni(OH)TAPc. Electrode resistance to passivation improved with polymer thickness. The electrocatalytic behaviour of bisphenol A was compared to that of p-nitrophenol in terms of electrode passivation and regeneration. The latter was found to passivate the electrode less than the former. The poly-70-Ni(OH)TAPc modified electrode could reliably detect bisphenol A in a concentration range of 7x10(-4) to 3x10(-2)mol L(-1) with a limit of detection of 3.68x10(-9)mol L(-1). The sensitivity was 3.26x10(-4)A mol(-1) L cm(-2). Copyright 2010 Elsevier B.V. All rights reserved.

  8. Electrical Characterization of Amorphous Silicon MIS-Based Structures for HIT Solar Cell Applications.

    PubMed

    García, Héctor; Castán, Helena; Dueñas, Salvador; Bailón, Luis; García-Hernansanz, Rodrigo; Olea, Javier; Del Prado, Álvaro; Mártil, Ignacio

    2016-12-01

    A complete electrical characterization of hydrogenated amorphous silicon layers (a-Si:H) deposited on crystalline silicon (c-Si) substrates by electron cyclotron resonance chemical vapor deposition (ECR-CVD) was carried out. These structures are of interest for photovoltaic applications. Different growth temperatures between 30 and 200 °C were used. A rapid thermal annealing in forming gas atmosphere at 200 °C during 10 min was applied after the metallization process. The evolution of interfacial state density with the deposition temperature indicates a better interface passivation at higher growth temperatures. However, in these cases, an important contribution of slow states is detected as well. Thus, using intermediate growth temperatures (100-150 °C) might be the best choice.

  9. Electrical Characterization of Amorphous Silicon MIS-Based Structures for HIT Solar Cell Applications

    NASA Astrophysics Data System (ADS)

    García, Héctor; Castán, Helena; Dueñas, Salvador; Bailón, Luis; García-Hernansanz, Rodrigo; Olea, Javier; del Prado, Álvaro; Mártil, Ignacio

    2016-07-01

    A complete electrical characterization of hydrogenated amorphous silicon layers (a-Si:H) deposited on crystalline silicon (c-Si) substrates by electron cyclotron resonance chemical vapor deposition (ECR-CVD) was carried out. These structures are of interest for photovoltaic applications. Different growth temperatures between 30 and 200 °C were used. A rapid thermal annealing in forming gas atmosphere at 200 °C during 10 min was applied after the metallization process. The evolution of interfacial state density with the deposition temperature indicates a better interface passivation at higher growth temperatures. However, in these cases, an important contribution of slow states is detected as well. Thus, using intermediate growth temperatures (100-150 °C) might be the best choice.

  10. Design of an infrared camera based aircraft detection system for laser guide star installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman, H.; Macintosh, B.

    1996-03-05

    There have been incidents in which the irradiance resulting from laser guide stars have temporarily blinded pilots or passengers of aircraft. An aircraft detection system based on passive near infrared cameras (instead of active radar) is described in this report.

  11. Reduction in symptomatic malaria prevalence through proactive community treatment in rural Senegal.

    PubMed

    Linn, Annē M; Ndiaye, Youssoupha; Hennessee, Ian; Gaye, Seynabou; Linn, Patrick; Nordstrom, Karin; McLaughlin, Matt

    2015-11-01

    We piloted a community-based proactive malaria case detection model in rural Senegal to evaluate whether this model can increase testing and treatment and reduce prevalence of symptomatic malaria in target communities. Home care providers conducted weekly sweeps of every household in their village throughout the transmission season to identify patients with symptoms of malaria, perform rapid diagnostic tests (RDT) on symptomatic patients and provide treatment for positive cases. The model was implemented in 15 villages from July to November 2013, the high transmission season. Fifteen comparison villages were chosen from those implementing Senegal's original, passive model of community case management of malaria. Three sweeps were conducted in the comparison villages to compare prevalence of symptomatic malaria using difference in differences analysis. At baseline, prevalence of symptomatic malaria confirmed by RDT for all symptomatic individuals found during sweeps was similar in both sets of villages (P = 0.79). At end line, prevalence was 16 times higher in the comparison villages than in the intervention villages (P = 0.003). Adjusting for potential confounders, the intervention was associated with a 30-fold reduction in odds of symptomatic malaria in the intervention villages (AOR = 0.033; 95% CI: 0.017, 0.065). Treatment seeking also increased in the intervention villages, with 57% of consultations by home care providers conducted between sweeps through routine community case management. This pilot study suggests that community-based proactive case detection reduces symptomatic malaria prevalence, likely through more timely case management and improved care seeking behaviour. A randomised controlled trial is needed to further evaluate the impact of this model. © 2015 John Wiley & Sons Ltd.

  12. RFI Detection and Mitigation using Independent Component Analysis as a Pre-Processor

    NASA Technical Reports Server (NTRS)

    Schoenwald, Adam J.; Gholian, Armen; Bradley, Damon C.; Wong, Mark; Mohammed, Priscilla N.; Piepmeier, Jeffrey R.

    2016-01-01

    Radio-frequency interference (RFI) has negatively impacted scientific measurements of passive remote sensing satellites. This has been observed in the L-band radiometers Soil Moisture and Ocean Salinity (SMOS), Aquarius and more recently, Soil Moisture Active Passive (SMAP). RFI has also been observed at higher frequencies such as K band. Improvements in technology have allowed wider bandwidth digital back ends for passive microwave radiometry. A complex signal kurtosis radio frequency interference detector was developed to help identify corrupted measurements. This work explores the use of Independent Component Analysis (ICA) as a blind source separation (BSS) technique to pre-process radiometric signals for use with the previously developed real and complex signal kurtosis detectors.

  13. An equivalent method of mixed dielectric constant in passive microwave/millimeter radiometric measurement

    NASA Astrophysics Data System (ADS)

    Su, Jinlong; Tian, Yan; Hu, Fei; Gui, Liangqi; Cheng, Yayun; Peng, Xiaohui

    2017-10-01

    Dielectric constant is an important role to describe the properties of matter. This paper proposes This paper proposes the concept of mixed dielectric constant(MDC) in passive microwave radiometric measurement. In addition, a MDC inversion method is come up, Ratio of Angle-Polarization Difference(RAPD) is utilized in this method. The MDC of several materials are investigated using RAPD. Brightness temperatures(TBs) which calculated by MDC and original dielectric constant are compared. Random errors are added to the simulation to test the robustness of the algorithm. Keywords: Passive detection, microwave/millimeter, radiometric measurement, ratio of angle-polarization difference (RAPD), mixed dielectric constant (MDC), brightness temperatures, remote sensing, target recognition.

  14. Is the Venice Lagoon Noisy? First Passive Listening Monitoring of the Venice Lagoon: Possible Effects on the Typical Fish Community.

    PubMed

    Bolgan, Marta; Picciulin, Marta; Codarin, Antonio; Fiorin, Riccardo; Zucchetta, Matteo; Malavasi, Stefano

    2016-01-01

    Three passive listening surveys have been carried out in two of the three Venice lagoon tide inlets and inside the Venice island. The spectral content and the intensity level of the underwater noise as well as the presence or absence of Sciaena umbra and the distribution of its different sound patterns have been investigated in all the recording sites. The passive listening proved to be successful in detecting S. umbra drumming sounds in both Venice lagoon tide inlets. Our results indicate that the spectral content and the level of underwater noise pollution in the Venice lagoon could affect fish acoustic communication.

  15. Examining the Effectiveness of Hacked, Commercial, Self-Tuning RFID Tags to Passively Sense the Volumetric Water Content of Soil

    NASA Astrophysics Data System (ADS)

    Stoddard, B. S.; Udell, C.; Selker, J. S.

    2017-12-01

    Currently available soil volumetric water content (VWC) sensors have several drawbacks that pose certain challenges for implementation on large scale for farms. Such issues include cost, scalability, maintenance, wires running through fields, and single-spot resolution. The development of a passive soil moisture sensing system utilizing Radio Frequency Identification (RFID) would allay many of these issues. The type of passive RFID tags discussed in this paper currently cost between 8 to 15 cents retail per tag when purchased in bulk. An incredibly cheap, scalable, low-maintenance, wireless, high-resolution system for sensing soil moisture would be possible if such tags were introduced into the agricultural world. This paper discusses both the use cases as well as examines one implementation of the tags. In 2015, RFID tag manufacturer SmarTrac started selling RFID moisture sensing tags for use in the automotive industry to detect leaks during quality assurance. We place those tags in soil at a depth of 4 inches and compared the moisture levels sensed by the RFID tags with the relative permittivity (ɛr) of the soil as measured by an industry-standard probe. Using an equation derived by Topp et al, we converted to VWC. We tested this over a wide range of moisture conditions and found a statistically significant, correlational relationship between the sensor values from the RFID tags and the probe's measurement of ɛr. We also identified a possible function for mapping vales from the RFID tag to the probe bounded by a reasonable margin of error.

  16. Measurement of indoor formaldehyde concentrations with a passive sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gillett, R.W.; Kreibich, H.; Ayers, G.P.

    2000-05-15

    An existing Ferm-type passive sampler technique has been further developed to measure concentrations of formaldehyde gas in indoor air. Formaldehyde forms a derivative after reaction with a filter coated with 2,4-dinitrophenylhydrazine (2,4-DNPH). The formaldehyde 2,4-dinitrophenylhydrazine derivative (formaldehyde-2,4-DNPH) is extracted from the filter, and the concentration is determined by high-performance liquid chromatography. The technique has been validated against an active sampling method, and the agreement is close when the appropriate laminar boundary layer depth is applied to the passive measurement. For this technique an exposure period of 3 days is equivalent to a limit of detection of formaldehyde of 3.4 ppbvmore » and a limit of quantification of 7.6 ppbv. To test the performance of the passive samplers ambient formaldehyde measurements were carried out inside homes and in a range of workplace environments.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kephart, Jason M.; Kindvall, Anna; Williams, Desiree

    Commercial CdTe PV modules have polycrystalline thin films deposited on glass, and devices made in this format have exceeded 22% efficiency. Devices made by the authors with a magnesium zinc oxide window layer and tellurium back contact have achieved efficiency over 18%, but these cells still suffer from an open-circuit voltage far below ideal values. Oxide passivation layers made by sputter deposition have the potential to increase voltage by reducing interface recombination. CdTe devices with these passivation layers were studied with photoluminescence (PL) emission spectroscopy and time-resolved photoluminescence (TRPL) to detect an increase in minority carrier lifetime. Because these oxidemore » materials exhibit barriers to carrier collection, micropatterning was used to expose small point contacts while still allowing interface passivation. TRPL decay lifetimes have been greatly enhanced for thin polycrystalline absorber films with interface passivation. Device performance was measured and current collection was mapped spatially by light-beam-induced current.« less

  18. A promising microbiological test for the diagnosis of drowning.

    PubMed

    Lucci, Arturo; Campobasso, Carlo P; Cirnelli, Antonello; Lorenzini, Giulio

    2008-11-20

    A number of biological and chemical tests have been developed over the years to determine whether a person was drowned. This study focuses on the potential of a microbiological test for detecting common bacterial markers of water faecal pollution such as faecal coliforms (FC) and faecal streptococci (FS) as possible indicators of drowning. A promising previous study was carried out on central and peripheral blood samples of 42 drowned victims (20 cases in saltwater and 22 cases in freshwater) and 30 not-drowned bodies. To improve the accuracy of our previous results and also in order to investigate a possible cause of a false positive due to pulmonary passive diffusion and subsequently endogenous or exogenous bacterial invasion of the blood in the post-mortem interval (PMI), the FC and FS test was applied to bodies submerged in water but died from causes other than drowning. In the present study, blood samples collected from the left ventricle (LV), right ventricle (RV), femoral artery (FA) and, femoral vein (FV) of 10 drowned victims (5 cases in freshwater and 5 cases in seawater) and 3 not-drowned individuals with bodies submerged in water for a while after death have been analysed. Preliminary results are in agreement with other reports dealing with diatoms and marine bacteria that suggest to exclude the hypothesis of a passive penetration of sufficient quantities of drowning medium into circulation after death or during the agonal period. Based on our results there is also no evidence of a relevant dissemination of endogenous micro-flora from the gastrointestinal tract affecting the FS and FC test. There are still several other factors that could influence the applicability of post-mortem FS and FC cultures for the diagnosis of drowning and they need further investigations. The present article provides only a glimpse of the potential of the FS and FC test as bacteriological method for the diagnosis of drowning.

  19. Marine Mammals and Active Sonar

    DTIC Science & Technology

    2005-10-01

    Stafford , K. M., C. G. Fox, and D. S. Clark. 1998 . Long - range acoustic detection , localization of blue whale calls in the northeast...signal processing generated by other projects. The current effort on detection , classification, and localization of northern right whales as well as a...causal mechanisms of sonar-related beaked whale strandings. ONR is funding various research projects including passive acoustic detection

  20. Gravel addition as a habitat restoration technique for tailwaters

    Treesearch

    Ryan McManamay; D. Orth; Charles Dolloff; Mark Cantrell

    2010-01-01

    We assessed the efficacy of passive gravel addition at forming catostomid spawning habitat under various flow regimes in the Cheoah River, a high-gradient tailwater river in North Carolina. The purpose was to provide a case study that included recommendations for future applications. A total of 76.3 m3 (162 tons) of washed gravel (10-50 mm) was passively dumped down...

  1. Passive monitoring using traffic noise recordings - case study on the Steinachtal Bridge

    NASA Astrophysics Data System (ADS)

    Salvermoser, Johannes; Stähler, Simon; Hadziioannou, Céline

    2015-04-01

    Civil structures age continuously. The early recognition of potentially critical damages is an important economical issue, but also one of public safety. Continuous tracking of small changes in the medium by using passive methods would offer an extension to established active non-destructive testing procedures at relatively low cost. Here we present a case study of structural monitoring using continuous recordings of traffic noise on a 200 meter long reinforced concrete highway bridge in Germany. Over two months of continuos geophone records are used in the frequency range of 2-8 Hz. Using passive image interferometry, evaluation of hourly cross-correlations between recordings at pairs of receivers yield velocity variations in the range of -1.5% to +2.1%. We were able to correlate our outcomes with temperature measurements of the same two month period. The measured velocity changes scale with the temperature variations with on average a dv/v of 0.064% per degree Celsius. This value is in accordance with other studies of concrete response to temperature, confirming that we are able to observe subtle changes with physical origin. It is shown that traffic noise is temporally homogenenous enough to fulfill the requirements of passive image interferometry.

  2. Improving Toxicity Assessment of Pesticide Mixtures: The Use of Polar Passive Sampling Devices Extracts in Microalgae Toxicity Tests

    PubMed Central

    Kim Tiam, Sandra; Fauvelle, Vincent; Morin, Soizic; Mazzella, Nicolas

    2016-01-01

    Complexity of contaminants exposure needs to be taking in account for an appropriate evaluation of risks related to mixtures of pesticides released in the ecosystems. Toxicity assessment of such mixtures can be made through a variety of toxicity tests reflecting different level of biological complexity. This paper reviews the recent developments of passive sampling techniques for polar compounds, especially Polar Organic Chemical Integrative Samplers (POCIS) and Chemcatcher® and the principal assessment techniques using microalgae in laboratory experiments. The progresses permitted by the coupled use of such passive samplers and ecotoxicology testing as well as their limitations are presented. Case studies combining passive sampling devices (PSD) extracts and toxicity assessment toward microorganisms at different biological scales from single organisms to communities level are presented. These case studies, respectively, aimed (i) at characterizing the “toxic potential” of waters using dose-response curves, and (ii) at performing microcosm experiments with increased environmental realism in the toxicant exposure in term of cocktail composition and concentration. Finally perspectives and limitations of such approaches for future applications in the area of environmental risk assessment are discussed. PMID:27667986

  3. Gas-cell measurements for evaluating longwave-infrared passive-sensor performance

    NASA Astrophysics Data System (ADS)

    Cummings, Alan S.; Combs, Roger J.; Thomas, Mark J.; Curry, Timothy; Kroutil, Robert T.

    2006-10-01

    A longwave-infrared (LWIR) passive-spectrometer performance was evaluated with a short-pathlength gas cell. This cell was accurately positioned between the sensor and a NIST-traceable blackbody radiance source. Cell contents were varied over the Beer's Law absorbance range from the limit of detection to saturation for the gas analytes of sulfur hexafluoride and hexafluoroethane. The spectral impact of saturation on infrared absorbance was demonstrated for the passive sensor configuration. The gas-cell contents for all concentration-pathlength products was monitored with an active traditional-laboratory Fourier Transform Infrared (FTIR) spectrometer and was verified by comparison with the established PNNL/DOE vapor-phase infrared (IR) spectral database. For the passive FTIR measurements, the blackbody source employed a range of background temperatures from 5 °C to 50 °C. The passive measurements without the presence of a gas cell permitted a determination of the noise equivalent spectral noise (NESR) for each set of passive gas-cell measurements. In addition, the no-cell condition allowed the evaluation of the effect of gas cell window materials of low density poly(ethylene), potassium chloride, potassium bromide, and zinc selenide. The components of gas cell, different window materials, temperature differentials, and absorbances of target-analyte gases supplied the means of evaluating the LWIR performance of a passive FTIR spectrometer. The various LWIR-passive measurements were found to simulate those often encountered in open-air scenarios important to both industrial and environmental monitoring applications.

  4. Malaria is associated with poor school performance in an endemic area of the Brazilian Amazon

    PubMed Central

    Vitor-Silva, Sheila; Reyes-Lecca, Roberto C; Pinheiro, Tamam RA; Lacerda, Marcus VG

    2009-01-01

    Background Approximately 40% of the world's population is at risk for malaria. In highly endemic tropical areas, malaria is a major cause of morbidity and mortality during infancy. There is a complex interrelationship between malaria, malnutrition and intestinal helminths, and this may impair cognitive development in children. The aim of this study was to determine the relationship between malaria and school performance in children living in an endemic area where Plasmodium vivax is the species responsible for most of the cases. Methods The study was conducted in the Municipality of Careiro, Amazonas, Brazil, with five to14 year-old children, studying the first eight grades of public school, during the year 2008. After an initial active case detection, during nine months of follow-up, passive malaria cases detection was instituted, through a thick blood smear performed in every child with fever. School performance was evaluated by the final notes in Mathematics and Portuguese Language. Performance was considered poor when either of the final notes in these disciplines was below the 50th percentile for the respective class and grade. Results The total number of students followed-up in the cohort was 198. Malarial attacks were reported in 70 (35.4%) of these students, with no cases of severe disease. Plasmodium vivax was detected in 69.2% of the attacks, Plasmodium falciparum in 25.5% and both species in 5.3%. In the multivariate analysis, adjusting for age, mother's education, time living in the study area and school absenteeism, presenting with at least one episode of malaria independently predicted a poor performance at school [OR = 1.91 (1.04-3.54); p = 0.039]. Conclusion Non-severe malaria compromises the school performance of children even during a nine-month follow-up, potentially contributing to the maintenance of underdevelopment in countries endemic for malaria. This is the first evidence of such impact in Latin America, where P. vivax is responsible for the majority of the cases. PMID:19835584

  5. Syndromic Algorithms for Detection of Gambiense Human African Trypanosomiasis in South Sudan

    PubMed Central

    Palmer, Jennifer J.; Surur, Elizeous I.; Goch, Garang W.; Mayen, Mangar A.; Lindner, Andreas K.; Pittet, Anne; Kasparian, Serena; Checchi, Francesco; Whitty, Christopher J. M.

    2013-01-01

    Background Active screening by mobile teams is considered the best method for detecting human African trypanosomiasis (HAT) caused by Trypanosoma brucei gambiense but the current funding context in many post-conflict countries limits this approach. As an alternative, non-specialist health care workers (HCWs) in peripheral health facilities could be trained to identify potential cases who need testing based on their symptoms. We explored the predictive value of syndromic referral algorithms to identify symptomatic cases of HAT among a treatment-seeking population in Nimule, South Sudan. Methodology/Principal Findings Symptom data from 462 patients (27 cases) presenting for a HAT test via passive screening over a 7 month period were collected to construct and evaluate over 14,000 four item syndromic algorithms considered simple enough to be used by peripheral HCWs. For comparison, algorithms developed in other settings were also tested on our data, and a panel of expert HAT clinicians were asked to make referral decisions based on the symptom dataset. The best performing algorithms consisted of three core symptoms (sleep problems, neurological problems and weight loss), with or without a history of oedema, cervical adenopathy or proximity to livestock. They had a sensitivity of 88.9–92.6%, a negative predictive value of up to 98.8% and a positive predictive value in this context of 8.4–8.7%. In terms of sensitivity, these out-performed more complex algorithms identified in other studies, as well as the expert panel. The best-performing algorithm is predicted to identify about 9/10 treatment-seeking HAT cases, though only 1/10 patients referred would test positive. Conclusions/Significance In the absence of regular active screening, improving referrals of HAT patients through other means is essential. Systematic use of syndromic algorithms by peripheral HCWs has the potential to increase case detection and would increase their participation in HAT programmes. The algorithms proposed here, though promising, should be validated elsewhere. PMID:23350005

  6. Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging

    PubMed Central

    Haworth, Kevin J.; Raymond, Jason L.; Radhakrishnan, Kirthi; Moody, Melanie R.; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E.; Kim, Hyunggun; Mcpherson, David D.; Holland, Christy K.

    2015-01-01

    Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. PMID:26547633

  7. A Methodological Framework to Estimate the Site Fidelity of Tagged Animals Using Passive Acoustic Telemetry

    PubMed Central

    Capello, Manuela; Robert, Marianne; Soria, Marc; Potin, Gael; Itano, David; Holland, Kim; Deneubourg, Jean-Louis; Dagorn, Laurent

    2015-01-01

    The rapid expansion of the use of passive acoustic telemetry technologies has facilitated unprecedented opportunities for studying the behavior of marine organisms in their natural environment. This technological advance would greatly benefit from the parallel development of dedicated methodologies accounting for the variety of timescales involved in the remote detection of tagged animals related to instrumental, environmental and behavioral events. In this paper we propose a methodological framework for estimating the site fidelity (“residence times”) of acoustic tagged animals at different timescales, based on the survival analysis of continuous residence times recorded at multiple receivers. Our approach is validated through modeling and applied on two distinct datasets obtained from a small coastal pelagic species (bigeye scad, Selar crumenophthalmus) and a large, offshore pelagic species (yellowfin tuna, Thunnus albacares), which show very distinct spatial scales of behavior. The methodological framework proposed herein allows estimating the most appropriate temporal scale for processing passive acoustic telemetry data depending on the scientific question of interest. Our method provides residence times free of the bias inherent to environmental and instrumental noise that can be used to study the small scale behavior of acoustic tagged animals. At larger timescales, it can effectively identify residence times that encompass the diel behavioral excursions of fish out of the acoustic detection range. This study provides a systematic framework for the analysis of passive acoustic telemetry data that can be employed for the comparative study of different species and study sites. The same methodology can be used each time discrete records of animal detections of any nature are employed for estimating the site fidelity of an animal at different timescales. PMID:26261985

  8. A Methodological Framework to Estimate the Site Fidelity of Tagged Animals Using Passive Acoustic Telemetry.

    PubMed

    Capello, Manuela; Robert, Marianne; Soria, Marc; Potin, Gael; Itano, David; Holland, Kim; Deneubourg, Jean-Louis; Dagorn, Laurent

    2015-01-01

    The rapid expansion of the use of passive acoustic telemetry technologies has facilitated unprecedented opportunities for studying the behavior of marine organisms in their natural environment. This technological advance would greatly benefit from the parallel development of dedicated methodologies accounting for the variety of timescales involved in the remote detection of tagged animals related to instrumental, environmental and behavioral events. In this paper we propose a methodological framework for estimating the site fidelity ("residence times") of acoustic tagged animals at different timescales, based on the survival analysis of continuous residence times recorded at multiple receivers. Our approach is validated through modeling and applied on two distinct datasets obtained from a small coastal pelagic species (bigeye scad, Selar crumenophthalmus) and a large, offshore pelagic species (yellowfin tuna, Thunnus albacares), which show very distinct spatial scales of behavior. The methodological framework proposed herein allows estimating the most appropriate temporal scale for processing passive acoustic telemetry data depending on the scientific question of interest. Our method provides residence times free of the bias inherent to environmental and instrumental noise that can be used to study the small scale behavior of acoustic tagged animals. At larger timescales, it can effectively identify residence times that encompass the diel behavioral excursions of fish out of the acoustic detection range. This study provides a systematic framework for the analysis of passive acoustic telemetry data that can be employed for the comparative study of different species and study sites. The same methodology can be used each time discrete records of animal detections of any nature are employed for estimating the site fidelity of an animal at different timescales.

  9. The spatial distribution of the reactive iodine species IO from simultaneous active and passive DOAS observations

    NASA Astrophysics Data System (ADS)

    Seitz, K.; Buxmann, J.; Pöhler, D.; Sommer, T.; Tschritter, J.; Neary, T.; O'Dowd, C.; Platt, U.

    2010-03-01

    We present investigations of the reactive iodine species (RIS) IO, OIO and I2 in a coastal region from a field campaign simultaneously employing active long path differential optical absorption spectroscopy (LP-DOAS) as well as passive multi-axis differential optical absorption spectroscopy (MAX-DOAS). The campaign took place at the Martin Ryan Institute (MRI) in Carna, County Galway at the Irish West Coast about 6 km south-east of the atmospheric research station Mace Head in summer 2007. In order to study the horizontal distribution of the trace gases of interest, we established two almost parallel active LP-DOAS light paths, the shorter of 1034 m length just crossing the intertidal area, whereas the longer one of 3946 m length also crossed open water during periods of low tide. In addition we operated two passive Mini-MAX-DOAS instruments with the same viewing direction. While neither OIO nor I2 could be unambiguously identified with any of the instruments, IO could be detected with active as well as passive DOAS. The IO column densities seen at both active LP-DOAS light paths are almost the same. Thus it can be concluded that coastal IO is almost exclusively located in the intertidal area, where we detected mixing ratios of up to 29±8.8 ppt (equivalent to pmol/mol). Nucleation events with particle concentrations of 106 cm-3 particles were observed each day correlating with high IO mixing ratios. Therefore we feel that our detected IO concentrations confirm the results of model studies, which state that in order to explain such particle bursts, IO mixing ratios of 50 to 100 ppt in so called "hot-spots" are required.

  10. The spatial distribution of the reactive iodine species IO from simultaneous active and passive DOAS observations

    NASA Astrophysics Data System (ADS)

    Seitz, K.; Buxmann, J.; Pöhler, D.; Sommer, T.; Tschritter, J.; O'Dowd, C.; Platt, U.

    2009-10-01

    We present investigations of the reactive iodine species (RIS) IO, OIO and I2 in a coastal region from a field campaign simultaneously employing active long path differential optical absorption spectroscopy (LP-DOAS) as well as passive multi-axis differential optical absorption spectroscopy (MAX-DOAS). The campaign took place at the Martin Ryan Institute (MRI) in Carna, County Galway at the Irish West Coast about 6 km south-east of the atmospheric research station Mace Head in summer 2007. In order to study the horizontal distribution of the trace gases of interest, we established two almost parallel active LP-DOAS light paths, the shorter of 1034 m length just crossing the intertidal area, whereas the longer one of 3946 m length also crossed open water during periods of low tide. In addition we operated two passive Mini-MAX-DOAS instruments with the same viewing direction. While neither OIO nor I2 could be unambiguously identified with any of the instruments, IO could be detected with active as well as passive DOAS. The IO column densities seen at both active LP-DOAS light paths are almost the same. Thus it can be concluded that coastal IO is almost exclusively located in the intertidal area, where we detected mixing ratios of up to 35±7.7 ppt (equivalent to pmol/mol). Nucleation events with particle concentrations of 106 cm-3 particles were observed each day correlating with high IO mixing ratios. Therefore we feel that our detected IO concentrations confirm the results of model studies, which state that in order to explain such particle bursts, IO mixing ratios of 50 to 100 ppt in so called "hot-spots" are required.

  11. Single Photon Counting UV Solar-Blind Detectors Using Silicon and III-Nitride Materials

    PubMed Central

    Nikzad, Shouleh; Hoenk, Michael; Jewell, April D.; Hennessy, John J.; Carver, Alexander G.; Jones, Todd J.; Goodsall, Timothy M.; Hamden, Erika T.; Suvarna, Puneet; Bulmer, J.; Shahedipour-Sandvik, F.; Charbon, Edoardo; Padmanabhan, Preethi; Hancock, Bruce; Bell, L. Douglas

    2016-01-01

    Ultraviolet (UV) studies in astronomy, cosmology, planetary studies, biological and medical applications often require precision detection of faint objects and in many cases require photon-counting detection. We present an overview of two approaches for achieving photon counting in the UV. The first approach involves UV enhancement of photon-counting silicon detectors, including electron multiplying charge-coupled devices and avalanche photodiodes. The approach used here employs molecular beam epitaxy for delta doping and superlattice doping for surface passivation and high UV quantum efficiency. Additional UV enhancements include antireflection (AR) and solar-blind UV bandpass coatings prepared by atomic layer deposition. Quantum efficiency (QE) measurements show QE > 50% in the 100–300 nm range for detectors with simple AR coatings, and QE ≅ 80% at ~206 nm has been shown when more complex AR coatings are used. The second approach is based on avalanche photodiodes in III-nitride materials with high QE and intrinsic solar blindness. PMID:27338399

  12. Single Photon Counting UV Solar-Blind Detectors Using Silicon and III-Nitride Materials.

    PubMed

    Nikzad, Shouleh; Hoenk, Michael; Jewell, April D; Hennessy, John J; Carver, Alexander G; Jones, Todd J; Goodsall, Timothy M; Hamden, Erika T; Suvarna, Puneet; Bulmer, J; Shahedipour-Sandvik, F; Charbon, Edoardo; Padmanabhan, Preethi; Hancock, Bruce; Bell, L Douglas

    2016-06-21

    Ultraviolet (UV) studies in astronomy, cosmology, planetary studies, biological and medical applications often require precision detection of faint objects and in many cases require photon-counting detection. We present an overview of two approaches for achieving photon counting in the UV. The first approach involves UV enhancement of photon-counting silicon detectors, including electron multiplying charge-coupled devices and avalanche photodiodes. The approach used here employs molecular beam epitaxy for delta doping and superlattice doping for surface passivation and high UV quantum efficiency. Additional UV enhancements include antireflection (AR) and solar-blind UV bandpass coatings prepared by atomic layer deposition. Quantum efficiency (QE) measurements show QE > 50% in the 100-300 nm range for detectors with simple AR coatings, and QE ≅ 80% at ~206 nm has been shown when more complex AR coatings are used. The second approach is based on avalanche photodiodes in III-nitride materials with high QE and intrinsic solar blindness.

  13. Preliminary Investigation of Trypanosomosis in Exotic Dog Breeds from Zambia's Luangwa and Zambezi Valleys Using LAMP

    PubMed Central

    Namangala, Boniface; Oparaocha, Elizabeth; Kajino, Kiichi; Hayashida, Kyoko; Moonga, Ladslav; Inoue, Noboru; Suzuki, Yasuhiko; Sugimoto, Chihiro

    2013-01-01

    Canine African trypanosomosis (CAT) is rarely reported in the literature. In this preliminary study, we evaluated the performance of loop-mediated isothermal amplification (LAMP) against microscopy to detect CAT in six exotic dog breeds naturally infected with trypanosomes from Zambia's South Luangwa National Park and Chiawa Game Management Area. To our knowledge, this is the first report of CAT in Zambia. The patients exhibited a variety of aspecific clinical signs. The LAMP did not only confirm all six parasitologically positive CAT cases detected passively between April 2010 and January 2012, but was also critical in trypanosome speciation. According to LAMP, the majority of the dogs had monolytic infections with either Trypanosoma congolense or Trypanosoma brucei rhodesiense. The LAMP is thus a potential simple and cost-effective tool for trypanosome diagnosis in endemic regions. The rare report of zoonotic trypanosomes in dogs in Zambia has public health implications and justifies further investigations of CAT. PMID:23716412

  14. Building America Case Study: Design Guidance for Passive Vents in New Construction Multifamily Buildings, New York, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2016-02-01

    This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated sourcemore » of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.« less

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thi, Trinh Cham, E-mail: s1240009@jaist.ac.jp; Koyama, Koichi; Ohdaira, Keisuke

    We improve the passivation property of n-type crystalline silicon (c-Si) surface passivated with a catalytic chemical vapor deposited (Cat-CVD) Si nitride (SiN{sub x}) film by inserting a phosphorous (P)-doped layer formed by exposing c-Si surface to P radicals generated by the catalytic cracking of PH{sub 3} molecules (Cat-doping). An extremely low surface recombination velocity (SRV) of 2 cm/s can be achieved for 2.5 Ω cm n-type (100) floating-zone Si wafers passivated with SiN{sub x}/P Cat-doped layers, both prepared in Cat-CVD systems. Compared with the case of only SiN{sub x} passivated layers, SRV decreases from 5 cm/s to 2 cm/s. The decrease in SRVmore » is the result of field effect created by activated P atoms (donors) in a shallow P Cat-doped layer. Annealing process plays an important role in improving the passivation quality of SiN{sub x} films. The outstanding results obtained imply that SiN{sub x}/P Cat-doped layers can be used as promising passivation layers in high-efficiency n-type c-Si solar cells.« less

  16. Building-level analyses to prospectively detect influenza outbreaks in long-term care facilities: New York City, 2013-2014.

    PubMed

    Levin-Rector, Alison; Nivin, Beth; Yeung, Alice; Fine, Annie D; Greene, Sharon K

    2015-08-01

    Timely outbreak detection is necessary to successfully control influenza in long-term care facilities (LTCFs) and other institutions. To supplement nosocomial outbreak reports, calls from infection control staff, and active laboratory surveillance, the New York City (NYC) Department of Health and Mental Hygiene implemented an automated building-level analysis to proactively identify LTCFs with laboratory-confirmed influenza activity. Geocoded addresses of LTCFs in NYC were compared with geocoded residential addresses for all case-patients with laboratory-confirmed influenza reported through passive surveillance. An automated daily analysis used the geocoded building identification number, approximate text matching, and key-word searches to identify influenza in residents of LTCFs for review and follow-up by surveillance coordinators. Our aim was to determine whether the building analysis improved prospective outbreak detection during the 2013-2014 influenza season. Of 119 outbreaks identified in LTCFs, 109 (92%) were ever detected by the building analysis, and 55 (46%) were first detected by the building analysis. Of the 5,953 LTCF staff and residents who received antiviral prophylaxis during the 2013-2014 season, 929 (16%) were at LTCFs where outbreaks were initially detected by the building analysis. A novel building-level analysis improved influenza outbreak identification in LTCFs in NYC, prompting timely infection control measures. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. Soil Moisture Active Passive (SMAP) Microwave Radiometer Radio-Frequency Interference (RFI) Mitigation: Initial On-Orbit Results

    NASA Technical Reports Server (NTRS)

    Mohammed, Priscilla N.; Piepmeier, Jeffrey R.; Johnson, Joel T.; Aksoy, Mustafa; Bringer, Alexandra

    2015-01-01

    The Soil Moisture Active Passive (SMAP) mission, launched in January 2015, provides global measurements of soil moisture using a microwave radiometer. SMAPs radiometer passband lies within the passive frequency allocation. However, both unauthorized in-band transmitters as well as out-of-band emissions from transmitters operating at frequencies adjacent to this allocated spectrum have been documented as sources of radio frequency interference (RFI) to the L-band radiometers on SMOS and Aquarius. The spectral environment consists of high RFI levels as well as significant occurrences of low level RFI equivalent to 0.1 to 10 K. The SMAP ground processor reports the antenna temperature both before and after RFI mitigation is applied. The difference between these quantities represents the detected RFI level. The presentation will review the SMAP RFI detection and mitigation procedure and discuss early on-orbit RFI measurements from the SMAP radiometer. Assessments of global RFI properties and source types will be provided, as well as the implications of these results for SMAP soil moisture measurements.

  18. Passive bistatic radar analysis

    NASA Astrophysics Data System (ADS)

    O'Hagan, Daniel W.; Kuschel, H.; Schiller, Joachim

    2009-06-01

    Passive Bistatic Radar (PBR) research is at its zenith with several notable PBR systems currently operational, or available for deployment. Such PBRs include the Manastash Ridge Radar (MRR) developed for and by academia; Silent Sentry developed as a commercial concern by Lockheed Martin; and Homeland Alerter (HA100) also a commercial system developed by Thales. However at present, despite the existence of numerous PBR prototypes, take up of commercial passive radar technology remains slow. This is due in part to technology immaturity, in part to politics, and particularly due to the fact that monostatic radars perform so well. If PBRs are to enjoy longevity as a viable technology then it is imperative that they address certain niche application areas, with the aforementioned MRR being one prime example of this. The focus of this paper will be an analysis of a PBR system that utilised FM radio signals of opportunity to detect aircraft targets with an RCS generally not lower than 20 m2. The paper will demonstrate the theoretical detection coverage of an FM based PBR operating in a severe interference environment.

  19. Psychoacoustics and Passive Sonar Detection

    DTIC Science & Technology

    1974-09-09

    al., 1956; Veniar, 1958; Swets, Shipley, McKey und Gree^., 1959; Creelman , 1960; Green, 1961; and Gundy, 1961). In general, the experiments first...Acoust. Soc. Am. 3_7. 1064, (1965). 5. CD. Creelman , "Detection of Signals of Uncertain Frequency", J. Acoust. Soc. Am. 32, 805, (1960). 6. J.P

  20. A Prognostic Methodology for Precipitation Phase Detection using GPM Microwave Observations —With Focus on Snow Cover

    NASA Astrophysics Data System (ADS)

    Takbiri, Z.; Ebtehaj, A.; Foufoula-Georgiou, E.; Kirstetter, P.

    2017-12-01

    Improving satellite retrieval of precipitation requires increased understanding of its passive microwave signature over different land surfaces. Passive microwave signals over snow-covered surfaces are notoriously difficult to interpret because they record both emission from the land below and absorption/scattering from the liquid/ice crystals. Using data from the Global Precipitation Measurement (GPM) core satellite, we demonstrate that the microwave brightness temperatures of rain and snowfall shifts from a scattering to an emission regime from summer to winter, due to expansion of the less emissive snow cover underneath. We present evidence that the combination of low- (10-19 GHz) and high-frequency (89-166 GHz) channels provides the maximum amount of information for snowfall detection. The study also examines a prognostic nearest neighbor matching method for the detection of precipitation and its phase from passive microwave observations using GPM data. The nearest neighbor uses the weighted Euclidean distance metric to search through an a priori database that is populated with coincident GPM radiometer and radar data as well as ancillary snow cover fraction. The results demonstrate prognostic capabilities of the proposed method in detection of terrestrial snowfall. At the global scale, the average probability of hit and false alarm reaches to 0.80 and remains below 0.10, respectively. Surprisingly, the results show that the snow cover may help to better detect precipitation as the detection rate of terrestrial precipitation is increased from 0.75 (no snow cover) to 0.84 (snow-covered surfaces). For solid precipitation, this increased rate of detection is larger than its liquid counterpart by almost 8%. The main reasons are found to be related to the multi-frequency capabilities of the nearest neighbor matching that can properly isolate the atmospheric signal from the background emission and the fact that the precipitation can exhibit an emission-like (warmer than surface) signature over fresh snow cover.

  1. [History of an epidemiological route between Ivory Coast and Burkina Faso: the case of the Koudougou sleeping sickness foci].

    PubMed

    Kiendrébéogo, D; Kambiré, R; Jamonneau, V; Lingué, K; Solano, P; Courtin, F

    2012-11-01

    In the first half of the XXth century, while Upper-Volta (now Burkina Faso) was suffering a terrible epidemic of sleeping sickness, the French colonial administration encouraged the movement of people from Upper-Volta to Ivory Coast to meet their demands for labour. This led to the establishment of Mossi villages, such as those of Koudougou, in the Ivorian forest with populations originating from areas of Upper-Volta that were not only densely populated but also severely affected by sleeping sickness. Since 2000, most cases of sleeping sickness in the Koudougou district of Burkina Faso have been in people originally from Ivory Coast. Who are they? Where did they settle in Burkina Faso? Where do they come from in Ivory Coast? After having retraced the epidemiological history of Koudougou villages in Burkina Faso and Ivory Coast, the history of ten cases of sleeping sickness detected passively at Koudougou hospital since 2000 were analysed. All cases originated from the forest area of Ivory Coast. Understanding the spread of sleeping sickness between Burkina Faso and Ivory Coast will assist in the identification of areas of disease risk.

  2. Four passive sampling elements (quatrefoil)--II. Film badges for monitoring radon and its progeny.

    PubMed

    Tommasino, L; Tokonami, S

    2011-05-01

    The four passive samplers (quatrefoil) already described in a parallel paper, make it possible to obtain thin radiation sources, useful for alpha and beta counting by any passive and real-time detector. In the present paper, the applications of this quatrefoil for measuring radon gas by etch-track detectors will be described. In the case of radon measurements, different solids have been identified, with radon-sorption partition coefficients related to air from 1 to 2000. Uniquely compact radon badges can be obtained by using a layer of these solids facing an alpha track-etch detector. These radon badges make it possible to overcome most of the shortcomings of existing passive monitors. Moreover, these badges show promise for studying the radon solubility of polymer films.

  3. The Role of Motor Learning in Spatial Adaptation near a Tool

    PubMed Central

    Brown, Liana E.; Doole, Robert; Malfait, Nicole

    2011-01-01

    Some visual-tactile (bimodal) cells have visual receptive fields (vRFs) that overlap and extend moderately beyond the skin of the hand. Neurophysiological evidence suggests, however, that a vRF will grow to encompass a hand-held tool following active tool use but not after passive holding. Why does active tool use, and not passive holding, lead to spatial adaptation near a tool? We asked whether spatial adaptation could be the result of motor or visual experience with the tool, and we distinguished between these alternatives by isolating motor from visual experience with the tool. Participants learned to use a novel, weighted tool. The active training group received both motor and visual experience with the tool, the passive training group received visual experience with the tool, but no motor experience, and finally, a no-training control group received neither visual nor motor experience using the tool. After training, we used a cueing paradigm to measure how quickly participants detected targets, varying whether the tool was placed near or far from the target display. Only the active training group detected targets more quickly when the tool was placed near, rather than far, from the target display. This effect of tool location was not present for either the passive-training or control groups. These results suggest that motor learning influences how visual space around the tool is represented. PMID:22174944

  4. Detecting ice lenses and melt-refreeze crusts using satellite passive microwaves (Invited)

    NASA Astrophysics Data System (ADS)

    Montpetit, B.; Royer, A.; Roy, A.

    2013-12-01

    With recent winter climate warming in high latitude regions, rain-on-snow and melt-refreeze events are more frequent creating ice lenses or ice crusts at the surface or even within the snowpack through drainage. These ice layers create an impermeable ice barrier that reduces vegetation respiration and modifies snow properties due to the weak thermal diffusivity of ice. Winter mean soil temperatures increase due to latent heat being released during the freezing process. When ice layers freeze at the snow-soil interface, they can also affect the feeding habits of the northern wild life. Ice layers also significantly affect satellite passive microwave signals that are widely used to monitor the spatial and temporal evolution of snow. Here we present a method using satellite passive microwave brightness temperatures (Tb) to detect ice lenses and/or ice crusts within a snowpack. First the Microwave Emission Model for Layered Snowpacks (MEMLS) was validated to model Tb at 10.7, 19 and 37 GHz using in situ measurements taken in multiple sub-arctic environments where ice layers where observed. Through validated modeling, the effects of ice layer insertion were studied and an ice layer index was developed using the polarization ratio (PR) at all three frequencies. The developed ice index was then applied to satellite passive microwave signals for reported ice layer events.

  5. Thermal analysis of insulated north-wall greenhouse with solar collector under passive mode

    NASA Astrophysics Data System (ADS)

    Chauhan, Prashant Singh; Kumar, Anil

    2018-04-01

    An insulated north wall greenhouse dryer has been fabricated and tested for no-load condition under passive mode. Testing has been conducted in two different cases. Case-I is considered for solar collector kept inside the dryer and Case-II is dryer without solar collector. Convective heat transfer coefficient and various heat transfer dimensionless numbers with have been calculated for thermal analysis. The maximum convective heat transfer coefficient is found 52.18 W/m2°C at 14 h during the first day for Case-I. The difference of the highest convective heat transfer coefficient of both cases was 8.34 W/m2°C. Net heat gain inside room curves are uniform and smooth for Case-I, which shows the steady heat generation process due to presence of solar collector inside the dryer. Above results depicts the effectiveness of solar collector and insulated north wall. The selection of suitable crop for drying can be done by analysing article's result.

  6. Passive range estimation using dual baseline triangulation

    NASA Astrophysics Data System (ADS)

    Pieper, Ronald J.; Cooper, Alfred W.; Pelegris, G.

    1996-03-01

    Modern combat systems based on active radar sensing suffer disadvantages against low-flying targets in cluttered backgrounds. Use of passive infrared sensors with these systems, either in cooperation or as an alternative, shows potential for improving target detection and declaration range for targets crossing the horizon. Realization of this potential requires fusion of target position data from dissimilar sensors, or passive sensor measurement of target range. The availability of passive sensors that can supply both range and bearing data on such targets would significantly extend the robustness of an integrated ship self-defense system. This paper considers a new method of range determination with passive sensors based on the principle of triangulation, extending the principle to two orthogonal baselines. The performance of single or double baseline triangulation depends on sensor bearing precision and direction to target. An expression for maximum triangulation range at a required accuracy is derived as a function of polar angle relative to the center of the dual-baseline system. Limitations in the dual- baseline model due to the geometrically assessed horizon are also considered.

  7. Making working memory work: a meta-analysis of executive-control and working memory training in older adults.

    PubMed

    Karbach, Julia; Verhaeghen, Paul

    2014-11-01

    This meta-analysis examined the effects of process-based executive-function and working memory training (49 articles, 61 independent samples) in older adults (> 60 years). The interventions resulted in significant effects on performance on the trained task and near-transfer tasks; significant results were obtained for the net pretest-to-posttest gain relative to active and passive control groups and for the net effect at posttest relative to active and passive control groups. Far-transfer effects were smaller than near-transfer effects but were significant for the net pretest-to-posttest gain relative to passive control groups and for the net gain at posttest relative to both active and passive control groups. We detected marginally significant differences in training-induced improvements between working memory and executive-function training, but no differences between the training-induced improvements observed in older adults and younger adults, between the benefits associated with adaptive and nonadaptive training, or between the effects in active and passive control conditions. Gains did not vary with total training time. © The Author(s) 2014.

  8. Possibility of passive THz camera using for a temperature difference observing of objects placed inside the human body

    NASA Astrophysics Data System (ADS)

    Trofimov, Vyacheslav A.; Trofimov, Vladislav V.; Kuchik, Igor E.

    2014-06-01

    As it is well-known, application of the passive THz camera for the security problems is very promising way. It allows seeing concealed object without contact with a person and this camera is non-dangerous for a person. We demonstrate new possibility of the passive THz camera using for a temperature difference observing on the human skin if this difference is caused by different temperatures inside the body. We discuss some physical experiments, in which a person drinks hot, and warm, and cold water and he eats. After computer processing of images captured by passive THz camera TS4 we may see the pronounced temperature trace on skin of the human body. For proof of validity of our statement we make the similar physical experiment using the IR camera. Our investigation allows to increase field of the passive THz camera using for the detection of objects concealed in the human body because the difference in temperature between object and parts of human body will be reflected on the human skin. However, modern passive THz cameras have not enough resolution in a temperature to see this difference. That is why, we use computer processing to enhance the camera resolution for this application. We consider images produced by THz passive cameras manufactured by Microsemi Corp., and ThruVision Corp.

  9. Trends in Animal Rabies Surveillance in the Endemic State of Minas Gerais, Brazil

    PubMed Central

    Oviedo-Pastrana, Misael E.; Oliveira, Camila S. F.; Capanema, Renato O.; Nicolino, Rafael R.; Oviedo-Socarras, Teresa J.; Haddad, João Paulo A.

    2015-01-01

    Rabies is a viral zoonosis affecting mammal species and causes large economic losses. Included among the neglected diseases, it is still insufficiently addressed by governments and the international community, despite formal surveillance and control programs. This study used a dataset of 10,112 rabies diagnoses in animals provided by the Brazilian passive surveillance system from 2001 to 2012. The positivity rate of the tested samples was 26.4%, and a reduction in the total samples sent during the last six years was observed. The kernel density map indicated case concentration in the south region and a decrease in density of rabies cases in the second period studied (2007 to 2012). The directional trend of positive rabies diagnoses remained in the south region, as shown by the standard deviational ellipse. The spatial scan statistic identified three large clusters of positive diagnoses, one in the first period (2001-2006) and two in the second period (2007-2012), indicating an expansion of risk areas. The decrease in rabies cases from 2006 to 2012 does not necessarily reflect lower viral circulation or improvement in actions by epidemiological surveillance; this decrease could indicate a deficiency in epidemiological surveillance during the observation period due to the increase in the silent areas. Surveillance should maintain an increasing or constant number of tests during the years in addition to a reduction in the number of outbreaks of rabies, which would indicate a lower positivity rate. The findings in this study indicate deterioration in the effectiveness of the passive surveillance for rabies. The number of rabies cases, total number of tests performed and positivity rate are good indicators for evaluating passive surveillance. This paper can function as a guide for the assessment and improvement of the actions in passive surveillance of rabies. PMID:25774775

  10. A stereo-vision hazard-detection algorithm to increase planetary lander autonomy

    NASA Astrophysics Data System (ADS)

    Woicke, Svenja; Mooij, Erwin

    2016-05-01

    For future landings on any celestial body, increasing the lander autonomy as well as decreasing risk are primary objectives. Both risk reduction and an increase in autonomy can be achieved by including hazard detection and avoidance in the guidance, navigation, and control loop. One of the main challenges in hazard detection and avoidance is the reconstruction of accurate elevation models, as well as slope and roughness maps. Multiple methods for acquiring the inputs for hazard maps are available. The main distinction can be made between active and passive methods. Passive methods (cameras) have budgetary advantages compared to active sensors (radar, light detection and ranging). However, it is necessary to proof that these methods deliver sufficiently good maps. Therefore, this paper discusses hazard detection using stereo vision. To facilitate a successful landing not more than 1% wrong detections (hazards that are not identified) are allowed. Based on a sensitivity analysis it was found that using a stereo set-up at a baseline of ≤ 2 m is feasible at altitudes of ≤ 200 m defining false positives of less than 1%. It was thus shown that stereo-based hazard detection is an effective means to decrease the landing risk and increase the lander autonomy. In conclusion, the proposed algorithm is a promising candidate for future landers.

  11. Short-Term Behavioural Responses of the Great Scallop Pecten maximus Exposed to the Toxic Alga Alexandrium minutum Measured by Accelerometry and Passive Acoustics.

    PubMed

    Coquereau, Laura; Jolivet, Aurélie; Hégaret, Hélène; Chauvaud, Laurent

    2016-01-01

    Harmful algal blooms produced by toxic dinoflagellates have increased worldwide, impacting human health, the environment, and fisheries. Due to their potential sensitivity (e.g., environmental changes), bivalves through their valve movements can be monitored to detect harmful algal blooms. Methods that measure valve activity require bivalve-attached sensors and usually connected cables to data transfers, leading to stress animals and limit the use to sessile species. As a non-intrusive and continuously deployable tool, passive acoustics could be an effective approach to detecting harmful algal blooms in real time based on animal sound production. This study aimed to detect reaction changes in the valve movements of adult Pecten maximus exposed to the toxic dinoflagellate Alexandrium minutum using both accelerometry and passive acoustic methods. Scallops were experimentally exposed to three ecologically relevant concentrations of A. minutum for 2 hours. The number of each type of valve movement and their sound intensity, opening duration, and valve-opening amplitude were measured. Four behaviours were identified: closures, expulsion, displacement, and swimming. The response of P. maximus to A. minutum occurred rapidly at a high concentration. The valve activity of P. maximus was different when exposed to high concentrations (500 000 cells L-1) of A. minutum compared to the non-toxic dinoflagellate Heterocapsa triquetra; the number of valve movements increased, especially closure and expulsion, which were detected acoustically. Thus, this study demonstrates the potential for acoustics and sound production changes in the detection of harmful algal blooms. However, field trials and longer duration experiments are required to provide further evidence for the use of acoustics as a monitoring tool in the natural environment where several factors may interfere with valve behaviours.

  12. Short-Term Behavioural Responses of the Great Scallop Pecten maximus Exposed to the Toxic Alga Alexandrium minutum Measured by Accelerometry and Passive Acoustics

    PubMed Central

    Coquereau, Laura; Jolivet, Aurélie; Hégaret, Hélène; Chauvaud, Laurent

    2016-01-01

    Harmful algal blooms produced by toxic dinoflagellates have increased worldwide, impacting human health, the environment, and fisheries. Due to their potential sensitivity (e.g., environmental changes), bivalves through their valve movements can be monitored to detect harmful algal blooms. Methods that measure valve activity require bivalve-attached sensors and usually connected cables to data transfers, leading to stress animals and limit the use to sessile species. As a non-intrusive and continuously deployable tool, passive acoustics could be an effective approach to detecting harmful algal blooms in real time based on animal sound production. This study aimed to detect reaction changes in the valve movements of adult Pecten maximus exposed to the toxic dinoflagellate Alexandrium minutum using both accelerometry and passive acoustic methods. Scallops were experimentally exposed to three ecologically relevant concentrations of A. minutum for 2 hours. The number of each type of valve movement and their sound intensity, opening duration, and valve-opening amplitude were measured. Four behaviours were identified: closures, expulsion, displacement, and swimming. The response of P. maximus to A. minutum occurred rapidly at a high concentration. The valve activity of P. maximus was different when exposed to high concentrations (500 000 cells L-1) of A. minutum compared to the non-toxic dinoflagellate Heterocapsa triquetra; the number of valve movements increased, especially closure and expulsion, which were detected acoustically. Thus, this study demonstrates the potential for acoustics and sound production changes in the detection of harmful algal blooms. However, field trials and longer duration experiments are required to provide further evidence for the use of acoustics as a monitoring tool in the natural environment where several factors may interfere with valve behaviours. PMID:27508498

  13. Benefits of Stimulus Exposure: Developmental Learning Independent of Task Performance

    PubMed Central

    Green, David B.; Ohlemacher, Jocelyn; Rosen, Merri J.

    2016-01-01

    Perceptual learning (training-induced performance improvement) can be elicited by task-irrelevant stimulus exposure in humans. In contrast, task-irrelevant stimulus exposure in animals typically disrupts perception in juveniles while causing little to no effect in adults. This may be due to the extent of exposure, which is brief in humans while chronic in animals. Here we assessed the effects of short bouts of passive stimulus exposure on learning during development in gerbils, compared with non-passive stimulus exposure (i.e., during testing). We used prepulse inhibition of the acoustic startle response, a method that can be applied at any age, to measure gap detection thresholds across four age groups, spanning development. First, we showed that both gap detection thresholds and gap detection learning across sessions displayed a long developmental trajectory, improving throughout the juvenile period. Additionally, we demonstrated larger within- and across-animal performance variability in younger animals. These results are generally consistent with results in humans, where there are extended developmental trajectories for both the perception of temporally-varying signals, and the effects of perceptual training, as well as increased variability and poorer performance consistency in children. We then chose an age (mid-juveniles) that displayed clear learning over sessions in order to assess effects of brief passive stimulus exposure on this learning. We compared learning in mid-juveniles exposed to either gap detection testing (gaps paired with startles) or equivalent gap exposure without testing (gaps alone) for three sessions. Learning was equivalent in both these groups and better than both naïve age-matched animals and controls receiving no gap exposure but only startle testing. Thus, short bouts of exposure to gaps independent of task performance is sufficient to induce learning at this age, and is as effective as gap detection testing. PMID:27378837

  14. Dual-mode microwave system to enhance early detection of cancer

    NASA Technical Reports Server (NTRS)

    Carr, K. L.; El-Mahdi, A. M.; Shaeffer, J.

    1981-01-01

    A dual-mode microwave system has been developed that will permit early detection of cancer. The system combines the use of the passive microwave radiometer with an active transmitter. The active transmitter will provide localized heating to enhance early detection by taking advantage of the differential heating (i.e., tumor temperature with respect to surrounding tissue) associated with the thermal characteristics of tumors.

  15. Ferromagnetic Objects Magnetovision Detection System.

    PubMed

    Nowicki, Michał; Szewczyk, Roman

    2013-12-02

    This paper presents the application of a weak magnetic fields magnetovision scanning system for detection of dangerous ferromagnetic objects. A measurement system was developed and built to study the magnetic field vector distributions. The measurements of the Earth's field distortions caused by various ferromagnetic objects were carried out. The ability for passive detection of hidden or buried dangerous objects and the determination of their location was demonstrated.

  16. Thick-Filament Strain and Interfilament Spacing in Passive Muscle: Effect of Titin-Based Passive Tension

    PubMed Central

    Irving, Thomas; Wu, Yiming; Bekyarova, Tanya; Farman, Gerrie P.; Fukuda, Norio; Granzier, Henk

    2011-01-01

    We studied the effect of titin-based passive tension on sarcomere structure by simultaneously measuring passive tension and low-angle x-ray diffraction patterns on passive fiber bundles from rabbit skinned psoas muscle. We used a stretch-hold-release protocol with measurement of x-ray diffraction patterns at various passive tension levels during the hold phase before and after passive stress relaxation. Measurements were performed in relaxing solution without and with dextran T-500 to compress the lattice toward physiological levels. The myofilament lattice spacing was measured in the A-band (d1,0) and Z-disk (dZ) regions of the sarcomere. The axial spacing of the thick-filament backbone was determined from the sixth myosin meridional reflection (M6) and the equilibrium positions of myosin heads from the fourth myosin layer line peak position and the I1,1/I1,0 intensity ratio. Total passive tension was measured during the x-ray experiments, and a differential extraction technique was used to determine the relations between collagen- and titin-based passive tension and sarcomere length. Within the employed range of sarcomere lengths (∼2.2–3.4 μm), titin accounted for >80% of passive tension. X-ray results indicate that titin compresses both the A-band and Z-disk lattice spacing with viscoelastic behavior when fibers are swollen after skinning, and elastic behavior when the lattice is reduced with dextran. Titin also increases the axial thick-filament spacing, M6, in an elastic manner in both the presence and absence of dextran. No changes were detected in either I1,1/I1,0 or the position of peaks on the fourth myosin layer line during passive stress relaxation. Passive tension and M6 measurements were converted to thick-filament compliance, yielding a value of ∼85 m/N, which is several-fold larger than the thick-filament compliance determined by others during the tetanic tension plateau of activated intact muscle. This difference can be explained by the fact that thick filaments are more compliant at low tension (passive muscle) than at high tension (tetanic tension). The implications of our findings are discussed. PMID:21402032

  17. Passive margins getting squeezed in the mantle convection vice

    NASA Astrophysics Data System (ADS)

    Yamato, Philippe; Husson, Laurent; Becker, Thorsten W.; Pedoja, Kevin

    2013-12-01

    margins often exhibit uplift, exhumation, and tectonic inversion. We speculate that the compression in the lithosphere gradually increased during the Cenozoic, as seen in the number of mountain belts found at active margins during that period. Less clear is how that compression increase affects passive margins. In order to address this issue, we design a 2-D viscous numerical model wherein a lithospheric plate rests above a weaker mantle. It is driven by a mantle conveyor belt, alternatively excited by a lateral downwelling on one side, an upwelling on the other side, or both simultaneously. The lateral edges of the plate are either free or fixed, representing the cases of free convergence, and collision (or slab anchoring), respectively. This distinction changes the upper mechanical boundary condition for mantle circulation and thus, the stress field. Between these two regimes, the flow pattern transiently evolves from a free-slip convection mode toward a no-slip boundary condition above the upper mantle. In the second case, the lithosphere is highly stressed horizontally and deforms. For a constant total driving force, compression increases drastically at passive margins if upwellings are active. Conversely, if downwellings alone are activated, compression occurs at short distances from the trench and extension prevails elsewhere. These results are supported by Earth-like models that reveal the same pattern, where active upwellings are required to excite passive margins compression. Our results substantiate the idea that compression at passive margins is in response to the underlying mantle flow that is increasingly resisted by the Cenozoic collisions.

  18. Preliminary Field Demonstration of Passive Radio Sounding Using the Sun as a Signal for Echo Detection

    NASA Astrophysics Data System (ADS)

    Peters, S. T.; Schroeder, D. M.; Romero-Wolf, A.; Haynes, M.

    2017-12-01

    The Radar for Icy Moon Exploration (RIME) and the Radar for Europa Assessment and Sounding: Ocean to Near-surface (REASON) have been identified as potential candidates for the implementation of passive sounding as additional observing modes for the ESA and NASA missions to Ganymede and Europa. Recent work has shown the theoretical potential for Jupiter's decametric radiation to be used as a source for passive radio sounding of its icy moons. We are further developing and adapting this geophysical approach for use in terrestrial glaciology. Here, we present results from preliminary field testing of a prototype passive radio sounder from cliffs along the California coast. This includes both using a Lloyd's mirror to measure the Sun's direct path and its reflection off the ocean's surface and exploiting autocorrelation to detect the delay time of the echo. This is the first in-situ demonstration of the autocorrelation-based passive-sounding approach using an astronomical white noise signal. We also discuss preliminary field tests on rougher terrestrial and subglacial surfaces, including at Store Glacier in Greenland. Additionally, we present modeling and experimental results that demonstrate the feasibility of applying presumming approaches to the autocorrelations to achieve coherent gain from an inherently random signal. We note that while recording with wider bandwidths and greater delays places fundamental limits on the Lloyd's mirror approach, our new autocorrelation method has no such limitation. Furthermore, we show how achieving wide bandwidths via spectral-stitching methods allows us to obtain a finer range resolution than given by the receiver's instantaneous bandwidth. Finally, we discuss the potential for this technique to eliminate the need for active transmitters in certain types of ice sounding experiments, thereby reducing the complexity, power consumption, and cost of systems and observations.

  19. Real-time computer treatment of THz passive device images with the high image quality

    NASA Astrophysics Data System (ADS)

    Trofimov, Vyacheslav A.; Trofimov, Vladislav V.

    2012-06-01

    We demonstrate real-time computer code improving significantly the quality of images captured by the passive THz imaging system. The code is not only designed for a THz passive device: it can be applied to any kind of such devices and active THz imaging systems as well. We applied our code for computer processing of images captured by four passive THz imaging devices manufactured by different companies. It should be stressed that computer processing of images produced by different companies requires using the different spatial filters usually. The performance of current version of the computer code is greater than one image per second for a THz image having more than 5000 pixels and 24 bit number representation. Processing of THz single image produces about 20 images simultaneously corresponding to various spatial filters. The computer code allows increasing the number of pixels for processed images without noticeable reduction of image quality. The performance of the computer code can be increased many times using parallel algorithms for processing the image. We develop original spatial filters which allow one to see objects with sizes less than 2 cm. The imagery is produced by passive THz imaging devices which captured the images of objects hidden under opaque clothes. For images with high noise we develop an approach which results in suppression of the noise after using the computer processing and we obtain the good quality image. With the aim of illustrating the efficiency of the developed approach we demonstrate the detection of the liquid explosive, ordinary explosive, knife, pistol, metal plate, CD, ceramics, chocolate and other objects hidden under opaque clothes. The results demonstrate the high efficiency of our approach for the detection of hidden objects and they are a very promising solution for the security problem.

  20. [The consequences of passive smoking in adults].

    PubMed

    Trédaniel, J; Savinelli, F; Vignot, S; Bousquet, G; Le Maignan, C; Misset, J-L

    2006-04-01

    Passive smoking is the involuntary inhalation by a non-smoker of smoke generated in his neighbourhood by one or more smokers. The effect of this exposure is already generally recognised in children. In adults the induction of chronic obstructive lung disease has not been demonstrated. This is no longer the case for ischaemic heart disease and lung cancer where the effect of passive exposure of non-smokers to cigarette smoke is recognised. The biological plausibility together with the concordance of results obtained over successive years, as well as the large numbers of patients included in the studies, lead to a confident conclusion that the risks in adult non-smokers are increased by the order of 25%. There is no evidence that bias affects the conclusions reached and the World Health Organisation has recently classified passive smoking as being carcinogenic in man. As a result of these data prevention of passive exposure to cigarette smoke should be part of a larger framework of smoking prevention, especially among the young.

  1. Gas-diffusion-based passive sampler for ammonia monitoring in marine waters.

    PubMed

    O'Connor Šraj, Lenka; Almeida, M Inês G S; Bassett, Chelsea; McKelvie, Ian D; Kolev, Spas D

    2018-05-01

    A novel passive sampler based on gas-diffusion across a hydrophobic membrane is described for the determination of the time-weighted average concentration of dissolved molecular ammonia in high ionic strength aquatic environments, such as sea, coastal and estuarine waters, for a period of 3 days. The passive sampler developed is cheap, easy-to-use, reusable, and has a dynamic concentration range of 2.0-12µM, which covers the water quality guideline trigger value of 11.4µM (160µgL -1 NH 3 -N) for high conservation value waters, making this a powerful new tool for water quality managers involved in long-term ammonia monitoring. The gas-diffusion-based passive sampler was calibrated under laboratory conditions and deployed in a tank of seawater in the laboratory and at an estuarine site for proof of concept, and a good agreement between passive and spot sampling was achieved in both cases. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Should we consider IgG hypogammaglobulinemia a risk factor for severe complications of Ludwig angina?

    PubMed Central

    Baez-Pravia, Orville V.; Díaz-Cámara, Miriam; De La Sen, Oscar; Pey, Carlos; Ontañón Martín, Mercedes; Jimenez Hiscock, Luis; Morató Bellido, Begoña; Córdoba Sánchez, Ángel Luis

    2017-01-01

    Abstract Rationale: Cervical necrotizing fasciitis (CNF) and descending necrotizing mediastinitis (DNM) are rare forms of complication of Ludwig angina. These potentially lethal infections are difficult to recognize in early stages and are often associated with predisposing factors like diabetes and immunocompromised states. Moreover, IgG hypogammaglobulinemia (hypo-IgG) is considered to be a risk factor of mortality in patients with septic shock; however, it is not routinely quantified in patients with extremely serious infections, particularly in cases with no history or evidence of immunocompromising disorders. Patient concerns: We present a case of a 58-year-old woman who survived Ludwig angina, complicated by CNF and DNM. Despite a rapid diagnosis, aggressive surgical debridement and broad-spectrum antibiotics, the infection and necrosis advanced, requiring multiple surgical interventions and long intensive care unit (ICU) support. Conclusion: We hypothesize that detecting a low level of endogenous IgG and treating with adjuvant passive immunotherapy was key in determining a favorable outcome. PMID:29381958

  3. Advanced radiometric and interferometric milimeter-wave scene simulations

    NASA Technical Reports Server (NTRS)

    Hauss, B. I.; Moffa, P. J.; Steele, W. G.; Agravante, H.; Davidheiser, R.; Samec, T.; Young, S. K.

    1993-01-01

    Smart munitions and weapons utilize various imaging sensors (including passive IR, active and passive millimeter-wave, and visible wavebands) to detect/identify targets at short standoff ranges and in varied terrain backgrounds. In order to design and evaluate these sensors under a variety of conditions, a high-fidelity scene simulation capability is necessary. Such a capability for passive millimeter-wave scene simulation exists at TRW. TRW's Advanced Radiometric Millimeter-Wave Scene Simulation (ARMSS) code is a rigorous, benchmarked, end-to-end passive millimeter-wave scene simulation code for interpreting millimeter-wave data, establishing scene signatures and evaluating sensor performance. In passive millimeter-wave imaging, resolution is limited due to wavelength and aperture size. Where high resolution is required, the utility of passive millimeter-wave imaging is confined to short ranges. Recent developments in interferometry have made possible high resolution applications on military platforms. Interferometry or synthetic aperture radiometry allows the creation of a high resolution image with a sparsely filled aperture. Borrowing from research work in radio astronomy, we have developed and tested at TRW scene reconstruction algorithms that allow the recovery of the scene from a relatively small number of spatial frequency components. In this paper, the TRW modeling capability is described and numerical results are presented.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowla, F

    Long-range, ultra-wideband (UWB), passive radio frequency (RF) tags are key components in Radio Frequency IDentification (RFID) system that will revolutionize inventory control and tracking applications. Unlike conventional, battery-operated (active) RFID tags, LLNL's small UWB tags, called 'UTag', operate at long range (up to 20 meters) in harsh, cluttered environments. Because they are battery-less (that is, passive), they have practically infinite lifetimes without human intervention, and they are lower in cost to manufacture and maintain than active RFID tags. These robust, energy-efficient passive tags are remotely powered by UWB radio signals, which are much more difficult to detect, intercept, and jammore » than conventional narrowband frequencies. The features of long range, battery-less, and low cost give UTag significant advantage over other existing RFID tags.« less

  5. [Remote sensing of atmospheric trace gas by airborne passive FTIR].

    PubMed

    Gao, Min-quang; Liu, Wen-qing; Zhang, Tian-shu; Liu, Jian-guo; Lu, Yi-huai; Wang, Ya-ping; Xu, Liang; Zhu, Jun; Chen, Jun

    2006-12-01

    The present article describes the details of aviatic measurement for remote sensing trace gases in atmosphere under various surface backgrounds with airborne passive FTIR. The passive down viewing and remote sensing technique used in the experiment is discussed. The method of acquiring atmospheric trace gases infrared characteristic spectra in complicated background and the algorithm of concentration retrieval are discussed. The concentrations of CO and N2O of boundary-layer atmosphere in experimental region below 1000 m are analyzed quantitatively. This measurement technique and the data analysis method, which does not require a previously measured background spectrum, allow fast and mobile remote detection and identification of atmosphere trace gas in large area, and also can be used for urgent monitoring of pollution accidental breakout.

  6. Multi-channel, passive, short-range anti-aircraft defence system

    NASA Astrophysics Data System (ADS)

    Gapiński, Daniel; Krzysztofik, Izabela; Koruba, Zbigniew

    2018-01-01

    The paper presents a novel method for tracking several air targets simultaneously. The developed concept concerns a multi-channel, passive, short-range anti-aircraft defence system based on the programmed selection of air targets and an algorithm of simultaneous synchronisation of several modified optical scanning seekers. The above system is supposed to facilitate simultaneous firing of several self-guided infrared rocket missiles at many different air targets. From the available information, it appears that, currently, there are no passive self-guided seekers that fulfil such tasks. This paper contains theoretical discussions and simulations of simultaneous detection and tracking of many air targets by mutually integrated seekers of several rocket missiles. The results of computer simulation research have been presented in a graphical form.

  7. Experimental study of a smart foam sound absorber.

    PubMed

    Leroy, Pierre; Berry, Alain; Herzog, Philippe; Atalla, Noureddine

    2011-01-01

    This article presents the experimental implementation and results of a hybrid passive/active absorber (smart foam) made up from the combination of a passive absorbent (foam) and a curved polyvinylidene fluoride (PVDF) film actuator bonded to the rear surface of the foam. Various smart foam prototypes were built and tested in active absorption experiments conducted in an impedance tube under plane wave propagation condition at frequencies between 100 and 1500 Hz. Three control cases were tested. The first case used a fixed controller derived in the frequency domain from estimations of the primary disturbance at a directive microphone position in the tube and the transfer function between the control PVDF and the directive microphone. The two other cases used an adaptive time-domain feedforward controller to absorb either a single-frequency incident wave or a broadband incident wave. The non-linearity of the smart foams and the causality constraint were identified to be important factors influencing active control performance. The effectiveness of the various smart foam prototypes is discussed in terms of the active and passive absorption coefficients as well as the control voltage of the PVDF actuator normalized by the incident sound pressure.

  8. Performance Evaluation of Passive Haptic Feedback for Tactile HMI Design in CAVEs.

    PubMed

    Lassagne, Antoine; Kemeny, Andras; Posselt, Javier; Merienne, Frederic

    2018-01-01

    This article presents a comparison of different haptic systems, which are designed to simulate flat Human Machine Interfaces (HMIs) like touchscreens in virtual environments (VEs) such as CAVEs, and their respective performance. We compare a tangible passive transparent slate to a classic tablet and a sensory substitution system. These systems were tested during a controlled experiment. The performance and impressions from 20 subjects were collected to understand more about the modalities in the given context. The results show that the preferences of the subjects are strongly related to the use-cases and needs. In terms of performance, passive haptics proved to be significantly useful, acting as a space reference and a real-time continuous calibration system, allowing subjects to have lower execution durations and relative errors. Sensory substitution induced perception drifts during the experiment, causing significant performance disparities, demonstrating the low robustness of perception when spatial cues are insufficiently available. Our findings offer a better understanding on the nature of perception drifts and the need of strong multisensory spatial markers for such use-cases in CAVEs. The importance of a relevant haptic modality specifically designed to match a precise use-case is also emphasized.

  9. Electrophysiological Correlates of the Threshold to Detection of Passive Motion: An Investigation in Professional Volleyball Athletes with and without Atrophy of the Infraspinatus Muscle

    PubMed Central

    Salles, José Inácio; Cossich, Victor Rodrigues Amaral; Amaral, Marcus Vinicius; Monteiro, Martim T.; Cagy, Maurício; Motta, Geraldo; Velasques, Bruna; Piedade, Roberto; Ribeiro, Pedro

    2013-01-01

    The goal of the present study is to compare the electrophysiological correlates of the threshold to detection of passive motion (TTDPM) among three groups: healthy individuals (control group), professional volleyball athletes with atrophy of the infraspinatus muscle on the dominant side, and athletes with no shoulder pathologies. More specifically, the study aims at assessing the effects of infraspinatus muscle atrophy on the cortical representation of the TTDPM. A proprioception testing device (PTD) was used to measure the TTDPM. The device passively moved the shoulder and participants were instructed to respond as soon as movement was detected (TTDPM) by pressing a button switch. Response latency was established as the delay between the stimulus (movement) and the response (button press). Electroencephalographic (EEG) and electromyographic (EMG) activities were recorded simultaneously. An analysis of variance (ANOVA) and subsequent post hoc tests indicated a significant difference in latency between the group of athletes without the atrophy when compared both to the group of athletes with the atrophy and to the control group. Furthermore, distinct patterns of cortical activity were observed in the three experimental groups. The results suggest that systematically trained motor abilities, as well as the atrophy of the infraspinatus muscle, change the cortical representation of the different stages of proprioceptive information processing and, ultimately, the cortical representation of the TTDPM. PMID:23484136

  10. High Resolution Freeze and Thaw States Detection Using Combination of Sentinel 1A SAR and Passive Microwave Measurements

    NASA Astrophysics Data System (ADS)

    Azarderakhsh, M.; McDonald, K. C.; Norouzi, H.; Rebolledo, M. A.; Prakash, S.

    2017-12-01

    The freeze and thaw (FT) cycles in high-latitude regions have great impact on many biogeochemical transitions, hydrology and ecosystem especially in wetland areas. Passive and active microwave remote sensing data from satellite observations have been deployed in the past to define the status of the surface in terms of freeze and thaw. While many progresses have been made in this field, the limitations attached to such observations have hindered our ability to fully predict the change of surface state in the scale that is appropriate for the aforementioned applications. The transition between freeze and thaw states may occur frequently (even within a day) especially during shifts from cold to warm seasons and vice versa. Passive microwave sensors have different acquisition times, and data fusion of these sensors may provide a complete diurnal variation estimate of FT states. However, the coarse spatial resolution of these measurements may undermine their applicability. However, active microwave backscatter measurements from sensors such as Sentinel 1A and the Advanced Land Observing Satellite Phased Array L-Band SAR (ALOS PALSAR) can deliver high resolution information about wetlands and FT status. In this project, Synthetic Aperture Radar (SAR) c-band backscatter data from Sentinel 1 from April 2014 to June 2017 are deployed to detect high resolution freeze/thaw states and wetland areas. The contrasts between frozen and thawed seasons are used to define FT states after performing required radiometric corrections and calibrations. A method based on phase changes in polarized images is developed for different land cover types to maximize the accuracy of the detections. The aggregated (up-scaled) estimates from active measurements are compared to passive microwave-based FT product. The results of this method reveal that the estimates are relatively in good agreement with SNOw TELemetry (SNOTEL) ground measurements. Finally, a downscaling method is tried to link passive emissivity-based FT product to high resolution active FT estimates to increase the temporal frequency of the high-resolution Sentinel data. The results of this study contribute to better understanding sources of positive carbon and methane (CH4) feedback to the atmosphere.

  11. A dual-mode hemispherical sparse array for 3D passive acoustic mapping and skull localization within a clinical MRI guided focused ultrasound device

    NASA Astrophysics Data System (ADS)

    Crake, Calum; Brinker, Spencer T.; Coviello, Christian M.; Livingstone, Margaret S.; McDannold, Nathan J.

    2018-03-01

    Previous work has demonstrated that passive acoustic imaging may be used alongside MRI for monitoring of focused ultrasound therapy. However, past implementations have generally made use of either linear arrays originally designed for diagnostic imaging or custom narrowband arrays specific to in-house therapeutic transducer designs, neither of which is fully compatible with clinical MR-guided focused ultrasound (MRgFUS) devices. Here we have designed an array which is suitable for use within an FDA-approved MR-guided transcranial focused ultrasound device, within the bore of a 3 Tesla clinical MRI scanner. The array is constructed from 5  ×  0.4 mm piezoceramic disc elements arranged in pseudorandom fashion on a low-profile laser-cut acrylic frame designed to fit between the therapeutic elements of a 230 kHz InSightec ExAblate 4000 transducer. By exploiting thickness and radial resonance modes of the piezo discs the array is capable of both B-mode imaging at 5 MHz for skull localization, as well as passive reception at the second harmonic of the therapy array for detection of cavitation and 3D passive acoustic imaging. In active mode, the array was able to perform B-mode imaging of a human skull, showing the outer skull surface with good qualitative agreement with MR imaging. Extension to 3D showed the array was able to locate the skull within  ±2 mm/2° of reference points derived from MRI, which could potentially allow registration of a patient to the therapy system without the expense of real-time MRI. In passive mode, the array was able to resolve a point source in 3D within a  ±10 mm region about each axis from the focus, detect cavitation (SNR ~ 12 dB) at burst lengths from 10 cycles to continuous wave, and produce 3D acoustic maps in a flow phantom. Finally, the array was used to detect and map cavitation associated with microbubble activity in the brain in nonhuman primates.

  12. A Novel Passive Millimeter Imager for Broad-Area Search - Final Report on Project PL09-NPMI-PD07 (PNNL-55180)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Bernacki, Bruce E.; Kelly, James F.

    2011-12-31

    This report describes research and development efforts toward a novel passive millimeter-wave (mm-wave) electromagnetic imaging device for broad-area search. It addresses the technical challenge of detecting anomalies that occupy a small fraction of a pixel. The purpose of the imager is to pinpoint suspicious locations for cuing subsequent higher-resolution imaging. The technical basis for the approach is to exploit thermal and polarization anomalies that distinguish man-made features from natural features.

  13. Washington State Play Fairway Analysis - Passive Monitoring of St. Helens Shear Zone for Tomography and Precision Microseismic Event Detection

    DOE Data Explorer

    Swyer, Michael (ORCID:0000000309776975); Cladouhos, Trenton; Crosbie, Kayla; Ulberg, Carl (ORCID:000000016198809X)

    2017-10-03

    Data resources were derived from a passive seismic survey of the northern St. Helens Shear Zone on geothermal leases 12-24 km north of Mount St. Helens for phase 2 of the Geothermal Play-Fairway Analysis of Washington State Prospects. A 20 seismic station array of broadband seismometers was deployed with irregular spacing (1-4 km) over an area of 12 km to image seismogenic features and their damage zones in the shallow crust.

  14. Advances in Components for Active and Passive Airborne Sensors (Progres des Composants pour les Systemes des Detection Active et Passive Aeroportes)

    DTIC Science & Technology

    1990-09-01

    simplest form the modulators are systems. 1) The inter -band absorption edges at operated as non-resonant (single-pass) which the electro-absorption...transitions in -0111- 1,’. three different wavelength bands indicated. It is the NIR inter -band transition which is of interest in this E’l Iwork. 0...quartz crystal resonator is a vector quantity. 12 random vibration at 100 Hz away from the Therefore, the frequency during acceleration carrier. Of

  15. Clinical outcome of calves with failure of passive transfer as diagnosed by a commercially available IgG quick test kit

    PubMed Central

    Stilwell, George; Carvalho, Rita C.

    2011-01-01

    The efficacy of an IgG quick test in detecting calves with failure of passive transfer was assessed. The test was carried out on 97 male calves, 38% of which were negative (IgG < 10 mg/mL). Morbidity and mortality due to infectious diseases were significantly higher in the negative group showing that the quick test is useful in identifying calves more susceptible to infectious disease. PMID:22043074

  16. Assessing the potential for passive radio sounding of Europa and Ganymede with RIME and REASON

    NASA Astrophysics Data System (ADS)

    Schroeder, Dustin M.; Romero-Wolf, Andrew; Carrer, Leonardo; Grima, Cyril; Campbell, Bruce A.; Kofman, Wlodek; Bruzzone, Lorenzo; Blankenship, Donald D.

    2016-12-01

    Recent work has raised the potential for Jupiter's decametric radiation to be used as a source for passive radio sounding of its icy moons. Two radar sounding instruments, the Radar for Icy Moon Exploration (RIME) and the Radar for Europa Assessment and Sounding: Ocean to Near-surface (REASON) have been selected for ESA and NASA missions to Ganymede and Europa. Here, we revisit the projected performance of the passive sounding concept and assess the potential for its implementation as an additional mode for RIME and REASON. We find that the Signal to Noise Ratio (SNR) of passive sounding can approach or exceed that of active sounding in a noisy sub-Jovian environment, but that active sounding achieves a greater SNR in the presence of quiescent noise and outperforms passive sounding in terms of clutter. We also compare the performance of passive sounding at the 9 MHz HF center frequency of RIME and REASON to other frequencies within the Jovian decametric band. We conclude that the addition of a passive sounding mode on RIME or REASON stands to enhance their science return by enabling sub-Jovian HF sounding in the presence of decametric noise, but that there is not a compelling case for implementation at a different frequency.

  17. Review on the epidemiology and dynamics of BSE epidemics.

    PubMed

    Ducrot, Christian; Arnold, Mark; de Koeijer, Aline; Heim, Dagmar; Calavas, Didier

    2008-01-01

    The paper describes how the comprehensive surveillance of bovine spongiform encephalopathy (BSE) and studies carried out on these data has enhanced our knowledge of the epidemiology of BSE. Around 7, 000 BSE cases were detected through the screening of about 50 million cattle with rapid tests in Europe. It confirmed that the clinical surveillance had a poor capacity to detect cases, and also showed the discrepancy of this passive surveillance efficiency between regions and production types (dairy/beef). Other risk factors for BSE were being in a dairy herd (three times more than beef), having a young age at first calving (for dairy cattle), being autumn-born (dairy and beef), and being in a herd with a very high milk yield. These findings focus the risk on the feeding regimen of calves/heifers. Several epidemiological studies across countries suggest that the feedborne source related to meat and bone meal (MBM) is the only substantiated route of infection - even after the feed ban -, while it is not possible to exclude maternal transmission or milk replacers as a source of some infections. In most European countries, the average age of the cases is increasing over time and the prevalence decreasing, which reflects the effectiveness of control measures. Consistent results on the trend of the epidemic were obtained using back-calculation modelling, the R(0) approach and Age-Period-Cohort models. Furthermore, active surveillance also resulted in the finding of atypical cases. These are distinct from previously found BSE and classified in two different forms based on biochemical characteristics; their prevalence is very low (36 cases up to 1st September 2007), affected animals were old and some of them displayed clinical signs. The origin and possibility of natural transmission is unknown.

  18. Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor.

    PubMed

    Koirala, Gyan Raj; Dhakal, Rajendra; Kim, Eun-Seong; Yao, Zhao; Kim, Nam-Young

    2018-04-03

    We present a microfabricated spiral-coupled passive resonator sensor realized through integrated passive device (IPD) technology for the sensitive detection and characterization of water-ethanol solutions. In order to validate the performance of the proposed device, we explicitly measured and analyzed the radio frequency (RF) characteristics of various water-ethanol solution compositions. The measured results showed a drift in the resonance frequency from 1.16 GHz for deionized (DI) water to 1.68 GHz for the solution containing 50% ethanol, whereas the rejection level given by the reflection coefficient decreased from -29.74 dB to -14.81 dB. The obtained limit of detection was 3.82% volume composition of ethanol in solution. The derived loaded capacitance was 21.76 pF for DI water, which gradually decreased to 8.70 pF for the 50% ethanol solution, and the corresponding relative permittivity of the solution decreased from 80.14 to 47.79. The dissipation factor increased with the concentration of ethanol in the solution. We demonstrated the reproducibility of the proposed sensor through iterative measures of the samples and the study of surface morphology. Successive measurement of different samples had no overlapping and had very minimum bias between RF characteristics for each measured sample. The surface profile for bare sensors was retained after the sample test, resulting a root mean square (RMS) value of 11.416 nm as compared to 10.902 nm for the bare test. The proposed sensor was shown to be a viable alternative to existing sensors for highly sensitive water-ethanol concentration detection.

  19. Fibre optic portable rail vehicle detector

    NASA Astrophysics Data System (ADS)

    Kepak, Stanislav; Cubik, Jakub; Zavodny, Petr; Hejduk, Stanislav; Nedoma, Jan; Davidson, Alan; Vasinek, Vladimir

    2016-12-01

    During track maintenance operations, the early detection of oncoming rail vehicles is critical for the safety of maintenance personnel. In addition, the detection system should be simple to install at the trackside by minimally qualified personnel. Fibre optic based sensor systems have the inherent advantages of being passive, unaffected by radio frequency interference (RFI) and suffering very low signal attenuation. Such a system therefore represents a good alternative to conventional approaches such as ultrasonic based sensor systems. The proposed system consists of one or more passive fibre trackside sensors and an x86 processing unit located at the work site. The solid fibre connection between sensors and processing unit eliminates the risk of RFI. In addition, the detection system sensors are easy to install with no requirement for electrical power at the sensor site. The system was tested on a tram line in Ostrava with the results obtained indicating the successful detection of all the trams in the monitoring windows using a single sensor. However, the platform allows flexibility in configuring multiple sensors where required by system users.

  20. Electrochemical and surface analysis of the Fe-Cr-Ru system in non-oxidizing acid solutions

    NASA Astrophysics Data System (ADS)

    Tjong, S. C.

    1990-03-01

    The effect of ruthenium addition on the spontaneous passivation behaviour of Fe-40Cr alloy in 0.5M H 2SO 4 and 0.5M HCl acid solutions has been studied. Auger and XPS techniques were also used to investigate the surface chemistries of the spontaneously passivated film. Electrochemical measurements indicate that the Fe-40Cr-0.1Ru and Fe-40Cr-0.2Ru alloys exhibit spontaneous passivation upon exposing them in both hydrochloric and sulphuric acid solutions from 25 to 85 ° C. However, the transition time for spontaneous passivation reduces dramatically with an increase in the ruthenium content and solution temperature. Furthermore, this transition time also decreases for the investigated alloys exposed in a less aggressive sulphuric acid solution. AES results show that ruthenium and chromium are enriched in the spontaneous passive films formed on the Fe-40Cr-0.1Ru alloy in both hydrochloric and sulphuric acid solutions at 25 °C, and also in the spontaneous passive film formed on the Fe-40Cr-0.2Ru alloy in hydrochloric acid solution at 25 ° C. AES does not detect the presence of ruthenium in the spontaneous passive film formed on the Fe-40Cr-0.2Ru alloy in sulphuric acid solution. However, XPS analysis shows that ruthenium and chromium are incorporated into the spontaneous passive films formed on the Fe-40Cr-0.1Ru and Fe-40Cr-0.2Ru alloys in both hydrochloric and sulphuric acid solutions as Ru 4+ and Cr 3+ species.

Top